WorldWideScience

Sample records for ndpk nm23 awd

  1. NM23 proteins: innocent bystanders or local energy boosters for CFTR?

    Science.gov (United States)

    Muimo, Richmond; Alothaid, Hani Mm; Mehta, Anil

    2018-03-01

    NM23 proteins NDPK-A and -B bind to the cystic fibrosis (CF) protein CFTR in different ways from kinases such as PKA, CK2 and AMPK or linkers to cell calcium such as calmodulin and annexins. NDPK-A (not -B) interacts with CFTR through reciprocal AMPK binding/control, whereas NDPK-B (not -A) binds directly to CFTR. NDPK-B can activate G proteins without ligand-receptor coupling, so perhaps NDPK-B's binding influences energy supply local to a nucleotide-binding site (NBD1) needed for CFTR to function. Curiously, CFTR (ABC-C7) is a member of the ATP-binding cassette (ABC) protein family that does not obey 'clan rules'; CFTR channels anions and is not a pump, regulates disparate processes, is itself regulated by multiple means and is so pleiotropic that it acts as a hub that orchestrates calcium signaling through its consorts such as calmodulin/annexins. Furthermore, its multiple partners make CFTR dance to different tunes in different cellular and subcellular locations as it recycles from the plasma membrane to endosomes. CFTR function in airway apical membranes is inhibited by smoking which has been dubbed 'acquired CF'. CFTR alone among family members possesses a trap for other proteins that it unfurls as a 'fish-net' and which bears consensus phosphorylation sites for many protein kinases, with PKA being the most canonical. Recently, the site of CFTR's commonest mutation has been proposed as a knock-in mutant that alters allosteric control of kinase CK2 by log orders of activity towards calmodulin and other substrates after CFTR fragmentation. This link from CK2 to calmodulin that binds the R region invokes molecular paths that control lumen formation, which is incomplete in the tracheas of some CF-affected babies. Thus, we are poised to understand the many roles of NDPK-A and -B in CFTR function and, especially lumen formation, which is defective in the gut and lungs of many CF babies.

  2. Phosphorylation of nm23/nucleoside diphosphate kinase by casein kinase 2 in vitro

    DEFF Research Database (Denmark)

    Engel, M; Issinger, O G; Lascu, I

    1994-01-01

    We have investigated phosphorylation of human nucleoside diphosphate kinase (NDPK) and of homologous NDPK from different species by human casein kinase 2 (CK-2). The human NDPK isotypes A and B were phosphorylated by CK-2 in vitro both when the purified proteins and total lysate of HL-60 leukemia...

  3. Regulation of heterotrimeric G-protein signaling by NDPK/NME proteins and caveolins: an update.

    Science.gov (United States)

    Abu-Taha, Issam H; Heijman, Jordi; Feng, Yuxi; Vettel, Christiane; Dobrev, Dobromir; Wieland, Thomas

    2018-02-01

    Heterotrimeric G proteins are pivotal mediators of cellular signal transduction in eukaryotic cells and abnormal G-protein signaling plays an important role in numerous diseases. During the last two decades it has become evident that the activation status of heterotrimeric G proteins is both highly localized and strongly regulated by a number of factors, including a receptor-independent activation pathway of heterotrimeric G proteins that does not involve the classical GDP/GTP exchange and relies on nucleoside diphosphate kinases (NDPKs). NDPKs are NTP/NDP transphosphorylases encoded by the nme/nm23 genes that are involved in a variety of cellular events such as proliferation, migration, and apoptosis. They therefore contribute, for example, to tumor metastasis, angiogenesis, retinopathy, and heart failure. Interestingly, NDPKs are translocated and/or upregulated in human heart failure. Here we describe recent advances in the current understanding of NDPK functions and how they have an impact on local regulation of G-protein signaling.

  4. YNK1, the yeast homolog of human metastasis suppressor NM23, is required for repair of UV radiation- and etoposide-induced DNA damage

    Energy Technology Data Exchange (ETDEWEB)

    Yang Mengmeng; Jarrett, Stuart G.; Craven, Rolf [Department of Molecular and Biomedical Pharmacology, College of Medicine, University of Kentucky, Lexington, KY 40536-0298 (United States); Kaetzel, David M. [Department of Molecular and Biomedical Pharmacology, College of Medicine, University of Kentucky, Lexington, KY 40536-0298 (United States)], E-mail: dmkaetz@uky.edu

    2009-01-15

    In humans, NM23-H1 is a metastasis suppressor whose expression is reduced in metastatic melanoma and breast carcinoma cells, and which possesses the ability to inhibit metastatic growth without significant impact on the transformed phenotype. NM23-H1 exhibits three enzymatic activities in vitro, each with potential to maintain genomic stability, a 3'-5' exonuclease and two kinases, nucleoside diphosphate kinase (NDPK), and protein histidine kinase. Herein we have investigated the potential contributions of NM23 proteins to DNA repair in the yeast, Saccharomyces cerevisiae, which contains a single NM23 homolog, YNK1. Ablation of YNK1 delayed repair of UV- and etoposide-induced nuclear DNA damage by 3-6 h. However, YNK1 had no impact upon the kinetics of MMS-induced DNA repair. Furthermore, YNK1 was not required for repair of mitochondrial DNA damage. To determine whether the nuclear DNA repair deficit manifested as an increase in mutation frequency, the CAN1 forward assay was employed. An YNK1 deletion was associated with increased mutation rates following treatment with either UV (2.6x) or MMS (1.6x). Mutation spectral analysis further revealed significantly increased rates of base substitution and frameshift mutations following UV treatment in the ynk1{delta} strain. This study indicates a novel role for YNK1 in DNA repair in yeast, and suggests an anti-mutator function that may contribute to the metastasis suppressor function of NM23-H1 in humans.

  5. YNK1, the yeast homolog of human metastasis suppressor NM23, is required for repair of UV radiation- and etoposide-induced DNA damage

    International Nuclear Information System (INIS)

    Yang Mengmeng; Jarrett, Stuart G.; Craven, Rolf; Kaetzel, David M.

    2009-01-01

    In humans, NM23-H1 is a metastasis suppressor whose expression is reduced in metastatic melanoma and breast carcinoma cells, and which possesses the ability to inhibit metastatic growth without significant impact on the transformed phenotype. NM23-H1 exhibits three enzymatic activities in vitro, each with potential to maintain genomic stability, a 3'-5' exonuclease and two kinases, nucleoside diphosphate kinase (NDPK), and protein histidine kinase. Herein we have investigated the potential contributions of NM23 proteins to DNA repair in the yeast, Saccharomyces cerevisiae, which contains a single NM23 homolog, YNK1. Ablation of YNK1 delayed repair of UV- and etoposide-induced nuclear DNA damage by 3-6 h. However, YNK1 had no impact upon the kinetics of MMS-induced DNA repair. Furthermore, YNK1 was not required for repair of mitochondrial DNA damage. To determine whether the nuclear DNA repair deficit manifested as an increase in mutation frequency, the CAN1 forward assay was employed. An YNK1 deletion was associated with increased mutation rates following treatment with either UV (2.6x) or MMS (1.6x). Mutation spectral analysis further revealed significantly increased rates of base substitution and frameshift mutations following UV treatment in the ynk1Δ strain. This study indicates a novel role for YNK1 in DNA repair in yeast, and suggests an anti-mutator function that may contribute to the metastasis suppressor function of NM23-H1 in humans

  6. Read-through transcript from NM23-H1 into the neighboring NM23-H2 gene encodes a novel protein, NM23-LV

    NARCIS (Netherlands)

    Valentijn, Linda J.; Koster, Jan; Versteeg, Rogier

    2006-01-01

    NM23-H1 and NM23-H2 are neighboring genes on chromosome 17q. They encode nucleoside diphosphate kinases that have additional roles in signal transduction, transcription, and apoptosis. NM23-H1 expression is a strong marker for prognosis and metastatic behavior in many tumor types. A new

  7. Fuel Efficiency in AWD-system

    OpenAIRE

    Fredriksson, Robert; Trkulja, Milovan

    2008-01-01

    This degree project has been made in cooperation with engineers working for GM Engineering/Saab Automobile AB in Trollhättan. The given name by Saab for the project is “Fuel efficiency improvements in All Wheel Drive(AWD)-system”. The main tasks of this thesis work were to investigate the size of the power losses in different parts on the propeller shaft, to design a computer program that calculates coordinates and angles on a propeller shaft and to investigate the possibilities to put togeth...

  8. Using alternate wetting & drying (AWD) rice flooding management

    Science.gov (United States)

    Research has shown that Mid-South producers can properly adapt and manage AWD, so as to reduce irrigation use while having no negative impact on grain yield. In addition to helping to reduce demand for groundwater, up to one gallon of diesel fuel may be saved for every acre-inch of groundwater that ...

  9. Role of Interaction and Nucleoside Diphosphate Kinase B in Regulation of the Cystic Fibrosis Transmembrane Conductance Regulator Function by cAMP-Dependent Protein Kinase A.

    Directory of Open Access Journals (Sweden)

    Lee A Borthwick

    Full Text Available Cystic fibrosis results from mutations in the cystic fibrosis transmembrane conductance regulator (CFTR, a cAMP-dependent protein kinase A (PKA and ATP-regulated chloride channel. Here, we demonstrate that nucleoside diphosphate kinase B (NDPK-B, NM23-H2 forms a functional complex with CFTR. In airway epithelia forskolin/IBMX significantly increases NDPK-B co-localisation with CFTR whereas PKA inhibitors attenuate complex formation. Furthermore, an NDPK-B derived peptide (but not its NDPK-A equivalent disrupts the NDPK-B/CFTR complex in vitro (19-mers comprising amino acids 36-54 from NDPK-B or NDPK-A. Overlay (Far-Western and Surface Plasmon Resonance (SPR analysis both demonstrate that NDPK-B binds CFTR within its first nucleotide binding domain (NBD1, CFTR amino acids 351-727. Analysis of chloride currents reflective of CFTR or outwardly rectifying chloride channels (ORCC, DIDS-sensitive showed that the 19-mer NDPK-B peptide (but not its NDPK-A equivalent reduced both chloride conductances. Additionally, the NDPK-B (but not NDPK-A peptide also attenuated acetylcholine-induced intestinal short circuit currents. In silico analysis of the NBD1/NDPK-B complex reveals an extended interaction surface between the two proteins. This binding zone is also target of the 19-mer NDPK-B peptide, thus confirming its capability to disrupt NDPK-B/CFTR complex. We propose that NDPK-B forms part of the complex that controls chloride currents in epithelia.

  10. Delivery of dsRNA through topical feeding for RNA interference in the citrus sap piercing-sucking hemipteran, Diaphorina citri.

    Science.gov (United States)

    Killiny, Nabil; Kishk, Abdelaziz

    2017-06-01

    RNA interference (RNAi) is a powerful means to study functional genomics in insects. The delivery of dsRNA is a challenging step in the development of RNAi assay. Here, we describe a new delivery method to increase the effectiveness of RNAi in the Asian citrus psyllid Diaphorina citri. Bromophenol blue droplets were topically applied to fifth instar nymphs and adults on the ventral side of the thorax between the three pairs of legs. In addition to video recordings that showed sucking of the bromophenol blue by the stylets, dissected guts turned blue indicating that the uptake was through feeding. Thus, we called the method topical feeding. We targeted the abnormal wing disc gene (awd), also called nucleoside diphosphate kinase (NDPK), as a reporter gene to prove the uptake of dsRNA via this method of delivery. Our results showed that dsRNA-awd caused reduction of awd expression and nymph mortality. Survival and lifespan of adults emerged from treated nymphs and treated adults were affected. Silencing awd caused wing malformation in the adults emerged from treated nymphs. Topical feeding as a delivery of dsRNA is highly efficient for both nymphs and adults. The described method could be used to increase the efficiency of RNAi in D. citri and other sap piercing-sucking hemipterans. © 2017 Wiley Periodicals, Inc.

  11. EVALUATION OF THE PROGNOSTIC VALUE OF nm23 GENE EXPRESSION IN BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    刘红; 毛慧生; 傅西林; 方志沂; 冯玉梅; 范宇; 李树玲

    2002-01-01

    Objective: To investigate the expression of nm23 gene and evaluate its prognostic value in breast cancer. Methods: nm23 expressions were detected in 101 breast cancer patients (group 1) by immunohistochemistry. RT-PCR and immunohistochemistry were used to measure expressions of nm23 gene in another 68 patients with breast cancer (group 2). Results: nm23 gene expression in group 1 was inversely associated with distant metastasis and lymph node metastasis (P<0.05). In 44 patients with negative lymph node, 9 cases progressed to distant metastasis, 7 of them (77.8%) showed low expression of nm23 gene (P<0.05). In 57 patients with positive lymph node, 24 our of 29 patients who had no distant metastasis (82.8%) expressed nm23 gene at high level (P<0.05). Meanwhile, there were 6 patients with distant metastasis in the group 2, all of thenm expressed nm23 gene mRNA at low level. Conclusion: The results showed that nm23 gene might play an independent role in predicting prognosis of breast cancer.

  12. Comparison of agrobacterium mediated wheat and barley transformation with nucleoside diphosphate kinase 2 (NDPK2) gene

    International Nuclear Information System (INIS)

    Waheed, U.; Shah, M.M.; Smedley, M.; Harwood, W.

    2016-01-01

    An efficient and reliable transformation system is imperative for improvement of important crop species like barley and wheat. Wheat transformation is complex due to larger genome size and polyploidy while barley has a limitation of genotypic dependency. The objective of current study was to compare the relative transformation efficiency of wheat and barley using specific expression vector pBRACT 214-NDPK2 constructed through gateway cloning carrying Nucleoside Diphosphate Kinase 2 (NDPK2) gene. The vector was used to compare the transformation response in both crops using immature embryos through Agrobacterium mediated transformation. Both wheat and barley showed different responses towards callus induction and regeneration. Immature embryos of 1.5 to 2 mm in diameter was found optimum for wheat callus induction while 1 to 1.5 mm for barley. Both embryogenic and non-embryogenic calli were found in wheat with significantly greater tendency for embryogenecity in barley. The overall regeneration response was found different for all transformed wheat and barley cultivars. Wheat cultivars showed good response initially that drastically slowed down in later stages with the exception of Fielder that reached to the green shoots with good roots. The barley transformed lines showed good regeneration response as compared to wheat. PCR analysis of putative transformants using genomic DNA showed a maximum of 27% transformation efficiency in barely. No true transformation response was obtained in all cultivars of wheat used in this study. The protocol developed for wheat and barley transformation will greatly be helpful in crop improvement programme through genetic engineering especially in diploid relatives of cereals. (author)

  13. NM23 protein expression in colorectal carcinoma using TMA (tissue microarray: association with metastases and survival

    Directory of Open Access Journals (Sweden)

    Levindo Alves de Oliveira

    2010-12-01

    Full Text Available CONTEXT: NM23, a metastasis suppressor gene, may be associated with prognosis in patients with colorectal carcinoma. OBJECTIVE: To analyze NM23 expression and its association with the presence of lymph node and liver metastases and survival in patients operated on for colorectal carcinoma. METHODS: One hundred thirty patients operated on for colorectal carcinoma were investigated. Tissue microarray blocks containing neoplastic tissue and tumor-adjacent non-neoplastic mucosa were obtained and analyzed by immunohistochemical staining using a monoclonal anti-NM23 antibody. Immunohistochemical expression was assessed using a semiquantitative scoring method, counting the percentage of stained cells. The results were compared regarding morphological and histological characteristics of the colorectal carcinoma, presence of lymph node and liver metastases, tumor staging, and patient survival. Statistical analysis was performed using the Mann-Whitney test, the Kruskal-Wallis test and Fisher's exact test. Survival analysis was performed using the Kaplan-Meier method and the log-rank test. RESULTS: NM23 expression was higher in colorectal carcinoma tissue than in adjacent non-neoplastic mucosa (P<0.0001. NM23 protein expression did not correlate with degree of cell differentiation (P = 0.57, vascular invasion (P = 0.85, lymphatic invasion (P = 0.41, perineural infiltration (P = 0.46, staging (P = 0.19, lymph node metastases (P = 0.08, or liver metastases (P = 0.59. Disease-free survival showed significant association (P = 0.01 with the intensity of NM23 protein immunohistochemical expression in colorectal carcinoma tissue, whereas overall survival showed no association with NM23 protein expression (P = 0.13. CONCLUSIONS: NM23 protein expression was higher in neoplastic colorectal carcinoma tissue than in adjacent non-neoplastic mucosa, showing no correlation with morphological aspects, presence of lymph node or liver metastases, colorectal carcinoma

  14. nm23 regulates decidualization through the PI3K-Akt-mTOR signaling pathways in mice and humans.

    Science.gov (United States)

    Zhang, Xue; Fu, Li-Juan; Liu, Xue-Qing; Hu, Zhuo-Ying; Jiang, Yu; Gao, Ru-Fei; Feng, Qian; Lan, Xi; Geng, Yan-Qing; Chen, Xue-Mei; He, Jun-Lin; Wang, Ying-Xiong; Ding, Yu-Bin

    2016-10-01

    Does nm23 have functional significance in decidualization in mice and humans? nm23 affects decidualization via the phosphoinositide 3 kinase/mammalian target of rapamycin (PI3K-Akt-mTOR) signaling pathways in mouse endometrial stromal cells (ESCs; mESCs) and human ESCs. The function of nm23 in suppressing metastasis has been demonstrated in a variety of cancer types. nm23 also participates in the control of DNA replication and cell proliferation and differentiation. We first analyzed the expression profile of nm23 in mice during early pregnancy (n = 6/group), pseudopregnancy (n = 6/group) and artificial decidualization (n = 6/group) and in humans during the menstrual cycle phases and the first trimester. We then used primary cultured mESCs and a human ESC line, T-HESC, to explore the hormonal regulation of nm23 and the roles of nm23 in in vitro decidualization, and as a possible mediator of downstream PI3K-Akt-mTOR signaling pathways. We evaluated the dynamic expression of nm23 in mice and humans using immunohistochemistry, western blot and real-time quantitative RT-PCR (RT-qPCR). Regulation of nm23 by steroid hormones was investigated in isolated primary mESCs and T-HESCs by western blot. The effect of nm23 knockdown (using siRNA) on ESC proliferation was analyzed by 5-ethynyl-2'-deoxyuridine staining (EdU) and proliferating cell nuclear antigen protein (PCNA) expression. The influence of nm23 expression on the differentiation of ESCs was determined by RT-qPCR using the mouse differentiation markers decidual/trophoblast PRL-related protein (dtprp, also named prl8a2) and prolactin family 3 subfamily c member 1 (prl3c1) and the human differentiation markers insulin-like growth factor binding protein 1 (IGFBP1) and prolactin (PRL). The effects of nm23 siRNA (si-nm23) and the PI3K inhibitor LY294002 on the downstream effects of nm23 on the PI3K-Akt-mTOR signaling pathway were estimated by western blot. NM23-M1 was specifically expressed in the decidual zone

  15. [Clinic significance of nm23, collage IV and PCNA expression in non-small cell lung cancer].

    Science.gov (United States)

    Yu, Q; Ma, L; Jing, S; Xu, Y; Geng, D

    2001-12-20

    To study the significance of nm23, collagen IV and PCNA expressions in non-small cell lung cancer. Expressions of the nm23, collagen IV and PCNA in 84 cases of non-small cell lung cancer were examined with SP immunohistochemical technique. Of the 84 cases, there were squamous cell carcinoma 42, adenocarcinoma 42, stage I 27, stage II 24, stage III 24, and stage IV 9. Statistical analysis was performed with Chi-Square test. Expressions of the nm23, collagen IV and PCNA in 84 cases of non-small cell lung cancer were 60. 7% ( 51/ 84) , 75. 0% ( 63/ 84) and 53. 6% ( 45/ 84) respectively. There was negative correlation between the lymph node metastasis and the expressions of nm23 and collagen IV in squamous cell carcinoma, and the expressions of collagen IV and PCNA were associated with tumor differentiation. No correlation was found between TNM stage and expressions of nm23, collagen IV and PCNA. The results indicate that nm23, collagen IV and PCNA participate the modulation of metastasis of non-small cell lung cancer and that they may be used to evaluate the potential of metastasis.

  16. [Adenovirus-mediated delivery of nm23-H1 gene inhibits growth of colorectal carcinoma cell line Lovo].

    Science.gov (United States)

    Wang, Qi; He, Xueling; Liu, Yan; Yin, Hailin

    2010-12-01

    This experimental study sought to find out the inhibitory effects of Ad-GFP-nm23-H1 on proliferation and metastasis of human colorectal carcinoma cell line Lovo, and, further, to gain an insight into some theoretical and methodical basis for instituting nm23-H1 gene therapy of cancers. MTT assay and Transwell chamber were used to detect the rates of proliferation and invasion as well as the adhesion of Lovo cells in vitro. The results demonstrated that the proliferation inhibition rates of Lovo cells treated with Ad-GFP-nm23-H1 of 10(10) PFU/ml, 10(9) PFU/ml and 10(8) PFU/ml were 84.9% +/- 1.51%, 48.5% +/- 7.23% and 22.5% +/- 5.47%, that the adherence inhibition rates of Lovo cells treated with Ad-GFP-nm23-H1 of 10(10) PFU/ml, 10(9) PFU/ml and 10(8) PFU/ml were 70.3% +/- 2.40%, 60.1% +/- 5.68% and 18.5% +/- 3.61%, and that the invasiveness inhibition rates of Lovo cells treated with Ad-GFP-nm23-H1 of 10(10) PFU/ml, 10(9) PFU/ml and 10(8) PFU/ml were 83.2% +/- 5.71%, 52.2% +/- 6.94% and 28.1% +/- 8.21%. These data suggested that Ad-GFP-nm23-H1 exerted significant inhibitory effects on the proliferation and metastasis of human colorectal carcinoma cell line Lovo in a dose-dependent way.

  17. Expression of nm23-H1 gene product in esophageal squamous cell carcinoma and its association with vessel invasion and survival

    International Nuclear Information System (INIS)

    Tomita, Masaki; Ayabe, Takanori; Matsuzaki, Yasunori; Edagawa, Masao; Maeda, Masayuki; Shimizu, Tetsuya; Hara, Masaki; Onitsuka, Toshio

    2001-01-01

    We assessed the nm23-H1 gene product expression and its relationship with lymphatic and blood vessel invasion in patients with esophageal squamous cell carcinoma. Formalin-fixed and paraffin-embedded tissue sections from 45 patients who were treated surgically were used in this study. Pathologists graded lymphatic and blood vessel invasion in each of the tissue samples. Expression of nm23-Hl gene product was determined using a specific monoclonal antibody. Expression of nm23-H1 gene product was present in 17 (37.8%) cases. We found an inverse correlation between nm23-H1 gene product expression and lymphatic vessel invasion, whereas no correlation between nm23-H1 gene product expression and blood vessel invasion. Overall survival rate was not different between nm23-H1 gene product positive and negative patients (p = 0.21). However, reduced expression of nm23-H1 gene product was associated with shorter overall survival in patients with involved lymph nodes (p < 0.05), but not in patients without involved lymph nodes (p = 0.87). In patients with esophageal squamous cell carcinoma, there appears to be an inverse relationship between nm23-H1 gene product expression and lymphatic vessel invasion. Furthermore, nm23-H1 gene product expression might be a prognostic marker in patients with involved lymph nodes. Our data does not demonstrate any correlation between nm23-H1 gene product expression and blood vessel invasion

  18. [Study on genetic instability of nm23H1 gene in Chinese with original gallbladder tumor].

    Science.gov (United States)

    Lu, Hai Ying; Zhang, Guo Qiang; Li, Ji Cheng

    2006-06-01

    The aim of this study was to examine the microsatellite instability (MSI) and loss of heterozygosity (LOH) of locus D17S396 on chromosome 17 and their influence on the expression of nm23H1 in gallbladder tumors, which may provide experimental basis for the tumor occurrence and metastasis. Techniques such as DNA extraction from formalin-fixed paraffin-embedded tissues, polymerase chain reaction-single strand conformation polymorphism (PCR-SSCP), ordinary silver stain were used to study MSI and LOH of locus D17S396. Envision immunohistochemistry and Leica-Qwin computer imaging techniques were used to assess the expression of gene nm23H1. In our experiment, the frequency of genetic instability of malignant gallbladder tumors was 42.55%, which was higher than that of gallbladder adenomas, while there were no genetic instability occurred in chronic cholecystitis tissue. The frequency of LOH seemed higher with the deteriorism of gallbladder tumor. Among 47 gallbladder carcinomas, the frequency of LOH and MSI were different between different differentiation cases (P gallbladder carcinoma, gallbladder adenoma and chronic cholecystitis tissue were different (P gallbladder carcinomas, the positive frequency of nm23H1 protein in LOH positive group was lower than that of LOH negative group (P gallbladder tumor. Both MSI and LOH of nm23H1 gene controlled the development of gallbladder tumor independently in different paths. MSI may be an early stage molecule marker of gallbladder carcinoma. LOH may be molecule marker for the deteriorism of gallbladder tissue, which could inhibit the expression of nm23H1 in local tissue of gallbladder carcinoma and endow it with high aggressive and poor prognosis. Increasing the amount of nm23H1 protein expression could effectively restrain gallbladder carcinoma metastasis and improve prognosis of patients.

  19. Clinical significance of altered nm23-H1, EGFR, RB and p53 expression in bilharzial bladder cancer

    International Nuclear Information System (INIS)

    Khaled, Hussein M; Bahnassy, Abeer A; Raafat, Amira A; Zekri, Abdel-Rahman N; Madboul, Maha S; Mokhtar, Nadia M

    2009-01-01

    Clinical characterization of bladder carcinomas is still inadequate using the standard clinico-pathological prognostic markers. We assessed the correlation between nm23-H1, Rb, EGFR and p53 in relation to the clinical outcome of patients with muscle invasive bilharzial bladder cancer (MI-BBC). nm23-H1, Rb, EGFR and p53 expression was assessed in 59 MI-BBC patients using immunohistochemistry and reverse transcription (RT-PCR) and was correlated to the standard clinico-pathological prognostic factors, patient's outcome and the overall survival (OS) rate. Overexpression of EGFR and p53 proteins was detected in 66.1% and 35.6%; respectively. Loss of nm23-H1and Rb proteins was detected in 42.4% and 57.6%; respectively. Increased EGFR and loss of nm23-H1 RNA were detected in 61.5% and 36.5%; respectively. There was a statistically significant correlation between p53 and EGFR overexpression (p < 0.0001), nm23 loss (protein and RNA), lymph node status (p < 0.0001); between the incidence of local recurrence and EGFR RNA overexpression (p= 0.003) as well as between the incidence of metastasis and altered Rb expression (p = 0.026), p53 overexpression (p < 0.0001) and mutation (p = 0.04). Advanced disease stage correlated significantly with increased EGFR (protein and RNA) (p = 0.003 & 0.01), reduced nm23-H1 RNA (p = 0.02), altered Rb (p = 0.023), and p53 overexpression (p = 0.004). OS rates correlated significantly, in univariate analysis, with p53 overexpression (p = 0.011), increased EGFR (protein and RNA, p = 0.034&0.031), nm23-H1 RNA loss (p = 0.021) and aberrations of ≥ 2 genes. However, multivariate analysis showed that only high EGFR overexpression, metastatic recurrence, high tumor grade and the combination of ≥ 2 affected markers were independent prognostic factors. nm23-H1, EGFR and p53 could be used as prognostic biomarkers in MI-BBC patients. In addition to the standard pathological prognostic factors, a combination of these markers (≥ 2) has

  20. Alternate wetting and drying (AWD) of paddy fields: A water-saving technology

    International Nuclear Information System (INIS)

    Salim, M.; Shehzad, F.D.

    2008-01-01

    Rice productivity in Pakistan is lower than in various rice-producing countries of the World. One of the major reasons of low productivity is the shortage of water. It is, therefore, imperative to increase water-use efficiency. Various studies in China and elsewhere have revealed that continuous flooding is not necessary for getting high yield of rice. In China, lot of effort has been made to develop water- saving rice-production technologies. The most important of these is alternate wetting and drying (AWD) of rice-fields, instead of keeping them continuously flooded or submerged. In the present article, salient advantages and disadvantages have been discussed. The advantages include less water-use for paddy-production, high paddy-productivity, and improvement in the environment, with enhanced efficiency of nutrient-use, better utilization of rainwater, less infestation/ population of insect pests. The technology may affect the grain-quality of Basmati rice in Pakistan. It is suggested that studies. on various aspects of the technology should be carried out, in various ecological zones and in different soil-types. The adoption of the technology may prove helpful to enhance rice-productivity and improve the rural economy in Pakistan. (author)

  1. Phorbol 12-myristate 13-acetate enhances nm23 gene expression in murine melanocytes but not in syngeneic B16-BL6 melanoma variants.

    Science.gov (United States)

    Huijzer, J C; McFarland, M; Niles, R M; Meadows, G G

    1996-03-01

    The nm23 gene has been described as a potential metastasis suppressor gene in certain rodent and human tumors. We previously demonstrated that tyrosine and phenylalanine restriction suppresses metastatic heterogeneity of B16-BL6 murine melanoma and selects for tumor variants with decreased metastatic potential. In this study, we investigated nm23 expression in the highly metastatic B16-BL6 (ND) melanoma, its nutritionally derived poorly metastatic (LT) variant, and the syngeneic non-tumorigenic Mel-ab melanocytes. No differences in nm23 expression were observed between ND and LT cells, and nm23 expression varied between different isolates. Previously, we showed that metastatic potential of 1-ND cells decreases and is not altered in 1-LT cells after prolonged in vitro cell passage; however, nm23 expression is equivalently increased by 2-fold. In 2-ND and 2-LT cells, expression of nm23 is not different at higher in vitro cell passage. Expression of nm23 decreased about 2-fold when phorbol 12-myristate 13-acetate (PMA) was removed from Mel-ab cells, which induces these cells to become quiescent. Although membrane-associated protein kinase C (PKC) activity decreased after prolonged PMA treatment in all cells, neither nm23 expression nor proliferation of ND and LT cells was affected by PMA. These data indicate that nm23 expression is related to proliferative activity rather than to the suppression of metastatic potential.

  2. Nm23-M2/NDP kinase B induces endogenous c-myc and nm23-M1/NDP kinase A overexpression in BAF3 cells. Both NDP kinases protect the cells from oxidative stress-induced death

    International Nuclear Information System (INIS)

    Arnaud-Dabernat, Sandrine; Masse, Karine; Smani, Moneim; Peuchant, Evelyne; Landry, Marc; Bourbon, Pierre-Marie; Le Floch, Renaud; Daniel, Jean-Yves; Larou, Monique

    2004-01-01

    The nm23 gene family encodes nucleoside diphosphate kinases (NDPKs) which supply the cell with (d)NTPs. The human NDPKB, also known as the PuF protein, binds the c-myc promoter and transactivates the c-myc protooncogene. We have now studied the effects of mouse NDPKA and NDPKB overexpression on endogenous c-myc transactivation in the mouse BAF3 and the rat PC12 cell lines. c-myc transcripts were found to be up-regulated by NDPKB only in the BAF3 line. This suggests that c-myc transcriptional control via NDPKB depends on the presence of cell-specific co-factors. Unexpectedly, NDPKB also induced NDPKA expression. This new effect was found in both cell lines, suggesting that NDPKB-dependent nm23-M1 gene transactivation requires cis and/or trans elements different from those involved in c-myc transactivation. Moreover, the BAF3 cell proliferation capacities were found to be independent of NDPKA or B cell contents. Interestingly, cell death induced by c-myc overexpression or H 2 O 2 exposure was decreased in nm23-transfected compared to control BAF3 cells. These data collectively suggest that NDPKs might improve cell survival by a mechanism coupling DNA repair and transcriptional regulation of genes involved in DNA damage response

  3. Extracellular Nm23H1 stimulates neurite outgrowth from dorsal root ganglia neurons in vitro independently of nerve growth factor supplementation or its nucleoside diphosphate kinase activity

    International Nuclear Information System (INIS)

    Wright, K.T.; Seabright, R.; Logan, A.; Lilly, A.J.; Khanim, F.; Bunce, C.M.; Johnson, W.E.B.

    2010-01-01

    Research highlights: → Extracellular Nm23H1 stimulates nerve growth. → Extracellular Nm23H1 provides pathfinding cues to growth cones. → The neurotrophic activity of Nm23H1 is independent of NDP kinase activity. → The neurotrophic activity of Nm23H1 is independent of NGF. -- Abstract: The nucleoside diphosphate (NDP) kinase, Nm23H1, is a highly expressed during neuronal development, whilst induced over-expression in neuronal cells results in increased neurite outgrowth. Extracellular Nm23H1 affects the survival, proliferation and differentiation of non-neuronal cells. Therefore, this study has examined whether extracellular Nm23H1 regulates nerve growth. We have immobilised recombinant Nm23H1 proteins to defined locations of culture plates, which were then seeded with explants of embryonic chick dorsal root ganglia (DRG) or dissociated adult rat DRG neurons. The substratum-bound extracellular Nm23H1 was stimulatory for neurite outgrowth from chick DRG explants in a concentration-dependent manner. On high concentrations of Nm23H1, chick DRG neurite outgrowth was extensive and effectively limited to the location of the Nm23H1, i.e. neuronal growth cones turned away from adjacent collagen-coated substrata. Nm23H1-coated substrata also significantly enhanced rat DRG neuronal cell adhesion and neurite outgrowth in comparison to collagen-coated substrata. These effects were independent of NGF supplementation. Recombinant Nm23H1 (H118F), which does not possess NDP kinase activity, exhibited the same activity as the wild-type protein. Hence, a novel neuro-stimulatory activity for extracellular Nm23H1 has been identified in vitro, which may function in developing neuronal systems.

  4. Extracellular Nm23H1 stimulates neurite outgrowth from dorsal root ganglia neurons in vitro independently of nerve growth factor supplementation or its nucleoside diphosphate kinase activity

    Energy Technology Data Exchange (ETDEWEB)

    Wright, K.T. [Keele University at the RJAH Orthopaedic Hospital, Oswestry, Shropshire (United Kingdom); Seabright, R.; Logan, A. [Neuropharmacology and Neurobiology, School of Clinical and Experimental Medicine, Birmingham University, Birmingham (United Kingdom); Lilly, A.J.; Khanim, F.; Bunce, C.M. [Biosciences, Birmingham University, Birmingham (United Kingdom); Johnson, W.E.B., E-mail: w.e.johnson@aston.ac.uk [Life and Health Sciences, Aston University, Birmingham (United Kingdom)

    2010-07-16

    Research highlights: {yields} Extracellular Nm23H1 stimulates nerve growth. {yields} Extracellular Nm23H1 provides pathfinding cues to growth cones. {yields} The neurotrophic activity of Nm23H1 is independent of NDP kinase activity. {yields} The neurotrophic activity of Nm23H1 is independent of NGF. -- Abstract: The nucleoside diphosphate (NDP) kinase, Nm23H1, is a highly expressed during neuronal development, whilst induced over-expression in neuronal cells results in increased neurite outgrowth. Extracellular Nm23H1 affects the survival, proliferation and differentiation of non-neuronal cells. Therefore, this study has examined whether extracellular Nm23H1 regulates nerve growth. We have immobilised recombinant Nm23H1 proteins to defined locations of culture plates, which were then seeded with explants of embryonic chick dorsal root ganglia (DRG) or dissociated adult rat DRG neurons. The substratum-bound extracellular Nm23H1 was stimulatory for neurite outgrowth from chick DRG explants in a concentration-dependent manner. On high concentrations of Nm23H1, chick DRG neurite outgrowth was extensive and effectively limited to the location of the Nm23H1, i.e. neuronal growth cones turned away from adjacent collagen-coated substrata. Nm23H1-coated substrata also significantly enhanced rat DRG neuronal cell adhesion and neurite outgrowth in comparison to collagen-coated substrata. These effects were independent of NGF supplementation. Recombinant Nm23H1 (H118F), which does not possess NDP kinase activity, exhibited the same activity as the wild-type protein. Hence, a novel neuro-stimulatory activity for extracellular Nm23H1 has been identified in vitro, which may function in developing neuronal systems.

  5. Enhanced broadband upconversion emission and 23 dB optical gain at 780 nm in Tm3+/Nd3+ codoped optical fiber

    International Nuclear Information System (INIS)

    Fan, Weiwei; Chen, Shuyue; Htein, Lin; Han, Won-Taek

    2015-01-01

    Maximum gain of 23 dB at 780 nm and a broadband optical gain with full width at half maximum (FWHM) of 88 nm (761–849 nm) were obtained from the Tm 3+ /Nd 3+ codoped fiber upon pumping at 1550 nm. The enhancement of the upconversion emission stretching from 730 to 970 nm was observed in the Tm 3+ /Nd 3+ codoped fiber due to the energy transfer from Tm 3+ to Nd 3+ ions. - Highlights: • We fabricated the Tm 3+ /Nd 3+ codoped silica based fiber. • The broadband upconversion emission was observed with 1550 nm pumping. • Maximum gain of 23 dB was observed at 780 nm from the Tm 3+ /Nd 3+ codoped fiber. • The gain bandwidth of the upconversion emission was largely increased due to energy transfer process

  6. NM23-H2 may play an indirect role in transcriptional activation of c-myc gene expression but does not cleave the nuclease hypersensitive element III1

    International Nuclear Information System (INIS)

    Dexheimer, Thomas S.; Carey, Steven S.; Zuohe, Song; Gokhale, Vijay M.; Hu, Xiaohui; Murata, Lauren B.; Maes, Estelle M.; Weichsel, Andrzej; Sun, Daekyu; Meuillet, Emmanuelle J.; Montfort, William R.; Hurley, Laurence H.

    2009-01-01

    The formation of G-quadruplex structures within the nuclease hypersensitive element (NHE) III 1 region of the c-myc promoter and the ability of these structures to repress c-myc transcription have been well established. However, just how these extremely stable DNA secondary structures are transformed to activate c-myc transcription is still unknown. NM23-H2/nucleoside diphosphate kinase B has been recognized as an activator of c-myc transcription via interactions with the NHE III 1 region of the c-myc gene promoter. Through the use of RNA interference, we confirmed the transcriptional regulatory role of NM23-H2. In addition, we find that further purification of NM23-H2 results in loss of the previously identified DNA strand cleavage activity, but retention of its DNA binding activity. NM23-H2 binds to both single-stranded guanine- and cytosine-rich strands of the c-myc NHE III 1 and, to a lesser extent, to a random single-stranded DNA template. However, it does not bind to or cleave the NHE III 1 in duplex form. Significantly, potassium ions and compounds that stabilize the G-quadruplex and i-motif structures have an inhibitory effect on NM23-H2 DNA-binding activity. Mutation of Arg 88 to Ala 88 (R88A) reduced both DNA and nucleotide binding but had minimal effect on the NM23-H2 crystal structure. On the basis of these data and molecular modeling studies, we have proposed a stepwise trapping-out of the NHE III 1 region in a single-stranded form, thus allowing single-stranded transcription factors to bind and activate c-myc transcription. Furthermore, this model provides a rationale for how the stabilization of the G-quadruplex or i-motif structures formed within the c-myc gene promoter region can inhibit NM23-H2 from activating c-myc gene expression.

  7. 2.3 Gbit/s underwater wireless optical communications using directly modulated 520 nm laser diode

    KAUST Repository

    Oubei, Hassan M.

    2015-07-30

    We experimentally demonstrate a record high-speed underwater wireless optical communication (UWOC) over 7 m distance using on-off keying non-return-to-zero (OOK-NRZ) modulation scheme. The communication link uses a commercial TO-9 packaged pigtailed 520 nm laser diode (LD) with 1.2 GHz bandwidth as the optical transmitter and an avalanche photodiode (APD) module as the receiver. At 2.3 Gbit/s transmission, the measured bit error rate of the received data is 2.23×10−4, well below the forward error correction (FEC) threshold of 2×10−3 required for error-free operation. The high bandwidth of the LD coupled with high sensitivity APD and optimized operating conditions is the key enabling factor in obtaining high bit rate transmission in our proposed system. To the best of our knowledge, this result presents the highest data rate ever achieved in UWOC systems thus far.

  8. Nitrogen losses and greenhouse gas emissions under different N and water management in a subtropical double-season rice cropping system.

    Science.gov (United States)

    Liang, Kaiming; Zhong, Xuhua; Huang, Nongrong; Lampayan, Rubenito M; Liu, Yanzhuo; Pan, Junfeng; Peng, Bilin; Hu, Xiangyu; Fu, Youqiang

    2017-12-31

    Nitrogen non-point pollution and greenhouse gas (GHG) emission are major challenges in rice production. This study examined options for both economic and environmental sustainability through optimizing water and N management. Field experiments were conducted to examine the crop yields, N use efficiency (NUE), greenhouse gas emissions, N losses under different N and water management. There were four treatments: zero N input with farmer's water management (N0), farmer's N and water management (FP), optimized N management with farmer's water management (OPT N ) and optimized N management with alternate wetting and drying irrigation (OPT N +AWD). Grain yields in OPT N and OPT N +AWD treatments increased by 13.0-17.3% compared with FP. Ammonia volatilization (AV) was the primary pathway for N loss for all treatments and accounted for over 50% of the total losses. N losses mainly occurred before mid-tillering. N losses through AV, leaching and surface runoff in OPT N were reduced by 18.9-51.6% compared with FP. OPT N +AWD further reduced N losses from surface runoff and leaching by 39.1% and 6.2% in early rice season, and by 46.7% and 23.5% in late rice season, respectively, compared with OPT N . The CH 4 emissions in OPT N +AWD were 20.4-45.4% lower than in OPT N and FP. Total global warming potential of CH 4 and N 2 O was the lowest in OPT N +AWD. On-farm comparison confirmed that N loss through runoff in OPT N +AWD was reduced by over 40% as compared with FP. OPT N and OPT N +AWD significantly increased grain yield by 6.7-13.9%. These results indicated that optimizing water and N management can be a simple and effective approach for enhancing yield with reduced environmental footprints. Copyright © 2017. Published by Elsevier B.V.

  9. Expression of alpha V integrin is modulated by Epstein-Barr virus nuclear antigen 3C and the metastasis suppressor Nm23-H1 through interaction with the GATA-1 and Sp1 transcription factors

    International Nuclear Information System (INIS)

    Choudhuri, Tathagata; Verma, Subhash C.; Lan, Ke; Robertson, Erle S.

    2006-01-01

    Epstein-Barr virus (EBV) is a lymphotrophic herpesvirus infecting most of the world's population. It is associated with a number of human lymphoid and epithelial tumors and lymphoproliferative diseases in immunocompromised patients. A subset of latent EBV antigens is required for immortalization of primary B-lymphocytes. The metastatic suppressor Nm23-H1 which is downregulated in human invasive breast carcinoma reduces the migration and metastatic activity of breast carcinoma cells when expressed from a heterologous promoter. Interestingly, the EBV nuclear antigen 3C (EBNA3C) reverses these activities of Nm23-H1. The alpha V integrins recognize a variety of ligands for signaling and are involved in cell migration and proliferation and also serve as major receptors for extracellular-matrix-mediated cell adhesion and migration. The goal of this study was to determine if Nm23-H1 and EBNA3C can modulate alpha V integrin expression and downstream activities. The results of our studies indicate that Nm23-H1 downregulates alpha V intregrin expression in a dose responsive manner. In contrast, EBNA3C can upregulate alpha V integrin expression. Furthermore, the study showed that the association of the Sp1 and GATA transcription factors with Nm23-H1 is required for modulation of the alpha V integrin activity. Thus, these results suggest a direct correlation between the alpha V integrin expression and the interaction of Nm23-H1 with EBNA3C

  10. Guidance for Large-scale Implementation of Alternate Wetting and Drying: A Biophysical Suitability Assessment

    Science.gov (United States)

    Sander, B. O.; Wassmann, R.; Nelson, A.; Palao, L.; Wollenberg, E.; Ishitani, M.

    2014-12-01

    The alternate wetting and drying (AWD) technology for rice production does not only save 15-30% of irrigation water, it also reduces methane emissions by up to 70%. AWD is defined by periodic drying and re-flooding of a rice field. Due to its high mitigation potential and its simplicity to execute this practice AWD has gained a lot of attention in recent years. The Climate and Clean Air Coalition (CCAC) has put AWD high on its agenda and funds a project to guide implementation of this technology in Vietnam, Bangladesh and Colombia. One crucial activity is a biophysical suitability assessment for AWD in the three countries. For this, we analyzed rainfall and soil data as well as potential evapotranspiration to assess if the water balance allows practicing AWD or if precipitation is too high for rice fields to fall dry. In my talk I will outline key factors for a successful large-scale implementation of AWD with a focus on the biophysical suitability assessment. The seasonal suitability maps that we generated highlight priority areas for AWD implementation and guide policy makers to informed decisions about meaningful investments in infrastructure and extension work.

  11. Alveolar macrophage accumulation rates, for 28 nm and 250 nm PSL, are mediated by separate mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Moss, O R; Wong, V A, E-mail: moss@thehamner.or [Hamner Institutes for Health Sciences, Research Triangle Park, NC 27509-2137 (United States)

    2009-02-01

    When macrophages accumulate 28 nm and 250 nm diameter polystyrene latex (PSL) beads, the accumulation rates should reflect differences in molecular and cellular function. We used a confocal microscope to measure the accumulation rates of nanoparticles by F344-rat-alveolar macrophages (approx25,000 cells adhered to a 0.7 cm{sup 2} surface). Over the cells were layered 0.1 ml of media, and 0.1 ml of media-with-beads. Fresh cells were introduced for each exposure scenario. The maximum possible individual macrophage exposures were as follows: 8x10{sup 6}, 8x10{sup 5}, and 8x10{sup 4} 28 nm beads per macrophage; and 8x10{sup 4} and 1.12x10{sup 4} 250 nm beads per macrophage. Accumulation rates were estimated over 23 minutes. The increase in bead accumulation-rate matched changes in bead-availability: 7x increase for 250 nm beads; 100x increase for 28 nm beads; and 700x increase for all bead availabilities. The maximum sustained 28 nm bead accumulation rate was > 30,000 /min (for 5 min). Increases in bead accumulation could be explained by two mechanisms: bead-diffusion; and, for the macrophage, macropinocytosis. Also for the highest concentrations of 28 nm beads, we saw a colligative threshold - possibly due to beads masking the cell surface or obstructing cellular mechanisms.

  12. Bismuth-doped fibre amplifier operating between 1600 and 1800 nm

    Energy Technology Data Exchange (ETDEWEB)

    Firstov, S V; Alyshev, S V; Riumkin, K E; Mel' kumov, M A; Dianov, E M [Fiber Optics Research Center, Russian Academy of Sciences, Moscow (Russian Federation); Khopin, V F; Gurjanov, A N [G.G.Devyatykh Institute of Chemistry of High-Purity Substances, Russian Academy of Sciences, Nizhnii Novgorod (Russian Federation)

    2015-12-31

    We report the first bismuth-doped fibre amplifier operating between 1600 and 1800 nm, which utilises bidirectional pumping (co-propagating and counter-propagating pump beams) by laser diodes at a wavelength of 1550 nm. The largest gain coefficient of the amplifier is 23 dB, at a wavelength of 1710 nm. It has a noise figure of 7 dB, 3-dB gain bandwidth of 40 nm and gain efficiency of 0.1 dB mW{sup -1}. (letters)

  13. Economic assessment of different mulches in conventional and water-saving rice production systems.

    Science.gov (United States)

    Jabran, Khawar; Hussain, Mubshar; Fahad, Shah; Farooq, Muhammad; Bajwa, Ali Ahsan; Alharrby, Hesham; Nasim, Wajid

    2016-05-01

    Water-saving rice production systems including alternate wetting and drying (AWD) and aerobic rice (AR) are being increasingly adopted by growers due to global water crises. Application of natural and artificial mulches may further improve water economy of water-saving rice production systems. Conventionally flooded rice (CFR) system has been rarely compared with AWD and AR in terms of economic returns. In this 2-year field study, we compared CFR with AWD and AR (with and without straw and plastic mulches) for the cost of production and economic benefits. Results indicated that CFR had a higher production cost than AWD and AR. However, application of mulches increased the cost of production of AWD and AR production systems where plastic mulch was expensive than straw mulch. Although the mulching increased the cost of production for AWD and AR, the gross income of these systems was also improved significantly. The gross income from mulched plots of AWD and AR was higher than non-mulched plots of the same systems. In conclusion, AWD and AR effectively reduce cost of production by economizing the water use. However, the use of natural and artificial mulches in such water-saving environments further increased the economic returns. The maximized economic returns by using straw mulch in water-saving rice production systems definitely have pragmatic implications for sustainable agriculture.

  14. Diode-pumped CW Nd:SGG laser at 1070 nm

    International Nuclear Information System (INIS)

    Liang, W; Sun, G C; Yu, X; Li, B Z; Jin, G Y

    2011-01-01

    We report for the first time (to our knowledge) a diode-pumped Nd:SGG laser emitting at 1070 nm. A power of 1.23 W at 1070 nm has been achieved in continuous-wave (CW) operation with a fiber-coupled laser diode emitting 18.2 W at 806 nm. Intracavity second-harmonic generation (SHG) in CW mode has also been demonstrated with a power of 328 mW at 535 nm by using a LiB 3 O 5 (LBO) nonlinear crystal. The green beam quality factor M 2 was less than 1.22. The green power stability was less 2.5% in 4 hour

  15. An EMMPRIN–γ-catenin–Nm23 complex drives ATP production and actomyosin contractility at endothelial junctions

    Science.gov (United States)

    Moreno, Vanessa; Gonzalo, Pilar; Gómez-Escudero, Jesús; Pollán, Ángela; Acín-Pérez, Rebeca; Breckenridge, Mark; Yáñez-Mó, María; Barreiro, Olga; Orsenigo, Fabrizio; Kadomatsu, Kenji; Chen, Christopher S.; Enríquez, José A.; Dejana, Elisabetta; Sánchez-Madrid, Francisco; Arroyo, Alicia G.

    2014-01-01

    ABSTRACT Cell–cell adhesions are important sites through which cells experience and resist forces. In endothelial cells, these forces regulate junction dynamics and determine endothelial barrier strength. We identify the Ig superfamily member EMMPRIN (also known as basigin) as a coordinator of forces at endothelial junctions. EMMPRIN localization at junctions correlates with endothelial junction strength in different mouse vascular beds. Accordingly, EMMPRIN-deficient mice show altered junctions and increased junction permeability. Lack of EMMPRIN alters the localization and function of VE-cadherin (also known as cadherin-5) by decreasing both actomyosin contractility and tugging forces at endothelial cell junctions. EMMPRIN ensures proper actomyosin-driven maturation of competent endothelial junctions by forming a molecular complex with γ-catenin (also known as junction plakoglobin) and Nm23 (also known as NME1), a nucleoside diphosphate kinase, thereby locally providing ATP to fuel the actomyosin machinery. These results provide a novel mechanism for the regulation of actomyosin contractility at endothelial junctions and might have broader implications in biological contexts such as angiogenesis, collective migration and tissue morphogenesis by coupling compartmentalized energy production to junction assembly. PMID:24994937

  16. An EMMPRIN-γ-catenin-Nm23 complex drives ATP production and actomyosin contractility at endothelial junctions.

    Science.gov (United States)

    Moreno, Vanessa; Gonzalo, Pilar; Gómez-Escudero, Jesús; Pollán, Ángela; Acín-Pérez, Rebeca; Breckenridge, Mark; Yáñez-Mó, María; Barreiro, Olga; Orsenigo, Fabrizio; Kadomatsu, Kenji; Chen, Christopher S; Enríquez, José A; Dejana, Elisabetta; Sánchez-Madrid, Francisco; Arroyo, Alicia G

    2014-09-01

    Cell-cell adhesions are important sites through which cells experience and resist forces. In endothelial cells, these forces regulate junction dynamics and determine endothelial barrier strength. We identify the Ig superfamily member EMMPRIN (also known as basigin) as a coordinator of forces at endothelial junctions. EMMPRIN localization at junctions correlates with endothelial junction strength in different mouse vascular beds. Accordingly, EMMPRIN-deficient mice show altered junctions and increased junction permeability. Lack of EMMPRIN alters the localization and function of VE-cadherin (also known as cadherin-5) by decreasing both actomyosin contractility and tugging forces at endothelial cell junctions. EMMPRIN ensures proper actomyosin-driven maturation of competent endothelial junctions by forming a molecular complex with γ-catenin (also known as junction plakoglobin) and Nm23 (also known as NME1), a nucleoside diphosphate kinase, thereby locally providing ATP to fuel the actomyosin machinery. These results provide a novel mechanism for the regulation of actomyosin contractility at endothelial junctions and might have broader implications in biological contexts such as angiogenesis, collective migration and tissue morphogenesis by coupling compartmentalized energy production to junction assembly. © 2014. Published by The Company of Biologists Ltd.

  17. 532 nm KTP激光治疗鲜红斑痣的自身对照研究%Efficacy and safety of 532 nm KTP laser in the treatment of port-wine stains

    Institute of Scientific and Technical Information of China (English)

    杨千里; 郑文渊; 卢忠

    2017-01-01

    Objective: To compare the efficacy and adverse reactions of 532 nm KTP laser and 595 nm pulsed dye laser in the treatment of port wine stain. Methods:The lesions of 18 patients were divided into two areas. One area was treated with 532 nm KTP laser and another area was treated with 595 nm pulsed dye la ̄ser, once every 2~3 months for 2~4 times. The safety and efficacy were evaluated after the treatment and in 2-3 months after the treatment. Results:There was no significant difference in the cure rate between 532 nm KTP laser and 595 nm pulsed dye laser. Some patients who were resistant to pulsed dye laser treatment were also sensitive to the treatment with 532 nm KTP laser. There were less pain and less purpura in the group of 532 nm KTP laser. Only one patient in each group developed hyperpigmentation. Conclusion: 532 nm KTP laser has similar efficacy to 595 nm pulsed dye laser and relatively less adverse reactions. It can be used as an alternative treatment of port wine stain.%目的::比较532 nm KTP激光与脉冲染料激光( PDL)对鲜红斑痣的疗效及安全性。方法:将18例鲜红斑痣患者的自身皮损随机分成KTP激光治疗区及PDL治疗区,分别予以532 nm KTP激光及595 nm PDL治疗,每2~3个月治疗一次,共2~4次。每次治疗前、后即刻及治疗后2~3个月对患者激光治疗后的皮损进行疗效及安全性评价。结果:532 nm KTP激光治疗组及595 nm PDL治疗组治疗后疗效均无显著差异。在一些既往曾接受PDL治疗疗效不佳的患者,经532 nm KTP 激光治疗后,皮损取得一定改善。532 nm KTP激光治疗组在治疗时疼痛程度及治疗后紫癜程度均显著低于595 nmPDL治疗组。两组均有1例色素沉着发生。结论:532 nm KTP激光治疗鲜红斑痣的疗效较好,不良反应少,安全性好,可以作为鲜红斑痣治疗的另一方案。

  18. Crystallization and preliminary X ray analysis of nucleoside diphosphate kinase 1 from T. cruzi

    International Nuclear Information System (INIS)

    Gomez Barroso, J.A.; Aguilar, C.F.; Miranda, M.R.; Pereira, C.A.

    2009-01-01

    Introduction: Trypanosoma cruzi is the etiologic agent of Chagas disease. The Nucleoside diphosphate kinases (NDPKs) are enzymes involved in energy management and nucleoside balance in the cell. T. cruzi TcNDPK1, a canonical isoform. The objective of this work is obtaining protein's crystals, diffract and process the data for tridimensional structure resolution. Materials and Methods: TcNDPK1 was expressed in E. coli as a fusion protein with Nterminal His-tag. TcNDPK1 was overexpressed and purified by FPLC. Crystallization was assayed by sitting drop and hanging drop vapor diffusion method. Crystals was frozen and diffracted on synchrotron x-ray radiation in Campinas (Brasil). The data set collected was reduced and merged using MOSFLM and SCALA programs. Results and Discussion: His-TcNDPK was overexpressed, purified and crystallized. The crystals are diffracted and collected the data to 3.5A. The crystals belong to the trigonal space group P3, with unit cell parameters a=127.94, b=127.84, c=275.49. Structure determination is under way. These results will provide relevant information that could be the first step in rational drug design for treating Chagas disease.(authors)

  19. The generation of a continuous-wave Nd:YVO4/LBO laser at 543 nm by direct in-band diode pumping at 888 nm

    International Nuclear Information System (INIS)

    Fu, S C; Wang, X; Chu, H

    2013-01-01

    We report the generation of a green laser at 543 nm by intracavity frequency doubling of the continuous-wave (cw) laser operation of a 1086 nm Nd:YVO 4 laser under 888 nm diode pumping into the emitting level 4 F 3/2 . An LiB 3 O 5 (LBO) crystal, cut for critical type I phase matching at room temperature, is used for the laser second-harmonic generation. At an incident pump power of 17.8 W, as high as 4.53 W cw output power at 543 nm is achieved. The optical-to-optical conversion efficiency is up to 25.4%, and the fluctuation of the green output power is better than 2.3% in a 30 min period. (paper)

  20. Frequency and risk factor of abdominal wound dehiscence

    International Nuclear Information System (INIS)

    Khan, M.N.S.; Naqvi, A.H.; Irshad, K.; Chaudhary, A.R.

    2004-01-01

    Objective: To find out the frequency of abdominal wound dehiscence (AWD) in a tertiary care hospital and the assessment of associated risk factors. Subjects and Methods: This study was carried out on 406 patients who underwent laparotomy for intra peritoneal procedure and complied with inclusion criteria. Demographic features were recorded and any complications documented. Results: Out of a total of 406 patients, 32 showed wound dehiscence giving an over all frequency of 7.8%. The male to female ratio was 2.8:1. The frequency was greater in males than in females. Majority patients suffered from an underlying malignancy. Malignant intestinal obstruction was the leading cause of wound dehiscence. Forty three patients had hypoalbuminemia(serum albumin <35 gm/l) and 09 of them had AWD. Emergency surgery showed a higher frequency of AWD(12.5%), as compared to elective surgery (18/143 and 14/263 respectively). Wound infection was a major contributor to AWD as out of 406, 76 patients developed infection and then 21 manifested AWD. Older age was also associated with greater frequency. The overall mortality of AWD in this study was 28.1 %. Conclusion: AWD still continues to be major post operative complication, with a high morbidity and mortality. The significant risk factors in this study were age more than 55 years, male gender, underlying malignancy, wound infection, jaundice, use of steroids, emergency surgery, uraemia and technique of closure. (author)

  1. Silencing abnormal wing disc gene of the Asian citrus psyllid, Diaphorina citri disrupts adult wing development and increases nymph mortality.

    Directory of Open Access Journals (Sweden)

    Ibrahim El-Shesheny

    Full Text Available Huanglongbing (HLB causes considerable economic losses to citrus industries worldwide. Its management depends on controlling of the Asian citrus Psyllid (ACP, the vector of the bacterium, Candidatus Liberibacter asiaticus (CLas, the causal agent of HLB. Silencing genes by RNA interference (RNAi is a promising tool to explore gene functions as well as control pests. In the current study, abnormal wing disc (awd gene associated with wing development in insects is used to interfere with the flight of psyllids. Our study showed that transcription of awd is development-dependent and the highest level was found in the last instar (5(th of the nymphal stage. Micro-application (topical application of dsRNA to 5(th instar of nymphs caused significant nymphal mortality and adult wing-malformation. These adverse effects in ACP were positively correlated with the amounts of dsRNA used. A qRT-PCR analysis confirmed the dsRNA-mediated transcriptional down-regulation of the awd gene. Significant down-regulation was required to induce a wing-malformed phenotype. No effect was found when dsRNA-gfp was used, indicating the specific effect of dsRNA-awd. Our findings suggest a role for awd in ACP wing development and metamorphosis. awd could serve as a potential target for insect management either via direct application of dsRNA or by producing transgenic plants expressing dsRNA-awd. These strategies will help to mitigate HLB by controlling ACP.

  2. Adults with dyslexia demonstrate large effects of crowding and detrimental effects of distractors in a visual tilt discrimination task.

    Directory of Open Access Journals (Sweden)

    Rizan Cassim

    Full Text Available Previous research has shown that adults with dyslexia (AwD are disproportionately impacted by close spacing of stimuli and increased numbers of distractors in a visual search task compared to controls [1]. Using an orientation discrimination task, the present study extended these findings to show that even in conditions where target search was not required: (i AwD had detrimental effects of both crowding and increased numbers of distractors; (ii AwD had more pronounced difficulty with distractor exclusion in the left visual field and (iii measures of crowding and distractor exclusion correlated significantly with literacy measures. Furthermore, such difficulties were not accounted for by the presence of covarying symptoms of ADHD in the participant groups. These findings provide further evidence to suggest that the ability to exclude distracting stimuli likely contributes to the reported visual attention difficulties in AwD and to the aetiology of literacy difficulties. The pattern of results is consistent with weaker and asymmetric attention in AwD.

  3. Nelikvedu alt ei vea / Jussa Nieminen

    Index Scriptorium Estoniae

    Nieminen, Jussa

    2016-01-01

    Võrdlustestis talveauto 2016: Audi A4 Lim. 2,0 TDI Quattro S tronic, BMW X1 xDrive20d A, Fiat 500X 2,0 140 MJet AWD AT Cross, Ford S-Max 2,0 TDCi 180 hj PowerShift Titanium AWD, Hyundai Tucson 1,6 T-GDI 7DCT Style, Kia Sportage 1,6T GT-Line 7DCT, Land Rover Discovery Sport 2,0 TD4 180 HSE A, Mazda CX-3 2,0 Skyactiv-G AWD Premium Plus AT, Mercedes-Benz GLC 250 d 4Matic, Renault Kadjar 1,6 dCi 4×4 Bose, Škoda Superb Combi 2,0 TDI SCR DSG 4×4 L&K, Ssangyong Korando D20 AWD 6AT, Subaru Levorg 1,6i GT-N CVT, Suzuki Vitara 1,4 Boosterjet 4WD S 6MT, Volvo V60 Cross Country D4 AWD Inscription A Võrdluseks esiveoline: Toyota Auris Touring Sports1,8 Hybrid e-CVT Active

  4. A multi-stakeholder partnership for the dissemination of alternate wetting and drying water-saving technology for rice farmers in the Philippines

    Directory of Open Access Journals (Sweden)

    Florencia G. Palis

    2017-09-01

    Full Text Available To address issues of water scarcity and food security for sustainable rice farming and increasing production, a water-saving technology called alternate wetting and drying (AWD was disseminated in the Philippines. This study assessed the impact of facilitating a network of stakeholders on disseminating AWD in irrigated rice systems in the Philippines. It used both qualitative and quantitative data collected from 2002 to 2012 in study sites in the country. Engaging multi-stakeholders in adaptive research, training, and dissemination facilitated the process of more interaction by partners. All partners joined a knowledge and dissemination alliance for scaling out AWD activities. This in turn effected a policy outcome, and the synergetic interactions of each partner within and outside the current network fast-tracked the dissemination process and adoption of AWD by farmers. The AWD practice resulted in an increase in irrigated rice area but not necessarily in rice production and farmers’ income. It also reduced labor and fuel consumption, especially in deep-well irrigation systems.

  5. 78 FR 72141 - New Mexico Disaster Number NM-00037

    Science.gov (United States)

    2013-12-02

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 13787 and 13788] New Mexico Disaster Number NM... Mexico (FEMA-4148-DR), dated 09/30/2013. Incident: Severe Storms and Flooding Incident Period: 07/23/2013... INFORMATION: The notice of the President's major disaster declaration for Private Non-Profit organizations in...

  6. 76 FR 81553 - New Mexico Disaster Number NM-00024

    Science.gov (United States)

    2011-12-28

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 12940 and 12941] New Mexico Disaster Number NM... Mexico (FEMA-4047-DR), dated 11/23/2011. Incident: Flooding. Incident Period: 08/19/2011 through 08/24... INFORMATION: The notice of the President's major disaster declaration for Private Non-Profit organizations in...

  7. Climate-Determined Suitability of the Water Saving Technology "Alternate Wetting and Drying" in Rice Systems: A Scalable Methodology demonstrated for a Province in the Philippines.

    Directory of Open Access Journals (Sweden)

    Andrew Nelson

    Full Text Available 70% of the world's freshwater is used for irrigated agriculture and demand is expected to increase to meet future food security requirements. In Asia, rice accounts for the largest proportion of irrigated water use and reducing or conserving water in rice systems has been a long standing goal in agricultural research. The Alternate Wetting and Drying (AWD technique has been developed to reduce water use by up to 30% compared to the continuously flooded conditions typically found in rice systems, while not impacting yield. AWD also reduces methane emissions produced by anaerobic archae and hence has applications for reducing water use and greenhouse gas emissions. Although AWD is being promoted across Asia, there have been no attempts to estimate the suitable area for this promising technology on a large scale. We present and demonstrate a spatial and temporal climate suitability assessment method for AWD that can be widely applied across rice systems in Asia. We use a simple water balance model and easily available spatial and temporal information on rice area, rice seasonality, rainfall, potential evapotranspiration and soil percolation rates to assess the suitable area per season. We apply the model to Cagayan province in the Philippines and conduct a sensitivity analysis to account for uncertainties in soil percolation and suitability classification. As expected, the entire dry season is climatically suitable for AWD for all scenarios. A further 60% of the wet season area is found suitable contradicting general perceptions that AWD would not be feasible in the wet season and showing that spatial and temporal assessments are necessary to explore the full potential of AWD.

  8. Testing climate-smart irrigation strategies to reduce methane emissions from rice fields

    Science.gov (United States)

    Runkle, B.; Suvocarev, K.; Reba, M. L.

    2017-12-01

    Approximately 11% of the global 308 Tg CH4 anthropogenic emissions are currently attributed to rice cultivation. In this study, the impact of water conservation practices on rice field CH4 emissions was evaluated in Arkansas, the leading state in US rice cultivation. While conserving water, the Alternate Wetting and Drying (AWD) irrigation practice can also reduce CH4 emissions through the deliberate, periodic introduction of aerobic conditions. Seasonal CH4emissions from a pair of adjacent, production-sized rice fields were estimated and compared during the 2015 to 2017 growing seasons using the eddy covariance method on each field. The fields were alternately treated with continuous flood (CF) and AWD irrigation. In 2015, the seasonal cumulative carbon losses by CH4 emission were 30.3 ± 6.3 and 141.9 ± 8.6 kg CH4-C ha-1 for the AWD and CF treatments, respectively. Data from 2016 and 2017 will be analyzed and shown within this presentation; an initial view demonstrates consistent findings to 2015. When accounting for differences in field conditions and soils, the AWD practice is attributable to a 36-51% reduction in seasonal emissions. The substantial decrease in CH4 emissions by AWD supports previous chamber-based research and offers strong evidence for the efficacy of AWD in reducing CH4 emissions in Arkansas rice production. The AWD practice has enabled the sale of credits for carbon offsets trading and this new market could encourage CH4 emissions reductions on a national scale. These eddy covariance towers are being placed into a regional perspective including crop and forest land in the three states comprising the Mississippi Delta: Arkansas, Mississippi, and Louisiana.

  9. Diode-pumped thin-disk Nd:GdVO4 laser at 893 nm

    International Nuclear Information System (INIS)

    Li, Y L; Fu, X H; Wang, A G

    2011-01-01

    We report for the first time a Nd:GdVO 4 laser operating in a continuous wave (CW) on the quasi-three-level laser at 893 nm, based on the 4 F 3/2 – 4 I 9/2 transition, generally used for a 912 nm emission. The use of a pump module with 16 passes through the crystal allowed the realization of a Nd:GdVO 4 thin-disk laser with 157 mW of CW output power at 893 nm. Moreover, intracavity second-harmonic generation (SHG) has also been achieved with a power of 23 mW at 447 nm by using a BiB 3 O 6 (BiBO) nonlinear crystal

  10. High-power frequency-stabilized laser for laser cooling of metastable helium at 389 nm

    NARCIS (Netherlands)

    Koelemeij, J.C.J.; Hogervorst, W.; Vassen, W.

    2005-01-01

    A high-power, frequency-stabilized laser for cooling of metastable helium atoms using the 2 S13 →3 P23 transition at 389 nm has been developed. The 389 nm light is generated by frequency doubling of a titanium:sapphire laser in an external enhancement cavity containing a lithium-triborate nonlinear

  11. Diode-side-pumped 131 W, 1319 nm single-wavelength cw Nd:YAG laser.

    Science.gov (United States)

    Haiyong, Zhu; Ge, Zhang; Chenghui, Huang; Yong, Wei; Lingxiong, Huang; Jing, Chen; Weidong, Chen; Zhenqiang, Chen

    2007-01-20

    A diode-side-pumped high-power 1319 nm single-wavelength Nd:YAG continuous wave (cw) laser is described. Through reasonable coating design of the cavity mirrors, the 1064 nm strongest line as well as the 1338 nm one have been successfully suppressed. The laser output powers corresponding to four groups of different output couplers operating at 1319 nm single wavelength have been compared. The output coupler with the transmission T=5.3% has the highest output power, and a 131 W cw output power was achieved at the pumping power of 555 W. The optical-optical conversion efficiency is 23.6%, and the slope efficiency is 46%. The output power is higher than the total output power of the dual-wavelength laser operating at 1319 nm and 1338 nm in the experiment.

  12. Short-term clinical outcomes of laser supported periodontal treatment concept using Er,Cr:YSGG (2780nm) and diode (940 nm): a pilot study

    Science.gov (United States)

    Odor, Alin A.; Violant, Deborah; Badea, Victoria; Gutknecht, Norbert

    2016-03-01

    Backgrounds: Er,Cr:YSGG (2780nm) and diode (940 nm) lasers can be used adjacent to the conventional periodontal treatment as minimally invasive non-surgical devices. Aim: To describe the short-term clinical outcomes by combining Er,Cr:YSGG (2780nm) and diode 940 nm lasers in non-surgical periodontal treatment. Materials and methods: A total of 10 patients with periodontal disease (mild, moderate, severe) - 233 teeth and 677 periodontal pockets ranging from 4 mm to 12 mm - were treated with Er,Cr:YSGG (2780nm) and diode (940 nm) lasers in adjunct to manual and piezoelectric scaling and root planning (SRP). Periodontal parameters such as mean probing depth (PD), mean clinical attachment level (CAL) and mean bleeding on probing (BOP) were evaluated at baseline and 6 months after the laser treatment using an electronic periodontal chart. Results: At baseline, the mean PD was 4.06 ± 1.06 mm, mean CAL was 4.56 ± 1.43 mm, and mean BOP was 43.8 ± 23.84 %. At 6 months after the laser supported periodontal treatments the mean PD was 2.6 ± 0.58 mm (p laser wavelengths in adjunct to SRP offers significant improvements of periodontal clinical parameters such as PD, CAL and BOP. Keywords: Laser supported periodontal treatment concept, Er,Cr:YSGG and diode 940nm lasers, Scaling and root planning, Minimally invasive non-surgical device

  13. Studies on nanosecond 532nm and 355nm and ultrafast 515nm and 532nm laser cutting super-hard materials

    Science.gov (United States)

    Zhang, Jie; Tao, Sha; Wang, Brian; Zhao, Jay

    2017-02-01

    In this paper, micro-processing of three kinds of super-hard materials of poly-crystal diamond (PCD)/tungsten-carbide (WC), CVD-diamond and cubic boron nitride (CNB) has been systematically studied using nanosecond laser (532nm and 355nm), and ultrafast laser (532nm and 515nm). Our purpose is to investigate a full laser micro-cutting solution to achieve a ready-to-use cutting tool insert (CTI). The results show a clean cut with little burns and recasting at edge. The cutting speed of 2-10mm/min depending on thickness was obtained. The laser ablation process was also studied by varying laser parameters (wavelength, pulse width, pulse energy, repetition rate) and tool path to improve cutting speed. Also, studies on material removal efficiency (MRE) of PCD/WC with 355nm-ns and 515nm-fs laser as a function of laser fluence show that 355nm-ns laser is able to achieve higher MRE for PCD and WC. Thus, ultrafast laser is not necessarily used for superhard material cutting. Instead, post-polishing with ultrafast laser can be used to clean cutting surface and improve smoothness.

  14. Impairment of metabolic capacities in copper and cadmium contaminated wild yellow perch (Perca flavescens)

    International Nuclear Information System (INIS)

    Couture, Patrice; Rajender Kumar, Puja

    2003-01-01

    This study examined variations in resting oxygen consumption rate (ROCR), post-exercise oxygen consumption rate, relative scope for activity (RSA), liver and muscle aerobic and anaerobic capacities (using citrate synthase (CS) and lactate dehydrogenase, respectively, as indicators), and tissue biosynthetic capacities (using nucleoside diphosphate kinase (NDPK) as an indicator), in wild yellow perch from four lakes varying in copper (Cu) and cadmium (Cd) contamination. Liver Cu and Cd concentrations largely reflected environmental contamination and were positively correlated with liver protein concentrations and NDPK activities. Our results suggest that metal contamination leads to an upregulation of liver protein metabolism, presumably at least in part for the purpose of metal detoxification. In contrast, muscle NDPK activities decreased with increasing liver Cd concentrations and NDPK activities. There was a 25% decrease in ROCR for a doubling of liver Cu concentrations and a 42% decrease in RSA for a doubling of liver Cd concentrations in the range studied. Cu contamination was also associated with lower muscle CS activities. Our results support previous findings of impaired aerobic capacities in the muscle of metal-contaminated fish, and demonstrate that this impairment is also reflected in aerobic capacities of whole fish. The evidence presented suggests that mitochondria may be primary targets for inhibition by Cu, and that Cd may reduce gill respiratory capacity. Muscle aerobic and anaerobic capacities were inversely related. This work indicates that metal exposure of wild yellow perch leads to a wide range of disturbances in metabolic capacities

  15. Septin 7 reduces nonmuscle myosin IIA activity in the SNAP23 complex and hinders GLUT4 storage vesicle docking and fusion

    Energy Technology Data Exchange (ETDEWEB)

    Wasik, Anita A.; Dumont, Vincent [Department of Pathology, University of Helsinki, 00014 Helsinki (Finland); Tienari, Jukka [Department of Pathology, University of Helsinki and Helsinki University Hospital, 00290 Helsinki, 05850 Hyvinkää (Finland); Nyman, Tuula A. [Institute of Biotechnology, University of Helsinki, 00014 Helsinki (Finland); Fogarty, Christopher L.; Forsblom, Carol; Lehto, Markku [Folkhälsan Institute of Genetics, Folkhälsan Research Center, 00290 Helsinki (Finland); Abdominal Center Nephrology, University of Helsinki and Helsinki University Hospital, 000290 Helsinki (Finland); Diabetes& Obesity Research Program, Research Program´s Unit, 00014 University of Helsinki (Finland); Lehtonen, Eero [Department of Pathology, University of Helsinki, 00014 Helsinki (Finland); Laboratory Animal Centre, University of Helsinki, 00014 Helsinki (Finland); Groop, Per-Henrik [Folkhälsan Institute of Genetics, Folkhälsan Research Center, 00290 Helsinki (Finland); Abdominal Center Nephrology, University of Helsinki and Helsinki University Hospital, 000290 Helsinki (Finland); Diabetes& Obesity Research Program, Research Program´s Unit, 00014 University of Helsinki (Finland); Baker IDI Heart & Diabetes Institute, 3004 Melbourne (Australia); Lehtonen, Sanna, E-mail: sanna.h.lehtonen@helsinki.fi [Department of Pathology, University of Helsinki, 00014 Helsinki (Finland)

    2017-01-15

    Glomerular epithelial cells, podocytes, are insulin responsive and can develop insulin resistance. Here, we demonstrate that the small GTPase septin 7 forms a complex with nonmuscle myosin heavy chain IIA (NMHC-IIA; encoded by MYH9), a component of the nonmuscle myosin IIA (NM-IIA) hexameric complex. We observed that knockdown of NMHC-IIA decreases insulin-stimulated glucose uptake into podocytes. Both septin 7 and NM-IIA associate with SNAP23, a SNARE protein involved in GLUT4 storage vesicle (GSV) docking and fusion with the plasma membrane. We observed that insulin decreases the level of septin 7 and increases the activity of NM-IIA in the SNAP23 complex, as visualized by increased phosphorylation of myosin regulatory light chain. Also knockdown of septin 7 increases the activity of NM-IIA in the complex. The activity of NM-IIA is increased in diabetic rat glomeruli and cultured human podocytes exposed to macroalbuminuric sera from patients with type 1 diabetes. Collectively, the data suggest that the activity of NM-IIA in the SNAP23 complex plays a key role in insulin-stimulated glucose uptake into podocytes. Furthermore, we observed that septin 7 reduces the activity of NM-IIA in the SNAP23 complex and thereby hinders GSV docking and fusion with the plasma membrane. - Highlights: • Septin 7, nonmuscle myosin heavy chain IIA (NMHC-IIA) and SNAP23 form a complex. • Knockdown of septin 7 increases NM-IIA activity in the SNAP23 complex. • Insulin decreases septin 7 level and increases NM-IIA activity in the SNAP23 complex. • Septin 7 hinders GSV docking/fusion by reducing NM-IIA activity in the SNAP23 complex.

  16. Septin 7 reduces nonmuscle myosin IIA activity in the SNAP23 complex and hinders GLUT4 storage vesicle docking and fusion

    International Nuclear Information System (INIS)

    Wasik, Anita A.; Dumont, Vincent; Tienari, Jukka; Nyman, Tuula A.; Fogarty, Christopher L.; Forsblom, Carol; Lehto, Markku; Lehtonen, Eero; Groop, Per-Henrik; Lehtonen, Sanna

    2017-01-01

    Glomerular epithelial cells, podocytes, are insulin responsive and can develop insulin resistance. Here, we demonstrate that the small GTPase septin 7 forms a complex with nonmuscle myosin heavy chain IIA (NMHC-IIA; encoded by MYH9), a component of the nonmuscle myosin IIA (NM-IIA) hexameric complex. We observed that knockdown of NMHC-IIA decreases insulin-stimulated glucose uptake into podocytes. Both septin 7 and NM-IIA associate with SNAP23, a SNARE protein involved in GLUT4 storage vesicle (GSV) docking and fusion with the plasma membrane. We observed that insulin decreases the level of septin 7 and increases the activity of NM-IIA in the SNAP23 complex, as visualized by increased phosphorylation of myosin regulatory light chain. Also knockdown of septin 7 increases the activity of NM-IIA in the complex. The activity of NM-IIA is increased in diabetic rat glomeruli and cultured human podocytes exposed to macroalbuminuric sera from patients with type 1 diabetes. Collectively, the data suggest that the activity of NM-IIA in the SNAP23 complex plays a key role in insulin-stimulated glucose uptake into podocytes. Furthermore, we observed that septin 7 reduces the activity of NM-IIA in the SNAP23 complex and thereby hinders GSV docking and fusion with the plasma membrane. - Highlights: • Septin 7, nonmuscle myosin heavy chain IIA (NMHC-IIA) and SNAP23 form a complex. • Knockdown of septin 7 increases NM-IIA activity in the SNAP23 complex. • Insulin decreases septin 7 level and increases NM-IIA activity in the SNAP23 complex. • Septin 7 hinders GSV docking/fusion by reducing NM-IIA activity in the SNAP23 complex.

  17. Continuous-wave laser at 440 nm based on frequency-doubled diode-pumped Nd:GdVO(4) crystal.

    Science.gov (United States)

    Castaing, Marc; Balembois, François; Georges, Patrick

    2008-09-01

    We present for the first time, to the best of our knowledge, a frequency-doubled Nd:GdVO(4) laser operating in a cw on the pure three-level laser line at 880 nm. We obtained 300 mW at 440 nm for 23 W of incident pump power at 808 nm. Moreover, with a 25% output coupler we obtained a cw power of 1.9 W at the fundamental wavelength at 880 nm.

  18. Modelling Water Flow through Paddy Soils under Alternate Wetting and Drying Irrigation Practice

    Science.gov (United States)

    Shekhar, S.; Mailapalli, D. R.; Das, B. S.; Raghuwanshi, N. S.

    2017-12-01

    Alternate wetting and drying (AWD) irrigation practice in paddy cultivation requires an optimum soil moisture stress (OSMS) level at which irrigation water savings can be maximized without compromising the yield reduction. Determining OSMS experimentally is challenging and only possible with appropriate modeling tools. In this study, field experiments on paddy were conducted in thirty non-weighing type lysimeters during dry seasons of 2016 and 2017. Ten plots were irrigated using continuous flooding (CF) and the rest were irrigated with AWD practice at 40mb and 75mb soil moisture stress levels. Depth of ponding and soil suction at 10, 40 and 70 cm from the soil surface were measured daily from all lysimeter plots. The measured field data were used in calibration and validation of Hydrus-1D model and simulated the water flow for both AWD and CF plots. The Hydrus-1D is being used to estimate OSMS for AWD practice and compared the seasonal irrigation water input and deep percolation losses with CF practice.

  19. KOEFISIEN TANAMAN PADI SAWAH PADA SISTEM IRIGASI HEMAT AIR Crop Coefficient for Paddy Rice Field under Water Saving Irrigation Systems

    Directory of Open Access Journals (Sweden)

    Joko Sujono

    2012-05-01

    Full Text Available Traditional irrigation for paddy rice is the leading of consumer of water, about 80 % of the water resource availabilityused for irrigation purpose. This phenomenon is related to the way how to estimate the crop water requirement where crop coefficient for paddy rice (k (Prosida is always greater than one starting from planting up to nearly harvesting. In this research, a number of water saving irrigations (WSI systems for paddy rice cultivation using pots such asalternate wetting and drying (AWD, shallow water depth with wetting and drying (SWD, semi-dry cultivation (SDC, system of rice intensification (SRI, and  AWD with mulch (AWD-Mul were applied. The amount of irrigated water and when it should be irrigated depend on evapotranspiration rate, soil moisture condition and the WSI system used. For this purpose, daily measurement of the pot weight was carried out. Crop coefficient (k  is then caluculated as a cratio between crop and reference evapotranspiration computed using Penman-Montheit  method. Results show that up to 45 days after transplanting, the k of WSI treatments were around half of the k (Prosida values currently used for computing the water requirement, whereas at the productive stage the k of WSI systems were relatively equal (AWD, SDC to or greater (SRI, SWD than the k (Prosida. Based on the the k values, the AWD and the SDC systems could save much water compared to the SRI or the SWD. Water saving could be increased by applying the AWD with mulch. ABSTRAK Irigasi padi sawah dengan sistem tradisional merupakan sistem irigasi  yang boros air, hampir 80 % sumber air yang ada untuk irigasi. Hal ini tidak terlepas dari perhitungan kebutuhan air tanaman dengan nilai koefisien tanaman (k menurut Standar Perencanaan Irigasi (Prosida selalu lebih besar dari satu mulai dari tanam hingga menjelang panen.Dalam penelitian ini beberapa metoda budidaya padi hemat air seperti alternate wetting and drying (AWD, shallow water depth

  20. Dust Explosion Characteristics of Agglomerated 35 nm and 100 nm Aluminum Particles

    Directory of Open Access Journals (Sweden)

    Hong-Chun Wu

    2010-01-01

    Full Text Available In the experiment, nanoparticles of 35 nm Al and 100 nm Al powders, respectively, formed particles with average sizes of 161 nm and 167 nm in agglomeration. The characteristics of dust cloud explosions with the two powder sizes, 35 nm and 100 nm, revealed considerable differences, as shown here: (dp/dtmax-35 nm = 1254 bar/s, (dp/dtmax-100 nm = 1105 bar/s; Pmax-35 nm = 7.5 bar, Pmax-100 nm = 12.3 bar, and MEC-35 nm = 40 g/m3, MEC-100 nm = 50 g/m3. The reason of Pmax-35 nm value is smaller than Pmax-100 nm may be due to agglomeration. From an analysis of the explosive residue, the study found that nanoparticles of 35 nm Al powder became filamentous strands after an explosion, where most of 100 nm Al nanoparticles maintained a spherical structure, This may be because the initial melting temperature of 35 nm Al is 435.71°C, while that for 100 nm Al is 523.58°C, higher by 87.87°C. This study discovered that explosive property between the 35 nm Al and 100 nm Al powders after agglomeration were different.

  1. Influence of Seed Priming on Performance and Water Productivity of Direct Seeded Rice in Alternating Wetting and Drying

    Directory of Open Access Journals (Sweden)

    Hafeez Ur Rehman

    2015-07-01

    Full Text Available Direct seeded rice is promising alternative to traditional transplanting, but requires appropriate crop and water management to maintain yield performance and achieve high water productivity. Present study evaluated the effect of seed priming and irrigation on crop establishment, tillering, agronomic traits, paddy yield, grain quality and water productivity of direct seeded rice in alternate wetting and drying (DSR-AWD in comparison with direct seeded rice at field capacity (DSR-FC. Seed priming treatments were osmo-priming with KCl (2.2%, CaCl2 (2.2% and moringa leaf extracts (MLE, 3.3% including hydro-priming as control. Among the treatments, seed osmo-primed with MLE emerged earlier and had higher final emergence, followed by osmo-priming with CaCl2. Tillering emergence rate and number of tillers per plant were the highest for seed priming with CaCl2 in DSR-AWD. Total productive and non-productive tillers, panicle length, biological and grain yields, harvest index were highest for seed priming with MLE or CaCl2 in DSR-AWD. Similarly, grain quality, estimated in terms of normal grains, abortive and chalky grains, was also the highest in DSR-AWD with MLE osmo-priming. Benefit cost ratio and water productivity was also the highest in DSR-AWD for seed priming with MLE. In conclusion, seed priming with MLE or CaCl2 can be successfully employed to improve the direct seeded rice performance when practiced with alternate wetting and drying irrigation.

  2. Unigene BLAST: CBRC-HSAP-23-0072 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-HSAP-23-0072 gnl|UG|Hs#S1730560 Homo sapiens opsin 1 (cone pigments), medium-wave-sensitive (color blin...dness, deutan) (OPN1MW), mRNA /cds=p(1,1095) /gb=NM_000513 /gi=4503964 /ug=Hs.247787 /len=1095 0.0 100% ...

  3. Unigene BLAST: CBRC-HSAP-23-0073 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-HSAP-23-0073 gnl|UG|Hs#S1730560 Homo sapiens opsin 1 (cone pigments), medium-wave-sensitive (color blin...dness, deutan) (OPN1MW), mRNA /cds=p(1,1095) /gb=NM_000513 /gi=4503964 /ug=Hs.247787 /len=1095 0.0 100% ...

  4. Unigene BLAST: CBRC-HSAP-23-0071 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-HSAP-23-0071 gnl|UG|Hs#S1730560 Homo sapiens opsin 1 (cone pigments), medium-wave-sensitive (color blin...dness, deutan) (OPN1MW), mRNA /cds=p(1,1095) /gb=NM_000513 /gi=4503964 /ug=Hs.247787 /len=1095 0.0 95% ...

  5. Mapping suitability of rice production systems for mitigation: Strategic approach for prioritizing improved irrigation management across scales

    Science.gov (United States)

    Wassmann, Reiner; Sander, Bjoern Ole

    2016-04-01

    After the successful conclusion of the COP21 in Paris, many developing countries are now embracing the task of reducing emissions with much vigor than previously. In many countries of South and South-East Asia, the agriculture sector constitutes a vast share of the national GHG budget which can mainly be attributed to methane emissions from flooded rice production. Thus, rice growing countries are now looking for tangible and easily accessible information as to how to reduce emissions from rice production in an efficient manner. Given present and future food demand, mitigation options will have to comply with aim of increasing productivity. At the same time, limited financial resources demand for strategic planning of potential mitigation projects based on cost-benefit ratios. At this point, the most promising approach for mitigating methane emissions from rice is an irrigation technique called Alternate Wetting and Drying (AWD). AWD was initially developed for saving water and subsequently, represents an adaptation strategy in its own right by coping with less rainfall. Moreover, AWD also reduces methane emissions in a range from 30-70%. However, AWD is not universally suitable. It is attractive to farmers who have to pump water and may save fuel under AWD, but renders limited incentives in situations where there is no real pressing water scarcity. Thus, planning for AWD adoption at larger scale, e.g. for country-wide programs, should be based on a systematic prioritization of target environments. This presentation encompasses a new methodology for mapping suitability of water-saving in rice production - as a means for planning adaptation and mitigation programs - alongside with preliminary results. The latter comprises three new GIS maps on climate-driven suitability of AWD in major rice growing countries (Philippines, Vietnam, Bangladesh). These maps have been derived from high-resolution data of the areal and temporal extent of rice production that are now

  6. Unigene BLAST: CBRC-HSAP-23-0073 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-HSAP-23-0073 gnl|UG|Hs#S1730883 Homo sapiens opsin 1 (cone pigments), short-wave-sensitive (color blind...ness, tritan) (OPN1SW), mRNA /cds=p(8,1054) /gb=NM_001708 /gi=4502386 /ug=Hs.656404 /len=1101 1e-80 43% ...

  7. Unigene BLAST: CBRC-HSAP-23-0072 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-HSAP-23-0072 gnl|UG|Hs#S1730883 Homo sapiens opsin 1 (cone pigments), short-wave-sensitive (color blind...ness, tritan) (OPN1SW), mRNA /cds=p(8,1054) /gb=NM_001708 /gi=4502386 /ug=Hs.656404 /len=1101 1e-80 43% ...

  8. Structural and Biochemical Characterization of the Oxidoreductase NmDsbA3 from Neisseria meningitidis

    Energy Technology Data Exchange (ETDEWEB)

    Vivian, Julian P.; Scoullar, Jessica; Robertson, Amy L.; Bottomley, Stephen P.; Horne, James; Chin, Yanni; Wielens, Jerome; Thompson, Philip E.; Velkov, Tony; Piek, Susannah; Byres, Emma; Beddoe, Travis; Wilce, Matthew C.J.; Kahler, Charlene M.; Rossjohn, Jamie; Scanlon, Martin J. (UWA); (Monash)

    2009-09-02

    DsbA is an enzyme found in the periplasm of Gram-negative bacteria that catalyzes the formation of disulfide bonds in a diverse array of protein substrates, many of which are involved in bacterial pathogenesis. Although most bacteria possess only a single essential DsbA, Neisseria meningitidis is unusual in that it possesses three DsbAs, although the reason for this additional redundancy is unclear. Two of these N. meningitidis enzymes (NmDsbA1 and NmDsbA2) play an important role in meningococcal attachment to human epithelial cells, whereas NmDsbA3 is considered to have a narrow substrate repertoire. To begin to address the role of DsbAs in the pathogenesis of N. meningitidis, we have determined the structure of NmDsbA3 to 2.3-{angstrom} resolution. Although the sequence identity between NmDsbA3 and other DsbAs is low, the NmDsbA3 structure adopted a DsbA-like fold. Consistent with this finding, we demonstrated that NmDsbA3 acts as a thiol-disulfide oxidoreductase in vitro and is reoxidized by Escherichia coli DsbB (EcDsbB). However, pronounced differences in the structures between DsbA3 and EcDsbA, which are clustered around the active site of the enzyme, suggested a structural basis for the unusual substrate specificity that is observed for NmDsbA3.

  9. Negative-tone imaging with EUV exposure toward 13nm hp

    Science.gov (United States)

    Tsubaki, Hideaki; Nihashi, Wataru; Tsuchihashi, Toru; Yamamoto, Kei; Goto, Takahiro

    2016-03-01

    Negative-tone imaging (NTI) with EUV exposure has major advantages with respect to line-width roughness (LWR) and resolution due in part to polymer swelling and favorable dissolution mechanics. In NTI process, both resist and organic solvents play important roles in determining lithography performances. The present study describes novel chemically amplified resist materials based on NTI technology with EUV using a specific organic solvents. Lithographic performances of NTI process were described in this paper under exposures using ASML NXE:3300 EUV scanner at imec. It is emphasized that 14 nm hp was nicely resolved under exposure dose of 37 mJ/cm2 without any bridge and collapse, which are attributed to the low swelling character of NTI process. Although 13 nm hp resolution was potentially obtained, a pattern collapse still restricts its resolution in case coating resist film thickness is 40 nm. Dark mask limitation due mainly to mask defectivity issue makes NTI with EUV favorable approach for printing block mask to produce logic circuit. A good resolution of CD-X 21 nm/CD-Y 32 nm was obtained for block mask pattern using NTI with usable process window and dose of 49 mJ/cm2. Minimum resolution now reaches CD-X 17 nm / CD-Y 23 nm for the block. A 21 nm block mask resolution was not affected by exposure dose and explored toward low dose down to 18 mJ/cm2 by reducing quencher loading. In addition, there was a negligible amount of increase in LCDU for isolated dot pattern when decreasing exposure dose from 66 mJ/cm2 to 24 mJ/cm2. On the other hand, there appeared tradeoff relationship between LCDU and dose for dense dot pattern, indicating photon-shot noise restriction, but strong dependency on patterning features. Design to improve acid generation efficiency was described based on acid generation mechanism in traditional chemically amplified materials which contains photo-acid generator (PAG) and polymer. Conventional EUV absorber comprises of organic compounds is

  10. Alternate wetting and drying decreases methylmercury in flooded rice (Oryza sativa) systems

    Science.gov (United States)

    Tanner, K. Christy; Windham-Myers, Lisamarie; Marvin-DiPasquale, Mark C.; Fleck, Jacob; Linquist, Bruce A.

    2018-01-01

    In flooded soils, including those found in rice (Oryza sativa L.) fields, microbes convert inorganic Hg to more toxic methylmercury (MeHg). Methylmercury is accumulated in rice grain, potentially affecting health. Methylmercury in rice field surface water can bioaccumulate in wildlife. We evaluated how introducing aerobic periods into an otherwise continuously flooded rice growing season affects MeHg dynamics. Conventional continuously flooded (CF) rice field water management was compared with alternate wetting and drying, where irrigation was stopped twice during the growing season, allowing soil to dry to 35% volumetric moisture content, at which point plots were reflooded (AWD-35). Methylmercury studies began at harvest in Year 3 and throughout Year 4 of a 4-yr replicated field experiment. Bulk soil, water, and plant samples were analyzed for MeHg and total Hg (THg), and iron (Fe) speciation was measured in soil samples. Rice grain yield over 4 yr did not differ between treatments. Soil chemistry responded quickly to AWD-35 dry-downs, showing significant oxidation of Fe(II) accompanied by a significant reduction of MeHg concentration (76% reduction at harvest) compared with CF. Surface water MeHg decreased by 68 and 39% in the growing and fallow seasons, respectively, suggesting that the effects of AWD-35 management can last through to the fallow season. The AWD-35 treatment reduced rice grain MeHg and THg by 60 and 32%, respectively. These results suggest that the more aerobic conditions caused by AWD-35 limited the activity of Hg(II)-methylating microbes and may be an effective way to reduce MeHg concentrations in rice ecosystems.

  11. Power scaling of laser diode pumped Pr3+:LiYF4 cw lasers: efficient laser operation at 522.6 nm, 545.9 nm, 607.2 nm, and 639.5 nm.

    Science.gov (United States)

    Gün, Teoman; Metz, Philip; Huber, Günter

    2011-03-15

    We report efficient cw laser operation of laser diode pumped Pr(3+)-doped LiYF4 crystals in the visible spectral region. Using two InGaN laser diodes emitting at λ(P)=443.9 nm with maximum output power of 1 W each and a 2.9-mm-long crystal with a doping concentration of 0.5%, output powers of 938 mW, 418 mW, 384 mW, and 773 mW were achieved for the laser wavelengths 639.5 nm, 607.2 nm, 545.9 nm, and 522.6 nm, respectively. The maximum absorbed pump powers were approximately 1.5 W, resulting in slope efficiencies of 63.6%, 32.0%, 52.1%, and 61.5%, as well as electro-optical efficiencies of 9.4%, 4.2%, 3.8%, and 7.7%, respectively. Within these experiments, laser diode-pumped laser action at 545.9 nm was demonstrated for what is believed to be the first time.

  12. Immunoreactivities of human nonmetastatic clone 23 and p53 products are disassociated and not good predictors of lymph node metastases in early-stage cervical cancer patients.

    Science.gov (United States)

    Tee, Y T; Wang, P H; Ko, J L; Chen, G D; Chang, H; Lin, L Y

    2007-01-01

    To assess the relation between expressions of human nonmetastatic clone 23 (nm23-H1) and p53 in cervical cancer, their relationships with lymph node metastasis, and further to examine their predictive of lymph node metastases. nm23-H1 and p53 expression profiles were visualized by immunohistochemistry in early-stage cervical cancer specimens. Immunoreactivities of nm23-H1 and p53 were disassociated. The independent variables related with lymph node metastases were grade of cancer cell differentiation (p not good predictors of lymph node metastases in early-stage cervical cancer patients. However, stromal invasion and cell differentiation can predict lymph node metastasis.

  13. High power diode lasers emitting from 639 nm to 690 nm

    Science.gov (United States)

    Bao, L.; Grimshaw, M.; DeVito, M.; Kanskar, M.; Dong, W.; Guan, X.; Zhang, S.; Patterson, J.; Dickerson, P.; Kennedy, K.; Li, S.; Haden, J.; Martinsen, R.

    2014-03-01

    There is increasing market demand for high power reliable red lasers for display and cinema applications. Due to the fundamental material system limit at this wavelength range, red diode lasers have lower efficiency and are more temperature sensitive, compared to 790-980 nm diode lasers. In terms of reliability, red lasers are also more sensitive to catastrophic optical mirror damage (COMD) due to the higher photon energy. Thus developing higher power-reliable red lasers is very challenging. This paper will present nLIGHT's released red products from 639 nm to 690nm, with established high performance and long-term reliability. These single emitter diode lasers can work as stand-alone singleemitter units or efficiently integrate into our compact, passively-cooled Pearl™ fiber-coupled module architectures for higher output power and improved reliability. In order to further improve power and reliability, new chip optimizations have been focused on improving epitaxial design/growth, chip configuration/processing and optical facet passivation. Initial optimization has demonstrated promising results for 639 nm diode lasers to be reliably rated at 1.5 W and 690nm diode lasers to be reliably rated at 4.0 W. Accelerated life-test has started and further design optimization are underway.

  14. Variation of hmF2 and NmF2 deduced from DPS-4 over Multan (Pakistan) and their comparisons with IRI-2012 & IRI-2016 during the deep solar minimum between cycles 23 & 24

    Science.gov (United States)

    Ameen, Muhammad Ayyaz; Khursheed, Haqqa; Jabbar, Mehak Abdul; Ali, Muneeza Salman; Chishtie, Farrukh

    2018-04-01

    We report the results of ionospheric measurements from DPS-4 installed at Multan (Geog coord. 30.18°N, 71.48°E, dip 47.4°). The variations in F2-layer maximum electron density NmF2 and its peak height hmF2 are studied during the deep solar minimum between cycles 23 & 24 i.e 2008-2009 with comparisons conducted with the International Reference Ionosphere (IRI) versions 2012 & 2016. We find that the hmF2 observations peak around the pre-sunrise and sunrise hours depending on the month. Seasonally, the daytime variation of NmF2 is higher in the Equinox and Summer, while daytime hmF2 are slightly higher in the Equinox and Winter. High values of hmF2 around midnight are caused by an increase of upward drifts produced by meridional winds. The ionosphere over Multan, which lies at the verge of low and mid latitude, is affected by both E × B drifts and thermospheric winds as evident from mid-night peaks and near-sunrise dips in hmF2. The results of the comparison of the observed NmF2 and hmF2 for the year 2008-2009 with the IRI-2012 (both NmF2 and hmF2) and IRI-2016 (only hmF2) estimates indicate that for NmF2, IRI-2012 with Consultative Committee International Radio (CCIR) option produces values in better agreement with observed data. Whereas, for hmF2, IRI-2016 with both International Union of Radio Science (URSI) and CCIR SHU-2015 options, predicts well for nighttime hours throughout the year. However, the IRI-2012 with CCIR option produces better agreement with data during daytime hours. Furthermore, IRI-2012 with CCIR option gives better results during Equinox months, whereas, IRI-2016 with both URSI and CCIR SHU-2015 options predict well for Winter and Summer.

  15. Kas kvaliteeti saab odavalt? / tekst ja fotod Kyösti Isosaari ja Vesä Jääskeläinen ; refereeris Ingrid Maasik

    Index Scriptorium Estoniae

    Isosaari, Kyösti

    2008-01-01

    Odavate tööriistade võrdlus. Akutrellid Biltema 17-056, Gern DAN165, Power Craft 66191; elektrilised lööktrellid AWD AWD650, Biltema 17-016, Kraft 500W 13MM; tikksaed Alpha-Tools PS600E, Deuzer M1Q-55T, GeLb M1Q-LB-55; nurklihvmasinad Alpha-Tools WS115, Pro Wor PWS115, Probuilder 44023; taldlihvmasinad Co/Tech 30-8939, Power Craft VM-135, PowerPlus X040

  16. First principles study on the interfacial properties of NM/graphdiyne (NM = Pd, Pt, Rh and Ir): The implications for NM growing

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Zhansheng; Li, Shuo; Lv, Peng [College of Physics and Electronic Engineering, Henan Normal University, Xinxiang 453007 (China); He, Chaozheng, E-mail: hecz2013@nynu.edu.cn [College of Physics and Electronic Engineering, Nanyang Normal University, Nanyang 473061 (China); Ma, Dongwei [School of Physics, Anyang Normal University, Anyang 455000 (China); Yang, Zongxian, E-mail: yzx@henannu.edu.cn [College of Physics and Electronic Engineering, Henan Normal University, Xinxiang 453007 (China); Collaborative Innovation Center of Nano Functional Materials and Applications, Kaifeng (China)

    2016-01-01

    Graphical abstract: - Highlights: • The NM adatoms belong to embedded adsorption in 18C-hexagon of GDY. • The Rh and Ir/GDY can be applied to single metal catalysts or sensors. • A simple linear relationship between E{sub e-ads} and E{sub b} is presented. • The linear relationship can be used in the noble metal modified GDY. - Abstract: Based on the dispersion-corrected density functional calculations (DFT-D), we systematically studied the adsorption of noble metals (NM), Pd, Pt, Rh and Ir, on graphdiyne (GDY). We present a systematic study on the geometry, embedded adsorption energy and electronic structure of four different adatoms adsorbed on the GDY. The strong interaction between the NM adatoms and the GDY substrate is found with the NM embedded in the 18C-hexagon of the GDY. We investigated the mobility of the NM adatoms on the GDY, and found that the mobility barrier energy increases along with the increasing of the embedded adsorption energy. We present the NM adatoms growth of high concentrations on the GDY. Upon the analysis of the electronic structure and the frontier molecular orbitals, Rh and Ir adatoms of low concentrations (about 1.37 at%) on the GDY have the potential to be applied as single metal catalysts or gas molecule sensors.

  17. Comparison of 193 nm and 308 nm laser liquid printing by shadowgraphy imaging

    Energy Technology Data Exchange (ETDEWEB)

    Palla-Papavlu, A., E-mail: apalla@nipne.ro [National Institute for Lasers, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, RO-077125 Bucharest (Romania); Shaw-Stewart, J. [EMPA, Swiss Federal Laboratories for Materials Testing and Research, Laboratory for Functional Polymers, Überlandstrasse 129, 8600 Dübendorf (Switzerland); Paul Scherrer Institute, General Energy Research Department, 5232 Villigen PSI (Switzerland); Mattle, T. [Paul Scherrer Institute, General Energy Research Department, 5232 Villigen PSI (Switzerland); Dinca, V. [National Institute for Lasers, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, RO-077125 Bucharest (Romania); Lippert, T.; Wokaun, A. [Paul Scherrer Institute, General Energy Research Department, 5232 Villigen PSI (Switzerland); Dinescu, M. [National Institute for Lasers, Plasma and Radiation Physics, P.O. Box MG-36, Magurele, RO-077125 Bucharest (Romania)

    2013-08-01

    Over the last years laser-induced forward transfer has emerged as a versatile and powerful tool for engineering surfaces with active compounds. Soft, easily damageable materials can be transferred using a triazene polymer as a sacrificial layer which acts as a pressure generator and at the same time protects the material from direct laser irradiation. To understand and optimize the transfer process of biomolecules in liquid solution by using an intermediate triazene polymer photosensitive layer, shadowgraphy imaging is carried out. Two laser systems i.e. an ArF laser operating at 193 nm and a XeCl laser operating at 308 nm are applied for the transfer. Solutions with 50% v/v glycerol concentration are prepared and the influence of the triazene polymer sacrificial layer thickness (60 nm) on the deposits is studied. The shadowgraphy images reveal a pronounced difference between laser-induced forward transfer using 193 nm or 308 nm, i.e. very different shapes of the ejected liquid.

  18. Compact corner-pumped Nd:YAG/YAG composite slab 1319 nm/1338 nm laser

    International Nuclear Information System (INIS)

    Liu, H; Gong, M; Wushouer, X; Gao, S

    2010-01-01

    A corner-pumped type is a new pumping type in the diode-pumped solid-state lasers, which has the advantages of high pump efficiency and favorable pump uniformity. A corner-pumped Nd:YAG/YAG composite slab continuous-wave 1319 nm/1338 nm dual-wavelength laser is first demonstrated in this paper. When the cavity length is 25 mm, the maximal output power is up to 7.62 W with a slope efficiency of 16.6% and an optical-to-optical conversion efficiency of 17%. The corresponding spectral line widths of 1319 nm laser and 1338 nm laser are 0.11 and 0.1 nm, respectively. The short-term instability of the output power is better than 1% when the pumping power is 39.5 W. The experimental results show that a corner-pumped type is a kind of feasible schedules in the design of diode-pumped solid-state 1.3 μm lasers with low or medium output powers

  19. Picosecond laser texturization of mc-silicon for photovoltaics: A comparison between 1064 nm, 532 nm and 355 nm radiation wavelengths

    Energy Technology Data Exchange (ETDEWEB)

    Binetti, Simona [Department of Materials Science and Milano-Bicocca Solar Energy Research Center (MIB-SOLAR), University of Milano-Bicocca, Via Cozzi 55, 20125 Milano (Italy); Le Donne, Alessia, E-mail: alessia.ledonne@mater.unimib.it [Department of Materials Science and Milano-Bicocca Solar Energy Research Center (MIB-SOLAR), University of Milano-Bicocca, Via Cozzi 55, 20125 Milano (Italy); Rolfi, Andrea [Department of Materials Science and Milano-Bicocca Solar Energy Research Center (MIB-SOLAR), University of Milano-Bicocca, Via Cozzi 55, 20125 Milano (Italy); Jäggi, Beat; Neuenschwander, Beat [Bern University of Applied Sciences, Engineering and Information Technology, Institute for Applied Laser, Photonics and Surface Technologies ALPS, Pestalozzistrasse 20, CH-3400 Burgdorf (Switzerland); Busto, Chiara [ENI Spa, Via Giacomo Fauser, 4, 28100 Novara (Italy); Frigeri, Cesare [CNR-IMEM Institute, Parco Area Delle Scienze 37/A, Fontanini, 43010 Parma (Italy); Scorticati, Davide; Longoni, Luca; Pellegrino, Sergio [Laserpoint Srl, Via Della Burrona 51, 20090 Vimodrone, Milano (Italy)

    2016-05-15

    Highlights: • Self-organized surface structures were produced by picosecond laser pulses on mc-Si. • Three laser wavelengths were used which effectively reduce Si reflectivity up to 8%. • The subsurface damage induced by the three lasers was studied in detail. • μ-Raman, PL and TEM proved that UV laser provides the lowest subsurface damage. • UV laser induced damage is located above the depletion region of the p–n junction. - Abstract: Self-organized surface structures were produced by picosecond laser pulses on multi-crystalline silicon for photovoltaic applications. Three different laser wavelengths were employed (i.e. 1064 nm, 532 nm and 355 nm) and the resulting morphologies were observed to effectively reduce the reflectivity of the samples after laser irradiation. Besides, a comparative study of the laser induced subsurface damage generated by the three different wavelengths was performed by confocal micro-Raman, photoluminescence and transmission electron microscopy. The results of both the structural and optical characterization showed that the mc-Si texturing performed with the laser at 355 nm provides surface reflectivity between 11% and 8% over the spectral range from 400 nm to 1 μm, while inducing the lowest subsurface damage, located above the depletion region of the p–n junction.

  20. A novel photoelectrochemical immunosensor by integration of nanobody and ZnO nanorods for sensitive detection of nucleoside diphosphatase kinase-A

    International Nuclear Information System (INIS)

    Liu, Anran; Yin, Kaifei; Mi, Li; Ma, Mengyao; Liu, Yuanjian; Li, Ying; Wei, Wei; Zhang, Yuanjian; Liu, Songqin

    2017-01-01

    Nucleoside diphosphatase kinase A (NDPK-A) is a metastasis-suppressor protein and a biomarker that act on a wide range cancer cells to inhibit the potential metastasis. Herein, we present a simple photoelectrochemical immunosensor based on ZnO nanorod arrays for the sensitive detection of NDPK-A. The ZnO nanorod arrays cosensitized with CdS nanoparticles and Mn 2+ displayed a high and stable photocurrent response under irradiation. After anti-NPDK-A nanobodies were immobilized to the ZnO nanorod arrays, the proposed immunosensor can be utilized for detecting NPDK-A by monitoring the changes in the photocurrent signals of the electrode resulting from immunoreaction. Accordingly, the well-designed immunosensor exhibited a low limit of detection (LOD) of 0.3 pg mL −1 and a wide linear range from 0.5 pg mL −1 to 10 μg mL −1 . The R 2 of the regression curve is 0.99782. Meanwhile, the good stability, reproducibility and specificity of the resulting photoelectrochemical biosensor are demonstrated. In addition, the presented work would offer a novel and simple approach for the detection of immunoreactions and provide new insights in popularizing the diagnosis of NPDK-A. - Highlights: • A photoelectrochemical immunosensor based on ZnO NAs and NBs was fabricated. • Cosensitized structure of ZnO NAs, CdS and Mn improved the photocurrent response. • An excellent sensitivity and selectivity of NDPK-A detection was obtained.

  1. Passively mode-locked Nd:YVO4 laser operating at 1073 nm and 1085 nm

    Science.gov (United States)

    Waritanant, Tanant; Major, Arkady

    2018-02-01

    A passively mode-locked Nd:YVO4 laser operating at 1073 nm and 1085 nm was demonstrated with an intracavity birefringent filter as the wavelength selecting element. The average output powers achieved were 2.17 W and 2.18 W with optical-to-optical efficiency of 19.6% and 19.7%, respectively. The slope efficiencies were more than 31% at both output wavelengths. The pulse durations at the highest average output power were 10.3 ps and 8.4 ps, respectively. We believe that this is the first report of mode locking of a Nd:YVO4 laser operating at 1073 nm or 1085 nm lines.

  2. CALIPSO lidar calibration at 532 nm: version 4 nighttime algorithm

    Science.gov (United States)

    Kar, Jayanta; Vaughan, Mark A.; Lee, Kam-Pui; Tackett, Jason L.; Avery, Melody A.; Garnier, Anne; Getzewich, Brian J.; Hunt, William H.; Josset, Damien; Liu, Zhaoyan; Lucker, Patricia L.; Magill, Brian; Omar, Ali H.; Pelon, Jacques; Rogers, Raymond R.; Toth, Travis D.; Trepte, Charles R.; Vernier, Jean-Paul; Winker, David M.; Young, Stuart A.

    2018-03-01

    Data products from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) on board Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) were recently updated following the implementation of new (version 4) calibration algorithms for all of the Level 1 attenuated backscatter measurements. In this work we present the motivation for and the implementation of the version 4 nighttime 532 nm parallel channel calibration. The nighttime 532 nm calibration is the most fundamental calibration of CALIOP data, since all of CALIOP's other radiometric calibration procedures - i.e., the 532 nm daytime calibration and the 1064 nm calibrations during both nighttime and daytime - depend either directly or indirectly on the 532 nm nighttime calibration. The accuracy of the 532 nm nighttime calibration has been significantly improved by raising the molecular normalization altitude from 30-34 km to the upper possible signal acquisition range of 36-39 km to substantially reduce stratospheric aerosol contamination. Due to the greatly reduced molecular number density and consequently reduced signal-to-noise ratio (SNR) at these higher altitudes, the signal is now averaged over a larger number of samples using data from multiple adjacent granules. Additionally, an enhanced strategy for filtering the radiation-induced noise from high-energy particles was adopted. Further, the meteorological model used in the earlier versions has been replaced by the improved Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2), model. An aerosol scattering ratio of 1.01 ± 0.01 is now explicitly used for the calibration altitude. These modifications lead to globally revised calibration coefficients which are, on average, 2-3 % lower than in previous data releases. Further, the new calibration procedure is shown to eliminate biases at high altitudes that were present in earlier versions and consequently leads to an improved representation of

  3. Design of Polymer Wavelength Splitter 1310 nm/1550 nm Based on Multimode Interferences

    Directory of Open Access Journals (Sweden)

    V. Prajzler

    2010-12-01

    Full Text Available We report about design of 1x2 1310/1550 nm optical wavelength division multiplexer based on polymer waveguides. The polymer splitter was designed by using RSoft software based on beam propagation method. Epoxy novolak resin polymer was used as core waveguides layer, silicon substrate with silica layer was used as buffer layer and polymethylmethacrylate was used as protection cover layer. The simulation shows that the output energy for the fundamental mode is 67.1 % for 1310 nm and 67.8 % for 1550 nm wavelength.

  4. Depth distribution of abiotic drivers of N mineralization and methane emission from a continuously and intermittently flooded Bangladeshi paddy soil

    Science.gov (United States)

    Akter, Masuda; Kader, Md. Abdul; Pierreux, Sofie; Boeckx, Pascal; Kamal, Ahammad Mostafa; Sleutel, Steven

    2016-04-01

    Water-saving irrigation such as AWD may significantly alter depth profiles of moisture content, pH, Eh and soil microbial activity. Modelling the effect of irrigation management on soil N mineralization, therefore requires detailed insight into depth distribution of these variables and dissolved organic carbon (DOC), and evolution of electron acceptors. We set up a field experiment at Bangladesh Agricultural University from January to May' 2015. The cultivated rice variety (BRRI dhan28) was grown under continuous flooding (CF) and alternate wetting and drying (AWD) management, with 120 kg N ha-1(N120) or without (N0)N fertilizer application. We measured soil mineral N and plant N uptake to evaluate N mineralization. CH4 emissions were monitored with timely gas sample collection and GC-analysis. Soil Eh at four depths and temperature at two depths were monitored continuously by Eh/T°-probes connected to a HYPNOS III data logger (MVH, The Netherlands). Simultaneously, soil solution from three depths were sampled with rhizon samplers to track DOC, Fe and Mn in solution. Over the growing season soil and air temperature increased by 8°C, and soil pH stayed near neutral (6.7 to 7.8). In all depths of AWD and CF, Eh dropped sharply to methanic conditions within 21 days after transplanting (DAT). Low redox-potential continued until 77DAT in all cases, except in the puddle layers under AWD, where redox raised to -200mV during drainage. Fe and Mn in soil solution increased gradually over the growing season, indicating continued reductive dissolution of Fe and Mn (hydro-)oxides. DOC increased continuously as well in all depths. Besides to release of DOC bound to pedogenic oxides upon their reductive dissolution, higher plant and soil microbial activity with increasing soil temperature (till 28°C) through the growing season explains the increasing DOC levels. Increasing methanogenic activity as indicated by the high CH4 emissions at 70-84DAT under both CF and AWD is

  5. Repair of near-UV (365nm or 313 nm) induced DNA strand breaks

    International Nuclear Information System (INIS)

    Miguel, A.G.

    1981-01-01

    The action of near-UV (365 nm or 313 nm) radiation in cellular inactivaton (biological measurements) and induction and repair of breaks (physical measurements) is studied in repair proficient strain and in pol A, rec A and uvr A deficient strains of Escherichia coli K-12. (M.A.C.) [pt

  6. 355-nm hypersensitization of optical fibers

    NARCIS (Netherlands)

    Canagasabey, A.; Canning, J.; Groothoff, N.

    2003-01-01

    A study is presented on 355-nm hypersensitization of optical fibers. It is found that the intrinsic 244-nm photosensitivity of boron-codoped germanosilicate optical fibers is enhanced by 355-nm hypersensitization. Hypersensitization through standard polymer coating is also demonstrated.

  7. A novel photoelectrochemical immunosensor by integration of nanobody and ZnO nanorods for sensitive detection of nucleoside diphosphatase kinase-A

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Anran, E-mail: liuar@seu.edu.cn; Yin, Kaifei; Mi, Li; Ma, Mengyao; Liu, Yuanjian; Li, Ying; Wei, Wei; Zhang, Yuanjian; Liu, Songqin

    2017-06-22

    Nucleoside diphosphatase kinase A (NDPK-A) is a metastasis-suppressor protein and a biomarker that act on a wide range cancer cells to inhibit the potential metastasis. Herein, we present a simple photoelectrochemical immunosensor based on ZnO nanorod arrays for the sensitive detection of NDPK-A. The ZnO nanorod arrays cosensitized with CdS nanoparticles and Mn{sup 2+} displayed a high and stable photocurrent response under irradiation. After anti-NPDK-A nanobodies were immobilized to the ZnO nanorod arrays, the proposed immunosensor can be utilized for detecting NPDK-A by monitoring the changes in the photocurrent signals of the electrode resulting from immunoreaction. Accordingly, the well-designed immunosensor exhibited a low limit of detection (LOD) of 0.3 pg mL{sup −1} and a wide linear range from 0.5 pg mL{sup −1} to 10 μg mL{sup −1}. The R{sup 2} of the regression curve is 0.99782. Meanwhile, the good stability, reproducibility and specificity of the resulting photoelectrochemical biosensor are demonstrated. In addition, the presented work would offer a novel and simple approach for the detection of immunoreactions and provide new insights in popularizing the diagnosis of NPDK-A. - Highlights: • A photoelectrochemical immunosensor based on ZnO NAs and NBs was fabricated. • Cosensitized structure of ZnO NAs, CdS and Mn improved the photocurrent response. • An excellent sensitivity and selectivity of NDPK-A detection was obtained.

  8. Histologic evaluation of laser lipolysis: pulsed 1064-nm Nd:YAG laser versus cw 980-nm diode laser.

    Science.gov (United States)

    Mordon, Serge; Eymard-Maurin, Anne Françoise; Wassmer, Benjamin; Ringot, Jean

    2007-01-01

    The use of the laser as an auxiliary tool has refined the traditional technique for lipoplasty. During laser lipolysis, the interaction between the laser and the fat produced direct cellular destruction before the suction, reduced bleeding, and promoted skin tightening. This study sought to perform a comparative histologic evaluation of laser lipolysis with the pulsed 1064-nm Nd:YAG laser versus a continuous 980-nm diode laser. A pulsed 1064-nm Nd:YAG (Smart-Lipo; Deka, Italy) and a CW 980-nm diode laser (Pharaon, Osyris, France) were evaluated at different energy settings for lipolysis on the thighs of a fresh cadaver. The lasers were coupled to a 600-microm optical fiber inserted in a 1-mm diameter cannula. Biopsy specimens were taken on irradiated and non-irradiated areas. Hematoxylin-erythrosin-safran staining and immunostaining (anti-PS100 polyclonal antibody) were performed to identify fat tissue damage. In the absence of laser exposures (control specimens), cavities created by cannulation were seen; adipocytes were round in appearance and not deflated. At low energy settings, tumescent adipocytes were observed. At higher energy settings, cytoplasmic retraction, disruption of membranes, and heat-coagulated collagen fibers were noted; coagulated blood cells were also present. For the highest energy settings, carbonization of fat tissue involving fibers and membranes was clearly seen. For equivalent energy settings, 1064-nm and 980-nm wavelengths gave similar histologic results. Laser lipolysis is a relatively new technique that is still under development. Our histologic findings suggest several positive benefits of the laser, including skin retraction and a reduction in intraoperative bleeding. The interaction of the laser with the tissue is similar at 980 nm and 1064 nm with the same energy settings. Because higher volumes of fat are removed with higher total energy, a high-power 980-nm diode laser could offer an interesting alternative to the 1064-nm Nd

  9. Hypersensitisation using 266nm Laser Light

    DEFF Research Database (Denmark)

    Sørensen, Henrik Rokkjær; Canning, John; Kristensen, Martin

    UV-hypersensitisation using 266nm VW-light on hydrogenated Ge-doped fibre is reported. The optimum fluence to be between 5 to 10 kJ/cm2, coinciding with results obtained using 355nm light, indicating same end-process in both reactions.......UV-hypersensitisation using 266nm VW-light on hydrogenated Ge-doped fibre is reported. The optimum fluence to be between 5 to 10 kJ/cm2, coinciding with results obtained using 355nm light, indicating same end-process in both reactions....

  10. Advances in 750 nm VECSELs (Conference Presentation)

    Science.gov (United States)

    Saarinen, Esa J.; Ranta, Sanna; Lyytikäinen, Jari; Saarela, Antti; Sirbu, Alexei; Iakovlev, Vladimir; Kapon, Eli; Guina, Mircea

    2017-03-01

    Lasers operating in the transmission window of tissue at wavelengths between 700 and 800 nm are needed in numerous medical and biomedical applications, including photodynamic therapy and fluorescence microscopy. However, the performance of diode lasers in this spectral range is limited by the lack of appropriate compound semiconductors. Here, we review our recent research on 750 nm VECSELs. Two approaches to reaching the 750 nm wavelength will be discussed. The first approach relies on intra-cavity frequency doubling a wafer-fused 1500 nm VECSEL. The VECSEL gain chip comprises a GaAs-based DBR and an InP-based gain section, which allows for optical pumping with low-cost commercial diodes at 980 nm. With this scheme we have achieved watt-level output powers and tuning of the laser wavelength over a 40 nm band at around 750 nm. The second approach is direct emission at 750 nm using the AlGaAs/GaAs material system. In this approach visible wavelengths are required for optical pumping. However, the consequent higher costs compared to pumping at 980 nm are mitigated by the more compact laser setup and prospects of doubling the frequency to the ultraviolet range.

  11. Synthesis and Absolute Configuration of Enantiomerically Pure Vitamin K3 2,3-Epoxide

    NARCIS (Netherlands)

    Snatzke, Günther; Wijnberg, Hans; Feringa, Bernard; Marsman, Bea G.; Greydanus, Ben; Pluim, Henk

    1980-01-01

    The 2,3-epoxide of vitamin K3 (menadione, 1) has been prepared in enantiomerically pure form, and the absolute configuration has been deduced from the CD spectrum. The compound with the negative Cotton effect between 340 and 400 nm has the 2R,3S configuration.

  12. Protein preparation, crystallization and preliminary X-ray analysis of Trypanosoma cruzi nucleoside diphosphate kinase 1

    International Nuclear Information System (INIS)

    Gómez Barroso, J. A.; Pereira, H.; Miranda, M.; Pereira, C.; Garratt, R. C.; Aguilar, C. F.

    2010-01-01

    T. cruzi TcNDPK1 was overexpressed in Escherichia coli as an N-terminally poly-His-tagged fusion protein and crystallized. The flagellated protozoan parasite Trypanosoma cruzi is the aetiological agent of Chagas disease. Nucleoside diphosphate kinases (NDPKs) are enzymes that are involved in energy management and nucleoside balance in the cell. T. cruzi TcNDPK1, a canonical isoform, was overexpressed in Escherichia coli as an N-terminally poly-His-tagged fusion protein and crystallized. Crystals grew after 72 h in 0.2 M MgCl 2 , 20% PEG 3350. Data were collected to 3.5 Å resolution using synchrotron X-ray radiation at the National Synchrotron Light Laboratory (Campinas, Brazil). The crystals belonged to the trigonal space group P3, with unit-cell parameters a = b = 127.84, c = 275.49 Å. Structure determination is under way and will provide relevant information that may lead to the first step in rational drug design for the treatment of Chagas disease

  13. Theoretical designs of 19.6 nm Ne-like Ge XRL source

    International Nuclear Information System (INIS)

    Zhang Guoping; Zhang Tanxin; Zheng Wudi

    2004-01-01

    19.6 nm Ne-like Ge X-ray laser (XRL) can be used as a source to diagnose Rayleigh-Taylor instability in laser induced plasma. In this paper, systemic optimum designs and theoretical analysis to Ne-like Ge XRL driven by pre-main short pulses were conducted by a series of codes, which had been tested by experiments. Simulation results show that, adopting driven conditions of 2%-3% pre-pulse, 6-8 ns pre-main pulse interval and 40 TW/cm 2 power intensity, a gain area of 19.6 nm laser line beyond 60 μm and gain duration of 90 ps can be obtained. Furthermore, with 16 mm plane target, the gain gets to 11.8/cm, and if 6 mrad/cm curved target is adopted, it reaches to 13.3/cm, and small signal gain-length product of single target is about 21.3, which means that saturated gain can be realized by a single target. With double targets opposite coupling, gain-length product can reach 38.4, deep saturation can be gotten, and XRL source required by demonstration of application is out of question

  14. A comparison of the antibacterial activity of the two methods of photodynamic therapy (using diode laser 810 nm and LED lamp 630 nm) against Enterococcus faecalis in extracted human anterior teeth.

    Science.gov (United States)

    Asnaashari, Mohammad; Mojahedi, Seyed Masoud; Asadi, Zahra; Azari-Marhabi, Saranaz; Maleki, Alireza

    2016-03-01

    Failure of endodontic treatment is usually due to an inadequate disinfection of the root canal system. Enterococcus faecalis has been widely used as a valuable microbiological marker for in-vitro studies because of its ability to colonize in a biofilm like style in root canals, invading dentinal tubules and resistance to some endodontic treatments. The aim of this study was to investigate the antibacterial effects of two methods of photodynamic therapy using a light emitting diode lamp (LED lamp, 630 nm) and a diode laser (810 nm) on E. faecalis biofilms in anterior extracted human teeth. Fifty six single-rooted extracted teeth were used in this study. After routine root canal cleansing, shaping and sterilization, the teeth were incubated with E. faecalis for a period of two weeks. Teeth were then divided into two experimental groups (nu=23) and two control groups (nu=5). Teeth in one experimental group were exposed to a diode laser (810 nm), and in the other group samples were exposed to a LED lamp (630 nm). Intracanal bacterial sampling was done, and bacterial survival rate was then evaluated for each group. The Colony Forming Unit (CFU) in LED group (log10 CFUs=4.88±0.82) was significantly lower than the laser group (log CFUs=5.49±0.71) (p value=0.021). CFUs in positive control group (Log10 CFUs=10.96±0.44) were significantly higher than the treatment group (p˂0.001). No bacterial colony was found in negative control group. The results of this research show that photodynamic therapy could be an effective supplement in root canal disinfection. PDT using LED lamp was more effective than diode laser 810 nm in reducing CFUs of E. faecalis in human teeth. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. A comparative study with a 755 nm picosecond Alexandrite laser with a diffractive lens array and a 532 nm/1064 nm Nd:YAG with a holographic optic.

    Science.gov (United States)

    Tanghetti Md, Emil; Jennings, John

    2018-01-01

    This study was performed to better understand the cutaneous effects of using a fractional picosecond laser at 755 nm with a diffractive lens array and a picosecond Nd:YAG laser at 532 mn and 1064 nm with a holographic optic. We characterized the injuries created by these devices on skin clinically and histologically over 24 hours. With this information we modeled the effects of these devices on a cutaneous target. Eight patients, representing Fitzpatrick skin types I-VI, were treated on their backs with a picosecond Alexandrite laser with a diffractive lens array, as well as a picosecond Nd:YAG laser at 532 nm and 1064 nm with a holographic optic. Photographs were taken 15 minutes and 24 hours after treatments. Punch biopsies were obtained at 24 hours and examined histologically. Treatment with the picosecond Nd:YAG laser at both 532 nm and 1064 nm with the holographic optic revealed erythema and small scatted areas of petechial hemorrhage areas immediately and in many cases at 24 hours after treatment. The 755 nm picosecond Alexandrite laser with diffractive lens array produced erythema immediately after treatment, which largely dissipated 24 hours later. Histologies revealed intra-epidermal vacuoles with all three wavelengths. Fractional picosecond Nd:YAG laser at 532 nm and 1064 nm with the holographic optic showed focal areas of dermal and intra-epidermal hemorrhage with areas of vascular damage in some patients. This study demonstrates that both fractional picosecond devices produce vacuoles in the skin, which are most likely due to areas of laser induced optical breakdown (LIOB). In the patients (skin type II-IV) we observed scatter areas of hemorrhage in the skin, due to vascular damage with the 532 nm and 1064 nm, but not with 755 nm wavelengths. Lasers Surg. Med. 50:37-44, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. Comparative analysis of the effect of the GaAlAs laser irradiation in 780 nm and 660 nm in the hypersensitive dentin; Analise comparativa do efeito da irradiacao do laser de GaAlAs em 780 nm e 660 nm na hipersensibilidade dentinaria

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Sun Chien

    2003-07-01

    This study was to evaluate and compare the effects of the low intensity in laser radiation among GaAlAs 780 nm and GaAlAs 660 nm. The main proposal is to verify if there is any difference of the effects or results in low intensity laser application treatment of hypersensitive dentin, keeping the same parameters, only differing in wavelength. The samples were distributed in two groups. Group A 90 cases, treated with GaAlAs 780 nm and group B irradiated with GaAlAs 660 nm with a total of 76 cases analyzed. The results of application with GaAlAs 660 nm and GaAlAs 780 nm do not differ statistically. Which means using any one of the irradiation gives the same results. However can be noted that the response of reduction of hypersensitivity is faster with the radiation of GaAlAs 780 nm, but the results after three applications is the same for both types of radiation. (author)

  17. Efficient continuous-wave 1112 nm Nd:YAG laser operation under direct diode pumping at 885 nm

    International Nuclear Information System (INIS)

    Gao, J; Dai, X J; Zhang, L; Wu, X D

    2013-01-01

    We report compact diode-end-pumped continuous-wave laser operation at 1112 nm under 885 nm diode-direct pumping for the first time. On the basis of the R 2 →Y 6 transition in a conventional Nd:YAG (yttrium aluminum garnet) single crystal, the maximum output power of 12.5 W is achieved, with an optical to optical efficiency of 46.6% and a slope efficiency of 52.9%. To the best of our knowledge, this represents the highest output at 1112 nm generated by a diode-end-pumped Nd:YAG laser. Furthermore, it is the highest optical to optical efficiency ever reported for 1112 nm Nd:YAG lasers. The short term power stability is ∼0.32% at 12.0 W output. (letter)

  18. Dopamine agonist activity of EMD 23,448

    Energy Technology Data Exchange (ETDEWEB)

    Martin, G E; Pettibone, D J [Merck Sharp and Dohme Research Laboratories, West Point, Pennsylvania (USA). Dept. of Pharmacology

    1985-01-01

    EMD 23,448 was examined in tests of dopaminergic function and was found to be an atypical dopamine (DA) agonist. EMD 23,448 was a weak or inactive DA agonist when examined in tests of normal postsynaptic DA receptor function: production of stereotypy in the rat (ED/sub 50/ greater than sign 5.0 mg/kg.i.p.); production of emesis in beagles (minimum effective dose = 81..mu..g/kg i.v.); and, enhanced locomotor activity of the mouse (no excitation in doses <=50 mg/i.p.). Moreover, EMD 23,448 was relatively weak in competing for (/sup 3/H)-apomorphine binding to rat striatal membranes (Ki, 205 nM). On the other hand, this indolyl-3-butylamine did activate supersensitive postsynaptic DA receptors. Specifically, it elicited contralateral turning in rats with a unilateral 6-hydroxydopamine lesion of the substantia nigra (ED/sub 50/ value = 0.9 mg/kg) and did elicit stereotypy in rats given chronic daily haloperidol treatments. EMD 23,448 also exerted pharmacological effects in tests designed to measure activation of dopamine autoreceptors. It inhibited the ..gamma..-butyrolactone-induced increase in striatal dopa levels (ED/sub 50/ = 1 mg/kg i.p.) and produced a dose-related fall in the locomotor activity of the mouse. The results are discussed and contrasted with data derived for apomorphine and the putatively selective autoreceptor agonist (+-)-3-PPP.

  19. Quasi-three level Nd:YLF fundamental and Raman laser operating under 872-nm and 880-nm direct diode pumping

    Science.gov (United States)

    Wetter, Niklaus U.; Bereczki, Allan; Paes, João. Pedro Fonseca

    2018-02-01

    Nd:YLiF4 is the gain material of choice whenever outstanding beam quality or a birefringent gain material is necessary such as in certain applications for terahertz radiation or dual-frequency mode-locking. However, for high power CW applications the material is hampered by a low thermal fracture threshold. This problem can be mitigated by special 2D pump set-ups or by keeping the quantum defect to a minimum. Direct pumping into the upper laser level of Nd:YLiF4 is usually performed at 880 nm. For quasi-three level laser emission at 908 nm, direct pumping at this wavelength provides a high quantum defect of 0.97, which allows for very high CW pump powers. Although the direct pumping transition to the upper laser state at 872 nm has a slightly smaller quantum defect of 0.96, its pump absorption cross section along the c-axis is 50% higher than at 880 nm, leading to a higher absorption efficiency. In this work we explore, for the first time to our knowledge, 908 nm lasing under 872 nm diode pumping and compare the results with 880 nm pumping for quasicw and cw operation. By inserting a KGW crystal in the cavity, Raman lines at 990 nm and 972 nm were obtained for the first time from a directly pumped 908 nm Nd:YLF fundamental laser for both quasi-cw and cw conditions.

  20. Wavelength dependence on the forensic analysis of glass by nanosecond 266 nm and 1064 nm laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cahoon, Erica M.; Almirall, Jose R.

    2010-05-01

    Laser induced breakdown spectroscopy can be used for the chemical characterization of glass to provide evidence of an association between a fragment found at a crime scene to a source of glass of known origin. Two different laser irradiances, 266 nm and 1064 nm, were used to conduct qualitative and quantitative analysis of glass standards. Single-pulse and double-pulse configurations and lens-to-sample-distance settings were optimized to yield the best laser-glass coupling. Laser energy and acquisition timing delays were also optimized to result in the highest signal-to-noise ratio corresponding to the highest precision and accuracy. The crater morphology was examined and the mass removed was calculated for both the 266 nm and 1064 nm irradiations. The analytical figures of merit suggest that the 266 nm and 1064 nm wavelengths are capable of good performance for the forensic chemical characterization of glass. The results presented here suggest that the 266 nm laser produces a better laser-glass matrix coupling, resulting in a better stoichiometric representation of the glass sample. The 266 nm irradiance is therefore recommended for the forensic analysis and comparison of glass samples.

  1. Wavelength dependence on the forensic analysis of glass by nanosecond 266 nm and 1064 nm laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Cahoon, Erica M.; Almirall, Jose R.

    2010-01-01

    Laser induced breakdown spectroscopy can be used for the chemical characterization of glass to provide evidence of an association between a fragment found at a crime scene to a source of glass of known origin. Two different laser irradiances, 266 nm and 1064 nm, were used to conduct qualitative and quantitative analysis of glass standards. Single-pulse and double-pulse configurations and lens-to-sample-distance settings were optimized to yield the best laser-glass coupling. Laser energy and acquisition timing delays were also optimized to result in the highest signal-to-noise ratio corresponding to the highest precision and accuracy. The crater morphology was examined and the mass removed was calculated for both the 266 nm and 1064 nm irradiations. The analytical figures of merit suggest that the 266 nm and 1064 nm wavelengths are capable of good performance for the forensic chemical characterization of glass. The results presented here suggest that the 266 nm laser produces a better laser-glass matrix coupling, resulting in a better stoichiometric representation of the glass sample. The 266 nm irradiance is therefore recommended for the forensic analysis and comparison of glass samples.

  2. Perhydropolysilazane spin-on dielectrics for inter-layer-dielectric applications of sub-30 nm silicon technology

    International Nuclear Information System (INIS)

    Kim, Sam-Dong; Ko, Pil-Seok; Park, Kyoung-Seok

    2013-01-01

    Various material properties of the perhydropolysilazane spin-on dielectric (PHPS SOD) were examined and analyzed in this study as potential inter-layer dielectrics (ILDs) integrated for Si circuits of 30 nm technology or beyond. The spin-coated PHPS (18.5 wt%) layers converted at 650 °C showed comparable but less perfect thermal conversion to silica than the films converted at 1000 °C, however exhibiting excellent gap filling (15 nm gap opening, aspect ratio (AR) of ∼23) and planarization (degree of planarization (DOP) = ∼73% for 800 nm initial step height, cusp angle = ∼16°) sufficient for the Si integration. PHPS SOD layers cured at 650 °C were integrated ILDs in the 0.18 µm Si front-end-of-the-line process, and the estimated hot-carrier reliability of n-channel metal oxide semiconductor transistors (ten years at a drain voltage of 1.68 V) had no significant difference from that of the transistors integrated with the conventional borophosposilicate glass ILDs. A modified contact pre-cleaning scheme using N 2 O plasma treatment also produced uniform and stable contact chain resistances from the SOD ILDs. (paper)

  3. Solar spectral irradiance variability of some chromospheric emission lines through the solar activity cycles 21-23

    Directory of Open Access Journals (Sweden)

    Göker Ü.D.

    2017-01-01

    Full Text Available A study of variations of solar spectral irradiance (SSI in the wave-length ranges 121.5 nm-300.5 nm for the period 1981-2009 is presented. We used various data for ultraviolet (UV spectral lines and international sunspot number (ISSN from interactive data centers such as SME (NSSDC, UARS (GDAAC, SORCE (LISIRD and SIDC, respectively. We reduced these data by using the MATLsoftware package. In this respect, we revealed negative correlations of intensities of UV (289.5 nm-300.5 nm spectral lines originating in the solar chromosphere with the ISSN index during the unusually prolonged minimum between the solar activity cycles (SACs 23 and 24. We also compared our results with the variations of solar activity indices obtained by the ground-based telescopes. Therefore, we found that plage regions decrease while facular areas are increasing in SAC 23. However, the decrease in plage regions is seen in small sunspot groups (SGs, contrary to this, these regions in large SGs are comparable to previous SACs or even larger as is also seen in facular areas. Nevertheless, negative correlations between ISSN and SSI data indicate that these variations are in close connection with the classes of sunspots/SGs, faculae and plage regions. Finally, we applied the time series analysis of spectral lines corresponding to the wavelengths 121.5 nm-300.5 nm and made comparisons with the ISSN data. We found an unexpected increase in the 298.5 nm line for the Fe II ion. The variability of Fe II ion 298.5 nm line is in close connection with the facular areas and plage regions, and the sizes of these solar surface indices play an important role for the SSI variability, as well. So, we compared the connection between the sizes of faculae and plage regions, sunspots/SGs, chemical elements and SSI variability. Our future work will be the theoretical study of this connection and developing of a corresponding model.

  4. Efficacy of treating children with anterior commissure and true vocal fold respiratory papilloma with the 585-nm pulsed-dye laser.

    Science.gov (United States)

    Hartnick, Christopher J; Boseley, Mark E; Franco, Ramon A; Cunningham, Michael J; Pransky, Seth

    2007-02-01

    To report preliminary results regarding the safety and efficacy of the 585-nm pulsed-dye laser (PDL) for the treatment of juvenile-onset recurrent respiratory papillomatosis (JORRP) in the pediatric population. Prospective longitudinal cohort study. Two pediatric otolaryngology referral centers. Twenty-three pediatric patients ranging in age from 6 months to 17 years. The 585-nm PDL was used for at least 1 treatment on each of these patients to treat JORRP of the true vocal folds or anterior commissure. Complications from the use of the 585-nm PDL in the treatment of JORRP. There was no evidence of anterior commissure webbing or true vocal fold scarring in this group of 23 patients followed up for 3 months to 1 year. The 585-nm PDL seems to be a safe instrument for treatment of JORRP. There is the potential that improved voice outcomes may be apparent when compared with traditional therapies because the vocal fold epithelium seems to be unharmed when treated with this method. Furthermore, the lack of epithelial damage incurred by the 585-nm PDL should enable more aggressive surgical excision of anterior commissure disease. Further prospective longitudinal studies examining voice outcomes are needed.

  5. Characterization of LANDSAT Panels Using the NIST BRDF Scale from 1100 nm to 2500 nm

    Science.gov (United States)

    Markham, Brian; Tsai, Benjamin K.; Allen, David W.; Cooksey, Catherine; Yoon, Howard; Hanssen, Leonard; Zeng, Jinan; Fulton, Linda; Biggar, Stuart; Markham, Brian

    2010-01-01

    Many earth observing sensors depend on white diffuse reflectance standards to derive scales of radiance traceable to the St Despite the large number of Earth observing sensors that operate in the reflective solar region of the spectrum, there has been no direct method to provide NIST traceable BRDF measurements out to 2500 rim. Recent developments in detector technology have allowed the NIST reflectance measurement facility to expand the operating range to cover the 250 nm to 2500 nm range. The facility has been modified with and additional detector using a cooled extended range indium gallium arsenide (Extended InGaAs) detector. Measurements were made for two PTFE white diffuse reflectance standards over the 1100 nm to 2500 nm region at a 0' incident and 45' observation angle. These two panels will be used to support the OLI calibration activities. An independent means of verification was established using a NIST radiance transfer facility based on spectral irradiance, radiance standards and a diffuse reflectance plaque. An analysis on the results and associated uncertainties will be discussed.

  6. Photobiomodulation reduces photoreceptor death and regulates cytoprotection in early states of P23H retinal dystrophy

    Science.gov (United States)

    Kirk, Diana K.; Gopalakrishnan, Sandeep; Schmitt, Heather; Abroe, Betsy; Stoehr, Michele; Dubis, Adam; Carroll, Joseph; Stone, Jonathan; Valter, Krisztina; Eells, Janis

    2013-03-01

    Irradiation by light in the far-red to near-infrared (NIR) region of the spectrum (photobiomodulation, PBM) has been demonstrated to attenuate the severity of neurodegenerative disease in experimental and clinical studies. The purpose of this study was to test the hypothesis that 670 nm PBM would protect against the loss of retinal function and improve photoreceptor survival in a rodent model of retinitis pigmentosa, the P23H transgenic rat. P23H rat pups were treated once per day with a 670 nm LED array (180 sec treatments at 50 mW/cm2; fluence 9 joules/cm2) (Quantum Devices Inc., Barneveld WI) from postnatal day (p) 16-20 or from p10-20. Sham-treated rats were restrained, but not exposed to NIR light. The status of the retina was determined at p22 by assessment of mitochondrial function, oxidative stress and cell death. In a second series of studies, retinal status was assessed at p30 by measuring photoreceptor function by ERG and retinal morphology by Spectral Domain Optical Coherence Tomography (SD-OCT). 670 nm PBM increased retinal mitochondrial cytochrome oxidase activity and upregulated the retina's production of the key mitochondrial antioxidant enzyme, MnSOD. PBM also attenuated photoreceptor cell loss and improved photoreceptor function. PBM protects photoreceptors in the developing P23H retina, by augmenting mitochondrial function and stimulating antioxidant protective pathways. Photobiomodulation may have therapeutic potential, where mitochondrial damage is a step in the death of photoreceptors.

  7. Magnetic Susceptibility of liquid Gd-NM (NM = Cu, Ga, Ge alloys

    Directory of Open Access Journals (Sweden)

    Shimakura Hironori

    2017-01-01

    Full Text Available For rare earth alloys, the indirect interaction of RKKY is at work between rare-earth atoms. Therefore, the magnetism of them depends on the number of conduction electrons and the distance between rare-earth metals. In this work, to reveal the relationship between the number of conduction electrons and magnetic property of rare earth metal alloys, magnetic susceptibility measurements for liquid Gd-NM (NM = Cu, Ga, Ge was performed by Faraday method. As the results, it was observed that the sign of paramagnetic Curie temperature of Cu-Gd alloys are positive at all composition, while Ga-Gd and Ge-Gd alloys show negative paramagnetic Curie temperature at certain composition. Moreover, it was indicated when the alloy at certain composition shows highest melting temperature, it has the lowest paramagnetic Curie temperature.

  8. Laser Application in Dentistry: Irradiation Effects of Nd:YAG 1064 nm and Diode 810 nm and 980 nm in Infected Root Canals—A Literature Overview

    Science.gov (United States)

    Kuypers, Thorsten; Gutknecht, Norbert

    2016-01-01

    Objective. In endodontics, Nd:YAG laser (1064 nm) and diode laser (810 nm and 980 nm) devices are used to remove bacteria in infected teeth. A literature review was elaborated to compare and evaluate the advantages and disadvantages of using these lasers. Methods. Using combined search terms, eligible articles were retrieved from PubMed and printed journals. The initial search yielded 40 titles and 27 articles were assigned to full-text analysis. The studies were classified based upon laser source, laser energy level, duration/similarity of application, and initial and final bacterial count at a minimum of 20 prepared root canals. Part of the analysis was only reduced microorganisms and mechanically treated root canals upon preparation size of ISO 30. All studies were compared to evaluate the most favorable laser device for best results in endodontic therapy. Results. A total of 22 eligible studies were found regarding Nd:YAG laser 1064 nm. Four studies fulfilled all demanded criteria. Seven studies referring to the diode laser 980 nm were examined, although only one fulfilled all criteria. Eleven studies were found regarding the diode laser 810 nm, although only one study fulfilled all necessary criteria. Conclusions. Laser therapy is effective in endodontics, although a comparison of efficiency between the laser devices is not possible at present due to different study designs, materials, and equipment. PMID:27462611

  9. Laser Application in Dentistry: Irradiation Effects of Nd:YAG 1064 nm and Diode 810 nm and 980 nm in Infected Root Canals-A Literature Overview.

    Science.gov (United States)

    Saydjari, Yves; Kuypers, Thorsten; Gutknecht, Norbert

    2016-01-01

    Objective. In endodontics, Nd:YAG laser (1064 nm) and diode laser (810 nm and 980 nm) devices are used to remove bacteria in infected teeth. A literature review was elaborated to compare and evaluate the advantages and disadvantages of using these lasers. Methods. Using combined search terms, eligible articles were retrieved from PubMed and printed journals. The initial search yielded 40 titles and 27 articles were assigned to full-text analysis. The studies were classified based upon laser source, laser energy level, duration/similarity of application, and initial and final bacterial count at a minimum of 20 prepared root canals. Part of the analysis was only reduced microorganisms and mechanically treated root canals upon preparation size of ISO 30. All studies were compared to evaluate the most favorable laser device for best results in endodontic therapy. Results. A total of 22 eligible studies were found regarding Nd:YAG laser 1064 nm. Four studies fulfilled all demanded criteria. Seven studies referring to the diode laser 980 nm were examined, although only one fulfilled all criteria. Eleven studies were found regarding the diode laser 810 nm, although only one study fulfilled all necessary criteria. Conclusions. Laser therapy is effective in endodontics, although a comparison of efficiency between the laser devices is not possible at present due to different study designs, materials, and equipment.

  10. Sub-10 nm structures on silicon by thermal dewetting of platinum

    International Nuclear Information System (INIS)

    Strobel, Sebastian; Kirkendall, Christopher; Chang, Jae-Byum; Berggren, Karl K

    2010-01-01

    A study of the dewetting behavior of platinum-thin-films on silicon was carried out to determine how variation of dewetting parameters affects the evolution of film morphology and to pinpoint which parameters yielded the smallest, most circular features. Platinum film thickness as well as dewetting time and temperature were varied and the film morphology characterized by means of scanning electron microscopy (SEM) analysis. Two different pathways of dewetting predicted in the literature (Vrij 1966 Discuss. Faraday Soc. 42 23, Becker et al 2003 Nat. Mater. 2 59-63) were observed. Depending on the initial criteria, restructuring of the film occurred via hole or droplet formation. With increased annealing time, a transition from an intermediate network structure to separated islands occurred. In addition, the formation of multilayered films, silicide crystals and nanowires occurred for certain parameters. Nevertheless, the dewetting behavior witnessed could be related to physical processes. Droplets with a mean diameter of 9 nm were formed by using a 1.5 nm thick platinum film annealed at 800 deg. C for 30 s. To demonstrate the suitability of the annealed films for further processing, we then used the dewetted films as masks for reactive ion etching to transfer the pattern into the silicon substrate, forming tapered nanopillars.

  11. Dopamine agonist activity of EMD 23,448

    International Nuclear Information System (INIS)

    Martin, G.E.; Pettibone, D.J.

    1985-01-01

    EMD 23,448 was examined in tests of dopaminergic function and was found to be an atypical dopamine (DA) agonist. EMD 23,448 was a weak or inactive DA agonist when examined in tests of normal postsynaptic DA receptor function: production of stereotypy in the rat (ED 50 greater than sign 5.0 mg/kg.i.p.); production of emesis in beagles (minimum effective dose = 81μg/kg i.v.); and, enhanced locomotor activity of the mouse (no excitation in doses 3 H]-apomorphine binding to rat striatal membranes (Ki, 205 nM). On the other hand, this indolyl-3-butylamine did activate supersensitive postsynaptic DA receptors. Specifically, it elicited contralateral turning in rats with a unilateral 6-hydroxydopamine lesion of the substantia nigra (ED 50 value = 0.9 mg/kg) and did elicit stereotypy in rats given chronic daily haloperidol treatments. EMD 23,448 also exerted pharmacological effects in tests designed to measure activation of dopamine autoreceptors. It inhibited the γ-butyrolactone-induced increase in striatal dopa levels (ED 50 = 1 mg/kg i.p.) and produced a dose-related fall in the locomotor activity of the mouse. The results are discussed and contrasted with data derived for apomorphine and the putatively selective autoreceptor agonist (+-)-3-PPP. (Author)

  12. Association of protein C23 with rapidly labeled nucleolar RNA

    International Nuclear Information System (INIS)

    Herrera, A.H.; Olson, M.O.

    1986-01-01

    The association of nucleolar phosphoprotein C23 with preribosomal ribonucleoprotein (RNP) particles was examined in Novikoff hepatoma nucleoli. RNA was labeled with [ 3 H]uridine for various times in cell suspensions, and RNP particles were extracted from isolated nucleoli and fractionated by sucrose gradient ultracentrifugation. The majority of protein C23 cosedimented with fractions containing rapidly labeled RNA (RL fraction). To determine whether there was a direct association of RNA with protein C23, the RL fraction was exposed to ultraviolet (UV) light (254 nm) for short periods of time. After 2 min of exposure there was a 50% decrease in C23 as measured by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) analyses, with no significant further decrease at longer times. When UV-treated fractions were subjected to phenol/chloroform extractions, as much as 30% of the labeled RNA was found in the phenol (protein) layer, indicating that RNA became cross-linked to protein. Similarly, there was an increase in protein C23 extracted into the water layer after irradiation. By SDS-PAGE analyses the cross-linked species migrated more slowly than protein C23, appearing as a smear detected either by [ 3 H]uridine radioactivity or by anti-C23 antibody. With anti-C23 antibodies, up to 25% of the labeled RNA was precipitated from the RL fraction. Dot-blot hybridizations, using cloned rDNA fragments as probes, indicated that the RNA in the RL fraction and the immunoprecipitated RNA contained sequences from 18S and 28S ribosomal RNA

  13. Inhibition of nucleoside diphosphate kinase activity by in vitro phosphorylation by protein kinase CK2. Differential phosphorylation of NDP kinases in HeLa cells in culture

    DEFF Research Database (Denmark)

    Biondi, R M; Engel, M; Sauane, M

    1996-01-01

    that in vitro protein kinase CK2 catalyzed phosphorylation of human NDPK A inhibits its enzymatic activity by inhibiting the first step of its ping-pong mechanism of catalysis: its autophosphorylation. Upon in vivo 32P labeling of HeLa cells, we observed that both human NDPKs, A and B, were autophosphorylated...

  14. Macular autofluorescence in eyes with cystoid macula edema, detected with 488 nm-excitation but not with 580 nm-excitation.

    Science.gov (United States)

    Bessho, Kenichiro; Gomi, Fumi; Harino, Seiyo; Sawa, Miki; Sayanagi, Kaori; Tsujikawa, Motokazu; Tano, Yasuo

    2009-06-01

    Fundus autofluorescence (AF) derives from lipofuscin in the retinal pigment epithelium (RPE). Because lipofuscin is a by-product of phagocytosis of photoreceptors by RPE, AF imaging is expected to describe some functional aspect of the retina. In this study we report distribution of AF in patients showing macular edema. Three eyes with diabetic macular edema (DME) and 11 with retinal vein occlusion (RVO), associated with macular edema (ME) were examined. ME was determined by standard fundus examination, fluorescein angiography (FA) and optical coherence tomography (OCT). AF was recorded using a Heidelberg confocal scanning laser ophthalmoscope (cSLO) with 488 nm laser exciter (488 nm-AF), and a conventional Topcon fundus camera with halogen lamp exciter and 580 nm band-pass filter (580 nm-AF). Color fundus picture, FA image and these two AF images were analyzed by superimposing all images. All subjects presented cystoid macular edema (CME) with petaloid pattern hyperfluorescence in FA. In 488 nm-AF, all eyes (100%) showed macular autofluorescence of a similar shape to that of the CME in FA. In contrast, in 580 nm-AF only one eye (7%) presented this corresponding petaloid-shaped autofluorescence. In all cases, peripheral retinal edemas did not show autofluorescence corresponding to the leakage in FA. In eyes with CME, analogous hyperautofluorescence to the CME was always observed in 488 nm-AF, while it was rarely observed in 580 nm-AF. Moreover, this CME hyperautofluorescence was only seen in the macular area. We hypothesize that autofluorescence from CME may be considered as a "pseudo" or "relative" autofluorescence, due to macular stretching following CME that may result in lateral displacement of macular pigments (MPs) and subsequent reduction of MPs density, as MPs block 488 nm-AF more intensely than 580 nm-AF. Although this phenomenon may not directly indicate change of RPE function, it may be used as a method to assess or track CME non-invasively.

  15. Monolithic PM Raman fiber laser at 1679 nm for Raman amplification at 1810 nm

    DEFF Research Database (Denmark)

    Svane, Ask Sebastian; Rottwitt, Karsten

    2013-01-01

    Stimulated Raman scattering (SRS) has been subject to much attention within the field of fiber lasers and amplifiers as it provides an extended wavelength coverage in comparison to rare-earth based devices. Motivated by the projected capacity crunch [1], different approaches are being explored...... demonstrate a monolithic RM Raman fiber laser (RFL), which acts as a pump for a Raman amplifier (RA) at 1810 nm. The lasing wavelength of a RFL, thus also for a RA, can in principle be designed arbitrarily within the entire wavelength range from the Erbium band up to the Thulium/Holmium band...... of OFS PM Raman fiber, with an estimated propagation loss of 0.42/0.46/1.3 dB/km at 1564/1679/1810 nm. The Raman gain coefficient was measured to be gR=2.66/2.35 W-1km-1 at 1679/1810 nm. The laser curve of the RFL is depicted in Fig. 1b, with a slope efficiency of 67 %. The high slope efficiency...

  16. 308nm Excimer Laser in Dermatology

    Science.gov (United States)

    Mehraban, Shadi

    2014-01-01

    308nm xenon-chloride excimer laser, a novel mode of phototherapy, is an ultraviolet B radiation system consisting of a noble gas and halide. The aim of this systematic review was to investigate the literature and summarize all the experiments, clinical trials and case reports on 308-nm excimer laser in dermatological disorders. 308-nm excimer laser has currently a verified efficacy in treating skin conditions such as vitiligo, psoriasis, atopic dermatitis, alopecia areata, allergic rhinitis, folliculitis, granuloma annulare, lichen planus, mycosis fungoides, palmoplantar pustulosis, pityriasis alba, CD30+ lympho proliferative disorder, leukoderma, prurigo nodularis, localized scleroderma and genital lichen sclerosus. Although the 308-nm excimer laser appears to act as a promising treatment modality in dermatology, further large-scale studies should be undertaken in order to fully affirm its safety profile considering the potential risk, however minimal, of malignancy, it may impose. PMID:25606333

  17. Cryogenic Lifetime Studies of 130 nm and 65 nm CMOS Technologies for High-Energy Physics Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Hoff, James R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Deptuch, G. W. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Wu, Guoying [Southern Methodist Univ., Dallas, TX (United States); Gui, Ping [Southern Methodist Univ., Dallas, TX (United States)

    2015-06-04

    The Long Baseline Neutrino Facility intends to use unprecedented volumes of liquid argon to fill a time projection chamber in an underground facility. Research is under way to place the electronics inside the cryostat. For reasons of efficiency and economics, the lifetimes of these circuits must be well in excess of 20 years. The principle mechanism for lifetime degradation of MOSFET devices and circuits operating at cryogenic temperatures is hot carrier degradation. Choosing a process technology that is, as much as possible, immune to such degradation and developing design techniques to avoid exposure to such damage are the goals. This, then, requires careful investigation and a basic understanding of the mechanisms that underlie hot carrier degradation and the secondary effects they cause in circuits. In this work, commercially available 130 nm and 65 nm nMOS transistors operating at cryogenic temperatures are investigated. Our results show that both technologies achieve the lifetimes required by the experiment. Minimal design changes are necessary in the case of the 130 nm process and no changes whatsoever are necessary for the 65 nm process.

  18. MED23-associated intellectual disability in a non-consanguineous family.

    Science.gov (United States)

    Trehan, Aditi; Brady, Jacqueline M; Maduro, Valerie; Bone, William P; Huang, Yan; Golas, Gretchen A; Kane, Megan S; Lee, Paul R; Thurm, Audrey; Gropman, Andrea L; Paul, Scott M; Vezina, Gilbert; Markello, Thomas C; Gahl, William A; Boerkoel, Cornelius F; Tifft, Cynthia J

    2015-06-01

    Intellectual disability (ID) is a heterogeneous condition arising from a variety of environmental and genetic factors. Among these causes are defects in transcriptional regulators. Herein, we report on two brothers in a nonconsanguineous family with novel compound heterozygous, disease-segregating mutations (NM_015979.3: [3656A > G];[4006C > T], NP_057063.2: [H1219R];[R1336X]) in MED23. This gene encodes a subunit of the Mediator complex that modulates the expression of RNA polymerase II-dependent genes. These brothers, who had profound ID, spasticity, congenital heart disease, brain abnormalities, and atypical electroencephalography, represent the first case of MED23-associated ID in a non-consanguineous family. They also expand upon the clinical features previously reported for mutations in this gene. © 2015 Wiley Periodicals, Inc.

  19. Adsorption of the diazo dye Direct Red 23 onto a zinc oxide surface: A spectroscopic study

    Science.gov (United States)

    Lucilha, Adriana Campano; Bonancêa, Carlos Eduardo; Barreto, Wagner José; Takashima, Keiko

    2010-01-01

    The adsorption of the diazo dye Direct Red 23 onto a zinc oxide surface at 30 °C in the dark was investigated. The color reduction was monitored by spectrophotometry at 503 nm. The FTIR and Raman spectra of the Direct Red 23 adsorption as a function of ZnO concentration were registered. From the PM3 semi-empirical calculations of the atomic charge density and dipole moment of the Direct Red 23 molecule, it was demonstrated that the azo dye molecule may be adsorbed onto the ZnO surface through molecule geometry modifications, enhancing the interfacial area causing a variation in the bonding frequencies.

  20. Capillary Condensation in 8 nm Deep Channels.

    Science.gov (United States)

    Zhong, Junjie; Riordon, Jason; Zandavi, Seyed Hadi; Xu, Yi; Persad, Aaron H; Mostowfi, Farshid; Sinton, David

    2018-02-01

    Condensation on the nanoscale is essential to understand many natural and synthetic systems relevant to water, air, and energy. Despite its importance, the underlying physics of condensation initiation and propagation remain largely unknown at sub-10 nm, mainly due to the challenges of controlling and probing such small systems. Here we study the condensation of n-propane down to 8 nm confinement in a nanofluidic system, distinct from previous studies at ∼100 nm. The condensation initiates significantly earlier in the 8 nm channels, and it initiates from the entrance, in contrast to channels just 10 times larger. The condensate propagation is observed to be governed by two liquid-vapor interfaces with an interplay between film and bridging effects. We model the experimental results using classical theories and find good agreement, demonstrating that this 8 nm nonpolar fluid system can be treated as a continuum from a thermodynamic perspective, despite having only 10-20 molecular layers.

  1. Comparison of the ablation ability of nucleus pulposus after 1,064 nm Nd:YAG laser and 980 nm diode laser radiation.

    Science.gov (United States)

    Yin, Jian; Han, Zhengfeng; Guo, Baofeng; Guo, Han; Zhang, Tongtong; Zeng, Yanjun; Ren, Longxi

    2015-07-01

    To compare the ablation ability of nucleus pulposus after 1,064 nm Nd:YAG laser and 980 nm diode laser radiation. Goat spine specimen (GSS) was radiated using Nd:YAG laser and 980 nm diode laser and then divided into five groups based on the final energy--200, 400, 600, 800 and 1,000 J groups. The ablation quality of nucleus pulposus after radiation was recorded. The ablation quality of GSS was greater at higher radiation energies in both lasers. When compared at the same energy level, the ablation quality of GSS was greater in 980 nm diode laser than in 1,064 nm Nd:YAG laser. Statistical significance was observed in 200 and 400 J groups (P diode laser showed better ablation ability than 1,064 nm Nd:YAG laser.

  2. PILOT STUDY: Report on the CCPR Pilot Comparison: Spectral Responsivity 10 nm to 20 nm

    Science.gov (United States)

    Scholze, Frank; Vest, Robert; Saito, Terubumi

    2010-01-01

    The CCPR Pilot Comparison on spectral responsivity in the 10 nm to 20 nm spectral range was carried out within the framework of the CIPM Mutual Recognition Arrangement by three laboratories: PTB (Germany), NIST (USA), and NMIJ/AIST (Japan) with PTB acting as the central and reporting laboratory. All participating laboratories used monochromatized synchrotron radiation. PTB and NIST used a cryogenic radiometer as the primary standard detector and NMIJ, an ionization chamber with extrapolation by a wavelength-independent detector. The aim of the pilot comparison was to check the accuracy of the radiometric scale of spectral responsivity in the short wavelength EUV spectral range which has recently gained in technological importance. The wavelengths of measurement were from 11.5 nm to 20 nm in 0.5 nm steps and additionally 12.2 nm. The comparison was carried out through the calibration of a group of transfer standard detectors. Two sets of three diodes of types AXUV and SXUV from International Radiation Detectors, Inc. were used for the comparison. The comparison had the form of a star comparison: Pilot-lab A-pilot-lab B-pilot, PTB acting as the pilot laboratory. All results were communicated directly to the pilot laboratory. The report describes in detail the measurements made at PTB and summarizes the reports submitted by the participants. Measurements carried out by the pilot laboratory before and after the circulation of the detectors proved that the stability of the detectors was sufficient for the comparison. For the type AXUV detectors, however, changes in their responsivity contributed to the uncertainty of the comparison. Measurement results from participants and their associated uncertainties were analyzed in this report according to the Guidelines for CCPR Comparison Report Preparation. The uncertainty contributions were separated, as to whether they are wavelength dependent or not. All bilateral DoE are well within the respective k = 2 expanded uncertainty

  3. Improvement of walking distance by defibrotide in patients with intermittent claudication--results of a randomized, placebo-controlled study (the DICLIS study). Defibrotide Intermittent CLaudication Italian Study.

    Science.gov (United States)

    Violi, F; Marubini, E; Coccheri, S; Nenci, G G

    2000-05-01

    Defibrotide is an antithrombotic drug which enhances prostacyclin production and activates fibrinolytic system. The aim of this study was to investigate the improvement of walking distance in patients with intermittent claudication treated with defibrotide. DICLIS was a double blind, placebo-controlled study which included patients with walking distance autonomy at a standardized treadmill test or =100 meters. A total of 310 patients were randomly allocated to placebo (n = 101), defibrotide 800 mg/day (n = 104) or defibrotide 1200 mg/day (n = 105). During a one year follow-up, the Absolute Walking Distance (AWD) was measured six times (0, 30, 60, 90, 180, 360 days). Similar improvement in walking distance was found in the three groups until the 90th day; thereafter placebo group showed no further increase, while AWD continued to increase in the defibrotide groups. Between the 180th and 360th day visits, AWD was significantly higher (P defibrotide than in patients given placebo. No difference in efficacy was observed between the two dosages of defibrotide. No differences in side effects were observed among the three groups. The results of the present trial suggest that long-term administration of defibrotide improves walking distance in patients with intermittent claudication.

  4. 5.5nm wavelength-tunable high-power MOPA diode laser system at 971 nm

    Science.gov (United States)

    Tawfieq, Mahmoud; Müller, André; Fricke, Jörg; Della Casa, Pietro; Ressel, Peter; Ginolas, Arnim; Feise, David; Sumpf, Bernd; Tränkle, Günther

    2018-02-01

    In this work, a widely tunable hybrid master oscillator power amplifier (MOPA) diode laser with 6.2 W of output power at 971.8 nm will be presented. The MO is a DBR laser, with a micro heater embedded on top of the DBR grating for wavelength tunability. The emitted light of the MO is collimated and coupled into a tapered amplifier using micro cylindrical lenses, all constructed on a compact 25 mm × 25 mm conduction cooled laser package. The MOPA system emits light with a measured spectral width smaller than 17 pm, limited by the spectrometer, and with a beam propagation factor of M2 1/e2 = 1.3 in the slow axis. The emission is thus nearly diffraction limited with 79% of the total power within the central lobe (4.9 W diffraction limited). The electrically controlled micro-heater provides up to 5.5 nm of wavelength tunability, up to a wavelength of 977.3 nm, while maintaining an output power variation of only +/- 0.16 % for the entire tuning range.

  5. MED23-associated Intellectual Disability in a Non-consanguineous Family

    OpenAIRE

    Trehan, Aditi; Brady, Jacqueline M.; Maduro, Valerie; Bone, William; Huang, Yan; Golas, Gretchen A.; Kane, Megan; Lee, Paul R.; Thurm, Audrey; Gropman, Andrea L.; Paul, Scott M.; Vezina, Gilbert; Markello, Thomas C.; Gahl, William A.; Boerkoel, Cornelius F.

    2015-01-01

    Intellectual disability (ID) is a heterogeneous condition arising from a variety of environmental and genetic factors. Among these causes are defects in transcriptional regulators. Herein, we report two brothers in a non-consanguineous family with novel compound heterozygous, disease-segregating mutations (NM_015979.3: [3656A>G];[4006C>T], NP_057063.2: [H1219R];[R1336X]) in MED23. This gene encodes a subunit of the Mediator complex that modulates the expression of RNA polymerase II-dependent ...

  6. Laser hypersensitisation using 266nm light

    DEFF Research Database (Denmark)

    Sørensen, Henrik Rokkjær; Canning, J.; Kristensen, Martin

    2005-01-01

    UV hypersensitisation using CW 266 nm light on hydrogenated Ge-doped fibre is reported. The optimum sensitisation fluence is found to be in the range of 5 to 10 kJ/cm2, coinciding with previous results obtained using 355 nm light, indicating the same end-process used in the photochemical reaction...

  7. Laser Shock Processing of 6061-T6 Al alloy with 1064 nm and 532 nm wavelengths

    International Nuclear Information System (INIS)

    Gomez-Rosas, G.; Rubio-Gonzalez, C.; Ocana, J.L.; Molpeceres, C.; Porro, J.A.; Morales, M.; Casillas, F.J.

    2010-01-01

    Laser Shock Processing (LSP) has been proposed as a competitive alternative technology to classical treatments for improving fatigue and wear resistance of metals. We present a configuration and results in the LSP concept for metal surface treatments in underwater laser irradiation at 532 nm and 1064 nm. The purpose of the work is to compare the effect of both wavelengths on the same material. A convergent lens is used to deliver 1.2 J/pulse (1064 nm) and 0.9 J/pulse (532 nm) in a 8 ns laser FWHM pulse produced by 10 Hz Q-switched Nd:YAG laser with spots of a 1.5 mm in diameter moving forward along the work piece. A LSP configuration with experimental results using a pulse density of 2500 pulses/cm 2 and 5000 pulses/cm 2 in 6061-T6 aluminum samples are presented. High level compressive residual stresses are produced using both wavelengths. It has been shown that surface residual stress level is comparable to that achieved by conventional shot peening, but with greater depths. This method can be applied to surface treatment of final metal products.

  8. Novel 755-nm diode laser vs. conventional 755-nm scanned alexandrite laser: Side-by-side comparison pilot study for thorax and axillary hair removal.

    Science.gov (United States)

    Paasch, Uwe; Wagner, Justinus A; Paasch, Hartmut W

    2015-01-01

    Alexandrite (755 nm) and diode lasers (800-810 nm) are commonly used for hair removal. The alexandrite laser technology is somewhat cumbersome whereas new diode lasers are more robust. Recently, alexandrite-like 755 nm wavelength diodes became available. To compare the efficacy, tolerability, and subject satisfaction of a 755 nm diode laser operated in conventional (HR) and non-conventional in-motion (SHR) modes with a conventional scanned alexandrite 755 nm laser for chest and axillary hair removal. A prospective, single-center, proof of principle study was designed to evaluate the safety, efficacy and handling of a 755 nm diode laser system in comparison to a standard alexandrite 755 nm scanning hair removal laser. The new 755 nm diode is suitable to be used in SHR and HR mode and has been tested for its safety, efficacy and handling in a volunteer with success. Overall, both systems showed a high efficacy in hair reduction (88.8% 755 nm diode laser vs. 77.7% 755 nm alexandrite laser). Also, during the study period, no severe adverse effects were reported. The new 755 nm diode laser is as effective and safe as the traditional 755 nm alexandrite laser. Additionally, treatment with the 755 nm diode laser with HR and SHR modes was found to be less painful.

  9. Development of 2-channel (532 nm and 355 nm) mobile LIDAR for mapping particulate matter in the atmosphere

    CSIR Research Space (South Africa)

    Sivakumar, V

    2010-09-01

    Full Text Available In this paper, the authors describe the developmentof 2-Channel (532 nm and 355 nm) mobile LIDAR system for studying atmospheric particulate matter. The system is currently tested in house at the Council for Scientific and Industrial Research...

  10. Realization of 7-cell hollow-core photonic crystal fibers with low loss in the region between 1.4 μm and 2.3 μm

    DEFF Research Database (Denmark)

    Lyngsøe, Jens Kristian; Mangan, Brian Joseph; Jakobsen, C.

    2009-01-01

    Five 7-cell core hollow-core fibers with photonic bandgap spectral positions between 1.4 μm and 2.3 μm were fabricated. The loss follows the ≈ λ-3 dependency previously reported [1] with a minimum measured loss of 9.5 dB/km at 1992 nm.......Five 7-cell core hollow-core fibers with photonic bandgap spectral positions between 1.4 μm and 2.3 μm were fabricated. The loss follows the ≈ λ-3 dependency previously reported [1] with a minimum measured loss of 9.5 dB/km at 1992 nm....

  11. Comparative analysis of the effect of the GaAlAs laser irradiation in 780 nm and 660 nm in the hypersensitive dentin

    International Nuclear Information System (INIS)

    Yuan, Sun Chien

    2003-01-01

    This study was to evaluate and compare the effects of the low intensity in laser radiation among GaAlAs 780 nm and GaAlAs 660 nm. The main proposal is to verify if there is any difference of the effects or results in low intensity laser application treatment of hypersensitive dentin, keeping the same parameters, only differing in wavelength. The samples were distributed in two groups. Group A 90 cases, treated with GaAlAs 780 nm and group B irradiated with GaAlAs 660 nm with a total of 76 cases analyzed. The results of application with GaAlAs 660 nm and GaAlAs 780 nm do not differ statistically. Which means using any one of the irradiation gives the same results. However can be noted that the response of reduction of hypersensitivity is faster with the radiation of GaAlAs 780 nm, but the results after three applications is the same for both types of radiation. (author)

  12. Extreme Ultraviolet Process Optimization for Contact Layer of 14 nm Node Logic and 16 nm Half Pitch Memory Devices

    Science.gov (United States)

    Tseng, Shih-En; Chen, Alek

    2012-06-01

    Extreme ultraviolet (EUV) lithography is considered the most promising single exposure technology at the 27 nm half-pitch node and beyond. The imaging performance of ASML TWINSCAN NXE:3100 has been demonstrated to be able to resolve 26 nm Flash gate layer and 16 nm static random access memory (SRAM) metal layer with a 0.25 numerical aperture (NA) and conventional illumination. Targeting for high volume manufacturing, ASML TWINSCAN NXE:3300B, featuring a 0.33 NA lens with off-axis illumination, will generate a higher contrast aerial image due to improved diffraction order collection efficiency and is expected to reduce target dose via mask biasing. This work performed a simulation to determine how EUV high NA imaging benefits the mask rule check trade-offs required to achieve viable lithography solutions in two device application scenarios: a 14 nm node 6T-SRAM contact layer and a 16 nm half-pitch NAND Flash staggered contact layer. In each application, the three-dimensional mask effects versus Kirchhoff mask were also investigated.

  13. Combined 595-nm and 1,064-nm laser irradiation of recalcitrant and hypertrophic port-wine stains in children and adults.

    Science.gov (United States)

    Alster, Tina S; Tanzi, Elizabeth L

    2009-06-01

    Although pulsed dye laser (PDL) treatment of port-wine stain (PWS) has long been proven safe and effective, incomplete clearance of these vascular malformations can be problematic. In addition, advanced PWS with deeper coloration and tissue hypertrophy can be particularly difficult to treat because of the superficial dermal penetration of 585- to 595-nm light. The purpose of this study was to evaluate the safety and efficacy of a novel device that delivers sequential pulses of 595- and 1,064-nm wavelengths in the treatment of recalcitrant and hypertrophic PWS. Twenty-five children and adults (skin phototypes I-III) with recalcitrant or hypertrophic PWS showing incomplete clearance after 10 prior PDL treatments were included in the study. Successive treatments using a 595-nm PDL and a 1,064-nm neodymium-doped yttrium-aluminum-garnet (Nd:YAG) laser were delivered at 6- to 8-week intervals. Two masked assessors determined clinical improvement of treatment areas using independent evaluation of comparative photographs at baseline and 3 months after treatment using a standard quartile grading scale. The use of dual 595-/1,064-nm wavelengths provided continued improvement of PWS that were previously recalcitrant to ongoing PDL therapy. Side effects were limited to transient erythema, edema, and mild purpura. Rare vesicle formation was observed, with no subsequent scarring or undesirable pigmentary changes. The novel dual 595-nm PDL and 1,064-nm Nd:YAG laser is an effective treatment for PWS that are recalcitrant to PDL therapy alone.

  14. Endovenous laser therapy for occlusion of incompetent saphenous veins using 1940nm

    Science.gov (United States)

    Sroka, Ronald; Pongratz, Thomas; Esipova, Anna; Dikic, Slobodan; Demhasaj, Sahit; Comsa, Florin; Schmedt, Claus-Georg

    2015-07-01

    Objective: Several studies indicate that ELT using wavelengths of high water absorption showed advantages compared to conventional ELT. Thulium-Lasers emit nearby the local absorption maximum of water at 1940nm. In this clinical study the effectiveness, safety and the feasibility of 1940nm-ELT is proven. Materials and Method: A single centric, prospective observational study was performed. 1940nm-laserenergy was applied using radial emitting fibres with continuous pullback (1mm/s). Treatment was performed under anesthesia (general, spinal, tumescent) thus simultaneous miniphlebectomy and ligation of perforators could be applied. Patient and technical details were systematically collected. Evaluation included: standardized questionnaire, clinical examination, color-duplex ultrasonography preoperatively, 3d, 4w, 6m postoperatively, statistic. Results: The 1940nm-ELT study include 55 patients (female/men=34/21, mean age 55y, range 23-90y) treating n=72 vessels. The mean maximum diameter of great saphenous veins (GSV, n=59) was 7.5mm (range 3.7-11.3mm) and of small saphenous veins (SSV, n=13) was 5.3mm (3.0-10.0mm). The mean applied longitudinal endovenous energy density (LEED) was 64.3J/cm (40.3-98.2J/cm) in GSVs and 51.0J/cm (37.6-72.7J/cm) in SSVs. Complete occlusion of the vein without sign of reflux was achieved in 100%. The mean length of non-occluded stump at the sapheno-femoral junction was 6.0mm (1.0-20.0mm). Postoperative reduction of the diameter of GSV was 1.6mm (21.3%) and 2.0mm (37.7%) in SSV. One (1.4%) endovenous heat induced thrombus (EHIT) was observed. Further adverse events were: paresthesia 10/72 (13.9%), ecchymosis 1/72 (1.4%), lymphocele 1/72 (1.4%), hyperpigmentation 1/72 (1.4%). The mean postoperative pain intensity was 1.3 and 1.8 single doses of analgesics were administered. Normal physical activity was reached after 3d (1-21d). Conclusion: 1940nm-ELT using radial light application effectively eliminates the reflux in insufficient saphenous

  15. Radiation Failures in Intel 14nm Microprocessors

    Science.gov (United States)

    Bossev, Dobrin P.; Duncan, Adam R.; Gadlage, Matthew J.; Roach, Austin H.; Kay, Matthew J.; Szabo, Carl; Berger, Tammy J.; York, Darin A.; Williams, Aaron; LaBel, K.; hide

    2016-01-01

    In this study the 14 nm Intel Broadwell 5th generation core series 5005U-i3 and 5200U-i5 was mounted on Dell Inspiron laptops, MSI Cubi and Gigabyte Brix barebones and tested with Windows 8 and CentOS7 at idle. Heavy-ion-induced hard- and catastrophic failures do not appear to be related to the Intel 14nm Tri-Gate FinFET process. They originate from a small (9 m 140 m) area on the 32nm planar PCH die (not the CPU) as initially speculated. The hard failures seem to be due to a SEE but the exact physical mechanism has yet to be identified. Some possibilities include latch-ups, charge ion trapping or implantation, ion channels, or a combination of those (in biased conditions). The mechanism of the catastrophic failures seems related to the presence of electric power (1.05V core voltage). The 1064 nm laser mimics ionization radiation and induces soft- and hard failures as a direct result of electron-hole pair production, not heat. The 14nm FinFET processes continue to look promising for space radiation environments.

  16. Ocular effects of ultraviolet radiation from 295 to 365 nm

    International Nuclear Information System (INIS)

    Pitts, D.G.; Cullen, A.P.; Hacker, P.D.

    1977-01-01

    A 5,000 watt Xe--Hg source and a double monochromator were used to produce 6.6 nm full band-pass ultraviolet (UV) radiation. Pigmented rabbit eyes were exposed to the 6.6 nm band-pass UV radiant energy in 5 nm steps from 295 to 320 nm and at random intervals above 320 nm. Corneal and lenticular damage was assessed and classified with a biomicroscope. Corneal threshold radiant exposure (Hc) rose very rapidly from 0.022 Jcm -2 at 300 nm to 10.99 Jcm -2 at 335 nm. Radiant exposures exceeding 2 x Hc resulted in irreversible corneal damage. Lenticular damage was limited to wavebands above 295 nm. The action spectrum for the lens began at 295 nm and extended to about 315 nm. Permanent lenticular damage occurred at radiant exposure levels approximately twice the threshold for lenticular radiant exposure. The importance in establishing both corneal and lenticular damage criteria is emphasized

  17. Combination of Q-switched and quasi long-pulsed 1064-nm Nd:YAG laser, non-ablative 1450-nm diode laser, and ablative 10 600-nm carbon dioxide fractional laser for enlarged pores.

    Science.gov (United States)

    Cho, Sung Bin; Noh, Seongmin; Lee, Sang Ju; Kang, Jin Moon; Kim, Young Koo; Lee, Ju Hee

    2010-07-01

    Currently, there is no gold standard for the treatment of enlarged facial pores. In this report, we describe a patient with enlarged nasal pores which were treated with a combination of a non-ablative 1450-nm diode laser, a Q-switched and quasi long-pulsed 1064-nm Nd:YAG laser, and an ablative 10 600-nm carbon dioxide fractional laser system. Four months after the final treatment, the condition of the patient's pores had markedly improved, and the patient was satisfied with the results.

  18. 130-nm tunable grating-mirror VCSEL

    DEFF Research Database (Denmark)

    Chung, Il-Sug; Mørk, Jesper

    2014-01-01

    configuration instead of the extended cavity configuration can bring 130-nm tuning range around 1330-nm wavelength. The air-coupled cavity is known to reduce the quantum confinement factor in VCSELs, increasing threshold. In our air-coupled cavity HCG VCSEL case, the very short power penetration length...... in the HCG minimizes this reduction of the quantum confinement factor, not as significant as in the air-coupled cavity DBR VCSEL....

  19. Long-range pulselength scaling of 351nm laser damage thresholds

    Science.gov (United States)

    Foltyn, S. R.; Jolin, L. J.

    1986-12-01

    In a series of experiments incorporating 351nm pulselength of 9, 26, 54, and 625ns, it was found that laser damage thresholds increased as (pulselength)/sup x/, and that the exponent averaged 0.36 and ranged, for different samples, from 0.23 to 0.48. Similar results were obtained when only catastrophic damage was considered. Samples included Al2O3/SiO2 in both AR and HR multilayers, HR's of Sc2O3/SiO2 and HfO2/SiO2, and Al-on-pyrex mirror; 9ns thresholds were between 0.2 to 5.6 J/sq cm. When these data were compared with a wide range of other results - for wavelengths from 0.25 to 10.6 microns and pulselengths down to 4ps - a remarkably consistent picture emerged. Damage thresholds, on average, increase approximately as the cube-root of pulselength from picoseconds to nearly a microsecond, and do so regardless of wavelength or material under test.

  20. Two transistor cluster DICE Cells with the minimum area for a hardened 28-nm CMOS and 65-nm SRAM layout design

    International Nuclear Information System (INIS)

    Stenin, V.Ya.; Stepanov, P.V.

    2015-01-01

    A hardened DICE cell layout design is based on the two spaced transistor clusters of the DICE cell each consisting of four transistors. The larger the distance between these two CMOS transistor clusters, the more robust the hardened DICE SRAM to Single Event Upsets. Some versions of the 28-nm and 65-nm DICE CMOS SRAM block composition have been suggested with minimum cluster distances of 2.27-2.32 mkm. The area of hardened 28-nm DICE CMOS cells is larger than the area of 28-nm 6T CMOS cells by a factor of 2.1 [ru

  1. On-chip measurements of Brownian relaxation of magnetic beads with diameters from 10 nm to 250 nm

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Rizzi, Giovanni; Hansen, Mikkel Fougt

    2013-01-01

    We demonstrate the use of planar Hall effect magnetoresistive sensors for AC susceptibility measurements of magnetic beads with frequencies ranging from DC to 1 MHz. This wide frequency range allows for measuring Brownian relaxation of magnetic beads with diameters ranging from 10 nm to 250 nm....... Brownian relaxation is measured for six different magnetic bead types and their hydrodynamic diameters are determined. The hydrodynamic diameters are found to be within 40% of the nominal bead diameters. We discuss the applicability of the different bead types for volume-based biosensing with respect...... to sedimentation, magnetic trapping, and signal per bead. Among the investigated beads, we conclude that the beads with a nominal diameter of 80 nm are best suited for future on-chip volume-based biosensing experiments using planar Hall effect sensors....

  2. Treatment of inflammatory facial acne vulgaris with combination 595-nm pulsed-dye laser with dynamic-cooling-device and 1,450-nm diode laser.

    Science.gov (United States)

    Glaich, Adrienne S; Friedman, Paul M; Jih, Ming H; Goldberg, Leonard H

    2006-03-01

    The 585-nm pulsed-dye laser and the 1,450-nm diode laser have been found effective for the treatment of mild-to-moderate inflammatory facial acne. This study was designed to evaluate the efficacy and safety of the combined treatment with the 595-nm pulsed-dye laser and the 1,450-nm diode laser for inflammatory facial acne. Fifteen patients with inflammatory facial acne were treated with a combination of the 595-nm pulsed-dye laser and the 1,450-nm diode laser. Patients' subjective response to treatment was evaluated regarding improvement in acne, acne scarring, oiliness, and redness of the skin. All patients had reductions in acne lesion counts. Mean lesion counts decreased 52% (P < 0.01), 63% (P < 0.01), and 84% (P < 0.01) after one, two, and three treatments, respectively. Patients described moderate-to-marked improvement in acne, acne scarring, and post-inflammatory erythema. Adverse effects were limited to mild, transient erythema. The combination of the 595-nm pulsed-dye laser and the 1,450-nm diode laser is safe and effective for the treatment of inflammatory facial acne, acne scarring, and post-inflammatory erythema. 2005 Wiley-Liss, Inc.

  3. Citrus tristeza virus-based RNAi in citrus plants induces gene silencing in Diaphorina citri, a phloem-sap sucking insect vector of citrus greening disease (Huanglongbing).

    Science.gov (United States)

    Hajeri, Subhas; Killiny, Nabil; El-Mohtar, Choaa; Dawson, William O; Gowda, Siddarame

    2014-04-20

    A transient expression vector based on Citrus tristeza virus (CTV) is unusually stable. Because of its stability it is being considered for use in the field to control Huanglongbing (HLB), which is caused by Candidatus Liberibacter asiaticus (CLas) and vectored by Asian citrus psyllid, Diaphorina citri. In the absence of effective control strategies for CLas, emphasis has been on control of D. citri. Coincident cohabitation in phloem tissue by CLas, D. citri and CTV was exploited to develop a novel method to mitigate HLB through RNA interference (RNAi). Since CTV has three RNA silencing suppressors, it was not known if CTV-based vector could induce RNAi in citrus. Yet, expression of sequences targeting citrus phytoene desaturase gene by CTV-RNAi resulted in photo-bleaching phenotype. CTV-RNAi vector, engineered with truncated abnormal wing disc (Awd) gene of D. citri, induced altered Awd expression when silencing triggers ingested by feeding D. citri nymphs. Decreased Awd in nymphs resulted in malformed-wing phenotype in adults and increased adult mortality. This impaired ability of D. citri to fly would potentially limit the successful vectoring of CLas bacteria between citrus trees in the grove. CTV-RNAi vector would be relevant for fast-track screening of candidate sequences for RNAi-mediated pest control. Copyright © 2014. Published by Elsevier B.V.

  4. Study of drain-extended NMOS under electrostatic discharge stress in 28 nm and 40 nm CMOS process

    Science.gov (United States)

    Wang, Weihuai; Jin, Hao; Dong, Shurong; Zhong, Lei; Han, Yan

    2016-02-01

    Researches on the electrostatic discharge (ESD) performance of drain-extended NMOS (DeNMOS) under the state-of-the-art 28 nm and 40 nm bulk CMOS process are performed in this paper. Three distinguishing phases of avalanche breakdown stage, depletion region push-out stage and parasitic NPN turn on stage of the gate-grounded DeNMOS (GG-DeNMOS) fabricated under 28 nm CMOS process measured with transmission line pulsing (TLP) test are analyzed through TCAD simulations and tape-out silicon verification detailedly. Damage mechanisms and failure spots of GG-DeNMOS under both CMOS processes are thermal breakdown of drain junction. Improvements based on the basic structure adjustments can increase the GG-DeNMOS robustness from original 2.87 mA/μm to the highest 5.41 mA/μm. Under 40 nm process, parameter adjustments based on the basic structure have no significant benefits on the robustness improvements. By inserting P+ segments in the N+ implantation of drain or an entire P+ strip between the N+ implantation of drain and polysilicon gate to form the typical DeMOS-SCR (silicon-controlled rectifier) structure, the ESD robustness can be enhanced from 1.83 mA/μm to 8.79 mA/μm and 29.78 mA/μm, respectively.

  5. Bilirubin isomer distribution in jaundiced neonates during phototherapy with LED light centered at 497 nm (turquoise) vs. 459 nm (blue).

    Science.gov (United States)

    Ebbesen, Finn; Madsen, Poul H; Vandborg, Pernille K; Jakobsen, Lasse H; Trydal, Torleif; Vreman, Hendrik J

    2016-10-01

    Phototherapy using blue light is the treatment of choice worldwide for neonatal hyperbilirubinemia. However, treatment with turquoise light may be a desirable alternative. Therefore, the aim of this randomized, controlled study was to compare the bilirubin isomer distribution in serum of jaundiced neonates after 24 h of therapy with narrow-band (LED) light centered at 497 nm (turquoise) vs. 459 nm (blue), of essentially equal irradiance. Eighty-three neonates (≥33 wk gestational age) with uncomplicated hyperbilirubinemia were included in the study. Forty neonates were exposed to light centered at 497 nm and 43 infants with light centered at 459 nm. Irradiances were 5.2 × 10(15) and 5.1 × 10(15) photons/cm(2)/s, respectively. After 24 h of treatment no significant differences in serum concentrations of total bilirubin isomers and Z,Z-bilirubin were observed between the 2 groups. Interestingly, concentrations of Z,E-bilirubin, and thus also total bilirubin isomers formed during therapy, were highest for infants receiving light centered at 459 nm, while the concentration of E,Z-bilirubin was highest for those receiving light centered at 497 nm. No significant difference was found between concentrations of E,Z-lumirubin. Therapy with LED light centered at 497 nm vs. 459 nm, applied with equal irradiance on the infants, resulted in a different distribution of bilirubin isomers in serum.

  6. Cadherin-23 may be dynamic in hair bundles of the model sea anemone Nematostella vectensis.

    Directory of Open Access Journals (Sweden)

    Pei-Ciao Tang

    Full Text Available Cadherin 23 (CDH23, a component of tip links in hair cells of vertebrate animals, is essential to mechanotransduction by hair cells in the inner ear. A homolog of CDH23 occurs in hair bundles of sea anemones. Anemone hair bundles are located on the tentacles where they detect the swimming movements of nearby prey. The anemone CDH23 is predicted to be a large polypeptide featuring a short exoplasmic C-terminal domain that is unique to sea anemones. Experimentally masking this domain with antibodies or mimicking this domain with free peptide rapidly disrupts mechanotransduction and morphology of anemone hair bundles. The loss of normal morphology is accompanied, or followed by a decrease in F-actin in stereocilia of the hair bundles. These effects were observed at very low concentrations of the reagents, 0.1-10 nM, and within minutes of exposure. The results presented herein suggest that: (1 the interaction between CDH23 and molecular partners on stereocilia of hair bundles is dynamic and; (2 the interaction is crucial for normal mechanotransduction and morphology of hair bundles.

  7. SOLAR VARIABILITY FROM 240 TO 1750 nm IN TERMS OF FACULAE BRIGHTENING AND SUNSPOT DARKENING FROM SCIAMACHY

    International Nuclear Information System (INIS)

    Pagaran, J.; Weber, M.; Burrows, J.

    2009-01-01

    The change of spectral decomposition of the total radiative output on various timescales of solar magnetic activity is of large interest to terrestrial and solar-stellar atmosphere studies. Starting in 2002, SCIAMACHY was the first satellite instrument to observe daily solar spectral irradiance (SSI) continuously from 230 nm (UV) to 1750 nm (near-infrared; near-IR). In order to address the question of how much UV, visible (vis), and IR spectral regions change on 27 day and 11 year timescales, we parameterize short-term SSI variations in terms of faculae brightening (Mg II index) and sunspot darkening (photometric sunspot index) proxies. Although spectral variations above 300 nm are below 1% and, therefore, well below the accuracy of absolute radiometric calibration, relative accuracy for short-term changes is shown to be in the per mill range. This enables us to derive short-term spectral irradiance variations from the UV to the near-IR. During Halloween solar storm in 2003 with a record high sunspot area, we observe a reduction of 0.3% in the near-IR to 0.5% in the vis and near-UV. This is consistent with a 0.4% reduction in total solar irradiance (TSI). Over an entire 11 year solar cycle, SSI variability covering simultaneously the UV, vis, and IR spectral regions have not been directly observed so far. Using variations of solar proxies over solar cycle 23, solar cycle spectral variations have been estimated using scaling factors that best matched short-term variations of SCIAMACHY. In the 300-400 nm region, which strongly contributes to TSI solar cycle change, a contribution of 34% is derived from SCIAMACHY observations, which is lower than the reported values from SUSIM satellite data and the empirical SATIRE model. The total UV contribution (below 400 nm) to TSI solar cycle variations is estimated to be 55%.

  8. Removal of sulfamethoxazole, ibuprofen and nitrobenzene by UV and UV/chlorine processes: A comparative evaluation of 275 nm LED-UV and 254 nm LP-UV.

    Science.gov (United States)

    Kwon, Minhwan; Yoon, Yeojoon; Kim, Seonbaek; Jung, Youmi; Hwang, Tae-Mun; Kang, Joon-Wun

    2018-05-15

    The aim of this study is to evaluate the micropollutant removal capacity of a 275 nm light-emitting diode (LED)-UV/chlorine system. The sulfamethoxazole, ibuprofen, and nitrobenzene removal efficiencies of this system were compared with those of a conventional 254 nm low-pressure (LP)-UV system as a function of the UV dose. In a direct photolysis system, the photon reactivity of sulfamethoxazole is higher than that of nitrobenzene and ibuprofen at both wavelengths. The molar absorption coefficients and quantum yields of each micropollutant were as follows: sulfamethoxazole (ε SMX, 275 nm protonated  = 17,527 M -1  cm -1 , Φ SMX, 275 nm protonated  = 0.239, ε SMX, 275 nm deprotonated  = 8430 M -1  cm -1 , and Φ SMX, 275 nm deprotonated  = 0.026), nitrobenzene (ε NB, 275 nm  = 7176 M -1  cm -1 and Φ NB, 275 nm  = 0.057), and ibuprofen (ε NB, 275 nm  = 200 M -1  cm -1 and Φ IBF, 275 nm  = 0.067). The photon reactivity of chlorine species, i.e., HOCl and OCl-, were determined at 275 nm (ε HOCl, 275 nm  = 28 M -1  cm -1 , Φ HOCl, 275 nm  = 1.97, ε OCl-, 275 nm  = 245 M -1  cm -1 , and Φ OCl-, 275 nm  = 0.8), which indicate that the decomposition rate of OCl - is higher and that of HOCl is lower by 275 nm photolysis than that by 254 nm photolysis (ε HOCl, 254 nm  = 60 M -1  cm -1 , Φ HOCl, 254 nm  = 1.46, ε OCl-, 254 nm  = 58 M -1  cm -1 , and Φ OCl-, 254 nm  = 1.11). In the UV/chlorine system, the removal rates of ibuprofen and nitrobenzene were increased by the formation of OH and reactive chlorine species. The 275-nm LED-UV/chlorine system has higher radical yields at pH 7 and 8 than the 254 nm LP-UV/chlorine system. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Cascaded a-cut Nd:YVO4 self-Raman with second-Stokes laser at 1313 nm

    Science.gov (United States)

    Xie, Zhi; Duan, Yanmin; Guo, Junhong; Huang, Xiaohong; Yan, Lifen; Zhu, Haiyong

    2017-11-01

    A diode-end-pumped, acousto-optic Q-switched second-Stokes self-Raman laser at 1313 nm was demonstrated in a common a-cut Nd:YVO4 crystal, with the primary Raman shift of 890 cm-1. At the incident pump power of 17.1 W, the maximum average output power up to 2.51 W and pulse width of 5 ns for second-Stokes were obtained with the pulse repetition frequency of 50 kHz. The slope efficiency and conversion efficiency with respect to the incident pump power are about 23.7% and 14.7%. The efficient output should be attributed to suitable transmittance of the output coupler used.

  10. 16.7 W 885 nm diode-side-pumped actively Q -switched Nd:YAG/YVO4 intracavity Raman laser at 1176 nm

    International Nuclear Information System (INIS)

    Jiang, Pengbo; Zhang, Guizhong; Liu, Jian; Ding, Xin; Sheng, Quan; Sun, Bing; Shi, Rui; Wu, Liang; Yao, Jianquan; Yu, Xuanyi; Wang, Rui

    2017-01-01

    We proposed and experimentally demonstrated the generation of high-power 1176 nm Stokes wave by frequency shifting of a 885 nm diode-side-pumped Nd:YAG laser using a YVO 4 crystal in a Z -shaped cavity configuration. Employing the 885 nm diode-side-pumped scheme and the Z -shaped cavity, for the first time to our knowledge, we realized the thermal management effectively, achieving excellent 1176 nm Stokes wave consequently. With an incident pump power of ∼190.0 W, a maximum average output power of 16.7 W was obtained at the pulse repetition frequency of 10 kHz. The pulse duration and spectrum linewidth of the Stokes wave at the maximum output power were 20.3 ns and ∼0.08 nm, respectively. (paper)

  11. Sb surfactant effect on GaInAs/GaAs highly strained quantum well lasers emitting at 1200 nm range grown by molecular beam epitaxy

    International Nuclear Information System (INIS)

    Kageyama, Takeo; Miyamoto, Tomoyuki; Ohta, Masataka; Matsuura, Tetsuya; Matsui, Yasutaka; Furuhata, Tatsuya; Koyama, Fumio

    2004-01-01

    A surfactant effect of antimony (Sb) on highly strained GaInAs quantum wells (QWs) was studied by molecular beam epitaxy. Noticeable improvement of the photoluminescence (PL) was observed by adding the dilute Sb. The QWs showed an increased PL intensity and narrow linewidth of 23 meV for the wavelength range up to 1180 nm. An atomic force microscope study showed a flattened surface morphology by the introduction of the Sb. Broad-area lasers with a GaInAsSb/GaAs double-QW active layer emitting at 1170 nm showed a low threshold current density of 125 A/cm 2 per well for an infinite cavity length

  12. Drought monitoring with soil moisture active passive (SMAP) measurements

    Science.gov (United States)

    Mishra, Ashok; Vu, Tue; Veettil, Anoop Valiya; Entekhabi, Dara

    2017-09-01

    Recent launch of space-borne systems to estimate surface soil moisture may expand the capability to map soil moisture deficit and drought with global coverage. In this study, we use Soil Moisture Active Passive (SMAP) soil moisture geophysical retrieval products from passive L-band radiometer to evaluate its applicability to forming agricultural drought indices. Agricultural drought is quantified using the Soil Water Deficit Index (SWDI) based on SMAP and soil properties (field capacity and available water content) information. The soil properties are computed using pedo-transfer function with soil characteristics derived from Harmonized World Soil Database. The SMAP soil moisture product needs to be rescaled to be compatible with the soil parameters derived from the in situ stations. In most locations, the rescaled SMAP information captured the dynamics of in situ soil moisture well and shows the expected lag between accumulations of precipitation and delayed increased in surface soil moisture. However, the SMAP soil moisture itself does not reveal the drought information. Therefore, the SMAP based SWDI (SMAP_SWDI) was computed to improve agriculture drought monitoring by using the latest soil moisture retrieval satellite technology. The formulation of SWDI does not depend on longer data and it will overcome the limited (short) length of SMAP data for agricultural drought studies. The SMAP_SWDI is further compared with in situ Atmospheric Water Deficit (AWD) Index. The comparison shows close agreement between SMAP_SWDI and AWD in drought monitoring over Contiguous United States (CONUS), especially in terms of drought characteristics. The SMAP_SWDI was used to construct drought maps for CONUS and compared with well-known drought indices, such as, AWD, Palmer Z-Index, sc-PDSI and SPEI. Overall the SMAP_SWDI is an effective agricultural drought indicator and it provides continuity and introduces new spatial mapping capability for drought monitoring. As an

  13. Comparative Study of the Detection of Chromium Content in Rice Leaves by 532 nm and 1064 nm Laser-Induced Breakdown Spectroscopy

    Directory of Open Access Journals (Sweden)

    Jiyu Peng

    2018-02-01

    Full Text Available Fast detection of toxic metals in crops is important for monitoring pollution and ensuring food safety. In this study, laser-induced breakdown spectroscopy (LIBS was used to detect the chromium content in rice leaves. We investigated the influence of laser wavelength (532 nm and 1064 nm excitation, along with the variations of delay time, pulse energy, and lens-to-sample distance (LTSD, on the signal (sensitivity and stability and plasma features (temperature and electron density. With the optimized experimental parameters, univariate analysis was used for quantifying the chromium content, and several preprocessing methods (including background normalization, area normalization, multiplicative scatter correction (MSC transformation and standardized normal variate (SNV transformation were used to further improve the analytical performance. The results indicated that 532 nm excitation showed better sensitivity than 1064 nm excitation, with a detection limit around two times lower. However, the prediction accuracy for both excitation wavelengths was similar. The best result, with a correlation coefficient of 0.9849, root-mean-square error of 3.89 mg/kg and detection limit of 2.72 mg/kg, was obtained using the SNV transformed signal (Cr I 425.43 nm induced by 532 nm excitation. The results indicate the inspiring capability of LIBS for toxic metals detection in plant materials.

  14. A high power, continuous-wave, single-frequency fiber amplifier at 1091 nm and frequency doubling to 545.5 nm

    International Nuclear Information System (INIS)

    Stappel, M; Steinborn, R; Kolbe, D; Walz, J

    2013-01-01

    We present a high power single-frequency ytterbium fiber amplifier system with an output power of 30 W at 1091 nm. The amplifier system consists of two stages, a preamplifier stage in which amplified spontaneous emission is efficiently suppressed (>40 dB) and a high power amplifier with an efficiency of 52%. Two different approaches to frequency doubling are compared. We achieve 8.6 W at 545.5 nm by single-pass frequency doubling in a MgO-doped periodically poled stoichiometric LiTaO 3 crystal and up to 19.3 W at 545.5 nm by frequency doubling with a lithium-triborate crystal in an external enhancement cavity. (paper)

  15. Trends in nanosecond melanosome microcavitation up to 1540 nm

    Science.gov (United States)

    Schmidt, Morgan S.; Kennedy, Paul K.; Noojin, Gary D.; Vincelette, Rebecca L.; Thomas, Robert J.; Rockwell, Benjamin A.

    2015-09-01

    Thresholds for microcavitation of bovine and porcine melanosomes were previously reported, using single nanosecond (ns) laser pulses in the visible (532 nm) and the near-infrared (NIR) from 1000 to 1319 nm. Here, we report average radiant exposure thresholds for bovine melanosome microcavitation at additional NIR wavelengths up to 1540 nm, which range from ˜0.159 J/cm2 at 800 nm to 4.5 J/cm2 at 1540 nm. Melanosome absorption coefficients were also estimated, and decreased with increasing wavelength. These values were compared to retinal pigment epithelium coefficients, and to water absorption, over the same wavelength range. Corneal total intraocular energy retinal damage threshold values were estimated and compared to the previous (2007) and recently changed (2014) maximum permissible exposure (MPE) safe levels. Results provide additional data that support the recent changes to the MPE levels, as well as the first microcavitation data at 1540 nm, a wavelength for which melanosome microcavitation may be an ns-pulse skin damage mechanism.

  16. Experimental Studies of Simultaneous 351 nm and 527 nm Laser Beam Interactions in a Long Scalelength Plasma

    International Nuclear Information System (INIS)

    Moody, J D; Divol, L; Glenzer, S H; MacKinnon, A J; Froula, D H; Gregori, G; Kruer, W L; Suter, L J; Williams, E A; Bahr, R; Seka, W

    2003-01-01

    We describe experiments investigating the simultaneous backscattering from 351 nm (3w) and 527 nm (2w) interaction beams in a long scalelength laser-produced plasma for intensities (le) 1 x 10 15 W/cm 2 . Measurements show comparable scattering fractions for both color probe beams. Time resolved spectra of stimulated Raman and Brillouin scattering (SRS and SBS) indicate the effects of laser intensity and smoothing as well as plasma composition and parameters on the scattering levels

  17. Clock Gating Based Energy Efficient and Thermal Aware Design for Vedic Equation Solver on 28nm and 40nm FPGA

    DEFF Research Database (Denmark)

    Pandey, Bishwajeet; Pandey, Sujeet; Sharma, Shivani

    2016-01-01

    In this paper, we are integrating clock gating in design of energy efficient equation solver circuits based on Vedic mathematics. Clock gating is one of the best energy efficient techniques. The Sutra 'SunyamSamyasamuccaye' says thatif sum of numerator and sum of denominator is same then we can e......, 94.54% for 1800MHz, and 94.02% for 2.2GHz, when we use gated clock instead of un gated one on 40nm FPGA and temperature is 329.85K. Power consumption in 28nm FPGA is less than 40nm FPGA....

  18. Diode laser (980nm) cartilage reshaping

    Science.gov (United States)

    El Kharbotly, A.; El Tayeb, T.; Mostafa, Y.; Hesham, I.

    2011-03-01

    Loss of facial or ear cartilage due to trauma or surgery is a major challenge to the otolaryngologists and plastic surgeons as the complicated geometric contours are difficult to be animated. Diode laser (980 nm) has been proven effective in reshaping and maintaining the new geometric shape achieved by laser. This study focused on determining the optimum laser parameters needed for cartilage reshaping with a controlled water cooling system. Harvested animal cartilages were angulated with different degrees and irradiated with different diode laser powers (980nm, 4x8mm spot size). The cartilage specimens were maintained in a deformation angle for two hours after irradiation then released for another two hours. They were serially measured and photographed. High-power Diode laser irradiation with water cooling is a cheep and effective method for reshaping the cartilage needed for reconstruction of difficult situations in otorhinolaryngologic surgery. Key words: cartilage,diode laser (980nm), reshaping.

  19. Comparison of the effects of 665 nm low level diode Laser Hat versus and a combination of 665 nm and 808nm low level diode Laser Scanner of hair growth in androgenic alopecia.

    Science.gov (United States)

    Barikbin, Behrooz; Khodamrdi, Zeinab; Kholoosi, Leila; Akhgri, Mohammad Reza; Haj Abbasi, Majid; Hajabbasi, Mojgan; Razzaghi, Zahra; Akbarpour, Samaneh

    2017-05-17

    This study aimed to evaluate the effectiveness of a combined set of low level diode laser scanner (665 nm and 808nm) on hair growth, and assessment of safety and effectiveness of a new laser scanner on hair growth treatment procedure in androgenic alopecia. 90 patients (18 to 70 years) with androgenic alopecia were randomized into three groups. The first group (n=30) received 655 nm red light using laser hat, the second group (n=30) received 655 nm red laser plus 808 nm infrared laser using a laser scanner of hair growth device (with the patent number: 77733) and the third group (n=30) received no laser as the control group. Patients in laser scanner group had better results and showed a higher increase in terminal hair density compared with laser hat group (mean of 9.61 versus 9.16 per cm 2 ). We found significant decrease in terminal hair density from baseline in control group (mean -1.8 per cm 2 , plaser scanner of the hair growth group compared with laser hat and the control group. The study showed that treatment with new laser devise had a promising result without any observable adverse effects.

  20. Liposucción con diodo láser 980-nm (LSDL 980-nm: optimización de protocolo seguro en cirugía de contorno corporal Body contouring using laser diode 980-nm (LSDL 980-nm assisted lipolysis: a safe procedure

    Directory of Open Access Journals (Sweden)

    P. Centurión

    2011-12-01

    Full Text Available La disponibilidad en el mercado de una gran gama de equipos de láser de diferentes potencias y longitudes de onda para su aplicación en el tejido graso, así como la existencia de diversos trabajos científicos sobre el tema con resultados opuestos, han causado gran confusión y dudas sobre la técnica de láser-lipolisis entre los cirujanos plásticos. Presentamos un protocolo quirúrgico de liposucción con diodo-láser de 980-nm (LSDL 980-nm aplicado en 240 pacientes. Evaluamos la seguridad de la técnica según el índice de complicaciones sufrido, así como la evolución en el post-operatorio de los pacientes tratados. Empleamos un equipo diodo-láser-980 nm (ORlight ®, cuya energía llevamos a través de una fibra de 600 μm. Esto se traduce en la aplicación de 99 J por cada cm² de área tratada, con un espesor de hasta 4 cm de tejido adiposo subcutáneo. No tuvimos complicaciones mayores, tipo quemaduras y entre las complicaciones menores, que fueron de un 48.33 % (116 pacientes, encontramos equímosis mínimas (menos del 2 % de superficie corporal. El tiempo que los pacientes requirieron para controlar el dolor postoperatorio fue de entre 1 y 2 días. Consideramos importante la incorporación de la LSDL-980 nm por ser una técnica menos traumática y con bajo índice de complicaciones, que reduce el periodo de recuperación de los pacientes, provoca una importante retracción de la piel y disminuye el dolor postoperatorio.The availability of multiple laser systems on the market with different power and wavelengths and the existence of several scientific papers with contradictory presents, have created great confusion and doubts among plastic surgeons with regard to the laser lipolysis technique. We report a surgical protocol for liposuction diode laser-980 nm (LSDL-980 nm applied to 240 patients. We evaluate the security of the technique according to the complication rate and the postoperative development of patients submitted to

  1. Nearly fully compressed 1053 nm pulses directly obtained from 800 nm laser-seeded photonic crystal fiber below zero dispersion point

    Science.gov (United States)

    Refaeli, Zaharit; Shamir, Yariv; Ofir, Atara; Marcus, Gilad

    2018-02-01

    We report a simple robust and broadly spectral-adjustable source generating near fully compressed 1053 nm 62 fs pulses directly out of a highly-nonlinear photonic crystal fiber. A dispersion-nonlinearity balance of 800 nm Ti:Sa 20 fs pulses was obtained initially by negative pre-chirping and then launching the pulses into the fibers' normal dispersion regime. Following a self-phase modulation spectral broadening, some energy that leaked below the zero dispersion point formed a soliton whose central wavelength could be tuned by Self-Frequency-Raman-Shift effect. Contrary to a common approach of power, or, fiber-length control over the shift, here we continuously varied the state of polarization, exploiting the Raman and Kerr nonlinearities responsivity for state of polarization. We obtained soliton pulses with central wavelength tuned over 150 nm, spanning from well below 1000 to over 1150 nm, of which we could select stable pulses around the 1 μm vicinity. With linewidth of > 20 nm FWHM Gaussian-like temporal-shape pulses with 62 fs duration and near flat phase structure we confirmed high quality pulse source. We believe such scheme can be used for high energy or high power glass lasers systems, such as Nd or Yb ion-doped amplifiers and systems.

  2. Laser-Assisted Liposuction Using the Novel 1,444-nm Nd:YAG Laser for the Treatment of Gynecomastia: A Pilot Study.

    Science.gov (United States)

    Yoo, Kwang Ho; Bae, Jung Min; Won, Chae Young; Chung, Yu Seok; Goo, Boncheol; Rho, Yong Kwan; Kim, Gyong Moon; Lee, Jongwon; Ahn, Byeong Heon; Kim, Beom Joon

    2015-01-01

    Laser-assisted liposuction (LAL) is currently widely used to reduce localized fat. A novel Nd:YAG laser that uses a wavelength of 1,444 nm, which is better absorbed by fat, has recently been introduced. In this study, we investigated the efficacy of 1,444-nm Nd:YAG LAL for the treatment of gynecomastia. Thirteen Korean male patients (20-28 years, mean age 23 years) diagnosed with gynecomastia were enrolled in this study. All patients were treated by LAL with 1,444-nm Nd:YAG laser (100 µs pulse width, 40 Hz frequency, 300 mJ pulse energy and 12 W power with continuous emission) after tumescent anesthetic infiltration and were then evaluated. Outcome was assessed using the following 4 methods: (1) clinical assessment with photographs obtained before and 12 weeks after LAL treatment, (2) comparison of pre- and postoperative patient chest circumferences, (3) computed tomography (CT) scans to evaluate changes in breast thickness and (4) a patient satisfaction survey at the end of the study. After 12 weeks, most patients (84.5%) showed an improvement greater than 50%. Mean chest circumference was significantly reduced from 109.6 ± 8.2 to 101.2 ± 4.4 cm 12 weeks after LAL (p Gynecomastia can be safely treated with 1,444-nm Nd:YAG LAL to reduce fatty tissue and total breast volume. © 2015 S. Karger AG, Basel.

  3. Liquid Carbon Reflectivity at 19 nm

    Directory of Open Access Journals (Sweden)

    Riccardo Mincigrucci

    2015-01-01

    Full Text Available We hereby report on a pump-probe reflectivity experiment conducted on amorphous carbon, using a 780 nm laser as a pump and a 19 nm FEL emission as probe. Measurements were performed at 50 degrees with respect to the surface normal to have an un-pumped reflectivity higher than 0.5%. A sub-10 fs time synchronization error could be obtained exploiting the nearly jitter-free capabilities of FERMI. EUV FEL-based experiments open the way to study the behaviour of a liquid carbon phase being unaffected by plasma screening.

  4. Enhancement of 800 nm upconversion emission in a thulium doped tellurite microstructured fiber pumped by a 1560 nm femtosecond fiber laser

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Zhixu; Zheng, Kezhi [State Key Laboratory of Optical Fiber and Cable Manufacture Technology, Yangtze Optical Fiber and Cable Joint Stock Limited Company, Wuhan 430073 (China); State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012 (China); Yao, Chuanfei; Wang, Shunbin; Qin, Guanshi, E-mail: qings@jlu.edu.cn; Qin, Weiping, E-mail: wpqin@jlu.edu.cn [State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012 (China); Xiong, Liangming; Luo, Jie; Lv, Dajuan [State Key Laboratory of Optical Fiber and Cable Manufacture Technology, Yangtze Optical Fiber and Cable Joint Stock Limited Company, Wuhan 430073 (China); Ohishi, Yasutake [Research Center for Advanced Photon Technology, Toyota Technological Institute, 2-12-1 Hisakata, Tempaku, Nagoya 468–8511 (Japan)

    2016-04-28

    We report enhanced upconversion (UC) fluorescence in Tm{sup 3+} doped tellurite microstructured fibers (TDTMFs) fabricated by using a rod-in-tube method. Under the pumping of a 1560 nm femtosecond fiber laser, ultrabroadband supercontinuum light expanding from ∼1050 to ∼2700 nm was generated in a 4 cm long TDTMF. Simultaneously, intense 800 nm UC emission from the {sup 3}H{sub 4} → {sup 3}H{sub 6} transition of Tm{sup 3+} was observed in the same TDTMF. Compared to that pumped by a 1560 nm continuous wave fiber laser, the UC emission intensity was enhanced by ∼4.1 times. The enhancement was due to the spectral broadening in the TDTMF under the pumping of the 1560 nm femtosecond fiber laser.

  5. Measurements of the Weak UV Absorptions of Isoprene and Acetone at 261–275 nm Using Cavity Ringdown Spectroscopy for Evaluation of a Potential Portable Ringdown Breath Analyzer

    Science.gov (United States)

    Sahay, Peeyush; Scherrer, Susan T.; Wang, Chuji

    2013-01-01

    The weak absorption spectra of isoprene and acetone have been measured in the wavelength range of 261–275 nm using cavity ringdown spectroscopy. The measured absorption cross-sections of isoprene in the wavelength region of 261–266 nm range from 3.65 × 10−21 cm2·molecule−1 at 261 nm to 1.42 × 10−21 cm2·molecule−1 at 266 nm; these numbers are in good agreement with the values reported in the literature. In the longer wavelength range of 270–275 nm, however, where attractive applications using a single wavelength compact diode laser operating at 274 nm is located, isoprene has been reported in the literature to have no absorption (too weak to be detected). Small absorption cross-sections of isoprene in this longer wavelength region are measured using cavity ringdown spectroscopy for the first time in this work, i.e., 6.20 × 10−23 cm2·molecule−1 at 275 nm. With the same experimental system, wavelength-dependent absorption cross-sections of acetone have also been measured. Theoretical detection limits of isoprene and comparisons of absorbance of isoprene, acetone, and healthy breath gas in this wavelength region are also discussed. PMID:23803787

  6. A possible upgrade of FLASH for harmonic lasing down to 1.3 nm

    International Nuclear Information System (INIS)

    Schneidmiller, E.A.; Yurkov, M.V.

    2012-10-01

    We propose the 3rd harmonic lasing in a new FLASH undulator as a way to produce intense, narrow-band, and stable SASE radiation down to 1.3 nm with the present accelerator energy of 1.25 GeV. To provide optimal conditions for harmonic lasing, we suggest to suppress the fundamental with the help of a special set of phase shifters. We rely on the standard technology of gap-tunable planar hybrid undulators, and choose the period of 2.3 cm and the minimum gap of 0.9 cm; total length of the undulator system is 34.5 m. With the help of numerical simulations we demonstrate that the 3rd harmonic lasing at 1.3 nm provides peak power at a gigawatt level and the narrow intrinsic bandwidth, 0.1% (FWHM). Pulse duration can be controlled in the range of a few tens of femtoseconds, and the peak brilliance reaches the value of 10 31 photons/(s mrad 2 mm 2 0.1% BW). With the given undulator design, a standard option of lasing at the fundamental wavelength to saturation is possible through the entire water window and at longer wavelengths. In this paper we briefly consider additional options such as polarization control, bandwidth reduction, self-seeding, X-ray pulse compression, and two-color operation. We also discuss possible technical issues and backup solutions.

  7. A possible upgrade of FLASH for harmonic lasing down to 1.3 nm

    Energy Technology Data Exchange (ETDEWEB)

    Schneidmiller, E.A.; Yurkov, M.V.

    2012-10-15

    We propose the 3rd harmonic lasing in a new FLASH undulator as a way to produce intense, narrow-band, and stable SASE radiation down to 1.3 nm with the present accelerator energy of 1.25 GeV. To provide optimal conditions for harmonic lasing, we suggest to suppress the fundamental with the help of a special set of phase shifters. We rely on the standard technology of gap-tunable planar hybrid undulators, and choose the period of 2.3 cm and the minimum gap of 0.9 cm; total length of the undulator system is 34.5 m. With the help of numerical simulations we demonstrate that the 3rd harmonic lasing at 1.3 nm provides peak power at a gigawatt level and the narrow intrinsic bandwidth, 0.1% (FWHM). Pulse duration can be controlled in the range of a few tens of femtoseconds, and the peak brilliance reaches the value of 10{sup 31} photons/(s mrad{sup 2} mm{sup 2} 0.1% BW). With the given undulator design, a standard option of lasing at the fundamental wavelength to saturation is possible through the entire water window and at longer wavelengths. In this paper we briefly consider additional options such as polarization control, bandwidth reduction, self-seeding, X-ray pulse compression, and two-color operation. We also discuss possible technical issues and backup solutions.

  8. Absolute frequency atlas from 915 nm to 985 nm based on laser absorption spectroscopy of iodine

    Science.gov (United States)

    Nölleke, Christian; Raab, Christoph; Neuhaus, Rudolf; Falke, Stephan

    2018-04-01

    This article reports on laser absorption spectroscopy of iodine gas between 915 nm and 985 nm. This wavelength range is scanned utilizing a narrow linewidth and mode-hop-free tunable diode-laser whose frequency is actively controlled using a calibrated wavelength meter. This allows us to provide an iodine atlas that contains almost 10,000 experimentally observed reference lines with an uncertainty of 50 MHz. For common lines, good agreement is found with a publication by Gerstenkorn and Luc (1978). The new rich dataset allows existing models of the iodine molecule to be refined and can serve as a reference for laser frequency calibration and stabilization.

  9. 1300 nm and 890 nm OCT images of oral cancer tissue engineered models and biopsy samples offer complimentary performance (Conference Presentation)

    Science.gov (United States)

    Boadi, Joseph; Byers, Robert A.; Fernandes, Jon; Mittar, Shweta; Hearnden, Vanessa; Lu, Zenghai; MacNeil, Sheila; Thornhill, Martin; Murdoch, Craig; Hunter, Keith D.; McKechnie, Alasdair; Matcher, Stephen J.

    2016-02-01

    OCT has demonstrated great potential to non-invasively detect oral epithelial cancers, potentially guiding biopsy and surgical resection. On non-ophthalmic tissues the preferred illumination wavelength is 1300 nm. Previous studies on skin have shown that useful image data can also be obtained at shorter wavelengths, with systems at 1060 nm and 820 nm offering reduced depth penetration but higher contrast. Here we apply a similar comparison to tissue engineered models of oral cancer and also to human biopsy samples, generally finding a similar trend. 1300 nm multi-beam OCT (Michelson Diagnostics EX1301) visualises stromal structures and surface keratin more clearly, providing useful image contrast down to around 1 mm. This system was compared with an ultra-high resolution home-built system operating at 890 nm (2.5 micron resolution vs 7.5 micron axial resolution for the EX1301). The UHR system reveals epithelial features more clearly, especially in the DOK pre-invasive cell line model and the biopsy samples. The relative effects of center wavelength vs axial resolution in generating the differential, wavelength-dependent contrast are assessed and the OCT biopsy images are compared with contemporary histology.

  10. High-efficency stable 213-nm generation for LASIK application

    Science.gov (United States)

    Wang, Zhenglin; Alameh, Kamal; Zheng, Rong

    2005-01-01

    213nm Solid-state laser technology provides an alternative method to replace toxic excimer laser in LASIK system. In this paper, we report a compact fifth harmonic generation system to generate high pulse energy 213nm laser from Q-switched Nd:YAG laser for LASIK application based on three stages harmonic generation procedures. A novel crystal housing was specifically designed to hold the three crystals with each crystal has independent, precise angular adjustment structure and automatic tuning control. The crystal temperature is well maintained at ~130°C to improve harmonic generation stability and crystal operation lifetime. An output pulse energy 35mJ is obtained at 213nm, corresponding to total conversion efficiency ~10% from 1064nm pump laser. In system verification tests, the 213nm output power drops less than 5% after 5 millions pulse shots and no significant damage appears in the crystals.

  11. Comparison of a novel high-power blue diode laser (λ=442 nm) with Ho:YAG (λ=2100 nm), Tm fiber (λ=1940 nm), and KTP (λ=532 nm) lasers for soft tissue ablation

    Science.gov (United States)

    Vinnichenko, Victoriya; Kovalenko, Anastasiya; Arkhipova, Valeriya; Yaroslavsky, Ilya; Altshuler, Gregory; Gapontsev, Valentin

    2018-02-01

    Three lasers were directly compared, including the Ho:YAG laser (λ = 2100 nm), Tm fiber laser (λ = 1940 nm) operating in 3 different modes (CW, regular pulse, and super pulse), and blue diode laser (λ = 442 nm) for vaporization and coagulation efficiency for treating blood-rich soft tissues, ex vivo, in a porcine kidney model at quasi-contact cutting in water. In addition, experimental results were compared with published data on performance of KTP laser (λ = 532 nm) at similar experimental settings (Power = 60 W and cutting speed = 2 mm/s). Tm fiber laser in pulsed mode and blue laser produced highest vaporization rates of 3.7 and 3.4 mm3/s, respectively. Tm fiber laser (in both CW and pulsed modes) also produced the largest coagulation zone among the laser sources tested. A carbonization zone was observed for Tm fiber laser in CW and pulsed modes, as well as for the blue diode laser. Tm fiber laser in super-pulse mode and Ho:YAG laser both resulted in irregular coagulation zones without carbonization. Comparison with known data for KTP laser revealed that tissue effects of the blue laser are similar to that of the KTP laser. These results suggest that the combination of the two lasers (Tm fiber and blue diode) in one system may achieve high cutting efficiency and optimal coagulation for hemostasis during surgical treatment. Ex vivo testing of the combined system revealed feasibility of this approach. The combination of the CW Tm fiber laser (120W) and the blue diode laser (60W) emitting through a combination tip were compared with CW 120 W Tm fiber laser alone and 120 W Ho:YAG laser. Vaporization rates measured 34, 28, and 6 mm3/s, and coagulation zones measured 0.6, 1.3, and 1.7 mm, respectively. A carbonization zone was only observed with CW Tm fiber laser. The vaporization rate of combined CW Tm fiber laser / blue diode laser was comparable to published data for KTP laser for equivalent total power. Thus, high-power blue diode laser, Tm fiber laser, and

  12. PM Raman fiber laser at 1679 nm

    DEFF Research Database (Denmark)

    Svane, Ask Sebastian; Rottwitt, Karsten

    2012-01-01

    We demonstrate a PM Raman fiber laser emitting light at 1679 nm. The laser has an slope efficiency of 67 % and an output power of more than 275mWwith a 27 pm linewidth.......We demonstrate a PM Raman fiber laser emitting light at 1679 nm. The laser has an slope efficiency of 67 % and an output power of more than 275mWwith a 27 pm linewidth....

  13. 100-nm gate lithography for double-gate transistors

    Science.gov (United States)

    Krasnoperova, Azalia A.; Zhang, Ying; Babich, Inna V.; Treichler, John; Yoon, Jung H.; Guarini, Kathryn; Solomon, Paul M.

    2001-09-01

    The double gate field effect transistor (FET) is an exploratory device that promises certain performance advantages compared to traditional CMOS FETs. It can be scaled down further than the traditional devices because of the greater electrostatic control by the gates on the channel (about twice as short a channel length for the same gate oxide thickness), has steeper sub-threshold slope and about double the current for the same width. This paper presents lithographic results for double gate FET's developed at IBM's T. J. Watson Research Center. The device is built on bonded wafers with top and bottom gates self-aligned to each other. The channel is sandwiched between the top and bottom polysilicon gates and the gate length is defined using DUV lithography. An alternating phase shift mask was used to pattern gates with critical dimensions of 75 nm, 100 nm and 125 nm in photoresist. 50 nm gates in photoresist have also been patterned by 20% over-exposure of nominal 100 nm lines. No trim mask was needed because of a specific way the device was laid out. UV110 photoresist from Shipley on AR-3 antireflective layer were used. Process windows, developed and etched patterns are presented.

  14. Solar UV Variations During the Decline of Cycle 23

    Science.gov (United States)

    DeLand, Matthew, T.; Cebula, Richard P.

    2011-01-01

    Characterization of temporal and spectral variations in solar ultraviolet irradiance over a solar cycle is essential for understanding the forcing of Earth's atmosphere and climate. Satellite measurements of solar UV variability for solar cycles 21, 22, and 23 show consistent solar cycle irradiance changes at key wavelengths (e.g. 205 nm, 250 nm) within instrumental uncertainties. All historical data sets also show the same relative spectral dependence for both short-term (rotational) and long-term (solar cycle) variations. Empirical solar irradiance models also produce long-term solar UV variations that agree well with observational data. Recent UV irradiance data from the Solar Radiation and Climate Experiment (SORCE) Spectral Irradiance Monitor (SIM) and Solar Stellar Irradiance Comparison Experiment (SOLSTICE) instruments covering the declining phase of Cycle 23 present a different picture oflong-term solar variations from previous results. Time series of SIM and SOLSTICE spectral irradiance data between 2003 and 2007 show solar variations that greatly exceed both previous measurements and predicted irradiance changes over this period, and the spectral dependence of the SIM and SOLSTICE variations during these years do not show features expected from solar physics theory. The use of SORCE irradiance variations in atmospheric models yields substantially different middle atmosphere ozone responses in both magnitude and vertical structure. However, short-term solar variability derived from SIM and SOLSTICE UV irradiance data is consistent with concurrent solar UV measurements from other instruments, as well as previous results, suggesting no change in solar physics. Our analysis of short-term solar variability is much less sensitive to residual instrument response changes than the observations of long-term variations. The SORCE long-term UV results can be explained by under-correction of instrument response changes during the first few years of measurements

  15. Organic antireflective coatings for 193-nm lithography

    Science.gov (United States)

    Trefonas, Peter, III; Blacksmith, Robert F.; Szmanda, Charles R.; Kavanagh, Robert J.; Adams, Timothy G.; Taylor, Gary N.; Coley, Suzanne; Pohlers, Gerd

    1999-06-01

    Organic anti-reflective coatings (ARCs) continue to play an important role in semiconductor manufacturing. These materials provide a convenient means of greatly reducing the resist photospeed swing and reflective notching. In this paper, we describe a novel class of ARC materials optimized for lithographic applications using 193 nm exposure tools. These ARCs are based upon polymers containing hydroxyl-alkyl methacrylate monomers for crosslinkable sites, styrene for a chromophore at 193 nm, and additional alkyl-methacrylate monomers as property modifiers. A glycouril crosslinker and a thermally-activated acidic catalyst provide a route to forming an impervious crosslinked film activate data high bake temperatures. ARC compositions can be adjusted to optimize the film's real and imaginary refractive indices. Selection of optimal target indices for 193 nm lithographic processing through simulations is described. Potential chromophores for 193 nm were explored using ZNDO modeling. We show how these theoretical studies were combined with material selection criteria to yield a versatile organic anti-reflectant film, Shipley 193 G0 ARC. Lithographic process data indicates the materials is capable of supporting high resolution patterning, with the line features displaying a sharp resist/ARC interface with low line edge roughness. The resist Eo swing is successfully reduced from 43 percent to 6 percent.

  16. Intra-cavity upconversion to 631 nm of images illuminated by an eye-safe ASE source at 1550 nm.

    Science.gov (United States)

    Torregrosa, A J; Maestre, H; Capmany, J

    2015-11-15

    We report an image wavelength upconversion system. The system mixes an incoming image at around 1550 nm (eye-safe region) illuminated by an amplified spontaneous emission (ASE) fiber source with a Gaussian beam at 1064 nm generated in a continuous-wave diode-pumped Nd(3+):GdVO(4) laser. Mixing takes place in a periodically poled lithium niobate (PPLN) crystal placed intra-cavity. The upconverted image obtained by sum-frequency mixing falls around the 631 nm red spectral region, well within the spectral response of standard silicon focal plane array bi-dimensional sensors, commonly used in charge-coupled device (CCD) or complementary metal-oxide-semiconductor (CMOS) video cameras, and of most image intensifiers. The use of ASE illumination benefits from a noticeable increase in the field of view (FOV) that can be upconverted with regard to using coherent laser illumination. The upconverted power allows us to capture real-time video in a standard nonintensified CCD camera.

  17. Four-Terminal All-Perovskite Tandem Solar Cells Achieving Power Conversion Efficiencies Exceeding 23%

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Kai [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Zhao, Dewei [University of Toledo; Wang, Changlei [University of Toledo; Wuhan University; Song, Zhaoning [University of Toledo; Yu, Yue [University of Toledo; Chen, Cong [University of Toledo; Zhao, Xingzhong [Wuhan University; Yan, Yanfa [University of Toledo

    2018-02-09

    We report on fabrication of 4-terminal all-perovskite tandem solar cells with power conversion efficiencies exceeding 23% by mechanically stacking semitransparent 1.75 eV wide-bandgap FA0.8Cs0.2Pb(I0.7Br0.3)3 perovskite top cells with 1.25 eV low-bandgap (FASnI3)0.6(MAPbI3)0.4 bottom cells. The top cells use MoOx/ITO transparent electrodes and achieve transmittance up to 70% beyond 700 nm.

  18. Development of β Type Ti23Mo-45S5 Bioglass Nanocomposites for Dental Applications

    Directory of Open Access Journals (Sweden)

    Karolina Jurczyk

    2015-11-01

    Full Text Available Titanium β-type alloys attract attention as biomaterials for dental applications. The aim of this work was the synthesis of nanostructured β type Ti23Mo-x wt % 45S5 Bioglass (x = 0, 3 and 10 composites by mechanical alloying and powder metallurgy methods and their characterization. The crystallization of the amorphous material upon annealing led to the formation of a nanostructured β type Ti23Mo alloy with a grain size of approximately 40 nm. With the increase of the 45S5 Bioglass contents in Ti23Mo, nanocomposite increase of the α-phase is noticeable. The electrochemical treatment in phosphoric acid electrolyte resulted in a porous surface, followed by bioactive ceramic Ca-P deposition. Corrosion resistance potentiodynamic testing in Ringer solution at 37 °C showed a positive effect of porosity and Ca-P deposition on nanostructured Ti23Mo 3 wt % 45S5 Bioglass nanocomposite. The contact angles of glycerol on the nanostructured Ti23Mo alloy were determined and show visible decrease for bulk Ti23Mo 3 wt % 45S5 Bioglass and etched Ti23Mo 3 wt % 45S5 Bioglass nanocomposites. In vitro tests culture of normal human osteoblast cells showed very good cell proliferation, colonization, and multilayering. The present study demonstrated that porous Ti23Mo 3 wt % 45S5 Bioglass nanocomposite is a promising biomaterial for bone tissue engineering.

  19. Sulphur abundances in halo giants from the [S ı] line at 1082 nm and the [S ı] triplet around 1045 nm

    DEFF Research Database (Denmark)

    Jönsson, H.; Ryde, N.; Nissen, Poul Erik

    2011-01-01

    to clarify this situation by measuring the sulphur abundance in a sample of halo giants using two diagnostics: the S i triplet around 1045 nm and the [S i] line at 1082 nm. The latter of the two is not believed to be sensitive to non-LTE effects. We can thereby minimize the uncertainties in the diagnostic...... used and estimate the usefulness of the triplet for the sulphur determination in halo K giants. We will also be able to compare our sulphur abundance differences from the two diagnostics with the expected non-LTE effects in the 1045 nm triplet previously calculated by others. Methods. High...... diagnostics using tailored 1D model atmospheres and relying on non-LTE corrections from the litterature. Effects of convective inhomogeneities in the stellar atmospheres are investigated. Results. The sulphur abundances derived from both the [S i] line and the non-LTE corrected 1045 nm triplet favor a flat...

  20. Laser ablation of ceramic Al2O3 at 193 nm and 248 nm: The importance of single-photon ionization processes

    Science.gov (United States)

    Peláez, R. J.; Afonso, C. N.; Bator, M.; Lippert, T.

    2013-06-01

    The aim of this work is to demonstrate that single-photon photoionization processes make a significant difference in the expansion and temperature of the plasma produced by laser ablation of ceramic Al2O3 in vacuum as well as to show their consequences in the kinetic energy distribution of the species that eventually will impact on the film properties produced by pulsed laser deposition. This work compares results obtained by mass spectrometry and optical spectroscopy on the composition and features of the plasma produced by laser ablation at 193 nm and 248 nm, i.e., photon energies that are, respectively, above and below the ionization potential of Al, and for fluences between threshold for visible plasma and up to ≈2 times higher. The results show that the ionic composition and excitation of the plasma as well as the ion kinetic energies are much higher at 193 nm than at 248 nm and, in the latter case, the population of excited ions is even negligible. The comparison of Maxwell-Boltzmann temperature, electron temperatures, and densities of the plasmas produced with the two laser wavelengths suggests that the expansion of the plasma produced at 248 nm is dominated by a single population. Instead, the one produced at 193 nm is consistent with the existence of two populations of cold and hot species, the latter associated to Al+ ions that travel at the forefront and produced by single photon ionization as well as Al neutrals and double ionized ions produced by electron-ion impact. The results also show that the most energetic Al neutrals in the plasma produced at the two studied wavelengths are in the ground state.

  1. Single-treatment skin tightening by radiofrequency and long-pulsed, 1064-nm Nd: YAG laser compared.

    Science.gov (United States)

    Key, Douglas J

    2007-02-01

    To compare single-treatment facial skin tightening achieved with the current radiofrequency (RF) protocol with single-treatment tightening achieved with the long-pulsed, 1064-nm Nd:YAG laser. A total of 12 patients were treated with RF energy on one side of the face and laser energy on the other. Results were evaluated on a numerical scale (0-12 with 12 = greatest enhancement) from pre- and posttreatment photographs by a blinded panel. Upper face improvement (posttreatment score minus pretreatment score) was essentially the same on both sides (30.2 and 31.3% improvement for laser and RF, respectively, P=0.89). Lower face improvement was greater in the laser-treated side (35.7 and 23.8% improvement for laser and RF, respectively), but the difference was not significant (P=0.074). Overall face improvement was significantly greater on the laser-treated side (47.5 and 29.8% improvement for laser and RF, respectively, P=0.028). A single high-fluence treatment with the long-pulse 1064-nm Nd:YAG laser may improve skin laxity more than a single treatment with the RF device. Further controlled split-face or very large non-self controlled studies are needed to conclusively determine the relative efficacies of the two technologies. (c) 2007 Wiley-Liss, Inc.

  2. Tapered diode laser pumped 946 nm Nd:YAG laser

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2009-01-01

    We successfully implemented a 946 nm Nd:YAG laser based on a 808 nm tapered diode pump laser. The tapered diode is developed at the Ferdinand-Braun-Institute fur Hochstfrequenztechnik in Germany. Figure 2 shows the experimental setup and results of each pump source coupled into a 1.5 mm crystal...... laser, we show that tapered diode laser pumping potentially increase the power of 946 nm lasers by a factor of two and reduce the threshold by a factor of three....

  3. Choroidal thinning in diabetes type 1 detected by 3-dimensional 1060 nm optical coherence tomography.

    Science.gov (United States)

    Esmaeelpour, Marieh; Brunner, Simon; Ansari-Shahrezaei, Siamak; Shahrezaei, Siamak Ansari; Nemetz, Susanne; Povazay, Boris; Kajic, Vedran; Drexler, Wolfgang; Binder, Susanne

    2012-10-03

    To map choroidal (ChT) and retinal thickness (RT) in patients with diabetes type 1 with and without maculopathy and retinopathy in order to compare them with healthy subjects using high speed 3-dimensional (3D) 1060 nm optical coherence tomography (OCT). Thirty-three eyes from 33 diabetes type 1 subjects (23-57 years, 15 male) divided into groups of without pathology (NDR) and with pathology (DR; including microaneurysms, exudates, clinically significant macular-oedema and proliferative retinopathy) were compared with 20 healthy axial eye length and age-matched subjects (24-57 years, 9 male), imaged by high speed (60.000 A-scans/s) 3D 1060 nm OCT performed over 36° × 36° field of view. Ocular health status, disease duration, body mass index, haemoglobin-A1c, and blood pressure (bp) measurements were recorded. Subfoveal ChT, and 2D topographic maps between retinal pigment epithelium and the choroidal/scleral-interface, were automatically generated and statistically analyzed. Subfoveal ChT (mean ± SD, μm) for healthy eyes was 388 ± 109; significantly thicker than all diabetic groups, 291 ± 64 for NDR, and 303 ± 82 for DR (ANOVA P 0.05). Compared with healthy eyes and the NDR, the averaged DR ChT-map demonstrated temporal thinning that extended superiorly and temporal-inferiorly (unpaired t-test, P 0.05). ChT is decreased in diabetes type 1, independent of the absence of pathology and of diabetic disease duration. In eyes with pathology, 3D 1060 nm OCT averaged maps showed an extension of the thinning area matching retinal lesions and suggesting its involvement on onset or progression of disease.

  4. Ultraviolet relaxation dynamics of aniline, N, N-dimethylaniline and 3,5-dimethylaniline at 250 nm

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, James O. F.; Saalbach, Lisa; Crane, Stuart W. [Institute of Photonics and Quantum Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom); Paterson, Martin J. [Institute of Chemical Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom); Townsend, Dave, E-mail: D.Townsend@hw.ac.uk [Institute of Photonics and Quantum Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom); Institute of Chemical Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom)

    2015-03-21

    Time-resolved photoelectron imaging was used to investigate the electronic relaxation dynamics of gas-phase aniline, N, N-dimethylaniline, and 3,5-dimethylaniline following ultraviolet excitation at 250 nm. Our analysis was supported by ab initio coupled-cluster calculations evaluating excited state energies and (in aniline) the evolution of a range of excited state physical properties as a function of N–H bond extension. Due to a lack of consistency between several earlier studies undertaken in aniline, the specific aim of this present work was to gain new insight into the previously proposed non-adiabatic coupling interaction between the two lowest lying singlet excited states S{sub 1}(ππ{sup ∗}) and S{sub 2}(3s/πσ{sup ∗}). The methyl-substituted systems N, N-dimethylaniline and 3,5-dimethylaniline were included in order to obtain more detailed dynamical information about the key internal molecular coordinates that drive the S{sub 1}(ππ{sup ∗})/S{sub 2}(3s/πσ{sup ∗}) coupling mechanism. Our findings suggest that in all three systems, both electronic states are directly populated during the initial excitation, with the S{sub 2}(3s/πσ{sup ∗}) state then potentially decaying via either direct dissociation along the N–X stretching coordinate (X = H or CH{sub 3}) or internal conversion to the S{sub 1}(ππ{sup ∗}) state. In aniline and N, N-dimethylaniline, both pathways most likely compete in the depletion of S{sub 2}(3s/πσ{sup ∗}) state population. However, in 3,5-dimethylaniline, only the direct dissociation mechanism appears to be active. This is rationalized in terms of changes in the relative rates of the two decay pathways upon methylation of the aromatic ring system.

  5. Comparative mutagenesis and interaction between near-ultraviolet (313- to 405-nm) and far-ultraviolet (254-nm) radiation in Escherichia coli strains with differing repair capabilities

    International Nuclear Information System (INIS)

    Turner, M.A.; Webb, R.B.

    1981-01-01

    Comparative mutagenesis and possible synergistic interaction between broad-spectrum (313- to 405-nm) near-ultraviolet (black light bulb [BLB]) radiation and 254-nm radiation were studied in Escherichia coli strains WP2 (wild type), WP2s (uvrA), WP10 (recA), WP6 (polA), WP6s (polA uvrA), WP100 (uvrA recA), and WP5 (lexA). With BLB radiation, strains WP2s and WP6s demonstrated a high level of mutagenesis, whereas strains WP2, WP5, WP6, WP10, and WP100 did not demonstrate significant mutagenesis. In contrast, 254-nm radiation was mutagenic in strains WP2, WP2s, WP6, and WP6s, but strains WP5, WP10, and WP100 were not significantly mutated. The absence of mutagenesis by BLB radiation in lexA and recA strains WP10, WP5, and WP100 suggests that lex + rec + repair may play a major role in mutagenesis by both BLB and 254-nm radiation. The hypothesis that BLB radiation selectively inhibits rec + lex + repair was tested by sequential BLB-254 nm radiation. With strain WP2, a fluence of 30 J/m 2 at 254 nm induced trp + revertants at a frequency of 15 x 10 -6 . However, when 10 5 J/m 2 or more BLB radiation preceded the 254-nm exposure, no trp + revertants could be detected. A similar inhibition of 254-nm mutagenesis was observed with strain WP6 (polA). However, strains WP2s (uvrA) and WP6s (polA uvrA) showed enhanced 254-nm mutagenesis when a prior exposure to BLB radiation was given

  6. Combined fractional resurfacing (10600 nm/1540 nm): Tridimensional imaging evaluation of a new device for skin rejuvenation.

    Science.gov (United States)

    Mezzana, Paolo; Valeriani, Maurizio; Valeriani, Roberto

    2016-11-01

    In this study were described the results, by tridimensional imaging evaluation, of the new "Combined Fractional Resurfacing" technique with the first fractional laser that overtakes the limits of traditional ablative, nonablative fractional resurfacing by combining CO 2 ablative and GaAs nonablative lasers. These two wavelengths can work separately or in a mixed modality to give the best treatment choice to all the patients. In this study, it is demonstrated that the simultaneous combination of the CO 2 wavelength (10600 nm) and GaAs wavelength (1540 nm) reduced the downtime, reduced pain during the treatment, and produced better results on fine wrinkles reduction and almost the same results on pigmentation as seen with 3D analysis by Antera (Miravex).

  7. Diode-pumped continuous-wave eye-safe Nd:YAG laser at 1415 nm.

    Science.gov (United States)

    Lee, Hee Chul; Byeon, Sung Ug; Lukashev, Alexei

    2012-04-01

    We describe the output performance of the 1415 nm emission in Nd:YAG in a plane-concave cavity under traditional pumping into the 4F5/2 level (808 nm) and direct in-band pumping into the 4F3/2 level (885 nm). An end-pumped Nd:YAG laser yielded maximum cw output power of 6.3 W and 4.2 W at 885 nm and 808 nm laser diode (LD) pumping, respectively. To the best of our knowledge, this is the highest output power of a LD-pumped 1415 nm laser.

  8. Investigation of a Pulsed 1550 nm Fiber Laser System (Briefing Charts)

    Science.gov (United States)

    2016-02-14

    Pump dump and splice Pump dump and splice MFA 976 nm 15 W TFB TFB Pump dump and splice Waveform shaping Delay Power meter...filter 976 nm 7.6 W TFB WDM Pump dump and splice Pump dump and splice MFA 976 nm 15 W TFB TFB Pump dump and splice Waveform shaping...Multimode fiber to OSA or photodiode EOM EOM ASE filter ASE filter 976 nm 7.6 W TFB

  9. Design of an 1800nm Raman amplifier

    DEFF Research Database (Denmark)

    Svane, Ask Sebastian; Rottwitt, Karsten

    2013-01-01

    We present the experimental results for a Raman amplifier that operates at 1810 nm and is pumped by a Raman fiber laser at 1680 nm. Both the pump laser and the Raman amplifier is polarization maintaining. A challenge when scaling Raman amplifiers to longer wavelengths is the increase...... in transmission loss, but also the reduction in the Raman gain coefficient as the amplifier wavelength is increased. Both polarization components of the Raman gain is characterized, initially for linearly co-polarized signal and pump, subsequently linearly polarized orthogonal signal and pump. The noise...

  10. Treatment of tattoos with a 755-nm Q-switched alexandrite laser and novel 1064 nm and 532 nm Nd:YAG laser handpieces pumped by the alexandrite treatment beam.

    Science.gov (United States)

    Bernstein, Eric F; Bhawalkar, Jay; Clifford, Joan; Hsia, James

    2010-11-01

    Multi-colored and even black tattoos often require more than one wavelength to remove the target pigment. The authors report here a novel alexandrite laser with two Nd:YAG laser handpieces pumped by the alexandrite treatment beam enabling the delivery of three wavelengths from a single device. To describe and evaluate the effectiveness of a novel Q-switched laser-pumped laser for treating tattoos. Twenty tattoos in 14 subjects were treated at four-week intervals using a combination of available wavelengths (532, 755 and 1064 nm) as determined by the treating physician. Digital cross-polarized photographs were taken before treatment and two months following the fourth and final treatment. Photographs were evaluated by three physician observers blinded as to the treatment condition and rated for clearance by the following scale: 1 = > 95 percent, 2 = 76-95 percent, 3 = 51-75 percent, 4 = 26-50 percent and 5 = 0-25 percent clearance. The average clearance score was 3.1, in the 51-75 percent range, two months following four treatments. No scarring, hyper- or hypopigmentation was noted on post-treatment photographs or by the treating physician. The alexandrite and alexandrite-pumped 532 nm and 1064 nm Q-switched lasers are effective for removing decorative tattoos, and represents the first commercial laser with laser-pumped, laser handpieces.

  11. First demonstration of InGaP/InAlGaP based 608nm orange laser and 583nm yellow superluminescent diode

    KAUST Repository

    Majid, Mohammed Abdul

    2015-11-12

    We report on the first demonstration of InGaP/InAlGaP based orange semiconductor laser (OSL) and yellow superluminescent diode (YSLD) emitting at a wavelength of 608nm and 583nm respectively. The total output power of YSLD is ∼4.5mW which is the highest ever reported power on this material system at room-temperature.

  12. Photorefractive effect at 775 nm in doped lithium niobate crystals

    Energy Technology Data Exchange (ETDEWEB)

    Nava, G.; Minzioni, P.; Cristiani, I.; Degiorgio, V. [Department of Electrical, Computer, and Biomedical Engineering, and CNISM, University of Pavia, 27100 Pavia (Italy); Argiolas, N.; Bazzan, M.; Ciampolillo, M. V.; Pozza, G.; Sada, C. [Physics and Astronomy Departement, University of Padova, 35131 Padova (Italy)

    2013-07-15

    The photorefractive effect induced by 775-nm laser light on doped lithium niobate crystals is investigated by the direct observation in the far field of the transmitted-beam distortion as a function of time. Measurements performed at various Zr-doping concentrations and different light intensities show that the 775-nm light beam induces a steady-state photorefractive effect comparable to that of 532-nm light, but the observed build-up time of the photovoltaic field is longer by three-orders of magnitude. The 775-nm photorefractivity of lithium niobate crystals doped with 3 mol. % ZrO{sub 2} or with 5.5 mol. % MgO is found to be negligible.

  13. Low-noise low-jitter 32-pixels CMOS single-photon avalanche diodes array for single-photon counting from 300 nm to 900 nm

    Energy Technology Data Exchange (ETDEWEB)

    Scarcella, Carmelo; Tosi, Alberto, E-mail: alberto.tosi@polimi.it; Villa, Federica; Tisa, Simone; Zappa, Franco [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo da Vinci 32, I-20133 Milano (Italy)

    2013-12-15

    We developed a single-photon counting multichannel detection system, based on a monolithic linear array of 32 CMOS SPADs (Complementary Metal-Oxide-Semiconductor Single-Photon Avalanche Diodes). All channels achieve a timing resolution of 100 ps (full-width at half maximum) and a photon detection efficiency of 50% at 400 nm. Dark count rate is very low even at room temperature, being about 125 counts/s for 50 μm active area diameter SPADs. Detection performance and microelectronic compactness of this CMOS SPAD array make it the best candidate for ultra-compact time-resolved spectrometers with single-photon sensitivity from 300 nm to 900 nm.

  14. Removing foxing stains from old paper at 157 nm

    International Nuclear Information System (INIS)

    Sarantopoulou, E.; Samardzija, Z.; Kobe, S.; Kollia, Z.; Cefalas, A.C.

    2003-01-01

    Using a molecular fluorine laser at 157 nm foxing stains were removed successfully from a 16th century old paper. Laser cleaning of stains and foxing from old paper manuscripts is far more effective at 157 nm in comparison to different wavelengths without leaving any yellowish after-effect on the paper. This is because at 157 nm illumination of old paper, complete bond breaking of all the organic molecules of the paper is taking place. Mass spectroscopy at 157 nm and for moderate laser intensities up to 1 mJ/cm 2 of old paper suffering from foxing indicate organic matter disintegration to small photofragments atomic, diatomic or triatomic, which are flying apart with supersonic speed. In addition high spatial resolution energy dispersive X-ray system (EDXS) analysis over the effected areas indicate the presence of iron, suggesting that biological activity is taking place preferentially in paper areas containing iron

  15. Stimulation of DNA synthesis by 340nm/ 351nm UV laser irradiation

    International Nuclear Information System (INIS)

    Meldrum, R.A.; Wharton, C.W.

    1991-01-01

    During preliminary experiments designed to test the feasibility of using a 'caged' DNA break trapping agent, the authors observed a stimulation of incorporation of 3 H-thymidine into DNA when cells were irradiated with low doses (100-1000J/m 2 ) of 351nm UV laser irradiation. This wavelength is used to photolyse 'caged' dideoxynucleotides in our fast time course measurements of DNA repair in mammalian cells. The dose at which this stimulation was observed is well below that at which measurable damage is detected. (author)

  16. Large-scale lithography for sub-500nm features

    International Nuclear Information System (INIS)

    Pelzer, R L; Steininger, T; Belier, Benoit; Julie, Gwenaelle

    2006-01-01

    The interest in micro- and nanotechnologies has grown rapidly in the last years. The applications are versatile and different techniques found its way into several research domains as optics, electronics, magnetism, fluidics, etc. In all of these fields integration of more and more functions on steadily decreasing device dimensions lead to an increase in structural density and feature size. Expensive and slow processes utilizing projection steppers or e-beam direct writer equipment are used to fabricate nm features today. A high throughput and cost effective method adapted on a standard mask aligner will be demonstrated, making features of below 300nm available on wafer-level. We will demonstrate results of 4 different resists exposed on a DUV proximity aligner and plasma etched for optical and biological applications in the sub-300nm range

  17. Large-scale lithography for sub-500nm features

    Energy Technology Data Exchange (ETDEWEB)

    Pelzer, R L [Technology group, EV Group, DI Erich Thallner Str. 1, A-4780 Schaerding (Austria); Steininger, T [Technology group, EV Group, DI Erich Thallner Str. 1, A-4780 Schaerding (Austria); Belier, Benoit [CNRS, Institut d' Electronique Fondamentale, Universite Paris-Sud Bat 220, F- 91405 Orsay Cedex (France); Julie, Gwenaelle [CNRS, Institut d' Electronique Fondamentale, Universite Paris-Sud Bat 220, F- 91405 Orsay Cedex (France)

    2006-04-01

    The interest in micro- and nanotechnologies has grown rapidly in the last years. The applications are versatile and different techniques found its way into several research domains as optics, electronics, magnetism, fluidics, etc. In all of these fields integration of more and more functions on steadily decreasing device dimensions lead to an increase in structural density and feature size. Expensive and slow processes utilizing projection steppers or e-beam direct writer equipment are used to fabricate nm features today. A high throughput and cost effective method adapted on a standard mask aligner will be demonstrated, making features of below 300nm available on wafer-level. We will demonstrate results of 4 different resists exposed on a DUV proximity aligner and plasma etched for optical and biological applications in the sub-300nm range.

  18. Metastable Magnesium fluorescence spectroscopy using a frequency-stabilized 517 nm laser

    DEFF Research Database (Denmark)

    He, Ming; Jensen, Brian B; Therkildsen, Kasper T

    2009-01-01

    We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we obta...... obtained more than 40 mW of 517 nm output power by single pass frequency doubling. In addition, fluorescence spectroscopy of metastable magnesium atoms could be used to stabilize the 517 nm laser to an absolute frequency within 1 MHz.......We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we...

  19. Irrigation management and phosphorus addition alter the abundance of carbon dioxide-fixing autotrophs in phosphorus-limited paddy soil.

    Science.gov (United States)

    Wu, Xiaohong; Ge, Tida; Yan, Wende; Zhou, Juan; Wei, Xiaomeng; Chen, Liang; Chen, Xiangbi; Nannipieri, Paolo; Wu, Jinshui

    2017-12-01

    In this study, we assessed the interactive effects of phosphorus (P) application and irrigation methods on the abundances of marker genes (cbbL, cbbM, accA and aclB) of CO2-fixing autotrophs. We conducted rice-microcosm experiments using a P-limited paddy soil, with and without the addition of P fertiliser (P-treated-pot (P) versus control pot (CK)), and using two irrigation methods, namely alternate wetting and drying (AWD) and continuous flooding (CF). The abundances of bacterial 16S rRNA, archaeal 16S rRNA, cbbL, cbbM, accA and aclB genes in the rhizosphere soil (RS) and bulk soil (BS) were quantified. The application of P significantly altered the soil properties and stimulated the abundances of Bacteria, Archaea and CO2-fixation genes under CF treatment, but negatively influenced the abundances of Bacteria and marker genes of CO2-fixing autotrophs in BS soils under AWD treatment. The response of CO2-fixing autotrophs to P fertiliser depended on the irrigation management method. The redundancy analysis revealed that 54% of the variation in the functional marker gene abundances could be explained by the irrigation method, P fertiliser and the Olsen-P content; however, the rhizosphere effect did not have any significant influence. P fertiliser application under CF was more beneficial in improving the abundance of CO2-fixing autotrophs compared to the AWD treatment; thus, it is an ideal irrigation management method to increase soil carbon fixation. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Application of rapid read-out cleaning indicators for improved process control in hospital sterile services departments.

    Science.gov (United States)

    Nugent, P G; Modi, T; McLeod, N; Bock, L J; Smith, C; Poolman, T M; Warburton, R; Meighan, P; Wells, P; Sutton, J M

    2013-05-01

    Heightened awareness of the importance of cleaning has led to an emphasis on automated systems for the decontamination of re-usable medical devices. The authors have previously described an enzymatic indicator system, based on thermostable adenylate kinases (tAK), for quantitative monitoring of automated cleaning processes within hospital sterile services departments (SSDs). To evaluate tAK indicators for routine process monitoring across a range of SSDs with different cleaning chemistries and different automated washer disinfectors (AWDs). tAK indicator devices and alternative industry test indicators were included in five independent cleaning cycles in each of eight different AWDs. Residual tAK post wash was determined by a coupled luciferase assay using a modified hygiene monitoring system. In all cases, with the exception of a single test, the alternative indicators showed that cleaning had been adequate. They were not able to discriminate between the performance of different processes. In contrast, the tAK indicators were able to resolve differences in the performance of processes across the different SSDs. Where the tAK indicators identified cleaning to the limits of detection of the assay, this demonstrated a log10 enzyme removal factor of >5.69. The results suggest that tAK indicators are suitable for providing improved process control for automated cleaning processes, being able to distinguish between wash performance in different hospital settings and between individual process runs. This technology is believed to be a useful addition to routine AWD performance qualification when used as a daily or weekly test. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  1. [Comparative investigation of underwater-LIBS using 532 and 1 064 nm lasers].

    Science.gov (United States)

    Song, Jiao-Jian; Tian, Ye; Lu, Yuan; Li, Ying; Zheng, Rong-Er

    2014-11-01

    With the hope of applying laser induced breakdown spectroscopy (LIBS) to the ocean applications, the laser energy at 532 and 1 064 nm wavelength with 3 and 40 mj respectively was used, which was near their breakdown threshold. Extensive experimental investigations of LIBS from CaCl2 water solution were carried out in this paper using different laser wavelengths of 532 and 1 064 nm. The obtained results show that compared with the 532 nm laser, the 1 064 nm laser can induce the plasma in water with higher emission intensity and longer lifetime, while the reproducibility of LIBS signal under 1 064 nm laser is poorer. On the other hand, due to the different attenuation ratios of 532 and 1 064 nm laser energies in water, the LIBS signal of 1 064 nm laser decreases a lot within the transmission distance range 2-5 cm, while LIBS signal of 532 nm remains the same, because that the wavelength of 532 nm lies in the "transmission window" of the water solution. This study will provide valuable design considerations for the development of LIBS-sea system in near future.

  2. Soft X-Ray Magneto-optical Faraday Effect around Ni M2,3 Edges

    International Nuclear Information System (INIS)

    Kai, Chen; Ming-Qi, Cui; Fen, Yan; Li-Juan, Sun; Lei, Zheng; Chen-Yan, Ma; Shi-Bo, Xi; Yi-Dong, Zhao; Jia, Zhao

    2008-01-01

    We present magneto-optical (MO) Faraday spectra measured around the M 2,3 edges (60–70eV) of Ni films at the Beijing Synchrotron Radiation Facility (BSRF). A polarization analysis of the final state of the transmitted radiation from the Ni film is employed to determine the Faraday rotation at the edges. The MO effect becomes resonantly enhanced at the M 2,3 edges, and accordingly large values for the rotation angle β of 1.85 ± 0.19° for this ferromagnetic Ni film with thickness of 31 nm are measured. Without the magnetic field, the azimuthal angles do not shift; with parallel and antiparallel magnetic field the rotation angles shift in the opposite way and they are symmetrical. The uncertainty of Faraday rotation angles mainly comes from the data fitting and the state change of the beamline when the angles are measured

  3. Safety and Efficacy of a 1550nm/1927nm Dual Wavelength Laser for the Treatment of Photodamaged Skin.

    Science.gov (United States)

    Narurkar, Vic A; Alster, Tina S; Bernstein, Eric F; Lin, Tina J; Loncaric, Anya

    2018-01-01

    BACKGROUND: Fractional photothermolysis (FP) is a popular treatment option for photodamaged skin and addresses shortcomings of ablative skin resurfacing and nonablative dermal remodeling. Previous studies have demonstrated that FP using the 1550nm wavelength has led to improvement of ultrastructural changes and clinical effects associated with photodamaged skin in the deeper dermal structures, while treatment with the 1927nm wavelength has shown clinical effects in the superficial dermis. Both wavelengths produce precise microscopic treatment zones (MTZs) in the skin. The two wavelengths used in combination may optimize the delivery of fractional nonablative resurfacing intended for dermal and epidermal coagulation of photodamage skin. OBJECTIVES: To evaluate the safety and efficacy of a 1550/1927 Laser System (Fraxel Dual, Solta), using both 1550nm and 1927nm wavelengths in combination for treatment of facial and non-facial photodamage. METHODS: Prospective, multi-center, post-market study in subjects with clinically identifiable photodamage (N=35) (Fitzpatrick skin types I-IV). Both 1550nm and 1927nm wavelengths were used at each treatment visit. Investigator assessment of the affected area(s) occurred at one week, one month and 3 months after a series of up to four treatments. Severity of adverse events (AEs) were assessed using a 4-point scale (where 0=none and 3=marked). Assessments included erythema, edema, hyperkeratosis, hyper- and hypo-pigmentation, scarring, itchiness, dryness, and flaking. Severity of photoaging, fine and coarse wrinkling, mottled hyperpigmentation, sallowness, and tactile roughness at baseline was assessed using the same scale. Investigators and subjects assessed overall appearance of photodamage and pigmentation based on a 5-point quartile improvement scale at all follow-up visits (where 0=no improvement and 4=very significant improvement [76%-100%]). RESULTS: There was a positive treatment effect at all study visits, with moderate

  4. Fused Heterocyclic Compounds as Potent Indoleamine-2,3-dioxygenase 1 Inhibitors.

    Science.gov (United States)

    Panda, Subhankar; Roy, Ashalata; Deka, Suman Jyoti; Trivedi, Vishal; Manna, Debasis

    2016-12-08

    Uncontrolled metabolism of l-tryptophan (l-Trp) in the immune system has been recognized as a critical cellular process in immune tolerance. Indoleamine 2,3-dioxygenase 1 (IDO1) enzyme plays an important role in the metabolism of a local l-Trp through the kynurenine pathway in the immune systems. In this regard, IDO1 has emerged as a therapeutic target for the treatment of diseases that are associated with immune suppression like chronic infections, cancer, and others. In this study, we synthesized a series of pyridopyrimidine, pyrazolopyranopyrimidine, and dipyrazolopyran derivatives. Further lead optimizations directed to the identification of potent compounds, 4j and 4l (IC 50 = 260 and 151 nM, respectively). These compounds also exhibited IDO1 inhibitory activities in the low nanomolar range in MDA-MB-231 cells with very low cytotoxicity. Stronger selectivity for the IDO1 enzyme (>300-fold) over tryptophan 2,3-dioxygenase (TDO) enzyme was also observed for these compounds. Hence, these fused heterocyclic compounds are attractive candidates for the advanced study of IDO1-dependent cellular function and immunotherapeutic applications.

  5. Continuous-wave ceramic Nd:YAG laser at 1123 nm

    International Nuclear Information System (INIS)

    Zhang, S S; Wang, Q P; Zhang, X Y; Cong, Z H; Fan, S Z; Liu, Z J; Sun, W J

    2009-01-01

    Ceramic Nd:YAG (cNd:YAG) materials are employed to generate 1123-nm laser. A fiber-coupled continuous-wave (CW) 808-nm diode laser is used as the pumping source. With an incident diode power of 26.1 W, a CW output power of up to 10.8 W is obtained with a 10-mm-long ceramic Nd:YAG rod (1.0 at.%-Nd-doped). The conversion efficiency from diode power to 1123-nm laser power is 41.4%. The laser performance of another 10-mm-long cNd:YAG rod with a Nd-doping concentration of 0.6 at.% is studied as a comparison

  6. High-power and highly reliable 638-nm band BA-LD for CW operation

    Science.gov (United States)

    Nishida, Takehiro; Kuramoto, Kyosuke; Abe, Shinji; Kusunoki, Masatsugu; Miyashita, Motoharu; Yagi, Tetsuya

    2018-02-01

    High-power laser diodes (LDs) are strongly demanded as light sources of display applications. In multiple spatial light modulator-type projectors or liquid crystal displays, the light source LDs are operated under CW condition. The high-power 638-nm band broad-area LD for CW operation was newly developed. The LD consisted of two stripes with each width of 75 μm to reduce both an optical power density at a front facet and a threshold current. The newly improved epitaxial technology was also applied to the LD to suppress an electron overflow from an active layer. The LD showed superior output characteristics, such as output of 1.77 W at case temperature of 55 °C with wall plug efficiency (WPE) of 23%, which was improved by 40% compared with the current product. The peak WPE at 25 °C reached 40.6% under the output power of 2.37 W, CW, world highest.

  7. Prospective study of the 532 nm laser (KTP) versus diode laser 980 nm in the resection of hyperplastic lesions of the oral cavity

    Science.gov (United States)

    Bargiela-Pérez, Patricia; González-Merchán, Jorge; Díaz-Sánchez, Rosa; Serrera-Figallo, Maria-Angeles; Volland, Gerd; Joergens, Martin; Gutiérrez-Pérez, Jose-Luis

    2018-01-01

    Background The aim of this study is to evaluate the resection of hyperplastic lesions on the buccal mucosa comparing the 532nm laser (KTP), versus diode 980nm laser, considering pain, scarring, inflammation and drug consumption that occurred postoperatively with each lasers. Material and Methods A prospective study of consecutive series of 20 patients in two groups that presents hyperplastic lesions on the buccal mucosa. The choice of the KTP laser or diode 980nm laser for the surgery was made randomly. The power used was 1.5W in both groups in a continuous wave mode with a 320 μm optical fiber. Parameters of pain, scarring, inflammation and consumption of drugs were recorded by a Numerical Rating Scale and evaluated postoperatively. These recordings were made the day of the surgery, 24 hours after, 14 and 28 days after. Results Pain and inflammation was light - moderate. The consumption of paracetamol was somewhat higher in the diode 980nm laser versus the KTP laser after 24 hours, although data was not statistically significant; significant differences were found after 28 days in regards to pain (p = 0.023) and inflammation (p = 0.023), but always in the absence parameter so we find no pain in both lasers. Scarring in the two types of laser showed no differences along the visits, with not detected scar retractable. Conclusions Although there is a slight histological difference regarding the KTP laser in the oral soft tissues for clinical use, both wavelengths are very suitable for excision of oral fibroma. Key words:Laser surgery, Laser therapy, oral surgery, soft tissue, 980 nm diode laser, 532 nm KTP laser. PMID:29274158

  8. Magnetic behavior of La2/3Ca1/3MnO3 / BaTiO3 bilayers

    Science.gov (United States)

    Ordonez, John E.; Gomez, Maria E.; Lopera, Wilson; Marin, Lorena; Pardo, Jose A.; Morellon, Luis; Algarabel, Pedro; Prieto, Pedro

    2013-03-01

    We have grown ferroelectric BaTiO3(BTO) and ferromagnetic La2/3Ca1/3MnO3 (LCMO) onto (001) SrTiO3 and Nb:SrTiO3 by pulsed laser deposition (PLD) at pure oxygen atmosphere, and a substrate temperature of 820° C, seeking for a multiferroic behavior in this structure. From x-ray diffraction (XRD) we found lattice parameter aBTO=4.068 Å, and aLCMO=3.804 Å, for each individual layer. In the BTO/LCMO bilayer, (002)-Bragg peak for BTO maintain its position whereas (002) LCMO peak shift to lower Bragg angle indicating a strained LCMO film. Magnetization measurements reveal an increase in the Curie temperature from 170 K to 220 K for the bilayer when LCMO (t = 47 nm) is deposited on BTO (t=52 nm) film, while depositing the BTO (50 nm) above LCMO (48 nm) the Curie temperature remains at values close to that obtained for a LCMO single layer (~175 K), deposited under identical growth parameters This work has been supported by Instituto de Nanociencias de Aragón, Zaragoza, Spain, ``El Patrimonio Autónomo Fondo Nacional de Financiamiento para CT&I FJC'' COLCIENCIAS-CENM Contract RC 275-2011 and Research Project COLCIENCIAS-UNIVALLE.

  9. In situ growth monitoring of AlGaN/GaN distributed Bragg reflectors at 530 nm using a 633 nm laser

    Energy Technology Data Exchange (ETDEWEB)

    Wen Feng; Huang Lirong; Jiang Bo; Tong Liangzhu; Xu Wei; Liu Deming, E-mail: hlr5649@163.co [Wuhan National Laboratory for Optoelectronics, College of Opto-Electronics Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2010-09-15

    The metal-organic chemical vapor deposition (MOCVD) growth of AlGaN/GaN distributed Bragg reflectors (DBR) with a reflection peak at 530 nm was in situ monitored using 633 nm laser reflectometry. Evolutions of in situ reflected reflectivity for different kinds of AlGaN/GaN DBR were simulated by the classical transfer matrix method. Two DBR samples, which have the same parameters as the simulated structures, were grown by MOCVD. The simulated and experimental results show that it is possible to evaluate the DBR parameters from the envelope shape of the in situ reflectivity spectrum. With the help of the 633 nm laser reflectometry, a DBR light emitting diode (LED) was grown. The room temperature photoluminescence spectra show that the reflection peak of the DBR in the LED is within the design region. (semiconductor devices)

  10. Absorption spectrum of DNA for wavelengths greater than 300 nm

    International Nuclear Information System (INIS)

    Sutherland, J.C.; Griffin, K.P.

    1981-01-01

    Although DNA absorption at wavelengths greater than 300 nm is much weaker than that at shorter wavelengths, this absorption seems to be responsible for much of the biological damage caused by solar radiation of wavelengths less than 320 nm. Accurate measurement of the absorption spectrum of DNA above 300 nm is complicated by turbidity characteristic of concentrated solutions of DNA. We have measured the absorption spectra of DNA from calf thymus, Clostridium perfringens, Escherichia coli, Micrococcus luteus, salmon testis, and human placenta using procedures which separate optical density due to true absorption from that due to turbidity. Above 300 nm, the relative absorption of DNA increases as a function of guanine-cytosine content, presumably because the absorption of guanine is much greater than the absorption of adenine at these wavelengths. This result suggests that the photophysical processes which follow absorption of a long-wavelength photon may, on the average, differ from those induced by shorter-wavelength photons. It may also explain the lower quantum yield for the killing of cells by wavelengths above 300 nm compared to that by shorter wavelengths

  11. Magnetic Nature of Light Transmission through a 5-nm Gap.

    Science.gov (United States)

    Yang, Hyosim; Kim, Dai-Sik; Kim, Richard H Joon-Yeon; Ahn, Jae Sung; Kang, Taehee; Jeong, Jeeyoon; Lee, Dukhyung

    2018-02-09

    Slot antennas have been exploited as important building blocks of optical magnetism because their radiations are invoked by the magnetic fields along the axes, as vectorial Babinet principle predicts. However, optical magnetism of a few-nanometer-width slit, for which fascinating applications are found due to the colossal field enhancement but Babinet principle fails due to the nonnegligible thickness, has not been investigated. In this paper, we demonstrated that the magnetic field plays a dominant role in light transmission through a 5-nm slit on a 150-nm-thick gold film. The 5-nm slit was fabricated by atomic layer lithography, and the transmission was investigated for various incident angles by experiment and simulation at 785-nm wavelength. We found that, due to the deep subwavelength gap width, the transmission has the same incident angle dependence as the tangential magnetic field on the metal surface and this magnetic nature of a nanogap holds up to ~100-nm width. Our analysis establishes conditions for nanogap optical magnetism and suggests new possibilities in realizing magnetic-field-driven optical nonlinearities.

  12. Broadband light generation at ~1300 nm through spectrally recoiled solitons and dispersive waves

    DEFF Research Database (Denmark)

    Falk, Peter Andreas; Frosz, Michael Henoch; Bang, Ole

    2008-01-01

    We experimentally study the generation of broadband light at ~1300 nm from an 810 nm Ti:sapphire femtosecond pump laser. We use two photonic crystal fibers with a second infrared zero-dispersion wavelength (λZ2) and compare the efficiency of two schemes: in one fiber λZ2=1400 nm and the light...... at 1300 nm is composed of spectrally recoiled solitons; in the other fiber λZ2=1200 nm and the light at 1300 nm is composed of dispersive waves....

  13. CMOS-NEMS Copper Switches Monolithically Integrated Using a 65 nm CMOS Technology

    Directory of Open Access Journals (Sweden)

    Jose Luis Muñoz-Gamarra

    2016-02-01

    Full Text Available This work demonstrates the feasibility to obtain copper nanoelectromechanical (NEMS relays using a commercial complementary metal oxide semiconductor (CMOS technology (ST 65 nm following an intra CMOS-MEMS approach. We report experimental demonstration of contact-mode nano-electromechanical switches obtaining low operating voltage (5.5 V, good ION/IOFF (103 ratio, abrupt subthreshold swing (4.3 mV/decade and minimum dimensions (3.50 μm × 100 nm × 180 nm, and gap of 100 nm. With these dimensions, the operable Cell area of the switch will be 3.5 μm (length × 0.2 μm (100 nm width + 100 nm gap = 0.7 μm2 which is the smallest reported one using a top-down fabrication approach.

  14. Diode-pumped cw Nd:YAG three-level laser at 869 nm.

    Science.gov (United States)

    Lü, Yanfei; Xia, Jing; Cheng, Weibo; Chen, Jifeng; Ning, Guobin; Liang, Zuoliang

    2010-11-01

    We report for the first time (to our knowledge) a diode-pumped Nd:YAG laser emitting at 869 nm based on the (4)F(3/2)-(4)I(9/2) transition, generally used for a 946 nm emission. Power of 453 mW at 869 nm has been achieved in cw operation with a fiber-coupled laser diode emitting 35.4 W at 809 nm. Intracavity second-harmonic generation in the cw mode has also been demonstrated with power of 118 mW at 435 nm by using a BiB(3)O(6) nonlinear crystal. In our experiment, we used a LiNbO(3) crystal lens to complement the thermal lens of the laser rod, and we obtained good beam quality and high output power stability.

  15. Tapping mode SPM local oxidation nanolithography with sub-10 nm resolution

    International Nuclear Information System (INIS)

    Nishimura, S; Ogino, T; Shirakashi, J; Takemura, Y

    2008-01-01

    Tapping mode SPM local oxidation nanolithography with sub-10 nm resolution is investigated by optimizing the applied bias voltage (V), scanning speed (S) and the oscillation amplitude of the cantilever (A). We fabricated Si oxide wires with an average width of 9.8 nm (V = 17.5 V, S 250 nm/s, A = 292 nm). In SPM local oxidation with tapping mode operation, it is possible to decrease the size of the water meniscus by enhancing the oscillation amplitude of cantilever. Hence, it seems that the water meniscus with sub-10 nm dimensions could be formed by precisely optimizing the oxidation conditions. Moreover, we quantitatively explain the size (width and height) of Si oxide wires with a model based on the oxidation ratio, which is defined as the oxidation time divided by the period of the cantilever oscillation. The model allows us to understand the mechanism of local oxidation in tapping mode operation with amplitude modulation. The results imply that the sub-10 nm resolution could be achieved using tapping mode SPM local oxidation technique with the optimization of the cantilever dynamics

  16. Ablative Fractional 10 600 nm Carbon Dioxide Laser Versus Non-ablative Fractional 1540 nm Erbium-Glass Laser in Egyptian Post-acne Scar patients.

    Science.gov (United States)

    Elsaie, Mohamed L; Ibrahim, Shady M; Saudi, Wael

    2018-01-01

    Introduction: Non-ablative fractional erbium-doped glass 1540 nm and fractional ablative 10600 nm carbon dioxide lasers are regarded as effective modalities for treating acne atrophic scars. In this study, we aimed to compare the effectiveness of fractional CO 2 laser and fractional nonablative 1540 nm erbium doped glass laser in treating post acne atrophic scars in Egyptian patients. Methods: Fifty-eight patients complaining of moderate and severe acne atrophic scars were randomly divided into 2 groups of 29 patients each. Both groups were subjected to 4 treatment sessions with 3 weeks interval and were followed up for 3 months. In group A, enrolled patient sreceived C2 laser, while in group B, patients were treated with 1540 nm erbium glass fractional laser. Results: Clinical assessment revealed that the mean grades of progress and improvement were higher with fractional 10600 nm CO2 laser but with non-significant difference between both treatments ( P = 0.1). The overall patients' satisfaction with both lasers were not significantly different ( P = 0.44). Conclusion: Both fractional ablative CO2 and fractional non-ablative erbium glass lasers are good modalities for treating acne scars with a high efficacy and safety profile and good patient satisfaction. The fractional ablative laser showed higher efficacy while non-ablative laser offered less pain and shorter downtime.

  17. Super ACO FEL oscillation at 300 nm

    CERN Document Server

    Nutarelli, D; Renault, E; Nahon, L; Couprie, Marie Emmanuelle

    2000-01-01

    Some recent improvements, involving both the optical cavity mirrors and the positron beam dynamics in the storage ring, have allowed us to achieve a laser oscillation at 300 nm on the Super ACO Storage Ring FEL. The Super ACO storage ring is operated at 800 MeV which is the nominal energy for the usual synchrotron radiation users, and the highest energy for a storage ring FEL. The lasing at 300 nm could be kept during 2 h per injection, with a stored current ranging between 30 and 60 mA. The FEL characteristics are presented here. The longitudinal stability and the FEL optics behaviour are also discussed.

  18. Interaction between LSD and dopamine D2/3 binding sites in pig brain.

    Science.gov (United States)

    Minuzzi, Luciano; Nomikos, George G; Wade, Mark R; Jensen, Svend B; Olsen, Aage K; Cumming, Paul

    2005-06-15

    The psychoactive properties of the hallucinogen LSD have frequently been attributed to high affinity interactions with serotonin 5HT2 receptors in brain. Possible effects of LSD on dopamine D2/3 receptor availability have not previously been investigated in living brain. Therefore, we used PET to map the binding potential (pB) of [11C]raclopride in brain of three pigs, first in a baseline condition, and again at 1 and 4 h after administration of LSD (2.5 microg/kg, i.v.). There was a progressive treatment effect in striatum, where the pB was significantly reduced by 19% at 4 h after LSD administration. Concomitant maps of cerebral blood flow did not reveal significant changes in perfusion during this interval. Subsequent in vitro studies showed that LSD displaced [3H]raclopride (2 nM) from pig brain cryostat sections with an IC50 of 275 nM according to a one-site model. Fitting of a two-site model to the data suggested the presence of a component of the displacement curves with a subnanomolar IC50, comprising 20% of the total [3H]raclopride binding. In microdialysis experiments, LSD at similar and higher doses did not evoke changes in the interstitial concentration of dopamine or its acidic metabolites in rat striatum. Together, these results are consistent with a direct interaction between LSD and a portion of dopamine D2/3 receptors in pig brain, possibly contributing to the psychopharmacology of LSD. (c) 2005 Wiley-Liss, Inc.

  19. EFFECT OF ALTERNATING WETTING AND DRYING IRRIGATION METHODS ON PHOTOSYNTHESIS AND TEMPERATURE OF RICE AND WEED PLANTS.

    Science.gov (United States)

    Reduced input systems such as alternating wetting and drying (AWD) and furrow irrigation can potentially reduce water costs and limit the release of greenhouse gases in rice production, but also can introduce unwanted crop stresses that compromise crop yield and quality, as well as introducing compl...

  20. MULTISCAN--a Scandinavian multicenter second trimester obstetric ultrasound and serum screening study

    DEFF Research Database (Denmark)

    Jørgensen, F S; Valentin, L; Salvesen, K A

    1999-01-01

    AIM: To study the detection rates of second trimester ultrasound screening for neural tube defects (NTD), abdominal wall defects (AWD) and Down's syndrome (DS) in low risk populations at tertiary centers, and to compare the ultrasound screening detection rates with those that were obtainable by b...

  1. Interspecific variation in physiological and foliar metabolic responses to reduced soil water availability

    Science.gov (United States)

    Climatic uncertainty, particularly in regard to water resources, may alter irrigation management of rice, an essential cereal grain acknowledged as the primary food source for more than half the world’s population. To reduce water use, an alternate wetting and drying (AWD) system has been developed...

  2. Evaluating the Effects of Restraint Systems on 4WD Testing Methodologies: A Collaborative Effort between the NVFEL and ANL

    Science.gov (United States)

    Testing vehicles for emissions and fuel economy has traditionally been conducted with a single-axle chassis dynamometer. The 2006 SAE All Wheel Drive Symposium cited four wheel drive (4WD) and all wheel drive (AWD) sales as climbing from 20% toward 30% of a motor vehicle mar...

  3. Investigating Degradation Mechanisms in 130 nm and 90 nm Commercial CMOS Technologies Under Extreme Radiation Conditions

    Science.gov (United States)

    Ratti, Lodovico; Gaioni, Luigi; Manghisoni, Massimo; Traversi, Gianluca; Pantano, Devis

    2008-08-01

    The purpose of this paper is to study the mechanisms underlying performance degradation in 130 nm and 90 nm commercial CMOS technologies exposed to high doses of ionizing radiation. The investigation has been mainly focused on their noise properties in view of applications to the design of low-noise, low-power analog circuits to be operated in harsh environment. Experimental data support the hypothesis that charge trapping in shallow trench isolation (STI), besides degrading the static characteristics of interdigitated NMOS transistors, also affects their noise performances in a substantial fashion. The model discussed in this paper, presented in a previous work focused on CMOS devices irradiated with a 10 Mrad(SiO2) gamma -ray dose, has been applied here also to transistors exposed to much higher (up to 100 Mrad(SiO2 )) doses of X-rays. Such a model is able to account for the extent of the observed noise degradation as a function of the device polarity, dimensions and operating point.

  4. Extracellular biosynthesis of silver nanoparticles using Bacillus sp. GP-23 and evaluation of their antifungal activity towards Fusarium oxysporum

    Science.gov (United States)

    Gopinath, V.; Velusamy, P.

    2013-04-01

    In last few decades nanoparticles have attracted and emerged as a field in biomedical research due to their incredible applications. The current research was focused on extracellular synthesis of silver nanoparticles (AgNPs) using cell free culture supernatant of strain GP-23. It was found that the strain GP-23 belonged to Bacillus species by 16S rRNA sequence analysis. Biosynthesis of AgNPs was achieved by addition of culture supernatant with aqueous silver nitrate solution, after 24 h it turned to brown color solution with a peak at 420 nm corresponding to the Plasmon absorbance of AgNPs by UV-Vis Spectroscopy. The nanoparticles were characterized by FTIR, XRD, HRTEM, EDX and AFM. The synthesized nanoparticles were found to be spherical in shape with size in the range of 7-21 nm. It was stable in aqueous solution for five months period of storage at room temperature under dark condition. The biosynthesized AgNPs exhibited strong antifungal activity against plant pathogenic fungus, Fusarium oxysporum at the concentration of 8 μg ml-1. The results suggest that the synthesized AgNPs act as an effective antifungal agent/fungicide.

  5. A reflectivity profilometer for the optical characterisation of grade reflectivity mirrors in the 250 nm - 1100 nm spectral region

    Energy Technology Data Exchange (ETDEWEB)

    Colucci, Alessandro; Nichelatti, Enrico [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Innovazione

    1998-04-01

    It`s developed the prototype of an instrument that can be used for the optical characterisation of graded reflectivity mirrors at any wavelength in the spectral region from 250 nm to 1100 nm. The instrument utilises a high-pressure Xe arc lamp as light source. Light is spectrally filtered by means of a grating monochromator. The sample is illuminated with an image of the monochromator exit slit. After reflection from the sample, this image is projected onto a 1024-elements charge-coupled device linear array driven by a digital frame board and interfaced with a personal computer. It`s tested the instrument accuracy by comparing measurement results with the corresponding ones obtained by means of a laser scanning technique. Measurement Rms repeatability has been estimated to be approximately of 0.8%. [Italiano] E` stato sviluppato il prototipo di uno strumento per la catatterizzazione ottica di specchi a riflettivita` variabile, operante a qualsiasi lunghezza d`onda nell`intervallo spettrale da 250 nm a 1100 nm. La sorgente dello strumento e` una lampada ad arco allo Xenon ad alta pressione. La luce e` filtrata spettralmente per mezzo di un monocromatore a reticolo. Il campione viene illuminato da un`immagine della fenditura d`uscita del monocromatore. Dopo essere stata riflessa dal campione, questa immagine viene proiettata su un array CCD lineare a 1024 elementi, connesso elettronicamente a una scheda digitale e interfacciato a un personal computer. L`accuratezza dello strumento e` stata verificata confrontando alcune misure con le corrispondenti misure ottenute mediante una tecnica a scansione laser. La ripetibilita` RMS delle misure e` stata stimata essere circa dello 0.8%.

  6. Laser ablation of ceramic Al{sub 2}O{sub 3} at 193 nm and 248 nm: The importance of single-photon ionization processes

    Energy Technology Data Exchange (ETDEWEB)

    Pelaez, R. J.; Afonso, C. N. [Laser Processing Group, Instituto de Optica, CSIC, Serrano 121, Madrid 28006 (Spain); Bator, M.; Lippert, T. [General Energy Research Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2013-06-14

    The aim of this work is to demonstrate that single-photon photoionization processes make a significant difference in the expansion and temperature of the plasma produced by laser ablation of ceramic Al{sub 2}O{sub 3} in vacuum as well as to show their consequences in the kinetic energy distribution of the species that eventually will impact on the film properties produced by pulsed laser deposition. This work compares results obtained by mass spectrometry and optical spectroscopy on the composition and features of the plasma produced by laser ablation at 193 nm and 248 nm, i.e., photon energies that are, respectively, above and below the ionization potential of Al, and for fluences between threshold for visible plasma and up to Almost-Equal-To 2 times higher. The results show that the ionic composition and excitation of the plasma as well as the ion kinetic energies are much higher at 193 nm than at 248 nm and, in the latter case, the population of excited ions is even negligible. The comparison of Maxwell-Boltzmann temperature, electron temperatures, and densities of the plasmas produced with the two laser wavelengths suggests that the expansion of the plasma produced at 248 nm is dominated by a single population. Instead, the one produced at 193 nm is consistent with the existence of two populations of cold and hot species, the latter associated to Al{sup +} ions that travel at the forefront and produced by single photon ionization as well as Al neutrals and double ionized ions produced by electron-ion impact. The results also show that the most energetic Al neutrals in the plasma produced at the two studied wavelengths are in the ground state.

  7. On the origins of 718 nm fluorescence from Porphyridium cruentum at 77 K.

    Science.gov (United States)

    Wang, R T; Graham, J R; Myers, J

    1980-09-05

    Emission spectra and transient behavior of fluorescence in Porphyridium cruentum have been studied in search of the pathway of excitation energy from the phycobilisome to Photosystem I (PS I) of photosynthesis. For activating light at 436 nm, absorbed almost entirely by chlorophyll, fluorescence is dominated by the 718 nm band generally attributed to chlorophyll of PS I. Activating light at 550 nm, absorbed mostly by the phycobilisome, gives rise to the distinctive fluorescence band of PS II chlorophyll at 696 nm but also gives a large component at 718 nm. Analysis depends critically upon the source of emission at 718 nm under 550 nm activation: does it arise from PS I or PS IIC0 Ley and Butler (Ley, A.C. and Butler, W.L. (1976) Proc. Natl. Acad. Sci. U.S.A. 73, 3956-3960) have proposed that the 718 nm arises mostly from PS I, to which it is transferred by spillover from PS II. We suggest a different proposition: that under 550 nm activation most of the 718 emission arises from PS II. Analysis shows that this proposition provides an alternative explanation. Using the small change in fluorescence yield observed under 436 nm activation as a monitor of excitation in PS I, we provide evidence that under 550 activation most of the 718 nm fluorescence arises from PS II.

  8. 32nm and below logic patterning using optimized illumination and double patterning

    Science.gov (United States)

    Smayling, Michael C.; Axelrad, Valery

    2009-03-01

    Line/space dimensions for 32nm generation logic are expected to be ~45-50nm at ~90-100nm pitch. It is likely that the node will begin at the upper end of the range, and then shrink by ~10% to a "28nm" node. For the lower end of the range, even with immersion scanners, the Rayleigh k1 factor is below 0.32. The 22nm logic node should begin with minimum pitches of approximately 70nm, requiring some form of double patterning to maintain k1 above 0.25. Logic patterning has been more difficult than NAND Flash patterning because random logic was designed with complete "freedom" compared to the very regular patterns used in memory. The logic layouts with bends and multiple pitches resulted in larger rules, un-optimized illumination, and a poorly understood process windows with little control of context-dependent "hot spots."[1] The introduction of logic design styles which use strictly one-directional lines for the critical levels now gives the opportunity for illumination optimization. Gridded Design Rules (GDR) have been demonstrated to give areacompetitive layouts at existing 90, 65, and 45nm logic nodes while reducing CD variability.[2] These benefits can be extended to <=32nm logic using selective double pass patterning.

  9. Semiconductor optical amplifiers for the 1000-1100-nm spectral range

    International Nuclear Information System (INIS)

    Lobintsov, A A; Shramenko, M V; Yakubovich, S D

    2008-01-01

    Two types of semiconductor optical amplifiers (SOAs) based on a double-layer quantum-well (InGa)As/(GaAl)As/GaAs heterostructure are investigated. The optical gain of more than 30 dB and saturation output power of more than 30 mW are achived at 1060 nm in pigtailed SOA modules. These SOAs used as active elements of a tunable laser provide rapid continuous tuning within 85 nm and 45 nm at output powers of 0.5 mW and more than 30 mW, respectively. (active media, lasers, and amplifiers)

  10. Widely Tunable High-Power Tapered Diode Laser at 1060 nm

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Sumpf, Bernd; Erbert, Götz

    2011-01-01

    We report a large tuning range from 1018 to 1093 nm from a InGaAs single quantum-well 1060-nm external cavity tapered diode laser. More than 2.5-W output power has been achieved. The tuning range is to our knowledge the widest obtained from a high-power InGaAs single quantum-well tapered laser...... operating around 1060 nm. The light emitted by the laser has a nearly diffraction limited beam quality and a narrow linewidth of less than 6 pm everywhere in the tuning range....

  11. Photochemistry of acrylates at 222 nm

    International Nuclear Information System (INIS)

    Knolle, Wolfgang; Naumov, Sergej; Madani, Mohamed; Sonntag, Clemens von

    2005-01-01

    Excimer lamps as monochromatic UV sources with an intense short-wavelength emission (especially KrCl * , 222 nm) allow a photoinitiator-free initiation of the acrylate polymerisation. Laser photolysis (KrCl * excimer laser, pulse width 20 ns, up to 5 mJ per pulse) gives rise to similar transient spectra (λ max ∼ 280 nm) for all acrylates studied. As the rather unspecific spectra do not allow conclusions as to the main reaction channel, a product study has been performed by GC-MS following steady-state photolysis of acrylate solutions in acetonitrile, methanol and n-hexane. Somewhat unexpected, α-cleavage seems to be a main reaction channel, and quantum chemical calculations show that such a reaction can occur from either the excited singlet state or the unrelaxed triplet state, but not from the relaxed triplet state that is observed spectroscopically. A reaction scheme accounting for the observed products is presented

  12. TUNABLE DIODE LASER MEASUREMENTS OF NO2 NEAR 670 NM AND 395 NM. (R823933)

    Science.gov (United States)

    Two single-mode diode lasers were used to record high-resolution absorption spectra of NO2 (dilute in Ar) near 670.2 and 394.5 nm over a range of temperatures (296 to 774 K) and total pressures (2.4 x 10(-2) to 1 atm). A commercial InGaAsP laser was tuned 1.3 cm(-1) at a repetiti...

  13. Sub-10-nm suspended nano-web formation by direct laser writing

    Science.gov (United States)

    Wang, Sihao; Yu, Ye; Liu, Hailong; Lim, Kevin T. P.; Madurai Srinivasan, Bharathi; Zhang, Yong Wei; Yang, Joel K. W.

    2018-06-01

    A diffraction-limited three-dimensional (3D) direct laser writing (DLW) system based on two-photon polymerization can routinely pattern structures at the 100 nm length scale. Several schemes have been developed to improve the patterning resolution of 3D DLW but often require customized resist formulations or multi-wavelength exposures. Here, we introduce a scheme to produce suspended nano-webs with feature sizes below 10 nm in IP-Dip resist using sub-threshold exposure conditions in a commercial DLW system. The narrowest suspended lines (nano-webs) measured 7 nm in width. Larger ∼20 nm nano-webs were patterned with ∼80% yield at increased laser powers. In addition, closely spaced nano-gaps with a center-to-center distance of 33 nm were produced by patterning vertically displaced suspended lines followed by metal deposition and liftoff. We provide hypotheses and present preliminary results for a mechanism involving the initiation of a percolative path and a strain-induced narrowing in the nano-web formation. Our approach allows selective features to be patterned with dimensions comparable to the sub-10 nm patterning capability of electron-beam lithography (EBL).

  14. Generation of continuous-wave 194 nm laser for mercury ion optical frequency standard

    Science.gov (United States)

    Zou, Hongxin; Wu, Yue; Chen, Guozhu; Shen, Yong; Liu, Qu; Precision measurement; atomic clock Team

    2015-05-01

    194 nm continuous-wave (CW) laser is an essential part in mercury ion optical frequency standard. The continuous-wave tunable radiation sources in the deep ultraviolet (DUV) region of the spectrum is also serviceable in high-resolution spectroscopy with many atomic and molecular lines. We introduce a scheme to generate continuous-wave 194 nm radiation with SFM in a Beta Barium Borate (BBO) crystal here. The two source beams are at 718 nm and 266 nm, respectively. Due to the property of BBO, critical phase matching (CPM) is implemented. One bow-tie cavity is used to resonantly enhance the 718 nm beam while the 266 nm makes a single pass, which makes the configuration easy to implement. Considering the walk-off effect in CPM, the cavity mode is designed to be elliptical so that the conversion efficiency can be promoted. Since the 266 nm radiation is generated by a 532 nm laser through SHG in a BBO crystal with a large walk-off angle, the output mode is quite non-Gaussian. To improve mode matching, we shaped the 266 nm beam into Gaussian modes with a cylindrical lens and iris diaphragm. As a result, 2.05 mW 194 nm radiation can be generated. As we know, this is the highest power for 194 nm CW laser using SFM in BBO with just single resonance. The work is supported by the National Natural Science Foundation of China (Grant No. 91436103 and No. 11204374).

  15. Creep deformation behavior at long-term in P23/T23 steels

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, K.; Tabuchi, M.; Kimura, K. [National Institute for Materials Science (Japan)

    2008-07-01

    Creep behavior of ASME P23/T23 steels was investigated and analyzed, focusing on creep strength degradation at long-term. Creep rupture strength at 625 C and 650 C dropped at long-term in both P23 and T23 steels. The stress exponent of minimum creep rate at 625 C and 650 C was 7.8-13 for higher stresses and 3.9-5.3 for lower stresses in the P23/T23 steels. The change of stress exponent with stress levels was consistent with the drop in creep rupture strength at long-term. The Monkman-Grant rule was confirmed in the range examined in P23 steel, while the data points deviated from the rule at long-term in the case of T23 steel. The creep ductility of P23 steel was high over a wide stress and temperature range. On the other hand, in T23 steel, creep ductility at 625 C and 650 C decreased as time to rupture increased. The change in ductility may cause the deviation from the Monkman-Grant rule. Fracture mode changed from transgranular to intergranular fracture in the long-term at 625 C and 650 C. (orig.)

  16. Organic matter and water management strategies to reduce methane and nitrous oxide emissions from rice paddies in Vietnam

    DEFF Research Database (Denmark)

    Pandey, Arjun; Mai, Van Trinh; Duong, Quynh Vu

    2014-01-01

    with the safe alternate wetting and drying (AWD) has the potential to suppress both CH4 and N2O emissions from rice paddies while maintaining the rice yield. The study compared the proposed strategies with local farmers' practice of permanent flooding (PF) and farmyard manure (FYM) incorporation, respectively...

  17. Flight distance in roe deer Capreolus capreolus and fallow deer Dama dama as related to hunting and other factors

    NARCIS (Netherlands)

    Boer, de H.Y.; Breukelen, van L.; Hootsmans, M.J.M.; Wieren, van S.E.

    2004-01-01

    Flight distances in roe deer Capreolus capreolus and fallow deer Dama dama with respect to a human observer on foot were measured in four nature reserves in the Netherlands: two dune reserves in the western part (the Amsterdam Water Supply Dunes (AWD) and Kennemerduinen (KD)) and two forested areas

  18. Nitrogen cycling under alternate wetting and drying cycles in Arkansas rice

    Science.gov (United States)

    Alternate wetting and drying (AWD) cycles offer potential savings in water use for paddy rice production while reducing both greenhouse gas emissions and lowering grain arsenic content. In a three-year (2011-2013) field study near Stuttgart, AR, one-third of a field previously grown to soybean was b...

  19. Multiferroic behavior on nanometric La2/3Ca1/3MnO3 / BaTiO3 bilayers

    Science.gov (United States)

    Prieto, Pedro; Ordoñez, John Edward; Gomez, Maria Elena; Lopera, Wilson

    2014-03-01

    We have deposited bilayers of the FM La2/3Ca1/3MnO3 and FE BaTiO3 as a route to design systems with artificial magnetoelectric coupling on LCMO/BTO/Nb:STO system. We maintain a fixed magnetic layer thickness (tLCMO = 48 nm) and varying the thickness of the ferroelectric layer (tBTO = 20, 50, 100 nm). We analyze the influence of the thickness ratio (tBTO/ tLCMO) in electrical and magnetic properties of manganite. From X-ray diffraction analysis we observed that the samples grew textured. Magnetization and transport measurements indicate a possible multiferroic behavior in the bilayer. We found an increase in the Curie and metal-insulator transition temperature in the bilayer in comparison with those for LCMO (48nm)/STO. Hysteresis loops on bilayers show ferromagnetic behavior. This work has been supported by the ``El Patrimonio Autónomo Fondo Nacional de Financiamiento para CT&I FJC'' Colciencias-CENM Research Projects: No. 1106-48-925531 and CI7917-CC 10510 contract 0002-2013 COLCIENCIAS-UNIVALLE.

  20. Evaluation of fertilizer and water management effect on rice performance and greenhouse gas intensity in different seasonal weather of tropical climate.

    Science.gov (United States)

    Ku, Hyun-Hwoi; Hayashi, Keiichi; Agbisit, Ruth; Villegas-Pangga, Gina

    2017-12-01

    Intensively double cropping rice increases greenhouse gas (GHG) emission in tropical countries, and hence, finding better management practices is imperative for reducing global warming potential (GWP), while sustaining rice yield. This study demonstrated an efficient fertilizer and water management practice targeting seasonal weather conditions effects on rice productivity, nitrogen use efficiency (NUE), GWP, and GHG intensity (GHGI). Two-season experiments were conducted with two pot-scale experiments using urea and urea+cattle manure (CM) under continuous flooding (CF) during the wet season (2013WS), and urea with/without CaSiO 3 application under alternate wetting and drying (AWD) during the dry season (2014DS). In 2013WS, 120kgNha -1 of urea fertilizer resulted in lower CH 4 emission and similar rice production compared to urea+CM. In 2014DS, CaSiO 3 application showed no difference in yields and led to significant reduction of N 2 O emission, but increased CH 4 emission and GWP. Due to significant increases in GHG emissions in urea+CM and CaSiO 3 application, we compared a seasonal difference in a local rice cultivation to test two water management practices. CF was adopted during 2013WS while AWD was adopted during 2014DS. Greater grain yields and yield components and NUE were obtained in 2014DS than in 2013WS. Furthermore, higher grain yields contributed to similar values of GHGI although GWP of cumulative GHG emissions was increased in 2014DS. Thus, utilizing urea only application under AWD is a preferred practice to minimize GWP without yield decline for double cropping rice in tropical countries. Copyright © 2017. Published by Elsevier B.V.

  1. Mechanistic comparison of pulse laser induced phase separation of particulates from cellulose paper at 213 nm and 532 nm

    International Nuclear Information System (INIS)

    Arif, S.; Forster, M.; Kautek, W.; Bushuk, S.; Kouzmouk, A.; Tatur, H.; Batishche, S.

    2013-01-01

    The laser-induced phase separation of charcoal particles on additive-free cotton linters cellulose paper was investigated by electron and optical microscopy, colorimetry, and diffuse reflectance FT-IR. The fibre bundles were vaporised in depth of several 10 μm above destruction fluence thresholds using visible 532 nm radiation. This is in contrast to mid-ultraviolet 213 nm radiation, where only the top fibre bundles were modified and partially evaporated. The colorimetric lightness results generally represented the cleaning status, whereas the colorimetric yellowing data represented irreversible chemical and/or photochemical changes. Charcoal-contaminated paper treated with visible and mid-ultraviolet radiation exhibited yellowing, whereas uncontaminated did not. This suggests that the electron-rich plasma generated by the evaporation of the particles heats the adjacent substrate and also excludes oxygen. Mid-ultraviolet, in contrast to visible radiation, shows particle removal always accompanied by paper destruction. IR spectroscopy results suggest cross-linking by ether bonds near the destruction threshold, but do not prove the formation of oxidation products and double bonds as the basis of the yellowing. A ''cleaning window'' between the cleaning threshold (0.1 J/cm 2 ) and the paper destruction threshold (2.9 J/cm 2 ) with a pulse number of 2 is provided by visible 532 nm laser treatment. (orig.)

  2. Toward the Synthesis of Sub-15 nm Ag Nanocubes with Sharp Corners and Edges: The Roles of Heterogeneous Nucleation and Surface Capping.

    Science.gov (United States)

    Ruditskiy, Aleksey; Xia, Younan

    2016-03-09

    We report a polyol method for the facile synthesis of Ag nanocubes having sharp corners and edges, together with edge lengths below 15 nm. The rapid nucleation of Ag atoms was facilitated through the addition of a trace amount of SH(-) to generate Ag2S clusters while the corners and edges of the nanocubes were sharpened through the introduction of Br(-) as a regulator of the growth kinetics and a capping agent for the Ag(100) surface. Because of their much smaller size relative to the more commonly used capping agent based on poly(vinylpyrrolidone), Br(-) ions are more effective in passivating the {100} facets on very small Ag nanocubes. The mechanistic roles of these additives, along with the effects of their interactions with other species present in the reaction solution, were all systematically investigated. The concentration of SH(-) was found to be a particularly effective parameter for tuning the edge length of the nanocubes. As a result of the understanding gained during the course of this study, Ag nanocubes with uniform edge lengths controllable in the range of 13-23 nm could be reliably produced. The nanocubes of 13.4 ± 0.4 nm in edge length constitute the smallest nanocrystals of this kind reported to date; they also possess sharper corners and edges relative to the limited examples of sub-20 nm Ag nanocubes reported in the literature. The availability of such small and sharp Ag nanocubes will open the door to an array of applications in plasmonics, catalysis, and biomedicine.

  3. Power and efficiency scaling of diode pumped Cr:LiSAF lasers: 770-1110 nm tuning range and frequency doubling to 387-463 nm.

    Science.gov (United States)

    Demirbas, Umit; Baali, Ilyes

    2015-10-15

    We report significant average power and efficiency scaling of diode-pumped Cr:LiSAF lasers in continuous-wave (cw), cw frequency-doubled, and mode-locked regimes. Four single-emitter broad-area laser diodes around 660 nm were used as the pump source, which provided a total pump power of 7.2 W. To minimize thermal effects, a 20 mm long Cr:LiSAF sample with a relatively low Cr-concentration (0.8%) was used as the gain medium. In cw laser experiments, 2.4 W of output power, a slope efficiency of 50%, and a tuning range covering the 770-1110 nm region were achieved. Intracavity frequency doubling with beta-barium borate (BBO) crystals generated up to 1160 mW of blue power and a record tuning range in the 387-463 nm region. When mode locked with a saturable absorber mirror, the laser produced 195 fs pulses with 580 mW of average power around 820 nm at a 100.3 MHz repetition rate. The optical-to-optical conversion efficiency of the system was 33% in cw, 16% in cw frequency-doubled, and 8% in cw mode-locked regimes.

  4. Deposition and characterization of ITO films produced by laser ablation at 355 nm

    DEFF Research Database (Denmark)

    Holmelund, E.; Thestrup Nielsen, Birgitte; Schou, Jørgen

    2002-01-01

    Indium tin oxide (ITO) films have been deposited by pulsed laser deposition (PLD) at 355 nm. Even though the absorption of laser light at the wavelength 355 nm is much smaller than that of the standard excimer lasers for PLD at 248 nm and 193 nm, high-quality films can be produced. At high fluence...

  5. Treatment of burn scars in Fitzpatrick phototype III patients with a combination of pulsed dye laser and non-ablative fractional resurfacing 1550 nm erbium:glass/1927 nm thulium laser devices.

    Science.gov (United States)

    Tao, Joy; Champlain, Amanda; Weddington, Charles; Moy, Lauren; Tung, Rebecca

    2018-01-01

    Burn scars cause cosmetic disfigurement and psychosocial distress. We present two Fitzpatrick phototype (FP) III patients with burn scars successfully treated with combination pulsed dye laser (PDL) and non-ablative fractional lasers (NAFL). A 30-year-old, FP III woman with a history of a second-degree burn injury to the bilateral arms and legs affecting 30% body surface area (BSA) presented for cosmetic treatment. The patient received three treatments with 595 nm PDL (7 mm, 8 J, 6 ms), six with the 1550 nm erbium:glass laser (30 mJ, 14% density, 4-8 passes) and five with the 1927 nm thulium laser (10 mJ, 30% density, 4-8 passes). Treated burn scars improved significantly in thickness, texture and colour. A 33-year-old, FP III man with a history of a second-degree burn injury of the left neck and arm affecting 7% BSA presented for cosmetic treatment. The patient received two treatments with 595 nm PDL (5 mm, 7.5 J, 6 ms), four with the 1550 nm erbium:glass laser (30 mJ, 14% density, 4-8 passes) and two with the 1927 nm thulium laser (10 mJ, 30% density, 4-8 passes). The burn scars became thinner, smoother and more normal in pigmentation and appearance. Our patients' burn scars were treated with a combination of PDL and NAFL (two wavelengths). The PDL targets scar hypervascularity, the 1550 nm erbium:glass stimulates collagen remodelling and the 1927 nm thulium targets epidermal processes, particularly hyperpigmentation. This combination addresses scar thickness, texture and colour with a low side effect profile and is particularly advantageous in patients at higher risk of post-procedure hyperpigmentation. Our cases suggest the combination of 595nm PDL plus NAFL 1550 nm erbium:glass/1927 nm thulium device is effective and well-tolerated for burn scar treatment in skin of colour.

  6. Nearest-IR superluminescent diodes with a 100-nm spectral width

    Energy Technology Data Exchange (ETDEWEB)

    Il' chenko, S N; Ladugin, M A; Marmalyuk, Aleksandr A; Yakubovich, S D

    2012-11-30

    This paper presents an experimental study of quantum well superluminescent diodes with an extremely thin (InGa)As active layer. Under cw injection, the output power of such diodes is several milliwatts, with a centre wavelength of 830 nm and emission bandwidth of about 100 nm. (letters)

  7. Fluorescence Imaging In Vivo at Wavelengths beyond 1500 nm.

    Science.gov (United States)

    Diao, Shuo; Blackburn, Jeffrey L; Hong, Guosong; Antaris, Alexander L; Chang, Junlei; Wu, Justin Z; Zhang, Bo; Cheng, Kai; Kuo, Calvin J; Dai, Hongjie

    2015-12-01

    Compared to imaging in the visible and near-infrared regions below 900 nm, imaging in the second near-infrared window (NIR-II, 1000-1700 nm) is a promising method for deep-tissue high-resolution optical imaging in vivo mainly owing to the reduced scattering of photons traversing through biological tissues. Herein, semiconducting single-walled carbon nanotubes with large diameters were used for in vivo fluorescence imaging in the long-wavelength NIR region (1500-1700 nm, NIR-IIb). With this imaging agent, 3-4 μm wide capillary blood vessels at a depth of about 3 mm could be resolved. Meanwhile, the blood-flow speeds in multiple individual vessels could be mapped simultaneously. Furthermore, NIR-IIb tumor imaging of a live mouse was explored. NIR-IIb imaging can be generalized to a wide range of fluorophores emitting at up to 1700 nm for high-performance in vivo optical imaging. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Peculiarities of near-ultraviolet (365 nm) and visible light effects in Paramecium Caudatum cells

    International Nuclear Information System (INIS)

    Samoilova, K.A.; Sushchenko, N.B.

    1977-01-01

    After treatment with 365 nm or visible light Paramecium caudatum cells fail to divide and die shortly after irradiation; no death occurs long after irradiation, as well as after several cell cycles, unlike the situation after the action of 254 nm or 300-380 nm. Irradiation inhibits mainly the first cell cycle following which the recovery of cells starts. Thus no after-effects take place after the action of 365 nm and visible light, and the patterns of their effects are rather similar. The photoreactivation of damages induced by 365 nm is quite small, being about 2 times less than that for 254 nm and 300-380 nm. Similarity of the action of 254, 300-380, 365 nm and visible light was established by the stimulation of cell division by low doses and increase in viability of infusoria from cultures with low survival and depressed rate of multiplication. This effect of 365 nm is not eliminated by visible light; moreover, the latter promotes the 'therapeutic' effect of the 365 nm line. (author)

  9. Surgical performance of a 405-nm diode laser in treatment of soft tissue

    International Nuclear Information System (INIS)

    Kato, J; Akashi, G; Moriya, K; Hirai, Y; Hatayama, H; Inoue, A; Miyazaki, H

    2008-01-01

    The study was conducted to evaluate the surgical performance of a 405-nm diode laser ex vivo. The experiments were carried out using tuna tissue, which was irradiated with a 405-nm diode laser at output powers of 400 mW (694 W/cm 2 ) to 1 W (1735 W/cm 2 ) on a motorized stage moving at a rate of 1 mm/sec. As a control, a 920-nm diode laser was used with the same irradiation conditions. After irradiation, the thickness of ablation and coagulation was measured by stereoscopic microscopy and evaluated statistically. Ablation and coagulation zones were obtained with 405-nm laser irradiation, but not with irradiation at 920 nm. Ablation depth increased significantly with output power and a thick coagulation zone was observed with 405-nm irradiation. The 405-nm diode laser performed well for incising and coagulating soft tissue at a low power density

  10. COPD phenotypes on computed tomography and its correlation with selected lung function variables in severe patients

    Directory of Open Access Journals (Sweden)

    da Silva SMD

    2016-03-01

    Full Text Available Silvia Maria Doria da Silva, Ilma Aparecida Paschoal, Eduardo Mello De Capitani, Marcos Mello Moreira, Luciana Campanatti Palhares, Mônica Corso PereiraPneumology Service, Department of Internal Medicine, School of Medical Sciences, State University of Campinas (UNICAMP, Campinas, São Paulo, BrazilBackground: Computed tomography (CT phenotypic characterization helps in understanding the clinical diversity of chronic obstructive pulmonary disease (COPD patients, but its clinical relevance and its relationship with functional features are not clarified. Volumetric capnography (VC uses the principle of gas washout and analyzes the pattern of CO2 elimination as a function of expired volume. The main variables analyzed were end-tidal concentration of carbon dioxide (ETCO2, Slope of phase 2 (Slp2, and Slope of phase 3 (Slp3 of capnogram, the curve which represents the total amount of CO2 eliminated by the lungs during each breath.Objective: To investigate, in a group of patients with severe COPD, if the phenotypic analysis by CT could identify different subsets of patients, and if there was an association of CT findings and functional variables.Subjects and methods: Sixty-five patients with COPD Gold III–IV were admitted for clinical evaluation, high-resolution CT, and functional evaluation (spirometry, 6-minute walk test [6MWT], and VC. The presence and profusion of tomography findings were evaluated, and later, the patients were identified as having emphysema (EMP or airway disease (AWD phenotype. EMP and AWD groups were compared; tomography findings scores were evaluated versus spirometric, 6MWT, and VC variables.Results: Bronchiectasis was found in 33.8% and peribronchial thickening in 69.2% of the 65 patients. Structural findings of airways had no significant correlation with spirometric variables. Air trapping and EMP were strongly correlated with VC variables, but in opposite directions. There was some overlap between the EMP and AWD

  11. Absolutely calibrated vacuum ultraviolet spectra in the 150-250-nm range from plasmas generated by the NIKE KrF laser

    International Nuclear Information System (INIS)

    Seely, J.F.; Feldman, Uri; Holland, G.E.; Weaver, J.L.; Mostovych, A.N.; Obenschain, S.P.; Schmitt, A.J.; Lehmberg, R.; Kjornarattanawanich, Benjawan; Back, C.A.

    2005-01-01

    High-resolution vacuum ultraviolet (VUV) spectra were recorded from plasmas generated by the NIKE KrF laser for the purpose of observing emission from the two-plasmon decay instability (TPDI) at 2/3 the NIKE wavelength (165 nm). The targets were irradiated by up to 43 overlapping beams with intensity up to ≅10 14 W/cm 2 and with beam smoothing by induced spatial incoherence (ISI). The targets consisted of planar foils of CH, BN, Al, Si, S, Ti, Pd, and Au. Titanium-doped silica aerogels in Pyrex cylinders were also irradiated. The spectra of the target elements were observed from charge states ranging from the neutral atoms to five times ionized. The spectrometer was absolutely calibrated using synchrotron radiation, and absolute VUV plasma emission intensities were determined. Emission from the TPDI at 165-nm wavelength was not observed from any of the irradiated targets. An upper bound on the possible TPDI emission was less than 4x10 -8 the incident NIKE laser energy. The NIKE laser radiation backscattered from the silica aerogel targets at 248 nm was typically 6x10 -6 the incident NIKE laser energy, and the spectral broadening corresponded to the 1-THz bandwidth of the ISI smoothing. The spectra from the moderately charged plasma ions (up to five times ionized), spectral linewidths, absolute continuum emission level, and slope of the continuum were consistent with plasma temperatures in the 100-300-eV range

  12. Comparison of 850-nm and 1550-nm VCSELs for low-cost short-reach IM/DD and OFDM SMF/MMF links

    DEFF Research Database (Denmark)

    Karinou, Fotini; Deng, Lei; Rodes Lopez, Roberto

    2013-01-01

    In this paper, we experimentally compare the suitability of two VCSEL designs of different wavelength and technology as inexpensive, off-the-shelf transmitter components to enable low-cost and energy-efficient optical interconnects employing conventional (NRZ IM/DD) and advanced (OFDM) modulation....... In particular, we assess the performance of a multimode (MM) 850-nm and a single-mode (SM) 1550-nm VCSEL over 100 m/1 km of 50.7-μm diameter OM-4 MMF links and 100 m/5 km SMF links. OFDM-QPSK is investigated in order to substitute IM/DD in order to increase the capacity in the aforementioned VCSEL-based, MMF...

  13. UV-induced modifications in the peptidyl transferase loop of 23S rRNA dependent on binding of the streptogramin B antibiotic, pristinamycin IA

    DEFF Research Database (Denmark)

    Porse, B T; Kirillov, S V; Awayez, M J

    1999-01-01

    The naturally occurring streptogramin B antibiotic, pristinamycin IA, which inhibits peptide elongation, can produce two modifications in 23S rRNA when bound to the Escherichia coli 70S ribosome and irradiated at 365 nm. Both drug-induced effects map to highly conserved nucleotides within...... in the latter modification to A2062/C2063. Pristinamycin IA can also produce a modification on binding to deproteinized, mature 23S rRNA, at position U2500/C2501. The same modification occurs on an approximately 37-nt fragment, encompassing positions approximately 2496-2532 of the peptidyl transferase loop...... the sequence Cm-C-U-C-G-m2A-psi-G2505 are important for pristinamycin IA binding and/or the antibiotic-dependent modification of 23S rRNA....

  14. Fibroblast Growth Factor 23 (FGF23 and Disorders of Phosphate Metabolism

    Directory of Open Access Journals (Sweden)

    Tasuku Saito

    2009-01-01

    Full Text Available Derangements in serum phosphate level result in rickets/osteomalacia or ectopic calcification indicating that healthy people without these abnormalities maintain serum phosphate within certain ranges. These results indicate that there must be a regulatory mechanism of serum phosphate level. Fibroblast growth factor 23 (FGF23 was identified as the last member of FGF family. FGF23 is produced by bone and reduces serum phosphate level by suppressing phosphate reabsorption in proximal tubules and intestinal phosphate absorption through lowering 1,25-dihydroxyvitamin D level. It has been shown that excess and deficient actions of FGF23 result in hypophosphatemic rickets/osteomalacia and hyperphosphatemic tumoral calcinosis, respectively. These results indicate that FGF23 works as a hormone, and several disorders of phosphate metabolism can be viewed as endocrine diseases. It may become possible to treat patients with abnormal phosphate metabolism by pharmacologically modifying the activity of FGF23.

  15. Optical breakdown threshold investigation of 1064 nm laser induced air plasmas

    International Nuclear Information System (INIS)

    Thiyagarajan, Magesh; Thompson, Shane

    2012-01-01

    We present the theoretical and experimental measurements and analysis of the optical breakdown threshold for dry air by 1064 nm infrared laser radiation and the significance of the multiphoton and collisional cascade ionization process on the breakdown threshold measurements over pressures range from 10 to 2000 Torr. Theoretical estimates of the breakdown threshold laser intensities and electric fields are obtained using two distinct theories namely multiphoton and collisional cascade ionization theories. The theoretical estimates are validated by experimental measurements and analysis of laser induced breakdown processes in dry air at a wavelength of 1064 nm by focusing 450 mJ max, 6 ns, 75 MW max high-power 1064 nm IR laser radiation onto a 20 μm radius spot size that produces laser intensities up to 3 - 6 TW/cm 2 , sufficient for air ionization over the pressures of interest ranging from 10 to 2000 Torr. Analysis of the measured breakdown threshold laser intensities and electric fields are carried out in relation with classical and quantum theoretical ionization processes, operating pressures. Comparative analysis of the laser air breakdown results at 1064 nm with corresponding results of a shorter laser wavelength (193 nm) [M. Thiyagarajan and J. E. Scharer, IEEE Trans. Plasma Sci. 36, 2512 (2008)] and a longer microwave wavelength (10 8 nm) [A. D. MacDonald, Microwave Breakdown in Gases (Wiley, New York, 1966)]. A universal scaling analysis of the breakdown threshold measurements provided a direct comparison of breakdown threshold values over a wide range of frequencies ranging from microwave to ultraviolet frequencies. Comparison of 1064 nm laser induced effective field intensities for air breakdown measurements with data calculated based on the collisional cascade and multiphoton breakdown theories is used successfully to determine the scaled collisional microwave portion. The measured breakdown threshold of 1064 nm laser intensities are then scaled to

  16. Results from a new 193nm die-to-database reticle inspection platform

    Science.gov (United States)

    Broadbent, William H.; Alles, David S.; Giusti, Michael T.; Kvamme, Damon F.; Shi, Rui-fang; Sousa, Weston L.; Walsh, Robert; Xiong, Yalin

    2010-05-01

    A new 193nm wavelength high resolution reticle defect inspection platform has been developed for both die-to-database and die-to-die inspection modes. In its initial configuration, this innovative platform has been designed to meet the reticle qualification requirements of the IC industry for the 22nm logic and 3xhp memory generations (and shrinks) with planned extensions to the next generation. The 22nm/3xhp IC generation includes advanced 193nm optical lithography using conventional RET, advanced computational lithography, and double patterning. Further, EUV pilot line lithography is beginning. This advanced 193nm inspection platform has world-class performance and the capability to meet these diverse needs in optical and EUV lithography. The architecture of the new 193nm inspection platform is described. Die-to-database inspection results are shown on a variety of reticles from industry sources; these reticles include standard programmed defect test reticles, as well as advanced optical and EUV product and product-like reticles. Results show high sensitivity and low false and nuisance detections on complex optical reticle designs and small feature size EUV reticles. A direct comparison with the existing industry standard 257nm wavelength inspection system shows measurable sensitivity improvement for small feature sizes

  17. Efficiency of soft tissue incision with a novel 445-nm semiconductor laser.

    Science.gov (United States)

    Braun, Andreas; Kettner, Moritz; Berthold, Michael; Wenzler, Johannes-Simon; Heymann, Paul Günther Baptist; Frankenberger, Roland

    2018-01-01

    Using a 445-nm semiconductor laser for tissue incision, an effective cut is expected due to the special absorption properties of blue laser light in soft tissues. The aim of the present study was the histological evaluation of tissue samples after incision with a 445-nm diode laser. Forty soft tissue specimens were obtained from pork oral mucosa and mounted on a motorized linear translation stage. The handpiece of a high-frequency surgery device, a 970-nm semiconductor laser, and a 445-nm semiconductor laser were connected to the slide, allowing a constant linear movement (2 mm/s) and the same distance of the working tip to the soft tissue's surface. Four incisions were made each: (I) 970-nm laser with conditioned fiber tip, contact mode at 3-W cw; (II-III): 445-nm laser with non-conditioned fiber tip, contact mode at 2-W cw, and non-contact mode (1 mm) at 2 W; and (IV): high-frequency surgery device with straight working tip, 90° angulation, contact mode at 50 W. Histological analysis was performed after H&E staining of the embedded specimens at 35-fold magnification. The comparison of the incision depths showed a significant difference depending on the laser wavelength and the selected laser parameters. The highest incision depth was achieved with the 445-nm laser contact mode (median depth 0.61 mm, min 0.26, max 1.17, interquartile range 0.58) (p laser, a higher cutting efficiency can be expected when compared with a 970-nm diode laser and high-frequency surgery. Even the 445-nm laser application in non-contact mode shows clinically acceptable incision depths without signs of extensive soft tissue denaturation.

  18. Fluorescence-based calculus detection using a 405-nm excitation wavelength

    Science.gov (United States)

    Brede, O.; Schelle, F.; Krueger, S.; Oehme, B.; Dehn, C.; Frentzen, M.; Braun, A.

    2011-03-01

    The aim of this study was to assess the difference of fluorescence signals of cement and calculus using a 405 nm excitation wavelength. A total number of 20 freshly extracted teeth was used. The light source used for this study was a blue LED with a wavelength of 405nm. For each tooth the spectra of calculus and cementum were measured separately. Fluorescence light was collimated into an optical fibre and spectrally analyzed using an echelle spectrometer (aryelle 200, Lasertechnik Berlin, Germany) with an additionally bandpass (fgb 67, Edmund Industrial Optics, Karlsruhe, Germany). From these 40 measurements the median values were calculated over the whole spectrum, leading to two different median spectra, one for calculus and one for cementum. For further statistical analysis we defined 8 areas of interest (AOI) in wavelength regions, showing remarkable differences in signal strength. In 7 AOIs the intensity of the calculus spectrum differed statistically significant from the intensity of the cementum spectrum (p calculus and cement between 600nm and 700nm. Thus, we can conclude that fluorescence of calculus shows a significant difference to the fluorescence of cement. A differentiation over the intensity is possible as well as over the spectrum. Using a wavelength of 405nm, it is possible to distinguish between calculus and cement. These results could be used for further devices to develop a method for feedback controlled calculus removal.

  19. Pre-storm NmF2 enhancements at middle latitudes: delusion or reality?

    Directory of Open Access Journals (Sweden)

    A. V. Mikhailov

    2009-03-01

    Full Text Available A critical analysis of recent publications devoted to the NmF2 pre-storm enhancements is performed. There are no convincing arguments that the observed cases of NmF2 enhancements at middle and sub-auroral latitudes bear a relation to the following magnetic storms. In all cases considered the NmF2 pre-storm enhancements were due to previous geomagnetic storms, moderate auroral activity or they presented the class of positive quiet time events (Q-disturbances. Therefore, it is possible to conclude that there is no such an effect as the pre-storm NmF2 enhancement as a phenomenon inalienably related to the following magnetic storm. The observed nighttime NmF2 enhancements at sub-auroral latitudes may result from plasma transfer from the plasma ring area by meridional thermospheric wind. Enhanced plasmaspheric fluxes into the nighttime F2-region resulted from westward substorm-associated electric fields is another possible source of nighttime NmF2 enhancements. Daytime positive Q-disturbances occurring under very low geomagnetic activity level may be related to the dayside cusp activity.

  20. Interaction of pulse laser radiation of 532 nm with model coloration layers for medieval stone artefacts

    Energy Technology Data Exchange (ETDEWEB)

    Colson, J. [University of Vienna, Department of Physical Chemistry, A-1090 Vienna (Austria); Nimmrichter, J. [Austrian Federal Office for the Care of Monuments, Department for Conservation and Restoration, Arsenal, Objekt 15, Tor 4, A-1030 Vienna (Austria); Kautek, W., E-mail: wolfgang.kautek@univie.ac.at [University of Vienna, Department of Physical Chemistry, A-1090 Vienna (Austria)

    2014-05-01

    Multilayer polychrome coatings on medieval and Renaissance stone artefacts represent substantial challenges in laser cleaning. Therefore, polychromic models with classical pigments, minium (Pb{sub 2}{sup 2+}Pb{sup 4+}O{sub 4}), zinc white (ZnO), and lead white ((PbCO{sub 3}){sub 2}·Pb(OH){sub 2}) in an acrylic binder, were irradiated with a Q-switched Nd:YAG laser emitting at 532 nm. The studied medieval pigments exhibit strongly varying incubation behaviours directly correlated to their band gap energies. Higher band gaps beyond the laser photon energy of 2.3 eV require more incubative generation of defects for resonant transitions. A matching of the modification thresholds after more than four laser pulses was observed. Laser cleaning with multiple pulsing should not exceed ca. 0.05 J/cm{sup 2} when these pigments coexist in close spatial proximity.

  1. Relationship of 2,3-diphosphoglycerate and 2,3-diphosphoglycerate mutase in various mammals.

    Science.gov (United States)

    Chemtob, S; Gibb, W; Bard, H

    1980-01-01

    To investigate a possible mechanism involved in the regulation of 2,3-diphosphoglycerate (2,3-DPG) synthesis, 2,3-DPG mutase (DPGM) was measured in different mammals presenting large differences in 2,3-DPG concentration between fetal, neonatal and adult life to see the activity of this enzyme, necessary for 2,3-DPG synthesis, was related to the levels of 2,3-DPG. The data demonstrated that the minimal levels of 2,3-DPG in the adult sheep are likely due to the very low levels of DPGM. Also these findings show that the increases in 2,3-DPG levels, found in the newborn sheep during the 1st week of life, in adult rabbit and guinea pig when compared with their fetuses, are not due to an increase in levels of the DPGM.

  2. Mechanistic comparison of pulse laser induced phase separation of particulates from cellulose paper at 213 nm and 532 nm

    Energy Technology Data Exchange (ETDEWEB)

    Arif, S.; Forster, M.; Kautek, W. [University of Vienna, Department of Physical Chemistry, Wien (Austria); Bushuk, S.; Kouzmouk, A.; Tatur, H.; Batishche, S. [National Academy of Sciences of the Republic of Belarus, Institute of Physics, Minsk (Belarus)

    2013-02-15

    The laser-induced phase separation of charcoal particles on additive-free cotton linters cellulose paper was investigated by electron and optical microscopy, colorimetry, and diffuse reflectance FT-IR. The fibre bundles were vaporised in depth of several 10 {mu}m above destruction fluence thresholds using visible 532 nm radiation. This is in contrast to mid-ultraviolet 213 nm radiation, where only the top fibre bundles were modified and partially evaporated. The colorimetric lightness results generally represented the cleaning status, whereas the colorimetric yellowing data represented irreversible chemical and/or photochemical changes. Charcoal-contaminated paper treated with visible and mid-ultraviolet radiation exhibited yellowing, whereas uncontaminated did not. This suggests that the electron-rich plasma generated by the evaporation of the particles heats the adjacent substrate and also excludes oxygen. Mid-ultraviolet, in contrast to visible radiation, shows particle removal always accompanied by paper destruction. IR spectroscopy results suggest cross-linking by ether bonds near the destruction threshold, but do not prove the formation of oxidation products and double bonds as the basis of the yellowing. A ''cleaning window'' between the cleaning threshold (0.1 J/cm{sup 2}) and the paper destruction threshold (2.9 J/cm{sup 2}) with a pulse number of 2 is provided by visible 532 nm laser treatment. (orig.)

  3. Jeremiah 23:23–24 as polemic against prophets' views on Yahweh's ...

    African Journals Online (AJOL)

    2016-05-31

    May 31, 2016 ... Yahweh is also a distant God who is aware of their false and deceitful attempts to provide revelatory knowledge to the people. In this regard chapter 23:23–24 serves as a polemic against so-called false prophets and implies a threat of judgement. Jeremiah 23:23–24 as polemic against prophets' views on ...

  4. Characterisation of a smartphone image sensor response to direct solar 305nm irradiation at high air masses.

    Science.gov (United States)

    Igoe, D P; Amar, A; Parisi, A V; Turner, J

    2017-06-01

    This research reports the first time the sensitivity, properties and response of a smartphone image sensor that has been used to characterise the photobiologically important direct UVB solar irradiances at 305nm in clear sky conditions at high air masses. Solar images taken from Autumn to Spring were analysed using a custom Python script, written to develop and apply an adaptive threshold to mitigate the effects of both noise and hot-pixel aberrations in the images. The images were taken in an unobstructed area, observing from a solar zenith angle as high as 84° (air mass=9.6) to local solar maximum (up to a solar zenith angle of 23°) to fully develop the calibration model in temperatures that varied from 2°C to 24°C. The mean ozone thickness throughout all observations was 281±18 DU (to 2 standard deviations). A Langley Plot was used to confirm that there were constant atmospheric conditions throughout the observations. The quadratic calibration model developed has a strong correlation between the red colour channel from the smartphone with the Microtops measurements of the direct sun 305nm UV, with a coefficient of determination of 0.998 and very low standard errors. Validation of the model verified the robustness of the method and the model, with an average discrepancy of only 5% between smartphone derived and Microtops observed direct solar irradiances at 305nm. The results demonstrate the effectiveness of using the smartphone image sensor as a means to measure photobiologically important solar UVB radiation. The use of ubiquitous portable technologies, such as smartphones and laptop computers to perform data collection and analysis of solar UVB observations is an example of how scientific investigations can be performed by citizen science based individuals and groups, communities and schools. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Mapping the Use of Engineered NM in Quebec's Industries and Research Laboratories

    International Nuclear Information System (INIS)

    Ostiguy, Claude; Emond, Claude; Dossa, Inès; Plavski, Anton; Malki, Yasmina; Boily, Chantale; Roughley, David; Endo, Charles-Anica

    2013-01-01

    Engineered NanoMaterials (NM) offer an opportunity to develop a wide variety of new products with unique properties but many studies have shown potential OHS risks specific to NM. Addressing these risks requires knowledge about release of NM into the workplaces. This research aimed to map the state of nanotechnology OHS practices in Quebec through a questionnaire following a first contact by telephone when possible and by compiling the type and volumes of NM used as well as gathering information related to the working conditions and OHS aspects. This survey was conducted among 1310 Quebec industries and 653 researchers working in different specialties potentially involved in the development/production/distribution/integration of NM and use of NM containing products. Overall, 90 questionnaires, including 51 from the industries, were completed. These showed that NM are mainly used into the powder form, in many different sectors and deserve a wide range of markets. The prevention measures implemented vary widely from a workplace to another but about one third of the participants report that they have implemented NP adapted prevention measures but they remain worried on some specific operations. More than 50% of the participants request more information about the safe laboratory/plant design, toxicity, regulation, good work practices and prevention measures, efficiency of personal protective equipment and environmental impacts.

  6. Mapping the Use of Engineered NM in Quebec's Industries and Research Laboratories

    Science.gov (United States)

    Ostiguy, Claude; Emond, Claude; Dossa, Inès; Malki, Yasmina; Boily, Chantale; Roughley, David; Plavski, Anton; Endo, Charles-Anica

    2013-04-01

    Engineered NanoMaterials (NM) offer an opportunity to develop a wide variety of new products with unique properties but many studies have shown potential OHS risks specific to NM. Addressing these risks requires knowledge about release of NM into the workplaces. This research aimed to map the state of nanotechnology OHS practices in Quebec through a questionnaire following a first contact by telephone when possible and by compiling the type and volumes of NM used as well as gathering information related to the working conditions and OHS aspects. This survey was conducted among 1310 Quebec industries and 653 researchers working in different specialties potentially involved in the development/production/distribution/integration of NM and use of NM containing products. Overall, 90 questionnaires, including 51 from the industries, were completed. These showed that NM are mainly used into the powder form, in many different sectors and deserve a wide range of markets. The prevention measures implemented vary widely from a workplace to another but about one third of the participants report that they have implemented NP adapted prevention measures but they remain worried on some specific operations. More than 50% of the participants request more information about the safe laboratory/plant design, toxicity, regulation, good work practices and prevention measures, efficiency of personal protective equipment and environmental impacts.

  7. Photoelectron Emission Studies in CsBr at 257 nm

    International Nuclear Information System (INIS)

    Maldonado, Juan R.; Liu, Zhi; Sun, Yun; Pianetta, Piero A.; Pease, Fabian W.

    2006-01-01

    CsBr/Cr photocathodes were found [1,2] to meet the requirements of a multi-electron beam lithography system operating with a light energy of 4.8 eV (257nm). The fact that photoemission was observed with a light energy below the reported 7.3 eV band gap for CsBr was not understood. This paper presents experimental results on the presence of intra-band gap absorption sites (IBAS) in CsBr thin film photo electron emitters, and presents a model based on IBAS to explain the observed photoelectron emission behavior at energies below band gap. A fluorescence band centered at 330 nm with a FWHM of about 0.34 eV was observed in CsBr/Cr samples under 257 nm laser illumination which can be attributed to IBAS and agrees well with previously obtained synchrotron photoelectron spectra[1] from the valence band of CsBr films

  8. A reflectivity profilometer for the optical characterisation of graded reflectivity mirrors in the 250 nm - 1100 nm spectral region

    International Nuclear Information System (INIS)

    Colucci, Alessandro; Nichelatti, Enrico

    1998-04-01

    It's developed the prototype of an instrument that can be used for the optical characterisation of graded reflectivity mirrors at any wavelength in the spectral region from 250 nm to 1100 nm. The instrument utilises a high-pressure Xe arc lamp as light source. Light is spectrally filtered by means of a grating monochromator. The sample is illuminated with an image of the monochromator exit slit. After reflection from the sample, this image is projected onto a 1024-elements charge-coupled device linear array driven by a digital frame board and interfaced with a personal computer. It's tested the instrument accuracy by comparing measurement results with the corresponding ones obtained by means of a laser scanning technique. Measurement Rms repeatability has been estimated to be approximately of 0.8% [it

  9. 20 W continuous-wave cladding-pumped Nd-doped fiber laser at 910 nm.

    Science.gov (United States)

    Laroche, M; Cadier, B; Gilles, H; Girard, S; Lablonde, L; Robin, T

    2013-08-15

    We demonstrate a double-clad fiber laser operating at 910 nm with a record power of 20 W. Laser emission on the three-level scheme is enabled by the combination of a small inner cladding-to-core diameter ratio and a high brightness pump source at 808 nm. A laser conversion efficiency as high as 44% was achieved in CW operating regime by using resonant fiber Bragg reflectors at 910 nm that prevent the lasing at the 1060 nm competing wavelength. Furthermore, in a master oscillator power-amplifier scheme, an amplified power of 14.8 W was achieved at 914 nm in the same fiber.

  10. Irradiation Effect of Argon Ion on Interfacial Structure Fe(2nm/Si(tsi=0.5-2 nm Multilayer thin Film

    Directory of Open Access Journals (Sweden)

    S. Purwanto

    2010-04-01

    Full Text Available Investigation includes formation of interfacial structure of Fe(2nm/Si(tSi= 0.5-2 nm multilayer thin film and the behavior of antiferromagnetic coupling between Fe layers due to Argon ion irradiation was investigated. [Fe(2nm/Si]30 multilayers (MLs with a thickness of Si spacer 0.5 - 2 nanometer were prepared on n-type (100 Si substrate by the helicon plasma sputtering method. Irradiation were performed using 400keV Ar ion to investigate the behavior of magnetic properties of the Fe/Si MLs. The magnetization measurements of Fe/Si MLs after 400keV Ar ion irradiation show the degradation of antiferromagnetic behavior of Fe layers depend on the ion doses. The Magnetoresistance (MR measurements using by Four Point Probe (FPP method also confirm that MR ratio decrease after ion irradiation. X-ray diffraction (XRD patterns indicate that the intensity of a satellite peak induced by a superlattice structure does not change within the range of ion dose. These results imply that the surface of interface structures after ion irradiation become rough although the layer structures are maintained. Therefore, it is considered that the MR properties of Fe/Si MLs also are due to the metallic superlattice structures such as Fe/Cr and Co/Cu MLs.

  11. Fibroblast growth factor 23

    African Journals Online (AJOL)

    Dr Olaleye

    Systemic phosphate homeostasis is maintained through several hormonal mechanisms which involve fibroblast growth factor 23 (FGF-23), α-klotho, vitamin D and parathyroid hormone. FGF-23 is known to be the major regulator of phosphate balance (Mirams et al., 2004). FGF-23 is a phosphaturic hormone, which is.

  12. 23 CFR 505.17 - Applicability of Title 23, U.S. Code.

    Science.gov (United States)

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Applicability of Title 23, U.S. Code. 505.17 Section 505... INFRASTRUCTURE MANAGEMENT PROJECTS OF NATIONAL AND REGIONAL SIGNIFICANCE EVALUATION AND RATING § 505.17 Applicability of Title 23, U.S. Code. Funds made available to carry out this section shall be available for...

  13. Aerosol extinction profiles at 525 nm and 1020 nm derived from ACE imager data: comparisons with GOMOS, SAGE II, SAGE III, POAM III, and OSIRIS

    Directory of Open Access Journals (Sweden)

    F. Vanhellemont

    2008-04-01

    Full Text Available The Canadian ACE (Atmospheric Chemistry Experiment mission is dedicated to the retrieval of a large number of atmospheric trace gas species using the solar occultation technique in the infrared and UV/visible spectral domain. However, two additional solar disk imagers (at 525 nm and 1020 nm were added for a number of reasons, including the retrieval of aerosol and cloud products. In this paper, we present first comparison results for these imager aerosol/cloud optical extinction coefficient profiles, with the ones derived from measurements performed by 3 solar occultation instruments (SAGE II, SAGE III, POAM III, one stellar occultation instrument (GOMOS and one limb sounder (OSIRIS. The results indicate that the ACE imager profiles are of good quality in the upper troposphere/lower stratosphere, although the aerosol extinction for the visible channel at 525 nm contains a significant negative bias at higher altitudes, while the relative differences indicate that ACE profiles are almost always too high at 1020 nm. Both problems are probably related to ACE imager instrumental issues.

  14. All-solid-state cw frequency-doubling Nd:YLiF4/LBO blue laser with 4.33 W output power at 454 nm under in-band diode pumping at 880 nm.

    Science.gov (United States)

    Lü, Yanfei; Zhang, Xihe; Cheng, Weibo; Xia, Jing

    2010-07-20

    We generated efficient blue laser output at 454 nm by intracavity frequency doubling of a continuous-wave (cw) diode-pumped Nd:YLiF(4) (Nd:YLF) laser at 908 nm based on the (4)F(3/2)-(4)I(9/2) transition. With 32.8 W of incident pump power at 880 nm and the frequency-doubling crystal LiB(3)O(5), a level as high as 4.33 W of cw output power at 454 nm is achieved, corresponding to an optical conversion efficiency of 13.2% with respect to the incident pump power. To the best of our knowledge, this is the first blue laser at 454 nm generated by intracavity frequency doubling of a diode-pumped Nd:YLF.

  15. Repair of 313-nm induced lesions and photoprotection in yeast Candida guilliermondii

    International Nuclear Information System (INIS)

    Fraikin, G.Y.; Pospelov, M.E.; Rubin, L.B.

    1977-01-01

    The present communication is concerned with the effects of near-UV radiation (300-380 nm) on yeast Candida guilliermondii. It was found that certain doses of 313 nm irradiation caused inactivation of the yeast which was exhibited in a way different from the lethal action of far-UV radiation. It was also found that the cells inactivated by 313 nm are capable of recovering vitality, if incubated for some time in a non-nutrient medium. The yeast inactivated by far-UV radiation also proved to be capable of recovering, though to a lesser degree. Both 334 nm radiation and non-lethal doses at 313 nm induced the photoprotective effect against far-UV damage. The effect was exhibited if there was a certain time interval (2-4 h) between the exposures to photoprotective light and subsequent far-UV radiation. Within this time interval the extent of photoprotection was dependent on temperature. (author)

  16. SPECTROPHOTOMETRIC DETERMINATION OF ACETYLCYSTEINE IN PHARMACEUTICAL FORMULATIONS USING 2,3-DICHLORO-1,4-NAPTHOQUINONE

    Directory of Open Access Journals (Sweden)

    A. O. Donchenko

    2015-04-01

    Full Text Available The aim of research was the development and validation ofspectrophotometric method foracetylcysteine assay in pharmaceutical formulations.Тhe proposed method is based on the reaction with 2,3-dichloro-1,4-naphthoquinone and the formation of colored products that exhibit absorption maxima at 425 nm. Introduction Many analytical methods have been published for acetylcysteine assay in pharmaceutical formulations as high-performance liquid chromatography (HPLC, fluorimetry and chemiluminescence. Some of these methods are time consuming or require expensive equipment. Other published methods suffer from lack of selectivity and sensitivity. Spectrophotometry is the most widely used technique in pharmaceutical analysis because it is simple, economic, and easily available to most quality control laboratories. In the present work, we propose a simple and accurate spectrophotometric method for acetylcysteine assay in pharmaceutical formulations. Materials and Methods Reagents: Reference standard acetylcysteinesubstance; 2,3-dichloro-1,4-naphthoquinone. All chemicals and solvents were of analytical grade. DMFA was used as a solvent. Pharmaceutical preparations:powder for oral solution «ACC 200» 200 mgseries number50026151 (Salutas Pharma CmbH, Germany; effervescent tablets «Fluimucil» 600 mg (Zambon S.P.A., Italy and «ACC LONG» 600 mg (Salutas Pharma CmbH, Germany series numbers 321284 and DH2740; solution for injections «Fluimucil» 100 mg/ml (Zambon S.P.A., Italyseries number28002492. Solutions: Acetylcysteine stock solution (0,16%; DMFAsolution of 2,3-dichloro-1,4-naphthoquinone (4%. Equipment Analytical balance (ABT-120-5DM; UV-VIS spectrophotometer (Specord 200; water bath (MemmertWNB 7-45;quartz cells. Results Acetylcysteine was determined using a spectrophotometric method based on the reaction with 2,3-dichloro-1,4-naphthoquinone to form yellow colored reaction products with absorption maxima at 425 nm. The effect of reaction time and

  17. Wide-Field Imaging of Single-Nanoparticle Extinction with Sub-nm2 Sensitivity

    Science.gov (United States)

    Payne, Lukas M.; Langbein, Wolfgang; Borri, Paola

    2018-03-01

    We report on a highly sensitive wide-field imaging technique for quantitative measurement of the optical extinction cross section σext of single nanoparticles. The technique is simple and high speed, and it enables the simultaneous acquisition of hundreds of nanoparticles for statistical analysis. Using rapid referencing, fast acquisition, and a deconvolution analysis, a shot-noise-limited sensitivity down to 0.4 nm2 is achieved. Measurements on a set of individual gold nanoparticles of 5 nm diameter using this method yield σext=(10.0 ±3.1 ) nm2, which is consistent with theoretical expectations and well above the background fluctuations of 0.9 nm2 .

  18. Size-driven magnetic transitions in La1/3Ca2/3MnO3 nanoparticles

    Science.gov (United States)

    Markovich, V.; Fita, I.; Wisniewski, A.; Mogilyansky, D.; Puzniak, R.; Titelman, L.; Gorodetsky, G.

    2010-09-01

    Magnetic properties of electron-doped La1/3Ca2/3MnO3 manganite nanoparticles with average particle size ranging from 12 to 42 nm, prepared by the glycine-nitrate method, have been investigated in temperature range 5-300 K and in magnetic fields up to 90 kOe. Reduction in the particle size suppresses antiferromagnetism and decreases the Néel temperature. In contrast to bulk crystals, the charge ordering does not occur in all studied nanoparticles, while a weak ferromagnetism appears above 200 K. Low temperature magnetic hysteresis loops indicate upon exchange bias effect displayed by horizontal and vertical shifts in field cooled processes. The spontaneous and remanent magnetization at low temperature shows a relatively complex variation with particle size. The size-induced structural/magnetic disorder drives the La1/3Ca2/3MnO3 nanoparticles to a pronounced glassy behavior for the smallest 12 nm particles, as evidenced by large difference between zero field cooled and field cooled magnetization, frequency dependent ac-susceptibility, as well as characteristic slowing down in the spin dynamics. Time evolution of magnetization recorded in magnetic fields after field cooling to low temperatures exhibits pronounced relaxation and a very noisy behavior that may be caused by formation of some collective states. Magnetic properties of the nanoparticle samples are compared with those of La0.2Ca0.8MnO3 nanoparticles. These results shed some light on the coupling between charges and spin degrees of freedom in antiferromagnetic manganite nanoparticles.

  19. Prototyping the HPDP Chip on STM 65 NM Process

    Science.gov (United States)

    Papadas, C.; Dramitinos, G.; Syed, M.; Helfers, T.; Dedes, G.; Schoellkopf, J.-P.; Dugoujon, L.

    2011-08-01

    Currently Astrium GmbH is involved in the of the High Performance Data Processor (HPDP) development programme for telecommunication applications under a DLR contract. The HPDP project targets the implementation of the commercially available reconfigurable array processor IP (XPP from the company PACT XPP Technologies) in a radiation hardened technology.In the current complementary development phase funded under the Greek Industry Incentive scheme, it is planned to prototype the HPDP chip in commercial STM 65 nm technology. In addition it is also planned to utilise the preliminary radiation hardened components of this library wherever possible.This abstract gives an overview of the HPDP chip architecture, the basic details of the STM 65 nm process and the design flow foreseen for the prototyping. The paper will discuss the development and integration issues involved in using the STM 65 nm process (also including the available preliminary radiation hardened components) for designs targeted to be used in space applications.

  20. Sub-10-nm Graphene Nanoribbons with Tunable Surface Functionalities for Lithium-ion Batteries

    International Nuclear Information System (INIS)

    Li, Yan-Sheng; Ao, Xiang; Liao, Jia-Liang; Jiang, Jianjun; Wang, Chundong; Chiang, Wei-Hung

    2017-01-01

    Highlights: •A green and scalable method to produce sub-10-nm GNR is present. •The surface functionality of sub-10-nm GNR is critical for the LIB properties. •The sub-10-nm GNR showed superior LIB capacity of 490.4 mAh g −1 after 100 cycles. -- Abstract: A systematic study to reveal the relationship between the surface oxygen-containing functionalities of sub-10-nm GNRs and their electrochemical properties for lithium-ion batteries has been presented. Sub-10-nm GNRs with controlled oxygen-containing groups were synthesized by a green and scalable intercalation-assisted unzipping SWCNTs. Detailed materials characterizations including TEM, XRD, Raman and XPS indicate that KNO 3 could be an effective intercalation agent to facilitate the SWCNT unzipping by reducing the strong Van der Waals force attraction of bundled SWCNT. The levels of surface functionalities of sub-10-nm GNR were tuned by carefully controlling the KMnO 4 concentration during the unzipping process. The electrochemical analysis suggests that the as-produced sub-10-nm GNR with 31.4 atomic percent (atom %) oxygen-containing functional groups showed the highest capacity of 490.4 mAh g −1 after 100 cycles. This work proposed that sub-10-nm GNRs with appropriate oxygen-functional groups can be a promising electrode material for high performance lithium-ion batteries.

  1. Scaling of light emission from detonating bare Composition B, 2,4,6-trinitrotoluene [C7H5(NO2)3], and PE4 plastic explosive charges

    CSIR Research Space (South Africa)

    Mostert, FJ

    2011-10-01

    Full Text Available and configuration. In this study, the emission characteristics at wavelengths between 650 and 940 nm were experimentally investigated for cylindrical bare Composition B, 2,4,6-trinitrotoluene [C7H5(NO2)3], and PE4 plastic explosive charges in the mass (M) range of 0...

  2. 308-nm excimer laser for the treatment of alopecia areata.

    Science.gov (United States)

    Al-Mutairi, Nawaf

    2007-12-01

    Alopecia areata is loss of hair from localized or diffuse areas of hair-bearing area of the skin. Recently there are reports of efficacy of the 308-nm excimer radiation for this condition. To study the effect of the 308-nm excimer laser in the treatment of alopecia areata. Eighteen patients with 42 recalcitrant patches (including 1 adult with alopecia totalis) were enrolled in this study. The lesions were treated with the 308-nm excimer laser twice a week for a period of 12 weeks; one lesion on each patient was left as a control for comparison. There were 7 males and 11 females in this study. Regrowth of hair was observed in 17 (41.5%) patches. Thirteen of the 18 lesions in scalp showed a complete regrowth of hair. The extremity regions failed to show a response. Atopic diatheses had an unfavorable effect on the outcome in our patients. The 308-nm excimer laser is an effective therapeutic option for patchy alopecia areata of the scalp and for some cases with patchy alopecia areata of the beard area. It does not work for patchy alopecia areata of the extremities.

  3. Moodsad ja võimekad

    Index Scriptorium Estoniae

    2014-01-01

    TM võrdleb: nelikveolised universaalid: Audi A4 Allroad 2,0 TDI Quattro S tronic, Opel Insignia Country Tourer 2,0 CDTI BiTurbo 4×4 A, Peugeot 508 RXH HYbrid4, Subaru Outback 2,0 D Lineartronic, Volkswagen Passat Alltrack 2,0 TDI 4Motion DSG, Volvo XC70 D4 Momentum AWD

  4. Ion transport in sub-5-nm graphene nanopores

    International Nuclear Information System (INIS)

    Suk, Myung E.; Aluru, N. R.

    2014-01-01

    Graphene nanopore is a promising device for single molecule sensing, including DNA bases, as its single atom thickness provides high spatial resolution. To attain high sensitivity, the size of the molecule should be comparable to the pore diameter. However, when the pore diameter approaches the size of the molecule, ion properties and dynamics may deviate from the bulk values and continuum analysis may not be accurate. In this paper, we investigate the static and dynamic properties of ions with and without an external voltage drop in sub-5-nm graphene nanopores using molecular dynamics simulations. Ion concentration in graphene nanopores sharply drops from the bulk concentration when the pore radius is smaller than 0.9 nm. Ion mobility in the pore is also smaller than bulk ion mobility due to the layered liquid structure in the pore-axial direction. Our results show that a continuum analysis can be appropriate when the pore radius is larger than 0.9 nm if pore conductivity is properly defined. Since many applications of graphene nanopores, such as DNA and protein sensing, involve ion transport, the results presented here will be useful not only in understanding the behavior of ion transport but also in designing bio-molecular sensors

  5. Evidence for stepwise dissociation dynamics in acetone at 248 and 193 nm

    Science.gov (United States)

    North, Simon W.; Blank, David A.; Gezelter, J. Daniel; Longfellow, Cheryl A.; Lee, Yuan T.

    1995-03-01

    The technique of molecular beam photofragment translational spectroscopy has been used to study the dissociation of acetone following S1←S0 (248 nm) and S2←S0 (193 nm) excitation. Excitation at 248 nm resulted in the production of CH3 and CH3CO with 14.2±1.0 kcal/mole on average of the available energy appearing as translation of the photofragments. Comparison of the measured with values reported at 266 nm suggest that the energy partitioning is dominated by the exit barrier caused by an avoided crossing on the potential energy surface. A substantial fraction (30±4%) of the nascent acetyl radicals from the primary dissociation contain sufficient energy to undergo spontaneous secondary decomposition. From the onset of the truncation of the CH3CO P(ET) a threshold of 17.8±3.0 kcal/mole for the dissociation of the acetyl radical has been determined in agreement with recent results on the photodissociation of acetyl chloride. The translational energy release in the dissociation of CH3CO closely matches the experimentally determined exit barrier. At 193 nm the only observed dissociation pathway was the formation of two methyl radicals and carbon monoxide. On average ˜38% of the available energy is found in product translation suggesting that significant internal energy resides in the nascent CH3 fragments consistent with the results of Hall et al. [J. Chem. Phys. 94, 4182 (1991)]. We conclude that the dynamics and energy partitioning for dissociation at 193 nm is similar to that at 248 nm.

  6. UO{sub 2} Kernel Preparation by M-EG Process and Its Irradiation Test

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, K. C.; Eom, S. H.; Kim, Y. K.; Yeo, S. H.; Kim, Y. M.; Kim, B. G.; Cho, M. S. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Kernels of KAERI TRISO fuels are prepared in the following steps: (1) preparation of a raw material solution(UN solution) by UO{sub 3} (or U{sub 3}O{sub 8}) powder dissolution in the concentrated HNO{sub 3}; (2) broth preparation and physical property control by mixing UN, THFA, PVA, and H{sub 2}O; (3) preparation of spherical liquid gel droplets and dried-ADU gels in sequence through a reaction between uranyl ions and ammonia ions in a gelation column; (4) ageing, washing, and drying processes of ADU gel using AWD equipment; (5) UO{sub 3} calcination by thermal decomposition of driedADU gel in the air; (6) fabrication of UO{sub 2} kernel by reducing the UO{sub 3} and sintering in the H{sub 2}. In this study, improved KAERI processes for UO{sub 2} kernel preparation were presented. ADU gel washing procedure in AWD processes and the heating mode in sintering process were modified and the internal structures of UO{sub 2} kernels are presented as a result.

  7. Anomalous variations of NmF2 over the Argentine Islands: a statistical study

    Directory of Open Access Journals (Sweden)

    A. V. Pavlov

    2009-04-01

    Full Text Available We present a statistical study of variations in the F2-layer peak electron density, NmF2, and altitude, hmF2, over the Argentine Islands ionosonde. The critical frequencies, foF2, and, foE, of the F2 and E-layers, and the propagation factor, M(3000F2, measured by the ionosonde during the 1957–1959 and 1962–1995 time periods were used in the statistical analysis to determine the values of NmF2 and hmF2. The probabilities to observe maximum and minimum values of NmF2 and hmF2 in a diurnal variation of the electron density are calculated. Our study shows that the main part of the maximum diurnal values of NmF2 is observed in a time sector close to midnight in November, December, January, and February exhibiting the anomalous diurnal variations of NmF2. Another anomalous feature of the diurnal variations of NmF2 exhibited during November, December, and January when the minimum diurnal value of NmF2 is mainly located close to the noon sector. These anomalous diurnal variations of NmF2 are found to be during both geomagnetically quiet and disturbed conditions. Anomalous features are not found in the diurnal variations of hmF2. The statistical study of the NmF2 winter anomaly phenomena over the Argentine Islands ionosonde was carried out. The variations in a maximum daytime value, R, of a ratio of a geomagnetically quiet daytime winter NmF2 to a geomagnetically quiet daytime summer NmF2 taken at a given UT and for approximately the same level of solar activity were studied. The conditional probability of the occurrence of R in an interval of R, the most frequent value of R, the mean expected value of R, and the conditional probability to observe the F2-region winter anomaly during a daytime period were calculated for low, moderate, and high solar activity. The calculations show that the mean expected value of R and the occurrence frequency of the F2-region winter anomaly increase with increasing solar activity.

  8. Negative-tone imaging with EUV exposure for 14nm hp and beyond

    Science.gov (United States)

    Tsubaki, Hideaki; Nihashi, Wataru; Tsuchihashi, Toru; Fujimori, Toru; Momota, Makoto; Goto, Takahiro

    2015-03-01

    Manipulation of dissolution properties by changing organic solvent developer and rinse material provides a novel technology to obtain fine pattern beyond the limitation of imaging system based on alkaline developer. QCM study showed no swelling character in negative-tone imaging (NTI) process even for current developer of n-butyl acetate (nBA). Actually, NTI process has shown advantages on resolution and line-width roughness (LWR) in loose pitch around 30 ~ 45 nm hp as a consequence of its non-swelling character. On the other hand, bridge and collapse limited its resolution below 20 nm hp, indicating that non-negligible amount of swelling still exists for tight pitch resolution. We investigated effects of solubility parameter of organic solvents on resolution below 20 nm hp. A bridge was reduced with a decrease in the solubility parameter dp from nBA. On the other hand, much lower dp caused film remaining due to its extremely slow Rmax. Based on these results, we newly developed FN-DP301 containing organic solvent with smaller dp than nBA. Although rinse solvent gave negligible effects on bridge, there is a clear improvement on pattern collapse only in case of using new rinse solvent of FN-RP311. Lithographic performances of NTI process using nBA and FN-DP301 together with the other organic solvents were described in this paper under exposures with an E-beam and a EUV light. It is emphasized that 14 nm hp resolution was obtained only using FN-DP301 as a developer and FN-RP311 as a rinse under E-beam exposure. NTI showed 43% faster photospeed in comparison with PTI at 16 nm hp, indicating that NTI is applicable to obtain high throughput with maintaining resolution. In addition, sub-20 nm trench was obtained using NTI without bridge under EUV exposure, all of which are attributed to the low swelling character of NTI process. Similarly, NTI was able to print 20 nm dots using NXE:3100 with only a little peeling. Conversely CH patterning was significantly worse with NTI

  9. Evaluation of a Low Energy, Low Density, Non-Ablative Fractional 1927 nm Wavelength Laser for Facial Skin Resurfacing.

    Science.gov (United States)

    Brauer, Jeremy A; Alabdulrazzaq, Hamad; Bae, Yoon-Soo Cindy; Geronemus, Roy G

    2015-11-01

    We investigated the safety, tolerability and efficacy of a low energy low density, non-ablative fractional 1,927-nm laser in the treatment of facial photodamage, melasma, and post inflammatory hyperpigmentation. Prospective non-randomized trial. Single center, private practice with a dedicated research department. Subjects with clinically diagnosed facial photodamage, melasma, or post inflammatory hyperpigmentation. Subjects received four to six treatments at 14-day intervals (+/- 3 days) with a low energy low density non-ablative fractional 1,927-nm laser (Solta Hayward, CA) with an energy level of 5 mJ, and density coverage of either 5%, 7.5%, or 10%, with a total of up to 8 passes. Blinded assessment of clinical photos for overall improvement at one and three months post final treatment. Investigator improvement scores, and subject pain and satisfaction scores for overall improvement were recorded as well. We enrolled 23 subjects, average age 45.0 years (range, 25-64 years), 22 with Fitzpatrick Skin Types I-IV and 1 with Type VI, with facial photodamage, melasma, or post inflammatory hyperpigmentation. Approximately 55% of subjects reported marked to very significant improvement at one and three months post final treatment. Blinded assessment of photography of 20 subjects revealed an average of moderate improvement at one-month follow up and mild to moderate improvement at three months. Average subject pain score was 3.4/10 during treatment. Favorable outcomes were demonstrated using the low energy low density, non-ablative fractional 1,927-nm laser in facial resurfacing for photodamage, melasma, and post inflammatory hyperpigmentation. Results were maintained at the 3-month follow up, as demonstrated by investigator and subject assessments, as well as blinded evaluations by three independent dermatologists utilizing photographs obtained from a standardized facial imaging device.

  10. Organic nanostructures on silicon, created with semitransparent polystyrene spheres and 248 nm laser pulses

    International Nuclear Information System (INIS)

    Rothe, Erhard W; Manke, Charles W; Piparia, Reema; Baird, Ronald J

    2008-01-01

    Arrays of nanostructures are made starting with a template of close-packed, polystyrene spheres on a silicon surface. The spheres are either 1.091 or 2.99 μm in diameter (d) and are of polystyrene (PS). They are irradiated with a pulse of either 308 or 248 nm light to which they are transparent and semitransparent, respectively. A transparent sphere with d = 1.091 μm diameter concentrates incident light onto a small substrate area. As has been previously reported, that creates silicon nanobumps that rise from circular craters. At 248 nm and d = 2.99 μm, the light energy is mainly absorbed, destroys the sphere, and leaves a shrunken mass (typically about 500 nm wide and 100 nm high) of organic material that is probably polystyrene and its thermal degradation products. At 248 nm and d = 1.091 μm, the residual organic structures are on the order of 300 nm wide and 100 nm high. A distinctive feature is that these organic structures are connected by filaments that are on the order of 50 nm wide and 10 nm high. Filaments form because the close-packed PS spheres expand into each other during the early part of the laser pulse, and then, as the main structures shrink, their viscoelasticity leads to threads between them. Our results with 248 nm and d = 1.091 μm differ from those described by Huang et al with 248 nm and d = 1.0 μm. Future studies might include the further effect of wavelength and fluence upon the process as well the use of other materials and the replacement of nanospheres by other focusing shapes, such as ellipsoids or rods

  11. 40 CFR 23.11 - Holidays.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Holidays. 23.11 Section 23.11... STATUTES § 23.11 Holidays. If the date determined under §§ 23.2 to 23.10 falls on a Federal holiday, then... that is not a Federal holiday. ...

  12. Dose and batch-dependent hepatobiliary toxicity of 10 nm silver nanoparticles

    Directory of Open Access Journals (Sweden)

    Marcella De Maglie

    2015-07-01

    Full Text Available Silver nanoparticles (AgNPs are widely used because of their antimicrobial properties in medical devices and in a variety of consumer products. The extensive use of AgNPs raises concerns about their potential toxicity, although it is still difficult to draw definite conclusions about their toxicity based on published data. Our preliminary studies performed to compare the effect of the AgNPs size (10-40-100 nm on toxicity, demonstrated that the smallest AgNPs determine the most severe toxicological effects. In order to best investigate the impact of physicochemical characteristics of 10 nm AgNPs on toxicity, we compare three different batches of 10 nm AgNPs slightly different in size distribution (Batch A: 8.8±1.7 nm; Batch B: 9.4±1.7 nm; Batch C: 10.0±1.8 nm. Mice were intravenously treated with two doses (5 and 10 mg/kg of the 3 AgNPs. 24 hours after the treatment, mice were euthanized and underwent complete necropsy. Tissues were collected for histopathological examination and total silver content was determined in tissues by inductively coupled plasma mass spectrometry (ICP-MS. All batches induced severe hepatobiliary lesions, i.e. marked hepatocellular necrosis and massive hemorrhage of the gall bladder. The toxicity was dose-dependent and interestingly, the toxic effects were more severe in mice treated with batches A and B that contained smaller AgNPs. Since the total silver mass concentration was similar, the observed batch-dependent toxicity suggest that even subtle differences in size may contribute to relevant changes in the toxicological outcomes, confirming the fundamental involvement of physicochemical features with respect to toxicity.

  13. Continuous-wave and passively Q-switched Nd:YVO4 laser at 1085 nm

    Science.gov (United States)

    Lin, Hongyi; Liu, Hong; Huang, Xiaohua; Zhang, Jiyan

    2017-11-01

    An admirable and efficient Nd:YVO4 laser at 1085 nm is demonstrated with a compact 35 mm plano-plano cavity. A chosen narrow bandpass filter with high-transmittance (HT) coating at 1064 nm (T=96%) and optimized part-reflection (PR) coating at 1085 nm (T=15%) is used as the output coupler. In the continuous-wave (CW) regime, the maximum output power reaches 3110 mW at the pump power of 11.41 W. Based on a Cr:YAG crystal with initial-transmittance of 91%, the first passively Q-switched Nd:YVO4 laser at 1085 nm is achieved. When the pump power is changed from the threshold of 4.50 to 6.08 W, the dual-wavelength lines at 1064 and 1085 nm are generated simultaneously. However, at the pump power of above 6.08 W, the single-wavelength line at 1085 nm is achieved. The largest output power, the highest peak power, and the narrowest pulse width are 1615 mW, 878 W and 26.2 ns, respectively.

  14. EST Table: NM_001043366 [KAIKOcDNA[Archive

    Lifescience Database Archive (English)

    Full Text Available NM_001043366 Sap-r 10/09/29 98 %/961 aa ref|NP_001036831.1| saposin-related [Bombyx... gnl|Amel|GB16561-PA 10/09/10 42 %/808 aa gi|91077504|ref|XP_966852.1| PREDICTED: similar to saposin isoform 1 [Tribolium castaneum] FS791050 ...

  15. ILT optimization of EUV masks for sub-7nm lithography

    Science.gov (United States)

    Hooker, Kevin; Kuechler, Bernd; Kazarian, Aram; Xiao, Guangming; Lucas, Kevin

    2017-06-01

    The 5nm and 7nm technology nodes will continue recent scaling trends and will deliver significantly smaller minimum features, standard cell areas and SRAM cell areas vs. the 10nm node. There are tremendous economic pressures to shrink each subsequent technology, though in a cost-effective and performance enhancing manner. IC manufacturers are eagerly awaiting EUV so that they can more aggressively shrink their technology than they could by using complicated MPT. The current 0.33NA EUV tools and processes also have their patterning limitations. EUV scanner lenses, scanner sources, masks and resists are all relatively immature compared to the current lithography manufacturing baseline of 193i. For example, lens aberrations are currently several times larger (as a function of wavelength) in EUV scanners than for 193i scanners. Robustly patterning 16nm L/S fully random logic metal patterns and 40nm pitch random logic rectangular contacts with 0.33NA EUV are tough challenges that will benefit from advanced OPC/RET. For example, if an IC manufacturer can push single exposure device layer resolution 10% tighter using improved ILT to avoid using DPT, there will be a significant cost and process complexity benefit to doing so. ILT is well known to have considerable benefits in finding flexible 193i mask pattern solutions to improve process window, improve 2D CD control, improve resolution in low K1 lithography regime and help to delay the introduction of DPT. However, ILT has not previously been applied to EUV lithography. In this paper, we report on new developments which extend ILT method to EUV lithography and we characterize the benefits seen vs. traditional EUV OPC/RET methods.

  16. Treatment of oral lichen planus using 308-nm excimer laser.

    Science.gov (United States)

    Liu, Wei-Bing; Sun, Li-Wei; Yang, Hua; Wang, Yan-Fei

    2017-09-01

    Oral lichen planus (OLP) is a chronic inflammatory disease, has prolonged courses, repeated attacks and resistance to treatment. The traditional narrow spectrum UVB treatment has an established efficacy on skin lichen planus, and high safety. However, most of ultraviolet phototherapy devices have a huge volume, thereby cannot be used in the treatment of OLP. Lymphocytic infiltration is evident in the lesions of lichen planus, and the direct irradiation of 308-nm excimer laser can induce apoptosis of the T lymphocytes in skin lesions, thereby has a unique therapeutic effect on the diseases involving T lymphocytes. This study aims to investigate the efficacy of 308-nm excimer laser in the treatment of OLP. A total of six OLP patients were enrolled into this study, and further pathological diagnosis was conducted, then 308-nm excimer laser was used in the treatment. The efficacy of 308-nm excimer laser in the treatment of OLP was satisfactory. The clinical symptoms of five patients were significantly improved. In two patients, the erosion surface based on congestion and the surrounding white spots completely disappeared, and clinical recovery was achieved. Three patients achieved partial remission, that is, the erosion surface healed, congestion and white spot area shrunk by more than 1/2 of the primary skin lesions. In the remaining one patient, the erosion surface had not completely healed after treatment, and congestion and white spot area shrunk by less than 1/2 of the primary skin lesions. Only one patients had developed mild pain during the treatment, and this symptom alleviated by itself. The 308-nm excimer laser therapy can serve as a safe and effective treatment for OLP. © 2017 Wiley Periodicals, Inc.

  17. Diode-pumped passively mode-locked composite crystal Nd:Lu0.15Y0.85VO4 laser at 1342.2 nm

    International Nuclear Information System (INIS)

    Qiao, Wenchao; Zhao, Shengzhi; Li, Guiqiu; Yang, Kejian; Li, Tao; Zhao, Jia; Zhao, Bin

    2015-01-01

    A diode-pumped mode-locked Nd:Lu 0.15 Y 0.85 VO 4 laser running at 1342.2 nm is firstly demonstrated with a semiconductor saturable absorber mirror (SESAM). Stable mode-locking pulses with the pulse-duration of 15.2 ps and the repetition rate of 32.8 MHz have been achieved. With a pumping power of 7.1 W, an output power of 786 mW was obtained, corresponding to an optical conversion efficiency of 11%. A maximum mode-locked pulse energy was estimated to be 23.96 nJ with a peak power of 1.58 kW. (paper)

  18. Synthesis and hydrogen storage of La23Nd7.8Ti1.1Ni33.9Co32.9Al0.65 alloys

    Directory of Open Access Journals (Sweden)

    Priyanka Meena

    2018-04-01

    Full Text Available The present work investigates structural and hydrogen storage properties of first time synthesized La23Nd7.8Ti1.1Ni33.9Co32.9Al0.65 alloy by arc melting process and ball milled to get it in nano structure form. XRD analysis of as-prepared alloy showed single phased hexagonal LaNi5-type structure with 52 nm average particle size, which reduces to about 31 nm after hydrogenations. Morphological studies by SEM were undertaken to investigate the effect of hydrogenation of nanostructured alloy. EDX analysis confirmed elemental composition of the as-prepared alloy. Activation energy for hydrogen desorption was studied using TGA analysis and found to be −76.86 kJ/mol. Hydrogenation/dehydrogenation reactions and absorption kinetics were measured at temperature 100 °C. The equilibrium plateau pressure was determined to be 2 bar at 100 °C giving hydrogen storage capacity of about 2.1 wt%. Keywords: Hydrogen storage, La23Nd7.8Ti1.1Ni33.9Co32.9Al0.65 alloy, SEM, EDS, TGA, Hydrogenation/dehydrogenation

  19. Efficient 525 nm laser generation in single or double resonant cavity

    Science.gov (United States)

    Liu, Shilong; Han, Zhenhai; Liu, Shikai; Li, Yinhai; Zhou, Zhiyuan; Shi, Baosen

    2018-03-01

    This paper reports the results of a study into highly efficient sum frequency generation from 792 and 1556 nm wavelength light to 525 nm wavelength light using either a single or double resonant ring cavity based on a periodically poled potassium titanyl phosphate crystal (PPKTP). By optimizing the cavity's parameters, the maximum power achieved for the resultant 525 nm laser was 263 and 373 mW for the single and double resonant cavity, respectively. The corresponding quantum conversion efficiencies were 8 and 77% for converting 1556 nm photons to 525 nm photons with the single and double resonant cavity, respectively. The measured intra-cavity single pass conversion efficiency for both configurations was about 5%. The performances of the sum frequency generation in these two configurations was studied and compared in detail. This work will provide guidelines for optimizing the generation of sum frequency generated laser light for a variety of configurations. The high conversion efficiency achieved in this work will help pave the way for frequency up-conversion of non-classical quantum states, such as the squeezed vacuum and single photon states. The proposed green laser source will be used in our future experiments, which includes a plan to generate two-color entangled photon pairs and achieve the frequency down-conversion of single photons carrying orbital angular momentum.

  20. 980nm laser for difficult-to-treat basal cell carcinoma

    Science.gov (United States)

    Derjabo, A. D.; Cema, I.; Lihacova, I.; Derjabo, L.

    2013-06-01

    Begin basal cell carcinoma (BCC) is most common skin cancer over the world. There are around 20 modalities for BCC treatment. Laser surgery is uncommon option. We demonstrate our long term follow up results. Aim: To evaluate long term efficacy of a 980nm diode laser for the difficult-to-treat basal cell carcinoma. Materials and Methods: 167 patients with 173 basal cell carcinoma on the nose were treated with a 980 nm diode laser from May 1999 till May 2005 at Latvian Oncology center. All tumors were morphologically confirmed. 156 patients were followed for more than 5 years. Results: The lowest recurrence rate was observed in cases of superficial BCC, diameterConclusions: 980 nm diode laser is useful tool in dermatology with high long term efficacy, good acceptance by the patients and good cosmetics results.

  1. По зимнему бездорожью на полном приводе / Велиматти Хонканен, Яри Питкаярви и Ярмо Сукава

    Index Scriptorium Estoniae

    Хонканен, Велиматти

    2003-01-01

    Audi A4 1,8 T Quattro, BMW 325Xi, Honda HR-V 1,6i, Jaguar X-Type 3,0 V6, Mercedes-Benz E 320 4matic, Renault Scenic RX4 2,0, Škoda Octavia Combi 2,0WD, Subaru Impreza 2,0 GX, Suzuki Liana 1,6 4WD, Volvo S60 AWD

  2. Building blocks for future detectors: Silicon test masses and 1550 nm laser light

    International Nuclear Information System (INIS)

    Schnabel, R; Britzger, M; Burmeister, O; Danzmann, K; Duck, J; Eberle, T; Friedrich, D; Luck, H; Mehmet, M; Steinlechner, S; Willke, B; Brueckner, F; Nawrodt, R

    2010-01-01

    Current interferometric gravitational wave detectors use the combination of quasi-monochromatic, continuous-wave laser light at 1064 nm and fused silica test masses at room temperature. Detectors of the third generation, such as the Einstein-Telescope, will involve a considerable sensitivity increase. The combination of 1550 nm laser radiation and crystalline silicon test masses at low temperatures might be important ingredients in order to achieve the sensitivity goal. Here we compare some properties of the fused silica and silicon test mass materials relevant for decreasing the thermal noise in future detectors as well as the recent technology achievements in the preparation of laser radiation at 1064 nm and 1550 nm relevant for decreasing the quantum noise. We conclude that silicon test masses and 1550 nm laser light have the potential to form the future building blocks of gravitational wave detection.

  3. The cystic fibrosis transmembrane recruiter the alter ego of CFTR as a multi-kinase anchor.

    Science.gov (United States)

    Mehta, Anil

    2007-11-01

    This review focuses on a newly discovered interaction between protein kinases involved in cellular energetics, a process that may be disturbed in cystic fibrosis for unknown reasons. I propose a new model where kinase-mediated cellular transmission of energy provides mechanistic insight to a latent role of the cystic fibrosis transmembrane conductance regulator (CFTR). I suggest that CFTR acts as a multi-kinase recruiter to the apical epithelial membrane. My group finds that, in the cytosol, two protein kinases involved in cell energy homeostasis, nucleoside diphosphate kinase (NDPK) and AMP-activated kinase (AMPK), bind one another. Preliminary data suggest that both can also bind CFTR (function unclear). The disrupted role of this CFTR-kinase complex as 'membrane transmitter to the cell' is proposed as an alternative paradigm to the conventional ion transport mediated and CFTR/chloride-centric view of cystic fibrosis pathogenesis. Chloride remains important, but instead, chloride-induced control of the phosphohistidine content of one kinase component (NDPK, via a multi-kinase complex that also includes a third kinase, CK2; formerly casein kinase 2). I suggest that this complex provides the necessary near-equilibrium conditions needed for efficient transmission of phosphate energy to proteins controlling cellular energetics. Crucially, a new role for CFTR as a kinase controller is proposed with ionic concentration acting as a signal. The model posits a regulatory control relay for energy sensing involving a cascade of protein kinases bound to CFTR.

  4. Compact gain saturated plasma based X-ray lasers down to 6.9nm

    Science.gov (United States)

    Rocca, Jorge; Wang, Y.; Wang, S.; Rockwood, A.; Berrill, M.; Shlyaptsev, V.

    2017-10-01

    Plasma based soft x-ray amplifiers allow many experiments requiring bright, high energy soft x-ray laser pulses to be conducted in compact facilities. We have extended the wavelength of compact gain saturated x-ray lasers to 6.89 nm in a Ni-like Gd plasma generated by a Ti:Sa laser. Gain saturated laser operation was also obtained at 7.36 nm in Ni-like Sm. Isolectronic scaling and optimization of laser pre-pulse duration allowed us to also observe strong lasing at 6.6 nm and 6.1 nm in Ni-like Tb, and amplification at 6.4 nm and 5.89 nm in Ni-like Dy. The results were obtained by transient laser heating of solid targets with traveling wave excitation at progressively increased gracing incidence angles. We show that the optimum pump angle of incidence for collisional Ni-like lasers increases linearly with atomic number from Z =42 to Z =66, reaching 43 degrees for Ni-like Dy, in good agreement with hydrodynamic/atomic physics simulations. These results will enable single-shot nano-scale imaging and other application of sub-7 nm lasers to be performed at compact facilities. Work supported by Grant DE-FG02-4ER15592 of the Department of Energy, Office of Science, and by the National Science Foundation Grant ECCS 1509925.

  5. Combination of 595-nm pulsed dye laser, long-pulsed 755-nm alexandrite laser, and microdermabrasion treatment for keratosis pilaris: retrospective analysis of 26 Korean patients.

    Science.gov (United States)

    Lee, Sang Ju; Choi, Min Ju; Zheng, Zhenlong; Chung, Won Soon; Kim, Young Koo; Cho, Sung Bin

    2013-06-01

    Keratosis pilaris (KP) has beenpresented as small keratotic follicular papules with or without surrounding erythema. Various treatments with laser or light therapy have been used for the management of KP with various clinical outcomes. In the present study, we investigated the efficacy and safety of a combination therapy for KP. A total of 29 anatomical sites with KP in 26 patients were treated using a 595-nm pulsed dye laser (PDL) with nonpurpuragenic fluences, a long-pulsed 755-nm alexandrite laser, and microdermabrasion. Clinical improvement was assessed by comparing preand posttreatment clinical photographs and patient satisfaction rates. Evaluation of the clinical results three months after the treatments showed that 12 of the 29 anatomical sites (41.4%) demonstrated Grade 3 clinical improvement, ten (34.5%) had Grade 2 clinical improvement, four (13.8%) showed Grade 1 improvement, and three (10.3%) showed Grade 4 improvement. We observed that KP lesions improved not only in erythema and skin texture, but also in brownish dyschromias. Potential adverse events were not observed, except prolonged posttherapy scaling. Our observations demonstrate that combination therapy using a 595-nm PDL, a long-pulsed 755-nm alexandrite laser, and microdermabrasion can have a positive therapeutic effect on KP.

  6. Improvement of optical damage in specialty fiber at 266 nm wavelength

    Science.gov (United States)

    Tobisch, T.; Ohlmeyer, H.; Zimmermann, H.; Prein, S.; Kirchhof, J.; Unger, S.; Belz, M.; Klein, K.-F.

    2014-02-01

    Improved multimode UV-fibers with core diameters ranging from 70 to 600 μm diameter have been manufactured based on novel preform modifications and fiber processing techniques. Only E'-centers at 214 nm and NBOHC at 260 nm are generated in these fibers. A new generation of inexpensive laser-systems have entered the market and generated a multitude of new and attractive applications in the bio-life science, chemical and material processing field. However, for example pulsed 355 nm Nd:YAG lasers generate significant UV-damages in commercially available fibers. For lower wavelengths, no results on suitable multi-mode or low-mode fibers with high UV resistance at 266 nm wavelength (pulsed 4th harmonic Nd:YAG laser) have been published. In this report, double-clad fibers with 70 μm or 100 μm core diameter and a large claddingto- core ratio will be recommended. Laser-induced UV-damages will be compared between these new fiber type and traditional UV fibers with similar core sizes. Finally, experimental results will be cross compared against broadband cw deuterium lamp damage standards.

  7. Optical track width measurements below 100 nm using artificial neural networks

    Science.gov (United States)

    Smith, R. J.; See, C. W.; Somekh, M. G.; Yacoot, A.; Choi, E.

    2005-12-01

    This paper discusses the feasibility of using artificial neural networks (ANNs), together with a high precision scanning optical profiler, to measure very fine track widths that are considerably below the conventional diffraction limit of a conventional optical microscope. The ANN is trained using optical profiles obtained from tracks of known widths, the network is then assessed by applying it to test profiles. The optical profiler is an ultra-stable common path scanning interferometer, which provides extremely precise surface measurements. Preliminary results, obtained with a 0.3 NA objective lens and a laser wavelength of 633 nm, show that the system is capable of measuring a 50 nm track width, with a standard deviation less than 4 nm.

  8. High-Power Yb-Doped Solid-Core Photonic Bandgap Fiber Amplifier at 1150-1200nm

    DEFF Research Database (Denmark)

    Maruyama, H.; Shirakawa, A.; Ueda, K.

    2008-01-01

    Solid-core photonic-bandgap fiber amplification at the long-wavelength edge of ytterbium band is reported. A 32W output at 1156nm with a 66% slope efficiency and 9.1W output at 1178nm were succesfully obtained.......Solid-core photonic-bandgap fiber amplification at the long-wavelength edge of ytterbium band is reported. A 32W output at 1156nm with a 66% slope efficiency and 9.1W output at 1178nm were succesfully obtained....

  9. In Vitro Study of Dentin Hypersensitivity Treated by 980-nm Diode Laser.

    Science.gov (United States)

    Liu, Ying; Gao, Jie; Gao, Yan; Xu, Shuaimei; Zhan, Xueling; Wu, Buling

    2013-01-01

    To investigate the ultrastructural changes of dentin irradiated with 980-nm diode laser under different parameters and to observe the morphological alterations of odontoblasts and pulp tissue to determine the safety parameters of 980-nm diode laser in the treatment of dentin hypersensitivity (DH). Twenty extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into four areas and was irradiated by 980-nm diode laser under different parameters: Group A: control group, 0 J/cm(2); Group B: 2 W/CW (continuous mode), 166 J/cm(2); Group C: 3W/CW, 250 J/cm(2); and Group D: 4W/CW, 333 J/cm(2). Ten additional extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into two areas and was irradiated by 980-nm diode laser: Group E: control group, 0 J/cm(2); and Group F: 2.0 W/CW, 166 J/cm(2). The morphological alterations of the dentin surfaces and odontoblasts were examined with scanning electron microscopy (SEM), and the morphological alterations of the dental pulp tissue irradiated by laser were observed with an upright microscope. The study demonstrated that dentinal tubules can be entirely blocked after irradiation by 980-nm diode laser, regardless of the parameter setting. Diode laser with settings of 2.0 W and 980-nm sealed exposed dentin tubules effectively, and no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. Irradiation with 980-nm diode laser could be effective for routine clinical treatment of DH, and 2.0W/CW (166 J/cm(2)) was a suitable energy parameter due to its rapid sealing of the exposed dentin tubules and its safety to the odontoblasts and pulp tissue.

  10. In Vitro Study of Dentin Hypersensitivity Treated by 980-nm Diode Laser

    Science.gov (United States)

    Liu, Ying; Gao, Jie; Gao, Yan; XU, Shuaimei; Zhan, Xueling; Wu, Buling

    2013-01-01

    Introduction: To investigate the ultrastructural changes of dentin irradiated with 980-nm diode laser under different parameters and to observe the morphological alterations of odontoblasts and pulp tissue to determine the safety parameters of 980-nm diode laser in the treatment of dentin hypersensitivity (DH). Methods: Twenty extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into four areas and was irradiated by 980-nm diode laser under different parameters: Group A: control group, 0 J/cm2; Group B: 2 W/CW (continuous mode), 166 J/cm2; Group C: 3W/CW, 250 J/cm2; and Group D: 4W/CW, 333 J/cm2. Ten additional extracted human third molars were selected to prepare dentin discs. Each dentin disc was divided into two areas and was irradiated by 980-nm diode laser: Group E: control group, 0 J/cm2; and Group F: 2.0 W/CW, 166 J/cm2. The morphological alterations of the dentin surfaces and odontoblasts were examined with scanning electron microscopy (SEM), and the morphological alterations of the dental pulp tissue irradiated by laser were observed with an upright microscope. Results: The study demonstrated that dentinal tubules can be entirely blocked after irradiation by 980-nm diode laser, regardless of the parameter setting. Diode laser with settings of 2.0 W and 980-nm sealed exposed dentin tubules effectively, and no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. Conclusions: Irradiation with 980-nm diode laser could be effective for routine clinical treatment of DH, and 2.0W/CW (166 J/cm2) was a suitable energy parameter due to its rapid sealing of the exposed dentin tubules and its safety to the odontoblasts and pulp tissue. PMID:25606318

  11. Investigations of a Dual Seeded 1178 nm Raman Laser System

    Science.gov (United States)

    2016-01-14

    was obtained by Raman amplification of a distributed feedback diode laser in a variably strained polarization- maintaining fiber with a record-high...Calia, D.B., “50W CW visible laser source at 589 nm obtained via frequency doubling of three coherently combined narrow-band Raman fiber amplifiers...AFRL-RD-PS- TP-2016-0009 AFRL-RD-PS- TP-2016-0009 INVESTIGATIONS OF A DUAL SEEDED 1178 NM RAMAN LASER SYSTEM Leanne Henry, et al. 14 January

  12. The dynamics of femtosecond pulsed laser removal of 20 nm Ni films from an interface

    Energy Technology Data Exchange (ETDEWEB)

    Schrider, Keegan J.; Yalisove, Steven M. [Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109 (United States); Torralva, Ben [Department of Atmospheric, Oceanic, and Space Sciences, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2015-09-21

    The dynamics of femtosecond laser removal of 20 nm Ni films on glass substrates was studied using time-resolved pump-probe microscopy. 20 nm thin films exhibit removal at two distinct threshold fluences, removal of the top 7 nm of Ni above 0.14 J/cm{sup 2}, and removal of the entire 20 nm film above 0.36 J/cm{sup 2}. Previous work shows the top 7 nm is removed through liquid spallation, after irradiation the Ni melts and rapidly expands leading to tensile stress and cavitation within the Ni film. This work shows that above 0.36 J/cm{sup 2} the 20 nm film is removed in two distinct layers, 7 nm and 13 nm thick. The top 7 nm layer reaches a speed 500% faster than the bottom 13 nm layer at the same absorbed fluence, 500–2000 m/s and 300–700 m/s in the fluence ranges studied. Significantly different velocities for the top 7 nm layer and bottom 13 nm layer indicate removal from an interface occurs by a different physical mechanism. The method of measuring film displacement from the development of Newton's rings was refined so it could be shown that the 13 nm layer separates from the substrate within 70 ps and accelerates to its final velocity within several hundred picoseconds. We propose that removal of the bottom 13 nm is consistent with heterogeneous nucleation and growth of vapor at the Ni-glass interface, but that the rapid separation and acceleration of the 13 nm layer from the Ni-glass interface requires consideration of exotic phases of Ni after excitation.

  13. High Production of 2,3-Butanediol (2,3-BD by Raoultella ornithinolytica B6 via Optimizing Fermentation Conditions and Overexpressing 2,3-BD Synthesis Genes.

    Directory of Open Access Journals (Sweden)

    Taeyeon Kim

    Full Text Available Biological production of 2,3-butandiol (2,3-BD has received great attention as an alternative to the petroleum-based 2,3-BD production. In this study, a high production of 2,3-BD in fed-batch fermentation was investigated with a newly isolated bacterium designated as Raoultella ornithinolytica B6. The isolate produced 2,3-BD as the main product using hexoses (glucose, galactose, and fructose, pentose (xylose and disaccharide (sucrose. The effects of temperature, pH-control schemes, and agitation speeds on 2,3-BD production were explored to optimize the fermentation conditions. Notably, cell growth and 2,3-BD production by R. ornithinolytica B6 were higher at 25°C than at 30°C. When three pH control schemes (no pH control, pH control at 7, and pH control at 5.5 after the pH was decreased to 5.5 during fermentation were tested, the best 2,3-BD titer and productivity along with reduced by-product formation were achieved with pH control at 5.5. Among different agitation speeds (300, 400, and 500 rpm, the optimum agitation speed was 400 rpm with 2,3-BD titer of 68.27 g/L, but acetic acid was accumulated up to 23.32 g/L. Further enhancement of the 2,3-BD titer (112.19 g/L, yield (0.38 g/g, and productivity (1.35 g/L/h as well as a significant reduction of acetic acid accumulation (9.71 g/L was achieved by the overexpression of homologous budABC genes, the 2,3-BD-synthesis genes involved in the conversion of pyruvate to 2,3-BD. This is the first report presenting a high 2,3-BD production by R.ornithinolytica which has attracted little attention with respect to 2,3-BD production, extending the microbial spectrum of 2,3-BD producers.

  14. A novel double patterning approach for 30nm dense holes

    Science.gov (United States)

    Hsu, Dennis Shu-Hao; Wang, Walter; Hsieh, Wei-Hsien; Huang, Chun-Yen; Wu, Wen-Bin; Shih, Chiang-Lin; Shih, Steven

    2011-04-01

    Double Patterning Technology (DPT) was commonly accepted as the major workhorse beyond water immersion lithography for sub-38nm half-pitch line patterning before the EUV production. For dense hole patterning, classical DPT employs self-aligned spacer deposition and uses the intersection of horizontal and vertical lines to define the desired hole patterns. However, the increase in manufacturing cost and process complexity is tremendous. Several innovative approaches have been proposed and experimented to address the manufacturing and technical challenges. A novel process of double patterned pillars combined image reverse will be proposed for the realization of low cost dense holes in 30nm node DRAM. The nature of pillar formation lithography provides much better optical contrast compared to the counterpart hole patterning with similar CD requirements. By the utilization of a reliable freezing process, double patterned pillars can be readily implemented. A novel image reverse process at the last stage defines the hole patterns with high fidelity. In this paper, several freezing processes for the construction of the double patterned pillars were tested and compared, and 30nm double patterning pillars were demonstrated successfully. A variety of different image reverse processes will be investigated and discussed for their pros and cons. An economic approach with the optimized lithography performance will be proposed for the application of 30nm DRAM node.

  15. In vivo retinal optical coherence tomography at 1030 nm with enhanced penetration into the choroid

    Science.gov (United States)

    Unterhuber, A.; Povazay, B.; Hermann, B.; Sattmann, H.; Michels, S.; Sacu, S.; Ahlers, C.; Scholda, C.; Chavez-Pirson, A.; Schmidt-Erfurth, U.; Fercher, Adolf F.; Drexler, W.

    2005-08-01

    In vivo retinal imaging with ~ 8 μm axial resolution at 1030 nm is demonstrated for the first time, enabling enhanced penetration into the choroid. A new high power, broad bandwidth light source based on amplified spontaneous emission (NP Photonics, λc = 1030 nm, Δλ= 50 nm, Pout = 25 mW) has been interfaced to a time domain ophthalmic OCT system. In vivo retinal OCT tomograms performed at 800 nm are compared to those achieved at 1030 nm. Retinal OCT at longer wavelengths, e.g. 1030 nm significantly improves the visualization of the retinal pigment epithelium/choriocapillaris/choroid interface and might therefore provide new insight into choroidal/choriocapillary changes in age-related macular degeneration and other diseases of the retinal pigment epithelium (RPE)-choroid complex. 1030 nm OCT could also become a valuable tool in monitoring treatment effects on the choroids as in Verteporfin therapy.

  16. Continuous-wave single-frequency laser with dual wavelength at 1064 and 532 nm.

    Science.gov (United States)

    Zhang, Chenwei; Lu, Huadong; Yin, Qiwei; Su, Jing

    2014-10-01

    A continuous-wave high-power single-frequency laser with dual-wavelength output at 1064 and 532 nm is presented. The dependencies of the output power on the transmission of the output coupler and the phase-matching temperature of the LiB(3)O(5) (LBO) crystal are studied. An output coupler with transmission of 19% is used, and the temperature of LBO is controlled to the optimal phase-matching temperature of 422 K; measured maximal output powers of 33.7 W at 1064 nm and of 1.13 W at 532 nm are obtained with optical-optical conversion efficiency of 45.6%. The laser can be single-frequency operated stably and mode-hop-free, and the measured frequency drift is less than 15 MHz in 1 min. The measured Mx2 and My2 for the 1064 nm laser are 1.06 and 1.09, respectively. The measured Mx2 and My2 for the 532 nm laser are 1.12 and 1.11, respectively.

  17. Exploration of BEOL line-space patterning options at 12 nm half-pitch and below

    Science.gov (United States)

    Decoster, S.; Lazzarino, F.; Petersen Barbosa Lima, L.; Li, W.; Versluijs, J.; Halder, S.; Mallik, A.; Murdoch, G.

    2018-03-01

    While the semiconductor industry is almost ready for high-volume manufacturing of the 7 nm technology node, research centers are defining and troubleshooting the patterning options for the 5 nm technology node (N5) and below. The target dimension for imec's N5 BEOL applications is 20-24 nm Metal Pitch (MP), which requires Self-Aligned multiple (Double/Quadruple/Octuple) Patterning approaches (SAxP) in combination with EUV or immersion lithography at 193 nm. There are numerous technical challenges to enable gratings at the hard mask level such as good uniformity across wafer, low line edge/width roughness (LER/LWR), large process window, and all of this at low cost. An even greater challenge is to transfer these gratings into the dielectric material at such critical dimensions, where increased line edge roughness, line wiggling and even pattern collapse can be expected for materials with small mechanical stability such as highly porous low-k dielectrics. In this work we first compare three different patterning options for 12 nm half-pitch gratings at the hard mask level: EUV-based SADP and 193i-based SAQP and SAOP. This comparison will be based on process window, line edge/width roughness and cost. Next, the transfer of 12 nm line/space gratings in the dielectric material is discussed and presented. The LER of the dielectric lines is investigated as a function of the dielectric material, the trench depth, and the stress in the sacrificial hard mask. Finally, we elaborate on the different options to enable scaling down from 24 nm MP to 16 nm MP, and demonstrate 8 nm line/space gratings with 193i-based SAOP.

  18. Writable and erasable PPV medium by irradiation at 365 nm

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, Hiroyuki [Photonics Research Institutes, National Institute of Advanced Industrial Science and Technology, 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577 (Japan)], E-mail: h-mochizuki@aist.go.jp; Mizokuro, Toshiko; Tanigaki, Nobutaka; Hiraga, Takashi [Photonics Research Institutes, National Institute of Advanced Industrial Science and Technology, 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577 (Japan)

    2008-03-03

    Dopings of vaporized cis-1,2-dicyano-1,2-bis(2,4,5-trimethyl-3-thienyl) ethane (CMTE) into poly(methyl methacrylate) (PMMA), polystyrene, and polycarbonate were performed by a vacuum process, and the doping behaviors of CMTE were evaluated. Among the matrix polymers, PMMA was dispersed CMTE densely in its surface region. By using the CMTE-doped PMMA, we could fabricate a novel rewritable medium: a multi-layered film was prepared from over-coating of CMTE-doped PMMA onto poly(p-phenylene vinylene) (PPV) film, which set on a transparent substrate. Image storage could be performed upon irradiation at 365 nm at the side of CMTE/PMMA layer: color of the irradiated area changed a light yellow to a red due to photo-isomerization of CMTE. Next, upon irradiation at 365 nm at the side of the transparent substrate, PPV emitted a green fluorescence at around 530 nm, and the CMTE absorbed the emission from PPV causing image-erasure based on back-isomerization of CMTE.

  19. Photoacoustic imaging at 1064nm wavelength with exogenous contrast agents

    Science.gov (United States)

    Upputuri, Paul Kumar; Jiang, Yuyan; Pu, Kanyi; Pramanik, Manojit

    2018-02-01

    Photoacoustic (PA) imaging is a promising imaging modality for both preclinical research and clinical practices. Laser wavelengths in the first near infrared window (NIR-I, 650-950 nm) have been widely used for photoacoustic imaging. As compared with NIR-I window, scattering of photons by biological tissues is largely reduced in the second NIR (NIR-II) window, leading to enhanced imaging fidelity. However, the lack of biocompatible NIR-II absorbing exogenous agents prevented the use of this window for in vivo imaging. In recent years, few studies have been reported on photoacoustic imaging in NIR-II window using exogenous contrast agents. In this work, we discuss the recent work on PA imaging using 1064 nm wavelength, the fundamental of Nd:YAG laser, as an excitation wavelength. The PA imaging at 1064 nm is advantageous because of the low and homogeneous signal from tissue background, enabling high contrast in PA imaging when NIR-II absorbing contrast agents are employed.

  20. Efficacy of antimicrobial 405 nm blue-light for inactivation of airborne bacteria

    Science.gov (United States)

    Dougall, Laura R.; Anderson, John G.; Timoshkin, Igor V.; MacGregor, Scott J.; Maclean, Michelle

    2018-02-01

    Airborne transmission of infectious organisms is a considerable concern within the healthcare environment. A number of novel methods for `whole room' decontamination, including antimicrobial 405 nm blue light, are being developed. To date, research has focused on its effects against surface-deposited contamination; however, it is important to also establish its efficacy against airborne bacteria. This study demonstrates evidence of the dose-response kinetics of airborne bacterial contamination when exposed to 405 nm light and compares bacterial susceptibility when exposed in three different media: air, liquid and surfaces. Bacterial aerosols of Staphylococcus epidermidis, generated using a 6-Jet Collison nebulizer, were introduced into an aerosol suspension chamber. Aerosolized bacteria were exposed to increasing doses of 405 nm light, and air samples were extracted from the chamber using a BioSampler liquid impinger, with viability analysed using pour-plate culture. Results have demonstrated successful aerosol inactivation, with a 99.1% reduction achieved with a 30 minute exposure to high irradiance (22 mWcm-2) 405 nm light (P=0.001). Comparison to liquid and surface exposures proved bacteria to be 3-4 times more susceptible to 405 nm light inactivation when in aerosol form. Overall, results have provided fundamental evidence of the susceptibility of bacterial aerosols to antimicrobial 405 nm light treatment, which offers benefits in terms of increased safety for human exposure, and eradication of microbes regardless of antibiotic resistance. Such benefits provide advantages for a number of applications including `whole room' environmental decontamination, in which reducing levels of airborne bacteria should reduce the number of infections arising from airborne contamination.

  1. EUV beam splitter for use in the wavelength region around 6 nm

    International Nuclear Information System (INIS)

    Takenaka, Hisataka; Ichimaru, Satoshi; Gullikson, E.M.

    2005-01-01

    Extreme ultraviolet (EUV) beam splitters for use at a wavelength of around 6 nm were fabricated. The designs were optimized for Cr/C multilayers and incident angles of 45 deg. and 80 deg. . Measurements revealed the reflectivity of a Cr/C beam splitter to be 3.3% and the transmittance to be 5.6% at a wavelength of 6.36 nm and an incident angle of 45 deg. . The reflectivity of a Cr/C beam splitter was 5.8% and the transmittance was 6.6% at a wavelength of 6.15 nm and an incident angle of 80 deg.

  2. Bactericidal effect of a 405-nm diode laser on Porphyromonas gingivalis

    Energy Technology Data Exchange (ETDEWEB)

    Kotoku, Y; Kato, J; Akashi, G; Hirai, Y [Department of Operative Dentistry, Tokyo Dental College, 1-2-2, Masago, Mihama-ku, Chiba, 261-8502 (Japan); Ishihara, K [Department of Microbiology, Tokyo Dental College, 1-2-2, Masago, Mihama-ku, Chiba, 261-8502 (Japan)

    2009-05-15

    The study was conducted to determine the effect of 405-nm diode laser irradiation on periodontopathic bacteria such as Porphyromonas gingivalis in vitro. A diluted suspension of P. gingivalis was irradiated directly with a 405-nm diode laser under conditions of 100 mW-10 sec, 100 mW-20 sec, 200 mW-5 sec, 200 mW-10 sec, 200 mW-20 sec, 400 mW-5 sec, 400 mW-10 sec, and 400 mW-20 sec. The energy density ranged from 2.0 to 16.0 J/cm{sup 2}. The irradiated bacterial suspension was spread on a blood agar plate and growth of the colonies was examined after an anaerobic culture for 7 days. Bacterial growth was inhibited under all irradiation conditions, but the bactericidal effect of the 405-nm diode laser depended on the energy density. More than 97% of bacterial growth was inhibited with irradiation at an energy density > 4.0 J/cm{sup 2}. The mechanism of the bactericidal effect is photochemical, rather than photothermal. These findings suggest that a 405-nm diode laser has a high bactericidal effect on P. gingivalis.

  3. Bactericidal effect of a 405-nm diode laser on Porphyromonas gingivalis

    International Nuclear Information System (INIS)

    Kotoku, Y; Kato, J; Akashi, G; Hirai, Y; Ishihara, K

    2009-01-01

    The study was conducted to determine the effect of 405-nm diode laser irradiation on periodontopathic bacteria such as Porphyromonas gingivalis in vitro. A diluted suspension of P. gingivalis was irradiated directly with a 405-nm diode laser under conditions of 100 mW-10 sec, 100 mW-20 sec, 200 mW-5 sec, 200 mW-10 sec, 200 mW-20 sec, 400 mW-5 sec, 400 mW-10 sec, and 400 mW-20 sec. The energy density ranged from 2.0 to 16.0 J/cm 2 . The irradiated bacterial suspension was spread on a blood agar plate and growth of the colonies was examined after an anaerobic culture for 7 days. Bacterial growth was inhibited under all irradiation conditions, but the bactericidal effect of the 405-nm diode laser depended on the energy density. More than 97% of bacterial growth was inhibited with irradiation at an energy density > 4.0 J/cm 2 . The mechanism of the bactericidal effect is photochemical, rather than photothermal. These findings suggest that a 405-nm diode laser has a high bactericidal effect on P. gingivalis

  4. Bactericidal effect of a 405-nm diode laser on Porphyromonas gingivalis

    Science.gov (United States)

    Kotoku, Y.; Kato, J.; Akashi, G.; Hirai, Y.; Ishihara, K.

    2009-05-01

    The study was conducted to determine the effect of 405-nm diode laser irradiation on periodontopathic bacteria such as Porphyromonas gingivalis in vitro. A diluted suspension of P. gingivalis was irradiated directly with a 405-nm diode laser under conditions of 100 mW-10 sec, 100 mW-20 sec, 200 mW-5 sec, 200 mW-10 sec, 200 mW-20 sec, 400 mW-5 sec, 400 mW-10 sec, and 400 mW-20 sec. The energy density ranged from 2.0 to 16.0 J/cm2. The irradiated bacterial suspension was spread on a blood agar plate and growth of the colonies was examined after an anaerobic culture for 7 days. Bacterial growth was inhibited under all irradiation conditions, but the bactericidal effect of the 405-nm diode laser depended on the energy density. More than 97% of bacterial growth was inhibited with irradiation at an energy density > 4.0 J/cm2. The mechanism of the bactericidal effect is photochemical, rather than photothermal. These findings suggest that a 405-nm diode laser has a high bactericidal effect on P. gingivalis.

  5. Bandgap Engineering of 1300 nm Quantum Dots/Quantum Well Nanostructures Based Devices

    KAUST Repository

    Alhashim, Hala H.

    2016-05-29

    The main objectives of this thesis are to develop viable process and/or device technologies for bandgap tuning of 1300-nm InGaAs/GaAs quantum-dot (QD) laser structures, and broad linewidth 1300-nm InGaAsP/InP quantum well (QW) superluminescent diode structures. The high performance bandgap-engineered QD laser structures were achieved by employing quantum-dot intermixing (QDI) based on impurity free vacancy diffusion (IFVD) technique for eventual seamless active-passive integration, and bandgap-tuned lasers. QDI using various dielectric-capping materials, such as HfO2, SrTiO3, TiO2, Al2O3 and ZnO, etc, were experimented in which the resultant emission wavelength can be blueshifted to ∼ 1100 nm ─ 1200 nm range depending on process conditions. The significant results extracted from the PL characterization were used to perform an extensive laser characterization. The InAs/GaAs quantum-dot lasers with QDs transition energies were blueshifted by ~185 nm, and lasing around ~1070 – 1190 nm was achieved. Furthermore, from the spectral analysis, a simultaneous five-state lasing in the InAs/InGaAs intermixed QD laser was experimentally demonstrated for the first time in the very important wavelength range from 1030 to 1125 nm. The QDI methodology enabled the facile formation of a plethora of devices with various emission wavelengths suitable for a wide range of applications in the infrared. In addition, the wavelength range achieved is also applicable for coherent light generation in the green – yellow – orange visible wavelength band via frequency doubling, which is a cost-effective way of producing compact devices for pico-projectors, semiconductor laser based solid state lighting, etc. [1, 2] In QW-based superluminescent diode, the problem statement lies on achieving a flat-top and ultra-wide emission bandwidth. The approach was to design an inhomogeneous active region with a comparable simultaneous emission from different transition states in the QW stacks, in

  6. Low-threshold stimulated emission at 249 nm and 256 nm from AlGaN-based multiple-quantum-well lasers grown on sapphire substrates

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiao-Hang; Detchprohm, Theeradetch; Kao, Tsung-Ting; Satter, Md. Mahbub; Shen, Shyh-Chiang; Douglas Yoder, P.; Dupuis, Russell D., E-mail: dupuis@gatech.edu [Center for Compound Semiconductors and School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0250 (United States); Wang, Shuo; Wei, Yong O.; Xie, Hongen; Fischer, Alec M.; Ponce, Fernando A. [Department of Physics, Arizona State University, Tempe, Arizona 85287-1504 (United States); Wernicke, Tim; Reich, Christoph; Martens, Martin; Kneissl, Michael [Technical University of Berlin, Institute for Solid State Physics, Berlin D-10623 (Germany)

    2014-10-06

    Optically pumped deep-ultraviolet (DUV) lasing with low threshold was demonstrated from AlGaN-based multiple-quantum-well (MQW) heterostructures grown on sapphire substrates. The epitaxial layers were grown pseudomorphically by metalorganic chemical vapor deposition on (0001) sapphire substrates. Stimulated emission was observed at wavelengths of 256 nm and 249 nm with thresholds of 61 kW/cm{sup 2} and 95 kW/cm{sup 2} at room temperature, respectively. The thresholds are comparable to the reported state-of-the-art AlGaN-based MQW DUV lasers grown on bulk AlN substrates emitting at 266 nm. These low thresholds are attributed to the optimization of active region and waveguide layer as well as the use of high-quality AlN/sapphire templates. The stimulated emission above threshold was dominated by transverse-electric polarization. This work demonstrates the potential candidacy of sapphire substrates for DUV diode lasers.

  7. Low-threshold stimulated emission at 249 nm and 256 nm from AlGaN-based multiple-quantum-well lasers grown on sapphire substrates

    International Nuclear Information System (INIS)

    Li, Xiao-Hang; Detchprohm, Theeradetch; Kao, Tsung-Ting; Satter, Md. Mahbub; Shen, Shyh-Chiang; Douglas Yoder, P.; Dupuis, Russell D.; Wang, Shuo; Wei, Yong O.; Xie, Hongen; Fischer, Alec M.; Ponce, Fernando A.; Wernicke, Tim; Reich, Christoph; Martens, Martin; Kneissl, Michael

    2014-01-01

    Optically pumped deep-ultraviolet (DUV) lasing with low threshold was demonstrated from AlGaN-based multiple-quantum-well (MQW) heterostructures grown on sapphire substrates. The epitaxial layers were grown pseudomorphically by metalorganic chemical vapor deposition on (0001) sapphire substrates. Stimulated emission was observed at wavelengths of 256 nm and 249 nm with thresholds of 61 kW/cm 2 and 95 kW/cm 2 at room temperature, respectively. The thresholds are comparable to the reported state-of-the-art AlGaN-based MQW DUV lasers grown on bulk AlN substrates emitting at 266 nm. These low thresholds are attributed to the optimization of active region and waveguide layer as well as the use of high-quality AlN/sapphire templates. The stimulated emission above threshold was dominated by transverse-electric polarization. This work demonstrates the potential candidacy of sapphire substrates for DUV diode lasers.

  8. 38 CFR 23.310 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Recruitment. 23.310... Discrimination on the Basis of Sex in Admission and Recruitment Prohibited § 23.310 Recruitment. (a) Nondiscriminatory recruitment. A recipient to which §§ 23.300 through 23.310 apply shall not discriminate on the...

  9. Raman Spectra and Bulk Modulus of Nanodiamond in a Size Interval of 2-5 nm

    Science.gov (United States)

    Popov, Mikhail; Churkin, Valentin; Kirichenko, Alexey; Denisov, Viktor; Ovsyannikov, Danila; Kulnitskiy, Boris; Perezhogin, Igor; Aksenenkov, Viktor; Blank, Vladimir

    2017-10-01

    Nanodiamond in a 2-5-nm size interval (which is typical for an appearance of quantum confinement effect) show Raman spectra composed of 3 bands at 1325, 1600, and 1500 cm-1 (at the 458-nm laser excitation) which shifts to 1630 cm-1 at the 257-nm laser excitation. Contrary to sp2-bonded carbon, relative intensities of the bands do not depend on the 458- and 257-nm excitation wavelengths, and a halfwidth and the intensity of the 1600 cm-1 band does not change visibly under pressure at least up to 50 GPa. Bulk modulus of the 2-5-nm nanodiamond determined from the high-pressure study is around 560 GPa. Studied 2-5-nm nanodiamond was purified from contamination layers and dispersed in Si or NaCl.

  10. Grating writing and growth at 325nm in non-hydrogenated silica fiber

    DEFF Research Database (Denmark)

    Town, Graham E; Yuan, Scott Wu; Stefani, Alessio

    We report on the writing and growth dynamics of Bragg gratings written in standard silica fiber using a 325nm He:Cd laser.......We report on the writing and growth dynamics of Bragg gratings written in standard silica fiber using a 325nm He:Cd laser....

  11. Magnetic structures of Er6Mn23 and Dy6Mn23

    International Nuclear Information System (INIS)

    Ouladdiaf, B.; Deportes, J.; Rodriguez-Carvajal, J.

    1995-01-01

    The R 6 Mn 23 (R=rare earth) compounds crystallize in the cubic Th 6 Mn 23 -type structure with space group Fm3m. Powder neutron-diffraction experiments were performed on Dy 6 Mn 23 and Er 6 Mn 23 . The magnetic unit cell coincides with the chemical one. The R moments have a ferromagnetic non-collinear arrangement, whereas the Mn moments are parallel to the [1 1 1] direction. The magnetic structures belong to the three-dimensional Γ 5g irreducible representation of Fm3m associated with the wave vector K=[0 0 0]. The spin configurations in both compounds result from the competition between the R-R, R-Mn magnetic interactions and the crystal electric field on the R ions. (orig.)

  12. Optical limiting properties of 3,5-dipyrenylvinyleneBODIPY dyes at 532 nm

    Science.gov (United States)

    Kubheka, Gugu; Sanusi, Kayode; Mack, John; Nyokong, Tebello

    2018-02-01

    The optical limiting (OL) properties of 3,5-dipyrenylvinyleneBODIPY dyes that contain both electron withdrawing and donating moieties have been investigated by using the z-scan technique at 532 nm in the nanosecond pulse range. The extension of the π-conjugation at the 3,5-positions with pyrenylvinylene groups results in a ca. 200 nm red shift of the main BODIPY spectral band to ca. 700 nm, so there is relatively weak absorbance at 532 nm under ambient light conditions. Reverse saturable absorbance (RSA) profiles are observed in response to incident pulsed laser light that is consistent with a two photon absorption-assisted excited state absorption (ESA) mechanism in CH2Cl2 solution and when the dyes are embedded in poly(bisphenol carbonate A) (PBC) polymer thin films. This demonstrates that 3,5-divinyleneBODIPY dyes are potentially suitable for use in OL applications, since limiting threshold fluence (Ilim) values of below 0.95 J cm-2 are observed when thin films are prepared.

  13. High-resolution magnetic-domain imaging by Fourier transform holography at 21 nm wavelength

    International Nuclear Information System (INIS)

    Schaffert, Stefan; Pfau, Bastian; Günther, Christian M; Schneider, Michael; Korff Schmising, Clemens von; Eisebitt, Stefan; Geilhufe, Jan

    2013-01-01

    Exploiting x-ray magnetic circular dichroism at the L-edges of 3d transition metals, Fourier transform holography has become a standard technique to investigate magnetic samples with sub-100 nm spatial resolution. Here, magnetic imaging in the 21 nm wavelength regime using M-edge circular dichroism is demonstrated. Ultrafast pulses in this wavelength regime are increasingly available from both laser- and accelerator-driven soft x-ray sources. We explain the adaptations concerning sample preparation and data evaluation compared to conventional holography in the 1 nm wavelength range. We find the correction of the Fourier transform hologram to in-plane Fourier components to be critical for high-quality reconstruction and demonstrate 70 nm spatial resolution in magnetization imaging with this approach. (paper)

  14. Ablation of the Galnt3 gene leads to low-circulating intact fibroblast growth factor 23 (Fgf23) concentrations and hyperphosphatemia despite increased Fgf23 expression.

    Science.gov (United States)

    Ichikawa, Shoji; Sorenson, Andrea H; Austin, Anthony M; Mackenzie, Donald S; Fritz, Timothy A; Moh, Akira; Hui, Siu L; Econs, Michael J

    2009-06-01

    Familial tumoral calcinosis is characterized by ectopic calcifications and hyperphosphatemia. The disease is caused by inactivating mutations in fibroblast growth factor 23 (FGF23), Klotho (KL), and uridine diphosphate-N-acetyl-alpha-D-galactosamine:polypeptide N-acetylgalactosaminyltransferase 3 (GALNT3). In vitro studies indicate that GALNT3 O-glycosylates a phosphaturic hormone, FGF23, and prevents its proteolytic processing, thereby allowing secretion of intact FGF23. In this study we generated mice lacking the Galnt3 gene, which developed hyperphosphatemia without apparent calcifications. In response to hyperphosphatemia, Galnt3-deficient mice had markedly increased Fgf23 expression in bone. However, compared with wild-type and heterozygous littermates, homozygous mice had only about half of circulating intact Fgf23 levels and higher levels of C-terminal Fgf23 fragments in bone. Galnt3-deficient mice also exhibited an inappropriately normal 1,25-dihydroxyvitamin D level and decreased alkaline phosphatase activity. Furthermore, renal expression of sodium-phosphate cotransporters and Kl were elevated in Galnt3-deficient mice. Interestingly, there were sex-specific phenotypes; only Galnt3-deficient males showed growth retardation, infertility, and significantly increased bone mineral density. In summary, ablation of Galnt3 impaired secretion of intact Fgf23, leading to decreased circulating Fgf23 and hyperphosphatemia, despite increased Fgf23 expression. Our findings indicate that Galnt3-deficient mice have a biochemical phenotype of tumoral calcinosis and provide in vivo evidence that Galnt3 plays an essential role in proper secretion of Fgf23 in mice.

  15. Narrow line width operation of a 980 nm gain guided tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Barrientos-Barria, Jessica

    2011-01-01

    We demonstrate two different schemes for the spectral narrowing of a 12 emitter 980 nm gain guided tapered diode laser bar. In the first scheme, a reflective grating has been used in a Littman Metcalf configuration and the wavelength of the laser emission could be narrowed down from more than 5.......5 nm in the free running mode to 0.04 nm (FWHM) at an operating current of 30 A with an output power of 8 W. The spectrum was found to be tunable within a range of 16 nm. In the second scheme, a volume Bragg grating has been used to narrow the wavelength of the laser bar from over 5 nm to less than 0.......2 nm with an output of 5 W at 20 A. To our knowledge, this is the first time spectral narrowing has been performed on a gain guided tapered diode laser bar. In the Littman Metcalf configuration, the spectral brightness has been increased by 86 times and in the volume Bragg grating cavity the spectral...

  16. Northern Edge Navajo Casino, Fruitland, NM: NN0030343

    Science.gov (United States)

    NPDES Permit and Fact Sheet explaining EPA's action under the Clean Water Act to issue NPDES Permit No. NN0030343) to the Navajo Tribal Utility Authority Northern Edge Navajo Casino Wastewater Treatment Facility, 2752 Indian Service Road 36, Fruitland, NM.

  17. 650 nm Laser stimulated dating from Side Antique Theatre, Turkey

    International Nuclear Information System (INIS)

    Doğan, M.; Meriç, N.

    2014-01-01

    Samples were taken from the archeological excavation site, which was at the backs of the Side Antique Theatre. Samples were taken from under the base rock in this area. Polymineral fine grains were examined to determine the ages of the sediments. Samples gathered from the Side Antique Theatre were investigated through using the SAR method. Firstly, one part of the samples were evaluated by using conventional IRSL reading head model of (ELSEC-9010) which is infrared (880±80 nm) stimulation source with Schott BG39 filter. The IRSL age dating with feldspar minerals, gives a number of overestimated or underestimated age values as a result. A new reading head was proposed with the following configuration attachments for overestimation of equivalent dose rates. Measurements were done with this newly designed red laser stimulating reading head which works with Elsec 9010 OSL age dating system. SAR measurements were performed by (650±10 nm) red laser light source with two Schott BG3 filters. With usage of the new designed reading head; closer results were obtained in comparision with the Antique Theatre′s expected age range. Fading rates were taken into consideration and these corrections were also handled for true age results. - Highlights: • Polymineral fine grain feldspar minerals were used for dating. • Two different reading heads were used to determine equivalent doses. • IR stimulated (880 nm) and laser stimulated (650 nm) dating results were compared

  18. Spectral narrowing of a 980 nm tapered diode laser bar

    Science.gov (United States)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Lucas Leclin, Ga"lle; Petersen, Paul Michael; Thestrup, Birgitte

    2011-03-01

    High power diode laser bars are interesting in many applications such as solid state laser pumping, material processing, laser trapping, laser cooling and second harmonic generation. Often, the free running laser bars emit a broad spectrum of the order of several nanometres which limit their scope in wavelength specific applications and hence, it is vital to stabilize the emission spectrum of these devices. In our experiment, we describe the wavelength narrowing of a 12 element 980 nm tapered diode laser bar using a simple Littman configuration. The tapered laser bar which suffered from a big smile has been "smile corrected" using individual phase masks for each emitter. The external cavity consists of the laser bar, both fast and slow axis micro collimators, smile correcting phase mask, 6.5x beam expanding lens combination, a 1200 lines/mm reflecting grating with 85% efficiency in the first order, a slow axis focusing cylindrical lens of 40 mm focal length and an output coupler which is 10% reflective. In the free running mode, the laser emission spectrum was 5.5 nm wide at an operating current of 30A. The output power was measured to be in excess of 12W. Under the external cavity operation, the wavelength spread of the laser could be limited to 0.04 nm with an output power in excess of 8 W at an operating current of 30A. The spectrum was found to be tuneable in a range of 16 nm.

  19. TARDEC Ground Vehicle Robotics: Vehicle Dynamic Characterization and Research

    Science.gov (United States)

    2015-09-01

    subassemblies that would be common on ground vehicles. Powertrain Systems: Gas Powered, Diesel , Turbo Diesel , Gas Turbine, Hybrid: Gas- Electric...PROPULSE (Hybrid Diesel - Electric System with Export Power), Command Zone (integrated vehicle control and diagnostic system), and TerraMax (Unmanned... Diesel -Electric, Series, Parallel. Power Distribution: RWD, FWD, AWD, open diff, LSD, Torsen diff, differential braking (traction control), drive by

  20. Optical Pumping of Molecular Gases

    Science.gov (United States)

    1976-04-01

    ser emission ott a The typical experimental apparatus is shown i.- Fig. *series of green and yellow molecular B-X’-basnd transi- 2. For B-bantd optical...with A, at 0. 473 pim and that Na2 may operate as a flash -lamp -pumped laser X,... at 0. 54 umn the Doppler widths are AwD - 12.42 source with buffer

  1. Increase of the photosensitivity of undoped poly(methylmethacrylate) under UV radiation at 325 nm

    DEFF Research Database (Denmark)

    Sáez-Rodríguez, D.; Nielsen, Kristian; Bang, Ole

    2014-01-01

    in undoped PMMA mPOFs with a hexagonal structure of three rings in the inner cladding. Two sets of FBGs were inscribed at two different resonant wavelengths (827 nm and 1562 nm) at different strains using an UV He-Cd laser at 325 nm focused by a lens and scanned over the fibre. We observed an increase...

  2. Engineering Nanowire n-MOSFETs at L_{g}<8 nm

    Science.gov (United States)

    Mehrotra, Saumitra R.; Kim, SungGeun; Kubis, Tillmann; Povolotskyi, Michael; Lundstrom, Mark S.; Klimeck, Gerhard

    2013-07-01

    As metal-oxide-semiconductor field-effect transistors (MOSFET) channel lengths (Lg) are scaled to lengths shorter than Lg<8 nm source-drain tunneling starts to become a major performance limiting factor. In this scenario a heavier transport mass can be used to limit source-drain (S-D) tunneling. Taking InAs and Si as examples, it is shown that different heavier transport masses can be engineered using strain and crystal orientation engineering. Full-band extended device atomistic quantum transport simulations are performed for nanowire MOSFETs at Lg<8 nm in both ballistic and incoherent scattering regimes. In conclusion, a heavier transport mass can indeed be advantageous in improving ON state currents in ultra scaled nanowire MOSFETs.

  3. Single, composite, and ceramic Nd:YAG 946-nm lasers

    Science.gov (United States)

    Lan, Rui-Jun; Yang, Guang; Zheng-Ping, Wang

    2015-06-01

    Single, composite crystal and ceramic continuous wave (CW) 946-nm Nd:YAG lasers are demonstrated, respectively. The ceramic laser behaves better than the crystal laser. With 5-mm long ceramic, a CW output power of 1.46 W is generated with an optical conversion efficiency of 13.9%, while the slope efficiency is 17.9%. The optimal ceramic length for a 946-nm laser is also calculated. Project supported by the National Natural Science Foundation of China (Grant No. 61405171), the Natural Science Foundation of Shandong Province, China (Grant No. ZR2012FQ014), and the Science and Technology Program of the Shandong Higher Education Institutions of China (Grant No. J13LJ05).

  4. Chaos, Consternation and CALIPSO Calibration: New Strategies for Calibrating the CALIOP 1064 nm Channel

    Science.gov (United States)

    Vaughan, Mark; Garnier, Anne; Liu, Zhaoyan; Josset, Damien; Hu, Yongxiang; Lee, Kam-Pui; Hunt, William; Vernier, Jean-Paul; Rodier, Sharon; Pelon, Jaques; hide

    2012-01-01

    The very low signal-to-noise ratios of the 1064 nm CALIOP molecular backscatter signal make it effectively impossible to employ the "clear air" normalization technique typically used to calibrate elastic back-scatter lidars. The CALIPSO mission has thus chosen to cross-calibrate their 1064 nm measurements with respect to the 532 nm data using the two-wavelength backscatter from cirrus clouds. In this paper we discuss several known issues in the version 3 CALIOP 1064 nm calibration procedure, and describe the strategies that will be employed in the version 4 data release to surmount these problems.

  5. Influence of ultra-thin TiN thickness (1.4 nm and 2.4 nm) on positive bias temperature instability (PBTI) of high-k/metal gate nMOSFETs with gate-last process

    International Nuclear Information System (INIS)

    Qi Lu-Wei; Yang Hong; Ren Shang-Qing; Xu Ye-Feng; Luo Wei-Chun; Xu Hao; Wang Yan-Rong; Tang Bo; Wang Wen-Wu; Yan Jiang; Zhu Hui-Long; Zhao Chao; Chen Da-Peng; Ye Tian-Chun

    2015-01-01

    The positive bias temperature instability (PBTI) degradations of high-k/metal gate (HK/MG) nMOSFETs with thin TiN capping layers (1.4 nm and 2.4 nm) are systemically investigated. In this paper, the trap energy distribution in gate stack during PBTI stress is extracted by using ramped recovery stress, and the temperature dependences of PBTI (90 °C, 125 °C, 160 °C) are studied and activation energy (E a ) values (0.13 eV and 0.15 eV) are extracted. Although the equivalent oxide thickness (EOT) values of two TiN thickness values are almost similar (0.85 nm and 0.87 nm), the 2.4-nm TiN one (thicker TiN capping layer) shows better PBTI reliability (13.41% at 0.9 V, 90 °C, 1000 s). This is due to the better interfacial layer/high-k (IL/HK) interface, and HK bulk states exhibited through extracting activation energy and trap energy distribution in the high-k layer. (paper)

  6. Design and Fabrication of 850 and 980 nm Vertical Cavity Surface Emitting Laser

    National Research Council Canada - National Science Library

    Das, N

    2004-01-01

    .... VCSELs on GaAs substrates were grown by the molecular beam epitaxy technique. In this report we present detailed procedures to design and fabricate 850-nm top-emitting and 980-nm bottom-emitting VCSELs...

  7. Photolysis of butenedial at 193, 248, 280, 308, 351, 400, and 450 nm

    Science.gov (United States)

    Tang, Yongxin; Zhu, Lei

    2005-06-01

    We have studied the photolysis of butenedial at 193, 248, 280, 308, 351, 400, and 450 nm by using laser photolysis combined with cavity ring-down spectroscopy. The HCO radical is a photodissociation product at 193 and 248 nm. The corresponding HCO quantum yields are 0.55 ± 0.07 and 0.12 ± 0.01, independent of butenedial pressure and nitrogen buffer gas pressure. Absorption cross-sections of butenedial are (6.88 ± 0.39) × 10 -18 and (3.62 ± 0.69) × 10 -19 cm 2 at 193 and 248 nm. The end-products from the photolysis of butenedial at 193, 248, 308, and 351 nm were measured by FTIR. Acrolein and 3H-furan-2-one were observed and their yields have been estimated.

  8. Strongly Coupled Tin-Halide Perovskites to Modulate Light Emission: Tunable 550-640 nm Light Emission (FWHM 36-80 nm) with a Quantum Yield of up to 6.4.

    Science.gov (United States)

    Chen, Min-Yi; Lin, Jin-Tai; Hsu, Chia-Shuo; Chang, Chung-Kai; Chiu, Ching-Wen; Chen, Hao Ming; Chou, Pi-Tai

    2018-05-01

    Colloidal perovskite quantum dots represent one of the most promising materials for applications in solar cells and photoluminescences. These devices require a low density of crystal defects and a high yield of photogenerated carriers, which are difficult to realize in tin-halide perovskite because of the intrinsic instability of tin during nucleation. Here, an enhancement in the luminescent property of tin-halide perovskite nanoplates (TPNPs) that are composed of strongly coupled layered structures with the chemical formula of PEA 2 SnX 4 (PEA = C 6 H 5 (CH 2 ) 2 NH 3 , X = Br, I) is reported. TPNPs (X = I) show an emission at a wavelength of 640 nm, with high quantum yield of 6.40 ± 0.14% and full width at half maximum (FWHM) as small as 36 nm. The presence of aliphatic carboxylic acid is found to play a key role in reducing the tin perovskite defect density, which significantly improves the emission intensity and stability of TPNPs. Upon mixing iodo- and bromo- precursors, the emission wavelength is successfully tuned from 640 nm (PEA 2 SnI 4 ) to 550 nm (PEA 2 SnBr 4 ), with a corresponding emission quantum yield and FWHM of 0.16-6.40% and 36-80 nm, respectively. The results demonstrate a major advance for the emission yield and tunability of tin-halide perovskites. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Epitaxial Pb(Mg1/3Nb2/3)O3 thin films synthesized by metal-organic chemical vapor deposition

    International Nuclear Information System (INIS)

    Bai, G. R.; Streiffer, S. K.; Baumann, P. K.; Auciello, O.; Ghosh, K.; Stemmer, S.; Munkholm, A.; Thompson, Carol; Rao, R. A.; Eom, C. B.

    2000-01-01

    Metal-organic chemical vapor deposition was used to prepare Pb(Mg 1/3 Nb 2/3 )O 3 (PMN) thin films on (001) SrTiO 3 and SrRuO 3 /SrTiO 3 substrates, using solid Mg β-diketonate as the Mg precursor. Parameters including the precursor ratio in the vapor phase, growth temperature, growth rate, and reaction pressure in the reactor chamber were varied in order to determine suitable growth conditions for producing phase-pure, epitaxial PMN films. A cube-on-cube orientation relationship between the thin film and the SrTiO 3 substrate was found, with a (001) rocking curve width of 0.1 degree sign , and in-plane rocking-curve width of 0.8 degree sign . The root-mean-square surface roughness of a 200-nm-thick film on SrTiO 3 was 2 to 3 nm as measured by scanning probe microscopy. The zero-bias dielectric constant and loss measured at room temperature and 10 kHz for a 200-nm-thick film on SrRuO 3 /SrTiO 3 were approximately 1100 and 2%, respectively. The remnant polarization for this film was 16 μC/cm 2 . (c) 2000 American Institute of Physics

  10. Reduced nonlinearities in 100-nm high SOI waveguides

    Science.gov (United States)

    Lacava, C.; Marchetti, R.; Vitali, V.; Cristiani, I.; Giuliani, G.; Fournier, M.; Bernabe, S.; Minzioni, P.

    2016-03-01

    Here we show the results of an experimental analysis dedicated to investigate the impact of optical non linear effects, such as two-photon absorption (TPA), free-carrier absorption (FCA) and free-carrier dispersion (FCD), on the performance of integrated micro-resonator based filters for application in WDM telecommunication systems. The filters were fabricated using SOI (Silicon-on-Insulator) technology by CEA-Leti, in the frame of the FP7 Fabulous Project, which aims to develop low-cost and high-performance integrated optical devices to be used in new generation passive optical- networks (NG-PON2). Different designs were tested, including both ring-based structures and racetrack-based structures, with single-, double- or triple- resonator configuration, and using different waveguide cross-sections (from 500 x 200 nm to 825 x 100 nm). Measurements were carried out using an external cavity tunable laser source operating in the extended telecom bandwidth, using both continuous wave signals and 10 Gbit/s modulated signals. Results show that the use 100-nm high waveguide allows reducing the impact of non-linear losses, with respect to the standard waveguides, thus increasing by more than 3 dB the maximum amount of optical power that can be injected into the devices before causing significant non-linear effects. Measurements with OOK-modulated signals at 10 Gbit/s showed that TPA and FCA don't affect the back-to-back BER of the signal, even when long pseudo-random-bit-sequences (PRBS) are used, as the FCD-induced filter-detuning increases filter losses but "prevents" excessive signal degradation.

  11. The FIREBall-2 UV sample grating efficiency at 200-208nm

    Science.gov (United States)

    Quiret, S.; Milliard, B.; Grange, R.; Lemaitre, G. R.; Caillat, A.; Belhadi, M.; Cotel, A.

    2014-07-01

    The FIREBall-2 (Faint Intergalactic Redshifted Emission Balloon-2) is a balloon-borne ultraviolet spectro-imaging mission optimized for the study of faint diffuse emission around galaxies. A key optical component of the new spectrograph design is the high throughput cost-effective holographic 2400 ℓ =mm, 110x130mm aspherized reflective grating used in the range 200 - 208nm, near 28°deviation angle. In order to anticipate the efficiency in flight conditions, we have developed a PCGrate model for the FIREBall grating calibrated on linearly polarized measurements at 12° deviation angle in the range 240-350nm of a 50x50mm replica of the same master selected for the flight grating. This model predicts an efficiency within [64:7; 64:9]+/-0:7% (S polarization) and [38:3; 45]+/-2:2% (P-polarization) for the baseline aluminum coated grating with an Al2O3 natural oxidation layer and within [63:5; 65] +/-1% (S-polarization) and [51:3; 54:8] +/-2:8% (P-polarization) for an aluminum plus a 70nm MgF2 coating, in the range 200 - 208nm and for a 28°deviation angle. The model also shows there is room for significant improvements at shorter wavelengths, of interest for future deep UV spectroscopic missions.

  12. Characterization, 1064 nm photon signals and background events of a tungsten TES detector for the ALPS experiment

    International Nuclear Information System (INIS)

    Dreyling-Eschweiler, J.; Doebrich, B.; Januschek, F.; Lindner, A.; Bastidon, N.; Horns, D.

    2015-02-01

    The high efficiency, low-background, and single-photon detection with transition-edge sensors (TES) is making this type of detector attractive in widely different types of application. In this paper, we present first characterizations of a TES to be used in the Any Light Particle Search (ALPS) experiment searching for new fundamental ultra-light particles. Firstly, we describe the setup and the main components of the ALPS TES detector (TES, millikelvin-cryostat and SQUID read-out) and their performances. Secondly, we explain a dedicated analysis method for single-photon spectroscopy and rejection of non-photon background. Finally, we report on results from extensive background measurements. Considering an event-selection, optimized for a wavelength of 1064 nm, we achieved a background suppression of ∝10 -3 with a ∝ 50 % efficiency for photons passing the selection. The resulting overall efficiency was 23 % with a dark count rate of 8.6.10 -3 s -1 . We observed that pile-up events of thermal photons are the main background component.

  13. Water line positions in the 782–840 nm region

    International Nuclear Information System (INIS)

    Hu, S.-M.; Chen, B.; Tan, Y.; Wang, J.; Cheng, C.-F.; Liu, A.-W.

    2015-01-01

    A set of water transitions in the 782–840 nm region, including 38 H 2 16 O lines, 12 HD 16 O lines, and 30 D 2 16 O lines, were recorded with a cavity ring-down spectrometer calibrated using precise atomic lines. Absolute frequencies of the lines were determined with an accuracy of about 5 MHz. Systematic shifts were found in the line positions given in the HITRAN database and the upper energy levels given in recent MARVEL studies. - Highlights: • Cavity ring-down spectra of H 2 16 O, HD 16 O, and D 2 16 O lines in the 782–840 nm region were measured. • Absolute line positions of 80 water lines were determined with an accuracy of about 5 MHz. • The H 2 16 O positions given in HITRAN have a systematic shift of 0.001 cm −1 in the 796–840 nm region. • MARVEL D 2 16 O energies have a systematic deviation of about −0.008 cm −1

  14. Growth regulation of HeLa cells by 1060 nm photons

    International Nuclear Information System (INIS)

    Torghele, K. F.

    1993-12-01

    Living organisms are open systems dominated by electromagnetic interaction. An essential feature of a living system is its cybernetic process which imply their capability of adaptation and sensitivity to internal and external fluctuations. The experimental results show that coherent and incoherent light of 1060 nm wavelength influences the metabolic processes and consequently the proliferation of cancer cell cultures (HeLa). Light induced regulation of HeLa cell growth depends on the cell density, the state of the cell culture and the amount of light irradiation. Best proliferation inhibiting effects can be obtained by application of 200 J/m 2 on HeLa cells in Lag-Phase and a typical cell density of 5.10 4 cells/cm 2 . Proceeding on the singlet oxygen hypothesis (KLIMA, H. et al.; 1990), it is shown mathematically that the dynamical behaviour of the NADH model is influenced by 1060 nm photons. Both, the experimental and the numerical results support our hypothesis: 1060 nm photons regulate the proliferation of HeLa cells. (author)

  15. Synthesis and characterization of metastable, 20 nm-sized Pna21-LiCoPO4 nanospheres

    International Nuclear Information System (INIS)

    Ludwig, Jennifer; Nordlund, Dennis; Doeff, Marca M.; Nilges, Tom

    2017-01-01

    The majority of research activities on LiCoPO 4 are focused on the phospho-olivine (space group Pnma), which is a promising high-voltage cathode material for Li-ion batteries. In contrast, comparably little is known about its metastable Pna2 1 modification. Herein, we present a comprehensive study on the structure–property relationships of 15–20 nm Pna2 1 -LiCoPO 4 nanospheres prepared by a simple microwave-assisted solvothermal process. Unlike previous reports, the results indicate that the compound is non-stoichiometric and shows cation-mixing with Co ions on the Li sites, which provides an explanation for the poor electrochemical performance. Co L 2,3 -edge X-ray absorption spectroscopic data confirm the local tetrahedral symmetry of Co 2+ . Comprehensive studies on the thermal stability using thermogravimetric analysis, differential scanning calorimetry, and in situ powder X-ray diffraction show an exothermic phase transition to olivine Pnma-LiCoPO 4 at 527 °C. The influence of the atmosphere and the particle size on the thermal stability is also investigated. - Graphical abstract: Blue nano-sized Pna2 1 -LiCoPO 4, featuring tetrahedrally-coordinated Co 2+ , was synthesized in a rapid one-step microwave-assisted solvothermal process. The phase relation between this metastable and the stable polymorph was analyzed and electrochemical properties are discussed. - Highlights: • Preparation of uniform 15–20 nm nanospheres of metastable Pna2 1 -LiCoPO 4 polymorph. • Structure redetermination shows cation-mixing (Co blocking Li sites). • In situ investigation of phase transformation to olivine Pnma-LiCoPO 4 at 527 °C. • Pna2 1 -LiCoPO 4 reemerges as a stable high-temperature phase above 800 °C. • X-ray absorption spectroscopy confirms local tetrahedral symmetry (T d Co 2+ ).

  16. Advanced 65 nm CMOS devices fabricated using ultra-low energy plasma doping

    International Nuclear Information System (INIS)

    Walther, S.; Lenoble, D.; Lallement, F.; Grouillet, A.; Erokhin, Y.; Singh, V.; Testoni, A.

    2005-01-01

    For leading edge CMOS and DRAM technologies, plasma doping (PLAD) offers several unique advantages over conventional beamline implantation. For ultra-low energy source and drain extensions (SDE), source drain contact and high dose poly doping implants PLAD delivers 2-5x higher throughput compared to beamline implanters. In this work we demonstrate process performance and process integration benefits enabled by plasma doping for advanced 65 nm CMOS devices. Specifically, p + /n ultra-shallow junctions formed with BF 3 plasma doping have superior X j /R s characteristics to beamline implants and yield up to 30% lower R s for 20 nm X j while using standard spike anneal with ramp-up rate of 75 deg. C/s. These results indicate that PLAD could extend applicability of standard spike anneal by at least one technology node past 65 nm. A CMOS split lot has been run to investigate process integration advantages unique to plasma doping and to determine CMOS device characteristics. Device data measured on 65 nm transistors fabricated with offset spacers indicate that devices with SDE formed by plasma doping have superior V t roll-off characteristics arguably due to improved lateral gate-overlap of PLAD SDE junctions. Furthermore, offset spacers could be eliminated in 65 nm devices with PLAD SDE implants while still achieving V t roll-off and I on -I off performance at least equivalent to control devices with offset spacers and SDE formed by beamline implantation. Thus, another advantage of PLAD is simplified 65 nm CMOS manufacturing process flow due to elimination of offset spacers. Finally, we present process transfer from beamline implants to PLAD for several applications, including SDE and gate poly doping with very high productivity

  17. Computational Design of High-χ Block Oligomers for Accessing 1 nm Domains.

    Science.gov (United States)

    Chen, Qile P; Barreda, Leonel; Oquendo, Luis E; Hillmyer, Marc A; Lodge, Timothy P; Siepmann, J Ilja

    2018-05-22

    Molecular dynamics simulations are used to design a series of high-χ block oligomers (HCBOs) that can self-assemble into a variety of mesophases with domain sizes as small as 1 nm. The exploration of these oligomers with various chain lengths, volume fractions, and chain architectures at multiple temperatures reveals the presence of ordered lamellae, perforated lamellae, and hexagonally packed cylinders. The achieved periods are as small as 3.0 and 2.1 nm for lamellae and cylinders, respectively, which correspond to polar domains of approximately 1 nm. Interestingly, the detailed phase behavior of these oligomers is distinct from that of either solvent-free surfactants or block polymers. The simulations reveal that the behavior of these HCBOs is a product of an interplay between both "surfactant factors" (headgroup interactions, chain flexibility, and interfacial curvature) and "block polymer factors" (χ, chain length N, and volume fraction f). This insight promotes the understanding of molecular features pivotal for mesophase formation at the sub-5 nm length scale, which facilitates the design of HCBOs tailored toward particular desired morphologies.

  18. Many-electron effect in the resonant L23-M23V Auger-electron spectrum of Ti metal

    International Nuclear Information System (INIS)

    Ohno, Masahide

    2006-01-01

    Above the L23 absorption edge the L 23 -M 23 V resonant Auger-electron spectroscopy (RAES) spectrum of Ti metal shows a normal L 23 -M 23 V Auger decay spectrum at a constant kinetic energy (K.E.). Here LX and MY are the atomic shells Lx and My, respectively. Apart from a weak spectral feature of the L2-M23V Auger transition appearing around the L2 edge, the RAES spectra of Ti meal show a very little difference between the L2 and L3 regions [P. Le Fevre, J. Danger, H. Magnan, D. Chandesris, J. Jupille, S. Bourgeois, M.-A. Arrio, R. Gotter, A. Verdini, A. Morgante, Phys. Rev. B69 (2004) 155421]. It is shown that the time scale of relaxation of the resonantly excited L23-hole state to the L23-electron ionized state is much shorter than that of the L23-hole decay so that the L 23 -M 23 V RAES spectrum of Ti metal resembles much the normal L 23 -M 23 V Auger decay spectrum. The relaxation of the resonantly excited L23-hole state to the fully relaxed L23-hole state before the L23-hole decays, explains the extra width which is the primary cause of the discrepancy between the experimental high resolution near edge X-ray absorption spectroscopy (XAS) spectrum of Ti metal and the one calculated by the particle-hole Green's function including the Coulomb exchange interaction between the 2p hole and the 3d electron. The time scale of relaxation of the L3V two-hole state created by the L2-L3V Coster-Kronig (CK) decay to the single L3-hole state is much shorter than that of the L3-hole decay so that the L2-L3V-L3-M23V CK preceded Auger decay spectrum resembles much the L3-M23V Auger decay one

  19. Enzymatic degradation of cyclic 2,3-diphosphoglycerate to 2,3-diphosphoglycerate in Methanobacterium thermoautotrophicum

    International Nuclear Information System (INIS)

    Krishna Sastry, M.V.; Robertson, D.E.; Moynihan, J.A.; Roberts, M.F.

    1992-01-01

    2,3-Diphosphoglycerate (2,3-DPG) has been found to be the product of the enzymatic degradation of cyclic 2,3-diphosphoglycerate (cDPG) in the archaebacterium Methanobacterium thermoautotrophicum ΔH. Although 2,3-DPG has not previously been detected as a major soluble component of M. thermoautotrophicum, large pools accumulated at an incubation temperature of 50C. Under these conditions, cellular activity was significantly decreased; a return of the culture to the optimum growth temperature restored the 2,3-DPG pool back to original low levels and caused steady-state cDPG levels to increase again. While 13 CO 2 -pulse/ 12 CO 2 -chase experiments at 50C showed that the cDPG turned over, the appearance of 2,3-DPG at NMR-visible concentrations required at least 10 h. Production of 2,3-DPG in vivo was prevented by exposure of the cells to O 2 . the enzyme responsible for this hydrolysis of cDPG was purified by affinity chromatography and appears to be a 33-kDa protein. Activity was detected in the presence of oxygen and was enhanced by a solution of 1 M KCl, 25 mM MgCl 2 , and dithiothreitol. Both K m and V max have been determined at 37C; kinetics also indicate that in vitro the product, 2,3-DPG, is an inhibitor of cDPG hydrolysis. These findings are discussed in view of a proposed role for cDPG in methanogens

  20. Sub-10 nm colloidal lithography for circuit-integrated spin-photo-electronic devices

    Directory of Open Access Journals (Sweden)

    Adrian Iovan

    2012-12-01

    Full Text Available Patterning of materials at sub-10 nm dimensions is at the forefront of nanotechnology and employs techniques of various complexity, efficiency, areal scale, and cost. Colloid-based patterning is known to be capable of producing individual sub-10 nm objects. However, ordered, large-area nano-arrays, fully integrated into photonic or electronic devices have remained a challenging task. In this work, we extend the practice of colloidal lithography to producing large-area sub-10 nm point-contact arrays and demonstrate their circuit integration into spin-photo-electronic devices. The reported nanofabrication method should have broad application areas in nanotechnology as it allows ballistic-injection devices, even for metallic materials with relatively short characteristic relaxation lengths.

  1. Traceable X,Y self-calibration at single nm level of an optical microscope used for coherence scanning interferometry

    Science.gov (United States)

    Ekberg, Peter; Mattsson, Lars

    2018-03-01

    Coherence scanning interferometry used in optical profilers are typically good for Z-calibration at nm-levels, but the X,Y accuracy is often left without further notice than typical resolution limits of the optics, i.e. of the order of ~1 µm. For the calibration of metrology tools we rely on traceable artefacts, e.g. gauge blocks for traditional coordinate measurement machines, and lithographically mask made artefacts for microscope calibrations. In situations where the repeatability and accuracy of the measurement tool is much better than the uncertainty of the traceable artefact, we are bound to specify the uncertainty based on the calibration artefact rather than on the measurement tool. This is a big drawback as the specified uncertainty of a calibrated measurement may shrink the available manufacturing tolerance. To improve the uncertainty in X,Y we can use self-calibration. Then, we do not need to know anything more than that the artefact contains a pattern with some nominal grid. This also gives the opportunity to manufacture the artefact in-house, rather than buying a calibrated and expensive artefact. The self-calibration approach we present here is based on an iteration algorithm, rather than the traditional mathematical inversion, and it leads to much more relaxed constrains on the input measurements. In this paper we show how the X,Y errors, primarily optical distortions, within the field of view (FOV) of an optical coherence scanning interferometry microscope, can be reduced with a large factor. By self-calibration we achieve an X,Y consistency in the 175  ×  175 µm2 FOV of ~2.3nm (1σ) using the 50×  objective. Besides the calibrated coordinate X,Y system of the microscope we also receive, as a bonus, the absolute positions of the pattern in the artefact with a combined uncertainty of 6 nm (1σ) by relying on a traceable 1D linear measurement of a twin artefact at NIST.

  2. Evaluation of thermal damage in dental implants after irradiation with 980nm diode laser. An in vitro study

    Directory of Open Access Journals (Sweden)

    Carlo Cafiero

    2016-12-01

    Full Text Available Purpose: The aim of this study was to analyze the thermal damage in dental implants after irradiations with a 980nm diode laser, normally used for the decontamination. Material and Methods: Five Titanium Plasma Sprayed dental implants were irradiated with a 980nm diode laser at different parameters. Temperature increase on implant surface was evaluated by a Mid-Wavelength Infrared thermal-camera (Merlin®, FLIR, USA. Temperature increase (ΔT was compared to environmental temperature (27°C and recorded in three points: “A” (laser spot, “B” (3mm apically to the laser spot and “C” (2mm horizontally to the laser spot. Finally, a morphological evaluation at optical stereomicroscopy was performed. Results: When 0.6W power was applied, a moderate increase of temperature in point A (5.5°C-15.0°C, a slight increase in point B (0.1°C-6.2°C and point C (0.1°C-5.7°C, were registered after 30” of irradiation. In the samples treated at 6W, in “point A” an impressive ΔT increase was immediately recorded (over 70°C. In “point B” was recorded a slight ΔT after 2 sec. irradiation (range 2.3°C-6.0°C, a moderate ΔT after 4 sec. irradiation (16.4°C and a consistent ΔT after 8-10 sec. irradiation (range 36.6°C-46.2°C. In “point C” ΔT values were very similar to those collected in “point B”. Optical stereomicroscopy examination at a magnification of 32x did not show any surface alteration or damage after whichever laser irradiation independently from irradiation time and power output . Conclusions: 980nm diode laser, used at controlled parameters, can be used in the decontamination of dental implants, without causing any thermal damage or increase.

  3. Sub-10 nm low current resistive switching behavior in hafnium oxide stack

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Y., E-mail: houyi@pku.edu.cn, E-mail: lfliu@pku.edu.cn [Institute of Microelectronics, Peking University, 100871 Beijing (China); IMEC, Kapeldreef 75, B-3001 Heverlee (Belgium); Department of Physics and Astronomy, KU Leuven, Celestijnenlaan 200D, B-3001 Heverlee (Belgium); Celano, U.; Xu, Z.; Vandervorst, W. [IMEC, Kapeldreef 75, B-3001 Heverlee (Belgium); Department of Physics and Astronomy, KU Leuven, Celestijnenlaan 200D, B-3001 Heverlee (Belgium); Goux, L.; Fantini, A.; Degraeve, R.; Youssef, A.; Jurczak, M. [IMEC, Kapeldreef 75, B-3001 Heverlee (Belgium); Liu, L., E-mail: houyi@pku.edu.cn, E-mail: lfliu@pku.edu.cn; Cheng, Y.; Kang, J. [Institute of Microelectronics, Peking University, 100871 Beijing (China)

    2016-03-21

    In this letter, a tip-induced cell relying on the conductive atomic force microscope is proposed. It is verified as a referable replica of an integrated resistive random access memory (RRAM) device. On the basis of this cell, the functionality of sub-10 nm resistive switching is confirmed in hafnium oxide stack. Moreover, the low current switching behavior in the sub-10 nm dimension is found to be more pronounced than that of a 50 × 50 nm{sup 2} device. It shows better ON/OFF ratio and low leakage current. The enhanced memory performance is ascribed to a change in the shape of the conductive filament as the device dimensions are reduced to sub-10 nm. Therefore, device downscaling provides a promising approach for the resistance optimization that benefits the RRAM array design.

  4. Bacteria-free water for automatic washer-disinfectors: an impossible dream?

    Science.gov (United States)

    Cooke, R P; Whymant-Morris, A; Umasankar, R S; Goddard, S V

    1998-05-01

    The ability of a new automatic washer-disinfector system (AWDS), fitted with a water filtration system to provide bacteria-free water and so avoid the risk of mycobacterial contamination of fibreoptic bronchoscopes, was examined. Four new Astec 'MP' Safescope washer-disinfectors, with coarse and fine (0.2 micron) filters attached close to the outlet taps, were supplied with non-softened mains water. Water samples from the tank supply and outlet taps were regularly assessed for bacterial quality over a six-month period. Outlet samples were also analysed after fine filter change and purgation with peracetic acid. All bronchoalveolar lavage specimens (BALS) were stained and cultured for mycobacteria. Only 13 out of 53 outlet samples (24%) were culture-negative. There was no improvement after filter change. Residual anti-bacterial effect of peracetic acid lasted up to 48 h following AWDS purgation. No tank samples were bacteria-free. Sixty BALS were processed, two samples were culture-positive and grew M. tuberculosis and one was also smear-positive. Though mycobacterial contamination of bronchoscopes was not evident, the water filtration system was unable to reliably provide sterile rinse water.

  5. In vivo 808 nm image-guided photodynamic therapy based on an upconversion theranostic nanoplatform

    Science.gov (United States)

    Liu, Xiaomin; Que, Ivo; Kong, Xianggui; Zhang, Youlin; Tu, Langping; Chang, Yulei; Wang, Tong Tong; Chan, Alan; Löwik, Clemens W. G. M.; Zhang, Hong

    2015-09-01

    A new strategy for efficient in vivo image-guided photodynamic therapy (PDT) has been demonstrated utilizing a ligand-exchange constructed upconversion-C60 nanophotosensitizer. This theranostic platform is superior to the currently reported nanophotosensitizers in (i) directly bonding photosensitizer C60 to the surface of upconversion nanoparticles (UCNPs) by a smart ligand-exchange strategy, which greatly shortened the energy transfer distance and enhanced the 1O2 production, resulting in the improvement of the therapeutic effect; (ii) realizing in vivo NIR 808 nm image-guided PDT with both excitation (980 nm) and emission (808 nm) light falling in the biological window of tissues, which minimized auto-fluorescence, reduced light scatting and improved the imaging contrast and depth, and thus guaranteed noninvasive diagnostic accuracy. In vivo and ex vivo tests demonstrated its favorable bio-distribution, tumor-selectivity and high therapeutic efficacy. Owing to the effective ligand exchange strategy and the excellent intrinsic photophysical properties of C60, 1O2 production yield was improved, suggesting that a low 980 nm irradiation dosage (351 J cm-2) and a short treatment time (15 min) were sufficient to perform NIR (980 nm) to NIR (808 nm) image-guided PDT. Our work enriches the understanding of UCNP-based PDT nanophotosensitizers and highlights their potential use in future NIR image-guided noninvasive deep cancer therapy.A new strategy for efficient in vivo image-guided photodynamic therapy (PDT) has been demonstrated utilizing a ligand-exchange constructed upconversion-C60 nanophotosensitizer. This theranostic platform is superior to the currently reported nanophotosensitizers in (i) directly bonding photosensitizer C60 to the surface of upconversion nanoparticles (UCNPs) by a smart ligand-exchange strategy, which greatly shortened the energy transfer distance and enhanced the 1O2 production, resulting in the improvement of the therapeutic effect; (ii

  6. Calmyonemin: a 23 kDa analogue of algal centrin occurring in contractile myonemes of Eudiplodinium maggii (ciliate).

    Science.gov (United States)

    David, C; Viguès, B

    1994-01-01

    Myonemes are bundles of thin filaments (3-6 nm in diameter) which mediate calcium-induced contraction of the whole or only parts of the cell body in a number of protists. In Eudiplodinium maggii, a rumen ciliate which lacks a uniform ciliation of the cell body, myonemes converge toward the bases of apical ciliary zones that can be retracted under stress conditions, entailing immobilization of the cell. An mAB (A69) has been produced that identifies a calcium-binding protein by immunoblot, immunoprecipitation experiments and specifically labels the myonemes in immunoelectron microscopy. Solubility properties, apparent molecular weight (23 kDa) and isoelectric point (4.9) of the myonemal protein, are similar to the values reported for the calcium-modulated contractile protein centrin. Western-blot analysis indicates that the 23 kDa protein cross-reacts antigenically with anti-centrin antibodies. In addition, the 23 kDa protein displays calcium-induced changes in both electrophoretic and chromatographic behaviour, and contains calcium-binding domains that conform to the EF-hand structure, as known for centrin. Based on these observations, we conclude that a calcium-binding protein with major similarities to centrin occurs in the myonemes of E. maggii. We postulate that this protein plays an essential role in myoneme-mediated retraction of the ciliature.

  7. 76 FR 2431 - New Mexico Disaster #NM-00016

    Science.gov (United States)

    2011-01-13

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 12320 and 12321] New Mexico Disaster NM-00016... Presidential declaration of a major disaster for Public Assistance Only for the State of New Mexico (FEMA-1936... INFORMATION: The notice of the President's major disaster declaration for Private Non-Profit organizations in...

  8. 308-nm excimer lamp for the treatment of alopecia areata: Clinical trial on 16 cases

    Directory of Open Access Journals (Sweden)

    Akiko Ohtsuki

    2013-01-01

    Full Text Available Background: Alopecia areata (AA is considered as a T-cell mediated autoimmune disorder. The 308-nm excimer laser is thought to be capable of inducing T-cell apoptosis in vitro, suggesting that the 308-nm excimer lamp (not laser might be effective for the treatment of AA. We examined the effectiveness of the 308-nm excimer lamp for treating AA. Materials and Methods: We treated 16 patients with single AA and multiple AA (MAA. The lesions were irradiated with a 308-nm excimer lamp at 2-week intervals. Results: Hair regrowth was observed in 14 patients. Among them, 10 patients showed more than 50% hair re-growth. Our results suggested that the 308-nm excimer lamp system is effective and safe for the treatment of single AA and MAA. Conclusion: Our results suggest that the 308-nm excimer lamp is a good therapeutic alternative without serious side effect for treating AA.

  9. Photoluminescence and electroluminescence of a novel green-yellow emitting material-5,6-Bis-[4-(naphthalene-1-yl-phenyl-amino)-phenyl] -pyrazine-2,3-dicarbonitrile

    International Nuclear Information System (INIS)

    Chew Siewling; Wang Pengfei; Hong Zirou; Kwong, H.L.; Tang Jianxin; Sun Shiling; Lee, C.S.; Lee, S.-T.

    2007-01-01

    A new compound with intramolecular charge transfer (ICT) property-5,6-Bis-[4-(naphthalene-1-yl-phenyl-amino)-phenyl] -pyrazine-2,3-dicarbonitrile(BNPPDC) was synthesized. The new compound was strongly fluorescent in non-polar and moderately polar solvents, as well as in thin solid film. The absorption and emission maxima shifted to longer wavelength with increasing solvent polarity. The fluorescence quantum yield also increased with increasing solvent polarity from non-polar to moderately polar solvents, then decreased with further increase of solvent polarity. This indicates both 'positive' and 'negative' solvatokinetic effects co-existed. Using this material as hole-transporting emitter and host emitter, we fabricated two electroluminescent (EL) devices with structures of A (ITO/BNPPDC (45 nm)/1,3,5-tris(N-phenylbenzimidazol-2-yl)benzene (TPBI) (45 nm)/Mg:Ag (200 nm) and B (ITO/N,N'-diphenyl-N,N'-bis-(3-methylphenyl) (1,1'-diphenyl)4,4'-diamine (TPD) (50 nm)/BNPPDC (20 nm)/1,3,5-tris(N-phenylbenzimidazol-2-yl)benzene (TPBI) (45 nm)/Mg:Ag (200 nm). The devices showed green-yellow EL emission with good efficiency and high brightness. For example, the device A exhibited a high brightness of 17400 cd/m 2 at a driving voltage of 11 V and a very low turn-on voltage (2.9 V), as well as a maximum luminous efficiency 3.61 cd/A. The device B showed a similar performance with a high brightness of 12650 cd/m 2 at a driving voltage of 13 V and a maximum luminous efficiency 3.62 cd/A. In addition, the EL devices using BNPPDC as a host and 4-(dicyanomethylene)-2-t-butyl-6-(1,1,7,7-tetramethyljulolidyl-9-enyl) -4H-pyran (DCJTB) as a dopant (configuration: ITO/TPD (60 nm)/BNPPDC:DCJTB (2%) (30 nm)/TPBI (35 nm)/Mg:Ag (200 nm)) showed a good performance with a brightness of 150 cd/m 2 at 4.5 V, a maximum brightness of 12600 cd/m 2 at 11.5 V, and a maximum luminous efficiency of 3.30 cd/A

  10. Photoluminescence and electroluminescence of a novel green-yellow emitting material-5,6-Bis-[4-(naphthalene-1-yl-phenyl-amino)-phenyl] -pyrazine-2,3-dicarbonitrile

    Energy Technology Data Exchange (ETDEWEB)

    Chew Siewling [Center of Super-Diamond and Advanced Films (COSDAF) and Department of Physics and Materials Science, City University of Hong Kong, Hong Kong (China); Wang Pengfei [Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100101 (China)]. E-mail: wangpf@mail.ipc.ac.cn; Hong Zirou [Center of Super-Diamond and Advanced Films (COSDAF) and Department of Physics and Materials Science, City University of Hong Kong, Hong Kong (China); Kwong, H.L. [Department of Biology and Chemistry, City University of Hong Kong, Hong Kong (China); Tang Jianxin [Center of Super-Diamond and Advanced Films (COSDAF) and Department of Physics and Materials Science, City University of Hong Kong, Hong Kong (China); Sun Shiling [Center of Super-Diamond and Advanced Films (COSDAF) and Department of Physics and Materials Science, City University of Hong Kong, Hong Kong (China); Lee, C.S. [Center of Super-Diamond and Advanced Films (COSDAF) and Department of Physics and Materials Science, City University of Hong Kong, Hong Kong (China)]. E-mail: apcslee@cityu.edu.hk; Lee, S.-T. [Center of Super-Diamond and Advanced Films (COSDAF) and Department of Physics and Materials Science, City University of Hong Kong, Hong Kong (China)]. E-mail: apannale@cityu.edu.hk

    2007-06-15

    A new compound with intramolecular charge transfer (ICT) property-5,6-Bis-[4-(naphthalene-1-yl-phenyl-amino)-phenyl] -pyrazine-2,3-dicarbonitrile(BNPPDC) was synthesized. The new compound was strongly fluorescent in non-polar and moderately polar solvents, as well as in thin solid film. The absorption and emission maxima shifted to longer wavelength with increasing solvent polarity. The fluorescence quantum yield also increased with increasing solvent polarity from non-polar to moderately polar solvents, then decreased with further increase of solvent polarity. This indicates both 'positive' and 'negative' solvatokinetic effects co-existed. Using this material as hole-transporting emitter and host emitter, we fabricated two electroluminescent (EL) devices with structures of A (ITO/BNPPDC (45 nm)/1,3,5-tris(N-phenylbenzimidazol-2-yl)benzene (TPBI) (45 nm)/Mg:Ag (200 nm) and B (ITO/N,N'-diphenyl-N,N'-bis-(3-methylphenyl) (1,1'-diphenyl)4,4'-diamine (TPD) (50 nm)/BNPPDC (20 nm)/1,3,5-tris(N-phenylbenzimidazol-2-yl)benzene (TPBI) (45 nm)/Mg:Ag (200 nm). The devices showed green-yellow EL emission with good efficiency and high brightness. For example, the device A exhibited a high brightness of 17400 cd/m{sup 2} at a driving voltage of 11 V and a very low turn-on voltage (2.9 V), as well as a maximum luminous efficiency 3.61 cd/A. The device B showed a similar performance with a high brightness of 12650 cd/m{sup 2} at a driving voltage of 13 V and a maximum luminous efficiency 3.62 cd/A. In addition, the EL devices using BNPPDC as a host and 4-(dicyanomethylene)-2-t-butyl-6-(1,1,7,7-tetramethyljulolidyl-9-enyl) -4H-pyran (DCJTB) as a dopant (configuration: ITO/TPD (60 nm)/BNPPDC:DCJTB (2%) (30 nm)/TPBI (35 nm)/Mg:Ag (200 nm)) showed a good performance with a brightness of 150 cd/m{sup 2} at 4.5 V, a maximum brightness of 12600 cd/m{sup 2} at 11.5 V, and a maximum luminous efficiency of 3.30 cd/A.

  11. La2/3Sr1/3MnO3-La0.1Bi0.9MnO3 heterostructures for spin filtering

    Science.gov (United States)

    Gajek, M.; Bibes, M.; Varela, M.; Fontcuberta, J.; Herranz, G.; Fusil, S.; Bouzehouane, K.; Barthélémy, A.; Fert, A.

    2006-04-01

    We have grown heterostructures associating half-metallic La2/3Sr1/3MnO3 (LSMO) bottom electrodes and ferromagnetic La0.1Bi0.9MnO3 (LBMO) tunnel barriers. The layers in the heterostructures have good structural properties and top LBMO films (4 nm thick) have a very low roughness when deposited onto LSMO/SrTiO3(1.6 nm) templates. The LBMO films show an insulating behavior and a ferromagnetic character that are both preserved down to very low thicknesses. They are thus suitable for being used as tunnel barriers. Spin-dependent transport measurements performed on tunnel junctions defined from LSMO/SrTiO3/LBMO/Au samples show a magnetoresistance of up to ~90% at low temperature and bias. This evidences a spin-filtering effect by the LBMO layer, with a spin-filtering efficiency of ~35%.

  12. 7 CFR 1230.23 - Research.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Research. 1230.23 Section 1230.23 Agriculture... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE PORK PROMOTION, RESEARCH, AND CONSUMER INFORMATION Pork Promotion, Research, and Consumer Information Order Definitions § 1230.23...

  13. Biological activity and binding of estradiol to SK-Mel 23 human melanoma cells

    Directory of Open Access Journals (Sweden)

    Sarti M.S.M.V.

    2004-01-01

    Full Text Available Patients expressing estradiol receptors in melanoma cells have been reported to have a better prognosis. We therefore decided to investigate the in vitro effects of ß-estradiol and tamoxifen on the growth and tyrosinase activity of SK-Mel 23 human melanoma cells. Twenty-four-hour treatment with 0.4 nM ß-estradiol inhibited cell proliferation in 30% (0.70 ± 0.03 x 10(5 cells and increased tyrosinase activity in 50% (7130.5 ± 376.5 cpm/10(5 cells, as compared to untreated cells (1.0 ± 0.05 x 10(5 cells and 4769 ± 25.5 cpm/10(5 cells, respectively. Both responses were completely (100% blocked by 1 µM tamoxifen. Higher concentrations (up to 1.6 nM or longer treatments (up to 72 h did not result in a larger effect of the hormone on proliferation or tyrosinase activity. Competition binding assays demonstrated the presence of binding sites to [2,4,6,7-³H]-ß-estradiol, and that the tritiated analogue was displaced by the unlabeled hormone (1 nM to 100 µM, Kd = 0.14 µM, maximal displacement of 93% or by 10 µM tamoxifen (displacement of 60%. ß-estradiol also increased the phosphorylated state of two proteins of 16 and 46 kDa, after 4-h treatment, as determined by Western blot. The absorbance of each band was 1.9- and 4-fold the controls, respectively, as determined with Image-Pro Plus software. Shorter incubation periods with ß-estradiol did not enhance phosporylation; after 6-h treatment with the hormone, the two proteins returned to the control phosphorylation levels. The growth inhibition promoted by estradiol may explain the better prognosis of melanoma-bearing women as compared to men, and open new perspectives for drug therapy.

  14. Minimum K_2,3-saturated Graphs

    OpenAIRE

    Chen, Ya-Chen

    2010-01-01

    A graph is K_{2,3}-saturated if it has no subgraph isomorphic to K_{2,3}, but does contain a K_{2,3} after the addition of any new edge. We prove that the minimum number of edges in a K_{2,3}-saturated graph on n >= 5 vertices is sat(n, K_{2,3}) = 2n - 3.

  15. Diode-pumped CW frequency-doubled Nd:CNGG-BiBO blue laser at 468 nm

    International Nuclear Information System (INIS)

    Lü, Y F; Xia, J; Lin, J Q; Gao, X; Dong, Y; Xu, L J; Sun, G C; Zhao, Z M; Tan, Y; Chen, J F; Liu, Z X; Li, C L; Cai, H X; Liu, Z T; Ma, Z Y; Ning, G B

    2011-01-01

    Efficient and compact blue laser output at 468 nm is generated by intracavity frequency doubling of a continuous-wave (CW) diode-pumped Nd:CNGG laser at 935 nm. With 17.8 W of diode pump power and the frequency-doubling crystal BiB 3 O 6 (BiBO), a maximum output power of 490 mW in the blue spectral range at 468 nm has been achieved, corresponding to an optical-to-optical conversion efficiency of 2.8%; the output power stability over 4 h is better than 2.6%. To the best of our knowledge, this is first work on intracavity frequency doubling of a diode pumped Nd:CNGG laser at 935 nm

  16. Ablation of the Galnt3 Gene Leads to Low-Circulating Intact Fibroblast Growth Factor 23 (Fgf23) Concentrations and Hyperphosphatemia Despite Increased Fgf23 Expression

    OpenAIRE

    Ichikawa, Shoji; Sorenson, Andrea H.; Austin, Anthony M.; Mackenzie, Donald S.; Fritz, Timothy A.; Moh, Akira; Hui, Siu L.; Econs, Michael J.

    2009-01-01

    Familial tumoral calcinosis is characterized by ectopic calcifications and hyperphosphatemia. The disease is caused by inactivating mutations in fibroblast growth factor 23 (FGF23), Klotho (KL), and uridine diphosphate-N-acetyl-α-D-galactosamine:polypeptide N-acetylgalactosaminyltransferase 3 (GALNT3). In vitro studies indicate that GALNT3 O-glycosylates a phosphaturic hormone, FGF23, and prevents its proteolytic processing, thereby allowing secretion of intact FGF23. In this study we generat...

  17. 7 CFR 1219.23 - Research.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Research. 1219.23 Section 1219.23 Agriculture... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE HASS AVOCADO PROMOTION, RESEARCH, AND INFORMATION Hass Avocado Promotion, Research, and Information Order Definitions § 1219.23 Research...

  18. 40 CFR 406.23 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 406.23 Section 406.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GRAIN MILLS POINT SOURCE CATEGORY Corn Dry Milling Subcategory § 406.23 [Reserved] ...

  19. 7 CFR 1216.23 - Promotion.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Promotion. 1216.23 Section 1216.23 Agriculture... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE PEANUT PROMOTION, RESEARCH, AND INFORMATION ORDER Peanut Promotion, Research, and Information Order Definitions § 1216.23 Promotion. Promotion...

  20. Design and synthesis of potent, orally-active DGAT-1 inhibitors containing a dioxino[2,3-d]pyrimidine core.

    Science.gov (United States)

    Dow, Robert L; Andrews, Melissa; Aspnes, Gary E; Balan, Gayatri; Michael Gibbs, E; Guzman-Perez, Angel; Karki, Kapil; Laperle, Jennifer L; Li, Jian-Cheng; Litchfield, John; Munchhof, Michael J; Perreault, Christian; Patel, Leena

    2011-10-15

    A novel series of potent DGAT-1 inhibitors was developed originating from the lactam-based clinical candidate PF-04620110. Incorporation of a dioxino[2,3-d]pyrimidine-based core afforded good alignment of pharmacophore features and resulted in improved passive permeability. Development of an efficient, homochiral synthesis of these targets facilitated confirmation of predictions regarding the stereochemical-dependence of DGAT-1 inhibition for this series. Compound 10 was shown to be a potent inhibitor of human DGAT-1 (10 nM) and to suppress triglyceride synthesis at oral doses of <3mg/kg. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Enzymatic degradation of cyclic 2,3-diphosphoglycerate to 2,3-diphosphoglycerate in Methanobacterium thermoautotrophicum.

    Science.gov (United States)

    Sastry, M V; Robertson, D E; Moynihan, J A; Roberts, M F

    1992-03-24

    2,3-Diphosphoglycerate (2,3-DPG) has been found to be the product of the enzymatic degradation of cyclic 2,3-diphosphoglycerate (cDPG) in the archaebacterium Methanobacterium thermoautotrophicum delta H. Although 2,3-DPG has not previously been detected as a major soluble component of M. thermoautotrophicum, large pools accumulated at an incubation temperature of 50 degrees C (below the optimum growth temperature of 62 degrees C). Under these conditions, cellular activity was significantly decreased; a return of the culture to the optimum growth temperature restored the 2,3-DPG pool back to original low levels and caused steady-state cDPG levels to increase again. While 13CO2-pulse/12CO2-chase experiments at 50 degrees C showed that the cDPG turned over, the appearance of 2,3-DPG at NMR-visible concentrations required at least 10 h. Production of 2,3-DPG in vivo was prevented by exposure of the cells to O2. The enzyme responsible for this hydrolysis of cDPG was purified by affinity chromatography and appears to be a 33-kDa protein. Activity was detected in the presence of oxygen and was enhanced by a solution of 1 M KCl, 25 mM MgCl2, and dithiothreitol. Both Km and Vmax have been determined at 37 degrees C; kinetics also indicate that in vitro the product, 2,3-DPG, is an inhibitor of cDPG hydrolysis. These findings are discussed in view of a proposed role for cDPG in methanogens.

  2. All-dry resist processes for 193-nm lithography

    Science.gov (United States)

    Horn, Mark W.; Maxwell, Brian E.; Kunz, Roderick R.; Hibbs, Michael S.; Eriksen, Lynn M.; Palmateer, Susan C.; Forte, Anthony R.

    1995-06-01

    We report on two different all-dry resist schemes for 193-nm lithography, one negative tone and one positive tone. Our negative tone resist is an extension of our initial work on all-dry photoresists. This scheme employs a bilayer in which the imaging layer is formed by plasma enhanced chemical vapor deposition (PECVD) from tetramethylsilane (TMS) and deposited onto PECVD carbon-based planarizing layers. Figure 1 shows SEMs of dark field and light field octagons patterned in projection on Lincoln Laboratory's 0.5-NA 193-nm Micrascan system. These 0.225-micrometers and 0.200-micrometers line and space features were obtained at a dose of approximately 58 mJ/cm2. Dry development of the exposed resist was accomplished using Cl2 chemistry in a helicon high-ion-density etching tool. Pattern transfer was performed in the helicon tool with oxygen-based chemistries. Recently, we have also developed an all-dry positive-tone silylation photoresist. This photoresist is a PECVD carbon-based polymer which is crosslinked by 193-nm exposure, enabling selective silylation similar to that initially reported by Hartney et al., with spin-applied polymers. In those polymers, for example polyvinylphenol, the silylation site concentration is fixed by the hydroxyl groups on the polymer precursors, thus limiting the silicon uptake per unit volume. With PECVD polymers, the total concentration of silylation sites and their depth can be tailored by varying plasma species as a function of time during the deposition. This affords the possibility of greater silicon uptake per unit volume and better depth control of the silylation profile. Figure 2 shows a SEM of 0.5-micrometers features patterned in plasma deposited silylation resist.

  3. 7 CFR 29.23 - Tobacco.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Tobacco. 29.23 Section 29.23 Agriculture Regulations... Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS TOBACCO INSPECTION Regulations Definitions § 29.23 Tobacco. Tobacco in its unmanufactured forms as it appears between...

  4. 48 CFR 23.502 - Authority.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Authority. 23.502 Section 23.502 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION SOCIOECONOMIC PROGRAMS... WORKPLACE Drug-Free Workplace 23.502 Authority. Drug-Free Workplace Act of 1988 (Pub. L. 100-690). ...

  5. 48 CFR 23.801 - Authorities.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Authorities. 23.801 Section 23.801 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION SOCIOECONOMIC... DRUG-FREE WORKPLACE Ozone-Depleting Substances 23.801 Authorities. (a) Title VI of the Clean Air Act...

  6. A diode-end-pumped Nd:GYSGG continuous wave laser at 1104 nm

    International Nuclear Information System (INIS)

    Shen, B J; Kang, H X; Zhang, C G; Chen, P; Gao, R L; Liang, J; Gao, H J; Zhang, Q L; Sun, D L; Yin, S T; Luo, J Q

    2013-01-01

    The continuous wave (CW) laser performance of Nd:GYSGG at 1104 nm is investigated for the first time, to our knowledge. A CW laser output power of 4.7 W is obtained when the pump power of the 808 nm fiber coupled laser diode is 19.1 W, corresponding to a conversion efficiency of 24.6% and slope efficiency of 37%. (paper)

  7. 300 nm bandwidth adiabatic SOI polarization splitter-rotators exploiting continuous symmetry breaking.

    Science.gov (United States)

    Socci, Luciano; Sorianello, Vito; Romagnoli, Marco

    2015-07-27

    Adiabatic polarization splitter-rotators are investigated exploiting continuous symmetry breaking thereby achieving significant device size and losses reduction in a single mask fabrication process for both SOI channel and ridge waveguides. A crosstalk lower than -25 dB is expected over 300nm bandwidth, making the device suitable for full grid CWDM and diplexer/triplexer FTTH applications at 1310, 1490 and 1550nm.

  8. Future directions in 980-nm pump lasers: submarine deployment to low-cost watt-class terrestrial pumps

    Science.gov (United States)

    Gulgazov, Vadim N.; Jackson, Gordon S.; Lascola, Kevin M.; Major, Jo S.; Parke, Ross; Richard, Tim; Rossin, Victor V.; Zhang, Kai

    1999-09-01

    The demands of global bandwidth and distribution are rising rapidly as Internet usage grows. This fundamentally means that more photons are flowing within optical cables. While transmitting sources launches some optical power, the majority of the optical power that is present within modern telecommunication systems originates from optical amplifiers. In addition, modern optical amplifiers offer flat optical gain over broad wavelength bands, thus making possible dense wavelength de-multiplexing (DWDM) systems. Optical amplifier performance, and by extension the performance of the laser pumps that drive them, is central to the future growth of both optical transmission and distribution systems. Erbium-doped amplifiers currently dominate optical amplifier usage. These amplifiers absorb pump light at 980 nm and/or 1480 nm, and achieve gain at wavelengths around 1550 nm. 980 nm pumps achieve better noise figures and are therefore used for the amplification of small signals. Due to the quantum defect, 1480 nm lasers deliver more signal photon per incident photon. In addition, 1480 nm lasers are less expensive than 980 nm lasers. Thus, 1480 nm pump lasers are used for amplification in situations where noise is not critical. The combination of these traits leads to the situation where many amplifiers contain 980 nm lasers to pump the input section of the Er- doped fiber with 1480 nm lasers being used to pump the latter section of Er fiber. This can be thought of as using 980 nm lasers to power an optical pre-amplifier with the power amplification function being pump with 1480 nm radiation. This paper will focus on 980 nm pump lasers and the impact that advances in 980 nm pump technology will have on optical amplification systems. Currently, 980 nm technology is rapidly advancing in two areas, power and reliability. Improving reliability is becoming increasingly important as amplifiers move towards employing more pump lasers and using these pump lasers without redundancy

  9. 8 nm nanodiamonds as markers for 2 photon excited luminescent microscopy

    International Nuclear Information System (INIS)

    Kharin, A; Rogov, A; Bonacina, L; Geloen, A; Lysenko, V

    2016-01-01

    Structural and luminescent properties of stable suspensions of fluorescent nanodiamonds were investigated. Measurement of the effective hydrodynamic radius yields particles less than 30 nm diameter, while the TEM measurements made on the same particles shows average diameter about 8 nm. It was found that NDs have relatively low toxicity. Upon incubation, 3T3-L1 cells spontaneously take up nanodiamonds that uniformly distribute in cells cytoplasm. The possibility of fluorescent imaging using both single ore two-photon excitation was shown. (paper)

  10. Compact 2100 nm laser diode module for next-generation DIRCM

    Science.gov (United States)

    Dvinelis, Edgaras; Greibus, Mindaugas; TrinkÅ«nas, Augustinas; NaujokaitÄ--, Greta; Vizbaras, Augustinas; Vizbaras, Dominykas; Vizbaras, Kristijonas

    2017-10-01

    Compact high-power 2100 nm laser diode module for next-generation directional infrared countermeasure (DIRCM) systems is presented. Next-generation DIRCM systems require compact, light-weight and robust laser modules which could provide intense IR light emission capable of disrupting the tracking sensor of heat-seeking missile. Currently used solid-state and fiber laser solutions for mid-IR band are bulky and heavy making them difficult to implement in smaller form-factor DIRCM systems. Recent development of GaSb laser diode technology greatly improved optical output powers and efficiencies of laser diodes working in 1900 - 2450 nm band [1] while also maintaining very attractive size, weight, power consumption and cost characteristics. 2100 nm laser diode module presented in this work performance is based on high-efficiency broad emitting area GaSb laser diode technology. Each laser diode emitter is able to provide 1 W of CW output optical power with working point efficiency up to 20% at temperature of 20 °C. For output beam collimation custom designed fast-axis collimator and slow-axis collimator lenses were used. These lenses were actively aligned and attached using UV epoxy curing. Total 2 emitters stacked vertically were used in 2100 nm laser diode module. Final optical output power of the module goes up to 2 W at temperature of 20 °C. Total dimensions of the laser diode module are 35 x 25 x 16 mm (L x W x H) with a weight of 28 grams. Finally output beam is bore-sighted to mechanical axes of the module housing allowing for easy integration into next-generation DIRCM systems.

  11. 32 CFR 776.23 - Communication.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Communication. 776.23 Section 776.23 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY MISCELLANEOUS RULES PROFESSIONAL CONDUCT... Professional Conduct § 776.23 Communication. (a) Communication: (1) A covered attorney shall keep a client...

  12. 28 CFR 23.1 - Purpose.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Purpose. 23.1 Section 23.1 Judicial Administration DEPARTMENT OF JUSTICE CRIMINAL INTELLIGENCE SYSTEMS OPERATING POLICIES § 23.1 Purpose. The purpose...-647), are utilized in conformance with the privacy and constitutional rights of individuals. ...

  13. 24 CFR 882.123 - Conversion of Section 23 Units to Section 8 and Section 23 monitoring.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Conversion of Section 23 Units to... Applicability, Scope and Basic Policies § 882.123 Conversion of Section 23 Units to Section 8 and Section 23 monitoring. (a)-(d) [Reserved] (e) Section 23 policies for units planned for conversion on or before...

  14. 78 FR 66982 - New Mexico Disaster #NM-00035

    Science.gov (United States)

    2013-11-07

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 13809 and 13810] New Mexico Disaster NM-00035... declaration of a major disaster for Public Assistance Only for the State of New Mexico (FEMA- 4152-DR), dated... INFORMATION: Notice is hereby given that as a result of the President's major disaster declaration on 10/29...

  15. Laser at 532 nm by intracavity frequency-doubling in BBO

    Science.gov (United States)

    Yuan, Xiandan; Wang, Jinsong; Chen, Yongqi; Wu, Yulong; Qi, Yunfei; Sun, Meijiao; Wang, Qi

    2017-06-01

    A simple and compact linear resonator green laser at 532 nm is generated by intracavity frequency-doubling of a diode-side-pumped acousto-optically (AO) Q-switched Nd:YAG laser at 1064 nm. Two acousto-optic Q-switches were placed orthogonally with each other to improve the hold-off capacity. As high as 214 W of continuous-wave (CW) and 154 W of quasi-continuous-wave (QCW) output power at 1064 nm were obtained when the pumping power was 1598 W. The type I phase-matched BBO crystal was used as the nonlinear medium in the second harmonic generation. A green laser with an average output power of 37 W was obtained at a repetition rate of 20 kHz and a pulse width of 54 ns, which corresponds to pulse energy of 1.85 mJ per pulse and a peak power 34.26 kW, respectively. Project supported by the Beijing Engineering Technology Research Center of All-Solid-State Lasers Advanced Manufacturing, the National High Technology Research and Development Program of China (No. 2014AA032607), and the National Natural Science Foundation of China (Nos. 61404135, 61405186, 61308032, 61308033).

  16. Advanced CMOS device technologies for 45 nm node and below

    Directory of Open Access Journals (Sweden)

    A. Veloso, T. Hoffmann, A. Lauwers, H. Yu, S. Severi, E. Augendre, S. Kubicek, P. Verheyen, N. Collaert, P. Absil, M. Jurczak and S. Biesemans

    2007-01-01

    Full Text Available We review and discuss the latest developments and technology options for 45 nm node and below, with scaled planar bulk MOSFETs and MuGFETs as emerging devices. One of the main metal gate (MG candidates for scaled CMOS technologies are fully silicided (FUSI gates. In this work, by means of a selective and controlled poly etch-back integration process, dual work-function Ni-based FUSI/HfSiON CMOS circuits with record ring oscillator performance (high-VT are reported (17 ps at VDD=1.1 V and 20 pA/μm Ioff, meeting the ITRS 45 nm node requirement for low-power (LP CMOS. Compatibility of FUSI and other MG with known stress boosters like stressed CESL (contact-etch-stop-layer with high intrinsic stress or embedded SiGe in the pMOS S/D regions is validated. To obtain MuGFET devices that are competitive, as compared to conventional planar bulk devices, and that meet the stringent drive and leakage current requirements for the 32 nm node and beyond, higher channel mobilities are required. Results obtained by several strain engineering methods are presented here.

  17. Keratin23 (KRT23 knockdown decreases proliferation and affects the DNA damage response of colon cancer cells.

    Directory of Open Access Journals (Sweden)

    Karin Birkenkamp-Demtröder

    Full Text Available Keratin 23 (KRT23 is strongly expressed in colon adenocarcinomas but absent in normal colon mucosa. Array based methylation profiling of 40 colon samples showed that the promoter of KRT23 was methylated in normal colon mucosa, while hypomethylated in most adenocarcinomas. Promoter methylation correlated with absent expression, while increased KRT23 expression in tumor samples correlated with promoter hypomethylation, as confirmed by bisulfite sequencing. Demethylation induced KRT23 expression in vitro. Expression profiling of shRNA mediated stable KRT23 knockdown in colon cancer cell lines showed that KRT23 depletion affected molecules of the cell cycle and DNA replication, recombination and repair. In vitro analyses confirmed that KRT23 depletion significantly decreased the cellular proliferation of SW948 and LS1034 cells and markedly decreased the expression of genes involved in DNA damage response, mainly molecules of the double strand break repair homologous recombination pathway. KRT23 knockdown decreased the transcript and protein expression of key molecules as e.g. MRE11A, E2F1, RAD51 and BRCA1. Knockdown of KRT23 rendered colon cancer cells more sensitive to irradiation and reduced proliferation of the KRT23 depleted cells compared to irradiated control cells.

  18. Photodissociation of the acetone cation at 355 nm using the velocity imaging technique

    Science.gov (United States)

    Jackson, William M.; Xu, Dadong

    2000-09-01

    Photodissociation of acetone cations, CH3COCH3+, at 355 nm has been studied by means of the ion velocity imaging technique. Acetone cations are produced via direct photoionization of a supersonic beam of acetone at 118 nm generated by frequency tripling the 355 nm laser. Only the acetyl cation, CH3CO+, could be detected as a dissociation product in the time-of-flight mass spectrometer. The acetyl ion signal depends upon the fifth power of the 355 nm laser energy, while the acetone ion signal depends upon the third power. This suggests that the fragment ion is produced via two-photon absorption of 355 nm photons by the acetone cation. The total translational energy distribution and angular distribution of acetyl cation were derived from the 2D images of CH3CO+ for the reaction CH3COCH3++2hν355nm→CH3CO++CH3*. The translational energy distribution suggests that methyl radicals are produced in two electronically excited states, the Rydberg 3s 1 2A1' and the valence 1 2A″ states. The anisotropy parameter β shows that the Rydberg state is formed via a perpendicular excitation and the valence state via a parallel transition.

  19. Electron multi-beam technology for mask and wafer writing at 0.1nm address grid

    Science.gov (United States)

    Platzgummer, Elmar; Klein, Christof; Loeschner, Hans

    2013-03-01

    An overview of electron beam tool configurations is provided. The adoption of multi-beam writing is mandatory in order to fulfill industrial needs for 11nm HP nodes and below. IMS Nanofabrication realized a 50keV electron multibeam proof-of-concept (POC) tool confirming writing principles with 0.1nm address grid and lithography performance capability. The new architecture will be introduced for mask writing at first, but has also the potential for 1xmask (master template) and direct wafer writing. The POC system achieves the predicted 5nm 1sigma blur across the 82μm x 82μm array of 512 x 512 (262,144) programmable 20nm beams. 24nm HP has been demonstrated and complex patterns have been written in scanning stripe exposure mode. The first production worthy system for the 11nm HP mask node is scheduled for 2014 (Alpha), 2015 (Beta) and 1st generation HVM mask writer tools in 2016. Implementing a multi-axis column configuration, 50x / 100x productivity enhancements are possible for direct 300mm / 450mm wafer writing.

  20. Sub-5 nm, globally aligned graphene nanoribbons on Ge(001)

    Energy Technology Data Exchange (ETDEWEB)

    Kiraly, Brian; Mannix, Andrew J. [Center for Nanoscale Materials, Argonne National Laboratory, 9700 South Cass Avenue, Building 440, Argonne, Illinois 60439 (United States); Department of Materials Science and Engineering, Northwestern University, 2220 Campus Drive, Evanston, Illinois 60208 (United States); Jacobberger, Robert M.; Arnold, Michael S. [Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States); Fisher, Brandon L.; Guisinger, Nathan P., E-mail: nguisinger@anl.gov, E-mail: m-hersam@northwestern.edu [Center for Nanoscale Materials, Argonne National Laboratory, 9700 South Cass Avenue, Building 440, Argonne, Illinois 60439 (United States); Hersam, Mark C., E-mail: nguisinger@anl.gov, E-mail: m-hersam@northwestern.edu [Department of Materials Science and Engineering, Northwestern University, 2220 Campus Drive, Evanston, Illinois 60208 (United States); Department of Chemistry, Northwestern University, 2220 Campus Drive, Evanston, Illinois 60208 (United States)

    2016-05-23

    Graphene nanoribbons (GNRs) hold great promise for future electronics because of their edge and width dependent electronic bandgaps and exceptional transport properties. While significant progress toward GNR devices has been made, the field has been limited by difficulties achieving narrow widths, global alignment, and atomically pristine GNR edges on technologically relevant substrates. A recent advance has challenged these limits by using Ge(001) substrates to direct the bottom-up growth of GNRs with nearly pristine armchair edges and widths near ∼10 nm via atmospheric pressure chemical vapor deposition. In this work, the growth of GNRs on Ge(001) is extended to ultra-high vacuum conditions, resulting in the realization of GNRs with widths narrower than 5 nm. Armchair graphene nanoribbons oriented along Ge 〈110〉 surface directions are achieved with excellent width control and relatively large bandgaps. The bandgap magnitude and electronic uniformity of these sub-5 nm GNRs are well-suited for emerging nanoelectronic applications.

  1. Size dependent compressibility of nano-ceria: Minimum near 33 nm

    International Nuclear Information System (INIS)

    Rodenbough, Philip P.; Song, Junhua; Chan, Siu-Wai; Walker, David; Clark, Simon M.; Kalkan, Bora

    2015-01-01

    We report the crystallite-size-dependency of the compressibility of nanoceria under hydrostatic pressure for a wide variety of crystallite diameters and comment on the size-based trends indicating an extremum near 33 nm. Uniform nano-crystals of ceria were synthesized by basic precipitation from cerium (III) nitrate. Size-control was achieved by adjusting mixing time and, for larger particles, a subsequent annealing temperature. The nano-crystals were characterized by transmission electron microscopy and standard ambient x-ray diffraction (XRD). Compressibility, or its reciprocal, bulk modulus, was measured with high-pressure XRD at LBL-ALS, using helium, neon, or argon as the pressure-transmitting medium for all samples. As crystallite size decreased below 100 nm, the bulk modulus first increased, and then decreased, achieving a maximum near a crystallite diameter of 33 nm. We review earlier work and examine several possible explanations for the peaking of bulk modulus at an intermediate crystallite size

  2. Size dependent compressibility of nano-ceria: Minimum near 33 nm

    Energy Technology Data Exchange (ETDEWEB)

    Rodenbough, Philip P. [Department of Applied Physics and Applied Mathematics, Materials Science and Engineering Program, Columbia University, New York, New York 10027 (United States); Chemistry Department, Columbia University, New York, New York 10027 (United States); Song, Junhua; Chan, Siu-Wai, E-mail: sc174@columbia.edu [Department of Applied Physics and Applied Mathematics, Materials Science and Engineering Program, Columbia University, New York, New York 10027 (United States); Walker, David [Department of Earth and Environmental Sciences, Lamont-Doherty Earth Observatory, Columbia University, Palisades, New York 10964 (United States); Clark, Simon M. [ARC Center of Excellence for Core to Crust Fluid Systems and Department of Earth and Planetary Sciences, Macquarie University, Sydney, New South Wales 2019, Australia and The Bragg Institute, Australian Nuclear Science and Technology Organisation, Kirrawee DC, New South Wales 2232 (Australia); Kalkan, Bora [Department of Physics Engineering, Hacettepe University, 06800 Beytepe, Ankara (Turkey)

    2015-04-20

    We report the crystallite-size-dependency of the compressibility of nanoceria under hydrostatic pressure for a wide variety of crystallite diameters and comment on the size-based trends indicating an extremum near 33 nm. Uniform nano-crystals of ceria were synthesized by basic precipitation from cerium (III) nitrate. Size-control was achieved by adjusting mixing time and, for larger particles, a subsequent annealing temperature. The nano-crystals were characterized by transmission electron microscopy and standard ambient x-ray diffraction (XRD). Compressibility, or its reciprocal, bulk modulus, was measured with high-pressure XRD at LBL-ALS, using helium, neon, or argon as the pressure-transmitting medium for all samples. As crystallite size decreased below 100 nm, the bulk modulus first increased, and then decreased, achieving a maximum near a crystallite diameter of 33 nm. We review earlier work and examine several possible explanations for the peaking of bulk modulus at an intermediate crystallite size.

  3. 7 CFR 1425.23 - Reports.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Reports. 1425.23 Section 1425.23 Agriculture... AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS COOPERATIVE MARKETING ASSOCIATIONS § 1425.23 Reports. (a) CMA's shall annually provide CCC a report of all commodity deliveries involved in loans and LDP's by...

  4. 7 CFR 23.10 - Administration.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 1 2010-01-01 2010-01-01 false Administration. 23.10 Section 23.10 Agriculture Office of the Secretary of Agriculture STATE AND REGIONAL ANNUAL PLANS OF WORK Regional Program § 23.10 Administration. (a) The Regional Programs will be administered through four Regional Rural Development Centers...

  5. 28 CFR 23.2 - Background.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Background. 23.2 Section 23.2 Judicial Administration DEPARTMENT OF JUSTICE CRIMINAL INTELLIGENCE SYSTEMS OPERATING POLICIES § 23.2 Background. It is... potential threats to the privacy of individuals to whom such data relates, policy guidelines for Federally...

  6. Mutagenesis of mNeptune Red-Shifts Emission Spectrum to 681-685 nm.

    Science.gov (United States)

    Li, ZhaoYang; Zhang, ZhiPing; Bi, LiJun; Cui, ZongQiang; Deng, JiaoYu; Wang, DianBing; Zhang, Xian-En

    2016-01-01

    GFP-like fluorescent proteins with diverse emission wavelengths have been developed through mutagenesis, offering many possible choices in cellular and tissue imaging, such as multi-targets imaging, deep tissue imaging that require longer emission wavelength. Here, we utilized a combined approach of random mutation and structure-based rational design to develop new NIR fluorescent proteins on the basis of a far-red fluorescent protein, mNeptune (Ex/Em: 600/650 nm). We created a number of new monomeric NIR fluorescent proteins with the emission range of 681-685 nm, which exhibit the largest Stocks shifts (77-80 nm) compared to other fluorescent proteins. Among them, mNeptune681 and mNeptune684 exhibit more than 30 nm redshift in emission relative to mNeptune, owing to the major role of the extensive hydrogen-bond network around the chromophore and contributions of individual mutations to the observed redshift. Furthermore, the two variants still maintain monomeric state in solution, which is a trait crucial for their use as protein tags. In conclusion, our results suggest that there is untapped potential for developing fluorescent proteins with desired properties.

  7. Ultrathin Nanocrystalline Diamond Films with Silicon Vacancy Color Centers via Seeding by 2 nm Detonation Nanodiamonds.

    Science.gov (United States)

    Stehlik, Stepan; Varga, Marian; Stenclova, Pavla; Ondic, Lukas; Ledinsky, Martin; Pangrac, Jiri; Vanek, Ondrej; Lipov, Jan; Kromka, Alexander; Rezek, Bohuslav

    2017-11-08

    Color centers in diamonds have shown excellent potential for applications in quantum information processing, photonics, and biology. Here we report chemical vapor deposition (CVD) growth of nanocrystalline diamond (NCD) films as thin as 5-6 nm with photoluminescence (PL) from silicon-vacancy (SiV) centers at 739 nm. Instead of conventional 4-6 nm detonation nanodiamonds (DNDs), we prepared and employed hydrogenated 2 nm DNDs (zeta potential = +36 mV) to form extremely dense (∼1.3 × 10 13 cm -2 ), thin (2 ± 1 nm), and smooth (RMS roughness < 0.8 nm) nucleation layers on an Si/SiO x substrate, which enabled the CVD growth of such ultrathin NCD films in two different and complementary microwave (MW) CVD systems: (i) focused MW plasma with an ellipsoidal cavity resonator and (ii) pulsed MW plasma with a linear antenna arrangement. Analytical ultracentrifuge, infrared and Raman spectroscopies, atomic force microscopy, and scanning electron microscopy are used for detailed characterization of the 2 nm H-DNDs and the nucleation layer as well as the ultrathin NCD films. We also demonstrate on/off switching of the SiV center PL in the NCD films thinner than 10 nm, which is achieved by changing their surface chemistry.

  8. Keratin23 (KRT23) knockdown decreases proliferation and affects the DNA damage response of colon cancer cells

    DEFF Research Database (Denmark)

    Birkenkamp-Demtröder, Karin; Hahn, Stephan; Mansilla, Francisco

    2013-01-01

    correlated with absent expression, while increased KRT23 expression in tumor samples correlated with promoter hypomethylation, as confirmed by bisulfite sequencing. Demethylation induced KRT23 expression in vitro. Expression profiling of shRNA mediated stable KRT23 knockdown in colon cancer cell lines showed...... response, mainly molecules of the double strand break repair homologous recombination pathway. KRT23 knockdown decreased the transcript and protein expression of key molecules as e.g. MRE11A, E2F1, RAD51 and BRCA1. Knockdown of KRT23 rendered colon cancer cells more sensitive to irradiation and reduced......Keratin 23 (KRT23) is strongly expressed in colon adenocarcinomas but absent in normal colon mucosa. Array based methylation profiling of 40 colon samples showed that the promoter of KRT23 was methylated in normal colon mucosa, while hypomethylated in most adenocarcinomas. Promoter methylation...

  9. Preparation of sub 3 nm copper nanoparticles by microwave irradiation in the presence of triethylene tetramin

    Science.gov (United States)

    Tseng, Po-Hao; Wang, Yen-Zen; Hsieh, Tar-Hwa; Ho, Ko-Shan; Tsai, Cheng-Hsien; Chen, Kuan-Ting

    2018-02-01

    The preparation of sub 3 nm copper nanoparticles (CuNPs) in ethylene glycol (EG) using triethylene tetramine (TETA) as chelating and reducing agents via a rapid microwave (MW) irradiation is reported. The sub 3 nm CuNPs after MW irradiation are clearly seen from the electronic micrographs. The firm chelation of Cu2+ by TETA is illustrated by the dark blue color of Cu2+/TETA/EG solution and the redox reaction is confirmed by the appearance of red color of the mixtures. The optimal mole ratio of TETA/Cu 2+ is found to be 2.5/1 for preparing sub 3 nm CuNPs under the MW irradiation, operated at 800 W for 1 min. The plasmonic absorption λ max demonstrated in UV-vis spectra are found to close to 200 nm for sub 3 nm CuNPs, comparing to 500 ˜ 600 nm for regular, larger CuNPs. The extremely low Tm around 30 °C and the fusion/recrystallization sequence of sub 3 nm CuNPs can be directly measured by their differential scanning calorimetry thermograms.

  10. Approach to Exchange Bias Effect in La2/3Ca1/3MnO3/BiFeO3 and BiFeO3/ La2/3Ca1/3MnO3 Bilayers

    Science.gov (United States)

    Dominguez, Claribel; Ordonez, John; Diez, Sandra; Gomez, Maria; Guénon, Stefan; Schuller, Ivan

    2013-03-01

    We have grown bilayers of ferromagnetic La2/3Ca1/3MnO3 (LCMO) and multiferroic BiFeO3 (BFO) on (100) SrTiO3 (STO) substrates, by DC- and magnetron RF -sputtering technique, respectively, at high-oxygen pressures. We maintain constant the thickness of the layers (tBFO=72nm; tLCMO=80nm). Temperature dependence of the resistivity indicates that the MI-transition temperature of the manganite in the BFO/LCMO/STO is affected by the presence of the BFO layer in comparison with TMI for the single LCMO layer. Furthermore, temperature dependence of magnetization shows that the BFO/LCMO/STO bilayer has higher Curie temperature than that for LCMO/BFO/STO, indicating a strong structural dependence of the LCMO layer with magnetic response. The dependence of the magnetic moment with magnetic field after field cooling gives indication of the existence of Exchange Bias effect in the LCMO/BFO/STO bilayer. Isothermal loops also display dependence of the Exchange Bias magnitude with field cooling. This work has been supported by UNIVALLE Research Project CI 7864, and ``El Patrimonio Autónomo Fondo Nacional de Financiamiento para CT&I FJC,'' Contract RC - No. 275-2011, COLCIENCIAS-CENM, Colombia

  11. Raman Spectra and Bulk Modulus of Nanodiamond in a Size Interval of 2-5 nm.

    Science.gov (United States)

    Popov, Mikhail; Churkin, Valentin; Kirichenko, Alexey; Denisov, Viktor; Ovsyannikov, Danila; Kulnitskiy, Boris; Perezhogin, Igor; Aksenenkov, Viktor; Blank, Vladimir

    2017-10-10

    Nanodiamond in a 2-5-nm size interval (which is typical for an appearance of quantum confinement effect) show Raman spectra composed of 3 bands at 1325, 1600, and 1500 cm -1 (at the 458-nm laser excitation) which shifts to 1630 cm -1 at the 257-nm laser excitation. Contrary to sp 2 -bonded carbon, relative intensities of the bands do not depend on the 458- and 257-nm excitation wavelengths, and a halfwidth and the intensity of the 1600 cm -1 band does not change visibly under pressure at least up to 50 GPa. Bulk modulus of the 2-5-nm nanodiamond determined from the high-pressure study is around 560 GPa. Studied 2-5-nm nanodiamond was purified from contamination layers and dispersed in Si or NaCl.

  12. 45 CFR 99.23 - Discovery.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Discovery. 99.23 Section 99.23 Public Welfare... DEVELOPMENT FUND Hearing Procedures § 99.23 Discovery. The Department, the Lead Agency, and any individuals or groups recognized as parties shall have the right to conduct discovery (including depositions) against...

  13. 15 CFR 23.3 - Plan.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Plan. 23.3 Section 23.3 Commerce and... MISSING CHILDREN § 23.3 Plan. (a) The Department of Commerce will supplement and expand the national... biannual meetings of departmental representatives to discuss the current plan and recommendations for...

  14. 45 CFR 86.23 - Recruitment.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Recruitment. 86.23 Section 86.23 Public Welfare... in Admission and Recruitment Prohibited § 86.23 Recruitment. (a) Nondiscriminatory recruitment. A recipient to which this subpart applies shall not discriminate on the basis of sex in the recruitment and...

  15. 34 CFR 106.23 - Recruitment.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Recruitment. 106.23 Section 106.23 Education... Discrimination on the Basis of Sex in Admission and Recruitment Prohibited § 106.23 Recruitment. (a) Nondiscriminatory recruitment. A recipient to which this subpart applies shall not discriminate on the basis of sex...

  16. 14 CFR 23.1191 - Firewalls.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Firewalls. 23.1191 Section 23.1191... § 23.1191 Firewalls. (a) Each engine, auxiliary power unit, fuel burning heater, and other combustion equipment, must be isolated from the rest of the airplane by firewalls, shrouds, or equivalent means. (b...

  17. 32 CFR 1602.23 - State.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false State. 1602.23 Section 1602.23 National Defense Other Regulations Relating to National Defense SELECTIVE SERVICE SYSTEM DEFINITIONS § 1602.23 State. The word State includes, where applicable, the several States of the United States, the City of New York...

  18. 21 CFR 900.23 - Evaluation.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Evaluation. 900.23 Section 900.23 Food and Drugs... STANDARDS ACT MAMMOGRAPHY States as Certifiers § 900.23 Evaluation. FDA shall evaluate annually the performance of each certification agency. The evaluation shall include the use of performance indicators that...

  19. 33 CFR 86.23 - Construction.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Construction. 86.23 Section 86.23 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INLAND NAVIGATION RULES ANNEX III: TECHNICAL DETAILS OF SOUND SIGNAL APPLIANCES Bell or Gong § 86.23 Construction. Bells and gongs...

  20. 39 CFR 958.23 - Settlement.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Settlement. 958.23 Section 958.23 Postal Service..., CLEAN-UP COSTS AND DAMAGES FOR VIOLATION OF HAZARDOUS MATERIAL REGULATIONS § 958.23 Settlement. Either party may make offers of settlement or proposals of adjustment at any time. The Determining Official has...

  1. 30 CFR 725.23 - Reports.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Reports. 725.23 Section 725.23 Mineral... REGULATIONS REIMBURSEMENTS TO STATES § 725.23 Reports. (a) The agency shall, for each grant made under this part, submit semiannually to the Director or his authorized designee a Financial Status Report, SF 269...

  2. 19 CFR 356.23 - Hearing.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Hearing. 356.23 Section 356.23 Customs Duties... § 356.23 Hearing. (a) Scheduling of hearing. The administrative law judge will schedule the hearing at a... parties adequately to prepare for the hearing and the importance of expeditiously resolving the matter. (b...

  3. High-reflectance La/B-based multilayer mirror for 6.x  nm wavelength

    NARCIS (Netherlands)

    Kuznetsov, Dmitry; Yakshin, Andrey; Sturm, Jacobus Marinus; van de Kruijs, Robbert Wilhelmus Elisabeth; Louis, Eric; Bijkerk, Frederik

    2015-01-01

    We report a hybrid thin-film deposition procedure to significantly enhance the reflectivity of La/B-based multilayer structures. This is of relevance for applications of multilayer optics at 6.7-nm wavelength and beyond. Such multilayers showed a reflectance of 64.1% at 6.65 nm measured at

  4. High efficiency single frequency 355 nm all-solid-state UV laser

    International Nuclear Information System (INIS)

    Xie, Xiaobing; Wei, Daikang; Ma, Xiuhua; Li, Shiguang; Liu, Jiqiao; Zhu, Xiaolei; Chen, Weibiao

    2016-01-01

    A novel conductively cooled high energy single-frequency 355 nm all-solid-state UV laser is presented based on sum-frequency mixing technique. In this system, a pulsed seeder laser at 1064 nm wavelength, modulated by an AOM, is directly amplified by the cascaded multi-stage hybrid laser amplifiers, and two LBO crystals are used for the SHG and SFG, finally a maximum UV pulse energy of 226 mJ at 355 nm wavelength is achieved with frequency-tripled conversion efficiency as high as 55%, the pulse width is around 12.2 ns at the repetition frequency of 30 Hz. The beam quality factor M 2 of the output UV laser is measured to be 2.54 and 2.98 respectively in two orthogonal directions. (paper)

  5. 14 CFR 23.755 - Hulls.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Hulls. 23.755 Section 23.755 Aeronautics... Hulls § 23.755 Hulls. (a) The hull of a hull seaplane or amphibian of 1,500 pounds or more maximum weight must have watertight compartments designed and arranged so that the hull auxiliary floats, and...

  6. 28 CFR 551.23 - Abortion.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Abortion. 551.23 Section 551.23 Judicial..., Pregnancy, Child Placement, and Abortion § 551.23 Abortion. (a) The inmate has the responsibility to decide either to have an abortion or to bear the child. (b) The Warden shall offer to provide each pregnant...

  7. Novel treatment of Hori's nevus: A combination of fractional nonablative 2,940-nm Er:YAG and low-fluence 1,064-nm Q-switched Nd:YAG laser.

    Science.gov (United States)

    Tian, Brian Wei Cheng Anthony

    2015-01-01

    To demonstrate a combination laser therapy to treat Hori's nevus. A prospective study. A Singapore-based clinic. Five female patients, aged 30-46 years, with bilateral malar Hori's nevus. Photographs were taken before treatment and 1 month after laser treatment was completed. These were graded by three independent physicians. The patients were also asked to grade their treatment response subjectively. They were followed up for a total of 3 months after laser treatment to monitor recurrence. The fractional nonablative 2,940-nm Er:YAG laser with a fluence of 0.7 J/cm(2), spot size 12 mm, and frequency 15 Hz was used to perform a full-face single-pass treatment. Subsequently, a second pass and third pass over Hori's nevi were done bilaterally till the clinical endpoint of skin whitening. The 1,064-nm Q-switched (QS) Nd:YAG at a fluence of 2.0 J/cm(2), frequency 2 Hz, and 4-mm spot size was used to deliver multiple passes over Hori's nevus till erythema with mild petechiae appeared. We repeated the treatment once a week for 3 more consecutive weeks. All five patients had above 80% improvement in their pigmentation and two (skin type III) achieved complete 100% clearance. Based on the patients' subjective assessments, all five of them expressed satisfaction and felt that their pigmentation had improved. There were no complications noted. The fractional nonablative 2940 nm Er:YAG laser and Q-switched 1064nm laser Nd:YAG combination is an effective and safe treatment for Hori's nevus.

  8. Optimum source/drain overlap design for 16 nm high-k/metal gate MOSFETs

    International Nuclear Information System (INIS)

    Jang, Junyong; Lim, Towoo; Kim, Youngmin

    2009-01-01

    We explore a source/drain (S/D) design for a 16 nm MOSFET utilizing a replacement process for a high-k gate dielectric and metal gate electrode integration. Using TCAD simulation, a trade-off study between series resistance and overlap capacitance is carried out for a high-k dielectric surrounding gate structure, which results from the replacement process. An optimum S/D overlap to gate for the high-k surrounding gate structure is found to be different from the conventional gate structure, i.e. 0∼1 nm underlap is preferred for the surround high-k gate structure while 1∼2 nm overlap for the conventional gate one

  9. 39 CFR 2.3 - Offices.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Offices. 2.3 Section 2.3 Postal Service UNITED STATES POSTAL SERVICE THE BOARD OF GOVERNORS OF THE U.S. POSTAL SERVICE GENERAL AND TECHNICAL PROVISIONS (ARTICLE II) § 2.3 Offices. The principal office of the Postal Service is located in Washington, DC, with...

  10. 21 CFR 17.23 - Discovery.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Discovery. 17.23 Section 17.23 Food and Drugs FOOD... HEARINGS § 17.23 Discovery. (a) No later than 60 days prior to the hearing, unless otherwise ordered by the..., depositions, and any forms of discovery, other than those permitted under paragraphs (a) and (e) of this...

  11. Integrated Active and Passive Polymer Optical Components with nm to mm Features

    DEFF Research Database (Denmark)

    Christiansen, Mads Brøkner; Schøler, Mikkel; Kristensen, Anders

    2007-01-01

    We present wafer-scale fabrication of integrated active and passive polymer optics with nm to mm features. First order DFB lasers, defined in dye doped SU-8 resist are integrated with SU-8 waveguides.......We present wafer-scale fabrication of integrated active and passive polymer optics with nm to mm features. First order DFB lasers, defined in dye doped SU-8 resist are integrated with SU-8 waveguides....

  12. REBL: design progress toward 16 nm half-pitch maskless projection electron beam lithography

    Science.gov (United States)

    McCord, Mark A.; Petric, Paul; Ummethala, Upendra; Carroll, Allen; Kojima, Shinichi; Grella, Luca; Shriyan, Sameet; Rettner, Charles T.; Bevis, Chris F.

    2012-03-01

    REBL (Reflective Electron Beam Lithography) is a novel concept for high speed maskless projection electron beam lithography. Originally targeting 45 nm HP (half pitch) under a DARPA funded contract, we are now working on optimizing the optics and architecture for the commercial silicon integrated circuit fabrication market at the equivalent of 16 nm HP. The shift to smaller features requires innovation in most major subsystems of the tool, including optics, stage, and metrology. We also require better simulation and understanding of the exposure process. In order to meet blur requirements for 16 nm lithography, we are both shrinking the pixel size and reducing the beam current. Throughput will be maintained by increasing the number of columns as well as other design optimizations. In consequence, the maximum stage speed required to meet wafer throughput targets at 16 nm will be much less than originally planned for at 45 nm. As a result, we are changing the stage architecture from a rotary design to a linear design that can still meet the throughput requirements but with more conventional technology that entails less technical risk. The linear concept also allows for simplifications in the datapath, primarily from being able to reuse pattern data across dies and columns. Finally, we are now able to demonstrate working dynamic pattern generator (DPG) chips, CMOS chips with microfabricated lenslets on top to prevent crosstalk between pixels.

  13. Ultralow-Power Electronic Trapping of Nanoparticles with Sub-10 nm Gold Nanogap Electrodes.

    Science.gov (United States)

    Barik, Avijit; Chen, Xiaoshu; Oh, Sang-Hyun

    2016-10-12

    We demonstrate nanogap electrodes for rapid, parallel, and ultralow-power trapping of nanoparticles. Our device pushes the limit of dielectrophoresis by shrinking the separation between gold electrodes to sub-10 nm, thereby creating strong trapping forces at biases as low as the 100 mV ranges. Using high-throughput atomic layer lithography, we manufacture sub-10 nm gaps between 0.8 mm long gold electrodes and pattern them into individually addressable parallel electronic traps. Unlike pointlike junctions made by electron-beam lithography or larger micron-gap electrodes that are used for conventional dielectrophoresis, our sub-10 nm gold nanogap electrodes provide strong trapping forces over a mm-scale trapping zone. Importantly, our technology solves the key challenges associated with traditional dielectrophoresis experiments, such as high voltages that cause heat generation, bubble formation, and unwanted electrochemical reactions. The strongly enhanced fields around the nanogap induce particle-transport speed exceeding 10 μm/s and enable the trapping of 30 nm polystyrene nanoparticles using an ultralow bias of 200 mV. We also demonstrate rapid electronic trapping of quantum dots and nanodiamond particles on arrays of parallel traps. Our sub-10 nm gold nanogap electrodes can be combined with plasmonic sensors or nanophotonic circuitry, and their low-power electronic operation can potentially enable high-density integration on a chip as well as portable biosensing.

  14. Magnetic rotational hysteresis study on spherical 85-160 nm Fe3O4 particles

    Science.gov (United States)

    Schmidbauer, E.

    1988-05-01

    Rotational hysteresis losses Wr were determined as a function of magnetic field H for dispensed spherical Fe3O4 particles of mean grain sizes 85 nm, 127 nm and 162 nm between 78 K and 294 K. The observed Wr-H curves are compared with theoretical curves for single domain particles. The analysed particles reveal centers of high magnetic anisotropy. Such centers can be of importance during the generation of a thermoremanent magnetization, as they may be the origin of enhanced magnetic stability.

  15. 78 FR 73581 - New Mexico Disaster Number NM-00035

    Science.gov (United States)

    2013-12-06

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 13809 and 13810] New Mexico Disaster Number NM... Mexico (FEMA-4152-DR), dated 10/29/2013. Incident: Severe Storms, Flooding, and Mudslides. Incident... 20416. SUPPLEMENTARY INFORMATION: The notice of the President's major disaster declaration for Private...

  16. Fabrication and stability of fiber bragg gratings for WDM applications using a 266 nm cw-laser

    DEFF Research Database (Denmark)

    Deyerl, Hans-Jürgen; Sørensen, Henrik Rokkjær; Jensen, Jesper Bo Damm

    2003-01-01

    Diode pumped continuous wave all solid state UV-lasers operating at 266 nm offer an interesting alternative to frequency doubled argon ion lasers. We compare photosensitivity, UV-writing of Bragg gratings and thermal decay at 244, 257 and 266 nm.......Diode pumped continuous wave all solid state UV-lasers operating at 266 nm offer an interesting alternative to frequency doubled argon ion lasers. We compare photosensitivity, UV-writing of Bragg gratings and thermal decay at 244, 257 and 266 nm....

  17. Absolute cross sections for emission of 284.7-nm (Hg II) and 479.7-nm (Hg III) radiation in electron--mercury-ion collisions

    International Nuclear Information System (INIS)

    Phaneuf, R.A.; Taylor, P.O.; Dunn, G.H.

    1976-01-01

    Crossed beams of electrons and Hg + ions have been used to measure absolute cross sections for emission of 284.7-nm radiation, resulting from excitation of a predominantly ground-state Hg + target to the 7s 2 S 1 / 2 state. Values range from 3 x 10 -17 cm 2 near threshold, where the cross section is strongly peaked, to 1.3 x 10 -18 cm 2 at 280 eV. Also reported are some measurements of emission of 479.7-nm (Hg III) radiation, resulting from electron impact on both Hg + and Hg ++ targets. Cross sections range from approximately 5 x 10 -19 to 5 x 10 -20 cm 2 , and in the case of electron-Hg ++ collisions, are more than an order of magnitude smaller than predicted by an available semiclassical binary-encounter calculation

  18. Formation of nickel germanides from Ni layers with thickness below 10 nm

    Energy Technology Data Exchange (ETDEWEB)

    Jablonka, Lukas; Kubart, Tomas; Primetzhofer, Daniel; Abedin, Ahmad; Hellström, Per-Erik; Östling, Mikael; Jordan-Sweet, Jean; Lavoie, Christian; Zhang, Shi-Li; Zhang, Zhen

    2017-03-01

    The authors have studied the reaction between a Ge (100) substrate and thin layers of Ni ranging from 2 to 10 nm in thickness. The formation of metal-rich Ni5Ge3Ni5Ge3 was found to precede that of the monogermanide NiGe by means of real-time in situ x-ray diffraction during ramp-annealing and ex situ x-ray pole figure analyses for phase identification. The observed sequential growth of Ni5Ge3Ni5Ge3 and NiGe with such thin Ni layers is different from the previously reported simultaneous growth with thicker Ni layers. The phase transformation from Ni5Ge3Ni5Ge3 to NiGe was found to be nucleation-controlled for Ni thicknesses <5 nm<5 nm, which is well supported by thermodynamic considerations. Specifically, the temperature for the NiGe formation increased with decreasing Ni (rather Ni5Ge3Ni5Ge3) thickness below 5 nm. In combination with sheet resistance measurement and microscopic surface inspection of samples annealed with a standard rapid thermal processing, the temperature range for achieving morphologically stable NiGe layers was identified for this standard annealing process. As expected, it was found to be strongly dependent on the initial Ni thickness

  19. Advances in 193 nm excimer lasers for mass spectrometry applications

    Science.gov (United States)

    Delmdahl, Ralph; Esser, Hans-Gerd; Bonati, Guido

    2016-03-01

    Ongoing progress in mass analysis applications such as laser ablation inductively coupled mass spectrometry of solid samples and ultraviolet photoionization mediated sequencing of peptides and proteins is to a large extent driven by ultrashort wavelength excimer lasers at 193 nm. This paper will introduce the latest improvements achieved in the development of compact high repetition rate excimer lasers and elaborate on the impact on mass spectrometry instrumentation. Various performance and lifetime measurements obtained in a long-term endurance test over the course of 18 months will be shown and discussed in view of the laser source requirements of different mass spectrometry tasks. These sampling type applications are served by excimer lasers delivering pulsed 193 nm output of several mJ as well as fast repetition rates which are already approaching one Kilohertz. In order to open up the pathway from the laboratory to broader market industrial use, sufficient component lifetimes and long-term stable performance behavior have to be ensured. The obtained long-term results which will be presented are based on diverse 193 nm excimer laser tube improvements aiming at e.g. optimizing the gas flow dynamics and have extended the operational life the laser tube for the first time over several billion pulses even under high duty-cycle conditions.

  20. Design and analysis of 30 nm T-gate InAlN/GaN HEMT with AlGaN back-barrier for high power microwave applications

    Science.gov (United States)

    Murugapandiyan, P.; Ravimaran, S.; William, J.; Meenakshi Sundaram, K.

    2017-11-01

    In this article, we present the DC and microwave characteristics of a novel 30 nm T-gate InAlN/AlN/GaN HEMT with AlGaN back-barrier. The device structure is simulated by using Synopsys Sentaurus TCAD Drift-Diffusion transport model at room temperature. The device features are heavily doped (n++ GaN) source/drain regions with Si3N4 passivated device surface for reducing the contact resistances and gate capacitances of the device, which uplift the microwave characteristics of the HEMTs. 30 nm gate length D-mode (E-mode) HEMT exhibited a peak drain current density Idmax of 2.3 (2.42) A/mm, transconductance gm of 1.24(1.65) S/mm, current gain cut-off frequency ft of 262 (246) GHz, power gain cut-off frequency fmax of 246(290) GHz and the three terminal off-state breakdown voltage VBR of 40(38) V. The preeminent microwave characteristics with the higher breakdown voltage of the proposed GaN-based HEMT are the expected to be the most optimistic applicant for future high power millimeter wave applications.

  1. Simultaneous response of NmF2 and GPS-TEC to storm events at Ilorin

    Science.gov (United States)

    Joshua, B. W.; Adeniyi, J. O.; Oladipo, O. A.; Doherty, P. H.; Adimula, I. A.; Olawepo, A. O.; Adebiyi, S. J.

    2018-06-01

    A comparative study of both TEC and NmF2 variations during quiet and disturbed conditions has been investigated using simultaneous measurements from dual frequency Global Positioning System (GPS) receiver and a DPS-4 Digisonde co-located at Ilorin (Geog. Lat. 8.50°N, Long. 4.50°E, dip. - 7.9°). The results of the quiet time variations of the two parameters show some similarities as well as differences in their structures. The values of both parameters generally increase during the sunrise period attaining a peak around the noon and then decaying towards the night time. The onset time of the sunrise growth is observed to be earlier in TEC than in NmF2. The rate of decay of TEC was observed to be faster than that of the NmF2 in most cases. Also, the noon 'bite-outs', leading to the formation of pre-noon and post-noon peaks, are prominent in the NmF2 structure and was hardly noticed in TEC. Results of the variations of both TEC and NmF2 during the 5 April, 10 May and 3 August 2010 geomagnetic storm events showed a simultaneous deviations of both parameters from the quiet time behavior. The magnitude of the deviations is however most pronounced in NmF2 structure than in TEC. We also found that the enhancement observed in the two parameters during the storm events generally corresponds to decrease in hmF2.

  2. Mechanisms involved in HBr and Ar cure plasma treatments applied to 193 nm photoresists

    International Nuclear Information System (INIS)

    Pargon, E.; Menguelti, K.; Martin, M.; Bazin, A.; Joubert, O.; Chaix-Pluchery, O.; Sourd, C.; Derrough, S.; Lill, T.

    2009-01-01

    In this article, we have performed detailed investigations of the 193 nm photoresist transformations after exposure to the so-called HBr and Ar plasma cure treatments using various characterization techniques (x-ray photoelectron spectroscopy, Fourier transformed infrared, Raman analyses, and ellipsometry). By using windows with different cutoff wavelengths patched on the photoresist film, the role of the plasma vacuum ultraviolet (VUV) light on the resist modifications is clearly outlined and distinguished from the role of radicals and ions from the plasma. The analyses reveal that both plasma cure treatments induce severe surface and bulk chemical modifications of the resist films. The synergistic effects of low energetic ion bombardment and VUV plasma light lead to surface graphitization or cross-linking (on the order of 10 nm), while the plasma VUV light (110-210 nm) is clearly identified as being responsible for ester and lactone group removal from the resist bulk. As the resist modification depth depends strongly on the wavelength penetration into the material, it is found that HBr plasma cure that emits near 160-170 nm can chemically modify the photoresist through its entire thickness (240 nm), while the impact of Ar plasmas emitting near 100 nm is more limited. In the case of HBr cure treatment, Raman and ellipsometry analyses reveal the formation of sp 2 carbon atoms in the resist bulk, certainly thanks to hydrogen diffusion through the resist film assisted by the VUV plasma light.

  3. Spectroscopy of Pluto, 380-930 Nm at Six Longitudes

    Science.gov (United States)

    Cruikshank, D. P.; Pinilla-Alonso, N.; Lorenzi, V.; Grundy, William; Licandro, J.; Binzel, R. P.

    2014-01-01

    We have obtained spectra of the Pluto-Charon pair (unresolved) in the wavelength range 380-930 nm with resolution approx..450 at six roughly equally spaced longitudes. The data were taken in May and June, 2014, with the 4.2-m Isaac Newton Telescope at Roque de Los Muchachos Observatory in the Canary Islands, using the ACAM (auxiliary-port camera) in spectrometer mode, and using two solar analog stars. The new spectra clearly show absorption bands of solid CH4 at 620, 728, and 850-910 nm, which were known from earlier work. The 620-nm CH4 band is intrinsically very weak, and its appearance indicates a long optical path-length through the ice. This is especially true if it arises from CH4 dissolved in N2 ice. Earlier work (Owen et al. Science 261, 745, 1993) on the near-infrared spectrum of Pluto (1-2.5 microns) has shown that the CH4 bands are shifted to shorter wavelengths because the CH4 occurs as a solute in beta-phase crystalline N2. The optical path-length through the N2 crystals must be on the order of several cm to produce the N2 band observed at 2.15 microns. The new spectra exhibit a pronounced red slope across the entire wavelength range; the slope is variable with longitude, and differs in a small but significant way from that measured at comparable longitudes by Grundy & Fink (Icarus 124, 329, 1996) in their 15-year study of Pluto's spectrum (500-1000 nm). The new spectra will provide an independent means for calibrating the color filter bands on the Multispectral Visible Imaging Camera (MVIC) (Reuter et al. Space Sci. Rev. 140, 129, 2008) on the New Horizons spacecraft, which will encounter the Pluto-Charon system in mid-2015. They will also form the basis of modeling the spectrum of Pluto at different longitudes to help establish the nature of the non-ice component(s) of Pluto's surface. It is presumed that the non-ice component is the source of the yellow-red coloration of Pluto, which is known to be variable across the surface.

  4. Continuous-wave, single-frequency 229  nm laser source for laser cooling of cadmium atoms.

    Science.gov (United States)

    Kaneda, Yushi; Yarborough, J M; Merzlyak, Yevgeny; Yamaguchi, Atsushi; Hayashida, Keitaro; Ohmae, Noriaki; Katori, Hidetoshi

    2016-02-15

    Continuous-wave output at 229 nm for the application of laser cooling of Cd atoms was generated by the fourth harmonic using two successive second-harmonic generation stages. Employing a single-frequency optically pumped semiconductor laser as a fundamental source, 0.56 W of output at 229 nm was observed with a 10-mm long, Brewster-cut BBO crystal in an external cavity with 1.62 W of 458 nm input. Conversion efficiency from 458 nm to 229 nm was more than 34%. By applying a tapered amplifier (TA) as a fundamental source, we demonstrated magneto-optical trapping of all stable Cd isotopes including isotopes Cd111 and Cd113, which are applicable to optical lattice clocks.

  5. CORRECTION OF THE TEMPERATURE EFFECT IN 1020 NM BAND OF SUN-SKY RADIOMETER

    Directory of Open Access Journals (Sweden)

    K. Li

    2018-04-01

    Full Text Available Aerosol is an important part of the earth-atmosphere system. It can directly and indirectly influence solar radiation and then affect the energy balance of earth-atmosphere system. AERONET, as the largest ground-based observation network, provides multi-parameters of aerosol from more than 600 hundred sites using sun-sky radiometer, which contains 9 channels from 340 nm to 1640 nm. Among which, 1020 nm channel is greatly influenced by the temperature. In this paper, a new correction method of 1020 nm band is introduced. The new method transfers the temperature correction coefficient of the master radiometer to the comparative one. The filed calibration experiment shown that the temperature correction coefficient obtained by this method is close to the result from the temperature controlled chamber, and the difference is about 2.1 %. This new method is easy-to-use, and its accuracy is comparable to the standard one. It is more applicable for large-scale instrument calibration. In principle, this method is applicable to all bands of the sun-sky radiometer.

  6. Correction of the Temperature Effect in 1020 NM Band of Sun-Sky Radiometer

    Science.gov (United States)

    Li, K.; Li, Z.; Li, D.; Xie, Y.; Xu, H.

    2018-04-01

    Aerosol is an important part of the earth-atmosphere system. It can directly and indirectly influence solar radiation and then affect the energy balance of earth-atmosphere system. AERONET, as the largest ground-based observation network, provides multi-parameters of aerosol from more than 600 hundred sites using sun-sky radiometer, which contains 9 channels from 340 nm to 1640 nm. Among which, 1020 nm channel is greatly influenced by the temperature. In this paper, a new correction method of 1020 nm band is introduced. The new method transfers the temperature correction coefficient of the master radiometer to the comparative one. The filed calibration experiment shown that the temperature correction coefficient obtained by this method is close to the result from the temperature controlled chamber, and the difference is about 2.1 %. This new method is easy-to-use, and its accuracy is comparable to the standard one. It is more applicable for large-scale instrument calibration. In principle, this method is applicable to all bands of the sun-sky radiometer.

  7. Blue laser diode (450 nm) systems for welding copper

    Science.gov (United States)

    Silva Sa, M.; Finuf, M.; Fritz, R.; Tucker, J.; Pelaprat, J.-M.; Zediker, M. S.

    2018-02-01

    This paper will discuss the development of high power blue laser systems for industrial applications. The key development enabling high power blue laser systems is the emergence of high power, high brightness laser diodes at 450 nm. These devices have a high individual brightness rivaling their IR counterparts and they have the potential to exceed their performance and price barriers. They also have a very high To resulting in a 0.04 nm/°C wavelength shift. They have a very stable lateral far-field profile which can be combined with other diodes to achieve a superior brightness. This paper will report on the characteristics of the blue laser diodes, their integration into a modular laser system suitable for scaling the output power to the 1 kW level and beyond. Test results will be presented for welding of copper with power levels ranging from 150 Watts to 600 Watts

  8. Doppler-free two-photon spectroscopy of Yb atoms and efficient generation of a cascade of two photons at 611.3 nm and 555.8 nm

    International Nuclear Information System (INIS)

    Song, Minsoo; Yoon, Duseong; Yoon, Taihyun

    2011-01-01

    We performed high-resolution Doppler-free two-photon spectroscopy of Yb atoms in an effusive atomic beam and generated a cascade of two photons at 611.3 nm (idler) and 555.8 nm (signal) with a narrow bandwidth of 37 MHz. Efficient population transfer from the ground state (6s 2 1 S 0 ) to the upper state (6s7s 1 S 0 ), where direct transition at 291.1 nm is dipole forbidden, was achieved through a resonant two-photon excitation enhanced by the electromagnetically-induced transparency mediated by the intermediate state (6s6p 1 P 1 ). From the upper state, a cascade of two photons in sequence was emitted via the spin triplet state (6s 2 3 P 1 ). Numerical calculations of the density matrix equations taking into account the residual Doppler effect and strong driving fields explain quantitatively the experimental results for the dependences of the idler and the signal beam intensities on the various parameters of the driving fields. We report on the generation of a cascade of two photons with fluxes at the level of a few times 10 6 photons/s detected at a solid angle of 0.01 sr.

  9. Doppler-free two-photon spectroscopy of Yb atoms and efficient generation of a cascade of two photons at 611.3 nm and 555.8 nm

    Energy Technology Data Exchange (ETDEWEB)

    Song, Minsoo; Yoon, Duseong; Yoon, Taihyun [Korea University, Seoul (Korea, Republic of)

    2011-10-15

    We performed high-resolution Doppler-free two-photon spectroscopy of Yb atoms in an effusive atomic beam and generated a cascade of two photons at 611.3 nm (idler) and 555.8 nm (signal) with a narrow bandwidth of 37 MHz. Efficient population transfer from the ground state (6s{sup 2} {sup 1}S{sub 0}) to the upper state (6s7s {sup 1}S{sub 0}), where direct transition at 291.1 nm is dipole forbidden, was achieved through a resonant two-photon excitation enhanced by the electromagnetically-induced transparency mediated by the intermediate state (6s6p {sup 1}P{sub 1}). From the upper state, a cascade of two photons in sequence was emitted via the spin triplet state (6s{sup 2} {sup 3}P{sub 1}). Numerical calculations of the density matrix equations taking into account the residual Doppler effect and strong driving fields explain quantitatively the experimental results for the dependences of the idler and the signal beam intensities on the various parameters of the driving fields. We report on the generation of a cascade of two photons with fluxes at the level of a few times 10{sup 6} photons/s detected at a solid angle of 0.01 sr.

  10. Present status and future prospect of x-ray microscopes. Is it possible to realize x-ray 1 nm imaging?

    International Nuclear Information System (INIS)

    Aoki, Sadao

    2010-01-01

    High resolution X-ray imaging has been developed by using various optical elements and optical systems. In the soft X-ray region (∼3 nm) about 20 nm spatial resolution has been obtained, while in the hard X-ray (∼0.1 nm) about 50 nm. In the research frontier the spatial resolution better than 10 nm has been reported. The possibility to approach 1 nm spatial resolution is presented. (author)

  11. A 1470-nm laser combined with foam sclerotherapy in day surgery: a better choice for lower limb varicose veins.

    Science.gov (United States)

    Zhang, Xing; Wang, Xin; Gao, Cheng; Qin, Jinbao; Zhao, Haiguang; Li, Weimin; Lu, Xinwu

    2018-04-23

    Day surgery is being more and more adopted by clinicians. Higher wavelength lasers give patients better experience than lower wavelength lasers, which makes it more suitable for day surgery. This study compares the short- and mid-term efficacy, postoperative morbidity, and patient satisfaction of "1470-nm endovenous laser ablation (EVLA) combining foam sclerotherapy in day surgery" with "810-nm EVLA with high ligation combining foam sclerotherapy in hospital surgery" on great saphenous vein (GSV) insufficiency postoperatively. A single-institution historical cohort study of 194 patients was performed in Shanghai Ninth People's Hospital, China. Ninety-seven patients received 1470-nm EVLA combining foam sclerotherapy in day surgery ("1470-nm group"), and 97 patients received 810-nm EVLA with high ligation combining foam sclerotherapy in hospital surgery recommended by guidelines ("810-nm group"). No significant difference was found between the 1470-nm group and the 810-nm group in terms of GSV occlusion rate (both 100%), complication rate, and recurrence rate (8.2 vs. 11.3%) during the period of 1-12 months after surgery. Serious complications in the 1470-nm group and 810-nm group were 0 and 1.0%. Minor complications in the 1470-nm group and 810-nm group were ecchymosis at 20.6 and 18.6%, edema at 69.1 and 63.9%, and paresthesia around ankle at 0 and 3.1%, respectively. Advantage of the 1470-nm group over the 810-nm group was statistically significant considering the patient perioperative comfort and economic cost. Treatment of 1470-nm EVLA combining foam sclerotherapy in day surgery has similar efficacy as the 810-nm EVLA with high ligation combining foam sclerotherapy in hospital surgery in GSV insufficiency and is more comfortable with less incision, hospitalization procedure, and medical costs. It may be a new option for patients who are afraid or unable to be hospitalized.

  12. Complete resolution of minocycline pigmentation following a single treatment with non-ablative 1550-nm fractional resurfacing in combination with the 755-nm Q-switched alexandrite laser.

    Science.gov (United States)

    Vangipuram, Ramya K; DeLozier, Whitney L; Geddes, Elizabeth; Friedman, Paul M

    2016-03-01

    Pigmentation secondary to minocycline ingestion is an uncommon adverse event affecting 3.7-14.8% of treated individuals for which few effective therapies are available. Three patterns of minocycline pigmentation have a characteristic clinical and histological appearance. The pigment composition in each variety is different and occurs at varying skin depths. Accordingly, a tailored approach according to the type of minocycline pigmentation is crucial for treatment success. The purpose of this intervention was to evaluate the efficacy of non-ablative fractional photothermolysis in combination with the Q-switched alexandrite laser for the treatment of type I minocycline pigmentation on the face. A patient with type I minocycline pigmentation was treated with non-ablative 1550-nm fractional photothermolysis followed immediately by 755-nm Q-switched alexandrite laser and then observed clinically to determine the outcome of this modality. The patient was seen in clinic 1 month later following her single treatment session and 100% clearance of all blue facial pigment was observed. Non-ablative fractional photothermolysis in combination with the 755-nm Q-switched alexandrite laser should be considered for treatment of type I minocycline pigmentation. © 2015 Wiley Periodicals, Inc.

  13. Physiological Actions of Fibroblast Growth Factor-23

    Directory of Open Access Journals (Sweden)

    Reinhold G. Erben

    2018-05-01

    Full Text Available Fibroblast growth factor-23 (FGF23 is a bone-derived hormone suppressing phosphate reabsorption and vitamin D hormone synthesis in the kidney. At physiological concentrations of the hormone, the endocrine actions of FGF23 in the kidney are αKlotho-dependent, because high-affinity binding of FGF23 to FGF receptors requires the presence of the co-receptor αKlotho on target cells. It is well established that excessive concentrations of intact FGF23 in the blood lead to phosphate wasting in patients with normal kidney function. Based on the importance of diseases associated with gain of FGF23 function such as phosphate-wasting diseases and chronic kidney disease, a large body of literature has focused on the pathophysiological consequences of FGF23 excess. Less emphasis has been put on the role of FGF23 in normal physiology. Nevertheless, during recent years, lessons we have learned from loss-of-function models have shown that besides the paramount physiological roles of FGF23 in the control of 1α-hydroxylase expression and of apical membrane expression of sodium-phosphate co-transporters in proximal renal tubules, FGF23 also is an important stimulator of calcium and sodium reabsorption in distal renal tubules. In addition, there is an emerging role of FGF23 as an auto-/paracrine regulator of alkaline phosphatase expression and mineralization in bone. In contrast to the renal actions of FGF23, the FGF23-mediated suppression of alkaline phosphatase in bone is αKlotho-independent. Moreover, FGF23 may be a physiological suppressor of differentiation of hematopoietic stem cells into the erythroid lineage in the bone microenvironment. At present, there is little evidence for a physiological role of FGF23 in organs other than kidney and bone. The purpose of this mini-review is to highlight the current knowledge about the complex physiological functions of FGF23.

  14. Two-photon-excited fluorescence spectroscopy of atomic fluorine at 170 nm

    Science.gov (United States)

    Herring, G. C.; Dyer, Mark J.; Jusinski, Leonard E.; Bischel, William K.

    1988-01-01

    Two-photon-excited fluorescence spectroscopy of atomic fluorine is reported. A doubled dye laser at 286-nm is Raman shifted in H2 to 170 nm (sixth anti-Stokes order) to excite ground-state 2P(0)J fluorine atoms to the 2D(0)J level. The fluorine atoms are detected by one of two methods: observing the fluorescence decay to the 2PJ level or observing F(+) production through the absorption of an additional photon by the excited atoms. Relative two-photon absorption cross sections to and the radiative lifetimes of the 2D(0)J states are measured.

  15. Laser–fibre vibrometry at 1550 nm

    International Nuclear Information System (INIS)

    Waz, A T; Kaczmarek, P R; Abramski, K M

    2009-01-01

    This paper presents new solutions for laser vibrometry, which are based on fibre vibrometry in the third telecommunication window. The scattered laser beam from a vibrating object is guided by a fibre collimator and coherently detected through heterodyning it with an acousto-optical frequency-shifted reference beam. The concept of measuring vibration parameters from many points of the vibrating object has been inspired by wavelength division multiplexing (WDM) in fibre telecommunications. The N-independent WDM separated 15XX nm fibre-coupled laser diodes (used for optical fibre telecommunications) form a system of sources for multipoint vibration measurement according to the rule 'one wavelength–one point'

  16. 1018 nm Yb-doped high-power fiber laser pumped by broadband pump sources around 915 nm with output power above 100 W

    DEFF Research Database (Denmark)

    Midilli, Yakup; Efunbajo, Oyewole Benjamin; Şimşek, Bartu

    2017-01-01

    laser were also addressed in this study. Finally, we have tested this system for high power experimentation and obtained 67% maximum optical-to-optical efficiency at an approximately 110 W output power level. To the best of our knowledge, this is the first 1018 nm ytterbium-doped all-fiber laser pumped...

  17. Spectroscopy and decay kinetics of Pr3+-doped chloride crystals for 1300-nm optical amplifiers

    International Nuclear Information System (INIS)

    Page, R.H.; Schaffers, K.I.; Wilke, G.D.

    1995-01-01

    Several Pr 3+ -doped chloride crystals have been tested spectroscopically for suitability as 1300-nm optical amplifiers operating on the 1 G 4 - 3 H 5 transition. 1 G 4 lifetimes are much longer than in fluoride hosts, ranging up to 1300 μsec and suggesting a near-unity luminescence quantum yield. Emission spectra are typically broad (FWHM ∼ 70 nm) and include the 1310-nm zero-dispersion wavelength of standard telecommunications fiber

  18. Low-spin states of 23Na

    International Nuclear Information System (INIS)

    Bakkum, E.L.

    1987-01-01

    A study of 23 Na via the 22 Ne(p,γ) 23 Na and 23 Na(γ,γ) 23 Na reactions is presented. Only a limited number of resonances has been studied, selected on the basis of strong excitation of the lowest levels of which the spin was unknown. As a result the spins are now known of all levels of 23 Na with excitation energies up to 7 MeV, except for a few high-spin states which are too weakly excited in the decay of the known 22 Ne(p,γ) resonances. The mean lifetimes of the 23 Na levels at 4.43 and 7.89 MeV were found to be 350±70 and 220±17 attoseconds (1 attosecond = 10 -18 seconds) respectively. 97 refs.; 22 figs.; 12 tabs

  19. Synthesis and properties of 1,3-dioxo-1H-inden-2(3H)-ylidene fragment and (3-(dicyanomethylene)-5,5-dimethylcyclohex-1-enyl)vinyl fragment containing derivatives of azobenzene for holographic recording materials

    Science.gov (United States)

    Zarins, Elmars; Kokars, Valdis; Ozols, Andris; Augustovs, Peteris

    2011-06-01

    New glassy 1,3-dioxo-1H-inden-2(3H)-ylidene fragment und (3-(dicyanomethylene)-5,5-dimethylcyclohex-1-enyl)vinyl fragment containing push-pull type derivatives of azobenzene able to create thin layers have been synthesized. Thin films of synthesized glasses for holographic recording were prepared using spin coating technique from saturated chloroform solution. Holographic grating recording in films of 6a-b, 7 and 12 has been experimentally studied at 633 and 532 nm in both transmission and reflection modes with p-p recording beam polarizations. The film 12 was found to be the most efficient at both wavelengths in transmission mode exhibiting the maximum self-diffraction efficiency of 9.9% at 633 nm, and 15.3% at 532 nm. The film of 6a was the most efficient in reflection mode with the maximum selfdiffraction efficiency of about 3%.

  20. Nearly penalty-free, less than 4 ps supercontinuum Gbit/s pulse generation over 1535-1560 nm

    Science.gov (United States)

    Morioka, T.; Kawanishi, S.; Mori, K.; Saruwatari, M.

    1994-05-01

    Nearly penalty-free less than 4ps supercontinuum WDM pulses are generated at 6.3 Gbit/s over 1535-1560 nm for the first time using a 200 nm superbroadened supercontinuum in an optical fibre pumped by 1.7 W, 3.3 ps, 1542 nm short pulses from an Er(3+)-doped fibre ring laser.

  1. Tunable high-power narrow-spectrum external-cavity diode laser based on tapered amplifier at 668 nm

    DEFF Research Database (Denmark)

    Chi, Mingjun; Erbert, G.; Sumpf, B.

    2010-01-01

    A 668 nm tunable high-power narrow-spectrum diode laser system based on a tapered semiconductor optical amplifier in external cavity is demonstrated. The laser system is tunable from 659 to 675 nm. As high as 1.38 W output power is obtained at 668.35 nm. The emission spectral bandwidth is less than...

  2. Transcanalicular laser dacryocystorhinostomy using low energy 810 nm diode laser

    Directory of Open Access Journals (Sweden)

    Sanjiv K Gupta

    2012-01-01

    Conclusions: Transcanalicular Laser DCR can be safely performed using a low power 810 nm diode laser. The surgery is elegant, minimally invasive, allows fast rehabilitation, and has an excellent success rate.

  3. A New Method for the Synthesis of 2,3-Aziridino-2,3-dideoxyhexonamides and Their Conversion into 3-Amoni-2,3-dideoxyhexonic Acids

    DEFF Research Database (Denmark)

    Jørgensen, Christel Thea; Pedersen, Christian; Søtofte, Inger

    1998-01-01

    The new 2,3-Aziridino-2,3-dideoxyhexonamides 3 and 11 were prepared by a three-step procedure from commercially available D-glucono-1,5-lactone and D-gulono-1,4-lactone, respectively. The lactones were converted into methyl 3,4;5,6-di-O-isopropylidene-2-Omesyl esters 2 and 10, which upon treatmen...... with ammonia formed the title aziridino compounds. These were reductively cleaved by hydrazine to give 3-amino-2,3-dideoxyhexonic hydrazides 13 and 15, which were easily converted into corresponding lactone 14 and acid 16, respectively....

  4. Waste minimization/pollution prevention at R ampersand D facilities: Implementing the SNL/NM Process Waste Assessment Program

    International Nuclear Information System (INIS)

    Kjeldgaard, E.A.; Stermer, D.L.; Saloio, J.H. Jr.; Lorton, G.A.

    1993-01-01

    The Sandia National Laboratories, New Mexico (SNL/NM) Process Waste Assessment (PWA) program began formally on November 2, 1992. This program represents the first laboratory-wide attempt to explicitly identify and characterize SNL/NM's waste generating processes for waste minimization purposes. This paper describes the major elements of the SNL/NM PWA program, the underlying philosophy for designing a PWA program at a highly diverse laboratory setting such as SNL/NM, and the experiences and insights gained from five months of implementing this living program. Specifically, the SNL/NM PWA program consists of four major, interrelated phases: (1) Process Definition, (2) Process Characterization, (3) Waste Minimization Opportunity Assessment, and (4) Project Evaluation, Selection, Implementation, and Tracking. This phased approach was developed to Provide a flexible, yet appropriate, level of detail to the multitude of different ''processes'' at SNL/NM. Using a staff infrastructure of approximately 60 Waste Minimization Network Representatives (MinNet Reps) and consulting support, the SNL/NM PWA program has become the linchpin of even more progressive and proactive environmental, safety, and health (ES ampersand H) initiatives such as: (1) cradle-to-grove material/waste tracking, (2) centralized ES ampersand H reporting, and (3) detailed baselining and tracking for measuring multi-media waste reduction goals. Specific examples from the SNL/NM PWA program are provided, including the results from Process Definition, Process Characterization, and Waste Minimization Opportunity Assessments performed for a typical SNL/NM process

  5. Both interleukin-23A polymorphism and serum interlukin-23 expression are associated with Graves' disease risk.

    Science.gov (United States)

    Jia, Huiying; Tao, Feng; Liu, Changqin; Guo, Ting; Zhu, Wei; Wang, Shu; Cui, Bin; Ning, Guang

    2015-03-01

    Two independent Chinese cohorts were used to study the genetic association between the interleukin-23A (IL-23A) gene polymorphism (rs11171806) and susceptibility to Graves' disease (GD). The initial Shanghai cohort consisted of 712 unrelated patients with GD and 705 healthy control subjects, and the replication cohort from Xiamen Island included 433 patients with GD and 410 healthy control subjects. The serum concentration of IL-23 in GD patients was measured significantly higher than in health controls. Moreover in the subgroup analysis, higher concentrations of IL-23 were identified in patients of older age (⩾40 years) and female gender. We also performed an association study with the IL-23 gene polymorphism rs11171806 in both cohorts, in Shanghai cohorts, the frequencies of rs11171806 alleles were strongly different between Graves' disease patients (G 95.7% and A 4.3%) and healthy controls (G 97.7% and A 2.3%) (P=2.6×10(-3), OR=1.93 (95% CI: 1.25-2.97)), and in Xiamen cohorts, the proportion of individuals carrying the A allele of rs11171806 was the same significantly higher in Graves' disease patients than in controls [Graves' disease vs. control, 4.8% vs. 4.3%, OR=2.15 (95% CI: 1.23-3.79), P(allele)=6.3×10(-3)]. The distribution of rs11171806 genotype was also investigated in subgroups according to the age and gender. All of these findings suggested that IL-23 may play an important role in the development of GD, and the IL-23A gene is a genetic risk marker for GD in Han Chinese population. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Flat-topped emission centred at 1 250 nm from quantum dot superluminescent diodes

    Directory of Open Access Journals (Sweden)

    R.A. Hogg

    2010-01-01

    Full Text Available We present a method for tailoring a broadband and flat-topped emission spectrum in quantum dot superluminescent diodes based upon modification of the dots-in-compositionally-modulated-well (DCMWELL technique. We demonstrate flat-topped emission with 95 nm full width at half maximum (FWHM, centred at 1 250 nm, and with output power in excess of 8 mW.

  7. Continuous wave and AO Q-switch operation Tm,Ho:YAP laser pumped by a laser diode of 798 nm

    International Nuclear Information System (INIS)

    Li, L J; Yao, B Q; Song, C W; Wang, Y Z; Wang, Z G

    2009-01-01

    Continuous wave (CW) and acousto-optical (AO) Q-switch operation of Tm (5 at.%), Ho (0.3 at.%):YAP laser at 2.13 μm wavelength were reported in this paper. The Tm,Ho:YAP crystal was cooled by liquid nitrogen and double-end-pumped by a 14.2 W fiber-coupled laser diode at 798 nm. Different resonator lengths and output couplers for the pump power were tried. A maximum conversion efficiency of 31.3% and a maximum slope efficiency of 35.2% were acquired with CW output power of 4.45 W. Average power of 4.21 W was obtained at pulse repetition frequency (PRF) of 15 kHz, corresponding to an optical-to-optical conversion efficiency of 29.6% and a slope efficiency of 32.4%. The energy per pulse of 2.3 mJ in 64 ns was achieved at 1.5 kHz with the peak power of 35.8 kW

  8. The restoration in vivo of 2,3-diphosphoglycerate (2,3-DPG) in stored red cells, after transfusion. The levels of red cells 2,3-DPG.

    Science.gov (United States)

    Stan, Ana; Zsigmond, Eva

    2009-01-01

    Since the main reason for transfusing preserved red cells is to increase the oxygen carrying capacity of the recipient, the circulating preserved red cells should have at the time of transfusion normal oxygen uptake and normal oxyhemoglobin dissociation characteristics. We evaluated the effectiveness of transfused red cells, through periodical determination of erythrocyte components, during 72 hours after transfusions of large quantities (3,000 mL) of blood. Three patients with massive hemorrhages, two after amputation and one after nephrectomy were given each 3,000 mL preserved blood (in ACD, 10 days, at 4 degrees C). Red cell 2,3-DPG and serum inorganic phosphorus were determined prior to transfusion and after, periodically, for three days. Red cell 2,3-DPG was determined by Krimsky's method and inorganic phosphorus by Kuttner and Lichtenstein's method. The in vivo restoration of 2,3-DPG--of transfused red cells is shown as a percentage of recipient's final 2,3-DPG level, and was calculated in each of the three patients. The level of erythrocyte 2,3-DPG was greater than 60% of the final level within 24 hours, after the end of transfusion. The in vivo rates of restoration of 2,3-DPG in transfused red cells for periods of 0-6, 6-24, 24-48 and 48-72 hours are 0.251, 0.238, 0.133, 0.120 mM/L cells/hour. The therapeutic significance of the increased oxygen affinity of stored blood becomes very important in clinical conditions, when large volumes of red cells are urgently needed. After massive transfusions, the restoration of 2,3-DPG in red cells produces a decrease of serum inorganic phosphorus through its consumption. The stored blood with low values of erythrocyte 2,3-DPG can be used without hesitation when correcting a chronic anemia for instance, but in acute situation, when the organism needs restoration of the oxygen releasing capacity within minutes, the resynthesis is obviously insufficient. In such situations, fresh blood or blood with a near normal 2,3-DPG

  9. National Environmental Policy Act (NEPA) compliance at Sandia National Laboratories/New Mexico (SNL/NM)

    International Nuclear Information System (INIS)

    Wolff, T.A.

    1998-08-01

    This report on National Environmental Policy Act (NEPA) compliance at Sandia National Laboratories/New Mexico (SNL/NM) chronicles past and current compliance activities and includes a recommended strategy that can be implemented for continued improvement. This report provides a list of important references. Attachment 1 contains the table of contents for SAND95-1648, National Environmental Policy Act (NEPA) Compliance Guide Sandia National Laboratories (Hansen, 1995). Attachment 2 contains a list of published environmental assessments (EAs) and environmental impact statements (EISs) prepared by SNL/NM. Attachment 3 contains abstracts of NEPA compliance papers authored by SNL/NM and its contractors

  10. Broadband superluminescent diodes and semiconductor optical amplifiers for the spectral range 750 - 800 nm

    International Nuclear Information System (INIS)

    Il'chenko, S N; Kostin, Yu O; Kukushkin, I A; Ladugin, M A; Lapin, P I; Lobintsov, A A; Marmalyuk, Aleksandr A; Yakubovich, S D

    2011-01-01

    We have studied superluminescent diodes (SLDs) and semiconductor optical amplifiers (SOAs) based on an (Al x Ga 1-x )As/GaAs single quantum well structure with an Al content x ∼ 0.1 in a 10-nm-thick active layer. Depending on the length of the active channel, the single-mode fibre coupled cw output power of the SLDs is 1 to 30 mW at a spectral width of about 50 nm. The width of the optical gain band in the active channel exceeds 40 nm. Preliminary operating life tests have demonstrated that the devices are sufficiently reliable. (lasers)

  11. National Environmental Policy Act (NEPA) compliance at Sandia National Laboratories/New Mexico (SNL/NM)

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, T.A. [Sandia National Labs., Albuquerque, NM (United States). Community Involvement and Issues Management Dept.; Hansen, R.P. [Hansen Environmental Consultants, Englewood, CO (United States)

    1998-08-01

    This report on National Environmental Policy Act (NEPA) compliance at Sandia National Laboratories/New Mexico (SNL/NM) chronicles past and current compliance activities and includes a recommended strategy that can be implemented for continued improvement. This report provides a list of important references. Attachment 1 contains the table of contents for SAND95-1648, National Environmental Policy Act (NEPA) Compliance Guide Sandia National Laboratories (Hansen, 1995). Attachment 2 contains a list of published environmental assessments (EAs) and environmental impact statements (EISs) prepared by SNL/NM. Attachment 3 contains abstracts of NEPA compliance papers authored by SNL/NM and its contractors.

  12. Effects of photoprotection and reversible inactivation of the yeast Candida guilliermondii, induced by 313 nm light

    International Nuclear Information System (INIS)

    Frajkin, G.Ya.; Pospelov, M.E.; Rubin, L.B.

    1976-01-01

    The results of studies on the effect of near uv light on the yeast Candida guilliermondii are presented. It was shown that certain doses of 313 nm light inactivated the yeast. The detailed affect is shown in the loss of the ability of the cells to form microcolonies and outwardly does not differ from inactivation caused by 254 nm uv. It was concluded that the cell destruction caused by the 313 nm light was not due to damage to DNA. Experiments in which yeast cells were inactivated by 313 nm light before plating on agar and held for some time in a non-nutrient medium permitted observation of recovery of their viability. A difference was shown in the level of repair of yeasts irradiated by 313 nm light (up to 100% recovery) and 254 nm light (60% recovery). The nature of the dependence of the photoprotection on the 313 nm light dose was determined. A decrease in photoprotection was noted, starting with 7x10 -7 einstein/cm 2 , with its complete disappearance upon further dose increase. It is suggested that, in this recovery of the yeast, some other, thus far unknown, mechanism participates. Data were obtained on the survival of yeast irradiated with lethal uv doses. Of special importance, in the authors' opinion, is the fact that, for the photoprotection effect to appear, some time is needed between actions of the 313 and 254 nm lights, which suggests a photoinduced formation in the yeast cells of compounds that protect them from lethal injury

  13. Compact 2050 nm Semiconductor Diode Laser Master Oscillator, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I effort seeks to develop DFB laser master oscillators at the novel wavelength of 12050 nm. Two prototypes will be built, tested, and delivered ....

  14. Stability of a Cu0.7Co2.3O4 electrode during the oxygen evolution reaction for alkaline anion-exchange membrane water electrolysis

    Science.gov (United States)

    Kang, Kyoung Eun; Kim, Chi Ho; Lee, Myung Sup; Jung, Chang Wook; Kim, Yang Do; Lee, Jae Ho

    2018-01-01

    The electrode materials for oxygen evolution, especially non-platinum group metal oxides, have attracted increasing attention. Among the spinel-type transition metal oxides, Cu0.7Co2.3O4 powders were evaluated as a potential replacement for expensive dimensionally stabilized anode materials. Cu0.7Co2.3O4 powder for use as an electrode material for oxygen evolution in an alkaline anion-exchange membrane water electrolyzer was prepared using a thermal decomposition method. The Cu0.7Co2.3O4 powders heat-treated at 250 °C exhibited the same X-ray diffraction patterns without any secondary phases as the Co3O4 spinel structure did. The Cu0.7Co2.3O4 powders heat-treated at 250 °C for 30 minutes showed the smallest mean particle size of approximately 376 nm with the powders having a homogeneous shape and size distribution. The fine powders with a relatively homogeneous size distribution showed a higher current density during the oxygen evolution reaction. The lifetime of the Cu0.7Co2.3O4 electrode was relatively long at a low current density, but was quickly shortened due to physical detachment of the Cu0.7Co2.3O4 powders as the current density was increased. This study showed that the efficiency and the stability of Cu0.7Co2.3O4 powders during the oxygen evolution reaction were related directly to the active electrode area.

  15. 77 FR 63409 - New Mexico Disaster Number NM-00029

    Science.gov (United States)

    2012-10-16

    ... SMALL BUSINESS ADMINISTRATION [Disaster Declaration 13252 and 13253] New Mexico Disaster Number NM... Mexico (FEMA-4079-DR), dated 08/24/2012. Incident: Flooding. Incident Period: 06/22/2012 through 07/12... the President's major disaster declaration for Private Non-Profit organizations in the State of NEW...

  16. Characteristics of Charging and Collection of 10-nm-Class Ultrafine Nanoparticles in an Electrostatic Precipitator

    International Nuclear Information System (INIS)

    Han, Bang Woo; Kim, Hak Joon; Kim, Yong Jin; Song, Dong Keun; Hong, Won Seok; Shin, Wan Ho

    2011-01-01

    The charging of 10-nm-class nanoparticles in an electrostatic precipitator (ESP) according to particle charging ratio has been investigated and compared to the diffusion effect of the nanoparticles. The competition between the charging probability and the diffusion loss effect determines the collection efficiency of nanoparticles in the ESP. The collection efficiency of nanoparticles decreased continuously with decreasing particle diameter. This indicates that the partial charging effect of 10-nm-class nanoparticles is more dominant than their diffusion loss effect in the ESP for nanoparticles in the particle size range of less than 10 nm. The charging ratios based on unipolar diffusion charging calculations were in good agreement with the experimental collection efficiencies for nanoparticles less than 10 nm in diameter

  17. Jeremiah 23:23–24 as polemic against prophets’ views on Yahweh’s presence

    Directory of Open Access Journals (Sweden)

    Wilhelm Wessels

    2016-05-01

    Full Text Available Jeremiah 23:23–24 is a short passage in the cycle of oracles in which the prophet Jeremiah is supposedly in conflict with other prophets in his society. It is possible that this short passage first had an independent existence before it became part of the collection of oracles in 23:9-40 This article argues that as an independent oracle the passage claims that Yahweh is not just a localised god, but an omnipresent God from whom no person can hide. When read as part of the mentioned cycle, it should be regarded as a polemic against a view held by some prophets that Yahweh’s nearness guarantees peace and security. Their domesticated view leads to complacency and disregard. It is argued that Jeremiah opposes their view by stating that Yahweh is also a distant God who is aware of their false and deceitful attempts to provide revelatory knowledge to the people. In this regard chapter 23:23–24 serves as a polemic against so-called false prophets and implies a threat of judgement. Keywords: False prophets, temple, Yahweh's presence, polemic

  18. Cultured Human Fibroblast Biostimulation Using a 940 nm Diode Laser

    Science.gov (United States)

    Illescas-Montes, Rebeca; Melguizo-Rodríguez, Lucía; Manzano-Moreno, Francisco Javier; García-Martínez, Olga; Ruiz, Concepción

    2017-01-01

    Background: Fibroblasts are the main cells involved in regeneration during wound healing. The objective was to determine the effect of 940 nm diode laser on cultured human fibroblasts using different irradiation regimens. Methods: The CCD-1064Sk human epithelial fibroblast cell line was treated with a 940 nm diode laser at different energy doses (power: 0.2–1 W and energy density: 1–7 J/cm2) using different transmission modes (continuous or pulsed). The effect on cell growth at 24 and 72 h post-treatment was examined by measuring the proliferative capacity, the impact on the cell cycle, and the effect on cell differentiation. Results: fibroblast proliferative capacity was increased at 24 and 72 h post-treatment as a function of the energy dose. The greatest increase was observed with a power of 0.2 or 0.5 W and energy density between 1 and 4 J/cm2; no difference was observed between continuous and pulsed modes. There were no significant differences in cell cycle between treated groups and controls. α-actin expression was increased by treatment, indicating enhanced cell differentiation. Conclusion: The 940 nm diode laser has biostimulating effects on fibroblasts, stimulating proliferative capacity and cell differentiation without altering the cell cycle. Further researches are necessary to explore its potential clinical usefulness in wound healing. PMID:28773152

  19. Cultured Human Fibroblast Biostimulation Using a 940 nm Diode Laser

    Directory of Open Access Journals (Sweden)

    Rebeca Illescas-Montes

    2017-07-01

    Full Text Available Background: Fibroblasts are the main cells involved in regeneration during wound healing. The objective was to determine the effect of 940 nm diode laser on cultured human fibroblasts using different irradiation regimens. Methods: The CCD-1064Sk human epithelial fibroblast cell line was treated with a 940 nm diode laser at different energy doses (power: 0.2–1 W and energy density: 1–7 J/cm2 using different transmission modes (continuous or pulsed. The effect on cell growth at 24 and 72 h post-treatment was examined by measuring the proliferative capacity, the impact on the cell cycle, and the effect on cell differentiation. Results: fibroblast proliferative capacity was increased at 24 and 72 h post-treatment as a function of the energy dose. The greatest increase was observed with a power of 0.2 or 0.5 W and energy density between 1 and 4 J/cm2; no difference was observed between continuous and pulsed modes. There were no significant differences in cell cycle between treated groups and controls. α-actin expression was increased by treatment, indicating enhanced cell differentiation. Conclusion: The 940 nm diode laser has biostimulating effects on fibroblasts, stimulating proliferative capacity and cell differentiation without altering the cell cycle. Further researches are necessary to explore its potential clinical usefulness in wound healing.

  20. Diffraction-limited 577 nm true-yellow laser by frequency doubling of a tapered diode laser

    Science.gov (United States)

    Christensen, Mathias; Vilera, Mariafernanda; Noordegraaf, Danny; Hansen, Anders K.; Buß, Thomas; Jensen, Ole B.; Skovgaard, Peter M. W.

    2018-02-01

    A wide range of laser medical treatments are based on coagulation of blood by absorption of the laser radiation. It has, therefore, always been a goal of these treatments to maximize the ratio of absorption in the blood to that in the surrounding tissue. For this purpose lasers at 577 nm are ideal since this wavelength is at the peak of the absorption in oxygenated hemoglobin. Furthermore, 577 nm has a lower absorption in melanin when compared to green wavelengths (515 - 532 nm), giving it an advantage when treating at greater penetration depth. Here we present a laser system based on frequency doubling of an 1154 nm Distributed Bragg Reflector (DBR) tapered diode laser, emitting 1.1 W of single frequency and diffraction limited yellow light at 577 nm, corresponding to a conversion efficiency of 30.5%. The frequency doubling is performed in a single pass configuration using a cascade of two bulk non-linear crystals. The system is power stabilized over 10 hours with a standard deviation of 0.13% and the relative intensity noise is measured to be 0.064 % rms.

  1. Development of a new water sterilization device with a 365 nm UV-LED.

    Science.gov (United States)

    Mori, Mirei; Hamamoto, Akiko; Takahashi, Akira; Nakano, Masayuki; Wakikawa, Noriko; Tachibana, Satoko; Ikehara, Toshitaka; Nakaya, Yutaka; Akutagawa, Masatake; Kinouchi, Yohsuke

    2007-12-01

    Ultraviolet (UV) irradiation is an effective disinfection method. In sterilization equipment, a low-pressure mercury lamp emitting an effective germicidal UVC (254 nm) is used as the light source. However, the lamp, which contains mercury, must be disposed of at the end of its lifetime or following damage due to physical shock or vibration. We investigated the suitability of an ultraviolet light-emitting diode at an output wavelength of 365 nm (UVA-LED) as a sterilization device, comparing with the other wavelength irradiation such as 254 nm (a low-pressure mercury lam) and 405 nm (LED). We used a commercially available UVA-LED that emitted light at the shortest wavelength and at the highest output energy. The new sterilization system using the UVA-LED was able to inactivate bacteria, such as Escherichia coli DH5 alpha, Enteropathogenic E. coli, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella enterica serovar Enteritidis. The inactivations of the bacteria were dependent on the accumulation of UVA irradiation. Taking advantage of the safety and compact size of LED devices, we expect that the UVA-LED sterilization device can be developed as a new type of water sterilization device.

  2. Compact, efficient diode-end-pumped Nd:GdVO4 slab continuous-wave 912-nm laser

    International Nuclear Information System (INIS)

    Liu Huan; Gong Ma-Li

    2012-01-01

    A fiber-coupled laser-diode (LD) end-pumped Nd:GdVO 4 slab continuous-wave (CW) 912-nm laser and an LD bar end-pumped Nd:GdVO 4 slab CW 912-nm laser are both demonstrated in this paper. Using the fiber-coupled LD of end-pumped type, a highest CW 912-nm laser output power of 10.17 W is obtained with a high optical-to-optical conversion efficiency of 24.6% and a slope efficiency of 34.5%. The measured M 2 factors of beam quality in x and y directions are 5.3 and 5.1, respectively. Besides, an LD bar of end-pumped type is used to realize CW 912-nm laser output, which has the advantages of compactness and low cost. When the pump power is 38.8 W, the output power is 8.87 W and the measured M 2 factors of beam quality in x and y directions are 16 and 1.31, respectively. In order to improve the beam quality of the 912-nm laser at x direction, a new quasi-concentric laser resonator will be designed, and an LD bar end-pumped Nd:GdVO 4 slab high-power CW 912-nm TEM 00 laser will be realized in the future. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  3. A diode-pumped Tm:CaYAlO4 laser at 1851 nm

    Science.gov (United States)

    Lan, Jinglong; Guan, Xiaofeng; Xu, Bin; Moncorgé, Richard; Xu, Huiying; Cai, Zhiping

    2017-07-01

    Laser emission at ~1850 nm is of great interest for neural stimulation applications. In this letter, we report on the diode-pumped continuous-wave (CW) and Q-switched (QS) laser operation of Tm:CaYAlO4 at 1851 nm, for the first time to our knowledge. In the CW regime, a maximum output power up to 0.62 W is obtained with a laser slope efficiency of about 18.0%. Using a Cr:ZnSe saturable absorber, QS laser operation is achieved with a maximum average output power of 0.25 W, the narrowest pulse width of 107 ns and the highest repetition rate of 5.85 kHz. The corresponding pulse peak power and pulse energy are about 388 W and 42.8 µJ, respectively. In this Q-switched mode, wavelength tuning is also realized over about 3 nm by slightly tilting the saturable absorber.

  4. 7 CFR 1206.23 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1206.23 Section 1206.23 Agriculture... INFORMATION Mango Promotion, Research, and Information Order Definitions § 1206.23 United States. United... Rico, and the territories and possessions of the United States. ...

  5. Femtosecond all-polarization-maintaining fiber laser operating at 1028 nm

    DEFF Research Database (Denmark)

    Olsson, R.K.; Andersen, T.V.; Leick, Lasse

    2008-01-01

    We present an effective solution for an all-polarization-maintaining modelocked femtosecond fiber laser operating at the central wavelength of 1028 nm. The laser is based on an Yb-doped active fiber. Modelocking is enabled by a semiconductor saturable absorber mirror, and the central wavelength i...... is enforced by a fiber Bragg grating. The laser is self-starting and demonstrates excellent stability gainst Q-switching. Pulse energies reach 13 nJ at 34 MHz repetition rate. External compression leads to near transform-limited pulses of 140 fs.......We present an effective solution for an all-polarization-maintaining modelocked femtosecond fiber laser operating at the central wavelength of 1028 nm. The laser is based on an Yb-doped active fiber. Modelocking is enabled by a semiconductor saturable absorber mirror, and the central wavelength...

  6. Size-resolved fluxes of sub-100-nm particles over forests

    DEFF Research Database (Denmark)

    Pryor, Sara; Barthelmie, Rebecca Jane; Spaulding, A.M.

    2009-01-01

    Dry deposition of atmospheric particles is critically dependent on particle size and plays a key role in dictating the mass and number distributions of atmospheric particles. However, modeling dry deposition is constrained by a lack of understanding of controlling dependencies and accurate size......-resolved observations. We present size-resolved particle number fluxes for sub-100-nm particle diameters (Dp) over a deciduous forest derived using eddy covariance applied to data from a fast mobility particle sizer. The size-resolved particle number fluxes in 18 diameters between 8 and 100 nm were collected during...... leaf-on and are statistically robust. Particle deposition velocities normalized by friction velocity (v d +) are approximately four times smaller than comparable values for coniferous forests reported elsewhere. Comparison of the data with output from a new one-dimensional mechanistic particle...

  7. 670nm photobiomodulation as a novel protection against retinopathy of prematurity: evidence from oxygen induced retinopathy models.

    Directory of Open Access Journals (Sweden)

    Riccardo Natoli

    Full Text Available INTRODUCTION: To investigate the validity of using 670nm red light as a preventative treatment for Retinopathy of Prematurity in two animal models of oxygen-induced retinopathy (OIR. MATERIALS AND METHODS: During and post exposure to hyperoxia, C57BL/6J mice or Sprague-Dawley rats were exposed to 670 nm light for 3 minutes a day (9J/cm². Whole mounted retinas were investigated for evidence of vascular abnormalities, while sections of neural retina were used to quantify levels of cell death using the TUNEL technique. Organs were removed, weighed and independent histopathology examination performed. RESULTS: 670 nm light reduced neovascularisation, vaso-obliteration and abnormal peripheral branching patterns of retinal vessels in OIR. The neural retina was also protected against OIR by 670 nm light exposure. OIR-exposed animals had severe lung pathology, including haemorrhage and oedema, that was significantly reduced in 670 nm+OIR light-exposed animals. There were no significance differences in the organ weights of animals in the 670 nm light-exposed animals, and no adverse effects of exposure to 670 nm light were detected. DISCUSSION: Low levels of exposure to 670 nm light protects against OIR and lung damage associated with exposure to high levels of oxygen, and may prove to be a non-invasive and inexpensive preventative treatment for ROP and chronic lung disease associated with prematurity.

  8. Laboratory Measurements of the 940, 1130, and 1370 nm Water Vapor Absorption Band Profiles

    Science.gov (United States)

    Giver, Lawrence P.; Gore, Warren J.; Pilewskie, P.; Freedman, R. S.; Chackerian, C., Jr.; Varanasi, P.

    2001-01-01

    We have used the solar spectral flux radiometer (SSFR) flight instrument with the Ames 25 meter base-path White cell to obtain about 20 moderate resolution (8 nm) pure water vapor spectra from 650 to 1650 nm, with absorbing paths from 806 to 1506 meters and pressures up to 14 torr. We also obtained a set at 806 meters with several different air-broadening pressures. Model simulations were made for the 940, 1130, and 1370 nm absorption bands for some of these laboratory conditions using the Rothman, et al HITRAN-2000 linelist. This new compilation of HITRAN includes new intensity measurements for the 940 nm region. We compared simulations for our spectra of this band using HITRAN-2000 with simulations using the prior HITRAN-1996. The simulations of the 1130 nm band show about 10% less absorption than we measured. There is some evidence that the total intensity of this band is about 38% stronger than the sum of the HITRAN line intensities in this region. In our laboratory conditions the absorption depends approximately on the square root of the intensity. Thus, our measurements agree that the band is stronger than tabulated in HITRAN, but by about 20%, substantially less than the published value. Significant differences have been shown between Doppler-limited resolution spectra of the 1370 nm band obtained at the Pacific Northwest National Laboratory and HITRAN simulations. Additional new intensity measurements in this region are continuing to be made. We expect the simulations of our SSFR lab data of this band will show the relative importance of improving the HITRAN line intensities of this band for atmospheric measurements.

  9. Removal of an endocrine disrupting chemical (17 alpha-ethinyloestradiol) from wastewater effluent by activated carbon adsorption: Effects of activated carbon type and competitive adsorption

    Energy Technology Data Exchange (ETDEWEB)

    Ifelebuegu, A.O.; Lester, J.N.; Churchley, J.; Cartmell, E. [Cranfield University, Cranfield (United Kingdom). School of Water Science

    2006-12-15

    Granular activated carbon has been extensively used for the adsorption of organic micropollutants for potable water production. In this study the removal of an endocrine disrupting chemical from wastewater final effluent by three types of granular activated carbon (wood, coconut and coal based) has been investigated in batch adsorption experiments and correlated with the removal of chemical oxygen demand (COD), total organic carbon (TOC) and ultraviolet absorbance (UV). The results obtained demonstrated 17 alpha-ethinyloestradiol (EE2) removals of 98.6%, 99.3%, and 96.4% were achieved by the coal based (ACo), coconut based (ACn) and wood based (AWd) carbons respectively at the lowest dose of carbon (0.1 gl{sup -1}). The other adsorbates investigated all exhibited good removal. At an equilibrium concentration of 7 mgl{sup -1} the COD adsorption capacities were 3.16 mg g{sup -1}, 4.8 mg g{sup -1} and 7.1 mg g{sup -1} for the wood, coconut and coal based carbons respectively. Overall, the order of removal efficiency of EE2 and the other adsorbates for the three activated carbons was ACn {gt} ACo {gt} AWd. The adsorption capacities of the carbons were found to be reduced by the effects of other competing adsorbates in the wastewater effluent.

  10. Study on the specificity of yeast cell damage by high-intensity UV radiation (266nm)

    International Nuclear Information System (INIS)

    Burchuladze, T.G.; Frajkin, G.Ya.; Rubin, L.B.

    1981-01-01

    Peculiarities of photoreactivation and photoprotection of the Candida guilliermondii and Candida utilis yeast cells, irradiated with far and near ultraviolet radiation, are considered. New results on the study of the dependence of the cells inactivation degree on the intensity of ultraviolet radiation are presented. The impulse rate density at 266 nm reached 10 10 Ix m -2 xs -1 at the impulse duration of 10 -8 s. Survival curves of the yeast cells during their irradiation with ultraviolet radiation of 266 nm and 254 nm are given. It is shown that with the increase of the irradiation intensity of 266 nm the rates and final levels of photoreactivation decrease. Under the effect of ultraviolet irradiation of high intensity contribution of pyrimidine dimers to the cell inactivation decreases [ru

  11. Large-scale freestanding nanometer-thick graphite pellicles for mass production of nanodevices beyond 10 nm.

    Science.gov (United States)

    Kim, Seul-Gi; Shin, Dong-Wook; Kim, Taesung; Kim, Sooyoung; Lee, Jung Hun; Lee, Chang Gu; Yang, Cheol-Woong; Lee, Sungjoo; Cho, Sang Jin; Jeon, Hwan Chul; Kim, Mun Ja; Kim, Byung-Gook; Yoo, Ji-Beom

    2015-09-21

    Extreme ultraviolet lithography (EUVL) has received much attention in the semiconductor industry as a promising candidate to extend dimensional scaling beyond 10 nm. We present a new pellicle material, nanometer-thick graphite film (NGF), which shows an extreme ultraviolet (EUV) transmission of 92% at a thickness of 18 nm. The maximum temperature induced by laser irradiation (λ = 800 nm) of 9.9 W cm(-2) was 267 °C, due to the high thermal conductivity of the NGF. The freestanding NGF was found to be chemically stable during annealing at 500 °C in a hydrogen environment. A 50 × 50 mm large area freestanding NGF was fabricated using the wet and dry transfer (WaDT) method. The NGF can be used as an EUVL pellicle for the mass production of nanodevices beyond 10 nm.

  12. 14 CFR 23.239 - Spray characteristics.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Spray characteristics. 23.239 Section 23.239 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Handling Characteristics § 23.239 Spray characteristics. Spray may not dangerously obscure the vision of...

  13. 28 CFR 23.30 - Funding guidelines.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Funding guidelines. 23.30 Section 23.30 Judicial Administration DEPARTMENT OF JUSTICE CRIMINAL INTELLIGENCE SYSTEMS OPERATING POLICIES § 23.30 Funding guidelines. The following funding guidelines shall apply to all Crime Control Act funded...

  14. Modeling of filamentation damage induced in silica by 351-nm laser pulses

    International Nuclear Information System (INIS)

    Milam, D.; Manes, K.R.; Williams, W.H.

    1996-01-01

    A major risk factor that must be considered in design of the National Ignition Facility is the possibility for catastrophic self-focusing of the 351-nm beam in the silica optical components that are in the final section of the laser. Proposed designs for the laser are analyzed by the beam-propagation code PROP92. A 351-nm self-focusing experiment, induction of tracking damage, was done to provide data for validation of this code. The measured self-focusing lengths were correctly predicted by the code

  15. NM-Net Gigabit-based Implementation on Core Network Facilities and Network Design Hierarchy

    International Nuclear Information System (INIS)

    Raja Murzaferi Raja Moktar; Mohd Fauzi Haris; Siti Nurbahyah Hamdan

    2011-01-01

    Nuclear Malaysia computing network or NM the main backbone of internet working on operational staffs. Main network operating center or NOC is situated in Block 15 and linkup via fiber cabling to adjacent main network blocks (18, 29, 11 connections. Pre 2009 infrastructure; together to form the core networking switch. of the core network infrastructure were limited by the up link between core switches that is the Pair (UTP) Category 6 Cable. Furthermore, majority of the networking infrastructure throughout the agency were mainly built with Fast Ethernet Based specifications to date. With current research and operational tasks highly dependent on IT infrastructure that is being enabled through NM-Net, the performance NM-Net implementing gigabit-based networking system achieve optimal performance of internet networking services in the agency thus catalyze initiative. (author)

  16. Novel treatment of Hori′s nevus: A combination of fractional nonablative 2,940-nm Er:YAG and low-fluence 1,064-nm Q-switched Nd:YAG laser

    Directory of Open Access Journals (Sweden)

    Brian Wei Cheng Anthony Tian

    2015-01-01

    Full Text Available Objective: To demonstrate a combination laser therapy to treat Hori′s nevus. Design: A prospective study. Setting: A Singapore-based clinic. Participants: Five female patients, aged 30-46 years, with bilateral malar Hori′s nevus. Measurements: Photographs were taken before treatment and 1 month after laser treatment was completed. These were graded by three independent physicians. The patients were also asked to grade their treatment response subjectively. They were followed up for a total of 3 months after laser treatment to monitor recurrence. Materials and Methods: The fractional nonablative 2,940-nm Er:YAG laser with a fluence of 0.7 J/cm 2, spot size 12 mm, and frequency 15 Hz was used to perform a full-face single-pass treatment. Subsequently, a second pass and third pass over Hori′s nevi were done bilaterally till the clinical endpoint of skin whitening. The 1,064-nm Q-switched (QS Nd:YAG at a fluence of 2.0 J/cm 2 , frequency 2 Hz, and 4-mm spot size was used to deliver multiple passes over Hori′s nevus till erythema with mild petechiae appeared. We repeated the treatment once a week for 3 more consecutive weeks. Results: All five patients had above 80% improvement in their pigmentation and two (skin type III achieved complete 100% clearance. Based on the patients′ subjective assessments, all five of them expressed satisfaction and felt that their pigmentation had improved. There were no complications noted. Conclusion: The fractional nonablative 2940 nm Er:YAG laser and Q-switched 1064nm laser Nd:YAG combination is an effective and safe treatment for Hori′s nevus.

  17. Effects of 1,540-nm Fractional Nonablative Erbium and 2,940-nm Fractional Ablative Erbium on p53 Epidermal Expression After 3 months: A Split-Face Interventional Study.

    Science.gov (United States)

    Borges, Juliano; Araújo, Luciana; de Oliveira, Rodrigo P B; Manela-Azulay, Monica

    2018-04-16

    Expression of p53 by keratinocytes may be important in the pathogenesis of skin cancer induced by ultraviolet light. We used side-by-side nonablative and ablative erbium fractional laser resurfacing to assess the effects on expression of p53 by facial keratinocytes. Ten female patients (age range, 50-63 years) with Fitzpatrick skin Types I-IV and clinical signs of photoaging underwent erbium fractional laser resurfacing (nonablative, 1,540-nm; ablative, 2,940-nm) on opposite sides of the face. Skin biopsies were obtained before treatment and 3 months after treatment for comparison with control biopsies of face and inner arm, quantifying p53 in immunostained tissue sections. Only ablative (2,940-nm) treatments produced a statistically significant reduction in p53 scoring after 3 months. The histologic appearance of skin after ablative resurfacing more closely resembled inner arm skin (rather than facial skin) of control subjects. Epidermal repopulation with p53-negative keratinocytes through ablative erbium fractional laser resurfacing may diminish the risk of eventual malignancy in photoaged skin.

  18. 14 CFR 23.659 - Mass balance.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Mass balance. 23.659 Section 23.659 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... Surfaces § 23.659 Mass balance. The supporting structure and the attachment of concentrated mass balance...

  19. 45 CFR 1304.23 - Child nutrition.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Child nutrition. 1304.23 Section 1304.23 Public... AGENCIES Early Childhood Development and Health Services § 1304.23 Child nutrition. (a) Identification of... into account staff and family discussions concerning: (1) Any relevant nutrition-related assessment...

  20. 29 CFR 1905.23 - Prehearing conferences.

    Science.gov (United States)

    2010-07-01

    ...-STEIGER OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 Hearings § 1905.23 Prehearing conferences. (a... 29 Labor 5 2010-07-01 2010-07-01 false Prehearing conferences. 1905.23 Section 1905.23 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR...