WorldWideScience

Sample records for national scada test

  1. Communication Test for ‘MatrikonOPC Server for SCADA DNP 3’ with RTDS

    DEFF Research Database (Denmark)

    Wu, Qiuwei; Cha, Seung-Tae; Saleem, Arshad

    2010-01-01

    The purpose of the communication test for ‘MatrikonOPC server for SCADA DNP 3’ with RTDS is to verify the data exchange between the ‘MatrikonOPC server for SCADA DNP 3’ and the RTDS using the DNP 3 protocol.The communication test is part of the work for the ‘Wind in Øresund’ project. The objective...... of the ‘Wind in Øresund’ project is to build a demonstration and education system of power system operation and control with a RTDS and a SCADA system....

  2. Using cyber vulnerability testing techniques to expose undocumented security vulnerabilities in DCS and SCADA equipment

    International Nuclear Information System (INIS)

    Pollet, J.

    2006-01-01

    This session starts by providing an overview of typical DCS (Distributed Control Systems) and SCADA (Supervisory Control and Data Acquisition) architectures, and exposes cyber security vulnerabilities that vendors never admit, but are found through a comprehensive cyber testing process. A complete assessment process involves testing all of the layers and components of a SCADA or DCS environment, from the perimeter firewall all the way down to the end devices controlling the process, including what to look for when conducting a vulnerability assessment of real-time control systems. The following systems are discussed: 1. Perimeter (isolation from corporate IT or other non-critical networks) 2. Remote Access (third Party access into SCADA or DCS networks) 3. Network Architecture (switch, router, firewalls, access controls, network design) 4. Network Traffic Analysis (what is running on the network) 5. Host Operating Systems Hardening 6. Applications (how they communicate with other applications and end devices) 7. End Device Testing (PLCs, RTUs, DCS Controllers, Smart Transmitters) a. System Discovery b. Functional Discovery c. Attack Methodology i. DoS Tests (at what point does the device fail) ii. Malformed Packet Tests (packets that can cause equipment failure) iii. Session Hijacking (do anything that the operator can do) iv. Packet Injection (code and inject your own SCADA commands) v. Protocol Exploitation (Protocol Reverse Engineering / Fuzzing) This paper will provide information compiled from over five years of conducting cyber security testing on control systems hardware, software, and systems. (authors)

  3. Using cyber vulnerability testing techniques to expose undocumented security vulnerabilities in DCS and SCADA equipment

    Energy Technology Data Exchange (ETDEWEB)

    Pollet, J. [PlantData Technologies, Inc., 1201 Louisiana Street, Houston, TX 77002 (United States)

    2006-07-01

    This session starts by providing an overview of typical DCS (Distributed Control Systems) and SCADA (Supervisory Control and Data Acquisition) architectures, and exposes cyber security vulnerabilities that vendors never admit, but are found through a comprehensive cyber testing process. A complete assessment process involves testing all of the layers and components of a SCADA or DCS environment, from the perimeter firewall all the way down to the end devices controlling the process, including what to look for when conducting a vulnerability assessment of real-time control systems. The following systems are discussed: 1. Perimeter (isolation from corporate IT or other non-critical networks) 2. Remote Access (third Party access into SCADA or DCS networks) 3. Network Architecture (switch, router, firewalls, access controls, network design) 4. Network Traffic Analysis (what is running on the network) 5. Host Operating Systems Hardening 6. Applications (how they communicate with other applications and end devices) 7. End Device Testing (PLCs, RTUs, DCS Controllers, Smart Transmitters) a. System Discovery b. Functional Discovery c. Attack Methodology i. DoS Tests (at what point does the device fail) ii. Malformed Packet Tests (packets that can cause equipment failure) iii. Session Hijacking (do anything that the operator can do) iv. Packet Injection (code and inject your own SCADA commands) v. Protocol Exploitation (Protocol Reverse Engineering / Fuzzing) This paper will provide information compiled from over five years of conducting cyber security testing on control systems hardware, software, and systems. (authors)

  4. Security and SCADA protocols

    International Nuclear Information System (INIS)

    Igure, V. M.; Williams, R. D.

    2006-01-01

    Supervisory control and data acquisition (SCADA) networks have replaced discrete wiring for many industrial processes, and the efficiency of the network alternative suggests a trend toward more SCADA networks in the future. This paper broadly considers SCADA to include distributed control systems (DCS) and digital control systems. These networks offer many advantages, but they also introduce potential vulnerabilities that can be exploited by adversaries. Inter-connectivity exposes SCADA networks to many of the same threats that face the public internet and many of the established defenses therefore show promise if adapted to the SCADA differences. This paper provides an overview of security issues in SCADA networks and ongoing efforts to improve the security of these networks. Initially, a few samples from the range of threats to SCADA network security are offered. Next, attention is focused on security assessment of SCADA communication protocols. Three challenges must be addressed to strengthen SCADA networks. Access control mechanisms need to be introduced or strengthened, improvements are needed inside of the network to enhance security and network monitoring, and SCADA security management improvements and policies are needed. This paper discusses each of these challenges. This paper uses the Profibus protocol as an example to illustrate some of the vulnerabilities that arise within SCADA networks. The example Profibus security assessment establishes a network model and an attacker model before proceeding to a list of example attacks. (authors)

  5. Cyber Security in Industrial Control Systems and SCADA Applications: Modbus TCP Protocol Example

    Directory of Open Access Journals (Sweden)

    Erdal IRMAK

    2017-12-01

    Full Text Available Electrical energy generation, transmission and distribution systems are evaluated in terms of national security dimension and defined as critical infrastructures. Monitoring and controlling of these systems is provided by Industrial Control Systems (ICS or Supervisory Control and Data Acquisition (SCADA systems. According to the latest advances in communication and internet technology, ICS/SCADA systems have started to become integrated with these systems. As a result of this situation, current or existing vulnerabilities in information and communication technology affect to SCADA systems directly. Therefore, this paper focuses on the cyber security of ICS/SCADA systems. It has been proved that the lack of authentication detected in Modbus TCP protocol, one of the most used in ICS/SCADA systems, can be exploited. In order to solve this security issue, a software is developed using the Python programming language for blocking or mitigating the cyber attacks. The proposed solution is subjected to several tests and results show that the attacks can be prevented successfully. Thus, it is considered that the proposed work will contribute to the security of ICS/SCADA systems and the industrial protocols using for communicating these systems.

  6. SCADA Architecture for Natural Gas plant

    Directory of Open Access Journals (Sweden)

    Turc Traian

    2009-12-01

    Full Text Available The paper describes the Natural Gas Plant SCADA architecture. The main purpose of SCADA system is remote monitoring and controlling of any industrial plant. The SCADA hardware architecture is based on multi-dropping system allowing connecting a large number of different fiels devices. The SCADA Server gathers data from gas plant and stores data to a MtSQL database. The SCADA server is connected to other SCADA client application offers a intuitive and user-friendly HMI. The main benefit of using SCADA is real time displaying of gas plant state. The main contriobution of the authors consists in designing SCADA architecture based on multi-dropping system and Human Machine Interface.

  7. Low-Cost SCADA System Using Arduino and Reliance SCADA for a Stand-Alone Photovoltaic System

    Directory of Open Access Journals (Sweden)

    Ibrahim Allafi

    2018-01-01

    Full Text Available SCADA (supervisory control and data acquisition systems are currently employed in many applications, such as home automation, greenhouse automation, and hybrid power systems. Commercial SCADA systems are costly to set up and maintain; therefore those are not used for small renewable energy systems. This paper demonstrates applying Reliance SCADA and Arduino Uno on a small photovoltaic (PV power system to monitor the PV current, voltage, and battery, as well as efficiency. The designed system uses low-cost sensors, an Arduino Uno microcontroller, and free Reliance SCADA software. The Arduino Uno microcontroller collects data from sensors and communicates with a computer through a USB cable. Uno has been programmed to transmit data to Reliance SCADA on PC. In addition, Modbus library has been uploaded on Arduino to allow communication between the Arduino and our SCADA system by using MODBUS RTU protocol. The results of the experiments demonstrate that SCADA works in real time and can be effectively used in monitoring a solar energy system.

  8. Power system SCADA and smart grids

    CERN Document Server

    Thomas, Mini S

    2015-01-01

    Power System SCADA and Smart Grids brings together in one concise volume the fundamentals and possible application functions of power system supervisory control and data acquisition (SCADA). The text begins by providing an overview of SCADA systems, evolution, and use in power systems and the data acquisition process. It then describes the components of SCADA systems, from the legacy remote terminal units (RTUs) to the latest intelligent electronic devices (IEDs), data concentrators, and master stations, as well as:Examines the building and practical implementation of different SCADA systemsOf

  9. EMS applications integration in a SCADA; Integracion de aplicaciones EMS en un SCADA

    Energy Technology Data Exchange (ETDEWEB)

    Roses, Rodolfo; Colome, D.G.; Orduna, E.; Vega, C. de la; Camisay, G. [Universidad Nacional de San Juan (Argentina). Inst. de Energia Electrica]. E-mail: roses@iee.unsj.edu.ar

    2001-07-01

    This paper presents the methodology to integrate EMS (Energy Management System) functions in a SCADA system (System Control and Data Acquisition). The implementation methodology of the EMS applications has included the design and database implementation, EMS-SCADA communication, results presentation, logics definition of execution and processing ways. The applications portability characteristics allow integration with different SCADA system with some adaptations on the data communication interface. Thus, a open system has been obtained and implemented successfully in the control center of an Argentine 132 kV network.

  10. Comparison between commercial and open-source SCADA packages-A case study

    International Nuclear Information System (INIS)

    Barana, O.; Barbato, P.; Breda, M.; Capobianco, R.; Luchetta, A.; Molon, F.; Moressa, M.; Simionato, P.; Taliercio, C.; Zampiva, E.

    2010-01-01

    SPIDER (Source for the Production of Ions of Deuterium Extracted from Rf plasma) is a new experimental device under development at Consorzio RFX aimed at providing a full-scale ion source prototype for MITICA (Megavolt ITer Injector and Concept Advance), the experiment devoted at supplying a full-scale prototype of the ITER Heating Neutral Beam Injector (HNB). Both experimental devices will be hosted in a new facility known as PRIMA (Padova Research on Injectors Megavolt Accelerated). The correct operation of SPIDER and MITICA will be guaranteed by process automation and plant monitoring that will be implemented using suitable controllers (cycle time greater than 10 ms) in conjunction with appropriate SCADA (Supervisory Control And Data Acquisition) software. This paper presents the tests performed at Consorzio RFX to evaluate commercial and open-source SCADA packages and prepare a technical base for the selection of the SCADA system for SPIDER. Two commercial solutions and two open-source solutions (EPICS and TANGO) were investigated. The typical test-bed was represented by a SCADA system exchanging data with a PLC (Programmable Logic Controller). The case study consisted of: (a) the development of a minimal panel provided with fields for setting parameters and of a trend window; (b) the set-up of two kinds of communication, a direct connection between the SCADA and the PLC and an indirect one by means of an OPC (Object Linking and Embedding for Process Control) server. The communication performance was evaluated measuring the network traffic with a fixed number of data variables exchanged and different polling cycle times. The conclusions show that the final choice of a SCADA package for SPIDER will be between one commercial SCADA and EPICS. This choice will not depend uniquely on the results of the tests, but will be also dictated by the early schedule of the SPIDER operations.

  11. Flow whitelisting in SCADA networks

    NARCIS (Netherlands)

    Barbosa, Rafael Ramos Regis; Sadre, Ramin; Pras, Aiko

    2013-01-01

    Supervisory control and data acquisition (SCADA) networks are commonly deployed in large industrial facilities. Modern SCADA networks are becoming more vulnerable to cyber attacks due to the common use of standard communications protocols and increased interconnections with corporate networks and

  12. Flow whitelisting in SCADA networks

    NARCIS (Netherlands)

    Barbosa, Rafael Ramos Regis; Pras, Aiko; Sadre, Ramin

    Supervisory Control And Data Acquisition (SCADA) networks are commonly deployed to aid the operation of large industrial facilities. Modern SCADA networks are becoming more vulnerable to network attacks, due to the now common use of standard communication protocols and increased interconnection to

  13. Flow Whitelisting in SCADA Networks

    NARCIS (Netherlands)

    Barbosa, R.R.R.; Pras, Aiko; Sadre, R.

    2013-01-01

    Supervisory Control And Data Acquisition (SCADA) networks are commonly deployed to aid the operation of large industrial facilities. Modern SCADA networks are becoming more vulnerable to network attacks, due to the now common use of standard communication protocols and increased interconnection to

  14. Industrial Control Systems/SCADA systems risk assessment in the energy sector

    Science.gov (United States)

    Falodun, Babatunde

    The energy sector is one of the most critical components of our national infrastructure. It not only provides the electrical power and petroleum required to run day-to-day operations and mechanisms in society, it's also an important element that directly impacts the economy with regard to growth and stability. Industrial Control Systems (ICS) /Supervisory Control and Data Acquisition Systems (SCADA) are computerized mechanisms, they are both software and hardware that are used to control real time processes and operations in power plants and oil production facilities. A significant attack on these control systems that leads to widespread disruption of energy could result in catastrophic consequences for any major city and even the nation. This research paper explores cyber threats and vulnerabilities faced by ICS/SCADA systems in the energy sector and also highlights possible outcomes of a successful breach. Furthermore, the research underscores mitigation strategies that could be used to prevent and respond to an attack. Keywords: Cybersecurity, SCADA, Cyber Attacks, Threats, Vulnerabilities, Risk Assessment, Dr. Albert Orbinati.

  15. Idaho National Laboratory Supervisory Control and Data Acquisition Intrusion Detection System (SCADA IDS)

    Energy Technology Data Exchange (ETDEWEB)

    Jared Verba; Michael Milvich

    2008-05-01

    Current Intrusion Detection System (IDS) technology is not suited to be widely deployed inside a Supervisory, Control and Data Acquisition (SCADA) environment. Anomaly- and signature-based IDS technologies have developed methods to cover information technology-based networks activity and protocols effectively. However, these IDS technologies do not include the fine protocol granularity required to ensure network security inside an environment with weak protocols lacking authentication and encryption. By implementing a more specific and more intelligent packet inspection mechanism, tailored traffic flow analysis, and unique packet tampering detection, IDS technology developed specifically for SCADA environments can be deployed with confidence in detecting malicious activity.

  16. Design Private Cloud of Oil and Gas SCADA System

    Directory of Open Access Journals (Sweden)

    Liu Miao

    2014-05-01

    Full Text Available SCADA (Supervisory Control and Data Acquisition system is computer control system based on supervisory. SCADA system is very important to oil and gas pipeline engineering. Cloud computing is fundamentally altering the expectations for how and when computing, storage and networking resources should be allocated, managed and consumed. In order to increase resource utilization, reliability and availability of oil and gas pipeline SCADA system, the SCADA system based on cloud computing is proposed in the paper. This paper introduces the system framework of SCADA system based on cloud computing and the realization details about the private cloud platform of SCADA system.

  17. Access Control Management for SCADA Systems

    Science.gov (United States)

    Hong, Seng-Phil; Ahn, Gail-Joon; Xu, Wenjuan

    The information technology revolution has transformed all aspects of our society including critical infrastructures and led a significant shift from their old and disparate business models based on proprietary and legacy environments to more open and consolidated ones. Supervisory Control and Data Acquisition (SCADA) systems have been widely used not only for industrial processes but also for some experimental facilities. Due to the nature of open environments, managing SCADA systems should meet various security requirements since system administrators need to deal with a large number of entities and functions involved in critical infrastructures. In this paper, we identify necessary access control requirements in SCADA systems and articulate access control policies for the simulated SCADA systems. We also attempt to analyze and realize those requirements and policies in the context of role-based access control that is suitable for simplifying administrative tasks in large scale enterprises.

  18. SCADA system vulnerabilities to cyber attack

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, W. T. [Cyber Security Consulting (Canada)

    2004-10-01

    The susceptibility to terrorist attacks of computer-based supervisory control (SCADA) systems that are used to monitor and control water distribution systems, oil and gas pipelines and the electrical grid, is discussed. The discussion includes ways in which SCADA systems may be attacked and remedial actions that may be taken to reduce or eliminate the possibility of such attacks. Attacks may take the form of causing the system to generate false data to divert attention from impending system disasters, or commandeer the system to seriously disable it, or cause damage to the process or equipment being controlled by sending improper control commands. SCADA systems are also vulnerable to internal threats, either from an accidental action that results in damage, or an intentional action, as for example by a disgruntled employee, or ex-employee, usually by way of reprogramming an RTU or PLC by accessing the polling/communications circuit. Recent SCADA systems are much more susceptible to concerted cyber attacks because of the adoption of IT technologies and standards into the design of such systems. (Older systems are more likely to be unique designs, hence less susceptible to attack). As far as protection of SCADA systems is concerned, there are no technologies that would prevent a technologically sophisticated terrorist or disgruntled employee from doing major damage to the system, however, the IT world has developed a range of technologies for the protection of IT assets, and many of these same technologies can also be used to safeguard modern SCADA systems.

  19. Design and Implementation of SCADA Based Induction Motor Control

    OpenAIRE

    Pampashree; Dr. Md.Fakhruddin Ansari

    2014-01-01

    The introduction of Supervisory Control and Data Acquisition (SCADA) system has been discussed in details. Network components, functionality, generation and features of SCADA has been discussed in details in this paper. Application and uses of SCADA system in different fields of engineering have also been mentioned. Also the working of the software components and development in SCADA has been explained with merits and demerits of the software. Programmable Logic Controller ...

  20. Upgradation in SCADA and PLC of existing LN_2 control system for SST-1

    International Nuclear Information System (INIS)

    Panchal, Pradip; Mahesuria, Gaurang; Panchal, Rohit; Patel, Rakesh; Sonara, Dashrath; Pitroda, Dipen; Nimavat, Hiren; Tanna, Vipul; Pradhan, Subrata

    2016-01-01

    Highlights: • The control system of LN_2 Management System of SST-1 is designed on PLC and SCADA. • The implementation and results of up-gradation in PLC and SCADA are reported. • The up-gradation in PLC and SCADA has improved the reliability & availability of SST-1 LN_2 system. - Abstract: Helium Refrigerator/Liquefier system of Steady State Superconducting Tokamak (SST-1) incorporates Liquid Nitrogen (LN_2) pre-cooling system. LN_2 is used for 80 K thermal shields of SST-1, current feeder system and integrated flow distribution and control system. The LN_2 management system is distributed system and requires automatic control. Initially LN_2 control system had Citect based Supervisory Control and Data Acquisition (SCADA) and Koyo make Programmable Logic Controller (PLC). With the passage of time and due to unavailability of their hardware, it is being obsoleted. So, the requirements of new PLC and SCADA systems have been envisaged to make uninterruptable operation of SST-1 cryogenic system. Therefore, Wonderware SCADA and Schneider Electric make PLC is programmed to replace Citect SCADA and Koyo PLC. New control features have been added in upgraded control system for better management of LN_2 system. This upgradation of SCADA and PLC is completed, tested successfully and in operation. Operational performance highlights of the new upgraded system are presented in this paper.

  1. Research and Application of a SCADA System for a Microgrid

    Directory of Open Access Journals (Sweden)

    Shuangshuang Li

    2017-03-01

    Full Text Available An effective Supervisory Control and Data Acquisition (SCADA system can improve the reliability, safety and economic benefits of a microgrid operation. In this research, the lower central controller and upper WEB (World Wide Web monitoring system are connected by the SCADA system, which is the hub of a microgrid intelligent monitoring platform. This system contains a set of specific functions programmed by Java as a middleware and can provide communication and control functions between the central controller and the upper monitoring system. For the sake of security and stability of the microgrid, the SCADA system realizes business processing on real-time data acquisition and storage, load balancing and resource recovery, concurrent security processing, and control instruction parsing and transmission. All those functions were tested and verified in actual operation.

  2. SCADA System of Physicochemical Variables in a Mixture Separator

    Directory of Open Access Journals (Sweden)

    Claudia Marcela Bustamante Álvarez

    2015-01-01

    Full Text Available This paper presents the results of a research project developed by professors from Universidad de los Llanos and Colciencias Young Researcher, whose aim is to implement the necessary instrumentation to monitor and control with a SCADA system of physicochemical variables for a mixture separation process in oily water, thereby seeking to minimize environmental damage in water sources. The project was divided into three methodological stages: the establishment of interest variables, the design and implementation of the SCADA system, and the testing for results validation. This system has sensors to capture and transfer data to a PLC (S71200 for each of the system variables such as temperature, level, flow and pH. It also has HMI interface for interacting with the system. The SCADA system greatly facilitates process monitoring and establishes the possibility of remote action, just by providing the programmable logic controller (PLC to an Ethernet network.

  3. Design Private Cloud of Oil and Gas SCADA System

    OpenAIRE

    Liu Miao; Mancang Yuan; Guodong Li

    2014-01-01

    SCADA (Supervisory Control and Data Acquisition) system is computer control system based on supervisory. SCADA system is very important to oil and gas pipeline engineering. Cloud computing is fundamentally altering the expectations for how and when computing, storage and networking resources should be allocated, managed and consumed. In order to increase resource utilization, reliability and availability of oil and gas pipeline SCADA system, the SCADA system based on cloud computing is propos...

  4. Augmented Reality Applications for Substation Management by Utilizing Standards-Compliant SCADA Communication

    Directory of Open Access Journals (Sweden)

    Miro Antonijević

    2018-03-01

    Full Text Available Most electrical substations are remotely monitored and controlled by using Supervisory Control and Data Acquisition (SCADA applications. Current SCADA systems have been significantly enhanced by utilizing standardized communication protocols and the most prominent is the IEC 61850 international standard. These enhancements enable improvements in different domains of SCADA systems such as communication engineering, data management and visualization of automation process data in SCADA applications. Process data visualization is usually achieved through Human Machine Interface (HMI screens in substation control centres. However, this visualization method sometimes makes supervision, control and maintenance procedures executed by engineers slow and error-prone because it separates equipment from its automation data. Augmented reality (AR and mixed reality (MR visualization techniques have matured enough to provide new possibilities of displaying relevant data wherever needed. This paper presents a novel methodology for visualizing process related SCADA data to enhance and facilitate human-centric activities in substations such as regular equipment maintenance. The proposed solution utilizes AR visualization techniques together with standards-based communication protocols used in substations. The developed proof-of-concept AR application that enables displaying SCADA data on the corresponding substation equipment with the help of AR markers demonstrates originality and benefits of the proposed visualization method. Additionally, the application enables displaying widgets and 3D models of substation equipment to make the visualization more user-friendly and intuitive. The visualized SCADA data needs to be refreshed considering soft real-time data delivery restrictions. Therefore, the proposed solution is thoroughly tested to demonstrate the applicability of proposed methodology in real substations.

  5. Behavioral Profiling of Scada Network Traffic Using Machine Learning Algorithms

    Science.gov (United States)

    2014-03-27

    Acquisition ( SCADA ) System Overview SCADA systems control and monitor processes for water distribution, oil and natural gas pipelines , electrical...the desire for remote control and monitoring of industrial processes. The ability to identify SCADA devices on a mixed traffic network with zero...optimal attribute subset, while maintaining the desired TPR of .99 for SCADA network traffic. The attributes and ML algorithms chosen for

  6. Upgradation in SCADA and PLC of existing LN{sub 2} control system for SST-1

    Energy Technology Data Exchange (ETDEWEB)

    Panchal, Pradip, E-mail: pradip@ipr.res.in; Mahesuria, Gaurang; Panchal, Rohit; Patel, Rakesh; Sonara, Dashrath; Pitroda, Dipen; Nimavat, Hiren; Tanna, Vipul; Pradhan, Subrata

    2016-11-15

    Highlights: • The control system of LN{sub 2} Management System of SST-1 is designed on PLC and SCADA. • The implementation and results of up-gradation in PLC and SCADA are reported. • The up-gradation in PLC and SCADA has improved the reliability & availability of SST-1 LN{sub 2} system. - Abstract: Helium Refrigerator/Liquefier system of Steady State Superconducting Tokamak (SST-1) incorporates Liquid Nitrogen (LN{sub 2}) pre-cooling system. LN{sub 2} is used for 80 K thermal shields of SST-1, current feeder system and integrated flow distribution and control system. The LN{sub 2} management system is distributed system and requires automatic control. Initially LN{sub 2} control system had Citect based Supervisory Control and Data Acquisition (SCADA) and Koyo make Programmable Logic Controller (PLC). With the passage of time and due to unavailability of their hardware, it is being obsoleted. So, the requirements of new PLC and SCADA systems have been envisaged to make uninterruptable operation of SST-1 cryogenic system. Therefore, Wonderware SCADA and Schneider Electric make PLC is programmed to replace Citect SCADA and Koyo PLC. New control features have been added in upgraded control system for better management of LN{sub 2} system. This upgradation of SCADA and PLC is completed, tested successfully and in operation. Operational performance highlights of the new upgraded system are presented in this paper.

  7. Pipelines, utilities plan over 150 scada systems

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper reports that North American pipelines and utilities will spend more than $170 million on new or upgraded supervisory control and data acquisition (scada) systems during the 30-month period that commenced Sept. 1. Another $12.5 million will be spent on peripherals and consulting. Among the 699 various projects to be implemented during the period, companies will install 151 scada systems, add 154 remote-terminal units (RTUs) to existing scada units, and install 196 communications systems. Scada systems are computerized hardware and software systems that perform a set of monitoring and control functions. In gas utilities, these systems perform functions normally associated with gas transmission and distribution as well as production plant process control. In gas and oil pipelines, the systems perform these functions as well as such specialized functions as batch tracking, leak detection, and gas load flow

  8. Key management issue in SCADA networks: A review

    Directory of Open Access Journals (Sweden)

    Abdalhossein Rezai

    2017-02-01

    Full Text Available Supervisory Control And Data Acquisition (SCADA networks have a vital role in Critical Infrastructures (CIs such as public transports, power generation systems, gas, water and oil industries, so that there are concerns on security issues in these networks. The utilized Remote Terminal Units (RTUs and Intelligence Electronic Devices (IEDs in these networks have resource limitations, which make security applications a challenging issue. Efficient key management schemes are required besides lightweight ciphers for securing the SCADA communications. Many key management schemes have been developed to address the tradeoff between SCADA constrain and security, but which scheme is the most effective is still debatable. This paper presents a review of the existing key management schemes in SCADA networks, which provides directions for further researches in this field.

  9. What's under the hood? Improving SCADA security with process awareness

    NARCIS (Netherlands)

    Chromik, Justyna Joanna; Remke, Anne Katharina Ingrid; Haverkort, Boudewijn R.H.M.

    2016-01-01

    SCADA networks are an essential part of monitoring and controlling physical infrastructures, such as the power grid. Recent news item show that tampering with the data exchanged in a SCADA network occurs and has severe consequences. A possible way of improving the security of SCADA networks is to

  10. Test suite for the archiver of a SCADA system

    CERN Document Server

    Voitier, Axel

    2009-01-01

    Topic: The group responsible for providing the main control system applications for all machines at CERN has to validate that every piece of the control systems used will be reliable and fully functional when the LHC and its experiments will do collisions of particles. CERN use PVSS from ETM/Siemens for the SCADA part of its control systems. This software has a component dedicated to archive into a centralised Oracle database values and commands of tenth of thousands hardware devices. This component, named RDB, has to be tested and validated in terms of functionality and performance. The need is high for that because archiving is a critical part of the control systems. In case of an incident on one of the machine, it will be unacceptable to not benefit of archiving the machine context at this moment just because of a bug in RDB. Bugs have to be spotted and reported to ETM. Results: The proposed solution is an extensible automatic tester able to evaluate currently around 160 cases of potential bugs. Since the ...

  11. An Integrated Dynamic Weighing System Based on SCADA

    Directory of Open Access Journals (Sweden)

    Piotr Bazydło

    2015-01-01

    Full Text Available A prototyped dynamic weighing system has been presented which integrates together three advanced software environments: MATLAB, LabVIEW and iFIX SCADA. They were used for advanced signal processing, data acquisition, as well as visualization and process control. Dynamic weighing is a constantly developing field of metrology. Because of the highly complicated structure of any electronic weighing module, it is vulnerable to many sources of environmental disturbances. For this reason, there is a lot of research concerned with weighing signal processing, mechanical matters and functionality of the system. In the paper, some issues connected with dynamic weighing have been presented, and the necessity of implementing signal processing methods has been discussed. Implementation of this feature is impossible in the majority of SCADA systems. The integration of the three environments mentioned above is an attempt to create an industrial system with capabilities to deal with major dynamic weighing problems. It is innovative because it connects the industrial SCADA, laboratory/industrial product LabVIEW and MATLAB. In addition, the algorithms responsible for process control and data exchange are presented. The paper includes a description of the capabilities, performance tests, as well as benefits and drawbacks, of the system. The outcome of the research is a prototyped system and evaluation of its usefulness. (original abstract

  12. Whitelists Based Multiple Filtering Techniques in SCADA Sensor Networks

    Directory of Open Access Journals (Sweden)

    DongHo Kang

    2014-01-01

    Full Text Available Internet of Things (IoT consists of several tiny devices connected together to form a collaborative computing environment. Recently IoT technologies begin to merge with supervisory control and data acquisition (SCADA sensor networks to more efficiently gather and analyze real-time data from sensors in industrial environments. But SCADA sensor networks are becoming more and more vulnerable to cyber-attacks due to increased connectivity. To safely adopt IoT technologies in the SCADA environments, it is important to improve the security of SCADA sensor networks. In this paper we propose a multiple filtering technique based on whitelists to detect illegitimate packets. Our proposed system detects the traffic of network and application protocol attacks with a set of whitelists collected from normal traffic.

  13. SCADA system for islanded DC microgrids

    DEFF Research Database (Denmark)

    Xiao, Zhao xia; Zhijun, Guo; Guerrero, Josep M.

    2017-01-01

    intelligent modules and different communication techniques. The developed SCADA system can monitor real-time parameters such as voltages, currents, or powers, and can store the important parameters into the database. Users can get historical data realistically and effectively through SQL access. When some...... the action of the slaves. This way, it implements the combination of required monitoring and control functions. The SCADA system includes an energy management system (EMS), monitoring of state of charge (SOC) of the battery management system (BMS), and black start operation. The system is in operation...... values in the system exceed or fall below the predetermine limits, the SCADA system can pop up the alarm screen, give an alert and send a text message or call an specified person via an SMS module. The host not only can monitor the operation status of the system, but also give orders to control...

  14. What SCADA systems can offer to optimize field operations

    International Nuclear Information System (INIS)

    McLean, D.J.

    1997-01-01

    A new technology developed by Kenomic Controls Ltd. of Calgary was designed to solve some of the problems associated with producing gas wells with high gas to liquids ratios. The rationale and the system architecture of the SCADA (Supervisory Control and Data Acquisition) system were described. The most common application of SCADA is the Electronic Flow Measurement (EFM) installation using a solar or thermo-electric generator as a power source for the local electronics. Benefits that the SCADA system can provide to producing fields such as increased revenue, decreased operating costs, decreased fixed capital and working capital requirements, the planning and implementation strategies for SCADA were outlined. A case history of a gas well production optimization system in the Pierceland area of northwest Saskatchewan was provided as an illustrative example. 9 figs

  15. Handbook of SCADA/control systems security

    CERN Document Server

    Radvanovsky, Robert

    2013-01-01

    The availability and security of many services we rely upon-including water treatment, electricity, healthcare, transportation, and financial transactions-are routinely put at risk by cyber threats. The Handbook of SCADA/Control Systems Security is a fundamental outline of security concepts, methodologies, and relevant information pertaining to the supervisory control and data acquisition (SCADA) systems and technology that quietly operate in the background of critical utility and industrial facilities worldwide. Divided into five sections, the book examines topics comprising functions within

  16. Is the CERN recommended SCADA useable for the ST division?

    CERN Document Server

    Sollander, P; Epting, U

    2001-01-01

    Supervisory Control and Data Acquisition (SCADA) systems are widely used at CERN and in industrial control environments. In order to limit the costs of purchase, maintenance and support, a recommendation for one SCADA system is in preparation by the SCADA working group. This SCADA system should be used for all CERN in-house developed applications as they exist today e.g. in the Technical Control Room (TCR). This presentation will show the actual environment for the control and monitoring of the technical infrastructure at CERN and the needs for the future LHC infrastructure monitoring. The presentation will cover the control activities of all ST groups represented in the ST Control System WG. A possible solution for the integration of the technical infrastructure data into a SCADA system and a solution for the data exchange with the accelerators and the experiments will be presented. This includes a short term planning for the evaluation period as well as the long-term strategy on how to implement the chosen ...

  17. Assessing and Augmenting SCADA Cyber Security-A Survey of Techniques

    OpenAIRE

    Patel, S; Nazir, S; Patel, D

    2017-01-01

    SCADA systems monitor and control critical infrastructures of national importance such as power generation and distribution, water supply, transportation networks, and manufacturing facilities. The pervasiveness, miniaturisations and declining costs of internet connectivity have transformed these systems from strictly isolated to highly interconnected networks. The connectivity provides immense benefits such as reliability, scalability and remote connectivity, but at the same time exposes an ...

  18. Pipeline, utilities to spend $127 million on scada systems

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Spending for new or upgraded supervisory control and data acquisition (scada) systems and for additional remote-terminal units (RTUs) by North American pipelines and utilities will exceed $165 million through February 1996. New and updated scada systems will total 122 at a cost of more than $127 million; 143 RTU add-on projects will cost more than $38 million. Pipelines and combined utilities/pipelines will spend $89.5 million for 58 scada-system projects and $30.2 million for RTU add-on projects. Scada systems are computerized hardware and software systems that perform monitoring and control functions. In gas utilities, these systems perform functions normally associated with gas transmission and distribution as well as production-plant process control. In gas and oil pipelines, the systems perform these functions as well as such specialized functions as batch tracking, leak detection, and gas load flow

  19. Enhancing the Safety, Security and Resilience of ICT and Scada Systems Using Action Research

    Science.gov (United States)

    Johnsen, Stig; Skramstad, Torbjorn; Hagen, Janne

    This paper discusses the results of a questionnaire-based survey used to assess the safety, security and resilience of information and communications technology (ICT) and supervisory control and data acquisition (SCADA) systems used in the Norwegian oil and gas industry. The survey identifies several challenges, including the involvement of professionals with different backgrounds and expertise, lack of common risk perceptions, inadequate testing and integration of ICT and SCADA systems, poor information sharing related to undesirable incidents and lack of resilience in the design of technical systems. Action research is proposed as a process for addressing these challenges in a systematic manner and helping enhance the safety, security and resilience of ICT and SCADA systems used in oil and gas operations.

  20. A Log Mining Approach for Process Monitoring in SCADA

    NARCIS (Netherlands)

    Hadziosmanovic, D.; Bolzoni, D.; Hartel, Pieter H.

    2012-01-01

    SCADA (Supervisory Control and Data Acquisition) systems are used for controlling and monitoring industrial processes. We propose a methodology to systematically identify potential process-related threats in SCADA. Process-related threats take place when an attacker gains user access rights and

  1. A Log Mining Approach for Process Monitoring in SCADA

    NARCIS (Netherlands)

    Hadziosmanovic, D.; Bolzoni, D.; Hartel, Pieter H.

    2010-01-01

    SCADA (Supervisory Control and Data Acquisition) systems are used for controlling and monitoring industrial processes. We propose a methodology to systematically identify potential process-related threats in SCADA. Process-related threats take place when an attacker gains user access rights and

  2. The benefits of SCADA integrated pipeline leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Pichler, Ruprecht M.J. [Pichler Engineering GmbH, Munich (Germany)

    2003-07-01

    Software based leak detection and locating for pipelines based upon evaluation of hydraulic parameters is a widely used approach to online pipeline integrity monitoring. Typically, these software packages are installed in a stand-alone configuration with a narrow bandwidth interface to the pipeline SCADA system. However, the performance characteristics of the SCADA system and interface do have a substantial impact on the performance of the leak detection system. By a tight integration of leak detection software into the SCADA system, a source of false alarms typically experienced with leak detection systems can be eliminated, the overall performance of the leak detection system can be improved, and the project costs can be reduced. (author)

  3. Susceptibility of SCADA systems and the energy sector

    Science.gov (United States)

    Goike, Lindsay

    The research in this paper focused on analyzing SCADA systems in the energy sector for susceptibility to cyber attacks, in furtherance of providing suggestions to mitigate current and future cyber attacks. The research will be addressing the questions: how are SCADA systems susceptible to cyber attacks, and what are the suggested ways to mitigate both current and future cyber attacks. The five main categories of security vulnerabilities facing current SCADA systems were found to be: connectivity to the Internet, failure to plan, interdependency of sectors, numerous different types of threats, and outdated software. Some of the recommendations mentioned to mitigate current and future risks were: virtual private networks, risk assessments, increased physical security, updating of software, and firewalls.

  4. SCADA AND SECURITY DISPATCHES ACCORDING TO PRESENT LEGISLATION IN ROMANIA

    Directory of Open Access Journals (Sweden)

    Cristian Silviu BANACU

    2014-11-01

    Full Text Available SCADA is an old term, older than twenty years, used for defining systems that acquires data from industrial networks and / or critical infrastructure networks and process them for operational and security purposes. Its importance is growing simultaneously with the development of technology’s interference in our lives (social life, economical life, etc.. Although they are not defined as SCADA systems, Security dispatches (and their structure have a lot of similarities with the general architecture of SCADA systems. Taking into consideration the security dispatches, as they are accepted by the actual Romanian law, we will draw a parallel between them and SCADA architecture, identifying the similarities and the differences between them, and also the points where some changes could be made.

  5. What's under the hood? Improving SCADA security with process awareness

    OpenAIRE

    Chromik, Justyna Joanna; Remke, Anne Katharina Ingrid; Haverkort, Boudewijn R.H.M.

    2016-01-01

    SCADA networks are an essential part of monitoring and controlling physical infrastructures, such as the power grid. Recent news item show that tampering with the data exchanged in a SCADA network occurs and has severe consequences. A possible way of improving the security of SCADA networks is to use intrusion detection systems. By monitoring and analysing the traffic, it is possible to detect whether information has a legitimate source or was tampered with. However, in many cases the knowled...

  6. Predicting Faults in Wind Turbines Using SCADA Data

    DEFF Research Database (Denmark)

    Borchersen, Anders Bech; Larsen, Jesper Abildgaard; Stoustrup, Jakob

    2013-01-01

    The cost of operation and maintenance of wind turbines is a significant part of the overall cost of wind turbines. To reduce this cost a method for enabling early fault detection is proposed and tested in this paper. The method is taking advantage of the fact that wind turbines in wind farms...... and tested on historical Supervisory Control And Data Acquisition (SCADA) data from nine operational turbines over a testing period of nine months. The performance of the fault detection is found to be acceptable based on the testing period. During the testing period several gear related services were...

  7. Resilient Control and Intrusion Detection for SCADA Systems

    Science.gov (United States)

    2014-05-01

    Lowe. The myths and facts behind cyber security risks for industrial control systems . VDE Congress, 2004. [45] I. S. C37.1-1994. Ieee standard...Resilient Control and Intrusion Detection for SCADA Systems Bonnie Xia Zhu Electrical Engineering and Computer Sciences University of California at...3. DATES COVERED 00-00-2014 to 00-00-2014 4. TITLE AND SUBTITLE Resilient Control and Intrusion Detection for SCADA Systems 5a. CONTRACT

  8. A Parameter Selection Method for Wind Turbine Health Management through SCADA Data

    Directory of Open Access Journals (Sweden)

    Mian Du

    2017-02-01

    Full Text Available Wind turbine anomaly or failure detection using machine learning techniques through supervisory control and data acquisition (SCADA system is drawing wide attention from academic and industry While parameter selection is important for modelling a wind turbine’s condition, only a few papers have been published focusing on this issue and in those papers interconnections among sub-components in a wind turbine are used to address this problem. However, merely the interconnections for decision making sometimes is too general to provide a parameter list considering the differences of each SCADA dataset. In this paper, a method is proposed to provide more detailed suggestions on parameter selection based on mutual information. First, the copula is proven to be capable of simplifying the estimation of mutual information. Then an empirical copulabased mutual information estimation method (ECMI is introduced for application. After that, a real SCADA dataset is adopted to test the method, and the results show the effectiveness of the ECMI in providing parameter selection suggestions when physical knowledge is not accurate enough.

  9. Application of Functional Analysis on a SCADA System of a Thermal Power Plant

    Directory of Open Access Journals (Sweden)

    LAKHOUA, M. N.

    2009-06-01

    Full Text Available The aim of this paper is to present firstly the functionality of a supervisory system for complex processes, and secondly to present the concepts of SCADA (supervisory control and data acquisition systems. A functional analysis technique SADT (Structured Analysis and Design Technique has been applied on an example of a SCADA system of a thermal power plant. This technique allows a functional description of a SCADA system. The paper briefly discusses the functions of a SCADA system and some advantages of the application of functional analysis for the design of a human centered supervisory system. Then the basic principles of the SADT technique applied on the SCADA system are presented. Finally, the different results obtained from the SADT technique are discussed.

  10. Review of Supervisory Control and Data Acquisition (SCADA) Systems

    Energy Technology Data Exchange (ETDEWEB)

    Reva Nickelson; Briam Johnson; Ken Barnes

    2004-01-01

    A review using open source information was performed to obtain data related to Supervisory Control and Data Acquisition (SCADA) systems used to supervise and control domestic electric power generation, transmission, and distribution. This report provides the technical details for the types of systems used, system disposal, cyber and physical security measures, network connections, and a gap analysis of SCADA security holes.

  11. Analysis of a SCADA System Anomaly Detection Model Based on Information Entropy

    Science.gov (United States)

    2014-03-27

    Gerard, 2005:3) The NTSB report lists alarm management as one of the top five areas for improvement in pipeline SCADA systems (Gerard, 2005:1...Zhang, Qin, Wang, and Liang for leak detection in a SCADA -run pipeline system. A concept derived from information theory improved leak detection...System for West Products Pipeline . Journal of Loss Prevention in the Process Industries, 22(6), 981-989. Zhu, B., & Sastry, S. (2010). SCADA

  12. Production Facility SCADA Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Holloway, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Baily, Scott A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wheat, Robert Mitchell Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-03-23

    The following report covers FY 14 activities to develop supervisory control and data acquisition (SCADA) system for the Northstar Moly99 production facility. The goal of this effort is to provide Northstar with a baseline system design.

  13. Anomaly-based intrusion detection for SCADA systems

    International Nuclear Information System (INIS)

    Yang, D.; Usynin, A.; Hines, J. W.

    2006-01-01

    Most critical infrastructure such as chemical processing plants, electrical generation and distribution networks, and gas distribution is monitored and controlled by Supervisory Control and Data Acquisition Systems (SCADA. These systems have been the focus of increased security and there are concerns that they could be the target of international terrorists. With the constantly growing number of internet related computer attacks, there is evidence that our critical infrastructure may also be vulnerable. Researchers estimate that malicious online actions may cause $75 billion at 2007. One of the interesting countermeasures for enhancing information system security is called intrusion detection. This paper will briefly discuss the history of research in intrusion detection techniques and introduce the two basic detection approaches: signature detection and anomaly detection. Finally, it presents the application of techniques developed for monitoring critical process systems, such as nuclear power plants, to anomaly intrusion detection. The method uses an auto-associative kernel regression (AAKR) model coupled with the statistical probability ratio test (SPRT) and applied to a simulated SCADA system. The results show that these methods can be generally used to detect a variety of common attacks. (authors)

  14. Cybersecurity for industrial control systems SCADA, DCS, PLC, HMI, and SIS

    CERN Document Server

    Macaulay, Tyson

    2011-01-01

    SCADA - Supervisory Control and Data Acquisition - Systems don't necessarily mesh well with standard IT security, although combined the two can create deepened levels of protection. This book demonstrates how to develop a SCADA cyber security program and how to work with internal and external IT resources in order to implement it. The technical level of this text ensures that it does not provide a detailed 'cookbook' that can be used to attack SCADA systems, but the text still provides sufficient technical detail to address areas of concern.

  15. A SCADA System for Energy Management in Intelligent Buildings

    OpenAIRE

    Figueiredo, Joao; Sá da Costa, Jose

    2012-01-01

    This paper develops an energy management platform for intelligent buildings using a SCADA system (Supervisory Control And Data Acquisition). This SCADA system integrates different types of information coming from the several technologies present in modern buildings (control of ventilation, temperature, illumination, etc.). The developed control strategy implements an hierarchical cascade controller where inner loops are performed by local PLCs (Programmable Logic Controller), and the outer...

  16. Intrusion Detection in SCADA Networks

    NARCIS (Netherlands)

    Barbosa, R.R.R.; Pras, Aiko; Stiller, Burckhard; De Turck, Filip

    Supervisory Control and Data Acquisition (SCADA) sys- tems are a critical part of large industrial facilities, such as water dis- tribution infrastructures. With the goal of reducing costs and increas- ing efficiency, these systems are becoming increasingly interconnected. However, this has also

  17. Software design practice using two SCADA software packages

    DEFF Research Database (Denmark)

    Basse, K.P.; Christensen, Georg Kronborg; Frederiksen, P. K.

    1996-01-01

    Typical software development for manufacturing control is done either by specialists with consideral real-time programming experience or done by the adaptation of standard software packages for manufacturing control. After investigation and test of two commercial software packages: "InTouch" and ......Touch" and "Fix", it is argued, that a more efficient software solution can be achieved by utilising an integrated specification for SCADA and PLC-programming. Experiences gained from process control is planned investigated for descrete parts manufacturing....

  18. Flow whitelisting in SCADA networks

    DEFF Research Database (Denmark)

    Barbosa, Rafael Ramos Regis; Sadre, Ramin; Pras, Aiko

    2013-01-01

    and the Internet. This paper describes an approach for improving the security of SCADA networks using flow whitelisting. A flow whitelist describes legitimate traffic based on four properties of network packets: client address, server address, server-side port and transport protocol. The proposed approach...

  19. Towards a Cyber Defense Framework for SCADA Systems Based on Power Consumption Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Jimenez, Jarilyn M [ORNL; Chen, Qian [Savannah State University; Nichols, Jeff A. {Cyber Sciences} [ORNL; Calhoun, Chelsea [Savannah State University; Sykes, Summer [Savannah State University

    2017-01-01

    Supervisory control and data acquisition (SCADA) is an industrial automation system that remotely monitor, and control critical infrastructures. SCADA systems are major targets for espionage and sabotage attackers. According to the 2015 Dell security annual threat report, the number of cyber-attacks against SCADA systems has doubled in the past year. Cyber-attacks (i.e., buffer overflow, rootkits and code injection) could cause serious financial losses and physical infrastructure damages. Moreover, some specific cyber-attacks against SCADA systems could become a threat to human life. Current commercial off-the-shelf security solutions are insufficient in protecting SCADA systems against sophisticated cyber-attacks. In 2014 a report by Mandiant stated that only 69% of organizations learned about their breaches from third entities, meaning that these companies lack of their own detection system. Furthermore, these breaches are not detected in real-time or fast enough to prevent further damages. The average time between compromise and detection (for those intrusions that were detected) was 205 days. To address this challenge, we propose an Intrusion Detection System (IDS) that detects SCADA-specific cyber-attacks by analyzing the power consumption of a SCADA device. Specifically, to validate the proposed approach, we chose to monitor in real-time the power usage of a a Programmable Logic Controller (PLC). To this end, we configured the hardware of the tetsbed by installing the required sensors to monitor and collect its power consumption. After that two SCADA-specific cyber-attacks were simulated and TracerDAQ Pro was used to collect the power consumption of the PLC under normal and anomalous scenarios. Results showed that is possible to distinguish between the regular power usage of the PLC and when the PLC was under specific cyber-attacks.

  20. Evaluation of Anomaly Detection Techniques for SCADA Communication Resilience

    OpenAIRE

    Shirazi, Syed Noor Ul Hassan; Gouglidis, Antonios; Syeda, Kanza Noor; Simpson, Steven; Mauthe, Andreas Ulrich; Stephanakis, Ioannis M.; Hutchison, David

    2016-01-01

    Attacks on critical infrastructures’ Supervisory Control and Data Acquisition (SCADA) systems are beginning to increase. They are often initiated by highly skilled attackers, who are capable of deploying sophisticated attacks to exfiltrate data or even to cause physical damage. In this paper, we rehearse the rationale for protecting against cyber attacks and evaluate a set of Anomaly Detection (AD) techniques in detecting attacks by analysing traffic captured in a SCADA network. For this purp...

  1. Attacks and intrusion detection in wireless sensor networks of industrial SCADA systems

    Science.gov (United States)

    Kamaev, V. A.; Finogeev, A. G.; Finogeev, A. A.; Parygin, D. S.

    2017-01-01

    The effectiveness of automated process control systems (APCS) and supervisory control and data acquisition systems (SCADA) information security depends on the applied protection technologies of transport environment data transmission components. This article investigates the problems of detecting attacks in wireless sensor networks (WSN) of SCADA systems. As a result of analytical studies, the authors developed the detailed classification of external attacks and intrusion detection in sensor networks and brought a detailed description of attacking impacts on components of SCADA systems in accordance with the selected directions of attacks.

  2. Development of a generic wind farm SCADA system

    Energy Technology Data Exchange (ETDEWEB)

    Smith, G.

    2001-07-01

    The aim of the project is to develop a 'Generic Wind Farm Supervisory Control and Data Acquisition (SCADA) System' for the wind energy industry. A SCADA is a computer-based system that allows local and remote control of basic wind turbine functions and collects data from the wind farm that can be used to analyse and report on the operational performance. As wind farm size, complexity and remoteness of location increase an industry standard SCADA is vitally important to allow effective operation, monitoring, control and reporting. Turbine manufacturers offer a number of existing systems but these do not always fully meet the needs of wind farm operators and owners. Operators and owners who are involved with more than one turbine supplier end up with a number of incompatible systems. This causes operational difficulties and makes it hard to compared performance data from different turbines. This project aims to address these issues and develop a system that will communicate with all turbine types and calculate and store performance data in a consistent way. (Author)

  3. Design of virtual SCADA simulation system for pressurized water reactor

    International Nuclear Information System (INIS)

    Wijaksono, Umar; Abdullah, Ade Gafar; Hakim, Dadang Lukman

    2016-01-01

    The Virtual SCADA system is a software-based Human-Machine Interface that can visualize the process of a plant. This paper described the results of the virtual SCADA system design that aims to recognize the principle of the Nuclear Power Plant type Pressurized Water Reactor. This simulation uses technical data of the Nuclear Power Plant Unit Olkiluoto 3 in Finland. This device was developed using Wonderware Intouch, which is equipped with manual books for each component, animation links, alarm systems, real time and historical trending, and security system. The results showed that in general this device can demonstrate clearly the principles of energy flow and energy conversion processes in Pressurized Water Reactors. This virtual SCADA simulation system can be used as instructional media to recognize the principle of Pressurized Water Reactor

  4. Design of virtual SCADA simulation system for pressurized water reactor

    Energy Technology Data Exchange (ETDEWEB)

    Wijaksono, Umar, E-mail: umar.wijaksono@student.upi.edu; Abdullah, Ade Gafar; Hakim, Dadang Lukman [Electrical Power System Research Group, Department of Electrical Engineering Education, Jl. Dr. Setiabudi No. 207 Bandung, Indonesia 40154 (Indonesia)

    2016-02-08

    The Virtual SCADA system is a software-based Human-Machine Interface that can visualize the process of a plant. This paper described the results of the virtual SCADA system design that aims to recognize the principle of the Nuclear Power Plant type Pressurized Water Reactor. This simulation uses technical data of the Nuclear Power Plant Unit Olkiluoto 3 in Finland. This device was developed using Wonderware Intouch, which is equipped with manual books for each component, animation links, alarm systems, real time and historical trending, and security system. The results showed that in general this device can demonstrate clearly the principles of energy flow and energy conversion processes in Pressurized Water Reactors. This virtual SCADA simulation system can be used as instructional media to recognize the principle of Pressurized Water Reactor.

  5. A new cyber security risk evaluation method for oil and gas SCADA based on factor state space

    International Nuclear Information System (INIS)

    Yang, Li; Cao, Xiedong; Li, Jie

    2016-01-01

    Based on comprehensive analysis of the structure and the potential safety problem of oil and gas SCADA(Supervisor control and data acquisition) network, aiming at the shortcomings of traditional evaluation methods, combining factor state space and fuzzy comprehensive evaluation method, a new network security risk evaluation method of oil and gas SCADA is proposed. First of all, formal description of factor state space and its complete mathematical definition were presented; secondly, factor fuzzy evaluation steps were discussed; then, using analytic hierarchy method, evaluation index system for oil and gas SCADA system was established, the index weights of all factors were determined by two-two comparisons; structure design of three layers in reasoning machine was completed. Experiments and tests show that the proposed method is accurate, reliable and practical. Research results provide the template and the new method for the other industries.

  6. Analysis of Anholt offshore wind farm SCADA measurements

    DEFF Research Database (Denmark)

    Hansen, Kurt Schaldemose; Volker, Patrick; Pena Diaz, Alfredo

    SCADA measurements from the Danish Anholt offshore wind farm (ANH) for a period of 2½ years have been qualified. ANH covers 12 km × 22 km and is located between Djursland and the island Anholt in Kattegat, Denmark. This qualification encompasses identification of curtailment and idling periods......, start/stop events and a power curve control for each wind turbine in the wind farm. Data also include wind speed measurements from a nearby WindCube lidar and simulations from the WRF model for the same period as the SCADA. An equivalent wind speed (wsi) is derived from the combined power and pitch...

  7. Perancangan Sistem Pemantauan Pengendali Suhu pada Stirred Tank Heater menggunakan Supervisory Control and Data Acquisition (SCADA

    Directory of Open Access Journals (Sweden)

    Ike Bayusari

    2013-04-01

    Full Text Available This paper discusses design of a suhue control monitoring system in stirred tank heater system that has an important function in industrial processes. Monitoring of suhue control system in stirred tank heater is designed using Supervisory Control and Data Acquisition (SCADA that control function of industrial processes. While the actuator to be controlled is the position of burner openings, so that the heat can be adjusted to meet a predetermined set-point. The suhue controller that is also used as a Remote Terminal Unit (RTU is Programmable Logic Controller (PLC. The testing result showed on SCADA system was quite good, where the average percentage of deviation for testing of set-point data was 0.76687%, and the percentage of deviation for testing of suhue data was 0.082%.

  8. MultiController: the PLC-SCADA object for advanced regulation

    CERN Document Server

    Ortola, J

    2007-01-01

    Nowadays, industrial solutions with PLCs (Programmable Logic Controllers) have basic control loop features. The SCADA (Supervisory Control And Data Acquisition) system is a key point of the process control system due to an efficient HMI (Human Machine Interfaces) that provides an open method of tuning and leading possibilities. As a consequence, advanced control algorithms have to be developed and implemented for those PLC-SCADA solutions in order to provide perspectives in solving complex and critical regulation problems. The MultiController is an object integrated for a large scale project at CERN (the European Organization for Nuclear Research) named LHC-GCS (Large Hadron Collider - Gas Control System). It is developed for a Framework called CERN-UNICOS based on PLC-SCADA facilities. The MultiController object offers various advanced control loop strategies. It gives to the user advanced control algorithms like PID, Smith Predictor, PFC, GPC and RST. It is implemented as a monolithic entity (in PLC and SCA...

  9. Creating a European SCADA Security Testbed

    NARCIS (Netherlands)

    Christiansson, H.; Luiijf, H.A.M.

    2008-01-01

    Supervisory control and data acquisition (SCADA) systems are commonly used to monitor and control critical infrastructure assets. However, over the past two decades, they have evolved from closed, proprietary systems to open networks comprising commodity platforms running common operating systems

  10. SISTEMA SCADA PARA EL PROCESO DE PASTEURIZACION DE JUGOS

    Directory of Open Access Journals (Sweden)

    Juan de Dios Contreras Cáceres

    2014-06-01

    Full Text Available La finalidad de este artículo es dar a conocer el proyecto desarrollado para diseñar e implementar un sistema SCADA (Supervisory Control And Data Adquisition aplicado al proceso de pasteurización de jugos. Se siguieron las etapas de diseño, partiendo de la elaboración del esquemático Layout, la programación del PLC, los drivers de comunicación y el diseño del software SCADA para una planta de jugos.

  11. CDP - Adaptive Supervisory Control and Data Acquisition (SCADA) Technology for Infrastructure Protection

    Energy Technology Data Exchange (ETDEWEB)

    Marco Carvalho; Richard Ford

    2012-05-14

    Supervisory Control and Data Acquisition (SCADA) Systems are a type of Industrial Control System characterized by the centralized (or hierarchical) monitoring and control of geographically dispersed assets. SCADA systems combine acquisition and network components to provide data gathering, transmission, and visualization for centralized monitoring and control. However these integrated capabilities, especially when built over legacy systems and protocols, generally result in vulnerabilities that can be exploited by attackers, with potentially disastrous consequences. Our research project proposal was to investigate new approaches for secure and survivable SCADA systems. In particular, we were interested in the resilience and adaptability of large-scale mission-critical monitoring and control infrastructures. Our research proposal was divided in two main tasks. The first task was centered on the design and investigation of algorithms for survivable SCADA systems and a prototype framework demonstration. The second task was centered on the characterization and demonstration of the proposed approach in illustrative scenarios (simulated or emulated).

  12. Automated turn pike using PLC and SCADA

    Science.gov (United States)

    Silpa Sreedhar, P.; Aiswarya, P.; Kathirvelan, J.

    2017-11-01

    We propose a smart turnpike based on Programmable Logic Controller (PLC) and Supervisory Control and Data Acquisition Systems (SCADA) in this paper. In this work, the basic idea is to measure the weight of the vehicles and classify them according to its weight to the respective lanes. It is difficult for the turnpike people to monitor the whole process all the time. So, this PLC based diversion system can be implemented in turnpikes to reduce the difficulties. This method will work based on weight sensors (piezo-resistive) whose output will be fed to a PLC, which will control the vehicle diversion. Using SCADA software, the whole process can be monitored from a remote area. The algorithm developed in this successfully installed in real time system.

  13. New Security Development and Trends to Secure the SCADA Sensors Automated Transmission during Critical Sessions

    Directory of Open Access Journals (Sweden)

    Aamir Shahzad

    2015-10-01

    Full Text Available Modern technology enhancements have been used worldwide to fulfill the requirements of the industrial sector, especially in supervisory control and data acquisition (SCADA systems as a part of industrial control systems (ICS. SCADA systems have gained popularity in industrial automations due to technology enhancements and connectivity with modern computer networks and/or protocols. The procurement of new technologies has made SCADA systems important and helpful to processing in oil lines, water treatment plants, and electricity generation and control stations. On the other hand, these systems have vulnerabilities like other traditional computer networks (or systems, especially when interconnected with open platforms. Many international organizations and researchers have proposed and deployed solutions for SCADA security enhancement, but most of these have been based on node-to-node security, without emphasizing critical sessions that are linked directly with industrial processing and automation. This study concerns SCADA security measures related to critical processing with specified sessions of automated polling, analyzing cryptography mechanisms and deploying the appropriate explicit inclusive security solution in a distributed network protocol version 3 (DNP3 stack, as part of a SCADA system. The bytes flow through the DNP3 stack with security computational bytes within specified critical intervals defined for polling. We took critical processing knowledge into account when designing a SCADA/DNP3 testbed and deploying a cryptography solution that did not affect communications.

  14. Smart Device Profiling for Smart SCADA

    NARCIS (Netherlands)

    Hadziosmanovic, D.; Bolzoni, D.; Hartel, Pieter H.

    2011-01-01

    SCADA (Supervisory Control and Data Acquisition) systems are computer systems used for monitoring and controlling industrial processes such as power plants and power grid systems, water, gas and oil distribution systems, production systems for food, cars and other products. We propose a new approach

  15. Smart Device Profiling for Smart SCADA

    NARCIS (Netherlands)

    Hadziosmanovic, D.; Bolzoni, D.; Hartel, Pieter H.

    SCADA (Supervisory Control and Data Acquisition) systems are computer systems used for monitoring and controlling industrial processes such as power plants and power grid systems, water, gas and oil distribution systems, production systems for food, cars and other products. We propose a new approach

  16. Supervisory Control and Data Acquisition (SCADA) Security Awareness In a Resource Constrained Learning Environment

    Science.gov (United States)

    2014-06-16

    SCADA systems are connected in some manner to the Global Information Grid ( GIG ), the requirement to educate future computer scientists, software...improves retention and understanding of the learning outcomes [6]. Due to the impact these vulnerabilities can have on the economy , military, and...implications such as what impact a persistent blackout would have on local and national economies . Once a firm understanding of the strategic impacts

  17. Effectiveness of SCADA Systems in Control of Green Sands Properties

    Directory of Open Access Journals (Sweden)

    Ignaszak Z.

    2016-03-01

    Full Text Available The paper undertakes an important topic of evaluation of effectiveness of SCADA (Supervisory Control and Data Acquisition systems, used for monitoring and control of selected processing parameters of classic green sands used in foundry. Main focus was put on process studies of properties of so-called 1st generation molding sands in the respect of their preparation process. Possible methods of control of this processing are presented, with consideration of application of fresh raw materials, return sand (regenerate and water. The studies conducted in one of European foundries were aimed at pointing out how much application of new, automated plant of sand processing incorporating the SCADA systems allows stabilizing results of measurement of selected sand parameters after its mixing. The studies concerned two comparative periods of time, before an implementation of the automated devices for green sands processing (ASMS - Automatic Sand Measurement System and MCM – Main Control Module and after the implementation. Results of measurement of selected sand properties after implementation of the ASMS were also evaluated and compared with testing studies conducted periodically in laboratory.

  18. Multiple Flow Loop SCADA System Implemented on the Production Prototype Loop

    Energy Technology Data Exchange (ETDEWEB)

    Baily, Scott A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wheat, Robert Mitchell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-16

    The following report covers FY 15 activities to develop supervisory control and data acquisition (SCADA) system for the Northstar Moly99 production prototype gas flow loop. The goal of this effort is to expand the existing system to include a second flow loop with a larger production-sized blower. Besides testing the larger blower, this system will demonstrate the scalability of our solution to multiple flow loops.

  19. A First Look into SCADA Network Traffic

    NARCIS (Netherlands)

    Barbosa, R.R.R.; Sadre, R.; Pras, Aiko

    Supervisory Control and Data Acquisition (SCADA) networks are commonly deployed to aid the operation of critical infrastructures, such as water distribution facilities. These networks provide automated processes that ensure the correct functioning of these infrastructures, in a operation much

  20. Design and Implementation of IoT Cloud Moveable SCADA Supported by GSM for Industrial Applications

    Directory of Open Access Journals (Sweden)

    Mahmoud Shaker Nasr

    2017-05-01

    Full Text Available The world at the beginning of a new era of innovation and development with the rise of the industrial Internet or Internet of Things, IoT. It takes the space through the convergence of the global industrial system with the power of advanced computing, analytics, and low cost sensor devices and innovation of communication allowed by the Internet. One of the most important developments is IoT SCADA systems, which are considered as infrastructure of society because of their potential enormous in several industrial applications. This paper presents the design of a new generation of SCADA, named moveable SCADA , based on IoT cloud, and supported by GSM for more flexibility and reliability. The system is applied to industrial application that consists of three-control processes which are temperature, liquid level and motor processes. The three control processes data acquisition and controllers are implemented using embedded microcontroller system while a gateway is used to transfer the data proceed in field supervisor at first as well as main supervisor and monitoring engineer through IoT cloud. The system supported by GSM unit to support the system in case of internet failure. Also a camera is added to the system in order to monitor any location, any location (determined by any of the authorities in the field where the camera is mounted. The proposed SCADA is implemented practically and tested for many cases; the presented obtained results demonstrate that the system operation is very fair and meet the required targets.

  1. A review of cyber security risk assessment methods for SCADA systems

    OpenAIRE

    Cherdantseva, Yulia; Burnap, Peter; Blyth, Andrew; Eden, Peter; Jones, Kevin; Soulsby, Hugh; Stoddart, Kristan

    2016-01-01

    This paper reviews the state of the art in cyber security risk assessment of Supervisory Control and Data Acquisition (SCADA) systems. We select and in-detail examine twenty-four risk assessment methods developed for or applied in the context of a SCADA system. We describe the essence of the methods and then analyse them in terms of aim; application domain; the stages of risk management addressed; key risk management concepts covered; impact measurement; sources of probabilistic data; evaluat...

  2. National SCADA Test Bed Substation Automation Evaluation Report

    Energy Technology Data Exchange (ETDEWEB)

    Kenneth Barnes; Briam Johnson

    2009-10-01

    Increased awareness of the potential for cyber attack has recently resulted in improved cyber security practices associated with the electrical power grid. However, the level of practical understanding and deployment of cyber security practices has not been evenly applied across all business sectors. Much of the focus has been centered on information technology business centers and control rooms. This report explores the current level of substation automation, communication, and cyber security protection deployed in electrical substations throughout existing utilities in the United States. This report documents the evaluation of substation automation implementation and associated vulnerabilities. This evaluation used research conducted by Newton-Evans Research Company for some of its observations and results. The Newton Evans Report aided in the determination of what is the state of substation automation in North American electric utilities. Idaho National Laboratory cyber security experts aided in the determination of what cyber vulnerabilities may pose a threat to electrical substations. This report includes cyber vulnerabilities as well as recommended mitigations. It also describes specific cyber issues found in typical substation automation configurations within the electric utility industry. The evaluation report was performed over a 5-month period starting in October 2008

  3. An engineering study and concept design of the Supervisory Control and Data Acquisition (SCADA) for conventional systems

    International Nuclear Information System (INIS)

    Norman, L.S.

    1993-05-01

    The study objective was to evaluate several conventional equipment SCADA system architectural concepts and to recommend an approach for development. Each of the concepts given consideration had to satisfy the Superconducting Super Collider (SSC) conventional equipment SCADA application requirements and the evaluation process determined which approach represented the best technical and most cost effective solution to the system requirements. Based on the results of the concept evaluation process, a personal computer based approach was recommended for the SSC conventional equipment SCADA application. Block diagrams and budgetary cost estimate for this approach were developed with specific recommendations with respect to the conventional equipment SCADA system architecture and development process

  4. Proposta de arquitetura orientada a recursos para SCADA na Web

    OpenAIRE

    Polônia, Pablo Valério

    2011-01-01

    Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Automação e Sistemas, Florianópolis, 2011 Esta dissertação descreve uma proposta de arquitetura de software para aplicações típicas de Sistemas de Supervisão e Aquisição de Dados (SCADA), utilizando a World Wide Web como plataforma. O objetivo é mostrar como os requisitos característicos de aplicações SCADA podem ser incorporados em uma arquitetura condizente com ...

  5. Cyber security risk assessment for SCADA and DCS networks.

    Science.gov (United States)

    Ralston, P A S; Graham, J H; Hieb, J L

    2007-10-01

    The growing dependence of critical infrastructures and industrial automation on interconnected physical and cyber-based control systems has resulted in a growing and previously unforeseen cyber security threat to supervisory control and data acquisition (SCADA) and distributed control systems (DCSs). It is critical that engineers and managers understand these issues and know how to locate the information they need. This paper provides a broad overview of cyber security and risk assessment for SCADA and DCS, introduces the main industry organizations and government groups working in this area, and gives a comprehensive review of the literature to date. Major concepts related to the risk assessment methods are introduced with references cited for more detail. Included are risk assessment methods such as HHM, IIM, and RFRM which have been applied successfully to SCADA systems with many interdependencies and have highlighted the need for quantifiable metrics. Presented in broad terms is probability risk analysis (PRA) which includes methods such as FTA, ETA, and FEMA. The paper concludes with a general discussion of two recent methods (one based on compromise graphs and one on augmented vulnerability trees) that quantitatively determine the probability of an attack, the impact of the attack, and the reduction in risk associated with a particular countermeasure.

  6. Community energy storage and distribution SCADA improvements

    International Nuclear Information System (INIS)

    Riggins, M.

    2010-01-01

    The mission of American Electric Power (AEP) is to sustain the real time balance of energy supply and demand. Approximately 2.5 percent of energy generated in the United States (USA) is stored as pumped hydro, compressed air, or in batteries and other devices. This power point presentation discussed the use of SCADA for improving community energy storage (CES) and distribution systems. CES is a distributed fleet of small energy units connected to the transformers in order to serve houses or small commercial loads. CES is operated as a fleet offering multi-megawatt (MW) multi-hour storage. The benefits of CES include backup power, flicker mitigation, and renewable integration. Benefits to the electricity grid include power factor correct, ancillary services, and load leveling at the substation level. SCADA is being used to determine when emergency load reductions are required or when emergency inspections on fans, oil pumps or other devices are needed. An outline of AEP's monitoring system installation plan was also included. tabs., figs.

  7. Developments on the SCADA of CERN Accelerators Vacuum

    CERN Document Server

    Antoniotti, F; Boccioli, M; Gomes, P; Pereira, H; Kopylov, L; Mikheev, M; Merker, S

    2014-01-01

    During the first 3 years of LHC operation, the priority for the SCADA (Supervisory Control And Data Acquisition) of vacuum controls was to attend to user requests, and to improve its ergonomics and efficiency: access & presentation of information simplified and normalized; coherent functionalities & menus across all accelerators; automatic scripts instead of fastidious manual actions; enhanced tools for data analysis and for maintenance interventions. Several decades of cumulative developments, based on heterogeneous technologies and architectures, have been asking for a homogenization effort. The first LHC Long Shutdown (LS1) provides the opportunity to further standardize the vacuum controls systems [1], around Siemens-S7 PLCs (Programmable Logic Controllers) and PVSS SCADA. Meanwhile, exchanges with other Groups at CERN and outside Institutes have been promoted: to follow the global update policy for software libraries; to discuss philosophies and development details; and to accomplish common pro...

  8. Integration of Evora-InovGrid Smartmeters in a Consumer’s SCADA System

    OpenAIRE

    Pereira, Rita; Figueiredo, Joao; Martins, Joao; Quadrado, Jose; Melicio, Rui; Mendes, Victor

    2015-01-01

    This paper develops an energy management system with smart meters integration for electricity consumers in a smart grid context. The integration of a distributor owned smart meter from the main Portuguese electricity distributor – EDP - is developed. The smart meter is connected to a common PC, that runs the Matlab Software and communicates to the SCADA system (Supervisory Control And Data Acquisition) using the OPC Protocol. The SCADA system supervises an industrial network of Programmable L...

  9. Difficulties in Modeling SCADA Traffic: A Comparative Analysis

    NARCIS (Netherlands)

    Barbosa, R.R.R.; Sadre, R.; Pras, Aiko

    Modern critical infrastructures, such as water distribution and power generation, are large facilities that are distributed over large geographical areas. Supervisory Control and Data Acquisition (SCADA) networks are deployed to guarantee the correct operation and safety of these infrastructures. In

  10. Evaluating resilience of DNP3-controlled SCADA systems against event buffer flooding

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Guanhua [Los Alamos National Laboratory; Nicol, David M [UNIV OF IL; Jin, Dong [UNIV OF IL

    2010-12-16

    The DNP3 protocol is widely used in SCADA systems (particularly electrical power) as a means of communicating observed sensor state information back to a control center. Typical architectures using DNP3 have a two level hierarchy, where a specialized data aggregator device receives observed state from devices within a local region, and the control center collects the aggregated state from the data aggregator. The DNP3 communication between control center and data aggregator is asynchronous with the DNP3 communication between data aggregator and relays; this leads to the possibility of completely filling a data aggregator's buffer of pending events, when a relay is compromised or spoofed and sends overly many (false) events to the data aggregator. This paper investigates how a real-world SCADA device responds to event buffer flooding. A Discrete-Time Markov Chain (DTMC) model is developed for understanding this. The DTMC model is validated by a Moebius simulation model and data collected on real SCADA testbed.

  11. SCADA Sistemi ile Bir İşletmenin Dış Saha Otomasyonu

    OpenAIRE

    Kılıç, Murat; Özdemir, Şule

    2010-01-01

    Bu çalışmada, PLC (Programmable Logic Controller: Programlanabilir Mantık Denetleyici) ve SCADA (Supervising Control and Data Acquisition: Veri Tabanlı Kontrol ve Gözetleme) sistemleriyle bir MDF (Medium Density Fiberboard) presi dış saha besleme hattının otomasyonu gerçekleştirilmiştir. Tüm sistem SCADA sayesinde bilgisayar ekranından izlenebilmekte ve kontrol edilebilmektedir. MDF presi dış saha besleme hattı tam otomasyon ile çalışmaktadır. Otomasyon sisteminde PLC yazılımı olarak Siemens ...

  12. Towards Periodicity Based Anomaly Detection in SCADA Networks

    NARCIS (Netherlands)

    Barbosa, R.R.R.; Sadre, R.; Pras, Aiko

    Supervisory Control and Data Acquisition (SCADA) networks are commonly deployed to aid the operation of large industrial facilities. The polling mechanism used to retrieve data from field devices causes the data transmission to be highly periodic. In this paper, we propose an approach that exploits

  13. SCADA systems in the industrial automation

    Directory of Open Access Journals (Sweden)

    Esteban Pérez-López

    2015-12-01

    Este tipo de software constituye un avance de gran impacto en la automatización industrial, ya que permite ilustrar gráficamente los procesos productivos en pantalla y crear alarmas y advertencias en tiempo real, para el manejo confiado y pleno del proceso que se desea controlar. Se presentan los ejemplos de dos industrias que han aplicado SCADA con el fin de mejorar sus procesos, obteniendo muy buenos resultados.

  14. PLC SCADA systém pro řízení větrného tunelu

    OpenAIRE

    Trenčan, Tomáš

    2017-01-01

    Předložená bakalářská práce se věnuje programovatelnému automatu (PLC) firmy WAGO a SCADA systémům. Skládá se ze dvou části, z teoretické části a z praktické části. V teoretické části jsou na zakladě poznatků z odborné literatury vymezeny pojmy ohledně SCADA systémů, PLC od firmy WAGO a vývojového prostředí e!COCKPIT firmy WAGO a rešerše volně dostupných SCADA systémů podporujících Modbus TCP. Na základě této rešerše byl vybrán SCADA systém pro vizualizaci dvou demonstračníc úloh v praktické ...

  15. Wind turbine condition monitoring based on SCADA data using normal behavior models

    DEFF Research Database (Denmark)

    Schlechtingen, Meik; Santos, Ilmar; Achiche, Sofiane

    2013-01-01

    This paper proposes a system for wind turbine condition monitoring using Adaptive Neuro-Fuzzy Interference Systems (ANFIS). For this purpose: (1) ANFIS normal behavior models for common Supervisory Control And Data Acquisition (SCADA) data are developed in order to detect abnormal behavior...... the applicability of ANFIS models for monitoring wind turbine SCADA signals. The computational time needed for model training is compared to Neural Network (NN) models showing the strength of ANFIS in training speed. (2) For automation of fault diagnosis Fuzzy Interference Systems (FIS) are used to analyze...

  16. Anomaly Detection in SCADA Systems - A Network Based Approach

    NARCIS (Netherlands)

    Barbosa, R.R.R.

    2014-01-01

    Supervisory Control and Data Acquisition (SCADA) networks are commonly deployed to aid the operation of large industrial facilities, such as water treatment facilities. Historically, these networks were composed by special-purpose embedded devices communicating through proprietary protocols.

  17. Anomaly detection in SCADA systems: a network based approach

    NARCIS (Netherlands)

    Barbosa, R.R.R.

    2014-01-01

    Supervisory Control and Data Acquisition (SCADA) networks are commonly deployed to aid the operation of large industrial facilities, such as water treatment facilities. Historically, these networks were composed by special-purpose embedded devices communicating through proprietary protocols.

  18. Summer Student Work Project Report: SCADA Bridge Tool Development Automatically Capturing Data from SCADA to the Maintenance System

    CERN Document Server

    Alhambra-Moron, Alfonso

    2015-01-01

    The main purpose of this report is to summarize the work project I have been doing at CERN during the last 3 months as a Summer Student. My name is Alfonso Alhambra Morón and the 8th of June 2015 I joined the EN-HE-LM team as a summer student supervised by Damien Lafarge in order to collaborate in the automation of the transfer of meter readings from SCADA1 to Infor EAM2, the computerized maintenance management system at CERN. The main objective of my project was to enable the automatic updates of meters in Infor EAM fetching data from SCADA so as to automatize a process which was done manually before and consumed resources in terms of having to consult the meter physically, import this information to Infor EAM by hand and detecting and correcting the errors that can occur when doing all of this manually. This problem is shared by several other teams at CERN apart from the Lift Maintenance team and for this reason the main target I had when developing my solution was flexibility and scalability so as to make...

  19. Vulnerability assessment of critical infrastructure : activity 2 progress report : information of SCADA systems and other security monitoring systems used in oil and gas pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Gu, G.P. [Natural Resources Canada, Ottawa, ON (Canada). CANMET Materials Technology Laboratory

    2007-12-15

    Many pipelines are located in remote regions and subjected to harsh environmental conditions. Damage to pipelines can have significant economic and environmental impacts. This paper discussed the use of supervisory control and data acquisition (SCADA) systems to monitor and control oil and gas pipeline infrastructure. SCADA systems are a real time, distributed computerized system with an intelligent capability for condition identification and fault diagnosis. SCADA systems can be used to capture thousands of miles of pipeline system process data and distribute it to pipeline operators, whose work stations are networked with the SCADA central host computer. SCADA architectures include monolithic, distributed, and networked systems that can be distributed across wide area networks (WANs). SCADA security strategies must be implemented to ensure corporate network security. Case studies of SCADA systems currently used by oil and gas operators in Alberta were also presented. 15 refs., 1 fig.

  20. Data Mining Learning Models and Algorithms on a Scada System Data Repository

    Directory of Open Access Journals (Sweden)

    Mircea Rîşteiu

    2010-06-01

    Full Text Available This paper presents three data mining techniques applied
    on a SCADA system data repository: Naijve Bayes, k-Nearest Neighbor and Decision Trees. A conclusion that k-Nearest Neighbor is a suitable method to classify the large amount of data considered is made finally according to the mining result and its reasonable explanation. The experiments are built on the training data set and evaluated using the new test set with machine learning tool WEKA.

  1. Supervisory Control and Data Acquisition (SCADA) Systems and Cyber-Security: Best Practices to Secure Critical Infrastructure

    Science.gov (United States)

    Morsey, Christopher

    2017-01-01

    In the critical infrastructure world, many critical infrastructure sectors use a Supervisory Control and Data Acquisition (SCADA) system. The sectors that use SCADA systems are the electric power, nuclear power and water. These systems are used to control, monitor and extract data from the systems that give us all the ability to light our homes…

  2. Design of SCADA water resource management control center by a bi-objective redundancy allocation problem and particle swarm optimization

    International Nuclear Information System (INIS)

    Dolatshahi-Zand, Ali; Khalili-Damghani, Kaveh

    2015-01-01

    SCADA is an essential system to control critical facilities in big cities. SCADA is utilized in several sectors such as water resource management, power plants, electricity distribution centers, traffic control centers, and gas deputy. The failure of SCADA results in crisis. Hence, the design of SCADA system in order to serve a high reliability considering limited budget and other constraints is essential. In this paper, a bi-objective redundancy allocation problem (RAP) is proposed to design Tehran's SCADA water resource management control center. Reliability maximization and cost minimization are concurrently considered. Since the proposed RAP is a non-linear multi-objective mathematical programming so the exact methods cannot efficiently handle it. A multi-objective particle swarm optimization (MOPSO) algorithm is designed to solve it. Several features such as dynamic parameter tuning, efficient constraint handling and Pareto gridding are inserted in proposed MOPSO. The results of proposed MOPSO are compared with an efficient ε-constraint method. Several non-dominated designs of SCADA system are generated using both methods. Comparison metrics based on accuracy and diversity of Pareto front are calculated for both methods. The proposed MOPSO algorithm reports better performance. Finally, in order to choose the practical design, the TOPSIS algorithm is used to prune the Pareto front. - Highlights: • Multi-objective redundancy allocation problem (MORAP) is proposed to design SCADA system. • Multi-objective particle swarm optimization (MOPSO) is proposed to solve MORAP. • Efficient epsilon-constraint method is adapted to solve MORAP. • Non-dominated solutions are generated on Pareto front of MORAP by both methods. • Several multi-objective metrics are calculated to compare the performance of methods

  3. MicroSCADA project documentation database

    OpenAIRE

    Kolam, Karolina

    2014-01-01

    Detta ingenjörsarbete var beställt av ABB Power Systems, Network Management. Syftet med detta ingenjörsarbete var att skapa en databas för dokumentering av information om MicroSCADA projekt. Ett lämpligt verktyg för att skapa rapporter och skriva ny data till databasen skulle också ingå. Före detta ingenjörsarbete sparades all information som skilda textdokument. Med en databas kunde man samla all information på ett ställe för att arkiveras under en längre tid. Det förenklad...

  4. Evaluating Information Assurance Control Effectiveness on an Air Force Supervisory Control and Data Acquisition (SCADA) System

    Science.gov (United States)

    2011-03-01

    Byres, E. J., Lowe, J. (2004). The Myths and facts behind cyber security risks for industrial control systems . Berlin, Germany: VDE 2004 Congress...ACQUISITION (SCADA) SYSTEM THESIS Jason R. Nielsen, Major, USAF AFIT/GCO/ENG/11-10 DEPARTMENT OF THE AIR FORCE AIR UNIVERSITY AIR FORCE...DATA ACQUISITION (SCADA) SYSTEM THESIS Presented to the Faculty Department of Electrical and Computer Engineering Graduate School of

  5. Installation of a Wastewater SCADA Monitoring System at Fort Bragg, NC

    National Research Council Canada - National Science Library

    Mullaney, Joe

    2004-01-01

    .... The Wastewater SCADA Monitoring System was installed to monitor 26 remote sites. A detailed radio study of the area verified the feasibility of using radio equipment to transfer data from these sites...

  6. Rancang Bangun Sistem Scada (Supervisory Control And Data Acquisition pada Instalasi Pengolahan Air Sungai Cihideung Institut Pertanian Bogor

    Directory of Open Access Journals (Sweden)

    Agus Eko Handoko

    2017-08-01

    Full Text Available Abstract SCADA is a combination of telemetry and data acquisition. SCADA proceeding by means of accumulating some information and return back to center controlling, it is also implementing every analysis and necessary control through PID control system as a control parameter to SCADA input data system in this research. In designing PID control system it is needed the arrangement of P, I and D parameter in order to acquire output signal system to particular input system which has adjusted to necessity. The research was implemented on Water Treatment Plant in Bogor Agricultural University at Cihideung's area region. The NTU score as a starting operational data is necessary as a bench mark in PAC dose application which is obtained from the samples of morning and afternoon raw water and dose proportion is 75% for 14kgs PAC mixed with 200 Litre water within 30 NTU as the maximal treatment. 75% dose application can be imposed for 7 hours PAC usage. The result of research indicated that the variety of percentages value in PAC dose application delivered the advantage in operating of clean water processing installation particularly for PAC needed. Design Of SCADA System SCADA indicated the outcome of unit data acquirement on certain period to determine the PAC necessity in operating Water Treatment Plant.

  7. Process Control/SCADA system vendor security awareness and security posture.

    NARCIS (Netherlands)

    Luiijf, H.A.M.; Lüders, S.

    2009-01-01

    A starting point for the adequate security of process control/SCADA systems is the security awareness and security posture by the manufacturers, vendors, system integrators, and service organisations. The results of a short set of questions indicate that major security improvements are required in

  8. An Efficient Approach of Load Shifting by Using SCADA

    Directory of Open Access Journals (Sweden)

    Usman Sohail

    2016-08-01

    Full Text Available The consumption of electric power has increased significantly in the past few years, and its demand is still increasing every day. In this regard, its proper distribution is a significant challenge. This paper includes a method not only to improve the existing power distribution by using SCADA but also to reduce the human errors from the system by making the system automated. As a prototype for this paper, a geographical area was divided in to three regions named as A-Islamabad, B-Rawalpindi and C-Attock. These three regions were used as the Remote Terminal Units RTU’s and were further divided into four sectors based on different types of consumers. One main control unit was set to handle the whole power system which was referred to as the MTU (master terminal unit. MTU was designed in such a way that not only it was capable to show RTU’s readings on Graphical user interface-GUI but also to control them. By establishing such a design, distribution of electric power based on priority was achieved among these regions and thus the load requirements were managed by means of priorities among them. The entire load management task was supervised by an individual who was authorized to control the MTU’s GUI. SCADA system enabled the MTU to regulate the electric power in regions and their sectors. All the RTU’s were connected with the MTU by means of a wireless network based on an Internet Service Provider (ISP. If the system works accordingly, the MTU would be able to access the RTU’s from any part of the world. SCADA provides a platform to manage the overall system with the minimal manpower; hence, the human errors were reduced.

  9. Unavailability of critical SCADA communication links interconnecting a power grid and a Telco network

    International Nuclear Information System (INIS)

    Bobbio, A.; Bonanni, G.; Ciancamerla, E.; Clemente, R.; Iacomini, A.; Minichino, M.; Scarlatti, A.; Terruggia, R.; Zendri, E.

    2010-01-01

    The availability of power supply to power grid customers depends upon the availability of services of supervision, control and data acquisition (SCADA) system, which constitutes the nervous system of a power grid. In turn, SCADA services depend on the availability of the interconnected networks supporting such services. We propose a service oriented stochastic modelling methodology to investigate the availability of large interconnected networks, based on the hierarchical application of different modelling formalisms to different parts of the networks. Interconnected networks are decomposed according to the specific services delivered until the failure and repair mechanisms of the decomposed elementary blocks can be identified. We represent each network by a convenient stochastic modelling formalism, able to capture the main technological issues and to cope with realistic assumptions about failure and recovery mechanisms. This procedure confines the application of the more intensive computational techniques to those subsystems that actually require it. The paper concentrates on an actual failure scenario, occurred in Rome in January 2004 that involved the outage of critical SCADA communication links, interconnecting a power grid and a Telco network.

  10. Unavailability of critical SCADA communication links interconnecting a power grid and a Telco network

    Energy Technology Data Exchange (ETDEWEB)

    Bobbio, A. [Dipartimento di Informatica, Universita del Piemonte Orientale, Viale Michel 11, 15121 Alessandria (Italy); Bonanni, G.; Ciancamerla, E. [ENEA - CRE Casaccia, Via Anguillarese 301, 00060 Roma (Italy); Clemente, R. [Telecom Italia Mobile, Via Isonzo112, 10141 Torino (Italy); Iacomini, A. [ACEA, Pl. Ostiense 2, 00154 Roma (Italy); Minichino, M., E-mail: minichino@casaccia.enea.i [ENEA - CRE Casaccia, Via Anguillarese 301, 00060 Roma (Italy); Scarlatti, A. [ACEA, Pl. Ostiense 2, 00154 Roma (Italy); Terruggia, R. [Dipartimento di Informatica, Universita del Piemonte Orientale, Viale Michel 11, 15121 Alessandria (Italy); Zendri, E. [ACEA, Pl. Ostiense 2, 00154 Roma (Italy)

    2010-12-15

    The availability of power supply to power grid customers depends upon the availability of services of supervision, control and data acquisition (SCADA) system, which constitutes the nervous system of a power grid. In turn, SCADA services depend on the availability of the interconnected networks supporting such services. We propose a service oriented stochastic modelling methodology to investigate the availability of large interconnected networks, based on the hierarchical application of different modelling formalisms to different parts of the networks. Interconnected networks are decomposed according to the specific services delivered until the failure and repair mechanisms of the decomposed elementary blocks can be identified. We represent each network by a convenient stochastic modelling formalism, able to capture the main technological issues and to cope with realistic assumptions about failure and recovery mechanisms. This procedure confines the application of the more intensive computational techniques to those subsystems that actually require it. The paper concentrates on an actual failure scenario, occurred in Rome in January 2004 that involved the outage of critical SCADA communication links, interconnecting a power grid and a Telco network.

  11. Design and Application of SCADA Based Control System for filling process (Inter facing and Monitoring)

    International Nuclear Information System (INIS)

    Aung Naing Myint; Maung Maung Latt; Win Khaing Moe; Theingi

    2008-06-01

    In a small SCADA system, using industrial standard components and simulating real world applications, designs and constructs for thesis to interface between automation devices and software. It programs PIC microcontroller that need the information to write the sequence of process that flowchart like the PIC ladder-logic programs that control the equipment in system, software integrators to be required the information for the configuration screens and hardware installers which need the information to install and connect the equipment. It uses the initiating processor's multiplexer to verify that data or signals are being transmitted out of the parallel port and includes auto-coupler to divide different voltages between circuits and computer. Existing SCADA system are divisible into two groups - cheap and inflexible control, and another one is expensive but flexible control. This thesis attempted by means of using other network for SCADA communications and simple for control, both of which maintain flexibility while reducing cost

  12. Automatic diagnosis method for scada operability

    OpenAIRE

    Syrotkina, O. I.

    2015-01-01

    Пропонується до розгляду методика автоматичної діагностики працездатності SCADA системи в режимі реального часу за зміною інформаційно-діагностичних ознак контрольованих параметрів у процесі проходження потоків даних за структурними одиницями і рівнями ієрархії SCADA. В рамках методики були сформульовані необхідні і достатні критерії виявлення відмови в системі, необхідні і достатні критерії розмежування незалежних і вторинних відмов на підставі логіки функціонування SCADA з ур...

  13. MEDUSA: Mining Events to Detect Undesirable uSer Actions in SCADA

    NARCIS (Netherlands)

    Hadziosmanovic, D.; Bolzoni, D.; Hartel, Pieter H.; Jha, Somesh; Sommer, Robin; Kreibich, Christian

    2010-01-01

    Standard approaches for detecting malicious behaviors, e.g. monitoring network traffic, cannot address process-related threats in SCADA(Supervisory Control And Data Acquisition) systems. These threats take place when an attacker gains user access rights and performs actions which look legitimate,

  14. Assessing and improving SCADA security in the Dutch drinking water sector

    NARCIS (Netherlands)

    Luiijf, H.A.M.; Ali, M.; Zielstra, A.

    2011-01-01

    International studies have shown that information security for process control systems, in particular SCADA, is weak. Many of the critical infrastructure (CI) services critically depend on process control systems. Therefore, any vulnerability in the protection of process control systems in CI may

  15. Assessing and Improving SCADA Security in the Dutch Drinking Water Sector

    NARCIS (Netherlands)

    Luiijf, H.A.M.; Ali, M.; Zielstra, A.

    2009-01-01

    International studies have shown that information security for process control systems, in particular SCADA, is weak. As many critical infrastructure (CI) services depend on process control systems, any vulnerability in the protection of process control systems in CI may result in serious

  16. An Evaluation of Machine Learning Methods to Detect Malicious SCADA Communications

    Energy Technology Data Exchange (ETDEWEB)

    Beaver, Justin M [ORNL; Borges, Raymond Charles [ORNL; Buckner, Mark A [ORNL

    2013-01-01

    Critical infrastructure Supervisory Control and Data Acquisition (SCADA) systems were designed to operate on closed, proprietary networks where a malicious insider posed the greatest threat potential. The centralization of control and the movement towards open systems and standards has improved the efficiency of industrial control, but has also exposed legacy SCADA systems to security threats that they were not designed to mitigate. This work explores the viability of machine learning methods in detecting the new threat scenarios of command and data injection. Similar to network intrusion detection systems in the cyber security domain, the command and control communications in a critical infrastructure setting are monitored, and vetted against examples of benign and malicious command traffic, in order to identify potential attack events. Multiple learning methods are evaluated using a dataset of Remote Terminal Unit communications, which included both normal operations and instances of command and data injection attack scenarios.

  17. Perancangan SCADA Software dengan Wonderware InTouch Recipe Manager dan SQL Access Manager pada Simulator Proses Pencampuran Bahan

    OpenAIRE

    Wicaksono, Handy; Lim, Resmana; Sutanto, William

    2008-01-01

    In Bahasa Indonesia: Banyak industri yang sudah menggunakan sistem automasi dengan menggunakan PLC (Programmable Logic Controller) dan SCADA (Supervisory Control And Data Acquisition). Salah satu software untuk membuat program SCADA adalah Wonderware InTouch. Untuk mengelola data dalam bentuk recipe dan database, Wonderware InTouch mempunyai program-program tambahan yaitu Recipe Manager dan SQL Access Manager. Pada penelitian ini, akan digunakan proses pembuatan kertas sebagai contoh kas...

  18. Designing SCADA application software a practical approach

    CERN Document Server

    McCrady, Stuart G

    2013-01-01

    Automation systems, often referred to as SCADA systems, involve programming at several levels; these systems include computer type field controllers that monitor and control plant equipment such as conveyor systems, pumps, and user workstations that allow the user to monitor and control the equipment through color graphic displays. All of the components of these systems are integrated through a network, such as Ethernet for fast communications. This book provides a practical guide to developing the application software for all aspects of the automation system, from the field controll

  19. Experience of FlexCtrl SCADA usage for accelerator automation

    International Nuclear Information System (INIS)

    Nikiforov, A.S.; Alejnikov, V.V.; Sychev, K.P.; Borina, I.V.; Rukavishnikov, A.A.

    2012-01-01

    Software of particle accelerator control system is described in this paper. Software is based on licensed software (FlexCtrl SCADA, Photon Application Builder, Cogent DataHub) and additionally developed class library. This software is integrated programming environment and according to its functionality serves as visual programming. Properties number of IDE components as well as components number can be increased due to the fact that IDE is characterized by its openness

  20. Information security in SCADA systems in nuclear power plants

    International Nuclear Information System (INIS)

    Satyamurty, S.A.V.

    2013-01-01

    Few decades back most of the I and C systems are Hardwired based. With the developments in digital electronics, micro processors and micro controllers, the I and C systems are becoming more and more Computer based. Though it brought convenience to the designer, comfort to the operator in the form of better GUI, it also brought many challenges in the form of information security. The talk covers the typical I and C design using SCADA systems, the challenges, typical problems faced and the need for information security. The talk illustrates various security measures to be implemented in the design, development and testing stages. These security measures have to be taken both in the development environment and deployment environment. Verification and validation of computer based system is very important. Configuration change management is very essential for smooth running of the plant. The talk illustrates the various measures need to be taken. (author)

  1. Improved production operating efficiencies through automation: Wascana Energy`s SCADA system implementation in southeast Saskatchewan

    Energy Technology Data Exchange (ETDEWEB)

    Knudsen, R; Foord, T; Bartle, A

    1996-12-31

    Supervisory control and data acquisition (SCADA) systems covering Wascana Energy`s whole southeast Saskatchewan operating area were implemented in 1994-95. The benefits of this automation were described. Operations practices were reviewed and a brief description of the system was provided. Main features of the system described included data storage/retrieval, data display, alarm group organization, alarm call out monitoring, dynagraph display, and the Microsoft SQL server computer. Automation was found to significantly change the operator`s traditional role and altered operation practices in general. SCADA systems were found to improve operating efficiencies and production performance significantly, when properly implemented and utilized. 6 refs., 3 figs.

  2. The Research and Improvement of SDT Algorithm for Historical Data in SCADA

    Directory of Open Access Journals (Sweden)

    Xu Xu-Dong

    2017-01-01

    Full Text Available With the rapid development of Internet of things and big data technology, the amount of data collected by SCADA(Supervisory Control And Data Acquisitionsystem is growing exponentially, which the traditional SDT algorithm can not meet the requirements of SCADA system for historical data compression. In this paper, ASDT(Advanced SDT algorithm based on SDT algorithm is proposed and implemented in the Java language, which is based on the deep research of the data compression method, especially the Swing Door Trending. ASDT algorithm through the sine curve fitting data to achieve data compression, compared with the performance of the traditional SDT algorithm, which it can achieve better compression results. The experimental results show that compared with the traditional SDT algorithm, the ASDT algorithm can improve the compression ratio in the case of no significant increase in the compression error, and the compression radio is increased by nearly 50%.

  3. SCADA system with predictive controller applied to irrigation canals

    OpenAIRE

    Figueiredo, João; Botto, Miguel; Rijo, Manuel

    2013-01-01

    This paper applies a model predictive controller (MPC) to an automatic water canal with sensors and actuators controlled by a network (programmable logic controller), and supervised by a SCADA system (supervisory control and a data acquisition). This canal is composed by a set of distributed sub-systems that control the water level in each canal pool, constrained by discharge gates (control variables) and water off-takes (disturbances). All local controllers are available through an industria...

  4. Automatically Identifying and Predicting Unplanned Wind Turbine Stoppages Using SCADA and Alarms System Data: Case Study and Results

    Science.gov (United States)

    Leahy, Kevin; Gallagher, Colm; Bruton, Ken; O'Donovan, Peter; O'Sullivan, Dominic T. J.

    2017-11-01

    Using 10-minute wind turbine SCADA data for fault prediction offers an attractive way of gaining additional prognostic capabilities without needing to invest in extra hardware. To use these data-driven methods effectively, the historical SCADA data must be labelled with the periods when the turbine was in faulty operation as well the sub-system the fault was attributed to. Manually identifying faults using maintenance logs can be effective, but is also highly time consuming and tedious due to the disparate nature of these logs across manufacturers, operators and even individual maintenance events. Turbine alarm systems can help to identify these periods, but the sheer volume of alarms and false positives generated makes analysing them on an individual basis ineffective. In this work, we present a new method for automatically identifying historical stoppages on the turbine using SCADA and alarms data. Each stoppage is associated with either a fault in one of the turbine’s sub-systems, a routine maintenance activity, a grid-related event or a number of other categories. This is then checked against maintenance logs for accuracy and the labelled data fed into a classifier for predicting when these stoppages will occur. Results show that the automated labelling process correctly identifies each type of stoppage, and can be effectively used for SCADA-based prediction of turbine faults.

  5. Analyzing wind turbine directional behavior: SCADA data mining techniques for efficiency and power assessment

    International Nuclear Information System (INIS)

    Castellani, Francesco; Astolfi, Davide; Sdringola, Paolo; Proietti, Stefania; Terzi, Ludovico

    2017-01-01

    Highlights: • The directional behavior of four turbines of an onshore wind farm is investigated. • The positions of the nacelles are discretized to highlight clusterization effects. • The recurrent alignment patterns of the cluster are individuated and analyzed. • The patterns are studied by the point of view of efficiency and power output. • Significative performance deviations arise among the most frequent configurations. - Abstract: SCADA control systems are the keystone for reliable performance optimization of wind farms. Processing into knowledge the amount of information they spread is a challenging task, involving engineering, physics, statistics and computer science skills. This work deals with SCADA data analysis methods for assessing the importance of how wind turbines align in patterns to the wind direction. In particular it deals with the most common collective phenomenon causing clusters of turbines behaving as a whole, rather than as a collection of individuality: wake effects. The approach is based on the discretization of nacelle position measurements and subsequent post-processing through simple statistical methods. A cluster, severely affected by wakes, from an onshore wind farm, is selected as test case. The dominant alignment patterns of the cluster are identified and analyzed by the point of view of power output and efficiency. It is shown that non-trivial alignments with respect to the wind direction arise and important performance deviations occur among the most frequent configurations.

  6. Condition monitoring with wind turbine SCADA data using Neuro-Fuzzy normal behavior models

    DEFF Research Database (Denmark)

    Schlechtingen, Meik; Santos, Ilmar

    2012-01-01

    System (ANFIS) models are employed to learn the normal behavior in a training phase, where the component condition can be considered healthy. In the application phase the trained models are applied to predict the target signals, e.g. temperatures, pressures, currents, power output, etc. The behavior......This paper presents the latest research results of a project that focuses on normal behavior models for condition monitoring of wind turbines and their components, via ordinary Supervisory Control And Data Acquisition (SCADA) data. In this machine learning approach Adaptive Neuro-Fuzzy Interference...... of the prediction error is used as an indicator for normal and abnormal behavior, with respect to the learned behavior. The advantage of this approach is that the prediction error is widely decoupled from the typical fluctuations of the SCADA data caused by the different turbine operational modes. To classify...

  7. From a UNIX to a PC Based SCADA System

    CERN Document Server

    Momal, F

    1999-01-01

    In order to facilitate the development of supervisory applications involved in slow process control (such as cryogenic control), the LHC/IAS Group (Equipment Controls Group) opted, a few years ago, for an industrial SCADA package which runs on UNIXÒ platforms. However, to reduce costs and following market trends, it has been decided to move over to a PC-based package. Several processes relating to the testing of the prototypes of the LHC magnets are already controlled in this way. However, it was still necessary to provide all the services previously available to the users, for example, data archiving in central databases, real-time access through the Web, automatic GSM calls, etc. This paper presents the advantages and drawbacks of a PC-based package versus a Unix-based system. It also lists the criteria used in the market survey to arrive at the final selection, as well as, the overall architecture, highlighting the developments needed to integrate the package into the global computing environment.

  8. An Approach to Vulnerability Assessment for Navy Supervisory Control and Data Acquisition (SCADA) Systems

    National Research Council Canada - National Science Library

    Hart, Dennis

    2004-01-01

    .... SCADA systems are relied upon in a large number of the sectors that make up the critical infrastructure, and their importance was reinforced during the massive power outage that occurred in August 2003...

  9. SCADA System for the Modeling and Optimization of Oil Collecting Pipeline Network: A Case Study of Hassi Messaoud Oilfield

    OpenAIRE

    M. Aouadj; F. Naceri; M. Touileb; D. Sellami; M. Boukhatem

    2015-01-01

    This study aims are data acquisition, control and online modeling of an oil collection pipeline network using a SCADA «Supervisory Control and Data Acquisition» system, allowing the optimization of this network in real time by creating more exact models of onsite facilities. Indeed, fast development of computing systems makes obsolete usage of old systems for which maintenance became more and more expensive and their performances don’t comply any more with modern company operations. SCADA sys...

  10. THE ORGANIZATION OF OPERATIONAL CONTROL AND MANAGEMENT OF ROLL FORMING USING SCADA- SYSTEMS

    Directory of Open Access Journals (Sweden)

    S. A. Teslenko

    2012-01-01

    Full Text Available It is shown that the use Scada-systems for the organization of various systems of automated processes is the most promising method of automation, that gives wide opportunities of control, analysis and management of compiex dynamic, real-time systems.

  11. Study on Parameters Modeling of Wind Turbines Using SCADA Data

    Directory of Open Access Journals (Sweden)

    Yonglong YAN

    2014-08-01

    Full Text Available Taking the advantage of the current massive monitoring data from Supervisory Control and Data Acquisition (SCADA system of wind farm, it is of important significance for anomaly detection, early warning and fault diagnosis to build the data model of state parameters of wind turbines (WTs. The operational conditions and the relationships between the state parameters of wind turbines are complex. It is difficult to establish the model of state parameter accurately, and the modeling method of state parameters of wind turbines considering parameter selection is proposed. Firstly, by analyzing the characteristic of SCADA data, a reasonable range of data and monitoring parameters are chosen. Secondly, neural network algorithm is adapted, and the selection method of input parameters in the model is presented. Generator bearing temperature and cooling air temperature are regarded as target parameters, and the two models are built and input parameters of the models are selected, respectively. Finally, the parameter selection method in this paper and the method using genetic algorithm-partial least square (GA-PLS are analyzed comparatively, and the results show that the proposed methods are correct and effective. Furthermore, the modeling of two parameters illustrate that the method in this paper can applied to other state parameters of wind turbines.

  12. An Architectural Framework for Describing Supervisory Control and Data Acquisition (SCADA) Systems

    Science.gov (United States)

    2004-09-01

    The significant difference between FMS, DP and PA is at the physical layer, which allows all three versions of Profibus to be employed in one SCADA...instrumentation devices, DP devices where speed is important, and PA devices where safety and reliability is required. At the data link layer, Profibus ...12 e. Profibus

  13. Wind Turbine Fault Detection based on Artificial Neural Network Analysis of SCADA Data

    DEFF Research Database (Denmark)

    Herp, Jürgen; S. Nadimi, Esmaeil

    2015-01-01

    Slowly developing faults in wind turbine can, when not detected and fixed on time, cause severe damage and downtime. We are proposing a fault detection method based on Artificial Neural Networks (ANN) and the recordings from Supervisory Control and Data Acquisition (SCADA) systems installed in wind...

  14. JACoW Integration of the vacuum SCADA with CERN's Enterprise Asset Management system

    CERN Document Server

    Rocha, Andre; Fraga, Jorge; Gkioka, Georgia; Gomes, Paulo; Gonzalez, Luis; Krastev, Tsvetelin; Riddone, Germana; Widegren, David

    2018-01-01

    With over 128Km of vacuum chambers, reaching pressures as low as in interstellar space, CERN is home to the largest vacuum system in the world. Its underlying architecture comprises approximately 15 000 pieces of control equipment, supervised and controlled by 7 Supervisory Control And Data Acquisition (SCADA) servers, and over 300 Programmable Logic Controllers (PLCs). Their configuration files are automatically generated from a set of ORACLE databases (vacDB) using a Java application (vacDB-Editor). The maintenance management of such an amount of equipment requires the usage of an Enterprise Asset Management system (EAM), where the life cycle of every equipment is tracked from reception through decommissioning. The equipment displayed in the vacuum SCADA is automatically integrated in its user interfaces (UIs) based on data available on vacDB. On the other hand, the equipment available in Infor-EAM for maintenance management activities (creation of work-orders, stock management, location tracking) resides i...

  15. Enlace de reconectadores a un sistema SCADA mediante una red de comunicaciones

    Directory of Open Access Journals (Sweden)

    Juan Ortega Castro

    2016-12-01

    Abstract The following paper details the link methodology from a communications network for the SCADA system at Azogues Power Company (EEA, starting from the need to implement electric reconnectors in the short and medium term; using automatic reconnectors OSM for their versatility and endurance when used outdoors, IEC 870 DNP3 communications protocols and ModBus for SCADA systems and remote terminal units. This way there is an improvement in the quality of the power supply service that is distributed in Azogues and its parishes. For this task, an implementation design of a communications network was done, in order to link the new reconnectors that were acquired by the company; setting a priority of the infrastructure and resources that it already had, achieving the placement of eight of these devices that were distributed in different areas of the city, using optic fiber in some cases and radio links in other situations when the network infrastructure didn’t allow the physical access to the facility; everything backed up with the correspondent technical and financial studies

  16. Cyber Security Testing and Training Programs for Industrial Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Daniel Noyes

    2012-03-01

    Service providers rely on industrial control systems (ICS) to manage the flow of water at dams, open breakers on power grids, control ventilation and cooling in nuclear power plants, and more. In today's interconnected environment, this can present a serious cyber security challenge. To combat this growing challenge, government, private industry, and academia are working together to reduce cyber risks. The Idaho National Laboratory (INL) is a key contributor to the Department of Energy National SCADA Test Bed (NSTB) and the Department of Homeland Security (DHS) Control Systems Security Program (CSSP), both of which focus on improving the overall security posture of ICS in the national critical infrastructure. In support of the NSTB, INL hosts a dedicated SCADA testing facility which consists of multiple control systems supplied by leading national and international manufacturers. Within the test bed, INL researchers systematically examine control system components and work to identify vulnerabilities. In support of the CSSP, INL develops and conducts training courses which are designed to increase awareness and defensive capabilities for IT/Control System professionals. These trainings vary from web-based cyber security trainings for control systems engineers to more advanced hands-on training that culminates with a Red Team/ Blue Team exercise that is conducted within an actual control systems environment. INL also provides staffing and operational support to the DHS Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) Security Operations Center which responds to and analyzes control systems cyber incidents across the 18 US critical infrastructure sectors.

  17. Carboy Security Testing and Training Programs for Industrial Control Systems

    International Nuclear Information System (INIS)

    Noyes, Daniel

    2012-01-01

    Service providers rely on industrial control systems (ICS) to manage the flow of water at dams, open breakers on power grids, control ventilation and cooling in nuclear power plants, and more. In today's interconnected environment, this can present a serious cyber security challenge. To combat this growing challenge, government, private industry, and academia are working together to reduce cyber risks. The Idaho National Laboratory (INL) is a key contributor to the Department of Energy National SCADA Test Bed (NSTB) and the Department of Homeland Security (DHS) Control Systems Security Program (CSSP), both of which focus on improving the overall security posture of ICS in the national critical infrastructure. In support of the NSTB, INL hosts a dedicated SCADA testing facility which consists of multiple control systems supplied by leading national and international manufacturers. Within the test bed, INL researchers systematically examine control system components and work to identify vulnerabilities. In support of the CSSP, INL develops and conducts training courses which are designed to increase awareness and defensive capabilities for IT/Control System professionals. These training vary from web-based cyber security training for control systems engineers to more advanced hands-on training that culminates with a Red Team/Blue Team exercise that is conducted within an actual control systems environment. INL also provides staffing and operational support to the DHS Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) Security Operations Center which responds to and analyzes control systems cyber incidents across the 18 US critical infrastructure sectors

  18. Cyber Security Testing and Training Programs for Industrial Control Systems

    International Nuclear Information System (INIS)

    Noyes, Daniel

    2012-01-01

    Service providers rely on industrial control systems (ICS) to manage the flow of water at dams, open breakers on power grids, control ventilation and cooling in nuclear power plants, and more. In today's interconnected environment, this can present a serious cyber security challenge. To combat this growing challenge, government, private industry, and academia are working together to reduce cyber risks. The Idaho National Laboratory (INL) is a key contributor to the Department of Energy National SCADA Test Bed (NSTB) and the Department of Homeland Security (DHS) Control Systems Security Program (CSSP), both of which focus on improving the overall security posture of ICS in the national critical infrastructure. In support of the NSTB, INL hosts a dedicated SCADA testing facility which consists of multiple control systems supplied by leading national and international manufacturers. Within the test bed, INL researchers systematically examine control system components and work to identify vulnerabilities. In support of the CSSP, INL develops and conducts training courses which are designed to increase awareness and defensive capabilities for IT/Control System professionals. These trainings vary from web-based cyber security trainings for control systems engineers to more advanced hands-on training that culminates with a Red Team/ Blue Team exercise that is conducted within an actual control systems environment. INL also provides staffing and operational support to the DHS Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) Security Operations Center which responds to and analyzes control systems cyber incidents across the 18 US critical infrastructure sectors.

  19. Carboy Security Testing and Training Programs for Industrial Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Noyes, Daniel [Idaho National Laboratory, Idaho (United States)

    2012-03-15

    Service providers rely on industrial control systems (ICS) to manage the flow of water at dams, open breakers on power grids, control ventilation and cooling in nuclear power plants, and more. In today's interconnected environment, this can present a serious cyber security challenge. To combat this growing challenge, government, private industry, and academia are working together to reduce cyber risks. The Idaho National Laboratory (INL) is a key contributor to the Department of Energy National SCADA Test Bed (NSTB) and the Department of Homeland Security (DHS) Control Systems Security Program (CSSP), both of which focus on improving the overall security posture of ICS in the national critical infrastructure. In support of the NSTB, INL hosts a dedicated SCADA testing facility which consists of multiple control systems supplied by leading national and international manufacturers. Within the test bed, INL researchers systematically examine control system components and work to identify vulnerabilities. In support of the CSSP, INL develops and conducts training courses which are designed to increase awareness and defensive capabilities for IT/Control System professionals. These training vary from web-based cyber security training for control systems engineers to more advanced hands-on training that culminates with a Red Team/Blue Team exercise that is conducted within an actual control systems environment. INL also provides staffing and operational support to the DHS Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) Security Operations Center which responds to and analyzes control systems cyber incidents across the 18 US critical infrastructure sectors.

  20. MULTILINGUAL RECODING METHOD DESIGNED FOR SCADA-SYSTEM’S SOFTWARE UPGRADE

    Directory of Open Access Journals (Sweden)

    S. Velykodniy

    2017-06-01

    Full Text Available The article discusses a new approach to upgrade the software for SCADA-systems. A distinctive feature of this method is the ability to support more than ten most popular programming languages. By applying this method it’s possible to automate the process of recoding software components and, by doing so, it saves time programmers have to spend to rewrite the code and reduce the likelihood of structural errors inherited from the previous system.

  1. CÁLCULO Y DISEÑO DE UN SISTEMA DE CONTROL MEDIANTE LA IMPLEMENTACION DE UN SOFTWARE SCADA EN EL CURSO DE PROYECTO INTEGRADOR II

    Directory of Open Access Journals (Sweden)

    Karla Puerto-López

    2014-12-01

    Full Text Available El objetivo de este documento es ilustrar cada una de etapas que intervienen en el diseño de un sistema SCADA (Supervisory Control And Data Adquisition partiendo de la elaboración de layout estructural mecánico, potencia eléctrica orientado a procesos industriales El objetivo de este trabajo es analizar y especificar los requerimientos para software SCADA (Supervisory Control And Data Adquisition orientados a todo tipo de empresas del sector industrial. Se presentan los análisis efectuados a software SCADA comerciales relevando los usuarios existentes en el mercado. Además se presenta un análisis basado en un desarrollo propio realizado con un lenguaje de propósito general.

  2. A Survey of Research in Supervisory Control and Data Acquisition (SCADA)

    Science.gov (United States)

    2014-09-01

    RISC ) platforms running some version of UNIX.4 Around the turn of the millennium work began on applying Web technologies to SCADA systems.5–8 Lately...the 2 trend has been to move from the UNIX/ RISC system to commodity hardware and Microsoft solutions although there is some Linux,1 to move from...Control Center MTU Master Terminal Unit OS operating system PKI Public Key Infrastructure PLC Programmable Logic Controller RISC Reduced Instruction

  3. SCADA based radioactive sample bottle delivery system for fuel reprocessing project

    International Nuclear Information System (INIS)

    Kaushik, Subrat; Munj, Niket; Chauhan, R.K.; Jayaram, M.N.; Haneef, K.K.M.

    2014-01-01

    Radioactive samples of process streams need to be analyzed in centralized control lab for measuring concentration of heavy elements as well as activity at various stages of re-processing plants. The sample is taken from biologically shielded process cells remotely through sampling blisters in sample bottles. These are then transferred to control lab located about 50 meters using vacuum transfer system. The bottle movement is tracked from origin to destination in rich HMI SCADA system using Infra-red non contact type proximity sensors located along sampling line and these sensors are connected to PLC in a fail-safe mode. The sample bottle travels at a speed of 10 m/s under vacuum motive force and the detection time is of the order of 1 mS. The flow meters have been used to know the air flow in sampling line. The system has been designed, developed, tested and commissioned and in use for four years. (author)

  4. Why SCADA security is NOT like Computer Centre Security

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    Today, the industralized world lives in symbiosis with control systems (aka SCADA systems): it depends on power distribution, oil production, public transport, automatic production lines. While the convenience is at hand, still too many control systems are designed without any security in mind, lack basic security protections, and are not even robust enough to withstand basic attacks. The Stuxnet worm attacking Siemens PLCs in 2010 was another close call. Attackers currently enjoy hacking control systems, and aim to switch lights off. This presentation shall recap the current situation and discuss the differences (or not) between computer center cyber-security and control system cyber-security.

  5. SCADA for microtron and beam transport line radio therapy machine subsystem

    International Nuclear Information System (INIS)

    Deshpande, Praveen; Palod, Shradha; Bhujle, Ashok

    2003-01-01

    Centre for Advanced Technology is developing a Radio Therapy Machine (RTM) to be used for cancer treatment. The radiotherapy machine has a Microtron consisting of a RF system, main and auxiliary magnets. It has a Beam transport line (BTL) consisting of fourteen magnets. This paper describes a PC based supervisory control and data acquisition system (SCADA) developed for controlling mainly the power supplies for the above sub systems from a remote location. It offers a graphic user interface (GUI) at the control room PC for RTM operation in engineering mode

  6. Propuesta de gestión de riesgos para Scada en sistemas eléctricos

    Directory of Open Access Journals (Sweden)

    María J. Bernal Zuluaga

    2012-12-01

    Full Text Available En la actualidad los ataques cibernéticos son uno de los principales aspectos a considerar por parte de los entes gubernamentales y por las empresas prestadoras de servicios públicos, dado que dichas entidades son el blanco preferido para desestabilizar el normal desempeño de las actividades de un sector determinado. En particular, la prestación del servicio eléctrico es fundamental para la operación de la mayor parte de las actividades diarias a nivel comercial, industrial y social de nuestro país. Los centros de control eléctricos cuentan con el Sistema SCADA para tener información en tiempo real que facilite la supervisión, control y toma de decisiones necesarias para garantizar la seguridad y calidad en la prestación del servicio eléctrico. Este artículo trata de la gestión de riesgos del sistema SCADA y la definición de un plan de tratamiento en el cual se exponen las medidas de control que deben ser implementadas para la mitigación de los riesgos a los cuales está expuesto dicho sistema.

  7. Disain Sistem SCADA jarak Jauh Menggunakan Layanan VPN 3G Untuk Penggerak Pompa pada Sistem Pengolahan Air

    Directory of Open Access Journals (Sweden)

    Asep Insani

    2013-03-01

    Full Text Available Dalam pengolahan air gambut menjadi air bersih yang menggunakan metode AOP dan RO ini, pengaturan tekanan pompa merupakan sesuatu yang sangat vital pada saat dilakukan suplay air yang akan diolah ke sistem. Sistem pengolahan air yang menggunakan pompa tersebut harus selalu dipastikan beroperasi dengan normal disesuaikan dengan peruntukannya. Manajemen terbaru sistem pengolahan air memerlukan teknologi yang terbaru pada peralatan remote control system, dan yang paling fundamental untuk hal ini adalah penggunaan layanan public untuk akusisi dan pengawasan dari data yang diambil dari peralatan kontrol. Untuk mewujudkan remote control untuk pompa dengan tekanan tertentu dengan PLC, didisain dengan kombinasi antara internet, arsitektur dan implementasi dari sistem SCADA, yang menggabungkan jaringan komputer, PLC, WinCC, dan teknologi VPN. Dalam melakukan disain, perlu diperhatikan poin-poin penting baik dari sisi server maupun sisi controller. Disain sistem SCADA remote dapat mengefisienkan waktu bagi operator dan pemantauan lebih lanjut untuk suplay air.

  8. Combating Memory Corruption Attacks On Scada Devices

    Science.gov (United States)

    Bellettini, Carlo; Rrushi, Julian

    Memory corruption attacks on SCADA devices can cause significant disruptions to control systems and the industrial processes they operate. However, despite the presence of numerous memory corruption vulnerabilities, few, if any, techniques have been proposed for addressing the vulnerabilities or for combating memory corruption attacks. This paper describes a technique for defending against memory corruption attacks by enforcing logical boundaries between potentially hostile data and safe data in protected processes. The technique encrypts all input data using random keys; the encrypted data is stored in main memory and is decrypted according to the principle of least privilege just before it is processed by the CPU. The defensive technique affects the precision with which attackers can corrupt control data and pure data, protecting against code injection and arc injection attacks, and alleviating problems posed by the incomparability of mitigation techniques. An experimental evaluation involving the popular Modbus protocol demonstrates the feasibility and efficiency of the defensive technique.

  9. Modeling of quasi-static thrust load of wind turbines based on 1 s SCADA data

    Directory of Open Access Journals (Sweden)

    N. Noppe

    2018-03-01

    Full Text Available A reliable load history is crucial for a fatigue assessment of wind turbines. However, installing strain sensors on every wind turbine is not economically feasible. In this paper, a technique is proposed to reconstruct the thrust load history of a wind turbine based on high-frequency Supervisory Control and Data Acquisition (SCADA data. Strain measurements recorded during a short period of time are used to train a neural network. The selection of appropriate input parameters is performed based on Pearson correlation and mutual information. Once the training is done, the model can be used to predict the thrust load based on SCADA data only. The technique is validated on two different datasets, one consisting of simulation data (using the software FAST v8, created by Jonkman and Jonkman, 2016 obtained in a controllable environment and one consisting of measurements taken at an offshore wind turbine. In general, the relative error between simulated or measured and predicted thrust load barely exceeds 15 % during normal operation.

  10. LESSONS LEARNED FROM CYBER SECURITY ASSESSMENTS OF SCADA AND ENERGY MANAGEMENT SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Ray Fink

    2006-10-01

    The results from ten cyber security vulnerability assessments of process control, SCADA and energy management systems, or components of those systems were reviewed to identify common problem areas. The common vulnerabilities ranged from conventional IT security issues to specific weaknesses in control system protocols. In each vulnerability category, relative measures were assigned to the severity of the vulnerability and ease with which an attacker could exploit the vulnerability. Suggested mitigations are identified in each category. Recommended mitigations having the highest impact on reducing vulnerability are listed for asset owners and system vendors.

  11. Computer-Based Monitoring and Remote Controlling for Oil Well Pumps Using Scada

    Directory of Open Access Journals (Sweden)

    Rudi Tjiptadi

    2011-12-01

    Full Text Available The research aims to change manually the monitoring and controlling of oil well pumps into a computer-based system using SCADA (Supervisory and Data Acquisition system. To design the protection system which consists of controller unit and display system, RTU (Remote Terminal Unit and MTU (Master Terminal Unit are used. The research results in a controller unit which is able to communicate to personal computer using RS-232 C and an alarm system to protect oil pump motors by detecting sensors installed at the pumps. 

  12. Wind turbine condition monitoring based on SCADA data using normal behavior models

    DEFF Research Database (Denmark)

    Schlechtingen, Meik; Santos, Ilmar

    2014-01-01

    system (ANFIS) models in this context and the application of a proposed procedure to a wide range of different SCADA signals. The applicability of the set up ANFIS models for anomaly detection was proven by the achieved performance of the models. In combination with the fuzzy interference system (FIS......) a hydraulic oil leakage; (2) cooling system filter obstructions; (3) converter fan malfunctions; (4) anemometer offsets and (5) turbine controller malfunctions. Moreover, the graphical user interface (GUI) developed to access, analyze and visualize the data and results is presented....

  13. Diseño e implantación de un sistema SCADA para una planta de producción y envasado de líquidos

    OpenAIRE

    Redondo Sol, Manuel

    2008-01-01

    Este proyecto consiste en la implantación de un sistema SCADA en una planta piloto de fabricación y envasado de líquidos. En este documento se muestra toda la información que ha sido necesaria para realizar el sistema de automatización en los tres niveles propios de un SCADA: nivel de campo, nivel de control y nivel de supervisión. El trabajo de campo ha sido, típicamente de revisión, puesto que el Departament de Telecomunicació i d'Enginyeria de Sistemes ya poseía la planta totalmente equipa...

  14. Design and development of an IoT-based web application for an intelligent remote SCADA system

    Science.gov (United States)

    Kao, Kuang-Chi; Chieng, Wei-Hua; Jeng, Shyr-Long

    2018-03-01

    This paper presents a design of an intelligent remote electrical power supervisory control and data acquisition (SCADA) system based on the Internet of Things (IoT), with Internet Information Services (IIS) for setting up web servers, an ASP.NET model-view- controller (MVC) for establishing a remote electrical power monitoring and control system by using responsive web design (RWD), and a Microsoft SQL Server as the database. With the web browser connected to the Internet, the sensing data is sent to the client by using the TCP/IP protocol, which supports mobile devices with different screen sizes. The users can provide instructions immediately without being present to check the conditions, which considerably reduces labor and time costs. The developed system incorporates a remote measuring function by using a wireless sensor network and utilizes a visual interface to make the human-machine interface (HMI) more instinctive. Moreover, it contains an analog input/output and a basic digital input/output that can be applied to a motor driver and an inverter for integration with a remote SCADA system based on IoT, and thus achieve efficient power management.

  15. Improving Security for SCADA Sensor Networks with Reputation Systems and Self-Organizing Maps

    Directory of Open Access Journals (Sweden)

    Javier Blesa

    2009-11-01

    Full Text Available The reliable operation of modern infrastructures depends on computerized systems and Supervisory Control and Data Acquisition (SCADA systems, which are also based on the data obtained from sensor networks. The inherent limitations of the sensor devices make them extremely vulnerable to cyberwarfare/cyberterrorism attacks. In this paper, we propose a reputation system enhanced with distributed agents, based on unsupervised learning algorithms (self-organizing maps, in order to achieve fault tolerance and enhanced resistance to previously unknown attacks. This approach has been extensively simulated and compared with previous proposals.

  16. Desarrollo de un sistema SCADA para el abastecimineto de agua en la estación de bombeo Yuyucocha de la empresa municipal de agua potable y alcantarillado de Ibarra

    OpenAIRE

    Murillo Moreno, Darío Hernán

    2018-01-01

    The present technical project was developed in the Municipal Drinking Water and Sewerage Company of Ibarra with the purpose of developing a SCADA system for the water supply system in the Yuyucocha pumping station, using fiber optic for the connection between three wells and the control room. The SCADA system of the Yuyucocha pumping station allows the continuous monitoring and control of the equipment that is used for the administration of drinking water in the city of Ibarra. Furthermore, t...

  17. Design and implementation of HMI and SCADA applied to a didactic emulation of a packing process

    Directory of Open Access Journals (Sweden)

    Manuel Alejandro Bohórquez-Dallos

    2013-07-01

    The supervision and control of the signals are performed with the CANopen protocol. The developed system allows the user to interact directly with the emulation of the process, triggering elements of it in the computer remotely and locally using the touch screen. The SCADA and HMI are embedded in a CoDeSys® function that the user can use as a learning tool for automating the process emulation.

  18. A virtual computing infrastructure for TS-CV SCADA systems

    CERN Document Server

    Poulsen, S

    2008-01-01

    In modern data centres, it is an emerging trend to operate and manage computers as software components or logical resources and not as physical machines. This technique is known as â€ワvirtualisation” and the new computers are referred to as â€ワvirtual machines” (VMs). Multiple VMs can be consolidated on a single hardware platform and managed in ways that are not possible with physical machines. However, this is not yet widely practiced for control system deployment. In TS-CV, a collection of VMs or a â€ワvirtual infrastructure” is installed since 2005 for SCADA systems, PLC program development, and alarm transmission. This makes it possible to consolidate distributed, heterogeneous operating systems and applications on a limited number of standardised high-performance servers in the Central Control Room (CCR). More generally, virtualisation assists in offering continuous computing services for controls and maintaining performance and assuring quality. Implementing our systems in a vi...

  19. Actualización del sistema SCADA y de control para los reactores MQ5 y MQ6 de la planta de Pinturas Condor, Sherwin Williams Ecuador

    Directory of Open Access Journals (Sweden)

    Jonathan Reinoso

    2013-12-01

    Full Text Available El presente documento describe la actualización del sistema SCADA para los reactores MQ5 y MQ6 de la planta de Pinturas Condor mediante el software Intouch y la actualización del sistema de control del reactor MQ5 implementado en un controlador lógico programable (PLC de marca SCHNEIDER, además de la arquitectura de control realizada en el proyecto. El sistema SCADA y de control de los reactores permiten la visualización y control de los datos y variables más relevantes durante las diferentes fases de producción de resinas en los reactores MQ5 y MQ6.

  20. The Danish National Tests

    DEFF Research Database (Denmark)

    Beuchert, Louise Voldby; Nandrup, Anne Brink

    In 2010, the Danish National Tests were implemented in the public compulsory schools as a mean of evaluating the performance of the public school system. The extensive test program consists of ten mandatory tests in six subjects in grades 2 through 8. In this paper, we share our insights from wor...... characteristics as well as pupils' 9th grade examination marks. We document a stable test score gap across grade levels and socio economic background and discuss the prospects of the national test data for future research....... within each test and argue that this is often a more feasible measure for data analyses compared to the transformed test score presented to pupils and teachers. We provide the reader with preliminary analyses of the relation between pupils' national test results and a wide range of pupil background...

  1. Secure Data Transfer Guidance for Industrial Control and SCADA Systems

    Energy Technology Data Exchange (ETDEWEB)

    Mahan, Robert E.; Fluckiger, Jerry D.; Clements, Samuel L.; Tews, Cody W.; Burnette, John R.; Goranson, Craig A.; Kirkham, Harold

    2011-09-01

    This document was developed to provide guidance for the implementation of secure data transfer in a complex computational infrastructure representative of the electric power and oil and natural gas enterprises and the control systems they implement. For the past 20 years the cyber security community has focused on preventative measures intended to keep systems secure by providing a hard outer shell that is difficult to penetrate. Over time, the hard exterior, soft interior focus changed to focus on defense-in-depth adding multiple layers of protection, introducing intrusion detection systems, more effective incident response and cleanup, and many other security measures. Despite much larger expenditures and more layers of defense, successful attacks have only increased in number and severity. Consequently, it is time to re-focus the conventional approach to cyber security. While it is still important to implement measures to keep intruders out, a new protection paradigm is warranted that is aimed at discovering attempted or real compromises as early as possible. Put simply, organizations should take as fact that they have been, are now, or will be compromised. These compromises may be intended to steal information for financial gain as in the theft of intellectual property or credentials that lead to the theft of financial resources, or to lie silent until instructed to cause physical or electronic damage and/or denial of services. This change in outlook has been recently confirmed by the National Security Agency [19]. The discovery of attempted and actual compromises requires an increased focus on monitoring events by manual and/or automated log monitoring, detecting unauthorized changes to a system's hardware and/or software, detecting intrusions, and/or discovering the exfiltration of sensitive information and/or attempts to send inappropriate commands to ICS/SCADA (Industrial Control System/Supervisory Control And Data Acquisition) systems.

  2. SCADA based radioactive sample bottle delivery system for fuel reprocessing project

    International Nuclear Information System (INIS)

    Kaushik, Subrat; Munj, Niket; Chauhan, R.K.; Kumar, Pramod; Mishra, A.C.

    2011-01-01

    Radioactive samples of process streams need to be analyzed in centralized control lab for measuring concentration of heavy elements as well as activity at various stages of re-processing plants. The sample is taken from biologically shielded process cells remotely through sampling blisters in sample bottles. These are then transferred to control lab located about 50 meters using vacuum transfer system. The bottle movement is tracked from origin to destination in rich HMI SCADA system using Infra-red non contact type proximity sensors located along sampling line and these sensors are connected to PLC in a fail-safe mode. The sample bottle travels at a speed of 10 m/s under vacuum motive force and the detection time is of the order of 1 mS. The contact time Flow meters have been used to know the air flow in sampling line

  3. National HIV Testing Day

    Centers for Disease Control (CDC) Podcasts

    2011-06-09

    Dr. Kevin A. Fenton, Director of CDC's National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention, discusses National HIV Testing Day, an annual observance which raises awareness of the importance of knowing one's HIV status and encourages at-risk individuals to get an HIV test.  Created: 6/9/2011 by National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention (NCHHSTP).   Date Released: 6/9/2011.

  4. National HIV Testing Day

    Centers for Disease Control (CDC) Podcasts

    Dr. Kevin A. Fenton, Director of CDC's National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention, discusses National HIV Testing Day, an annual observance which raises awareness of the importance of knowing one's HIV status and encourages at-risk individuals to get an HIV test.

  5. Multi-platform SCADA GUI Regression Testing at CERN

    CERN Document Server

    Burkimsher, P C; Klikovits, S

    2011-01-01

    The JCOP Framework is a toolkit used widely at CERN for the development of industrial control systems in several domains (i.e. experiments, accelerators and technical infrastructure). The software development started 10 years ago and there is now a large base of production systems running it. For the success of the project, it was essential to formalize and automate the quality assurance process. This paper will present the overall testing strategy and will describe in detail mechanisms used for GUI testing. The choice of a commercial tool (Squish) and the architectural features making it appropriate for our multi-platform environment will be described. Practical difficulties encountered when using the tool in the CERN context are discussed as well as how these were addressed. In the light of initial experience, the test code itself has been recently reworked in object-oriented style to facilitate future maintenance and extension. The current reporting process is described, as well as future plans for easy re...

  6. National Tests and minorities

    DEFF Research Database (Denmark)

    Andreasen, Karen Egedal

    Assessment in school represent a technology and materiality with profound impact on the life, activities and interactions in school (eg. Lawn & Grosvenor, 2005). It can be considered as an integrated and in different ways also dominating part of pedagogic practice which influence processes of in...... – in the classroom – as well as at the macro level – the nation.The practice of teachers offering national tests occurs in different forms in primary schools throughout the world (eg. McNess et al. 2015). These practices are often associated with a curriculum and learning objectives that are nationalistic...... in their orientation. In a policy perspective, the underlying motive may be a desire to evaluate and compare students’ academic development and performance as well as schools’ performance and goal attainment at the national level. National testing are based on the assumption that the tested pupils all speak the same...

  7. The inherent weaknesses in industrial control systems devices; hacking and defending SCADA systems

    Science.gov (United States)

    Bianco, Louis J.

    The North American Electric Reliability Corporation (NERC) is about to enforce their NERC Critical Infrastructure Protection (CIP) Version Five and Six requirements on July 1st 2016. The NERC CIP requirements are a set of cyber security standards designed to protect cyber assets essential the reliable operation of the electric grid. The new Version Five and Six requirements are a major revision to the Version Three (currently enforced) requirements. The new requirements also bring substations into scope alongside Energy Control Centers. When the Version Five requirements were originally drafted they were vague, causing in depth discussions throughout the industry. The ramifications of these requirements has made owners look at their systems in depth, questioning how much money it will take to meet these requirements. Some owners saw backing down from routable networks to non-routable as a means to save money as they would be held to less requirements within the standards. Some owners saw removing routable connections as a proper security move. The purpose of this research was to uncover the inherent weaknesses in Industrial Control Systems (ICS) devices; to show how ICS devices can be hacked and figure out potential protections for these Critical Infrastructure devices. In addition, this research also aimed to validate the decision to move from External Routable connectivity to Non-Routable connectivity, as a security measure and not as a means of savings. The results reveal in order to ultimately protect Industrial Control Systems they must be removed from the Internet and all bi-directional external routable connections must be removed. Furthermore; non-routable serial connections should be utilized, and these non-routable serial connections should be encrypted on different layers of the OSI model. The research concluded that most weaknesses in SCADA systems are due to the inherent weaknesses in ICS devices and because of these weaknesses, human intervention is

  8. Software and hardware platform for testing of Automatic Generation Control algorithms

    Directory of Open Access Journals (Sweden)

    Vasiliev Alexey

    2017-01-01

    Full Text Available Development and implementation of new Automatic Generation Control (AGC algorithms requires testing them on a model that adequately simulates primary energetic, information and control processes. In this article an implementation of a test platform based on HRTSim (Hybrid Real Time Simulator and SCADA CK-2007 (which is widely used by the System Operator of Russia is proposed. Testing of AGC algorithms on the test platform based on the same SCADA system that is used in operation allows to exclude errors associated with the transfer of AGC algorithms and settings from the test platform to a real power system. A power system including relay protection, automatic control systems and emergency control automatics can be accurately simulated on HRTSim. Besides the information commonly used by conventional AGC systems HRTSim is able to provide a resemblance of Phasor Measurement Unit (PMU measurements (information about rotor angles, magnitudes and phase angles of currents and voltages etc.. The additional information significantly expands the number of possible AGC algorithms so the test platform is useful in modern AGC system developing. The obtained test results confirm that the proposed system is applicable for the tasks mentioned above.

  9. Development of Supervisory Control and Data Acquisition (SCADA) Electrical Supply in Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Zainudin Jaafar; Mohd Ashhar Khalid; Mohd Hanafiah Chik

    2015-01-01

    Nuclear Power supplies in Malaysia supplied from the power utility company Tenaga Nasional Berhad through several substations before reaching the building and equipment. The power supply is received and passed down through the 11000 V high voltage switch gears to 415 V 3-phase or 1-phase 240 V. The equipment used in this process is dangerous and monitoring hardware operating remotely (remote) is the best as only guard machinery may engage in business operations. Similarly, the supply of electrical parameters should be monitored to ensure safe and continuous supply of and according to the appropriate voltage for record and analysis when needed. This paper discusses the monitoring and data acquisition is performed using the system 'Supervisory Control And Data Acquisition (SCADA) was developed. (author)

  10. Modeling DNP3 Traffic Characteristics of Field Devices in SCADA Systems of the Smart Grid

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Huan [Lehigh Univ., Bethlehem, PA (United States); Cheng, Liang [Lehigh Univ., Bethlehem, PA (United States); Chuah, Mooi Choo [Lehigh Univ., Bethlehem, PA (United States)

    2017-03-08

    In the generation, transmission, and distribution sectors of the smart grid, intelligence of field devices is realized by programmable logic controllers (PLCs). Many smart-grid subsystems are essentially cyber-physical energy systems (CPES): For instance, the power system process (i.e., the physical part) within a substation is monitored and controlled by a SCADA network with hosts running miscellaneous applications (i.e., the cyber part). To study the interactions between the cyber and physical components of a CPES, several co-simulation platforms have been proposed. However, the network simulators/emulators of these platforms do not include a detailed traffic model that takes into account the impacts of the execution model of PLCs on traffic characteristics. As a result, network traces generated by co-simulation only reveal the impacts of the physical process on the contents of the traffic generated by SCADA hosts, whereas the distinction between PLCs and computing nodes (e.g., a hardened computer running a process visualization application) has been overlooked. To generate realistic network traces using co-simulation for the design and evaluation of applications relying on accurate traffic profiles, it is necessary to establish a traffic model for PLCs. In this work, we propose a parameterized model for PLCs that can be incorporated into existing co-simulation platforms. We focus on the DNP3 subsystem of slave PLCs, which automates the processing of packets from the DNP3 master. To validate our approach, we extract model parameters from both the configuration and network traces of real PLCs. Simulated network traces are generated and compared against those from PLCs. Our evaluation shows that our proposed model captures the essential traffic characteristics of DNP3 slave PLCs, which can be used to extend existing co-simulation platforms and gain further insights into the behaviors of CPES.

  11. Protocol converter for serial communication between digital rectifier controllers and a power plant SCADA system

    Directory of Open Access Journals (Sweden)

    Vukić Vladimir Đ.

    2016-01-01

    Full Text Available The paper describes the protocol converter INT-485-MBRTU, developed for serial communication between the thyristor rectifier (based on the proprietary protocol "INT-CPD-05", according to standard RS-485 and the SCADA system (based on protocol "Modbus RTU", of the same standard in the thermal power plant "Nikola Tesla B1". Elementary data on industrial communication protocols and communication gateways were provided. The basic technical characteristics of the "Omron" programmable logic controller CJ series were described, as well as the developed device INT-485-MBRTU. Protocol converters with two versions of communication software were tested, differing only in one control word, intended for a forced successive change of communication sequences, in opposite to automatic sequence relieve. The device iNT-485-MBRTU, with the program for forced successive change of communication sequences, demonstrated the reliability of data transfer of 100 %, in a sample of approximately 480 messages. For nearly the same sample, the same protocol converter, with a version of the program without any type of message identifiers, transferred less than 60 % of the foreseen data. During multiple sixty-hour tests, the reliability of data transfer of at least 99.9979% was recorded, in 100% of the analysed cases, and for a sample of nearly 96,000 pairs of the send and receive messages. We analysed the results and estimated the additional possibilities for application of the INT-485-MBRTU protocol converter.

  12. LHC-GCS a model-driven approach for automatic PLC and SCADA code generation

    CERN Document Server

    Thomas, Geraldine; Barillère, Renaud; Cabaret, Sebastien; Kulman, Nikolay; Pons, Xavier; Rochez, Jacques

    2005-01-01

    The LHC experiments’ Gas Control System (LHC GCS) project [1] aims to provide the four LHC experiments (ALICE, ATLAS, CMS and LHCb) with control for their 23 gas systems. To ease the production and maintenance of 23 control systems, a model-driven approach has been adopted to generate automatically the code for the Programmable Logic Controllers (PLCs) and for the Supervision Control And Data Acquisition (SCADA) systems. The first milestones of the project have been achieved. The LHC GCS framework [4] and the generation tools have been produced. A first control application has actually been generated and is in production, and a second is in preparation. This paper describes the principle and the architecture of the model-driven solution. It will in particular detail how the model-driven solution fits with the LHC GCS framework and with the UNICOS [5] data-driven tools.

  13. PV-Diesel Hybrid SCADA Experiment Network Design

    Science.gov (United States)

    Kalu, Alex; Durand, S.; Emrich, Carol; Ventre, G.; Wilson, W.; Acosta, R.

    1999-01-01

    The essential features of an experimental network for renewable power system satellite based supervisory, control and data acquisition (SCADA) are communication links, controllers, diagnostic equipment and a hybrid power system. Required components for implementing the network consist of two satellite ground stations, to satellite modems, two 486 PCs, two telephone receivers, two telephone modems, two analog telephone lines, one digital telephone line, a hybrid-power system equipped with controller and a satellite spacecraft. In the technology verification experiment (TVE) conducted by Savannah State University and Florida Solar Energy Center, the renewable energy hybrid system is the Apex-1000 Mini-Hybrid which is equipped with NGC3188 for user interface and remote control and the NGC2010 for monitoring and basic control tasks. This power system is connected to a satellite modem via a smart interface, RS232. Commands are sent to the power system control unit through a control PC designed as PC1. PC1 is thus connected to a satellite model through RS232. A second PC, designated PC2, the diagnostic PC is connected to both satellite modems via separate analog telephone lines for checking modems'health. PC2 is also connected to PC1 via a telephone line. Due to the unavailability of a second ground station for the ACTS, one ground station is used to serve both the sending and receiving functions in this experiment. Signal is sent from the control PC to the Hybrid system at a frequency f(sub 1), different from f(sub 2), the signal from the hybrid system to the control PC. f(sub l) and f(sub 2) are sufficiently separated to avoid interference.

  14. Experimental validation of control strategies for a microgrid test facility including a storage system and renewable generation sets

    DEFF Research Database (Denmark)

    Baccino, Francesco; Marinelli, Mattia; Silvestro, Federico

    2012-01-01

    The paper is aimed at describing and validating some control strategies in the SYSLAB experimental test facility characterized by the presence of a low voltage network with a 15 kW-190 kWh Vanadium Redox Flow battery system and a 11 kW wind turbine. The generation set is connected to the local...... network and is fully controllable by the SCADA system. The control strategies, implemented on a local pc interfaced to the SCADA, are realized in Matlab-Simulink. The main purpose is to control the charge/discharge action of the storage system in order to present at the point of common coupling...... the desired power or energy profiles....

  15. CENRTC Project number-sign 2F3EOA, OCB A-376, acceptance test procedure

    International Nuclear Information System (INIS)

    Akerson, A.W.

    1995-01-01

    This test procedure provides the steps necessary to verify correct functional operation of controls, annunciators, alarms, protective relays and related systems impacted by CENRTC number-sign 2F3E0A, Microwave Transfer Trip Project, modification work performed under work package 6B-93-00041/M. This procedure separates three tests into separate sections: energization of A-376 duplex panel and circuits; SCADA tests; and A-376 local trip tests

  16. National Solar Thermal Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The National Solar Thermal Test Facility (NSTTF) is the only test facility in the United States of its type. This unique facility provides experimental engineering...

  17. Scada Systems – Control, Supervision and Data Acquisition for the Power Plants Settled on a Stream (Part 2

    Directory of Open Access Journals (Sweden)

    Cosmin Ursoniu

    2015-09-01

    Full Text Available Scada (supervisory control and data acquisition is a complex system that supervises and controls an industrial process and performs several functions. A human machine interface will also be presented and how the process in a power plant is controlled and supervised through it by the operator. The main screen will be described (which is a global view of the hydro unit and what the operator can see and what he can press to control the power plants process also a few more screens will be presented for auxiliary installations and it will be described what the operator can see and what he can do to control the installation.

  18. Scada Systems – Control, Supervision and Data Acquisition for the Power Plants Settled on a Stream (Part 1

    Directory of Open Access Journals (Sweden)

    Cosmin Ursoniu

    2015-09-01

    Full Text Available Scada (supervisory control and data acquisition is a complex system that supervises and control an industrial process and performs several functions. A human machine interface will also be presented and how the process in a power plant is controlled and supervised through it by the operator. The main screen will be described (which is a global view of the hydro unit and what the operator can see and what he can press to control the power plants process also a few more screens will be presented for auxiliary installations and it will be described what the operator can see and what he can do to control the installation.

  19. Testing activities at the National Battery Test Laboratory

    Science.gov (United States)

    Hornstra, F.; Deluca, W. H.; Mulcahey, T. P.

    The National Battery Test Laboratory (NBTL) is an Argonne National Laboratory facility for testing, evaluating, and studying advanced electric storage batteries. The facility tests batteries developed under Department of Energy programs and from private industry. These include batteries intended for future electric vehicle (EV) propulsion, electric utility load leveling (LL), and solar energy storage. Since becoming operational, the NBTL has evaluated well over 1400 cells (generally in the form of three- to six-cell modules, but up to 140-cell batteries) of various technologies. Performance characterization assessments are conducted under a series of charge/discharge cycles with constant current, constant power, peak power, and computer simulated dynamic load profile conditions. Flexible charging algorithms are provided to accommodate the specific needs of each battery under test. Special studies are conducted to explore and optimize charge procedures, to investigate the impact of unique load demands on battery performance, and to analyze the thermal management requirements of battery systems.

  20. PENINGKATAN KEAMANAN SUPERVISORY CONTROL AND DATA ACQUISITION (SCADA PADA SMART GRID SEBAGAI INFRASTRUKTUR KRITIS

    Directory of Open Access Journals (Sweden)

    Ahmad Budi Setiawan

    2016-10-01

    Full Text Available SCADA (Supervisory Control and Data Acquisition systems as the control unit of the smart grid has been used in almost various industries around the world in terms of automation systems. Smart grid technology combines the energy infrastructure and telecommunications and Internet networks. The system provides the operational ease and efficiency in the industry. However, the system has a lot of vulnerabilities in information security aspects that can have a major impact for the industry and even the economy. This study tried to design in building a smart grid cyber security, it includes the strategies that must be done and the information security system architecture to be built. The study was conducted qualitative in-depth interviews, focus group discussions and direct observation. Results of this research is the design strategy recommendations ddalam development of smart grid cyber security. Recommendation results of this study also intended as a suggestion-making framework for smart grid cyber security as a reference implementation of the smart grid in Indonesia.

  1. CENRTC Project number-sign 2F3EOA, OCB A-386, acceptance test procedure

    International Nuclear Information System (INIS)

    Akerson, A.W.

    1995-01-01

    This test procedure provides the steps necessary to verify correct functional operation of controls, annunciators, alarms, protective relays and related systems impacted by CENRTC number-sign 2F3EOA, Microwave Transfer Trip Project, modification work performed under work package 6B-93-00043/M (CENRTC 2F3EOA MWTT OCB A-386 PACKAGE). This procedure separates four tests into separate sections: Energization of A-386 Duplex Panel and Circuits; Local RFL 6750 function tests and start-up; SCADA tests; and A-386 local trip tests

  2. Ensuring US National Aeronautics Test Capabilities

    Science.gov (United States)

    Marshall, Timothy J.

    2010-01-01

    U.S. leadership in aeronautics depends on ready access to technologically advanced, efficient, and affordable aeronautics test capabilities. These systems include major wind tunnels and propulsion test facilities and flight test capabilities. The federal government owns the majority of the major aeronautics test capabilities in the United States, primarily through the National Aeronautics and Space Administration (NASA) and the Department of Defense (DoD). However, changes in the Aerospace landscape, primarily the decrease in demand for testing over the last 20 years required an overarching strategy for management of these national assets. Therefore, NASA established the Aeronautics Test Program (ATP) as a two-pronged strategic initiative to: (1) retain and invest in NASA aeronautics test capabilities considered strategically important to the agency and the nation, and (2) establish a strong, high level partnership with the DoD. Test facility utilization is a critical factor for ATP because it relies on user occupancy fees to recover a substantial part of the operations costs for its facilities. Decreasing utilization is an indicator of excess capacity and in some cases low-risk redundancy (i.e., several facilities with basically the same capability and overall low utilization). However, low utilization does not necessarily translate to lack of strategic importance. Some facilities with relatively low utilization are nonetheless vitally important because of the unique nature of the capability and the foreseeable aeronautics testing needs. Unfortunately, since its inception, the customer base for ATP has continued to shrink. Utilization of ATP wind tunnels has declined by more than 50% from the FY 2006 levels. This significant decrease in customer usage is attributable to several factors, including the overall decline in new programs and projects in the aerospace sector; the impact of computational fluid dynamics (CFD) on the design, development, and research

  3. Accurate Modeling of The Siemens S7 SCADA Protocol For Intrusion Detection And Digital Forensic

    Directory of Open Access Journals (Sweden)

    Amit Kleinmann

    2014-09-01

    Full Text Available The Siemens S7 protocol is commonly used in SCADA systems for communications between a Human Machine Interface (HMI and the Programmable Logic Controllers (PLCs. This paper presents a model-based Intrusion Detection Systems (IDS designed for S7 networks. The approach is based on the key observation that S7 traffic to and from a specific PLC is highly periodic; as a result, each HMI-PLC channel can be modeled using its own unique Deterministic Finite Automaton (DFA. The resulting DFA-based IDS is very sensitive and is able to flag anomalies such as a message appearing out of its position in the normal sequence or a message referring to a single unexpected bit. The intrusion detection approach was evaluated on traffic from two production systems. Despite its high sensitivity, the system had a very low false positive rate - over 99.82% of the traffic was identified as normal.

  4. Controlling the Filling and Capping Operation of a Bottling Plant using PLC and SCADA

    Directory of Open Access Journals (Sweden)

    Kunal Chakraborty

    2015-03-01

    Full Text Available This paper presents basic stages of operation of a bottling plant, i.e. the filling and capping process. The main aim of our paper is to control the filling and capping section of a bottling plant simultaneously. At first a set of empty bottle is run by using a conveyer towards filling section, after the operation, the filled bottles are sent towards the capping section. After successful capping operation, the sealed bottles terminate towards exit and a new set of empty bottle arrive, in this way the process continues. This paper includes the method using which, a bunch of bottles can be filled and capped at one instant of time. This method has made the operation more flexible and time saving. The filling and capping operations are controlled using Programmable Logic Controllers (PLC, as the PLC’s are very much user-efficient, cost-effective and easy to control. By using PLC automation the whole process is kept under control. SCADA (Supervisory Control and Data Acquisition is used to monitor the process by means of a display system.

  5. 49 CFR 192.631 - Control room management.

    Science.gov (United States)

    2010-10-01

    ... control room who monitors and controls all or part of a pipeline facility through a SCADA system. Each... sections 1, 4, 8, 9, 11.1, and 11.3 of API RP 1165 are not practical for the SCADA system used; (2) Conduct... or SCADA displays; (3) Test and verify an internal communication plan to provide adequate means for...

  6. Buffet test in the National Transonic Facility

    Science.gov (United States)

    Young, Clarence P., Jr.; Hergert, Dennis W.; Butler, Thomas W.; Herring, Fred M.

    1992-01-01

    A buffet test of a commercial transport model was accomplished in the National Transonic Facility at the NASA Langley Research Center. This aeroelastic test was unprecedented for this wind tunnel and posed a high risk to the facility. This paper presents the test results from a structural dynamics and aeroelastic response point of view and describes the activities required for the safety analysis and risk assessment. The test was conducted in the same manner as a flutter test and employed onboard dynamic instrumentation, real time dynamic data monitoring, automatic, and manual tunnel interlock systems for protecting the model. The procedures and test techniques employed for this test are expected to serve as the basis for future aeroelastic testing in the National Transonic Facility. This test program was a cooperative effort between the Boeing Commercial Airplane Company and the NASA Langley Research Center.

  7. Proactive monitoring of a wind turbine array with lidar measurements, SCADA data and a data-driven RANS solver

    Science.gov (United States)

    Iungo, G.; Said, E. A.; Santhanagopalan, V.; Zhan, L.

    2016-12-01

    Power production of a wind farm and durability of wind turbines are strongly dependent on non-linear wake interactions occurring within a turbine array. Wake dynamics are highly affected by the specific site conditions, such as topography and local atmospheric conditions. Furthermore, contingencies through the life of a wind farm, such as turbine ageing and off-design operations, make prediction of wake interactions and power performance a great challenge in wind energy. In this work, operations of an onshore wind turbine array were monitored through lidar measurements, SCADA and met-tower data. The atmospheric wind field investing the wind farm was estimated by using synergistically the available data through five different methods, which are characterized by different confidence levels. By combining SCADA data and the lidar measurements, it was possible to estimate power losses connected with wake interactions. For this specific array, power losses were estimated to be 4% and 2% of the total power production for stable and convective atmospheric regimes, respectively. The entire dataset was then leveraged for the calibration of a data-driven RANS (DDRANS) solver for prediction of wind turbine wakes and power production. The DDRANS is based on a parabolic formulation of the Navier-Stokes equations with axisymmetry and boundary layer approximations, which allow achieving very low computational costs. Accuracy in prediction of wind turbine wakes and power production is achieved through an optimal tuning of the turbulence closure model. The latter is based on a mixing length model, which was developed based on previous wind turbine wake studies carried out through large eddy simulations and wind tunnel experiments. Several operative conditions of the wind farm under examination were reproduced through DDRANS for different stability regimes, wind directions and wind velocity. The results show that DDRANS is capable of achieving a good level of accuracy in prediction

  8. Relay testing at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.; Hofmayer, C.

    1989-01-01

    Brookhaven National Laboratory (BNL) is conducting a seismic test program on relays. The purpose of the test program is to investigate the influence of various designs, electrical and vibration parameters on the seismic capacity levels. The first series of testing has been completed and performed at Wyle Laboratories. The major part of the test program consisted of single axis, single frequency sine dwell tests. Random multiaxis, multifrequency tests were also performed. Highlights of the test results as well as a description of the testing methods are presented in this paper. 10 figs

  9. Mathematical Reasoning Requirements in Swedish National Physics Tests

    Science.gov (United States)

    Johansson, Helena

    2016-01-01

    This paper focuses on one aspect of mathematical competence, namely mathematical reasoning, and how this competency influences students' knowing of physics. This influence was studied by analysing the mathematical reasoning requirements upper secondary students meet when solving tasks in national physics tests. National tests are constructed to…

  10. HIV testing in dermatology - a national audit.

    Science.gov (United States)

    Esson, Gavin A; Holme, S A

    2018-05-01

    Forty percent of individuals have late-stage HIV at the time of diagnosis, resulting in increased morbidity. Identifying key diseases which may indicate HIV infection can prompt clinicians to trigger testing, which may result in more timely diagnosis. The British HIV Association has published guidelines on such indicator diseases in dermatology. We audited the practice of HIV testing in UK dermatologists and General Practitioners (GPs) and compared results with the national guidelines. This audit showed that HIV testing in key indicator diseases remains below the standard set out by the national guidelines, and that GPs with special interest in dermatology have a lower likelihood for testing, and lower confidence when compared to consultants, registrars and associate specialists. Large proportions of respondents believed further training in HIV testing would be beneficial.

  11. Crush Testing at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Feldman, Matthew R.

    2011-01-01

    The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type package designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.

  12. Advanced Test Reactor National Scientific User Facility

    International Nuclear Information System (INIS)

    Marshall, Frances M.; Benson, Jeff; Thelen, Mary Catherine

    2011-01-01

    The Advanced Test Reactor (ATR), at the Idaho National Laboratory (INL), is a large test reactor for providing the capability for studying the effects of intense neutron and gamma radiation on reactor materials and fuels. The ATR is a pressurized, light-water, high flux test reactor with a maximum operating power of 250 MWth. The INL also has several hot cells and other laboratories in which irradiated material can be examined to study material irradiation effects. In 2007 the US Department of Energy (DOE) designated the ATR as a National Scientific User Facility (NSUF) to facilitate greater access to the ATR and the associated INL laboratories for material testing research by a broader user community. This paper highlights the ATR NSUF research program and the associated educational initiatives.

  13. Advanced Test Reactor National Scientific User Facility

    Energy Technology Data Exchange (ETDEWEB)

    Frances M. Marshall; Jeff Benson; Mary Catherine Thelen

    2011-08-01

    The Advanced Test Reactor (ATR), at the Idaho National Laboratory (INL), is a large test reactor for providing the capability for studying the effects of intense neutron and gamma radiation on reactor materials and fuels. The ATR is a pressurized, light-water, high flux test reactor with a maximum operating power of 250 MWth. The INL also has several hot cells and other laboratories in which irradiated material can be examined to study material irradiation effects. In 2007 the US Department of Energy (DOE) designated the ATR as a National Scientific User Facility (NSUF) to facilitate greater access to the ATR and the associated INL laboratories for material testing research by a broader user community. This paper highlights the ATR NSUF research program and the associated educational initiatives.

  14. Development of new process network for gas chromatograph and analyzers connected with SCADA system and Digital Control Computers at Cernavoda NPP Unit 1

    International Nuclear Information System (INIS)

    Deneanu, Cornel; Popa Nemoiu, Dragos; Nica, Dana; Bucur, Cosmin

    2007-01-01

    The continuous monitoring of gas mixture concentrations (deuterium/ hydrogen/oxygen/nitrogen) accumulated in 'Moderator Cover Gas', 'Liquid Control Zone' and 'Heat Transport D 2 O Storage Tank Cover Gas', as well as the continuous monitoring of Heavy Water into Light Water concentration in 'Boilers Steam', 'Boilers Blown Down', 'Moderator heat exchangers', and 'Recirculated Water System', sensing any leaks of Cernavoda NPP U1 led to requirement of developing a new process network for gas chromatograph and analyzers connected to the SCADA system and Digital Control Computers of Cernavoda NPP Unit 1. In 2005 it was designed and implemented the process network for gas chromatograph which connected the gas chromatograph equipment to the SCADA system and Digital Control Computers of the Cernavoda NPP Unit 1. Later this process network for gas chromatograph has been extended to connect the AE13 and AE14 Fourier Transform Infrared (FTIR) analyzers with either. The Gas Chromatograph equipment measures with best accuracy the mixture gases (deuterium/ hydrogen/oxygen/nitrogen) concentration. The Fourier Transform Infrared (FTIR) AE13 and AE14 Analyzers measure the Heavy Water into Light Water concentration in Boilers Steam, Boilers BlownDown, Moderator heat exchangers, and Recirculated Water System, monitoring and signaling any leaks. The Gas Chromatograph equipment and Fourier Transform Infrared (FTIR) AE13 and AE14 Analyzers use the new OPC (Object Link Embedded for Process Control) technologies available in ABB's VistaNet network for interoperability with automation equipment. This new process network has interconnected the ABB chromatograph and Fourier Transform Infrared analyzers with plant Digital Control Computers using new technology. The result was an increased reliability and capability for inspection and improved system safety

  15. A Mixed WLS Power System State Estimation Method Integrating a Wide-Area Measurement System and SCADA Technology

    Directory of Open Access Journals (Sweden)

    Tao Jin

    2018-02-01

    Full Text Available To address the issue that the phasor measurement units (PMUs of wide area measurement system (WAMS are not sufficient for static state estimation in most existing power systems, this paper proposes a mixed power system weighted least squares (WLS state estimation method integrating a wide-area measurement system and supervisory control and data acquisition (SCADA technology. The hybrid calculation model is established by incorporating phasor measurements (including the node voltage phasors and branch current phasors and the results of the traditional state estimator in a post-processing estimator. The performance assessment is discussed through setting up mathematical models of the distribution network. Based on PMU placement optimization and bias analysis, the effectiveness of the proposed method was proved to be accurate and reliable by simulations of different cases. Furthermore, emulating calculation shows this method greatly improves the accuracy and stability of the state estimation solution, compared with the traditional WLS state estimation.

  16. Metric Indices for Performance Evaluation of a Mixed Measurement based State Estimator

    Directory of Open Access Journals (Sweden)

    Paula Sofia Vide

    2013-01-01

    Full Text Available With the development of synchronized phasor measurement technology in recent years, it gains great interest the use of PMU measurements to improve state estimation performances due to their synchronized characteristics and high data transmission speed. The ability of the Phasor Measurement Units (PMU to directly measure the system state is a key over SCADA measurement system. PMU measurements are superior to the conventional SCADA measurements in terms of resolution and accuracy. Since the majority of measurements in existing estimators are from conventional SCADA measurement system, it is hard to be fully replaced by PMUs in the near future so state estimators including both phasor and conventional SCADA measurements are being considered. In this paper, a mixed measurement (SCADA and PMU measurements state estimator is proposed. Several useful measures for evaluating various aspects of the performance of the mixed measurement state estimator are proposed and explained. State Estimator validity, performance and characteristics of the results on IEEE 14 bus test system and IEEE 30 bus test system are presented.

  17. Recent package testing successes at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Ludwig, S.B.; Singley, P.T.; Michelhaugh, R.D.; Hawk, M.B.; Shappert, L.B.

    2004-01-01

    Oak Ridge National Laboratory (ORNL)'s history of testing of radioactive material packages dates back to the early 1960s, and includes the testing of hundreds of different packages of all shapes and sizes. This paper provides an overview of ORNL's new Packaging Research Facility (PRF) at the National Transportation Research Center (NTRC), and describes recent package testing successes conducted at the NTRC from September 2002 to September 2003

  18. High Test Scores: The Wrong Road to National Economic Success

    Science.gov (United States)

    Baker, Keith

    2011-01-01

    A widely held view is that good schools are essential to a nation's international economic success and that high test scores on international tests of academic skills and knowledge indicate how good a nation's schools are. The widespread belief that good schools are an important contributor to a nation's economic success in the world is supported…

  19. Diseño e implementación de un sistema SCADA en un biorreactor para la incubación de plaguicidas en la empresa palmar del rio, NEGCORPBIS S.A.

    OpenAIRE

    Barragán Delgado, Santiago Xavier; Torres Andrade, José Luis

    2016-01-01

    This project is a SCADA system whose aim is the control and monitoring from a master station that allows viewing through a man - machine interface (HMI) created using the LabVIEW software, the status of the variables of temperature, level, oxygen and pH by using sensors placed in the bioreactor. The HMI interface is made in LabVIEW software includes the same symbols and mimic diagrams tank bioreactor, alarm generation, database and historical generation. The proposed methodo...

  20. Supervision software for string 2 magnet test facility of large hadron collider project

    International Nuclear Information System (INIS)

    Mayya, Y.S.; Sanadhya, Vivek; Lal, Pradeep; Goel, Vijay; Mukhopadhyay, S.; Saha, Shilpi

    2001-01-01

    The Supervisory Control and Data Acquisition (SCADA) software for the String 2 test facility at CERN, Geneva is developed by BARC under the framework of CERN-DAE collaboration for LHC. The supervision application is developed using PCVue32 SCADA/MMI software. The String 2 test facility prototypes one full cell of LHC and is aimed at studying and validating the individual and collective behaviour of the superconducting magnets, before installing in the tunnel. The software integrates monitoring and supervisory control of all the main subsystems of String 2 such as Cryogenics, Vacuum, Power converters, Magnet protection, Energy extraction and interlock systems. It incorporates animated process synoptics, loop and equipment control panels, configurable trend windows for real-time and historical trending of process parameters, user settability for interlock and alarm thresholds, logging of process events, equipment faults and operator activity. The plant equipment are controlled by a variety of field located Programmable Logic Controllers and VME crates which communicate process IO to the central IO server using both vendor specific and custom protocols. The system leverages OPC (OLE for Process Controls) technology for realising a generic IO server. A large number of geographically distributed client stations are arranged to provide the process specific operator interface and these are connected to the Main IO server over CERN wide intranet and internet. (author)

  1. Framework for a National Testing and Evaluation Program ...

    Science.gov (United States)

    Abstract:The National STEPP Program seeks to improve water quality by accelerating the effective implementation and adoption of innovative stormwater management technologies. Itwill attempt to accomplish this by establishing practices through highly reliable, and cost-effective Stormwater control measures (SCM) testing, evaluation, and verification services. The program will aim to remove barriers to innovation, minimize duplicative performance evaluation needs, increase confidence that regulatory requirements are met by creating consistency among testing and evaluation protocols, and establishing equity between public domain and proprietary SCM evaluation approaches.The Environmental Technology Verification Program, established by the U.S. Environmental Protection Agency (EPA) 18 years ago, was the only national program of its kindin the stormwater sector, but is now defunct, leaving a national leadership void. The STEPP initiative was triggered in part by regulatory demands in the government and private sectors to fill this vacuum. A concerted focus and study of this matter led to the release of a Water Environment Federation (WEF) white paper entitled “Investigation into the Feasibility of a National Testing and Evaluation Program for Stormwater Products and Practices” in February 2014. During this second phase of the STEPP initiative, and with EPA support, five analogous technology evaluation programs related to both stormwater and non-stormwater were an

  2. Radiographic testing at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Bossi, R.H.

    1982-01-01

    Radiographic testing is a nondestructive inspection technique which uses penetrating radiation. The Nondestructive Evaluation (NDE) Section at Lawrence Livermore National Laboratory has a broad spectrum of equipment and techniques for radiographic testing. These resources include low-energy vacuum systems, low- and mid-energy cabinet and cell radiographic systems, high-energy linear accelerators, portable x-ray machines and radioisotopes for radiographic inspections. For diagnostic testing the NDE Section also has real-time and flash radiographic equipment

  3. National HIV Testing Day at CDC-funded HIV counseling, testing, and referral sites--United States, 1994-1998.

    Science.gov (United States)

    2000-06-23

    CDC-funded human immunodeficiency virus (HIV) counseling, testing, and referral sites are an integral part of national HIV prevention efforts (1). Voluntary counseling, testing, and referral opportunities are offered to persons at risk for HIV infection at approximately 11,000 sites, including dedicated HIV counseling and testing sites, sexually transmitted disease (STD) clinics, drug-treatment centers, hospitals, and prisons. Services also are offered to women in family planning and prenatal/obstetric clinics to increase HIV prevention efforts among women and decrease the risk for perinatal HIV transmission. To increase use of HIV counseling, testing, and referral services by those at risk for HIV infection, in 1995, the National Association of People with AIDS designated June 27 each year as National HIV Testing Day. This report compares use of CDC-funded counseling, testing, and referral services the week before and the week of June 27 from 1994 through 1998 and documents the importance of a national public health campaign designed to increase knowledge of HIV serostatus.

  4. Assessing Mathematical Competencies: An Analysis of Swedish National Mathematics Tests

    Science.gov (United States)

    Boesen, Jesper; Lithner, Johan; Palm, Torulf

    2018-01-01

    Internationally, education reform has been directed towards describing educational goals that go beyond topic and content descriptions. The idea of mathematical competencies describes such goals. National tests have been seen as one way of communicating these goals and influence teaching. The present study analyses Swedish national tests in…

  5. Water Wells Monitoring Using SCADA System for Water Supply Network, Case Study: Water Treatment Plant Urseni, Timis County, Romania

    Science.gov (United States)

    Adrian-Lucian, Cococeanu; Ioana-Alina, Cretan; Ivona, Cojocinescu Mihaela; Teodor Eugen, Man; Narcis, Pelea George

    2017-10-01

    The water supply system in Timisoara Municipality is insured with about 25-30 % of the water demand from wells. The underground water headed to the water treatment plant in order to ensure equal distribution and pressure to consumers. The treatment plants used are Urseni and Ronaţ, near Timisoara, in Timis County. In Timisoara groundwater represents an alternative source for water supply and complementary to the surface water source. The present paper presents a case study with proposal and solutions for rehabilitation /equipment /modernization/ automation of water drilling in order to ensure that the entire system can be monitored and controlled remotely through SCADA (Supervisory control and data acquisition) system. The data collected from the field are designed for online efficiency monitoring regarding the energy consumption and water flow intake, performance indicators such as specific energy consumption KW/m3 and also in order to create a hydraulically system of the operating area to track the behavior of aquifers in time regarding the quality and quantity aspects.

  6. Advanced Test Reactor National Scientific User Facility Partnerships

    International Nuclear Information System (INIS)

    Marshall, Frances M.; Allen, Todd R.; Benson, Jeff B.; Cole, James I.; Thelen, Mary Catherine

    2012-01-01

    In 2007, the United States Department of Energy designated the Advanced Test Reactor (ATR), located at Idaho National Laboratory, as a National Scientific User Facility (NSUF). This designation made test space within the ATR and post-irradiation examination (PIE) equipment at INL available for use by researchers via a proposal and peer review process. The goal of the ATR NSUF is to provide researchers with the best ideas access to the most advanced test capability, regardless of the proposer's physical location. Since 2007, the ATR NSUF has expanded its available reactor test space, and obtained access to additional PIE equipment. Recognizing that INL may not have all the desired PIE equipment, or that some equipment may become oversubscribed, the ATR NSUF established a Partnership Program. This program enables and facilitates user access to several university and national laboratories. So far, seven universities and one national laboratory have been added to the ATR NSUF with capability that includes reactor-testing space, PIE equipment, and ion beam irradiation facilities. With the addition of these universities, irradiation can occur in multiple reactors and post-irradiation exams can be performed at multiple universities. In each case, the choice of facilities is based on the user's technical needs. Universities and laboratories included in the ATR NSUF partnership program are as follows: (1) Nuclear Services Laboratories at North Carolina State University; (2) PULSTAR Reactor Facility at North Carolina State University; (3) Michigan Ion Beam Laboratory (1.7 MV Tandetron accelerator) at the University of Michigan; (4) Irradiated Materials at the University of Michigan; (5) Harry Reid Center Radiochemistry Laboratories at University of Nevada, Las Vegas; (6) Characterization Laboratory for Irradiated Materials at the University of Wisconsin-Madison; (7) Tandem Accelerator Ion Beam. (1.7 MV terminal voltage tandem ion accelerator) at the University of Wisconsin

  7. National Ignition Facility TestController for automated and manual testing

    Energy Technology Data Exchange (ETDEWEB)

    Zielinski, Jason, E-mail: fishler2@llnl.gov [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States)

    2012-12-15

    The Controls and Information Systems (CIS) organization for the National Ignition Facility (NIF) has developed controls, configuration and analysis software applications that combine for several million lines of code. The team delivers updates throughout the year, from major releases containing hundreds of changes to patch releases containing a small number of focused updates. To ensure the quality of each delivery, manual and automated tests are performed using the NIF TestController test infrastructure. The TestController system provides test inventory management, test planning, automated and manual test execution, release testing summaries and results search, all through a web browser interface. As part of the three-stage software testing strategy, the NIF TestController system helps plan, evaluate and track the readiness of each release to the NIF production environment. After several years of use in testing NIF software applications, the TestController's manual testing features have been leveraged for verifying the installation and operation of NIF Target Diagnostic hardware. The TestController recorded its first test results in 2004. Today, the system has recorded the execution of more than 160,000 tests and continues to play a central role in ensuring that NIF hardware and software meet the requirements of a high reliability facility. This paper describes the TestController system and discusses its use in assuring the quality of software delivered to the NIF.

  8. National Ignition Facility TestController for automated and manual testing

    International Nuclear Information System (INIS)

    Zielinski, Jason

    2012-01-01

    The Controls and Information Systems (CIS) organization for the National Ignition Facility (NIF) has developed controls, configuration and analysis software applications that combine for several million lines of code. The team delivers updates throughout the year, from major releases containing hundreds of changes to patch releases containing a small number of focused updates. To ensure the quality of each delivery, manual and automated tests are performed using the NIF TestController test infrastructure. The TestController system provides test inventory management, test planning, automated and manual test execution, release testing summaries and results search, all through a web browser interface. As part of the three-stage software testing strategy, the NIF TestController system helps plan, evaluate and track the readiness of each release to the NIF production environment. After several years of use in testing NIF software applications, the TestController's manual testing features have been leveraged for verifying the installation and operation of NIF Target Diagnostic hardware. The TestController recorded its first test results in 2004. Today, the system has recorded the execution of more than 160,000 tests and continues to play a central role in ensuring that NIF hardware and software meet the requirements of a high reliability facility. This paper describes the TestController system and discusses its use in assuring the quality of software delivered to the NIF.

  9. A Robust WLS Power System State Estimation Method Integrating a Wide-Area Measurement System and SCADA Technology

    Directory of Open Access Journals (Sweden)

    Tao Jin

    2015-04-01

    Full Text Available With the development of modern society, the scale of the power system is rapidly increased accordingly, and the framework and mode of running of power systems are trending towards more complexity. It is nowadays much more important for the dispatchers to know exactly the state parameters of the power network through state estimation. This paper proposes a robust power system WLS state estimation method integrating a wide-area measurement system (WAMS and SCADA technology, incorporating phasor measurements and the results of the traditional state estimator in a post-processing estimator, which greatly reduces the scale of the non-linear estimation problem as well as the number of iterations and the processing time per iteration. This paper firstly analyzes the wide-area state estimation model in detail, then according to the issue that least squares does not account for bad data and outliers, the paper proposes a robust weighted least squares (WLS method that combines a robust estimation principle with least squares by equivalent weight. The performance assessment is discussed through setting up mathematical models of the distribution network. The effectiveness of the proposed method was proved to be accurate and reliable by simulations and experiments.

  10. Can trained lay providers perform HIV testing services? A review of national HIV testing policies.

    Science.gov (United States)

    Flynn, David E; Johnson, Cheryl; Sands, Anita; Wong, Vincent; Figueroa, Carmen; Baggaley, Rachel

    2017-01-04

    Only an estimated 54% of people living with HIV are aware of their status. Despite progress scaling up HIV testing services (HTS), a testing gap remains. Delivery of HTS by lay providers may help close this testing gap, while also increasing uptake and acceptability of HIV testing among key populations and other priority groups. 50 National HIV testing policies were collated from WHO country intelligence databases, contacts and testing program websites. Data regarding lay provider use for HTS was extracted and collated. Our search had no geographical or language restrictions. This data was then compared with reported data from the Global AIDS Response Progress Reporting (GARPR) from July 2015. Forty-two percent of countries permit lay providers to perform HIV testing and 56% permit lay providers to administer pre-and post-test counseling. Comparative analysis with GARPR found that less than half (46%) of reported data from countries were consistent with their corresponding national HIV testing policy. Given the low uptake of lay provider use globally and their proven use in increasing HIV testing, countries should consider revising policies to support lay provider testing using rapid diagnostic tests.

  11. Supervisory Control and Data Acquisition Laboratory

    Directory of Open Access Journals (Sweden)

    M. Iacob

    2010-06-01

    Full Text Available This paper presents practical laboratories for teaching purpose in Supervisory Control and Data Acquisition (SCADA systems. A SCADA system is described in terms of architecture, process interfaces, functionality, and application development facilities. These concepts are implemented on an integrated automation system, particularly for digital control of electric drives with a distributed peripheral, i.e., Totally Integrated Automation with Democase from Siemens. Using this system, a wide range of applications can be designed, implemented and tested. A practical labs set is presented to introduce gradually the main SCADA elements, and finally to develop an application to control an induction motor in interlocked manual/automatic mode, with touch-screen Human Machine Interface (HMI. The system employs industrial busses like PROFIBus and industrial Ethernet. The SCADA system also shows trends, alarms, motor frequency and automatic sequence of motor speed profile.

  12. Spectrum Management Guidelines for National and Service Test and Training Ranges

    Science.gov (United States)

    2017-07-12

    Frequency Management Group RCC 700-17 SPECTRUM MANAGEMENT GUIDELINES FOR NATIONAL AND SERVICE TEST AND TRAINING RANGES DISTRIBUTION...left blank. DOCUMENT 700-01 SPECTRUM MANAGEMENT GUIDELINES FOR NATIONAL AND SERVICE TEST AND TRAINING RANGES July 2017...Prepared by RANGE COMMANDERS COUNCIL FREQUENCY MANAGEMENT GROUP Published by Secretariat Range Commanders Council U.S. Army White

  13. 78 FR 7460 - Stakeholder Meeting on the Nationally Recognized Testing Laboratory Program

    Science.gov (United States)

    2013-02-01

    ...] Stakeholder Meeting on the Nationally Recognized Testing Laboratory Program AGENCY: Occupational Safety and Health Administration (OSHA), Labor. ACTION: Notice of stakeholder meeting. SUMMARY: OSHA invites interested parties to attend an informal stakeholder meeting concerning Nationally Recognized Testing...

  14. Evaluation of nine HIV rapid test kits to develop a national HIV testing algorithm in Nigeria

    Directory of Open Access Journals (Sweden)

    Orji Bassey

    2015-05-01

    Full Text Available Background: Non-cold chain-dependent HIV rapid testing has been adopted in many resource-constrained nations as a strategy for reaching out to populations. HIV rapid test kits (RTKs have the advantage of ease of use, low operational cost and short turnaround times. Before 2005, different RTKs had been used in Nigeria without formal evaluation. Between 2005 and 2007, a study was conducted to formally evaluate a number of RTKs and construct HIV testing algorithms. Objectives: The objectives of this study were to assess and select HIV RTKs and develop national testing algorithms. Method: Nine RTKs were evaluated using 528 well-characterised plasma samples. These comprised 198 HIV-positive specimens (37.5% and 330 HIV-negative specimens (62.5%, collected nationally. Sensitivity and specificity were calculated with 95% confidence intervals for all nine RTKs singly and for serial and parallel combinations of six RTKs; and relative costs were estimated. Results: Six of the nine RTKs met the selection criteria, including minimum sensitivity and specificity (both ≥ 99.0% requirements. There were no significant differences in sensitivities or specificities of RTKs in the serial and parallel algorithms, but the cost of RTKs in parallel algorithms was twice that in serial algorithms. Consequently, three serial algorithms, comprising four test kits (BundiTM, DetermineTM, Stat-Pak® and Uni-GoldTM with 100.0% sensitivity and 99.1% – 100.0% specificity, were recommended and adopted as national interim testing algorithms in 2007. Conclusion: This evaluation provides the first evidence for reliable combinations of RTKs for HIV testing in Nigeria. However, these RTKs need further evaluation in the field (Phase II to re-validate their performance.

  15. Integrating a work-flow engine within a commercial SCADA to build end users applications in a scientific environment

    International Nuclear Information System (INIS)

    Ounsy, M.; Pierre-Joseph Zephir, S.; Saintin, K.; Abeille, G.; Ley, E. de

    2012-01-01

    To build integrated high-level applications, SOLEIL is using an original component-oriented approach based on GlobalSCREEN, an industrial Java SCADA. The aim of this integrated development environment is to give SOLEIL's scientific and technical staff a way to develop GUI (Graphical User Interface) applications for external users of beamlines. These GUI applications must address the two following needs: monitoring and supervision of a control system and development and execution of automated processes (as beamline alignment, data collection and on-line data analysis). The first need is now completely answered through a rich set of Java graphical components based on the COMETE library and providing a high level of service for data logging, scanning and so on. To reach the same quality of service for process automation, a big effort has been made for more seamless integration of PASSERELLE, a work-flow engine with dedicated user-friendly interfaces for end users, packaged as JavaBeans in GlobalSCREEN components library. Starting with brief descriptions of software architecture of the PASSERELLE and GlobalSCREEN environments, we will then present the overall system integration design as well as the current status of deployment on SOLEIL beamlines. (authors)

  16. Quantifying the Impact of Unavailability in Cyber-Physical Environments

    Energy Technology Data Exchange (ETDEWEB)

    Aissa, Anis Ben [Université de Tunis El Manar, Tunisia; Abercrombie, Robert K [ORNL; Sheldon, Federick T. [University of Memphis; Mili, Ali [New Jersey Insitute of Technology

    2014-01-01

    The Supervisory Control and Data Acquisition (SCADA) system discussed in this work manages a distributed control network for the Tunisian Electric & Gas Utility. The network is dispersed over a large geographic area that monitors and controls the flow of electricity/gas from both remote and centralized locations. The availability of the SCADA system in this context is critical to ensuring the uninterrupted delivery of energy, including safety, security, continuity of operations and revenue. Such SCADA systems are the backbone of national critical cyber-physical infrastructures. Herein, we propose adapting the Mean Failure Cost (MFC) metric for quantifying the cost of unavailability. This new metric combines the classic availability formulation with MFC. The resulting metric, so-called Econometric Availability (EA), offers a computational basis to evaluate a system in terms of the gain/loss ($/hour of operation) that affects each stakeholder due to unavailability.

  17. Want Amid Plenty: Developing and Testing a Cross-National Measure of Anomie

    Directory of Open Access Journals (Sweden)

    John K. Cochran

    2008-11-01

    Full Text Available One of the biggest challenges facing researchers trying to empirically test structural or institutional anomie theories is the operationalization of the key concept of anomie. This challenge is heightened by the data constraints involved in cross-national research. As a result, researchers have been forced to rely on surrogate or proxy measures of anomie and indirect tests of the theories. The purpose of this study is to examine an innovative and more theoretically sound measure of anomie and to test its ability to make cross-national predictions of serious crime. Our results are supportive of the efficacy of this construct to explain cross-national variations in crime rates. Nations with the highest rates of structural anomie also have the highest predicted rates of homicide.

  18. Switch evaluation test system for the National Ignition Facility

    International Nuclear Information System (INIS)

    Savage, M.E.; Simpson, W.W.; Reynolds, F.D.

    1997-01-01

    Flashlamp pumped lasers use pulsed power switches to commute energy stored in capacitor banks to the flashlamps. The particular application in which the authors are interested is the National Ignition Facility (NIF), being designed by Lawrence Livermore National Laboratory, Los Alamos National Laboratory, and Sandia National Laboratories (SNL). To lower the total cost of these switches, SNL has a research program to evaluate large closing switches. The target value of the energy switched by a single device is 1.6 MJ, from a 6 mF, 24kV capacitor bank. The peak current is 500 kA. The lifetime of the NIF facility is 24,000 shots. There is no switch today proven at these parameters. Several short-lived switches (100's of shots) exist that can handle the voltage and current, but would require maintenance during the facility life. Other type devices, notably ignitrons, have published lifetimes in excess of 20,000 shots, but at lower currents and shorter pulse widths. The goal of the experiments at SNL is to test switches with the full NIF wave shape, and at the correct voltage. The SNL facility can provide over 500 kA at 24 kV charge voltage. the facility has 6.4 mF total capacitance, arranged in 25 sub-modules. the modular design makes the facility more flexible (for possible testing at lower current) and safer. For pulse shaping (the NIF wave shape is critically damped) there is an inductor and resistor for each of the 25 modules. Rather than one large inductor and resistor, this lowers the current in the pulse shaping components, and raises their value to those more easily attained with lumped inductors and resistors. The authors show the design of the facility, and show results from testing conducted thus far. They also show details of the testing plan for high current switches

  19. Field test of a leak detection system: planning, execution and results

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio da Silva; Daniel; Melo Filho, Silvio A.; Niehues de Farias, Mauro; Pacheco, Anderson [Petrobas Transporte SA - TRANSPETRO, (Brazil)

    2010-07-01

    The OLAPA pipeline (Brazil) with its 97.6 km in length crosses difficult environment with a combination of mountain and dense forest. The non-detection of leaks in this kind of pipeline would have serious consequences. This pipeline was chosen for testing the performance of a new TRANSPETRO leak detection system. This paper reports the testing process of the new leakage detection method carried out on the OLAPA pipeline. TRANSPETRO decided to test the leakwarn system which is a computational pipeline monitoring (CPM) method which and can be integrated into their SCADA system. The CPM uses the mass balance principle with line pack change to analyze the pipeline operational parameters. The tests consisted of comparing the theoretical results with in-field results of alarm times obtained from controlled removal of product, simulating a real leak. Three leaks were tested in different states of operation and size of leak. It was found that the results were compatible with the expected alarm time.

  20. Status and update of the National Ignition Facility radiation effects testing program

    International Nuclear Information System (INIS)

    Davis, J F; Serduke, F J; Wuest, C R.

    1998-01-01

    We are progressing in our efforts to make the National Ignition Facility (NIF) available to the nation as a radiation effects simulator to support the Services needs for nuclear hardness and survivability testing and validation. Details of our program were summarized in a paper presented at the 1998 HEART Conference [1]. This paper describes recent activities and updates plans for NIF radiation effects testing. research. Radiation Effects Testing

  1. 78 FR 53466 - Modification of Two National Customs Automation Program (NCAP) Tests Concerning Automated...

    Science.gov (United States)

    2013-08-29

    ... Customs Automation Program (NCAP) Tests Concerning Automated Commercial Environment (ACE) Document Image... National Customs Automation Program (NCAP) tests concerning document imaging, known as the Document Image... the National Customs Automation Program (NCAP) tests concerning document imaging, known as the...

  2. Autonomic computing meets SCADA security

    OpenAIRE

    Nazir, S; Patel, S; Patel, D

    2017-01-01

    © 2017 IEEE. National assets such as transportation networks, large manufacturing, business and health facilities, power generation, and distribution networks are critical infrastructures. The cyber threats to these infrastructures have increasingly become more sophisticated, extensive and numerous. Cyber security conventional measures have proved useful in the past but increasing sophistication of attacks dictates the need for newer measures. The autonomic computing paradigm mimics the auton...

  3. Evaluation of power control concepts using the PMAD systems test bed. [Power Management and Distribution

    Science.gov (United States)

    Beach, R. F.; Kimnach, G. L.; Jett, T. A.; Trash, L. M.

    1989-01-01

    The Lewis Research Center's Power Management and Distribution (PMAD) System testbed and its use in the evaluation of control concepts applicable to the NASA Space Station Freedom electric power system (EPS) are described. The facility was constructed to allow testing of control hardware and software in an environment functionally similar to the space station electric power system. Control hardware and software have been developed to allow operation of the testbed power system in a manner similar to a supervisory control and data acquisition (SCADA) system employed by utility power systems for control. The system hardware and software are described.

  4. OPSAID Initial Design and Testing Report.

    Energy Technology Data Exchange (ETDEWEB)

    Hurd, Steven A.; Stamp, Jason Edwin [Sandia National Laboratories, Albuquerque, NM; Chavez, Adrian R. [Sandia National Laboratories, Albuquerque, NM

    2007-11-01

    Process Control System (PCS) security is critical to our national security. Yet, there are a number of technological, economic, and educational impediments to PCS owners implementing effective security on their systems. OPSAID (Open PCS Security Architecture for Interoperable Design), a project sponsored by the US Department of Energy's Office of Electricity Delivery and Reliability, aims to address this issue through developing and testing an open source architecture for PCS security. Sandia National Laboratories, along with a team of PCS vendors and owners, have developed and tested this PCS security architecture. This report describes their progress to date.2 AcknowledgementsThe authors acknowledge and thank their colleagues for their assistance with the OPSAID project.Sandia National Laboratories: Alex Berry, Charles Perine, Regis Cassidy, Bryan Richardson, Laurence PhillipsTeumim Technical, LLC: Dave TeumimIn addition, the authors are greatly indebted to the invaluable help of the members of the OPSAID Core Team. Their assistance has been critical to the success and industry acceptance of the OPSAID project.Schweitzer Engineering Laboratory: Rhett Smith, Ryan Bradetich, Dennis GammelTelTone: Ori Artman Entergy: Dave Norton, Leonard Chamberlin, Mark AllenThe authors would like to acknowledge that the work that produced the results presented in this paper was funded by the U.S. Department of Energy/Office of Electricity Delivery and Energy Reliability (DOE/OE) as part of the National SCADA Test Bed (NSTB) Program. Executive SummaryProcess control systems (PCS) are very important for critical infrastructure and manufacturing operations, yet cyber security technology in PCS is generally poor. The OPSAID (Open PCS (Process Control System) Security Architecture for Interoperable Design) program is intended to address these security shortcomings by accelerating the availability and deployment of comprehensive security technology for PCS, both for existing PCS

  5. Heterogeneity in testing practices for infections during pregnancy: national survey across Switzerland.

    Science.gov (United States)

    Aebi-Popp, Karoline; Kahlert, Christian; Rauch, Andri; Mosimann, Beatrice; Baud, David; Low, Nicola; Surbek, Daniel

    2016-01-01

    Detection and treatment of infections during pregnancy are important for both maternal and child health. The objective of this study was to describe testing practices and adherence to current national guidelines in Switzerland. We invited all registered practicing obstetricians and gynaecologists in Switzerland to complete an anonymous web-based questionnaire about strategies for testing for 14 infections during pregnancy. We conducted a descriptive analysis according to demographic characteristics. Of 1138 invited clinicians, 537 (47.2%) responded and 520 (45.6%) were eligible as they are currently caring for pregnant women. Nearly all eligible respondents tested all pregnant women for group B streptococcus (98.0%), hepatitis B virus (HBV) (96.5%) and human immunodeficiency virus (HIV) (94.7%), in accordance with national guidelines. Although testing for toxoplasmosis is not recommended, 24.1% of respondents tested all women and 32.9% tested at the request of the patient. Hospital doctors were more likely not to test for toxoplasmosis than doctors working in private practice (odds ratio [OR] 2.52, 95% confidence interval [CI] 1.04-6.13, p = 0.04). Only 80.4% of respondents tested all women for syphilis. There were regional differences in testing for some infections. The proportion of clinicians testing all women for HIV, HBV and syphilis was lower in Eastern Switzerland and the Zurich region (69.4% and 61.2%, respectively) than in other regions (range 77.1-88.1%, p Switzerland. More extensive national guidelines could improve consistency of testing practices.

  6. Design for the National RF Test Facility at ORNL

    International Nuclear Information System (INIS)

    Gardner, W.L.; Hoffman, D.J.; Becraft, W.R.

    1983-01-01

    Conceptual and preliminary engineering design for the National RF Test Facility at Oak Ridge National Laboratory (ORNL) has been completed. The facility will comprise a single mirror configuration embodying two superconducting development coils from the ELMO Bumpy Torus Proof-of-Principle (EBT-P) program on either side of a cavity designed for full-scale antenna testing. The coils are capable of generating a 1.2-T field at the axial midpoint between the coils separated by 1.0 m. The vacuum vessel will be a stainless steel, water-cooled structure having an 85-cm-radius central cavity. The facility will have the use of a number of continuous wave (cw), radio-frequency (rf) sources at levels including 600 kW at 80 MHz and 100 kW at 28 GHz. Several plasma sources will provide a wide range of plasma environments, including densities as high as approx. 5 x 10 13 cm -3 and temperatures on the order of approx. 10 eV. Furthermore, a wide range of diagnostics will be available to the experimenter for accurate appraisal of rf testing

  7. Accreditation of testing laboratories in CNEA (National Atomic Energy Commission)

    International Nuclear Information System (INIS)

    Piacquadio, N.H.; Casa, V.A.; Palacios, T.A.

    1993-01-01

    The recognition of the technical capability of a testing laboratory is carried out by Laboratory Accreditation Bodies as the result of a satisfactory evaluation and the systematic follow up of the certified qualification. In Argentina the creation of a National Center for the Accreditation of Testing Laboratories, as a first step to assess a National Accreditation System is currently projected. CNEA, as an institution involved in technological projects and in the development and production of goods and services, has adopted since a long time ago quality assurance criteria. One of their requirements is the qualification of laboratories. Due to the lack of a national system, a Committee for the Qualification of Laboratories was created jointly by the Research and Development and Nuclear Fuel Cycle Areas with the responsibility of planning and management of the system evaluation and the certification of the quality of laboratories. The experience in the above mentioned topics is described in this paper. (author)

  8. The Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.

    1992-01-01

    The Brookhaven National Laboratory Accelerator Test Facility comprises a 50 MeV traveling wave electron linear accelerator utilizing a high gradient, photo-excited, raidofrequency electron gun as an injector and an experimental area for study of new acceleration methods or advanced radiation sources using free electron lasers. Early operation of the linear accelerator system including calculated and measured beam parameters are presented together with the experimental program for accelerator physics and free electron laser studies

  9. 77 FR 48527 - National Customs Automation Program (NCAP) Test Concerning Automated Commercial Environment (ACE...

    Science.gov (United States)

    2012-08-14

    ... National Customs Automation Program (NCAP) test concerning the simplified entry functionality in the... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection National Customs Automation Program (NCAP) Test Concerning Automated Commercial Environment (ACE) Simplified Entry: Modification of...

  10. Final report : impacts analysis for cyber attack on electric power systems (National SCADA Test Bed FY08).

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Laurence R.; Richardson, Bryan T.; Stamp, Jason Edwin; LaViolette, Randall A.

    2009-02-01

    To analyze the risks due to cyber attack against control systems used in the United States electrical infrastructure, new algorithms are needed to determine the possible impacts. This research is studying the Reliability Impact of Cyber ttack (RICA) in a two-pronged approach. First, malevolent cyber actions are analyzed in terms of reduced grid reliability. Second, power system impacts are investigated using an abstraction of the grid's dynamic model. This second year of esearch extends the work done during the first year.

  11. National South African HIV prevalence estimates robust despite substantial test non-participation

    Directory of Open Access Journals (Sweden)

    Guy Harling

    2017-07-01

    Full Text Available Background. South African (SA national HIV seroprevalence estimates are of crucial policy relevance in the country, and for the worldwide HIV response. However, the most recent nationally representative HIV test survey in 2012 had 22% test non-participation, leaving the potential for substantial bias in current seroprevalence estimates, even after controlling for selection on observed factors. Objective. To re-estimate national HIV prevalence in SA, controlling for bias due to selection on both observed and unobserved factors in the 2012 SA National HIV Prevalence, Incidence and Behaviour Survey. Methods. We jointly estimated regression models for consent to test and HIV status in a Heckman-type bivariate probit framework. As selection variable, we used assigned interviewer identity, a variable known to predict consent but highly unlikely to be associated with interviewees’ HIV status. From these models, we estimated the HIV status of interviewed participants who did not test. Results. Of 26 710 interviewed participants who were invited to test for HIV, 21.3% of females and 24.3% of males declined. Interviewer identity was strongly correlated with consent to test for HIV; declining a test was weakly associated with HIV serostatus. Our HIV prevalence estimates were not significantly different from those using standard methods to control for bias due to selection on observed factors: 15.1% (95% confidence interval (CI 12.1 - 18.6 v. 14.5% (95% CI 12.8 - 16.3 for 15 - 49-year-old males; 23.3% (95% CI 21.7 - 25.8 v. 23.2% (95% CI 21.3 - 25.1 for 15 - 49-year-old females. Conclusion. The most recent SA HIV prevalence estimates are robust under the strongest available test for selection bias due to missing data. Our findings support the reliability of inferences drawn from such data.

  12. 77 FR 64343 - Notice of Availability: Test Tools and Test Procedures Approved for the Office of the National...

    Science.gov (United States)

    2012-10-19

    ... Approved for the Office of the National Coordinator for Health Information Technology (ONC) HIT Certification Program AGENCY: Office of the National Coordinator for Health Information Technology, Office of... performing the testing of EHR technology under the ONC HIT Certification Program, particularly when the...

  13. National security and the comprehensive test ban treaty

    International Nuclear Information System (INIS)

    Landauer, J.K.

    1980-08-01

    For nearly three years now, the US, UK, and USSR have been working on the draft of a treaty that would ban all nuclear explosions (both peaceful applications and weapon tests) and institute verification and monitoring provisions to ensure compliance with the treaty. The status of the draft treaty is summarized. The question, Is a CTBT really in the interest of US national security. is analyzed with arguments used by both proponents and opponents of the CTBT. It is concluded that there are arguments both for and against a CTBT, but, for those whose approach to national security can be expressed as peace through preparedness, the arguments against a CTBT appear persuasive

  14. National STD Awareness Month and GYT: Get Yourself Tested PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2011-03-03

    April is National STD Awareness Month. In this PSA, native communities, especially adolescents and young adults, are encouraged to get educated, tested, and treated by visiting gytnow.org.  Created: 3/3/2011 by National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention.   Date Released: 3/3/2011.

  15. Radioactive material package testing capabilities at Sandia National Laboratories

    International Nuclear Information System (INIS)

    Uncapher, W.L.; Hohnstreiter, G.F.

    1995-01-01

    Evaluation and certification of radioactive and hazardous material transport packages can be accomplished by subjecting these packages to normal transport and hypothetical accident test conditions. The regulations allow package designers to certify packages using analysis, testing, or a combination of analysis and testing. Testing can be used to substantiate assumptions used in analytical models and to demonstrate package structural and thermal response. Regulatory test conditions include impact, puncture, crush, penetration, water spray, immersion, and thermal environments. Testing facilities are used to simulate the required test conditions and provide measurement response data. Over the past four decades, comprehensive testing facilities have been developed at Sandia National Laboratories to perform a broad range of verification and certification tests on hazardous and radioactive material packages or component sections. Sandia's facilities provide an experience base that has been established during the development and certification of many package designs. These unique facilities, along with innovative instrumentation data collection capabilities and techniques, simulate a broad range of testing environments. In certain package designs, package testing can be an economical alternative to complex analysis to resolve regulatory questions or concerns

  16. The Dental Hygiene Aptitude Tests and the American College Testing Program Tests as Predictors of Scores on the National Board Dental Hygiene Examination.

    Science.gov (United States)

    Longenbecker, Sueann; Wood, Peter H.

    1984-01-01

    Scores from the National Board Dental Hygiene Examination (NBDHE) served as the criterion variable in a comparison of the predictive validity of the Dental Hygiene Aptitude Tests (DHAT) and the ACT Assessment tests. The DHAT-Science and Verbal tests combined to produce the highest multiple correlation with NBDHE scores. (Author/DWH)

  17. Upgrading the data acquisition and control systems of the European Breeding Blanket Test Facility

    International Nuclear Information System (INIS)

    Mannori, Simone; Sermenghi, Valerio; Utili, Marco; Malavasi, Andrea; Gianotti, Daniel

    2013-01-01

    Highlights: • Data Acquisition and Control Systems (DACS) upgrading of experimental plant for full size thermo hydraulic testing of nuclear subsystems. • DACS development using integrated hardware/software platform with graphical programming (LabVIEW). • Development of simplified models for real-time simulation. • Rapid prototyping with real time simulation of the complete plant. • Using the code developed for the real time simulator for the real plant DACS. -- Abstract: The EBBTF (European Breeding Blanket Test Facility) experimental plant is a key component for the development of the breeding blankets (TBMs test blanket modules, HCLL helium cooled lithium lead and HCPB helium cooled pebble bed types) used by ITER. EBBTF is an experimental plant which provides the double breeding/cooling loops (liquid metal and gas) required for HCLL testing. EBBTF is composed of four subsystems (TBM, IELLLO integrated European lead lithium loop, HE-FUS3 helium fusion loop, version 3 and helium compressor build by ATEKO) with dedicated control systems realized with hardware/software combinations covering 15 years (1995–2010) time span. At the end of 2010 we began to upgrade the HE-FUS3 data acquisition control systems (DACS) replacing the obsolete PLC Siemens S5 with National Instruments Compact FieldPoint and LabVIEW. The control room has been completely reorganized using high resolution monitors and workstations linked with standard Ethernet interfaces. The data acquisition, control, safety and SCADA software has been completely developed in ENEA using LabVIEW. In this paper we are going to discuss the technical difficulties and the solutions that we have used to accomplish the upgrade

  18. Key quality aspects for a new metallic composite pipe: corrosion testing, welding, weld inspection and manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Conder, Robert J.; Felton, Peter [Xodus Group Ltd., Aberdeen (United Kingdom); Smith, Richard [Shell Global Solutions Inc., Houston, TX (United States); Burke, Raymond [Pipestream Inc., Houston, TX (United States); Dikstra, Frits; Deleye, Xavier [Applus RTD Ltd., Rotterdam (Netherlands)

    2010-07-01

    XPipeTM is a new metallic composite pipe. This paper discusses three aspects of this new technology. The first subject is determination of the probability of hydrogen embrittlement by the XPipeTM manufacturing method. Two materials were analyzed in three tests: slow strain rate test, constant load test and notched tensile test. The results showed that the high strength steels used do not appear to be susceptible to hydrogen embrittlement. The second subject of this article is weld inspection. A non-destructive testing method of girth welds is developed to allow inspection of the thin-walled austenitic liner pipe. The results demonstrated that the welds can be inspected using the creeping wave technique. The third subject is quality control systems using the SCADA system, which maintains traceability of the materials and monitors and records all parameters during the production process. This system appears to be efficient in ensuring that the product pipe meets recognized quality standards.

  19. Accuracy in HIV Rapid Testing among Laboratory and Non-laboratory Personnel in Zambia: Observations from the National HIV Proficiency Testing System.

    Directory of Open Access Journals (Sweden)

    Sheila Mwangala

    Full Text Available Despite rapid task-shifting and scale-up of HIV testing services in high HIV prevalence countries, studies evaluating accuracy remain limited. This study aimed to assess overall accuracy level and factors associated with accuracy in HIV rapid testing in Zambia.Accuracy was investigated among rural and urban HIV testing sites participating in two annual national HIV proficiency testing (PT exercises conducted in 2009 (n = 282 sites and 2010 (n = 488 sites. Testers included lay counselors, nurses, laboratory personnel and others. PT panels of five dry tube specimens (DTS were issued to testing sites by the national reference laboratory (NRL. Site accuracy level was assessed by comparison of reported results to the expected results. Non-parametric rank tests and multiple linear regression models were used to assess variation in accuracy between PT cycles and between tester groups, and to examine factors associated with accuracy respectively.Overall accuracy level was 93.1% (95% CI: 91.2-94.9 in 2009 and 96.9% (95% CI: 96.1-97.8 in 2010. Differences in accuracy were seen between the tester groups in 2009 with laboratory personnel being more accurate than non-laboratory personnel, while in 2010 no differences were seen. In both PT exercises, lay counselors and nurses had more difficulties interpreting results, with more occurrences of false-negative, false-positive and indeterminate results. Having received the standard HIV rapid testing training and adherence to the national HIV testing algorithm were positively associated with accuracy.The study showed an improvement in tester group and overall accuracy from the first PT exercise to the next. Average number of incorrect test results per 1000 tests performed was reduced from 69 to 31. Further improvement is needed, however, and the national HIV proficiency testing system seems to be an important tool in this regard, which should be continued and needs to be urgently strengthened.

  20. 75 FR 9953 - Definition and Requirements for a Nationally Recognized Testing Laboratory (NRTL); Extension of...

    Science.gov (United States)

    2010-03-04

    ...] Definition and Requirements for a Nationally Recognized Testing Laboratory (NRTL); Extension of the Office of Management and Budget's (OMB) Approval of Information Collection (Paperwork) Requirements AGENCY... its Regulation on the Definition and Requirements for a Nationally Recognized Testing Laboratory (29...

  1. Minnesota urban partnership agreement national evaluation : exogenous factors test plan.

    Science.gov (United States)

    2009-11-17

    This report presents the exogenous factors test plan for the national evaluation of the Minnesota Urban Partnership Agreement (UPA) under the United States Department of Transportation (U.S. DOT) UPA Program. The Minnesota UPA projects focus on reduc...

  2. Impact of HPV testing, HPV vaccine development, and changing screening frequency on national Pap test volume: projections from the National Health Interview Survey (NHIS).

    Science.gov (United States)

    Eltoum, Isam A; Roberson, Janie

    2007-02-25

    The frequently cited number of 50 million annual Papanicolaou cervical screening (Pap) tests performed in the US was based on the National Health Interview Survey (NHIS) of the 1980s. Since then, monumental changes have occurred. More change will soon follow when primary human papilloma virus (HPV) testing and/or HPV vaccine delivery are fully accepted and implemented. The objectives of this study were 1) to estimate the total annual Pap tests performed in the US based on recent NHIS surveys, and 2) to estimate the potential change in the total annual Pap volume produced by changing demographics, reduced screening frequency, HPV testing, and the HPV vaccine. In the NHIS 2000 and NHIS 2005, women were asked to report the frequency of their Pap tests for the 6 years prior to the interview and to report whether they had abnormal findings. The authors analyzed the survey respondents answers to these questions by using SAS Survey Procedures (SAS Institute, NC). The results were stratified by age, and the total national volume was then extrapolated from a similarly stratified 2000 US census. The projected increase of total Pap tests for the next 25 years was determined by using the projected census data. Potential reductions of Pap tests performed secondarily to HPV testing of women >30 years old and of HPV vaccination were also determined. Based on NHIS 2000 and NHIS 2005, 66 million (95% CI, 65-68) and 65 million (95% CI, 64-67) Pap tests were performed in the US, respectively. Had HPV testing been performed in women older than 30 years who had both negative HPV and negative 3-year Pap tests, then 30% (95% CI, 29-32%) of Pap tests would not have been performed. If both HPV testing and vaccination are performed, the total number of Pap tests performed annually is predicted to be reduced by 43% (95% CI, 35-38%). Therefore, despite an expected increase in the population of women eligible for Pap tests, the total number will likely decrease substantially in the future

  3. Third Dutch Process Security Control Event

    NARCIS (Netherlands)

    Luiijf, H.A.M.

    2009-01-01

    On June 4th, 2009, the third Dutch Process Control Security Event took place in Amsterdam. The event, organised by the Dutch National Infrastructure against Cybercrime (NICC), attracted both Dutch process control experts and members of the European SCADA and Control Systems Information Exchange

  4. 78 FR 66039 - Modification of National Customs Automation Program Test Concerning Automated Commercial...

    Science.gov (United States)

    2013-11-04

    ... Customs Automation Program Test Concerning Automated Commercial Environment (ACE) Cargo Release (Formerly...) plan to both rename and modify the National Customs Automation Program (NCAP) test concerning the... data elements required to obtain release for cargo transported by air. The test will now be known as...

  5. Netherlands' National Fukushima Stress Test for the Borssele Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-12-15

    This is the National Report of the Kingdom of the Netherlands on the post-Fukushima 'stress test' of the Borssele (one unit) Nuclear Power Plant, the KCB. This report complies with the guidelines published by ENSREG (European Nuclear Safety Regulator Group) in May (objectives and scope) and October 2011 (structure of report) for National Reports. The operator of the KCB has submitted a Licensee Report to the regulatory body, that addresses all topics prescribed in the ENSREG guidelines for the 'stress test' and meets the prescribed format. The National Report presents conclusions about licensee's compliance with its design basis. The conclusions are based on the Licensee Report as well as on several decades of regulatory oversight, including regulatory inspections, evaluations of various applications for modification of the licences, regulatory control of the special Long-Term Operation programme and the various extensive Periodic Safety Reviews. The National Report presents conclusions on the safety margins identified in the Licensee Report. The National report notes the measures proposed and considered in the Licensee Report. In principle, the regulatory body can endorse various of these measures, but further assessment is needed to establish the effectiveness of these. The regulatory body proposes additional topics suitable for (more detailed) assessment.

  6. Minnesota urban partnership agreement national evaluation : transit system data test plan.

    Science.gov (United States)

    2009-11-17

    This report presents the test plan for collecting and analyzing transit system data for the Minnesota Urban Partnership Agreement (UPA) National Evaluation under the United States Department of Transportation (U.S. DOT) UPA Program. The Minnesota UPA...

  7. Willowglen Systems Inc. : 8 case studies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    The various supervisory control and data acquisition (SCADA) systems designed by Willowglen Systems Inc. were described. The company provides custom SCADA technology products, automation systems, and technical services for various applications. Their remote terminal units (RTUs) were designed to have a very low power consumption rate, and can be operated from any power source. The company has also designed integrated metering and communications solutions for remote locations. The following 8 case studies of Willowglen System solutions were highlighted: (1) a SCADA system designed for the Northwest Territories Power Corporation, (2) a system of RTUs installed at the Shell Canada Ltd. Caroline Gas Complex, (3) a SCADA system designed to monitor a natural gas pipeline, (4) a SCADA system designed to monitor a transmission pipeline and distribution system in Singapore, (5) RTUs designed to monitor gas dehydration units in Bahrain, (6) a SCADA system designed for a refined petroleum products pipeline, (7) a SCADA system installed at an electric power utility in New Brunswick, and (8) a tank gauging system designed for a large oil refinery in Alberta. 7 figs.

  8. Integrated real-time information to use in commercial, logistics and operational activities provide by the national control center operation of Transpetro

    Energy Technology Data Exchange (ETDEWEB)

    Aniceto, Hello A. R. [National Control Center Operation Transpetro, Rio de Janeiro, (Brazil)

    2010-07-01

    TRANSPETRO needed real time computational tools to manage its commercial, logistics and operational activities more efficiently. TRANSPETRO's National Control Center Operation developed an information site that provides information in real time on the process plans involved in each operation, using a Plant Information Management System (PIMS). SCADA systems were introduced during 2009 and 2010. This paper reports on the global introduction of the site and its basic architecture. Every screen displays the overall data in real time on movement in volume in pipeline operated by TRANSPETRO. The products transported are tracked for each infrastructure and are shown on dynamic geographic maps. Applications have been developed to improve the quality of information available to customers. It was found that the development of this site using PIMS technology brought gains in support to decision-making at the strategic and tactical levels for TRANSPETRO.

  9. Gifted and Talented Education: A National Test Case in Peoria.

    Science.gov (United States)

    Fetterman, David M.

    1986-01-01

    This article presents a study of a program in Peoria, Illinois, for the gifted and talented that serves as a national test case for gifted education and minority enrollment. It was concluded that referral, identification, and selection were appropriate for the program model but that inequalities resulted from socioeconomic variables. (Author/LMO)

  10. Testing of a cryogenic recooler heat exchanger at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Nicoletti, A.; Wu, K.C.

    1993-01-01

    Brookhaven National Laboratory has tested a recooler heat exchanger intended to be used in the cryogenic system of the Relativistic Heavy Ion Collider. The unit is required to transfer 225 Watts from a supercritical helium stream flowing at 100 g/s to a helium bath boiling at 4.25 K. Measurements made with heat loads of 50 to over 450 Watts on the unit indicate its cooling capacity is greater than 400 Watts, as expected, and it will be suitable for use in the RHIC ring. Presented are the modifications made to BNL's MAGCOOL test facility that were necessary for testing, test procedure, and recooler performance

  11. Brookhaven National Laboratory electron beam test stand

    International Nuclear Information System (INIS)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Prelec, K.; Snydstrup, L.

    1998-01-01

    The main purpose of the electron beam test stand (EBTS) project at the Brookhaven National Laboratory is to build a versatile device to develop technologies that are relevant for a high intensity electron beam ion source (EBIS) and to study the physics of ion confinement in a trap. The EBTS will have all the main attributes of EBIS: a 1-m-long, 5 T superconducting solenoid, electron gun, drift tube structure, electron collector, vacuum system, ion injection system, appropriate control, and instrumentation. Therefore it can be considered a short prototype of an EBIS for a relativistic heavy ion collider. The drift tube structure will be mounted in a vacuum tube inside a open-quotes warmclose quotes bore of a superconducting solenoid, it will be at room temperature, and its design will employ ultrahigh vacuum technology to reach the 10 -10 Torr level. The first gun to be tested will be a 10 A electron gun with high emission density and magnetic compression of the electron beam. copyright 1998 American Institute of Physics

  12. OPG Western Waste Management Facility

    Energy Technology Data Exchange (ETDEWEB)

    Julian, J. [Ontario Power Generation, Western Waste Management Facility, Tiverton, ON (Canada)

    2011-07-01

    The Ontario Power Generation (OPG) Western Waste Management Facility (WWMF) uses a computer based Supervisory Control and Data Acquisition (SCADA) system to monitor its facility, and control essential equipment. In 2007 the WWMF Low and Intermediate Level Waste (L&ILW) technical support section conducted a review of outstanding corrective maintenance work. Technical support divided all work on a system by system basis. One system under review was the Waste Volume Reduction Building (WVRB) control room SCADA system. Technical support worked with control maintenance staff to assess all outstanding work orders on the SCADA system. The assessment identified several deficiencies in the SCADA system. Technical support developed a corrective action plan for the SCADA system deficiencies, and in February of 2008 developed an engineering change package to correct the observed deficiencies. OPG Nuclear Waste Engineering approved the change package and the WVRB Control Room Upgrades construction project started in January of 2009. The WVRB control room upgrades construction work was completed in February of 2009. This paper provides the following information regarding the WWMF SCADA system and the 2009 WVRB Control Room Upgrades Project: A high-level explanation of SCADA system technology, and the various SCADA system components installed in the WVRB; A description of the state of the WVRB SCADA system during the work order assessment, identifying all deficiencies; A description of the new design package; A description of the construction project; and, A list of lessons learned during construction and commissioning, and a path forward for future upgrades. (author)

  13. OPG Western Waste Management Facility

    International Nuclear Information System (INIS)

    Julian, J.

    2011-01-01

    The Ontario Power Generation (OPG) Western Waste Management Facility (WWMF) uses a computer based Supervisory Control and Data Acquisition (SCADA) system to monitor its facility, and control essential equipment. In 2007 the WWMF Low and Intermediate Level Waste (L&ILW) technical support section conducted a review of outstanding corrective maintenance work. Technical support divided all work on a system by system basis. One system under review was the Waste Volume Reduction Building (WVRB) control room SCADA system. Technical support worked with control maintenance staff to assess all outstanding work orders on the SCADA system. The assessment identified several deficiencies in the SCADA system. Technical support developed a corrective action plan for the SCADA system deficiencies, and in February of 2008 developed an engineering change package to correct the observed deficiencies. OPG Nuclear Waste Engineering approved the change package and the WVRB Control Room Upgrades construction project started in January of 2009. The WVRB control room upgrades construction work was completed in February of 2009. This paper provides the following information regarding the WWMF SCADA system and the 2009 WVRB Control Room Upgrades Project: A high-level explanation of SCADA system technology, and the various SCADA system components installed in the WVRB; A description of the state of the WVRB SCADA system during the work order assessment, identifying all deficiencies; A description of the new design package; A description of the construction project; and, A list of lessons learned during construction and commissioning, and a path forward for future upgrades. (author)

  14. Design and Development of Layered Security: Future Enhancements and Directions in Transmission

    Science.gov (United States)

    Shahzad, Aamir; Lee, Malrey; Kim, Suntae; Kim, Kangmin; Choi, Jae-Young; Cho, Younghwa; Lee, Keun-Kwang

    2016-01-01

    Today, security is a prominent issue when any type of communication is being undertaken. Like traditional networks, supervisory control and data acquisition (SCADA) systems suffer from a number of vulnerabilities. Numerous end-to-end security mechanisms have been proposed for the resolution of SCADA-system security issues, but due to insecure real-time protocol use and the reliance upon open protocols during Internet-based communication, these SCADA systems can still be compromised by security challenges. This study reviews the security challenges and issues that are commonly raised during SCADA/protocol transmissions and proposes a secure distributed-network protocol version 3 (DNP3) design, and the implementation of the security solution using a cryptography mechanism. Due to the insecurities found within SCADA protocols, the new development consists of a DNP3 protocol that has been designed as a part of the SCADA system, and the cryptographically derived security is deployed within the application layer as a part of the DNP3 stack. PMID:26751443

  15. Design and Development of Layered Security: Future Enhancements and Directions in Transmission

    Directory of Open Access Journals (Sweden)

    Aamir Shahzad

    2016-01-01

    Full Text Available Today, security is a prominent issue when any type of communication is being undertaken. Like traditional networks, supervisory control and data acquisition (SCADA systems suffer from a number of vulnerabilities. Numerous end-to-end security mechanisms have been proposed for the resolution of SCADA-system security issues, but due to insecure real-time protocol use and the reliance upon open protocols during Internet-based communication, these SCADA systems can still be compromised by security challenges. This study reviews the security challenges and issues that are commonly raised during SCADA/protocol transmissions and proposes a secure distributed-network protocol version 3 (DNP3 design, and the implementation of the security solution using a cryptography mechanism. Due to the insecurities found within SCADA protocols, the new development consists of a DNP3 protocol that has been designed as a part of the SCADA system, and the cryptographically derived security is deployed within the application layer as a part of the DNP3 stack.

  16. National RF Test Facility as a multipurpose development tool

    International Nuclear Information System (INIS)

    McManamy, T.J.; Becraft, W.R.; Berry, L.A.

    1983-01-01

    Additions and modifications to the National RF Test Facility design have been made that (1) focus its use for technology development for future large systems in the ion cyclotron range of frequencies (ICRF), (2) expand its applicability to technology development in the electron cyclotron range of frequencies (ECRF) at 60 GHz, (3) provide a facility for ELMO Bumpy Torus (EBT) 60-GHz ring physics studies, and (4) permit engineering studies of steady-state plasma systems, including superconducting magnet performance, vacuum vessel heat flux removal, and microwave protection. The facility will continue to function as a test bed for generic technology developments for ICRF and the lower hybrid range of frequencies (LHRF). The upgraded facility is also suitable for mirror halo physics experiments

  17. Experience of 12 kA / 16 V SMPS during the HTS Current Leads Test

    Science.gov (United States)

    Panchal, P.; Christian, D.; Panchal, R.; Sonara, D.; Purwar, G.; Garg, A.; Nimavat, H.; Singh, G.; Patel, J.; Tanna, V.; Pradhan, S.

    2017-04-01

    As a part of up gradation plans in SST-1 Tokamak, one pair of 3.3 kA rated prototype hybrid current leads were developed using Di-BSCCO as High Temperature Superconductors (HTS) and the copper heat exchanger. In order to validate the manufacturing procedure prior to go for series production of such current leads, it was recommended to test these current leads using dedicated and very reliable DC switch mode power supply (SMPS). As part of test facility, 12 kA, 16 VDC programmable SMPS was successfully installed, commissioned and tested. This power supply has special features such as modularity, N+1 redundancy, very low ripple voltage, precise current measurements with Direct Current Current Transformer, CC/CV modes with auto-crossover and auto-sequence programming. As a part of acceptance of this converter, A 5.8 mΩ water-cooled resistive dummy load and PLC based SCADA system is designed, developed for commissioning of power supply. The same power supply was used for the testing of the prototype HTS current leads. The paper describes the salient features and experience of state-of-art of power supply and results obtained from this converter during the HTS current leads test.

  18. 78 FR 27984 - Modification of the National Customs Automation Program Test (NCAP) Regarding Reconciliation for...

    Science.gov (United States)

    2013-05-13

    ... Customs Automation Program Test (NCAP) Regarding Reconciliation for Filing Certain Post-Importation Claims... Automation Program (NCAP) Reconciliation prototype test to include the filing of post-importation [[Page... of the Test Reconciliation, a planned component of the National Customs Automation Program (NCAP), as...

  19. 49 CFR 195.446 - Control room management.

    Science.gov (United States)

    2010-10-01

    ... for the safe operation of a pipeline facility. (e) Alarm management. Each operator using a SCADA... controls all or part of a pipeline facility through a SCADA system. Each operator must have and follow... certain provisions of API RP 1165 are not practical for the SCADA system used; (2) Conduct a point-to...

  20. 78 FR 44142 - Modification of Two National Customs Automation Program (NCAP) Tests Concerning Automated...

    Science.gov (United States)

    2013-07-23

    ... Customs Automation Program (NCAP) Tests Concerning Automated Commercial Environment (ACE) Document Image... (CBP's) plan to modify the National Customs Automation Program (NCAP) tests concerning document imaging... entry process by reducing the number of data elements required to obtain release for cargo transported...

  1. Evaporation Basin Test Reactor Area, Idaho National Engineering Laboratory: Environmental assessment

    International Nuclear Information System (INIS)

    1991-12-01

    The Department of Energy (DOE) has prepared an environmental assessment (EA), DOE/EA-0501, on the construction and operation of the proposed Evaporation Basin at the Test Reactor Area (TRA) at the Idaho National Engineering Laboratory (INEL) near Idaho Falls, Idaho. Based on the analyses in the EA, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, the preparation of an environmental impact statement (EIS) is not required, and the Department is issuing this Finding of No Significant Impact

  2. The cross-national pattern of happiness. Test of predictions implied in three theories of happiness

    NARCIS (Netherlands)

    R. Veenhoven (Ruut); J.J. Ehrhardt (Joop)

    1995-01-01

    textabstractABSTRACT. Predictions about level and dispersion of happiness in nations are derived from three theories of happiness: comparison-theory, folklore-theory and livability-theory. The predictions are tested on two cross national data-sets: a comparative survey among university students in

  3. Preliminary Feasibility, Design, and Hazard Analysis of a Boiling Water Test Loop Within the Idaho National Laboratory Advanced Test Reactor National Scientific User Facility

    International Nuclear Information System (INIS)

    Gerstner, Douglas M.

    2009-01-01

    The Advanced Test Reactor (ATR) is a pressurized light-water reactor with a design thermal power of 250 MW. The principal function of the ATR is to provide a high neutron flux for testing reactor fuels and other materials. The ATR and its support facilities are located at the Idaho National Laboratory (INL). A Boiling Water Test Loop (BWTL) is being designed for one of the irradiation test positions within the. The objective of the new loop will be to simulate boiling water reactor (BWR) conditions to support clad corrosion and related reactor material testing. Further it will accommodate power ramping tests of candidate high burn-up fuels and fuel pins/rods for the commercial BWR utilities. The BWTL will be much like the pressurized water loops already in service in 5 of the 9 'flux traps' (region of enhanced neutron flux) in the ATR. The loop coolant will be isolated from the primary coolant system so that the loop's temperature, pressure, flow rate, and water chemistry can be independently controlled. This paper presents the proposed general design of the in-core and auxiliary BWTL systems; the preliminary results of the neutronics and thermal hydraulics analyses; and the preliminary hazard analysis for safe normal and transient BWTL and ATR operation

  4. 76 FR 34246 - Automated Commercial Environment (ACE); Announcement of National Customs Automation Program Test...

    Science.gov (United States)

    2011-06-13

    ... Environment (ACE); Announcement of National Customs Automation Program Test of Automated Procedures for In... Customs Automation Program (NCAP) test relating to highway movements of commercial goods that are transported in-bond through the United States from one point in Canada to another point in Canada. The NCAP...

  5. Scalable Asset Discovery, Vulnerability Scanning, and Penetration Testing for Remote Sites and Wireless Spectrums Utilizing an Embedded Linux Plug - PwniPlug and the Raspberry Pi B+ as a Sample Pen Test

    Science.gov (United States)

    Ganzy, Ethan G.

    2014-01-01

    All devices attached to the NASA KSC network are subject to security vulnerability scanning and/or penetration testing. In today's changing environment, vulnerable and/or unprotected systems can easily be overlooked. Systems that are not properly managed can become a potential threat to the operational integrity of our systems and networks. This includes all NASA (internal and external) information systems within NASA KSC Internet Protocol (IP) address space, and NASA KSC facilities. The Office of the Chief Information Officer (OCIO) recommends that all NASA Centers and information systems be subject to penetration testing on a regular interval in accordance with the guidelines identified by the National Institute of Standards and Technology (NIST). (ITS-HBK-2810.04-02A) Protecting information and equipment at NASA is an area of increasing concern. In addition to the CPU's on the network; Supervisory, Control and Data Acquisition (SCADA) systems are especially vulnerable because these systems have lacked standards, use embedded controllers with little computational power and informal software, are connected to physical processes, have few operators, and are increasingly also being connected to corporate networks. The scope of work is comprised of several individual components which together build upon previous work by Drew Branch, NASA KSC Intern. The Pwn Plug is the selected COTS (Commercial-Off-The-Shelf) device chosen to test simplification of mandatory IT Security tasks. The device will be utilized to provide services to NASA KSC and enable an assessment of infrastructure soundness and regulatory compliance in an efficient, economical, and business responsive manner. The Pwn Plug is designed as a pen testing appliance which provides a hardware platform that can support commercial penetration testing efforts at significantly reduced costs. The expected outcomes are: 1) External Penetration Testing, 2) Social Engineering, 3) Procedural Documentation, 4

  6. Quality Assurance in the National Tests of English: Investigating What Makes Reading Difficult

    Directory of Open Access Journals (Sweden)

    Angela Hasselgreen

    2017-09-01

    Full Text Available This article presents a piece of research, conducted in order to validate the claims made in test results, concerning what it means – in terms of reading ability – to be placed at a particular mastery level. It will consider the question of what makes reading tasks difficult, and whether data from the National Tests of English (NTE supports the progression of subskills/reading operations as presented in the mastery level descriptors, which are the basis of test results

  7. National Testing of Pupils in Europe: Objectives, Organisation and Use of Results. Austria 2009

    Science.gov (United States)

    Eurydice, 2009

    2009-01-01

    In contrast to many other European countries, national testing is a relatively new phenomenon in Austria's education system. Educational standards tests, aimed at providing a basis for monitoring and evaluating schools and the education system, were created in addition to the traditional system of continuous assessment. In Austria, pupils at ISCED…

  8. National Security Cutter: Enhanced Oversight Needed to Ensure Problems Discovered during Testing and Operations Are Addressed

    Science.gov (United States)

    2016-01-01

    May Lead to NSCs and Future DHS Assets Deploying without Having Demonstrated Full Capabilities 22 Performance Issues Discovered Outside of IOT &E...Examples of National Security Cutter Critical Operational Issues and Key Performance Parameters 10 Table 3: National Security Cutter Major...Cutter IOT &E Initial Operational Test and Evaluation KPP Key Performance Parameter LRI-II Long-Range Interceptor II NSC National Security Cutter

  9. Wind Resource Assessment – Østerild National Test Centre for Large Wind Turbines

    OpenAIRE

    Hansen, Brian Ohrbeck; Courtney, Michael; Mortensen, Niels Gylling

    2014-01-01

    This report presents a wind resource assessment for the seven test stands at the Østerild National Test Centre for Large Wind Turbines in Denmark. Calculations have been carried out mainly using wind data from three on-site wind lidars. The generalized wind climates applied in the wind resource calculations for the seven test stands are based on correlations between a short period of on-site wind data from the wind lidars with a long-term reference. The wind resource assessment for the seven ...

  10. Tests of qualification of national components of nuclear power plants under design basis accident

    International Nuclear Information System (INIS)

    Mesquita, A.Z.

    1990-01-01

    With the purpose of qualifying national components of nuclear power plants, whose working must be maintained during and after an accident, the Thermohydraulic Division of CDTN have done tests to check the equipment stability, under Design Basis Accident conditions. Until this moment, the following components were tested: electrical junction boxes (connectors); coating systems for wall, inside cover and steel containment; hydraulics components of personnel and equipment airlock. This work describes the test instalation, the tests performed and its results. The components tested, in a general way, fulfil the specified requirements. (author) [pt

  11. NNWSI waste form testing at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.; Abrajano, T.A. Jr.; Ebert, W.L.; Mazer, J.J.

    1988-11-01

    The Nevada Nuclear Waste Storage Investigation (NNWSI) Project is investigating the tuff beds of Yucca Mountain, Nevada, as a potential location for a high-level radioactive waste repository. As part of the waste package development portion of this project, experiments are being performed by the Chemical Technology Division of Argonne National Laboratory to study the behavior of the waste form under anticipated repository conditions. These experiments include the development and performance of a test to measure waste form behavior in unsaturated conditions and the performance of experiments designed to study the behavior of waste package components in an irradiated environment. Previous reports document developments in these areas through 1986. This report summarizes progress during the period January--June 1987, 19 refs., 17 figs., 20 tabs

  12. 2016 Annual Site Environmental report Sandia National Laboratories Tonopah Test Range Nevada & Kaua'i Test Facility Hawai'i.

    Energy Technology Data Exchange (ETDEWEB)

    Salas, Angela Maria [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Griffith, Stacy R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Sandia National Laboratories (SNL) is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s (DOE’s), National Nuclear Security Administration (NNSA) under contract DE-NA0003525. The DOE/NNSA Sandia Field Office administers the contract and oversees contractor operations at the SNL, Tonopah Test Range (SNL/TTR) in Nevada and the SNL, Kaua‘i Test Facility (SNL/KTF) in Hawai‘i. SNL personnel manage and conduct operations at SNL/TTR in support of the DOE/NNSA’s Weapons Ordnance Program and have operated the site since 1957. Navarro Research and Engineering personnel perform most of the environmental programs activities at SNL/TTR. The DOE/NNSA/Nevada Field Office retains responsibility for cleanup and management of SNL/TTR Environmental Restoration sites. SNL personnel operate SNL/KTF as a rocket preparation launching and tracking facility. This Annual Site Environmental Report (ASER) summarizes data and the compliance status of sustainability, environmental protection, and monitoring programs at SNL/TTR and SNL/KTF during calendar year 2016. Major environmental programs include air quality, water quality, groundwater protection, terrestrial and biological surveillance, waste management, pollution prevention, environmental restoration, oil and chemical spill prevention, and implementation of the National Environmental Policy Act. This ASER is prepared in accordance with and as required by DOE O 231.1B, Admin Change 1, Environment, Safety, and Health Reporting.

  13. Fidelity of test development process within a national science grant

    Science.gov (United States)

    Brumfield, Teresa E.

    In 2002, a math-science partnership (MSP) program was initiated by a national science grant. The purpose of the MSP program was to promote the development, implementation, and sustainability of promising partnerships among institutions of higher education, K-12 schools and school systems, as well as other important stakeholders. One of the funded projects included a teacher-scientist collaborative that instituted a professional development system to prepare teachers to use inquiry-based instructional modules. The MSP program mandated evaluations of its funded projects. One of the teacher-scientist collaborative project's outcomes specifically focused on teacher and student science content and process skills. In order to provide annual evidence of progress and to measure the impact of the project's efforts, and because no appropriate science tests were available to measure improvements in content knowledge of participating teachers and their students, the project contracted for the development of science tests. This dissertation focused on the process of test development within an evaluation and examined planned (i.e., expected) and actual (i.e., observed) test development, specifically concentrating on the factors that affected the actual test development process. Planned test development was defined as the process of creating tests according to the well-established test development procedures recommended by the AERA/APA/NCME 1999 Standards for Educational and Psychological Testing. Actual test development was defined as the process of creating tests as it actually took place. Because case study provides an in-depth, longitudinal examination of an event (i.e., case) in a naturalistic setting, it was selected as the appropriate methodology to examine the difference between planned and actual test development. The case (or unit of analysis) was the test development task, a task that was bounded by the context in which it occurred---and over which this researcher had

  14. National Aeronautics Research, Development, Test and Evaluation (RDT&E) Infrastructure Plan

    Science.gov (United States)

    2011-01-01

    addressed in the National Aeronautics R&D Plan, identi- fying unnecessary redundancy solely on the basis of infrastructure required to support H H13 ...near, mid, and far terms, and impact not only scramjet propulsion systems, but potential turbine-based combined cycle systems as well. Turbine Engine...Icing Test Facilities A greater understanding of the impact that icing conditions have on turbine engine opera- tions is needed to develop enhanced

  15. Norwegian Cyber Defense

    Science.gov (United States)

    2013-12-01

    reliance on proprietary networks and hardware, SCADA systems were considered safe from cyber attacks and were not designed for security. The situation...operational data that could result in public safety concerns.43 In 2013 Norwegian newspaper Dagbladet found over 2,500 SCADA systems in Norway used for ...a. Siberian Pipeline Explosion (1982) In 1982, intruders planted a Trojan horse in the SCADA system that controls the Siberian Pipeline . This is the

  16. Advancing nuclear technology and research. The advanced test reactor national scientific user facility

    Energy Technology Data Exchange (ETDEWEB)

    Benson, Jeff B; Marshall, Frances M [Idaho National Laboratory, Idaho Falls, ID (United States); Allen, Todd R [Univ. of Wisconsin, Madison, WI (United States)

    2012-03-15

    The Advanced Test Reactor (ATR), at the Idaho National Laboratory (INL), is one of the world's premier test reactors for providing the capability for studying the effects of intense neutron and gamma radiation on reactor materials and fuels. The INL also has several hot cells and other laboratories in which irradiated material can be examined to study material radiation effects. In 2007 the US Department of Energy (DOE) designated the ATR as a National Scientific User Facility (NSUF) to facilitate greater access to the ATR and the associated INL laboratories for material testing research. The mission of the ATR NSUF is to provide access to world-class facilities, thereby facilitating the advancement of nuclear science and technology. Cost free access to the ATR, INL post irradiation examination facilities, and partner facilities is granted based on technical merit to U.S. university-led experiment teams conducting non-proprietary research. Proposals are selected via independent technical peer review and relevance to United States Department of Energy. To increase overall research capability, ATR NSUF seeks to form strategic partnerships with university facilities that add significant nuclear research capability to the ATR NSUF and are accessible to all ATR NSUF users. (author)

  17. Neural networks used to monitor an experimental test workbench

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Davi Almeida; Pereira, Iraci Martinez, E-mail: dmoraes@dk8.com.br, E-mail: martinez@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    This work presents the application of neural networks in an experimental workbench. This bench was developed with the purpose of conducting real time tests and data acquisition. The method applied for this work allowed to generate faulty data in a gradual and controlled way through the binary combination of double action valves. Using the SCADA application (Supervisory Control and Data Acquisition), it became possible to acquire data for analysis in Matlab / Simulink software. This bench has two reservoirs: a reservoir that has sensors for recording pressure and temperature variables for later analysis, and another reservoir that has level sensors. Four models were used to develop the respective practical experiments. In the first model, it was possible to perform all practical tests of the plant, as well as mechanical changes like repositioning of some mechanical components, piping, sensors and electrovalves. In the second model, it was noticed that the positioning of the flow meter, located after the pump output, prevented a good measurement of the flow variable. In the third model, it was perceived that the number of failures initially adopted, made the data too confusing for the neural network analysis. In the last model, it was possible to obtain a performance of 96.6% of hits after the reconfiguration for 4 controlled faults. (author)

  18. Neural networks used to monitor an experimental test workbench

    International Nuclear Information System (INIS)

    Moraes, Davi Almeida; Pereira, Iraci Martinez

    2017-01-01

    This work presents the application of neural networks in an experimental workbench. This bench was developed with the purpose of conducting real time tests and data acquisition. The method applied for this work allowed to generate faulty data in a gradual and controlled way through the binary combination of double action valves. Using the SCADA application (Supervisory Control and Data Acquisition), it became possible to acquire data for analysis in Matlab / Simulink software. This bench has two reservoirs: a reservoir that has sensors for recording pressure and temperature variables for later analysis, and another reservoir that has level sensors. Four models were used to develop the respective practical experiments. In the first model, it was possible to perform all practical tests of the plant, as well as mechanical changes like repositioning of some mechanical components, piping, sensors and electrovalves. In the second model, it was noticed that the positioning of the flow meter, located after the pump output, prevented a good measurement of the flow variable. In the third model, it was perceived that the number of failures initially adopted, made the data too confusing for the neural network analysis. In the last model, it was possible to obtain a performance of 96.6% of hits after the reconfiguration for 4 controlled faults. (author)

  19. Verification testing of the PKI collector at Sandia National Laboratories, Albuquerque, New Mexico

    Science.gov (United States)

    Hauger, J. S.; Pond, S. L.

    1982-07-01

    Verification testing of a solar collector was undertaken prior to its operation as part of an industrial process heat plant at Capitol Concrete Products in Topeka, Kansas. Testing was performed at a control plant installed at Sandia National Laboratory, Albuquerque, New Mexico (SNLA). Early results show that plant performance is even better than anticipated and far in excess of test criteria. Overall plant efficiencies of 65 to 80 percent were typical during hours of good insolation. A number of flaws and imperfections were detected during operability testing, the most important being a problem in elevation drive alignment due to a manufacturing error. All problems were corrected as they occurred and the plant, with over 40 hours of operation, is currently continuing operability testing in a wholly-automatic mode.

  20. Current use of pharmacogenetic testing: a national survey of thiopurine methyltransferase testing prior to azathioprine prescription.

    Science.gov (United States)

    Fargher, E A; Tricker, K; Newman, W; Elliott, R; Roberts, S A; Shaffer, J L; Bruce, I; Payne, K

    2007-04-01

    AZA treatment. Uptake differs between specialities. High uptake of TPMT enzyme-level testing by dermatologists, compared with gastroenterologists and rheumatologists, may reflect national guidelines advocating its use prior to AZA. Uptake of enzyme-level testing may alter in other specialties as other guidelines are developed.

  1. Papers of the PTAC wireless, telecommunications and e-business forum : using wireless, SCADA, and well data life cycle management technology to boost productivity and reduce costs in the upstream oil and gas industry

    International Nuclear Information System (INIS)

    2004-01-01

    The main focus of this forum was the use of wireless, telecommunications and e-business as a means of improving efficiency and productivity in the upstream oil and gas industry. The use of new communications technologies in asset monitoring and business performance was discussed, as well as industrial automation and wireless connectivity in conjunction with Supervisory Control and Data Acquisition (SCADA) systems. New technologies in the areas of maintenance and decision support and synergy integration were introduced. New health, safety and environmental performance tools were presented. Issues concerning secure communications and document exchange expenses were also introduced, as well as different methods of closing data gaps between joint interest partners. Specific tools and software concerning compliance management with web-based and remote field data capture technology were discussed, as well as the collection and display of well-site data using newly developed BlueGauge technology. Eleven papers were presented in this forum, of which three were catalogued separately for inclusion in this database. tabs., figs

  2. Papers of the PTAC wireless, telecommunications and e-business forum : using wireless, SCADA, and well data life cycle management technology to boost productivity and reduce costs in the upstream oil and gas industry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    The main focus of this forum was the use of wireless, telecommunications and e-business as a means of improving efficiency and productivity in the upstream oil and gas industry. The use of new communications technologies in asset monitoring and business performance was discussed, as well as industrial automation and wireless connectivity in conjunction with Supervisory Control and Data Acquisition (SCADA) systems. New technologies in the areas of maintenance and decision support and synergy integration were introduced. New health, safety and environmental performance tools were presented. Issues concerning secure communications and document exchange expenses were also introduced, as well as different methods of closing data gaps between joint interest partners. Specific tools and software concerning compliance management with web-based and remote field data capture technology were discussed, as well as the collection and display of well-site data using newly developed BlueGauge technology. Eleven papers were presented in this forum, of which three were catalogued separately for inclusion in this database. tabs., figs.

  3. Refurbishment and Automation of the Thermal/Vacuum Facilities at the Goddard Space Flight Center

    Science.gov (United States)

    Donohue, John T.; Johnson, Chris; Ogden, Rick; Sushon, Janet

    1998-01-01

    The thermal/vacuum facilities located at the Goddard Space Flight Center (GSFC) have supported both manned and unmanned space flight since the 1960s. Of the 11 facilities, currently 10 of the systems are scheduled for refurbishment and/or replacement as part of a 5-year implementation. Expected return on investment includes the reduction in test schedules, improvements in the safety of facility operations, reduction in the complexity of a test and the reduction in personnel support required for a test. Additionally, GSFC will become a global resource renowned for expertise in thermal engineering, mechanical engineering and for the automation of thermal/vacuum facilities and thermal/vacuum tests. Automation of the thermal/vacuum facilities includes the utilization of Programmable Logic Controllers (PLCs) and the use of Supervisory Control and Data Acquisition (SCADA) systems. These components allow the computer control and automation of mechanical components such as valves and pumps. In some cases, the chamber and chamber shroud require complete replacement while others require only mechanical component retrofit or replacement. The project of refurbishment and automation began in 1996 and has resulted in the computer control of one Facility (Facility #225) and the integration of electronically controlled devices and PLCs within several other facilities. Facility 225 has been successfully controlled by PLC and SCADA for over one year. Insignificant anomalies have occurred and were resolved with minimal impact to testing and operations. The amount of work remaining to be performed will occur over the next four to five years. Fiscal year 1998 includes the complete refurbishment of one facility, computer control of the thermal systems in two facilities, implementation of SCADA and PLC systems to support multiple facilities and the implementation of a Database server to allow efficient test management and data analysis.

  4. 2013 Annual Site Environmental Report for Sandia National Laboratories Tonopah Test Range Nevada & Kauai Test Facility Hawaii

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, Stacy Rene [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Agogino, Karen [National Nuclear Security Administration (NNSA), Washington, DC (United States); Li, Jun [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); White, Nancy [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Minitrez, Alexandra [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Avery, Penny [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Bailey-White, Brenda [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Bonaguidi, Joseph [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Catechis, Christopher [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); duMond, Michael [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Eckstein, Joanna [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Evelo, Stacie [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Forston, William [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Herring, III, Allen [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Lantow, Tiffany [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Martinez, Reuben [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Mauser, Joseph [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Miller, Amy [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Miller, Mark [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Payne, Jennifer [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Peek, Dennis [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Reiser, Anita [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Ricketson, Sherry [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Roma, Charles [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Salinas, Stephanie [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Ullrich, Rebecca [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2014-08-01

    Tonopah Test Range (TTR) in Nevada and Kauai Test Facility (KTF) in Hawaii are government-owned, contractor-operated facilities managed and operated by Sandia Corporation (Sandia), a wholly owned subsidiary of Lockheed Martin Corporation. The U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA), through the Sandia Field Office (SFO), in Albuquerque, New Mexico, administers the contract and oversees contractor operations at TTR and KTF. Sandia manages and conducts operations at TTR in support of the DOE/NNSA’s Weapons Ordnance Program and has operated the site since 1957. Navarro Research and Engineering subcontracts to Sandia in administering most of the environmental programs at TTR. Sandia operates KTF as a rocket preparation launching and tracking facility. This Annual Site Environmental Report summarizes data and the compliance status of the sustainability, environmental protection, and monitoring program at TTR and KTF through Calendar Year 2013. The compliance status of environmental regulations applicable at these sites include state and federal regulations governing air emissions, wastewater effluent, waste management, terrestrial surveillance, Environmental Restoration (ER) cleanup activities, and the National Environmental Policy Act. Sandia is responsible only for those environmental program activities related to its operations. The DOE/NNSA/Nevada Field Office retains responsibility for the cleanup and management of TTR ER sites. Environmental monitoring and surveillance programs are required by DOE Order 231.1B, Environment, Safety, and Health Reporting (DOE 2012).

  5. Idaho National Engineering Laboratory, Test Area North, Hangar 629 -- Photographs, written historical and descriptive data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The report describes the history of the Idaho National Engineering Laboratory`s Hangar 629. The hangar was built to test the possibility of linking jet engine technology with nuclear power. The history of the project is described along with the development and eventual abandonment of the Flight Engine Test hangar. The report contains historical photographs and architectural drawings.

  6. Reactor training simulator for the Replacement Research Reactor (RRR)

    International Nuclear Information System (INIS)

    Etchepareborda, A; Flury, C.A; Lema, F; Maciel, F; Alegrechi, D; Damico, M; Ibarra, G; Muguiro, M; Gimenez, M; Schlamp, M; Vertullo, A

    2004-01-01

    The main features of the ANSTO Replacement Research Reactor (RRR) Reactor Training Simulator (RTS) are presented.The RTS is a full-scope and partial replica simulator.Its scope includes a complete set of plant normal evolutions and malfunctions obtained from the plant design basis accidents list.All the systems necessary to implement the operating procedures associated to these transients are included.Within these systems both the variables connected to the plant SCADA and the local variables are modelled, leading to several thousands input-output variables in the plant mathematical model (PMM).The trainee interacts with the same plant SCADA, a Foxboro I/A Series system.Control room hardware is emulated through graphical displays with touch-screen.The main system models were tested against RELAP outputs.The RTS includes several modules: a model manager (MM) that encapsulates the plant mathematical model; a simulator human machine interface, where the trainee interacts with the plant SCADA; and an instructor console (IC), where the instructor commands the simulation.The PMM is built using Matlab-Simulink with specific libraries of components designed to facilitate the development of the nuclear, hydraulic, ventilation and electrical plant systems models [es

  7. Lawrence Livermore National Laboratory underground coal gasification data base. [US DOE-supported field tests; data

    Energy Technology Data Exchange (ETDEWEB)

    Cena, R. J.; Thorsness, C. B.

    1981-08-21

    The Department of Energy has sponsored a number of field projects to determine the feasibility of converting the nation's vast coal reserves into a clean efficient energy source via underground coal gasification (UCG). Due to these tests, a significant data base of process information has developed covering a range of coal seams (flat subbituminous, deep flat bituminous and steeply dipping subbituminous) and processing techniques. A summary of all DOE-sponsored tests to data is shown. The development of UCG on a commercial scale requires involvement from both the public and private sectors. However, without detailed process information, accurate assessments of the commercial viability of UCG cannot be determined. To help overcome this problem the DOE has directed the Lawrence Livermore National Laboratory (LLNL) to develop a UCG data base containing raw and reduced process data from all DOE-sponsored field tests. It is our intent to make the data base available upon request to interested parties, to help them assess the true potential of UCG.

  8. Breath tests sustainability in hospital settings: cost analysis and reimbursement in the Italian National Health System.

    Science.gov (United States)

    Volpe, M; Scaldaferri, F; Ojetti, V; Poscia, A

    2013-01-01

    The high demand of Breath Tests (BT) in many gastroenterological conditions in time of limited resources for health care systems, generates increased interest in cost analysis from the point of view of the delivery of services to better understand how use the money to generate value. This study aims to measure the cost of C13 Urea and other most utilized breath tests in order to describe key aspects of costs and reimbursements looking at the economic sustainability for the hospital. A hospital based cost-analysis of the main breath tests commonly delivery in an ambulatory setting is performed. Mean salary for professional nurses and gastroenterologists, drugs/preparation used and disposable materials, purchase and depreciation of the instrument and the testing time was used to estimate the cost, while reimbursements are based on the 2013 Italian National Health System ambulatory pricelist. Variables that could influence the model are considered in the sensitivity analyses. The mean cost for C13--Urea, Lactulose and Lactose BT are, respectively, Euros 30,59; 45,20 and 30,29. National reimbursement often doesn't cover the cost of the analysis, especially considering the scenario with lower number of exam. On the contrary, in high performance scenario all the reimbursement could cover the cost, except for the C13 Urea BT that is high influenced by the drugs cost. However, consideration about the difference between Italian Regional Health System ambulatory pricelist are done. Our analysis shows that while national reimbursement rates cover the costs of H2 breath testing, they do not cover sufficiently C13 BT, particularly urea breath test. The real economic strength of these non invasive tests should be considered in the overall organization of inpatient and outpatient clinic, accounting for complete diagnostic pathway for each gastrointestinal disease.

  9. 78 FR 60898 - Regulation on Definition and Requirements for a Nationally Recognized Testing Laboratory...

    Science.gov (United States)

    2013-10-02

    ...] Regulation on Definition and Requirements for a Nationally Recognized Testing Laboratory; Revision of the Office of Management and Budget's (OMB) Approval of Information Collection (Paperwork) Requirements... collection requirements specified by its Regulation at 29 CFR 1910.7, ``definition and requirements for a...

  10. Cyber security of critical infrastructures

    Directory of Open Access Journals (Sweden)

    Leandros A. Maglaras

    2018-03-01

    Full Text Available Modern Supervisory Control and Data Acquisition (SCADA systems are essential for monitoring and managing electric power generation, transmission and distribution. In the age of the Internet of Things, SCADA has evolved into big, complex and distributed systems that are prone to be conventional in addition to new threats. Many security methods can be applied to such systems, having in mind that both high efficiency, real time intrusion identification and low overhead are required. Keywords: SCADA systems, Security

  11. Inter operability of smart field devices on an open field-bus: from laboratory tests to on-site applications

    International Nuclear Information System (INIS)

    Piguet, M.; Favennec, J.M.

    1997-01-01

    The paper presents a field trial held in EDF's R and D laboratories concerning smart field instruments (sensors, I/O modules, transmitters) operating on the WorldFIP field-bus. The trial put into operation a supervisory control and data acquisition (SCADA) system on the field-bus with available industrial field devices and software tools. The field trial enables EDF's teams to address the inter-operability issue regarding smart field devices and to prepare the forthcoming step from analog to fully digital measurement technology by evaluating new services and higher performances provided. Possible architectures for process control and on-site testing purposes have been identified. A first application for a flow-measuring rig is under way. It implements a WorldFIP field-bus based DCS with FIP/HART multiplexers, FIP and HART smart devices (sensors and actuators) and a field management system. (authors)

  12. Optimisation of Data Acquisition in Wind Turbines with Data-Driven Conversion Functions for Sensor Measurements

    DEFF Research Database (Denmark)

    Colone, Lorenzo; Reder, M.; Tautz-Weinert, J.

    2017-01-01

    and evaluate their performance. A subsequent sensitivity analysis measuring the impact of the input variables on the predicted response reveals hidden relationships between signals. The concept feasibility is tested in a case study using Supervisory Control And Data Acquisition (SCADA) data from an offshore...

  13. 78 FR 5430 - Extension of Approval Period for Certain Tests Used in the National Reporting System for Adult...

    Science.gov (United States)

    2013-01-25

    ... DEPARTMENT OF EDUCATION Extension of Approval Period for Certain Tests Used in the National Reporting System for Adult Education AGENCY: Office of Vocational and Adult Education, Department of... National Reporting System for Adult Education (NRS regulations) (73 FR 2306). The NRS regulations...

  14. Vehicle Testing and Integration Facility; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-03-02

    Engineers at the National Renewable Energy Laboratory’s (NREL’s) Vehicle Testing and Integration Facility (VTIF) are developing strategies to address two separate but equally crucial areas of research: meeting the demands of electric vehicle (EV) grid integration and minimizing fuel consumption related to vehicle climate control. Dedicated to renewable and energy-efficient solutions, the VTIF showcases technologies and systems designed to increase the viability of sustainably powered vehicles. NREL researchers instrument every class of on-road vehicle, conduct hardware and software validation for EV components and accessories, and develop analysis tools and technology for the Department of Energy, other government agencies, and industry partners.

  15. The Reliability of Results from National Tests, Public Examinations, and Vocational Qualifications in England

    Science.gov (United States)

    He, Qingping; Opposs, Dennis

    2012-01-01

    National tests, public examinations, and vocational qualifications in England are used for a variety of purposes, including the certification of individual learners in different subject areas and the accountability of individual professionals and institutions. However, there has been ongoing debate about the reliability and validity of their…

  16. Using Physical Models for Anomaly Detection in Control Systems

    Science.gov (United States)

    Svendsen, Nils; Wolthusen, Stephen

    Supervisory control and data acquisition (SCADA) systems are increasingly used to operate critical infrastructure assets. However, the inclusion of advanced information technology and communications components and elaborate control strategies in SCADA systems increase the threat surface for external and subversion-type attacks. The problems are exacerbated by site-specific properties of SCADA environments that make subversion detection impractical; and by sensor noise and feedback characteristics that degrade conventional anomaly detection systems. Moreover, potential attack mechanisms are ill-defined and may include both physical and logical aspects.

  17. Destructive Testing of an ES-3100 Shipping Container at the Savannah River National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Loftin, B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Abramczyk, G. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-06-09

    Destructive testing of an ES-3100 Shipping Container was completed by the Packaging Technology and Pressurized Systems organization within the Savannah River National Laboratory in order to qualify the ES-3100 as a candidate storage and transport package for applications at various facilities at the Savannah River Site. The testing consisted of the detonation of three explosive charges at separate locations on a single ES-3100. The locations for the placement were chosen based the design of the ES-3100 as well as the most likely places for the package to incur damage as a result of the detonation. The testing was completed at an offsite location, which raised challenges as well as allowed for development of new partnerships for this testing and for potential future testing. The results of the testing, the methods used to complete the testing, and similar, potential future work will be discussed.

  18. In situ vitrification application to buried waste: Final report of intermediate field tests at Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Callow, R.A.; Weidner, J.R.; Loehr, C.A.; Bates, S.O.; Thompson, L.E.; McGrail, B.P.

    1991-08-01

    This report describes two in situ vitrification field tests conducted on simulated buried waste pits during June and July 1990 at the Idaho National Engineering Laboratory. In situ vitrification, an emerging technology for in place conversion of contaminated soils into a durable glass and crystalline waste form, is being investigated as a potential remediation technology for buried waste. The overall objective of the two tests was to access the general suitability of the process to remediate waste structures representative of buried waste found at Idaho National Engineering Laboratory. In particular, these tests, as part of a treatability study, were designed to provide essential information on the field performance of the process under conditions of significant combustible and metal wastes and to test a newly developed electrode feed technology. The tests were successfully completed, and the electrode feed technology successfully processed the high metal content waste. Test results indicate the process is a feasible technology for application to buried waste. 33 refs., 109 figs., 39 tabs

  19. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, Andrew A.; Ghanouni, Alex; Rees, Colin J.; Hewitson, Paul; Nickerson, Claire; Wright, Suzanne; Taylor, Stuart A.; Halligan, Steve; von Wagner, Christian

    2016-01-01

    Objective To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. Methods Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as compl...

  20. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, A. A.; Ghanouni, A.; Rees, C. J.; Hewitson, P.; Nickerson, C.; Wright, S.; Taylor, S. A.; Halligan, S.; von Wagner, C.

    2017-01-01

    OBJECTIVE: To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. METHODS: Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as com...

  1. Relationship between concussion history and neurocognitive test performance in National Football League draft picks.

    Science.gov (United States)

    Solomon, Gary S; Kuhn, Andrew

    2014-04-01

    There are limited empirical data available regarding the relationship between concussion history and neurocognitive functioning in active National Football League (NFL) players in general and NFL draft picks in particular. Potential NFL draft picks undergo 2 neurocognitive tests at the National Invitational Camp (Scouting Combine) every year: the Wonderlic and, since 2011, the Immediate Post-concussion Assessment and Cognitive Testing (ImPACT). After conclusion of the combine and before the draft, NFL teams invite potential draft picks to their headquarters for individual visits where further assessment may occur. To examine the relationship between concussion history and neurocognitive performance (ImPACT and Wonderlic) in a sample of elite NFL draft picks. Cohort study; Level of evidence, 3. Over 7 years, 226 potential draft picks were invited to visit a specific NFL team's headquarters after the combine. The athletes were divided into 3 groups based on self-reported concussion history: no prior concussions, 1 prior concussion, and 2 or more prior concussions. Neurocognitive measures of interest included Wonderlic scores (provided by the NFL team) and ImPACT composite scores (administered either at the combine or during a visit to the team headquarters). The relationship between concussion history and neurocognitive scores was assessed, as were the relationships among the 2 neurocognitive tests. Concussion history had no relationship to neurocognitive performance on either the Wonderlic or ImPACT. Concussion history did not affect performance on either neurocognitive test, suggesting that for this cohort, a history of concussion may not have adverse effects on neurocognitive functioning as measured by these 2 tests. This study reveals no correlation between concussion history and neurocognitive test scores (ImPACT, Wonderlic) in soon-to-be active NFL athletes.

  2. Design and Implementation of a Secure Modbus Protocol

    Science.gov (United States)

    Fovino, Igor Nai; Carcano, Andrea; Masera, Marcelo; Trombetta, Alberto

    The interconnectivity of modern and legacy supervisory control and data acquisition (SCADA) systems with corporate networks and the Internet has significantly increased the threats to critical infrastructure assets. Meanwhile, traditional IT security solutions such as firewalls, intrusion detection systems and antivirus software are relatively ineffective against attacks that specifically target vulnerabilities in SCADA protocols. This paper describes a secure version of the Modbus SCADA protocol that incorporates integrity, authentication, non-repudiation and anti-replay mechanisms. Experimental results using a power plant testbed indicate that the augmented protocol provides good security functionality without significant overhead.

  3. Simulation of wake effects between two wind farms

    DEFF Research Database (Denmark)

    Hansen, Kurt Schaldemose; Réthoré, Pierre-Elouan; Palma, Jose

    2015-01-01

    SCADA data, recorded on the downstream wind farm, has been used to identify flow cases with visible clustering effects. The inflow condition is derived from a partly undisturbed wind turbine, due to lack of mast measurements. The SCADA data analysis concludes that centre of the deficit...... flow models represented in this benchmark include both RANS models, mesoscale models and engineering models. The flow cases, identified according to the wind speed level and inflow sector, have been simulated and validated with the SCADA results. The model validation concludes that all models more...

  4. AN APPLICATION EXAMPLE ; FAULT DIAGNOSIS IN POWER SYSTEM

    Directory of Open Access Journals (Sweden)

    Özgür COŞAR

    2003-02-01

    Full Text Available There are a lot of protective devices in electrical transmission and distribution systems which are monitored and data are collected from these devices via Supervisory Control and Data Acquisition System (SCADA. distribution systems are more complicated when compared with transmission systems. However, SCADA is not available in most distribution systems where phones from the customers are used as alarms. In the cases where SCADA is not available experiences of the dispatchers and the information from customers becomes important. In this work a user friendly software is developed for even unexperienced dispatchers.

  5. Friction testing for the National Highway System for 2001 : all Louisiana districts : technical assistance report.

    Science.gov (United States)

    2002-11-01

    This report contains the results of friction testing conducted by the pavement/systems group of the Louisiana Transportation Research Center (LTRC) on the National Highway System (NHS) in 2000 and 2001. The data contained in this report covers all Lo...

  6. Report of test and research results on atomic energy obtained in national institutes in fiscal 1990

    International Nuclear Information System (INIS)

    1991-01-01

    The tests and researches on the development and utilization of atomic energy in national laboratories were begun in 1956, and have accomplished the great role for the advance of the development and utilization of atomic energy in Japan by having produced many valuable results so far. Atomic energy has been utilized in diverse fields, and also in national laboratories, the research for expanding the development and utilization of atomic energy in food irradiation, medicine, agriculture, forestry, fishery and others in addition to the basic research on nuclear fusion and safety have been advanced. Further expecting the pervasive effect to general science and technology, the development of basic technology and integrated research are promoted from the viewpoint of new techical innovation and creative technology. This is 31st report in which the results of the tests and researches carried out by national laboratories in fiscal year 1990 are summarized. Nuclear fusion, safety research, food irradiation, cancer countermeasures, agriculture, forestry, fishery, medicine, mining and manufacture, power utilization, construction, radioactivation analysis and so on were the main subjects. (K.I.)

  7. Detection of Periodic Beacon Loads in Electrical Distribution Substation Data

    Energy Technology Data Exchange (ETDEWEB)

    Hammerstrom, Donald J.; Guttromson, Ross T.; Lu, Ning; Boyd, Paul A.; Trudnowski, Daniel; Chassin, David P.; Bonebrake, Christopher A.; Shaw, James M.

    2006-05-31

    This research explores methods for identifying a whether a load is sending a signal to the utility SCADA system. Such a system can identify whether various loads are signialing using existing SCADA infrastructure, that is, without added, high cost communications infrastructure.

  8. In situ vitrification application to buried waste: Interim report of intermediate field tests at Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Callow, R.A.; Weidner, J.R.; Thompson, L.E.

    1991-02-01

    This report describes the two in situ vitrification field tests conducted in June and July 1990 at Idaho National Engineering Laboratory. In situ vitrification, an emerging technology for in- place conversion of contaminated soils into a durable glass and crystalline waste form, is being investigated as a potential remediation technology for buried waste. The overall objective of the two tests was to assess the general suitability of the process to remediate waste structures representative of buried waste found at Idaho National engineering Laboratory. In particular, these tests, as part of a treatability study, were designed to provide essential information on the field performance of the process under conditions of significant combustible and metal wastes and to test a newly developed electrode feed technology. The tests were successfully completed, and the electrode feed technology successfully processed the high metal content waste, indicating the process is a feasible technology for application to buried waste

  9. In situ vitrification application to buried waste: Interim report of intermediate field tests at Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Callow, R.A.; Weidner, J.R.; Thompson, L.E.

    1991-01-01

    This report describes the two in situ vitrification field tests conducted in July and July 1990 at Idaho National Engineering Laboratory. In situ vitrification, an emerging technology for in-place conversion of contaminated soils into a durable glass and crystalline waste form, is being investigated as a potential remediation technology for buried waste. The overall objective of the two tests was to assess the general suitability of the process to remediate waste structures representative of buried waste found at Idaho National Engineering Laboratory. In particular, these tests, as part of a treatability study, were designed to provide essential information field performance of the process under conditions of significant combustible and metal wastes and to test a newly developed electrode feed technology. The tests were successfully completed, and the electrode feed technology successfully processed the high metal content waste, indicating the process is a feasible technology for application to buried waste. 8 refs., 91 figs., 13 tabs

  10. Overuse of preoperative laboratory coagulation testing and ABO blood typing: a French national study.

    Science.gov (United States)

    Beloeil, H; Ruchard, D; Drewniak, N; Molliex, S

    2017-12-01

    Following publication of guidelines on routine preoperative tests, the French Society of Anaesthesiology and Intensive Care (SFAR), in association with French national public health insurance, conducted a survey to evaluate adherence to guidelines and the economic consequences. Using the French Hospital Discharge Database and National Health Insurance Information system, tests performed during the 30 days before surgery were analysed for two situations: (1) standard laboratory coagulation tests and ABO blood typing in children able to walk and scheduled for tonsillectomy/adenoidectomy; and (2) ABO blood typing in adults before laparoscopic cholecystectomy, thyroidectomy, lumbar discectomy or breast surgery. Guidelines do not recommend any preoperative tests in these settings. Between 2013 and 2015, a coagulation test was performed in 49% of the 241 017 children who underwent tonsillectomy and 39% of the 133 790 children who underwent adenoidectomy. A similar pattern was observed for ABO blood typing although re-operation rates for bleeding on the first postoperative day were very low (0.12-0.31% for tonsillectomy and 0.01-0.02% for adenoidectomy). Between 2012 and 2015, ABO blood typing was performed in 32-45% of the 1 114 082 patients who underwent one of the four selected procedures. The transfusion rate was very low (0.02-0.31%). The mean cost for the four procedures over the 4 yr period was €5 310 000 (sd €325 000). Standard laboratory coagulation tests and ABO blood typing are still routinely prescribed before surgery and anaesthesia despite current guidelines. This over-prescription represents a high and unnecessary cost, and should therefore be addressed. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  11. It's just as well kids don't vote: the positioning of children through public discourse around national testing

    Science.gov (United States)

    Lange, Troels; Meaney, Tamsin

    2014-06-01

    The importance of mathematics or its alter ego `numeracy' is being cemented in the public's mind with the instigation of national, high-stakes testing in Australia. Discussions about national testing in press releases, online news articles and online public comments tacitly attribute importance to mathematics. In these discussions, children are positioned as commodities, with mathematics achievement being the value that can be added to them. Deficit language identified some children as being less valuable commodities and less likely to gain value from schooling. In the same public discourse, the value of the sort of mathematics that can be assessed in these tests appeared to be so accepted that it did not need to be mentioned. This has social justice implications.

  12. Underground Test Area Fiscal Year 2013 Annual Quality Assurance Report Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Krenzien, Susan [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States); Marutzky, Sam [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States)

    2014-01-01

    This report is required by the Underground Test Area (UGTA) Quality Assurance Plan (QAP) and identifies the UGTA quality assurance (QA) activities for fiscal year (FY) 2013. All UGTA organizations—U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO); Desert Research Institute (DRI); Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); Navarro-Intera, LLC (N-I); National Security Technologies, LLC (NSTec); and the U.S. Geological Survey (USGS)—conducted QA activities in FY 2013. The activities included conducting assessments, identifying findings and completing corrective actions, evaluating laboratory performance, and publishing documents. In addition, integrated UGTA required reading and corrective action tracking was instituted.

  13. Underground Test Area Quality Assurance Project Plan Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Irene Farnham

    2011-05-01

    This Quality Assurance Project Plan (QAPP) provides the overall quality assurance (QA) program requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Underground Test Area (UGTA) Sub-Project (hereafter the Sub-Project) activities. The requirements in this QAPP are consistent with DOE Order 414.1C, Quality Assurance (DOE, 2005); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). The QAPP Revision 0 supersedes DOE--341, Underground Test Area Quality Assurance Project Plan, Nevada Test Site, Nevada, Revision 4.

  14. Action plan for the comprehensive nuclear-test-ban treaty (CTBT) Malaysian National Data Centre

    International Nuclear Information System (INIS)

    Bashillah Baharuddin; Alawiah Musa; Roslan Mohd Ali

    2007-01-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is a keystone of the international regime on the non-proliferation of nuclear weapons and an essential basis for the pursuit of nuclear disarmament. Its total ban of any nuclear weapon test explosion moreover will restrict the development and qualitative improvement of nuclear weapons and end the development of advanced new types of these weapons. One of the key features of this treaty is the development of an International Monitoring System (IMS) to detect any nuclear weapon test. The IMS comprises a network of 321 monitoring stations and 16 radionuclide laboratories that monitor the Earth for evidence of nuclear explosions. It uses four verification methods, including seismic, hydroacoustic and infrasound, in addition to radionuclide monitoring of the underground, underwater and atmosphere environments, respectively, whereas, radionuclide monitoring can detect radioactive debris vented from atmospheric, underground or underwater nuclear explosions. Malaysia signed the CTBT on 23 July 1998, and is currently in the process of drafting a national CTBT Act to facilitate ratification. As provided for under the Treaty, one of the radionuclide-monitoring stations (Rain) under the IMS will be located in Malaysia. The station is under the responsibility of the Malaysian Nuclear Agency, as the National Authority for the CTBT. The operation of the IMS is supported by an International Data Centre (IDC) CTBT, which is based at the headquarters of the Preparatory Commission for the CTBT Organization (CTBTO) in Vienna. To facilitate the acquisition of data from the IMS for the purposes of verifying compliance with the Treaty in general, and to enable Malaysia to benefit from the scientific applications of the data obtainable from the IDC, a CTBT National Data Centre (NDC) is the process of being established in Malaysia , which is targeted to be fully operational by the third quarter of 2007. (Author)

  15. 78 FR 35935 - National Institute for Occupational Health (NIOSH)-Certified B Readers; Training and Testing

    Science.gov (United States)

    2013-06-14

    ... training and certification program by developing digital- format training materials and examinations. Core...; Training and Testing AGENCY: National Institute for Occupational Safety and Health (NIOSH) of the Centers...: Request for information and comment on priority knowledge and competency items to address in training and...

  16. Large-Scale Testing and High-Fidelity Simulation Capabilities at Sandia National Laboratories to Support Space Power and Propulsion

    International Nuclear Information System (INIS)

    Dobranich, Dean; Blanchat, Thomas K.

    2008-01-01

    Sandia National Laboratories, as a Department of Energy, National Nuclear Security Agency, has major responsibility to ensure the safety and security needs of nuclear weapons. As such, with an experienced research staff, Sandia maintains a spectrum of modeling and simulation capabilities integrated with experimental and large-scale test capabilities. This expertise and these capabilities offer considerable resources for addressing issues of interest to the space power and propulsion communities. This paper presents Sandia's capability to perform thermal qualification (analysis, test, modeling and simulation) using a representative weapon system as an example demonstrating the potential to support NASA's Lunar Reactor System

  17. An overview of environment Canada's National Incinerator Testing and Evaluation Program (NITEP)

    International Nuclear Information System (INIS)

    Finkelstein, A.

    1991-01-01

    In response to the many concerns associated with incineration, Environment Canada established the National Incineration Testing and evaluation Program (NITEP) in 1984. It's mission was to assess the incineration process as a means for disposal of MSW in Canada. The program primarily focused on the environment and health impacts of MSW incinerators by determining how design and operating conditions can be modified to reduce emissions of concern. In addition to developing better measuring and monitoring methods, supporting ash residue management research programs, NITEP established four major field projects to develop the data base necessary for national guidelines. This paper presents a brief overview of the most significant field program findings over the past six years and the rationale for the Canadian Council of Ministers of the Environment (CCME) Operating and Emissions Guidelines for MSW Incinerators published in June of 1989. In addition an overview of the ash work completed to date, and work still underway, will be presented

  18. TEMPERATURE MONITORING OPTIONS AVAILABLE AT THE IDAHO NATIONAL LABORATORY ADVANCED TEST REACTOR

    Energy Technology Data Exchange (ETDEWEB)

    J.E. Daw; J.L. Rempe; D.L. Knudson; T. Unruh; B.M. Chase; K.L Davis

    2012-03-01

    As part of the Advanced Test Reactor National Scientific User Facility (ATR NSUF) program, the Idaho National Laboratory (INL) has developed in-house capabilities to fabricate, test, and qualify new and enhanced sensors for irradiation testing. To meet recent customer requests, an array of temperature monitoring options is now available to ATR users. The method selected is determined by test requirements and budget. Melt wires are the simplest and least expensive option for monitoring temperature. INL has recently verified the melting temperature of a collection of materials with melt temperatures ranging from 100 to 1000 C with a differential scanning calorimeter installed at INL’s High Temperature Test Laboratory (HTTL). INL encapsulates these melt wires in quartz or metal tubes. In the case of quartz tubes, multiple wires can be encapsulated in a single 1.6 mm diameter tube. The second option available to ATR users is a silicon carbide temperature monitor. The benefit of this option is that a single small monitor (typically 1 mm x 1 mm x 10 mm or 1 mm diameter x 10 mm length) can be used to detect peak irradiation temperatures ranging from 200 to 800 C. Equipment has been installed at INL’s HTTL to complete post-irradiation resistivity measurements on SiC monitors, a technique that has been found to yield the most accurate temperatures from these monitors. For instrumented tests, thermocouples may be used. In addition to Type-K and Type-N thermocouples, a High Temperature Irradiation Resistant ThermoCouple (HTIR-TC) was developed at the HTTL that contains commercially-available doped molybdenum paired with a niobium alloy thermoelements. Long duration high temperature tests, in furnaces and in the ATR and other MTRs, demonstrate that the HTIR-TC is accurate up to 1800 C and insensitive to thermal neutron interactions. Thus, degradation observed at temperatures above 1100 C with Type K and N thermocouples and decalibration due to transmutation with tungsten

  19. Underground Test Area Fiscal Year 2012 Annual Quality Assurance Report Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Farnham, Irene [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States); Marutzky, Sam [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States)

    2013-01-01

    This report is mandated by the Underground Test Area (UGTA) Quality Assurance Project Plan (QAPP) and identifies the UGTA quality assurance (QA) activities for fiscal year (FY) 2012. All UGTA organizations—U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO); Desert Research Institute (DRI); Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); Navarro-Intera, LLC (N-I); National Security Technologies, LLC (NSTec); and the U.S. Geological Survey (USGS)—conducted QA activities in FY 2012. The activities included conducting assessments, identifying findings and completing corrective actions, evaluating laboratory performance, revising the QAPP, and publishing documents. In addition, processes and procedures were developed to address deficiencies identified in the FY 2011 QAPP gap analysis.

  20. Efficacy of the National Football League-225 Test to Track Changes in One Repetition Maximum Bench Press After Training in National Collegiate Athletic Association Division IA Football Players.

    Science.gov (United States)

    Mann, J Bryan; Ivey, Pat A; Stoner, Josh D; Mayhew, Jerry L; Brechue, William F

    2015-11-01

    Numerous investigations have attested to the efficacy of the National Football League (NFL)-225 test to estimate one repetition maximum (1RM) bench press. However, no studies have assessed the efficacy of the test to track changes in strength across a training program. The purpose of this study was to determine the accuracy of the NFL-225 test for determining the change in 1RM bench press in National Collegiate Athletic Association Division IA college football players after training. Over a 4-year period, players (n = 203) were assessed before and after a 6-week off-season resistance program for 1RM bench press and repetitions completed with 102.3 kg (225 lbs). Test sessions typically occurred within 1 week of each other. Players significantly increased 1RM by 4.2 ± 8.6 kg and NFL-225 repetitions by 0.9 ± 2.3, although the effect size (ES) for each was trivial (ES = 0.03 and 0.07, respectively). National Football League 225 prediction equations had higher correlations with 1RM before training (intraclass correlation coefficient [ICC] = 0.95) than after training (ICC = 0.75). The correlation between the change in NFL-225 repetitions and change in 1RM was low and negative (r = -0.22, p bench press strength after short-term training.

  1. Report of test and research results on atomic energy obtained in national institutes in fiscal 1983

    International Nuclear Information System (INIS)

    1984-01-01

    As for the test and research on the utilization of atomic energy by national organizations, the budget was appropriated for the first time in fiscal year 1956. Since then, many valuable results of research have been produced in the diverse fields of nuclear fusion, safety research, food irradiation, medicine and others, in this way, the test and research have played large roles in the promotion of the utilization of atomic energy in Japan. This is the 24th report, in which the results of the test and research on the utilization of atomic energy carried out in fiscal year 1983 by national organizations are summarized. 5 researches on nuclear fusion, 19 researches on engineering safety and environmental radioactivity safety, 3 researches on food irradiation, 6 researches on the countermeasures to cancer, 19 researches on agriculture, forestry and fishery, 30 researches on medicine, pharmaceuticals and environmental hygiene, 6 researches on mining and industry, 6 researches on power reactors and nuclear ships, 1 research on agricultural water, 7 researches on activation analysis and 4 researches on injury prevention are reported. (Kako, I.)

  2. Factors prompting PSA-testing of asymptomatic men in a country with no guidelines: a national survey of general practitioners.

    LENUS (Irish Health Repository)

    Drummond, Frances J

    2009-01-01

    BACKGROUND: Increased use of prostate specific antigen (PSA) has been associated with increased prostate cancer incidence. Ireland is estimated to have one of the highest prostate cancer incidences in Europe and has no national guidelines for prostate cancer screening. GPs have a pivotal role in influencing PSA testing, therefore, our aim was to describe GP testing practices and to identify factors influencing these. METHODS: A postal survey, including questions on clinical practice and experience, knowledge and demographics was distributed to all GPs (n = 3,683). The main outcomes were (i) PSA testing asymptomatic men and (ii) "inappropriate" PSA testing, defined as testing asymptomatic men aged < 50 or > 75 years. Factors associated with these outcomes were identified using logistic regression. RESULTS: 1,625 GPs responded (response rate corrected for eligibility = 53%). Most respondents (79%) would PSA test asymptomatic men. Of these, 34% and 51% would test asymptomatic men < 50 and > 75 years, respectively. In multivariate analyses, GPs were more likely to test asymptomatic men if they were >or= 50 years, in practice >or= 10 years, female or less knowledgeable about PSA efficacy. Male GPs who would have a PSA test themselves were > 8-times more likely to PSA test asymptomatic men than GPs who would not have a test. GPs who had an asymptomatic patient diagnosed with prostate cancer following PSA testing, were > 3-times more likely to test asymptomatic men. Practice-related factors positively associated with testing included: running \\'well man\\' clinics, performing occupational health checks and performing other tests routinely with PSA. Factors positively associated with \\'inappropriate\\' testing included; being male and willing to have a PSA test, having worked\\/trained in the UK and supporting annual PSA testing. 91% of respondents supported the development of national PSA testing guidelines. CONCLUSION: Our findings suggest that widespread PSA testing

  3. NESHAP Annual Report for CY 2015 Sandia National Laboratories Tonopah Test Range

    Energy Technology Data Exchange (ETDEWEB)

    Evelo, Stacie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-05-01

    This National Emission Standards for Hazardous Air Pollutants (NESHAP) Annual Report has been prepared in a format to comply with the reporting requirements of 40 CFR 61.94 and the April 5, 1995 Memorandum of Agreement (MOA) between the Department of Energy (DOE) and the Environmental Protection Agency (EPA). According to the EPA approved NESHAP Monitoring Plan for the Tonopah Test Range (TTR), 40 CFR 61, subpart H, and the MOA, no additional monitoring or measurements are required at TTR in order to demonstrate compliance with the NESHAP regulation.

  4. On wake modeling, wind-farm gradients and AEP predictions at the Anholt wind farm

    DEFF Research Database (Denmark)

    Pena Diaz, Alfredo; Hansen, Kurt Schaldemose; Ott, Søren

    2017-01-01

    of the mesoscale simulations and supervisory control and data acquisition (SCADA), we show that for westerly flow in particular, there is a clear horizontal wind-speed gradient over the wind farm. We also use the mesoscale simulations to derive the undisturbed inflow conditions that are coupled with three commonly....... When looking at westerly flow wake cases, where the impact of the horizontal wind-speed gradient on the power of the undisturbed turbines is largest, the wake models agree with the SCADA fairly well; when looking at a southerly flow case, where the wake losses are highest, the wake models tend...... to underestimate the wake loss. With the mesoscale-wake model setup, we are also able to estimate the capacity factor of the wind farm rather well when compared to that derived from the SCADA. Finally, we estimate the uncertainty of the wake models by bootstrapping the SCADA. The models tend to underestimate...

  5. Reference Curves for Field Tests of Musculoskeletal Fitness in U.S. Children and Adolescents: The 2012 NHANES National Youth Fitness Survey.

    Science.gov (United States)

    Laurson, Kelly R; Saint-Maurice, Pedro F; Welk, Gregory J; Eisenmann, Joey C

    2017-08-01

    Laurson, KR, Saint-Maurice, PF, Welk, GJ, and Eisenmann, JC. Reference curves for field tests of musculoskeletal fitness in U.S. children and adolescents: The 2012 NHANES National Youth Fitness Survey. J Strength Cond Res 31(8): 2075-2082, 2017-The purpose of the study was to describe current levels of musculoskeletal fitness (MSF) in U.S. youth by creating nationally representative age-specific and sex-specific growth curves for handgrip strength (including relative and allometrically scaled handgrip), modified pull-ups, and the plank test. Participants in the National Youth Fitness Survey (n = 1,453) were tested on MSF, aerobic capacity (via submaximal treadmill test), and body composition (body mass index [BMI], waist circumference, and skinfolds). Using LMS regression, age-specific and sex-specific smoothed percentile curves of MSF were created and existing percentiles were used to assign age-specific and sex-specific z-scores for aerobic capacity and body composition. Correlation matrices were created to assess the relationships between z-scores on MSF, aerobic capacity, and body composition. At younger ages (3-10 years), boys scored higher than girls for handgrip strength and modified pull-ups, but not for the plank. By ages 13-15, differences between the boys and girls curves were more pronounced, with boys scoring higher on all tests. Correlations between tests of MSF and aerobic capacity were positive and low-to-moderate in strength. Correlations between tests of MSF and body composition were negative, excluding absolute handgrip strength, which was inversely related to other MSF tests and aerobic capacity but positively associated with body composition. The growth curves herein can be used as normative reference values or a starting point for creating health-related criterion reference standards for these tests. Comparisons with prior national surveys of physical fitness indicate that some components of MSF have likely decreased in the United States over

  6. A sandwich-designed temperature-gradient incubator for studies of microbial temperature responses

    DEFF Research Database (Denmark)

    Elsgaard, Lars; Jørgensen, L.W.

    2002-01-01

    of 28-ml test tubes. An electric plate heats one end of the TGI end and the other end is cooled by thermoelectric Peltier elements in combination with a liquid cooling system. The TGI is equipped with 24 calibrated Pt-100 temperature sensors and insulated by polyurethane plates. A PC-operated SCADA...

  7. Power of tests for comparing trend curves with application to national immunization survey (NIS).

    Science.gov (United States)

    Zhao, Zhen

    2011-02-28

    To develop statistical tests for comparing trend curves of study outcomes between two socio-demographic strata across consecutive time points, and compare statistical power of the proposed tests under different trend curves data, three statistical tests were proposed. For large sample size with independent normal assumption among strata and across consecutive time points, the Z and Chi-square test statistics were developed, which are functions of outcome estimates and the standard errors at each of the study time points for the two strata. For small sample size with independent normal assumption, the F-test statistic was generated, which is a function of sample size of the two strata and estimated parameters across study period. If two trend curves are approximately parallel, the power of Z-test is consistently higher than that of both Chi-square and F-test. If two trend curves cross at low interaction, the power of Z-test is higher than or equal to the power of both Chi-square and F-test; however, at high interaction, the powers of Chi-square and F-test are higher than that of Z-test. The measurement of interaction of two trend curves was defined. These tests were applied to the comparison of trend curves of vaccination coverage estimates of standard vaccine series with National Immunization Survey (NIS) 2000-2007 data. Copyright © 2011 John Wiley & Sons, Ltd.

  8. NNWSI waste from testing at Argonne National Laboratory. Semiannual report, July-December 1985

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.; Abrajano, T.A. Jr.; Ebert, W.

    1986-03-01

    The Nevada Nuclear Waste Storage Investigations (NNWSI) Project is investigating the volcanic tuff beds of Yucca Mountain, Nevada, as a potential location for a high-level radioactive waste repository. As part of the waste package development portion of this project, experiments are being performed by the Chemical Technology Division of Argonne National Laboratory to study the behavior of the waste forms under anticipated repository conditions. These experiments include (1) the development and performance of a test to measure waste form behavior in unsaturated conditions and (2) the performance of tests designed to study the behavior of waste package components in an irradiated environment. Previous reports document developments in these areas through 1984. This report summarizes progress in 1985. Reports will be issued semi-annually hereafter

  9. Development project of an automatic sampling system for part time unmanned pipeline terminals

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Gullherme O.; De Almelda, Marcio M. G.; Ramos, Ricardo R. [Petrobas, (Brazil); Potten, Gary [Cameron Measurement Systems, (United States)

    2010-07-01

    The Sao Paulo - Brasilia Pipeline (OSBRA) is a highly automated pipeline using a SCADA system which operates from a control room. A new quality management system standard was established for transportation and storage operations. The products had to be sampled on an automatic basis. This paper reports the development of an automatic sampling system (ASS) in accordance with the new quality control standard. The prototype was developed to be implemented through a human-machine interface (HMI) from the control room SCADA screens. A technical cooperation agreement(TCA) was drawn up for development of this new ASS product. The TCA was a joint cooperation between the Holding, the Operator and the cooperators. The prototype will be on-field tested at Senador Canedo tank farm to SPEC requirements. The current performance of the ASS establishes reasonable expectations for further successful development.

  10. Power Performance Verification of a Wind Farm Using the Friedman's Test.

    Science.gov (United States)

    Hernandez, Wilmar; López-Presa, José Luis; Maldonado-Correa, Jorge L

    2016-06-03

    In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman's test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable.

  11. On AEP prediction and wake modelling at Anholt

    DEFF Research Database (Denmark)

    Pena Diaz, Alfredo; Hansen, Kurt Schaldemose; Volker, Patrick

    and direction. We show that the WRF model is able to reproduce such gradients relatively well by comparison to the wind farm’s SCADA. About 1.5 yr of such SCADA, further quality controlled and filtered, reveals an average wake loss of 3.87% only, whereas results from three wake models, Park, Larsen and FUGA......, show average wake losses of 3.46%, 3.69%, and 3.38%, respectively. We employ a bootstrap method to estimate the uncertainty of the wake models. As this is performed with reference to the SCADA, the results provide an idea of the uncertainty of the AEP prediction2. We find all wake models...

  12. High-Reynolds Number Circulation Control Testing in the National Transonic Facility

    Science.gov (United States)

    Milholen, William E., II; Jones, Gregory S.; Chan, David T.; Goodliff, Scott L.

    2012-01-01

    A new capability to test active flow control concepts and propulsion simulations at high Reynolds numbers in the National Transonic Facility at the NASA Langley Research Center is being developed. The first active flow control experiment was completed using the new FAST-MAC semi-span model to study Reynolds number scaling effects for several circulation control concepts. Testing was conducted over a wide range of Mach numbers, up to chord Reynolds numbers of 30 million. The model was equipped with four onboard flow control valves allowing independent control of the circulation control plenums, which were directed over a 15% chord simple-hinged flap. Preliminary analysis of the uncorrected lift data showed that the circulation control increased the low-speed maximum lift coefficient by 33%. At transonic speeds, the circulation control was capable of positively altering the shockwave pattern on the upper wing surface and reducing flow separation. Furthermore, application of the technique to only the outboard portion of the wing demonstrated the feasibility of a pneumatic based roll control capability.

  13. Automated damage test facilities for materials development and production optic quality assurance at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Battersby, C.; Dickson, R.; Jennings, R.; Kimmons, J.; Kozlowski, M. R.; Maricle, S.; Mouser, R.; Runkel, M.; Schwartz, S.; Sheehan, L. M.; Weinzapfel, C.

    1998-01-01

    The Laser Program at LLNL has developed automated facilities for damage testing optics up to 1 meter in diameter. The systems were developed to characterize the statistical distribution of localized damage performance across large-aperture National Ignition Facility optics. Full aperture testing is a key component of the quality assurance program for several of the optical components. The primary damage testing methods used are R:1 mapping and raster scanning. Automation of these test methods was required to meet the optics manufacturing schedule. The automated activities include control and diagnosis of the damage-test laser beam as well as detection and characterization of damage events

  14. Hydrologic Source Term Processes and Models for the Clearwater and Wineskin Tests, Rainier Mesa, Nevada National Security Site

    Energy Technology Data Exchange (ETDEWEB)

    Carle, Steven F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2011-05-04

    This report describes the development, processes, and results of a hydrologic source term (HST) model for the CLEARWATER (U12q) and WINESKIN (U12r) tests located on Rainier Mesa, Nevada National Security Site, Nevada (Figure 1.1). Of the 61 underground tests (involving 62 unique detonations) conducted on Rainier Mesa (Area 12) between 1957 and 1992 (USDOE, 2015), the CLEARWATER and WINESKIN tests present many unique features that warrant a separate HST modeling effort from other Rainier Mesa tests.

  15. Detailed leak detection test plan and schedule for the Oak Ridge National Laboratory LLLW active tanks

    International Nuclear Information System (INIS)

    Douglas, D.G.; Maresca, J.W. Jr.

    1993-03-01

    This document provides a detailed leak detection test plan and schedule for leak testing many of the tanks that comprise the active portion of the liquid low-level waste (LLLW) system at the Oak Ridge National Laboratory (ORNL). This plan was prepared in response to the requirements of the Federal Facility Agreement (FFA) between the US Department of Energy (DOE) and two other agencies, the US Environmental Protection Agency (EPA) and the Tennessee Department of Environment and Conservation (TDEC)

  16. 75 FR 4134 - Pipeline Safety: Leak Detection on Hazardous Liquid Pipelines

    Science.gov (United States)

    2010-01-26

    ... safety study on pipeline Supervisory Control and Data Acquisition (SCADA) systems (NTSB/SS-05/02). The... indications of a leak on the SCADA interface was the impetus for this study. The NTSB examined 13 hazardous... pipelines, the line balance technique for leak detection can often be performed with manual calculations...

  17. Simulating coastal effects on an offshore wind farm

    DEFF Research Database (Denmark)

    van der Laan, Paul; Pena Diaz, Alfredo; Volker, Patrick

    the north-south oriented rows. This effect is visible in RANS, as plotted in Figure 1 and is also observed in SCADA data provided by DONG Energy. The wind resources at the wind farm and the power deficits, calculated by RANS, are compared with mesoscale simulations and SCADA data, respectively....

  18. An advanced automation system for operation of Sao Paulo pumping stations from TRANSPETRO Master Control Center - CNCO

    Energy Technology Data Exchange (ETDEWEB)

    Corcioli, Mario Sergio; Barreto, Camila Maria Benevenuto [TRANSPETRO, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    Since 2000 the operations of the TRANSPETRO pumping stations in the state of Sao Paulo region began to be transferred from local control centers located at the transfer and storage terminals to the National Operational Control Center (CNCO) of TRANSPETRO, located at the headquarters of the company, in Rio de Janeiro. The proposed paper aims to presenting an overview of the automation system that was developed to enable such pumping stations to be operated from CNCO in a reliable and secure manner, focusing on tools that offer an embedded system alarms completely free of false alarms with automatic determining of the root cause, and also automatic and advanced diagnoses of problems caused by failures of hardware, human error and abnormal conditions of the process, providing the CNCO SCADA system of accurate and quality information that help operators to make decisions. The referred automation system was integrated for the first time to CNCO SCADA system in 2000, for pipeline pumps of Osvat (Sao Sebastiao - Vale do Paraiba pipeline) station at the Sao Sebastiao Terminal - northern coast of Sao Paulo region. (author)

  19. Report of test and research results on atomic energy obtained in national institutes in fiscal 1985

    International Nuclear Information System (INIS)

    1986-01-01

    As for the test and research on the utilization of atomic energy in national institutes, the budget was appropriated for the first time in fiscal year 1956, and since then, the many valuable results of research have been obtained so far in the diversified fields of nuclear fusion, safety research, the irradiation of foods, medicine and others, thus the test and research accomplished the large role for promoting the utilization of atomic energy in Japan. In this report, the gists of the results of the test and research on the utilization of atomic energy carried out by national institutes in fiscal year 1985 are collected. No.1 of this report was published in 1960, and this is No.26. It is desired to increase the understanding about the recent trend and the results of the test and research on atomic energy utilization with this book. The researches on nuclear fusion, engineering safety and environmental radioactivity safety, the irradiation of foods, the countermeasures against cancer, fertilized soil, the quality improvement of brewing and farm products, the protection of farm products and the improvement of breeding, diagnosis and medical treatment, pharmaceuticals, environmental hygiene, the application to physiology and pathology, radiochemistry, radiation measurement, process analysis, nuclear reactor materials, nuclear powered ships, civil engineering, radioactivation analysis and injury prevention are reported. (Kako, I.)

  20. Power Performance Verification of a Wind Farm Using the Friedman’s Test

    Science.gov (United States)

    Hernandez, Wilmar; López-Presa, José Luis; Maldonado-Correa, Jorge L.

    2016-01-01

    In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman’s test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable. PMID:27271628

  1. Power Performance Verification of a Wind Farm Using the Friedman’s Test

    Directory of Open Access Journals (Sweden)

    Wilmar Hernandez

    2016-06-01

    Full Text Available In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman’s test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable.

  2. Underground Test Area Activity Communication/Interface Plan, Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Farnham, Irene [Navarro, Las Vegas, NV (United States); Rehfeldt, Kenneth [Navarro, Las Vegas, NV (United States)

    2016-10-01

    The purpose of this plan is to provide guidelines for effective communication and interfacing between Underground Test Area (UGTA) Activity participants, including the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) and its contractors. This plan specifically establishes the following: • UGTA mission, vision, and core values • Roles and responsibilities for key personnel • Communication with stakeholders • Guidance in key interface areas • Communication matrix

  3. Report of test and research results on atomic energy obtained in national institutes in fiscal 1986

    International Nuclear Information System (INIS)

    1988-01-01

    The test and research regarding the utilization of atomic energy carried out in national institutions have produced many valuable results in diverse fields so far, such as nuclear fusion, safety research, food irradiation and medicine, since the budget had been appropriated for the first time in 1956. It has accomplished large role in the promotion of atomic energy utilization in Japan. This report is volume 27, in which the results of the test and research on atomic energy utilization carried out by national institutions in fiscal year 1986 are summarized. It is hoped that the understanding about the recent trend and the results of the test and research on atomic energy utilization is further promoted by this report. The contents of this report are nuclear fusion; the research on engineering safety and environmental radioactivity safety; food irradiation; the countermeasures against cancer; fertilized soil, the improvement of quality, the protection of plants and the improvement of breeding in agriculture and fishery fields; diagnosis and medical treatment, pharmaceuticals, environmental hygiene and the application to physiology and pathology in medical field; radiation chemistry and radiation measurement in mining and industry fields; nuclear reactor materials and nuclear-powered ships; civil engineering; radioactivation analysis; and the research on the prevention of injuries. (Kako, I.)

  4. Report of test and research results on atomic energy obtained in national institutes in fiscal 1982

    International Nuclear Information System (INIS)

    1983-01-01

    As for the test and research on the utilization of atomic energy by national organizations, the budget was appropriated for the first time in fiscal year 1956. Since then, many valuable results of research have been produced in the diverse fields of nuclear fusion, safety research, food irradiation, medicine and others, in this way, the test and research have played large roles in the promotion of the utilization of atomic energy in Japan. This is the 23rd report, in which the results of the test and research on the utilization of atomic energy carried out in fiscal year 1982 by national organizations are summarized. 5 researches on nuclear fusion, 12 researches on engineering safety, 5 researches on environmental radioactivity safety, 3 researches on food irradiation, 5 researches on the countermeasures to cancer, 8 researches on soil fertilization, 4 researches on quality improvement, 7 researches on crop protection, 5 researches on the improvement of breeding, 8 researches on diagnosis and treatment, 8 researches on pharmaceuticals, 10 researches on the application to pathology, 6 researches on mining and industry, 6 researches on power reactors and nuclear ships, 1 research on underground water, 6 researches on activation analysis and 3 researches on injury prevention are reported. (Kako, I.)

  5. Report of test and research results on atomic energy obtained in national institutes in fiscal 1984

    International Nuclear Information System (INIS)

    1985-01-01

    The test and research regarding the utilization of atomic energy carried out in national institutions have produced many valuable results in diverse fields so far, such as nuclear fusion, safety research, food irradiation and medicine, since the budget had been appropriated for the first time in 1956. It has accomplished large role in the promotion of atomic energy utilization in Japan. This report is Volume 25, in which the results of the test and research on atomic energy utilization carried out by national institutions in fiscal year 1984 are summarized. It is hoped that the understanding about the recent trend and the results of the test and research on atomic energy utilization is further promoted by this report. The contents of this report are nuclear fusion; the research on engineering safety and environmental radioactivity safety; food irradiation; the countermeasures against cancer; fertilized soil, the improvement of quality, the protection of plants and the improvement of breeding in agriculture and fishery fields; diagnosis and medical treatment, pharmaceuticals, environmental hygiene and the application to physiology and pathology in medical field; radiation chemistry and radiation measurement in mining and industry fields; nuclear reactor materials and nuclear-powered ships; civil engineering; radioactivation analysis; and the research on the prevention of injuries. (Kako, I.)

  6. The Advanced Test Reactor National Scientific User Facility Advancing Nuclear Technology

    International Nuclear Information System (INIS)

    Allen, T.R.; Benson, J.B.; Foster, J.A.; Marshall, F.M.; Meyer, M.K.; Thelen, M.C.

    2009-01-01

    To help ensure the long-term viability of nuclear energy through a robust and sustained research and development effort, the U.S. Department of Energy (DOE) designated the Advanced Test Reactor and associated post-irradiation examination facilities a National Scientific User Facility (ATR NSUF), allowing broader access to nuclear energy researchers. The mission of the ATR NSUF is to provide access to world-class nuclear research facilities, thereby facilitating the advancement of nuclear science and technology. The ATR NSUF seeks to create an engaged academic and industrial user community that routinely conducts reactor-based research. Cost free access to the ATR and PIE facilities is granted based on technical merit to U.S. university-led experiment teams conducting non-proprietary research. Proposals are selected via independent technical peer review and relevance to DOE mission. Extensive publication of research results is expected as a condition for access. During FY 2008, the first full year of ATR NSUF operation, five university-led experiments were awarded access to the ATR and associated post-irradiation examination facilities. The ATR NSUF has awarded four new experiments in early FY 2009, and anticipates awarding additional experiments in the fall of 2009 as the results of the second 2009 proposal call. As the ATR NSUF program mature over the next two years, the capability to perform irradiation research of increasing complexity will become available. These capabilities include instrumented irradiation experiments and post-irradiation examinations on materials previously irradiated in U.S. reactor material test programs. The ATR critical facility will also be made available to researchers. An important component of the ATR NSUF an education program focused on the reactor-based tools available for resolving nuclear science and technology issues. The ATR NSUF provides education programs including a summer short course, internships, faculty-student team

  7. Heat leak testing of a superconducting RHIC dipole magnet at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    DeLalio, J.T.; Brown, D.P.; Sondericker, J.H.

    1993-01-01

    Brookhaven National Laboratory is currently performing heat load tests on a superconducting dipole magnet. The magnet is a prototype of the 360, 8 cm bore, arc dipole magnets that will be used in the Relativistic Heavy Ion Collider (RMC). An accurate measurement of the heat load is needed to eliminate cumulative errors when determining the REUC cryogenic system load requirements. The test setup consists of a dipole positioned between two quadrupoles in a common vacuum tank and heat shield. Piping and instrumentation are arranged to facilitate measurement of the heat load on the primary 4.6 K magnet load and the secondary 55 K heat shield load. Initial results suggest that the primary heat load is well below design allowances. The secondary load was found to be higher than estimated, but remained close to the budgeted amount. Overall, the dipole performed to specifications

  8. Underground Test Area (UGTA) Closure Report for Corrective Action Unit 98: Frenchman Flat Nevada National Security Site, Nevada, Revision 1 ROTC-1

    International Nuclear Information System (INIS)

    Farnham, Irene

    2016-01-01

    This Closure Report (CR) has been prepared for Corrective Action Unit (CAU) 98, Frenchman Flat, Nevada National Security Site (NNSS), Nevada. The Frenchman Flat CAU was the site of 10 underground nuclear tests, some of which have impacted groundwater near the tests. This work was performed as part of the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) Activity in accordance with the Federal Facility Agreement and Consent Order (FFACO). This CR describes the selected corrective action to be implemented during closure to protect human health and the environment from the impacted groundwater

  9. Underground Test Area (UGTA) Closure Report for Corrective Action Unit 98: Frenchman Flat Nevada National Security Site, Nevada, Revision 1 ROTC-1

    Energy Technology Data Exchange (ETDEWEB)

    Farnham, Irene [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States)

    2016-08-01

    This Closure Report (CR) has been prepared for Corrective Action Unit (CAU) 98, Frenchman Flat, Nevada National Security Site (NNSS), Nevada. The Frenchman Flat CAU was the site of 10 underground nuclear tests, some of which have impacted groundwater near the tests. This work was performed as part of the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) Activity in accordance with the Federal Facility Agreement and Consent Order (FFACO). This CR describes the selected corrective action to be implemented during closure to protect human health and the environment from the impacted groundwater

  10. European stress tests for nuclear power plants. The Swedish National Report

    International Nuclear Information System (INIS)

    2011-01-01

    On 11 March 2011, the Tohoku region in north Honshu, Japan, suffered a severe earthquake with an ensuing tsunami and an accident at the Fukushima Dai-ichi nuclear power plant. Due to the accident the Council of the European Union declared in late March that Member States were prepared to begin reviewing safety at nuclear facilities in the European Union by means of a comprehensive assessment of risk and safety ('stress testing'). On 25 May, SSM ordered the licensees of the nuclear power plants to conduct renewed analyses of the facilities' resilience against different kinds of natural phenomena. They were also to analyse how the facilities would be capable of dealing with a prolonged loss of electrical power, regardless of cause. On 31 October, the licensees reported on their stress tests to SSM. After reviewing these reports, SSM produced a summary stress test report, which was submitted to the Government on the 15 December. The present report is the national report on Swedish stress tests of nuclear power plants. The report will be submit to the European Commission no later than 31 December. Based on the review SSM has drawn the conclusion that the stress tests carried out by Swedish licensees are largely performed in accordance with the specification resolved within the European Union. The scope and depth of these analyses and assessments are essentially in accordance with ENSREG's definition of 'a comprehensive assessment of risk and safety'. The stress tests show that Swedish facilities are robust, but the tests also identify a number of opportunities to further strengthen the facilities' robustness. SSM will order the respective licensees to present an action plan for dealing with the results from the stress tests. The Authority will then examine the plans and adopt a standpoint on proposed measures as well as check that the necessary safety improvements are made. In a number of cases, the stress tests indicate deficiencies in relation to, or alternatively

  11. Public Awareness of Direct-to-Consumer Genetic Tests: Findings from the 2013 U.S. Health Information National Trends Survey.

    Science.gov (United States)

    Agurs-Collins, Tanya; Ferrer, Rebecca; Ottenbacher, Allison; Waters, Erika A; O'Connell, Mary E; Hamilton, Jada G

    2015-12-01

    Although the availability of direct-to-consumer (DTC) genetic testing has increased in recent years, the general public's awareness of this testing is not well understood. This study examined levels of public awareness of DTC genetic testing, sources of information about testing, and psychosocial factors associated with awareness of testing in the USA. Data were obtained from the nationally representative 2013 U.S. Health Information National Trends Survey. Guided by a social-cognitive conceptual framework, univariable and multivariable logistic regressions were conducted to identify factors associated with awareness of DTC genetic tests. Of 3185 participants, 35.6% were aware of DTC genetic tests, with the majority learning about these tests through radio, television, and the Internet. In the final adjusted model, participants with annual incomes of $99,999 or less had lower odds of being aware of DTC genetic testing (ORs ranging from 0.46-0.61) than did those participants with incomes of $100,000 or more. The odds of awareness of DTC genetic tests were significantly higher for those who actively seek cancer information (OR=1.91, 95% CI=1.36-2.69), use the Internet (OR=1.81, 95% CI=1.05-3.13), and have high numeracy skills (OR=1.67, 95% CI=1.17-2.38). It will be critical for healthcare researchers and practitioners to understand predictors and consequences of the public's awareness of DTC genetic tests, as well as how such awareness may translate into DTC genetic testing uptake, health behavior change, and ultimately disease prevention.

  12. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    Energy Technology Data Exchange (ETDEWEB)

    Plumb, Andrew A.; Taylor, Stuart A.; Halligan, Steve [University College London, Centre for Medical Imaging, Division of Medicine, London (United Kingdom); Ghanouni, Alex; Von Wagner, Christian [University College London, Health Behaviour Research Centre, Department of Epidemiology and Public Health, London (United Kingdom); Rees, Colin J. [Durham University School of Medicine, Pharmacy and Health, Durham (United Kingdom); Hewitson, Paul [University of Oxford, Health Services Research Unit, Nuffield Department of Population Health, Oxford (United Kingdom); Nickerson, Claire; Wright, Suzanne [Fulwood House, NHS Cancer Screening Programmes, Sheffield (United Kingdom)

    2017-03-15

    To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as complications. CTC and colonoscopy responses were compared using multilevel logistic regression. Of 67,114 subjects identified, 52,805 (79 %) responded. Understanding of test risks was lower for CTC (1712/1970 = 86.9 %) than colonoscopy (48783/50975 = 95.7 %, p < 0.0001). Overall, a slightly greater proportion of screenees found CTC unexpectedly uncomfortable (506/1970 = 25.7 %) than colonoscopy (10,705/50,975 = 21.0 %, p < 0.0001). CTC was tolerated well as a completion procedure for failed colonoscopy (unexpected discomfort; CTC = 26.3 %: colonoscopy = 57.0 %, p < 0.001). Post-procedural pain was equally common (CTC: 288/1970,14.6 %, colonoscopy: 7544/50,975,14.8 %; p = 0.55). Adverse event rates were similar in both groups (CTC: 20/2947 = 1.2 %; colonoscopy: 683/64,312 = 1.1 %), but generally less serious with CTC. Even though CTC was reserved for individuals either unsuitable for or unable to complete colonoscopy, we found only small differences in test-related discomfort. CTC was well tolerated as a completion procedure and was extremely safe. CTC can be delivered across a national screening programme with high patient satisfaction. (orig.)

  13. Argonne National Laboratory's photo-oxidation organic mixed waste treatment system - installation and startup testing

    International Nuclear Information System (INIS)

    Shearer, T.L.; Nelson, R.A.; Torres, T.; Conner, C.; Wygmans, D.

    1997-01-01

    This paper describes the installation and startup testing of the Argonne National Laboratory (ANL-E) Photo-Oxidation Organic Mixed Waste Treatment System. This system will treat organic mixed (i.e., radioactive and hazardous) waste by oxidizing the organics to carbon dioxide and inorganic salts in an aqueous media. The residue will be treated in the existing radwaste evaporators. The system is installed in the Waste Management Facility at the ANL-E site in Argonne, Illinois. 1 fig

  14. Analysis of trace neptunium in the vicinity of underground nuclear tests at the Nevada National Security Site.

    Science.gov (United States)

    Zhao, P; Tinnacher, R M; Zavarin, M; Kersting, A B

    2014-11-01

    A high sensitivity analytical method for (237)Np analysis was developed and applied to groundwater samples from the Nevada National Security Site (NNSS) using short-lived (239)Np as a yield tracer and HR magnetic sector ICP-MS. The (237)Np concentrations in the vicinity of the Almendro, Cambric, Dalhart, Cheshire, and Chancellor underground nuclear test locations range from nuclear tests at very low but measureable concentrations. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Uniformização de Dados de Subestações da Eletrosul

    Directory of Open Access Journals (Sweden)

    Gilberto Grandi

    2002-03-01

    Full Text Available Este artigo descreve a implantação de um projeto de aquisição de dados em Subestações (SE da ELETROSUL, denominado WEB-SCADA, tendo como premissa básica o seu gerenciamento através da WEB. A implantação deste projeto visa uniformizar em um único local, todos os dados dos equipamentos existentes em uma SE. Atualmente as informações estão dispersas, formando ilhas de dados. Para cada SE controladora (uma SE localizada geograficamente próxima a outras subestações existirá um servidor de banco de dados relacional baseado na arquitetura Linux, tendo por finalidade, armazenar as informações do Sistema de Supervisão, Controle e Aquisição de Dados (SCADA e dos Dispositivos Eletrônicos Inteligentes (IEDs. O projeto aqui concebido prevê o acesso a seus dados através de microcomputadores baseados em Windows conectados a Intranet corporativa da empresa. Através deles, os usuários poderão efetuar consultas aos dados a partir de qualquer local. Neste trabalho, descreve-se as fontes de dados das SEs, como surgem as ilhas de dados e comenta-se quais as vantagens que se obtém quando os dados estão integrados, bem como a arquitetura adotada de hardware, software e comunicação. Palavras Chaves: WEB-SCADA, E-SCADA, Telecontrole. ----------------------------------------------- ABSTRACT This paper describes the implantation of a project of data acquisition on a ELETROSUL substation (SE, named WEB-SCADA, having the main characteristic a WEB managing. The implementation of this project has the objective to standardize, all data from de equipments on the SE. Today the information is diffused, creating a data island. For which one controller SE (one SE nearly from others there will be a server with de relational database based on Linux architecture to store the information of the Supervisory, Control and Data Acquisition System (SCADA and the Intelligent Electronic Devices (IEDs. The project will have de access from the data through

  16. A summary of EPA radon chamber tests and results for rounds 3 and 4 of the National Radon Measurement Proficiency Program

    International Nuclear Information System (INIS)

    Smith, J.M.; Sensintaffar, E.L.

    1993-02-01

    The US Environmental Protection Agency's Office of Radiation and Indoor Air (ORIA) established the National Radon Measurement Proficiency (RMP) Program in 1986. Through this voluntary program, participants can demonstrate their ability to measure radon and/or radon decay products by submitting their detection devices to a blind test in a designated radon chamber. In this report, two EPA radon and radon decay products test chambers (chambers A and C) located at the National Air and Radiation Environmental Laboratory in Montgomery, Alabama are described. These chambers were used to expose detectors submitted for testing in Round 4 of the National Radon Measurement Proficiency Program and are used routinely for calibration purposes. Also described are the measurement and calibration procedures which were used to establish the official target values for radon and radon decay products concentrations during RMP Round 4 testing. The results for RMP Round 3 (conducted at the US DOE Environmental Measurements Laboratory radon chamber in New York) and RMP Round 4 (conducted in the two NAREL chambers) are discussed and compared. Following Round 4, the NAREL staff analyzed the collective performance for each measurement method tested in these rounds and found that all methods agreed with the target values within expected limits except for RPISU's and charcoal adsorbers. After analyzing the RMP4 results, NAREL staff spent several months evaluating the difference in charcoal adsorber response between Round 3 and 4 by performing radon chamber tests using EPA 4-inch, open-faced charcoal adsorbers

  17. Prenatal Testing for Adult-Onset Conditions: the Position of the National Society of Genetic Counselors.

    Science.gov (United States)

    Hercher, Laura; Uhlmann, Wendy R; Hoffman, Erin P; Gustafson, Shanna; Chen, Kelly M

    2016-12-01

    Advances in genetic testing and the availability of such testing in pregnancy allows prospective parents to test their future child for adult-onset conditions. This ability raises several complex ethical issues. Prospective parents have reproductive rights to obtain information about their fetus. This information may or may not alter pregnancy management. These rights can be in conflict with the rights of the future individual, who will be denied the right to elect or decline testing. This paper highlights the complexity of these issues, details discussions that went into the National Society of Genetic Counselors (NSGC) Public Policy Task Force's development of the Prenatal testing for Adult-Onset Conditions position statement adopted in November 2014, and cites relevant literature on this topic through December 2015. Issues addressed include parental rights and autonomy, rights of the future child, the right not to know, possible adverse effects on childhood and the need for genetic counseling. This paper will serve as a reference to genetic counselors and healthcare professionals when faced with this situation in clinical practice.

  18. Assessing the readiness of precision medicine interoperabilty: An exploratory study of the National Institutes of Health genetic testing registry.

    Science.gov (United States)

    Ronquillo, Jay G; Weng, Chunhua; Lester, William T

    2017-11-17

      Precision medicine involves three major innovations currently taking place in healthcare:  electronic health records, genomics, and big data.  A major challenge for healthcare providers, however, is understanding the readiness for practical application of initiatives like precision medicine.   To better understand the current state and challenges of precision medicine interoperability using a national genetic testing registry as a starting point, placed in the context of established interoperability formats.   We performed an exploratory analysis of the National Institutes of Health Genetic Testing Registry.  Relevant standards included Health Level Seven International Version 3 Implementation Guide for Family History, the Human Genome Organization Gene Nomenclature Committee (HGNC) database, and Systematized Nomenclature of Medicine - Clinical Terms (SNOMED CT).  We analyzed the distribution of genetic testing laboratories, genetic test characteristics, and standardized genome/clinical code mappings, stratified by laboratory setting. There were a total of 25472 genetic tests from 240 laboratories testing for approximately 3632 distinct genes.  Most tests focused on diagnosis, mutation confirmation, and/or risk assessment of germline mutations that could be passed to offspring.  Genes were successfully mapped to all HGNC identifiers, but less than half of tests mapped to SNOMED CT codes, highlighting significant gaps when linking genetic tests to standardized clinical codes that explain the medical motivations behind test ordering.  Conclusion:  While precision medicine could potentially transform healthcare, successful practical and clinical application will first require the comprehensive and responsible adoption of interoperable standards, terminologies, and formats across all aspects of the precision medicine pipeline.

  19. Assessing the readiness of precision medicine interoperabilty: An exploratory study of the National Institutes of Health genetic testing registry

    Directory of Open Access Journals (Sweden)

    Jay G Ronquillo

    2017-11-01

    Full Text Available Background:  Precision medicine involves three major innovations currently taking place in healthcare:  electronic health records, genomics, and big data.  A major challenge for healthcare providers, however, is understanding the readiness for practical application of initiatives like precision medicine. Objective:  To better understand the current state and challenges of precision medicine interoperability using a national genetic testing registry as a starting point, placed in the context of established interoperability formats. Methods:  We performed an exploratory analysis of the National Institutes of Health Genetic Testing Registry.  Relevant standards included Health Level Seven International Version 3 Implementation Guide for Family History, the Human Genome Organization Gene Nomenclature Committee (HGNC database, and Systematized Nomenclature of Medicine – Clinical Terms (SNOMED CT.  We analyzed the distribution of genetic testing laboratories, genetic test characteristics, and standardized genome/clinical code mappings, stratified by laboratory setting. Results: There were a total of 25472 genetic tests from 240 laboratories testing for approximately 3632 distinct genes.  Most tests focused on diagnosis, mutation confirmation, and/or risk assessment of germline mutations that could be passed to offspring.  Genes were successfully mapped to all HGNC identifiers, but less than half of tests mapped to SNOMED CT codes, highlighting significant gaps when linking genetic tests to standardized clinical codes that explain the medical motivations behind test ordering.   Conclusion:  While precision medicine could potentially transform healthcare, successful practical and clinical application will first require the comprehensive and responsible adoption of interoperable standards, terminologies, and formats across all aspects of the precision medicine pipeline.

  20. Comparative assay of fluorescent antibody test results among twelve European National Reference Laboratories using various anti-rabies conjugates

    DEFF Research Database (Denmark)

    Robardet, E.; Andrieu, S.; Rasmussen, Thomas Bruun

    2013-01-01

    Twelve National Reference Laboratories (NRLs) for rabies have undertaken a comparative assay to assess the comparison of fluorescent antibody test (FAT) results using five coded commercial anti-rabies conjugates (Biorad, Bioveta, Fujirebio, Millipore, and SIFIN conjugates). Homogenized positive...

  1. Use of Ground Penetrating Radar at the FAA's National Airport Pavement Test Facility

    Science.gov (United States)

    Injun, Song

    2015-04-01

    The Federal Aviation Administration (FAA) in the United States has used a ground-coupled Ground Penetrating Radar (GPR) at the National Airport Pavement Test Facility (NAPTF) since 2005. One of the primary objectives of the testing at the facility is to provide full-scale pavement response and failure information for use in airplane landing gear design and configuration studies. During the traffic testing at the facility, a GSSI GPR system was used to develop new procedures for monitoring Hot Mix Asphalt (HMA) pavement density changes that is directly related to pavement failure. After reviewing current setups for data acquisition software and procedures for identifying different pavement layers, dielectric constant and pavement thickness were selected as dominant parameters controlling HMA properties provided by GPR. A new methodology showing HMA density changes in terms of dielectric constant variations, called dielectric sweep test, was developed and applied in full-scale pavement test. The dielectric constant changes were successfully monitored with increasing airplane traffic numbers. The changes were compared to pavement performance data (permanent deformation). The measured dielectric constants based on the known HMA thicknesses were also compared with computed dielectric constants using an equation from ASTM D4748-98 Standard Test Method for Determining the Thickness of Bound Pavement Layers Using Short-Pulse Radar. Six inches diameter cylindrical cores were taken after construction and traffic testing for the HMA layer bulk specific gravity. The measured bulk specific gravity was also compared to monitor HMA density changes caused by aircraft traffic conditions. Additionally this presentation will review the applications of the FAA's ground-coupled GPR on embedded rebar identification in concrete pavement, sewer pipes in soil, and gage identifications in 3D plots.

  2. Sandia National Laboratories: Fabrication, Testing and Validation

    Science.gov (United States)

    digital and analog elements. * Cadence Process-Design Kit. Structured ASIC Sandia National Laboratories demonstrate complex multilevel devices such as micro-mass-analysis systems up to 25 microns thick and novel possible to fabricate a wide very large variety of useful devices. Micro-Mass-Analysis Systems Applications

  3. Cold test plan for the Old Hydrofracture Facility tank contents removal project, Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1997-11-01

    This Old Hydrofracture Facility (OHF) Tanks Contents Removal Project Cold Test Plan describes the activities to be conducted during the cold test of the OHF sluicing and pumping system at the Tank Technology Cold Test Facility (TTCTF). The TTCTF is located at the Robotics and Process Systems Complex at the Oak Ridge National Laboratory (ORNL). The cold test will demonstrate performance of the pumping and sluicing system, fine-tune operating instructions, and train the personnel in the actual work to be performed. After completion of the cold test a Technical Memorandum will be prepared documenting completion of the cold test, and the equipment will be relocated to the OHF site

  4. Report of test and research results on atomic energy obtained in national institutes in fiscal 1987

    International Nuclear Information System (INIS)

    1989-01-01

    The test and research regarding the utilization of atomic energy carried out in national institutions have produced many valuable results in diverse fields so far, such as nuclear fusion, safety research, food irradiation and medicine, since the budget had been appropriated for the first time in 1956. It has accomplished large role in the promotion of atomic energy utilization in Japan. This report is volume 28, in which the results of the test and research on atomic energy utilization carried out by national institutions in fiscal year 1987 are summarized. It is hoped that the understanding about the recent trend and the results of the test and research on atomic energy utilization is further promoted by this report. The contents of this report are nuclear fusion; the research on engineering safety and environmental radioactivity safety; food irradiation; the countermeasures against cancer; fertilized soil, the improvement of quality, the protection of plants and the improvement of breeding in agriculture and fishery fields; diagnosis and medical treatment, pharmaceuticals, environmental hygiene and the application to physiology and pathology in medical field; radiation measurement and process analysis in mining and industry fields; nuclear reactor materials and nuclear-powered ships; civil engineering; radioactivation analysis; the research on the prevention of injuries; and the basic researches on materials and acessment and reduction of irradiation risk. (J.P.N.)

  5. Risk Scan: A Review of Risk Assessment Capability and Maturity within the Canadian Safety and Security Program

    Science.gov (United States)

    2014-06-01

    SCADA / ICS Cyber Test Lab initiated in 2013 Psychosocial – academic research exists,; opportunity for sharing and developing impact assessment...ecosystems and species at risk), accidents / system failure (rail; pipelines ; ferries CSSP strategy for the North Focus on regional l(and local) problem...Guidance; business planning; environmental scan; proposal evaluation; and performance measurement Program Risk Management – Guidelines for project

  6. Testing and interfacing intelligent power supplies for the Los Alamos National Laboratory Accelerator Complex

    International Nuclear Information System (INIS)

    Sturrock, J.C.; Cohen, S.; Weintraub, B.L.; Hayden, D.J.; Archuleta, S.F.

    1992-01-01

    New high-current, high-precision microprocessor-controlled power supplies, built by Alpha Scientific Electronics of Hayward, CA, have been installed at the Los Alamos National Laboratory Accelerator Complex. Each unit has sophisticated microprocessor control on-board and communicates via RS-422 (serial communications). The units use a high level ASCII-based control protocol. Performance tests were conducted to verify adherence to specification and to ascertain ultimate long-term stability. The ''front-end'' software used by the accelerator control system has been written to accommodate these new devices. The supplies are interfaced to the control system through a terminal server port connected to the site-wide ediernet backbone. Test design and results as well as details of the software implementation for the analog and digital control of the supplies through the accelerator control system are presented

  7. Assessing stakeholder perceptions of the acceptability and feasibility of national scale-up for a dual HIV/syphilis rapid diagnostic test in Malawi.

    Science.gov (United States)

    Maddox, Brandy L Peterson; Wright, Shauntā S; Namadingo, Hazel; Bowen, Virginia B; Chipungu, Geoffrey A; Kamb, Mary L

    2017-12-01

    The WHO recommends pregnant women receive both HIV and syphilis testing at their first antenatal care visit, as untreated maternal infections can lead to severe, adverse pregnancy outcomes. One strategy for increasing testing for both HIV and syphilis is the use of point-of-care (rapid) diagnostic tests that are simple, proven effective and inexpensive. In Malawi, pregnant women routinely receive HIV testing, but only 10% are tested for syphilis at their first antenatal care visit. This evaluation explores stakeholder perceptions of a novel, dual HIV/syphilis rapid diagnostic test and potential barriers to national scale-up of the dual test in Malawi. During June and July 2015, we conducted 15 semistructured interviews with 25 healthcare workers, laboratorians, Ministry of Health leaders and partner agency representatives working in prevention of mother-to-child transmission in Malawi. We asked stakeholders about the importance of a dual rapid diagnostic test, concerns using and procuring the dual test and recommendations for national expansion. Stakeholders viewed the test favourably, citing the importance of a dual rapid test in preventing missed opportunities for syphilis diagnosis and treatment, improving infant outcomes and increasing syphilis testing coverage. Primary technical concerns were about the additional procedural steps needed to perform the test, the possibility that testers may not adhere to required waiting times before interpreting results and difficulty reading and interpreting test results. Stakeholders thought national scale-up would require demonstration of cost-savings, uniform coordination, revisions to testing guidelines and algorithms, training of testers and a reliable supply chain. Stakeholders largely support implementation of a dual HIV/syphilis rapid diagnostic test as a feasible alternative to current antenatal testing. Scale-up will require addressing perceived barriers; negotiating changes to existing algorithms and guidelines

  8. Impacts Analyses Supporting the National Environmental Policy Act Environmental Assessment for the Resumption of Transient Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, Annette L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Brown, LLoyd C. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Carathers, David C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Christensen, Boyd D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Dahl, James J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Miller, Mark L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Farnum, Cathy Ottinger [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Peterson, Steven [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sondrup, A. Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States); Subaiya, Peter V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wachs, Daniel M. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Weiner, Ruth F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-02-01

    This document contains the analysis details and summary of analyses conducted to evaluate the environmental impacts for the Resumption of Transient Fuel and Materials Testing Program. It provides an assessment of the impacts for the two action alternatives being evaluated in the environmental assessment. These alternatives are (1) resumption of transient testing using the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL) and (2) conducting transient testing using the Annular Core Research Reactor (ACRR) at Sandia National Laboratory in New Mexico (SNL/NM). Analyses are provided for radiologic emissions, other air emissions, soil contamination, and groundwater contamination that could occur (1) during normal operations, (2) as a result of accidents in one of the facilities, and (3) during transport. It does not include an assessment of the biotic, cultural resources, waste generation, or other impacts that could result from the resumption of transient testing. Analyses were conducted by technical professionals at INL and SNL/NM as noted throughout this report. The analyses are based on bounding radionuclide inventories, with the same inventories used for test materials by both alternatives and different inventories for the TREAT Reactor and ACRR. An upper value on the number of tests was assumed, with a test frequency determined by the realistic turn-around times required between experiments. The estimates provided for impacts during normal operations are based on historical emission rates and projected usage rates; therefore, they are bounding. Estimated doses for members of the public, collocated workers, and facility workers that could be incurred as a result of an accident are very conservative. They do not credit safety systems or administrative procedures (such as evacuation plans or use of personal protective equipment) that could be used to limit worker doses. Doses estimated for transportation are conservative and are based on

  9. Day-Ahead Wind Power Forecasting Using a Two-Stage Hybrid Modeling Approach Based on SCADA and Meteorological Information, and Evaluating the Impact of Input-Data Dependency on Forecasting Accuracy

    Directory of Open Access Journals (Sweden)

    Dehua Zheng

    2017-12-01

    Full Text Available The power generated by wind generators is usually associated with uncertainties, due to the intermittency of wind speed and other weather variables. This creates a big challenge for transmission system operators (TSOs and distribution system operators (DSOs in terms of connecting, controlling and managing power networks with high-penetration wind energy. Hence, in these power networks, accurate wind power forecasts are essential for their reliable and efficient operation. They support TSOs and DSOs in enhancing the control and management of the power network. In this paper, a novel two-stage hybrid approach based on the combination of the Hilbert-Huang transform (HHT, genetic algorithm (GA and artificial neural network (ANN is proposed for day-ahead wind power forecasting. The approach is composed of two stages. The first stage utilizes numerical weather prediction (NWP meteorological information to predict wind speed at the exact site of the wind farm. The second stage maps actual wind speed vs. power characteristics recorded by SCADA. Then, the wind speed forecast in the first stage for the future day is fed to the second stage to predict the future day’s wind power. Comparative selection of input-data parameter sets for the forecasting model and impact analysis of input-data dependency on forecasting accuracy have also been studied. The proposed approach achieves significant forecasting accuracy improvement compared with three other artificial intelligence-based forecasting approaches and a benchmark model using the smart persistence method.

  10. DESIGN CHARACTERISTICS OF THE IDAHO NATIONAL LABORATORY HIGH-[TEMPERATURE GAS-COOLED TEST REACTOR

    Energy Technology Data Exchange (ETDEWEB)

    Sterbentz, James; Bayless, Paul; Strydom, Gerhard; Kumar, Akansha; Gougar, Hans

    2016-11-01

    A point design for a graphite-moderated, high-temperature, gas-cooled test reactor (HTG TR) has been developed by Idaho National Laboratory (INL) as part of a United States (U.S.) Department of Energy (DOE) initiative to explore and potentially expand the existing U.S. test reactor capabilities. This paper provides a summary of the design and its main attributes. The 200 MW HTG TR is a thermal-neutron spectrum reactor composed of hexagonal prismatic fuel and graphite reflector blocks. Twelve fuel columns (96 fuel blocks total and 6.34 m active core height) are arranged in two hexagonal rings to form a relatively compact, high-power density, annular core sandwiched between inner, outer, top, and bottom graphite reflectors. The HTG-TR is designed to operate at 7 MPa with a coolant inlet/outlet temperature of 325°C/650°C, and utilizes TRISO particle fuel from the DOE AGR Program with 425 ?m uranium oxycarbide (UCO) kernels and an enrichment of 15.5 wt% 235U. The primary mission of the HTG TR is material irradiation and therefore the core has been specifically designed and optimized to provide the highest possible thermal and fast neutron fluxes. The highest thermal neutron flux (3.90E+14 n/cm2s) occurs in the outer reflector, and the maximum fast flux levels (1.17E+14 n/cm2s) are produced in the central reflector column where most of the graphite has been removed. Due to high core temperatures under accident conditions, all the irradiation test facilities have been located in the inner and outer reflectors where fast flux levels decline. The core features a large number of irradiation positions with large test volumes and long test lengths, ideal for thermal neutron irradiation of large test articles. The total available test volume is more than 1100 liters. Up to four test loop facilities can be accommodated with pressure tube boundaries to isolate test articles and test fluids (e.g., liquid metal, liquid salt, light water) from the helium primary coolant system.

  11. Risk factor assessment to anticipate performance in the National Developmental Screening Test in children from a disadvantaged area.

    Science.gov (United States)

    Montes, Alejandro; Pazos, Gustavo

    2016-02-01

    Identifying children at risk of failing the National Developmental Screening Test by combining prevalences of children suspected of having inapparent developmental disorders (IDDs) and associated risk factors (RFs) would allow to save resources. 1. To estimate the prevalence of children suspected of having IDDs. 2. To identify associated RFs. 3. To assess three methods developed based on observed RFs and propose a pre-screening procedure. The National Developmental Screening Test was administered to 60 randomly selected children aged between 2 and 4 years old from a socioeconomically disadvantaged area from Puerto Madryn. Twenty-four biological and socioenvironmental outcome measures were assessed in order to identify potential RFs using bivariate and multivariate analyses. The likelihood of failing the screening test was estimated as follows: 1. a multivariate logistic regression model was developed; 2. a relationship was established between the number of RFs present in each child and the percentage of children who failed the test; 3. these two methods were combined. The prevalence of children suspected of having IDDs was 55.0% (95% confidence interval: 42.4%-67.6%). Six RFs were initially identified using the bivariate approach. Three of them (maternal education, number of health checkups and Z scores for height-for-age, and maternal age) were included in the logistic regression model, which has a greater explanatory power. The third method included in the assessment showed greater sensitivity and specificity (85% and 79%, respectively). The estimated prevalence of children suspected of having IDDs was four times higher than the national standards. Seven RFs were identified. Combining the analysis of risk factor accumulation and a multivariate model provides a firm basis for developing a sensitive, specific and practical pre-screening procedure for socioeconomically disadvantaged areas. Sociedad Argentina de Pediatría.

  12. The relationships between pesticide metabolites and neurobehavioral test performance in the third National Health and Nutrition Examination Survey.

    Science.gov (United States)

    Krieg, Edward F

    2013-01-01

    Regression analysis was used to estimate and test for relationships between urinary pesticide metabolites and neurobehavioral test performance in adults, 20 to 59 years old, participating in the third National Health and Nutrition Examination Survey. The 12 pesticide metabolites included 2 naphthols, 8 phenols, a phenoxyacetic acid, and a pyridinol. The 3 neurobehavioral tests included in the survey were simple reaction time, symbol-digit substitution, and serial digit learning. As the 2,4-dichlorophenol, 2,5-dichlorophenol, and the pentachlorophenol concentrations increased, performance on the serial digit learning test improved. As the 2,5-dichlorophenol concentration increased, performance on the symbol-digit substitution test improved. At low concentrations, the parent compounds of these metabolites may act at acetylcholine and γ-aminobutyric acid synapses in the central nervous system to improve neurobehavioral test performance.

  13. Database dictionary for the results of groundwater tracer tests using tritiated water, conducted at the Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, B.K. [Univ. of Tennessee, Knoxville, TN (United States). Dept. of Civil Engineering; Huff, D.D. [Oak Ridge National Lab., TN (United States). Environmental Sciences Div.

    1997-05-01

    In 1977, the United States Geological Survey (USGS) conducted two tracer tests at the Oak Ridge National Laboratory (ORNL) using tritiated water to study the relative importance of bedding-plane openings on shallow groundwater flow. Through a cooperative agreement between the USGS and the US Department of Energy (DOE), the data were made available to researchers at the Oak Ridge National Laboratory (ORNL), who organized the data into a data management format. The results of these groundwater tracer tests have been compiled into a collection of four SAS data sets. This report documents these SAS data sets, including their structure, methodology, and content. The SAS data sets include information on precipitation, tritium, water levels, and well construction for wells at or near ORNL radioactive waste burial grounds 4, 5, and 6.

  14. Preliminary Report on Oak Ridge National Laboratory Testing of Drake/ACSS/MA2/E3X

    Energy Technology Data Exchange (ETDEWEB)

    Irminger, Philip [ORNL; Davis, Cody [General Cable Corporation; Temple, Bill [General Cable Corporation; Baker, Gord [General Cable Corporation; Starke, Michael R [ORNL

    2016-01-01

    A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of a new conductor technology under real world conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr with E3X Technology a standard overhead conductor with an inorganic high emissivity, low absorptivity surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across a wide range of operating temperatures, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides initial results of that testing.

  15. Testing the status-legitimacy hypothesis: A multilevel modeling approach to the perception of legitimacy in income distribution in 36 nations.

    Science.gov (United States)

    Caricati, Luca

    2017-01-01

    The status-legitimacy hypothesis was tested by analyzing cross-national data about social inequality. Several indicators were used as indexes of social advantage: social class, personal income, and self-position in the social hierarchy. Moreover, inequality and freedom in nations, as indexed by Gini and by the human freedom index, were considered. Results from 36 nations worldwide showed no support for the status-legitimacy hypothesis. The perception that income distribution was fair tended to increase as social advantage increased. Moreover, national context increased the difference between advantaged and disadvantaged people in the perception of social fairness: Contrary to the status-legitimacy hypothesis, disadvantaged people were more likely than advantaged people to perceive income distribution as too large, and this difference increased in nations with greater freedom and equality. The implications for the status-legitimacy hypothesis are discussed.

  16. Evaluation of the Standard Setting on the 2005 Grade 12 National Assessment of Educational Progress Mathematics Test

    Science.gov (United States)

    Sireci, Stephen G.; Hauger, Jeffrey B.; Wells, Craig S.; Shea, Christine; Zenisky, April L.

    2009-01-01

    The National Assessment Governing Board used a new method to set achievement level standards on the 2005 Grade 12 NAEP Math test. In this article, we summarize our independent evaluation of the process used to set these standards. The evaluation data included observations of the standard-setting meeting, observations of advisory committee meetings…

  17. Examining Cybersecurity of Cyberphysical Systems for Critical Infrastructures Through Work Domain Analysis.

    Science.gov (United States)

    Wang, Hao; Lau, Nathan; Gerdes, Ryan M

    2018-04-01

    The aim of this study was to apply work domain analysis for cybersecurity assessment and design of supervisory control and data acquisition (SCADA) systems. Adoption of information and communication technology in cyberphysical systems (CPSs) for critical infrastructures enables automated and distributed control but introduces cybersecurity risk. Many CPSs employ SCADA industrial control systems that have become the target of cyberattacks, which inflict physical damage without use of force. Given that absolute security is not feasible for complex systems, cyberintrusions that introduce unanticipated events will occur; a proper response will in turn require human adaptive ability. Therefore, analysis techniques that can support security assessment and human factors engineering are invaluable for defending CPSs. We conducted work domain analysis using the abstraction hierarchy (AH) to model a generic SCADA implementation to identify the functional structures and means-ends relations. We then adopted a case study approach examining the Stuxnet cyberattack by developing and integrating AHs for the uranium enrichment process, SCADA implementation, and malware to investigate the interactions between the three aspects of cybersecurity in CPSs. The AHs for modeling a generic SCADA implementation and studying the Stuxnet cyberattack are useful for mapping attack vectors, identifying deficiencies in security processes and features, and evaluating proposed security solutions with respect to system objectives. Work domain analysis is an effective analytical method for studying cybersecurity of CPSs for critical infrastructures in a psychologically relevant manner. Work domain analysis should be applied to assess cybersecurity risk and inform engineering and user interface design.

  18. An assessment of Microtox trademark as a biomonitoring tool for whole effluent testing for Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Zachritz, W.H. II; Morrow, J.

    1994-01-01

    Los Alamos National Laboratory (LANL) has special discharge problems relating to potential radioactive content of the effluent discharge waters. Because of this all testing must be performed on-site and results must be rapidly determined. There is a need to examine the development of a real-time procedure for effluent biomonitoring to met these site limitations. The Microtox trademark unit for toxicity testing is a microbially-based test system that shows great promise to be used for WET testing. The overall goal of this study is to develop an acceptable protocol for operational biomonitoring using the Microtox trademark toxicity test for LANL. The specific objectives include: development of an appropriate toxicity testing protocol using the Microtox trademark toxicity test for whole effluent toxicity testing and evaluation of the protocol based on factors such as sensitivity, response time, cost of analysis, and simplicity of operation

  19. BASHH 2016 UK national audit and survey of HIV testing, risk assessment and follow-up: case note audit.

    Science.gov (United States)

    Bhaduri, Sumit; Curtis, Hilary; McClean, Hugo; Sullivan, Ann K

    2018-01-01

    This national audit demonstrated discrepancies between actual practice and that indicated by clinic policies following enquiry about alcohol, recreational drugs and chemsex use. Clinics were more likely to enquire about risk behaviour if this was clinic policy or routine practice. Previous testing was the most common reason for refusing HIV testing, although 33% of men who have sex with men had a prior test of more than three months ago. Of the group declining due to recent exposure in the window period, 21/119 cases had an exposure within the four weeks prior to presentation, but had a previous risk not covered by previous testing. Recommendations include provision of risk assessments for alcohol, recreational drug use and chemsex, documenting reasons for HIV test refusal, provision of HIV point-of-care testing, follow-up for cases at higher risk of HIV and advice about community testing or self-sampling/testing.

  20. CYBER WARFARE GOVERNANCE: EVALUATION OF CURRENT INTERNATIONAL AGREEMENTS ON THE OFFENSIVE USE OF CYBER

    Science.gov (United States)

    2015-10-01

    STUXNET instead targeted programmable logic controllers, which are devices that interact directly with machinery or hardware in order for them to...vulnerability in networks across the world as supervisory control and data acquisition ( SCADA ) systems, similar to the ones attacked in Iran, are...used worldwide to perform tasks such as traffic control, managing power grids and management of other utility systems. The heavy reliance on SCADA

  1. Performance Comparison of BPL, EtherLoop and SHDSL technology performance on existing pilot cable circuits under the presence of induced voltage

    International Nuclear Information System (INIS)

    Che, Y X; Ong, H S; Lai, L C; Ong, X J; Do, N Q; Karuppiah, S

    2013-01-01

    Pilot cable is originally used for utility protection. Then, pilot cable is further utilized for SCADA communication with low frequency PSK modem in the early 1990. However, the quality of pilot cable communication drops recently. Pilot cable starts to deteriorate due to aging and other unknown factors. It is also believed that the presence of induced voltage causes interference to existing modem communication which operates at low frequency channel. Therefore, BPL (Broadband Power Line), EtherLoop and SHDSL (Symmetrical High-speed Digital Subscriber Line) modem technology are proposed as alternative communication solutions for pilot cable communication. The performance of the 3 selected technologies on existing pilot cable circuits under the presence of induced voltage are measured and compared. Total of 11 pilot circuits with different length and level of induced voltage influence are selected for modem testing. The performance of BPL, EtherLoop and SHDSL modem technology are measured by the delay, bandwidth, packet loss and the long term usability SCADA (Supervisory Control and Data Acquisition) application. The testing results are presented and discussed in this paper. The results show that the 3 selected technologies are dependent on distance and independent on the level of induced voltage.

  2. An ethernet/IP security review with intrusion detection applications

    International Nuclear Information System (INIS)

    Laughter, S. A.; Williams, R. D.

    2006-01-01

    Supervisory Control and Data Acquisition (SCADA) and automation networks, used throughout utility and manufacturing applications, have their own specific set of operational and security requirements when compared to corporate networks. The modern climate of heightened national security and awareness of terrorist threats has made the security of these systems of prime concern. There is a need to understand the vulnerabilities of these systems and how to monitor and protect them. Ethernet/IP is a member of a family of protocols based on the Control and Information Protocol (CIP). Ethernet/IP allows automation systems to be utilized on and integrated with traditional TCP/IP networks, facilitating integration of these networks with corporate systems and even the Internet. A review of the CIP protocol and the additions Ethernet/IP makes to it has been done to reveal the kind of attacks made possible through the protocol. A set of rules for the SNORT Intrusion Detection software is developed based on the results of the security review. These can be used to monitor, and possibly actively protect, a SCADA or automation network that utilizes Ethernet/IP in its infrastructure. (authors)

  3. Cyber Security on Nuclear Power Plant's Computer Systems

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ick Hyun [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2010-10-15

    Computer systems are used in many different fields of industry. Most of us are taking great advantages from the computer systems. Because of the effectiveness and great performance of computer system, we are getting so dependable on the computer. But the more we are dependable on the computer system, the more the risk we will face when the computer system is unavailable or inaccessible or uncontrollable. There are SCADA, Supervisory Control And Data Acquisition, system which are broadly used for critical infrastructure such as transportation, electricity, water management. And if the SCADA system is vulnerable to the cyber attack, it is going to be nation's big disaster. Especially if nuclear power plant's main control systems are attacked by cyber terrorists, the results may be huge. Leaking of radioactive material will be the terrorist's main purpose without using physical forces. In this paper, different types of cyber attacks are described, and a possible structure of NPP's computer network system is presented. And the paper also provides possible ways of destruction of the NPP's computer system along with some suggestions for the protection against cyber attacks

  4. Cyber Security on Nuclear Power Plant's Computer Systems

    International Nuclear Information System (INIS)

    Shin, Ick Hyun

    2010-01-01

    Computer systems are used in many different fields of industry. Most of us are taking great advantages from the computer systems. Because of the effectiveness and great performance of computer system, we are getting so dependable on the computer. But the more we are dependable on the computer system, the more the risk we will face when the computer system is unavailable or inaccessible or uncontrollable. There are SCADA, Supervisory Control And Data Acquisition, system which are broadly used for critical infrastructure such as transportation, electricity, water management. And if the SCADA system is vulnerable to the cyber attack, it is going to be nation's big disaster. Especially if nuclear power plant's main control systems are attacked by cyber terrorists, the results may be huge. Leaking of radioactive material will be the terrorist's main purpose without using physical forces. In this paper, different types of cyber attacks are described, and a possible structure of NPP's computer network system is presented. And the paper also provides possible ways of destruction of the NPP's computer system along with some suggestions for the protection against cyber attacks

  5. Network SCADA System

    International Nuclear Information System (INIS)

    Milivojevic, Dragan R.; Tasic, Visa; Karabasevic, Dejan

    2003-01-01

    Copper Institute, Industrial Informatics department, is developing and applying network real time process monitoring and control systems. Some of these systems are already in use. The paper presents some hardware and software general remarks and performances, with special regard to communication sub-systems and network possibilities. (Author)

  6. Monitoring HIV Testing in the United States: Consequences of Methodology Changes to National Surveys.

    Directory of Open Access Journals (Sweden)

    Michelle M Van Handel

    Full Text Available In 2011, the National Health Interview Survey (NHIS, an in-person household interview, revised the human immunodeficiency virus (HIV section of the survey and the Behavioral Risk Factor Surveillance System (BRFSS, a telephone-based survey, added cellphone numbers to its sampling frame. We sought to determine how these changes might affect assessment of HIV testing trends.We used linear regression with pairwise contrasts with 2003-2013 data from NHIS and BRFSS to compare percentages of persons aged 18-64 years who reported HIV testing in landline versus cellphone-only households before and after 2011, when NHIS revised its in-person questionnaire and BRFSS added cellphone numbers to its telephone-based sample.In NHIS, the percentage of persons in cellphone-only households increased 13-fold from 2003 to 2013. The percentage ever tested for HIV was 6%-10% higher among persons in cellphone-only than landline households. The percentage ever tested for HIV increased significantly from 40.2% in 2003 to 45.0% in 2010, but was significantly lower in 2011 (40.6% and 2012 (39.7%. In BRFSS, the percentage ever tested decreased significantly from 45.9% in 2003 to 40.2% in 2010, but increased to 42.9% in 2011 and 43.5% in 2013.HIV testing estimates were lower after NHIS questionnaire changes but higher after BRFSS methodology changes. Data before and after 2011 are not comparable, complicating assessment of trends.

  7. Examining Innovative Divertor and Main Chamber Options for a National Divertor Test Tokamak

    Science.gov (United States)

    Labombard, B.; Umansky, M.; Brunner, D.; Kuang, A. Q.; Marmar, E.; Wallace, G.; Whyte, D.; Wukitch, S.

    2016-10-01

    The US fusion community has identified a compelling need for a National Divertor Test Tokamak. The 2015 Community Planning Workshop on PMI called for a national working group to develop options. Important elements of a NDTT, adopted from the ADX concept, include the ability to explore long-leg divertor `solutions for power exhaust and particle control' (Priority Research Direction B) and to employ inside-launch RF actuators combined with double-null topologies as `plasma solution for main chamber wall components, including tools for controllable sustained operation' (PRD-C). Here we examine new information on these ideas. The projected performance of super-X and X-point target long-leg divertors is looking very promising; a stable fully-detached divertor condition handling an order-of-magnitude increase in power handling over conventional divertors may be possible. New experiments on Alcator C-Mod are addressing issues of high-field side versus low-field side heat flux sharing in double-null topologies and the screening of impurities that might originate from RF actuators placed in the high-field side - both with favorable results. Supported by USDoE Awards DE-FC02-99ER54512 and DE-AC52-07NA27344.

  8. Spent fuel storage cask testing and operational experience at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Eslinger, L.E.; Schmitt, R.C.

    1989-01-01

    Spent-fuel storage cask research, development, and demonstration activities are being performed for the U.S. Department of Energy's (DOE's) Office of Civilian Radioactive Waste Management (OCRWM) as a part of the storage cask testing program. The cask testing program at federal sites and other locations supports the Nuclear Waste Policy Act (NWPA) and DOE objectives for cooperative demonstrations with the cask vendors and utilities for development of at-reactor dry cask storage capabilities for spent nuclear fuel assemblies. One research and development program for the storage cask performance testing of metal storage cask was initiated through a cooperative agreement between Virginia Power and DOE in 1984. The performance testing was conducted for the DOE and the Electric Power Research Institute by the Pacific Northwest laboratory, operated for DOE by Battelle Memorial Institute, and the Idaho National Engineering Laboratory (INEL), operated for DOE by EG ampersand G Idaho, Inc. In 1988 a cooperative agreement was entered into by DOE with Pacific Sierra Nuclear Associates (PSN) for performance testing of the PSN concrete Ventilated Storage Cask. Another closely related activity involving INEL is a transportable storage cask project identified as the Nuclear Fuel Services Spent-Fuel Shipping/Storage Cask Demonstration Project. The purpose of this project is to demonstrate the feasibility of packing, transporting, and storing commercial spent fuel in dual-purpose transport/storage casks

  9. The advanced test reactor national scientific user facility advancing nuclear technology

    International Nuclear Information System (INIS)

    Allen, T.R.; Thelen, M.C.; Meyer, M.K.; Marshall, F.M.; Foster, J.; Benson, J.B.

    2009-01-01

    To help ensure the long-term viability of nuclear energy through a robust and sustained research and development effort, the U.S. Department of Energy (DOE) designated the Advanced Test Reactor and associated post-irradiation examination facilities a National Scientific User Facility (ATR NSUF), allowing broader access to nuclear energy researchers. The mission of the ATR NSUF is to provide access to world-class nuclear research facilities, thereby facilitating the advancement of nuclear science and technology. The ATR NSUF seeks to create an engaged academic and industrial user community that routinely conducts reactor-based research. Cost free access to the ATR and PIE facilities is granted based on technical merit to U.S. university-led experiment teams conducting non-proprietary research. Proposals are selected via independent technical peer review and relevance to DOE mission. Extensive publication of research results is expected as a condition for access. During FY 2008, the first full year of ATR NSUF operation, five university-led experiments were awarded access to the ATR and associated post-irradiation examination facilities. The ATR NSUF has awarded four new experiments in early FY 2009, and anticipates awarding additional experiments in the fall of 2009 as the results of the second 2009 proposal call. As the ATR NSUF program mature over the next two years, the capability to perform irradiation research of increasing complexity will become available. These capabilities include instrumented irradiation experiments and post-irradiation examinations on materials previously irradiated in U.S. reactor material test programs. The ATR critical facility will also be made available to researchers. An important component of the ATR NSUF an education program focused on the reactor-based tools available for resolving nuclear science and technology issues. The ATR NSUF provides education programs including a summer short course, internships, faculty-student team

  10. Condition Parameter Modeling for Anomaly Detection in Wind Turbines

    Directory of Open Access Journals (Sweden)

    Yonglong Yan

    2014-05-01

    Full Text Available Data collected from the supervisory control and data acquisition (SCADA system, used widely in wind farms to obtain operational and condition information about wind turbines (WTs, is of important significance for anomaly detection in wind turbines. The paper presents a novel model for wind turbine anomaly detection mainly based on SCADA data and a back-propagation neural network (BPNN for automatic selection of the condition parameters. The SCADA data sets are determined through analysis of the cumulative probability distribution of wind speed and the relationship between output power and wind speed. The automatic BPNN-based parameter selection is for reduction of redundant parameters for anomaly detection in wind turbines. Through investigation of cases of WT faults, the validity of the automatic parameter selection-based model for WT anomaly detection is verified.

  11. Detailed leak detection test plan and schedule for the Oak Ridge National Laboratory LLLW active pipelines

    International Nuclear Information System (INIS)

    Douglas, D.G.; Starr, J.W.; Juliano, T.M.; Maresca, J.W. Jr.

    1993-09-01

    This document provides a detailed leak detection test plan and schedule for leak testing many of the pipelines that comprise the active portion of the liquid low-level waste (LLLW) system at the Oak Ridge National Laboratory (ORNL). This plan was prepared in response to the requirements of the Federal Facility Agreement (FFA) between the US Department of Energy (DOE) and two other agencies, the US Environmental Protection Agency (EPA) and the Tennessee Department of Environment and Conservation (TDEC). The LLLW system is an interconnected complex of tanks and pipelines. The FFA distinguishes four categories of tank and pipeline systems within this complex: new systems (Category A), doubly contained systems (Category B), singly contained systems (Category C), and inactive systems (Category D). The FFA specifically requires leak testing of the Category C systems. This plan and schedule addresses leak testing of the Category C pipelines and those doubly contained pipelines that do not fully meet the requirements for secondary containment as listed in the FFA

  12. What Makes Nations Intelligent?

    Science.gov (United States)

    Hunt, Earl

    2012-05-01

    Modern society is driven by the use of cognitive artifacts: physical instruments or styles of reasoning that amplify our ability to think. The artifacts range from writing systems to computers. In everyday life, a person demonstrates intelligence by showing skill in using these artifacts. Intelligence tests and their surrogates force examinees to exhibit some of these skills but not others. This is why test scores correlate substantially but not perfectly with a variety of measures of socioeconomic success. The same thing is true at the international level. Nations can be evaluated by the extent to which their citizens score well on cognitive tests, including both avowed intelligence tests and a variety of tests of academic achievement. The resulting scores are substantially correlated with various indices of national wealth, health, environmental quality, and schooling and with a vaguer variable, social commitment to innovation. These environmental variables are suggested as causes of the differences in general cognitive skills between national populations. It is conceivable that differences in gene pools also contribute to international and, within nations, group differences in cognitive skills, but at present it is impossible to evaluate the extent of genetic influences. © The Author(s) 2012.

  13. GEO light imaging national testbed (GLINT) heliostat design and testing status

    Science.gov (United States)

    Thornton, Marcia A.; Oldenettel, Jerry R.; Hult, Dane W.; Koski, Katrina; Depue, Tracy; Cuellar, Edward L.; Balfour, Jim; Roof, Morey; Yarger, Fred W.; Newlin, Greg; Ramzel, Lee; Buchanan, Peter; Mariam, Fesseha G.; Scotese, Lee

    2002-01-01

    The GEO Light Imaging National Testbed (GLINT) will use three laser beams producing simultaneous interference fringes to illuminate satellites in geosynchronous earth orbit (GEO). The reflected returns will be recorded using a large 4,000 m2 'light bucket' receiver. This imaging methodology is termed Fourier Telescopy. A major component of the 'light bucket' will be an array of 40 - 80 heliostats. Each heliostat will have a mirrored surface area of 100 m2 mounted on a rigid truss structure which is supported by an A-frame. The truss structure attaches to the torque tube elevation drive and the A-frame structure rests on an azimuth ring that could provide nearly full coverage of the sky. The heliostat is designed to operate in 15 mph winds with jitter of less than 500 microradians peak-to- peak. One objective of the design was to minimize receiver cost to the maximum extent possible while maintaining GLINT system performance specifications. The mechanical structure weights approximately seven tons and is a simple fabricated steel framework. A prototype heliostat has been assembled at Stallion Range Center, White Sands Missile Range, New Mexico and is being tested under a variety of weather and operational conditions. The preliminary results of that testing will be presented as well as some finite element model analyses that were performed to predict the performance of the structure.

  14. Sandia National Laboratories, Tonopah Test Range Fire Control Bunker (Building 09-51): Photographs and Written Historical and Descriptive Data

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, Rebecca A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Corporate Archives and History Program

    2017-08-01

    The Fire Control Bunker (Building 09-51) is a contributing element to the Sandia National Laboratories (SNL) Tonopah Test Range (TTR) Historic District. The SNL TTR Historic District played a significant role in U.S. Cold War history in the areas of stockpile surveillance and non-nuclear field testing of nuclear weapons design. The district covers approximately 179,200 acres and illustrates Cold War development testing of nuclear weapons components and systems. This report includes historical information, architectural information, sources of information, project information, maps, blueprints, and photographs.

  15. Los Alamos and Lawrence Livermore National Laboratories Code-to-Code Comparison of Inter Lab Test Problem 1 for Asteroid Impact Hazard Mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Robert P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Miller, Paul [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Howley, Kirsten [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ferguson, Jim Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gisler, Galen Ross [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Plesko, Catherine Suzanne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Managan, Rob [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Owen, Mike [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wasem, Joseph [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bruck-Syal, Megan [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-01-15

    The NNSA Laboratories have entered into an interagency collaboration with the National Aeronautics and Space Administration (NASA) to explore strategies for prevention of Earth impacts by asteroids. Assessment of such strategies relies upon use of sophisticated multi-physics simulation codes. This document describes the task of verifying and cross-validating, between Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL), modeling capabilities and methods to be employed as part of the NNSA-NASA collaboration. The approach has been to develop a set of test problems and then to compare and contrast results obtained by use of a suite of codes, including MCNP, RAGE, Mercury, Ares, and Spheral. This document provides a short description of the codes, an overview of the idealized test problems, and discussion of the results for deflection by kinetic impactors and stand-off nuclear explosions.

  16. File Carving and Malware Identification Algorithms Applied to Firmware Reverse Engineering

    Science.gov (United States)

    2013-03-21

    Internet, and use of common network protocols, enable nuisance hacker attacks. Search engines like SHODAN make searching for Internet-facing SCADA networks... pipeline leak in Bellingham, Washington, to pipeline damage and degraded SCADA software performance [1]. The leak and a subsequent explosion resulted in... FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED The views expressed in this thesis are those of the author and do not reflect the official policy or

  17. Anomaly Detection in Liquid Pipelines Using Modeling, Co-Simulation and Dynamical Estimation

    OpenAIRE

    Alajlouni , Saed; Rao , Vittal

    2013-01-01

    Part 3: Infrastructure Security; International audience; Historically, supervisory control and data acquisition (SCADA) systems have relied on obscurity to safeguard against attacks. Indeed, external attackers lacked knowledge about proprietary system designs and software to access systems and execute attacks. The trend to interconnect to the Internet and incorporate standardized protocols, however, has resulted in an increase in the attack surface – attackers can now target SCADA systems and...

  18. Liquid Rocket Engine Testing

    Science.gov (United States)

    Rahman, Shamim

    2005-01-01

    Comprehensive Liquid Rocket Engine testing is essential to risk reduction for Space Flight. Test capability represents significant national investments in expertise and infrastructure. Historical experience underpins current test capabilities. Test facilities continually seek proactive alignment with national space development goals and objectives including government and commercial sectors.

  19. Report of test and research results on atomic energy obtained in national institutes in fiscal 1992

    International Nuclear Information System (INIS)

    1994-01-01

    The tests and researches on the development and utilization of atomic energy in national laboratories were begun in 1956, and have accomplished the great role for the advance of the development and utilization of atomic energy in Japan by having produced many valuable results so far. Atomic energy has been utilized not only in the field of nuclear power but also in diverse fields, and in national laboratories, the research for expanding the development and utilization of atomic energy in medicine, agriculture, forestry, fishery, radioactivation analysis and others in addition the basic research on nuclear fusion have been advanced. Further expecting the pervasive effect to general science and technology, the development of integrated research are promoted from the viewpoint of new technical innovation and creative technology. The safety research of nuclear facilities have been carried out to keep them high level on the basis of the yearly program enacted by Nuclear Safety Commission. This is the report No. 33, in which the results of the test and research in the fields of nuclear fusion safety research, food irradiation, cancer countermeasures, agriculture, forestry, fishery, medicine, mining and manufacture, power utilization, construction, radioactivation analysis carried on in fiscal 1992 are summarized. (J.P.N.)

  20. Collaborative National Program for the Development and Performance Testing of Distributed Power Technologies with Emphasis on Combined Heat and Power Applications

    Energy Technology Data Exchange (ETDEWEB)

    Soinski, Arthur; Hanson, Mark

    2006-06-28

    A current barrier to public acceptance of distributed generation (DG) and combined heat and power (CHP) technologies is the lack of credible and uniform information regarding system performance. Under a cooperative agreement, the Association of State Energy Research and Technology Transfer Institutions (ASERTTI) and the U.S. Department of Energy have developed four performance testing protocols to provide a uniform basis for comparison of systems. The protocols are for laboratory testing, field testing, long-term monitoring and case studies. They have been reviewed by a Stakeholder Advisory Committee made up of industry, public interest, end-user, and research community representatives. The types of systems covered include small turbines, reciprocating engines (including Stirling Cycle), and microturbines. The protocols are available for public use and the resulting data is publicly available in an online national database and two linked databases with further data from New York State. The protocols are interim pending comments and other feedback from users. Final protocols will be available in 2007. The interim protocols and the national database of operating systems can be accessed at www.dgdata.org. The project has entered Phase 2 in which protocols for fuel cell applications will be developed and the national and New York databases will continue to be maintained and populated.

  1. ETHERNET соединение между контролером SIMATIC S7-200 и SCADA системной WinCC с использованием технологии ОРС

    Directory of Open Access Journals (Sweden)

    В. М. Левинский

    2014-12-01

    Full Text Available Показан пример практической реализации взаимосвязи контроллера SIMATIC S7-200 и SCADA системы WinCC по сети ETHERNET с использованием NET OPC.

  2. A Fusion of Multiagent Functionalities for Effective Intrusion Detection System

    Directory of Open Access Journals (Sweden)

    Dhanalakshmi Krishnan Sadhasivan

    2017-01-01

    Full Text Available Provision of high security is one of the active research areas in the network applications. The failure in the centralized system based on the attacks provides less protection. Besides, the lack of update of new attacks arrival leads to the minimum accuracy of detection. The major focus of this paper is to improve the detection performance through the adaptive update of attacking information to the database. We propose an Adaptive Rule-Based Multiagent Intrusion Detection System (ARMA-IDS to detect the anomalies in the real-time datasets such as KDD and SCADA. Besides, the feedback loop provides the necessary update of attacks in the database that leads to the improvement in the detection accuracy. The combination of the rules and responsibilities for multiagents effectively detects the anomaly behavior, misuse of response, or relay reports of gas/water pipeline data in KDD and SCADA, respectively. The comparative analysis of the proposed ARMA-IDS with the various existing path mining methods, namely, random forest, JRip, a combination of AdaBoost/JRip, and common path mining on the SCADA dataset conveys that the effectiveness of the proposed ARMA-IDS in the real-time fault monitoring. Moreover, the proposed ARMA-IDS offers the higher detection rate in the SCADA and KDD cup 1999 datasets.

  3. National Science Bowl | NREL

    Science.gov (United States)

    Science Bowl National Science Bowl The Department of Energy's Office of Science sponsors the National Science Bowl competition. This fun, fast-paced academic tournament tests the brainpower of middle and high school student teams on science and math topics. The National Science Bowl provides an

  4. Relationships between the National Adult Reading Test and memory.

    Science.gov (United States)

    Frick, Andreas; Wahlin, Tarja-Brita Robins; Pachana, Nancy A; Byrne, Gerard J

    2011-05-01

    The aims of this study were to investigate the relationships between performance on the National Adult Reading Test (NART) and retrospective, concurrent, and prospective memory functioning, as well as between the NART and change in memory functioning over time. NART administered in 2005 was used as a predictor for memory functioning in 2001, 2005, and 2008, and change in memory functioning from 2001 to 2008. Outcome measures were Logical Memory II, Letter-Number Sequencing, and Spatial Span from the Wechsler Memory Scale. Participants were 319 healthy women aged 40-79 years at baseline (2001). Significant correlations were found between the number of errors on the NART and memory measures in 2001, 2005, and 2008; Logical Memory II (r = -.41, -.38, -.39, respectively), Letter-Number Sequencing (r = -.38, -.35, -.36, respectively) and Spatial Span (r = -.23, -.22, -.19, respectively; all p values memory, after controlling for age, level of education and socioeconomic status. NART also significantly added to predictions of change in Logical Memory II and Letter-Number Sequencing over a 7-year period. The results indicate that the NART is correlated with episodic and working memory, and that the NART added to predictions of change in verbal episodic and working memory. Although the relationships are only moderate at best, the NART may be used in conjunction with demographic information and clinical reasoning to estimate premorbid memory functioning.

  5. Brookhaven National Laboratory's Accelerator Test Facility: research highlights and plans

    Science.gov (United States)

    Pogorelsky, I. V.; Ben-Zvi, I.

    2014-08-01

    The Accelerator Test Facility (ATF) at Brookhaven National Laboratory has served as a user facility for accelerator science for over a quarter of a century. In fulfilling this mission, the ATF offers the unique combination of a high-brightness 80 MeV electron beam that is synchronized to a 1 TW picosecond CO2 laser. We unveil herein our plan to considerably expand the ATF's floor space with an upgrade of the electron beam's energy to 300 MeV and the CO2 laser's peak power to 100 TW. This upgrade will propel the ATF even further to the forefront of research on advanced accelerators and radiation sources, supporting the most innovative ideas in this field. We discuss emerging opportunities for scientific breakthroughs, including the following: plasma wakefield acceleration studies in research directions already active at the ATF; laser wakefield acceleration (LWFA), where the longer laser wavelengths are expected to engender a proportional increase in the beam's charge while our linac will assure, for the first time, the opportunity to undertake detailed studies of seeding and staging of the LWFA; proton acceleration to the 100-200 MeV level, which is essential for medical applications; and others.

  6. 75 FR 5303 - Tests Determined To Be Suitable for Use in the National Reporting System for Adult Education (NRS)

    Science.gov (United States)

    2010-02-02

    ... DEPARTMENT OF EDUCATION Tests Determined To Be Suitable for Use in the National Reporting System for Adult Education (NRS) AGENCY: Office of Vocational and Adult Education, Department of Education.... FOR FURTHER INFORMATION CONTACT: Mike Dean, U.S. Department of Education, 400 Maryland Avenue, SW...

  7. Hydrogen Fuel Cell Vehicle Fuel Economy Testing at the U.S. EPA National Vehicle and Fuel Emissions Laboratory (SAE Paper 2004-01-2900)

    Science.gov (United States)

    The introduction of hydrogen fuel cell vehicles and their new technology has created the need for development of new fuel economy test procedures and safety procedures during testing. The United States Environmental Protection Agency-National Vehicle Fuels and Emissions Laborato...

  8. National trends in the usage and success of sacral nerve test stimulation.

    Science.gov (United States)

    Cameron, Anne P; Anger, Jennifer T; Madison, Rodger; Saigal, Christopher S; Clemens, J Quentin

    2011-03-01

    Little is known about outcomes of sacral neuromodulation in the general community, with published reports to date limited to case series or randomized, controlled trials. The goal of this analysis was to identify the national sacral neuromodulation test phase success rate and patient factors that contribute to success. Medical claims data were obtained from a 5% sample of Medicare beneficiaries (1997 to 2007) and from employees of 25 large (Fortune 500) companies (Ingenix®, 2002 to 2007). Using billing codes for the sacral neuromodulation procedure, success was defined as progressing from test phase (percutaneous or staged) to battery implantation. The rate of success was compared based on age, race, gender and diagnosis. In the Medicare sample 358 patients received percutaneous test stimulation and 1,132 underwent 2-stage lead placement, of whom 45.8% and 35.4%, respectively, underwent subsequent battery implantation. In the privately insured sample there were 266 percutaneous procedures and 794, 2-stage procedures. Percutaneous procedures were followed by battery placement in 24.1% of cases, whereas 50.9% of staged procedures resulted in battery implantation. Gender was the only consistent predictor of success, with female patients demonstrating higher success rates in each data set. The sacral neuromodulation success rates in these data sets are inferior to those published in case series and small randomized, controlled trials. Women had significantly better results than men and privately insured individuals had better results than those with Medicare, indicating a potential age effect. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. Programmable Logic Controller Modification Attacks for use in Detection Analysis

    Science.gov (United States)

    2014-03-27

    and J. Lowe, “The Myths and Facts Behind Cyber Security Risks for Industrial Control Systems ,” in Proceedings of the VDE Kongress, vol. 116, 2004. [13...Feb 2014 Date 20 Feb 2014 Date 20 Feb 2014 Date AFIT-ENG-14-M-66 Abstract Unprotected Supervisory Control and Data Acquisition (SCADA) systems offer...control and monitor physical industrial processes. Although attacks targeting SCADA systems have increased, there has been little work exploring the

  10. Separate individual control systems come together at EP2

    International Nuclear Information System (INIS)

    Podmore, A.

    1991-01-01

    At BNFL's EP2 radioactive waste encapsulation plant in the UK, eight area supervisory control and data acquisition systems (SCADAs) and one central SCADA are being installed to provide computer-controlled processing of waste drums. The individual systems are all autonomous, minimizing the effect they have on other areas of the process. At the same time, they are part of an integrated system which provides effective communication between the various areas. (author)

  11. Terra Defender Cyber-Physical Wargame

    Science.gov (United States)

    2017-04-01

    time. However, the WHITE team did not offer game-dollar rewards for these actions and this probably caused low motivation for note-taking. In general...helped to achieve a better understanding of how Army supervisory control and data acquisition (SCADA) system and device security can be modeled and...managed. Terra game players obtained first-hand experience in attacking and defending a live (“operational”) SCADA system that was located in a testbed

  12. Standardization of detector control systems

    International Nuclear Information System (INIS)

    Fukunaga, Chikara

    2000-01-01

    Current and future detectors for high-energy and/or nuclear physics experiments require highly intelligent detector control systems. In order to reduce resources, the construction of a standardized template for the control systems based on the commercially available superviser control and data acquisition (SCADA) system has been proposed. The possibility of constructing this template is discussed and several key issues for evaluation of SCADA as the basis for such a template are presented. (author)

  13. Resumption of surrogate testing in the Engineering Demonstration System at the Lawrence Livermore National Laboratory: Environmental assessment

    International Nuclear Information System (INIS)

    1990-04-01

    The Engineering Demonstration System (EDS) is an existing equipment system within the Plutonium Facility at the Lawrence Livermore National Laboratory (LLNL) designed to test the Atomic Vapor Laser Isotope Separation (AVLIS) process for application to the Special Isotope Separation (SIS) program. The proposed action is to resume testing with members of the family of rare-earth metals in the EDS. The purpose of these tests is to train operators, verify operations procedures and obtain information on the engineering design, operational reliability, and separative performance capability of the integrated system hardware. The information to be provided by the EDS tests with the rare-earth metals is needed for engineering and operability evaluation of the prototype AVLIS separator hardware in an integrated system configuration. These evaluations are necessary to demonstrate the technology to the maximum extent possible, short of actual validation with plutonium. The EDS tests to be performed would use single and multiple separator units. Testing would be intermittent in nature, typically consisting of one to two tests per month, with durations ranging from approximately 10 to 200 h. 19 refs., 4 figs., 5 tabs

  14. Impacts Analyses Supporting the National Environmental Policy Act Environmental Assessment for the Resumption of Transient Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Annette L. Schafer; Lloyd C. Brown; David C. Carathers; Boyd D. Christensen; James J. Dahl; Mark L. Miller; Cathy Ottinger Farnum; Steven Peterson; A. Jeffrey Sondrup; Peter V. Subaiya; Daniel M. Wachs; Ruth F. Weiner

    2013-11-01

    Environmental and health impacts are presented for activities associated with transient testing of nuclear fuel and material using two candidate test reactors. Transient testing involves irradiation of nuclear fuel or materials for short time-periods under high neutron flux rates. The transient testing process includes transportation of nuclear fuel or materials inside a robust shipping cask to a hot cell, removal from the shipping cask, pre-irradiation examination of the nuclear materials, assembly of an experiment assembly, transportation of the experiment assembly to the test reactor, irradiation in the test reactor, transport back to the hot cell, and post-irradiation examination of the nuclear fuel or material. The potential for environmental or health consequences during the transportation, examination, and irradiation actions are assessed for normal operations, off-normal (accident) scenarios, and transportation. Impacts to the environment (air, soil, and groundwater), are assessed during each phase of the transient testing process. This report documents the evaluation of potential consequences to the general public. This document supports the Environmental Assessment (EA) required by the U.S. National Environmental Policy Act (NEPA) (42 USC Subsection 4321 et seq.).

  15. A retrospective evaluation of proficiency testing, and rapid HIV test ...

    African Journals Online (AJOL)

    Background: Proficiency testing (PT) has been implemented as a form of External Quality Assurance (EQA) by the National HIV Reference Laboratory in Kenya since 2007 in order to monitor and improve on the quality of HIV testing and counselling HTC services. Objective: To compare concordance between National HIV ...

  16. Physical Attributes and NFL Combine Performance Tests Between Italian National League and American Football Players: A Comparative Study.

    Science.gov (United States)

    Vitale, Jacopo A; Caumo, Andrea; Roveda, Eliana; Montaruli, Angela; La Torre, Antonio; Battaglini, Claudio L; Carandente, Franca

    2016-10-01

    Vitale, JA, Caumo, A, Roveda, E, Montaruli, A, La Torre, A, Battaglini, CL, and Carandente, F. Physical attributes and NFL Combine performance tests between Italian National League and American football players: a comparative study. J Strength Cond Res 30(10): 2802-2808, 2016-The purpose of this study was to examine anthropometric measurements and the results of a battery of performance tests administered during the National Football League (NFL) Combine between American football players who were declared eligible to participate in the NFL Combine and football players of a top Italian team (Rhinos Milan). Participants (N = 50) were categorized by position into 1 of 3 groups based on playing position: skill players (SP) included wide receivers, cornerbacks, free safeties, strong safeties, and running backs; big skill players (BSP) consisted of fullbacks, linebackers, tight ends, and defensive ends; lineman (LM) included centers, offensive guards, offensive tackles, and defensive tackles. A 1-way analysis of variance followed by the Tukey-Kramer post hoc test was used for comparisons between Italian players by playing position. Ninety-five percent CIs were used for comparisons between American and Italian football for the NFL Combine performance tests. Significant differences for all the variables between the 3 playing categories were observed among the Italian players; LM had higher anthropometric and body composition values than SP (p football players presented significantly higher anthropometric values and test performance scores when compared with Italian players. Administrators of professional football teams in Italy need to improve the player's physical attributes, so the gap that currently exists between American and Italian players can be reduced, which could significantly improve the quality of American football in Italy.

  17. A test system and supervisory control and data acquisition application with programmable logic controller for thermoelectric generators

    International Nuclear Information System (INIS)

    Ahiska, Rasit; Mamur, Hayati

    2012-01-01

    Highlights: ► A new TEG test measurement system with the PLC has been carried out. ► A new SCADA program has been written and tested for the test measurement system. ► An operator panel has been used for monitoring to the instant TEG data. ► All of the measurement data of TEG have been aggregated in the system. - Abstract: In this study, a new test measurement system and supervisory control and data acquisition application with programmable logic controller has been carried out to be enable the collection of the data of thermoelectric generator for the usage of thermoelectric modules as thermoelectric generator. During the production of the electric energy from the thermoelectric generator, the temperatures of the surfaces of the thermoelectric generator, current–voltage values obtained from output of the thermoelectric generator, hot and cold flows have been measured by the newly established system instantly. All these data have been monitored continuously from the computer and recorded by a supervisory control and data acquisition program. At the same time, in environments where there was no computer, an operator panel with the ability to communicate with the programmable logic controller has been added for the monitoring of the instant thermoelectric generator data. All of the measurement data of the thermoelectric generator have been aggregated in the new test measurement and supervisory control and data acquisition system. The setup test measurement system has been implemented on the thermoelectric generator system with about 10 W. Thermoelectric generators, Altec-GM-1 brand-coded have been examined by the new proposed test measurement system and the values of maximum power and thermoelectric generator efficiency were calculated by the programmable logic controller. When the obtained results were compared with the datasheets, the relative error for the maximum power was around 4% and the value for efficiency was below 3%.

  18. Usability Testing of a National Substance Use Screening Tool Embedded in Electronic Health Records.

    Science.gov (United States)

    Press, Anne; DeStio, Catherine; McCullagh, Lauren; Kapoor, Sandeep; Morley, Jeanne; Conigliaro, Joseph

    2016-07-08

    Screening, brief intervention, and referral to treatment (SBIRT) is currently being implemented into health systems nationally via paper and electronic methods. The purpose of this study was to evaluate the integration of an electronic SBIRT tool into an existing paper-based SBIRT clinical workflow in a patient-centered medical home. Usability testing was conducted in an academic ambulatory clinic. Two rounds of usability testing were done with medical office assistants (MOAs) using a paper and electronic version of the SBIRT tool, with two and four participants, respectively. Qualitative and quantitative data was analyzed to determine the impact of both tools on clinical workflow. A second round of usability testing was done with the revised electronic version and compared with the first version. Personal workflow barriers cited in the first round of testing were that the electronic health record (EHR) tool was disruptive to patient's visits. In Round 2 of testing, MOAs reported favoring the electronic version due to improved layout and the inclusion of an alert system embedded in the EHR. For example, using the system usability scale (SUS), MOAs reported a grade "1" for the statement, "I would like to use this system frequently" during the first round of testing but a "5" during the second round of analysis. The importance of testing usability of various mediums of tools used in health care screening is highlighted by the findings of this study. In the first round of testing, the electronic tool was reported as less user friendly, being difficult to navigate, and time consuming. Many issues faced in the first generation of the tool were improved in the second generation after usability was evaluated. This study demonstrates how usability testing of an electronic SBRIT tool can help to identify challenges that can impact clinical workflow. However, a limitation of this study was the small sample size of MOAs that participated. The results may have been biased to

  19. Sandia National Laboratories, Tonopah Test Range Assembly Building 9B (Building 09-54): Photographs and Written Historical and Descriptive Data

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, Rebecca A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Corporate Archives and History Program

    2017-08-01

    Assembly Building 9B (Building 09-54) is a contributing element to the Sandia National Laboratories (SNL) Tonopah Test Range (TTR) Historic District. The SNL TTR Historic District played a significant role in U.S. Cold War history in the areas of stockpile surveillance and non-nuclear field testing of nuclear weapons designs. The district covers approximately 179,200 acres and illustrates Cold War development testing of nuclear weapons components and systems. This report includes historical information, architectural information, sources of information, project information, maps, blueprints, and photographs.

  20. Chemical Reactivity Testing for the National Spent Nuclear Fuel Program. Quality Assurance Project Plan

    International Nuclear Information System (INIS)

    Newsom, H.C.

    1999-01-01

    This quality assurance project plan (QAPjP) summarizes requirements used by Lockheed Martin Energy Systems, Incorporated (LMES) Development Division at Y-12 for conducting chemical reactivity testing of Department of Energy (DOE) owned spent nuclear fuel, sponsored by the National Spent Nuclear Fuel Program (NSNFP). The requirements are based on the NSNFP Statement of Work PRO-007 (Statement of Work for Laboratory Determination of Uranium Hydride Oxidation Reaction Kinetics.) This QAPjP will utilize the quality assurance program at Y-12, QA-101PD, revision 1, and existing implementing procedures for the most part in meeting the NSNFP Statement of Work PRO-007 requirements, exceptions will be noted

  1. A distribution management system

    Energy Technology Data Exchange (ETDEWEB)

    Jaerventausta, P; Verho, P; Kaerenlampi, M; Pitkaenen, M [Tampere Univ. of Technology (Finland); Partanen, J [Lappeenranta Univ. of Technology (Finland)

    1998-08-01

    The development of new distribution automation applications is considerably wide nowadays. One of the most interesting areas is the development of a distribution management system (DMS) as an expansion to the traditional SCADA system. At the power transmission level such a system is called an energy management system (EMS). The idea of these expansions is to provide supporting tools for control center operators in system analysis and operation planning. Nowadays the SCADA is the main computer system (and often the only) in the control center. However, the information displayed by the SCADA is often inadequate, and several tasks cannot be solved by a conventional SCADA system. A need for new computer applications in control center arises from the insufficiency of the SCADA and some other trends. The latter means that the overall importance of the distribution networks is increasing. The slowing down of load-growth has often made network reinforcements unprofitable. Thus the existing network must be operated more efficiently. At the same time larger distribution areas are for economical reasons being monitored at one control center and the size of the operation staff is decreasing. The quality of supply requirements are also becoming stricter. The needed data for new applications is mainly available in some existing systems. Thus the computer systems of utilities must be integrated. The main data source for the new applications in the control center are the AM/FM/GIS (i.e. the network database system), the SCADA, and the customer information system (CIS). The new functions can be embedded in some existing computer system. This means a strong dependency on the vendor of the existing system. An alternative strategy is to develop an independent system which is integrated with other computer systems using well-defined interfaces. The latter approach makes it possible to use the new applications in various computer environments, having only a weak dependency on the

  2. Provider-initiated HIV testing & counselling in incident tuberculosis cases under National TB Programme conditions at a tertiary care teaching hospital in Tirupati, south India

    Directory of Open Access Journals (Sweden)

    Alladi Mohan

    2017-01-01

    >Interpretation & conclusions: The findings of this study showed that a higher proportion of TB patients underwent HIV testing (75% compared to the national figure of 63 per cent in 2013-2014. HIV seropositivity (4.6% in TB patients who underwent HIV testing was similar to the five per cent figure observed at national level during 2013-2014. The HIV status of 25 per cent of patients with incident TB still remained unknown, suggesting a need for better integration and co-ordination for effective management of HIV-TB co-infection.

  3. Testing capabilities of Los Alamos National Laboratory for irradiated materials

    International Nuclear Information System (INIS)

    Maloy, S.A.; James, M.R.; Sommer, W.F.

    1999-01-01

    Spallation neutron sources expose materials to high energy (>100 MeV) proton and neutron spectra. Although numerous studies have investigated the effects of radiation damage in a lower energy neutron flux from fission or fusion reactors on the mechanical properties of materials, very little work has been performed on the effects that exposure to a spallation neutron spectrum has on the mechanical properties of materials. These effects can be significantly different than those observed in a fission or fusion reactor spectrum because exposure to high energy protons and neutrons produces more He and H along with the atomic displacement damage. Los Alamos National Laboratory has unique facilities to study the effects of spallation radiation damage on the mechanical properties of materials. The Los Alamos Neutron Science Center (LANSCE) has a pulsed linear accelerator which operates at 800 MeV and 1 mA. The Los Alamos Spallation Radiation Effect Facility (LASREF) located at the end of this accelerator is designed to allow the irradiation of components in a proton beam while water cooling these components and measuring their temperature. After irradiation, specimens can be investigated at hot cells located at the Chemical Metallurgy Research Building. Wing 9 of this facility contains 16 hot cells set up in two groups of eight, each having a corridor in the center to allow easy transfer of radioactive shipments into and out of the hot cells. These corridors have been used to prepare specimens for shipment to collaborating laboratories such as PNNL, ORNL, BNL, and the Paul Scherrer Institute to perform specialized testing at their hot cells. The LANL hot cells contain capabilities for opening radioactive components and testing their mechanical properties as well as preparing specimens from irradiated components

  4. New Sensors for In-Pile Temperature Detection at the Advanced Test Reactor National Scientific User Facility

    International Nuclear Information System (INIS)

    Rempe, J.L.; Knudson, D.L.; Daw, J.E.; Condie, K.G.; Wilkins, S. Curtis

    2009-01-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. As a user facility, the ATR is supporting new users from universities, laboratories, and industry, as they conduct basic and applied nuclear research and development to advance the nation's energy security needs. A key component of the ATR NSUF effort is to develop and evaluate new in-pile instrumentation techniques that are capable of providing measurements of key parameters during irradiation. This paper describes the strategy for determining what instrumentation is needed and the program for developing new or enhanced sensors that can address these needs. Accomplishments from this program are illustrated by describing new sensors now available and under development for in-pile detection of temperature at various irradiation locations in the ATR.

  5. Cultural Resource Assessment of the Test Area North Demolition Landfill at the Idaho National Engineering and Environmental Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Brenda R. Pace

    2003-07-01

    The proposed new demolition landfill at Test Area North on the Idaho National Engineering and Environmental Laboratory (INEEL) will support ongoing demolition and decontamination within the facilities on the north end of the INEEL. In June of 2003, the INEEL Cultural Resource Management Office conducted archival searches, field surveys, and coordination with the Shoshone-Bannock Tribes to identify all cultural resources that might be adversely affected by the project and to provide recommendations to protect those listed or eligible for listing on the National Register of Historic Places. These investigations showed that landfill construction and operation would affect two significant cultural resources. This report outlines protective measures to ensure that these effects are not adverse.

  6. Cultural Resource Assessment of the Test Area North Demolition Landfill at the Idaho National Engineering and Environmental Laboratory

    International Nuclear Information System (INIS)

    Brenda R. Pace

    2003-01-01

    The proposed new demolition landfill at Test Area North on the Idaho National Engineering and Environmental Laboratory (INEEL) will support ongoing demolition and decontamination within the facilities on the north end of the INEEL. In June of 2003, the INEEL Cultural Resource Management Office conducted archival searches, field surveys, and coordination with the Shoshone-Bannock Tribes to identify all cultural resources that might be adversely affected by the project and to provide recommendations to protect those listed or eligible for listing on the National Register of Historic Places. These investigations showed that landfill construction and operation would affect two significant cultural resources. This report outlines protective measures to ensure that these effects are not adverse

  7. Climatic Warmth and National Wealth: Some Culture-Level Determinants of National Character Stereotypes.

    Science.gov (United States)

    McCrae, Robert R; Terracciano, Antonio; Realo, Anu; Allik, Jüri

    2007-12-01

    National character stereotypes are widely shared, but do not reflect assessed levels of personality traits. In this article we present data illustrating the divergence of stereotypes and assessed personality traits in north and south Italy, test hypotheses about the associations of temperature and national wealth with national character stereotypes in 49 cultures, and explore possible links to national values and beliefs. Results suggest that warmth and wealth are common determinants of national stereotypes, but that there are also idiosyncratic influences on the perceptions of individual nations.

  8. The electromagnetic integrated demonstration at the Idaho National Engineering Laboratory cold test pit

    International Nuclear Information System (INIS)

    Pellerin, L.; Alumbaugh, D.L.; Pfeifer, M.C.

    1997-01-01

    The electromagnetic integrated demonstration (EMID) is a baseline study in electromagnetic (EM) exploration of the shallow subsurface (< 10 m). Eleven distinct EM systems, covering the geophysical spectrum, acquired data on a grid over the Idaho National Engineering Laboratory (INEL) Cold Test Pit (CTP). The systems are investigated and evaluated for the purpose of identifying and reviewing existing geophysical characterization instrumentation (commercial and experimental), integrating those technologies with multi-dimensional interpretational algorithms, and identifying gaps in shallow subsurface EM imaging technology. The EMID data, are valuable for testing and evaluating new interpretational software, and developing techniques for integrating multiple datasets. The experimental field techniques shows how the acquisition of data in a variety of array configurations can considerably enhance interpretation. All data are available on the world wide web. Educators and students are encouraged to use the data for both classroom and graduate studies. The purpose of this paper is to explain why, where, how and what kind of data were collected. It is left to the reader to assess the value of a given system for their particular application. Information about the EMID is organized into two general categories: survey description and system evaluation

  9. Radiation Testing at Sandia National Laboratories: Sandia – JPL Collaboration for Europa Lander

    Energy Technology Data Exchange (ETDEWEB)

    Hattar, Khalid Mikhiel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Ion Beam Lab.; Olszewska-Wasiolek, Maryla Aleksandra [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Gamma Irradiation Facility

    2017-01-01

    Sandia National Laboratories (SNL) is assisting Jet Propulsion Laboratory in undertaking feasibility studies and performance assessments for the Planetary Protection aspect of the Europa Lander mission. The specific areas of interest for this project are described by task number. This white paper presents the evaluation results for Task 2, Radiation Testing, which was stated as follows: Survey SNL facilities and capabilities for simulating the Europan radiation environment and assess suitability for: A. Testing batteries, electronics, and other component and subsystems B. Exposing biological organisms to assess their survivability metrics. The radiation environment the Europa Lander will encounter on route and in orbit upon arrival at its destination consists primarily of charged particles, energetic protons and electrons with the energies up to 1 GeV. The charged particle environments can be simulated using the accelerators at the Ion Beam Laboratory. The Gamma Irradiation Facility and its annex, the Low Dose Rate Irradiation Facility, offer irradiations using Co-60 gamma sources (1.17 and 1.33 MeV), as well as Cs-137 gamma (0.661 MeV) AmBe neutron (0-10 MeV) sources.

  10. Status of Cryogenic System for Spallation Neutron Source's Superconducting Radiofrequency Test Facility at Oak Ridge National Lab

    International Nuclear Information System (INIS)

    Xu, Ting; Casagrande, Fabio; Ganni, Venkatarao; Knudsen, Peter N.; Strong, William Herb

    2011-01-01

    Spallation Neutron Source (SNS) at Oak Ridge National Lab (ORNL) is building an independent cryogenic system for its Superconducting Radiofrequency Test Facility (SRFTF). The scope of the system is to support the SNS cryomodule test and cavity test at 2-K (using vacuum pump) and 4.5K for the maintenance purpose and Power Upgrade Project of SNS, and to provide the part of the cooling power needed to backup the current CHL to keep Linac at 4.5-K during CHL maintenance period in the future. The system is constructed in multiple phases. The first phase is to construct an independent 4K helium refrigeration system with helium Dewar and distribution box as load interface. It is schedule to be commissioned in 2013. Here we report the concept design of the system and the status of the first phase of this project.

  11. The Exon-Florio National Security Test for Foreign Investment

    National Research Council Canada - National Science Library

    Jackson, James K

    2006-01-01

    .... While the United States actively promotes internationally the policy of relaxing rules concerning foreign investment, including the national treatment of foreign firms, some Members of Congress...

  12. Predictors of Academic Success for the National Board Dental Hygiene Examination and the Southern Regional Testing Agency Clinical Exam

    Science.gov (United States)

    Efurd, Melissa G.

    2012-01-01

    The purpose for conducting this study was to investigate and describe the relationship between applicant criteria for a dental hygiene program and subsequent outcomes on credentialing exams: the National Board Dental Hygiene Exam and the Southern Regional Testing Agency clinical exam. Because admission criteria play a crucial role in applicant…

  13. National Prociency Testing Result of CYP2D6*10 Genotyping for Adjuvant Tamoxifen Therapy in China.

    Directory of Open Access Journals (Sweden)

    Guigao Lin

    Full Text Available Tamoxifen has been successfully used for treating breast cancer and preventing cancer recurrence. Cytochrome P450 2D6 (CYP2D6 plays a key role in the process of metabolizing tamoxifen to its active moiety, endoxifen. Patients with variants of the CYP2D6 gene may not receive the full benefit of tamoxifen treatment. The CYP2D6*10 variant (the most common variant in Asians was analyzed to optimize the prescription of tamoxifen in China. To ensure referring clinicians have accurate information for genotype-guided tamoxifen treatment, the Chinese National Center for Clinical Laboratories (NCCL organized a national proficiency testing (PT to evaluate the performance of laboratories providing CYP2D6*10 genotyping. Ten genomic DNA samples with CYP2D6 wild-type or CYP2D6*10 variants were validated by PCR-sequencing and sent to 28 participant laboratories. The genotyping results and pharmacogenomic test reports were submitted and evaluated by NCCL experts. Additional information regarding the number of samples tested, the accreditation/certification status, and detecting technology was also requested. Thirty-one data sets were received, with a corresponding analytical sensitivity of 98.2% (548/558 challenges; 95% confidence interval: 96.7-99.1% and an analytic specificity of 96.5% (675/682; 95% confidence interval: 97.9-99.5%. Overall, 25/28 participants correctly identified CYP2D6*10 status in 10 samples; however, two laboratories made serious genotyping errors. Most of the essential information was included in the 20 submitted CYP2D6*10 test reports. The majority of Chinese laboratories are reliable for detecting the CYP2D6*10 variant; however, several issues revealed in this study underline the importance of PT schemes in continued external assessment and provision of guidelines.

  14. Testing Hubbert

    International Nuclear Information System (INIS)

    Brandt, Adam R.

    2007-01-01

    The Hubbert theory of oil depletion, which states that oil production in large regions follows a bell-shaped curve over time, has been cited as a method to predict the future of global oil production. However, the assumptions of the Hubbert method have never been rigorously tested with a large, publicly available data set. In this paper, three assumptions of the modern Hubbert theory are tested using data from 139 oil producing regions. These regions are sub-national (United States state-level, United States regional-level), national, and multi-national (subcontinental and continental) in scale. We test the assumption that oil production follows a bell-shaped curve by generating best-fitting curves for each region using six models and comparing the quality of fit across models. We also test the assumptions that production over time in a region tends to be symmetric, and that production is more bell-shaped in larger regions than in smaller regions

  15. The National Criticality Experiments Research Center at the Device Assembly Facility, Nevada National Security Site: Status and Capabilities, Summary Report

    International Nuclear Information System (INIS)

    Bragg-Sitton, S.; Bess, J.; Werner, J.

    2011-01-01

    The National Criticality Experiments Research Center (NCERC) was officially opened on August 29, 2011. Located within the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS), the NCERC has become a consolidation facility within the United States for critical configuration testing, particularly those involving highly enriched uranium (HEU). The DAF is a Department of Energy (DOE) owned facility that is operated by the National Nuclear Security Agency/Nevada Site Office (NNSA/NSO). User laboratories include the Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL). Personnel bring their home lab qualifications and procedures with them to the DAF, such that non-site specific training need not be repeated to conduct work at DAF. The NNSS Management and Operating contractor is National Security Technologies, LLC (NSTec) and the NNSS Safeguards and Security contractor is Wackenhut Services. The complete report provides an overview and status of the available laboratories and test bays at NCERC, available test materials and test support configurations, and test requirements and limitations for performing sub-critical and critical tests. The current summary provides a brief summary of the facility status and the method by which experiments may be introduced to NCERC.

  16. 25th Test and Evaluation National Conference

    Science.gov (United States)

    2009-03-05

    assembly area.] • Load Aircraft and Weapon Status Check. • Lineup for takeoff. – Execute Mission [R and A mission executed as requested by ground... sequential testing and the sharing of high-demand testing assets Negative impact on ability to successfully execute complex programs: Massive

  17. Quality Teaching in Addressing Student Achievement: A Comparative Study between National Board Certified Teachers and Other Teachers on the Kentucky Core Content Test Results

    Science.gov (United States)

    Buecker, Harrie Lynne

    2010-01-01

    This dissertation focused on the link between quality teaching and its potential impact on student achievement. National Board Certification is used to represent quality teaching and student achievement is measured by the Kentucky Core Content Test. Data were gathered on the reading and mathematics scores of students of National Board Teachers who…

  18. Wind forecasting for grid code compliance

    Energy Technology Data Exchange (ETDEWEB)

    Vanitha, V.; Kishore, S.R.N. [Amrita Vishwa Vidyapeetham Univ.. Dept. of Electrical and Electronics Engineering, Coimbatore (India)

    2012-07-01

    This work explores Adaptive Neuro-Fuzzy Inference Systems (ANFIS) to forecast the average hourly wind speed. To determine the characteristics of ANFIS that best suited the target wind speed forecasting system, several ANFIS models were trained, tested and compared. Different types and number of inputs, training and checking sizes, type and number of membership functions and techniques to generate the initial (FIS) were analyzed. Comparisons with other forecasting methods were analyzed the models were given wind speed, direction and air pressure as inputs having the best forecasting accuracy. SCADA system is utilized to obtain the wind speed to the forecasting system in the host computer where ANFIS is present. The SCADA is located in the central room, the substation of the wind farm, or even at a remote off site point. The data obtained from the site is plotted at every instant and the predicted wind speed is displayed and also exported to the excel sheet which will be sent/e-mailed in the form of Graphs and excel sheets to the operator, State load dispatch centre (SLDC) and to the customer. (Author)

  19. Satellite communication on pipeline supervision using TCP-IP Protocol; Comunicacao via satelite na supervisao de dutos usando o protocolo TCP-IP

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Agliberto Pessoa da [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil); Brunette, Sergio Henrique de Moraes

    2003-07-01

    Bit transparent type or X-25 protocols have been used in VSAT satellite communication by PETROBRAS pipeline Supervisory Control and Data Acquisition System (SCADA) as access protocol. Both solutions have inconveniences. By the first one, difficulties exist for analysis and diagnosis of connection flaws, and therefore, for a ready identification by the system management stations of abnormality location. On the other hand, the usage of the X-25 brings an additional over-head in the communication since this is not an available option in most of the equipment that compose the SCADA. The access to VSAT through Ethernet, in the opposite, makes available all networks management tools of the TCP/IP platform and it allows a direct connection to the field devices, since the main models of the several makers of Programmable Controllers and Remote Terminal Units have Ethernet port. An additional earnings is the possibility of standardization that this solution allows. This paper describes a series of communication tests between two Programmable Controllers communicating through the satellite, using a protocol over Ethernet/TCP/IP. (author)

  20. Safeguarding information intensive critical infrastructures against novel types of emerging failures

    International Nuclear Information System (INIS)

    Balducelli, C.; Bologna, S.; Lavalle, L.; Vicoli, G.

    2007-01-01

    The complexity of information intensive critical infrastructures, like electricity networks, telecommunication networks and public transportation networks is today augmented much more than in the past: such complexity augments the number of possible failures and anomalous working conditions and consequently decreases the survivability of the infrastructures. In this paper, the possibility is investigated to detect early anomalies and failures inside information intensive critical infrastructures by the introduction of anomaly detectors being 'self-aware' about the normal working conditions of the infrastructure itself. This approach has the objective to improve the performance of the most popular signature-based algorithms for intrusion detection, and makes use of different classes of time-oriented algorithms based on artificial intelligence paradigm. It has the advantage to work also in presence of unknown and unexpected types of attacks or failures. The tests, to evaluate the performance of the utilised detectors, are executed inside an emulated supervisory control and data acquisition (SCADA) system of an electrical power transmission grid, and a proposal for the future integration inside real SCADA systems is also reported

  1. Safeguarding information intensive critical infrastructures against novel types of emerging failures

    Energy Technology Data Exchange (ETDEWEB)

    Balducelli, C. [ENEA-Italian National Agency for new Technology, Energy and the Environment Via Anguillasere 301, 00060 Rome (Italy)]. E-mail: claudio.balducelli@casaccia.enea.it; Bologna, S. [ENEA-Italian National Agency for new Technology, Energy and the Environment Via Anguillasere 301, 00060 Rome (Italy); Lavalle, L. [ENEA-Italian National Agency for new Technology, Energy and the Environment Via Anguillasere 301, 00060 Rome (Italy); Vicoli, G. [ENEA-Italian National Agency for new Technology, Energy and the Environment Via Anguillasere 301, 00060 Rome (Italy)

    2007-09-15

    The complexity of information intensive critical infrastructures, like electricity networks, telecommunication networks and public transportation networks is today augmented much more than in the past: such complexity augments the number of possible failures and anomalous working conditions and consequently decreases the survivability of the infrastructures. In this paper, the possibility is investigated to detect early anomalies and failures inside information intensive critical infrastructures by the introduction of anomaly detectors being 'self-aware' about the normal working conditions of the infrastructure itself. This approach has the objective to improve the performance of the most popular signature-based algorithms for intrusion detection, and makes use of different classes of time-oriented algorithms based on artificial intelligence paradigm. It has the advantage to work also in presence of unknown and unexpected types of attacks or failures. The tests, to evaluate the performance of the utilised detectors, are executed inside an emulated supervisory control and data acquisition (SCADA) system of an electrical power transmission grid, and a proposal for the future integration inside real SCADA systems is also reported.

  2. The malaria testing and treatment landscape in Kenya: results from a nationally representative survey among the public and private sector in 2016.

    Science.gov (United States)

    Musuva, Anne; Ejersa, Waqo; Kiptui, Rebecca; Memusi, Dorothy; Abwao, Edward

    2017-12-21

    Since 2004, Kenya's national malaria treatment guidelines have stipulated artemisinin-based combination therapy (ACT) as first-line treatment for uncomplicated malaria, and since 2014, confirmatory diagnosis of malaria in all cases before treatment has been recommended. A number of strategies to support national guidelines have been implemented in the public and private sectors in recent years. A nationally-representative malaria outlet survey, implemented across four epidemiological zones, was conducted between June and August 2016 to provide practical evidence to inform strategies and policies in Kenya towards achieving national malaria control goals. A total of 17,852 outlets were screened and 2271 outlets were eligible and interviewed. 78.3% of all screened public health facilities stocked both malaria diagnostic testing and quality-assured ACT (QAACT). Sulfadoxine-pyrimethamine (SP) for intermittent preventive treatment in pregnancy was available in 70% of public health facilities in endemic areas where it is recommended for treatment. SP was rarely found in the public sector outside of the endemic areas (private sector had lower levels of QAACT (46.7%) and malaria blood testing (20.8%) availability but accounted for majority of anti-malarial distribution (70.6% of the national market share). More than 40% of anti-malarials were distributed by unregistered pharmacies (37.3%) and general retailers (7.1%). QAACT accounted for 58.2% of the total anti-malarial market share, while market share for non-QAACT was 15.8% and for SP, 24.8%. In endemic areas, 74.9% of anti-malarials distributed were QAACT. Elsewhere, QAACT market share was 49.4% in the endemic-prone areas, 33.2% in seasonal-transmission areas and 37.9% in low-risk areas. Although public sector availability of QAACT and malaria diagnosis is relatively high, there is a gap in availability of both testing and treatment that must be addressed. The private sector in Kenya, where the majority of anti

  3. Leak testing plan for the Oak Ridge National Laboratory liquid low- level waste system (active tanks)

    International Nuclear Information System (INIS)

    Douglas, D.G.; Wise, R.F.; Starr, J.W.; Maresca, J.W. Jr.

    1992-06-01

    A leak testing plan for a portion of the Liquid Low-Level Waste (LLLW) system at the Oak Ridge National Laboratory (ORNL) is provided in the two volumes that form this document. This plan was prepared in response to the requirements of the Federal Facilities Agreement (FFA) between the US Department of Energy and two other agencies, the US Environmental Protection Agency (EPA) and the Tennessee Department of Environment and Conservation (TDEC). The effective date of this agreement was 1 January 1992. The LLLW system is an interconnected complex of tanks and pipelines. The FFA distinguishes four different categories of tank and pipeline systems within this complex: new systems (Category A), doubly contained systems (Category B), singly contained systems (Category C), and inactive systems (Category D). The FFA's specific requirements for leak testing of the Category C systems is addressed in this plan. The plan also addresses leak testing of the Category B portions of the LLLW system. Leak testing of the Category B components was brought into the plan to supplement the secondary containment design demonstration effort that is under way for these components

  4. Sub-Scale Orion Parachute Test Results from the National Full-Scale Aerodynamics Complex 80- By 120-ft Wind Tunnel

    Science.gov (United States)

    Anderson, Brian P.; Greathouse, James S.; Powell, Jessica M.; Ross, James C.; Schairer, Edward T.; Kushner, Laura; Porter, Barry J.; Goulding, Patrick W., II; Zwicker, Matthew L.; Mollmann, Catherine

    2017-01-01

    A two-week test campaign was conducted in the National Full-Scale Aerodynamics Complex 80 x 120-ft Wind Tunnel in support of Orion parachute pendulum mitigation activities. The test gathered static aerodynamic data using an instrumented, 3-tether system attached to the parachute vent in combination with an instrumented parachute riser. Dynamic data was also gathered by releasing the tether system and measuring canopy performance using photogrammetry. Several canopy configurations were tested and compared against the current Orion parachute design to understand changes in drag performance and aerodynamic stability. These configurations included canopies with varying levels and locations of geometric porosity as well as sails with increased levels of fullness. In total, 37 runs were completed for a total of 392 data points. Immediately after the end of the testing campaign a down-select decision was made based on preliminary data to support follow-on sub-scale air drop testing. A summary of a more rigorous analysis of the test data is also presented.

  5. 'Experience with decommissioning of research and test reactors at Argonne National Laboratory'

    International Nuclear Information System (INIS)

    Bhattacharyya, S.K.; Yule, T.J.; Fellhauer, C.R.; Boing, L.E.

    2002-01-01

    A large number of research reactors around the world have reached the end of their useful operational life. Many of these are kept in a controlled storage mode awaiting decontamination and decommissioning (D and D). At Argonne National Laboratory located near Chicago in the United States of America, significant experience has been gained in the D and D of research and test reactors. These experiences span the entire range of activities in D and D - from planning and characterization of the facilities to the eventual disposition of all waste. A multifaceted D nd D program has been in progress at the Argonne National Laboratory - East site for nearly a decade. The program consists of three elements: - D and D of nuclear facilities on the site that have reached the end of their useful life; - Development and demonstrations of technologies that help in safe and cost effective D and D; - Presentation of training courses in D and D practices. Nuclear reactor facilities have been constructed and operated at the ANL-E site since the earliest days of nuclear power. As a result, a number of these early reactors reached end-of-life long before reactors on other sites and were ready for D and D earlier. They presented an excellent set of test beds on which D and D practices and technologies could be demonstrated in environments that were similar to commercial reactors, but considerably less hazardous. As shown, four reactor facilities, plutonium contaminated glove boxes and hot cells, a cyclotron facility and assorted other nuclear related facilities have been decommissioned in this program. The overall cost of the program has been modest relative to the cost of comparable projects undertaken both in the U.S. and abroad. The safety record throughout the program was excellent. Complementing the actual operations, a set of D and D technologies are being developed. These include robotic methods of tool handling and operation, chemical and laser decontamination techniques, sensors

  6. Guard News - The National Guard

    Science.gov (United States)

    operations during chemical attack May 25, 2018 - SWANTON, Ohio - Maintenance is a critical component in Leaders discuss future of National Guard cyber warfare May 21, 2018 - CAMP ATTERBURY, Ind. - While National Guard teams from across the nation tested themselves on their cyber defensive capabilities at

  7. HISTORICAL AMERICAN ENGINEERING RECORD - IDAHO NATIONAL ENGINEERING AND ENVIRONMENTAL LABORATORY, TEST AREA NORTH, HAER NO. ID-33-E

    Energy Technology Data Exchange (ETDEWEB)

    Susan Stacy; Hollie K. Gilbert

    2005-02-01

    Test Area North (TAN) was a site of the Aircraft Nuclear Propulsion (ANP) Project of the U.S. Air Force and the Atomic Energy Commission. Its Cold War mission was to develop a turbojet bomber propelled by nuclear power. The project was part of an arms race. Test activities took place in five areas at TAN. The Assembly & Maintenance area was a shop and hot cell complex. Nuclear tests ran at the Initial Engine Test area. Low-power test reactors operated at a third cluster. The fourth area was for Administration. A Flight Engine Test facility (hangar) was built to house the anticipated nuclear-powered aircraft. Experiments between 1955-1961 proved that a nuclear reactor could power a jet engine, but President John F. Kennedy canceled the project in March 1961. ANP facilities were adapted for new reactor projects, the most important of which were Loss of Fluid Tests (LOFT), part of an international safety program for commercial power reactors. Other projects included NASA's Systems for Nuclear Auxiliary Power and storage of Three Mile Island meltdown debris. National missions for TAN in reactor research and safety research have expired; demolition of historic TAN buildings is underway.

  8. HISTORICAL AMERICAN ENGINEERING RECORD - IDAHO NATIONAL ENGINEERING AND ENVIRONMENTAL LABORATORY, TEST AREA NORTH, HAER NO. ID-33-E

    International Nuclear Information System (INIS)

    Susan Stacy; Hollie K. Gilbert

    2005-01-01

    Test Area North (TAN) was a site of the Aircraft Nuclear Propulsion (ANP) Project of the U.S. Air Force and the Atomic Energy Commission. Its Cold War mission was to develop a turbojet bomber propelled by nuclear power. The project was part of an arms race. Test activities took place in five areas at TAN. The Assembly and Maintenance area was a shop and hot cell complex. Nuclear tests ran at the Initial Engine Test area. Low-power test reactors operated at a third cluster. The fourth area was for Administration. A Flight Engine Test facility (hangar) was built to house the anticipated nuclear-powered aircraft. Experiments between 1955-1961 proved that a nuclear reactor could power a jet engine, but President John F. Kennedy canceled the project in March 1961. ANP facilities were adapted for new reactor projects, the most important of which were Loss of Fluid Tests (LOFT), part of an international safety program for commercial power reactors. Other projects included NASA's Systems for Nuclear Auxiliary Power and storage of Three Mile Island meltdown debris. National missions for TAN in reactor research and safety research have expired; demolition of historic TAN buildings is underway

  9. Impact of the Shodan Computer Search Engine on Internet-facing Industrial Control System Devices

    Science.gov (United States)

    2014-03-27

    SSL 995 POP3+SSL 1023 Telnet 1434 MS-SQL Port Service 1900 UPnP 2323 Telnet 3306 MySQL 3389 RDP 5000 Synology 5001 Synology 5432 PostgreSQL 5560 Oracle...capture mode, Digital Bond SCADA IDS signatures, Sebek, Argus, Walleye, and MySQL [13]. Honeywall report generation includes top ten scanned ports, the top...Sleuth: A Course in Methods of Data Analysis: A Course in Methods of Data Analysis. Cengage Learning, Boston MA, 2012. [41] Rrushi, J. SCADA protocol

  10. Preliminary data from an instantaneous profile test conducted near the Mixed Waste Landfill, Technical Area 3, Sandia National Laboratories/New Mexico

    International Nuclear Information System (INIS)

    Bayliss, S.C.; Goering, T.J.; McVey, M.D.; Strong, W.R.; Peace, J.L.

    1996-04-01

    This paper presents data from an instantaneous profile test conducted near the Sandia National Laboratories/New Mexico Mixed Waste Landfill in Technical Area 3. The test was performed from December 1993 through 1995 as part of the environmental Restoration Project's Phase 2 RCRA Facility Investigation of the Mixed Waste Landfill. The purpose of the test was to measure the unsaturated hydraulic properties of soils near the Mixed Waste Landfill. The instantaneous profile test and instrumentation are described, and the pressure and moisture content data from the test are presented. These data may be useful for understanding the unsaturated hydraulic properties of soils in Technical Area 3 and for model validation, verification, and calibration

  11. 2015 Annual Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Ponds

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Michael George [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-02-01

    This report describes conditions and information, as required by the state of Idaho, Department of Environmental Quality Reuse Permit I-161-02, for the Advanced Test Reactor Complex Cold Waste Ponds located at Idaho National Laboratory from November 1, 2014–October 31, 2015. The effective date of Reuse Permit I-161-02 is November 20, 2014 with an expiration date of November 19, 2019.

  12. Tonopah test range - outpost of Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, L.

    1996-03-01

    Tonopah Test Range is a unique historic site. Established in 1957 by Sandia Corporation, Tonopah Test Range in Nevada provided an isolated place for the Atomic Energy Commission to test ballistics and non-nuclear features of atomic weapons. It served this and allied purposes well for nearly forty years, contributing immeasurably to a peaceful conclusion to the long arms race remembered as the Cold War. This report is a brief review of historical highlights at Tonopah Test Range. Sandia`s Los Lunas, Salton Sea, Kauai, and Edgewood testing ranges also receive abridged mention. Although Sandia`s test ranges are the subject, the central focus is on the people who managed and operated the range. Comments from historical figures are interspersed through the narrative to establish this perspective, and at the end a few observations concerning the range`s future are provided.

  13. UK National Data Centre archive of seismic recordings of (presumed) underground nuclear tests 1964-1996

    Science.gov (United States)

    Young, John; Peacock, Sheila

    2016-04-01

    The year 1996 has particular significance for forensic seismologists. This was the year when the Comprehensive Test Ban Treaty (CTBT) was signed in September at the United Nations, setting an international norm against nuclear testing. Blacknest, as a long time seismic centre for research into detecting and identifying underground explosions using seismology, provided significant technical advice during the CTBT negotiations. Since 1962 seismic recordings of both presumed nuclear explosions and earthquakes from the four seismometer arrays Eskdalemuir, Scotland (EKA), Yellowknife, Canada (YKA), Gauribidanur, India (GBA), and Warramunga, Australia (WRA) have been copied, digitised, and saved. There was a possibility this archive would be lost. It was decided to process the records and catalogue them for distribution to other groups and institutions. This work continues at Blacknest but the archive is no longer under threat. In addition much of the archive of analogue tape recordings has been re-digitised with modern equipment, allowing sampling rates of 100 rather than 20 Hz.

  14. Trends in HIV testing and associated factors among men in South Africa: evidence from 2005, 2008 and 2012 national population-based household surveys.

    Science.gov (United States)

    Makusha, T; Mabaso, M; Richter, L; Desmond, C; Jooste, S; Simbayi, L

    2017-02-01

    In Sub-Saharan African countries, including South Africa, uptake of human immunodeficiency virus (HIV) testing among men remains a major challenge. Few studies have explored HIV testing uptake among men and factors that influence their testing behaviours. This article explores trends in HIV testing uptake and associated factors among men aged 15 years and older in South Africa using national HIV population-based household surveys conducted in 2005, 2008 and 2012. A multistage cross-sectional design was used in the three nationally representative household-based surveys. P-trend Chi-squared statistic was used to analyze changes in HIV testing in relation to demographic factors, and HIV-related risk behaviours across the three surveys. Univariate and multivariate logistic regression models were used to assess the associations between ever testing for HIV, demographic factors and HIV-related risk behaviours. HIV testing uptake among men was 28% in 2005, 43% in 2008 and 59% in 2012. A trend was also observed in HIV testing by sociodemographic factors, but differences existed within variables. HIV testing uptake was mainly influenced by the effects of selected population characteristics. Reduced likelihood of HIV testing was significantly associated with males aged 15-24 years, Black African race group, being single and unemployed, those residing in urban informal and rural informal areas, and those men who ever had sex. The observed sociodemographic differentials suggest that an effective expansion strategy for HIV testing needs to prioritize those most unlikely to test as identified by the current findings. Copyright © 2016 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  15. Cost estimate of grouting the proposed test pits at Idaho National Engineering Laboratory using the ORNL-recommended grouts

    International Nuclear Information System (INIS)

    Spence, R.D.

    1987-08-01

    EG and G Idaho will construct three experimental pits to simulate the TRU waste trenches at Idaho National Engineering Laboratory (INEL). Two of these pits will be grouted and then one will be destructively examined as soon as the grout cures and the other will be monitored for 10 years. Oak Ridge National Laboratory (ORNL) is evaluating grouts and will recommend a grout to EG and G Idaho to reduce the permeability of the pit, fill the large voids, and encapsulate the waste. A previous ORNL report (ORNL/TM-9881) discusses the grouts evaluated and the grout recommended based on those evaluations. This report evaluates the economics of grouting the experimental pits. The cost of double grouting two of the EG and G Idaho design pits at the Idaho National Engineering Laboratory using lance injection was estimated to be $100,000. Jet grouting the same two pits was estimated to cost $85,000. Both should be tried as part of the test EG and G Idaho is conducting

  16. Simulation of wake effects between two wind farms

    International Nuclear Information System (INIS)

    Hansen, K S; Réthoré, P-E; Peña, A; Ott, S; Van der Laan, M P; Volker, P; Palma, J; Hevia, B G; Prospathopoulos, J; Schepers, G; Palomares, A

    2015-01-01

    SCADA data, recorded on the downstream wind farm, has been used to identify flow cases with visible clustering effects. The inflow condition is derived from a partly undisturbed wind turbine, due to lack of mast measurements. The SCADA data analysis concludes that centre of the deficit for the downstream wind farm with disturbed inflow has a distinct visible maximum deficit zone located only 5-10D downstream from the entrance. This zone, representing 20-30% speed reduction, increases and moves downstream for increasing cluster effect and is not visible outside a flow sector of 20-30°. The eight flow models represented in this benchmark include both RANS models, mesoscale models and engineering models. The flow cases, identified according to the wind speed level and inflow sector, have been simulated and validated with the SCADA results. The model validation concludes that all models more or less are able to predict the location and size of the deficit zone inside the downwind wind farm. (paper)

  17. A novel intrusion detection method based on OCSVM and K-means recursive clustering

    Directory of Open Access Journals (Sweden)

    Leandros A. Maglaras

    2015-01-01

    Full Text Available In this paper we present an intrusion detection module capable of detecting malicious network traffic in a SCADA (Supervisory Control and Data Acquisition system, based on the combination of One-Class Support Vector Machine (OCSVM with RBF kernel and recursive k-means clustering. Important parameters of OCSVM, such as Gaussian width o and parameter v affect the performance of the classifier. Tuning of these parameters is of great importance in order to avoid false positives and over fitting. The combination of OCSVM with recursive k- means clustering leads the proposed intrusion detection module to distinguish real alarms from possible attacks regardless of the values of parameters o and v, making it ideal for real-time intrusion detection mechanisms for SCADA systems. Extensive simulations have been conducted with datasets extracted from small and medium sized HTB SCADA testbeds, in order to compare the accuracy, false alarm rate and execution time against the base line OCSVM method.

  18. Cross-National Yardstick Comparisons

    DEFF Research Database (Denmark)

    Møller Hansen, Kasper; Leth Olsen, Asmus; Bech, Mickael

    2015-01-01

    performance comparisons—even when accounting for classic national sociotropic and egotropic items. Specifically, voters respond strongly to how the prospective wealth of Denmark evolves relative to the neighboring Sweden. Interestingly, voters are more negative in their response to cross-national losses......Comparing performance between countries is both a theoretically and intuitively useful yardstick for voters. Cross-national comparisons provide voters with heuristics that are less cognitively demanding, less ambiguous, and less uncertain than solely national, absolute performance measurements. We...... test this proposition using a unique, choice experiment embedded in the 2011 Danish National Election Study. This design allows to contrast cross-national comparisons with more traditional national sociotropic and egotropic concerns. The findings suggest that voters are strongly influenced by cross-national...

  19. 75 FR 47817 - Notice of Availability: Test Tools and Test Procedures Approved for the Office of the National...

    Science.gov (United States)

    2010-08-09

    ..., Implementation Specifications, and Certification Criteria for Electronic Health Record Technology'' (HIT... Approved for the Office of the National Coordinator for Health Information Technology (ONC) Temporary Certification Program AGENCY: Office of the National Coordinator for Health Information Technology, Office of...

  20. Awareness of cancer susceptibility genetic testing: the 2000, 2005, and 2010 National Health Interview Surveys.

    Science.gov (United States)

    Mai, Phuong L; Vadaparampil, Susan Thomas; Breen, Nancy; McNeel, Timothy S; Wideroff, Louise; Graubard, Barry I

    2014-05-01

    Genetic testing for several cancer susceptibility syndromes is clinically available; however, existing data suggest limited population awareness of such tests. To examine awareness regarding cancer genetic testing in the U.S. population aged ≥25 years in the 2000, 2005, and 2010 National Health Interview Surveys. The weighted percentages of respondents aware of cancer genetic tests, and percent changes from 2000-2005 and 2005-2010, overall and by demographic, family history, and healthcare factors were calculated. Interactions were used to evaluate the patterns of change in awareness between 2005 and 2010 among subgroups within each factor. To evaluate associations with awareness in 2005 and 2010, percentages were adjusted for covariates using multiple logistic regression. The analysis was performed in 2012. Awareness decreased from 44.4% to 41.5% (pAwareness increased between 2005 and 2010 in most subgroups, particularly among individuals in the South (pinteraction=0.03) or with a usual place of care (pinteraction=0.01). In 2005 and 2010, awareness was positively associated with personal or family cancer history and high perceived cancer risk, and inversely associated with racial/ethnic minorities, age 25-39 or ≥60 years, male gender, lower education and income levels, public or no health insurance, and no provider contact in 12 months. Despite improvement from 2005 to 2010, ≤50% of the U.S. adult population was aware of cancer genetic testing in 2010. Notably, disparities persist for racial/ethnic minorities and individuals with limited health care access or income. Published by Elsevier Inc.

  1. The Control System of CERN Accelerators Vacuum (Current Status and Recent Improvements)

    CERN Document Server

    Gomes, P; Blanchard, S; Boccioli, M; Girardot, G; Vestergard, H; Kopylov, L; Mikheev, M

    2011-01-01

    The vacuum control system of most of the CERN accelerators is based on Siemens PLCs and on PVSS SCADA. After the transition from the LHC commissioning phase to its regular operation, there has been a number of additions and improvements to the vacuum control system. They were driven by new technical requirements and by feedback from the accelerator operators and vacuum specialists. New control functions have been implemented in the PLCs; new tools have been developed for the SCADA, while its ergonomics and navigation have been enhanced.

  2. A ground-based magnetic survey of Frenchman Flat, Nevada National Security Site and Nevada Test and Training Range, Nevada: data release and preliminary interpretation

    Science.gov (United States)

    Phillips, Jeffrey D.; Burton, Bethany L.; Curry-Elrod, Erika; Drellack, Sigmund

    2014-01-01

    The Nevada National Security Site (NNSS, formerly the Nevada Test Site) is located in southern Nevada approximately 105 kilometers (km) (65 miles) northwest of Las Vegas. Frenchman Flat is a sedimentary basin located on the eastern edge of NNSS and extending eastward into the adjacent Nevada Test and Training Range (NTTR).

  3. A National Survey of Spanish Language Testing for Placement of Outcome Assessment at B.A. -Granting Institutions in the United States.

    Science.gov (United States)

    Wherritt, Irene; Cleary, T. Anne

    1990-01-01

    Describes the results of a national survey that was conducted to determine the current state of Spanish-language testing for placement and outcome assessments. The survey was undertaken in the United States in the departments of Spanish in B.A.-granting institutions. (Author/VWL)

  4. Immediate tasks in realization of 52-53 Sessions of United Nations Organization General Assembly resolution on Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Ibraev, S.

    2000-01-01

    The author points out, that ecological heritage of Semipalatinsk test site is not studied, scattered investigations does not give objective assessment about radiation situation in the region. Only operations of close down of wells on the base of inter-state agreement between Republic of Kazakhstan and the United States of America were carried out. There are following main rehabilitation measures on liquidation of nuclear tests consequences in the region: study, deactivation and re-cultivation of populated territories; study of radioactive contamination level in underground waters and definition radionuclides migration by biological chain for taking preventative measures. It is noted, that citizens of the region with gratitude took solution of 52-53 Sessions of United Nations Organization General Assembly 'On liquidation of nuclear tests consequences on Semipalatinsk nuclear test site

  5. Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Potable Water System Operations Plan

    Energy Technology Data Exchange (ETDEWEB)

    Ocampo, Ruben P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bellah, Wendy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-03-04

    The existing Lawrence Livermore National Laboratory (LLNL) Site 300 drinking water system operation schematic is shown in Figures 1 and 2 below. The sources of water are from two Site 300 wells (Well #18 and Well #20) and San Francisco Public Utilities Commission (SFPUC) Hetch-Hetchy water through the Thomas shaft pumping station. Currently, Well #20 with 300 gallons per minute (gpm) pump capacity is the primary source of well water used during the months of September through July, while Well #18 with 225 gpm pump capacity is the source of well water for the month of August. The well water is chlorinated using sodium hypochlorite to provide required residual chlorine throughout Site 300. Well water chlorination is covered in the Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Chlorination Plan (“the Chlorination Plan”; LLNL-TR-642903; current version dated August 2013). The third source of water is the SFPUC Hetch-Hetchy Water System through the Thomas shaft facility with a 150 gpm pump capacity. At the Thomas shaft station the pumped water is treated through SFPUC-owned and operated ultraviolet (UV) reactor disinfection units on its way to Site 300. The Thomas Shaft Hetch- Hetchy water line is connected to the Site 300 water system through the line common to Well pumps #18 and #20 at valve box #1.

  6. Practical Testing and Performance Analysis of Phasor Measurement Unit Using Real Time Digital Simulator (RTDS)

    DEFF Research Database (Denmark)

    Liu, Leo; Rather, Zakir Hussain; Stearn, Nathen

    2012-01-01

    Wide Area Measurement Systems (WAMS) and Wide Area Monitoring, Protection and Control Systems (WAMPACS) have evolved rapidly over the last two decades [1]. This fast emerging technology enables real time synchronized monitoring of power systems. Presently, WAMS are mainly used for real time...... visualisation and post event analysis of power systems. It is expected however, that through integration with traditional Supervisory Control and Data Acquisition (SCADA) systems, closed loop control applications will be possible. Phasor Measurement Units (PMUs) are fundamental components of WAMS. Large WAMS...... proposed to realize highly precise phasoreasurements. Further a comparative study based on features of PMUs from different major manufacturers is presented. The selection of optimal parameters, such as phasor format and filter length is also discussed for various applications....

  7. Addressing Achievement Gaps: Educational Testing in America: State Assessments, Achievement Gaps, National Policy and Innovations. ETS Policy Notes. Volume 17, Number 1, Winter 2009

    Science.gov (United States)

    Yaffe, Deborah; Coley, Richard J., Ed.; Pliskin, Richard, Ed.

    2009-01-01

    Annual standardized testing lies at the heart of the accountability system that American education reformers and policymakers have established during the past decade in an effort to ensure equal opportunity for all students, no matter their race, ethnicity or wealth. The new testing regime has brought national attention to the schooling of…

  8. 2015 Annual Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Ponds

    International Nuclear Information System (INIS)

    Lewis, Michael George

    2016-01-01

    This report describes conditions and information, as required by the state of Idaho, Department of Environmental Quality Reuse Permit I-161-02, for the Advanced Test Reactor Complex Cold Waste Ponds located at Idaho National Laboratory from November 1, 2014-October 31, 2015. The effective date of Reuse Permit I-161-02 is November 20, 2014 with an expiration date of November 19, 2019.

  9. Proposals for ORNL [Oak Ridge National Laboratory] support to Tiber LLNL [Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Berry, L.A.; Rosenthal, M.W.; Saltmarsh, M.J.; Shannon, T.E.; Sheffield, J.

    1987-01-01

    This document describes the interests and capabilities of Oak Ridge National Laboratory in their proposals to support the Lawrence Livermore National Laboratory (LLNL) Engineering Test Reactor (ETR) project. Five individual proposals are cataloged separately. (FI)

  10. Monitoring and control of power grids; Ueberwachung und Steuerung in Energietransportnetzen

    Energy Technology Data Exchange (ETDEWEB)

    Schunk, Peter [Keymile GmbH, Hannover (Germany). Bereich Technisches Consulting

    2010-07-01

    Electric and gas utilities often transport and distribute their products over long distances. Typical examples are natural gas grids or the high voltage grids of electric utilities, fresh water or oil pipeline systems. Reliable operation of these networks requires efficient monitoring and control of the complex technical equipment. The sum of these functions is referred to as Scada (Supervisory Control And Data Acquisition). Communication between different SCADA stations in most cases is linked to an existing (or planned) communications network ''alongside the lines''. (orig.)

  11. The control system of CERN accelerators vacuum (current status and recent improvements)

    International Nuclear Information System (INIS)

    Gomes, P.; Antoniotti, F.; Blanchard, S.; Boccioli, M.; Girardot, G.; Vestergard, H.; Kopylov, L.; Mikheev, M.

    2012-01-01

    The vacuum control system of most of the CERN accelerators is based on Siemens PLCs and on PVSS SCADA. After the transition from the LHC commissioning phase to its regular operation, there has been a number of additions and improvements to the vacuum control system. They were driven by new technical requirements and by feedback from the accelerator operators and vacuum specialists. New control functions have been implemented in the PLCs; new tools have been developed for the SCADA, while its ergonomic and navigation have been enhanced. (authors)

  12. Implementing non-invasive prenatal testing for aneuploidy in a national healthcare system: global challenges and national solutions.

    Science.gov (United States)

    van Schendel, Rachèl V; van El, Carla G; Pajkrt, Eva; Henneman, Lidewij; Cornel, Martina C

    2017-09-19

    Since the introduction of non-invasive prenatal testing (NIPT) in 2011, mainly by commercial companies, a growing demand for NIPT from the public and healthcare professionals has been putting pressure on the healthcare systems of various countries. This study identifies the challenges of establishing a responsible implementation of NIPT for aneuploidy in prenatal healthcare, by looking at the Netherlands. A mixed methods approach involving 13 stakeholder interviews, document analysis and (participatory) observations of the Dutch NIPT Consortium meetings were used. The Diffusion of Innovation Theory and a Network of Actors model were used to interpret the findings. Implementation of NIPT was facilitated by several factors. The set-up of a national NIPT Consortium enabled discussion and collaboration between stakeholders. Moreover, it led to the plan to offer NIPT through a nationwide research setting (TRIDENT studies), which created a learning phase for careful implementation. The Dutch legal context was perceived as a delaying factor, but eventually gave room for the parties involved to organise themselves and their practices. This study shows that implementing advanced technologies with profound effects on prenatal care benefit from a learning phase that allows time to carefully evaluate the technical performance and women's experiences and to enable public debate. Such a coordinated learning phase, involving all stakeholders, will stimulate the process of responsible and sustainable implementation.

  13. Fatigue Test Design: Scenarios for Biaxial Fatigue Testing of a 60-Meter Wind Turbine Blade

    Energy Technology Data Exchange (ETDEWEB)

    Post, Nathan [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-07-01

    Current practice in commercial certification of wind turbine blades is to perform separate flap and lead-lag fatigue tests. The National Renewable Energy Laboratory has been researching and evaluating biaxial fatigue testing techniques and demonstrating various options, typically on smaller-scale test articles at the National Wind Technology Center. This report evaluates some of these biaxial fatigue options in the context of application to a multimegawatt blade certification test program at the Wind Technology Testing Center in Charlestown, Massachusetts.

  14. Real-time laboratory exercises to test contingency plans for classical swine fever: experiences from two national laboratories

    DEFF Research Database (Denmark)

    Koenen, K.; Uttenthal, Åse; Meindl-Böhmer, A.

    2007-01-01

    In order to adequately and efficiently handle outbreaks of contagious diseases such as classical swine fever (CSF), foot and mouth disease or highly pathogenic avian influenza, competent authorities and the laboratories involved have to be well prepared and must be in possession of functioning....... It is essential that these plans are established during ‘peace-time’ and are reviewed regularly. This paper provides suggestions on how to perform laboratory exercises to test preparedness and describes the experiences of two national reference laboratories for CSF. The major lesson learnt was the importance...

  15. U.S. Department of Energy NESHAP Annual Report for CY 2014 Sandia National Laboratories Tonopah Test Range

    Energy Technology Data Exchange (ETDEWEB)

    Evelo, Stacie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Miller, Mark L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-05-01

    This National Emission Standards for Hazardous Air Pollutants (NESHAP) Annual Report has been prepared in a format to comply with the reporting requirements of 40 CFR 61.94 and the April 5, 1995 Memorandum of Agreement (MOA) between the Department of Energy (DOE) and the Environmental Protection Agency (EPA). According to the EPA approved NESHAP Monitoring Plan for the Tonopah Test Range (TTR), 40 CFR 61, subpart H, and the MOA, no additional monitoring or measurements are required at TTR in order to demonstrate compliance with the NESHAP regulation.

  16. Cultural Resource Investigations for the Resumption of Transient Testing of Nuclear Fuels and Material at the Idaho National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Pace, Brenda R. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Williams, Julie B. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-11-01

    The U. S. Department of Energy (DOE) has a need to test nuclear fuels under conditions that subject them to short bursts of intense, high-power radiation called ‘transient testing’ in order to gain important information necessary for licensing new nuclear fuels for use in U.S. nuclear power plants, for developing information to help improve current nuclear power plant performance and sustainability, for improving the affordability of new generation reactors, for developing recyclable nuclear fuels, and for developing fuels that inhibit any repurposing into nuclear weapons. To meet this mission need, DOE is considering alternatives for re-use and modification of existing nuclear reactor facilities to support a renewed transient testing program. One alternative under consideration involves restarting the Transient Reactor Test (TREAT) reactor located at the Materials and Fuels Complex (MFC) on the Idaho National Laboratory (INL) site in southeastern Idaho. This report summarizes cultural resource investigations conducted by the INL Cultural Resource Management Office in 2013 to support environmental review of activities associated with restarting the TREAT reactor at the INL. These investigations were completed in order to identify and assess the significance of cultural resources within areas of potential effect associated with the proposed action and determine if the TREAT alternative would affect significant cultural resources or historic properties that are eligible for nomination to the National Register of Historic Places. No archaeological resources were identified in the direct area of potential effects for the project, but four of the buildings proposed for modifications are evaluated as historic properties, potentially eligible for nomination to the National Register of Historic Places. This includes the TREAT reactor (building #), control building (building #), guardhouse (building #), and warehouse (building #). The proposed re-use of these historic

  17. Power source evaluation capabilities at Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Doughty, D.H.; Butler, P.C.

    1996-04-01

    Sandia National Laboratories maintains one of the most comprehensive power source characterization facilities in the U.S. National Laboratory system. This paper describes the capabilities for evaluation of fuel cell technologies. The facility has a rechargeable battery test laboratory and a test area for performing nondestructive and functional computer-controlled testing of cells and batteries.

  18. Predictors of never testing for HIV among a national online sample of men who have sex with men in Norway.

    Science.gov (United States)

    Berg, Rigmor C

    2013-06-01

    HIV testing among persons at risk of infection has become a cornerstone in prevention and control of the HIV/AIDS epidemic. Understanding factors related to HIV testing is thus fundamental for informing prevention and testing initiatives. This study aims to identify prevalence of, and factors that are associated with, HIV testing. This study analysed data from 2011 HIV-negative and untested MSM collected in a national, online survey. More than a third (35.3%) of MSM had never received an HIV test result. Multivariate logistic regression results showed that compared with men ever tested, untested men were younger (odds ratio, OR 0.95), closeted about same sex attractions (OR 3.84), had low educational level (OR 0.47), low HIV transmission and testing knowledge (OR 0.98), did not believe that HIV testing is free (OR 0.27), had never taken a test for sexually transmitted infection (OR 0.08), and had not engaged in sex abroad in the past year (OR 0.69). These results underscore the urgency in efforts to reduce testing delay among especially young MSM and point to the need for additional public health resources and prevention marketing efforts to be directed towards increasing awareness of HIV testing.

  19. Underground Test Area Fiscal Year 2014 Annual Quality Assurance Report Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Krenzien, Susan

    2015-01-01

    This report is required by the Underground Test Area (UGTA) Quality Assurance Plan (QAP) and identifies the UGTA quality assurance (QA) activities from October 1, 2013, through September 30, 2014 (fiscal year [FY] 2014). All UGTA organizations—U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO); Desert Research Institute (DRI); Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); National Security Technologies, LLC (NSTec); Navarro-Intera, LLC (N-I); and the U.S. Geological Survey (USGS)—conducted QA activities in FY 2014. The activities included conducting oversight assessments for QAP compliance, identifying findings and completing corrective actions, evaluating laboratory performance, and publishing documents. UGTA Activity participants conducted 25 assessments on topics including safe operations, QAP compliance, activity planning, and sampling. These assessments are summarized in Section 2.0. Corrective actions tracked in FY 2014 are presented in Appendix A. Laboratory performance was evaluated based on three approaches: (1) established performance evaluation programs (PEPs), (2) interlaboratory comparisons, or (3) data review. The results of the laboratory performance evaluations, and interlaboratory comparison results are summarized in Section 4.0. The UGTA Activity published three public documents and a variety of other publications in FY 2014. The titles, dates, and main authors are identified in Section 5.0. The Contract Managers, Corrective Action Unit (CAU) Leads, Preemptive Review (PER) Committee members, and Topical Committee members are listed by name and organization in Section 6.0. Other activities that affected UGTA quality are discussed in Section 7.0. Section 8.0 provides the FY 2014 UGTA QA program conclusions, and Section 9.0 lists the references not identified in Section 5.0.

  20. Closure Report for Corrective Action Unit 116: Area 25 Test Cell C Facility, Nevada National Security Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Restoration

    2011-09-29

    This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 116, Area 25 Test Cell C Facility. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 [as amended March 2010]). CAU 116 consists of the following two Corrective Action Sites (CASs), located in Area 25 of the Nevada National Security Site: (1) CAS 25-23-20, Nuclear Furnace Piping and (2) CAS 25-41-05, Test Cell C Facility. CAS 25-41-05 consisted of Building 3210 and the attached concrete shield wall. CAS 25-23-20 consisted of the nuclear furnace piping and tanks. Closure activities began in January 2007 and were completed in August 2011. Activities were conducted according to Revision 1 of the Streamlined Approach for Environmental Restoration Plan for CAU 116 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2008). This CR provides documentation supporting the completed corrective actions and provides data confirming that closure objectives for CAU 116 were met. Site characterization data and process knowledge indicated that surface areas were radiologically contaminated above release limits and that regulated and/or hazardous wastes were present in the facility.

  1. Verification, validation, and field testing the USEPA National Stormwater Calculator

    Data.gov (United States)

    U.S. Environmental Protection Agency — We used this dataset to verify and validate functions in the USEPA National Stormwater Calculator, and then applied field data and commonly-available datasets to...

  2. National Accounts Energy Alliance : Field test and verification of CHP components and systems

    Energy Technology Data Exchange (ETDEWEB)

    Sweetser, R. [Exergy Partners Corporation, Herndon, VA (United States)

    2003-07-01

    Exergy is a consulting firm which specializes in capitalizing on opportunities that result from the nexus of utility deregulation and global climate change in both the construction and energy industries. The firm offers assistance in technical business and market planning, product development and high impact marketing and technology transfer programs. The author discussed National Accounts Energy Alliance (NAEA) program on distributed energy resources (DER) and identified some advantageous areas such as homeland security (less possible terrorist targets to be protected), food safety (protection of food supply and delivery system), reliability, power quality, energy density, grid congestion and energy price. In the future, an essential role in moderating energy prices for commercial buildings will probably be played by distributed generation (DG) and combined heat and power (CHP). The technical merits of these technologies is being investigated by national accounts and utilities partnering with non-profit organizations, the United States Department of Energy (US DOE), state governments and industry. In that light, in 2001 an Alliance program was developed, which allows investors to broaden their knowledge from the application and verification of Advanced Energy Technologies. This program was the result of a synergy between the American Gas Foundation and the Gas Technology Institute (GTI), and it assists investors with their strategic planning. It was proven that a customer-led Energy Technology Test and Verification Program (TA and VP) could be cost-effective and successful. The NAEA activities in five locations were reviewed and discussed. They were: (1) Russell Development, Portland, Oregon; (2) A and P-Waldbaums, Hauppage, New York; (3) HEB, Southern, Texas; (4) Cinemark, Plano, Texas; and McDonald's, Tampa, Florida. 4 tabs., figs.

  3. Standardised testing in South Africa: the annual national ...

    African Journals Online (AJOL)

    The primary purpose of standardized tests is to inform teaching and improve learning. Assessment is about constructive learning processes and to provide useful feedback to learners, parents and teachers. Researchers however warn of the unintended consequences of high-stakes tests, which include the narrowing of the ...

  4. Improving reliability of state estimation programming and computing suite based on analyzing a fault tree

    Directory of Open Access Journals (Sweden)

    Kolosok Irina

    2017-01-01

    Full Text Available Reliable information on the current state parameters obtained as a result of processing the measurements from systems of the SCADA and WAMS data acquisition and processing through methods of state estimation (SE is a condition that enables to successfully manage an energy power system (EPS. SCADA and WAMS systems themselves, as any technical systems, are subject to failures and faults that lead to distortion and loss of information. The SE procedure enables to find erroneous measurements, therefore, it is a barrier for the distorted information to penetrate into control problems. At the same time, the programming and computing suite (PCS implementing the SE functions may itself provide a wrong decision due to imperfection of the software algorithms and errors. In this study, we propose to use a fault tree to analyze consequences of failures and faults in SCADA and WAMS and in the very SE procedure. Based on the analysis of the obtained measurement information and on the SE results, we determine the state estimation PCS fault tolerance level featuring its reliability.

  5. Development and Demonstration of a Security Core Component

    Energy Technology Data Exchange (ETDEWEB)

    Turke, Andy

    2014-02-28

    In recent years, the convergence of a number of trends has resulted in Cyber Security becoming a much greater concern for electric utilities. A short list of these trends includes: · Industrial Control Systems (ICSs) have evolved from depending on proprietary hardware and operating software toward using standard off-the-shelf hardware and operating software. This has meant that these ICSs can no longer depend on “security through obscurity. · Similarly, these same systems have evolved toward using standard communications protocols, further reducing their ability to rely upon obscurity. · The rise of the Internet and the accompanying demand for more data about virtually everything has resulted in formerly isolated ICSs becoming at least partially accessible via Internet-connected networks. · “Cyber crime” has become commonplace, whether it be for industrial espionage, reconnaissance for a possible cyber attack, theft, or because some individual or group “has something to prove.” Electric utility system operators are experts at running the power grid. The reality is, especially at small and mid-sized utilities, these SCADA operators will by default be “on the front line” if and when a cyber attack occurs against their systems. These people are not computer software, networking, or cyber security experts, so they are ill-equipped to deal with a cyber security incident. Cyber Security Manager (CSM) was conceived, designed, and built so that it can be configured to know what a utility’s SCADA/EMS/DMS system looks like under normal conditions. To do this, CSM monitors log messages from any device that uses the syslog standard. It can also monitor a variety of statistics from the computers that make up the SCADA/EMS/DMS: outputs from host-based security tools, intrusion detection systems, SCADA alarms, and real-time SCADA values – even results from a SIEM (Security Information and Event Management) system. When the system deviates from

  6. Large Rotor Test Apparatus

    Data.gov (United States)

    Federal Laboratory Consortium — This test apparatus, when combined with the National Full-Scale Aerodynamics Complex, produces a thorough, full-scale test capability. The Large Rotor Test Apparatus...

  7. Knowledge Test

    DEFF Research Database (Denmark)

    Sørensen, Ole Henning

    1998-01-01

    The knowledge test is about competing temporal and spatial expressions of the politics of technological development and national prosperity in contemporary society. The discussion is based on literature of national systems of innovation and industrial networks of various sorts. Similarities...... and differences in the disparate theories are discussed through a critical perspective on metaphor, time, space, agency and technology. It is asserted that the process of globalization is leading to a new production of space-time perceptions and practices where localization and globalization is becoming...... increasingly important. National space is being contested and nation states need to perform differently....

  8. Introduction of Syphilis Point-of-Care Tests, from Pilot Study to National Programme Implementation in Zambia: A Qualitative Study of Healthcare Workers' Perspectives on Testing, Training and Quality Assurance.

    Directory of Open Access Journals (Sweden)

    Éimhín M Ansbro

    Full Text Available Syphilis affects 1.4 million pregnant women globally each year. Maternal syphilis causes congenital syphilis in over half of affected pregnancies, leading to early foetal loss, pregnancy complications, stillbirth and neonatal death. Syphilis is under-diagnosed in pregnant women. Point-of-care rapid syphilis tests (RST allow for same-day treatment and address logistical barriers to testing encountered with standard Rapid Plasma Reagin testing. Recent literature emphasises successful introduction of new health technologies requires healthcare worker (HCW acceptance, effective training, quality monitoring and robust health systems. Following a successful pilot, the Zambian Ministry of Health (MoH adopted RST into policy, integrating them into prevention of mother-to-child transmission of HIV clinics in four underserved Zambian districts. We compare HCW experiences, including challenges encountered in scaling up from a highly supported NGO-led pilot to a large-scale MoH-led national programme. Questionnaires were administered through structured interviews of 16 HCWs in two pilot districts and 24 HCWs in two different rollout districts. Supplementary data were gathered via stakeholder interviews, clinic registers and supervisory visits. Using a conceptual framework adapted from health technology literature, we explored RST acceptance and usability. Quantitative data were analysed using descriptive statistics. Key themes in qualitative data were explored using template analysis. Overall, HCWs accepted RST as learnable, suitable, effective tools to improve antenatal services, which were usable in diverse clinical settings. Changes in training, supervision and quality monitoring models between pilot and rollout may have influenced rollout HCW acceptance and compromised testing quality. While quality monitoring was integrated into national policy and training, implementation was limited during rollout despite financial support and mentorship. We

  9. Introduction of Syphilis Point-of-Care Tests, from Pilot Study to National Programme Implementation in Zambia: A Qualitative Study of Healthcare Workers’ Perspectives on Testing, Training and Quality Assurance

    Science.gov (United States)

    Ansbro, Éimhín M.; Gill, Michelle M.; Reynolds, Joanna; Shelley, Katharine D.; Strasser, Susan; Sripipatana, Tabitha; Ncube, Alexander Tshaka; Tembo Mumba, Grace; Terris-Prestholt, Fern; Peeling, Rosanna W.; Mabey, David

    2015-01-01

    Syphilis affects 1.4 million pregnant women globally each year. Maternal syphilis causes congenital syphilis in over half of affected pregnancies, leading to early foetal loss, pregnancy complications, stillbirth and neonatal death. Syphilis is under-diagnosed in pregnant women. Point-of-care rapid syphilis tests (RST) allow for same-day treatment and address logistical barriers to testing encountered with standard Rapid Plasma Reagin testing. Recent literature emphasises successful introduction of new health technologies requires healthcare worker (HCW) acceptance, effective training, quality monitoring and robust health systems. Following a successful pilot, the Zambian Ministry of Health (MoH) adopted RST into policy, integrating them into prevention of mother-to-child transmission of HIV clinics in four underserved Zambian districts. We compare HCW experiences, including challenges encountered in scaling up from a highly supported NGO-led pilot to a large-scale MoH-led national programme. Questionnaires were administered through structured interviews of 16 HCWs in two pilot districts and 24 HCWs in two different rollout districts. Supplementary data were gathered via stakeholder interviews, clinic registers and supervisory visits. Using a conceptual framework adapted from health technology literature, we explored RST acceptance and usability. Quantitative data were analysed using descriptive statistics. Key themes in qualitative data were explored using template analysis. Overall, HCWs accepted RST as learnable, suitable, effective tools to improve antenatal services, which were usable in diverse clinical settings. Changes in training, supervision and quality monitoring models between pilot and rollout may have influenced rollout HCW acceptance and compromised testing quality. While quality monitoring was integrated into national policy and training, implementation was limited during rollout despite financial support and mentorship. We illustrate that new

  10. Introduction of Syphilis Point-of-Care Tests, from Pilot Study to National Programme Implementation in Zambia: A Qualitative Study of Healthcare Workers' Perspectives on Testing, Training and Quality Assurance.

    Science.gov (United States)

    Ansbro, Éimhín M; Gill, Michelle M; Reynolds, Joanna; Shelley, Katharine D; Strasser, Susan; Sripipatana, Tabitha; Tshaka Ncube, Alexander; Tembo Mumba, Grace; Terris-Prestholt, Fern; Peeling, Rosanna W; Mabey, David

    2015-01-01

    Syphilis affects 1.4 million pregnant women globally each year. Maternal syphilis causes congenital syphilis in over half of affected pregnancies, leading to early foetal loss, pregnancy complications, stillbirth and neonatal death. Syphilis is under-diagnosed in pregnant women. Point-of-care rapid syphilis tests (RST) allow for same-day treatment and address logistical barriers to testing encountered with standard Rapid Plasma Reagin testing. Recent literature emphasises successful introduction of new health technologies requires healthcare worker (HCW) acceptance, effective training, quality monitoring and robust health systems. Following a successful pilot, the Zambian Ministry of Health (MoH) adopted RST into policy, integrating them into prevention of mother-to-child transmission of HIV clinics in four underserved Zambian districts. We compare HCW experiences, including challenges encountered in scaling up from a highly supported NGO-led pilot to a large-scale MoH-led national programme. Questionnaires were administered through structured interviews of 16 HCWs in two pilot districts and 24 HCWs in two different rollout districts. Supplementary data were gathered via stakeholder interviews, clinic registers and supervisory visits. Using a conceptual framework adapted from health technology literature, we explored RST acceptance and usability. Quantitative data were analysed using descriptive statistics. Key themes in qualitative data were explored using template analysis. Overall, HCWs accepted RST as learnable, suitable, effective tools to improve antenatal services, which were usable in diverse clinical settings. Changes in training, supervision and quality monitoring models between pilot and rollout may have influenced rollout HCW acceptance and compromised testing quality. While quality monitoring was integrated into national policy and training, implementation was limited during rollout despite financial support and mentorship. We illustrate that new

  11. A Cultural Resources Inventory and Historical Evaluation of the Smoky Atmospheric Nuclear Test, Areas 8, 9, and 10, Nevada National Security Site, Nye County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Robert C. [Desert Research Inst. (DRI), Reno, NV (United States); King, Maureen L. [Desert Research Inst. (DRI), Reno, NV (United States); Beck, Colleen M. [Desert Research Inst. (DRI), Reno, NV (United States); Falvey, Lauren W. [Desert Research Inst. (DRI), Reno, NV (United States); Menocal, Tatianna M. [Desert Research Inst. (DRI), Reno, NV (United States)

    2014-09-01

    This report presents the results of a National Historic Preservation Act Section 106 cultural resources inventory and historical evaluation of the 1957 Smoky atmospheric test location on the Nevada National Security Site (NNSS). The Desert Research Institute (DRI) was tasked to conduct a cultural resources study of the Smoky test area as a result of a proposed undertaking by the Department of Energy Environmental Management. This undertaking involves investigating Corrective Action Unit (CAU) 550 for potential contaminants of concern as delineated in a Corrective Action Investigation Plan. CAU 550 is an area that spatially overlaps portions of the Smoky test location. Smoky, T-2c, was a 44 kt atmospheric nuclear test detonated at 5:30 am on August 31, 1957, on top of a 213.4 m (700 ft) 200 ton tower (T-2c) in Area 8 of the NNSS. Smoky was a weapons related test of the Plumbbob series (number 19) and part of the Department of Defense Exercise Desert Rock VII and VIII. The cultural resources effort involved the development of a historic context based on archival documents and engineering records, the inventory of the cultural resources in the Smoky test area and an associated military trench location in Areas 9 and 10, and an evaluation of the National Register eligibility of the cultural resources. The inventory of the Smoky test area resulted in the identification of structures, features, and artifacts related to the physical development of the test location and the post-test remains. The Smoky test area was designated historic district D104 and coincides with a historic archaeological site recorded as 26NY14794 and the military trenches designed for troop observation, site 26NY14795. Sites 26NY14794 and 26NY14795 are spatially discrete with the trenches located 4.3 km (2.7 mi) southeast of the Smoky ground zero. As a result, historic district D104 is discontiguous and in total it covers 151.4 hectares (374 acres). The Smoky test location, recorded as historic

  12. Empirical investigation of wind farm blockage effects in Horn Rev 1 offshore wind farm

    DEFF Research Database (Denmark)

    Mitraszewski, Karol; Hansen, Kurt Schaldemose; Nygaard, Nicolai

    We present an empirical study of wind farm blockage effects based on Horns Rev 1 SCADA data. The mean inflow non-uniformities in wind speed are analyzed by calculating the mean power outputs of turbines located along the outer edges of the farm for different wind directions, wind speeds and stabi......We present an empirical study of wind farm blockage effects based on Horns Rev 1 SCADA data. The mean inflow non-uniformities in wind speed are analyzed by calculating the mean power outputs of turbines located along the outer edges of the farm for different wind directions, wind speeds...

  13. Anholt offshore wind farm winds investigated from satellite images

    DEFF Research Database (Denmark)

    Hasager, Charlotte Bay; Badger, Merete; Volker, Patrick

    , i.e. before the wind farm was constructed. Based on these data the wind resource is estimated. Concurrent Sentinel-1 SAR data and available SCADA and lidar data, kindly provided by DONG Energy and partners, for the period January 2013 to June 2015 account for ~70 images, while ~300 images...... are available for Sentinel-1 from July 2015 to February 2017. The Sentinel-1 wind maps are investigated for wind farm wake effects. Furthermore the results on wind resources and wakes are compared to the SCADA and model results from WRF, Park, Fuga and RANS models....

  14. Real time Intelligent Control Laboratory (RT-ICL) of PowerLabDK for smart grid technology development

    DEFF Research Database (Denmark)

    Ostergaard, Jacob; Wu, Qiuwei; Garcia-Valle, Rodrigo

    2012-01-01

    This paper presents the Intelligent Control Laboratory (ICL) of the PowerLabDK and describes examples of ongoing research work utilizing the ICL. The ICL is comprised of a real time digital simulator (RTDS) with 5 racks, a full scale SCADA system and experimental control room with a link to the B......This paper presents the Intelligent Control Laboratory (ICL) of the PowerLabDK and describes examples of ongoing research work utilizing the ICL. The ICL is comprised of a real time digital simulator (RTDS) with 5 racks, a full scale SCADA system and experimental control room with a link...

  15. Testing the generalizability of national reimbursement rates with respect to local setting: the costs of abdominal aortic aneurysm surgery in Denmark

    Directory of Open Access Journals (Sweden)

    Søren Løvstad Christensen

    2010-09-01

    Full Text Available Søren Løvstad Christensen1, Mette Kjoelby1,2, Lars Ehlers31Health Technology Assessment and Health Services Research, Centre for Public Health, Central Denmark Region, Denmark; 2School of Public Health, Aarhus University, Denmark; 3Health Economics and Management, Aalborg University, DenmarkObjective: The purpose of this study is to investigate if the Danish national diagnosis-related group (DRG tariffs for surgery for abdominal aortic aneurysm (AAA were good estimates of the actual costs in two local hospitals in the Central Region of Denmark.Methods: We collected clinical data for 178 AAA patients operated at Skejby Hospital and Viborg Hospital in the period 2005–2006 from the Danish National Vascular Registry and economic data from the administrative systems in the hospitals. We used bootstrap methods to calculate 95% confidence intervals (CIs for the mean costs of surgery for ruptured AAA, nonruptured AAA and AAA where the patient died within 30 days by applying a cost-trimming rule that the Danish National Board of Health uses in calculating national DRG tariffs.Results: The national DRG tariff lies within the calculated Danish Krone (DKK CIs (CI ruptured AAA, 98,178–195,327 [€13,196–€26,254]; CI nonruptured AAA, 79,039–98,178 [€10,624–€13,196]; CI dead, 42,023–111,685 [€5,648–€15,011], and thus national DRG tariffs could be a good estimate for the actual costs in the local hospitals.Conclusion: The bootstrap method is useful for testing the generalizability of national DRG tariffs as estimates of local surgical costs.Keywords: bootstrap method, costs, DRG, abdominal aortic aneurysm

  16. A Comparison of Student Test Results: Business and Marketing Education National Board Certified Teachers and Non-National Board Certified Teachers

    Science.gov (United States)

    Rouse, William Jr.; Hollomon, Harold L., Jr.

    2005-01-01

    The underlying question for the educational community is to determine the effect of the National Board for Professional Teaching Standards on creating a higher quality professional who, in turn, imparts knowledge so that their students are better educated to compete in a global economy. Thus, does the attainment of National Board Certification by…

  17. Production-scale LLW and RMW solidification system operational testing at Argonne National Laboratory-East (ANL-E)

    International Nuclear Information System (INIS)

    Wescott, J.; Wagh, A.; Singh, D.; Nelson, R.; No, H.

    1997-01-01

    Argonne National Laboratory-East (ANL-E) has begun production-scale testing of a low-level waste and radioactive mixed waste solidification system. This system will be used to treat low-level and mixed radioactive waste to meet land burial requirements. The system can use any of several types of solidification media, including a chemically bonded phosphate ceramic developed by ANL-E scientists. The final waste product will consist of a solidified mass in a standard 208-liter drum. The system uses commercial equipment and incorporates several unique process control features to ensure proper treatment. This paper will discuss the waste types requiring treatment, the system configuration, and operation results for these waste streams

  18. Australian national networked tele-test facility for integrated systems

    Science.gov (United States)

    Eshraghian, Kamran; Lachowicz, Stefan W.; Eshraghian, Sholeh

    2001-11-01

    The Australian Commonwealth government recently announced a grant of 4.75 million as part of a 13.5 million program to establish a world class networked IC tele-test facility in Australia. The facility will be based on a state-of-the-art semiconductor tester located at Edith Cowan University in Perth that will operate as a virtual centre spanning Australia. Satellite nodes will be located at the University of Western Australia, Griffith University, Macquarie University, Victoria University and the University of Adelaide. The facility will provide vital equipment to take Australia to the frontier of critically important and expanding fields in microelectronics research and development. The tele-test network will provide state of the art environment for the electronics and microelectronics research and the industry community around Australia to test and prototype Very Large Scale Integrated (VLSI) circuits and other System On a Chip (SOC) devices, prior to moving to the manufacturing stage. Such testing is absolutely essential to ensure that the device performs to specification. This paper presents the current context in which the testing facility is being established, the methodologies behind the integration of design and test strategies and the target shape of the tele-testing Facility.

  19. Tonopah Test Range - Index

    Science.gov (United States)

    Capabilities Test Operations Center Test Director Range Control Track Control Communications Tracking Radars Photos Header Facebook Twitter YouTube Flickr RSS Tonopah Test Range Top TTR_TOC Tonopah is the testing range of choice for all national security missions. Tonopah Test Range (TTR) provides research and

  20. Analysis of instantaneous profile test data from soils near the Mixed Waste Landfill, Technical Area 3, Sandia National Laboratories/New Mexico

    International Nuclear Information System (INIS)

    Goering, T.J.; McVey, M.D.; Strong, W.R.; Peace, J.L.

    1996-02-01

    This paper presents the results of an instantaneous profile test conducted near the Mixed Waste Landfill at Sandia National Laboratories/New Mexico. The purpose of the test was to measure the unsaturated hydraulic properties of soils near the Mixed Waste Landfill, including the relations between hydraulic conductivity, moisture content, and soil water tension. A 4.7 meter by 4.7 meter plot was saturated with water to a depth of 2 meters, and the wetting and drying responses of the vertical profile were observed. These data were analyzed to obtain in situ measurements of the unsaturated hydraulic properties