WorldWideScience

Sample records for national medical cyclotron

  1. National Medical Cyclotron

    International Nuclear Information System (INIS)

    Boyd, Rex.

    1991-01-01

    The National Medical Cyclotron, under construction at Sydney's Royal Prince Alfred Hospital(RPAH) is to be operated by the Australian Nuclear Science and Technology Organization in collaboration with the hospital. Its main purpose is to produce radioisotopes on commercial basis for distribution to hospitals through Australia as well as short-lived radioisotopes (2 minutes to 2 hours) for immediate application at RPAH in Positron Emission Tomography, to study the dynamics of human physiology and metabolism in organs, bones and soft tissues. A list of the principal cyclotron-produced radionuclides is provided. ills

  2. A national medical cyclotron facility: report to the Minister of Health by the Medical Cyclotron Committee

    International Nuclear Information System (INIS)

    1985-01-01

    Research and training in nuclear medicine in Australia are both limited by the lack of a medical cyclotron facility. The Committee recommends the establishment of a national medical cyclotron to provide a supply of short-lived radioisotopes for research in relevant fields of medicine, and for diagnostic use in nuclear medicine

  3. Medical Cyclotrons

    Science.gov (United States)

    Friesel, D. L.; Antaya, T. A.

    Particle accelerators were initially developed to address specific scientific research goals, yet they were used for practical applications, particularly medical applications, within a few years of their invention. The cyclotron's potential for producing beams for cancer therapy and medical radioisotope production was realized with the early Lawrence cyclotrons and has continued with their more technically advanced successors — synchrocyclotrons, sector-focused cyclotrons and superconducting cyclotrons. While a variety of other accelerator technologies were developed to achieve today's high energy particles, this article will chronicle the development of one type of accelerator — the cyclotron, and its medical applications. These medical and industrial applications eventually led to the commercial manufacture of both small and large cyclotrons and facilities specifically designed for applications other than scientific research.

  4. The National Medical Cyclotron - An Australian experience in technology

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, R K [Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW (Australia). National Medical Cyclotron

    1998-12-31

    The establishment of the National Medical Cyclotron (NMC) in the early 1990`s was the practical outcome of a vision, held by nuclear medicine professionals, to complement the available neutron-rich radionuclides produced in Australia, with neutron-deficient radionuclides. The NMC is operated by the Australian Nuclear Science and Technology Organisation (ANSTO) in collaboration with the Royal Prince Alfred Hospital (RPAH) in Sydney where the PET department is able to use the short-lived radiotracers to good advantage. Neutron-deficient radionuclides, are also produced by the NMC laboratories. The cyclotron-generated radionuclides are used in over 70,000 patient studies per year. 7 refs., 1 tab.

  5. The National Medical Cyclotron - An Australian experience in technology

    International Nuclear Information System (INIS)

    Barnes, R. K.

    1997-01-01

    The establishment of the National Medical Cyclotron (NMC) in the early 1990's was the practical outcome of a vision, held by nuclear medicine professionals, to complement the available neutron-rich radionuclides produced in Australia, with neutron-deficient radionuclides. The NMC is operated by the Australian Nuclear Science and Technology Organisation (ANSTO) in collaboration with the Royal Prince Alfred Hospital (RPAH) in Sydney where the PET department is able to use the short-lived radiotracers to good advantage. Neutron-deficient radionuclides, are also produced by the NMC laboratories. The cyclotron-generated radionuclides are used in over 70,000 patient studies per year

  6. New irradiation facilities at the Australian national medical cyclotron

    International Nuclear Information System (INIS)

    Parcell, S.K.; Arnott, D.W.; Conard, E.M.

    1999-01-01

    Two new irradiation facilities have been developed at the National Medical Cyclotron for radionuclide production. The first relocates PET irradiations from the cyclotron vault to a dedicated PET beam room, to improve accessibility and reduce radiation exposures associated with target maintenance. This new facility consists of a beam line to transport 16-30 MeV proton beams from the cyclotron to 1 of 8 PET targets mounted on a target rack. The target rack has increased the number of targets available for production and experimentation. The second is a completely independent solid target irradiation facility for SPECT. This facility consists of a beam line to transport 26-30 MeV proton beams from the cyclotron to a dedicated beam room containing one solid target station. A new pneumatic target transfer system was also developed to transport the solid target to and from the existing chemistry hot cells. The beam line and target components are operated under the control of a dedicated PLC with a PC based user interface. The development and some technical aspects of these new irradiation facilities are discussed here. (author)

  7. Operational experience and recent developments at the National Medical Cyclotron

    International Nuclear Information System (INIS)

    Conard, E.; Pac, B.; Arnott, D.W.

    1994-01-01

    The National Medical Cyclotron is a radioisotope production facility run by ANSTO and located on the grounds of the Royal Prince Alfred Hospital in Sydney, Australia. A CYCLONE 30 (IBA) cyclotron is used in the production of short-lived PET radiopharmaceuticals required by the hospital's PET Scanner and also to produce a number of bulk radiochemicals for processing and distribution throughout Australasia. Following commissioning of the cyclotron and beam lines in October 1991, and the overcoming of a number of early open-quote teething close-quote problems especially relating to the reliability of the r.f. and solid target transport systems, a steady program of improvements has been pursued. These improvements have included development of new beam diagnostics and the design and installation of a new beam line for SPECT radioisotope production. The current operations schedule includes the production of 18 FDG, 13 NH 3 , 15 O 2 and 201 Tl, 67 Ga and 123 I. This paper will discuss the process of development of the cyclotron to ably meet the present demands on it, and the problems resolved in the pursuit of this goal

  8. Operational health and physics service during the maintenance of the Australian National Medical Cyclotron

    International Nuclear Information System (INIS)

    Mukherjee, B.

    1994-01-01

    Modern Medical Cyclotrons use intense beams of high energy protons or deuterons to produce large activities of short and medium lived radionuclides. After continuous operation for prolonged periods the Cyclotron components become activated through various nuclear interactions therefore, the risk of personal radiation hazard while handling such activated cyclotron components is high. This paper describes all operational aspects of the Health Physics service evolved during the first preventative maintenance program of the Australian National Medical Cyclotron, which took place in June 1993. 5 refs., 3 tabs., 2 figs

  9. Operational experience and recent developments at the National Medical Cyclotron, Sydney

    International Nuclear Information System (INIS)

    Conard, E.M.; Arnott, D.W.

    1996-01-01

    The National Medical Cyclotron, Sydney, Australia commenced operation in mid 1991, with a mission to provide PET and SPECT radionuclides throughout Australia. The realization of the present production capacity has been synonymous with the development of the facility's industrial cyclotron (IBA Cyclone 30). The choice of cyclotron was based on the Cyclone 30's virtues as a compact, user-friendly, energy efficient cyclotron, offering the beam quality characteristic of negative ion technology. Development of the cyclotron has improved reliability and increased beam capacity, while improvements to targetry have increased production reliability. More recently, the installation and commissioning of a new solid target irradiation facility has provided much needed redundancy. This paper describes the major cyclotron and targetry developments carried out to date. (orig.)

  10. Medical cyclotrons

    International Nuclear Information System (INIS)

    Wolf, A.P.

    1976-01-01

    Cyclotrons as tools for therapy and for the production of radionuclides for use in nuclear medicine have been extensively reviewed in the literature. The current world status with respect to cyclotrons used primarily for research, development and application in nuclear medicine is reviewed here in the context of geographical distribution and type of use, presently available commercial types, machine characteristics and trends. Aspects of design requirements from a user perspective such as machine, beam and target characteristics are covered. Some special problems concerning many factors which can lead to effective production of the desired radionuclide or product are considered in light of machine characteristics. Consideration is also given to future directions for accelerators in nuclear medicine

  11. Medical cyclotron facilities

    International Nuclear Information System (INIS)

    1984-09-01

    This report examines the separate proposals from the Austin Hospital and the Australian Atomic Energy Commission for a medical cyclotron facility. The proponents have argued that a cyclotron facility would benefit Australia in areas of patient care, availability and export of radioisotopes, and medical research. Positron emission tomography (PET) and neutron beam therapy are also examined

  12. Medical applications of cyclotrons

    International Nuclear Information System (INIS)

    Jean, R.; Fauchet, M.

    1978-01-01

    Isochronous cyclotrons used to accelerate different charged particles (protons, deuterons, alphas...) at variable energies, have important medical applications, for neutron teletherapy, in vivo or in vitro activation analysis or production of short-lived radioisotopes for nuclear medicine. The characteristics of the cyclotron presently available are described for these three applications (low energy 'compact' cyclotrons, cyclotrons of intermediate and high energies), and their advantages are discussed from the points of view of the medical requirements, the financial investments and the results obtained. (orig.) [de

  13. Medical cyclotron: why, where, how

    International Nuclear Information System (INIS)

    Scheer, Kurt; Comar, Dominique; Kellershohn, Claude

    1976-01-01

    Cyclotrons for medical purposes are particularly useful for the production of radioactive isotopes of elements normally constituting organic matter ( 15 O, 13 N, 11 C). The short half-life and positron emission of those elements are of great interest in medical diagnosis. Many others carrier-free radioisotopes can be produced by cyclotrons. Three categories of cyclotrons are mentioned. Desk top cyclotron only adapted to the production of short-lived radioisotopes in a hospital; low energy and average energy cyclotrons which require well-entrained personnel for their operation and are best adapted to the production of radioelements on a regional or even national scale. Examples relative to the interest of short-lived radioisotopes in lung and brain investigations and tumor detection are given

  14. Developing the smallest possible medical cyclotron

    CERN Multimedia

    Katarina Anthony

    2011-01-01

    Imagine a portable medical cyclotron operated in a conventional radioactive facility at a hospital. Imagine a nurse or technician switching it on and producing isotopes at the patient’s bedside. Sounds like science fiction? Think again.   CERN has teamed up with Spain’s national scientific research centre (CIEMAT) to develop an avant-garde cyclotron to be used for Positron Emission Tomography (PET). “We plan to make a cyclotron that doesn't need an insulated building or ‘vault’: a cyclotron small enough to fit inside a hospital lift,” explains Jose Manuel Perez, who is leading the CIEMAT/CERN collaboration. “It will be the smallest possible medical cyclotron for single patient dose production and will dramatically reduce costs for hospitals.” While PET technology has transformed imaging techniques, many of its medical benefits have remained confined to highly specialised hospitals. “Studies have foun...

  15. Atmospheric tracer tests and assessment of a potential accident at the National Medical Cyclotron, Camperdown, NSW, Australia

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G H; Bartsch, F J.K.; Stone, D J.M.

    1994-08-01

    In order to assess the impact of a potential atmospheric release of radionuclides from the National Medical Cyclotron facility, in Camperdown, an atmospheric tracer release, sampling and analysis system using SF{sub 6} was developed. During eight experiments conducted in a variety of meteorological conditions, ten samplers were located in the vicinity of the Cyclotron building and other nearby buildings on the rapid downward movement of the tracer gas plume. The atmospheric dilution factors which lead to the highest observed air concentrations were then applied to the releases of I{sup 123} and Xe{sup 123} from a potential accident scenario in order to assess the impact on nearby receptors. Even given the conservative assumptions about the release of I{sup 123}, the estimated radiation doses were at least an order of magnitude below the international standards for doses to member of the public. 27 refs., 8 tabs., 5 figs.

  16. Atmospheric tracer tests and assessment of a potential accident at the National Medical Cyclotron, Camperdown, NSW, Australia

    International Nuclear Information System (INIS)

    Clark, G.H.; Bartsch, F.J.K.; Stone, D.J.M.

    1994-08-01

    In order to assess the impact of a potential atmospheric release of radionuclides from the National Medical Cyclotron facility, in Camperdown, an atmospheric tracer release, sampling and analysis system using SF 6 was developed. During eight experiments conducted in a variety of meteorological conditions, ten samplers were located in the vicinity of the Cyclotron building and other nearby buildings on the rapid downward movement of the tracer gas plume. The atmospheric dilution factors which lead to the highest observed air concentrations were then applied to the releases of I 123 and Xe 123 from a potential accident scenario in order to assess the impact on nearby receptors. Even given the conservative assumptions about the release of I 123 , the estimated radiation doses were at least an order of magnitude below the international standards for doses to member of the public. 27 refs., 8 tabs., 5 figs

  17. General aspects of meteorology and wind flow patterns at the National Medical Cyclotron site, Camperdown, NSW, Australia

    International Nuclear Information System (INIS)

    Clark, G.H.; Bartsch, F.J.K.

    1994-06-01

    As part of an assessment into the consequences of a potential accident at the National Medical Cyclotron, Camperdown, NSW., Australia, two meteorological stations were installed to monitor the winds, temperatures and atmospheric dispersion conditions. The data will be used to assess environmental impacts of the Cyclotron's operation. In spite of the relatively poor performance of the stations, the wind data indicated significant effects of local buildings and the general urban surface roughness features. The prevailing winds during the study were from the north-north-west at night and south-south-west or north-east sea breezes during the day. Atmospheric stability/dispersion categories were typical of an urban heat island location. 11 refs., 10 tabs, 6 figs

  18. Development of Medical Cyclotron in KIRAMS

    International Nuclear Information System (INIS)

    Chai, Jong Seo; Jung, In Su; An, Dong Hyun

    2005-01-01

    This paper is presented on the development and status of medical cyclotron at the Korea Institute of Radiological and Medical Sciences (KIRAMS) at present. We have developed medical cyclotron which is KIRAMS-13. And the improvement of KIRAMS-13 is presented. Furthermore, the design of new cyclotrons, such as KIRAMS-5 and KIRAMS-30 cyclotron, are presented, and R and D studies for future plan of heavy ion accelerator are discussed

  19. Medical cyclotron basic concepts and its applications

    International Nuclear Information System (INIS)

    Kumar, Rajeev; Sonkawade, R.G.

    2012-01-01

    More than 3000 nuclides are known, of which approximately 2700 are radioactive, and rest are stable. The majority of radionuclides are artificially produced in the reactor and cyclotron. In a cyclotron, Charge particle such as proton, Deuteron, á (Alpha) particle, 3 He particles and so forth are accelerated in circular paths within the Dees under vacuum by means of an electromagnetic field. These accelerated particles can possess few KeV to several BeV of kinetic energy depending on the design of the cyclotron. At our setup we have an 11 MeV dual beam multi target cyclotron which is capable producing 11 C, 13 N, 15 O, 18 F and 2 F radioisotopes and all have been successfully produced and tested in our lab. Earlier cyclotrons were the best source of high-energy beams for nuclear physics experiments; several cyclotrons are still in use for this type of research. Cyclotrons can be used to treat cancer. Ion beams from cyclotrons can be used, as in proton therapy. The positron emitting isotopes are suitable for PET imaging. As discussed we are producing mainly Carbon-11, Nitrogen-13, Oxygen-15, and Fluorine-18: These are positron emitters used in PET for studying brain physiology and pathology, in particular for localizing epileptic focus, and in dementia, psychiatry and neuropharmacology studies. So these are having significant role in diagnosis of Oncological, Neurological and Cardiological disorder. More than ninety percent we are producing 18 F in FDG. 18 F in FDG (Flouro-Deoxy-glucose) has become very important in detection of cancers and the monitoring of progress in their treatment, using PET. Medical cyclotron is complex equipment requiring delicate handling by highly trained personnel. The aim of this article is to highlight few finer aspects of Medical cyclotron operation, including precautions for safety and smooth functioning of this sophisticated equipment. (author)

  20. Development of a Medical Cyclotron Production Facility

    Science.gov (United States)

    Allen, Danny R.

    2003-08-01

    Development of a Cyclotron manufacturing facility begins with a business plan. Geographics, the size and activity of the medical community, the growth potential of the modality being served, and other business connections are all considered. This business used the customer base established by NuTech, Inc., an independent centralized nuclear pharmacy founded by Danny Allen. With two pharmacies in operation in Tyler and College Station and a customer base of 47 hospitals and clinics the existing delivery system and pharmacist staff is used for the cyclotron facility. We then added cyclotron products to contracts with these customers to guarantee a supply. We partnered with a company in the process of developing PET imaging centers. We then built an independent imaging center attached to the cyclotron facility to allow for the use of short-lived isotopes.

  1. Development of a Medical Cyclotron Production Facility

    International Nuclear Information System (INIS)

    Allen, Danny R.

    2003-01-01

    Development of a Cyclotron manufacturing facility begins with a business plan. Geographics, the size and activity of the medical community, the growth potential of the modality being served, and other business connections are all considered. This business used the customer base established by NuTech, Inc., an independent centralized nuclear pharmacy founded by Danny Allen. With two pharmacies in operation in Tyler and College Station and a customer base of 47 hospitals and clinics the existing delivery system and pharmacist staff is used for the cyclotron facility. We then added cyclotron products to contracts with these customers to guarantee a supply. We partnered with a company in the process of developing PET imaging centers. We then built an independent imaging center attached to the cyclotron facility to allow for the use of short-lived isotopes

  2. Emergency situation in a medical cyclotron facility

    International Nuclear Information System (INIS)

    Kumar, Rajeev; Bhat, M.K.; Singh, D.K.; Pthania, B.S.; Pandit, A.G.; Jacob, M.J.

    2010-01-01

    Full text: Medical cyclotron is a particle accelerator used in producing short lived radioisotopes such as 18 F, 11 C, 15 O, 13 N, 18 F-2 gas etc. Positron Emission Tomography (PET) is a nuclear imaging modality that has rapidly gained favour. 18 F-FDG is the most widely used radiopharmaceutical with a half-life of 109.8 min. Having more than five years experience in this field we face lots of emergency conditions in the medical cyclotron facility. On the basis of harm we have divided in to three categories i.e. Harm of (a) working personnel, (b) Equipment and (c) environment. Radioactive gas leak and Target foil rupture is considered as the major emergency situations during medical cyclotron operations because there is a potential of over exposure to the working personnel. Radiation protection survey of a self-shielded medical cyclotron installation was carried out during normal and emergency conditions. It is found that the induced activity in the target foil increases with its successive usages. Recommendations have also been made to reduce personal exposure while handling the radioactive gas leak and target foil rupture conditions

  3. Radiation shielding and health physics instrumentation for PET medical cyclotrons

    International Nuclear Information System (INIS)

    Mukherjee, B.

    2002-01-01

    Full text: Modern Medical Cyclotrons produce a variety of short-lived positron emitting PET radioisotopes, and as a result are the source of intense neutron and gamma radiations. Since such cyclotrons are housed within hospitals or medical clinics, there is significant potential for un-intentional exposure to staff or patients in proximity to cyclotron facilities. Consequently, the radiological hazards associated with Cyclotrons provide the impetus for an effective radiological shielding and continuous monitoring of various radiation levels in the cyclotron environment. Management of radiological hazards is of paramount importance for the safe operation of a Medical Cyclotron facility. This work summarised the methods of shielding calculations for a compact hospital based Medical Cyclotron currently operating in Canada, USA and Australia. The design principle and operational history of a real-time health physics monitoring system (Watchdog) operating at a large multi-energy Medical Cyclotron is also highlighted

  4. Radioisotope production with a medical cyclotron

    International Nuclear Information System (INIS)

    Silvester, D.J.

    1974-01-01

    The cyclotron of Hammersmith hospital in England was completed and started the operation in 1955. The feature is in its design operable at high beam current, reaching 500μA in internal beam and 300μA in external beam. In 1960's, twelve nuclides of radioactive pharmaceuticals were produced with the cyclotron. C-11, N-13 and O-15 have been used in the form of radioactive gases such as CO or H 2 O to test lung functions. F-18 has been used for bone scanning. K-43 is employed in the research of electrolyte balancing together with Na-24 and Br-77. Fe-52 is utilized in iron ion researches as a tracer. Cs-129 is highly evaluated as an isotope for imaging cardiac clogging part. Radioisotopes must be much more used in the examination of in vivo metabolic function. For this purpose, peculiarly labelled compounds should be further developed. It is welcome that the persons paying attention to the medical prospect of cyclotrons are increasing. The author hopes to continue his endeavour to find new products made with the cyclotron for human welfare. (Wakatsuki, Y.)

  5. The Medical Cyclotron Facility in RMC, Parel, BARC

    International Nuclear Information System (INIS)

    Gopalakrishna, Arjun; Banerjee, Sharmila

    2017-01-01

    The Medical Cyclotron Facility in Radiation Medicine Centre (RMC) is the first one of its kind, installed in 2002. "1"8F based radiotracers are produced in this facility on a routine basis for Positron Emission Tomography (PET), of in-house patients, as well as for supply to other nuclear medicine centers in Mumbai as well as Pune. The facility consists of the following sub parts - Cyclotron and support equipment; Radiochemistry synthesis laboratory; Quality control (QC) laboratory

  6. New design for a medical cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, M

    1985-12-01

    The Oxford Instruments Group PLC, have designed a 30 MeV energy proton cyclotron incorporating a super-conducting magnet and a novel RF accelerating cavity. The energy range is suitable for the production of isotopes such as /sup 67/Ga, /sup 111/In, /sup 123/I and /sup 201/Tl, and the short lived isotopes of carbon, nitrogen, oxygen and fluorine for use in Positron Emmission Tomography (PET). A new magnet and RF cavity design permit a considerable power and weight reduction and a compact size (1.5m dia x 1.9m high), allowing the cyclotron to be transported to a shielded site as an assembly after factory testing. A method of beam extraction has been adopted which minimises activation of the accelerator components and so allows hands on maintenance to be carried out when required.

  7. Optimization approach for saddling cost of medical cyclotrons with fuzziness

    International Nuclear Information System (INIS)

    Abass, S.A.; Massoud, E.M.A.

    2007-01-01

    Most radiation fields are combinations of different kinds of radiation. The radiations of most significance are fast neutrons, thermal neutrons, primary gammas and secondary gammas. Thermos's composite shielding materials are designed to attenuate these types of radiation. The shielding design requires an accurate cost-benefit analysis based on uncertainty optimization technique. The theory of fuzzy sets has been employed to formulate and solve the problem of cost-benefit analysis of medical cyclotron. This medical radioisotope production cyclotron is based in Sydney, Australia

  8. Use of cyclotrons in medical research: Past, present, future

    Science.gov (United States)

    Smathers, James B.; Myers, Lee T.

    1985-05-01

    The use of cyclotrons in medical research started in the late 1930s with the most prominent use being neutron irradiation in cancer therapy. Due to a lack of understanding of the biological effect of neutrons, the results were less than encouraging. In the 1940s and 1950s, small cyclotrons were used for isotope production and in the mid 60s, the biological effect of neutrons was more thoroughly studied, with the result that a second trial of neutron therapy was initiated at Hammersmith Hospital, England. Concurrent with this, work on the use of high energy charged particles, initially protons and alphas, was initiated in Sweden and Russia and at Harvard and Berkeley. The English success in neutron therapy led to some pilot studies in the USA using physics cyclotrons of various energies and targets. These results in turn lead to the present series of machines presently being installed at M.D. Anderson Hospital (42 MeV), Seattle (50 MeV) and UCLA (46 MeV). The future probably bodes well for cyclotrons at the two extremes of the energy range. For nuclear medicine the shift is away from the use of multiple isotopes, which requires a large range of particles and energies to 11C, 13N, 15O, and 18F, which can be incorporated in metabolic specific compounds and be made with small 8-10 MeV p+ "table top" cyclotrons. For tumor therapy machines of 60 MeV or so will probably be the choice for the future, as they allow the treatment of deep seated tumors with neutrons and the charged particles have sufficient range to allow the treatment of ocular tumors.

  9. A real-time positron monitor for the estimation of stack effluent releases from PET medical cyclotron facilities

    International Nuclear Information System (INIS)

    Mukherjee, Bhaskar.

    2002-01-01

    Large activities of short-lived positron emitting radiopharmaceuticals are routinely manufactured by modern Medical Cyclotron facilities for positron emission tomography (PET) applications. During radiochemical processing, a substantial fraction of the volatile positron emitting radiopharmaceuticals are released into the atmosphere. An inexpensive, fast response positron detector using a simple positron-annihilation chamber has been developed for real-time assessment of the stack release of positron emitting effluents at the Australian National Medical Cyclotron. The positron detector was calibrated by using a 3.0 ml (1.50 MBq) aliquot of 18 FDG and interfaced to an industrial standard datalogger for the real-time acquisition of stack release data

  10. THE ROLE OF THE CYCLOTRON IN MEDICAL RESEARCH

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, Joseph G.

    1950-04-19

    The uses of radioactive isotopes in medical research can be conveniently divided into three principal categories; namely, the applications as tracers for the study of metabolic phenomena, as diagnostic aids in clinical medicine, and finally their role in therapy. Frequently radioisotopes available from the chain-reacting pile do not have a sufficient degree of specific activity for satisfactory use. A number of radioisotopes which can be produced with high specific activity in the pile possess half-lives too short to be of any practical value. Then, there are a few cases in which the desired radioisotope may be made in the pile with high specific activity, but concomitantly there is formed another radioisotope of the same element whose half-life is of such duration as to render its use hazardous in man. Finally, there are several elements of biological and medical interest whose radioactive isotopes can be produced only by the cyclotron.

  11. Review of Cyclotrons for the Production of Radioactive Isotopes for Medical and Industrial Applications

    Science.gov (United States)

    Schmor, Paul

    2011-02-01

    Radioactive isotopes are used in a wide range of medical, biological, environmental and industrial applications. Cyclotrons are the primary tool for producing the shorter-lived, proton-rich radioisotopes currently used in a variety of medical applications. Although the primary use of the cyclotron-produced short-lived radioisotopes is in PET/CT (positron emission tomography/computed tomography) and SPECT (single photon emission computed tomography) diagnostic medical procedures, cyclotrons are also producing longer-lived isotopes for therapeutic procedures as well as for other industrial and applied science applications. Commercial suppliers of cyclotrons are responding by providing a range of cyclotrons in the energy range of 3-70MeV for the differing needs of the various applications. These cyclotrons generally have multiple beams servicing multiple targets. This review article presents some of the applications of the radioisotopes and provides a comparison of some of the capabilities of the various current cyclotrons. The use of nuclear medicine and the number of cyclotrons supplying the needed isotopes are increasing. It is expected that there will soon be a new generation of small "tabletop" cyclotrons providing patient doses on demand.

  12. A new generation of medical cyclotrons for the 90's

    International Nuclear Information System (INIS)

    Milton, B.F.

    1995-08-01

    Cyclotrons continue to be efficient accelerators for use in radio-isotope production. In recent years, developments in accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicates a strong future for commercial cyclotrons. In this paper the authors will survey recent developments in the areas of cyclotron technology as they relate to the new generation of commercial cyclotrons. Existing and potential markets for these cyclotrons will be presented. They will also discuss the possibility of systems capable of extracted energies up to 150 MeV and extracted beam currents of up to 2.0 mA

  13. A new generation of medical cyclotrons for the 90's

    International Nuclear Information System (INIS)

    Milton, B.F.

    1995-08-01

    Cyclotrons continue to be efficient accelerators for use in radio-isotope production. In recent years, developments in accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicates a strong future for commercial cyclotrons. In this paper we will survey recent developments in the areas of cyclotron technology as they relate to the new generation of commercial cyclotrons. Existing and potential markets for these cyclotrons will be presented. We will also discuss the possibility of systems capable of extracted energies up to 150 MeV and extracted beam currents of up to 2.0 mA. (author)

  14. Research and investigation on medical usage of cyclotrons as a special research project

    International Nuclear Information System (INIS)

    1980-01-01

    In the National Institute of Radiological Sciences, the special research project ''Research and investigation on the medical usage of cyclotrons'' had been carried out in the three years program from fiscal 1976 to 1978. Its purpose was to establish the methods of therapy using particle beam such as fast neutrons and the methods of diagnosis using short-lived radioisotopes and positron-emitting radioisotopes. The works were conducted comprehensively in cooperation of the personnel both in and outside the NIRS. Consequently, the purpose was able to be fulfilled satisfactorily. Following on this project, a new special research project ''Research and investigation on the medical usage of particle accelerators'' was started in fiscal 1979. These results are described on the effects of the therapy, diagnostic utilizations, and the medical usage of heavy ion accelerators. (J.P.N.)

  15. Ion source and injection line for high intensity medical cyclotron

    Science.gov (United States)

    Jia, XianLu; Guan, Fengping; Yao, Hongjuan; Zhang, TianJue; Yang, Jianjun; Song, Guofang; Ge, Tao; Qin, Jiuchang

    2014-02-01

    A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H- ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H- ion source (CIAE-CH-I type) and a short injection line, which the H- ion source of 3 mA/25 keV H- beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from the extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.

  16. Radiation safety and operational health physics of hospital based medical cyclotrons

    International Nuclear Information System (INIS)

    Mukherjee, B.

    2002-01-01

    Full text: Compact, low energy, high current Medical Cyclotrons are now primarily used to produce large activities of short lived, neutron deficient, positron- emitting radioisotopes. These isotopes constitute the key ingredients of important PET (Positron Emission Tomography) radiopharmaceuticals used in diagnostic nuclear medicine. The PET-radioisotope producing Medical Cyclotrons are now increasingly installed in modern urban hospitals in many countries of the world. Modern Medical Cyclotrons run at a very high beam current (∼100-200 micro Amp) level and thereby produce intense fields of parasitic gamma rays and neutrons, causing the activation of cyclotron components, ambient air and radiation exposure to patients and members of the public. This report highlights the important operational aspects and the characteristics of the radiation fields produced by Medical Cyclotrons. The pathways of personnel radiation exposure are also analyzed. The above information constitutes the scientific basis of a sound operational health physics service, which is manifested in an effective dose reduction and an enhanced radiological safety of the Medical Cyclotron facility within the framework of ALARA

  17. Status report on electron cyclotron resonance ion sources at the Heavy Ion Medical Accelerator in Chiba

    CERN Document Server

    Kitagawa, A; Sekiguchi, M; Yamada, S; Jincho, K; Okada, T; Yamamoto, M; Hattori, T G; Biri, S; Baskaran, R; Sakata, T; Sawada, K; Uno, K

    2000-01-01

    The Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences (NIRS) is not only dedicated to cancer therapy, it is also utilized with various ion species for basic experiments of biomedical science, physics, chemistry, etc. Two electron cyclotron resonance (ECR) ion sources are installed for production of gaseous ions. One of them, the NIRS-ECR, is a 10 GHz ECR ion source, and is mainly operated to produce C/sup 4+/ ions for daily clinical treatment. This source realizes good reproducibility and reliability and it is easily operated. The other source, the NIRS-HEC, is an 18 GHz ECR ion source that is expected to produce heavier ion species. The output ion currents of the NIRS-ECR and the NIRS-HEC are 430e mu A for C/sup 4+/ and 1.1e mA for Ar/sup 8+/, respectively. (14 refs).

  18. Regulatory Compliance to Assure the Safety of the Operation of a Medical Cyclotron

    International Nuclear Information System (INIS)

    Dela Cruz, Joselito

    2015-01-01

    Khealth Corporation, in Partnership with the National Kidney and Transplant Institute, has established a medical cyclotron facility to accommodate the up-and-coming needs of tracers for PET/CT in different centers and hospitals all over the country. This facility houses a 16.5 MeV GE PET trace 880 particle accelerator that can produce 14 Ci (518 GBq) of Fluorine-18. Its structure has adopted global standard designs in meeting the safety during its use, radiopharmaceutical production and distribution. Compliances were remarkably fulfilled from the building construction, machine acquisition, commissioning, operations up to the quality control and assurance. Furthermore, various regulatory challenges during the current standardization of radiopharmaceutical utilization were encountered however time dedication and efforts were wielded until all have been successfully justified and acquired. (author)

  19. Decontamination of the activation product based on a legal revision of the cyclotron vault room on the non-self-shield compact medical cyclotron

    International Nuclear Information System (INIS)

    Komiya, Isao; Umezu, Yoshiyuki; Fujibuchi, Toshiou; Nakamura, Kazumasa; Baba, Shingo; Honda, Hiroshi

    2016-01-01

    The non-self-shield compact medical cyclotron and the cyclotron vault room were in operation for 27 years. They have now been decommissioned. We efficiently implemented a technique to identify an activation product in the cyclotron vault room. Firstly, the distribution of radioactive concentrations in the concrete of the cyclotron vault room was estimated by calculation from the record of the cyclotron operation. Secondly, the comparison of calculated results with an actual measurement was performed using a NaI scintillation survey meter and a high-purity germanium detector. The calculated values were overestimated as compared to the values measured using the Nal scintillation survey meter and the high-purity germanium detector. However, it could limit the decontamination area. By simulating the activation range, we were able to minimize the concrete core sampling. Finally, the appropriate range of radioactivated area in the cyclotron vault room was decontaminated based on the results of the calculation. After decontamination, the radioactive concentration was below the detection limit value in all areas inside the cyclotron vault room. By these procedures, the decommissioning process of the cyclotron vault room was more efficiently performed. (author)

  20. Optimisation of the radiation shielding of medical cyclotrons using a genetic algorithm

    International Nuclear Information System (INIS)

    Mukherjee, Bhaskar

    2000-01-01

    Effective radiation shielding is imperative for safe operation of modern Medical Cyclotrons producing large activities of short-lived radioisotopes on a commercial basis. The optimal cyclotron shielding design demands a careful balance between the radiological, economical and often the sociopolitical factors. One is required to optimize the cost of radiation protection and the cost of radiological-health detriment. The cost of radiation protection depends explicitly on a) the nature of the radiation field produced by the cyclotron, b) the cyclotron operation condition, c) the cost of shielding material, d) the level of dose reduction, e) the projected net revenue from the sale of the radioisotopes, and f) the depreciation rate of the cyclotron facility. The Genetic Algorithm (GA) is used for a cost -benefit analysis of this problem. The GA is a mathematical technique that emulates the Darwinian Evolution paradigm. It is ideally suited to search for a global optimum in a large multi-dimensional solution space, having demonstrated strength compared to the classical analytical methods. Furthermore the GA method runs on a PC in a Windows environment. This paper highlights an interactive spreadsheet macro program for the cost benefit analysis of the optimize Medical Cyclotron shielding using a GA search engine. (author)

  1. Clinical diagnostic system using a small cyclotron for medical use

    International Nuclear Information System (INIS)

    Yonekura, Y.; Magata, Y.; Konishi, J.

    1990-01-01

    Since a small cyclotron and a positron emission tomography (PET) scanner have been installed at the Kyoto University Hospital in 1983, a great deal of effort has been directed to the clinical application of the PET-cyclotron system. This paper outlines the experience with PET in the clinical setting, including the facility, equipments and staff involved, weekly schedule, typical clinical protocols, and some results from the patients. The system consists of small cyclotron for production of the short-lived positron emitting radionuclides, fully automated synthesis system for labeling various compounds, scanning for measurement of radioactivities, and data analysis system for calculating physiological parameters. A resolving cylinder target system with eight smaller cylinders is equipped for production of C-11, N-13, O-15, and F-18. Labeled compounds are quickly delivered to the PET scanner room by two systems--the continuous delivery system for the labeled gas and the rapid delivery system for the liquid compounds by compressed air. A PET scanner devoted for clinical studies is a multislice whole-body PET scanner. Ten PET studies are performed weekly on the average for measuring blood flow and oxygen and glucose metabolism in the brain, blood flow and glucose and fatty acid metabolism in the heart, blood flow and amino acid uptake in the pancreas, lung ventilation, and tumor glucose metabolism. The availability of PET-cyclotron system is still limited in view of cost. The previous clinical studies suggest the contribution of PET to the the understanding of the mechanism of disease pathophysiology. (N.K.)

  2. Radiation shielding analysis of medical cyclotron at Radiation Medicine Centre, Parel

    International Nuclear Information System (INIS)

    Gathibandhe, M.V.; Agrawal, R.A.; Utge, C.G.

    2003-01-01

    Full text: PET (Positron Emission Tomography) is a diagnostic method to obtain 3-D functional images of the distribution of radio-nuclides introduced in the human body as tracers for specific biological processes. Tracers are produced by bombardment of different target nuclides by protons and deuterons of high energy produced in the cyclotron. A Wipro-GE medical cyclotron was installed in the basement of RMC, Parel. Shielding around the cyclotron is provided in the form of borated concrete walls of required thickness to limit dose rates to design values as per AERB criteria. The roof of the cyclotron room is made of heavy concrete. Entry in to the room is through a maze. Shielding analysis for the cyclotron room has been carried out using computer code ANISN. The maze has been analyzed using code MCNP. Based on the analysis carried out additional shielding was recommended to meet the design requirements. The paper discusses the shielding analysis carried out for the cyclotron room and the maze. Dose rate estimated at various locations are highlighted

  3. Cost benefit analysis of the radiological shielding of medical cyclotrons using a genetic algorithm

    International Nuclear Information System (INIS)

    Mukherjee, Bhaskar

    2001-01-01

    Adequate radiation shielding is vital to the safe operation of modern commercial medical cyclotrons producing large yields of short-lived radioisotopes. The radiological shielding constitutes a significant capital investment for any new cyclotron-based radioisotope production facility; hence, the shielding design requires an accurate cost-benefit analysis often based on a complex multi-variant optimization technique. This paper demonstrates the application of a Genetic Algorithm (GA) for the optimum design of the high yield target cave of a Medical Cyclotron radioisotope production facility based in Sydney, Australia. The GA is a novel optimization technique that mimics the Darwinian Evolution paradigm and is ideally suited to search for global optima in a large multi-dimensional solution space

  4. Important radiation protection aspects of the operation of a commercial medical cyclotron

    International Nuclear Information System (INIS)

    Mukherjee, B.

    1997-01-01

    Since July 1991 the Radiopharmaceutical Division of the Australian Nuclear Science and Technology Organisation (ANSTO) operates a 30 MeV H'- ion Medical Cyclotron (Model; CYCLONE 30, Manufacturer: Ion Beam Applications, Louvain La Neuve, Belgium). During routine isotope production operations at the cyclotron a thick copper substrate plate electroplated with thin layer of selected enriched target material are bombarded with 30 MeV proton beam current up to 450 μA. The nuclear reaction of protons with the copper atoms result in the reduction of prompt evaporation neutrons with a peak energy of ∼ 1.8 MeV. These evaporation neutrons slow down via multiple collisions with the concrete shielding walls of the target cave, bounce back to the,interior space of the cave activating the cyclotron parts, beam tube components and other utilities installed in the irradiation cave. After the completion of 60 hour isotope production run, gamma dose equivalent rates of ∼10 5 μSvh -1 were measured at contact with the target irradiation stations and beam collimators. Evidently, these gamma rays emitted from the activated cyclotron components impose crucial radiation exposure hazard problems for the cyclotron maintenance technicians. Experiments had been carried out in order to identify the specific pathways of cyclotron component activation and to assess the probable personnel radiation exposure during handling of the activated cyclotron parts. The cool-down (radioactive decay) of the activated cyclotron components was estimated experimentally at different target bombardment conditions using the wall mounted gamma area monitors interfaced to the Health Physics Data Acquisition System. The gamma dose equivalent rates at contact with various locations of interest at the target irradiation station and at the typical work areas of the maintenance personnel were carefully recorded with a radiation (gamma) survey instrument during the three years operation period of the cyclotron. A

  5. Commercial and PET radioisotope manufacturing with a medical cyclotron

    International Nuclear Information System (INIS)

    Boothe, T.E.; McLeod, T.F.; Plitnikas, M.; Kinney, D.; Tavano, E.; Feijoo, Y.; Smith, P.; Szelecsenyi, F.

    1993-01-01

    Mount Sinai has extensive experience in producing radionuclides for commercial sales and for incorporation into radiopharmaceuticals, including PET. Currently, an attempt is being made to supply radiochemicals to radiopharmaceutical manufacturers outside the hospital, to prepare radiopharmaceuticals for in-house use, and to prepare PET radiopharmaceuticals, such as 2-[F-18] FDG, for outside sales. This use for both commercial and PET manufacturing is atypical for a hospital-based cyclotron. To accomplish PET radiopharmaceutical sales, the hospital operates a nuclear pharmacy. A review of operational details for the past several years shows a continuing dependence on commercial sales which is reflected in research and developmental aspects and in staffing. Developmental efforts have centered primarily on radionuclide production, target development, and radiochemical processing optimization. (orig.)

  6. Commercial and PET radioisotope manufacturing with a medical cyclotron

    Science.gov (United States)

    Boothe, T. E.; McLeod, T. F.; Plitnikas, M.; Kinney, D.; Tavano, E.; Feijoo, Y.; Smith, P.; Szelecsényi, F.

    1993-06-01

    Mount Sinai has extensive experience in producing radionuclides for commercial sales and for incorporation into radiopharmaceuticals, including PET. Currently, an attempt is being made to supply radiochemicals to radiopharmaceutical manufacturers outside the hospital, to prepare radiopharmaceuticals for in-house use, and to prepare PET radiopharmaceuticals, such as 2-[F-18] FDG, for outside sales. This use for both commercial and PET manufacturing is atypical for a hospital-based cyclotron. To accomplish PET radiopharmaceutical sales, the hospital operates a nuclear pharmacy. A review of operational details for the past several years shows a continuing dependence on commercial sales which is reflected in research and developmental aspects and in staffing. Developmental efforts have centered primarily on radionuclide production, target development, and radiochemical processing optimization.

  7. Medical radioisotopes production at the isochronous cyclotron in Alma-Ata

    International Nuclear Information System (INIS)

    Arzumanov, A.A.; Batischev, V.N.; Gladun, V.K.; Kochetkov, V.L.

    1988-01-01

    High efficiency cyclotron operations (up to 5200 hours of beam time a year) considerably increased the possibility to perform both fundamental and applied scientific work. There appeared possibility to accelerate protons in a wide energy range from 6 to 30 MeV and realize correspondingly the nuclear reactions up to (A, 3n). This paper reports that among different applied tasks performed at the cyclotron the special program of cyclotron production of short-lived medical radioisotopes iodine-123, thallium-201, cadmium-109 in the first place and some others to satisfy clinic needs of Alma-Ata and its region has special importance. In accordance with this program the preparation to produce iodine-123 is being held and regular production of Thallium chloride, thallium-201 pharmaceptical is started

  8. A real-time intercepting beam-profile monitor for a medical cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Hendriks, C.; Uittenbosch, T.; Cameron, D.; Kellogg, S.; Gray, D.; Buckley, K.; Schaffer, P.; Verzilov, V.; Hoehr, C. [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada)

    2013-11-15

    There is a lack of real-time continuous beam-diagnostic tools for medical cyclotrons due to high power deposition during proton irradiation. To overcome this limitation, we have developed a profile monitor that is capable of providing continuous feedback about beam shape and current in real time while it is inserted in the beam path. This enables users to optimize the beam profile and observe fluctuations in the beam over time with periodic insertion of the monitor.

  9. Neutron measurements at BRIT/BARC medical cyclotron facility of RMC, Parel

    International Nuclear Information System (INIS)

    Sathian, Deepa; Sathian, V.; Phandnis, U.V.; Soni, P.S.; Mohite, D.Y.

    2005-01-01

    Neutron leakage and its long distance propagation in the atmosphere from the intense neutron facilities such as high energy accelerators like Cyclotron are very important for the shielding design of the facilities and resulting dose reduction to nearby population, because of strong penetrability of high energy neutrons. The neutron interaction cross sections are highly energy dependent, so different methods are adopted for measuring different energy neutrons. The method also depends on the amount of neutron fluence rate expected at the location. When the fluence rate is very high, the foil activation is the best method for the measurement of neutron fluence rate. In foil activation technique an inactive material is activated by neutrons and the activity is measured and correlated to the neutron fluence rate. In this paper, neutron fluence rate measurement using different activation foils at medical cyclotron room of Radiation Medicine Centre (RMC) is discussed. (author)

  10. Direct production of 99mTc using a small medical cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Lapi, Suzanne [Washington Univ., St. Louis, MO (United States)

    2017-10-03

    This project describes an investigation towards the production of 99mTc with a small medical cyclotron. This endeavor addresses the current urgent problem of availability of 99mTc due to the ongoing production reactor failures and the upcoming Canadian reactor shut down. Currently, 99mTc is produced via nuclear fission using highly enriched uranium which is a concern due to nuclear proliferation risks. In addition to this, the United States is dependent solely on currently unreliable foreign sources of this important medical isotope. Clearly, a need exists to probe alternative production routes of 99mTc. In the first year, this project measured cross-sections and production yields of potential pathways to 99mTc and associated radionuclidic impurities produced via these pathways using a small 15 MeV medical cyclotron. During the second and third years target systems for the production of 99mTc via the most promising reaction routes were developed and separation techniques for the isolation of 99mTc from the irradiated target material will be investigated. Systems for the recycling of the enriched target isotopes as well as automated target processing systems were examined in years four and five. This project has the potential to alleviate some of the current crisis in the medical community by developing a technique to produce 99mTc on location at a university hospital. This technology will be applicable at many other sites in the United States as many other similar, low energy (<20 MeV) cyclotrons (currently used for a few hours per day for the production of [18F]fluorodeoxyglucose) are available for production of 99mTc though this method, thus leading to job creation and preservation.

  11. Comparison of the production of medical radioisotopes on reactor and cyclotron

    International Nuclear Information System (INIS)

    Vucina, J.; Vuksanovic, Lj.; Dobrijevic, R.; Karanfilov, E.

    1997-01-01

    The production of radioisotopes for nuclear-medical applications can be performed either on nuclear reactor or on cyclotron. According to the nuclear reactions applied the radioisotopes of different physical characteristics can be produced. In the paper a comparison of the radioisotopes production given. Compared are the main steps in the production: choice of the nuclear reaction, targetry, irradiation and radiochemical separations performed on the irradiated target to isolate the desired radioisotope. The main characteristics of the produced radioisotopes are given and discussed. (author)

  12. An analytical approach of thermodynamic behavior in a gas target system on a medical cyclotron.

    Science.gov (United States)

    Jahangiri, Pouyan; Zacchia, Nicholas A; Buckley, Ken; Bénard, François; Schaffer, Paul; Martinez, D Mark; Hoehr, Cornelia

    2016-01-01

    An analytical model has been developed to study the thermo-mechanical behavior of gas targets used to produce medical isotopes, assuming that the system reaches steady-state. It is based on an integral analysis of the mass and energy balance of the gas-target system, the ideal gas law, and the deformation of the foil. The heat transfer coefficients for different target bodies and gases have been calculated. Excellent agreement is observed between experiments performed at TRIUMF's 13 MeV cyclotron and the model. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Performance test of electron cyclotron resonance ion sources for the Hyogo Ion Beam Medical Center

    Science.gov (United States)

    Sawada, K.; Sawada, J.; Sakata, T.; Uno, K.; Okanishi, K.; Harada, H.; Itano, A.; Higashi, A.; Akagi, T.; Yamada, S.; Noda, K.; Torikoshi, M.; Kitagawa, A.

    2000-02-01

    Two electron cyclotron resonance (ECR) ion sources were manufactured for the accelerator facility at the Hyogo Ion Beam Medical Center. H2+, He2+, and C4+ were chosen as the accelerating ions because they have the highest charge to mass ratio among ion states which satisfy the required intensity and quality. The sources have the same structure as the 10 GHz ECR source at the Heavy Ion Medical Accelerator in Chiba except for a few improvements in the magnetic structure. Their performance was investigated at the Sumitomo Heavy Industries factory before shipment. The maximum intensity was 1500 μA for H2+, 1320 μA for He2+, and 580 μA for C4+ at the end of the ion source beam transport line. These are several times higher than required. Sufficient performance was also observed in the flatness and long-term stability of the pulsed beams. These test results satisfy the requirements for medical use.

  14. Occupational radiation exposure at the self-shielded IBA CYCLONE 10/5, cyclotron of the Austin and Repatriation Medical Centre, Melbourne, Australia

    International Nuclear Information System (INIS)

    Tochon-Danguy, H.; Sachinidis, J.I.; U, P.; Egan, G.; Mukherjee, B.

    1999-01-01

    A series of health physics measurements was carried out at the IBA CYCLONE 10/5 Medical Cyclotron of the Austin and Repatriation Medical Centre, Melbourne. The neutron attenuation factor of the cyclotron shielding was estimated using the Superheated Bubble dosimeters. The neutron and gamma dose rates at various public access and radiation worker's area in the vicinity of the cyclotron facility were evaluated during the 11 C, 18 F, 13 N and 15 O production conditions. (authors)

  15. Recent achievements in Tc-99m radiopharmaceutical direct production by medical cyclotrons.

    Science.gov (United States)

    Boschi, Alessandra; Martini, Petra; Pasquali, Micol; Uccelli, Licia

    2017-09-01

    99m Tc is the most commonly used radionuclide in the field of diagnostic imaging, a noninvasive method intended to diagnose a disease, assess the disease state and monitor the effects of treatments. Annually, the use of 99m Tc, covers about 85% of nuclear medicine applications. This isotope releases gamma rays at about the same wavelength as conventional X-ray diagnostic equipment, and owing to its short half-life (t ½  = 6 h) is ideal for diagnostic nuclear imaging. A patient can be injected with a small amount of 99m Tc and within 24 h almost 94% of the injected radionuclide would have decayed and left the body, limiting the patient's radiation exposure. 99m Tc is usually supplied to hospitals through a 99 Mo/ 99m Tc radionuclide generator system where it is produced from the β decay of the parent nuclide 99 Mo (t ½  = 66 h), which is produced in nuclear reactors via neutron fission. Recently, the interruption of the global supply chain of reactor-produced 99 Mo, has forced the scientific community to investigate alternative production routes for 99m Tc. One solution was to consider cyclotron-based methods as potential replacement of reactor-based technology and the nuclear reaction 100 Mo(p,2n) 99m Tc emerged as the most worthwhile approach. This review reports some achievements about 99m Tc produced by medical cyclotrons. In particular, the available technologies for target design, the most efficient extraction and separation procedure developed for the purification of 99m Tc from the irradiated targets, the preparation of high purity 99m Tc radiopharmaceuticals and the first clinical studies carried out with cyclotron produced 99m Tc are described.

  16. Solid targets for 99mTc production on medical cyclotrons

    International Nuclear Information System (INIS)

    Hanemaayer, V.; Buckley, K.R.; Klug, J.; Ruth, T.J.; Schaffer, P.; Zeisler, S.K.; Benard, F.; Kovacs, M.; Leon, C.

    2014-01-01

    Recent disruptions in the molybdenum-technetium generator supply chain prompted a review of non-reactor based production methods for both 99 Mo and 99m Tc. Small medical cyclotrons (E p ∼ 16-24 MeV) are capable of producing Curie quantities of 99m Tc from isotopically enriched 100 Mo using the 100 Mo(p,2n) 99m Tc reaction. Unlike most other metallic target materials for routine production of medical radioisotopes, molybdenum cannot be deposited by reductive electroplating from aqueous salt solutions. To overcome this issue, we developed a new process for solid molybdenum targets based on the electrophoretic deposition of fine 100 Mo powder onto a tantalum plate, followed by high temperature sintering. The targets obtained were mechanically robust and thermally stable when irradiated with protons at high power density. (author)

  17. Proposed medical applications of the National Accelerator Centre facilities

    International Nuclear Information System (INIS)

    Jones, D.T.L.

    1982-01-01

    The National Accelerator Centre is at present under construction at Faure, near Cape Town. The complex will house a 200 MeV separated-sector cyclotron which will provide high quality beams for nuclear physics and related diciplines as well as high intensity beams for medical use. The medical aspects catered for will include particle radiotherapy, isotope production and possibly proton radiography. A 30-bed hospital is to be constructed on the site. Building operations are well advanced and the medical facilities should be available for use by the end of 1984

  18. Digital Data Acquisition System for experiments with segmented detectors at National Superconducting Cyclotron Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Starosta, K., E-mail: starosta@sfu.c [National Superconducting Cyclotron Laboratory and Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Vaman, C.; Miller, D.; Voss, P.; Bazin, D.; Glasmacher, T. [National Superconducting Cyclotron Laboratory and Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Crawford, H.; Mantica, P. [National Superconducting Cyclotron Laboratory and Department of Chemistry, Michigan State University, East Lansing, MI 48824 (United States); Tan, H.; Hennig, W.; Walby, M.; Fallu-Labruyere, A.; Harris, J.; Breus, D.; Grudberg, P.; Warburton, W.K. [XIA LLC, Hayward, CA 94544 (United States)

    2009-11-11

    A 624-channel Digital Data Acquisition System capable of instrumenting the Segmented Germanium Array at National Superconducting Cyclotron Laboratory has been implemented using Pixie-16 Digital Gamma Finder modules by XIA LLC. The system opens an opportunity for determination of the first interaction position of a gamma ray in a SeGA detector from implementation of gamma-ray tracking. This will translate into a significantly improved determination of angle of emission, and in consequence much better Doppler corrections for experiments with fast beams. For stopped-beam experiments the system provides means for zero dead time measurements of rare decays, which occur on time scales of microseconds.

  19. Digital Data Acquisition System for experiments with segmented detectors at National Superconducting Cyclotron Laboratory

    International Nuclear Information System (INIS)

    Starosta, K.; Vaman, C.; Miller, D.; Voss, P.; Bazin, D.; Glasmacher, T.; Crawford, H.; Mantica, P.; Tan, H.; Hennig, W.; Walby, M.; Fallu-Labruyere, A.; Harris, J.; Breus, D.; Grudberg, P.; Warburton, W.K.

    2009-01-01

    A 624-channel Digital Data Acquisition System capable of instrumenting the Segmented Germanium Array at National Superconducting Cyclotron Laboratory has been implemented using Pixie-16 Digital Gamma Finder modules by XIA LLC. The system opens an opportunity for determination of the first interaction position of a γ ray in a SeGA detector from implementation of γ-ray tracking. This will translate into a significantly improved determination of angle of emission, and in consequence much better Doppler corrections for experiments with fast beams. For stopped-beam experiments the system provides means for zero dead time measurements of rare decays, which occur on time scales of microseconds.

  20. Digital Data Acquisition System for experiments with segmented detectors at National Superconducting Cyclotron Laboratory

    Science.gov (United States)

    Starosta, K.; Vaman, C.; Miller, D.; Voss, P.; Bazin, D.; Glasmacher, T.; Crawford, H.; Mantica, P.; Tan, H.; Hennig, W.; Walby, M.; Fallu-Labruyere, A.; Harris, J.; Breus, D.; Grudberg, P.; Warburton, W. K.

    2009-11-01

    A 624-channel Digital Data Acquisition System capable of instrumenting the Segmented Germanium Array at National Superconducting Cyclotron Laboratory has been implemented using Pixie-16 Digital Gamma Finder modules by XIA LLC. The system opens an opportunity for determination of the first interaction position of a γ ray in a SeGA detector from implementation of γ-ray tracking. This will translate into a significantly improved determination of angle of emission, and in consequence much better Doppler corrections for experiments with fast beams. For stopped-beam experiments the system provides means for zero dead time measurements of rare decays, which occur on time scales of microseconds.

  1. Proposed full automatic control system for the Medical Small Cyclotron C-30 at the Institute of Nuclear Studies, Poland

    International Nuclear Information System (INIS)

    Jankowski, A.

    1987-01-01

    The computer control system for the C-30 Medical Small Cyclotron, which is currently under construction at the Institute of Nuclear Studies will be presented. The features of this simple and secure system are briefly discussed. Some efforts have been done to make a conversational system easily understandable for operators. The keystone of the control system is an fibre optical link (wireless) between the cyclotron and the computer. The control system is based on the use of an extended configuration of the IBM PC/AT computer. A new system software is used to execute multitask hierarchical programs to control the cyclotron. The comercial adapters for control and data aquisition, connected with the fibre optic communication channels are used to transmit data and control codes. Two colour graphic CRT displays the ongoing status and function of each controlled units so that the operator can monitor the whole system conditions at a glance. The paper gives a general description of the programs which are executed on the computer. It also shows how the cyclotron is controlled by dedicated computer practically without special electronic equipment except of the hardware safety cutout switch. The cyclotron is protected against operating incidents and mistakes by a complex system of interlocks. (author)

  2. A prediction model for the radiation safety management behavior of medical cyclotrons

    International Nuclear Information System (INIS)

    Jung, Ji Hye; Han, Eun Ok; Kim, Ssang Tae

    2008-01-01

    This study attempted to provide reference materials for improving the behavior level in radiation safety managements by drawing a prediction model that affects the radiation safety management behavior because the radiation safety management of medical Cyclotrons, which can be used to produce radioisotopes, is an important factor that protects radiation caused diseases not only for radiological operators but average users. In addition, this study obtained follows results through the investigation applied from January 2 to January 30, 2008 for the radiation safety managers employed in 24 authorized organizations, which have already installed Cyclotrons, through applying a specific form of questionnaire in which the validity was guaranteed by reference study, site investigation, and focus discussion by related experts. The radiation safety management were configured as seven steps: step 1 is a production preparation step, step 2 is an RI production step, step 3 is a synthesis step, step 4 is a distribution step, step 5 is a quality control step, step 6 is a carriage container packing step, and step 7 is a transportation step. It was recognized that the distribution step was the most exposed as 15 subjects (62.5%), the items of 'the sanction and permission related works' and 'the guarantee of installation facilities and production equipment' were the most difficult as 9 subjects (37.5%), and in the trouble steps in such exposure, the item of 'the synthesis and distribution' steps were 4 times, respectively (30.8%). In the score of the behavior level in radiation safety managements, the minimum and maximum scores were 2.42 and 4.00, respectively, and the average score was 3.46 ± 0.47 out of 4. Prosperity and well-being programs in the behavior and job in radiation safety managements (r=0.529) represented a significant correlation statistically. In the drawing of a prediction model based on the factors that affected the behavior in radiation safety managements, general

  3. A prediction model for the radiation safety management behavior of medical cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Ji Hye; Han, Eun Ok [Daegu Health College, Daegu (Korea, Republic of); Kim, Ssang Tae [CareCamp Inc., Seoul (Korea, Republic of)

    2008-06-15

    This study attempted to provide reference materials for improving the behavior level in radiation safety managements by drawing a prediction model that affects the radiation safety management behavior because the radiation safety management of medical Cyclotrons, which can be used to produce radioisotopes, is an important factor that protects radiation caused diseases not only for radiological operators but average users. In addition, this study obtained follows results through the investigation applied from January 2 to January 30, 2008 for the radiation safety managers employed in 24 authorized organizations, which have already installed Cyclotrons, through applying a specific form of questionnaire in which the validity was guaranteed by reference study, site investigation, and focus discussion by related experts. The radiation safety management were configured as seven steps: step 1 is a production preparation step, step 2 is an RI production step, step 3 is a synthesis step, step 4 is a distribution step, step 5 is a quality control step, step 6 is a carriage container packing step, and step 7 is a transportation step. It was recognized that the distribution step was the most exposed as 15 subjects (62.5%), the items of 'the sanction and permission related works' and 'the guarantee of installation facilities and production equipment' were the most difficult as 9 subjects (37.5%), and in the trouble steps in such exposure, the item of 'the synthesis and distribution' steps were 4 times, respectively (30.8%). In the score of the behavior level in radiation safety managements, the minimum and maximum scores were 2.42 and 4.00, respectively, and the average score was 3.46 {+-} 0.47 out of 4. Prosperity and well-being programs in the behavior and job in radiation safety managements (r=0.529) represented a significant correlation statistically. In the drawing of a prediction model based on the factors that affected the behavior in

  4. Evaluating secondary neutron doses of a refined shielded design for a medical cyclotron using the TLD approach

    International Nuclear Information System (INIS)

    Lin, Jye-Bin; Tseng, Hsien-Chun; Liu, Wen-Shan; Lin, Ding-Bang; Hsieh, Teng-San; Chen, Chien-Yi

    2013-01-01

    An increasing number of cyclotrons at medical centers in Taiwan have been installed to generate radiopharmaceutical products. An operating cyclotron generates immense amounts of secondary neutrons from reactions such the 18 O(p, n) 18 F, used in the production of FDG. This intense radiation can be hazardous to public health, particularly to medical personnel. To increase the yield of 18 F-FDG from 4200 GBq in 2005 to 48,600 GBq in 2011, Chung Shan Medical University Hospital (CSMUH) has prolonged irradiation time without changing the target or target current to meet requirements regarding the production 18 F. The CSMUH has redesigned the CTI Radioisotope Delivery System shield. The lack of data for a possible secondary neutron doses has increased due to newly designed cyclotron rooms. This work aims to evaluate secondary neutron doses at a CTI cyclotron center using a thermoluminescent dosimeter (TLD-600). Two-dimensional neutron doses were mapped and indicated that neutron doses were high as neutrons leaked through self-shielded blocks and through the L-shaped concrete shield in vault rooms. These neutron doses varied markedly among locations close to the H 2 18 O target. The Monte Carlo simulation and minimum detectable dose are also discussed and demonstrated the reliability of using the TLD-600 approach. Findings can be adopted by medical centers to identify radioactive hot spots and develop radiation protection. - Highlights: • Neutron doses were verified using TLD approach. • Neutron doses were increased at cyclotron centers. • Revised L-shaped shield suppresses effectively the neutrons. • Neutron dose can be attenuated to 1.13×10 6 %

  5. The production of cyclotron radioisotopes and radiopharmaceuticals at the national accelerator centre in South Africa

    International Nuclear Information System (INIS)

    Walt, T.N. van der

    1998-01-01

    Accelerator radioisotopes have been manufactured in South Africa since 1965 with the 30 MeV cyclotron at the Council for Scientific and Industrial Research (CSIR) in Pretoria. After its closure in 1988, the radioisotope production programme was continued at the National Accelerator Centre (NAC) with the 200 MeV separated sector cyclotron (SCC) utilizing the 66 MeV proton beam, which is shared with the neutron therapy programme during part of the week. A variety of radiopharmaceuticals, such as 18 F-FDG, 67 Ga-citrate, a 67 Ga-labelled resin. 111 In-chloride, 111 In-oxine and 111 In-labelled resin. 123 I-sodium iodide and 123 I-labelled compounds, 201 Tl-chloride, as well as the 81 Rb/ 81m Kr gas generator, are prepared for use in the nuclear medicine departments of 12 State hospitals and about 28 private nuclear medicine clinics in South Africa. A few longer-lived radioisotopes, such as 22 Na, 55 Fe and 139 Ce, are also produced for research or industrial use. A research and development programme is running to develop new production procedures to produce radioisotopes and radiopharmaceuticals, or to improve existing production procedures. As part of a programme to utilize the beam time optimally, the production of some other radioisotopes is investigated. (author)

  6. Beam stability of cyclotron accelerator for therapy at National Cancer Center Hospital East

    International Nuclear Information System (INIS)

    Nishio, T.; Ogino, T.; Shinbo, M.; Ikeda, H.; Tachikawa, T.; Kumata, Y.

    2000-01-01

    In 1997, the proton-treatment facility that has the therapeutic AVF cyclotron accelerator (C235), is constructed at National Cancer Center Hospital East. The facility has 3-irradiation ports (rooms) that are 2-rotationg gantry ports and 1-horizontal fixed port. The C235 can accelerate proton to 235 MeV with the beam intensity of 300 nA. The external diameter is a very compact with about 4 m. The radio frequency is 106 MHz, the accelerating voltage is about 60 kV, and the harmonic number is 4. A beam stability of the C235 has an important relation with the uniformity of an irradiation field and is a very difficulty. The measured result indicated that the incident beam position must be into the 0.5-mmφ circle. (author)

  7. Current status of Australian Radioisotopes, the National Medicine Cyclotron and the Biomedicine and Health Program at Ansto

    International Nuclear Information System (INIS)

    Garnett, H.

    1995-01-01

    An overview is provided of the current roles of Australian Radioisotopes, the National Medicine Cyclotron, and the Biomedicine and Health Program in the light of the recommendations of the recent Bain/Battelle review of ANSTO which was commissioned by the ANSTO's Board in 1994

  8. Medical isotope production experience at the V.G. Khlopin Radium Institute cyclotron

    International Nuclear Information System (INIS)

    Solin, L.M.

    2000-01-01

    Radium Institute cyclotron MGC-20 is used since 1990. There are four cyclotrons of such type in Russia and four abroad: in Finland, in Hungary, in North Korea and in Egypt. The Radium institute cyclotron was used in different fields, such as radioisotope production, nuclear physics, physics and engineering. For ten years some improvements of the Radium Institute cyclotron operation have been made. Those are: creation of the automatic control system based on IBM PC, development of a new power supply for the ion source, creation of the deflector electronic protection from discharges, change of the main elements of the cyclotron with high induced radioactivity. Moreover we investigated the possibility of the negative ions acceleration at the MGC-20 cyclotron without ion source exchange. The maximum value of the proton beam current reached was about 30 μA for 10 MeV H - beam energy. To extract the proton beam from the cyclotron after the stripping foil we made an additional output beam line. It was used for determination of the horizontal and vertical emittance. A special device was constructed and used for measurements of emittance. The latter amounted 30 π mm mrad for horizontal direction and 16 π mm mrad for vertical direction

  9. One year's experience of the WA medical cyclotron and radiopharmaceutical production facility

    International Nuclear Information System (INIS)

    DeRoach, J.; Tuchyna, T.; Jones, C.; Price, R.

    2004-01-01

    Full text: The WA PET Centre Medical Cyclotron, a facility novel in Western Australia, produced its first bolus of FDG for patient injection for PET scanning in August 2003. This paper describes the methodology and practices employed during the past 12 months for ensuring that reliable routine provision of FDG is maintained, in parallel with facilitating the development and production of achievable new radiopharmaceuticals. An FDG production team of six staff and, a maintenance and development team of 4 staff were created from the 3.4 staff specifically recruited for this service and from incumbent staff. Teams were also set up to carry out development projects related to the service. Training procedures were created under the department's ISO9001:2000 accreditation system for the certification of production and maintenance staff. Practices and documentation systems were put in place in anticipation of a pending cGMP audit. Several unplanned major changes to equipment and infrastructure were necessary post commissioning. These changes included purchase of a different FDG synthesis module from that originally supplied, and modifications to engineering services, including changes to air conditioning, changes to supply of vacuum and upgrading of drainage in the laboratory area. A device for the measurement of end of bombardment yield was built, so that the efficiencies of the various synthesis modules could be accurately determined. Strict radiation protection procedures were put in place. All staff were provided with luxels and finger TLDs for monthly reporting of their radiation levels, as well as electronic monitors for real-time monitoring. From August 2003 to June 2004 (11 months) 2229 FDG patient doses were produced and dispensed by this facility. An average of 8.0 patient doses per available working day were dispensed during the 2003 period, rising to 11.1 patient doses per day in 2004. Several 11 NH3 doses were also delivered. The cyclotron was unavailable for

  10. The Study of 99mTc Production Using Medical Cyclotrons in Ukraine

    Directory of Open Access Journals (Sweden)

    Borys M. Bondar

    2017-12-01

    Conclusions. The obtained results showed satisfied 99mTс tracer yields and feasibility of further development of this method, which will significantly improve the efficiency of cyclotron installations.

  11. Distribution of residual long-lived radioactivity in the inner concrete walls of a compact medical cyclotron vault room.

    Science.gov (United States)

    Fujibuchi, Toshioh; Nohtomi, Akihiro; Baba, Shingo; Sasaki, Masayuki; Komiya, Isao; Umedzu, Yoshiyuki; Honda, Hiroshi

    2015-01-01

    Compact medical cyclotrons have been set up to generate the nuclides necessary for positron emission tomography. In accelerator facilities, neutrons activate the concrete used to construct the vault room; this activation increases with the use of an accelerator. The activation causes a substantial radioactive waste management problem when facilities are decommissioned. In the present study, several concrete cores from the walls, ceiling and floor of a compact medical cyclotron vault room were samples 2 years after the termination of operations, and the radioactivity concentrations of radionuclides were estimated. Cylindrical concrete cores 5 cm in diameter and 10 cm in length were bored from the concrete wall, ceiling and floor. Core boring was performed at 18 points. The gamma-ray spectrum of each sample was measured using a high-purity germanium detector. The degree of activation of the concrete in the cyclotron vault room was analyzed, and the range and tendency toward activation in the vault room were examined. (60)Co and (152)Eu were identified by gamma-ray spectrometry of the concrete samples. (152)Eu and (60)Co are produced principally from the stable isotopes of europium and cobalt by neutron capture reactions. The radioactivity concentration did not vary much between the surface of the concrete and at a depth of 10 cm. Although the radioactivity concentration near the target was higher than the clearance level for radioactive waste indicated in IAEA RS-G-1.7, the mean radioactivity concentration in the walls and floor was lower than the clearance level. The radioactivity concentration of the inner concrete wall of the medical cyclotron vault room was not uniform. The areas exceeding the clearance level were in the vicinity of the target, but most of the building did not exceed the clearance levels.

  12. LIBO - boosting medical cyclotron facilities for cancer therapy Exhibition LEPFest 2000

    CERN Multimedia

    2000-01-01

    Length : Energy boost : From 62 to 200 MeVAccelerating gradient : 10 MeV/metreAccelerating frequency : 3 GHz Collaboration : CERN, INFN and University of Milan, INFN and University of Naples and TERA foundation Prototype test in 2001 : SC cyclotron Catania

  13. Radioisotope production in the I. Ph. P. E. cyclotron for medical application

    Energy Technology Data Exchange (ETDEWEB)

    Krasnov, N.N.; Dmitriyev, P.P.; Konjakhin, N.A.; Ognev, A.A. (Gosudarstvennyj Komitet po Ispol' zovaniyu Atomnoj Ehnergii SSSR, Obninsk. Fiziko-Ehnergeticheskij Inst.)

    1982-01-01

    The production methods for seven radioisotopes, Ga-67, Sr-85, Pd-103, In-111, Tm-167, Hg-197 and Pb-203, by using a classical 1.5m cyclotron in the Institute of Physics and Power Engineering, Obninsk, USSR, are described. At present, more than 50 cyclotrons in different countries are used for the production of radioisotopes applied to medicine. Radioisotopes are produced with the cyclotron in the I.Ph.P.E. in the form of irradiated targets, which are delivered to Moscow radiopharmaceutical factory, where radiopharmaceuticals are produced on the base of these targets. The cyclotron is operated in two regimes providing the acceleration of protons, deuterons and alpha -particles. Two types of target assemblies are used for irradiation, the one is intended for the internal beam, and the other is for the external beam. The reactions used for the production of seven radioisotopes described above, the types of targets, particle energy, respective irradiated materials, beam current, thick target yield and the amount of respective radioisotopes produced per year are reported. Metals have large heat conductivity, therefore the use of metal targets increases beam current, and increases the production rate of radioisotopes.

  14. A light, superconducting H- cyclotron for medical diagnostics and neutron radiography

    International Nuclear Information System (INIS)

    Finlan, M.F.; Kruip, M.; Wilson, M.N.

    1987-01-01

    Oxford Instruments, working in close collaboration with Amersham International are developing a compact, lightweight, low radiation field superconducting cyclotron. The combination of superconductivity, H - acceleration and no internal yoke as such makes this possible. It is intended for use as a generator of short half lived isotopes for use in hospitals for PET and other imaging procedures, for use in industrial PET imaging, and as a neutron generator for neutron radiography. With a weight of 2000 kg, it is transportable and comparitively easy to handle and is capable in the 17 MeV version of generating 1.8 10 13 neutrons/second for neutron radiography. (author)

  15. National cyclotron centre at the Institute for Nuclear Research and Nuclear Energy

    Science.gov (United States)

    Tonev, D.; Goutev, N.; Asova, G.; Artinyan, A.; Demerdjiev, A.; Georgiev, L. S.; Yavahchova, M.; Bashev, V.; Genchev, S. G.; Geleva, E.; Mincheva, M.; Nikolov, A.; Dimitrov, D. T.

    2018-05-01

    An accelerator laboratory is presently under construction in Sofia at the Institute for Nuclear Research and Nuclear Energy. The laboratory will use a TR24 type of cyclotron, which provides a possibility to accelerate a proton beam with an energy of 15 to 24 MeV and current of up to 0.4 mA. An accelerator with such parameters allows to produce a large variety of radioisotopes for development of radiopharmaceuticals. The most common radioisotopes that can be produced with such a cyclotron are PET isotopes like: 11C, 13N, 15O, 18F, 124I, 64Cu, 68Ge/68Ga, and SPECT isotopes like: 123I, 111In, 67Ga, 57Co, 99mTc. Our aim is to use the cyclotron facility for research in the fields of radiopharmacy, radiochemistry, radiobiology, nuclear physics, materials sciences, applied research, new materials and for education in all these fields including nuclear energy. Presently we perform investigations in the fields of target design for production of radioisotopes, shielding and radioprotection, new ion sources etc.

  16. Neutronigen target study and realization for medical cyclotron using proton reactions on lithium deuteride

    International Nuclear Information System (INIS)

    Filhol, J.M.

    1984-02-01

    The new idea, used for this source realization, consists of replacing the classical beryllium targets (usuals in neutronotherapy cyclotrons) by a half-thick lithium deuteride target. The target is bombarded by high energy 150 MeV) protons which are beyond the target, deviated out of the neutron beam by a permanent magnet, before to be stopped in a graphite block. Target cooling conditions study and optimisation is presented, followed by the proton deflection block study and realization. The permanent magnet used (SmCo 5 ) is adapted to this target use conditions. Many series of neutronic and dosimetric characteristics measurements allow to verify the theoretical predictions concerning the neutron flux obtained [fr

  17. Superconducting cyclotrons

    International Nuclear Information System (INIS)

    Blosser, H.G.; Johnson, D.A.; Burleigh, R.J.

    1976-01-01

    Superconducting cyclotrons are particularly appropriate for acceleration of heavy ions. A review is given of design features of a superconducting cyclotron with energy 440 (Q 2 /A) MeV. A strong magnetic field (4.6 tesla average) leads to small physical size (extraction radius 65 cm) and low construction costs. Operating costs are also low. The design is based on established technology (from present cyclotrons and from large bubble chambers). Two laboratories (in Chalk River, Canada and in East Lansing, Michigan) are proceeding with construction of full-scale prototype components for such cyclotrons

  18. National Ambulatory Medical Care Survey (NAMCS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Ambulatory Medical Care Survey (NAMCS) is a national survey designed to meet the need for objective, reliable information about the provision and use of...

  19. Cyclotrons: 1978

    International Nuclear Information System (INIS)

    Martin, J.A.

    1978-01-01

    A compilation is presented of the experimental facilities of the world's cyclotrons including history and status, staff and operation, research staff, target facilities, magnet, acceleration system, vacuum system, characteristic beams, beam properties, and a plan view of the facility for each cyclotron

  20. Measurements and evaluation of the risks due to external radiation exposures and to intake of activated elements for operational staff engaged in the maintenance of medical cyclotrons.

    Science.gov (United States)

    Calandrino, R; del Vecchio, A; Parisi, R; Todde, S; De Felice, P; Savi, A; Pepe, A; Mrskova, A

    2010-06-01

    The aim of this paper is to assess the activation phenomena and to evaluate the risk of external exposure and intake doses for the maintenance staff of two medical cyclotrons. Two self-shielded cyclotrons are currently operating in the facility for the routine production of (11)C and (18)F. Four radiochemistry laboratories are linked to the cyclotrons by means of shielded radioisotope delivery lines. Radiopharmaceuticals are prepared both for the PET Diagnostic Department, where four CT-PET scanners are operating with a mean patient workload of 40 d(-1) and for [(18)F]FDG external distribution, to provide radiopharmaceuticals for other institutions. In spite of the fact that air contamination inside the radiochemistry laboratories during the synthesis represents the largest 'slice of the pie' in the evaluation of annual intake dose, potential contamination due to the activated particulate, generated during cyclotron irradiation by micro-corrosion of targets and other components potentially struck by the proton beam and generated neutrons, should be considered. In this regard, the most plausible long-lived (T(1/2) > 30 d) radioisotopes formed are: (97)Tc, (56)Co, (57)Co, (58)Co, (60)Co, (49)V, (55)Fe, (109)Cd, (65)Zn and (22)Na. The results for the operating personnel survey has revealed only low-level contamination for (65)Zn in one test, together with minor (18)F intake, probably due to the environmental dispersion of the radioisotope during the [(18)F]FDG synthesis.

  1. How cyclotrons work

    International Nuclear Information System (INIS)

    Nolan, D.

    1992-01-01

    The operating principles of a cyclic accelerator are presented based on the IBA Cyclone 30 negative ion cyclotron, selected for the Australia's first medical cyclotron. Its main features are: acceleration with variable energy of between 15-30 million electron volts, the capability of extracting two beams simultaneously, low power consumption, easy maintenance. Other aspects not directly related to the principle of operation discussed include the vacuum and the radio-frequency systems as well as the complex computerized control system used to automatically control start-up and shut-down operations. ills

  2. National Institute of General Medical Sciences

    Science.gov (United States)

    ... Over Navigation Links National Institute of General Medical Sciences Site Map Staff Search My Order Search the ... NIGMS Website Research Funding Research Training News & Meetings Science Education About NIGMS Feature Slides View All Slides ...

  3. National Hospital Ambulatory Medical Care Survey

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Hospital Ambulatory Medical Care Survey (NHAMCS) is designed to collect data on the utilization and provision of ambulatory care services in hospital...

  4. Development of HM12 cyclotron for PET

    International Nuclear Information System (INIS)

    Morita, Takuzo; Kawama, Tetsuo; Fujii, Kazuo

    2000-01-01

    In Japan, there are at present more than 30 PET (Positron Emission Tomography) facilities. The movements of medical insurance application to the PET diagnosis using [ 18 F] FDG (2-[ 18 F]-fluoro-2-deoxy-glucose) by the Ministry of Health and Welfare are being enhanced by PET related people. Therefore, more clinical centers using PET system are expected to be built in the near future. HM12 cyclotron was developed to meet such market demands for PET, and the prototype machine has been rent to Cyclotron Radio Isotope Center (CYRIC) of Tohoku University since Oct. 1998 for their use of clinical research with positron emitters like 11 C, 13 N, 15 O and 18 F. We got many technical data of HM12 Cyclotron on the clinical base. The data was enough to establish the reliability of HM12 system operation under the clinical condition. The first commercial product of HM12 Cyclotron was delivered to National Cancer Center in March 2000. The final performance test will be finished by the end of June 2000. (author)

  5. First two operational years of the electron-beam ion trap charge breeder at the National Superconducting Cyclotron Laboratory

    Directory of Open Access Journals (Sweden)

    A. Lapierre

    2018-05-01

    Full Text Available The electron-beam ion trap (EBIT charge breeder of the ReA post-accelerator, located at the National Superconducting Cyclotron Laboratory (Michigan State University, started on-line operation in September 2015. Since then, the EBIT has delivered many pilot beams of stable isotopes and several rare-isotope beams. An operating aspect of the ReA EBIT is the breeding of high charge states to reach high reaccelerated beam energies. Efficiencies in single charge states of more than 20% were measured with ^{39}K^{15+}, ^{85}Rb^{27+}, ^{47}K^{17+}, and ^{34}Ar^{15+}. Producing high charge states demands long breeding times. This reduces the ejection frequency and, hence, increases the number of ions ejected per pulse. Another operating aspect is the ability to spread the distribution in time of the ejected ion pulses to lower the instantaneous rate delivered to experiments. Pulse widths were stretched from a natural 25  μs up to ∼70  ms. This publication reviews the progress of the ReA EBIT system over the years and presents the results of charge-breeding efficiency measurements and pulse-stretching tests obtained with stable- and rare-isotope beams. Studies performed with high sensitivity to identify and quantify stable-isotope contaminants from the EBIT are also presented, along with a novel method for purifying beams.

  6. Initiatives in national and international collaborations at Variable Energy Cyclotron Centre

    International Nuclear Information System (INIS)

    Viyogi, Yogendra Pathak; Chakrabarti, Alok

    2008-01-01

    Over the last two decades VECC scientists, under the leadership of their director Bikash Sinha, have pursued experimental physics studies under international collaboration programmes, which would not have been possible with the existing facilities at home. The collaboration extended from RIKEN (Japan) in the east to CERN (Switzerland) in the west. It spanned the energy scales from a few tens of MeV per nucleon to several hundred GeV per nucleon and the physics topics on one extreme being the structure of exotic nuclei and their decay modes and on other extreme being the phase transition of hadronic matter and the formation of quark gluon plasma. The dynamic leadership of Dr. Sinha not only helped to shed the initial inhibitions towards such activities, going beyond the national frontiers, but also gave a new dimension to the experimental physics research in the country. It helped to organize an Indian team of scientists from various national institutes and universities. It paved way for full scale funding of the projects and set the trend that enabled many other Indian groups to join several international collaborations in various fields. Here we reflect on the evolution of these national and international collaboration programmes and the physics, technological and sociological benefits resulting from these activities. (author)

  7. Feasibility Study for a Two-Energy Compact Medical Cyclotron Controlled by Two Pairs of Main Coils

    International Nuclear Information System (INIS)

    Blum, D.; Breckow, J.; Zink, K.

    2013-01-01

    At Paul Scherrer Institute, Villigen, Switzerland, protons are accelerated for the proton therapy by a 250 MeV isochronous cyclotron. As for radiotherapy less energy is required (about 70 MeV) a carbon degrader reduces the extracted beam energy. This involves the increase of emittance, decrease of transmission, more activated components and a higher dose for the staff. By extracting a lower energy beam from the cyclotron, less degrade would be necessary and the above mentioned side-effects could be minimized. A possible solution could be to extract two energies from the cyclotron, 250 MeV for very deep located tumours and 230-235 MeV for others. A technically easy and affordable solution for this problem might be a two-energy cyclotron controlled by just two pairs of main coils. The feasibility of this solution has been analysed in this study. The compounded magnetic flux density B is the sum of the coil's and the iron's flux density. The amount caused by a coil is mainly responsible for the shape of the compounded flux density. Therefore a split of the coil pair was simulated to obtain more possibilities in the adjustment of a lower-energy beam to its ideal isochronous shape. The result is a simulated isochronous 240 MeV beam which was found with an tangential split of the coil pair, their repositioning and the increasing of current in the first coil pair and decreasing in the other one. The tangential split seemed to reduce the problem of the irons linear share of B. This feasibility study is seen as a first step before using 3D-capable software which considers a higher spatial resolution and the influence of temperature.(author)

  8. Medical Care Cost Recovery National Database (MCCR NDB)

    Data.gov (United States)

    Department of Veterans Affairs — The Medical Care Cost Recovery National Database (MCCR NDB) provides a repository of summary Medical Care Collections Fund (MCCF) billing and collection information...

  9. Future cyclotron systems : an industrial perspective

    International Nuclear Information System (INIS)

    Stevenson, N.R.; Dickie, W.J.

    1995-09-01

    The use of commercial cyclotron systems for the production of radioisotopes continues to grow on a world-wide scale. Improvements in technology have significantly increased the production capabilities of modem cyclotron-based isotope production facilities. In particular, the change to negative ion acceleration and new high power systems have resulted in dramatic improvements in reliability, increases in capacity, and decreases in personnel radiation dose. As more and more older machines are retired decisions regarding their replacement are made based on several factors including the market's potential and the cyclotron system's abilities. Taking the case of the recently upgraded TR30 cyclotron at TRIUMF/Nordion, we investigate the requirements industrial/medical users are likely to impose on future commercial cyclotron systems and the impact this will have on cyclotron technology by the end of the century. (author)

  10. Future cyclotron systems: An industrial perspective

    International Nuclear Information System (INIS)

    Stevenson, N.R.; Dickie, W.J.

    1995-09-01

    The use of commercial cyclotron systems for the production of radioisotopes continues to grow on a world-wide scale. Improvements in technology have significantly increased the production capabilities of modern cyclotron-based isotope production facilities. In particular, the change to negative ion acceleration and new high power systems have resulted in dramatic improvements in reliability, increases in capacity, and decreases in personnel radiation dose. As more and more older machines are retired, decisions regarding their replacement are made based on several factors including the market's potential and the cyclotron system's abilities. Taking the case of the recently upgraded TR30 cyclotron at TRIUMF/Nordion, the authors investigate the requirements industrial/medical users are likely to impose on future commercial cyclotron systems and the impact this will have on cyclotron technology by the end of the century

  11. Electromagnetic cyclotron harmonic waves

    International Nuclear Information System (INIS)

    Ohnuma, T.; Watanabe, T.; Hamamatsu, K.

    1981-09-01

    Electromagnetic electron cyclotron harmonic waves just below the electron cyclotron harmonics are investigated numerically and experimentally. Backward waves which are observed to propagate nearly perpendicular to the magnetic field just below the electron cyclotron frequency in a high density magnetoplasma are confirmed to be in accord with the theoretical electromagnetic cyclotron waves. (author)

  12. Trends in cyclotrons for radionuclide production

    International Nuclear Information System (INIS)

    Vera Ruiz, H.; Lambrecht, R.M.

    1999-01-01

    The IAEA recently concluded a worldwide survey of the cyclotrons used for radionuclide production. Most of the institutions responded to the questionnaire. The responses identified technical, utilisation and administrative information for 206 cyclotrons. Compiled data includes the characteristics, performance and popularity of each of the different commercial cyclotrons. Over 20 cyclotrons are scheduled for installation in 1998. The expansion in the number of cyclotron installations during the last decade was driven by the advent of advances in medical imaging instrumentation (namely, positron emission tomography (PET), and more recently by 511 KeV emission tomography); introduction of user friendly compact medical cyclotrons; and recent governmental decisions that permit reimbursement for cyclotron radiopharmaceutical studies by the government or insurance companies. The priorities for the production of clinical, commercial and research radionuclides were identified. The emphasis is on radionuclides used for medical diagnosis with SPET (e.g. 123 I, 201 Tl) and PET (e.g. 11 C, 13 N, 15 O, 18 F) radiopharmaceuticals, and for individualized patient radiation treatment planning (e.g. 64 Cu, 86 Y, 124 I) with PET. There is an emerging trend to advance the cyclotron as an alternative method to nuclear reactors for the production of neutron-rich radionuclides (e.g. 64 Cu, 103 Pd, 186 Re) needed for therapeutic applications. (authors)

  13. An investigation into the technical feasibility of cyclotron production of technetium-99m

    International Nuclear Information System (INIS)

    Egan, G.F.; Lagunas-Solar, M.C.

    1994-01-01

    The role of technetium-99m in nuclear medicine is well established with 80 per cent to 90 per cent of all nuclear medicine studies utilising this isotope. Technetium-99m is currently produced from nuclear reactors via production of the parent radionuclide molybdenum-99. The reactor production of 99m Tc has both significant financial and environmental costs, with unresolved problems in the areas of radioactive waste disposal and reactor decommissioning. Recent scientific publications have indicated that medical quality 99m Tc may be produced using cyclotrons without having the associated problems of waste disposal and decommissioning. Further scientific research is now required to demonstrate the feasibility of this cyclotron production technique. A collaboration between the Cyclotron and PET Centre, Austin Hospital, the National Medical Cyclotron, ANSTO, Sydney, and the Crocker Nuclear Laboratory, University of California, Davis, USA has been proposed. The general objective of the proposed collaboration is to acquire additional scientific data to evaluate the 99m Tc cyclotron production method and to determine the feasibility of cyclotron technology for Australian nuclear medicine. 16 refs., 2 tabs

  14. Advances in superconducting cyclotrons at MSU

    International Nuclear Information System (INIS)

    Blosser, H.; Antaya, T.; Au, R.

    1987-01-01

    Intensive work on superconducting cyclotrons began at MSU in late 1973 (a brief earlier study had occurred in the early 1960's) and continues vigorously at present. One large cyclotron, the ''K500'', has been operating for a number of years, a second, the ''K800'', is nearing completion, the first operating tests of its magnet having occurred at the time of the previous conference, and a third, the ''medical cyclotron'', is now also nearing completion with first operation of its magnet expected just after the present conference. These cyclotrons like other superconducting cyclotrons are all dramatically smaller than comparable room temperature machines; overall weight is typically about 1/20th of that of room temperature cyclotrons of the same energy. This large reduction in the quantities of materials is partially offset by added complexity, but finally, a net overall cost savings of 50 to 70 % typically results; as a consequence the superconducting cyclotron is widely viewed as the cyclotron of the future. The thirteen years of experience at MSU involving three of these cyclotrons, together with much important work at other laboratories, gives a rather clear view of the advantages and disadvantages of various design approaches including by now a rather significant period of long term evaluation. This paper reviews highlights of this program. (author)

  15. JSW's baby cyclotron

    International Nuclear Information System (INIS)

    Toda, Y.; Kaneda, Y.; Satoh, Y.; Suzukawa, I.; Yamada, T.

    1983-01-01

    Designed by The Japan Steel Works, Ltd., specially for installation in a hospital's medical department and nuclear research laboratory, '' JSW BABY CYCLOTRON '' has been developed to produce short-lived radioisotopes such as 11C, 13N, 15O and 18F. JSW's Baby Cyclotron has some design features. 1) Fixed energy and four sector azimuthally varying field. 2) Compact figure desired for hospital's nuclear medical department 3) A bitter type magnet yoke shielding activity 4) Simple control and operation 5) Easy maintenance without skilled personnel. Type BC105 (P:10MeV, d:5MeV), BC107 (P:10MeV, d:7MeV), BC168 (P:16MeV, d:8MeV) and BC1710 (P:17MeV, d:10MeV) are available according to required amount of radioisotopes. In our radioisotope production test, yield and purity of 11C, 13N, 15O and 18F are usable to clinical diagnosis

  16. Cyclotron produced radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kopicka, K.; Fiser, M.; Hradilek, P.; Hanc, P.; Lebeda, O.

    2003-01-01

    Some of the cyclotron-produced radionuclides may serve as important materials for the production of radiopharmaceuticals. This lecture deals with basic information relating to various aspects of these compounds. In comparison with radionuclides /compounds used for non-medical purposes, radiopharmaceuticals are subject to a broader scale of regulations, both from the safety and efficacy point of view; besides that, there are both radioactive and medical aspects that must be taken into account for any radiopharmaceutical. According to the regulations and in compliance with general rules of work with radioactivity, radiopharmaceuticals should only be prepared/manufactured under special conditions, using special areas and special equipment and applying special procedures (e.g. sterilisation, disinfection, aseptic work). Also, there are special procedures for cleaning and maintenance. Sometimes the requirements for the product safety clash with those for the safety of the personnel; several examples of solutions pertaining to these cases are given in the lecture. Also, the specific role of cyclotron radiopharmaceuticals is discussed. (author)

  17. Comparison of short-lived medical isotopes activation by laser thin target induced protons and conventional cyclotron proton beams

    Science.gov (United States)

    Murray, Joseph; Dudnikova, Galina; Liu, Tung-Chang; Papadopoulos, Dennis; Sagdeev, Roald; Su, J. J.; UMD MicroPET Team

    2014-10-01

    Production diagnostic or therapeutic nuclear medicines are either by nuclear reactors or by ion accelerators. In general, diagnostic nuclear radioisotopes have a very short half-life varying from tens of minutes for PET tracers and few hours for SPECT tracers. Thus supplies of PET and SPECT radiotracers are limited by regional production facilities. For example 18F-fluorodeoxyglucose (FDG) is the most desired tracer for positron emission tomography because its 110 minutes half-life is sufficient long for transport from production facilities to nearby users. From nuclear activation to completing image taking must be done within 4 hours. Decentralized production of diagnostic radioisotopes will be idea to make high specific activity radiotracers available to researches and clinicians. 11 C, 13 N, 15 O and 18 F can be produced in the energy range from 10-20 MeV by protons. Protons of energies up to tens of MeV generated by intense laser interacting with hydrogen containing targets have been demonstrated by many groups in the past decade. We use 2D PIC code for proton acceleration, Geant4 Monte Carlo code for nuclei activation to compare the yields and specific activities of short-lived isotopes produced by cyclotron proton beams and laser driven protons.

  18. Recent development and progress of IBA cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Kleeven, W., E-mail: Willem.Kleeven@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Abs, M., E-mail: Michel.Abs@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Delvaux, J.L., E-mail: Jean-Luc.Delvaux@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Forton, E., E-mail: Eric.Forton@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Jongen, Y., E-mail: Yves.Jongen@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Medeiros Romao, L., E-mail: Luis.MedeirosRomao@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Nactergal, B., E-mail: Benoit.Nactergal@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Nuttens, V., E-mail: Vincent.Nuttens@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Servais, T., E-mail: Thomas.Servais@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Vanderlinden, T., E-mail: Thierry.Vanderlinden@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Zaremba, S., E-mail: Simon.Zaremba@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium)

    2011-12-15

    Several cyclotron development projects were recently realized by Ion Beam Applications S.A. (IBA). This contribution presents three of them: (i) the intensity enhancement of the Cyclone 30 cyclotron, a machine mainly used for the production of SPECT isotopes. This project is related with the increased demand for {sup 201}Tl because of the shortage of Mo/Tc generators from nuclear reactors, (ii) development of a new versatile multiple-particle K = 30 isotope-production cyclotron (the Cyclone 30XP) being able to accelerate H{sup -}, D{sup -} and also {alpha}-particles. The {alpha}-beam of this cyclotron will allow the production of new therapeutic isotopes (e.g. {sup 211}At) and (iii) commissioning of the Cyclone 70 cyclotron installed for Arronax in France. This machine is similar to the C30XP but provides higher energy (K = 70) and allows research on new types of medical isotopes.

  19. Present situation of 'baby cyclotron'

    International Nuclear Information System (INIS)

    Yamada, Teruo

    1981-01-01

    A ''baby cyclotron'' has been developed by the Japan Steel Works, Ltd. Its No. 1 model (proton 9.4 MeV) was delivered to the Nakano Hospital of National Sanatorium in March, 1979. It is being used successfully for the production of 11 C, 13 N and 15 O and labeled compounds. The proton or deuteron particles accelerated in the cyclotron collide on target materials. The target box, which is automatically changeable, is directly installed to the accelerating box, thereby taking the safety measures for any leaking radiation. The following matters are described: the production of short-lived radioisotopes (RI yields and treatment); the processes of production in the Nakano Hospital, with No. 1 baby cyclotron, including the photosynthesis of labeled compounds such as 11 C-labeled glucose; the research on the automation in the synthesis of organic labeled compounds like 11 C-palmitic acid. (J.P.N.)

  20. Cyclotron/PET project in Uruguay

    International Nuclear Information System (INIS)

    Engler, H.

    2006-01-01

    The Positron Computed Tomography (PET) is a tri dimensional image technique which shows biochemical information. PET is used in neurology and cardiology diseases. The National Center Cyclotron PET has been found to research, development and health science applications.

  1. Cyclotrons as mass spectrometers

    International Nuclear Information System (INIS)

    Clark, D.J.

    1984-04-01

    The principles and design choices for cyclotrons as mass spectrometers are described. They are illustrated by examples of cyclotrons developed by various groups for this purpose. The use of present high energy cyclotrons for mass spectrometry is also described. 28 references, 12 figures

  2. Cyclotron waves in plasma

    International Nuclear Information System (INIS)

    Lominadse, D.G.

    1975-01-01

    The book deals with fundamental physical concepts of the theory of cyclotron waves and cyclotron instabilities conditioned by the presence in plasma of direct or alternating electric currents passing in it perpendicularily to a magnetic field. A great variety of problems is considered connected with the linear theory of cyclotron oscillations in equilibrium and electron plasma of metals and semiconductors. Parametric excitations of electron cyclotron oscillations of plasma in an alternating electric field are studied. Particular attention is paid to the investigation of plasma turbulence arising as a result of development of cyclotron instabilities. Experimental data are discussed and compared with theoretical results

  3. Cyclotron waves in plasma

    CERN Document Server

    Lominadze, D G

    2013-01-01

    Cyclotron Waves in Plasma is a four-chapter text that covers the basic physical concepts of the theory of cyclotron waves and cyclotron instabilities, brought about by the existence of steady or alternating plasma currents flowing perpendicular to the magnetic field.This book considers first a wide range of questions associated with the linear theory of cyclotron oscillations in equilibrium plasmas and in electron plasmas in metals and semiconductors. The next chapter deals with the parametric excitation of electron cyclotron oscillations in plasma in an alternating electric field. A chapter f

  4. Theoretical estimation of "6"4Cu production with neutrons emitted during "1"8F production with a 30 MeV medical cyclotron

    International Nuclear Information System (INIS)

    Auditore, Lucrezia; Amato, Ernesto; Baldari, Sergio

    2017-01-01

    Purpose: This work presents the theoretical estimation of a combined production of "1"8F and "6"4Cu isotopes for PET applications. "6"4Cu production is induced in a secondary target by neutrons emitted during a routine "1"8F production with a 30 MeV cyclotron: protons are used to produce "1"8F by means of the "1"8O(p,n)"1"8F reaction on a ["1"8O]-H_2O target (primary target) and the emitted neutrons are used to produce "6"4Cu by means of the "6"4Zn(n,p)"6"4Cu reaction on enriched zinc target (secondary target). Methods: Monte Carlo simulations were carried out using Monte Carlo N Particle eXtended (MCNPX) code to evaluate flux and energy spectra of neutrons produced in the primary (Be+["1"8O]-H_2O) target by protons and the attenuation of neutron flux in the secondary target. "6"4Cu yield was estimated using an analytical approach based on both TENDL-2015 data library and experimental data selected from EXFOR database. Results: Theoretical evaluations indicate that about 3.8 MBq/μA of "6"4Cu can be obtained as a secondary, ‘side’ production with a 30 MeV cyclotron, for 2 h of irradiation of a proper designed zinc target. Irradiating for 2 h with a proton current of 120 μA, a yield of about 457 MBq is expected. Moreover, the most relevant contaminants result to be "6"3","6"5Zn, which can be chemically separated from "6"4Cu contrarily to what happens with proton irradiation of an enriched "6"4Ni target, which provides "6"4Cu mixed to other copper isotopes as contaminants. Conclusions: The theoretical study discussed in this paper evaluates the potential of the combined production of "1"8F and "6"4Cu for medical purposes, irradiating a properly designed target with 30 MeV protons. Interesting yields of "6"4Cu are obtainable and the estimation of contaminants in the irradiated zinc target is discussed. - Highlights: • "6"4Cu production with secondary neutrons from "1"8F production with protons was investigated. • Neutron reactions induced in enriched "6"4Zn

  5. PIXE analysis by baby cyclotron

    International Nuclear Information System (INIS)

    Yoshida, Hyogo; Tanaka, Teruaki; Ito, Takashi; Toda, Yohjiro; Wakasa, Hideichiro

    1988-01-01

    The Japan Steel Works, Ltd. has been supplying a very small sized cyclotron (Baby Cyclotron) to hospitals and research facilities. The cyclotron is designed to produce short-lived radioisotopes for medical use. In the present study, this cyclotron is modified so that it can serve for PIXE analysis. The PIXE (particle induced X-ray emission) technique has the following features: (1) Down to 1 ng of trace material in a sample (mg - μg) can be detected, (2) An analysis run is completed in one to ten minutes, permitting economical analysis for a large number of samples, (3) Several elements can be analyzed simultaneously, with an almost constant sensitivity for a variety of elements ranging from aluminum to heavy metals, (4) Analysis can be performed nondestructively without a chemical process, and (5) The use of microbeam can provide data on the distribution of elements with a resolution of several μm. Software for analysis is developed to allow the modified equipment to perform peak search, background fitting, and identification and determination of peaks. A study is now being conducted to examine the performance of the equipment for PIXE analysis of thin samples. Satisfactory results have been obtained. The analysis time, excluding the background correction, is 5-10 min. (Nogami, K.)

  6. Patient Workload Profile: National Naval Medical Center (NNMC), Bethesda, MD.

    Science.gov (United States)

    1980-06-01

    AD-A09a 729 WESTEC SERVICES NC SAN DIEGOCA0S / PATIENT WORKLOAD PROFILE: NATIONAL NAVAL MEDICAL CENTER NNMC),- ETC(U) JUN 80 W T RASMUSSEN, H W...provides site workload data for the National Naval Medical Center (NNMC) within the following functional support areas: Patient Appointment...on managing medical and patient data, thereby offering the health care provider and administrator more powerful capabilities in dealing with and

  7. Directory of cyclotrons used for radionuclide production in Member States

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The directory of cyclotrons used for radionuclide production is an update of the data base on cyclotrons that was compiled in 1983 by the International Atomic Energy Agency. The directory contains technical, utilization and administrative information supplied to the IAEA as of October 1997. The directory was prepared through information collected by questionnaires sent to institutions that either have a cyclotron, or that were identified to be in the process of installation of a cyclotron. The directory contains 206 entries for cyclotrons operating in 34 Member States. The largest concentration of cyclotrons for radionuclide production are located in the United States of America (66), Japan (33) and Germany (22). The largest number of cyclotrons for a single country is the United States of America. The expansion in number of cyclotrons during the last decade has been driven by the advent of advances in medical imaging instrumentation (PET, SPET and more recently 511 KeV emission tomography); introduction of user friendly compact medical cyclotrons from several companies that manufacture cyclotrons; and recent decisions that {sup 15}O-oxygen PET studies in Japan, and {sup 18}F-FDG PET studies in Germany are eligible for reimbursement by government or insurance companies.

  8. Directory of cyclotrons used for radionuclide production in Member States

    International Nuclear Information System (INIS)

    1998-03-01

    The directory of cyclotrons used for radionuclide production is an update of the data base on cyclotrons that was compiled in 1983 by the International Atomic Energy Agency. The directory contains technical, utilization and administrative information supplied to the IAEA as of October 1997. The directory was prepared through information collected by questionnaires sent to institutions that either have a cyclotron, or that were identified to be in the process of installation of a cyclotron. The directory contains 206 entries for cyclotrons operating in 34 Member States. The largest concentration of cyclotrons for radionuclide production are located in the United States of America (66), Japan (33) and Germany (22). The largest number of cyclotrons for a single country is the United States of America. The expansion in number of cyclotrons during the last decade has been driven by the advent of advances in medical imaging instrumentation (PET, SPET and more recently 511 KeV emission tomography); introduction of user friendly compact medical cyclotrons from several companies that manufacture cyclotrons; and recent decisions that 15 O-oxygen PET studies in Japan, and 18 F-FDG PET studies in Germany are eligible for reimbursement by government or insurance companies

  9. National Medical Terminology Server in Korea

    Science.gov (United States)

    Lee, Sungin; Song, Seung-Jae; Koh, Soonjeong; Lee, Soo Kyoung; Kim, Hong-Gee

    Interoperable EHR (Electronic Health Record) necessitates at least the use of standardized medical terminologies. This paper describes a medical terminology server, LexCare Suite, which houses terminology management applications, such as a terminology editor, and a terminology repository populated with international standard terminology systems such as Systematized Nomenclature of Medicine (SNOMED). The server is to satisfy the needs of quality terminology systems to local primary to tertiary hospitals. Our partner general hospitals have used the server to test its applicability. This paper describes the server and the results of the applicability test.

  10. MICHIGAN: Cyclotron conference

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    A sense of excitement was in the air as cyclotron physicists and engineers from 17 countries convened on 30 April for the opening of the Tenth International Conference on Cyclotrons and Their Applications. Some 50 years after its invention, the redoubtable cyclotron remains a topic of compelling current interest. Cyclotron experts gathered at Michigan State University's Kellogg Center to hear of latest developments, of progress and successes on new machines which had come into operation, of new projects which were underway, and of dreams which lay ahead

  11. MICHIGAN: Cyclotron conference

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1984-10-15

    A sense of excitement was in the air as cyclotron physicists and engineers from 17 countries convened on 30 April for the opening of the Tenth International Conference on Cyclotrons and Their Applications. Some 50 years after its invention, the redoubtable cyclotron remains a topic of compelling current interest. Cyclotron experts gathered at Michigan State University's Kellogg Center to hear of latest developments, of progress and successes on new machines which had come into operation, of new projects which were underway, and of dreams which lay ahead.

  12. [Cyclotron based nuclear science

    International Nuclear Information System (INIS)

    1989-06-01

    This report contains papers on the following topics: Heavy ion reactors, nuclear structure and fundamental interactions; atomic and materials studies; nuclear theory; and superconducting cyclotron and instrumentation

  13. Production, administration and disposal of cyclotron produced shortlived radioactive gases for positron emission tomography studies at the Austin Repatriation Medical Centre, Melbourne

    Energy Technology Data Exchange (ETDEWEB)

    Egan, G.F.; O`Keefe, G. [Austin Hospital, Heidelberg, VIC (Australia); Tochon-Danguy, H.J.; Midgley, S.; Phana, K.S.; Sachinidis, J.; Chan, J.G. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1995-01-01

    Positron Emission Tomography (PET) Centre is operational at the Austin Repatriation Medical Centre, Melbourne. The major equipment consists of a 10 MeV cyclotron and a whole body PET scanner. Radioactive gases produced and used directly in clinical studies include [{sup 15}O]O{sub 2}, [{sup 15}O]CO, and [{sup 15}O]CO{sub 2}, whilst [{sup 11}C]CO{sub 2} is also produced for use in radiochemistry syntheses. Radioactivity delivery rates of 3.7, 3.3, and 1.6 GBq/min to the scanner suite have been achieved for [{sup 15}O]O{sub 2}, [{sup 15}O]CO{sub 2}, and [{sup 15}O]CO respectively, and batch productions of 36.3 GBq of [{sup 11}C]CO{sub 2} have been produced. The production. patient administration and disposal of the short-lived radioactive gases has been achieved in compliance with radiation protection principles. Radioactive gas doses of 1.7 GBq are administered to patients with less than 0.02 MBq/m{sup 3} leakage into the scanner suite. Less than 13 MBq of [ {sup 15}O]-labelled gases are released into the environment per patient study at a concentration of 0.018 MBq/m{sup 3}. Annually less than 2 GBq is expected to be released into the environment. The centre design and first four months` experience of radioactive gas production, administration and disposal is presented. 5 refs., 4 tab., 1 fig.

  14. 20 years Rossendorf cyclotron

    International Nuclear Information System (INIS)

    1978-08-01

    On the occasion of the 20th anniversary of initiating of the Rossendorf cyclotron accounts are given of most important works and results in the field of accelerator engineering and utilization of this machine. The reports show the trend of development and actual spectrum of application. The enclosed literature lists give a survey of technical and experimental works at cyclotron. (author)

  15. The problems of high efficient extraction from the isochronous cyclotron

    International Nuclear Information System (INIS)

    Schwabe, J.

    1994-06-01

    The problem of high efficient extraction (η ≥ 50%) from isochronous cyclotrons (with the exception of the stripping method) is not completely solved up to this day. This problem is specifically important, because these cyclotrons are being also applied in the production of medical radioisotopes, labeled pharmaceuticals as well as in neutron therapy (oncology), machine industry, agriculture (plant mutagenesis), etc. The aim of the proposed topic is to solve this problem on the AIC-144 isochronous cyclotron in the INP (Institute of Nuclear Physics). Lately, a beam of 20 MeV deuterons with an efficiency of ca. 15% was extracted from this cyclotron. (author). 25 refs, 14 figs

  16. Diagnostic system for the nuclear medicine with baby cyclotron

    International Nuclear Information System (INIS)

    Kashihara, Masao; Wakasa, Shyuichiro

    1982-01-01

    The system of cyclotron nuclear medicine consists of ''RI-production by using the cyclotron'', ''production of radio-pharmaceuticals labeled with RI'', ''positron tomography''. On the other hand, Ultra compact cyclotron (Baby cyclotron) itself, RI production technique and positron tomography have been rapidly developed and advanced. We think that these three functions must be balance in the development in order to spread this system into the routine work in the hospital. However, since the technology of the synthesis for the labeled compounds is not so developed so far, more advance can be strongly expected. In this report, construction of the cyclotron nuclear medicine, utility for the practical use of RI produced by using the cyclotron, technique of RI production, and the studies on automated and efficient productions of radio-pharmaceuticals labeled with short-lived positron emitters for medical diagnostic use are described. (author)

  17. Vancouver Cyclotron Conference

    International Nuclear Information System (INIS)

    Clark, David J.

    1993-01-01

    Although no longer on the high energy frontier, the cyclotron field is still a major scientific growth area. Its progress is highlighted at the international conference on cyclotron design, development and utilization held at intervals of about three years, under the auspices of the International Union of Pure and Applied Physics (IUPAP). Vancouver, surrounded by mountains, water and some cyclotrons, provided a pleasant setting for the 13th Conference, held last summer. With over 200 cyclotrons in operation around the world, the attendance, 241 delegates and 26 industrial exhibitors, was a near record, reflecting the flourishing state of the field. The early sessions covered the initial operation of new or upgraded cyclotron facilities. Major facilities completed since the previous Conference in Berlin in May 1989 included the 400 MeV ring cyclotron at Osaka, the U400M cyclotron at Dubna which will be coupled to the U400 to give 20 MeV nucléon uranium beams, the 130 MeV cyclotron at Jyvaskyla (in Finland, the furthest north!), the 110 MeV JAERI machine in Japan, and the 65 MeV proton therapy cyclotron in Nice. Among the facility upgrades were the KFA cyclotron at Julich which will inject the 2.5 GeV storage ring COSY, and the addition of an FM mode to the K=200 CW mode at Uppsala to give protons up to 180 MeV. The impressive current of 1.5 mA at 72 MeV obtained from the PSI Injector II will soon be injected into the 590 MeV ring

  18. Development of cyclotron solid targetry

    International Nuclear Information System (INIS)

    D'Souza, J.; Deans, T.; Cryer, D.; Price, R.

    2004-01-01

    Full text: Western Australia's first medical cyclotron was recently installed in the Department of Medical Technology and Physics at Sir Charles Gairdner Hospital. The cyclotron is routinely used for 18 F production using a liquid target, and now research is being undertaken into solid target bombardment for production of novel isotopes such as 124 I, 64 Cu and 96 Tc. The IBA Cyclone 18/9 has a maximum proton beam energy of 18MeV and maximum beam current of 80μA. A proton beam is generated by the acceleration of H- ions in the evacuated cyclotron (10 -6 bar) which are then stripped of 2 electrons just prior to exiting a target port. Each port has two strippers which are made of 10μm thick carbon with dimensions 12mmxl3mm. Due to their thinness, the strippers are easily ruptured. The Cyclone 18/9 has 8 target ports. In order to fit a target onto the cyclotron when the cyclotron is already evacuated the target is first evacuated to 10 -3 bar by a roughing pump before an isolation valve at the port is opened. This stops any damage that may occur by the flow of air from the target reservoir to the cyclotron eg to the strippers. The first step in the project to develop solid targetry is to build a beam line in order to measure the beam profile. If successful, this design will be improved in order to have a beam line and target holder that are suitable for use in solid target bombardment. A 40cm beam line with an internal diameter of 3.6cm was built to fit onto the IBA Cyclone 18/9. The beam line, made out of aluminium, incorporates a step 5cm from the end at which a target material can be fitted. A cover fits onto the beam line, behind the target in order to maintain vacuum. The cover is held in place by the vacuum within the beam line. At the end of bombardment, the beam line can be isolated from the vacuum of the target and normal air pressure restored. In doing so the cover plate falls open and the target falls into a lead pot, ready for removal from the cyclotron

  19. Cyclotrons at the Institute of Physical and Chemical Research

    International Nuclear Information System (INIS)

    Imamura, Masashi.

    1989-01-01

    In this article the destruction by American forces, during World War II, of the Japanese cyclotrons and the subsequent construction of new cyclotrons at the Institute of Physical and Chemical Research, Japan is described. Their use for biological and medical radiation chemistry studies is summarized. (UK)

  20. 78 FR 45917 - National Committee on Foreign Medical Education and Accreditation Meeting

    Science.gov (United States)

    2013-07-30

    ... DEPARTMENT OF EDUCATION National Committee on Foreign Medical Education and Accreditation Meeting AGENCY: Office of Postsecondary Education, National Committee on Foreign Medical Education and... meeting of the National Committee on Foreign Medical Education and Accreditation (NCFMEA). Parts of this...

  1. The historic and national aspects of medical ethics and deontology.

    Directory of Open Access Journals (Sweden)

    Prikhoda Igor' Viktorovich

    2009-02-01

    Full Text Available Researches of problems of medical ethics and deontology in activity of the medical worker presented. Historical and national aspects of the delivered problem are considered. They open diversity and complexity of realization of problems of formation of the person of the medical worker. The humanism in medicine makes its ethical basis and morals. The humanism serves moral development of the person of the medical worker. Without humanism the medicine loses the right on existence. Its scientific and professional principles conflict to its basic purpose - to serve the person.

  2. Weak effect of ion cyclotron acceleration on rapidly chirping beam-driven instabilities in the National Spherical Torus Experiment

    International Nuclear Information System (INIS)

    Heidbrink, W W; Ruskov, E; Fredrickson, E D; Gorelenkov, N; Medley, S S; Berk, H L; Harvey, R W

    2006-01-01

    The fast-ion distribution function in the National Spherical Torus Experiment is modified from shot to shot while keeping the total injected power at ∼2 MW. Deuterium beams of different energy and tangency radius are injected into helium L-mode plasmas, producing a rich set of instabilities, including compressional Alfven eigenmodes, toroidicity-induced Alfven eigenmodes (TAE), 50-100 kHz instabilities with rapid frequency sweeps or chirps, and strong, low frequency (10-20 kHz) fishbones. The experiment was motivated by a theory that attributes frequency chirping to the formation of holes and clumps in phase-space. In the theory, increasing the effective collision frequency of the fast ions that drive the instability can suppress frequency chirping. In the experiment, high-power (∼<3 MW) high harmonic fast wave (HHFW) heating accelerates the fast ions in an attempt to alter the nonlinear dynamics. Steady-frequency TAE modes diminish during the HHFW heating but there is little evidence that frequency chirping is suppressed

  3. Weak effect of ion cyclotron acceleration on rapidly chirping beam-driven instabilities in the National Spherical Torus Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Heidbrink, W W [University of California, Irvine, California (United States); Ruskov, E [University of California, Irvine, California (United States); Fredrickson, E D [Princeton Plasma Physics Laboratory, Princeton, New Jersey (United States); Gorelenkov, N [Princeton Plasma Physics Laboratory, Princeton, New Jersey (United States); Medley, S S [Princeton Plasma Physics Laboratory, Princeton, New Jersey (United States); Berk, H L [University of Texas, Austin, Texas (United States); Harvey, R W [CompX, Del Mar, California (United States)

    2006-09-15

    The fast-ion distribution function in the National Spherical Torus Experiment is modified from shot to shot while keeping the total injected power at {approx}2 MW. Deuterium beams of different energy and tangency radius are injected into helium L-mode plasmas, producing a rich set of instabilities, including compressional Alfven eigenmodes, toroidicity-induced Alfven eigenmodes (TAE), 50-100 kHz instabilities with rapid frequency sweeps or chirps, and strong, low frequency (10-20 kHz) fishbones. The experiment was motivated by a theory that attributes frequency chirping to the formation of holes and clumps in phase-space. In the theory, increasing the effective collision frequency of the fast ions that drive the instability can suppress frequency chirping. In the experiment, high-power ({approx}<3 MW) high harmonic fast wave (HHFW) heating accelerates the fast ions in an attempt to alter the nonlinear dynamics. Steady-frequency TAE modes diminish during the HHFW heating but there is little evidence that frequency chirping is suppressed.

  4. Weak effect of ion cyclotron acceleration on rapidly chirping beam-driven instabilities in the National Spherical Torus Experiment

    Energy Technology Data Exchange (ETDEWEB)

    W W,Heidbrink; E,Ruskov; E D,Fredrickson; N,Gorelenkov; S S,Medley; H L,Berk; R W,Harvey

    2006-09-01

    The fast-ion distribution function in the National Spherical Torus Experiment is modified from shot to shot while keeping the total injected power at ~2 MW. Deuterium beams of different energy and tangency radius are injected into helium L-mode plasmas, producing a rich set of instabilities, including compressional Alfven eigenmodes, toroidicity-induced Alfven eigenmodes (TAE), 50–100 kHz instabilities with rapid frequency sweeps or chirps, and strong, low frequency (10–20 kHz) fishbones. The experiment was motivated by a theory that attributes frequency chirping to the formation of holes and clumps in phase-space. In the theory, increasing the effective collision frequency of the fast ions that drive the instability can suppress frequency chirping. In the experiment, high-power (≤3MW) high harmonic fast wave (HHFW) heating accelerates the fast ions in an attempt to alter the nonlinear dynamics. Steady-frequency TAE modes diminish during the HHFW heating but there is little evidence that frequency chirping is suppressed.

  5. Manufacturing on the radiopharmaceuticals produced by cyclotron

    International Nuclear Information System (INIS)

    Ueda, Nobuo

    1994-01-01

    Radiopharmaceutical (RP) produced by cyclotrons are widely used for the in vivo diagnosis of various diseases such as cancer, cerebral vascular disorders and cardiac diseases. The nuclides used as RPs and their nuclear reactions, and the quantity of RPs supplied in Japan in the last five years are shown. These RPs are delivered to about 1,100 hospitals in Japan. Thallium-201 and iodine-123 showed very high growth rate. Recently, two new I-123 RPs, BMIPP and MIBG which are heart-imaging agents, have been supplied. It suggests that the quantity of I-123 will increase much more in future. The image diagnostic method using RPs is called in vivo nuclear medicine, and has become the indispensable means for medical institutions together with X-ray CT, nuclear magnetic resonance imaging and ultrasonic diagnosis. The RPs for in vivo diagnosis generally used at present are classified into those labeled with the RIs produced with cyclotrons and those labeled with Tc-99m formed by the decay of Mo-99. The quantity being used is overwhelmingly more in the latter, but the former shows the tendency of growth. The commercial production of cyclotron RIs for medical use, the chemical forms and the diagnostic purposes of the RPs using cyclotron RIs, and the state of use of the cyclotron-produced RPs are reported. (K.I.)

  6. New superconducting cyclotron driven scanning proton therapy systems

    International Nuclear Information System (INIS)

    Klein, Hans-Udo; Baumgarten, Christian; Geisler, Andreas; Heese, Juergen; Hobl, Achim; Krischel, Detlef; Schillo, Michael; Schmidt, Stefan; Timmer, Jan

    2005-01-01

    Since one and a half decades ACCEL is investing in development and engineering of state of the art particle-therapy systems. A new medical superconducting 250 MeV proton cyclotron with special focus on the present and future beam requirements of fast scanning treatment systems has been designed. The first new ACCEL medical proton cyclotron is under commissioning at PSI for their PROSCAN proton therapy facility having undergone successful factory tests especially of the closed loop cryomagnetic system. The second cyclotron is part of ACCEL's integrated proton therapy system for Europe's first clinical center, RPTC in Munich. The cyclotron, the energy selection system, the beamline as well as the four gantries and patient positioners have been installed. The scanning system and major parts of the control software have already been tested. We will report on the concept of ACCEL's superconducting cyclotron driven scanning proton therapy systems and the current status of the commissioning work at PSI and RPTC

  7. Medical students call for national standards in anatomical education.

    Science.gov (United States)

    Farey, John E; Sandeford, Jonathan C; Evans-McKendry, Greg D

    2014-11-01

    The diminishing number of hours dedicated to formal instruction in anatomy has led to a debate within medical education as to the level required for safe clinical practice. We provide a review of the current state of anatomical education in Australian medical schools and state the case for national standards. In light of the review presented, council members of the Australian Medical Students' Association voted to affirm that consideration should be given to developing undergraduate learning goals for anatomy, providing a codified medical student position on the teaching of anatomy in Australian medical schools. Crucially, the position states that time-intensive methods of instruction such as dissection should be a rite of passage for medical students in the absence of evidence demonstrating the superiority of modern teaching methods. We believe the bodies with a vested interest in the quality of medical graduates, namely the Australian Medical Council, Medical Deans Australia & New Zealand, and the postgraduate colleges should collaborate and develop clear guidelines that make explicit the core knowledge of anatomy expected of medical graduates at each stage of their career with a view to safe clinical practice. In addition, Australian universities have a role to play in conducting further research into contemporary learning styles and the most efficacious methods of delivering anatomical education. © 2014 Royal Australasian College of Surgeons.

  8. Cyclotrons for isotope production

    International Nuclear Information System (INIS)

    Milton, B.F.; Stevenson, N.R.

    1995-06-01

    Cyclotrons continue to be efficient accelerators for radioisotope production. In recent years, developments in the accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicates a strong future for commercial cyclotrons. In this paper we will survey recent developments in the areas of cyclotron technology, and isotope production, as they relate to the new generation of commercial cyclotrons. We will also discuss the possibility of systems capable of extracted energies up to 100 MeV and extracted beam currents of up to 2.0 mA. (author). 6 refs., 2 tabs., 3 figs

  9. Synchro-cyclotron

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    The electromagnetic coil which forms the first section of the proton extraction channel in the improved synchro-cyclotron. The photograph shows the positioning gear and the current septum. An extraction efficiency above 50% is expected.

  10. Development of national competency-based learning objectives "Medical Informatics" for undergraduate medical education.

    Science.gov (United States)

    Röhrig, R; Stausberg, J; Dugas, M

    2013-01-01

    The aim of this project is to develop a catalogue of competency-based learning objectives "Medical Informatics" for undergraduate medical education (abbreviated NKLM-MI in German). The development followed a multi-level annotation and consensus process. For each learning objective a reason why a physician needs this competence was required. In addition, each objective was categorized according to the competence context (A = covered by medical informatics, B = core subject of medical informatics, C = optional subject of medical informatics), the competence level (1 = referenced knowledge, 2 = applied knowledge, 3 = routine knowledge) and a CanMEDS competence role (medical expert, communicator, collaborator, manager, health advocate, professional, scholar). Overall 42 objectives in seven areas (medical documentation and information processing, medical classifications and terminologies, information systems in healthcare, health telematics and telemedicine, data protection and security, access to medical knowledge and medical signal-/image processing) were identified, defined and consented. With the NKLM-MI the competences in the field of medical informatics vital to a first year resident physician are identified, defined and operationalized. These competencies are consistent with the recommendations of the International Medical Informatics Association (IMIA). The NKLM-MI will be submitted to the National Competence-Based Learning Objectives for Undergraduate Medical Education. The next step is implementation of these objectives by the faculties.

  11. Vichy France and the continuity of medical nationalism.

    Science.gov (United States)

    Evleth, D

    1995-04-01

    This paper reviews the rise of medical nationalism and protectionism in France from the end of the nineteenth century through to the 1940s, with an emphasis on the Vichy period. It presents this nationalism as part of a continuity, showing its beginnings well before the coming of the Vichy government, its extremes under this government, and its continuation after the fall of the Vichy government, although retreating from its more extreme positions.

  12. National synchrotron light source medical personnel protection interlock

    International Nuclear Information System (INIS)

    Buda, S.; Gmur, N.F.; Larson, R.; Thomlinson, W.

    1998-01-01

    This report is founded on reports written in April 1987 by Robert Hettel for angiography operations at the Stanford Synchrotron Research Laboratory (SSRL) and a subsequent report covering angiography operations at the National Synchrotron Light Source (NSLS); BNL Informal Report 47681, June 1992. The latter report has now been rewritten in order to accurately reflect the design and installation of a new medical safety system at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). Known originally as the Angiography Personnel Protection Interlock (APPI), this system has been modified to incorporate other medical imaging research programs on the same beamline and thus the name has been changed to the more generic Medical Personnel Protection Interlock (MPPI). This report will deal almost exclusively with the human imaging (angiography, bronchography, mammography) aspects of the safety system, but will briefly explain the modular aspects of the system allowing other medical experiments to be incorporated

  13. NATIONAL SYNCHROTRON LIGHT SOURCE MEDICAL PERSONNEL PROTECTION INTERLOCK

    Energy Technology Data Exchange (ETDEWEB)

    BUDA,S.; GMUR,N.F.; LARSON,R.; THOMLINSON,W.

    1998-11-03

    This report is founded on reports written in April 1987 by Robert Hettel for angiography operations at the Stanford Synchrotron Research Laboratory (SSRL) and a subsequent report covering angiography operations at the National Synchrotron Light Source (NSLS); BNL Informal Report 47681, June 1992. The latter report has now been rewritten in order to accurately reflect the design and installation of a new medical safety system at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). Known originally as the Angiography Personnel Protection Interlock (APPI), this system has been modified to incorporate other medical imaging research programs on the same beamline and thus the name has been changed to the more generic Medical Personnel Protection Interlock (MPPI). This report will deal almost exclusively with the human imaging (angiography, bronchography, mammography) aspects of the safety system, but will briefly explain the modular aspects of the system allowing other medical experiments to be incorporated.

  14. 77 FR 24103 - National Registry of Certified Medical Examiners

    Science.gov (United States)

    2012-04-20

    ... competence through periodic training and testing. Following establishment of the National Registry and a... they can determine effectively whether a CMV driver's medical fitness for duty meets FMCSA's standards... understanding of those standards, and maintain and demonstrate competence through periodic training and testing...

  15. Flexible Training Strategy (National Task Force on Medical Staffing)

    OpenAIRE

    Department of Health (Ireland)

    2003-01-01

    Flexible Training Strategy (National Task Force on Medical Staffing) The Flexible Training Strategy, while endorsing flexible/part-time options recognises that the preferred option for the majority of doctors-in-training and consultants is most likely to continue to be full-time training and work. Click here to download PDF

  16. Phases to face in national medical leadership development

    NARCIS (Netherlands)

    Keijser, Wouter Alexander; Wilderom, Celeste P.M.; Poorthuis, Max Bastiaan; Tweedie, Judith; Lees, Peter; Dickson, Graham

    2017-01-01

    Increasing economic and organizational challenges call physicians in action to engage in medical leadership (ML) roles. Yet, in only six of the 195 countries the content of ML development has recently been articulated in the form of comprehensive national schemes or programs. Despite increasing

  17. Decommissioning analyzis of a university cyclotron

    International Nuclear Information System (INIS)

    Eggermont, G.X.; Buls, N.; Hermanne, A.

    1996-01-01

    In the widespread use of some medical nuclear facilities, such as cyclotrons for isotope production, Life cycle analyzis, including decommissioning, was not taken into account. The structural materials of an accelerator and the concrete shielding of the bunker are activated by neutrons. This could yield a considerable volume of nuclear waste and needs radiation protection concern for occupational workers and the environment during some decennia. At the university of Brussels (WB) a prospective radiation protection and waste analyzis is being made for the later decommissioning of their cyclotron. Only few similar studies have been published. In Belgium future nuclear dismantling operations will be submitted to a radiation protection authorization procedure. Meanwhile the nuclear waste authorities insist on dismantling planning, including financial provisioning. An optimization exercise was made at the VUB-cyclotron, taking into account international trends to clearance levels for low level nuclear waste. Conceptual prevention opportunities e.g. selective material choice could be identified for future accelerator constructions. (author)

  18. Neutron radiography by using JSW baby cyclotron

    International Nuclear Information System (INIS)

    Toda, Yojiro

    1995-01-01

    At present, JSW baby cyclotrons are mostly used for the production of the radioisotopes for medical use. The attempt to use this baby cyclotron for neutron radiography began already in 1981. The feasibility of the neutron radiography for the explosives in metallic cases which are used for H1 rockets was investigated. In 1983, it was shown that the neutron radiography by using the baby cyclotron in Muroran Works, Japan Steel Works, Ltd. was able to be carried out as a routine work. Since then, the nondestructive inspection by neutron radiography has been performed for rocket pyrotechnic articles, and contributed to heighten their reliability. Further, the radiography by using fast neutrons was developed and put to practical use for recent large H2 rockets. The JSW baby cyclotron BC 168 which has been used for neutron radiography can accelerate 16 MeV protons or 8 MeV deuterons up to 50 μA. The principle of thermal neutron radiography is the generation of fast neutrons by irradiating a Be target with the proton beam accelerated by a baby cyclotron, the moderation of the fast neutrons, the formation of the thermal neutron flux of uniform distribution with a collimator, the thermal neutron flux hitting the Gd plate in a film cassette through an object, and the exposure of an X-ray film to electrons from the Gd plate. Fast neutron radiography apparatus, and commercial neutron radiography are described. (K.I.)

  19. A National Medical Information System for Senegal: Architecture and Services.

    Science.gov (United States)

    Camara, Gaoussou; Diallo, Al Hassim; Lo, Moussa; Tendeng, Jacques-Noël; Lo, Seynabou

    2016-01-01

    In Senegal, great amounts of data are daily generated by medical activities such as consultation, hospitalization, blood test, x-ray, birth, death, etc. These data are still recorded in register, printed images, audios and movies which are manually processed. However, some medical organizations have their own software for non-standardized patient record management, appointment, wages, etc. without any possibility of sharing these data or communicating with other medical structures. This leads to lots of limitations in reusing or sharing these data because of their possible structural and semantic heterogeneity. To overcome these problems we have proposed a National Medical Information System for Senegal (SIMENS). As an integrated platform, SIMENS provides an EHR system that supports healthcare activities, a mobile version and a web portal. The SIMENS architecture proposes also a data and application integration services for supporting interoperability and decision making.

  20. Ernest Orlando Lawrence (1901-1958), Cyclotron and Medicine

    Energy Technology Data Exchange (ETDEWEB)

    Chu, William T.

    2005-09-01

    On August 8, 2001, Lawrence Berkeley National Laboratory celebrated the centennial of the birth of its founder (and namesake), Ernest Orlando Lawrence. For the occasion, many speeches were given and old speeches were remembered. We recall the words of the late Luis Alvarez, a Nobel Laureate and one of the Lawrence's closest colleagues: ''Lawrence will always be remembered as the inventor of the cyclotron, but more importantly, he should be remembered as the inventor of the modern way of doing science''. J. L. Heilbron and R. W. Seidel, in the introduction of their book, ''Lawrence and His Laboratory'' stated, ''The motives and mechanisms that shaped the growth of the Laboratory helped to force deep changes in the scientific estate and in the wider society. In the entrepreneurship of its founder, Ernest Orlando Lawrence, these motives, mechanisms, and changes came together in a tight focus. He mobilized great and small philanthropists, state and local governments, corporations, and plutocrats, volunteers and virtuosos. The work they supported, from astrophysics and atomic bombs, from radiochemistry to nuclear medicine, shaped the way we observe, control, and manipulate our environment.'' Indeed, all over the civilized world, the ways we do science changed forever after Lawrence built his famed Radiation Laboratory. In this editorial, we epitomize his legacy of changing the way we do medicine, thereby affecting the health and well being of all humanity. This year marks the 75th anniversary of the invention of the cyclotron by Ernest Orlando Lawrence at the University of California at Berkeley. Lawrence conceived the idea of the cyclotron early in 1929 after reading an article by Rolf Wideroe on high-energy accelerators. In the spring of 1930 one of his students, Nels Edlefsen, constructed two crude models of a cyclotron. Later in the fall of the same year, another student, M. Stanley Livingston

  1. Survey on radionuclide producing using cyclotron method in Malaysia

    International Nuclear Information System (INIS)

    Mohd Fadli Mohammad Noh

    2008-01-01

    This research discuss about basic design and systems of medical cyclotron that Malaysia currently have, its applications in radionuclide production and upcoming technologies of cyclotron. Surveys have been carried out on cyclotron facilities at Hospital Putrajaya and Wijaya International Medical Center, WIMC as well as reactor facility at Malaysia Nuclear Agency. The sources in this research also involves on-line and library searches. Information obtained are recorded, categorized, synthesized and discussed. systems of cyclotron of Hospital Putrajaya are further discussed in details. Based from the surveys carried out, it is found out that cyclotron facilities both in Hospital Putrajaya and WIMC only produce ( 18 F)FDG with radioactivity of 18 F produced in 2007 are 16479 mCi and 92546 mCi respectively. Survey also revealed that radioisotope production at Nuclear Malaysia has had its operation been ceased. A new radiopharmaceutical, namely CHOL is suggested to be synthesized by both facilities as a new PET tracer. Latest developments concerning technologies of cyclotron as well as other accelerators such as laser for future medical accelerator, prospect of boron neutron capture and the potential of hadron therapy in Malaysia are discussed here. Radioisotope production in Malaysia is expected to keep booming in future due to increase in usage of PET techniques and the construction of more compact, easy to handle and less costly cyclotrons. (author)

  2. Cyclotron production of high-purity 123I for medical applications via the 127I(p,5n)123Xe → 123I nuclear reaction

    International Nuclear Information System (INIS)

    Lagunas-Solar, M.C.

    1985-01-01

    The use of iodine-123 in nuclear medicine procedures is well documented in the scientific literature. Also, several methods for its production based on accelerator techniques have been described. Indirectly made 123 I via the 127 I(p,5n) 123 Xe → 123 I reaction produces 123 I of > 99.9% radionuclidic purity, with only 125 I ( 123 I production were developed at the University of California at Davis, where since 1974 the 76-in. isochronous cyclotron of the Crocker Nuclear Laboratory has been used for routine biweekly production of high-purity no-carrier-added 123 I

  3. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    Science.gov (United States)

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Slow wave cyclotron maser

    International Nuclear Information System (INIS)

    Kho, T.H.; Lin, A.T.

    1988-01-01

    Cyclotron masers such as Gyrotrons and the Autoresonance Masers, are fast wave devices: the electromagnetic wave's phase velocity v rho , is greater than the electron beam velocity, v b . To be able to convert the beam kinetic energy into radiation in these devices the beam must have an initial transverse momentum, usually obtained by propagating the beam through a transverse wiggler magnet, or along a nonuniform guide magnetic field before entry into the interaction region. Either process introduces a significant amount of thermal spread in the beam which degrades the performance of the maser. However, if the wave phase velocity v rho v b , the beam kinetic energy can be converted directly into radiation without the requirement of an initial transverse beam momentum, making a slow wave cyclotron maser a potentially simpler and more compact device. The authors present the linear and nonlinear physics of the slow wave cyclotron maser and examine its potential for practical application

  5. Commercial cyclotrons. Part I: Commercial cyclotrons in the energy range 10 30 MeV for isotope production

    Science.gov (United States)

    Papash, A. I.; Alenitsky, Yu. G.

    2008-07-01

    A survey of commercial cyclotrons for production of medical and industrial isotopes is presented. Compact isochronous cyclotrons which accelerate negative hydrogen ions in the energy range 10 30 MeV have been widely used over the last 25 years for production of medical isotopes and other applications. Different cyclotron models for the energy range 10 12 MeV with moderate beam intensity are used for production of 11C, 13N, 15O, and 18F isotopes widely applied in positron emission tomography. Commercial cyclotrons with high beam intensity are available on the market for production of most medical and industrial isotopes. In this work, the physical and technical parameters of different models are compared. Possibilities of improving performance and increasing intensity of H- beams up to 2 3 mA are discussed.

  6. Cyclotron to Oslo University

    International Nuclear Information System (INIS)

    Sandstad, J.

    1978-01-01

    The new cyclotron was delivered to Oslo University on September 21st 1978, and was mannfactured by A/B Scandtronix of Uppsala, Sweden. The contract price was 6,8 million Norwegian kroner and installation will cost a further 4 million. The main specifications are given. The energy will be 36 MeV for protons and alpha particles, 18 MeV deuterons and 48 MeV for helium 3. The principle of a cyclotron is briefly described. While the primary purpose of the machine is nuclear research it is also planned to produce short-lived radioisotopes, primarily iodine 123. (JIW)

  7. Ramifide resonators for cyclotrons

    International Nuclear Information System (INIS)

    Smirnov, Yu.V.

    2000-01-01

    The resonators with the conductors ramified form for cyclotrons are systematized and separated into the self-contained class - the ramified resonators for cyclotrons (Carr). The ramified resonators are compared with the quarter-wave and half-wave nonramified resonators, accomplished from the transmitting lines fragments. The CRR are classified into two types: ones with the additional structural element, switched in parallel and in series. The CRR may include several additional structural elements. The CRR calculations may be concluded by analytical methods - the method of matrix calculation or the method of telegraph equations and numerical methods - by means of the ISFEL3D, MAFIA and other programs [ru

  8. National Coal Board Medical Service annual report 1981-82

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    Sections report on: medical examinations and consultations; protection from health hazards, such as pneumoconiosis and other prescribed diseases; problems such as vitamin D in miners' blood, Legionnaires' disease, rehabilitation and physiotherapy, high pressure injection injuries, pump packing; National Coal Board (Coal Products) Ltd.; injuries and treatment; and nursing service. A list of staff and their publications and a supplement on occupational toxicology are included.

  9. References from Brazilian medical journals in national publications.

    Science.gov (United States)

    Teixeira, Renan Kleber Costa; Botelho, Nara Macedo; Petroianu, Andy

    2013-01-01

    To assess whether there is a preference for international journal citation to the detriment of national ones in ten Brazilian medical journals, in two different periods. All references in the articles published in Arquivos Brasileiros de Oftalmologia, Revista Brasileira de Cirurgia Cardiovascular, Revista da Associação Médica Brasileira, São Paulo Medical Journal, Arquivos Brasileiros de Endocrinologia e Metabologia, Clinics, Jornal Brasileiro de Pneumologia, Revista da Sociedade Brasileira de Medicina Tropical, Revista Brasileira de Psiquiatria e Acta Ortopédica Brasileira in the years 2011 and 2007 were analyzed, assessing the number of articles published in national and international journals. A total of 36,125 references from 1,462 articles published in the 10 aforementioned journals were analyzed. Of the total number, 4.242 (11.74%) were from Brazilian journals. There was no significant difference between the two analyzed periods. A total of 453 (30,98%) of the articles studied non-cited brazilian papers,and 81 (5.54%) articles had more Brazilian than international references. Of total references analyzed, 11.74% were related to articles published in Brazilian journals. This number, when compared to the percentage of Brazilian articles published in the medical area, demonstrates a good number of citations of national articles. Copyright © 2012 Elsevier Editora Ltda. All rights reserved.

  10. Production of radiopharmaceuticals by cyclotrons

    International Nuclear Information System (INIS)

    Schmitz, F.; Van Naemen, J.; Monclus, M.; Van Gansbeke, B.; Kadiata, M.; Ekelmans, D.; Moray, M.; Penninckx, R.; Goldman, S.

    2004-01-01

    Companies specialized in the development and installation of accelerator-based systems dedicated to the medical applications brought on the market cyclotrons well fitted to the requests of the industrial community or universities and so covering every segment of the market. These machines are fully automatic, and need reduced maintenance; they are highly specialized for defined tasks. They can produce high beam intensity and realize dual beam irradiation. Also the prices are reducing considerably. The targets and the automatic system follow the same trend. Unfortunately, the flexibility of these devices for new area of research and development has been dramatically reduced. The growing number of PET cameras has increased the popularity of PET tracers used for nuclear imaging. Consequently, there is a growing demand for these radiopharmaceuticals compounds labeled with short-lived radioisotopes for clinical applications. From a research and development tool in the eighties, PET has now grown up to a clinical tool. Moreover, depending of the social welfare, reimbursement of some PET examinations is granted, which accelerates the trend for an extended use of PET tracers. Regulatory affairs try to establish and standardize the control on these radiopharmaceutical compounds produced in a growing number of local radio pharmacies owning a baby cyclotron. On the other hand, the attention of equipment suppliers was brought in the setting up of a total quality control follow up. These efforts were successively achieved by getting for instance the ISO 9001 certificate

  11. Can dimensions of national culture predict cross-national differences in medical communication?

    OpenAIRE

    Meeuwesen, L.; Brink, A. van den; Hofstede, G.

    2009-01-01

    OBJECTIVE: This study investigated at a country level how cross-national differences in medical communication can be understood from the first four of Hofstede's cultural dimensions, i.e. power distance, uncertainty avoidance, individualism/collectivism and masculinity/femininity, together with national wealth. METHODS: A total of 307 general practitioners (GPs) and 5820 patients from Belgium, Estonia, Germany, Great Britain, the Netherlands, Poland, Romania, Spain, Sweden and Switzerland par...

  12. Electron-Cyclotron Waves

    NARCIS (Netherlands)

    Westerhof, E.

    1994-01-01

    The essential elements of the theory of electron cyclotron waves are reviewed, The two main electro-magnetic modes of propagation are identified and their dispersion and absorption properties are discussed. The importance of the use of the relativistic resonance condition is stressed.

  13. Biomedical cyclotron facility

    International Nuclear Information System (INIS)

    MacDonald, N.S.; Birdsall, R.; Takahaski, J.; McConnel, L.; Wood, R.; Wakakuwa, S.

    1976-01-01

    During the fifth year of operation the mechanical performance of the cyclotron and accessory equipment was excellent. Major items put into operation were a small computer system interfaced with Ge-Li gamma spectrometer and a pneumatic-tube system for fast delivery of short-lived radionuclides. A table is presented listing the radionuclides produced

  14. Design features and operating characteristics of the MC-50 cyclotron

    International Nuclear Information System (INIS)

    Bak, Hae Ill; Bak, Joo Shik

    1989-01-01

    The MC-50 cyclotron at Korean Cancer Center Hospital is now operational for neutron therapy and medical radioisotope production. Design features, mechanical structures and operating characteristics of the MC-50 are described in this paper. Optimum operating condition for this cyclotron has been determined by the repetitive running, and the performances of the internal beam have been investigated through the measurements of intensity and spatial distribution of the internal beam as a function of the radius of the cyclotron. Routinely, the 40 μA of 50 MeV protons have been obtained at first Faraday cup with a extraction efficiency of 61%. (Author)

  15. Thermal Stabilization of Cryogenic System in Superconducting Cyclotron

    International Nuclear Information System (INIS)

    Shin, Seung Jae; Kim, Kyung Min; Cho, Hyung Hee; Hong, Bong Hwan; Kang, Joon Sun; Ahn, Dong Hyun

    2011-01-01

    Radiology has some useful applications for medical purpose. For cancer therapy, the superconducting cyclotron should generate heavy ion beams. It radiates heavy ion beams to cancer patients. In order to make cyclotron system stable, the cryogenic system which makes superconducting state should work constantly. However, radiation heat transfer of cryogenic system should be considered because liquid helium's boiling point is extremely low and there is huge temperature difference between the cryogenic system and ambient temperature. Accordingly, thermal analysis should be carried out. In this paper, the numerical analysis of the cryogenic system in practical superconducting cyclotron show temperature distribution and suggest the number of coolers using ANSYS Workbench program

  16. Specialty preferences and motivating factors: A national survey on medical students from five uae medical schools.

    Science.gov (United States)

    Abdulrahman, Mahera; Makki, Maryam; Shaaban, Sami; Al Shamsi, Maryam; Venkatramana, Manda; Sulaiman, Nabil; Sami, Manal M; Abdelmannan, Dima K; Salih, AbdulJabbar M A; AlShaer, Laila

    2016-01-01

    Workforce planning is critical for being able to deliver appropriate health service and thus is relevant to medical education. It is, therefore, important to understand medical students' future specialty choices and the factors that influence them. This study was conducted to identify, explore, and analyze the factors influencing specialty preferences among medical students of the United Arab Emirates (UAE). A multiyear, multicenter survey of medical student career choice was conducted with all five UAE medical schools. The questionnaire consisted of five sections. Chi-squared tests, regression analysis, and stepwise logistic regression were performed. The overall response rate was 46% (956/2079). Factors that students reported to be extremely important when considering their future career preferences were intellectual satisfaction (87%), work-life balance (71%), having the required talent (70%), and having a stable and secure future (69%). The majority of students (60%) preferred internal medicine, surgery, emergency medicine, or family Medicine. The most common reason given for choosing a particular specialty was personal interest (21%), followed by flexibility of working hours (17%). The data show that a variety of factors inspires medical students in the UAE in their choice of a future medical specialty. These factors can be used by health policymakers, university mentors, and directors of residency training programs to motivate students to choose specialties that are scarce in the UAE and therefore better serve the health-care system and the national community.

  17. Can dimensions of national culture predict cross-national differences in medical communication?

    NARCIS (Netherlands)

    Meeuwesen, L.; Brink, A. van den; Hofstede, G.

    2009-01-01

    OBJECTIVE: This study investigated at a country level how cross-national differences in medical communication can be understood from the first four of Hofstede's cultural dimensions, i.e. power distance, uncertainty avoidance, individualism/collectivism and masculinity/femininity, together with

  18. Medical Tourism and the Libyan National Health Services

    Directory of Open Access Journals (Sweden)

    El Taguri A

    2007-01-01

    recognized location of choice for quality healthcare and an integrated centre of excellence for clinical and wellness services, medical education and research [2]. An international medical travel conference (IMTC was held in December 2006 and some web sites such as ArabMedicare.com were established to accompany the needs of this growing market.In spite of the aforementioned rewards, medical tourism is not without risks [3]. Medical tourism can do harm to national health services of the host as well as the country of origin. Besides cultural and language issues, there are risks inherent in traveling as accidents, exposure to different infectious diseases, risks from traveling soon after surgery, impossibility of treating chronic disease after a single consultation, the non familiarity of how a certain specialty applies to other communities, the on-off consultations, the limited possibility for follow up, the absence of record of the consultation [3], and most importantly fraud and abuse.The total amount of money spent by Libyans on both forms of medical tourism is difficult to estimate. It ranges between $100-200 millions per year for treatment abroad, but the accurate figures are not available. The form of medical tourism where doctors rather than patients travel, gained a momentum with the increased role of private practice in health service delivery. There is a real threat from the growing market of medical tourism in the region on the public health oriented national health system in Libya. The two neighboring countries that are mostly visited by Libyans have a lower performance of National Health Service in comparison to Libyan National Health services with an objective assessment as revealed by infant mortality rate, life expectancy at birth, maternal mortality ratio and proportion of low birth weight [7]. Giving the non-popularity of tourism among the Libyan population, traveling in itself is an important event in one’s life. We should not deny that in many cases

  19. Automated cyclotron tuning using beam phase measurements

    International Nuclear Information System (INIS)

    Timmer, J.H.; Roecken, H.; Stephani, T.; Baumgarten, C.; Geisler, A.

    2006-01-01

    The ACCEL K250 superconducting cyclotron is specifically designed for the use in proton therapy systems. The compact medical 250 MeV proton accelerator fulfils all present and future beam requirements for fast scanning treatment systems and is delivered as a turn key system; no operator is routinely required. During operation of the cyclotron heat dissipation of the RF system induces a small drift in iron temperature. This temperature drift slightly detunes the magnetic field and small corrections must be made. A non-destructive beam phase detector has been developed to measure and quantify the effect of a magnetic field drift. Signal calculations were made and the design of the capacitive pickup probe was optimised to cover the desired beam current range. Measurements showed a very good agreement with the calculated signals and beam phase can be measured with currents down to 3 nA. The measured phase values are used as input for a feedback loop controlling the current in the superconducting coil. The magnetic field of the cyclotron is tuned automatically and online to maintain a fixed beam phase. Extraction efficiency is thereby optimised continuously and activation of the cyclotron is minimised. The energy and position stability of the extracted beam are well within specification

  20. Can dimensions of national culture predict cross-national differences in medical communication?

    Science.gov (United States)

    Meeuwesen, Ludwien; van den Brink-Muinen, Atie; Hofstede, Geert

    2009-04-01

    This study investigated at a country level how cross-national differences in medical communication can be understood from the first four of Hofstede's cultural dimensions, i.e. power distance, uncertainty avoidance, individualism/collectivism and masculinity/femininity, together with national wealth. A total of 307 general practitioners (GPs) and 5820 patients from Belgium, Estonia, Germany, Great Britain, the Netherlands, Poland, Romania, Spain, Sweden and Switzerland participated in the study. Medical communication was videotaped and assessed using Roter's interaction analysis system (RIAS). Additional context information of physicians (gender, job satisfaction, risk-taking and belief of psychological influence on diseases) and patients (gender, health condition, diagnosis and medical encounter expectations) was gathered by using questionnaires. Countries differ considerably form each other in terms of culture dimensions. The larger a nation's power distance, the less room there is for unexpected information exchange and the shorter the consultations are. Roles are clearly described and fixed. The higher the level of uncertainty avoidance, the less attention is given to rapport building, e.g. less eye contact. In 'masculine' countries there is less instrumental communication in the medical interaction, which was contrary to expectations. In wealthy countries, more attention is given to psychosocial communication. The four culture dimensions, together with countries' wealth, contribute importantly to the understanding of differences in European countries' styles of medical communication. Their predictive power reaches much further than explanations along the north/south or east/west division of Europe. The understanding of these cross-national differences is a precondition for the prevention of intercultural miscommunication. Improved understanding may occur at microlevel in the medical encounter, as well as on macrolevel in pursuing more effective cooperation and

  1. Research priorities in medical education: A national study

    Directory of Open Access Journals (Sweden)

    Mina Tootoonchi

    2012-01-01

    Full Text Available Background: One preliminary step to strengthen medical education research would be determining the research prior-ities. The aim of this study was to determine the research priorities of medical education in Iran in 2007-2008. Methods: This descriptive study was carried out in two phases. Phase one was performed in 3 stages and used Delphi technique among academic staffs of Isfahan University of Medical Sciences. The three stages included a brainstorming workshop for 140 faculty members and educational experts resulting in a list of research priorities, then, in the second and third stages 99 and 76 questionnaires were distributed among faculty members. In the second phase, the final ques-tionnaires were mailed to educational research center managers of universities type I, II and III, and were distributed among 311 academic members and educational experts to rate the items on a numerical scale ranging from 1 to 10. Results: The most important research priorities included faculty members′ development methods, faculty members′ motives, satisfaction and welfare, criteria and procedures of faculty members′ promotion, teaching methods and learning techniques, job descriptions and professional skills of graduates, quality management in education, second language, clinical education, science production in medicine, faculty evaluation and information technology. Conclusions: This study shows the medial education research priorities in national level and in different types of medical universities in Iran. It is recommended that faculty members and research administrators consider the needs and requirements of education and plan the researches in education according to these priorities.

  2. Research priorities in medical education: A national study.

    Science.gov (United States)

    Tootoonchi, Mina; Yamani, Nikoo; Changiz, Tahereh; Yousefy, Alireza

    2012-01-01

    One preliminary step to strengthen medical education research would be determining the research priorities. The aim of this study was to determine the research priorities of medical education in Iran in 2007-2008. This descriptive study was carried out in two phases. Phase one was performed in 3 stages and used Delphi technique among academic staffs of Isfahan University of Medical Sciences. The three stages included a brainstorming workshop for 140 faculty members and educational experts resulting in a list of research priorities, then, in the second and third stages 99 and 76 questionnaires were distributed among faculty members. In the second phase, the final questionnaires were mailed to educational research center managers of universities type I, II and III, and were distributed among 311 academic members and educational experts to rate the items on a numerical scale ranging from 1 to 10. The most important research priorities included faculty members' development methods, faculty members' motives, satisfaction and welfare, criteria and procedures of faculty members' promotion, teaching methods and learning techniques, job descriptions and professional skills of graduates, quality management in education, second language, clinical education, science production in medicine, faculty evaluation and information technology. This study shows the medial education research priorities in national level and in different types of medical universities in Iran. It is recommended that faculty members and research administrators consider the needs and requirements of education and plan the researches in education according to these priorities.

  3. National Undergraduate Medical Core Curriculum in Turkey: Evaluation of Residents

    Directory of Open Access Journals (Sweden)

    Işıl İrem Budakoğlu

    2014-03-01

    Full Text Available Background: There is very little information available on self-perceived competence levels of junior medical doctors with regard to definitions by the National Core Curriculum (NCC for Undergraduate Medical Education. Aims: This study aims to determine the perceived level of competence of residents during undergraduate medical education within the context of the NCC. Study Design: Descriptive study. Methods: The survey was conducted between February 2010 and December 2011; the study population comprised 450 residents. Of this group, 318 (71% participated in the study. Self-assessment questionnaires on competencies were distributed and residents were asked to assess their own competence in different domains by scoring them on a scale of 1 to 10. Results: Nearly half of the residents reported insufficient experience of putting clinical skills into practice when they graduated. In the theoretical part of NCC, the lowest competency score was reported for health-care administration, while the determination of level of chlorine in water, delivering babies, and conducting forensic examinations had the lowest perceived levels of competency in the clinical skills domain. Conclusion: Residents reported low levels of perceived competency in skills they rarely performed outside the university hospital. They were much more confident in skills they performed during their medical education.

  4. NIH's National Institute of General Medical Sciences celebrates 45 years of Discovery for Health

    Science.gov (United States)

    ... Alison Davis NIH's National Institute of General Medical Sciences celebrates 45 years of Discovery for Health The National Institute of General Medical Sciences (NIGMS) is the NIH institute that primarily supports ...

  5. National Synchrotron Light Source medical personnel protection interlock

    Energy Technology Data Exchange (ETDEWEB)

    Buda, S.; Gmuer, N.F.; Larson, R.; Thomlinson, W.

    1998-11-01

    This report is founded on reports written in April 1987 by Robert Hettel for angiography operations at the Stanford Synchrotron Research Laboratory (SSRL) and a subsequent report covering angiography operations at the National Synchrotron Light Source (NSLS); BNL Informal Report 47681, June 1992. The latter report has now been rewritten in order to accurately reflect the design and installation of a new medical safety system at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). Known originally as the Angiography Personnel Protection Interlock (APPI), this system has been modified to incorporate other medical imaging research programs on the same beamline and thus the name has been changed to the more generic Medical Personnel Protection Interlock (MPPI). This report will deal almost exclusively with the human imaging (angiography, bronchography, mammography) aspects of the safety system, but will briefly explain the modular aspects of the system allowing other medical experiments to be incorporated. This MPPI report is organized such that the level of detail changes from a general overview to detailed engineering drawings of the hardware system. The general overview is presented in Section 1.0, MPPI Operational Mode and Procedures. The various MPPI components are described in detail in Section 2.0. Section 3.0 presents some simplified logic diagrams and accompanying text. This section was written to allow readers to become familiar with the logic system without having to work through the entire set of detailed engineering drawings listed in the Appendix. Detailed logic specifications are given in Section 4.0. The Appendix also contains copies of the current MPPI interlock test procedures for Setup and Patient Modes.

  6. 77 FR 13312 - National Committee on Foreign Medical Education and Accreditation

    Science.gov (United States)

    2012-03-06

    ... DEPARTMENT OF EDUCATION National Committee on Foreign Medical Education and Accreditation AGENCY: National Committee on Foreign Medical Education and Accreditation, Office of Postsecondary Education, U.S... National Committee on Foreign Medical Education and Accreditation (NCFMEA). Parts of this meeting will be...

  7. 78 FR 9899 - National Committee on Foreign Medical Education and Accreditation

    Science.gov (United States)

    2013-02-12

    ... DEPARTMENT OF EDUCATION National Committee on Foreign Medical Education and Accreditation AGENCY: Office of Postsecondary Education, U.S. Department of Education, National Committee on Foreign Medical... National Committee on Foreign Medical Education and Accreditation (NCFMEA). Parts of this meeting will be...

  8. 77 FR 49788 - National Committee on Foreign Medical Education and Accreditation

    Science.gov (United States)

    2012-08-17

    ... DEPARTMENT OF EDUCATION National Committee on Foreign Medical Education and Accreditation AGENCY: Office of Postsecondary Education, U.S. Department of Education, National Committee on Foreign Medical... National Committee on Foreign Medical Education and Accreditation (NCFMEA). Parts of this meeting will be...

  9. Goodbye Synchro-Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1990-12-15

    On 17 December, after having seen many other physics machines come and go during its 33-year career, CERN's 600 MeV SynchroCyclotron (SC) is being shut down. Judged simply by its length (to say nothing of its quality), the research career of this machine testifies to the wisdom and imagination of the CERN pioneers who proposed it in the early 1950s.

  10. Goodbye Synchro-Cyclotron

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    On 17 December, after having seen many other physics machines come and go during its 33-year career, CERN's 600 MeV SynchroCyclotron (SC) is being shut down. Judged simply by its length (to say nothing of its quality), the research career of this machine testifies to the wisdom and imagination of the CERN pioneers who proposed it in the early 1950s

  11. Cyclotrons in developing countries

    International Nuclear Information System (INIS)

    Vera Ruiz, Hernan

    2004-01-01

    Cyclotron accelerators are prolific sources of charged particle for the production of radionuclides and have become an essential tool in the practice of modern nuclear medicine by providing reliable radiotracers for SPECT and PET studies. In a recent survey conducted by the IAEA in 2001, the growth in the number of cyclotron facilities installed in laboratories and hospitals in developed as well as developing countries was recorded. This trend, which started in the late 70's, continues in the present time also and all indications are that it will continue in the next five to ten years. The reasons for this growth are several: technology involved has become more user or 'hospital friendly', third party reimbursement for several clinical studies based on F-18 PET radiopharmaceuticals at least in some of the advanced countries started in 1998 and above all, the clear irrefutable and demonstrable conclusion of the positive cost/benefit outcomes of PET studies in the field of oncology to a lesser degree, thus far, for cardiology and neurology. It is however recognizable that the overall financial cost of the technology, which comprises the premises to house the facility, the cyclotron accelerator, the corresponding radiochemistry and quality control equipment and the PET cameras can be nevertheless an expensive proposition that requires careful advance planning. This fact is even more relevant when the facility is planned for installation in a developing country, which, frequently, in addition to having a lack of sufficient financial resources, do have shortage of qualified human resources to efficiently run the facility. In spite of the above, it is fact that more and more public as well as private organizations in the developing countries are setting up cyclotron/PET programmes or are seriously considering the installation of such a facility

  12. Startup work on Inshas cyclotron

    International Nuclear Information System (INIS)

    Vorogushin, M.F.; Strokach, A.P.; Shikhov, V.Ya.; Galchuk, A.V.; Soliman, A.N.; El-Abyad, M.; Comsan, M.N.H.; Saleh, Z.A.; Azzam, A.N.

    2001-01-01

    Startup works on the MGC-20 variable energy cyclotron in the Inshas Nuclear Research Center (Egypt) are described. The cyclotron is intended for acceleration of hydrogen and helium ions in a wide energy range (for protons - from 5 to 20 MeV). Main units of the cyclotron and results of computer experimental acceleration of protons to 18 MeV are described. The prospects of furthers investigations are presented [ru

  13. H-superconducting cyclotron for PET isotope production

    International Nuclear Information System (INIS)

    Smirnov, V.L.; Vorozhtsov, S.B.; Vincent, J.

    2014-01-01

    The scientific design of a 14-MeV H - compact superconducting cyclotron for producing of the 18 F and 13 N isotopes has been developed. Main requirements to the facility as a medical accelerator are met in the design. In particular, the main requirement for the cyclotron was the smallest possible size due to the superconducting magnet. The calculations show that the proposed cyclotron allows extracted beam intensity over 500 μA. To increase system reliability and production rates, an external H - ion source is applied. The choice of the cyclotron concept, design of the structure elements, calculation of the electromagnetic fields and beam dynamics from the ion source to the extraction system were performed.

  14. Development of baby cyclotron for PET in Korea

    International Nuclear Information System (INIS)

    Chai, J.S.; Kim, Y.S.; Hu, J.Y.; Shin, Y.C.; Yoon, M.H.

    2001-01-01

    Development of a 13 MeV cyclotron for Positron Emission Tomography (PET) has been in progress since April 1999 at the Korea Cancer Center Hospital (KCCH). The study has been carried out in a joint collaboration between KCCH and the Pohang University of Science and Technology (POSTECH). Increasing desire for an uninterrupted, reliable and timely supply of the isotopes to customers has prompted obtaining a dedicated 5-13 MeV cyclotron for PET applications and pursuing the purchase of another 30MeV medical cyclotron in the very near future. A decision has been made to design the PET cyclotron in Korea. This will not only ease the problems associated with maintenance during operation but also keep the door open for continuous upgrading of the machine in the future

  15. Magnet design and test of positron emission tomography cyclotron

    International Nuclear Information System (INIS)

    Wei Tao; Yang Guojun; He Xiaozhong; Pang Jian; Zhao Liangchao; Zhang Kaizhi

    2012-01-01

    An 11 MeV H - compact cyclotron used for medical radioactive isotope production is under construction in Institute of Fluid Physics, CAEP. The cyclotron magnet adopts the design of small valley gaps and coulee structure which can provide high average magnetic field and strong focus ability. To achieve 5 × 10 -4 measuring accuracy, a magnetic field mapping system has been developed. After iterative correction using field measurement data, the total phase excursion of the cyclotron is within ± 9° and the first harmonic is less than 10 -3 T, which are all acceptable. Furthermore, the beam testing declares the successful construction of the cyclotron magnet. Besides, some magnetic field influence factors were discussed, including the magnetic field distortion and measurement error. (authors)

  16. Developing drug formularies for the "National Medical Holding" JSC.

    Science.gov (United States)

    Akhmadyar, N S; Khairulin, B E; Amangeldy-Kyzy, S; Ospanov, M A

    2015-01-01

    One of the main problems of drug provision of multidisciplinary hospitals is the necessity to improve the efficiency of budget spending. Despite the efforts undertaken in Kazakhstan for improving the mechanism of drug distribution (creation of the Kazakhstan National Formulary, Unified National Health System, the handbook of medicines (drugs) costs in the electronic register of inpatients (ERI), having a single distributor), the number of unresolved issues still remain."National Medical Holding" JSC (NMH) was established in 2008 and unites 6 innovational healthcare facilities with up to 1431 beds (700 children and 731 adults), located in the medical cluster - which are "National Research Center for Maternal and Child Health" JSC (NRCMC), "Republic Children's Rehabilitation Center" JSC (RCRC), "Republican Diagnostic Center" JSC (RDC), "National Centre for Neurosurgery" JSC (NCN), "National Research Center for Oncology and Transplantation" JSC (NRCOT) and "National Research Cardiac Surgery Center" JSC (NRCSC). The main purpose of NMH is to create an internationally competitive "Hospital of the Future", which will provide the citizens of Kazakhstan and others with a wide range of medical services based on advanced medical technology, modern hospital management, international quality and safety standards. These services include emergency care, outpatient diagnostic services, obstetrics and gynecology, neonatal care, internal medicine, neurosurgery, cardiac surgery, transplantation, cancer care for children and adults, as well as rehabilitation treatment. To create a program of development of a drug formulary of NMH and its subsidiaries. In order to create drug formularies of NMH, analytical, software and statistical methods were used.AII subsidiary organizations of NMH (5 out of 6) except for the NRCOT have been accredited by Joint Commission International (JCI) standards, which ensure the safety of patients and clinical staff, by improving the technological

  17. National Assessment of Quality Programs in Emergency Medical Services.

    Science.gov (United States)

    Redlener, Michael; Olivieri, Patrick; Loo, George T; Munjal, Kevin; Hilton, Michael T; Potkin, Katya Trudeau; Levy, Michael; Rabrich, Jeffrey; Gunderson, Michael R; Braithwaite, Sabina A

    2018-01-01

    This study aims to understand the adoption of clinical quality measurement throughout the United States on an EMS agency level, the features of agencies that do participate in quality measurement, and the level of physician involvement. It also aims to barriers to implementing quality improvement initiatives in EMS. A 46-question survey was developed to gather agency level data on current quality improvement practices and measurement. The survey was distributed nationally via State EMS Offices to EMS agencies nation-wide using Surveymonkey©. A convenience sample of respondents was enrolled between August and November, 2015. Univariate, bivariate and multiple logistic regression analyses were conducted to describe demographics and relationships between outcomes of interest and their covariates using SAS 9.3©. A total of 1,733 surveys were initiated and 1,060 surveys had complete or near-complete responses. This includes agencies from 45 states representing over 6.23 million 9-1-1 responses annually. Totals of 70.5% (747) agencies reported dedicated QI personnel, 62.5% (663) follow clinical metrics and 33.3% (353) participate in outside quality or research program. Medical director hours varied, notably, 61.5% (649) of EMS agencies had quality measures compared to fire-based agencies. Agencies in rural only environments were less likely to follow clinical quality metrics. (OR 0.47 CI 0.31 -0.72 p quality improvement resources, medical direction and specific clinical quality measures. More research is needed to understand the impact of this variation on patient care outcomes.

  18. Ion cyclotron resonance heating

    International Nuclear Information System (INIS)

    Tajima, T.

    1982-01-01

    Ion cyclotron resonance heating of plasmas in tokamak and EBT configurations has been studied using 1-2/2 and 2-1/2 dimensional fully self-consistent electromagnetic particle codes. We have tested two major antenna configurations; we have also compared heating efficiencies for one and two ion species plasmas. We model a tokamak plasma with a uniform poloidal field and 1/R toroidal field on a particular q surface. Ion cyclotron waves are excited on the low field side by antennas parallel either to the poloidal direction or to the toroidal direction with different phase velocities. In 2D, minority ion heating (vsub(perpendicular)) and electron heating (vsub(parallel),vsub(perpendicular)) are observed. The exponential electron heating seems due to the decay instability. The minority heating is consistent with mode conversion of fast Alfven waves and heating by electrostatic ion cyclotron modes. Minority heating is stronger with a poloidal antenna. The strong electron heating is accompanied by toroidal current generation. In 1D, no thermal instability was observed and only strong minority heating resulted. For an EBT plasma we model it by a multiple mirror. We have tested heating efficiency with various minority concentrations, temperatures, mirror ratios, and phase velocities. In this geometry we have beach or inverse beach heating associated with the mode conversion layer perpendicular to the toroidal field. No appreciable electron heating is observed. Heating of ions is linear in time. For both tokamak and EBT slight majority heating above the collisional rate is observed due to the second harmonic heating. (author)

  19. Synchrotron radiation applications in medical research at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Thomlinson, W.

    1997-08-01

    In the relatively short time that synchrotrons have been available to the scientific community, their characteristic beams of UV and X-ray radiation have been applied to virtually all areas of medical science which use ionizing radiation. The ability to tune intense monochromatic beams over wide energy ranges clearly differentiates these sources from standard clinical and research tools. The tunable spectrum, high intrinsic collimation of the beams, polarization and intensity of the beams make possible in-vitro and in-vivo research and therapeutic programs not otherwise possible. From the beginning of research operation at the National Synchrotron Light Source (NSLS), many programs have been carrying out basic biomedical research. At first, the research was limited to in-vitro programs such as the x-ray microscope, circular dichroism, XAFS, protein crystallography, micro-tomography and fluorescence analysis. Later, as the coronary angiography program made plans to move its experimental phase from SSRL to the NSLS, it became clear that other in-vivo projects could also be carried out at the synchrotron. The development of SMERF (Synchrotron Medical Research Facility) on beamline X17 became the home not only for angiography but also for the MECT (Multiple Energy Computed Tomography) project for cerebral and vascular imaging. The high energy spectrum on X17 is necessary for the MRT (Microplanar Radiation Therapy) experiments. Experience with these programs and the existence of the Medical Programs Group at the NSLS led to the development of a program in synchrotron based mammography. A recent adaptation of the angiography hardware has made it possible to image human lungs (bronchography). Fig. 1 schematically depicts the broad range of active programs at the NSLS

  20. Feasibility study of medical isotope production at Sandia National Laboratories

    International Nuclear Information System (INIS)

    Massey, C.D.; Miller, D.L.; Carson, S.D.

    1995-12-01

    In late 1994, Sandia National Laboratories in Albuquerque, New Mexico, (SNL/NM), was instructed by the Department of Energy (DOE) Isotope Production and Distribution Program (IPDP) to examine the feasibility of producing medically useful radioisotopes using the Annular Core Research Reactor (ACRR) and the Hot Cell Facility (HCF). Los Alamos National Laboratory (LANL) would be expected to supply the targets to be irradiated in the ACRR. The intent of DOE would be to provide a capability to satisfy the North American health care system demand for 99 Mo, the parent of 99m Tc, in the event of an interruption in the current Canadian supply. 99m Tc is used in 70 to 80% of all nuclear medicine procedures in the US. The goal of the SNL/NM study effort is to determine the physical plant capability, infrastructure, and staffing necessary to meet the North American need for 99 Mo and to identify and examine all issues with potential for environmental impact

  1. Solid targetry for compact cyclotrons

    International Nuclear Information System (INIS)

    Comor, J.

    2004-01-01

    In this presentation authors present experimental results of solid targetry for compact cyclotrons. It is concluded: Solid targetry is not restricted to large accelerator centers anymore; Small and medium scale radioisotope production is feasible with compact cyclotrons; The availability of versatile solid target systems is expected to boost the radiochemistry of 'exotic' positron emitters

  2. Cyclotrons and positron emitting radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs. (ACR)

  3. Status report on cyclotron operation

    International Nuclear Information System (INIS)

    Kovacs, P.; Szuecs, I.; Ander, I.; Lakatos, T.; Fenyvesi, A.; Ditroi, F.; Takacs, S.; Tarkanyi, F.

    2004-01-01

    The operation of the cyclotron in 2003 was again concentrated to 9 months; January, July and August were reserved for maintenance, renewal works and holidays. The overall working time of the accelerator was 4051 hours. The cyclotron was available for users for 3682 hours. In order to improve the circumstances of the irradiations renewal and improvements were done. (N.T.)

  4. Cyclotrons and positron emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs

  5. Implicit and Explicit Weight Bias in a National Sample of 4732 Medical Students: The Medical Student CHANGES Study

    OpenAIRE

    Phelan, Sean M.; Dovidio, John F.; Puhl, Rebecca M.; Burgess, Diana J.; Nelson, David B.; Yeazel, Mark W.; Hardeman, Rachel; Perry, Sylvia; van Ryn, Michelle

    2014-01-01

    Objective To examine the magnitude of explicit and implicit weight biases compared to biases against other groups; and identify student factors predicting bias in a large national sample of medical students. Design and Methods A web-based survey was completed by 4732 1st year medical students from 49 medical schools as part of a longitudinal study of medical education. The survey included a validated measure of implicit weight bias, the implicit association test, and 2 measures of explicit bi...

  6. National Programme for Radiological Protection in Medical Exposures

    International Nuclear Information System (INIS)

    2013-07-01

    A national programme on radiation protection of patients can only be effective and sustainable if there is a joint effort between the regulatory body and the health authorities, and a cooperation with educational institutions, professional bodies and representatives of the industry. The regulatory body needs to promote a strategy of cooperation, and to identify obstacles that may prevent compliance with regulatory requirements and to address them. Not of least is the need for a continuous self-evaluation on the efficacy of the programme. Radiation safety of the patients is a responsibility of the users of the radiation sources involved in diagnostic and treatment. In particular, they are responsible for compliance with regulatory requirements. But safety depends also on aspects that are beyond the capabilities of those authorized to conduct practices. These aspects include educational programmes and institutions to implement them, calibration facilities, national protocols, professional bodies for the establishment of reference levels and contributions from the industry. Neither the users nor the regulatory body alone can achieve that these elements are in place. It needs a network of institutions and cooperation arrangements that involve educational and health authorities, laboratory facilities, professional bodies and the industry. A national programme has to include a strategy of cooperation, identification of obstacles that may prevent compliance with regulatory requirements and address them. Not of least is the need for a continuous self-evaluation on the efficacy of the programme. A group of regulatory agencies belonging to the Ibero American Forum of Nuclear and Radiation Regulatory Agency have exchanged experiences, lessons learned and good practices over three years. This exchange included extensive collaboration with the health authorities. The result of this work is this document containing a self-evaluation approach for the regulatory programme on

  7. Atmospheric tracer study of the emissions from the University of Michigan Cyclotron/PET Facility

    International Nuclear Information System (INIS)

    Scofield, P.A.

    1986-01-01

    The University of Michigan (U of M) Cyclotron/Positron Emission Tomography (PET) facility consists of a cyclotron (Model CS-30, The Cyclotron Corporation), radiochemistry laboratory, and Pet scanner. Accelerator-produced radioactive materials, such as, carbon-11 and oxygen-15 are typically emitted from the Cyclotron/PET facility through short stacks located on the roof. This project studied the dispersion of emissions from the facility within the medical complex. To achieve this purpose, the research project had three phases: a physical modeling study; a preliminary field smoke release study; and, a field study using a tracer gas to simulate emission dispersion from the U of M Cyclotron/PET facility vault stack. The objective was to determine normalized concentrations, under selected wind directions and speeds, for use in establishing radionuclide concentrations at the air intakes of the Cyclotron/PET facility and surrounding buildings and at selected ground-level locations

  8. Understanding Medical Words: A Tutorial from the National Library of Medicine

    Science.gov (United States)

    ... page: https://medlineplus.gov/medicalwords.html Understanding Medical Words: A Tutorial from the National Library of Medicine ... enable JavaScript. This tutorial teaches you about medical words. You'll learn about how to put together ...

  9. Applied research with cyclotrons

    International Nuclear Information System (INIS)

    Apel, P.; Dmitriev, S.; Gulbekian, G.; Gikal, B.; Ivanov, O.; Reutov, V.; Skuratov, V.

    2005-01-01

    During the past three decades the Flerov laboratory carried out research and development of a number of applications that have found or may find use in modern technologies. One of the applications is the so-called ion track technology enabling us to create micro- and nano-structured materials. Accelerated heavy ion beams are the unique tools for structuring insulating solids in a controllable manner. At FLNR JINR the U-400 cyclotron and the IC-100 cyclotron are employed for irradiation of materials to be modified by the track-etch technique. For practical applications, U-400 delivers the 86 Kr ion beams with total energies of 250, 350, 430 and 750 MeV, and the 136 Xe ion beams with the energy of 430 MeV. The cyclotron is equipped with a specialized channel for irradiation of polymer foils. IC-100 is a compact accelerator specially designed for the technological uses. High-intensity krypton ion beams with the energy of ∼ 1 MeV/u are available now at IC-100. Production of track-etch membranes is an example of mature technology based on irradiation with accelerated ions. The track-etch membranes offer distinct advantages over other types of membranes due to their precisely determined structure. One-pore, oligo-pore and multi-pore samples can serve as models for studying the transport of liquids, gases, particles, solutes, and electrolytes in narrow channels. Track-etch pores are also used as templates for making nano wires, nano tubes or array of nano rods. The microstructures obtained this way may find use in miniaturized devices such as sensors for biologically important molecules. Bulk and surface modification for the production of new composites and materials with special optical properties can be performed with ion beams. Flexible printed circuits, high-performance heat transfer modules, X-ray filters, and protective signs are examples of products developed in collaboration with research and industrial partners. Some recent achievements and promising ideas that

  10. Design study of the KIRAMS-430 superconducting cyclotron magnet

    International Nuclear Information System (INIS)

    Kim, Hyun Wook; Kang, Joonsun; Hong, Bong Hwan; Jung, In Su

    2016-01-01

    Design study of superconducting cyclotron magnet for the carbon therapy was performed at the Korea Institute of Radiological and Medical Science (KIRAMS). The name of this project is The Korea Heavy Ion Medical Accelerator (KHIMA) project and a fixed frequency cyclotron with four spiral sector magnet was one of the candidate for the accelerator type. Basic parameters of the cyclotron magnet and its characteristics were studied. The isochronous magnetic field which can guide the "1"2C"6"+ ions up to 430 MeV/u was designed and used for the single particle tracking simulation. The isochronous condition of magnetic field was achieved by optimization of sector gap and width along the radius. Operating range of superconducting coil current was calculated and changing of the magnetic field caused by mechanical deformations of yokes was considered. From the result of magnetic field design, structure of the magnet yoke was planned.

  11. Radiation monitoring in a self-shielded cyclotron installation

    International Nuclear Information System (INIS)

    Capaccioli, L.; Gori, C.; Mazzocchi, S.; Spano, G.

    2002-01-01

    As nuclear medicine is approaching a new era with the spectacular growth of PET diagnosis, the number of medical cyclotrons installed within the major hospitals is increasing accordingly. Therefore modern medical cyclotron are highly engineered and highly reliable apparatus, characterised with reduced accelerating energies (as the major goal is the production of fluorine 18) and often self-shielded. However specific dedicated monitors are still necessary in order to assure the proper radioprotection. At the Careggi University Hospital in Florence a Mini trace 10 MeV self-shielded cyclotron produced by General Electric has been installed in 2000. In a contiguous radiochemistry laboratory, the preparation and quality control of 1 8F DG and other radiopharmaceuticals takes place. Aim of this work is the characterisation and the proper calibration of the above mentioned monitors and control devices

  12. Design study of the KIRAMS-430 superconducting cyclotron magnet

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Wook; Kang, Joonsun, E-mail: genuinei@kirams.re.kr; Hong, Bong Hwan; Jung, In Su

    2016-07-01

    Design study of superconducting cyclotron magnet for the carbon therapy was performed at the Korea Institute of Radiological and Medical Science (KIRAMS). The name of this project is The Korea Heavy Ion Medical Accelerator (KHIMA) project and a fixed frequency cyclotron with four spiral sector magnet was one of the candidate for the accelerator type. Basic parameters of the cyclotron magnet and its characteristics were studied. The isochronous magnetic field which can guide the {sup 12}C{sup 6+} ions up to 430 MeV/u was designed and used for the single particle tracking simulation. The isochronous condition of magnetic field was achieved by optimization of sector gap and width along the radius. Operating range of superconducting coil current was calculated and changing of the magnetic field caused by mechanical deformations of yokes was considered. From the result of magnetic field design, structure of the magnet yoke was planned.

  13. Isochronous cyclotron data base description

    International Nuclear Information System (INIS)

    Kiyan, I.N.; Vorozhtsov, S.B.; Tarashkevich, R.

    2004-01-01

    The relational data base of the control parameters of the isochronous cyclotron, Isochronous Cyclotron Data Base (ICDB), is described. The relational data base under consideration, written in Transact SQL for the MS SQL Server 2000 with the use of MS Enterprise Manager and MS Query Analyzer, was installed on the server of the AIC144 isochronous cyclotron in Krakow, which operates under the control of the operating system MS Windows Server 2003 (Standard Edition). The interface of the data base under considerations is written in C++ with the use of Visual C++ .NET and is built in the Cyclotron Operator Help Program (COHP), which is used for modeling the operational modes of the isochronous cyclotron. Communication between the COHP and the relational data base is realised on the base of the Open Data Base Connectivity protocol. The relational data base of the control parameter of the isochronous cyclotron is intended: firstly, for systematization and automatic use of all measured and modelled magnetic field maps in the process of modeling the operational modes; secondly, for systematization and convenient access to the stored operational modes; thirdly, for simplifying the operator's work. The relational data base of the control parameter of the isochronous cyclotron reflects its physical structure and the logic of its operator's work. (author)

  14. Medical Managment of the Acute Radiation Syndrome: Recommendations of the Strategic National Stockpile Radiation Working Group

    National Research Council Canada - National Science Library

    Waselenka, Jamie K; MacVittie, Thomas J; Blakely, William F; Pesik, Nicki; Wiley, Albert L; Dickerson, William E; Tsu, Horace; Confer, Dennis L; Coleman, Norman; Seed, Thomas

    2004-01-01

    .... This consensus document was developed by the Strategic National Stockpile Radiation Working Group to provide a framework for physicians in internal medicine and the medical subspecialties to evaluate...

  15. 78 FR 66947 - National Institute of General Medical Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2013-11-07

    ... Person: Robert Horowits, Ph.D., Senior Investigator, National Institute of General Medical Sciences..., Pharmacology, Physiology, and Biological Chemistry Research; 93.862, Genetics and Developmental Biology...

  16. Verification of the shielding built for a Cyclotron accelerator; Verificacao da blindagem construida para um acelerador do tipo Ciclotron

    Energy Technology Data Exchange (ETDEWEB)

    Videira, Heber S., E-mail: heber@cyclopet.com [CYCLOPET Radiofarmacos LTDA., Curitiba, PR (Brazil); Passaro, Bruno M.; Gonzalez, Julia A.; Guimaraes, Maria Ines C.C.; Buchpigue, Carlos A. [Centro de Medicina Nuclear (CMN) do InRad HCFMUSP, Sao Paulo, SP (Brazil)

    2012-08-15

    According to the National Nuclear Energy Commission (CNEN) resolution 112/2011, administrative controls must be applied during the construction of a cyclotron and documents must be created showing that the facility can operate without radiological risks, referring even to the shielding efficiency. This study aimed to perform the analysis of the construction and efficiency of the bunker built for shielding, in the cyclotron of University of Sao Paulo Medical School Health System. This was possible through the measurements of a radiometric survey in normal working conditions, and testing related to compression resistance and density. The results showed that the compression resistance of the concrete used is higher than the expected value and the average density value obtained is within the tolerated limits. The radiometric survey results showed that the levels of ionizing radiation are well below the established limits. (author)

  17. [Cyclotron based nuclear science

    International Nuclear Information System (INIS)

    1991-08-01

    This report contains descriptions of research programs carried out by Institute staff, as well as progress on new instrumentation during the period, April 1, 1990, to March 31, 1991. The K500 cyclotron and ECR source provided beam for 4140 hours during the period. The beam was actually available for experiments 1927.50 hours and 1110.50 hours was devoted to developing new beams and exploring cyclotron performance. A wide range of beams from protons to Xe with energies from 2.4 MeV/u to 60 MeV/U have been used in experiments. The highest total energy beam accelerated was 35 MeV/u 63 Cu. The ECR source, made a tremendous improvement in accelerator performance and reliability. Substantial amounts of beam time were devoted to investigations of hot nuclei, electron-positron, giant resonances, atomic effects of high velocity ion beams, astrophysics related reactions and proton and alpha bremsstrahlung. Scientific accomplishments included determination of the heat capacity of nuclei through new insight into the level densities and establishing a lower limit for electron positron resonances a factor of ten better than previous measurements. The proton spectrometer, constructed for studies of the Gamow-Teller interaction is complete, and initial physics measurements will be made in the next few months. All of the BaF 2 crystals have been delivered and acceptance tests are underway. A K=315 MDM spectrometer has been obtained from Oxford University and is scheduled for installation in Spring 1992, after removal of the K=150 Enge split pole spectrometer. Institute groups continue participation in MEGA, instrumentation projects for RHIC, and few nucleon studies at LAMPF and KEK. Reports of these activities are included

  18. Medical Diplomacy: A Tool for Enabling National Security Strategy Objectives

    Science.gov (United States)

    2012-04-06

    USGs global health portfolio includes a diverse set of programs and investments in...cultural linguistic competency, expertise in regional medical initiatives, and knowledge of joint coordination in the ability foster medical goodwill...operates medical research units in Egypt and Peru . Additionally, the Navy has operated facilities in Indonesia and maintains research capabilities

  19. The Cyclotron Center of the Slovak Republic

    International Nuclear Information System (INIS)

    Podhorsky, D.; Ruzicka, J.; Macasek, F.; Makaiova, I.; Saro, S.; Kristiak, J.; Fulup, M.

    2001-01-01

    The Cyclotron Center of the Slovak Republic was established at the beginning of August 1999 - within the Slovak-Office of Standards, Metrology and Testing (SOSMT), in Bratislava, Slovak Republic. It will have two cyclotrons - a large heavy and light cyclotron DC-72, which will be constructed by the Joint Institute for Nuclear Research (JINR), Dubna, Russian Federation, and a small commercial light ion cyclotron IBA 18/9. The heavy ion source of the electron resonance type (DECRS-2M) will be used for low and medium energy experiments in physics. The small electron accelerator is planned for different applications, including improving the properties of plastics, increasing the resistance of cables to fire and temperature, the sterilization of medical disposables in the CC SR. The main purpose of the Cyclotron Center of the Slovak Republic (CC SR) is to catch the present approach and trends in the area of improving of inhabitants life and health quality using the progressive technology, which is introduced by bringing into practice of the physical equipment - accelerators, producing beams of high energy particles. Experts of nuclear physics and of the related branches have no experimental basis in Slovakia, as after dissolution of the former the Czech and Slovak Federal Republic all bigger nuclear equipment were left in the Czech Republic. The Slovak Republic is one of the European countries where cancer and cardiovascular diseases have a rapidly increasing tendency (the rate of new oncological cases is approximately 20,000/year at the population of 5 million inhabitants) - early diagnostics of population is necessary to be updated urgently. The Slovak Republic use a great part of electricity (about 60 %) from its own nuclear power stations and thus it is in need of education of rising generations of experts from different nuclear fields. The Government of the Slovak republic on June 18, 1996 approved the strategic aim of building up the Cyclotron Laboratory at the

  20. Isotope separation by ionic cyclotron resonance

    International Nuclear Information System (INIS)

    Compant La Fontaine, A.; Gil, C.; Louvet, P.

    1986-10-01

    The principle of the process of isotopic separation by ionic cyclotron resonance is explained succinctly. The theoretical calculation of the isotopic effect is given as functions of the electric and magnetic fields in the frame of single particle approximation and of plasma collective theory. Then, the main parts of the demonstration device which is in operation at the CEA, are described here: the supraconducting magnetic field, the used diagnostics, the principle of the source and the collecting apparatus. Some experimental results are given for chromium. The application of the process to ponderal separation of metal isotopes, as chromium, nickel and molybdenum is discussed in view of production of medical, structural and irradiation isotopes

  1. Ion Cyclotron Resonance Facility (ICR)

    Data.gov (United States)

    Federal Laboratory Consortium — his facility is charged with developing and exploiting the unique capabilities of Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry, and leads the...

  2. Present and future superconducting cyclotrons

    International Nuclear Information System (INIS)

    Nolen, J.A. Jr.

    1987-01-01

    This paper begins with a brief review of the status of present superconducting (SC) cyclotron projects, including the two which are currently operating and the six which are under construction. The next section summarizes the main features shared by five of these machines, while the third section presents recent developments and new concepts introduced in the other three ''second generation'' SC cyclotrons. Projects in early stages of development are discussed in the fourth section

  3. Injection and extraction for cyclotrons

    International Nuclear Information System (INIS)

    Heikkinen, P.

    1994-01-01

    External ion sources for cyclotrons are needed for polarised and heavy ions. This calls for injection systems, either radial or axial. Radial injection is also needed when a cyclotron works as a booster after another cyclotron or a linear accelerator (usually tandem). Requirements for injection differ from separated sector cyclotrons where there is plenty of room to house inflectors and/or strippers, to superconducting cyclotrons where the space is limited by a small magnet gap, and high magnetic field puts other limitations to the inflectors. Several extraction schemes are used in cyclotrons. Stripping injection is used for H - and also for heavy ions where the q/m ratio is usually doubled. For other cases, electric and magnetic deflection has to be used. To increase the turn separation before the first deflector, both resonant and non-resonant schemes are used. In this lecture, external injection systems are surveyed and some rules to thumb for injection parameters are given. Extraction schemes are also reviewed. (orig.)

  4. National emergency medical assistance program for commercial nuclear power plants

    International Nuclear Information System (INIS)

    Linnemann, R.E.; Berger, M.E.

    1987-01-01

    Radiation Management Consultant's Emergency Medical Assistance Program (EMAP) for nuclear facilities provides a twenty-four hour emergency medical and health physics response capability, training of site and off-site personnel, and three levels of care for radiation accident victims: first air and rescue at an accident site, hospital emergency assessment and treatment, and definitive evaluation and treatment at a specialized medical center. These aspects of emergency preparedness and fifteen years of experience in dealing with medical personnel and patients with real or suspected radiation injury will be reviewed

  5. Solid targets for production of radioisotopes with cyclotron

    International Nuclear Information System (INIS)

    Paredes G, L.; Balcazar G, M.

    1999-01-01

    The design of targets for production of radioisotopes and radiopharmaceuticals of cyclotron to medical applications requires a detailed analysis of several variables such as: cyclotron operation conditions, choice of used materials as target and their physicochemical characteristics, activity calculation, the yielding of each radioisotope by irradiation, the competition of nuclear reactions in function of the projectiles energy and the collision processes amongst others. The objective of this work is to determine the equations for the calculation for yielding of solid targets at the end of the proton irradiation. (Author)

  6. Prevalence of At-Risk Drinking among a National Sample of Medical Students

    Science.gov (United States)

    Shah, Ameet Arvind; Bazargan-Hejazi, Shahrzad; Lindstrom, Richard W.; Wolf, Kenneth E.

    2009-01-01

    As limited research exists on medical students' substance use patterns, including over-consumption of alcohol, the objective of this study was to determine prevalence and correlates of at-risk drinking among a national sample of medical students, using a cross-sectional, anonymous, Web-based survey. A total of 2710 medical students from 36 U.S.…

  7. Multicavity proton cyclotron accelerator

    Directory of Open Access Journals (Sweden)

    J. L. Hirshfield

    2002-08-01

    Full Text Available A mechanism for acceleration of protons is described, in which energy gain occurs near cyclotron resonance as protons drift through a sequence of rotating-mode TE_{111} cylindrical cavities in a strong nearly uniform axial magnetic field. Cavity resonance frequencies decrease in sequence from one another with a fixed frequency interval Δf between cavities, so that synchronism can be maintained between the rf fields and proton bunches injected at intervals of 1/Δf. An example is presented in which a 122 mA, 1 MeV proton beam is accelerated to 961 MeV using a cascade of eight cavities in an 8.1 T magnetic field, with the first cavity resonant at 120 MHz and with Δf=8 MHz. Average acceleration gradient exceeds 40 MV/m, average effective shunt impedance is 223 MΩ/m, but maximum surface field in the cavities does not exceed 7.2 MV/m. These features occur because protons make many orbital turns in each cavity and thus experience acceleration from each cavity field many times. Longitudinal and transverse stability appear to be intrinsic properties of the acceleration mechanism, and an example to illustrate this is presented. This acceleration concept could be developed into a proton accelerator for a high-power neutron spallation source, such as that required for transmutation of nuclear waste or driving a subcritical fission burner, provided a number of significant practical issues can be addressed.

  8. Tachyonic cyclotron radiation

    International Nuclear Information System (INIS)

    Tomaschitz, R.

    2006-01-01

    We study superluminal cyclotron emission by electrons and muons in semiclassical orbits. The tachyonic line spectra of hydrogenic ions such as H, 56 Fe 25+ , and 238 U 91+ , as well as their muonic counterparts pμ - , 56 Fe 26+ μ - and 238 U 92+ μ - are calculated, in particular the tachyonic power transversally and longitudinally radiated, the total intensity, and the power radiated in the individual harmonics. We also investigate tachyonic continuum radiation from electrons and protons cycling in the surface and light cylinder fields of γ -ray and millisecond pulsars, such as the Crab pulsar, PSR B1509-58, and PSR J0218 + 4232. The superluminal spectral densities generated by non-relativistic, mildly relativistic and ultra-relativistic source particles are derived. We study the parameters determining the global shape of the transversal and longitudinal densities and the energy scales of the broadband spectrum. The observed cutoff frequency in the γ-ray band of the pulsars is used to infer the upper edge of the orbital energy, and we conclude that electrons and nuclei cycling in the surface fields can reach energies beyond the ''ankle'' of the cosmic ray spectrum. This suggests γ-ray pulsars as sources of ultra-high energy cosmic rays. (orig.)

  9. Review of determinants of national medical leadership development

    NARCIS (Netherlands)

    Keijser, Wouter Alexander; Poorthuis, Max Bastiaan; Tweedie, Judith; Wilderom, Celeste P.M.

    2017-01-01

    Increasingly, physician engagement in management, quality and innovation is being recognised as vital, requiring ’medical leadership’ (ML) competencies. Besides numerous local institutional efforts and despite the high level of autonomy of the medical profession and the education of its members, in

  10. Radioisotope production by reactors and cyclotrons in Japan

    International Nuclear Information System (INIS)

    Murakami, Yukio

    1978-01-01

    Present status of radioisotope production in Japan and the increasing demand from various fields are generally reviewed. Future problems associated with the shortage of economical supply are also discussed. The first half of this report is devoted to general review of the increasing demand for various radioisotopes from increasing number of users. The present status and future trends of the distribution of users of specific radioisotopes and their demands are shown. The remaining half of this report reviews the production with reactors and cyclotrons. The Japanese reactors producing radioisotopes are limited to low flux (10 13 ) research reactors at JAERI. Some problems associated with the improvement of availability and with the organizational structure are discussed. As for the production with cyclotrons, available facilities and the method of production are explained in detail. For clinical use, especially for the production of short lived radioisotopes, the advantage of a small special purpose cyclotron at each medical organization is emphasized. (Aoki, K.)

  11. CAS CERN Accelerator School: Cyclotrons, linacs and their applications. Proceedings

    International Nuclear Information System (INIS)

    Turner, S.

    1996-01-01

    These proceedings present the lectures given at the eighth specialized course organized by the CERN Accelerator School (CAS), the topic this time being 'Cyclotrons, Linacs and Their Applications'. Following an introductory lecture on linacs, the fundamental features of electron, ion and induction linacs are described together with their RF systems and particle sources. Cyclotrons are then introduced followed by details of their different types, their magnet and RF design, and their injection and extraction systems, with a glance towards exotic and possible future machines. Chapters are then presented on the use of linacs and cyclotrons for medical, fission, fusion and material applications, as well as for isotope production. Finally, descriptions of the design of a radioisotope facility, the matching of accelerators to their task and the computational tools used in their design are included. (orig.)

  12. CAS CERN Accelerator School: Cyclotrons, linacs and their applications. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Turner, S [ed.

    1996-03-04

    These proceedings present the lectures given at the eighth specialized course organized by the CERN Accelerator School (CAS), the topic this time being `Cyclotrons, Linacs and Their Applications`. Following an introductory lecture on linacs, the fundamental features of electron, ion and induction linacs are described together with their RF systems and particle sources. Cyclotrons are then introduced followed by details of their different types, their magnet and RF design, and their injection and extraction systems, with a glance towards exotic and possible future machines. Chapters are then presented on the use of linacs and cyclotrons for medical, fission, fusion and material applications, as well as for isotope production. Finally, descriptions of the design of a radioisotope facility, the matching of accelerators to their task and the computational tools used in their design are included. (orig.).

  13. Risk assessment of 30 MeV cyclotron facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Gyo Seong; Lee, Jin Woo [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Kim, Chong Yeal [Dept. of Radiation Science and Technology, Chonbuk National University, Jeonju (Korea, Republic of)

    2017-03-15

    A cyclotron is a kind of particle accelerator that produces a beam of charged particles for the production of medical, industrial, and research radioisotopes. More than 30 cyclotrons are operated in Korea to produce 18F, an FDG synthesis at hospitals. A 30-MeV cyclotron was installed at ARTI (Advanced Radiation Technology Institute, KAERI) mainly for research regarding isotope production. In this study, we analyze and estimate the items of risk such as the problems in the main components of the cyclotron, the loss of radioactive materials, the leakage of coolant, and the malfunction of utilities, fres and earthquakes. To estimate the occurrence frequency in an accident risk assessment, five levels, i.e., Almost certain, Likely, Possible, Unlikely, and Rare, are applied. The accident consequence level is classified under four grades based on the annual permissible dose for radiation workers and the public in the nuclear safety law. The analysis of the accident effect is focused on the radioactive contamination caused by radioisotope leakage and radioactive material leakage of a ventilation filter due to a free. To analyze the risks, Occupation Safety and Health Acts is applied. In addition, action plans against an accident were prepared after a deep discussion among relevant researchers. In this acts, we will search for hazard and introduce the risk assessment for the research 30-MeV cyclotron facilities of ARTI.

  14. The PET / cyclotron facility at Putrajaya Hospital - an update

    International Nuclear Information System (INIS)

    Siti Najila Mohd Janib; Suzilawati Muhd Sarowi; Munira Shaikh Nasir; Zulkifli Mohamed Hashim

    2006-01-01

    Malaysia desire to have a cyclotron for nuclear medical use came into realisation recently with the establishment of a PET/Cyclotron Facility at Putrajaya Hospital. The testing and commissioning of the cyclotron, hot cells, QC equipment and PET/CT started on March 27, culminating in the first patient to be injected on May 10 2006. Three other patients were to be followed on May 15. The patients from both the Kuala Lumpur and Putrajaya Hospital were pre-selected by physicians from these hospitals. The 18 MeV cyclotron is capable of generating 16.4 MeV protons and 8.4 MeV deuterons. The cyclotron at Putrajaya has three targets (2 liquid and 1 gas) and is capable of producing 18 F-FDG and 18 F-DOPA. To complement this, the facility has 2 modules for FDG synthesis, 1 for F-DOPA and 1 for nucleophilic synthesis. The facility will be GMP compliant. For the first production for human use, the water-18 target was irradiated for 50 minutes at 20 mA to produce 1.3 Ci of F-18. At the end of synthesis, the activity of the FDG obtained was 600 mCi. The product was then injected to a 26-year-old female, with a suspected adenocarcinoma. (Author)

  15. Radiation protection problems by the operation of the cyclotron facility

    International Nuclear Information System (INIS)

    Durcik, M.; Nikodemova, D.

    1998-01-01

    The Cyclotron Center in Bratislava will consist of two cyclotrons. First - cyclotron DC-72 with maximal energy of 72 MV for protons for making experiments, for teaching process, for radioisotope production as 123 I and for neutron and proton therapy. Second - compact cyclotron with maximal proton energy of 18 MeV will be used for radioisotopes production for medical diagnosis as 1 *F (fluorodeoxyglucose), 81 Rb/ 81 Kr generator. This paper deals with the radiation protection problems by the operation of tis cyclotron facility as radiation protection of workers, monitoring plan, ventilation, safety lock and limitation and radiation monitoring. For proposed and continuing practices at the accelerator facility, the following general principles have to be fulfilled: (1) practices should produce sufficient benefit to offset the radiation detriment they case (justification); (2) the magnitude of the individual doses should be kept as low as achievable (optimization of protection); (3) individual exposures are subject to dose limits and some control of risk from potential exposures (dose and risk limits)

  16. Risk assessment of 30 MeV cyclotron facilities

    International Nuclear Information System (INIS)

    Jeong, Gyo Seong; Lee, Jin Woo; Kim, Chong Yeal

    2017-01-01

    A cyclotron is a kind of particle accelerator that produces a beam of charged particles for the production of medical, industrial, and research radioisotopes. More than 30 cyclotrons are operated in Korea to produce 18F, an FDG synthesis at hospitals. A 30-MeV cyclotron was installed at ARTI (Advanced Radiation Technology Institute, KAERI) mainly for research regarding isotope production. In this study, we analyze and estimate the items of risk such as the problems in the main components of the cyclotron, the loss of radioactive materials, the leakage of coolant, and the malfunction of utilities, fres and earthquakes. To estimate the occurrence frequency in an accident risk assessment, five levels, i.e., Almost certain, Likely, Possible, Unlikely, and Rare, are applied. The accident consequence level is classified under four grades based on the annual permissible dose for radiation workers and the public in the nuclear safety law. The analysis of the accident effect is focused on the radioactive contamination caused by radioisotope leakage and radioactive material leakage of a ventilation filter due to a free. To analyze the risks, Occupation Safety and Health Acts is applied. In addition, action plans against an accident were prepared after a deep discussion among relevant researchers. In this acts, we will search for hazard and introduce the risk assessment for the research 30-MeV cyclotron facilities of ARTI

  17. Electron-cyclotron-resonant-heated electron distribution functions

    International Nuclear Information System (INIS)

    Matsuda, Y.; Nevins, W.M.; Cohen, R.H.

    1981-01-01

    Recent studies at Lawrence Livermore National Laboratory (LLNL) with a bounce-averaged Fokker-Planck code indicate that the energetic electron tail formed by electron-cyclotron resonant heating (ECRH) at the second harmonic is not Maxwellian. We present the results of our bounce-averaged Fokker-Planck code along with some simple analytic models of hot-electron distribution functions

  18. Medical Tourism and the Libyan National Health Services

    OpenAIRE

    Taguri, Adel El

    2007-01-01

    Medical tourism is a term that is used frequently by the media and travel agencies as a catchall phrase to describe a process where people travel to other countries to obtain medical, dental, and/or surgical care [1,2]. Leisure aspects of traveling are usually included on such a medical travel trip [1]. The term is also used to describe a situation where doctors travel to other places to deliver services to endogenous populations [3].Many factors have led to the recent increase in popularity ...

  19. [Cyclotron based nuclear science

    International Nuclear Information System (INIS)

    1993-07-01

    The period 1 April 1992--31 March 1993 saw the initial runs of three new spectrometers, which constitute a major portion of the new detection capabilities developed for this facility. These devices are the Proton Spectrometer (PSP) (data from which are shown on the cover of this document), the Mass Achroniat Recoil Mass Spectrometer (MARS), and the Multipole Dipole Multipole (MDM) Particle Spectrometer. The ECR-K500 cyclotron combination operated 5,849 hours. The beam was on target 39% of this time. Studies of nuclear dynamics and nuclear thermodynamics using the neutron ball have come to fruition. A critical re-evaluation of the available data on the giant monopole resonance indicated that the incompressibility is not specified to a range smaller than 200--350 MeV by those data. New systematic experiments using the MDM spectrometer are now underway. The MEGA collaboration obtained the first data on the μ → eγ decay rate and determination of the Michel parameter in normal μ decay. Experiments appear to confirm the existence of monoenergetic pair peaks even for relatively low Z projectile -- Z target combinations. Studies of the (α,2α) knockout reaction indicate that this reaction may prove to be a valuable tool for determination of reaction rates of astrophysical interest. Theoretical work reported in this document ranges from nuclear structure calculations using the IBM-2 model to calculations of kaon production and the in-medium properties of the rho and phi mesons. Nuclear dynamics and exotic shapes and fragmentation modes of hot nuclei are also addressed. New measurements of x-ray emission from highly ionized ions, of molecular dissociation and of surface interactions are reported. The research is presented in nearly 50 brief summaries usually including data and references

  20. [Historical origins between National Medical Association of China and Boji Hospital in Guangzhou].

    Science.gov (United States)

    Liu, Pinming

    2015-09-01

    In 2015, National Medical Association of China, now being called the Chinese Medical Association, celebrates its centennial and Boji Hospital in Guangzhou ( also known as Canton Hospital, or the Canton Pok Tsai Hospital, and now Sun Yat-sen Memorial Hospital of Sun Yat-sen University ) marks its 180th anniversary. Three major historical events establish the role of Boji Hospital in the founding and development of the National Medical Association of China during the last 100 years, viz.: ①hosting and participating in the establishment of the Medical Missionary Association of China and its official journal: the China Medical Missionary Journal; ②holding the 11th scientific sessions of the National Medical Association of China; ③nominating Dr. Wu Lien-teh as a candidate for the Nobel Prize in Physiology or Medicine in 1935 by William Warder Cadbury, the president of Boji Hospital.

  1. Solid targets and irradiation facilities for production of diagnostic and therapeutic radionuclides at the Debrecen cyclotron

    International Nuclear Information System (INIS)

    Tarkanyi, F.; Ando, L.; Szucs, Z.; Mahunka, I.; Kovacs, Z.

    2000-01-01

    The MGC-20E (NIIEFA, Leningrad, USSR) variable energy compact cyclotron (k=20) was installed in ATOMKI (Debrecen, Hungary) in 1985. Protons, deuterons, 3 He- and α-particles can be accelerated with currents up to 300 μA for internal irradiation and up to 50 μA for external beams. The establishment of the Cyclotron Laboratory was partly supported by the International Atomic Energy Agency. The application of the cyclotron is multipurpose: basic nuclear research, application of activation technique for analytical and wear studies, application of intense fast neutron source for agro-biological, bio-medical application and for radiation damage test of electronic components, and finally radioisotope production for medical diagnostics and for other scientific and applied fields. The cyclotron laboratory has six target rooms, a radiochemistry laboratory and a medical unit equipped with PET

  2. Knowledge of medical students on National Health Care System: A French multicentric survey.

    Science.gov (United States)

    Feral-Pierssens, A-L; Jannot, A-S

    2017-09-01

    Education on national health care policy and costs is part of our medical curriculum explaining how our health care system works. Our aim was to measure French medical students' knowledge about national health care funding, costs and access and explore association with their educational and personal background. We developed a web-based survey exploring knowledge on national health care funding, access and costs through 19 items and measured success score as the number of correct answers. We also collected students' characteristics and public health training. The survey was sent to undergraduate medical students and residents from five medical universities between July and November 2015. A total of 1195 students from 5 medical universities responded to the survey. Most students underestimated the total amount of annual medical expenses, hospitalization costs and the proportion of the general population not benefiting from a complementary insurance. The knowledge score was not associated with medical education level. Three students' characteristics were significantly associated with a better knowledge score: male gender, older age, and underprivileged status. Medical students have important gaps in knowledge regarding national health care funding, coverage and costs. This knowledge was not associated with medical education level but with some of the students' personal characteristics. All these results are of great concern and should lead us to discussion and reflection about medical and public health training. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  3. Electron cyclotron harmonic wave acceleration

    Science.gov (United States)

    Karimabadi, H.; Menyuk, C. R.; Sprangle, P.; Vlahos, L.

    1987-01-01

    A nonlinear analysis of particle acceleration in a finite bandwidth, obliquely propagating electromagnetic cyclotron wave is presented. It has been suggested by Sprangle and Vlahos in 1983 that the narrow bandwidth cyclotron radiation emitted by the unstable electron distribution inside a flaring solar loop can accelerate electrons outside the loop by the interaction of a monochromatic wave propagating along the ambient magnetic field with the ambient electrons. It is shown here that electrons gyrating and streaming along a uniform, static magnetic field can be accelerated by interacting with the fundamental or second harmonic of a monochromatic, obliquely propagating cyclotron wave. It is also shown that the acceleration is virtually unchanged when a wave with finite bandwidth is considered. This acceleration mechanism can explain the observed high-energy electrons in type III bursts.

  4. Electron cyclotron harmonic wave acceleration

    International Nuclear Information System (INIS)

    Karimabadi, H.; Menyuk, C.R.; Sprangle, P.; Vlahos, L.; Salonika Univ., Greece)

    1987-01-01

    A nonlinear analysis of particle acceleration in a finite bandwidth, obliquely propagating electromagnetic cyclotron wave is presented. It has been suggested by Sprangle and Vlahos in 1983 that the narrow bandwidth cyclotron radiation emitted by the unstable electron distribution inside a flaring solar loop can accelerate electrons outside the loop by the interaction of a monochromatic wave propagating along the ambient magnetic field with the ambient electrons. It is shown here that electrons gyrating and streaming along a uniform, static magnetic field can be accelerated by interacting with the fundamental or second harmonic of a monochromatic, obliquely propagating cyclotron wave. It is also shown that the acceleration is virtually unchanged when a wave with finite bandwidth is considered. This acceleration mechanism can explain the observed high-energy electrons in type III bursts. 31 references

  5. Status Report on Cyclotron Operation

    International Nuclear Information System (INIS)

    Kovacs, P.; Szuecs, I.; Ander, I.; Lakatos, T.; Tarkanyi, F.

    2004-01-01

    Complete text of publication follows. The operation of the cyclotron in 2004 was concentrated to the usual 9 months; January, July and August were reserved for maintenance and holidays. The overall working time of the accelerator was 3554 hours, the time used for systematic maintenance was 450 hours. The breakdown periods amounted to 70 hours last year, included in it a 50 hours repair of RF control module under guarantee. The cyclotron was available for users during 3034 hours. The effectively used beam-on-target time statistics is summarized in Table 1. Developments: A new measuring site with a HPGe detector based gamma spectrometer is under installation in the basement of the Cyclotron Laboratory. A two channel pneumatic rabbit system is also under development to enable fast transport of samples between the new measuring site and two irradiation sites (the low intensity fast neutron irradiation site and the beam line used for Thin Layer Activation). (author)

  6. Medical revivalism and the national movement in british India.

    Science.gov (United States)

    Bala, P

    1990-07-01

    The author discusses here the efforts made to revive Ayurveda in the twentieth century by the protagonists of Ayurveda during the national movement and appraises how far political support and State patronage did good for the recrudescence of Ayurveda.

  7. Comparing adults who use cannabis medically with those who use recreationally: Results from a national sample.

    Science.gov (United States)

    Lin, Lewei A; Ilgen, Mark A; Jannausch, Mary; Bohnert, Kipling M

    2016-10-01

    Cannabis has been legalized for medical use in almost half of the states in the U.S. Although laws in these states make the distinction between medical and recreational use of cannabis, the prevalence of people using medical cannabis and how distinct this group is from individuals using cannabis recreationally is unknown at a national level. Data came from the 2013 National Survey on Drug Use and Health (NSDUH). All adults endorsing past year cannabis use who reported living in a state that had legalized medical cannabis were divided into recreational cannabis use only and medical cannabis use. Demographic and clinical characteristics were compared across these two groups. 17% of adults who used cannabis in the past year used cannabis medically. There were no significant differences between those who used medically versus recreationally in race, education, past year depression and prevalence of cannabis use disorders. In adjusted analyses, those with medical cannabis use were more likely to have poorer health and lower levels of alcohol use disorders and non-cannabis drug use. A third of those who reported medical cannabis use endorsed daily cannabis use compared to 11% in those who reported recreational use exclusively. Adults who use medical and recreational cannabis shared some characteristics, but those who used medical cannabis had higher prevalence of poor health and daily cannabis use. As more states legalize cannabis for medical use, it is important to better understand similarities and differences between people who use cannabis medically and recreationally. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. An overview of intravenous-related medication administration errors as reported to MEDMARX, a national medication error-reporting program.

    Science.gov (United States)

    Hicks, Rodney W; Becker, Shawn C

    2006-01-01

    Medication errors can be harmful, especially if they involve the intravenous (IV) route of administration. A mixed-methodology study using a 5-year review of 73,769 IV-related medication errors from a national medication error reporting program indicates that between 3% and 5% of these errors were harmful. The leading type of error was omission, and the leading cause of error involved clinician performance deficit. Using content analysis, three themes-product shortage, calculation errors, and tubing interconnectivity-emerge and appear to predispose patients to harm. Nurses often participate in IV therapy, and these findings have implications for practice and patient safety. Voluntary medication error-reporting programs afford an opportunity to improve patient care and to further understanding about the nature of IV-related medication errors.

  9. Bedside ultrasound education in Canadian medical schools: A national survey

    Directory of Open Access Journals (Sweden)

    Peter Steinmetz

    2016-04-01

    Results:  Approximately half of the 13 responding medical schools had integrated bedside ultrasound teaching into their undergraduate curriculum. The most common trends in undergraduate ultrasound teaching related to duration (1-5 hours/year in 50% of schools, format (practical and theoretical in 67% of schools, and logistics (1:4 instructor to student ratio in 67% of schools. The majority of responding vice-deans indicated that bedside ultrasound education should be integrated into the medical school curriculum (77%, and cited a lack of ultrasound machines and infrastructure as barriers to integration. Conclusions: This study documents the current characteristics of undergraduate ultrasound education in Canada.

  10. Medical clerks in a national university hospital: improving the quality of medical care with a focus on spinal surgery.

    Science.gov (United States)

    Kobayashi, Kazuyoshi; Ando, Kei; Noda, Makiko; Ishiguro, Naoki; Imagama, Shiro

    2018-02-01

    In our institution, which is a national university hospital, medical clerks were introduced in 2009 to improve the doctor's working environment. Seventeen clerks were assigned to 9 separate departments and the work content differed greatly among departments, but sufficient professional work was not done efficiently. The purpose of this study is to investigate the effects of the work of medical clerks on improvement of medical quality in recent years. In 2011, we established a central clerk desk on our outpatient floor to improve efficiency and centralize the clerk work. Since 2013, periodic education of clerks on spine disease has been provided by spine doctors, and this has facilitated sharing of information on spinal surgery from diagnosis to surgical treatment. This has allowed medical clerks to ask patients questions, leading to more efficient medical treatment and a potential reduction of doctors' work. In 2016, a revision of the insurance system by the Ministry of Health, Labour and Welfare of Japan increased the amount of medical work that clerks can perform, and it became possible to increase the number of medical clerks. Currently, we have 30 medical clerks, and this has allowed establishment of new clerk desks in other departments to handle patients. A training curriculum will be developed to reduce the burden on doctors further and to improve the quality of medical treatment.

  11. Adherence to the Australian National Inpatient Medication Chart: the efficacy of a uniform national drug chart on improving prescription error.

    Science.gov (United States)

    Atik, Alp

    2013-10-01

    In 2006, the National Inpatient Medication Chart (NIMC) was introduced as a uniform medication chart in Australian public hospitals with the aim of reducing prescription error. The rate of regular medication prescription error in the NIMC was assessed. Data was collected using the NIMC Audit Tool and analyzed with respect to causes of error per medication prescription and per medication chart. The following prescription requirements were assessed: date, generic drug name, route of administration, dose, frequency, administration time, indication, signature, name and contact details. A total of 1877 medication prescriptions were reviewed. 1653 prescriptions (88.07%) had no contact number, 1630 (86.84%) did not have an indication, 1230 and 675 (35.96%) used a drug's trade name. Within 261 medication charts, all had at least one entry, which did not include an indication, 258 (98.85%) had at least one entry, which did not have a contact number and 200 (76.63%) had at least one entry, which used a trade name. The introduction of a uniform national medication chart is a positive step, but more needs to be done to address the root causes of prescription error. © 2012 John Wiley & Sons Ltd.

  12. MC-50 AVF cyclotron operation

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Jong Seo; Lee, Dong Hoon; Kim, You Seok; Park, Chan Won; Lee, Yong Min; Hong, Sung Seok; Lee, Min Yong

    1995-12-01

    The first cyclotron in Korea, MC-59 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-70 .mu.A. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed. (author). 8 tabs., 17 figs., 10 refs.

  13. MC-50 AVF cyclotron operation

    International Nuclear Information System (INIS)

    Kim, Yu Seok; Chai, Jong Seo; Bak, Seong Ki; Park, Chan Won; Jo, Young Ho; Hong, Seong Seok; Lee, Min Yong; Jang Ho Ha

    2000-01-01

    The first cyclotron in Korea, MC-50 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-60μA. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23 days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed

  14. MC-50 AVF cyclotron operation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yu Seok; Chai, Jong Seo; Bak, Seong Ki; Park, Chan Won; Jo, Young Ho; Hong, Seong Seok; Lee, Min Yong; Jang Ho Ha

    2000-01-01

    The first cyclotron in Korea, MC-50 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-60{mu}A. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23 days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed.

  15. The development of cyclotron radiopharmaceuticals

    International Nuclear Information System (INIS)

    Yang, Seung Dae; Chun, K. W.; Suh, Y. S.; Lee, J. D.; Ahn, S. H. and others

    1999-03-01

    The purpose of this project is to develop the radiopharmaceuticals and automatic synthetic unit for labelled compounds, and to establish mass production system of radiopharmaceuticals. These will contribute to the early diagnosis of the disease hard to cure. The contents of this project are as follows, the development of the radiopharmaceutical for imaging of cancer, the development of automatic synthesizer for the synthesis of radio-pharmaceuticals, the development of hormone derivatives labelled with 12 '3I, the development of the radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for imaging of myocardial metabolism

  16. MC-50 AVF cyclotron operation

    International Nuclear Information System (INIS)

    Chae, Jong Seo; Lee, Dong Hoon; Kim, You Seok; Park, Chan Won; Lee, Yong Min; Hong, Sung Seok; Lee, Min Yong.

    1995-12-01

    The first cyclotron in Korea, MC-59 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-70 .mu.A. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed. (author). 8 tabs., 17 figs., 10 refs

  17. The Implementation of Medical Informatics in the National Competence Based Catalogue of Learning Objectives for Undergraduate Medical Education (NKLM).

    Science.gov (United States)

    Behrends, Marianne; Steffens, Sandra; Marschollek, Michael

    2017-01-01

    The National Competence Based Catalogue of Learning Objectives for Undergraduate Medical Education (NKLM) describes medical skills and attitudes without being ordered by subjects or organs. Thus, the NKLM enables systematic curriculum mapping and supports curricular transparency. In this paper we describe where learning objectives related to Medical Informatics (MI) in Hannover coincide with other subjects and where they are taught exclusively in MI. An instance of the web-based MERLIN-database was used for the mapping process. In total 52 learning objectives overlapping with 38 other subjects could be allocated to MI. No overlap exists for six learning objectives describing explicitly topics of information technology or data management for scientific research. Most of the overlap was found for learning objectives relating to documentation and aspects of data privacy. The identification of numerous shared learning objectives with other subjects does not mean that other subjects teach the same content as MI. Identifying common learning objectives rather opens up the possibility for teaching cooperations which could lead to an important exchange and hopefully an improvement in medical education. Mapping of a whole medical curriculum offers the opportunity to identify common ground between MI and other medical subjects. Furthermore, in regard to MI, the interaction with other medical subjects can strengthen its role in medical education.

  18. The National Center for Collaboration in Medical Modeling and Simulation

    Science.gov (United States)

    2005-05-01

    being developed that addressed specific procedures including knee surgery, ophthalmology , and sinus surgery (Satava, 2001). One of the important factors...Nirona, 1990). In fact, the general picture for Vietnam data suggested that the prevalence of some types of disease may decrease during wartime...physical models with limited functionality. However, the current breed of medical simulators is quite sophisticated and many have impressive levels

  19. Next customers to cyclotron center meanwhile are not entered

    International Nuclear Information System (INIS)

    Bato, R.; Zackova, K.

    2004-01-01

    In this paper the financial aspects of construction of the Cyclotron Centre of the Slovak Republic (CC SR) are analysed. This building represents the problems of exploitation of commodity deblocation of Russian Federation debt to Slovakia. The estimated expenses have risen from original planned 2 billion Slovak crowns to 6 billion Slovak crowns. Devices which should be part of centre - a cyclotron used for radiopharmaceuticals production for oncological purposes and a big cyclotron for industrial purposes, a centre of positron emissive tomography (PET), a laboratory of nano-technologies, a source of heavy ions - they indicates that the oncological institutes, departments of health service, of education, of economy, of defence, of environment, also Nuclear Regulatory Authority of Slovak Republic and Slovak Academy of Sciences should become the customers principally. Around 2.2 billion of Slovak crowns from deblocation have been spent for a construction of Cyclotron Centre of SR yet. The national budget has contributed by 95 million Slovak crowns; 90.5 million USD will be obtained from deblocation of Russian debt yet. IAEA has supported this centre by grant of almost 800 thousand USD. Budget of Cyclotron Centre of SR is still rising also because of rising of VAT from 10 percent to 19 percent. VAT will be paid also for goods imported within the framework of deblocation after integration of Slovak Republic to European Union; besides also 10 percent duty is paid. Project of CC SR has not passed the state expert opinion. Agreement for construction of Cyclotron Centre of SR was issued by State Health Institute of Bratislava, therefore it was confirmed also by the main hygienist of Slovak Republic

  20. [Issues related to national university medical schools: focusing on the low wages of university hospital physicians].

    Science.gov (United States)

    Takamuku, Masatoshi

    2015-01-01

    University hospitals, bringing together the three divisions of education, research, and clinical medicine, could be said to represent the pinnacle of medicine. However, when compared with physicians working at public and private hospitals, physicians working at university hospitals and medical schools face extremely poor conditions. This is because physicians at national university hospitals are considered to be "educators." Meanwhile, even after the privatization of national hospitals, physicians working for these institutions continue to be perceived as "medical practitioners." A situation may arise in which physicians working at university hospitals-performing top-level medical work while also being involved with university and postgraduate education, as well as research-might leave their posts because they are unable to live on their current salaries, especially in comparison with physicians working at national hospitals, who focus solely on medical care. This situation would be a great loss for Japan. This potential loss can be prevented by amending the classification of physicians at national university hospitals from "educators" to "medical practitioners." In order to accomplish this, the Japan Medical Association, upon increasing its membership and achieving growth, should act as a mediator in negotiations between national university hospitals, medical schools, and the government.

  1. Princeton Cyclotron QDDD spectrograph system

    International Nuclear Information System (INIS)

    Kouzes, R.T.

    1985-01-01

    A review of experiments involving the Princeton Quadrupole-Dipole-Dipole- Dipole (QDDD) spectrograph is given. The QDDD is a high resolution, large solid angle device which is combined with the azymuthally varying field (AVF) cyclotron. Some reactions involving 3 He beams are discussed

  2. Ion sources for cyclotron applications

    International Nuclear Information System (INIS)

    Leung, K.N.; Bachman, D.A.; McDonald, D.S.; Young, A.T.

    1992-07-01

    The use of a multicusp plasma generator as an ion source has many advantages. The development of both positive and negative ion beams based on the multicusp source geometry is presented. It is shown that these sources can be operated at steady state or cw mode. As a result they are very suitable for cyclotron operations

  3. Ponderomotive force near cyclotron resonance

    Energy Technology Data Exchange (ETDEWEB)

    Kono, Mitsuo; Sanuki, Heiji

    1987-01-01

    The ponderomotive force, which is involved in the excitation of macroscopic behaviors of plasma caused by wave motion, plays an important role in various non-linear wave motion phenomena. In the present study, equations for the pondermotive force for plasma in a uniform magnetic field is derived using a renormalization theory which is based on the Vlasov equation. It is shown that the pondermotive force, which diverges at the cyclotron resonence point according to adiabatic approximation, can be expressed by a non-divergent equation by taking into account the instability of the cyclotron orbit due to high-order scattering caused by a wave. This is related with chaotic particle behaviors near cyclotron resonance, where the pondermotive force is small and the diffusion process prevails. It is assumed here that the amplitude of the high-frequency electric field is not large and that the broadening of cyclotron levels is smaller than the distance between the levels. A global chaos will be created if the amplitude of the electric field becomes greater to allow the broadening to exceed the distance between the levels. (Nogami, K.).

  4. Cyclotron transitions of bound ions

    Science.gov (United States)

    Bezchastnov, Victor G.; Pavlov, George G.

    2017-06-01

    A charged particle in a magnetic field possesses discrete energy levels associated with particle rotation around the field lines. The radiative transitions between these levels are the well-known cyclotron transitions. We show that a bound complex of particles with a nonzero net charge displays analogous transitions between the states of confined motion of the entire complex in the field. The latter bound-ion cyclotron transitions are affected by a coupling between the collective and internal motions of the complex and, as a result, differ from the transitions of a "reference" bare ion with the same mass and charge. We analyze the cyclotron transitions for complex ions by including the coupling within a rigorous quantum approach. Particular attention is paid to comparison of the transition energies and oscillator strengths to those of the bare ion. Selection rules based on integrals of collective motion are derived for the bound-ion cyclotron transitions analytically, and the perturbation and coupled-channel approaches are developed to study the transitions quantitatively. Representative examples are considered and discussed for positive and negative atomic and cluster ions.

  5. Status report on cyclotron operation

    CERN Document Server

    Kovács, P; Ander, I; Lakatos, T; Fenyvesi, A; Ditrói, F; Takács, S; Tarkanyi, F

    2003-01-01

    The operation of the cyclotron in 2002 was concentrated to 9 months; January, July and August were reserved for maintenance and holidays. The overall working time of the accelerator was 4084 hours, the breakdown periods amounted to 15 hours last year. In order to improve the circumstances of the irradiations, several following improvements were done. (R.P.)

  6. Intelligent low-level RF system by non-destructive beam monitoring device for cyclotrons

    Science.gov (United States)

    Sharifi Asadi Malafeh, M. S.; Ghergherehchi, M.; Afarideh, H.; Chai, J. S.; Yoon, Sang Kim

    2016-04-01

    The project of a 10 MeV PET cyclotron accelerator for medical diagnosis and treatment was started at Amirkabir University of Technology in 2012. The low-level RF system of the cyclotron accelerator is designed to stabilize acceleration voltage and control the resonance frequency of the cavity. In this work an Intelligent Low Level Radio Frequency Circuit or ILLRF, suitable for most AVF cyclotron accelerators, is designed using a beam monitoring device and narrow band tunable band-pass filter. In this design, the RF phase detection does not need signal processing by a microcontroller.

  7. Modern compact cyclotrons for nuclear medicine designed and manufactured in NIIEFA

    International Nuclear Information System (INIS)

    Bogdanov, P.V.; Vasilchenko, I.N.; Gavrish, Yu.N.; Galchuk, A.V.; Grigorenko, S.V.; Kuzhlev, A.N.; Menshov, Yu.D.; Mudroyubov, V.G.; Ponomarenko, V.I.; Strokach, A.P.

    2012-01-01

    A series of compact cyclotrons, the CC-12, CC-18/9 and MCC-30/15, intended for the production of radionuclides for diagnostics and therapy directly in medical institutions has been designed and manufactured in NIIEFA. These cyclotrons provide the acceleration of negative hydrogen and deuterium ions injected from external sources. Beams of accelerated particles are extracted by stripping negative ions to protons and deuterons by carbon foils. Shielding-type electromagnets with the vertically located median plane are applied in these cyclotrons.

  8. Broadcast Advertising of Medical Products and Services: Its Regulation by Other Nations.

    Science.gov (United States)

    Powell, Jon T.

    1972-01-01

    Restraints imposed on medical advertising through the broadcast media reflect a worldwide concern for public protection in a sensitive area, where problems of ignorance and misrepresentation are enlarged by false hope. The author examines the broadcast codes of seventeen free-world nations, with respect to their provisions on medical advertising.…

  9. 76 FR 19104 - National Institute of General Medical Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2011-04-06

    ... General Medical Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory... clearly unwarranted invasion of personal privacy. Name of Committee: National Institute of General Medical Sciences Special Emphasis Panel; 2011 NIH Director's Pioneer Awards. Date: May 2-4, 2011. Time: 7:45 a.m...

  10. 75 FR 65363 - National Institute of General Medical Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2010-10-22

    ... Sciences Special Emphasis Panel; Review of Minority Biomedical Research Neuro Grant Applications. Date... General Medical Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory... General Medical Sciences, National Institutes of Health, Natcher Building, Room 3AN18J, Bethesda, MD 20892...

  11. 75 FR 63843 - National Institute of General Medical Sciences; Notice of Closed Meeting

    Science.gov (United States)

    2010-10-18

    ... Sciences Special Emphasis Panel; Review of Minority Biomedical Research Neuro Grant Applications. Date... General Medical Sciences; Notice of Closed Meeting Pursuant to section 10(d) of the Federal Advisory... of General Medical Sciences, National Institutes of Health, Natcher Building, Room 3AN18J, Bethesda...

  12. Medical abortion practices : a survey of National Abortion Federation members in the United States

    NARCIS (Netherlands)

    Wiegerinck, Melanie M. J.; Jones, Heidi E.; O'Connell, Katharine; Lichtenberg, E. Steve; Paul, Maureen; Westhoff, Carolyn L.

    2008-01-01

    Background: Little is known about clinical implementation of medical abortion in the United States following approval of mifepristone as an abortifacient by the Food and Drug Administration (FDA) in 2000. We collected information regarding medical abortion practices of National Abortion Federation

  13. Medical abortion practices: a survey of National Abortion Federation members in the United States

    NARCIS (Netherlands)

    Wiegerinck, Melanie M. J.; Jones, Heidi E.; O'Connell, Katharine; Lichtenberg, E. Steve; Paul, Maureen; Westhoff, Carolyn L.

    2008-01-01

    Little is known about clinical implementation of medical abortion in the United States following approval of mifepristone as an abortifacient by the Food and Drug Administration (FDA) in 2000. We collected information regarding medical abortion practices of National Abortion Federation (NAF) members

  14. 76 FR 3918 - National Institute of General Medical Sciences; Amended Notice of Meeting

    Science.gov (United States)

    2011-01-21

    ... General Medical Sciences; Amended Notice of Meeting Notice is hereby given of a change in the meeting of the National Advisory General Medical Sciences Council, January 27, 2011, 8:30 a.m. to January 28... of Federal Advisory Committee Policy. [FR Doc. 2011-1198 Filed 1-20-11; 8:45 am] BILLING CODE 4140-01...

  15. Electron cyclotron heating calculations for ATF

    International Nuclear Information System (INIS)

    Goldfinger, R.C.; Batchelor, D.B.

    1986-03-01

    The RAYS geometrical optics code has been used to calculate electron cyclotron wave propagation and heating in the Advanced Toroidal Facility (ATF) device under construction at Oak Ridge National Laboratory (ORNL). The intent of this work is to predict the outcome of various heating scenarios and to give guidance in designing an optimum heating system. Particular attention is paid to the effects of wave polarization and antenna location. We investigate first and second harmonic cyclotron heating with the parameters predicted for steady-state ATF operation. We also simulate the effect of wall reflections by calculating a uniform, isotropic flux of power radiating from the wall. These results, combined with the first-pass calculations, give a qualitative picture of the heat deposition profiles. From these results we identify the compromises that represent the optimum heating strategies for the ATF model considered here. Our basic conclusions are that second harmonic heating with the extraordinary mode (X-mode) gives the best result, with fundamental ordinary mode (O-mode) heating being slightly less efficient. Assuming the antenna location is restricted to the low magnetic field side, the antenna should be placed at phi = 0 0 (the toroidal angle where the helical coils are at the sides) for fundamental heating and at phi = 15 0 (where the helical coils are at the top and bottom) for second harmonic heating. These recommendations come directly from the ray tracing results as well as from a theoretical identification of the relevant factors affecting the heating

  16. National Coal Board Medical Service annual report 1980-1981

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    Sections report on: medical examinations and consultations; protection from health hazards such as pneumoconiosis and other prescribed diseases; problems such as vitamin D in the blood of miners, Legionaires' disease, Perthe's disease, rehabilitation and physiotherapy, chemical hazards, public health and hygiene, noise, and the use of visual display units; diseases from coal products such as in coke and tar manufacture; first aid services, morphia, and nursing service; and back pain in the mining industry. A list of staff and their publications is also included.

  17. National electronic medical records integration on cloud computing system.

    Science.gov (United States)

    Mirza, Hebah; El-Masri, Samir

    2013-01-01

    Few Healthcare providers have an advanced level of Electronic Medical Record (EMR) adoption. Others have a low level and most have no EMR at all. Cloud computing technology is a new emerging technology that has been used in other industry and showed a great success. Despite the great features of Cloud computing, they haven't been utilized fairly yet in healthcare industry. This study presents an innovative Healthcare Cloud Computing system for Integrating Electronic Health Record (EHR). The proposed Cloud system applies the Cloud Computing technology on EHR system, to present a comprehensive EHR integrated environment.

  18. Current heavy particle medical accelerator programs in Japan

    International Nuclear Information System (INIS)

    Kawachi, K.

    1987-01-01

    The first clinical trial of proton radiotherapy in Japan started at National Institute of Radiological Sciences (NIRS) in 1979. The proton which is provided from the NIRS medical cyclotron, has an energy of 70 MeV, and has been used for only superficial or short range tumor therapy. Recently, the cyclotron has been raised the energy up to 90 MeV and a vertical treatment line of protons has been completed in the basement of the cyclotron building. In 1983, Particle Radiation Medical Science Center (PARMS) of the University of Tsukuba started to treat patients with 250 MeV proton beam. The Institute of Physical and Chemical Research (IPCR) has a plan to construct a heavy ion biomedical irradiation facility in the Ring (Separate Sector) Cyclotron building. The facility will be completed in 1989 and will be used for proton and helium ion therapy. Recently, several hospitals have proposed to construct the dedicated proton therapy facilities. The National Cancer Center of Japan, and the PARMS of the University of Tsukuba have taken active parts in such projects. At present time, there is a step to make a decision of the type of accelerators. Another program is a construction of the NIRS Heavy Particle Medical Accelerator which is possible to provide Helium to Argon ions for therapy. The paper describes the accelerators for proton therapy and for heavy ion therapy in some detail

  19. Antidepressant medication use for primary care patients with and without medical comorbidities: a national electronic health record (EHR) network study.

    Science.gov (United States)

    Gill, James M; Klinkman, Michael S; Chen, Ying Xia

    2010-01-01

    Because comorbid depression can complicate medical conditions (eg, diabetes), physicians may treat depression more aggressively in patients who have these conditions. This study examined whether primary care physicians prescribe antidepressant medications more often and in higher doses for persons with medical comorbidities. This secondary data analysis of electronic health record data was conducted in the Centricity Health Care User Research Network (CHURN), a national network of ambulatory practices that use a common outpatient electronic health record. Participants included 209 family medicine and general internal medicine providers in 40 primary care CHURN offices in 17 US states. Patients included adults with a new episode of depression that had been diagnosed during the period October 2006 through July 2007 (n = 1513). Prescription of antidepressant medication and doses of antidepressant medication were compared for patients with and without 6 comorbid conditions: diabetes, coronary heart disease, congestive heart failure, cerebrovascular disease, chronic obstructive pulmonary disease, and cancer. 20.7% of patients had at least one medical comorbidity whereas 5.8% had multiple comorbidities. Overall, 77% of depressed patients were prescribed antidepressant medication. After controlling for age and sex, patients with multiple comorbidities were less likely to be prescribed medication (adjusted odds ratio, 0.58; 95% CI, 0.35-0.96), but there was no significant difference by individual comorbidities. Patients with cerebrovascular disease were less likely to be prescribed a full dose of medication (adjusted odds ratio, 0.26; 95% CI, 0.08-0.88), but there were no differences for other comorbidities or for multiple comorbidities, and there was no difference for any comorbidities in the prescription of minimally effective doses. Patients with new episodes of depression who present to a primary care practice are not treated more aggressively if they have medical

  20. [Medical thinking and ways of acting in national socialism].

    Science.gov (United States)

    Degkwitz, R

    1985-06-01

    The historical background of the legislative measures to purify the Germanic race and the "practical measures to strengthen the German people" is the biologistic way of thinking in the 19th century. This evolved from Darwinism, leading to the so-called Social Darwinism. Its final consequence was the murdering of "inferior" human beings, which included murdering mentally ill and mentally retarded people. The latter is extensively described in recent literature and is usually considered as a specifically National Socialist or psychiatric action. These view points are discussed, and the literature on this subject is thoroughly reviewed.

  1. Directory of cyclotrons used for radionuclide production in Member States [2006 update

    International Nuclear Information System (INIS)

    2006-10-01

    The present directory of cyclotron facilities used for the production of radionuclides in Member States is an update of the one compiled by the International Atomic Energy Agency (IAEA) in late 2001 and published in 2002. This directory was prepared through information collected by questionnaires that the IAEA sent to known institutions operating cyclotrons for radionuclide production. Technical as well as administrative data supplied to the IAEA as of November 2005 were taken into account. The directory is considered to include most of the cyclotrons of the world that are used at least partially for radionuclide production. There are 262 entries for cyclotrons operating in 39 Member States of the IAEA. This is an increase of 7% over the 246 reported in the 2002 cyclotron directory. This can be compared to the 350 or so cyclotrons believed to be presently operating in the world, which are involved in some aspects of radionuclide production. The increase has been in the number of cyclotrons in developed countries, but even more so in the developing countries. The increase in number during the last four years was driven by several factors, i.e. advent of advances in medical imaging, introduction of compact, user friendly medical cyclotron, and a recent decision that costs for 15 O-oxygen position emission tomography (PET) studies in Japan and 18 F-FDG PET studies in Germany and the United States of America are eligible for reimbursement by government or health insurance companies. There is no doubt that the fastest growing segment of the market is in the commercial distribution of FDG to local hospitals. The IAEA is promoting cyclotron technology as applied to nuclear medicine. Requests for cyclotron technology is steadily increasing; many developing Member States are interested in this technology. There is need to stimulate, build and maintain consulting capability in interested developing Member States. There are good reasons to believe that the number of cyclotron

  2. Calculation of the neutrons shielding in cyclotron accelerator

    International Nuclear Information System (INIS)

    Ribeiro, Martha S.; Sanches, Matias P.; Rodrigues, Demerval L.

    2000-01-01

    The objective of radioprotection in cyclotron facilities is to reduce the dose levels in the workplaces to classify them like supervised areas. In this way, the radiation dose rates in areas occupied by workers during cyclotron operations should not exceed 7,5 μSv/h. In controlled areas these levels are not observed and some rigorous controls must be exerted by administrative procedures or protection mechanisms. The Cyclotron Laboratory at IPEN-CNEN/SP has a cyclotron model Cyclone 30, 30 MeV, used for research and it is also used for radioisotopes production for medical diagnosis and therapeutical applications. Among them, 123 I, 67 Ga and 18 F can be pointed. When accelerator is operating, failures in perforations and paths that conduce to room accelerator can be occur and thus, the dose levels are higher than that established by law. For this reason, a review for shielding structure was necessary in order to optimize radiation dose. The purpose of this work was to determine the shielding thickness and adequate material to diminish the dose rates in workplaces to a value below 7,5 μSv/h. It was used a method to employ the equivalent dose value in the facility areas for neutrons fluency rate for the principal reactions in target irradiation processes. The purposed shielding for the vault doors ensures dose levels lower than established limits to supervised areas. (author)

  3. Cyclotron for medicine and research; Zyklotron fuer Medizin und Forschung

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2012-11-01

    35 tons, weighs the major medical device, which has been delivered in early may at the Julic campus. A heavy-duty crane hoisted the new compact cyclotron to its destination, an underground concrete bunker. There it will from summer 2013 produce radionuclides for the synthesis of radiopharmaca, by which it is possible among others to detect tumors, to pursue metabolic processes, and to investigate the mechanisms of action of drugs.

  4. Cyclotron Production of Technetium-99m

    Science.gov (United States)

    Gagnon, Katherine M.

    Technetium-99m (99mTc) has emerged as the most widely used radionuclide in medicine and is currently obtained from a 99Mo/ 99mTc generator system. At present, there are only a handful of ageing reactors worldwide capable of producing large quantities of the parent isotope, 99Mo, and owing to the ever growing shutdown periods for maintenance and repair of these ageing reactors, the reliable supply 99mTc has been compromised in recent years. With an interest in alternative strategies for producing this key medical isotope, this thesis focuses on several technical challenges related to the direct cyclotron production of 99mTc via the 100Mo(p,2n)99mTc reaction. In addition to evaluating the 100Mo(p,2n)99mTc and 100Mo(p,x)99Mo reactions, this work presented the first experimental evaluation of the 100Mo(p,2n) 99gTc excitation function in the range of 8-18 MeV. Thick target calculations suggested that large quantities of cyclotron-produced 99mTc may be possible. For example, a 6 hr irradiation at 500 μA with an energy window of 18→10 MeV is expected to yield 1.15 TBq of 99mTc. The level of coproduced 99gTc contaminant was found to be on par with the current 99Mo/99mTc generator standard eluted with a 24 hr frequency. Highly enriched 100Mo was required as the target material for 99mTc production and a process for recycling of this expensive material is presented. An 87% recovery yield is reported, including metallic target preparation, irradiation, 99mTc extraction, molybdate isolation, and finally hydrogen reduction to the metal. Further improvements are expected with additional optimization experiments. A method for forming structurally stable metallic molybdenum targets has also been developed. These targets are capable of withstanding more than a kilowatt of beam power and the reliable production and extraction of Curie quantities of 99mTc has been demonstrated. With the end-goal of using the cyclotron-produced 99mTc clinically, the quality of the cyclotron

  5. German MedicalTeachingNetwork (MDN) implementing national standards for teacher training.

    Science.gov (United States)

    Lammerding-Koeppel, M; Ebert, T; Goerlitz, A; Karsten, G; Nounla, C; Schmidt, S; Stosch, C; Dieter, P

    2016-01-01

    An increasing demand for proof of professionalism in higher education strives for quality assurance (QA) and improvement in medical education. A wide range of teacher trainings is available to medical staff in Germany. Cross-institutional approval of individual certificates is usually a difficult and time consuming task for institutions. In case of non-acceptance it may hinder medical teachers in their professional mobility. The faculties of medicine aimed to develop a comprehensive national framework, to promote standards for formal faculty development programmes across institutions and to foster professionalization of medical teaching. Addressing the above challenges in a joint approach, the faculties set up the national MedicalTeacherNetwork (MDN). Great importance is attributed to work out nationally concerted standards for faculty development and an agreed-upon quality control process across Germany. Medical teachers benefit from these advantages due to portability of faculty development credentials from one faculty of medicine to another within the MDN system. The report outlines the process of setting up the MDN and the national faculty development programme in Germany. Success factors, strengths and limitations are discussed from an institutional, individual and general perspective. Faculties engaged in similar developments might be encouraged to transfer the MDN concept to their countries.

  6. Neutron radiography with the cyclotron

    International Nuclear Information System (INIS)

    Tazawa, Shuichi; Asada, Yorihisa; Yano, Munehiko; Nakanii, Takehiko.

    1985-01-01

    Neutron radiography is well recognized as a powerful tool in nondestructive testing, but not widely used yet owing to lack of high intense thermal neutron source convenient for practical use. This article presents a new neutron radiograph facility, utilizing a sub-compact cyclotron as neutron source and is equipped with vertical and horizontal irradiation ports. The article describes a series of experiments, we conducted using beams of a variable energy cyclotron at Tohoku University to investigate the characteristics of thermal neutron obtained from 9 Be(p, n) reaction and thermalized by elastic scattering process. The article also describes a computer simulation of neutron moderator to analyze conditions getting maximal thermal neutron flux. Further, some of practical neutron radiograph examinations of aero-space components and museum art objects of classic bronze mirror and an attempt realizing real time imaging technique, are introduced in the article. (author)

  7. The development of cyclotron radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Dae; Chun, K. W.; Suh, Y. S.; Lee, J. D.; Ahn, S. H. and others

    1999-03-01

    The purpose of this project is to developthe radiopharmaceuticals and automatic synthetic unit for labelled compounds, and to establish mass production system of radiopharmaceuticals. These will contribute to the early diagnosis of the disease hard to cure. The contents of this project are as follows, the development of the radiopharmaceutical for imaging of cancer, the development of automatic synthesizer for the synthesis of radio-pharmaceuticals, the development of hormone derivatives labelled with {sup 12}'3I, the development of the radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for imaging of myocardial metabolism.

  8. Cyclotron radiation from hot plasmas

    International Nuclear Information System (INIS)

    Pohl, F.; Henning, J.; Duechs, D.

    1975-11-01

    In calculating the energy transport and losses due to cyclotron radiation there are two major requirements: the absorption coefficient has to be known and the proper geometry of the plasma has to be taken into account. In this report Trubnikov's integral formulae for the absorption coefficient have been evaluated numerically and compared with the approximative formulas of previous authors. Deviations by a factor of 2 - 10 in various frequency regimes are not unusual. With these coefficients the rate of change of the energy density due to cyclotron radiation in a plasma as well as the radiation density at a plasma surface are computed for plasma slab and plasma cylinder. Sometimes considerable differences to the results of previons papers can found. Many simple formulae interpolating the numerical results are given in the text, and the FORTRAN computer programs have been reproduced in the appendices. (orig.) [de

  9. Predictors of medication use in the Roma population in Spain: a population-based national study.

    Science.gov (United States)

    Martín-Pérez, M; Hernández Barrera, V; López de Andrés, A; Jiménez-Trujillo, I; Jiménez-García, R; Carrasco-Garrido, P

    2015-05-01

    To describe the prevalence of prescribed and self-medicated use of medication in the Spanish Roma population, and identify the associated factors. Descriptive cross-sectional study. Data from the first National Health Survey conducted on the Roma population in Spain were used. The sample comprised 1000 Spanish Roma adults of both sexes aged ≥16 years. Answers (yes/no) to the question, 'In the last two weeks have you taken the following medicines [in reference to a list of medicines that might be used by the population] and were they prescribed for you by a doctor?' were used to ascertain 'medication use'. 'Self-medication' referred to use of these medicines without medical prescription. Using multivariate logistic regression models, odds ratios (ORs) with 95% confidence intervals (CIs) were calculated to identify associated factors. The overall prevalence of medication use in the Roma population for both sexes was 69.1%, and 38.7% was self-medicated. Females reported higher use of medication than males (75.1% vs 62.3%); however, self-medication was higher among males. Analgesics and antipyretics were used most often (35.8%). Among males, the variables that were independently and significantly associated with a higher probability of medication use were: age; negative perception of health; presence of chronic disease (OR 2.81; 95% CI 1.67-4.73); and medical visits (OR 4.51; 95% CI 2.54-8.01). The variables were the same among females, except for age. A high percentage of the Spanish Roma population use medication, and a significant proportion of them self-medicate. The presence of chronic diseases, a negative perception of health and medical consultations were associated with increased use of medication in the study population. Copyright © 2015 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  10. Canadian National Guidelines and Recommendations for Integrating Career Advising Into Medical School Curricula.

    Science.gov (United States)

    Howse, Kelly; Harris, June; Dalgarno, Nancy

    2017-11-01

    Career planning, decision making about specialty choice, and preparation for residency matching are significant sources of stress for medical students. Attempts have been made to structure and formalize career advising by including it in accreditation standards. There is an expressed need for national guidelines on career advising for medical students. The Future of Medical Education in Canada Postgraduate (FMEC PG) Implementation Project was created to ensure Canadian medical trainees receive the best education possible. From this, a diverse sub-working group (SWG), representing different Canadian regions, was formed to review career advising processes across the country. The SWG developed, through a modified formal consensus methodology, a strategy for medical student career advising that is adaptable to all schools in alignment with existing accreditation standards. The SWG outlined five guiding principles and five essential elements for Canadian universities offering an MD degree with recommendations on how to integrate the elements into each school's career advising system. The five essential elements are a structured approach to career advising, information about available career options, elective guidance, preparation for residency applications, and social accountability. This Perspective endorses the view of the FMEC PG Implementation Project that national guidelines are important to ensure Canadian medical schools are consistently meeting accreditation standards by providing reliable and quality career advising to all medical students. The SWG's position, based on national and provincial feedback, is that these guidelines will stimulate discourse and action regarding the requirements and processes to carry out these recommendations nationwide and share across borders.

  11. Cyclotron production of Cu-61

    Czech Academy of Sciences Publication Activity Database

    Lebeda, Ondřej; Ráliš, Jan; Seifert, Daniel

    2013-01-01

    Roč. 40, 2 Supplement (2013), S323-S323 ISSN 1619-7070. [Annual Congress of the European Association of Nuclear Medicine (EANM). 19.10.2013-23.10.2013, Lyon] R&D Projects: GA TA ČR TA02010797 Institutional support: RVO:61389005 Keywords : cyclotron U-120M * PET * Cu-61 Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders

  12. Status report on the cyclotron

    International Nuclear Information System (INIS)

    Kormany, Z.

    2002-01-01

    Complete text of publication follows. The operation of the cyclotron in 2001 was again concentrated to the usual 9 months; January, July and August were reserved for maintenance and holidays. The overall working time of the accelerator was 4300 hours, the breakdown periods amounted to 66 hours last year. The cyclotron was available for users during 3751 hours, the effectively used beam-on-target time is summarized in Table 1. The total time required for machine setup and beam tuning or spent waiting for the start of an irradiation was 272 hours. The control of the adjustable collimators applied in the beam transport system of the cyclotron was renewed during the winter maintenance period. They have been connected to the programmable logic controllers (PLC) and their new control code frees the operators from the long and slow manual setting process. The successful renewal of the control of this and other subsystems (cyclotron and beam transport power supplies) made lots of adjusting and measuring elements on the original control desk needless. To provide more space for the control PCs and remove all unnecessary devices, the unused part of the control desk has been dismantled. The short beam line used mainly for radiation hardness studies was equipped with a new oil-diffusion vacuum system during the summer maintenance. Its components are also connected to the PLC and the same automatic control has been provided like for the other vacuum stands of- the beam transport system. Another short beam line - basically a mirror image of the first one - has also been installed and successfully tested by trial irradiations. (R.P.)

  13. The epidemiology and type of medication errors reported to the National Poisons Information Centre of Ireland.

    Science.gov (United States)

    Cassidy, Nicola; Duggan, Edel; Williams, David J P; Tracey, Joseph A

    2011-07-01

    Medication errors are widely reported for hospitalised patients, but limited data are available for medication errors that occur in community-based and clinical settings. Epidemiological data from poisons information centres enable characterisation of trends in medication errors occurring across the healthcare spectrum. The objective of this study was to characterise the epidemiology and type of medication errors reported to the National Poisons Information Centre (NPIC) of Ireland. A 3-year prospective study on medication errors reported to the NPIC was conducted from 1 January 2007 to 31 December 2009 inclusive. Data on patient demographics, enquiry source, location, pharmaceutical agent(s), type of medication error, and treatment advice were collated from standardised call report forms. Medication errors were categorised as (i) prescribing error (i.e. physician error), (ii) dispensing error (i.e. pharmacy error), and (iii) administration error involving the wrong medication, the wrong dose, wrong route, or the wrong time. Medication errors were reported for 2348 individuals, representing 9.56% of total enquiries to the NPIC over 3 years. In total, 1220 children and adolescents under 18 years of age and 1128 adults (≥ 18 years old) experienced a medication error. The majority of enquiries were received from healthcare professionals, but members of the public accounted for 31.3% (n = 736) of enquiries. Most medication errors occurred in a domestic setting (n = 2135), but a small number occurred in healthcare facilities: nursing homes (n = 110, 4.68%), hospitals (n = 53, 2.26%), and general practitioner surgeries (n = 32, 1.36%). In children, medication errors with non-prescription pharmaceuticals predominated (n = 722) and anti-pyretics and non-opioid analgesics, anti-bacterials, and cough and cold preparations were the main pharmaceutical classes involved. Medication errors with prescription medication predominated for adults (n = 866) and the major medication

  14. The epidemiology and type of medication errors reported to the National Poisons Information Centre of Ireland.

    LENUS (Irish Health Repository)

    Cassidy, Nicola

    2012-02-01

    INTRODUCTION: Medication errors are widely reported for hospitalised patients, but limited data are available for medication errors that occur in community-based and clinical settings. Epidemiological data from poisons information centres enable characterisation of trends in medication errors occurring across the healthcare spectrum. AIM: The objective of this study was to characterise the epidemiology and type of medication errors reported to the National Poisons Information Centre (NPIC) of Ireland. METHODS: A 3-year prospective study on medication errors reported to the NPIC was conducted from 1 January 2007 to 31 December 2009 inclusive. Data on patient demographics, enquiry source, location, pharmaceutical agent(s), type of medication error, and treatment advice were collated from standardised call report forms. Medication errors were categorised as (i) prescribing error (i.e. physician error), (ii) dispensing error (i.e. pharmacy error), and (iii) administration error involving the wrong medication, the wrong dose, wrong route, or the wrong time. RESULTS: Medication errors were reported for 2348 individuals, representing 9.56% of total enquiries to the NPIC over 3 years. In total, 1220 children and adolescents under 18 years of age and 1128 adults (>\\/= 18 years old) experienced a medication error. The majority of enquiries were received from healthcare professionals, but members of the public accounted for 31.3% (n = 736) of enquiries. Most medication errors occurred in a domestic setting (n = 2135), but a small number occurred in healthcare facilities: nursing homes (n = 110, 4.68%), hospitals (n = 53, 2.26%), and general practitioner surgeries (n = 32, 1.36%). In children, medication errors with non-prescription pharmaceuticals predominated (n = 722) and anti-pyretics and non-opioid analgesics, anti-bacterials, and cough and cold preparations were the main pharmaceutical classes involved. Medication errors with prescription medication predominated for

  15. Standardized high current solid targets for cyclotron production of radionuclides

    International Nuclear Information System (INIS)

    Al-Jammaz, Ibrahim

    2000-01-01

    The Cyclotron and Radiopharmaceuticals Department (CRP) is an advanced and modern facility that encompasses two essential components: radioisotope research, and radiopharmaceuticals manufacturing. Radiopharmaceuticals manufacturing program is not only quite unique, but also an essential component of King Faisal Specialist Hospital and Research Center (KFSH and RC) in providing quality patient care for the population of the Kingdom. Accurate diagnosis and therapy with medical imaging equipment requires quality radiopharmaceuticals that are available readily and with reliability. The CRP Department provides that quality and reliability. Research activities of the CRP Department are focused on developing new radiotracers with potential usefulness in biomedical research and clinical applications. Research projects consist of: developing cyclotron targetry for radioisotope production; developing synthesis methods for radiolabeling biomolecules; and developing analytical methods for quality control. The CRP Department operates a semi-commercial radiopharmaceuticals manufacturing program that supplies the diagnostic radioactive products to several hospitals in the Kingdom and neighboring countries. These products for clinical applications are produced according to the international standards of Good Manufacturing Practices of quality and efficacy. At the heart of the radioisotope program is a medium energy cyclotron capable of accelerating a number of particles for transformation of non-radioactive atoms into radionuclides that are the primary sources for research and development activities, and for preparing radiopharmaceuticals. In addition to having the only cyclotron facility in the region, KFSH and RC also has the only Positron Emission Tomography Center (PET) in this part of the world. This combination of cyclotron and the ultra modern PET facility translates into advanced and specialized care for the patients at KFSH and RC

  16. Commercial compact cyclotrons in the 90's

    International Nuclear Information System (INIS)

    Milton, B.F.

    1995-09-01

    Cyclotrons continue to be efficient accelerators for radio-isotope production. In recent years, developments in the accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicate a strong future for commercial cyclotrons. In this paper we will survey recent developments in the areas of cyclotron technology, as they relate to the new generation of commercial cyclotrons. Design criteria for the different types of commercial cyclotrons will be presented, with reference to those demands that differ from those in a research oriented cyclotron project. We will also discuss the possibility of systems designed for higher energies and capable of extracted beam currents of up to 2.0 mA. (author)

  17. Commercial compact cyclotrons in the 90's

    International Nuclear Information System (INIS)

    Milton, B.F.

    1995-09-01

    Cyclotrons continue to be efficient accelerators for radio-isotope production. In recent years, developments in the accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicate a strong future for commercial cyclotrons. In this paper the authors will survey recent developments in the areas of cyclotron technology, as they relate to the new generation of commercial cyclotrons. Design criteria for the different types of commercial cyclotrons will be presented, with reference to those demands that differ from those in a research oriented cyclotron project. The authors also discuss the possibility of systems designed for higher energies and capable of extracted beam currents of up to 2.0 mA

  18. Method and apparatus for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2010-08-17

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber that includes at least a first section that induces a first magnetron effect that increases a cyclotron frequency of an ion and at least a second section that induces a second magnetron effect that decreases the cyclotron frequency of an ion. The cyclotron frequency changes induced by the first and second magnetron effects substantially cancel one another so that an ion traversing the at least first and second sections will experience no net change in cyclotron frequency.

  19. 41 CFR 102-36.460 - Do we report excess medical shelf-life items held for national emergency purposes?

    Science.gov (United States)

    2010-07-01

    ... medical shelf-life items held for national emergency purposes? 102-36.460 Section 102-36.460 Public... Disposal Requires Special Handling Shelf-Life Items § 102-36.460 Do we report excess medical shelf-life items held for national emergency purposes? When the remaining shelf life of any medical materials or...

  20. Use of the National Board of Medical Examiners® Comprehensive Basic Science Exam: survey results of US medical schools.

    Science.gov (United States)

    Wright, William S; Baston, Kirk

    2017-01-01

    The National Board of Medical Examiners ® (NBME) Comprehensive Basic Science Exam (CBSE) is a subject exam offered to US medical schools, where it has been used for external validation of student preparedness for the United States Medical Licensing Examination ® (USMLE) Step 1 in new schools and schools undergoing curricular reform. Information regarding the actual use of the NBME CBSE is limited. Therefore, the aim of the survey was to determine the scope and utilization of the NBME CBSE by US medical schools. A survey was sent in May 2016 to curriculum leadership of the 139 US medical schools listed on the Liaison Committee on Medical Education (LCME ® ) website with provisional or full accreditation as of February 29, 2016. Responses were received from 53 schools (38% response rate). A series of different follow-up questions were asked if respondents stated "yes" or "no" to the initial question "Does your institution administer the NBME CBSE prior to the USMLE Step 1?". A total of 37 schools (70%) administered the NBME CBSE. In all, 36 of the 37 schools responded to follow-up questions. Of 36 schools, 13 schools (36%) used the NBME CBSE for curriculum modification. Six schools (17%) used the NBME CBSE for formative assessment for a course, and five schools (14%) used the NBME CBSE for summative assessment for a course. A total of 28 schools (78%) used the NBME CBSE for identifying students performing below expectations and providing targeted intervention strategies. In all, 24 schools (67%) of the 36 responding schools administering the NBME CBSE administered the test once prior to the administration of the USMLE Step 1, whereas 10 (28%) schools administered the NBME CBSE two or more times prior to the administration of the USMLE Step 1. Our data suggest that the NBME CBSE is administered by many US medical schools. However, the objective, timing, and number of exams administered vary greatly among schools.

  1. A new cyclotron for biomedical research

    International Nuclear Information System (INIS)

    Wolber, G.

    1988-01-01

    This paper presents the rationale for replacing the old AEG Compact Cyclotron (built in 1969/71) of the Institute for Radiology and Pathophysiology at the German Cancer Research Center by a 30 MeV H - /15 MeV D - cyclotron. A status report is followed by the scientific and technical reasoning as well as budgetary and organizational considerations. In the appendix we tried to explain the function of a cyclotron in a simple and comprehensive manner. (orig.) [de

  2. Radionuclide production and radiopharmaceutical chemistry with BNL cyclotrons

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Wolf, A.P.

    1985-01-01

    The Brookhaven National Laboratory (BNL) radiopharmaceutical chemistry program focuses on production and utilization of radionuclides having a half-life of > 2 hr. However, a major portion of the BNL program is devoted to short-lived radionuclides, such as 11 C and 18 F. Activities encompassed in the program are classified into seven areas: cyclotron parameters, radiochemistry, design and rapid synthesis of radiopharmaceuticals and labeled compounds, radiotracer evaluation in animals, studies in humans, technology transfer, and several other areas

  3. 78 FR 801 - National Emergency Medical Services Advisory Council (NEMSAC); Notice of Federal Advisory...

    Science.gov (United States)

    2013-01-04

    ...The NHTSA announces a meeting of NEMSAC to be held in the Metropolitan Washington, DC, area. This notice announces the date, time, and location of the meeting, which will be open to the public. The purpose of NEMSAC, a nationally recognized council of emergency medical services representatives and consumers, is to provide advice and recommendations regarding Emergency Medical Services (EMS) to DOT's NHTSA and to the Federal Interagency Committee on EMS (FICEMS).

  4. Evaluation of the production capabilities of 18F, 11C, 13N and 15O PET isotopes at the PET-cyclotron-radiochemistry site of Messina University

    OpenAIRE

    Auditore, Lucrezia; Amato, Ernesto; Italiano, Antonio; Pagano, Benedetta; Baldari, Sergio

    2017-01-01

    The production of 18F, 11C, 13N, and 15O positron emitting radionuclides for PET imaging is usually accomplished in Nuclear Medicine Departments through direct nuclear reactions induced by protons accelerated by compact medical cyclotrons on liquid or gaseous targets. Messina University has funded the construction of a PET-cyclotron-radio-chemistry plant at the Messina University Hospital, equipped with a 11 MeV self-shielded cyclotron. We estimated the expected production yields of these nuc...

  5. Surgical and procedural skills training at medical school - a national review.

    Science.gov (United States)

    Davis, Christopher R; Toll, Edward C; Bates, Anthony S; Cole, Matthew D; Smith, Frank C T

    2014-01-01

    This national study quantifies procedural and surgical skills training at medical schools in the United Kingdom (UK), a stipulated requirement of all graduates by the General Medical Council (GMC). A questionnaire recorded basic procedural and surgical skills training provided by medical schools and surgical societies in the UK. Skills were extracted from (1) GMC Tomorrows Doctors and (2) The Royal College of Surgeons Intercollegiate Basic Surgical Skills (BSS) course. Data from medical school curricula and extra-curricular student surgical societies were compared against the national GMC guidelines and BSS course content. Data were analysed using Mann-Whitney U tests. Representatives from 23 medical schools completed the survey (71.9% response). Thirty one skills extracted from the BSS course were split into 5 categories, with skills content cross referenced against GMC documentation. Training of surgical skills by medical schools was as follows: Gowning and gloving (72.8%), handling instruments (29.4%), knot tying (17.4%), suturing (24.7%), other surgical techniques (4.3%). Surgical societies provided significantly more training of knot tying (64.4%, P = 0.0013) and suturing (64.5%, P = 0.0325) than medical schools. Medical schools provide minimal basic surgical skills training, partially supplemented by extracurricular student surgical societies. Our findings suggest senior medical students do not possess simple surgical and procedural skills. Newly qualified doctors are at risk of being unable to safely perform practical procedures, contradicting GMC Guidelines. We propose a National Undergraduate Curriculum in Surgery and Surgical Skills to equip newly qualified doctors with basic procedural skills to maximise patient safety. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  6. National standards in pathology education: developing competencies for integrated medical school curricula.

    Science.gov (United States)

    Sadofsky, Moshe; Knollmann-Ritschel, Barbara; Conran, Richard M; Prystowsky, Michael B

    2014-03-01

    Medical school education has evolved from department-specific memorization of facts to an integrated curriculum presenting knowledge in a contextual manner across traditional disciplines, integrating information, improving retention, and facilitating application to clinical practice. Integration occurs throughout medical school using live data-sharing technologies, thereby providing the student with a framework for lifelong active learning. Incorporation of educational teams during medical school prepares students for team-based patient care, which is also required for pay-for-performance models used in accountable care organizations. To develop learning objectives for teaching pathology to medical students. Given the rapid expansion of basic science knowledge of human development, normal function, and pathobiology, it is neither possible nor desirable for faculty to teach, and students to retain, this vast amount of information. Courses teaching the essentials in context and engaging students in the learning process enable them to become lifelong learners. An appreciation of pathobiology and the role of laboratory medicine underlies the modern practice of medicine. As such, all medical students need to acquire 3 basic competencies in pathology: an understanding of disease mechanisms, integration of mechanisms into organ system pathology, and application of pathobiology to diagnostic medicine. We propose the development of 3 specific competencies in pathology to be implemented nationwide, aimed at disease mechanisms/processes, organ system pathology, and application to diagnostic medicine. Each competency will include learning objectives and a means to assess acquisition, integration, and application of knowledge. The learning objectives are designed to be a living document managed (curated) by a group of pathologists representing Liaison Committee on Medical Education-accredited medical schools nationally. Development of a coherent set of learning objectives will

  7. Building a national electronic medical record exchange system - experiences in Taiwan.

    Science.gov (United States)

    Li, Yu-Chuan Jack; Yen, Ju-Chuan; Chiu, Wen-Ta; Jian, Wen-Shan; Syed-Abdul, Shabbir; Hsu, Min-Huei

    2015-08-01

    There are currently 501 hospitals and about 20,000 clinics in Taiwan. The National Health Insurance (NHI) system, which is operated by the NHI Administration, uses a single-payer system and covers 99.9% of the nation's total population of 23,000,000. Taiwan's NHI provides people with a high degree of freedom in choosing their medical care options. However, there is the potential concern that the available medical resources will be overused. The number of doctor consultations per person per year is about 15. Duplication of laboratory tests and prescriptions are not rare either. Building an electronic medical record exchange system is a good method of solving these problems and of improving continuity in health care. In November 2009, Taiwan's Executive Yuan passed the 'Plan for accelerating the implementation of electronic medical record systems in medical institutions' (2010-2012; a 3-year plan). According to this plan, a patient can, at any hospital in Taiwan, by using his/her health insurance IC card and physician's medical professional IC card, upon signing a written agreement, retrieve all important medical records for the past 6 months from other participating hospitals. The focus of this plan is to establish the National Electronic Medical Record Exchange Centre (EEC). A hospital's information system will be connected to the EEC through an electronic medical record (EMR) gateway. The hospital will convert the medical records for the past 6 months in its EMR system into standardized files and save them on the EMR gateway. The most important functions of the EEC are to generate an index of all the XML files on the EMR gateways of all hospitals, and to provide search and retrieval services for hospitals and clinics. The EEC provides four standard inter-institution EMR retrieval services covering medical imaging reports, laboratory test reports, discharge summaries, and outpatient records. In this system, we adopted the Health Level 7 (HL7) Clinical Document

  8. Ranking Spain's medical schools by their performance in the national residency examination.

    Science.gov (United States)

    Lopez-Valcarcel, B G; Ortún, V; Barber, P; Harris, J E; García, B

    2013-12-01

    Medical school graduates in Spain must take a uniform national exam (called "examen MIR") in order to enter postgraduate training in a specialty. Its results offer a unique opportunity to rank medical schools according to this exam. We measured differences in the MIR exam results among Spanish medical schools and assessed the stability of the MIR-based rankings for the period 2003-2011. In the year 2011 a total of 6873 residency positions nationwide were offered by the Spanish Ministry of Health, Social Services and Equality. These positions covered 47 specialties distributed over 231 training centers. A total of 11,550 medical graduates (including 1997 foreign graduates) took the MIR examination. Marked differences among medical schools were evident. The median graduate from medical school #1 and #29 occupied the positions 1477 and 5383, respectively. These figures correspond to a standardized ranking of 21 out of 100 for medical school #1 (that is, 1477/6873; half of medical school #1 obtained better [below position 21%] and half worse [over position 21%] results) and a standardized ranking of 70 out of 100 for medical school #29. While 81% of the medical school #1 graduates were amongst the best 3000 MIR exams and only 5% above the 5000 position the corresponding figures for medical school #29 graduates were 21% and 44%, respectively. The ranking position of the 29 medical schools was very stable between the years 2003 and 2011. There are marked differences in medical schools in Spain and these differences are very consistent over the years 2003-2011. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  9. National awareness campaign to prevent medication-overuse headache in Denmark.

    Science.gov (United States)

    Carlsen, Louise Ninett; Westergaard, Maria Lurenda; Bisgaard, Mette; Schytz, Julie Brogaard; Jensen, Rigmor Højland

    2017-01-01

    Background Medication-overuse headache is prevalent, but in principle preventable. Objective To describe the Danish national awareness campaign for medication-overuse headache. Methods The Danish Headache Center, the Association of Danish Pharmacies, and headache patient organizations implemented a four-month medication-overuse headache awareness campaign in 2016. Target groups were the general public, general practitioners, and pharmacists. Key messages were: Overuse of pain-medication can worsen headaches; pain-medication should be used rationally; and medication-overuse headache is treatable. A range of communication technologies was used. A survey on the public's awareness of medication-overuse headache was conducted. Results The Danish adult population is 4.2 million. Online videos were viewed 297,000 times in three weeks. All 400 pharmacies received campaign materials. Over 28,000 leaflets were distributed. Two radio interviews were conducted. A television broadcast about headache reached an audience of 520,000. Forty articles were published in print media. Information was accessible at 32 reputable websites and five online news agencies. Three scientific papers were published. Information was available at an annual conference of general practitioners, including a headache lecture. The survey showed an increase in percentage of the public who knew about medication-overuse headache (from 31% to 38%). Conclusion A concerted campaign to prevent medication-overuse headache can be implemented through involvement of key stakeholders.

  10. Pediatric сlinic of Odessa National Medical University: the quality of emergency medical care for children

    Directory of Open Access Journals (Sweden)

    E.A. Starets

    2017-04-01

    Full Text Available Background. The purpose of the article is to discuss the issue of improving the quality of emergency care for children with the most common diseases. Materials and methods. The quality of medical care includes 6 characteristics: 1 effectiveness — evidencebased health care results in improved health outcomes; 2 relevancy: health care is delivered in a manner that maximizes resource use and avoids wasting and provided in a setting where skills and resources are appropriate to medical need; 3 accessibility: health care is provided timely, reasonable and affordable; 4 acceptability/patient-centered: health care provided takes into account the preferences and aspirations of individual service users; 5 equity: health care provided does not vary in quality because of personal characteristics or socioeconomic status; 6 safety: health care provided minimizes risks and harm to service users and providers. Results. The Intensive Care Unit (ICU started working in the Pediatric Clinic of the Odessa National Medical University on February 1, 2017. The main task of ICU is the treatment of children with emergency conditions (who needs monitoring of breathing and cardiac activity, oxygen therapy, large-volume rehydration therapy, etc. The patients admit to the ICU according the results of triage. Triage is the process of rapidly screening of sick children soon after their addmission to hospital and in ICU, in order to identify those with emergency signs — obstruc-ted breathing or severe respiratory distress; central cyanosis; signs of shock; signs of severe dehydration; those with priority signs — very high temperature, severe pallor, respiratory distress etc. The local guidelines for the most common diseases in children have been developed in the Pediatric Clinic. These local guidelines are based on: 1 modern national guidelines; 2 WHO: Pocket book of hospital care for children: guidelines for the management of common childhood illnesses (2013; clinical

  11. Task force St. Bernard: operational issues and medical management of a National Guard disaster response operation.

    Science.gov (United States)

    Bonnett, Carl J; Schock, Tony R; McVaney, Kevin E; Colwell, Christopher B; Depass, Christopher

    2007-01-01

    After Hurricane Katrina struck the Gulf Coast of the United States on 29 August 2005, it became obvious that the country was facing an enormous national emergency. With local resources overwhelmed, governors across the US responded by deploying thousands of National Guard soldiers and airmen. The National Guard has responded to domestic disasters due to natural hazards since its inception, but an event with the magnitude of Hurricane Katrina was unprecedented. The deployment of >900 Army National Guard soldiers to St. Bernard Parish, Louisiana in the aftermath of the Hurricane was studied to present some of the operational issues involved with providing medical support for this type of operation. In doing so, the authors attempt to address some of the larger issues of how the National Guard can be incorporated into domestic disaster response efforts. A number of unforeseen issues with regards to medical operations, medical supply, communication, preventive medicine, legal issues, and interactions with civilians were encountered and are reviewed. A better understanding of the National Guard and how it can be utilized more effectively in future disaster response operations can be developed.

  12. The cyclotron laboratory and the RFQ accelerator in Bern

    International Nuclear Information System (INIS)

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Weber, M.; Scampoli, P.; Bremen, K. von

    2013-01-01

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study

  13. The cyclotron laboratory and the RFQ accelerator in Bern

    Energy Technology Data Exchange (ETDEWEB)

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Weber, M. [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern (Switzerland); Scampoli, P. [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern, Switzerland and Department of Physical Sciences, University Federico II, Via Cintia, I-60126 Napoli (Italy); Bremen, K. von [SWAN Isotopen AG, Inselspital, CH-3010 Bern (Switzerland)

    2013-07-18

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

  14. [Medical rescue of China National Earthquake Disaster Emergency Search and Rescue Team in Lushan earthquake].

    Science.gov (United States)

    Liu, Ya-hua; Yang, Hui-ning; Liu, Hui-liang; Wang, Fan; Hu, Li-bin; Zheng, Jing-chen

    2013-05-01

    To summarize and analyze the medical mission of China National Earthquake Disaster Emergency Search and Rescue Team (CNESAR) in Lushan earthquake, to promote the medical rescue effectiveness incorporated with search and rescue. Retrospective analysis of medical work data by CNESAR from April 21th, 2013 to April 27th during Lushan earthquake rescue, including the medical staff dispatch and the wounded case been treated. The reasonable medical corps was composed by 22 members, including 2 administrators, 11 doctors [covering emergency medicine, orthopedics (joints and limbs, spinal), obstetrics and gynecology, gastroenterology, cardiology, ophthalmology, anesthesiology, medical rescue, health epidemic prevention, clinical laboratory of 11 specialties], 1 ultrasound technician, 5 nurses, 1 pharmacist, 1 medical instrument engineer and 1 office worker for propaganda. There were two members having psychological consultants qualifications. The medical work were carried out in seven aspects, including medical care assurance for the CNESAR members, first aid cooperation with search and rescue on site, clinical work in refugees' camp, medical round service for scattered village people, evacuation for the wounded, mental intervention, and the sanitary and anti-epidemic work. The medical work covered 24 small towns, and medical staff established 3 medical clinics at Taiping Town, Shuangshi Town of Lushan County and Baoxing County. Medical rescue, mental intervention for the old and kids, and sanitary and anti-epidemic were performed at the above sites. The medical corps had successful evacuated 2 severe wounded patients and treated the wounded over thousands. Most of the wounded were soft tissue injuries, external injury, respiratory tract infections, diarrhea, and heat stroke. Compared with the rescue action in 2008 Wenchuan earthquake, the aggregation and departure of rescue team in Lushan earthquake, the traffic control order in disaster area, the self-aid and buddy aid

  15. Research and development of ion surfing RF carpets for the cyclotron gas stopper at the NSCL

    Energy Technology Data Exchange (ETDEWEB)

    Gehring, A.E. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87544 (United States); Brodeur, M. [University of Notre Dame, Notre Dame, IN (United States); Bollen, G.; Morrissey, D.J.; Schwarz, S. [National Superconducting Cyclotron Laboratory, Michigan State University, 640 S. Shaw Lane, East Lansing, MI 48824 (United States)

    2016-06-01

    A model device to transport thermal ions in the cyclotron gas stopper, a next-generation beam thermalization device under construction at the National Superconducting Cyclotron Laboratory, is presented. Radioactive ions produced by projectile fragmentation will come to rest at distances as large as 45 cm from the extraction orifice of the cyclotron gas stopper. The thermalized ions will be transported to the exit by RF carpets employing the recently developed “ion surfing” method. A quarter-circle prototype RF carpet was tested with potassium ions, and ion transport velocities as high as 60 m/s were observed over distances greater than 10 cm at a helium buffer gas pressure of 80 mbar. The transport of rubidium ions from an RF carpet to an electrode below was also demonstrated. The results of this study formed the basis of the design of the RF carpets for use in the cyclotron gas stopper.

  16. National priorities for the assessment of clinical conditions and medical technologies: report of a pilot study

    National Research Council Canada - National Science Library

    Lara, María Elena; Goodman, Clifford

    1990-01-01

    ... and Medical Technologies Report of a Pilot Study Maria Elena Lara and Clifford Goodman, editors Priority-Setting Group Council on Health Care Technology Institute of Medicine NATIONAL ACADEMY PRESS WASHINGTON, D.C. 1990 i Copyrightoriginal retained, the be not from cannot book, paper original however, for version formatting, authoritative the typese...

  17. Summary on electron cyclotron theory

    International Nuclear Information System (INIS)

    Westerhof, E.

    2003-01-01

    The papers presented within the Theory Sessions of the conference clearly reflect the general trends of the research field. The growing use of Electron Bernstein Waves (EBW) for plasma heating and current drive in overdense plasmas goes hand in hand with an increased theoretical understanding of EBW excitation. While the expanding number of devices with powerful ECRH systems allowing ever more detailed experiments is reflected in the increased detail of modelling and consequent understanding of the experimental results. Apart from these general trends, some more fundamental contributions to the field of electron cyclotron wave propagation are highlighted. (author)

  18. Comparison of Iranian National Medical Library with digital libraries of selected countries.

    Science.gov (United States)

    Zare-Farashbandi, Firoozeh; Najafi, Nayere Sadat Soleimanzade; Atashpour, Bahare

    2014-01-01

    The important role of information and communication technologies and their influence on methods of storing, retrieving information in digital libraries, has not only changed the meanings behind classic library activates but has also created great changes in their services. However, it seems that not all digital libraries provide their users with similar services and only some of them are successful in fulfilling their role in digital environment. The Iranian National Medical library is among those that appear to come short compared to other digital libraries around the world. By knowing the different services provided by digital libraries worldwide, one can evaluate the services provided by Iranian National Medical library. The goal of this study is a comparison between Iranian National Medical library and digital libraries of selected countries. This is an applied study and uses descriptive - survey method. The statistical population is the digital libraries around the world which were actively providing library services between October and December 2011 and were selected by using the key word "Digital Library" in Google search engine. The data-gathering tool was direct access to the websites of these digital libraries. The statistical study is descriptive and Excel software was used for data analysis and plotting of the charts. The findings showed that among the 33 digital libraries investigated worldwide, most of them provided Browse (87.87%), Search (84.84%), and Electronic information retrieval (57.57%) services. The "Help" in public services (48/48%) and "Interlibrary Loan" in traditional services (27/27%) had the highest frequency. The Iranian National Medical library provides more digital services compared to other libraries but has less classic and public services and has less than half of possible public services. Other than Iranian National Medical library, among the 33 libraries investigated, the leaders in providing different services are Library of

  19. The Institutional Foundations of Medicalization: A Cross-national Analysis of Mental Health and Unemployment.

    Science.gov (United States)

    Buffel, Veerle; Beckfield, Jason; Bracke, Piet

    2017-09-01

    In this study, we question (1) whether the relationship between unemployment and mental healthcare use, controlling for mental health status, varies across European countries and (2) whether these differences are patterned by a combination of unemployment and healthcare generosity. We hypothesize that medicalization of unemployment is stronger in countries where a low level of unemployment generosity is combined with a high level of healthcare generosity. A subsample of 36,306 working-age respondents from rounds 64.4 (2005-2006) and 73.2 (2010) of the cross-national survey Eurobarometer was used. Country-specific logistic regression and multilevel analyses, controlling for public disability spending, changes in government spending, economic capacity, and unemployment rate, were performed. We find that unemployment is medicalized, at least to some degree, in the majority of the 24 nations surveyed. Moreover, the medicalization of unemployment varies substantially across countries, corresponding to the combination of the level of unemployment and of healthcare generosity.

  20. Studies of electron cyclotron emission on text

    International Nuclear Information System (INIS)

    Gandy, R.F.

    1990-07-01

    The Auburn University electron cyclotron emission (ECE) system has made many significant contributions to the TEXT experimental program during the past five years. Contributions include electron temperature information used in the following areas of study: electron cyclotron heating (ECH), pellet injection, and impurity/energy transport. Details of the role which the Auburn ECE system has played will now be discussed

  1. Cyclotrons for the production of radioactive beams

    International Nuclear Information System (INIS)

    Clark, D.J.

    1990-01-01

    This paper describes the characteristics and design choices for modern cyclotrons. Cyclotrons can be used in 3 areas in the radioactive beam field: the production of high energy heavy ion beams for use in fragmentation, the spallation of targets with high energy protons, and the acceleration of radioactive beams from low energy to the MeV/u range. 16 refs., 6 figs

  2. Isochronous cyclotron for thermonuclear reactors driving

    International Nuclear Information System (INIS)

    Alenitskij, Yu.G.

    1998-01-01

    The main requirements to an accelerator as a part of an electronuclear power plant are considered. The range of the parameters of the accelerated proton and deuteron beams, for which the isochronous cyclotron is the most profitable, is proposed. An opportunity of using the cyclotron to drive the research reactors of various types is considered

  3. Wave fronts of electromagnetic cyclotron harmonic waves

    International Nuclear Information System (INIS)

    Ohnuma, T.; Watanabe, T.

    1982-01-01

    In an inhomogeneous high-density magnetized plasma, the spatial properties of the wave fronts and ray trajectories of electromagnetic ordinary and extraordinary cyclotron harmonic waves are investigated. Those waves which are radiated from a local source are found to have wave fronts which are almost parallel to the magnetic field. Also, the reflective properties of the electromagnetic cyclotron harmonic waves are confirmed

  4. Computer design of a compact cyclotron

    International Nuclear Information System (INIS)

    Bing Wang; Huanfeng Hao; Qinggao Yao; Jinquan Zhang; Mingtao Song; Vorozhtsov, S.B.; Smirnov, V.L.; Hongwei Zhao

    2011-01-01

    Here we present results of the computer design of the structural elements of a compact cyclotron by the example of HITFiL cyclotron selected as the driving accelerator that is under construction at the Institute of Modern Physics (Lanzhou, China). In the article a complex approach to modeling of the compact cyclotron, including calculation of electromagnetic fields of the structural elements and beam dynamics calculations, is described. The existing design data on the axial injection, magnetic, acceleration and extraction systems of the cyclotron are used as a starting point in the simulation. Some of the upgrades of the cyclotron structural elements were proposed, which led to substantial improvement of the beam quality and transmission

  5. Use of the National Board of Medical Examiners® Comprehensive Basic Science Exam: survey results of US medical schools

    Directory of Open Access Journals (Sweden)

    Wright WS

    2017-06-01

    Full Text Available William S Wright,1 Kirk Baston2 1Department of Biomedical Sciences, 2Department of Pathology, University of South Carolina School of Medicine Greenville, Greenville, SC, USA Purpose: The National Board of Medical Examiners® (NBME Comprehensive Basic Science Exam (CBSE is a subject exam offered to US medical schools, where it has been used for external validation of student preparedness for the United States Medical Licensing Examination® (USMLE Step 1 in new schools and schools undergoing curricular reform. Information regarding the actual use of the NBME CBSE is limited. Therefore, the aim of the survey was to determine the scope and utilization of the NBME CBSE by US medical schools.Methods: A survey was sent in May 2016 to curriculum leadership of the 139 US medical schools listed on the Liaison Committee on Medical Education (LCME® website with provisional or full accreditation as of February 29, 2016. Responses were received from 53 schools (38% response rate. A series of different follow-up questions were asked if respondents stated “yes” or “no” to the initial question “Does your institution administer the NBME CBSE prior to the USMLE Step 1?”.Results: A total of 37 schools (70% administered the NBME CBSE. In all, 36 of the 37 schools responded to follow-up questions. Of 36 schools, 13 schools (36% used the NBME CBSE for curriculum modification. Six schools (17% used the NBME CBSE for formative assessment for a course, and five schools (14% used the NBME CBSE for summative assessment for a course. A total of 28 schools (78% used the NBME CBSE for identifying students performing below expectations and providing targeted intervention strategies. In all, 24 schools (67% of the 36 responding schools administering the NBME CBSE administered the test once prior to the administration of the USMLE Step 1, whereas 10 (28% schools administered the NBME CBSE two or more times prior to the administration of the USMLE Step 1.Conclusion

  6. The national institute of radiation hygiene and the medical application of radiation

    International Nuclear Information System (INIS)

    Baarli, J.

    1988-01-01

    This paper gives a review of the rules and regulations concerning medical application of radiation in Norway. It discusses the intention of the regulations, the way in which the regulations is applied and how the National Institute of Radiation Hygiene as the competent authority assures the application of the regulations. The paper furthermore gives an indication of the areas of radiation application in medicine and the number of location of X-ray equipment, nuclear medical laboratories, radiation therapy equipment, etc. The number of X-ray examinations in Norway per year are also given, together with their distribution among the various types of examinations. Summary results of a quality assurance investigation of nuclear medical laboratories are given, as well as the results of inspections of the various types of equipment used in medical diagnostics

  7. Cyclotron-Resonance-Maser Arrays

    International Nuclear Information System (INIS)

    Kesar, A.; Lei, L.; Dikhtyar, V.; Korol, M.; Jerby, E.

    1999-01-01

    The cyclotron-resonance-maser (CRM) array [1] is a radiation source which consists of CRM elements coupled together under a common magnetic field. Each CRM-element employs a low-energy electron-beam which performs a cyclotron interaction with the local electromagnetic wave. These waves can be coupled together among the CRM elements, hence the interaction is coherently synchronized in the entire array. The implementation of the CRM-array approach may alleviate several technological difficulties which impede the development of single-beam gyro-devices. Furthermore, it proposes new features, such as the phased-array antenna incorporated in the CRM-array itself. The CRM-array studies may lead to the development of compact, high-power radiation sources operating at low-voltages. This paper introduces new conceptual schemes of CRM-arrays, and presents the progress in related theoretical and experimental studies in our laboratory. These include a multi-mode analysis of a CRM-array, and a first operation of this device with five carbon-fiber cathodes

  8. The Medical Home Model and Pediatric Asthma Symptom Severity: Evidence from a National Health Survey.

    Science.gov (United States)

    Rojanasarot, Sirikan; Carlson, Angeline M

    2018-04-01

    The objective was to investigate the association between receiving care under the medical home model and parental assessment of the severity of asthma symptoms. It was hypothesized that parents of children who received care under the medical home model reported less severe asthma symptoms compared with their counterparts, whose care did not meet the medical home criteria. Secondary analyses were conducted using cross-sectional data from the 2011-2012 National Survey of Children's Health. Children with asthma aged 0-17 years were included and classified as receiving care from the medical home if their care contained 5 components: a personal doctor, a usual source of sick care, family-centered care, no problems getting referrals, and effective care coordination. Ordinal logistic regression was used to examine the relationship between parent-rated severity of asthma symptoms (mild, moderate, and severe symptoms) and the medical home. Approximately 52% of 8229 children who reported having asthma received care from the medical home. Only 30.8% of children with severe asthma symptoms received care that met the medical home criteria, compared to 55.7% of children with mild symptoms. After accounting for confounding factors, obtaining care under the medical home model decreased the odds of parent-reported severe asthma symptoms by 31% (adjusted odds ratio 0.69; 95% CI, 0.56-0.85). Study results suggest that the medical home model can reduce parent-rated severity of asthma symptoms. The findings highlight the importance of providing medical home care to children with asthma to improve the outcomes that matter most to children and their families.

  9. The State of Leadership Education in Emergency Medical Services: A Multi-national Qualitative Study.

    Science.gov (United States)

    Leggio, William Joseph

    2014-10-01

    This study investigated how leadership is learned in Emergency Medical Services (EMS) from a multi-national perspective by interviewing EMS providers from multiple nations working in Riyadh, Kingdom of Saudi Arabia. A phenomenological, qualitative methodology was developed and 19 EMS providers from multiple nations were interviewed in June 2013. Interview questions focused on how participants learned EMS leadership as an EMS student and throughout their careers as providers. Data were analyzed to identify themes, patterns, and codes to be used for final analysis to describe findings. Emergency Medical Services leadership is primarily learned from informal mentoring and on-the-job training in less than supportive environments. Participants described learning EMS leadership during their EMS education. A triangulation of EMS educational resources yielded limited results beyond being a leader of patient care. The only course that yielded results from triangulation was EMS Management. The need to develop EMS leadership courses was supported by the findings. Findings also supported the need to include leadership education as part of continuing medical education and training. Emergency Medical Services leadership education that prepares students for the complexities of the profession is needed. Likewise, the need for EMS leadership education and training to be part of continuing education is supported. Both are viewed as a way to advance the EMS profession. A need for further research on the topic of EMS leadership is recognized, and supported, with a call for action on suggested topics identified within the study.

  10. Emergency medical consequence planning and management for national special security events after September 11: Boston 2004.

    Science.gov (United States)

    Kade, Kristy A; Brinsfield, Kathryn H; Serino, Richard A; Savoia, Elena; Koh, Howard K

    2008-10-01

    The post-September 11 era has prompted unprecedented attention to medical preparations for national special security events (NSSE), requiring extraordinary planning and coordination among federal, state, and local agencies. For an NSSE, the US Secret Service (USSS) serves as the lead agency for all security operations and coordinates with relevant partners to provide for the safety and welfare of participants. For the 2004 Democratic National Convention (DNC), designated an NSSE, the USSS tasked the Boston Emergency Medical Services (BEMS) of the Boston Public Health Commission with the design and implementation of health services related to the Convention. In this article, we describe the planning and development of BEMS' robust 2004 DNC Medical Consequence Management Plan, addressing the following activities: public health surveillance, on-site medical care, surge capacity in the event of a mass casualty incident, and management of federal response assets. Lessons learned from enhanced medical planning for the 2004 DNC may serve as an effective model for future mass gathering events.

  11. Receipt of Post-Rape Medical Care in a National Sample of Female Victims

    Science.gov (United States)

    Zinzow, Heidi M.; Resnick, Heidi S.; Barr, Simone C.; Danielson, Carla K.; Kilpatrick, Dean G.

    2014-01-01

    Background It is important for rape victims to receive medical care to prevent and treat rape-related diseases and injuries, access forensic exams, and connect to needed resources. Few victims seek care, and factors associated with post-rape medical care–seeking are poorly understood. Purpose The current study examined prevalence and factors associated with post-rape medical care–seeking in a national sample of women who reported a most-recent or only incident of forcible rape, and drug- or alcohol-facilitated/incapacitated rape when they were aged ≥14 years. Methods A national sample of U.S. adult women (N=3001) completed structured telephone interviews in 2006, and data for this study were analyzed in 2011. Logistic regression analyses examined demographic variables, health, rape characteristics, and post-rape concerns in relation to post-rape medical care–seeking among 445 female rape victims. Results A minority of rape victims (21%) sought post-rape medical attention following the incident. In the final multivariate model, correlates of medical care included black race, rape-related injury, concerns about sexually transmitted diseases, pregnancy concerns, and reporting the incident to police. Conclusions Women who experience rapes consistent with stereotypic scenarios, acknowledge the rape, report the rape, and harbor health concerns appear to be more likely to seek post-rape medical services. Education is needed to increase rape acknowledgment, awareness of post-rape services that do not require formal reporting, and recognition of the need to treat rape-related health problems. PMID:22813683

  12. Influence of national culture on the adoption of integrated medical curricula.

    Science.gov (United States)

    Jippes, Mariëlle; Majoor, Gerard D

    2011-03-01

    Integrated curricula have been implemented in medical schools all over the world. However, among countries different relative numbers of schools with integrated curricula are found. This study aims to explore the possible correlation between the percentage of medical schools with integrated curricula in a country and that country's cultural characteristics. Curricula were defined as not integrated if in the first 2 years of the program at least two out of the three monodisciplinary courses Anatomy, Physiology and Biochemistry were identified. Culture was defined using Hofstede's dimensions Power distance, Uncertainty avoidance, Masculinity/Femininity, and Individualism/Collectivism. Consequently, this study had to be restricted to the 63 countries included in Hofstede's studies which harbored 1,195 medical schools. From each country we randomly sampled a maximum of 15 schools yielding 484 schools to be investigated. In total 91% (446) of the curricula were found. Correlation of percent integrated curricula and each dimension of culture was determined by calculating Spearman's Rho. A high score on the Power distance index and a high score on the Uncertainty avoidance index correlated with a low percent integrated curricula; a high score on the Individualism index correlated with a high percent integrated curricula. The percentage integrated curricula in a country did not correlate with its score on the Masculinity index. National culture is associated with the propensity of medical schools to adopt integrated medical curricula. Consequently, medical schools considering introduction of integrated and problem-based medical curricula should take into account dimensions of national culture which may hinder the innovation process.

  13. National health and medical services response to incidents of chemical and biological terrorism.

    Science.gov (United States)

    Tucker, J B

    1997-08-06

    In response to the growing threat of terrorism with chemical and biological weapons, the US government has developed a national concept of operations for emergency health and medical services response. This capability was developed and tested for the first time during the Atlanta Olympic Games in the summer of 1996. In the event of a chemical or biological terrorist incident that exceeded local and state-level response capabilities, federal agencies would provide specialized teams and equipment to help manage the consequences of the attack and treat, decontaminate, and evacuate casualties. The US Congress has also established a Domestic Preparedness Program that provides for enhanced training of local first-responders and the formation of metropolitan medical strike teams in major cities around the country. While these national response capabilities are promising, their implementation to date has been problematic and their ultimate effectiveness is uncertain.

  14. NIRS report concerning the cyclotron usages. FY 2000

    International Nuclear Information System (INIS)

    2001-07-01

    This report describes the National Institute of Radiological Sciences (NIRS) cyclotron usages concerning of: Operation and improvement-development of the cyclotrons in 2000 (total 1,302 hr operation, development of the insulating septum, renewal of the magnetic channel and radiofrequency (RF) pre-amplifier, and improvement of the magnetic interference); Development of neutron detectors in the cosmic environment (the phoswich detector, low-pressure proportional counter, bubble dosimeter and new type phoswich detector); Development of detectors of charged particle components in the cosmic radiation (Liulin-4J and position sensitive silicon detector); Measurement of the energy and angular distribution of secondary electrons from water vapor with heavy-ion impact; Phase II clinical trials of proton beam therapy for ophthalmological tumors (34 patients in 1996-2000 and survival rate 100% within 3 years); Application of cyclotrons for RI production (mainly, 11 C, 13 N, 15 O and 18 F for basic and clinical PET); Studies on the spread-out peak of proton beam (for radiotherapy); and Related materials to above (details). (N.I.)

  15. Electron cyclotron resonance plasma photos

    Energy Technology Data Exchange (ETDEWEB)

    Racz, R.; Palinkas, J. [Institute of Nuclear Research (ATOMKI), H-4026 Debrecen, Bem ter 18/c (Hungary); University of Debrecen, H-4010 Debrecen, Egyetem ter 1 (Hungary); Biri, S. [Institute of Nuclear Research (ATOMKI), H-4026 Debrecen, Bem ter 18/c (Hungary)

    2010-02-15

    In order to observe and study systematically the plasma of electron cyclotron resonance (ECR) ion sources (ECRIS) we made a high number of high-resolution visible light plasma photos and movies in the ATOMKI ECRIS Laboratory. This required building the ECR ion source into an open ECR plasma device, temporarily. An 8MP digital camera was used to record photos of plasmas made from Ne, Ar, and Kr gases and from their mixtures. We studied and recorded the effect of ion source setting parameters (gas pressure, gas composition, magnetic field, and microwave power) to the shape, color, and structure of the plasma. The analysis of the photo series gave us many qualitative and numerous valuable physical information on the nature of ECR plasmas.

  16. Electron cyclotron resonance plasma photos

    International Nuclear Information System (INIS)

    Racz, R.; Palinkas, J.; Biri, S.

    2010-01-01

    In order to observe and study systematically the plasma of electron cyclotron resonance (ECR) ion sources (ECRIS) we made a high number of high-resolution visible light plasma photos and movies in the ATOMKI ECRIS Laboratory. This required building the ECR ion source into an open ECR plasma device, temporarily. An 8MP digital camera was used to record photos of plasmas made from Ne, Ar, and Kr gases and from their mixtures. We studied and recorded the effect of ion source setting parameters (gas pressure, gas composition, magnetic field, and microwave power) to the shape, color, and structure of the plasma. The analysis of the photo series gave us many qualitative and numerous valuable physical information on the nature of ECR plasmas.

  17. Channeling experiments at IPNE Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, F; Dumitru, M; Ivan, A [Cyclotron Laboratory, Institute of Atomic Physics, Institute of Physics and Nuclear Engineering, R-76900 Bucharest, P.O.Box MG-6, (Romania)

    1992-01-01

    Channeling experiments have been performed at the I.P.N.E Cyclotron using a 3 MeV alpha beam. A slide system cut the beam up to 5 minutes spatial resolution with a maximum 60 nA beam current on the target. The two-axis goniometer, fully computer-controlled, moves the target, a silicon wafer, with 2.5 minute resolution, while an alpha particle sensitive solid state detector, monitors the backscattered particle fluence. In the first stage, channeling appears to be a simple, fast and reliable method for precise monocrystal orientation. A reduction of the host yield by a factor of two allowed impurities and defects to be studied. (Author).

  18. Cyclotron resonance in bilayer graphene.

    Science.gov (United States)

    Henriksen, E A; Jiang, Z; Tung, L-C; Schwartz, M E; Takita, M; Wang, Y-J; Kim, P; Stormer, H L

    2008-02-29

    We present the first measurements of cyclotron resonance of electrons and holes in bilayer graphene. In magnetic fields up to B=18 T, we observe four distinct intraband transitions in both the conduction and valence bands. The transition energies are roughly linear in B between the lowest Landau levels, whereas they follow square root[B] for the higher transitions. This highly unusual behavior represents a change from a parabolic to a linear energy dispersion. The density of states derived from our data generally agrees with the existing lowest order tight binding calculation for bilayer graphene. However, in comparing data to theory, a single set of fitting parameters fails to describe the experimental results.

  19. Influence of Continuing Medical Education on Rheumatologists' Performance on National Quality Measures for Rheumatoid Arthritis.

    Science.gov (United States)

    Sapir, Tamar; Rusie, Erica; Greene, Laurence; Yazdany, Jinoos; Robbins, Mark L; Ruderman, Eric M; Carter, Jeffrey D; Patel, Barry; Moreo, Kathleen

    2015-12-01

    In recent years researchers have reported deficits in the quality of care provided to patients with rheumatoid arthritis (RA), including low rates of performance on quality measures. We sought to determine the influence of a quality improvement (QI) continuing education program on rheumatologists' performance on national quality measures for RA, along with other measures aligned with National Quality Strategy priorities. Performance was assessed through baseline and post-education chart audits. Twenty community-based rheumatologists across the United States were recruited to participate in the QI education program and chart audits. Charts were retrospectively audited before (n = 160 charts) and after (n = 160 charts) the rheumatologists participated in a series of accredited QI-focused educational activities that included private audit feedback, small-group webinars, and online- and mobile-accessible print and video activities. The charts were audited for patient demographics and the rheumatologists' documented performance on the 6 quality measures for RA included in the Physician Quality Reporting System (PQRS). In addition, charts were abstracted for documentation of patient counseling about medication benefits/risks and adherence, lifestyle modifications, and quality of life; assessment of RA medication side effects; and assessment of RA medication adherence. Mean rates of documented performance on 4 of the 6 PQRS measures for RA were significantly higher in the post-education versus baseline charts (absolute increases ranged from 9 to 24% of patient charts). In addition, after the intervention, significantly higher mean rates were observed for patient counseling about medications and quality of life, and for assessments of medication side effects and adherence (absolute increases ranged from 9 to 40% of patient charts). This pragmatic study provides preliminary evidence for the positive influence of QI-focused education in helping rheumatologists improve

  20. Management evaluation about introduction of electric medical record in the national hospital organization.

    Science.gov (United States)

    Nakagawa, Yoshiaki; Tomita, Naoko; Irisa, Kaoru; Yoshihara, Hiroyuki; Nakagawa, Yoshinobu

    2013-01-01

    Introduction of Electronic Medical Record (EMR) into a hospital was started from 1999 in Japan. Then, most of all EMR company said that EMR improved efficacy of the management of the hospital. National Hospital Organization (NHO) has been promoting the project and introduced EMR since 2004. NHO has 143 hospitals, 51 hospitals offer acute-phase medical care services, the other 92 hospitals offer medical services mainly for chronic patients. We conducted three kinds of investigations, questionnaire survey, checking the homepage information of the hospitals and analyzing the financial statements of each NHO hospital. In this financial analysis, we applied new indicators which have been developed based on personnel costs. In 2011, there are 44 hospitals which have introduced EMR. In our result, the hospital with EMR performed more investment of equipment/capital than personnel expenses. So, there is no advantage of EMR on the financial efficacy.

  1. Characteristics of pediatric chemotherapy medication errors in a national error reporting database.

    Science.gov (United States)

    Rinke, Michael L; Shore, Andrew D; Morlock, Laura; Hicks, Rodney W; Miller, Marlene R

    2007-07-01

    Little is known regarding chemotherapy medication errors in pediatrics despite studies suggesting high rates of overall pediatric medication errors. In this study, the authors examined patterns in pediatric chemotherapy errors. The authors queried the United States Pharmacopeia MEDMARX database, a national, voluntary, Internet-accessible error reporting system, for all error reports from 1999 through 2004 that involved chemotherapy medications and patients aged error reports, 85% reached the patient, and 15.6% required additional patient monitoring or therapeutic intervention. Forty-eight percent of errors originated in the administering phase of medication delivery, and 30% originated in the drug-dispensing phase. Of the 387 medications cited, 39.5% were antimetabolites, 14.0% were alkylating agents, 9.3% were anthracyclines, and 9.3% were topoisomerase inhibitors. The most commonly involved chemotherapeutic agents were methotrexate (15.3%), cytarabine (12.1%), and etoposide (8.3%). The most common error types were improper dose/quantity (22.9% of 327 cited error types), wrong time (22.6%), omission error (14.1%), and wrong administration technique/wrong route (12.2%). The most common error causes were performance deficit (41.3% of 547 cited error causes), equipment and medication delivery devices (12.4%), communication (8.8%), knowledge deficit (6.8%), and written order errors (5.5%). Four of the 5 most serious errors occurred at community hospitals. Pediatric chemotherapy errors often reached the patient, potentially were harmful, and differed in quality between outpatient and inpatient areas. This study indicated which chemotherapeutic agents most often were involved in errors and that administering errors were common. Investigation is needed regarding targeted medication administration safeguards for these high-risk medications. Copyright (c) 2007 American Cancer Society.

  2. Medication errors reported to the National Medication Error Reporting System in Malaysia: a 4-year retrospective review (2009 to 2012).

    Science.gov (United States)

    Samsiah, A; Othman, Noordin; Jamshed, Shazia; Hassali, Mohamed Azmi; Wan-Mohaina, W M

    2016-12-01

    Reporting and analysing the data on medication errors (MEs) is important and contributes to a better understanding of the error-prone environment. This study aims to examine the characteristics of errors submitted to the National Medication Error Reporting System (MERS) in Malaysia. A retrospective review of reports received from 1 January 2009 to 31 December 2012 was undertaken. Descriptive statistics method was applied. A total of 17,357 MEs reported were reviewed. The majority of errors were from public-funded hospitals. Near misses were classified in 86.3 % of the errors. The majority of errors (98.1 %) had no harmful effects on the patients. Prescribing contributed to more than three-quarters of the overall errors (76.1 %). Pharmacists detected and reported the majority of errors (92.1 %). Cases of erroneous dosage or strength of medicine (30.75 %) were the leading type of error, whilst cardiovascular (25.4 %) was the most common category of drug found. MERS provides rich information on the characteristics of reported MEs. Low contribution to reporting from healthcare facilities other than government hospitals and non-pharmacists requires further investigation. Thus, a feasible approach to promote MERS among healthcare providers in both public and private sectors needs to be formulated and strengthened. Preventive measures to minimise MEs should be directed to improve prescribing competency among the fallible prescribers identified.

  3. [Problems in career planning for novice medical technologists in Japanese national hospitals].

    Science.gov (United States)

    Ogasawara, Shu; Tsutaya, Shoji; Akimoto, Hiroyuki; Kojima, Keiya; Yabaka, Hiroyuki

    2012-12-01

    Skills and knowledge regarding many different types of test are required for medical technologists (MTs) to provide accurate information to help doctors and other medical specialists. In order to become an efficient MT, specialized training programs are required. Certification in specialized areas of clinical laboratory sciences or a doctoral degree in medical sciences may help MTs to realize career advancement, a higher earning potential, and expand the options in their career. However, most young MTs in national university hospitals are employed as part-time workers on a three-year contract, which is too short to obtain certifications or a doctoral degree. We have to leave the hospital without expanding our future. We need to take control of our own development in order to enhance our employability within the period. As teaching and training hospitals, national university hospitals in Japan are facing a difficult dilemma in nurturing MTs. I hope, as a novice medical technologist, that at least university hospitals in Japan create an appropriate workplace environment for novice MTs.

  4. National variation of ADHD diagnostic prevalence and medication use: health care providers and education policies.

    Science.gov (United States)

    Fulton, Brent D; Scheffler, Richard M; Hinshaw, Stephen P; Levine, Peter; Stone, Susan; Brown, Timothy T; Modrek, Sepideh

    2009-08-01

    Attention-deficit hyperactivity disorder (ADHD) diagnostic prevalence and medication use vary across U.S. census regions, but little is known about state-level variation. The purpose of this study was to estimate this variation across states and examine whether a state's health care provider characteristics and education policies are associated with this variation. Logistic regression models were estimated with 69,505 children aged four to 17 from the state-stratified and nationally representative 2003 National Survey of Children's Health, conducted by the Centers for Disease Control and Prevention. Diagnostic prevalence was higher in the South (odds ratio [OR]=1.42, p<.001) than in the West; among children with ADHD diagnoses, medication use was higher in the South (OR=1.60, p<.01) and the Midwest (OR=1.53, p<.01) versus the West. On these measures, several states differed from the U.S. averages, including some states that, on the basis of the regional patterns found above, would not be expected to differ: Michigan had a high diagnostic prevalence; Vermont, South Dakota, and Nebraska had low diagnostic prevalences; and Connecticut, New Jersey, and Kentucky had low medication rates. Both diagnosis and medication status were associated with the number, age, and type of physicians within a state, particularly pediatricians. However, state education policies were not significantly associated with either diagnostic prevalence or medication rates. To better understand the association between a state's health care provider characteristics and both diagnostic prevalence and medication use, it may be fruitful to examine the content of provider continuing education programs, including the recommendations of major health professional organization guidelines to treat ADHD.

  5. All-magnetic extraction for cyclotron beam reacceleration

    Science.gov (United States)

    Hudson, E.D.; Mallory, M.L.

    1975-07-22

    An isochronous cyclotron can be modified to provide an initial electron stripping stage, a complete acceleration of the stripped ions through the cyclotron to a first energy state, means for returning the ions to an intermediate cyclotron orbit through a second stripping stage, further acceleration of the now higher energy stripped ions through the cyclotron to their final energy, and final extraction of the ions from the cyclotron. (auth)

  6. An empirical assessment of high-performing medical groups: results from a national study.

    Science.gov (United States)

    Shortell, Stephen M; Schmittdiel, Julie; Wang, Margaret C; Li, Rui; Gillies, Robin R; Casalino, Lawrence P; Bodenheimer, Thomas; Rundall, Thomas G

    2005-08-01

    The performance of medical groups is receiving increased attention. Relatively little conceptual or empirical work exists that examines the various dimensions of medical group performance. Using a national database of 693 medical groups, this article develops a scorecard approach to assessing group performance and presents a theory-driven framework for differentiating between high-performing versus low-performing medical groups. The clinical quality of care, financial performance, and organizational learning capability of medical groups are assessed in relation to environmental forces, resource acquisition and resource deployment factors, and a quality-centered culture. Findings support the utility of the performance scorecard approach and identification of a number of key factors differentiating high-performing from low-performing groups including, in particular, the importance of a quality-centered culture and the requirement of outside reporting from third party organizations. The findings hold a number of important implications for policy and practice, and the framework presented provides a foundation for future research.

  7. Method and apparatuses for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2012-03-06

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber. The trapping electric field may comprise a field potential that, when taken in cross-section along the z-axis, includes at least one section that is concave down and at least one section that is concave up so that ions traversing the field potential experience a net magnetron effect on a cyclotron frequency of the ions that is substantially equal to zero. Other apparatuses and a method for performing ion cyclotron spectrometry are also disclosed herein.

  8. NORTICA - a new code for cyclotron analysis

    International Nuclear Information System (INIS)

    Gorelov, D.; Johnson, D.; Marti, F.

    2001-01-01

    The new package NORTICA (Numerical ORbit Tracking In Cyclotrons with Analysis) of computer codes for beam dynamics simulations is under development at NSCL. The package was started as a replacement for the code MONSTER developed in the laboratory in the past. The new codes are capable of beam dynamics simulations in both CCF (Coupled Cyclotron Facility) accelerators, the K500 and K1200 superconducting cyclotrons. The general purpose of this package is assisting in setting and tuning the cyclotrons taking into account the main field and extraction channel imperfections. The computer platform for the package is Alpha Station with UNIX operating system and X-Windows graphic interface. A multiple programming language approach was used in order to combine the reliability of the numerical algorithms developed over the long period of time in the laboratory and the friendliness of modern style user interface. This paper describes the capability and features of the codes in the present state

  9. 10 GHz ECRIS for Warsaw Cyclotron

    CERN Document Server

    Sudlitz, K

    1999-01-01

    Cusp type, 10 GHz ECRIS has been built and tested earlier. For obtaining intensive beams, more relevant for cyclotron, cusp geometry has been replaced by hexapole. Discharge chamber (stainless steel, 50 mm diameter, 250 mm long) is an extension of a coaxial line, feeding RF (9,6 GHz, up to 200 W) to the plasma. The NdFeB hexapole (0,52 T on the surface) has been used. The axial magnetic field is created by water cooled coils. The axial injection line dedicated to K160 isochronous heavy ion cyclotron has been constructed. The line consists of Glaser lenses, double focusing magnet, solenoid and mirror type inflector. The system provides sufficient transmission of the beam from ECR ion source to the firsts orbits of the cyclotron for m/q ranging from 7 to 2. After successful initial tests which were done in July 1997 the ECRIS serves as an external source for Warsaw Cyclotron.

  10. Application of superconductivity in cyclotron construction

    International Nuclear Information System (INIS)

    Blosser, H.G.

    1982-01-01

    This paper reviews major concepts and design features of the new class of cyclotrons which use superconducting coils to provide main magnet excitation. The discussion begins with a brief historical review tracing the evolution of these ''superconducting'' cyclotrons and the impact of this application of superconductivity in pushing back traditional cyclotron construction limits. This is followed by a review of the principal phenomena which come into play to set new limits on the operating regime, and the nature of these limits, some of which arise from orbit properties and some of which result from construction intricacies in the coil and in the rf system. Conclusions anticipate a future widely encompassing role in the application of superconductivity to cyclotron

  11. Progress report: Variable Energy Cyclotron Centre, Calcutta

    International Nuclear Information System (INIS)

    1999-01-01

    This volume of the progress report brings out the scientific and technical activities of Variable Energy Cyclotron Centre, Calcutta during the year 1999. This includes brief review of the various R and D activities of the Centre and outside users of the cyclotron from the universities and other research institutes. The operational activities of the cyclotron with ECR ion sources, accelerator oriented research activities, activities on detector, target and electronics are reported. The activities of the Computer and Informatics group are described. The status report of the ongoing projects is also provided. The main activities of the superconducting cyclotron project, radioactive ion beam project, heavy ion experimental facility, advanced computational facility, recovery and analysis of helium from hot springs and material science research are described

  12. Electron cyclotron emission imaging in tokamak plasmas

    NARCIS (Netherlands)

    Munsat, T.; Domier, C.W.; Kong, X. Y.; Liang, T. R.; N C Luhmann Jr.,; Tobias, B. J.; Lee, W.; Park, H. K.; Yun, G.; Classen, I.G.J.; Donne, A. J. H.

    2010-01-01

    We discuss the recent history and latest developments of the electron cyclotron emission imaging diagnostic technique, wherein electron temperature is measured in magnetically confined plasmas with two-dimensional spatial resolution. The key enabling technologies for this technique are the

  13. Cyclotron method for heavy ion acceleration

    International Nuclear Information System (INIS)

    Gikal, B.N.; Gul'bekyan, G.G.; Kutner, V.B.; Oganesyan, R.Ts.

    1984-01-01

    Studies on heavy ion beams in a wide range of masses (up to uranium) and energies disclose essential potential opportunities for solution of both fundamental scientific and significant economical problems. A cyclotron method for heavy ion acceleration is considered. Development of low and medium energy heavy ion accelerators is revealed. The design of a complex comprising two isochronous cyclotrons which is planned to be constrdcted 1n the JINR is described. The cyclotron complex includes the U-400 and the U-400 M cyclotrons and it is intended for acceleration of both 35-20 MeV/nucleon superheavy ions such as Xe-U and 120 MeV/nucleon light ions. Certain systems of the accelerators are described. Prospects of the U-400 and the U-400 M development are displayed

  14. Public opinion and medical cannabis policies: examining the role of underlying beliefs and national medical cannabis policies

    OpenAIRE

    Sznitman, Sharon R.; Bretteville-Jensen, Anne Line

    2015-01-01

    Background Debate about medical cannabis legalization are typically informed by three beliefs: (1) cannabis has medical effects, (2) medical cannabis is addictive and (3) medical cannabis legalization leads to increased used of cannabis for recreational purposes (spillover effects). We examined how strongly these beliefs are associated with public support for medical cannabis legalization and whether this association differs across divergent medical cannabis policy regimes. Methods Robust reg...

  15. Medical countermeasures for national security: a new government role in the pharmaceuticalization of society.

    Science.gov (United States)

    Elbe, Stefan; Roemer-Mahler, Anne; Long, Christopher

    2015-04-01

    How do governments contribute to the pharmaceuticalization of society? Whilst the pivotal role of industry is extensively documented, this article shows that governments too are accelerating, intensifying and opening up new trajectories of pharmaceuticalization in society. Governments are becoming more deeply invested in pharmaceuticals because their national security strategies now aspire to defend populations against health-based threats like bioterrorism and pandemics. To counter those threats, governments are acquiring and stockpiling a panoply of 'medical countermeasures' such as antivirals, next-generation vaccines, antibiotics and anti-toxins. More than that, governments are actively incentivizing the development of many new medical countermeasures--principally by marshaling the state's unique powers to introduce exceptional measures in the name of protecting national security. At least five extraordinary policy interventions have been introduced by governments with the aim of stimulating the commercial development of novel medical countermeasures: (1) allocating earmarked public funds, (2) granting comprehensive legal protections to pharmaceutical companies against injury compensation claims, (3) introducing bespoke pathways for regulatory approval, (4) instantiating extraordinary emergency use procedures allowing for the use of unapproved medicines, and (5) designing innovative logistical distribution systems for mass drug administration outside of clinical settings. Those combined efforts, the article argues, are spawning a new, government-led and quite exceptional medical countermeasure regime operating beyond the conventional boundaries of pharmaceutical development and regulation. In the first comprehensive analysis of the pharmaceuticalization dynamics at play in national security policy, this article unearths the detailed array of policy interventions through which governments too are becoming more deeply imbricated in the pharmaceuticalization of

  16. Progress report on the Milan superconducting cyclotron

    International Nuclear Information System (INIS)

    Acerbi, E.; Alessandria, F.; Baccaglioni, G.; Bellomo, G.; Birattari, C.; Bosotti, A.; Broggi, F.; Cortesi, G.; DeMartinis, C.; Fabrici, E.; Ferrari, A.; Giove, D.; Giussani, A.; Giussani, W.; Michelato, P.; Pagani, C.; Rivoltella, G.; Rossi, L.; Serafini, L.; Sussetto, A.; Torri, V.; Varisco, G.; Cuttone, G.; Raia, G.; Kai, L.

    1988-01-01

    This paper reports on the construction of the K800 superconducting cyclotron at the University of Milan underway since February 1981. The delay in the construction of the new building and a defect of the weldings of the helium vessel have caused a shift in the project schedule of about two years. Currently, the cyclotron magnet and the cryogenic plant have been completed and installed. First operation of the magnet and magnetic field mapping are to begin shortly

  17. Building 211 cyclotron characterization survey report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-30

    The Building 211 Cyclotron Characterization Survey includes an assessment of the radioactive and chemical inventory of materials stored within the facility; an evaluation of the relative distribution of accelerator-produced activation products within various cyclotron components and adjacent structures; measurement of the radiation fields throughout the facility; measurement and assessment of internal and external radioactive surface contamination on various equipment, facility structures, and air-handling systems; and an assessment of lead (Pb) paint and asbestos hazards within the facility.

  18. NIRS-Chiba isochronous cyclotron 1975

    International Nuclear Information System (INIS)

    Ogawa, H.; Kumamoto, Y.; Yamada, T.; Hiramoto, T.

    1976-02-01

    The cyclotron facility installed according to the recommendation of the Atomic Energy Committee of Japan is used for neutron therapy and production of short-lived radioisotopes. Construction on the facility was started in the autumn of 1972, and completed in March 1974. Described are the following: beam transport and the experimental hall, machine research and improvement, machine time sharing and the particles and energies, characteristics of the cyclotron, and facility personnel. (auth.)

  19. Initial operation of the cyclotron CYTRACK

    International Nuclear Information System (INIS)

    Denisov, Yu.N.; Dolya, S.N.; Kalinichenko, V.V.; Karamysheva, G.A.; Kostromin, S.A.; Fedorenko, S.B.

    2005-01-01

    The industrial cyclotron CYTRACK is dedicated to produce the track membranes. It is the basic instrument for the industry of membrane products to be consumed in medicine, biotechnology, pharmacology, microelectronics and many other industries. Cyclotron CYTRACK started working in August 2002. Argon ions were accelerated to the project energy - 2.4 MeV/nucleon, the extracted beam intensity was about 200 nA, the extraction efficiency totaled ∼50%

  20. Cyclotron beam dynamic simulations in MATLAB

    International Nuclear Information System (INIS)

    Karamysheva, G.A.; Karamyshev, O.V.; Lepkina, O.E.

    2008-01-01

    MATLAB is useful for beam dynamic simulations in cyclotrons. Programming in an easy-to-use environment permits creation of models in a short space of time. Advanced graphical tools of MATLAB give good visualization features to created models. The beam dynamic modeling results with an example of two different cyclotron designs are presented. Programming with MATLAB opens wide possibilities of the development of the complex program, able to perform complete block of calculations for the design of the accelerators

  1. Pediatric Tape: Accuracy and Medication Delivery in the National Park Service

    Directory of Open Access Journals (Sweden)

    Danielle D. Campagne

    2015-10-01

    Full Text Available Introduction: The objective is to evaluate the accuracy of medication dosing and the time to medication administration in the prehospital setting using a novel length-based pediatric emergency resuscitation tape. Methods: This study was a two-period, two-treatment crossover trial using simulated pediatric patients in the prehospital setting. Each participant was presented with two emergent scenarios; participants were randomized to which case they encountered first, and to which case used the National Park Service (NPS emergency medical services (EMS length-based pediatric emergency resuscitation tape. In the control (without tape case, providers used standard methods to determine medication dosing (e.g. asking parents to estimate the patient’s weight; in the intervention (with tape case, they used the NPS EMS length-based pediatric emergency resuscitation tape. Each scenario required dosing two medications (Case 1 [febrile seizure] required midazolam and acetaminophen; Case 2 [anaphylactic reaction] required epinephrine and diphenhydramine. Twenty NPS EMS providers, trained at the Parkmedic/Advanced Emergency Medical Technician level, served as study participants. Results: The only medication errors that occurred were in the control (no tape group (without tape: 5 vs. with tape: 0, p=0.024. Time to determination of medication dose was significantly shorter in the intervention (with tape group than the control (without tape group, for three of the four medications used. In case 1, time to both midazolam and acetaminophen was significantly faster in the intervention (with tape group (midazolam: 8.3 vs. 28.9 seconds, p=0.005; acetaminophen: 28.6 seconds vs. 50.6 seconds, p=0.036. In case 2, time to epinephrine did not differ (23.3 seconds vs. 22.9 seconds, p=0.96, while time to diphenhydramine was significantly shorter in the intervention (with tape group (13 seconds vs. 37.5 seconds, p<0.05. Conclusion: Use of a length-based pediatric emergency

  2. Effective medical treatment of opiate addiction. National Consensus Development Panel on Effective Medical Treatment of Opiate Addiction.

    Science.gov (United States)

    1998-12-09

    To provide clinicians, patients, and the general public with a responsible assessment of the effective approaches to treat opiate dependence. A nonfederal, nonadvocate, 12-member panel representing the fields of psychology, psychiatry, behavioral medicine, family medicine, drug abuse, epidemiology, and the public. In addition, 25 experts from these same fields presented data to the panel and a conference audience of 600. Presentations and discussions were divided into 3 phases over 2 1/2 days: (1) presentations by investigators working in the areas relevant to the consensus questions during a 2-day public session; (2) questions and statements from conference attendees during open discussion periods that are part of the public session; and (3) closed deliberations by the panel during the remainder of the second day and morning of a third day. The conference was organized and supported by the Office of Medical Applications of Research, National Institutes of Health. The literature was searched through MEDLINE and other National Library of Medicine and online databases from January 1994 through September 1997 and an extensive bibliography of 941 references was provided to the panel and the conference audience. Experts prepared abstracts for their presentations as speakers at the conference with relevant citations from the literature. Scientific evidence was given precedence over clinical anecdotal experience. The panel, answering predefined questions, developed its conclusions based on the scientific evidence presented in open forum and the scientific literature. The panel composed a draft statement that was read in its entirety and circulated to the experts and the audience for comment. Thereafter, the panel resolved conflicting recommendations and released a revised statement at the end of the conference. The panel finalized the revisions within a few weeks after the conference. The draft statement was made available on the World Wide Web immediately following its

  3. Motivation of French medical students to pursue surgical careers: results of national survey of 1742 students.

    Science.gov (United States)

    Lefèvre, Jeremie H; Karila, Laurent; Kerneis, Solen; Rouprêt, Morgan

    2010-06-01

    Analyze the aspirations and personal motivations behind the choice of surgical specialties in a large sample of students in their 6th year of medical school. In December 2008, 2588 students participated in a nation-wide mock exam, before taking the National Ranking Exam. When they looked for their grades on the web, the students were prompted to answer a questionnaire containing socio-demographic questions concerning their choice and motivation to pursue a career in a surgical specialty. The survey called also for listing the three main factors (out of a list of 11) motivating their choice. Students originated from 39 medical schools. Of the 2588 students, 1427 (55%) were women. The response rate to the questionnaire was 1742/2588=67%. Two hundred and twenty students (13%) did not express any specific professional orientation. Of the 1522 responses obtained, 522 students wanted to become surgeons. Gender was a determining factor as 44% of male students (n=252) versus 29% of female students wanted to become a surgeon; Pprivate practice (n=280, 18%) and life style (n=175, 11%) were the motivations most often cited to back their choice. One third of medical students want to become surgeons. Feminization, life style and income are the principal factors influencing the choice of the type of surgical subspecialization. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  4. Conceptual design of the RF accelerating cavities for a superconducting cyclotron

    International Nuclear Information System (INIS)

    Maggiore, M.; Calabretta, L.; Di Giacomo, M.; Rifuggiato, D.; Battaglia, D.; Piazza, L.

    2006-01-01

    A superconducting cyclotron accelerating ions up to 250 A MeV, for medical applications and radioactive ions production is being studied at Laboratori Nazionali del Sud in Catania. The radio frequency (RF) system, working in the fourth harmonic, is based on four normal conducting radio frequency cavities operating at 93 MHz. This paper describes an unusual multi-stem cavity design, performed with 3D electromagnetic codes. Our aim is to obtain a cavity, completely housed inside the cyclotron, with a voltage distribution ranging from 65 kV in the injection region to a peak value of 120 kV in the extraction region, and having a low power consumption

  5. Solid targets for production of radioisotopes with cyclotron; Blancos solidos para produccion de radioisotopos con ciclotron

    Energy Technology Data Exchange (ETDEWEB)

    Paredes G, L.; Balcazar G, M. [Instituto Nacional de Investigaciones Nucleares, Direccion de Investigacion Tecnologica, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    The design of targets for production of radioisotopes and radiopharmaceuticals of cyclotron to medical applications requires a detailed analysis of several variables such as: cyclotron operation conditions, choice of used materials as target and their physicochemical characteristics, activity calculation, the yielding of each radioisotope by irradiation, the competition of nuclear reactions in function of the projectiles energy and the collision processes amongst others. The objective of this work is to determine the equations for the calculation for yielding of solid targets at the end of the proton irradiation. (Author)

  6. Sri Lanka's national assessment on innovation and intellectual property for access to medical products.

    Science.gov (United States)

    Beneragama, Hemantha; Shridhar, Manisha; Ranasinghe, Thushara; Dissanayake, Vajira Hw

    2016-09-01

    In 2008, the Global strategy and plan of action on public health, innovation and intellectual property (GSPA-PHI) was launched by the World Health Organization, to stimulate fresh thinking on innovation in, and access to, medicines and to build sustainable research on diseases disproportionately affecting low- and middle-income countries. As part of the activities of the GSPA-PHI, Sri Lanka has been the first country to date to assess the national environment for medical technology and innovation. This year-long, multistakeholder, participative analysis facilitated identification of clear and implementable policy recommendations, for the government to increase its effectiveness in promoting innovation in health products through institutional development, investment and coordination among all areas relevant to public health. The assessment also highlighted areas for priority action, including closing the technology gap in development of health products, facilitating technology transfer, and building the health-research and allied workforces. The Sri Lankan experience will inform the ongoing independent external evaluation of the GSPA-PHI worldwide. The assessment process coincided with the passing of the National Medicines Regulatory Authority Act in 2015. In addition, there is growing recognition that regional cooperation will be critical to improving access to medical products in the future. Sri Lanka is therefore actively promoting cooperation to establish a regional regulatory affairs network. Lessons learnt from the Sri Lankan assessment may also benefit other countries embarking on a national GSPA-PHI assessment.

  7. Establishment of exposure dose assessment laboratory in National Radiation Emergency Medical Center (NREMC)

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jae Ryong; Ha, Wi Ho; Yoon, Seok Won; Han, Eun Ae; Lee, Seung Sook [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2011-10-15

    As unclear industry grown, 432 of the nuclear power plants are operating and 52 of NPPs are under construction currently. Increasing use of radiation or radioisotopes in the field of industry, medical purpose and research such as non-destructive examination, computed tomography and x-ray, etc. constantly. With use of nuclear or radiation has incidence possibility for example the Fukushima NPP incident, the Goiania accident and the Chernobyl Nuclear accident. Also the risk of terror by radioactive material such as Radiological Dispersal Device(RDD) etc. In Korea, since the 'Law on protection of nuclear facilities and countermeasure for radioactive preparedness was enacted in 2003, the Korean institute of Radiological and Medical Sciences(KIRAMS) was established for the radiation emergency medical response in radiological disaster due to nuclear accident, radioactive terror and so on. Especially National Radiation Emergency Medical Center(NREMC) has the duty that is protect citizens from nuclear, radiological accidents or radiological terrors through the emergency medical preparedness. The NREMC was established by the 39-article law on physical protection of nuclear material and facilities and measures for radiological emergencies. Dose assessment or contamination survey should be performed which provide the radiological information for medical response. For this reason, the NREMC establish and re-organized dose assessment system based on the existing dose assessment system of the NREMC recently. The exposure dose could be measured by physical and biological method. With these two methods, we can have conservative dose assessment result. Therefore the NREMC established the exposure dose assessment laboratory which was re-organized laboratory space and introduced specialized equipment for dose assessment. This paper will report the establishment and operation of exposure dose assessment laboratory for radiological emergency response and discuss how to enhance

  8. Personality Traits Are Associated with Academic Achievement in Medical School: A Nationally Representative Study.

    Science.gov (United States)

    Sobowale, Kunmi; Ham, Sandra A; Curlin, Farr A; Yoon, John D

    2018-06-01

    This nationally representative study sought to identify personality traits that are associated with academic achievement in medical school. Third-year medical students, who completed an initial questionnaire in January 2011, were mailed a second questionnaire several months later during their fourth year. Controlling for sociodemographic characteristics and burnout, the authors used multivariate logistic regressions to determine whether Big Five personality traits were associated with receiving honors/highest grade in clinical clerkships, failing a course or rotation, and being selected for the Alpha Omega Alpha or Gold Humanism Honor Society. The adjusted response rates for the two surveys were 61 (n = 564/919) and 84% (n = 474/564). The personality trait conscientiousness predicted obtaining honors/highest grade in all clinical clerkships. In contrast, students high in neuroticism were less likely to do well in most specialties. Students with higher conscientiousness were more likely to be inducted into the Alpha Omega Alpha Honor Society, while students high in openness or agreeableness traits were more likely to be inducted into the Gold Humanism Honor Society. Burnout was not associated with any clinical performance measures. This study suggests the importance of personality traits, particularly conscientiousness, in predicting success during the clinical years of medical school. Medical educators should consider a nuanced examination of personality traits and other non-cognitive factors, particularly for psychiatry.

  9. Creating a Framework for Medical Professionalism: An Initial Consensus Statement From an Arab Nation.

    Science.gov (United States)

    Abdel-Razig, Sawsan; Ibrahim, Halah; Alameri, Hatem; Hamdy, Hossam; Haleeqa, Khaled Abu; Qayed, Khalil I; Obaid, Laila O; Al Fahim, Maha; Ezimokhai, Mutairu; Sulaiman, Nabil D; Fares, Saleh; Al Darei, Maitha Mohammed; Shahin, Nhayan Qassim; Al Shamsi, Noora Abdulla Omran; Alnooryani, Rashed Arif; Al Falahi, Salama Zayed

    2016-05-01

    Background Medical professionalism has received increased worldwide attention, yet there is limited information on the applicability and utility of established Western professionalism frameworks in non-Western nations. Objective We developed a locally derived consensus definition of medical professionalism for the United Arab Emirates (UAE), which reflects the cultural and social constructs of the UAE and the Middle East. Methods We used a purposive sample of 14 physicians working in the UAE as clinical and education leaders. This expert panel used qualitative methods, including the world café, nominal group technique, the Delphi method, and an interpretive thematic analysis to develop the consensus statement. Results The expert panel defined 9 attributes of medical professionalism. There was considerable overlap with accepted Western definitions, along with important differences in 3 aspects: (1) the primacy of social justice and societal rights; (2) the role of the physician's personal faith and spirituality in guiding professional practices; and (3) societal expectations for professional attributes of physicians that extend beyond the practice of medicine. Conclusions Professionalism is a social construct influenced by cultural and religious contexts. It is imperative that definitions of professionalism used in the education of physicians in training and in the assessment of practicing physicians be formulated locally and encompass specific competencies relevant to the local, social, and cultural context for medical practice. Our goal was to develop a secular consensus statement that encompasses culture and values relevant to professionalism for the UAE and the Arab region.

  10. Creating a Framework for Medical Professionalism: An Initial Consensus Statement From an Arab Nation

    Science.gov (United States)

    Abdel-Razig, Sawsan; Ibrahim, Halah; Alameri, Hatem; Hamdy, Hossam; Haleeqa, Khaled Abu; Qayed, Khalil I.; Obaid, Laila O.; Al Fahim, Maha; Ezimokhai, Mutairu; Sulaiman, Nabil D.; Fares, Saleh; Al Darei, Maitha Mohammed; Shahin, Nhayan Qassim; Al Shamsi, Noora Abdulla Omran; Alnooryani, Rashed Arif; Al Falahi, Salama Zayed

    2016-01-01

    Background Medical professionalism has received increased worldwide attention, yet there is limited information on the applicability and utility of established Western professionalism frameworks in non-Western nations. Objective We developed a locally derived consensus definition of medical professionalism for the United Arab Emirates (UAE), which reflects the cultural and social constructs of the UAE and the Middle East. Methods We used a purposive sample of 14 physicians working in the UAE as clinical and education leaders. This expert panel used qualitative methods, including the world café, nominal group technique, the Delphi method, and an interpretive thematic analysis to develop the consensus statement. Results The expert panel defined 9 attributes of medical professionalism. There was considerable overlap with accepted Western definitions, along with important differences in 3 aspects: (1) the primacy of social justice and societal rights; (2) the role of the physician's personal faith and spirituality in guiding professional practices; and (3) societal expectations for professional attributes of physicians that extend beyond the practice of medicine. Conclusions Professionalism is a social construct influenced by cultural and religious contexts. It is imperative that definitions of professionalism used in the education of physicians in training and in the assessment of practicing physicians be formulated locally and encompass specific competencies relevant to the local, social, and cultural context for medical practice. Our goal was to develop a secular consensus statement that encompasses culture and values relevant to professionalism for the UAE and the Arab region. PMID:27168882

  11. Ion-cyclotron-resonance- and Fourier-transform-ion-cyclotron-resonance spectroscopy: technology and application

    International Nuclear Information System (INIS)

    Luederwald, I.

    1977-01-01

    Instrumentation and technology of Ion-Cyclotron-Resonance and Fourier-Transform-Ion-Cyclotron-Resonance Spectroscopy are described. The method can be applied to studies of ion/molecule reactions in gas phase, to obtain thermodynamic data as gas phase acidity or basicity, proton and electron affinity, and to establish reaction mechanisms and ion structures. (orig.) [de

  12. 57 Co produced in cyclotron

    International Nuclear Information System (INIS)

    Landini, Liliane; Osso Junior, Joao Alberto

    2000-01-01

    The Cyclotron CV-28 of IPEN-CNEN/SP is a particle accelerator, used mainly in the radioisotope production, applied in 'in vivo' diagnosis in nuclear medicine. Some of them are employed in the calibration of Diagnosis equipment, such as gamma and X-rays detectors. Co-57 is an example of this application. A natural nickel foil was used as target and irradiated with proton beams of 24 MeV energy. The radioactivity analysis of the irradiated target was performed by Gamma Spectroscopy with a HPGe detector. A 259,74MBq (7,02 mCi) Co-57 source was prepared, 67 days after the last bombardment, with impurity levels of 1.13% for Co-56 and 1.29% for Co-58. The thick target yields for Co-57 and for the main radionuclidic impurities were measured, after the chemical separation of the irradiated target, extrapolated to the last EOB: 1.076 MBq (29.09 mCi)/mA.h, 0.012 MBq (0.33 mCi)/mA.h and 0.014 MBq (0.37 mCi)/mA.h, for Co-57, Co-56 and Co-58, respectively. (author)

  13. Electron cyclotron heating of plasmas

    International Nuclear Information System (INIS)

    Guest, Gareth

    2009-01-01

    As nuclear fusion becomes an increasingly important potential energy source in these times of global oil and energy crises, the development of technologies that can lead to the realization of this virtually inexhaustible source of energy takes on ever greater urgency. Over the past decade electron cyclotron heating has undergone a significant maturation and has emerged as an essential component of the major approaches to achieving controlled nuclear fusion. The gyrotron, first developed in the Soviet Union, has made it possible to employ ECH in large tokamak and stellarator fusion devices by providing megawatts of microwave power at frequencies above 100 GHz. A contemporary VGT-8110 gyrotron, for example, shown here with Kevin Felch and Pat Cahalan of Communications and Power Industries, is capable of delivering 10 second pulses of 1 MW of power at 110 GHz. The present monograph addresses the ECH physics critical to the international fusion reactor experiment, ITER, but also presents the fundamentals of ECH that are essential to its successful implementation in applications that range from active experiments in planetary magnetospheres to commercial plasma sources for the manufacture of computer chips. The book seeks to convey the physics of ECH in an orderly and coherent fashion to a professional audience by presenting the basic theoretical foundations and then using the theory to interpret a number of established experimental results. Exercises are included to aid the reader in making the theory more concrete. (orig.)

  14. Cyclotron tubes - a theoretical study

    Energy Technology Data Exchange (ETDEWEB)

    Mourier, G

    1980-12-01

    The introduction presents a general discussion of electron cyclotron masers (ECM): resonance, relativistic effects, elementary quantum aspects, the classical relativistic bunching and the optimum value of the electric field. The practical structure - in particular that of the gyrotron - is specified only insofar as it is useful for understanding the following chapters. The main parameters are discussed. Section 2 develops a nonlinear adiabatic or orbital theory of electron motion which alleviates calculations considerably while keeping numerical errors low enough for many practical cases. Its results are compared to a rigorous integration in one case. Other cases show the importance of the electric field profile inside the resonant cavity. Section 3 is devoted to space charge phenomena, and, for the most part, to a linear theory with space charge. In its limited range of validity (low-energy electrons), the theory indicates a strong impact of space charge for low a.c. fields and exhibits a pure beam instability. Section 4 is devoted to circuit equations with emphasis on the special features of cavities consisting of a long waveguide near cutoff. The conclusion indicates some trends of gyrotron development and corresponding theoretical problems.

  15. Survey of Medical Oncology Status in Korea (SOMOS-K): A National Survey of Medical Oncologists in the Korean Association for Clinical Oncology (KACO).

    Science.gov (United States)

    Kim, Do Yeun; Lee, Yun Gyoo; Kim, Bong-Seog

    2017-07-01

    This study was conducted to investigate the current role of medical oncologists in cancer care with a focus on increasing the recognition of medical oncology as an independent specialty. Questionnaires modified from the Medical Oncology Status in Europe Survey dealing with oncology structure, resources, research, and patterns of care given by medical oncologists were selected. Several modifications were made to the questionnaire after feedback from the insurance and policy committee of the Korean Association for Clinical Oncology (KACO). The online survey was then sent to KACO members. A total of 214 medical oncologists (45.8% of the total inquiries), including 71 directors of medical oncology institutions, took the survey. Most institutions had various resources, including a medical oncology department (94.1%) and a department of radiation oncology (82.4%). There was an average of four medical oncologists at each institution. Medical oncologists were involved in various treatments from diagnosis to end-of-life care. They were also chemotherapy providers from a wide range of institutions that treated many types of solid cancers. In addition, 86.2% of the institutions conducted research. This is the first national survey in Korea to show that medical oncologists are involved in a wide range of cancer treatments and care. This survey emphasizes the contributions and proper roles of medical oncologists in the evolving health care environment in Korea.

  16. Non-medical use of prescription drugs in a national sample of college women.

    Science.gov (United States)

    McCauley, Jenna L; Amstadter, Ananda B; Macdonald, Alexandra; Danielson, Carla Kmett; Ruggiero, Kenneth J; Resnick, Heidi S; Kilpatrick, Dean G

    2011-07-01

    Non-medical use of prescription drugs (NMUPD) is one of the fastest growing forms of illicit drug use, with research indicating that college students represent a particularly high risk population. The current study examined demographic characteristics, health/mental health, substance misuse, and rape experiences as potential risk correlates of NMUPD among a national sample of college women (N=2000). Interviews were conducted via telephone using Computer-Assisted Telephone Interviewing technology. NMUPD was assessed by asking if, participants had used a prescription drug non-medically in the past year. NMUPD was endorsed by 7.8% of the sample (n=155). Although incapacitated and drug-alcohol facilitated rape were associated with NMUPD in the initial model, the final multivariable model showed that only lifetime major depression and other forms of substance use/abuse were significantly uniquely associated with an increased likelihood of NMUPD. Implications for primary and secondary prevention and subsequent research are addressed. Published by Elsevier Ltd.

  17. General aspects of radiological protection to consider for the licensing a hospital cyclotron

    International Nuclear Information System (INIS)

    Andrada Contardi, F.A.; Fruttero, N.H.; Bozzo, R.H.; Moschella, E.G.

    2010-01-01

    The use of PET/PET-CT studies for a variety of diagnoses has increased significantly on a global scale. Modern medical cyclotrons must be placed in or near hospitals on account of the short radioactive half-life of the pharmaceuticals used in such studies. Many countries in Latin America are now licensing cyclotrons and laboratories for the production of radio-pharmaceuticals for the first time, and most are expected to have installations within the near future. This report outlines the general aspects of radiological protection important to consideration during the licensing of these facilities, and includes the following: general operation of the cyclotron and laboratory for the production of radiopharmaceuticals, safety systems (shielding, interlocks, ventilation, manual safety systems, alarms and monitors), and general aspects for licensing an installation (monitoring, accidental and incidental events, activation of components, etc.) and personnel. (authors) [es

  18. Design study of an ultra-compact superconducting cyclotron for isotope production

    Science.gov (United States)

    Smirnov, V.; Vorozhtsov, S.; Vincent, J.

    2014-11-01

    A 12.5 MeV, 25 μA, proton compact superconducting cyclotron for medical isotope production has been designed and is currently in fabrication. The machine is initially aimed at producing 13N ammonia for Positron Emission Tomography (PET) cardiology applications. With an ultra-compact size and cost-effective price point, this system will offer clinicians unprecedented access to the preferred radiopharmaceutical isotope for cardiac PET imaging. A systems approach that carefully balanced the subsystem requirements coupled to precise beam dynamics calculations was followed. The system is designed to irradiate a liquid target internal to the cyclotron and to minimize the need for radiation shielding. The main parameters of the cyclotron, its design, and principal steps of the development work are presented here.

  19. Focusing and bunching of ion beam in axial injection channel of IPHC cyclotron TR24

    Science.gov (United States)

    Adam, T.; Ivanenko, I.; Kazarinov, N.; Osswald, F.; Traykov, E.

    2017-07-01

    The CYRCe cyclotron (CYclotron pour la ReCherche et l’Enseignement) is used at IPHC (Institut Pluridisciplinaire Hubert Curien) for the production of radio-isotopes for diagnostics, medical treatments and fundamental research in radiobiology. The TR24 cyclotron produced and commercialized by ACSI (Canada) delivers a 16-25 MeV proton beam with intensity from few nA up to 500 μA. The solenoidal focusing instead of existing quadrupole one is proposed in this report. The changing of the focusing elements will give the better beam matching with the acceptance of the spiral inflector of the cyclotron. The parameters of the focusing solenoid are found. Additionally, the main parameters of the bunching system are evaluated in the presence of the beam space charge. This system consists of the buncher installed in the axial injection beam line of the cyclotron. The using of the grid-less multi harmonic buncher may increase the accelerated beam current and will give the opportunity to new proton beam applications.

  20. 75 FR 69129 - Proposed Revision of Information Collection: Comment Request National Medical Support Notice-Part B

    Science.gov (United States)

    2010-11-10

    ... DEPARTMENT OF LABOR Employee Benefits Security Administration Proposed Revision of Information Collection: Comment Request National Medical Support Notice--Part B AGENCY: Employee Benefits Security... assess the impact of its collection requirements on respondents. Currently, the Employee Benefits...

  1. Status of ion sources at National Institute of Radiological Sciences.

    Science.gov (United States)

    Kitagawa, A; Fujita, T; Goto, A; Hattori, T; Hamano, T; Hojo, S; Honma, T; Imaseki, H; Katagiri, K; Muramatsu, M; Sakamoto, Y; Sekiguchi, M; Suda, M; Sugiura, A; Suya, N

    2012-02-01

    The National Institute of Radiological Sciences (NIRS) maintains various ion accelerators in order to study the effects of radiation of the human body and medical uses of radiation. Two electrostatic tandem accelerators and three cyclotrons delivered by commercial companies have offered various life science tools; these include proton-induced x-ray emission analysis (PIXE), micro beam irradiation, neutron exposure, and radioisotope tracers and probes. A duoplasmatron, a multicusp ion source, a penning ion source (PIG), and an electron cyclotron resonance ion source (ECRIS) are in operation for these purposes. The Heavy-Ion Medical Accelerator in Chiba (HIMAC) is an accelerator complex for heavy-ion radiotherapy, fully developed by NIRS. HIMAC is utilized not only for daily treatment with the carbon beam but also for fundamental experiments. Several ECRISs and a PIG at HIMAC satisfy various research and clinical requirements.

  2. RECALMIN: The association between management of Spanish National Health Service Internal Medical Units and health outcomes.

    Science.gov (United States)

    Zapatero-Gaviria, Antonio; Javier Elola-Somoza, Francisco; Casariego-Vales, Emilio; Fernandez-Perez, Cristina; Gomez-Huelgas, Ricardo; Bernal, José Luis; Barba-Martín, Raquel

    2017-08-01

    To investigate the association between management of Internal Medical Units (IMUs) with outcomes (mortality and length of stay) within the Spanish National Health Service. Data on management were obtained from a descriptive transversal study performed among IMUs of the acute hospitals. Outcome indicators were taken from an administrative database of all hospital discharges from the IMUs. Spanish National Health Service. One hundred and twenty-four acute general hospitals with available data of management and outcomes (401 424 discharges). IMU risk standardized mortality rates were calculated using a multilevel model adjusted by Charlson Index. Risk standardized myocardial infarction and heart failure mortality rates were calculated using specific multilevel models. Length of stay was adjusted by complexity. Greater hospital complexity was associated with longer average length of stays (r: 0.42; P International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  3. The Midwest Proton Radiation Institute project at the Indiana University Cyclotron Facility

    Energy Technology Data Exchange (ETDEWEB)

    Anferov, V; Broderick, B; Collins, J C; Friesel, D L; Jenner, D; Jones, W P; Katuin, J; Klein, S B; Starks, W; Self, J; Schreuder, N [IUCF, Bloomington, Indiana 47408 (United States)

    2001-12-12

    The IUCF cyclotrons ceased delivering particle beams for physics research and became dedicated medical proton beam accelerators in 1999. Removal of the beam lines and nuclear research facilities associated with the cyclotrons to make room for the new medical beam delivery systems was completed in October, 2000. A new achromatic beam line was completed, extending from the main stage cyclotron and ending at a temporary research platform. This beam line is being commissioned during ongoing applied research. The achromatic line will deliver 0.5 {mu}A of 205 MeV protons from which the treatment room technician may draw current at any time via fast switching, laminated magnets located at the entrances to the energy selection systems upstream of each of the treatment rooms. Three treatment rooms are planned, one containing two fixed horizontal lines and two gantry rooms. The cyclotrons will also support full time research in radiation effects, single event upset, radiation biology and pre-clinical research. This contribution describes the status of the medical construction project.

  4. National Trends in the Utilization of Emergency Medical Services for Acute Myocardial Infarction and Stroke

    Directory of Open Access Journals (Sweden)

    Katie Tataris

    2014-11-01

    Full Text Available Introduction: The emergency medical services (EMS system plays a crucial role in the chain of survival for acute myocardial infarction (AMI and stroke. While regional studies have shown underutilization of the 911 system for these time-sensitive conditions, national trends have not been studied. Our objective was to describe the national prevalence of EMS use for AMI and stroke, examine trends over a six-year period, and identify patient factors that may contribute to utilization. Methods: Using the National Hospital Ambulatory Medical Care Survey-ED (NHAMCS dataset from 2003-2009, we looked at patients with a discharge diagnosis of AMI or stroke who arrived to the emergency department (ED by ambulance. We used a survey-weighted χ2 test for trend and logistic regression analysis. Results: In the study, there were 442 actual AMI patients and 220 (49.8% presented via EMS. There were 1,324 actual stroke patients and 666 (50.3% presented via EMS. There was no significant change in EMS usage for AMI or stroke over the six-year period. Factors independently associated with EMS use for AMI and stroke included age (OR 1.21; 95% CI 1.12-1.31, Non-Hispanic black race (OR 1.72; 95% CI 1.16-2.29, and nursing home residence (OR 11.50; 95% CI 6.19-21.36. Conclusion: In a nationally representative sample of ED visits from 20003-2009, there were no trends of increasing EMS use for AMI and stroke. Efforts to improve access to care could focus on patient groups that underutilize the EMS system for such conditions. [West J Emerg Med. 2014;15(7:–0.

  5. The 88-Inch Cyclotron: A One-Stop Facility for Electronics Radiation and Detector Testing

    Energy Technology Data Exchange (ETDEWEB)

    Kireeff Covo, M.; Albright, R. A.; Ninemire, B. F.; Johnson, M. B.; Hodgkinson, A.; Loew, T.; Benitez, J. Y.; Todd, D. S.; Xie, D. Z.; Perry, T.; Phair, L.; Bernsteiny, L. A.; Bevins, J.; Brown, J. A.; Goldblum, B. L.; Harasty, M.; Harrig, K. P.; Laplace, T. A.; Matthews, E. F.; Bushmaker, A.; Walker, D.; Oklejas, V.; Hopkins, A. R.; Bleuel, D. L.; Chen, J.; Cronin, S. B.

    2017-10-01

    In outer space down to the altitudes routinely flown by larger aircrafts, radiation can pose serious issues for microelectronics circuits. The 88-Inch Cyclotron at Lawrence Berkeley National Laboratory is a sector-focused cyclotron and home of the Berkeley Accelerator Space Effects Facility, where the effects of energetic particles on sensitive microelectronics are studied with the goal of designing electronic systems for the space community. This paper describes the flexibility of the facility and its capabilities for testing the bombardment of electronics by heavy ions, light ions, and neutrons. Experimental capabilities for the generation of neutron beams from deuteron breakups and radiation testing of carbon nanotube field effect transistor will be discussed.

  6. Modernising the regulation of medical migration: moving from national monopolies to international markets

    Science.gov (United States)

    2012-01-01

    Background Traditional top-down national regulation of internationally mobile doctors and nurses is fast being rendered obsolete by the speed of globalisation and digitisation. Here we propose a bottom-up system in which responsibility for hiring and accrediting overseas staff begins to be shared by medical employers, managers, and insurers. Discussion In this model, professional Boards would retain authority for disciplinary proceedings in response to local complaints, but would lose their present power of veto over foreign practitioners recruited by employers who have independently evaluated and approved such candidates' ability. Evaluations of this kind could be facilitated by globally accessible National Registers of professional work and conduct. A decentralised system of this kind could also dispense with time-consuming national oversight of continuing professional education and license revalidation, which tasks could be replaced over time by tighter institutional audit supported by stronger powers to terminate underperforming employees. Summary Market forces based on the reputation (and, hence, financial and political viability) of employers and institutions could continue to ensure patient safety in the future, while at the same time improving both national system efficiency and international professional mobility. PMID:23039098

  7. Modernising the regulation of medical migration: moving from national monopolies to international markets

    Directory of Open Access Journals (Sweden)

    Epstein Richard J

    2012-10-01

    Full Text Available Abstract Background Traditional top-down national regulation of internationally mobile doctors and nurses is fast being rendered obsolete by the speed of globalisation and digitisation. Here we propose a bottom-up system in which responsibility for hiring and accrediting overseas staff begins to be shared by medical employers, managers, and insurers. Discussion In this model, professional Boards would retain authority for disciplinary proceedings in response to local complaints, but would lose their present power of veto over foreign practitioners recruited by employers who have independently evaluated and approved such candidates' ability. Evaluations of this kind could be facilitated by globally accessible National Registers of professional work and conduct. A decentralised system of this kind could also dispense with time-consuming national oversight of continuing professional education and license revalidation, which tasks could be replaced over time by tighter institutional audit supported by stronger powers to terminate underperforming employees. Summary Market forces based on the reputation (and, hence, financial and political viability of employers and institutions could continue to ensure patient safety in the future, while at the same time improving both national system efficiency and international professional mobility.

  8. Modernising the regulation of medical migration: moving from national monopolies to international markets.

    Science.gov (United States)

    Epstein, Richard J; Epstein, Stephen D

    2012-10-05

    Traditional top-down national regulation of internationally mobile doctors and nurses is fast being rendered obsolete by the speed of globalisation and digitisation. Here we propose a bottom-up system in which responsibility for hiring and accrediting overseas staff begins to be shared by medical employers, managers, and insurers. In this model, professional Boards would retain authority for disciplinary proceedings in response to local complaints, but would lose their present power of veto over foreign practitioners recruited by employers who have independently evaluated and approved such candidates' ability. Evaluations of this kind could be facilitated by globally accessible National Registers of professional work and conduct. A decentralised system of this kind could also dispense with time-consuming national oversight of continuing professional education and license revalidation, which tasks could be replaced over time by tighter institutional audit supported by stronger powers to terminate underperforming employees. Market forces based on the reputation (and, hence, financial and political viability) of employers and institutions could continue to ensure patient safety in the future, while at the same time improving both national system efficiency and international professional mobility.

  9. Innovative Approaches To Educating Medical Students for Practice in a Changing Health Care Environment: The National UME-21 Project.

    Science.gov (United States)

    Rabinowitz, Howard K.; Babbott, David; Bastacky, Stanford; Pascoe, John M.; Patel, Kavita K.; Pye, Karen L.; Rodak, John, Jr.; Veit, Kenneth J.; Wood, Douglas L.

    2001-01-01

    Describes the major curriculum changes that have been implemented through Undergraduate Medical Education for the 21st Century (UME-21), a 3-year national demonstration project to encourage innovation in medical education. Discusses challenges that occurred in carrying out those changes, and outlines the strategies for evaluating the project. (EV)

  10. [The keys to success in French Medical National Ranking Examination: Integrated training activities in teaching hospital and medical school].

    Science.gov (United States)

    Gillois, Pierre; Fourcot, Marie; Genty, Céline; Morand, Patrice; Bosson, Jean-Luc

    2015-12-01

    The National Ranking Examination (NRE) is the key to the choice of career and specialty for future physicians; it lets them choose their place of employment in a specialty and an hospital for their internship. It seems interesting to model the success factors to this exam for the medical students from Grenoble University. For each of the medical students at Grenoble University who did apply to the NRE in 2012, data have been collected about their academic background and personal details from the administration of the University. A simple logistic regression with success set as being ranked in the first 2000 students, then a polytomous logistic regression, have been performed. The 191 students in the models are 59% female, 25 years old in average (SD 1.8). The factors associated to a ranking in the first 2000 are: not repeating the PCEM1 class (odds ratio [OR] 2.63, CI95: [1.26; 5.56]), performing nurse practice during internships (OR=1.27 [1.00; 1.62]), being ranked in the first half of the class for S3 pole (OR=6.04 [1.21; 30.20] for the first quarter, OR=5.65 [1.15; 27.74] for the second quarter) and being in the first quarter at T5 pole (OR=3.42 [1.08; 10.82]). Our study finds four factors independently contributing to the success at NRE: not repeating PCEM1, performing nurse practice and being ranked in the top of the class at certain academic fields. The AUC is 0.76 and student accuracy is more than 80%. However, some items, for example repeating DCEM4 or participating in NRE mock exams, have no influence on success. A different motivation should be a part of the explanation… As these analysed data are mainly institutional, they are accurate and reliable. The polytomic logistic model, sharing 3 factors with the simple logistic model, replace a performing nurse practice factor's by a grant recipient factor. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  11. 83-inch cyclotron research program. Final report

    International Nuclear Information System (INIS)

    Parkinson, W.C.

    1983-07-01

    In June of 1960 the US Atomic Energy Commission authorized the construction of a modern variable energy cyclotron facility at The University of Michigan to be used for research in nuclear spectroscopy. The Legislature of the State of Michigan made available funds for construction of a building to house the 83-inch cyclotron and auxiliary equipment as well as the University's remodeled 42-inch cyclotron. The research program centered around the 83-inch cyclotron was funded by the AEC and its successors, the Energy Research and Development Administration (ERDA) and the Department of Energy (DOE), from September 1964 through March 1977. The program represented a continuation of the research effort using the 42-inch cyclotron facility which had been supported continuously by the AEC since February 1950. This final report to DOE briefly describes the research facility, the research program, and highlights the principal accomplishments of the effort. It begins with a historical note to place this effort within the context of nuclear physics research in the Department of Physics of the University of Michigan

  12. Low energy cyclotron for radiocarbon dating

    International Nuclear Information System (INIS)

    Welch, J.J.

    1984-12-01

    The measurement of naturally occurring radioisotopes whose half lives are less than a few hundred million years but more than a few years provides information about the temporal behavior of geologic and climatic processes, the temporal history of meteoritic bodies as well as the production mechanisms of these radioisotopes. A new extremely sensitive technique for measuring these radioisotopes at tandem Van de Graaff and cyclotron facilities has been very successful though the high cost and limited availability have been discouraging. We have built and tested a low energy cyclotron for radiocarbon dating similar in size to a conventional mass spectrometer. These tests clearly show that with the addition of a conventional ion source, the low energy cyclotron can perform the extremely high sensitivity 14 C measurements that are now done at accelerator facilities. We found that no significant background is present when the cyclotron is tuned to accelerate 14 C negative ions and the transmission efficiency is adequate to perform radiocarbon dating on milligram samples of carbon. The internal ion source used did not produce sufficient current to detect 14 C directly at modern concentrations. We show how a conventional carbon negative ion source, located outside the cyclotron magnet, would produce sufficient beam and provide for quick sampling to make radiocarbon dating milligram samples with a modest laboratory instrument feasible

  13. Recycling and recommissioning a used biomedical cyclotron

    International Nuclear Information System (INIS)

    Carroll, L.R.; Ramsey, F.; Armbruster, J.; Montenero, M.

    2001-01-01

    Biomedical Cyclotrons have a very long life, but there eventually comes a time when any piece of equipment has to be retired from service. From time to time, we have the opportunity to help find new homes for used cyclotrons which, with relatively modest overhaul and refurbishment, can have many additional years of productive service, and thus represent a very valuable asset. The reasons for retiring a cyclotron vary, of course, but in our experience it is often due to an institution's changing priorities or changing needs, rather than the due to any fundamental age-related deficiency in the cyclotron itself. In this paper we will report on the relocation and successful restoration of a used TCC CP-42 cyclotron, which was moved from M.D. Anderson Hospital in Houston to Denton, Texas in early 1998, where it is presently being used for R and D and commercial production of biomedical isotopes. Ownership of the machine has been transferred to the University of North Texas; facility, manpower, and operational resources are provided by International Isotopes, Inc

  14. Superconducting cyclotron magnet coil short

    International Nuclear Information System (INIS)

    Mallory, M.L.; Blosser, H.G.; Clark, D.J.; Launer, H.; Lawton, D.; Miller, P.; Resmini, F.

    1982-01-01

    In February 1981, a short circuit appeared in the superconducting coil of the K500 cyclotron. The short is resistive in character and therefore has no effect on steady state operation of the magnet. The resistance of the short varies, sometimes being below threshold of detection as a heat load on the cooling system and sometimes being significant. The resistance under certain conditions shows approximately cyclic phenomena with time constants in the range of seconds and other approximately cyclic phenomena which correlate with gross operating parameters of the magnet (shifting current from one coil to another at high field and lowering and raising the liquid helium level). A number of diagnostic studies of the short have been made, using 1) an array of flux sensing loops to sense the magnetic effect of the short, 2) voltage comparisons between upper and lower sections of the coil, 3) comparisons of forces in the nine member coil support system and 4) the effect of the short on the thermal charactersitics of the coil. Insulation failure or a metal chip shorting out turns have been explored in some detail but a convincing determination of the exact cause of the short may never be available, (even the extreme step of unwinding the coil having a significant probability that an imperfection with the observed characteristics would pass unnoticed). Analysis of the characteristics of the short indicated that the most serious consequence would be failure of the coils mechanical support system in the event that the magnet was quickly discharged, as in a dump or quench. To deal with this hazard, the support system has been modified by installing solid supports which prevent the coil from moving by an amount sufficient to damage the support system. We have also reexamined the data and calculations used in the original coil design and have made some additional measurements of the properties of the materials (yield strength, friction coefficient, Young's modulus) used in the

  15. Preparation and medical outcomes of Nepalese staff and porters compared with foreign nationals on the Annapurna trekking circuit.

    Science.gov (United States)

    Drew, Christian M; Colleran, Shane; Zijp, Maarten; Lama, Lama Phuri; Sherpa, Nuru J; Kelly, Julia L; Sulzbach, Nina; Prior, Denise; Currin, Sally A; Currin, Simon; Nickol, Annabel H; Morrell, Mary J

    2011-01-01

    This cross-sectional study investigates preparedness and medical problems in Nepalese staff and porters compared with foreign nationals trekking at altitude in the Nepal Himalaya. 331 Nepalese and 338 foreign nationals in 61 trekking groups were surveyed over 4 weeks on the Annapurna trekking circuit. Foreign nationals reported that 92% of trekking groups received altitude illness information and carried a medical kit. However, fewer than 30% knew the evacuation insurance status of the Nepalese staff and porters on their trek, 39% would not pay for an ill Nepalese national's helicopter evacuation, and 41% reported insufficient resources to carry an individual. Medical problems occurred in 44% of groups. A significantly higher proportion of Nepalese staff and porters were evacuated compared with foreign nationals. No significant differences in Nepalese and foreign national preparation were found between groups with and without medical problems. Medical problems were commonly encountered, yet many groups lacked resources to evacuate someone dangerously ill. Foreign and Nepalese nationals have a duty of care towards each other; recognizing that preparedness relies not only on a first aid kit, but also on knowledge of acclimatization and individuals' insurance is an important part of health and safety for individuals trekking at altitude.

  16. [Assessment of medical management of heart failure at National Hospital Blaise COMPAORE].

    Science.gov (United States)

    Kambiré, Y; Konaté, L; Diallo, I; Millogo, G R C; Kologo, K J; Tougouma, J B; Samadoulougou, A K; Zabsonré, P

    2018-05-09

    The aim of this study was to assess the quality of medical management of heart failure at the National Hospital Blaise Compaoré according to the international guidelines. A retrospective study was performed including consecutive patients admitted for heart failure documented sonographically from October 2012 to March 2015 in the Medicine and Medical Specialties Department of National Hospital Blaise Compaore with a minimum follow-up of six weeks. Data analysis was made by the SPSS 20.0 software. Eighty-four patients, mean age of 57.61±18.24 years, were included. It was an acute heart failure in 84.5% of patients with systolic left ventricular function impaired (77.4%). The rate of prescription of different drugs in heart failure any type was 88.1% for loop diuretics; 77.1% for angiotensin-converting enzyme inhibitors/angiotensin receptor blockers and 65.5% for betablockers. In patients with systolic dysfunction, 84.62% of patients were received the combination of angiotensin-converting enzyme inhibitors/angiotensin receptor blockers and 75.38% for betablockers. Exercise rehabilitation was undergoing in 10.7% of patients. The death rate was 16.7% and hospital readmission rate of 16.7%. The prescription rate of major heart failure drugs is satisfactory. Cardiac rehabilitation should be developed. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  17. Integration of Tactical Emergency Casualty Care Into the National Tactical Emergency Medical Support Competency Domains.

    Science.gov (United States)

    Pennardt, Andre; Callaway, David W; Kamin, Rich; Llewellyn, Craig; Shapiro, Geoff; Carmona, Philip A; Schwartz, Richard B

    2016-01-01

    Tactical emergency medical support (TEMS) is a critical component of the out-of-hospital response to domestic high-threat incidents such as hostage scenarios, warrant service, active shooter or violent incidents, terrorist attacks, and other intentional mass casualty-producing acts. From its grass-roots inception in the form of medical support of select law enforcement special weapons and tactics (SWAT) units in the 1980s, the TEMS subspecialty of prehospital care has rapidly grown and evolved over the past 40 years. The National TEMS Initiative and Council (NTIC) competencies and training objectives are the only published recommendations of their kind and offer the opportunity for national standardization of TEMS training programs and a future accreditation process. Building on the previous work of the NTIC and the creation of acknowledged competency domains for TEMS and the acknowledged civilian translation of TCCC by the Committee for Tactical Emergency Casualty Care (C-TECC), the Joint Review Committee (JRC) has created an opportunity to bring forward the work in a form that could be operationally useful in an all-hazards and whole of community format. 2016.

  18. Nonmelanoma skin cancer visits and procedure patterns in a nationally representative sample: national ambulatory medical care survey 1995-2007.

    Science.gov (United States)

    Wysong, Ashley; Linos, Eleni; Hernandez-Boussard, Tina; Arron, Sarah T; Gladstone, Hayes; Tang, Jean Y

    2013-04-01

    The rising incidence of nonmelanoma skin cancer (NMSC) is well documented, but data are limited on the number of visits and treatment patterns of NMSC in the outpatient setting. To evaluate practice and treatment patterns of NMSC in the United States over the last decade and to characterize differences according to sex, age, race, insurance type, and physician specialty. Adults with an International Classification of Diseases, Ninth Revision, diagnosis of NMSC were included in this cross-sectional survey study of the National Ambulatory Medical Care Survey between 1995 and 2007. Primary outcomes included population-adjusted NMSC visit rates and odds ratios of receiving a procedure for NMSC using logistic regression. Rates of NMSC visits increased between 1995 and 2007. The number of visits was significantly higher in men, particularly those aged 65 and older. Fifty-nine percent of NMSC visits were associated with a procedure, and the individuals associated with that visit were more likely to be male, to be seen by a dermatologist, and to have private-pay insurance. Nonmelanoma skin cancer visit rates increased from 1995 to 2007 and were higher in men than women. Visits to a dermatologist are more likely to be associated with a procedure for NMSC, and there may be discrepancies in treatment patterns based on insurance type and sex. © 2013 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  19. Croatian Society of Medical Biochemistry and Laboratory Medicine: national recommendations for venous blood sampling.

    Science.gov (United States)

    Nikolac, Nora; Supak-Smolcić, Vesna; Simundić, Ana-Maria; Celap, Ivana

    2013-01-01

    Phlebotomy is one of the most complex medical procedures in the diagnosis, management and treatment of patients in healthcare. Since laboratory test results are the basis for a large proportion (60-80%) of medical decisions, any error in the phlebotomy process could have serious consequences. In order to minimize the possibility of errors, phlebotomy procedures should be standardised, well-documented and written instructions should be available at every workstation. Croatia is one of the few European countries that have national guidelines for phlebotomy, besides the universally used CLSI (Clinical Laboratory Standards Institute) H3-A6 Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; approved Standard-Sixth Edition (CLSI, 2007) and WHO (World Health Organization) guidelines on drawing blood: best practices in phlebotomy (WHO, 2010). However, the growing body of evidence in importance of preanalytical phase management resulted in a need for evidence based revision and expansion of existing recommendations. The Croatian Society for Medical Biochemistry and Laboratory Medicine, Working Group for the Preanalytical Phase issued this recommendation. This document is based on the CLSI guideline H3-A6, with significant differences and additional information.

  20. Utilizing national and international registries to enhance pre-market medical device regulatory evaluation.

    Science.gov (United States)

    Yue, Lilly Q; Campbell, Gregory; Lu, Nelson; Xu, Yunling; Zuckerman, Bram

    2016-01-01

    Regulatory decisions are made based on the assessment of risk and benefit of medical devices at the time of pre-market approval and subsequently, when post-market risk-benefit balance needs reevaluation. Such assessments depend on scientific evidence obtained from pre-market studies, post-approval studies, post-market surveillance studies, patient perspective information, as well as other real world data such as national and international registries. Such registries provide real world evidence and are playing a more and more important role in enhancing the safety and effectiveness evaluation of medical devices. While these registries provide large quantities of data reflecting real world practice and can potentially reduce the cost of clinical trials, challenges arise concerning (1) data quality adequate for regulatory decision-making, (2) bias introduced at every stage and aspect of study, (3) scientific validity of study designs, and (4) reliability and interpretability of study results. This article will discuss related statistical and regulatory challenges and opportunities with examples encountered in medical device regulatory reviews.

  1. Female military medical school graduates entering surgical internships: are we keeping up with national trends?

    Science.gov (United States)

    Vertrees, Amy; Laferriere, Nicole; Elster, Eric; Shriver, Craig D; Rich, Norman M

    2014-10-01

    Ratios of women graduating from the only US military medical school and entering surgical internships were reviewed and compared with national trends. Data were obtained from the Uniformed Services University of the Health Sciences graduation announcements from 2002 to 2012. There were 1,771 graduates from 2002 to 2012, with 508 female (29%) and 1,263 male (71%) graduates. Female graduates increased over time (21% to 39%; P = .014). Female general surgery interns increased from 3.9% to 39% (P = .025). Female overall surgical subspecialty interns increased from 20% in 2002 to 36% in 2012 (P = .046). Women were represented well in obstetrics (57%), urology (44%), and otolaryngology (31%), but not in neurosurgery, orthopedics, and ophthalmology (0% to 20%). The sex disparity between military and civilian medical students occurs before entry. Once in medical school, women are just as likely to enter general surgery or surgical subspecialty as their male counterparts. Increased ratio of women in the class is unlikely to lead to a shortfall except in specific subspecialties. Published by Elsevier Inc.

  2. Perspectives on the value of advanced medical imaging: a national survey of primary care physicians.

    Science.gov (United States)

    Hughes, Christine M; Kramer, Erich; Colamonico, Jennifer; Duszak, Richard

    2015-05-01

    To understand perceptions of primary care physicians (PCPs) about the value of advanced medical imaging. A national quantitative survey of 500 PCPs was conducted using an online self-administered questionnaire. Questions focused on advanced medical imaging (CT, MRI, and PET) and its perceived impact on the delivery of patient care. Responses were stratified by physician demographics. Large majorities of the PCPs indicated that advanced imaging increases their diagnostic confidence (441; 88%); provides data not otherwise available (451; 90%); permits better clinical decision making (440; 88%); increases confidence in treatment choices (438; 88%), and shortens time to definitive diagnosis (430; 86%]). Most (424; 85%) believe that patient care would be negatively affected without access to advanced imaging. PCPs whose clinical careers predated the proliferation of advanced imaging modalities (>20 years of practice) assigned higher value to advanced imaging on several dimensions compared with younger physicians whose training overlapped widespread technology availability. By a variety of metrics, large majorities of PCPs believe that advanced medical imaging provides considerable value to patient care. Those whose careers predated the widespread availability of advanced imaging tended to associate it with even higher value. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. Intensity limits of the PSI Injector II cyclotron

    Science.gov (United States)

    Kolano, A.; Adelmann, A.; Barlow, R.; Baumgarten, C.

    2018-03-01

    We investigate limits on the current of the PSI Injector II high intensity separate-sector isochronous cyclotron, in its present configuration and after a proposed upgrade. Accelerator Driven Subcritical Reactors, neutron and neutrino experiments, and medical isotope production all benefit from increases in current, even at the ∼ 10% level: the PSI cyclotrons provide relevant experience. As space charge dominates at low beam energy, the injector is critical. Understanding space charge effects and halo formation through detailed numerical modelling gives clues on how to maximise the extracted current. Simulation of a space-charge dominated low energy high intensity (9.5 mA DC) machine, with a complex collimator set up in the central region shaping the bunch, is not trivial. We use the OPAL code, a tool for charged-particle optics calculations in large accelerator structures and beam lines, including 3D space charge. We have a precise model of the present (production) Injector II, operating at 2.2 mA current. A simple model of the proposed future (upgraded) configuration of the cyclotron is also investigated. We estimate intensity limits based on the developed models, supported by fitted scaling laws and measurements. We have been able to perform more detailed analysis of the bunch parameters and halo development than any previous study. Optimisation techniques enable better matching of the simulation set-up with Injector II parameters and measurements. We show that in the production configuration the beam current scales to the power of three with the beam size. However, at higher intensities, 4th power scaling is a better fit, setting the limit of approximately 3 mA. Currents of over 5 mA, higher than have been achieved to date, can be produced if the collimation scheme is adjusted.

  4. Statistical fluctuations in cooperative cyclotron radiation

    Science.gov (United States)

    Anishchenko, S. V.; Baryshevsky, V. G.

    2018-01-01

    Shot noise is the cause of statistical fluctuations in cooperative cyclotron radiation generated by an ensemble of electrons oscillating in magnetic field. Autophasing time - the time required for the cooperative cyclotron radiation power to peak - is the critical parameter characterizing the dynamics of electron-oscillators interacting via the radiation field. It is shown that premodulation of charged particles leads to a considerable narrowing of the autophasing time distribution function for which the analytic expression is obtained. When the number of particles Ne exceeds a certain value that depends on the degree to which the particles have been premodulated, the relative root-mean-square deviation (RMSD) of the autophasing time δT changes from a logarithmic dependence on Ne (δT ∼ 1 / lnNe) to square-root (δT ∼ 1 /√{Ne }). A slight energy spread (∼4%) results in a twofold drop of the maximum attainable power of cooperative cyclotron radiation.

  5. Scientific instruments, scientific progress and the cyclotron

    International Nuclear Information System (INIS)

    Baird, David; Faust, Thomas

    1990-01-01

    Philosophers speak of science in terms of theory and experiment, yet when they speak of the progress of scientific knowledge they speak in terms of theory alone. In this article it is claimed that scientific knowledge consists of, among other things, scientific instruments and instrumental techniques and not simply of some kind of justified beliefs. It is argued that one aspect of scientific progress can be characterized relatively straightforwardly - the accumulation of new scientific instruments. The development of the cyclotron is taken to illustrate this point. Eight different activities which promoted the successful completion of the cyclotron are recognised. The importance is in the machine rather than the experiments which could be run on it and the focus is on how the cyclotron came into being, not how it was subsequently used. The completed instrument is seen as a useful unit of scientific progress in its own right. (UK)

  6. Radiation exposure to workers at cyclotron facilities

    International Nuclear Information System (INIS)

    Ribeiro, M.S.; Sanches, M.P.; Sanchez, A.S.; Rodrigues, D.L.

    2001-01-01

    Radiopharmaceuticals quickly furnish the information doctors need to establish a precise diagnosis of the patient's condition, and therefore to prescribe the most effective therapy. In cancerology, F18-FDG, the most widely used PET imaging tracer, excels in the early detection of cancer tumors, even very tiny ones, which it locates and clearly distinguishes from healthy surrounding tissues. IPEN-CNEN/SP has two cyclotron accelerators used mainly for radioisotope production to be utilized in nuclear medicine for diagnosis and therapy. The first is a CV-28 cyclotron, variable energy that came into operation in 1982, which was used to produce F18-FDG and Iodine 123 up to 1998. The second, a Cyclone 30 cyclotron, 30 MeV, commenced operation in 1998 for certification purpose, and due to increase demand for radiopharmaceuticals in Brazil, started F18-FDG production in 1999. Cyclotron Laboratory will be a reference Research and Developing Center in our country and will help the Brazilian and Latin-American community. It is necessary to have an adequate database to allow regular follow up and analysis of the individual dose distributions for each group involved in the cyclotron activities. These databases are also important means to assess the effectiveness of efforts in order to maintain doses ALARA and reduce inequalities. The official individual occupational dosimetry is provided by certified Laboratory of Thermoluminescent Dosimetry at IPEN-CNEN/SP. This paper describes the occupational doses distribution in Laboratory of Cyclotrons at IPEN-CNEN/SP from January, 1998 to July, 2000 and propose improvements for the future. (author)

  7. Knowledge based operation assist system for JAERI AVF cyclotron

    International Nuclear Information System (INIS)

    Agematsu, T.; Okumura, S.; Yokota, W.; Arakawa, K.; Murakami, T.; Okamura, T.

    1992-01-01

    We have developed two operation assist systems for easy and rapid operation of the JAERI AVF cyclotron. One is a knowledge based expert system guiding the sequence of parameter adjustment to inexperienced cyclotron operators. The other is a real-time simulation of the beam trajectories which are calculated from actual operating parameters. It graphically indicates feasible setting range of parameters that satisfies the acceptance of the cyclotron. These systems provide a human interface to adjust the parameters of the cyclotron. (author)

  8. Commissioning of cryogen delivery system for superconducting cyclotron magnet

    International Nuclear Information System (INIS)

    Pal, G.; Nandi, C.; Bhattacharyya, T.K.; Chaudhuri, J.; Bhandari, R.K.

    2005-01-01

    A K-500 superconducting cyclotron is being constructed at VECC Kolkata. The cryogen delivery system distributes liquid helium and liquid nitrogen to the superconducting cyclotron. Liquid helium is required to cool the cyclotron magnet and cryopanels. Liquid nitrogen is used to reduce the capacity of the helium liquefier. This paper describes the system, the current status and the commissioning experiences of cryogen delivery system for cyclotron magnet. (author)

  9. Developing a national role description for medical directors in long-term care: survey-based approach.

    Science.gov (United States)

    Rahim-Jamal, Sherin; Quail, Patrick; Bhaloo, Tajudaullah

    2010-01-01

    To develop a national role description for medical directors in long-term care (LTC) based on role functions drawn from the literature and the LTC industry. A questionnaire about the role functions identified from the literature was mailed or e-mailed to randomly selected medical directors, directors of care or nursing (DOCs), and administrators in LTC facilities. Long-term care facilities in Canada randomly selected from regional clusters. Medical directors, DOCs, and administrators in LTC facilities; a national advisory group of medical directors from the Long Term Care Medical Directors Association of Canada; and a volunteer group of medical directors. Respondents were asked to indicate, from the list of identified functions, 1) whether medical directors spent any time on each activity; 2) whether medical directors should spend time on each activity; and 3) if medical directors should spend time on an activity, whether the activity was "essential" or "desirable." An overall response rate of 37% was obtained. At least 80% of the respondents from all 3 groups (medical directors, DOCs, and administrators) highlighted 24 functions they deemed to be "essential" or "desirable," which were then included in the role description. In addition, the advisory group expanded the role description to include 5 additional responsibilities from the remaining 18 functions originally identified. A volunteer group of medical directors confirmed the resulting role description. The role description developed as a result of this study brings clarity to the medical director's role in Canadian LTC facilities; the functions outlined are considered important for medical directors to undertake. The role description could be a useful tool in negotiations pertaining to time commitment and expectations of a medical director and fair compensation for services rendered.

  10. ECR ion source for variable energy cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Bose, D K; Taki, G S; Nabhiraj, P Y; Pal, G; Dasgupta, B; Mallik, C; Das, S K; Bandopadhaya, D K; Bhandari, R K [Variable Energy Cyclotron Centre, Calcutta (India)

    1995-09-01

    Some performance characteristics of 6.4 GHz two stage ECR ion source which was under development at this centre is presented. The present ion source will facilitate acceleration of light heavy ions with the existing k=130 variable energy cyclotron. Multiply charged heavy ion (MCHI) beam from the source will also be utilized for atomic physics studies. Oxygen beam has already been used for ion implantation studies. The external injection system under development is nearing completion. Heavy ion beam from cyclotron is expected by end of 1995. (author).

  11. Cyclotron Lines in Accreting Neutron Star Spectra

    Science.gov (United States)

    Wilms, Jörn; Schönherr, Gabriele; Schmid, Julia; Dauser, Thomas; Kreykenbohm, Ingo

    2009-05-01

    Cyclotron lines are formed through transitions of electrons between discrete Landau levels in the accretion columns of accreting neutron stars with strong (1012 G) magnetic fields. We summarize recent results on the formation of the spectral continuum of such systems, describe recent advances in the modeling of the lines based on a modification of the commonly used Monte Carlo approach, and discuss new results on the dependence of the measured cyclotron line energy from the luminosity of transient neutron star systems. Finally, we show that Simbol-X will be ideally suited to build and improve the observational database of accreting and strongly magnetized neutron stars.

  12. Patterns of medical pluralism among adults: results from the 2001 National Health Interview Survey in Taiwan

    Directory of Open Access Journals (Sweden)

    Liao Chien-Chang

    2010-07-01

    Full Text Available Abstract Background Medical pluralism (MP can be defined as the employment of more than one medical system or the use of both conventional and complementary and alternative medicine (CAM for health and illness. A population-based survey and linkage with medical records was conducted to investigate MP amongst the Taiwanese population. Previous research suggests an increasing use of CAM worldwide. Methods We collected demographic data, socioeconomic information, and details about lifestyle and health behaviours from the 2001 Taiwan National Health Interview Survey. The medical records of interviewees were obtained from National Health Insurance claims data with informed consent. In this study, MP was defined as using both Western medicine and traditional Chinese medicine (TCM services in 2001. The odds ratio (OR and 95% confidence interval (CI were estimated for factors associated with adopting MP in univariate and multiple logistic regression. Results Among 12,604 eligible participants, 32.5% adopted MP. Being female (OR = 1.44, 95% CI = 1.30 - 1.61 and young (OR = 1.38, 95% CI = 1.15 - 1.66 were factors associated with adopting MP in the multiple logistic regression. People with healthy lifestyles (OR = 1.35, 95% CI = 1.19 - 1.53 were more likely to adopt MP than those with unhealthy lifestyles. Compared with people who had not used folk therapy within the past month, people who used folk therapy were more likely to adopt MP. The OR of adopting MP was higher in people who lived in highly urbanised areas as compared with those living in areas with a low degree of urbanisation. Living in an area with a high density of TCM physicians (OR = 2.19, 95% CI = 1.69 - 2.84 was the strongest predictor for adopting MP. Conclusion MP is common in Taiwan. Sociodemographic factors, unhealthy lifestyle, use of folk therapy, and living in areas with a high density of TCM physicians are all associated with MP. People who had factors associated with the adoption

  13. A Clinical Decision Support Engine Based on a National Medication Repository for the Detection of Potential Duplicate Medications: Design and Evaluation.

    Science.gov (United States)

    Yang, Cheng-Yi; Lo, Yu-Sheng; Chen, Ray-Jade; Liu, Chien-Tsai

    2018-01-19

    A computerized physician order entry (CPOE) system combined with a clinical decision support system can reduce duplication of medications and thus adverse drug reactions. However, without infrastructure that supports patients' integrated medication history across health care facilities nationwide, duplication of medication can still occur. In Taiwan, the National Health Insurance Administration has implemented a national medication repository and Web-based query system known as the PharmaCloud, which allows physicians to access their patients' medication records prescribed by different health care facilities across Taiwan. This study aimed to develop a scalable, flexible, and thematic design-based clinical decision support (CDS) engine, which integrates a national medication repository to support CPOE systems in the detection of potential duplication of medication across health care facilities, as well as to analyze its impact on clinical encounters. A CDS engine was developed that can download patients' up-to-date medication history from the PharmaCloud and support a CPOE system in the detection of potential duplicate medications. When prescribing a medication order using the CPOE system, a physician receives an alert if there is a potential duplicate medication. To investigate the impact of the CDS engine on clinical encounters in outpatient services, a clinical encounter log was created to collect information about time, prescribed drugs, and physicians' responses to handling the alerts for each encounter. The CDS engine was installed in a teaching affiliate hospital, and the clinical encounter log collected information for 3 months, during which a total of 178,300 prescriptions were prescribed in the outpatient departments. In all, 43,844/178,300 (24.59%) patients signed the PharmaCloud consent form allowing their physicians to access their medication history in the PharmaCloud. The rate of duplicate medication was 5.83% (1843/31,614) of prescriptions. When

  14. Export of radiopharmaceuticals and establishment of export base of cyclotron

    International Nuclear Information System (INIS)

    Jung, Kyungil; Kim, Youngsik

    2006-01-01

    Sam young Unit ech has seized an opportunity to advance into the radiopharmaceuticals market through successful transfer of radiopharmaceuticals manufacturing technology and medical cyclotron, an original technology in nuclear medicine that is the core of less developed areas in nuclear-related fields. The company has continued to push for research development and establishment of market base through industry-academia-research center cooperation with an aim to complement relatively less developed domestic technology and market than in advanced countries, and is making efforts to establish export base in the overseas market based on stabilized supply in the domestic market. As for radiopharmaceuticals, the company is exporting Tc-99m generator to Vietnam, Thailand and the Philippines and preparing itself to export manufacture facilities for Tc-99m generator to Syria and Kazakhstan. In addition, it plans to export 13Mev Cyclotron that has been commercialized after being developed in the domestic market to the U. S. The company plans to grow up to play a pivotal role in the domestic RT area by conducting proactive business activities with an aim to revitalize the domestic market and further domestic original technologies and products in the global market

  15. Evaluation of a national process of reforming curricula in postgraduate medical education

    DEFF Research Database (Denmark)

    Lillevang, Gunver; Bugge, Lasse; Beck, Henning

    2009-01-01

    CONTEXT: A national reform of the postgraduate medical education in Denmark introduced (1) Outcome-based education, (2) The CanMEDS framework of competence related to seven roles of the doctor, and (3) In-training assessment. OBJECTIVES: The purpose of the study was to evaluate the process...... of developing new curricula for 38 specialist training programmes. The research question was: which conditions promote and which conditions impede the process? METHODS: Evaluation of the process was conducted among 76 contact-persons, who were chairing the curriculum development process within the specialties...... and motivation in faculty and support from written guidelines and seminars. Identified impeding factors included insufficient pedagogical support, poor introduction to the task, changing and inconsistent information from authorities, replacement of advisors, and stressful deadlines. CONCLUSIONS: This study...

  16. Thyroid Medication Use and Birth Defects in the National Birth Defects Prevention Study.

    Science.gov (United States)

    Howley, Meredith M; Fisher, Sarah C; Van Zutphen, Alissa R; Waller, Dorothy K; Carmichael, Suzan L; Browne, Marilyn L

    2017-11-01

    Thyroid disorders are common among reproductive-aged women, with hypothyroidism affecting 2 to 3% of pregnancies, and hyperthyroidism affecting an additional 0.1 to 1%. We examined associations between thyroid medications and individual birth defects using data from the National Birth Defects Prevention Study (NBDPS). The NBDPS is a multisite, population-based, case-control study that included pregnancies with estimated delivery dates from 1997 to 2011. We analyzed self-reported thyroid medication use from mothers of 31,409 birth defect cases and 11,536 unaffected controls. Adjusted odds ratios (ORs) and 95% confidence intervals (CIs) were estimated using logistic regression for birth defects with five or more exposed cases, controlling for maternal age, race/ethnicity, and study center. Crude ORs and exact 95% CIs were estimated for defects with 3 to 4 exposed cases. Thyroid hormone was used by 738 (2.3%) case and 237 (2.1%) control mothers, and was associated with anencephaly (OR = 1.68; 95% CI, 1.03-2.73), holoprosencephaly (OR = 2.48; 95% CI, 1.13-5.44), hydrocephaly (1.77; 95% CI, 1.07-2.95) and small intestinal atresia (OR = 1.81; 95% CI, 1.04-3.15). Anti-thyroid medication was used by 34 (0.1%) case and 10 (<0.1%) control mothers, and was associated with aortic valve stenosis (OR = 6.91; 95% CI, 1.21-27.0). While new associations were identified, our findings are relatively consistent with previous NBDPS analyses. Our findings suggest thyroid medication use is not associated with most birth defects studied in the NBDPS, but may be associated with some specific birth defects. These results should not be interpreted to suggest that medications used to treat thyroid disease are teratogens, as the observed associations may reflect effects of the underlying thyroid disease. Birth Defects Research 109:1471-1481, 2017.© 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  17. A line-of-sight electron cyclotron emission receiver for electron cyclotron resonance heating feedback control of tearing modes

    DEFF Research Database (Denmark)

    Oosterbeek, J.W.; Bürger, A.; Westerhof, E.

    2008-01-01

    An electron cyclotron emission (ECE) receiver inside the electron cyclotron resonance heating (ECRH) transmission line has been brought into operation. The ECE is extracted by placing a quartz plate acting as a Fabry-Perot interferometer under an angle inside the electron cyclotron wave (ECW) bea...

  18. Barriers to and determinants of medication adherence among hypertensive patients attended National Health Service Hospital, Sunderland

    Directory of Open Access Journals (Sweden)

    Muhammad Umair Khan

    2014-01-01

    Full Text Available Background: Hypertension is a silent killer, a time bomb in both the developed and developing nations of the world. It is one of the most significant risk factors for cardiovascular morbidity and mortality resulting from target-organ damage to blood vessels in the heart, brain, kidney and eyes. Adherence to long-term therapy for chronic illnesses like hypertension is an important tool to enhance the effectiveness of pharmacotherapy. Objective: The two objectives of this study were to evaluate the extent and reasons of non-adherence in patients attended National Health Service (NHS Hospital, Sunderland. Materials and Methods: The study was conducted for 4 months in the out-patient department of NHS Hospital. A total of 200 patients were selected randomly for this study. Morisky′s Medication Adherence Scale was used to assess the adherence rate and the reason of non-adherence. Data were entered and analyzed using Microsoft Excel 2010. Results: The overall adherence rate was found to be 79% (n = 158. Adherence rate in females were low was compared with their male counterparts (74.7% vs. 85.7%. The higher rate of adherence was found in age group of 30-40 years (82%, n = 64. The major intentional and non-intentional reason of non-adherence was side-effects and forgetfulness respectively. Conclusion: Overall, more than three-fourth of the hypertensive participants were found to be adherent to their treatment. On the basis of factors associated with non-adherence, it is analyzed that suitable therapy must be designed for patients individually to increase medication adherence and its effectiveness.

  19. Building on TR-24 success. Advanced Cyclotron Systems Inc. launches a new cyclotron model

    International Nuclear Information System (INIS)

    Russell Watt; William Gyles; Alexander Zyuzin

    2015-01-01

    ACSI is designing a new 30 MeV cyclotron based on the TR-24. While minimizing changes from the proven TR-24, including maintaining the same outer dimensions, the energy of the cyclotron will be increased to 30 MeV, which will make it the most compact, non-superconducting, 30 MeV cyclotron design to date. Maximum beam current will match the TR-24 at 1 mA. With the size and footprint of a typical low energy PET cyclotron, this system will offer users a cost effective solution for a diversified facility capable of producing a wide spectrum of PET and SPECT radioisotopes for research and commercial distribution. (author)

  20. Concepts and strategies to establish a cyclotron/PET center

    International Nuclear Information System (INIS)

    Hernan Vera Ruiz; D, Ph.

    2004-01-01

    Cyclotron accelerators are prolific sources of charged particle for the production of radionuclides and have become an essential tool in the practice of modern nuclear medicine by providing reliably radiotracers for SPECT and PET studies. In a recent survey conducted by the IAEA in 2001 (1) , the growth in the number of cyclotron facilities installed in laboratories and hospitals in developed as well as developing nations was put into evidence This trend, which started in the late 70's, continues up to the present time, and all indications are that it will continue in the next future. The reasons for this growth are several, amongst them it can be mentioned the fact that the technology involved has became more user or 'hospital friendly', third party reimbursement for several of clinical studies based on F-18 PET radiopharmaceuticals at least in some of the advanced countries starting with F-18FDG in 1998, and above all, the clear, irrefutable and demonstrable Conclusion of the positive cost/benefit outcomes of PET studies in the field of oncology and to a lesser degree, thus far, for cardiology and neurology. It is however recognized that the overall financial cost of the technology, which comprises the premises to house the facility, the cyclotron accelerator, the corresponding radiochemistry and quality control equipment and the PET camera can nevertheless be an expensive proposition that requires careful advance planning. This fact is even more relevant when the facility is planed for installation in a developing country which frequently, in addition to having a lack of sufficient financial resources, do have shortages of qualify human resources for advance planning and later, to run efficiently the facility. Several are the steps that needs consideration when planning a cyclotron facility, the most critical ones are a careful definition of the mission and scope of the facility including the utilization programme of the facility as a whole, followed by a

  1. Selective dissemination of health information: Bulletins of the National Medical Library of Cuba

    Directory of Open Access Journals (Sweden)

    Sonia Santana Arroyo

    2016-10-01

    Full Text Available The National Medical Library of Cuba (BMN has the mission to ensure the provision of scientific and technology information to the community of professionals that make up the healthcare sector in the country, primarily the Ministry of Public Health, identified as prioritized user of BMN, in order to elevate the quality of care, research, management and teaching, as well as to encourage the finding of new solutions that enable to face health problems in Cuba and in the world. This article aims to describe the making process of the bulletins: Bibliomed, Bibliomed Supplemento, BiblioDir and Factográfico de Salud, which are offered by specialists from Selective Dissemination of Information Service that resides in the BMN area of Customer Service, in order to support the decision making of health managers of Cuba Ministry of Public Health. For this purpose, the paper details scope, content, sections, team responsibility, procedures for preparing and processing the bulletins. Most used sources of information and skills of staff are also presented. Such Informative scientific work strengthen BMN as a paradigm of the cuban medical libraries network, transforming the pattern of a traditional library into a modern library, characterized by an effective knowledge management and development processes in virtual environments.

  2. REGULATION OF AUSTRALIAN MEDICAL PROFESSIONALS AND NATIONAL SECURITY: LESSONS FROM THREE CASE STUDIES.

    Science.gov (United States)

    Faunce, Thomas; McKenna, Michael; Rayner, Johanna; Hawes, Jazmin

    2016-03-01

    In recent times, Australia's national security concerns have had controversial impacts on regulation of Australian medical practitioners in areas related to immigration detention. This column explores three recent case studies relevant to this issue. The first involves the enactment of the Australian Border Force Act 2015 (Cth), which has a significant impact on the regulation of medical professionals who work with people in immigration detention. The second involves the decision of the High Court of Australia in Plaintiff M68/2015 v Minister for Immigration and Border Protection [2016] HCA 1 that an amendment to Australian federal legislation justified sending children back to immigration detention centres in Papua New Guinea and Nauru. This legislation was previously heavily criticised by the Australian Human Rights Commissioner. The third concerns the deregistration of Tareq Kamleh, an Australian doctor of German-Palestinian heritage who came to public attention on ANZAC Day 2015 with his appearance online in a propaganda video for the Islamic State terrorist organisation al-Dawla al-Islamyia fil Iraq wa'al Sham, also known as Islamic State of Iraq and Syria (ISIS) or Daesh. Australia's professional regulatory system should presumptively respect professional virtues, such as loyalty to the relief of individual patient suffering, when dealing with doctors (whether in Australia or ISIS-occupied Syria) working under regimes whose principles appear inconsistent with those of ethics and human rights.

  3. [End-of-life in specialized medical pediatrics department: A French national survey].

    Science.gov (United States)

    Ravanello, Alice; Desguerre, Isabelle; Frache, Sandra; Hubert, Philippe; Orbach, Daniel; Aubry, Régis

    2017-03-01

    In France, most of children die in the hospital. This national survey aimed to achieve better understanding of end-of life care in specialized medical pediatrics departments for children facing the end-of-life, identify the available resources, put forward the difficulties encountered by professionals and describe end-of-life paths of children who died in these departments. This study is based on a nationwide survey conducted among all existing specialized medical pediatrics departments (onco-haematology, neurology, reanimation) in France in 2015. Among 94 specialized medical pediatrics departments in France, 53 participated in our survey (response rate=56%). At the time of the survey, 13% of inpatients were facing the end-of-life. Regarding training, 13% of departments did not have personnel trained in palliative care and 21% did not set up any professional support. However, when taking care of a child's end of life in 2014, 77% of these departments solicited a regional resource team of pediatric palliative care. This survey helps describe 225 end-of-life paths of children decease of a terminal illness in the specialized pediatrics departments. Seventy-two percent suffered from refractory symptoms before their death, 64% were concerned by a terminal sedation and 75% by a limitation of life-sustaining treatment decision. End-of-life care is a reality for specialized pediatrics departments. The frequency of major and refractory symptoms often requires the completion of sedation. The resources of service are acceptable but some deficiencies have been noted especially concerning training and support for caregivers, adaptation of premises or family support. Copyright © 2017. Published by Elsevier SAS.

  4. Bullying in the American Graduate Medical Education System: A National Cross-Sectional Survey

    Science.gov (United States)

    2016-01-01

    Objectives To deliver an estimate of bullying among residents and fellows in the United States graduate medical education system and to explore its prevalence within unique subgroups. Design/Setting/Participants A national cross-sectional survey from a sample of residents and fellows who completed an online bullying survey conducted in June 2015. The survey was distributed using a chain sampling method that relied on electronic referrals from 4,055 training programs, with 1,791 residents and fellows completing the survey in its entirety. Survey respondents completed basic demographic and programmatic information plus four general bullying and 20 specific bullying behavior questions. Between-group differences were compared for demographic and programmatic stratifications. Main Outcomes/Measures Self-reported subjected to workplace bullying from peers, attendings, nurses, ancillary staff, or patients in the past 12 months. Results Almost half of the respondents (48%) reported being subjected to bullying although both those subjected and not subjected reported experiencing ≥ 1 bullying behaviors (95% and 39% respectively). Attendings (29%) and nurses (27%) were the most frequently identified source of bullying, followed by patients, peers, consultants and staff. Attempts to belittle and undermine work and unjustified criticism and monitoring of work were the most frequently reported bullying behaviors (44% each), followed by destructive innuendo and sarcasm (37%) and attempts to humiliate (32%). Specific bullying behaviors were more frequently reported by female, non-white, shorter than bullying in the United States graduate medical education programs. Including specific questions on bullying in the Accreditation Council for Graduate Medical Education annual resident/fellow survey, implementation of anti-bullying policies, and a multidisciplinary approach engaging all stakeholders may be of great value to eliminate these pervasive behaviors in the field of

  5. Bullying in the American Graduate Medical Education System: A National Cross-Sectional Survey.

    Directory of Open Access Journals (Sweden)

    Amar R Chadaga

    Full Text Available To deliver an estimate of bullying among residents and fellows in the United States graduate medical education system and to explore its prevalence within unique subgroups.A national cross-sectional survey from a sample of residents and fellows who completed an online bullying survey conducted in June 2015. The survey was distributed using a chain sampling method that relied on electronic referrals from 4,055 training programs, with 1,791 residents and fellows completing the survey in its entirety. Survey respondents completed basic demographic and programmatic information plus four general bullying and 20 specific bullying behavior questions. Between-group differences were compared for demographic and programmatic stratifications.Self-reported subjected to workplace bullying from peers, attendings, nurses, ancillary staff, or patients in the past 12 months.Almost half of the respondents (48% reported being subjected to bullying although both those subjected and not subjected reported experiencing ≥ 1 bullying behaviors (95% and 39% respectively. Attendings (29% and nurses (27% were the most frequently identified source of bullying, followed by patients, peers, consultants and staff. Attempts to belittle and undermine work and unjustified criticism and monitoring of work were the most frequently reported bullying behaviors (44% each, followed by destructive innuendo and sarcasm (37% and attempts to humiliate (32%. Specific bullying behaviors were more frequently reported by female, non-white, shorter than < 5'8 and BMI ≥ 25 individuals.Many trainees report experiencing bullying in the United States graduate medical education programs. Including specific questions on bullying in the Accreditation Council for Graduate Medical Education annual resident/fellow survey, implementation of anti-bullying policies, and a multidisciplinary approach engaging all stakeholders may be of great value to eliminate these pervasive behaviors in the field of

  6. Tokamak startup with electron cyclotron heating

    International Nuclear Information System (INIS)

    Holly, D.J.; Prager, S.C.; Shepard, D.A.; Sprott, J.C.

    1980-04-01

    Experiments are described in which the startup voltage in a tokamak is reduced by approx. 60% by the use of a modest amount of electron cyclotron resonance heating power for preionization. A 50% reduction in volt-second requirement and impurity reflux are also observed

  7. Passive cyclotron current drive for fusion plasmas

    International Nuclear Information System (INIS)

    Kernbichler, W.

    1995-01-01

    The creation of toroidal current using cyclotron radiation in a passive way is, together with the well known bootstrap current, an interesting method for stationary current drive in high-temperature fusion reactors. Here, instead of externally applied RF-waves, fish-scale like structures at the first wall help to create enough asymmetry in the self generated cyclotron radiation intensity to drive a current within the plasma. The problem of computing passive cyclotron current drive consists of actually two linked problems, which are the computation of the electron equilibrium under the presence of self-generated radiation, and the computation of the photon equilibrium in a bounded system with a distorted electron distribution. This system of integro-differential equations cannot be solved directly in an efficient way. Therefore a linearization procedure was developed to decouple both sets of equations, finally linked through a generalized local current drive efficiency. The problem of the exact accounting for the wall profile effects was reduced to the solution of a Fredholm-type integral equation of the 2 nd -kind. Based on all this an extensive computer code was developed to compute the passively driven current as well as radiation losses, radiation transport and overall efficiencies. The results therefrom give an interesting and very detailed insight into the problems related to passive cyclotron current drive

  8. Ion-cyclotron instability in magnetic mirrors

    International Nuclear Information System (INIS)

    Pearlstein, L.D.

    1987-01-01

    This report reviews the role of ion-cyclotron frequency instability in magnetic mirrors. The modes discussed here are loss-cone or anisotropy driven. The discussion includes quasilinear theory, explosive instabilities of 3-wave interaction and non-linear Landau damping, and saturation due to non-linear orbits

  9. The Data Cyclotron query processing scheme

    NARCIS (Netherlands)

    Goncalves, R.; Kersten, M.

    2011-01-01

    A grand challenge of distributed query processing is to devise a self-organizing architecture which exploits all hardware resources optimally to manage the database hot set, minimize query response time, and maximize throughput without single point global coordination. The Data Cyclotron

  10. The Data Cyclotron query processing scheme.

    NARCIS (Netherlands)

    R.A. Goncalves (Romulo); M.L. Kersten (Martin)

    2011-01-01

    htmlabstractA grand challenge of distributed query processing is to devise a self-organizing architecture which exploits all hardware resources optimally to manage the database hot set, minimize query response time, and maximize throughput without single point global coordination. The Data Cyclotron

  11. Cyclotron-based neutron source for BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K. [Sumitomo Heavy Industries, Ltd (Japan); Tanaka, H.; Sakurai, Y.; Maruhashi, A. [Kyoto University Research Reactor Institute (Japan)

    2013-04-19

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation and treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8 Multiplication-Sign 109 neutrons/cm{sup 2}/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with {sup 10}B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  12. <600> MeV synchro-cyclotron

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    One of the 14 pancakes of the new magnet coils for the 600 MeV synchro-cyclotron which were wound and coated with epoxy resin on the CERN site. These new coils will replace the present ones which have been in use for more than 14 years but are now showing signs of deteriorations.

  13. Helical axial injection concept for cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, E.D.

    1981-01-01

    A concept for an external beam injection system using a helical beam path centered on the cyclotron axis is described. This system could be used to couple two accelerator stages, with or without intermediate stripping, in cases where conventional axial injection or radial injection are not practical.

  14. Helical axial injection concept for cyclotrons

    International Nuclear Information System (INIS)

    Hudson, E.D.

    1981-01-01

    A concept for an external beam injection system using a helical beam path centered on the cyclotron axis is described. This system could be used to couple two accelerator stages, with or without intermediate stripping, in cases where conventional axial injection or radial injection are not practical

  15. A visual assistance environment for cyclotron operation

    International Nuclear Information System (INIS)

    Okamura, Tetsuya; Murakami, Tohru; Agematsu, Takashi; Okumura, Susumu; Arakawa, Kazuo.

    1993-01-01

    A computer-based operation system for a cyclotron which assists inexperienced operators has been developed. Cyclotron start-up operations require dozens of adjustable parameters to be finely tuned to maximize extracted beam current. The human interfaces of the system provide a visual environment designed to enhance beam parameter adjustments. First, the mental model of operators is analyzed. It is supposed to be composed of five partial mental models: beam behavior model, feasible setting regions model, parameter sensitivity model, parameter mutual relation model, and status map model. Next, based on these models, three visual interfaces are developed, i.e., (1) Beam trajectory is rapidly calculated and graphically displayed whenever the operators change the cyclotron parameters. (2) Feasible setting regions (FSR) of the parameters that satisfy the cyclotron's beam acceptance criteria are indicated. (3) Search traces, being a historical visual map of beam current values, are superimposed on the FSRs. Finally, to evaluate system effectiveness, the search time required to reach maximum beam current conditions was measured. In addition, system operability was evaluated using written questionnaires. Results of the experiment showed that the search time to reach specific beam conditions was reduced by approximately 65% using these interfaces. The written questionnaires survey showed the operators highly evaluate system operability. (author)

  16. Microwave power coupling with electron cyclotron resonance ...

    Indian Academy of Sciences (India)

    600 W microwave power with an average electron density of ∼ 6 × 1011 cm. −3 ... the angular frequency of the cyclotron motion, e is the electron charge, m is the mass of .... is also suitable for ECR plasma-based applications like high-quality ...

  17. Electron cyclotron emission from thermal plasmas

    International Nuclear Information System (INIS)

    Fidone, I.; Granata, G.

    1978-02-01

    Electron cyclotron radiation from a warm inhomogeneous plasma is investigated. A direct calculation of the emissive power of a plasma slab is performed using Rytov's method and the result is compared with the solution of the transfer equation. It is found that, for arbitrary directions of emission, the two results differ, which reflects the fact that Kirchhoff's law is not generally obeyed

  18. Electron cyclotron heating and associated parallel cooling

    International Nuclear Information System (INIS)

    Rapozo, C. da C.; Assis, A.S. de; Busnardo Neto, J.

    1990-01-01

    It has been experimentally observed that during the electron-cyclotron heating the electron longitudinal temperature drops as the perpendicular temperature increases. The experiment was carried in a linear mirror machine with a low density (10 10 cm -3 ) weakly ionized (< 1.0 %) plasma. (Author)

  19. On Resonant Heating Below the Cyclotron Frequency

    International Nuclear Information System (INIS)

    Chen, Liu; Lin, Zhihong; White, R.

    2001-01-01

    Resonant heating of particles by an electrostatic wave propagating perpendicular to a confining uniform magnetic field is examined. It is shown that, with a sufficiently large wave amplitude, significant perpendicular stochastic heating can be obtained with wave frequency at a fraction of the cyclotron frequency

  20. Electron-cyclotron-resonance ion sources (review)

    International Nuclear Information System (INIS)

    Golovanivskii, K.S.; Dougar-Jabon, V.D.

    1992-01-01

    The physical principles are described and a brief survey of the present state is given of ion sources based on electron-cyclotron heating of plasma in a mirror trap. The characteristics of ECR sources of positive and negative ions used chiefly in accelerator technology are presented. 20 refs., 10 figs., 3 tabs

  1. Currents driven by electron cyclotron waves

    International Nuclear Information System (INIS)

    Karney, C.F.F.; Fisch, N.J.

    1981-07-01

    Certain aspects of the generation of steady-state currents by electron cyclotron waves are explored. A numerical solution of the Fokker-Planck equation is used to verify the theory of Fisch and Boozer and to extend their results into the nonlinear regime. Relativistic effects on the current generated are discussed. Applications to steady-state tokamak reactors are considered

  2. Tokamak startup with electron cyclotron heating

    Energy Technology Data Exchange (ETDEWEB)

    Holly, D J; Prager, S C; Shepard, D A; Sprott, J C

    1980-04-01

    Experiments are described in which the startup voltage in a tokamak is reduced by approx. 60% by the use of a modest amount of electron cyclotron resonance heating power for preionization. A 50% reduction in volt-second requirement and impurity reflux are also observed.

  3. National All Schedules Prescription Electronic Reporting Act (NASPER): balancing substance abuse and medical necessity.

    Science.gov (United States)

    Manchikanti, Laxmaiah; Brown, Keith R; Singh, Vijay

    2002-07-01

    The National All Schedules Prescription Electronic Reporting Act, or NASPER, is a bill proposed by the American Society of Interventional Pain Physicians to provide and improve patient access with quality care, and protect patients and physicians from deleterious effects of controlled substance misuse, abuse and trafficking. Controlled prescription drugs, including narcotic analgesics, anxiolytics, anti-depressants, stimulants, and sedative-hypnotics play a significant and legitimate role in interventional pain management practices in managing chronic pain and related disorders. Based on the 1997 household survey on drug abuse it is estimated that 76.9 million Americans had used an illicit drug at least once in their life. In 1997, 4.2 million people used analgesics, 2.1 million used tranquillizers, and an additional 2.3 million people used various other drugs, including sedatives, tranquillizers, etc. The non-medical use of prescription drugs exceeds that of all illicit substances except for marijuana and hashish. The report on epidemiology trends in drug abuse, based on community epidemiology work group analysis showed continued increase of abuse of prescription drugs in urban, suburban, and rural areas. The most commonly abused drugs include oxycodone, hydrocodone, hydromorphone, morphine, codeine, clonazepam, alprazolam, lorazepam, diazepam and carisoprodol. The diversion of prescription controlled substances to illicit channels is a public health and safety issue. This review describes the role of controlled substances in chronic pain management, prevalence and economic impact of controlled substance abuse, prescription accountability, effectiveness of prescription monitoring programs, and rationale for national controlled substance electronic reporting system.

  4. Assessment of COPD-related outcomes via a national electronic medical record database.

    Science.gov (United States)

    Asche, Carl; Said, Quayyim; Joish, Vijay; Hall, Charles Oaxaca; Brixner, Diana

    2008-01-01

    The technology and sophistication of healthcare utilization databases have expanded over the last decade to include results of lab tests, vital signs, and other clinical information. This review provides an assessment of the methodological and analytical challenges of conducting chronic obstructive pulmonary disease (COPD) outcomes research in a national electronic medical records (EMR) dataset and its potential application towards the assessment of national health policy issues, as well as a description of the challenges or limitations. An EMR database and its application to measuring outcomes for COPD are described. The ability to measure adherence to the COPD evidence-based practice guidelines, generated by the NIH and HEDIS quality indicators, in this database was examined. Case studies, before and after their publication, were used to assess the adherence to guidelines and gauge the conformity to quality indicators. EMR was the only source of information for pulmonary function tests, but low frequency in ordering by primary care was an issue. The EMR data can be used to explore impact of variation in healthcare provision on clinical outcomes. The EMR database permits access to specific lab data and biometric information. The richness and depth of information on "real world" use of health services for large population-based analytical studies at relatively low cost render such databases an attractive resource for outcomes research. Various sources of information exist to perform outcomes research. It is important to understand the desired endpoints of such research and choose the appropriate database source.

  5. Health research priorities in medical thesis at National University of Piura, 2010-2014

    Directory of Open Access Journals (Sweden)

    Nelson Purizaca-Rosillo

    2016-02-01

    Full Text Available OBJETIVES To determine the frequency of thesis to obtain the medical degree at the NationalUniversity of Piura (UNP whose aim was framed within the Peru's nationaland/or Piura's regionalHRP from 201Oto 2014. MATERIAL AND METHODS A cross-sectionalstudy was conducted.All thesis to obtain the medicaldegree registered at the library of the UNP and the specialized library of the human medicine faculty from 2010 to 2014 were included.According the aim of the thesis,it was determinedif it was related toa nationalor regionalHRP.We searched through Google Scholar if the thesis that met witha HRP hadbeen published in a scientific joumal. RESULTS 150 thesis were found in the study period. Only 15 (10% thesis hadas the main objective a nationalHRP and 1 (0.6% a regionalHRP.Besides,none of the thesis had been published. CONCLUSIONS Thereis a low frequency of medicalthesis that were framed within a nationaland/or regionalHRP.

  6. National Characteristics of Emergency Medical Services Responses for Older Adults in the United States.

    Science.gov (United States)

    Duong, Hieu V; Herrera, Lauren Nicholas; Moore, Justin Xavier; Donnelly, John; Jacobson, Karen E; Carlson, Jestin N; Mann, N Clay; Wang, Henry E

    2018-01-01

    Older adults, those aged 65 and older, frequently require emergency care. However, only limited national data describe the Emergency Medical Services (EMS) care provided to older adults. We sought to determine the characteristics of EMS care provided to older adults in the United States. We used data from the 2014 National Emergency Medical Services Information System (NEMSIS), encompassing EMS response data from 46 States and territories. We excluded EMS responses for children older adults as age ≥65 years. We compared patient demographics (age, sex, race, primary payer), response characteristics (dispatch time, location type, time intervals), and clinical course (clinical impression, injury, procedures, medications) between older and younger adult EMS emergency 9-1-1 responses. During the study period there were 20,212,245 EMS emergency responses. Among the 16,116,219 adult EMS responses, there were 6,569,064 (40.76%) older and 9,547,155 (59.24%) younger adults. Older EMS patients were more likely to be white and the EMS incident to be located in healthcare facilities (clinic, hospital, nursing home). Compared with younger patients, older EMS patients were more likely to present with syncope (5.68% vs. 3.40%; OR 1.71; CI: 1.71-1.72), cardiac arrest/rhythm disturbance (3.27% vs. 1.69%; OR 1.97; CI: 1.96-1.98), stroke (2.18% vs. 0.74%; OR 2.99; CI: 2.96-3.02) and shock (0.77% vs. 0.38%; OR 2.02; CI: 2.00-2.04). Common EMS interventions performed on older persons included intravenous access (32.02%), 12-lead ECG (14.37%), CPR (0.87%), and intubation (2.00%). The most common EMS drugs administered to older persons included epinephrine, atropine, furosemide, amiodarone, and albuterol or ipratropium. One of every three U.S. EMS emergency responses involves older adults. EMS personnel must be prepared to care for the older patient.

  7. Relative accuracy and availability of an Irish National Database of dispensed medication as a source of medication history information: observational study and retrospective record analysis.

    LENUS (Irish Health Repository)

    Grimes, T

    2013-01-27

    WHAT IS KNOWN AND OBJECTIVE: The medication reconciliation process begins by identifying which medicines a patient used before presentation to hospital. This is time-consuming, labour intensive and may involve interruption of clinicians. We sought to identify the availability and accuracy of data held in a national dispensing database, relative to other sources of medication history information. METHODS: For patients admitted to two acute hospitals in Ireland, a Gold Standard Pre-Admission Medication List (GSPAML) was identified and corroborated with the patient or carer. The GSPAML was compared for accuracy and availability to PAMLs from other sources, including the Health Service Executive Primary Care Reimbursement Scheme (HSE-PCRS) dispensing database. RESULTS: Some 1111 medication were assessed for 97 patients, who were median age 74 years (range 18-92 years), median four co-morbidities (range 1-9), used median 10 medications (range 3-25) and half (52%) were male. The HSE-PCRS PAML was the most accurate source compared to lists provided by the general practitioner, community pharmacist or cited in previous hospital documentation: the list agreed for 74% of the medications the patients actually used, representing complete agreement for all medications in 17% of patients. It was equally contemporaneous to other sources, but was less reliable for male than female patients, those using increasing numbers of medications and those using one or more item that was not reimbursable by the HSE. WHAT IS NEW AND CONCLUSION: The HSE-PCRS database is a relatively accurate, available and contemporaneous source of medication history information and could support acute hospital medication reconciliation.

  8. Cyclotron resonance cooling by strong laser field

    International Nuclear Information System (INIS)

    Tagcuhi, Toshihiro; Mima, Kunioka

    1995-01-01

    Reduction of energy spread of electron beam is very important to increase a total output radiation power in free electron lasers. Although several cooling systems of particle beams such as a stochastic cooling are successfully operated in the accelerator physics, these cooling mechanisms are very slow and they are only applicable to high energy charged particle beams of ring accelerators. We propose here a new concept of laser cooling system by means of cyclotron resonance. Electrons being in cyclotron motion under a strong magnetic field can resonate with circular polarized electromagnetic field, and the resonance take place selectively depending on the velocity of the electrons. If cyclotron frequency of electrons is equal to the frequency of the electromagnetic field, they absorb the electromagnetic field energy strongly, but the other electrons remain unchanged. The absorbed energy will be converted to transverse kinetic energy, and the energy will be dumped into the radiation energy through bremastrahlung. To build a cooling system, we must use two laser beams, where one of them is counter-propagating and the other is co-propagating with electron beam. When the frequency of the counter-propagating laser is tuned with the cyclotron frequency of fast electrons and the co-propagating laser is tuned with the cyclotron frequency of slow electrons, the energy of two groups will approach and the cooling will be achieved. We solve relativistic motions of electrons with relativistic radiation dumping force, and estimate the cooling rate of this mechanism. We will report optimum parameters for the electron beam cooling system for free electron lasers

  9. Use of simulation-based medical training in Swiss pediatric hospitals: a national survey.

    Science.gov (United States)

    Stocker, Martin; Laine, Kathryn; Ulmer, Francis

    2017-06-17

    Simulation-based medical training (SBMT) is a powerful tool for continuing medical education. In contrast to the Anglo-Saxon medical education community, up until recently, SBMT was scarce in continental Europe's pediatric health care education: In 2009, only 3 Swiss pediatric health care institutions used SBMT. The Swiss catalogue of objectives in Pediatrics does not acknowledge SBMT. The aim of this survey is to describe and analyze the current state of SBMT in Swiss pediatric hospitals and health care departments. A survey was carried out with medical education representatives of every institution. SBMT was defined as any kind of training with a mannequin excluding national and/or international standardized courses. The survey reference day was May 31st 2015. Thirty Swiss pediatric hospitals and health care departments answered our survey (response rate 96.8%) with 66.6% (20 out of 30) offering SBMT. Four of the 20 hospitals offering SMBT had two independently operating training simulation units, resulting in 24 educational units as the basis for our SBMT analysis. More than 90% of the educational units offering SBMT (22 out of 24 units) were conducting in-situ training and 62.5% (15 out of 24) were using high-technology mannequins. Technical skills, communication and leadership ranked among the top training priorities. All institutions catered to inter-professional participants. The vast majority conducted training that was neither embedded within a larger educational curriculum (19 out of 24: 79.2%) nor evaluated (16 out of 24: 66.6%) by its participants. Only 5 institutions (20.8%) extended their training to at least two thirds of their hospital staff. Two thirds of the Swiss pediatric hospitals and health care departments are offering SBMT. Swiss pediatric SBMT is inter-professional, mainly in-situ based, covering technical as well as non-technical skills, and often employing high-technology mannequins. The absence of a systematic approach and reaching only

  10. Irish general practitioner attitudes toward decriminalisation and medical use of cannabis: results from a national survey.

    Science.gov (United States)

    Crowley, Des; Collins, Claire; Delargy, Ide; Laird, Eamon; Van Hout, Marie Claire

    2017-01-13

    Governmental debate in Ireland on the de facto decriminalisation of cannabis and legalisation for medical use is ongoing. A cannabis-based medicinal product (Sativex®) has recently been granted market authorisation in Ireland. This unique study aimed to investigate Irish general practitioner (GP) attitudes toward decriminalisation of cannabis and assess levels of support for use of cannabis for therapeutic purposes (CTP). General practitioners in the Irish College of General Practitioner (ICGP) database were invited to complete an online survey. Anonymous data yielded descriptive statistics (frequencies, percentages) to summarise participant demographic information and agreement with attitudinal statements. Chi-square tests and multi-nominal logistic regression were included. The response rate was 15% (n = 565) which is similar to other Irish national GP attitudinal surveys. Over half of Irish GPs did not support the decriminalisation of cannabis (56.8%). In terms of gender, a significantly higher proportion of males compared with females (40.6 vs. 15%; p cannabis should be decriminalised (54.1 vs. 31.5%; p = 0.021). Over 80% of both genders supported the view that cannabis use has a significant effect on patients' mental health and increases the risk of schizophrenia (77.3%). Over half of Irish GPs supported the legalisation of cannabis for medical use (58.6%). A higher percentage of those who were level 1-trained (trained in addiction treatment but not to an advanced level) agreed/strongly agreed cannabis should be legalised for medical use (p = 0.003). Over 60% agreed that cannabis can have a role in palliative care, pain management and treatment of multiple sclerosis (MS). In the regression response predicator analysis, females were 66.2% less likely to agree that cannabis should be decriminalised, 42.5% less likely to agree that cannabis should be legalised for medical use and 59.8 and 37.6% less likely to agree that cannabis has a role in

  11. ROKCY-12 (KCCH PET-dedicated cyclotron): main features and improvements

    International Nuclear Information System (INIS)

    Chai, J. S.; Kim, Y. S.; Yang, Y. T.; Jung, I. S.; Hong, S. S.; Lee, M. Y.; Jang, H. S.; Kim, J. H.

    2002-01-01

    satisfying the needs and expectations of employees, suppliers, owners, and the nation's society in addition to customers. These criteria make the U.S., Europe, Japan, and other advanced countries elevate the concept of product quality to new heights of importance. Management must strengthen their company's competitiveness by developing and producing creative products that meet the needs of today's and tomorrow's customers. It is now time for cyclotron application team to launch an industry-wide commitment to quality that will propel products and services to the top of the world market

  12. Assessing Advanced Airway Management Performance in a National Cohort of Emergency Medical Services Agencies.

    Science.gov (United States)

    Wang, Henry E; Donnelly, John P; Barton, Dustin; Jarvis, Jeffrey L

    2018-05-01

    Although often the focus of quality improvement efforts, emergency medical services (EMS) advanced airway management performance has few national comparisons, nor are there many assessments with benchmarks accounting for differences in agency volume or patient mix. We seek to assess variations in advanced airway management and conventional intubation performance in a national cohort of EMS agencies. We used EMS data from ESO Solutions, a national EMS electronic health record system. We identified EMS emergency responses with attempted advanced airway management (conventional intubation, rapid sequence intubation, sedation-assisted intubation, supraglottic airway insertion, and cricothyroidotomy). We also separately examined cases with initial conventional intubation. We determined EMS agency risk-standardized advanced airway management and initial conventional intubation success rates by using mixed-effects regression models, fitting agency as a random intercept, adjusting for patient age, sex, race, cardiac arrest, or trauma status, and use of rapid sequence or sedation-assisted intubation, and accounting for reliability variations from EMS agency airway volume. We assessed changes in agency advanced airway management and initial conventional intubation performance rank after risk and reliability adjustment. We also identified high and low performers (reliability-adjusted and risk-standardized success confidence intervals falling outside the mean). During 2011 to 2015, 550 EMS agencies performed 57,209 advanced airway management procedures. Among 401 EMS agencies with greater than or equal to 10 advanced airway management procedures, there were a total of 56,636 procedures. Median reliability-adjusted and risk-standardized EMS agency advanced airway management success was 92.9% (interquartile range 90.1% to 94.8%; minimum 58.2%; maximum 99.0%). There were 56 advanced airway management low-performing and 38 high-performing EMS agencies. Among 342 agencies with

  13. Possibilities of 140Nd production by the VINCY cyclotron

    International Nuclear Information System (INIS)

    Comor, J.J.; Dakovic, M.

    2000-01-01

    Application of positron emission tomography (PET) in modern medical diagnosis relies on the application of short lived radionuclides 11 C, 13 N, 15 O and 18 F, presuming their production in the close vicinity of the PET camera. Application of long-lived positron emitters would enable the regional distribution of PET radiopharmaceuticals, which would significantly lower the price of PET diagnosis, as well as enable its application in fields currently inhibited by the short half-life of available positron emitters. One of the candidates for application in PET is the generator system 140 Nd/ 140 Pr, due to the long half-life of 140 Nd (3,37 days). Theoretical calculations confirm that this radionuclide can be produced with high yields by protons accelerated to energies bellow 30 MeV. Due to its optimal operating parameters, the VINCY Cyclotron could produce enough 140 Nd for its regional distribution to a number of PET centers (author)

  14. Control system specification for a cyclotron and neutron therapy facility

    International Nuclear Information System (INIS)

    Jacky, J.; Risler, R.; Kalet, I.; Wootton, P.; Barke, A.; Brossard, S.; Jackson, R.

    1991-01-01

    It is usually considered an essential element of good practice in engineering to produce a specification for a system before building it. However, it has been found to be quite difficult to produce useful specifications of large software systems. The authors have nearly completed a comprehensive specification for the computer control system of a cyclotron and treatment facility that provides particle beams for cancer treatments with fast neutrons, production of medical isotopes, and physics experiments. They describe the control system as thoroughly as is practical using standard technical English, supplemented by tables, diagrams, and some algebraic equations. This specification comprises over 300 single-spaced pages. A more precise and compact specification might be achieved by making greater use of formal mathematical notations instead of English. They have begun work on a formal specification of the system, using the Z and Petri net notations

  15. Evaluation of {sup 18}F radioactive concentration in exhaust at cyclotron facility at Chosun University

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Cheol Ki; Jang, Han; Lee, Goung Jin [Dept. of Nuclear Engineering, Chsoun University, Gwangju (Korea, Republic of)

    2016-11-15

    the recent prevalence of PET examinations in Korea has led to an increase in the number of cyclotrons. the medical isotope 18F produced in most cyclotron facilities currently operating in Korea is emitted into the environment during the production of [{sup 18}F]FdG, a cancerdiagnosis reagent. the amount of [{sup 18}F]FdG synthesized determines the radioactive concentration of {sup 18}F in the exhaust. at some facilities, this amount temporarily exceeds the emission limit. In this study, we evaluated the {sup 18}F radioactivity concentration in the exhaust from the cyclotron facility at chosun university. the {sup 18}F radioactivity concentration was measured using an air sampler and a hPGe semiconductor detector. the measurements showed that the radioactive concentration of {sup 18}F in the exhaust at the cyclotron facility at Chosun university was the highest during [{sup 18}F]FdG synthesis but remained under the legal limit of 2,000 Bq m{sup -3}.

  16. Development of a low-level RF control system for PET cyclotron CYCIAE-14

    Energy Technology Data Exchange (ETDEWEB)

    Li, Pengzhan, E-mail: lipengzhan@ciae.ac.cn; Yin, Zhiguo; Ji, Bin; Zhang, Tianjue; Zhao, Zhenlu

    2014-01-21

    The project of a 14 MeV PET cyclotron aiming at medical diagnosis and treatment was proposed and started at CIAE in 2010. The low-level RF system is designed to stabilize acceleration voltage and control the resonance of the cavity. Based on the experience of the existing CRM Cyclotron in CIAE, a new start-up sequence is developed and tested. The frequency sweeping is used to activate the RF system. Before the tuner is put into use, a new state called “DDS tuning” is applied to trace the resonance frequency to the designed value. This new option state helps to cover the tuning range, if a large frequency variation occurs because of a thermal cavity deformation. The logic control unit detects the spark, reflection, Pulse/CW state and the frequency of the RF source to perform all kinds of protection and state operations. The test bench and on-line test are carried out to verify the initial design. -- Highlights: • The low-level RF system is designed and verified for PET cyclotron CYCIAE-14. • The frequency sweeping is used to activate the RF system. • A new state called “DDS tuning” is applied to trace the resonance frequency. • This new option state helps to cover the tuning range. • Protection module allows a quick restart after an alarm and improves cyclotron's efficiency.

  17. The use of medication against attention deficit/hyperactivity disorder in Denmark: a drug use study from a national perspective

    DEFF Research Database (Denmark)

    Pottegård, Anton; Bjerregaard, Bine Kjøller; Glintborg, Dorte

    2012-01-01

    Purpose The purpose of the study was to characterize the utilization of medication against attention deficit hyperactivity disorder (ADHD) in Denmark between 1995 and 2011 from a national perspective, by using population-based prescription data. Methods National data on drug use in Denmark between...... and lacking evidence of heavy users. However, the prescriber profile for incident users and the large regional variances raise concerns. It is therefore vital that the use of ADHD drugs is closely monitored....

  18. Cyclotron-produced radioisotopes and their clinical use at the Austin PET Centre

    Energy Technology Data Exchange (ETDEWEB)

    Tochon-Danguy, H.J. [Centre for PET, Melbourne, VIC (Australia). Austin and Repatriation Medical Centre

    1997-12-31

    A Centre for Positron Emission Tomography (PET) has been established within the Department of Nuclear Medicine at the Austin and Repatriation Medical Centre in Melbourne. PET is a non-invasive technique based on the use of biologically relevant compounds labelled with short-lived positron-emitting radionuclides such as carbon-11, nitrogen-13, oxygen-15 and fluorine-18. The basic equipment consists of a medical cyclotron (10 MeV proton and 5 MeV deuteron), six lead-shielded hot cells with associated radiochemistry facilities and a whole body PET scanner. During its first five years of operation, the Melbourne PET Centre, has pursued a strong radiolabelling development program, leading to an ambitious clinical program in neurology, oncology and cardiology. This presentation will describe the basic principles of the PET technique and review the cyclotron-produced radioisotopes and radiopharmaceuticals. Radiolabelling development programs and clinical applications are also addressed. 30 refs., 1 tab., 1 fig.

  19. Cyclotron-produced radioisotopes and their clinical use at the Austin PET Centre

    International Nuclear Information System (INIS)

    Tochon-Danguy, H.J.

    1997-01-01

    A Centre for Positron Emission Tomography (PET) has been established within the Department of Nuclear Medicine at the Austin and Repatriation Medical Centre in Melbourne. PET is a non-invasive technique based on the use of biologically relevant compounds labelled with short-lived positron-emitting radionuclides such as carbon-11, nitrogen-13, oxygen-15 and fluorine-18. The basic equipment consists of a medical cyclotron (10 MeV proton and 5 MeV deuteron), six lead-shielded hot cells with associated radiochemistry facilities and a whole body PET scanner. During its first five years of operation, the Melbourne PET Centre, has pursued a strong radiolabelling development program, leading to an ambitious clinical program in neurology, oncology and cardiology. This presentation will describe the basic principles of the PET technique and review the cyclotron-produced radioisotopes and radiopharmaceuticals. Radiolabelling development programs and clinical applications are also addressed

  20. Ionizing radiation in medical education in the National University of Cuyo

    International Nuclear Information System (INIS)

    Lopez Vernengo, Andrea B.

    2009-01-01

    Medical irradiations constitute the most important contribution to the human exposure to ionizing radiations of artificial origin. The world-wide statistics indicate an increasing tendency in the annual number of these practices based on the development of new techniques of diagnosis by images, the application of new drugs labeled with diverse isotopes and novel advances in cancer treatments. Due to this widespread use, Radiation Protection (RP) has become an excellent subject for scientific societies and regulating organisms. In this sense, most of the European countries have implemented plans of action for the radiological safety of the patient. An example is the guide RP/116 reported by the European Commission in the year 2000, which recommends including a course about RP in the study programs of Schools of Medicine and Dentistry. Consequently, the general purpose of this research project was to critically describe and to analyze the present situation of educational contents referred to the use of ionizing radiations in the Career of Medicine of the National University of Cuyo. The main results show that there is no curricular subject or area of study which includes in its syllabus minimum compulsory contents about RP or basic knowledge about Radiation Physics. In addition, RP and environmental topics related to the use of ionizing radiations in Medicine are not developed according to the 4 recommendations published by specialized International Organisms. Considering that many methods of diagnosis by images use ionizing radiations, it is suggested that that the curriculum of the Medical Career include contents related to this issue. The aim is to incorporate the culture of RP in the formative process of future professionals and, consequently, to reduce the execution of non-justified practices that threaten both individual and environmental health. (authors) [es

  1. Accelerator Production of Isotopes for Medical Use

    Science.gov (United States)

    Lapi, Suzanne

    2014-03-01

    The increase in use of radioisotopes for medical imaging and therapy has led to the development of novel routes of isotope production. For example, the production and purification of longer-lived position emitting radiometals has been explored to allow for nuclear imaging agents based on peptides, antibodies and nanoparticles. These isotopes (64Cu, 89Zr, 86Y) are typically produced via irradiation of solid targets on smaller medical cyclotrons at dedicated facilities. Recently, isotope harvesting from heavy ion accelerator facilities has also been suggested. The Facility for Rare Isotope Beams (FRIB) will be a new national user facility for nuclear science to be completed in 2020. Radioisotopes could be produced by dedicated runs by primary users or may be collected synergistically from the water in cooling-loops for the primary beam dump that cycle the water at flow rates in excess of hundreds of gallons per minute. A liquid water target system for harvesting radioisotopes at the National Superconducting Cyclotron Laboratory (NSCL) was designed and constructed as the initial step in proof-of-principle experiments to harvest useful radioisotopes in this manner. This talk will provide an overview of isotope production using both dedicated machines and harvesting from larger accelerators typically used for nuclear physics. Funding from Department of Energy under DESC0007352 and DESC0006862.

  2. Proceedings [of the] Second National Conference of State Medical Association Representatives on Continuing Medical Education, October 13-15, 1970.

    Science.gov (United States)

    American Medical Association, Chicago, IL.

    The responsibility of organized medicine in the area of continuing education was the focus of this conference. Papers presented at the conference and summaries of workshop discussion groups comprise this document. The papers are: The Purpose of the Conference; Maintenance of Physician Competence; Motivation for Continuing Medical Education; Peer…

  3. Development of a National Consensus for Tactical Emergency Medical Support (TEMS) Training Programs--Operators and Medical Providers.

    Science.gov (United States)

    Schwartz, Richard; Lerner, Brooke; Llwewllyn, Craig; Pennardt, Andre; Wedmore, Ian; Callaway, David; Wightman, John; Casillas, Raymond; Eastman, Alex; Gerold, Kevin; Giebner, Stephen; Davidson, Robert; Kamin, Richard; Piazza, Gina; Bollard, Glenn; Carmona, Phillip; Sonstrom, Ben; Seifarth, William; Nicely, Barbara; Croushorn, John; Carmona, Richard

    2014-01-01

    Tactical teams are at high risk of sustaining injuries. Caring for these casualties in the field involves unique requirements beyond what is provided by traditional civilian emergency medical services (EMS) systems. Despite this need, the training objectives and competencies are not uniformly agreed to or taught. An expert panel was convened that included members from the Departments of Defense, Homeland Security, Justice, and Health and Human Services, as well as federal, state, and local law-enforcement officers who were recruited through requests to stakeholder agencies and open invitations to individuals involved in Tactical Emergency Medical Services (TEMS) or its oversight. Two face-to-face meetings took place. Using a modified Delphi technique, previously published TEMS competencies were reviewed and updated. The original 17 competency domains were modified and the most significant changes were the addition of Tactical Emergency Casualty Care (TECC), Tactical Familiarization, Legal Aspects of TEMS, and Mass Casualty Triage to the competency domains. Additionally, enabling and terminal learning objectives were developed for each competency domain. This project has developed a minimum set of medical competencies and learning objectives for both tactical medical providers and operators. This work should serve as a platform for ensuring minimum knowledge among providers, which will serve enhance team interoperability and improve the health and safety of tactical teams and the public. 2014.

  4. Comparative Effectiveness of Smoking Cessation Medications: A National Prospective Cohort From Taiwan.

    Directory of Open Access Journals (Sweden)

    Po-Yin Chang

    Full Text Available Relative effectiveness of smoking cessation medications-varenicline, bupropion and nicotine replacement therapy (NRT-remains unclear among smokers in real-world settings. Evidence in females and smokers with light/moderate nicotine dependence is particularly insufficient. This study compared the effectiveness of varenicline, bupropion or NRT gum relative to NRT patch, in achieving abstinence among recent quitters.In a national smoking cessation program in Taiwan (2012-2015, a cohort of 11,968 participants received varenicline (n = 5,052, bupropion (n = 823, NRT gum (n = 1944 or NRT patch (n = 4,149. The 7-day, 1-month or 6-month point-prevalence was calculated based on self-reported last smoking event via telephone interview after 6 months. Logistic regression modellings estimated odds ratios (OR and 95% confidence intervals (CI for achieving abstinence using different modalities (NRT patch as referent. Models included age, sex, education, marital status, geographic region, smoke-years, nicotine-dependence level, medical institution, number of clinic visits and medication use duration. Analyses were further stratified by sex and dependence severity.Participants were predominantly male (83% with a mean age of 43.7±12.6 years. Varenicline users were more likely than NRT patch users to achieve abstinence, based on 7-day point-prevalence (OR = 1.30, CI: 1.19-1.44, 1-month point-prevalence (OR = 1.36, CI: 1.24-1.50 or 6-month point-prevalence (OR = 1.30, CI: 1.14-1.47. Compared with NRT patch, varenicline was associated with greater odds of being abstinent in women (OR = 1.29, CI: 1.01-1.65, men (OR = 1.31, CI: 1.18-1.46, those with light/moderate dependence (OR = 1.42, CI: 1.24-1.63 or smokers with severe dependence (OR = 1.19, CI: 1.04-1.37, based on 7-day point-prevalence. Differences in effectiveness were not observed between users of bupropion, NRT gum and NRT patch.In smoking cessation clinics in Taiwan, varenicline users reported higher

  5. SPES: A new cyclotron-based facility for research and applications with high-intensity beams

    Science.gov (United States)

    Maggiore, M.; Campo, D.; Antonini, P.; Lombardi, A.; Manzolaro, M.; Andrighetto, A.; Monetti, A.; Scarpa, D.; Esposito, J.; Silvestrin, L.

    2017-06-01

    In 2016, Laboratori Nazionali di Legnaro (Italy) started the commissioning of a new accelerator facility based on a high-power cyclotron able to deliver proton beams up to 70 MeV of energy and 700 μA current. Such a machine is the core of the Selective Production of Exotic Species (SPES) project whose main goal is to provide exotics beam for nuclear and astrophysics research and to deliver high-intensity proton beams for medical applications and neutrons generator.

  6. The European Federation of Organisations for Medical Physics Policy Statement No. 6.1: Recommended Guidelines on National Registration Schemes for Medical Physicists.

    Science.gov (United States)

    Christofides, Stelios; Isidoro, Jorge; Pesznyak, Csilla; Bumbure, Lada; Cremers, Florian; Schmidt, Werner F O

    2016-01-01

    This EFOMP Policy Statement is an update of Policy Statement No. 6 first published in 1994. The present version takes into account the European Union Parliament and Council Directive 2013/55/EU that amends Directive 2005/36/EU on the recognition of professional qualifications and the European Union Council Directive 2013/59/EURATOM laying down the basic safety standards for protection against the dangers arising from exposure to ionising radiation. The European Commission Radiation Protection Report No. 174, Guidelines on Medical Physics Expert and the EFOMP Policy Statement No. 12.1, Recommendations on Medical Physics Education and Training in Europe 2014, are also taken into consideration. The EFOMP National Member Organisations are encouraged to update their Medical Physics registration schemes where these exist or to develop registration schemes taking into account the present version of this EFOMP Policy Statement (Policy Statement No. 6.1"Recommended Guidelines on National Registration Schemes for Medical Physicists"). Copyright © 2016. Published by Elsevier Ltd.

  7. Production of exotic beams at the LBL 88-Inch Cyclotron by the ISOL method

    International Nuclear Information System (INIS)

    1990-04-01

    The Users of the LBL 88-Inch Cyclotron are preparing a proposal to produce exotic, i.e., radioactive beams. The facility will consist of a high-current 30 MeV cyclotron to generate the radioactive nuclei, an ECR source that can be coupled to different production targets, and the 88-Inch Cyclotron to accelerate the radioactive ions. Thus, the basic concept is that of the double cyclotron system pioneered at Louvain-la-Neuve, although the initial emphasis will be on producing a variety of light proton-rich beams at energies up to 10 MeV/A. At this workshop we wish to outline what is being planned, to invite comments and suggestions, and, especially, to encourage participation. We believe that this facility will be an important step toward establishing the scientific and technical basis for a National High Intensity Facility. This can be achieved through active participation by members of the radioactive beam (RB) community in (1) experiments with high quality radioactive beams of moderate intensity and, (2) R ampersand D on high beam-power targets and highly efficient ion sources. 5 refs., 4 figs

  8. MAAGs (Medical Audit Advisory Groups): the Eli Lilly National Clinical Audit Centre.

    Science.gov (United States)

    Baker, R; Fraser, R

    1993-01-01

    Outlines the framework for promoting audit in general practice, created as one part of the health service reforms. Medical Audit Advisory Groups (MAAGs) were set up in each district with the aim of participation in audit of all general practitioners by April 1992. The activities undertaken have included those recommended by the Department of Health; the most significant of these being the appointment of lay facilitators who are able to assist general practitioners and primary care teams co-operate over efforts to improve the quality of care, and may offer one means of introducing some of the methods of total quality management into general practice. Discusses the problems which remain: audit is not yet sufficiently systematic, interface audit with secondary care is at a very early stage, the ways to involve managers and patients in audit remain to be clarified, and there is little evidence of the consequences of audit in terms of improved care. The Eli Lilly National Clinical Audit Centre has been set up within the Department of General Practice, University of Leicester, in order to address these issues.

  9. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency.

    Science.gov (United States)

    Nagornov, Konstantin O; Kozhinov, Anton N; Tsybin, Yury O

    2017-04-01

    The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω c . In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω c quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω + ), whereas the ω c and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω + quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω c frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω + frequencies can be reduced to negligible levels relative to peaks close to ω c frequencies. Due to reduced errors with which the ω c quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω + frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences. Graphical Abstract ᅟ.

  10. Radiation protection of cyclotron vault with maze in PET Cyclotron Center

    International Nuclear Information System (INIS)

    Fueloep, Marko

    2003-01-01

    The PET Cyclotron center (PCC) is a complex for production, research and application of positron radiopharmaceuticals for PET (Positron Emission Tomography), which was commissioned this year (2004) in Bratislava, Slovak Republic. Positron radionuclides are produced by 18/9 MeV proton/deuteron cyclotron CYCLONE 18/9. Radiation protection of personnel and inhabitants against ionizing radiation in the PCC is solved with regard to the ICRP recommendations and Slovak regulatory system, protection rules and criteria and optimization of radiation protection. In the article comparisons of calculated and measured neutron and gamma dose equivalent rates around the CYCLONE 18/9 and at various points behind the shielding of cyclotron vault with maze are presented. Description of the CYCLONE 18/9 as a source of angular distribution of neutron energy spectra (production of 18 F was considered) was simulated by Monte Carlo code MCNPX. Code MCNP4B was used for shielding calculation of cyclotron vault with maze. Neutron energy spectra behind the shielding were measured by Bonner spectrometer. The values of neutron dose equivalent, which were calculated and measured around the CYCLONE 18/9 and at various points behind the shielding of cyclotron vault with maze, are within the range of factor 2. (authors)

  11. Research and education by SF cyclotron facility

    International Nuclear Information System (INIS)

    1992-04-01

    This report represents the current activities in research and education using the cyclotron facility and related apparatus which are supported by Nuclear Physics Division and this is a continuation of INS-T-466 (1986, December). In this version an iron-free β-ray spectrometer and a cooler-synchrotron (TARN II) are briefly described also in the first chapter. The second chapter explains experimental programs performed in the last 5 years. The third chapter gives the number of publications on researches performed in 1975-1991, and also gives twelve topics obtained from the cyclotron and the β-ray spectrometer in recent 5 years. The last chapter provides the whole list of the works for Doctor and Master theses performed at the facility in the last 10 years. (J.P.N.)

  12. MMS Observations of Harmonic Electromagnetic Cyclotron Waves

    Science.gov (United States)

    Usanova, M.; Ahmadi, N.; Ergun, R.; Trattner, K. J.; Fuselier, S. A.; Torbert, R. B.; Mauk, B.; Le Contel, O.; Giles, B. L.; Russell, C. T.; Burch, J.; Strangeway, R. J.

    2017-12-01

    Harmonically related electromagnetic ion cyclotron waves with the fundamental frequency near the O+ cyclotron frequency were observed by the four MMS spacecraft on May 20, 2016. The wave activity was detected by the spacecraft on their inbound passage through the Earth's morning magnetosphere during generally quiet geomagnetic conditions but enhanced solar wind dynamic pressure. It was also associated with an enhancement of energetic H+ and O+ ions. The waves are seen in both magnetic and electric fields, formed by over ten higher order harmonics, most pronounced in the electric field. The wave activity lasted for about an hour with some wave packets giving rise to short-lived structures extending from Hz to kHz range. These observations are particularly interesting since they suggest cross-frequency coupling between the lower and higher frequency modes. Further work will focus on examining the nature and role of these waves in the energetic particle dynamics from a theoretical perspective.

  13. Neutron radiography with the cyclotron, 3

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi; Fujishiro, Masatoshi; Tsujii, Yukio

    1985-01-01

    Neutron radiography is well recognized as a powerful tool in nondestructive testing, but not widely used yet owing to lack of high intense thermal neutron source convenient for practical use. A new neutron radiograph facility, utilizing a sub-compact cyclotron as neutron source and equipped with vertical and horizontal irradiation ports, is presented in this article. A series of experiment, prior to its construction, was conducted using beams of a variable energy cyclotron at Tohoku University to investigate the characteristics of thermal neutron obtained, from 9 Be (p, n) reaction and thermalized by elastic scattering process. This article describes a computer simulation of neutron moderator to analyze conditions getting maximal thermal neutron flux. Some of practical neutron radiograph examination of aero-space components and museum art objects of classic bronze mirror are also presented together with an attempt realizing real time imaging technique. (author)

  14. Research activities by INS cyclotron facility

    International Nuclear Information System (INIS)

    1992-06-01

    Research activities made by the cyclotron facility and the related apparatuses at Institute for Nuclear Study (INS), University of Tokyo, have been reviewed in terms of the associated scientific publications. This publication list, which is to be read as a continuation of INS-Rep.-608 (October, 1986), includes experimental works on low-energy nuclear physics, accelerator technology, instrumental developments, radiation physics and other applications in interdisciplinary fields. The publications are classified into the following four categories. (A) : Internal reports published in INS. (B) : Publications in international scientific journals on experimental research works done by the cyclotron facility and the related apparatuses at INS. Those made by outside users are also included. (C) : Publications in international scientific journals on experimental low-energy nuclear physics, which have been done by the staff of INS Nuclear Physics Division using facilities outside INS. (D) : Contributions to international conferences. (author)

  15. Matching of ion sources to cyclotron inflectors

    International Nuclear Information System (INIS)

    Baartman, R.

    1988-06-01

    In general, cyclotron inflectors strongly couple the two transverse subspaces. This leads to a growth in emittance projections for a beam with no initial correlation between the two transverse subspaces. Only in the case of the Mueller (hyperboloid) inflector is there no emittance growth. We have made calculations using an optimization routine to match a given beam through the axial injection system. We find that in the limit where all the emittance is due to a beam's axial angular momentum (for example, from an ECR source), matching with no emittance growth is possible even in the case of mirror or spiral inflectors. Moreover, any one of the two transverse emittances circulating in the cyclotron can be made smaller than the source emittance while maintaining the sum of the emittances constant. This is achieved by rotating the matching quadrupoles with respect to the inflector and retuning

  16. Cyclotrons as Drivers for Precision Neutrino Measurements

    International Nuclear Information System (INIS)

    Alonso, J.; Barletta, W. A.; Winslow, L. A.; Shaevitz, M. H.; Spitz, J.; Conrad, J. M.; Toups, M.; Adelmann, A.

    2014-01-01

    As we enter the age of precision measurement in neutrino physics, improved flux sources are required. These must have a well defined flavor content with energies in ranges where backgrounds are low and cross-section knowledge is high. Very few sources of neutrinos can meet these requirements. However, pion/muon and isotope decay-at-rest sources qualify. The ideal drivers for decay-at-rest sources are cyclotron accelerators, which are compact and relatively inexpensive. This paper describes a scheme to produce decay-at-rest sources driven by such cyclotrons, developed within the DAEδALUS program. Examples of the value of the high precision beams for pursuing Beyond Standard Model interactions are reviewed. New results on a combined DAEδALUS—Hyper-K search for CP violation that achieve errors on the mixing matrix parameter of 4° to 12° are presented

  17. Hybrid simulation of electron cyclotron resonance heating

    Energy Technology Data Exchange (ETDEWEB)

    Ropponen, T. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FI-40014 (Finland)], E-mail: tommi.ropponen@phys.jyu.fi; Tarvainen, O. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Suominen, P. [CERN Geneve 23, CH-1211 (Switzerland); Koponen, T.K. [Department of Physics, University of Jyvaeskylae, Nanoscience Center, P.O. Box 35, FI-40014 (Finland); Kalvas, T.; Koivisto, H. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FI-40014 (Finland)

    2008-03-11

    Electron Cyclotron Resonance (ECR) heating is a fundamentally important aspect in understanding the physics of Electron Cyclotron Resonance Ion Sources (ECRIS). Absorption of the radio frequency (RF) microwave power by electron heating in the resonance zone depends on many parameters including frequency and electric field strength of the microwave, magnetic field structure and electron and ion density profiles. ECR absorption has been studied in the past by e.g. modelling electric field behaviour in the resonance zone and its near proximity. This paper introduces a new ECR heating code that implements damping of the microwave power in the vicinity of the resonance zone, utilizes electron density profiles and uses right hand circularly polarized (RHCP) electromagnetic waves to simulate electron heating in ECRIS plasma.

  18. The National Clinical Skills Competition Promotes the Construction of a Comprehensive Training Program for Chinese Medical Students

    Science.gov (United States)

    Yang, Jing; Huang, Si-min; Lu, Chun-ting; Feng, Lie

    2018-01-01

    To explore an efficient training program based on an analysis in organizing seven sessions for the National Clinical Skills Competition in China. Each year, 6-12 excellent medical students of our university are selected as an observation team. Comparisons of the teaching characteristics were performed in this study. An optimal curriculum…

  19. A national stakeholder consensus study of challenges and priorities for clinical learning environments in postgraduate medical education

    NARCIS (Netherlands)

    Kilty, Caroline; Wiese, Anel; Bergin, Colm; Flood, Patrick; Fu, Na; Horgan, Mary; Higgins, Agnes; Maher, Bridget; O’Kane, Grainne; Prihodova, Lucia; Slattery, Dubhfeasa; Stoyanov, Slavi; Bennett, Deirdre

    2018-01-01

    Background: High quality clinical learning environments (CLE) are critical to postgraduate medical education (PGME). The understaffed and overcrowded environments in which many residents work present a significant challenge to learning. The purpose of this study was to develop a national expert

  20. [The Ethics and Deontology division of the French National Council of Medical Doctors, eight years of activity, 1993-2001].

    Science.gov (United States)

    Hoerni, Bernard

    2011-01-01

    The activity of the division of Ethics and deontology of the French National council of medical doctors is analysed by its former president (1993-2001). Among a lot of topics, a new version of the professionnal Code of deontology and patients' information were the main subjects of reflection and action.

  1. Compact superconducting 250 MeV proton cyclotron for the PSI PROSCAN proton therapy project

    International Nuclear Information System (INIS)

    Schillo, M.; Geisler, A.; Hobl, A.; Klein, H.U.; Krischel, D.; Meyer-Reumers, M.; Piel, C.; Blosser, H.; Kim, J.-W.; Marti, F.; Vincent, J.; Brandenburg, S.; Beijers, J.P.M.

    2001-01-01

    A cyclotron for proton therapy has to fulfill many requirements set by the specific operational and safety needs of a medical facility and the medical environment. These are for instance high extraction efficiency, high availability and reliability, simple and robust operation. ACCEL Instruments GmbH has refined the design concept of a medical cyclotron for the PSI PROSCAN project with the objective to use this cyclotron as the standard accelerator in complete proton therapy facilities, which ACCEL intends to market. Starting from the design, we have carried out further detail clarifications, optimizations and adaptations to the needs of PSI. The work was performed in a collaboration between ACCEL, NSCL and KVI in view of the requirements from the PSI PROSCAN project. An overview on the design will be given touching on subjects such as the 3D structural analysis of the coil, detailed magnetic modeling for optimization of the inner region and the spiral, optimization of the RF power, optimization of the cryogenic design based on available cryocoolers instead of a liquefaction plant and Monte Carlo simulations to estimate the heat balance produced by neutrons at 4K components

  2. Electron cyclotron emission from the PLT tokamak

    International Nuclear Information System (INIS)

    Hosea, J.; Arunasalam, V.; Cano, R.

    1977-07-01

    Experimental measurements of electron cyclotron emission from the PLT tokamak plasma reveal that black-body emission occurs at the fundamental frequency. Such emission, not possible by direct thermal excitation of electromagnetic waves, is herein attributed to thermal excitation of electrostatic (Bernstein) waves which then mode convert into electromagnetic waves. The local feature of the electrostatic wave generation permits spatially and time resolved measurements of electron temperature as for the second harmonic emission

  3. Use of maze in cyclotron hoppers

    International Nuclear Information System (INIS)

    Fernandes, Fernando A.; Alves, Juliano S.; Fochesatto, Cintia; Cerioli, Luciane; Borges, Joao Alfredo; Gonzalez, Delfin; Silva, Daniel C.

    2013-01-01

    Introduction: the increasing number of cyclotrons in Brazil due to constitutional amendment 49 /06 that enabled the production of radiopharmaceuticals with a short half - life by private companies. The radionuclides used for PET - CT require production centers near or within the diagnostic centers. In order to minimize maintenance and operating risks, gaining efficiency, our facility was the first in Brazil to use the access to a cyclotron bunker via maze, rather than armored door stopper type. Materials: the design calculations were based on the Monte Carlo method (MCNP5 - Monte Carlo N-Particletransportcode version 5). At the ends of the labyrinth are installed a door of polyethylene, for thermalization of neutrons, and other of wood for limiting access. Both legs of the maze have wall thickness of 100cm. In inspection Brazilian CNEN realize measures of dose rate for neutrons and gamma 9 points: 7 around the bunker, 1 over the bunker and 1 in the exhaust with the cyclotron operating with maximum load, double beam of 50uA for 2 hours. After commissioning were carried out around the bunker, the following measures: cumulative dose in three months with dosimeters for neutron rate dose with a gas proportional detector type filled with 3 He and polyethylene neutron moderator and dose rate with a Geiger - Mueller detector for gamma radiation. Readings with neutron detectors were classified as background radiation and dose rates were always below the limits established in standard EN 3.01, and the calculation of the predicted regardless of the intensity of irradiation inside the bunker. Conclusion: the use of labyrinths as a way to access the bunkers cyclotron has been shown to be effective as the radiation shielding and efficient by allowing quick and easy access, virtually eliminating the maintenance

  4. The superconducting separated orbit cyclotron TRITRON

    International Nuclear Information System (INIS)

    Trinks, U.

    1984-01-01

    At the Munich 13 MV-Tandem Laboratory the TRITRON is under development, which will be the prototype of a superconducting separated orbit cyclotron for acceleration of heavy ions with 0.04 or approx.20) of the revolution frequency. Thus the frequency range for acceleration of ions with different revolution frequency can be kept small (+-3%). The magnets as well as the cavities are contained in the same cavity. (orig.)

  5. DAISY - the Oslo Cyclotron data acquisition system

    International Nuclear Information System (INIS)

    Ramsoey, T.

    1991-08-01

    The new CACTUS multidetector system for the Oslo Cyclotron consists of 8 particle telescopes, 28 NAI detectors and 2 Ge detectors. Each detector gives rise to one energy parameter and one time parameter. Thus, a total of 80 parameters are present. The counting rate is 100 kByte/s for the highest beam intensities. A new data acquisition system, DAISY, satisfying these demands has been designed. The present report is intended as a complete technical manual for the new system. 24 refs

  6. Electron cyclotron resonance multiply charged ion sources

    International Nuclear Information System (INIS)

    Geller, R.

    1975-01-01

    Three ion sources, that deliver multiply charged ion beams are described. All of them are E.C.R. ion sources and are characterized by the fact that the electrons are emitted by the plasma itself and are accelerated to the adequate energy through electron cyclotron resonance (E.C.R.). They can work without interruption during several months in a quasi-continuous regime. (Duty cycle: [fr

  7. Cyclotron heating rate in a parabolic mirror

    International Nuclear Information System (INIS)

    Smith, P.K.

    1984-01-01

    Cyclotron resonance heating rates are found for a parabolic magnetic mirror. The equation of motion for perpendicular velocity is solved, including the radial magnetic field terms neglected in earlier papers. The expression for heating rate involves an infinite series of Anger's and Weber's functions, compared with a single term of the unrevised expression. The new results show an increase of heating rate compared with previous results. A simple expression is given for the ratio of the heating rates. (author)

  8. First experimental observation of cyclotron superradiance

    Energy Technology Data Exchange (ETDEWEB)

    Ginzburg, N S; Zotova, I V; Sergeev, A S; Konoplev, I V [Russian Academy of Sciences, Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Shpak, V G; Yalandin, M I; Shunajlov, C A; Ulmaskulov, M P [Russian Academy of Sciences, Ekaterinburg (Russian Federation). Inst. of Electrophysics

    1997-12-31

    The first experimental observation of cyclotron superradiance from subnanosecond high-current electron bunches moving through waveguide systems is reported. Ultrashort microwave K{sub {alpha}} band pulses with a power of 200 kW and duration less than 0.5 ns were observed in the regime of group synchronism when the electron bunch drift velocity coincided with the group velocity of the electromagnetic waves. (author). 2 figs., 13 refs.

  9. Electron cyclotron emission measurement in Tore Supra

    International Nuclear Information System (INIS)

    Javon, C.

    1991-06-01

    Electron cyclotron radiation from Tore-Supra is measured with Michelson and Fabry-Perot interferometers. Calibration methods, essential for this diagnostic, are developed allowing the determination of electron temperature in the plasma. In particular the feasibility of Fabry-Perot interferometer calibration by an original method is demonstrated. A simulation code is developed for modelling non-thermal electron population in these discharges using measurements in non-inductive current generation regime [fr

  10. High Yield F-18 Target for KOTRON-13 Cyclotron

    International Nuclear Information System (INIS)

    Lee, W. K.; Song, J. Y.; Park, J. Y.; Jung, K. I.; Chae, S. K.

    2009-01-01

    Currently the domestic radiation market for medical diagnosis witnesses a high increase of the use of PET/CT for the purpose of cancer diagnosis, and the cases of cancer diagnosis using PET/CT increase by geometric progression every year. In case of domestic practice, full body scan is taken by using FDG medical isotope medicines mainly using F-18, but the necessity of various medical radioactive isotopes according to each medical purpose is increasing. F-18 output yield is directly proportional to energy of protons and beam current, and has correlation with heat production rate in case of target and decides the function of target in accordance with the efficiency of a cooling device. At present, in case of most F-18 target, when one irradiates beam in O-18 water of about 0.2∼5mL, one has to apply heat of over 300W, a high thermal energy per unit area is irradiated in target, which is easily damaged, and it has limitation in beam current. Currently, in case of commercial target, about 2,000W beam current is the maximum value, and in case of double-grid target developed by Korea Institute of Radiological and Medical Sciences in 2004, it was designed to stand up to about 1,000W theoretically, but in reality it can irradiate lower beam current than this because of the shortage of cooling efficiency. In general, the irradiation strength to produce radioactive isotopes given in the heat emission by target substance currently is limited to 50μA against target substance irradiated in 1.6mL. However, current KOTRON-13 cyclotron can accelerate proton beam with a high scope of strength marking 100μA thru 120μA by a continuous development. Therefore, it doesn't fully function compared with that of proton beam of KOTRON-13 cyclotron. The solution about this is to get over the problem of cooling target substance of cavity in the production system of radioactive isotopes. Especially, one has to develop the method to cool target substance, and provide higher F-18 yield than

  11. Barriers to the medication error reporting process within the Irish National Ambulance Service, a focus group study.

    Science.gov (United States)

    Byrne, Eamonn; Bury, Gerard

    2018-02-08

    Incident reporting is vital to identifying pre-hospital medication safety issues because literature suggests that the majority of errors pre-hospital are self-identified. In 2016, the National Ambulance Service (NAS) reported 11 medication errors to the national body with responsibility for risk management and insurance cover. The Health Information and Quality Authority in 2014 stated that reporting of clinical incidents, of which medication errors are a subset, was not felt to be representative of the actual events occurring. Even though reporting systems are in place, the levels appear to be well below what might be expected. Little data is available to explain this apparent discrepancy. To identify, investigate and document the barriers to medication error reporting within the NAS. An independent moderator led four focus groups in March of 2016. A convenience sample of 18 frontline Paramedics and Advanced Paramedics from Cork City and County discussed medication errors and the medication error reporting process. The sessions were recorded and anonymised, and the data was analysed using a process of thematic analysis. Practitioners understood the value of reporting errors. Barriers to reporting included fear of consequences and ridicule, procedural ambiguity, lack of feedback and a perceived lack of both consistency and confidentiality. The perceived consequences for making an error included professional, financial, litigious and psychological. Staff appeared willing to admit errors in a psychologically safe environment. Barriers to reporting are in line with international evidence. Time constraints prevented achievement of thematic saturation. Further study is warranted.

  12. Modular beam diagnostics instrument design for Cyclotrons

    International Nuclear Information System (INIS)

    Chaddha, N.; Bhole, R.B.; Sahoo, S.; Nandy, P.P.; Pal, S.

    2012-01-01

    The Cyclotrons at VECC, Kolkata i.e. Room Temperature Cyclotron (RTC) and Superconducting Cyclotron (SCC) comprise of internal and external Beam Diagnostic systems. These systems provide the beam developer with position, intensity, beam profile, a visual impression of the size and shape of ion beam, and operational control over diagnostic components like 3-finger probe, Beam Viewer probe, Deflector probe, Faraday cup, X-Y slit, Beam viewer etc. Automation of these components was initially done using customised modules for individual sub-system. An expansion of this facility and various levels of complexity demand modular design to cater easy modification and upgradation. The overall requirements are analysed and modular cards are developed based on basic functionalities like valve operation, probe/slit/viewer control, position read-out, Interlock, aperture control of beam line and communication. A 32-bit Advanced RISC Machine (ARM) based card with embedded EPICS is chosen as the master controller and FPGA/microcontroller is used for functional modules. The paper gives a comprehensive description of all modules and their integration with the control system. (author)

  13. Ion Cyclotron Heating on Proto-MPEX

    Science.gov (United States)

    Goulding, R. H.; Caughman, J. B. O.; Rapp, J.; Biewer, T. M.; Campbell, I. H.; Caneses, J. F.; Kafle, N.; Ray, H. B.; Showers, M. A.; Piotrowicz, P. A.

    2016-10-01

    Ion cyclotron heating will be used on Proto-MPEX (Prototype Material Plasma Exposure eXperiment) to increase heat flux to the target, to produce varying ion energies without substrate biasing, and to vary the extent of the magnetic pre-sheath for the case of a tilted target. A 25 cm long, 9 cm diameter dual half-turn helical ion cyclotron antenna has been installed in the device located at the magnetic field maximum. It couples power to ions via single pass damping of the slow wave at the fundamental resonance, and operates with ω 0.8ωci at the antenna location. It is designed to operate at power levels up to 30 kW, with a later 200 kW upgrade planned. Near term experiments include measuring RF loading at low power as a function of frequency and antenna gap. The plasma is generated by a helicon plasma source that has achieved ne > 5 ×1019m-3 operating with deuterium, as measured downstream from the ion cyclotron antenna location. Measurements will be compared with 1-D and 2-D models of RF coupling. The latest results will be presented. This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy.

  14. Electron cyclotron heating (ECH) of tokamak plasmas

    International Nuclear Information System (INIS)

    Hoshino, Katsumichi

    1990-01-01

    Electron cyclotron heating (ECH) is one of the intense methods of plasma heating, and which utilizes the collisionless electron-cyclotron-resonance-interaction between the launched electromagnetic waves (called electron cyclotron waves) and electrons which are one of the constituents of the high temperature plasmas. Another constituent, namely the ions which are subject to nuclear fusion, are heated indirectly but strongly and instantly (in about 0.1 s) by the collisions with the ECH-heated electrons in the fusion plasmas. The recent progress on the development of high-power and high-frequency millimeter-wave-source enabled the ECH experiments in the middle size tokamaks such as JFT-2M (Japan), Doublet III (USA), T-10 (USSR) etc., and ECH has been demonstrated to be the sure and intense plasma heating method. The ECH attracts much attention for its remarkable capabilities; to produce plasmas (pre-ionization), to heat plasmas, to drive plasma current for the plasma confinement, and recently especially by the localization and the spatial controllability of its heating zone, which is beneficial for the fine controls of the profiles of plasma parameters (temperature, current density etc.), for the control of the magnetohydrodynamic instabilities, or for the optimization/improvement of the plasma confinement characteristics. Here, the present status of the ECH studies on tokamak plasmas are reviewed. (author)

  15. Nonlinear cyclotron absorption and stimulated scattering

    International Nuclear Information System (INIS)

    Chung, T.H.

    1986-01-01

    In electron cyclotron resonance heating (ECRH), wave sources heating a plasma linearly with respect to intensity; but as the intensity of ECRH gets larger, there might appear nonlinear effects that would result in cutoff of net absorption. This thesis uses quantum mechanical theory to derive a threshold microwave intensity for nonlinear absorption. The quantum mechanical theory estimates that the threshold microwave intensity for nonlinear absorption is about 10 5 watts/cm 2 for a microwave heating experiment (T/sub e/ = 100 ev, λ = 3,783 cm, B = 2.5 kG). This value seems large considering the present power capabilities of microwave sources (10 2 ∼ 10 3 watts/cm 2 ), but for a low temperature plasma, this threshold will go down. There is another nonlinear phenomenon called stimulated cyclotron scattering that enhances photon scattering by electrons gyrating in a magnetic field. This is expected to prevent incoming photons from arriving at the central region of the fusion plasma, where absorption mainly takes place. Theory based on a photon transport model predicts that the threshold intensity for the stimulated cyclotron scattering is about 10 4 watts/cm 2 for the plasma parameters mentioned above. This value seems large also, but a longer wavelength of microwaves and a larger magnitude magnetic field, which will be the case in reactor type facilities, will lower the threshold intensity to levels comparable with the currently developed microwave sources

  16. Transparency of Magnetized Plasma at Cyclotron Frequency

    International Nuclear Information System (INIS)

    G. Shvets; J.S. Wurtele

    2002-03-01

    Electromagnetic radiation is strongly absorbed by a magnetized plasma if the radiation frequency equals the cyclotron frequency of plasma electrons. It is demonstrated that absorption can be completely canceled in the presence of a magnetostatic field of an undulator or a second radiation beam, resulting in plasma transparency at the cyclotron frequency. This effect is reminiscent of the electromagnetically induced transparency (EIT) of the three-level atomic systems, except that it occurs in a completely classical plasma. Unlike the atomic systems, where all the excited levels required for EIT exist in each atom, this classical EIT requires the excitation of the nonlocal plasma oscillation. The complexity of the plasma system results in an index of refraction at the cyclotron frequency that differs from unity. Lagrangian description was used to elucidate the physics and enable numerical simulation of the plasma transparency and control of group and phase velocity. This control naturally leads to applications for electromagnetic pulse compression in the plasma and electron/ion acceleration

  17. Improving cancer treatment with cyclotron produced radionuclides

    International Nuclear Information System (INIS)

    Larson, S.M.; Finn, R.D.

    1992-01-01

    Our goal is to improve the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The grant includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology; and Immunology. The radiochemistry group seeks to develop innovative cyclotron targetry, radiopharmaceuticals, and radiolabeled antibodies, which are then used to assess important unanswered questions in tumor pharmacology and immunology. Examples include selected positron emitting radionuclides, such as Iodine-124, and Ga-66; I-124, I-123, I-131 labeled iododeoxyuridine, C-11 colchicine, and antimetabolites, like C-11 methotrexate; and radiolabeled antibodies, 3F8, M195, A33, and MRK16 for application in the pharmacology and immunology projects. The pharmacology program studies tumor resistance to chemotherapy, particularly the phenomenon of multidrug resistance and the relationship between tumor uptake and retention and the tumor response for anti-metabolite drugs. The immunology program studies the physiology of antibody localization at the tissue level as the basis for novel approaches to improving tumor localization such as through the use of an artificial lymphatic system which mechanically reduces intratumoral pressures in tumors in vivo. Quantitative imaging approaches based on PET and SPECT in radioimmunotherapy are studied to give greater insight into the physiology of tumor localization and dosimetry

  18. Operation of a quasioptical electron cyclotron maser

    International Nuclear Information System (INIS)

    Morse, E.C.; Pyle, R.V.

    1984-12-01

    The electron cyclotron maser or gyrotron concept has been developed to produce sources producing 200 kW at 28 GHz continuously, and higher power outputs and frequencies in pulsed mode. These sources have been useful in electron cyclotron resonance heating (ECRH) in magnetically confined fusion devices. However, higher frequencies and higher power levels will be required in reactor-grade fusion plasmas, with likely requirements of 1.0 MW or more per source at 140 GHz. Conventional gyrotrons follow a trend of decreasing power for increasing frequency. In order to circumvent this problem, the quasioptical electron cyclotron maser was proposed. In this device, the closed resonator of the conventional gyrotron is replaced with an open, Fabry-Perot type resonator. The cavity modes are then the TEM-type modes of an optical laser. The advantage of this configuration is that the cavity size is not a function of frequency, since the length can be any half-integer number of wavelengths. Furthermore, the beam traverses across the cavity transverse to the direction of radiation output, and thus the rf window design is less complicated than in conventional tubes. The rf output, if obtained by diffraction coupling around one of the mirrors, could be in a TEM mode, which would allow for quasioptical transmission of the microwaves into the plasma in fusion devices. 4 references, 1 figure

  19. TFTR vertically viewing electron cyclotron emission diagnostic

    International Nuclear Information System (INIS)

    Taylor, G.

    1990-01-01

    The Tokamak Fusion Test Reactor (TFTR) Michelson interferometer has a spectral coverage of 75--540 GHz, allowing measurement of the first four electron cyclotron harmonics. Until recently the instrument has been configured to view the TFTR plasma on the horizontal midplane, primarily in order to measure the electron temperature profile. Electron cyclotron emission (ECE) extraordinary mode spectra from TFTR Supershot plasmas exhibit a pronounced, spectrally narrow feature below the second harmonic. A similar feature is seen with the ECE radiometer diagnostic below the electron cyclotron fundamental frequency in the ordinary mode. Analysis of the ECE spectra indicates the possibility of a non-Maxwellian 40--80 keV tail on the electron distribution in or near the core. During 1990 three vertical views with silicon carbide viewing targets will be installed to provide a direct measurement of the electron energy distribution at major radii of 2.54, 2.78, and 3.09 m with an energy resolution of approximately 20% at 100 keV. To provide the maximum flexibility, the optical components for the vertical views will be remotely controlled to allow the Michelson interferometer to be reconfigured to either the midplane horizontal view or one of the three vertical views between plasma shots

  20. Advance of the National Program of Radiological Protection and Safety for medical diagnostic with X-rays

    International Nuclear Information System (INIS)

    Verdejo S, M.

    1999-01-01

    The National Program of Radiological Protection and Safety for medical diagnostic with X-ray (Programa Nacional de Proteccion y Seguridad Radiologica para diagnostico medico con rayos X) was initiated in the General Direction of Environmental Health (Direccion General de Salud Ambiental) in 1995. Task coordinated with different dependences of the Public Sector in collaboration between the Secretary of Health (Secretaria de Salud), the National Commission of Nuclear Safety and Safeguards (Comision Nacional de Seguridad Nuclear y Salvaguardias) and, the National Institute of Nuclear Research (Instituto Nacional de Investigaciones Nucleares). The surveillance to the fulfilment of the standardization in matter of Radiological Protection and Safety in the medical diagnostic with X-rays has been obtained for an important advance in the Public sector and it has been arousing interest in the Private sector. (Author)

  1. Technical Note: Defining cyclotron-based clinical scanning proton machines in a FLUKA Monte Carlo system.

    Science.gov (United States)

    Fiorini, Francesca; Schreuder, Niek; Van den Heuvel, Frank

    2018-02-01

    Cyclotron-based pencil beam scanning (PBS) proton machines represent nowadays the majority and most affordable choice for proton therapy facilities, however, their representation in Monte Carlo (MC) codes is more complex than passively scattered proton system- or synchrotron-based PBS machines. This is because degraders are used to decrease the energy from the cyclotron maximum energy to the desired energy, resulting in a unique spot size, divergence, and energy spread depending on the amount of degradation. This manuscript outlines a generalized methodology to characterize a cyclotron-based PBS machine in a general-purpose MC code. The code can then be used to generate clinically relevant plans starting from commercial TPS plans. The described beam is produced at the Provision Proton Therapy Center (Knoxville, TN, USA) using a cyclotron-based IBA Proteus Plus equipment. We characterized the Provision beam in the MC FLUKA using the experimental commissioning data. The code was then validated using experimental data in water phantoms for single pencil beams and larger irregular fields. Comparisons with RayStation TPS plans are also presented. Comparisons of experimental, simulated, and planned dose depositions in water plans show that same doses are calculated by both programs inside the target areas, while penumbrae differences are found at the field edges. These differences are lower for the MC, with a γ(3%-3 mm) index never below 95%. Extensive explanations on how MC codes can be adapted to simulate cyclotron-based scanning proton machines are given with the aim of using the MC as a TPS verification tool to check and improve clinical plans. For all the tested cases, we showed that dose differences with experimental data are lower for the MC than TPS, implying that the created FLUKA beam model is better able to describe the experimental beam. © 2017 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists

  2. The Internet and healthcare in Taiwan: value-added applications on the medical network in the National Health Insurance smart card system.

    Science.gov (United States)

    Tsai, Wen-Hsien; Kuo, Hsiao-Chiao

    2007-01-01

    The introduction of smart card technology has ushered in a new era of electronic medical information systems. Taiwan's Bureau of National Health Insurance (BNHI) implemented the National Health Insurance (NHI) smart card project in 2004. The purpose of the project was to replace all paper cards with one smart card. The NHI medical network now provides three kinds of services. In this paper, we illustrate the status of the NHI smart card system in Taiwan and propose three kinds of value-added applications for the medical network, which are electronic exchange of medical information, retrieval of personal medical records and medical e-learning for future development of health information systems.

  3. arXiv Cyclotrons: Magnetic Design and Beam Dynamics

    CERN Document Server

    Zaremba, Simon

    Classical, isochronous, and synchro-cyclotrons are introduced. Transverse and longitudinal beam dynamics in these accelerators are covered. The problem of vertical focusing and iscochronism in compact isochronous cyclotrons is treated in some detail. Different methods for isochronization of the cyclotron magnetic field are discussed. The limits of the classical cyclotron are explained. Typical features of the synchro-cyclotron, such as the beam capture problem, stable phase motion, and the extraction problem are discussed. The main design goals for beam injection are explained and special problems related to a central region with an internal ion source are considered. The principle of a Penning ion gauge source is addressed. The issue of vertical focusing in the cyclotron centre is briefly discussed. Several examples of numerical simulations are given. Different methods of (axial) injection are briefly outlined. Different solutions for beam extraction are described. These include the internal target, extracti...

  4. Conversion of National Health Insurance Service-National Sample Cohort (NHIS-NSC) Database into Observational Medical Outcomes Partnership-Common Data Model (OMOP-CDM).

    Science.gov (United States)

    You, Seng Chan; Lee, Seongwon; Cho, Soo-Yeon; Park, Hojun; Jung, Sungjae; Cho, Jaehyeong; Yoon, Dukyong; Park, Rae Woong

    2017-01-01

    It is increasingly necessary to generate medical evidence applicable to Asian people compared to those in Western countries. Observational Health Data Sciences a Informatics (OHDSI) is an international collaborative which aims to facilitate generating high-quality evidence via creating and applying open-source data analytic solutions to a large network of health databases across countries. We aimed to incorporate Korean nationwide cohort data into the OHDSI network by converting the national sample cohort into Observational Medical Outcomes Partnership-Common Data Model (OMOP-CDM). The data of 1.13 million subjects was converted to OMOP-CDM, resulting in average 99.1% conversion rate. The ACHILLES, open-source OMOP-CDM-based data profiling tool, was conducted on the converted database to visualize data-driven characterization and access the quality of data. The OMOP-CDM version of National Health Insurance Service-National Sample Cohort (NHIS-NSC) can be a valuable tool for multiple aspects of medical research by incorporation into the OHDSI research network.

  5. Calculation of proton beam initial orbit at cyclotron central region

    International Nuclear Information System (INIS)

    Pramudita Anggraita

    2012-01-01

    A calculation of proton beam initial orbits at cyclotron central region was carried out using Scilab 5.2.0. The calculation was done in 2 dimensions in a homogeneous magnetic field of 1.66 tesla at frequency of fourth harmonics. The positions of ion source, dees, and dummy dees follow those of GE Minitrace cyclotron, peak dee voltage 30 kV. The calculation yields result comparable to those simulated at KIRAMS-13 cyclotron. (author)

  6. SU-E-P-19: A National Collaborative Academic Medical Physics Network: Structure, Activity and Outcomes

    International Nuclear Information System (INIS)

    Thwaites, D

    2015-01-01

    Purpose: A national Australian inter-university medical physics (MP) group was formed in 2011/12, supported by Department of Health Better Access to Radiation Oncology BARO) seed funding. Core membership includes the six universities providing postgraduate MP courses. Objectives include increasing capacity, development and efficiency of national academic MP structures/systems and hence supporting education, clinical training and research, for the MP workforce support. Although the BARO scheme focuses on Radiation Oncology, the group has wider MP interests. Methods: Two further BARO seed grants were achieved: 1) for networked academic activities, including shared-resource teaching, eg using virtual reality systems; MP outreach to schools and undergraduates; developing web-based student and registrar education/resources, etc.; and 2) for conjoint ‘translational research’ posts between universities and partner hospitals, to clinically progress advanced RT technologies and to support students and registrars. Each university received 0.5 FTE post from each grant over 2 years (total: $1.75M) and leveraged local additional partner funds. Results: Total funding: $4–5M. Overall there have been 35 (mainly overseas) postholders bringing specific expertise, beginning in early 2013. Periods in Australia have been from 0.25–2 years (median=1). As well as the education activities, research projects include lung/spine SBRT, 4D RT, FFF beams, technology assessment, complex treatment planning, imaging for radiation oncology, DIR, adaptive breast, datamining, radiomics,etc. Observed positive impacts include: increased interest in MP courses, training support, translational research infrastructure and/or clinical practice in the hospitals involved, plus increased collaboration and effectiveness between the universities. Posts are continuing beyond grant end using leveraged funds, providing the basis for sustainability of some posts. Conclusion: The BARO-funded projects have

  7. SU-E-P-19: A National Collaborative Academic Medical Physics Network: Structure, Activity and Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Thwaites, D [University of Sydney, Camperdown, Sydney (Australia)

    2015-06-15

    Purpose: A national Australian inter-university medical physics (MP) group was formed in 2011/12, supported by Department of Health Better Access to Radiation Oncology BARO) seed funding. Core membership includes the six universities providing postgraduate MP courses. Objectives include increasing capacity, development and efficiency of national academic MP structures/systems and hence supporting education, clinical training and research, for the MP workforce support. Although the BARO scheme focuses on Radiation Oncology, the group has wider MP interests. Methods: Two further BARO seed grants were achieved: 1) for networked academic activities, including shared-resource teaching, eg using virtual reality systems; MP outreach to schools and undergraduates; developing web-based student and registrar education/resources, etc.; and 2) for conjoint ‘translational research’ posts between universities and partner hospitals, to clinically progress advanced RT technologies and to support students and registrars. Each university received 0.5 FTE post from each grant over 2 years (total: $1.75M) and leveraged local additional partner funds. Results: Total funding: $4–5M. Overall there have been 35 (mainly overseas) postholders bringing specific expertise, beginning in early 2013. Periods in Australia have been from 0.25–2 years (median=1). As well as the education activities, research projects include lung/spine SBRT, 4D RT, FFF beams, technology assessment, complex treatment planning, imaging for radiation oncology, DIR, adaptive breast, datamining, radiomics,etc. Observed positive impacts include: increased interest in MP courses, training support, translational research infrastructure and/or clinical practice in the hospitals involved, plus increased collaboration and effectiveness between the universities. Posts are continuing beyond grant end using leveraged funds, providing the basis for sustainability of some posts. Conclusion: The BARO-funded projects have

  8. National Institutes of Health Funding to Departments of Orthopaedic Surgery at U.S. Medical Schools.

    Science.gov (United States)

    Silvestre, Jason; Ahn, Jaimo; Levin, L Scott

    2017-01-18

    The National Institutes of Health (NIH) is the largest supporter of biomedical research in the U.S., yet its contribution to orthopaedic research is poorly understood. In this study, we analyzed the portfolio of NIH funding to departments of orthopaedic surgery at U.S. medical schools. The NIH RePORT (Research Portfolio Online Reporting Tools) database was queried for NIH grants awarded to departments of orthopaedic surgery in 2014. Funding totals were determined for award mechanisms and NIH institutes. Trends in NIH funding were determined for 2005 to 2014 and compared with total NIH extramural research funding. Funding awarded to orthopaedic surgery departments was compared with that awarded to departments of other surgical specialties in 2014. Characteristics of NIH-funded principal investigators were obtained from department web sites. In 2014, 183 grants were awarded to 132 investigators at 44 departments of orthopaedic surgery. From 2005 to 2014, NIH funding increased 24.3%, to $54,608,264 (p = 0.030), but the rates of increase seen did not differ significantly from those of NIH extramural research funding as a whole (p = 0.141). Most (72.6%) of the NIH funding was awarded through the R01 mechanism, with a median annual award of $343,980 (interquartile range [IQR], $38,372). The majority (51.1%) of the total funds supported basic science research, followed by translational (33.0%), clinical (10.0%), and educational (5.9%) research. NIH-funded orthopaedic principal investigators were predominately scientists whose degree was a PhD (71.1%) and who were male (79.5%). Eleven NIH institutes were represented, with the National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS) providing the preponderance (74.2%) of the funding. In 2014, orthopaedic surgery ranked below the surgical departments of general surgery, ophthalmology, obstetrics and gynecology, otolaryngology, and urology in terms of NIH funding received. The percentage increase of NIH

  9. Evaluation of Speakers at a National Continuing Medical Education (CME Course

    Directory of Open Access Journals (Sweden)

    Jannette Collins, MD, MEd, FCCP

    2002-12-01

    Full Text Available Purpose: Evaluations of a national radiology continuing medical education (CME course in thoracic imaging were analyzed to determine what constitutes effective and ineffective lecturing. Methods and Materials: Evaluations of sessions and individual speakers participating in a five-day course jointly sponsored by the Society of Thoracic Radiology (STR and the Radiological Society of North America (RSNA were tallied by the RSNA Department of Data Management and three members of the STR Training Committee. Comments were collated and analyzed to determine the number of positive and negative comments and common themes related to ineffective lecturing. Results: Twenty-two sessions were evaluated by 234 (75.7% of 309 professional registrants. Eighty-one speakers were evaluated by an average of 153 registrants (range, 2 – 313. Mean ratings for 10 items evaluating sessions ranged from 1.28 – 2.05 (1=most positive, 4=least positive; SD .451 - .902. The average speaker rating was 5.7 (1=very poor, 7=outstanding; SD 0.94; range 4.3 – 6.4. Total number of comments analyzed was 862, with 505 (58.6% considered positive and 404 (46.9% considered negative (the total number exceeds 862 as a “comment” could consist of both positive and negative statements. Poor content was mentioned most frequently, making up 107 (26.5% of 404 negative comments, and applied to 51 (63% of 81 speakers. Other negative comments, in order of decreasing frequency, were related to delivery, image slides, command of the English language, text slides, and handouts. Conclusions: Individual evaluations of speakers at a national CME course provided information regarding the quality of lectures that was not provided by evaluations of grouped presentations. Systematic review of speaker evaluations provided specific information related to the types and frequency of features related to ineffective lecturing. This information can be used to design CME course evaluations, design future CME

  10. Suppression of cyclotron instability in Electron Cyclotron Resonance ion sources by two-frequency heating

    International Nuclear Information System (INIS)

    Skalyga, V.; Izotov, I.; Mansfeld, D.; Kalvas, T.; Koivisto, H.; Komppula, J.; Kronholm, R.; Laulainen, J.; Tarvainen, O.

    2015-01-01

    Multiple frequency heating is one of the most effective techniques to improve the performance of Electron Cyclotron Resonance (ECR) ion sources. The method increases the beam current and average charge state of the extracted ions and enhances the temporal stability of the ion beams. It is demonstrated in this paper that the stabilizing effect of two-frequency heating is connected with the suppression of electron cyclotron instability. Experimental data show that the interaction between the secondary microwave radiation and the hot electron component of ECR ion source plasmas plays a crucial role in mitigation of the instabilities

  11. Proceedings of eighth joint workshop on electron cyclotron emission and electron cyclotron resonance heating. Vol. 1

    International Nuclear Information System (INIS)

    1993-03-01

    The theory of electron cyclotron resonance phenomena is highly developed. The main theoretical tools are well established, generally accepted and able to give a satisfactory description of the main results obtained in electron cyclotron emission, absorption and current drive experiments. In this workshop some advanced theoretical and numerical tools have been presented (e.g., 3-D Fokker-Planck codes, treatment of the r.f. beam as a whole, description of non-linear and finite-beam effects) together with the proposal for new scenarios for ECE and ECA measurements (e.g., for diagnosing suprathermal populations and their radial transport). (orig.)

  12. Proceedings of eighth joint workshop on electron cyclotron emission and electron cyclotron resonance heating. Vol. 2

    International Nuclear Information System (INIS)

    1993-03-01

    The theory of electron cyclotron resonance phenomena is highly developed. The main theoretical tools are well established, generally accepted and able to give a satisfactory description of the main results obtained in electron cyclotron emission, absorption and current drive experiments. In this workshop some advanced theoretical and numerical tools have been presented (e.g., 3-D Fokker-Planck codes, treatment of the r.f. beam as a whole, description of non-linear and finite-beam effects) together with the proposal for new scenarios for ECE and ECA measurements (e.g., for diagnosing suprathermal populations and their radial transport). (orig.)

  13. Medications

    Science.gov (United States)

    ... Red Dress ® , and Red Dress ® are registered trademarks of U.S. Department of Health and Human Services. National Wear Red Day ® is a registered trademark of the U.S. Department of Health and Human ...

  14. Relationship between National Institutes of Health research awards to US medical schools and managed care market penetration.

    Science.gov (United States)

    Moy, E; Mazzaschi, A J; Levin, R J; Blake, D A; Griner, P F

    1997-07-16

    Medical research conducted in academic medical centers is often dependent on support from clinical revenues generated in these institutions. Anecdotal evidence suggests that managed care has the potential to affect research conducted in academic medical centers by challenging these clinical revenues. To examine whether empirical evidence supports a relationship between managed care and the ability of US medical schools to sustain biomedical research. Data on annual extramural research grants awarded to US medical schools by the National Institutes of Health (NIH) from fiscal years 1986 to 1995 were obtained, and each medical school was matched to a market for which information about health maintenance organization (HMO) penetration in 1995 was available. Growth in total NIH awards, traditional research project (R01) awards, R01 awards to clinical and basic science departments, and changes in institutional ranking by NIH awards were compared among schools located in markets with low, medium, and high managed care penetration. Medical schools in all markets had comparable rates of growth in NIH awards from 1986 to 1990. Thereafter, medical schools in markets with high managed care penetration had slower growth in the dollar amounts and numbers of NIH awards compared with schools in markets with low or medium managed care penetration. This slower growth for schools in high managed care markets was associated with loss of share of NIH awards, equal to $98 million in 1995, and lower institutional ranking by NIH awards. Much of this revenue loss can be explained by the slower growth of R01 awards to clinical departments in medical schools in high managed care markets. These findings provide evidence of an inverse relationship between growth in NIH awards during the past decade and managed care penetration among US medical schools. Whether this association is causal remains to be determined.

  15. Cyclotron will not survive yet this year without state support

    International Nuclear Information System (INIS)

    Marcan, P.

    2005-01-01

    In this paper the project of the Cyclotron Center of the Slovak republic is described. On the basis of this project the state joint-stock company Biont was constituted. Small cyclotron is in operation; big cyclotron is in process of manufacture and it will be put in operation in 2007. Small cyclotron will be used for production of radiopharmaceuticals. Positron emission tomograph (PET) in Oncological Institute of St. Elizabeth (in Bratislava) and gamma camera in Central Military Hospital (in Ruzomberok) are constituents of the Biont. The PET will be also in Biont. The hadron therapy of ophthalmic tumors is planned. Financial plans of the Biont up to 2009 are presented

  16. The European Federation of Organisations for Medical Physics Policy Statement No. 10.1: Recommended Guidelines on National Schemes for Continuing Professional Development of Medical Physicists.

    Science.gov (United States)

    Christofides, Stelios; Isidoro, Jorge; Pesznyak, Csilla; Cremers, Florian; Figueira, Rita; van Swol, Christiaan; Evans, Stephen; Torresin, Alberto

    2016-01-01

    Continuing Professional Development (CPD) is vital to the medical physics profession if it is to embrace the pace of change occurring in medical practice. As CPD is the planned acquisition of knowledge, experience and skills required for professional practice throughout one's working life it promotes excellence and protects the profession and public against incompetence. Furthermore, CPD is a recommended prerequisite of registration schemes (Caruana et al. 2014) and is implied in the Council Directive 2013/59/EURATOM (EU BSS) and the International Basic Safety Standards (BSS). It is to be noted that currently not all national registration schemes require CPD to maintain the registration status necessary to practise medical physics. Such schemes should consider adopting CPD as a prerequisite for renewing registration after a set period of time. This EFOMP Policy Statement, which is an amalgamation and an update of the EFOMP Policy Statements No. 8 and No. 10, presents guidelines for the establishment of national schemes for CPD and activities that should be considered for CPD. Copyright © 2016. Published by Elsevier Ltd.

  17. Cyclotron based nuclear science. Progress report, April 1, 1985-March 31, 1986

    International Nuclear Information System (INIS)

    Youngblood, D.H.

    1986-08-01

    Progress report for cyclotron based nuclear science cyclotron facility are summarized. Research is described under the headings heavy ion reactions, nuclear theory, atomic studies and activation analysis, superconducting cyclotron and instrumentation. Publications are listed

  18. National Clinical Skills Competition: an effective simulation-based method to improve undergraduate medical education in China

    Directory of Open Access Journals (Sweden)

    Guanchao Jiang

    2016-02-01

    Full Text Available Background: The National Clinical Skills Competition has been held in China for 5 consecutive years since 2010 to promote undergraduate education reform and improve the teaching quality. The effects of the simulation-based competition will be analyzed in this study. Methods: Participation in the competitions and the compilation of the questions used in the competition finals are summarized, and the influence and guidance quality are further analyzed. Through the nationwide distribution of questionnaires in medical colleges, the effects of the simulation-based competition on promoting undergraduate medical education reform were evaluated. Results: The results show that approximately 450 students from more than 110 colleges (accounting for 81% of colleges providing undergraduate clinical medical education in China participated in the competition each year. The knowledge, skills, and attitudes were comprehensively evaluated by simulation-based assessment. Eight hundred and eighty copies of the questionnaires were distributed to 110 participating medical schools in 2015. In total, 752 valid responses were received across 95 schools. The majority of the interviewees agreed or strongly agreed that competition promoted the adoption of advanced educational principles (76.8%, updated the curriculum model and instructional methods (79.8%, strengthened faculty development (84.0%, improved educational resources (82.1%, and benefited all students (53.4%. Conclusions: The National Clinical Skills Competition is widely accepted in China. It has effectively promoted the reform and development of undergraduate medical education in China.

  19. National Clinical Skills Competition: an effective simulation-based method to improve undergraduate medical education in China.

    Science.gov (United States)

    Jiang, Guanchao; Chen, Hong; Wang, Qiming; Chi, Baorong; He, Qingnan; Xiao, Haipeng; Zhou, Qinghuan; Liu, Jing; Wang, Shan

    2016-01-01

    The National Clinical Skills Competition has been held in China for 5 consecutive years since 2010 to promote undergraduate education reform and improve the teaching quality. The effects of the simulation-based competition will be analyzed in this study. Participation in the competitions and the compilation of the questions used in the competition finals are summarized, and the influence and guidance quality are further analyzed. Through the nationwide distribution of questionnaires in medical colleges, the effects of the simulation-based competition on promoting undergraduate medical education reform were evaluated. The results show that approximately 450 students from more than 110 colleges (accounting for 81% of colleges providing undergraduate clinical medical education in China) participated in the competition each year. The knowledge, skills, and attitudes were comprehensively evaluated by simulation-based assessment. Eight hundred and eighty copies of the questionnaires were distributed to 110 participating medical schools in 2015. In total, 752 valid responses were received across 95 schools. The majority of the interviewees agreed or strongly agreed that competition promoted the adoption of advanced educational principles (76.8%), updated the curriculum model and instructional methods (79.8%), strengthened faculty development (84.0%), improved educational resources (82.1%), and benefited all students (53.4%). The National Clinical Skills Competition is widely accepted in China. It has effectively promoted the reform and development of undergraduate medical education in China.

  20. [(Inter)national and regional health goals in academic social-medical education conception for teaching medical students at the Eberhard Karls University Tuebingen].

    Science.gov (United States)

    Simoes, E; Hildenbrand, S; Rieger, M A

    2012-07-01

    Social medicine deals with the specific interactions between medicine and society within a constantly changing social environment. The Institute of Occupational and Social Medicine, University Hospital Tuebingen, focuses on this relationship within the academic teaching of the Medical Faculty. Many of the issues thus directly affect the national health objectives and especially the health targets of the state of Baden-Württemberg, summarised in the Health Strategy Baden-Wuerttemberg. In addition to the recommendations of the German Society for Social Medicine and Prevention (DGSMP) for the social medicine curriculum and the specific definition of the content by the Tuebingen medical faculty, national and regional health-care goals are also taken into account in the teaching conception. Classes are increasingly offered as training courses in small groups (seminars, group work with practical training), instead of classic lectures. These teaching methods allow the students to take part more actively in social medicine issues and to think and act within a comprehensive understanding of health management based on societal goals and the needs of a good health system. The concept is supported by the curriculum design element "log-book skills" of the Medical Faculty of Tuebingen. Feedback elements for teachers and students shape the further development of the concept. In dealing with real system data, practical experience on site and case vignettes, the students experience the links between societal influences, political objectives and medical action as well as the importance of accessibility of medical services for equity in health chances. The fact that advice and expertise play a crucial role in accessibility is a component to which too little attention is paid and calls for emphasis in the teaching concept. This teaching approach will deepen the understanding of the influence of psychosocial context factors and the conditions of the structural framework on the medical