Sample records for nasolacrimal polyurethane stents

  1. Nasolacrimal Polyurethane Stent: Complications with CT Correlation

    International Nuclear Information System (INIS)

    Pinto, Isabel T.; Paul, Laura; Grande, Carlos

    1998-01-01

    Purpose: To evaluate initial results in patients with epiphora secondary to obstruction of the nasolacrimal duct treated by placement of a polyurethane stent, and to discuss the technical problems and complications arising during the procedure, with visualization of the anatomy of the drainage apparatus using computed tomography (CT). Methods: We inserted 20 polyurethane Song stents under fluoroscopic guidance after dacryocystography in 19 patients with grade 3-4 epiphora caused by idiopathic obstruction of the nasolacrimal duct. CT scans were obtained following stent placement in all patients. Results: We focus on the technical problems and complications that arose during these procedures. During negotiation of the guidewire past the obstruction at the level of the junction of the duct with the lacrimal sac, the guidewire created a false passage in a posterior suborbital direction in two cases and towards the posterior midline in another. In all cases the guidewire was withdrawn and reinserted through the proper anatomic route without further difficulty or complications. In two cases the stent was improperly positioned wholly or partially outside the nasolacrimal system (one medially, one posteriorly). In one case the stent was removed and reinserted; in the other it remains in place and functional. CT was performed in all these cases to ensure proper anatomic alignment and determine what had gone wrong. The epiphora was completely resolved in 13 cases and partially relieved in four; there were three cases of stent obstruction. Epistaxis of short duration (1 hr) occurred in seven patients and headache in one. Conclusions: Treatment of epiphora with polyurethane stents is a technique that is well tolerated by patients and achieves a high success rate, yet problems in placement may be encountered. Though no major consequences for patients are involved, cognizance of such difficulties is important to avoid incorrect positioning of stents

  2. Evaluation of Polyurethane Nasolacrimal Duct Stents: In Vivo Studies in New Zealand Rabbits

    International Nuclear Information System (INIS)

    Wilhelm, K.E.; Grabolle, B.; Urbach, H.; Tolba, R.; Schild, H.; Paulsen, F.

    2006-01-01

    The purpose of this study was to evaluate the radiographic and biological effects of different polyurethane nasolacrimal duct stents in an animal model. Fifteen polyurethane nasolacrimal duct stents (n = 5 mushroom-type stents, n = 5 newly designed S-shaped TearLeader stents without hydrophilic coating, and n = 5 S-shaped TearLeader stents with hydrophilic coating) were implanted in the nasolacrimal ducts of eight unaffected New Zealand rabbits. One nasolacrimal system served as control. Clinical and radiographic follow-up was performed at 1-, 2-, and 4-week intervals, then after a 3-month interval, after which the animals were euthanized. All stents were implanted without major periprocedural complications. The stents proved to be patent by the end of the procedure. During follow-up, all mushroom-type stents were occluded at 4 weeks. None of these stents opened to forced irrigation. Clinically, all rabbits demonstrated severe dacryocystitis. Three out of five TearLeader stents without hydrophilic coating were blocked at 4 weeks; one out of five was open to irrigation. Best results were observed in the stent group with hydrophilic coating. Follow-up dacryocystography demonstrated patent stents in nasolacrimal ducts of all animals after 4 weeks. In only one of five cases, the coated stent became partially occluded after 2 months. These animals were free of clinical symptoms. After 3 months, at least three out of five stents still opened to forced irrigation and only one stent was completely blocked. Dislocation of the stents was not observed. Refinement of the stent surface and stent design improves the results of nasolacrimal duct stenting in this animal model. Implantation of hydrophilic-coated S-shaped stents is highly superior to conventional mushroom-type stents and noncoated stent types. Hydrophilic coating seems to prevent foreign-body reactions, resulting in maximized stent patency

  3. Treatment of Complete and Partial Obstruction of the Nasolacrimal System with Polyurethane Stents: Initial Experience

    International Nuclear Information System (INIS)

    Pulido-Duque, Juan M.; Reyes, Ricardo; Carreira, Jose M.; Vega, Francisco; Gorriz, Elias; Pardo, M. Dolores; Perez, Francisco; Maynar, Manuel

    1998-01-01

    Purpose: To present our experience in the treatment of nasolacrimal occlusion by means of polyurethane stents. Methods: Forty polyurethane stents were placed under fluoroscopic guidance in 35 consecutive patients with epiphora due to total or partial obstruction of the nasolacrimal system. The set designed by Song was used in all patients. The procedure was performed by introducing a guidewire through the superior punctum into the canaliculus and advancing it across the obstruction into the inferior meatus of the nasal cavity. After pulling out the guidewire, the stent was advanced in retrograde fashion and released into the sac and the nasolacrimal duct.Results: The technical success rate was 100%. The average time for the procedure was 25 min (range 10-60 min). Immediate complications were: mild pain (n= 5), severe pain (n= 1), minimal epistaxis (n= 7), and moderate epistaxis (n= 1). No major complications occurred. The last clinical control revealed complete resolution of epiphora in 35 eyes and partial resolution in four; one patient did not improve. Conclusion: This technique for treatment of obstruction of the nasolacrimal system is simple and safe, and may obviate the use of more invasive procedures

  4. Modified nasolacrimal duct stenting

    International Nuclear Information System (INIS)

    Tian Min; Jin Mei; Chen Huanjun; Li Yi

    2008-01-01

    Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of eye-nose-mouth-nose of external nasal guide wire track can improve the successful rate of nasolacrimal duct stenting. (authors)

  5. Implante de ducto nasolacrimal de poliuretano: relato de caso Nasolacrimal stent implantation: report of a case

    Directory of Open Access Journals (Sweden)

    Patrícia Lunardelli

    2008-02-01

    procedure was performed in the "Hospital das Clínicas" of the University of São Paulo - USP. A female patient with tearing of the right eye and secretion was submitted to a nasolacrimal stent implantation, with fluoroscopic guidance. The stent used in this procedure was the polyurethane Tearleader stent set. (Dr. Wilhelm type-PBN MEDICALS - Denmark. After 3 months, the patient started complaining of tearing, so the stent was removed and the patient was submitted to an external dacryocystorhinostomy. At present the patient does not have any symptoms or complaints. This procedure is less invasive and simple, causes no facial scars and avoids surgical trauma, but the long term success rates achieved using polyurethane nasolacrimal stents are low as compared with the external dacryocystorhinostomy. In addition, the patients usually complaint of tearing even having patent lacrimal system. In summary, long-term studies are needed to resolve some complications. Maybe a new stent design and new methods of unblocking the stent in situ would improve in the near future the levels of patency that currently are modest.

  6. Invention of a nasolacrimal stent retrieval hook

    International Nuclear Information System (INIS)

    Kim, Tae Hyung; Kim, Yeong Kyun; Park, Sang Soo; Song, Ho Young

    1997-01-01

    To evaluate the clinical usefulness of a nasolacrimal stent retrieval hook The retrieval hook consisted of two parts, a hook and pusher. The head of the hook part was made of 0.7mm stainless steel wire and was question mark-shaped, while the body of this part was constructed by soldering together four stainless steel pipes ranging in thickness from 1.25 to 3.5mm, serially. The pusher part was made of two plastic tubes and was designed in such a way that the hook grasped the stent tightly. The device was used to remove 46 stents in 40 patients, and tested for 1) average number of trials;2) success rate;and 3) average time of the procedure. The average number of trials, success rate, and average time taken to remove the stent was 4.7, 91%, and 1.8 minutes, respectively. In the removal of nasolacrimal stents, the retrieval hook was easy to use, useful and effective

  7. Nasolacrimal Stenting: Toward Improving Outcomes with a Simple Modification of the Song Stent

    International Nuclear Information System (INIS)

    Lanciego, Carlos; Miguel, Silvia De; Padilla, Manuel; Perea, Miguel; Rodriguez-Merlo, Rufo; Garcia-Garcia, Lorenzo

    2006-01-01

    The purpose of this study was to evaluate, in a prospective, single-center study, the effectiveness of Song's polyurethane stents, modified 'in-house,' in the percutaneous management of epiphora. Patients (n = 170; age range 18-83, mean = 64; 50 male, 120 female) with severe epiphora had the modified stents inserted (183 eyes/195 stents) to treat unilateral/bilateral and complete/partial obstruction of the nasolacrimal system. The etiology of the obstruction was idiopathic in 119 cases (61%) and chronic dacryocystitis in 76 (39%). The set designed by Song was used in all patients but modified by us such that the extreme end is cone-shaped. The original technique was slightly modified by us and the procedure was conducted on an outpatient basis. The initial technical success rate of stent placement was 97%. Resolution of epiphora was complete in 180 eyes and partial in 3. On follow-up (mean = 18 months; range: 2 days to 24 months), 165 of 195 stents (85%) remained patent. Primary patency rates at follow-up were 86%, 84%, 84%, and 79% in the first 6 months, second and third 6 months, and the present (24 months), respectively. Stents became obstructed in 30 patients, but all but 2 were easily withdrawn and 20 of these patients remained asymptomatic for a mean of 14 months (secondary patency of 67%). Following stent removal, the withdrawn stent was replaced with a new stent in the same intervention on 14 occasions. In another six cases, patency was re-established without the need of a second stent. The procedure is simple and safe, both in stent insertion as well as in mechanical de-blocking and withdrawal when occluded. Success was >80 % in the short term (1-year follow-up). Stenting failure does not preclude other treatment because with the modification that we had introduced, the extreme end of the stent becomes more accessible to mechanical de-blocking, withdrawal, and relocation. The levels of primary and secondary patencies are promising and warrant more

  8. Usefulness of a hook in nasolacrimal balloon dilatation and stent placement

    International Nuclear Information System (INIS)

    Kim, Tae Hyung; Song, Ho Young; Son, Jin Hyun; Park, Sang Soo

    1996-01-01

    To evaluate the usefulness of a hook developed for pulling out the guide wire in nasolacrimal balloon dilatation and stent placement. The head was made of stainless steel wire in a shape of a question mark, and the body was made of four stainless steel pipes. The head was attached to the body in three different ways:A) the head was anterior to the body, B) the head was posterior to the body, and C) the head was angled of 30 degrees forward from the direction of the body. 90 epiphora patients took part in a test to compare and evalvate the usefulness of different types of hook. Average number of trials, success rate and average time of the procedure were recorded. The average trial number for different attachment methods A, B, and C was 4.5, 6.4, and 2.5, respectively, and the success rate 83, 70, and 97%, respectively. The average time of the procedure was 31 minutes. The C type hook was the most effective, and the new technique using the hook was more convenient and time-saving than the old technique using a nasal endoscopy

  9. Treating Epiphora in Adults With the Wilhelm Plastic Nasolacrimal Stent: Mid-Term Results of a Prospective Study

    International Nuclear Information System (INIS)

    Ciampi, Juan J.; Lanciego, Carlos; Navarro, Sofia; Cuena, Rafael; Velasco, Javier; Perea, Miguel; García-García, Lorenzo

    2011-01-01

    The objective of the present study was to evaluate, in a prospective, single-center study, the effectiveness of the Wilhelm-type stent used in interventional radiology for the management of epiphora. Patients (n = 104; mean age 64 [range 25–88]; 33 male and 71 female) with severe epiphora had the stents inserted (135 stents in 115 eyes) to treat obstruction of the nasolacrimal system. The etiology of the obstruction was idiopathic in 83 cases, chronic dacryocystitis in 31, cases and postsurgical status in 1 case. The overall technical success rate of stent placement was near 94%. Resolution of epiphora was complete in 105 cases and partial in 3 cases. During a mean 13-month follow-up (range 1 week to 28 months), the median duration of primary patency was 11 months, and the percentage of patency at 6 months was 60.8%, at 1 year was 39.6%, and at 2 years was 25%. Stents malfunctioned in 54 cases, and all were easily withdrawn except in 1 case. Of these 27 cases, patency recovered spontaneously in 9 and by way of a second stent in 18. Secondary patency was 50%. Factors presdisposing to lower primary patency are inflammatory etiology and location of the obstruction. The benefit of stent deployment is clear with respect to the resolution of epiphora in candidate patients for percutaneous treatment. Technical and/or design improvements would be welcomed.

  10. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  11. Amblyopia risk factors in infants with congenital nasolacrimal duct obstruction.

    Science.gov (United States)

    Kim, Jung Wan; Lee, Hwa; Chang, Minwook; Park, Minsoo; Lee, Tae Soo; Baek, Sehyun

    2013-07-01

    This study aims to report the prevalence of amblyopia risk factors in patients with congenital nasolacrimal duct obstructions. We recruited patients who were treated for congenital nasolacrimal duct obstruction from April 2007 to December 2011 at Korea University Ansan Hospital. We evaluated visual acuity and refraction, performed strabismus test and slit-lamp examination, and assessed marginal reflex distance 1 (MRD1) to rule out amblyopia risk factors. We examined 26 children among 115 patients. Ten patients underwent probing procedure and 16 underwent Monoka stent intubation. Nine (35%) patients showed amblyopia risk factors, which occurred in the same eye as the congenital nasolacrimal duct obstruction in 8 (89%) patients. Seven out of 9 patients had refractive error alone, and 2 patients had both refractive error and strabismus. One (11%) had anisometropia, 2 (22%) had hyperopia, and 8 (89%) had astigmatism. Children with congenital nasolacrimal duct obstruction had a higher prevalence of amblyopia risk factors than children in the general population. Children with congenital nasolacrimal duct obstruction require special attention and treatments for refractive error. We recommend early treatment, such as probing or intubation, for congenital nasolacrimal duct obstruction.

  12. Polyrethene nasolacrimal prostheses. Assessment of the complications using computed tomography

    International Nuclear Information System (INIS)

    Pino, I. T.; Paul, L.; Duran, M. A.; Grande, C.

    1999-01-01

    To assess the outcome of treatment of epiphora secondary to nasolacrimal duct obstruction by placement of a polyurethane prosthesis. We placed 20 polyurethane prostheses (song's prostheses) in 19 patients with nasolacrimal duct obstruction who presented idiopathic grade III-IV epiphora. All the patients underwent CT with follow-up studies 10 days, one month and three months after prosthesis placement. Epiphora resolved completely in 13 cases and partially in four. In two cases, the prosthesis was poorly positioned; one of them was replaced and the other functions to date. There were three cases of obstruction. We observed limited epistaxis in 7 patients and headache in one. The treatment of epiphora by polyurethane prosthesis placement is a simple procedure that is well tolerated by patients and has a high success rate. (Author) 14 refs

  13. Nasolacrimal relapse of nasopharyngeal carcinoma.

    Science.gov (United States)

    Sia, K J; Tang, I P; Kong, C K L; Tan, T Y

    2012-08-01

    To describe three rare cases of nasolacrimal relapse of nasopharyngeal carcinoma, and to discuss the route of tumour spread from nasopharynx to lacrimal system as well as the relevant computed tomography findings. We report three cases of nasolacrimal relapse in patients with previously treated nasopharyngeal carcinoma. The common initial presentations in these cases were epiphora and medial canthal swelling. The tumour spread from the nasopharynx to the lacrimal sac along the lateral nasal wall and nasolacrimal canal. Computed tomography demonstrated nasolacrimal canal invasion and osteomeatal complex obliteration by the tumour. Distant metastasis was detected in two cases. More targeted radiotherapy should be delivered to prevent under-treatment of nasopharyngeal carcinoma. Nasolacrimal relapse of nasopharyngeal carcinoma is an advanced disease with a poor prognosis.

  14. In Vivo Study of Polyurethane-Coated Gianturco-Rosch Biliary Z-Stents

    International Nuclear Information System (INIS)

    Severini, Aldo; Mantero, Sara; Tanzi, Maria Cristina; Cigada, Alberto; Addis, Flaminio; Cozzi, Guido; Salvetti, Monica; Andreola, Salvatore; Motta, Antonella; Regalia, Enrico; Pulvirenti, Andrea; De Pedri, Enrico; Doci, Roberto

    1999-01-01

    Purpose: Prototypes of Gianturco-Rosch Z-stents coated with polycarbonate urethane (PCU) were placed in the biliary tree of pigs, in order to test their biomechanical behavior, stability, and biocompatibility. Methods: The stents were surgically implanted in the common bile duct of three pairs of pigs, which were killed after 1, 3, and 6 months respectively. Explanted livers from pigs of the same race, age, and size were used to provide comparative data. The bile ducts were radiologically and histopathologically examined; the stents were processed and examined by scanning electron microscopy. Results: No complications occurred and the animals showed a normal weight gain. The main bile duct appeared radiologically and macroscopically dilated, but the stents proved to be in place. Histologically, the bile duct epithelium was destroyed, but neither hyperplastic nor inflammatory fibrotic reactions of the wall were evident. Both the metallic structure and the polymeric coating of the stents were intact. A layer of organic material with a maximum thickness of approximately 3 μm was evident on the inner surface of the stents. Conclusion: The present in vivo study demonstrates the biocompatibility, efficacy, and stability of PCU-coated Gianturco-Rosch stents in the biliary environment

  15. Stent

    Science.gov (United States)

    ... Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Stent URL of this page: //medlineplus.gov/ency/article/002303.htm Stent To use the sharing features on this page, please enable JavaScript. A stent is a tiny tube placed into a hollow structure in your ...

  16. COMPARATIVE ANALYSIS OF EFFICIENCY OF NANOSTRUCTURED AND POLYURETHANE STENTS FOR DRAINAGE OF THE UPPER URINARY TRACT IN EXPERIMENT

    Directory of Open Access Journals (Sweden)

    S. V. Shkodkin

    2012-01-01

    Full Text Available This article presents the results of a pilot study of experimental stent in comparison to traditionally used. Experi- ments were performed on 20 adult male rabbits weighing 4350–4580 grams. The main study group (10 animals was performed an experimental unilateral implantation of the stent, as a control (10 animals was performed a unilateral stent implantation «White-star standart» (Company Urotech, Germany, of the same diameter. The observation period was 1 month. There were performed laboratory tests of blood and urine, as well as morpholo- gical examination of the kidneys and ureters. We obtain statistically significant benefits of using an experimental stent

  17. Xylometazoline hydrochloride nasal spray combined with laser artificial nasolacrimal duct implantation for nasolacrimal duct obstruction

    Directory of Open Access Journals (Sweden)

    Xiao-Zhao Yang

    2017-02-01

    Full Text Available AIM: To study the role of xylometazoline hydrochloride nasal spray in combination therapy of nasolacrimal duct obstruction and to investigate the effect of nasal inflammation on nasolacrimal duct obstruction. METHODS: Totally 279 patients with nasolacrimal duct obstruction were collected, who received lacrimal passage irrigation, CT angiography for lacrimal passage and nasal endoscope before treated by lacrimal laser forming and artificial nasolacrimal duct implantation combined with xylometazoline hydrochloride nasal spray. In group A, 137 patients were treated with antibiotic eye drop and non-steroidal anti-inflammatory drugs after operations. In group B, 142 patients were treated with xylometazoline hydrochloride nasal spray besides the same treatment for group A. RESULTS:In the 279 patients 217(77.8%, in which 105 cases(76.6%were in group A and 112 cases(78.9%were in group B, were suffered with nasal inflammation, including nasal mucosal hyperemia, inferior turbinate hypertrophy, middle turbinate hypertrophy. At 3mo after the ducts were drawn, efficacy of group B was 95.8%, which was significant better than that of group A(86.1%, PCONCLUSION: Nasal inflammation was an important factor in the incidence of nasolacrimal duct obstruction, which shoud pay more attention in the process of diagnosis and treatment. Combination therapy could improve the cure rate of nasolacrimal duct obstruction.

  18. Nasolacrimal recanalization as an alternative to external dacryocystorhinostomy for treating failed nasolacrimal duct intubation.

    Science.gov (United States)

    Hong, Jiaxu; Qian, Tingting; Wei, Anji; Sun, Zhongmou; Wu, Dan; Chen, Yihe; Marmalidou, Anna; Lu, Yi; Sun, Xinghuai; Liu, Zuguo; Amparo, Francisco; Xu, Jianjiang

    2016-07-01

    To compare the surgical duration and clinical outcomes of nasolacrimal recanalization versus external dacryocystorhinostomy (DCR) in the treatment of failed nasolacrimal duct intubation.This is a retrospective, comparative, and interventional study. We evaluated the outcomes of 66 consecutive patients undergoing either nasolacrimal recanalization (n = 32) or DCR (n = 34) in a tertiary lacrimal disease referral center. Length of surgical duration, clinical outcomes, and rate of recurrence at 18 months postoperatively were compared.The mean surgical duration was 18.5 minutes (range, 15-25 minutes) for nasolacrimal recanalization and 48.2 minutes (range, 45-61 minutes) for DCR, respectively (P < 0.001). The rate of success was 84.4% in the recanalization group and 85.3% in the DCR group, respectively (P = 0.91). The time to recurrence was 2.6 ± 1.1 months in the recanalization group and 5.6 ± 2.1 months in the DCR group (P < 0.001). Five failed cases in each group received a secondary DCR surgery with the same resolution rate (40%). The absence of ocular discharge at baseline was a significant predictor for a successful outcome in the recanalization group (P = 0.04) but not in the DCR group (P = 0.63).Nasolacrimal recanalization is an effective, safe, and time-saving alternative to DCR for the treatment of failed nasolacrimal duct intubation. Clinicians should be cautious in patients with discharge.

  19. Infant with nasolacrimal sinonasal myxoma: Difusion MRI features

    Directory of Open Access Journals (Sweden)

    Teresa Gross Kelly, MD

    2015-01-01

    Full Text Available We report the imaging features of a rare sinonasal myxoma situated over the right nasolacrimal duct in a 5-month-old male. We emphasize the importance of including sinonasal myxomas in the list of differential diagnostic possibilities when encountering a nasolacrimal gland mass in an infant, and describe the CT and MRI characteristics of this rare entity.

  20. High modulus biodegradable polyurethanes for applications in cardiovascular stents: Evaluation of in-vitro degradation and cell viability

    Directory of Open Access Journals (Sweden)

    Melissa eSagarito

    2015-05-01

    Full Text Available We have recently reported the mechanical properties and hydrolytic degradation behaviour of a series of NovoSorb™ [1] biodegradable polyurethanes (PUs prepared by varying the hard segment (HS weight percentage from 60-100. In this study the in-vitro degradation behaviour of the PUs with and without extracellular matrix (ECM coating was investigated under accelerated hydrolytic degradation (phosphate buffer saline; PBS/70°C conditions to allow complete degradation. The mass loss at different time intervals and the effect of aqueous degradation products on the viability and growth of Human Umbilical Vein Endothelial Cells (HUVEC were examined.The results showed that for most PUs in the series the degradation medium turned acidic and the extent of this was dependent on the HS percentage. As the HS decreased, a drop in pH was observed, suggesting that the by-products of soft segment (SS degradation causing the solution to be acidic. Most of the samples were completely eroded by 18 weeks, except PU containing more than 70% HS which only showed partial degradation with no significant change in appearance. The cytotoxicity tests on HUVEC cells of the aqueous extracts obtained after 18 weeks incubation showed that toxicity was dependent on 3 factors: dose, percentage of HS and degradation time. HUVEC growth is similar to but not identical to that observed with tissue culture polystyrene (TCPS standard. The results from this in-vitro cytotoxicity study suggest that the mixture of degradation products formed during the accelerated degradation of this PU series are not toxic to cells under the experimental conditions used.

  1. Treatment of infants with congenital nasolacrimal duct obstruction

    Directory of Open Access Journals (Sweden)

    Zhuo Chen

    2014-07-01

    Full Text Available AIM: To explore the different ages of congenital nasolacrimal duct obstruction in infants, take different treatment methods at different times. METHODS:The 87 cases of 102 children were divided into three different age groups: the first group of 25d-3mo of age 21 cases 26 eyes; The second group >3mo-7mo 31 cases 36 eyes; The third group >7-24mo of age 35 cases 40 eyes. For the first group of infants, the implementation of the lacrimal sac nasolacrimal duct massage + eye drops; for the second group of infants, carry lacrimal pressure washing treatment; for the third group of infants, the implementation of the nasolacrimal duct probing treatment. RESULTS:The first group of children through the nasolacrimal duct sac massage + drops tobramycin eye drops treatment unobstructed 12, the cure rate was 46.2%; The second group of children through pressurized irrigation treatment lacrimal patency by 33, the cure rate was 91.7%; The third group of children through the nasolacrimal duct probing unobstructed 36 treatment, the cure rate was 90.0%. The second and third group were better than the first group(χ2=15.71, Pχ2=15.27, Pχ2=0.02, P>0.05.CONCLUSION:Infants with congenital nasolacrimal duct obstruction should distinguish between ages, taking different treatments, in order to obtain a better therapeutic effect, and lacrimal pressure washing is the preferred way of treating infants with congenital nasolacrimal duct obstruction.

  2. CT evaluation of nasolacrimal relapse of nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Ching, A.S.C. E-mail: chingsc@ha.org.hk; Chong, V.F.H.; Khoo, J.B.K

    2003-08-01

    AIM: The aim of the current study was to elucidate the anatomy of the nasolacrimal apparatus using computed tomography (CT), and to investigate the CT findings suggestive of recurrent nasopharyngeal carcinoma (NPC) involving the nasolacrimal apparatus. MATERIALS AND METHODS: CT images of five patients with clinical or radiological findings suggestive of recurrent NPC who presented with nasolacrimal involvement were reviewed. Involvement of the lacrimal fossa, nasolacrimal canal (NLC), and adjacent anatomic structures including orbit and sinonasal cavities were noted. RESULTS: CT in all patients demonstrated findings of NLC invasion and ostiomeatal complex obliteration. Four of the five patients showed medial canthal mass or pre-septal thickening, ethmoid bulla opacification and inferior nasal meatal involvement. CONCLUSION: Knowledge of the anatomy of the nasolacrimal apparatus using CT is critical for evaluating images for tumour recurrence at this site. NLC invasion, a medial canthal mass and pre-septal thickening are important primary indicators for potential involvement of the nasolacrimal apparatus by recurrent NPC. Secondary signs suggesting this distinct form of relapse are obliteration of ostiomeatal channel, ethmoid bulla opacification and inferior nasal meatus involvement.

  3. Prevalence of amblyopia risk factors in congenital nasolacrimal duct obstruction.

    Science.gov (United States)

    Matta, Noelle S; Singman, Eric L; Silbert, David I

    2010-10-01

    To determine whether children who present to an ophthalmology practice for nasolacrimal duct obstruction are more likely to have risk factors for amblyopia. A retrospective chart review was conducted on all patients presenting to a pediatric oculoplastic specialist between January 1, 2001, and August 8, 2009. The review yielded 402 pediatric patients diagnosed with nasolacrimal duct obstruction. Children were classified as having amblyopia risk factors on the basis of the American Association for Pediatric Ophthalmology and Strabismus referral criteria. Of 402 patients with nasolacrimal duct obstruction, 100% received a cyclopegic refraction. Of these, 88 patients (22%) were found to have amblyogenic risk factors; 65 of these patients had amblyogenic refractive errors, 9 had strabismus, and 14 had a combination of the two. Of the 88 patients with amblyopia risk factors, 11% had a family history of strabismus compared with 9% of patients without amblyopia risk factors, which was not a statistically significant difference. There was no other significant pathology found on the dilated fundus examinations except for one child known to have persistent hyperplastic primary vitreous and a congenital cataract and one child with previously known CHARGE syndrome before the examination for nasolacrimal duct obstruction. Children who present with nasolacromal duct obstructions seem to be more likely to have amblyopia risk factors and therefore should have a full comprehensive pediatric ophthalmological examination, including cycloplegic refraction. Copyright © 2010 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  4. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Park, Hyungkeun

    2006-01-01

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8±42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  5. A rare cause of nasolacrimal duct obstruction: Dentigerous cyst in the maxillary sinus

    Directory of Open Access Journals (Sweden)

    Ray Biswarup

    2009-01-01

    Full Text Available The most common abnormality of the lacrimal drainage system is congenital or acquired nasolacrimal duct obstruction. The causes of acquired nasolacrimal duct obstruction may be primary or secondary. The secondary acquired obstructions may result from infection, inflammation, neoplasm, trauma or mechanical causes. The maxillary sinus cysts usually obstruct the nasolacrimal duct mechanically. Dentigerous cysts are one of the main types of maxillary cysts. These cysts are benign odontogenic cysts which are associated with the crowns of unerupted teeth. The clinical documentations of mechanical nasolacrimal duct obstructions due to a dentigerous cyst in the maxillary sinus are very rare in literature. In this case report, we describe a dentigerous cyst with a supernumerary tooth in the maxillary sinus in an 11-year-old male child causing an obstruction to the nasolacrimal duct. The case was successfully managed surgically by Caldwell Luc approach.

  6. [Anatomy and physiology of the nasolacrimal ducts].

    Science.gov (United States)

    Paulsen, F; Garreis, F; Schicht, M; Bräuer, L; Ali, M J; Sel, S

    2016-06-01

    Ophthalmologists and interventional radiologists are not the only professionals for whom diseases of the efferent tear duct system occupy centre stage; this applies also to ENT specialists involving endonasal conservative or surgical treatment. On the basis of current knowledge and taking account of results yielded by own research in recent years and of clinical aspects, we here give an overview of basic knowledge on the anatomy and physiology of the nasolacrimal system. In doing so functional aspects regarding tear transport as well as embryological and pathophysiological issues are integrated.

  7. Malignant duodenal obstructions: palliative treatment with covered expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Chul; Jung, Gyoo Sik; Lee, Sang Hee; Kim, Sung Min; Oh, Kyung Seung; Huh, Jin Do; Cho, Young Duk [College of Medicine, Kosin Univ, Pusan (Korea, Republic of); Song, Ho Young [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2002-04-01

    To evaluate the feasibility and clinical effectiveness of using a polyurethane-covered expandable nitinol stent in the palliative treatment of malignant duodenal obstruction. Under fluoroscopic guidance, a polyurethane-covered expandable nitinol stent was placed in 12 consecutive patients with malignant duodenal obstructions. All presented with severe nausea and recurrent vomiting. The underlying causes of obstruction were duodenal carcinoma (n=4), pancreatic carcinoma (n=4), gall bladder carcinoma (n=2), distal CBD carcinoma (n=1), and uterine cervical carcinoma (n=1). The sites of obstruction were part I (n=1), part II (n=8), and III (n=3). Due to pre-existing jaundice, eight patients with part II obstructions underwent biliary decompression prior to stent placement. An introducer sheath with a 6-mm outer diameter and stents 16 mm in diameter were employed, and to place the stent, and after-loading technique was used. Stent placement was technically successful in ten patients, and no procedural complications occuured. In one of two patients in whom there was technical failure, and in whom the obstructions were located in part III, the stent was placed transgastrically. Stent migration occurred in one patient four days after the procedure, and treatment involved the palcement of a second, uncovered, nitinol stent. After stent placement, symptoms improved in all patients. During follow-up, obstructive symptoms due to stent stenosis (n=1), colonic obstruction (n=1), and multiple small bowel obstruction (n=1) recurred in three patients. Two of these were treated by placing additional stents in the duodenum and colon, respectively. One of the eight patients in whom a stent was placed in the second portion of the duodenum developed jaundice. The patients died a mean 14 (median, 9) weeks after stent placement. The placement of a polyurethane-covered expandable nitinol stent seems to be technically feasible, safe and effective for the palliative treatment of malignant

  8. Tratamento das obstruções congênitas do ducto nasolacrimal Management of congenital nasolacrimal duct obstruction

    Directory of Open Access Journals (Sweden)

    Epaminondas Castelo Branco Neto

    2009-02-01

    Full Text Available OBJETIVO: Apresentar os resultados do tratamento da obstrução nasolacrimal congênita com a massagem hidrostática de Crigler. MÉTODOS: Cento e oitenta e seis crianças com idade de até 32 meses com obstrução nasolacrimal congênita foram estudadas retrospectivamente de 1990 a 2005. O procedimento foi repetido três vezes em cada sessão, com intervalo de uma semana entre as sessões. A análise foi realizada com o programa informatizado EPI INFO versão 6.04. A signific��ncia estatística foi avaliada pela aplicação dos testes do qui-quadrado e Kruskal-Wallis. RESULTADOS: A faixa de idade predominante nos dois sexos foi de 1 a 5 meses (56,4%, a localização foi bilateral em 36,3%, do lado direito em 34,1% e do lado esquerdo em 29,6%. A epífora estava presente em 100% dos casos e secreção em 56,5%. Curaram com uma sessão 43,6% dos casos, com duas 23,3%, com três 17,4% e com 4 e 5 ou mais sessões 5,8% e 9,0% dos pacientes, respectivamente. Os 14 pacientes que não responderam a massagem foram tratados com sondagem. CONCLUSÃO: A massagem hidrostática de Crigler é efetiva para a obstrução nasolacrimal congênita.PURPOSE: To present the success rate in treating congenital nasolacrimal duct obstruction with hydrostatic pressure (Crigler method. METHODS: Clinical data from 186 children aged up to 32 months treated from 1990 until 2005 were reviewed retrospectively. The procedure was repeated up to 3 times at a one week interval. Using EPI INFO version 6.04 software for analysis, data were tabulated and statistical significance was evaluated by applying chi-square and Kruskal-Wallis tests. RESULTS: Leading age group was 1 to 5 months old (56.4% for males and females. Affection was bilateral in 36.3%, 34.1% on right side and 29.6% on the left side. All cases had epiphora and 56.5% presented mucopurulent discharge. Cure was achieved with one massage for 43.6%, 23.3% with two, 17.4% with three and, with 4 and 5+ sessions in

  9. A Symptom Survey and Quality of Life Questionnaire for Nasolacrimal Duct Obstruction in Children

    Science.gov (United States)

    Holmes, Jonathan M.; Leske, David A.; Cole, Stephen R.; Chandler, Danielle L.; Repka, Michael X.; Silbert, David I.; Tien, David Robbins; Bradley, Elizabeth A.; Sala, Nicholas A.; Levin, Erika M.; Hoover, Darron L.; Klimek, Deborah L.; Mohney, Brian G.; Laby, Daniel M.; Lee, Katherine A.; Enzenauer, Robert W.; Bacal, Darron A.; Mills, Monte D.; Beck, Roy W.

    2008-01-01

    Purpose To develop and validate a new parental questionnaire addressing symptoms and health related quality of life (HRQL) in congenital nasolacrimal duct obstruction (NLDO). Design Cross-sectional study. Participants Children aged 6 to studies of NLDO PMID:16828516

  10. Prevalence of amblyopia in children undergoing nasolacrimal duct irrigation and probing

    OpenAIRE

    Ozgur, Ozlen Rodop; Sayman, Isıl Bahar; Oral, Yesim; Akmaz, Berkay

    2013-01-01

    Purpose: To investigate ambylopia and amblyopia risk factors of children who underwent nasolacrimal duct (NLD) irrigation and probing for congenital nasolacrimal duct obstruction (CNLDO). Materials and Methods: The medical records of patients who had undergone NLD irrigation and probing for CNLDO at an age of 3 years or younger were reviewed, and 51 of the patients were recalled between October 1 and December 31, 2011 for a detailed ophthalmic examination to determinate amblyopia or amblyopia...

  11. Magnetizable stent-grafts enable endothelial cell capture

    Energy Technology Data Exchange (ETDEWEB)

    Tefft, Brandon J. [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Uthamaraj, Susheil [Division of Engineering, Mayo Clinic, Rochester, MN (United States); Harburn, J. Jonathan [School of Medicine, Pharmacy and Health, Durham University, Stockton-on-Tees (United Kingdom); Hlinomaz, Ota [Department of Cardioangiology, St. Anne' s University Hospital, Brno (Czech Republic); Lerman, Amir [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Dragomir-Daescu, Dan [Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN (United States); Sandhu, Gurpreet S., E-mail: sandhu.gurpreet@mayo.edu [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States)

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance. - Highlights: • Magnetic stent-grafts were made from 2205 steel stents and polyurethane nanofibers. • Stent-grafts remained patent and formed a thin and uniform neointima when implanted. • Stent-grafts captured endothelial cells labeled with magnetic nanoparticles.

  12. Continuous Positive Airway Pressure Thresholds for Nasolacrimal Air Regurgitation in a Cadaveric Model.

    Science.gov (United States)

    Blandford, Alexander D; Cherfan, Daniel G; Drake, Richard L; McBride, Jennifer M; Hwang, Catherine J; Perry, Julian D; Cheng, Olivia T

    2018-01-10

    To elucidate the mechanisms underlying nasolacrimal air regurgitation (AR) in the setting of continuous positive airway pressure therapy. Twelve nasolacrimal systems of 6 fresh female human cadavers were evaluated individually for AR using continuous positive airway pressure therapy before any nasolacrimal procedure. Cadavers were then randomly assigned to undergo nasolacrimal duct probing or endoscopic dacryocystorhinostomy and then each hemisystem was again evaluated for AR. The pressure where AR was first observed (discovery pressure) or maximum possible pressure in systems without AR was recorded. In systems that demonstrated AR, the pressure was then gradually decreased to the lowest pressure where regurgitation persisted. This pressure was recorded as the secondary threshold pressure. None of the 12 unoperated nasolacrimal systems or the 6 systems that underwent nasolacrimal duct probing demonstrated AR through the maximum continuous positive airway pressure therapy (30 cm H2O). After endoscopic dacryocystorhinostomy, all 6 nasolacrimal systems demonstrated AR. The mean discovery pressure was 16.0 cm H2O (range, 14.0-18.0 cm H2O) and mean secondary threshold pressure was 7.25 cm H2O (range, 6.5-8.0 cm H2O). Air regurgitation during continuous positive airway pressure therapy in the setting of prior endoscopic dacryocystorhinostomy can be replicated in a cadaver model. The secondary threshold pressures required for AR in this model were similar to AR pressures reported clinically. Prior to dacryocystorhinostomy, patients using continuous positive airway pressure therapy should be counseled on AR, and physicians should consider this phenomenon when evaluating ophthalmic complaints in postoperative patients on positive airway pressure therapy.

  13. Bronchial stents

    Directory of Open Access Journals (Sweden)

    Ibrahim Emad

    2006-01-01

    Full Text Available Bronchial stents are mostly used as a Palliative relief of symptoms often caused by airway obstruction, It is also used for sealing of stump fistulas after pneumonectomy and dehiscence after bronchoplastic operations. Advances in airway prosthetics have provided a variety of silicone stents, expandable metal stents, and pneumatic dilators, enabling the correction of increasingly complex anatomical problems. Several series have been published describing the application and results of these techniques. This manuscript reviews the historical development of stents, types, indication, outcome, and complications. Alternative therapies for tracheobronchial stenting were also reviewed

  14. Towards Individualized Tracheobronchial Stents: Technical, Practical and Legal Considerations.

    Science.gov (United States)

    Freitag, Lutz; Gördes, Martin; Zarogoulidis, Paul; Darwiche, Kaid; Franzen, Daniel; Funke, Faustina; Hohenforst-Schmidt, Wolfgang; Dutau, Hervé

    2017-01-01

    Stent placement has been established as a standard procedure for treating airway obstructions. Other indications are localized malacias and fistulas. Though many different stents with various diameters and lengths are available, the shapes are hardly ever ideal because of the distorted anatomy in patients with diseased airways. There are technical and legal limitations for customizing purchased airway stents. Individually tailored stents would be preferable. New techniques of additive manufacturing such as 3D printing make it possible to produce optimized stents for a particular patient. Using CT data and bronchoscopic images, stents can be constructed that match a particular anatomical situation and apply the optimized expansion force. We give an overview of the currently available manufacturing techniques for polymeric stents and report about our own experience. Direct on-site printing of polyurethane stents in a hospital and printing individual extrusion molds for silicone stents in a certified cleanroom are both feasible. Furthermore, there are promising attempts of combining mechanically customized stents with surface modifications, drug-eluting features, biodegradability, and time-dependent adaptation (4D printing). Truly optimized airway stents with the potential of solving the well-known stent problems such as granulation tissue formation, remodeling, mucostasis, and infections are in reach. The technical hurdles are probably easier to overcome than the legal constraints. The legal situations are discussed from a physician's and a manufacturer's perspective. © 2017 S. Karger AG, Basel.

  15. Microbiologic, radiographic, and anatomic study of the nasolacrimal duct apparatus in the rabbit (Oryctolagus cuniculas)

    International Nuclear Information System (INIS)

    Marini, R.P.; Foltz, C.J.; Kersten, D.; Batchelder, M.; Kaser, W.; Li, X.

    1996-01-01

    This study was motivated by the sporadic observation of epiphora in two male rabbits. The epiphora was unilateral and not associated with conjunctivitis or Pasteurella infection. To characterize the cause of epiphora, we studied 15 specific-pathogen-free New Zealand White rabbits. This study group was composed of the two affected males, four unaffected males, and nine unaffected females. Clinical evaluation consisted of bacterial culture of conjunctival specimens, examination of conjunctival scrapings for chlamydial inclusions, culture and cytologic examination of specimens from the nasolacrimal duct, plain and contrast radiography, latex casting, histologic examination, and the Schirmer tear test. Important differences found in the rabbits with epiphora included an opalescent, gritty, nasolacrimal duct flush fluid and marked unilateral dilatation of the duct proximal to a dorsal flexure at the caudal limit of the incisor tooth root. The flush solution from one affected rabbit cleared with ether, suggesting the presence of triglycerides or cholesterol. The organisms most commonly isolated from the conjunctiva were Moraxella sp., Oligella urethralis, Staphylococcus aureus, coagulase-negative Staphylococcus sp., and Streptococcus viridans. The organisms most commonly isolated from the nasolacrimal duct flush fluid were Moraxella sp., S. viridans, and Neisseria sp. Culture of the nasolacrimal duct flush fluid yielded microorganisms more consistently than did culture of the conjunctival specimens. All microorganisms isolated from affected rabbits also were isolated from unaffected rabbits. There was no apparent contribution of microorganisms to the development of epiphora, and Schirmer tear test results for affected animals were within the range seen in unaffected animals. Occlusion of the nasolacrimal duct was presumed to be attributable to fat droplets nasolacrimal duct anatomic

  16. Temporary urethral covered stent - third year of experience

    International Nuclear Information System (INIS)

    Stojanovis, V.; Maksimovis, H.; Markovis, B.; Markovis, Z.

    2006-01-01

    Full text: In October 2003, a new generation of urethral stents ALLIUM, produced in Israel, were used at the Department of Interventional Radiology, CCS, in 18 patients with chronic stricture of bulbar urethra. The indications for insertion were determined according to well-known and recognized therapeutical protocols. The stent is made of nitinol wire with polyurethane cover. It is inserted under local anesthesia by a special self-expandable system that may be fixed or flexible. The stents we used were 3-6 cm long and 28 Fr wide. Radioscopic-assisted insertion was performed over formerly placed metal guide. Prior to insertion, balloon-catheter dilatation of stricture matching the stent width was carried out. Pre-insertion urethrotomy was performed in one case. The insertion technique is simple, presupposing the knowledge of older generations of techniques of urethral dilatation and insertion of self-expandable stents. The follow-up of results was done according to a priori established protocol including the following: UCG, uroflowmetry and interview with patients. Due to stent migration, the 'stent over stent' technique was applied in one case, while reposition by balloon-catheter outward traction was performed in two cases of caudal migration. No irritative discomforts were reported in the first 4 months after stent dwelling. Uroflowmetric controls verified at least four times better results than before the insertion. Given it is the question of covered stent, there is no possibility of proliferative secondary lumen obstruction. On account of soft structure and conic shape of posterior part of stent, no lesions of the external urethral sphincter were manifested. The stent is simply withdrawn after 6 months by outward traction using the forceps at the time when the stent construction turns into soft and straight wire. The first clinical experiences are very favorable and ALLIUM stent may be expected to be the stent of choice for chronic bulbar strictures

  17. Nasolacrimal obstruction caused by root abscess of the upper canine in a cat.

    Science.gov (United States)

    Anthony, James M G; Sandmeyer, Lynne S; Laycock, Amanda R

    2010-03-01

    A 10-year-old, castrated male domestic short hair cat was presented to the Small Animal Clinic at the Western College of Veterinary Medicine with a presenting complaint of chronic, ocular discharge from the left eye. Ocular examination confirmed epiphora and mucopurulent discharge but there were no apparent reasons for the ocular discharge, and nasolacrimal obstruction was suspected. The cat had swelling of the left side of the face, severe periodontal disease and a fractured upper left canine tooth with pulpal exposure. Dacryocystorhinography revealed narrowing of the nasolacrimal duct above the root of the fractured upper left canine and dental radiographs showed a severe periapical lucency at the apex of the upper left canine tooth. The fractured canine tooth was removed. Subsequently, the ocular discharge and facial swelling resolved. After 2 years, the epiphora has never reoccurred. This is a noteworthy case because a suspected root abscess resulted in extralumenal compression of the nasolacrimal duct, which shows the importance of a thorough oral examination when nasolacrimal obstruction is evident.

  18. Androgen receptor-positive ductal adenocarcinoma of the nasolacrimal duct: A case report

    Directory of Open Access Journals (Sweden)

    In Ah Park

    2017-04-01

    Conclusions and importance: We concluded that this is the first case of AR-positive ductal adenocarcinoma arising from nasolacrimal duct. It is possible that some of the previously documented oncocytic carcinomas of the lacrimal drainage system may include ductal adenocarcinomas with oncocytic features.

  19. Recanalização do ducto nasolacrimal com radiofrequência: estudo preliminar Recanalization of nasolacrimal duct with radio frequency: preliminary study

    Directory of Open Access Journals (Sweden)

    Eduardo Alonso Garcia

    2012-12-01

    Full Text Available OBJETIVO: Avaliar a reconstituição do ducto nasolacrimal com o uso de radiofrequência para restabelecimento do fluxo lacrimal nos casos de obstrução da via lacrimal excretora. MÉTODOS: O procedimento foi realizado em 16 olhos de 16 pacientes (13 femininos e 3 masculinos pelo mesmo cirurgião, utilizando aparelho de radiofrequência monopolar de 450 kHz e 150 W de potência, com anestesia local sob sedação. Os critérios de inclusão foram obstrução baixa da via lacrimal (confirmada por dacriocistografia e idade superior a 18 anos. Os critérios de exclusão foram trauma prévio, dacriocistite aguda, fístula cutânea, mucocele, cirurgia prévia da via lacrimal e uso de marca-passo cardíaco. RESULTADOS: O seguimento mínimo foi de 120 dias, os pacientes realizaram retornos ambulatoriais para avaliação clínica (presença de epífora, secreção, refluxo à expressão do saco lacrimal, posicionamento do tubo de silicone e teste de Milder. Aos 90 dias de pós-operatório, 13 pacientes apresentavam irrigação positiva (81,25% com desobstrução do ducto nasolacrimal e 3 casos (18,75% de insucesso com irrigação impossibilitada (sem passagem para cavidade nasal. CONCLUSÃO: A reconstituição do ducto nasolacrimal com radiofrequência mostrou-se eficaz no tratamento da obstrução da via lacrimal excretora.PURPOSE: To evaluate the nasolacrimal duct reconstitution with radio frequency for restoration of lacrimal flow in cases of nasolacrimal duct obstruction. METHODS: The procedure was carried out in 16 eyes of 16 patients (13 women and 3 men by the same surgeon, with monopolar high-frequency device at 450 kHz and 150 W, with local anesthesia under sedation. Inclusion criteria were lower lacrimal system obstruction (confirmed by dacryocystogram and age over 18 years old. Exclusion criteria were previous trauma, acute dacryocystitis, cutaneous fistula, mucocele, previous lacrimal surgery and cardiac pacemaker. RESULTS: Patients were

  20. Szycher's handbook of polyurethanes

    National Research Council Canada - National Science Library

    Szycher, M

    2013-01-01

    .... Filled with tables, charts, and photographs, it includes new data on green polyurethanes, automotive applications, new coatings, new manufacturing equipment, new health-care uses, and other topics...

  1. Research of Customized Aortic Stent Graft Manufacture

    Science.gov (United States)

    Zhang, Lei; Chen, Xin; Liu, Muhan

    2017-03-01

    Thoracic descending aorta diseases include aortic dissection and aortic aneurysm, of which the natural mortality rate is extremely high. At present, endovascular aneurysm repair (EVAR) has been widely used as an effective means for the treatment of descending aortic disease. Most of the existing coating stents are standard design, which are unable to meet the size or structure of different patients. As a result, failure of treatment would be caused by dimensional discrepancy between stent and vessels, which could lead to internal leakage or rupture of blood vessels. Therefore, based on rapid prototyping sacrificial core - coating forming (RPSC-CF), a customized aortic stent graft manufactured technique has been proposed in this study. The aortic stent graft consists of film and metallic stent, so polyether polyurethane (PU) and nickel-titanium (NiTi) shape memory alloy with good biocompatibility were chosen. To minimum film thickness without degrading performance, effect of different dip coating conditions on the thickness of film were studied. To make the NiTi alloy exhibit super-elasticity at body temperature (37°C), influence of different heat treatment conditions on austenite transformation temperature (Af) and mechanical properties were studied. The results show that the customized stent grafts could meet the demand of personalized therapy, and have good performance in blasting pressure and radial support force, laying the foundation for further animal experiment and clinical experiment.

  2. Endoscopic treatment of nasolacrimal sac obstruction secondary to fibrous dysplasia of paranasal sinuses.

    Science.gov (United States)

    Zodpe, Prakash; Chung, Seung-Won; Kang, Hee Joon; Lee, Sang Hag; Lee, Heung-Man

    2007-05-01

    Fibrous dysplasia involving paranasal sinuses mostly has asymptomatic features, but sometimes may cause signs and symptoms which relate to the location and extent of bony abnormalities. The use of endoscopic nasal surgery for debulking ethmoidal fibrous dysplasia, blocking the left nasolacrimal sac and simultaneous intranasal endoscopic dacryocystorhinostomy with silicone intubation is presented. The procedure and advantages of endoscopic approach over the external approach are outlined in this paper.

  3. Gastrointestinal stenting

    International Nuclear Information System (INIS)

    Zollikofer, C.L.; Schoch, E.; Jost, R.; Decurtins, M.

    2000-01-01

    Acute obstructions of the gastric outlet, the duodenum, or the large bowel require rapid treatment to relieve symptoms of retention or ileus. Large-caliber stents of 16 to 22 mm offer a new non-surgical alternative for treating these patients with minimal risks and high success rates. For gastroduodenal outlet obstructions palliated by self-expanded metal stents, clinical success rates are in the range of 80-100 %. Preoperative treatment of colorectal obstructions successfully relieves acute symptoms of ileus in 87-100 % allowing primary anastomosis and thereby reducing the costs caused by multiple operations and the need of intensive care by approximately 25 %. It is the purpose of this review to familiarize the reader with the indications, possibilities, and limits of intestinal stenting. (orig.)

  4. Fabrication and In Vitro Deployment of a Laser-Activated Shape Memory Polymer Vascular Stent

    Energy Technology Data Exchange (ETDEWEB)

    Baer, G M; Small IV, W; Wilson, T S; Benett, W J; Matthews, D L; Hartman, J; Maitland, D J

    2007-04-25

    Vascular stents are small tubular scaffolds used in the treatment of arterial stenosis (narrowing of the vessel). Most vascular stents are metallic and are deployed either by balloon expansion or by self-expansion. A shape memory polymer (SMP) stent may enhance flexibility, compliance, and drug elution compared to its current metallic counterparts. The purpose of this study was to describe the fabrication of a laser-activated SMP stent and demonstrate photothermal expansion of the stent in an in vitro artery model. A novel SMP stent was fabricated from thermoplastic polyurethane. A solid SMP tube formed by dip coating a stainless steel pin was laser-etched to create the mesh pattern of the finished stent. The stent was crimped over a fiber-optic cylindrical light diffuser coupled to an infrared diode laser. Photothermal actuation of the stent was performed in a water-filled mock artery. At a physiological flow rate, the stent did not fully expand at the maximum laser power (8.6 W) due to convective cooling. However, under zero flow, simulating the technique of endovascular flow occlusion, complete laser actuation was achieved in the mock artery at a laser power of {approx}8 W. We have shown the design and fabrication of an SMP stent and a means of light delivery for photothermal actuation. Though further studies are required to optimize the device and assess thermal tissue damage, photothermal actuation of the SMP stent was demonstrated.

  5. Szycher's handbook of polyurethanes

    National Research Council Canada - National Science Library

    Szycher, M

    2013-01-01

    "Written as a reference for polyurethane technologists and end users, raw materials suppliers, and students in the field, this second edition covers the technical advances in the field over the past 10 years...

  6. Polyurethane-Foam Maskant

    Science.gov (United States)

    Bodemeijer, R.

    1985-01-01

    Brown wax previously used to mask hardware replaced with polyurethane foam in electroplating and electroforming operations. Foam easier to apply and remove than wax and does not contaminate electrolytes.

  7. Angioplasty and Vascular Stenting

    Science.gov (United States)

    ... vessel. Covered stents or stent-grafts have additional advantages over bare stents and are becoming more commonly ... us improve RadiologyInfo.org by taking our brief survey: Survey Do you have a personal story about ...

  8. Upper Gastrointestinal Stent

    OpenAIRE

    Kim, Sang Gyun; Yang, Chang-Hun

    2012-01-01

    Gastrointestinal (GI) stent has been developed for palliation of obstructive symptoms in various diseases causing obstruction of GI tract. Self-expanding metal stent (SEMS) has replaced old type of plastic stent, and endoscopic insertion of stent has replaced fluoroscopy-guided insertion. Nowadays, newly-designed SEMSs have been developed for prevention of complications such as stent migration and re-obstruction, and indications of stent recently have been widened into benign conditions as we...

  9. Symptomatic stent cast.

    LENUS (Irish Health Repository)

    Keohane, John

    2012-02-03

    Biliary stent occlusion is a major complication of endoscopic stent insertion and results in repeat procedures. Various theories as to the etiology have been proposed, the most frequently studied is the attachment of gram negative bacteria within the stent. Several studies have shown prolongation of stent patency with antibiotic prophylaxis. We report the case of stent occlusion from a cast of a previously inserted straight biliary stent; a "stent cast" in an 86-year-old woman with obstructive jaundice. This was retrieved with the lithotrypter and she made an uneventful recovery. This is the first reported case of a biliary stent cast.

  10. Mechanisms of biliary stent clogging: confocal laser scanning and scanning electron microscopy.

    Science.gov (United States)

    van Berkel, A M; van Marle, J; Groen, A K; Bruno, M J

    2005-08-01

    Endoscopic insertion of plastic biliary endoprostheses is a well-established treatment for obstructive jaundice. The major limitation of this technique is late stent occlusion. In order to compare events involved in biliary stent clogging and identify the distribution of bacteria in unblocked stents, confocal laser scanning (CLS) and scanning electron microscopy (SEM) were carried out on two different stent materials - polyethylene (PE) and hydrophilic polymer-coated polyurethane (HCPC). Ten consecutive patients with postoperative benign biliary strictures were included in the study. Two 10-Fr stents 9 cm in length, one made of PE and the other of HCPC, were inserted. The stents were electively exchanged after 3 months and examined using CLS and SEM. No differences were seen between the two types of stent. The inner stent surface was covered with a uniform amorphous layer. On top of this layer, a biofilm of living and dead bacteria was found, which in most cases was unstructured. The lumen was filled with free-floating colonies of bacteria and crystals, surrounded by mobile laminar structures of mucus. An open network of large dietary fibers was seen in all of the stents. The same clogging events occurred in both PE and HCPC stents. The most remarkable observation was the identification of networks of large dietary fibers, resulting from duodenal reflux, acting as a filter. The build-up of this intraluminal framework of dietary fibers appears to be a major factor contributing to the multifactorial process of stent clogging.

  11. Dual chamber stent prevents organ malperfusion in a model of donation after cardiac death.

    Science.gov (United States)

    Tillman, Bryan W; Chun, Youngjae; Cho, Sung Kwon; Chen, Yanfei; Liang, Nathan; Maul, Timothy; Demetris, Anthony; Gu, Xinzhu; Wagner, William R; Tevar, Amit D

    2016-10-01

    The paradigm for donation after cardiac death subjects donor organs to ischemic injury. A dual-chamber organ perfusion stent would maintain organ perfusion without affecting natural cardiac death. A center lumen allows uninterrupted cardiac blood flow, while an external chamber delivers oxygenated blood to the visceral vessels. A prototype organ perfusion stent was constructed from commercial stents. In a porcine model, the organ perfusion stent was deployed, followed by a simulated agonal period. Oxygenated blood perfused the external stent chamber. Organ perfusion was compared between controls (n = 3) and organ perfusion stent (n = 6). Finally, a custom, nitinol, dual chamber organ perfusion stent was fabricated using a retrievable "petal and stem" design. Endovascular organ perfusion stent deployment achieved visceral isolation without adverse impact on cardiac parameters. Visceral oxygen delivery was 4.8-fold greater compared with controls. During the agonal period, organs in organ perfusion stent-treated animals appeared well perfused in contrast with the malperfused controls. A custom nitinol and polyurethane organ perfusion stent was recaptured easily with simple sheath advancement. An organ perfusion stent maintained organ perfusion during the agonal phase in a porcine model of donation after cardiac death organ donation without adversely affecting cardiac function. Ultimately, the custom retrievable design of this study may help resolve the critical shortage of donor organs for transplant. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Optimum duration of J.J. stenting in live related renal transplantation

    Directory of Open Access Journals (Sweden)

    Balbir S Verma

    2002-01-01

    Full Text Available Purpose: Ureterovesical anastomosis related compli-cations might cause significant morbidity, allograft loss and even mortality. Routine prophylactic JJ stenting against these complications though controversial seems to be gaining literature support. - ′ There is no consensus as to the optimum duration of stenting and various stud-ies report stenting for 1 week to 3 months. This study was conducted to know the optimum duration of JJ stenting in renal transplantation. Material and Methods: 52 (group 1 live related renal transplant recipients, stented for 2 weeks were compared to 57 (group 2 historical controls (from our previous study 5, stented for 4 weeks. A 16 cm/6F polyurethane JJ stent was left across the ureteroneocvstostomy performed by Lich Gregoir technique. The stent was removed under local anesthesia within same admission in group 1 and in second admission in group 2. Both groups received simi-lar antibiotics and bnmunosuppression and were moni-tored for urological complications. Results: There was no major urological complication requiring surgical intervention in either group. The inci-dence of minor complications resolving with conservative management was also similar in the 2 groups. There were 2 ,forgotten stents in group 2 (badly encrusted and removed at 3 years and 11 months respectively. The second ad-mission in group 2 for stent removal incurred extra cost as it was done in the routine operation theatre to avoid infection. Conclusions: Reducing the duration of stenting from 4 weeks to 2 weeks avoids complications associated with pro-longed use of stent without compromising the beneficial ef-′ feats of stent in preventing the urological complications. It obviates the risk of forgotten stent as well as curtails the cost of second admission for stent removal.

  13. Efficacy of a paclitaxel-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt: an experimental study in a swine model

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Oh, Joo Hyeong; Kwon, Se Hwan; Park, Young Koo; Song, Ho Young; Yuk, Sun Hong

    2007-01-01

    To evaluate the efficacy of a paclitaxel-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt. Twelve pigs were used in this study. Two types of 10-mm diameter and 60-mm long nitinol stents were made for a transjugular intrahepatic portosystemic shunt by coating them with a polyurethane solution, with and without paclitaxel. Each transjugular intrahepatic portosystemic shunt was created successfully in the 12 swine with 7 paclitaxel-eluting stents and 5 polyurethane stents. Five swine in each group were followed-up for 14 days due to the death of 2 swine given the paclitaxel-eluting stents. The proliferation of the pseudointima was evaluated on both follow-up portograms and histopathology examinations. The mean maximum pseudointimal hyperplasia is expressed as the percentage of the stent radius. On the portograms, all the transjugular intrahepatic portosystemic shunts using the paclitaxel-eluting stents maintained patency despite there being a complete occlusion of the polyurethane stents in all the animals. The histopathology analysis revealed the mean maximum pseudointimal hyperplasia to be 25% and 76% in the paclitaxel-eluting and control stents, respectively

  14. Success rate of late primary probing in congenital nasolacrimal duct obstruction.

    Science.gov (United States)

    Rajabi, Mohammad Taher; Abrishami, Yalda; Hosseini, Seyedeh Simindokht; Tabatabaee, Syed Ziaeddin; Rajabi, Mohammad Bagher; Hurwitz, Jeffrey J

    2014-01-01

    To investigate the clinical outcomes of late primary probing in congenital nasolacrimal duct (NLD) obstruction. A prospective interventional study was designed to recruit children older than 24 months who presented with clinical manifestations of NLD obstruction since February 2008 to Farabi Eye Hospital, Tehran, Iran. No prior surgical intervention for NLD obstruction was performed on these patients; they underwent probing of the nasolacrimal system and irrigation under general anesthesia by oculoplastic surgeons. The outcome of the procedure was assessed 2 to 3 months postoperatively. Data of the patients until February 2013 were considered for analysis. The total number of patients during the 5-year study was 343. The total success rate considering all of the age groups was 75.8%. The success rate was 85% in those who were 2 to 3 years old, 63% in those who were 3 to 4 years old, and 50% in those who were 4 to 5 years old. In patients with chronic dacryocystitis with mucopurulent discharge, 83% had successful probing and irrigation. In patients with epiphora with no mucopurulent discharge, 59% had successful results with probing. In the cases of congenital NLD obstruction, primary probing before 2 years of age has a high success rate; there is a high overall success rate (75.8%) in the 2- to 5-years age group, but when older than 5 years, further procedures such as intubation and dacryocystorhinostomy would be needed because of the high failure rate of probing. Copyright 2014, SLACK Incorporated.

  15. Naso-lacrimal duct balloon dilatation: Medium to long term follow-up

    International Nuclear Information System (INIS)

    McCullough, K. Mark

    2001-01-01

    AIM: Subjective patient response to nasolacrimal duct balloon dilatation (dacryocystoplasty) for epiphora due to primary acquired nasolacrimal duct obstruction (PANDO), was sought over the medium to long term. The relevant dacryocystograms were reviewed to assess the relationship between treatment outcome and dacryocystographic appearances. MATERIALS AND METHODS: Sixty-three patients who had, in the preceding 12-month to 8-year period, undergone 102 dacryocystoplasties were sent a postal questionnaire in which subjective response to treatment was requested. Fifty-seven original dacryocystograms were reviewed by the author and the appearances of the lacrimal sacs subjectively assessed. RESULTS: The results showed that in 31% of respondents (total response 48/63, 76%) dacryocystoplasty was ineffective for treatment of PANDO. Treatment failures did not respond to repeat treatment. Sixty-nine per cent of patients considered themselves either cured or improved by the treatment, with a minimal relapse rate during the period studied. The original dacryocystoplasty appearances were unhelpful in predicting treatment response. CONCLUSION: Dacryocystoplasty can be expected to relieve or improve epiphora in 69% patients with PANDO, (incomplete obstruction) and favourable response to treatment is durable in the medium to long term. Repeat treatment is not recommended for those who fail to respond, though may be appropriate for cases of temporary response. The technique is safe and well tolerated. McCullough, K.M. (2001). Clinical Radiology 56, 13-16

  16. Biodegradation of polyurethanes; Polyurethane no biseibutsu bunkai

    Energy Technology Data Exchange (ETDEWEB)

    Kinpara, N.; Ando, M.; Ohira, Z. [Suzuki Motor Corp., Shizuoka (Japan); Nakajima, T.; Nakahara, T. [University of Tsukuba, Tsukuba (Japan)

    1997-10-01

    Different types of Polyurethane (PUR) are used for various industrial products and are used in increasing quantities every year. We experimented with biodegradation of PURs to dispose of industrial wastes. 2 strains of fungi and 1 strain of bacteria which were seemed to have the ability to degrade PURs well were isolated from various soils and waste water. These strains could degrade ester-type PUR and PUR made from a mixture of ester and ether. However, these strains could not degrade ether-type PUR. From Scanning Electron Microscopy observation, it is suggested that the microbial degradation proceeded in at least 2 patterns. 4 refs., 8 figs., 2 tabs.

  17. Biocompatibility of a new device of self-expandable covered and non-covered tracheal stent: comparative study in rats

    Directory of Open Access Journals (Sweden)

    Olavo Ribeiro Rodrigues

    2013-01-01

    Full Text Available PURPOSE: To investigate the compatibility of a new model of self-expandable tracheal stent in rats. METHODS: A new device of polyurethane covered and non - covered stent was placed in the trachea of Wistar rats. Animals were distributed in two groups: the polyurethane covered and non-covered group. Macroscopic parameters included position within the tracheal lumen, adherence to the mucosa, degree of dilatation, permeability and internal diameter. Microscopic findings evaluated were: incorporation, inflammatory activity, granulation tissue and epithelial revetment injuries. The observation follow-up was six weeks. All parameters were quantified based on determined score values. Incorporation of the stents was evaluated based on the observation if the stent was fixed into the trachea or if it could be removed. Degree of dilatation was performed by external diameter measurements. Granulation tissue was evaluated by measurements of height of the tissue growing into the tracheal lumen. RESULTS: 100% of non-covered stents had total attachment to mucosa and 100% of polyurethane covered type had adherence only. Regarding dilatation, granulation tissue, inflammatory activity and internal diameter measurements, there were no significant differences between the groups. Pathological tracheal wall injuries were present in both groups. CONCLUSION: Both models of stent demonstrated biocompatibility with the trachea. Rats are suitable for an experimental model of tracheal stent study.

  18. Shape memory polyurethane nanocomposites

    Science.gov (United States)

    Cao, Feina

    Shape memory polymers are smart materials which can remember their original shapes. However, the low recovery stress and low mechanical strength limit the commercial applications of shape memory polymers. In this study, nanoclays were introduced to shape memory polyurethanes (SMPU) to augment these properties by enhance the network of SMPU. Several factors which influence the shape recovery stress were evaluated, including the nature of polymer chain by using different monomers, type of clay particles, extent of filler dispersion, clay content and deformation conditions. It was found that only reactive clay particles were well dispersed into polyurethane matrix by the tethering between --CH2CH 2OH functional groups in clay surfactants and polyurethane chains. Two different shape memory polyurethanes (Systems I & II) prepared by bulk polymerization were compared. The shape memory effect of System I was triggered by melting of the soft segment crystals, while that of System II was by glass transition of the soft segments. It was seen that the reactive clay particles dispersed well in both polyurethane matrices and augmented the recovery stress, e.g., 20% increase with 1 wt % nanoclay in System I and 40% increase with 5 wt % nanoclay in System II were observed. In System I, clay particles interfered with soft segment crystallization, and promoted phase mixing between the hard and soft segments, thus affecting the fixity and recovery ratio. Nevertheless, the soft segment crystallinity was still enough and in some cases increased due to stretching to exhibit excellent shape fixity and shape recovery ratio. The higher loading of clay particles accelerated the stress relaxation, resulting in reduction of recovery stress. In System II, no significant effect of clay particles in phase separation was observed, so there was no influence of clay on shape fixity and recovery ratio. The recovery stress increased with reactive nanoclay content. It was also found that the recovery

  19. Melanorrhea: Noncontiguous spread of palpebral conjunctival melanoma to the nasolacrimal duct

    Directory of Open Access Journals (Sweden)

    Raksha Rao

    2018-01-01

    Full Text Available A 42-year-old Asian Indian male with a history of conjunctival melanoma in the left eye presented with a recurrent tumor in the upper tarsal conjunctiva. The tumor was completely excised under margin control, followed by two-staged eyelid reconstruction. During the second stage of the eyelid reconstruction, a brown-colored discharge was noted at the punctum, which on cytology was confirmatory of melanoma. Left dacryocystectomy with en bloc nasolacrimal duct (NLD excision was performed. Histopathology demonstrated infiltration of the NLD by the tumor with no presence of melanoma in the lacrimal sac. Lacrimal oncorrhea is a term used to describe tumor spread by free-floating cells in the tear film. All conjunctival tumors carry a risk of tumor spread by oncorrhea.

  20. Dacryocystitis following a nasolacrimal duct obstruction caused by an ectopic intranasal tooth in a dog.

    Science.gov (United States)

    Voelter-Ratson, Katrin; Hagen, Regine; Grundmann, Stefan; Spiess, Bernhard Martin

    2015-09-01

    To describe a nasolacrimal duct (NLD) obstruction secondary to an ectopic tooth in a 5-year-old male Border collie. The dog was presented with a 1-month history of mucopurulent discharge from the left eye (OS) preceded by a lifelong history of epiphora OS. Treatment with neomycin/polymyxin B/dexamethasone ophthalmic solution had not improved the clinical signs, and the NLD was not patent when irrigated by the referring veterinarian. A complete ophthalmologic examination was performed followed by dacryocystorhinography and computed tomography (CT). The ophthalmologic examination revealed marked mucopurulent discharge, mild conjunctivitis, slightly elevated STT measurements, and a negative Jones test OS. Both nasolacrimal puncta OS could be cannulated without resistance for approximately 1.5 cm. Upon irrigation, copious amounts of mucopurulent discharge were exited through the corresponding punctum, while no fluid could be detected at the nares. Dacryocystorhinography was performed. Radiographs revealed an ectopic left canine tooth within the left nasal cavity. A cystic dilation of the NLD was observed proximal to the ectopic tooth. Computed tomography was performed to determine the exact position of the tooth and possible involvement of adjacent structures; CT confirmed the previous imaging findings. Treatment with systemic antibiotics, NSAIDs, and ofloxacin ophthalmic solution led to resolution of the clinical signs within several days. Surgery was declined by the owner. This is the first case report describing a blocked NLD due to an ectopic tooth in a dog. Ectopic teeth should be included as a differential diagnosis in cases of dacryocystitis and chronic epiphora in dogs. © 2014 American College of Veterinary Ophthalmologists.

  1. Nasolacrimal duct obstruction: Does it really increase the risk of amblyopia in children?

    Directory of Open Access Journals (Sweden)

    V Akila Ramkumar

    2016-01-01

    Full Text Available Purpose: To report the prevalence of amblyopia risk factors in children with congenital nasolacrimal duct obstruction. Methods: A retrospective review of records of children with the diagnosis of congenital nasolacrimal duct obstruction (NLDO, who underwent probing from January 2009 to October 2011, was done. All of them underwent a complete ophthalmic evaluation including cycloplegic refraction and strabismus evaluation before probing. Results: A total of 142 children were included in this study. The mean age at presentation was 22.38 months (sample standard deviation (SSD - 15.88. Amblyopia risk factors were defined according to two sets of guidelines: The American Association for Pediatric Ophthalmology and Strabismus (AAPOS referral criteria guidelines and the new AAPOS Vision Screening Committee guidelines. Twenty-eight (20% children were found to have some form of amblyopia risk factor based on the referral criteria prescribed by AAPOS. However, on applying modified guidelines described by Donahue et al., to analyze the same cohort, 21 children were found to have amblyogenic risk factors. Of these 28 children, 13 had significant astigmatism (>1.50 D, 8 children had hypermetropia (>3.50 D, and six children had anisometropia (>1.50 D. One child had significant cataract (media opacity >1 mm. None of the children in this series had either myopia or strabismus. Conclusion: Prevalence of amblyopia risk factor was found to be 20% in our study based on the older guidelines; however, it reduces to 14.78% by applying the modified guidelines. Despite this reduction, importance of a comprehensive ophthalmic examination including cycloplegic refraction in all children presenting with NLDO cannot be overstated. A close follow-up of these children is also essential to prevent the development of amblyopia.

  2. The prevalence of amblyogenic factors in children with persistent congenital nasolacrimal duct obstruction.

    Science.gov (United States)

    Eshraghi, Bahram; Akbari, Mohammad Reza; Fard, Masoud Aghsaei; Shahsanaei, Azadeh; Assari, Raheleh; Mirmohammadsadeghi, Arash

    2014-11-01

    To evaluate the prevalence of amblyopia risk factors in children that underwent probing for persistent congenital nasolacrimal duct obstruction (CNLDO). The medical records of children with CNLDO (after 1 year of age) that underwent probing were reviewed. Amblyopia risk factors, based on the American Association for Pediatric Ophthalmology and Strabismus referral criteria in 2013, were sought in the patientsʹ records before probing. The proportion of the patients with anisometropia >1.5 diopters (D) was separately calculated. In unilateral cases of CNLDO, sphere, astigmatism, and spherical equivalent of the eyes with CNLDO were compared with contralateral eyes in order to assess the effect of CNLDO on refractive error. In the follow-up examinations, the success of the probing or the need for additional procedures (Crawford intubation, Monoka intubation, or dacryocystorhinostomy) was evaluated. The prevalence of anisometropia between 'successful probing' and 'failed probing' groups was compared. A total of 433 cases were included in the study. 41 cases (9.46 %) had amblyopia risk factors. Twenty-four cases (5.5 %) had anisometropia >1.5 D (spherical or cylindrical). In unilateral cases of CNLDO, the sphere and spherical equivalent of the eyes with CNLDO were significantly greater than those of the contralateral eyes (p prevalence in this group, compared with the successful probing group, at the initial examination (p = 0.03). The findings of greater prevalence of anisometropia >1.5 D (compared with the prevalence in the general population) and significantly greater sphere and spherical equivalents in the eye with CNLDO (compared with contralateral eye) in unilateral cases with CNLDO, suggested some relationships between anisometropia and long-term untreated CNLDO. The finding of more anisometropia in failed probing cases may support the theory of structural abnormality as an explanation for the possible relationship between congenital nasolacrimal duct

  3. Nasolacrimal duct obstruction: Does it really increase the risk of amblyopia in children?

    Science.gov (United States)

    Ramkumar, V Akila; Agarkar, Sumita; Mukherjee, Bipasha

    2016-07-01

    To report the prevalence of amblyopia risk factors in children with congenital nasolacrimal duct obstruction. A retrospective review of records of children with the diagnosis of congenital nasolacrimal duct obstruction (NLDO), who underwent probing from January 2009 to October 2011, was done. All of them underwent a complete ophthalmic evaluation including cycloplegic refraction and strabismus evaluation before probing. A total of 142 children were included in this study. The mean age at presentation was 22.38 months (sample standard deviation (SSD) - 15.88). Amblyopia risk factors were defined according to two sets of guidelines: The American Association for Pediatric Ophthalmology and Strabismus (AAPOS) referral criteria guidelines and the new AAPOS Vision Screening Committee guidelines. Twenty-eight (20%) children were found to have some form of amblyopia risk factor based on the referral criteria prescribed by AAPOS. However, on applying modified guidelines described by Donahue et al., to analyze the same cohort, 21 children were found to have amblyogenic risk factors. Of these 28 children, 13 had significant astigmatism (>1.50 D), 8 children had hypermetropia (>3.50 D), and six children had anisometropia (>1.50 D). One child had significant cataract (media opacity >1 mm). None of the children in this series had either myopia or strabismus. Prevalence of amblyopia risk factor was found to be 20% in our study based on the older guidelines; however, it reduces to 14.78% by applying the modified guidelines. Despite this reduction, importance of a comprehensive ophthalmic examination including cycloplegic refraction in all children presenting with NLDO cannot be overstated. A close follow-up of these children is also essential to prevent the development of amblyopia.

  4. Prevalence of amblyopia in children undergoing nasolacrimal duct irrigation and probing

    Directory of Open Access Journals (Sweden)

    Ozlen Rodop Ozgur

    2013-01-01

    Full Text Available Purpose: To investigate ambylopia and amblyopia risk factors of children who underwent nasolacrimal duct (NLD irrigation and probing for congenital nasolacrimal duct obstruction (CNLDO. Materials and Methods: The medical records of patients who had undergone NLD irrigation and probing for CNLDO at an age of 3 years or younger were reviewed, and 51 of the patients were recalled between October 1 and December 31, 2011 for a detailed ophthalmic examination to determinate amblyopia or amblyopia risk factors. Amblyopia was accepted as difference in visual acuity of two or more Snellen lines between the two eyes or visual acuity of 20/30 or worse in either eye. Results: The median age of the 51 patients to whom NLD irrigation and probing were attempted for CNLDO was 23 months. CNLDO affected a total of 70 eyes. All patients were reviewed for best-corrected visual acuity, refractive errors, and strabismus at a median age of 70.5 months (range 31-95 months. Amblyopia or amblyopia risk factors were identified in 14 patients (27.5%. One child (7.15% had only strabismus, six children (42.8% had only amblyogenic refractive errors, two (14.3% had a combination of two, one child (7.15% had a family history for amblyopia, but four children (28.6% had no amblyopia risk factors but had amblyopia. Conclusion: Amblyogenic risk factors are found higher in patients with CNLDO and patients undergoing NLD irrigation and probing in comparison to normal population. Therefore, we recommend these children to routinely undergo cycloplegic refractions and full ophthalmic examinations.

  5. Prevalence of amblyopia in children undergoing nasolacrimal duct irrigation and probing.

    Science.gov (United States)

    Ozgur, Ozlen Rodop; Sayman, Isıl Bahar; Oral, Yesim; Akmaz, Berkay

    2013-12-01

    To investigate ambylopia and amblyopia risk factors of children who underwent nasolacrimal duct (NLD) irrigation and probing for congenital nasolacrimal duct obstruction (CNLDO). The medical records of patients who had undergone NLD irrigation and probing for CNLDO at an age of 3 years or younger were reviewed, and 51 of the patients were recalled between October 1 and December 31, 2011 for a detailed ophthalmic examination to determinate amblyopia or amblyopia risk factors. Amblyopia was accepted as difference in visual acuity of two or more Snellen lines between the two eyes or visual acuity of 20/30 or worse in either eye. The median age of the 51 patients to whom NLD irrigation and probing were attempted for CNLDO was 23 months. CNLDO affected a total of 70 eyes. All patients were reviewed for best-corrected visual acuity, refractive errors, and strabismus at a median age of 70.5 months (range 31-95 months). Amblyopia or amblyopia risk factors were identified in 14 patients (27.5%). One child (7.15%) had only strabismus, six children (42.8%) had only amblyogenic refractive errors, two (14.3%) had a combination of two, one child (7.15%) had a family history for amblyopia, but four children (28.6%) had no amblyopia risk factors but had amblyopia. Amblyogenic risk factors are found higher in patients with CNLDO and patients undergoing NLD irrigation and probing in comparison to normal population. Therefore, we recommend these children to routinely undergo cycloplegic refractions and full ophthalmic examinations.

  6. Polyurethanes with radiopaque properties.

    Science.gov (United States)

    James, Nirmala R; Philip, Juby; Jayakrishnan, A

    2006-01-01

    An aliphatic, commercially available, medical grade polyurethane, Tecoflex 80A was made radiopaque by coupling a 5-iodine-containing molecule, N-(2,6- diiodocarboxyphenyl)-3,4,5-triiodo benzamide (DCPTB) onto the polymer backbone. DCPTB was synthesized by coupling 4-amino-3,5-diiodobenzoic acid and 3,4,5-triiodobenzoic acid using dicyclohexyl carbodiimide. Radiopaque polyurethane thus obtained was characterized by IR, TGA, DSC and X-radiography. By optimizing the reaction conditions, it was possible to incorporate about 8% iodine in the polymer (wt/wt) to achieve radiopacity almost equivalent to that of a 2mm thick aluminium wedge. However, the products differed from the starting polymer in thermal characteristics. The starting polymer showed two endothermic transitions, the first one due to glass transition of the soft segment and the second one due to disruption of the hard segments. After modification, the second transition shifted to a lower temperature, while the first transition remained unaltered. Also, the modified polymers showed reduced thermal stability compared to the starting polymer. These observations could be explained on the basis of the reduced extent of intermolecular hydrogen bonding among the hard segments of the end product. Radiopaque polyurethanes are expected to have significant advantage over their non-radiopaque counterparts in many medical and related applications.

  7. Enteral stents.

    Science.gov (United States)

    Varadarajulu, Shyam; Banerjee, Subhas; Barth, Bradley; Desilets, David; Kaul, Vivek; Kethu, Sripathi; Pedrosa, Marcos; Pfau, Patrick; Tokar, Jeffrey; Wang, Amy; Song, Louis-Michel Wong Kee; Rodriguez, Sarah

    2011-09-01

    The American Society for Gastrointestinal Endoscopy (ASGE) Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases, data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through August 2010 for articles related to enteral, esophageal, duodenal, and colonic stents. Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  8. NATURAL FIBER REINFORCED POLYURETHANE RIGID FOAM

    OpenAIRE

    Seydibeyoglu, M.Ozgur; Demiroğlu, Sibel; Erdoğan, Fatma; Akın, Ecem; Ayvalık, Aynur; Karavana, Hüseyin Ata

    2017-01-01

    The main objective of this study was to prepare polyurethane foam reinforced with local Turkish natural resources. In this work, olive kernel and nutshell fibers were used for reinforcing the polyurethane foam. In order to characterize reinforced polyurethane samples, mechanical, chemical, thermal, and morphological methods were used. Mechanical properties of polyurethane foam were measured by compression test. With compression test, it was observed that compressive strength of polyurethane f...

  9. A novel electrical potential sensing method for in vitro stent fracture monitoring and detection.

    Science.gov (United States)

    Park, Chan-Hee; Tijing, Leonard D; Yun, Yeoheung; Kim, Cheol Sang

    2011-01-01

    This article describes a preliminary investigation and prototype fabrication of a novel potential sensing method to continuously monitor vascular stent fractures. A potential measurement system consisting of Wheatstone bridge circuit and signal conditioning circuit was designed for the cardiovascular stent durability and fatigue test. Each end of a bare and polyurethane-covered Nitinol vascular stent was electrically connected to the potential measurement system and then immersed either in simulated body fluid (SBF) media or distilled water at 36.4 ± 1 °C. When the stent experienced fracture (i.e., a cut), its electrical potential decreased with an increase in electrical resistance. This method successfully measured fractures in the stent regardless of location. Furthermore, the number of cycles at the onset of stent fracture was accurately detected and continuously monitored using this technique. Thus, the present fracture detection method, which to our knowledge is the first ever report to use electrical potential measurement for stent durability test, gives a fast, real-time, accurate and efficient detection of fractures in stent during in vitro fatigue and durability test.

  10. Development of radioactive stent using HANARO research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Bae; Kim, J. R.; Han, H. S.; Shin, B. C.; Kim, Y. M.; Cho, U. K.; Han, K. H.; Park, W. W.; Chung, Y. J

    1997-10-01

    Radioactive cylindrical was prepared by neutron irradiation of pre-made non-radioactive `1`6`5 Ho-sleeve, which was made by casting polyurethane solution containing `1`6`5`Ho(NO{sub 3}){sub 3} in THF+DMF (10:1) solvent in cylindrical glass tube. Its length and diameter could be easily controlled by glass tube used as a mold. The radioactive stent assembly (`1`6`5Ho-SA) was prepared by covering the metallic stent with radioactive sleeve and then treated both ends with epoxy glue for prevention of peeling off the radioactive sleeve from stent (post-irradiation method). Other preparation method of radioactive stent is similar to that of the first one except using radioactive `1`6`6Ho(NO{sub 3}){sub 3} and glass tube fitted with metallic stent before casting (pre-irradiation method). Scanning electron microscopy and autoradiography exhibited that the distribution of `1`6`5Ho and `1`6`6Ho(NO{sub 3}) compounds in polyurethane matrix was nearly homogeneous. The present preparation methods of radioactive sleeve and stent are quite different from conventional method which metallic stent is coated or implanted with radionuclide. The ease with which the radioactive stent can be prepared and its homogeneous radiation emission make it an attractive radiation applicator for the treatment of esophagus cancer. As an animal studies, 6 pathologic specimens were obtained. An animal with 4 mCi of `1`6`6Ho-SA showed loss of epithelial tissue and inflammation at the submucosal layer 4 weeks after the procedure. Considerable improvement of the inflammatory reaction was observed 7 weeks post-therapy without complication. In case treated with 6 mCi of `1`6`6Ho-SA, tissue destruction and widening of the esophageal lumen were observed and the inflammatory reaction propagated into the muscle layer. In case with 9 mCi of `1`6`6Ho-SA, severe esophagitis with cellular proliferation were seen, which resulted in further narrowing of the lumen. (author). 58 refs., 5 tabs., 14 figs

  11. Development of radioactive stent using HANARO research reactor

    International Nuclear Information System (INIS)

    Park, Kyung Bae; Kim, J. R.; Han, H. S.; Shin, B. C.; Kim, Y. M.; Cho, U. K.; Han, K. H.; Park, W. W.; Chung, Y. J.

    1997-10-01

    Radioactive cylindrical was prepared by neutron irradiation of pre-made non-radioactive '1'6'5 Ho-sleeve, which was made by casting polyurethane solution containing '1'6'5'Ho(NO 3 ) 3 in THF+DMF (10:1) solvent in cylindrical glass tube. Its length and diameter could be easily controlled by glass tube used as a mold. The radioactive stent assembly ('1'6'5Ho-SA) was prepared by covering the metallic stent with radioactive sleeve and then treated both ends with epoxy glue for prevention of peeling off the radioactive sleeve from stent (post-irradiation method). Other preparation method of radioactive stent is similar to that of the first one except using radioactive '1'6'6Ho(NO 3 ) 3 and glass tube fitted with metallic stent before casting (pre-irradiation method). Scanning electron microscopy and autoradiography exhibited that the distribution of '1'6'5Ho and '1'6'6Ho(NO 3 ) compounds in polyurethane matrix was nearly homogeneous. The present preparation methods of radioactive sleeve and stent are quite different from conventional method which metallic stent is coated or implanted with radionuclide. The ease with which the radioactive stent can be prepared and its homogeneous radiation emission make it an attractive radiation applicator for the treatment of esophagus cancer. As an animal studies, 6 pathologic specimens were obtained. An animal with 4 mCi of '1'6'6Ho-SA showed loss of epithelial tissue and inflammation at the submucosal layer 4 weeks after the procedure. Considerable improvement of the inflammatory reaction was observed 7 weeks post-therapy without complication. In case treated with 6 mCi of '1'6'6Ho-SA, tissue destruction and widening of the esophageal lumen were observed and the inflammatory reaction propagated into the muscle layer. In case with 9 mCi of '1'6'6Ho-SA, severe esophagitis with cellular proliferation were seen, which resulted in further narrowing of the lumen. (author). 58 refs., 5 tabs., 14 figs

  12. Update in urethral stents.

    Science.gov (United States)

    Bahouth, Z; Meyer, G; Yildiz, G; Nativ, O; Moskovitz, B

    2016-10-01

    Urethral stents were first introduced in 1988, and since then, they have undergone significant improvements. However, they did not gain a wide popularity and their use is limited to a small number of centers around the world. Urethral stents can be used in the entire urethra and for various and diverse indications. In the anterior urethra, it can be used to treat urethral strictures. In the prostatic urethra, they can be used for the treatment of prostatic obstruction, including benign, malignant and iatrogenic prostatic obstruction. Moreover, although not widely used, it can be also applied for the treatment of posterior urethral stricture and bladder neck contracture, usually resulting in urinary incontinence and the need for subsequent procedures. Our main experience are with Allium urethral stents, and as such, we provide the latest updates in urethral stents with special emphasis on the various types of Allium urethral stents: bulbar, prostatic and bladder neck stents.

  13. High prevalence of amblyopia risk factors in preverbal children with nasolacrimal duct obstruction.

    Science.gov (United States)

    Matta, Noelle S; Silbert, David I

    2011-08-01

    To report the percentage of children under the age of 3 with nasolacrimal duct obstruction (NLDO) and amblyopia risk factors who develop clinical evidence of amblyopia over time. Records of children under 3 years of age presenting to a pediatric oculoplastic specialist with NLDO between January 1, 2001, and August 8, 2009, were retrospectively reviewed to identify those who also had amblyopia risk factors. Amblyopia was diagnosed based on visual acuity and treatment history. A total of 375 children under the age of 3 had NLDO. Of these, 82 (22%) had amblyopia risk factors, and 70 received a follow-up examination. Average age at first visit was 12 months (1-27 months). In all patients with anisometropia and unilateral NLDO, the side with the NLDO had higher hyperopia. Of the 70 with risk factors, 44 (63%) were later treated for amblyopia: 29 with spectacles alone, 2 with occlusion therapy, 13 with spectacles and occlusion therapy. Six patients required strabismus surgery. In all patients with anisometropia and unilateral NLDO, the side with the NLDO had higher hyperopia. The percentage of children identified with amblyopia risk factors who later develop clinical amblyopia was much higher than the 1.6% to 3.6% expected in a cohort of normal children. Copyright © 2011 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  14. Nanoreinforced shape memory polyurethane

    Science.gov (United States)

    Richardson, Tara Beth

    Shape memory polymers (SMPs) are functional materials, which find applications in a broad range of temperature sensing elements and biological micro-electro-mechanical systems (MEMS). These polymers are capable of fixing a transient shape and recovering to their original shape after a series of thermo-mechanical treatments. Generally, these materials are thermoplastic segmented polyurethanes composed of soft segments, usually formed by a polyether macroglycol, and hard segments formed from the reaction of a diisocyanate with a low molecular mass diol. The hard segment content is a key parameter to control the final properties of the polymer, such as rubbery plateau modulus, melting point, hardness, and tensile strength. The long flexible soft segment largely controls the low temperature properties, solvent resistance, and weather resistance properties. The morphology and properties of polyurethanes (PU) are greatly influenced by the ratio of hard and soft block components and the average block lengths. However, in some applications, SMPs may not generate enough recovery force to be useful. The reinforcement of SMPs using nanofillers represents a novel approach of enhancing the performance of these materials. The incorporation of these fillers into SMPs can produce performance enhancements (particularly elastic modulus) at small nanoparticle loadings (˜1-2 wt %). An optimal performance of nanofiller-polymer nanocomposites requires uniform dispersion of filler in polymers and good interfacial adhesion. The addition of nanofillers like cellulose nanofibers (CNF), conductive cellulose nanofibers (C-CNF), and carbon nanotubes (CNTs) allows for the production of stiffer materials with deformation capacity comparable to that of the unfilled polymer. Additionally, the use of conductive nanoreinforcements such as C-CNF and CNTs leads to new pathways for actuation of the shape memory effect. During this work, thermoplastic shape memory polyurethanes were synthesized with

  15. Occupational urticaria from welding polyurethane

    Energy Technology Data Exchange (ETDEWEB)

    Kanerva, L.; Estlander, T.; Jolanki, R.; Laehteenmaeki, M.T.Ke.; Keskinen, H. (Institute of Occupational Health, Helsinki (Finland))

    1991-05-01

    An urticarial reaction associated with high fever developed in a welder on four occasions while he was welding steel profiles filled with polyurethane. The fumes emitted during pyrolysis of polyurethane and inhaled by the patient probably caused the urticarial reaction. Provocation tests with two pyrolysis products, 4,4-diphenylmethane diisocyanate and 4,4-diaminophenylmethane, were negative. This case demonstrates the difficulty in detecting the cause of urticaria induced by airborne chemicals.

  16. Lignin-based polyurethane materials

    OpenAIRE

    Cateto, C.A.; Barreiro, M.F.; Rodrigues, A.E.; Belgacem, M.N.

    2008-01-01

    Four technical lignins (Alcell, Indulin AT, Sarkanda and Curan 27-11P) were used as macromonomers in the synthesis of polyurethane materials following two global approaches. In the first one Alcell and Indulin AT lignins were used directly as co-monomers in combination with a linear polycaprolactone (PCL) in order to produce polyurethane elastomers where lignin content varied between 10 and 25% (w/w) with respect to polyol mixture (PCL+lignin). The thermomechanical properties o...

  17. Efficacy of a dexamethasone-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt: an experimental study in a swine model

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Oh, Joo Hyeogn; Park, Young Koo; Song, Ho Young; Park, Sang Joon; Yuk, Sun Hong

    2005-01-01

    We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM)-eluting nitinol stent to inhibit the pseudointimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic shunt tract (TIPS) of a swine. Fifteen stents were constructed using 0.15 mm-thick nitinol wire; they were 60 mm in length and 10 mm in diameter. The metallic stents were then classified into three types; type 1 and 2 was coated with the mixture of 12% and 20%, respectively, of DM solution and polyurethane (PU), while type 3 was a bare stent that was used for control study. In fifteen swine, each type of stent was implanted in the TIPS tract of 5 swine, and each animal was sacrificed 2 weeks after TIPS creation. The proliferation of the pseudointima was evaluated both on follow-up portogram and pathologic examination. One TIPS case, using the type 1 stent, and two TIPS cases, using the type 2 stent, maintained their luminal patency while the others were all occluded. On the histopathologic analysis, the mean of the maximum pseudointimal hyperplasia was expressed as the percentage of the stent radius that was patent, and these values were 51.2%, 50% and 76% for the type 1, 2, and 3 stents, respectively. The DM-eluting stent showed a tendency to reduce the development of pseudointimal hyperplasia in the TIPS tract of a swine model with induced-portal hypertension

  18. Selection and fabrication of a non-woven polycarbonate urethane cover for a tissue engineered airway stent.

    Science.gov (United States)

    Chen, Weiluan; Clauser, Johanna; Thiebes, Anja Lena; McGrath, Donnacha J; McHugh, Peter E; Steinseifer, Ulrich; Jockenhoevel, Stefan; Hennink, Wim E; Kok, Robbert Jan

    2016-11-30

    One of the major problems in end-stage bronchotracheal cancer is stenosis of the upper airways, either due to luminal ingrowth of the tumor or mucus plugging. Airway stents that suppress tumor ingrowth and sustain mucociliary transport can alleviate these problems in end-stage bronchial cancer. We evaluated different types of polymeric covers for a tissue engineered airway stent. The distinguishing feature of this stent concept is that respiratory epithelial cells can grow on the luminal surface of the stent which facilitates mucociliary clearance. To facilitate growth of epithelial cells at the air-liquid interface of the stent, we developed a polyurethane cover that allows transport of nutrients to the cells. Nonwoven polycarbonate urethane (PCU) covers were prepared by a spraying process and evaluated for their porosity and glucose permeability. Respiratory epithelial cells harvested from sheep trachea were cultured onto the selected PCU cover and remained viable at the air-liquid interface when cultured for 21days. Lastly, we evaluated the radial force of a PCU-covered nitinol stent, and showed the PCU covers did not adversely affect the mechanical properties of the stents for their intended application in the smaller bronchi. These in vitro data corroborate the design of a novel airway stent for palliative treatment of bronchotracheal stenosis by combination of stent-technology with tissue-engineered epithelial cells. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Hemodynamic comparison of stent configurations used for aortoiliac occlusive disease.

    Science.gov (United States)

    Groot Jebbink, Erik; Mathai, Varghese; Boersen, Johannes T; Sun, Chao; Slump, Cornelis H; Goverde, Peter C J M; Versluis, Michel; Reijnen, Michel M P J

    2017-07-01

    Endovascular treatment of aortoiliac occlusive disease entails the use of multiple stents to reconstruct the aortic bifurcation. Different configurations have been applied and geometric variations exist, as quantified in previous work. Other studies concluded that specific stent geometry seems to affect patency. These variations may affect local flow patterns, resulting in different wall shear stress (WSS) and oscillating shear index (OSI). The aim of this study was to compare the effect of different stent configurations on flow perturbations (recirculation and fluid stasis), WSS, and OSI in an in vitro setup. Three different stent configurations were deployed in transparent silicone models: bare-metal kissing (BMK) stents, covered kissing (CK) stents, and the covered endovascular reconstruction of the aortic bifurcation (CERAB) configuration. Transparent covered stents were created with polyurethane to enable visualization. Models were placed in a circulation setup under physiologic flow conditions. Time-resolved laser particle image velocimetry techniques were used to quantify the flow, and WSS and OSI were calculated. The BMK configuration did not show flow disturbances at the inflow section, and WSS values were similar to the control. An area of persistent low flow was observed throughout the cardiac cycle in the area between the anatomic bifurcation and neobifurcation. The CK model showed recirculation zones near the inflow area of the stents with a resulting low average WSS value and high OSI. The proximal inflow of the CERAB configuration did not show flow disturbances, and WSS values were comparable to control. Near the inflow of the limbs, a minor zone of recirculation was observed without changes in WSS values. Flow, WSS, and OSI on the lateral wall of the proximal iliac artery were undisturbed in all models. The studied aortoiliac stent configurations have distinct locations where flow disturbances occur, and these are related to the radial mismatch

  20. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon; Seo, Tae-Seok; Yuk, Soon Hong; Kim, Young-Hwa; Cho, Yong-Mee

    2005-01-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean±standard deviation, 46.88±23.75) than in the CS (73.75±14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63±2.05) than in CS (3.49±2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  1. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon [University of Ulsan College of Medicine, Department of Radiology, Asan Medical Center, Seoul (Korea); Seo, Tae-Seok [Gachon Medical School, Department of Radiology, Gil Medical Center, Inchon (Korea); Yuk, Soon Hong [Hannam University, Department of Polymer Science and Engineering, College of Engineering, Daejeon (Korea); Kim, Young-Hwa [Soonchunhyang University Chonan Hospital, Department of Radiology, Chonan (Korea); Cho, Yong-Mee [University of Ulsan College of Medicine, Department of Pathology, Asan Medical Center, Seoul (Korea)

    2005-06-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean{+-}standard deviation, 46.88{+-}23.75) than in the CS (73.75{+-}14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63{+-}2.05) than in CS (3.49{+-}2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  2. What Is a Stent?

    Science.gov (United States)

    ... clot at the stent site. Blood clots can cause a heart attack , stroke , or other serious problems. The risk of blood clots is greatest during the first few months after the stent is placed in the artery. Your doctor will likely recommend that you take aspirin and another anticlotting ...

  3. Characterization of nanostructured ureteral stent with gradient degradation in a porcine model

    Directory of Open Access Journals (Sweden)

    Wang XQ

    2015-04-01

    Full Text Available Xiaoqing Wang,1 Hongli Shan,2 Jixue Wang,1 Yuchuan Hou,1 Jianxun Ding,3 Qihui Chen,1 Jingjing Guan,1 Chunxi Wang,1 Xuesi Chen31Department of Urology, the First Hospital of Jilin University, 2Department of Clinical Laboratory, the First Hospital of Jilin University, 3Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, People’s Republic of ChinaAbstract: A tubular poly(ε-caprolactone (PCL/poly(lactide-co-glycolide (PLGA ureteral stent composed of nanofibers with micropores was fabricated by double-needle electrospinning. The stent was ureteroscopically inserted into six Changbai pigs, and the commercial polyurethane Shagong® stent was inserted into four pigs as control. Intravenous pyelography revealed that the PCL/PLGA stent gradually degraded from the distal end to proximal terminal, and all stents were completely degraded at 10 weeks post-insertion. No significant difference was observed in hydronephrosis severity between the two groups. The levels of serum creatinine and urine pH remained similar throughout the study in the two groups, but the number of white blood cells in the urine was significantly higher in the Shagong® stent group. On Day 70, histological evaluation indicated equivalent histological severity scores in the middle and distal ureter sections and bladder in the two groups. However, the PCL/PLGA stent-implanted pigs had significantly lower mean severity scores in the kidney and proximal ureter sites. These data revealed that the PCL/PLGA stent degraded in a controlled manner, did not induce obstruction, and had a lower urothelial impact in comparison to the Shagong® stent, indicating that the stent exhibited great potential for clinical application.Keywords: nanocomposites, polyesters, poly(ε-caprolactone, poly(lactide-co-glycolide, hydronephrosis severity

  4. Nasolacrimal duct obstruction as a complication of iodine-131 therapy in patients with thyroid cancer.

    Science.gov (United States)

    Fard-Esfahani, Armaghan; Farzanefar, Saeed; Fallahi, Babak; Beiki, Davood; Saghari, Mohsen; Emami-Ardekani, Alireza; Majdi, Mina; Eftekhari, Mohammad

    2012-10-01

    There are few studies evaluating the effect of radioioine therapy on the lacrimal drainage system. This study reports on symptomatic and asymptomatic nasolacrimal duct obstruction (NLDO) as complications of high-dose radioiodine therapy in these patients. Eighty-one cases were randomly selected from a population of radioiodine-treated differentiated thyroid carcinoma patients and were enrolled in a historical cohort study. The patients were categorized into four subgroups on the basis of the received cumulative dose of iodine-131 (I-131). In addition, 17 age-matched and sex-matched individuals were selected as the control group. Using dacryoscintigraphy and a clinical datasheet, the patients and controls were evaluated for partial or complete and symptomatic or asymptomatic NLDO. The data on different subgroups of patients were compared with the data of the control group. Twenty-nine out of 162 exposed eyes (18%) and three out of 34 control eyes (9%) had evidence of NLDO on scintigraphic images. Among patients treated with less than 11.1 GBq of I-131 (subgroup A), six out of 78 eyes (7.7%) had partial or complete NLDO. This was evident in 23 out of 84 eyes (27.4%) among patients treated with 11.1 GBq or more (subgroup B). The frequency of complete NLDO increases significantly when the cumulative dose of radioiodine exceeds 11.1 GBq (2.9% in the control group, 3.8% in subgroup A, and 23.8% in subgroup B; P=0.006). NLDO may be considered as a side effect of I-131 therapy, especially with a cumulative dose of 11.1 GBq or more.

  5. Three-Dimensional Reconstruction of the Bony Nasolacrimal Canal by Automated Segmentation of Computed Tomography Images.

    Directory of Open Access Journals (Sweden)

    Lucia Jañez-Garcia

    Full Text Available To apply a fully automated method to quantify the 3D structure of the bony nasolacrimal canal (NLC from CT scans whereby the size and main morphometric characteristics of the canal can be determined.Cross-sectional study.36 eyes of 18 healthy individuals.Using software designed to detect the boundaries of the NLC on CT images, 36 NLC reconstructions were prepared. These reconstructions were then used to calculate NLC volume. The NLC axis in each case was determined according to a polygonal model and to 2nd, 3rd and 4th degree polynomials. From these models, NLC sectional areas and length were determined. For each variable, descriptive statistics and normality tests (Kolmogorov-Smirnov and Shapiro-Wilk were established.Time for segmentation, NLC volume, axis, sectional areas and length.Mean processing time was around 30 seconds for segmenting each canal. All the variables generated were normally distributed. Measurements obtained using the four models polygonal, 2nd, 3rd and 4th degree polynomial, respectively, were: mean canal length 14.74, 14.3, 14.80, and 15.03 mm; mean sectional area 15.15, 11.77, 11.43, and 11.56 mm2; minimum sectional area 8.69, 7.62, 7.40, and 7.19 mm2; and mean depth of minimum sectional area (craniocaudal 7.85, 7.71, 8.19, and 8.08 mm.The method proposed automatically reconstructs the NLC on CT scans. Using these reconstructions, morphometric measurements can be calculated from NLC axis estimates based on polygonal and 2nd, 3rd and 4th polynomial models.

  6. Polyurethane adhesive ingestion.

    Science.gov (United States)

    Fitzgerald, Kevin T; Bronstein, Alvin C

    2013-02-01

    Polyurethane adhesives are found in a large number of household products in the United States and are used for a variety of purposes. Several brands of these expanding wood glues (those containing diphenylmethane diisocyanate [MDI]) have the potential to form gastrointestinal (GI) foreign bodies if ingested. The ingested adhesive forms an expanding ball of glue in the esophagus and gastric lumen. This expansion is caused by a polymerization reaction using the heat, water, and gastric acids of the stomach. A firm mass is created that can be 4-8 times its original volume. As little as 2 oz of glue have been reported to develop gastric foreign bodies. The obstructive mass is reported to form within minutes of ingestion of the adhesive. The foreign body can lead to esophageal impaction and obstruction, airway obstruction, gastric outflow obstruction, mucosal hemorrhage, ulceration, laceration, perforation of the esophageal and gastric linings, and death. Clinical signs following ingestion include anorexia, lethargy, vomiting, tachypnea, and abdominal distention and pain, and typically develop within 12 hours. Clinical signs may depend upon the size of the mass. If left untreated, perforation and rupture of the esophagus or stomach can occur. The glue mass does not stick to the GI mucosa and is not always detectable on abdominal palpation. Radiographs are recommended to confirm the presence of the "glue-ball" foreign body, and radiographic evidence of the obstruction may be seen as early as 4-6 hours following ingestion. Emesis is contraindicated owing to the risk of aspiration of the glue into the respiratory tree or the subsequent lodging of the expanding glue mass in the esophagus. Likewise, efforts to dilute the glue and prevent the formation of the foreign body through administration of liquids, activated charcoal, or bulk-forming products to push the foreign body through the GI tract have proven ineffective. Even endoscopy performed to remove the foreign body has

  7. 40 CFR 721.8090 - Polyurethane polymer.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Polyurethane polymer. 721.8090 Section... Substances § 721.8090 Polyurethane polymer. (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as a polyurethane polymer (P-94-47) is subject...

  8. Stent intussusception after thromboaspiration through a platinum chrome stent: a particular case of longitudinal stent deformation.

    Science.gov (United States)

    Mila, Rafael; Vignolo, Gustavo; Trujillo, Pedro

    2015-04-01

    The need to improve stent deliverability has led to the development of thinner and more flexible stents. However, there is concern about decreased longitudinal strength. The number of longitudinal stent deformation reports has dramatically increased. We report a case of stent longitudinal deformation after thromboaspiration through a new generation platinum chrome bare metal stent. Images show an "intussusception effect," an extreme form of the previously described "concertina deformation," as the mechanism of shortening. Since stent technology is constantly evolving, newer devices will probably be designed to have less susceptibility to longitudinal stent deformation.

  9. Benign and malignant tracheobronchial stritures:long term follow-up of treatment with polyurethance;covered retrievable expandable nitinol stents

    International Nuclear Information System (INIS)

    Kim, Ho Sung; Song, Ho Young; Kim, Tae Hyung; Kang, Sung Gwon; Yoon, Hyun Ki; Sung, Kyu Bo

    2001-01-01

    To assess the safety and long term effectiveness of polyurethane-covered retrievable expandable nitinol stents in the treatment of benign and malignant tracheobronchial strctures. Under fluoroscopic guidance, the stents were placed in 32 patients with dyspnea whose strictures were malignant in 15 cases and benign 17. A stent was removed when complications occurred, or -electively- 2-6 months after placement in patients with benign strictures. The range of follow- up period was 1-98 weeks (median, 47; range,50) weeks. Stent placement was well tolerated in 30 patients. After placement, all 32 showed immdiate symptom improvment and in none were complications such as ingrowth of a tumor or granulation tissue oaserved during the follow up period. Stent migration occurred in six patients. In one of six and four of five patients from whom, respectively, stents head been electively removed two and six months after placement, tracheobronchial rsetenosis did not occur during follow up. Second stents were placed in six patients in whom dyspnea recurred due to restenosis after elective stent removal. In two of these six, stents were removed six months after placement and dyspnea did not recur during follow up. The use of covered retrievable tracheobronchial stents is safe and feasible in the conservative treatment of patients with malignant tracheobronchial strictures as well as for selected patients with benign strictures

  10. A comparison between monocanalicular and pushed monocanalicular silicone intubation in the treatment of congenital nasolacrimal duct obstruction

    Directory of Open Access Journals (Sweden)

    Dima Andalib

    2014-12-01

    Full Text Available AIM: To compare the success rate of monocanalicular versus pushed monocanalicular silicone intubation (PMCI of the nasolacrimal duct for congenital nasolacrimal duct obstruction (CNLDO.METHODS: In a prospective randomized clinical trial 53 eyes of 49 patients with CNLDO underwent either monocanalicular silicone intubation (MCI (n=28 eyes or PMCI (n=25 eyes. All procedures were performed by 1 oculoplastic surgeon. Treatment success was defined as the complete resolution of epiphora at 3mo after tube removal.Results: The surgical outcome was assessed in 20 eyes with MCI and 20 eyes with PMCI. The mean age of treatment was 26.25±10.08mo (range, 13-49mo for MCI and 26.85±12.25mo (range, 16-68mo for PMCI. Treatment success was achieved in 18 of 20 eyes (90.0% in the MCI group compared with 10 of 20 eyes (50% in the PMCI group (P=0.01. In the PMCI group, the tube loss (30% was greater than the MCI group (5%, however the differences between the 2 groups proved to be not significant (P=0.91.CONCLUSION: Our results indicate that MCI has higher success rate in CNLDO treatment compared with PMCI in this small series of patients.

  11. Effectiveness of Synthetic Polyurethane Foam as a Nasal Packing Material in Endoscopic Endonasal Dacryocystorhinostomy.

    Science.gov (United States)

    Lee, Joonsik; Lee, Hwa; Lee, Hyun Kyu; Chang, Minwook; Park, Minsoo; Baek, Sehyun

    2015-10-01

    To compare the effects of 2 nasal packing materials, synthetic polyurethane foam (absorbable) and expandable polyvinyl acetate (nonabsorbable), on the surgical success rate and postoperative complications after endoscopic endonasal dacryocystorhinostomy (EDCR). A retrospective medical review of 459 patients (580 eyes) who underwent EDCR for primary acquired nasolacrimal duct obstruction at Korea University Guro Hospitals from January 2009 to February 2014. Surgical success rate (anatomical, functional), postoperative complications (granuloma, synechia, bleeding, and infection) were compared between the 2 groups, absorbable (318 eyes) and nonabsorbable (262 eyes). The absorbable group showed better results in surgical success rate regarding anatomical (90.5% versus 76.3%, P = 0.00) and functional (89.3% versus 75.9%, P = 0.00). Granulomas developed less frequently in the absorbable group (24.5% versus 38.9%, P = 0.00). Also, bleeding and crust were less frequent in the absorbable group (P = 0.00). Infections were less frequent in the nonabsorbable group (1.52%) compared with the absorbable group (7.86%, P = 0.00). The rate of revision surgery was lower in the absorbable group (7.86% versus 20.9%, P = 0.00). As for the influence of secondary outcomes to the surgical success by multiple logistic regression, granulomas had the largest effect on surgical success either anatomical or functional (odds ratio = 82.393 to anatomical and 44.058 to functional). Synechia had the second largest effect on surgical success (odds ratio = 11.897 to anatomical and 9.605 to functional). The authors suggest that using a synthetic polyurethane foam as a nasal packing material is not only a surgical option, but also a crucial and essential procedure in EDCR.

  12. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar

    2014-01-01

    to determine the effects of fabrication processes on the topography of the auxetic stent. RESULTS AND CONCLUSIONS: The elastic recoil (3.3%) of the in vitro mechanical analysis showed that the auxetic stent design effectively maintained the luminal patency of the coronary artery. Also, the auxetic coronary...... was obtained via laser cutting, and surface treatment was performed with acid pickling and electropolishing, followed by an annealing process. In vitro mechanical analysis was performed to analyze the mechanical performance of the auxetic coronary stent. Scanning electronic microscopy (SEM) was used...

  13. Tracheomalatia, to stent or not to stent

    Directory of Open Access Journals (Sweden)

    Irena Perić

    2015-01-01

    Full Text Available Benign thyroid disorders such as goiter, especially retrosternal, can cause tracheostenosis by extrinsic tracheal compression, which is due to the lack of specific symptoms often misdiagnosed. Tracheomalatia develops as a result to long term tracheal compression and refers to weakness of the trachea characterized by softness of the tracheal cartilage arches and by loss of regular tracheal structure. Tracheomalatia is characterized by reduction of the endotracheal lumen and may affect the entire trachea or may be localized to one portion of it. We present the case of a 72-year old patient with distinct tracheostenosis and tracheomalatia, caused by long term pressure by the retrosternal goiter. We have been monitoring the patient for last 20 years after the second endotracheal stent had been placed. The first one was placed 34 years ago, in 1981. On both occasions granulation tissue and colonization of bacteria occurred. In the end the placed stents were rejected and migrated to the main carina. Despite the tracheal diameter narrower than 5 mm the patient has been living normally without the stent for 17 years, with the exception of no hard physical labor. He had a few short term antibiotic therapies and bronchial toilets during symptomatic deteriorations. Diagnosing retrosternal goiter and surgical treatment on time is of crucial importance in cases such as this one. Considering the complications caused by the stent, our opinion is that the majority of patients may require conservative treatment with closely monitoring during respiratory infections.

  14. Polyurethane Foams with Pyrimidine Rings

    Directory of Open Access Journals (Sweden)

    Kania Ewelina

    2014-09-01

    Full Text Available Oligoetherols based on pyrimidine ring were obtained upon reaction of barbituric acid with glycidol and alkylene carbonates. These oligoetherols were then used to obtain polyurethane foams in the reaction of oligoetherols with isocyanates and water. The protocol of foam synthesis was optimized by the choice of proper kind of oligoetherol and synthetic composition. The thermal resistance was studied by dynamic and static methods with concomitant monitoring of compressive strength. The polyurethane foams have similar physical properties as the classic ones except their enhanced thermal resistance. They stand long-time heating even at 200°C. Moreover thermal exposition of foams results generally in increase of their compressive strength.

  15. Bioactive polyurethane implants with hydroxyapatite

    Energy Technology Data Exchange (ETDEWEB)

    Rozhnova, R.; Kebuladze, I.; Galatenko, N. [NAS Ukraine, Kiev (Ukraine). Dept. of Polymers of Medical Appointment

    2001-07-01

    Biologically active polyurethane compositions for plastic of bone defects that contain bioceramic - hydroxyapatite (HAP) and immunomodulator - levamisole (LEV) were designed. The influence of the biologically active fillers in structure polyurethane compositions on their physical and chemical properties in condition in vivo by method of Equilibrium Swelling, method of IR-spectroscopy, roentgen-structural analysis was studied. The introduce in structure of the biodegraded polymeric matrix of HAP is established to promote accumulation of the inorganic component of bone tissue in vivo which is being by basis of the bone formation in regenerating tissue. (orig.)

  16. Polyurethane - positioning aids in radiotherapy

    International Nuclear Information System (INIS)

    Alzen, G.; Boeck, E.G.; Thelen, M.; Kutzner, J.

    1985-01-01

    A simple and cheap method is described for the manufacturing of individual positioning aids made of foamed polyurethane. Some examples are given to demonstrate the applicability of these positioning aids for the irradiation of different body regions. The reproducibility of the radiation field in the head and neck area was investigated with and without positioning aid. It was proved that the field is adjusted more exactly when positioning aids are applied. The dosimetric investigations performed showed a negligible influence of foamed polyurethane on the radiation quality. So the positioning aids could be left within the radiation field when drawing the field borders. (orig.) [de

  17. Stent Fracture after Everolimus-Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Ali S. Almasood

    2011-01-01

    Full Text Available Compared with bare-metal stents, drug-eluting stents (DES have greatly reduced the risk of in-stent restenosis (ISR by inhibiting neointimal growth. Nevertheless, DES are still prone to device failure, which may lead to cardiac events. Recently, stent fracture (SF has emerged as a potential mechanism of DES failure that is associated with ISR. Stent fracture is strongly related to stent type, and prior reports suggest that deployment of sirolimus eluting stents (SES may be associated with a higher risk of SF compared to other DES. Everolimus eluting stents (EESs represent a new generation of DES with promising results. The occurrence of SF with EES has not been well established. The present paper describes two cases of EES fracture associated with ISR.

  18. Indwelling Stent Embedded with Light-Emitting Diodes for Photodynamic Therapy of Malignant Biliary Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Baran, Timothy M., E-mail: timothy.baran@rochester.edu [University of Rochester Medical Center, Department of Imaging Sciences (United States); Mironov, Oleg, E-mail: oleg.mironov@uhn.ca [University Health Network, The Joint Department of Medical Imaging (Canada); Sharma, Ashwani K., E-mail: Ashwani-Sharma@URMC.Rochester.edu; Foster, Thomas H., E-mail: thomas.foster@rochester.edu [University of Rochester Medical Center, Department of Imaging Sciences (United States)

    2016-06-15

    PurposeWe describe the design and preliminary characterization of a stent incorporating light-emitting diodes (LEDs) for photodynamic therapy (PDT) of malignant biliary obstruction.MethodsA prototype was constructed with red (640 nm) LEDs embedded in a 14.5 French polyurethane tube. The device was evaluated for optical power and subjected to physical and electrical tests. PDT-induced reactive oxygen species were imaged in a gel phantom.ResultsThe stent functioned at a 2.5-cm bend radius and illuminated for 6 months in saline. No stray currents were detected, and it was cool after 30 minutes of operation. Optical power of 5–15 mW is applicable to PDT. Imaging of a reactive oxygen indicator showed LED-stent activation of photosensitizer.ConclusionsThe results motivate biological testing and design optimization.

  19. Degradation and antibacterial properties of magnesium alloys in artificial urine for potential resorbable ureteral stent applications.

    Science.gov (United States)

    Lock, Jaclyn Y; Wyatt, Eric; Upadhyayula, Srigokul; Whall, Andrew; Nuñez, Vicente; Vullev, Valentine I; Liu, Huinan

    2014-03-01

    This article presents an investigation on the effectiveness of magnesium and its alloys as a novel class of antibacterial and biodegradable materials for ureteral stent applications. Magnesium is a lightweight and biodegradable metallic material with beneficial properties for use in medical devices. Ureteral stent is one such example of a medical device that is widely used to treat ureteral canal blockages clinically. The bacterial colony formation coupled with the encrustation on the stent surface from extended use often leads to clinical complications and contributes to the failure of indwelling medical devices. We demonstrated that magnesium alloys decreased Escherichia coli viability and reduced the colony forming units over a 3-day incubation period in an artificial urine (AU) solution when compared with currently used commercial polyurethane stent. Moreover, the magnesium degradation resulted in alkaline pH and increased magnesium ion concentration in the AU solution. The antibacterial and degradation properties support the potential use of magnesium-based materials for next-generation ureteral stents. Further studies are needed for clinical translation of biodegradable metallic ureteral stents. Copyright © 2013 Society of Plastics Engineers.

  20. Additive Manufacturing of Polyurethane Materials

    Energy Technology Data Exchange (ETDEWEB)

    Kunc, Vlastimil [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lindahl, John M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Minneci, Robert P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pyzik, Alek [Dow Chemical Company, Saginaw, MI (United States); Gorin, Craig [Dow Chemical Company, Midland, MI (United States); Allen, Sharon [Dow Chemical Company, Midland, MI (United States); Wilson, Keith [Dow Chemical Company, Midland, MI (United States); Howard, Kevin [Dow Chemical Company, Midland, MI (United States)

    2017-08-10

    ORNL worked with The DOW Chemical Company to validate the feasibility of 3D printing DOW’s polyurethane (PU) materials using ORNL’s equipment and know-how. This led to the development of the first directly-3D-printable PU material.

  1. Open-celled polyurethane foam

    Science.gov (United States)

    Russell, L. W.

    1970-01-01

    Open-celled polyurethane foam has a density of 8.3 pounds per cubic foot and a compressive strength of 295 to 325 psi. It is useful as a porous spacer in layered insulation and as an insulation material in vacuum tight systems.

  2. Washing Off Polyurethane Foam Insulation

    Science.gov (United States)

    Burley, Richard K.; Fogel, Irving

    1990-01-01

    Jet of hot water removes material quickly and safely. Simple, environmentally sound technique found to remove polyurethane foam insulation from metal parts. Developed for (but not limited to) use during rebuilding of fuel system of Space Shuttle main engine, during which insulation must be removed for penetrant inspection of metal parts.

  3. Clinical outcomes of secondary stent-in-stent self-expanding metal stent placement for primary stent malfunction in malignant gastric outlet obstruction.

    Science.gov (United States)

    Park, Jun Chul; Park, Jae Jun; Cheoi, Kungseok; Chung, Hyunsoo; Lee, Hyuk; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan

    2012-12-01

    Although a substantial number of patients require secondary stents insertion due to primary stent malfunction in malignant gastric outlet obstruction, data on the outcomes of secondary self-expanding metal stents are sparse. To investigate clinical outcomes and factors related with secondary stent malfunction in patients with malignant gastric outlet obstruction given secondary stent-in-stent self-expanding metal stent insertion. For this retrospective study, a total 77 patients who underwent secondary stent-in-stent self-expanding metal stent placement for primary stent malfunction in malignant gastric outlet obstruction were enrolled. We compared the effectiveness and complications of secondary covered and uncovered stents and explored the predictive factors for stent malfunction. Stent-in-stent self-expanding metal stent placements were technically successful in all patients. Both groups also had comparable clinical success rates (covered stent, 87.2% and uncovered stent, 90.0%, P = 1.000). Stent malfunction rates (31.9% and 36.7% respectively, P = 0.805) and median patency time of stent (165 [95% confidence interval: 112-218] and 165 [95% confidence interval: 126-204] days, respectively, P = 0.358) were similar between secondary covered and uncovered stents. Longer patients' survival time (≥ 100 days) was associated with increased risk of stent malfunction (odds ratio: 4.598; 95% confidence interval: 1.473-14.355; P = 0.009). Secondary stent-in-stent self-expanding metal stent placement is feasible and effective treatment for primary stent malfunctions in malignant gastric outlet obstruction. Covered and uncovered stent are equally acceptable in terms of stent-related complications and stent patency, regardless of primary stent type. Copyright © 2012 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  4. Clinical and histological effects of the temporary occlusion of the rabbit nasolacrimal duct and point using cyanoacrylate adhesives

    Directory of Open Access Journals (Sweden)

    K.C.F. Cardoso

    2013-12-01

    Full Text Available The objective of this study was to evaluate the clinical and histological effects of occluding the nasolacrimal ducts and points of rabbits. For this study, 20 adult New Zealand rabbits, both males and females, weighing 3.2±0.4kg were allocated into two groups for n-butyl-cyanoacrylate occlusion (GB, n=10 or 2-octyl-cyanoacrylate occlusion (GO, n=10. The contralateral eyes served as the controls. The persistence of tears was evaluated daily using the Schirmer I test. Discomfort, eye discharge, epiphora, and conjunctival hyperemia were assessed prior to the procedure (T0 and during the 14 subsequent days (T1-T14. On days seven and 14, five animals from each group were euthanized, and their nasolacrimal ducts were collected, processed and analyzed by histology. In the GB group, the Schirmer test values differed from that at T0 at all of the subsequent time points, whereas there was no difference in the values observed from the GO group. Compared with the corresponding controls, the GO and GB groups differed significantly at almost all of the time points. When comparing the treatment groups, differences were found at T6, T7, T9, T10, T11, T12 and T14, with higher Schirmer values in the GB group. Epiphora was observed in the GB group from T1 to T8 and in the GO group from T1 to T6. Within seven days post-occlusion, histology revealed a moderate foreign body reaction, with marked necrosis and sloughing of the canalicular epithelium, in the GO group, which was absent at day 14. In the GB group, a marked inflammatory reaction and a mild foreign body reaction were found at day seven, and the foreign body reaction was prevalent at day 14. This study demonstrated that both adhesives were effective in obstructing the nasolacrimal ducts and points of rabbits and that their application and handling are easy and free of complications. However, both adhesives promoted inflammatory and foreign body reactions that evolved to repair and regeneration at day 14 of

  5. Renal PTA stenting

    International Nuclear Information System (INIS)

    Tsetis, D.

    2012-01-01

    Full text: Renal artery stenosis (RAS) is a common condition that may lead to hypertension, progressive renal dysfunction and cardiovascular morbidity. Catheter-based therapy for symptomatic, haemodynamically significant, RAS has become the preferred method of revascularization. Balloon angioplasty has been the traditional treatment of choice for fibromuscular dysplasia, however stents are increasingly used for the treatment of atheromatous lesions; in many cases-such as in ostial lesions-, direct stenting is strongly indicated. Despite the increased use of endovascular therapy for renal artery stenosis, there is still controversy regarding the optimal management and the net benefit of this treatment. Several randomized trials of balloon angioplasty or stenting for renal artery stenosis compared with medical therapy alone have been conducted, however these could not show definite advantage of endovascular therapy. Problems encountered with those trials include enrollment of small number of patients, frequent crossover from medical to interventional therapy compromising the intention-to-treat results, or selection of patients that are not expected to show clear benefit. The Angioplasty and Stenting for Renal Artery Lesions (ASTRAL) is the most important of these trials; however, it,s study design was faulty and therefore did not provide conclusive evidence to answer the question of whether angioplasty and stenting or medical therapy is the best treatment for haemodynamically significant RAS. All expectations are now focused on the Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial which was designed to answer the same question, and its methodologies took into consideration the weaknesses of the ASTRAL trial. Regarding stent device itself, it seems that the optimal design is probably a stainless steel, laser cut, open-cells stent mounted on a rapid exchange delivery balloon catheter compatible with 0.014-in and 0.018-in guidewire. As a future

  6. Ultrasound thrombolysis in stent thrombosis.

    Science.gov (United States)

    Rassin, T; Desmet, W; Piessens, J; Rosenschein, U

    2000-11-01

    Recent refinement in stent implantation technique and peri-procedural pharmacological treatment has lowered the incidence of stent thrombosis significantly. Still, all stent thromboses are associated with major adverse events. In previous studies it has been suggested that intravascular ultrasound fibrinolysis is safe and effective. In this report, ultrasound successfully reperfused thrombotically occluded stents. These observations suggest that ultrasound may dissolve occlusive platelet-rich thrombus effectively and safely. Cathet. Cardiovasc. Intervent. 51:332-334, 2000. Copyright 2000 Wiley-Liss, Inc.

  7. Future developments in biliary stenting

    Directory of Open Access Journals (Sweden)

    Hair CD

    2013-06-01

    Full Text Available Clark D Hair,1 Divyesh V Sejpal21Department of Medicine, Section of Gastroenterology and Hepatology, Baylor College of Medicine, Houston, TX, USA; 2Department of Medicine, Section of Gastroenterology, Hofstra North Shore-LIJ School of Medicine, North Shore University Hospital, Manhasset, NY, USAAbstract: Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting.Keywords: plastic stents, self-expandable metal stents, drug eluting stents, bioabsorbable stents, malignant biliary strictures, benign biliary strictures

  8. Management Of Encrusted Ureteral stents

    African Journals Online (AJOL)

    imac-3

    Mohammed V Military Hospital of Rabat, Morocco. Received 1November 2011; received in revised form 18 May 2012; accepted 14 July 2012. KEYWORDS. Ureteral stent;. JJ stent;. Encrustation. Abstract. Objectives: To present our experience in managing encrusted ureteral stents and to review the literature on the subject.

  9. High molecular weight polyurethanes and a polyurethane urea based on 1,4-butanediisocyanate

    NARCIS (Netherlands)

    Spaans, CJ; de Groot, JH; Dekens, FG; Pennings, AJ

    New biomedical polyurethanes and a polyurethane urea based on epsilon-caprolactone and 1,4-butanediisocyanate have been developed. On degradation, only non-toxic products are produced. The polyurethane urea with poly(epsilon-caprolactone) soft segments and butanediisocyanate/butanediamine hard

  10. Polyurethane adhesives in flat roofs

    OpenAIRE

    Bogárová Markéta; Stodůlka Jindřich; Šuhajda Karel

    2017-01-01

    It is necessary to stabilize individual layers of flat roofs, mainly because of wind suction. Apart from anchoring and surcharge, these layers can be secured by bonding. At present gluing is an indispensable and widely used stabilization method. On our market we can found many types of adhesives, most widely used are based on polyurethane. This paper focuses on problematic about stabilization thermal insulation from expanded polystyrene to vapor barrier from bitumen. One of the main issues is...

  11. Polyurethane adhesives in flat roofs

    Directory of Open Access Journals (Sweden)

    Bogárová Markéta

    2017-01-01

    Full Text Available It is necessary to stabilize individual layers of flat roofs, mainly because of wind suction. Apart from anchoring and surcharge, these layers can be secured by bonding. At present gluing is an indispensable and widely used stabilization method. On our market we can found many types of adhesives, most widely used are based on polyurethane. This paper focuses on problematic about stabilization thermal insulation from expanded polystyrene to vapor barrier from bitumen. One of the main issues is to calculate the exact amount of adhesive, which is required to guarantee the resistance against wind suction. In this problematic we can not find help neither in technical data sheets provided by the manufactures. Some of these data sheets contain at least information about amount of adhesive depending on location in roof plane and building height, but they do not specify the strength of such connection. It was therefore resorted to select several representatives polyurethane adhesives and their subsequent testing on specimens simulating the flat roof segment. The paper described the test methodology and results for two types of polyurethane adhesives.

  12. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels

    2013-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...

  13. Optimal training strategies for carotid stenting.

    Science.gov (United States)

    Schneider, Peter A

    2005-06-01

    Future participation in the treatment of carotid occlusive disease is dependent on training to perform carotid stent placement. Reviewed herein are strategies for training in carotid stenting. Included in this discussion are; the skills required for carotid stenting, the carotid stent learning curve, a comparison of training and credentialing, and the roles of simulators, courses, and hands-on experience in carotid stent training.

  14. Formulation, Preparation, and Characterization of Polyurethane Foams

    Science.gov (United States)

    Pinto, Moises L.

    2010-01-01

    Preparation of laboratory-scale polyurethane foams is described with formulations that are easy to implement in experiments for undergraduate students. Particular attention is given to formulation aspects that are based on the main chemical reactions occurring in polyurethane production. This allows students to develop alternative formulations to…

  15. Late in-stent thrombosis following carotid angioplasty and stenting.

    Science.gov (United States)

    Buhk, Jan-Hendrik; Wellmer, Andreas; Knauth, Michael

    2006-05-23

    Acute in-stent thrombosis is a well-known complication of carotid angioplasty and stenting (CAS) and often due to resistance to or inadequate treatment with platelet-inhibiting agents. The authors report three cases of a delayed in-stent thrombosis after more than a week but less than 3 months after CAS. In all cases, the postprocedural antiplatelet regimen was discontinued to enable the treatment of a relevant comorbidity.

  16. Self-expandable metalic endotracheal stent

    International Nuclear Information System (INIS)

    Do, Young Soo; Cho, Dae Soon; Cho, Kyung Ja; Lee, Young Soo; Lee, Mi Jae

    1993-01-01

    Six bare stents and six covered stents were inserted in the trachea of 12 dogs under general anesthesia. After 1-10 weeks of observation, the dogs were killed, and the trachea and lung were examined grossly and histologically. Pneumonia and stent migration were observed more frequently at covered stent group. Inflammatory change of the trachea was more severe at covered stent group. In conclusion, we believe that it is inadequate to insert silicone covered stent in the tracheobronchial tree. (Author)

  17. Polyurethane membranes for surgical gown applications

    Science.gov (United States)

    Ukpabi, Pauline Ozoemena

    The Occupational Safety and Health Administration (OSHA) recently issued a directive requiring all employers to supply personnel protective equipment to employees who are at risk of exposure to blood or other potentially infectious body fluids. For the healthcare worker, a wide variety of surgical gowns is available commercially but there are concerns over their barrier effectiveness and/or wearer comfort. To successfully create a barrier fabric which combines resistance to fluid penetration with comfort, a complete understanding of the relationship between membrane structure and functional properties is required. In this study, we investigated the surface properties of hydrophilicity and hydrophobicity in polyurethane membranes intended for use in surgical gowns. The polyurethane membranes were grafted with side chains of varying lengths, polyethylene glycol (PEG) being used for the hydrophilic modifications and perfluoroalkyl compounds (a monofunctional acid and a difunctional amino alcohol) for the hydrophobic modifications. The hydrophilic treatment was intended to improve the comfort properties of monolithic membranes without adversely affecting their barrier properties. The hydrophobic treatment, on the other hand, was intended to improve the fluid repellency and hence barrier properties of microporous membranes without adversely affecting their comfort properties. Reflection infrared spectroscopy showed that fluorine was successfully grafted onto the polyurethane backbone during the hydrophobic modification, but was not sensitive enough to detect PEG grafting in leached polyethylene glycol-treated polyurethanes. X-ray photoelectron spectroscopy showed that the perfluoroalkylated polyurethanes contained up to 40% fluorine on their surfaces and the PEG-treated polyurethanes showed an increase in their C-O content over the unmodified polyurethane. Scanning electron microscopy not only showed that perfluoroalkylation yielded polyurethane membranes with very

  18. Bacterial adherence to self-reinforced polyglycolic acid and self-reinforced polylactic acid 96 urological spiral stents in vitro.

    Science.gov (United States)

    Pétas, A; Vuopio-Varkila, J; Siitonen, A; Välimaa, T; Talja, M; Taari, K

    1998-01-01

    The aim of this study was to evaluate the bacterial adherence to biodegradable self-reinforced polyglycolic acid (SR-PGA) and self-reinforced poly-DL-lactic acid (SR-PLA 96) spiral stents in vitro. They are used as temporary urethral stents in urology. Gold-plated metal wire, polyurethane and latex were used as controls. Materials were incubated up to 28 days in artificial urine, after which a bacterial suspension was added. After detaching by sonication the adhesive bacteria were analysed as colony forming units (CFUs) and by scanning electron microscopy (SEM) analysis. Adhesion was more significantly correlated to stent bacterial type than to the tested material in both assays. No encrustation was seen on SR-PGA or SR-PLA 96. SR-PGA and SR-PLA 96 had no effect on the bacterial growth. In conclusion, the bacterial properties are equally or more important than the material properties in the adhesion process.

  19. Clinical results of carotid artery stenting with a nitinol self-expanding stent (SMART stent)

    Energy Technology Data Exchange (ETDEWEB)

    Drescher, Robert; Mathias, Klaus D.; Jaeger, Horst J.; Bockisch, Georg; Demirel, Eren; Gissler, Martin H.; Hauth, Elke [Department of Radiology, Staedtische Kliniken Dortmund, Beurhausstrasse 40, 44139 Dortmund (Germany); Department of Radiology and Microtherapy, University Witten/Herdecke (Germany)

    2002-10-01

    Our objective was to assess the technical feasibility and the clinical results of internal carotid artery (ICA) stenting using a nitinol self-expanding stent (SMART stent). In 13 patients 13 high-grade stenoses of the internal carotid artery were treated via an implantation of a SMART stent. In all cases a predilation of the stenosis and a postdilation within the stent were performed. Follow-up examinations were carried out in all patients after a period of 6 months. In each case the implantation of the stent was performed without technical complications. In 12 of 13 cases the stent was placed in the patients' internal carotid artery, in 1 case from the internal to the common carotid artery (CCA). The average degree of stenosis of 78% (70-95%) was reduced to an average of 2.8% (0-21%). The 6-month follow-up angiography showed an average degree of restenosis of 11.8% (0-29%) in 8 of 13 patients. Duplex sonography in the remaining 5 patients demonstrated patent stents. One patient showed brief neurological symptoms during the intervention. No further complications occurred during follow-up time. Treatment of internal carotid artery stenosis with the SMART stent seems technically feasible, safe, and promises long-term patency. (orig.)

  20. Synthesis of Polyurethane Modified Epoxy From Acrylic Polyol with Temperature Variation and Polyurethane Composition

    OpenAIRE

    Triwulandari, Evi; Ghozali, Muhammad

    2013-01-01

    Polyurethane-modified epoxy has been synthesized using acrylic polyol and tolonate as polyurethane component. Epoxy modification process was conducted at 50o, 70o and 90 oC; 10 %, 20 %, 30 %, 40 % (%w/w) polyurethane to epoxy; with solvent and without solvent as well. Characterization of polyurethane-modified epoxy has been done by determining rest of isocyanate to calculate isocyanate conversion level, Fourier Transform- Infra Red (FT-IR) analysis and 1H-Nuclear Magnetic Resonance (1H-NMR). ...

  1. The risk and prognostic impact of definite stent thrombosis or in-stent restenosis after coronary stent implantation

    DEFF Research Database (Denmark)

    Thayssen, Per; Jensen, Lisette Okkels; Lassen, Jens Flensted

    2012-01-01

    as time-dependent variables. A total of 12,277 patients were treated with stent implantation. Stent thrombosis was observed in 111 (0.9%) patients and in-stent restenosis in 503 (4.1%) patients within 12 months after the index PCI. Occurrence of stent thrombosis was associated with an increased risk...

  2. Thrombocytopenia associated with environmental exposure to polyurethane

    Energy Technology Data Exchange (ETDEWEB)

    Michelson, A.D. (Department of Pediatrics, University of Massachusetts Medical School, Worcester (United States))

    1991-10-01

    Few chemicals in the environment have been implicated as causes of isolated thrombocytopenia, and the evidence is usually less than convincing because the patients were not rechallenged with the chemical in vivo. In the present paper, a child is reported with the onset of thrombocytopenia in temporal association with environmental exposure to polyurethane. Five years after the initial thrombocytopenia had resolved, an inadvertent in vivo rechallenge with environmental polyurethane resulted in recurrence of the thrombocytopenia. This recurrence, together with the fact that only 1-4% of cases of idiopathic thrombocytopenic purpura in children recur, provided strong evidence for a causal role for the polyurethane exposure in this patient's thrombocytopenia. In summary, environmental exposure to polyurethane should be considered in the differential diagnosis of acquired thrombocytopenia in childhood.

  3. Polyurethane Binder Systems for Polymer Bonded Explosives

    National Research Council Canada - National Science Library

    Daniel, Merran A

    2006-01-01

    .... This report details the history of PBX binders, components of polyurethane binder systems, their properties and the procedures for obtaining the ingredients, as well as the basics of formulation...

  4. Modeling Decomposition of Unconfined Rigid Polyurethane Foam

    National Research Council Canada - National Science Library

    Hobbs, Michael

    1999-01-01

    The decomposition of unconfined rigid polyurethane foam has been modeled by a kinetic bond-breaking scheme describing degradation of a primary polymer and formation of a thermally stable secondary polymer...

  5. Flame Retardants Used in Flexible Polyurethane Foam

    Science.gov (United States)

    The partnership project on flame retardants in furniture seeks to update the health and environmental profiles of flame-retardant chemicals that meet fire safety standards for upholstered consumer products with polyurethane foam

  6. Silicone on Blending Vegetal Petrochemical Based Polyurethane

    OpenAIRE

    Flora E. Firdaus

    2010-01-01

    Polyurethane foam (PUF) is formed by a chemical reaction of polyol and isocyanate. The aim is to understand the impact of Silicone on synthesizing polyurethane in differentiate volume of molding. The method used was one step process, which is simultaneously caried out a blending polyol (petroleum polyol and soybean polyol), a TDI (2,4):MDI (4,4-) (80:20), a distilled water, and a silicone. The properties of the material were measured via a number of parameters, which are ...

  7. POLYURETHANE COMPOSITES AS DRUG CARRIERS:: RELEASE PATTERNS

    Directory of Open Access Journals (Sweden)

    M. V. Grigoreva

    2013-10-01

    Full Text Available Biodegradable polyurethanes attract interest of those developing composite materials for biomedical applications. One of their features is their ability to serve as carriers, or matrixes, for medicines and other bioactive compounds to produce a therapeutic effect in body through targeted and/or prolonged delivery of these compounds in the process of their controlled release from matrix. The review presents polyurethane composites as matrices for a number of drugs. The relation between structure of the composites and their degradability both in vitro and in vivo and the dependence of drug release kinetics on physicochemical properties of polyurethane matrix are highlighted. The release of drugs (cefazolin, naltrexone and piroxicam from the composites based on cross-linked polyurethanes (synthesized from laprols, Mw between 1,500 and 2,000 Da and toluylene diisocyanate demonstrated more or less the same pattern (about 10 days in vitro and three to five days in vivo. In contrast, the composites with dioxydine based on a linear polyurethanes (synthesized from oligotetramethilene glycol, Mw 1,000 Da, diphenylmethane-4,4’-diisocyanate and 1,4-butanediol retained their antimicrobial activity at least 30 days. They also showed a significantly higher breaking strength as compared to that of the composites based on cross-linked polyurethanes.

  8. Comparison of the occlusion of experiemntal craniojugular saccular aneurysms with covered stents

    International Nuclear Information System (INIS)

    Zhang Haixia; Li Minghua; Cheng Yingsheng; Fang Chun; Li Min

    2006-01-01

    Objective: To assess the effectiveness and biocompatibility of balloon-expanding, stainless steel stents covered with biomembrane (BM-SSS) and polyurethane membrane (PUM-SSS) in the treatment of experimental saccular aneurysms in a canine model and to observe the ablation of aneurysm with preservation of the parent vessel. Methods: Sixteen healthy mongrel canines were included in our study. 26 of 29 successful experimental aneurysms were treated with covered stents, another 3 were untreated to serve as controls. Altogether there were fourteen BM-SSS and twelve PUM-SSS were placed endovascularly in the common carotid arteries covering the orifice of the aneurysms. Control angiography was performed immediately after the procedure and after 2 weeks, 4 weeks and 12 weeks. According to grouping time, each aneurysm together with stented arteries was removed with animals alive for histopathological examination. Enumeration data was analyzed by Fisher's Exact Test using SPSS 10.0. Results: Before stent placement, angiography of the common carotid arteries showed round, saccular side-wall aneurysms and complex pattern of flow. Immediately after stent placement the aneurysmal pouches were no longer visible and the stented common carotid arteries remained widely patent. All controlled aneurysms and common carotid arteries have been patent and unchanged for 1 year. 13 of 14 stented common carotid arteries with BM-SSS and 3 of 12 with PUM-SSS remained widely patent. The complete patency rate of BM-SSS and PUM-SSS was significantly different (P=0.0008). Histological analysis indicated that all treated aneurysmal pouches were almost filled with thrombus, as well as with fibrotic reactive scar tissue. Stent wires were found to be located deep within the vessel wall and encased by an extension of the tunica intima. The endothelium of the two groups was already mature at 12 weeks, and various degree of degenerate cells were seen under the transmission electron microscopy. Conclusion

  9. AUTOCLAVABLE HIGHLY CROSS-LINKED POLYURETHANE NETWORKS IN OPHTHALMOLOGY

    NARCIS (Netherlands)

    BRUIN, P; MEEUWSEN, EAJ; VANANDEL, MV; WORST, JGF; PENNINGS, AJ

    1993-01-01

    Highly cross-linked aliphatic polyurethane networks have been prepared by the bulk step reaction of low molecular weight polyols and hexamethylenediisocyanate (HDI). These polyurethane networks are optically transparent, colourless and autoclavable amorphous glassy thermosets, which are suited for

  10. New research progress of vegetable oil-based polyurethanes

    Directory of Open Access Journals (Sweden)

    Hongjie LIU

    2016-10-01

    Full Text Available This paper summarizes the latest progress for vegetable oil-based polyurethanes mainly from the view of thermoset and thermoplastic. Firstly, the modification methods for traditional thermoset polyurethane are introduced, including physical modification methods (filling and alloying and chemical modification methods (copolymerization grafting, crosslinking and interpenetrating polymer network. Materials used for physical modification mainly contain inorganic materials such as SiO2 and organic substances such as cellulose. Grafting copolymerization of styrene, acrylate and other monomers with polyurethane is the main method of chemical modification. The characteristics, preparations and application fields of thermoplastic polyurethane are reviewed, and the preparations, performances and applications of oleic acid-based thermoplastic polyurethane are chiefly presented. The development prospects of vegetable oil-based polyurethane are put forward. Surface-initiated living polymerization and other methods are used to controllable chemical modification of the traditional thermoset polyurethane and click chemistry method is uesd to promote multi-functionalization of the thermoplastic polyurethane.

  11. Evaluating Stent Optimisation Technique (StentBoost®) in a Dedicated Bifurcation Stent (the Tryton™)

    International Nuclear Information System (INIS)

    Fysal, Zamil; Hyde, Thomas; Barnes, Edward; McCrea, William; Ramcharitar, Steve

    2014-01-01

    Background/Purpose: To evaluate the use of StentBoost® in the Tryton™ dedicated SideBranch Stent. Methods and Results: The Tryton™ SideBranch Stent has been effectively used to manage complex bifurcations. However, the paucity of scaffolding in the proximal part of the stent makes it often difficult to visualise under standard radiographic imaging. We set out to evaluate whether by using an augmented radiographic imaging technique it was possible to aid visualisation of the stent. In particular the so call 'wedding ring' band which is crucial to the procedural success. We further evaluated whether it was possible to determine the apposition of the stent at the carina, its coverage and the ability to aid recrossing of the struts closest to the carina as well as the added radiation exposure. Conclusions: StentBoost® was found to be invaluable to the procedural success of the Tryton™ deployment without adding any extra cost to the procedure and with only a 3.7% increase in radiation to the patient. It allowed enhanced visualisation in all cases to aid apposition, recrossing and coverage

  12. Evaluating Stent Optimisation Technique (StentBoost®) in a Dedicated Bifurcation Stent (the Tryton™)

    Energy Technology Data Exchange (ETDEWEB)

    Fysal, Zamil; Hyde, Thomas; Barnes, Edward; McCrea, William; Ramcharitar, Steve, E-mail: steve.ramcharitar@chem.ox.ac.uk

    2014-03-15

    Background/Purpose: To evaluate the use of StentBoost® in the Tryton™ dedicated SideBranch Stent. Methods and Results: The Tryton™ SideBranch Stent has been effectively used to manage complex bifurcations. However, the paucity of scaffolding in the proximal part of the stent makes it often difficult to visualise under standard radiographic imaging. We set out to evaluate whether by using an augmented radiographic imaging technique it was possible to aid visualisation of the stent. In particular the so call 'wedding ring' band which is crucial to the procedural success. We further evaluated whether it was possible to determine the apposition of the stent at the carina, its coverage and the ability to aid recrossing of the struts closest to the carina as well as the added radiation exposure. Conclusions: StentBoost® was found to be invaluable to the procedural success of the Tryton™ deployment without adding any extra cost to the procedure and with only a 3.7% increase in radiation to the patient. It allowed enhanced visualisation in all cases to aid apposition, recrossing and coverage.

  13. The rate of symptomatic improvement of congenital nasolacrimal duct obstruction in Japanese infants treated with conservative management during the 1st year of age

    Directory of Open Access Journals (Sweden)

    Hirohiko Kakizaki

    2008-06-01

    Full Text Available Hirohiko Kakizaki1, Yasuhiro Takahashi2, Shinsuke Kinoshita1, Kunihiko Shiraki2, Masayoshi Iwaki11Department of Ophthalmology, Aichi Medical University, Aichi, Japan; 2Department of Ophthalmology and Visual Sciences, Osaka City University Graduate School of Medicine, Osaka, JapanAbstract: This study aimed to examine the rate of symptomatic improvement of congenital nasolacrimal duct obstruction (CNLDO in Japanese infants treated with conservative management within the 1st year of age. Thirty-five lacrimal ducts in 27 patients diagnosed with CNLDO were included in the study. During the observational period, lacrimal ducts were massaged. As well, antibiotic eye drops, to be administered 4 times a day, were sometimes prescribed for obvious conjunctivitis. Two lacrimal ducts in 2 patients were probed before the 1st year of age because of dacryocystitis or severe blepharitis; these patients were included in the unimproved group. Twenty-nine lacrimal ducts in 21 patients resolved during the period (82.9%; with 16 lacrimal ducts resolving before six months of age. Therefore, a comparatively high percentage of resolution for CNLDO (82.9% following conservative management was shown before the 1st year of age in Japanese infants.Keywords: congenital nasolacrimal duct obstruction, symptomatic improvement, conservative management, massage, probing

  14. 40 CFR 721.9959 - Polyurethane polymer (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Polyurethane polymer (generic). 721... Substances § 721.9959 Polyurethane polymer (generic). (a) Chemical substance and significant new uses subject to reporting. (1) The chemical substance identified generically as a polyurethane polymer (PMN P-01...

  15. Influence of polyols on properties of bio-based polyurethanes

    Indian Academy of Sciences (India)

    when compared to the other two polyurethanes PU–PP1 and. PU–PP2. The activation energy (Ea), which is a quantitative mea- sure of thermal stability, associated with each stage of. Table 4. Thermogravimetric analysis data of polyurethanes. Polyurethane. Weight loss at various temperatures (%). Char residue (%) code.

  16. Stenting of major airway constriction

    International Nuclear Information System (INIS)

    Wu Xiaomei

    2002-01-01

    Objective: To investigate the correlated issues in the stenting treatment of major airway constriction. Methods: Nineteen cases of major airway stenting procedure were studied retrospectively. The clinical choice of stents of different advantages or deficiencies were discussed. The importance of intravenous anesthesia supporting, life-parameters monitoring during the procedures and the prevention of complications were analysed. Results: Under intravenous and local anesthesia, 19 Wallstents had been successively placed and relieved 19 cases of major airway constrictions due to malignant or benign diseases (15 of tumors, 3 of tuberculosis, 1 of tracheomalacia). Intravenous anesthesia and life-parameters monitoring had made the procedures more safe and precise. Conclusions: Major airway stenting is an reliable method for relieving tracheobronchial stenosis; and intravenous anesthesia supporting and life-parameters monitoring guarantee the satisfactions of procedures

  17. High Strain Rate Compressive Behavior of Polyurethane Resin and Polyurethane/Al2O3 Hollow Sphere Syntactic Foams

    Directory of Open Access Journals (Sweden)

    Dung D. Luong

    2014-01-01

    Full Text Available Polyurethane resins and foams are finding extensive applications. Seat cushions and covers in automobiles are examples of these materials. In the present work, hollow alumina particles are used as fillers in polyurethane resin to develop closed-cell syntactic foams. The fabricated syntactic foams are tested for compressive properties at quasistatic and high strain rates. Strain rate sensitivity is an important concern for automotive applications due to the possibility of crash at high speeds. Both the polyurethane resin and the syntactic foam show strain rate sensitivity in compressive strength. It is observed that the compressive strength increases with strain rate. The energy absorbed up to 10% strain in the quasistatic regime is 400% higher for the syntactic foam in comparison to that of neat resin at the same strain rate.

  18. Performance of supercritical methanol in polyurethane degradation

    Directory of Open Access Journals (Sweden)

    Liu Lu

    2016-01-01

    Full Text Available Polyurethane is a group of block copolymer which is composed of diisocyanate, chain extender, and polyol, including polyurethane foam, polyurethane elastomer, waterborne polyurethane, etc. This research focused on thermoplastic polyurethane elastomer (TPU which is formed with 4,4’-diphenylmethane diisocyanate (MDI, poly(1,4-butanediol-hexanedioic acid diolpolyester(PBA and extended with 1,4-butanediol(BDO.The degradation of TPU was carried out with the help of methanol as the supercritical solvent. The SEM of the reaction residues revealed the process of the depolymerisation. The products were measured by GC-MS and found out to be PBA, BDO and 4,4’-methylene diphenyl carbamate(MDC which is themethylate of MDI.GC-FID, HPLC-UV and GPC were used to further analysis. The experimental results showed that supercritical methanol performed outstandingly in TPU recycling, it needed lower temperature and shorter time than regular methods. At 230°C/70min, over 90% raw materials of TPU could be recovered.

  19. Use of adjunctive mitomycin C in external dacryocystorhinostomy surgery compared with surgery alone in patients with nasolacrimal duct obstruction: A prospective, double-masked, randomized, controlled trial.

    Science.gov (United States)

    Ari, Seyhmus; Gun, Ramazan; Surmeli, Serdar; Atay, Ahmet Engin; Caca, Ihsan

    2009-08-01

    The most common cause for the failure of external dacryocystorhinostomy (DCR) surgery is the formation of granulation tissue at the osteotomy site or common canaliculus. The aims of this study were to assess the efficacy of intraoperative adjunctive mitomycin C (MMC) treatment in external DCR surgery and to compare this procedure with the standard DCR procedure alone in the long term (1 year). In this prospective, double-masked, randomized, controlled trial, patients with primary acquired nasolacrimal duct obstruction were randomized (using a random number table) into 2 groups based on surgical procedure. In the MMC group, intraoperative adjunctive MMC 0.2 mg/mL was applied to the osteotomy site for 30 minutes. The control group underwent standard DCR procedure only. The results of the DCR surgeries were assessed using objective findings (eg, cessation of excessive tearing via nasolacrimal duct irrigation and the improvement in height of tear meniscus) and subjective symptoms (asking patients to describe the degree of tearing improvement). Both the patients and the researchers who were assessing the study outcomes were masked to treatment group. One hundred eyes of 100 Turkish patients were assessed and equally randomized to the MMC (27 women, 23 men; mean [SD] age, 47.0 [7.6] years) and control (26 women, 24 men; mean age, 46.6 [8.8] years) groups. The follow-up period was not significantly different between the MMC and the control groups (13.1 [1.1] vs 13.2 [1.4] months). Significantly more eyes in the MMC group than the control group remained symptom-free throughout the 1-year follow-up period (45/50 [90%] vs 33/50 [66%]; P=0.005). Significantly more patients in the control group than the MMC group had an improvement in symptoms at the 1-year follow-up (8/50 [16%] vs 2/50 [4%] eyes; P=0.005). Based on the patency of the drainage system, the success rate was significantly greater in the MMC group than the control group (48/50 [96%] vs 42/50 [84%]; P=0.005). Based

  20. Ureteral stents: coil strength and durometer.

    Science.gov (United States)

    Hendlin, Kari; Dockendorf, Kelly; Horn, Christina; Pshon, Nicole; Lund, Brynn; Monga, Manoj

    2006-07-01

    To evaluate the coil strength before and after urine exposure and the stiffness of commercially available double-J ureteral stents because both properties may affect stent performance and patient comfort. Twelve commercially available 6F ureteral stents were tested for coil strength before and after 30 days of urine exposure. The proximal end of each stent was inserted through a 2-mm hole in bologna, allowed to recoil, and then pulled using a handheld force gauge. Ten different commercially available ureteral stent models were tested for tensile strength using an MTS MicroBionix Testing System and Testworks II software and a 5 N load cell. The Cook Black Silicone and Cook C-Flex stents had the strongest coil strengths before urine exposure at 0.480 +/- 0.0 lb (P Circon Double J stent and Bard InLay. Ureteral stents can be differentiated according to their coil strength and stiffness. The impact of these properties on stent performance and patient comfort deserve additional evaluation. The significant variability found in stent stiffness among stents from different lot numbers suggests poor quality assurance in biomaterials or stent processing and increases the complexity of cross-stent comparisons.

  1. Polyurethane Production from Waste Bale Fibers

    Directory of Open Access Journals (Sweden)

    İbrahim BİLİCİ

    2017-12-01

    Full Text Available Nowadays, the methods of eliminating the pollution from wastes of the materials produced as much as the production methods are important. This requires efficiently use of sources economical and ecologically. Polyester based polymers, which is one of the most important consumed plastic materials in the world, have lots of number of recycling methods. Basically it is called chemical and physical recycling. Chemical recycle methods include glycolysis, aminolysis, methanolysis, hydrolysis and etc.. In this study aromatic polyester polyols produced from bale fiber wastes via glycolysis method. Zinc Acetate used as a catalysts and diethylene glycol used for the glycolysis reaction and moiety of glycol investigated as an experimental parameter. Polyurethane material produced via obtained polyol and TDI (Toluene di Isocyanate reaction. Obtained polyurethane material investigated via FTIR and TGA and compared with the commercial polyurethane. As a result, it has been decided that glycolysis is usable and applicable method for the waste bale fibers.

  2. Stent migration after right ventricular outflow tract stenting in the severe cyanotic Tetralogy of Fallot case

    Directory of Open Access Journals (Sweden)

    Tamaki Hayashi

    2017-01-01

    Full Text Available We report our experience with a stent migration after right ventricle outflow tract stenting and converted to patent ductus arteriosus stenting in Tetralogy of Fallot (TOF with severe infundibular stenosis. Finally, the patient achieved to TOF repair, and the migrated stent was removed without any complication.

  3. Biobased polyurethanes prepared from different vegetable oils.

    Science.gov (United States)

    Zhang, Chaoqun; Madbouly, Samy A; Kessler, Michael R

    2015-01-21

    In this study, a series of biobased polyols were prepared from olive, canola, grape seed, linseed, and castor oil using a novel, solvent/catalyst-free synthetic method. The biobased triglyceride oils were first oxidized into epoxidized vegetable oils with formic acid and hydrogen peroxide, followed by ring-opening reaction with castor oil fatty acid. The molecular structures of the polyols and the resulting polyurethane were characterized. The effects of cross-linking density and the structures of polyols on the thermal, mechanical, and shape memory properties of the polyurethanes were also investigated.

  4. Shape memory polyurethane nanocomposites with functionalized graphene

    International Nuclear Information System (INIS)

    Choi, Jin Taek; Dao, Trung Dung; Oh, Kyung Min; Lee, Hyung-il; Jeong, Han Mo; Kim, Byung Kyu

    2012-01-01

    The roles of graphene in shape memory polyurethane nanocomposite (SMPUN) as a reinforcing filler, as a fixed structure for memorizing a specified original shape, and as a conductive filler to actuate shape recovery by resistive heating, were examined. The effectiveness of each role was modulated by functionalizing graphene with a hydroxyl group through oxidation with H 2 O 2 . The reinforcing effect of graphene and its role as a fixed structure were enhanced by the hydroxyl groups due to the increased grafting of polyurethane chains on graphene during the in situ preparation of SMPUN. However, the oxidation reduced the conductivity of SMPUN, resulting in deterioration of the resistive heating. (paper)

  5. Study of polyurethanes ageing offshore

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Fabio G.; Sheldrake, Terry; Clevelario, Judimar; Pires, Fabio [Wellstream International, Panama City, FL (United States); Coutinho, Fernanda M.B. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)

    2008-07-01

    The oil industry is one of the sectors with the highest number of production systems employing high technology. Brazil is worldwide renowned as a leader in oil and gas extraction in deep and ultra deep water. Inside the production chain, a great part the oil and gas produced is conveyed through flexible pipelines that connect the production wells to the platforms. There are two segments of these lines that receive different names according to their application characteristics. When the pipes are laid on the seabed in a static service condition, are called Flow lines and when they raise from the seabed to the platform in a dynamic service condition, are called Risers. The pipes designed for dynamic applications are equipped with Bend Stiffeners, components with conical form and in general with urethane basis, which has the function of providing a smooth stiffness transition between the flexible structure of the pipes and an extremely rigid structure, the platform, not allowing that this component infringes their minimum operation Bend Radius. According to Caire, the proper compression of curvature stiffeners and the material used in its manufacture is becoming increasingly important in industry due to its growing use and the occurrence of failures that have been recorded in recent years. This paper discusses the changes in the mechanical properties of polyurethanes by the hydrolysis during accelerated ageing, reaction of water with functional groups of the polymer chain, as well as mass variation, considering that these materials are designed for a service life exceeding twenty years for operation in water. (author)

  6. Endoscopic stent placement throughout the gastrointestinal tract

    NARCIS (Netherlands)

    van den Berg, M.W.

    2014-01-01

    In this thesis we focussed our research on stent placement throughout the GI tract. In search for ideal stents for treatment of malignant oesophageal stenosis and gastric outlet obstruction we evaluated new stent designs in prospective cohort studies. Smaller research projects mainly aimed to

  7. Therapies targeting inflammation after stent implantation.

    Science.gov (United States)

    Okura, Hiroyuki; Takagi, Tsutomu; Yoshida, Kiyoshi

    2013-07-01

    Since the introduction of coronary vessel scaffold by metallic stent, percutaneous coronary intervention has become widely performed all over the world. Although drug-eluting stent technology has further decrease the incidence of in-stent restenosis, there still remaining issues related to stent implantation. Vessel inflammation is one of the causes that may be related to stent restenosis as well as stent thrombosis. Therefore, systemic therapies targeting inflammation emerged as adjunctive pharmacological intervention to improve outcome. Statins, corticosteroids, antiplatelets, and immunosuppresive or anti-cancer drugs are reported to favorably impact outcome after bare-metal stent implantation. In type 2 diabetic patients, pioglitazone may be the most promising drug that can lower neointimal proliferation and, as a result, lower incidence of restenosis and target lesion revascularization. On the other hand, several new stent platforms that might decrease inflammatory response after drug-eluting stent implantation have been introduced. Because durable polymer used in the first generation drug-eluting stents are recognized to be responsible for unfavorable vessel response, biocompatible or bioabsorbable polymer has been introduce and already used clinically. Furthermore, polymer-free drug-eluting stent and bioresorbable scaffold are under investigation. Although vessel inflammation may be reduced by using these new drug-eluting stents or scaffold, long-term impact needs to be investigated further.

  8. Incidence and predictors of coronary stent thrombosis

    DEFF Research Database (Denmark)

    D'Ascenzo, Fabrizio; Bollati, Mario; Clementi, Fabrizio

    2013-01-01

    Stent thrombosis remains among the most feared complications of percutaneous coronary intervention (PCI) with stenting. However, data on its incidence and predictors are sparse and conflicting. We thus aimed to perform a collaborative systematic review on incidence and predictors of stent...... thrombosis....

  9. Plastic biliary stents for malignant biliary diseases

    NARCIS (Netherlands)

    Huibregtse, Inge; Fockens, Paul

    2011-01-01

    Plastic biliary endoprostheses have not changed much since their introduction more than 3 decades ago. Although their use has been challenged by the introduction of metal stents, plastic stents still remain commonly used. Much work has been done to improve the problem of stent obstruction but

  10. Nonwoven glass fiber mat reinforces polyurethane adhesive

    Science.gov (United States)

    Roseland, L. M.

    1967-01-01

    Nonwoven glass fiber mat reinforces the adhesive properties of a polyurethane adhesive that fastens hardware to exterior surfaces of aluminum tanks. The mat is embedded in the uncured adhesive. It ensures good control of the bond line and increases the peel strength.

  11. Development of Lignin-Based Polyurethane Thermoplastics

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Tomonori [ORNL; Perkins, Joshua H [ORNL; Jackson, Daniel C [ORNL; Trammell, Neil E [ORNL; Hunt, Marcus A [ORNL; Naskar, Amit K [ORNL

    2013-01-01

    In our continued effort to develop value-added thermoplastics from lignin, here we report utilizing a tailored feedstock to synthesize mechanically robust thermoplastic polyurethanes at very high lignin contents (75 65 wt %). The molecular weight and glass transition temperature (Tg) of lignin were altered through cross-linking with formaldehyde. The cross-linked lignin was coupled with diisocyanate-based telechelic polybutadiene as a network-forming soft segment. The appearance of two Tg s, around 35 and 154 C, for the polyurethanes indicates the existence of two-phase morphology, a characteristic of thermoplastic copolymers. A calculated Flory-Huggins interaction parameter of 7.71 also suggests phase immiscibility in the synthesized lignin polyurethanes. An increase in lignin loading increased the modulus, and an increase in crosslink-density increased the modulus in the rubbery plateau region of the thermoplastic. This path for synthesis of novel lignin-based polyurethane thermoplastics provides a design tool for high performance lignin-based biopolymers.

  12. The reactive extrusion of thermoplastic polyurethane

    NARCIS (Netherlands)

    Verhoeven, Vincent Wilhelmus Andreas

    2006-01-01

    The objective of this thesis was to increase the understanding of the reactive extrusion of thermoplastic polyurethane. Overall, several issues were identified: • Using a relative simple extrusion model, the reactive extrusion process can be described. This model can be used to further investigate

  13. Measuring Rind Thickness on Polyurethane Foam

    Science.gov (United States)

    Johnson, C.; Miller, J.; Brown, H.

    1985-01-01

    Nondestructive test determines rind thickness of polyurethane foam. Surface harness of foam measured by Shore durometer method: hardness on Shore D scale correlates well with rind thickness. Shore D hardness of 20, for example, indicates rind thickness of 0.04 inch (1 millimeter). New hardness test makes it easy to determine rind thickness of sample nondestructively and to adjust fabrication variables accordingly.

  14. Comparison of environmentally friendly, selective polyurethane catalysts

    Czech Academy of Sciences Publication Activity Database

    Strachota, Adam; Strachotová, Beata; Špírková, Milena

    2008-01-01

    Roč. 23, č. 6 (2008), s. 566-570 ISSN 1042-6914 R&D Projects: GA MPO FT-TA3/034 Institutional research plan: CEZ:AV0Z40500505 Keywords : amine catalyst * foam * gelation * kinetics * polyurethane Subject RIV: CD - Macromolecular Chemistry Impact factor: 0.706, year: 2008

  15. Polyurethane elastomers made from linear polybutadiene diols

    Czech Academy of Sciences Publication Activity Database

    Špírková, Milena

    2002-01-01

    Roč. 85, č. 1 (2002), s. 84-91 ISSN 0021-8995 R&D Projects: GA AV ČR KSK2050602 Institutional research plan: CEZ:AV0Z4050913 Keywords : polyurethanes * polybutadiene diol * isocyanurate groups Subject RIV: CD - Macromolecular Chemistry Impact factor: 0.927, year: 2002

  16. Flexible optical fiber sensor based on polyurethane

    DEFF Research Database (Denmark)

    Kaysir, Md Rejvi; Stefani, Alessio; Lwin, Richard

    Polyurethane (PU) based hollow core fibers are investigated as optical sensors. The flexibility of PU fibers makes it suitable for sensing mechanical perturbations. We fabricated a PU fiber using the fiber drawing method, characterized the fiber and experimentally demonstrated a simple way...

  17. Thermal Expansion of Polyurethane Foam

    Science.gov (United States)

    Lerch, Bradley A.; Sullivan, Roy M.

    2006-01-01

    Closed cell foams are often used for thermal insulation. In the case of the Space Shuttle, the External Tank uses several thermal protection systems to maintain the temperature of the cryogenic fuels. A few of these systems are polyurethane, closed cell foams. In an attempt to better understand the foam behavior on the tank, we are in the process of developing and improving thermal-mechanical models for the foams. These models will start at the microstructural level and progress to the overall structural behavior of the foams on the tank. One of the key properties for model characterization and verification is thermal expansion. Since the foam is not a material, but a structure, the modeling of the expansion is complex. It is also exacerbated by the anisoptropy of the material. During the spraying and foaming process, the cells become elongated in the rise direction and this imparts different properties in the rise direction than in the transverse directions. Our approach is to treat the foam as a two part structure consisting of the polymeric cell structure and the gas inside the cells. The polymeric skeleton has a thermal expansion of its own which is derived from the basic polymer chemistry. However, a major contributor to the thermal expansion is the volume change associated with the gas inside of the closed cells. As this gas expands it exerts pressure on the cell walls and changes the shape and size of the cells. The amount that this occurs depends on the elastic and viscoplastic properties of the polymer skeleton. The more compliant the polymeric skeleton, the more influence the gas pressure has on the expansion. An additional influence on the expansion process is that the polymeric skeleton begins to breakdown at elevated temperatures and releases additional gas species into the cell interiors, adding to the gas pressure. The fact that this is such a complex process makes thermal expansion ideal for testing the models. This report focuses on the thermal

  18. A Dual Chamber Stent Prevents Organ Malperfusion in a Model of Donation after Cardiac Death

    Science.gov (United States)

    Tillman, Bryan W.; Chun, Youngjae; Cho, Sung Kwon; Chen, Yanfei; Liang, Nathan; Maul, Timothy; Demetris, Anthony; Gu, Xinzhu; Wagner, William R.; Tevar, Amit D.

    2016-01-01

    Background The paradigm for Donation after Cardiac Death (DCD) subjects donor organs to significant ischemic injury. A dual-chamber Organ Perfusion Stent (OPS) would maintain organ perfusion without impacting natural cardiac death. A center lumen allows uninterrupted cardiac blood flow, while an external chamber delivers oxygenated blood to the visceral vessels. Methods A prototype OPS was constructed from commercial stents. In a porcine model, the OPS was deployed, followed by a simulated agonal period. Oxygenated blood perfused the external stent chamber. Organ perfusion was compared between controls (n=3) and OPS (n=6). Finally, a custom nitinol dual chamber OPS was fabricated using a retrievable “petal and stem” design. Results Endovascular OPS deployment achieved visceral isolation without adverse impact on cardiac parameters. Visceral oxygen delivery was 4.8 fold higher as compared to controls. During the agonal period, organs in OPS treated animals appeared well perfused, contrasting to malperfused controls. A custom nitinol and polyurethane OPS was easily recaptured with simple sheath advancement. Conclusions An OPS maintained organ perfusion during the agonal phase in a model of DCD organ donation without adversely impacting cardiac function. Ultimately, the custom retrievable design of this study may help resolve the critical shortage of donor organs for transplant. PMID:27524434

  19. Biodegradable polyurethane nanocomposites containing dexamethasone for ocular route

    International Nuclear Information System (INIS)

    Rodrigues da Silva, Gisele; Silva-Cunha, Armando da; Behar-Cohen, Francine; Ayres, Eliane; Orefice, Rodrigo L.

    2011-01-01

    The treatment of posterior segment ocular diseases, such as uveitis, by using eye drops and oral drugs is usually not effective due to the body's natural barriers to drug penetration. In this study, ocular implants to treat uveitis were synthesized by incorporating dexamethasone acetate, an important type of corticoid used in the treatment of some uveitis, into a biodegradable polyurethane containi clay nanoparticles. Biodegradable polyurethane nanocomposites having poly(caprolactone) oligomers as soft segments were obtained by delaminating clay particles within a polyurethane aqueous dispersion. The drug was incorporated into the polymer by dispersing it in the waterborne polyurethane followed by a drying step. Nanoparticles derived from clay were demonstrated to be able to tailor the mechanical properties of polyurethanes to achieve values that can match the properties of ocular soft tissues. Infrared spectra (FTIR) showed that the presence of clay particles was able to change the microphase separation process typical of polyurethanes. X-ray diffraction and small angle x-ray scattering (SAXS) results were explored to show that the incorporation of both dexamethasone acetate and nanocomponents derived from clay led to a less defined two-phase polyurethane. The presence of clay nanoparticles increased the rate of drug release measured in vitro. Human retinal pigment epithelial cells (ARPE-19) were cultured in contact with polyurethanes and polyurethane nanocomposites, and the viability of them (evaluated by using MTT assay after 7 days) showed that no toxic components were released from polyurethanes containing no drugs during the test.

  20. Indications for stenting during thrombolysis

    DEFF Research Database (Denmark)

    Bækgaard, N; Broholm, R; Just, Sven Richardt Lundgren

    2013-01-01

    . The compression from adjacent structures, predominantly on the left side is known as the iliac vein compression syndrome. Therefore, it is essential that supplementary endovenous procedures have to be performed in case of persistent obstructive lesions following catheter-directed thrombolysis. Insertion...... the challenges in this low-pressure system. The characteristics of the anatomy with external compression and often a curved vein segment with diameter difference make stent placement necessary. Ballooning alone has no place in this area. The proportion of inserted stents varies in the published materials...

  1. Local Delivery of Antiproliferative Agents via Stents

    Directory of Open Access Journals (Sweden)

    Hyuck Joon Kwon

    2014-03-01

    Full Text Available A stent is a medical device for serving as an internal scaffold to maintain or increase the lumen of a body conduit. Stent placement has become a primary treatment option in coronary artery disease for more than the last two decades. The stenting is also currently used for relieving the symptoms of narrowed lumen of nonvascular organs, such as esophagus, trachea and bronchi, small and large intestines, biliary, and urinary tract. Local delivery of active pharmaceutical agents via the stents can not only enhance healing of certain diseases, but it can also help decrease the potential risk of the stenting procedure to the surrounding tissue. In this review, we focus on reviewing a variety of drug-impregnated stents and local drug delivery systems using the stents.

  2. Development of a probucol-releasing antithrombogenic drug eluting stent.

    Science.gov (United States)

    Vedantham, Kumar; Chaterji, Somali; Kim, Sung Won; Park, Kinam

    2012-05-01

    The success of drug eluting stents (DESs) has been challenged by the manifestation of late stent thrombosis after DES implantation. The incomplete regeneration of the endothelial layer poststenting triggers adverse signaling processes precipitating in thrombosis. Various approaches have been attempted to prevent thrombosis, including the delivery of biological agents, such as estradiol, that promote endothelialization, and the use of natural polymers as coating materials. The underlying challenge has been the inability to release the biological agent in synchronization with the temporal sequence of vascular wound healing in vivo. The natural healing process of the endothelium after an injury starts after a week and may take up to a month in humans. This article presents a novel DES formulation using a hemocompatible polyurethane (PU) matrix to sustain the release of probucol (PB), an endothelial agonist, by exploiting the greater difference in the solubility parameters of PB and PU. This results in the formation of crystalline PB aggregates retarding drug release from PU. The physicochemical properties of PB in PU were confirmed using differential scanning calorimetry and X-ray diffraction. Drug-polymer compatibility was examined using infrared spectral analysis. Also, in vitro studies using primary human aortic endothelial cells resulted in the selection of 5% w/w PB as the optimal dose, to be further tested in vitro and in vivo. This work develops and tests a promising new DES formulation to enable faster endothelial cell proliferation poststenting, potentially minimizing the incidence and severity of thrombotic events after DES implantation. Copyright © 2012 Wiley Periodicals, Inc.

  3. Ureteral stenting and urinary stone management: A systematic review

    NARCIS (Netherlands)

    Haleblian, George; Kijvikai, Kittinut; de la Rosette, Jean; Premingert, Glenn

    2008-01-01

    Purpose: Ureteral stents are widely used in many urological procedures. We evaluated the recent literature, providing an update on materials and stent designs, and indications for stent placement and stent complications, including the management of such stent related problems. Materials and Methods:

  4. Retrieval of Migrated Colonic Stents from the Rectum

    International Nuclear Information System (INIS)

    Wholey, Michael H.; Ferral, Hector; Reyes, Ricardo; Lopera, Jorge; Castaneda-Zuniga, Wilfrido; Maynar, Manual

    1997-01-01

    Palliative stenting of malignant colonic obstruction may be complicated by stent migration. Stents that migrate into the rectum cannot be passed with bowel movements and frequently cause obstruction. We present two simple means to retrieve stents from the rectum using fluoroscopic guidance. These techniques were used successfully without complication in four stent migrations

  5. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents

    Directory of Open Access Journals (Sweden)

    Jing Lin

    2016-02-01

    Full Text Available Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  6. Stent malapposition, as a potential mechanism of very late stent thrombosis after bare-metal stent implantation: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Higuma, Takumi, E-mail: higuma@cc.hirosaki-u.ac.jp; Abe, Naoki; Hanada, Kenji; Yokoyama, Hiroaki; Tomita, Hirofumi; Okumura, Ken

    2014-04-15

    A 90-year-old man was admitted to our hospital with acute ST-segment elevation myocardial infarction. He had a history of post-infarction angina pectoris 79 months ago and had a bare-metal stent (BMS) implanted in the proximal left anterior descending artery at our hospital. Emergent coronary angiography demonstrated thrombotic occlusion in the previously stented segment. After catheter thrombectomy, antegrade flow was restored, but 90% stenosis with haziness persisted in the proximal and distal portions of the previously stented segment. Intravascular ultrasound imaging showed interstrut cavities or stent malapposition at the proximal and distal sites of stented segment. In close proximity to the sites, residual thrombi were also observed. Optical coherence tomography (OCT) demonstrated neither lipid-laden neointimal tissue nor rupture but clearly demonstrated residual thrombus adjacent to the malapposed region in addition to the stent malapposition. PCI with balloon was successfully performed and stent apposition was confirmed by OCT. Stent malapposition is an unusual mechanism of very late stent thrombosis after BMS implantation. OCT can clearly reveal the etiology of stent thrombosis.

  7. Circumferential stent fracture repaired using a covered stent in a 42-year-old man with coarctation of the aorta.

    Science.gov (United States)

    Ayoub, Fares; AlShelleh, Sameeha; A L-Ammouri, Iyad

    2016-02-01

    We present a case of circumferential fracture of aortic coarctation stent with severe re-stentosis presenting 16 years after initial stent implantation with end-stage renal disease. The patient was treated with a covered stent using the stent-in-stent technique. The use of an ultra-high-pressure balloon was proved necessary to overcome the tight, non-compliant stenosis.

  8. Rigid Polyurethane Foam Reinforced Coconut Coir Fiber Properties

    OpenAIRE

    Mohd Azham Azmi

    2012-01-01

    This research work studied the properties of composite foam panels. Coconut coir fibers were used as reinforcement in polyurethane (PU) foam in order to increase the properties of foam. This composite foam panels were fabricated by using polyurethane molded method. The polyurethane foam panels reinforced from 5 to 20wt% coconut coir were produced to investigate the physical and mechanical test via density test and three point bending test respectively. It was found that the density test resul...

  9. The Effect of Ethylene Glycol to Soy Polyurethane Foam Classifications

    OpenAIRE

    Flora Elvistia Firdaus

    2012-01-01

    Soy polyol obtained from hydroxylation of soy epoxide with ethylene glycol were prepared as pre-polyurethane. The two step process method were applied in the polyurethane synthesis. The blending of soy polyol with synthetic polyol then simultaneously carried out to TDI (2,4): MDI (4,4-) (80:20), blowing agent, and surfactant. Ethylene glycol were not taking part in the polyurethane synthesis. The inclusion of ethylene glycol were used as a control. Characterization of pol...

  10. Comparison of a New Polytetrafluoroethylene-Covered Metallic Stent to a Noncovered Stent in Canine Ureters

    International Nuclear Information System (INIS)

    Chung, Hwan-Hoon; Lee, Seung Hwa; Cho, Sung Bum; Park, Hong Suk; Kim, Young Sik; Kang, Byung Chul; Frisoli, Joan K.; Razavi, Mahmood K.

    2008-01-01

    The aim of this study was to determine the feasibility of using a newly designed polytetrafluoroethylene (PTFE)-covered metallic stent in the ureter by comparing its effectiveness with that of the noncovered stent in a canine model. We placed 14 stents in the ureters of seven mongrel dogs that weighed 30-40 kg each. The covered and noncovered stents were deployed in the right and left ureters, respectively, of six dogs. In the seventh dog, a covered stent and a double-J catheter were inserted in the right ureter, and a covered stent only was inserted in the left ureter. The first six dogs were sacrificed at 5, 10, and 15 weeks after deployment of the stents (two for each follow-up period), and the seventh dog was sacrificed at 30 weeks. There was no migration or poor expansion of any of the stents observed on plain radiography. On intravenous pyelogram and retrograde pyelogram, all of the covered stents at each follow-up period had patent lumens at the stented segments without hydronephrosis, and the passage of contrast material through it was well preserved. The noncovered stents in the dogs sacrificed at 5 and 10 weeks and one of the two dogs sacrificed at 15 weeks showed near-complete occlusion of the stent lumen due to ingrowth of the soft tissue, and severe hydronephrosis was also noted. The noncovered stent in the other dog sacrificed at 15 weeks showed the passage of contrast material without hydronephrosis, but the lumen of the stent was still nearly occluded by the soft tissue. There was no evidence of hydronephrosis or passage disturbance of the contrast material in both ureters of the dog sacrificed at 30 weeks. We conclude that the newly designed PTFE-covered stent effectively prevented the luminal occlusion caused by urothelial hyperplasia compared to the near-total occlusion of the noncovered stents, and no migration of the covered stents was noted

  11. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types.

    Science.gov (United States)

    Burg, Matthias C; Bunck, Alexander C; Seifarth, Harald; Buerke, Boris; Kugel, Harald; Hesselmann, Volker; Köhler, Michael; Heindel, Walter; Maintz, David

    2011-01-01

    Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid) stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy) were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm) filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results). Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy). 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy) and 6 stents showed poor results (1x nitinol, and 5x 316L). Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  12. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Matthias C. Burg

    2011-01-01

    Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  13. Intravascular Stenting in Microvascular Anastomoses

    DEFF Research Database (Denmark)

    Assersen, Kristine; Sørensen, Jens

    2015-01-01

    Background The effect of intravascular stenting (IVaS) on microvascular anastomoses has given adverse results. For experienced microsurgeons the benefit of IVaS is doubtful. We have investigated the potential benefit of the IVaS technique for two groups of inexperienced microsurgeons with differe...

  14. Palm oil based polyols for acrylated polyurethane production

    International Nuclear Information System (INIS)

    Rida Tajau; Mohd Hilmi Mahmood; Mek Zah Salleh; Khairul Zaman Mohd Dahlan; Rosley Che Ismail

    2006-01-01

    Palm oil becomes important renewable resources for the production of polyols for the polyurethane manufacturing industry. The main raw materials used for the production of acrylated polyurethane are polyols, isocyanates and hydroxyl terminated acrylate compounds. In these studies, polyurethane based natural polymer (palm oil), i.e., POBUA (Palm Oil Based Urethane Acrylate) were prepared from three different types of palm oil based polyols i.e., epoxidised palm oil (EPOP), palm oil oleic acid and refined, bleached and deodorized (RBD) palm olein based polyols. The performances of these three acrylated polyurethanes when used for coatings and adhesives were determined and compared with each other. (Author)

  15. HPSEC Analysis of Ester-Based Polyurethane Rubber Materials

    National Research Council Canada - National Science Library

    Napadensky, Eugene

    2000-01-01

    ... (TACOM) at Picatinny Arsenal, NJ, to evaluate the environmental and operational stability of candidate commercial polyester-polyurethane rubber materials for possible fuel bladder and containment applications...

  16. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  17. Crosslinked polyurethanes based on hyperbranched polymers

    Directory of Open Access Journals (Sweden)

    Vuković Jasna

    2008-01-01

    Full Text Available In this paper, two samples of polyurethane (PU crosslinked with hydroxy -functonal hyperbranched aliphatic polyester of the second pseudo generation were investigated. For the synthesis of these crosslinked PUs two different macrodiols were used: poly(tetramethyleneoxide (PTMO for PUPTMO and ethylene oxide-poly(dimethylsiloxane-ethylene oxide (PDMS-EO for PUPDMS-EO sample. Synthesized samples behave as elastomers and have yellow color. Obtained results show that swelling degree of the sample PUPDMS-EO in N-methyl-2-pyrrolidinon (NMP determined at room temperature is higher than for the sample PUPTMO. It has been also observed that thermal properties of these polyurethane networks can be changed by incorporation of siloxane sequences in their structure.

  18. Thermal stability of soy-based polyurethanes

    Directory of Open Access Journals (Sweden)

    Luciane L. Monteavaro

    2005-06-01

    Full Text Available New types of polyurethanes were prepared by reacting diisocyanates and formiated soy polyols with different OH functionalities. Thermal properties and degradation kinetics were investigated by TGA. All prepared PU's showed at least two-weight loss steps, the first one, around 210 °C. Thermal stability of these PUs depends strongly on urethane groups per unit volume and an increase in the weight loss was observed as a result of the increased amount of urethane groups. Degradation kinetics behavior of the soy-based polyurethanes was investigated according to the Flynn method. Different average activation energy values were obtained from isothermal and isoconversional curves, 140.6 KJ/mol and 62.8 KJ/mol, respectively, indicating the complexity of the PUs degradation process.

  19. Thermoplastic polyurethane as a mechanochromic strain sensor

    Science.gov (United States)

    Cellini, Filippo; Khapli, Sachin; Peterson, Sean D.; Porfiri, Maurizio

    2015-04-01

    Mechanochromism of polymer-dye blends can be used to formulate novel pressure sensors for fluid mechanics and hydrology, where the use of traditional electromechanical transducers may be limited by environmental factors. Here, we investigate optomechanical properties of a mechanochromic blend of thermoplastic polyurethane and 0.5 wt% bis(benzoxazolyl)stilbene fluorescent dye. We characterize the response of this soft active material in a stress relaxation test by simultaneous acquisition of the tensile load, the mechanical deformation, and the fluorescence emission.

  20. Elastic Compositions Based on Polyurethane/ Aliphatic Polyesters

    International Nuclear Information System (INIS)

    Motawie, A.M.; Mazroua, A.M.; Sadek, E.M.; Emam, A.S.; Ramadan, A.M.

    2004-01-01

    Aliphatic polyesters were prepared by melt condensation reaction of a dicarboxylic acid such as adipic and sebacic with different types of diol compounds in 1: 1.1 molar ratio. Ethylene glycol, di-, trio, tetra ethylene glycol and poly( ethylene glycol) with different molecular weights 1000, 4000, 6000 as well as the prepared hydroxy natural rubber were used as diol compounds. Polyurethane, with NCO/OH ratio equal 4, was synthesized from the reaction of toluene diisocyanate with poly(ethylene glycol) 1 000. The prepared polyurethane was mixed with different weight percentages of the prepared aliphatic polyesters. The film samples were tested mechanically, electrically and chemically. The results show that the weight percentage 10% of the added polyadipate or poly sebacate glycols improves flexibility, electrical volume resistivity, dielectric constant and dielectric loss of unmodified rigid polyurethane film sample as well as reduces its swelling by aromatic solvents. All the above mentioned properties improve by increasing the hydrocarbon chain length of the glycol portion in the glycol used and the number of methylene in the aliphatic dicarboxylic acid. Compositions based on hydroxy natural rubber impart better properties than those based on ethylene glycols

  1. Relation of Nickel Allergy with in-Stent Restenosis in Patients Treated with Cobalt Chromium Stents

    OpenAIRE

    Aliağaoğlu, Cihangir; Turan, Hakan; Erden, İsmail; Albayrak, Hülya; Özhan, Hakan; Başar, Cengiz; Gürlevik, Zehra; Alçelik, Ayşegül

    2012-01-01

    Background In-stent restenosis (ISR) is the major limitation of percutaneous coronary stenting procedure. The elements like nickel, chromate and molybdenum are known to cause contact allergy. Hypersensitivity reaction, against these metal ions, may be one of the reasons of ISR. Cobalt chromium coronary stents, which are increasingly being used in percutaneous coronary interventions, have more nickel amount than the stainless steel stents. Objective We aimed to investigate the association betw...

  2. Prevention of stent thrombosis: challenges and solutions

    Science.gov (United States)

    Reejhsinghani, Risheen; Lotfi, Amir S

    2015-01-01

    Stent thrombosis is an uncommon but serious complication which carries with it significant mortality and morbidity. This review analyzes the entity of stent thrombosis from a historical and clinical perspective, and chronicles the evolution of this condition through the various generations of stent development, from bare metal to first-generation, second-generation, and third-generation drug-eluting stents. It also delineates the specific risk factors associated with stent thrombosis and comprehensively examines the literature related to each of these risks. Finally, it highlights the preventative strategies that can be garnered from the existing data, and concludes that a multifactorial approach is necessary to combat the occurrence of stent thrombosis, with higher risk groups, such as patients with ST segment elevation myocardial infarction, meriting further research. PMID:25657588

  3. Biolimus-eluting stents with biodegradable polymer versus bare-metal stents in acute myocardial infarction

    DEFF Research Database (Denmark)

    Räber, Lorenz; Kelbæk, Henning; Taniwaki, Masanori

    2014-01-01

    BACKGROUND: This study sought to determine whether the 1-year differences in major adverse cardiac event between a stent eluting biolimus from a biodegradable polymer and bare-metal stents (BMSs) in the COMFORTABLE trial (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal...

  4. Randomised trial of self-expanding metal stents versus polyethylene stents for distal malignant biliary obstruction

    NARCIS (Netherlands)

    Davids, P. H.; Groen, A. K.; Rauws, E. A.; Tytgat, G. N.; Huibregtse, K.

    1992-01-01

    Self-expanding metal stents are claimed to prolong biliary-stent patency, although no formal comparative trial between plastic and expandable stents has been done. In a prospective randomised trial, we assigned 105 patients with irresectable distal bile-duct malignancy to receive either a metal

  5. Radioactive stents delay but do not prevent in-stent neointimal hyperplasia

    NARCIS (Netherlands)

    I.P. Kay (Ian Patrick); A.J. Wardeh (Alexander); K. Kozuma (Ken); A.H.M. Knook (Marco); A. Thury (Attila); P.W.J.C. Serruys (Patrick); D.P. Foley (David); P.C. Levendag (Peter); W.J. van der Giessen (Wim); G. Sianos (Georgios)

    2001-01-01

    textabstractBACKGROUND: Restenosis after conventional stenting is almost exclusively caused by neointimal hyperplasia. Beta-particle-emitting radioactive stents decrease in-stent neointimal hyperplasia at 6-month follow-up. The purpose of this study was to evaluate the 1-year outcome of (32)P

  6. Angulated Stents-A Novel Stent Improvisation to Manage Difficult Post-tuberculosis Bronchial Stenosis.

    Science.gov (United States)

    Tay, Chee Kiang; Jeong, Byeong-Ho; Kim, Hojoong

    2017-10-18

    Post-tuberculosis bronchostenosis (PTBS), a complication of endobronchial tuberculosis is currently treated by bronchial stenting. However, in cases of angulated bronchial stenoses, difficulty is often encountered in stent insertion and maintenance, resulting in stent migration, granulation tissue overgrowth, and restenosis. To accommodate the angulated alignment of the stenosis, we devised an "angulated stent"-a novel improvisation of the conventional stent via splicing and suturing to achieve a resultant angulated shape. A retrospective review was undertaken to evaluate the performance of this stent. Among 283 PTBS patients who underwent interventional bronchoscopy at our center from 2004 to 2014, 21 were treated with at least one angulated stent. Clinical outcomes, including the stenting duration were investigated. After a median follow-up of 26 months, stent removal was successful in 7 (33.3%) out of 21 patients. In patients managed with angulated stents, the median duration to stent change or eventual removal was longer than those treated with straight tube stents (392 days vs. 86 days; p changing interval.

  7. Peri-stent contrast staining, major evaginations and severe malapposition after biolimus-eluting stent implantation

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Thayssen, Per; Jensen, Lisette Okkels

    2014-01-01

    Peri-stent contrast staining and late acquired malapposition represent pathological vessel wall healing patterns following percutaneous coronary intervention with stent implantation. Earlier studies have described these abnormal vessel wall responses commonly present after implantation of first...... after third-generation biolimus-eluting stent implantation....

  8. Mechanical behavior of peripheral stents and stent-vessel interaction: A computational study

    Science.gov (United States)

    Dottori, Serena; Flamini, Vittoria; Vairo, Giuseppe

    2016-05-01

    In this paper stents employed to treat peripheral artery disease are analyzed through a three-dimensional finite-element approach, based on a large-strain and large-displacement formulation. Aiming to evaluate the influence of some stent design parameters on stent mechanics and on the biomechanical interaction between stent and arterial wall, quasi-static and dynamic numerical analyses are carried out by referring to computational models of commercially and noncommercially available versions of both braided self-expandable stents and balloon-expandable stents. Addressing isolated device models, opening mechanisms and flexibility of both opened and closed stent configurations are numerically experienced. Moreover, stent deployment into a stenotic peripheral artery and possible postdilatation angioplasty (the latter for the self-expandable device only) are simulated by considering different idealized vessel geometries and accounting for the presence of a stenotic plaque. Proposed results highlight important differences in the mechanical response of the two types of stents, as well as a significant influence of the vessel shape on the stress distributions arising upon the artery-plaque system. Finally, computational results are used to assess both the stent mechanical performance and the effectiveness of the stenting treatment, allowing also to identify possible critical conditions affecting the risk of stent fracture, tissue damage, and/or pathological tissue response.

  9. Incidence of definite stent thrombosis or in-stent restenosis after drug-eluting stent implantation for treatment of coronary in-stent restenosis. From western denmark heart registry

    DEFF Research Database (Denmark)

    Jensen, Jesper; Jensen, Lisette Okkels; Terkelsen, Christian Juhl

    2012-01-01

    There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis or resteno......There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis...

  10. Clinical outcomes of secondary gastroduodenal self-expandable metallic stent placement by stent-in-stent technique for malignant gastric outlet obstruction.

    Science.gov (United States)

    Sasaki, Takashi; Isayama, Hiroyuki; Nakai, Yousuke; Takahara, Naminatsu; Hamada, Tsuyoshi; Mizuno, Suguru; Mohri, Dai; Yagioka, Hiroshi; Kogure, Hirofumi; Arizumi, Toshihiko; Togawa, Osamu; Matsubara, Saburo; Ito, Yukiko; Yamamoto, Natsuyo; Sasahira, Naoki; Hirano, Kenji; Toda, Nobuo; Tada, Minoru; Koike, Kazuhiko

    2015-01-01

    To evaluate the efficacy and safety of secondary gastroduodenal stent placement after first stent dysfunction for malignant gastric outlet obstruction. We conducted a retrospective analysis to investigate the efficacy and safety of secondary stent-in-stent gastroduodenal stent placement. Among 260 patients who had been treated with first gastroduodenal stent placement for malignant gastric outlet obstruction, 29 patients (11.2%) were treated with secondary gastroduodenal stent placement because of first stent dysfunction. Pancreatic cancer was the major primary cancer (55.2%). A WallFlex duodenal stent was the most frequently inserted stent both as a first stent (75.9%) and as a secondary stent (62.1%). There were 22 patients (75.9%) that received gastroduodenal stents at the bending site (supraduodenal angle or infraduodenal angle). Technical and clinical success rates were 100% and 86.2%, respectively. Median eating period was 3.0 months, and median survival time was 3.5 months. As for related complications, gastrointestinal perforation, insufficient stent expansion, tumor ingrowth, tumor overgrowth, and cholangitis were experienced in 13.8% (four cases), 6.9% (two cases), 6.9% (two cases), 3.4% (one case), and 3.4% (one case), respectively. Secondary gastroduodenal stent placement might be effective for managing first stent dysfunction in malignant gastric outlet obstruction. However, gastrointestinal perforation was the major complication. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  11. Temporary metal stents in bladder outflow obstruction.

    Science.gov (United States)

    Yachia, D

    1997-12-01

    The use of stents in the management of prostatic obstruction started in 1980 with the development of the "partial catheter" by Fabian in Germany. Since then, a variety of metals and biostable and biodegradable polymers have been made into temporary or permanent stents for the management of infravesical obstructions such as benign or malignant prostatic enlargement, bladder neck stenoses, or urethral strictures. This paper is an overview of two generations of temporary metal stents used in the patients with infravesical obstruction.

  12. Nitinol stent design - understanding axial buckling.

    Science.gov (United States)

    McGrath, D J; O Brien, B; Bruzzi, M; McHugh, P E

    2014-12-01

    Nitinol׳s superelastic properties permit self-expanding stents to be crimped without plastic deformation, but its nonlinear properties can contribute towards stent buckling. This study investigates the axial buckling of a prototype tracheobronchial nitinol stent design during crimping, with the objective of eliminating buckling from the design. To capture the stent buckling mechanism a computational model of a radial force test is simulated, where small geometric defects are introduced to remove symmetry and allow buckling to occur. With the buckling mechanism ascertained, a sensitivity study is carried out to examine the effect that the transitional plateau region of the nitinol loading curve has on stent stability. Results of this analysis are then used to redesign the stent and remove buckling. It is found that the transitional plateau region can have a significant effect on the stability of a stent during crimping, and by reducing the amount of transitional material within the stent hinges during loading the stability of a nitinol stent can be increased. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Functionally active silicones as modifiers of polyurethane textile ...

    African Journals Online (AJOL)

    Modification of application and service properties of polyurethane textile coatings and cast polyurethane films using polysiloxanes (functionally active silicones) have been studied. Experiments were conducted to investigate the effect of silicon additives on processing, adhesion, water repellence, and resistance to tea and ...

  14. Recycling of polyurethane foams: A strategy in waste management ...

    African Journals Online (AJOL)

    ... recycling. of polyurethane post consumer product as a means of waste reduction in our society is still grossly underutilised. This paper examines the current trend in recycling as a means of waste management and focuses on various methods of recycling polyurethane foams considering their application(s) to the Nigerian ...

  15. A kinetic investigation of polyurethane polymerization for reactive extrusion purposes

    NARCIS (Netherlands)

    Verhoeven, VWA; Padsalgikar, AD; Ganzeveld, KJ; Janssen, LPBM

    2006-01-01

    The effects of the reaction conditions on the kinetics of two different polyurethane systems were investigated. To do so, three different kinetic methods were compared: adiabatic temperature rise (ATR), measurement kneader, and high-temperature measurements. For the first polyurethane system,

  16. Fluorinated Polyurethane Scaffolds for 19F Magnetic Resonance Imaging

    NARCIS (Netherlands)

    Lammers, Twan; Mertens, Marianne E.; Schuster, Philipp; Rahimi, Khosrow; Shi, Yang; Schulz, Volkmar; Kuehne, Alexander J.C.; Jockenhoevel, Stefan; Kiessling, Fabian

    2017-01-01

    Researchers used fluorinated polyurethane scaffolds for 19F magnetic resonance imaging. They generated a novel fluorinated polymer based on thermoplastic polyurethane (19F -TPU) which possesses distinct properties rendering it suitable for fluorine-based MRI. The 19F -TPU is synthesized from a

  17. Controlled release of 5-flurouracil from biomedical polyurethanes

    Indian Academy of Sciences (India)

    Administrator

    The release of 5-FU through the microspheres was investigated in pH 7⋅4- phosphate buffer. An increase in release rate was observed with increasing molar ratio of PLF68 with respect to castor oil. Keywords. Biomedical polyurethane; controlled release; 5-flurouracil; drug delivery. 1. Introduction. Polyurethanes are one of ...

  18. Polyurethane nanofibers containing copper nanoparticles as future materials

    DEFF Research Database (Denmark)

    Sheikh, Faheem A.; Kanjwal, Muzafar Ahmed; Saran, Saurabh

    2011-01-01

    In the present study, we aimed to represent a novel approach to fabricate polyurethane nanofibers containing copper nanoparticles (NPs) by simple electrospinning process. A simple method, not depending on additional foreign chemicals, has been employed to utilize prepared copper NPs in polyurethane...

  19. Metallic Stent Expansion Rate at Day One Predicts Stent Patency in Patients with Gastric Outlet Obstruction.

    Science.gov (United States)

    Ye, Bing-Wei; Chou, Chung-Kai; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh; Lee, Kuei-Chuan

    2017-05-01

    Self-expandable metallic stent insertion has been a mainstream treatment for relieving the obstructive symptoms of malignant gastric outlet obstruction (MGOO), a late-stage complication of gastrointestinal malignancies. This study aims to investigate the predictive value of stent expansion rates in clinical outcomes in patients with MGOO. Eighty-seven patients with inoperable MGOO receiving metallic stents were reviewed retrospectively from April 2010 to December 2014. Clinical outcomes, predictors of stent patency, and survival were analyzed. The technical and clinical success rates were 100 and 94.3%, respectively. The median stent patency time was 114 days (range 13-570 days). The median survival time was 133 days (range 13-1145 days). Stent dysfunctions occurred in 28 patients (32.2%), with restenosis accounting for the majority (82%). The stent expansion rate ≥75% at Day 1 predicted the stent patency [hazard ratio (HR) 0.12, P = 0.04]. However, it did not correlate with survival. Non-gastric cancer origins (HR 2.41, P = 0.002) and peritoneal carcinomatosis (HR 2.54, P = 0.001) correlated with poor survival. However, post-stent chemotherapy (HR 0.55, P = 0.03) was related to better outcome. The comparison of clinical outcomes of first and second stent insertions showed no significant difference in the stent expansion rate either at Day 0 and Day 1 (P = 0.97 and P = 0.57). Self-expandable metallic stent insertion is a safe and effective treatment for relieving the obstructive symptoms. The stent expansion rate ≥75% at Day 1 is a novel stent-related predictor of stent patency.

  20. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?

    Science.gov (United States)

    Malina, M; Lindblad, B; Ivancev, K; Lindh, M; Malina, J; Brunkwall, J

    1998-11-01

    To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.

  1. Surface characteristics of chitin-based shape memory polyurethane elastomers.

    Science.gov (United States)

    Zia, Khalid Mahmood; Zuber, Mohammad; Barikani, Mehdi; Bhatti, Ijaz Ahmad; Khan, Mohammad Bilal

    2009-09-01

    Shape memory polyurethanes (SMPUs) were prepared from polycaprolactone diol 4000 (PCL 4000), 1,4-butanediol (BDO), chitin, dimethylol propionic acid (DMPA), triethylamine (TEA) and 4,4'-diphenylmethane diisocyanate (MDI), and the structures of the synthesized materials were verified by infrared spectroscopy. The effects of chitin and DMPA contents in the polyurethane formulation on surface properties were investigated. DMPA provides function of making hydrophilic polyurethanes. The crystalline structure of chitin enhanced the hydrophobicity of the synthesized materials. Contact angle, water absorption, surface free energy, work of water adhesion and swelling behavior of the synthesized polyurethanes were affected by varying the DMPA and chitin contents. The interactions of the PU films with solvents on the surface were clearly related to the contents of DMPA and chitin in the final polyurethane formulation.

  2. Endovascular stent grafting: a review

    International Nuclear Information System (INIS)

    Kribs, S.

    2001-01-01

    Endovascular stent grafts are intravascular devices composed of surgical graft material and a metallic frame, (Fig. 1). Their main application has been to treat aneurysms, but they have been used in vascular trauma and are being investigated for use in occlusive disease. Their advantage in treating aneurysms over conventional surgical treatment is that they are loaded into relatively small delivery systems (Fig. 2) and can be introduced to the area of interest from a remote site - usually the femoral artery. This avoids the morbidity of surgical exposure in difficult sites, such as the thoracic aorta, and lessens the cardiovascular stress to patients by eliminating the need to surgically cross-clamp the vessel being treated. The first description of abdominal aortic aneurysm exclusion by an endovascular stent graft was provided by Parodi and colleagues in 1991. Much of the early clinical experience in endovascular stent grafting was obtained from centres in Australia and Europe, and they are now reporting midterm follow-up data. There are now many centres in Canada and the United States involved in endovascular research and practice. (author)

  3. Biodegradative Activities of Selected Environmental Fungi on a Polyester Polyurethane Varnish and Polyether Polyurethane Foams.

    Science.gov (United States)

    Álvarez-Barragán, Joyce; Domínguez-Malfavón, Lilianha; Vargas-Suárez, Martín; González-Hernández, Ricardo; Aguilar-Osorio, Guillermo; Loza-Tavera, Herminia

    2016-09-01

    Polyurethane (PU) is widely used in many aspects of modern life because of its versatility and resistance. However, PU waste disposal generates large problems, since it is slowly degraded, there are limited recycling processes, and its destruction may generate toxic compounds. In this work, we isolated fungal strains able to grow in mineral medium with a polyester PU (PS-PU; Impranil DLN) or a polyether PU (PE-PU; Poly Lack) varnish as the only carbon source. Of the eight best Impranil-degrading strains, the six best degraders belonged to the Cladosporium cladosporioides complex, including the species C. pseudocladosporioides, C. tenuissimum, C. asperulatum, and C. montecillanum, and the two others were identified as Aspergillus fumigatus and Penicillium chrysogenum The best Impranil degrader, C. pseudocladosporioides strain T1.PL.1, degraded up to 87% after 14 days of incubation. Fourier transform infrared (FTIR) spectroscopy analysis of Impranil degradation by this strain showed a loss of carbonyl groups (1,729 cm(-1)) and N-H bonds (1,540 and 1,261 cm(-1)), and gas chromatography-mass spectrometry (GC-MS) analysis showed a decrease in ester compounds and increase in alcohols and hexane diisocyanate, indicating the hydrolysis of ester and urethane bonds. Extracellular esterase and low urease, but not protease activities were detected at 7 and 14 days of culture in Impranil. The best eight Impranil-degrading fungi were also able to degrade solid foams of the highly recalcitrant PE-PU type to different extents, with the highest levels generating up to 65% of dry-weight losses not previously reported. Scanning electron microscopy (SEM) analysis of fungus-treated foams showed melted and thinner cell wall structures than the non-fungus-treated ones, demonstrating fungal biodegradative action on PE-PU. Polyurethane waste disposal has become a serious problem. In this work, fungal strains able to efficiently degrade different types of polyurethanes are reported, and

  4. Structure and Compatibility Study of Modified Polyurethane/Fe3O4 Nanocomposite for Shape Memory Materials

    Directory of Open Access Journals (Sweden)

    Dick Ferieno Firdaus

    2015-07-01

    Full Text Available Shape Memory Polymer (SMP is one of smart materials class that has the ability to recall a given shape before deformation in the transient state. The development of SMP is dominated by polyurethane which is currently focused on the optimization of manufacturing-related research (ease of processing, and the extraction of the potential for biomedical applications. In this study, Shape Memory Polyurethane (SMPU with Polyethylene Glycol-based material (PEG mw: 6000 as soft segment, 4,4'-Methylenebis (Cyclohexyl isocyanate (HMDI as a hard segment and 1,1,1-Trimethylol propane (TMP as a chain extender were used as a candidate for Vascular Stents. Materials used for the fillers were nano particles of magnetite (Fe3O4 which have 20–50 nm diameters. Variations of the composition were used as a variable. Fourier Transform Infrared Spectroscopy (FTIR and Nuclear Magnetic Resonance (NMR were conducted to investigate the polymer chains which were formed during polymerization, Field Emission Scanning Electron Microscopy (FE-SEM was used to analyze the interface between the filler and the composite matrix. Manual physical actuation was conducted to analyze the physical recovery and transition temperature of the SMPU. Composition and fillers effect on the performance of SMPU composite were discussed in detail along with analysis of its structure and molecular design.

  5. Bioresorbable ureteral stents from natural origin polymers.

    Science.gov (United States)

    Barros, Alexandre A; Rita, Ana; Duarte, C; Pires, Ricardo A; Sampaio-Marques, Belém; Ludovico, Paula; Lima, Estevão; Mano, João F; Reis, Rui L

    2015-04-01

    In this work, stents were produced from natural origin polysaccharides. Alginate, gellan gum, and a blend of these with gelatin were used to produce hollow tube (stents) following a combination of templated gelation and critical point carbon dioxide drying. Morphological analysis of the surface of the stents was carried out by scanning electron microscopy. Indwelling time, encrustation, and stability of the stents in artificial urine solution was carried out up to 60 days of immersion. In vitro studies carried out with simulated urine demonstrated that the tubes present a high fluid uptake ability, about 1000%. Despite this, the materials are able to maintain their shape and do not present an extensive swelling behavior. The bioresorption profile was observed to be highly dependent on the composition of the stent and it can be tuned. Complete dissolution of the materials may occur between 14 and 60 days. Additionally, no encrustation was observed within the tested timeframe. The ability to resist bacterial adherence was evaluated with Gram-positive Staphylococcus aureus and two Gram-negatives Escherichia coli DH5 alpha and Klebsiella oxytoca. For K. oxytoca, no differences were observed in comparison with a commercial stent (Biosoft(®) duo, Porges), although, for S. aureus all tested compositions had a higher inhibition of bacterial adhesion compared to the commercial stents. In case of E. coli, the addition of gelatin to the formulations reduced the bacterial adhesion in a highly significant manner compared to the commercial stents. The stents produced by the developed technology fulfill the requirements for ureteral stents and will contribute in the development of biocompatible and bioresorbable urinary stents. © 2014 Wiley Periodicals, Inc.

  6. Polyurethane networks based on poly (ethylene oxide)

    International Nuclear Information System (INIS)

    Zulfiqar, S.; Quddos, A.

    1993-01-01

    A wide range of infinite urethane polymer networks were prepared from poly (ethylene glycol) (PEG) and hexamethylene disocyanate (HMDI) using 1,1,1, tris (hydroxymethyl) ethane (THME) as crosslinking agent. Differential scanning calorimetry showed that the hydrate formation depends quantitatively upon the weight fraction on poly(ethylene oxide) in the gel. It has been shown that the crosslinked polyurethanes crystallize only with definite ranges of chain length between the knots. In this range with the increase of the degree of crosslinking and crystallinity on the swelling character of the polymeric materials has also been discussed. (author)

  7. Structures and Properties of Polyurethanes. Part II,

    Science.gov (United States)

    1979-03-23

    sharkly pconouuced maximum, that does not make it possible to characterize the aenavior of polyurethane rubbers with the aid of kinetic theory. A cnaue in...of the spin-lattice relaxation of segments to tue sida of high temFeratures in comparison with transition for polyetaec/pclyesters, but this...1523. 265. M ar k J., FIaor y P-J. Amer. Chem. Soc., 1964. 86, 138. 266. M a rt in H., M 6ll1e r E.- Koll. Z., 1960. 42, 991. 267 Mar ve I C., AId r

  8. Shock Wave Structure in Polyurethane Foam

    OpenAIRE

    ONODERA, Hideki; TAKAYAMA, Kazuyoshi

    1994-01-01

    Shock wave propagation in polyurethane (PU(R)) foam was experimentally studied. The experiment was conducted in a shock tube by measuring pressure along the PU(R) foam in a shock tube, by means of holographic interferometry and streak camera recording. It was found that the stress-strain curve of PU(R) has an inflection point. When the pressure behind the incident shock wave was below the inflection-point pressure P_c, the wave impedance ratio of the incident shock wave and transmitted pressu...

  9. Mechanical Characterization of Rigid Polyurethane Foams

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei-Yang [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Mechanics of Materials

    2014-12-01

    Foam materials are used to protect sensitive components from impact loading. In order to predict and simulate the foam performance under various loading conditions, a validated foam model is needed and the mechanical properties of foams need to be characterized. Uniaxial compression and tension tests were conducted for different densities of foams under various temperatures and loading rates. Crush stress, tensile strength, and elastic modulus were obtained. A newly developed confined compression experiment provided data for investigating the foam flow direction. A biaxial tension experiment was also developed to explore the damage surface of a rigid polyurethane foam.

  10. A bioresorbable urethral stent. An experimental study.

    Science.gov (United States)

    Kemppainen, E; Talja, M; Riihelä, M; Pohjonen, T; Törmälä, P; Alfthan, O

    1993-05-01

    The aim of the present study was to examine the suitability of biodegradable polymers as materials for a urethral stent. A new urethral stent made of biodegradable self-reinforced poly-L-lactide (SR-PLLA) was implanted in 16 male rabbits after urethrotomy. Seven stents of stainless steel served as controls. The dimensions of the two types of stents were identical: length 15 mm, diameter 8.2 mm. The mechanical construction was a helical spiral. The SR-PLLA spiral was sustained with three microspirals, and the whole device was coated with DL-lactide to achieve an active initial tissue reaction and better tissue penetration. The SR-PLLA stent showed more favourable implantation properties than the steel one. Within 6 months all PLLA stents had implanted, and the tissue reaction around the stent material was minimal. The helical spiral of stainless steel induced a remarkable inflammatory reaction due to poor implantation properties. We suggest that biodegradable SR-PLLA is a promising material for a urethral stent to prevent re-stenosis of urethral strictures.

  11. Routine intraoperative stenting for renal transplant recipients.

    Science.gov (United States)

    Wilson, Colin H; Bhatti, Aftab A; Rix, David A; Manas, Derek M

    2005-10-15

    Major urological complications (MUCs) after kidney transplantation contribute to patient morbidity and compromise graft function. Ureteric stents have been successfully used to treat such complications and a number of centers have adopted a policy of universal prophylactic stenting, at the time of graft implantation, to reduce the incidence of urine leaks and ureteric stenosis. In conjunction with the Cochrane Renal Group we searched the Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, reference lists of articles, books and abstracts and contacted companies, authors and experts to identify randomized controlled trials examining the use of stents in renal transplantation. The primary outcome was the incidence of MUCs and data on this statistic was pooled and analyzed using a random effects model. Seven randomized controlled trials (1154 patients) of low or moderate quality were identified. The incidence of MUCs was significantly reduced (relative risk [RR] 0.24; 95% CI: 0.07 - 0.77; P=0.02; number needed to treat = 13) by prophylactic ureteric stenting. Urinary tract infections were more common in stented patients (RR 1.49), unless the patients were prescribed 480 mg cotrimoxazole once daily. With this antibiotic regime the incidence of infection was equivalent between the two groups (RR 0.97). Stents appeared generally well tolerated, although trials using longer stents (> or = 20 cm) for longer periods of time (>6 weeks) reported more problems with encrustation and migration. Universal prophylactic stenting reduces the incidence of MUCs and should be recommended on the basis of currently available randomized controlled trials.

  12. Stent placement for esophageal strictures : an update

    NARCIS (Netherlands)

    Hirdes, Meike Madeleine Catharine; Vleggaar, Frank Paul; Siersema, Peter Derk

    2011-01-01

    The use of stents for esophageal strictures has evolved rapidly over the past 10 years, from rigid plastic tubes to flexible self-expanding metal (SEMS), plastic (SEPS) and biodegradable stents. For the palliative treatment of malignant dysphagia both SEMS and SEPS effectively provide a rapid relief

  13. Prevalence of buried probe in complex congenital nasolacrimal duct obstruction and evaluation of its success rate post 'probing and irrigation': a single-centre retrospective study.

    Science.gov (United States)

    Gupta, Nishi; Chawla, Neeraj; Ganesh, Suma; Das, Sima; Dhawan, Nidhi; Bansal, Smriti; Singla, Poonam

    2018-02-05

    The aim of this study was to determine the prevalence of buried probe variant of complex congenital nasolacrimal duct obstruction (CNLDO) and to evaluate the outcome of probing and irrigation in such cases. Institutional review board approval was taken. A total of 309 eyes (258 patients) were diagnosed with CNLDO during the study period of January 2014-March 2017. A retrospective file review of 25 lacrimal systems of 20 patients diagnosed as buried probe variant of complex CNLDO was carried out during the study period. Buried probe variant of complex CNLDO was found to be 8% of the total CNLDO cases during the study period. Mean age at presentation was 1.7 years (range 8-48 months). Discharge and matting of eyelashes were the presenting symptoms in 22 out of 25 (88%) cases, whereas the only epiphora was the presenting symptom in three (12%) cases. Regurgitation of mucopurulent discharge on pressure over lacrimal sac area was positive in 16 out of 25 (64%) eyes. Associated lacrimal and nasal pathologies were seen in six out of 25 cases (24%). Success rate in buried probe variant cases of CNLDO in our study at 3-month follow-up was 88% (22 of 25 cases). A high period prevalence of 8% out of all CNLDO cases in our study suggests that the buried probe should be considered in selective cases of CNLDO and earlier unsuccessful probing.

  14. Atrial septal stenting - How I do it?

    Directory of Open Access Journals (Sweden)

    Kothandam Sivakumar

    2015-01-01

    Full Text Available A wide atrial communication is important to maintain hemodynamics in certain forms of congenital and acquired heart defects. In comparison to balloon septostomy or blade septostomy, atrial septal stenting provides a controlled, predictable, and long-lasting atrial communication. It often needs a prior Brockenbrough needle septal puncture to obtain a stable stent position. A stent deployed across a previously dilated and stretched oval foramen or tunnel form of oval foramen carries higher risk of embolization. This review provides technical tips to achieve a safe atrial septal stenting. Even though this is a "How to do it article," an initial discussion about the indications for atrial septal stenting is vital as the resultant size of the atrial septal communication should be tailored for each indication.

  15. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  16. Structural implications of fenestrated stent graft misalignment.

    Science.gov (United States)

    Crawford, S A; Itkina, M; Doyle, M G; Tse, L W; Amon, C H; Roche-Nagle, G

    2018-04-01

    Endovascular aneurysm repair is a minimally-invasive method for the treatment of abdominal aortic aneurysms. For aneurysms that involve the visceral arteries, a custom-made stent graft with fenestrations for the branch arteries is required. The purpose of the current study is to evaluate the structural impact of misaligned fenestrations with respect to luminal patency and proximal aortic neck apposition in an in vitro model. A custom apparatus was used to evaluate seven Anaconda and three Zenith fenestrated stent grafts. All stent grafts were evaluated at 10° increments of stent/fenestration misalignment up to 80°. Images were captured at each interval and the luminal cross-sectional area and wall apposition were measured. The Anaconda stent graft, which has an unsupported main body, demonstrated a linear reduction in luminal patency at increasing angles of misalignment (P < 0.0001). Stent/fenestration misalignments of 20° and 80° resulted in decreases in mean luminal patency of 14% and 54% respectively. The Zenith stent graft demonstrated a similar decrease in luminal patency, starting at misalignments of ≥40° (P < 0.0001). However, with stent/fenestration misalignments of ≥30°, apposition between the Zenith stent graft and the simulated aortic neck was compromised suggesting the creation of a type Ia endoleak. Both the Anaconda and Zenith devices behave adversely at extreme angles of misalignment with luminal narrowing in the Anaconda device and loss of wall apposition in the Zenith device; however, both stent grafts appear to be equivalent at low angles of misalignment. Copyright © 2016 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  17. Hemolytic effect of deformed intra-arterial stents and stent grafts in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, Jan; Brunn, Hinrich; Heller, Martin; Mueller-Huelsbeck, Stefan [Klinik fuer Diagnostische Radiologie der Christian-Albrecht-Universitaet (CAU) zu Kiel, A. Heller Strasse 9, 24105 Kiel (Germany)

    2003-06-01

    Our objective was to evaluate the hemolytic effect of stents and stent grafts in an in vitro flow model. The model consisted of silicone tubings. Pulsatile flow was delivered at 1170 ml/min. Diluted packed erythrocytes were used (hematocrit of 33%). The Palmaz, MegaLink stents or Passager, Hemobahn stent grafts were placed in the middle portion of the model; control experiments contained no implant (n=10 each). Concentric stenosis of the implant was achieved by constricting the implant to 25, 50, or 70% (area, n=10 each). Samples were drawn at minute 1, 2, 4, 6, 8, 10, 15, and every 10 min up to 1 h. Hemolytic parameters were evaluated. All implants produced hemolysis, increasing in the course of time. Without deformation (0%) the Hemobahn stent causes less hemolysis compared with the other prostheses. At 25% no significant difference could be shown between all devices. At 50% constriction the Palmaz stent caused more hemolysis than the other grafts, and at 70% stenosis the Palmaz and Hemobahn caused more hemolysis than Passager or Megalink. A hemolytic effect was evaluable, probably due to mechanical stress and sheer forces, induced by turbulences in the proximity of the deformed stent. The stent grafts did not perform better than the stents. Differences in the design of a prosthesis and in the degree of stent deformation seem to have an influence on the hemolysis caused. (orig.)

  18. Castor Oil Based Polyurethanes: Synthesis and Characterization

    Science.gov (United States)

    Macalino, AD; Salen, VA; Reyes, LQ

    2017-09-01

    In this study, polyurethanes based on castor oil and 1,6-hexamethylene diisocyanate (HMDI) were synthesized with varying weight ratio of the castor oil and HMDI. The formation of urethane linkages was verified through the use of a fourier transform infrared spectroscopy (FTIR). The hydrophilicity of the films was evaluated through the use of a contact angle meter and it was found that the contact angle of all the films were below 90 degrees which confirms their hydrophilicity. The thermal stability of the PU films were studies through the use of a thermal gravimetric analyzer and found that all of the polyurethane films exhibited two weight loss events at elevated temperatures wherein the first weight loss event was observed to occur at 285°C to 384°C while the second weight loss event was observed at around 521°C to 551°C. The hardness, elastic modulus, and tensile elongation of the PU films were determined by using a universal testing machine (UTM) where it was found out that the hardness and the elastic modulus of the film is directly proportional with HMDI loading while the tensile elongation is inversely proportional to it. Lastly, it was known through the swelling studies of the PU films that it does not swell, this is due to the presence of unreacted triglycerides in the material, which prevents water from permeating to the films.

  19. A review: fabrication of porous polyurethane scaffolds.

    Science.gov (United States)

    Janik, H; Marzec, M

    2015-03-01

    The aim of tissue engineering is the fabrication of three-dimensional scaffolds that can be used for the reconstruction and regeneration of damaged or deformed tissues and organs. A wide variety of techniques have been developed to create either fibrous or porous scaffolds from polymers, metals, composite materials and ceramics. However, the most promising materials are biodegradable polymers due to their comprehensive mechanical properties, ability to control the rate of degradation and similarities to natural tissue structures. Polyurethanes (PUs) are attractive candidates for scaffold fabrication, since they are biocompatible, and have excellent mechanical properties and mechanical flexibility. PU can be applied to various methods of porous scaffold fabrication, among which are solvent casting/particulate leaching, thermally induced phase separation, gas foaming, emulsion freeze-drying and melt moulding. Scaffold properties obtained by these techniques, including pore size, interconnectivity and total porosity, all depend on the thermal processing parameters, and the porogen agent and solvents used. In this review, various polyurethane systems for scaffolds are discussed, as well as methods of fabrication, including the latest developments, and their advantages and disadvantages. Copyright © 2014. Published by Elsevier B.V.

  20. In Vitro and In Vivo Assessment of Docetaxel Formulation Developed for Esophageal Stents.

    Science.gov (United States)

    Shaikh, Mohsin; Zhang, Huihui; Wang, Hongyuan; Guo, Xiuli; Song, Yunmei; Kanwar, Jagat Rakesh; Garg, Sanjay

    2017-01-01

    Esophageal cancer (EC) mostly affects the elderly population and is frequently diagnosed at an advanced stage. Self-expanding metal stents (SEMS) are the most popular mode of palliation, but they are associated with reocclusion caused by tumor growth. To overcome this problem, docetaxel (DTX)-loaded polyurethane formulations were prepared for stent application. The films were evaluated against the cancer cell lines, OE-19 and OE-21, and normal esophageal cell line Het-1A. The DTX and the formulations were evaluated in vitro for the cytotoxicity and in vivo in nude mice. It was found that DTX and the formulations have a weak activity against the EC cell lines and an even weaker activity against Het-1A cell line. Preliminary in vivo studies showed skin toxicity in nude mice necessitating modification of the formulation. Reevaluation in a mouse xenograft model resulted in toxicity at high dose formulations while the low dose formulation exhibited modest advantage over commercial IV formulation; however, there was no significant difference between the commercial IV and blank formulation. DTX combination with an anti-cancer agent having complementary mode of action and non-overlapping toxicity could yield better outcome in future.

  1. Study of the morphology exhibited by linear segmented polyurethanes

    International Nuclear Information System (INIS)

    Pereira, I.M.; Orefice, R.L.

    2009-01-01

    Five series of segmented polyurethanes with different hard segment content were prepared by the prepolymer mixing method. The nano-morphology of the obtained polyurethanes and their microphase separation were investigated by infrared spectroscopy, modulated differential scanning calorimetry and small-angle X-ray scattering. Although highly hydrogen bonded hard segments were formed, high hard segment contents promoted phase mixture and decreased the chain mobility, decreasing the hard segment domain precipitation and the soft segments crystallization. The applied techniques were able to show that the hard-segment content and the hard-segment interactions were the two controlling factors for determining the structure of segmented polyurethanes. (author)

  2. Headache after carotid artery stenting.

    Science.gov (United States)

    Suller Marti, A; Bellosta Diago, E; Velázquez Benito, A; Tejero Juste, C; Santos Lasaosa, S

    2017-04-18

    Headache after carotid artery stenting is a headache with onset during the procedure or in the first few hours after it, and where there is no evidence to suggest a complication of that procedure. The purpose of this study is to describe the main features of these headaches based on our clinical experience. Observational prospective study of a sample of patients undergoing carotid artery stenting at Hospital Clínico Universitario Lozano Blesa, in Zaragoza, Spain. We recorded sociodemographic characteristics, cardiovascular risk factors, carotid artery disease, and history of primary headache; data were gathered using structured interviews completed before and 24hours after the procedure. We included 56 patients (mean age 67±9.52 years); 84% were men. Twelve patients (21.4%) experienced headache, 83.3% of whom were men; mean age was 60.58±9.31 years. Headache appeared within the first 6hours in 7 patients (58.4%) and during the procedure in 4 (33.3%). Pain lasted less than 10minutes in 4 patients (33.3%) and between 10 and 120minutes in 5 (41.7%). Headache affected the frontotemporal area in 7 patients (58.3%); 7 patients (58.3%) described pain as unilateral. It was oppressive in 8 patients (66.7%) and of moderate intensity in 6 (50%). Nine patients (75%) required no analgesics. We found no statistically significant associations with any of the variables except for age (P=.007; t test). In our sample, headache after carotid artery stenting was mild to moderate in intensity, unilateral, oppressive, and short-lasting. Further studies are necessary to gain a deeper knowledge of its characteristics and associated risk factors. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Injected Biodegradable Polyurethane Scaffolds Support Tissue Infiltration and Delay Wound Contraction in a Porcine Excisional Model

    Science.gov (United States)

    Adolph, Elizabeth J.; Guo, Ruijing; Pollins, Alonda C.; Zienkiewicz, Katarzyna; Cardwell, Nancy; Davidson, Jeffrey M.; Guelcher, Scott A.; Nanney, Lillian B.

    2016-01-01

    The filling of wound cavities with new tissue is a challenge. We previously reported on the physical properties and wound healing kinetics of prefabricated, gas-blown polyurethane (PUR) scaffolds in rat and porcine excisional wounds. To address the capability of this material to fill complex wound cavities, this study examined the in vitro and in vivo reparative characteristics of injected PUR scaffolds employing a sucrose porogen. Using the porcine excisional wound model, we compared reparative outcomes to both preformed and injected scaffolds as well as untreated wounds at 9, 13, and 30 days after scaffold placement. Both injected and preformed scaffolds delayed wound contraction by 19% at 9 days and 12% at 13 days compared to non-treated wounds. This stenting effect proved transient since both formulations degraded by day 30. Both types of scaffolds significantly inhibited the undesirable alignment of collagen and fibroblasts through day 13. Injected scaffolds were highly compatible with sentinel cellular events of normal wound repair cell proliferation, apoptosis, and blood vessel density. The present study provides further evidence that either injected or preformed PUR scaffolds facilitate wound healing, support tissue infiltration and matrix production, delay wound contraction, and reduce scarring in a clinically relevant animal model, which underscores their potential utility as a void-filling platform for large cutaneous defects. PMID:26343927

  4. Preparation and antifouling property of polyurethane film modified by chondroitin sulfate

    Science.gov (United States)

    Yuan, Huihui; Xue, Jing; Qian, Bin; Chen, Huaying; Zhu, Yonggang; Lan, Minbo

    2017-02-01

    An antifouling polyurethane film modified by chondroitin sulfate (PU-CS) was prepared by chemical grafting with N-Boc-1,3-propanediamine as a spacer. The different mass fraction of N-Boc-1,3-propanediamine was investigated to obtain PU-CS films with different CS grafting density. The surface properties of PU-CS films were comprehensively characterized. Proteins adsorption and glycosaminoglycans adhesion on films were evaluated. Moreover, inorganic salt deposition on film with highest CS grafting density (3.70 μg/cm2) was briefly investigated. The results showed that the increase of CS grafting density improved not only the hydrophilicity but the antifouling performance of films. The best antifouling film reduced the adsorption of fibrinogen (BFG), human serum albumin (HSA) and lysozyme (LYS) by 81.4%, 95.0% and 76.5%, respectively, and the adhesion of chondroitin (CS), heparin (HP) and hyaluronic acid (HA) by 70.6%, 87.4% and 81.3%, respectively. In addition, the co-adsorption of proteins and glycosaminoglycans reduced up to 86.9% and 75.5%, respectively. Changes in inorganic salt deposition after co-adsorption of proteins and glycosaminoglycans on PU-CS(3) suggested that the proteins promoted the inorganic salt deposition, while glycosaminoglycans inhibited the crystal growth. The negatively charged polysaccharides might promote the generation of smaller crystals which could be conducive to provide theoretical and practical guide to develop novel urinary stents with significant anti-encrustation properties.

  5. TOKYO criteria 2014 for transpapillary biliary stenting.

    Science.gov (United States)

    Isayama, Hiroyuki; Hamada, Tsuyoshi; Yasuda, Ichiro; Itoi, Takao; Ryozawa, Shomei; Nakai, Yousuke; Kogure, Hirofumi; Koike, Kazuhiko

    2015-01-01

    It is difficult to carry out meta-analyses or to compare the results of different studies of biliary stents because there is no uniform evaluation method. Therefore, a standardized reporting system is required. We propose a new standardized system for reporting on biliary stents, the 'TOKYO criteria 2014', based on a consensus among Japanese pancreatobiliary endoscopists. Instead of stent occlusion, we use recurrent biliary obstruction, which includes occlusion and migration. The time to recurrent biliary obstruction was estimated using Kaplan-Meier analysis with the log-rank test. We can evaluate both plastic and self-expandable metallic stents (uncovered and covered). We also propose specification of the cause of recurrent biliary obstruction, identification of complications other than recurrent biliary obstruction, indication of severity, measures of technical and clinical success, and a standard for clinical care. Most importantly, the TOKYO criteria 2014 allow comparison of biliary stent quality across studies. Because blocked stents can be drained not only using transpapillary techniques but also by an endoscopic ultrasonography-guided transmural procedure, we should devise an evaluation method that includes transmural stenting in the near future. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  6. Nanotechnology-based gene-eluting stents.

    Science.gov (United States)

    Goh, Debbie; Tan, Aaron; Farhatnia, Yasmin; Rajadas, Jayakumar; Alavijeh, Mohammad S; Seifalian, Alexander M

    2013-04-01

    Cardiovascular disease is one of the major causes of death in the world. Coronary stenting in percutaneous coronary intervention (PCI) has revolutionized the field of cardiology. Coronary stenting is seen as a less invasive procedure compared to coronary artery bypass graft (CABG) surgery. Two main types of stents currently exist in the market: bare-metal stents (BMS) and drug-eluting stents (DES). DES were developed in response to problems associated with BMS use, like neointimal hyperplasia leading to restenosis. However, the use of DES engendered other problems as well, like late stent thrombosis (ST), which is a serious and lethal complication. Gene-eluting stents (GES) have recently been proposed as a novel method of circumventing problems seen in BMS and DES. Utilizing nanotechnology, sustained and localized delivery of genes can mitigate problems of restenosis and late ST by accelerating the regenerative capacity of re-endothelialization. Therefore this review seeks to explore the realm of GES as a novel alternative to BMS and DES, and its potential implications in the field of nanotechnology and regenerative medicine.

  7. [Metallic ureteral stents. Present and future.

    Science.gov (United States)

    Morcillo, E; Fernández, I; Pamplona, M; Sánchez-Margallo, F M; Soria, F

    2016-10-01

    The management of ureteral obstruction of malignant origin or complicated benign obstruction continues to be a challenge for the urological community. In this sense, the use of metallic stents could be considered a useful alternative to the conventional drainage techniques, because it accomplishes the resolution of obstruction in a single procedure, without external diversions and without the adverse effects of current diversions. Another important advantage they offer is that they do not need replacement as frequently as double J catheters or nephrostomy tubes require. From their first applications in the upper urinary tract until now the design of metallic stents has experienced a notable evolution. The main obstacle at the beginning was the use of stents intended for other organic territories, which caused a high rate of failures, since they did not take into consideration in their designs the hostile environment represented by urine for this type of devices, neither the existence of ureteral peristaltism. Thanks to subsequent metallic designs (Memokath, Uventa, Allium Medical URS-stent, Resonance), the current generation of ureteral metallic stents has improved the success rate in comparison to classical designs, accommodating to ureteral dynamics and improving the coating and alloys. Despite these advances, today, their application is limited to very selected patients due to the onset of undesirable effects still associated with theses stents, such as obstructive urothelial hyperplasia, encrustation or migration. The precise knowledge of the physiopathological mechanisms responsible for the cited adverse effects, together with the application of Bioengineering enabling the development of drug eluting metallic stents, biocoated stents, or new biodegradable metallic materials that mitigate or diminish their effects, may be the key to allow the development of the ideal metallic stent.

  8. Uncertainty Analysis of Decomposing Polyurethane Foam

    Science.gov (United States)

    Hobbs, Michael L.; Romero, Vicente J.

    2000-01-01

    Sensitivity/uncertainty analyses are necessary to determine where to allocate resources for improved predictions in support of our nation's nuclear safety mission. Yet, sensitivity/uncertainty analyses are not commonly performed on complex combustion models because the calculations are time consuming, CPU intensive, nontrivial exercises that can lead to deceptive results. To illustrate these ideas, a variety of sensitivity/uncertainty analyses were used to determine the uncertainty associated with thermal decomposition of polyurethane foam exposed to high radiative flux boundary conditions. The polyurethane used in this study is a rigid closed-cell foam used as an encapsulant. Related polyurethane binders such as Estane are used in many energetic materials of interest to the JANNAF community. The complex, finite element foam decomposition model used in this study has 25 input parameters that include chemistry, polymer structure, and thermophysical properties. The response variable was selected as the steady-state decomposition front velocity calculated as the derivative of the decomposition front location versus time. An analytical mean value sensitivity/uncertainty (MV) analysis was used to determine the standard deviation by taking numerical derivatives of the response variable with respect to each of the 25 input parameters. Since the response variable is also a derivative, the standard deviation was essentially determined from a second derivative that was extremely sensitive to numerical noise. To minimize the numerical noise, 50-micrometer element dimensions and approximately 1-msec time steps were required to obtain stable uncertainty results. As an alternative method to determine the uncertainty and sensitivity in the decomposition front velocity, surrogate response surfaces were generated for use with a constrained Latin Hypercube Sampling (LHS) technique. Two surrogate response surfaces were investigated: 1) a linear surrogate response surface (LIN) and 2

  9. New Flexible FR Polyurethane Foams for Energy Absorption Applications Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Development of new polyurethane (PU) insulation foams through a non-toxic environmentally friendly composite approach. Target FR foams will exhibit high heat flow...

  10. Nano-engineered polyurethane resin-modified concrete.

    Science.gov (United States)

    2014-04-01

    The goal of the proposed work is to investigate the application of nano-engineered polyurethane (NEPU) emulsions for latex modified : concrete (LMC). NEPU emulsions are non-toxic, environment friendly, durable over a wide temperature range, provide b...

  11. Soy-based UV resistant polyurethane pultruded composites.

    Science.gov (United States)

    2012-02-01

    Aliphatic polyurethane (PU) nanocomposites were synthesized using organically modified nanoclays. X-Ray diffraction results : confirmed good exfoliation of nanoclay particles in the PU resin system. With the addition of just 1% of nanoclay in the bas...

  12. Experimental Investigation of Polyurethane Camouflage Coating Using Dynamic Mechanical Analysis

    National Research Council Canada - National Science Library

    Crawford, Dawn

    1999-01-01

    .... The current polyurethane solvent-based (SOL) formulation, used as a chemical-agent-resistant camouflage top coat on all military tactical vehicles, was investigated, along with newly developed water-reducible (WR...

  13. The effect of radiosterilization on cytotoxicity of polyurethane film

    Energy Technology Data Exchange (ETDEWEB)

    Sheikh, N. E-mail: nasrinsheikh@hotmail.com

    2003-08-01

    Nowadays a sequence of tests for evaluation of sterilized biomaterial includes an initial set of tests in vitro, both biological (cell culture) and non-biological (mechanical tests). In this paper the cytotoxicity of a sterilized polyurethane film, in order to use as biomaterial, has been investigated. For this purpose NCO-terminated urethane prepolymer in medical quality was synthesized without ingredients beside monomers (polyethylene glycol/castor oil and toluene diisocyanate). The cured prepolymer films were prepared under ambient conditions due to the reaction of free NCO-groups of prepolymer with air moisture. The polyurethane films were sterilized by gamma-ray (25 kGy). The surface structure of sterilized polyurethane film was observed by SEM and compared to that of the unsterilized film. Also, the in vitro interaction of fibroblast cells and sterilized polyurethane film in culture medium containing serum was evaluated in comparison with control samples. Results showed no signs of cell toxicity.

  14. Polyurethane foam for roadway stabilization NH Route 129, Loudon, NH.

    Science.gov (United States)

    2016-12-12

    This report summarizes the evaluation of the performance of polyurethane foam as a method of roadway : stabilization for a rural roadway experiencing substantial frost heaving. : NHDOT is responsible for many roads which have evolved from gravel road...

  15. Stent-assisted angioplasty for intracranial atherosclerosis

    International Nuclear Information System (INIS)

    Nakahara, Toshinori; Sakamoto, Shigeyuki; Hamasaki, Osamu; Sakoda, Katsuaki

    2002-01-01

    We report on two patients with intracranial atherosclerosis of the carotid artery or vertebral artery treated with stent-assisted angioplasty. Both patients have severe intracranial atherosclerosis (>70%) with refractory symptoms despite optimal medical treatment. In both patients, a coronary balloon-expandable stent was successfully placed using a protective balloon technique without procedural complications. The patients were asymptomatic and neurologically intact at a mean clinical follow-up of 13 months. Follow-up angiograms did not show restenosis 3 or 4 months after procedure, respectively. Stent-assisted angioplasty for intracranial atherosclerosis in the elective patient has proven effective, with an acceptable low rate of morbidity and mortality. (orig.)

  16. A modern generation of drug-eluting stents. Focusing on a sirolimus-eluting stent Calypso

    Directory of Open Access Journals (Sweden)

    А. Н. Кудряшов

    2017-04-01

    Full Text Available The review deals with the evolution of interventional coronary procedures and development of the state-of-art coronary stent market. Emphasis in the review is placed on comprehensive analysis of technical characteristics of the world’s most popular coronary stents versus a Russian bioresorbable sirolimus-eluting stent “Calipso”.Received 13 January 2017. Accepted 17 March 2017.Conflict of interest: Kudryashov A.N., Trebushat D.V. are “Angioline” Company employees, the producer of “Kalipso” coronary stent. Kretov E.I. served as executive editor of “Endovascular surgery” section. All other authors declare no conflict of interest.

  17. Forgotten CBD stent (102 months) with stone-stent complex: A case report.

    Science.gov (United States)

    Barai, Varsha; Hedawoo, Jagadish; Changole, Sanjay

    2017-01-01

    Choledocholithiasis is presence of stone in Common bile duct (CBD) which can be treated by endoscopy or surgery [1]. Retained foreign bodies like stents forms a nidus for stone formation resulting in pain, fever, jaundice. 60 years female patient admitted in surgery ward with features of cholangitis with computed tomography showing cholangitic abscess with dilated common bile duct and sludge around stent in situ. Stone was found at proximal end of stent during surgery. Stents may remain without complications or may migrate, and rarely form nidus for stone formation. If kept for long time they lead to bacterial proliferation, biofilm formation and precipitation of calcium bilirubinate presenting as fever, pain, jaundice. Stent-stone complex can be treated endoscopically and surgically [6,7]. As stent can cause stone formation, infection and other complications, timely removal of stent should advised. III-effects of stent in-situ should be explained, record should be maintained [8] and patient should be advised regular follow up and stent removal after 6 weeks. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Antimicrobial polyurethane thermosets based on undecylenic acid: synthesis and evaluation

    OpenAIRE

    Cádiz, V.; Galià, M.; Ronda, J.C.; Lligadas, G.; Bordons, A.; Esteve-Zarzoso, B.; Lluch, C.

    2014-01-01

    10.1002/mabi.201400017 In the present study, plant oil-derived surface-modifiable polyurethane thermosets are presented. Polyol synthesis is carried out taking advantage of thiol-yne photopolymerization of undecylenic acid derivatives containing methyl ester or hydroxyl moieties. The prepared methyl ester-containing polyurethanes allow surface modification treatment to enhance their hydrophilicity and impart antimicrobial activity through the following two steps: i) grafting poly(propylen...

  19. Property of Polyurethane: from Soy-derived Phosphate Ester

    OpenAIRE

    Flora Elvistia Firdaus

    2011-01-01

    Polyurethane foams (PUF) were formed by a chemical reaction of polyol and isocyanate. The polyol was manufactured by ring-opening hydrolysis of epoxidized soybean oil in the presence of phosphoric acid under varying experimental conditions. Other factors in the foam formulation such as water content and surfactant were kept constant. The effect of the amount of solvents, phosphoric acid, and their derivates in the foam formulation on the properties of polyurethane foams w...

  20. Flexible polyurethane foams based on 100% renewably sourced polyols

    OpenAIRE

    Ugarte, L.; Saralegi, A.; Fernández, R.; Martín, L.; Corcuera, M.A.; Eceiza, A.

    2015-01-01

    Since polyol is one of the major components in polyurethane foam synthesis, introducing renewably sourced polyols in the foam formulation leads to materials with high renewable carbon content. A series of flexible polyurethane foams with variations in polyol composition were synthesized with castor oil based Lupranol Balance ® 50 polyether polyol and corn based polytrimethylene ether glycol mixtures. Water was used as the unique and eco-friendly blowing agent. The effect of the relative amoun...

  1. Preparation and Characterization of Fluorinated Hydrophobic UV-Crosslinkable Thiol-Ene Polyurethane Coatings

    Directory of Open Access Journals (Sweden)

    Wenjing Xia

    2017-08-01

    Full Text Available The polyurethane prepolymer terminated with a double bond was synthesized using isophorone diisocyanate (IPDI, hydroxyl terminated polybutadiene (HTPB, 1,4-butanediol (BDO, and 2-hydroxyethyl acrylate (HEA. Then, a series of innovative UV-curable polyurethane coatings were prepared by blending ene-terminated polyurethane, fluoroacrylate monomer, and multifunctional thiol crosslinker upon UV exposure. The incorporation of fluoroacrylate monomer and multifunctional thiols into polyurethane coatings significantly enhanced the hydrophobic property, mechanical property, pencil hardness, and glossiness of the polyurethane coatings. This method of preparing UV crosslinkable, hydrophobic polyurethane coatings based on thiol-ene chemistry exhibited numerous advantages over other UV photocuring systems.

  2. Modeling Decomposition of Unconfined Rigid Polyurethane Foam

    Energy Technology Data Exchange (ETDEWEB)

    CHU,TZE YAO; ERICKSON,KENNETH L.; HOBBS,MICHAEL L.

    1999-11-01

    The decomposition of unconfined rigid polyurethane foam has been modeled by a kinetic bond-breaking scheme describing degradation of a primary polymer and formation of a thermally stable secondary polymer. The bond-breaking scheme is resolved using percolation theory to describe evolving polymer fragments. The polymer fragments vaporize according to individual vapor pressures. Kinetic parameters for the model were obtained from Thermal Gravimetric Analysis (TGA). The chemical structure of the foam was determined from the preparation techniques and ingredients used to synthesize the foam. Scale-up effects were investigated by simulating the response of an incident heat flux of 25 W/cm{sup 2} on a partially confined 8.8-cm diameter by 15-cm long right circular cylinder of foam which contained an encapsulated component. Predictions of center, midradial, and component temperatures, as well as regression of the foam surface, were in agreement with measurements using thermocouples and X-ray imaging.

  3. Modeling Decomposition of Unconfined Rigid Polyurethane Foam

    Energy Technology Data Exchange (ETDEWEB)

    HOBBS,MICHAEL L.; ERICKSON,KENNETH L.; CHU,TZE YAO

    1999-11-08

    The decomposition of unconfined rigid polyurethane foam has been modeled by a kinetic bond-breaking scheme describing degradation of a primary polymer and formation of a thermally stable secondary polymer. The bond-breaking scheme is resolved using percolation theory to describe evolving polymer fragments. The polymer fragments vaporize according to individual vapor pressures. Kinetic parameters for the model were obtained from Thermal Gravimetric Analysis (TGA). The chemical structure of the foam was determined from the preparation techniques and ingredients used to synthesize the foam. Scale-up effects were investigated by simulating the response of an incident heat flux of 25 W/cm{sup 2} on a partially confined 8.8-cm diameter by 15-cm long right circular cylinder of foam that contained an encapsulated component. Predictions of center, midradial, and component temperatures, as well as regression of the foam surface, were in agreement with measurements using thermocouples and X-ray imaging.

  4. Polyurethane elastomers from morphology to mechanical aspects

    CERN Document Server

    Prisacariu, Cristina

    2011-01-01

    A comprehensive account of the physical / mechanical behaviour of polyurethanes (PU´s) elastomers, films and blends of variable crystallinity. Aspects covered include the elasticity and inelasticity of amorphous to crystalline PUs, in relation to their sensitivity to chemical and physical structure. A study is made of how aspects of the constitutive responses of PUs vary with composition: the polyaddition procedure, the hard segment, soft segment and chain extender (diols and diamines) are varied systematically in a large number of systems of model and novel crosslinked andthermoplastic PUs. Results will be related to: microstructural changes, on the basis of evidence from x-ray scattering (SAXS and WAXS), and also dynamic mechanical analyses (DMA), differential scanning calorimetry (DSC) and IR dichroism. Inelastic effects will be investigated also by including quantitative correlations between the magnitude of the Mullins effect and the fractional energy dissipation by hysteresis under cyclic straining, g...

  5. Degradation characteristics of waste polyurethane by radiation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Seok; Ahn, Sung Jun; Gwon Hui Jeong; Jeong, Sung In; Nho, Young Chang; Lim, Youn Mook [Research Division for Industry and Environment, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of)

    2017-06-15

    Polyurethane (PU) is a very popular polymer that is used in a variety of applications due to its good mechanical, thermal, and chemical properties. However, waste PU recycling has received significant attention due to environmental issues. The aim of this work was to investigate the degradation characteristics of waste PU to recycle. Degradation of waste PU was carried out using a radiation techniques. Waste PUs were exposed to a gamma {sup 60}Co sources. To verify degradation, the irradiated PUs were characterized using FT-IR, gel permeation chromatography (GPC), and their thermal/mechanical properties are reported. When the radiation dose was 500 kGy, the molecular weight of the waste PU drastically decreased. Also, the mechanical properties of waste PU were approximately 4 times lower than those of non-irradiated PU. This study has confirmed the possibility of making fine particle of waste PU for recycling through radiation degradation techniques.

  6. Experimental study on hemocompatibility of domestic silicone-covered stent

    International Nuclear Information System (INIS)

    Li Wentao; Wang Jianhua; Liu Qingxin; Qu Xudong

    2005-01-01

    Objective: To evaluate the hemocompatibility of domestic silicone-covered stent in the iliac arteries of canine model. Methods: Eighteen domestic stents were placed in iliac arteries of 9 adult dogs after larger balloon PTA, which included 10 silicone-covered stents and 8 bare stents for control. DSA was performed at 1, 4, 12 weeks after stent implantation in the iliac arteries of two groups to observe the outcomes of patency or restenosis. Animals were then euthanized isolating and staining the stented arteries with hematoxylin and eosin for histological examination. Finally, the acute thrombosis, reendothelialization and the neointimal proliferation of both covered and bare stents were quantified on histological cross-section. Results: All bare stents were patent in 12 weeks, but two silicone-covered stents were occluded at 4, 12 week respectively (patent rate was 80%). Stented vascular stenosis rate was averaging 72.3% at 12 week in covered stents and 36.7% in bare stents. Conclusions: The hemocompatibility of silicone-covered stents is not better than that of bare stents. Silicone appears to be inert in this experimental application. (authors)

  7. Synthesis and Characterization of Cellulose Nanofibril-Reinforced Polyurethane Foam

    Directory of Open Access Journals (Sweden)

    Weiqi Leng

    2017-11-01

    Full Text Available In this study, traditional polyol was partially replaced with green, environmentally friendly cellulose nanofibrils (CNF. The effects of CNF on the performance of CNF-reinforced polyurethane foam nanocomposites were investigated using scanning electron microscopy, Fourier transform infrared spectroscopy (FT-IR, X-ray diffraction (XRD analysis, thermogravimetric analysis (TGA, differential scanning calorimetry (DSC, dynamic mechanical analysis (DMA, and a compression test. The results showed that the introduction of CNF into the polyurethane matrix not only created stronger urethane bonding between the hydroxyl groups in the cellulose chain and isocyanate groups in polymethylene polyphenylisocyanate, but also developed an additional filler–matrix interaction between CNF and polyurethane. With the increase of the CNF replacement ratio, a higher glass transition temperature was obtained, and a higher amount of char residue was generated. In addition, an increase of up to 18-fold in compressive strength was achieved for CNF-PUF (polyurethane foam nanocomposites with a 40% CNF replacement ratio. CNF has proved to be a promising substitute for traditional polyols in the preparation of polyurethane foams. This study provides an interesting method to synthesize highly green bio-oriented polyurethane foams.

  8. Hydroxyapatite-silver nanoparticles coatings on porous polyurethane scaffold.

    Science.gov (United States)

    Ciobanu, Gabriela; Ilisei, Simona; Luca, Constantin

    2014-02-01

    The present paper is focused on a study regarding the possibility of obtaining hydroxyapatite-silver nanoparticle coatings on porous polyurethane scaffold. The method applied is based on a combined strategy involving hydroxyapatite biomimetic deposition on polyurethane surface using a Supersaturated Calcification Solution (SCS), combined with silver ions reduction and in-situ crystallization processes on hydroxyapatite-polyurethane surface by sample immersing in AgNO3 solution. The morphology, composition and phase structure of the prepared samples were characterized by scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDX), X-ray diffraction (XRD), UV-Vis spectroscopy and X-ray photoelectron spectroscopy (XPS) measurements. The data obtained show that a layer of hydroxyapatite was deposited on porous polyurethane support and the silver nanoparticles (average size 34.71 nm) were dispersed among and even on the hydroxyapatite crystals. Hydroxyapatite/polyurethane surface acts as a reducer and a stabilizing agent for silver ions. The surface plasmon resonance peak in UV-Vis absorption spectra showed an absorption maximum at 415 nm, indicating formation of silver nanoparticles. The hydroxyapatite-silver polyurethane scaffolds were tested against Staphylococcus aureus and Escherichia coli and the obtained data were indicative of good antibacterial properties of the materials. © 2013.

  9. Polyurethane foam-covered breast implants: a justified choice?

    Science.gov (United States)

    Scarpa, C; Borso, G F; Vindigni, V; Bassetto, F

    2015-01-01

    Even if the safety of the polyurethane prosthesis has been the subject of many studies and professional and public controversies. Nowadays, polyurethane covered implants are very popular in plastic surgery for the treatment of capsular contracture. We have identified 41 papers (1 is a communication of the FDA) by using search browsers such as Pubmed, Medline, and eMedicine. Eleven manuscripts have been used for an introduction, and the remaining thirty have been subdivided into three tables whose results have been summarized in three main chapters: (1) capsular formation and contracture, (2) complications, (3) biodegradation and cancer risk. (1) The polyurethanic capsule is a well defined foreign body reaction characterized by synovial metaplasia, a thin layer of disarranged collagen fibers and a high vascularization. These features make possible a "young" capsule and a low occurrence of capsular contracture even over a long period (10 years); (2) the polyurethane implants may be difficult to remove but there is no evidence that they cause an increase in the other complications; (3) there is no evidence of polyurethane related cancer in long-term studies (after 5 years). Polyurethane foam covered breast implants remain a valid choice for the treatment of capsular contracture even if it would be very useful to verify the ease of removal of the prosthesis and to continue investigations on biodegradation products.

  10. Stenting of Extracranial Carotid Artery Stenosis

    Science.gov (United States)

    Koshimae, N.; Morimoto, T.; Nagata, K.

    2003-01-01

    Summary The purpose of this study is to evaluate our cases of cervical internal carotid artery stenosis for safty stenting. We investigate the preoperative internal carotid artery stenosis using by integrated backscatter (IBS) method of ultra sonography, comparing with the thirty five surgical specimens as to their nature, histological structure, thickness of fibrous cap. We choose the protection method according to plaque structure, and placed Easy-Wall stent or Smart stent after prePTA. We added post PTA according to the extent of expansion and IVUS findings. Calibrated IBS = IBS value (ROI) /intinal IBS value of ‘bleeding’, ‘lipiď, ‘thrombus’, fiber, ‘hyalinization’ were -27.5, -22.5, -15.2, -11.1, +2.1. That of the thin fibrous cap were -10.9*, that of thic fibrous cap were -2.4 (*p safty stenting. PMID:20591243

  11. Angioplasty and stent placement - peripheral arteries

    Science.gov (United States)

    ... blood flow. A stent is a small, metal mesh tube that keeps the artery open. Angioplasty and ... Shreveport, Shreveport, LA. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Medical ...

  12. Angioplasty and stent placement - carotid artery - discharge

    Science.gov (United States)

    ... have also had a stent (a tiny wire mesh tube) placed in the blocked area to keep ... Stony Brook, NY. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Medical ...

  13. Allium stent for treatment of ureteral stenosis.

    Science.gov (United States)

    Leonardo, C; Salvitti, M; Franco, G; De Nunzio, C; Tuderti, G; Misuraca, L; Sabatini, I; De Dominicis, C

    2013-12-01

    The aim of our study is to value the efficacy of self-expanding Allium ureteral stent in the treatment of ureteral stenosis. From 2010 to 2013, we treated 12 patients, aged from 23 to 64 years. Six patients were affected by congenital UPJ obstruction, four patients by iatrogenic unilateral ureteral stenosis and two patients by bilateral ureteral stenosis. All the patients showed hydronephrosis before the stenotic lesion and pain. In all the patients, we use a 30 Fr, 10 cm length self-expanding Allium ureteral stent. The medium follow-up is 10 months after Allium stent removal. All the patients were immediately free of pain after the procedure. We didn't experience intra, peri and postoperative complications. In all the patients, a complete correction of the stenotic lesion was obtained. No recurrence of stenosis occurred during follow-up. Self-expanding allium ureteral stent represents an effective treatment of ureteral stenosis in patients not suitable for surgery.

  14. Bilateral stenting at the iliocaval confluence.

    Science.gov (United States)

    Neglén, Peter; Darcey, Rikki; Olivier, Jake; Raju, Seshadri

    2010-06-01

    This study describes three techniques of stent placement at the iliocaval confluence for chronic nonmalignant obstruction and its stent-related outcome. From 1997 to 2008, 115 patients (230 limbs) underwent bilateral stenting for iliocaval obstruction. All limbs were CEAP classified using clinical examination and duplex ultrasound study. Three techniques were compared: placement of two stents side by side in a "double-barrel" (group DB, n = 39); inverted Y stenting through a fenestra (window) created through the side braiding of a stent placed previously across the iliocaval confluence (group iY, n = 38); apposition of a stent as close as possible to a stent previously placed across the iliocaval confluence, leaving a small area unsupported between the stents (group A, n = 38). Patency was assessed with venography and duplex ultrasound imaging. Cumulative patency curves were calculated. Median age was 54 years (range, 14-76 years); female/male ratio was 2.8:1. Obstructions were primary in 141 limbs and postthrombotic in 89, and 29 required recanalization of occlusions. The C(4-6) rate and ratio of limbs with postthrombotic obstruction were significantly higher in group iY vs group DB (49% and 32% [P = .049]; 47% and 28% [P = .022], respectively). The median follow-up was 12 months (range, 1-108 months) in 107 patients (93%). The overall primary, assisted primary, and secondary patency rates at 4 years were 61%, 92%, and 98%, respectively. The distribution of occluded stent systems (n = 4) and frequency of reinterventions (n = 29) were reflected in the primary and secondary patency rates for groups A, DB, and iY at 4 years (77% and 100%, 73% and 100%, and 41% and 90%, respectively). The frequency of reinterventions was significantly lower in group DB vs groups A and iY (8%, 32%, and 37%, respectively; P iY regardless of etiology of obstruction. However, inverted Y fenestration is the only choice in delayed contralateral stenting or when the inferior vena cava is

  15. Emerging Stent and Balloon Technologies in the Femoropopliteal Arteries

    Directory of Open Access Journals (Sweden)

    Georgios Pastromas

    2014-01-01

    Full Text Available Endovascular procedures for the management of the superficial femoral (SFA and popliteal artery disease are increasingly common. Over the past decade, several stent technologies have been established which may offer new options for improved clinical outcomes. This paper reviews the current evidence for SFA and popliteal artery angioplasty and stenting, with a focus on randomized trials and registries of nitinol self-expanding stents, drug-eluting stents, dug-coated balloons, and covered stent-grafts. We also highlight the limitations of the currently available data and the future routes in peripheral arterial disease (PAD stent and balloon technology.

  16. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    OpenAIRE

    Kensuke Tashiro, MD; Shuji Yamashita, MD; Mitsunaga Narushima, MD; Isao Koshima, MD; Shimpei Miyamoto, MD

    2017-01-01

    Background:. Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined...

  17. Biomimicry, vascular restenosis and coronary stents.

    Science.gov (United States)

    Schwartz, R S; van der Giessen, W J; Holmes, D R

    1998-01-01

    Biomimicry is in its earliest stages and is being considered in the realm of tissue engineering. If arterial implants are to limit neointimal thickening, purely passive structures cannot succeed. Bioactivity must be present, either by pharmacologic intervention or by fabricating a 'living stent' that contains active cellular material. As tissue engineering evolves, useful solutions will emerge from applying this knowledge directly to vascular biologic problems resulting from angioplasty, stenting, and vascular prosthesis research.

  18. Ureteral stent discomfort: Etiology and management

    Directory of Open Access Journals (Sweden)

    Ricardo Miyaoka

    2009-01-01

    Full Text Available Objectives : To review the evidence-based literature on the causes, characteristics, and options to manage double J stent-related symptoms. Methods : We performed a Medline database assessment on papers that investigated the prevalence, mechanisms, risk factors, bothersome and management of double-J stent-related symptoms. Articles in English were reviewed and summarized. Results : Stent-related symptoms have a high prevalence and may affect over 80% of patients. They include irritative voiding symptoms including frequency, urgency, dysuria, incomplete emptying; flank and suprapubic pain; incontinence, and hematuria. Assessment tools are important to determine their intensity and allow for comparisons between different points in the timeline. The Urinary Stent Symptom Questionnaire (USSQ is the most proper tool used for this purpose. Management should be focused on the prevention and management of symptoms. In this sense, research has focused on new materials and stent designs that would be more compatible to the physiologic properties of the urinary tract and medications that can ameliorate the sensitivity and motor response of the bladder. Conclusions : Stent-related symptoms are very common in the Urological clinical setting. It is of major importance for the urologist to understand their physiopathology and to be familiar with ways to avoid or manage them.

  19. Nanoclay Dispersion and its Effect on Properties of Waterborne Polyurethanes

    Directory of Open Access Journals (Sweden)

    H. Honarkar

    2014-01-01

    Full Text Available In recent years, waterborne polyurethanes as in coatings and adhesives formulations have attracted considerable attention because they are non-toxic, non-flammable and friendly to environment. Besides environmental management, the flexibility, low temperature property, high tensile strength, good adhesion and improved rheological property are specific properties of waterborne polyurethanes. Also low production cost of water borne polyurethanes over solvent-borne polyurethanes is also a reason for their applications. However, these materials have some defects such as weak water resistance and low adhesion in the moisture environment due to sensitivity of their hydrophilic ionic bonds, ether groups, urethane and ester groups to hydrolysis which need to be improved. Also, low heat resistance of these materials is due to a relatively low crystalline melting point or glass transition temperature of hard segments. One of the ways to solve this problem and improve its properties for different applications is the addition of inorganic fillers especially nano-sized layered silicates within polyurethane matrix. In this way water resistance, heat resistance, mechanical properties and modulus increase simultaneously. In this research, waterborne polyurethane nanocomposites with PTMG polyol, IPDI, DMPA (internal emulsifier, TEA (neutralizer and 1, 3 and 5weight % of Cloisite 30B as reinforcement were synthesized and characterized. Polarity of the samples was investigated by contact angle test and dispersion of nano particles in the samples was characterized by X-Ray and TEM, Thermal properties and dynamic mechanical properties were measured by TGA and DMTA, respectively. The results showed that incorporation of clay into polyurethanes did reduce water absorption and increased heat resistance, modulus, particle size and contact angle.In recent years, waterborne polyurethanes including coatings and adhesives have attracted considerable attention because they

  20. Mechanical properties of various z-stent designs: an endovascular stent-grafting perspective.

    Science.gov (United States)

    Bashar, Abul Hasan Muhammad; Kazui, Teruhisa; Washiyama, Naoki; Terada, Hitoshi; Yamashita, Katsushi; Haque, Mohammad E

    2003-08-01

    To comparatively assess the mechani-cal behavior of various clinically relevant Z-stent designs. A total of 16 Z-stents of original, biliary, spiral, and double-skirted designs (n=4 for each) were constructed using similar specifications for all. Stents were then evaluated for stiffness, snap opening force (SOF), flexibility, and displacement force using a novel tensiometer. Differences among the stents were determined using statistical methods. Stents explanted from dog aorta after a mean follow-up of 13 months were examined under a scanning electron microscope for surface defects. Forces required for about 50% reduction in diameter were 1.88 +/- 0.16 N, 3.81 +/- 0.21 N, 2.76 +/- 0.22 N, and 3.35 +/- 0.19 N for original, biliary, spiral, and skirted designs, respectively. Differences among the four designs were statistically significant at almost all points of measurement (P designs showed higher SOF values in the early measurements. Stents explanted from dog aorta after a mean duration of 13 months showed no obvious corrosion or breakage in the wire struts. Significant differences exist among the various Z-stent designs in terms of their mechanical properties. Understanding them should help to select the appropriate stent for a given lesion. 316L stainless steel shows a favorable long-term tissue interaction.

  1. A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents

    NARCIS (Netherlands)

    C.M. Spaulding (Christian); J. Daemen (Joost); H. Boersma (Eric); D.E. Cutlip (Donald); P.W.J.C. Serruys (Patrick)

    2007-01-01

    textabstractBACKGROUND: Although randomized studies have shown a beneficial effect of drug-eluting stents in reducing the risk of repeated revascularization, these trials were underpowered to compare rates of death and myocardial infarction. The long-term safety of drug-eluting stents has been

  2. Technical options for treatment of in-stent restenosis after carotid artery stenting

    NARCIS (Netherlands)

    Pourier, Vanessa E C|info:eu-repo/dai/nl/413970310; de Borst, Gert J.|info:eu-repo/dai/nl/237108151

    2016-01-01

    Objective This review summarizes the available evidence and analyzes the current trends on treatments for carotid in-stent restenosis (ISR) after carotid artery stenting (CAS). Methods An update of a 2010 review of the literature (which included 20 articles) was conducted using PubMed and Embase.

  3. Current Trends in Preoperative Biliary Stenting in Pancreatic Cancer Patients

    Science.gov (United States)

    Jinkins, Lindsay J.; Parmar, Abhishek D.; Han, Yimei; Duncan, Casey B.; Sheffield, Kristin M.; Brown, Kimberly M.; Riall, Taylor S.

    2013-01-01

    BACKGROUND Sufficient evidence suggests that preoperative biliary stenting is associated with increased complication rates after pancreaticoduodenectomy. METHODS Surveillance, Epidemiology, and End Results (SEER) and linked Medicare claims data (1992–2007) were used to identify patients with pancreatic cancer who underwent pancreaticoduodenectomy. We evaluated trends in the use of preoperative biliary stenting, timing of physician visits relative to stenting, and time to surgical resection and symptoms in stented and unstented patients. RESULTS Pancreaticoduodenectomy was performed in 2,573 patients. 52.6% of patients underwent preoperative biliary stenting (N=1,354). Of these, 75.3% underwent endoscopic stenting only, 18.9% received a percutaneous stent, and 5.8% underwent both procedures. The overall stenting rate increased from 29.6% of patients in 1992–95 to 59.1% in 2004–07 (pPreoperative stenting was more common in patients with jaundice, cholangitis, pruritus, or coagulopathy (ppreoperative biliary stenting doubled from 1992–2007 despite evidence that stenting is associated with increased perioperative infectious complications. The majority of stenting occurred prior to surgical consultation and is associated with significant delay in time to operation. Surgeons should be involved early in order to prevent unnecessary stenting and improve outcomes. PMID:23889947

  4. New expandable metallic stents: An experimental study in vessels of dogs

    International Nuclear Information System (INIS)

    Song, Ho Young; Lee, Jung Min; Chung, Jin Young; Chung, Gyung Ho; Kim, Bog Yi; Kuh, Ja Houng

    1992-01-01

    Three-types of expandable metallic stents were constructed to evaluate the differences between the stents: one, formed in a cylindrical zigzag pattern wth stainless steel wire (Gianturco stent), another, made by coating the Gianturco stent with silicone rubber (Silicone stent), the third, made by coating the Gianturco stent with 24 carat gold (Gold stent) for tissue acceptance. A total of 69 stents (each 23 stents of Gianturco, Silicone, and Gold stents) of 8-12 mm in diameter and 20 mm long were placed into normal abdominal aorta, inferior vena cava and lilac artery of nine adults dogs for 2 weeks to 11 months. It was more difficult to introduce Silicone stent into an introducing sheath than Gianturco or Gold stent due to the thickness of silicone rubber. Four Gianturco stents and three Silicone stents showed migration but Gold stent did not. Luminal narrowing or occlusion was noted in 3 Silicone stents. In 2 Gianturco stents, and in 1 Gold stent. Neointimal proliferation over the stent wires was more rapid and even in Gold stent than Silicone or Gianturco stent. Although further study is needed, Gold stent seems to be better than Gianturco or Silicone stent as an endovascular graft material

  5. IDENTIFICATION OF CFC AND HCFC SUBSTITUTES FOR BLOWING POLYURETHANE FOAM INSULATION PRODUCTS

    Science.gov (United States)

    The report gives results of a cooperative effort to identiry chlorofluorocarbons and hydrochlorofluorocarbon substitutes for blowing polyurethane foam insulation products. The substantial ongoing effort is identifying third-generation blowing agets for polyurethane foams to repla...

  6. SPECIFIC FEATURES OF OLIGOMERIC PRODUCT SOLIDIFICATION FROM POLYURETHANE WASTES AND THEIR PRACTICAL APPLICATION

    OpenAIRE

    V. Belyatsky; Yu. Kryvogus

    2012-01-01

    The paper considers a possibility to use secondary polyurethane obtained by  thermal depolymerization of wastes on the basis of cross-linked polyurethane (polyurethane adduct) and isocyanate. An effect of density dependence of the obtained polyurethane samples on nature and quantity of solvent has been revealed and it is significantly observed while using low-boiling solvents. The influence of adduct/solidification agent ratio on mechanical hardness of the obtained samples has been studied in...

  7. Tricuspid valved stent implantation: novel stent with a self-expandable super-absorbent polymer.

    Science.gov (United States)

    Iino, Kenji; Lozonschi, Lucian; Metzner, Anja; Marczynski-Bühlow, Martin; Renner, Jochen; Cremer, Jochen; Lutter, Georg

    2011-08-01

    Trans-catheter aortic and pulmonary valve replacement procedures can result in favorable outcomes in selected patients. The aim of this study was to investigate the functioning of a novel self-expanding valved stent with super-absorbent polymer (SAP) for minimally invasive replacement of the tricuspid valve. A newly designed nitinol stent with SAP was specially designed for the tricuspid annulus. This device was composed of right atrial anchoring elements, a left ventricular tubular stent, and a trileaflet bovine pericardial valve. The stent was coated with a waterproof material, and a pouch containing SAP for minimizing paravalvular leakage was placed beneath the atrial element. Seven pigs underwent minimally invasive off-pump tricuspid valved stent implantation. This was performed through a lower ministernotomy using a transventricular approach under transesophageal echocardiographic guidance. After 1 and 6h, a complete echocardiographic evaluation and hemodynamics (Swan-Ganz catheter) were performed. Six of seven pigs exhibited normal hemodynamics immediately after tricuspid valved stent implantation and maintained stability for the entire period of monitoring. In one pig, a part of the atrial stent elements was deployed into the right ventricle, leading to significant paravalvular leakage, and died very soon. All subsequent animals survived with good results in the observation period. Accurate positioning of the valved stent was documented in six of seven pigs. SAP expanded and filled the gap between the stent and the native annulus in all animals. Mild paravalvular leakage was found in two of the six animals. Nevertheless, the observed leakage decreased to trace levels 6h after implantation. In the additional four pigs, only trace tricuspid regurgitation was revealed. No right ventricular outflow tract obstruction was detected. Trans-apical off-pump tricuspid valved stent implantation is feasible in an acute experimental setting, and SAP may help to reduce

  8. Study on the application of big cup membranate stent on restenosis after stenting for carcinoma of esophago cardia

    International Nuclear Information System (INIS)

    Wang Xiuping; Yao Zhongqiang; Liu Jian; Zhang Yan

    2007-01-01

    Objective: To evaluate the clinical value of self-designed big cup membranate stent on restenosis after stenting for carcinoma of esophago-cardia. Methods: 12 cases of restenosis after stenting for carcinoma of esophago-cardia were involved in the study. Self-designed big cup membranate stent made by Nanjing Weichuang Company (the length of the cup was 3.5 cm)was placed into the constricted stent under guidance of fluoroscopy. Clinical effect, restenosis, and complications were observed during followed up. Results: All the 12 cases of big cup membranat stent placement went along smoothly without indigitation of the cup of the stent. Follow-up of 1.5-8 months showed that 2 cases developed severe restenosis on the big cup of the stem, resulting in third grade difficult deglutition. Among them, one occurred 1 month after stenting, caused by hyperplasia of large amount of granulation tissue; another occurred 6 months after stenting, caused by growth of tumor tissue. 3 cases developed mild to moderate restenosis, 2.3-7 months (mean: 4.6 months) after stenting, with result of first grade difficult deglutition. The remaining 7 cases (mean 5.6 months follow-up) did not have difficulty during deglutition. Conclusions: Application of big cup membranate stent on restenosis after stenting for carcinoma of esophago-cardia can effectively prevent the stent from moving downwards and thus lower down the rate of restenosis, and postpone the occurrence of restenosis. (authors)

  9. Very late bare-metal stent thrombosis, rare but stormy!

    LENUS (Irish Health Repository)

    Ali, Mohammed

    2011-08-01

    Recurrent in-stent thrombosis is rarely reported, with catastrophic clinical consequences of either acute coronary syndrome or death. We present a case of recurrent in-stent thrombosis with its outcome and a concise literature review.

  10. Hemodynamic comparison of stent configurations used for aortoiliac occlusive disease

    NARCIS (Netherlands)

    Groot Jebbink, Erik; Mathai, Varghese; Boersen, Johannes Thomas; Sun, Chao; Slump, Cornelis H.; Goverde, Peter C.J.M.; Versluis, Michel; Reijnen, Michel M.P.J.

    Background Endovascular treatment of aortoiliac occlusive disease entails the use of multiple stents to reconstruct the aortic bifurcation. Different configurations have been applied and geometric variations exist, as quantified in previous work. Other studies concluded that specific stent geometry

  11. Polyurethane Organosilicate Nanocomposites as Blood Compatible Coatings

    Directory of Open Access Journals (Sweden)

    Johnson H. Y. Chung

    2012-02-01

    Full Text Available Polymer clay nanocomposites (NCs show remarkable potential in the field of drug delivery due to their enhanced barrier properties. It is hypothesised that well dispersed clay particles within the polymer matrix create a tortuous pathway for diffusing therapeutic molecules, thereby resulting in more sustained release of the drug. As coatings for medical devices, these materials can simultaneously modulate drug release and improve the mechanical performance of an existing polymer system without introducing additional materials with new chemistries that can lead to regulatory concerns. In this study, polyurethane organosilicate nanocomposites (PUNCs coated onto stainless steel wires were evaluated for their feasibility as blood compatible coatings and as drug delivery systems. Heparin was selected as the model drug to examine the impact of silicate loading and modifier chain length in modulating release. Findings revealed that better dispersion was achieved from samples with lower clay loadings and longer alkyl chains. The blood compatibility of PUNCs as assessed by thrombin generation assays showed that the addition of silicate particles did not significantly decrease the thrombin generation lag time (TGT, p = 0.659 or the peak thrombin (p = 0.999 of polyurethane (PU. PUNC coatings fabricated in this research were not cytotoxic as examined by the cell growth inhibition assay and were uniformly intact, but had slightly higher growth inhibition compared to PU possibly due to the presence of organic modifiers (OM. The addition of heparin into PUNCs prolonged the TGT, indicating that heparin was still active after the coating process. Cumulative heparin release profiles showed that the majority of heparin released was from loosely attached residues on the surface of coils. The addition of heparin further prolonged the TGT as compared to coatings without added heparin, but a slight decrease in heparin activity was observed in the NCs

  12. Rheokinetics and effect of shear rate on the kinetics of linear polyurethane formation

    NARCIS (Netherlands)

    Navarchian, AH; Picchioni, F; Janssen, LPBM

    In this article, the rheokinetics of polyurethane formation and the influence of shear rate on its kinetics have been studied. Two different linear polyurethane systems with 0% and 100% hard segments are examined in a cone and plate rheometer. The isothermal increase of viscosity during polyurethane

  13. Polyurethanes for potential use in transparent armour investigated using DSC and DMA

    NARCIS (Netherlands)

    Ekeren, P.J. van; Carton, E.P.

    2011-01-01

    A material combination that may be applied as transparent armour is glass-clad polyurethane. These are comprised of a relatively thin glass strike face and a relatively thick (transparent) polyurethane backing layer. Three transparent polyurethane samples were investigated using differential

  14. 40 CFR 63.1294 - Standards for slabstock flexible polyurethane foam production-diisocyanate emissions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Standards for slabstock flexible polyurethane foam production-diisocyanate emissions. 63.1294 Section 63.1294 Protection of Environment... Flexible Polyurethane Foam Production § 63.1294 Standards for slabstock flexible polyurethane foam...

  15. 40 CFR 63.1293 - Standards for slabstock flexible polyurethane foam production.

    Science.gov (United States)

    2010-07-01

    ... polyurethane foam production. 63.1293 Section 63.1293 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... CATEGORIES National Emission Standards for Hazardous Air Pollutants for Flexible Polyurethane Foam Production § 63.1293 Standards for slabstock flexible polyurethane foam production. Each owner or operator of a...

  16. 40 CFR 63.1300 - Standards for molded flexible polyurethane foam production.

    Science.gov (United States)

    2010-07-01

    ... polyurethane foam production. 63.1300 Section 63.1300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... CATEGORIES National Emission Standards for Hazardous Air Pollutants for Flexible Polyurethane Foam Production § 63.1300 Standards for molded flexible polyurethane foam production. Each owner or operator of a new...

  17. Metallic Stents for Tracheobronchial Pathology Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Serrano, Carolina, E-mail: carolina.serrano@unizar.es [University of Zaragoza, Surgical Pathology Unit, Animal Pathology Department (Spain); Laborda, Alicia, E-mail: alaborda@unizar.es [University of Zaragoza, Minimally Invasive Techniques Research Group (GITMI) (Spain); Lozano, Juan M., E-mail: juamauloz@gmail.com [Marly Clinic, Radiology Department (Colombia); Caballero, Hugo, E-mail: hugocaballero2007@gmail.com [Marly Clinic, Pulmonology Department (Colombia); Sebastian, Antonio, E-mail: antonio.sebastian@ono.es [Lozano Blesa Clinical University Hospital, Pulmonology Department (Spain); Lopera, Jorge, E-mail: lopera@uthscsa.edu [Health Science Center, Interventional Radiology Deparment (United States); Gregorio, Miguel Angel de, E-mail: mgregori@unizar.es [University of Zaragoza, Minimally Invasive Techniques Research Group (GITMI) (Spain)

    2013-12-15

    Purpose: To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. Patients and Methods: One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniques at 48 h and at 1-, 3-, 6-, and 12-month intervals. Results: The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 {+-} 1.2 months in patients with malignant lesions and 76.2 {+-} 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Conclusion: Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results.

  18. Metallic stents for tracheobronchial pathology treatment.

    Science.gov (United States)

    Serrano, Carolina; Laborda, Alicia; Lozano, Juan M; Caballero, Hugo; Sebastián, Antonio; Lopera, Jorge; de Gregorio, Miguel Ángel

    2013-12-01

    To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniques at 48 h and at 1-, 3-, 6-, and 12-month intervals. The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 ± 1.2 months in patients with malignant lesions and 76.2 ± 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results.

  19. Transient Euler-Lagrange/DEM simulation of stent thrombosis

    Directory of Open Access Journals (Sweden)

    Stiehm Michael

    2016-09-01

    Full Text Available Stent implantation is the treatment of choice for cardiovascular diseases. By introduction of biodegradable thick strut stents investigations of thrombosis formation is one focus of research. This study deals with a transient Euler-Lagrange/DEM approach to simulate the flow field, platelet movement and clotting. The recirculation zones prolong particle residence time. As a result, the vicinity of stent struts shown a particularly higher risk for stent thrombosis.

  20. Development of asymmetric stent for treatment of eccentric plaque.

    Science.gov (United States)

    Syaifudin, Achmad; Takeda, Ryo; Sasaki, Katsuhiko

    2018-01-01

    The selection of stent and balloon type is decisive in the stenting process. In the treatment of an eccentric plaque obstruction, a symmetric expansion from stent dilatation generates nonuniform stress distribution, which may aggravate fibrous cap prone to rupture. This paper developed a new stent design to treat eccentric plaque using structural transient dynamic analysis in ANSYS. A non-symmetric structural geometry of stent is generated to obtain reasonable stress distribution safe for the arterial layer surrounding the stent. To derive the novel structural geometry, a Sinusoidal stent type is modified by varying struts length and width, adding bridges, and varying curvature width of struts. An end ring of stent struts was also modified to eliminate dogboning phenomenon and to reduce the Ectropion angle. Two balloon types were used to deploy the stent, an ordinary cylindrical and offset balloon. Positive modification results were used to construct the final non-symmetric stent design, called an Asymmetric stent. Analyses of the deformation characteristics, changes in surface roughness and induced stresses within intact arterial layer were subsequently examined. Interaction between the stent and vessel wall was implemented by means of changes in surface roughness and stress distribution analyses. The Palmaz and the Sinusoidal stent were used for a comparative study. This study indicated that the Asymmetric stent types reduced the central radial recoiling and the dogboning phenomenon. In terms of changes in surface roughness and induced stresses, the Asymmetric stent has a comparable effect with that of the Sinusoidal stent. In addition, it could enhance the distribution of surface roughening as expanded by an offset balloon.

  1. Unified Creep Plasticity Damage (UCPD) Model for Rigid Polyurethane Foams.

    Energy Technology Data Exchange (ETDEWEB)

    Neilsen, Michael K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lu, Wei-Yang [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Scherzinger, William M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hinnerichs, Terry D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lo, Chi S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-06-01

    Numerous experiments were performed to characterize the mechanical response of several different rigid polyurethane foams (FR3712, PMDI10, PMDI20, and TufFoam35) to large deformation. In these experiments, the effects of load path, loading rate, and temperature were investigated. Results from these experiments indicated that rigid polyurethane foams exhibit significant volumetric and deviatoric plasticity when they are compressed. Rigid polyurethane foams were also found to be very strain-rate and temperature dependent. These foams are also rather brittle and crack when loaded to small strains in tension or to larger strains in compression. Thus, a new Unified Creep Plasticity Damage (UCPD) model was developed and implemented into SIERRA with the name Foam Damage to describe the mechanical response of these foams to large deformation at a variety of temperatures and strain rates. This report includes a description of recent experiments and experimental findings. Next, development of a UCPD model for rigid, polyurethane foams is described. Selection of material parameters for a variety of rigid polyurethane foams is then discussed and finite element simulations with the new UCPD model are compared with experimental results to show behavior that can be captured with this model.

  2. Response of Polyurethane to Shock Waves: An Experimental Investigation

    Science.gov (United States)

    Jayaram, V.; Rao, Keshava Subba; Thanganayaki, N.; Kumara, H. K. T.; Reddy, K. P. J.

    Formation of polyurethane (PU) in vacuum environment and controlling density of polyurethane foams are the present day challenges. Polyurethane exists in numerous forms ranging from flexible to rigid and lightweight foams to tough, stiff elastomers [1]. PU can be used to produce lightweight foams for insulation or hard rubber used as wheels to transport heavy loads and it can be used in high pressure applications. The largest volumes of commercial PU elastomers are made from toluene diisocyanate (TDI) or diphenylmethane-4, 4'-diisocyanate (MDI) [2]. Linear polyurethanes can be processed into final products by any of the standard thermoplastic processes (injection molding, extrusion, thermoforming) as well as by low pressure cast processes in presence of catalysts. Tin, tetrabutyl titanate and zirconium chelates are few effective catalysts used to produce polyurethane for particular application [3]. Thermoset elastomers are formed due to irreversible cross-links, when polymers are chemically cured. Highly porous biodegradable PU was synthesized by thermally induced phase separation technique used in tissue engineering and also in bio-degradable based fluids [4]. Properties of PU like hardness, stress/strain modulus, tear strength etc, was determine using ASTM (American Society for Testing and Materials) standard methods. PU possesses extremely high mechanical properties, excellent abrasion, tear and extrusion resistance. It has outstanding low-temperature limit (-600C) and high temperature limit up to (1500C).

  3. Carboxylated Polyurethanes Containing Hyperbranched Polyester Soft Segments

    Directory of Open Access Journals (Sweden)

    Žigon, M.

    2006-09-01

    Full Text Available hyperbranched polyester soft segments (HB PU with functional carboxylic groups in order to enable the preparation of stable HB PU dispersions. Carboxylated hyperbranched polyurethanes were synthesized using a hyperbranched polyester based on 2,2-bis(methylolpropionic acid of the fourth pseudo-generation (Boltorn H40 and hexamethylene (HDI or isophorone diisocyanate (IPDI. The reactivity of hyperbranched polyester with HDI was lower than expected, possibly due to the presence of less reactive hydroxyl groups in the linear repeat units. A gel was formed at mole ratios rNCO/OH = 1:2 or 1:4. The synthesis of HB PU was performed with partly esterified hyperbranched polyester with lowered hydroxyl functionality. The carboxyl groups were incorporated in the HB PU backbone by reaction of residual hydroxyl groups with cis-1,2-cyclohexanedicarboxylic anhydride. HB PU aqueous dispersions were stable at least for two months, although their films were brittle. The tensile strength and Young's modulus of blends of linear and HB PU decreased with increasing content of HB PU whereas elongation at break remained nearly constant, which was explained in terms of looser chain packing due to more open tree-like hyperbranched structures.

  4. Melt electrospinning of biodegradable polyurethane scaffolds.

    Science.gov (United States)

    Karchin, Ari; Simonovsky, Felix I; Ratner, Buddy D; Sanders, Joan E

    2011-09-01

    Electrospinning from a melt, in contrast to from a solution, is an attractive tissue engineering scaffold manufacturing process as it allows for the formation of small diameter fibers while eliminating potentially cytotoxic solvents. Despite this, there is a dearth of literature on scaffold formation via melt electrospinning. This is likely due to the technical challenges related to the need for a well-controlled high-temperature setup and the difficulty in developing an appropriate polymer. In this paper, a biodegradable and thermally stable polyurethane (PU) is described specifically for use in melt electrospinning. Polymer formulations of aliphatic PUs based on (CH(2))(4)-content diisocyanates, polycaprolactone (PCL), 1,4-butanediamine and 1,4-butanediol (BD) were evaluated for utility in the melt electrospinning process. The final polymer formulation, a catalyst-purified PU based on 1,4-butane diisocyanate, PCL and BD in a 4/1/3M ratio with a weight-average molecular weight of about 40kDa, yielded a nontoxic polymer that could be readily electrospun from the melt. Scaffolds electrospun from this polymer contained point bonds between fibers and mechanical properties analogous to many in vivo soft tissues. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  5. Isothermal recovery rates in shape memory polyurethanes

    International Nuclear Information System (INIS)

    Azra, Charly; Plummer, Christopher J G; Månson, Jan-Anders E

    2011-01-01

    This work compares the time dependence of isothermal shape recovery in thermoset and thermoplastic shape memory polyurethanes (SMPUs) with comparable glass transition temperatures. In each case, tensile tests have been used to quantify the influence of various thermo-mechanical programming parameters (deformation temperature, recovery temperature, and stress and storage times following the deformation step) on strain recovery under zero load (free recovery) and stress recovery under fixed strain (constrained recovery). It is shown that the duration of the recovery event may be tuned over several decades of time with an appropriate choice of programming parameters, but that there is a trade-off between the rate of shape recovery and the recoverable stress level. The results are discussed in terms of the thermal characteristics of the SMPUs in the corresponding temperature range as characterized by modulated differential scanning calorimetry and dynamic mechanical analysis, with the emphasis on the role of the effective width of the glass transition temperature and the stability of the network that gives rise to the shape memory effect. (fast track communication)

  6. Nano-Aramid Fiber Reinforced Polyurethane Foam

    Science.gov (United States)

    Semmes, Edmund B.; Frances, Arnold

    2008-01-01

    Closed cell polyurethane and, particularly, polyisocyanurate foams are a large family of flexible and rigid products the result of a reactive two part process wherein a urethane based polyol is combined with a foaming or "blowing" agent to create a cellular solid at room temperature. The ratio of reactive components, the constituency of the base materials, temperature, humidity, molding, pouring, spraying and many other processing techniques vary greatly. However, there is no known process for incorporating reinforcing fibers small enough to be integrally dispersed within the cell walls resulting in superior final products. The key differentiating aspect from the current state of art resides in the many processing technologies to be fully developed from the novel concept of milled nano pulp aramid fibers and their enabling entanglement capability fully enclosed within the cell walls of these closed cell urethane foams. The authors present the results of research and development of reinforced foam processing, equipment development, strength characteristics and the evolution of its many applications.

  7. Polyurethane biocompatible silver bionanocomposites for biomedical applications

    Science.gov (United States)

    Filip, D.; Macocinschi, D.; Paslaru, E.; Munteanu, B. S.; Dumitriu, R. P.; Lungu, M.; Vasile, C.

    2014-11-01

    Bionanocomposite membranes based on polyurethane (PU), extracellular matrix (EM), and silver nanoparticles (AgNPs) were prepared by applying both solvent casting method and electrospinning/electrospraying method. PU-EM-Ag compositions were electrospun/electrosprayed onto PU membrane to realize improved biocompatible biomaterials. Surface morphological characteristics and wettability properties were investigated by SEM and AFM techniques and water contact angle measurements. Water contact angle depends on surface chemistry and the two methods employed for preparation of biomembranes as well as roughness of the membrane surfaces. Rheological study brings information on electrospinability of the polymer solutions/dispersions. Silver nanoparticles greatly influence the electrospinability of the polymer dispersions because of the increase in dynamic viscosity with the increasing silver content. Native PU and PU incorporated with low contents of AgNPs less than 0.3 % show high cell proliferation and good biocompatibility. The electrospun PU-EM-Ag nanobiocomposite membranes bring the advantage of using of low amounts of bioactive and biocidal components. The obtained silver nanobiocomposite membranes possess good bioactivity and non-cytotoxicity necessary for biomedical device applications. The obtained nanobiocomposite membranes are expected to find application for medical devices such as urinary catheters, wound dressings, etc.

  8. Shape memory of polyurethanes with silver nanoparticles

    International Nuclear Information System (INIS)

    Monteiro, Fernanda M.A.; Souza, Patterson P. de; Pereira, Iaci M.; Silva, Livio B.J. da; Orefice, Rodrigo L.

    2011-01-01

    Biodegradable polyurethane nano composites were synthesized in an aqueous environment and have their shape memory properties investigated. The matrix based in isopharane diisocyanate and poly(caprolactone diol) (Mn=1250, 2000 g.mol -1 ) was prepared by the prepolymer mixing process. The silver nanoparticles were produced by mixing AgNO 3 and tannic acid. The shape memory properties were measured using universal testing machine (DL3000, EMIC). The shape memory cycle consisted of the following steps: samples were deformed at room temperature; the mechanical constraints on the polymers were removed; samples were cooled down to 0 deg C and to retain the deformed shape; three processes were tested to recover the shape: (a) samples were heated up to 80 deg C in an oven, (b) immersed in pH 4.0 and (c) immersed in pH 7.0. To study the shape memory effect on the nanostructure, small angle X-ray scattering, wide angle X-ray scattering, infrared spectroscopy experiments were carried on. (author)

  9. Percutaneous transhepatic self-expanding metal stents for palliation ...

    African Journals Online (AJOL)

    Stent occlusion occurred in 4 patients (8%) within a week as result of stent migration (n=3) or presumed biliary sludge (n=1); 2 (4%) stents occluded between 7 days and 1 month. Four patients (8%) died during hospital admission due to pre-existing biliary sepsis (n=3) and pneumonia (n=1). Nine patients developed ...

  10. A scanning electron microscopic study of biliary stent materials

    NARCIS (Netherlands)

    van Berkel, A. M.; van Marle, J.; van Veen, H.; Groen, A. K.; Huibregtse, K.

    2000-01-01

    Clogging of biliary stents remains an important problem. In vitro studies have shown less sludge formation in Teflon stents. Recently, clinical studies with Teflon stents have produced contradictory results. The aim of this study was to investigate whether the surface properties of the

  11. Self-expanding metal stent placement for oesophageal cancer ...

    African Journals Online (AJOL)

    This article documents the technique and periprocedural experience. Patients and methods. All patients who had SEMS placement for ... Repeat stenting was for stent migration (n=15), tumour overgrowth (n=26) and a blocked stent and a stricture (n=1 each). Complications were recorded in six cases (1.3%): iatrogenic TOF ...

  12. Mechanical Behavior of Fully Expanded Commercially Available Endovascular Coronary Stents

    OpenAIRE

    Tambaca, Josip; Canic, Suncica; Kosor, Mate; Fish, R. David; Paniagua, David

    2011-01-01

    The mechanical behavior of endovascular coronary stents influences their therapeutic efficacy. Through computational studies, researchers can analyze device performance and improve designs. We developed a 1-dimensional finite element method, net-based algorithm and used it to analyze the effects of radial loading and bending in commercially available stents. Our computational study included designs modeled on the Express, Cypher, Xience, and Palmaz stents.

  13. Modelling and simulating in-stent restenosis with complex automata

    NARCIS (Netherlands)

    Hoekstra, A.G.; Lawford, P.; Hose, R.

    2010-01-01

    In-stent restenosis, the maladaptive response of a blood vessel to injury caused by the deployment of a stent, is a multiscale system involving a large number of biological and physical processes. We describe a Complex Automata Model for in-stent restenosis, coupling bulk flow, drug diffusion, and

  14. Pathological aspects of bioresorbable stent implantation.

    Science.gov (United States)

    Sanchez, Oscar D; Yahagi, Kazuyuki; Byrne, Robert A; Mori, Hiroyoshi; Zarpak, Roya; Wittchow, Eric; Foin, Nicolas; Virmani, Renu; Joner, Michael

    2015-01-01

    The treatment of obstructive coronary artery disease has been revolutionised by the advent of drug-eluting stent therapy. However, concerns remain about complications late after stent implantation including late stent thrombosis, hypersensitivity reactions and neoatherosclerosis. In this respect, the introduction of fully bioresorbable stents (BRS)--which resorb over time and leave the arterial wall free of any metal constraints--represents a potentially important disruptive technology. However, although the concept is intuitively attractive, a thorough understanding of the histopathological changes seen after BRS implantation and an appreciation of comparative changes versus existing metal stent technologies are vital to guide BRS clinical usage. In this respect, translational investigation of polymer chemistry, biomedical engineering, as well as in vitro and in vivo testing in animal models is an important undertaking. This article will review the pathological aspects of BRS implantation with a focus on acute and chronic vascular reactions derived from preclinical animal studies, including insights from in vivo imaging. Finally, potential future directions of this novel therapeutic approach will be discussed.

  15. Clinical and angiographic features of small vessel stenting in the drug-eluting stent era.

    Science.gov (United States)

    Jabara, Refat; Gradman, Marc; Chen, Jack P; King, Spencer B; Gadesam, Radhika; Chronos, Nicolas A F

    2009-06-01

    This study was designed to investigate the clinical and angiographic features and procedural outcomes of small-vessel stenting in a real-world experience during the transition era between drug-eluting stents (DES) and bare-metal stents (BMS). Using one of the largest single-institutional cohorts, this study evaluated all patients who underwent percutaneous coronary intervention (PCI) from 2002 through 2005. Analysis was restricted to patients receiving a single stent or undergoing balloon-only angioplasty in a single anatomic site. Small-vessel stents (SVS) were defined as 2.00 to 2.75 mm and large-vessel stents (LVS) as 3.00 to 4.00 mm in diameter. A total of 19,580 stents were placed in 10,396 patients. Of 6208 patients fulfilling inclusion criteria, 1630 (26.3%) received SVS, and 4578 (73.7%) received LVS. The SVS group had more female (35.5% vs 26.3%, P LVS group. Compared with LVS, SVS lesions were shorter (14.5 +/- 5.8 mm vs 15.7 +/- 6.4 mm, P performance characteristics, our study, one of the largest single-center experiences in small-vessel PCI, suggests that the availability of DES substantially increased the use of SVS, as opposed to balloon-only angioplasty, in this anatomically challenging setting. 2009 Wiley Periodicals, Inc.

  16. Direct transfer of graphene films for polyurethane substrate

    International Nuclear Information System (INIS)

    Vilani, C.; Romani, E.C.; Larrudé, D.G.; Barbosa, Gelza M.; Freire, F.L.

    2015-01-01

    Highlights: • Graphene was prepared by CVD using copper foils as substrates. • Monolayer, bilayer and multilayer graphene were transferred to PU. • Samples were characterized by Raman and optical spectroscopies. • PU/monolayer graphene has transmittance around 80% in visible range. - Abstract: We have proposed the direct transfer of large-area graphene films grown by chemical vapor deposition to polymeric substrate by evaporating of solvents of polyurethane/tetrahydrofurane solution. The graphene films on polyurethane substrates were characterized by Raman spectroscopy, optical and atomic force microscopies and UV–vis spectroscopy measurements. The Raman spectra revealed that it is possible to transfer in a controlled manner monolayer, bilayer and multilayer graphene films over polyurethane substrate.

  17. Direct transfer of graphene films for polyurethane substrate

    Energy Technology Data Exchange (ETDEWEB)

    Vilani, C.; Romani, E.C.; Larrudé, D.G. [Departamento de Física, Pontifícia Universidade Católica do Rio de Janeiro, 22451-900 Rio de Janeiro, RJ (Brazil); Barbosa, Gelza M. [Diretoria de Sistemas de Armas da Marinha, Marinha do Brasil, 20010-00 Rio de Janeiro, RJ (Brazil); Freire, F.L., E-mail: lazaro@vdg.fis.puc-rio.br [Departamento de Física, Pontifícia Universidade Católica do Rio de Janeiro, 22451-900 Rio de Janeiro, RJ (Brazil); Centro Brasileiro de Pesquisas Físicas, 22290-180 Rio de Janeiro, RJ (Brazil)

    2015-11-30

    Highlights: • Graphene was prepared by CVD using copper foils as substrates. • Monolayer, bilayer and multilayer graphene were transferred to PU. • Samples were characterized by Raman and optical spectroscopies. • PU/monolayer graphene has transmittance around 80% in visible range. - Abstract: We have proposed the direct transfer of large-area graphene films grown by chemical vapor deposition to polymeric substrate by evaporating of solvents of polyurethane/tetrahydrofurane solution. The graphene films on polyurethane substrates were characterized by Raman spectroscopy, optical and atomic force microscopies and UV–vis spectroscopy measurements. The Raman spectra revealed that it is possible to transfer in a controlled manner monolayer, bilayer and multilayer graphene films over polyurethane substrate.

  18. Antimicrobial polyurethane thermosets based on undecylenic acid: synthesis and evaluation.

    Science.gov (United States)

    Lluch, Cristina; Esteve-Zarzoso, Braulio; Bordons, Albert; Lligadas, Gerard; Ronda, Juan C; Galià, Marina; Cádiz, Virginia

    2014-08-01

    In the present study, plant oil-derived surface-modifiable polyurethane thermosets are presented. Polyol synthesis is carried out taking advantage of thiol-yne photopolymerization of undecylenic acid derivatives containing methyl ester or hydroxyl moieties. The prepared methyl ester-containing polyurethanes allow surface modification treatment to enhance their hydrophilicity and impart antimicrobial activity through the following two steps: i) grafting poly(propylene glycol) monoamine (Jeffamine M-600) via aminolysis and ii) Jeffamine M-600 layer complexation with iodine. The antimicrobial activity of the iodine-containing polyurethanes is demonstrated by its capacity to inhibit the growth of Staphylococcus aureus, and Candida albicans in agar media. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Alginate based polyurethanes: A review of recent advances and perspective.

    Science.gov (United States)

    Zia, Khalid Mahmood; Zia, Fatima; Zuber, Mohammad; Rehman, Saima; Ahmad, Mirza Nadeem

    2015-08-01

    The trend of using biopolymers in combination with synthetic polymers was increasing rapidly from last two or three decades. Polysaccharide based biopolymers especially starch, cellulose, chitin, chitosan, alginate, etc. found extensive applications for different industrial uses, as they are biocompatible, biodegradable, bio-renewable resources and chiefly environment friendly. Segment block copolymer character of polyurethanes that endows them a broad range of versatility in terms of tailoring their properties was employed in conjunction with various natural polymers resulted in modified biomaterials. Alginate is biodegradable, biocompatible, bioactive, less toxic and low cost anionic polysaccharide, as a part of structural component of bacteria and brown algae (sea weed) is quite abundant in nature. It is used in combination with polyurethanes to form elastomers, nano-composites, hydrogels, etc. that especially revolutionized the food and biomedical industries. The review summarized the development in alginate based polyurethanes with their potential applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Thermal Properties of Anionic Polyurethane Composition for Leather Finishing

    Directory of Open Access Journals (Sweden)

    Olga KOVTUNENKO

    2016-09-01

    Full Text Available Thermal properties of anionic polyurethane composition mixed with collagen product and hydrophilic sodium form of montmorillonite for use in the finishing of leather were studied by thermogravimetric method. The thermal indices of processes of thermal and thermo-oxidative destruction depending on the polyurethane composition were determined. The influence of anionic polyurethane composition on thermal behavior of chromium tanned gelatin films that imitate the leather were studied. APU composition with natural compounds increases their thermal stability both in air and in nitrogen atmosphere due to the formation of additional bonds between active groups of APU, protein and chrome tanning agent as the result of chemical reactions between organic and inorganic parts with the new structure formation.DOI: http://dx.doi.org/10.5755/j01.ms.22.3.10043

  1. The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

    Science.gov (United States)

    Campbell, Paul T; Kruse, Kevin R; Kroll, Christopher R; Patterson, Janet Y; Esposito, Michele J

    2015-09-01

    Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System. Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively. Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate. Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Anchoring barbs and balloon expandable stents: what is the risk of perforation and failed stent deployment?

    Science.gov (United States)

    Bown, M J; Harrison, G J; How, T V; Brennan, J A; Fisher, R K; Vallabhaneni, S R; McWilliams, R G

    2012-09-01

    Balloon expandable stents may on occasion be deployed in close proximity to the anchoring barbs of endovascular grafts. The aim of this study was to determine the risk and effect of balloon perforation by anchoring barbs and to assess whether these risks are different if the balloon is protected by a covered stent mounted upon it. A bench-top model was developed to mimic the penetration of anchoring barbs into the lumen of medium sized blood vessels. The model allowed variation of angle and depth of vessel penetration. Both bare balloons and those with covered stents mounted upon them were tested in the model to determine whether there was a risk of perforation and which factors increased or decreased this risk. All combinations of barb angle and depth caused balloon perforation but this was most marked when the barb was placed perpendicular to the long axis of the balloon. When the deployment of covered stents was attempted balloon perforation occurred in some cases but full stent deployment was achieved in all cases where the perforation was in the portion of the balloon covered by the stent. The only situation in which stent deployment failed was where the barb was intentionally placed in the uncovered portion of the balloon. This resulted in only partial deployment of the stent. Balloon rupture is a distinct possibility when deploying balloon-expandable stents in close proximity to anchoring barbs. Care should be taken in this circumstance to ensure that the barb is well away from the uncovered portion of the balloon. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Clinical outcomes and prognosis of patients with stent fracture after successful drug-eluting stent implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Soo [Cadiovascular center, Chonnam National University Hospital, Gwangju (Korea, Republic of); Han, Jae Bok; Jang, Seong Joo [Dept. of Radiology, Dongshin University, Naju (Korea, Republic of)

    2014-06-15

    Many studies have suggested that in the era of Drug Eluting Stents (DES) are one of the causes of In-Stent Restenosis (ISR) of Stent Fracture (SF). The present study sought to evaluate clinical characteristics of patients with stent fracture after successful DES implantation. The 4,701 patients were selected for analysis who underwent a follow-up coronary angiography irrespective of ischemic symptoms. The overall incidence of SF was 32 patients(male:female=19:13, Av. age 62.44±9.8 year, 0.68%). Fractures of Sirolimus-Eluting Stents (SES), Paclitaxel-Eluting Stents (PES), Biolimus A9-Eluting Stents (BES), Everolimus-Eluting Etents (EES), Endothelial Progenitor Cell Capture Stent (EPC) and Zotarolimus-Eluting Stents (ZES) are accounted for 19 (59.4%), 9 (28.1%), 2 (6.3%), 1 (3.1%), 1 (3.1%) and 0 (0%) respectively. SF developed in the left Anterior Dscending (LAD) artery in 16 patients (50%) and in complex(type B2, C) lesions in 25 patients (69.4%). Ten patients were treated with heterogenous DES, the rest being treated with either homogenous DES (3 patients), plain old balloon angioplasty (3 patients), or conservative medical treatment (17 patients). None of the patients with SF suffered from cardiac death during a follow-up period of 32.9±12.4 months. The overall rate of DES fracture over up to 3.7 years of follow-up was 0.68% with higher incidence in SES than in PES. SF frequently occurred in the LAD artery and in complex lesions. Of the patients with SF, coronary intervention was performed only when the binary restenosis lesion was significant. During the follow-up, patients with SF have continued on combination antiplatelet therapy. There is a very low rate of major adverse cardiac events(post-detection of SF), especially cardiac death associated with SF.

  4. Stent placement for tracheal stenosis in patients with esophageal cancer

    International Nuclear Information System (INIS)

    Takagi, Keigo; Hata, Yoshinobu; Sasamoto, Shuichi; Takahashi, Shoji; Sato, Fumitomo; Tamaki, Kazuyoshi; Goto, Hidenori; Yuasa, Rena

    2011-01-01

    Tracheal invasion including tracheal bifurcation due to esophageal cancer can sometimes cause serious complications of the airway, but such cases sometimes improve quickly following chemoradiation treatment. The absolute indications for stent replacement in the airway for this disorder and the optimal choice of stent are herein discussed. Between 1992 and 2010, 28 patients with airway stenosis, including 7 patients with esophago-tracheal fistula, were treated by placement of various stents; namely, 12 patients received Dumon stents, 3 patients had Dynamic stents, 10 patients were given Ultraflex stents, while 3 other patients were treated without the use of stents. Severe dyspnea in the supine position was observed, which mainly originated from invasion to the membranous portion of the trachea. Airway patency was maintained after stent replacement, although the median survival time of such cases was only 4 months. Three patients with severe dyspnea who could lie in a supine position recovered after undergoing chemoradiation treatment without stent replacement. No cases of stent removal were observed after chemoradiation treatment. Chemoradiation treatment for esophageal cancer was found to be effective for the management of airway disturbances, and thus the absolute indications for stent replacement are restricted to patients who cannot lie in a supine position due to severe impairment of ventilation during radiation therapy, as well as patients presenting with tracheobroncho-esophageal fistula. Concerning stent selection, a metal stent should be the first choice for tracheal stenosis due to its ease of insertion, because there is no substantial difference between silicone and metal stents regarding the treatment of tracheal stenosis. However, it is important to note that a silicone Y stent is useful for the treatment of tracheal bifurcation. (author)

  5. Synthesis and characterization of isophorone diisocyanate based polyurethanes

    Science.gov (United States)

    Mirčeva, A.; Malavašič, T.; Osredkar, U.

    1990-03-01

    Polyurethane ionomers based on polycaprolactone glycol or polyoxytetramethylene glycol with isophorone diisocyanate and chain extenders 1,4-butanediol, 2,2'(dihydroxymethyl) propionic acid and in some cases water, were synthesized in solution. Stable aqueous dispersions from the ionomers were obtained when the concentration of ionic groups was at least 30 mmol per 100 g of polyurethane. Higher concentration of hard segments in the structure produced elastic and transparent films. Hard-soft segment interactions in a series of model compounds were estimated by Fourier transform infrared spectroscopy. Thermal properties of the films were determined by differential scanning calorimetry and by FTIR as well.

  6. Fabrication and characterization of cellulose nanocrystal based transparent electroactive polyurethane

    Science.gov (United States)

    Ko, Hyun-U.; Kim, Hyun Chan; Kim, Jung Woong; Zhai, Lindong; Jayaramudu, Tippabattini; Kim, Jaehwan

    2017-08-01

    This paper reports cellulose nanocrystal (CNC) based transparent and electroactive polyurethane (CPPU), suitable for actively tunable optical lens. CNC is used for high dielectric filler to improve electromechanical behavior of CPPU. For high transparency and homogeneous distribution of CNC in polyurethane, CNC-poly[di(ethylene glycol) adipate] is used to play a role of polyol and isocyanate salt. The fabricated CPPU exhibits high transparency (>90%) and 10% of electromechanical strain under 3 V μm-1 electric field. Mechanical, dielectric properties as well as physical and chemical characteristics are investigated to prove the electromechanical behavior of CPPU.

  7. Stenting of the SFA - indications, techniques,

    International Nuclear Information System (INIS)

    Rieger, J.; Treitl, M.; Reiser, M.; Ruppert, V.

    2006-01-01

    Aggressive risk factor modification, change of eating habits, exercise programs, and forceful antiplatelet therapy are the most important tools for the treatment of PAOD in symptomatic patients suffering from intermittent claudication. There are however no guidelines for revascularization at this stage. Endovascular treatment has been increasingly utilized over the last decade and increasingly displaced vascular surgery. Amongst numerous endovascular techniques beside PTA, stents meanwhile play the most important role due to constant technical progress. Results regarding the rate of restenosis or patency rates still remain worse compared to other vascular beds. This paper gives a review over recent results, currently available stent techniques, and possible indications for the endovascular therapy of an artery, which has turned out to be the biggest ordeal for material and construction of stents. (orig.) [de

  8. Auxetic Polyurethane Foam (Fabrication, Properties and Applications)

    International Nuclear Information System (INIS)

    Yousif, H.I.Y.

    2012-01-01

    Modern technology requires new materials of special properties. For the last two decades there has been a great interest in a class of materials known as auxetic materials. An auxetic material is a material that has a negative Poisson's ratio which means that this material expands laterally when they subjected to a tensile force unlike most of the other traditional materials. This material has superior properties over the traditional material such as high shear modulus and high impact resistance, which makes this material a good candidate for many engineering applications. In the present research work, auxetic flexible polyurethane polymeric foams having different densities were fabricated from conventional flexible polyurethane polymeric foam at different compression ratios. The microstructure of conventional and processed foams was examined by optical microscope to compare between the two structures. The microstructure of processed foam was compared with the one presented in the literature and it has shown the auxetic structure configuration. This is the first time to produce auxetic foam in Egypt. Conventional and auxetic foam samples having cylindrical and square cross-sections were produced from foams having different densities (25 kg/m 3 and 30 kg/m 3 ). The compression ratios used to produce the auxetic samples are (5.56, 6.94 and 9.26). Four mechanical tests were carried out to get the mechanical properties for both conventional and auxetic foams. Two quasi-static mechanical tests t ension and compression a nd two dynamic mechanical tests H ysteresis and resilience w ere carried out to compare between the conventional and auxetic foams. The quasi-static tensile test was carried out at speed was adjusted to be position control rate of 0.2 mm/s. The compression and hysteresis tests were carried out at strain control rate of 0.3 S -1 . The data recorded from the machine were stress and strain. The modulus of elasticity and Poisson's ratio of the test

  9. Prospective Evaluation of Two iStent® Trabecular Stents, One iStent Supra® Suprachoroidal Stent, and Postoperative Prostaglandin in Refractory Glaucoma: 4-year Outcomes.

    Science.gov (United States)

    Myers, Jonathan S; Masood, Imran; Hornbeak, Dana M; Belda, Jose I; Auffarth, Gerd; Jünemann, Anselm; Giamporcaro, Jane Ellen; Martinez-de-la-Casa, Jose M; Ahmed, Iqbal Ike K; Voskanyan, Lilit; Katz, L Jay

    2018-03-01

    This study evaluates long-term outcomes of two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin in eyes with refractory open angle glaucoma (OAG). Prospective ongoing 5-year study of 80 eligible subjects (70 with 4-year follow-up) with OAG and IOP ≥ 18 mmHg after prior trabeculectomy and while taking 1-3 glaucoma medications. Subjects received two iStent ® trabecular micro-bypass stents, one iStent Supra ® suprachoroidal stent, and postoperative travoprost. Postoperative IOP was measured with medication and annually following medication washouts. Performance was measured by the proportion of eyes with ≥ 20% IOP reduction on one medication (the protocol-specified prostaglandin) versus preoperative medicated IOP (primary outcome); and the proportion of eyes with postoperative IOP ≤ 15 and ≤ 18 mmHg on one medication (secondary outcome). Additional clinical and safety data included medications, visual field, pachymetry, gonioscopy, adverse events, visual acuity, and slit-lamp and fundus examinations. Preoperatively, mean medicated IOP was 22.0 ± 3.1 mmHg on 1.2 ± 0.4 medications, and mean unmedicated IOP was 26.4 ± 2.4 mmHg. Postoperatively, among eyes without later cataract surgery, mean medicated IOP at all visits through 48 months was ≤ 13.7 mmHg (≥ 37% reduction), and annual unmedicated IOP was ≤ 18.4 mmHg (reductions of ≥ 30% vs. preoperative unmedicated IOP and ≥ 16% vs. preoperative medicated IOP). At all postoperative visits among eyes without additional surgery or medication, ≥ 91% of eyes had ≥ 20% IOP reduction on one medication versus preoperative medicated IOP. At month 48, 97 and 98% of eyes achieved IOP ≤ 15 and ≤ 18 mmHg, respectively, on one medication. Six eyes required additional medication, no eyes required additional glaucoma surgery, and safety measurements were favorable throughout follow-up. IOP control was achieved safely with two

  10. Drug-eluting stents in renal artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M. [Marienhospital Stuttgart, Department of Radiology, Stuttgart (Germany); Pattynama, P.M.T. [Erasmus MC-University Medical Center Rotterdam, Rotterdam (Netherlands); Talen, A. [genae associates nv, Antwerp (Belgium); Sapoval, M. [Hopital Europeen Georges Pompidou, Service de Radiologie Cardio-Vasculaire, Paris (France); Inserm U 780 epidemiologie Cardio Vasculaire, Paris (France)

    2008-04-15

    Because of higher acute and long-term success rates compared with balloon angioplasty alone, percutaneous stent implantation has become an accepted therapy for the treatment of atherosclerotic renal artery stenosis. Restenosis rates after successful renal stent placement vary from 6 up to 40%, depending on the definition of restenosis, the diameter of the treated vessel segment and comorbidities. The safety and efficacy of drug-eluting stents for the treatment of renal-artery stenosis is poorly defined. The recently published GREAT study is the only prospective study, comparing bare-metal and sirolimus-coated low profile stent systems in renal artery stenosis, showing a relative risk reduction of angiographic binary in-stent restenosis by 50%. This is an opinion paper on indications, current treatment options and restenosis rates following renal artery stenting and the potential use of drug-eluting stents for this indication. (orig.)

  11. Carotid stent infection: a rare but potentially fatal complication of carotid artery stenting.

    Science.gov (United States)

    Son, Seungnam; Choi, Nack-Cheon; Choi, Dae Seob; Cho, Oh Hyun

    2015-04-01

    Infections involving endovascular devices are rare and, to our knowledge, only three cases of infection with an inserted carotid stent have ever been reported. A 68-year-old man underwent carotid artery stenting (CAS) of the left proximal internal carotid artery. Two days after CAS the patient developed a high fever and investigation showed that the inserted carotid stent was infected. The infection could not be controlled despite adequate antibiotic therapy. Eventually a rupture of the carotid artery occurred and the patient underwent emergency resection of the left carotid bifurcation in addition to stent removal and reconstruction with a saphenous vein interposition graft. The patient recovered fully without any neurological sequelae. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Drug-eluting stents versus bare-metal stents for acute coronary syndrome

    DEFF Research Database (Denmark)

    Feinberg, Joshua; Nielsen, Emil Eik; Greenhalgh, Janette

    2017-01-01

    BACKGROUND: Approximately 3.7 million people died from acute coronary syndrome worldwide in 2012. Acute coronary syndrome, also known as myocardial infarction or unstable angina pectoris, is caused by a sudden blockage of the blood supplied to the heart muscle. Percutaneous coronary intervention...... CRITERIA: Randomised clinical trials assessing the effects of drug-eluting stents versus bare-metal stents for acute coronary syndrome. We included trials irrespective of publication type, status, date, or language. DATA COLLECTION AND ANALYSIS: We followed our published protocol and the methodological......-eluting stents group compared with 6.63% in the bare-metal stents group based on the RR of 0.96 (95% CI 0.83 to 1.11, 10,939 participants, 19 trials/20 comparisons, very low-quality evidence). The results of Trial Sequential Analysis showed that we did not have sufficient information to confirm or reject our...

  13. Preclinical evaluation of new indomethacin-eluting biodegradable urethral stent.

    Science.gov (United States)

    Kotsar, Andres; Nieminen, Riina; Isotalo, Taina; Mikkonen, Joonas; Uurto, Ilkka; Kellomäki, Minna; Talja, Martti; Moilanen, Eeva; Tammela, Teuvo L J

    2012-04-01

    To evaluate the effect of an indomethacin-eluting biodegradable urethral stent on the production of inflammatory cytokines in vitro and the degradation and biocompatibility of the new stent in vivo. The effects of an indomethacin and indomethacin-eluting biodegradable stent on monocyte chemoattractant protein (MCP)-1, RANTES (regulated on activation, normal T-cell expressed and secreted), and transforming growth factor-ß were measured in THP-1 cells by enzyme-linked immunosorbent assay. Stents (copolymer of L-lactide and glycolide acid) that were coated with 50L/50D polylactic acid and two different concentrations of indomethacin were inserted into the rabbit urethra. Stents without the drug were used as controls. Scanning electron microscopy (SEM) was used to assess the degradation of the stents. Biocompatibility was evaluated using histologic analyses of the urethral specimen. The measurements were performed at 3 weeks and 3 months. Indomethacin and indomethacin-releasing stent material inhibited MCP-1 and RANTES production in activated THP-1 macrophages. SEM analysis revealed that indomethacin coating had no effect on the degradation process of the stents and less epithelial polyposis had developed in the indomethacin stent group. In histologic analyses at 3 weeks, indomethacin-eluting stents caused more calcification but no significant differences in other tissue reactions. At 3 months, the indomethacin-eluting stents caused less inflammatory reaction and calcification compared with the control stents. Indomethacin-eluting property can be safely added to biodegradable stents without major influence on the degradation time. The development of epithelial polyposis in the urethra can be potentially reduced by the new indomethacin-eluting urethral stents.

  14. Flow Characteristics Near to Stent Strut Configurations on Femoropopliteal Artery

    Science.gov (United States)

    Paisal, Muhammad Sufyan Amir; Fadhil Syed Adnan, Syed; Taib, Ishkrizat; Ismail, Al Emran; Kamil Abdullah, Mohammad; Nordin, Normayati; Seri, Suzairin Md; Darlis, Nofrizalidris

    2017-08-01

    Femoropopiteal artery stenting is a common procedure suggested by medical expert especially for patient who is diagnosed with severe stenosis. Many researchers reported that the growth of stenosis is significantly related to the geometry of stent strut configuration. The different shapes of stent geometry are presenting the different flow pattern and re-circulation in stented femoropopliteal artery. The blood flow characteristics near to the stent geometry are predicted for the possibility of thrombosis and atherosclerosis to be formed as well as increase the growth of stenosis. Thus, this study aims to determine the flow characteristic near to stent strut configuration based on different hemodynamic parameters. Three dimensional models of stent and simplified femoropopliteal artery are modelled using computer aided design (CAD) software. Three different models of stent shapes; hexagon, circle and rectangle are simulated using computational fluid dynamic (CFD) method. Then, parametric study is implemented to predict the performance of stent due to hemodynamic differences. The hemodynamic parameters considered are pressure, velocity, low wall shear stress (WSSlow) and wall shear stress (WSS). From the observation, flow re-circulation has been formed for all simulated stent models which the proximal region shown the severe vortices. However, rectangular shape of stent strut (Type P3) shows the lowest WSSlow and the highest WSS between the range of 4 dyne/cm2 and 70 dyne/cm2. Stent Type P3 also shows the best hemodynamic stent performance as compare to others. In conclusion, Type P3 has a favourable result in hemodynamic stent performance that predicted less probability of thrombosis and atherosclerosis to be formed as well as reduces the growth of restenosis.

  15. Computational simulation of platelet interactions in the initiation of stent thrombosis due to stent malapposition

    Science.gov (United States)

    Chesnutt, Jennifer K. W.; Han, Hai-Chao

    2016-02-01

    Coronary stenting is one of the most commonly used approaches to open coronary arteries blocked due to atherosclerosis. Stent malapposition can induce thrombosis but the microscopic process is poorly understood. The objective of this study was to determine the platelet-level process by which different extents of stent malapposition affect the initiation of stent thrombosis. We utilized a discrete element model to computationally simulate the transport, adhesion, and activation of thousands of individual platelets and red blood cells during thrombus initiation in stented coronary arteries. Simulated arteries contained a malapposed stent with a specified gap distance (0, 10, 25, 50, or 200 μm) between the struts and endothelium. Platelet-level details of thrombus formation near the proximal-most strut were measured during the simulations. The relationship between gap distance and amount of thrombus in the artery varied depending on different conditions (e.g., amount of dysfunctional endothelium, shear-induced activation of platelets, and thrombogenicity of the strut). Without considering shear-induced platelet activation, the largest gap distance (200 μm) produced no recirculation and less thrombus than the smallest two gap distances (0 and 10 μm) that created recirculation downstream of the strut. However, with the occurrence of shear-induced platelet activation, the largest gap distance produced more thrombus than the two smallest gap distances, but less thrombus than an intermediate gap distance (25 μm). A large gap distance was not necessarily the most thrombogenic, in contrast to implications of some computational fluid dynamics studies. The severity of stent malapposition affected initial stent thrombosis differently depending on various factors related to fluid recirculation, platelet trajectories, shear stress, and endothelial condition.

  16. Mechanical Properties of Metallic Stents: How Do These Properties Influence the Choice of Stent for Specific Lesions?

    International Nuclear Information System (INIS)

    Dyet, John F.; Watts, William G.; Ettles, Duncan F.; Nicholson, Anthony A.

    2000-01-01

    Purpose: To assess selected balloon-expandable and self-expanding stents for radial force, flexibility, radio-opacity, and trackability, and to relate these physical characteristics to potential indications for placement.Methods: Force-strain curves were plotted for each stent and the force required to produce 50% luminal narrowing was recorded. The ability of the stent to show elastic recoil following deformation was also noted. Flexibility was measured by bending the stents against a force transducer and recording the force required per degree of flexion. Radio-opacity was measured by comparing each stent against a standard aluminum step wedge. Trackability was measured by testing the ability of the stent on its delivery system to track over angles of 90 deg. and 60 deg. Results: The balloon-expandable stents showed greater radial strength and radio-opacity but, apart from the AVE Iliac Bridge stent, showed poorer flexibility and trackability. The self-expanding stents showed less radial force but were able to re-expand following deformity. They were generally more flexible and had better trackability but lower radio-opacity.Conclusion: There is no stent which exhibits all the ideal properties required and therefore the interventionist will need to keep a range of stents available if all lesions are to be addressed

  17. Metallic stents provide better QOL than plastic stents in patients with stricture of unresectable advanced esophageal cancer

    International Nuclear Information System (INIS)

    Ohta, Kazuki; Nagahara, Akihito; Iijima, Katsuyori

    2006-01-01

    The aim of this study was to elucidate the utility and safety of treatment with esophageal stents (plastic and metallic stents) for unresectable advanced esophageal cancer. Between 1992 and 2002, 14 cases of unresectable advanced esophageal cancer were treated with esophageal stents (the plastic stent group, 7 cases; and the metallic stent group, 7 cases). Of these, 10 cases had a history of chemotherapy and or radiotherapy. An improvement in oral intake and performance status (PS), survival time, periods at home, and adverse events were compared between the two groups. After stenting, oral intake and PS were significantly improved in the metallic stent group. Follow-up at home was possible in 71.4%. There was no significant difference in survival or duration of time at home between the two groups. All adverse events were controllable and there was no difference between the two groups. Stenting not only improved oral intake and PS but also allowed a stay at home, resulting in a marked improvement in patients' quality of life (QOL). Stenting was performed safely even in cases with a history of radiotherapy. There was no difference in survival, ratios of staying at home, and safety between the two groups, but QOL was significantly improved in the metallic stent group. These outcomes indicate that placement of metallic stents should be actively considered to treat stricture due to advanced esophageal cancer. (author)

  18. [Vertebral-subclavian bifurcation treatment. "The wedding ring technique" for a vertebral in-stent restenosis associated with stent fracture].

    Science.gov (United States)

    Damas-De Los Santos, Félix; Colombo, Federico; Zuffi, Andrea; Cremonesi, Alberto

    2015-01-01

    This report describes a solution for a restenosis and for the fracture of a stent in the vertebral artery in a patient suffering from vertebrobasilar symptoms. Angiography demonstrates restenosis of a vertebral stent as well as its fracture and migration into the subclavian artery. This complication was managed percutaneously by passing a guide wire through the fractured stent. Pre-dilatation and kissing balloon techniques were applied in both the vertebral and subclavian arteries to modify the stent's dimensions and shape it into the form of a "ring." Postprocedural angiography demonstrated an excellent final result with the assistance of StentBoost visualization. Control angiography at six months also utilized StentBoost imaging and confirmed the patency of the bifurcation and that the stent was not displaced.

  19. Clinical outcomes of re-stenting in patients with stent malfunction in malignant gastric outlet obstruction.

    Science.gov (United States)

    Jin, Eun Hyo; Kim, Sang Gyun; Seo, Ji Yeon; Im, Jong Pil; Kim, Joo Sung; Jung, Hyun Chae

    2016-04-01

    Self-expanding metal stents (SEMS) have been used for the palliative treatment of malignant gastric outlet obstruction (GOO). The aim of this study was to evaluate the clinical outcomes of salvage SEMS for stent malfunction and to identify the prognostic factors for a longer patency. A total of 108 patients who underwent a secondary salvage SEMS placement for a primary stent malfunction were retrospectively reviewed at the Seoul National University Hospital between August 2004 and May 2013. The duration of patency for salvage SEMS was defined as the time between salvage SEMS placement and the recurrence of obstructive symptoms that were confirmed either endoscopically or radiologically. The technical and clinical success rates for salvage SEMS were 100 and 82.4% (95% confidence interval [CI] 74.0-89.0), respectively. A salvage SEMS malfunction occurred in 29 (26.9%) of the 108 patients. The median duration of patency for salvage SEMS was 59.5 days (range 3-928, 95% CI 73.7-118.3). Longer SEMS patencies of more than 60 days were significantly associated with palliative chemotherapy (odds ratio = 2.539, 95% CI 1.031-6.252, p = .043). For salvage SEMS, covered-uncovered stents had a longer patency duration, as compared with other combinations of primary and salvage stent types. Longer patency durations for salvage SEMS were associated with palliative chemotherapy after salvage SEMS insertion. Salvage SEMS could be a feasible and effective treatment for primary stent malfunction in malignant GOO.

  20. Relation of Nickel Allergy with in-Stent Restenosis in Patients Treated with Cobalt Chromium Stents.

    Science.gov (United States)

    Aliağaoğlu, Cihangir; Turan, Hakan; Erden, Ismail; Albayrak, Hülya; Ozhan, Hakan; Başar, Cengiz; Gürlevik, Zehra; Alçelik, Ayşegül

    2012-11-01

    In-stent restenosis (ISR) is the major limitation of percutaneous coronary stenting procedure. The elements like nickel, chromate and molybdenum are known to cause contact allergy. Hypersensitivity reaction, against these metal ions, may be one of the reasons of ISR. Cobalt chromium coronary stents, which are increasingly being used in percutaneous coronary interventions, have more nickel amount than the stainless steel stents. We aimed to investigate the association between nickel hypersensitivity reaction and ISR in patients treated with cobalt chromium coronary stents. Epicutaneous patch tests for nickel were applied to 31 patients who had undergone elective cobalt chromium coronary stent implantation and had ISR in control angiogram. Thirty patients, without ISR, were included as the control group. Patch test results and other clinical variables were compared. There was no statistically significant difference of the mean age, sex, body mass index, rate of hypercholesterolemia, diabetes, hypertension and smoking between the patients with and without ISR. All other lesion characteristics were similar in the 2 groups. According to the patch test results, 7 patients had nickel contact allergy. All of these patients were in the ISR group, which was statistically significant (pnickel allergy than the control group. Nickel allergy may play role in restenosis pathophysiology.

  1. Novel polycarbonate-based polyurethane elastomers: composition–property relationship

    Czech Academy of Sciences Publication Activity Database

    Špírková, Milena; Pavličevic, J.; Strachota, Adam; Poreba, Rafal; Bera, O.; Kaprálková, Ludmila; Baldrian, Josef; Šlouf, Miroslav; Lazić, N.; Budinski-Simendic, J.

    2011-01-01

    Roč. 47, č. 5 (2011), s. 959-972 ISSN 0014-3057 R&D Projects: GA ČR GAP108/10/0195 Institutional research plan: CEZ:AV0Z40500505 Keywords : polyurethane elastomer * polycarbonate diol * montmorillonite Subject RIV: CD - Macromolecular Chemistry Impact factor: 2.739, year: 2011

  2. Polyurethanes elastomers with amide chain extenders of uniform length

    NARCIS (Netherlands)

    van der Schuur, J.M.; Noordover, B.A.J.; Noordover, Bart; Gaymans, R.J.

    2006-01-01

    Toluene diisocyanate based polyurethanes with amide extenders were synthesized poly(propylene oxide) with a number average molecular weight of 2000 and endcapped with toluene diisocyanate was used as the polyether segment. The chain extenders were based on poly(hexamethylene terephthalamide):

  3. 78 FR 55641 - Polyurethane-Type Polymers; Tolerance Exemption

    Science.gov (United States)

    2013-09-11

    ...-Type Polymers; Tolerance Exemption AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule... polymers produced by the reaction of either 1,6-hexanediisocyanate; 2,4,4-trimethyl-1,6-hexanediisocyanate... (also known as polyurethane-type polymers), when used as an inert ingredient in a pesticide chemical...

  4. Synthesis and characterization of castor oil-based polyurethane for ...

    Indian Academy of Sciences (India)

    Polyurethane (PU) based on polyol, derived from castor oil has been synthesized and characterized for potential use as a base material for electrolytes. Transesterification process of castor oil formed a polyol with hydroxyl value of 190 mg KOH g–1 and molecular weight of 2786 g mol–1. The polyols together with 4 ...

  5. Synthesis and characterization of bio-based polyurethane from ...

    Indian Academy of Sciences (India)

    Benzoylated tannin prepared by benzoylation of cashewnut husk tannin, was treated with hexame-thylenediisocyanate in the presence of 1,4-butanediol as an extender to prepare thermosetting polyurethane. The sample was characterized using FT–IR and 13C NMR spectra. Thermal, morphological, physico-chemical and ...

  6. Optimization of polyurethane foam cube in enhancing the ...

    African Journals Online (AJOL)

    ... and 0.368 g respectively. For packing volume, 6% is the best since has highest attached microalgae biomass with yield 0.753 g, compared with 2%, 4%, 8% and 10% with yield 0.426 g, 0.577 g, 0.687 g and 0.644 g attached biomass respectively. Keywords: microalgae; chlorella vulgaris, polyurethane; attached biomass.

  7. Characterization studies of lower and non-TDI polyurethane encapsulants

    International Nuclear Information System (INIS)

    Wilson, M.H.

    1993-09-01

    Polyurethane prepolymers containing toluene diisocyanate (TDI) are used within the Nuclear Weapons complex for many adhesive and encapsulation applications. As part of a program for minimizing hazards to workers and the environment, TDI will be eliminated. This report presents evaluation of alternative encapsulants

  8. The use of polyurethane in coastal engineering models

    NARCIS (Netherlands)

    Verhagen, H.J.

    2014-01-01

    In physical model tests there is often a need of preventing stones from moving. This can be achieved by gluing the stones. Applying PBA (Polyurethane Bonded Agregate, e.g. Elastocoast) guarantees no moving stones, a normal permeability and a transportable model.

  9. Recycling Waste Polyurethane as a Carbon Resource in Ironmaking*

    African Journals Online (AJOL)

    Michael

    2017-06-01

    Jun 1, 2017 ... Globally, major avenues available for dealing with waste Poly-Urethane (PU) are disposal at landfill sites and incineration. However, PU contains high levels of carbon and hydrogen that can be recovered for use as reductant in metal extraction processes. In this work the use of post-consumer PU as ...

  10. Recycling Waste Polyurethane as a Carbon Resource in Ironmaking ...

    African Journals Online (AJOL)

    Globally, major avenues available for dealing with waste Poly-Urethane (PU) are disposal at landfill sites and incineration. However, PU contains high levels of carbon and hydrogen that can be recovered for use as reductant in metal extraction processes. In this work the use of post-consumer PU as reductant for the ...

  11. Mechanical and microwave absorbing properties of carbon-filled polyurethane

    Czech Academy of Sciences Publication Activity Database

    Kučerová, Z.; Zajíčková, L.; Buršíková, V.; Kudrle, V.; Eliáš, M.; Jašek, O.; Synek, P.; Matějková, Jiřina; Buršík, Jiří

    2009-01-01

    Roč. 40, č. 1 (2009), s. 70-73 ISSN 0968-4328 R&D Projects: GA ČR(CZ) GA202/05/0607 Institutional research plan: CEZ:AV0Z20650511; CEZ:AV0Z20410507 Keywords : carbon nanotubes * composite * polyurethane * mechanical properties Subject RIV: JI - Composite Materials Impact factor: 1.626, year: 2009

  12. Biodegradable injectable polyurethanes: synthesis and evaluation for orthopaedic applications.

    Science.gov (United States)

    Adhikari, Raju; Gunatillake, Pathiraja A; Griffiths, Ian; Tatai, Lisa; Wickramaratna, Malsha; Houshyar, Shadi; Moore, Tim; Mayadunne, Roshan T M; Field, John; McGee, Margaret; Carbone, Tania

    2008-10-01

    Biodegradable polyurethanes offer advantages in the design of injectable or preformed scaffolds for tissue engineering and other medical implant applications. We have developed two-part injectable prepolymer systems (prepolymer A and B) consisting of lactic acid and glycolic acid based polyester star polyols, pentaerythritol (PE) and ethyl lysine diisocyanate (ELDI). This study reports on the formulation and properties of a series of cross linked polyurethanes specifically developed for orthopaedic applications. Prepolymer A was based on PE and ELDI. Polyester polyols (prepolymer B) were based on PE and dl-lactic acid (PEDLLA) or PE and glycolic acid (PEGA) with molecular weights 456 and 453, respectively. Several cross linked porous and non-porous polyurethanes were prepared by mixing and curing prepolymers A and B and their mechanical and thermal properties, in vitro (PBS/37 degrees C/pH 7.4) and in vivo (sheep bi-lateral) degradation evaluated. The effect of incorporating beta-tricalcium phosphate (beta-TCP, 5 microns, 10 wt.%) was also investigated. The cured polymers exhibited high compressive strength (100-190 MPa) and modulus (1600-2300 MPa). beta-TCP improved mechanical properties in PEDLLA based polyurethanes and retarded the onset of in vitro and in vivo degradation. Sheep study results demonstrated that the polymers in both injectable and precured forms did not cause any surgical difficulties or any adverse tissue response. Evidence of new bone growth and the gradual degradation of the polymers were observed with increased implant time up to 6 months.

  13. Hyaluronan Immobilized Polyurethane as a Blood Contacting Material

    Directory of Open Access Journals (Sweden)

    Feirong Gong

    2010-01-01

    Full Text Available Hyaluronan (hyaluronic acid, HA was immobilized onto the surface of amino-functionalized polyurethane films with the goal of obtaining a novel kind of biomaterial which had the potential in blood-contacting applications. The amino-functionalized polyurethane was prepared by synthesized acidic polyurethane whose pendant carboxyl groups were treated with an excess amount of 1,3-diaminopropane in the presence of N,N-carbonyldiimidazole (CDI. Attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR, Raman spectroscopy (RS, scanning electron microscopy (SEM, and water contact angle measurement were used to confirm the surface changes at each step of treatment, both in morphologies and chemical compositions. APTT and PT results showed that HA immobilization could prolong the blood coagulation time, thus HA-immobilized polyurethane (PU-HA exhibited improved blood compatibility. Cytotoxicity analysis showed that the PU-HA films synthesized in this study were cytocompatible and could support human vein endothelial cells (HUVECs adhesion and proliferation.

  14. Characterization of Novel Castor Oil-Based Polyurethane Polymer Electrolytes

    Directory of Open Access Journals (Sweden)

    Salmiah Ibrahim

    2015-04-01

    Full Text Available Castor oil-based polyurethane as a renewable resource polymer has been synthesized for application as a host in polymer electrolyte for electrochemical devices. The polyurethane was added with LiI and NaI in different wt% to form a film of polymer electrolytes. The films were characterized by using attenuated total reflectance-Fourier transform infrared spectroscopy, dynamic mechanical analysis, electrochemical impedance spectroscopy, linear sweep voltammetry and transference number measurement. The highest conductivity of 1.42 × 10−6 S cm−1 was achieved with the addition of 30 wt% LiI and 4.28 × 10−7 S·cm−1 upon addition of 30 wt% NaI at room temperature. The temperature dependence conductivity plot indicated that both systems obeyed Arrhenius law. The activation energy for the PU-LiI and PU-NaI systems were 0.13 and 0.22 eV. Glass transition temperature of the synthesized polyurethane decreased from −15.8 °C to ~ −26 to −28 °C upon salts addition. These characterizations exhibited the castor oil-based polyurethane polymer electrolytes have potential to be used as alternative membrane for electrochemical devices.

  15. Polyurethanes with bio-based and recycled components

    Czech Academy of Sciences Publication Activity Database

    Beneš, Hynek; Vlček, T.; Černá, R.; Hromádková, Jiřina; Walterová, Zuzana; Svitáková, Romana

    2012-01-01

    Roč. 114, č. 1 (2012), s. 71-83 ISSN 1438-7697 R&D Projects: GA MPO 2A-2TP1/135 Institutional research plan: CEZ:AV0Z40500505 Keywords : natural oil * polyol * polyurethane Subject RIV: CD - Macromolecular Chemistry Impact factor: 2.266, year: 2012

  16. Utilization of natural oils for decomposition of polyurethanes

    Czech Academy of Sciences Publication Activity Database

    Beneš, Hynek; Černá, R.; Ďuračková, Andrea; Látalová, Petra

    2012-01-01

    Roč. 20, č. 1 (2012), s. 175-185 ISSN 1566-2543 R&D Projects: GA MPO 2A-2TP1/135 Institutional research plan: CEZ:AV0Z40500505 Keywords : polyurethane * oleochemical polyol * chemical recycling Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.495, year: 2012

  17. Synthesis and characterization of castor oil-based polyurethane

    Indian Academy of Sciences (India)

    Polyurethane (PU) based on polyol, derived from castor oil has been synthesized and characterized for potential use as a base material for electrolytes. Transesterification process of castor oil formed a polyol with hydroxyl value of 190 mg KOH g–1 and molecular weight of 2786 g mol–1. The polyols together with 4 ...

  18. Synthesis and characterization of castor oil based polyurethane ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. A series of interpenetrating polymer networks (IPNs) of castor oil based polyurethane/polyacrylo- nitrile (PU/PAN: 80/20, 60/40, 50/50, 40/60 and 20/80) were synthesized by condensation reaction of castor oil with methylene diisocyanate and acrylonitrile, employing benzoyl peroxide (BPO) and ethylene glycol ...

  19. Thermoplastic shape-memory polyurethanes based on natural oils

    Science.gov (United States)

    Saralegi, Ainara; Foster, E. Johan; Weder, Christoph; Eceiza, Arantxa; Corcuera, Maria Angeles

    2014-02-01

    A new family of segmented thermoplastic polyurethanes with thermally activated shape-memory properties was synthesized and characterized. Polyols derived from castor oil with different molecular weights but similar chemical structures and a corn-sugar-based chain extender (propanediol) were used as starting materials in order to maximize the content of carbon from renewable resources in the new materials. The composition was systematically varied to establish a structure-property map and identify compositions with desirable shape-memory properties. The thermal characterization of the new polyurethanes revealed a microphase separated structure, where both the soft (by convention the high molecular weight diol) and the hard phases were highly crystalline. Cyclic thermo-mechanical tensile tests showed that these polymers are excellent candidates for use as thermally activated shape-memory polymers, in which the crystalline soft segments promote high shape fixity values (close to 100%) and the hard segment crystallites ensure high shape recovery values (80-100%, depending on the hard segment content). The high proportion of components from renewable resources used in the polyurethane formulation leads to the synthesis of bio-based polyurethanes with shape-memory properties.

  20. Synthesis and characterization of castor oil-based polyurethane for ...

    Indian Academy of Sciences (India)

    Administrator

    Abstract. Polyurethane (PU) based on polyol, derived from castor oil has been synthesized and characterized for potential use as a base material for electrolytes. Transesterification process of castor oil formed a polyol with hydroxyl value of 190 mg KOH g–1 and molecular weight of 2786 g mol–1. The polyols together with.

  1. Interfacial contributions in lignocellulosic firber-reinforced polyurethane composites

    Science.gov (United States)

    Timothy G. Rials; Michael P. Wolcott; John M. Nassar

    2001-01-01

    Whereas lignocellulosic fibers have received considerable attention as a reinforcing agent in thermoplastic composites, their applicability to reactive polymer systems remains of considerable interest. The hydroxyl-rich nature of natural lignocellulosic fibers suggests that they are particularly useful in thermsetting systems such as polyurethanes. To further this...

  2. Interfacial contributions in lignocellulosic fiber-reinforced polyurethane composites

    Science.gov (United States)

    Timothy G. Rials; Michael P. Wolcott; John M. Nassar

    2001-01-01

    Whereas lignocellulosic fibers have received considerable attention as a rein- forcing agent in thermoplastic composites, their applicability to reactive polymer systems remains of considerable interest. The hydroxyl-rich nature of natural lignocellulosic fibers suggests that they are particularly useful in thermosetting systems such as polyurethanes. To further this...

  3. Influence of polyols on properties of bio-based polyurethanes

    Indian Academy of Sciences (India)

    The thermal degradation of all the three elastomers starts almost at 270◦C ... Experimental. 2.1 Materials and methods. Cardanol was procured from m/s Sathya Cashew Pvt. Ltd.,. Chennai. Formaldehyde (40% solution) for formylation and methanol for .... C to determine solubility parameter of polyurethane samples.

  4. Creation of individual ideally shaped stents using multi-slice CT: in vitro results from the semi-automatic virtual stent (SAVS) designer

    International Nuclear Information System (INIS)

    Hyodoh, Hideki; Katagiri, Yoshimi; Hyodoh, Kazusa; Akiba, Hidenari; Hareyama, Masato; Sakai, Toyohiko

    2005-01-01

    To plan stent-grafting for thoracic aortic aneurysm with complicated morphology, we created a virtual stent-grafting program [Semi Automatic Virtual Stent (SAVS) designer] using three-dimensional CT data. The usefulness of the SAVS designer was evaluated by measurement of transformed anatomical and straight stents. Curved model images (source, multi-planer reconstruction and volume rendering) were created, and a hollow virtual stent was produced by the SAVS designer. A straight Nitinol stent was transformed to match the curved configuration of the virtual stent. The accuracy of the anatomical stent was evaluated by experimental strain phantom studies in comparison with the straight stent. Mean separation length was 0 mm in the anatomical stent [22 mm outer diameter (OD)] and 5 mm in the straight stent (22 mm OD). The straight stent strain voltage was four times that of the anatomical stent at the stent end. The anatomical stent is useful because it fits the curved structure of the aorta and reduces the strain force compared to the straight stent. The SAVS designer can help to design and produce the anatomical stent. (orig.)

  5. Studies on polyurethane adhesives and surface modification of hydrophobic substrates

    Science.gov (United States)

    Krishnamoorthy, Jayaraman

    This thesis work deals with (a) Curing of reactive, hot-melt polyurethane adhesives and (b) Adsorption studies using different interactions. Research on polyurethanes involves characterization of polyurethane prepolymers and a novel mechanism to cure isocyanate-terminated polyurethane prepolymer by a "trigger" mechanism. Curing of isocyanate-terminated polyurethane prepolymers has been shown to be influenced by morphology and environmental conditions such as temperature and relative humidity. Although the initial composition, final morphology and curing kinetics are known, information regarding the intermediate prepolymer mixture is yet to be established. Polyurethane prepolymers prepared by the reaction of diisocyanates with the primary hydroxyls of polyester diol (PHMA) and secondary hydroxyls of polyether diol (PPG) were characterized. The morphology and crystallization kinetics of a polyurethane prepolymer was compared with a blend of PPG prepolymer (the product obtained by the reaction of PPG with diisocyanate) and a PHMA prepolymer (the product obtained by the reaction of PHMA with diisocyanate) to study the effect of copolymer formed in the polyurethane prepolymer on the above-mentioned properties. Although the morphology of the polyurethane prepolymer is determined in the first few minutes of application, the chemical curing of isocyanate-terminated prepolymer occurs over hours to days. In the literature, different techniques are described to follow the curing kinetics. But there is no established technique to control the curing of polyurethane prepolymer. To make the curing process independent of environmental factors, a novel approach using a trigger mechanism was designed and implemented by using ammonium salts as curing agents. Ammonium salts that are stable at room temperature but decompose on heating to yield active hydrogen-containing compounds, NH3 and H2O, were used as 'Trojan horses' to cure the prepolymer chemically. Research on adsorption

  6. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Directory of Open Access Journals (Sweden)

    Kensuke Tashiro, MD

    2017-11-01

    Conclusions:. Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery.

  7. Oesophageal cancer and experience with endoscopic stent ...

    African Journals Online (AJOL)

    Background: Oesophageal cancer often presents in advanced stages not amenable to surgical resection. In such patients, palliation of dysphagia remains the mainstay of management. oBjectives: To determine the burden of advanced oesophageal cancer and to document the experience with endoscopic metal stent.

  8. Metal stents for malignant biliary obstruction

    NARCIS (Netherlands)

    Laméris, J. S.; Stoker, J.

    1994-01-01

    The main problem in the palliative treatment of malignant biliary obstruction is recurrent jaundice and cholangitis due to clogging of the endoprostheses. Large-bore metal stents, which can be placed using small-sized delivery systems, have been recognized as an important gain. Their use has

  9. Circadian Variation in Coronary Stent Thrombosis

    NARCIS (Netherlands)

    Mahmoud, Karim D.; Lennon, Ryan J.; Ting, Henry H.; Rihal, Charanjit S.; Holmes, David R.

    Objectives We sought to determine the circadian, weekly, and seasonal variation of coronary stent thrombosis. Background Other adverse cardiovascular events such as acute myocardial infarction are known to have higher incidences during the early morning hours, Mondays, and winter months. Methods The

  10. Oesophageal cancer and experience with endoscopic stent ...

    African Journals Online (AJOL)

    Background: Oesophageal cancer often presents in advanced stages not amenable to surgical resection. In such patients, palliation of dysphagia remains the mainstay of management. Objectives: To determine the burden of advanced oesophageal cancer and to document the experience with endoscopic metal stent ...

  11. Hyperperfusion syndrome after carotid stent angioplasty

    International Nuclear Information System (INIS)

    Grunwald, I.Q.; Politi, M.; Reith, W.; Krick, C.; Karp, K.; Zimmer, A.; Struffert, T.; Kuehn, A.L.; Papanagiotou, P.; Roth, C.; Haass, A.

    2009-01-01

    This study assesses the incidence and causes of hyperperfusion syndrome occurring after carotid artery stenting (CAS). We retrospectively reviewed the clinical database of 417 consecutive patients who were treated with CAS in our department to identify patients who developed hyperperfusion syndrome and/or intracranial hemorrhage. Magnetic resonance imaging (MRI) including fluid-attenuated inversion recovery and diffusion-weighted imaging was performed before and after CAS in 269 cases. A Spearman's rho nonparametric correlation was performed to determine whether there was a correlation between the occurrence/development of hyperperfusion syndrome and the patient's age, degree of stenosis on the stented and contralateral side, risk factors such as diabetes, smoking, hypertension, adiposity, gender and fluoroscopy time, and mean area of postprocedural lesions as well as preexisting lesions. Significance was established at p < 0.05. Of the 417 carotid arteries stented and where MRI was also completed, we found hyperperfusion syndrome in 2.4% (ten cases). Patients who had preexisting brain lesions (previous or acute stroke) were at a higher risk of developing hyperperfusion syndrome (p = 0.022; Spearman's rho test). We could not validate any correlation with the other patient characteristics. Extensive microvascular disease may be a predictor of hyperperfusion syndrome after carotid stent placement. We believe that further studies are warranted to predict more accurately which patients are at greater risk of developing this often fatal complication. (orig.)

  12. Oesphageal Stenting for palliation of malignant mesothelioma

    Directory of Open Access Journals (Sweden)

    Rahamim Joseph

    2008-01-01

    Full Text Available Abstract Dyspahgia in patients with malignant mesothelioma is usually due to direct infiltration of the eosophagus by the tumour. It can be distressing for the patient and challenging for the physician to treat. We describe three cases in which this condition has been successfully palliated with self expanding esophageal stents.

  13. [Magnetic resonance imaging features of tear outflow and structural changes of the lacrimal sac and nasolacrimal duct in normal subjects with eyes closed].

    Science.gov (United States)

    Si, J R; Zhang, Y L

    2018-03-11

    Objective: To investigate the static and dynamic features of the normal lacrimal sac (LS)-nasolacrimal duct (NLD), and find out if tear flows while the subject is in supine position with eyes closed. Methods: Cross-sectional study. Healthy volunteers and patients whose head were examined by MRI in Guangdong Provincial Hospital of Integrated Traditional Chinese and Western Medicine with normal LS-NLD were recruited. The normal lacrimal ducts of the candidates were scanned, while candidates remained in supine position, by static or dynamic imaging procedures with a 1.5T MRI system, which adopted the thinnest slice thickness, consecutive sections (no spacing) and two scanning planes (axial and coronal planes of LS-NLD). The static and dynamic imaging procedures were done in June and July 2014 and October 2015, respectively. The static imaging was performed with conventional T(2)WI, contrast-enhanced 3D FIESTA-C, contrast-enhanced T(1)WI and heavy T(2)WI pulse sequences under normal physiological condition, and 104 eyes with normal LS-NLD from 39 patients and 13 healthy volunteers (21 male and 31 female) aged 10 to 75 years were scanned with the static procedure. The dynamic imaging was done with heavy T(2)WI pulse sequence. The coronal dynamic imaging was done only after 0.9% NaCl was instilled in the conjunctival sacs, and 20 eyes with normal LS-NLD of 10 volunteers (6 male and 4 female) aged 23 to 53 years were scanned with the coronal dynamic procedure. The axial dynamic imaging was done under normal physiological condition and after 0.9% NaCl was instilled in the conjunctival sacs respectively, and 20 eyes with normal LS-NLD of 10 volunteers (8 male and 2 female) aged 20 to 40 years were scanned with the axial dynamic procedure. The incidences on the axial dynamic imaging under the two conditions were compared with χ(2) test. Results: A total of 104 eyes with normal LS-NLD (52 candidates) were scanned with the static imaging sequences. In all LS-NLDs, an

  14. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    International Nuclear Information System (INIS)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.

    2003-01-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  15. Thermoplastic polyurethane (TPU)/polyolefin (PO) blends

    Science.gov (United States)

    Lu, Qiwei

    Thermoplastic polyurethane (TPU) is a very important material with high versatility and superior physical properties. Melt blending TPU with metallocene polyolefin (PO) can lower TPU cost and improve polyolefin properties like abrasion resistance, adhesion, and paintability. Since TPU and non-polar PO blends are completely immiscible, efficient compatibilizers become the key issue and remain challenging. My main thesis work is to develop and study compatibilized TPU/PO blends. Although reactive compatibilization is considered the most efficient method, fast interfacial reactions between highly reactive functional groups are necessary to generate compatibilizers within usually short processing time. It is known that the urethane linkage (carbamate -NHCOO-) in TPU can reversibly dissociate to generate highly reactive isocyanates at melt temperatures. To find out the best reactive compatibilization, three approaches were employed on different molecular scales: (1) model urethane compound (dibutyl & dioctyl 4,4'-methylenebis(phenyl carbamate)) and small functional molecule (primary amine, secondary amine, hydroxyl, acid, anhydride, and epoxide) reactions at 200°C monitored by nuclear magnetic resonance and Fourier-transform infrared to examine the basic chemistry; (2) short, model TPU's with different chemical structures blended with functional polymers including poly(ethylene glycol) and polybutadiene to explore the effect of interface in immiscible mixtures; (3) melt blending of a commercial TPU with polypropylene (PP), further involving more complicated morphology, using different types of functional PP's (note: amine functional PP's were prepared by melt amination) as compatibilizers followed by rheological, morphological, thermal, and mechanical characterizations. Besides the core thesis project on TPU blends, other related work that has been accomplished includes: (1) adhesion between TPU and PP; (2) rheological properties of TPU; (3) block copolymer formation

  16. Auxetic polyurethane foam: Manufacturing and processing analysis

    Science.gov (United States)

    Jahan, Md Deloyer

    Materials with negative Poisson's ratio are referred to as auxetic materials. They are different from conventional materials in their deformation behavior when responding to external stresses. The cross-section of the materials widens in the lateral direction when being stretched in the longitudinal direction and becomes narrower when being compressed longitudinally. While a number of natural auxetic materials exist, most auxetic materials are synthetic. They show interesting properties and have potential in several important applications. Auxetic materials exhibit better mechanical properties than conventional materials such as enhanced indentation resistance, shear resistance, toughness, damping and energy absorption capacity, sound absorption, variable permeability and capability of producing complex curvature. These properties are beneficial in a wide range of applications including personal protective equipments, sound absorbers, packaging, smart filtration, drug delivery, tissue scaffolding, seat cushioning, etc. A wide range of auxetic materials has been synthesized. They include different polymers, metals, composites and ceramics. Among these, auxetic polyurethane (PU) foam is one of the most widely studied types of auxetic materials. Auxetic PU foams are usually fabricated by altering the microstructure of conventional foams and the unusual mechanical properties originate from the deformation characteristics of the microstructures. Three most important processing parameters in fabricating auxetic PU foam that dictate auxetic behavior are processing temperature, heating time and volumetric compression ratio. This study addresses several important issues in the manufacturing and characterization of auxetic PU foam. First, an improved automatic measuring technique has been developed to determine Poisson's ratio of auxetic PU foam. The technique involves development of a Matlab based image processing program. The second part of the study includes an

  17. Synthesis of polyurethane/clay nanocomposites based palm oil polyol coating

    Directory of Open Access Journals (Sweden)

    Teuku Rihayat

    2015-12-01

    Full Text Available In this study, we investigated the Polyurethane paint based on palm oil with the addition of nanoparticles montmorillonite as a heat-resistant. The composites with 1 wt%, 3 wt% and 5 wt% of bentonite filler content obtained by synthesizing in situ were investigated and compared to the neat polyurethane matrix material. The processing of bentonite for montmorillonite was done through several stages including: sedimentation, ultrasonication, dried, sieved with a 200 mesh sieve, then characterized. Untreated MMT were isolated and modified with CTAB. The addition of MMT into polyurethane, as much as 5% wt, can increase the heat as evidenced by the TGA test. The TGA results indicated an enhanced thermal stability, as compared to the neat polyurethane. The onset degradation of neat polyurethane and weight reduction began at a temperature of 50-150°C and completely decomposed at the temperatures of 380°C and for PU MKS-MMT reduction, the initial weight started at a temperature of 150-200°C in 5 %wt and decomposed in the end at a temperature of 490°C. In this research, we also tested the gloss adhesive polyurethane with the addition of MMT; the result stated that the addition of 5%wt MMT can improve the adhesion of polyurethane. The addition of MMT in polyurethane can also enhance the gloss polyurethane compared with polyurethane coated without the addition of MMT.

  18. Novel route of synthesis for cellulose fiber-based hybrid polyurethane

    Science.gov (United States)

    Ikhwan, F. H.; Ilmiati, S.; Kurnia Adi, H.; Arumsari, R.; Chalid, M.

    2017-07-01

    Polyurethanes, obtained by the reaction of a diisocyanate compound with bifunctional or multifunctional reagent such as diols or polyols, have been studied intensively and well developed. The wide range modifier such as chemical structures and molecular weight to build polyurethanes led to designs of materials that may easily meet the functional product demand and to the extraordinary spreading of these materials in market. Properties of the obtained polymer are related to the chemical structure of polyurethane backbone. A number polyurethanes prepared from biomass-based monomers have been reported. Cellulose fiber, as a biomass material is containing abundant hydroxyl, promising material as chain extender for building hybrid polyurethanes. In previous researches, cellulose fiber was used as filler in synthesis of polyurethane composites. This paper reported a novel route of hybrid polyurethane synthesis, which a cellulose fiber was used as chain extender. The experiment performed by reacting 4,4’-Methylenebis (cyclohexyl isocyanate) (HMDI) and polyethylene glycol with variation of molecular weight to obtained pre-polyurethane, continued by adding micro fiber cellulose (MFC) with variation of type and composition in the mixture. The experiment was evaluated by NMR, FTIR, SEM and STA measurement. NMR and FTIR confirmed the reaction of the hybrid polyurethane. STA showed hybrid polyurethane has good thermal stability. SEM showed good distribution and dispersion of sorghum-based MFC.

  19. Self-made Palmaz stent: an experimental swine model study

    International Nuclear Information System (INIS)

    He Shicheng; Teng Gaojun; Guo Jinhe; Fang Wen

    2000-01-01

    Objective: To investigate the histologic changes and physicochemical stability of self-made Palmaz stent placed in swine arteries. Methods: The self-made Palmaz stent was made of 316L stainless steel wire. Nine stents were respectively placed within internal carotid, renal and iliac arteries of six pigs. Pigs were euthanized at intervals of 0.5, 1 and 3 months respectively and angiography were performed. Immediately followed by light and electro scanning microscopy for the stent zones. Results: All stents were successfully implanted in the target arteries and were patent shown in the angiographic examination immediately after the stent placement. Eight stents (8/9) remained patent at the time before euthanasia. No migration of stent were shown in the follow-up angiography. Light and electron scanning microscopy showed that the surface of the stents was covered by a thin layer of endothelial cells 2 weeks after the procedure and completely covered after 4 weeks. No inflammation occurred. Conclusions: The self-made Palmaz stent has good physicochemical stability and histocompatibility with easy placement, rather long term patency, histopathologic stability and thus the promising for clinical application

  20. Computational design analysis for deployment of cardiovascular stents

    International Nuclear Information System (INIS)

    Tammareddi, Sriram; Sun Guangyong; Li Qing

    2010-01-01

    Cardiovascular disease has become a major global healthcare problem. As one of the relatively new medical devices, stents offer a minimally-invasive surgical strategy to improve the quality of life for numerous cardiovascular disease patients. One of the key associative issues has been to understand the effect of stent structures on its deployment behaviour. This paper aims to develop a computational model for exploring the biomechanical responses to the change in stent geometrical parameters, namely the strut thickness and cross-link width of the Palmaz-Schatz stent. Explicit 3D dynamic finite element analysis was carried out to explore the sensitivity of these geometrical parameters on deployment performance, such as dog-boning, fore-shortening, and stent deformation over the load cycle. It has been found that an increase in stent thickness causes a sizeable rise in the load required to deform the stent to its target diameter, whilst reducing maximum dog-boning in the stent. An increase in the cross-link width showed that no change in the load is required to deform the stent to its target diameter, and there is no apparent correlation with dog-boning but an increased fore-shortening with increasing cross-link width. The computational modelling and analysis presented herein proves an effective way to refine or optimise the design of stent structures.

  1. Are bio-absorbable stents the future of SFA treatment?

    Science.gov (United States)

    Peeters, P; Keirse, K; Verbist, J; Deloose, K; Bosiers, M

    2010-02-01

    Several limitations inherent to the implantation of a metallic device, such as the occurrence of in-stent re-stenosis, in an arterial lumen intuitively explain the interest for developing bio-absorbable stents. Two main types of bio-absorbable stents currently exist: polymer stents and metallic stents. To date, no studies with bio-absorbable stents have been conducted in the superficial femoral artery (SFA). Because of their strut thickness and lack of radial force, polymer stents are no good candidates for endovascular use. Absorbable metal stents (AMS) do have the potential to perform well for artery treatment, although current evidence from in-human coronary and infrapopliteal studies yield unsatisfactory results. Drastic technological improvements are mandatory before AMS can be considered for every day practice. Yet, it is our belief that further development of other metal and non-metal bio-absorbable stents, with or without drug-coating, may lead to the creation of the ultimate SFA stent.

  2. Design Investigation on Applicable Mesh Structures for Medical Stent Applications

    Science.gov (United States)

    Asano, Shoji; He, Jianmei

    2017-11-01

    In recent years, utilization of medical stents is one of effective treatments for stenosis and occlusion occurring in a living body’s lumen indispensable for maintenance of human life such as superficial femoral artery (SFA) occlusion. However, there are concerns about the occurrence of fatigue fractures caused by stress concentrations, neointimal hyperplasia and the like due to the shape structure and the manufacturing method in the conventional stents, and a stent having high strength and high flexibility is required. Therefore, in this research, applicable mesh structures for medical stents based on the design concepts of high strength, high flexibility are interested to solve various problem of conventional stent. According to the shape and dimensions of SFA occlusion therapy stent and indwelling delivery catheter, shape design of the meshed stent are performed using 3-dimensional CAD software Solid Works first. Then analytical examination on storage characteristics and compression characteristics of such mesh structure applied stent models were carried out through finite element analysis software ANSYS Workbench. Meshed stent models with higher strength and higher flexibility with integral molding are investigated analytically. It was found that the storage characteristics and compression characteristics of meshed stent modles are highly dependent on the basic mesh shapes with same surface void ratio. Trade-off relationship between flexibility and storage characteristics is found exited, it is required to provide appropriate curvatures during basic mesh shape design.

  3. Factors leading to tracheobronchial self-expandable metallic stent fracture.

    Science.gov (United States)

    Chung, Fu-Tsai; Lin, Shu-Min; Chen, Hao-Cheng; Chou, Chun-Liang; Yu, Chih-Teng; Liu, Chien-Ying; Wang, Chun-Hua; Lin, Horng-Chyuan; Huang, Chien-Da; Kuo, Han-Pin

    2008-11-01

    This retrospective study was to determine factors that contribute to self-expandable metallic stent fracture in patients with tracheobronchial disease. From 2001 to 2006, 139 patients (age, 62.1 +/- 15.4 years; range, 23-87 years) with benign (n = 62) and malignant (n = 77) tracheobronchial disease received 192 Ultraflex (Boston Scientific, Natick, Mass) self-expandable metallic stents (98 in patients with benign disease and 94 in patients with malignant disease). Seventeen fractured self-expandable metallic stents were found; the incidence was 12.2% (17/139 patients) among patients with tracheobronchial disease. Tortuous airway (odds ratio, 4.06; 95% confidence interval, 1.04-18.34; P = .04) independently predicted self-expandable metallic stent fracture. Most self-expandable metallic stent fractures (64.7%, 11/17) were detected 500 to 1000 days after self-expandable metallic stent implantation. Clinical presentations for patients with fractured self-expandable metallic stents included dyspnea exacerbation (70.6%, 12/17) and cough (23.5%, 4/17). Self-expandable metallic stent fracture is not uncommon in patients with tracheobronchial disease. Tortuous airway is an independent predictor for it. Although management of the fractured self-expandable metallic stent in our study was feasible and safe, self-expandable metallic stents should be restricted to a more select population.

  4. Surgical stent for dental implant using cone beam CT images

    International Nuclear Information System (INIS)

    Choi, Hyung Soo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2010-01-01

    The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

  5. Computational design analysis for deployment of cardiovascular stents

    Science.gov (United States)

    Tammareddi, Sriram; Sun, Guangyong; Li, Qing

    2010-06-01

    Cardiovascular disease has become a major global healthcare problem. As one of the relatively new medical devices, stents offer a minimally-invasive surgical strategy to improve the quality of life for numerous cardiovascular disease patients. One of the key associative issues has been to understand the effect of stent structures on its deployment behaviour. This paper aims to develop a computational model for exploring the biomechanical responses to the change in stent geometrical parameters, namely the strut thickness and cross-link width of the Palmaz-Schatz stent. Explicit 3D dynamic finite element analysis was carried out to explore the sensitivity of these geometrical parameters on deployment performance, such as dog-boning, fore-shortening, and stent deformation over the load cycle. It has been found that an increase in stent thickness causes a sizeable rise in the load required to deform the stent to its target diameter, whilst reducing maximum dog-boning in the stent. An increase in the cross-link width showed that no change in the load is required to deform the stent to its target diameter, and there is no apparent correlation with dog-boning but an increased fore-shortening with increasing cross-link width. The computational modelling and analysis presented herein proves an effective way to refine or optimise the design of stent structures.

  6. [Drug-eluting stent thrombosis and its pharmacological prevention].

    Science.gov (United States)

    Pershukov, I V; Batyraliev, T A

    2007-01-01

    The problem of drug eluting stents (DES) safety has been actively discussed throughout 2006 because of increase of frequency of development of late stent thromboses which were noted during almost 2 years after stenting. In December 2006 US Food and Drug Administration (FDA) advisory panel acknowledged increase of development of late stent thrombosis. At the same time FDA accepted new definition of stent-thrombosis suggested by the Academic Research Consortium. According to this definition thrombosis can be definite, probable and possible. Any unexplained death before end of follow-up in a trial should be considered thrombosis related. Recalculation of thrombosis rate using this definition caused pronounced increase of this parameter in previously conducted trials. Thrombosis rate rose from 0,6 to 3,3% for bare metal stents, from 0,8 to 3,6% for sirolimus eluting stents and from 1,3 to 3,5% for paclitaxel eluting stents. Professional cardiological and angiographical societies (ACC, AHA, SCAI) responding to FDA advisory panel published their proofs and vision of the problem of stent thrombosis. In February 2007 ACC, AHA, SCAI, American College of Surgeons and Association of Dentists published scientific bulletin in which described preventive measures aimed at lowering of risk of thrombosis development. This document contains strict recommendation to continue double antithrombotic therapy with aspirin and clopidogrel for 12 months after implantation of DES or abandonment of the use of this type of stents when long term double antithrombotic therapy is not possible.

  7. Surgical stent for dental implant using cone beam CT images

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyung Soo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [Department of Oral and Maxillofacial Radiology, School of Dentistry, Kung Hee University, Seoul (Korea, Republic of)

    2010-12-15

    The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

  8. The Modification of Polyurethane Foams Using New Boroorganic Polyols (II) Polyurethane Foams from Boron-Modified Hydroxypropyl Urea Derivatives

    Science.gov (United States)

    2014-01-01

    The work focuses on research related to determination of application possibility of new, ecofriendly boroorganic polyols in rigid polyurethane foams production. Polyols were obtained from hydroxypropyl urea derivatives esterified with boric acid and propylene carbonate. The influence of esterification type on properties of polyols and next on polyurethane foams properties was determined. Nitrogen and boron impacts on the foams' properties were discussed, for instance, on their physical, mechanical, and electric properties. Boron presence causes improvement of dimensional stability and thermal stability of polyurethane foams. They can be applied even at temperature 150°C. Unfortunately, introducing boron in polyurethanes foams affects deterioration of their water absorption, which increases as compared to the foams that do not contain boron. However, presence of both boron and nitrogen determines the decrease of the foams combustibility. Main impact on the decrease combustibility of the obtained foams has nitrogen presence, but in case of proper boron and nitrogen ratio their synergic activity on the combustibility decrease can be easily seen. PMID:24587721

  9. Ureteral stent retrieval using the crochet hook technique in females.

    Directory of Open Access Journals (Sweden)

    Takashi Kawahara

    Full Text Available INTRODUCTION: We developed a method for ureteral stent removal in female patients that requires no cystoscopy or fluoroscopic guidance using a crochet hook. In addition, we also investigated the success rate, complications and pain associated with this procedure. METHODS: A total of 40 female patients (56 stents underwent the removal of ureteral stents. All procedures were carried out with the patients either under anesthesia, conscious sedation, or analgesic suppositories as deemed appropriate for each procedure including Shock Wave Lithotripsy (SWL, Ureteroscopy (URS, Percutaneous Nephrolithotomy (PCNL, and ureteral stent removal. At the time of these procedures, fluoroscopy and/or cystoscopy were prepared, but they were not used unless we failed to successfully remove the ureteral stent using the crochet hook. In addition, matched controls (comprising 50 stents which were removed by standard ureteral stent removal using cystoscopy were used for comparison purposes. RESULTS: A total of 47 of the 56 stents (83.9% were successfully removed. In addition, 47 of 52 (90.4% were successfully removed except for two migrated stents and two heavily encrusted stents which could not be removed using cystoscopy. Ureteral stent removal using the crochet hook technique was unsuccessful in nine patients, including two encrustations and two migrations. Concerning pain, ureteral stent removal using the crochet hook technique showed a lower visual analogue pain scale (VAPS score than for the standard technique using cystoscopy. CONCLUSIONS: Ureteral stent removal using a crochet hook is considered to be easy, safe, and cost effective. This technique is also easy to learn and is therefore considered to be suitable for use on an outpatient basis.

  10. Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention.

    Science.gov (United States)

    Uthamaraj, Susheil; Tefft, Brandon J; Hlinomaz, Ota; Sandhu, Gurpreet S; Dragomir-Daescu, Dan

    2015-09-18

    Rapid endothelialization of cardiovascular stents is needed to reduce stent thrombosis and to avoid anti-platelet therapy which can reduce bleeding risk. The feasibility of using magnetic forces to capture and retain endothelial outgrowth cells (EOC) labeled with super paramagnetic iron oxide nanoparticles (SPION) has been shown previously. But this technique requires the development of a mechanically functional stent from a magnetic and biocompatible material followed by in-vitro and in-vivo testing to prove rapid endothelialization. We developed a weakly ferromagnetic stent from 2205 duplex stainless steel using computer aided design (CAD) and its design was further refined using finite element analysis (FEA). The final design of the stent exhibited a principal strain below the fracture limit of the material during mechanical crimping and expansion. One hundred stents were manufactured and a subset of them was used for mechanical testing, retained magnetic field measurements, in-vitro cell capture studies, and in-vivo implantation studies. Ten stents were tested for deployment to verify if they sustained crimping and expansion cycle without failure. Another 10 stents were magnetized using a strong neodymium magnet and their retained magnetic field was measured. The stents showed that the retained magnetism was sufficient to capture SPION-labeled EOC in our in-vitro studies. SPION-labeled EOC capture and retention was verified in large animal models by implanting 1 magnetized stent and 1 non-magnetized control stent in each of 4 pigs. The stented arteries were explanted after 7 days and analyzed histologically. The weakly magnetic stents developed in this study were capable of attracting and retaining SPION-labeled endothelial cells which can promote rapid healing.

  11. Numerical investigations of the mechanical properties of braided vascular stents.

    Science.gov (United States)

    Fu, Wenyu; Xia, Qixiao; Yan, Ruobing; Qiao, Aike

    2018-01-01

    Braided stents, such as Pipeline Embolization Device (PED; ev3 Neurovascular, Irvine, CA, USA), are commonly used to treat cerebral aneurysms. However, little information is available on the compression and bending characteristics of such stents. This paper investigates how geometrical parameters of braided stents influence their radial compression and bending characteristics. Six groups of braided stent models with different braiding angles, numbers of wires and wire diameters are constructed. Parametric analyses of these models are conducted using Abaqus/Explicit software. The numerical results of a finite element analysis are validated by comparison with data of theoretical analysis. The results show that the radial stiffness is not uniform along the longitudinal direction of the stent. When the braiding angle increases from 30° to 75°, the minimum radial deformation decreases from 0.85 mm to 0.0325 mm (at a pressure of 500 Pa, for 24 braided wires). When the wire diameter increases from 0.026 mm to 0.052 mm, the minimum radial deformation decreases from 0.65 mm to 0.055 mm (at a pressure of 500 Pa and a braiding angle of 60°, for 24 braided wires). Frictions don't affect stent diameter and its axial length when braided stent is crimping, but the friction must be considered when it is related to the radial pressure required for compression the braided stent. Compared with commonly used intracranial stents, a braided stent with geometrical parameters close to PED stent has a smaller radial stiffness but a considerably greater longitudinal flexibility. The results of this analysis of braided stents can help in the design and selection of flow diverter stents for clinical treatment of cerebral aneurysms.

  12. Solvent-free fabrication of micro-porous polyurethane amide and polyurethane-urea scaffolds for repair and replacement of the knee-joint meniscus

    NARCIS (Netherlands)

    Spaans, C.J; Belgraver, V.W.; Rienstra, O.; de Groot, J.H; Veth, R.P.H.; Penning, J.P

    2000-01-01

    New porous polyurethane urea and polyurethane amide scaffolds for meniscal reconstruction have been developed in a solvent-free process. As soft segments, copolymers of 50/50 L-lactide/epsilon-caprolactone have been used. After terminating the soft segment with diisocyanates, chain extension was

  13. Biocompatibility of coronary stent materials: effect of electrochemical polishing

    Energy Technology Data Exchange (ETDEWEB)

    Scheerder, I. de [University Hospital Leuven (Belgium). Dept. of Cardiology; Sohier, J.; Froyen, L.; Humbeeck, J. van [Louvain Univ. (Belgium). Dept. of Metallurgy and Materials Engineering; Verbeken, E. [University Hospital Leuven (Belgium). Dept. of Pathology

    2001-02-01

    Percutaneous Transluminal Coronary Revascularization (PTCR) is now a widely accepted treatment modality for atherosclerotic coronary artery disease. Current multicenter randomized trials comparing PTCR with the more invasive Coronary Artery Bypass Grafting could not show long-term significant survival differences. During the last two decades progress has been made to further optimize PTCR. The most logic approach to treat atherosclerotic coronary narrowings is to remove the atherosclerotic material using especially developed devices. Several trials, however, could not show a significant beneficial outcome after use of these devices compared to plain old balloon angioplasty. Another approach was to implant a coronary prothesis (stent), scaffolding the diseased coronary artery after PTCA. This approach resulted in a decreased restenosis rate at follow-up. The beneficial effects of stenting, however, was not found to be related to the inhibition of the neointimal cellular proliferation after vascular injury, but simply to be the mechanical result of overstretching of the treated vessel segment. The most important remaining clinical problem after stenting remains the neointimal hyperplasia within the stent, resulting in a significant stent narrowing in 13 to 30% of patients. Further efforts to improve the clinical results of coronary stenting should focus on the reduction of this neointimal hyperplasia. Neointimal hyperplasia after stent implantation results from (1) a healting response to the injury caused by the stent implantation and (2) a foreign body response to the stent itself. Factors that seem to influence the neointimal hyperplastic response are genetic, local disease related, stent delivery related and stent related factors. Biocompatibilisation of coronary stents by looking for more biocompatible metal alloys, optimized surface characteristics and optimized stent designs should result in a better late patency. Furthermore drug eluting and radioactive stents

  14. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model

    Science.gov (United States)

    Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R

    2011-01-01

    Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363

  15. Plastic strains during stent deployment have a critical influence on the rate of corrosion in absorbable magnesium stents.

    Science.gov (United States)

    Galvin, Emmet; Cummins, Christy; Yoshihara, Shoichiro; Mac Donald, Bryan J; Lally, Caitríona

    2017-08-01

    Magnesium stents are a promising candidate in the emerging field of absorbable metallic stents (AMSs). In this study, the mechanical and corrosion performance of dog-bone specimens and a specific stent design of a magnesium alloy, WE43, are assessed experimentally in terms of their corrosion behaviour and mechanical integrity. It is shown that plastic strains that are induced in the struts of the stent during stent deployment have a critical influence in directing subsequent corrosion behaviour within the material. In addition, the deployment and scaffolding characteristics of the magnesium stent are elucidated and contrasted with those of a commercial stainless steel stent. The magnesium stent is found to support higher levels of cyclic strain amplitude than the stainless steel stent, even prior to degradation, and this may play a role in reducing in-stent restenosis. This study provides new insights into the experimental performance of a current AMS design and material whilst demonstrating the critical influence of plastic strain on the corrosion performance and scaffolding ability of an AMS.

  16. Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V)

    DEFF Research Database (Denmark)

    Christiansen, Evald Høj; Jensen, Lisette Okkels; Thayssen, Per

    2013-01-01

    Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer...

  17. Comparison of closed-cell and hybrid-cell stent designs in carotid artery stenting: clinical and procedural outcomes

    Directory of Open Access Journals (Sweden)

    Ersan TatlI

    2017-05-01

    Full Text Available Introduction: Carotid artery stenting (CAS is a promising alternative to surgery in high-risk patients. However, the impact of stent cell design on outcomes in CAS is a matter of continued debate. Aim : To compare the periprocedural and clinical outcomes of different stent designs for CAS with distal protection devices. Material and methods : All CAS procedures with both closed- and hybrid-cell stents performed at our institution between February 2010 and December 2015 were analyzed retrospectively. Adverse events were defined as death, major stroke, minor stroke, transient ischemic attack and myocardial infarction. Periprocedural and 30-day adverse events and internal carotid artery (ICA vasospasm rates were compared between the closed-cell and hybrid-cell stent groups. Results : The study included 234 patients comprising 146 patients with a closed-cell stent (Xact stent, Abbott Vascular (mean age: 68.5 ±8.6; 67.1% male and 88 patients with a hybrid-cell stent (Cristallo Ideale, Medtronic (mean age: 67.2 ±12.8; 68.2% male. There was no significant difference between the groups with respect to periprocedural or 30-day adverse event rates. While there was no difference in terms of tortuosity index between the groups, there was a higher procedural ICA vasospasm rate in the closed-cell stent group (35 patients, 23% compared with the hybrid-cell stent group (10 patients, 11% (p = 0.017. Conclusions : The results of this study showed no significant difference in the clinical adverse event rates after CAS between the closed-cell stent group and the hybrid-cell stent group. However, procedural ICA vasospasm was more common in the closed-cell stent group.

  18. Comparison of Acute Recoil between Bioabsorbable Poly-L-lactic Acid XINSORB Stent and Metallic Stent in Porcine Model

    Directory of Open Access Journals (Sweden)

    Yizhe Wu

    2012-01-01

    Full Text Available Objective. To investigate acute recoil of bioabsorbable poly-L-lactic acid (PLLA stent. Background. As newly developed coronary stent, bioabsorbable PLLA stent still encountered concern of acute stent recoil. Methods. Sixteen minipigs were enrolled in our study. Eight PLLA XINSORB stents (Weite Biotechnology Co., Ltd., China and eight metallic stents (EXCEL, Jiwei Co., Ltd. China were implanted into coronary arteries. Upon quantitative coronary angiography analysis, acute absolute recoil was defined as the difference between mean diameter of inflated balloon (X and mean lumen diameter of stent immediately after deployment (Y, while acute percent recoil was defined as (X−Y/X and expressed as a percentage. Intravascular ultrasound (IVUS was performed immediately after implantation and 24 hours later to compare cross-sectional area (CSA between two groups and detect stent malapposition or collapse. Results. Acute absolute recoil in XINSORB and EXCEL was 0.02±0.13 mm and −0.08±0.08 mm respectively (P=0.19. Acute percent recoil in XINSORB and EXCEL was 0.66±4.32% and −1.40±3.83%, respectively (P=0.45. CSA of XINSORB was similar to that of EXCEL immediately after implantation, so was CSA of XINSORB at 24-hours followup. Within XINSORB group, no difference existed between CSA after implantation and CSA at 24-hours followup. No sign of acute stent malapposition was detected by IVUS. Conclusions. The acute stent recoil of XINSORB is similar to that of EXCEL. No acute stent malapposition or collapse appeared in both kinds of stent. This preclinical study was designed to provide preliminary data for future studies of long-term efficacy and safety of XINSORB stent.

  19. Implante de stent dentro de stent recém-implantado em ponte de veia safena para otimização do resultado angiográfico Stenting a stent in saphenous vein graft to optimize the angiographic result

    Directory of Open Access Journals (Sweden)

    Antonio Esteves Fº

    1998-03-01

    Full Text Available Mulher de 60 anos, com angina progressiva e revascularização do miocárdio, há oito anos, com ponte de veia safena para coronária direita e anastomose de artéria mamaria esquerda para artéria descendente anterior. Submetida a implante de stent Gianturco-Roubin II em terço proximal da ponte de veia safena para artéria coronária direita, com resultado insatisfatório pela persistência de lesão residual, provavelmente, decorrente de prolapso para dentro da luz de material aterosclerótico através dos coils. Foi implantado outro stent (Palmaz-Schatz biliar dentro do stent GRII com sucesso e ótimo resultado angiográfico. Um 2º stent Palmaz-Schatz biliar foi implantado em lesão distal no corpo da ponte, ultrapassando os dois stents, anteriormente implantados, com sucesso. Em algumas situações, implante de stent dentro de outro stent é recurso útil para otimização de resultado angiográfico do implante de um stent.A 60 year-old woman with progressive angina who had been submitted to saphenous bypass-graft to right coronary artery and a left mammary artery graft to anterior descending artery eight years previously, underwent implantation of a Gianturco Roubin II stent in the proximal third of the saphenous vein graft. The result was suboptimal by persistence of a residual stenosis probably due to prolapse of atherosclerotic material through the coil spaces. Another stent (Palmaz-Schatz biliar stent was implanted at the previously stented site with no residual stenosis. Another Palmaz-Schatz biliar stent was successfully implanted in the distal body of the graft to treat another lesion (passing through the previously stents without difficulty. Stenting a stent, in selected situations, is a useful tool to optimize the angiographic result of stent implantation.

  20. Isolation and characterization of a bacterium which utilizes polyester polyurethane as a sole carbon and nitrogen source.

    Science.gov (United States)

    Nakajima-Kambe, T; Onuma, F; Kimpara, N; Nakahara, T

    1995-06-01

    Various soil samples were screened for the presence of microorganisms which have the ability to degrade polyurethane compounds. Two strains with good polyurethane degrading activity were isolated. The more active strain was tentatively identified as Comamonas acidovorans. This strain could utilize polyester-type polyurethanes but not the polyether-type polyurethanes as sole carbon and nitrogen sources. Adipic acid and diethylene glycol were probably the main degradation products when polyurethane was supplied as a sole carbon and nitrogen source. When ammonium nitrate was used as nitrogen source, only diethylene glycol was detected after growth on polyurethane.

  1. Esophageal stent migration can lead to intestinal obstruction

    Science.gov (United States)

    Karatepe, Oguzhan; Acet, Ersin; Altiok, Merih; Battal, Muharrem; Adas, Gokhan; Karahan, Servet

    2009-01-01

    Background: Self-expanding metallic stents are the devices of choice in the treatment of malign or benign strictures of the esophagus. Stent migration is a well-known complication of this procedure. Aims: We report a case of intestinal obstruction caused by esophageal stent migration, in which surgical intervention was used. Methods: A 65-year-old woman, who had a medical history of gastric cancer operations and esophageal stent applications, was admitted to our emergency department with a 48-hour history of abdominal pain, nausea and vomiting. An emergency laparotomy was performed and the migrated stent causing intestinal obstruction was removed. Results: The patient recovered without incident and was discharged on postoperative day 3. Conclusion: This case illustrates that esophageal stent migration has to be considered as a potential life-threatening complication. PMID:22666672

  2. Stone Formation and Fragmentation in Forgotten Ureteral Double J Stent

    Directory of Open Access Journals (Sweden)

    Okan Bas

    2014-02-01

    Full Text Available Aim: Nowadays, ureteral stents play an essential role in various endourological and open surgical procedures and common procedures performed in daily urological practice. However, stents can cause significant complications such as migration, infection, fragmentation, stone formation and encrustation, especially when forgotten for a long period. Objectives: We present our experience in endoscopic management of forgotten ureteral stents with a brief review of current literature. Case presentation: A total of 2 patients with forgotten ureteral stents were treated with endourological approaches in our department. Indwelling durations were 18 months and 36 months. After treatment both patients were stone and stent free. Conclusion: An endourological approach is effective for stent and stone removal after a single anesthesia session with minimal morbidity and short hospital stay. However, therapeutic strategy is also determined by the technology available. The best treatment would be the prevention of this complication by providing detailed patient education.

  3. Angioplasty and stenting to treat occlusive vascular disease.

    Science.gov (United States)

    Caplan, Louis R; Meyers, Philip M; Schumacher, H Christian

    2006-01-01

    The advent of effective percutaneous treatment of occlusive vascular lesions by angioplasty and stenting is one of the most important contributions to medical care early in the 21st century. Evaluation of angioplasty and stenting procedures is still in a very early phase. New types of stents and other technologies and devices are being continuously developed and there is a definite learning curve. The experience, training, and number of procedures clearly relate to outcomes, and many different specialists are still learning and so far have not had optimal experience. This review provides an overview of studies that have examined the efficacy of stenting in conjunction with balloon angioplasty for carotid atherosclerosis compared with endarterectomy. Also discussed are angioplasty/stenting of other neck arteries and intracranial arteries and the key issues surrounding percutaneous intervention, including patient selection criteria, clinical assessment of lesions most suitable for treatment, the use of distal protective devices and drug-eluting stents, and recommendations for physician selection.

  4. Percutaneous antegrade ureteric stent removal using a rigid alligator forceps.

    LENUS (Irish Health Repository)

    Given, M F

    2008-12-01

    To evaluate the safety and efficacy of percutaneous antegrade ureteric stent removal using a rigid alligator forceps. Twenty patients were included in our study. Indications for ureteric stent insertion included stone disease (n = 7), malignancy (n = 8) and transplant anastomotic strictures (n = 5). Stent retrieval was carried out for proximal stent placement\\/migration in seven patients and encrustation in the remaining 13. Twenty-two stents were successfully retrieved in 20 patients. There was one technical failure (5%). There were no major complications. We had four minor complications, which included nephrostomy site pain (n = 2), periprocedural sepsis (n = 1) and a small urinoma (n = 1). All patients settled with conservative management. Percutaneous radiologically guided antegrade ureteric stent removal with an alligator forceps is safe and effective, particularly when initial surgical removal has failed.

  5. Metallic intratracheal stent application on relapsing polychondritis with severe tracheobronchial malacia

    International Nuclear Information System (INIS)

    Ao Guokun; Zhao Weiguo; Guo Qinyun; Huang Qin

    2007-01-01

    Objective: To evaluate the therapeutic and adverse effects of metallic intratracheal stent placement in relapsing polychondritis with severe tracheobronchial malaeia. Methods: Five tracheal stents had been implanted in three patients with tracheobronchial malaeia. One patient was implanted with two tubular stents in trachea and one 'Y' shaped stent for bilateral bronchi. Another patient used a tubular stent in total tracheal segment. The last patient used a tubular stent in the upper segment of trachea. Results: All the stents were implanted successfully with obvious improvement of dyspnea after the treatment. Conclusions: Metallic intratracheal stent placement can really relieve symptoms and improve the life quality in patients with tracheobronchial malacia caused by relapsing polychondritis. (authors)

  6. Safety and efficacy of everolimus-eluting stents for bare-metal in-stent restenosis

    International Nuclear Information System (INIS)

    Ota, Hideaki; Mahmoudi, Michael; Torguson, Rebecca; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D.; Waksman, Ron

    2015-01-01

    Objective: The aim of this study was to compare the safety and efficacy of the everolimus-eluting stents (EES) with the paclitaxel-eluting stent (PES) and sirolimus-eluting stent (SES) for the treatment of bare-metal in-stent restenosis. Background: The optimal treatment for bare-metal in-stent restenosis remains controversial. Methods: The study cohort comprised 322 consecutive patients (543 lesions) who presented with bare-metal in-stent restenosis to our institution and underwent coronary artery stent implantation with EES (114 patients; 181 lesions), PES (65 patients; 116 lesions) and SES (143 patients; 246 lesions). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac events (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors except for age and chronic kidney disease. The 1-year analyzed clinical parameters were similar in the three groups: death (EES = 3.5%, PES = 4.6%, SES = 4.2%; p = 0.94), MI (EES = 3.5%, PES = 6.3%, SES = 2.1%; p = 0.31), TLR (EES = 9.8%, PES = 9.5%, SES = 5.7%; p = 0.42), TVR (EES = 14.3%, PES = 11.1%, SES = 11.3%; p = 0.74), definite ST (EES = 0.9%, PES = 3.1%, SES = 3.5%; p = 0.38) and MACE (EES = 14.0%, PES = 15.4%, SES = 10.5%; p = 0.54). Male gender (hazard ratio = 0.47; 95% confidence interval = 0.25–0.88) and number of treated lesions (hazard ratio = 1.47; 95% confidence interval = 1.06–2.05) were found to be independent predictors of MACE. Conclusion: The results of the present study indicate that EES may provide similar safety and efficacy as first generation DES for the treatment of patients presenting with bare-metal in-stent restenosis

  7. Safety and efficacy of everolimus-eluting stents for bare-metal in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Torguson, Rebecca; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-04-15

    Objective: The aim of this study was to compare the safety and efficacy of the everolimus-eluting stents (EES) with the paclitaxel-eluting stent (PES) and sirolimus-eluting stent (SES) for the treatment of bare-metal in-stent restenosis. Background: The optimal treatment for bare-metal in-stent restenosis remains controversial. Methods: The study cohort comprised 322 consecutive patients (543 lesions) who presented with bare-metal in-stent restenosis to our institution and underwent coronary artery stent implantation with EES (114 patients; 181 lesions), PES (65 patients; 116 lesions) and SES (143 patients; 246 lesions). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac events (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors except for age and chronic kidney disease. The 1-year analyzed clinical parameters were similar in the three groups: death (EES = 3.5%, PES = 4.6%, SES = 4.2%; p = 0.94), MI (EES = 3.5%, PES = 6.3%, SES = 2.1%; p = 0.31), TLR (EES = 9.8%, PES = 9.5%, SES = 5.7%; p = 0.42), TVR (EES = 14.3%, PES = 11.1%, SES = 11.3%; p = 0.74), definite ST (EES = 0.9%, PES = 3.1%, SES = 3.5%; p = 0.38) and MACE (EES = 14.0%, PES = 15.4%, SES = 10.5%; p = 0.54). Male gender (hazard ratio = 0.47; 95% confidence interval = 0.25–0.88) and number of treated lesions (hazard ratio = 1.47; 95% confidence interval = 1.06–2.05) were found to be independent predictors of MACE. Conclusion: The results of the present study indicate that EES may provide similar safety and efficacy as first generation DES for the treatment of patients presenting with bare-metal in-stent restenosis.

  8. Biomaterial based novel polyurethane adhesives for wood to wood and metal to metal bonding

    OpenAIRE

    Patel,Mitesh Ramanlal; Shukla,Jignesh Markandray; Patel,Natvarbhai Khodidas; Patel,Ketan Haribhai

    2009-01-01

    Polyurethane adhesives made from synthetic chemicals are non-biodegradable, costly and difficult to find raw materials from local market. To avoid solid pollution problem, cost effectiveness and easy availability of raw materials, biomaterials based polyurethane adhesives are used in current industrial interest. Direct use of castor oil in polyurethane adhesive gives limited hardness. Modification on active sites of castor oil to utilize double bond of unsaturated fatty acid and carboxyl grou...

  9. Stenting vs. balloon angioplasty with provisional stenting for the treatment of vessels with small reference diameter.

    Science.gov (United States)

    Lemos, Pedro A; Martinez, Eulogio E; Quintella, Edgard; Harrell, Lari C; Ramires, Jose A F; Ribeiro, Expedito E; da Gama, Marcus N; Horta, Pedro E; Kajita, Luiz J; Esteves, Antonio; Perin, Marco A; Soares, Paulo R; Zalc, Silvio; Palacios, Igor F

    2002-03-01

    A consecutive series of interventions in vessels with reference diameter < or = 2.75 mm was retrospectively analyzed according to preprocedure strategy: balloon angioplasty with provisional stenting (PTCA group, 73 patients) and primary stenting (PS group, 122 patients). In the PS group, there were more patients with single-vessel disease (54.1% vs. 37.0%; P = 0.021), less patients with three-vessel disease (9.0% vs. 24.7%; P = 0.003), more LAD interventions (54.9% vs. 31.5; P = 0.002), and less left circumflex interventions (22.1% vs. 45.2%; P < 0.001). Reference diameter was larger in the PS group (2.28 +/- 0.35 mm vs. 2.11 +/- 0.36 mm; P = 0.001). Provisional stenting was performed in 39.7% of PTCA group. At long-term outcome, the incidence of composite major events was similar between the PTCA and the PS groups (20.5% vs. 17.2%, respectively; P = NS). Treatment of small vessels with balloon dilatation and provisional stenting or with primary stenting yielded similar late outcomes. Operators' choice of treatment strategy was based on particular angiographic characteristics. Copyright 2002 Wiley-Liss, Inc.

  10. Caracterización de la restenosis de stents coronarios convencionales y liberadores de medicamentos en pacientes incluidos en el registro DRug Eluting STent (DREST Characterization of conventional coronary stents restenosis and drug eluting stents in patients included in the Drug Eluting Stent Registry (DREST

    Directory of Open Access Journals (Sweden)

    Jorge A Arroyave C

    2012-06-01

    Full Text Available Introducción y objetivos: los stents convencionales presentan tasas de restenosis intrastent entre 10% y 60%, mientras los stents liberadores de fármacos alcanzan el 10%. Para Latinoamérica, no hay reportes de restenosis intrastent en comparación con los stents convencionales y los stents liberadores de fármacos. En este estudio se describen aspectos asociados a este evento en pacientes atendidos en un centro de alta complejidad en Colombia. Métodos: análisis retrospectivo de pacientes con restenosis intrastent incluidos en el registro DRug ELuting STent (DREST entre los años 1994 y 2011, en el que se compararon características basales, datos técnicos y supervivencia de los pacientes con stent convencional y stent liberador de fármacos. Resultados: se evidenció restenosis intrastent en 269 con stent convencional (11,5% y en 65 con stent liberador de fármacos (12,2%, sin diferencias significativas al comparar por género (p=0,983 o edad (p=0,55. La dislipidemia fue el factor de riesgo más significativo asociado a la restenosis intrastent de los stents liberadores de fármacos (pIntroduction and Objectives: Bare metal stents have stent restenosis rates between 10% and 60%, while drug-eluting stents reach 10%. In Latin America, there are no reports of stent restenosis between bare-metal stents and drug eluting stents. This study describes aspects associated with this event in patients treated at a center of high complexity in Colombia. Methods: Retrospective analysis of patients with stent restenosis included in the Drug Eluting Stent Registry (DREST between 1994 and 2011, which compared baseline characteristics, technical data and survival of patients with bare metal stents and drug eluting stents. Results: We found stent restenosis with bare metal stents in 269 patients (11.5% and in 65 with drug-eluting stent (12.2% without significant differences between gender (p = 0.983 or age (p = 0 , 55. Dyslipidemia was the most significant

  11. Stenting for curved lesions using a novel curved balloon: Preliminary experimental study.

    Science.gov (United States)

    Tomita, Hideshi; Higaki, Takashi; Kobayashi, Toshiki; Fujii, Takanari; Fujimoto, Kazuto

    2015-08-01

    Stenting may be a compelling approach to dilating curved lesions in congenital heart diseases. However, balloon-expandable stents, which are commonly used for congenital heart diseases, are usually deployed in a straight orientation. In this study, we evaluated the effect of stenting with a novel curved balloon considered to provide better conformability to the curved-angled lesion. In vitro experiments: A Palmaz Genesis(®) stent (Johnson & Johnson, Cordis Co, Bridgewater, NJ, USA) mounted on the Goku(®) curve (Tokai Medical Co. Nagoya, Japan) was dilated in vitro to observe directly the behavior of the stent and balloon assembly during expansion. Animal experiment: A short Express(®) Vascular SD (Boston Scientific Co, Marlborough, MA, USA) stent and a long Express(®) Vascular LD stent (Boston Scientific) mounted on the curved balloon were deployed in the curved vessel of a pig to observe the effect of stenting in vivo. In vitro experiments: Although the stent was dilated in a curved fashion, stent and balloon assembly also rotated conjointly during expansion of its curved portion. In the primary stenting of the short stent, the stent was dilated with rotation of the curved portion. The excised stent conformed to the curved vessel. As the long stent could not be negotiated across the mid-portion with the balloon in expansion when it started curving, the mid-portion of the stent failed to expand fully. Furthermore, the balloon, which became entangled with the stent strut, could not be retrieved even after complete deflation. This novel curved balloon catheter might be used for implantation of the short stent in a curved lesion; however, it should not be used for primary stenting of the long stent. Post-dilation to conform the stent to the angled vessel would be safer than primary stenting irrespective of stent length. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  12. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events

    DEFF Research Database (Denmark)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph

    2014-01-01

    eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. PRIMARY OUTCOMES: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite...... a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P... coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. CONCLUSIONS: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt...

  13. Comparison of Recanalization and In-Stent Stenosis Between the Low-Profile Visualized Intraluminal Support Stent and Enterprise Stent-Assisted Coiling for 254 Intracranial Aneurysms.

    Science.gov (United States)

    Feng, Xin; Qian, Zenghui; Liu, Peng; Zhang, Baorui; Wang, Luyao; Guo, Erkang; Wen, Xiaolong; Xu, Wenjuan; Jiang, Chuhan; Wu, Zhongxue; Li, Youxiang; Liu, Aihua

    2018-01-01

    To compare the rates of recanalization and in-stent stenosis between the Enterprise (EP) and low-profile visualized intraluminal support (LVIS) stent deployments for intracranial aneurysms (IAs), and the factors associated therein. Between June 2014 and July 2016, 142 patients with a total of 161 IAs were treated by LVIS stent-assisted coiling and 111 patients with a total of 142 IAs were treated by EP stent-assisted coiling at our institution. Procedure-related complications, angiographic follow-up results, and clinical outcomes were analyzed statistically. The rates of initially complete and near-complete IA occlusion immediately after the procedure were similar in the LVIS and EP groups (94.3% vs. 89.9%; P = 0.275). On follow-up, complete and near-complete occlusion rates and recanalization rates were also similar in the 2 groups (96.6% vs. 92.1%; P =0.330 and 8.0% vs. 13.5%; P = 0.245, respectively). On logistic regression analysis, a higher size ratio (SR) was significantly associated with the recanalization of aneurysms in the EP group, but not in the LVIS group. The rate of moderate to severe in-stent stenosis was lower in the LVIS group (10.2%) than in the EP group (16.8%), but the difference was not statistically significant (P = 0.198). Our data show acceptable rates of complete and near-complete occlusion with both the LVIS and EP stents. LVIS stents were associated with lower rates of recanalization and in-stent stenosis, but the difference was not significant. Higher SR (≥2) was a significant predictor of recanalization in IAs treated with EP stents, but not in those treated with LVIS stents. Copyright © 2017. Published by Elsevier Inc.

  14. Stents in paediatric and adult congenital interventional cardiac catheterization.

    Science.gov (United States)

    Hascoët, Sebastien; Baruteau, Alban; Jalal, Zakaria; Mauri, Lucia; Acar, Philippe; Elbaz, Meyer; Boudjemline, Younes; Fraisse, Alain

    2014-01-01

    A 'stent' is a tubular meshed endoprosthesis that has contributed to the development of interventional catheterization over the past 30 years. In congenital heart diseases, stents have offered new solutions to the treatment of congenital vessel stenosis or postsurgical lesions, to maintain or close shunt patency, and to allow transcatheter valve replacement. First, stents were made of bare metal. Then, stent frameworks evolved to achieve a better compromise between radial strength and flexibility. However, almost all stents used currently in children have not been approved for vascular lesions in children and are therefore used 'off-label'. Furthermore, the inability of stents to follow natural vessel growth still limits their use in low-weight children and infants. Recently, bioresorbable stents have been manufactured and may overcome this issue; they are made from materials that may dissolve or be absorbed in the body. In this review, we aim to describe the history of stent development, the technical characteristics of stents used currently, the clinical applications and results, and the latest technological developments and perspectives in paediatric and adult congenital cardiac catheterization. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  15. [Finite Element Analysis of Intravascular Stent Based on ANSYS Software].

    Science.gov (United States)

    Shi, Gengqiang; Song, Xiaobing

    2015-10-01

    This paper adopted UG8.0 to bulid the stent and blood vessel models. The models were then imported into the finite element analysis software ANSYS. The simulation results of ANSYS software showed that after endothelial stent implantation, the velocity of the blood was slow and the fluctuation of velocity was small, which meant the flow was relatively stable. When blood flowed through the endothelial stent, the pressure gradually became smaller, and the range of the pressure was not wide. The endothelial shear stress basically unchanged. In general, it can be concluded that the endothelial stents have little impact on the flow of blood and can fully realize its function.

  16. Which criteria demand additive stenting during catheter-directed thrombolysis?

    DEFF Research Database (Denmark)

    Bækgaard, N; Just, S; Foegh, P

    2014-01-01

    obstructive lesions of the iliac veins are the most important contributors. Stenting has been known for 15 to 20 years. The first publication on CDT in 1991 was combined with ballooning the iliac vein, an additive procedure which has been abandoned as an isolated procedure. This chapter will discuss selection......, indication, such as an iliac compression syndrome, and outcome of iliac stenting in combination with CDT. The reported frequency of stenting used after CDT is very inconsistent, therefore this will be discussed in details. It is concluded that selection for stenting is of the greatest importance, when CDT...

  17. Percutaneous nephrostomy and antegrade ureteral stenting: technique - indications - complications

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, Klaus A. [Klagenfurt General Hospital, Department of Radiology, Klagenfurt (Austria); Portugaller, Horst R. [University Hospital of Graz, Department of Radiology, Graz (Austria)

    2006-09-15

    In this review the technique, indication for and complications of percutaneous nephrostomy (PCN) and antegrade ureter stent insertion are described. In the majority of the cases PCN is performed to relieve urinary obstruction, which can be of benign or malignant nature. Another indication for PCN is for treatment of urinary fistulas. PCN can be performed under ultrasound and/or fluoroscopic guidance, with a success rate of more than 90%. The complication rate is approximately 10% for major and minor complications together and 4-5% for major complications only. Percutaneous antegrade double-J stent insertion usually is performed if retrograde ureter stenting has not been successful. However, especially in malignant obstructions, the success rate for antegrade stenting is higher than for retrograde transvesical double-J stent insertion. In the case of severe infection and bleeding after PCN JJ-stent insertion may be contraindicated so long as there is no sufficient concomitant drainage via a PCN. Lower urinary tract dysfunction should be excluded before stent placement. The complication rate is 2-4%. Consequent stent surveillance with regular stent exchange is mandatory. (orig.)

  18. Protein losing enteropathy secondary to a pulmonary artery stent

    Directory of Open Access Journals (Sweden)

    Narayanswami Sreeram

    2012-01-01

    Full Text Available A 2-year-old patient with hypoplastic left heart syndrome presented 6 months following Fontan completion with protein-losing enteropathy (PLE. He had undergone stent implantation in the left pulmonary artery after the Norwood procedure, followed by redilation of the stent prior to Fontan completion. Combined bronchoscopic and catheterization studies during spontaneous breathing confirmed left bronchial stenosis behind the stent, and diastolic systemic ventricular pressure during expiration of 25 mm Hg. We postulate that the stent acts as a valve, against which the patient generates high expiratory pressures, which are reflected in the ventricular diastolic pressure. This may be the cause of PLE.

  19. Metallic Ureteric Stents in Malignant Ureteric Obstruction: a Systematic Review.

    Science.gov (United States)

    Khoo, C C K; Abboudi, H; Cartwright, R; El-Husseiny, T; Dasgupta, R

    2018-02-02

    The effectiveness of metallic stents in the management of malignant ureteric obstruction (MUO) is unclear. This systematic review evaluates the use of four commercially available metallic stents (Resonance, Memokath 051, Uventa and Allium URS). Twenty-one studies met eligibility criteria. Overall success rates ranged from 88% for the Allium stent to 65% for Memokath 051. Resonance demonstrated the lowest migration rate (1%). Uventa had the lowest obstruction rate (6%). Metallic ureteric stents offer a viable alternative in the management of MUO. Further high quality studies are required to assess cost effectiveness and refine specific indications based on aetiology and level of the ureteric obstruction. Copyright © 2018. Published by Elsevier Inc.

  20. Pulmonary Arterial Stent Implantation in an Adult with Williams Syndrome

    International Nuclear Information System (INIS)

    Reesink, Herre J.; Henneman, Onno D. F.; Delden, Otto M. van; Biervliet, Jules D.; Kloek, Jaap J.; Reekers, Jim A.; Bresser, Paul

    2007-01-01

    We report a 38-year-old patient who presented with pulmonary hypertension and right ventricular dysfunction due to pulmonary artery stenoses as a manifestation of Williams syndrome, mimicking chronic thromboembolic pulmonary hypertension. The patient was treated with balloon angioplasty and stent implantation. Short-term follow-up showed a good clinical result with excellent patency of the stents but early restenosis of the segments in which only balloon angioplasty was performed. These stenoses were subsequently also treated successfully by stent implantation. Stent patency was observed 3 years after the first procedure

  1. Percutaneous nephrostomy and antegrade ureteral stenting: technique - indications - complications

    International Nuclear Information System (INIS)

    Hausegger, Klaus A.; Portugaller, Horst R.

    2006-01-01

    In this review the technique, indication for and complications of percutaneous nephrostomy (PCN) and antegrade ureter stent insertion are described. In the majority of the cases PCN is performed to relieve urinary obstruction, which can be of benign or malignant nature. Another indication for PCN is for treatment of urinary fistulas. PCN can be performed under ultrasound and/or fluoroscopic guidance, with a success rate of more than 90%. The complication rate is approximately 10% for major and minor complications together and 4-5% for major complications only. Percutaneous antegrade double-J stent insertion usually is performed if retrograde ureter stenting has not been successful. However, especially in malignant obstructions, the success rate for antegrade stenting is higher than for retrograde transvesical double-J stent insertion. In the case of severe infection and bleeding after PCN JJ-stent insertion may be contraindicated so long as there is no sufficient concomitant drainage via a PCN. Lower urinary tract dysfunction should be excluded before stent placement. The complication rate is 2-4%. Consequent stent surveillance with regular stent exchange is mandatory. (orig.)

  2. Radiologic placement of metallic esophageal stents: preliminary experience

    International Nuclear Information System (INIS)

    Good, S.; Asch, M.R.; Jaffer, N.; Casson, A.G.

    1997-01-01

    To assess the usefulness of covered, self expanding metallic stents for alleviating stricture associated with malignant esophageal lesions. Patients and methods: Self-expanding metallic stents were placed in 10 patients with dysphagia related to stricture caused by malignant esophageal lesions. The stents were placed fluoroscopically with local anesthesia, and patency of the esophageal lumen was assessed by barium study after the procedure. The patients were then followed clinically. Results: In all 10 cases patency of the lumen was renewed after stent placement. After the procedure 9 of the patients could tolerate a normal or near-normal diet; in the other patient esophageal perforation occurred, and clinical deterioration prevented oral intake of food. In one patient, 2 stents were needed because of the length of the stricture. Two patients experienced reflux after placement of the stent across the gastro-esophageal junction. Another patient had asymptomatic aspiration after stent placement in the proximal esophagus. In 2 patients, symptoms associated with tracheoesophageal fistula were relieved after placement of the stents. Six of the 10 patients died; mean survival after the procedure was 12 (range 1 to 56) weeks. The other 4 patients were alive at the time of writing, having survived for a mean of 7.5 (range 2 to 13) weeks; all of these patients tolerated a near-normal diet. Conclusions: The placement of covered, self-expanding metallic stents is a quick, effective method of palliating dysphagia related to stricture caused by malignant esophageal lesions. (author)

  3. Next-generation drug-eluting stents in coronary artery disease: focus on everolimus-eluting stent (Xience V®

    Directory of Open Access Journals (Sweden)

    Imad Sheiban

    2008-02-01

    Full Text Available Imad Sheiban1, Gianluca Villata1, Mario Bollati1, Dario Sillano1, Marzia Lotrionte2, Giuseppe Biondi-Zoccai11Interventional Cardiology, Division of Cardiology, University of Turin, Turin, Italy; 2Institute of Cardiology, Catholic University, Rome, ItalyAbstract: Percutaneous coronary revascularization has been a mainstay in the management of coronary artery disease since its introduction in the late 1970s. Bare-metal stents and, more recently, first-generation drug-eluting stents (DES, such as sirolimus-eluting (Cypher® and paclitaxel-eluting stents (Taxus®, have further improved results of percutaneous coronary intervention (PCI by improving early results and reducing the risk of restenosis. There is currently debate on the safety of these first-generation DES, given the potential for late stent thrombosis, especially after discontinuation of dual antiplatelet therapy. There are well known caveats on the performance of their respective metallic stent platforms, delivery, and dilation systems, and polymer coatings. Second-generation DES, such as zotarolimus-eluting (Endeavor® and everolimus-eluting stents (Xience V®, have recently become available in the USA and/or Europe. The Xience V stent holds the promise of superior anti-restenotic efficacy as well as long-term safety. In addition, this stent is based on the Multi-link platform and delivery system. Recently available data already suggest the superiority of the Xience V stent in comparison to the Taxus stent in terms of prevention of restenosis, without significant untoward events. Nonetheless, the number of patients studied and the follow-up duration are still too limited to enable definitive conclusions. Only indirect meta-analyses can be used to date to compare the Xience V with the Cypher. This systematic review tries to provide a concise and critical appraisal of the data in support of the Xience V everolimus-eluting stent.Keywords: coronary artery disease, everolimus, percutaneous

  4. Development of bacterially resistant polyurethane for coating medical devices

    International Nuclear Information System (INIS)

    Roohpour, Nima; Moshaverinia, Alireza; Wasikiewicz, Jaroslaw M; Paul, Deepen; Vadgama, Pankaj; Wilks, Mark; Millar, Michael

    2012-01-01

    Polyurethanes have been widely used in medicine for coating and packaging implantable and other medical devices. Polyether-urethanes, in particular, have superior mechanical properties and are biocompatible, but in common with other medical materials they are susceptible to microbial film formation. In this study, polyether-urethane was end-capped with silver lactate and silver sulfadiazine functional groups to produce a bacterially resistant polymer without sacrificing the useful mechanical properties of the polyether-polyurethane. The silver ions were covalently incorporated into the polymer during chain extension of the prepolymer. The functionalized polymers were structurally characterized by light scattering, electron microscopy, NMR, FTIR and Raman spectroscopy. Mechanical properties, hydrophilicity, in vitro stability and antibacterial action of polymers were also investigated. Results indicate that both silver salts were successfully incorporated into the polymer structure without significant effect on mechanical properties, whilst conferring acceptable bacterial resistance.

  5. Extraction kinetics of uranium (VI) with polyurethane foam

    International Nuclear Information System (INIS)

    Huang, Ting-Chia; Chen, Dong-Hwang; Huang, Shius-Dong; Huang, Ching-Tsven; Shieh, Mu-Chang.

    1993-01-01

    The extraction kinetics of uranium(VI) from aqueous nitrate solution with polyether-based polyurethane foam was investigated in a batch reactor with automatic squeezing. The extraction curves of uranium(VI) concentration in solution vs. extraction time exhibited a rather rapid exponential decay within the first few minutes, followed by a slower exponential decay during the remaining period. This phenomenon can be attributed to the presence of two-phase structure, hard segment domains and soft segment matrix in the polyurethane foam. A two-stage rate model expressed by a superposition of two exponential curves was proposed, according to which the experimental data were fitted by an optimization method. The extraction rate of uranium (VI) was also found to increase with increasing temperature, nitrate concentration, and hydration of the cation of nitrate salt. (author)

  6. Properties of rigid polyurethane foams filled with glass microspheres

    Science.gov (United States)

    Yakushin, V.; Bel'kova, L.; Sevastyanova, I.

    2012-11-01

    The effect of hollow glass microspheres with a density of 125 kg/m3 on the properties of low-density (54-90 kg/m3) rigid polyurethane foams is investigated. The thermal expansion coefficient of the foams and their properties in tension and compression in relation to the content of the microspheres (0.5-5 wt.%) are determined. An increase in the characteristics of the material in compression in the foam rise direction with increasing content of filler is revealed. The limiting content of the microspheres above which the mechanical characteristics of the filled foams begin to decrease is found. The distribution of the microspheres in elements of the cellular structure of the polyurethane foams is examined.

  7. Structure-property relationships of flexible polyurethane foams

    Science.gov (United States)

    Aneja, Ashish

    This study examined several features of flexible polyurethane foams from a structure-property perspective. A major part of this dissertation addresses the issue of connectivity of the urea phase and its influence on mechanical and viscoelastic properties of flexible polyurethane foams and their plaque counterparts. Lithium salts (LiCl and LiBr) were used as additives to systematically alter the phase separation behavior, and hence the connectivity of the urea phase at different scale lengths. Macro connectivity, or the association of the large scale urea rich aggregates typically observed in flexible polyurethane foams was assessed using SAXS, TEM, and AFM. These techniques showed that including a lithium salt in the foam formulation suppressed the formation of the urea aggregates and thus led to a loss in the macro level connectivity of the urea phase. WAXS and FTIR were used to demonstrate that addition of LiCl or LiBr systematically disrupted the local ordering of the hard segments within the microdomains, i.e., it led to a reduction of micro level connectivity or the regularity in segmental packing of the urea phase. Based on these observations, the interaction of the lithium salt was thought to predominantly occur with the urea hard segments, and this hypothesis was confirmed using quantum mechanical calculations. Another feature of this research investigated model trisegmented polyurethanes based on monofunctional polyols, or "monos", with water-extended toluene diisocyanate (TDI) based hard segments. The formulations of the monol materials were maintained similar to those of flexible polyurethane foams with the exceptions that the conventional polyol was substituted by an oligomeric monofunctional polyether of ca. 1000 g/mol molecular weight. Plaques formed from these model systems were shown to be solid materials even at their relatively low molecular weights of 3000 g/mol and less, AFM phase images, for the first time, revealed the ability of the hard

  8. Gamma radiation effect on sisal / polyurethane composites without coupling agents

    Energy Technology Data Exchange (ETDEWEB)

    Vasco, Marina Cardoso; Claro Neto, Salvador; Nascimento, Eduardo Mauro; Azevedo, Elaine, E-mail: marina.mcv@gmail.com [University of Patras (Greece); Universidade de Sao Paulo (USP) Sao Carlos, SP (Brazil); Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil)

    2017-04-15

    Natural fibers and polyurethane based composites may present chemical bonding between the components of the polymer and the lignin of the fiber. The incidence of radiation can cause degradation of the polymeric material and alter its mechanical properties. The objective of this study was to obtain and characterize cold pressed composites from polyurethane derived from castor oil and sisal fibers, without coupling agents, through thermogravimetric and mechanical tests, before and after the incidence of 25 kGy dose of gamma radiation. Woven composites that were not irradiated had maximum values of 4.40 GPa for flexural elastic modulus on three point flexural test and dispersed fiber composite that were not irradiated had maximum values of 2.25 GPa. These materials are adequate for use in non-structural applications in radiotherapy and radiodiagnostic rooms. (author)

  9. The small angle neutron scattering study on the segmented polyurethane

    Energy Technology Data Exchange (ETDEWEB)

    Sudirman; Gunawan; Prasetyo, S.M.; Karo Karo, A.; Lahagu, I.M.; Darwinto, Tri [Materials Science Research Center, National Nuclear Energy Agency, Serpong, Tangerang (Indonesia)

    1999-10-01

    The distance between hard segment (HS) and soft segment (SS) of segmented polyurethane have been determined using the Small Angle Neutron Scattering (SANS) technique. The segmented Polyurethanes (SPU) are linear multiblock copolymers, which include elastomer thermoplastic. SPU consist of hard segment and soft segment, each has tendency to make a group with similar type to form a domain. The soft segments used were polypropylene glycol (PPG) and 4,4 diphenylmethane diisocyanate (MDI), while l,4 butanediol (BD) was used as hard segment. The characteristic of SPU depends on its phase structure which is affected by several factors, such as type of chemical formula and the composition of the HS and SS, solvent as well as the synthesizing process. The samples used in this study were SPU56 and SPU68. Based on the appearance of SANS profile, it was obtained that domain distances are 12.32 nm for the SPU56 and 19 nm for the SPU68. (author)

  10. Glycolysis recycling of rigid waste polyurethane foam from refrigerators.

    Science.gov (United States)

    Zhu, P; Cao, Z B; Chen, Y; Zhang, X J; Qian, G R; Chu, Y L; Zhou, M

    2014-01-01

    Rapid growth of rigid waste polyurethane (WPUR) foam from refrigerators attracts the attention all over the world. In this study, glycolysis was chosen to treat WPUR from scrapped refrigerators collected in Shanghai, China. Glycolysis reagents and catalysts were selected. The results indicated that the glycolysis efficiency of ethylene glycol (EG) was higher than that of diethylene glycol, and the catalytic efficiency of alkali metal salts (NaOH) was more excellent than that of triethanolamine and organic salts of alkali metal (NaAc). When EG was 100%WPUR as a glycolysis reagent and NaOH was 1%WPUR as a catalyst at a constant temperature of 197.85°C for 2 h, the glycolysis product had the highest glycolysis conversion rate. In order to maximize the recycling of WPUR, regenerative Polyurethane was performed by adding 10% distilled mixed polyol, which conformed to the QB/T 26689-2011 requirements.

  11. Performance of selected polyurethane joint sealants in concrete structures

    Directory of Open Access Journals (Sweden)

    Nečasová Barbora

    2018-01-01

    Full Text Available Often underestimated and neglected, joint sealants in concrete structures play an important role in protecting the structure against its premature deterioration. The focus of the presented paper lays upon the issue of sealing of joints in concrete structures. Concrete is one of the most difficult materials to seal since there are always small particles of dust and the material itself. In this paper, the joint will be viewed as traditional expansion joint. Two representatives of flexible one component polyurethane sealants were selected. The main reason for this selection was that conventional repair materials are usually very rigid and easily incline towards the formation of cracks and gaps. The aim of this paper is not only to verify the suitability of selected materials but also to demonstrate that polyurethane sealants might be a better and long-lasting solution for filling of joints and patching of cracks within concrete structures.

  12. Reperfusion hemorrhage following superior mesenteric artery stenting.

    LENUS (Irish Health Repository)

    Moore, Michael

    2012-02-03

    Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

  13. Papain Immobilized Polyurethane Film as Antimicrobial Food Package

    OpenAIRE

    M. Cynthya; V. Prabhawathi; D. Mukesh

    2014-01-01

    Food contamination occurs during post process handling. This leads to spoilage and growth of pathogenic microorganisms in the food, thereby reducing its shelf life or spreading of food borne diseases. Several methods are tried and one of which is use of antimicrobial packaging. Here, papain, a protease enzyme, is covalently immobilized with the help of glutarldehyde on polyurethane and used as a food wrap to protect food from microbial contamination. Covalent immobilizati...

  14. Glycolysis of flexible polyurethane foam in recycling of car seats

    Czech Academy of Sciences Publication Activity Database

    Beneš, Hynek; Rösner, J.; Holler, Petr; Synková, Hana; Kotek, Jiří; Horák, Zdeněk

    2007-01-01

    Roč. 18, č. 2 (2007), s. 149-156 ISSN 1042-7147. [International Conference on Polymeric Materials in Automotive , Slovak Rubber Conference /17./. Bratislava, 10.5.2005-12.5.2005] R&D Projects: GA MŽP SL/7/26/05 Institutional research plan: CEZ:AV0Z40500505 Keywords : polyurethanes * foams * recycling Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.504, year: 2007

  15. The effects of using immobilizer made of the polyurethane foam

    International Nuclear Information System (INIS)

    Kim, Yong Hwan; Chung, Sang Hwa; Kim, Hwa Young; Lim, Shin Taek; Oh, Sae Dong

    1992-01-01

    The immogilzer for control the patient movement during the radiation beam on was made of the polyurethane foam. The time consumption is abut 8 minutes for completely making the immobilizer. In this experimental study, the effects of using the individual immobilizer have shown that the patients have had always a same position with comfortable and high reproducibilities. Furthermore, it has shown the time for patient setup was decreased by using the individual patient immobilizer.

  16. Environmental Friendly Polyurethane Coatings Based On Hyperbranched Resin

    OpenAIRE

    Ashraf M. Elsaid; Magd M. Badr; Mohamed S. Selim

    2013-01-01

    Water borne polyurethane (PU) based on newly prepared hyperbranched poly (amine-ester) (HBPAE) was applied and evaluated as organic coating material. HBPAE was prepared through one-pot synthesis between trimethylol propane as a core and AB2 branched monomer which was obtained via Michal addition of methyl methacrylate (MMA) and diethanol amine (DEA). PU was prepared from HBPAE using different ratios of toluene diisocyanate (TDI) to form cured coating film. The prepared HBPAE was characterized...

  17. Preparation and characterization of polyurethane - Fe powder composites

    Czech Academy of Sciences Publication Activity Database

    Špírková, Milena; Bureš, R.; Fáberová, M.; Trchová, Miroslava; Strachota, Adam; Kaprálková, Ludmila

    2011-01-01

    Roč. 11, 3/4 (2011), s. 290-299 ISSN 1335-8987 R&D Projects: GA ČR GAP108/10/0195 Institutional research plan: CEZ:AV0Z40500505 Keywords : polyurethanes * polybutadiene diol * Fe powder Subject RIV: CD - Macromolecular Chemistry http://www.imr.saske.sk/pmp/issue/3-4-2011/PMP_Vol11_No3-4_p_290-299.pdf

  18. Dynamic mechanical and water sorption behaviour of ordered polyurethanes

    Czech Academy of Sciences Publication Activity Database

    Valentová, H.; Nedbal, J.; Ilavský, Michal; Pissis, P.

    307-310, - (2002), s. 304-310 ISSN 0022-3093 R&D Projects: GA ČR GA203/00/1314; GA ČR GA203/00/D114; GA AV ČR IAA4112901 Institutional research plan: CEZ:AV0Z4050913 Keywords : polyurethanes * mesogenic diol * polybutadiene Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.435, year: 2002

  19. Thermomechanical constitutive modeling of polyurethane-series shape memory polymer

    Energy Technology Data Exchange (ETDEWEB)

    Tobushi, H.; Ito, N.; Takata, K. [Aichi Inst. of Technol., Nagoya (Japan). Dept. of Mech. Eng.; Hayashi, S. [Nagoya Research and Development Center, Mitsubishi Heavy Industries, Ltd., Nagoya (Japan)

    2000-07-01

    In order to describe the thermomechanical properties in shape memory polymer of polyurethane series, a thermomechanical constitutive model was developed. In order to describe the variation in mechanical properties due to the glass transition, coefficients in the model were expressed by a single exponential function of temperature. The proposed theory expressed well the thermomechanical properties of the material, such as shape fixity and shape recovery. (orig.)

  20. Impact on outcome of different types of carotid stent: results from the European Registry of Carotid Artery Stenting.

    Science.gov (United States)

    Stabile, Eugenio; Giugliano, Giuseppe; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitrios; Sannino, Anna; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Rubino, Paolo; Esposito, Giovanni; Tesorio, Tullio

    2016-06-12

    Conflicting data exist on the impact on outcome of the use of different stent types during carotid artery stenting (CAS). The aim of this study was to evaluate clinical outcomes according to different carotid stent design among the population of the European Registry of Carotid Artery Stenting (ERCAS). The present study was conducted in 1,604 patients who underwent neuroprotected CAS in ERCAS. All types of commercially available carotid stent were used. Open-cell design stents were classified according to free cell area into 7.5 mm2. A total of 713 closed-cell, 456 hybrid-cell, 238 7.5 mm2 open-cell stents were implanted. Overall, the 30-day stroke and death rate was 1.37%. At 30 days, 19 strokes occurred (1.18%): eight in the group of patients treated with a closed-cell (1.12%), two in those with a hybrid-cell (0.44%), three in those with a 7.5 mm2 open-cell stent (3.05%) (p=0.045). Data of the present study suggest that, in the setting of neuroprotected CAS performed in high-volume centres by properly trained operators, the use of an open-cell design stent with a free cell area >7.5 mm2 may be associated with an increased 30-day stroke risk.

  1. Coated stents to prevent restenosis in coronary heart disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2005-11-01

    Full Text Available Background: In-stent-restenosis (ISR is considered to be an essential limiting factor of stenting in coronary heart disease (CHD. The development of coated stents has raised expectations on substantial lowering restenosis after stenting with decreasing the rate of restenosis and a reduction in the rate of clinical events. Objectives: The present analysis addresses the questions on medical effectiveness and cost-effectiveness of the use of various coated stent types in CHD. Methods: The literature was searched in December 2004 in the most relevant medical and economic databases. The medical evaluation was conducted on the basis of published RCT. The data from the studies regarding various angiographic, sonographic and clinical endpoints were checked for methodical quality and summarised in meta-analyses. Within the scope of economic evaluation the primary studies were analysed and modelling was performed, applying clinical effect estimates from the meta-analyses of the medical evaluation and current estimates of German costs. Results: Medical evaluation: Ten different stenttypes were used in the included 26 RCT. The results for heparin, silicon-carbide, carbon and PTFE coated stenttypes could not reveal any significant differences between the medical effectiveness of coated and uncoated stents. The application of sirolimus, paclitaxel, everolimus and 7-hexanoyltaxol eluting stents showed a significant lower restenosis at 6-9 months with decrease in the rate of restenosis for polymer-based sirolimus, paclitaxel and 7-hexanoyltaxol eluting stents. In contrast, the use of gold-coated and actinomycin-D eluting stents was associated with a significantly higher restenosis. The polymer-based sirolimus and paclitaxel eluting stents also showed a significant and considerable reduction in the rate of repeated percutaneous revascularisations at 6-12 months (3.5% vs. 19.7%; p<0.0001, RR=0.19 [95%CI: 0.11; 0.33] and 3.5% vs. 12.2%; p<0.0001, RR=0.30 [95%CI: 0

  2. Investigation of Stent Implant Mechanics Using Linear Analytical and Computational Approach.

    Science.gov (United States)

    Yang, Hua; Fortier, Aleksandra; Horne, Kyle; Mohammad, Atif; Banerjee, Subhash; Han, Hai-Chao

    2017-03-01

    Stent implants are essential in restoring normal blood flow in atherosclerotic arteries. Recent studies have shown high failure rates of stent implants in superficial femoral artery (SFA) as a result of dynamic loading environment imposed on the stent implants by the diseased arterial wall and turbulent blood flow. There are variety of stent designs and materials currently on the market however, there is no clear understanding if specific stent design is suitable with the material that is manufactured from and if this combination can sustain the life-cycle that the stent implants need to undergo once inside the artery. Lack of studies have been presented that relate stent mechanical properties with stent geometry and material used. This study presents linear theoretical and computational modeling approach that determines stent mechanical properties with effective stiffness of the deployed stent. Effective stiffness of the stent has been accurately derived based on stent structure design and loading in axial and radial directions. A rhombus stent structure was selected for this study due to its more common use and produced by main stream manufacturers. The derived theoretical model was validated using numerical finite element modeling approach. Results from this study can lead to preliminary insight towards understanding of stent deformation based on stent geometry, material properties and artery wall pressure; and how to carefully match stent's geometry with suitable material for long life cycle, increased strength, and reliable performance of stent implants.

  3. Stent selection in patients with myocardial infarction: drug eluting, biodegradable polymers or bare metal stents?

    Science.gov (United States)

    Mieres, Juan; Rodríguez, Alfredo E

    2012-08-01

    Percutaneous coronary intervention (PCI) has been increasingly used in the last years during interventional procedures in patients with acute coronary syndromes (ACS) including ST elevation myocardial infarction (STEMI) and non-ST elevation myocardial infarction (NSTEMI). In patients with either STEMI, NSTEMI, high risk ACS with EKG changes or cardiac enzymes rises; PCI with bare metal stent (BMS) implantation has been associated with a significant improvement in clinical outcome. Therefore, BMS implantation during primary PCI in STEMI has become a standard of practice. With the introduction of drug eluting stents (DESs) in this decade, the use of these new devices instead of BMSs in patients with STEMI has emerged as a rational PCI alternative in this particular subgroup of patients. In spite of the unquestionable benefits of DESs in terms of reduction of restenosis and TVR, specific concerns have arisen with regard to their long-term safety. High incidence of very late stent thrombosis has been described with these devices, and special attention should be paid in patients with unstable coronary lesions, in which plaque composition and remodeling may play a main role in their safety and long-term outcome. Intraluminal thrombus caused by plaque rupture is the most frequent mechanism of STEMI, in which the necrotic core and thin fibrous cap play a major role. In this context, the use of first DESs designs may be futile or even unsafe because delayed healing may further contribute to plaque instability. Adjunctive invasive imaging tools can improve stent deployment and safety outcome in these lesions with intravascular findings of plaque instability. Recently, other players such as new dedicated antithrombotic BMS designs, including selfexpanding stents or drug-eluting coated balloons, are exploring their potential indications in patients with ACS and myocardial infarction. This paper reports and discusses new stent devices and adjunctive pharmacologic agents. It

  4. Treatment of carotid artery aneurysms with covered stents; Aneurysmabehandlung der Arteria carotis interna mit gecoverten Stents

    Energy Technology Data Exchange (ETDEWEB)

    Rohr, A.; Alfke, K.; Doerner, L.; Jansen, O. [UKSH Kiel (Germany). Neurochirurgie Neuroradiologie; Bartsch, T.; Stingele, R. [UKSH Kiel (Germany). Neurologie

    2007-10-15

    Purpose: Evaluation of the use of covered stents in treating pseudoaneurysms of the cervical and intracranial/extradural carotid artery and determination of the periprocedural and short- to mid-term complication rate. Materials and Methods: 8 patients with 9 spontaneous dissecting aneurysms of the cervical carotid artery - 5 of which were symptomatic - plus one patient with ofthalmoplegia due to an aneurysm of the cavernous carotid artery were studied. While the latter was treated with a PTFE-covered balloon-mounted stainless steel stent (Jostent/Graftmaster), a self-expanding PTFE-covered Nitonol Stent (Symbiot) was used in all other cases. Intervention was performed with local anesthesia. Aspirin and Clopidogrel were both used as antiplatelet drugs. Clinical signs and symptoms and vascular imaging with DS, MR, CT angiography and ultrasound were recorded during patient follow-up, with a mean follow-up period of 14.6 months (4 - 30). Results: We were able to treat 8 out of 10 aneurysms (80 %) using covered stents. The aneurysms were immediately occluded and the associated stenoses of the parent vessel were eliminated. No clinically relevant complications occurred during the procedure or in the follow-up interval. In two cases, elongation of the carotid artery prevented the stent from being positioned over the aneurysm neck. These cases were shown to be stable with the use of antiplatelet drugs. Conclusion: Covered stents can be used in the treatment of pseudoaneurysms of the carotid artery as an alternative to long-term antithrombotic medication or surgery. In our study treatment was effective (80 %) and free of complications in the short- and mid-term follow-up. Possible indications, technique and the use of imaging modalities for patient follow-up are discussed. (orig.)

  5. Triggerable Degradation of Polyurethanes for Tissue Engineering Applications.

    Science.gov (United States)

    Xu, Cancan; Huang, Yihui; Wu, Jinglei; Tang, Liping; Hong, Yi

    2015-09-16

    Tissue engineered and bioactive scaffolds with different degradation rates are required for the regeneration of diverse tissues/organs. To optimize tissue regeneration in different tissues, it is desirable that the degradation rate of scaffolds can be manipulated to comply with various stages of tissue regeneration. Unfortunately, the degradation of most degradable polymers relies solely on passive controlled degradation mechanisms. To overcome this challenge, we report a new family of reduction-sensitive biodegradable elastomeric polyurethanes containing various amounts of disulfide bonds (PU-SS), in which degradation can be initiated and accelerated with the supplement of a biological product: antioxidant-glutathione (GSH). The polyurethanes can be processed into films and electrospun fibrous scaffolds. Synthesized materials exhibited robust mechanical properties and high elasticity. Accelerated degradation of the materials was observed in the presence of GSH, and the rate of such degradation depends on the amount of disulfide present in the polymer backbone. The polymers and their degradation products exhibited no apparent cell toxicity while the electrospun scaffolds supported fibroblast growth in vitro. The in vivo subcutaneous implantation model showed that the polymers prompt minimal inflammatory responses, and as anticipated, the polymer with the higher disulfide bond amount had faster degradation in vivo. This new family of polyurethanes offers tremendous potential for directed scaffold degradation to promote maximal tissue regeneration.

  6. Chemical and Enzymatic Hydrolysis of Polyurethane/Polylactide Blends

    Directory of Open Access Journals (Sweden)

    Joanna Brzeska

    2015-01-01

    Full Text Available Polyether-esterurethanes containing synthetic poly[(R,S-3-hydroxybutyrate] (R,S-PHB and polyoxytetramethylenediol in soft segments and polyesterurethanes with poly(ε-caprolactone and poly[(R,S-3-hydroxybutyrate] were blended with poly([D,L]-lactide (PLA. The products were tested in terms of their oil and water absorption. Oil sorption tests of polyether-esterurethane revealed their higher response in comparison to polyesterurethanes. Blending of polyether-esterurethanes with PLA caused the increase of oil sorption. The highest water sorption was observed for blends of polyether-esterurethane, obtained with 10% of R,S-PHB in soft segments. The samples mass of polyurethanes and their blends were almost not changed after incubation in phosphate buffer and trypsin and lipase solutions. Nevertheless the molecular weight of polymers was significantly reduced after degradation. It was especially visible in case of incubation of samples in phosphate buffer what suggested the chemical hydrolysis of polymer chains. The changes of surface of polyurethanes and their blends, after incubation in both enzymatic solutions, indicated on enzymatic degradation, which had been started despite the lack of mass lost. Polyurethanes and their blends, contained more R,S-PHB in soft segments, were degraded faster.

  7. Cellulose based hybrid hydroxylated adducts for polyurethane foams

    Science.gov (United States)

    De Pisapia, Laura; Verdolotti, Letizia; Di Mauro, Eduardo; Di Maio, Ernesto; Lavorgna, Marino; Iannace, Salvatore

    2012-07-01

    Hybrid flexible polyurethane foams (HPU) were synthesized by using a hybrid hydroxilated adduct (HHA) based on renewable resources. In particular the HHA was obtained by dispersing cellulose wastes in colloidal silica at room temperature, pressure and humidity. The colloidal silica was selected for its ability of modifying the cellulose structure, by inducing a certain "destructurization" of the crystalline phase, in order to allow cellulose to react with di-isocyanate for the final synthesis of the polyurethane foam. In fact, cellulose-polysilicate complexes are engaged in the reaction with the isocyanate groups. This study provides evidence of the effects of the colloidal silica on the cellulose structure, namely, a reduction of the microfiber cellulose diameter and the formation of hydrogen bonds between the polysilicate functional groups and the hydroxyl groups of the cellulose, as assessed by IR spectroscopy and solid state NMR. The HHA was added to a conventional polyol in different percentages (between 5 and 20%) to synthesize HPU in presence of catalysts, silicone surfactant and diphenylmethane diisocyanate (MDI). The mixture was expanded in a mold and cured for two hours at room temperature. Thermal analysis, optical microscopy and mechanical tests were performed on the foams. The results highlighted an improvement of thermal stability and a decrease of the cell size with respect neat polyurethane foam. Mechanical tests showed an improvement of the elastic modulus and of the damping properties with increasing HHA amount.

  8. Green waste cooking oil-based rigid polyurethane foam

    Science.gov (United States)

    Enderus, N. F.; Tahir, S. M.

    2017-11-01

    Polyurethane is a versatile polymer traditionally prepared using petroleum-based raw material. Petroleum, however, is a non-renewable material and polyurethane produced was found to be non-biodegradable. In quest for a more environmentally friendly alternative, wastecooking oil, a highly abundant domestic waste with easily derivatized structure, is a viable candidate to replace petroleum. In this study,an investigation to determine physical and chemical properties of rigid polyurethane (PU) foam from waste cooking oil (WCO) was carried out. WCO was first adsorbed by using coconut husk activated carbon adsorbent prior to be used for polyol synthesis. The purified WCO was then used to synthesize polyol via transesterification reaction to yield alcohol groups in the WCO chains structure. Finally, the WCO-based polyol was used to prepare rigid PU foam. The optimum formulation for PU formation was found to be 90 polyol: 60 glycerol: 54 water: 40 diethanolamine: 23 diisocyanate. The rigid PU foam has density of 208.4 kg/m3 with maximum compressive strength and capability to receive load at 0.03 MPa and 0.09 kN, respectively. WCO-based PU can potentially be used to replace petroleum-based PU as house construction materials such as insulation panels.

  9. A multilayered polyurethane foam technique for skin graft immobilization.

    Science.gov (United States)

    Nakamura, Motoki; Ito, Erika; Kato, Hiroshi; Watanabe, Shoichi; Morita, Akimichi

    2012-02-01

    Several techniques are applicable for skin graft immobilization. Although the sponge dressing is a popular technique, pressure failure near the center of the graft is a weakness of the technique that can result in engraftment failure. To evaluate the efficacy of a new skin graft immobilization technique using multilayered polyurethane foam in vivo and in vitro. Twenty-six patients underwent a full-thickness skin graft. Multiple layers of a hydrocellular polyurethane foam dressing were used for skin graft immobilization. In addition, we created an in vitro skin graft model that allowed us to estimate immobilization pressure at the center and edges of skin grafts of various sizes. Overall mean graft survival was 88.9%. In the head and neck region (19 patients), mean graft survival was 93.6%. Based on the in vitro outcomes, this technique supplies effective pressure (polyurethane foam dressing is simple, safe, and effective for skin graft immobilization. © 2011 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  10. (Biodegradable Ionomeric Polyurethanes Based on Xanthan: Synthesis, Properties, and Structure

    Directory of Open Access Journals (Sweden)

    T. V. Travinskaya

    2017-01-01

    Full Text Available New (biodegradable environmentally friendly film-forming ionomeric polyurethanes (IPU based on renewable biotechnological polysaccharide xanthan (Xa have been obtained. The influence of the component composition on the colloidal-chemical and physic-mechanical properties of IPU/Xa and based films, as well as the change of their properties under the influence of environmental factors, have been studied. The results of IR-, PMS-, DMA-, and X-ray scattering study indicate that incorporation of Xa into the polyurethane chain initiates the formation of a new polymer structure different from the structure of the pure IPU (matrix: an amorphous polymer-polymer microdomain has occurred as a result of the chemical interaction of Xa and IPU. It predetermines the degradation of the IPU/Xa films as a whole, unlike the mixed polymer systems, and plays a key role in the improvement of material performance. The results of acid, alkaline hydrolysis, and incubation into the soil indicate the increase of the intensity of degradation processes occurring in the IPU/Xa in comparison with the pure IPU. It has been shown that the introduction of Xa not only imparts the biodegradability property to polyurethane, but also improves the mechanical properties.

  11. Vegetable Oil-Based Hyperbranched Thermosetting Polyurethane/Clay Nanocomposites

    Directory of Open Access Journals (Sweden)

    Deka Harekrishna

    2009-01-01

    Full Text Available Abstract The highly branched polyurethanes and vegetable oil-based polymer nanocomposites have been showing fruitful advantages across a spectrum of potential field of applications.Mesua ferreaL. seed oil-based hyperbranched polyurethane (HBPU/clay nanocomposites were prepared at different dose levels by in situ polymerization technique. The performances of epoxy-cured thermosetting nanocomposites are reported for the first time. The partially exfoliated structure of clay layers was confirmed by XRD and TEM. FTIR spectra indicate the presence of H bonding between nanoclay and the polymer matrix. The present investigation outlines the significant improvement of tensile strength, scratch hardness, thermostability, water vapor permeability, and adhesive strength without much influencing impact resistance, bending, and elongation at break of the nanocomposites compared to pristine HBPU thermoset. An increment of two times the tensile strength, 6 °C of melting point, and 111 °C of thermo-stability were achieved by the formation of nanocomposites. An excellent shape recovery of about 96–99% was observed for the nanocomposites. Thus, the formation of partially exfoliated clay/vegetable oil-based hyperbranched polyurethane nanocomposites significantly improved the performance.

  12. Sellado de aneurisma coronario con stent cubierto de PTFE (stent graft)

    OpenAIRE

    Portero Pérez,Ma Pilar; Ortas Nadal,Ma Rosario; Ruiz Arroyo,José Ramón; Escota Villanueva,Javier; Peleato Peleato,Antonio

    2008-01-01

    Los aneurismas coronarios son muy raros, su frecuencia oscila entre el 1 y el 2%, siendo la aterosclerosis la enfermedad más asociada, aunque se han descrito los de origen congénito, los asociados a la enfermedad de Kawasaki, a enfermedades del tejido conectivo, a enfermedades infecciosas y a traumatismos torácicos. También se observan los relacionados con la implantación del stent, con la braquiterapia intracoronaria y con los "stents" recubiertos de fármacos. Su evolución no es muy bien con...

  13. Stent placement of gastroenteric anastomoses formed by magnetic compression.

    Science.gov (United States)

    Cope, C; Clark, T W; Ginsberg, G; Habecker, P

    1999-01-01

    To evaluate the use of stents for prolonging the patency of gastroenteric anastomoses (GEA) induced by magnet compression. Rare earth magnets were inserted perorally and serially in 15 dogs so as to mate across the gastric and jejunal walls. After magnet excretion, the resulting GEA was identified endoscopically, dilated (n = 1), and stented with bare (n = 2) or partially covered (n = 6) flared 10-mm or 12-mm Z stents. The GEA was followed at 2-4-week intervals for patency; malfunctioning shunts were irrigated, or dilated with angioplasty balloons. Gross and histologic examination of the anastomotic tissues was performed in 14 animals. Magnet pairs were excreted in 5-7 days. Of the 19 magnet placements in 15 animals, stent placement was not possible because of early GEA closure (n = 6), failure to locate (n = 2), pancreatic abscess (n = 1), and magnet perforation with peritonitis (n = 1). Estimated duration of GEA patency was 19 days after balloon dilation, 40-64 days with bare Z stents, and 58-147 days (mean, 90 days) with partially covered Z stents. Shunt function was commonly hindered by bezoars. Stent narrowing or occlusion was caused by tissue overgrowth through bare stents (n = 2), between covered stent struts and through partially detached membrane (n = 2). Serious morbidity (n = 2) was due to malpositioned magnets across the pancreas in one animal and gastric perforation in the other. One dog was euthanized because of unsuspected kidney infection. Partially covered stents significantly extend the anatomic patency rate of magnetic GEA to 7 weeks or more. Functional patency is frequently impaired by bezoars. Ongoing improvements in covered stent design should provide longer-term GEA patency.

  14. Chest pain following oesophageal stenting for malignant dysphagia

    International Nuclear Information System (INIS)

    Golder, Mark; Tekkis, Paris P.; Kennedy, Colette; Lath, Sadaf; Toye, Rosemary; Steger, Adrian C.

    2001-01-01

    AIM: The palliative use of self-expanding metallic stents has been widely reported to relieve dysphagia in cases of oesophageal carcinoma. Little has been documented on the severity of chest pain following oesophageal stenting. The aim of this study was to investigate the association of pain with oesophageal stenting for malignant dysphagia. METHODS: Fifty-two patients with inoperable oesophageal carcinoma underwent stent placement between 1995-1999. Daily opioid analgesic requirements (mg of morphine equivalent doses) were monitored for 3 days before and 7 days after stenting. The degree of palliation was expressed as a dysphagia score (0-3). Hospital stay, readmission days, stent complications and patient survival time were also recorded. RESULTS: Twenty-six patients (50%) required opioid analgesia for chest pain (median dose: 80 mg morphine/day) within 48 h of the procedure compared to 11 (21.2%) patients before stenting (P = 0.0041). A significant increase was evident in the analgesic consumption following stent deployment (P < 0.001). The dysphagia score improved by a median value of 1 (CI 0.25)P < 0.001, with a re-intervention rate of 11.5%. The median survival time was 40 days post stenting (range 1-120). CONCLUSION: A significant proportion of patients developed chest pain after oesophageal stenting, requiring high dose opioid analgesia. As the origin of the pain is still unknown, pre-emptive analgesia may a play role in reducing stent-related morbidity and possibly in-hospital stay. Golder, M. et al. (2001)

  15. [Biodegradable catheters and urinary stents. When?

    Science.gov (United States)

    Soria, F; Morcillo, E; López de Alda, A; Pastor, T; Sánchez-Margallo, F M

    2016-10-01

    One of the main wishes in the field of urinary catheters and stents is to arm them with biodegradable characteristics because we consider a failure of these devices the need for retrieval, the forgotten catheter syndrome as well as the adverse effects permanent devices cause after fulfilling their aim. The efforts focused in new designs, coatings and biomaterials aim to increase the biocompatibility of theses internal devices. Lately, there have been correct advances to answer the main challenges regarding biodegradable ureteral devices. Thus, modulation of the rate of degradation has been achieved thanks to new biomaterials and the use of copolymers that enable to choose the time of permanence as it is programmed with conventional double J catheters. Biocompatibility has improved with the use of new polymers that adapt better to the urine. Finally, one of the main problems is elimination of degraded fragments and experimentally it has be demonstrated that new designs elicit controlled degradation, from distal to proximal; using stranding and combination of copolymers degradation may be caused by dilution, reducing fragmentation to the last stages of life of the prosthesis. Moreover, it has been demonstrated that biodegradable catheters potentially may cause less urinary tract infection, less encrustation and predictably they will diminish catheter morbidity, since their degradation process reduces adverse effects. Regarding the development of biodegradable urethral stents, it is necessary to find biomaterials that enable maintaining their biomechanical properties in the long term, keeping open the urethral lumen both in patients with BPH and urethral stenosis. Modulation of the time of degradation of the prosthesis has been achieved, but the appearance of urothelial hyperplasia is still a constant in the initial phases after implantation. The development of drug eluting stents, anti-proliferative or anti-inflammatory, as well as biodegradable stents biocoated is a

  16. A Multicenter Randomized Controlled Trial of Malignant Gastric Outlet Obstruction: Tailored Partially Covered Stents (Placed Fluoroscopically versus Standard Uncovered Stents (Placed Endoscopically

    Directory of Open Access Journals (Sweden)

    Ding Shi

    2014-01-01

    Full Text Available The aim of our study is to compare the efficacy and safety of “outlet-shape” tailored stents with standard stents for the management of distal gastric cancer causing gastric outlet obstructions (GOOs with varying gastric cavity shapes and sizes. To determine the shape and size of the GOOs, stomach opacifications were performed using contrast media before stenting. Two basic shapes of the residual cavity of the proximal GOO were observed: cup shaped or approximately cup shaped and funnel shaped or approximately funnel shaped. Other shapes were not found. In the GOO tailored group, the size and shape of the proximal ends of the tailored stent were suited for the residual cavity of the proximal GOO. The tailored stents included large cup-shaped stents and large funnel-shaped stents. GOO tailored covered stents led to less restenosis and reintervention rates compared to standard uncovered stents but with the same survival.

  17. Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs.

    Science.gov (United States)

    Holzapfel, Gerhard A; Stadler, Michael; Gasser, Thomas C

    2005-02-01

    Clinical studies have identified factors such as the stent design and the deployment technique that are one cause for the success or failure of angioplasty treatments. In addition, the success rate may also depend on the stenosis type. Hence, for a particular stenotic artery, the optimal intervention can only be identified by studying the influence of factors such as stent type, strut thickness, geometry of the stent cell, and stent-artery radial mismatch with the wall. We propose a methodology that allows a set of stent parameters to be varied, with the aim of evaluating the difference in the mechanical environment within the wall before and after angioplasty with stenting. Novel scalar quantities attempt to characterize the wall changes inform of the contact pressure caused by the stent struts, and the stresses within the individual components of the wall caused by the stent. These quantities are derived numerically and serve as indicators, which allow the determination of the correct size and type of the stent for each individual stenosis. In addition, the luminal change due to angioplasty may be computed as well. The methodology is demonstrated by using a full three-dimensional geometrical model of a postmortem specimen of a human iliac artery with a stenosis using imaging data. To describe the material behavior of the artery, we considered mechanical data of eight different vascular tissues, which formed the stenosis. The constitutive models for the tissue components capture the typical anisotropic, nonlinear and dissipative characteristics under supra-physiological loading conditions. Three-dimensional stent models were parametrized in such a way as to enable new designs to be generated simply with regard to variations in their geometric structure. For the three-dimensional stent-artery interaction we use a contact algorithm based on smooth contact surfaces of at least C-continuity, which prevents numerical problems known from standard facet-based contact

  18. Changing the double-pigtail stent by a new suture stent to improve patient's quality of life: a prospective study.

    Science.gov (United States)

    Vogt, Benoît; Desgrippes, Arnaud; Desfemmes, François-Noël

    2015-08-01

    Double-pigtail stent intolerance reduces patient's quality of life. By decreasing the amount of material within the bladder, it should be possible to attenuate stent's symptoms. We evaluated the tolerance of a new stent with a dedicated questionnaire. The major innovation of the pigtail suture stent (PSS) is in the replacement of the lower part of the double-pigtail stent with a 0.3F suture. A total of 79 consecutive patients agreed to be fitted with a PSS. The double-pigtail stents of 24 patients complaining strongly of symptoms were replaced with PSS (group 1), and 55 other patients were fitted directly with the PSS after an ureteral endoscopic intervention (group 2). The questionnaire was prospectively administered to patients at baseline and Day 15 post-placement. All questionnaires were returned. In group 1, the replacement of the double-pigtail stent with a PSS significantly decreased urinary symptom scores (35.2 ± 7.5 vs. 23.6 ± 5.4; p = 2 × 10(-6)) and pain scores (11.0 ± 3.9 vs. 4.9 ± 3.1; p = 1 × 10(-7)). In group 1, the baseline scores were not significantly different from those of control group with double-pigtail stent. In group 2, the urinary scores with PSS were significantly different from those of baseline without stent. The scores of the two groups fitted with a PSS were not significantly different at Day 15 post-placement. Unexpectedly, following PSS implantation, we observe a clear dilation of the ureter without inflammation around the suture. The PSS significantly decreases stent's symptoms and constitutes a medical advance in the domain of ureteral stent tolerance.

  19. An unusual late complication after SFA stenting: the artery rupture.

    Science.gov (United States)

    Chisci, E; De Donato, G; Setacci, F; Raucci, A; Giubbolini, M; Setacci, C

    2009-04-01

    Peripheral artery rupture as a late complication of an endovascular stenting, due to the protrusion of a stent, has never been described in the literature in thigh arteries. Here we describe two anecdotic cases of artery rupture after superficial femoral artery (SFA) stenting. In both cases the endovascular procedure was performed as a reintervention at 2 and 27 months after a failed surgical or hybrid procedure for limb revascularization. The stent had been delivered in the first part of the SFA and the rupture occurred at the junction between the common femoral artery and SFA, which is one of the most flexible parts of the femoral artery. The cause of rupture was probably caused by an ulcer of the stent against the artery wall concomitant with a status of local or systemic infection. A huge pseudoaneurysm developed in both cases. The massive bleeding was stopped by an emergency surgical bypass, with the removal of the stented artery. These two cases show the possibility of SFA rupture after stenting. Previous surgical treatment, the site of stenting (first part of the SFA) and an active infection could predispose patients to this life-threatening complication.

  20. An experimental study of inferior vena caval stent in canine.

    Science.gov (United States)

    Zhang, X; Wang, Z; Guo, J

    1999-09-01

    To investigate the feasibility of our self made inferior vena cave (IVC) stent. Self-expanding, stainless steel, Z-shaped stents were deployed in the IVC of 14 dogs. They were randomly divided into four groups, four dogs in the first three groups, and 2 in the fourth group. IVC specimens were taken at 2, 4, 8 and 16 weeks following stent deployment. No anticoagulant or antiplatelet therapy was given. All stents were widely stretched out and so was the vessel lumen. No thrombus was present and the patency was 100% in all groups. The stents were completely covered by neointima 2 weeks after stent deployment. The neointimal thickness varied significantly: the thinnest at 2 weeks, the thickest at 4 weeks and becoming thinner at 8 weeks and stable until 16 weeks. The inflammatory reaction was gradually reduced. Under scanning electronic microscopy, the neointima was covered by a layer of endothelial cells 2 weeks following stenting, which were irregularly shaped and aligned. The cells became slender, spindle-shaped and aligned parallel to the direction of bolld flow 4 weeks afterwards. Experimental study indicated that our self-expanding IVC stent was feasible for clinical application.

  1. Stented Vessels: A Challenge for Histological Preparation and Microscopy

    Directory of Open Access Journals (Sweden)

    Andrea Nolte

    2013-06-01

    Full Text Available Objective: The first procedure to treat blocked coronary arteries was coronary artery bypass graft surgery. In 1977, Andreas Gruntzig introduced percutaneous transluminal coronary angioplasty (PTCA. Today, several stent systems exist ranging from bare metal stents to various drug-eluting stents. Unfortunately, our understanding of the arterial reaction to stent implantation is incomplete – primarily due to technical limitations in the histological study of stented vascular tissue. Methods: In our study, we examined different histological preparation methods based on the embedding material methacrylate. The procedure of embedding and sectioning stented porcine arteries was optimized for the specific requirements, like histochemistry, immunohistochemistry or pre-stained fluorescence. Furthermore, we used a microscopical technique described as fluorescence intensity decay shape analysis microscopy (FIDSAM to eliminate auto-fluorescence from fluorescently labeled tissue. Results: The sections were suitable for histochemical and immunohistochemical staining. Additionally, pre-labeled fluorescence in the porcine tissue was not lost by the embedding process. The evaluation of arterial cross sections with FIDSAM technology gave new, very important insights into the examination possibilities of fluorescently labeled tissue. Conclusions: Future studies of the vascular response to a variety of new stent materials will provide important clues to the pathogenesis resulting in restenosis and occlusion of stents. [J Interdiscipl Histopathol 2013; 1(3.000: 104-112

  2. Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities

    Directory of Open Access Journals (Sweden)

    Maryam Moravej

    2011-06-01

    Full Text Available During the last decade, biodegradable metallic stents have been developed and investigated as alternatives for the currently-used permanent cardiovascular stents. Degradable metallic materials could potentially replace corrosion-resistant metals currently used for stent application as it has been shown that the role of stenting is temporary and limited to a period of 6–12 months after implantation during which arterial remodeling and healing occur. Although corrosion is generally considered as a failure in metallurgy, the corrodibility of certain metals can be an advantage for their application as degradable implants. The candidate materials for such application should have mechanical properties ideally close to those of 316L stainless steel which is the gold standard material for stent application in order to provide mechanical support to diseased arteries. Non-toxicity of the metal itself and its degradation products is another requirement as the material is absorbed by blood and cells. Based on the mentioned requirements, iron-based and magnesium-based alloys have been the investigated candidates for biodegradable stents. This article reviews the recent developments in the design and evaluation of metallic materials for biodegradable stents. It also introduces the new metallurgical processes which could be applied for the production of metallic biodegradable stents and their effect on the properties of the produced metals.

  3. Infant feeding tube as urinary tract stent | Ekeke | Port Harcourt ...

    African Journals Online (AJOL)

    Methods: Data from the hospital records of patients who required stents at the University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria were obtained from their case notes from May 2003 to May 2006. Information extracted from these case notes included: age and sex of patient, indications for stenting, ...

  4. Transhepatic approach for extracardiac inferior cavopulmonary connection stent fenestration.

    LENUS (Irish Health Repository)

    Kenny, Damien

    2012-02-01

    We report on a 3-year-old male who underwent transcatheter stent fenestration of the inferior portion of an extracardiac total cavopulmonary connection in the setting of hypoplastic left heart syndrome. Transhepatic approach, following an unsuccessful attempt from the femoral vein facilitated delivery of a diabolo-shaped stent.

  5. Retrograde superior mesenteric artery stenting for acute mesenteric arterial thrombosis.

    Science.gov (United States)

    Do, Natalie; Wisniewski, Paul; Sarmiento, Jose; Vo, Trung; Aka, Paul K; Hsu, Jeffrey H; Tayyarah, Majid

    2010-08-01

    Retrograde superior mesenteric artery stenting (ROMS) represents a significant development in the treatment of acute mesenteric ischemia. Compared to traditional surgical mesenteric bypass, ROMS is a less invasive technique that avoids many complications associated with emergent mesenteric bypass. This case report illustrates that retrograde superior mesenteric artery (SMA) stenting is an option for the treatment of acute mesenteric ischemia for patients in extremis.

  6. Intervention of malignant biliary obstruction with Hanaro spiral stent

    International Nuclear Information System (INIS)

    Shin, Sung Wook; Choo, Sung Wook; Pyeun, Yong Seon and others

    1999-01-01

    To evaluate the long-term patency of the Hanaro spiral stent (Solco Intermed, Seoul, Korea) when used as a palliative in patients with inoperable malignant biliary obstruction. Between April 1996 and July 1998, 39 patients with malignant biliary obstruction underwent percutaneous placement of 48 Hanaro spiral stents. The causes of obstruction were bile duct carcinoma (n=18), pancreatic carcinoma (n=8), metastatic lymphadenopathy (n=5), gallbladder carcinoma (n=5), hepatocellular carcinoma (n=1) and other tumors (n=2). Using the kaplan-Meier method, patient survival and stet patency rates were estimated with regard to level of obstruction. As regards stent insertion, there was no technical failure. Overall 25- and 50-week survival rates for the entire patient group were 50 % and 11 %, respectively, while overall stent patency rates at 25 and 50 weeks were 42 % and 11 %, respectively. Twenty-five-week stent patency rates in patients with common bile duct (CBD) and hilar obstruction were 51 % and 18 %, respectively. The stent patency rates in the CBD obstruction group was significantly higher than that in the hilar obstruction group (p<0.05). In patients with CBD obstruction, the clinical efficacy of Hanaro spiral stent was superior to that in patients with hilar obstruction. However, Hanaro spiral stents showed a lower patency rate with regard to patient survival, and further investigation is required

  7. Coronary bifurcation lesions treated with simple or complex stenting

    DEFF Research Database (Denmark)

    Behan, Miles W; Holm, Niels R; de Belder, Adam J

    2016-01-01

    AIMS: Randomized trials of coronary bifurcation stenting have shown better outcomes from a simple (provisional) strategy rather than a complex (planned two-stent) strategy in terms of short-term efficacy and safety. Here, we report the 5-year all-cause mortality based on pooled patient-level data...

  8. 40 CFR 63.1299 - Standards for slabstock flexible polyurethane foam production-source-wide emission limitation.

    Science.gov (United States)

    2010-07-01

    ... polyurethane foam production-source-wide emission limitation. 63.1299 Section 63.1299 Protection of Environment... Flexible Polyurethane Foam Production § 63.1299 Standards for slabstock flexible polyurethane foam... of foam grades produced in the month on foam production line j. limiti = HAP ABA formulation limit...

  9. 40 CFR 63.1296 - Standards for slabstock flexible polyurethane foam production-HAP ABA equipment leaks.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Standards for slabstock flexible polyurethane foam production-HAP ABA equipment leaks. 63.1296 Section 63.1296 Protection of Environment... Flexible Polyurethane Foam Production § 63.1296 Standards for slabstock flexible polyurethane foam...

  10. 40 CFR 63.1295 - Standards for slabstock flexible polyurethane foam production-HAP ABA storage vessels.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Standards for slabstock flexible polyurethane foam production-HAP ABA storage vessels. 63.1295 Section 63.1295 Protection of Environment... Flexible Polyurethane Foam Production § 63.1295 Standards for slabstock flexible polyurethane foam...

  11. 40 CFR 63.1298 - Standards for slabstock flexible polyurethane foam production-HAP emissions from equipment cleaning.

    Science.gov (United States)

    2010-07-01

    ... polyurethane foam production-HAP emissions from equipment cleaning. 63.1298 Section 63.1298 Protection of... Pollutants for Flexible Polyurethane Foam Production § 63.1298 Standards for slabstock flexible polyurethane foam production—HAP emissions from equipment cleaning. Each owner or operator of a new or existing...

  12. An assessment on modified AZ80 alloys for prospect biodegradable CV stent applications

    NARCIS (Netherlands)

    Erinc, M.; Sillekens, W.H.

    2009-01-01

    In medicine, stents are inserted into an artery to prevent local constrictions to blood flow. Commonly used stents are permanent metal stents, yet developments in this area are more and more heading towards biodegradable stents. Implants made of materials that can dissolve in the patient's body by

  13. Polymeric photosensitizer-embedded self-expanding metal stent for repeatable endoscopic photodynamic therapy of cholangiocarcinoma.

    Science.gov (United States)

    Bae, Byoung-chan; Yang, Su-Geun; Jeong, Seok; Lee, Don Haeng; Na, Kun; Kim, Joon Mee; Costamagna, Guido; Kozarek, Richard A; Isayama, Hiroyuki; Deviere, Jacques; Seo, Dong Wan; Nageshwar Reddy, D

    2014-10-01

    Photodynamic therapy (PDT) is a new therapeutic approach for the palliative treatment of malignant bile duct obstruction. In this study, we designed photosensitizer-embedded self-expanding nonvascular metal stent (PDT-stent) which allows repeatable photodynamic treatment of cholangiocarcinoma without systemic injection of photosensitizer. Polymeric photosensitizer (pullulan acetate-conjugated pheophorbide A; PPA) was incorporated in self-expanding nonvascular metal stent. Residence of PPA in the stent was estimated in buffer solution and subcutaneous implantation on mouse. Photodynamic activity of PDT-stent was evaluated through laserexposure on stent-layered tumor cell lines, HCT-116 tumor-xenograft mouse models and endoscopic intervention of PDT-stent on bile duct of mini pigs. Photo-fluorescence imaging of the PDT-stent demonstrated homogeneous embedding of polymeric Pheo-A (PPA) on stent membrane. PDT-stent sustained its photodynamic activities at least for 2 month. And which implies repeatable endoscopic PDT is possible after stent emplacement. The PDT-stent after light exposure successfully generated cytotoxic singlet oxygen in the surrounding tissues, inducing apoptotic degradation of tumor cells and regression of xenograft tumors on mouse models. Endoscopic biliary in-stent photodynamic treatments on minipigs also suggested the potential efficacy of PDT-stent on cholangiocarcinoma. In vivo and in vitro studies revealed our PDT-stent, allows repeatable endoscopic biliary PDT, has the potential for the combination therapy (stent plus PDT) of cholangiocarcinoma. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. “Bilateral Double J Stent Removal: The way to do it!”

    African Journals Online (AJOL)

    “Bilateral Double J Stent Removal: The way to do it!” Rahul Yadav, Divakar Dalela, Neeraj K. Goyal, Deepak ... It was ensured by imaging studies (X-ray and. USG KUB) in all patients, prior to DJ stent removal that ... stent and logically, saves operating time. REFERENCES. 1. Auge BK, Preminger GM. Ureteral stents and ...

  15. Anastomotic leak after oesophagectomy and stent implantation: a systematic review

    Directory of Open Access Journals (Sweden)

    A.N. Kanatas

    2011-12-01

    Full Text Available Anastomotic leaks following oesophageal cancer resection have a high mortality. Stents have an established position in the palliation of dysphagia due to malignancy and in treating malignant perforation or fistula. They are increasingly used for benign conditions such as spontaneous oesophageal perforation with encouraging results. In this systematic review we examine the available evidence and attempt to define the role of stents in the management of oesophageal anastomotic leaks after resection for cancer. It is evident from the review that plastic- and metal-covered stents are an effective strategy for the treatment of anastomotic leaks. Vigilance is required as complications such as stent migration and incomplete sealing are not uncommon. Further clinical studies with greater methodological rigor in terms of sample size and study design may confirm that stents have an important contribution to make in the management of oesophageal anastomotic leak.

  16. Electrospun Polyurethane Fibers for Absorption of Volatile Organic Compounds from Air

    NARCIS (Netherlands)

    Scholten, E.; Bromberg, L.; Rutledge, G.C.; Hatton, T.A.

    2011-01-01

    Electrospun polyurethane fibers for removal of volatile organic compounds (VOC) from air with rapid VOC absorption and desorption have been developed. Polyurethanes based on 4,4-methylenebis(phenylisocyanate) (MDI) and aliphatic isophorone diisocyanate as the hard segments and butanediol and

  17. The use of polyurethane foam as an antimicrobial dressing material in hand surgery

    Directory of Open Access Journals (Sweden)

    Nebil Yesiloglu

    2015-12-01

    Full Text Available Polyurethane foam is generally used in negative pressure-assisted wound closure therapy. It provides an antimicrobial environment around the wound, while reducing the rate of skin maceration. The authors used polyurethane foam in routine hand dressings after hand surgery operations that were performed for both congenital and acquired purposes. [Hand Microsurg 2015; 4(3.000: 91-92

  18. Polyurethanes irradiation by accelerated electrons: molecular and supramolecular evolution, incidence on the extractable and biomedical implications

    International Nuclear Information System (INIS)

    Guignot, C.

    2002-11-01

    Face to the development of radiosterilization and polymers medical devices it was wished to study the behavior of polyurethanes under accelerated electrons in oxidizing atmosphere. This study has been made to reveal the physico chemical and organisational modifications of polyurethanes for a medical use. (N.C.)

  19. The reactive extrusion of thermoplastic polyurethane and the effect of the depolymerization reaction

    NARCIS (Netherlands)

    Verhoeven, V. W. A.; Padsalgikar, A. D.; Ganzeveld, K. J.; Janssen, L. P. B. M.

    The reactive extrusion of thermoplastic polyurethane in a corotating twin-screw extruder was investigated. The polyurethane system consisted of a mixture of 2,4-diphenylmethane diisocyanate (2,4-MDI) and 4,4-MDI, methyl-propane-diol and a polyester polyol. An engineering extrusion model was designed

  20. Light Scattering of TiO2 Nanoparticles Embedded in Polyurethane

    DEFF Research Database (Denmark)

    Gudla, Visweswara Chakravarthy; Canulescu, Stela; Johansen, Villads Egede

    A new approach of enhancing light scattering in polyurethane polymer through the effect of TiO2 nanoparticles (NP) is explored. The TiO2 NP with sizes of 360 nm, 410 nm and 500 nm were dispersed in polyurethane polymer in concentrations ranging from 0.25 wt% up to 2 wt%. Reflectivity and UV-visible...

  1. The study of the curing of the polyurethane coating by method of IR spectroscopy

    Directory of Open Access Journals (Sweden)

    N. A. Korshunova

    2016-12-01

    Full Text Available The results of the study of the curing process of polyurethane compositions with participation of two different catalysts by the method of IR spectroscopy are given. The time dependences of curing of polyurethane coatings from concentrations of catalysts were determined, on the basis of which the most effective catalyst was selected.

  2. Endoscopic removal of a proximal urethral stent using a holmium laser: Case report and literature review

    Directory of Open Access Journals (Sweden)

    Francisco Botelho

    2012-01-01

    Full Text Available Urethral stents were initially developed for the management of urethral strictures and obstructive voiding disorders in select patients. Urethral stent complications are common and may require stent explantation, which is often quite challenging. We present our experience with endoscopic removal of an encrusted UroLume proximal urethral stent in a 72-year-old male using a holmium laser. The literature on various management options and outcomes for urethral stent removal is reviewed. Endoscopic removal of proximal urethral stents is feasible and safe and should be considered as the primary treatment option in patients requiring stent extraction.

  3. Y-stent-assisted coil embolisation of wide-necked aneurysms using a new fully retrievable and detachable intracranial stent: report of two cases.

    Science.gov (United States)

    Muda, Ahmad Sobri; Ralib, Ahmad Razali Md; Yaacob, Yazmin; Zakaria, Rozman; Bakar, Azizi Abu

    2011-10-01

    Endovascular treatment of wide-necked aneurysms poses a challenge for the endovascular therapist. The Y-stent-assisted technique has been used for stent-assisted coil embolisation for wide-necked bifurcation aneurysms. This technique has been described for basilar tip aneurysms and middle cerebral artery bifurcation aneurysms using Neuroform and Enterprise stents. We report 2 cases of wide-necked bifurcation aneurysms that were treated with Y-stent-assisted coil embolisation using a new, fully retrievable and detachable intracranial stent (Solitaire AB™). We describe the advantages of a fully retrievable and detachable stent and its feasibility of forming a Y configuration.

  4. Type D personality predicts death or myocardial infarction after bare metal stent or sirolimus-eluting stent implantation

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Lemos, Pedro A; van Vooren, Priya R

    2004-01-01

    We investigated the effect of Type D personality on the occurrence of adverse events at nine months in patients with ischemic heart disease (IHD) after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SESs) or bare stents. Type D patients experience increased negative...... emotions and tend not to express these emotions in social interactions....

  5. Bronchoscopic guidance of endovascular stenting limits airway compression.

    Science.gov (United States)

    Ebrahim, Mohammad; Hagood, James; Moore, John; El-Said, Howaida

    2015-04-01

    Bronchial compression as a result of pulmonary artery and aortic arch stenting may cause significant respiratory distress. We set out to limit airway narrowing by endovascular stenting, by using simultaneous flexible bronchoscopy and graduated balloon stent dilatation, or balloon angioplasty to determine maximum safe stent diameter. Between August 2010 and August 2013, patients with suspected airway compression by adjacent vascular structures, underwent CT or a 3D rotational angiogram to evaluate the relationship between the airway and the blood vessels. If these studies showed close proximity of the stenosed vessel and the airway, simultaneous bronchoscopy and graduated stent re-dilation or graduated balloon angioplasty were performed. Five simultaneous bronchoscopy and interventional catheterization procedures were performed in four patients. Median age/weight was 33 (range 9-49) months and 14 (range 7.6-24) kg, respectively. Three had hypoplastic left heart syndrome, and one had coarctation of the aorta (CoA). All had confirmed or suspected left main stem bronchial compression. In three procedures, serial balloon dilatation of a previously placed stent in the CoA was performed and bronchoscopy was used to determine the safest largest diameter. In the other two procedures, balloon testing with simultaneous bronchoscopy was performed to determine the stent size that would limit compression of the adjacent airway. In all cases, simultaneous bronchoscopy allowed selection of an ideal caliber of the stent that optimized vessel diameter while minimizing compression of the adjacent airway. In cases at risk for airway compromise, flexible bronchoscopy is a useful tool to guide endovascular stenting. Maximum safe stent diameter can be determined without risking catastrophic airway compression. © 2014 Wiley Periodicals, Inc.

  6. Assessment of Vascular Stent Heating with Repetitive Transcranial Magnetic Stimulation.

    Science.gov (United States)

    Varnerin, Nicole; Mirando, David; Potter-Baker, Kelsey A; Cardenas, Jesus; Cunningham, David A; Sankarasubramanian, Vishwanath; Beall, Erik; Plow, Ela B

    2017-05-01

    A high proportion of patients with stroke do not qualify for repetitive transcranial magnetic stimulation (rTMS) clinical studies due to the presence of metallic stents. The ultimate concern is that any metal could become heated due to eddy currents. However, to date, no clinical safety data are available regarding the risk of metallic stents heating with rTMS. We tested the safety of common rTMS protocols (1 Hz and 10 Hz) with stents used commonly in stroke, nitinol and elgiloy. In our method, stents were tested in gelled saline at 2 different locations: at the center and at the lobe of the coil. In addition, at each location, stent heating was evaluated in 3 different orientations: parallel to the long axis of coil, parallel to the short axis of the coil, and perpendicular to the plane of the coil. We found that stents did not heat to more than 1°C with either 1 Hz rTMS or 10 Hz rTMS in any configuration or orientation. Heating in general was greater at the lobe when the stent was oriented perpendicularly. Our study represents a new method for ex vivo quantification of stent heating. We have found that heating of stents was well below the Food and Drug Administration standards of 2°C. Thus, our study paves the way for in vivo testing of rTMS (≤10 Hz) in the presence of implanted magnetic resonance imaging-compatible stents in animal studies. When planning human safety studies though, geometry, orientation, and location relative to the coil would be important to consider as well. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  7. Neuroendoscopic stent placement for cerebrospinal fluid pathway obstructions in adults.

    Science.gov (United States)

    Marx, Sascha; Fleck, Steffen K; El Refaee, Ehab; Manwaring, Jotham; Vorbau, Christina; Fritsch, Michael J; Gaab, Michael R; Schroeder, Henry W S; Baldauf, Joerg

    2016-09-01

    OBJECTIVE Since its revival in the early 1990s, neuroendoscopy has become an integral component of modern neurosurgery. Endoscopic stent placement for treatment of CSF pathway obstruction is a rarely used and underestimated procedure. The authors present the first series of neuroendoscopic intracranial stenting for CSF pathway obstruction in adults with associated results and complications spanning a long-term follow-up of 20 years. METHODS The authors retrospectively reviewed a prospectively maintained clinical database for endoscopic stent placement performed in adults between 1993 and 2013. RESULTS Of 526 endoscopic intraventricular procedures, stents were placed for treatment of CSF disorders in 25 cases (4.8%). The technique was used in the management of arachnoid cysts (ACs; n = 8), tumor-related CSF disorders (n = 13), and hydrocephalus due to stenosis of the foramen of Monro (n = 2) or aqueduct (n = 2). The mean follow-up was 87.1 months. No deaths or infections occurred that were related to endoscopic placement of intracranial stents. Late stent dislocation or migration was observed in 3 patients (12%). CONCLUSIONS Endoscopic intracranial stent placement in adults is rarely required but is a safe and helpful technique in select cases. It is indicated when reliable and long-lasting restoration of CSF pathway obstructions cannot be achieved with standard endoscopic techniques. In the treatment of tumor-related hydrocephalus, it is a good option to avoid reclosure of the restored CSF pathway by tumor growth. Currently, routine stent placement after endoscopic fenestration of ACs is not recommended. Stent placement for treatment of CSF disorders due to tumor is a good option for avoiding CSF shunting. To avoid stent migration and dislocation, and to allow for easy removal if needed, the device should be fixed to a bur hole reservoir.

  8. Fluoroscopic guidance of retrograde exchange of ureteral stents in women.

    Science.gov (United States)

    Chang, Ruey-Sheng; Liang, Huei-Lung; Huang, Jer-Shyung; Wang, Po-Chin; Chen, Matt Chiung-Yu; Lai, Ping-Hong; Pan, Huay-Ben

    2008-06-01

    The purpose of this study was to review our experience with fluoroscopically guided retrograde exchange of ureteral stents in women. During a 48-month period, 28 women (age range, 38-76 years) were referred to our department for retrograde exchange of a ureteral stent. The causes of urinary obstruction were tumor compression in 26 patients and benign fibrotic stricture in two patients. A large-diameter snare catheter (25-mm single loop or 18- to 35-mm triple loop) or a foreign body retrieval forceps (opening width, 11.3 mm) was used to grasp the bladder end of the stent under fluoroscopic guidance. The technique entailed replacement of a patent or occluded ureteral stent with a 0.035- or 0.018-inch guidewire with or without the aid of advancement of an angiographic sheath. A total of 54 ureteral stents were exchanged with a snare catheter in 42 cases or a forceps in 12 cases. One stent misplaced too far up the ureter was replaced successfully through antegrade percutaneous nephrostomy. Ten occluded stents, including one single-J stent, were managed with a 0.018-inch guidewire in three cases, advancement of an angiographic sheath over the occluded stent into the ureter in five cases, and recannulation of the ureteral orifice with a guidewire in two cases. No complications of massive hemorrhage, ureter perforation, or infection were encountered. With proper selection of a snare or forceps catheter, retrograde exchange of ureteral stents in women can be easily performed under fluoroscopic guidance with high technical success and a low complication rate.

  9. Use of tracheal stenting in the palliation of anaplastic thyroid carcinoma: tertiary centre experience.

    Science.gov (United States)

    Varadharajan, K; Mathew, R; Odutoye, B; Williamson, P; Madden, B

    2015-06-01

    Anaplastic thyroid carcinoma is rare but carries a poor prognosis. Anaplastic thyroid carcinoma leads to tracheal compression, airway compromise and eventually death. Airway compromise, a particularly distressing symptom, can be palliated with tracheal stenting. A retrospective case note analysis was conducted of patients diagnosed with anaplastic thyroid carcinoma between July 2003 and July 2013. Twelve patients with anaplastic thyroid carcinoma were identified. Four patients underwent palliative tracheal stenting. Three patients had no dyspnoea at the time of stenting. Two stented patients subsequently developed dyspnoea secondary to stent migration; this was managed successfully with stent exchange. The other stented patient remained asymptomatic with regards to dyspnoea. All non-stented patients died with or from airway compromise. Tracheal stenting is a relatively safe and effective method for palliation of distressing airway symptoms in patients with anaplastic thyroid carcinoma. Early prophylactic tracheal stenting in anaplastic thyroid carcinoma may be an effective option to prevent development of airway compromise as the disease progresses.

  10. Preparation and characterization of polyurethane plasticizer for flexible packaging applications: Natural oils affirmed access

    Directory of Open Access Journals (Sweden)

    Mohammed A. Mekewi

    2017-03-01

    Full Text Available Developing bio-renewable feedstock for polyurethane (PU manufacturing and polymer industry as a whole has become highly desirable for both economic and environmental reasons. In this work castor oil (CO and palm olein (PO polyols were synthesized and partially used as renewable feedstock for the manufacturing of polyurethane plasticizing resin for printing ink applications. The chemical structure of the prepared polyols and polyurethanes were characterized using IR spectra and GPC and their solubility in common solvents was tested. As well, properties such as flexibility, mechanical properties, optical properties, heat seal and freeze resistance of these prepared printing inks were determined. The results indicated that the prepared printing inks from 50% synthesized polyurethane have high thermal stability, adhesion and excellent freeze resistance. The net technical properties of the new ink formulations are relatively comparable to the printing ink prepared from standard polyurethane plasticizer.

  11. Synthesis and Characterization of Anionic Polyester-Polyurethane Dispersion as Environmentally-Friendly Waterbased Resins

    Directory of Open Access Journals (Sweden)

    Najaf i F. Manouchehri F., and Shaabanz

    2012-01-01

    Full Text Available Aqueous polyurethane dispersions (PUDs have recently emerged as important alternatives to their solvent-based counterparts for various applications due to increasing health and environmental awareness (green chemistry. Anionic polyester-polyurethane dispersions were synthesized by three steps. In the first step, macromonomer diisocyanate having carboxylic acid was prepared by isophorone diisocyanate (IPDI, dimethylol propionic acid (DMPA in percent of acetone as solvent and dibutyldtin dilaurate (DBTDL as catalyst. Then, carboxylic polyurethane was prepared by reaction macromonomer diisocyanate having carboxylic acid with linear aliphatic polyester (Mw=2000, trifunctional polyester (Mw=2800 and butanediol (BDO as chain extender. The next step involved neutralization and dispersion in water, where acidic polyurethane was neutralized by the addition of triethylamine (TEA.  Factors influencing the synthesis of polyurethane dispersion mainly involve reaction temperature, reaction time, the concentration of catalyst, DMPA content and BDO content, were studied. The polymers have been characterized with DSC and FTIR.

  12. Experimental study of polyurethane foam reinforced soil used as a rock-like material

    Directory of Open Access Journals (Sweden)

    Eren Komurlu

    2015-10-01

    Full Text Available In this study, polyurethane foam type thermoset polymerizing, due to chemical reaction between its liquid ingredients, was tested as binder after solidifying and then a rock-like material mixing with a sandy silt type soil was prepared. The uniaxial compressive strengths (UCSs of polyurethane foam reinforced soil specimens were determined for different polyurethane ratios in the mixture. Additionally, a series of tests on slake durability, impact value, freezing–thawing resistance, and abrasion resistance of polyurethane reinforced soil (PRS mixture was conducted. The UCS values over 3 MPa were measured from the PRS specimens. The testing results showed that treated soil can economically become a desirable rock-like material in terms of slake durability and resistances against freezing–thawing, impact effect and abrasion. As another characteristic of the rock-like material made with polyurethane foam, unit volume weight was found to be quite lower than those of natural rock materials.

  13. Reflectance spectroscopy from TiO2 particles embedded in polyurethane

    DEFF Research Database (Denmark)

    Gudla, Visweswara Chakravarthy; Canulescu, Stela; Johansen, Villads Egede

    2013-01-01

    This paper presents the results of a physical simulation carried out using TiO2-Polyurethane composite coating on bright aluminium surface to understand the light scattering effect for designing white surfaces. Polyurethane matrix is selected due to the matching refractive index (1.7) with Al2O3...... layer on anodized aluminium surfaces. Three different TiO2 particle distributions were dispersed in polyurethane and spin coated onto high gloss and caustic etched aluminium substrates. Reflectance spectra of TiO2-polyurethane films of various concentrations were analysed using an integrating sphere....... The results show that the TiO2-polyurethane coatings have a high diffuse reflectance as a result of multiple scattering from TiO2 particles. Diffuse reflectance spectra of TiO2 containing films vary weakly with particle concentration and reach a steady state value at a concentration of 0.75 wt.%. Using...

  14. SPECIFIC FEATURES OF OLIGOMERIC PRODUCT SOLIDIFICATION FROM POLYURETHANE WASTES AND THEIR PRACTICAL APPLICATION

    Directory of Open Access Journals (Sweden)

    V. Belyatsky

    2012-01-01

    Full Text Available The paper considers a possibility to use secondary polyurethane obtained by  thermal depolymerization of wastes on the basis of cross-linked polyurethane (polyurethane adduct and isocyanate. An effect of density dependence of the obtained polyurethane samples on nature and quantity of solvent has been revealed and it is significantly observed while using low-boiling solvents. The influence of adduct/solidification agent ratio on mechanical hardness of the obtained samples has been studied in the paper. The paper shows that the most optimal ratio is within the following limits – from 7/1 to 10/1. Plasticizing effect of polyurethane adduct on bitumen materials has been also found in the paper.A conclusion has been made that there is a possibility of practical usage of composites in building and road-building materials. 

  15. Automated detection of vessel lumen and stent struts in intravascular optical coherence tomography to evaluate stent apposition and neointimal coverage

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Hyeong Soo; Kim, Chang-Soo; Yoo, Hongki, E-mail: kjwmm@korea.ac.kr, E-mail: hyoo@hanyang.ac.kr [Department of Biomedical Engineering, Hanyang University, Seoul 04763 (Korea, Republic of); Lee, Jae Joong; Song, Joon Woo; Kim, Jin Won, E-mail: kjwmm@korea.ac.kr, E-mail: hyoo@hanyang.ac.kr [Division of Interventional Cardiology, Cardiovascular Center, Korea University Guro Hospital, Seoul 08308 (Korea, Republic of)

    2016-04-15

    Purpose: Intravascular optical coherence tomography (IV-OCT) is a high-resolution imaging method used to visualize the microstructure of arterial walls in vivo. IV-OCT enables the clinician to clearly observe and accurately measure stent apposition and neointimal coverage of coronary stents, which are associated with side effects such as in-stent thrombosis. In this study, the authors present an algorithm for quantifying stent apposition and neointimal coverage by automatically detecting lumen contours and stent struts in IV-OCT images. Methods: The algorithm utilizes OCT intensity images and their first and second gradient images along the axial direction to detect lumen contours and stent strut candidates. These stent strut candidates are classified into true and false stent struts based on their features, using an artificial neural network with one hidden layer and ten nodes. After segmentation, either the protrusion distance (PD) or neointimal thickness (NT) for each strut is measured automatically. In randomly selected image sets covering a large variety of clinical scenarios, the results of the algorithm were compared to those of manual segmentation by IV-OCT readers. Results: Stent strut detection showed a 96.5% positive predictive value and a 92.9% true positive rate. In addition, case-by-case validation also showed comparable accuracy for most cases. High correlation coefficients (R > 0.99) were observed for PD and NT between the algorithmic and the manual results, showing little bias (0.20 and 0.46 μm, respectively) and a narrow range of limits of agreement (36 and 54 μm, respectively). In addition, the algorithm worked well in various clinical scenarios and even in cases with a low level of stent malapposition and neointimal coverage. Conclusions: The presented automatic algorithm enables robust and fast detection of lumen contours and stent struts and provides quantitative measurements of PD and NT. In addition, the algorithm was validated using

  16. Pooled analysis of two randomized trials comparing titanium-nitride-oxide-coated stent versus drug-eluting stent in STEMI.

    Science.gov (United States)

    Tuomainen, Petri O; Sia, Jussi; Nammas, Wail; Niemelä, Matti; Airaksinen, Juhani K E; Biancari, Fausto; Karjalainen, Pasi P

    2014-07-01

    We performed a pooled analysis based on patient-level data from the TITAX-AMI and BASE-ACS trials to evaluate the outcome of titanium-nitride-oxide-coated bioactive stents vs drug-eluting stents in patients with ST-segment elevation myocardial infarction at 2-year follow-up. The TITAX-AMI trial compared bioactive stents with paclitaxel-eluting stents in 425 patients with acute myocardial infarction. The BASE-ACS trial compared bioactive stents with everolimus-eluting stents in 827 patients with acute coronary syndrome. The primary endpoint for the pooled analysis was major adverse cardiac events: a composite of cardiac death, recurrent myocardial infarction, or ischemia-driven target lesion revascularization at 2-year follow-up. The pooled analysis included 501 patients; 245 received bioactive stents, and 256 received drug-eluting stents. The pooled bioactive stent group was associated with a risk ratio of 0.85 for major adverse cardiac events (95% confidence interval, 0.53-1.35; P=.49) compared to the pooled drug-eluting stent group. Similarly, the pooled bioactive stent group was associated with a risk ratio of 0.71 for cardiac death (95% confidence interval, 0.26-1.95; P=.51), 0.44 for recurrent myocardial infarction (95% confidence interval, 0.20-0.97; P=.04), and 1.39 for ischemia-driven target lesion revascularization (95% confidence interval, 0.74-2.59; P=.30), compared to the pooled drug-eluting stent group. These results were confirmed by propensity-score adjusted analysis of the combined datasets. In patients with ST-segment elevation myocardial infarction, bioactive stents were associated with lower rates of recurrent myocardial infarction compared to drug-eluting stents at 2-year follow-up; yet, the rates of cardiac death and ischemia-driven target lesion revascularization were similar. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  17. Complication rate in unprotected carotid artery stenting with closed-cell stents

    International Nuclear Information System (INIS)

    Tietke, Marc W.K.; Kerby, Tina; Alfke, Karsten; Riedel, Christian; Rohr, Axel; Jensen, Ulf; Jansen, Olaf; Zimmermann, Phillip; Stingele, Robert

    2010-01-01

    The discussion on the use of protection devices (PDs) in carotid artery stenting (CAS) is gaining an increasing role in lowering the periprocedural complication rates. While many reviews and reports with retrospective data analysis do promote the use of PDs the most recent multi-centre trials are showing advantages for unprotected CAS combined with closed-cell stent designs. We retrospectively analysed 358 unprotected CAS procedures performed from January 2003 to June 2009 in our clinic. Male/female ratio was 2.68/1. The average age was 69.3 years. Seventy-three percent (261/358) showed initial neurological symptoms. All patients were treated on a standardised interventional protocol. A closed and small-sized cell designed stent was implanted in most cases (85.2%). One hundred seventy-one (47.8%) were controlled by Doppler ultrasonography usually at first in a 3-month and later in 6-month intervals. The peri-interventional and 30-day mortality/stroke rate was 4.19% (15/358). These events included three deaths, five hyperperfusion syndromes (comprising one death by a secondary fatal intracranial haemorrhage), one subarachnoid haemorrhage and seven ischaemic strokes. Only 20% (3/15) of all complications occurred directly peri-interventional. The overall peri-interventional complication rate was 0.8% (3/358). Most complications occurred in initial symptomatic patients (5.36%). The in-stent restenosis rate for more than 70% was 7% (12/171) detected at an average of 9.8 month. Our clinical outcome demonstrates that unprotected CAS with small cell designed stents results in a very low procedural complication rate, which makes the use of a protection device dispensable. (orig.)

  18. Resolution of Metallic Biliary Stent Allergic Reaction After Partial Stent Removal in a Patient with Nickel Sensitivity.

    Science.gov (United States)

    Esparaz, Anthony M; Ahmed, Muneeb

    2017-07-01

    Local and systemic reactions to implanted metallic devices, particularly to those containing nickel, are well documented. Metal ions are released due to exposure of the metal to blood, proteins, other body fluids, and sheer mechanical stress. Metal ions then complex with native proteins and become antigens, which can elicit hypersensitivity reactions. Another case report depicts a specific allergic complication (early stent occlusion) related to metallic biliary stent implantation. We present a case of allergic symptoms, associated with eating, in a patient who developed nickel sensitivity after biliary metal stent placement confirmed by allergic skin testing to the same metallic biliary stent placed one year earlier. Symptoms resolved following partial removal of the non-epithelialized portion of the biliary stent.

  19. Histopathological reaction over prosthesis surface covered with silicone and polyurethane foam implanted in rats.

    Science.gov (United States)

    Wagenführ-Júnior, Jorge; Ribas Filho, Jurandir Marcondes; Nascimento, Marcelo Mazza do; Ribas, Fernanda Marcondes; Wanka, Marcus Vinícius; Godoi, Andressa de Lima

    2012-12-01

    To evaluate whether polyurethane foam leads more intense foreign-body reaction than silicone foam. To compare the vascularization of the capsules surrounding the foam implants. To investigate if the capsule of polyurethane foam implanted has greater amount of collagen than that of silicone foam. Sixty-four young male Wistar rats were allocated into two groups: polyurethane foam and silicone foam. Subcutaneous discs were implanted into the dorsum of the animals in both groups. The capsules were assessed 28 days, two months, three months and six months postoperatively. Microscopic analysis with H&E stain was performed to evaluate the acute and chronic inflammatory process, foreign-body reaction and neovascularization. The analysis with picrosirius red was performed using the ImageProPlus software, to measure the number of vessels and collagen types I and III. There were no statistical differences between the two groups regarding the acute and chronic inflammatory processes. All rats from the polyurethane group, in all times, exhibited moderate or intense foreign-body reaction, with statistic significant difference (p=0.046) when compared with the silicone group, in which the reaction was either mild or nonexistent at two months. Vascular proliferation was significantly different between the groups at 28 days (p=0.0002), with the polyurethane group displaying greater neovascularization with H&E stain. Similar results were obtained with picrosirius red, which revealed in the polyurethane group a much greater number of vessels than in the silicone group (p=0.001). The collagen area was larger in the polyurethane group, significantly at 28 days (p=0.001) and at two months (p=0.030). Polyurethane foam elicited more intense foreign-body reaction when compared with silicone foam. The number of vessels was higher in the capsules of the polyurethane foam implants 28 days after the operation. The capsule of the polyurethane foam implants showed a greater amount of collagen

  20. Treatment of malignant gastroduodenal obstruction with using a newly designed complex expandable nitinol stent: initial experiences

    International Nuclear Information System (INIS)

    Jung, Mi Hee; Ko, Ji Ho; Lee, Eun Jung; Oh, Kyeng Seung; Huh, Jin Do; Cho, Young Duk; Park, Seun Ja; Jung, Gyoo Sik

    2005-01-01

    We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake capacity before and after the procedure. The complications were investigated during the follow up period. Stent placement was successful in all the patients. After stent placement, the symptoms improved in all but one patient. During the follow up, stent migration occurred in one patient (3%) at 34 days after the procedure. Despite the stent migration, the patient was able to resume a soft diet. Six patients developed recurrent symptoms of obstruction with tumor overgrowth at a mean of 145 days after the procedure; all the patients underwent coaxial placement of an additional stent with good results. One patient showed recurrence of obstruction due to tumor in-growth, and this was treated by placement of a second stent. Two patients with stent placement in the duodenum suffered from jaundice 26 days and 65 days, respectively, after their procedures. Placement of the newly designed complex expandable nitinol stent seems to be effective for the palliative treatment of malignant gastroduodenal obstructions. The new stent also seems to help overcome the

  1. Biodegradable stents made of pure Mg and AZ91 alloy through SPS sintering

    OpenAIRE

    de Oliveira Botelho, Pedro Augusto

    2015-01-01

    The implantation of stents is an effective procedure to unblock the arteries of patients with serious heart problems. Traditionally, stents are made of inert materials such as stainless steel and titanium alloys. It has been shown that the traditional stents can cause restenosis or thrombosis. In recent years the proposal of biodegradable stents is attracting the interest of the industry and the research, since the stent is mechanically needed only in the first year, eliminating the problems ...

  2. Treatment of malignant gastroduodenal obstruction with using a newly designed complex expandable nitinol stent: initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Mi Hee; Ko, Ji Ho; Lee, Eun Jung; Oh, Kyeng Seung; Huh, Jin Do; Cho, Young Duk; Park, Seun Ja [College of Medicine, Kosin University, Busan (Korea, Republic of); Jung, Gyoo Sik [Ulsan Hospital, Ulsan (Korea, Republic of)

    2005-12-15

    We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake capacity before and after the procedure. The complications were investigated during the follow up period. Stent placement was successful in all the patients. After stent placement, the symptoms improved in all but one patient. During the follow up, stent migration occurred in one patient (3%) at 34 days after the procedure. Despite the stent migration, the patient was able to resume a soft diet. Six patients developed recurrent symptoms of obstruction with tumor overgrowth at a mean of 145 days after the procedure; all the patients underwent coaxial placement of an additional stent with good results. One patient showed recurrence of obstruction due to tumor in-growth, and this was treated by placement of a second stent. Two patients with stent placement in the duodenum suffered from jaundice 26 days and 65 days, respectively, after their procedures. Placement of the newly designed complex expandable nitinol stent seems to be effective for the palliative treatment of malignant gastroduodenal obstructions. The new stent also seems to help overcome the

  3. High frequency of contact allergy to gold in patients with endovascular coronary stents.

    Science.gov (United States)

    Ekqvist, S; Svedman, C; Möller, H; Kehler, M; Pripp, C M; Björk, J; Gruvberger, B; Holmström, E; Gustavsson, C G; Bruze, M

    2007-10-01

    Stent implantation is an effective method for treatment of atherosclerotic disease. Factors predisposing to in-stent restenosis are still largely unknown. Contact allergy to metal ions eluted from the stent has been suggested to be a risk factor. To explore whether there is a possible induction of contact allergy to metals used in stents among patients with a stainless steel stent containing nickel (Ni stent) and patients with a gold-plated stent (Au stent). Adults (n = 484) treated with coronary stent implantation participated in the study with patch testing. The study design was retrospective and cross-sectional with no assessment of contact allergy before stenting. Age- and sex-matched patch-tested patients with dermatitis (n = 447) served as controls. Of Au-stented patients, 54 of 146 (37%) were allergic to gold compared with 85 of 447 (19%) controls (P stented population there were no statistically significant differences in contact allergy to gold or nickel between Ni-stented and Au-stented patients. In multivariate models where other risk factors for contact allergy to gold were considered, the Au stent showed a trend towards statistical significance (odds ratio 1.43, 95% confidence interval 0.95-2.16; P = 0.09). As the frequency of contact allergy to gold is higher in stented patients independent of stent type it suggests a previous sensitization. However, several pieces of circumstantial evidence as well as statistical analysis indicate the possibility of sensitization in the coronary vessel by the Au stent. Ni stents and Au stents should not be ruled out as risk factors for induction of contact allergy to these metals.

  4. Coil Migration through a Neuroform 3 Stent during Endovascular Coiling. A Case Report.

    LENUS (Irish Health Repository)

    O'Hare, A

    2009-07-29

    Summary: A 43-year-old woman attended for stent assisted coiling. A Neuroform 30 x 4.5 mm stent had been successfully placed over the left periophthalmic aneurysm. During the coiling the first coil migrated through the crowns in the stent, lodging at the MCA bifurcation. We believe that the coil herniated through the overlying stent due to the carotid siphon curvature and the open cell design. Furthermore the distal markers of the stent impeded coil extraction with a MERCI device.

  5. Hemi-Intravascular Stenting for Supermicrosurgical Anastomosis

    Science.gov (United States)

    Yamashita, Shuji; Narushima, Mitsunaga; Koshima, Isao; Miyamoto, Shimpei

    2017-01-01

    Background: Although supermicrosurgical anastomosis is a widely known reconstructive microsurgical technique, it is difficult to perform. To expand the clinical use of supermicrosurgery, we used hemi-intravascular stenting (hemi-IVaS), which is performed by inserting an intravascular stent into one side of the vessel. We conducted lymphaticovenular anastomosis, free perforator flap transfer, and fingertip replantation with supermicrosurgical anastomosis using hemi-IVaS technique and examined its usefulness. Methods: Between January 2013 and February 2015, 11 anastomoses in 11 cases of lymphaticovenular anastomosis for lymphedema patients, 14 anastomoses in 7 cases of free perforator flap transfer with supermicrosurgical perforator-to-perforator anastomosis, and 9 anastomoses in 5 cases of fingertip replantation were performed using hemi-IVaS. Time required for anastomosis and complications were examined. Flap survival rate was also examined in free perforator flap transfer cases and fingertip replantation cases. Results: In all cases, anastomoses were performed without complications such as inadvertent catching of the back wall of the vessel during the procedure or the need for reanastomoses. The average time required to complete the anastomosis was 16.4 ± 3.20 minutes using the hemi IVaS technique. All flaps survived in the supermicrosurgical perforator-to-perforator anastomosis as well as fingertip replantation cases. Conclusions: Hemi-IVaS could be a useful alternative to conventional intravascular stenting techniques and is also effective for supermicrosurgical perforator-to-perforator anastomosis. Further studies are needed to improve the success rate and to explore its other possible utilizations in supermicrosurgery. PMID:29263952

  6. Internal biliary stenting in liver transplantation.

    Science.gov (United States)

    Girard, Edouard; Risse, Olivier; Abba, Julio; Medici, Maud; Leroy, Vincent; Chirica, Mircea; Letoublon, Christian

    2018-03-24

    Internal biliary stenting (IBS) was reported to decrease biliary complications after liver transplantation (LT) but data in literature is scarce. The aim of the present study was to evaluate our experience with end-to-end choledoco-choledocostomy during liver transplantation with special focus on the influence of IBS on patient and biliary outcomes. Between 2009 and 2013, 175 patients underwent deceased donor LT with end-to-end choledoco-choledocostomy and were included in the study. Supra-papillary silastic stent was inserted in 67 patients (38%) with small-size (< 5 mm) bile ducts (recipient or donor). Endoscopic retrograde cholangiopancreatography (ERCP) was scheduled for IBS removal, 6 months after LT. Operative outcomes and survival of patients who received internal stenting (IBS group) were compared with those of patients who did not (no-IBS group). Risk factors for biliary anastomotic complications were identified. Ten patients died (6%) and 104 (59%) experienced postoperative complications. Five-year patient and graft survival rates were 77 and 74%, respectively. Biliary complications were recorded in 61 patients (35%) and were significantly decreased by IBS insertion (p = 0.0003). Anastomotic fistulas occurred in 23 patients (13%) and stenoses in 44 patients (25%). On multivariate analysis, high preoperative MELD scores (p = 0.02) and hepatic artery thrombosis (p < 0.0001) were predictors of fistula; absence of IBS was associated with both fistula (p = 0.014) and stricture (p = 0.003) formation. IBS insertion during LT decreases anastomotic complication.

  7. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction: A Comparison Between 2 Brands of Stents.

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-07-01

    Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group.

  8. The effect of stent structure changes on the hemodynamics and the formation of in-stent restenosis

    International Nuclear Information System (INIS)

    Wu Xia; Xu Ke; Xiao Liang; Zhang Xitong; Su Hongying; Feng Bo

    2009-01-01

    Objective: To investigate the effect of stent structure changes on the formation of in-stent restenosis by studying the influence of these changes on the shear force to the vascular wall, on the velocity of flow and on the flow pattern. Methods: Five stent models were established by using Pro/engineer wildfire 3.0. Model A was regarded as control structure. On the base structure of model A, transverse link component was added to form model B, and vertical link component was added to form model C. The thickness of model D was twice than that of model A, and the meshes density of model E was twice than that of model A. Fluid models were built up by importing these stent models into computational fluid dynamics (CFD) software ansys11.0-CFX, then, CFD analysis was proceeded to study the effect of stent structure on hemodynamics. Results: After the stents were implanted, the percentage of low wall shear stress on the surface of model A, B, C, D and E was 7.78%, 6.65%, 1.48%, 16.52% and 12.12%, respectively. The percentage of D and E was obviously larger than that of A, while the percentage of B was markedly smaller than that of A. The velocity vector on the cross-sectional planes showed that the low velocity and eddy areas in D and E were much larger than that in A, while this area in C was smaller than that in A. Conclusion: The stent structure changes can cause obvious changes in hemodynamics in the implanted vessels. The increase in the thickness and meshes density of the stent is the main factor that induces the formation of low wall shear stress, which will precipitate the development of in-stent restenosis. The added vertical link component will reduce the area of low wall shear stress as well as the occurrence of in-stent restenosis. (authors)

  9. TACE Combined with Implantation of Irradiation Stent Versus TACE Combine with Bare Stent for HCC Complicated by IVCTT

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Qing-hui; Zhang, Wen; Liu, Qing-xin; Liu, Ling-xiao [Fudan University, Department of Interventional Radiology, Zhongshan Hospital (China); Wu, Lin-lin [Tengzhou Central People’s Hospital, Department of Oncology (China); Wang, Jian-hua; Yan, Zhi-ping, E-mail: 798373254@qq.com; Luo, Jian-jun, E-mail: 12211210022@fudan.edu.cn [Fudan University, Department of Interventional Radiology, Zhongshan Hospital (China)

    2016-09-15

    PurposeThis study was designed to evaluate the safety and efficacy of transarterial chemoembolization (TACE) combined with intra-IVC implantation of an irradiation stent for the treatment of hepatocellular carcinoma (HCC) complicated by inferior vena cava tumor thrombosis (IVCTT).MethodsSixty-one consecutive patients with HCC complicated by IVCTT treated by TACE combined with IVC stenting were retrospectively analysed. IVC stenting was performed using a stent loaded with {sup 125}I seeds strands (the irradiation stent) in 33 patients (Group A) and 28 patients with a bare stent (Group B). Propensity score matching eliminated the baseline differences. Overall survival, oedema related to IVC obstruction remission rate and procedure-related adverse events were compared between the two groups.ResultsThe adverse effect rate was similar for both Group A and Group B patients, and complications were adequately handled by medical treatment. TACE combined with implantation of an irradiation stent showed a significant median survival benefit over TACE combined with a bare stent, with a median survival time of 203.0 ± 28.135 days versus 93.0 ± 24.341 days (p = 0.006). The propensity score-matched (24 pairs) cohort analyses (200 ± 31.231 days vs. 66 ± 23.270 days, p = 0.019). The oedema remission rate was 97.0 % in group A patients and 96.4 % in group B, respectively. TACE-irradiation stent and object tumor response were the independent prognostic factors of favorable survival.ConclusionsTACE combined with irradiation stent implantation is a safe and effective treatment modality for patients with HCC complicated by IVCTT and may extend their survival time.

  10. Enhancement of endothelialisation of coronary stents by laser surface engineering.

    Science.gov (United States)

    Li, Lin; Mirhosseini, Nazanin; Michael, Alun; Liu, Zhu; Wang, Tao

    2013-11-01

    Coronary stents have been widely used in the treatment of coronary heart disease. However, complications have hampered the long-term success of the device. Bare-metal stents (BMS) have a high rate of restenosis and poor endothelialisation. The drug-eluting stents (DES), although dramatically reduce restenosis, significantly prevent endothelialisation leading to late thrombosis and behave the same way as BMS after drug releasing. Rapid adhesion and growth of endothelial cells on the stent surface is a key process for early vascular healing after coronary stenting which contributes to the reduction of major complications. Surface properties manipulate cell growth and directly determine the success and life-span of the implants. However, the ideal surface properties of coronary stents are not yet fully understood. The objective of this research is to understand how surface micro/nano textures and associated material chemistry changes generated by a laser beam affect the behavior of endothelial cells on bare metal 316L stents. A high power laser beam was applied to modifying the surface properties of 316L coronary stent material and the commercial coronary stents, followed by examination of the adhesion and proliferation of human coronary endothelial cells that were growing on the surfaces. Surface properties were examined by scanning electron microscopy, contact angle measurement, and X-ray photoelectron spectroscopy. A novel surface with combined micro/nano features was created on stent material 316L and coronary stent with a specific surface chemistry. This surface gives rise to a threefold increase in the adhesion and eightfold increase in the proliferation of endothelial cells. Interestingly, such effects were only observed when the surface texture was produced in the nitrogen atmosphere suggesting the importance of the surface chemistry, including the dramatic increase of chromium nitride, for the interaction of endothelial cells with the material surface. This

  11. Multiple stent delivery system Multi-LOC, a new technology for spot-stenting of the femoropopliteal artery - proof of concept study in a preclinical large animal model.

    Science.gov (United States)

    Sigl, Martin; Dudeck, Oliver; Jung, Johannes; Koelble, Heinz; Amendt, Klaus

    2017-10-01

    A new stent system was studied in a porcine model to evaluate its feasibility for spot-stenting of the femoropopliteal artery. In a preliminary study in a single pig, handling and mechanical features of the novel multiple stent delivery system were tested. The Multi-LOC system demonstrated great feasibility regarding its pushability, trackability, and crossability. Excellent visibility of the individual stents allowed exact anatomically controlled implantation. In our main study, four to five short Multi-LOC stents (13 mm long) were implanted into the femoropopliteal arteries of six domestic pigs and long (60 to 100 mm) self-expandable nitinol stents were implanted into the same target vessel contralaterally to allow for intraindividual comparison. After four weeks survival under dual antiplatelet treatment, control angiography was performed. The animals were euthanized, stented vessels were explanted, and histologic sections were examined for the presence of neointimal formation. Multi-LOC stents demonstrated no occlusion of the femoropopliteal axis (0 vs. 1 occlusion distal to a control stent), no stent fractures (0 out of 26 vs. 2 out of 6 control stents), and lower percentage diameter stenosis (0.564 ± 0.056 vs. 0.712 ± 0.089; p = 0.008) and length of stenosis (19.715 ± 5.225 vs. 39.397 ± 11.182; p = 0.007) compared to a standard control stent, which was similar in total length to the multiple stented artery segment. Histological examination confirmed myointimal hyperplasia underlying in-stent stenosis. The multiple stent delivery system was studied in a porcine model, which demonstrated its feasibility. Preclinical experience revealed favourable results concerning stent fracture, restenosis, and patency of spot-stented femoropopliteal arteries.

  12. Association of stent-induced changes in coronary geometry with late stent failure: Insights from three-dimensional quantitative coronary angiographic analysis.

    Science.gov (United States)

    Zhang, Bu Chun; Tu, Sheng Xian; Karanasos, Antonios; van Geuns, Robert-Jan; de Jaegere, Peter; Zijlstra, Felix; Regar, Evelyn

    2018-02-05

    The relationship between vessel angulation and large changes in vessel geometry after stent implantation and the occurrence of stent failure still remains unclear. We sought to investigate the association of the change in the coronary bending angle after stenting and the risk for late stent failure by three-dimensional quantitative coronary angiography (3D QCA). The bending angle in coronary lesions that presented with late stent failure and those without stent failure was computed during the cardiac cycle, before and after stenting using a recently developed 3D QCA software. A total of 40 lesions with stent failure (cases) were successfully matched to 47 lesions without stent failure (controls).The mean duration to follow-up coronary angiography was 1,011 days in cases and 1,109 days in the control group (P = 0.14). In stent failure, the systolic bending angle after stenting was smaller (14.45° [12.18, 17.68] versus 18.20° [14.00, 20.30], P = 0.01), while the stent-induced change in systolic bending angle was significantly larger (4.15° [1.13, 7.20] versus 1.80° [-1.90, 4.40], P = 0.004). Multivariable logistic regression analysis suggested that systolic bending angle after stenting (odds ratio: 0.88; 95% CI: 0.79-0.99; P = 0.03), and decrease in systolic bending angle after stenting (odds ratio: 1.13; 95% CI: 1.02-1.26; P = 0.03) were predictors of stent failure. Our study suggests that a change in the natural tortuous course of the coronaries by stent implantation with the decrease in coronary bending angle is a potentially major contributor in stent failure. © 2018 Wiley Periodicals, Inc.

  13. Outcomes of second self-expandable metallic stent insertion for malignant gastric outlet obstruction.

    Science.gov (United States)

    Kim, Chan Gyoo; Choi, Il Ju; Lee, Jong Yeul; Cho, Soo-Jeong; Kim, Soo Jin; Kim, Mi-Jung; Park, Sook Ryun; Park, Young Lee

    2014-01-01

    Self-expandable metallic stents are used widely to relieve malignant gastric outlet obstruction (GOO). However, restenosis or migration of first stents is a frequent complication. The purpose of this retrospective cohort study was to evaluate the effectiveness of second stents as an approach to manage failure of first stents in patients with malignant GOO. A total of 222 patients with gastric cancer received first stents due to inoperable GOO at National Cancer Center in Korea between January 2008 and June 2011. Monthly follow-up interviews were performed, and second stents (stent-in-stent or stent-after-migration) were inserted in 59 patients by June 2012. Technical and clinical successes and long-term complications were evaluated. The technical and immediate clinical success rates were 98.3 % (58/59) and 91.5 % (54/59), respectively. Patients who received a second stent due to late complications involving the first stent (migration, restenosis, and fracture) showed a higher clinical success rate (95.8 % [46/48]) than patients who received a second stent due to immediate clinical failure of the first stent (72.7 % [8/11], p = 0.04). The immediate clinical success rate of stent-after-migration (100 % [11/11]) was not different from that of stent-in-stent (89.6 % [43/48], p = 1.0). The stent dysfunction rate of stent-after-migration (27.3 % [3/11]) also was similar to that of stent-in-stent (29.2 % [14/48], p = 1.0). The median patencies of stent-in-stent and stent-after-migration were 27.4 and 58.4 weeks, respectively (p = 0.177). There were no significant prognostic factors for patency of second stents. Insertion of a second stent is effective for treating the first-stent failure in gastric cancer patients with GOO, especially if the immediate outcome of the first stent was successful.

  14. Thalamic hemorrhage following carotid angioplasty and stenting

    International Nuclear Information System (INIS)

    Friedman, Jonathan A.; Kallmes, David F.; Wijdicks, Eelco F.M.

    2004-01-01

    Carotid angioplasty and stenting (CAS) has emerged as an alternative treatment of carotid stenosis for patients poorly suited for endarterectomy. Intracerebral hemorrhage following carotid revascularization is rare and thought to be related to hyperperfusion injury in most cases. Early experience suggests an increased incidence of hemorrhage following CAS as compared to endarterectomy. We describe a patient who suffered a thalamic hemorrhage following CAS. Because this hemorrhage occurred in a vascular territory unlikely to have been supplied by the treated artery, this case suggests that the mechanism of intracerebral hemorrhage following CAS may in some cases be different from the hyperperfusion hemorrhage classically described following endarterectomy. (orig.)

  15. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

    Science.gov (United States)

    Lemos, Pedro A; Abizaid, Alexandre A C; Meireles, George C; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D; Mariani, Jose; Perin, Marco A; Costantini, Costantino; Costa, Ricardo A; Costa, José Ribamar; Chamie, Daniel; Campos, Carlos A; Ribeiro, Expedito

    2015-12-01

    To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. © 2015 John Wiley & Sons Ltd.

  16. Release of CFC-11 from disposal of polyurethane foam waste

    DEFF Research Database (Denmark)

    Kjeldsen, Peter; Jensen, M.H.

    2001-01-01

    The halocarbon CFC-11 has extensively been used as a blowing agent for polyurethane (PUR) insulation foams in home appliances and for residential and industrial construction. Release of CFCs is an important factor in the depletion of the ozone layer. For CFC-11 the future atmospheric concentrations...... will mainly depend on the continued release from PUR foams. Little is known about rates and time frames of the CFC release from foams especially after treatment and disposal of foam containing waste products. The CFC release is mainly controlled by slow diffusion out through the PUR. From the literature...

  17. Dielectric and conductivity properties of composite polyaniline/polyurethane network

    Science.gov (United States)

    Liang, C.; Gest, J.; Leroy, G.; Carru, J.-C.

    2013-09-01

    In this work, we present the dielectric characterization of polyaniline/polyurethane composite. The samples consisting of 0.5%, 1%, and 5% of polyaniline were deposited on glass fiber, and the measurements were performed in a frequency range of 20 Hz to 20 GHz. The results showed a dielectric relaxation strongly dependent on the concentration of polyaniline. This phenomenon is explained by a theoretical model. In this model, we assume that the alternative conductivity of the polymer network systems is due to conducting clusters whose lengths followed a Gaussian distribution. Depending on their size and the frequency of the excitation signal, the clusters showed a resistive or capacitive effect.

  18. Method for providing a low density high strength polyurethane foam

    Science.gov (United States)

    Whinnery, Jr., Leroy L.; Goods, Steven H.; Skala, Dawn M.; Henderson, Craig C.; Keifer, Patrick N.

    2013-06-18

    Disclosed is a method for making a polyurethane closed-cell foam material exhibiting a bulk density below 4 lbs/ft.sup.3 and high strength. The present embodiment uses the reaction product of a modified MDI and a sucrose/glycerine based polyether polyol resin wherein a small measured quantity of the polyol resin is "pre-reacted" with a larger quantity of the isocyanate in a defined ratio such that when the necessary remaining quantity of the polyol resin is added to the "pre-reacted" resin together with a tertiary amine catalyst and water as a blowing agent, the polymerization proceeds slowly enough to provide a stable foam body.

  19. Electron beam curing polyurethane acrylate oligomer in air

    International Nuclear Information System (INIS)

    Zhu, Zhenkang; Chen, Xing; Zhou, Jichun; Ma, Zue-Teh

    1988-01-01

    It has been found according to our synthesis that a novel kind of polyurethane acrylate oligomer can be cured by electron beam in the presence of oxygen, even at normal atomospheric levels, without any additives. Irradiation of the oligomer with substantially complete cure to a solid non-tacky state is quite remarkable. It has the same gel content (90 %) in air as in nitrogen at dose of 33 kGy. Double bond conversion of the oligomer is about 50 % by I.R. (author)

  20. Investigation of Industrial Polyurethane Foams Modified with Antimicrobial Copper Nanoparticles

    Directory of Open Access Journals (Sweden)

    Maria Chiara Sportelli

    2016-07-01

    Full Text Available Antimicrobial copper nanoparticles (CuNPs were electrosynthetized and applied to the controlled impregnation of industrial polyurethane foams used as padding in the textile production or as filters for air conditioning systems. CuNP-modified materials were investigated and characterized morphologically and spectroscopically, by means of Transmission Electron Microscopy (TEM, and X-ray Photoelectron Spectroscopy (XPS. The release of copper ions in solution was studied by Electro-Thermal Atomic Absorption Spectroscopy (ETAAS. Finally, the antimicrobial activity of freshly prepared, as well as aged samples—stored for two months—was demonstrated towards different target microorganisms.