WorldWideScience

Sample records for narrowly celebratory versions

  1. One-step green route to narrowly dispersed copper nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Wu Chunwei; Mosher, Brian P.; Zeng Taofang [North Carolina State University, Mechanical and Aerospace Engineering (United States)], E-mail: tzeng2@unity.ncsu.edu

    2006-12-15

    We report a total 'green' chemical method in aqueous solution for synthesizing stable narrowly distributed copper nanoparticles with average diameter less than 5 nm in the presence of Polyvinylpyrrolidone (PVP) as a stabilizer and without any inert gas protection. In our synthesis route, ascorbic acid, natural vitamin C (VC), an excellent oxygen scavenger, acts as both reducing agent and antioxidant, to reduce the metallic ion precursor, and to effectively prevent the common oxidation process of the newborn pure copper nanoclusters.

  2. Narrowly versus Broadly Defined Autism Spectrum Disorders: Differences in Pre-and Perinatal Risk Factors

    Science.gov (United States)

    Visser, Janne C.; Rommelse, Nanda; Vink, Lianne; Schrieken, Margo; Oosterling, Iris J.; Gaag, Rutger J.; Buitelaar, Jan K.

    2014-01-01

    This study examined the differential contribution of pre-and perinatal risks in narrowly versus broadly defined autism spectrum disorder (ASD) and across core symptom domains, IQ and co-morbid problems. Children with a DSM-IV diagnosis of autistic disorder (AD) (n = 121) or pervasive developmental disorder not otherwise specified (PDD-NOS)…

  3. Adjustment of Weed Hoeing to Narrowly Spaced Cereals

    Directory of Open Access Journals (Sweden)

    Jannis Machleb

    2018-04-01

    Full Text Available Weed hoeing can be successfully performed in wide row crops, such as sugar beet, maize, soybean and wide spaced cereals. However, little experience is available for hoeing in narrow cereal row spaces below 200 mm. Yet, mechanical weed control can pose an alternative to herbicide applications by reducing the herbicide resistant populations present in the field. In this experiment, it was investigated whether hoeing is feasible in cereals with 150 and 125 mm row spacings. The trial was set up at two locations (Ihinger Hof and Kleinhohenheim in southwest Germany. Three different conventional hoeing sweeps, a goosefoot sweep, a no-till sweep and a down-cut side knife were adjusted to the small row widths, and hoeing was performed once with a tractor and a standard hoeing frame which was guided by a second human operator. The average grain yield, crop and weed biomass, and weed control efficacy of each treatment were recorded. The goosefoot and no-till sweep were tested at driving speeds of 4 and 6 km·h−1. The down-cut side knife was applied at 4 km·h−1. The results indicate that hoeing caused no yield decrease in comparison to a conventional herbicide application or manual weeding. The highest yield with a mechanical treatment was recorded for the no-till sweeps at both trial locations. Hoeing was performed successfully in narrowly spaced cereals of 150 and 125 mm, and the weed control efficacy of the mechanical treatments ranged from 50.9% at Kleinhohenheim to 89.1% at Ihinger Hof. Future experiments are going to focus on more distinct driving speeds ranging from 2 to 10 km·h−1 and performing more than one pass with the hoe. Additionally, combining the mechanical weeding tools with a camera-steered hoeing frame could increase accuracy, allow for higher working speeds and substitute the second human operator guiding the hoe.

  4. Celebratory Cakes

    Science.gov (United States)

    Mahoney, Ellen

    2012-01-01

    Cakes are no longer the simple desserts they once were. The cake has evolved into an elaborate, sculptural form that represents a special occasion. Sculptural cake forms have become expressive designs using three-dimensional shapes, an array of surface textures, and a range of colors. The use of cakes in the artwork of David Gilhooly, Wayne…

  5. Version pressure feedback mechanisms for speculative versioning caches

    Science.gov (United States)

    Eichenberger, Alexandre E.; Gara, Alan; O& #x27; Brien, Kathryn M.; Ohmacht, Martin; Zhuang, Xiaotong

    2013-03-12

    Mechanisms are provided for controlling version pressure on a speculative versioning cache. Raw version pressure data is collected based on one or more threads accessing cache lines of the speculative versioning cache. One or more statistical measures of version pressure are generated based on the collected raw version pressure data. A determination is made as to whether one or more modifications to an operation of a data processing system are to be performed based on the one or more statistical measures of version pressure, the one or more modifications affecting version pressure exerted on the speculative versioning cache. An operation of the data processing system is modified based on the one or more determined modifications, in response to a determination that one or more modifications to the operation of the data processing system are to be performed, to affect the version pressure exerted on the speculative versioning cache.

  6. [External cephalic version].

    Science.gov (United States)

    Navarro-Santana, B; Duarez-Coronado, M; Plaza-Arranz, J

    2016-08-01

    To analyze the rate of successful external cephalic versions in our center and caesarean sections that would be avoided with the use of external cephalic versions. From January 2012 to March 2016 external cephalic versions carried out at our center, which were a total of 52. We collected data about female age, gestational age at the time of the external cephalic version, maternal body mass index (BMI), fetal variety and situation, fetal weight, parity, location of the placenta, amniotic fluid index (ILA), tocolysis, analgesia, and newborn weight at birth, minor adverse effects (dizziness, hypotension and maternal pain) and major adverse effects (tachycardia, bradycardia, decelerations and emergency cesarean section). 45% of the versions were unsuccessful and 55% were successful. The percentage of successful vaginal delivery in versions was 84% (4% were instrumental) and 15% of caesarean sections. With respect to the variables studied, only significant differences in birth weight were found; suggesting that birth weight it is related to the outcome of external cephalic version. Probably we did not find significant differences due to the number of patients studied. For women with breech presentation, we recommend external cephalic version before the expectant management or performing a cesarean section. The external cephalic version increases the proportion of fetuses in cephalic presentation and also decreases the rate of caesarean sections.

  7. Global Precipitation Climatology Project (GPCP) - Monthly, Version 2.2 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Version 2.2 of the dataset has been superseded by a newer version. Users should not use version 2.2 except in rare cases (e.g., when reproducing previous studies...

  8. Global Historical Climatology Network (GHCN), Version 1 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note, this dataset has been superseded by a newer version (see below). Users should not use this version except in rare cases (e.g., when reproducing previous...

  9. Global Historical Climatology Network - Daily (GHCN-Daily), Version 2 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note, this dataset has been superseded by a newer version (see below). Users should not use this version except in rare cases (e.g., when reproducing previous...

  10. NCDC International Best Track Archive for Climate Stewardship (IBTrACS) Project, Version 2 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Version 2 of the dataset has been superseded by a newer version. Users should not use version 2 except in rare cases (e.g., when reproducing previous studies that...

  11. NCDC International Best Track Archive for Climate Stewardship (IBTrACS) Project, Version 1 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Version 1 of the dataset has been superseded by a newer version. Users should not use version 1 except in rare cases (e.g., when reproducing previous studies that...

  12. Versioning Complex Data

    Energy Technology Data Exchange (ETDEWEB)

    Macduff, Matt C.; Lee, Benno; Beus, Sherman J.

    2014-06-29

    Using the history of ARM data files, we designed and demonstrated a data versioning paradigm that is feasible. Assigning versions to sets of files that are modified with some special assumptions and domain specific rules was effective in the case of ARM data, which has more than 5000 datastreams and 500TB of data.

  13. The Unified Extensional Versioning Model

    DEFF Research Database (Denmark)

    Asklund, U.; Bendix, Lars Gotfred; Christensen, H. B.

    1999-01-01

    Versioning of components in a system is a well-researched field where various adequate techniques have already been established. In this paper, we look at how versioning can be extended to cover also the structural aspects of a system. There exist two basic techniques for versioning - intentional...

  14. Assessment of radionuclide databases in CAP88 mainframe version 1.0 and Windows-based version 3.0.

    Science.gov (United States)

    LaBone, Elizabeth D; Farfán, Eduardo B; Lee, Patricia L; Jannik, G Timothy; Donnelly, Elizabeth H; Foley, Trevor Q

    2009-09-01

    In this study the radionuclide databases for two versions of the Clean Air Act Assessment Package-1988 (CAP88) computer model were assessed in detail. CAP88 estimates radiation dose and the risk of health effects to human populations from radionuclide emissions to air. This program is used by several U.S. Department of Energy (DOE) facilities to comply with National Emission Standards for Hazardous Air Pollutants regulations. CAP88 Mainframe, referred to as version 1.0 on the U.S. Environmental Protection Agency Web site (http://www.epa.gov/radiation/assessment/CAP88/), was the very first CAP88 version released in 1988. Some DOE facilities including the Savannah River Site still employ this version (1.0) while others use the more user-friendly personal computer Windows-based version 3.0 released in December 2007. Version 1.0 uses the program RADRISK based on International Commission on Radiological Protection Publication 30 as its radionuclide database. Version 3.0 uses half-life, dose, and risk factor values based on Federal Guidance Report 13. Differences in these values could cause different results for the same input exposure data (same scenario), depending on which version of CAP88 is used. Consequently, the differences between the two versions are being assessed in detail at Savannah River National Laboratory. The version 1.0 and 3.0 database files contain 496 and 838 radionuclides, respectively, and though one would expect the newer version to include all the 496 radionuclides, 35 radionuclides are listed in version 1.0 that are not included in version 3.0. The majority of these has either extremely short or long half-lives or is no longer in production; however, some of the short-lived radionuclides might produce progeny of great interest at DOE sites. In addition, 122 radionuclides were found to have different half-lives in the two versions, with 21 over 3 percent different and 12 over 10 percent different.

  15. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (UNIX VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the

  16. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (MACINTOSH VERSION)

    Science.gov (United States)

    Riley, G.

    1994-01-01

    COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the

  17. NETS - A NEURAL NETWORK DEVELOPMENT TOOL, VERSION 3.0 (MACINTOSH VERSION)

    Science.gov (United States)

    Phillips, T. A.

    1994-01-01

    allows the user to generate C code to implement the network loaded into the system. This permits the placement of networks as components, or subroutines, in other systems. In short, once a network performs satisfactorily, the Generate C Code option provides the means for creating a program separate from NETS to run the network. Other features: files may be stored in binary or ASCII format; multiple input propagation is permitted; bias values may be included; capability to scale data without writing scaling code; quick interactive testing of network from the main menu; and several options that allow the user to manipulate learning efficiency. NETS is written in ANSI standard C language to be machine independent. The Macintosh version (MSC-22108) includes code for both a graphical user interface version and a command line interface version. The machine independent version (MSC-21588) only includes code for the command line interface version of NETS 3.0. The Macintosh version requires a Macintosh II series computer and has been successfully implemented under System 7. Four executables are included on these diskettes, two for floating point operations and two for integer arithmetic. It requires Think C 5.0 to compile. A minimum of 1Mb of RAM is required for execution. Sample input files and executables for both the command line version and the Macintosh user interface version are provided on the distribution medium. The Macintosh version is available on a set of three 3.5 inch 800K Macintosh format diskettes. The machine independent version has been successfully implemented on an IBM PC series compatible running MS-DOS, a DEC VAX running VMS, a SunIPC running SunOS, and a CRAY Y-MP running UNICOS. Two executables for the IBM PC version are included on the MS-DOS distribution media, one compiled for floating point operations and one for integer arithmetic. The machine independent version is available on a set of three 5.25 inch 360K MS-DOS format diskettes (standard

  18. Verification of RESRAD-RDD. (Version 2.01)

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Jing-Jy [Argonne National Lab. (ANL), Argonne, IL (United States); Flood, Paul E. [Argonne National Lab. (ANL), Argonne, IL (United States); LePoire, David [Argonne National Lab. (ANL), Argonne, IL (United States); Kamboj, Sunita [Argonne National Lab. (ANL), Argonne, IL (United States); Yu, Charley [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-09-01

    In this report, the results generated by RESRAD-RDD version 2.01 are compared with those produced by RESRAD-RDD version 1.7 for different scenarios with different sets of input parameters. RESRAD-RDD version 1.7 is spreadsheet-driven, performing calculations with Microsoft Excel spreadsheets. RESRAD-RDD version 2.01 revamped version 1.7 by using command-driven programs designed with Visual Basic.NET to direct calculations with data saved in Microsoft Access database, and re-facing the graphical user interface (GUI) to provide more flexibility and choices in guideline derivation. Because version 1.7 and version 2.01 perform the same calculations, the comparison of their results serves as verification of both versions. The verification covered calculation results for 11 radionuclides included in both versions: Am-241, Cf-252, Cm-244, Co-60, Cs-137, Ir-192, Po-210, Pu-238, Pu-239, Ra-226, and Sr-90. At first, all nuclidespecific data used in both versions were compared to ensure that they are identical. Then generic operational guidelines and measurement-based radiation doses or stay times associated with a specific operational guideline group were calculated with both versions using different sets of input parameters, and the results obtained with the same set of input parameters were compared. A total of 12 sets of input parameters were used for the verification, and the comparison was performed for each operational guideline group, from A to G, sequentially. The verification shows that RESRAD-RDD version 1.7 and RESRAD-RDD version 2.01 generate almost identical results; the slight differences could be attributed to differences in numerical precision with Microsoft Excel and Visual Basic.NET. RESRAD-RDD version 2.01 allows the selection of different units for use in reporting calculation results. The results of SI units were obtained and compared with the base results (in traditional units) used for comparison with version 1.7. The comparison shows that RESRAD

  19. HANFORD TANK WASTE OPERATIONS SIMULATOR VERSION DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    ALLEN, G.K.

    2003-01-01

    This document describes the software version controls established for the Hanford Tank Waste Operations Simulator (HTWOS). It defines: the methods employed to control the configuration of HTWOS; the version of each of the 26 separate modules for the version 1.0 of HTWOS; the numbering rules for incrementing the version number of each module; and a requirement to include module version numbers in each case results documentation. Version 1.0 of HTWOS is the first version under formal software version control. HTWOS contains separate revision numbers for each of its 26 modules. Individual module version numbers do not reflect the major release HTWOS configured version number

  20. The comparison of CAP88-PC version 2.0 versus CAP88-PC version 1.0

    International Nuclear Information System (INIS)

    Yakubovich, B.A.; Klee, K.O.; Palmer, C.R.; Spotts, P.B.

    1997-12-01

    40 CFR Part 61 (Subpart H of the NESHAP) requires DOE facilities to use approved sampling procedures, computer models, or other approved procedures when calculating Effective Dose Equivalent (EDE) values to members of the public. Currently version 1.0 of the approved computer model CAP88-PC is used to calculate EDE values. The DOE has upgraded the CAP88-PC software to version 2.0. This version provides simplified data entry, better printing characteristics, the use of a mouse, and other features. The DOE has developed and released version 2.0 for testing and comment. This new software is a WINDOWS based application that offers a new graphical user interface with new utilities for preparing and managing population and weather data, and several new decay chains. The program also allows the user to view results before printing. This document describes a test that confirmed CAP88-PC version 2.0 generates results comparable to the original version of the CAP88-PC program

  1. A comparison of the Space Station version of ASTROMAG with two free-flyer versions

    International Nuclear Information System (INIS)

    Green, M.A.

    1992-06-01

    This Report compares the Space Station version of ASTROMAG with free-flyer versions of ASTROMAG which could fly on an Atlas lla rocket and a Delta rocket. Launch with either free-flyer imposes severe weight limits on the magnet and its cryogenic system. Both versions of ASTROMAG magnet which fly on free-flying satellites do not have to be charged more than once during the mission. This permits one to simplify the charging system and the cryogenic system. The helium ll pump loop which supplies helium to the gas cooled electrical leads can be eliminated in both of the free-flyer versions of the ASTROMAG magnet. This report describes the superconducting dipole moment correction coils which are necessary for the magnet to operate on a free-flying satellite

  2. Versioning of printed products

    Science.gov (United States)

    Tuijn, Chris

    2005-01-01

    During the definition of a printed product in an MIS system, a lot of attention is paid to the production process. The MIS systems typically gather all process-related parameters at such a level of detail that they can determine what the exact cost will be to make a specific product. This information can then be used to make a quote for the customer. Considerably less attention is paid to the content of the products since this does not have an immediate impact on the production costs (assuming that the number of inks or plates is known in advance). The content management is typically carried out either by the prepress systems themselves or by dedicated workflow servers uniting all people that contribute to the manufacturing of a printed product. Special care must be taken when considering versioned products. With versioned products we here mean distinct products that have a number of pages or page layers in common. Typical examples are comic books that have to be printed in different languages. In this case, the color plates can be shared over the different versions and the black plate will be different. Other examples are nation-wide magazines or newspapers that have an area with regional pages or advertising leaflets in different languages or currencies. When considering versioned products, the content will become an important cost factor. First of all, the content management (and associated proofing and approval cycles) becomes much more complex and, therefore, the risk that mistakes will be made increases considerably. Secondly, the real production costs are very much content-dependent because the content will determine whether plates can be shared across different versions or not and how many press runs will be needed. In this paper, we will present a way to manage different versions of a printed product. First, we will introduce a data model for version management. Next, we will show how the content of the different versions can be supplied by the customer

  3. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (IBM PC VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the

  4. NETS - A NEURAL NETWORK DEVELOPMENT TOOL, VERSION 3.0 (MACHINE INDEPENDENT VERSION)

    Science.gov (United States)

    Baffes, P. T.

    1994-01-01

    allows the user to generate C code to implement the network loaded into the system. This permits the placement of networks as components, or subroutines, in other systems. In short, once a network performs satisfactorily, the Generate C Code option provides the means for creating a program separate from NETS to run the network. Other features: files may be stored in binary or ASCII format; multiple input propagation is permitted; bias values may be included; capability to scale data without writing scaling code; quick interactive testing of network from the main menu; and several options that allow the user to manipulate learning efficiency. NETS is written in ANSI standard C language to be machine independent. The Macintosh version (MSC-22108) includes code for both a graphical user interface version and a command line interface version. The machine independent version (MSC-21588) only includes code for the command line interface version of NETS 3.0. The Macintosh version requires a Macintosh II series computer and has been successfully implemented under System 7. Four executables are included on these diskettes, two for floating point operations and two for integer arithmetic. It requires Think C 5.0 to compile. A minimum of 1Mb of RAM is required for execution. Sample input files and executables for both the command line version and the Macintosh user interface version are provided on the distribution medium. The Macintosh version is available on a set of three 3.5 inch 800K Macintosh format diskettes. The machine independent version has been successfully implemented on an IBM PC series compatible running MS-DOS, a DEC VAX running VMS, a SunIPC running SunOS, and a CRAY Y-MP running UNICOS. Two executables for the IBM PC version are included on the MS-DOS distribution media, one compiled for floating point operations and one for integer arithmetic. The machine independent version is available on a set of three 5.25 inch 360K MS-DOS format diskettes (standard

  5. NOAA Climate Data Record (CDR) of Ocean Heat Fluxes, Version 1.0 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note, this dataset has been superseded by a newer version (see below). Users should not use this version except in rare cases (e.g., when reproducing previous...

  6. GENII Version 2 Users’ Guide

    Energy Technology Data Exchange (ETDEWEB)

    Napier, Bruce A.

    2004-03-08

    The GENII Version 2 computer code was developed for the Environmental Protection Agency (EPA) at Pacific Northwest National Laboratory (PNNL) to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) and the radiological risk estimating procedures of Federal Guidance Report 13 into updated versions of existing environmental pathway analysis models. The resulting environmental dosimetry computer codes are compiled in the GENII Environmental Dosimetry System. The GENII system was developed to provide a state-of-the-art, technically peer-reviewed, documented set of programs for calculating radiation dose and risk from radionuclides released to the environment. The codes were designed with the flexibility to accommodate input parameters for a wide variety of generic sites. Operation of a new version of the codes, GENII Version 2, is described in this report. Two versions of the GENII Version 2 code system are available, a full-featured version and a version specifically designed for demonstrating compliance with the dose limits specified in 40 CFR 61.93(a), the National Emission Standards for Hazardous Air Pollutants (NESHAPS) for radionuclides. The only differences lie in the limitation of the capabilities of the user to change specific parameters in the NESHAPS version. This report describes the data entry, accomplished via interactive, menu-driven user interfaces. Default exposure and consumption parameters are provided for both the average (population) and maximum individual; however, these may be modified by the user. Source term information may be entered as radionuclide release quantities for transport scenarios, or as basic radionuclide concentrations in environmental media (air, water, soil). For input of basic or derived concentrations, decay of parent radionuclides and ingrowth of radioactive decay products prior to the start of the exposure scenario may be considered. A single code run can

  7. A constructive version of AIP revisited

    NARCIS (Netherlands)

    Barros, A.; Hou, T.

    2008-01-01

    In this paper, we review a constructive version of the Approximation Induction Principle. This version states that bisimilarity of regular processes can be decided by observing only a part of their behaviour. We use this constructive version to formulate a complete inference system for the Algebra

  8. Model-based version management system framework

    International Nuclear Information System (INIS)

    Mehmood, W.

    2016-01-01

    In this paper we present a model-based version management system. Version Management System (VMS) a branch of software configuration management (SCM) aims to provide a controlling mechanism for evolution of software artifacts created during software development process. Controlling the evolution requires many activities to perform, such as, construction and creation of versions, identification of differences between versions, conflict detection and merging. Traditional VMS systems are file-based and consider software systems as a set of text files. File based VMS systems are not adequate for performing software configuration management activities such as, version control on software artifacts produced in earlier phases of the software life cycle. New challenges of model differencing, merge, and evolution control arise while using models as central artifact. The goal of this work is to present a generic framework model-based VMS which can be used to overcome the problem of tradition file-based VMS systems and provide model versioning services. (author)

  9. Determining Optimal Decision Version

    Directory of Open Access Journals (Sweden)

    Olga Ioana Amariei

    2014-06-01

    Full Text Available In this paper we start from the calculation of the product cost, applying the method of calculating the cost of hour- machine (THM, on each of the three cutting machines, namely: the cutting machine with plasma, the combined cutting machine (plasma and water jet and the cutting machine with a water jet. Following the calculation of cost and taking into account the precision of manufacturing of each machine, as well as the quality of the processed surface, the optimal decisional version needs to be determined regarding the product manufacturing. To determine the optimal decisional version, we resort firstly to calculating the optimal version on each criterion, and then overall using multiattribute decision methods.

  10. Detailed analysis of the Japanese version of the Rapid Dementia Screening Test, revised version.

    Science.gov (United States)

    Moriyama, Yasushi; Yoshino, Aihide; Muramatsu, Taro; Mimura, Masaru

    2017-11-01

    The number-transcoding task on the Japanese version of the Rapid Dementia Screening Test (RDST-J) requires mutual conversion between Arabic and Chinese numerals (209 to , 4054 to , to 681, to 2027). In this task, question and answer styles of Chinese numerals are written horizontally. We investigated the impact of changing the task so that Chinese numerals are written vertically. Subjects were 211 patients with very mild to severe Alzheimer's disease and 42 normal controls. Mini-Mental State Examination scores ranged from 26 to 12, and Clinical Dementia Rating scores ranged from 0.5 to 3. Scores of all four subtasks of the transcoding task significantly improved in the revised version compared with the original version. The sensitivity and specificity of total scores ≥9 on the RDST-J original and revised versions for discriminating between controls and subjects with Clinical Dementia Rating scores of 0.5 were 63.8% and 76.6% on the original and 60.1% and 85.8% on revised version. The revised RDST-J total score had low sensitivity and high specificity compared with the original RDST-J for discriminating subjects with Clinical Dementia Rating scores of 0.5 from controls. © 2017 Japanese Psychogeriatric Society.

  11. Version 2 of RSXMULTI

    International Nuclear Information System (INIS)

    Heinicke, P.; Berg, D.; Constanta-Fanourakis, P.; Quigg, E.K.

    1985-01-01

    MULTI is a general purpose, high speed, high energy physics interface to data acquisition and data investigation system that runs on PDP-11 and VAX architecture. This paper describes the latest version of MULTI, which runs under RSX-11M version 4.1 and supports a modular approach to the separate tasks that interface to it, allowing the same system to be used in single CPU test beam experiments as well as multiple interconnected CPU, large scale experiments. MULTI uses CAMAC (IEE-583) for control and monitoring of an experiment, and is written in FORTRAN-77 and assembler. The design of this version, which simplified the interface between tasks, and eliminated the need for a hard to maintain homegrown I/O system is also discussed

  12. CLIPS 6.0 - C LANGUAGE INTEGRATED PRODUCTION SYSTEM, VERSION 6.0 (DEC VAX VMS VERSION)

    Science.gov (United States)

    Donnell, B.

    1994-01-01

    COOL (that is, a rule can pattern match on objects created using COOL). CLIPS 6.0 provides the capability to define functions, overloaded functions, and global variables interactively. In addition, CLIPS can be embedded within procedural code, called as a subroutine, and integrated with languages such as C, FORTRAN and Ada. CLIPS can be easily extended by a user through the use of several well-defined protocols. CLIPS provides several delivery options for programs including the ability to generate stand alone executables or to load programs from text or binary files. CLIPS 6.0 provides support for the modular development and execution of knowledge bases with the defmodule construct. CLIPS modules allow a set of constructs to be grouped together such that explicit control can be maintained over restricting the access of the constructs by other modules. This type of control is similar to global and local scoping used in languages such as C or Ada. By restricting access to deftemplate and defclass constructs, modules can function as blackboards, permitting only certain facts and instances to be seen by other modules. Modules are also used by rules to provide execution control. The CRSV (Cross-Reference, Style, and Verification) utility included with previous version of CLIPS is no longer supported. The capabilities provided by this tool are now available directly within CLIPS 6.0 to aid in the development, debugging, and verification of large rule bases. COSMIC offers four distribution versions of CLIPS 6.0: UNIX (MSC-22433), VMS (MSC-22434), MACINTOSH (MSC-22429), and IBM PC (MSC-22430). Executable files, source code, utilities, documentation, and examples are included on the program media. All distribution versions include identical source code for the command line version of CLIPS 6.0. This source code should compile on any platform with an ANSI C compiler. Each distribution version of CLIPS 6.0, except that for the Macintosh platform, includes an executable for the

  13. NOAA Climate Data Record (CDR) of Sea Surface Temperature - WHOI, Version 1.0 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note, this dataset has been superseded by a newer version (see below). Users should not use this version except in rare cases (e.g., when reproducing previous...

  14. NOAA Climate Data Record (CDR) of Ocean Near Surface Atmospheric Properties, Version 1 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note, this dataset has been superseded by a newer version (see below). Users should not use this version except in rare cases (e.g., when reproducing previous...

  15. Reliability and validity of the Japanese version of the Resilience Scale and its short version

    Directory of Open Access Journals (Sweden)

    Kondo Maki

    2010-11-01

    Full Text Available Abstract Background The clinical relevance of resilience has received considerable attention in recent years. The aim of this study is to demonstrate the reliability and validity of the Japanese version of the Resilience Scale (RS and short version of the RS (RS-14. Findings The original English version of RS was translated to Japanese and the Japanese version was confirmed by back-translation. Participants were 430 nursing and university psychology students. The RS, Center for Epidemiologic Studies Depression Scale (CES-D, Rosenberg Self-Esteem Scale (RSES, Social Support Questionnaire (SSQ, Perceived Stress Scale (PSS, and Sheehan Disability Scale (SDS were administered. Internal consistency, convergent validity and factor loadings were assessed at initial assessment. Test-retest reliability was assessed using data collected from 107 students at 3 months after baseline. Mean score on the RS was 111.19. Cronbach's alpha coefficients for the RS and RS-14 were 0.90 and 0.88, respectively. The test-retest correlation coefficients for the RS and RS-14 were 0.83 and 0.84, respectively. Both the RS and RS-14 were negatively correlated with the CES-D and SDS, and positively correlated with the RSES, SSQ and PSS (all p Conclusions This study demonstrates that the Japanese version of RS has psychometric properties with high degrees of internal consistency, high test-retest reliability, and relatively low concurrent validity. RS-14 was equivalent to the RS in internal consistency, test-retest reliability, and concurrent validity. Low scores on the RS, a positive correlation between the RS and perceived stress, and a relatively low correlation between the RS and depressive symptoms in this study suggest that validity of the Japanese version of the RS might be relatively low compared with the original English version.

  16. Montage Version 3.0

    Science.gov (United States)

    Jacob, Joseph; Katz, Daniel; Prince, Thomas; Berriman, Graham; Good, John; Laity, Anastasia

    2006-01-01

    The final version (3.0) of the Montage software has been released. To recapitulate from previous NASA Tech Briefs articles about Montage: This software generates custom, science-grade mosaics of astronomical images on demand from input files that comply with the Flexible Image Transport System (FITS) standard and contain image data registered on projections that comply with the World Coordinate System (WCS) standards. This software can be executed on single-processor computers, multi-processor computers, and such networks of geographically dispersed computers as the National Science Foundation s TeraGrid or NASA s Information Power Grid. The primary advantage of running Montage in a grid environment is that computations can be done on a remote supercomputer for efficiency. Multiple computers at different sites can be used for different parts of a computation a significant advantage in cases of computations for large mosaics that demand more processor time than is available at any one site. Version 3.0 incorporates several improvements over prior versions. The most significant improvement is that this version is accessible to scientists located anywhere, through operational Web services that provide access to data from several large astronomical surveys and construct mosaics on either local workstations or remote computational grids as needed.

  17. Fetomaternal hemorrhage during external cephalic version.

    Science.gov (United States)

    Boucher, Marc; Marquette, Gerald P; Varin, Jocelyne; Champagne, Josette; Bujold, Emmanuel

    2008-07-01

    To estimate the frequency and volume of fetomaternal hemorrhage during external cephalic version for term breech singleton fetuses and to identify risk factors involved with this complication. A prospective observational study was performed including all patients undergoing a trial of external cephalic version for a breech presentation of at least 36 weeks of gestation between 1987 and 2001 in our center. A search for fetal erythrocytes using the standard Kleihauer-Betke test was obtained before and after each external cephalic version. The frequency and volume of fetomaternal hemorrhage were calculated. Putative risk factors for fetomaternal hemorrhage were evaluated by chi(2) test and Mann-Whitney U test. A Kleihauer-Betke test result was available before and after 1,311 trials of external cephalic version. The Kleihauer-Betke test was positive in 67 (5.1%) before the procedure. Of the 1,244 women with a negative Kleihauer-Betke test before external cephalic version, 30 (2.4%) had a positive Kleihauer-Betke test after the procedure. Ten (0.8%) had an estimated fetomaternal hemorrhage greater than 1 mL, and one (0.08%) had an estimated fetomaternal hemorrhage greater than 30 mL. The risk of fetomaternal hemorrhage was not influenced by parity, gestational age, body mass index, number of attempts at version, placental location, or amniotic fluid index. The risk of detectable fetomaternal hemorrhage during external cephalic version was 2.4%, with fetomaternal hemorrhage more than 30 mL in less than 0.1% of cases. These data suggest that the performance of a Kleihauer-Betke test is unwarranted in uneventful external cephalic version and that in Rh-negative women, no further Rh immune globulin is necessary other than the routine 300-microgram dose at 28 weeks of gestation and postpartum. II.

  18. Progress Towards AIRS Science Team Version-7 at SRT

    Science.gov (United States)

    Susskind, Joel; Blaisdell, John; Iredell, Lena; Kouvaris, Louis

    2016-01-01

    The AIRS Science Team Version-6 retrieval algorithm is currently producing level-3 Climate Data Records (CDRs) from AIRS that have been proven useful to scientists in understanding climate processes. CDRs are gridded level-3 products which include all cases passing AIRS Climate QC. SRT has made significant further improvements to AIRS Version-6. At the last Science Team Meeting, we described results using SRT AIRS Version-6.22. SRT Version-6.22 is now an official build at JPL called 6.2.4. Version-6.22 results are significantly improved compared to Version-6, especially with regard to water vapor and ozone profiles. We have adapted AIRS Version-6.22 to run with CrIS/ATMS, at the Sounder SIPS which processed CrIS/ATMS data for August 2014. JPL AIRS Version-6.22 uses the Version-6 AIRS tuning coefficients. AIRS Version-6.22 has at least two limitations which must be improved before finalization of Version-7: Version-6.22 total O3 has spurious high values in the presence of Saharan dust over the ocean; and Version-6.22 retrieved upper stratospheric temperatures are very poor in polar winter. SRT Version-6.28 addresses the first concern. John Blaisdell ran the analog of AIRS Version-6.28 in his own sandbox at JPL for the 14th and 15th of every month in 2014 and all of July and October for 2014. AIRS Version-6.28a is hot off the presses and addresses the second concern.

  19. Intercomparison of ILAS-II version 1.4 and version 2 target parameters with MIPAS-Envisat measurements

    Directory of Open Access Journals (Sweden)

    A. Griesfeller

    2008-02-01

    Full Text Available This paper assesses the mean differences between the two ILAS-II data versions (1.4 and 2 by comparing them with MIPAS measurements made between May and October 2003. For comparison with ILAS-II results, MIPAS data processed at the Institut für Meteorologie und Klimaforschung, Karlsruhe, Germany (IMK in cooperation with the Instituto de Astrofísica de Andalucía (IAA in Granada, Spain, were used. The coincidence criteria of ±300 km in space and ±12 h in time for H2O, N2O, and CH4 and the coincidence criteria of ±300 km in space and ±6 h in time for ClONO2, O3, and HNO3 were used. The ILAS-II data were separated into sunrise (= Northern Hemisphere and sunset (= Southern Hemisphere. For the sunrise data, a clear improvement from version 1.4 to version 2 was observed for H2O, CH4, ClONO2, and O3. In particular, the ILAS-II version 1.4 mixing ratios of H2O and CH4 were unrealistically small, and those of ClONO2 above altitudes of 30 km unrealistically large. For N2O and HNO3, there were no large differences between the two versions. Contrary to the Northern Hemisphere, where some exceptional profiles deviated significantly from known climatology, no such outlying profiles were found in the Southern Hemisphere for both versions. Generally, the ILAS-II version 2 data were in better agreement with the MIPAS data than the version 1.4, and are recommended for quantitative analysis in the stratosphere. For H2O data in the Southern Hemisphere, further data quality evaluation is necessary.

  20. Development of a Chinese version of the Oswestry Disability Index version 2.1.

    Science.gov (United States)

    Lue, Yi-Jing; Hsieh, Ching-Lin; Huang, Mao-Hsiung; Lin, Gau-Tyan; Lu, Yen-Mou

    2008-10-01

    Cross-cultural adaptation and cross-sectional psychometric testing in a convenience sample of patients with low back pain. To translate and culturally adapt the Oswestry Disability Index version 2.1 (ODI 2.1) into a Mandarin Chinese version and to assess its reliability and validity. The Chinese ODI 2.1 has not been developed and validated. The ODI 2.1 was translated and culturally adapted to the Chinese version. The validity of the translated Chinese version was assessed by examining the relationship between the ODI and other well-known measures. Test-retest reliability was examined in 52 of these patients, who completed a second questionnaire within 1 week. Internal consistency of the ODI 2.1 was excellent with Cronbach's alpha = 0.903. The intraclass correlation coefficient of test-retest reliability was 0.89. The minimal detectable change was 12.8. The convergent validity of the Chinese ODI is supported by its high correlation with other physical functional status measures (Roland Morris Disability Questionnaire and SF-36 physical functioning subscale, r = 0.76 and -0.75, respectively), and moderate correlation with other measures (Visual Analogue Scale, r = 0.68) and certain SF-36 subscales (role-physical, bodily pain, and social functioning, r range: -0.49 to -0.57). As expected, the ODI was least correlated with nonfunctional measures (SF-36 mental subscale and role-emotional subscale, r = -0.25 and -0.33, respectively). The results of this study indicate that the Chinese version of the ODI 2.1 is a reliable and valid instrument for the measurement of functional status in patients with low back pain.

  1. ELIPGRID-PC: Upgraded version

    International Nuclear Information System (INIS)

    Davidson, J.R.

    1995-12-01

    Evaluating the need for and the effectiveness of remedial cleanup at waste sites often includes finding average contaminant concentrations and identifying pockets of contamination called hot spots. The standard tool for calculating the probability of detecting pockets of contamination called hot spots has been the ELIPGRID code of singer and Wickman. The ELIPGRID-PC program has recently made this algorithm available for an IBM reg-sign personal computer (PC) or compatible. A new version of ELIPGRID-PC, incorporating Monte Carlo test results and simple graphics, is herein described. Various examples of how to use the program for both single and multiple hot spot cases are given. The code for an American National Standards Institute C version of the ELIPGRID algorithm is provided, and limitations and further work are noted. This version of ELIPGRID-PC reliably meets the goal of moving Singer's ELIPGRID algorithm to the PC

  2. Reliability and validity of the Japanese version of the Resilience Scale and its short version.

    Science.gov (United States)

    Nishi, Daisuke; Uehara, Ritei; Kondo, Maki; Matsuoka, Yutaka

    2010-11-17

    The clinical relevance of resilience has received considerable attention in recent years. The aim of this study is to demonstrate the reliability and validity of the Japanese version of the Resilience Scale (RS) and short version of the RS (RS-14). The original English version of RS was translated to Japanese and the Japanese version was confirmed by back-translation. Participants were 430 nursing and university psychology students. The RS, Center for Epidemiologic Studies Depression Scale (CES-D), Rosenberg Self-Esteem Scale (RSES), Social Support Questionnaire (SSQ), Perceived Stress Scale (PSS), and Sheehan Disability Scale (SDS) were administered. Internal consistency, convergent validity and factor loadings were assessed at initial assessment. Test-retest reliability was assessed using data collected from 107 students at 3 months after baseline. Mean score on the RS was 111.19. Cronbach's alpha coefficients for the RS and RS-14 were 0.90 and 0.88, respectively. The test-retest correlation coefficients for the RS and RS-14 were 0.83 and 0.84, respectively. Both the RS and RS-14 were negatively correlated with the CES-D and SDS, and positively correlated with the RSES, SSQ and PSS (all p reliability, and relatively low concurrent validity. RS-14 was equivalent to the RS in internal consistency, test-retest reliability, and concurrent validity. Low scores on the RS, a positive correlation between the RS and perceived stress, and a relatively low correlation between the RS and depressive symptoms in this study suggest that validity of the Japanese version of the RS might be relatively low compared with the original English version.

  3. Introducing external cephalic version in a Malaysian setting.

    Science.gov (United States)

    Yong, Stephen P Y

    2007-02-01

    To assess the outcome of external cephalic version for routine management of malpresenting foetuses at term. Prospective observational study. Tertiary teaching hospital, Malaysia. From September 2003 to June 2004, a study involving 41 pregnant women with malpresentation at term was undertaken. An external cephalic version protocol was implemented. Data were collected for identifying characteristics associated with success or failure of external cephalic version. Maternal and foetal outcome measures including success rate of external cephalic version, maternal and foetal complications, and characteristics associated with success or failure; engagement of presenting part, placental location, direction of version, attempts at version, use of intravenous tocolytic agent, eventual mode of delivery, Apgar scores, birth weights, and maternal satisfaction with the procedure. Data were available for 38 women. External cephalic version was successful in 63% of patients; the majority (75%) of whom achieved a vaginal delivery. Multiparity (odds ratio=34.0; 95% confidence interval, 0.67-1730) and high amniotic fluid index (4.9; 1.3-18.2) were associated with successful external cephalic version. Engagement of presenting part (odds ratio=0.0001; 95% confidence interval, 0.00001-0.001) and a need to resort to backward somersault (0.02; 0.00001-0.916) were associated with poor success rates. Emergency caesarean section rate for foetal distress directly resulting from external cephalic version was 8%, but there was no perinatal or maternal adverse outcome. The majority (74%) of women were satisfied with external cephalic version. External cephalic version has acceptable success rates. Multiparity, liquor volume, engagement of presenting part, and the need for backward somersault were strong predictors of outcome. External cephalic version is relatively safe, simple to learn and perform, and associated with maternal satisfaction. Modern obstetric units should routinely offer the

  4. External cephalic version-related risks: a meta-analysis.

    Science.gov (United States)

    Grootscholten, Kim; Kok, Marjolein; Oei, S Guid; Mol, Ben W J; van der Post, Joris A

    2008-11-01

    To systematically review the literature on external cephalic version-related complications and to assess if the outcome of a version attempt is related to complications. In March 2007 we searched MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials. Studies reporting on complications from an external cephalic version attempt for singleton breech pregnancies after 36 weeks of pregnancy were selected. We calculated odds ratios (ORs) from studies that reported both on complications as well as on the position of the fetus immediately after the procedure. We found 84 studies, reporting on 12,955 version attempts that reported on external cephalic version-related complications. The pooled complication rate was 6.1% (95% CI 4.7-7.8), 0.24% for serious complications (95% confidence interval [CI] 0.17-0.34) and 0.35% for emergency cesarean deliveries (95% CI 0.26-0.47). Complications were not related to external cephalic version outcome (OR 1.2 (95% CI 0.93-1.7). External cephalic version is a safe procedure. Complications are not related to the fetal position after external cephalic version.

  5. Inclusion in the Workplace - Text Version | NREL

    Science.gov (United States)

    Careers » Inclusion in the Workplace - Text Version Inclusion in the Workplace - Text Version This is the text version for the Inclusion: Leading by Example video. I'm Martin Keller. I'm the NREL of the laboratory. Another very important element in inclusion is diversity. Because if we have a

  6. Comparing two versions of the Karolinska Sleepiness Scale (KSS).

    Science.gov (United States)

    Miley, Anna Åkerstedt; Kecklund, Göran; Åkerstedt, Torbjörn

    2016-01-01

    The Karolinska Sleepiness Scale (KSS) is frequently used to study sleepiness in various contexts. However, it exists in two versions, one with labels on every other step (version A), and one with labels on every step (version B) on the 9-point scale. To date, there are no studies examining whether these versions can be used interchangeably. The two versions were here compared in a 24 hr wakefulness study of 12 adults. KSS ratings were obtained every hour, alternating version A and B. Results indicated that the two versions are highly correlated, do not have different response distributions on labeled and unlabeled steps, and that the distributions across all steps have a high level of correspondence (Kappa = 0.73). It was concluded that the two versions are quite similar.

  7. FORM version 4.0

    Science.gov (United States)

    Kuipers, J.; Ueda, T.; Vermaseren, J. A. M.; Vollinga, J.

    2013-05-01

    We present version 4.0 of the symbolic manipulation system FORM. The most important new features are manipulation of rational polynomials and the factorization of expressions. Many other new functions and commands are also added; some of them are very general, while others are designed for building specific high level packages, such as one for Gröbner bases. New is also the checkpoint facility, that allows for periodic backups during long calculations. Finally, FORM 4.0 has become available as open source under the GNU General Public License version 3. Program summaryProgram title: FORM. Catalogue identifier: AEOT_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEOT_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU General Public License, version 3 No. of lines in distributed program, including test data, etc.: 151599 No. of bytes in distributed program, including test data, etc.: 1 078 748 Distribution format: tar.gz Programming language: The FORM language. FORM itself is programmed in a mixture of C and C++. Computer: All. Operating system: UNIX, LINUX, Mac OS, Windows. Classification: 5. Nature of problem: FORM defines a symbolic manipulation language in which the emphasis lies on fast processing of very large formulas. It has been used successfully for many calculations in Quantum Field Theory and mathematics. In speed and size of formulas that can be handled it outperforms other systems typically by an order of magnitude. Special in this version: The version 4.0 contains many new features. Most important are factorization and rational arithmetic. The program has also become open source under the GPL. The code in CPC is for reference. You are encouraged to upload the most recent sources from www.nikhef.nl/form/formcvs.php because of frequent bug fixes. Solution method: See "Nature of Problem", above. Additional comments: NOTE: The code in CPC is for reference. You are encouraged

  8. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (MACINTOSH VERSION)

    Science.gov (United States)

    Culbert, C.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  9. NOAA Climate Data Record (CDR) of AVHRR Daily and Monthly Aerosol Optical Thickness over Global Oceans, Version 2.0 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Version 2 of the dataset has been superseded by a newer version. Users should not use version 2 except in rare cases (e.g., when reproducing previous studies that...

  10. NOAA Climate Data Record (CDR) of AVHRR Daily and Monthly Aerosol Optical Thickness over Global Oceans, Version 1.0 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Version 1 of the dataset has been superseded by a newer version. Users should not use version 1 except in rare cases (e.g., when reproducing previous studies that...

  11. Schema Versioning for Multitemporal Relational Databases.

    Science.gov (United States)

    De Castro, Cristina; Grandi, Fabio; Scalas, Maria Rita

    1997-01-01

    Investigates new design options for extended schema versioning support for multitemporal relational databases. Discusses the improved functionalities they may provide. Outlines options and basic motivations for the new design solutions, as well as techniques for the management of proposed schema versioning solutions, includes algorithms and…

  12. Moxibustion for Cephalic Version of Breech Presentation.

    Science.gov (United States)

    Schlaeger, Judith M; Stoffel, Cynthia L; Bussell, Jeanie L; Cai, Hui Yan; Takayama, Miho; Yajima, Hiroyoshi; Takakura, Nobuari

    2018-05-01

    Moxibustion, a form of traditional Chinese medicine (TCM), is the burning of the herb moxa (Folium Artemisiae argyi or mugwort) over acupuncture points. It is often used in China to facilitate cephalic version of breech presentation. This article reviews the history, philosophy, therapeutic use, possible mechanisms of action, and literature pertaining to its use for this indication. For moxibustion, moxa can be rolled into stick form, placed directly on the skin, or placed on an acupuncture needle and ignited to warm acupuncture points. Studies have demonstrated that moxibustion may promote cephalic version of breech presentation and may facilitate external cephalic version. However, there is currently a paucity of research on the effects of moxibustion on cephalic version of breech presentation, and thus there is a need for further studies. Areas needing more investigation include efficacy, safety, optimal technique, and best protocol for cephalic version of breech presentation. © 2018 by the American College of Nurse-Midwives.

  13. London SPAN version 4 parameter file format

    International Nuclear Information System (INIS)

    2004-06-01

    Powernext SA is a Multilateral Trading Facility in charge of managing the French power exchange through an optional and anonymous organised trading system. Powernext SA collaborates with the clearing organization LCH.Clearnet SA to secure and facilitate the transactions. The French Standard Portfolio Analysis of Risk (SPAN) is a system used by LCH.Clearnet to calculate the initial margins from and for its clearing members. SPAN is a computerized system which calculates the impact of several possible variations of rates and volatility on by-product portfolios. The initial margin call is equal to the maximum probable loss calculated by the system. This document contains details of the format of the London SPAN version 4 parameter file. This file contains all the parameters and risk arrays required to calculate SPAN margins. London SPAN Version 4 is an upgrade from Version 3, which is also known as LME SPAN. This document contains the full revised file specification, highlighting the changes from Version 3 to Version 4

  14. Toward a microrealistic version of quantum mechanics. II

    International Nuclear Information System (INIS)

    Maxwell, N.

    1976-01-01

    Possible objections to the propensity microrealistic version of quantum mechanics proposed previously are answered. This version of quantum mechanics is compared with the statistical, particle, microrealistic viewpoint, and a crucial experiment is proposed designed to distinguish between these two microrealistic versions of quantum mechanics

  15. COSY INFINITY Version 9

    International Nuclear Information System (INIS)

    Makino, Kyoko; Berz, Martin

    2006-01-01

    In this paper, we review the features in the newly released version of COSY INFINITY, which currently has a base of more than 1000 registered users, focusing on the topics which are new and some topics which became available after the first release of the previous versions 8 and 8.1. The recent main enhancements of the code are devoted to reliability and efficiency of the computation, to verified integration, and to rigorous global optimization. There are various data types available in COSY INFINITY to support these goals, and the paper also reviews the feature and usage of those data types

  16. Evaluation of Psychometric Properties of the Malay Version ...

    African Journals Online (AJOL)

    Evaluation of Psychometric Properties of the Malay Version Perceived Stress Scale in Two Occupational Settings In Malaysia. ... Statistical analysis was carried out using statistical package for the social sciences version 16 (SPSS, Chicago, IL, USA) software. Results: Analysis yielded two factor structure of the Malay version ...

  17. User's manual, version 1.00 for Monteburns, version 3.01

    International Nuclear Information System (INIS)

    Poston, D.I.; Trellue, H.R.

    1998-06-01

    Monteburns is a fully automated tool that links the Monte Carlo transport code MCNP with the radioactive decay and burnup code ORIGEN2. Monteburns produces a large number of criticality and burnup results based on various material feed/removal specifications, power(s), and time intervals. The program processes input from the user that specifies the system geometry, initial material compositions, feed/removal specifications, and other code-specific parameters. Various results from MCNP, ORIGEN2, and other calculations are then output successively as the code runs. The principle function of monteburns is to transfer one-group cross section and flux values from MCNP to ORIGEN2, and then transfer the resulting material compositions (after irradiation and/or decay) from ORIGEN2 back to MCNP in a repeated, cyclic fashion. The basic requirement of the code is that the user have a working MCNP input file and other input parameters; all interaction with ORIGEN2 and other calculations are performed by monteburns. This report serves as a user's manual for monteburns. It describes how the code functions, what input the user must provide, the calculations performed by the code, and it presents the format required for input files, as well as samples of these files. Monteburns is still in a developmental stage; thus, additions and/or changes may be made over time, and the user's manual will change as well. This is the first version of the user's manual (valid for monteburns version 3.01); users should contact the authors to inquire if a more recent version is available

  18. Major Upgrades to the AIRS Version-6 Ozone Profile Methodology

    Science.gov (United States)

    Susskind, Joel; Blaisdell, John; Iredell, Lena

    2015-01-01

    This research is a continuation of part of what was shown at the last AIRS Science Team Meeting in the talk Improved Water Vapor and Ozone Profiles in SRT AIRS Version-6.X and the AIRS February 11, 2015 NetMeeting Further improvements in water vapor and ozone profiles compared to Version-6.AIRS Version-6 was finalized in late 2012 and is now operational. Version-6 contained many significant improvements in retrieval methodology compared to Version-5. However, Version-6 retrieval methodology used for the water vapor profile q(p) and ozone profile O3(p) retrievals is basically unchanged from Version-5, or even from Version-4. Subsequent research has made significant improvements in both water vapor and O3 profiles compared to Version-6. This talk will concentrate on O3 profile retrievals. Improvements in water vapor profile retrievals are given in a separate presentation.

  19. Fifty years of science, memories, and events

    CERN Multimedia

    2004-01-01

    In 2004 CERN celebrates its 50th anniversary. More precisely, on Wednesday 29 September 2004, the signature of the convention that established CERN will be 50 years old. During this special year, CERN's public web site will host a celebratory Fiftieth Anniversary web site.

  20. [External cephalic version of breech presentation at term].

    Science.gov (United States)

    Albrechtsen, Susanne; Berge, Lillian N; Børdahl, Per E; Egeland, Thore; Henriksen, Tore; Håheim, Lise Lund; Øian, Pål

    2005-03-03

    External cephalic version could be an alternative to either vaginal delivery or caesarean section in breech presentation at term. A systematic literature review about external cephalic version in breech presentation. The numbers of breech presentation delivered by caesarean section could probably be reduced in Norway by offering version, but this would not affect perinatal mortality.

  1. Trace contaminant control simulation computer program, version 8.1

    Science.gov (United States)

    Perry, J. L.

    1994-01-01

    The Trace Contaminant Control Simulation computer program is a tool for assessing the performance of various process technologies for removing trace chemical contamination from a spacecraft cabin atmosphere. Included in the simulation are chemical and physical adsorption by activated charcoal, chemical adsorption by lithium hydroxide, absorption by humidity condensate, and low- and high-temperature catalytic oxidation. Means are provided for simulating regenerable as well as nonregenerable systems. The program provides an overall mass balance of chemical contaminants in a spacecraft cabin given specified generation rates. Removal rates are based on device flow rates specified by the user and calculated removal efficiencies based on cabin concentration and removal technology experimental data. Versions 1.0 through 8.0 are documented in NASA TM-108409. TM-108409 also contains a source file listing for version 8.0. Changes to version 8.0 are documented in this technical memorandum and a source file listing for the modified version, version 8.1, is provided. Detailed descriptions for the computer program subprograms are extracted from TM-108409 and modified as necessary to reflect version 8.1. Version 8.1 supersedes version 8.0. Information on a separate user's guide is available from the author.

  2. The Gaia Framework: Version Support In Web Based Open Hypermedia

    DEFF Research Database (Denmark)

    Grønbæk, Kaj; Kejser, Thomas

    2004-01-01

    The GAIA framework prototype, described herein, explores the possibilities and problems that arise when combining versioning and open hypermedia paradigms. It will be argued that it - by adding versioning as a separate service in the hypermedia architecture – is possible to build consistent...... versioning field and GAIA is compared with previous attempts at defining hypermedia versioning frameworks. GAIA is capable of multi-level versioning and versioning of structures and supports freezing mechanisms for both documents and hyperstructure. The experiences from GAIA provide an input to new reference...

  3. The Gaia Framework: Version Support In Web Based Open Hypermedia

    DEFF Research Database (Denmark)

    Kejser, Thomas; Grønbæk, Kaj

    2003-01-01

    The GAIA framework prototype, described herein, explores the possibilities and problems that arise when combining versioning and open hypermedia paradigms. It will be argued that it - by adding versioning as a separate service in the hypermedia architecture - is possible to build consistent...... versioning field and GAIA is compared with previous attempts at defining hypermedia versioning frameworks. GAIA is capable of multi-level versioning and versioning of structures and supports freezing mechanisms for both documents and hyperstructure. The experiences from GAIA provide an input to new reference...

  4. Versions of the Waste Reduction Model (WARM)

    Science.gov (United States)

    This page provides a brief chronology of changes made to EPA’s Waste Reduction Model (WARM), organized by WARM version number. The page includes brief summaries of changes and updates since the previous version.

  5. PROSA version 4.0 manual

    International Nuclear Information System (INIS)

    Bicking, U.; Golly, W.; Peter, N.; Seifert, R.

    1991-05-01

    This report includes a comprehensive manual of the computer program PROSA which illustrate the handling and functioning of PROSA. The manual PROSA 4.0 (FORTRAN 77) describes the PC Version of PROSA including its program moduls. The PROSA program package is a statistical tool to decide on the basis of statistical assumptions whether in a given sequence of material balance periods a loss of material might have occurred. The evaluation of the material balance data is based on statistical test procedures. In the present PROSA Version 4.0 the three tests CUMUF test, PAGE's test and GEMUF test are applied to a sequence of material balances. PROSA Version 4.0 supports a real sequential evaluation. That means, PROSA is not only able to evaluate a series of MUF values sequentially after the campaign has finished, but also real sequentially during the campaign. PROSA Version 4.0 is a menu-guided computer program. Data input can be performed either by diskette or by key-enter. Result output is primarily an information whether or not an alarm is indicated. This information can be displayed either numerically or graphically. Therefore, a comfortable graphical output utility is attached to PROSA 4.0. The program moduls are compiled and linked with the Ryan Mc-Farland Compiler. The PROSA graphical utility uses the PLOT88 Library of Plotworks, Inc. (orig./HP) [de

  6. Danish version of 'The COPD self-efficacy scale'

    DEFF Research Database (Denmark)

    Emme, Christina; Mortensen, Erik L; Rydahl-Hansen, Susan

    2012-01-01

    Scand J Caring Sci; 2012; 26; 615-623 Danish version of 'The COPD self-efficacy scale': translation and psychometric properties The aim of the study was to translate 'The COPD self-efficacy scale' (CSES) into Danish and to evaluate the psychometric properties of the Danish version (CSES-DK). CSES...... enables assessment of self-efficacy in individuals with chronic obstructive pulmonary disease (COPD). The scale consists of 34 items, describing situations which may cause dyspnoea in patients with COPD. The CSES was translated into Danish using a standard forward-backward translation procedure...... analysis was conducted to compare the internal structure of the Danish version and the American source version. The study included 151 patients with COPD, recruited from three outpatient clinics. Estimates of reliability were in accordance with the original version of CSES (Cronbach's a = 0.97, test...

  7. Ecodesign Directive version 2.0

    DEFF Research Database (Denmark)

    This present report reports on the main findings of the project Ecodesign Directive version 2.0 - from Energy Efficiency to Resource Efficiency. The project is financed by the Danish Environmental Protection Agency and ran from December 2012 to June 2014.......This present report reports on the main findings of the project Ecodesign Directive version 2.0 - from Energy Efficiency to Resource Efficiency. The project is financed by the Danish Environmental Protection Agency and ran from December 2012 to June 2014....

  8. [Fetal version as ambulatory intervention].

    Science.gov (United States)

    Nohe, G; Hartmann, W; Klapproth, C E

    1996-06-01

    The external cephalic version (ECV) of the fetus at term reduces the maternal and fetal risks of intrapartum breech presentation and Caesarean delivery. Since 1986 over 800 external cephalic versions were performed in the outpatient Department of Obstetrics and Gynaecology of the Städtische Frauenklinik Stuttgart. 60.5% were successful. NO severe complications occurred. Sufficient amniotic fluid as well as the mobility of the fetal breech is a major criterion for the success of the ECV. Management requires a safe technique for mother and fetus. This includes ultrasonography, elektronic fetal monitoring and the ability to perform immediate caesarean delivery as well as the performance of ECV without analgesicas and sedatives. More than 70% of the ECV were successful without tocolysis. In unsuccessful cases the additional use of tocolysis improves the success rate only slightly. Therefore routine use of tocolysis does not appear necessary. External cephalic version can be recommended as an outpatient treatment without tocolysis.

  9. Red Mandela: Contests of auto-biography and Auto/biography in South Africa

    Directory of Open Access Journals (Sweden)

    Ciraj Rassool

    Full Text Available This article examines the case of the red Mercedes-Benz built in 1990 by workers at the Mercedes-Benz plant in East London and presented to Nelson Mandela as a gift shortly after his release from prison. During the 1990s a biographic order marked by a discourse of heroic leaders was growing in South Africa, where biographic narration and self-narration played a noticeable and, at times, substantial part in political transformation and reconstruction. Nelson Mandela's 'long walk to freedom' became the key trope for South Africa's history, narrated as the triumph of reconciliation. The presentation of the car to Nelson Mandela in 1990 occurred at a time of transition in the life of his auto/biography, from the biography of desire for the absent revolutionary leader to the biography of a statesman and president. This partly explains the ambiguous, double-edged history of the gift, as a labour of love on the part of NUMSA workers and as donation by Mercedes-Benz South Africa (the corporate version of these events emphasised the 'friendship' that was 'sparked' between Nelson Mandela and Mercedes-Benz South Africa. Inspired by the East London autoworkers' commitment to produce the car for Mandela, as well as by the resilience some of them showed during their nine-week strike and sleep-in in the plant soon afterwards, Simon Gush's installation Red has intervened in how those events should be remembered. By choosing to exhibit the disassembled body panels of a replica car alongside reconstructed displays of sleep-in strike beds made of scaffolding, foam, upholstery and car headrests, with imagined uniforms of striking workers, Gush has chosen to appropriate the history of the events of 1990 from the celebratory frames of the Mandela biographic order. The installation turns into an inquiry into the labour process and the events of the strike that was critical of the reconciliatory and celebratory understanding of the gift as a product of a partnership

  10. Detect-PC Software Version 3.0

    International Nuclear Information System (INIS)

    Arista Romeu, E. J.

    2011-01-01

    The 'Thyroid uptake system Detect-PC' developed and manufactured at CEADEN is object of follow-up by its manufacturer in order to fulfill the established national requirements to medical equipment. Taking into account observations from the users of the system, several modifications were implemented that resulted in a new software version, the 3.0.0. These modifications were mainly introduced to easy carrying out the energetic calibration of the system. In this new version all the working modes of the system were thoroughly tested and a Medic Physics was trained in the use of the application software. Acceptance tests were carried out in a thyroid uptake system installed in the Hermanos Ameijeiras Hospital, where this version of the software remained installed and in operation. (Author)

  11. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION)

    Science.gov (United States)

    Riley, G.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  12. TAE+ 5.2 - TRANSPORTABLE APPLICATIONS ENVIRONMENT PLUS, VERSION 5.2 (DEC RISC ULTRIX VERSION)

    Science.gov (United States)

    TAE SUPPORT OFFICE

    1994-01-01

    programs to display and control the user interfaces. Since the WPTs access the workbench-generated resource files during each execution, details such as color, font, location, and object type remain independent from the application code, allowing changes to the user interface without recompiling and relinking. In addition to WPTs, TAE Plus can control interaction of objects from the interpreted TAE Command Language. TCL provides a means for the more experienced developer to quickly prototype an application's use of TAE Plus interaction objects and add programming logic without the overhead of compiling or linking. TAE Plus requires MIT's X Window System and the Open Software Foundation's Motif. The HP 9000 Series 700/800 version of TAE 5.2 requires Version 11 Release 5 of the X Window System. All other machine versions of TAE 5.2 require Version 11, Release 4 of the X Window System. The Workbench and WPTs are written in C++ and the remaining code is written in C. TAE Plus is available by license for an unlimited time period. The licensed program product includes the TAE Plus source code and one set of supporting documentation. Additional documentation may be purchased separately at the price indicated below. The amount of disk space required to load the TAE Plus tar format tape is between 35Mb and 67Mb depending on the machine version. The recommended minimum memory is 12Mb. Each TAE Plus platform delivery tape includes pre-built libraries and executable binary code for that particular machine, as well as source code, so users do not have to do an installation. Users wishing to recompile the source will need both a C compiler and either GNU's C++ Version 1.39 or later, or a C++ compiler based on AT&T 2.0 cfront. TAE Plus was developed in 1989 and version 5.2 was released in 1993. TAE Plus 5.2 is available on media suitable for five different machine platforms: (1) IBM RS/6000 series workstations running AIX (.25 inch tape cartridge in UNIX tar format), (2) DEC RISC

  13. Neuraxial blockade for external cephalic version: Cost analysis.

    Science.gov (United States)

    Yamasato, Kelly; Kaneshiro, Bliss; Salcedo, Jennifer

    2015-07-01

    Neuraxial blockade (epidural or spinal anesthesia/analgesia) with external cephalic version increases the external cephalic version success rate. Hospitals and insurers may affect access to neuraxial blockade for external cephalic version, but the costs to these institutions remain largely unstudied. The objective of this study was to perform a cost analysis of neuraxial blockade use during external cephalic version from hospital and insurance payer perspectives. Secondarily, we estimated the effect of neuraxial blockade on cesarean delivery rates. A decision-analysis model was developed using costs and probabilities occurring prenatally through the delivery hospital admission. Model inputs were derived from the literature, national databases, and local supply costs. Univariate and bivariate sensitivity analyses and Monte Carlo simulations were performed to assess model robustness. Neuraxial blockade was cost saving to both hospitals ($30 per delivery) and insurers ($539 per delivery) using baseline estimates. From both perspectives, however, the model was sensitive to multiple variables. Monte Carlo simulation indicated neuraxial blockade to be more costly in approximately 50% of scenarios. The model demonstrated that routine use of neuraxial blockade during external cephalic version, compared to no neuraxial blockade, prevented 17 cesarean deliveries for every 100 external cephalic versions attempted. Neuraxial blockade is associated with minimal hospital and insurer cost changes in the setting of external cephalic version, while reducing the cesarean delivery rate. © 2015 The Authors. Journal of Obstetrics and Gynaecology Research © 2015 Japan Society of Obstetrics and Gynecology.

  14. MCNP Version 6.2 Release Notes

    Energy Technology Data Exchange (ETDEWEB)

    Werner, Christopher John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bull, Jeffrey S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Solomon, C. J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Forrest B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McKinney, Gregg Walter [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rising, Michael Evan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dixon, David A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martz, Roger Lee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hughes, Henry G. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cox, Lawrence James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Zukaitis, Anthony J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Armstrong, J. C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Forster, Robert Arthur [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Casswell, Laura [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-02-05

    Monte Carlo N-Particle or MCNP® is a general-purpose Monte Carlo radiation-transport code designed to track many particle types over broad ranges of energies. This MCNP Version 6.2 follows the MCNP6.1.1 beta version and has been released in order to provide the radiation transport community with the latest feature developments and bug fixes for MCNP. Since the last release of MCNP major work has been conducted to improve the code base, add features, and provide tools to facilitate ease of use of MCNP version 6.2 as well as the analysis of results. These release notes serve as a general guide for the new/improved physics, source, data, tallies, unstructured mesh, code enhancements and tools. For more detailed information on each of the topics, please refer to the appropriate references or the user manual which can be found at http://mcnp.lanl.gov. This release of MCNP version 6.2 contains 39 new features in addition to 172 bug fixes and code enhancements. There are still some 33 known issues the user should familiarize themselves with (see Appendix).

  15. Several versions of forward gas ionization calorimeter

    International Nuclear Information System (INIS)

    Babintsev, V.V.; Kholodenko, A.G.; Rodnov, Yu.V.

    1994-01-01

    The properties of several versions of a gas ionization calorimeter are analyzed by means of the simulation with the GEANT code. The jet energy and coordinate resolutions are evaluated. Some versions of the forward calorimeter meet the ATLAS requirements. 13 refs., 15 figs., 7 tabs

  16. Major Upgrades to the AIRS Version-6 Water Vapor Profile Methodology

    Science.gov (United States)

    Susskind, Joel; Blaisdell, John; Iredell, Lena

    2015-01-01

    This research is a continuation of part of what was shown at the last AIRS Science Team Meeting and the AIRS 2015 NetMeeting. AIRS Version 6 was finalized in late 2012 and is now operational. Version 6 contained many significant improvements in retrieval methodology compared to Version 5. Version 6 retrieval methodology used for the water vapor profile q(p) and ozone profile O3(p) retrievals is basically unchanged from Version 5, or even from Version 4. Subsequent research has made significant improvements in both water vapor and O3 profiles compared to Version 6.

  17. Reproducibility of the Portuguese version of the PEDro Scale

    Directory of Open Access Journals (Sweden)

    Silvia Regina Shiwa

    2011-10-01

    Full Text Available The objective of this study was to test the inter-rater reproducibility of the Portuguese version of the PEDro Scale. Seven physiotherapists rated the methodological quality of 50 reports of randomized controlled trials written in Portuguese indexed on the PEDro database. Each report was also rated using the English version of the PEDro Scale. Reproducibility was evaluated by comparing two separate ratings of reports written in Portuguese and comparing the Portuguese PEDro score with the English version of the scale. Kappa coefficients ranged from 0.53 to 1.00 for individual item and an intraclass correlation coefficient (ICC of 0.82 for the total PEDro score was observed. The standard error of the measurement of the scale was 0.58. The Portuguese version of the scale was comparable with the English version, with an ICC of 0.78. The inter-rater reproducibility of the Brazilian Portuguese PEDro Scale is adequate and similar to the original English version.

  18. Nuclear criticality safety handbook. Version 2

    International Nuclear Information System (INIS)

    1999-03-01

    The Nuclear Criticality Safety Handbook, Version 2 essentially includes the description of the Supplement Report to the Nuclear Criticality Safety Handbook, released in 1995, into the first version of Nuclear Criticality Safety Handbook, published in 1988. The following two points are new: (1) exemplifying safety margins related to modelled dissolution and extraction processes, (2) describing evaluation methods and alarm system for criticality accidents. Revision is made based on previous studies for the chapter that treats modelling the fuel system: e.g., the fuel grain size that the system can be regarded as homogeneous, non-uniformity effect of fuel solution, and burnup credit. This revision solves the inconsistencies found in the first version between the evaluation of errors found in JACS code system and criticality condition data that were calculated based on the evaluation. (author)

  19. A Multi-threaded Version of Field II

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2014-01-01

    A multi-threaded version of Field II has been developed, which automatically can use the multi-core capabil- ities of modern CPUs. The memory allocation routines were rewritten to minimize the number of dynamic allocations and to make pre-allocations possible for each thread. This ensures...... that the simulation job can be automatically partitioned and the interdependence between threads minimized. The new code has been compared to Field II version 3.22, October 27, 2013 (latest free-ware version). A 64 element 5 MHz focused array transducer was simulated. One million point scatterers randomly distributed...... in a plane of 20 x 50 mm (width x depth) with random Gaussian amplitudes were simulated using the command calc scat . Dual Intel Xeon CPU E5-2630 2.60 GHz CPUs were used under Ubuntu Linux 10.02 and Matlab version 2013b. Each CPU holds 6 cores with hyper-threading, corresponding to a total of 24 hyper...

  20. The Role of Law Enforcement in Prevention. Prevention Update

    Science.gov (United States)

    Higher Education Center for Alcohol, Drug Abuse, and Violence Prevention, 2011

    2011-01-01

    As campuses and communities across the country grapple with problems related to unruly house parties, neighborhood disruptions, and alcohol-fueled "celebratory" incidents, they are developing partnerships with law enforcement agencies to implement strategies to reduce such problems and protect the health and safety of students and residents alike.…

  1. SHUFFLE. Windows 95/98/2000 version

    International Nuclear Information System (INIS)

    Slavic, S.; Zefran, B.

    2000-01-01

    Program package SHUFFLE was developed to help the user during fuel loading and unloading operations at a nuclear power plant. The first version, developed in 1992, has been written in the CLIPPER program language and run under the DOS operating system. Since the DOS environment exhibits several drawbacks regarding code portability and flexibility, the recent SHUFFLE version has been transformed to run under the MS Windows operating system. (author)

  2. External cephalic version facilitation for breech presentation at term.

    Science.gov (United States)

    Hofmeyr, G J

    2001-01-01

    Tocolytic drugs to relax the uterus as well as other methods have been also used in an attempt to facilitate external cephalic version at term. The objective of this review is to assess the effects of routine tocolysis, fetal acoustic stimulation, epidural or spinal analgesia and transabdominal amnioinfusion for external cephalic version at term on successful version and measures of pregnancy outcome. The Cochrane Pregnancy and Childbirth Group Trials Register and the Cochrane Controlled Trials Register were searched. Date of last search: April 2001. Randomised and quasi-randomised trials comparing routine versus selective tocolysis; fetal acoustic stimulation in midline fetal spine positions versus dummy or no stimulation; epidural or spinal analgesia versus no regional analgesia; or transabdominal amnioinfusion versus no amnioinfusion for external cephalic version at term. Eligibility and trial quality were assessed by the reviewer. In seven trials, routine tocolysis was associated with fewer failures of external cephalic version (relative risk 0.74, 95% confidence interval 0.64 to 0.87). There were no significant differences between non-cephalic presentations at birth. Caesarean sections were reduced (relative risk 0.85, confidence interval 0.72-0.99). Fetal acoustic stimulation in midline fetal spine positions was associated with fewer failures of external cephalic version at term (relative risk 0.17, 95% confidence interval 0.05 to 0.60). With epidural or spinal analgesia, external cephalic version failure, non-cephalic births and caesarean sections were reduced in one trial but not the other. The overall differences were not statistically significant. No randomised trials of transabdominal amnioinfusion for external cephalic version at term were located. Routine tocolysis appears to reduce the failure rate of external cephalic version at term. Although promising, there is not enough evidence to evaluate the use of fetal acoustic stimulation in midline fetal

  3. ENDF-6 formats manual. Version of Oct. 1991

    International Nuclear Information System (INIS)

    Rose, P.F.; Dunford, C.L.

    1992-01-01

    ENDF-6 is the international computer file format for evaluated nuclear data. In contrast to the earlier versions (ENDF-4 and ENDF-5) the new version ENDF-6 has been designed not only for neutron reaction data but also for photo-nuclear and charged-particle nuclear reaction data. This document gives a detailed description of the formats and procedures adopted for ENDF-6. The present version includes update pages dated Oct. 1991. (author). Refs, figs, and tabs

  4. Anesthetic management of external cephalic version.

    Science.gov (United States)

    Chalifoux, Laurie A; Sullivan, John T

    2013-09-01

    Breech presentation is common at term and its reduction through external cephalic version represents a noninvasive opportunity to avoid cesarean delivery and the associated maternal morbidity. In addition to uterine relaxants, neuraxial anesthesia is associated with increased success of version procedures when surgical anesthetic dosing is used. The intervention is likely cost effective given the effect size and the avoided high costs of cesarean delivery. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Implementing version support for complex objects

    OpenAIRE

    Blanken, Henk

    1991-01-01

    New applications in the area of office information systems, computer aided design and manufacturing make new demands upon database management systems. Among others highly structured objects and their history have to be represented and manipulated. The paper discusses some general problems concerning the access and storage of complex objects with their versions and the solutions developed within the AIM/II project. Queries related to versions are distinguished in ASOF queries (asking informati...

  6. External cephalic version before elective caesarean section for breech presentation

    International Nuclear Information System (INIS)

    Zafar, F.; Sanusi, A.

    2008-01-01

    The Royal College of Obstetrics and Gynaecology guidelines state that all uncomplicated breech Presentation should be offered external cephalic version and all such women should be briefed about the risks and benefits of external cephalic version and all such women should be briefed about the risks and benefits of external cephalic version before undertaking the procedure. To ascertain the acceptability of external cephalic version before elective caesarean section for breech Presentation by pregnant ladies and see whether they were adequately informed about the risks and benefits. The clinical audit was registered with the audit department at Watford general hospital and written Consent for the access of medical records was obtained. A retrospective view of 86 accessible medical records out of Total 110 elective breech caesarean sections was done over a period of one year. This retrospective study was conducted at the gynaecology and obstetrics department at Watford general hospital, Watford United Kingdom. Written consent for the access of medical records was obtained. All women who under went elective caesarean section due to breech presentation were included in the study. Out of a total of 110 elective breech caesarean sections performed, the data on 86 cases was selected for the final analysis. The information gathered included patient's profile, whether patient was informed of risks and benefits of external cephalic version, recognition of obstetric risk factors, external cephalic version performed and its success. Out of total 86 caesarean sections 46 were suitable for external cephalic version of whom 37 cases were offered external cephalic version. Among 37 patients who were offered external cephalic version only 15 patients accepted (22 declined) the procedure. Moreover, it was found that the documentation of risk/benefit explanation of the procedure was inadequate. External cephalic version was not successful in any of the patient. Causes for

  7. A Statistical Review of CALIOP Version 3 and Version 4 Cloud Aerosol Discrimination

    Science.gov (United States)

    Zeng, S.

    2016-12-01

    The Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) on board the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) mission has now delivered a 10-year record of high-resolution profiles of backscatter at 532 nm and 1064 nm and linear depolarization at 532 nm. These long-term active sensor measurements at global scale have led to significant advances in our understanding of the vertical distribution of clouds and aerosols in the atmosphere. In the fall of 2016, the CALIPSO science team is scheduled to release a new version of their cloud and aerosol data products. The new cloud and aerosol discrimination products are derived using updated probability density functions that account for numerous improvements to the CALIOP calibration and the use of the GMAO MERRA-2 meteorological data. Moreover, the CAD algorithm is now applied to all layers detected, thus greatly improving the identification of such features as overshooting convective clouds, stratospheric aerosol layers, and high intensity dust storms. Post-processing modules are added to the standard CAD algorithm to ensure proper identification of (for example) the tenuous edges of cirrus clouds and water clouds lying beneath optically dense smoke layers. This work presents statistical comparisons between the CALIOP version 3 and version 4 data sets. Areas of improvement are highlighted, sources of continuing uncertainty are discussed and a list of best practices for data users is provided.

  8. Validity and reliability of the Brazilian version of Yale-Brown obsessive compulsive scale-shopping version (YBOCS-SV).

    Science.gov (United States)

    Leite, Priscilla Lourenço; Filomensky, Tatiana Zambrano; Black, Donald W; Silva, Adriana Cardoso

    2014-08-01

    The Yale-Brown Obsessive Compulsive Scale-Shopping Version (YBOCS-SV) is considered the gold standard in the assessment of shopping severity. It is designed to assess cognitions and behaviors relating to compulsive buying behavior. The present study aims to assess the validity of the Brazilian version of this scale. For the study, composed the sample 610 participants: 588 subjects of a general population and 22 compulsive buyers. Factorial analysis was performed to assess the relations and the correlation between the YBOCS-SV, the Compulsive Buying Scale (CBS), and Richmond Compulsive Buying Scale (RCBS), was assessed using Pearson coefficient, for study of convergent and divergent validity. Cronbach's alpha coefficients were used to assess internal consistency. The results show good to excellent psychometric parameters for the YBOCS-SV in its Brazilian version. With regard to correlations, the YBOCS-SV is inversely and proportionally correlated with CBS and the RCBS, indicating that the YBOCS-SV is an excellent instrument for screening compulsive buying. The YBOCS-SV presented high alpha coefficient of Cronbach's alpha (0.92), demonstrating good reliability. The Brazilian version of the YBOCS-SV is indicated to diagnose compulsive buying disorder, and likely use for the purposes intended in the Brazilian population. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Development and tests of short versions of the Youth Psychopathic traits Inventory and the Youth Psychopathic traits Inventory-Child Version

    NARCIS (Netherlands)

    van Baardewijk, Y.; Andershed, H.; Stegge, G.T.M.; Nilsson, K.W.; Scholte, E.; Vermeiren, R.R.J.M.

    2010-01-01

    The adolescent Youth Psychopathic Traits Inventory (YPI) and its child version (YPI-CV) are sound but lengthy instruments for measuring psychopathic traits in youths. The current study develops psychometrically strong short versions of these instruments. Samples used for item reduction were

  10. Integrated Farm System Model Version 4.3 and Dairy Gas Emissions Model Version 3.3 Software development and distribution

    Science.gov (United States)

    Modeling routines of the Integrated Farm System Model (IFSM version 4.2) and Dairy Gas Emission Model (DairyGEM version 3.2), two whole-farm simulation models developed and maintained by USDA-ARS, were revised with new components for: (1) simulation of ammonia (NH3) and greenhouse gas emissions gene...

  11. The Oswestry Disability Index (version 2.1a): validation of a Dutch language version.

    Science.gov (United States)

    van Hooff, Miranda L; Spruit, Maarten; Fairbank, Jeremy C T; van Limbeek, Jacques; Jacobs, Wilco C H

    2015-01-15

    A cross-sectional study on baseline data. To translate the Oswestry Disability Index (ODI) version 2.1a into the Dutch language and to validate its use in a cohort of patients with chronic low back pain in secondary spine care. Patient-reported outcome measures (PROMs) are commonly accepted to evaluate the outcome of spine interventions. Functional status is an important outcome in spine research. The ODI is a recommended condition-specific patient-reported outcome measure used to evaluate functional status in patients with back pain. As yet, no formal translated Dutch version exists. The ODI was translated according to established guidelines. The final version was built into the electronic web-based system in addition with the Roland Morris Disability Questionnaire, the numeric rating scale for pain severity, 36-Item Short Form Health Survey Questionnaire for quality of life, and the hospital anxiety and depression scale. Baseline data were used of 244 patients with chronic low back pain who participated in a combined physical and psychological program. Floor and ceiling effects, internal consistency, and the construct validity were evaluated using quality criteria. The mean ODI (standard deviation) was 39.6 (12.3); minimum 6, maximum 70. Most of the participants (88%) were moderately to severely disabled. Factor analysis determined a 1-factor structure (36% explained variance) and the homogeneity of ODI items is shown (Cronbach α = 0.79). The construct validity is supported as all (6:6) the a priori hypotheses were confirmed. Moreover, the ODI and Roland Morris Disability Questionnaire, showed a strong significant correlation (r = 0.68, P disability among Dutch patients with chronic low back pain. This translated condition-specific patient-reported outcome measure version is recommended for use in future back pain research and to evaluate outcome of back care in the Netherlands.

  12. Version control of pathway models using XML patches.

    Science.gov (United States)

    Saffrey, Peter; Orton, Richard

    2009-03-17

    Computational modelling has become an important tool in understanding biological systems such as signalling pathways. With an increase in size complexity of models comes a need for techniques to manage model versions and their relationship to one another. Model version control for pathway models shares some of the features of software version control but has a number of differences that warrant a specific solution. We present a model version control method, along with a prototype implementation, based on XML patches. We show its application to the EGF/RAS/RAF pathway. Our method allows quick and convenient storage of a wide range of model variations and enables a thorough explanation of these variations. Trying to produce these results without such methods results in slow and cumbersome development that is prone to frustration and human error.

  13. Validity of the Spanish version of the Emotional Labour Scale.

    Science.gov (United States)

    Picardo, Juan M; López-Fernández, Consuelo; Hervás, María José Abellán

    2014-06-01

    In this article we address concerns raised by Brumit and Glenn (2013) regarding the validity of the Spanish version of the Emotional Labour Scale (ELS). We respond to requests in relation to the translated version of the scale and the eigenvalue series. We also give an explanation of the differences in results between the original version and the Spanish version of the scale. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Analysis of Handling Processes of Record Versions in NoSQL Databases

    Directory of Open Access Journals (Sweden)

    Yu. A. Grigorev

    2015-01-01

    Full Text Available This article investigates the handling processes versions of a record in NoSQL databases. The goal of this work is to develop a model, which enables users both to handle record versions and work with a record simultaneously. This model allows us to estimate both a time distribution for users to handle record versions and a distribution of the count of record versions. With eventual consistency (W=R=1 there is a possibility for several users to update any record simultaneously. In this case, several versions of records with the same key will be stored in database. When reading, the user obtains all versions, handles them, and saves a new version, while older versions are deleted. According to the model, the user’s time for handling the record versions consists of two parts: random handling time of each version and random deliberation time for handling a result. Record saving time and records deleting time are much less than handling time, so, they are ignored in the model. The paper offers two model variants. According to the first variant, client's handling time of one record version is calculated as the sum of random handling times of one version based on the count of record versions. This variant ignores explicitly the fact that handling time of record versions may depend on the update count, performed by the other users between the sequential updates of the record by the current client. So there is the second variant, which takes this feature into consideration. The developed models were implemented in the GPSS environment. The model experiments with different counts of clients and different ratio between one record handling time and results deliberation time were conducted. The analysis showed that despite the resemblance of model variants, a difference in change nature between average values of record versions count and handling time is significant. In the second variant dependences of the average count of record versions in database and

  15. Intergenerational Panels at Centennial Events: Stimulating Discussion about Continuity and Change in the 4-H Program

    Science.gov (United States)

    Kaplan, Matthew S.; Weikert, Ben; Scholl, Jan; Rushton, Mya

    2013-01-01

    This article introduces an intergenerational strategy for organizations planning centennial celebratory events. The methods and findings from the 4-H through the Generations session conducted at the joint 4-H Leadership Conference and 4-H Leaders Forum to celebrate the Pennsylvania 4-H Centennial are reported. Youth and adult participants shared…

  16. Commercial Social Media and the Erosion of the Commons: Implications for Academic Libraries

    Science.gov (United States)

    Lilburn, Jeff

    2012-01-01

    Recent scholarship challenges the celebratory discourse surrounding Web 2.0. This paper engages with this scholarship to examine critically the implications of academic libraries' presence within commercially owned social media spaces. It considers the apparent contradiction between work to promote the principles of open access and the idea of the…

  17. Producing Neoliberal Citizens: Critical Reflections on Human Rights Education in Pakistan

    Science.gov (United States)

    Khoja-Moolji, Shenila

    2014-01-01

    This paper challenges the celebratory uptake of human rights education (HRE) in postcolonial contexts by making visible the ideological and political entanglements of the discourse with neoliberal assumptions of citizenship. I draw evidence from, and critically reflect on, a specific HRE programme--a series of summer camps for girls entitled,…

  18. Neuraxial blockade for external cephalic version: a systematic review.

    Science.gov (United States)

    Sultan, P; Carvalho, B

    2011-10-01

    The desire to decrease the number of cesarean deliveries has renewed interest in external cephalic version. The rationale for using neuraxial blockade to facilitate external cephalic version is to provide abdominal muscular relaxation and reduce patient discomfort during the procedure, so permitting successful repositioning of the fetus to a cephalic presentation. This review systematically examined the current evidence to determine the safety and efficacy of neuraxial anesthesia or analgesia when used for external cephalic version. A systematic literature review of studies that examined success rates of external cephalic version with neuraxial anesthesia was performed. Published articles written in English between 1945 and 2010 were identified using the Medline, Cochrane, EMBASE and Web of Sciences databases. Six, randomized controlled studies were identified. Neuraxial blockade significantly improved the success rate in four of these six studies. A further six non-randomized studies were identified, of which four studies with control groups found that neuraxial blockade increased the success rate of external cephalic version. Despite over 850 patients being included in the 12 studies reviewed, placental abruption was reported in only one patient with a neuraxial block, compared with two in the control groups. The incidence of non-reassuring fetal heart rate requiring cesarean delivery in the anesthesia groups was 0.44% (95% CI 0.15-1.32). Neuraxial blockade improved the likelihood of success during external cephalic version, although the dosing regimen that provides optimal conditions for successful version is unclear. Anesthetic rather than analgesic doses of local anesthetics may improve success. The findings suggest that neuraxial blockade does not compromise maternal or fetal safety during external cephalic version. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  19. Standardisation of gujrati version of middlesex hospital questionnaire.

    Science.gov (United States)

    Gada, M T

    1981-04-01

    The Middlesex Hospital Questionnaire is a short clinical diagnostic self rating scale for psychoneurotic patients constructed by Crown and Crisp (1966). Aim of the present study was to prepare Gujarati Version of the M.H.Q. and to establish the reliability and validity of the same.Gujarati version of the M.H.Q. was given to 204 normal population consisting of university students, school teachers, factory workers, house wives and middle aged men from different walks of the life to test the validity. The test was also administered to 30 neurotic patients. This Gujarati version was found to be reliable. There was highly significant difference between normal population and neurotic patients on total score and on all the six subtests, thus establishing the validity of the Gujarati version. It also related well with the clinical diagnosis in most of the cases.

  20. Cubical version of combinatorial differential forms

    DEFF Research Database (Denmark)

    Kock, Anders

    2010-01-01

    The theory of combinatorial differential forms is usually presented in simplicial terms. We present here a cubical version; it depends on the possibility of forming affine combinations of mutual neighbour points in a manifold, in the context of synthetic differential geometry.......The theory of combinatorial differential forms is usually presented in simplicial terms. We present here a cubical version; it depends on the possibility of forming affine combinations of mutual neighbour points in a manifold, in the context of synthetic differential geometry....

  1. Stratified B-trees and versioning dictionaries

    OpenAIRE

    Twigg, Andy; Byde, Andrew; Milos, Grzegorz; Moreton, Tim; Wilkes, John; Wilkie, Tom

    2011-01-01

    A classic versioned data structure in storage and computer science is the copy-on-write (CoW) B-tree -- it underlies many of today's file systems and databases, including WAFL, ZFS, Btrfs and more. Unfortunately, it doesn't inherit the B-tree's optimality properties; it has poor space utilization, cannot offer fast updates, and relies on random IO to scale. Yet, nothing better has been developed since. We describe the `stratified B-tree', which beats all known semi-external memory versioned B...

  2. Tyd as gawe – God se tyd: Die polsslag van die kerkjaar | Kloppers ...

    African Journals Online (AJOL)

    When seen as a gift – as God's time – the careful shaping of the church year strengthens the celebratory character of the worship service; contributes to the effective proclamation of the Word; underlies the church's confession; introduces new people and young people to the faith; forms community; adds to comforting people; ...

  3. Learning and Celebrating: The Glamour of Design Lecture Series

    Science.gov (United States)

    Popov, Lubomir

    2013-01-01

    The purpose of this paper is to highlight the celebratory aspect of the Design Lecture Series, a tradition in architecture schools and interior design programs, its meaning for all constituent parties, and its contributions to creating professional identity and community. The Design Lecture Series is a public event popular in design programs,…

  4. Why Learner-Centered New Faculty Orientations Matter: Organizational Culture and Faculty Retention

    Science.gov (United States)

    Scott, Whitney; Lemus, Daisy; Knotts, Greg; Oh, Janet

    2016-01-01

    A learner-centered New Faculty Orientation (NFO) can be a powerful way to immediately engage new faculty and develop their organizational identification to the institution and its values. Unfortunately, some NFOs do not model a learner-centered philosophy and miss opportunities to establish a collaborative and celebratory tone. In this paper, we…

  5. The Reliability and Validity of the Japanese Version of the Stroke Impact Scale Version 3.0.

    Science.gov (United States)

    Ochi, Mitsuhiro; Ohashi, Hiroshi; Hachisuka, Kenji; Saeki, Satoru

    It is important to evaluate body functions and structures, activity, and participation in stroke rehabilitation. The Stroke Impact Scale (SIS), a new stroke-specific self-report measure that was developed by Duncan et al, is widely used to measure multidimensional consequences about health-related quality of life. The SIS version 3.0 includes 9 domains (strength, hand function, activity of daily living and instrumental activity of daily living, mobility, communication, emotion, memory and thinking, participation, and recovery). Patients are asked to make a percentage rating of their recovery since their stroke on a visual analog scale of 0 to 100 for the stroke recovery domain. Each item in the 8 domains other than stroke recovery are scored in a range of 1 to 5 as a raw score and calculated using the manual to a final score. We developed a Japanese version of the SIS version 3.0 and assessed its reliability and validity in 32 chronic stroke survivors. The internal consistency (Cronbach's α 3.0 is valid, reliable, and clinically useful for stroke survivors.

  6. Itil version 3 at a glance information quick reference

    CERN Document Server

    Long, John

    2008-01-01

    ITILA(R) Version 3 At a Glance takes a graphical approach to consolidating the information of ITILA(R) version 3. ITILA(R) is an internationally-recognized set of best practices for providing IT service management. IT organizations worldwide are implementing ITILA(R) as a vehicle for improving IT service quality and improve return on investment for IT services. The desk referencea (TM)s unique graphical approach will take otherwise complex textual descriptions and make the information accessible in a series of consistent, simple diagrams. ITILA(R) Version 3 At a Glance will be of interest to organizations looking to train their staffs in a consistent and cost-effective way. Further, this book is ideal for anyone involved in planning consulting, implementing, or testing an ITILA(R) Version 3 implementation. Each chapter in ITILA(R) Version 3 at a Glance summarizes one of the ITILA(R) v3 books in the following consistent structure: - Brief Description of the Stage - Overview Diagram of the Stage - Key Concepts ...

  7. External Cephalic Version-Related Risks A Meta-analysis

    NARCIS (Netherlands)

    Grootscholten, Kim; Kok, Marjolein; Oei, S. Guid; Mol, Ben W. J.; van der Post, Joris A.

    2008-01-01

    OBJECTIVE: To systematically review the literature on external cephalic version-related complications and to assess if the outcome of a version attempt is related to complications. DATA SOURCES: In March 2007 we searched MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials.

  8. Intravenous nitroglycerin for external cephalic version: a randomized controlled trial.

    Science.gov (United States)

    Hilton, Jennifer; Allan, Bruce; Swaby, Cheryl; Wahba, Raouf; Wah, Raouf; Jarrell, John; Wood, Stephen; Ross, Sue; Tran, Quynh

    2009-09-01

    To estimate whether treatment with intravenous nitroglycerin for uterine relaxation increases the chance of successful external cephalic version. Two double-blind, randomized clinical trials were undertaken: one in nulliparous women and a second in multiparous women. Women presenting for external cephalic version at term were eligible to participate. The primary outcome was immediate success of external cephalic version. Other outcomes were presentation at delivery, cesarean delivery rate, and side effects and complications. Sample size calculations were based on a 100% increase in success of external cephalic version with a one-sided analysis and alpha=0.05 (80% power). In total, 126 women were recruited-82 in the nulliparous trial and 44 in the multiparous trial. Seven patients did not have external cephalic version before delivery but were included in the analysis of success of external cephalic version. One patient was lost to follow-up. The external cephalic version success rate for nulliparous patients was 24% (10 of 42) in patients who received nitroglycerin compared with 8% (3 of 40) in those who receive placebo (P=.04, one-sided Fisher exact test, odds ratio 3.85, lower bound 1.22). In multiparous patients, the external cephalic version success rate did not differ significantly between groups: 44% (10 of 23) in the nitroglycerin group compared with 43% (9 of 21) in the placebo group (P=.60). Treatment with intravenous nitroglycerin increased the rate of successful external cephalic version in nulliparous, but not in multiparous, women. Treatment with intravenous nitroglycerin appeared to be safe, but our numbers were too small to rule out rare serious adverse effects. I.

  9. ISO-PC Version 1.98: User`s guide

    Energy Technology Data Exchange (ETDEWEB)

    Rittmann, P.D.

    1995-05-02

    This document describes how to use Version 1.98 of the shielding program named ISO-PC. Version 1.98 corrects all known errors in ISOSHLD-II. In addition, a few numeric problems have been eliminated. There are three new namelist variables, 25 additional shielding materials, and 5 more energy groups. The two major differences with the original ISOSHLD-II are the removal of RIBD(radioisotope buildup and decay) source generator, and the removal of the non-uniform source distribution parameter, SSV1. This version of ISO-PC works with photon energies from 10 KeV to 10 MeV using 30 energy groups.

  10. URGENCES NOUVELLE VERSION

    CERN Multimedia

    Medical Service

    2002-01-01

    The table of emergency numbers that appeared in Bulletin 10/2002 is out of date. The updated version provided by the Medical Service appears on the following page. Please disregard the previous version. URGENT NEED OF A DOCTOR GENEVAPATIENT NOT FIT TO BE MOVED: Call your family doctor Or SOS MEDECINS (24H/24H) 748 49 50 Or ASSOC. OF GENEVA DOCTORS (7H-23H) 322 20 20 PATIENT CAN BE MOVED: HOPITAL CANTONAL 24 Micheli du Crest 372 33 11 382 33 11 CHILDREN'S HOSPITAL 6 rue Willy Donzé 382 68 18 382 45 55 MATERNITY 24 Micheli du Crest 382 68 16 382 33 11 OPHTALMOLOGY 22 Alcide Jentzer 382 84 00 HOPITAL DE LA TOUR Meyrin 719 61 11 CENTRE MEDICAL DE MEYRIN Champs Fréchets 719 74 00 URGENCES : FIRE BRIGADE 118 FIRE BRIGADE CERN 767 44 44 BESOIN URGENT D'AMBULANCE (GENEVE ET VAUD) : 144 POLICE 117 ANTI-POISON CENTRE 24H/24H 01 251 51 510 EUROPEAN EMERGENCY CALL: 112 FRANCE PATIENT NOT FIT TO BE MOVED: call your family doctor PATIENT CAN BE MOVED: ST. JULIE...

  11. LLNL Yucca Mountain project - near-field environment characterization technical area: Letter report: EQ3/6 version 8: differences from version 7

    Energy Technology Data Exchange (ETDEWEB)

    Wolery, T.J.

    1994-09-29

    EQ3/6 is a software package for geochemical modeling of aqueous systems, such as water/rock or waste/water rock. It is being developed for a variety of applications in geochemical studies for the Yucca Mountain Site Characterization Project. The software has been extensively rewritten for Version 8. The source code has been extensively modernized. The software is now written in Fortran 77 with the most common extensions that are part of the new Fortran 90 standard. The architecture of the software has been improved for better performance and to allow the incorporation of new functional capabilities in Version 8 and planned subsequent versions. In particular, the structure of the major data arrays has been significantly altered and extended. Three new major functional capabilities have been incorporated in Version 8. The first of these allows the treatment of redox disequilibrium in reaction-path modeling. This is a natural extension of the long-running capability of providing for such disequilibrium in static speciation-solubility calculations. Such a capability is important, for example, when dealing with systems containing organic species and certain dissolved gas species. The user defines (and sets the controls for) the components in disequilibrium. Such corrections can now be made if the requisite data are present on a supporting data file. At present, this capability is supported only by the SHV data file, which is based on SUPCRT92. Equilibrium constants and other thermodynamic quantities are correct1961ed for pressures which lie off a standard curve, which is defined on the supporting data file and ordinarily corresponds to 1.013 bar up to IOOC, and the steam/liquid water equilibrium pressure up to 300C. The third new major capability is generic ion exchange option previously developed in prototype in a branch Version 7 level version of EQ3/6 by Brian Viani, Bill Bourcier, and Carol Bruton. This option has been modified to fit into the Version 8 data

  12. Nuclear Criticality Safety Handbook, Version 2. English translation

    International Nuclear Information System (INIS)

    2001-08-01

    The Nuclear Criticality Safety Handbook, Version 2 essentially includes the description of the Supplement Report to the Nuclear Criticality Safety Handbook, released in 1995, into the first version of the Nuclear Criticality Safety Handbook, published in 1988. The following two points are new: (1) exemplifying safety margins related to modeled dissolution and extraction processes, (2) describing evaluation methods and alarm system for criticality accidents. Revision has been made based on previous studies for the chapter that treats modeling the fuel system: e.g., the fuel grain size that the system can be regarded as homogeneous, non-uniformity effect of fuel solution, an burnup credit. This revision has solved the inconsistencies found in the first version between the evaluation of errors found in JACS code system and the criticality condition data that were calculated based on the evaluation. This report is an English translation of the Nuclear Criticality Safety Handbook, Version 2, originally published in Japanese as JAERI 1340 in 1999. (author)

  13. Gridded Species Distribution, Version 1: Global Amphibians Presence Grids

    Data.gov (United States)

    National Aeronautics and Space Administration — The Global Amphibians Presence Grids of the Gridded Species Distribution, Version 1 is a reclassified version of the original grids of amphibian species distribution...

  14. Preface

    Science.gov (United States)

    Mary Beth Adams; Dale W. Cole; Charles B. Davey; Scott H. Chang

    2009-01-01

    This volume represents the proceedings from the 11th North American Forest Soils Conference, held June 22?26, 2008 in Blacksburg, Virginia, USA. The theme for the conference "Forest Soil Science: Celebrating 50 Years of Research on Properties, Processes and Management of Forest Soils" captures the celebratory, but thoughtful, nature of the conference. Forest...

  15. Beyond the Boundary: Science, Industry, and Managing Symbiosis

    Science.gov (United States)

    Hansen, Birgitte Gorm

    2011-01-01

    Whether celebratory or critical, STS research on science-industry relations has focused on the blurring of boundaries and hybridization of codes and practices. However, the vocabulary of boundary and hybrid tends to reify science and industry as separate in the attempt to map their relation. Drawing on interviews with the head of a research center…

  16. Ontology Versioning and Change Detection on the Web

    NARCIS (Netherlands)

    Klein, Michel; Fensel, Dieter; Kiryakov, Atanas; Ognyanov, Damyan

    2002-01-01

    To effectively use ontologies on the Web, it is essential that changes in ontologies are managed well. This paper analyzes the topic of ontology versioning in the context of the Web by looking at the characteristics of the version relation between ontologies and at the identification of online

  17. 21 CFR 290.6 - Spanish-language version of required warning.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Spanish-language version of required warning. 290... (CONTINUED) DRUGS: GENERAL CONTROLLED DRUGS General Provisions § 290.6 Spanish-language version of required... of this drug to any person other than the patient for whom it was prescribed.” The Spanish version of...

  18. International Spinal Cord Injury Core Data Set (version 2.0)

    DEFF Research Database (Denmark)

    Biering-Sørensen, F; DeVivo, M J; Charlifue, S

    2017-01-01

    STUDY DESIGN: The study design includes expert opinion, feedback, revisions and final consensus. OBJECTIVES: The objective of the study was to present the new knowledge obtained since the International Spinal Cord Injury (SCI) Core Data Set (Version 1.0) published in 2006, and describe the adjust......STUDY DESIGN: The study design includes expert opinion, feedback, revisions and final consensus. OBJECTIVES: The objective of the study was to present the new knowledge obtained since the International Spinal Cord Injury (SCI) Core Data Set (Version 1.0) published in 2006, and describe...... the adjustments made in Version 2.0, including standardization of data reporting. SETTING: International. METHODS: Comments received from the SCI community were discussed in a working group (WG); suggestions from the WG were reviewed and revisions were made. All suggested revisions were considered, and a final...... version was circulated for final approval. RESULTS: The International SCI Core Data Set (Version 2.0) consists of 25 variables. Changes made to this version include the deletion of one variable 'Total Days Hospitalized' and addition of two variables 'Date of Rehabilitation Admission' and 'Date of Death...

  19. Validation of the Urdu version of the Epworth Sleepiness Scale.

    Science.gov (United States)

    Surani, Asif Anwar; Ramar, Kannan; Surani, Arif Anwar; Khaliqdina, Jehangir Shehryar; Subramanian, Shyam; Surani, Salim

    2012-09-01

    To translate and validate the Epworth Sleepiness Scale (ESS) for use in Urdu-speaking population. The original Epworth Sleepiness Scale was translated into the Urdu version (ESS-Ur) in three phases - translation and back-translation; committee-based translation; and testing in bilingual individuals. The final was subsequently tested on 89 healthy bilingual subjects between February and April, 2010, to assess the validity of the translation compared to the original version. The subjects were students and employees of Dow University of Health Sciences, Karachi. Both English and Urdu versions of the Epworth Sleepiness Scale were administered to 59 (67%) women and 30 (33%) men. The mean composite Epworth score was 7.53 in English language and 7.7 in the Urdu version (p=0.76). The translated version was found to be highly correlated with the original scale (rho=0.938; pscale's Urdu version as an effective tool for measuring daytime sleepiness in Urdu-speaking population. Future studies assessing the validity of such patients with sleep disorders need to be undertaken.

  20. Amnioinfusion to facilitate external cephalic version after initial failure.

    Science.gov (United States)

    Adama van Scheltema, P N; Feitsma, A H; Middeldorp, J M; Vandenbussche, F P H A; Oepkes, D

    2006-09-01

    To evaluate the effectiveness of antepartum transabdominal amnioinfusion to facilitate external cephalic version after initial failure. Women with a structurally normal fetus in breech lie at term, with a failed external cephalic version and an amniotic fluid index (AFI) less than 15 cm, were asked to participate in our study. After tocolysis with indomethacin, a transabdominal amnioinfusion was performed with an 18G spinal needle. Lactated Ringers solution was infused until the AFI reached 15 cm, with a maximum of 1 L. External cephalic version was performed directly afterward. Seven women participated in the study. The gestational age of the women was between 36(+4) and 38(+3) weeks, and three women were primiparous. The AFI ranged from 4 cm to 13 cm. A median amount of 1,000 mL Ringers solution (range 700-1,000 mL) was infused per procedure. The repeat external cephalic versions after amnioinfusion were not successful in any of the patients. In our experience, amnioinfusion does not facilitate external cephalic version.

  1. Simion 3D Version 6.0 User`s Manual

    Energy Technology Data Exchange (ETDEWEB)

    Dahl, D.A.

    1995-11-01

    The original SIMION was an electrostatic lens analysis and design program developed by D.C. McGilvery at Latrobe University, Bundoora Victoria, Australia, 1977. SIMION for the PC, developed at the Idaho National Engineering Laboratory, shares little more than its name with the original McGilvery version. INEL`s fifth major SIMION release, version 6.0, represents a quantum improvement over previous versions. This C based program can model complex problems using an ion optics workbench that can hold up to 200 2D and/or 3D electrostatic/magnetic potential arrays. Arrays can have up to 10,000,000 points. SIMION 3D`s 32 bit virtual Graphics User Interface provides a highly interactive advanced user environment. All potential arrays are visualized as 3D objects that the user can cut away to inspect ion trajectories and potential energy surfaces. User programs have been greatly extended in versatility and power. A new geometry file option supports the definition of highly complex array geometry. Extensive algorithm modifications have dramatically improved this version`s computational speed and accuracy.

  2. Against Amateur Economies: Spec Work Competitions and the Anti-spec Movement

    Directory of Open Access Journals (Sweden)

    Helen Kennedy

    2013-04-01

    Full Text Available The rise and rise of the amateur cultural producer has been greeted with a spectacular amount of celebratory rhetoric, in both popular and academic writing . It has also been criticised, often for the inferior quality of amateur productions compared to the fruits of professional labour. But apart from that by a small number of journalism scholars, little empirical research has been carried out with professional creative labourers about the impact of amateur economies on their work, and their responses to amateur production practices. This article addresses that gap, and also counterbalances the dominant celebratory discourse by focusing on an initiative that is critical of amateur economies and that emerges from creative workers themselves: the anti-spec movement within design industries. Anti-spec activists campaign against speculative (or spec work, which is seen as one problematic materialisation of crowdsourced, amateur economies. Here, it is argued that responses to spec work can be understood in relation to designers’ ethics and values and the extent to which they feel that these are thrown into question by amateur activity.

  3. Version control with Git

    CERN Document Server

    Loeliger, Jon

    2012-01-01

    Get up to speed on Git for tracking, branching, merging, and managing code revisions. Through a series of step-by-step tutorials, this practical guide takes you quickly from Git fundamentals to advanced techniques, and provides friendly yet rigorous advice for navigating the many functions of this open source version control system. This thoroughly revised edition also includes tips for manipulating trees, extended coverage of the reflog and stash, and a complete introduction to the GitHub repository. Git lets you manage code development in a virtually endless variety of ways, once you understand how to harness the system's flexibility. This book shows you how. Learn how to use Git for several real-world development scenarios ; Gain insight into Git's common-use cases, initial tasks, and basic functions ; Use the system for both centralized and distributed version control ; Learn how to manage merges, conflicts, patches, and diffs ; Apply advanced techniques such as rebasing, hooks, and ways to handle submodu...

  4. Labour Outcomes After Successful External Cephalic Version Compared With Spontaneous Cephalic Version.

    Science.gov (United States)

    Krueger, Samantha; Simioni, Julia; Griffith, Lauren E; Hutton, Eileen K

    2018-01-01

    This study sought to compare obstetrical outcomes for women with a cephalic presentation at birth resulting from successful external cephalic version (ECV) compared to those resulting from spontaneous cephalic version (SCV). Secondary analysis was performed on Early External Cephalic Version Trial data. A total of 931 study participants had breech presentations between 34 and 36 weeks' gestation and cephalic presentations at birth. The incidence of intrapartum interventions was compared between patients with successful ECV (557) and those with SCV (374). A generalized linear mixed model was used to determine ORs for our primary outcomes. Parity, maternal BMI, previous CS, and enrolment centre were controlled for in the analysis. No differences were found after ECV compared with SCV in the incidence of CS (96 of 557 and 76 of 374, respectively; adjusted OR [aOR] 0.89; 95% CI 0.63-1.26), instrumental birth (68 of 557 and 29 of 373, respectively; aOR 1.55; 95% CI 0.96-2.50), or normal vaginal birth (393 of 557 and 268 of 373, respectively; aOR 0.92; 95% CI 0.68-1.24). Multiparous women with successful ECV were half as likely to require a CS compared with those with SCV and no ECV (28 of 313 and 42 of 258, respectively; aOR 0.45; 95% CI 0.26-0.80). This is the first study to compare birth outcomes of breech pregnancies that convert to cephalic presentation by means of SCV with birth outcomes of breech pregnancies that have ECV. Women with a cephalic-presenting fetus at birth as a result of successful ECV are not at greater risk of obstetrical interventions at birth when compared with women with fetuses who spontaneously turn to a cephalic presentation in the third trimester. Copyright © 2018. Published by Elsevier Inc.

  5. Portuguese version of the PTSD Checklist-Military Version (PCL-M)-I: Confirmatory Factor Analysis and reliability.

    Science.gov (United States)

    Carvalho, Teresa; Cunha, Marina; Pinto-Gouveia, José; Duarte, Joana

    2015-03-30

    The PTSD Checklist-Military Version (PCL-M) is a brief self-report instrument widely used to assess Post-traumatic Stress Disorder (PTSD) symptomatology in war Veterans, according to DSM-IV. This study sought out to explore the factor structure and reliability of the Portuguese version of the PCL-M. A sample of 660 Portuguese Colonial War Veterans completed the PCL-M. Several Confirmatory Factor Analyses were conducted to test different structures for PCL-M PTSD symptoms. Although the respecified first-order four-factor model based on King et al.'s model showed the best fit to the data, the respecified first and second-order models based on the DSM-IV symptom clusters also presented an acceptable fit. In addition, the PCL-M showed adequate reliability. The Portuguese version of the PCL-M is thus a valid and reliable measure to assess the severity of PTSD symptoms as described in DSM-IV. Its use with Portuguese Colonial War Veterans may ease screening of possible PTSD cases, promote more suitable treatment planning, and enable monitoring of therapeutic outcomes. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Model Adequacy Analysis of Matching Record Versions in Nosql Databases

    Directory of Open Access Journals (Sweden)

    E. V. Tsviashchenko

    2015-01-01

    Full Text Available The article investigates a model of matching record versions. The goal of this work is to analyse the model adequacy. This model allows estimating a user’s processing time distribution of the record versions and a distribution of the record versions count. The second option of the model was used, according to which, for a client the time to process record versions depends explicitly on the number of updates, performed by the other users between the sequential updates performed by a current client. In order to prove the model adequacy the real experiment was conducted in the cloud cluster. The cluster contains 10 virtual nodes, provided by DigitalOcean Company. The Ubuntu Server 14.04 was used as an operating system (OS. The NoSQL system Riak was chosen for experiments. In the Riak 2.0 version and later provide “dotted vector versions” (DVV option, which is an extension of the classic vector clock. Their use guarantees, that the versions count, simultaneously stored in DB, will not exceed the count of clients, operating in parallel with a record. This is very important while conducting experiments. For developing the application the java library, provided by Riak, was used. The processes run directly on the nodes. In experiment two records were used. They are: Z – the record, versions of which are handled by clients; RZ – service record, which contains record update counters. The application algorithm can be briefly described as follows: every client reads versions of the record Z, processes its updates using the RZ record counters, and saves treated record in database while old versions are deleted form DB. Then, a client rereads the RZ record and increments counters of updates for the other clients. After that, a client rereads the Z record, saves necessary statistics, and deliberates the results of processing. In the case of emerging conflict because of simultaneous updates of the RZ record, the client obtains all versions of that

  7. New developments in program STANSOL version 3

    International Nuclear Information System (INIS)

    Gray, W.H.

    1981-10-01

    STANSOL is a computer program that applied a solution for the mechanical displacement, stress, and strain in rotationally-transversely isotropic, homogeneous, axisymmetric solenoids. Careful application of the solution permits the complex mechanical behavior of multilayered, nonhomogeneous solenoids to be examined in which the loads may vary arbitrarily from layer to layer. Loads applied to the solenoid model by program STANSOL may consist of differential temperature, winding preload, internal and/or external surface pressure, and electromagnetic Lorentz body forces. STANSOL version 3, the latest update to the original version of the computer program, also permits structural analysis of solenoid magnets in which frictionless interlayer gaps may open or close. This paper presents the new theory coded into version 3 of the STANSOL program, as well as the new input data format and graphical output display of the resulting analysis

  8. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION WITH CLIPSITS)

    Science.gov (United States)

    Riley, , .

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh

  9. HECTR [Hydrogen Event Containment Transient Response] Version 1.5N: A modification of HECTR Version 1.5 for application to N Reactor

    International Nuclear Information System (INIS)

    Camp, A.L.; Dingman, S.E.

    1987-05-01

    This report describes HECTR Version 1.5N, which is a special version of HECTR developed specifically for application to the N Reactor. HECTR is a fast-running, lumped-parameter containment analysis computer program that is most useful for performing parametric studies. The main purpose of HECTR is to analyze nuclear reactor accidents involving the transport and combustion of hydrogen, but HECTR can also function as an experiment analysis tool and can solve a limited set of other types of containment problems. Version 1.5N is a modification of Version 1.5 and includes changes to the spray actuation logic, and models for steam vents, vacuum breakers, and building cross-vents. Thus, all of the key features of the N Reactor confinement can be modeled. HECTR is designed for flexibility and provides for user control of many important parameters, if built-in correlations and default values are not desired

  10. Global Historical Climatology Network - Monthly (GHCN-M), Version 2

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note, the temperature portion of this dataset has been superseded by a newer version. Users should not use this version except in rare cases (e.g., when...

  11. Integrated Global Radiosonde Archive (IGRA) - Monthly Means (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note, this dataset has been superseded by a newer version (see below). Users should not use this version except in rare cases (e.g., when reproducing previous...

  12. "Oh, She's so Smart": Girls' Complex Engagements with Post/Feminist Narratives of Academic Success

    Science.gov (United States)

    Pomerantz, Shauna; Raby, Rebecca

    2011-01-01

    This article explores how six teenage girls talk about being smart in the wake of celebratory discourses touting gender equality in education and beyond. Set against the neo-liberal backdrop of "What about the boys?" and "girl power", it is assumed that smart girls today "have it all" and, therefore, no longer require feminist interventions in the…

  13. [The Confusion Assessment Method: Transcultural adaptation of a French version].

    Science.gov (United States)

    Antoine, V; Belmin, J; Blain, H; Bonin-Guillaume, S; Goldsmith, L; Guerin, O; Kergoat, M-J; Landais, P; Mahmoudi, R; Morais, J A; Rataboul, P; Saber, A; Sirvain, S; Wolfklein, G; de Wazieres, B

    2018-04-03

    The Confusion Assessment Method (CAM) is a validated key tool in clinical practice and research programs to diagnose delirium and assess its severity. There is no validated French version of the CAM training manual and coding guide (Inouye SK). The aim of this study was to establish a consensual French version of the CAM and its manual. Cross-cultural adaptation to achieve equivalence between the original version and a French adapted version of the CAM manual. A rigorous process was conducted including control of cultural adequacy of the tool's components, double forward and back translations, reconciliation, expert committee review (including bilingual translators with different nationalities, a linguist, highly qualified clinicians, methodologists) and pretesting. A consensual French version of the CAM was achieved. Implementation of the CAM French version in daily clinical practice will enable optimal diagnosis of delirium diagnosis and enhance communication between health professionals in French speaking countries. Validity and psychometric properties are being tested in a French multicenter cohort, opening up new perspectives for improved quality of care and research programs in French speaking countries. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  14. Preliminary site description Forsmark area - version 1.1

    International Nuclear Information System (INIS)

    2004-03-01

    This report presents the interim version (model version 1.1) of the preliminary Site Descriptive Model for Forsmark. The basis for this interim version is quality-assured, geoscientific and ecological field data from Forsmark that were available in the SKB databases SICADA and GIS at April 30, 2003 as well as version 0 of the Site Descriptive Model. The new data acquired during the initial site investigation phase to the date of data freeze 1.1 constitute the basis for the updating of version 0 to version 1.1. These data originate from surface investigations on the candidate area with its regional environment and from drilling and investigations in boreholes. The surface-based data sets were rather extensive whereas the data sets from boreholes were limited to information from one 1,000 m deep cored borehole (KFM01A) and eight 150 to 200 m deep percussion-drilled boreholes in the Forsmark candidate area. Discipline specific models are developed for a selected regional and local model volume and these are then integrated into a site description. The current methodologies for developing the discipline specific models and the integration of these are documented in methodology reports or strategy reports. In the present work, the guidelines given in those reports were followed to the extent possible with the data and information available at the time for data freeze for model version 1.1. Compared with version 0 there are considerable additional features in the version 1.1, especially in the geological description and in the description of the near surface. The geological models of lithology and deformation zones are based on borehole information and much higher resolution surface data. The existence of highly fractured sub-horizontal zones has been verified and these are now part of the model of the deformation zones. A discrete fracture network (DFN) model has also been developed. The rock mechanics model is based on strength information from SFR and an empirical

  15. National Radiobiology Archives Distributed Access User's Manual, Version 1. 1

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.K.; Prather, J.C.; Ligotke, E.K.; Watson, C.R.

    1992-06-01

    This supplement to the NRA Distributed Access User's manual (PNL-7877), November 1991, describes installation and use of Version 1.1 of the software package; this is not a replacement of the previous manual. Version 1.1 of the NRA Distributed Access Package is a maintenance release. It eliminates several bugs, and includes a few new features which are described in this manual. Although the appearance of some menu screens has changed, we are confident that the Version 1.0 User's Manual will provide an adequate introduction to the system. Users who are unfamiliar with Version 1.0 may wish to experiment with that version before moving on to Version 1.1.

  16. The effects of FreeSurfer version, workstation type, and Macintosh operating system version on anatomical volume and cortical thickness measurements.

    Science.gov (United States)

    Gronenschild, Ed H B M; Habets, Petra; Jacobs, Heidi I L; Mengelers, Ron; Rozendaal, Nico; van Os, Jim; Marcelis, Machteld

    2012-01-01

    FreeSurfer is a popular software package to measure cortical thickness and volume of neuroanatomical structures. However, little if any is known about measurement reliability across various data processing conditions. Using a set of 30 anatomical T1-weighted 3T MRI scans, we investigated the effects of data processing variables such as FreeSurfer version (v4.3.1, v4.5.0, and v5.0.0), workstation (Macintosh and Hewlett-Packard), and Macintosh operating system version (OSX 10.5 and OSX 10.6). Significant differences were revealed between FreeSurfer version v5.0.0 and the two earlier versions. These differences were on average 8.8 ± 6.6% (range 1.3-64.0%) (volume) and 2.8 ± 1.3% (1.1-7.7%) (cortical thickness). About a factor two smaller differences were detected between Macintosh and Hewlett-Packard workstations and between OSX 10.5 and OSX 10.6. The observed differences are similar in magnitude as effect sizes reported in accuracy evaluations and neurodegenerative studies.The main conclusion is that in the context of an ongoing study, users are discouraged to update to a new major release of either FreeSurfer or operating system or to switch to a different type of workstation without repeating the analysis; results thus give a quantitative support to successive recommendations stated by FreeSurfer developers over the years. Moreover, in view of the large and significant cross-version differences, it is concluded that formal assessment of the accuracy of FreeSurfer is desirable.

  17. The effects of FreeSurfer version, workstation type, and Macintosh operating system version on anatomical volume and cortical thickness measurements.

    Directory of Open Access Journals (Sweden)

    Ed H B M Gronenschild

    Full Text Available FreeSurfer is a popular software package to measure cortical thickness and volume of neuroanatomical structures. However, little if any is known about measurement reliability across various data processing conditions. Using a set of 30 anatomical T1-weighted 3T MRI scans, we investigated the effects of data processing variables such as FreeSurfer version (v4.3.1, v4.5.0, and v5.0.0, workstation (Macintosh and Hewlett-Packard, and Macintosh operating system version (OSX 10.5 and OSX 10.6. Significant differences were revealed between FreeSurfer version v5.0.0 and the two earlier versions. These differences were on average 8.8 ± 6.6% (range 1.3-64.0% (volume and 2.8 ± 1.3% (1.1-7.7% (cortical thickness. About a factor two smaller differences were detected between Macintosh and Hewlett-Packard workstations and between OSX 10.5 and OSX 10.6. The observed differences are similar in magnitude as effect sizes reported in accuracy evaluations and neurodegenerative studies.The main conclusion is that in the context of an ongoing study, users are discouraged to update to a new major release of either FreeSurfer or operating system or to switch to a different type of workstation without repeating the analysis; results thus give a quantitative support to successive recommendations stated by FreeSurfer developers over the years. Moreover, in view of the large and significant cross-version differences, it is concluded that formal assessment of the accuracy of FreeSurfer is desirable.

  18. NOAA Climate Data Record (CDR) of GPS RO-Calibrated AMSU Channel 9 (Temperatures in the Lower Stratosphere,TLS), Version 1.0 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note, this dataset has been superseded by a newer version (see below). Users should not use this version except in rare cases (e.g., when reproducing previous...

  19. NOAA Climate Data Record (CDR) of GPS RO-Calibrated AMSU Channel 9 (Temperatures in the Lower Stratosphere,TLS), Version 1.1 (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note, this dataset has been superseded by a newer version (see below). Users should not use this version except in rare cases (e.g., when reproducing previous...

  20. Interactive tag cloud visualization of software version control repositories

    CSIR Research Space (South Africa)

    Greene, GJ

    2015-09-01

    Full Text Available Version control repositories contain a wealth of implicit information that can be used to answer many questions about a project’s development process. However, this information is not directly accessible in the version control archives and must...

  1. What Industry Is Saying About the Battery ISC Device (Text Version) |

    Science.gov (United States)

    version of the video What Industry Is Saying About the Battery ISC Device. Bring Up NREL Logo with Music Transportation Research | NREL What Industry Is Saying About the Battery ISC Device (Text Version) What Industry Is Saying About the Battery ISC Device (Text Version) The following is the text

  2. A kernel version of multivariate alteration detection

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Vestergaard, Jacob Schack

    2013-01-01

    Based on the established methods kernel canonical correlation analysis and multivariate alteration detection we introduce a kernel version of multivariate alteration detection. A case study with SPOT HRV data shows that the kMAD variates focus on extreme change observations.......Based on the established methods kernel canonical correlation analysis and multivariate alteration detection we introduce a kernel version of multivariate alteration detection. A case study with SPOT HRV data shows that the kMAD variates focus on extreme change observations....

  3. Regularization Tools Version 3.0 for Matlab 5.2

    DEFF Research Database (Denmark)

    Hansen, Per Christian

    1999-01-01

    This communication describes Version 3.0 of Regularization Tools, a Matlab package for analysis and solution of discrete ill-posed problems.......This communication describes Version 3.0 of Regularization Tools, a Matlab package for analysis and solution of discrete ill-posed problems....

  4. Tocolysis in term breech external cephalic version.

    Science.gov (United States)

    Nor Azlin, M I; Haliza, H; Mahdy, Z A; Anson, I; Fahya, M N; Jamil, M A

    2005-01-01

    To study the effect of ritodrine tocolysis on the success of external cephalic version (ECV) and to assess the role of ECV in breech presentation at our centre. A prospective randomized double-blind-controlled trial comparing ritodrine and placebo in ECV of singleton term breech pregnancy at a tertiary hospital. Among the 60 patients who were recruited, there was a success rate of 36.7%. Ritodrine tocolysis significantly improved the success rate of ECV (50% vs. 23%; P=0.032). There was a marked effect of ritodrine tocolysis on the ECV success in nulliparae (36.4% vs. 13.0%) and multiparae (87.5% vs. 57.1%). External cephalic version has shown to reduce the rate of cesarean section for breech presentation by 33.5% in our unit. External cephalic version significantly reduced the rate of cesarean section in breech presentation, and ritodrine tocolysis improved the success of ECV and should be offered to both nulliparous and parous women in the case of term breech presentation.

  5. New Open-Source Version of FLORIS Released | News | NREL

    Science.gov (United States)

    New Open-Source Version of FLORIS Released New Open-Source Version of FLORIS Released January 26 , 2018 National Renewable Energy Laboratory (NREL) researchers recently released an updated open-source simplified and documented. Because of the living, open-source nature of the newly updated utility, NREL

  6. Disability assessment scale for dementia – long version (DADL-BR

    Directory of Open Access Journals (Sweden)

    Mariana Boaro Fernandez Canon

    2016-04-01

    Full Text Available Introduction: There are no functional assessment tools for elderly with dementia available in the literature that will assess all occupations. Objective: To develop a Long Version of Disability Assessment for Dementia Scale (DADL-Br, covering all occupations provided by the American Association of Occupational Therapy (AOTA and the activities that compose them and evaluate its content validity. Method: With the permission of the original version main author (DAD, Isabelle Gélinas PhD, the new items of the Long Version (DADL-Br were developed based on the classification proposed by AOTA for occupations, considering the gaps in the original instrument. We reviewed the Cultural and Conceptual Equivalence by the Expert Committee and Multidisciplinary Committee. The suggestions of the Committees were accepted and the process followed for the pre-test and author analysis. Results: The first version of the instrument received 10 new fields and 64 new items, which after seven reviews of Cultural Equivalence (average concordance 89.2%, six reviews of Conceptual Equivalence (average concordance 81.2%, tree pre-tests and analysis of the original version main author, has resulted in the development of five versions, addition of twelve items and exclusion of seven items, and the final version consists of 20 fields and 109 items, being 10 new fields and 69 new items. Conclusion: This process conferred the content validity of DADL-Br, which includes all occupations proposed by AOTA and can be a useful tool to evaluate the profile of occupational performance of elderly with dementia.

  7. RASCAL Version 2.0 workbook

    International Nuclear Information System (INIS)

    Athey, G.F.; McKenna, T.J.

    1993-05-01

    The Radiological Assessment System for Consequence Analysis, Version 2.0 (RASCAL 2.0) has been developed for use by the NRC personnel who respond to radiological emergencies. This workbook is intended to complement the RASCAL 2.0 User's Guide (NUREG/CR-5247, Vol. 1). The workbook contains exercises designed to familiarize the user with the computer based tools of RASCAL through hands-on problem solving. The workbook is composed of four major sections. The first part is a RASCAL familiarization exercise to acquaint the user with the operation of the forms, menus, on-line help, and documentation. The latter three parts contain exercises in using the three tools of RASCAL Version 2.0: DECAY, FM-DOSE, and ST-DOSE. Each section of exercises is followed by discussion on how the tools could be used to solve the problem

  8. Revised Reading the Mind in the Eyes Test (RMET - Brazilian version

    Directory of Open Access Journals (Sweden)

    Breno Sanvicente-Vieira

    2014-03-01

    Full Text Available Objective: To translate and adapt to Brazilian Portuguese the Revised Reading the Mind in the Eyes Test (RMET, in both paper-and-pencil and computerized versions. The RMET is a well-accepted instrument for assessment of Theory of Mind (ToM, an important component of social cognition. Methods: Following a guideline for translation of material for clinical populations, this study had three main phases: 1 formal translation and semantic adaptation to Brazilian Portuguese; 2 an acceptability trial with health professionals as judges evaluating picture-word matching; and 3 a trial using the paper-and-pencil and computerized versions (experiments built in E-Prime 2.0.10 software with healthy participants to test whether the instrument has similar outputs to those expected in versions in other languages. Results: RMET was adequately adapted to Brazilian Portuguese. This version showed acceptability and outputs similar to versions of the instrument in other languages, including the original one. We kept the same number of images as the original English version. Conclusions: Considering the scarcity of cognitive assessment instruments adequately adapted to Portuguese and the importance of social cognition in many psychiatric disorders, this work adds an important resource to Brazilian research and is administrable in both paper-and-pencil and computerized versions.

  9. Preliminary site description Forsmark area - version 1.1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-03-01

    This report presents the interim version (model version 1.1) of the preliminary Site Descriptive Model for Forsmark. The basis for this interim version is quality-assured, geoscientific and ecological field data from Forsmark that were available in the SKB databases SICADA and GIS at April 30, 2003 as well as version 0 of the Site Descriptive Model. The new data acquired during the initial site investigation phase to the date of data freeze 1.1 constitute the basis for the updating of version 0 to version 1.1. These data originate from surface investigations on the candidate area with its regional environment and from drilling and investigations in boreholes. The surface-based data sets were rather extensive whereas the data sets from boreholes were limited to information from one 1,000 m deep cored borehole (KFM01A) and eight 150 to 200 m deep percussion-drilled boreholes in the Forsmark candidate area. Discipline specific models are developed for a selected regional and local model volume and these are then integrated into a site description. The current methodologies for developing the discipline specific models and the integration of these are documented in methodology reports or strategy reports. In the present work, the guidelines given in those reports were followed to the extent possible with the data and information available at the time for data freeze for model version 1.1. Compared with version 0 there are considerable additional features in the version 1.1, especially in the geological description and in the description of the near surface. The geological models of lithology and deformation zones are based on borehole information and much higher resolution surface data. The existence of highly fractured sub-horizontal zones has been verified and these are now part of the model of the deformation zones. A discrete fracture network (DFN) model has also been developed. The rock mechanics model is based on strength information from SFR and an empirical

  10. The Hamburg Oceanic Carbon Cycle Circulation Model. Version 1. Version 'HAMOCC2s' for long time integrations

    Energy Technology Data Exchange (ETDEWEB)

    Heinze, C.; Maier-Reimer, E. [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany)

    1999-11-01

    The Hamburg Ocean Carbon Cycle Circulation Model (HAMOCC, configuration HAMOCC2s) predicts the atmospheric carbon dioxide partial pressure (as induced by oceanic processes), production rates of biogenic particulate matter, and geochemical tracer distributions in the water column as well as the bioturbated sediment. Besides the carbon cycle this model version includes also the marine silicon cycle (silicic acid in the water column and the sediment pore waters, biological opal production, opal flux through the water column and opal sediment pore water interaction). The model is based on the grid and geometry of the LSG ocean general circulation model (see the corresponding manual, LSG=Large Scale Geostrophic) and uses a velocity field provided by the LSG-model in 'frozen' state. In contrast to the earlier version of the model (see Report No. 5), the present version includes a multi-layer sediment model of the bioturbated sediment zone, allowing for variable tracer inventories within the complete model system. (orig.)

  11. Mediation analysis with multiple versions of the mediator.

    Science.gov (United States)

    Vanderweele, Tyler J

    2012-05-01

    The causal inference literature has provided definitions of direct and indirect effects based on counterfactuals that generalize the approach found in the social science literature. However, these definitions presuppose well-defined hypothetical interventions on the mediator. In many settings, there may be multiple ways to fix the mediator to a particular value, and these various hypothetical interventions may have very different implications for the outcome of interest. In this paper, we consider mediation analysis when multiple versions of the mediator are present. Specifically, we consider the problem of attempting to decompose a total effect of an exposure on an outcome into the portion through the intermediate and the portion through other pathways. We consider the setting in which there are multiple versions of the mediator but the investigator has access only to data on the particular measurement, not information on which version of the mediator may have brought that value about. We show that the quantity that is estimated as a natural indirect effect using only the available data does indeed have an interpretation as a particular type of mediated effect; however, the quantity estimated as a natural direct effect, in fact, captures both a true direct effect and an effect of the exposure on the outcome mediated through the effect of the version of the mediator that is not captured by the mediator measurement. The results are illustrated using 2 examples from the literature, one in which the versions of the mediator are unknown and another in which the mediator itself has been dichotomized.

  12. MATLAB Software Versions and Licenses for the Peregrine System |

    Science.gov (United States)

    High-Performance Computing | NREL MATLAB Software Versions and Licenses for the Peregrine System MATLAB Software Versions and Licenses for the Peregrine System Learn about the MATLAB software Peregrine is R2017b. Licenses MATLAB is proprietary software. As such, users have access to a limited number

  13. ADAMS/WT advanced development - version 1.4 and beyond

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, A.S.; Depauw, T.R. [Mechanical Dynamics, Inc., Mesa, AZ (United States)

    1996-12-31

    ADAMS/WT is an wind-turbine-specific shell for the general-purpose mechanical system simulation package ADAMS5. It was developed under the guidance of the National Renewable Energy Laboratory to give engineers and analysts in the wind turbine community access to the analytical power of ADAMS, without having to become expert in its particular technology. The 1.4 version of ADAMS/WT is the most recent upgrade to the package, incorporating the most up-to-date version of the AeroDyn aerodynamic forcing subroutines from the University of Utah. It is also the first version to be made available on the Windows/NT platform. In version 1.4, ADAMS/WT has been significantly improved throughout and runs much faster. Automatic generation of standardized output has been added. The documentation has been extensively augmented with more detailed descriptions, more figures and more examples. ADAMS/WT remains the most powerful analytical tool available for horizontal-axis wind turbine development. 10 figs.

  14. RELAP5/MOD1-EUR evaluation. Comparison with the INEL original version

    International Nuclear Information System (INIS)

    Mazzantini, O.A.

    1990-01-01

    In this work, the values calculated from two versions of the RELAP5/MOD1 code are compared with those measured in different tests. The first version of RELAP5 is the cycle 19 of the original version of INEL (RELAP5/MOD1-INEL) and the second version improved by EURATOM (RELAP5/MOD1-EUR) which was transferred to ENACE through agreements made with SIEMENS/KWU. (Author) [es

  15. Version E2 from Dimco-System for the statistical calculation of components

    International Nuclear Information System (INIS)

    Moreno Gonzalez, A.

    1981-01-01

    A short description of the general system Dimco, together with a detailed description of E2 version are presented. E2 version is a two-dimensional finite element structural code. To illustrate the posibilities of E2 version, some results obtained with this new version are presented. These results are related with the following behaviour of the material: a) elastic, b) thermo-elastic, c) Plastic and d) creep. (author)

  16. Finding the breech: Influence of breech presentation on mode of delivery based on timing of diagnosis, attempt at external cephalic version, and provider success with version.

    Science.gov (United States)

    Andrews, Suzanne; Leeman, Lawrence; Yonke, Nicole

    2017-09-01

    Breech presentation affects 3-4% of pregnancies at term and malpresentation is the primary indication for 10-15% of cesarean deliveries. External cephalic version is an effective intervention that can decrease the need for cesarean delivery; however, timely identification of breech presentation is required. We hypothesized that women with a fetus in a breech presentation that is diagnosed after 38 weeks' estimated gestational age have a decreased likelihood of external cephalic version attempted and an increased likelihood of cesarean delivery. This was a retrospective cohort study. A chart review was performed for 251 women with breech presentation at term presenting to our tertiary referral university hospital for external cephalic version, cesarean for breech presentation, or vaginal breech delivery. Vaginal delivery was significantly more likely (31.1% vs 12.5%; Pexternal cephalic version was offered, and subsequently attempted in a greater proportion of women diagnosed before 38 weeks. External cephalic version was more successful when performed by physicians with greater procedural volume during the 3.5 year period of the study (59.1% for providers performing at least 10 procedures vs 31.3% if performing fewer than 10 procedures, Pexternal cephalic version. © 2017 Wiley Periodicals, Inc.

  17. Vietnamese validation of the short version of Internet Addiction Test

    OpenAIRE

    Tran, Bach Xuan; Mai, Hue Thi; Nguyen, Long Hoang; Nguyen, Cuong Tat; Latkin, Carl A.; Zhang, Melvyn W.B.; Ho, Roger C.M.

    2017-01-01

    Background and aims: The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT) and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. Methods: The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analys...

  18. User's Manual for LEWICE Version 3.2

    Science.gov (United States)

    Wright, William

    2008-01-01

    A research project is underway at NASA Glenn to produce a computer code which can accurately predict ice growth under a wide range of meteorological conditions for any aircraft surface. This report will present a description of the code inputs and outputs from version 3.2 of this software, which is called LEWICE. This version differs from release 2.0 due to the addition of advanced thermal analysis capabilities for de-icing and anti-icing applications using electrothermal heaters or bleed air applications, the addition of automated Navier-Stokes analysis, an empirical model for supercooled large droplets (SLD) and a pneumatic boot option. An extensive effort was also undertaken to compare the results against the database of electrothermal results which have been generated in the NASA Glenn Icing Research Tunnel (IRT) as was performed for the validation effort for version 2.0. This report will primarily describe the features of the software related to the use of the program. Appendix A has been included to list some of the inner workings of the software or the physical models used. This information is also available in the form of several unpublished documents internal to NASA. This report is intended as a replacement for all previous user manuals of LEWICE. In addition to describing the changes and improvements made for this version, information from previous manuals may be duplicated so that the user will not need to consult previous manuals to use this software.

  19. Assessing Reliability of Two Versions of Vocabulary Levels Tests in Iranian Context

    Directory of Open Access Journals (Sweden)

    Aso Bayazidi

    2017-02-01

    Full Text Available This study examined the equivalence and reliability of the two versions of the Vocabulary Levels Test in an Iranian context. This study was motivated by the fact that the Vocabulary Levels test is increasingly being used in Iran for both research and pedagogical purposes without having been checked for validity and reliability in this context. The equivalence and reliability of the two versions of the test were examined through the parallel-form approach to reliability in Classical True Score theory. Seventy-five intermediate learners of English as a foreign language at the Iran Language Institute took the two versions of the test with one week interval between the two administrations in a counterbalanced fashion. To examine the equivalence of the two versions, the means and variances of the scores obtained for the two tests were compared using paired-sample t-test and one-way ANOVA, respectively. The results of the analyses indicated that the difference between the means of the two versions was significant, and the two versions cannot be considered as parallel forms. To assess the reliability of the two versions, the correlation between the scores obtained from them was estimated using Pearson Product Moment correlation. The results of the analyses showed that the two versions are highly correlated and are reliable tests. It is concluded that the two versions should not be treated as equivalent in longitudinal and gain score studies.

  20. Validation of the Turkish Version of the Cognitive Test Anxiety Scale–Revised

    Directory of Open Access Journals (Sweden)

    Sati Bozkurt

    2017-01-01

    Full Text Available The current study explored the psychometric properties of the newly designed Turkish version of the Cognitive Test Anxiety Scale–Revised (CTAR. Results of an exploratory factor analysis revealed an unidimensional structure consistent with the conceptualized nature of cognitive test anxiety and previous examinations of the English version of the CTAR. Examination of the factor loadings revealed two items that were weakly related to the test anxiety construct and as such were prime candidates for removal. Confirmatory factor analyses were conducted to compare model fit for the 25- and 23-item version of the measure. Results indicated that the 23-item version of the measure provided a better fit to the data which support the removal of the problematic items in the Turkish version of the CTAR. Additional analyses demonstrated the internal consistency, test–retest reliability, concurrent validity, and gender equivalence for responses offered on the Turkish version of the measure. Results of the analysis revealed a 23-item Turkish version of the T-CTAR is a valid and reliable measure of cognitive test anxiety for use among Turkish students.

  1. An Improved Version of TOPAZ 3D

    International Nuclear Information System (INIS)

    Krasnykh, Anatoly

    2003-01-01

    An improved version of the TOPAZ 3D gun code is presented as a powerful tool for beam optics simulation. In contrast to the previous version of TOPAZ 3D, the geometry of the device under test is introduced into TOPAZ 3D directly from a CAD program, such as Solid Edge or AutoCAD. In order to have this new feature, an interface was developed, using the GiD software package as a meshing code. The article describes this method with two models to illustrate the results

  2. A kernel version of spatial factor analysis

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg

    2009-01-01

    . Schölkopf et al. introduce kernel PCA. Shawe-Taylor and Cristianini is an excellent reference for kernel methods in general. Bishop and Press et al. describe kernel methods among many other subjects. Nielsen and Canty use kernel PCA to detect change in univariate airborne digital camera images. The kernel...... version of PCA handles nonlinearities by implicitly transforming data into high (even infinite) dimensional feature space via the kernel function and then performing a linear analysis in that space. In this paper we shall apply kernel versions of PCA, maximum autocorrelation factor (MAF) analysis...

  3. The Mars Climate Database (MCD version 5.2)

    Science.gov (United States)

    Millour, E.; Forget, F.; Spiga, A.; Navarro, T.; Madeleine, J.-B.; Montabone, L.; Pottier, A.; Lefevre, F.; Montmessin, F.; Chaufray, J.-Y.; Lopez-Valverde, M. A.; Gonzalez-Galindo, F.; Lewis, S. R.; Read, P. L.; Huot, J.-P.; Desjean, M.-C.; MCD/GCM development Team

    2015-10-01

    The Mars Climate Database (MCD) is a database of meteorological fields derived from General Circulation Model (GCM) numerical simulations of the Martian atmosphere and validated using available observational data. The MCD includes complementary post-processing schemes such as high spatial resolution interpolation of environmental data and means of reconstructing the variability thereof. We have just completed (March 2015) the generation of a new version of the MCD, MCD version 5.2

  4. The self-report Version of the LSAS-CA: Psychometric Properties of the French Version in a non-clinical adolescent sample

    Directory of Open Access Journals (Sweden)

    Emilie Schmits

    2014-02-01

    Full Text Available The Liebowitz Social Anxiety Scale (LSAS is one of the most popular measures of social anxiety in adults. The LSAS has been adapted for clinical assessment of children and adolescents (LSAS-CA. The psychometric properties of the self-report version of the LSAS-CA (LSAS-CA-SR have been investigated in a Spanish population. However, no study to date has adapted and validated this scale in French. The purpose of this study was to develop a French version of the LSAS-CA-SR and to assess its score reliability and structural validity in a French-speaking community sample. The sample was made up of 1,343 teenagers from secondary schools, aged between 14 and 18 years. Confirmatory factor analyses established the structural validity of the French version of the LSAS-CA-SR and good psychometric properties, including reliable internal consistency, were observed.

  5. Cross-cultural adaptation of the Brazilian version of the Vocal Fatigue Index - VFI.

    Science.gov (United States)

    Zambon, Fabiana; Moreti, Felipe; Nanjundeswaran, Chayadevie; Behlau, Mara

    2017-03-13

    The purpose of this study was to perform the cultural adaptation of the Brazilian version of the Vocal Fatigue Index (VFI). Two Brazilian bilingual speech-language pathologists (SLP) translated the original version of the VFI in English into Portuguese. The translations were reviewed by a committee of five voice specialist SLPs resulting in the final version of the instrument. A third bilingual SLP back-translated this final version and the same committee reviewed the differences from its original version. The final Portuguese version of the VFI, as in the original English version, was answered on a categorical scale of 0-4 indicating the frequency they experience the symptoms: 0=never, 1=almost never, 2=sometimes, 3=almost always, and 4=always. For cultural equivalence of the Portuguese version, the option "not applicable" was added to the categorical scale and 20 individuals with vocal complaints and dysphonia completed the index. Questions considered "not applicable" would be disregarded from the Brazilian version of the protocol; no question had to be removed from the instrument. The Brazilian Portuguese version was entitled "Índice de Fadiga Vocal - IFV" and features 19 questions, equivalent to the original instrument. Of the 19 items, 11 were related with tiredness of voice and voice avoidance, five concerned physical discomfort associated with voicing, and three were related to improvement of symptoms with rest or lack thereof. The Brazilian version of the VFI presents cultural and linguistic equivalence to the original instrument. The IFV validation into Brazilian Portuguese is in progress.

  6. Reliability and validity of the Incontinence Quiz-Turkish version.

    Science.gov (United States)

    Kara, Kerime C; Çıtak Karakaya, İlkim; Tunalı, Nur; Karakaya, Mehmet G

    2018-01-01

    The aim of this study was to investigate the reliability and validity of the Turkish version of the Incontinence Quiz, which was developed by Branch et al. (1994), to assess women's knowledge of and attitudes toward urinary incontinence. Comprehensibility of the Turkish version of the 14-item Incontinence Quiz, which was prepared following translation-back translation procedures, was tested on a pilot group of eight women, and its internal reliability, test-retest reliability and construct validity were assessed in 150 women who attended the gynecology clinics of three hospitals in İçel, Turkey. Physical and sociodemographic characteristics and presence of incontinence complaints were also recorded. Data were analyzed at the 0.05 alpha level, using SPSS version 22. The scale had good reliability and validity. The internal reliability coefficient (Cronbach α) was 0.80, test-retest correlation coefficients were 0.83-0.94; and with regard to construct validity, Kaiser-Meyer-Olkin coefficient was 0.76 and Barlett sphericity test was 562.777 (P = 0.000). Turkish version of the Incontinence Quiz had a four-factor structure, with Eigenvalues ranging from 1.17 to 4.08. The Incontinence Quiz-Turkish version is a highly comprehensible, reliable and valid scale, which may be used to assess Turkish-speaking women's knowledge of and attitudes toward urinary incontinence. © 2017 Japan Society of Obstetrics and Gynecology.

  7. Prediction of Success in External Cephalic Version under Tocolysis: Still a Challenge.

    Science.gov (United States)

    Vaz de Macedo, Carolina; Clode, Nuno; Mendes da Graça, Luís

    2015-01-01

    External cephalic version is a procedure of fetal rotation to a cephalic presentation through manoeuvres applied to the maternal abdomen. There are several prognostic factors described in literature for external cephalic version success and prediction scores have been proposed, but their true implication in clinical practice is controversial. We aim to identify possible factors that could contribute to the success of an external cephalic version attempt in our population. We retrospectively examined 207 consecutive external cephalic version attempts under tocolysis conducted between January 1997 and July 2012. We consulted the department's database for the following variables: race, age, parity, maternal body mass index, gestational age, estimated fetal weight, breech category, placental location and amniotic fluid index. We performed descriptive and analytical statistics for each variable and binary logistic regression. External cephalic version was successful in 46.9% of cases (97/207). None of the included variables was associated with the outcome of external cephalic version attempts after adjustment for confounding factors. We present a success rate similar to what has been previously described in literature. However, in contrast to previous authors, we could not associate any of the analysed variables with success of the external cephalic version attempt. We believe this discrepancy is partly related to the type of statistical analysis performed. Even though there are numerous prognostic factors identified for the success in external cephalic version, care must be taken when counselling and selecting patients for this procedure. The data obtained suggests that external cephalic version should continue being offered to all eligible patients regardless of prognostic factors for success.

  8. National Radiobiology Archives Distributed Access User`s Manual, Version 1.1. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.K.; Prather, J.C.; Ligotke, E.K.; Watson, C.R.

    1992-06-01

    This supplement to the NRA Distributed Access User`s manual (PNL-7877), November 1991, describes installation and use of Version 1.1 of the software package; this is not a replacement of the previous manual. Version 1.1 of the NRA Distributed Access Package is a maintenance release. It eliminates several bugs, and includes a few new features which are described in this manual. Although the appearance of some menu screens has changed, we are confident that the Version 1.0 User`s Manual will provide an adequate introduction to the system. Users who are unfamiliar with Version 1.0 may wish to experiment with that version before moving on to Version 1.1.

  9. United States Climate Reference Network (USCRN) Processed Data (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note, this dataset has been superseded by a newer version (see below). Users should not use this version except in rare cases (e.g., when reproducing previous...

  10. ESMO-Magnitude of Clinical Benefit Scale version 1.1

    NARCIS (Netherlands)

    Cherny, N. I.; Dafni, U.; Bogaerts, J.; Latino, N. J.; Pentheroudakis, G.; Douillard, J. -Y.; Tabernero, J.; Zielinski, C.; Piccart, M. J.; de Vries, E. G. E.

    2017-01-01

    Background: The ESMO Magnitude of Clinical Benefit Scale (ESMO-MCBS) version 1.0 (v1.0) was published in May 2015 and was the first version of a validated and reproducible tool to assess the magnitude of clinical benefit from new cancer therapies. The ESMO-MCBS was designed to be a dynamic tool with

  11. Vietnamese validation of the short version of Internet Addiction Test

    Directory of Open Access Journals (Sweden)

    Bach Xuan Tran

    2017-12-01

    Full Text Available Background and aims: The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. Methods: The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analysis was used to identify the associated factors. Results: The two-factor model of Vietnamese version of s-IAT demonstrated good psychometric properties. The internal consistency of Factor 1 (loss of control/time management was high (Cronbach's alpha=0.82 and Factor 2 (craving/social problems was satisfactory (Cronbach's alpha=0.75. Findings indicated that 20.9% youths were addicted to the Internet. Regression analysis revealed significant associations between Internet addiction and having problems in self-care, lower quality of life and high perceived stress scores. Discussion and conclusions: The Vietnamese version of s-IAT is a valid and reliable instrument to assess IA in Vietnamese population. Due to the high prevalence of IA among Vietnamese youths, IA should be paid attention in future intervention programs. s-IAT can be a useful screening tool for IA to promptly inform and treat the IA among Vietnamese youths. Keywords: Factor analysis, Short-version, Internet Addiction Test, Psychometric properties, Vietnamese

  12. Elaboration of reduced versions of Measurement tools: A practical Perspective

    Directory of Open Access Journals (Sweden)

    Nekane Balluerka

    2012-01-01

    Full Text Available The aim of the present study is to show, from a practical perspective, the guidelines that may be followed to create a reduced version of a measurement tool. Therefore, it describes in detail the process of creating the reduced Basque version of the CDS scale (Children's Depression Scale; Lang and Tisher, 1978, which measures depression in children and adolescents. In a first study, the items that make up the reduced version of the CDS (CDS-R are selected from a set of analysis conducted on a sample of 886 children and adolescents who were administered the extensive version of the CDS adapted to the Basque language (Balluerka, Gorostiaga, and Haranburu, 2012. Subsequently, the CDS-R is validated on a sample of 2,165 participants. This second study examines the factorial structure, the internal consistency and the temporal stability of the instrument, as well as the relationship between its dimensions and gender, academic performance, emotional intelligence and attachment. Thus, evidence is obtained on the reliability and validity of the reduced version of the instrument, which guarantees suitable evaluation of the construct the instrument is intended to measure.

  13. Reliability of short form-36 in an Internet- and a pen-and-paper version

    DEFF Research Database (Denmark)

    Basnov, Maja; Kongsved, Sissel Marie; Bech, Per

    2009-01-01

    Use of Internet versions of questionnaires may have several advantages in clinical and epidemiological research, but we know little about if Internet versions differ with respect to validity and reliability. We aimed to compare Internet- and pen-and-paper versions of short form-36 (SF-36......) with respect to test-retest reliability and internal consistency. Women referred to mammography (n = 782) were randomised to receive either a paper version with a prepaid return envelope or a guideline on how to fill in the Internet version. A subgroup was asked to answer the questionnaire once again...... in the alternative version. Test-retest reliability was assessed by the intra-class correlation coefficient. Internal consistency was calculated as Cronbach's alpha. The between-version test-retest reliability for the eight subscales were between 0.63 and 0.92. Cronbach's alpha for the two versions were all between...

  14. A Spanish Version of the Expectations about Counseling Questionnaire: Translation and Validation.

    Science.gov (United States)

    Buhrke, Robin A.; Jorge, Michael

    1992-01-01

    Summarizes two studies conducted for the development and validation of a Spanish version of the Expectations about Counseling (EAC) questionnaire. Administered English and Spanish versions to bilingual university students and bilingual nonstudents. Results suggest that the Spanish version of the EAC is a reliable and valid translation for students…

  15. BehavePlus fire modeling system, version 5.0: Variables

    Science.gov (United States)

    Patricia L. Andrews

    2009-01-01

    This publication has been revised to reflect updates to version 4.0 of the BehavePlus software. It was originally published as the BehavePlus fire modeling system, version 4.0: Variables in July, 2008.The BehavePlus fire modeling system is a computer program based on mathematical models that describe wildland fire behavior and effects and the...

  16. Women's experiences of participating in the early external cephalic version 2 trial.

    Science.gov (United States)

    Murray-Davis, Beth; Marion, Anya; Malott, Anne; Reitsma, Angela; Hutton, Eileen K

    2012-03-01

    The international, multicenter External Cephalic Version 2 (ECV2) Trial compared early external cephalic version at 34(0/7) to 35(6/7) weeks with that at greater than 37 weeks. A total of 1,543 women were randomized from 68 centers in 21 countries. The goal of this component of the trial was to understand women's views about participation in a research trial and timing of external cephalic version. A postpartum questionnaire was completed containing a 5-point Likert scale examining contact and availability of staff, choice of timing of external cephalic version, preference of randomization, convenience of participating, and overall satisfaction. Participants also completed two open-ended questions related to timing of external cephalic version and satisfaction with the trial. Descriptive statistics and content analysis were used to analyze data. A total of 1,458 women completed the questionnaire, of whom 86 percent said "yes"-they would participate in the trial again. Themes influencing decisions about participating were perceptions of the external cephalic version experience, preferred mode of delivery, preferred timing of external cephalic version, and perceptions of the effectiveness of external cephalic version and of the trial environment. Many participants preferred the early timing of the procedure offered through the trial because of perceived advantages of a smaller baby being easier to turn and the opportunity for repeat procedures. Women were positive about their participation in the trial. Early external cephalic version was preferred over the traditional timing as it was perceived to afford both physiologic and practical advantages. © 2012, Copyright the Authors. Journal compilation © 2012, Wiley Periodicals, Inc.

  17. Measurement properties of translated versions of neck-specific questionnaires: a systematic review.

    Science.gov (United States)

    Schellingerhout, Jasper M; Heymans, Martijn W; Verhagen, Arianne P; de Vet, Henrica C; Koes, Bart W; Terwee, Caroline B

    2011-06-06

    Several disease-specific questionnaires to measure pain and disability in patients with neck pain have been translated. However, a simple translation of the original version doesn't guarantee similar measurement properties. The objective of this study is to critically appraise the quality of the translation process, cross-cultural validation and the measurement properties of translated versions of neck-specific questionnaires. Bibliographic databases were searched for articles concerning the translation or evaluation of the measurement properties of a translated version of a neck-specific questionnaire. The methodological quality of the selected studies and the results of the measurement properties were critically appraised and rated using the COSMIN checklist and criteria for measurement properties. The search strategy resulted in a total of 3641 unique hits, of which 27 articles, evaluating 6 different questionnaires in 15 different languages, were included in this study. Generally the methodological quality of the translation process is poor and none of the included studies performed a cross-cultural adaptation. A substantial amount of information regarding the measurement properties of translated versions of the different neck-specific questionnaires is lacking. Moreover, the evidence for the quality of measurement properties of the translated versions is mostly limited or assessed in studies of poor methodological quality. Until results from high quality studies are available, we advise to use the Catalan, Dutch, English, Iranian, Korean, Spanish and Turkish version of the NDI, the Chinese version of the NPQ, and the Finnish, German and Italian version of the NPDS. The Greek NDI needs cross-cultural validation and there is no methodologically sound information for the Swedish NDI. For all other languages we advise to translate the original version of the NDI.

  18. Timing of delivery after external cephalic version and the risk for cesarean delivery.

    Science.gov (United States)

    Kabiri, Doron; Elram, Tamar; Aboo-Dia, Mushira; Elami-Suzin, Matan; Elchalal, Uriel; Ezra, Yossef

    2011-08-01

    To estimate the association between time of delivery after external cephalic version at term and the risk for cesarean delivery. This retrospective cohort study included all successful external cephalic versions performed in a tertiary center between January 1997 and January 2010. Stepwise logistic regression was used to calculate the odds ratio (OR) for cesarean delivery. We included 483 external cephalic versions in this study, representing 53.1% of all external cephalic version attempts. The incidence of cesarean delivery for 139 women (29%) who gave birth less than 96 hours from external cephalic version was 16.5%; for 344 women (71%) who gave birth greater than 96 hours from external cephalic version, the incidence of cesarean delivery was 7.8% (P = .004). The adjusted OR for cesarean delivery was 2.541 (95% confidence interval 1.36-4.72). When stratified by parity, the risk for cesarean delivery when delivery occurred less than 96 hours after external cephalic version was 2.97 and 2.28 for nulliparous and multiparous women, respectively. Delivery at less than 96 hours after successful external cephalic version was associated with an increased risk for cesarean delivery. III.

  19. The Effects of FreeSurfer Version, Workstation Type, and Macintosh Operating System Version on Anatomical Volume and Cortical Thickness Measurements

    OpenAIRE

    Gronenschild, Ed H. B. M.; Habets, Petra; Jacobs, Heidi I. L.; Mengelers, Ron; Rozendaal, Nico; van Os, Jim; Marcelis, Machteld

    2012-01-01

    FreeSurfer is a popular software package to measure cortical thickness and volume of neuroanatomical structures. However, little if any is known about measurement reliability across various data processing conditions. Using a set of 30 anatomical T1-weighted 3T MRI scans, we investigated the effects of data processing variables such as FreeSurfer version (v4.3.1, v4.5.0, and v5.0.0), workstation (Macintosh and Hewlett-Packard), and Macintosh operating system version (OSX 10.5 and OSX 10.6). S...

  20. GEMPAK 5.1 - A GENERAL METEOROLOGICAL PACKAGE (UNIX VERSION)

    Science.gov (United States)

    Desjardins, M. L.

    1994-01-01

    GEMPAK is a general meteorological software package developed at NASA/Goddard Space Flight Center. It includes programs to analyze and display surface, upper-air, and gridded data, including model output. There are very general programs to list, edit, and plot data on maps, to display profiles and time series, to draw and fill contours, to draw streamlines, to plot symbols for clouds, sky cover, and pressure tendency, and draw cross sections in the case of gridded data and sounding data. In addition, there are Barnes objective analysis programs to grid surface and upper-air data. The programs include the capabilities to derive meteorological parameters from those found in the dataset, to perform vertical interpolations of sounding data to different coordinate systems, and to compute an extensive set of gridded diagnostic quantities by specifying various nested combinations of scalars and vector arithmetic, algebraic, and differential operators. The GEMPAK 5.1 graphics/transformation subsystem, GEMPLT, provides device-independent graphics. GEMPLT also has the capability to display output in a variety of map projections or overlaid on satellite imagery. GEMPAK 5.1 is written in FORTRAN 77 and C-language and has been implemented on VAX computers under VMS and on computers running the UNIX operating system. During installation and normal use, this package occupies approximately 100Mb of hard disk space. The UNIX version of GEMPAK includes drivers for several graphic output systems including MIT's X Window System (X11,R4), Sun GKS, PostScript (color and monochrome), Silicon Graphics, and others. The VMS version of GEMPAK also includes drivers for several graphic output systems including PostScript (color and monochrome). The VMS version is delivered with the object code for the Transportable Applications Environment (TAE) program, version 4.1 which serves as a user interface. A color monitor is recommended for displaying maps on video display devices. Data for rendering

  1. Tinnitus functional index: validation of the German version for Switzerland.

    Science.gov (United States)

    Peter, Nicole; Kleinjung, Tobias; Jeker, Raphael; Meyer, Martin; Klaghofer, Richard; Weidt, Steffi

    2017-05-05

    Different standardized questionnaires are used to assess tinnitus severity, making comparisons across studies difficult. These questionnaires are also used to measure treatment-related changes in tinnitus although they were not designed for this purpose. To solve these problems, a new questionnaire - the Tinnitus Functional Index (TFI) - has been established. The TFI is highly responsive to treatment-related change and promises to be the new gold standard in tinnitus evaluation. The aim of the current study was to validate a German version of the TFI for a German-speaking population in Switzerland. At the ENT department of the University Hospital Zurich, 264 subjects completed an online survey including the German version for Switzerland of TFI, Tinnitus Handicap Inventory (THI), Beck Depression Inventory (BDI), Beck Anxiety Inventory (BAI) and sociodemographic variables. Internal consistency of the TFI was calculated with Cronbach's alpha coefficient. Pearson correlation coefficients were used for the test-retest reliability of the TFI and to investigate convergent and discriminant validity between the THI and the BDI and BAI, respectively. Factor analysis was assessed using a principal component analysis with oblique rotation. The different factors extracted were then compared with the original questionnaire. The German version of the TFI for Switzerland showed an excellent internal consistency (Cronbach's alpha of 0.97) and an excellent test-retest reliability of 0.91. The convergent validity with THI was high (r = 0.86). The discriminant validity with BAI and BDI showed moderate results (BAI: r = 0.60 and BDI: r = 0.65). In the factor analysis only five factors with one main factor could be extracted instead of eight factors as described in the original version. Nevertheless, relations to the original eight subscales could be demonstrated. The German version of the TFI for Switzerland is a suitable instrument for measuring the impact of tinnitus

  2. Embrittlement data base, version 1

    International Nuclear Information System (INIS)

    Wang, J.A.

    1997-08-01

    The aging and degradation of light-water-reactor (LWR) pressure vessels is of particular concern because of their relevance to plant integrity and the magnitude of the expected irradiation embrittlement. The radiation embrittlement of reactor pressure vessel (RPV) materials depends on many different factors such as flux, fluence, fluence spectrum, irradiation temperature, and preirradiation material history and chemical compositions. These factors must be considered to reliably predict pressure vessel embrittlement and to ensure the safe operation of the reactor. Based on embrittlement predictions, decisions must be made concerning operating parameters and issues such as low-leakage-fuel management, possible life extension, and the need for annealing the pressure vessel. Large amounts of data from surveillance capsules and test reactor experiments, comprising many different materials and different irradiation conditions, are needed to develop generally applicable damage prediction models that can be used for industry standards and regulatory guides. Version 1 of the Embrittlement Data Base (EDB) is such a comprehensive collection of data resulting from merging version 2 of the Power Reactor Embrittlement Data Base (PR-EDB). Fracture toughness data were also integrated into Version 1 of the EDB. For power reactor data, the current EDB lists the 1,029 Charpy transition-temperature shift data points, which include 321 from plates, 125 from forgoings, 115 from correlation monitor materials, 246 from welds, and 222 from heat-affected-zone (HAZ) materials that were irradiated in 271 capsules from 101 commercial power reactors. For test reactor data, information is available for 1,308 different irradiated sets (352 from plates, 186 from forgoings, 303 from correlation monitor materials, 396 from welds and 71 from HAZs) and 268 different irradiated plus annealed data sets

  3. The propagation effect of paper version and the iPad version for periodicals

    Directory of Open Access Journals (Sweden)

    Cong Zhang

    2015-04-01

    Full Text Available Purpose: Digital journal created a new development pattern. We use journal APP as an example to analyze how to migrate the journal content to Internet and other kind of media. Based on the case study of GQ and other fashion magazines, through text analysis, control experiments, in-depth interviews and other research methods, the authors analyzed the differences and connections between the iPad App and print edition of magazines, discussed the approaches towards operation of new media, offered the tendency of mobile device platform development for China’s periodical publications. Design/methodology/approach: control experiment. Findings: The authors give a stance that the print edition of periodical publication will being alive still, and conclude that journal APP and printed version can be mutually beneficial and achieve a win-win state. And we believe that the journal APP is good at advertising propagation, which will accelerate the development of journal APP in such the information age, and such kind of media can integrate many information with variety of media forms. Research limitations/implications: Because of the limitation of technology, the authors only have the experiment on fashion magazine, which might to some degree simplify the issue under discussion. Practical implications: According to the conclusion of a series of experiments, we can imply the future of the media, and give the suggestion of both paper version and ipad version of the journal. Social implications: Since people can not live without media and media has to develope with the help of public, we have to give the new way of both sunrise media and sunset media. Originality/value: Based on the case study of GQ and other fashion magazines, through text analysis, control experiments, in-depth interviews and other research methods, the authors analyzed the differences and connections between the iPad App and print edition of magazines, discussed the approaches towards

  4. Interventions to help external cephalic version for breech presentation at term.

    Science.gov (United States)

    Hofmeyr, G J

    2004-01-01

    Breech presentation places a fetus at increased risk. The outcome for the baby is improved by planned caesarean section compared with planned vaginal delivery. External cephalic version attempts to reduce the chances of breech presentation at birth, but is not always successful. Tocolytic drugs to relax the uterus as well as other methods have been used in an attempt to facilitate external cephalic version at term. To assess the effects of routine tocolysis, fetal acoustic stimulation, epidural or spinal analgesia and transabdominal amnioinfusion for external cephalic version at term on successful version and measures of pregnancy outcome. The Cochrane Pregnancy and Childbirth Group trials register (September 2003) and the Cochrane Central Register of Controlled Trials (The Cochrane Library, Issue 3, 2003) were searched. Randomised and quasi-randomised trials comparing routine versus selective or no tocolysis; fetal acoustic stimulation in midline fetal spine positions versus dummy or no stimulation; epidural or spinal analgesia versus no regional analgesia; or transabdominal amnioinfusion versus no amnioinfusion for external cephalic version at term. The reviewer assessed eligibility and trial quality. In six trials, routine tocolysis with beta-stimulants was associated with fewer failures of external cephalic version (relative risk (RR) 0.74, 95% confidence interval (CI) 0.64 to 0.87). The reduction in non-cephalic presentations at birth was not statistically significant. Caesarean sections were reduced (RR 0.85, 95% CI 0.72 to 0.99). In four small trials, sublingual nitroglycerine used as a tocolytic was associated with significant side-effects, and was not found to be effective. Fetal acoustic stimulation in midline fetal spine positions was associated with fewer failures of external cephalic version at term (RR 0.17, 95% CI 0.05 to 0.60). With epidural or spinal analgesia, external cephalic version failure, non-cephalic births and caesarean sections were

  5. COSY INFINITY version 8

    International Nuclear Information System (INIS)

    Makino, Kyoko; Berz, Martin

    1999-01-01

    The latest version of the particle optics code COSY INFINITY is presented. Using Differential Algebraic (DA) methods, the code allows the computation of aberrations of arbitrary field arrangements to in principle unlimited order. Besides providing a general overview of the code, several recent techniques developed for specific applications are highlighted. These include new features for the direct utilization of detailed measured fields as well as rigorous treatment of remainder bounds

  6. Integrated Procurement Management System, Version II

    Science.gov (United States)

    Collier, L. J.

    1985-01-01

    Integrated Procurement Management System, Version II (IPMS II) is online/ batch system for collecting developing, managing and disseminating procurementrelated data at NASA Johnson Space Center. Portions of IPMS II adaptable to other procurement situations.

  7. Prevalence, outcome, and women's experiences of external cephalic version in a low-risk population.

    Science.gov (United States)

    Rijnders, Marlies; Offerhaus, Pien; van Dommelen, Paula; Wiegers, Therese; Buitendijk, Simone

    2010-06-01

    Until recently, external cephalic version to prevent breech presentation at birth was not widely accepted. The objective of our study was to assess the prevalence, outcomes, and women's experiences of external cephalic version to improve the implementation of the procedure in the Netherlands. A prospective cohort study was conducted of 167 women under the care of a midwife with confirmed breech presentation at a gestational age of 33 completed weeks or more. Between June 2007 and January 2008, 167 women with a confirmed breech presentation were offered an external cephalic version. Of this group, 123 women (73.7%, 95% CI: 65.5-80.5) subsequently received the version. These women had about a ninefold increased probability of a cephalic presentation at birth compared with women who did not undergo a version (relative risk [RR]: 8.8, 95% CI: 2.2-34.8). The chance of a vaginal birth after an external cephalic version was almost threefold (RR: 2.7, 95% CI: 1.5-5.0). The success rate was 39 percent, although considerable differences existed associated with region and parity. Ninety-four percent of women with a successful version rated it as a good experience compared with 71 percent of women who had a failed version (p = 0.015). Significant pain during the version was experienced by 34 percent of women, of whom 18 percent also experienced fear during the version, compared with no women who reported little or no pain (p = 0.006). Women who reported significant pain or fear during the version experienced the version more negatively (OR: 6.0, 95% CI: 3.3-12.2 and OR: 2.7, 95% CI: 1.1-6.0, respectively). One in every four women with a breech presentation in independent midwifery care did not receive an external cephalic version. Of the women who received a version one third experienced significant pain during the procedure. Considerable regional variation in success rate existed.

  8. Measurement properties of translated versions of neck-specific questionnaires: a systematic review

    Directory of Open Access Journals (Sweden)

    de Vet Henrica C

    2011-06-01

    Full Text Available Abstract Background Several disease-specific questionnaires to measure pain and disability in patients with neck pain have been translated. However, a simple translation of the original version doesn't guarantee similar measurement properties. The objective of this study is to critically appraise the quality of the translation process, cross-cultural validation and the measurement properties of translated versions of neck-specific questionnaires. Methods Bibliographic databases were searched for articles concerning the translation or evaluation of the measurement properties of a translated version of a neck-specific questionnaire. The methodological quality of the selected studies and the results of the measurement properties were critically appraised and rated using the COSMIN checklist and criteria for measurement properties. Results The search strategy resulted in a total of 3641 unique hits, of which 27 articles, evaluating 6 different questionnaires in 15 different languages, were included in this study. Generally the methodological quality of the translation process is poor and none of the included studies performed a cross-cultural adaptation. A substantial amount of information regarding the measurement properties of translated versions of the different neck-specific questionnaires is lacking. Moreover, the evidence for the quality of measurement properties of the translated versions is mostly limited or assessed in studies of poor methodological quality. Conclusions Until results from high quality studies are available, we advise to use the Catalan, Dutch, English, Iranian, Korean, Spanish and Turkish version of the NDI, the Chinese version of the NPQ, and the Finnish, German and Italian version of the NPDS. The Greek NDI needs cross-cultural validation and there is no methodologically sound information for the Swedish NDI. For all other languages we advise to translate the original version of the NDI.

  9. Measurement properties of translated versions of neck-specific questionnaires: a systematic review

    Science.gov (United States)

    2011-01-01

    Background Several disease-specific questionnaires to measure pain and disability in patients with neck pain have been translated. However, a simple translation of the original version doesn't guarantee similar measurement properties. The objective of this study is to critically appraise the quality of the translation process, cross-cultural validation and the measurement properties of translated versions of neck-specific questionnaires. Methods Bibliographic databases were searched for articles concerning the translation or evaluation of the measurement properties of a translated version of a neck-specific questionnaire. The methodological quality of the selected studies and the results of the measurement properties were critically appraised and rated using the COSMIN checklist and criteria for measurement properties. Results The search strategy resulted in a total of 3641 unique hits, of which 27 articles, evaluating 6 different questionnaires in 15 different languages, were included in this study. Generally the methodological quality of the translation process is poor and none of the included studies performed a cross-cultural adaptation. A substantial amount of information regarding the measurement properties of translated versions of the different neck-specific questionnaires is lacking. Moreover, the evidence for the quality of measurement properties of the translated versions is mostly limited or assessed in studies of poor methodological quality. Conclusions Until results from high quality studies are available, we advise to use the Catalan, Dutch, English, Iranian, Korean, Spanish and Turkish version of the NDI, the Chinese version of the NPQ, and the Finnish, German and Italian version of the NPDS. The Greek NDI needs cross-cultural validation and there is no methodologically sound information for the Swedish NDI. For all other languages we advise to translate the original version of the NDI. PMID:21645355

  10. A space-time lattice version of scalar electrodynamics

    International Nuclear Information System (INIS)

    Kijowski, J.; Thielmann, A.

    1993-10-01

    A Minkowski-lattice version of quantum scalar electrodynamics is constructed. Quantum field is consequently described in a gauge-independent way, i.e. the algebra of quantum observables of the theory is generated by gauge-invariant operators assigned to zero-, one-, and two-dimensional elements of the lattice. The operators satisfy canonical commutation relations. Field dynamics is formulated in terms of difference equations imposed on the field operators. The dynamics is obtained from a discrete version of the path-integral. (author). 19 refs

  11. Development of IMPACTS-BRC, Version 2.1

    International Nuclear Information System (INIS)

    Rao, R.R.; Kozak, M.W.; Rollstin, J.A.

    1991-01-01

    IMPACTS-BRC is a computer program developed to conduct scoping analyses for use in supporting rulemaking on petitions for exemption of waste streams from multiple producers. It was not initially intended for use on individual license applications for specific sites. However, the Federal Register, Volume 51, Number 168, specifies that IMPACTS-BRC be used to evaluate incoming license applications. This creates a problem since IMPACTS-BRC is not being used for its intended purpose. It is a generic code that is now being used for site specific applications. This is only a valid procedure if it can be shown that generic results from IMPACTS-BRC are conservative when compared to results from site specific models. Otherwise, IMPACTS-BRC should not be used. The purpose of this work was to verify that IMPACTS-BRC works as specified in its user's guide. In other words, Sandia National Laboratories (SNL) has determined that the mathematical models given in the user's guide are correctly implemented into the computer code. No direct work has been done to verify that the mathematical models used in the code are appropriate for the purpose that they are being used. In fact, scrutiny of the groundwater transport models in IMPACTS-BRC has led us to recommend that alternate geosphere models should be used. Other work carried out for this project included verifying that the input data for IMPACTS-BRC is correct and traceable. This was carried out, and a new version of the data with these qualities was produced. The new version of the data was used with the verified IMPACTS-BRC, Version 2.0 to produce IMPACTS-BRC, Version 2.1

  12. French version of the Functional Assessment of Cancer Therapy-Cognitive Function (FACT-Cog) version 3.

    Science.gov (United States)

    Joly, F; Lange, M; Rigal, O; Correia, H; Giffard, B; Beaumont, J L; Clisant, S; Wagner, L

    2012-12-01

    Impairment of cognitive function, a common complaint in patients receiving chemotherapy, is usually measured through neuropsychological tests. Patient self-evaluation of cognitive difficulties is an important complement to those tests. The Functional Assessment of Cancer Therapy-Cognitive Function (FACT-Cog) is a self-report questionnaire with potential to be used in standard clinical practice as a tool for evaluating patient's cognitive function before, during, and after chemotherapy. The purpose of our study was to conduct linguistic validation of the French version of the FACT-Cog. Both qualitative and quantitative methods were used in this study. After undergoing a rigorous translation methodology, the French FACT-Cog version was pretested in France with 35 cancer patients undergoing chemotherapy treatment. Interviews were conducted with all patients to ascertain their understanding of each item. The validation of the final version was conducted among 63 cancer patients, and sociodemographic information was collected as well as brief measure of cognitive function and depression score. Patient comments obtained through the cognitive debriefing interviews indicated that patients understand the French FACT-Cog items as they are intended and that the measure is culturally appropriate. Internal consistency reliability of the subscales, evaluated using Cronbach's coefficient alpha, was high for all four subscales: Perceived Cognitive Impairments = 0.93, Impact On QOL = 0.85, Comments From Others = 0.70, and Perceived Cognitive Abilities = 0.89. All item-total correlations for each subscale were greater than 0.20, and most were greater than 0.50. Results from this study effectively demonstrate that the French FACT-Cog is a reliable instrument for the self-reporting of cognitive abilities in patients undergoing chemotherapy.

  13. Factor Structure of the Chinese Version of the Parent Adult-Child Relationship Questionnaire

    Directory of Open Access Journals (Sweden)

    Daoyang Wang

    2018-03-01

    Full Text Available The Parent Adult-Child Relationship Questionnaire (PACQ included two identical versions of the 13-item scale, which were administered to each subject, one which referred to “relationship with mother” and the other to “relationship with father.” The PACQ, originally in English, is a self-report measure of the filial relationship. The present study aimed to develop a Chinese version of the PACQ and use it to explore Chinese parent adult-child relationships. A total of 454 Chinese adult-children completed the Chinese version of the PACQ. The structure of the questionnaire was analyzed using exploratory factor analysis (EFA and confirmatory factor analysis (CFA. We found that the Cronbach's α was 0.66–0.88 for fathers and 0.76–0.91 for mothers, which demonstrates high internal consistency reliabilities of the Chinese version of the PACQ. The Chinese version of the PACQ for father had similar constructs similar to with those of the original English version. However, a new factor for mothers, “attachment,” was derived from the original English version. The results suggested that the Chinese version of PACQ is a valid and reliable measure of relationship quality between Chinese adult-children and their parents.

  14. Patient satisfaction with childbirth after external cephalic version.

    Science.gov (United States)

    Bogner, Gerhard; Hammer, Barbara Eva; Schausberger, Christiane; Fischer, Thorsten; Reisenberger, Klaus; Jacobs, Volker

    2014-03-01

    To assess acceptance and impact of external cephalic version (ECV) for breech presentation at term on maternal satisfaction with childbirth. Retrospective study on n = 131 women with breech presentation comparing maternal satisfaction after ECV and consecutive childbirth (n = 66; 50.4% of these successful attempts in n = 33; 50%) against the group without ECV and primary caesarean section (CS) (n = 65; 49.6%) instead using a questionnaire. Women with successful ECV tolerated side effects of the intervention better than after unsuccessful ECV (pain, tocolytics, mental and physical state, for all p version were more satisfied with childbirth than women with planned CS (p = 0.05). Women with version attempts tend to perceive childbirth as being less problematic with fewer complications (9.5 vs. 19%, p = 0.12). Unsuccessful ECVs had no negative impact on satisfaction with childbirth (p = 0.072). Attempting ECV seems to be an option for increasing the rate of vaginal births with breech presentation without negative impact on maternal satisfaction regarding consecutive childbirth.

  15. Antepartum transabdominal amnioinfusion to facilitate external cephalic version after initial failure.

    Science.gov (United States)

    Benifla, J L; Goffinet, F; Darai, E; Madelenat, P

    1994-12-01

    Transabdominal amnioinfusion can be used to facilitate external cephalic version. Our technique involves filling the uterine cavity with 700 or 900 mL of 37C saline under continuous echographic monitoring. External cephalic version is done the next morning. We have used this procedure in six women, all of whom had previous unsuccessful attempts at external cephalic version. After amnioinfusion, all six patients were converted to cephalic presentation and delivered normally, without obstetric or neonatal complications.

  16. A Slovenian version of the "clinical learning environment, supervision and nurse teacher scale (Cles+T)" and its comparison with the Croatian version.

    Science.gov (United States)

    Žvanut, Boštjan; Lovrić, Robert; Kolnik, Tamara Štemberger; Šavle, Majda; Pucer, Patrik

    2018-02-26

    Nursing clinical learning environments are particularly important for the achievement of good practice in clinical training of student nurses, and thus, for the nursing competence development. Hence, it is important to have an instrument consisting of reliable and valid criteria for assessing the clinical learning environment, applicable in different contexts, and translated in the respondents mother tongue. The goal of the present research was to test the reliability and validity of the Slovenian version of the "Clinical Learning Environment, Supervision and Nurse Teacher evaluation scale", and to compare it with the Croatian version. The data was collected between 10 March and 10 June 2015 at four Slovenian institutions, where nursing BSc study programmes are performed. The final sample consisted of 232 students (response rate 68.8%): 81.9% were females and 18.1% males, average age was 23. The translated instrument in Slovenian language resulted as reliable and valid, it reflects the expected five factors of the original version despite some minor problems in the factor structure and in test-retest. The most important difference between the Slovenian and Croatian version is in the factor structure regarding the implementation of roles in clinical learning environment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. MEASUREMENT AND PRECISION, EXPERIMENTAL VERSION.

    Science.gov (United States)

    Harvard Univ., Cambridge, MA. Harvard Project Physics.

    THIS DOCUMENT IS AN EXPERIMENTAL VERSION OF A PROGRAMED TEXT ON MEASUREMENT AND PRECISION. PART I CONTAINS 24 FRAMES DEALING WITH PRECISION AND SIGNIFICANT FIGURES ENCOUNTERED IN VARIOUS MATHEMATICAL COMPUTATIONS AND MEASUREMENTS. PART II BEGINS WITH A BRIEF SECTION ON EXPERIMENTAL DATA, COVERING SUCH POINTS AS (1) ESTABLISHING THE ZERO POINT, (2)…

  18. Measuring the Declared SDK Versions and Their Consistency with API Calls in Android Apps

    OpenAIRE

    Wu, Daoyuan; Liu, Ximing; Xu, Jiayun; Lo, David; Gao, Debin

    2017-01-01

    Android has been the most popular smartphone system, with multiple platform versions (e.g., KITKAT and Lollipop) active in the market. To manage the application's compatibility with one or more platform versions, Android allows apps to declare the supported platform SDK versions in their manifest files. In this paper, we make a first effort to study this modern software mechanism. Our objective is to measure the current practice of the declared SDK versions (which we term as DSDK versions aft...

  19. Preliminary site description. Simpevarp area - version 1.1

    Energy Technology Data Exchange (ETDEWEB)

    Winberg, Anders [ed.

    2004-08-01

    Site characterisation in the Oskarshamn area is currently conducted at two adjoining localities, the Simpevarp and Laxemar subareas. This report presents the interim version (model version Simpevarp 1.1 of S1.1 for short) of the preliminary Site Descriptive Model for the Simpevarp subarea. The basis for this interim version is quality-assured, geoscientific and ecological field data from the Simpevarp subarea (and in part from the Laxemar area) available in the SKB SICADA and GIS data bases as of July 1, 2003 as well as version 0 of the Site Descriptive Model. The new data collected during the initial site investigation phase up till the date of data freeze S1.1 constitute the basis for the update of version 0 to version S1.1. These data include results from surface investigations in the subarea with its regional environment and from drillings and investigations in boreholes. The surface-based data sets were, in a relative sense, extensive compared with data sets from boreholes, were the information largely was limited to information from one c. 1,000 m deep cored borehole (KSH01A), two existing cored boreholes and three c. 200 m deep percussion-drilled boreholes. Discipline-specific models are developed for the selected regional and local model volumes and these models are subsequently integrated into a unified site description. The current methodologies for developing discipline-specific models and their integration are documented in methodology/ strategy reports. In the present work, the procedures and guidelines given in those reports were followed to the extent possible given the data and information available at the time of data freeze for model version S1.1. Compared with version 0 there are considerable additional features in the version S1.1, especially in the geological description and in the description of the near surface. The geological models of lithology and deformation zones are based on borehole information and surface data of much higher

  20. EASI graphics - Version II

    International Nuclear Information System (INIS)

    Allensworth, J.A.

    1984-04-01

    EASI (Estimate of Adversary Sequence Interruption) is an analytical technique for measuring the effectiveness of physical protection systems. EASI Graphics is a computer graphics extension of EASI which provides a capability for performing sensitivity and trade-off analyses of the parameters of a physical protection system. This document reports on the implementation of the Version II of EASI Graphics and illustrates its application with some examples. 5 references, 15 figures, 6 tables

  1. Using Bacteria to Store Renewable Energy (Text Version) | News | NREL

    Science.gov (United States)

    Using Bacteria to Store Renewable Energy (Text Version) Using Bacteria to Store Renewable Energy is a text version of the video entitled "Using Bacteria to Store Renewable Energy." ; Bacteria from some of the Earth's harshest environments now have a new home at NREL. [A natural spring has

  2. MR evaluation of femoral neck version and tibial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, James Karl; Dwek, Jerry R. [University of California, San Diego, Children' s Hospital and Health Center, Department of Radiology, San Diego, CA (United States); Pring, Maya E. [Rady Children' s Hospital, Department of Pediatric Orthopedic Surgery, San Diego, CA (United States)

    2012-01-15

    Abnormalities of femoral neck version have been associated with a number of hip abnormalities in children, including slipped capital femoral epiphysis, proximal femoral focal deficiency, coxa vara, a deep acetabulum and, rarely, developmental dysplasia of the hip. Orthopedic surgeons also are interested in quantifying the femoral neck anteversion or retroversion in children especially to plan derotational osteotomies. Historically, the angle of femoral version and tibial torsion has been measured with the use of radiography and later by CT. Both methods carry with them the risks associated with ionizing radiation. Techniques that utilize MR are used less often because of the associated lengthy imaging times. This article describes a technique using MRI to determine femoral neck version and tibial torsion with total scan times of approximately 10 min. (orig.)

  3. Comparing Danish and Swedish versions of PISA scientific literacy

    DEFF Research Database (Denmark)

    Serder, Malmø University, Margareta; Sørensen, Helene

    This paper presents a comparison between the Swedish, Danish, English, and French versions of three scientific literacy test-units from the released PISA items 2006. More specifically it compares how different words and concepts have been translated in the Swedish and Danish tests, compared...... to the English and French original versions. Differences that occur as a result of the translation process concerning words’ meaning are demonstrated. The possible consequences of such differences are exemplified by an excerpt from a situation in which Swedish 15-year-old students collaboratively worked...... with these three PISA units. In the paper we claim that in spite of detailed and strongly controlled methods for achieving translations of high standard used by the PISA, important and perhaps even decisive, differences between the four versions exist....

  4. XTALOPT version r11: An open-source evolutionary algorithm for crystal structure prediction

    Science.gov (United States)

    Avery, Patrick; Falls, Zackary; Zurek, Eva

    2018-01-01

    Version 11 of XTALOPT, an evolutionary algorithm for crystal structure prediction, has now been made available for download from the CPC library or the XTALOPT website, http://xtalopt.github.io. Whereas the previous versions of XTALOPT were published under the Gnu Public License (GPL), the current version is made available under the 3-Clause BSD License, which is an open source license that is recognized by the Open Source Initiative. Importantly, the new version can be executed via a command line interface (i.e., it does not require the use of a Graphical User Interface). Moreover, the new version is written as a stand-alone program, rather than an extension to AVOGADRO.

  5. HECTR Version 1.5 user's manual

    International Nuclear Information System (INIS)

    Dingman, S.E.; Camp, A.L.; Wong, C.C.; King, D.B.; Gasser, R.D.

    1986-04-01

    This report describes the use and features of HECTR Version 1.5. HECTR is a relatively fast-running, lumped-volume containment analysis computer program that is most useful for performing parametric studies. The main purpose of HECTR is to analyze nuclear reactor accidents involving the transport and combustion of hydrogen, but HECTR can also function as an experiment analysis tool and can solve a limited set of other types of containment problems. New models added to HECTR Version 1.5 include fan coolers, containment leakage, continuous burning, and the capability to treat carbon monoxide and carbon dioxide. Models for the ice condenser, sumps, and Mark III suppression pool were upgraded. HECTR is designed for flexibility and provides for user control of many important parameters, particularly those related to hydrogen combustion. Built-in correlations and default values of key parameters are also provided

  6. Kernel versions of some orthogonal transformations

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg

    Kernel versions of orthogonal transformations such as principal components are based on a dual formulation also termed Q-mode analysis in which the data enter into the analysis via inner products in the Gram matrix only. In the kernel version the inner products of the original data are replaced...... by inner products between nonlinear mappings into higher dimensional feature space. Via kernel substitution also known as the kernel trick these inner products between the mappings are in turn replaced by a kernel function and all quantities needed in the analysis are expressed in terms of this kernel...... function. This means that we need not know the nonlinear mappings explicitly. Kernel principal component analysis (PCA) and kernel minimum noise fraction (MNF) analyses handle nonlinearities by implicitly transforming data into high (even infinite) dimensional feature space via the kernel function...

  7. Validation of a Portuguese Version of the Children's Hope Scale

    Science.gov (United States)

    Marques, Susana C.; Pais-Ribeiro, J. L.; Lopez, Shane J.

    2009-01-01

    The article describes the development of the Portuguese version of the Children's Hope Scale and the examination of its psychometric properties. A sample of 367 Portuguese students completed the Portuguese-language versions of the Children's Hope Scale (CHS; Snyder et al., 1997), Students' Life Satisfaction Scale (SLSS; Huebner, 1991), Global…

  8. Procedure guideline for radioiodine test. Version; Verfahrensanweisung zum Radioiodtest. Version 2

    Energy Technology Data Exchange (ETDEWEB)

    Dietlein, M.; Dressler, J.; Leisner, B.; Reiners, C.; Schicha, H. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Eschner, W.; Lassmann, M. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Deutsche Gesellschaft fuer Medizinische Physik (DGMP) (Germany)

    2003-06-01

    The version 2 of the procedure guideline for radioiodine test is an update of the guideline published in 1999. The following statements were added or modified: The procedure guideline discusses the pros and cons of a single measurement or of repeated measurements of the iodine-131 uptake and their optimal timing. Different formulas are described when one, two or three values of the radioiodine kinetic are available. The probe with a sodium iodide crystal, alternative or additionally the gamma-camera using the ROI-technique are instrumentations for the measurement of iodine-131 uptake. A possible source of error is an inappropriate measurement (sonography) of the target volume. The patients' preparation includes the withdrawal of antithyroid drugs 2-3 days before radioiodine administration. The patient has to avoid iodine-containing medication and the possibility of additives of iodide in vitamin- or electrolyte-supplementation has to be considered. (orig.) [German] Mit der Version 2 der Verfahrensanweisung zum Radioiodtest wird die in 1999 publizierte Verfahrensanweisung aktualisiert. Ergaenzungen und Modifikationen betreffen die notwendige Anzahl und die Zeitintervalle der Iod-131-Uptake-Messungen. Diskutiert werden die Argumente fuer die ein- oder mehrmalige Uptake-Messung. Berechnungsformeln fuer ein, zwei und drei Messpunkte werden angegeben. Als Messgeraete koennen die Uptake-Messsonde, alternativ oder zusaetzlich die Gammakamera mit ROI-Technik zum Einsatz kommen. Fehler bei der Volumetrie (Sonographie) des Zielvolumens gehen unmittelbar in die Berechnung der Therapieaktivitaet ein. Zur Vorbereitung der Patienten wird ein Absetzen der thyreostatischen Medikation 2 bis 3 Tage vor dem Radioiodtest empfohlen. Moeglich Iod(id) zusaetze in Multivitamin- und Spurenelementkombinationen sollten bedacht werden. (orig.)

  9. Physical study of the 'snow flake' version of the reactor EL-3 (1963); Etude physique de la version ''cristal de neige'' de la pile EL-3 (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Abillon, E; Genthon, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    A systematic study has been made of the different thermodynamic and neutronic aspects of various versions of the 'snow flake' likely to fulfil the aims which were set out (improvement of the reactivity, of the experimental volume, improvement in the working conditions of EL-3). After this systematic study, a choice was made in principle of one version amongst the several available (solutions using 8 or 10 pencils-various methods of heat transfer: corrugation, cartridges which may or may not be filled with helium... etc., variable enrichments... ). The choice is that of a version which can already at the present be considered as feasible, which represents already a notable improvement of the pile and which does not imply the existence of a major problem as far as the possible change-over later to an improved version is concerned. This choice defines a fuel element and a configuration for the core. A detailed recapitulation has been made of all the research being carried out for the possible solutions in this particular case. (authors) [French] On a etudie systematiquement les differents aspects thermodynamiques et neutroniques de diverses versions 'cristal de neige' susceptibles de remplir les buts fixes (amelioration en reactivite, en volume experimental, amelioration des problemes d'exploitation de EL-3). Apres cette etude systematique, on a procede au choix de principe d'une version parmi les differentes solutions possibles (solutions a 8 ou 10 crayons - possibilite de transfert de chaleur divers: corrugations, cartouches remplies He ou non.... etc., enrichissements variables... ). Ce choix est celui d'une version qu'on peut juger viable des aujourd'hui, qui represente deja une amelioration importante de la pile et qui n'implique pas de probleme majeur quant au passage ulterieur et eventuel a une version plus amelioree. Ce choix definit un element combustible, et une configuration de coeur. On a recapitule et detaille sur ce cas particulier de pile les etudes

  10. TJ-II Library Manual (Version 2)

    International Nuclear Information System (INIS)

    Tribaldos, V.; Milligen, B. Ph. van; Lopez-Fraguas, A.

    2001-01-01

    This is a manual of use of the TJ2 Numerical Library that has been developed for making numerical computations of different TJ-II configurations. This manual is a new version of the earlier manual CIEMAT report 806. (Author)

  11. NETPATH-WIN: an interactive user version of the mass-balance model, NETPATH

    Science.gov (United States)

    El-Kadi, A. I.; Plummer, Niel; Aggarwal, P.

    2011-01-01

    NETPATH-WIN is an interactive user version of NETPATH, an inverse geochemical modeling code used to find mass-balance reaction models that are consistent with the observed chemical and isotopic composition of waters from aquatic systems. NETPATH-WIN was constructed to migrate NETPATH applications into the Microsoft WINDOWS® environment. The new version facilitates model utilization by eliminating difficulties in data preparation and results analysis of the DOS version of NETPATH, while preserving all of the capabilities of the original version. Through example applications, the note describes some of the features of NETPATH-WIN as applied to adjustment of radiocarbon data for geochemical reactions in groundwater systems.

  12. Effect of Software Version on the Accuracy of an Intraoral Scanning Device.

    Science.gov (United States)

    Haddadi, Yasser; Bahrami, Golnosh; Isidor, Flemming

    2018-04-06

    To investigate the impact of software version on the accuracy of an intraoral scanning device. A master tooth was scanned with a high-precision optical scanner and then 10 times with a CEREC Omnicam scanner with software versions 4.4.0 and 4.4.4. Discrepancies were measured using quality control software. Mean deviation for 4.4.0 was 36.2 ± 35 μm and for 4.4.4 was 20.7 ± 14.2 μm (P ≤ .001). Software version has a significant impact on the accuracy of an intraoral scanner. It is important that researchers also publish the software version of scanners when publishing their findings.

  13. Vietnamese validation of the short version of Internet Addiction Test.

    Science.gov (United States)

    Tran, Bach Xuan; Mai, Hue Thi; Nguyen, Long Hoang; Nguyen, Cuong Tat; Latkin, Carl A; Zhang, Melvyn W B; Ho, Roger C M

    2017-12-01

    The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT) and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analysis was used to identify the associated factors. The two-factor model of Vietnamese version of s-IAT demonstrated good psychometric properties. The internal consistency of Factor 1 (loss of control/time management) was high (Cronbach's alpha = 0.82) and Factor 2 (craving/social problems) was satisfactory (Cronbach's alpha = 0.75). Findings indicated that 20.9% youths were addicted to the Internet. Regression analysis revealed significant associations between Internet addiction and having problems in self-care, lower quality of life and high perceived stress scores. The Vietnamese version of s-IAT is a valid and reliable instrument to assess IA in Vietnamese population. Due to the high prevalence of IA among Vietnamese youths, IA should be paid attention in future intervention programs. s-IAT can be a useful screening tool for IA to promptly inform and treat the IA among Vietnamese youths.

  14. APS beamline standard components handbook, Version 1.3

    International Nuclear Information System (INIS)

    Hahn, U.; Shu, D.; Kuzay, T.M.

    1993-02-01

    This Handbook in its current version (1.3) contains descriptions, specifications, and preliminary engineering design drawings for many of the standard components. The design status and schedules have been provided wherever possible. In the near future, the APS plans to update engineering drawings of identified standard beamline components and complete the Handbook. The completed version of this Handbook will become available to both the CATs and potential vendors. Use of standard components should result in major cost reductions for CATs in the areas of beamline design and construction

  15. Radiooncological guidelines. Radiotherapy of breast cancer. 2005 version

    International Nuclear Information System (INIS)

    Sauer, R.

    2006-01-01

    This is an updated and revised version of the DEGRO guideline of October 1999. The DEGRO guideline was updated with the focus on specific radiooncology aspects. It is based on the interdisciplinary guideline of Deutsche Krebsgesellschaft (DKG) and the contributing medical associations. This guideline, 'Diagnostik, Therapie und Nachsorge des Mammakarzinoms der Frau', was published by Informationszentrum fuer Standards in der Onkologie (ISTO) of Deutsche Krebsgesellschaft. The June 2004 version was also published as a book by AWMF and is available on the web under the register number 032/045 (www.leitlinien.net). (orig.)

  16. The Integrated Tiger Series version 5.0

    International Nuclear Information System (INIS)

    Laub, Th.W.; Kensek, R.P.; Franke, B.C.; Lorence, L.J.; Crawford, M.J.; Quirk, Th.J.

    2005-01-01

    The Integrated Tiger Series (ITS) is a powerful and user-friendly software package permitting Monte Carlo solution of linear time-independent coupled electron/photon radiation transport problems, with or without the presence of macroscopic electric and magnetic fields of arbitrary spatial dependence. The package contains programs to perform 1-, 2-, and 3-dimensional simulations. Improvements in the ITS code package since the release of version 3.0 include improved physics, multigroup and adjoint capabilities, Computer-Aided Design geometry tracking, parallel implementations of all ITS codes, and more automated sub-zoning capabilities. These improvements and others are described as current or planned development efforts. The ITS package is currently at version 5.0. (authors)

  17. Evaluation of Aquarius Version-5 Sea Surface Salinity on various spatial and temporal scales

    Science.gov (United States)

    Lee, T.

    2017-12-01

    Sea surface salinity (SSS) products from Aquarius have had three public releases with progressive improvement in data quality: Versions 2, 3, and 4, with the last one being released in October 2015. A systematic assessment of the Version-4, Level-3 Aquarius SSS product was performed on various spatial and temporal scales by comparing it with gridded Argo products (Lee 2016, Geophys. Res. Lett.). The comparison showed that the consistency of Aquarius Version-4 SSS with gridded Argo products is comparable to that between two different gridded Argo products. However, significant seasonal biases remain in high-latitude oceans. Further improvements are being made by the Aquarius team. Aquarius Version 5.0 SSS is scheduled to be released in October 2017 as the final version of the Aquarius Project. This presentation provides a similar evaluation of Version-5 SSS as reported by Lee (2016) and contrast it with the current Version-4 SSS.

  18. A Persian version of Geriatric Oral Health Assessment Index.

    Science.gov (United States)

    Rezaei, Mohammad; Rashedi, Vahid; Khedmati Morasae, Esmaeil

    2016-09-01

    This study aimed to translate the original English version of the Geriatric Oral Health Assessment Index (GOHAI) into a Persian version and to assess the preliminary psychometric properties of the translated index among a sample of Persian elders. Twelve items included in GOHAI were first translated into Persian using a back-translation technique and then were compared with the original version. Four hundred and seventeen elderly subjects who were admitted to a day care centre answered GOHAI and an attached socio-demographic questionnaire. Internal consistency of the Persian version was measured by Cronbach's alpha. Test-retest reliability was assessed by intraclass correlation coefficient (ICC) and weighted kappa. Factor structure of GOHAI was evaluated by principal component factor analysis. Mean of GOHAI score was 45.71 (SD: 5.14; range: 27-51). The mean of GOHAI score was higher for the elders who rated their oral and general health as 'good'. The Cronbach's alpha for GOHAI score was 0.748, indicating a high degree of internal consistency and homogeneity between the GOHAI items. The test-retest correlation for the total GOHAI score using ICC was 0.763 (95% CI = 0.713-0.809). Factor analysis revealed a three-factor solution that bolstered the theoretical construction of the index. Significant differences in the GOHAI scores were found for income and current number of teeth. The Persian version of the GOHAI can be used reliably to identify oral health-related concerns of older Persian speakers, but further research is needed to confirm its cultural consonance in this population. © 2014 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  19. Rock Visualization System. Technical description (RVS version 3.8)

    International Nuclear Information System (INIS)

    Curtis, P.; Elfstroem, M.; Markstroem, I.

    2007-06-01

    The Rock Visualization System (RVS) has been developed by SKB for use in visualizing geological and engineering data in 3D. The purpose of this report is to provide a technical description of RVS aimed at potential program users and interested parties as well as fulfilling the function of a more general RVS reference that can be cited when writing other technical reports. The report describes RVS version 4.0. Updated versions of this report or addenda will be made available following further development of RVS and the release of subsequent versions of the program. The report covers the following main items: Technical description of the program with illustrations and examples. Limitations of the program and of functionality. For most RVS functions step-by-step tutorials are available describing how a particular function can be used to carry out a specific task. A complete set of updated tutorials is issued with each new version release of the RVS program. However, the tutorials do not cover all the possible uses of all the individual functions but rather give an overall view of their functionality. A detailed description of every RVS function and how it can be used is included in the RVS online Help system

  20. Rock Visualization System. Technical description (RVS version 3.8)

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, P.; Elfstroem, M.; Markstroem, I. [FB Engineering, Goeteborg (Sweden)

    2005-04-01

    The Rock Visualization System (RVS) has been developed by SKB for use in visualizing geological and engineering data in 3D. The purpose of this report is to provide a technical description of RVS aimed at potential program users and interested parties as well as fulfilling the function of a more general RVS reference that can be cited when writing other technical reports. The report describes RVS version 3.8. Updated versions of this report or addenda will be made available following further development of RVS and the release of subsequent versions of the program. The report covers the following main items: Technical description of the program with illustrations and examples. Limitations of the program and of functionality. For most RVS functions step-by-step tutorials are available describing how a particular function can be used to carryout a specific task. A complete set of updated tutorials is issued with each new version release of the RVS program. However, the tutorials do not cover all the possible uses of all the individual functions but rather give an overall view of their functionality. A detailed description of every RVS function and how it can be used is included in the RVS online Help system.

  1. Rock Visualization System. Technical description (RVS version 3.8)

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, P.; Elfstroem, M.; Markstroem, I. [Golder Associates AB (Sweden)

    2007-06-15

    The Rock Visualization System (RVS) has been developed by SKB for use in visualizing geological and engineering data in 3D. The purpose of this report is to provide a technical description of RVS aimed at potential program users and interested parties as well as fulfilling the function of a more general RVS reference that can be cited when writing other technical reports. The report describes RVS version 4.0. Updated versions of this report or addenda will be made available following further development of RVS and the release of subsequent versions of the program. The report covers the following main items: Technical description of the program with illustrations and examples. Limitations of the program and of functionality. For most RVS functions step-by-step tutorials are available describing how a particular function can be used to carry out a specific task. A complete set of updated tutorials is issued with each new version release of the RVS program. However, the tutorials do not cover all the possible uses of all the individual functions but rather give an overall view of their functionality. A detailed description of every RVS function and how it can be used is included in the RVS online Help system.

  2. The development of fears of compassion scale Japanese version

    Science.gov (United States)

    Asano, Kenichi; Tsuchiya, Masao; Ishimura, Ikuo; Lin, Shuzhen; Matsumoto, Yuki; Miyata, Haruko; Kotera, Yasuhiro; Shimizu, Eiji; Gilbert, Paul

    2017-01-01

    Objectives Cultivation of compassion is a useful way to treat mental problems, but some individuals show resistance. Fears of compassion can be an obstacle for clinicians when providing psychotherapy, and for clients when engaging in interpersonal relationships. Despite its importance, a Japanese version of fears of compassion scales (for others, from others, and for self) has not yet been developed. This study developed a Japanese version of the Fears of Compassion Scales and tested its reliability and validity. Design This study used a cross-sectional design, and a self-report procedure for collecting data. Methods A total of 485 students (121 males and 364 females) answered self-report questionnaires, including the draft Fears of Compassion Scales—Japanese version. Results There were distinctive factor structures for fear of compassion from others, and for self. The fear of compassion from others scale consisted of concern about compassion from others and avoidance of compassion from others. All scales had good internal consistency, test-retest reliability, face validity, and construct validity. Discrimination and difficulty were also calculated. Conclusions These results indicate that the Fears of Compassion Scales—Japanese version is a well-constructed and useful measure to assess fears of compassion and the existence of cultural differences in fears of compassion. PMID:29023461

  3. Rock Visualization System. Technical description (RVS version 3.8)

    International Nuclear Information System (INIS)

    Curtis, P.; Elfstroem, M.; Markstroem, I.

    2005-04-01

    The Rock Visualization System (RVS) has been developed by SKB for use in visualizing geological and engineering data in 3D. The purpose of this report is to provide a technical description of RVS aimed at potential program users and interested parties as well as fulfilling the function of a more general RVS reference that can be cited when writing other technical reports. The report describes RVS version 3.8. Updated versions of this report or addenda will be made available following further development of RVS and the release of subsequent versions of the program. The report covers the following main items: Technical description of the program with illustrations and examples. Limitations of the program and of functionality. For most RVS functions step-by-step tutorials are available describing how a particular function can be used to carryout a specific task. A complete set of updated tutorials is issued with each new version release of the RVS program. However, the tutorials do not cover all the possible uses of all the individual functions but rather give an overall view of their functionality. A detailed description of every RVS function and how it can be used is included in the RVS online Help system

  4. Preliminary site description. Simpevarp area - version 1.1

    International Nuclear Information System (INIS)

    Winberg, Anders

    2004-08-01

    Site characterisation in the Oskarshamn area is currently conducted at two adjoining localities, the Simpevarp and Laxemar subareas. This report presents the interim version (model version Simpevarp 1.1 of S1.1 for short) of the preliminary Site Descriptive Model for the Simpevarp subarea. The basis for this interim version is quality-assured, geoscientific and ecological field data from the Simpevarp subarea (and in part from the Laxemar area) available in the SKB SICADA and GIS data bases as of July 1, 2003 as well as version 0 of the Site Descriptive Model. The new data collected during the initial site investigation phase up till the date of data freeze S1.1 constitute the basis for the update of version 0 to version S1.1. These data include results from surface investigations in the subarea with its regional environment and from drillings and investigations in boreholes. The surface-based data sets were, in a relative sense, extensive compared with data sets from boreholes, were the information largely was limited to information from one c. 1,000 m deep cored borehole (KSH01A), two existing cored boreholes and three c. 200 m deep percussion-drilled boreholes. Discipline-specific models are developed for the selected regional and local model volumes and these models are subsequently integrated into a unified site description. The current methodologies for developing discipline-specific models and their integration are documented in methodology/ strategy reports. In the present work, the procedures and guidelines given in those reports were followed to the extent possible given the data and information available at the time of data freeze for model version S1.1. Compared with version 0 there are considerable additional features in the version S1.1, especially in the geological description and in the description of the near surface. The geological models of lithology and deformation zones are based on borehole information and surface data of much higher

  5. New version: GRASP2K relativistic atomic structure package

    Science.gov (United States)

    Jönsson, P.; Gaigalas, G.; Bieroń, J.; Fischer, C. Froese; Grant, I. P.

    2013-09-01

    A revised version of GRASP2K [P. Jönsson, X. He, C. Froese Fischer, I.P. Grant, Comput. Phys. Commun. 177 (2007) 597] is presented. It supports earlier non-block and block versions of codes as well as a new block version in which the njgraf library module [A. Bar-Shalom, M. Klapisch, Comput. Phys. Commun. 50 (1988) 375] has been replaced by the librang angular package developed by Gaigalas based on the theory of [G. Gaigalas, Z.B. Rudzikas, C. Froese Fischer, J. Phys. B: At. Mol. Phys. 30 (1997) 3747, G. Gaigalas, S. Fritzsche, I.P. Grant, Comput. Phys. Commun. 139 (2001) 263]. Tests have shown that errors encountered by njgraf do not occur with the new angular package. The three versions are denoted v1, v2, and v3, respectively. In addition, in v3, the coefficients of fractional parentage have been extended to j=9/2, making calculations feasible for the lanthanides and actinides. Changes in v2 include minor improvements. For example, the new version of rci2 may be used to compute quantum electrodynamic (QED) corrections only from selected orbitals. In v3, a new program, jj2lsj, reports the percentage composition of the wave function in LSJ and the program rlevels has been modified to report the configuration state function (CSF) with the largest coefficient of an LSJ expansion. The bioscl2 and bioscl3 application programs have been modified to produce a file of transition data with one record for each transition in the same format as in ATSP2K [C. Froese Fischer, G. Tachiev, G. Gaigalas, M.R. Godefroid, Comput. Phys. Commun. 176 (2007) 559], which identifies each atomic state by the total energy and a label for the CSF with the largest expansion coefficient in LSJ intermediate coupling. All versions of the codes have been adapted for 64-bit computer architecture. Program SummaryProgram title: GRASP2K, version 1_1 Catalogue identifier: ADZL_v1_1 Program summary URL: http://cpc.cs.qub.ac.uk/summaries/ADZL_v1_1.html Program obtainable from: CPC Program Library

  6. Development and validation of the interview version of the Hong Kong Chinese WHOQOL-BREF.

    Science.gov (United States)

    Leung, K F; Wong, W W; Tay, M S M; Chu, M M L; Ng, S S W

    2005-06-01

    The Hong Kong Chinese version of the WHOQOL-BREF was designed as a self-administered questionnaire and has limitations in clinical application on subjects who have limitations in reading or writing. An interview version is therefore needed to avoid sampling biases in clinical studies. Since there are significant differences in the written Chinese and spoken Cantonese, which is a dialect commonly spoken among people in Hong Kong, and adaptation process for converting the written Chinese into spoken Cantonese was necessary. The interview version was designed to allow administration in both face-to-face interview and telephone interview mode. Three members of the research team translated the formal written Chinese in the self-administered version of the WHOQOL-BREF(HK) into colloquial Cantonese separately. Brief notes extracted from the facet definitions of the WHOQOL-100 were added in brackets after some questions to further explain the intention of the questions. Two series of focus groups were conducted and subsequently the field test version was produced. 329 subjects were recruited by convenient sampling method for the field test. The interview version and the self-administered version was found equivalent. The ICC values of the domain scores ranged from 0.73 in the environment domain to 0.83 in the psychological domain. The face-to-face interview and telephone interview mode of administration were also found equivalent. The ICC for the domain scores ranged from 0.76 in the social interaction domain to 0.84 in the psychological domain. The other psychometric properties of the interview version were found comparable to the self-administered version. The self-administered and the interview version of the WHOQOL-BREF are regarded as identical in group comparison. The authors advise that it is acceptable to use different versions on different subjects in the same study, provided that the same version is applied on the same subject throughout the study.

  7. A Chinese version of the Language Screening Test (CLAST for early-stage stroke patients.

    Directory of Open Access Journals (Sweden)

    Hongyan Yang

    Full Text Available There is a severe lack of aphasia screening tools for bedside use in Chinese. A number of aphasia assessment tools have recently been developed abroad, but some of these scales were not suitable for patients with acute stroke. The Language Screening Test (which includes two parallel versions [a/b] in French has been proven to be an effective and time-saving aphasia screening scale for early-stage stroke patients. Therefore, we worked out a Chinese version of the LAST taking into consideration Chinese language and culture. Two preliminary parallel versions (a/b were tested on 154 patients with stroke at acute phase and 107 patients with stroke at non-acute phase, with the Western Aphasia Battery serving as a gold standard. The equivalence between the two parallel versions and the reliability/validity of each version were assessed. The median time to complete one preliminary Chinese version (each had some item redundancy was 98 seconds. Two final parallel versions were established after adjustment/elimination of the redundant items and were found to be equivalent (intra-class correlation coefficient: 0.991. Internal consistency is(Cronbach α for each version [a/b] was 0.956 and 0.965, respectively good. Internal validity was fine: (a no floor or ceiling effect/item redundancy; (b construct validity revealed a 1-dimension structure, just like the French version. The higher educated subjects scored higher than their lower educated counterparts (p<0.01. The external validity: at the optimum cut-off point where the score of version a/b <14 in higher educated group(<13 in lower: the specificity of each version was 0.878/0.902(1/1 in lower and sensitivity was 0.972/0.944(0.944/0.944 in lower. Inter-rater equivalence (intra-class correlation coefficient was 1. The Chinese version of the Language Screening Test was proved to be an efficient and time-saving bedside aphasia screening tool for stroke patients at acute phase and can be used by an average

  8. [Validity and reliability of the spanish EQ-5D-Y proxy version].

    Science.gov (United States)

    Gusi, N; Perez-Sousa, M A; Gozalo-Delgado, M; Olivares, P R

    2014-10-01

    A proxy version of the EQ-5D-Y, a questionnaire to evaluate the Health Related Quality of Life (HRQoL) in children and adolescents, has recently been developed. There are currently no data on the validity and reliability of this tool. The objective of this study was to analyze the validity and reliability of the EQ-5D-Y proxy version. A core set of self-report tools, including the Spanish version of the EQ-5D-Y were administered to a group of Spanish children and adolescents drawn from the general population. A similar core set of internationally standardized proxy tools, including the EQ-5D-Y proxy version were administered to their parents. Test-retest reliability was determined, and correlations with other generic measurements of HRQoL were calculated. Additionally, known group validity was examined by comparing groups with a priori expected differences in HRQoL. The agreement between the self-report and proxy version responses was also calculated. A total of 477 children and adolescents and their parents participated in the study. One week later, 158 participants completed the EQ-5D-Y/EQ-5D-Y proxy to facilitate reliability analysis. Agreement between the test-retest scores was higher than 88% for EQ-5D-Y self-report, and proxy version. Correlations with other health measurements showed similar convergent validity to that observed in the international EQ-5D-Y. Agreement between the self-report and proxy versions ranged from 72.9% to 97.1%. The results provide preliminary evidence of the reliability and validity of the EQ-5D-Y proxy version. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  9. Validation of an electronic version of the Mini Asthma Quality of Life Questionnaire.

    Science.gov (United States)

    Olajos-Clow, J; Minard, J; Szpiro, K; Juniper, E F; Turcotte, S; Jiang, X; Jenkins, B; Lougheed, M D

    2010-05-01

    The Mini Asthma Quality of Life Questionnaire (MiniAQLQ) is a validated disease-specific quality of life (QOL) paper (p) questionnaire. Electronic (e) versions enable inclusion of asthma QOL in electronic medical records and research databases. To validate an e-version of the MiniAQLQ, compare time required for completion of e- and p-versions, and determine which version participants prefer. Adults with stable asthma were randomized to complete either the e- or p-MiniAQLQ, followed by a 2-h rest period before completing the other version. Agreement between versions was measured using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Two participants with incomplete p-MiniAQLQ responses were excluded. Forty participants (85% female; age 47.7 +/- 14.9 years; asthma duration 22.6 +/- 16.1 years; FEV(1) 87.1 +/- 21.6% predicted) with both AQLQ scores limitation, emotional function and environmental stimuli domains were 0.94, 0.89, 0.90, and 0.91 respectively. A small but significant bias (Delta=0.3; P=0.004) was noted in the activity limitation domain. Completion time was significantly longer for the e-version (3.8 +/- 1.9min versus 2.7 +/- 1.1min; Ppreferred the e-MiniAQLQ; 35% had no preference. This e-version of the MiniAQLQ is valid and was preferred by most participants despite taking slightly longer to complete. Generalizabilty may be limited in younger (12-17) and older (>65) adults.

  10. Development of the web-based Spanish and Catalan versions of the Euroqol 5D-Y (EQ-5D-Y) and comparison of results with the paper version.

    Science.gov (United States)

    Robles, Noemí; Rajmil, Luis; Rodriguez-Arjona, Dolors; Azuara, Marta; Codina, Francisco; Raat, Hein; Ravens-Sieberer, Ulrike; Herdman, Michael

    2015-06-03

    The objectives of the study were to develop web-based Spanish and Catalan versions of the EQ-5D-Y, and to compare scores and psychometric properties with the paper version. Web-based and paper versions of EQ-5D-Y were included in a cross-sectional study in Palafolls (Barcelona), Spain and administered to students (n = 923) aged 8 to 18 years from 2 primary and 1 secondary school and their parents. All students completed both the web-based and paper versions during school time with an interval of at least 2 h between administrations. The order of administration was randomized. Participants completed EQ-5D-Y, a measure of mental health status (the Strengths and Difficulties Questionnaire), and sociodemographic variables using a self-administered questionnaire. Parents questionnaire included parental level of education and presence of chronic conditions in children. Missing values, and floor and ceiling effects were compared between versions. Mean score differences were computed for the visual analogue scale (VAS). Percentage of agreement, kappa index (k) and intraclass correlation coefficient (ICC) were computed to analyze the level of agreement between web-based and paper versions on EQ-5D-Y dimensions and VAS. Known groups validity was analyzed and compared between the two formats. Participation rate was 77 % (n = 715). Both formats of EQ-5D-Y showed low percentages of missing values (n = 2, and 4 to 9 for web and paper versions respectively), and a high ceiling effect by dimension (range from 79 % to 96 %). Percent agreement for EQ-5D-Y dimensions on the web and paper versions was acceptable (range 89 % to 97 %), and k ranged from 0.55 (0.48-0.61, usual activities dimension) to 0.75 (0.68-0.82, mobility dimension). Mean score difference on the VAS was 0.07, and the ICC for VAS scores on the two formats was 0.84 (0.82-0.86). Both formats showed acceptable ability to discriminate according to self-perceived health, reporting chronic conditions, and

  11. A therapist version of the Alliance Negotiation Scale.

    Science.gov (United States)

    Doran, Jennifer M; Gómez-Penedo, Juan Martín; Safran, Jeremy D; Roussos, Andrés

    2018-05-02

    The aim of the current study was to design and evaluate a therapist version of the Alliance Negotiation Scale (ANS). The ANS was created in order to operationalize the construct of dyadic negotiation in psychotherapy and to augment existing conceptualizations of the working alliance. The ANS has existed only as a client self-report form since its inception and has demonstrated promise as a psychotherapy process measure. This research intended to develop a complementary therapist self-report version of the measure. The scale creation process is discussed in detail, and the results of a preliminary psychometric investigation are reported. The ANS-Therapist version (ANS-T) was developed using a sample of therapists (n = 114) through a principal components analysis procedure. The ANS-T contains 9 unidimensional items and was moderately correlated with therapist-reported working alliance (r = .468). The results of the study support the composition of the ANS-T and provide initial support for the reliability and validity of the measure. Copyright © 2018 John Wiley & Sons, Ltd.

  12. Finite element analysis of the Girkmann problem using the modern hp-version and the classical h-version

    KAUST Repository

    Niemi, Antti; Babuška, Ivo M.; Pitkä ranta, Juhani; Demkowicz, Leszek F.

    2011-01-01

    elasticity theory and (2) by using a dimensionally reduced shell-ring model. In the first approach the problem is solved with a fully automatic hp-adaptive finite element solver whereas the classical h-version of the finite element method is used

  13. CALIPSO lidar calibration at 532 nm: version 4 nighttime algorithm

    Science.gov (United States)

    Kar, Jayanta; Vaughan, Mark A.; Lee, Kam-Pui; Tackett, Jason L.; Avery, Melody A.; Garnier, Anne; Getzewich, Brian J.; Hunt, William H.; Josset, Damien; Liu, Zhaoyan; Lucker, Patricia L.; Magill, Brian; Omar, Ali H.; Pelon, Jacques; Rogers, Raymond R.; Toth, Travis D.; Trepte, Charles R.; Vernier, Jean-Paul; Winker, David M.; Young, Stuart A.

    2018-03-01

    Data products from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) on board Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) were recently updated following the implementation of new (version 4) calibration algorithms for all of the Level 1 attenuated backscatter measurements. In this work we present the motivation for and the implementation of the version 4 nighttime 532 nm parallel channel calibration. The nighttime 532 nm calibration is the most fundamental calibration of CALIOP data, since all of CALIOP's other radiometric calibration procedures - i.e., the 532 nm daytime calibration and the 1064 nm calibrations during both nighttime and daytime - depend either directly or indirectly on the 532 nm nighttime calibration. The accuracy of the 532 nm nighttime calibration has been significantly improved by raising the molecular normalization altitude from 30-34 km to the upper possible signal acquisition range of 36-39 km to substantially reduce stratospheric aerosol contamination. Due to the greatly reduced molecular number density and consequently reduced signal-to-noise ratio (SNR) at these higher altitudes, the signal is now averaged over a larger number of samples using data from multiple adjacent granules. Additionally, an enhanced strategy for filtering the radiation-induced noise from high-energy particles was adopted. Further, the meteorological model used in the earlier versions has been replaced by the improved Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2), model. An aerosol scattering ratio of 1.01 ± 0.01 is now explicitly used for the calibration altitude. These modifications lead to globally revised calibration coefficients which are, on average, 2-3 % lower than in previous data releases. Further, the new calibration procedure is shown to eliminate biases at high altitudes that were present in earlier versions and consequently leads to an improved representation of

  14. The reliability and validity of the Chinese version of nurses' self-concept questionnaire.

    Science.gov (United States)

    Cao, Xiao Yi; Liu, Xiao Hong; Tian, Lang; Guo, Yan Qin

    2013-05-01

    To examine the reliability and validity of the Chinese version of nurses' self-concept questionnaire. Nurses' self-concept is important to alleviate the current shortage of nurses. Nurses' self-concept questionnaire is an effective instrument to measure nurses' self-perception of professional competencies. However, the psychometric properties of the Chinese version have not been tested. A two-stage research design was used in this study. At Stage 1347 registered nurses were recruited to establish the psychometric properties of the Chinese version. At Stage 2, a confirmatory factor analysis was used to examine the extracted factor structure from Stage 1 with 1017 respondents as a sample. The internal consistency of the Chinese version was 0.95 and the test-retest reliability was 0.83. The exploratory factor analysis extracted six dimensions. The findings at Stage 2 showed an acceptable model fit and discriminant validity. The Chinese version was a significant predictor of Maslach Burnout Inventory (β = -0.58; P = 0.00). This study verified the psychometric properties of the Chinese version of nurses' self-concept questionnaire. The Chinese version of nurses' self-concept questionnaire will facilitate the evaluation of professional self-concept among nurses and help to develop the individualized self-concept strategies. © 2012 Blackwell Publishing Ltd.

  15. Psychometric properties of the Persian version of the Intensive and Critical Care Nursing Competence Scale version-1 (ICCN-CS-1).

    Science.gov (United States)

    Shouryabi, Ali Asghar; Ghahrisarabi, Alireza; Anboohi, Sima Zohari; Nasiri, Malihe; Rassouli, Maryam

    2017-11-01

    Nursing competence is highly related to patient outcomes and patient safety issues, especially in intensive care units. Competence assessment tools are needed specifically for intensive care nursing. This study was performed to determine psychometric properties of the Intensive and Critical Care Nursing Competence Scale version-1 between Iranian Nurses. The present study was a methodological research in which 289 nurses of Intensive Care Units from nine hospitals in Shahid Beheshti University of Medical Sciences in Tehran were selected between 2015 and 2016. The original version of the scale was translated into Persian and back-translated into English, and the comments of the developer were applied. The validity of the scale was the determined quality (content validity and face validity) and quantity (confirmatory factor analysis). Reliability of the scale was reported by Cronbach's alpha coefficient and Intra class Correlation Coefficient. SPSS-PC (v.21) and LISREL (v.8.5) were used to analyze the data. The intensive and critical care nursing competence scale version-1 is a self-assessment test that consists of 144 items and four domains which are the knowledge base, the skill base, the attitudes and values base and the experience base, which are divided into clinical competence and professional competence. Content and face validity was confirmed by 10 experts and 10 practitioner nurses in the intensive care units. In confirmatory factor analysis, all fitness indexes, except goodness of fit index (0.64), confirmed the four-factor structure of the ICCN-CS-1. The results of the factor analysis, load factor between 0.304 and 0.727 items was estimated; only 4 items out of 144 items, that were loaded were less than 0.3 due to high Cronbach's alpha coefficient (0.984-0.986), all items were preserved, no item was removed and 4 subscales of the original scale were confirmed. The results of this study indicated that the Persian version of "The Intensive and Critical Care

  16. Condiment: general synthesis of different versions

    International Nuclear Information System (INIS)

    Mangin, J.P.

    1990-01-01

    CONDIMENT is a code for the computation of ion migration and diffusion in areas close to radwaste storage facilities. This type of application was found to require a mesh pattern and boundary conditions different from the usual, which justifies the writing of a new code. A first version (version 2) only convers the migration of a single, non radioactive ion. The discretization, the selection of an implicit scheme, and the various boundary conditions are described. Physical quantities such as diffusion coefficient, porosity, retardation factor and permeability vary in space but not in time. A first extension consists of taking consideration radioactivity and filiation. Discretization with respect to time is modified, and a check performed on the original analytical solutions. In a second extension, consideration is given to non-linear adsorption, which makes it necessary to use the NEWTON-RAPHSON method. One can thus modelize the FREUNDLICH isotherms, in spite of the singular point at the origin. Diffusion, apparent porosity and permeability values can be changed as computed proceeds. The last extension is the introduction of two ions with the formation of precipitate. The formulation is derived from that used for non-linear adsorption, the precipitate playing a part similar to that of adsorbed concentration. Agreement with the original analytical solutions is verified. The case of migration with several interacting ions is approached from the theoretical standpoint. We described the discretization, which is similar to that in the first version, but involves many additional variables. Numerical stability is shown to be unconditional [fr

  17. GEMPAK 5.1 - A GENERAL METEOROLOGICAL PACKAGE (VAX VMS VERSION)

    Science.gov (United States)

    Des, Jardins M. L.

    1994-01-01

    GEMPAK is a general meteorological software package developed at NASA/Goddard Space Flight Center. It includes programs to analyze and display surface, upper-air, and gridded data, including model output. There are very general programs to list, edit, and plot data on maps, to display profiles and time series, to draw and fill contours, to draw streamlines, to plot symbols for clouds, sky cover, and pressure tendency, and draw cross sections in the case of gridded data and sounding data. In addition, there are Barnes objective analysis programs to grid surface and upper-air data. The programs include the capabilities to derive meteorological parameters from those found in the dataset, to perform vertical interpolations of sounding data to different coordinate systems, and to compute an extensive set of gridded diagnostic quantities by specifying various nested combinations of scalars and vector arithmetic, algebraic, and differential operators. The GEMPAK 5.1 graphics/transformation subsystem, GEMPLT, provides device-independent graphics. GEMPLT also has the capability to display output in a variety of map projections or overlaid on satellite imagery. GEMPAK 5.1 is written in FORTRAN 77 and C-language and has been implemented on VAX computers under VMS and on computers running the UNIX operating system. During installation and normal use, this package occupies approximately 100Mb of hard disk space. The UNIX version of GEMPAK includes drivers for several graphic output systems including MIT's X Window System (X11,R4), Sun GKS, PostScript (color and monochrome), Silicon Graphics, and others. The VMS version of GEMPAK also includes drivers for several graphic output systems including PostScript (color and monochrome). The VMS version is delivered with the object code for the Transportable Applications Environment (TAE) program, version 4.1 which serves as a user interface. A color monitor is recommended for displaying maps on video display devices. Data for rendering

  18. Integrated Global Radiosonde Archive (IGRA) Version 2

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Integrated Global Radiosonde Archive (IGRA) Version 2 consists of quality-controlled radiosonde observations of temperature, humidity, and wind at stations across...

  19. ICRAF Species Switchboard. Version 1.2

    DEFF Research Database (Denmark)

    Kindt, R.; Ordonez, J.; Smith, E.

    2015-01-01

    The current version of the Agroforestry Species Switchboard documents the presence of a total of 26,135 plant species (33,813 species including synonyms) across 19 web-based databases. When available, hyperlinks to information on the selected species in particular databases are provided. In total...

  20. Hong Kong faces uncertain future as oil supply centre

    International Nuclear Information System (INIS)

    McDonald, Paul

    1997-01-01

    Hong Kong's first day under Chinese rule, 1 July 1997, was not exactly auspicious. A celebratory parade organized by the Chinese was washed out by torrential rain, and the grand finale of a firework display, described as 'a bold statement..... embodying confidence in the future of Hong Kong' fizzled out when one of the firework barges caught fire. The omens are not necessarily good for the territory's oil industry either. (author)

  1. Verification of the 2.00 WAPPA-B [Waste Package Performance Assessment-B version] code

    International Nuclear Information System (INIS)

    Tylock, B.; Jansen, G.; Raines, G.E.

    1987-07-01

    The old version of the Waste Package Performance Assessment (WAPPA) code has been modified into a new code version, 2.00 WAPPA-B. The input files and the results for two benchmarks at repository conditions are fully documented in the appendixes of the EA reference report. The 2.00 WAPPA-B version of the code is suitable for computation of barrier failure due to uniform corrosion; however, an improved sub-version, 2.01 WAPPA-B, is recommended for general use due to minor errors found in 2.00 WAPPA-B during its verification procedures. The input files and input echoes have been modified to include behavior of both radionuclides and elements, but the 2.00 WAPPA-B version of the WAPPA code is not recommended for computation of radionuclide releases. The 2.00 WAPPA-B version computes only mass balances and the initial presence of radionuclides that can be released. Future code development in the 3.00 WAPPA-C version will include radionuclide release computations. 19 refs., 10 figs., 1 tab

  2. MORSE - E. A new version of the MORSE code

    International Nuclear Information System (INIS)

    Ponti, C.; Heusden, R. van.

    1974-12-01

    This report describes a version of the MORSE code which has been written to facilitate the practical use of this programme. MORSE-E is a ready-to-use version that does not require particular programming efforts to adapt the code to the problem to be solved. It treats source volumes of different geometrical shapes. MORSE-E calculates the flux of particles as the sum of the paths travelled within a given volume; the corresponding relative errors are also provided

  3. [Development of a Japanese version of the TALE scale].

    Science.gov (United States)

    Ochiai, Tsutomu; Oguchi, Takashi

    2013-12-01

    The Thinking About Life Experiences (TALE) Scale (Bluck & Alea, 2011) has three subscales that assess the self, social, and directive functions of autobiographical memory. This study constructs a Japanese version of the TALE Scale and examines its reliability and validity. Fifteen items that assess the three functions of autobiographical memory were translated into Japanese. We conducted an online investigation with 600 men and women between 20-59 years of age. In Study 1, exploratory and confirmatory factor analysis identified that the three-factor structure of the Japanese version of the TALE Scale was the same as the original TALE Scale. Sufficient internal consistency of the scale was found, and the construct validity of the scale was supported by correlation analysis. Study 2 confirmed that the test-retest reliabilities of the three subscales were sufficient. Thus, this Japanese version of the TALE Scale is useful to assess autobiographical memory functions in Japan.

  4. [Consequences of errors in the translation of questionnaires: Spanish version of Downton index].

    Science.gov (United States)

    Aranda-Gallardo, M; Morales-Asencio, J M; Canca-Sánchez, J C; Morales-Fernández, Á; Enríquez de Luna-Rodríguez, M; Moya-Suarez, A B; Mora-Banderas, A M; Pérez-Jiménez, C; Barrero-Sojo, S

    2015-01-01

    The application of screening tools to detect the risk of falls in hospitalized patients is in general use. During the development of a systematic review a serious disparity in three items of the Spanish version of the Downton index was detected, compared to the original version. The aim of this study was to determine the impact of this error and to compare the estimated risk of falls with each of these versions, its validity and internal consistency. A descriptive cross-sectional study in acute hospitalised patients was performed during 2011 in Hospital Costa del Sol, Marbella. The patients' risk of falling was assessed by the Spanish version of the Downton index, and then it was re-calculated according to the items in the original version. Sensitivity, specificity and Cronbach's alpha were calculated. Application of the original version of the index reduced the number of patients classified as "high risk" of falling by 24.2%. With the Spanish version of the tool, the possibility of being classed as "high risk" of falling was considerably 3.3 times higher (OR: 3.3). Both versions of the Downton index showed low accuracy and diagnostic validity. The sensitivity of the original scale was 28% and specificity of 82%. Its internal consistency was low (Cronbach's alpha: .51). The Downton index, given its poor accuracy and diagnostic validity, low internal consistency, and the significant error observed in its Spanish translation, is not the most appropriate tool to assess the risk of falls in hospitalised acute patients. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.

  5. [Guidelines on urolithiasis: an outline and effective use of the revised version].

    Science.gov (United States)

    Kohri, Kenjiro; Suzuki, Koji

    2012-12-01

    Progress has been made in the diagnosis and treatment of urolithiasis over the last 10 years, after the first version of the Guidelines on Urolithiasis was published in December 2002. Considering such a situation, the revised version is due for publication soon. At this symposium, 3 persons who were engaged in the revision of the guidelines presented its digest. The revised version is characterized by the adoption of a "Frequently asked questions style", aiming to facilitate its usage as a reference book or dictionary readers can refer to when a question is raised in practice. It may be possible to further promote the medical treatment of urolithiasis by effectively using this in combination with the relatively textbook-like first version.

  6. A validation analysis of two self-reported HAM-D6 versions

    DEFF Research Database (Denmark)

    Bech, P; Wilson, P; Wessel, T

    2009-01-01

    the unidimensionality of this administration form in patients with mild-to-moderate depression. METHOD: The item response theory analysis of Mokken was used to test the unidimensionality of both the Interactive Voice Recording System (IVRS) version of the HAM-D(6) and a paper-and-pencil self-reported version (S-HAM-D(6......OBJECTIVE: The six items of the clinician-administrated Hamilton Depression Scale (HAM-D(6)) cover the core items of depressive states reflecting the antidepressive effect of medication. In this study, the two self-reported versions of the HAM-D(6) have been psychometrically validated to ensure...

  7. Code development and analysis program. RELAP4/MOD7 (Version 2): user's manual

    International Nuclear Information System (INIS)

    1978-08-01

    This manual describes RELAP4/MOD7 (Version 2), which is the latest version of the RELAP4 LPWR blowdown code. Version 2 is a precursor to the final version of RELAP4/MOD7, which will address LPWR LOCA analysis in integral fashion (i.e., blowdown, refill, and reflood in continuous fashion). This manual describes the new code models and provides application information required to utilize the code. It must be used in conjunction with the RELAP4/MOD5 User's Manual (ANCR-NUREG-1335, dated September 1976), and the RELAP4/MOD6 User's Manual

  8. Computerized transportation model for the NRC Physical Protection Project. Versions I and II

    International Nuclear Information System (INIS)

    Anderson, G.M.

    1978-01-01

    Details on two versions of a computerized model for the transportation system of the NRC Physical Protection Project are presented. The Version I model permits scheduling of all types of transport units associated with a truck fleet, including truck trailers, truck tractors, escort vehicles and crews. A fixed-fleet itinerary construction process is used in which iterations on fleet size are required until the service requirements are satisfied. The Version II model adds an aircraft mode capability and provides for a more efficient non-fixed-fleet itinerary generation process. Test results using both versions are included

  9. FASTDART - A fast, accurate and friendly version of DART code

    International Nuclear Information System (INIS)

    Rest, Jeffrey; Taboada, Horacio

    2000-01-01

    A new enhanced, visual version of DART code is presented. DART is a mechanistic model based code, developed for the performance calculation and assessment of aluminum dispersion fuel. Major issues of this new version are the development of a new, time saving calculation routine, able to be run on PC, a friendly visual input interface and a plotting facility. This version, available for silicide and U-Mo fuels, adds to the classical accuracy of DART models for fuel performance prediction, a faster execution and visual interfaces. It is part of a collaboration agreement between ANL and CNEA in the area of Low Enriched Uranium Advanced Fuels, held by the Implementation Arrangement for Technical Exchange and Cooperation in the Area of Peaceful Uses of Nuclear Energy. (author)

  10. School version of ESTE EU

    International Nuclear Information System (INIS)

    Carny, P.; Suchon, D.; Chyly, M.; Smejkalova, E.; Fabova, V.

    2008-01-01

    ESTE EU is information system and software for radiological impacts assessment to the territory of the country in case of radiation accident inside/outside of the country .The program enables to model dispersion of radioactive clouds in small-scale and meso-scale. The system enables the user to estimate prediction of the source term (release to the atmosphere ) for any point of radiation/nuclear accident in Europe (for any point of the release, but especially for the sites of European power reactors ). The system enables to utilize results of real radiological monitoring in the process of source term estimation. Radiological impacts of release to the atmosphere are modelled and calculated across the Europe and displayed in the geographical information system (GIS). The school version of ESTE EU is intended for students of the universities which are interested in or could work in the field of emergency response, radiological and nuclear accidents, dispersion modelling, radiological impacts calculation and urgent or preventive protective measures implementation. The school version of ESTE EU is planned to be donated to specialized departments of faculties in Slovakia, Czech Republic, etc. System can be fully operated in Slovak, Czech or English language. (authors)

  11. School version of ESTE EU

    International Nuclear Information System (INIS)

    Carny, P.; Suchon, D.; Chyly, M.; Smejkalova, E.; Fabova, V.

    2009-01-01

    ESTE EU is information system and software for radiological impacts assessment to the territory of the country in case of radiation accident inside/outside of the country .The program enables to model dispersion of radioactive clouds in small-scale and meso-scale. The system enables the user to estimate prediction of the source term (release to the atmosphere ) for any point of radiation/nuclear accident in Europe (for any point of the release, but especially for the sites of European power reactors ). The system enables to utilize results of real radiological monitoring in the process of source term estimation. Radiological impacts of release to the atmosphere are modelled and calculated across the Europe and displayed in the geographical information system (GIS). The school version of ESTE EU is intended for students of the universities which are interested in or could work in the field of emergency response, radiological and nuclear accidents, dispersion modelling, radiological impacts calculation and urgent or preventive protective measures implementation. The school version of ESTE EU is planned to be donated to specialized departments of faculties in Slovakia, Czech Republic, etc. System can be fully operated in Slovak, Czech or English language. (authors)

  12. Implementation of the external cephalic version in breech delivery. Dutch national implementation study of external cephalic version

    NARCIS (Netherlands)

    Vlemmix, F.; Rosman, A N; Fleuren, M A H; Rijnders, M E B; Beuckens, A.; Haak, M.C.; Akerboom, B.M.C.; Bais, J.M.J.; Kuppens, S M I; Papatsonis, D.N.M.; Opmeer, Brent C; van der Post, J.A.M.; Mol, B.W.J.; Kok, M

    2010-01-01

    Background: Breech presentation occurs in 3 to 4% of all term pregnancies. External cephalic version (ECV) is proven effective to prevent vaginal breech deliveries and therefore it is recommended by clinical guidelines of the Royal Dutch Organisation for Midwives (KNOV) and the Dutch Society for

  13. Implementation of the external cephalic version in breech delivery Dutch national implementation study of external cephalic version

    NARCIS (Netherlands)

    Vlemmix, Floortje; Rosman, Ageeth N.; Fleuren, Margot A. H.; Rijnders, Marlies E. B.; Beuckens, Antje; Haak, Monique C.; Akerboom, Bettina M. C.; Bais, Joke M. J.; Kuppens, Simone M. I.; Papatsonis, Dimitri N.; Opmeer, Brent C.; van der Post, Joris A. M.; Mol, Ben Willem J.; Kok, Marjolein

    2010-01-01

    ABSTRACT: BACKGROUND: Breech presentation occurs in 3 to 4 % of all term pregnancies. External cephalic version (ECV) is proven effective to prevent vaginal breech deliveries and therefore it is recommended by clinical guidelines of the Royal Dutch Organisation for Midwives (KNOV) and the Dutch

  14. Validation of the Persian Version of the Problematic Internet Use Questionnaire (PIUQ).

    Science.gov (United States)

    Ranjbar, Hadi; Thatcher, Andrew; Greyling, Michael; Arab, Mansour; Nasri, Nahid

    2014-10-01

    The most commonly used instrument for the research and treatment of excessive internet use is Young's Internet Addiction Test (IAT). While the IAT has been translated to several languages (including Persian) and has demonstrated good psychometric properties across several independent studies, there is still a room for alternative assessment instruments. This study reports a validation of the Persian version of the Problematic Internet Use Questionnaire (PIUQ). A sample (n = 296) from Kerman, Iran was administered the translated Persian version of the PIUQ as well as the Persian version of the University of California, Los Angeles (UCLA) Loneliness scale, Satisfaction With Life scale, and questions related to use of technology and the internet. Analyses using confirmatory and exploratory factor analyses demonstrated that the Persian version of the PIUQ had good internal reliability and concurrent validity (with loneliness and satisfaction with life), but they also had an alternative factor structure that did not support the original factor structure. The Persian version of the PIUQ produced adequate psychometric properties (internal reliability and concurrent validity), but care should be taken in the interpretation of the factor structure.

  15. Comparison between RELAP5 versions for a two-phase natural circulation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Braz Filho, Francisco A.; Ribeiro, Guilherme B.; Sabundjian, Gaianê; Caldeira, Alexandre D., E-mail: fbraz@ieav.cta.br, E-mail: gbribeiro@ieav.cta.br, E-mail: alexdc@ieav.cta.br, E-mail: gdjian@ipen.br [Instituto de Estudos Avançados (IEAv), São José dos Campos, SP (Brazil). Div. de Energia Nuclear; Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    RELAP5 is one of the most used numerical tools to predict thermal-hydraulic and neutronic phenomena in nuclear reactors. RELAP5-3D is the latest version of this software family, but RELAP5-mod3 is still widely used in Brazilian research institutes and it is also used as benchmark for several nuclear applications. Among these applications, the use of passive heat transfer mechanisms, such as natural circulation, has drawn attention of several studies, especially after the Fukushima-Daiichi accident. Considering this aforementioned aspect, this study proposes a comparison of RELAP5-3D and RELAP5-mod3 versions, focusing on a two-phase natural circulation loop. For comparison purposes, an experimental data set is part of the analysis. Results showed that during the single-phase regime, the temperature difference between versions is negligible. However, when the two-phase flow regime takes place, different wavelengths and amplitudes of flow instabilities were obtained for each version. When compared to the experimental data set, the RELAP5-3D version provided the best prediction results. (author)

  16. IGT-Open: An open-source, computerized version of the Iowa Gambling Task.

    Science.gov (United States)

    Dancy, Christopher L; Ritter, Frank E

    2017-06-01

    The Iowa Gambling Task (IGT) is commonly used to understand the processes involved in decision-making. Though the task was originally run without a computer, using a computerized version of the task has become typical. These computerized versions of the IGT are useful, because they can make the task more standardized across studies and allow for the task to be used in environments where a physical version of the task may be difficult or impossible to use (e.g., while collecting brain imaging data). Though these computerized versions of the IGT have been useful for experimentation, having multiple software implementations of the task could present reliability issues. We present an open-source software version of the Iowa Gambling Task (called IGT-Open) that allows for millisecond visual presentation accuracy and is freely available to be used and modified. This software has been used to collect data from human subjects and also has been used to run model-based simulations with computational process models developed to run in the ACT-R architecture.

  17. Korean Version of Inventory of Complicated Grief Scale: Psychometric Properties in Korean Adolescents.

    Science.gov (United States)

    Han, Doug Hyun; Lee, Jung Jae; Moon, Duk-Soo; Cha, Myoung-Jin; Kim, Min A; Min, Seonyeong; Yang, Ji Hoon; Lee, Eun Jeong; Yoo, Seo Koo; Chung, Un-Sun

    2016-01-01

    We aimed to validate the Inventory of Complicated Grief (ICG)-Korean version among 1,138 Korean adolescents, representing a response rate of 57% of 1,997 students. Participants completed a set of questionnaires including demographic variables (age, sex, years of education, experience of grief), the ICG, the Children's Depression Inventory (CDI) and the Lifetime Incidence of Traumatic Events-Child (LITE-C). Exploratory factor analysis was performed to determine whether the ICG items indicated complicated grief in Korean adolescents. The internal consistency of the ICG-Korean version was Cronbach's α=0.87. The test-retest reliability for a randomly selected sample of 314 participants in 2 weeks was r=0.75 (PKaiser-Meyer-Olkin Measure of Sampling Adequacy=0.911; Bartlett's Test of Sphericity, χ(2)=13,144.7, P<0.001). After omission of 3 items, the value of Cronbach's α increased from 0.87 for the 19-item ICG-Korean version to 0.93 for the 16-item ICG-Korean version. These results suggest that the ICG is a useful tool in assessing for complicated grief in Korean adolescents. However, the 16-item version of the ICG appeared to be more valid compared to the 19-item version of the ICG. We suggest that the 16-item version of the ICG be used to screen for complicated grief in Korean adolescents.

  18. ASPEN Version 3.0

    Science.gov (United States)

    Rabideau, Gregg; Chien, Steve; Knight, Russell; Schaffer, Steven; Tran, Daniel; Cichy, Benjamin; Sherwood, Robert

    2006-01-01

    The Automated Scheduling and Planning Environment (ASPEN) computer program has been updated to version 3.0. ASPEN is a modular, reconfigurable, application software framework for solving batch problems that involve reasoning about time, activities, states, and resources. Applications of ASPEN can include planning spacecraft missions, scheduling of personnel, and managing supply chains, inventories, and production lines. ASPEN 3.0 can be customized for a wide range of applications and for a variety of computing environments that include various central processing units and random access memories.

  19. The ESA/ESO/NASA Photoshop fits Liberator Version 2

    Science.gov (United States)

    Christensen, L. L.; Nielsen, L. H.; Nielsen, K. K.; Johansen, T.

    2005-12-01

    Since the fi rst version of the FITS Liberator software was released on the 8th July 2004 more than 50,000 people worldwide have looked over the scientists' shoulders and worked with digital images from telescopes in space and on the ground themselves. In this way the Liberator has become the `industry standard' for the production of astronomical colour images. The new version 2 of the software has recently been released and opens up a signifi cant number of new possibilities.

  20. The harm argument against surrogacy revisited: two versions not to forget.

    Science.gov (United States)

    Agnafors, Marcus

    2014-08-01

    It has been a common claim that surrogacy is morally problematic since it involves harm to the child or the surrogate-the harm argument. Due to a growing body of empirical research, the harm argument has seen a decrease in popularity, as there seems to be little evidence of harmful consequences of surrogacy. In this article, two revised versions of the harm argument are developed. It is argued that the two suggested versions of the harm argument survive the current criticism against the standard harm argument. The first version argues that the child is harmed by being separated from the gestational mother. The second version directs attention to the fact that surrogacy involves great incentives to keep the gestational mother's level of maternal-fetal attachment low, which tend to increase the risk of harm to the child. While neither of the two arguments is conclusive regarding the moral status of surrogacy, both constitute important considerations that are often ignored.

  1. The FORM version of MINCER

    International Nuclear Information System (INIS)

    Larin, S.A.; Academy of Sciences of the USSR, Moscow; Tkachov, F.V.; McGill Univ., Montreal, PQ; Academy of Sciences of the USSR, Moscow; Vermaseren, J.A.M.

    1991-01-01

    The program MINCER for massless three-loop Feynman diagrams of the propagator type has been reprogrammed in the language of FORM. The new version is thoroughly optimized and can be run from a utility like the UNIX make, which allows one to conveniently process large numbers of diagrams. It has been used for some calculations that were previously not practical. (author). 22 refs.; 14 figs

  2. DEMAID - A DESIGN MANAGER'S AID FOR INTELLIGENT DECOMPOSITION (MACINTOSH VERSION)

    Science.gov (United States)

    Rogers, J. L.

    1994-01-01

    effects of an output with respect to a change in a particular input. The second method traces backward to determine what modules must be re-executed if the output of a module must be recomputed. DeMAID is available in three machine versions: a Macintosh version which is written in Symantec's Think C 3.01, a Sun version, and an SGI IRIS version, both of which are written in C language. The Macintosh version requires system software 6.0.2 or later and CLIPS 4.3. The source code for the Macintosh version will not compile under version 4.0 of Think C; however, a sample executable is provided on the distribution media. QuickDraw is required for plotting. The Sun version requires GKS 4.1 graphics libraries, OpenWindows 3, and CLIPS 4.3. The SGI IRIS version requires CLIPS 4.3. Since DeMAID is not compatible with CLIPS 5.0 or later, the source code for CLIPS 4.3 is included on the distribution media; however, the documentation for CLIPS 4.3 is not included in the documentation package for DeMAID. It is available from COSMIC separately as the documentation for MSC-21208. The standard distribution medium for the Macintosh version of DeMAID is a set of four 3.5 inch 800K Macintosh format diskettes. The standard distribution medium for the Sun version of DeMAID is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. The standard distribution medium for the IRIS version is a .25 inch IRIX compatible streaming magnetic tape cartridge in UNIX tar format. All versions include sample input. DeMAID was originally developed for use on VAX VMS computers in 1989. The Macintosh version of DeMAID was released in 1991 and updated in 1992. The Sun version of DeMAID was released in 1992 and updated in 1993. The SGI IRIS version was released in 1993.

  3. DEMAID - A DESIGN MANAGER'S AID FOR INTELLIGENT DECOMPOSITION (SUN VERSION)

    Science.gov (United States)

    Rogers, J. L.

    1994-01-01

    effects of an output with respect to a change in a particular input. The second method traces backward to determine what modules must be re-executed if the output of a module must be recomputed. DeMAID is available in three machine versions: a Macintosh version which is written in Symantec's Think C 3.01, a Sun version, and an SGI IRIS version, both of which are written in C language. The Macintosh version requires system software 6.0.2 or later and CLIPS 4.3. The source code for the Macintosh version will not compile under version 4.0 of Think C; however, a sample executable is provided on the distribution media. QuickDraw is required for plotting. The Sun version requires GKS 4.1 graphics libraries, OpenWindows 3, and CLIPS 4.3. The SGI IRIS version requires CLIPS 4.3. Since DeMAID is not compatible with CLIPS 5.0 or later, the source code for CLIPS 4.3 is included on the distribution media; however, the documentation for CLIPS 4.3 is not included in the documentation package for DeMAID. It is available from COSMIC separately as the documentation for MSC-21208. The standard distribution medium for the Macintosh version of DeMAID is a set of four 3.5 inch 800K Macintosh format diskettes. The standard distribution medium for the Sun version of DeMAID is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. The standard distribution medium for the IRIS version is a .25 inch IRIX compatible streaming magnetic tape cartridge in UNIX tar format. All versions include sample input. DeMAID was originally developed for use on VAX VMS computers in 1989. The Macintosh version of DeMAID was released in 1991 and updated in 1992. The Sun version of DeMAID was released in 1992 and updated in 1993. The SGI IRIS version was released in 1993.

  4. Traduire Flaubert : Madame Bovary en version roumaine

    Directory of Open Access Journals (Sweden)

    Florica Courriol

    2012-02-01

    Full Text Available Cette communication est le résultat d'une analyse traductionnelle visant à réévaluer une version roumaine de Madame Bovary des années soixante-dix (Doamna Bovary traduit par Demostene Botez à travers le travail concret sur le texte avec les étudiants d'un mastère. De multiples anomalies ayant été ainsi décelées, j'ai été amenée à retraduire ce grand classique. Il m'a semblé profitable à la recherche flaubertienne d'exposer les difficultés et leurs résolutions, d'ordre purement linguistique ou civilisationnel, que l'on se place sur le plan de la lecture (compréhension du texte ou sur celui du rendu dans la langue d'arrivée. Le choix des points litigieux ne se limite pas au simple discours mais touche aussi à la problématique des noms propres (peut-on les traduire ? faut-il avoir recours aux fameuses notes de traducteur ? et, en conséquence logique, à celle du titre. Les exemples concrets viennent étayer une pratique traduisante et la mettre en relation avec la critique, l'histoire littéraire et la création flaubertienne dans son ensemble.I intend to address in this paper the concrete problems I encountered when translating into Romanian FLAUBERT’s major work, Madame Bovary. First of all, its nature of retranslation has to be specified, since an existing version, published in the 1970s by a Romanian poet (Demostene Botez, was in fact in circulation when I started working on the original text. This previous translation was probably the result of a collective operation, as the split rhythm suggests at several points. In the meantime, other publishers saw fit to print additional versions in great haste. However, a mere examination of the problematic passages is sufficient enough to realize that the authors of the new versions only limited themselves to take up the first one. They improved the text here and there, “updated” some expressions, while keeping the glaring errors of Botez’s version.

  5. Moxibustion for breech version: a randomized controlled trial.

    Science.gov (United States)

    Guittier, Marie-Julia; Pichon, Michelle; Dong, Hongguang; Irion, Olivier; Boulvain, Michel

    2009-11-01

    To estimate the efficacy of moxibustion between 34 and 38 weeks of gestation to facilitate the cephalic version of fetuses in breech presentation and the acceptability of this method by women. We conducted a randomized controlled trial in a Swiss university hospital maternity unit. We proposed to stimulate the acupoint BL 67 by moxibustion daily for 2 weeks for 212 consenting women between 34 and 36 weeks of gestation with a single fetus in breech presentation. We did the intervention three times weekly in the hospital and a teaching session and information leaflet on the technique for additional daily therapy at home. The control group received expectant management care. The availability of external cephalic version was maintained for both groups. The main outcome measure was the comparison of the proportion of women with cephalic presentation at delivery. Baseline characteristics were similar between groups, except more nulliparous women were randomized to moxibustion. The percentage of versions was similar between groups: 18% in the moxibustion group compared with 16% in the control group (relative risk 1.12, 95% confidence interval 0.62 to 2.03). Adjustment for the imbalance in parity did not change these results. The frequency of cesarean delivery was similar (64% compared with 58% in the moxibustion group and the control group, respectively). Acceptability of the intervention and women's perceptions of moxibustion were favorable. We observed no beneficial effect of moxibustion to facilitate the cephalic version of fetuses in breech presentation. Despite this lack of proven effectiveness, women had positive opinions on the intervention. ClinicalTrials.gov, www.clinicaltrials.gov,NCT00890474. I.

  6. Development of the Brazilian version of the Child Hayling Test

    Directory of Open Access Journals (Sweden)

    Larissa de Souza Siqueira

    Full Text Available Abstract Introduction: The Hayling Test assesses the components of initiation, inhibition, cognitive flexibility and verbal speed by means of a sentence completion task. This study presents the process of developing the Brazilian version of the Child Hayling Test (CHT and reports evidence of its content validity. Methods: 139 people took part in the study. The adaptation was performed by seven translators and 12 specialist judges. An initial sample of 92 healthy children was recruited to test a selection of sentences adapted from previous adult and pediatric versions of the instrument, and a sample of 28 healthy children was recruited for pilot testing of the final version. The instrument was developed in seven stages: 1 translation, 2 back-translation, 3 comparison of translated versions, 4 preparation of new stimuli, 5 data collection with healthy children to analyze comprehension of the stimuli and analyses by the authors against the psycholinguistic criteria adopted, 6 analyses conducted by judges who are specialists in neuropsychology or linguistics, and 7 the pilot study. Results: Twenty-four of the 72 sentences constructed were selected on the basis of 70-100% agreement between judges evaluating what they assessed and level of comprehensibility. The pilot study revealed better performance by older children, providing evidence of the instrument's sensitivity to developmental factors. Conclusions: Future studies employing this version of CHT with clinical pediatric populations who have frontal lesions and dysfunctions and in related areas are needed to test functional and differential diagnoses of preserved or impaired executive functions.

  7. The use of stereotypes and individuating information in political person perception.

    Science.gov (United States)

    Crawford, Jarret T; Jussim, Lee; Madon, Stephanie; Cain, Thomas R; Stevens, Sean T

    2011-04-01

    This article introduces the political person perception model, which identifies conditions under which perceivers rely on stereotypes (party membership), individuating information (issue position), or both in political person perception. Three studies supported the model's predictions. Study 1 showed that perceivers gave primacy to target information that was narrowly relevant to a judgment, whether that information was stereotypic or individuating. Study 2 found that perceivers relied exclusively on individuating information when it was narrowly relevant to the judgment and relied on both stereotype and individuating information when individuating information was not narrowly relevant to the judgment but did imply a political ideology. Study 3 replicated these findings in a more ecologically valid context and showed that people relied on party information in the absence of narrowly relevant policy positions and when individuating information did not imply a political ideology. Implications for political person perception and theories of stereotyping are discussed.

  8. Space shuttle general purpose computers (GPCs) (current and future versions)

    Science.gov (United States)

    1988-01-01

    Current and future versions of general purpose computers (GPCs) for space shuttle orbiters are represented in this frame. The two boxes on the left (AP101B) represent the current GPC configuration, with the input-output processor at far left and the central processing unit (CPU) at its side. The upgraded version combines both elements in a single unit (far right, AP101S).

  9. Erzurum in the Turkmen Version of Koroglu Legend

    Directory of Open Access Journals (Sweden)

    Mustafa Serbes

    2016-03-01

    Full Text Available In the Turkmen version of Koroglu Legend, there exist lots of country, city and place names belonging to the Turkish world and neighboring folks. The places in the legend are not only composed of Turkmen lands and neighbors, but there are other extraordinary places like Kaf Mountain as well. The hero of the legend, Koroglu, has connections with neighboring places because of various reasons. In the most of the sections, Koroglu organizes wars against the neighboring countries and cities. He imposes a tax on some of those countries and cities. Arzılum (Erzurum is also one of the cities in which Koroglu is interested. Although it’s far from Turkmen geography, Erzurum takes place in the Turkmen version of the legend. The city is described in details. In the most sections of the legend, the name and the characteristics of the city, particularly “Erhasan and Tellihan” take place. In this study, the materials related to Erzurum, which is located in twenty one sections of the Turkmen version of Koroglu Legend, have been analyzed. The information given about the city has been evaluated, particularly by moving from the section of “Erhasan and Tellihan”.

  10. Development and Validation of the Pediatric Medical Complexity Algorithm (PMCA) Version 3.0.

    Science.gov (United States)

    Simon, Tamara D; Haaland, Wren; Hawley, Katherine; Lambka, Karen; Mangione-Smith, Rita

    2018-02-26

    To modify the Pediatric Medical Complexity Algorithm (PMCA) to include both International Classification of Diseases, Ninth and Tenth Revisions, Clinical Modification (ICD-9/10-CM) codes for classifying children with chronic disease (CD) by level of medical complexity and to assess the sensitivity and specificity of the new PMCA version 3.0 for correctly identifying level of medical complexity. To create version 3.0, PMCA version 2.0 was modified to include ICD-10-CM codes. We applied PMCA version 3.0 to Seattle Children's Hospital data for children with ≥1 emergency department (ED), day surgery, and/or inpatient encounter from January 1, 2016, to June 30, 2017. Starting with the encounter date, up to 3 years of retrospective discharge data were used to classify children as having complex chronic disease (C-CD), noncomplex chronic disease (NC-CD), and no CD. We then selected a random sample of 300 children (100 per CD group). Blinded medical record review was conducted to ascertain the levels of medical complexity for these 300 children. The sensitivity and specificity of PMCA version 3.0 was assessed. PMCA version 3.0 identified children with C-CD with 86% sensitivity and 86% specificity, children with NC-CD with 65% sensitivity and 84% specificity, and children without CD with 77% sensitivity and 93% specificity. PMCA version 3.0 is an updated publicly available algorithm that identifies children with C-CD, who have accessed tertiary hospital emergency department, day surgery, or inpatient care, with very good sensitivity and specificity when applied to hospital discharge data and with performance to earlier versions of PMCA. Copyright © 2018 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  11. PUMA Version 6 Multiplatform with Facilities to be coupled with other Simulation Models

    International Nuclear Information System (INIS)

    Grant, Carlos

    2013-01-01

    PUMA is a code for nuclear reactor calculation used in all nuclear installations in Argentina for simulation of fuel management, power cycles and transient events by means of spatial kinetic diffusion theory in 3D. For the versions used up to now the WINDOWS platform was used with very good results. Nowadays PUMA must work in different operative systems, LINUX among others, and must also have facilities to be coupled with other models. For this reason this new version was reprogrammed in ADA, language oriented to a safe programming and be found in any operative system. In former versions PUMA was executed through macro instructions written in LOGO. For this version it is possible to use also PYTHON, which makes also possible the access in execution time to internal data of PUMA. The use of PYTHON allows a easy way to couple PUMA with other codes. The possibilities of this new version of PUMA are shown by means of examples of input data and process control using PYTHON and LOGO. It is discussed the implementation of this methodology in other codes to be coupled with PUMA for versions run in WINDOWS and LINUX. (author)

  12. [External cephalic version in cases of breech presentation: renaissance of a well-known procedure?].

    Science.gov (United States)

    Schmidt, M; Callies, R; Kuhn, U; Willruth, A; Kimmig, R

    2009-01-01

    About 3-4% of all pregnant women will have a fetus presenting by the breech at term. External cephalic version offers the opportunity to reduce the rate of caesarean sections caused by breech presentation. We analysed retrospectively 51 cases of external cephalic version at our clinic. External cephalic version was performed 51 times between 37 and 41 weeks of pregnancy. External cephalic version was successful in 32/51 cases (62,7%) with a consecutive rate of vaginal delivery of 71,9%. The best results were seen at 37 weeks of pregnancy with 81,25% of successful versions followed by 76,9% of vaginal deliveries. Complications were rare. There was just 1 case of emergency caesarean section due to persisting fetal bradycardia. External cephalic version is an effective and safe treatment to enable vaginal delivery of cephalic presentation. For this operation, 37 weeks of pregnancy can be considered the best time. 2009 S. Karger AG, Basel.

  13. Validity and Reliability of Farsi Version of Youth Sport Environment Questionnaire.

    Science.gov (United States)

    Eshghi, Mohammad Ali; Kordi, Ramin; Memari, Amir Hossein; Ghaziasgar, Ahmad; Mansournia, Mohammad-Ali; Zamani Sani, Seyed Hojjat

    2015-01-01

    The Youth Sport Environment Questionnaire (YSEQ) had been developed from Group Environment Questionnaire, a well-known measure of team cohesion. The aim of this study was to adapt and examine the reliability and validity of the Farsi version of the YSEQ. This version was completed by 455 athletes aged 13-17 years. Results of confirmatory factor analysis indicated that two-factor solution showed a good fit to the data. The results also revealed that the Farsi YSEQ showed high internal consistency, test-retest reliability, and good concurrent validity. This study indicated that the Farsi version of the YSEQ is a valid and reliable measure to assess team cohesion in sport setting.

  14. SHABERTH - ANALYSIS OF A SHAFT BEARING SYSTEM (CRAY VERSION)

    Science.gov (United States)

    Coe, H. H.

    1994-01-01

    shear forces in the inlet zone of lubricated contacts, which accounts for the degree of lubricant film starvation; modeling normal and friction forces between a ball and a cage pocket, which account for the transition between the hydrodynamic and elastohydrodynamic regimes of lubrication; and a model of the effect on fatigue life of the ratio of the EHD plateau film thickness to the composite surface roughness. SHABERTH is intended to be as general as possible. The models in SHABERTH allow for the complete mathematical simulation of real physical systems. Systems are limited to a maximum of five bearings supporting the shaft, a maximum of thirty rolling elements per bearing, and a maximum of one hundred temperature nodes. The SHABERTH program structure is modular and has been designed to permit refinement and replacement of various component models as the need and opportunities develop. A preprocessor is included in the IBM PC version of SHABERTH to provide a user friendly means of developing SHABERTH models and executing the resulting code. The preprocessor allows the user to create and modify data files with minimal effort and a reduced chance for errors. Data is utilized as it is entered; the preprocessor then decides what additional data is required to complete the model. Only this required information is requested. The preprocessor can accommodate data input for any SHABERTH compatible shaft bearing system model. The system may include ball bearings, roller bearings, and/or tapered roller bearings. SHABERTH is written in FORTRAN 77, and two machine versions are available from COSMIC. The CRAY version (LEW-14860) has a RAM requirement of 176K of 64 bit words. The IBM PC version (MFS-28818) is written for IBM PC series and compatible computers running MS-DOS, and includes a sample MS-DOS executable. For execution, the PC version requires at least 1Mb of RAM and an 80386 or 486 processor machine with an 80x87 math co-processor. The standard distribution medium for the

  15. Solar Advisor Model User Guide for Version 2.0

    Energy Technology Data Exchange (ETDEWEB)

    Gilman, P.; Blair, N.; Mehos, M.; Christensen, C.; Janzou, S.; Cameron, C.

    2008-08-01

    The Solar Advisor Model (SAM) provides a consistent framework for analyzing and comparing power system costs and performance across the range of solar technologies and markets, from photovoltaic systems for residential and commercial markets to concentrating solar power and large photovoltaic systems for utility markets. This manual describes Version 2.0 of the software, which can model photovoltaic and concentrating solar power technologies for electric applications for several markets. The current version of the Solar Advisor Model does not model solar heating and lighting technologies.

  16. U.S. Climate Divisional Dataset (Version Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data has been superseded by a newer version of the dataset. Please refer to NOAA's Climate Divisional Database for more information. The U.S. Climate Divisional...

  17. An accuracy assessment of the CALIOP/CALIPSO version 2/version 3 daytime aerosol extinction product based on a detailed multi-sensor, multi-platform case study

    Directory of Open Access Journals (Sweden)

    M. Kacenelenbogen

    2011-04-01

    Full Text Available The Cloud Aerosol LIdar with Orthogonal Polarization (CALIOP, on board the CALIPSO platform, has measured profiles of total attenuated backscatter coefficient (level 1 products since June 2006. CALIOP's level 2 products, such as the aerosol backscatter and extinction coefficient profiles, are retrieved using a complex succession of automated algorithms. The goal of this study is to help identify potential shortcomings in the CALIOP version 2 level 2 aerosol extinction product and to illustrate some of the motivation for the changes that have been introduced in the next version of CALIOP data (version 3, released in June 2010. To help illustrate the potential factors contributing to the uncertainty of the CALIOP aerosol extinction retrieval, we focus on a one-day, multi-instrument, multiplatform comparison study during the CALIPSO and Twilight Zone (CATZ validation campaign on 4 August 2007. On that day, we observe a consistency in the Aerosol Optical Depth (AOD values recorded by four different instruments (i.e. space-borne MODerate Imaging Spectroradiometer, MODIS: 0.67 and POLarization and Directionality of Earth's Reflectances, POLDER: 0.58, airborne High Spectral Resolution Lidar, HSRL: 0.52 and ground-based AErosol RObotic NETwork, AERONET: 0.48 to 0.73 while CALIOP AOD is a factor of two lower (0.32 at 532 nm. This case study illustrates the following potential sources of uncertainty in the CALIOP AOD: (i CALIOP's low signal-to-noise ratio (SNR leading to the misclassification and/or lack of aerosol layer identification, especially close to the Earth's surface; (ii the cloud contamination of CALIOP version 2 aerosol backscatter and extinction profiles; (iii potentially erroneous assumptions of the aerosol extinction-to-backscatter ratio (Sa used in CALIOP's extinction retrievals; and (iv calibration coefficient biases in the CALIOP daytime attenuated backscatter coefficient profiles. The use of version 3 CALIOP extinction

  18. Validity and Reliability of Agoraphobic Cognitions Questionnaire-Turkish Version

    Directory of Open Access Journals (Sweden)

    Ayşegül KART

    2013-11-01

    Full Text Available Validity and Reliability of Agoraphobic Cognitions Questionnaire-Turkish Version Objective: The aim of this study is to investigate the validity and reliability of Agoraphobic Cognitions Questionnaire -Turkish Version (ACQ. Method: ACQ was administered to 92 patients with agoraphobia or panic disorder with agoraphobia. BSQ Turkish version completed by translation, back-translation and pilot assessment. Reliability of ACQ was analyzed by test-retest correlation, split-half technique, Cronbach’s alpha coefficient. Construct validity was evaluated by factor analysis after the Kaiser-Meyer-Olkin (KMO and Bartlett test had been performed. Principal component analysis and varimax rotation used for factor analysis. Results: 64% of patients evaluated in the study were female and 36% were male. Age interval was between 18 and 58, mean age was 31.5±10.4. The Cronbach’s alpha coefficient was 0.91. Analysis of test-retest evaluations revealed that there were statistically significant correlations ranging between 24% and 84% concerning questionnaire components. In analysis performed by split-half method reliability coefficients of half questionnaires were found as 0.77 and 0.91. Again Spearmen-Brown coefficient was found as 0.87 by the same analysis. To assess construct validity of ACQ, factor analysis was performed and two basic factors found. These two factors explained 57.6% of the total variance. (Factor 1: 34.6%, Factor 2: 23% Conclusion: Our findings support that ACQ-Turkish version had a satisfactory level of reliability and validity

  19. Fuel behaviour calculations with version 2.0 of the code FUROM

    International Nuclear Information System (INIS)

    Kulacsy, K.

    2011-01-01

    The fuel modelling code FUROM (FUel ROd Model), suitable for calculating the normal operation condition behaviour of PWR and WWER fuels, has been developed at AEKI for several years. In 2010 the new version of the code, FUROM-2.0 was released. Calculations performed with this version and results are presented. (author)

  20. A Design Case: Developing an Enhanced Version of the Diffusion Simulation Game

    Directory of Open Access Journals (Sweden)

    Rodney Myers

    2010-01-01

    Full Text Available In this paper, we present a design case describing the creation of a new online version of the Diffusion Simulation Game (DSG. The DSG is a serious game that teaches change management strategies aligned with Rogers’ (2003 diffusion of innovations theory. The goal of the game is to promote the understanding of strategies that result in the adoption of an instructional innovation by the staff members of a fictional junior high school. The original board version of the game was created in the 1970s (Molenda and Rice, 1979 and was played as part of a course in the School of Education of a large Midwestern university. With the opening of a distance master’s program, the first online version of the game was developed in 2002 (Frick, Ludwig, Kim, & Huang, 2003. In order to overcome some of the limitations of the first online version, a new online version of the DSG was developed. This new version was rapidly prototyped first on paper and then in Flex Builder, ActionScript, PHP and MySQL. A rapid prototype approach (Tripp & Bichelmeyer, 1990 was utilized to iteratively design the user interface. In addition to describing the design process and rationale for design decisions, we also report results of play-tests and usability evaluations of seven recruited participants and how the information collected from these evaluations will help us to improve the current design.

  1. Adjusted linguistic validation and psychometric properties of the Colombian version of KIDSCREEN-52.

    Science.gov (United States)

    Jaimes-Valencia, Mary Luz; Perpiñá-Galvañ, Juana; Cabañero-Martínez, Maria José; Cabrero-García, Julio; Richart-Martínez, Miguel

    2018-01-01

    In health and clinical studies, health-related quality of life is often assessed using the well-established KIDSCREEN-52 questionnaires as well as the Vécu et Santé Perçue de l'Adolescent (VSP-A). The purpose of this study was twofold: to perform an adjusted linguistic validation of the Colombian version of the KIDSCREEN-52 and to assess its psychometric properties in children and adolescents. A total of 146 children and adolescents completed the KIDSCREEN-52, adolescents ( n = 48) additionally completed the VSP-A. Psychometric analyses focused on the internal consistency as well as the convergent and discriminant validity of the KIDSCREEN-52 Colombian version. Syntactic and semantic modifications were made to 19 items in the adapted version of the KIDSCREEN-52. Cronbach's α ranged from .74 to .89 for eight dimensions, while α Colombian version of the KIDSCREEN-52 showed acceptable reliability and validity. This study provides a cultural adaptation of the Spanish version of the KIDSCREEN-52 for Colombian children and adolescents.

  2. Validation of the Persian Version of the Problematic Internet Use Questionnaire (PIUQ.

    Directory of Open Access Journals (Sweden)

    Hadi Ranjbar

    2014-12-01

    Full Text Available The most commonly used instrument for the research and treatment of excessive internet use is Young's Internet Addiction Test (IAT. While the IAT has been translated to several languages (including Persian and has demonstrated good psychometric properties across several independent studies, there is still a room for alternative assessment instruments. This study reports a validation of the Persian version of the Problematic Internet Use Questionnaire (PIUQ.A sample (n = 296 from Kerman, Iran was administered the translated Persian version of the PIUQ as well as the Persian version of the University of California, Los Angeles (UCLA Loneliness scale, Satisfaction With Life scale, and questions related to use of technology and the internet.Analyses using confirmatory and exploratory factor analyses demonstrated that the Persian version of the PIUQ had good internal reliability and concurrent validity (with loneliness and satisfaction with life, but they also had an alternative factor structure that did not support the original factor structure.The Persian version of the PIUQ produced adequate psychometric properties (internal reliability and concurrent validity, but care should be taken in the interpretation of the factor structure.

  3. Cosmological perturbations in the projectable version of Hořava-Lifshitz gravity

    International Nuclear Information System (INIS)

    Cerioni, Alessandro; Brandenberger, Robert H.

    2011-01-01

    We consider linear perturbations about a homogeneous and isotropic cosmological background in the projectable version of Hořava-Lifshitz gravity. Starting from the action for cosmological perturbations, we identify the canonically normalized fluctuation variables. We find that - in contrast to what happens in the non-projectable version of the theory - the extra scalar cosmological perturbation mode is already dynamical at the level of linear perturbations and is either ghost-like or tachyonic depending on the value of a free parameter. This indicates a problem for the projectable version of Hořava-Lifshitz gravity

  4. Development of the unified version of COBRA/RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, J J; Ha, K S; Chung, B D; Lee, W J; Sim, S K [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    The COBRA/RELAP5 code, an integrated version of the COBRA-TF and RELAP5/MOD3 codes, has been developed for the realistic simulations of complicated, multi-dimensional, two-phase, thermal-hydraulic system transients in light water reactors. Recently, KAERI developed an unified version of the COBRA/RELAP5 code, which can run in serial mode on both workstations and personal computers. This paper provides the brief overview of the code integration scheme, the recent code modifications, the developmental assessments, and the future development plan. 13 refs., 5 figs., 2 tabs. (Author)

  5. Development of the unified version of COBRA/RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, J. J.; Ha, K. S.; Chung, B. D.; Lee, W. J.; Sim, S. K. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    The COBRA/RELAP5 code, an integrated version of the COBRA-TF and RELAP5/MOD3 codes, has been developed for the realistic simulations of complicated, multi-dimensional, two-phase, thermal-hydraulic system transients in light water reactors. Recently, KAERI developed an unified version of the COBRA/RELAP5 code, which can run in serial mode on both workstations and personal computers. This paper provides the brief overview of the code integration scheme, the recent code modifications, the developmental assessments, and the future development plan. 13 refs., 5 figs., 2 tabs. (Author)

  6. SAGE Version 7.0 Algorithm: Application to SAGE II

    Science.gov (United States)

    Damadeo, R. P; Zawodny, J. M.; Thomason, L. W.; Iyer, N.

    2013-01-01

    This paper details the Stratospheric Aerosol and Gas Experiments (SAGE) version 7.0 algorithm and how it is applied to SAGE II. Changes made between the previous (v6.2) and current (v7.0) versions are described and their impacts on the data products explained for both coincident event comparisons and time-series analysis. Users of the data will notice a general improvement in all of the SAGE II data products, which are now in better agreement with more modern data sets (e.g. SAGE III) and more robust for use with trend studies.

  7. Mission Data System Java Edition Version 7

    Science.gov (United States)

    Reinholtz, William K.; Wagner, David A.

    2013-01-01

    The Mission Data System framework defines closed-loop control system abstractions from State Analysis including interfaces for state variables, goals, estimators, and controllers that can be adapted to implement a goal-oriented control system. The framework further provides an execution environment that includes a goal scheduler, execution engine, and fault monitor that support the expression of goal network activity plans. Using these frameworks, adapters can build a goal-oriented control system where activity coordination is verified before execution begins (plan time), and continually during execution. Plan failures including violations of safety constraints expressed in the plan can be handled through automatic re-planning. This version optimizes a number of key interfaces and features to minimize dependencies, performance overhead, and improve reliability. Fault diagnosis and real-time projection capabilities are incorporated. This version enhances earlier versions primarily through optimizations and quality improvements that raise the technology readiness level. Goals explicitly constrain system states over explicit time intervals to eliminate ambiguity about intent, as compared to command-oriented control that only implies persistent intent until another command is sent. A goal network scheduling and verification process ensures that all goals in the plan are achievable before starting execution. Goal failures at runtime can be detected (including predicted failures) and handled by adapted response logic. Responses can include plan repairs (try an alternate tactic to achieve the same goal), goal shedding, ignoring the fault, cancelling the plan, or safing the system.

  8. Overview of MPLNET Version 3 Cloud Detection

    Science.gov (United States)

    Lewis, Jasper R.; Campbell, James; Welton, Ellsworth J.; Stewart, Sebastian A.; Haftings, Phillip

    2016-01-01

    The National Aeronautics and Space Administration Micro Pulse Lidar Network, version 3, cloud detection algorithm is described and differences relative to the previous version are highlighted. Clouds are identified from normalized level 1 signal profiles using two complementary methods. The first method considers vertical signal derivatives for detecting low-level clouds. The second method, which detects high-level clouds like cirrus, is based on signal uncertainties necessitated by the relatively low signal-to-noise ratio exhibited in the upper troposphere by eye-safe network instruments, especially during daytime. Furthermore, a multitemporal averaging scheme is used to improve cloud detection under conditions of a weak signal-to-noise ratio. Diurnal and seasonal cycles of cloud occurrence frequency based on one year of measurements at the Goddard Space Flight Center (Greenbelt, Maryland) site are compared for the new and previous versions. The largest differences, and perceived improvement, in detection occurs for high clouds (above 5 km, above MSL), which increase in occurrence by over 5%. There is also an increase in the detection of multilayered cloud profiles from 9% to 19%. Macrophysical properties and estimates of cloud optical depth are presented for a transparent cirrus dataset. However, the limit to which the cirrus cloud optical depth could be reliably estimated occurs between 0.5 and 0.8. A comparison using collocated CALIPSO measurements at the Goddard Space Flight Center and Singapore Micro Pulse Lidar Network (MPLNET) sites indicates improvements in cloud occurrence frequencies and layer heights.

  9. External cephalic version for breech presentation at term

    International Nuclear Information System (INIS)

    Rauf, B.; Hassan, L.

    2007-01-01

    To assess the success rate of External Cephalic Version (ECV) at term and its effects on measures of pregnancy outcome. A total of 40 patients were offered ECV over a period of fourteen months. All singleton breech presentations with an otherwise normal antenatal course between 36-41 weeks of gestation were included in the study. Exclusion criteria included contraindications to ECV i.e. multiple pregnancy, oligohydramnios, growth retardation, antepartum hemorrhage, rupture of membranes toxemias of pregnancy, non-reassuring fetal monitoring pattern, previous uterine scar, bad obstetric history, any contraindication to vaginal delivery, labour and patient wishes after thorough counseling. Overall success rate of the procedure and its effect on maternal and fetal outcome was determined. Significance of results was determined using Chi-square test. A total of 40 patients were recruited for the trial. Overall success rate was 67.5% with only 30% being primi-gravida (p<0.05). Multi-gravida showed higher success rate of 80%. Following successful ECV, spontaneous vaginal delivery was attained in 77.7% (n=21), while caesarean section was performed due to various indications in about 6 cases (p<0.05). Following failed version, 61.5% (n=8) had elective C/S and only 5 delivered vaginally. Route of delivery did not affect the perinatal outcome except for congenital abnormalities. Following successful ECV, there was only one stillbirth. Overall live births associated with successful version was 96.2% (p<0.05), while in failed version, there were no fetal deaths. ECV at term appears to be a useful procedure to reduce the number and associated complications of term breech presentation. It is safe for the mother and the fetus and helps to avoid a significant number of caesarean sections. (author)

  10. Testing the psychometric properties of a Chinese version of the level of expressed emotion scale.

    Science.gov (United States)

    Chien, Wai Tong; Chan, Zenobia Chung-Yee; Chan, Sally Wai-Chi

    2014-01-01

    This study tested the psychometric properties of a Chinese version of the level of expressed emotion scale in Hong Kong Chinese patients with severe mental illness and their family caregivers. First, the semantic equivalence with the original English version and test-retest reliability at 2-week interval of the Chinese version was examined. After that, the reproducibility, construct validity, and internal consistency of the Chinese version were tested. The Chinese version indicated good semantic equivalence with the English version (kappa values = 0.76-0.95 and ICC = 0.81-0.92), test-retest reliability (r = 0.89-0.95, P Chinese version had substantial loadings on one of the four factors identified (intrusiveness/hostility, attitude towards patient, tolerance, and emotional involvement), accounting for 71.8% of the total variance of expressed emotion. In confirmatory factor analysis, the identified four-factor model showed the best fit based on all fit indices (χ (2)/df = 1.93, P = 0.75; AGFI = 0.96; TLI = 1.02; RMSEA = 0.031; WRMR = 0.78) to the collected data. The four-factor Chinese version also indicated a good concurrent validity with significant correlations with family functioning (r = -0.54) and family burden (r = 0.49) and a satisfactory reproducibility over six months (intraclass correlation coefficient of 0.90). The mean scores of the overall and subscale of the Chinese version in patients with unipolar disorder were higher than in other illness groups (schizophrenia, psychotic disorders, and bipolar disorder; P Chinese version demonstrates sound psychometric properties to measure families' expressed emotion in Chinese patients with severe mental illness, which are found varied across countries.

  11. Reflections on the nature of genius: on the 300th anniversary of Mikhail Lomonosov (1711-1765)

    CERN Document Server

    Shiltsev, V

    2012-01-01

    This presentation goes beyond celebratory narration of the life and scientific achievements of Russia's first modern scientist Mikhail Vasilievich Lomonosov (1711-1765). Coming from the notion of complexity of sciences, we introduce "a genius formula" G=TBD for semi-qualitative evaluation of a person's impact on the society, distinguish two type of geniuses, give several examples and draw general conclusions. The work largely follows presentation at the Fermilab Colloquium in November of 2011.

  12. Salvage Stories, Preserving Narratives, and Museum Ships

    OpenAIRE

    Andrew Sawyer

    2013-01-01

    Preserved ships and other vessels are associated with a historiography, in Europe at least, which is still marked by parochialism, antiquarianism, and celebratory narrative. Many evidence difficult histories, and they are also extremely expensive to preserve. Yet, they are clearly valued, as nations in Europe invest heavily in them. This survey examines a range of European examples as sites of cultural, political and national identity. An analytical framework foregrounding the role of narrati...

  13. Reflections on the nature of genius: on the 300th anniversary of Mikhail Lomonosov (1711-1765)

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, V [Fermilab (United States)

    2012-07-01

    This presentation goes beyond celebratory narration of the life and scientific achievements of Russia's first modern scientist Mikhail Vasilievich Lomonosov (1711-1765). Coming from the notion of complexity of sciences, we introduce 'a genius formula' G=TBD for semi-qualitative evaluation of a person's impact on the society, distinguish two type of geniuses, give several examples and draw general conclusions. The work largely follows presentation at the Fermilab Colloquium in November of 2011. (author)

  14. Hong Kong faces uncertain future as oil supply centre

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Paul [Pearl Oil Ltd. (Hong Kong)

    1997-09-01

    Hong Kong`s first day under Chinese rule, 1 July 1997, was not exactly auspicious. A celebratory parade organized by the Chinese was washed out by torrential rain, and the grand finale of a firework display, described as `a bold statement..... embodying confidence in the future of Hong Kong` fizzled out when one of the firework barges caught fire. The omens are not necessarily good for the territory`s oil industry either. (author)

  15. Validity and Reliability of Farsi Version of Youth Sport Environment Questionnaire

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Eshghi

    2015-01-01

    Full Text Available The Youth Sport Environment Questionnaire (YSEQ had been developed from Group Environment Questionnaire, a well-known measure of team cohesion. The aim of this study was to adapt and examine the reliability and validity of the Farsi version of the YSEQ. This version was completed by 455 athletes aged 13–17 years. Results of confirmatory factor analysis indicated that two-factor solution showed a good fit to the data. The results also revealed that the Farsi YSEQ showed high internal consistency, test-retest reliability, and good concurrent validity. This study indicated that the Farsi version of the YSEQ is a valid and reliable measure to assess team cohesion in sport setting.

  16. Fear for external cephalic version and depression : Predictors of successful external cephalic version for breech presentation at term?

    NARCIS (Netherlands)

    Ciliacus, Emily; van der Zalm, Marieke; Truijens, Sophie E.; Hasaart, Tom H.; Pop, Victor J.; Kuppens, Simone M.

    2014-01-01

    Background Objective was to determine whether fear for external cephalic version (ECV) and depression are associated with the success rate of ECV in women with a breech presentation at term. Methods Prospective study conducted in the Catharina Hospital Eindhoven between October 2007 and May 2012.

  17. New version of the web based CERN Phonebook

    CERN Multimedia

    GS Department

    2011-01-01

    A new version of CERN’s web-based phonebook will be deployed during the weekend of 17/18 December 2011. The most important new feature will be the possibility to see the CERN identity card photo of every person listed in the phonebook who has a registered photo.   The photo will be available on each person's details page and will be visible to all employed and associated members of the personnel who have the appropriate authentication (i.e. those who log in using their AIS login). More information about other new features of the release will be available from 19 December 2011 from the webpage detailing the version history of the CERN phonebook.

  18. ANLECIS-1: Version of ANLECIS Program for Calculations with the Asymetric Rotational Model

    International Nuclear Information System (INIS)

    Lopez Mendez, R.; Garcia Moruarte, F.

    1986-01-01

    A new modified version of the ANLECIS Code is reported. This version allows to fit simultaneously the cross section of the direct process by the asymetric rotational model, and the cross section of the compound nucleus process by the Hauser-Feshbach formalism with the modern statistical corrections. The calculations based in this version show a dependence of the compound nucleus cross section with respect to the asymetric parameter γ. (author). 19 refs

  19. TOUGH2 User's Guide Version 2

    International Nuclear Information System (INIS)

    Pruess, K.; Oldenburg, C.M.; Moridis, G.J.

    1999-01-01

    TOUGH2 is a numerical simulator for nonisothermal flows of multicomponent, multiphase fluids in one, two, and three-dimensional porous and fractured media. The chief applications for which TOUGH2 is designed are in geothermal reservoir engineering, nuclear waste disposal, environmental assessment and remediation, and unsaturated and saturated zone hydrology. TOUGH2 was first released to the public in 1991; the 1991 code was updated in 1994 when a set of preconditioned conjugate gradient solvers was added to allow a more efficient solution of large problems. The current Version 2.0 features several new fluid property modules and offers enhanced process modeling capabilities, such as coupled reservoir-wellbore flow, precipitation and dissolution effects, and multiphase diffusion. Numerous improvements in previously released modules have been made and new user features have been added, such as enhanced linear equation solvers, and writing of graphics files. The T2VOC module for three-phase flows of water, air and a volatile organic chemical (VOC), and the T2DM module for hydrodynamic dispersion in 2-D flow systems have been integrated into the overall structure of the code and are included in the Version 2.0 package. Data inputs are upwardly compatible with the previous version. Coding changes were generally kept to a minimum, and were only made as needed to achieve the additional functionalities desired. TOUGH2 is written in standard FORTRAN77 and can be run on any platform, such as workstations, PCs, Macintosh, mainframe and supercomputers, for which appropriate FORTRAN compilers are available. This report is a self-contained guide to application of TOUGH2 to subsurface flow problems. It gives a technical description of the TOUGH2 code, including a discussion of the physical processes modeled, and the mathematical and numerical methods used. Illustrative sample problems are presented along with detailed instructions for preparing input data

  20. Ultrasonographic evaluation of myometrial thickness and prediction of a successful external cephalic version.

    Science.gov (United States)

    Buhimschi, Catalin S; Buhimschi, Irina A; Wehrum, Mark J; Molaskey-Jones, Sherry; Sfakianaki, Anna K; Pettker, Christian M; Thung, Stephen; Campbell, Katherine H; Dulay, Antonette T; Funai, Edmund F; Bahtiyar, Mert O

    2011-10-01

    To test the hypothesis that myometrial thickness predicts the success of external cephalic version. Abdominal ultrasonographic scans were performed in 114 consecutive pregnant women with breech singletons before an external cephalic version maneuver. Myometrial thickness was measured by a standardized protocol at three sites: the lower segment, midanterior wall, and the fundal uterine wall. Independent variables analyzed in conjunction with myometrial thickness were: maternal age, parity, body mass index, abdominal wall thickness, estimated fetal weight, amniotic fluid index, placental thickness and location, fetal spine position, breech type, and delivery outcomes such as final mode of delivery and birth weight. Successful version was associated with a thicker ultrasonographic fundal myometrium (unsuccessful: 6.7 [5.5-8.4] compared with successful: 7.4 [6.6-9.7] mm, P=.037). Multivariate regression analysis showed that increased fundal myometrial thickness, high amniotic fluid index, and nonfrank breech presentation were the strongest independent predictors of external cephalic version success (Pexternal cephalic versions (fundal myometrial thickness: odds ratio [OR] 2.4, 95% confidence interval [CI] 1.1-5.2, P=.029; amniotic fluid index: OR 2.8, 95% CI 1.3-6.0, P=.008). Combining the two variables resulted in an absolute risk reduction for a failed version of 27.6% (95% CI 7.1-48.1) and a number needed to treat of four (95% CI 2.1-14.2). Fundal myometrial thickness and amniotic fluid index contribute to success of external cephalic version and their evaluation can be easily incorporated in algorithms before the procedure. III.

  1. Recent development of BOA version 3

    International Nuclear Information System (INIS)

    Deshon, J.; Hussey, D.; Westacott, J.; Young, M.; Secker, J.; Epperson, K.; McGurk, J.; Henshaw, J.

    2010-01-01

    BOA is the EPRI code developed to help understand material transport issues in PWR systems. In particular, BOA was developed to investigate the problem of crud induced power shifts (CIPS) or axial offset anomalies (AOA) that are related to crud accumulation on fuel clad and the subsequent uptake of boron within this crud. Over the last few years significant developments of BOA have taken place; these include new models for release and deposition of soluble and particulate material as well as new models for boron capture in the crud. The new version of BOA (version 3), as well as predicting the extent of AOA a plant might expect during a cycle, also predicts soluble and particulate Ni/Fe levels in the coolant, end of cycle Ni shut-down releases and the relative amounts of Ni/Fe within the fuel crud. The model is being validated against plant data and this paper briefly discusses the recent developments, the fundamental scientific basis for these changes and some of the validation studies. (author)

  2. New Web Server - the Java Version of Tempest - Produced

    Science.gov (United States)

    York, David W.; Ponyik, Joseph G.

    2000-01-01

    A new software design and development effort has produced a Java (Sun Microsystems, Inc.) version of the award-winning Tempest software (refs. 1 and 2). In 1999, the Embedded Web Technology (EWT) team received a prestigious R&D 100 Award for Tempest, Java Version. In this article, "Tempest" will refer to the Java version of Tempest, a World Wide Web server for desktop or embedded systems. Tempest was designed at the NASA Glenn Research Center at Lewis Field to run on any platform for which a Java Virtual Machine (JVM, Sun Microsystems, Inc.) exists. The JVM acts as a translator between the native code of the platform and the byte code of Tempest, which is compiled in Java. These byte code files are Java executables with a ".class" extension. Multiple byte code files can be zipped together as a "*.jar" file for more efficient transmission over the Internet. Today's popular browsers, such as Netscape (Netscape Communications Corporation) and Internet Explorer (Microsoft Corporation) have built-in Virtual Machines to display Java applets.

  3. Trigonometric version of quantum–classical duality in integrable systems

    Directory of Open Access Journals (Sweden)

    M. Beketov

    2016-02-01

    Full Text Available We extend the quantum–classical duality to the trigonometric (hyperbolic case. The duality establishes an explicit relationship between the classical N-body trigonometric Ruijsenaars–Schneider model and the inhomogeneous twisted XXZ spin chain on N sites. Similarly to the rational version, the spin chain data fixes a certain Lagrangian submanifold in the phase space of the classical integrable system. The inhomogeneity parameters are equal to the coordinates of particles while the velocities of classical particles are proportional to the eigenvalues of the spin chain Hamiltonians (residues of the properly normalized transfer matrix. In the rational version of the duality, the action variables of the Ruijsenaars–Schneider model are equal to the twist parameters with some multiplicities defined by quantum (occupation numbers. In contrast to the rational version, in the trigonometric case there is a splitting of the spectrum of action variables (eigenvalues of the classical Lax matrix. The limit corresponding to the classical Calogero–Sutherland system and quantum trigonometric Gaudin model is also described as well as the XX limit to free fermions.

  4. Trigonometric version of quantum–classical duality in integrable systems

    Energy Technology Data Exchange (ETDEWEB)

    Beketov, M., E-mail: beketov@phystech.edu [MIPT, Inststitutskii per. 9, 141700, Dolgoprudny, Moscow region (Russian Federation); Liashyk, A., E-mail: a.liashyk@gmail.com [National Research University Higher School of Economics, Myasnitskaya str. 20, 101000, Moscow (Russian Federation); BITP, Metrolohichna str. 14-b, 03680, Kiev (Ukraine); Zabrodin, A., E-mail: zabrodin@itep.ru [National Research University Higher School of Economics, Myasnitskaya str. 20, 101000, Moscow (Russian Federation); Institute of Biochemical Physics, Kosygina str. 4, 119991, Moscow (Russian Federation); ITEP, Bolshaya Cheremushkinskaya str. 25, 117218, Moscow (Russian Federation); Zotov, A., E-mail: zotov@mi.ras.ru [Steklov Mathematical Institute, RAS, Gubkina str. 8, 119991, Moscow (Russian Federation); ITEP, Bolshaya Cheremushkinskaya str. 25, 117218, Moscow (Russian Federation); MIPT, Inststitutskii per. 9, 141700, Dolgoprudny, Moscow region (Russian Federation)

    2016-02-15

    We extend the quantum–classical duality to the trigonometric (hyperbolic) case. The duality establishes an explicit relationship between the classical N-body trigonometric Ruijsenaars–Schneider model and the inhomogeneous twisted XXZ spin chain on N sites. Similarly to the rational version, the spin chain data fixes a certain Lagrangian submanifold in the phase space of the classical integrable system. The inhomogeneity parameters are equal to the coordinates of particles while the velocities of classical particles are proportional to the eigenvalues of the spin chain Hamiltonians (residues of the properly normalized transfer matrix). In the rational version of the duality, the action variables of the Ruijsenaars–Schneider model are equal to the twist parameters with some multiplicities defined by quantum (occupation) numbers. In contrast to the rational version, in the trigonometric case there is a splitting of the spectrum of action variables (eigenvalues of the classical Lax matrix). The limit corresponding to the classical Calogero–Sutherland system and quantum trigonometric Gaudin model is also described as well as the XX limit to free fermions.

  5. A streamlined artificial variable free version of simplex method.

    Directory of Open Access Journals (Sweden)

    Syed Inayatullah

    Full Text Available This paper proposes a streamlined form of simplex method which provides some great benefits over traditional simplex method. For instance, it does not need any kind of artificial variables or artificial constraints; it could start with any feasible or infeasible basis of an LP. This method follows the same pivoting sequence as of simplex phase 1 without showing any explicit description of artificial variables which also makes it space efficient. Later in this paper, a dual version of the new method has also been presented which provides a way to easily implement the phase 1 of traditional dual simplex method. For a problem having an initial basis which is both primal and dual infeasible, our methods provide full freedom to the user, that whether to start with primal artificial free version or dual artificial free version without making any reformulation to the LP structure. Last but not the least, it provides a teaching aid for the teachers who want to teach feasibility achievement as a separate topic before teaching optimality achievement.

  6. A streamlined artificial variable free version of simplex method.

    Science.gov (United States)

    Inayatullah, Syed; Touheed, Nasir; Imtiaz, Muhammad

    2015-01-01

    This paper proposes a streamlined form of simplex method which provides some great benefits over traditional simplex method. For instance, it does not need any kind of artificial variables or artificial constraints; it could start with any feasible or infeasible basis of an LP. This method follows the same pivoting sequence as of simplex phase 1 without showing any explicit description of artificial variables which also makes it space efficient. Later in this paper, a dual version of the new method has also been presented which provides a way to easily implement the phase 1 of traditional dual simplex method. For a problem having an initial basis which is both primal and dual infeasible, our methods provide full freedom to the user, that whether to start with primal artificial free version or dual artificial free version without making any reformulation to the LP structure. Last but not the least, it provides a teaching aid for the teachers who want to teach feasibility achievement as a separate topic before teaching optimality achievement.

  7. The relationship of glenoid and humeral version with supraspinatus tendon tears

    Energy Technology Data Exchange (ETDEWEB)

    Tokgoz, Nil; Kadioglu Voyvoda, Nuray; Gultekin, Serap; Tali, E.T. [Gazi University School of Medicine, Department of Radiology, Ankara (Turkey); Kanatli, Ulunay; Bolukbasi, Selcuk [Gazi University School of Medicine, Department of Orthopaedic Surgery, Ankara (Turkey)

    2007-06-15

    The aim of this study was to investigate the relationship of glenohumeral anatomic measurements on MR imaging with supraspinatus tendon tears. The study was approved by the institutional review board and informed consent was obtained from each subject. Forty-two patients (mean age 55.5 years; age range 40-73 years) with supraspinatus tendon tears and 50 asymptomatic shoulders of 32 controls (mean age 43 years; age range 17-69 years) without rotator cuff tears were included. The acromio-glenoid and supraspinatus-glenoid angles were measured on coronal images, the glenoid and humeral head version as well as the bicipital-humeral distance on axial images. Significant differences were found between the patients and controls for both glenoid version and bicipital-humeral distance, which are considered to influence the distribution of forces placed on the cuff (p < 0.05). The patients had a decreased glenoid version by an average of 2.3 (-7.1 {+-} 7.8 vs. -4.8 {+-} 5.6 ), and a decreased bicipital-humeral distance by an average of 2.7 mm (12.1 {+-} 3.7 mm vs. 14.8 {+-} 4.1 mm). No significant differences were found between these groups for humeral head version and the acromio-glenoid and supraspinatus-glenoid angles, which might contribute to extrinsic impingement by narrowing the supraspinatus tendon outlet. Differences in glenoid and humeral version may be responsible for RC tears by changing the orientation of the rotator cuff and thus increasing shearing stress. (orig.)

  8. Psychometric properties of the Finnish version of the Women's Health Questionnaire.

    Science.gov (United States)

    Katainen, Riina E; Engblom, Janne R; Vahlberg, Tero J; Polo-Kantola, Päivi

    2017-08-01

    The Women's Health Questionnaire (WHQ) is a validated and commonly used instrument for measuring climacteric-related symptoms. A revised version was previously developed. However, validation in a Finnish population is lacking. As it is important to use qualified instruments, we performed a validation study of the WHQ in a Finnish population. In all, 3,421 women, aged 41 to 54 years, formed the study population. In the original 36-item WHQ, the items were rated on a 1 to 4 scale and on a binary scale (0-1). The scaling of the revised 23-item WHQ was 0 to 100. We evaluated the psychometric properties (internal consistency, correlations between the symptom domains, factor structure, and sampling adequacy) in all three versions. For the 1 to 4 scale and on the revised version of the WHQ, the internal consistency was acceptable (the Cronbach's α coefficients >0.70) for most of the domains. On the binary scale, the majority of the coefficient values were below the acceptable level. The original symptom domains, especially those on the revised version, were recognizable from the factors in the exploratory factor analysis, but there were some limitations. The Kaiser-Meyer-Olkin values were high. The WHQ is a valid instrument for measuring climacteric-related symptoms in Finnish middle-aged women. The psychometric properties of the revised 23-item WHQ were as good or even better than those of the original 36-item WHQ. Thus, we encourage use of the revised version.

  9. The relationship of glenoid and humeral version with supraspinatus tendon tears

    International Nuclear Information System (INIS)

    Tokgoz, Nil; Kadioglu Voyvoda, Nuray; Gultekin, Serap; Tali, E.T.; Kanatli, Ulunay; Bolukbasi, Selcuk

    2007-01-01

    The aim of this study was to investigate the relationship of glenohumeral anatomic measurements on MR imaging with supraspinatus tendon tears. The study was approved by the institutional review board and informed consent was obtained from each subject. Forty-two patients (mean age 55.5 years; age range 40-73 years) with supraspinatus tendon tears and 50 asymptomatic shoulders of 32 controls (mean age 43 years; age range 17-69 years) without rotator cuff tears were included. The acromio-glenoid and supraspinatus-glenoid angles were measured on coronal images, the glenoid and humeral head version as well as the bicipital-humeral distance on axial images. Significant differences were found between the patients and controls for both glenoid version and bicipital-humeral distance, which are considered to influence the distribution of forces placed on the cuff (p < 0.05). The patients had a decreased glenoid version by an average of 2.3 (-7.1 ± 7.8 vs. -4.8 ± 5.6 ), and a decreased bicipital-humeral distance by an average of 2.7 mm (12.1 ± 3.7 mm vs. 14.8 ± 4.1 mm). No significant differences were found between these groups for humeral head version and the acromio-glenoid and supraspinatus-glenoid angles, which might contribute to extrinsic impingement by narrowing the supraspinatus tendon outlet. Differences in glenoid and humeral version may be responsible for RC tears by changing the orientation of the rotator cuff and thus increasing shearing stress. (orig.)

  10. Anthropogenic Biomes of the World, Version 2: 1700

    Data.gov (United States)

    National Aeronautics and Space Administration — The Anthropogenic Biomes of the World, Version 2: 1700 data set describes anthropogenic transformations within the terrestrial biosphere caused by sustained direct...

  11. Anthropogenic Biomes of the World, Version 2: 1900

    Data.gov (United States)

    National Aeronautics and Space Administration — The Anthropogenic Biomes of the World, Version 2: 1900 data set describes anthropogenic transformations within the terrestrial biosphere caused by sustained direct...

  12. Anthropogenic Biomes of the World, Version 2: 1800

    Data.gov (United States)

    National Aeronautics and Space Administration — The Anthropogenic Biomes of the World, Version 2: 1800 data set describes anthropogenic transformations within the terrestrial biosphere caused by sustained direct...

  13. Anthropogenic Biomes of the World, Version 2: 2000

    Data.gov (United States)

    National Aeronautics and Space Administration — The Anthropogenic Biomes of the World, Version 2: 2000 data set describes anthropogenic transformations within the terrestrial biosphere caused by sustained direct...

  14. Behavioural Regulation in Exercise Questionnaire in people with schizophrenia: construct validity of the Portuguese versions.

    Science.gov (United States)

    Costa, Raquel; Probst, Michel; Bastos, Tânia; Vilhena, Estela; Seabra, André; Corredeira, Rui

    2017-06-22

    People with schizophrenia have low physical activity levels that can be explained by the restriction in motivation. The Behavioural Regulation in Exercise Questionnaire-2 is a 19-item scale commonly used to assess five different motivational subtypes for physical activity. However, there are limited psychometric analyses of this version in the schizophrenia context. Moreover, there is a lack of information related to the psychometric properties of version 3 of this questionnaire, with 24 items and six different motivational subtypes. The aim of this study was to examine the construct validity of both Portuguese versions in people with schizophrenia. A total of 118 persons with schizophrenia were included (30 women). Cronbach's alpha was used for internal consistency, Pearson's correlation for the retained motivation-types, confirmatory factor analysis for the structural validity of version 2 and exploratory factor analysis for the factor structure of version 3. Analyses of version 2 provided an adequate fit index for the structure of the five factors. Exploratory analyses suggested retaining 2 factors of version 3. The results of this study suggest that version 3 was an appropriate measure to assess controlled and autonomous motivation for physical activity in people with schizophrenia and support its use in clinical practice and research. Implications for Rehabilitation This study supports the need to identify the reasons why people with schizophrenia practice physical activity. For that purpose, it is important to use valid and cost-effective instruments. The Portuguese version of BREQ-2 confirmed a 5-factor model and showed adequate fit for the application in people with schizophrenia. However, the incremental indices values were lower than expected. The Portuguese version of BREQ-3 showed acceptable psychometric properties to assess controlled and autonomous motivation for physical activity in people with schizophrenia.

  15. Testing the Psychometric Properties of a Chinese Version of the Level of Expressed Emotion Scale

    Directory of Open Access Journals (Sweden)

    Wai Tong Chien

    2014-01-01

    Full Text Available This study tested the psychometric properties of a Chinese version of the level of expressed emotion scale in Hong Kong Chinese patients with severe mental illness and their family caregivers. First, the semantic equivalence with the original English version and test-retest reliability at 2-week interval of the Chinese version was examined. After that, the reproducibility, construct validity, and internal consistency of the Chinese version were tested. The Chinese version indicated good semantic equivalence with the English version (kappa values = 0.76–0.95 and ICC = 0.81–0.92, test-retest reliability (r = 0.89–0.95, P<0.01, and internal consistency (Cronbach’s α = 0.86–0.92. Among 262 patients with severe mental illness and their caregivers, the 50-item Chinese version had substantial loadings on one of the four factors identified (intrusiveness/hostility, attitude towards patient, tolerance, and emotional involvement, accounting for 71.8% of the total variance of expressed emotion. In confirmatory factor analysis, the identified four-factor model showed the best fit based on all fit indices (χ2/df = 1.93, P=0.75; AGFI = 0.96; TLI = 1.02; RMSEA = 0.031; WRMR = 0.78 to the collected data. The four-factor Chinese version also indicated a good concurrent validity with significant correlations with family functioning (r = −0.54 and family burden (r = 0.49 and a satisfactory reproducibility over six months (intraclass correlation coefficient of 0.90. The mean scores of the overall and subscale of the Chinese version in patients with unipolar disorder were higher than in other illness groups (schizophrenia, psychotic disorders, and bipolar disorder; P<0.01. The Chinese version demonstrates sound psychometric properties to measure families’ expressed emotion in Chinese patients with severe mental illness, which are found varied across countries.

  16. On a quantum version of conservation laws for derivative nonlinear Schrodinger equation

    International Nuclear Information System (INIS)

    Sen, S.; Chowdhury, A.R.

    1988-01-01

    The authors derived the quantum mechanical versions of infinite number of conservation laws associated with Derivative Nonlinear Schrodinger equation with the help of a methodology used in string theory. The renormalised version of the conserved quantities are obtained with explicit forms of the counter terms

  17. A hybrid version of swan for fast and efficient practical wave modelling

    NARCIS (Netherlands)

    M. Genseberger (Menno); J. Donners

    2016-01-01

    htmlabstractIn the Netherlands, for coastal and inland water applications, wave modelling with SWAN has become a main ingredient. However, computational times are relatively high. Therefore we investigated the parallel efficiency of the current MPI and OpenMP versions of SWAN. The MPI version is

  18. Stravinsky: Symphony in E flat, Op. 1. Firebird-Suite (1919 version / Jonathan Swain

    Index Scriptorium Estoniae

    Swain, Jonathan

    1994-01-01

    Uuest heliplaadist "Stravinsky: Symphony in E flat, Op. 1. Firebird-Suite (1919 version). Royal Philharmonic Orchestra / Dalia Atlas; Symphony - comparative versions: SNO, Gibson. SRO, Järvi (2/94)(CHAN) CHAN 9236

  19. Conversion tool for the LWR transient analysis code RELAP5 from the CDC version to the FACOM version

    International Nuclear Information System (INIS)

    Shinozawa, Naohisa; Fujisaki, Masahide; Makino, Mitsuhiro; Kondou, Kazuya; Ishiguro, Misako

    1987-01-01

    The LWR transient analysis code RELAP5 has been developed on the CDC-CYBER 176 at Idaho National Engineering Laboratory (INEL), the RELAP5 code has been often updated in order to extend the analyzing model and correct the errors. At Japan Atomic Energy Research Institute the code has been converted from the CDC version to the FACOM version and the converted code has been used. The conversion is the task which consumes a lot of time, because the code is large and there is the difference between CDC's machines and FACOM's ones. In order to convert the RELAP5 code automatically, the software tool has been developed. By using this tools the efficiency for converting the RELAP5 code has been improved. Productivity of the conversion is increased about 2.0 to 2.6 times by the tools in comparison with in manual. The procedure of conversion by using the tools and the option parameters of each tool are described. (author)

  20. PVWatts Version 5 Manual

    Energy Technology Data Exchange (ETDEWEB)

    Dobos, A. P.

    2014-09-01

    The NREL PVWatts calculator is a web application developed by the National Renewable Energy Laboratory (NREL) that estimates the electricity production of a grid-connected photovoltaic system based on a few simple inputs. PVWatts combines a number of sub-models to predict overall system performance, and makes includes several built-in parameters that are hidden from the user. This technical reference describes the sub-models, documents assumptions and hidden parameters, and explains the sequence of calculations that yield the final system performance estimate. This reference is applicable to the significantly revised version of PVWatts released by NREL in 2014.

  1. The National Energy Audit (NEAT) Engineering Manual (Version 6)

    Energy Technology Data Exchange (ETDEWEB)

    Gettings, M.B.

    2001-04-20

    Government-funded weatherization assistance programs resulted from increased oil prices caused by the 1973 oil embargo. These programs were instituted to reduce US consumption of oil and help low-income families afford the increasing cost of heating their homes. In the summer of 1988, Oak Ridge National Laboratory (ORNL) began providing technical support to the Department of Energy (DOE) Weatherization Assistance Program (WAP). A preliminary study found no suitable means of cost-effectively selecting energy efficiency improvements (measures) for single-family homes that incorporated all the factors seen as beneficial in improving cost-effectiveness and usability. In mid-1989, ORNL was authorized to begin development of a computer-based measure selection technique. In November of 1992 a draft version of the program was made available to all WAP state directors for testing. The first production release, Version 4.3, was made available in october of 1993. The Department of Energy's Weatherization Assistance Program has continued funding improvements to the program increasing its user-friendliness and applicability. initial publication of this engineering manual coincides with availability of Version 6.1, November 1997, though algorithms described generally apply to all prior versions. Periodic updates of specific sections in the manual will permit maintaining a relevant document. This Engineering Manual delineates the assumptions used by NEAT in arriving at the measure recommendations based on the user's input of the building characteristics. Details of the actual data entry are available in the NEAT User's Manual (ORNL/Sub/91-SK078/1) and will not be discussed in this manual.

  2. Validation of the Spanish Addiction Severity Index Multimedia Version (S-ASI-MV).

    Science.gov (United States)

    Butler, Stephen F; Redondo, José Pedro; Fernandez, Kathrine C; Villapiano, Albert

    2009-01-01

    This study aimed to develop and test the reliability and validity of a Spanish adaptation of the ASI-MV, a computer administered version of the Addiction Severity Index, called the S-ASI-MV. Participants were 185 native Spanish-speaking adult clients from substance abuse treatment facilities serving Spanish-speaking clients in Florida, New Mexico, California, and Puerto Rico. Participants were administered the S-ASI-MV as well as Spanish versions of the general health subscale of the SF-36, the work and family unit subscales of the Social Adjustment Scale Self-Report, the Michigan Alcohol Screening Test, the alcohol and drug subscales of the Personality Assessment Inventory, and the Hopkins Symptom Checklist-90. Three-to-five-day test-retest reliability was examined along with criterion validity, convergent/discriminant validity, and factorial validity. Measurement invariance between the English and Spanish versions of the ASI-MV was also examined. The S-ASI-MV demonstrated good test-retest reliability (ICCs for composite scores between .59 and .93), criterion validity (rs for composite scores between .66 and .87), and convergent/discriminant validity. Factorial validity and measurement invariance were demonstrated. These results compared favorably with those reported for the original interviewer version of the ASI and the English version of the ASI-MV.

  3. Program package for multicanonical simulations of U(1) lattice gauge theory-Second version

    Science.gov (United States)

    Bazavov, Alexei; Berg, Bernd A.

    2013-03-01

    A new version STMCMUCA_V1_1 of our program package is available. It eliminates compatibility problems of our Fortran 77 code, originally developed for the g77 compiler, with Fortran 90 and 95 compilers. New version program summaryProgram title: STMC_U1MUCA_v1_1 Catalogue identifier: AEET_v1_1 Licensing provisions: Standard CPC license, http://cpc.cs.qub.ac.uk/licence/licence.html Programming language: Fortran 77 compatible with Fortran 90 and 95 Computers: Any capable of compiling and executing Fortran code Operating systems: Any capable of compiling and executing Fortran code RAM: 10 MB and up depending on lattice size used No. of lines in distributed program, including test data, etc.: 15059 No. of bytes in distributed program, including test data, etc.: 215733 Keywords: Markov chain Monte Carlo, multicanonical, Wang-Landau recursion, Fortran, lattice gauge theory, U(1) gauge group, phase transitions of continuous systems Classification: 11.5 Catalogue identifier of previous version: AEET_v1_0 Journal Reference of previous version: Computer Physics Communications 180 (2009) 2339-2347 Does the new version supersede the previous version?: Yes Nature of problem: Efficient Markov chain Monte Carlo simulation of U(1) lattice gauge theory (or other continuous systems) close to its phase transition. Measurements and analysis of the action per plaquette, the specific heat, Polyakov loops and their structure factors. Solution method: Multicanonical simulations with an initial Wang-Landau recursion to determine suitable weight factors. Reweighting to physical values using logarithmic coding and calculating jackknife error bars. Reasons for the new version: The previous version was developed for the g77 compiler Fortran 77 version. Compiler errors were encountered with Fortran 90 and Fortran 95 compilers (specified below). Summary of revisions: epsilon=one/10**10 is replaced by epsilon/10.0D10 in the parameter statements of the subroutines u1_bmha.f, u1_mucabmha.f, u1wl

  4. Code for plant identification (KKS) key in PC version. KKS-Schluessel-Programm in PC-Version

    Energy Technology Data Exchange (ETDEWEB)

    Pannenbaecker, K. (GABO Gesellschaft fuer Ablauforganisation und Informationsverarbeitung mbH, Erlangen (Germany) GABO Gesellschaft fuer Ablauforganisation und Informationsverarbeitung mbH, Muenchen (Germany))

    1991-11-01

    The plant identification system (KKS) as a common development of german plant operators, erection firms and also power plant oriented organisations have decisively influenced the technical-organizing activities of planning and erections as operations and maintenance of all kind of power plants. Fundamentals are three key parts, operation, armatures and function keys. Their management and application is executed by a plantidentification-key code in a PC version, which is briefly described in this report. (orig.).

  5. WIMSD4 Version 101 and cataloged procedure

    International Nuclear Information System (INIS)

    Roth, M.J.; Taubman, C.J.; Lawrence, J.H.

    1982-06-01

    The changes made to WIMSD4 to produce Version 101 on the Harwell IBM 3033 and the Winfrith ICL 2976 computers are summarised. A detailed description of the amended catalogued procedure for executing WIMSD4 on the Harwell Computer is given. (author)

  6. Preliminary Validation of a Brazilian Version of the Sport Motivation Scale

    Directory of Open Access Journals (Sweden)

    Mauricio Bara Filho

    2011-05-01

    Full Text Available The Sport Motivation Scale was firstly developed in French and later translated into English and validated by Pelletier et al. (1995. It is based on the principles of self-determination theory. The present study translated the English version into Portuguese to access and validate it with Brazilian athletes using a sample of 419 athletes (127 women and 292 men from ten sports. The Brazilian version of the scale showed satisfactory levels of internal consistency and temporal stability over a four-week period. The results of a confirmatory factor analysis partially supported the seven-factor structure. Finally, gender differences were found in all subscales. Taken together, these findings support the use of the Brazilian version of the scale for the assessment of motivation in sport.

  7. Nifedipine as a uterine relaxant for external cephalic version: a randomized controlled trial.

    Science.gov (United States)

    Kok, Marjolein; Bais, Joke M; van Lith, Jan M; Papatsonis, Dimitri M; Kleiverda, Gunilla; Hanny, Dahrs; Doornbos, Johannes P; Mol, Ben W; van der Post, Joris A

    2008-08-01

    To estimate the effectiveness of nifedipine as a uterine relaxant during external cephalic version to correct breech presentation. In this randomized, double-blind, placebo-controlled trial, women with a singleton fetus in breech presentation and a gestational age of 36 weeks or more were eligible for enrollment. Participating women received two doses of either nifedipine 10 mg or placebo, 30 and 15 minutes before the external cephalic version attempt. The primary outcome was a cephalic-presenting fetus immediately after the procedure. Secondary outcome measures were cephalic presentation at delivery, mode of delivery, and adverse events. A sample size of 292 was calculated to provide 80% power to detect a 17% improvement of the external cephalic version success rate, assuming a placebo group rate of 40% and alpha of .05. Outcome data for 310 of 320 randomly assigned participants revealed no significant difference in external cephalic version success rates between treatment (42%) and control group (37%) (relative risk 1.1, 95%; 95% confidence interval 0.85-1.5). The cesarean delivery rate was 51% in the treatment group and 46% in the control group (relative risk 1.1, 95% confidence interval 0.88-1.4). Nifedipine did not significantly improve the success of external cephalic version. Future use of nifedipine to improve the outcome of external cephalic version should be limited to large clinical trials.

  8. DNAStat, version 2.1--a computer program for processing genetic profile databases and biostatistical calculations.

    Science.gov (United States)

    Berent, Jarosław

    2010-01-01

    This paper presents the new DNAStat version 2.1 for processing genetic profile databases and biostatistical calculations. The popularization of DNA studies employed in the judicial system has led to the necessity of developing appropriate computer programs. Such programs must, above all, address two critical problems, i.e. the broadly understood data processing and data storage, and biostatistical calculations. Moreover, in case of terrorist attacks and mass natural disasters, the ability to identify victims by searching related individuals is very important. DNAStat version 2.1 is an adequate program for such purposes. The DNAStat version 1.0 was launched in 2005. In 2006, the program was updated to 1.1 and 1.2 versions. There were, however, slight differences between those versions and the original one. The DNAStat version 2.0 was launched in 2007 and the major program improvement was an introduction of the group calculation options with the potential application to personal identification of mass disasters and terrorism victims. The last 2.1 version has the option of language selection--Polish or English, which will enhance the usage and application of the program also in other countries.

  9. WIMS-CRNL: A user's manual for the Chalk River version of WIMS

    International Nuclear Information System (INIS)

    Donnelly, J.V.

    1986-01-01

    This report describes the preparation of the input for WIMS-CRNL, the Chalk River version of the WIMS lattice code. Also included are notes on the operation of the code, contents of the associated libraries, and the relation of WIMS-CRNL to other versions of the code

  10. Reliability and validity of the Yoruba version of the Oswestry disability index.

    Science.gov (United States)

    Aiyegbusi, Ayoola Ibifubara; Akodu, Ashiyat Kehinde; Agbede, Eniolorunda Olajide

    2017-01-01

    Low back pain (LBP) is a major cause of disability, and the Oswestry Disability Index (ODI) is a validated assessment tool for evaluating disability in LBP patients. Cross-cultural adaptation of the ODI is important because not all populations are proficient in English. The Yoruba language is an indigenous language spoken by 40 million people in the Western part of Nigeria and some countries in West Africa and Latin America. Currently, no validated Yoruba version of ODI is available. The aim of the study was to translate, culturally adapt and validate the ODI in Yoruba language for participants with LBP. The ODI was translated into Yoruba, and this translated version was analysed in terms of semantics and linguistics. Then, the Yoruba version was translated back into English and both versions administered to 160 participants with LBP. The internal consistency using Cronbach's alpha coefficient, criterion validity and test-retest reliability were assessed using Spearman's rank correlation with significance set at Pdisability in LBP patients.

  11. Integrated Reliability and Risk Analysis System (IRRAS), Version 2.5: Reference manual

    International Nuclear Information System (INIS)

    Russell, K.D.; McKay, M.K.; Sattison, M.B.; Skinner, N.L.; Wood, S.T.; Rasmuson, D.M.

    1991-03-01

    The Integrated Reliability and Risk Analysis System (IRRAS) is a state-of-the-art, microcomputer-based probabilistic risk assessment (PRA) model development and analysis tool to address key nuclear plant safety issues. IRRAS is an integrated software tool that gives the user the ability to create and analyze fault trees and accident sequences using a microcomputer. This program provides functions that range from graphical fault tree construction to cut set generation and quantification. Version 1.0 of the IRRAS program was released in February of 1987. Since that time, many user comments and enhancements have been incorporated into the program providing a much more powerful and user-friendly system. This version has been designated IRRAS 2.5 and is the subject of this Reference Manual. Version 2.5 of IRRAS provides the same capabilities as Version 1.0 and adds a relational data base facility for managing the data, improved functionality, and improved algorithm performance. 7 refs., 348 figs

  12. Exploring Shared Measurement Properties and Score Comparability between Two Versions of the "Supports Intensity Scale"

    Science.gov (United States)

    Seo, Hyojeong; Shogren, Karrie A.; Wehmeyer, Michael L.; Hughes, Carolyn; Thompson, James R.; Little, Todd D.; Palmer, Susan B.

    2016-01-01

    This study examined similarities and differences in measurement properties and score comparability of the "Supports Intensity Scale-Adult Version" (16-64 years) and the "Supports Intensity Scale-Children's Version" (5-16 years). Data were collected from 142 adolescents with intellectual disability with both versions of the…

  13. Versions in the lifecycle of academic papers user requirements and guidelins fo digital repositories

    CERN Multimedia

    CERN. Geneva

    2005-01-01

    An academic research paper evolves through various stages during its lifecycle, for example from early conference presentation through working paper to final published refereed journal article. Different versions can co-exist in publicly available electronic form. Finding out researchers’ attitudes towards storing, labelling and making accessible these different versions, both of their own and of their peers’ work is at the heart of the VERSIONS Project, funded by the JISC under the Digital Repositories Programme. The project addresses the issues and uncertainties relating to versions of academic papers in digital repositories. By including a user requirements study, the project will clarify the needs of researchers and other stakeholders for deposit, storage and accessibility of different versions in the lifecycle of a digital resource. In addition to looking at user needs, the project will analyse researchers’ current practice in terms of retention of author copies of their own material. This investig...

  14. Version 4. 00 of the MINTEQ geochemical code

    Energy Technology Data Exchange (ETDEWEB)

    Eary, L.E.; Jenne, E.A.

    1992-09-01

    The MINTEQ code is a thermodynamic model that can be used to calculate solution equilibria for geochemical applications. Included in the MINTEQ code are formulations for ionic speciation, ion exchange, adsorption, solubility, redox, gas-phase equilibria, and the dissolution of finite amounts of specified solids. Since the initial development of the MINTEQ geochemical code, a number of undocumented versions of the source code and data files have come into use at the Pacific Northwest Laboratory (PNL). This report documents these changes, describes source code modifications made for the Aquifer Thermal Energy Storage (ATES) program, and provides comprehensive listings of the data files. A version number of 4.00 has been assigned to the MINTEQ source code and the individual data files described in this report.

  15. Version 4.00 of the MINTEQ geochemical code

    Energy Technology Data Exchange (ETDEWEB)

    Eary, L.E.; Jenne, E.A.

    1992-09-01

    The MINTEQ code is a thermodynamic model that can be used to calculate solution equilibria for geochemical applications. Included in the MINTEQ code are formulations for ionic speciation, ion exchange, adsorption, solubility, redox, gas-phase equilibria, and the dissolution of finite amounts of specified solids. Since the initial development of the MINTEQ geochemical code, a number of undocumented versions of the source code and data files have come into use at the Pacific Northwest Laboratory (PNL). This report documents these changes, describes source code modifications made for the Aquifer Thermal Energy Storage (ATES) program, and provides comprehensive listings of the data files. A version number of 4.00 has been assigned to the MINTEQ source code and the individual data files described in this report.

  16. NOAA/NSIDC Climate Data Record of Passive Microwave Sea Ice Concentration, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — Note: If necessary, Version 1 can be accessed by contacting the NCDC service desk at ncdc.orders@noaa.gov. However, we highly suggest using the latest version of...

  17. Comparison of two software versions for assessment of body-composition analysis by DXA

    DEFF Research Database (Denmark)

    Vozarova, B; Wang, J; Weyer, C

    2001-01-01

    To compare two software versions provided by Lunar CO: for assessment of body composition analysis by DXA.......To compare two software versions provided by Lunar CO: for assessment of body composition analysis by DXA....

  18. [External cephalic version of breech fetus after 36 weeks of gestation - evaluation of efectiveness and complications].

    Science.gov (United States)

    Hruban, L; Janků, P; Jordánová, K; Gerychová, R; Huser, M; Ventruba, P; Roztočil, A

    2017-01-01

    Evaluation of success rate and the safety of external cephalic version after 36 weeks of gestation. Retrospective analysis. Department of Obstetrics and Gynecology, Masaryk University, University Hospital Brno. A retrospective analysis of external cephalic version attempts performed on a group of 638 singleton breech pregnancies after 36 weeks gestation in the years 2003-2016 at the Department of Gynecology and Obstetrics, Masaryk University, Brno. The effectiveness, number and type of complications, mode of delivery and perinatal result were observed. The effectiveness of external cephalic version from breech to head presentation was 47.8% (305 cases). After a successful external cephalic version 238 patients (78.0%) gave birth vaginally. After unsuccessful cephalic version 130 patients (39.0%) gave birth vaginally. The number of serious complications did not exceed 0,9% and did not affect perinatal outcomes. External cephalic version-related emergency cesarean deliveries occurred in 6 cases (2 placental abruption, 4 abnormal cardiotocography). The fetal outcome was good in all these cases. The death of the fetus in connection with the external version has not occurred in our file. Spontaneous discharge of amniotic fluid within 24 hours after procedure occurred in 5 cases (0.8%). The spontaneous onset of labor within 24 hours of procedure occurred in 5 cases (0.8%). The pH value of a. umbilicalis external version and in the group with unsuccessful external version in 9 cases. The Apgar score in the 5th minute external cephalic version of the fetus in the case of breech presentation after the 36th week of pregnancy is an effective and safe alternative for women who have a fear of the vaginal breech delivery. Performing the external cephalic version can reduce the rate of elective caesarean sections due to breech presentation at term.

  19. 21 CFR 201.16 - Drugs; Spanish-language version of certain required statements.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Drugs; Spanish-language version of certain...; Spanish-language version of certain required statements. An increasing number of medications restricted to prescription use only are being labeled solely in Spanish for distribution in the Commonwealth of Puerto Rico...

  20. DEMAID - A DESIGN MANAGER'S AID FOR INTELLIGENT DECOMPOSITION (SGI IRIS VERSION)

    Science.gov (United States)

    Rogers, J. L.

    1994-01-01

    effects of an output with respect to a change in a particular input. The second method traces backward to determine what modules must be re-executed if the output of a module must be recomputed. DeMAID is available in three machine versions: a Macintosh version which is written in Symantec's Think C 3.01, a Sun version, and an SGI IRIS version, both of which are written in C language. The Macintosh version requires system software 6.0.2 or later and CLIPS 4.3. The source code for the Macintosh version will not compile under version 4.0 of Think C; however, a sample executable is provided on the distribution media. QuickDraw is required for plotting. The Sun version requires GKS 4.1 graphics libraries, OpenWindows 3, and CLIPS 4.3. The SGI IRIS version requires CLIPS 4.3. Since DeMAID is not compatible with CLIPS 5.0 or later, the source code for CLIPS 4.3 is included on the distribution media; however, the documentation for CLIPS 4.3 is not included in the documentation package for DeMAID. It is available from COSMIC separately as the documentation for MSC-21208. The standard distribution medium for the Macintosh version of DeMAID is a set of four 3.5 inch 800K Macintosh format diskettes. The standard distribution medium for the Sun version of DeMAID is a .25 inch streaming magnetic tape cartridge (QIC-24) in UNIX tar format. The standard distribution medium for the IRIS version is a .25 inch IRIX compatible streaming magnetic tape cartridge in UNIX tar format. All versions include sample input. DeMAID was originally developed for use on VAX VMS computers in 1989. The Macintosh version of DeMAID was released in 1991 and updated in 1992. The Sun version of DeMAID was released in 1992 and updated in 1993. The SGI IRIS version was released in 1993.

  1. Mode of delivery after successful external cephalic version: a systematic review and meta-analysis.

    Science.gov (United States)

    de Hundt, Marcella; Velzel, Joost; de Groot, Christianne J; Mol, Ben W; Kok, Marjolein

    2014-06-01

    To assess the mode of delivery in women after a successful external cephalic version by performing a systematic review and meta-analysis. We searched MEDLINE, Embase, ClinicalTrials.gov, Cumulative Index to Nursing and Allied Health Literature, and the Cochrane Library for studies reporting on the mode of delivery in women after successful external cephalic version at term and women with a spontaneous cephalic-presenting fetus. Two reviewers independently selected studies, extracted data, and assessed study quality. The association between mode of delivery and successful external cephalic version was expressed as a common odds ratio with a 95% confidence interval (CI). We identified three cohort studies and eight case-control studies, reporting on 46,641 women. The average cesarean delivery rate for women with a successful external cephalic version was 21%. Women after successful external cephalic version were at increased risk for cesarean delivery for dystocia (odds ratio [OR] 2.2, 95% CI 1.6-3.0), cesarean delivery for fetal distress (OR 2.2, 95% CI 1.6-2.9), and instrumental vaginal delivery (OR 1.4, 95% CI 1.1-1.7). Women who have had a successful external cephalic version for breech presentation are at increased risk for cesarean delivery and instrumental vaginal delivery as compared with women with a spontaneous cephalic presentation. Nevertheless, with a number needed to treat of three, external cephalic version still remains a very efficient procedure to prevent a cesarean delivery.

  2. Official Japanese Version of the Movement Disorder Society-Unified Parkinson's Disease Rating Scale: validation against the original English version.

    Science.gov (United States)

    Kashihara, Kenichi; Kondo, Tomoyoshi; Mizuno, Yoshikuni; Kikuchi, Seiji; Kuno, Sadako; Hasegawa, Kazuko; Hattori, Nobutaka; Mochizuki, Hideki; Mori, Hideo; Murata, Miho; Nomoto, Masahiro; Takahashi, Ryosuke; Takeda, Atsushi; Tsuboi, Yoshio; Ugawa, Yoshikazu; Yamanmoto, Mitsutoshi; Yokochi, Fusako; Yoshii, Fumihito; Stebbins, Glenn T; Tilley, Barbara C; Luo, Sheng; Wang, Lu; LaPelle, Nancy R; Goetz, Christopher G

    2014-09-01

    The Movement Disorder Society (MDS)-sponsored revision of the Unified Parkinson's Disease (PD) Rating Scale (UPDRS) (MDS-UPDRS) has been developed and is now available in English. Part of the overall program includes the establishment of official non-English translations of the MDS-UPDRS. We present the process for completing the official Japanese translation of the MDS-UPDRS with clinimetric testing results. In this trial, the MDS-UPDRS was translated into Japanese, underwent cognitive pre-testing, and the translation was modified after taking the results into account. The final translation was approved as Official Working Draft of the MDS-UPDRS Japanese version and tested in 365 native-Japanese-speaking patients with PD. Confirmatory analyses were used to determine whether the factor structure for the English-language MDS-UPDRS could be confirmed in data collected using the Official Working Draft of the Japanese translation. As a secondary analysis, we used exploratory factor analyses to examine the underlying factor structure without the constraint of a pre-specified factor organization. Confirmatory factor analysis revealed that Comparative Fit Index for all Parts of the MDS-UPDRS exceeded the minimal standard of 0.90 relative to the English version and therefore Japanese translation met the pre-specified criterion to be designated called an OFFICIAL MDS TRANSLATION. Secondary analyses revealed some differences between the English-language MDS-UPDRS and the Japanese translation, however, these differences were considered to be within an acceptable range. The Japanese version of the MDS-UPDRS met the criterion as an Official MDS Translation and is now available for use (www.movementdisorders.org).

  3. Validation of the simplified Chinese version of the Oswestry Disability Index.

    Science.gov (United States)

    Liu, Hui; Tao, Huiren; Luo, Zhuojing

    2009-05-15

    Translation, cross-cultural adaptation, and validation were performed on the Chinese version of the Oswestry Disability Index (ODI). The objective of this study was to translate and adapt the ODI into simplified Chinese and to then validate its use in Chinese patients with low back pain. A traditional Chinese version of the ODI (TCODI) has been developed and used in Hong Kong. However, there is no simplified Chinese version of the ODI (SCODI). Translation and cross-cultural adaptation of the latest version of the ODI (2.1a) were performed following instructions from the published international guidelines. The translation procedure included forward translation, back translation, and a discussion among experts. The prefinal version was tested in 40 outpatients with LBP. Then, 179 patients with LBP, including 140 outpatients and 39 inpatients, participated in the final test. They finished the SCODI, the Short-Form 36, and the Visual Analog Scale. Those 39 inpatients also finished a second ODI questionnaire within 24 hours. Last, the SCODI and TCODI were tested in another 25 inpatients for comparison. All of the patients in the prefinal test understood the simplified Chinese version correctly. In the final test, Cronbach's alpha for internal consistency was 0.93. A very high intraclass correlation coefficient was observed (ICC = 0.99) in the test-retest group. The SCODI showed a significant correlation with the 8 subscales of the Short-Form 36, especially in physical functioning (r = 0.78, P < 0.001). There was a moderate correlation between the ODI scores and the Visual Analog Scale (r = 0.69, P < 0.001). A significant difference in the mean score was demonstrated between the SCODI and the TCODI. Patients who participated in the comparison test all agreed that the SCODI was easier to understand than the TCODI. The results showed that the translation and adaptation were successful. The SCODI has proven to be valid and reliable when used in the simplified Chinese

  4. In-vessel source term analysis code TRACER version 2.3. User's manual

    International Nuclear Information System (INIS)

    Toyohara, Daisuke; Ohno, Shuji; Hamada, Hirotsugu; Miyahara, Shinya

    2005-01-01

    A computer code TRACER (Transport Phenomena of Radionuclides for Accident Consequence Evaluation of Reactor) version 2.3 has been developed to evaluate species and quantities of fission products (FPs) released into cover gas during a fuel pin failure accident in an LMFBR. The TRACER version 2.3 includes new or modified models shown below. a) Both model: a new model for FPs release from fuel. b) Modified model for FPs transfer from fuel to bubbles or sodium coolant. c) Modified model for bubbles dynamics in coolant. Computational models, input data and output data of the TRACER version 2.3 are described in this user's manual. (author)

  5. Supersymmetric versions of the Fokas–Gel’fand formula for immersion

    International Nuclear Information System (INIS)

    Bertrand, S; Grundland, A M

    2016-01-01

    In this paper, we construct and investigate two supersymmetric versions of the Fokas–Gel’fand formula for the immersion of 2D surfaces associated with a supersymmetric integrable system. The first version involves an infinitesimal deformation of the zero-curvature condition and the linear spectral problem associated with this system. This deformation leads the surfaces to be represented in terms of a bosonic supermatrix immersed in a Lie superalgebra. The second supersymmetric version is obtained by using a fermionic parameter deformation to construct surfaces expressed in terms of a fermionic supermatrix immersed in a Lie superalgebra. For both extensions, we provide a geometrical characterization of deformed surfaces using the super Killing form as an inner product and a super moving frame formalism. The theoretical results are applied to the supersymmetric sine-Gordon equation in order to construct super soliton surfaces associated with five different symmetries. We find integrated forms of these surfaces which represent constant Gaussian curvature surfaces and nonlinear Weingarten-type surfaces. (paper)

  6. An update to the Surface Ocean CO2 Atlas (SOCAT version 2)

    NARCIS (Netherlands)

    Bakker, D.C.E.; Pfeil, B.; Smith, K.; Hankin, S.; Olsen, A.; Alin, S. R.; Cosca, C.; Harasawa, S.; Kozyr, A.; Nojiri, Y.; O'Brien, K. M.; Schuster, U.; Telszewski, M.; Tilbrook, B.; Wada, C.; Akl, J.; Barbero, L.; Bates, N. R.; Boutin, J.; Bozec, Y.; Cai, W. -J.; Castle, R. D.; Chavez, F. P.; Chen, L.; Chierici, M.; Currie, K.; de Baar, H. J. W.; Evans, W.; Feely, R. A.; Fransson, A.; Gao, Z.; Hales, B.; Hardman-Mountford, N. J.; Hoppema, M.; Huang, W. -J.; Hunt, C. W.; Huss, B.; Ichikawa, T.; Johannessen, T.; Jones, E. M.; Jones, S. D.; Jutterstrom, S.; Kitidis, V.; Koertzinger, A.; Landschuetzer, P.; Lauvset, S. K.; Lefevre, N.; Manke, A. B.; Mathis, J. T.; Merlivat, L.; Metzl, N.; Murata, A.; Newberger, T.; Omar, A. M.; Ono, T.; Park, G. -H.; Paterson, K.; Pierrot, D.; Rios, A. F.; Sabine, C. L.; Saito, S.; Salisbury, J.; Sarma, V. V. S. S.; Schlitzer, R.; Sieger, R.; Skjelvan, I.; Steinhoff, T.; Sullivan, K. F.; Sun, H.; Sutton, A. J.; Suzuki, T.; Sweeney, C.; Takahashi, T.; Tjiputra, J.; Tsurushima, N.; van Heuven, S. M. A. C.; Vandemark, D.; Vlahos, P.; Wallace, D. W. R.; Wanninkhof, R.; Watson, A.J.

    2014-01-01

    The Surface Ocean CO2 Atlas (SOCAT), an activity of the international marine carbon research community, provides access to synthesis and gridded fCO(2) (fugacity of carbon dioxide) products for the surface oceans. Version 2 of SOCAT is an update of the previous release (version 1) with more data

  7. Development of single leg version of HAL for hemiplegia.

    Science.gov (United States)

    Kawamoto, Hiroaki; Hayashi, Tomohiro; Sakurai, Takeru; Eguchi, Kiyoshi; Sankai, Yoshiyuki

    2009-01-01

    Our goal is to try to enhance the QoL of persons with hemiplegia by the mean of an active motion support system based on the HAL's technology. The HAL (Hybrid Assistive Limb) in its standard version is an exoskeleton-based robot suit to support and enhance the human motor functions. The purpose of the research presented in this paper is the development of a new version of the HAL to be used as an assistive device providing walking motion support to persons with hemiplegia. It includes the realization of the single leg version of the HAL and the redesign of the original HAL's Autonomous Controller to execute human-like walking motions in an autonomous way. Clinical trials were conducted in order to assess the effectiveness of the developed system. The first stage of the trials described in this paper involved the participation of one hemiplegic patient who has difficulties to flex his right knee. As a result, the knee flexion support for walking provided by the HAL appeared to improve the subject's walking (longer stride and faster steps). The first evaluation of the system with one subject showed promising results for the future developments.

  8. Validation of Turkish version of brief negative symptom scale.

    Science.gov (United States)

    Polat Nazlı, Irmak; Ergül, Ceylan; Aydemir, Ömer; Chandhoke, Swati; Üçok, Alp; Gönül, Ali Saffet

    2016-11-01

    Negative symptoms in schizophrenia have been assessed by many instruments. However, a current consensus on these symptoms has been built and new tools, such as the Brief Negative Symptom Scale (BNSS), are generated. This study aimed to evaluate reliability and validity of the Turkish version of BNSS. The scale was translated to Turkish and backtranslated to English. After the approval of the translation, 75 schizophrenia patients were interviewed with BNSS, Positive and Negative Syndrome Scale (PANSS), Calgary Depression Scale for Schizophrenia (CDSS) and Extrapyramidal Symptom Rating Scale (ESRS). Reliability and validity analyses were then calculated. In the reliability analysis, the Cronbach's alpha coefficient was 0.96 and item-total score correlation coefficients were between 0.655-0.884. The intraclass correlation coefficient was 0.665. The inter-rater reliability was 0.982 (p Symptoms Subscale, Negative Symptoms Subscale, and General Psychopathology Subscale. CDSS and ESRS were not correlated with BNSS-TR. The factor structure of the scale was consisting the same items as in the original version. Our study confirms that the Turkish version of BNSS is an applicable tool for the evaluation of negative symptoms in schizophrenia.

  9. Is a new version of philosophical pragmatism necessary? A reply to Barnes-Holmes

    Science.gov (United States)

    Leigland, Sam

    2003-01-01

    Barnes-Holmes (2000) discussed certain issues regarding philosophy, pragmatism, and behavior analysis, and offered a “behavioral pragmatism” based on or derived from behavior-analytic perspectives. In a comparison of certain philosophical views, Quine's concept of observation sentences was employed for representing pragmatism, but this concept is not sufficiently representative of the literature of philosophical pragmatism to warrant the broad conclusions drawn by Barnes-Holmes. Further, although the extensive and diverse literature of philosophical pragmatism has been shown by a number of writers to have various themes and perspectives in common with Skinner's radical behaviorism, it is unnecessary to extract a limited, generic version of pragmatism because (a) the latter cannot match the range and depth of the various extant versions and (b) the problems raised by Barnes-Holmes in justification for the new version yield readily to the current versions in philosophy. A set of philosophical views may provide additional verbal support for a given system of science, and the science of behavior analysis may eventually contribute to philosophical discourse. The latter, however, will not be achieved by proposing new versions of old philosophy, but rather by approaching established philosophical issues in new ways. PMID:22478409

  10. Reflections on the nature of genius: on the 300th anniversay of Mikhail Lomonosov (1711-1765)

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, V.; /Fermilab

    2012-02-01

    This presentation goes beyond celebratory narration of the life and scientific achievements of Russia's first modern scientist Mikhail Vasilievich Lomonosov (1711-1765). Coming from the notion of complexity of sciences, we introduce 'a genius formula' G = TBD for semi-qualitative evaluation of a person's impact on the society, distinguish two type of geniuses, give several examples and draw general conclusions. The work largely follows presentation at the Fermilab Colloquium in November of 2011.

  11. Validity and Reliability of Persian Version of Onyx Social Capital Scale in Elderly People

    Directory of Open Access Journals (Sweden)

    Reza Eftekharian

    2016-04-01

    Conclusion: The Persian version of the questionnaire for this population has acceptable levels of face validity based on clarity, simplicity, and understandability of the questions, answers, and explanations of the Persian version of the social capital questionnaire. This version of the questionnaire also had acceptable levels in terms of suitability of the translation of the questionnaire, its suitability for Iranian community, its understandability, and suitability for needs assessment, discriminate validity (the internal consistency of the Persian version of questionnaire, test-retest reliability (absolute, and relative, and internal consistency. Therefore, this instrument is suitable for evaluating the level of social capital among the Iranian elderly people.

  12. Results from CrIS/ATMS Obtained Using an "AIRS Version-6 Like" Retrieval Algorithm

    Science.gov (United States)

    Susskind, Joel; Kouvaris, Louis; Iredell, Lena; Blaisdell, John

    2015-01-01

    AIRS and CrIS Version-6.22 O3(p) and q(p) products are both superior to those of AIRS Version-6.Monthly mean August 2014 Version-6.22 AIRS and CrIS products agree reasonably well with OMPS, CERES, and witheach other. JPL plans to process AIRS and CrIS for many months and compare interannual differences. Updates to thecalibration of both CrIS and ATMS are still being finalized. We are also working with JPL to develop a joint AIRS/CrISlevel-1 to level-3 processing system using a still to be finalized Version-7 retrieval algorithm. The NASA Goddard DISCwill eventually use this system to reprocess all AIRS and recalibrated CrIS/ATMS. .

  13. TADIR-production version: El-Op's high-resolution 480x4 TDI thermal imaging system

    Science.gov (United States)

    Sarusi, Gabby; Ziv, Natan; Zioni, O.; Gaber, J.; Shechterman, Mark S.; Lerner, M.

    1999-07-01

    Efforts invested at El-Op during the last four years have led to the development of TADIR - engineering model thermal imager, demonstrated in 1998, and eventually to the final production version of TADIR to be demonstrated in full operation during 1999. Both versions take advantage of the high resolution and high sensitivity obtained by the 480 X 4 TDI MCT detector as well as many more features implemented in the system to obtain a state of the art high- end thermal imager. The production version of TADIR uses a 480 X 6 TDI HgCdTe detector made by the SCD Israeli company. In this paper, we will present the main features of the production version of TADIR.

  14. The mathematical statement for the solving of the problem of N-version software system design

    Science.gov (United States)

    Kovalev, I. V.; Kovalev, D. I.; Zelenkov, P. V.; Voroshilova, A. A.

    2015-10-01

    The N-version programming, as a methodology of the fault-tolerant software systems design, allows successful solving of the mentioned tasks. The use of N-version programming approach turns out to be effective, since the system is constructed out of several parallel executed versions of some software module. Those versions are written to meet the same specification but by different programmers. The problem of developing an optimal structure of N-version software system presents a kind of very complex optimization problem. This causes the use of deterministic optimization methods inappropriate for solving the stated problem. In this view, exploiting heuristic strategies looks more rational. In the field of pseudo-Boolean optimization theory, the so called method of varied probabilities (MVP) has been developed to solve problems with a large dimensionality.

  15. Construction and validation of an ecological version of the Wisconsin Card Sorting Test applied to an elderly population.

    Science.gov (United States)

    Pezzuti, Lina; Mastrantonio, Elisa; Orsini, Arturo

    2013-01-01

    The goal of this project was to construct and validate an ecological version of the Wisconsin Card Sorting Test (WCST) aimed at the elderly. This was accomplished by replacing the geometric stimuli of the traditional version with stimuli belonging to the semantic category of transport vehicles, and by elimination of the color yellow. The results showed the ecological WCST version was preferred over the traditional version and older people felt less tired during test performance. In the two independent normal elderly groups, all pairs of scores that can be derived from the WCST correlated significantly with each other. Six of 11 outcome measures of the traditional WCST-128 (long) version were significantly influenced by age. By contrast, in the WCST-64 (short) version and in the ecological WCST-54 version only one measure was affected by the age variable. No significant effect of education level or gender emerged from the results in any WCST version. Again, the subjects with cognitive deterioration had lower performance in the ecological WCST-54 version than in the two traditional WCST versions. It seems reasonable to assume that the ecological version of WCST is more discriminating and has more advantages than the traditional versions. Further research on individual differences in the performance on this task will increase understanding of the components of the test, and of the variety of factors and possible deficits that could lead to an impaired performance of the test.

  16. Separate but Equal? A Comparison of Content on Library Web Pages and Their Text Versions

    Science.gov (United States)

    Hazard, Brenda L.

    2008-01-01

    This study examines the Web sites of the Association of Research Libraries member libraries to determine the presence of a separate text version of the default graphical homepage. The content of the text version and the homepage is compared. Of 121 Web sites examined, twenty libraries currently offer a text version. Ten sites maintain wholly…

  17. Global Rural-Urban Mapping Project (GRUMP), Alpha Version

    Data.gov (United States)

    National Aeronautics and Space Administration — The Global Rural-Urban Mapping Project (GRUMP), Alpha Version consists of estimates of human population for the years 1990, 1995, and 2000 by 30 arc-second (1km)...

  18. Psychometric Evaluation of the Chinese Version of the Patient Perceptions of Empowerment Scale (PPES)

    Science.gov (United States)

    Lin, Sieh-Hwa

    2014-01-01

    Objectives. To evaluate the psychometric properties of the Chinese version of the Patient Perceptions of Empowerment Scale (PPES) and to perform a cross-cultural validity assessment. Methods. In this cross-sectional survey, 554 inpatients in three general hospitals in northern Taiwan were recruited. Principal component analysis was used to examine the factor structure of the scale. Confirmatory factor analyses were conducted on the measurement model of the Chinese version of the PPES. Results. Confirmatory factor analyses supported the presence of a second-order four-factor model (information, decision, individual, and self-management) of the Chinese version of the PPES when used with a Taiwanese inpatient population. The results indicate that the 11-item, second-order, four-factor Chinese version of the PPES provided best goodness-of-fit for the data in this study. Conclusion. The 11-item four-factor Chinese version of the PPES is a self-completion scale. This study demonstrated that the Chinese version of the PPES is a reliable and valid self-report instrument for the assessment of patient perceptions of empowerment in clinical practice. Further adaptation and evaluation of the scale will hopefully stimulate further studies on PPES in the fields of psychometrics in Taiwan. PMID:24971354

  19. Psychometric Evaluation of the Chinese Version of the Patient Perceptions of Empowerment Scale (PPES

    Directory of Open Access Journals (Sweden)

    Mei-Yu Yeh

    2014-01-01

    Full Text Available Objectives. To evaluate the psychometric properties of the Chinese version of the Patient Perceptions of Empowerment Scale (PPES and to perform a cross-cultural validity assessment. Methods. In this cross-sectional survey, 554 inpatients in three general hospitals in northern Taiwan were recruited. Principal component analysis was used to examine the factor structure of the scale. Confirmatory factor analyses were conducted on the measurement model of the Chinese version of the PPES. Results. Confirmatory factor analyses supported the presence of a second-order four-factor model (information, decision, individual, and self-management of the Chinese version of the PPES when used with a Taiwanese inpatient population. The results indicate that the 11-item, second-order, four-factor Chinese version of the PPES provided best goodness-of-fit for the data in this study. Conclusion. The 11-item four-factor Chinese version of the PPES is a self-completion scale. This study demonstrated that the Chinese version of the PPES is a reliable and valid self-report instrument for the assessment of patient perceptions of empowerment in clinical practice. Further adaptation and evaluation of the scale will hopefully stimulate further studies on PPES in the fields of psychometrics in Taiwan.

  20. Cross-Cultural Adaptation and Psychometric Testing of the Brazilian Version of the Self-Care of Heart Failure Index Version 6.2

    Science.gov (United States)

    Ávila, Christiane Wahast; Riegel, Barbara; Pokorski, Simoni Chiarelli; Camey, Suzi; Silveira, Luana Claudia Jacoby; Rabelo-Silva, Eneida Rejane

    2013-01-01

    Objective. To adapt and evaluate the psychometric properties of the Brazilian version of the SCHFI v 6.2. Methods. With the approval of the original author, we conducted a complete cross-cultural adaptation of the instrument (translation, synthesis, back translation, synthesis of back translation, expert committee review, and pretesting). The adapted version was named Brazilian version of the self-care of heart failure index v 6.2. The psychometric properties assessed were face validity and content validity (by expert committee review), construct validity (convergent validity and confirmatory factor analysis), and reliability. Results. Face validity and content validity were indicative of semantic, idiomatic, experimental, and conceptual equivalence. Convergent validity was demonstrated by a significant though moderate correlation (r = −0.51) on comparison with equivalent question scores of the previously validated Brazilian European heart failure self-care behavior scale. Confirmatory factor analysis supported the original three-factor model as having the best fit, although similar results were obtained for inadequate fit indices. The reliability of the instrument, as expressed by Cronbach's alpha, was 0.40, 0.82, and 0.93 for the self-care maintenance, self-care management, and self-care confidence scales, respectively. Conclusion. The SCHFI v 6.2 was successfully adapted for use in Brazil. Nevertheless, further studies should be carried out to improve its psychometric properties. PMID:24163765

  1. Verification and validation of RADMODL Version 1.0

    International Nuclear Information System (INIS)

    Kimball, K.D.

    1993-03-01

    RADMODL is a system of linked computer codes designed to calculate the radiation environment following an accident in which nuclear materials are released. The RADMODL code and the corresponding Verification and Validation (V ampersand V) calculations (Appendix A), were developed for Westinghouse Savannah River Company (WSRC) by EGS Corporation (EGS). Each module of RADMODL is an independent code and was verified separately. The full system was validated by comparing the output of the various modules with the corresponding output of a previously verified version of the modules. The results of the verification and validation tests show that RADMODL correctly calculates the transport of radionuclides and radiation doses. As a result of this verification and validation effort, RADMODL Version 1.0 is certified for use in calculating the radiation environment following an accident

  2. A new version of the DOT 3.5

    International Nuclear Information System (INIS)

    Sbaffoni, M.M.; Abbate, M.J.

    1985-01-01

    The use of code DOT 3.5 in calculations that involve neutron thermalization processes in systems with a strong upscattering effect, has shown several problems, i.e. arise of negative fluxes, instability of the solutions, and random convergence. Because of these undesirable results, a new version of the code was developed, which maintains the possibilites of the former one and adds, as option, the utilization of a new upscattering acceleration method, called 'differential method' or 'group by group'. It is more adequate for this kind of cases and solves, with the addition of a few other minor modifications, the above mentioned problems. Since this new version includes the original one, the modifications described in this report, in particular those of input and output features, are an addendum to the corresponding user's manual. (author) [es

  3. Verification and validation of RADMODL Version 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Kimball, K.D.

    1993-03-01

    RADMODL is a system of linked computer codes designed to calculate the radiation environment following an accident in which nuclear materials are released. The RADMODL code and the corresponding Verification and Validation (V&V) calculations (Appendix A), were developed for Westinghouse Savannah River Company (WSRC) by EGS Corporation (EGS). Each module of RADMODL is an independent code and was verified separately. The full system was validated by comparing the output of the various modules with the corresponding output of a previously verified version of the modules. The results of the verification and validation tests show that RADMODL correctly calculates the transport of radionuclides and radiation doses. As a result of this verification and validation effort, RADMODL Version 1.0 is certified for use in calculating the radiation environment following an accident.

  4. Latest NASA Instrument Cost Model (NICM): Version VI

    Science.gov (United States)

    Mrozinski, Joe; Habib-Agahi, Hamid; Fox, George; Ball, Gary

    2014-01-01

    The NASA Instrument Cost Model, NICM, is a suite of tools which allow for probabilistic cost estimation of NASA's space-flight instruments at both the system and subsystem level. NICM also includes the ability to perform cost by analogy as well as joint confidence level (JCL) analysis. The latest version of NICM, Version VI, was released in Spring 2014. This paper will focus on the new features released with NICM VI, which include: 1) The NICM-E cost estimating relationship, which is applicable for instruments flying on Explorer-like class missions; 2) The new cluster analysis ability which, alongside the results of the parametric cost estimation for the user's instrument, also provides a visualization of the user's instrument's similarity to previously flown instruments; and 3) includes new cost estimating relationships for in-situ instruments.

  5. Validity and Reliability of the Catastrophic Cognitions Questionnaire-Turkish Version

    Directory of Open Access Journals (Sweden)

    Ayse Kart

    2016-01-01

    Full Text Available Aim: Importance of catastrophic cognitions is well known for the development and maintance of panic disorder. Catastrophic Cognitions Questionnaire (CCQ measures thoughts associated with danger and was originally developed by Khawaja (1992. In this study, it is aimed to evaluate the validity and reliability of CCQ- Turkish version. Material and Method: CCQ was administered to 250 patients with panic disorder. Turkish version of CCQ was created by translation, back-translation and pilot assessment. Socio-demographic Data Form and CCQ Turkish version were administered to participants. Reliability of CCQ was analyzed by test-retest correlation, split-half technique, Cronbach%u2019s alpha coefficient. Construct validity was evaluated by factor analysis after the Kaiser-Meyer-Olkin (KMO and Bartlett test had been performed. Principal component analysis and varimax rotation were used for factor analysis. Results: Fifty-five point six percent (n=139 of the participants were female and fourty-four point four percent (n=111 were male. Internal consistency of the questionnaire was calculated 0.920 by Cronbach alpha. In analysis performed by split-half method reliability coefficients of half questionnaire were found as 0.917 and 0.832. Again spearmen-brown coefficient was found as 0.875 by the same analysis. Factor analysis revealed five basic factors. These five factors explained %66.2 of the total variance. Discussion: The results of this study show that the Turkish version of CCQ is a reliable and valid scale.

  6. Generation and tests of the new version 88 library for HAMMER system

    International Nuclear Information System (INIS)

    Chalhoub, E.S.; Anaf, J.

    1988-08-01

    A new library, version 88, for the HAMMER system, was generated using the ENDF/B-IV FRENDL evaluated nuclear data libraries. It is composed of epithermal and thermal libraries obtained by processing the new versions of ETOG-3 and FLANGE-II codes, respectively. Test results for two benchmark critical assemblies are presented. (author) [pt

  7. Validation of the Brazilian Portuguese version of the pelvic floor bother questionnaire.

    Science.gov (United States)

    Peterson, Thais Villela; Pinto, Rodrigo Ambar; Davila, G Willy; Nahas, Sérgio Carlos; Baracat, Edmund Chada; Haddad, Jorge Milhem

    2018-03-16

    The Pelvic Floor Bother Questionnaire (PFBQ) was designed to identify the presence and degree of bother associated with common pelvic floor symptoms. The PFBQ can be used in clinical practice and for research purposes, but it is not available in Brazilian Portuguese. We aimed to validate a cross-culturally adapted Brazilian Portuguese version of the PFBQ. A pilot-tested version of the PFBQ translated from English was evaluated with Brazilian patients suffering from pelvic floor disorders. Internal reliability, test-retest reliability, validity, and responsiveness to change were assessed. A total of 147 patients (mean age, 60.49 years) were enrolled in the study. The Brazilian Portuguese version of the PFBQ demonstrated good reliability (α = 0.625; ICC = 0.981). There was strong agreement beyond chance for each item (κ = 0.895-1.00). The PFBQ correlated with stage of prolapse (p Portuguese version of the PFBQ is a reliable, valid, and user-friendly instrument that can be used for assessing the presence and severity of pelvic floor symptoms in clinical and research settings in Brazil.

  8. Integrated Reliability and Risk Analysis System (IRRAS) Version 2.0 user's guide

    International Nuclear Information System (INIS)

    Russell, K.D.; Sattison, M.B.; Rasmuson, D.M.

    1990-06-01

    The Integrated Reliability and Risk Analysis System (IRRAS) is a state-of-the-art, microcomputer-based probabilistic risk assessment (PRA) model development and analysis tool to address key nuclear plant safety issues. IRRAS is an integrated software tool that gives the user the ability to create and analyze fault trees and accident sequences using a microcomputer. This program provides functions that range from graphical fault tree construction to cut set generation and quantification. Also provided in the system is an integrated full-screen editor for use when interfacing with remote mainframe computer systems. Version 1.0 of the IRRAS program was released in February of 1987. Since that time, many user comments and enhancements have been incorporated into the program providing a much more powerful and user-friendly system. This version has been designated IRRAS 2.0 and is the subject of this user's guide. Version 2.0 of IRRAS provides all of the same capabilities as Version 1.0 and adds a relational data base facility for managing the data, improved functionality, and improved algorithm performance. 9 refs., 292 figs., 4 tabs

  9. Fuzzy Versions of Epistemic and Deontic Logic

    Science.gov (United States)

    Gounder, Ramasamy S.; Esterline, Albert C.

    1998-01-01

    Epistemic and deontic logics are modal logics, respectively, of knowledge and of the normative concepts of obligation, permission, and prohibition. Epistemic logic is useful in formalizing systems of communicating processes and knowledge and belief in AI (Artificial Intelligence). Deontic logic is useful in computer science wherever we must distinguish between actual and ideal behavior, as in fault tolerance and database integrity constraints. We here discuss fuzzy versions of these logics. In the crisp versions, various axioms correspond to various properties of the structures used in defining the semantics of the logics. Thus, any axiomatic theory will be characterized not only by its axioms but also by the set of properties holding of the corresponding semantic structures. Fuzzy logic does not proceed with axiomatic systems, but fuzzy versions of the semantic properties exist and can be shown to correspond to some of the axioms for the crisp systems in special ways that support dependency networks among assertions in a modal domain. This in turn allows one to implement truth maintenance systems. For the technical development of epistemic logic, and for that of deontic logic. To our knowledge, we are the first to address fuzzy epistemic and fuzzy deontic logic explicitly and to consider the different systems and semantic properties available. We give the syntax and semantics of epistemic logic and discuss the correspondence between axioms of epistemic logic and properties of semantic structures. The same topics are covered for deontic logic. Fuzzy epistemic and fuzzy deontic logic discusses the relationship between axioms and semantic properties for these logics. Our results can be exploited in truth maintenance systems.

  10. PAV ontology: provenance, authoring and versioning.

    Science.gov (United States)

    Ciccarese, Paolo; Soiland-Reyes, Stian; Belhajjame, Khalid; Gray, Alasdair Jg; Goble, Carole; Clark, Tim

    2013-11-22

    Provenance is a critical ingredient for establishing trust of published scientific content. This is true whether we are considering a data set, a computational workflow, a peer-reviewed publication or a simple scientific claim with supportive evidence. Existing vocabularies such as Dublin Core Terms (DC Terms) and the W3C Provenance Ontology (PROV-O) are domain-independent and general-purpose and they allow and encourage for extensions to cover more specific needs. In particular, to track authoring and versioning information of web resources, PROV-O provides a basic methodology but not any specific classes and properties for identifying or distinguishing between the various roles assumed by agents manipulating digital artifacts, such as author, contributor and curator. We present the Provenance, Authoring and Versioning ontology (PAV, namespace http://purl.org/pav/): a lightweight ontology for capturing "just enough" descriptions essential for tracking the provenance, authoring and versioning of web resources. We argue that such descriptions are essential for digital scientific content. PAV distinguishes between contributors, authors and curators of content and creators of representations in addition to the provenance of originating resources that have been accessed, transformed and consumed. We explore five projects (and communities) that have adopted PAV illustrating their usage through concrete examples. Moreover, we present mappings that show how PAV extends the W3C PROV-O ontology to support broader interoperability. The initial design of the PAV ontology was driven by requirements from the AlzSWAN project with further requirements incorporated later from other projects detailed in this paper. The authors strived to keep PAV lightweight and compact by including only those terms that have demonstrated to be pragmatically useful in existing applications, and by recommending terms from existing ontologies when plausible. We analyze and compare PAV with related

  11. Reliability and validity of the Danish version of the UCLA Loneliness Scale

    DEFF Research Database (Denmark)

    Lasgaard, Mathias

    2007-01-01

    The objective of this study was to examine the psychometric properties of a Danish version of the UCLA Loneliness Scale (UCLA). The 20-item scale was completed along with other measures in a national youth probability sample of 379 8th grade students aged 13-17. The scale showed high internal con....... The results, highly comparable to the original version of the scale, indicate that the Danish version of UCLA is a reliable and valid measure of loneliness....... consistency, and correlations between UCLA and measures of emotional loneliness, social loneliness, self-esteem, depression, extraversion, and neuroticism supported the convergent and discriminant validity of the scale. Exploratory factor analysis supported a unidimensional structure of the measure...

  12. Development of the short version of the informal caregiver burden assessment questionnaire

    Directory of Open Access Journals (Sweden)

    Teresa Martins

    2015-04-01

    Full Text Available OBJETIVE to create a reduced version of the QASCI, which is structurally equivalent to the long one and meets the criteria of reliability and validity. METHOD Through secondary data from previous studies, the participants were divided into two samples, one for the development of reduced version and the second for study of the factorial validity. Participants responded to QASCI, the SF 36, the ADHS and demographic questions. RESULTS A reduced version of 14 items showed adequate psychometric properties of validity and internal consistency, adapted to a heptadimensional structure that assesses positive and negative aspects of care. CONCLUSION Confirmatory factor analysis revealed a good fit with the advocated theoretical model.

  13. Continuous-energy version of KENO V.a for criticality safety applications

    International Nuclear Information System (INIS)

    Dunn, Michael E.; Greene, N. Maurice; Petrie, Lester M.

    2003-01-01

    KENO V.a is a multigroup Monte Carlo code that solves the Boltzmann transport equation and is used extensively in the criticality safety community to calculate the effective multiplication factor of systems with fissionable material. In this work, a continuous-energy or pointwise version of KENO V.a has been developed by first designing a new continuous-energy cross-section format and then by developing the appropriate Monte Carlo transport procedures to sample the new cross-section format. In order to generate pointwise cross sections for a test library, a series of cross-section processing modules were developed and used to process 50 ENDF/B-6 Release 7 nuclides for the test library. Once the cross-section processing procedures were in place, a continuous-energy version of KENO V.a was developed and tested by calculating 21 critical benchmark experiments. The point KENO-calculated results for the 21 benchmarks are in agreement with calculated results obtained with the multigroup version of KENO V.a using the 238-group ENDF/B-5 and 199-group ENDF/B-6 Release 3 libraries. Based on the calculated results with the prototypic cross-section library, a continuous-energy version of the KENO V.a code has been successfully developed and demonstrated for modeling systems with fissionable material. (author)

  14. Various versions of analytic QCD and skeleton-motivated evaluation of observables

    International Nuclear Information System (INIS)

    Cvetic, Gorazd; Valenzuela, Cristian

    2006-01-01

    We present skeleton-motivated evaluation of QCD observables. The approach can be applied in analytic versions of QCD in certain classes of renormalization schemes. We present two versions of analytic QCD which can be regarded as low-energy modifications of the ''minimal'' analytic QCD and which reproduce the measured value of the semihadronic τ decay ratio r τ . Further, we describe an approach of calculating the higher-order analytic couplings A k (k=2,3,...) on the basis of logarithmic derivatives of the analytic coupling A 1 (Q 2 ). This approach can be applied in any version of analytic QCD. We adjust the free parameters of the aforementioned two analytic models in such a way that the skeleton-motivated evaluation reproduces the correct known values of r τ and of the Bjorken polarized sum rule (BjPSR) d b (Q 2 ) at a given point (e.g., at Q 2 =2 GeV 2 ). We then evaluate the low-energy behavior of the Adler function d v (Q 2 ) and the BjPSR d b (Q 2 ) in the aforementioned evaluation approach, in the three analytic versions of QCD. We compare with the results obtained in the minimal analytic QCD and with the evaluation approach of Milton et al. and Shirkov

  15. Particle and heavy ion transport code system, PHITS, version 2.52

    International Nuclear Information System (INIS)

    Sato, Tatsuhiko; Matsuda, Norihiro; Hashimoto, Shintaro; Iwamoto, Yosuke; Noda, Shusaku; Ogawa, Tatsuhiko; Nakashima, Hiroshi; Fukahori, Tokio; Okumura, Keisuke; Kai, Tetsuya; Niita, Koji; Iwase, Hiroshi; Chiba, Satoshi; Furuta, Takuya; Sihver, Lembit

    2013-01-01

    An upgraded version of the Particle and Heavy Ion Transport code System, PHITS2.52, was developed and released to the public. The new version has been greatly improved from the previously released version, PHITS2.24, in terms of not only the code itself but also the contents of its package, such as the attached data libraries. In the new version, a higher accuracy of simulation was achieved by implementing several latest nuclear reaction models. The reliability of the simulation was improved by modifying both the algorithms for the electron-, positron-, and photon-transport simulations and the procedure for calculating the statistical uncertainties of the tally results. Estimation of the time evolution of radioactivity became feasible by incorporating the activation calculation program DCHAIN-SP into the new package. The efficiency of the simulation was also improved as a result of the implementation of shared-memory parallelization and the optimization of several time-consuming algorithms. Furthermore, a number of new user-support tools and functions that help users to intuitively and effectively perform PHITS simulations were developed and incorporated. Due to these improvements, PHITS is now a more powerful tool for particle transport simulation applicable to various research and development fields, such as nuclear technology, accelerator design, medical physics, and cosmic-ray research. (author)

  16. Cross-cultural Adaptation, Reliability, and Validity of the Yoruba Version of the Roland-Morris Disability Questionnaire.

    Science.gov (United States)

    Mbada, Chidozie Emmanuel; Idowu, Opeyemi Ayodiipo; Ogunjimi, Olawale Richard; Ayanniyi, Olusola; Orimolade, Elkanah Ayodele; Oladiran, Ajibola Babatunde; Johnson, Olubusola Esther; Akinsulore, Adesanmi; Oni, Temitope Olawale

    2017-04-01

    A translation, cross-cultural adaptation, and psychometric analysis. The aim of this study was to translate, cross-culturally adapt, and validate the Yoruba version of the RMDQ. The Roland-Morris Disability Questionnaire (RMDQ) is a valid outcome tool for low back pain (LBP) in clinical and research settings. There seems to be no valid and reliable version of the RMDQ in the Nigerian languages. Following the Guillemin criteria, the English version of the RMDQ was forward and back translated. Two Yoruba translated versions of the RMDQ were assessed for clarity, common language usage, and conceptual equivalence. Consequently, a harmonized Yoruba version was produced and was pilot-tested among 20 patients with nonspecific long-term LBP (NSLBP) for cognitive debriefing. The final version of the Yoruba RMDQ was tested for its construct validity and re-retest reliability among 120 and 87 patients with NSLBP, respectively. Pearson product moment correlation coefficient (r) of 0.82 was obtained for reliability of the Yoruba version of the RMDQ. The test-retest reliability of the Yoruba RMDQ yielded Cronbach alpha 0.932, while the intraclass correlation (ICC) ranged between 0.896 and 0.956. The analysis of the global scores of both the English and Yoruba versions of the RMDQ yielded ICC value of between 0.995 (95% confidence interval 0.996-0.997), with the item-by-item Kappa agreement ranging between 0.824 and 1.000. The external validity of RMDQ using Quadruple Visual Analogue Scale was r = -0.596 (P = 0.001). The Yoruba version of the RMDQ had no floor/ceiling effects, as no patient achieved either of the maximum or the minimum possible scores. The Yoruba version of the RMDQ has excellent reliability and validity and may be an appropriate outcome tool for clinical and research purposes among Yoruba-speaking patients with LBP. 3.

  17. Procedure guideline for thyroid scintigraphy (version 3); Verfahrensanweisung fuer die Schilddruesenszintigraphie (Version 3)

    Energy Technology Data Exchange (ETDEWEB)

    Dietlein, M.; Schicha, H. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Dressler, J. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Nuklearmedizinische Klinik der Henriettenstiftung, Hannover (Germany); Eschner, W. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Deutsche Gesellschaft fuer Medizinische Physik (DGMP) (Germany); Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Leisner, B. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Allgemeines Krankenhaus St. Georg, Hamburg (Germany). Abt. fuer Nuklearmedizin; Reiners, C. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    2007-07-01

    The version 3 of the procedure guideline for thyroid scintigraphy is an update of the procedure guideline previously published in 2003. The interpretation of the scintigraphy requires the knowledge of the patients' history, the palpation of the neck, the laboratory parameters and of the sonography. The interpretation of the technetium-99m uptake requires the knowledge of the TSH-level. As a consequence of the improved alimentary iodine supply the {sup 99m}Tc-uptake has decreased; 100 000 counts per scintigraphy should be acquired. For this, an imaging time of 10 minutes is generally needed using a high resolution collimator for thyroid imaging. (orig.)

  18. WIMS-IJSO - An extended version of the WIMS group constant library

    International Nuclear Information System (INIS)

    Trkov, A.; Perdan, A.

    1982-11-01

    WIMS-IJSO is a preliminary extended version of the WIMS library as supplied with the CDC version of the S-WIMS-code. It is a result of the feasibility study of the possibility to update and extend the WIMS library. In the course of its preparation valuable experience was gained in understanding the definitions, the conventions and the structure of the WIMS library. This experience will be used in the preparation of an extended WIMS library for some materials from carefully chosen evaluated data. The library as supplied with the WIMS-D4 package will be used as the basis. The materials added to the library had been tested in reactor calculations and their performance was found to be satisfactory. The aim of releasing the preliminary version of the WIMS library is to allow different users to apply the data to various problems

  19. The benefit of external cephalic version with tocolysis as a routine procedure in late pregnancy

    DEFF Research Database (Denmark)

    Thunedborg, P; Fischer-Rasmussen, W; Tollund, L

    1991-01-01

    The effectiveness of external cephalic version with tocolysis when routinely used in the 37th week of gestation is reported. The procedure had earlier been ruled out in our department, was found effective in a prospective study, and afterwards settled as a routine. Among 1038 women with single...... breech presentation, 882 could be offered an attempt of external cephalic version during the period 1982-1988. Attempt of version was carried out in 316 women resulting in a vertex presentation at delivery in 100. The success rate on average was 35%. The estimated reduction of breech deliveries was 100...... serious complications were associated with the procedure. Two cases of intra-uterine fetal death occurred 2 and 5 weeks, respectively, after successful, uncomplicated version to vertex presentation. No obvious connection with the external cephalic version could be demonstrated. The effectiveness...

  20. Geostationary Surface and Insolation Products (GSIP), Version 3

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Geostationary Surface and Insolation Products (GSIP) Version 3 contains upwelling and downwelling shortwave (0.2-4.0 um) and visible (0.4-0.7 um) radiative...

  1. The Internalized Stigma of Mental Illness (ISMI) scale: validation of the Japanese version.

    Science.gov (United States)

    Tanabe, Yosuke; Hayashi, Kunihiko; Ideno, Yuki

    2016-04-29

    The present study investigated the reliability and validity of a Japanese version of the Internalized Stigma of Mental Illness (ISMI) scale, designed to assess internalized stigma experienced by people with mental illness. A survey was conducted with 173 outpatients with mental illness who attended psychiatric clinics on a regular basis. A retest was conducted with 51 participants to evaluate the scale's psychometric properties. The alpha coefficient for the overall internal consistency was 0.91, and the coefficients of the individual ISMI subscales ranged from 0.57 to 0.81. The test-retest reliability was r = 0.85 (n = 51, P stigma resistance items excluded. The Japanese version of the ISMI scale demonstrated similar reliability and validity to the original English version. Therefore, the Japanese version of the ISMI scale may be an effective and valid tool to measure internalized stigma among Japanese people who have a mental illness.

  2. Release Early, Release Often: Predicting Change in Versioned Knowledge Organization Systems on the Web

    OpenAIRE

    Meroño-Peñuela, Albert; Guéret, Christophe; Schlobach, Stefan

    2015-01-01

    The Semantic Web is built on top of Knowledge Organization Systems (KOS) (vocabularies, ontologies, concept schemes) that provide a structured, interoperable and distributed access to Linked Data on the Web. The maintenance of these KOS over time has produced a number of KOS version chains: subsequent unique version identifiers to unique states of a KOS. However, the release of new KOS versions pose challenges to both KOS publishers and users. For publishers, updating a KOS is a knowledge int...

  3. Translation and validation of the Malay version of the Stroke Knowledge Test.

    Science.gov (United States)

    Sowtali, Siti Noorkhairina; Yusoff, Dariah Mohd; Harith, Sakinah; Mohamed, Monniaty

    2016-04-01

    To date, there is a lack of published studies on assessment tools to evaluate the effectiveness of stroke education programs. This study developed and validated the Malay language version of the Stroke Knowledge Test research instrument. This study involved translation, validity, and reliability phases. The instrument underwent backward and forward translation of the English version into the Malay language. Nine experts reviewed the content for consistency, clarity, difficulty, and suitability for inclusion. Perceived usefulness and utilization were obtained from experts' opinions. Later, face validity assessment was conducted with 10 stroke patients to determine appropriateness of sentences and grammar used. A pilot study was conducted with 41 stroke patients to determine the item analysis and reliability of the translated instrument using the Kuder Richardson 20 or Cronbach's alpha. The final Malay version Stroke Knowledge Test included 20 items with good content coverage, acceptable item properties, and positive expert review ratings. Psychometric investigations suggest that Malay version Stroke Knowledge Test had moderate reliability with Kuder Richardson 20 or Cronbach's alpha of 0.58. Improvement is required for Stroke Knowledge Test items with unacceptable difficulty indices. Overall, the average rating of perceived usefulness and perceived utility of the instruments were both 72.7%, suggesting that reviewers were likely to use the instruments in their facilities. Malay version Stroke Knowledge Test was a valid and reliable tool to assess educational needs and to evaluate stroke knowledge among participants of group-based stroke education programs in Malaysia.

  4. Psychometric properties of the Norwegian version of the Safety Attitudes Questionnaire (SAQ, Generic version (Short Form 2006

    Directory of Open Access Journals (Sweden)

    Hofoss Dag

    2008-09-01

    Full Text Available Abstract Background How to protect patients from harm is a question of universal interest. Measuring and improving safety culture in care giving units is an important strategy for promoting a safe environment for patients. The Safety Attitudes Questionnaire (SAQ is the only instrument that measures safety culture in a way which correlates with patient outcome. We have translated the SAQ to Norwegian and validated the translated version. The psychometric properties of the translated questionnaire are presented in this article. Methods The questionnaire was translated with the back translation technique and tested in 47 clinical units in a Norwegian university hospital. SAQ's (the Generic version (Short Form 2006 the version with the two sets of questions on perceptions of management: on unit management and on hospital management were distributed to 1911 frontline staff. 762 were distributed during unit meetings and 1149 through the postal system. Cronbach alphas, item-to-own correlations, and test-retest correlations were calculated, and response distribution analysis and confirmatory factor analysis were performed, as well as early validity tests. Results 1306 staff members completed and returned the questionnaire: a response rate of 68%. Questionnaire acceptability was good. The reliability measures were acceptable. The factor structure of the responses was tested by confirmatory factor analysis. 36 items were ascribed to seven underlying factors: Teamwork Climate, Safety Climate, Stress Recognition, Perceptions of Hospital Management, Perceptions of Unit Management, Working conditions, and Job satisfaction. Goodness-of-Fit Indices showed reasonable, but not indisputable, model fit. External validity indicators – recognizability of results, correlations with "trigger tool"-identified adverse events, with patient satisfaction with hospitalization, patient reports of possible maltreatment, and patient evaluation of organization of hospital work

  5. TRASYS - THERMAL RADIATION ANALYZER SYSTEM (CRAY VERSION WITH NASADIG)

    Science.gov (United States)

    Anderson, G. E.

    1994-01-01

    . The flexible structure of TRASYS allows considerable freedom in the definition and choice of solution method for a thermal radiation problem. The program's flexible structure has also allowed TRASYS to retain the same basic input structure as the authors update it in order to keep up with changing requirements. Among its other important features are the following: 1) up to 3200 node problem size capability with shadowing by intervening opaque or semi-transparent surfaces; 2) choice of diffuse, specular, or diffuse/specular radiant interchange solutions; 3) a restart capability that minimizes recomputing; 4) macroinstructions that automatically provide the executive logic for orbit generation that optimizes the use of previously completed computations; 5) a time variable geometry package that provides automatic pointing of the various parts of an articulated spacecraft and an automatic look-back feature that eliminates redundant form factor calculations; 6) capability to specify submodel names to identify sets of surfaces or components as an entity; and 7) subroutines to perform functions which save and recall the internodal and/or space form factors in subsequent steps for nodes with fixed geometry during a variable geometry run. There are two machine versions of TRASYS v27: a DEC VAX version and a Cray UNICOS version. Both versions require installation of the NASADIG library (MSC-21801 for DEC VAX or COS-10049 for CRAY), which is available from COSMIC either separately or bundled with TRASYS. The NASADIG (NASA Device Independent Graphics Library) plot package provides a pictorial representation of input geometry, orbital/orientation parameters, and heating rate output as a function of time. NASADIG supports Tektronix terminals. The CRAY version of TRASYS v27 is written in FORTRAN 77 for batch or interactive execution and has been implemented on CRAY X-MP and CRAY Y-MP series computers running UNICOS. The standard distribution medium for MSC-21959 (CRAY version

  6. A Japanese version of the Rosenberg Self-Esteem Scale: translation and equivalence assessment.

    Science.gov (United States)

    Mimura, Chizu; Griffiths, Peter

    2007-05-01

    A Japanese version of the Rosenberg Self-Esteem Scale (RSES) was developed through the forward-backward translation procedure. Married couples consisting of a native English speaker and a native Japanese speaker acted as translators to enhance the representativeness of language in the target population. Multiple translations were produced, and a panel of reviewers identified problems in conceptual and semantic equivalence between the original scale and the translated version. The Japanese version was altered accordingly with reference to alternate Japanese forms from the original English to Japanese translations. The altered translation was again retranslated into English, and problematic differences were checked. This forward-backward process was repeated until satisfactory agreement had been attained. The RSES was administered to 222 native English speakers, and the developed Japanese version (RSES-J) was administered to 1320 native Japanese speakers. Factor analysis revealed nearly identical factor structure and structural coefficients of the items between two sets of data. Target rotation confirmed the factorial agreement of the two scales in different cultural groups. High Cronbach's alpha coefficients supported the reliability of test scores on both versions. The equivalence between the RSES and the RSES-J was supported in this study. It is suggested that the RSES and the RSES-J are potential tools for comparative cross-cultural studies.

  7. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD).

    Science.gov (United States)

    Nitschke, Ashley; Lambert, Jeffery R; Glueck, Deborah H; Jesse, Mary Kristen; Mei-Dan, Omer; Strickland, Colin; Petersen, Brian

    2015-11-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p TAD (p TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain.

  8. GOES Surface and Insolation Products (GSIP), Version 2

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Version 2 of the GOES Surface and Insolation Products (GSIP) is a high spatial resolution (1/8 x 1/8 degrees) solar radiation product estimated from the GOES-East...

  9. Extensions of MAD Version 8 to Include Beam Acceleration

    International Nuclear Information System (INIS)

    Raubenheimer, Tor O

    2000-01-01

    In this paper, the authors describe modifications to MAD version 8.23 to include linear accelerator cavities and beam acceleration. An additional energy variable has been added which is modified as the beam passes through LCAV elements (linear accelerator cavities) and can be used as a constraint in matching commands. The calculation of the beta functions and phase advance is consistent with that in other codes that treat acceleration such as TRANSPORT or DIMAD. These modifications allow this version of MAD to be used for the design and modeling of linacs and the authors present examples from the Next Linear Collider design as well as a muon acceleration complex. The code is available from CERN or SLAC

  10. Predictors of successful outcomes after external cephalic version in singleton term breech pregnancies: a nine-year historical cohort study.

    Science.gov (United States)

    Cho, L Y; Lau, W L; Lo, T K; Tang, Helen H T; Leung, W C

    2012-02-01

    To study the success rate, predictors for success, and pregnancy outcomes after external cephalic version. Historical cohort study. Regional hospital, Hong Kong. All women who had singleton term breech pregnancies at term and opted for external cephalic version during 2001 and 2009. Their demographic data, clinical and ultrasound findings, procedure details, complications, and delivery outcomes were analysed. Predictive factors for successful external cephalic version. A total of 209 external cephalic versions were performed during the 9-year period. The success rate was 63% (75% for multiparous and 53% for nulliparous women). There was no significant complication. On univariate analysis, predictors of successful external cephalic version were: multiparity, unengaged presenting part, higher amniotic fluid index (≥ 10 cm), thin abdominal wall, low uterine tone, and easily palpable fetal head (subjective assessment by practitioners before external cephalic version). On multivariate analysis, only multiparity, non-engagement of the fetal buttock and thin maternal abdomen were associated with successful external cephalic version. In all, 69% of those who had successful external cephalic version succeeded in the first roll (Pexternal cephalic versions had vaginal deliveries (93% in multiparous and 69% in nulliparous women). Uptake rate of external cephalic version was studied in the latter part of the study period (2006-2009). Whilst 735 women were eligible for external cephalic version, 131 women chose to have the procedure resulting in an uptake rate of 18%. External cephalic version was effective in reducing breech presentations at term and corresponding caesarean section rates, but the uptake rate was low. Further work should address the barriers to the low acceptance of external cephalic version. The results of this study could encourage women to opt for external cephalic version.

  11. Does internal podalic version of the non-vertex second twin still have a place in obstetrics?

    DEFF Research Database (Denmark)

    Jonsdottir, Fjola; Stokholm, Lonny Merete; Secher, Niels Jørgen

    2015-01-01

    of delivery mode, 5-min Apgar score, asphyxia, umbilical cord pH, admission to neonatal intensive care unit, treatment by mechanical ventilation, and experience level of obstetricians performing internal podalic version. RESULTS: 457 births were available for analysis: 39 cases of internal podalic version...... version than the cesarean section group, however, fewer cases needed mechanical ventilation. Thirty internal versions and breech extractions were performed by obstetricians with >5 years clinical experience and three by trainees. CONCLUSION: Cesarean sections for a second twin seem to have been frequent...

  12. TRANSLATION, VALIDATION AND PSYCHOMETRIC EVALUATION OF PROBLEM AREAS IN DIABETES QUESTIONNAIRE: THE URDU VERSION

    OpenAIRE

    Sajjad Haider, Marvi Baloch, Qaiser Iqbal and Fahad Saleem

    2017-01-01

    Objective: The study aims to translate and examine the psychometric properties of the Urdu version of Problem Areas in Diabetes (PAID) questionnaire among Type 2 diabetic patients (T2DM) in Quetta, Pakistan. Method: A standard ‘‘forward–backward’’ procedure of translation was used to translate the English version of PAID into Urdu (official language of Pakistan). The translated version was then validated on a convenience sample of 120 T2DM patients attending a public hospital in Quetta, Pakis...

  13. Psychometric Properties of the Iranian Version of the Premature Ejaculation Diagnostic Tool

    Directory of Open Access Journals (Sweden)

    Amir H. Pakpour, PhD

    2014-04-01

    Conclusion: The results provide evidence for good reliability and validity of the Iranian version of the PEDT. The questionnaire therefore represents a suitable tool for screening PE in Iranian men. Pakpour AH, Yekaninejad MS, Nikoobakht MR, Burri A, and Fridlund B. Psychometric properties of the Iranian version of the Premature Ejaculation Diagnostic Tool. Sex Med 2014;2:31–40.

  14. Herth hope index: psychometric testing of the Chinese version.

    Science.gov (United States)

    Chan, Keung Sum; Li, Ho Cheung William; Chan, Sally Wai-Chi; Lopez, Violeta

    2012-09-01

    This article is a report on psychometric testing of the Chinese version of the herth hope index. The availability of a valid and reliable instrument that accurately measures the level of hope in patients with heart failure is crucial before any hope-enhancing interventions can be appropriately planned and evaluated. There is no such instrument for Chinese people. A test-retest, within-subjects design was used. A purposive sample of 120 Hong Kong Chinese patients with heart failure between the ages of 60 and 80 years admitted to two medical wards was recruited during an 8-month period in 2009. Participants were asked to respond to the Chinese version of the herth hope index, Hamilton depression rating scale and Rosenberg's self-esteem scale. The internal consistency, content validity and construct validity and test-retest reliability of the Chinese version of the herth hope index were assessed. The newly translated scale demonstrated adequate internal consistency, good content validity and appropriate convergent and discriminant validity. Confirmatory factor analysis added further evidence of the construct validity of the scale. Results suggest that the newly translated scale can be used as a self-report assessment tool in assessing the level of hope in Hong Kong Chinese patients with heart failure. © 2011 Blackwell Publishing Ltd.

  15. Reliability and Validity of the Turkish Version of the Job Performance Scale Instrument.

    Science.gov (United States)

    Harmanci Seren, Arzu Kader; Tuna, Rujnan; Eskin Bacaksiz, Feride

    2018-02-01

    Objective measurement of the job performance of nursing staff using valid and reliable instruments is important in the evaluation of healthcare quality. A current, valid, and reliable instrument that specifically measures the performance of nurses is required for this purpose. The aim of this study was to determine the validity and reliability of the Turkish version of the Job Performance Instrument. This study used a methodological design and a sample of 240 nurses working at different units in four hospitals in Istanbul, Turkey. A descriptive data form, the Job Performance Scale, and the Employee Performance Scale were used to collect data. Data were analyzed using IBM SPSS Statistics Version 21.0 and LISREL Version 8.51. On the basis of the data analysis, the instrument was revised. Some items were deleted, and subscales were combined. The Turkish version of the Job Performance Instrument was determined to be valid and reliable to measure the performance of nurses. The instrument is suitable for evaluating current nursing roles.

  16. Estimating Parameters for the PVsyst Version 6 Photovoltaic Module Performance Model

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Clifford [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-10-01

    We present an algorithm to determine parameters for the photovoltaic module perf ormance model encoded in the software package PVsyst(TM) version 6. Our method operates on current - voltage (I - V) measured over a range of irradiance and temperature conditions. We describe the method and illustrate its steps using data for a 36 cell crystalli ne silicon module. We qualitatively compare our method with one other technique for estimating parameters for the PVsyst(TM) version 6 model .

  17. How to Maintain Computerized Procedure System in the same Version

    International Nuclear Information System (INIS)

    Jung, Yeon Sub

    2016-01-01

    CPS(Computerized Procedure System) has been introduced in advanced nuclear power plant worldwide. Korean CPS complies with this trend. It has been applied to Shinkori3,4 and all their successors including BNPP1,2,3,4. CPS is designed by KHNP CRI, and developed by Westinghouse or Doosan. Initial design has been improved by reflecting operator experience, human factor V and V, and advanced engineering method. Design improvement makes CPS differ from plant to plant. For example CPS in Shinhanul cannot interpret CP(Computerized Procedure) of ShinKori3, 4. Different CPS makes it difficult to utilize CP and train operators. Therefore it is important to keep CPS in single version. Note that typical text editors in the office are kept in single version. On the other hand, plant monitoring systems in main control room are actually different. Because CPS is positioned between text editor and monitoring system, goal to maintain CPS in single version is not an easy task. From Shinkori3,4, lots of improvements are achieved in CPS. This improvement surely makes operation easy and will not introduce human errors. Side effect of improvement is that PXS and CPS ES may not be compatible among nuclear power plants. So the side effect should be avoided by minimizing change of XML. Initial XML had been developed for Shinkori3,4. The XML has been modified slightly for Shinhanul1,2. PXS and CPS ES are being developed for the same version for all nuclear power plants of APR1400

  18. NOAA Climate Data Record (CDR) of SSM/I and SSMIS Microwave Brightness Temperatures, RSS Version 6 (Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note: this dataset has been superseded by a newer version (see below). This version is archived offline by NOAA NCEI. Users should not obtain this version...

  19. Global Fertilizer and Manure, Version 1: Nitrogen Fertilizer Application

    Data.gov (United States)

    National Aeronautics and Space Administration — The Nitrogen Fertilizer Application dataset of the Global Fertilizer and Manure, Version 1 Data Collection represents the amount of nitrogen fertilizer nutrients...

  20. Global Fertilizer and Manure, Version 1: Phosphorus Fertilizer Application

    Data.gov (United States)

    National Aeronautics and Space Administration — The Phosphorus Fertilizer Application dataset of the Global Fertilizer and Manure, Version 1 Data Collection represents the amount of phosphorus fertilizer nutrients...

  1. Validity of the Severe Impairment Battery Short Version.

    NARCIS (Netherlands)

    Jonghe, J.F. de; Wetzels, R.B.; Mulders, A.; Zuidema, S.U.; Koopmans, R.T.C.M.

    2009-01-01

    BACKGROUND: Efficient neuropsychological tests are needed to measure cognitive impairment in moderate to severe dementia. OBJECTIVE: To examine construct validity of the Severe Impairment Battery Short Version (SIB-S) in nursing home patients with moderate to severe dementia, and to examine

  2. PC/FRAM, Version 3.2 User Manual

    International Nuclear Information System (INIS)

    Kelley, T.A.; Sampson, T.E.

    1999-01-01

    This manual describes the use of version 3.2 of the PC/FRAM plutonium isotopic analysis software developed in the Safeguards Science and Technology Group, NE-5, Nonproliferation and International Security Division Los Alamos National Laboratory. The software analyzes the gamma ray spectrum from plutonium-bearing items and determines the isotopic distribution of the plutonium 241Am content and concentration of other isotopes in the item. The software can also determine the isotopic distribution of uranium isotopes in items containing only uranium. The body of this manual descenies the generic version of the code. Special facility-specific enhancements, if they apply, will be described in the appendices. The information in this manual applies equally well to version 3.3, which has been licensed to ORTEC. The software can analyze data that is stored in a file on disk. It understands several storage formats including Canberra's S1OO format, ORTEC'S 'chn' and 'SPC' formats, and several ASCII text formats. The software can also control data acquisition using an MCA and then store the results in a file on disk for later analysis or analyze the spectrum directly after the acquisition. The software currently only supports the control of ORTEC MCB'S. Support for Canbema's Genie-2000 Spectroscopy Systems will be added in the future. Support for reading and writing CAM files will also be forthcoming. A versatile parameter fde database structure governs all facets of the data analysis. User editing of the parameter sets allows great flexibility in handling data with different isotopic distributions, interfering isotopes, and different acquisition parameters such as energy calibration, and detector type. This manual is intended for the system supervisor or the local user who is to be the resident expert. Excerpts from this manual may also be appropriate for the system operator who will routinely use the instrument

  3. DOE-2 supplement: Version 2.1E

    Energy Technology Data Exchange (ETDEWEB)

    Winkelmann, F.C.; Birdsall, B.E.; Buhl, W.F.; Ellington, K.L.; Erdem, A.E. [Lawrence Berkeley Lab., CA (United States); Hirsch, J.J.; Gates, S. [Hirsch (James J.) and Associates, Camarillo, CA (United States)

    1993-11-01

    This publication updates the DOE-2 Supplement form version 2.1D to version to 2.1E. It contains detailed discussions and instructions for using the features and enhancements introduced into the 2.1B, 2.1C, 2.1D, and 2.1E versions of the program. The building description section contains information on input functions in loads and systems, hourly report frequencies, saving files of hourly output for post processing, sharing hourly report data among program modules, the metric option, and input macros and general library features. The loads section contains information on sunspaces, sunspace modeling, window management and solar radiation, daylighting, trombe walls, fixed shades, fins and overhangs, shade schedules, self shades, heat distribution from lights, the Sherman-Grimsrud infiltrations method. terrain and height modification to wind speed, floor multipliers and interior wall types, improved exterior infrared radiation loss calculation, improved outside air film conductance calculation, window library, window frames, and switchable glazing. The systems section contains information on energy end use and meters, powered induction units, a packaged variable volume -- variable temperature system, a residential variable volume -- variable temperature system, air source heat pump enhancements, water loop heat pump enhancements, variable speed electric heat pump, gas heat pumps, hot water heaters, evaporative cooling, total gas solid-desiccant systems, add on desiccant cooling, water cooled condensers, evaporative precoolers outside air economizer control, optimum fan start, heat recovery from refrigerated case work, night ventilation, baseboard heating, moisture balance calculations, a residential natural ventilation algorithm, improved cooling coil model, system sizing and independent cooling and heating sizing ratios. The plant section contains information on energy meters, gas fired absorption chillers, engine driven compressor chillers, and ice energy storage.

  4. Reliability and validity of the Korean version of Pediatric Voice Handicap Index: in school age children.

    Science.gov (United States)

    Park, Sung Shin; Kwon, Tack-Kyun; Choi, Seong Hee; Lee, Won Yong; Hong, Young Hye; Jeong, Nyun Gi; Sung, Myung-Whun; Kim, Kwang Hyun

    2013-01-01

    The aim of this study was to assess the reliability and validity of the Pediatric Voice Handicap Index (pVHI) for cross-cultural adaptation of the Korean version with school age children. The questionnaire was translated into Korean and was completed by 101 Korean parents who have children with or without disordered voice. The Korean version-pVHI scores were obtained with 60 parents of normal children and 41 parents who have children with voice problems. Content validity was verified by five experienced speech-language pathologists with clinical specialization in voice disorders. Internal consistency was calculated through Cronbach's α coefficient and test-retest reliability of the Korean version-pVHI score was determined using Pearson product-moment correlation coefficients. Mann-Whitney U test was used to compare GRBAS with the Korean version-pVHI scores between normal and dysphonia group. The relationship between the parent-reported the Korean version-pVHI total scores and perceptual ratings of voice quality from experts was investigated using Spearman correlation coefficients. The results showed that the Korean version-pVHI provided a high internal consistency (α=0.92) and test-retest reliability of its subscales: total (T) 0.97, functional (F) 0.90, physical (P) 0.95, emotional (E) 0.92. The Korean version-pVHI mean scores in normal group were 1.28 (T), 0.62 (F), 0.35 (P) and 0.32 (E), respectively whereas those of the Korean version-pVHI in children group with dysphonia were 23.13 (T), 8.90 (F), 9.54 (P) and 4.93 (E). Significant differences in the Korean version-pVHI (T, F, P, E) and perceptual evaluation (grade, rough, breathy) between normal and dysphonia group were revealed (PKorean version-pVHI parameters (T) and perceptual measures (G) was exhibited in children with dysphonia. The subjective Korean version-pVHI can be applicable and useful supplementary tool for evaluating parents' perception of their children's voice dysfunction, identifying

  5. 48 CFR 52.225-14 - Inconsistency between English Version and Translation of Contract.

    Science.gov (United States)

    2010-10-01

    ... English Version and Translation of Contract. 52.225-14 Section 52.225-14 Federal Acquisition Regulations... CLAUSES Text of Provisions and Clauses 52.225-14 Inconsistency between English Version and Translation of... and Translation of Contract (FEB 2000) In the event of inconsistency between any terms of this...

  6. 21 CFR 801.16 - Medical devices; Spanish-language version of certain required statements.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices; Spanish-language version of....16 Medical devices; Spanish-language version of certain required statements. If devices restricted to prescription use only are labeled solely in Spanish for distribution in the Commonwealth of Puerto Rico where...

  7. Responsiveness and sensitivity of the Stroke Specific Quality of Life Scale Danish version

    DEFF Research Database (Denmark)

    Muus, Ingrid; Christensen, Doris; Petzold, Max

    2011-01-01

    To test responsiveness and sensitivity to change of the Stroke Specific Quality of Life Scale Danish version (SSQOL-DK) scores in patients following stroke.......To test responsiveness and sensitivity to change of the Stroke Specific Quality of Life Scale Danish version (SSQOL-DK) scores in patients following stroke....

  8. JaSTA-2: Second version of the Java Superposition T-matrix Application

    Science.gov (United States)

    Halder, Prithish; Das, Himadri Sekhar

    2017-12-01

    In this article, we announce the development of a new version of the Java Superposition T-matrix App (JaSTA-2), to study the light scattering properties of porous aggregate particles. It has been developed using Netbeans 7.1.2, which is a java integrated development environment (IDE). The JaSTA uses double precision superposition T-matrix codes for multi-sphere clusters in random orientation, developed by Mackowski and Mischenko (1996). The new version consists of two options as part of the input parameters: (i) single wavelength and (ii) multiple wavelengths. The first option (which retains the applicability of older version of JaSTA) calculates the light scattering properties of aggregates of spheres for a single wavelength at a given instant of time whereas the second option can execute the code for a multiple numbers of wavelengths in a single run. JaSTA-2 provides convenient and quicker data analysis which can be used in diverse fields like Planetary Science, Atmospheric Physics, Nanoscience, etc. This version of the software is developed for Linux platform only, and it can be operated over all the cores of a processor using the multi-threading option.

  9. NOAA Climate Data Record (CDR) of Passive Microwave Sea Ice Concentration, Version 1.0

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset version has been superseded by version 2. This data set provides a Climate Data Record (CDR) of passive microwave sea ice concentration based on the...

  10. Development of the Thai version of Mini-Cog, a brief cognitive screening test.

    Science.gov (United States)

    Trongsakul, Supaporn; Lambert, Rod; Clark, Allan; Wongpakaran, Nahathai; Cross, Jane

    2015-05-01

    Cognitive impairment, such as dementia, has emerged as the leading public health problem among the elderly. Therefore, early detection of the disorder and providing appropriate healthcare and management is important, particularly, for the patients with comorbid diabetes who require long-term treatment strategies. In Thailand, because of a large number of elderly patients with diabetes, and time constraints in primary care settings, a short and effective cognitive screening test is required. The Mini-Cog is a short and valid cognitive screening test that was specifically designed for use in primary care settings. The present study translated the English language version into a Thai language version, and then measured the interrater reliability and concurrent validity. The processes of cross-language translation were carried out to develop a Thai language version of the Mini-Cog. A total of 21 Thai older adults with type 2 diabetes with a mean aged of 69 ± 7 years were recruited into a study investigating the interrater reliability and concurrent validity of the Mini-Cog Thai version in one primary care center in Thailand. The Mini-Cog Thai version showed a good interrater reliability (K = 0.80, P validity (r = 0.47, P = 0.007, 95% CI 0.37,0.55) with the Mini-Mental State Examination Thai 2002. The findings show that the Thai version of the Mini-Cog is a reliable, performance-based tool in the screening for cognitive function in primary care settings in Thailand. It is recommended that it could be used as a new cognitive screening test for the aging population in the Thai community. © 2014 Japan Geriatrics Society.

  11. Using the Hemophilia Joint Health Score for assessment of children: Reliability of the Spanish version.

    Science.gov (United States)

    R, Cuesta-Barriuso; A, Torres-Ortuño; S, Pérez-Alenda; J, Carrasco Juan; F, Querol; J, Nieto-Munuera; Ja, López-Pina

    2018-02-27

    Numerous measuring instruments for the evaluation of hemophilic arthropathy have been developed. One of the most used systems is the Hemophilia Joint Health Score (HJHS) given its sensitivity to clinical changes appearing in the joints because of recurrent hemarthrosis. Assessing the interrater reliability, using the Spanish version of the HJHS (version 2.1) in children with hemophilia. Reliability study to assess the interrater reliability of the Spanish version of HJHS. A sample of 36 children aged 7-13 years diagnosed with hemophilia A or B was used. Two physiotherapists performed physical assessments with the Spanish version of the HJHS. Descriptive statistics (range, mean, standard deviation) and the analysis of interrater reliability were calculated. The interrater reliability was heterogeneous since the Kappa coefficient range (ĸ), although significant (p reliability of the Spanish population version of the HJHS is high. This scale should be used generically in evaluating musculoskeletal pediatric patients with hemophilia.

  12. Reflections on the nature of genius: on the 300th anniversary of Mikhail Lomonosov (1711-1765)

    International Nuclear Information System (INIS)

    Shiltsev, V

    2012-01-01

    This presentation goes beyond celebratory narration of the life and scientific achievements of Russia's first modern scientist Mikhail Vasilievich Lomonosov (1711-1765). Coming from the notion of complexity of sciences, we introduce 'a genius formula' G=TBD for semi-qualitative evaluation of a person's impact on the society, distinguish two type of geniuses, give several examples and draw general conclusions. The work largely follows presentation at the Fermilab Colloquium in November of 2011. (author)

  13. [External cephalic version after 36th week of gestationAnalysis of women´s perspective].

    Science.gov (United States)

    Wágnerová, K; Hruban, L; Janků, P

    2017-01-01

    Evaluation of opinions and subjective feelings of patients who have undergone an external cephalic version of a fetus in breech presentation after the 36th week of pregnancy. Observational analytic cohort study. Department of Obstetrics and Gynecology, Masaryk University, University Hospital Brno. We collected opinions and subjective evaluation from pregnant women who underwent an attempt of external cephalic version at the department of Gynecology and Obstetrics, Masaryk University in Brno in the period from 1st January 2015 to 31st December 2016 through a questionnaire. The questionnaire contained a total of 10 dichotomous, sampling, enumeration and scale questions. Questions were focused on the source and type of information on external cephalic version, expectations of the patients, evaluation of pain and feelings during the procedure and the overall impression. We also evaluated the differences between answers from patients after a successful and an unsuccessful version. In reported period 205 pregnant women underwent an attempt of external cephalic version. Procedure was successful in 105 (51.2%) cases of which 81 (77.1%) subsequently gave birth vaginally, 24 (22.9%) delivered by caesarean section, 10 (9.5%) out of all patients delivered in other hospitals. The total number of fully completed questionnaires was 187 (after a successful version 98 and 89 after an unsuccessful version). The most common source of information about the procedure was given to the patients from their gynecologists (40.5%) and doctors at the ambulance in the hospital where the patients are sent before delivery by their gynecologists (27.9%). Most mothers received mostly positive information (70.5%) - increased likelihood of vaginal delivery, high success rate, low risk to mother and child. Attitude of the gynecologists on the external cephalic version was positive in 52.6% and they recommended it. 14.4% of the patients had no fear before the procedure, 61% patients were nervous and

  14. Validity of the Mayer-Salovey-Caruso Emotional Intelligence Test: Youth Version-Research Edition

    Science.gov (United States)

    Peters, Christine; Kranzler, John H.; Rossen, Eric

    2009-01-01

    This study examines the criterion-related validity evidence of scores on the Mayer-Salovey-Caruso Emotional Intelligence Test: Youth Version-Research Version. The authors also investigate the relationship between scores on the MSCEIT-YV and chronological age. Results provide initial support for the construct validity of the MSCEIT-YV but also…

  15. PR-EDB: Power Reactor Embrittlement Database Version 3

    International Nuclear Information System (INIS)

    Wang, Jy-An John; Subramani, Ranjit

    2008-01-01

    The aging and degradation of light-water reactor pressure vessels is of particular concern because of their relevance to plant integrity and the magnitude of the expected irradiation embrittlement. The radiation embrittlement of reactor pressure vessel materials depends on many factors, such as neutron fluence, flux, and energy spectrum, irradiation temperature, and preirradiation material history and chemical compositions. These factors must be considered to reliably predict pressure vessel embrittlement and to ensure the safe operation of the reactor. Large amounts of data from surveillance capsules are needed to develop a generally applicable damage prediction model that can be used for industry standards and regulatory guides. Furthermore, the investigations of regulatory issues such as vessel integrity over plant life, vessel failure, and sufficiency of current codes, Standard Review Plans (SRPs), and Guides for license renewal can be greatly expedited by the use of a well-designed computerized database. The Power Reactor Embrittlement Database (PR-EDB) is such a comprehensive collection of data for U.S. designed commercial nuclear reactors. The current version of the PR-EDB lists the test results of 104 heat-affected-zone (HAZ) materials, 115 weld materials, and 141 base materials, including 103 plates, 35 forgings, and 3 correlation monitor materials that were irradiated in 321 capsules from 106 commercial power reactors. The data files are given in dBASE format and can be accessed with any personal computer using the Windows operating system. 'User-friendly' utility programs have been written to investigate radiation embrittlement using this database. Utility programs allow the user to retrieve, select and manipulate specific data, display data to the screen or printer, and fit and plot Charpy impact data. The PR-EDB Version 3.0 upgrades Version 2.0. The package was developed based on the Microsoft .NET framework technology and uses Microsoft Access for

  16. PR-EDB: Power Reactor Embrittlement Database - Version 3

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [ORNL; Subramani, Ranjit [ORNL

    2008-03-01

    The aging and degradation of light-water reactor pressure vessels is of particular concern because of their relevance to plant integrity and the magnitude of the expected irradiation embrittlement. The radiation embrittlement of reactor pressure vessel materials depends on many factors, such as neutron fluence, flux, and energy spectrum, irradiation temperature, and preirradiation material history and chemical compositions. These factors must be considered to reliably predict pressure vessel embrittlement and to ensure the safe operation of the reactor. Large amounts of data from surveillance capsules are needed to develop a generally applicable damage prediction model that can be used for industry standards and regulatory guides. Furthermore, the investigations of regulatory issues such as vessel integrity over plant life, vessel failure, and sufficiency of current codes, Standard Review Plans (SRPs), and Guides for license renewal can be greatly expedited by the use of a well-designed computerized database. The Power Reactor Embrittlement Database (PR-EDB) is such a comprehensive collection of data for U.S. designed commercial nuclear reactors. The current version of the PR-EDB lists the test results of 104 heat-affected-zone (HAZ) materials, 115 weld materials, and 141 base materials, including 103 plates, 35 forgings, and 3 correlation monitor materials that were irradiated in 321 capsules from 106 commercial power reactors. The data files are given in dBASE format and can be accessed with any personal computer using the Windows operating system. "User-friendly" utility programs have been written to investigate radiation embrittlement using this database. Utility programs allow the user to retrieve, select and manipulate specific data, display data to the screen or printer, and fit and plot Charpy impact data. The PR-EDB Version 3.0 upgrades Version 2.0. The package was developed based on the Microsoft .NET framework technology and uses Microsoft Access for

  17. Catquest-9SF questionnaire: validation of Malay and Chinese-language versions using Rasch analysis.

    Science.gov (United States)

    Adnan, Tassha Hilda; Mohamed Apandi, Mokhlisoh; Kamaruddin, Haireen; Salowi, Mohamad Aziz; Law, Kian Boon; Haniff, Jamaiyah; Goh, Pik Pin

    2018-01-05

    Catquest questionnaire was originally developed in Swedish to measure patients' self-assessed visual function to evaluate the benefit of cataract surgery. The result of the Rasch analysis leading to the creation of the nine-item short form of Catquest, (Catquest-9SF), and it had been translated and validated in English. The aim is therefore to evaluate the translated Catquest-9SF questionnaire in Malay and Chinese (Mandarin) language version for measuring patient-reported visual function among cataract population in Malaysia. The English version of Catquest-9SF questionnaire was translated and back translated into Malay and Chinese languages. The Malay and Chinese translated versions were self-administered by 236 and 202 pre-operative patients drawn from a cataract surgery waiting list, respectively. The translated Catquest-9SF data and its four response options were assessed for fit to the Rasch model. The Catquest-9SF performed well in the Malay and Chinese translated versions fulfilling all criteria for valid measurement, as demonstrated by Rasch analysis. Both versions of questionnaire had ordered response thresholds, with a good person separation (Malay 2.84; and Chinese 2.59) and patient separation reliability (Malay 0.89; Chinese 0.87). Targeting was 0.30 and -0.11 logits in Malay and Chinese versions respectively, indicating that the item difficulty was well suited to the visual abilities of the patients. All items fit a single overall construct (Malay infit range 0.85-1.26, outfit range 0.73-1.13; Chinese infit range 0.80-1.51, outfit range 0.71-1.36), unidimensional by principal components analysis, and was free of Differential Item Functioning (DIF). These results support the good overall functioning of the Catquest-9SF in patients with cataract. The translated questionnaire to Malay and Chinese-language versions are reliable and valid in measuring visual disability outcomes in the Malaysian cataract population.

  18. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    Energy Technology Data Exchange (ETDEWEB)

    Nitschke, Ashley [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology, Aurora, CO (United States); Lambert, Jeffery R. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); Glueck, Deborah H. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); University of Colorado School of Medicine, University of Colorado Denver, Department of Radiology, Aurora, CO (United States); Jesse, Mary Kristen; Strickland, Colin [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Mei-Dan, Omer [University of Colorado School of Medicine, University of Colorado Denver, Division of Sports Medicine and Hip Preservation, Department of Orthopaedics, Aurora, CO (United States); Petersen, Brian [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Inland Imaging, Division of Musculoskeletal Radiology, Spokane, WA (United States)

    2015-11-15

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  19. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    International Nuclear Information System (INIS)

    Nitschke, Ashley; Lambert, Jeffery R.; Glueck, Deborah H.; Jesse, Mary Kristen; Strickland, Colin; Mei-Dan, Omer; Petersen, Brian

    2015-01-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  20. Global Historical Climatology Network - Daily (GHCN-Daily), Version 3

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Global Historical Climatology Network - Daily (GHCN-Daily) dataset integrates daily climate observations from approximately 30 different data sources. Version 3...

  1. Development, equivalence study, and normative data of version B of the Spanish-language Free and Cued Selective Reminding Test.

    Science.gov (United States)

    Grau-Guinea, L; Pérez-Enríquez, C; García-Escobar, G; Arrondo-Elizarán, C; Pereira-Cutiño, B; Florido-Santiago, M; Piqué-Candini, J; Planas, A; Paez, M; Peña-Casanova, J; Sánchez-Benavides, G

    2018-05-08

    The Free and Cued Selective Reminding Test (FCSRT) is widely used for the assessment of verbal episodic memory, mainly in patients with Alzheimer disease. A Spanish version of the FCSRT and normative data were developed within the NEURONORMA project. Availability of alternative, equivalent versions is useful for following patients up in clinical settings. This study aimed to develop an alternative version of the original FCSRT (version B) and to study its equivalence to the original Spanish test (version A), and its performance in a sample of healthy individuals, in order to develop reference data. We evaluated 232 healthy participants of the NEURONORMA-Plus project, aged between 18 and 90. Thirty-three participants were assessed with both versions using a counterbalanced design. High intra-class correlation coefficients (between 0.8 and 0.9) were observed in the equivalence study. While no significant differences in performance were observed in total recall scores, free recall scores were significantly lower for version B. These preliminary results suggest that the newly developed FCSRT version B is equivalent to version A in the main variables tested. Further studies are necessary to ensure interchangeability between versions. We provide normative data for the new version. Copyright © 2018 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. External cephalic version-related risks: a meta-analysis

    NARCIS (Netherlands)

    Grootscholten, K.; Kok, M.; Oei, S.G.; Mol, B.W.J.; Post, van der J.A.

    2008-01-01

    OBJECTIVE: To systematically review the literature on external cephalic version–related complications and to assess if the outcome of a version attempt is related to complications. DATA SOURCES: In March 2007 we searched MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials.

  3. IDC Use Case Model Survey Version 1.0.

    Energy Technology Data Exchange (ETDEWEB)

    Carr, Dorthe B.; Harris, James M.

    2014-12-01

    This document contains the brief descriptions for the actors and use cases contained in the IDC Use Case Model Survey. REVISIONS Version Date Author/Team Revision Description Authorized by V1.0 12/2014 IDC Re- engineering Project Team Initial delivery M. Harris

  4. Stress analysis for robot arm version 2

    International Nuclear Information System (INIS)

    Anwar Abdul Rahman; Fikri, A.; Salleh, M. S.; Mohd Arif Hamzah; Azraf Azman; Rosli Darmawan; Mohd Rizal Mamat

    2010-01-01

    The design of a robot needs to be analyzed to ensure the specification and requirement by the user is full filled. Therefore, stress analysis has been performed on the robot arm version 2 after its complete fabrication. This paper discusses the result of the analysis and proposed measures to improve the future design of robot arm. (author)

  5. Original article Validation of the Polish version of the Collective Self-Esteem Scale

    Directory of Open Access Journals (Sweden)

    Róża Bazińska

    2015-07-01

    Full Text Available Background The aim of this article is to present research on the validity and reliability of the Collective Self-Esteem Scale (CSES for the Polish population. The CSES is a measure of individual differences in collective self-esteem, understood as the global evaluation of one’s own social (collective identity. Participants and procedure Participants from two samples (n = 466 and n = 1,009 completed a paper-pencil set of questionnaires which contained the CSES and the Rosenberg Self-Esteem Scale (RSES, and subsets of participants completed scales related to a sense of belonging, well-being and psychological distress (anxiety and depression. Results Like the original version, the Polish version of the CSES comprises 16 items which form the four dimensions of collective self-esteem: Public collective self-esteem, Private collective self-esteem, Membership esteem and Importance of Identity. The results confirm the four-factor structure of the Polish version of the CSES, support the whole Polish version of the CSES as well as its subscales, which represent satisfactory reliability and stability, and provide initial evidence of construct validity. Conclusions As the results of the study indicate, the Polish version of the CSES is a valid and reliable self-report measure for assessing the global self-esteem derived from membership of a group and has proved to be useful in the Polish context.

  6. CALIPSO lidar calibration at 532 nm: version 4 nighttime algorithm

    Directory of Open Access Journals (Sweden)

    J. Kar

    2018-03-01

    Full Text Available Data products from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP on board Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO were recently updated following the implementation of new (version 4 calibration algorithms for all of the Level 1 attenuated backscatter measurements. In this work we present the motivation for and the implementation of the version 4 nighttime 532 nm parallel channel calibration. The nighttime 532 nm calibration is the most fundamental calibration of CALIOP data, since all of CALIOP's other radiometric calibration procedures – i.e., the 532 nm daytime calibration and the 1064 nm calibrations during both nighttime and daytime – depend either directly or indirectly on the 532 nm nighttime calibration. The accuracy of the 532 nm nighttime calibration has been significantly improved by raising the molecular normalization altitude from 30–34 km to the upper possible signal acquisition range of 36–39 km to substantially reduce stratospheric aerosol contamination. Due to the greatly reduced molecular number density and consequently reduced signal-to-noise ratio (SNR at these higher altitudes, the signal is now averaged over a larger number of samples using data from multiple adjacent granules. Additionally, an enhanced strategy for filtering the radiation-induced noise from high-energy particles was adopted. Further, the meteorological model used in the earlier versions has been replaced by the improved Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2, model. An aerosol scattering ratio of 1.01 ± 0.01 is now explicitly used for the calibration altitude. These modifications lead to globally revised calibration coefficients which are, on average, 2–3 % lower than in previous data releases. Further, the new calibration procedure is shown to eliminate biases at high altitudes that were present in earlier versions and

  7. Stability of excess demand functions with respect to a strong version of Wald's axiom

    International Nuclear Information System (INIS)

    An, P.T.; Binh, V.T.T.

    2005-04-01

    In this paper, a strong version of Wald's Axiom of excess demand functions Z : P is part of R >0 n → R n is introduced, namely 'there exists σ > 0 such that p,q is part of P,q T Z(p) - δ ≥ 0, vertical bar δ vertical bar T Z(p) + δ > 0''. We show that Z satisfies the strong version of Wald's Axiom iff -Z is a s-quasimonotone function. Consequently, an excess demand function Z satisfies the strong version of Wald's Axiom iff -Z is stable with respect to the pseudomonotonicity (i.e., there exists ε > 0 such that -Z + a fulfills the pseudomonotonicity for all a is part of R n satisfying parallel a parallel < ε). Some properties on the measure of the strong version of Wald's Axiom of excess demand functions are presented. (author)

  8. The Neuropsychiatric Inventory--NPI. Validation of the Danish version

    DEFF Research Database (Denmark)

    Korner, A.; Lauritzen, Lotte; Lolk, A.

    2008-01-01

    NPI and NPI-VAS were high; only two domains had coefficients below 0.60: depression and agitation/aggression. NPI-total scores increase with increasing severity of dementia. The NPI did not fulfil the scalability assessed by the Mokken and Loevinger coefficients. The NPI Danish version is valid......Assessment of neuropsychiatric symptoms in dementia has great clinical importance. The aim of the study was validation of the Danish version of the NPI, using assessments of 72 demented and 29 non-demented of age 65+ years and their caregivers at three visits. The NPI was administered by the same...... and reliable in assessing neuropsychiatric symptoms in dementia but not fully scalable. The use of single item scores and not total sum score is recommended Udgivelsesdato: 2008...

  9. The second version of the Copenhagen Psychosocial Questionnaire

    DEFF Research Database (Denmark)

    Pejtersen, Jan Hyld; Kristensen, Tage Søndergård; Borg, Vilhelm

    2010-01-01

    AIMS: The aim of the present paper is to present the development of the second version of the Copenhagen Psychosocial Questionnaire (COPSOQ II). METHODS: The development of COPSOQ II took place in five main steps: (1) We considered practical experience from the use of COPSOQ I, in particular...... feedback from workplace studies where the questionnaire had been used; (2) All scales concerning workplace factors in COPSOQ I were analyzed for differential item functioning (DIF) with regard to gender, age and occupational status; (3) A test version of COPSOQ II including new scales and items...... was developed and tested in a representative sample of working Danes between 20 and 59 years of age. In all, 3,517 Danish employees participated in the study. The overall response rate was 60.4%; (4) Based on psychometric analyses, the final questionnaire was developed; and (5) Criteria-related validity...

  10. EPDL97: the evaluated photon data library, '97 version. Summary documentation

    International Nuclear Information System (INIS)

    Pronyaev, V.G.; McLaughlin, P.

    1998-01-01

    The Evaluated Photon Data Library, 1997 version (EPDL97), is designed for use in photon transport calculations at Lawrence Livermore National Laboratory. This library includes photon interaction data for all elements with atomic number between Z = 1 (hydrogen) and 100 (fermium), including: photoionization, photoexcitation, coherent and incoherent scattering, and pair and triplet production cross sections. For use in applications data is provided for all elements over the energy range 1 eV to 100 GeV. EPDL97 completely supersedes the earlier 1989 version of EPDL(89) (see IAEA-NDS-158, Summary documentation to the EPDL) and it is highly recommended that users only use the most recent version of this library. The Evaluated Atomic Data Library (EADL), Evaluated Electron Data Library (EEDL) an Evaluated Excitation Data Library (EXDL) are included to allow consistent coupled photon-electron transport calculations. The data package is available from the IAEA Nuclear Data Section on CD-ROM (12 files, 74.2 MB). (author)

  11. Measuring Engagement at Work: Validation of the Chinese Version of the Utrecht Work Engagement Scale

    OpenAIRE

    Ng, Sm; Fong, TCt

    2011-01-01

    Background: Work engagement is a positive work-related state of fulfillment characterized by vigor, dedication, and absorption. Previous studies have operationalized the construct through development of the Utrecht Work Engagement Scale. Apart from the original three-factor 17-item version of the instrument (UWES-17), there exists a nine-item shortened revised version (UWES-9). Purpose: The current study explored the psychometric properties of the Chinese version of the Utrecht Work Engagemen...

  12. Measuring Engagement at Work: Validation of the Chinese Version of the Utrecht Work Engagement Scale

    OpenAIRE

    Fong, Ted Chun-tat; Ng, Siu-man

    2011-01-01

    Background Work engagement is a positive work-related state of fulfillment characterized by vigor, dedication, and absorption. Previous studies have operationalized the construct through development of the Utrecht Work Engagement Scale. Apart from the original three-factor 17-item version of the instrument (UWES-17), there exists a nine-item shortened revised version (UWES-9). Purpose The current study explored the psychometric properties of the Chinese version of the Utrecht Work Engagement ...

  13. The EPICS process variable Gateway Version 2

    International Nuclear Information System (INIS)

    Evans, K.

    2005-01-01

    The EPICS Process Variable Gateway is both a Channel Access Server and Channel Access Client that provides a means for many clients, typically on different subnets, to access a process variable while making only one connection to the server that owns the process variable. It also provides additional access security beyond that implemented on the server. It thus protects critical servers while providing suitably restricted access to needed process variables. The original version of the Gateway worked with EPICS Base 3.13 but required a special version, since the changes necessary for its operation were never incorporated into EPICS Base. Version 2 works with any standard EPICS Base 3.14.6 or later and has many improvements in both performance and features over the older version. The Gateway is now used at many institutions and has become a stable, high-performance application. It is capable of handling tens of thousands of process variables with hundreds of thousands of events per second. It has run for over three months in a production environment without having to be restarted. It has many internal process variables that can be used to monitor its state using standard EPICS client tools, such as MEDM and StripTool. Other internal process variables can be used to stop the Gateway, make several kinds of reports, or change the access security without stopping the Gateway. It can even be started on remote workstations from MEDM by using a Secure Shell script. This paper will describe the new Gateway and how it is used. The Gateway is both a server (like an EPICS Input/Output Controller (IOC)) and a client (like the EPICS Motif Editor and Display Manager (MEDM), StripTool, and others). Clients connect to the server side, and the client side connects to IOCs and other servers, possibly other Gateways. See Fig. 1. There are perhaps three principal reasons for using the Gateway: (1) it allows many clients to access a process variable while making only one connection to

  14. Guideline for radioiodine therapy for benign thyroid diseases (version 3)

    Energy Technology Data Exchange (ETDEWEB)

    Dietlein, M.; Schicha, H. [Klinik und Poliklinik fuer Nuklearmedizin der Univ. zu Koeln (Germany); Dressler, J. [Nuklearmedizinische Klinik der Henriettenstiftung, Hannover (Germany); Gruenwald, F. [Klinik und Poliklinik fuer Nuklearmedizin der Univ. Frankfurt (Germany); Leisner, B. [Abt. fuer Nuklearmedizin des Allg. Krankenhauses St. Georg, Hamburg (Germany); Moser, E. [Abt. fuer Nuklearmedizin der Radiologischen Universitaetsklinik Freiburg (Germany); Reiners, C.; Schneider, P. [Klinik und Poliklinik fuer Nuklearmedizin der Univ. Wuerzburg (Germany); Schober, O. [Klinik und Poliklinik fuer Nuklearmedizin der Univ. Muenster (Germany)

    2004-12-01

    The version 3 of the guideline for radioiodine therapy for benign thyroid diseases presents first of all a revision of the version 2. The chapter indication for radioiodine therapy, surgical treatment or antithyroid drugs bases on an interdisciplinary consensus. The manifold criteria for decision making consider the entity of thyroid disease (autonomy, Graves' disease, goitre, goitre recurrence), the thyroid volume, suspicion of malignancy, cystic nodules, risk of surgery and co-morbidity, history of subtotal thyroidectomy, persistent or recurrent thyrotoxicosis caused by Graves' disease including known risk factors for relapse, compression of the trachea caused by goitre, requirement of direct therapeutic effect as well as the patient's preference. Because often some of these criteria are relevant, the guideline offers the necessary flexibility for individual decisions. Further topics are patients' preparation, counseling, dosage concepts, procedural details, results, side effects and follow-up care. The prophylactic use of glucocorticoids during radioiodine therapy in patients without preexisting ophthalmopathy as well as dosage and duration of glucocorticoid medication in patients with preexisting ophthalmopathy need to be clarified in further studies. The pragmatic recommendations for the combined use of radioiodine and glucocorticoids remained unchanged in the 3{sup rd} version. (orig.) [German] Die Version 3 der Leitlinie zur Radioiodtherapie (RIT) bei benignen Schilddruesenerkrankungen stellt im Wesentlichen eine redaktionelle Ueberarbeitung der Version 2 dar. Im Kapitel Indikation und Empfehlungen fuer eine Radioiodtherapie, eine Operation oder eine thyreostatische Therapie bei gutartigen Schilddruesenerkrankungen basiert die Leitlinie auf einem interdisziplinaer abgestimmten Konzept. Die Entscheidungskriterien sind multifaktoriell und beruecksichtigen die Art der Schilddruesenerkrankung (Autonomie, Morbus Basedow, Struma, Rezidivstruma

  15. Requirement analysis and sensor specifications – First version

    NARCIS (Netherlands)

    Sharma, Puneet; Wild, Fridolin; Klemke, Roland; Helin, Kaj; Azam, Tre

    2017-01-01

    In this first version of the deliverable, we make the following contributions: to design the WEKIT capturing platform and the associated experience capturing API, we use a methodology for system engineering that is relevant for different domains such as: aviation, space, and medical and different

  16. UPC Language and Library Specifications, Version 1.3

    Energy Technology Data Exchange (ETDEWEB)

    UPC Consortium; Bonachea, Dan; Funck, Gary

    2013-11-16

    UPC is an explicitly parallel extension to the ISO C 99 Standard. UPC follows the partitioned global address space programming model. This document is the formal specification for the UPC language and library syntax and semantics, and supersedes prior specification version 1.2 (LBNL-59208).

  17. Remifentanil versus placebo for analgesia during external cephalic version: a randomised clinical trial.

    Science.gov (United States)

    Muñoz, H; Guerra, S; Perez-Vaquero, P; Valero Martinez, C; Aizpuru, F; Lopez-Picado, A

    2014-02-01

    Breech presentation occurs in up to 3% of pregnancies at term and may be an indication for caesarean delivery. External cephalic version can be effective in repositioning the fetus in a cephalic presentation, but may be painful for the mother. Our aim was to assess the efficacy of remifentanil versus placebo for pain relief during external cephalic version. A randomized, double-blind, controlled trial that included women at 36-41 weeks of gestation with non-cephalic presentations was performed. Women were randomized to receive either a remifentanil infusion at 0.1 μg/kg/min and demand boluses of 0.1 μg/kg, or saline placebo. The primary outcome was the numerical rating pain score (0-10) after external cephalic version. Sixty women were recruited, 29 in the control group and 31 in the remifentanil group. There were significant differences in pain scores at the end of the procedure (control 6.5 ± 2.4 vs. remifentanil 4.7 ± 2.5, P = 0.005) but not 10 min later (P = 0.054). The overall success rate for external cephalic version was 49% with no significant differences between groups (remifentanil group 54.8% vs. control group 41.3%, P = 0.358). In the remifentanil group, there was one case of nausea and vomiting, one of drowsiness and three cases of fetal bradycardia. In the control group, there were three cases of nausea and vomiting, one of dizziness and nine cases of fetal bradycardia. Intravenous remifentanil with bolus doses on demand during external cephalic version achieved a reduction in pain and increased maternal satisfaction. There were no additional adverse effects, and no difference in the success rate of external cephalic version or the incidence of fetal bradycardia. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. VizieR Online Data Catalog: SKY2000 Master Catalog, Version 5 (Myers+ 2006)

    Science.gov (United States)

    Myers, J. R.; Sande, C. B.; Miller, A. C.; Warren, W. H., Jr.; Tracewell, D. A.

    2015-02-01

    The SKYMAP Star Catalog System consists of a Master Catalog stellar database and a collection of utility software designed to create and maintain the database and to generate derivative mission star catalogs (run catalogs). It contains an extensive compilation of information on almost 300000 stars brighter than 8.0mag. The original SKYMAP Master Catalog was generated in the early 1970's. Incremental updates and corrections were made over the following years but the first complete revision of the source data occurred with Version 4.0. This revision also produced a unique, consolidated source of astrometric information which can be used by the astronomical community. The derived quantities were removed and wideband and photometric data in the R (red) and I (infrared) systems were added. Version 4 of the SKY2000 Master Catalog was completed in April 2002; it marks the global replacement of the variability identifier and variability data fields. More details can be found in the description file sky2kv4.pdf. The SKY2000 Version 5 Revision 4 Master Catalog differs from Revision 3 in that MK and HD spectral types have been added from the Catalogue of Stellar Spectral Classifications (B. A. Skiff of Lowell Observatory, 2005), which has been assigned source code 50 in this process. 9622 entries now have MK types from this source, while 3976 entries have HD types from this source. SKY2000 V5 R4 also differs globally from preceding MC versions in that the Galactic coordinate computations performed by UPDATE have been increased in accuracy, so that differences from the same quantities from other sources are now typically in the last decimal places carried in the MC. This version supersedes the previous versions 1(V/95), 2(V/102), 3(V/105) and 4(V/109). (6 data files).

  19. The HARWELL version of the computer code E-DEP-1

    International Nuclear Information System (INIS)

    Matthews, M.D.

    1983-03-01

    This document describes the modified HARWELL version of the computer program EDEP-1 which has been in use on the IBM Central Computer for some years. The program can be used to calculate heavy ion ranges and/or profiles of energy deposited into nuclear processes for a wide variety of ion/target combinations. The initial setting up of this program on the IBM Central Computer has been described in an earlier report. A second report was later issued to bring the first report up to date following changes to this code required to suit the needs of workers at HARWELL. This later report described in particular the provision of new electronic stopping powers and an alternative method for calculating the energy straggle of beam ions with depth in a target. This new report describes further extensions to the electronic stopping powers available in the HARWELL version of this program and, for the first time, gives details of alternative nuclear stopping powers now available. This new document is intended as a reference manual for the use of the HARWELL version of EDEP-1. In this respect this document should be the final report on the status of this program. (author)

  20. Guideline for radioiodine therapy for benign thyroid diseases (version 3)

    International Nuclear Information System (INIS)

    Dietlein, M.; Schicha, H.; Dressler, J.; Gruenwald, F.; Leisner, B.; Moser, E.; Reiners, C.; Schneider, P.; Schober, O.

    2004-01-01

    The version 3 of the guideline for radioiodine therapy for benign thyroid diseases presents first of all a revision of the version 2. The chapter indication for radioiodine therapy, surgical treatment or antithyroid drugs bases on an interdisciplinary consensus. The manifold criteria for decision making consider the entity of thyroid disease (autonomy, Graves' disease, goitre, goitre recurrence), the thyroid volume, suspicion of malignancy, cystic nodules, risk of surgery and co-morbidity, history of subtotal thyroidectomy, persistent or recurrent thyrotoxicosis caused by Graves' disease including known risk factors for relapse, compression of the trachea caused by goitre, requirement of direct therapeutic effect as well as the patient's preference. Because often some of these criteria are relevant, the guideline offers the necessary flexibility for individual decisions. Further topics are patients' preparation, counseling, dosage concepts, procedural details, results, side effects and follow-up care. The prophylactic use of glucocorticoids during radioiodine therapy in patients without preexisting ophthalmopathy as well as dosage and duration of glucocorticoid medication in patients with preexisting ophthalmopathy need to be clarified in further studies. The pragmatic recommendations for the combined use of radioiodine and glucocorticoids remained unchanged in the 3 rd version. (orig.) [de

  1. New Cerec software version 4.3 for Omnicam and Bluecam.

    Science.gov (United States)

    Fritzsche, G; Schenk, O

    2014-01-01

    The introduction of the Cerec Omnicam acquisition unit in September 2012 presented Sirona with a challenge: con- figuring the existing software version 4 for both the exist- ing Bluecam, which uses still images, and the video-based Omnicam. Sirona has succeeded in making all the features introduced in version 4.2 (such as the virtual articulator or implant-supported single-tooth restorations, both monolithic and two-part designs) work with both camera types, without compromising the uniform, homogeneous look and feel of the software. The virtual articulator (Figs 1a to 1c) now has even more individual configuration options and allows the setting of almost all angles derived from the individual transfer bow based on precalculated average values. The new software version 4.3, presented in July 2014, fixes some minor bugs, such as the time-consuming "empty grinding" after necessary water changes during the grinding process, but also includes many features that noticeably ease the workflow. For example, the important scanning precision in the region of the anterior incisal edges has been improved, which makes the scanning process more reliable, faster, and far more comfortable.

  2. Nuclear Engine System Simulation (NESS). Version 2.0: Program user's guide. Final Report

    International Nuclear Information System (INIS)

    Pelaccio, D.G.; Scheil, C.M.; Petrosky, L.

    1993-03-01

    This Program User's Guide discusses the Nuclear Thermal Propulsion (NTP) engine system design features and capabilities modeled in the Nuclear Engine System Simulation (NESS): Version 2.0 program (referred to as NESS throughout the remainder of this document), as well as its operation. NESS was upgraded to include many new modeling capabilities not available in the original version delivered to NASA LeRC in Dec. 1991, NESS's new features include the following: (1) an improved input format; (2) an advanced solid-core NERVA-type reactor system model (ENABLER 2); (3) a bleed-cycle engine system option; (4) an axial-turbopump design option; (5) an automated pump-out turbopump assembly sizing option; (6) an off-design gas generator engine cycle design option; (7) updated hydrogen properties; (8) an improved output formnd (9) personal computer operation capability. Sample design cases are presented in the user's guide that demonstrate many of the new features associated with this upgraded version of NESS, as well as design modeling features associated with the original version of NESS

  3. Physical study of the 'snow flake' version of the reactor EL-3 (1963)

    International Nuclear Information System (INIS)

    Abillon, E.; Genthon, J.P.

    1963-01-01

    A systematic study has been made of the different thermodynamic and neutronic aspects of various versions of the 'snow flake' likely to fulfil the aims which were set out (improvement of the reactivity, of the experimental volume, improvement in the working conditions of EL-3). After this systematic study, a choice was made in principle of one version amongst the several available (solutions using 8 or 10 pencils-various methods of heat transfer: corrugation, cartridges which may or may not be filled with helium... etc., variable enrichments... ). The choice is that of a version which can already at the present be considered as feasible, which represents already a notable improvement of the pile and which does not imply the existence of a major problem as far as the possible change-over later to an improved version is concerned. This choice defines a fuel element and a configuration for the core. A detailed recapitulation has been made of all the research being carried out for the possible solutions in this particular case. (authors) [fr

  4. PC 386-based version of DORT

    International Nuclear Information System (INIS)

    Tanker, E.

    1992-01-01

    Problems encountered during the adaptation of DORT on a personal computer using a Fortran77 compiler are described, modifications done to solve these are explained. Three test cases were run with the modified version and results are compared with those obtained on an IBM 3090/200. Numerical differences were observed in the last three decimal digits of the computations at most. The running times on the PC were found to be satisfactory for these test cases

  5. Prevalence, Outcome, and Women's Experiences of External Cephalic Version in a Low-Risk Population

    NARCIS (Netherlands)

    Rijnders, Marlies; Offerhaus, Pien; van Dommelen, Paula; Wiegers, Therese; Buitendijk, Simone

    2010-01-01

    Background: Until recently, external cephalic version to prevent breech presentation at birth was not widely accepted. The objective of our study was to assess the prevalence, outcomes, and women's experiences of external cephalic version to improve the implementation of the procedure in the

  6. Prevalence, outcome, and women's experiences of external cephalic version in a low-risk population

    NARCIS (Netherlands)

    Rijnders, M.; Offerhaus, P.; Dommelen, P. van; Wiegers, T.; Buitendijk, S.

    2010-01-01

    Background: Until recently, external cephalic version to prevent breech presentation at birth was not widely accepted. The objective of our study was to assess the prevalence, outcomes, and women's experiences of external cephalic version to improve the implementation of the procedure in the

  7. Planetary Mission Entry Vehicles Quick Reference Guide. Version 3.0

    Science.gov (United States)

    Davies, Carol; Arcadi, Marla

    2006-01-01

    This is Version 3.0 of the planetary mission entry vehicle document. Three new missions, Re-entry F, Hayabusa, and ARD have been added to t he previously published edition (Version 2.1). In addition, the Huyge ns mission has been significantly updated and some Apollo data correc ted. Due to the changing nature of planetary vehicles during the desi gn, manufacture and mission phases, and to the variables involved in measurement and computation, please be aware that the data provided h erein cannot be guaranteed. Contact Carol Davies at cdavies@mail.arc. nasa.gov to correct or update the current data, or to suggest other missions.

  8. ARROW (Version 2) Commercial Software Validation and Configuration Control

    Energy Technology Data Exchange (ETDEWEB)

    HEARD, F.J.

    2000-02-10

    ARROW (Version 2), a compressible flow piping network modeling and analysis computer program from Applied Flow Technology, was installed for use at the U.S. Department of Energy Hanford Site near Richland, Washington.

  9. ARROW (Version 2) Commercial Software Validation and Configuration Control

    International Nuclear Information System (INIS)

    HEARD, F.J.

    2000-01-01

    ARROW (Version 2), a compressible flow piping network modeling and analysis computer program from Applied Flow Technology, was installed for use at the U.S. Department of Energy Hanford Site near Richland, Washington

  10. Chinese version of the Global Youth Tobacco Survey: cross-cultural instrument adaptation

    Directory of Open Access Journals (Sweden)

    Chiou Hung-Yi

    2008-04-01

    Full Text Available Abstract Background Tobacco smoking poses public health concerns because of its high risk for many chronic diseases. Most smokers begin using tobacco in their teens and recent reports indicate that smoking prevalence is climbing among youth. The Global Youth Tobacco Survey (GYTS is a worldwide, school-based, tobacco-specific survey, but cross-cultural differences limit its effectiveness in international studies. Specifically, the GYTS assesses not only the prevalence of smoking, but also tobacco-related attitudes, school curricula, and advertisements, which are culturally influenced. Therefore, we conducted this study to develop a Chinese version of the GYTS for both national surveillance and international comparison. Methods The original English GYTS was translated and back translated using a cross-cultural adaptation process. The comprehensiveness and feasibility of using the Chinese-version GYTS were reviewed by a panel of 6 tobacco-control experts. The understandability and cultural relevance of the Chinese-version GYTS were discussed in a focus group of 5 schoolteachers and 8 students. The expert and focus group feedback was incorporated into a final Chinese version of the GYTS, which was administered to 382 students throughout Taiwan by multi-stage sampling from 10 randomly selected schools. Results The internal consistency (Cronbach's alpha for the GYTS subscales (smoking susceptibility, attitude toward smoking, and media messages about smoking ranged from 0.70 to 0.94. The internal logical agreement of responses ranged from 85.3 to 99.2%. Conclusion The Chinese version of the GYTS has good reliability and validity and can serve as the foundation for international comparison and tobacco control in Chinese-speaking communities.

  11. Validation of the Arabic Version of the Internet Gaming Disorder-20 Test.

    Science.gov (United States)

    Hawi, Nazir S; Samaha, Maya

    2017-04-01

    In recent years, researchers have been trying to shed light on gaming addiction and its association with different psychiatric disorders and psychological determinants. The latest edition version of the American Psychiatric Association's Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) included in its Section 3 Internet Gaming Disorder (IGD) as a condition for further empirical study and proposed nine criteria for the diagnosis of IGD. The 20-item Internet Gaming Disorder (IGD-20) Test was developed as a valid and reliable tool to assess gaming addiction based on the nine criteria set by the DSM-5. The aim of this study is to validate an Arabic version of the IGD-20 Test. The Arabic version of IGD-20 will not only help in identifying Arabic-speaking pathological gamers but also stimulate cross-cultural studies that could contribute to an area in need of more research for insight and treatment. After a process of translation and back-translation and with the participation of a sizable sample of Arabic-speaking adolescents, the present study conducted a psychometric validation of the IGD-20 Test. Our confirmatory factor analysis showed the validity of the Arabic version of the IGD-20 Test. The one-factor model of the Arabic IGD-20 Test had very good psychometric properties, and it fitted the sample data extremely well. In addition, correlation analysis between the IGD-20 Test and the daily duration on weekdays and weekends gameplay revealed significant positive relationships that warranted a criterion-related validation. Thus, the Arabic version of the IGD-20 Test is a valid and reliable measure of IGD among Arabic-speaking populations.

  12. Building Identification Wizard: Version 1.5.1

    Science.gov (United States)

    2018-04-01

    develops innovative solutions in civil and military engineering , geospatial sciences, water resources, and environmental sciences for the Army, the...unlimited. The U.S. Army Engineer Research and Development Center (ERDC) solves the nation’s toughest engineering and environmental challenges. ERDC...April 2018 Building Identification Wizard Version 1.5.1 M. Jason Roth U.S. Army Engineer Research and Development Center (ERDC) Geotechnical and

  13. A 1D version of EllipSys

    DEFF Research Database (Denmark)

    van der Laan, Paul; Sørensen, Niels N.

    2017-01-01

    A one-dimensional version of EllipSys, labeled as EllipSys1D is presented. Three atmospheric boundary layer test cases are used to show that results of EllipSys1D are exactly the same or very similar as results of EllipSys3D, while EllipSys1D uses 3 to 4 orders of magnitude less CPU hours compared...

  14. Psychometric validation of a German version of the compulsive Internet use scale.

    Science.gov (United States)

    Wartberg, Lutz; Petersen, Kay-Uwe; Kammerl, Rudolf; Rosenkranz, Moritz; Thomasius, Rainer

    2014-02-01

    Excessive Internet use and Internet addiction are currently increasing in many industrial nations. Verified and validated measuring instruments could contribute to a better understanding of this still quite recent development. The aim of this survey was to investigate the psychometric properties of a German version of the Compulsive Internet Use Scale (CIUS). We surveyed a representative German quota sample of 1,723 adolescents aged between 14 and 17 years, as well as one parent each, with standardized questionnaires. In addition, adolescents and parents were asked whether the media use by the youth was considered problematic or excessive, and whether it led to arguments at home. We conducted confirmatory factor analyses (CFA) with maximum likelihood estimation to examine the factorial validity of the German CIUS, as well as reliability and correlation analyses. The results of the CFA indicate good psychometric properties for the German version of the CIUS. They appear in line with the findings for the original version of the questionnaire. Furthermore, the CIUS showed high internal consistency, and we found significant correlations between the "CIUS-summary score" and different ratings of problems with the media usage by the youth and the parents. The German version of the CIUS seems to be a valid and suitable diagnostic tool for measuring problematic to pathological Internet use.

  15. MACCS version 1.5.11.1: A maintenance release of the code

    International Nuclear Information System (INIS)

    Chanin, D.; Foster, J.; Rollstin, J.; Miller, L.

    1993-10-01

    A new version of the MACCS code (version 1.5.11.1) has been developed by Sandia National Laboratories under sponsorship of the US Nuclear Regulatory Commission. MACCS was developed to support evaluations of the off-site consequences from hypothetical severe accidents at commercial power plants. MACCS is the only current public domain code in the US that embodies all of the following modeling capabilities: (1) weather sampling using a year of recorded weather data; (2) mitigative actions such as evacuation, sheltering, relocation, decontamination, and interdiction; (3) economic costs of mitigative actions; (4) cloudshine, groundshine, and inhalation pathways as well as food and water ingestion; (5) calculation of both individual and societal doses to various organs; and (6) calculation of both acute (nonstochastic) and latent (stochastic) health effects and risks of health effects. All of the consequence measures may be fun generated in the form of a complementary cumulative distribution function (CCDF). The current version implements a revised cancer model consistent with recent reports such as BEIR V and ICRP 60. In addition, a number of error corrections and portability enhancements have been implemented. This report describes only the changes made in creating the new version. Users of the code will need to obtain the code's original documentation, NUREG/CR-4691

  16. Children's Recall of the News: TV News Stories Compared with Three Print Versions.

    Science.gov (United States)

    van der Molen, Juliette H. Walma; van der Voort, Tom H. A.

    1998-01-01

    A sample of 144 fourth and sixth graders was presented with five children's news stories, in television form or in one of three print versions. Results indicated that children who watched news on television remembered the stories better than children who read one of the three print versions, regardless of their level of reading proficiency.…

  17. The Translation Equivalence of Two Japanese Versions of theRosenberg Self-Esteem Scale

    OpenAIRE

    Brown, R. A.

    2010-01-01

    The present research investigated the comparability of two commonly used Japanese translationsof the Rosenberg Self-esteem Scale (RSES). Study 1 revealed that participants evaluated themselvesmore negatively on one version that the other. Study 2 however showed that participants did notevaluate a target person who was depicted endorsing the RSES items significantly differentlyregardless which version was used.

  18. Psychometric Evaluation of the Hebrew Language Version of the Satisfaction with Life Scale

    Science.gov (United States)

    Anaby, Dana; Jarus, Tal; Zumbo, Bruno D.

    2010-01-01

    The satisfaction with life scale (SWLS) is a widely accepted and widely used tool for measuring well-being. Although its potential as a cross-cultural index is recognized, an introduction and systematic validation of the Hebrew version is needed. Thus, the purpose of this study is: (1) to describe the process of developing the Hebrew version of…

  19. Psychometric Evaluation of the Serbian Version of the Multidimensional Students' Life Satisfaction Scale

    Science.gov (United States)

    Jovanovic, Veljko; Zuljevic, Dragan

    2013-01-01

    The main purpose of this study was to evaluate psychometric properties of the Serbian version of the Multidimensional Students' Life Satisfaction Scale (MSLSS). The research was carried out on a sample of 408 high school students (250 females, 158 males), with the mean age 16.6. The Serbian version of the MSLSS has demonstrated good psychometric…

  20. Evaluation of Psychometric Properties of the Malay Version ...

    African Journals Online (AJOL)

    The 10-item version of Perceived Stress Scale (PSS-10) is a widely used ... 2International Medical School, Management and Science University, University Drive, Off Persiaran Olahraga, Section 13, ... Ethics Committee of the National Institutes of Health, Ministry ... value of Cronbach's alpha did not improve despite items.

  1. Factorial and construct validity of Portuguese version (Brazil Bergen Facebook Addiction Scale

    Directory of Open Access Journals (Sweden)

    Hugo Rafael de Souza e Silva

    Full Text Available ABSTRACT Objective To evaluate factorial and construct validity of the Brazilian Portuguese version of the Bergen Facebook Addiction Scale (BFAS-BR. Methods A sociodemographic questionnaire, the Brazilian Portuguese versions of Online Cognition Scale (OCS-BR and of BFAS-BR were applied to a sample of Health Undergraduate (n = 356. Construct validity evidences were verified through the Confirmatory Factor Analysis. Discriminant validity was examined by correlational analysis between the version of the BFAS-BR and OCS-BR. Results Proposed factorial model of BFAS did not present a good quality adjustment. So, a model restructuring was necessary from behavioral addiction theoretical views and new model presented satisfactory adjustment quality and construct validity evidence. Correlation between both tested scales was strong (ρ = 0.707 and, therefore, they measure the same construct. Conclusion The BFAS-BR show adequate factorial and construct validity.

  2. Climate Forecast System Version 2 (CFSv2) Operational Forecasts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Climate Forecast System Version 2 (CFSv2) produced by the NOAA National Centers for Environmental Prediction (NCEP) is a fully coupled model representing the...

  3. Climate Forecast System Version 2 (CFSv2) Operational Analysis

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Climate Forecast System Version 2 (CFSv2) produced by the NOAA National Centers for Environmental Prediction (NCEP) is a fully coupled model representing the...

  4. Global Historical Climatology Network - Monthly Temperature, Version 4 (BETA)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Only available as BETA release. The GHCN-Monthly Temperature Version 4 dataset consists of monthly mean temperature - both raw and bias corrected data. A full...

  5. A new version of the event generator Sibyll

    CERN Document Server

    Riehn, Felix; Fedynitch, Anatoli; Gaisser, Thomas K.; Stanev, Todor

    2016-01-01

    The event generator Sibyll can be used for the simulation of hadronic multiparticle production up to the highest cosmic ray energies. It is optimized for providing an economic description of those aspects of the expected hadronic final states that are needed for the calculation of air showers and atmospheric lepton fluxes. New measurements from fixed target and collider experiments, in particular those at LHC, allow us to test the predictive power of the model version 2.1, which was released more than 10 years ago, and also to identify shortcomings. Based on a detailed comparison of the model predictions with the new data we revisit model assumptions and approximations to obtain an improved version of the interaction model. In addition a phenomenological model for the production of charm particles is implemented as needed for the calculation of prompt lepton fluxes in the energy range of the astrophysical neutrinos recently discovered by IceCube. After giving an overview of the new ideas implemented in Sibyll...

  6. A new version of a free electron laser Two-Beam Accelerator

    International Nuclear Information System (INIS)

    Sessler, A.M.; Sternbach, E.; Wurtele, J.S.

    1988-09-01

    A new version of a Two-Beam Accelerator is proposed in which in each period of the drive structure a very small input microwave signal is amplified to a large power level and then completely removed and transferred to the accelerating structure. In this manner a number of difficulties with the original version are eliminated or greatly relieved; namely, rf phase and amplitude sensitivity, growth of sidebands, and rf manipulation (removal of the microwaves from the drive structure, and transmission of microwave power through the accelerating cavities). 11 refs., 6 figs., 2 tabs

  7. Verification of reliability and validity of a Japanese version of the Rathus Assertiveness Schedule.

    Science.gov (United States)

    Suzuki, Eiko; Kanoya, Yuka; Katsuki, Takeshi; Sato, Chifumi

    2007-07-01

    To verify the reliability and validity of a Japanese version of the Rathus Assertiveness Schedule in novice nurses to contribute to nursing management. An adequate scale is needed to measure the assertiveness and the effect of assertion training for Japanese nurses and to compare them with those in other countries. Rathus Assertiveness Schedule was adapted to Japanese with back-translation and its validity was examined in 989 novice nurses. The Japanese version showed a high coefficient of reliability in a split-half reliability test (r=0.76; PAssertiveness Schedule. The Japanese version of Rathus Assertiveness Schedule was verified.

  8. PROBLEM OF SUPPORTING THE VERSIONS OF DISTANCE EDUCATION SYSTEM MOODLE IN THE MEDICAL UNIVERSITY

    Directory of Open Access Journals (Sweden)

    Andrii V. Semenets

    2014-01-01

    Full Text Available Moodle is one of the open-source software learning management system using to support an educational process. The problem of updating the outdated Moodle versions is studied in the article. It is shown a successful implementation of a modified version on the basis of I. Ya. Horbachevsky Ternopil State Medical University. The step-by-step manual of the updating and a new server migration process are described. Examples of the application of the virtualization techniques and version control system to the SDE Moodle system administration tasks solving are presented. The SDE Moodle server optimization and customization recommendations are also given.

  9. RASCAL Version 2.1 workbook. Volume 2, Revision 2

    International Nuclear Information System (INIS)

    Athey, G.F.; Sjoreen, A.L.; McKenna, T.J.

    1994-12-01

    The Radiological Assessment System for Consequence Analysis, Version 2.1 (RASCAL 2.1) was developed for use by the NRC personnel who respond to radiological emergencies. This workbook complements the RASCAL 2.1 User's guide (NUREG/CR-5247, Vol. 1, Rev. 2). The workbook contains exercises designed to familiarize the user with the computer-based tools of RASCAL through hands-on problem solving. The workbook contains four major sections. The first is a RASCAL familiarization exercise to acquaint the user with the operation of the forms, menus, online help, and documentation. The latter three sections contain exercises in using the three tools of RASCAL Version 2.1: DECAY, FM-DOSE, and ST-DOSE. A discussion section describing how the tools could be used to solve the problems follows each set of exercises

  10. Analgesia/anesthesia for external cephalic version.

    Science.gov (United States)

    Weiniger, Carolyn F

    2013-06-01

    Professional society guidelines recommend that women with breech presentation be delivered surgically due to a higher incidence of fetal risks compared with vaginal delivery. An alternative is attempted external cephalic version, which if successful, enables attempted vaginal delivery. Attitudes towards external cephalic version (ECV) will be considered in this review, along with pain relief methods and their impact on ECV success rates. Articles suggest that ECV is infrequently offered, due to both physician and patient factors. Success of ECV is higher in multiparous women, complete breech, posterior placenta, or smaller fetus. Preterm ECV performance does not increase vaginal delivery rates. Neuraxial techniques (spinal or epidural) significantly increase ECV success rates, as do moxibustion and hypnosis. Four reviews summarized studies considering ECV and neuraxial techniques. These reviews suggest that neuraxial techniques using high (surgical) doses of local anesthetic are efficacious compared with control groups not using anesthesia, whereas techniques using low-doses are not. Low-dose versus high-dose neuraxial analgesia/anesthesia has not been directly compared in a single study. Based on currently available data, the rate of cephalic presentation is not increased using neuraxial techniques, but vaginal delivery rates are higher. ECV appears to be a low-risk procedure. The logistics of routine ECV and provision of optimal neuraxial techniques for successful ECV require additional research. Safety aspects of neuraxial anesthesia for ECV require further investigation.

  11. NOAA Climate Data Record (CDR) of Reflectance from AVHRR Pathfinder Atmospheres - Extended (PATMOS-x), Version 5.2 (Superseded)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Please note: this dataset has been superseded by a newer version (see below). This version is archived offline by NOAA NCEI. Users should not obtain this version...

  12. Validation of the Hebrew version of the Movement Disorder Society-Unified Parkinson's Disease Rating Scale.

    Science.gov (United States)

    Zitser, Jennifer; Peretz, Chava; Ber David, Aya; Shabtai, Herzl; Ezra, Adi; Kestenbaum, Meir; Brozgol, Marina; Rosenberg, Alina; Herman, Talia; Balash, Yakov; Gadoth, Avi; Thaler, Avner; Stebbins, Glenn T; Goetz, Christopher G; Tilley, Barbara C; Luo, Sheng T; Liu, Yuanyuan; Giladi, Nir; Gurevich, Tanya

    2017-12-01

    The Movement Disorders Society (MDS) published the English new Unified Parkinson's Disease Rating Scale (MDS-UPDRS) as the official benchmark scale for Parkinson's disease (PD) in 2008. We aimed to validate the Hebrew version of the MDS-UPDRS, explore its dimensionality and compare it to the original English one. The MDS-UPDRS questionnaire was translated to Hebrew and was tested on 389 patients with PD, treated at the Movement Disorders Unit at Tel-Aviv Medical Center. The MDS-UPDRS is made up of four sections. The higher the score, the worst the clinical situation of the patient is. Confirmatory and explanatory factor analysis were applied to determine if the factor structure of the English version could be confirmed in the Hebrew version. The Hebrew version of the MDS-UPDRS showed satisfactory clinimetric properties. The internal consistency of the Hebrew-version was satisfactory, with Cronbach's alpha values 0.79, 0.90, 0.93, 0.80, for parts 1 to 4 respectively. In the confirmatory factor analysis, all four parts had high (greater than 0.90) comparative fit index (CFI) in comparison to the original English MDS-UPDRS with high factor structure (0.96, 0.99, 0.94, 1.00, respectively), thus confirming the pre-specified English factor structure. Explanatory factor analysis yielded that the Hebrew responses differed from the English one within an acceptable range: in isolated item differences in factor structure and in the findings of few items having cross loading on multiple factors. The Hebrew version of the MDS-UPDRS meets the requirements to be designated as the Official Hebrew Version of the MDS-UPDRS. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Procedure guideline for radioiodine test (version 3); Verfahrensanweisung zum Radioiodtest (Version 3)

    Energy Technology Data Exchange (ETDEWEB)

    Dietlein, M.; Schicha, H. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Dressler, J. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Nuklearmedizinische Klinik der Henriettenstiftung, Hannover (Germany); Eschner, W. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Deutsche Gesellschaft fuer Medizinische Physik (DGMP) (Germany); Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Lassmann, M. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Deutsche Gesellschaft fuer Medizinische Physik (DGMP) (Germany); Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Leisner, B. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Allgemeines Krankenhaus St. Georg, Hamburg (Germany). Abt. fuer Nuklearmedizin; Reiners, C. [Deutsche Gesellschaft fuer Nuklearmedizin (DGN) (Germany); Wuerzburg Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    2007-07-01

    The version 3 of the procedure guideline for radioiodine test is an update of the guideline previously published in 2003. The procedure guideline discusses the pros and cons of a single measurement or of repeated measurements of the iodine-131 uptake and their optimal timing. Different formulas are described when one, two or three values of the radioiodine kinetic are available. The probe with a sodium-iodine crystal, alternatively or additionally the gamma camera using the ROI-technique are instrumentations for the measurement of iodine-131 uptake. A possible source of error is an inappropriate measurement (sonography) of the target volume. The patients' preparation includes the withdrawal of antithyroid drugs 2-3 days before radioiodine administration. The patient has to avoid iodine-containing medication and the possibility of additives of iodine in vitamin- and electrolyte-supplementation has to be considered. (orig.)

  14. Original Research Psychometric evaluation of the Shona version of ...

    African Journals Online (AJOL)

    ... version of the. Multidimensional Scale of Perceived Social Support ... informal caregivers in the management of long term health conditions ... cultural translations and adaptations of PROs.15 Given how ...... Asia Pac J Public Health. 2015 ...

  15. Global Precipitation Climatology Project (GPCP) - Daily, Version 1.2

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Global Precipitation Climatology Project (GPCP) comprises a total of 27 products. The Version 1.2 Daily product covers the period October 1998 to the present,...

  16. Global Precipitation Climatology Project (GPCP) - Pentad, Version 2.2

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Global Precipitation Climatology Project (GPCP) comprises a total of 27 products. The Version 2.2 Pentad product covers the period January 1979 to the present,...

  17. Main modelling features of the ASTEC V2.1 major version

    International Nuclear Information System (INIS)

    Chatelard, P.; Belon, S.; Bosland, L.; Carénini, L.; Coindreau, O.; Cousin, F.; Marchetto, C.; Nowack, H.; Piar, L.; Chailan, L.

    2016-01-01

    Highlights: • Recent modelling improvements of the ASTEC European severe accident code are outlined. • Key new physical models now available in the ASTEC V2.1 major version are described. • ASTEC progress towards a multi-design reactor code is illustrated for BWR and PHWR. • ASTEC strong link with the on-going EC CESAM FP7 project is emphasized. • Main remaining modelling issues (on which IRSN efforts are now directing) are given. - Abstract: A new major version of the European severe accident integral code ASTEC, developed by IRSN with some GRS support, was delivered in November 2015 to the ASTEC worldwide community. Main modelling features of this V2.1 version are summarised in this paper. In particular, the in-vessel coupling technique between the reactor coolant system thermal-hydraulics module and the core degradation module has been strongly re-engineered to remove some well-known weaknesses of the former V2.0 series. The V2.1 version also includes new core degradation models specifically addressing BWR and PHWR reactor types, as well as several other physical modelling improvements, notably on reflooding of severely damaged cores, Zircaloy oxidation under air atmosphere, corium coolability during corium concrete interaction and source term evaluation. Moreover, this V2.1 version constitutes the back-bone of the CESAM FP7 project, which final objective is to further improve ASTEC for use in Severe Accident Management analysis of the Gen.II–III nuclear power plants presently under operation or foreseen in near future in Europe. As part of this European project, IRSN efforts to continuously improve both code numerical robustness and computing performances at plant scale as well as users’ tools are being intensified. Besides, ASTEC will continue capitalising the whole knowledge on severe accidents phenomenology by progressively keeping physical models at the state of the art through a regular feed-back from the interpretation of the current and

  18. JaxoDraw: A graphical user interface for drawing Feynman diagrams. Version 2.0 release notes

    Science.gov (United States)

    Binosi, D.; Collins, J.; Kaufhold, C.; Theussl, L.

    2009-09-01

    A new version of the Feynman graph plotting tool JaxoDraw is presented. Version 2.0 is a fundamental re-write of most of the JaxoDraw core and some functionalities, in particular importing graphs, are not backward-compatible with the 1.x branch. The most prominent new features include: drawing of Bézier curves for all particle modes, on-the-fly update of edited objects, multiple undo/redo functionality, the addition of a plugin infrastructure, and a general improved memory performance. A new LaTeX style file is presented that has been written specifically on top of the original axodraw.sty to meet the needs of this new version. New version program summaryProgram title: JaxoDraw Catalogue identifier: ADUA_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADUA_v2_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GPL No. of lines in distributed program, including test data, etc.: 103 544 No. of bytes in distributed program, including test data, etc.: 3 745 814 Distribution format: tar.gz Programming language: Java Computer: Any Java-enabled platform Operating system: Any Java-enabled platform, tested on Linux, Windows XP, Mac OS X Classification: 14 Catalogue identifier of previous version: ADUA_v1_0 Journal reference of previous version: Comput. Phys. Comm. 161 (2004) 76 Does the new version supersede the previous version?: Yes Nature of problem: Existing methods for drawing Feynman diagrams usually require some hard-coding in one or the other programming or scripting language. It is not very convenient and often time consuming, to generate relatively simple diagrams. Solution method: A program is provided that allows for the interactive drawing of Feynman diagrams with a graphical user interface. The program is easy to learn and use, produces high quality output in several formats and runs on any operating system where a Java Runtime Environment is available. Reasons for new version: A

  19. Analyzing and comparing the two grade- ten mathematics textbooks versions (Arabic and English used in Abu Dhabi schools.

    Directory of Open Access Journals (Sweden)

    Yousef Abosalem

    2016-03-01

    Full Text Available This study was conducted to compare two grade- ten mathematics textbooks according to Bloom's Taxonomies. In the Arabic version, 37 out of 70 periods (55.29% were given to plane geometry and trigonometry, whereas 29 out of 70 periods (41.41% were allocated for geometry and trigonometry. Also, 12 periods (17.14% were allocated for algebra in the Arabic version, whereas 19 periods (27.14% in the English version. As concluded in the above percentages, more concentration was given to geometry in the Arabic version compared to Algebra in the English version. The results indicated that in the geometry chapter in the Arabic version, the educational objectives percentages ranged from 40.0 %( comprehension to 8.75 (synthesis and evaluation, and 62.86 % of the educational objectives were in the lower levels of Bloom's Taxonomies. Whereas in the English version the Geometry chapter ranged from 45.65 % (application to 10.87% (synthesis, and for the same chapters, 63.04 % were in the lower levels of Bloom's taxonomies. For the Algebra chapter, the objectives ranged from 56.25% (application to 6.25 %( synthesis and evaluation and from 47.62 % (application to 4.76 % (comprehension and synthesis in the Arabic and English versions respectively. With respect to educational objectives, 79.11 % of the educational objectives were at the application level in Arabic version compared to 93.27 % for the application in the English one.

  20. Reliability and Construct Validity of Two Versions of Chalder Fatigue Scale among the General Population in Mainland China

    Directory of Open Access Journals (Sweden)

    Meng-Juan Jing

    2016-01-01

    Full Text Available The 14-item Chalder Fatigue Scale (CFS is widely used, while the 11-item version is seldom to be found in current research in mainland China. The objectives of the present study is to compare the reliability and construct validity between these two versions and to confirm which may be better for the mainland Chinese setting. Based on a cross-sectional health survey with a constructive questionnaire, 1887 individuals aged 18 years or above were selected. Socio-demographic, health-related, gynecological data were collected, and 11-item and 14-item Chalder Fatigue Scale (CFS were used to assess fatigue. Confirmatory factor analysis and exploratory structural equation modeling (ESEM were performed to test the fit of models of the two versions. Confirmatory factor analysis of the two versions of CFS did not support the two-factor theorized models. In addition, a three-factor ESEM model of the 11-item version, but not the 14-item version, showed better factor structure and fitness than the other models examined. Both the versions had good internal consistency reliability and a satisfactory internal consistency (Ω = 0.78–0.96, omega coefficient indicates the internal consistency reliability was obtained from the optimal model. This study provided evidence for satisfactory reliability and structural validity for the three-factor model of the 11-item version, which was proven to be superior to the 14-item version for this data.

  1. A Quantum Version of Wigner's Transition State Theory

    NARCIS (Netherlands)

    Schubert, R.; Waalkens, H.; Wiggins, S.

    A quantum version of a recent realization of Wigner's transition state theory in phase space is presented. The theory developed builds on a quantum normal form which locally decouples the quantum dynamics near the transition state to any desired order in (h) over bar. This leads to an explicit

  2. Engestrom's Version of Activity Theory: A Conservative Praxis?

    Science.gov (United States)

    Avis, James

    2007-01-01

    This article examines Engestrom's version of activity theory, one rooted in Marxism. It is argued that whilst this approach holds progressive possibilities, its radicalism is undermined by a restricted conceptualisation of transformation and the marginalisation of a politicised notion of social antagonism. As a consequence, this approach to…

  3. A conceptual model specification language (CMSL Version 2)

    NARCIS (Netherlands)

    Wieringa, Roelf J.

    1992-01-01

    Version 2 of a language (CMSL) to specify conceptual models is defined. CMSL consists of two parts, the value specification language VSL and the object spercification language OSL. There is a formal semantics and an inference system for CMSL but research on this still continues. A method for

  4. Chinese version of the Constant-Murley questionnaire for shoulder pain and disability: a reliability and validation study.

    Science.gov (United States)

    Yao, Min; Yang, Long; Cao, Zuo-Yuan; Cheng, Shao-Dan; Tian, Shuang-Lin; Sun, Yue-Li; Wang, Jing; Xu, Bao-Ping; Hu, Xiao-Chun; Wang, Yong-Jun; Zhang, Ying; Cui, Xue-Jun

    2017-09-18

    Shoulder pain is a common musculoskeletal disorder in Chinese population, which affects more than 1,3 billion individuals. To the best of our knowledge, there has been no available Chinese-language version of measurements of shoulder pain and disability so far. Moreover, the Constant-Murley score (CMS) questionnaire is a universally recognized patient-reported questionnaire for clinical practice and research. The present study was designed to evaluate a Chinese translational version of CMS and subsequently assess its reliability and validity. The Chinese translational version of CMS was formulated by means of forward-backward translation. Meanwhile, a final review was carried out by an expert committee, followed by conducting a test of the pre-final version. Therefore, the reliability and validity of the Chinese translational version of CMS could be assessed using the internal consistency, construct validity, factor analysis, reliability and floor and ceiling effects. Specifically, the reliability was assessed by testing the internal consistency (Cronbach's α) and test-retest reliability (intraclass coefficient correlation [ICC]), while the construct validity was evaluated via comparison between the Chinese translational version of CMS with visual analog scale (VAS) score and the 36-Item Short Form Health Survey (SF-36, Spearman correlation). The questionnaire was verified to be acceptable after distribution among 120 subjects with unilateral shoulder pain. Factor analysis had revealed a two-factor and 10-item solution. Moreover, the assessment results indicated that the Chinese translational version of CMS questionnaire harbored good internal consistency (Cronbach's α = 0.739) and test-retest reliability (ICC = 0.827). In addition, the Chinese translational version of CMS was moderately correlated with VAS score (r = 0.497) and SF-36 (r = 0.135). No obvious floor and ceiling effects were observed in the Chinese translational version of CMS questionnaire

  5. East Asian Seas Regional Climatology Version 2.0 from 1804 to 2014 (NODC Accession 0123300)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The East Asian Seas Regional Climatology Version 2.0 is an update to the preliminary version released in May 2012. This update includes new temperature and salinity...

  6. TRASYS - THERMAL RADIATION ANALYZER SYSTEM (DEC VAX VERSION WITH NASADIG)

    Science.gov (United States)

    Anderson, G. E.

    1994-01-01

    . The flexible structure of TRASYS allows considerable freedom in the definition and choice of solution method for a thermal radiation problem. The program's flexible structure has also allowed TRASYS to retain the same basic input structure as the authors update it in order to keep up with changing requirements. Among its other important features are the following: 1) up to 3200 node problem size capability with shadowing by intervening opaque or semi-transparent surfaces; 2) choice of diffuse, specular, or diffuse/specular radiant interchange solutions; 3) a restart capability that minimizes recomputing; 4) macroinstructions that automatically provide the executive logic for orbit generation that optimizes the use of previously completed computations; 5) a time variable geometry package that provides automatic pointing of the various parts of an articulated spacecraft and an automatic look-back feature that eliminates redundant form factor calculations; 6) capability to specify submodel names to identify sets of surfaces or components as an entity; and 7) subroutines to perform functions which save and recall the internodal and/or space form factors in subsequent steps for nodes with fixed geometry during a variable geometry run. There are two machine versions of TRASYS v27: a DEC VAX version and a Cray UNICOS version. Both versions require installation of the NASADIG library (MSC-21801 for DEC VAX or COS-10049 for CRAY), which is available from COSMIC either separately or bundled with TRASYS. The NASADIG (NASA Device Independent Graphics Library) plot package provides a pictorial representation of input geometry, orbital/orientation parameters, and heating rate output as a function of time. NASADIG supports Tektronix terminals. The CRAY version of TRASYS v27 is written in FORTRAN 77 for batch or interactive execution and has been implemented on CRAY X-MP and CRAY Y-MP series computers running UNICOS. The standard distribution medium for MSC-21959 (CRAY version

  7. TRASYS - THERMAL RADIATION ANALYZER SYSTEM (DEC VAX VERSION WITHOUT NASADIG)

    Science.gov (United States)

    Vogt, R. A.

    1994-01-01

    . The flexible structure of TRASYS allows considerable freedom in the definition and choice of solution method for a thermal radiation problem. The program's flexible structure has also allowed TRASYS to retain the same basic input structure as the authors update it in order to keep up with changing requirements. Among its other important features are the following: 1) up to 3200 node problem size capability with shadowing by intervening opaque or semi-transparent surfaces; 2) choice of diffuse, specular, or diffuse/specular radiant interchange solutions; 3) a restart capability that minimizes recomputing; 4) macroinstructions that automatically provide the executive logic for orbit generation that optimizes the use of previously completed computations; 5) a time variable geometry package that provides automatic pointing of the various parts of an articulated spacecraft and an automatic look-back feature that eliminates redundant form factor calculations; 6) capability to specify submodel names to identify sets of surfaces or components as an entity; and 7) subroutines to perform functions which save and recall the internodal and/or space form factors in subsequent steps for nodes with fixed geometry during a variable geometry run. There are two machine versions of TRASYS v27: a DEC VAX version and a Cray UNICOS version. Both versions require installation of the NASADIG library (MSC-21801 for DEC VAX or COS-10049 for CRAY), which is available from COSMIC either separately or bundled with TRASYS. The NASADIG (NASA Device Independent Graphics Library) plot package provides a pictorial representation of input geometry, orbital/orientation parameters, and heating rate output as a function of time. NASADIG supports Tektronix terminals. The CRAY version of TRASYS v27 is written in FORTRAN 77 for batch or interactive execution and has been implemented on CRAY X-MP and CRAY Y-MP series computers running UNICOS. The standard distribution medium for MSC-21959 (CRAY version

  8. SERA: Simulation Environment for Radiotherapy Applications - Users Manual Version 1CO

    International Nuclear Information System (INIS)

    Venhuizen, James Robert; Wessol, Daniel Edward; Wemple, Charles Alan; Wheeler, Floyd J; Harkin, G. J.; Frandsen, M. W.; Albright, C. L.; Cohen, M.T.; Rossmeier, M.; Cogliati, J.J.

    2002-01-01

    This document is the user manual for the Simulation Environment for Radiotherapy Applications (SERA) software program developed for boron-neutron capture therapy (BNCT) patient treatment planning by researchers at the Idaho National Engineering and Environmental Laboratory (INEEL) and students and faculty at Montana State University (MSU) Computer Science Department. This manual corresponds to the final release of the program, Version 1C0, developed to run under the RedHat Linux Operating System (version 7.2 or newer) or the Solaris Operating System (version 2.6 or newer). SERA is a suite of command line or interactively launched software modules, including graphical, geometric reconstruction, and execution interface modules for developing BNCT treatment plans. The program allows the user to develop geometric models of the patient as derived from Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) images, perform dose computation for these geometric models, and display the computed doses on overlays of the original images as three dimensional representations. This manual provides a guide to the practical use of SERA, but is not an exhaustive treatment of each feature of the code

  9. Content and functions of the pilot version 1 of RODOS/RESY

    International Nuclear Information System (INIS)

    Benz, G.; Ehrhardt, J.; Faude, D.; Fischer, F.; Paesler-Sauer, J.; Rafat, M.; Schichtel, T.; Schuele, O.; Steinhauer, C.

    1994-01-01

    RODOS/RESY is an integrated real-time on-line decision support system for external emergency management after nuclear accidents. It is part of the comprehensive RODOS-system (real-time on-line decision support), which is designed for use in Europe after accidental releases of radioactive material to the atmosphere and hydrosphere. RODOS/RESY is limited in its applicability to the near range of nuclear facilities and the early phase of an accident with airborne radioactive releases. Therefore, it serves directly as a decision-aiding tool for countermeasure actions in the responsibility of local emergency management authorities. At present, RODOS is and RandD project which aims at the further development for operational use of the first prototype version completed in autumn 1992. A first step towards this goal will be the pilot version 1 of RODOS/RESY, which bill be ready by the end of 1994 for coupling to monitoring networks of nuclear reactor remote control surveillance systems and pre-operational use. The report describes the structure, content and functions of this pilot version. (orig.) [de

  10. SERA: Simulation Environment for Radiotherapy Applications - Users Manual Version 1CO

    Energy Technology Data Exchange (ETDEWEB)

    Venhuizen, James Robert; Wessol, Daniel Edward; Wemple, Charles Alan; Wheeler, Floyd J; Harkin, G. J.; Frandsen, M. W.; Albright, C. L.; Cohen, M.T.; Rossmeier, M.; Cogliati, J.J.

    2002-06-01

    This document is the user manual for the Simulation Environment for Radiotherapy Applications (SERA) software program developed for boron-neutron capture therapy (BNCT) patient treatment planning by researchers at the Idaho National Engineering and Environmental Laboratory (INEEL) and students and faculty at Montana State University (MSU) Computer Science Department. This manual corresponds to the final release of the program, Version 1C0, developed to run under the RedHat Linux Operating System (version 7.2 or newer) or the Solaris™ Operating System (version 2.6 or newer). SERA is a suite of command line or interactively launched software modules, including graphical, geometric reconstruction, and execution interface modules for developing BNCT treatment plans. The program allows the user to develop geometric models of the patient as derived from Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) images, perform dose computation for these geometric models, and display the computed doses on overlays of the original images as three dimensional representations. This manual provides a guide to the practical use of SERA, but is not an exhaustive treatment of each feature of the code.

  11. IDC System Specification Document Version 1.1.

    Energy Technology Data Exchange (ETDEWEB)

    Harris, James M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lober, Randall R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-01

    This document contains the system specifications derived to satisfy the system requirements found in the IDC System Requirements Document for the IDC Reengineering Phase 2 project. Revisions Version Date Author/Team Revision Description Authorized by V1.0 12/2014 IDC Reengineering Project Team Initial delivery M. Harris V1.1 2/2015 IDC Reengineering Project Team Iteration I2 Review Comments M. Harris

  12. The Danish version of the Medication Adherence Report Scale: preliminary validation in cancer pain patients

    DEFF Research Database (Denmark)

    Jacobsen, Ramune; Møldrup, Claus; Christrup, Lona Louring

    2009-01-01

    into Danish following the repeated back-translation procedure. Cancer patients for the study were recruited from specialized pain management facilities. Thirty-three patients responded to the DMARS-4, the Danish Barriers Questionnaire II, The Danish version of Patient Perceived Involvement in Care Scale......OBJECTIVE: To examine the psychometric properties of the Danish version of the Medication Adherence Report Scale (DMARS-4) adapted to measure adherence to analgesic regimen among cancer patients. METHODS: The validated English version of the Medication Adherence Report Scale was translated...

  13. Decommissioning economic risk advisor: DERAD Version 1.0 user's manual. Final report

    International Nuclear Information System (INIS)

    Gjerde, A.R.; Qian, M.; Govil, P.; Balson, W.E.

    1995-04-01

    DERAD - Decommissioning Economic and Risk ADvisor - is a decision support tool designed to help utility decision makers analyze economics and financial risk of decommissioning nuclear power plants. Your current copy of DERAD, Version 1.0, is customized for PWR configurated plants. DERAD has been developed by Decision Focus Incorporated under EPRI sponsorship. If you have ideas or recommendations for how we can improve and enhance future versions of DERAD, we would like to hear from you

  14. U.S. EPA River Reach File Version 1.0

    Data.gov (United States)

    Kansas Data Access and Support Center — Reach File Version 1.0 (RF1) is a vector database of approximately 700,000 miles of streams and open waters in the conterminous United States. It is used extensively...

  15. FORECAST: Regulatory effects cost analysis software manual -- Version 4.1. Revision 1

    International Nuclear Information System (INIS)

    Lopez, B.; Sciacca, F.W.

    1996-07-01

    The FORECAST program was developed to facilitate the preparation of the value-impact portion of NRC regulatory analyses. This PC program integrates the major cost and benefit considerations that may result from a proposed regulatory change. FORECAST automates much of the calculations typically needed in a regulatory analysis and thus reduces the time and labor required to perform these analyses. More importantly, its integrated and consistent treatment of the different value-impact considerations should help assure comprehensiveness, uniformity, and accuracy in the preparation of NRC regulatory analyses. The Current FORECAST Version 4.1 has been upgraded from the previous version and now includes an uncertainty package, an automatic cost escalation package, and other improvements. In addition, it now explicitly addresses public health impacts, occupational health impacts, onsite property damage, and government costs. Thus, FORECAST Version 4.1 can treat all attributes normally quantified in a regulatory analysis

  16. Transfer and development of the PC version of ABAQUS program

    International Nuclear Information System (INIS)

    Li Xiaofeng; Zhu Yuqiao

    1998-01-01

    The transfer and development of the PC version of ABAQUS,a large nonlinear mechanical finite element analysis program, are carried out. Some special problem such as difference of the floating data format in different computers and the computer's unusual dead halt during the data transfer is solved and the visualized I/O capability is added in the redevelopment. Thus, by utilizing the visual capability, the intensity of analysis works is reduced, and the correctness of analysis is ensured. The PC ABAQUS are tested by the standard examples from VAX version of ABAQUS and the calculation results are correct. The results of calculation of stress and deformation for CEFR shell structure with PC ABAQUS and ADINA codes agree very well

  17. Why are there different versions of the Oswestry Disability Index?

    Science.gov (United States)

    Fairbank, Jeremy C T

    2014-01-01

    This article updates readers on the current state of the Oswestry Disability Index (ODI) and the impact of unvalidated versions. The ODI is now licensed to the Mapi Research Trust in order to preserve a standard version in English and in validated translations. A proposed threshold of "normality" is potentially helpful as an outcome for both audit and research. There is an application of the sex section as a quality measure in Germany. The ODI is an important international shared resource for clinicians and investigators and should not be abused. Its current status will not be enhanced by further modification. It is now registered with the International Consortium for Health Outcomes Measurement as a standard outcome measure.

  18. BOT3P - Bologna Transport Analysis Pre-Post-Processors Version 3.0

    International Nuclear Information System (INIS)

    Orsi, Roberto

    2004-01-01

    BOT3P is a set of standard FORTRAN 77 language programs developed at the ENEA-Bologna Nuclear Data Centre. BOT3P Version 1.0 was originally conceived to give the users of the DORT and TORT deterministic transport codes some useful diagnostic tools to prepare and to check their input data files. BOT3P Version 3.0 contains some important additions in the input geometrical model description, such as 'rod' and 'hexagonal' geometrical objects, respecting the exact cross-sectional area value and very suitable to describe a reactor lattice in detail. Moreover, it has extended the possibility to produce the geometrical, material distribution, and fixed neutron source data for the deterministic transport codes TWODANT and THREEDANT of the DANTSYS system and for the PARTISN code too, starting from the same input to BOT3P. When users require X-Y-Z TORT/THREEDANT/PARTISN mesh grids to be generated, BOT3P Version 3.0 produces a geometrical input for the MCNP Monte Carlo transport code also, where the MCNP cells correspond to the X-Y-Z bodies created for TORT.BOT3P Version 3.0 lets users specify areas/volumes of the model where the zone/material distribution can be defined not only by a combinatorial geometry but also by an external source, such as one originated from computerized tomography scan data (only for three-dimensional applications) and from one or more external DORT/TORT input files. BOT3P was developed on a DIGITAL UNIX ALPHA 500/333 workstation and successfully used in some complex neutron shielding and criticality benchmarks. It was also tested on Red Hat Linux 7.1 and is designed to run on most UNIX platforms. All BOT3P versions are publicly available from the Organisation for Economic Co-operation and Development/Nuclear Energy Agency Data Bank (NEA-1627, NEA-1678)

  19. Psychometric properties of the Serbian version of the Empathy Quotient (S-EQ

    Directory of Open Access Journals (Sweden)

    Dimitrijević Aleksandar

    2012-01-01

    Full Text Available In the present study we examined psychometric properties of the Serbian translation of the Empathy Quotient scale (S-EQ. The translated version of the EQ was applied on a sample of 694 high-school students. A sub-sample consisting of 375 high-school students also completed the Interpersonal Reactivity Index (IRI, another widely used empathy measure. The following statistical analyses were applied: internal consistency analysis, explanatory (EFA and confirmatory (CFA factor analyses, and factor congruence analysis. Correlation with IRI and gender differences were calculated to demonstrate validity of the instrument. Results show that the Serbian 40-item version of EQ has lower reliability (Cronbach’s alpha = .782 than the original. The originally proposed one factor structure of the instrument was not confirmed. The short version with 28 items showed better reliablity (alpha= .807. The three-factor solution (cognitive empathy, emotional reactivity, and social skills showed good cross-sample stability (Tucker congruence coefficient over .8 but the results of CFA confirmed the solution proposed in the reviewed literature only partially. The mean scores are similar to those obtained in the other studies, and, as expected, women have significantly higher scores than men. Correlations with all subscales of IRI are statistically significant for the first two subscales of EQ, but not for the „social skills.” We concluded that the Serbian version of the „Empathy Quotient” is a useful research tool which can contribute to cross-cultural studies of empathy, although its psychometric characteristics are not as good as those obtained in the original study. We also suggest that a 28-item should be used preferably to the original 40-item version. [Projekat Ministarstva nauke Republike Srbije, br. 179018: Identification, measurement and development of cognitive and emotional competences important for a society oriented to European integrations

  20. Improved Temperature Sounding and Quality Control Methodology Using AIRS/AMSU Data: The AIRS Science Team Version 5 Retrieval Algorithm

    Science.gov (United States)

    Susskind, Joel; Blaisdell, John M.; Iredell, Lena; Keita, Fricky

    2009-01-01

    This paper describes the AIRS Science Team Version 5 retrieval algorithm in terms of its three most significant improvements over the methodology used in the AIRS Science Team Version 4 retrieval algorithm. Improved physics in Version 5 allows for use of AIRS clear column radiances in the entire 4.3 micron CO2 absorption band in the retrieval of temperature profiles T(p) during both day and night. Tropospheric sounding 15 micron CO2 observations are now used primarily in the generation of clear column radiances .R(sub i) for all channels. This new approach allows for the generation of more accurate values of .R(sub i) and T(p) under most cloud conditions. Secondly, Version 5 contains a new methodology to provide accurate case-by-case error estimates for retrieved geophysical parameters and for channel-by-channel clear column radiances. Thresholds of these error estimates are used in a new approach for Quality Control. Finally, Version 5 also contains for the first time an approach to provide AIRS soundings in partially cloudy conditions that does not require use of any microwave data. This new AIRS Only sounding methodology, referred to as AIRS Version 5 AO, was developed as a backup to AIRS Version 5 should the AMSU-A instrument fail. Results are shown comparing the relative performance of the AIRS Version 4, Version 5, and Version 5 AO for the single day, January 25, 2003. The Goddard DISC is now generating and distributing products derived using the AIRS Science Team Version 5 retrieval algorithm. This paper also described the Quality Control flags contained in the DISC AIRS/AMSU retrieval products and their intended use for scientific research purposes.