WorldWideScience

Sample records for narrow dose range

  1. Dose evaluation of narrow-beam

    International Nuclear Information System (INIS)

    Goto, Shinichi

    1999-01-01

    Reliability of the dose from the narrow photon beam becomes more important since the single high-dose rate radiosurgery becoming popular. The dose evaluation for the optimal dose is difficult due to absence of lateral electronic equilibrium. Data necessary for treatment regimen are TMR (tissue maximum ratio), OCR (off center ratio) and S c,p (total scatter factor). The narrow-beam was 10 MV X-ray from Varian Clinac 2100C equipped with cylindrical Fischer collimator CBI system. Detection was performed by Kodak XV-2 film, a PTW natural diamond detector M60003, Scanditronics silicon detector EDD-5 or Fujitec micro-chamber FDC-9.4C. Phantoms were the water equivalent one (PTW, RW3), water one (PTW, MP3 system) and Wellhofer WP600 system. Factors above were actually measured to reveal that in the dose evaluation of narrow photon beam, TMR should be measured by micro-chamber, OCR, by film, and S c,p , by the two. The use of diamond detector was recommended for more precise measurement and evaluation of the dose. The importance of water phantom in the radiosurgery system was also shown. (K.H.)

  2. Eilat virus displays a narrow mosquito vector range.

    Science.gov (United States)

    Nasar, Farooq; Haddow, Andrew D; Tesh, Robert B; Weaver, Scott C

    2014-12-17

    Most alphaviruses are arthropod-borne and utilize mosquitoes as vectors for transmission to susceptible vertebrate hosts. This ability to infect both mosquitoes and vertebrates is essential for maintenance of most alphaviruses in nature. A recently characterized alphavirus, Eilat virus (EILV), isolated from a pool of Anopheles coustani s.I. is unable to replicate in vertebrate cell lines. The EILV host range restriction occurs at both attachment/entry as well as genomic RNA replication levels. Here we investigated the mosquito vector range of EILV in species encompassing three genera that are responsible for maintenance of other alphaviruses in nature. Susceptibility studies were performed in four mosquito species: Aedes albopictus, A. aegypti, Anopheles gambiae, and Culex quinquefasciatus via intrathoracic and oral routes utilizing EILV and EILV expressing red fluorescent protein (-eRFP) clones. EILV-eRFP was injected at 10(7) PFU/mL to visualize replication in various mosquito organs at 7 days post-infection. Mosquitoes were also injected with EILV at 10(4)-10(1) PFU/mosquito and virus replication was measured via plaque assays at day 7 post-infection. Lastly, mosquitoes were provided bloodmeals containing EILV-eRFP at doses of 10(9), 10(7), 10(5) PFU/mL, and infection and dissemination rates were determined at 14 days post-infection. All four species were susceptible via the intrathoracic route; however, replication was 10-100 fold less than typical for most alphaviruses, and infection was limited to midgut-associated muscle tissue and salivary glands. A. albopictus was refractory to oral infection, while A. gambiae and C. quinquefasciatus were susceptible only at 10(9) PFU/mL dose. In contrast, A. aegypti was susceptible at both 10(9) and 10(7) PFU/mL doses, with body infection rates of 78% and 63%, and dissemination rates of 26% and 8%, respectively. The exclusion of vertebrates in its maintenance cycle may have facilitated the adaptation of EILV to a single

  3. Narrow resonances and short-range interactions

    International Nuclear Information System (INIS)

    Gelman, Boris A.

    2009-01-01

    Narrow resonances in systems with short-range interactions are discussed in an effective field theory (EFT) framework. An effective Lagrangian is formulated in the form of a combined expansion in powers of a momentum Q 0 | 0 --a resonance peak energy. At leading order in the combined expansion, a two-body scattering amplitude is the sum of a smooth background term of order Q 0 and a Breit-Wigner term of order Q 2 (δε) -1 which becomes dominant for δε 3 . Such an EFT is applicable to systems in which short-distance dynamics generates a low-lying quasistationary state. The EFT is generalized to describe a narrow low-lying resonance in a system of charged particles. It is shown that in the case of Coulomb repulsion, a two-body scattering amplitude at leading order in a combined expansion is the sum of a Coulomb-modified background term and a Breit-Wigner amplitude with parameters renormalized by Coulomb interactions.

  4. Volume dips; spot price ranges narrow

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    This article is the September 1994 uranium market summary. Volume in the spot concentrates market fell below 1 million lbs U3O8. In total, twelve deals took place compared to 28 deals in August. Of the twelve deals, three took place in the spot concentrates market, two took place in the medium and long-term market, three in the conversion market, and four in the enrichment market. Restricted prices weakened, but unrestricted prices firmed slightly. The enrichment price range narrowed a bit

  5. Dose calculations algorithm for narrow heavy charged-particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Barna, E A; Kappas, C [Department of Medical Physics, School of Medicine, University of Patras (Greece); Scarlat, F [National Institute for Laser and Plasma Physics, Bucharest (Romania)

    1999-12-31

    The dose distributional advantages of the heavy charged-particles can be fully exploited by using very efficient and accurate dose calculation algorithms, which can generate optimal three-dimensional scanning patterns. An inverse therapy planning algorithm for dynamically scanned, narrow heavy charged-particle beams is presented in this paper. The irradiation `start point` is defined at the distal end of the target volume, right-down, in a beam`s eye view. The peak-dose of the first elementary beam is set to be equal to the prescribed dose in the target volume, and is defined as the reference dose. The weighting factor of any Bragg-peak is determined by the residual dose at the point of irradiation, calculated as the difference between the reference dose and the cumulative dose delivered at that point of irradiation by all the previous Bragg-peaks. The final pattern consists of the weighted Bragg-peaks irradiation density. Dose distributions were computed using two different scanning steps equal to 0.5 mm, and 1 mm respectively. Very accurate and precise localized dose distributions, conform to the target volume, were obtained. (authors) 6 refs., 3 figs.

  6. Low acclimation capacity of narrow-ranging thermal specialists exposes susceptibility to global climate change.

    Science.gov (United States)

    Markle, Tricia M; Kozak, Kenneth H

    2018-05-01

    Thermal acclimation is hypothesized to offer a selective advantage in seasonal habitats and may underlie disparities in geographic range size among closely-related species with similar ecologies. Understanding this relationship is also critical for identifying species that are more sensitive to warming climates. Here, we study North American plethodontid salamanders to investigate whether acclimation ability is associated with species' latitudinal extents and the thermal range of the environments they inhabit. We quantified variation in thermal physiology by measuring standard metabolic rate (SMR) at different test and acclimation temperatures for 16 species of salamanders with varying latitudinal extents. A phylogenetically-controlled Markov chain Monte Carlo generalized linear mixed model (MCMCglmm) was then employed to determine whether there are differences in SMR between wide- and narrow-ranging species at different acclimation temperatures. In addition, we tested for a relationship between the acclimation ability of species and the environmental temperature ranges they inhabit. Further, we investigated if there is a trade-off between critical thermal maximum (CTMax) and thermal acclimation ability. MCMCglmm results show a significant difference in acclimation ability between wide and narrow-ranging temperate salamanders. Salamanders with wide latitudinal distributions maintain or slightly increase SMR when subjected to higher test and acclimation temperatures, whereas several narrow-ranging species show significant metabolic depression. We also found significant, positive relationships between acclimation ability and environmental thermal range, and between acclimation ability and CTMax. Wide-ranging salamander species exhibit a greater capacity for thermal acclimation than narrow-ranging species, suggesting that selection for acclimation ability may have been a key factor enabling geographic expansion into areas with greater thermal variability. Further

  7. The effect of electron collimator leaf shape on the build-up dose in narrow electron MLC fields

    International Nuclear Information System (INIS)

    Vatanen, T; Vaeaenaenen, A; Lahtinen, T; Traneus, E

    2009-01-01

    Previously, we have found that the build-up dose from abutting narrow electron beams formed with unfocussed electron multi-leaf collimator (eMLC) steal leaves was higher than with the respective open field. To investigate more closely the effect of leaf material and shape on dose in the build-up region, straight, round (radius 1.5 cm) and leaf ends with a different front face angle of α (leaf front face pointing towards the beam axis at an angle of 90 - α) made of steel, brass and tungsten were modelled using the BEAMnrc code. Based on a treatment head simulation of a Varian 2100 C/D linac, depth-dose curves and profiles in water were calculated for narrow 6, 12 and 20 MeV eMLC beams (width 1.0 cm, length 10 cm) at source-to-surface distances (SSD) of 102 and 105 cm. The effects of leaf material and front face angle were evaluated based on electron fluence, angle and energy spectra. With a leaf front face angle of 15 deg., the dose in the build-up region of the 6 MeV field varied between 91 and 100%, while for straight and round leaf shapes the dose varied between 89 and 100%. The variation was between 94 and 100% for 12 and 20 MeV. For abutting narrow 6 MeV fields with total field size 5 x 10 cm 2 , the build-up doses at 5 mm depth for the face angle 15 deg. and straight and round leaf shapes were 96% and 86% (SSD 102 cm) and 89% and 85% (SSD 105 cm). With higher energies, the effect of eMLC leaf shape on dose at 5 mm was slight (3-4% units with 12 MeV) and marginal with 20 MeV. The fluence, energy and angle spectra for total and leaf scattered electrons were practically the same for different leaf materials with 6 MeV. With high energies, the spectra for tungsten were more peaked due to lower leaf transmission. Compared with straight leaf ends, the face angle of 15 deg. and round leaf ends led to a 1 mm (for 6 MeV) and between 1 and 5 mm (12 and 20 MeV at a SSD of 105 cm) decrease of therapeutic range and increase of the field size, respectively. However

  8. Comparison of measured and calculated doses for narrow MLC defined fields

    International Nuclear Information System (INIS)

    Lydon, J.; Rozenfeld, A.; Lerch, M.

    2002-01-01

    Full text: The introduction of Intensity Modulated Radiotherapy (IMRT) has led to the use of narrow fields in the delivery of radiation doses to patients. Such fields are not well characterized by calculation methods commonly used in radiotherapy treatment planning systems. The accuracy of the dose calculation algorithm must therefore be investigated prior to clinical use. This study looked at symmetrical and asymmetrical 0.1 to 3cm wide fields delivered with a Varian CL2100C 6MV photon beam. Measured doses were compared to doses calculated using Pinnacle, the ADAC radiotherapy treatment planning system. Two high resolution methods of measuring dose were used. A MOSFET detector in a water phantom and radiographic film in a solid water phantom with spatial resolutions of 10 and 89μm respectively. Dose calculations were performed using the collapsed cone convolution algorithm in Pinnacle with a 0.1cm dose calculation grid in the MLC direction. The effect of Pinnacle not taking into account the rounded leaf ends was simulated by offsetting the leaves by 0.1cm in the dose calculation. Agreement between measurement and calculation is good for fields of 1cm and wider. However, fields of less than 1cm width can show a significant difference between measurement and calculation

  9. Dosimetry of narrow band UVB treatments

    International Nuclear Information System (INIS)

    Goode, D.H.; Mannering, D.M.

    1996-01-01

    Full text: For many years psoriasis has been treated with broad band UVB lamps. These lamps have a bell shaped spectrum which peaks at 305 nm and extends from 280 nm to 350 nm. However research with monochromatic UV radiation has shown that wavelengths between 300 nm and 320 nm are the most efficacious for clearing psoriasis while wavelengths below 305 nm are most effective for producing the undesirable side effect of erythema (sunburn). In response to these findings Philips developed a narrow band UVB tube in which a large fraction of the output was confined to a narrow peak (bandwidth 2.5 nm) situated at 311 nm. Christchurch Hospital replaced broad band UVB with narrow band treatments in August 1995 and as this required UV exposures to be substantially increased new protocols had to be developed. Three aspects needed to be addressed. These were translating the dose from broad band to narrow band for current patients, determining the initial dose for new patients and developing a formula for increasing subsequent exposures to both types of patient. To translate doses the spectral irradiance (μW/cm 2 /nm) that would fall on the patient was measured in both the old broad band and the new narrow band treatment units and from this UV doses were calculated. All doses were expressed in mJ/cm 2 of unweighted UV over the range 250 nm to 400 nm. The erythemal effectiveness of the two units were compared by using the CIE 1987 curve to express doses in terms of the equivalent exposure of monochromatic 297 nm radiation. It was found that an exposure of 3.96 mJ/cm 2 from the broad band FS40 tubes and 12.79 mJ/cm 2 from the narrow band TL/01 tubes were both equivalent to 1.00 mJ/cm 2 of monochromatic 297 nm radiation so when transferring patients all broad band doses needed to be increased by a factor of 3.2. Before transferring any patients this factor was confirmed by conducting two minimal erythema dose (MED) tests on a normal subject, one in each unit. For new patients a

  10. Design of narrow band photonic filter with compact MEMS for tunable resonant wavelength ranging 100 nm

    Directory of Open Access Journals (Sweden)

    Guanquan Liang

    2011-12-01

    Full Text Available A prototype of planar silicon photonic structure is designed and simulated to provide narrow resonant line-width (∼2 nm in a wide photonic band gap (∼210 nm with broad tunable resonant wavelength range (∼100 nm around the optical communication wavelength 1550 nm. This prototype is based on the combination of two modified basic photonic structures, i.e. a split tapered photonic crystal micro-cavity embedded in a photonic wire waveguide, and a slot waveguide with narrowed slabs. This prototype is then further integrated with a MEMS (microelectromechanical systems based electrostatic comb actuator to achieve “coarse tune” and “fine tune” at the same time for wide range and narrow-band filtering and modulating. It also provides a wide range tunability to achieve the designed resonance even fabrication imperfection occurs.

  11. Experimental determination of the lateral dose response functions of detectors to be applied in the measurement of narrow photon-beam dose profiles.

    Science.gov (United States)

    Poppinga, D; Meyners, J; Delfs, B; Muru, A; Harder, D; Poppe, B; Looe, H K

    2015-12-21

    This study aims at the experimental determination of the detector-specific 1D lateral dose response function K(x) and of its associated rotational symmetric counterpart K(r) for a set of high-resolution detectors presently used in narrow-beam photon dosimetry. A combination of slit-beam, radiochromic film, and deconvolution techniques served to accomplish this task for four detectors with diameters of their sensitive volumes ranging from 1 to 2.2 mm. The particular aim of the experiment was to examine the existence of significant negative portions of some of these response functions predicted by a recent Monte-Carlo-simulation (Looe et al 2015 Phys. Med. Biol. 60 6585-607). In a 6 MV photon slit beam formed by the Siemens Artiste collimation system and a 0.5 mm wide slit between 10 cm thick lead blocks serving as the tertiary collimator, the true cross-beam dose profile D(x) at 3 cm depth in a large water phantom was measured with radiochromic film EBT3, and the detector-affected cross-beam signal profiles M(x) were recorded with a silicon diode, a synthetic diamond detector, a miniaturized scintillation detector, and a small ionization chamber. For each detector, the deconvolution of the convolution integral M(x)  =  K(x)  ∗  D(x) served to obtain its specific 1D lateral dose response function K(x), and K(r) was calculated from it. Fourier transformations and back transformations were performed using function approximations by weighted sums of Gaussian functions and their analytical transformation. The 1D lateral dose response functions K(x) of the four types of detectors and their associated rotational symmetric counterparts K(r) were obtained. Significant negative curve portions of K(x) and K(r) were observed in the case of the silicon diode and the diamond detector, confirming the Monte-Carlo-based prediction (Looe et al 2015 Phys. Med. Biol. 60 6585-607). They are typical for the perturbation of the secondary electron field by a detector with

  12. Narrow beam dosimetry for high-energy hadrons and electrons

    CERN Document Server

    Pelliccioni, M; Ulrici, Luisa

    2001-01-01

    Organ doses and effective dose were calculated with the latest version of the Monte Carlo transport code FLUKA in the case of an anthropomorphic mathematical model exposed to monoenergetic narrow beams of protons, pions and electrons in the energy range 10°— 400 GeV. The target organs considered were right eye, thyroid, thymus, lung and breast. Simple scaling laws to the calculated values are given. The present data and formula should prove useful for dosimetric estimations in case of accidental exposures to high-energy beams.

  13. A protein-dye hybrid system as a narrow range tunable intracellular pH sensor.

    Science.gov (United States)

    Anees, Palapuravan; Sudheesh, Karivachery V; Jayamurthy, Purushothaman; Chandrika, Arunkumar R; Omkumar, Ramakrishnapillai V; Ajayaghosh, Ayyappanpillai

    2016-11-18

    Accurate monitoring of pH variations inside cells is important for the early diagnosis of diseases such as cancer. Even though a variety of different pH sensors are available, construction of a custom-made sensor array for measuring minute variations in a narrow biological pH window, using easily available constituents, is a challenge. Here we report two-component hybrid sensors derived from a protein and organic dye nanoparticles whose sensitivity range can be tuned by choosing different ratios of the components, to monitor the minute pH variations in a given system. The dye interacts noncovalently with the protein at lower pH and covalently at higher pH, triggering two distinguishable fluorescent signals at 700 and 480 nm, respectively. The pH sensitivity region of the probe can be tuned for every unit of the pH window resulting in custom-made pH sensors. These narrow range tunable pH sensors have been used to monitor pH variations in HeLa cells using the fluorescence imaging technique.

  14. Analytical probabilistic proton dose calculation and range uncertainties

    Science.gov (United States)

    Bangert, M.; Hennig, P.; Oelfke, U.

    2014-03-01

    We introduce the concept of analytical probabilistic modeling (APM) to calculate the mean and the standard deviation of intensity-modulated proton dose distributions under the influence of range uncertainties in closed form. For APM, range uncertainties are modeled with a multivariate Normal distribution p(z) over the radiological depths z. A pencil beam algorithm that parameterizes the proton depth dose d(z) with a weighted superposition of ten Gaussians is used. Hence, the integrals ∫ dz p(z) d(z) and ∫ dz p(z) d(z)2 required for the calculation of the expected value and standard deviation of the dose remain analytically tractable and can be efficiently evaluated. The means μk, widths δk, and weights ωk of the Gaussian components parameterizing the depth dose curves are found with least squares fits for all available proton ranges. We observe less than 0.3% average deviation of the Gaussian parameterizations from the original proton depth dose curves. Consequently, APM yields high accuracy estimates for the expected value and standard deviation of intensity-modulated proton dose distributions for two dimensional test cases. APM can accommodate arbitrary correlation models and account for the different nature of random and systematic errors in fractionated radiation therapy. Beneficial applications of APM in robust planning are feasible.

  15. Gas-filled cell as a narrow bandwidth bandpass filter in the VUV wavelength range

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-04-15

    We propose a method for spectrally filtering radiation in the VUV wavelength range by means of a monochromator constituted by a cell filled with a resonantly absorbing rare gas. Around particular wavelengths, the gas exhibits narrow-bandwidth absorbing resonances following the Fano profile. In particular, within the photon energy range 60 eV-65 eV, the correlation index of the Fano profiles for the photoionization spectra in Helium is equal to unity, meaning that the minimum of the cross-section is exactly zero. For sufficiently large column density in the gas cell, the spectrum of the incoming radiation will be attenuated by the background cross-section of many orders of magnitude, except for those wavelengths close to the point where the cross-section is zero. Remarkable advantages of a gas monochromator based on this principle are simplicity, efficiency and narrow-bandwidth. A gas monochromator installed in the experimental hall of a VUV SASE FEL facility would enable the delivery of a single-mode VUV laser beam. The design is identical to that of already existing gas attenuator systems for VUV or X-ray FELs. We present feasibility study and exemplifications for the FLASH facility in the VUV regime. (orig.)

  16. The narrow range of perceived predation: a 19 group study

    Directory of Open Access Journals (Sweden)

    Olivier Mesly

    2013-05-01

    Full Text Available This paper rests largely on the works of Mesly (1999 to 2012. It argues that the phenomenon of perceived predation as a functional behavioural phenomenon is subjected to certain limits, a finding based on studies performed on 19 different groups spread over a four-year span. It also finds a constant of k = 1.3 which reflects the invariant nature of perceived predation. These findings add to the theory of financial predation which stipulates that financial predators operate below the limits of detection pertaining to their customers (and market regulators. They are experts at minimizing the perception that clients could have that they are after their money, causing them financial harm, by surprise (perceived predation. Understanding the narrow range in which financial predators operate is setting the grounds to offer better protection to investors and to implementing better control and punitive measures.

  17. Narrow-line external cavity diode laser micro-packaging in the NIR and MIR spectral range

    Science.gov (United States)

    Jiménez, A.; Milde, T.; Staacke, N.; Aßmann, C.; Carpintero, G.; Sacher, J.

    2017-07-01

    Narrow-linewidth tunable diode lasers are an important tool for spectroscopic instrumentation. Conventional external cavity diode lasers offer high output power and narrow linewidth. However, most external cavity diode lasers are designed as laboratory instrument and do not allow portability. In comparison, other commonly used lasers, like distributed feedback lasers (DFB) that are capable of driving a handheld device, are limited in power and show linewidths which are not sufficiently narrow for certain applications. We present new miniaturized types of tunable external cavity diode laser which overcome the drawbacks of conventional external cavity diode lasers and which preserve the advantages of this laser concept. Three different configurations are discussed in this article. The three types of miniaturized external cavity diode laser systems achieve power values of more than 50 mW within the 1.4 μm water vapor absorption band with excellent side-mode suppression and linewidth below 100 kHz. Typical features outstand with respect to other type of laser systems which are of extended use such as DFB laser diodes. The higher output power and the lower linewidth will enable a higher sensitivity and resolution for a wide range of applications.

  18. Evidence Based Digoxin Therapeutic Monitoring - A Lower and Narrower Therapeutic Range

    Directory of Open Access Journals (Sweden)

    Amine BENLMOUDEN

    2016-06-01

    Full Text Available Cardiac glycosides have been used for congestive heart failure and certain cardiac arrhythmias for more than 200 years. Despite the introduction of a variety of new classes of drugs for the management of heart failure, specifically angiotensin-converting enzyme (ACE inhibitors, b-adrenergic antagonists (bblockers, and the aldosterone antagonist spironolactone, digoxin continues to have an important role in long-term outpatient management. However, a narrow margin exists between therapeutic and toxic doses of digoxin, resulting in a high incidence of digoxin toxicity in clinical practice.A wide variety of placebo-controlled clinical trials have unequivocally shown that treatment with digoxin can improve symptoms, quality of life, and exercise tolerance in patients with mild, moderate, or severe heart failure. The clinical relevance of digoxin therapeutic monitoring is also proved but the SDC (Serum Digoxin Conentrations required for optimal clinical efficacy and acceptable toxicity remains controversial. In the last years, international guidelines recommend 1.2 ng/mL as acceptable high level.In this bibliographic synthesis, we aim to collect pertinent informations from MedLine database about exposure-effect relationship in order to assess the evidence level scientific of new digoxin therapeutic monitoring. 

  19. Narrow pH Range of Surface Water Bodies Receiving Pesticide Input in Europe.

    Science.gov (United States)

    Bundschuh, Mirco; Weyers, Arnd; Ebeling, Markus; Elsaesser, David; Schulz, Ralf

    2016-01-01

    Fate and toxicity of the active ingredients (AI's) of plant protection products in surface waters is often influenced by pH. Although a general range of pH values is reported in literature, an evaluation targeting aquatic ecosystems with documented AI inputs is lacking at the larger scale. Results show 95% of European surface waters (n = 3075) with a documented history of AI exposure fall within a rather narrow pH range, between 7.0 and 8.5. Spatial and temporal variability in the data may at least be partly explained by the calcareous characteristics of parental rock material, the affiliation of the sampling site to a freshwater ecoregion, and the photosynthetic activity of macrophytes (i.e., higher pH values with photosynthesis). Nonetheless, the documented pH range fits well with the standard pH of most ecotoxicological test guidelines, confirming the fate and ecotoxicity of AIs are usually adequately addressed.

  20. High-temperature absorbed dose measurements in the megagray range

    International Nuclear Information System (INIS)

    Balian, P.; Ardonceau, J.; Zuppiroli, L.

    1988-01-01

    Organic conductors of the tetraselenotetracene family have been tested as ''high-temperature'' absorbed dose dosimeters. They were heated up to 120 0 C and irradiated at this temperature with 1-MeV electrons in order to simulate, in a short time, a much longer γ-ray irradiation. The electric resistance increase of the crystal can be considered a good measurement of the absorbed dose in the range 10 6 Gy to a few 10 8 Gy and presumably one order of magnitude more. This dosimeter also permits on-line (in-situ) measurements of the absorbed dose without removing the sensor from the irradiation site. The respective advantages of organic and inorganic dosimeters at these temperature and dose ranges are also discussed. In this connection, we outline new, but negative, results concerning the possible use of silica as a high-temperature, high-dose dosimeter. (author)

  1. Low-dose narrow-band UVB phototherapy combined with topical therapy is effective in psoriasis and does not inhibit systemic T-cell activation

    NARCIS (Netherlands)

    de Rie, M. A.; Out, T. A.; Bos, J. D.

    1998-01-01

    Psoriasis is a chronic T-cell-mediated inflammatory skin disease which can be treated with topical medication, phototherapy or systemic medication. A subgroup of psoriatic patients does not respond to monotherapy and needs combination therapy. We used low-dose narrow-band UVB phototherapy, combined

  2. Effective dose range for dental cone beam computed tomography scanners

    International Nuclear Information System (INIS)

    Pauwels, Ruben; Beinsberger, Jilke; Collaert, Bruno; Theodorakou, Chrysoula; Rogers, Jessica; Walker, Anne; Cockmartin, Lesley; Bosmans, Hilde; Jacobs, Reinhilde; Bogaerts, Ria; Horner, Keith

    2012-01-01

    Objective: To estimate the absorbed organ dose and effective dose for a wide range of cone beam computed tomography scanners, using different exposure protocols and geometries. Materials and methods: Two Alderson Radiation Therapy anthropomorphic phantoms were loaded with LiF detectors (TLD-100 and TLD-100H) which were evenly distributed throughout the head and neck, covering all radiosensitive organs. Measurements were performed on 14 CBCT devices: 3D Accuitomo 170, Galileos Comfort, i-CAT Next Generation, Iluma Elite, Kodak 9000 3D, Kodak 9500, NewTom VG, NewTom VGi, Pax-Uni3D, Picasso Trio, ProMax 3D, Scanora 3D, SkyView, Veraviewepocs 3D. Effective dose was calculated using the ICRP 103 (2007) tissue weighting factors. Results: Effective dose ranged between 19 and 368 μSv. The largest contributions to the effective dose were from the remainder tissues (37%), salivary glands (24%), and thyroid gland (21%). For all organs, there was a wide range of measured values apparent, due to differences in exposure factors, diameter and height of the primary beam, and positioning of the beam relative to the radiosensitive organs. Conclusions: The effective dose for different CBCT devices showed a 20-fold range. The results show that a distinction is needed between small-, medium-, and large-field CBCT scanners and protocols, as they are applied to different indication groups, the dose received being strongly related to field size. Furthermore, the dose should always be considered relative to technical and diagnostic image quality, seeing that image quality requirements also differ for patient groups. The results from the current study indicate that the optimisation of dose should be performed by an appropriate selection of exposure parameters and field size, depending on the diagnostic requirements.

  3. Genome degradation in Brucella ovis corresponds with narrowing of its host range and tissue tropism.

    Directory of Open Access Journals (Sweden)

    Renee M Tsolis

    Full Text Available Brucella ovis is a veterinary pathogen associated with epididymitis in sheep. Despite its genetic similarity to the zoonotic pathogens B. abortus, B. melitensis and B. suis, B. ovis does not cause zoonotic disease. Genomic analysis of the type strain ATCC25840 revealed a high percentage of pseudogenes and increased numbers of transposable elements compared to the zoonotic Brucella species, suggesting that genome degradation has occurred concomitant with narrowing of the host range of B. ovis. The absence of genomic island 2, encoding functions required for lipopolysaccharide biosynthesis, as well as inactivation of genes encoding urease, nutrient uptake and utilization, and outer membrane proteins may be factors contributing to the avirulence of B. ovis for humans. A 26.5 kb region of B. ovis ATCC25840 Chromosome II was absent from all the sequenced human pathogenic Brucella genomes, but was present in all of 17 B. ovis isolates tested and in three B. ceti isolates, suggesting that this DNA region may be of use for differentiating B. ovis from other Brucella spp. This is the first genomic analysis of a non-zoonotic Brucella species. The results suggest that inactivation of genes involved in nutrient acquisition and utilization, cell envelope structure and urease may have played a role in narrowing of the tissue tropism and host range of B. ovis.

  4. TLD personnel monitoring dose estimation- extending the upper limit of the dose range

    International Nuclear Information System (INIS)

    Popli, K.L.; Sathian, Deepa; Divakaran, T.; Massand, O.P.

    2001-01-01

    TLD personnel monitoring was introduced in the year 1975 in India and at present nearly 41,000 radiation workers are being monitored by 13 monitoring laboratories all over India. The BARC- TLD being used for personnel monitoring is based on CaSO 4 :Dy embedded in PTFE and semi-automatic TL reader using hot N 2 Gas for heating the dosimeters. This reader has the range to measure γ dose from ten μSv to 3 μSv and x-ray dose form 1 μ Sv to 0.3 Sv due to the higher sensitivity of CaSO 4 : Dy to lower energy photons (20keV-50 keV) generated by diagnostic x-ray units. The x-ray radiation workers are at present nearly 35% of the total radiation workers monitored and this number is expected to grow as more and more number of x-ray workers are covered under this service. The upper limit of the x-ray dose range of the instrument is 0.3 Sv, whereas in the past one year it has been observed that at least 25% of the total overexposures reported in case of x-ray workers have recorded the dose more than 0.3 Sv. This paper presents the technique developed to extend the upper limit of the range from 0.3 Sv to 1 Sv for x-rays and 10 Sv for γ rays

  5. Fast IMRT with narrow high energy scanned photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Andreassen, Bjoern; Straaring t, Sara Janek; Holmberg, Rickard; Naefstadius, Peder; Brahme, Anders [Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, P.O. Box 260, SE-171 76 Stockholm (Sweden); Department of Hospital Physics, Karolinska University Hospital, SE-171 76 Stockholm (Sweden); Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, P.O. Box 260, SE-171 76 Stockholm, Sweden and Department of Hospital Physics, Karolinska University Hospital, SE-171 76 Stockholm (Sweden)

    2011-08-15

    Purpose: Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in combination with fast penumbra trimming multileaf collimators. Previously, experiments have been performed with full range targets, generating a broad bremsstrahlung beam, in combination with multileaf collimators or material compensators. In the present publication, the first measurements with fast narrow high energy (50 MV) scanned photon beams are presented indicating an interesting performance increase even though some of the hardware used were suboptimal. Methods: Inverse therapy planning was used to calculate optimal scanning patterns to generate dose distributions with interesting properties for fast IMRT. To fully utilize the dose distributional advantages with scanned beams, it is necessary to use narrow high energy beams from a thin bremsstrahlung target and a powerful purging magnet capable of deflecting the transmitted electron beam away from the generated photons onto a dedicated electron collector. During the present measurements the scanning system, purging magnet, and electron collimator in the treatment head of the MM50 racetrack accelerator was used with 3-6 mm thick bremsstrahlung targets of beryllium. The dose distributions were measured with diodes in water and with EDR2 film in PMMA. Monte Carlo simulations with geant4 were used to study the influence of the electrons transmitted through the target on the photon pencil beam kernel. Results: The full width at half-maximum (FWHM) of the scanned photon beam was 34 mm measured at isocenter, below 9.5 cm of water, 1 m from the 3 mm Be bremsstrahlung target. To generate a homogeneous dose distribution in a 10 x 10 cm{sup 2} field, the authors used a spot matrix of 100 equal intensity

  6. Efficacy and Safety of Sarecycline, a Novel, Once-Daily, Narrow Spectrum Antibiotic for the Treatment of Moderate to Severe Facial Acne Vulgaris: Results of a Phase 2, Dose-Ranging Study.

    Science.gov (United States)

    Leyden, James J; Sniukiene, Vilma; Berk, David R; Kaoukhov, Alexandre

    2018-03-01

    There is a need for new oral antibiotics for acne with improved safety profiles and targeted antibacterial spectra. Sarecycline is a novel, tetracycline-class antibiotic specifically designed for acne, offering a narrow spectrum of activity compared with currently available tetracyclines, including less activity against enteric Gram-negative bacteria. This phase 2 study evaluated the efficacy and safety of three doses of sarecycline for moderate to severe facial acne vulgaris. In this multicenter, double-blind, placebo-controlled study, patients aged 12 to 45 years were randomized to once-daily sarecycline 0.75 mg/kg, 1.5 mg/kg, 3.0 mg/kg, or placebo. Efficacy analyses included change from baseline in inflammatory and noninflammatory lesion counts at week 12, with between-group comparisons using analysis of covariance. Safety assessments included adverse events (AEs), clinical laboratories, vital signs, electrocardiograms, and physical examinations. Overall, 285 randomized patients received at least one dose of study drug. At week 12, sarecycline 1.5 mg/kg and 3.0 mg/kg groups demonstrated significantly reduced inflammatory lesions from baseline (52.7% and 51.8%, respectively) versus placebo (38.3%; P=0.02 and P=0.03, respectively). Sarecycline was safe and well tolerated, with similar gastrointestinal AE rates in sarecycline and placebo groups. Vertigo and photosensitivity AEs occurred in less than 1% of patients when pooling sarecycline groups; no vulvovaginal candidiasis AEs occurred. Discontinuation rates due to AEs were low. No serious AEs occurred. Once-daily sarecycline 1.5 mg/kg significantly reduced inflammatory lesions versus placebo and was safe and well tolerated with low rates of AEs, including gastrointestinal AEs. Sarecycline 3.0 mg/kg did not result in additional efficacy versus 1.5 mg/kg. Sarecycline may represent a novel, once-daily treatment for patients with moderate to severe acne. It offers a narrow antibacterial spectrum relative to other

  7. Dose-ranging pharmacokinetics of colistin methanesulphonate (CMS) and colistin in rats following single intravenous CMS doses.

    Science.gov (United States)

    Marchand, Sandrine; Lamarche, Isabelle; Gobin, Patrice; Couet, William

    2010-08-01

    The aim of this study was to evaluate the effect of colistin methanesulphonate (CMS) dose on CMS and colistin pharmacokinetics in rats. Three rats per group received an intravenous bolus of CMS at a dose of 5, 15, 30, 60 or 120 mg/kg. Arterial blood samples were drawn at 0, 5, 15, 30, 60, 90, 120, 150 and 180 min. CMS and colistin plasma concentrations were determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The pharmacokinetic parameters of CMS and colistin were calculated by non-compartmental analysis. Linear relationships were observed between CMS and colistin AUCs to infinity and CMS doses, as well as between CMS and colistin C(max) and CMS doses. CMS and colistin pharmacokinetics were linear for a range of colistin concentrations covering the range of values encountered and recommended in patients even during treatment with higher doses.

  8. Wide-range neutron dose determination with CR-39

    International Nuclear Information System (INIS)

    Arneja, A.R.; Waker, A.J.

    1995-01-01

    Optical density measurements of CR-30 irradiated with 252 Cf neutrons and chemically etched with 6.5 N KOH solution have been used to determine neutron absorbed doses between 0.1 and 10 Gy. Optimum etching conditions will depend upon the absorbed dose. Since it is not always possible to know the range of absorbed dose on a CR-39 dosemeter collected from personnel and area monitor stations in a criticality accident situation, a three-step two-hour chemical etch at 60 o C has been found to be appropriate. If after a total of six hours of chemical etching the optical density is found to be below 0.04 for 500 nm light (transmission > 90%) then further treatment in the form of electrochemical etching can be carried out to determine the lower absorbed dose. In this manner, absorbed doses below 0.1 Gy can be determined by counting tracks over a unit area. (author)

  9. Real-life effectiveness of omalizumab in severe allergic asthma above the recommended dosing range criteria.

    Science.gov (United States)

    Hew, M; Gillman, A; Sutherland, M; Wark, P; Bowden, J; Guo, M; Reddel, H K; Jenkins, C; Marks, G B; Thien, F; Rimmer, J; Katsoulotos, G P; Cook, M; Yang, I; Katelaris, C; Bowler, S; Langton, D; Wright, C; Bint, M; Yozghatlian, V; Burgess, S; Sivakumaran, P; Yan, K Y; Kritikos, V; Peters, M; Baraket, M; Aminazad, A; Robinson, P; Jaffe, A; Powell, H; Upham, J W; McDonald, V M; Gibson, P G

    2016-11-01

    Omalizumab (Xolair) dosing in severe allergic asthma is based on serum IgE and bodyweight. In Australia, patients eligible for omalizumab but exceeding recommended ranges for IgE (30-1500 IU/mL) and bodyweight (30-150 kg) may still receive a ceiling dose of 750 mg/4 weeks. About 62% of patients receiving government-subsidized omalizumab are enrolled in the Australian Xolair Registry (AXR). To determine whether AXR participants above the recommended dosing ranges benefit from omalizumab and to compare their response to within-range participants. Data were stratified according to dose range status (above-range or within-range). Further sub-analyses were conducted according to the reason for being above the dosing range (IgE only vs. IgE and weight). Data for 179 participants were analysed. About 55 (31%) were above recommended dosing criteria; other characteristics were similar to within-range participants. Above-range participants had higher baseline IgE [812 (IQR 632, 1747) IU/mL vs. 209 (IQR 134, 306) IU/mL] and received higher doses of omalizumab [750 (IQR 650, 750) mg] compared to within-range participants [450 (IQR, 300, 600) mg]. At 6 months, improvements in Juniper 5-item Asthma Control Questionnaire (ACQ-5, 3.61 down to 2.01 for above-range, 3.47 down to 1.93 for within-range, P omalizumab have significantly improved symptom control, quality of life and lung function to a similar degree to within-range participants, achieved without dose escalation above 750 mg. © 2016 John Wiley & Sons Ltd.

  10. Evaluation of dose exposure in 64-slice CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M. [University Hospital Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Buchgeister, M.; Klabunde, M. [University of Tuebingen, Institute of Medical Physics, Tuebingen (Germany)

    2007-10-15

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  11. Evaluation of dose exposure in 64-slice CT colonography

    International Nuclear Information System (INIS)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M.; Buchgeister, M.; Klabunde, M.

    2007-01-01

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  12. Vancomycin Dosing in Obese Patients: Special Considerations and Novel Dosing Strategies.

    Science.gov (United States)

    Durand, Cheryl; Bylo, Mary; Howard, Brian; Belliveau, Paul

    2018-06-01

    To review the literature regarding vancomycin pharmacokinetics in obese patients and strategies used to improve dosing in this population. PubMed, EMBASE (1974 to November 2017), and Google Scholar searches were conducted using the search terms vancomycin, obese, obesity, pharmacokinetics, strategy, and dosing. Additional articles were selected from reference lists of selected studies. Included articles were those published in English with a primary focus on vancomycin pharmacokinetic parameters in obese patients and practical vancomycin dosing strategies, clinical experiences, or challenges of dosing vancomycin in this population. Volume of distribution and clearance are the pharmacokinetic parameters that most often affect vancomycin dosing in obese patients; both are increased in this population. Challenges with dosing in obese patients include inconsistent and inadequate dosing, observations that the obese population may not be homogeneous, and reports of an increased likelihood of supratherapeutic trough concentrations. Investigators have revised and developed dosing and monitoring protocols to address these challenges. These approaches improved target trough attainment to varying degrees. Some of the vancomycin dosing approaches provided promising results in obese patients, but there were notable differences in methods used to develop these approaches, and sample sizes were small. Although some approaches can be considered for validation in individual institutions, further research is warranted. This may include validating approaches in larger populations with narrower obesity severity ranges, investigating target attainment in indication-specific target ranges, and evaluating the impact of different dosing weights and methods of creatinine clearance calculation.

  13. Radon Exposure and the Definition of Low Doses-The Problem of Spatial Dose Distribution.

    Science.gov (United States)

    Madas, Balázs G

    2016-07-01

    Investigating the health effects of low doses of ionizing radiation is considered to be one of the most important fields in radiological protection research. Although the definition of low dose given by a dose range seems to be clear, it leaves some open questions. For example, the time frame and the target volume in which absorbed dose is measured have to be defined. While dose rate is considered in the current system of radiological protection, the same cancer risk is associated with all exposures, resulting in a given amount of energy absorbed by a single target cell or distributed among all the target cells of a given organ. However, the biological effects and so the health consequences of these extreme exposure scenarios are unlikely to be the same. Due to the heterogeneous deposition of radon progeny within the lungs, heterogeneous radiation exposure becomes a practical issue in radiological protection. While the macroscopic dose is still within the low dose range, local tissue doses on the order of Grays can be reached in the most exposed parts of the bronchial airways. It can be concluded that progress in low dose research needs not only low dose but also high dose experiments where small parts of a biological sample receive doses on the order of Grays, while the average dose over the whole sample remains low. A narrow interpretation of low dose research might exclude investigations with high relevance to radiological protection. Therefore, studies important to radiological protection should be performed in the frame of low dose research even if the applied doses do not fit in the dose range used for the definition of low doses.

  14. Applichation of the sulphate ceric dosimetric in the high doses range

    International Nuclear Information System (INIS)

    Prieto Miranda, F.

    1991-01-01

    The ceric-cerous dosimetric system is one of the system more employed in the high dose dosimetry. The spectrophotometric procedure to measure the ceric-concentration is an usual analityc method to determine the absorbed dose. On the other hand, due at increase employ of the irradiation process control. In this paper is realized the ceric-cerous dosimetric calibration in the dose range of 0,6 - 5 kGy and the application in the irradiation process control to differents absorbed dose values

  15. Properties of Wide-dose-range GafChromic Films for Synchrotron Radiation Facility

    International Nuclear Information System (INIS)

    Nariyama, Nobuteru

    2007-01-01

    GafChromic films have been used at SPring-8 to detect the intensively irradiated parts and protect them from damage by being covered with shield or moved. To extend the usable dose range more widely, a new type of sensitive film EBT was investigated for the introduction. Calibration curves were obtained irradiated with 60Co γ rays and compared with those of other GafChromic films. For the application, these films were set in the white x-ray hutch and the dose distribution was measured. Ratio of doses given by EBT and XT-R indicated the degree of the photon spectrum hardness, which depended on the positions. As a result, dose range from 50 mGy to 300 kGy became available for dose distribution measurements, and a set of films having different energy responses was found to give information of photon spectra

  16. Technical Note: Scanning of parallel-plate ionization chamber and diamond detector for measurements of water-dose profiles in the vicinity of a narrow x-ray microbeam.

    Science.gov (United States)

    Nariyama, Nobuteru

    2017-12-01

    Scanning of dosimeters facilitates dose distribution measurements with fine spatial resolutions. This paper presents a method of conversion of the scanning results to water-dose profiles and provides an experimental verification. An Advanced Markus chamber and a diamond detector were scanned at a resolution of 6 μm near the beam edges during irradiation with a 25-μm-wide white narrow x-ray beam from a synchrotron radiation source. For comparison, GafChromic films HD-810 and HD-V2 were also irradiated. The conversion procedure for the water dose values was simulated with Monte Carlo photon-electron transport code as a function of the x-ray incidence position. This method was deduced from nonstandard beam reference-dosimetry protocols used for high-energy x-rays. Among the calculated nonstandard beam correction factors, P wall , which is the ratio of the absorbed dose in the sensitive volume of the chamber with water wall to that with a polymethyl methacrylate wall, was found to be the most influential correction factor in most conditions. The total correction factor ranged from 1.7 to 2.7 for the Advanced Markus chamber and from 1.15 to 1.86 for the diamond detector as a function of the x-ray incidence position. The water dose values obtained with the Advanced Markus chamber and the HD-810 film were in agreement in the vicinity of the beam, within 35% and 18% for the upper and lower sides of the beam respectively. The beam width obtained from the diamond detector was greater, and the doses out of the beam were smaller than the doses of the others. The comparison between the Advanced Markus chamber and HD-810 revealed that the dose obtained with the scanned chamber could be converted to the water dose around the beam by applying nonstandard beam reference-dosimetry protocols. © 2017 American Association of Physicists in Medicine.

  17. A wide range survey meter for estimating γ- and β-dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1980-09-01

    A survey meter has been developed to measure β-dose rates in the range 0.1 - 100 rad/h (1 mGy/h - 1 Gy/h) and γ-dose rates in the range 1 mrad/h - 100 rad/h (10 μGy/h-1 Gy/h). It also provides an audible warning of high γ-dose rates and an audible and visible warning when a predetermined γ-dose is exceeded. The report describes the design of the survey meter and presents data measured on the performance of an engineering prototype. Factors which affect performance and have been investigated are temperature, battery voltage (and type of battery), GM counter counting loss, direction of incident radiation, and energy of γ-rays. Finally, the application and calibration of the survey meter are discussed. (auth)

  18. The continual reassessment method: comparison of Bayesian stopping rules for dose-ranging studies.

    Science.gov (United States)

    Zohar, S; Chevret, S

    2001-10-15

    The continual reassessment method (CRM) provides a Bayesian estimation of the maximum tolerated dose (MTD) in phase I clinical trials and is also used to estimate the minimal efficacy dose (MED) in phase II clinical trials. In this paper we propose Bayesian stopping rules for the CRM, based on either posterior or predictive probability distributions that can be applied sequentially during the trial. These rules aim at early detection of either the mis-choice of dose range or a prefixed gain in the point estimate or accuracy of estimated probability of response associated with the MTD (or MED). They were compared through a simulation study under six situations that could represent the underlying unknown dose-response (either toxicity or failure) relationship, in terms of sample size, probability of correct selection and bias of the response probability associated to the MTD (or MED). Our results show that the stopping rules act correctly, with early stopping by using the two first rules based on the posterior distribution when the actual underlying dose-response relationship is far from that initially supposed, while the rules based on predictive gain functions provide a discontinuation of inclusions whatever the actual dose-response curve after 20 patients on average, that is, depending mostly on the accumulated data. The stopping rules were then applied to a data set from a dose-ranging phase II clinical trial aiming at estimating the MED dose of midazolam in the sedation of infants during cardiac catheterization. All these findings suggest the early use of the two first rules to detect a mis-choice of dose range, while they confirm the requirement of including at least 20 patients at the same dose to reach an accurate estimate of MTD (MED). A two-stage design is under study. Copyright 2001 John Wiley & Sons, Ltd.

  19. Large-amplitude and narrow-band vibration phenomenon of a foursquare fix-supported flexible plate in a rigid narrow channel

    Energy Technology Data Exchange (ETDEWEB)

    Liu Lifang, E-mail: liu_lifang1106@yahoo.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Lu Daogang, E-mail: ludaogang@ncepu.edu.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Li Yang, E-mail: qinxiuyi@sina.com [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Zhang Pan, E-mail: zhangpan@ncepu.edu.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China); Niu Fenglei, E-mail: niufenglei@ncepu.edu.cn [School of Nuclear Science and Engineering, North China Electric Power University, Zhuxinzhuang, Dewai, Beijing 102206 (China)

    2011-08-15

    Highlights: > FIV of a foursquare fix-supported flexible plate exposed to axial flow was studied. > Special designed test section and advanced measuring equipments were adopted. > The narrow-band vibration phenomenon with large amplitude was observed. > Line of plate's vibration amplitude and flow rate was investigated. > The phenomenon and the measurement error were analyzed. - Abstract: An experiment was performed to analyze the flow-induced vibration behavior of a foursquare fix-supported flexible plate exposed to the axial flow within a rigid narrow channel. The large-amplitude and narrow-band vibration phenomenon was observed in the experiment when the flow velocity varied with the range of 0-5 m/s. The occurring condition and some characteristics of the large-amplitude and narrow-band vibrations were investigated.

  20. Simplified method for creating a density-absorbed dose calibration curve for the low dose range from Gafchromic EBT3 film

    Directory of Open Access Journals (Sweden)

    Tatsuhiro Gotanda

    2016-01-01

    Full Text Available Radiochromic film dosimeters have a disadvantage in comparison with an ionization chamber in that the dosimetry process is time-consuming for creating a density-absorbed dose calibration curve. The purpose of this study was the development of a simplified method of creating a density-absorbed dose calibration curve from radiochromic film within a short time. This simplified method was performed using Gafchromic EBT3 film with a low energy dependence and step-shaped Al filter. The simplified method was compared with the standard method. The density-absorbed dose calibration curves created using the simplified and standard methods exhibited approximately similar straight lines, and the gradients of the density-absorbed dose calibration curves were −32.336 and −33.746, respectively. The simplified method can obtain calibration curves within a much shorter time compared to the standard method. It is considered that the simplified method for EBT3 film offers a more time-efficient means of determining the density-absorbed dose calibration curve within a low absorbed dose range such as the diagnostic range.

  1. Development of dose monitoring system applicable to various radiations with wide energy ranges

    International Nuclear Information System (INIS)

    Sato, Tatsuhiko; Satoh, Daiki; Endo, Akira; Yamaguchi, Yasuhiro

    2005-01-01

    A new inventive radiation dose monitor, designated as DARWIN (Dose monitoring system Applicable to various Radiations with WIde energy raNges), has been developed for monitoring doses in workspaces and surrounding environments of high energy accelerator facilities. DARWIN is composed of a phoswitch-type scintillation detector, which consists of liquid organic scintillator BC501A coupled with ZnS(Ag) scintillation sheets doped with 6 Li, and a data acquisition system based on a Digital-Storage-Oscilloscope. Scintillations from the detector induced by thermal and fast neutrons, photons and muons were discriminated by analyzing their waveforms, and their light outputs were directly converted into the corresponding doses by applying the G-function method. Characteristics of DARWIN were studied by both calculation and experiment. The calculated results indicate that DARWIN gives reasonable estimations of doses in most radiation fields. It was found from the experiment that DARWIN has an excellent property of measuring doses from all particles that significantly contribute to the doses in surrounding environments of accelerator facilities - neutron, photon and muon with wide energy ranges. The experimental results also suggested that DARWIN enables us to monitor small fluctuation of neutron dose rates near the background-level owing to its high sensitivity. (author)

  2. Rescue dose orders as an alternative to range orders: an evidence-based practice project.

    Science.gov (United States)

    Yi, Cassia

    2015-06-01

    Relief of pain is a fundamental aspect of optimal patient care. However, pain management in the inpatient setting is often constrained by concerns related to regulatory oversight, particularly with regard to the use of opioid dose range orders. These concerns can inadvertently result in the development of policies and practices that can negatively impact the health care team's ability to deliver optimal and individualized pain management. An evidence-based practice project was undertaken to address concerns about regulatory oversight of pain management processes by changing the way pain was managed in a large academic hospital setting. A novel pain management approach using rescue dose medications was established as an alternative to opioid dose range orders. The use of the rescue dose protocol was successfully implemented. Outcomes included an overall reduction in the administration of inappropriate intravenous opioids and opioid-acetaminophen combination medications, with a subsequent increase in single-entity first-line opioid analgesics. Rescue dose protocols may offer an alternative to opioid dose range orders as a means of effectively managing pain. Copyright © 2015 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  3. Feasibility of RACT for 3D dose measurement and range verification in a water phantom

    Energy Technology Data Exchange (ETDEWEB)

    Alsanea, Fahed [School of Health Sciences, Purdue University, 550 Stadium Mall Drive, West Lafayette, Indiana 47907-2051 (United States); Moskvin, Vadim [Radiation Oncology, Indiana University School of Medicine, 535 Barnhill Drive, RT 041, Indianapolis, Indiana 46202-5289 (United States); Stantz, Keith M., E-mail: kstantz@purdue.edu [School of Health Sciences, Purdue University, 550 Stadium Mall Drive, West Lafayette, Indiana 47907-2051 and Radiology and Imaging Sciences, Indiana University School of Medicine, 950 West Walnut Street, Indianapolis, Indiana 46202-5289 (United States)

    2015-02-15

    Purpose: The objective of this study is to establish the feasibility of using radiation-induced acoustics to measure the range and Bragg peak dose from a pulsed proton beam. Simulation studies implementing a prototype scanner design based on computed tomographic methods were performed to investigate the sensitivity to proton range and integral dose. Methods: Derived from thermodynamic wave equation, the pressure signals generated from the dose deposited from a pulsed proton beam with a 1 cm lateral beam width and a range of 16, 20, and 27 cm in water using Monte Carlo methods were simulated. The resulting dosimetric images were reconstructed implementing a 3D filtered backprojection algorithm and the pressure signals acquired from a 71-transducer array with a cylindrical geometry (30 × 40 cm) rotated over 2π about its central axis. Dependencies on the detector bandwidth and proton beam pulse width were performed, after which, different noise levels were added to the detector signals (using 1 μs pulse width and a 0.5 MHz cutoff frequency/hydrophone) to investigate the statistical and systematic errors in the proton range (at 20 cm) and Bragg peak dose (of 1 cGy). Results: The reconstructed radioacoustic computed tomographic image intensity was shown to be linearly correlated to the dose within the Bragg peak. And, based on noise dependent studies, a detector sensitivity of 38 mPa was necessary to determine the proton range to within 1.0 mm (full-width at half-maximum) (systematic error < 150 μm) for a 1 cGy Bragg peak dose, where the integral dose within the Bragg peak was measured to within 2%. For existing hydrophone detector sensitivities, a Bragg peak dose of 1.6 cGy is possible. Conclusions: This study demonstrates that computed tomographic scanner based on ionizing radiation-induced acoustics can be used to verify dose distribution and proton range with centi-Gray sensitivity. Realizing this technology into the clinic has the potential to significantly

  4. Darwin: Dose monitoring system applicable to various radiations with wide energy ranges

    International Nuclear Information System (INIS)

    Sato, T.; Satoh, D.; Endo, A.; Yamaguchi, Y.

    2007-01-01

    A new radiation dose monitor, designated as DARWIN (Dose monitoring system Applicable to various Radiations with Wide energy ranges), has been developed for real-time monitoring of doses in workspaces and surrounding environments of high-energy accelerator facilities. DARWIN is composed of a Phoswitch-type scintillation detector, which consists of liquid organic scintillator BC501A coupled with ZnS(Ag) scintillation sheets doped with 6 Li, and a data acquisition system based on a Digital-Storage-Oscilloscope. DARWIN has the following features: (1) capable of monitoring doses from neutrons, photons and muons with energies from thermal energy to 1 GeV, 150 keV to 100 MeV and 1 MeV to 100 GeV, respectively, (2) highly sensitive with precision and (3) easy to operate with a simple graphical user-interface. The performance of DARWIN was examined experimentally in several radiation fields. The results of the experiments indicated the accuracy and wide response range of DARWIN for measuring dose rates from neutrons, photons and muons with wide energies. It was also found from the experiments that DARWIN enables us to monitor small fluctuations of neutron dose rates near the background level because of its high sensitivity. With these properties, DARWIN will be able to play a very important role for improving radiation safety in high-energy accelerator facilities. (authors)

  5. Optimal Design of a High Efficiency LLC Resonant Converter with a Narrow Frequency Range for Voltage Regulation

    Directory of Open Access Journals (Sweden)

    Junhao Luo

    2018-05-01

    Full Text Available As a key factor in the design of a voltage-adjustable LLC resonant converter, frequency regulation range is very important to the optimization of magnetic components and efficiency improvement. This paper presents a novel optimal design method for LLC resonant converters, which can narrow the frequency variation range and ensure high efficiency under the premise of a required gain achievement. A simplified gain model was utilized to simplify the calculation and the expected efficiency was initially set as 96.5%. The restricted area of parameter optimization design can be obtained by taking the intersection of the gain requirement, the efficiency requirement, and three restrictions of ZVS (Zero Voltage Switch. The proposed method was verified by simulation and experiments of a 150 W prototype. The results show that the proposed method can achieve ZVS from full-load to no-load conditions and can reach 1.6 times the normalized voltage gain in the frequency variation range of 18 kHz with a peak efficiency of up to 96.3%. Moreover, the expected efficiency is adjustable, which means a converter with a higher efficiency can be designed. The proposed method can also be used for the design of large-power LLC resonant converters to obtain a wide output voltage range and higher efficiency.

  6. The influence of patient positioning uncertainties in proton radiotherapy on proton range and dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Liebl, Jakob, E-mail: jakob.liebl@medaustron.at [EBG MedAustron GmbH, 2700 Wiener Neustadt (Austria); Francis H. Burr Proton Therapy Center, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States); Department of Therapeutic Radiology and Oncology, Medical University of Graz, 8036 Graz (Austria); Paganetti, Harald; Zhu, Mingyao; Winey, Brian A. [Francis H. Burr Proton Therapy Center, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)

    2014-09-15

    Purpose: Proton radiotherapy allows radiation treatment delivery with high dose gradients. The nature of such dose distributions increases the influence of patient positioning uncertainties on their fidelity when compared to photon radiotherapy. The present work quantitatively analyzes the influence of setup uncertainties on proton range and dose distributions. Methods: Thirty-eight clinical passive scattering treatment fields for small lesions in the head were studied. Dose distributions for shifted and rotated patient positions were Monte Carlo-simulated. Proton range uncertainties at the 50%- and 90%-dose falloff position were calculated considering 18 arbitrary combinations of maximal patient position shifts and rotations for two patient positioning methods. Normal tissue complication probabilities (NTCPs), equivalent uniform doses (EUDs), and tumor control probabilities (TCPs) were studied for organs at risk (OARs) and target volumes of eight patients. Results: The authors identified a median 1σ proton range uncertainty at the 50%-dose falloff of 2.8 mm for anatomy-based patient positioning and 1.6 mm for fiducial-based patient positioning as well as 7.2 and 5.8 mm for the 90%-dose falloff position, respectively. These range uncertainties were correlated to heterogeneity indices (HIs) calculated for each treatment field (38% < R{sup 2} < 50%). A NTCP increase of more than 10% (absolute) was observed for less than 2.9% (anatomy-based positioning) and 1.2% (fiducial-based positioning) of the studied OARs and patient shifts. For target volumes TCP decreases by more than 10% (absolute) occurred in less than 2.2% of the considered treatment scenarios for anatomy-based patient positioning and were nonexistent for fiducial-based patient positioning. EUD changes for target volumes were up to 35% (anatomy-based positioning) and 16% (fiducial-based positioning). Conclusions: The influence of patient positioning uncertainties on proton range in therapy of small lesions

  7. Performance of Spanish white Macael marble exposed to narrow- and medium-range temperature cycling

    Directory of Open Access Journals (Sweden)

    Rodríguez Gordillo, J.

    2010-02-01

    Full Text Available White marble specimens from Macael in the Spanish province of Almeria were exposed to narrow- (50/20 ºC and medium- (100/-20 ºC and 75/-20 ºC range thermal stress cycles. The effects were monitored with ultrasound techniques. Ultrasound velocity declined considerably in samples subjected to 100/-20 ºC cycles, more moderately when the range was 75/-20 ºC and insignificantly when it was narrowed to 50/-20 ºC. All variations were recorded in the first five to seven cycles, with values flattening thereafter. The Schmidt hardness and compression test results concurred with the ultrasound findings. Petrographic and scanning electron microscope (SEM imaging revealed some very superficial granular decohesion in the specimens subjected to forty 100/-20 ºC cycles. The concurrent results from compression testing on the one hand and surface hardness and ultrasound measurements on the other confirmed the validity of the latter two nondestructive techniques (NDT for determining the effects of thermal stress cycling on stone mechanical strength.

    Se aplican ciclos de estrés térmico de medio (100/-20 ºC y 75/-20 ºC y bajo (50/-20 ºC rango sobre probetas de mármol blanco de Macael (Almería, España, y se evalúa ciclo a ciclo su incidencia mediante ultrasonidos. Los resultados indican un considerable descenso de velocidad de los ultrasonidos en las muestras sometidas a estrés de 100/-20 ºC, más moderado en el caso de 75/-20 ºC, poco significativo en el caso de 50/-20 ºC. Las variaciones de velocidad tienen lugar durante los primeros ciclos (5-7, permaneciendo los valores constantes en ciclos posteriores. Los resultados proporcionados por medidas de dureza de Schmidt, y de rotura por compresión uniaxial son coincidentes con los proporcionados por los ultrasonidos. Las imágenes de microscopía petrográfica y electrónica (SEM manifiestan una cierta descohesión granular en zonas muy superficiales de las probetas sometidas a 40 ciclos de

  8. Development of new chemical dosimeter for low dose range

    International Nuclear Information System (INIS)

    Mhatre, Sachin G.V.; Adhikari, S.

    2012-01-01

    Accurate measurement of low dose radiation in complex systems is of utmost importance in radiation biology and related areas. Ferrous Benzoic acid Xylenol orange (FBX) system is being widely used for measurement of low dose gamma radiation because of its reproducibility and precision. However, an additional step, i.e., dissolution of benzoic acid in water at higher temperature followed by cooling at room temperature is involved for the preparation of this dosimeter. This makes it inconvenient as a ready to use dosimeter. In the present work, the organic molecule, sorbitol has been used for measurement of low doses of radiation. The advantages of using sorbitol are its ready availability and instantaneous water solubility. Owing to its dissolution at room temperature, possible errors those are involved in calculation of dose due to thermal oxidation of ferrous ions during preparation of the FBX dosimetric solution could be made insignificant in the proposed dosimeter. In the present system, sorbitol acts as radiolytic sensitizer for the oxidation of ferrous ion, and xylenol orange forms a 1:1 complex specifically with ferric ions. Thus, the analytical detection limit of ferric ions is enhanced compared to other systems. Final composition of the dosimetric solution is; 0.5 mol/m 3 xylenol orange, 10 mol/m 3 sorbitol and 0.2 mol/m 3 ferrous ion in 50 mol/m 3 sulfuric acid. Radiolytic sensitization in combination with analytical enhancement of the ferrous based system, allows us to measure radiation dose in the range of 0.05 Gy–12 Gy with ease and high reproducibility.

  9. Evaluation of dose according to the volume and respiratory range during SBRT in lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Deuk Hee [Dept. of Radiation Oncology, Busan Paik Hospital, Inje University, Busan (Korea, Republic of); Park, Eun Tae; Kim, Jung Hoon; Kang, Se Seik [Dept. of Radiological Science, College of Health Sciences, Catholic University of Pusan, Busan (Korea, Republic of)

    2016-09-15

    Stereotactic body radiotherapy is effective technic in radiotherapy for low stage lung cancer. But lung cancer is affected by respiratory so accurately concentrate high dose to the target is very difficult. In this study, evaluated the target volume according to how to take the image. And evaluated the dose by photoluminescence glass dosimeter according to how to contour the volume and respiratory range. As a result, evaluated the 4D CT volume was 10.4 cm{sup 3} which was closest value of real size target. And in dose case is internal target volume dose was 10.82, 16.88, 21.90 Gy when prescribed dose was 10, 15, 20 Gy and it was the highest dose. Respiratory gated radiotherapy dose was more higher than internal target volume. But it made little difference by respiratory range. Therefore, when moving cancer treatment, acquiring image by 4D CT, contouring internal target volume and respiratory gated radiotherapy technic would be the best way.

  10. Evaluation of dose according to the volume and respiratory range during SBRT in lung cancer

    International Nuclear Information System (INIS)

    Lee, Deuk Hee; Park, Eun Tae; Kim, Jung Hoon; Kang, Se Seik

    2016-01-01

    Stereotactic body radiotherapy is effective technic in radiotherapy for low stage lung cancer. But lung cancer is affected by respiratory so accurately concentrate high dose to the target is very difficult. In this study, evaluated the target volume according to how to take the image. And evaluated the dose by photoluminescence glass dosimeter according to how to contour the volume and respiratory range. As a result, evaluated the 4D CT volume was 10.4 cm 3 which was closest value of real size target. And in dose case is internal target volume dose was 10.82, 16.88, 21.90 Gy when prescribed dose was 10, 15, 20 Gy and it was the highest dose. Respiratory gated radiotherapy dose was more higher than internal target volume. But it made little difference by respiratory range. Therefore, when moving cancer treatment, acquiring image by 4D CT, contouring internal target volume and respiratory gated radiotherapy technic would be the best way

  11. Upgrading NASA/DOSE laser ranging system control computers

    Science.gov (United States)

    Ricklefs, Randall L.; Cheek, Jack; Seery, Paul J.; Emenheiser, Kenneth S.; Hanrahan, William P., III; Mcgarry, Jan F.

    1993-01-01

    Laser ranging systems now managed by the NASA Dynamics of the Solid Earth (DOSE) and operated by the Bendix Field Engineering Corporation, the University of Hawaii, and the University of Texas have produced a wealth on interdisciplinary scientific data over the last three decades. Despite upgrades to the most of the ranging station subsystems, the control computers remain a mix of 1970's vintage minicomputers. These encompass a wide range of vendors, operating systems, and languages, making hardware and software support increasingly difficult. Current technology allows replacement of controller computers at a relatively low cost while maintaining excellent processing power and a friendly operating environment. The new controller systems are now being designed using IBM-PC-compatible 80486-based microcomputers, a real-time Unix operating system (LynxOS), and X-windows/Motif IB, and serial interfaces have been chosen. This design supports minimizing short and long term costs by relying on proven standards for both hardware and software components. Currently, the project is in the design and prototyping stage with the first systems targeted for production in mid-1993.

  12. Feasibility of RACT for 3D dose measurement and range verification in a water phantom.

    Science.gov (United States)

    Alsanea, Fahed; Moskvin, Vadim; Stantz, Keith M

    2015-02-01

    The objective of this study is to establish the feasibility of using radiation-induced acoustics to measure the range and Bragg peak dose from a pulsed proton beam. Simulation studies implementing a prototype scanner design based on computed tomographic methods were performed to investigate the sensitivity to proton range and integral dose. Derived from thermodynamic wave equation, the pressure signals generated from the dose deposited from a pulsed proton beam with a 1 cm lateral beam width and a range of 16, 20, and 27 cm in water using Monte Carlo methods were simulated. The resulting dosimetric images were reconstructed implementing a 3D filtered backprojection algorithm and the pressure signals acquired from a 71-transducer array with a cylindrical geometry (30 × 40 cm) rotated over 2π about its central axis. Dependencies on the detector bandwidth and proton beam pulse width were performed, after which, different noise levels were added to the detector signals (using 1 μs pulse width and a 0.5 MHz cutoff frequency/hydrophone) to investigate the statistical and systematic errors in the proton range (at 20 cm) and Bragg peak dose (of 1 cGy). The reconstructed radioacoustic computed tomographic image intensity was shown to be linearly correlated to the dose within the Bragg peak. And, based on noise dependent studies, a detector sensitivity of 38 mPa was necessary to determine the proton range to within 1.0 mm (full-width at half-maximum) (systematic error ionizing radiation-induced acoustics can be used to verify dose distribution and proton range with centi-Gray sensitivity. Realizing this technology into the clinic has the potential to significantly impact beam commissioning, treatment verification during particle beam therapy and image guided techniques.

  13. Monte Carlo simulation applied to radiosurgery narrow beams using MCNP-4C

    International Nuclear Information System (INIS)

    Chaves, A.; Lopes, M.C.; Oliveira, C.

    2001-01-01

    Dose measurements for the narrow photon beams used in radiosurgery are complicated by the lack of electron equilibrium which is a requirement namely for ionometric methods. To overcome this difficulty the use of different dosimetric supports is strongly recommended in order to appreciate the influence of each type of detector. Monte Carlo simulation is another kind of tool to assess the details of the energy deposition phenomena in such narrow photon beams. In this study output factors and depth dose calculated by the Monte Carlo MCNP-4C code are presented and compared with experimental data measured with a diode, a Markus chamber, a 0.125 cc thimble chamber and a Pinpoint chamber. Simulated energy spectra for narrow beams are also presented in order to compare them with the reference 10 cm x 10 cm beam field size and thus discuss the different contributions of the absorbed energy in water, in each case. A detailed analysis on the photon energy spectra showed a slight decrease on the photon mean energy that can be explained by the increased scattering inside the additional collimators. Calculated and measured depth doses curves are in good agreement for most of the collimators. For the two smallest collimators some differences have been pointed and explained according to the characteristics of the detectors (author)

  14. QSOs with narrow emission lines

    International Nuclear Information System (INIS)

    Baldwin, J.A.; Mcmahon, R.; Hazard, C.; Williams, R.E.

    1988-01-01

    Observations of two new high-redshift, narrow-lined QSOs (NLQSOs) are presented and discussed together with observations of similar objects reported in the literature. Gravitational lensing is ruled out as a possible means of amplifying the luminosity for one of these objects. It is found that the NLQSOs have broad bases on their emission lines as well as the prominent narrow cores which define this class. Thus, these are not pole-on QSOs. The FWHM of the emission lines fits onto the smoothly falling tail of the lower end of the line-width distribution for complete QSO samples. The equivalent widths of the combined broad and narrow components of the lines are normal for QSOs of the luminosity range under study. However, the NLQSOs do show ionization differences from broader-lined QSOs; most significant, the semiforbidden C III/C IV intensity ratio is unusually low. The N/C abundance ratio in these objects is found to be normal; the Al/C abundance ratio may be quite high. 38 references

  15. Determination of dose ranges of gamma rays to induce specific changes in three ornamental species

    International Nuclear Information System (INIS)

    Gonzalez J, J.

    2011-11-01

    In order to confirming the possibility of to settle a dose range that takes place directly and not at random, a specific effect independently of the species that is were produced several similar organisms to three ornamental species took place via meristems cultivation: Petunia hybrid, Impatiens walleriana and Sprekelia formosissima, same that were irradiated in an irradiator Gamma cell 220, to different dose: 0, 3.5, 5.0, 7.5, 10, 12.5, 15, 17.5 and 20 Gy. Later on, of the plants treated via in vitro the subsequent generations were obtained until the M 4 . To determine the DL 50 and the possible good doses, the survival parameters, development, morphogenesis and height were evaluated during 8 weeks, interpreting based on them, the possible physiologic and genetic alterations induced by the radiation. The established DL 50 were: 7.5 Gy (Petunia), 19.0 Gy (Impatiens) and 12.0 Gy (Sprekelia). Based on the DL 50 of each species, a range of coincident dose settled down that produces a similar effect in the three species: a range of DL 23 to the DL 50 induces and alteration in the cytokinins production affecting directly in the leaves number, buds and plants taken place by meristem, also a range of DL 32 - DL 50 impacts in the auxins production altering to the radicule system. However, when being superimposed the dose is considered that the investigation should continue. (Author)

  16. Effect of time, dose and fractionation on local control of nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Lee, Anne W.M.; Chan, David K.K.; Poon, Y.F.; Foo, William; Law, Stephen C.K.; O, S.K.; Tung, Stewart Y.; Fowler, Jack F.; Chappell, Rick

    1995-01-01

    To study the effect of radiation factors on local control of nasopharyngeal carcinoma, 1008 patients with similarly staged T1N0-3M0 disease (Ho's classification) were retrospectively analyzed. All patients were treated by megavoltage irradiation alone using the same technique. Four different fractionation schedules had been used sequentially during 1976-1985: with total dose ranging from 45.6 to 60 Gy and fractional dose from 2.5 to 4.2 Gy. The median overall time was 39 days (range = 38-75 days). Both for the whole series and 763 patients with nodal control, total dose was the most important radiation factor. The hazard of local failure decreased by 9% per additional Gy (p < 0.01). Biological equivalents expressed in terms of Biologically Effective Dose or Nominal Standard Dose also showed strong correlation. Fractional dose had no significant impact. The effect of overall treatment time was insignificant for the whole series, but almost reached statistical significance for those with nodal control (p = 0.06). Further study is required for elucidation, as 85% of patients completed treatment within a very narrow range (38-42 days), and the possible hazard is clinically too significant to be ignored

  17. Narrow beam neutron dosimetry.

    Science.gov (United States)

    Ferenci, M Sutton

    2004-01-01

    Organ and effective doses have been estimated for male and female anthropomorphic mathematical models exposed to monoenergetic narrow beams of neutrons with energies from 10(-11) to 1000 MeV. Calculations were performed for anterior-posterior, posterior-anterior, left-lateral and right-lateral irradiation geometries. The beam diameter used in the calculations was 7.62 cm and the phantoms were irradiated at a height of 1 m above the ground. This geometry was chosen to simulate an accidental scenario (a worker walking through the beam) at Flight Path 30 Left (FP30L) of the Weapons Neutron Research (WNR) Facility at Los Alamos National Laboratory. The calculations were carried out using the Monte Carlo transport code MCNPX 2.5c.

  18. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry

    International Nuclear Information System (INIS)

    Chetty, Indrin J.; Charland, Paule M.

    2002-01-01

    We have investigated the dependence of the measured optical density on the incident beam energy, field size and depth for a new type of film, Kodak extended dose range (Kodak EDR). Film measurements have been conducted over a range of field sizes (3x3 cm 2 to 25x25 cm 2 ) and depths (d max to 15 cm), for 6 MV and 15 MV photons within a solid water phantom, and the variation in sensitometric response (net optical density versus dose) has been reported. Kodak EDR film is found to have a linear response with dose, from 0 to 350 cGy, which is much higher than that typically seen for Kodak XV film (0-50 cGy). The variation in sensitometric response for Kodak EDR film as a function of field size and depth is observed to be similar to that of Kodak XV film; the optical density varied in the order of 2-3% for field sizes of 3x3 cm 2 and 10x10 cm 2 at depths of d max , 5 cm and 15 cm in the phantom. Measurements for a 25x25 cm 2 field size showed consistently higher optical densities at depths of d max , 5 cm and 15 cm, relative to a 10x10 cm 2 field size at 5 cm depth, with 4-5% differences noted at a depth of 15 cm. Fractional depth dose and profiles conducted with Kodak EDR film showed good agreement (2%/2 mm) with ion chamber measurements for all field sizes except for the 25x25 cm 2 at depths greater than 15 cm, where differences in the order of 3-5% were observed. In addition, Kodak EDR film measurements were found to be consistent with those of Kodak XV film for all fractional depth doses and profiles. The results of this study indicate that Kodak EDR film may be a useful tool for relative dosimetry at higher dose ranges. (author)

  19. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry.

    Science.gov (United States)

    Chetty, Indrin J; Charland, Paule M

    2002-10-21

    We have investigated the dependence of the measured optical density on the incident beam energy, field size and depth for a new type of film, Kodak extended dose range (Kodak EDR). Film measurements have been conducted over a range of field sizes (3 x 3 cm2 to 25 x 25 cm2) and depths (d(max) to 15 cm), for 6 MV and 15 MV photons within a solid water phantom, and the variation in sensitometric response (net optical density versus dose) has been reported. Kodak EDR film is found to have a linear response with dose, from 0 to 350 cGy, which is much higher than that typically seen for Kodak XV film (0-50 cGy). The variation in sensitometric response for Kodak EDR film as a function of field size and depth is observed to be similar to that of Kodak XV film; the optical density varied in the order of 2-3% for field sizes of 3 x 3 cm2 and 10 x 10 cm2 at depths of d(max), 5 cm and 15 cm in the phantom. Measurements for a 25 x 25 cm2 field size showed consistently higher optical densities at depths of d(max), 5 cm and 15 cm, relative to a 10 x 10 cm2 field size at 5 cm depth, with 4-5% differences noted at a depth of 15 cm. Fractional depth dose and profiles conducted with Kodak EDR film showed good agreement (2%/2 mm) with ion chamber measurements for all field sizes except for the 25 x 25 cm2 at depths greater than 15 cm, where differences in the order of 3-5% were observed. In addition, Kodak EDR film measurements were found to be consistent with those of Kodak XV film for all fractional depth doses and profiles. The results of this study indicate that Kodak EDR film may be a useful tool for relative dosimetry at higher dose ranges.

  20. An analysis of ingestion doses from a range of postulated Magnox reactor releases

    International Nuclear Information System (INIS)

    Nair, S.

    1985-06-01

    An analysis has been carried out of ingestion doses from a range of postulated Magnox reactor releases to atmosphere. Calculations were made of the dose to the adult, ten year old child and one year old child, which showed the one year old child to receive the highest dose. Detailed studies were made of the significance of the ingestion dose to the one year old child in relation to other exposure routes. The ingestion dose was also analysed in terms of the contributing critical organs, foods and nuclides. Approximate calculations were also made of the dependence of the ingestion dose on the time of year when the release occurs. The results of the analysis were used to derive a set of release-specific Emergency Action Guidance Levels (EAGLs) of critical nuclide concentrations in the critical foods, which comply with NRPB's ingestion ERL recommendations. The EAGLs were supplemented with a corresponding set of EAGLs for grass, for use in situations where crop samples were not readily available. (author)

  1. Effect of montelukast on excessive airway narrowing response to methacholine in adult asthmatic patients not on controller therapy

    DEFF Research Database (Denmark)

    Ulrik, Charlotte Suppli; Diamant, Zuzana

    2009-01-01

    -response plateau to Mtc in adult asthmatic patients not on controller therapy, and, hence, protects against excessive airway narrowing. Thirty-one asthmatic patients (13 male patients, 18-50 years old; forced expiratory volume in 1 second [FEV(1)], >70% predicted; PD(20), ...Excessive airway narrowing is an important determinant of fatal asthma. This pathophysiological feature is characterized by the absence of a dose-response plateau to methacholine (Mtc). We investigated if the leukotriene receptor antagonist (LTRA) montelukast (Mont) can induce a dose...... of treatment with Mont neither induced a plateau response nor affected maximum FEV(1) response or PD(20). Our findings, therefore, suggest that monotherapy with a LTRA does not protect against excessive airway narrowing in adult asthmatic patients not on inhaled corticosteroids....

  2. Automated FiO2-SpO2 control system in neonates requiring respiratory support: a comparison of a standard to a narrow SpO2 control range.

    Science.gov (United States)

    Wilinska, Maria; Bachman, Thomas; Swietlinski, Janusz; Kostro, Maria; Twardoch-Drozd, Marta

    2014-05-28

    Managing the oxygen saturation of preterm infants to a target range has been the standard of care for a decade. Changes in target ranges have been shown to significantly impact mortality and morbidity. Selecting and implementing the optimal target range are complicated not only by issues of training, but also the realities of staffing levels and demands. The potential for automatic control is becoming a reality. Results from the evaluation of different systems have been promising and our own experience encouraging. This study was conducted in two tertiary level newborn nurseries, routinely using an automated FiO2-SpO2 control system (Avea-CLiO2, Yorba Linda CA, USA). The aim of this study was to compare the performance of the system as used routinely (set control range of 87-93% SpO2), to a narrower higher range (90-93%). We employed a 12-hour cross-over design with the order of control ranges randomly assigned for each of up to three days. The primary prospectively identified end points were time in the 87-93% SpO2 target range, time at SpO2 extremes and the distribution of the SpO2 exposure. Twenty-one infants completed the study. The infants were born with a median EGA of 27 weeks and studied at a median age of 17 days and weight of 1.08 kg. Their median FiO2 was 0.32; 8 were intubated, and the rest noninvasively supported (7 positive pressure ventilation and 6 CPAP). The control in both arms was excellent, and required less than 2 manual FiO2 adjustments per day. There were no differences in the three primary endpoints. The narrower/higher set control range resulted in tighter control (IQR 3.0 vs. 4.3 p < 0.001), and less time with the SpO2 between 80-86 (6.2% vs. 8.4%, p = 0.006). We found that a shift in the median of the set control range of an automated FiO2-SpO2 control system had a proportional effect on the median and distribution of SpO2 exposure. We found that a dramatic narrowing of the set control range had a disproportionally smaller impact. Our

  3. Ionizing acceleration of color center transformation in the low radiation dose range

    International Nuclear Information System (INIS)

    Mamontov, A.P.; Starodubtsev, V.A.; Chernov, I.P.

    1985-01-01

    The purpose of the study is investigation of annealing and colour centers transformation of known nature in lithium fluoride crystals at the γ-irradiation low doses. The controlled colour centers have been introduced by LiF monocrystal samples irradiation by protons with 6 MeV energy. The γ-radiation dose rate constitutes 25 Grxssup(-1). The variation of absorption spectra caused by proton and γ-irradiation in initial crystals and in the sample being twice exposed has been studied. It is shown that for LiF monocrystals in the γ-radiation low dose range (below 5 kGr) anomalous dependences of concentration of F-aggregate colour centers on the irradiation dose are observed. High efficiency in defects transformation can be caused by the chain of self-sustaining reactions. The observed N-type dependences caused defects decay and competition of the processes of capture of anionic vacancies by F- and F-aggregate centers

  4. Radiation-Induced Short Channel (RISCE) and Narrow Channel (RINCE) Effects in 65 and 130 nm MOSFETs

    CERN Document Server

    Faccio, F; Cornale, D; Paccagnella, A; Gerardin, S

    2015-01-01

    The behavior of transistors in commercial-grade complementary metal-oxide semiconductor technologies in the 65 and 130 nm nodes has been explored up to a total ionizing dose of 1 Grad. The large dose tolerance of the thin gate oxide is confirmed, but defects in the spacer and STI oxides have a strong effect on the performance of the transistors. A radiation-induced short channel effect is traced to charge trapping in the spacers used for drain engineering, while a radiation-induced narrow channel effect is due to defect generation in the lateral isolation oxide (STI). These strongly degrade the electrical characteristics of short and narrow channel transistors at high doses, and their magnitude depends on the applied bias and temperature during irradiation in a complex way.

  5. The influence of coarse-scale environmental features on current and predicted future distributions of narrow-range endemic crayfish populations

    Science.gov (United States)

    Dyer, Joseph J.; Brewer, Shannon K.; Worthington, Thomas A.; Bergey, Elizabeth A.

    2013-01-01

    1.A major limitation to effective management of narrow-range crayfish populations is the paucity of information on the spatial distribution of crayfish species and a general understanding of the interacting environmental variables that drive current and future potential distributional patterns. 2.Maximum Entropy Species Distribution Modeling Software (MaxEnt) was used to predict the current and future potential distributions of four endemic crayfish species in the Ouachita Mountains. Current distributions were modelled using climate, geology, soils, land use, landform and flow variables thought to be important to lotic crayfish. Potential changes in the distribution were forecast by using models trained on current conditions and projecting onto the landscape predicted under climate-change scenarios. 3.The modelled distribution of the four species closely resembled the perceived distribution of each species but also predicted populations in streams and catchments where they had not previously been collected. Soils, elevation and winter precipitation and temperature most strongly related to current distributions and represented 6587% of the predictive power of the models. Model accuracy was high for all models, and model predictions of new populations were verified through additional field sampling. 4.Current models created using two spatial resolutions (1 and 4.5km2) showed that fine-resolution data more accurately represented current distributions. For three of the four species, the 1-km2 resolution models resulted in more conservative predictions. However, the modelled distributional extent of Orconectes leptogonopodus was similar regardless of data resolution. Field validations indicated 1-km2 resolution models were more accurate than 4.5-km2 resolution models. 5.Future projected (4.5-km2 resolution models) model distributions indicated three of the four endemic species would have truncated ranges with low occurrence probabilities under the low-emission scenario

  6. A Monte Carlo multiple source model applied to radiosurgery narrow photon beams

    International Nuclear Information System (INIS)

    Chaves, A.; Lopes, M.C.; Alves, C.C.; Oliveira, C.; Peralta, L.; Rodrigues, P.; Trindade, A.

    2004-01-01

    Monte Carlo (MC) methods are nowadays often used in the field of radiotherapy. Through successive steps, radiation fields are simulated, producing source Phase Space Data (PSD) that enable a dose calculation with good accuracy. Narrow photon beams used in radiosurgery can also be simulated by MC codes. However, the poor efficiency in simulating these narrow photon beams produces PSD whose quality prevents calculating dose with the required accuracy. To overcome this difficulty, a multiple source model was developed that enhances the quality of the reconstructed PSD, reducing also the time and storage capacities. This multiple source model was based on the full MC simulation, performed with the MC code MCNP4C, of the Siemens Mevatron KD2 (6 MV mode) linear accelerator head and additional collimators. The full simulation allowed the characterization of the particles coming from the accelerator head and from the additional collimators that shape the narrow photon beams used in radiosurgery treatments. Eight relevant photon virtual sources were identified from the full characterization analysis. Spatial and energy distributions were stored in histograms for the virtual sources representing the accelerator head components and the additional collimators. The photon directions were calculated for virtual sources representing the accelerator head components whereas, for the virtual sources representing the additional collimators, they were recorded into histograms. All these histograms were included in the MC code, DPM code and using a sampling procedure that reconstructed the PSDs, dose distributions were calculated in a water phantom divided in 20000 voxels of 1x1x5 mm 3 . The model accurately calculates dose distributions in the water phantom for all the additional collimators; for depth dose curves, associated errors at 2σ were lower than 2.5% until a depth of 202.5 mm for all the additional collimators and for profiles at various depths, deviations between measured

  7. DNA excision repair as a component of adaptation to low doses of ionizing radiation Escherichia coli

    International Nuclear Information System (INIS)

    Huang, H.; Claycamp, H.G.

    1993-01-01

    In this study the authors examined whether or not DNA excision repair is a component of adaptation induced by very low-dose ionizing radiation in Escherichia coli, a well-characterized prokaryote, and investigated the relationship between enhanced excision repair and the SOS response. Their data suggest that there seems to be narrow 'windows' of dose-effect for the induction of SOS-independent DNA excision repair. Being similar to mammalian cell studies, the dose range for this effect was about 200-fold less than D 37 for radiation survival. (author)

  8. Vibration-tolerant narrow-linewidth semiconductor disk laser using novel frequency-stabilisation schemes

    Science.gov (United States)

    Hunter, Craig R.; Jones, Brynmor E.; Schlosser, Peter; Sørensen, Simon Toft; Strain, Michael J.; McKnight, Loyd J.

    2018-02-01

    This paper will present developments in narrow-linewidth semiconductor-disk-laser systems using novel frequencystabilisation schemes for reduced sensitivity to mechanical vibrations, a critical requirement for mobile applications. Narrow-linewidth single-frequency lasers are required for a range of applications including metrology and highresolution spectroscopy. Stabilisation of the laser was achieved using a monolithic fibre-optic ring resonator with free spectral range of 181 MHz and finesse of 52 to act as passive reference cavity for the laser. Such a cavity can operate over a broad wavelength range and is immune to a wide band of vibrational frequency noise due to its monolithic implementation. The frequency noise of the locked system has been measured and compared to typical Fabry-Perotlocked lasers using vibration equipment to simulate harsh environments, and analysed here. Locked linewidths of portable, narrow-linewidth laser system for harsh environments that can be flexibly designed for a range of applications.

  9. An analysis of ingestion doses from a range of postulated Magnox reactor releases

    International Nuclear Information System (INIS)

    Nair, S.

    1986-01-01

    An analysis was carried out of ingestion doses from a range of postulated Magnox reactor releases to the atmosphere. Doses to the adult, ten year old child and one year old child were calculated, which showed the one year old child to receive the highest dose. Detailed studies were made of the significance of the ingestion dose to the one year old child in relation to other exposure routes. The ingestion dose was analysed for its contributing critical organs, foods and nuclides. Approximate calculations were also made of the dependence of the ingestion dose on the time of year when the release occurs. The ingestion pathway was found to dominate if the release occurs towards the end of the growing season but to be less significant relative to other exposure pathways at all other times. The calculations enabled a set of release-specific emergency action guidance levels of critical nuclide concentrations in the critical foods to be produced, which comply with NRPB's ingestion Emergency Reference Level guidelines. (author)

  10. Two factors influencing dose reconstruction in low dose range: the variability of BKG intensity on one individual and water content

    International Nuclear Information System (INIS)

    Zhang, Tengda; Zhang, Wenyi; Zhao, Zhixin; Zhang, Haiying; Ruan, Shuzhou; Jiao, Ling

    2016-01-01

    A fast and accurate retrospective dosimetry method for the triage is very important in radiation accidents. Electron paramagnetic resonance (EPR) fingernail dosimetry is a promising way to estimate radiation dose. This article presents two factors influencing dose reconstruction in low dose range: the variability of background signal (BKG) intensity on one individual and water content. Comparing the EPR spectrum of dried and humidified fingernail samples, it is necessary to add a procedure of dehydration before EPR measurements, so as to eliminate the deviation caused by water content. Besides, the BKGs of different fingers' nails are not the same as researchers thought previously, and the difference between maximum and minimum BKG intensities of one individual can reach 55.89 %. Meanwhile, the variability of the BKG intensity among individuals is large enough to impact precise dose reconstruction. Water within fingernails and instability of BKG are two reasons that cause the inaccuracy of radiation dose reconstruction in low-dosage level. (authors)

  11. Acquisition and visualization techniques for narrow spectral color imaging.

    Science.gov (United States)

    Neumann, László; García, Rafael; Basa, János; Hegedüs, Ramón

    2013-06-01

    This paper introduces a new approach in narrow-band imaging (NBI). Existing NBI techniques generate images by selecting discrete bands over the full visible spectrum or an even wider spectral range. In contrast, here we perform the sampling with filters covering a tight spectral window. This image acquisition method, named narrow spectral imaging, can be particularly useful when optical information is only available within a narrow spectral window, such as in the case of deep-water transmittance, which constitutes the principal motivation of this work. In this study we demonstrate the potential of the proposed photographic technique on nonunderwater scenes recorded under controlled conditions. To this end three multilayer narrow bandpass filters were employed, which transmit at 440, 456, and 470 nm bluish wavelengths, respectively. Since the differences among the images captured in such a narrow spectral window can be extremely small, both image acquisition and visualization require a novel approach. First, high-bit-depth images were acquired with multilayer narrow-band filters either placed in front of the illumination or mounted on the camera lens. Second, a color-mapping method is proposed, using which the input data can be transformed onto the entire display color gamut with a continuous and perceptually nearly uniform mapping, while ensuring optimally high information content for human perception.

  12. Dose reader CD-02

    International Nuclear Information System (INIS)

    Jakowiuk, A.; Kaluska, I.; Machaj, B.

    2005-01-01

    Dose Reader CD-02 is designed for measurement of dose from a long narrow band of dosimetric foil used for check up and control of electron beam dose during sterilization of materials and products on conveyor belt. Irradiated foil after processing (heating) is inserted into foil driving (moving) system and when the foil is moved across focused light beam the absorbed dose is measured and displayed at the same time at computer monitor (in form of a diagram). The absorbed dose is measured on the principle of light attenuation at selected light wavelength (foil absorbance is measured). (author)

  13. Three-Body Recombination near a Narrow Feshbach Resonance in Li 6

    Science.gov (United States)

    Li, Jiaming; Liu, Ji; Luo, Le; Gao, Bo

    2018-05-01

    We experimentally measure and theoretically analyze the three-atom recombination rate, L3, around a narrow s -wave magnetic Feshbach resonance of Li 6 - Li 6 at 543.3 G. By examining both the magnetic field dependence and, especially, the temperature dependence of L3 over a wide range of temperatures from a few μ K to above 200 μ K , we show that three-atom recombination through a narrow resonance follows a universal behavior determined by the long-range van der Waals potential and can be described by a set of rate equations in which three-body recombination proceeds via successive pairwise interactions. We expect the underlying physical picture to be applicable not only to narrow s wave resonances, but also to resonances in nonzero partial waves, and not only at ultracold temperatures, but also at much higher temperatures.

  14. Improved spatial resolution and lower-dose pediatric CT imaging: a feasibility study to evaluate narrowing the X-ray photon energy spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Benz, Mark G. [Safer Pediatric Imaging and Engineering Horizons International, Lincoln, VT (United States); Benz, Matthew W. [Southboro Medical Group, Southboro, MA (United States); Birnbaum, Steven B. [Dartmouth Hitchcock Clinic Manchester, Department of Radiology, Manchester, NH (United States); Chason, Eric; Sheldon, Brian W. [Brown University, Division of Engineering, Materials Science and Engineering Program, Providence, RI (United States); McGuire, Dale [R and D Manager, C and G Technologies Inc., Jeffersonville, IN (United States)

    2014-08-15

    This feasibility study has shown that improved spatial resolution and reduced radiation dose can be achieved in pediatric CT by narrowing the X-ray photon energy spectrum. This is done by placing a hafnium filter between the X-ray generator and a pediatric abdominal phantom. A CT system manufactured in 1999 that was in the process of being remanufactured was used as the platform for this study. This system had the advantage of easy access to the X-ray generator for modifications to change the X-ray photon energy spectrum; it also had the disadvantage of not employing the latest post-imaging noise reduction iterative reconstruction technology. Because we observed improvements after changing the X-ray photon energy spectrum, we recommend a future study combining this change with an optimized iterative reconstruction noise reduction technique. (orig.)

  15. Determination of Seed Soundness in Conifers Cryptomeria japonica and Chamaecyparis obtusa Using Narrow-Multiband Spectral Imaging in the Short-Wavelength Infrared Range

    Science.gov (United States)

    Matsuda, Osamu; Hara, Masashi; Tobita, Hiroyuki; Yazaki, Kenichi; Nakagawa, Toshinori; Shimizu, Kuniyoshi; Uemura, Akira; Utsugi, Hajime

    2015-01-01

    Regeneration of planted forests of Cryptomeria japonica (sugi) and Chamaecyparis obtuse (hinoki) is the pressing importance to the forest administration in Japan. Low seed germination rate of these species, however, has hampered low-cost production of their seedlings for reforestation. The primary cause of the low germinability has been attributed to highly frequent formation of anatomically unsound seeds, which are indistinguishable from sound germinable seeds by visible observation and other common criteria such as size and weight. To establish a method for sound seed selection in these species, hyperspectral imaging technique was used to identify a wavelength range where reflectance spectra differ clearly between sound and unsound seeds. In sound seeds of both species, reflectance in a narrow waveband centered at 1,730 nm, corresponding to a lipid absorption band in the short-wavelength infrared (SWIR) range, was greatly depressed relative to that in adjacent wavebands on either side. Such depression was absent or less prominent in unsound seeds. Based on these observations, a reflectance index SQI, abbreviated for seed quality index, was formulated using reflectance at three narrow SWIR wavebands so that it represents the extent of the depression. SQI calculated from seed area-averaged reflectance spectra and spatial distribution patterns of pixelwise SQI within each seed area were both proven as reliable criteria for sound seed selection. Enrichment of sound seeds was accompanied by an increase in germination rate of the seed lot. Thus, the methods described are readily applicable toward low-cost seedling production in combination with single seed sowing technology. PMID:26083366

  16. Broad Anatomical Variation within a Narrow Wood Density Range--A Study of Twig Wood across 69 Australian Angiosperms.

    Science.gov (United States)

    Ziemińska, Kasia; Westoby, Mark; Wright, Ian J

    2015-01-01

    Just as people with the same weight can have different body builds, woods with the same wood density can have different anatomies. Here, our aim was to assess the magnitude of anatomical variation within a restricted range of wood density and explore its potential ecological implications. Twig wood of 69 angiosperm tree and shrub species was analyzed. Species were selected so that wood density varied within a relatively narrow range (0.38-0.62 g cm-3). Anatomical traits quantified included wood tissue fractions (fibres, axial parenchyma, ray parenchyma, vessels, and conduits with maximum lumen diameter below 15 μm), vessel properties, and pith area. To search for potential ecological correlates of anatomical variation the species were sampled across rainfall and temperature contrasts, and several other ecologically-relevant traits were measured (plant height, leaf area to sapwood area ratio, and modulus of elasticity). Despite the limited range in wood density, substantial anatomical variation was observed. Total parenchyma fraction varied from 0.12 to 0.66 and fibre fraction from 0.20 to 0.74, and these two traits were strongly inversely correlated (r = -0.86, P area to sapwood area ratio, and modulus of elasticity (0.24 ≤|r|≤ 0.41, P area to sapwood area ratio (0.47 ≤|r|≤ 0.65, all P area spectrum. The fibre-parenchyma spectrum does not yet have any clear or convincing ecological interpretation.

  17. Development of dose monitoring system applicable to various radiations with wide energy ranges

    International Nuclear Information System (INIS)

    Sato, Tatsuhiko; Satoh, Daiki; Endo, Akira

    2006-01-01

    A new radiation dose monitor, designated as DARWIN (Dose monitoring system Applicable to various Radiations with WIde energy raNges), has been developed for real-time monitoring of doses in workspaces and surrounding environments of high energy accelerator facilities. DARWIN is composed of a phoswitch-type scintillation detector, which consists of liquid organic scintillator BC501A coupled with ZnS(Ag) scintillation sheets doped with 6 Li, and a data acquisition system based on a Digital-Storage-Oscilloscope. DARWIN has the following features: (1) capable of monitoring doses from neutrons, photons and muons with energies from thermal energy to 1 GeV, 150 keV to 100 MeV, and 1 MeV to 100 GeV, respectively, (2) highly sensitive with precision, and (3) easy to operate with a simple graphical user-interface. The performance of DARWIN was examined experimentally in several radiation fields. The results of the experiments indicated the accuracy and rapid response of DARWIN for measuring dose rates from neutrons, photons and muons with wide energies. With these properties, we conclude that DARWIN will be able to play a very important role for improving radiation safety in high energy accelerator facilities. (author)

  18. TRADOS - an air trajectory dose model for long range transport of radioactive release to the atmosphere

    International Nuclear Information System (INIS)

    Rossi, J.; Valkama, I.

    1985-01-01

    A model for estimating radiation doses resulting from long range atmospheric transport of released radionuclides in accidents is precented. The model (TRADOS) is able to treat changing diffusion conditions. For example the plume can be exposed to temporary rain, changes in turbulence and mixing depth. This can result in considerable changes in individual doses. The method is applied to an example trajectory and the doses caused by a serious reactor accident are calculated

  19. SU-E-T-324: The Influence of Patient Positioning Uncertainties in Proton Radiotherapy On Proton Range and Dose Distributions

    Energy Technology Data Exchange (ETDEWEB)

    Liebl, J [EBG MedAustron GmbH, Wiener Neustadt (Austria); Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States); Medical University of Graz, Graz (Austria); Paganetti, H; Winey, B [Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts (United States)

    2014-06-01

    Purpose: Proton radiotherapy allows radiation treatment delivery with high dose gradients. The nature of such dose distributions increases the influence of patient positioning uncertainties on their fidelity when compared to photon radiotherapy. The present work quantitatively analyzes the influence of setup uncertainties on proton range and dose distributions. Methods: 38 clinical passive scattering treatment fields for small lesions in the head were studied. Dose distributions for shifted and rotated patient positions were Monte Carlo-simulated. Proton range uncertainties at the 50% and 90%-dose falloff position were calculated considering 18 arbitrary combinations of maximal patient position shifts and rotations for two patient positioning methods. Normal tissue complication probabilities (NTCPs), equivalent uniform doses (EUDs) and tumor control probabilities (TCPs) were studied for organs at risk (OARs) and target volumes of eight patients. Results: We identified a median 1σ proton range uncertainty at the 50%-dose falloff of 2.8 mm for anatomy-based patient positioning and 1.6 mm for fiducial-based patient positioning as well as 7.2 mm and 5.8 mm for the 90%-dose falloff position respectively. These range uncertainties were correlated to heterogeneity indices (HIs) calculated for each treatment field (38% < R{sup 2} < 50%). A NTCP increase of more than 10% (absolute) was observed for less than 2.9% (anatomy-based positioning) and 1.2% (fiducial-based positioning) of the studied OARs and patient shifts. TCP decreases larger than 10% (absolute) were seen for less than 2.2% of the target volumes or non-existent. EUD changes were up to 178% for OARs and 35% for target volumes. Conclusion: The influence of patient positioning uncertainties on proton range in therapy of small lesions in the human brain and target and OAR dosimetry were studied. Observed range uncertainties were correlated with HIs. The clinical practice of using multiple compensator

  20. Ultra-narrow bandpass filters for long range optical telecommunications at 1064nm and 1550nm, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ultra-narrow bandpass filters with high off-band rejection are needed to maximize signal to noise for free space communications. Omega Optical is developing NIR...

  1. Dose comparison according to Smooth Thickness application of Range compensator during proton therapy for brain tumor patient

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tase Woan; Kim, Dae Woong; Kim, Jae Weon; Jeong, Kyeong Sik [Proton Therapy Center, National Cancer Center, Goyang (Korea, Republic of)

    2016-12-15

    Range Compensator used for proton therapy compensates the proton beam dose which delivers to the normal tissues according to the Target's Distal Margin dose. We are going to check the improvement of dose on the target part by comparing the dose of PTV and OAR according to applying in different method of Smooth Thickness of Range Compensator which is used in brain tumor therapy. For 10 brain tumor patients taking proton therapy in National Cancer Center, Apply Smooth Thickness applied in Range Compensator in order from one to five by using Compensator Editor of Eclipse Proton Planning System(Version 10.0, Varian, USA). The therapy plan algorithm used Proton Convolution Superposition(version 8.1.20 or 10.0.28), and we compared Dmax, Dmin, Homogeneity Index, Conformity Index and OAR dose around tumor by applying Smooth Thickness in phase. When Smooth Thickness was applied from one to five, the Dmax of PTV was decreased max 4.3%, minimum at 0.8 and average of 1.81%. Dmin increased max 1.8%, min 1.8% and average. Difference between max dose and minimum dose decreased at max 5.9% min 1.4% and average 2.6%. Homogeneity Index decreased average of 0.018 and Conformity Index didn't had a meaningful change. OAR dose decreased in Brain Stem at max 1.6%, min 0.1% and average 0.6% and in Optic Chiasm max 1.3%, min 0.3%, and average 0.5%. However, patient C and patient E had an increase each 0.3% and 0.6%. Additionally, in Rt. Optic Nerve, there was a decrease at max 1.5%, min 0.3%, and average 0.8%, however, patient B had 0.1% increase. In Lt. Optic Nerve, there was a decrease at max 1.8%, min 0.3%, and average 0.7%, however, patient H had 0.4 increase. As Smooth Thickness of Range Compensator which is used as the proton treatment for brain tumor patients is applied in stages, the resolution of Compensator increased and as a result the most optimized amount of proton beam dose can be delivered. This is considered to be able to irradiate the equal amount at PTV and

  2. Novel structural flexibility identification in narrow frequency bands

    International Nuclear Information System (INIS)

    Zhang, J; Moon, F L

    2012-01-01

    A ‘Sub-PolyMAX’ method is proposed in this paper not only for estimating modal parameters, but also for identifying structural flexibility by processing the impact test data in narrow frequency bands. The traditional PolyMAX method obtains denominator polynomial coefficients by minimizing the least square (LS) errors of frequency response function (FRF) estimates over the whole frequency range, but FRF peaks in different structural modes may have different levels of magnitude, which leads to the modal parameters identified for the modes with small FRF peaks being inaccurate. In contrast, the proposed Sub-PolyMAX method implements the LS solver in each subspace of the whole frequency range separately; thus the results identified from a narrow frequency band are not affected by FRF data in other frequency bands. In performing structural identification in narrow frequency bands, not in the whole frequency space, the proposed method has the following merits: (1) it produces accurate modal parameters, even for the modes with very small FRF peaks; (2) it significantly reduces computation cost by reducing the number of frequency lines and the model order in each LS implementation; (3) it accurately identifies structural flexibility from impact test data, from which structural deflection under any static load can be predicted. Numerical and laboratory examples are investigated to verify the effectiveness of the proposed method. (paper)

  3. Radiation doses due to long-range transport of airborne radionuclides

    International Nuclear Information System (INIS)

    Nordlund, G.; Valkama, I.; Rossi, J.; Savolainen, I.

    1985-12-01

    Within the framework of this study a model for estimating the long range transport of radioactive material and for calculating the resultant doses is developed. In the model initially the dispersion paths, i.e. trajectories, of the radioactive matter are calculated from the assumed source areas as well as the dispersion conditions along the trajectories. The trajectories are calculated at three-hour intervals in a two-dimensional grid using numerically analysed winds at a constant pressure level of 850 mb. The dispersion condition parameters applied are: the stability of the atmospheric boundary layer, the so-called mixing height, occurrence of precipitation and the character of the terrain. For each trajectory a type-index value is computed, describing the severity of the possible effects of radioactivity transported by the particular trajectory. The dispersion model uses the information on dispersion conditions provided by the trajectory model to compute the remaining radioactivity in the cloud, the deposition, as well as the doses due to different dose pathways. The pathways used are the external radiation from the cloud and from the activity deposited on the ground, inhalation of radioactive material and ingestion of contaminated food products (milk, meat, green vegetables, grain and roots). In addition to the effects of individual transport incidents, the cumulative probability distributions of the effects of accidental releases of radioactive matter can also be calculated using trajectory statistics and the trajectory type index

  4. Radiolysis of aqueous solutions of ammonium bicarbonate over a large dose range

    International Nuclear Information System (INIS)

    Draganic, Z.D.; Negron-Mendoza, A.; Vujosevic, S.I.; Navarro-Gonzales, R.; Albarran-Sanchez, M.G.

    1991-01-01

    Oxygen-free aqueous solutions of 0.05 mol dm -3 ammonium and sodium bicarbonate were studied after receiving various doses of 60 Co gammas (0.01-400 kGy) or 0.5-20 Gy pulses of 10 Mev electrons. Formate and oxalate were found to be the main radiolytic products, in addition to trace amounts of formaldehyde and an unidentified polymer. A large initial yield of formate in the γ-radiolysis, G(HCOO - ) = 2.2, is due to the reaction COO - + HCO 3 - ↔ HCOO - +CO 3 - . The efficiency of organic synthesis within the large dose range studied is low and is explained by efficient pathways leading to the reformation of bicarbonate, where the reaction COO - + CO 3 - is particularly significant. (author)

  5. Cervical spinal canal narrowing and cervical neurologi-cal injuries

    Directory of Open Access Journals (Sweden)

    ZHANG Ling

    2012-04-01

    Full Text Available 【Abstract】Cervical spinal canal narrowing can lead to injury of the spinal cord and neurological symptoms in-cluding neck pain, headache, weakness and parasthesisas. According to previous and recent clinical researches, we investigated the geometric parameters of normal cervical spinal canal including the sagittal and transverse diameters as well as Torg ratio. The mean sagittal diameter of cervical spinal canal at C 1 to C 7 ranges from 15.33 mm to 20.46 mm, the mean transverse diameter at the same levels ranges from 24.45 mm to 27.00 mm and the mean value of Torg ratio is 0.96. With respect to narrow cervical spinal canal, the following charaterstics are found: firstly, extension of the cervical spine results in statistically significant stenosis as compared with the flexed or neutral positions; secondly, females sustain cervical spinal canal narrowing more easily than males; finally, the consistent narrowest cervical canal level is at C 4 for all ethnicity, but there is a slight variation in the sagittal diameter of cervical spinal stenosis (≤14 mm in Whites, ≤ 12 mm in Japanese, ≤13.7 mm in Chinese. Narrow sagittal cervical canal diameter brings about an increased risk of neurological injuries in traumatic, degenerative and inflam-matory conditions and is related with extension of cervical spine, gender, as well as ethnicity. It is hoped that this re-view will be helpful in diagnosing spinal cord and neuro-logical injuries with the geometric parameters of cervical spine in the future. Key words: Spinal cord injuries; Spinal stenosis; Trauma, nervous system

  6. Fracture strength and probability of survival of narrow and extra-narrow dental implants after fatigue testing: In vitro and in silico analysis.

    Science.gov (United States)

    Bordin, Dimorvan; Bergamo, Edmara T P; Fardin, Vinicius P; Coelho, Paulo G; Bonfante, Estevam A

    2017-07-01

    To assess the probability of survival (reliability) and failure modes of narrow implants with different diameters. For fatigue testing, 42 implants with the same macrogeometry and internal conical connection were divided, according to diameter, as follows: narrow (Ø3.3×10mm) and extra-narrow (Ø2.9×10mm) (21 per group). Identical abutments were torqued to the implants and standardized maxillary incisor crowns were cemented and subjected to step-stress accelerated life testing (SSALT) in water. The use-level probability Weibull curves, and reliability for a mission of 50,000 and 100,000 cycles at 50N, 100, 150 and 180N were calculated. For the finite element analysis (FEA), two virtual models, simulating the samples tested in fatigue, were constructed. Loading at 50N and 100N were applied 30° off-axis at the crown. The von-Mises stress was calculated for implant and abutment. The beta (β) values were: 0.67 for narrow and 1.32 for extra-narrow implants, indicating that failure rates did not increase with fatigue in the former, but more likely were associated with damage accumulation and wear-out failures in the latter. Both groups showed high reliability (up to 97.5%) at 50 and 100N. A decreased reliability was observed for both groups at 150 and 180N (ranging from 0 to 82.3%), but no significant difference was observed between groups. Failure predominantly involved abutment fracture for both groups. FEA at 50N-load, Ø3.3mm showed higher von-Mises stress for abutment (7.75%) and implant (2%) when compared to the Ø2.9mm. There was no significant difference between narrow and extra-narrow implants regarding probability of survival. The failure mode was similar for both groups, restricted to abutment fracture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Infection of non-host model plant species with the narrow-host-range Cacao swollen shoot virus.

    Science.gov (United States)

    Friscina, Arianna; Chiappetta, Laura; Jacquemond, Mireille; Tepfer, Mark

    2017-02-01

    Cacao swollen shoot virus (CSSV) is a major pathogen of cacao (Theobroma cacao) in Africa, and long-standing efforts to limit its spread by the culling of infected trees have had very limited success. CSSV is a particularly difficult virus to study, as it has a very narrow host range, limited to several tropical tree species. Furthermore, the virus is not mechanically transmissible, and its insect vector can only be used with difficulty. Thus, the only efficient means to infect cacao plants that have been experimentally described so far are by particle bombardment or the agroinoculation of cacao plants with an infectious clone. We have genetically transformed three non-host species with an infectious form of the CSSV genome: two experimental hosts widely used in plant virology (Nicotiana tabacum and N. benthamiana) and the model species Arabidopsis thaliana. In transformed plants of all three species, the CSSV genome was able to replicate, and, in tobacco, CSSV particles could be observed by immunosorbent electron microscopy, demonstrating that the complete virus cycle could be completed in a non-host plant. These results will greatly facilitate the preliminary testing of CSSV control strategies using plants that are easy to raise and to transform genetically. © 2016 BSPP AND JOHN WILEY & SONS LTD.

  8. Analytical approximations for wide and narrow resonances

    International Nuclear Information System (INIS)

    Suster, Luis Carlos; Martinez, Aquilino Senra; Silva, Fernando Carvalho da

    2005-01-01

    This paper aims at developing analytical expressions for the adjoint neutron spectrum in the resonance energy region, taking into account both narrow and wide resonance approximations, in order to reduce the numerical computations involved. These analytical expressions, besides reducing computing time, are very simple from a mathematical point of view. The results obtained with this analytical formulation were compared to a reference solution obtained with a numerical method previously developed to solve the neutron balance adjoint equations. Narrow and wide resonances of U 238 were treated and the analytical procedure gave satisfactory results as compared with the reference solution, for the resonance energy range. The adjoint neutron spectrum is useful to determine the neutron resonance absorption, so that multigroup adjoint cross sections used by the adjoint diffusion equation can be obtained. (author)

  9. Analytical approximations for wide and narrow resonances

    Energy Technology Data Exchange (ETDEWEB)

    Suster, Luis Carlos; Martinez, Aquilino Senra; Silva, Fernando Carvalho da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: aquilino@lmp.ufrj.br

    2005-07-01

    This paper aims at developing analytical expressions for the adjoint neutron spectrum in the resonance energy region, taking into account both narrow and wide resonance approximations, in order to reduce the numerical computations involved. These analytical expressions, besides reducing computing time, are very simple from a mathematical point of view. The results obtained with this analytical formulation were compared to a reference solution obtained with a numerical method previously developed to solve the neutron balance adjoint equations. Narrow and wide resonances of U{sup 238} were treated and the analytical procedure gave satisfactory results as compared with the reference solution, for the resonance energy range. The adjoint neutron spectrum is useful to determine the neutron resonance absorption, so that multigroup adjoint cross sections used by the adjoint diffusion equation can be obtained. (author)

  10. Artificial neural network applied to ONB in vertical narrow annulus experiment

    International Nuclear Information System (INIS)

    Yun Guo; Guanghui Su; Dounan Jia; Jiaqiang Wang

    2005-01-01

    Full text of publication follows: It is very important to study the onset of nucleate boiling (ONB) in narrow channel. Engineering applications of the narrow channel are used more and more widely. The narrow channel is used in microelectronics. Narrow annular channel is also adopted to design the new type of heat exchanger. The ONB is usually regarded as the point of demarcation between the single-phase flow and two phase flow. So it is significant to study the onset of nucleate boiling in the judgment of the flow pattern and engineering design. Although the researches showed that the ONB in narrow space channel were different from that in common pipe, most of them did not study the bilateral heated effect on the ONB. The ONB was investigated for water flowing in the annular channel which gap is 1.2 mm at the pressure range from 0.10 to 5.0 MPa. The effect of some parameters on the ONB, such as the mass flux, pressure, inlet subcooled temperature, bilateral heating was analyzed. But the experiment has not been carried in great wide range of the pressure and flow flux. So the artificial neural networks were used to predict the ONB at wide range parameter. Recently artificial neural networks (ANNs) have been used widely in the field of reactor thermal-hydraulics because they can solve very complex multivariable and high non-linearity problems. The researchers can pay attention to the output results and be unaware of the inside characters of the networks. Most of them are used to predict the critical heat flux and some other accident problems. In fact some small-scale artificial neural networks can be used in thermal-hydraulic experiments easily. Based on the ONB experimental data, an artificial neural network (BP) is built to specify the ONB. According to a lot of experiments data another middle scale ANN is built to predict the ONB of narrow gap annular channels. The results are compared with other correlations. It was concluded that the power density of ONB in the

  11. Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance

    International Nuclear Information System (INIS)

    Olch, Arthur J.

    2002-01-01

    Film-based quality assurance (QA) is an important element of any intensity modulated radiation therapy (IMRT) program. XV2 film is often used for IMRT QA, however, it has saturation and energy response limitations which hinder accurate film dosimetry. A new commercially released ready-pack film has been introduced that has an extended dose range (EDR2), reportedly allowing measured doses above 600 cGy without saturation. Also, this film may have less energy dependence due to its composition. The purpose of this paper is to study and compare the two types of film with respect to absolute dose accuracy for IMRT plans, percent depth dose accuracy for square fields between 2 and 20 cm, ability to measure composite plan isodoses and single beam fluence maps for IMRT cases, and sensitivity to processor variations over time. In 19 IMRT patient QA tests, the EDR2 film was able to achieve an absolute dose accuracy of better than 2% vs over 4% for XV2 film. The EDR2 film was able to reproduce ionization chamber and diode-measured percent depth doses to 20 cm depth generally to within 1% over the range of field sizes tested compared to about 10% for the XV2 film. When compared to calculations, EDR2 film agreed better than XV2 film for both composite plan isodoses and single beam fluence intensity maps. The EDR2 film was somewhat more resistant to processor changes over time than the XV2 film, with a standard deviation of dose reproducibility of less than 2% compared to 6%, respectively

  12. Nasal base narrowing: the combined alar base excision technique.

    Science.gov (United States)

    Foda, Hossam M T

    2007-01-01

    To evaluate the role of the combined alar base excision technique in narrowing the nasal base and correcting excessive alar flare. The study included 60 cases presenting with a wide nasal base and excessive alar flaring. The surgical procedure combined an external alar wedge resection with an internal vestibular floor excision. All cases were followed up for a mean of 32 (range, 12-144) months. Nasal tip modification and correction of any preexisting caudal septal deformities were always completed before the nasal base narrowing. The mean width of the external alar wedge excised was 7.2 (range, 4-11) mm, whereas the mean width of the sill excision was 3.1 (range, 2-7) mm. Completing the internal excision first resulted in a more conservative external resection, thus avoiding any blunting of the alar-facial crease. No cases of postoperative bleeding, infection, or keloid formation were encountered, and the external alar wedge excision healed with an inconspicuous scar that was well hidden in the depth of the alar-facial crease. Finally, the risk of notching of the alar rim, which can occur at the junction of the external and internal excisions, was significantly reduced by adopting a 2-layered closure of the vestibular floor (P = .01). The combined alar base excision resulted in effective narrowing of the nasal base with elimination of excessive alar flare. Commonly feared complications, such as blunting of the alar-facial crease or notching of the alar rim, were avoided by using simple modifications in the technique of excision and closure.

  13. Experimental Study on Critical Power in a Hemispherical Narrow Gap

    International Nuclear Information System (INIS)

    Park, Rae-Joon; Ha, Kwang-Soon; Kim, Sang-Baik; Kim, Hee-Dong; Jeong, Ji-Hwan

    2002-01-01

    An experimental study of critical heat flux in gap (CHFG) has been performed to investigate the inherent cooling mechanism in a hemispherical narrow gap. The objectives of the CHFG test are to measure critical power from a critical heat removal rate through the hemispherical narrow gap using distilled water with experimental parameters of system pressure and gap width. The CHFG test results have shown that a countercurrent flow limitation (CCFL) brings about local dryout at the small edge region of the upper part and finally global dryout in a hemispherical narrow gap. Increases in the gap width and pressure lead to an increase in critical power. The measured values of critical power are lower than the predictions made by other empirical CHF correlations applicable to flat plate, annuli, and small spherical gaps. The measured data on critical power in the hemispherical narrow gaps have been correlated using nondimensional parameters with a range of approximately ±20%. The developed correlation has been expanded to apply the spherical geometry using the Siemens/KWU correlation

  14. Phase I (or phase II) dose-ranging clinical trials: proposal of a two-stage Bayesian design.

    Science.gov (United States)

    Zohar, Sarah; Chevret, Sylvie

    2003-02-01

    We propose a new design for phase I (or phase II) dose-ranging clinical trials aiming at determining a dose of an experimental treatment to satisfy safety (respectively efficacy) requirements, at treating a sufficiently large number of patients to estimate the toxicity (respectively failure) probability of the dose level with a given reliability, and at stopping the trial early if it is likely that no dose is safe (respectively efficacious). A two-stage design was derived from the Continual Reassessment Method (CRM), with implementation of Bayesian criteria to generate stopping rules. A simulation study was conducted to compare the operating characteristics of the proposed two-stage design to those reached by the traditional CRM. Finally, two applications to real data sets are provided.

  15. X-γ dose rate continuous monitor with wide range based on single-chip microcomputer

    International Nuclear Information System (INIS)

    Wu Debo; Ling Qiu; Guo Lanying; Yang Binhua

    2007-01-01

    This paper describes a concept about circuit designing of X-γ dose rate continuous monitor with wide range based on single-chip microcomputer, and also presents the design procedure of hardware and software, and gives several methods for solving the design procedure of hardware and software with emphasis. (authors)

  16. Definition of Quality Criteria of the Technological Process of Narrow Web UV-Printing

    Directory of Open Access Journals (Sweden)

    Volodymyr Shybanov

    2013-11-01

    Full Text Available The application of Narrow Web UV-flexographic printing has several advantages compared with offset printing. In particular, they are the lack of the operation of water-ink balance setting in the technological process, the ability to print on a wide range of materials and so on. Though the imprint quality is clearly based on standards in offset printing, there are no clearly indicated requirements for Narrow Web UV flexographic printing. The absence of such requirements on quality parameters of the technological process of Narrow Web UV-Printing predetermined conducting its analysis with the help of expert surveys.

  17. Transparency or spectral narrowing for two-mode squeezing and entanglement

    International Nuclear Information System (INIS)

    Hu Xiangming; Oh, C. H.

    2011-01-01

    We analyze the nonadiabatic effects on the propagation of a two-mode squeezed field inside a medium of three-level Λ atoms that display the dark resonance. We identify the different effects for the two-mode quantum properties: (i) unconditional transparency for the sum squeezing and (ii) induced transparency or spectral narrowing for the difference squeezing depending on the relative widths of the initial correlation spectrum to the transparency window. These effects combine to induce transparency or spectrum narrowing for the bipartite entanglement. The potential applications range from quantum information to laser spectroscopy and frequency standards.

  18. A thermoluminescence study of mineral silicates extracted from herbs in the dose range 0.5–5 Gy

    International Nuclear Information System (INIS)

    Della Monaca, Sara; Fattibene, Paola; Bortolin, Emanuela

    2013-01-01

    The presence of silicates in many personal objects suggests their potential use at low dose as fortuitous dosimeter in an accidental radiological exposure, when conventional dosimetry is not available. The goal of the present work is the dosimetric characterization of mineral silicates extracted from the plant Hibiscus Sabdariffa L, known as Jamaica flower, in the dose range 0.5–5 Gy. By studying the radiation-induced signal in time, the temperature integration region between 210 °C and 250 °C was found to be the most stable and also reduced the effects of thermal fading in the dose reconstruction process; the dose response curve was linear between 0.5 Gy and 5 Gy. By checking the change in sensitivity after repeated exposures to ionizing radiations and to high temperature heating, no variation in the glow curve shape or peak intensities were detected. To eliminate a pre-existing background signal, all the characterization measurements were performed with aliquots “annealed” by a preliminary readout of the TL. - Highlights: • Glow curves change in shape and intensity just in the first 3 days after irradiation. • The dose response is linear in the dose range 0.5–5 Gy. • The curve shape or intensity don't change after repeated exposures and heatings. • Encouraging results were obtained in the dose recovery test

  19. Investigations on MGy ionizing dose effects in thin oxides of micro-electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Gaillardin, M.; Paillet, P.; Raine, M.; Martinez, M.; Marcandella, C.; Duhamel, O.; Richard, N.; Leray, J.L. [CEA, DAM, DIF, F-91297 Arpajon (France); Goiffon, V.; Corbiere, F.; Rolando, S.; Molina, R.; Magnan, P. [ISAE, Universite de Toulouse, 10 avenue Edouard Belin, BP 54032, 31055 Toulouse Cedex 4 (France); Girard, S.; Ouerdane, Y.; Boukenter, A. [Universite de Saint-Etienne, Laboratoire H. Curien, UMR-5516, 42000, Saint-Etienne (France)

    2015-07-01

    Total ionizing dose (TID) effects have been studied for a long time in micro-electronic components designed to operate in natural and artificial environments. In most cases, TID induces both charge trapping in the bulk of irradiated oxides and the buildup of interface traps located at semiconductor/dielectric interfaces. Such effects result from basic mechanisms driven by both the shape of the electric field which stands into the oxide and by fabrication process parameters inducing pre-existing traps in the oxide's bulk. From the pioneering studies based on 'thick' oxide technologies to the most recent ones dedicated to innovative technologies, most studies concluded that the impact of total ionizing dose effects reduces with the oxide thinning. This is specifically the case for the gate-oxide of Metal-Oxide-Semiconductor Field Effect Transistors (MOSFET) for which it is generally considered that TID is not a major issue anymore at kGy dose ranges. TID effects are now mainly due to charge trapping in the field oxides such as Shallow Trench Isolation. This creates either parasitic conduction paths or Radiation-Induced Narrow Channel Effects (RINCE). Static current-voltage (I-V) electrical characteristics are then modified through a significant increase of the off-current of NMOS transistors or by shifting the whole I-V curves (of both NMOS and PMOS transistors). Based on these assumptions, no significant shift of I-V curves should be observed in modern bulk CMOS technologies. However, such phenomenon may not be directly extrapolated to higher TID ranges, typically of several MGy for which only few data are available in the literature. This paper presents evidences of large threshold voltage shifts measured at MGy dose levels despite the fact that transistors are designed in a submicron bulk technology which features a 7-nm thin gate-oxide on GO2 transistors dedicated to mixed analog/digital integrated circuits. Such electrical shifts are encountered

  20. Investigations on MGy ionizing dose effects in thin oxides of micro-electronic devices

    International Nuclear Information System (INIS)

    Gaillardin, M.; Paillet, P.; Raine, M.; Martinez, M.; Marcandella, C.; Duhamel, O.; Richard, N.; Leray, J.L.; Goiffon, V.; Corbiere, F.; Rolando, S.; Molina, R.; Magnan, P.; Girard, S.; Ouerdane, Y.; Boukenter, A.

    2015-01-01

    Total ionizing dose (TID) effects have been studied for a long time in micro-electronic components designed to operate in natural and artificial environments. In most cases, TID induces both charge trapping in the bulk of irradiated oxides and the buildup of interface traps located at semiconductor/dielectric interfaces. Such effects result from basic mechanisms driven by both the shape of the electric field which stands into the oxide and by fabrication process parameters inducing pre-existing traps in the oxide's bulk. From the pioneering studies based on 'thick' oxide technologies to the most recent ones dedicated to innovative technologies, most studies concluded that the impact of total ionizing dose effects reduces with the oxide thinning. This is specifically the case for the gate-oxide of Metal-Oxide-Semiconductor Field Effect Transistors (MOSFET) for which it is generally considered that TID is not a major issue anymore at kGy dose ranges. TID effects are now mainly due to charge trapping in the field oxides such as Shallow Trench Isolation. This creates either parasitic conduction paths or Radiation-Induced Narrow Channel Effects (RINCE). Static current-voltage (I-V) electrical characteristics are then modified through a significant increase of the off-current of NMOS transistors or by shifting the whole I-V curves (of both NMOS and PMOS transistors). Based on these assumptions, no significant shift of I-V curves should be observed in modern bulk CMOS technologies. However, such phenomenon may not be directly extrapolated to higher TID ranges, typically of several MGy for which only few data are available in the literature. This paper presents evidences of large threshold voltage shifts measured at MGy dose levels despite the fact that transistors are designed in a submicron bulk technology which features a 7-nm thin gate-oxide on GO2 transistors dedicated to mixed analog/digital integrated circuits. Such electrical shifts are encountered

  1. Narrow, duplicated internal auditory canal

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, T. [Servico de Neurorradiologia, Hospital Garcia de Orta, Avenida Torrado da Silva, 2801-951, Almada (Portugal); Shayestehfar, B. [Department of Radiology, UCLA Oliveview School of Medicine, Los Angeles, California (United States); Lufkin, R. [Department of Radiology, UCLA School of Medicine, Los Angeles, California (United States)

    2003-05-01

    A narrow internal auditory canal (IAC) constitutes a relative contraindication to cochlear implantation because it is associated with aplasia or hypoplasia of the vestibulocochlear nerve or its cochlear branch. We report an unusual case of a narrow, duplicated IAC, divided by a bony septum into a superior relatively large portion and an inferior stenotic portion, in which we could identify only the facial nerve. This case adds support to the association between a narrow IAC and aplasia or hypoplasia of the vestibulocochlear nerve. The normal facial nerve argues against the hypothesis that the narrow IAC is the result of a primary bony defect which inhibits the growth of the vestibulocochlear nerve. (orig.)

  2. Flooding correlations in narrow channel

    International Nuclear Information System (INIS)

    Kim, S. H.; Baek, W. P.; Chang, S. H.

    1999-01-01

    Heat transfer in narrow gap is considered as important phenomena in severe accidents in nuclear power plants. Also in heat removal of electric chip. Critical heat flux(CHF) in narrow gap limits the maximum heat transfer rate in narrow channel. In case of closed bottom channel, flooding limited CHF occurrence is observed. Flooding correlations will be helpful to predict the CHF in closed bottom channel. In present study, flooding data for narrow channel geometry were collected and the work to recognize the effect of the span, w and gap size, s were performed. And new flooding correlations were suggested for high-aspect-ratio geometry. Also, flooding correlation was applied to flooding limited CHF data

  3. Quantifying the Effectiveness of Dose Individualization by Simulation for a Drug With Moderate Pharmacokinetic Variability.

    Science.gov (United States)

    Liefaard, Lia; Chen, Chao

    2015-10-01

    Dose individualization can reduce variability in exposure. The objective of this work was to quantify, through pharmacokinetic (PK) simulation, the potential for reducing the variability in exposure by dose individualization for a drug with moderate PK variability between subjects and between occasions within a subject, and a narrow therapeutic window. Using a population PK model that includes between-subject and between-occasion variability for apparent clearance, individual PK profiles in a trial of 300 subjects after a test dose were simulated. From the simulated data, datasets were created mimicking various sampling regimens (from single predose sample to full profile samples over 12 hours) on 1 or more occasions (1, 2, 3, 5, or 10 visits). Using these datasets, individual apparent clearance values were estimated, which were then used to calculate an individualized dose for a predefined target area under the concentration-time curve (AUC), based on the available formulation strengths. The proportion of people whose mean AUC was within a predefined therapeutic AUC range was calculated for the test (before) and the individualized dose (after), and compared between the different sampling scenarios. The maximum increase in proportion of subjects with an AUC within the range was 20%. To achieve this benefit, PK samples over 4 hours from 100 dosing occasions were required. As a result of the dose adjustment, the AUC of 7.3% of the subjects moved from inside the therapeutic range to outside of the range. This work shows how modeling and simulation can help assess the benefit and risk of dose individualization for a compound with variability between subjects and between occasions. The framework can be applied to similar situations with a defined set of conditions (eg, therapeutic window, tablet strengths, and PK and/or pharmacodynamic sampling scheme) to inform dose change and to assess the utility of dose individualization against certain success criteria.

  4. Controllable ultra-narrow fluorescence and six-wave mixing under double electromagnetically induced transparency

    International Nuclear Information System (INIS)

    Wang, Z G; Zhang, Z Y; Che, J L; Zhang, Y Z; Li, C B; Zheng, H B; Zhang, Y P

    2013-01-01

    We report the first observation of six-wave mixing (SWM) and fluorescence signals in an electromagnetically induced transparency (EIT) window. Several remarkable advantages are described. First, multiple bright and dark states are simultaneously observed due to enhancement or suppression of the SWM signal. Second, ultra-narrow fluorescence, much narrower than the EIT window, is experimentally obtained. Third, the ultra-narrow fluorescence can also generate Autler–Townes splitting on scanning the coupling beam. Fourth, a double-peak EIT window is obtained using the nest-dressing scheme. Such studies concerning SWM and fluorescence have applications in optical switching, multi-channel communication and narrowband and long-range quantum communication. (letter)

  5. Search for narrow resonances in e+e- annihilation at PETRA

    International Nuclear Information System (INIS)

    Berger, C.; Genzel, H.; Grigull, R.; Lackas, W.; Raupach, F.; Ackermann, H.

    1980-01-01

    We have performed a search for narrow-resonances in the center of mass energy range from 29.90 to 31.46 GeV using the e + e - storage ring PETRA at DESY. We present the total cross section for hadron production and an upper limit for resonance production, indicating that no bound state of charge 2/3 quarks exists in this energy range. (orig.) 891 HSI/orig. 892 MKO

  6. Normal range of human dietary sodium intake

    DEFF Research Database (Denmark)

    McCarron, David A; Kazaks, Alexandra G; Geerling, Joel C

    2013-01-01

    The recommendation to restrict dietary sodium for management of hypertensive cardiovascular disease assumes that sodium intake exceeds physiologic need, that it can be significantly reduced, and that the reduction can be maintained over time. In contrast, neuroscientists have identified neural...... circuits in vertebrate animals that regulate sodium appetite within a narrow physiologic range. This study further validates our previous report that sodium intake, consistent with the neuroscience, tracks within a narrow range, consistent over time and across cultures....

  7. DNB Mechanistic model assessment based on experimental data in narrow rectangular channel

    International Nuclear Information System (INIS)

    Zhou Lei; Yan Xiao; Huang Yanping; Xiao Zejun; Huang Shanfang

    2011-01-01

    The departure from nuclear boiling (DNB) is important concerning about the safety of a PWR. Lacking assessment by experimental data points, it's doubtful whether the existing models can be used in narrow rectangular channels or not. Based on experimental data points in narrow rectangular channels, two kinds of classical DNB models, which include liquid sublayer dryout model (LSDM) and bubble crowding model (BCM), were assessed. The results show that the BCM has much wider application range than the LSDM. Several thermal parameters show systematical influences on the calculated results by the models. The performances of all the models deteriorate as the void fraction increases. The reason may be attributed to the geometrical differences between a circular tube and narrow rectangular channel. (authors)

  8. Is It Better to Enter a Volume CT Dose Index Value before or after Scan Range Adjustment for Radiation Dose Optimization of Pediatric Cardiothoracic CT with Tube Current Modulation?

    Science.gov (United States)

    2018-01-01

    Objective To determine whether the body size-adapted volume computed tomography (CT) dose index (CTDvol) in pediatric cardiothoracic CT with tube current modulation is better to be entered before or after scan range adjustment for radiation dose optimization. Materials and Methods In 83 patients, cardiothoracic CT with tube current modulation was performed with the body size-adapted CTDIvol entered after (group 1, n = 42) or before (group 2, n = 41) scan range adjustment. Patient-related, radiation dose, and image quality parameters were compared and correlated between the two groups. Results The CTDIvol after the CT scan in group 1 was significantly higher than that in group 2 (1.7 ± 0.1 mGy vs. 1.4 ± 0.3 mGy; p Hounsfield units [HU] vs. 4.5 ± 0.7 HU) and image quality (1.5 ± 0.6 vs. 1.5 ± 0.6) showed no significant differences between the two (p > 0.05). In both groups, all patient-related parameters, except body density, showed positive correlations (r = 0.49–0.94; p 0.05) in group 2. Conclusion In pediatric cardiothoracic CT with tube current modulation, the CTDIvol entered before scan range adjustment provides a significant dose reduction (18%) with comparable image quality compared with that entered after scan range adjustment.

  9. Photogrammetric measurement of 3D freeform millimetre-sized objects with micro features: an experimental validation of the close-range camera calibration model for narrow angles of view

    Science.gov (United States)

    Percoco, Gianluca; Sánchez Salmerón, Antonio J.

    2015-09-01

    The measurement of millimetre and micro-scale features is performed by high-cost systems based on technologies with narrow working ranges to accurately control the position of the sensors. Photogrammetry would lower the costs of 3D inspection of micro-features and would be applicable to the inspection of non-removable micro parts of large objects too. Unfortunately, the behaviour of photogrammetry is not known when photogrammetry is applied to micro-features. In this paper, the authors address these issues towards the application of digital close-range photogrammetry (DCRP) to the micro-scale, taking into account that in literature there are research papers stating that an angle of view (AOV) around 10° is the lower limit to the application of the traditional pinhole close-range calibration model (CRCM), which is the basis of DCRP. At first a general calibration procedure is introduced, with the aid of an open-source software library, to calibrate narrow AOV cameras with the CRCM. Subsequently the procedure is validated using a reflex camera with a 60 mm macro lens, equipped with extension tubes (20 and 32 mm) achieving magnification of up to 2 times approximately, to verify literature findings with experimental photogrammetric 3D measurements of millimetre-sized objects with micro-features. The limitation experienced by the laser printing technology, used to produce the bi-dimensional pattern on common paper, has been overcome using an accurate pattern manufactured with a photolithographic process. The results of the experimental activity prove that the CRCM is valid for AOVs down to 3.4° and that DCRP results are comparable with the results of existing and more expensive commercial techniques.

  10. Photogrammetric measurement of 3D freeform millimetre-sized objects with micro features: an experimental validation of the close-range camera calibration model for narrow angles of view

    International Nuclear Information System (INIS)

    Percoco, Gianluca; Sánchez Salmerón, Antonio J

    2015-01-01

    The measurement of millimetre and micro-scale features is performed by high-cost systems based on technologies with narrow working ranges to accurately control the position of the sensors. Photogrammetry would lower the costs of 3D inspection of micro-features and would be applicable to the inspection of non-removable micro parts of large objects too. Unfortunately, the behaviour of photogrammetry is not known when photogrammetry is applied to micro-features.In this paper, the authors address these issues towards the application of digital close-range photogrammetry (DCRP) to the micro-scale, taking into account that in literature there are research papers stating that an angle of view (AOV) around 10° is the lower limit to the application of the traditional pinhole close-range calibration model (CRCM), which is the basis of DCRP.At first a general calibration procedure is introduced, with the aid of an open-source software library, to calibrate narrow AOV cameras with the CRCM. Subsequently the procedure is validated using a reflex camera with a 60 mm macro lens, equipped with extension tubes (20 and 32 mm) achieving magnification of up to 2 times approximately, to verify literature findings with experimental photogrammetric 3D measurements of millimetre-sized objects with micro-features. The limitation experienced by the laser printing technology, used to produce the bi-dimensional pattern on common paper, has been overcome using an accurate pattern manufactured with a photolithographic process.The results of the experimental activity prove that the CRCM is valid for AOVs down to 3.4° and that DCRP results are comparable with the results of existing and more expensive commercial techniques. (paper)

  11. Experimental study on saturated boiling of two phase natural circulation under low pressure in narrow rectangular channels

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zi-chao; Qi, Shi; Zhou, Tao; Li, Bing; Shahzad, Muhammad Ali [North China Electric Power Univ., Beijing (China). School of Nuclear Science and Engineering; Beijing Key Laboratory of Passive Safety Technology for Nuclear Energy, Beijing (China); Huang, Yan-ping [Nuclear Reactor Thermal Hydraulics Technology, Chengdu (China). CNNC Key Lab.

    2017-12-15

    Saturated boiling of two-phase natural circulation has been experimentally investigated based on a natural circulation device with narrow rectangular channels. When heating power reaches a certain range, it is possible to observe the phenomenon of saturated boiling and flow pattern transition in the system. The results show the heat transfer coefficient of saturated boiling decreases with the increasing of pressure, heating power and size of narrow rectangle channels. The buoyancy force causing mixed convection decreases the heat transfer coefficient. Finally, a dimensionless number is introduced, which reflects length to width ratio of rectangular narrow section and Rayleigh number, in order to revise the presented correlation. All errors fall within the range of ±15%.

  12. Dual-resolution dose assessments for proton beamlet using MCNPX 2.6.0

    Science.gov (United States)

    Chao, T. C.; Wei, S. C.; Wu, S. W.; Tung, C. J.; Tu, S. J.; Cheng, H. W.; Lee, C. C.

    2015-11-01

    The purpose of this study is to access proton dose distribution in dual resolution phantoms using MCNPX 2.6.0. The dual resolution phantom uses higher resolution in Bragg peak, area near large dose gradient, or heterogeneous interface and lower resolution in the rest. MCNPX 2.6.0 was installed in Ubuntu 10.04 with MPI for parallel computing. FMesh1 tallies were utilized to record the energy deposition which is a special designed tally for voxel phantoms that converts dose deposition from fluence. 60 and 120 MeV narrow proton beam were incident into Coarse, Dual and Fine resolution phantoms with pure water, water-bone-water and water-air-water setups. The doses in coarse resolution phantoms are underestimated owing to partial volume effect. The dose distributions in dual or high resolution phantoms agreed well with each other and dual resolution phantoms were at least 10 times more efficient than fine resolution one. Because the secondary particle range is much longer in air than in water, the dose of low density region may be under-estimated if the resolution or calculation grid is not small enough.

  13. Clonidine as an adjunct to intravenous regional anesthesia: A randomized, double-blind, placebo-controlled dose ranging study

    Directory of Open Access Journals (Sweden)

    Clarence S Ivie

    2011-01-01

    Full Text Available Background : The addition of clonidine to lidocaine intravenous regional anesthesia (IVRA has been previously reported to improve postoperative analgesia in patients undergoing upper extremity surgery. Our objective was to perform a dose ranging study in order to determine the optimal dose of clonidine used with lidocaine in IVRA. Design & Setting : We performed a double-blinded randomized placebo-controlled study with 60 patients scheduled for elective endoscopic carpal tunnel release under IVRA with 50 ml lidocaine 0.5%. University-affiliated outpatient surgery center. Data collected in operating rooms, recovery room, and by telephone after discharge from surgery center. Materials & Methods : Sixty adult ASA I or II patients undergoing outpatient endoscopic carpal tunnel release under intravenous regional anesthesia.Patients were randomized into five study groups receiving different doses of clonidine in addition to 50 ml 0.5% lidocaine in their IVRA. Group A received 0 mcg/kg, group B 0.25 mcg/kg, group C 0.5 mcg/kg, group D 1.0 mcg/kg and group E 1.5 mcg/kg of clonidine.Intraoperative fentanyl, recovery room pain scores, time to first postsurgical analgesic, total number of acetaminophen/codeine tablets consumed postsurgery, incidence of sedation, hypotension and bradycardia. Results & Conclusions : There was no benefit from any dose of clonidine compared to placebo. There were no clonidine-related side effects seen within the dose range studied. In short duration minor hand surgery, the addition of clonidine to lidocaine-based intravenous regional anesthesia provides no measurable benefit.

  14. Definition of Quality Criteria of the Technological Process of Narrow Web UV-Printing

    OpenAIRE

    Volodymyr Shybanov; Vsevolod Senkivsky; Vyacheslav Repeta; Natalia Gurgal

    2013-01-01

    The application of Narrow Web UV-flexographic printing has several advantages compared with offset printing. In particular, they are the lack of the operation of water-ink balance setting in the technological process, the ability to print on a wide range of materials and so on. Though the imprint quality is clearly based on standards in offset printing, there are no clearly indicated requirements for Narrow Web UV flexographic printing. The absence of such requirements on quality parameters o...

  15. Broad Anatomical Variation within a Narrow Wood Density Range--A Study of Twig Wood across 69 Australian Angiosperms.

    Directory of Open Access Journals (Sweden)

    Kasia Ziemińska

    Full Text Available Just as people with the same weight can have different body builds, woods with the same wood density can have different anatomies. Here, our aim was to assess the magnitude of anatomical variation within a restricted range of wood density and explore its potential ecological implications.Twig wood of 69 angiosperm tree and shrub species was analyzed. Species were selected so that wood density varied within a relatively narrow range (0.38-0.62 g cm-3. Anatomical traits quantified included wood tissue fractions (fibres, axial parenchyma, ray parenchyma, vessels, and conduits with maximum lumen diameter below 15 μm, vessel properties, and pith area. To search for potential ecological correlates of anatomical variation the species were sampled across rainfall and temperature contrasts, and several other ecologically-relevant traits were measured (plant height, leaf area to sapwood area ratio, and modulus of elasticity.Despite the limited range in wood density, substantial anatomical variation was observed. Total parenchyma fraction varied from 0.12 to 0.66 and fibre fraction from 0.20 to 0.74, and these two traits were strongly inversely correlated (r = -0.86, P < 0.001. Parenchyma was weakly (0.24 ≤|r|≤ 0.35, P < 0.05 or not associated with vessel properties nor with height, leaf area to sapwood area ratio, and modulus of elasticity (0.24 ≤|r|≤ 0.41, P < 0.05. However, vessel traits were fairly well correlated with height and leaf area to sapwood area ratio (0.47 ≤|r|≤ 0.65, all P < 0.001. Modulus of elasticity was mainly driven by fibre wall plus vessel wall fraction rather than by the parenchyma component.Overall, there seem to be at least three axes of variation in xylem, substantially independent of each other: a wood density spectrum, a fibre-parenchyma spectrum, and a vessel area spectrum. The fibre-parenchyma spectrum does not yet have any clear or convincing ecological interpretation.

  16. Homeostatic balance as an indicator of prolonged technogenic exposure in low dose range

    International Nuclear Information System (INIS)

    Karpov, A.B.; Voronova, I.A.; Takhauov, R.M.; Semyonova, Yu.V.; Sherstoboev, E.Yu.; Udut, V.V.

    2008-01-01

    Full text: Indication of changes induced by ionizing radiation starting up a wide range of pathologic reactions in the disease developments still poses a significant problem in radiation medicine. It mainly concerns exposure to low dose-rate ionizing radiation, since its effects are still open to question, and today any researcher acknowledges that radiation induced pathological changes can accumulate at both subclinical and prenosological stages and develop not only in exposed persons, but also in their offspring. The subject of this study was workers of reactor and radiochemical productions of Siberian Group of Chemical Enterprises (SGCE) exposed to external and combined (external and internal) radiation respectively. Two comparative groups were formed: reactor and radiochemical production workers. In the reactor production group of workers the cumulative dose of external γ-radiation was up to 300 mSv, in the radiochemical production group - up to 150 mSv. Age ranged from 40 to 50 years. The two groups were compared between each other. Above all, there were formed 'insider control' groups (workers of the same productions with zero doses) to assess the impact of radiation factor on central homeostatic mechanisms. These groups were created using pair technique in order to level somatic disorders influence on the parameters under study. Numbers of full and biochemical blood examinations, energy metabolism between cells, hormones of homeostasis by the adaptive hormone level - insulin and cortisol, lipid peroxidation and antioxidant protection systems, immune and vegetative systems were all analyzed. Analyses of the systems performed, it was found out that in persons having been exposed to long term occupational radiation there were significant changes indicating lipid peroxidation system activation, antioxidant protection system depression, as well as lowered energy metabolism. The higher external γ-doses the bigger these changes are. Results from the two groups of

  17. Dynamic film thickness between bubbles and wall in a narrow channel

    Science.gov (United States)

    Ito, Daisuke; Damsohn, Manuel; Prasser, Horst-Michael; Aritomi, Masanori

    2011-09-01

    The present paper describes a novel technique to characterize the behavior of the liquid film between gas bubbles and the wall in a narrow channel. The method is based on the electrical conductance. Two liquid film sensors are installed on both opposite walls in a narrow rectangular channel. The liquid film thickness underneath the gas bubbles is recorded by the first sensor, while the void fraction information is obtained by measuring the conductance between the pair of opposite sensors. Both measurements are taken on a large two-dimensional domain and with a high speed. This makes it possible to obtain the two-dimensional distribution of the dynamic liquid film between the bubbles and the wall. In this study, this method was applied to an air-water flow ranging from bubbly to churn regimes in the narrow channel with a gap width of 1.5 mm.

  18. Accuracy and Radiation Dose Reduction of Limited-Range CT in the Evaluation of Acute Appendicitis in Pediatric Patients.

    Science.gov (United States)

    Jin, Michael; Sanchez, Thomas R; Lamba, Ramit; Fananapazir, Ghaneh; Corwin, Michael T

    2017-09-01

    The purpose of this article is to determine the accuracy and radiation dose reduction of limited-range CT prescribed from the top of L2 to the top of the pubic symphysis in children with suspected acute appendicitis. We performed a retrospective study of 210 consecutive pediatric patients from December 11, 2012, through December 11, 2014, who underwent abdominopelvic CT for suspected acute appendicitis. Two radiologists independently reviewed the theoretic limited scans from the superior L2 vertebral body to the top of the pubic symphysis, to assess for visualization of the appendix, acute appendicitis, alternative diagnoses, and incidental findings. Separately, the same parameters were assessed on the full scan by the same two reviewers. Whole-body effective doses were determined for the full- and limited-range scans and were compared using the paired t test. The appendix or entire cecum was visualized on the limited scan in all cases, and no cases of acute appendicitis were missed on the simulated limited scan compared with the full scan. Two alternative diagnoses were missed with the limited scan: one case of hydronephrosis and one of acute acalculous cholecystitis. The mean effective dose for the original scan was 5.6 mSv and that for the simulated limited scan was 3.0 mSv, resulting in a dose reduction of 46.4% (p appendicitis and reduces the dose by approximately 46%.

  19. On the use of differential solubility in aqueous ethanol solutions to narrow the DP range of food-grade starch hydrolysis products.

    Science.gov (United States)

    Balto, Amy S; Lapis, Trina J; Silver, Rachel K; Ferreira, Andrew J; Beaudry, Christopher M; Lim, Juyun; Penner, Michael H

    2016-04-15

    Considerable research is focused on understanding the functionality of starch hydrolysis products (SHP) consisting of glucose, maltose, maltooligosaccharides (MOS), and maltopolysaccharides (MPS). A confounding factor in this research is the high molecular dispersity of commercially available SHP. The study presented herein characterizes a flexible fractionation approach for lowering the dispersity of such products. This was accomplished by fractionating a corn syrup solids (CSS) preparation based on the differential solubility of its component saccharides in aqueous-ethanol solutions. Products obtained from selected fractionations were characterized with respect to degree of polymerization (DP; liquid chromatography), dextrose equivalency (reducing sugar assays), and prevalence of branching (NMR). Glucose and maltose were preferentially removed from CSS using high (⩾90%) ethanol extractants. Preparations with relatively narrow ranges of MOS, lower DP MPS, and higher DP MPS were obtained through repetitive 70%-ethanol extractions. Linear, as opposed to branched, MOS and MPS were preferentially extracted under all conditions tested. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Effects of gamma radiation in a wide range of doses on the morphological characteristics of Lemna minor L

    International Nuclear Information System (INIS)

    Rasskazova, M.M.; Berestina, A.V.

    2011-01-01

    The effects of gamma radiation on the morphological parameters of Lemna minor L. were studied. As the sensitive parameters were invited to use chlorosis and necrosis. Significant differences between samples begin to show after 14 days of observation. The presence of effect, irrespective of the dose in the range 0,1-30 Gy, shows the efficiency of a sufficiently small dose (0,1 Gy) was revealed.

  1. Preliminary evaluation of second harmonic direct detection scheme for low-dose range in alanine/EPR dosimetry

    International Nuclear Information System (INIS)

    Chen, Felipe; Graeff, Carlos F.O.; Baffa, Oswaldo

    2002-01-01

    The usefulness of a direct detection scheme of the second harmonic (2h) overmodulated signal from irradiated alanine in EPR dosimetry was studied. For this purpose, a group of DL-alanine/paraffin cylindrical pellets was produced. The dosimeters were irradiated with a 60 Co radiotherapy gamma source with doses of 0.05, 0.1, 0.5, 1 and 5 Gy. The EPR measurements were carried out in a VARIAN-E4 spectrometer operating in X-band with optimized parameters to obtain highest amplitude signals of both harmonics. The 2h signal was detected directly at twice the modulation frequency. In preliminary results, the 2h showed some advantages over the 1h such as better resolution for doses below 1 Gy, better repeatability results and better linear behaviour in the dose range indicated. (author)

  2. Radiation-induced polymerization of water-saturated styrene in a wide range of dose rate

    International Nuclear Information System (INIS)

    Takezaki, J.; Okada, T.; Sakurada, I.

    1978-01-01

    Radiation-induced polymerization of water-saturated styrene (water content 3.5 x 10 -2 mole/liter) was carried out in a wide range of dose rate between 1.2 x 10 3 and 1.8 x 10 7 rad/sec, and compared with the polymerization of the moderately dried styrene (water content 3.2 x 10 -3 mole/liter). Molecular weight distribution curves of the polymerization products showed that they were generally consisted of four parts, namely, oligomers, radical, cationic, and super polymers. Contributions of the four constituents to the polymerization and the number average degrees of polymerization (DP) of the four kinds of polymers were calculated by the graphical analysis of the curves. The rate of radical polymerization and DP of radical polymers are independent of the water content; the dose rate dependences of the polymerization rate and DP agree with the well known square root and inverse square root laws, respectively, of the radical polymerization of styrene. The rate of ionic polymerization is directly proportional to the dose rate, but it decreases, at a given dose rate, inversely proportional to the water content of styrene. DP of ionic polymer is independent of the dose rate but decreases with increasing water content. The super polymer of DP about 10 4 is not formed in the case of the moderately dried styrene. G values for the initiating radical and ion formation are calculated to be independently of the dose rate and water content, 0.66 and 0.027, respectively. It was suggested that oligomer was formed in the early stage by the interaction of cation with anion and only those cations which had survived underwent polymerization. 10 figures, 4 tables

  3. Changes in Rectal Dose Due to Alterations in Beam Angles for Setup Uncertainty and Range Uncertainty in Carbon-Ion Radiotherapy for Prostate Cancer.

    Directory of Open Access Journals (Sweden)

    Yoshiki Kubota

    Full Text Available Carbon-ion radiotherapy of prostate cancer is challenging in patients with metal implants in one or both hips. Problems can be circumvented by using fields at oblique angles. To evaluate the influence of setup and range uncertainties accompanying oblique field angles, we calculated rectal dose changes with oblique orthogonal field angles, using a device with fixed fields at 0° and 90° and a rotating patient couch.Dose distributions were calculated at the standard angles of 0° and 90°, and then at 30° and 60°. Setup uncertainty was simulated with changes from -2 mm to +2 mm for fields in the anterior-posterior, left-right, and cranial-caudal directions, and dose changes from range uncertainty were calculated with a 1 mm water-equivalent path length added to the target isocenter in each angle. The dose distributions regarding the passive irradiation method were calculated using the K2 dose algorithm.The rectal volumes with 0°, 30°, 60°, and 90° field angles at 95% of the prescription dose were 3.4±0.9 cm3, 2.8±1.1 cm3, 2.2±0.8 cm3, and 3.8±1.1 cm3, respectively. As compared with 90° fields, 30° and 60° fields had significant advantages regarding setup uncertainty and significant disadvantages regarding range uncertainty, but were not significantly different from the 90° field setup and range uncertainties.The setup and range uncertainties calculated at 30° and 60° field angles were not associated with a significant change in rectal dose relative to those at 90°.

  4. Analysis on Longitudinal Dose according to Change of Field Width

    International Nuclear Information System (INIS)

    Jung, Won Seok; Shin, Ryung Mi; Oh, Byung Cheon; Jo, Jun Young; Kim, Gi Chul; Choi, Tae Gu; Back, Jong Geal

    2011-01-01

    To analyze the accuracy of tumor volume dose following field width change, to check the difference of dose change by using self-made moving car, and to evaluate practical delivery tumor dose when tomotherapy in the treatment of organ influenced by breathing. By using self-made moving car, the difference of longitudinal movement (0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm) was applied and compared calculated dose with measured dose according to change of field width (1.05 cm, 2.50 cm, 5.02 cm) and apprehended margin of error. Then done comparative analysis in degree of photosensitivity of DQA film measured by using Gafchromic EBT film. Dose profile and Gamma histogram were used to measure degree of photosensitivity of DQA film. When field width were 1.05 cm, 2.50 cm, 5.02 cm, margin of error of dose delivery coefficient was -2.00%, -0.39%, -2.55%. In dose profile of Gafchromic EBT film's analysis, the movement of moving car had greater motion toward longitudinal direction and as field width was narrower, big error increased considerably at high dose part compared to calculated dose. The more field width was narrowed, gamma index had a large considerable influence of moving at gamma histogram. We could check the difference of longitudinal dose of moving organ. In order to small field width and minimize organ moving due to breathing, it is thought to be needed to develop breathing control unit and fixation tool.

  5. Narrow-band radio flares from red dwarf stars

    Science.gov (United States)

    White, Stephen M.; Kundu, Mukul R.; Jackson, Peter D.

    1986-01-01

    VLA observations of narrow-band behavior in 20 cm flares from two red dwarf stars, L726 - 8A and AD Leo, are reported. The flare on L726 - 8A was observed at 1415 and 1515 MHz; the flux and the evolution differed significantly at the two frequencies. The flare on AD Leo lasted for 2 hr at 1415 MHz but did not appear at 1515 MHz. The AD Leo flare appears to rule out a source drifting through the stellar corona and is unlikely to be due to plasma emission. In the cyclotron maser model the narrow-band behavior reflects the range of magnetic fields present within the source. The apparent constancy of this field for 2 hr is difficult to understand if magnetic reconnection is the source of energy for the flare. The consistent polarization exhibited by red dwarf flares at 20 cm may be related to stellar activity cycles, and changes in this polarization will permit measuring the length of these cycles.

  6. Joint Space Narrowing in Patients With Pisotriquetral Osteoarthritis.

    Science.gov (United States)

    Ten Berg, Paul W L; Heeg, Erik; Strackee, Simon D; Streekstra, Geert J

    2017-09-01

    Patients with suspected pisotriquetral osteoarthritis may show joint space narrowing. However, the extent of joint space narrowing and its deviation from the joint space width (JSW) in normal anatomy is unknown. In this pathoanatomic study, we therefore compared the JSW in the pisotriquetral joint between osteoarthritic patient wrists and healthy wrists. We reviewed preoperative computed tomography (CT) scans of 8 wrists of patients with ulnar-sided wrist pain who underwent a pisiformectomy with confirmed pisotriquetral osteoarthritis at surgery. We also reviewed CT scans of 20 normal wrists from healthy volunteers serving as control group. Three-dimensional CT models of the pisiform and triquetrum were obtained from both affected and normal wrists, after which the minimum JSW was calculated in an automated fashion. In the patient group, the median (interquartile range) of the minimum JSW was 0.1 mm (0.0-0.2), and in the control group, 0.8 mm (0.3-0.9) ( P = .007). We showed that the pisotriquetral joint space in osteoarthritic patient wrists was significantly narrowed compared with healthy wrists. These results suggest that JSW evaluation has a potential diagnostic value in the work-up of patients with suspected pisotriquetral osteoarthritis. This is an interesting area for future clinical research, especially because no gold standard for diagnosing pisotriquetral osteoarthritis has been established yet.

  7. Effects of high neutron doses and duration of the chemical etching on the optical properties of CR-39

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Paul, S.; Sharma, S.C.; Joshi, D.S.; Gupta, A.K.; Bandyopadhyay, T.

    2015-01-01

    Effects of the duration of chemical etching on the transmittance, absorbance and optical band gap width of the CR-39 (Polyallyl diglycol carbonate) detectors irradiated to high neutron doses (12.7, 22.1, 36.0 and 43.5 Sv) were studied. The neutrons were produced by bombardment of a thick Be target with 12 MeV protons of different fluences. The unirradiated and neutron-irradiated CR-39 detectors were subjected to a stepwise chemical etching at 1 h intervals. After each step, the transmission spectra of the detectors were recorded in the range from 200 to 900 nm, and the absorbances and optical band gap widths were determined. The effect of the etching on the light transmittance of unirradiated detectors was insignificant, whereas it was very significant in the case of the irradiated detectors. The dependence of the optical absorbance on the neutron dose is linear at short etching periods, but exponential at longer ones. The optical band gap narrows with increasing etching time. It is more significant for the irradiated dosimeters than for the unirradiated ones. The rate of the narrowing of the optical band gap with increasing neutron dose increases with increasing duration of the etching. - Highlights: • The variation of optical properties of CR-39 at very high neutron dose is analyzed. Etching process is found to play a crucial role for change in optical properties of neutron-irradiated CR-39. • The optical absorbance varies linearly at lower dose, at very high dose absorbance saturation occurs. The dose at which saturation absorbance is observed shifts towards lower neutron dose with increase in etching time. • The rate of decrease in optical band gap with respect to neutron dose is found to be more at higher etching durations

  8. Dosimetric properties of the 'Pille' portable, wide dose range TLD reader

    International Nuclear Information System (INIS)

    Szabo, P.P.; Feher, I.; Deme, S.; Szabo, B.; Vagvoelgyi, J.

    1986-01-01

    The dosimetric properties of a portable TLD reader are described. The TLD system named 'Pille' or 'moth' consists of a lightweight battery-operated portable TLD reader and its CaSO 4 :Dy bulb dosemeters. The reproducibility of the TLD system at constant temperature was found to be better than + -2%, and the mean time between failures exceeded 5 years. The dose range of the system is wide, covering more than 6 orders of magnitude, from 5 μGy to 10 Gy. The energy dependence of the CaSO 4 :Dy bulb dosemeters is less than + - 20% above 100 keV in the energy compensation capsules. Without additional annealing, the bulb dosemeters can be re-used at least 100 times, which is an important aspect during in situ measurements. (author)

  9. Observation and Analysis of Anti-cancer Drug Use and Dose ...

    African Journals Online (AJOL)

    As all anti-cancer drugs are of narrow therapeutic window so dose individualization is required to be done. A study was conducted to check the use of anti-cancer drugs in the local anti-cancer facility of Bahawalpur i.e. Bahawalpur Institute of Nuclear Medicine and Oncology (BINO). In this study, the dose individualization ...

  10. Phototherapy UVB narrow band treatment of psoriasis, mycosis fungoides and vitiligo

    International Nuclear Information System (INIS)

    Reyes, M.V.; Kutnizky, R.; Bosch, M.P.; Ruiz Lascano, A.

    2013-01-01

    Introduction: Numerous studies have shown the beneficial effect of ultraviolet radiation for the treatment of lymphoproliferative or inflammatory skin diseases. Objective: To determine the response to UVB narrow band (UVB-nb) in psoriasis, mycosis fungoides stage IA, IB and vitiligo, in the Dermatology Department of Hospital Privado from May 2009 to January 2011. To correlate total energy dose used and the total number of sessions with the response achieved in each disease. To describe adverse reactions; determine demographic characteristics of the population and comorbidities in psoriasis and vitiligo. Material and Methods: We performed a prospective, descriptive, analytical, observational study. We included all patients assessed for initiation of UVB-nb. Regarding the patients who did not start or interrupted the treatment a survey was conducted to assess the causes. We calculated the cumulative dose and number of sessions at the end of treatment. (authors) [es

  11. Radiotherapy in addition to radical surgery in rectal cancer: evidence for a dose-response effect favoring preoperative treatment

    International Nuclear Information System (INIS)

    Glimelius, Bengt; Isacsson, Ulf; Jung, Bo; Paahlman, Lars

    1997-01-01

    Purpose: This study explored the relationship between radiation dose and reduction in local recurrence rate after preoperative and postoperative radiotherapy in rectal cancer. Methods and Materials: All randomized trials initiated prior to 1988 comparing preoperative and postoperative radiotherapy with surgery alone or with each other were included. Local failure rates were available in 5626 randomized patients. The linear quadratic formula was used to compensate for different radiotherapy schedules. Results: For preoperative radiotherapy, a clear dose-response relationship could be established. For postoperative radiotherapy, the range of doses was narrow, and a dose-response relationship could not be demonstrated. At similar doses, preoperative radiotherapy appeared to be more efficient in reducing local failure rate than postoperative. The only trial comparing preoperative with postoperative radiotherapy confirms this notion. A 15-20 Gy higher dose may be required postoperatively than preoperatively to reach similar efficacy. Neither approach alone significantly influences survival, although it is likely that a small survival benefit may be seen after preoperative radiotherapy. Conclusions: The information from the entire randomized experience suggests that preoperative radiotherapy may be more dose efficient than postoperative radiotherapy

  12. Identification of GH15 Family Thermophilic Archaeal Trehalases That Function within a Narrow Acidic-pH Range.

    Science.gov (United States)

    Sakaguchi, Masayoshi; Shimodaira, Satoru; Ishida, Shin-Nosuke; Amemiya, Miko; Honda, Shotaro; Sugahara, Yasusato; Oyama, Fumitaka; Kawakita, Masao

    2015-08-01

    Two glucoamylase-like genes, TVN1315 and Ta0286, from the archaea Thermoplasma volcanium and T. acidophilum, respectively, were expressed in Escherichia coli. The gene products, TVN1315 and Ta0286, were identified as archaeal trehalases. These trehalases belong to the CAZy database family GH15, although they have putative (α/α)6 barrel catalytic domain structures similar to those of GH37 and GH65 family trehalases from other organisms. These newly identified trehalases function within a narrow range of acidic pH values (pH 3.2 to 4.0) and at high temperatures (50 to 60°C), and these enzymes display Km values for trehalose higher than those observed for typical trehalases. These enzymes were inhibited by validamycin A; however, the inhibition constants (Ki) were higher than those of other trehalases. Three TVN1315 mutants, corresponding to E408Q, E571Q, and E408Q/E571Q mutations, showed reduced activity, suggesting that these two glutamic acid residues are involved in trehalase catalysis in a manner similar to that of glucoamylase. To date, TVN1315 and Ta0286 are the first archaeal trehalases to be identified, and this is the first report of the heterologous expression of GH15 family trehalases. The identification of these trehalases could extend our understanding of the relationships between the structure and function of GH15 family enzymes as well as glycoside hydrolase family enzymes; additionally, these enzymes provide insight into archaeal trehalose metabolism. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  13. Jihadism, Narrow and Wide

    DEFF Research Database (Denmark)

    Sedgwick, Mark

    2015-01-01

    The term “jihadism” is popular, but difficult. It has narrow senses, which are generally valuable, and wide senses, which may be misleading. This article looks at the derivation and use of “jihadism” and of related terms, at definitions provided by a number of leading scholars, and at media usage....... It distinguishes two main groups of scholarly definitions, some careful and narrow, and some appearing to match loose media usage. However, it shows that even these scholarly definitions actually make important distinctions between jihadism and associated political and theological ideology. The article closes...

  14. Intersession reliability of self-selected and narrow stance balance testing in older adults.

    Science.gov (United States)

    Riemann, Bryan L; Piersol, Kelsey

    2017-10-01

    Despite the common practice of using force platforms to assess balance of older adults, few investigations have examined the reliability of postural screening tests in this population. We sought to determine the test-retest reliability of self-selected and narrow stance balance testing with eyes open and eyes closed in healthy older adults. Thirty older adults (>65 years) completed 45 s trials of eyes open and eyes closed stability tests using self-selected and narrow stances on two separate days (1.9 ± .7 days). Average medial-lateral center of pressure velocity was computed. The ICC results ranged from .74 to .86, and no significant systematic changes (P eyes open and closed balance testing using self-selected and narrow stances in older adults was established which should provide a foundation for the development of fall risk screening tests.

  15. Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels

    International Nuclear Information System (INIS)

    Lu Weiguo; Olivera, Gustavo H; Chen Mingli; Reckwerdt, Paul J; Mackie, Thomas R

    2005-01-01

    Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and various voxel sizes with a homogeneous phantom, and assume forward energy transportation only. Simulations with voxel size up to 1 cm show that the CCK algorithm has errors within 0.1% of the maximum gold standard dose. Real dose calculations use a heterogeneous slab phantom, both the 'broad' (5 x 5 cm 2 ) and the 'narrow' (1.2 x 1.2 cm 2 ) tomotherapy beams. Various voxel sizes (0.5 mm, 1 mm, 2 mm, 4 mm and 8 mm) are used for dose calculations. The results show that all three algorithms have negligible difference (0.1%) for the dose calculation in the fine resolution (0.5 mm voxels). But differences become significant when the voxel size increases. As for the DK or CK algorithm in the broad (narrow) beam dose calculation, the dose differences between the 0.5 mm voxels and the voxels up to 8 mm (4 mm) are around 10% (7%) of the maximum dose. As for the broad (narrow) beam dose calculation using the CCK algorithm, the dose differences between the 0.5 mm voxels and the voxels up to 8 mm (4 mm) are around 1% of the maximum dose. Among all three methods, the CCK algorithm

  16. Laser linewidth narrowing using transient spectral hole burning

    Energy Technology Data Exchange (ETDEWEB)

    Thiel, Charles W.; Cone, Rufus L. [Department of Physics, Montana State University, Bozeman, MT 59715 (United States); Böttger, Thomas, E-mail: tbottger@usfca.edu [Department of Physics and Astronomy, 2130 Fulton Street, University of San Francisco, San Francisco, CA 94117 (United States)

    2014-08-01

    We demonstrate significant narrowing of laser linewidths by high optical density materials with inhomogeneously broadened absorption. As a laser propagates through the material, the nonlinear spectral hole burning process causes a progressive self-filtering of the laser spectrum, potentially reaching values less than the homogeneous linewidth. The transient spectral hole dynamically adjusts itself to the instantaneous frequency of the laser, passively suppressing laser phase noise and side modes over the entire material absorption bandwidth without the need for electronic or optical feedback to the laser. Wide bandwidth laser phase noise suppression was demonstrated using Er{sup 3+} doped Y{sub 2}SiO{sub 5} and LiNbO{sub 3} at 1.5 μm by employing time-delayed self-heterodyne detection of an external cavity diode laser to study the spectral narrowing effect. Our method is not restricted to any particular wavelength or laser system and is attractive for a range of applications where ultra-low phase noise sources are required. - Highlights: • We demonstrate significant laser linewidths narrowing by high optical density materials. • Nonlinear spectral hole burning causes progressive self-filtering of laser spectrum. • Filter dynamically adjusts itself to the instantaneous frequency of the laser. • Demonstrated at 1.5 μm in Er{sup 3+} doped Y{sub 2}SiO{sub 5} and LiNbO{sub 3}. • Linewidth filtering is not restricted to any particular wavelength or laser system.

  17. Device Physics of Narrow Gap Semiconductors

    CERN Document Server

    Chu, Junhao

    2010-01-01

    Narrow gap semiconductors obey the general rules of semiconductor science, but often exhibit extreme features of these rules because of the same properties that produce their narrow gaps. Consequently these materials provide sensitive tests of theory, and the opportunity for the design of innovative devices. Narrow gap semiconductors are the most important materials for the preparation of advanced modern infrared systems. Device Physics of Narrow Gap Semiconductors offers descriptions of the materials science and device physics of these unique materials. Topics covered include impurities and defects, recombination mechanisms, surface and interface properties, and the properties of low dimensional systems for infrared applications. This book will help readers to understand not only the semiconductor physics and materials science, but also how they relate to advanced opto-electronic devices. The last chapter applies the understanding of device physics to photoconductive detectors, photovoltaic infrared detector...

  18. Onset of a nucleate boiling and incipient point of net vapor generation in narrow channel

    International Nuclear Information System (INIS)

    Hong, G.

    2014-01-01

    An experimental study on onset of nucleate boiling (ONB) and incipient point of net vapor generation (IPNVG) in narrow rectangular channel was presented. Flow direction in the channel was vertical upward. The experimental results indicate that the classical correlations of ONB for conventional channels were not suitable for the present narrow rectangular channel. The wall superheat needed to initiate boiling is found to be higher for the same given values of heat and mass flux. The experimental results of IPNVG indicate that the heat flux, triggering net vapor generation in narrow rectangular channel, is litter lower than that calculated by correlations for conventional channels. The relative prediction error of qIPNVG by Griffith model, Saha model and Sun model ranges from -17.9% to +9.6%. A new correlation was developed to predict the ONB in narrow rectangular channel. The proposed correlation predictions agreed well with the experimental data. (author)

  19. Radiolysis of aqueous solutions of ammonium bicarbonate over a large dose range

    International Nuclear Information System (INIS)

    Draganic, Z.D.; Draganic, I.G.; Negron-Mendoza, A.; Navarro-Gonzales, R.; Albarran-Sanchez, M.G.; Sehested, K.

    1986-12-01

    0 2 -free aqueous solutions of 0.05 mol dm -3 ammonium bicarbonate were studied after receiving various doses of 60 Co gammas (0.001-170 Mrd) or krd pulses of 10 MeV electrons. Formate, oxalate, formaldehyde and an unidentified polymer (M w 14000-16000 daltons) were found to be the main radiolytic products. A large initial yield of formate in the γ-radiolysis, G(HCOO - ) = 2.2, is due to the reaction CO 2 - + HCO 3 - ↔ HC00 - + CO 3 - . The efficiency of organic synthesis within the large dose range studied is low and is explained by efficient pathways to the reformation of bicarbonate, where the reaction CO 2 - + CO 3 - is particurlarly significant. Computer fitting of the data obtained in the γ-radiolysis and by pulsed electron beam experiments gives k(CO 2 - + HCO 3 - ) = (2 ± 0.4)x10 3 dm 3 mol -1 s -1 , k(CO 2 - + CO 3 - ) = (5 ± 1)x10 7 dm 3 mol -1 s -1 , k(NH 2 + = HCO 3 - ) 4 dm 3 mol -1 s -1 and k(NH 2 + CO 3 - ) = (1.5 ± 0.5)x10 9 dm 3 mol -1 s -1 . (author)

  20. The influence of non-radiation induced ESR background signal from paraffin-alanine probes for dosimetry in the radiotherapy dose range

    International Nuclear Information System (INIS)

    Wieser, A.; Lettau, C.; Fill, U.; Regulla, D.F.

    1993-01-01

    The yield of radicals induced by ionizing radiation in the amino acid alanine and its quantification by ESR spectroscopy has proven excellent reproducibility. Those radicals trapped in the crystal lattice are prevented from recombination providing a thermally very stable system. This allows alanine to be applied as a transfer dosemeter. With paraffin-alanine probes ESR dosimetry can be performed with a standard deviation of ± 0.5% in the dose range from 20 Gy up to 100 kGy. At 1 Gy dose level the error increases to ± 6%. This dose level is three orders of magnitude higher than the calculated detection threshold for alanine with modern X-band ESR spectrometers. It was found that the poor standard deviation at the 1 Gy dose level, is not mainly produced by a bad signal-to-noise ratio but by a variable non-radiation induced ESR background signal from the alanine probes within a batch. In the present study the main sources of error for ESR dosimetry in the dose range below 20 Gy were analyzed. The influences of the production process, UV light and humidity upon the ESR background signal from paraffin-alanine probes were investigated. Measurements are shown indicating a second stable structure of the alanine radical at room temperature. (author)

  1. Simulating threshold voltage shift of MOS devices due to radiation in the low-dose range

    CERN Document Server

    Wan Xin Heng; Gao Wen Yu; Huang Ru; Wang Yang Yuan

    2002-01-01

    An analytical MOSFET threshold voltage shift model due to radiation in the low-dose range has been developed for circuit simulations. Experimental data in the literature shows that the model predictions are in good agreement. It is simple in functional form and hence computationally efficient. It can be used as a basic circuit simulation tool for analysing MOSFET exposed to a nuclear environment up to about 1 Mrad(Si). In accordance with common believe, radiation induced absolute change of threshold voltage was found to be larger in irradiated PMOS devices. However, if the radiation sensitivity is defined in the way authors did it, the results indicated NMOS rather than PMOS devices are more sensitive, specially at low doses. This is important from the standpoint of their possible application in dosimetry

  2. US images encoding envelope amplitude following narrow band filtering

    International Nuclear Information System (INIS)

    Sommer, F.G.; Stern, R.A.; Chen, H.S.

    1986-01-01

    Ultrasonic waveform data from phantoms having differing scattering characteristics and from normal and cirrhotic human liver in vivo were recorded within a standardized dynamic range and filtered with narrow band filters either above or below the mean recorded ultrasonic center frequency. Images created by mapping the amplitudes of received ultrasound following such filtration permitted dramatic differentiation, not discernible in conventional US images, of phantoms having differing scattering characteristics, and of normal and cirrhotic human livers

  3. Critical unpairing currents in narrow niobium films

    International Nuclear Information System (INIS)

    Gershenzon, M.E.; Gubankov, V.N.

    1979-01-01

    Investigated are the dependences of critical currents of narrow ( with the width of W=0.5-15 μm) superconducting niobium films on temperature and a magnetic field. The proposed method of film production with the width of the 1μm order and with small edge inhomogeneities ((<=500 A) permitted to realize the Ginsburg-Landau unpairing currents in the wide range of temperatures. The correct comparison with the theory showed that the unpairing currents are observed if W(< or approximately) 2delta, where delta is the effective depth of the penetration of the perpendicular magnetic field

  4. Narrow-band radio flares from red dwarf stars

    Energy Technology Data Exchange (ETDEWEB)

    White, S.M.; Kundu, M.R.; Jackson, P.D.

    1986-12-01

    VLA observations of narrow-band behavior in 20 cm flares from two red dwarf stars, L726 - 8A and AD Leo, are reported. The flare on L726 - 8A was observed at 1415 and 1515 MHz; the flux and the evolution differed significantly at the two frequencies. The flare on AD Leo lasted for 2 hr at 1415 MHz but did not appear at 1515 MHz. The AD Leo flare appears to rule out a source drifting through the stellar corona and is unlikely to be due to plasma emission. In the cyclotron maser model the narrow-band behavior reflects the range of magnetic fields present within the source. The apparent constancy of this field for 2 hr is difficult to understand if magnetic reconnection is the source of energy for the flare. The consistent polarization exhibited by red dwarf flares at 20 cm may be related to stellar activity cycles, and changes in this polarization will permit measuring the length of these cycles. 22 references.

  5. Evaluation of GAFCHROMIC EBT2 dosimetry for the low dose range using a flat-bed scanner with the reflection mode

    International Nuclear Information System (INIS)

    Gotanda, Tatsuhiro; Katsuda, Toshizo; Akagawa, Takuya; Gotanda, Rumi; Tabuchi, Akihiko; Yamamoto, Kenyu; Kuwano, Tadao; Takedo, Yoshihiro; Yatake, Hidetoshi; Yabunaka, Koichi

    2013-01-01

    Recently developed radiochromic films can easily be used to measure absorbed doses because they do not need development processing and indicate a density change that depends on the absorbed dose. However, in GAFCHROMIC EBT2 dosimetry (GAF-EBT2) as a radiochromic film, the precision of the measurement was compromised, because of non-uniformity problems caused by image acquisition using a flat-bed scanner with a transmission mode. The purpose of this study was to improve the precision of the measurement using a flat-bed scanner with a reflection mode at the low absorbed dose dynamic range of GAF-EBT2. The calibration curves of the absorbed dose versus the film density for GAF-EBT2 were provided. X-rays were exposed in the range between ~0 and 120 mGy in increments of about 12 mGy. The results of the method using a flat-bed scanner with the transmission mode were compared with those of the method using the same scanner with the reflection mode. The results should that the determination coefficients (r 2 ) for the straight-line approximation of the calibration curve using the reflection mode were higher than 0.99, and the gradient using the reflection mode was about twice that of the one using the transmission mode. The non-uniformity error that is produced by a flat-bed scanner with the transmission mode setting could be almost eliminated by converting from the transmission mode to the reflection mode. In light of these findings, the method using a flat-bed scanner with the reflection mode (only using uniform white paper) improved the precision of the measurement for the low absorbed dose range.

  6. Narrow dibaryon resonances

    International Nuclear Information System (INIS)

    Kajdalov, A.B.

    1986-01-01

    Experimental data on np interactions indicating to existence of narrow resonances in pp-system are discussed. Possible theoretical interpretations of these resonances are given. Experimental characteristics of the dibaryon resonances with isospin I=2 are considered

  7. Efficacy and Safety of OnabotulinumtoxinA Treatment of Forehead Lines: A Multicenter, Randomized, Dose-Ranging Controlled Trial.

    Science.gov (United States)

    Solish, Nowell; Rivers, Jason K; Humphrey, Shannon; Muhn, Channy; Somogyi, Chris; Lei, Xiaofang; Bhogal, Meetu; Caulkins, Carrie

    2016-03-01

    Various onabotulinumtoxinA doses are effective in treating forehead lines (FHL), with a trend toward lower doses. To evaluate efficacy and safety of onabotulinumtoxinA dose-ranging treatment of FHL when the frontalis area and glabellar complex are treated together. Adults with moderate-to-severe FHL received onabotulinumtoxinA 40 U (FHL, 20 U; glabellar lines [GL], 20 U), 30 U (FHL, 10 U; GL, 20 U), or placebo. Response was assessed at weeks 1, 2, day 30, and monthly to day 180. Coprimary efficacy end points were investigator- and subject-assessed Facial Wrinkle Scale scores of none or mild (day 30). Patient-reported outcomes, onset/duration of effect, and adverse events (AEs) were evaluated. Responder rates (investigator/subject, respectively) were 40-U group, 91.2%/89.5%; 30-U group, 86.4%/81.4%; placebo, 1.7%/5.1%. OnabotulinumtoxinA resulted in significantly greater responder rates than placebo (p < .001). Adverse events were mild to moderate and similar between groups (most common AEs: nasopharyngitis [4.6%] and headache [4.0%]). Treatment of FHL with onabotulinumtoxinA 40 and 30 U (in frontalis and glabellar complex muscles) was tolerable, effective, and sustained. Both doses significantly reduced FHL severity; however, the 40-U dose demonstrated a trend toward greater sustained benefit and longer duration of effect versus the 30-U dose, with similar AE rates.

  8. Experimental study on dryout point of flow boiling in bilaterally heated narrow annular channel

    International Nuclear Information System (INIS)

    Wu Geping; Wu Aimin; Tian Wenxi; Li Hao; Jia Dounan; Su Guanghui; Qiu Suizheng

    2003-01-01

    This paper presents and experimental study of the dryout point of flow boiling in bilaterally heated narrow annular channel with 1.5 mm and 2 mm annular gap, respectively. The range of pressure is 2.0-4.0 MPa and that of mass flux is 40-80 kg/m 2 ·s. Kutajilagi equation which is adaptable to tubes is used to deal with the experimental data and an empirical equation is obtained. Again this empirical equation is amended, then an empirical equation of the dryout point suitable for narrow annular channel is obtained

  9. Model for diffusion of a narrow beam of charged particles

    International Nuclear Information System (INIS)

    Eisenhauer, C.

    1980-01-01

    A simple analytic expression is presented to describe the three-dimensioned spatial distribution of flux or energy deposition by a narrow beam of charged particles. In this expression distances are expressed in terms of a scaling parameter that is proportional to the mean square scattering angle in a single collision. Finite ranges are expressed in terms of the continuous-slowing-down range. Track-length distributions for one-velocity particles and energy deposition for electrons are discussed. Comparisons with rigorous Monte Carlo calculations show that departures from the analytic expression can be expressed as a slowly varying function of order unity. This function can be used as a basis for interpolation over a wide range of source energies and materials

  10. Narrow line width operation of a 980 nm gain guided tapered diode laser bar

    DEFF Research Database (Denmark)

    Vijayakumar, Deepak; Jensen, Ole Bjarlin; Barrientos-Barria, Jessica

    2011-01-01

    We demonstrate two different schemes for the spectral narrowing of a 12 emitter 980 nm gain guided tapered diode laser bar. In the first scheme, a reflective grating has been used in a Littman Metcalf configuration and the wavelength of the laser emission could be narrowed down from more than 5.......5 nm in the free running mode to 0.04 nm (FWHM) at an operating current of 30 A with an output power of 8 W. The spectrum was found to be tunable within a range of 16 nm. In the second scheme, a volume Bragg grating has been used to narrow the wavelength of the laser bar from over 5 nm to less than 0.......2 nm with an output of 5 W at 20 A. To our knowledge, this is the first time spectral narrowing has been performed on a gain guided tapered diode laser bar. In the Littman Metcalf configuration, the spectral brightness has been increased by 86 times and in the volume Bragg grating cavity the spectral...

  11. Extending the dose range: Probing deep traps in quartz with 3.06 eV photons

    DEFF Research Database (Denmark)

    Jain, Mayank

    2009-01-01

    stimulation. Although, the fast OSL component is measured with similar efficiency by blue and violet lights, the slower OSL components (especially S3) are measured relatively more efficiently with the latter. New insight into the origins of quartz luminescence is presented through a comparison of violet......This article demonstrates that violet (405 nm) stimulated luminescence (VSL) signal from quartz contains contribution from deep traps that are otherwise not accessible with blue light (470 nm). Additionally, it also contains the typical fast and slow components observed with the blue light...... and blue lights stimulation, and thermal stimulations. Finally, it is shown that the deep traps probed through violet light stimulation have potential for increasing the dose measurement/dating range using quartz. The post-blue VSL signal allows easy, precise measurement of dose up to at least 1 kGy in our...

  12. /sup 210/Po in marine organisms: a wide range of natural radiation dose domains

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, F P

    1988-01-01

    Marine biota is able to concentrate /sup 210/Po to high levels, as 10/sup 3/-10/sup 5/ relative to sea water concentration. /sup 210/Po concentrations in mixed zooplankton reaches 34-51 Bq.kg/sup -1/ (fresh wt), special groups such as copepods reaching even higher concentrations /similar to/ 90 Bq.kg/sup -1/, whereas gelatinous zooplankton display /similar to/ 1 Bq.kg/sup -1/. Epipelagic teleosts feeding on plankton displayed the highest concentrations found in fish muscle, 2-21 Bq.kg/sup -1/. Contrasting with this, demersal teleosts and elasmobranchs display lower /sup 210/Po concentrations, in the ranges 0.5-7 Bq.kg/sup -1/ and 0.2-1.7 Bq.kg/sup -1/, respectively. Much higher concentrations can, however, be measured in fish liver, gonad, bone and piloric caecca, and small mesopelagic fish can reach /similar to/ 800 Bq.kg/sup -1/ on a whole-body basis. Due to these /sup 210/Po activity concentrations, dose equivalent rates delivered to biological tissues in marine organisms can vary widely, from 0.4 mSv.y/sup -1/ in gelatinous plankton up to 5.6 x 10/sup 3/ mSv.y/sup -1/ in the gut wall of sardines. It is concluded that in organisms living in the same ocean layer a wide range of internal radiation doses exists and it is essentially sustained by /sup 210/Po food-chain transfer. (author).

  13. Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy

    CERN Document Server

    Peimel-Stuglik, Z

    2001-01-01

    The usefulness of two, easy accessible alanine dosimeters (ALANPOL from IChTJ and foil dosimeter from Gamma Service, Radeberg, Germany) to radiation dose measurement in the range of 0.5-10 kGy, were investigated. In both cases, the result of the test was positive. The foil dosemeter from Gamma Service is recommended for dose distribution measurements in fantoms or products, ALANPOL - for routine measurements. The EPR-alanine method based on the described dosimeters can be successfully used, among others, in the technology of radiation protection of food.

  14. Raman micro-spectroscopy analysis of human lens epithelial cells exposed to a low-dose-range of ionizing radiation

    Science.gov (United States)

    Allen, Christian Harry; Kumar, Achint; Qutob, Sami; Nyiri, Balazs; Chauhan, Vinita; Murugkar, Sangeeta

    2018-01-01

    Recent findings in populations exposed to ionizing radiation (IR) indicate dose-related lens opacification occurs at much lower doses (micro-spectroscopy was used to investigate the effects of varying doses of radiation, ranging from 0.01 Gy to 5 Gy, on human lens epithelial (HLE) cells which were chemically fixed 24 h post-irradiation. Raman spectra were acquired from the nucleus and cytoplasm of the HLE cells. Spectra were collected from points in a 3  ×  3 grid pattern and then averaged. The raw spectra were preprocessed and principal component analysis followed by linear discriminant analysis was used to discriminate between dose and control for 0.25, 0.5, 2, and 5 Gy. Using leave-one-out cross-validation accuracies of greater than 74% were attained for each dose/control combination. The ultra-low doses 0.01 and 0.05 Gy were included in an analysis of band intensities for Raman bands found to be significant in the linear discrimination, and an induced repair model survival curve was fit to a band-difference-ratio plot of this data, suggesting HLE cells undergo a nonlinear response to low-doses of IR. A survival curve was also fit to clonogenic assay data done on the irradiated HLE cells, showing a similar nonlinear response.

  15. Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT.

    Science.gov (United States)

    Shirasaka, Takashi; Funama, Yoshinori; Hayashi, Mutsukazu; Awamoto, Shinichi; Kondo, Masatoshi; Nakamura, Yasuhiko; Hatakenaka, Masamitsu; Honda, Hiroshi

    2012-01-01

    Our purpose in this study was to assess the radiation dose reduction and the actual exposed scan length of over-range areas using a spiral dynamic z-collimator at different beam pitches and detector coverage. Using glass rod dosimeters, we measured the unilateral over-range scan dose between the beginning of the planned scan range and the beginning of the actual exposed scan range. Scanning was performed at detector coverage of 80.0 and 40.0 mm, with and without the spiral dynamic z-collimator. The dose-saving ratio was calculated as the ratio of the unnecessary over-range dose, with and without the spiral dynamic z-collimator. In 80.0 mm detector coverage without the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 108, 120, and 126 mm, corresponding to a beam pitch of 0.60, 0.80, and 0.99, respectively. With the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 48, 66, and 84 mm with a beam pitch of 0.60, 0.80, and 0.99, respectively. The dose-saving ratios with and without the spiral dynamic z-collimator for a beam pitch of 0.60, 0.80, and 0.99 were 35.07, 24.76, and 13.51%, respectively. With 40.0 mm detector coverage, the dose-saving ratios with and without the spiral dynamic z-collimator had the highest value of 27.23% with a low beam pitch of 0.60. The spiral dynamic z-collimator is important for a reduction in the unnecessary over-range dose and makes it possible to reduce the unnecessary dose by means of a lower beam pitch.

  16. Experimental investigation on subcooled boiling heat transfer in a vertical double-face heated narrow annulus

    International Nuclear Information System (INIS)

    Yan Mingyu; Qiu Suizheng; Jia Dounan

    2005-01-01

    Experimental investigation on the subcooled boiling heat transfer was carried out in a vertical up-flow double narrow annulus with 1.5 mm gap. The working fluid is deionized water. The ranges of parameters as follows: pressure 0.84-6.09 MPa, mass flux 41.9-300.2 kg/(m 2 ·s), heat flux 2.61-114.41kW/m 2 . An empiric correlation used to predict the heat transfer of subcooled boiling in narrow annulus is induced from the experimental data. (author)

  17. The effect on lower spine muscle activation of walking on a narrow beam in virtual reality

    OpenAIRE

    Antley, Angus; Slater, Mel

    2011-01-01

    To what extent do people behave in immersive virtual environments as they would in similar situations in a physical environment? There are many ways to address this question, ranging from questionnaires, behavioral studies, and the use of physiological measures. Here, we compare the onsets of muscle activity using surface electromyography (EMG) while participants were walking under three different conditions: on a normal floor surface, on a narrow ribbon along the floor, and on a narrow platf...

  18. Linezolid in the treatment of drug-resistant tuberculosis: the challenge of its narrow therapeutic index.

    Science.gov (United States)

    Wasserman, Sean; Meintjes, Graeme; Maartens, Gary

    2016-10-01

    Linezolid is an oxazolidinone with potent activity against M tuberculosis, and improves culture conversion and cure rates when added to treatment regimens for drug resistant tuberculosis. However, linezolid has a narrow therapeutic window, and the optimal dosing strategy that minimizes the substantial toxicity associated with linezolid's prolonged use in tuberculosis treatment has not been determined, limiting the potential impact of this anti-mycobacterial agent. This paper aims to review and summarize the current knowledge on linezolid for the treatment of drug-resistant tuberculosis. The focus is on the pharmacokinetic-pharmacodynamic determinants of linezolid's efficacy and toxicity in tuberculosis, and how this relates to defining an optimal dose. Mechanisms of linezolid toxicity and resistance, and the potential role of therapeutic drug monitoring are also covered. Expert commentary: Prospective pharmacokinetic-pharmacodynamic studies are required to define optimal therapeutic targets and to inform improved linezolid dosing strategies for drug-resistant tuberculosis.

  19. Evolution of deformation velocity in narrowing for Zircaloy 2

    Energy Technology Data Exchange (ETDEWEB)

    Cetlin, P R [Minas Gerais Univ., Belo Horizonte (Brazil). Dept. de Engenharia Metalurgica; Okuda, M Y [Goias Univ., Goiania (Brazil). Inst. de Matematica e Fisica

    1980-09-01

    Some studies on the deformation instability in strain shows that the differences in this instability may lead to localized narrowing or elongated narrowing, for Zircaloy-2. The variation of velocity deformation with the narrowing evolution is expected to be different for these two cases. The mentioned variation is discussed, a great difference in behavior having been observed for the case of localized narrowing.

  20. Quantifying the spatial and temporal variation in dose from external exposure to radiation: a new tool for use on free-ranging wildlife

    International Nuclear Information System (INIS)

    Hinton, Thomas G.; Byrne, Michael E.; Webster, Sarah; Beasley, James C.

    2015-01-01

    Inadequate dosimetry is often the fundamental problem in much of the controversial research dealing with radiation effects on free-ranging wildlife. Such research is difficult because of the need to measure dose from several potential pathways of exposure (i.e., internal contamination, external irradiation, and inhalation). Difficulties in quantifying external exposures can contribute significantly to the uncertainties of dose-effect relationships. Quantifying an animal's external exposure due to spatial–temporal use of habitats that can vary by orders of magnitude in radiation levels is particularly challenging. Historically, wildlife dosimetry studies have largely ignored or been unable to accurately quantify variability in external dose because of technological limitations. The difficulties of quantifying the temporal–spatial aspects of external irradiation prompted us to develop a new dosimetry instrument for field research. We merged two existing technologies [Global Positioning Systems (GPS) and electronic dosimeters] to accommodate the restrictive conditions of having a combined unit small enough to be unobtrusively worn on the neck of a free-ranging animal, and sufficiently robust to withstand harsh environmental conditions. The GPS–dosimeter quantifies the spatial and temporal variation in external dose as wildlife traverse radioactively contaminated habitats and sends, via satellites, an animal's location and short term integrated dose to the researcher at a user-defined interval. Herein we describe: (1) the GPS–dosimeters; (2) tests to compare their uniformity of response to external irradiation under laboratory conditions; (3) field tests of their durability when worn on wildlife under natural conditions; and (4) a field application of the new technology at a radioactively contaminated site. Use of coupled GPS–dosimetry will allow, for the first time, researchers to better understand the relationship of animals to their contaminated

  1. Narrow Networks on the Individual Marketplace in 2017.

    Science.gov (United States)

    Polski, Daniel; Weiner, Janet; Zhang, Yuehan

    2017-09-01

    This Issue Brief describes the breadth of physician networks on the ACA marketplaces in 2017. We find that the overall rate of narrow networks is 21%, which is a decline since 2014 (31%) and 2016 (25%). Narrow networks are concentrated in plans sold on state-based marketplaces, at 42%, compared to 10% of plans on federally-facilitated marketplaces. Issuers that have traditionally offered Medicaid coverage have the highest prevalence of narrow network plans at 36%, with regional/local plans and provider-based plans close behind at 27% and 30%. We also find large differences in narrow networks by state and by plan type.

  2. Ultra narrow bore thick film capillaries for microcolumn separations. Part 1. GC experiments

    NARCIS (Netherlands)

    Steenackers, D.; Sandra, P.J.F.; Sandra, P.; Devos, G.

    1993-01-01

    Ultra narrow bore (50 mum 1.0.) fused silica columns were statically coated with apolar stationary phases to obtain beta values ranging from 6.25 to 50 (filmthickness 2 to 0.25 mum). Performance of the 1 and 2 mum columns in Capillary Gas Chromatography (CGC) is highlighted.

  3. Depletion of eIF4G from yeast cells narrows the range of translational efficiencies genome-wide

    Directory of Open Access Journals (Sweden)

    Hinnebusch Alan G

    2011-01-01

    Full Text Available Abstract Background Eukaryotic translation initiation factor 4G (eIF4G is thought to influence the translational efficiencies of cellular mRNAs by its roles in forming an eIF4F-mRNA-PABP mRNP that is competent for attachment of the 43S preinitiation complex, and in scanning through structured 5' UTR sequences. We have tested this hypothesis by determining the effects of genetically depleting eIF4G from yeast cells on global translational efficiencies (TEs, using gene expression microarrays to measure the abundance of mRNA in polysomes relative to total mRNA for ~5900 genes. Results Although depletion of eIF4G is lethal and reduces protein synthesis by ~75%, it had small effects (less than a factor of 1.5 on the relative TE of most genes. Within these limits, however, depleting eIF4G narrowed the range of translational efficiencies genome-wide, with mRNAs of better than average TE being translated relatively worse, and mRNAs with lower than average TE being translated relatively better. Surprisingly, the fraction of mRNAs most dependent on eIF4G display an average 5' UTR length at or below the mean for all yeast genes. Conclusions This finding suggests that eIF4G is more critical for ribosome attachment to mRNAs than for scanning long, structured 5' UTRs. Our results also indicate that eIF4G, and the closed-loop mRNP it assembles with the m7 G cap- and poly(A-binding factors (eIF4E and PABP, is not essential for translation of most (if not all mRNAs but enhances the differentiation of translational efficiencies genome-wide.

  4. Narrow thermal hysteresis of NiTi shape memory alloy thin films with submicrometer thickness

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Huilong; Hamilton, Reginald F., E-mail: rfhamilton@psu.edu; Horn, Mark W. [Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, Pennsylvania 16802 (United States)

    2016-09-15

    NiTi shape memory alloy (SMA) thin films were fabricated using biased target ion beam deposition (BTIBD), which is a new technique for fabricating submicrometer-thick SMA thin films, and the capacity to exhibit shape memory behavior was investigated. The thermally induced shape memory effect (SME) was studied using the wafer curvature method to report the stress-temperature response. The films exhibited the SME in a temperature range above room temperature and a narrow thermal hysteresis with respect to previous reports. To confirm the underlying phase transformation, in situ x-ray diffraction was carried out in the corresponding phase transformation temperature range. The B2 to R-phase martensitic transformation occurs, and the R-phase transformation is stable with respect to the expected conversion to the B19′ martensite phase. The narrow hysteresis and stable R-phase are rationalized in terms of the unique properties of the BTIBD technique.

  5. An analytical model for predicting dryout point in bilaterally heated vertical narrow annuli

    International Nuclear Information System (INIS)

    Aye Myint; Tian Wenxi; Jia Dounan; Li Zhihui, Li Hao

    2005-02-01

    Based on the the droplet-diffusion model by Kirillov and Smogalev (1969, 1972), a new analytical model of dryout point prediction in the steam-water flow for bilaterally and uniformly heated narrow annular gap was developed. Comparison of the present model predictions with experimental results indicated that a good agreement in accuracy for the experimental parametric range (pressure from 0.8 to 3.5 MPa, mass flux of 60.39 to 135.6 kg· -2 ·s -1 and the heat flus of 50 kW·m -2 . Prediction of dryout point was experimentally investigated with deionized water upflowing through narrow annular channel with 1.0 mm and 1.5 mm gap heated by AC power supply. (author)

  6. H-tailored surface conductivity in narrow band gap In(AsN)

    Energy Technology Data Exchange (ETDEWEB)

    Velichko, A. V., E-mail: amalia.patane@nottingham.ac.uk, E-mail: anton.velychko@nottingham.ac.uk; Patanè, A., E-mail: amalia.patane@nottingham.ac.uk, E-mail: anton.velychko@nottingham.ac.uk; Makarovsky, O. [School of Physics and Astronomy, The University of Nottingham, Nottingham NG7 2RD (United Kingdom); Capizzi, M.; Polimeni, A. [Dipartimento di Fisica, Sapienza Università di Roma, Piazzale A. Moro 2, 00185 Roma (Italy); Sandall, I. C.; Tan, C. H. [Department of Electronic and Electrical Engineering, The University of Sheffield, Sheffield S1 3JD (United Kingdom); Giubertoni, D. [Center for Materials and Microsystems—Fondazione Bruno Kessler, via Sommarive 18, 38123 Povo, Trento (Italy); Krier, A.; Zhuang, Q. [Physics Department, Lancaster University, Lancaster LA1 4YB (United Kingdom)

    2015-01-12

    We show that the n-type conductivity of the narrow band gap In(AsN) alloy can be increased within a thin (∼100 nm) channel below the surface by the controlled incorporation of H-atoms. This channel has a large electron sheet density of ∼10{sup 18 }m{sup −2} and a high electron mobility (μ > 0.1 m{sup 2}V{sup −1}s{sup −1} at low and room temperature). For a fixed dose of impinging H-atoms, its width decreases with the increase in concentration of N-atoms that act as H-traps thus forming N-H donor complexes near the surface.

  7. Narrowing beam-walking is a clinically feasible approach for assessing balance ability in lower-limb prosthesis users.

    Science.gov (United States)

    Sawers, Andrew; Hafner, Brian J

    2018-05-08

    Challenging clinical balance tests are needed to expose balance deficits in lower-limb prost-hesis users. This study examined whether narrowing beam-walking could overcome conceptual and practical limitations identified in fixed-width beam-walking. Cross-sectional. Unilateral lower-limb prosthesis users. Participants walked 10 times along a low, narrowing beam. Performance was quantified using the normalized distance walked. Heuristic rules were applied to determine whether the narrowing beam task was "too easy," "too hard," or "appropriately challenging" for each participant. Linear regression and Bland-Altman plots were used to determine whether combinations of the first 5 trials could predict participants' stable beam-walking performance. Forty unilateral lower-limb prosthesis users participated. Narrowing beam-walking was appropriately challenging for 98% of participants. Performance stabilized for 93% of participants within 5 trials, while 62% were stable across all trials. The mean of trials 3-5 accurately predicted stable performance. A clinical narrowing beam-walking test is likely to challenge a range of lower-limb prosthesis users, have minimal administrative burden, and exhibit no floor or ceiling effects. Narrowing beam-walking is therefore a clinically viable method to evaluate lower-limb prosthesis users' balance ability, but requires psychometric testing before it is used to assess fall risk.

  8. Low doses of ionizing radiation and hydrogen peroxide stimulate plant growth

    International Nuclear Information System (INIS)

    Korystov, Y.; Narimanov, A.

    1997-01-01

    The present study shows that low-dose oxidative stress induced by ionizing radiation (10-20 cGy) and hydrogen peroxide (1-100 pmol per litre) stimulates germination of seeds and growth of sprouts and roots. The growth of seedlings can be stimulated by treatment of seeds as well as seedlings but in the latter case it needs lower doses. The stimulation effect is observed in a narrow dose interval which is the same for the plant species studied: barley, wheat, pea, maize and melon

  9. Ocular Biometrics of Myopic Eyes With Narrow Angles.

    Science.gov (United States)

    Chong, Gabriel T; Wen, Joanne C; Su, Daniel Hsien-Wen; Stinnett, Sandra; Asrani, Sanjay

    2016-02-01

    The purpose of this study was to compare the ocular biometrics between myopic patients with and without narrow angles. Patients with a stable myopic refraction (myopia worse than -1.00 D spherical equivalent) were prospectively recruited. Angle status was assessed using gonioscopy and biometric measurements were performed using an anterior segment optical coherence tomography and an IOLMaster. A total of 29 patients (58 eyes) were enrolled with 13 patients (26 eyes) classified as having narrow angles and 16 patients (32 eyes) classified as having open angles. Baseline demographics of age, sex, and ethnicity did not differ significantly between the 2 groups. The patients with narrow angles were on average older than those with open angles but the difference did not reach statistical significance (P=0.12). The central anterior chamber depth was significantly less in the eyes with narrow angles (P=0.05). However, the average lens thickness, although greater in the eyes with narrow angles, did not reach statistical significance (P=0.10). Refractive error, axial lengths, and iris thicknesses did not differ significantly between the 2 groups (P=0.32, 0.47, 0.15). Narrow angles can occur in myopic eyes. Routine gonioscopy is therefore recommended for all patients regardless of refractive error.

  10. Intramyocardial arterial narrowing in dogs with subaortic stenosis.

    Science.gov (United States)

    Falk, T; Jönsson, L; Pedersen, H D

    2004-09-01

    Earlier studies have described intramyocardial arterial narrowing based on hyperplasia and hypertrophy of the vessel wall in dogs with subaortic stenosis (SAS). In theory, such changes might increase the risk of sudden death, as they seem to do in heart disease in other species. This retrospective pathological study describes and quantifies intramyocardial arterial narrowing in 44 dogs with naturally occurring SAS and in eight control dogs. The majority of the dogs with SAS died suddenly (n=27); nine had died or been euthanased with signs of heart failure and eight were euthanased without clinical signs. Dogs with SAS had significantly narrower intramyocardial arteries (Pdogs. Male dogs and those with more severe hypertrophy had more vessel narrowing (P=0.02 and P=0.02, respectively), whereas dogs with dilated hearts had slightly less pronounced arterial thickening (P=0.01). Arterial narrowing was not related to age, but fibrosis increased with age (P=0.047). Dogs that died suddenly did not have a greater number of arterial changes than other dogs with SAS. This study suggests that most dogs with SAS have intramyocardial arterial narrowing and that the risk of dying suddenly is not significantly related to the overall degree of vessel obliteration.

  11. Relativistic jets in narrow-line Seyfert 1 galaxies. New discoveries and open questions

    Directory of Open Access Journals (Sweden)

    D’Ammando F.

    2013-12-01

    Full Text Available Before the launch of the Fermi satellite only two classes of AGNs were known to produce relativistic jets and thus emit up to the γ-ray energy range: blazars and radio galaxies, both hosted in giant elliptical galaxies. The first four years of observations by the Large Area Telescope on board Fermi confirmed that these two are the most numerous classes of identified sources in the extragalactic γ-ray sky, but the discovery of γ-ray emission from 5 radio-loud narrow-line Seyfert 1 galaxies revealed the presence of a possible emerging third class of AGNs with relativistic jets. Considering that narrow-line Seyfert 1 galaxies seem to be typically hosted in spiral galaxy, this finding poses intriguing questions about the nature of these objects, the onset of production of relativistic jets, and the cosmological evolution of radio-loud AGN. Here, we discuss the radio-to-γ-rays properties of the γ-ray emitting narrow-line Seyfert 1 galaxies, also in comparison with the blazar scenario.

  12. Astigmatism-free high-brightness 1060 nm edge-emitting lasers with narrow circular beam profile.

    Science.gov (United States)

    Miah, Md Jarez; Kalosha, Vladimir P; Bimberg, Dieter; Pohl, Johannes; Weyers, Markus

    2016-12-26

    1060 nm high-brightness vertical broad-area edge-emitting lasers providing anastigmatic high optical power into a narrow circular beam profile are demonstrated. Ridge-waveguide (RW) lasers yield record 2.2 W single-transverse mode power in the 1060-nm wavelength range under continuous-wave (cw) operation at room temperature with excellent beam quality factor M2 ≤ 2. Independent of operating current the astigmatism is only 2.5 µm. 3 mm long broad-area (BA) lasers produce a θvert as narrow as 9° full width at half maximum, which agrees well with our simulation results, being insensitive to drive current. 5 mm long BA lasers deliver highest ever reported cw 12 W multimode output power among lasers showing θvert <10° in the 1060-nm wavelength range. The emitted laser beams from both RW and BA lasers show a perfect circular shape with ≤10° divergence angle at record 2.1 W and 4.2 W cw-mode output power, respectively.

  13. Highly Tunable Narrow Bandpass MEMS Filter

    KAUST Repository

    Hafiz, Md Abdullah Al

    2017-07-07

    We demonstrate a proof-of-concept highly tunable narrow bandpass filter based on electrothermally and electrostatically actuated microelectromechanical-system (MEMS) resonators. The device consists of two mechanically uncoupled clamped-clamped arch resonators, designed such that their resonance frequencies are independently tuned to obtain the desired narrow passband. Through the electrothermal and electrostatic actuation, the stiffness of the structures is highly tunable. We experimentally demonstrate significant percentage tuning (~125%) of the filter center frequency by varying the applied electrothermal voltages to the resonating structures, while maintaining a narrow passband of 550 ± 50 Hz, a stopband rejection of >17 dB, and a passband ripple ≤ 2.5 dB. An analytical model based on the Euler-Bernoulli beam theory is used to confirm the behavior of the filter, and the origin of the high tunability using electrothermal actuation is discussed.

  14. Paradigm shift in LUNG SBRT dose calculation associated with Heterogeneity correction

    International Nuclear Information System (INIS)

    Zucca Aparicio, D.; Perez Moreno, J. M.; Fernandez Leton, P.; Garcia Ruiz-Zorrilla, J.; Pinto Monedero, M.; Marti Asensjo, J.; Alonso Iracheta, L.

    2015-01-01

    Treatment of lung injury SBRT requires great dosimetric accuracy, the increasing clinical importance of dose calculation heterogeneities introducing algorithms that adequately model the transport of particles narrow beams in media of low density, as with Monte Carlo calculation. (Author)

  15. Investigations on the influence of aminopropyl-aminoethyl-phosphorothioic acid on the radio-iron utilization after a whole-body irradiation of mice in the sublethal dose range

    International Nuclear Information System (INIS)

    Moenig, H.; Seiter, I.; Kofler, E.

    1975-01-01

    The effectiveness of the thiophosphate compound WR 2721 was investigated with regard to the radiosensitivity of X-irradiated female mice in the sublethal dose range of 50 to 150 R using the radioiron test ( 59 Fe). An increase of the radioresistance with regard to the radioiron uptake in young erythrocyte populations was obtained only beyond radiation doses of 75 R. In lower dose ranges the animals treated with thiophoshate became even more radiosensitive. At dose values of 100 R and 150 R dose reduction factors (DRF) of 1.3 and 1.5 respectively were obtained. These factors are considerably smaller than the DRF-values found for the survival rate at LDsub(50/30). A possible mechanism for this result may be due to the different dephosphorylation rate of the thiophosphate in various tissues, as described in literature. (orig.) [de

  16. Cavities at the Si projected range by high dose and energy Si ion implantation in Si

    International Nuclear Information System (INIS)

    Canino, M.; Regula, G.; Lancin, M.; Xu, M.; Pichaud, B.; Ntzoenzok, E.; Barthe, M.F.

    2009-01-01

    Two series of n-type Si samples α and β are implanted with Si ions at high dose (1 x 10 16 ) and high energies, 0.3 and 1.0 MeV, respectively. Both sort of samples are then implanted with 5 x 10 16 He cm -2 (at 10 or 50 keV) and eventually with B atoms. Some of the samples are annealed at temperatures ranging from 800 to 1000 deg. C to allow the thermal growth of He-cavities, located between sample surface and the projected range (R p ) of Si. After the triple ion implantation, which corresponds to defect engineering, samples were characterized by cross-section transmission electron microscopy (XTEM). Voids (or bubbles) are observed not only at the R p (He) on all annealed samples, but also at the R p (Si) on β samples implanted with He at 50 keV. The samples are also studied by positron annihilation spectroscopy (PAS) and the spectra confirm that as-implanted samples contain di-vacancies and that the annealed ones, even at high temperature have bigger open volumes, which are assumed to be the same voids observed by XTEM. It is demonstrated that a sole Si implantation at high energy and dose is efficient to create cavities which are thermally stable up to 1000 deg. C only in the presence of He.

  17. Winter Precipitation Efficiency of Mountain Ranges in the Colorado Rockies Under Climate Change

    Science.gov (United States)

    Eidhammer, Trude; Grubišić, Vanda; Rasmussen, Roy; Ikdea, Kyoko

    2018-03-01

    Orographic precipitation depends on the environmental conditions and the barrier shape. In this study we examine the sensitivity of the precipitation efficiency (i.e., drying ratio (DR)), defined as the ratio of precipitation to incoming water flux, to mountain shape, temperature, stability, and horizontal velocity of the incoming air mass. Furthermore, we explore how the DR of Colorado mountain ranges might change under warmer and moister conditions in the future. For given environmental conditions, we find the DR to be primarily dependent on the upwind slope for mountain ranges wider than about 70 km and on both the slope and width for narrower ranges. Temperature is found to exert an influence on the DR for all Colorado mountain ranges, with DR decreasing with increasing temperature, under both the current and future climate conditions. The decrease of DR with temperature under warmer climate was found to be stronger for wider mountains than the narrower ones. We attribute this asymmetry to the sensitivity of DR to reduced horizontal velocity under warmer conditions. Specifically, while DR for wider mountains shows no sensitivity to changes in horizontal velocity, the DR for narrow ranges increases as the horizontal velocity decreases and more time is provided for precipitation to form. Thus, for narrower ranges, the horizontal velocity appears to offset the temperature effect slightly. The percentagewise decrease of DR for all examined mountain ranges is about 4%K-1. In comparison, the increase in precipitation is about 6%K-1 while the vapor flux increase is about 9%K-1.

  18. Narrowing beam-walking is a clinically feasible approach for assessing balance ability in lower-limb prosthesis users

    Directory of Open Access Journals (Sweden)

    Andrew Sawers

    2018-03-01

    Full Text Available Objective: Challenging clinical balance tests are needed to expose balance deficits in lower-limb prost-hesis users. This study examined whether narrowing beam-walking could overcome conceptual and practical limitations identified in fixed-width beam-walking. Design: Cross-sectional. Participants: Unilateral lower-limb prosthesis users. Methods: Participants walked 10 times along a low, narrowing beam. Performance was quantified using the normalized distance walked. Heuristic rules were applied to determine whether the narrowing beam task was “too easy,” “too hard,” or “appropriately challenging” for each participant. Linear regression and Bland-Altman plots were used to determine whether combinations of the first 5 trials could predict participants’ stable beam-walking performance. Results: Forty unilateral lower-limb prosthesis users participated. Narrowing beam-walking was appropriately challenging for 98% of participants. Performance stabilized for 93% of participants within 5 trials, while 62% were stable across all trials. The mean of trials 3–5 accurately predicted stable performance. Conclusion: A clinical narrowing beam-walking test is likely to challenge a range of lower-limb prosthesis users, have minimal administrative burden, and exhibit no floor or ceiling effects. Narrowing beam-walking is therefore a clinically viable method to evaluate lower-limb prosthesis users’ balance ability, but requires psychometric testing before it is used to assess fall risk.

  19. Development of direct reading dosimeters for the dose 0-3 mSv and 0-5 mSv ranges for personnel monitoring

    International Nuclear Information System (INIS)

    Gaikwad, P.V.; Shirkar, Y.B.; Patil, A.S.; Madgaonkar, P.P.; Kale, K.L.; Guhagarkar, H.V.; Gandhi, D.P.; Gupta, S.K.; Kothiyal, G.P.; Sahni, V.C.

    1998-01-01

    Direct reading dosimeters (DRDs) are widely used to measure cumulative dose received by personnel working at nuclear reactor sites or in other environment having x- and gamma rays. A DRD operates on the principle of gold leaf electroscope, and is a small, rugged, hermetically sealed, self reading type device easily carried by an individual in his pocket. The development of dosimeters suitable for the dose ranges 0-3 mSv and 0-5 mSv is reported

  20. The mechanical behavior and reliability prediction of the HTR graphite component at various temperature and neutron dose ranges

    International Nuclear Information System (INIS)

    Fang, Xiang; Yu, Suyuan; Wang, Haitao; Li, Chenfeng

    2014-01-01

    Highlights: • The mechanical behavior of graphite component in HTRs under high temperature and neutron irradiation conditions is simulated. • The computational process of mechanical analysis is introduced. • Deformation, stresses and failure probability of the graphite component are obtained and discussed. • Various temperature and neutron dose ranges are selected in order to investigate the effect of in-core conditions on the results. - Abstract: In a pebble-bed high temperature gas-cooled reactor (HTR), nuclear graphite serves as the main structural material of the side reflectors. The reactor core is made up of a large number of graphite bricks. In the normal operation case of the reactor, the maximum temperature of the helium coolant commonly reaches about 750 °C. After around 30 years’ full power operation, the peak value of in-core fast neutron cumulative dose reaches to 1 × 10 22 n cm −2 (EDN). Such high temperature and neutron irradiation strongly impact the behavior of graphite component, causing obvious deformation. The temperature and neutron dose are unevenly distributed inside a graphite brick, resulting in stress concentrations. The deformation and stress concentration can both greatly affect safety and reliability of the graphite component. In addition, most of the graphite properties (such as Young's modulus and coefficient of thermal expansion) change remarkably under high temperature and neutron irradiations. The irradiation-induced creep also plays a very important role during the whole process, and provides a significant impact on the stress accumulation. In order to simulate the behavior of graphite component under various in-core conditions, all of the above factors must be considered carefully. In this paper, the deformation, stress distribution and failure probability of a side graphite component are studied at various temperature points and neutron dose levels. 400 °C, 500 °C, 600 °C and 750 °C are selected as the

  1. TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

    International Nuclear Information System (INIS)

    Young, S; Lo, P; Hoffman, J; Wahi-Anwar, M; Brown, M; McNitt-Gray, M; Noo, F

    2016-01-01

    Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modules in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT_wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range

  2. TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

    Energy Technology Data Exchange (ETDEWEB)

    Young, S; Lo, P; Hoffman, J; Wahi-Anwar, M; Brown, M; McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States); Noo, F [University of Utah, Salt Lake City, UT (United States)

    2016-06-15

    Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modules in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT-wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range

  3. The effect of narrow provider networks on health care use.

    Science.gov (United States)

    Atwood, Alicia; Lo Sasso, Anthony T

    2016-12-01

    Network design is an often overlooked aspect of health insurance contracts. Recent policy factors have resulted in narrower provider networks. We provide plausibly causal evidence on the effect of narrow network plans offered by a large national health insurance carrier in a major metropolitan market. Our econometric design exploits the fact that some firms offer a narrow network plan to their employees and some do not. Our results show that narrow network health plans lead to reductions in health care utilization and spending. We find evidence that narrow networks save money by selecting lower cost providers into the network. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Dose-response relationship for life-shortening and carcinogenesis in mice irradiated at day 7 postnatal age with dose range below 1 Gy of gamma rays

    International Nuclear Information System (INIS)

    Sasaki, Shunsaku; Fukuda, Nobuo

    2006-01-01

    This study was designed to elucidate the dose-response relationships for life-shortening and tumorigenic effect in the dose range below 1 Gy of gamma rays delivered during the infant period. Female B6C3F 1 mice were irradiated with 0.10, 0.48 or 0.95 Gy at 7 days of age. All irradiated mice were allowed to live out their entire life span together with a simultaneously ongoing control group under a specific pathogen-free condition. Shortening of the mean life span was 1.58% in mice irradiated with 0.10 Gy, which was statistically significant. The coefficient of the linear dose-response relationship for life-shortening was 11.21% Gy -1 . The attributable death fraction for all causes of death in 0.10 Gy group reached 0.092. The excess relative risk for death rate from all causes was 0.102 in the group irradiated with 0.10 Gy. The coefficient of the linear dose-response relationship of the excess relative risk for death rate from all causes was 1.30 Gy -1 . The mean number of types of solid tumors at the time of death in mice irradiated with 0.10 Gy was distinctly larger than that in the control group. The excess relative risk for death rate from solid tumors was 0.45 in mice irradiated with 0.10 Gy. The coefficient of the linear dose-response relationship of excess relative risk for death rate from solid tumors was 4.52 Gy -1 . Increase in incidences of the pituitary, ovarian and adrenal tumors was observed in mice irradiated with 0.10 Gy. The results of the present study showed that infant mice are susceptible to solid tumor induction, especially of the endocrine organs. (author)

  5. Narrowing of the middle cerebral artery: artificial intelligence methods and comparison of transcranial color coded duplex sonography with conventional TCD.

    Science.gov (United States)

    Swiercz, Miroslaw; Swiat, Maciej; Pawlak, Mikolaj; Weigele, John; Tarasewicz, Roman; Sobolewski, Andrzej; Hurst, Robert W; Mariak, Zenon D; Melhem, Elias R; Krejza, Jaroslaw

    2010-01-01

    The goal of the study was to compare performances of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of the middle cerebral artery (MCA) narrowing in the same population of patients using statistical and nonstatistical intelligent models for data analysis. We prospectively collected data from 179 consecutive routine digital subtraction angiography (DSA) procedures performed in 111 patients (mean age 54.17+/-14.4 years; 59 women, 52 men) who underwent TCD and TCCS examinations simultaneously. Each patient was examined independently using both ultrasound techniques, 267 M1 segments of MCA were assessed and narrowings were classified as 50% lumen reduction. Diagnostic performance was estimated by two statistical and two artificial neural networks (ANN) classification methods. Separate models were constructed for the TCD and TCCS sonographic data, as well as for detection of "any narrowing" and "severe narrowing" of the MCA. Input for each classifier consisted of the peak-systolic, mean and end-diastolic velocities measured with each sonographic method; the output was MCA narrowing. Arterial narrowings less or equal 50% of lumen reduction were found in 55 and >50% narrowings in 26 out of 267 arteries, as indicated by DSA. In the category of "any narrowing" the rate of correct assignment by all models was 82% to 83% for TCCS and 79% to 81% for TCD. In the diagnosis of >50% narrowing the overall classification accuracy remained in the range of 89% to 90% for TCCS data and 90% to 91% for TCD data. For the diagnosis of any narrowing, the sensitivity of the TCCS was significantly higher than that of the TCD, while for diagnosis of >50% MCA narrowing, sensitivity of the TCCS was similar to sensitivity of the TCD. Our study showed that TCCS outperforms conventional TCD in detection of diagnosis of >50% MCA narrowing. (E-mail: jaroslaw.krejza@uphs.upenn.edu).

  6. Narrow Field of View Zenith Radiometer (NFOV) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, C; Marshak, A; Hodges, G; Barnard, JC; Schmelzer, J

    2008-11-01

    The two-channel narrow field-of-view radiometer (NFOV2) is a ground-based radiometer that looks straight up and measures radiance directly above the instrument at wavelengths of 673 and 870 nm. The field-of-view of the instrument is 1.2 degrees, and the sampling time resolution is one second. Measurements of the NFOV2 have been used to retrieve optical properties for overhead clouds that range from patchy to overcast. With a one-second sampling rate of the NFOV2, faster than almost any other ARM Climate Research Facility (ACRF) instrument, we are able, for the first time, to capture changes in cloud optical properties at the natural time scale of cloud evolution.

  7. Narrow Quasar Absorption Lines and the History of the Universe

    Science.gov (United States)

    Liebscher, Dierck-Ekkehard

    In order to get an estimation of the parameters of the cosmological model the statistics of narrow absorption lines in quasar spectra is evaluated. To this end a phenomenological model of the evolution of the corresponding absorbers in density, size, number and dimension is presented and compared with the observed evolution in the spectral density of the lines and their column density seen in the equivalent width. In spite of the wide range of possible models, the Einstein-deSitter model is shown to be unlikely because of the implied fast evolution in mass.

  8. Dose assessment in pediatric computerized tomography; Avaliacao de doses em tomografia computadorizada pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Vilarinho, Luisa Maria Auredine Lima

    2004-07-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI{sub w} obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI{sub w} values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI{sub w} . (author)

  9. Correlates of Narrow Bracketing

    DEFF Research Database (Denmark)

    Koch, Alexander; Nafziger, Julia

    We examine whether different phenomena of narrow bracketing can be traced back to some common characteristic and whether and how different phenomena are related. We find that making dominated lottery choices or ignoring the endowment when making risky choices are related phenomena and are both as...

  10. Nonlinear dynamic range transformation in visual communication channels.

    Science.gov (United States)

    Alter-Gartenberg, R

    1996-01-01

    The article evaluates nonlinear dynamic range transformation in the context of the end-to-end continuous-input/discrete processing/continuous-display imaging process. Dynamic range transformation is required when we have the following: (i) the wide dynamic range encountered in nature is compressed into the relatively narrow dynamic range of the display, particularly for spatially varying irradiance (e.g., shadow); (ii) coarse quantization is expanded to the wider dynamic range of the display; and (iii) nonlinear tone scale transformation compensates for the correction in the camera amplifier.

  11. An enhanced narrow-band imaging method for the microvessel detection

    Science.gov (United States)

    Yu, Feng; Song, Enmin; Liu, Hong; Wan, Youming; Zhu, Jun; Hung, Chih-Cheng

    2018-02-01

    A medical endoscope system combined with the narrow-band imaging (NBI), has been shown to be a superior diagnostic tool for early cancer detection. The NBI can reveal the morphologic changes of microvessels in the superficial cancer. In order to improve the conspicuousness of microvessel texture, we propose an enhanced NBI method to improve the conspicuousness of endoscopic images. To obtain the more conspicuous narrow-band images, we use the edge operator to extract the edge information of the narrow-band blue and green images, and give a weight to the extracted edges. Then, the weighted edges are fused with the narrow-band blue and green images. Finally, the displayed endoscopic images are reconstructed with the enhanced narrow-band images. In addition, we evaluate the performance of enhanced narrow-band images with different edge operators. Experimental results indicate that the Sobel and Canny operators achieve the best performance of all. Compared with traditional NBI method of Olympus company, our proposed method has more conspicuous texture of microvessel.

  12. Dose and dose rate monitor

    International Nuclear Information System (INIS)

    Novakova, O.; Ryba, J.; Slezak, V.; Svobodova, B.; Viererbl, L.

    1984-10-01

    The methods are discussea of measuring dose rate or dose using a scintillation counte. A plastic scintillator based on polystyrene with PBD and POPOP activators and coated with ZnS(Ag) was chosen for the projected monitor. The scintillators were cylindrical and spherical in shape and of different sizes; black polypropylene tubes were chosen as the best case for the probs. For the counter with different plastic scintillators, the statistical error 2σ for natural background was determined. For determining the suitable thickness of the ZnS(Ag) layer the energy dependence of the counter was measured. Radioisotopes 137 Cs, 241 Am and 109 Cd were chosen as radiation sources. The best suited ZnS(Ag) thickness was found to be 0.5 μm. Experiments were carried out to determine the directional dependence of the detector response and the signal to noise ratio. The temperature dependence of the detector response and its compensation were studied, as were the time stability and fatigue manifestations of the photomultiplier. The design of a laboratory prototype of a dose rate and dose monitor is described. Block diagrams are given of the various functional parts of the instrument. The designed instrument is easiiy portable, battery powered, measures dose rates from natural background in the range of five orders, i.e., 10 -2 to 10 3 nGy/s, and allows to determine a dose of up to 10 mGy. Accouracy of measurement in the energy range of 50 keV to 1 MeV is better than +-20%. (E.S.)

  13. A high stability wavelength-tunable narrow-linewidth and single-polarization erbium-doped fiber laser using a compound-cavity structure

    International Nuclear Information System (INIS)

    Feng, Ting; Yan, Fengping; Peng, Wanjing; Liu, Shuo; Tan, Siyu; Liang, Xiao; Wen, Xiaodong

    2014-01-01

    A high stability wavelength-tunable narrow-linewidth and single-polarization erbium-doped fiber laser using a compound-cavity structure is proposed and demonstrated experimentally. The compound-cavity is composed of a main-linear-cavity and a subring-cavity. Using a pump power of 150 mW, the optical signal to noise ratio of the laser output is as high as ∼67 dB; the wavelength and output power fluctuation are 0.7 pm and 0.07 dBm respectively in an experimental period of 1 h; the linewidth of the laser output is as narrow as 650 Hz; the degree of polarization of the laser output is stable at a value of 100.8% in 15 min and the polarization extinction ratio is as high as 30.57 dB; the wavelength-tunable range is as wide as ∼8.1 nm. The proposed fiber laser can be used in areas where high stability, narrow-linewidth, single-polarization and wide wavelength-tunable range are needed. (letter)

  14. Studies on γ-ray induced structural changes in Nd{sup 3+} doped lead alumino silicate glasses by means of thermoluminescence for dosimetric applications in high dose ranges

    Energy Technology Data Exchange (ETDEWEB)

    Sundara Rao, M. [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522 510, Guntur, A.P. (India); Gandhi, Y. [Department of Physics, Kakani Venkata Ratnam College, Nandigama 521 185, A.P. (India); Sanyal, Bhaskar [Food Technology Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Bhargavi, K. [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522 510, Guntur, A.P. (India); Piasecki, M. [Institute of Physics, J. Dlugosz University, Ul. Armii Krajowej 13/15, 42-201 Czestochowa (Poland); Veeraiah, N., E-mail: nvr8@rediffmail.com [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522 510, Guntur, A.P. (India)

    2014-12-15

    Graphical abstract: TL glow curves of PbO–SiO{sub 2}:Nd{sup 3+} glasses mixed with different concentrations of Al{sub 2}O{sub 3} exposed to γ-rays of dose 5.0 kGy. - Highlights: • TL studies of Nd{sup 3+} ions doped lead alumino silicate glasses were carried out. • Highest TL output was observed in the glasses mixed with 10 mol% of Al{sub 2}O{sub 3}. • Different mechanisms responsible for TL emission were discussed. • Near linearity of the dose response was observed in the dose range of 1.0–3.0 kGy. • These glasses may be useful as dosimeters in processing perishable food commodities. - Abstract: Thermoluminescence (TL) studies on PbO–Al{sub 2}O{sub 3}–SiO{sub 2}:Nd{sup 3+} glasses mixed with varying concentrations of Al{sub 2}O{sub 3} exposed to γ-rays of dose in the range 0–5.0 kGy were carried out. The TL emission exhibited a dosimetric peak at about 185 °C. The TL output under the glow peak increased with increasing Al{sub 2}O{sub 3} and also with the γ-ray dose. The mechanisms responsible for TL emission and enhancement of TL output with increase in the concentration of Al{sub 2}O{sub 3} were quantitatively discussed in terms of induced structural defects in the vicinity of Nd{sup 3+} ions due to interaction of γ-rays with the glass network in the scenario of varying concentration of Al{sub 2}O{sub 3}. The dose response of these glass samples exhibited linear behavior in the medium dose range viz., 1.0–3.0 kGy. Finally, it is concluded that the glass containing the highest concentration of Al{sub 2}O{sub 3} exhibits high TL output and such glasses are useful for dosimetry in the range 1.0–3.0 kGy and hence these glasses may be useful for dosimetry in such high range of doses required for commercial radiation processing of perishable food commodities to extend their shelf-lives.

  15. A CHF Model in Narrow Gaps under Saturated Boiling

    International Nuclear Information System (INIS)

    Park, Suki; Kim, Hyeonil; Park, Cheol

    2014-01-01

    Many researchers have paid a great attention to the CHF in narrow gaps due to enormous industrial applications. Especially, a great number of researches on the CHF have been carried out in relation to nuclear safety issues such as in-vessel retention for nuclear power plants during a severe accident. Analytical studies to predict the CHF in narrow gaps have been also reported. Yu et al. (2012) developed an analytical model to predict the CHF on downward facing and inclined heaters based on the model of Kandlikar et al. (2001) for an upward facing heater. A new theoretical model is developed to predict the CHF in narrow gaps under saturated pool boiling. This model is applicable when one side of coolant channels or both sides are heated including the effects of heater orientation. The present model is compared with the experimental CHF data obtained in narrow gaps. A new analytical CHF model is proposed to predict CHF for narrow gaps under saturated pool boiling. This model can be applied to one-side or two-sides heating surface and also consider the effects of heater orientation on CHF. The present model is compared with the experimental data obtained in narrow gaps with one heater. The comparisons indicate that the present model shows a good agreement with the experimental CHF data in the horizontal annular tubes. However, it generally under-predicts the experimental data in the narrow rectangular gaps except the data obtained in the gap thickness of 10 mm and the horizontal downward facing heater

  16. 110. PTB seminar: Dose rate measurements of ionizing radiation in the range of natural ambient radiation. Proceedings

    International Nuclear Information System (INIS)

    Lauterbach, U.; Pessara, W.; Woehler-Figgen, S.

    1997-12-01

    Measuring instruments for radiation dose measurement in the range of natural ambient radiation are not subject to legal obligations for calibration and the PTB received numerous requests in the past, asking for measures to be taken in order to ensure reliability of measuring results in this range of radiation. This has induced PTB to organise the seminar, intended to present the current status of measuring technology in this field, reveal problems encountered in practical applications, and discuss suitable ction for quality assurance. The papers of the seminar report the measuring performance and capabilities of the available instruments, results of comparative analyses of measurements, and resulting proposed action for quality assurance. Discussions concluding the sessions are also presented in the processdings volume. (orig./CB) [de

  17. Electron correlations in narrow band systems

    International Nuclear Information System (INIS)

    Kishore, R.

    1983-01-01

    The effect of the electron correlations in narrow bands, such as d(f) bands in the transition (rare earth) metals and their compounds and the impurity bands in doped semiconductors is studied. The narrow band systems is described, by the Hubbard Hamiltonian. By proposing a local self-energy for the interacting electron, it is found that the results are exact in both atomic and band limits and reduce to the Hartree Fock results for U/Δ → 0, where U is the intra-atomic Coulomb interaction and Δ is the bandwidth of the noninteracting electrons. For the Lorentzian form of the density of states of the noninteracting electrons, this approximation turns out to be equivalent to the third Hubbard approximation. A simple argument, based on the mean free path obtained from the imaginary part of the self energy, shows how the electron correlations can give rise to a discontinous metal-nonmetal transition as proposed by Mott. The band narrowing and the existence of the satellite below the Fermi energy in Ni, found in photoemission experiments, can also be understood. (Author) [pt

  18. Milnacipran affects mouse impulsive, aggressive, and depressive-like behaviors in a distinct dose-dependent manner

    Directory of Open Access Journals (Sweden)

    Iku Tsutsui-Kimura

    2017-07-01

    Full Text Available Serotonin/noradrenaline reuptake inhibitors (SNRIs are widely used for the treatment for major depressive disorder, but these drugs induce several side effects including increased aggression and impulsivity, which are risk factors for substance abuse, criminal involvement, and suicide. To address this issue, milnacipran (0, 3, 10, or 30 mg/kg, an SNRI and antidepressant, was intraperitoneally administered to mice prior to the 3-choice serial reaction time task, resident–intruder test, and forced swimming test to measure impulsive, aggressive, and depressive-like behaviors, respectively. A milnacipran dose of 10 mg/kg suppressed all behaviors, which was accompanied by increased dopamine and serotonin levels in the medial prefrontal cortex (mPFC but not in the nucleus accumbens (NAc. Although the most effective dose for depressive-like behavior was 30 mg/kg, the highest dose increased aggressive behavior and unaffected impulsive behavior. Increased dopamine levels in the NAc could be responsible for the effects. In addition, the mice basal impulsivity was negatively correlated with the latency to the first agonistic behavior. Thus, the optimal dose range of milnacipran is narrower than previously thought. Finding drugs that increase serotonin and dopamine levels in the mPFC without affecting dopamine levels in the NAc is a potential strategy for developing novel antidepressants.

  19. Associations between Narrow Angle and Adult Anthropometry: The Liwan Eye Study

    Science.gov (United States)

    Jiang, Yuzhen; He, Mingguang; Friedman, David S.; Khawaja, Anthony P.; Lee, Pak Sang; Nolan, Winifred P.; Yin, Qiuxia; Foster, Paul J.

    2015-01-01

    Purpose To assess the associations between narrow angle and adult anthropometry. Methods Chinese adults aged 50 years and older were recruited from a population-based survey in the Liwan District of Guangzhou, China. Narrow angle was defined as the posterior trabecular meshwork not visible under static gonioscopy in at least three quadrants (i.e. a circumference of at least 270°). Logistic regression models were used to examine the associations between narrow angle and anthropomorphic measures (height, weight and body mass index, BMI). Results Among the 912 participants, lower weight, shorter height, and lower BMI were significantly associated with narrower angle width (tests for trend: mean angle width in degrees vs weight p<0.001; vs height p<0.001; vs BMI p = 0.012). In univariate analyses, shorter height, lower weight and lower BMI were all significantly associated with greater odds of narrow angle. The crude association between height and narrow angle was largely attributable to a stronger association with age and sex. Lower BMI and weight remained significantly associated with narrow angle after adjustment for height, age, sex, axial ocular biometric measures and education. In analyses stratified by sex, the association between BMI and narrow angle was only observed in women. Conclusion Lower BMI and weight were associated with significantly greater odds of narrow angle after adjusting for age, education, axial ocular biometric measures and height. The odds of narrow angle increased 7% per 1 unit decrease in BMI. This association was most evident in women. PMID:24707840

  20. A naturally narrow positive-parity Θ+

    International Nuclear Information System (INIS)

    Carlson, Carl E.; Carone, Christopher D.; Kwee, Herry J.; Nazaryan, Vahagn

    2004-01-01

    We present a consistent color-flavor-spin-orbital wave function for a positive-parity Θ + that naturally explains the observed narrowness of the state. The wave function is totally symmetric in its flavor-spin part and totally antisymmetric in its color-orbital part. If flavor-spin interactions dominate, this wave function renders the positive-parity Θ + lighter than its negative-parity counterpart. We consider decays of the Θ + and compute the overlap of this state with the kinematically allowed final states. Our results are numerically small. We note that dynamical correlations between quarks are not necessary to obtain narrow pentaquark widths

  1. Subglottic cysts and asymmetrical subglottic narrowing on neck radiograph

    International Nuclear Information System (INIS)

    Holinger, L.D.; Torium, D.M.; Anandappa, E.C.

    1988-01-01

    The congenital subglottic hemangioma typically appears as an asymmetric subglottic narrowing or mass on frontal neck radiograph. Therefore, soft tissue neck radiography has been advocated as a definitive non-operative approach for diagnosing these lesions. However, we have noted similar asymmetric subglottic narrowing in patients with acquired subglottic cysts. These retention cysts occur following long-term intubation in the neonate. The mechanism probably involves subglottic fibrosis which obstructs glands with subsequent cyst formation. Acquired subglottic cysts typically appear as an asymmetric narrowing on frontal or lateral soft tissue neck radiographs. These lesions may produce airway compromise but are effectively treated by forceps or laser removal. Acquired subglottic cysts must be included in the differential diagnosis of asymmetric subglottic narrowing. The definitive diagnosis is made by direct laryngoscopy, not soft tissue neck radiograph. (orig.)

  2. Experiment study of the onset of nucleate boiling in narrow annular channel

    International Nuclear Information System (INIS)

    Wang Jiaqiang; Jia Dounan; Guo Yun

    2004-01-01

    The onset of nucleate boiling (ONB) was investigated for water flowing in the annular duct which clearance is 1.2 mm at the pressure range from 1.0 to 4.5 MPa. The effect on ONB of some thermodynamics parameters was also analyzed. The available data dealing with sub-cooled boiling initial point of water in narrow annular clearance duct are analyzed by using regression method. The new developed correlation was obtained by considering the bilateral heating factor

  3. Industrial Strategy and the Regions : the shortcomings of a narrow sectoral focus

    OpenAIRE

    Fothergill, Stephen; Gore, Tony; Wells, Peter

    2017-01-01

    Key points\\ud  - The new money that the UK government has allocated to support its industrial strategy is targeted at R&D in an exceptionally narrow range of sectors – healthcare & medicine, robotics & artificial intelligence, batteries, self-driving vehicles, materials for the future and satellites & space technology.\\ud  - Even on a generous definition of the industries that might benefit from the new Industrial Strategy Challenge Fund, these sectors account for little more than 1 per cen...

  4. Possibility of narrow resonances of the omega anti omega-system

    International Nuclear Information System (INIS)

    Duerr, H.P.

    1975-01-01

    The possibility of resonances of the Ω anti Ω-system is discussed on the basis of the medium and long range meson exchange forces. The total and partial widths of these resonances are estimated by using well known formulas of nuclear physics. It is demonstrated that analogously the phi- and rho-mesons may be interpreted as p-states of the K anti K- and π π-system, respectively. There appears, however, only a slim chance to interpret the new narrow resonances psi (3100) and psi (3700) as 7 d 1 - and 7 g 1 -Ω anti Ω configurations

  5. Design, Construction, Demonstration and Delivery of an Automated Narrow Gap Welding System.

    Science.gov (United States)

    1982-06-29

    DESIGN, CONSTRUCTION, DEMONSTRATION AND DELIVERY OF WE DA4I &NARROW GAP CONTRACT NO. NOOGOO-81-C-E923 TO DAVID TAYLOR NAVAL RESEARCH AND DEVELOPMENT...the automated * Narrow Gap welding process, is the narrow (3/8 - inch), square-butt joint *design. This narrow joint greatly reduces the volume of weld...AD-i45 495 DESIGN CONSTRUCTION DEMONSTRATION AiND DELIVERY OF RN 1/j AUrOMATED NARROW GAP WELDING SYSTEMI() CRC AUTOMATIC WELDING CO HOUSTON TX 29

  6. Narrow Escape of Interacting Diffusing Particles

    Science.gov (United States)

    Agranov, Tal; Meerson, Baruch

    2018-03-01

    The narrow escape problem deals with the calculation of the mean escape time (MET) of a Brownian particle from a bounded domain through a small hole on the domain's boundary. Here we develop a formalism which allows us to evaluate the nonescape probability of a gas of diffusing particles that may interact with each other. In some cases the nonescape probability allows us to evaluate the MET of the first particle. The formalism is based on the fluctuating hydrodynamics and the recently developed macroscopic fluctuation theory. We also uncover an unexpected connection between the narrow escape of interacting particles and thermal runaway in chemical reactors.

  7. Forced convective boiling heat transfer of water in vertical rectangular narrow channel

    International Nuclear Information System (INIS)

    Chen, Chong; Gao, Pu-zhen; Tan, Si-chao; Chen, Han-ying; Chen, Xian-bing

    2015-01-01

    Highlights: • Chen correlation cannot well predict the coefficient of rectangular channel. • Kim and Mudawar correlation is the best one among the Chen type correlations. • Lazarek and Black correlation predicted 7.0% of data within the ±30% error band. • The new correlation can well predict the coefficient with a small MAE of 14.4%. - Abstract: In order to research the characteristics of boiling flows in a vertical rectangular narrow channel, a series of convective boiling heat transfer experiments are performed. The test section is made of stainless steel with an inner diameter of 2 × 40 mm and heated length of 1100 mm. The 3194 experimental data points are obtained for a heat flux range of 10–700 kW/m 2 , a mass flux range of 200–2400 kg/m 2 s, a system pressure range of 0.1–2.5 MPa, and a quality range of 0–0.8. Eighteen prediction models are used to predict the flow boiling heat transfer coefficient of the rectangular narrow channel and the predicted value is compared against the database including 3194 data points, the results show that Chen type correlations and Lazarek and Black type correlations are not suitable for the rectangular channel very much. The Kim and Mudawar correlation is the best one among the 18 models. A new correlation is developed based on the superposition concept of nucleate boiling and convective boiling. the new correlation is shown to provide a good prediction against the database, evidenced by an overall MAE of 14.4%, with 95.2% and 98.6% of the data falling within ±30% and ±35% error bands, respectively

  8. A review of radiology staff doses and dose monitoring requirements

    International Nuclear Information System (INIS)

    Martin, C. J.

    2009-01-01

    Studies of radiation doses received during X-ray procedures by radiology, cardiology and other clinical staff have been reviewed. Data for effective dose (E), and doses to the eyes, thyroid, hands and legs have been analysed. These data have been supplemented with local measurements to determine the most exposed part of the hand for monitoring purposes. There are ranges of 60-100 in doses to individual tissues reported in the literature for similar procedures at different centres. While ranges in the doses per unit dose-area product (DAP) are between 10 and 25, large variations in dose result from differences in the sensitivity of the X-ray equipment, the type of procedure and the operator technique, but protection factors are important in maintaining dose levels as low as possible. The influence of shielding devices is significant for determining the dose to the eyes and thyroid, and the position of the operator, which depends on the procedure, is the most significant factor determining doses to the hands. A second body dosemeter worn at the level of the collar is recommended for operators with high workloads for use in assessment of effective dose and the dose to the eye. It is proposed that the third quartile values from the distributions of dose per unit DAP identified in the review might be employed in predicting the orders of magnitude of doses to the eye, thyroid and hands, based on interventional operator workloads. Such dose estimates could be employed in risk assessments when reviewing protection and monitoring requirements. A dosemeter worn on the little finger of the hand nearest to the X-ray tube is recommended for monitoring the hand. (authors)

  9. Narrow Framing and Long-Term Care Insurance

    OpenAIRE

    Daniel Gottlieb; Olivia S. Mitchell

    2015-01-01

    We propose a model of narrow framing in insurance and test it using data from a new module we designed and fielded in the Health and Retirement Study. We show that respondents subject to narrow framing are substantially less likely to buy long-term care insurance than average. This effect is distinct from, and much larger than, the effects of risk aversion or adverse selection, and it offers a new explanation for why people underinsure their later-life care needs.

  10. Narrow n anti n resonances

    International Nuclear Information System (INIS)

    Bogdanova, L.N.; Dalkarov, O.D.; Kerbikov, B.O.; Shapiro, I.S.

    1975-01-01

    The present status of the problem of quasinuclear states in systems of nucleons and antinucleons is reviewed. The theoretical predictions are compared with experimental data on narrow meson resonances near N anti N threshold which appeared in 1971-74

  11. Pool Boiling CHF in Inclined Narrow Annuli

    International Nuclear Information System (INIS)

    Kang, Myeong Gie

    2010-01-01

    Pool boiling heat transfer has been studied extensively since it is frequently encountered in various heat transfer equipment. Recently, it has been widely investigated in nuclear power plants for application to the advanced light water reactors designs. Through the review on the published results it can be concluded that knowledge on the combined effects of the surface orientation and a confined space on pool boiling heat transfer is of great practical importance and also of great academic interest. Fujita et al. investigated pool boiling heat transfer, from boiling inception to the critical heat flux (CHF, q' CHF ), in a confined narrow space between heated and unheated parallel rectangular plates. They identified that both the confined space and the surface orientation changed heat transfer much. Kim and Suh changed the surface orientation angles of a downward heating rectangular channel having a narrow gap from the downward-facing position (180 .deg.) to the vertical position (90 .deg.). They observed that the CHF generally decreased as the inclination angle (θ ) increased. Yao and Chang studied pool boiling heat transfer in a confined heat transfer for vertical narrow annuli with closed bottoms. They observed that when the gap size ( s ) of the annulus was decreased the effect of space confinement to boiling heat transfer increased. The CHF was occurred at much lower value for the confined space comparing to the unconfined pool boiling. Pool boiling heat transfer in narrow horizontal annular crevices was studied by Hung and Yao. They concluded that the CHF decreased with decreasing gap size of the annuli and described the importance of the thin film evaporation to explain the lower CHF of narrow crevices. The effect of the inclination angle on the CHF on countercurrent boiling in an inclined uniformly heated tube with closed bottoms was also studied by Liu et al. They concluded that the CHF reduced with the inclination angle decrease. A study was carried out

  12. II-VI Narrow-Bandgap Semiconductors for Optoelectronics

    Science.gov (United States)

    Baker, Ian

    The field of narrow-gap II-VI materials is dominated by the compound semiconductor mercury cadmium telluride, (Hg1-x Cd x Te or MCT), which supports a large industry in infrared detectors, cameras and infrared systems. It is probably true to say that HgCdTe is the third most studied semiconductor after silicon and gallium arsenide. Hg1-x Cd x Te is the material most widely used in high-performance infrared detectors at present. By changing the composition x the spectral response of the detector can be made to cover the range from 1 μm to beyond 17 μm. The advantages of this system arise from a number of features, notably: close lattice matching, high optical absorption coefficient, low carrier generation rate, high electron mobility and readily available doping techniques. These advantages mean that very sensitive infrared detectors can be produced at relatively high operating temperatures. Hg1-x Cd x Te multilayers can be readily grown in vapor-phase epitaxial processes. This provides the device engineer with complex doping and composition profiles that can be used to further enhance the electro-optic performance, leading to low-cost, large-area detectors in the future. The main purpose of this chapter is to describe the applications, device physics and technology of II-VI narrow-bandgap devices, focusing on HgCdTe but also including Hg1-x Mn x Te and Hg1-x Zn x Te. It concludes with a review of the research and development programs into third-generation infrared detector technology (so-called GEN III detectors) being performed in centers around the world.

  13. Narrow-Band Imaging: Clinical Application in Gastrointestinal Endoscopy

    Directory of Open Access Journals (Sweden)

    Sandra Barbeiro

    2018-03-01

    Full Text Available Narrow-band imaging is an advanced imaging system that applies optic digital methods to enhance endoscopic images and improves visualization of the mucosal surface architecture and microvascular pattern. Narrow-band imaging use has been suggested to be an important adjunctive tool to white-light endoscopy to improve the detection of lesions in the digestive tract. Importantly, it also allows the distinction between benign and malignant lesions, targeting biopsies, prediction of the risk of invasive cancer, delimitation of resection margins, and identification of residual neoplasia in a scar. Thus, in expert hands it is a useful tool that enables the physician to decide on the best treatment (endoscopic or surgical and management. Current evidence suggests that it should be used routinely for patients at increased risk for digestive neoplastic lesions and could become the standard of care in the near future, at least in referral centers. However, adequate training programs to promote the implementation of narrow-band imaging in daily clinical practice are needed. In this review, we summarize the current scientific evidence on the clinical usefulness of narrow-band imaging in the diagnosis and characterization of digestive tract lesions/cancers and describe the available classification systems.

  14. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  15. Investigation of mean glandular dose versus compressed breast thickness relationship for mammography

    International Nuclear Information System (INIS)

    Bor, D.; Tukel, S.; Olgar, T.; Toklu, T.; Aydin, E.; Akyol, O.

    2008-01-01

    The relationship between the mean glandular dose (MGD) and the compressed breast thickness (CBT) is commonly used for the presentation of mammographic dose survey results and could also be useful for the assessment of individual breast doses retrospectively in case of lack of necessary dosimetric instrumentation. The high data scattering from the best fit reduces the reliability of this technique. The aim of this study was to investigate the accuracy of this relationship using the data collected from a patient survey and phantom experiment. Patients were divided into three different groups according to their breast glandularities, which were predicted from the inspection of previous mammograms. X-ray beam qualities that will be used in patient examinations were determined according to breast thickness and predicted glandularities. The MGD versus CBT relationship for all the examined patients resulted in a poor correlation (R 2 = 0.28). This relationship was separately obtained for each glandularity group and also for sub-groups of specific beam qualities. The best correlation (R 2 = 0.73) was obtained for the fatty breast group and Mo/Mo combination. A low correlation (R 2 = 0.34) was observed in the mid-glandularity group due to inclusion of a wide range of glandularities in this group. In the case of the dense breast group, although the glandularity range was narrow, there were e still high data scattering (R 2 = 0.25). This was probably due to the use of Mo/Rh and Mo/Mo combinations. This is validated by obtaining the MGD-CBT relationship specific to Mo/Mo combination (R 2 = 0.61). (authors)

  16. Single-graded CIGS with narrow bandgap for tandem solar cells.

    Science.gov (United States)

    Feurer, Thomas; Bissig, Benjamin; Weiss, Thomas P; Carron, Romain; Avancini, Enrico; Löckinger, Johannes; Buecheler, Stephan; Tiwari, Ayodhya N

    2018-01-01

    Multi-junction solar cells show the highest photovoltaic energy conversion efficiencies, but the current technologies based on wafers and epitaxial growth of multiple layers are very costly. Therefore, there is a high interest in realizing multi-junction tandem devices based on cost-effective thin film technologies. While the efficiency of such devices has been limited so far because of the rather low efficiency of semitransparent wide bandgap top cells, the recent rise of wide bandgap perovskite solar cells has inspired the development of new thin film tandem solar devices. In order to realize monolithic, and therefore current-matched thin film tandem solar cells, a bottom cell with narrow bandgap (~1 eV) and high efficiency is necessary. In this work, we present Cu(In,Ga)Se 2 with a bandgap of 1.00 eV and a maximum power conversion efficiency of 16.1%. This is achieved by implementing a gallium grading towards the back contact into a CuInSe 2 base material. We show that this modification significantly improves the open circuit voltage but does not reduce the spectral response range of these devices. Therefore, efficient cells with narrow bandgap absorbers are obtained, yielding the high current density necessary for thin film multi-junction solar cells.

  17. Narrow in-gap states in doped Al2O3

    KAUST Repository

    Casas-Cabanas, Montse; Fré sard, Marion; Lü ders, Ulrike; Fré sard, Raymond; Schuster, Cosima B.; Schwingenschlö gl, Udo

    2011-01-01

    Based on XRD data testifying that the M ions occupy substitutional sites, transmittance measurement are discussed in comparison to electronic structure calculations for M-doped Al2O3 with M = V, Mn, and Cr. The M 3d states are found approximatively 2 eV above the top of the host valence band. The fundamental band gap of Al2O3 is further reduced in the V and Mn cases due to a splitting of the narrow band at the Fermi energy. Nevertheless the measured transmittance in the visible range remains high in all three cases. © 2011 Elsevier B.V. All rights reserved.

  18. Narrow in-gap states in doped Al2O3

    KAUST Repository

    Casas-Cabanas, Montse

    2011-10-01

    Based on XRD data testifying that the M ions occupy substitutional sites, transmittance measurement are discussed in comparison to electronic structure calculations for M-doped Al2O3 with M = V, Mn, and Cr. The M 3d states are found approximatively 2 eV above the top of the host valence band. The fundamental band gap of Al2O3 is further reduced in the V and Mn cases due to a splitting of the narrow band at the Fermi energy. Nevertheless the measured transmittance in the visible range remains high in all three cases. © 2011 Elsevier B.V. All rights reserved.

  19. Experimental study on the boiling phenomena within a narrow gap

    International Nuclear Information System (INIS)

    Aoki, S.; Inoue, A.; Aritomi, M.; Sakamoto, Y.

    1982-01-01

    Experiments were carried out with annular narrow gaps having the gap widths 0.2,0.3,0.4,0.5,1.0 and 1.5 mm for the following two cases: (a) for the ''open bottom'' case, the heat transfer coefficient was improved as the gap width decreases, but it was not affected by gap lengths in the range 40 <= L <= 100 mm. (b) for the ''closed bottom'' case, the heat transfer coefficient was not affected by gap width or length. The transition heat flux could be correlated by the equivalent gap length defined in terms of the cross-sectional area of the open end. (author)

  20. Milnacipran affects mouse impulsive, aggressive, and depressive-like behaviors in a distinct dose-dependent manner.

    Science.gov (United States)

    Tsutsui-Kimura, Iku; Ohmura, Yu; Yoshida, Takayuki; Yoshioka, Mitsuhiro

    2017-07-01

    Serotonin/noradrenaline reuptake inhibitors (SNRIs) are widely used for the treatment for major depressive disorder, but these drugs induce several side effects including increased aggression and impulsivity, which are risk factors for substance abuse, criminal involvement, and suicide. To address this issue, milnacipran (0, 3, 10, or 30 mg/kg), an SNRI and antidepressant, was intraperitoneally administered to mice prior to the 3-choice serial reaction time task, resident-intruder test, and forced swimming test to measure impulsive, aggressive, and depressive-like behaviors, respectively. A milnacipran dose of 10 mg/kg suppressed all behaviors, which was accompanied by increased dopamine and serotonin levels in the medial prefrontal cortex (mPFC) but not in the nucleus accumbens (NAc). Although the most effective dose for depressive-like behavior was 30 mg/kg, the highest dose increased aggressive behavior and unaffected impulsive behavior. Increased dopamine levels in the NAc could be responsible for the effects. In addition, the mice basal impulsivity was negatively correlated with the latency to the first agonistic behavior. Thus, the optimal dose range of milnacipran is narrower than previously thought. Finding drugs that increase serotonin and dopamine levels in the mPFC without affecting dopamine levels in the NAc is a potential strategy for developing novel antidepressants. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  1. Clinical and electrophysiological characteristics of patients with paroxysmal intra-His block with narrow QRS complexes.

    Science.gov (United States)

    Ragupathi, Loheetha; Johnson, Drew; Greenspon, Arnold; Frisch, Daniel; Ho, Reginald T; Pavri, Behzad B

    2018-04-18

    Atrioventricular (AV) block is usually due to infranodal disease and associated with a wide QRS complex; such patients often progress to complete AV block and pacemaker dependency. Uncommonly, infranodal AV block can occur within the His bundle with a narrow QRS complex. The aims of this study were to define clinical/echocardiographic characteristics of patients with AV block within the His bundle and report progression to pacemaker dependency. We retrospectively identified patients with narrow QRS complexes and documented intra-His delay or block at electrophysiology study (group A) or with electrocardiogram-documented Mobitz II AV block/paroxysmal AV block (group B). Clinical, electrophysiological, and echocardiographic variables at presentation and pacemaker parameters at the last follow-up visit were evaluated. Twenty-seven patients (19 women) were identified (mean age 64 ± 13 years; range, 38-85 years). Four patients who had block with narrow QRS complexes rarely progress to pacemaker dependency and require infrequent pacing. This entity is more common in women, with a higher prevalence of aortic and/or mitral annular calcification. If confirmed by additional studies, single-chamber pacemaker may be sufficient. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  2. Investigation of the spatial resolution of an online dose verification device

    International Nuclear Information System (INIS)

    Asuni, G.; Rickey, D. W.; McCurdy, B. M. C.

    2012-01-01

    Purpose: The aim of this work is to characterize a new online dose verification device, COMPASS transmission detector array (IBA Dosimetry, Schwarzenbruck, Germany). The array is composed of 1600 cylindrical ionization chambers of 3.8 mm diameter, separated by 6.5 mm center-to-center spacing, in a 40 x 40 arrangement. Methods: The line spread function (LSF) of a single ion chamber in the detector was measured with a narrow slit collimator for a 6 MV photon beam. The 0.25 x 10 mm 2 slit was formed by two machined lead blocks. The LSF was obtained by laterally translating the detector in 0.25 mm steps underneath the slit over a range of 24 mm and taking a measurement at each step. This measurement was validated with Monte Carlo simulation using BEAMnrc and DOSXYZnrc. The presampling modulation transfer function (MTF), the Fourier transform of the line spread function, was determined and compared to calculated (Monte Carlo and analytical) MTFs. Two head-and-neck intensity modulated radiation therapy (IMRT) fields were measured using the device and were used to validate the LSF measurement. These fields were simulated with the BEAMnrc Monte Carlo model, and the Monte Carlo generated incident fluence was convolved with the 2D detector response function (derived from the measured LSF) to obtain calculated dose. The measured and calculated dose distributions were then quantitatively compared using χ-comparison criteria of 3% dose difference and 3 mm distance-to-agreement for in-field points (defined as those above the 10% maximum dose threshold). Results: The full width at half-maximum (FWHM) of the measured detector response for a single chamber is 4.3 mm, which is comparable to the chamber diameter of 3.8 mm. The pre-sampling MTF was calculated, and the resolution of one chamber was estimated as 0.25 lp/mm from the first zero crossing. For both examined IMRT fields, the χ-comparison between measured and calculated data show good agreement with 95.1% and 96.3% of in

  3. Dashboard systems: Pharmacokinetic/pharmacodynamic mediated dose optimization for monoclonal antibodies.

    Science.gov (United States)

    Mould, Diane R; Dubinsky, Marla C

    2015-03-01

    Many marketed drugs exhibit high variability in exposure and response. While these drugs are efficacious in their approved indications, finding appropriate dose regimens for individual patients is not straightforward. Similar dose adjustment problems are also seen with drugs that have a complex relationship between exposure and response and/or a narrow therapeutic window. This is particularly true for monoclonal antibodies, where prolonged dosing at a sub-therapeutic dose can also elicit anti-drug antibodies which will further compromise safety and efficacy. Thus, finding appropriate doses quickly would represent a substantial improvement in healthcare. Dashboard systems, which are decision-support tools, offer an improved, convenient means of tailoring treatment for individual patients. This article reviews the clinical need for this approach, particularly with monoclonal antibodies, the design, development, and testing of such systems, and the likely benefits of dashboard systems in clinical practice. We focus on infliximab for reference. © 2015, The American College of Clinical Pharmacology.

  4. Widely tunable narrow-band coherent Terahertz radiation from an undulator at THU

    Science.gov (United States)

    Su, X.; Wang, D.; Tian, Q.; Liang, Y.; Niu, L.; Yan, L.; Du, Y.; Huang, W.; Tang, C.

    2018-01-01

    There is anxious demand for intense widely tunable narrow-band Terahertz (THz) radiation in scientific research, which is regarded as a powerful tool for the coherent control of matter. We report the generation of widely tunable THz radiation from a planar permanent magnet undulator at Tsinghua University (THU). A relativistic electron beam is compressed by a magnetic chicane into sub-ps bunch length to excite THz radiation in the undulator coherently. The THz frequency can be tuned from 0.4 THz to 10 THz continuously with narrow-band spectrums when the undulator gap ranges from 23 mm to 75 mm. The measured pulse THz radiation energy from 220 pC bunch is 3.5 μJ at 1 THz and tens of μJ pulse energy (corresponding peak power of 10 MW) can be obtained when excited by 1 nC beam extrapolated from the property of coherent radiation. The experimental results agree well with theoretical predictions, which demonstrates a suitable THz source for the many applications that require intense and widely tunable THz sources.

  5. Tofacitinib in patients with ankylosing spondylitis: a phase II, 16-week, randomised, placebo-controlled, dose-ranging study.

    Science.gov (United States)

    van der Heijde, Désirée; Deodhar, Atul; Wei, James C; Drescher, Edit; Fleishaker, Dona; Hendrikx, Thijs; Li, David; Menon, Sujatha; Kanik, Keith S

    2017-08-01

    To compare efficacy and safety of various doses of tofacitinib, an oral Janus kinase inhibitor, with placebo in patients with active ankylosing spondylitis (AS, radiographic axial spondyloarthritis). In this 16-week (12-week treatment, 4-week washout), phase II, multicentre, dose-ranging trial, adult patients with active AS were randomised (N=51, 52, 52, 52, respectively) to placebo or tofacitinib 2, 5 or 10 mg twice daily. The primary efficacy endpoint was Assessment of SpondyloArthritis International Society 20% improvement (ASAS20) response rate at week 12. Secondary endpoints included objective measures of disease activity, patient-reported outcomes and MRI of sacroiliac joints and spine. Safety was monitored. Emax model analysis of the primary endpoint predicted a tofacitinib 10 mg twice daily ASAS20 response rate of 67.4%, 27.3% higher than placebo. Supportive normal approximation analysis demonstrated tofacitinib 5 mg twice daily ASAS20 response rate significantly higher than placebo (80.8% vs 41.2%; ptofacitinib 2 and 10 mg twice daily demonstrated greater response rate than placebo (51.9% and 55.8%, respectively; not significant). Secondary endpoints generally demonstrated greater improvements with tofacitinib 5 and 10 mg twice daily than placebo. Objective (including MRI) endpoints demonstrated clear dose response. Adverse events were similar across treatment groups with no unexpected safety findings. Dose-dependent laboratory outcome changes returned close to baseline by week 16. Tofacitinib 5 and 10 mg twice daily demonstrated greater clinical efficacy versus placebo in reducing signs, symptoms and objective endpoints of active AS in adult patients with a similar 12-week safety profile as reported in other indications. NCT01786668. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Estimation of internal exposure dose from food after the Fukushima Daiichi Nuclear Power Station disaster

    International Nuclear Information System (INIS)

    Takizawa, Mari; Yoshizawa, Nobuaki; Kawai, Masaki; Miyatake, Hirokazu; Hirakawa, Sachiko; Murakami, Kana; Sato, Osamu; Takagi, Shunji; Suzuki, Gen

    2016-01-01

    In order to estimate the internal exposure dose from food due to the Fukushima Daiichi Nuclear Power Station accident, total diet study (TDS) has been carried out. TDS is a method for estimating how much of certain chemicals people intake in the normal diet. A wide range of food products are chosen as targets, and the increase or decrease of chemicals depending on processing or cooking is taken into account. This paper glanced at the transition of TDS survey results, and with a focus on the survey results of the market basket (MB) system, which is one of the TDS techniques, it examined a decrease in the committed effective dose per year of radioactive cesium. Although the values of internal exposure dose from food in Fukushima Prefecture and surrounding prefectures are even now in a relatively high tendency compared with those in the distant regions, the difference has been narrowing. According to the attenuation prediction of internal exposure dose in each region of Fukushima Prefecture, the values after 5 years from the accident will be lower than the measured value on the food in market that has been investigated during 1989 and 2005. In addition, the internal exposure dose that was the survey results based on MB system in September - October 2014 was 0.0007 to 0.0022 mSv/year. These values are very small at 1% or less of the upper limit dose of 1 mSv/year as the setting basis of current reference value in Japan. (A.O.)

  7. A randomized, double-blind, placebo-controlled, dose-ranging study using Genz-644470 and sevelamer carbonate in hyperphosphatemic chronic kidney disease patients on hemodialysis

    Directory of Open Access Journals (Sweden)

    Moustafa M

    2014-04-01

    Full Text Available Moustafa Moustafa,1 Lawrence Lehrner,2 Fahd Al-Saghir,3 Mark Smith,4 Sunita Goyal,5 Maureen Dillon,5 John Hunter,5 Randy Holmes-Farley5 1South Carolina Nephrology and Hypertension Center Inc., Orangeburg, SC, USA; 2Kidney Specialists of Southern Nevada, Las Vegas, NV, USA; 3Michigan Kidney Consultants, Pontiac, MI, USA; 4Kidney Care Associates, LLC, Augusta, GA, USA; 5Genzyme, a Sanofi company, Cambridge, MA, USA Background: Genz-644470 is a new, nonabsorbed phosphate binding polymer. In an in vitro competitive phosphate binding assay, Genz-644470 bound significantly more phosphate per gram than sevelamer. As a consequence, this clinical study evaluated the ability of Genz-644470 to lower serum phosphorus in patients on hemodialysis and compared serum phosphorus lowering of Genz-644470 with sevelamer carbonate and placebo. Because three different fixed doses of Genz-644470 and sevelamer carbonate were used, phosphate-lowering dose-responses of each agent were also analyzed. Methods: A randomized, double-blind, dose-ranging study was conducted. After a 2-week phosphate binder washout, 349 hyperphosphatemic (serum phosphorus >5.5 mg/dL hemodialysis patients were randomized to one of seven fixed-dose groups: placebo, Genz-644470 2.4 g/day, Genz-644470 4.8 g/day, Genz-644470 7.2 g/day, sevelamer carbonate 2.4 g/day, sevelamer carbonate 4.8 g/day, or sevelamer carbonate 7.2 g/day. Indicated total daily doses were administered in fixed divided doses three times a day with meals for 3 weeks. The change in serum phosphorus during the treatment period and its dose-response patterns were assessed. Results: Dose-dependent reductions in serum phosphorus were observed with both Genz-644470 and sevelamer carbonate. Serum phosphorus-lowering responses to fixed doses of sevelamer carbonate and Genz-644470 were enhanced in a roughly linear fashion with increasing doses over a threefold range after 3 weeks of treatment. Genz-644470 did not show any advantage in

  8. Conserved and narrow temperature limits in alpine insects: Thermal tolerance and supercooling points of the ice-crawlers, Grylloblatta (Insecta: Grylloblattodea: Grylloblattidae).

    Science.gov (United States)

    Schoville, Sean D; Slatyer, Rachel A; Bergdahl, James C; Valdez, Glenda A

    2015-07-01

    For many terrestrial species, habitat associations and range size are dependent on physiological limits, which in turn may influence large-scale patterns of species diversity. The temperature range experienced by individuals is considered to shape the breadth of the thermal niche, with species occupying temporally and/or geographically stable climates tolerating a narrow temperature range. High-elevation environments experience large temperature fluctuations, with frequent periods below 0 °C, but Grylloblatta (Grylloblattodea: Grylloblattidae) occupy climatically stable microhabitats within this region. Here we test critical thermal limits and supercooling points for five Grylloblatta populations from across a large geographic area, to examine whether the stable microhabitats of this group are associated with a narrow thermal niche and assess their capacity to tolerate cold conditions. Thermal limits are highly conserved in Grylloblatta, despite substantial genetic divergence among populations spanning 1500 m elevation and being separated by over 500 km. Further, Grylloblatta show exceptionally narrow thermal limits compared to other insect taxa with little capacity to improve cold tolerance via plasticity. In contrast, upper thermal limits were significantly depressed by cold acclimation. Grylloblatta maintain coordinated movement until they freeze, and they die upon freezing. Convergence of the critical thermal minima, supercooling point and lower lethal limits point to adaptation to a cold but, importantly, constant thermal environment. These physiological data provide an explanation for the high endemism and patchy distribution of Grylloblatta, which relies on subterranean retreats to accommodate narrow thermal limits. These retreats are currently buffered from temperature fluctuations by snow cover, and a declining snowpack thus places Grylloblatta at risk of exposure to temperatures beyond its tolerance capacity. Copyright © 2015 Elsevier Ltd. All rights

  9. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  10. Gonad dose in cineurethrocystography

    International Nuclear Information System (INIS)

    Ardran, G.M.; Dixon-Brown, A.; Fursdon, P.S.

    1978-01-01

    The technical factors used for cineurethrocystography for the true lateral projection in females are given. The mid-line radiation dose has been measured with LiF TLD inserted into the vagina in 19 examinations. The average dose recorded was 148 mrad, the range being 50 to 306 mrad, the average number of cine frames exposed was 96. Data obtained using a Rando phantom indicated that the average ovary dose would be 30% greater than the mid-line dose since the near ovary receives a higher dose than the more distant one. The technique used for men is also given, the average gonad dose in six men being 123 mrad, range 56 to 243 mrad when simple lead foil gonad protection was used; the average number of cine frames was 107. The dose in one man without gonad protection was 1575 mrad for 112 cine frames. The results for both sexes compare favourably with those of others reported in the literature and with gonad doses recorded in typical IVP examinations. (author)

  11. The Effect of Divided Attention on Emotion-Induced Memory Narrowing

    Science.gov (United States)

    Steinmetz, Katherine R. Mickley; Waring, Jill D.; Kensinger, Elizabeth A.

    2014-01-01

    Individuals are more likely to remember emotional than neutral information, but this benefit does not always extend to the surrounding background information. This memory narrowing is theorized to be linked to the availability of attentional resources at encoding. In contrast to the predictions of this theoretical account, altering participants’ attentional resources at encoding, by dividing attention, did not affect the emotion-induced memory narrowing. Attention was divided using three separate manipulations: a digit ordering task (Experiment 1), an arithmetic task (Experiment 2), and an auditory discrimination task (Experiment 3). Across all three experiments, divided attention decreased memory across-the-board but did not affect the degree of memory narrowing. These findings suggest that theories to explain memory narrowing must be expanded to include other potential mechanisms beyond limitations of attentional resources. PMID:24295041

  12. The effect of divided attention on emotion-induced memory narrowing.

    Science.gov (United States)

    Mickley Steinmetz, Katherine R; Waring, Jill D; Kensinger, Elizabeth A

    2014-01-01

    Individuals are more likely to remember emotional than neutral information, but this benefit does not always extend to the surrounding background information. This memory narrowing is theorised to be linked to the availability of attentional resources at encoding. In contrast to the predictions of this theoretical account, altering participants' attentional resources at encoding by dividing attention did not affect emotion-induced memory narrowing. Attention was divided using three separate manipulations: a digit ordering task (Experiment 1), an arithmetic task (Experiment 2) and an auditory discrimination task (Experiment 3). Across all three experiments, divided attention decreased memory across the board but did not affect the degree of memory narrowing. These findings suggest that theories to explain memory narrowing must be expanded to include other potential mechanisms beyond the limitations of attentional resources.

  13. Bayesian Face Recognition and Perceptual Narrowing in Face-Space

    Science.gov (United States)

    Balas, Benjamin

    2012-01-01

    During the first year of life, infants' face recognition abilities are subject to "perceptual narrowing", the end result of which is that observers lose the ability to distinguish previously discriminable faces (e.g. other-race faces) from one another. Perceptual narrowing has been reported for faces of different species and different races, in…

  14. Control of fibre laser mode-locking by narrow-band Bragg gratings

    International Nuclear Information System (INIS)

    Laegsgaard, J

    2008-01-01

    The use of narrow-band high-reflectivity fibre Bragg gratings (FBGs) as end mirrors in a fibre laser cavity with passive mode-locking provided by a semiconductor saturable absorber mirror (SESAM) is investigated numerically. The FBG is found to control the energy range of stable mode-locking, which may be shifted far outside the regime of SESAM saturation by a suitable choice of FBG and cavity length. The pulse shape is controlled by the combined effects of FBG dispersion and self-phase modulation in the fibres, and a few ps pulses can be obtained with standard uniform FBGs

  15. Thermo hydraulic analysis of narrow channel effect in supercritical-pressure light water reactor

    International Nuclear Information System (INIS)

    Zhou Tao; Chen Juan; Cheng Wanxu

    2012-01-01

    Highlights: ► Detailed thermal analysis with different narrow gaps between fuel rods is given. ► Special characteristics of narrow channels effect on heat transfer in supercritical pressure are shown. ► Reasonable size selection of gaps between fuel rods is proposed for SCWR. - Abstract: The size of the gap between fuel rods has important effects on flow and heat transfer in a supercritical-pressure light water reactor. Based on thermal analysis at different coolant flow rates, the reasonable value range of gap size between fuel rods is obtained, for which the maximum cladding temperature safety limits and installation technology are comprehensively considered. Firstly, for a given design flow rate of coolant, thermal hydraulic analysis of supercritical pressure light water reactor with different gap sizes is provided by changing the fuel rod pitch only. The results show that, by means of reducing the gap size between fuel rods, the heat transfer coefficients between coolant and fuel rod, as well as the heat transfer coefficient between coolant and water rod, would both increase noticeably. Furthermore, the maximum cladding temperature will significantly decrease when the moderator temperature is decreased but coolant temperature remains essentially constant. Meanwhile, the reduction in the maximum cladding temperature in the inner assemblies is much larger than that in the outer assemblies. In addition, the maximum cladding temperature could be further reduced by means of increasing coolant flow rate for each gap size. Finally, the characteristics of narrow channels effect are proposed, and the maximum allowable gap between fuel rods is obtained by making full use of the enhancing narrow channels effect on heat transfer, and concurrently considering installation. This could provide a theoretical reference for supercritical-pressure light water reactor design optimization, in which the effects of gap size and flow rate on heat transfer are both considered.

  16. Pharmacokinetics and dose requirements of factor VIII over the age range 3-74 years

    DEFF Research Database (Denmark)

    Björkman, Sven; Folkesson, Anna; Jönsson, Siv

    2009-01-01

    in the sparse clinical data. Model-predicted doses (based on age and body weight) to maintain a recommended 0.01 U/mL trough level of FVIII with administration on alternate days started at around 60 U/kg in the small children, decreasing to 10 U/kg or less in middle age. However, "true" dose requirements......, as estimated from individual PK parameter data, showed a much greater variation. CONCLUSION: Appropriate dosing of FVIII for prophylactic treatment cannot be calculated only from body weight and/or age. However, plausible starting doses for most patients would be 1,000 U every other day. FVIII levels should...... can be calculated according to patient characteristics, and (3) to present dosing recommendations for initiating prophylactic treatment. METHODS: A population PK model was developed using data from four PK studies on patients aged 7-74 years. The model was tested on sparse FVIII data from 42...

  17. Natural Convective Heat Transfer from Narrow Plates

    CERN Document Server

    Oosthuizen, Patrick H

    2013-01-01

    Natural Convective Heat Transfer from Narrow Plates deals with a heat transfer situation that is of significant practical importance but which is not adequately dealt with in any existing textbooks or in any widely available review papers. The aim of the book is to introduce the reader to recent studies of natural convection from narrow plates including the effects of plate edge conditions, plate inclination, thermal conditions at the plate surface and interaction of the flows over adjacent plates. Both numerical and experimental studies are discussed and correlation equations based on the results of these studies are reviewed.

  18. RETRACTED: Treatment of postoperative emetic symptoms with granisetron in women undergoing abdominal hysterectomy: a randomized, double-blind, placebo-controlled, dose-ranging study

    Directory of Open Access Journals (Sweden)

    MD Yoshitaka Fujii

    2004-07-01

    Fujii Y, Tanaka H, Somekawa Y. Treatment of postoperative emetic symptoms with granisetron in women undergoing abdominal hysterectomy: a randomised, double-blind, placebo-controlled, dose-ranging study. Current Therapeutic Research 2004;65:321–9. https://www.sciencedirect.com/science/article/pii/S0011393X04800018

  19. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    International Nuclear Information System (INIS)

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-01-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  20. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice.

    Science.gov (United States)

    Ware, J H; Sanzari, J; Avery, S; Sayers, C; Krigsfeld, G; Nuth, M; Wan, X S; Rusek, A; Kennedy, A R

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  1. Dose assessment in pediatric computerized tomography

    International Nuclear Information System (INIS)

    Vilarinho, Luisa Maria Auredine Lima

    2004-01-01

    The objective of this work was the evaluation of radiation doses in paediatric computed tomography scans, considering the high doses usually involved and the absence of any previous evaluation in Brazil. Dose values were determined for skull and abdomen examinations, for different age ranges, by using the radiographic techniques routinely used in the clinical centers investigated. Measurements were done using pencil shape ionization chambers inserted in polymethylmethacrylate (PMMA) phantoms. These were compact phantoms of different diameters were specially designed and constructed for this work, which simulate different age ranges. Comparison of results with published values showed that doses were lower than the diagnostic reference levels established to adults exams by the European Commission. Nevertheless, doses in paediatric phantoms were higher than those obtained in adult phantoms. The paediatric dose values obtained in Hospitals A and B were lower than the reference level (DRL) adopted by SHIMPTON for different age ranges. In the range 0 - 0.5 year (neonatal), the values of DLP in Hospital B were 94 por cent superior to the DRL For the 10 years old children the values of CTDI w obtained were inferior in 89 por cent for skull and 83 por cent for abdomen examinations, compared to the values published by SHRIMPTON and WALL. Our measured CTDI w values were inferior to the values presented for SHRIMPTON and HUDA, for all the age ranges and types of examinations. It was observed that the normalized dose descriptors values in children in the neonatal range were always superior to the values of doses for the adult patient. In abdomen examinations, the difference was approximately 90% for the effective dose (E) and of 57%.for CTDI w . (author)

  2. Are narrow mesons, baryons and dibaryons evidence for multiquark states?

    International Nuclear Information System (INIS)

    Tatischeff, B.; Yonnet, J.

    2000-01-01

    Several narrow structures have been progressively observed since the last fifteen years, in di-baryonic invariant mass spectra or in missing mass spectra. More recently, narrow structures were observed in baryonic and now in mesonic mass spectra. Since these small peaks appear at fixed masses, independently of the experiment, they are associated with real states. There is no room to explain these states within classical nuclear physics taking into account baryonic and mesonic degrees of freedom. An interpretation is proposed, which associate these narrow structures with two coloured quark clusters. (authors)

  3. Estimation of Electron Dose Delivered by a 0.4 MeV Accelerator from Bremsstrahlung Dose Measurements

    DEFF Research Database (Denmark)

    Karadjov, A. G.; Hansen, Jørgen-Walther

    1980-01-01

    Determination of a 0.4 MeV electron dose from a bremsstrahlung dose measurement using a converter-detector system is considered. The detector used is a Frickle dosimeter, and the converters are aluminum, copper and lead foils. Optimal converter thickness is ascertained experimentally for each mat...... materials within a Z-range of 13–82. A linear relation is found between bremsstrahlung dose and electron dose ranging from 2 to 20 Mrad. Finally the effect of converter area on detector response is studied....

  4. Water Vapor, Temperature and Wind Profiles within Maize Canopy under in-Field Rainwater Harvesting with Wide and Narrow Runoff Strips

    Directory of Open Access Journals (Sweden)

    Weldemichael A. Tesfuhuney

    2013-11-01

    Full Text Available Micrometeorological measurements were used to evaluate heat and water vapor to describe the transpiration (Ev and soil evaporation (Es processes for wide and narrow runoff strips under in-field rainwater harvesting (IRWH system. The resulting sigmoid-shaped water vapor (ea in wide and narrow runoff strips varied in lower and upper parts of the maize canopy. In wide runoff strips, lapse conditions of ea extended from lowest measurement level (LP to the upper middle section (MU and inversion was apparent at the top of the canopy. The virtual potential temperature (θv profile showed no difference in middle section, but the lower and upper portion (UP had lower  in narrow, compared to wide, strips, and LP-UP changes of 0.6 K and 1.2 K were observed, respectively. The Ev and Es within the canopy increased the ea concentration as determined by the wind order of magnitude. The ea concentration reached peak at about 1.6 kPa at a range of wind speed value of 1.4–1.8 m∙s−1 and 2.0–2.4 m∙s−1 for wide and narrow treatments, respectively. The sparse maize canopy of the wide strips could supply more drying power of the air in response to atmospheric evaporative demand compared to narrow strips. This is due to the variation in air flow in wide and narrow runoff strips that change gradients in ea for evapotranspiration processes.

  5. Search for narrow structures in pp-barπ+ and Λp-bar+- systems

    International Nuclear Information System (INIS)

    Chung, S.U.; Etkin, A.; Fernow, R.C.; Foley, K.J.; Goldman, J.H.; Kirk, H.; Kopp, J.; Lesnik, A.; Love, W.A.; Morris, T.W.; Ozaki, S.; Platner, E.D.; Protopopescu, S.D.; Saulys, A.; Weygand, D.P.; Wheeler, C.D.; Willen, E.H.; Winik, M.; Bensinger, J.; Morris, W.; Lindenbaum, S.J.; Kramer, M.A.; Mallik, U.; Bar-Yam, Z.; Dowd, J.; Kern, W.; Button-Shafer, J.; Dhar, S.; Lichti, R.

    1981-01-01

    We have performed a high-statistics search for narrow meson states (GAMMA - p interactions at 16 GeV/c and decaying into pp-barπ + or Λp-barπ +- . This is the first systematic search in channels requiring exchange of exotic mesons. The cross section for production of such states is ruled out at the 95% confidence level with upper limits ranging from approx.10 nb at 2.3 GeV to approx.40 nb at 2.8 GeV

  6. Improvement of quality of radiation indicators used for food irradiation in dose range of 3-10 kGy

    International Nuclear Information System (INIS)

    Hoang Hoa Mai; Pham Duy Duong; Nguyen Dinh Duong

    2007-01-01

    A sensitive indicators based on the polyvinyl butyral dyed with leuco-malachite green and methyl orange were made for use as devices for discriminating and monitoring radiation treatment in food irradiation. The sensitivity and stability of the indicator have been improved by using several additives such as CCl 4 in combination with di(nonylphenyl) isophthalate [dinonyl phthalate -C 6 H 4 (COOC 9 H 19 ) 2 ]. The dosimeters change their color from orange to greenish when irradiated with gamma rays or electrons to dose just about 2 kGy. The greenish continue to develop to deep-green upon the increase of dose to 7 kGy. This makes the indicators useful for the dose range of food irradiation application, especially in treatment of frozen meat and sea products for elimination of micro-organism. The quality of indicators are also improved by adjusting of factors and procedures during preparation of film and dosimeters. The indicators were produced in a stick-on label type showing attractive characteristics in use. The orange color before irradiation keep well stable for as long as 20 months under normal conditions in laboratory. The green after irradiation was maintained up to 12 months in piratical conditions of products. The indicator can be produced in big amount to supply to the irradiation facilities in Vietnam instead of imported devices. (author)

  7. High-q microring resonator with narrow free spectral range for pulse repetition rate multiplication

    DEFF Research Database (Denmark)

    Pu, Minhao; Ji, Hua; Frandsen, Lars Hagedorn

    2009-01-01

    We demonstrate a silicon-on-insulator microring resonator with a free-spectral-range of 0.32 nm, an extinction ratio of 27 dB, and a quality factor of ~140900 at 1550 nm that is used for pulse repetition-rate multiplication from 10 to 40 GHz.......We demonstrate a silicon-on-insulator microring resonator with a free-spectral-range of 0.32 nm, an extinction ratio of 27 dB, and a quality factor of ~140900 at 1550 nm that is used for pulse repetition-rate multiplication from 10 to 40 GHz....

  8. Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Bria M.; Brady, Samuel L., E-mail: samuel.brady@stjude.org; Kaufman, Robert A. [Department of Radiological Sciences, St Jude Children' s Research Hospital, Memphis, Tennessee 38105 (United States); Mirro, Amy E. [Department of Biomedical Engineering, Washington University, St Louis, Missouri 63130 (United States)

    2014-07-15

    Purpose: To investigate the correlation of size-specific dose estimate (SSDE) with absorbed organ dose, and to develop a simple methodology for estimating patient organ dose in a pediatric population (5–55 kg). Methods: Four physical anthropomorphic phantoms representing a range of pediatric body habitus were scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations to determine absolute organ dose. Phantom absolute organ dose was divided by phantom SSDE to determine correlation between organ dose and SSDE. Organ dose correlation factors (CF{sub SSDE}{sup organ}) were then multiplied by patient-specific SSDE to estimate patient organ dose. The CF{sub SSDE}{sup organ} were used to retrospectively estimate individual organ doses from 352 chest and 241 abdominopelvic pediatric CT examinations, where mean patient weight was 22 kg ± 15 (range 5–55 kg), and mean patient age was 6 yrs ± 5 (range 4 months to 23 yrs). Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm; thus, showing appropriate scalability of the phantoms across the entire pediatric population in this study. IndividualCF{sub SSDE}{sup organ} were determined for a total of 23 organs in the chest and abdominopelvic region across nine weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7–1.4) and abdominopelvic region (average 0.9; range 0.7–1.3) was near unity. For organ/tissue that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1–0.4) for both the chest and abdominopelvic regions, respectively. A means to estimate patient organ dose was demonstrated. Calculated patient organ dose, using patient SSDE and CF{sub SSDE}{sup organ}, was compared to

  9. Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    International Nuclear Information System (INIS)

    Campos, Luciana Tourinho; Leite, Sandro Passos; Almeida, Carlos Eduardo Veloso de; Magalhães, Luís Alexandre Gonçalves

    2017-01-01

    Radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. The Radiological Science Laboratory (LCR/UERJ) operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy and the dosimetric conditions of the TPS. The programme works in such a way those TLDs are sent to the centre where they are to be irradiated to a certain dose. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data. (author)

  10. Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Luciana Tourinho; Leite, Sandro Passos; Almeida, Carlos Eduardo Veloso de; Magalhães, Luís Alexandre Gonçalves, E-mail: tc_luciana@yahoo.com.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. The Radiological Science Laboratory (LCR/UERJ) operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy and the dosimetric conditions of the TPS. The programme works in such a way those TLDs are sent to the centre where they are to be irradiated to a certain dose. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data. (author)

  11. Effect of e-beam dose on the fractional density of Au-catalyzed GaAs nanowire growth

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeung Hun, E-mail: jeunghunpark@gmail.com [Department of Materials Science and Engineering, University of California Los Angeles, Los Angeles, CA 90095 (United States); Gambin, Vincent [Northrop Grumman Aerospace Systems, Redondo Beach, CA 90278 (United States); Kodambaka, Suneel, E-mail: kodambaka@ucla.edu [Department of Materials Science and Engineering, University of California Los Angeles, Los Angeles, CA 90095 (United States)

    2016-05-31

    Using Au/GaAs as a model system, the effect of initial catalyst patterning conditions on the growth of nanowire was studied. Resulting morphologies and fractional surface densities are determined as a function of e-beam dose, dot size, and inter-dot spacing using scanning and transmission electron microscopies. The majority of resulting nanowires grow randomly oriented with respect to the substrate. The nanowires are tapered with narrow tops, wider bases, and catalysts at the wire tips — characteristics of vapor–liquid–solid process. The base diameters of the wires are larger than the dot size, which is likely due to the non-catalyzed vapor–solid deposition along the sidewalls. The higher dose rate used in pattering leads to the formation of higher aspect ratio nanowires with narrower bases. The fractional surface density is found to increase linearly with the clearing dose and the critical dose for nanowire growth increases with decreasing catalyst pattern size and spacing. At a given dose, the fractional density increases with increasing Au dot size and with decreasing inter-dot spacing. Our results may provide new insights into the role of catalyst preparing conditions on the high density, wafer-scale growth of nanowires. - Highlights: • Initial Au catalyst layers are prepared using electron beam lithography. • GaAs nanowires are grown on GaAs(111)B using molecular beam epitaxy. • Effect of dose, size and spacing of Au dots on morphology and density is studied. • Density of nanowires is controlled by changing exposed dose on Au catalyst.

  12. What's in a name? Expiratory tracheal narrowing in adults explained

    International Nuclear Information System (INIS)

    Leong, P.; Bardin, P.G.; Lau, K.K.

    2013-01-01

    Tracheomalacia, tracheobronchomalacia, and excessive dynamic airway collapse are all terms used to describe tracheal narrowing in expiration. The first two describe luminal reduction from cartilage softening and the latter refers to luminal reduction from exaggerated posterior membrane movement. Expiratory tracheal narrowing is a frequent occurrence that can cause symptoms of airway obstruction, such as dyspnoea, wheeze, and exercise intolerance. The accurate diagnosis and quantification of expiratory tracheal narrowing has important aetiological, therapeutic, and prognostic implications. The reference standard for diagnosis has traditionally been bronchoscopy; however, this method has significant limitations. Expiratory tracheal disorders are readily detected by four-dimensional dynamic volume multidetector computed tomography (4D-CT), an emerging, non-invasive method that will potentially enable detection and quantification of these conditions. This review discusses the morphological forms of expiratory tracheal narrowing and demonstrates the utility of 4D-CT in the diagnosis, quantification, and treatment of these important conditions

  13. Multilayer Photonic Crystal for Spectral Narrowing of Emission

    Directory of Open Access Journals (Sweden)

    Zhanfang LIU

    2017-08-01

    Full Text Available Multilayer colloidal crystal has been prepared by the layer-by-layer deposition of silica microspheres on a glass slide. Each layer is a slab consisting of a fcc close-packed colloidal arrays. By properly choosing the sizes of spheres, the whole spectral feature of multilayer colloidal crystal can be tuned. Here, we engineered a multilayer superlattice structure with an effective passband between two stop bands. This gives a strong narrowing effect on emission spectrum. With the stop bands at the shortwave and longwave edges of emission spectrum, the passband in the central wavelength region can be regarded as a strong decrease of suppression effect and enhancement of a narrow wavelength region of emission. The spectral narrowing modification effect of suitably engineered colloidal crystals shows up their importance in potential application as optical filters and lasing devices.DOI: http://dx.doi.org/10.5755/j01.ms.23.3.16320

  14. Bandwidth-narrowed Bragg gratings inscribed in double-cladding fiber by femtosecond laser.

    Science.gov (United States)

    Shi, Jiawei; Li, Yuhua; Liu, Shuhui; Wang, Haiyan; Liu, Ningliang; Lu, Peixiang

    2011-01-31

    Bragg gratings with the bandwidth(FWHM) narrowed up to 79 pm were inscribed in double-cladding fiber with femtosecond radiation and a phase mask followed by an annealing treatment. With the annealing temperature below a critical value, the bandwidth of Bragg gratings induced by Type I-IR and Type II-IR index change was narrowed without the reduction of reflectivity. The bandwidth narrowing is due to the profile transformation of the refractive index modulation caused by the annealing treatment. This mechanism was verified by comparing bandwidth narrowing processes of FBGs written with different power densities.

  15. NEAR-BLOWOFF DYNAMICS OF BLUFF-BODY-STABILIZED PREMIXED HYDROGEN/AIR FLAMES IN A NARROW CHANNEL

    KAUST Repository

    Lee, Bok Jik; Yoo, Chun Sang; Im, Hong G.

    2015-01-01

    regular asymmetric fluctuation. When the inlet velocity is further increased, the flame is eventually blown off. Between the regular fluctuation mode and blowoff limit, there exists a narrow range of the inlet velocity where the flames exhibit periodic local extinction and recovery. Approaching further to blowoff limit, the local extinction and recovery becomes highly transient and a failure of recovery leads blowoff and extinction of the flame kernel.

  16. Influence of CYP3A5 genetic variation on everolimus maintenance dosing after cardiac transplantation.

    Science.gov (United States)

    Lesche, Dorothea; Sigurdardottir, Vilborg; Setoud, Raschid; Englberger, Lars; Fiedler, Georg M; Largiadèr, Carlo R; Mohacsi, Paul; Sistonen, Johanna

    2015-12-01

    Everolimus (ERL) has become an alternative to calcineurin inhibitors (CNIs) due to its renal-sparing properties, especially in heart transplant (HTx) recipients with kidney dysfunction. However, ERL dosing is challenging due to its narrow therapeutic window combined with high interindividual pharmacokinetic variability. Our aim was to evaluate the effect of clinical and genetic factors on ERL dosing in a pilot cohort of 37 HTx recipients. Variants in CYP3A5, CYP3A4, CYP2C8, POR, NR1I2, and ABCB1 were genotyped, and clinical data were retrieved from patient charts. While ERL trough concentration (C0 ) was within the targeted range for most patients, over 30-fold variability in the dose-adjusted ERL C0 was observed. Regression analysis revealed a significant effect of the non-functional CYP3A5*3 variant on the dose-adjusted ERL C0 (p = 0.031). ERL dose requirement was 0.02 mg/kg/d higher in patients with CYP3A5*1/*3 genotype compared to patients with CYP3A5*3/*3 to reach the targeted C0 (p = 0.041). ERL therapy substantially improved estimated glomerular filtration rate (28.6 ± 6.6 mL/min/1.73 m(2)) in patients with baseline kidney dysfunction. Everolimus pharmacokinetics in HTx recipients is highly variable. Our preliminary data on patients on a CNI-free therapy regimen suggest that CYP3A5 genetic variation may contribute to this variability. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Validation of system codes RELAP5 and SPECTRA for natural convection boiling in narrow channels

    Energy Technology Data Exchange (ETDEWEB)

    Stempniewicz, M.M., E-mail: stempniewicz@nrg.eu; Slootman, M.L.F.; Wiersema, H.T.

    2016-10-15

    Highlights: • Computer codes RELAP5/Mod3.3 and SPECTRA 3.61 validated for boiling in narrow channels. • Validated codes can be used for LOCA analyses in research reactors. • Code validation based on natural convection boiling in narrow channels experiments. - Abstract: Safety analyses of LOCA scenarios in nuclear power plants are performed with so called thermal–hydraulic system codes, such as RELAP5. Such codes are validated for typical fuel geometries applied in nuclear power plants. The question considered by this article is if the codes can be applied for LOCA analyses in research reactors, in particular exceeding CHF in very narrow channels. In order to answer this question, validation calculations were performed with two thermal–hydraulic system codes: RELAP and SPECTRA. The validation was based on natural convection boiling in narrow channels experiments, performed by Prof. Monde et al. in the years 1990–2000. In total 42 vertical tube and annulus experiments were simulated with both codes. A good agreement of the calculated values with the measured data was observed. The main conclusions are: • The computer codes RELAP5/Mod 3.3 (US NRC version) and SPECTRA 3.61 have been validated for natural convection boiling in narrow channels using experiments of Monde. The dimensions applied in the experiments were performed for a range that covers the values observed in typical research reactors. Therefore it is concluded that both codes are validated and can be used for LOCA analyses in research reactors, including natural convection boiling. The applicability range of the present validation is: hydraulic diameters of 1.1 ⩽ D{sub hyd} ⩽ 9.0 mm, heated lengths of 0.1 ⩽ L ⩽ 1.0 m, pressures of 0.10 ⩽ P ⩽ 0.99 MPa. In most calculations the burnout was predicted to occur at lower power than that observed in the experiments. In several cases the burnout was observed at higher power. The overprediction was not larger than 16% in RELAP and 15% in

  18. A Randomized Dose-Ranging Study of Neuropeptide Y in Patients with Posttraumatic Stress Disorder.

    Science.gov (United States)

    Sayed, Sehrish; Van Dam, Nicholas T; Horn, Sarah R; Kautz, Marin M; Parides, Michael; Costi, Sara; Collins, Katherine A; Iacoviello, Brian; Iosifescu, Dan V; Mathé, Aleksander A; Southwick, Steven M; Feder, Adriana; Charney, Dennis S; Murrough, James W

    2018-01-01

    Anxiety and trauma-related disorders are among the most prevalent and disabling medical conditions in the United States, and posttraumatic stress disorder in particular exacts a tremendous public health toll. We examined the tolerability and anxiolytic efficacy of neuropeptide Y administered via an intranasal route in patients with posttraumatic stress disorder. Twenty-six individuals were randomized in a cross-over, single ascending dose study into 1 of 5 cohorts: 1.4 mg (n=3), 2.8 mg (n=6), 4.6 mg (n=5), 6.8 mg (n=6), and 9.6 mg (n=6). Each individual was dosed with neuropeptide Y or placebo on separate treatment days 1 week apart in random order under double-blind conditions. Assessments were conducted at baseline and following a trauma script symptom provocation procedure subsequent to dosing. Occurrence of adverse events represented the primary tolerability outcome. The difference between treatment conditions on anxiety as measured by the Beck Anxiety Inventory and the State-Trait Anxiety Inventory immediately following the trauma script represented efficacy outcomes. Twenty-four individuals completed both treatment days. Neuropeptide Y was well tolerated up to and including the highest dose. There was a significant interaction between treatment and dose; higher doses of neuropeptide Y were associated with a greater treatment effect, favoring neuropeptide Y over placebo on Beck Anxiety Inventory score (F1,20=4.95, P=.038). There was no significant interaction for State-Trait Anxiety Inventory score. Our study suggests that a single dose of neuropeptide Y is well tolerated up to 9.6 mg and may be associated with anxiolytic effects. Future studies exploring the safety and efficacy of neuropeptide Y in stress-related disorders are warranted. The reported study is registered at: http://clinicaltrials.gov (ID: NCT01533519). © The Author(s) 2017. Published by Oxford University Press on behalf of CINP.

  19. The investigation of ship maneuvering with hydrodynamic effects between ships in curved narrow channel

    Directory of Open Access Journals (Sweden)

    Chun-Ki Lee

    2016-01-01

    Full Text Available The hydrodynamic interaction between two large vessels can't be neglected when two large vessels are closed to each other in restricted waterways such as in a harbor or narrow channel. This paper is mainly concerned with the ship maneuvering motion based on the hydrodynamic interaction effects between two large vessels moving each other in curved narrow channel. In this research, the characteristic features of the hydrodynamic interaction forces between two large vessels are described and illustrated, and the effects of velocity ratio and the spacing between two vessels are summarized and discussed. Also, the Inchon outer harbor area through the PALMI island channel in Korea was selected, and the ship maneuvering simulation was carried out to propose an appropriate safe speed and distance between two ships, which is required to avoid sea accident in confined waters. From the inspection of this investigation, it indicates the following result. Under the condition of SP12≤0.5L, it may encounter a dangerous tendency of grounding or collision due to the combined effect of the interaction between ships and external forces. Also considering the interaction and wind effect as a parameter, an overtaken and overtaking vessel in narrow channel can navigate while keeping its own original course under the following conditions; the lateral separation between two ships is about kept at 0.6 times of ship length and 15 degrees of range in maximum rudder angle. On the other hand, two ships while overtaking in curved narrow channel such as Inchon outer harbor in Korea should be navigated under the following conditions; SP12 is about kept at 1.0 times of ship length and the wind velocity should not be stronger than 10 m/s.

  20. Assessment of Organ Radiation Dose Associated with Uterine Artery Embolization

    International Nuclear Information System (INIS)

    Glomset, O.; Hellesnes, J.; Heimland, N.; Hafsahl, G.; Smith, H.J.

    2006-01-01

    Purpose: To evaluate the radiation dose to the skin, uterus, and ovaries during uterine artery embolization. Material and Methods: Guided uterine artery embolization for leiomyomata and two types of X-ray equipment with different dose levels were utilized during fluoroscopy in 20 women (ages ranging from 32 to 52 years, body weights from 55 to 68 kg). The first 13 women were treated using a non-pulsed system A, with 3.3 mm Al filtering and, for simplicity, a fixed peak voltage 80 kV. During treatment of the other 7 women, a pulsed system B with 5.4 mm Al filtering and an identical fixed voltage was used. The dose area product (DAP) was recorded. The vaginal dose of the first 13 patients and the peak skin dose of all patients were measured with thermoluminescent dosimeters (TLDs). TLDs were placed in the posterior vaginal fornix and on the skin at the beam entrance site. The uterine and ovarian doses were estimated based on the measured skin doses, normalized depth dose, and organ depth values. The effective dose (D eff ) was estimated based on the observed DAP values. The measured vaginal doses and the corresponding estimated uterine doses were compared statistically, as were the DAP values from systems A and B. Results: For system A, the mean fluoroscopic time was 20.9 min (range 12.7-31.1), and for system B 35.9 min (range 16.4-55.4). The mean numbers of angiographic exposures for systems A and B were 82 (range 30-164) and 37 (range 20-72), respectively. The mean peak skin dose for system A was 601.5 mGy (range 279-1030) and for system B 453 mGy (range 257-875). The mean DAP for system A was 88.6 Gy cm 2 (range 41.4-161.0) and for system B 52.5 Gy cm 2 (range 20.1-107.9). Statistical analysis showed a significant difference between the DAP values, the DAP for system B being the lower one. The mean estimated effective doses from systems A and B were 32 mSv (range 15.1-58.4) and 22 mSv (range 9-46), respectively. The mean estimated maximum uterine and ovarian doses

  1. Dose banding as an alternative to body surface area-based dosing of chemotherapeutic agents

    NARCIS (Netherlands)

    E. Chatelut (Etienne); M.L. White-Koning (M.); A.H.J. Mathijssen (Ron); F. Puisset (F.); S.D. Baker (Sharyn); A. Sparreboom (Alex)

    2012-01-01

    textabstractBackground: Dose banding is a recently suggested dosing method that uses predefined ranges (bands) of body surface area (BSA) to calculate each patients dose by using a single BSA-value per band. Thus, drugs with sufficient long-term stability can be prepared in advance. The main

  2. Cytogenetic effects of low-dose radiation

    International Nuclear Information System (INIS)

    Metalli, P.

    1983-01-01

    The effects of ionizing radiation on chromosomes have been known for several decades and dose-effect relationships are also fairly well established in the mid- and high-dose and dose-rate range for chromosomes of mammalian cells. In the range of low doses and dose rates of different types of radiation few data are available for direct analysis of the dose-effect relationships, and extrapolation from high to low doses is still the unavoidable approach in many cases of interest for risk assessment. A review is presented of the data actually available and of the attempts that have been made to obtain possible generalizations. Attention is focused on some specific chromosomal anomalies experimentally induced by radiation (such as reciprocal translocations and aneuploidies in germinal cells) and on their relevance for the human situation. (author)

  3. Precipitate evolution in low-nickel austenitic stainless steels during neutron irradiation at very low dose rates

    International Nuclear Information System (INIS)

    Isobe, Y.; Sagisaka, M.; Garner, F.; Okita, T.

    2007-01-01

    Full text of publication follows: Not all components of a fusion reactor will be subjected to high atomic displacement rates. Some components outside the plasma containment may experience relatively low displacement rates but data generated under long-term irradiation at low dpa rates is hard to obtain. In another study the neutron-induced microstructural evolution in response to long term irradiation at very low dose rates was studied for a Russian low-nickel austenitic stainless steel that is analogous to AISI 304. The irradiated samples were obtained from an out-of-core anti-crush support column for the BN-600 fast reactor with doses ranging from 1.5 to 22 dpa generated at 3x10 -9 to 4x10 -8 dpa/s. The irradiation temperatures were in a very narrow range of 370-375 deg. C. Microstructural observation showed that in addition to voids and dislocations, an unexpectedly high density of small carbide precipitates was formed that are not usually observed at higher dpa rates in this temperature range. These results required us to ask if such unexpected precipitation was anomalous or was a general feature of low-flux, long-term irradiation. It is shown in this paper that a similar behavior was observed in a western stainless steel, namely AISI 304 stainless steel, irradiated at similar temperatures and dpa rates in the EBR-II fast reactor, indicating that irradiation at low dpa rates for many years leads to a different precipitate microstructure and therefore different associated changes in matrix composition than are generated at higher dpa rates. One consequence of this precipitation is a reduced lattice parameter of the alloy matrix, leading to densification that increases in strength with increasing temperature and dose. A. non-destructive method to evaluate these precipitates is under development and is also discussed in this paper. (authors)

  4. Narrow linewidth pulsed optical parametric oscillator

    Indian Academy of Sciences (India)

    Tunable narrow linewidth radiation by optical parametric oscillation has many applications, particularly in spectroscopic investigation. In this paper, different techniques such as injection seeding, use of spectral selecting element like grating, grating and etalon in combination, grazing angle of incidence, entangled cavity ...

  5. Lung tumors and radon inhalation in over 2000 rats: Approximate linearity across a wide range of doses and potentiation by tobacco smoke

    International Nuclear Information System (INIS)

    Gray, R.G.; Lafuma, J.; Parish, S.E.; Peto, R.; CEA Centre d'Etudes Nucleaires de Fontenay-aux-Roses

    1986-01-01

    More than 2000 rats were exposed to cumulative doses of up to 28,000 WLMs of radon gas. More than 300 pulmonary tumors were induced by this exposure, most being nonfatal lesions detected only at autopsy of animals that had died of unrelated causes. Above 6000 WLMs rats suffered increasingly from life shortening due to radiation-induced nonneoplastic causes and so had less time in which to develop tumors. When adjusted for these competing causes of death, the hazard function for the excess risk of developing pulmonary tumors was approximately linearly related to dose throughout the range of doses studied. This suggests that some previously reported high-dose ''reductions'' in radiogenic tumor-induction rates may chiefly have involved the killing of rats rather than the killing of precursor cells. Rats exposed to radon and then to six months of inhalation of tobacco smoke had a four times greater age-specific prevalence of pulmonary tumors than rats exposed to an identical radon dose either alone or preceded by tobacco smoke inhalation. This suggests that tobacco smoke may accelerate the carcinogenic process by acting as a promoter of radiation-induced somatic damage. These data suggest that, for assessing human risk from exposure to radon, the linear model should be assumed, but that the WLM is not on its own an adequate index of carcinogenic insult. 7 refs., 2 figs., 4 tabs

  6. Measurement of absorbed doses near interfaces, and dose mapping using gas chromic dosimetry media. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Rehim, F; Said, F I.A.; Abdel-Fattah, A A [National Centre for Radiation Research and Technology, Atomic Energy Athority, P.O.Box 29 Nasr City, Cairo (Egypt)

    1996-03-01

    Gas chromic dosimetry media is a thin-coated film which has advantages for high-dose radiation dosimetry, and produces high-resolution radiation image for gamma radiation. Therefore, these films were calibrated for the dose range 0.1-50 kGy in terms of increase in absorbance at 600 nm, 400 nm; increase in the area of the absorption spectra in the ranges 395-405 nm and 320-450 nm wave length as a function of absorbed dose in water. The calibrated films were used for measurement of absorbed doses close to metal interface, and dose mapping of the radiation field inside product box during a run for sterilizing surgical gloves at the mega-gamma irradiation facility.7 figs.

  7. Q2 anti Q2 states with relatively narrow widths

    International Nuclear Information System (INIS)

    Ono, Seiji.

    1978-09-01

    Using the mass formulas which correctly predict the mass of mesons and baryons the mass of diquark states is computed. From this mass spectrum the existance of the observed narrow baryonia and wide baryonia can be naturally understood. Other relatively narrow Q 2 anti Q 2 states are predicted to exist. (orig.) [de

  8. The dose-response relationship between cumulative lifting load and lumbar disk degeneration based on magnetic resonance imaging findings.

    Science.gov (United States)

    Hung, Yu-Ju; Shih, Tiffany T-F; Chen, Bang-Bin; Hwang, Yaw-Huei; Ma, Li-Ping; Huang, Wen-Chuan; Liou, Saou-Hsing; Ho, Ing-Kang; Guo, Yue L

    2014-11-01

    Lumbar disk degeneration (LDD) has been related to heavy physical loading. However, the quantification of the exposure has been controversial, and the dose-response relationship with the LDD has not been established. The purpose of this study was to investigate the dose-response relationship between lifetime cumulative lifting load and LDD. This was a cross-sectional study. Every participant received assessments with a questionnaire, magnetic resonance imaging (MRI) of the lumbar spine, and estimation of lumbar disk compression load. The MRI assessments included assessment of disk dehydration, annulus tear, disk height narrowing, bulging, protrusion, extrusion, sequestration, degenerative and spondylolytic spondylolisthesis, foramina narrowing, and nerve root compression on each lumbar disk level. The compression load was predicted using a biomechanical software system. A total of 553 participants were recruited in this study and categorized into tertiles by cumulative lifting load (ie, lifting load. The best dose-response relationships were found at the L5-S1 disk level, in which high cumulative lifting load was associated with elevated odds ratios of 2.5 (95% confidence interval [95% CI]=1.5, 4.1) for dehydration and 4.1 (95% CI=1.9, 10.1) for disk height narrowing compared with low lifting load. Participants exposed to intermediate lifting load had an increased odds ratio of 2.1 (95% CI=1.3, 3.3) for bulging compared with low lifting load. The tests for trend were significant. There is no "gold standard" assessment tool for measuring the lumbar compression load. The results suggest a dose-response relationship between cumulative lifting load and LDD. © 2014 American Physical Therapy Association.

  9. Influence of the narrow {111} planes on axial and planar ion channeling.

    Science.gov (United States)

    Motapothula, M; Dang, Z Y; Venkatesan, T; Breese, M B H; Rana, M A; Osman, A

    2012-05-11

    We report channeling patterns where clearly resolved effects of the narrow {111} planes are observed in axial and planar alignments for 2 MeV protons passing through a 55 nm [001] silicon membrane. At certain axes, such as and , the offset in atomic rows forming the narrow {111} planes results in shielding from the large potential at the wide {111} planes, producing a region of shallow, asymmetric potential from which axial channeling patterns have no plane of symmetry. At small tilts from such axes, different behavior is observed from the wide and narrow {111} planes. At planar alignment, distinctive channeling effects due to the narrow planes are observed. As a consequence of the shallow potential well at the narrow planes, incident protons suffer dechanneled trajectories which are excluded from channeling within the wide planes, resulting in an anomalously large scattered beam at {111} alignment.

  10. Resolving DNA at Efficiencies of More than A Million Plates per Meter Using Bare Narrow Open Capillary without Sieving Matrix

    OpenAIRE

    Zhu, Zaifang; Liu, Lei; Wang, Wei; Lu, Joann J.; Wang, Xiayan; Liu, Shaorong

    2013-01-01

    We report a novel approach for effectively separating DNA molecules in free solution. The method uses a bare narrow open capillary without any sieving matrices to resolve a wide size-range of DNA fragments at efficiencies of more than a million plates per meter routinely.

  11. Radiobiological aspects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation

    International Nuclear Information System (INIS)

    Turesson, I.

    1990-01-01

    The biological effects of continuous low dose-rate irradiation and fractionated high dose-rate irradiation in interstitial and intracavitary radiotherapy and total body irradiation are discussed in terms of dose-rate fractionation sensitivity for various tissues. A scaling between dose-rate and fraction size was established for acute and late normal-tissue effects which can serve as a guideline for local treatment in the range of dose rates between 0.02 and 0.005 Gy/min and fraction sizes between 8.5 and 2.5 Gy. This is valid provided cell-cycle progression and proliferation can be ignored. Assuming that the acute and late tissue responses are characterized by α/β values of about 10 and 3 Gy and a mono-exponential repair half-time of about 3 h, the same total doses given with either of the two methods are approximately equivalent. The equivalence for acute and late non-hemopoietic normal tissue damage is 0.02 Gy/min and 8.5 Gy per fraction; 0.01 Gy/min and 5.5 Gy per fraction; and 0.005 Gy/min and 2.5Gy per fraction. A very low dose rate, below 0.005 Gy/min, is thus necessary to simulate high dose-rate radiotherapy with fraction sizes of about 2Gy. The scaling factor is, however, dependent on the repair half-time of the tissue. A review of published data on dose-rate effects for normal tissue response showed a significantly stronger dose-rate dependence for late than for acute effects below 0.02 Gy/min. There was no significant difference in dose-rate dependence between various acute non-hemopoietic effects or between various late effects. The consistent dose-rate dependence, which justifies the use of a general scaling factor between fraction size and dose rate, contrasts with the wide range of values for repair half-time calculated for various normal-tissue effects. This indicates that the model currently used for repair kinetics is not satisfactory. There are also few experimental data in the clinical dose-rate range, below 0.02 Gy/min. It is therefore

  12. Narrowing the Gap in Outcomes: Early Years (0-5 Years)

    Science.gov (United States)

    Springate, Ian; Atkinson, Mary; Straw, Suzanne; Lamont, Emily; Grayson, Hilary

    2008-01-01

    This report was commissioned by the Local Government Association (LGA) to inform the Department for Children, Schools and Families (DCSF) and LGA work on "Narrowing the Gap." It focuses on early years' provision and presents findings from a review of the best evidence on narrowing the gap in outcomes across the five Every Child Matters…

  13. Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels

    International Nuclear Information System (INIS)

    Islam, M.S.; Hino, Ryutaro; Haga, Katsuhiro; Sudo, Yukio; Monde, Masanori.

    1997-03-01

    Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m 2 generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher heat flux up to 12 MW/m 2 could be removed from the rib-roughened surface without flow boiling which induces flow instability; but pressure drop reaches about 1.8 MPa. Correlations obtained by air-flow experiments have showed lower heat transfer performance with the water-flow conditions. The experimental apparatus was proposed for further investigation on heat transfer augmentation in very narrow channels under water-flow conditions. This report presents the evaluation results and an outline of the test apparatus. (author)

  14. Comparative Study of the Gross Interpretation of Phototesting and Objective Measurement with Using a Spectrophotometer for Patients with Psoriasis and Vitiligo Treated with Narrow-band UVB.

    Science.gov (United States)

    Choi, Kyu-Won; Kim, Ki-Ho; Kim, Young-Hun

    2009-05-01

    Determination of the minimal erythema dose (MED) is important for developing a phototherapy protocol and to diagnosis photosensitivity disorders. But obtaining a precise and reproducible MED is quite difficult because a phototest for erythema is based on subjective assessment. The objective of our study was to compare the gross interpretation of a phototest and the objective measurement using a spectrophotometer for determining the parameters of cutaneous narrow-band UVB (NBUVB) therapy. A total of 14 psoriasis and 10 vitiligo patients who receiving NBUVB phototherapy with skin types III and IV were selected for this study. To perform phototesting, ten sites on the skin of the back were vertically exposed to a series of 10 NBUVB doses among 14 doses between 340 and 1,400 mJ/cm(2). We interpreted the gross findings of erythema and measured the L*a*b* values with using a spectrophotometer at each phototest spot and at the control skin. Also, we evaluate the relationship between the gross presentation and the spectrophotometric analysis by delta E for the assessment of the minimal perceptible erythema (MPE) and MED. For all the subjects, the MEDs were measured in the 490~1,000 mJ/cm(2) range. The average of the colorimetric values for the control skin were L*: 64.8, a*: 7.9 and b*: 19.8. Among them, the L* value and MED value were shown to be inversely correlated, and as the L* value was decreased, the MED was increased. For the MPE, the delta E, which was the color difference of the normal skin and the phototest area, was within the range of 1.5~3.0 in 17 of the 21 patients, and 4 patients were within the range of 1.0~1.5. For the MED, among the 21 patients, the delta E of 17 patients was within the range of 3.0~6.0, and 4 patients were within the range of 6.0~12.0. A spectrophotometer enables UV erythema to be assessed objectively and quantitatively, and this can compensate for the disadvantages of subjective gross interpretation when determining the MED. Delta E is

  15. Narrow-width mechanism of a=5 Ξ-state

    International Nuclear Information System (INIS)

    Kumagai-Fuse, I.; Akaishi, Y.

    1995-04-01

    Narrow-width mechanism of ≡ 5 H is discussed by calculating conversion widths to all its possible decay channels. Since the conversion processes have small reaction Q values, the three- and four- body decays are strongly suppressed owing to small phase volumes available. Decay widths to the two-body channels are significantly reduced by the distortion of emitted-particle waves. This mechanism brings about a narrow width of ≡ 5 H. The total width is estimated to be 0.87 MeV, in which the largest contribution comes from the decay into the Λ 4 H * +Λ channel. (author)

  16. Narrow absorption lines complex I: one form of broad absorption line

    Science.gov (United States)

    Lu, Wei-Jian; Lin, Ying-Ru

    2018-03-01

    We discover that some of the broad absorption lines (BALs) are actually a complex of narrow absorption lines (NALs). As a pilot study of this type of BAL, we show this discovery through a typical example in this paper. Utilizing the two-epoch observations of J002710.06-094435.3 (hereafter J0027-0944) from the Sloan Digital Sky Survey (SDSS), we find that each of the C IV and Si IV BAL troughs contains at least four NAL doublets. By resolving the Si IV BAL into multiple NALs, we present the following main results and conclusions. First, all these NALs show coordinated variations between the two-epoch SDSS observations, suggesting that they all originate in the quasar outflow, and that their variations are due to global changes in the ionization condition of the absorbing gas. Secondly, a BAL consisting of a number of NAL components indicates that this type of BAL is basically the same as the intrinsic NAL, which tends to support the inclination model rather than the evolution model. Thirdly, although both the C IV and Si IV BALs originate from the same clumpy substructures of the outflow, they show different profile shapes: multiple absorption troughs for the Si IV BAL in a wider velocity range, while P-Cygni for the C IV BAL in a narrower velocity range. This can be interpreted by the substantial differences in fine structure and oscillator strength between the Si IVλλ1393, 1402 and C IVλλ1548, 1551 doublets. Based on the above conclusions, we consider that the decomposition of a BAL into NALs can serve as a way to resolve the clumpy structure for outflows, and it can be used to learn more about characteristics of the clumpy structure and to test the outflow model, when utilizing high-resolution spectra and photoionization model.

  17. Comparison of low dose with standard dose abdominal/pelvic multidetector CT in patients with stage 1 testicular cancer under surveillance

    Energy Technology Data Exchange (ETDEWEB)

    O' Malley, Martin E. [Joint Department of Medical Imaging, Toronto, ON (Canada); Chung, Peter; Warde, Padraig [Princess Margaret Hospital, Department of Radiation Oncology, Toronto, ON (Canada); Haider, Masoom; Jhaveri, Kartik; Khalili, Korosh [Princess Margaret Hospital, Joint Department of Medical Imaging, Toronto, ON (Canada); Jang, Hyun-Jung [Toronto General Hospital, Joint Department of Medical Imaging, Toronto, ON (Canada); Panzarella, Tony [Princess Margaret Hospital, Department of Biostatistics, Toronto, ON (Canada)

    2010-07-15

    To compare the image quality and acceptability of a low dose with those of standard dose abdominal/pelvic multidetector CT in patients with stage 1 testicular cancer managed by surveillance. One hundred patients (median age 31 years; range 19-83 years), 79 with seminoma and 21 with non-seminoma, underwent abdominal/pelvic imaging with low and standard dose protocols on 64-slice multidetector CT. Three reviewers independently evaluated images for noise and diagnostic quality on a 5-point scale and for diagnostic acceptability. On average, each reader scored noise and diagnostic quality of standard dose images significantly better than corresponding low dose images (p < 0.0001). One reader found all CT examinations acceptable; two readers each found 1/100 (1%) low dose examinations unacceptable. Median and mean dose-length product for low and standard dose protocols were 416.0 and 452.2 (range 122.9-913.4) and 931.9 and 999.8 (range 283.8-1,987.7) mGy cm, respectively. The low dose protocol provided diagnostically acceptable images for at least 99% of patients and achieved mean dose reduction of 55% compared with the standard dose protocol. (orig.)

  18. Experimental studies of x-ray laser spectral profiles: Observation of gain narrowing and saturation behavior

    International Nuclear Information System (INIS)

    Koch, J.A.; MacGowan, B.J.; Da Silva, L.B.; Matthews, D.L.; Mrowka, S.; Underwood, J.H.; Batson, P.J.

    1992-01-01

    We discuss our recent measurements of the spectral width of the 206.38 Angstrom x-ray laser transition in Ne-like Se. These measurements used a high-resolution grating spectrometer and were performed over a wide range of laser amplifier lengths. The data have enabled us to extrapolate the intrinsic line width and to observe the effects of gain-narrowing and saturation on the line profile. We find an intrinsic width which is 1.4 times the Doppler width, we observe gain-narrowing in intermediate length amplifiers, and we observe no re-broadening in long, saturated amplifiers. These results suggest that collisional line-broadening has a significant effect on the line profile and saturation behavior of this laser. We discuss modeling we have performed in order to simulate the experimental data, and we discuss future experimental and theoretical efforts we believe are necessary in order to understand line broadening and line transfer issues in x-ray laser plasmas

  19. The protective effect of a beta 2 agonist against excessive airway narrowing in response to bronchoconstrictor stimuli in asthma and chronic obstructive lung disease.

    Science.gov (United States)

    Bel, E. H.; Zwinderman, A. H.; Timmers, M. C.; Dijkman, J. H.; Sterk, P. J.

    1991-01-01

    Beta 2 agonists reduce airway hypersensitivity to bronchoconstrictor stimuli acutely in patients with asthma and chronic obstructive lung disease. To determine whether these drugs also protect against excessive airway narrowing, the effect of inhaled salbutamol on the position and shape of the dose-response curves for histamine or methacholine was investigated in 12 patients with asthma and 11 with chronic obstructive lung disease. After pretreatment with salbutamol (200 or 400 micrograms) or placebo in a double blind manner dose-response curves for inhaled histamine and methacholine were obtained by a standard method on six days in random order. Airway sensitivity was defined as the concentration of histamine or methacholine causing a 20% fall in FEV1 (PC20). A maximal response plateau on the log dose-response curve was considered to be present if two or more data points for FEV1 fell within a 5% response range. In the absence of a plateau, the test was continued until a predetermined level of severe bronchoconstriction was reached. Salbutamol caused an acute increase in FEV1 (mean increase 11.5% predicted in asthma, 7.2% in chronic obstructive lung disease), and increase in PC20 (mean 15 fold in asthma, fivefold in chronic obstructive lung disease), and an increase in the slope of the dose-response curves in both groups. In subjects in whom a plateau of FEV1 response could be measured salbutamol did not change the level of the plateau. In subjects without a plateau salbutamol did not lead to the development of a plateau, despite achieving a median FEV1 of 44% predicted in asthma and 39% in chronic obstructive lung disease. These results show that, although beta 2 agonists acutely reduce the airway response to a given strength of bronchoconstrictor stimulus, they do not protect against excessive airflow obstruction if there is exposure to relatively strong stimuli. This, together with the steepening of the dose-response curve, could be a disadvantage of beta 2

  20. Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    Science.gov (United States)

    Campos, L. T.; Leite, S. P.; de Almeida, C. E. V.; Magalhães, L. A. G.

    2018-03-01

    Stereotactic radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. To guarantee a high quality standard, a comprehensive Quality Assurance programme is extremely important to ensure that the measured dose is consistent with the tolerance considered to improve treatment quality. The Radiological Science Laboratory operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy in known geometry and the dosimetric conditions of the TPS. The programme works in such a way those thermoluminescence dosimeters, consisting of LiF chips, are sent to the centre where they are to be irradiated to a certain dose. The TLD are then returned, where they are evaluated and the absorbed dose is obtained from TLDs readings. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data.

  1. Granular bamboo-derived activated carbon for high CO(2) adsorption: the dominant role of narrow micropores.

    Science.gov (United States)

    Wei, Haoran; Deng, Shubo; Hu, Bingyin; Chen, Zhenhe; Wang, Bin; Huang, Jun; Yu, Gang

    2012-12-01

    Cost-effective biomass-derived activated carbons with a high CO(2) adsorption capacity are attractive for carbon capture. Bamboo was found to be a suitable precursor for activated carbon preparation through KOH activation. The bamboo size in the range of 10-200 mesh had little effect on CO(2) adsorption, whereas the KOH/C mass ratio and activation temperature had a significant impact on CO(2) adsorption. The bamboo-derived activated carbon had a high adsorption capacity and excellent selectivity for CO(2) , and also the adsorption process was highly reversible. The adsorbed amount of CO(2) on the granular activated carbon was up to 7.0 mmol g(-1) at 273 K and 1 bar, which was higher than almost all carbon materials. The pore characteristics of activated carbons responsible for high CO(2) adsorption were fully investigated. Based on the analysis of narrow micropore size distribution of several activated carbons prepared under different conditions, a more accurate micropore range contributing to CO(2) adsorption was proposed. The volume of micropores in the range of 0.33-0.82 nm had a good linear relationship with CO(2) adsorption at 273 K and 1 bar, and the narrow micropores of about 0.55 nm produced the major contribution, which could be used to evaluate CO(2) adsorption on activated carbons. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Dose-response met-RANTES treatment of experimental periodontitis: a narrow edge between the disease severity attenuation and infection control.

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Repeke

    Full Text Available Chemokines and chemokine receptors have been implicated in the selective migration of leukocyte subsets to periodontal tissues, which consequently influences the disease outcome. Among these chemoattractants, the chemokines CCL3, CCL4 and CCL5 and its receptors, CCR1 and CCR5, have been associated with increased disease severity in mice and humans. Therefore, in this study we investigated the modulation of experimental periodontitis outcome by the treatment with a specific antagonist of CCR1 and 5 receptors, called met-RANTES. C57Bl/6 mice was orally infected with Aggregatibacter actinomycetemcomitans and treated with 0.05, 0.1, 0.5, 1.5 and 5 mg doses of met-RANTES on alternate days, and evaluated by morphometric, cellular, enzymatic and molecular methods. At 0.5 mg up to 5 mg doses, a strong reduction in the alveolar bone loss and inflammatory cell migration were observed. Interestingly, 5 mg dose treatment resulted in the maximum inhibition of inflammatory cell migration, but resulted in a similar inhibition of bone loss when compared with the lower doses, and also resulted in increased bacterial load and CRP response. When 0.5 and 5 mg therapy regimens were compared it was observed that both therapeutic protocols were able to downregulate the levels of pro-inflammatory, Th1-type and osteoclastogenic cytokines, and CD3+ and F4/80+ cells migration to periodontal tissues, but the high dose modulates host response in a more pronounced and unspecific and excessive way, interfering also with the production of antimicrobial mediators such as MPO, iNOS and IgG, and with GR1+ and CD19+ cells migration. Our results demonstrate a thin line between beneficial immunoregulation and impaired host defense during experimental periodontitis, and the determination of the exact equilibrium point is mandatory for the improvement of immune-targeted therapy of periodontitis.

  3. Investigation of polymer composite for high dose dosimetry

    International Nuclear Information System (INIS)

    Pereira, E.L.M.; Batista, A.S.M.; Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H.

    2017-01-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO 2 ) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm -1 and 1730 cm -1 can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm -1 and 1730 cm -1 whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  4. Oscillatory Dynamics Underlying Perceptual Narrowing of Native Phoneme Mapping from 6 to 12 Months of Age.

    Science.gov (United States)

    Ortiz-Mantilla, Silvia; Hämäläinen, Jarmo A; Realpe-Bonilla, Teresa; Benasich, April A

    2016-11-30

    During the first months of life, human infants process phonemic elements from all languages similarly. However, by 12 months of age, as language-specific phonemic maps are established, infants respond preferentially to their native language. This process, known as perceptual narrowing, supports neural representation and thus efficient processing of the distinctive phonemes within the sound environment. Although oscillatory mechanisms underlying processing of native and non-native phonemic contrasts were recently delineated in 6-month-old infants, the maturational trajectory of these mechanisms remained unclear. A group of typically developing infants born into monolingual English families, were followed from 6 to 12 months and presented with English and Spanish syllable contrasts varying in voice-onset time. Brain responses were recorded with high-density electroencephalogram, and sources of event-related potential generators identified at right and left auditory cortices at 6 and 12 months and also at frontal cortex at 6 months. Time-frequency analyses conducted at source level found variations in both θ and γ ranges across age. Compared with 6-month-olds, 12-month-olds' responses to native phonemes showed smaller and faster phase synchronization and less spectral power in the θ range, and increases in left phase synchrony as well as induced high-γ activity in both frontal and left auditory sources. These results demonstrate that infants become more automatized and efficient in processing their native language as they approach 12 months of age via the interplay between θ and γ oscillations. We suggest that, while θ oscillations support syllable processing, γ oscillations underlie phonemic perceptual narrowing, progressively favoring mapping of native over non-native language across the first year of life. During early language acquisition, typically developing infants gradually construct phonemic maps of their native language in auditory cortex. It is well

  5. Computerized clinical decision support systems for therapeutic drug monitoring and dosing: A decision-maker-researcher partnership systematic review

    Directory of Open Access Journals (Sweden)

    Weise-Kelly Lorraine

    2011-08-01

    Full Text Available Abstract Background Some drugs have a narrow therapeutic range and require monitoring and dose adjustments to optimize their efficacy and safety. Computerized clinical decision support systems (CCDSSs may improve the net benefit of these drugs. The objective of this review was to determine if CCDSSs improve processes of care or patient outcomes for therapeutic drug monitoring and dosing. Methods We conducted a decision-maker-researcher partnership systematic review. Studies from our previous review were included, and new studies were sought until January 2010 in MEDLINE, EMBASE, Evidence-Based Medicine Reviews, and Inspec databases. Randomized controlled trials assessing the effect of a CCDSS on process of care or patient outcomes were selected by pairs of independent reviewers. A study was considered to have a positive effect (i.e., CCDSS showed improvement if at least 50% of the relevant study outcomes were statistically significantly positive. Results Thirty-three randomized controlled trials were identified, assessing the effect of a CCDSS on management of vitamin K antagonists (14, insulin (6, theophylline/aminophylline (4, aminoglycosides (3, digoxin (2, lidocaine (1, or as part of a multifaceted approach (3. Cluster randomization was rarely used (18% and CCDSSs were usually stand-alone systems (76% primarily used by physicians (85%. Overall, 18 of 30 studies (60% showed an improvement in the process of care and 4 of 19 (21% an improvement in patient outcomes. All evaluable studies assessing insulin dosing for glycaemic control showed an improvement. In meta-analysis, CCDSSs for vitamin K antagonist dosing significantly improved time in therapeutic range. Conclusions CCDSSs have potential for improving process of care for therapeutic drug monitoring and dosing, specifically insulin and vitamin K antagonist dosing. However, studies were small and generally of modest quality, and effects on patient outcomes were uncertain, with no convincing

  6. Calculation of dose conversion factors for doses in the fingernails to organ doses at external gamma irradiation in air

    International Nuclear Information System (INIS)

    Khailov, A.M.; Ivannikov, A.I.; Skvortsov, V.G.; Stepanenko, V.F.; Orlenko, S.P.; Flood, A.B.; Williams, B.B.; Swartz, H.M.

    2015-01-01

    Absorbed doses to fingernails and organs were calculated for a set of homogenous external gamma-ray irradiation geometries in air. The doses were obtained by stochastic modeling of the ionizing particle transport (Monte Carlo method) for a mathematical human phantom with arms and hands placed loosely along the sides of the body. The resulting dose conversion factors for absorbed doses in fingernails can be used to assess the dose distribution and magnitude in practical dose reconstruction problems. For purposes of estimating dose in a large population exposed to radiation in order to triage people for treatment of acute radiation syndrome, the calculated data for a range of energies having a width of from 0.05 to 3.5 MeV were used to convert absorbed doses in fingernails to corresponding doses in organs and the whole body as well as the effective dose. Doses were assessed based on assumed rates of radioactive fallout at different time periods following a nuclear explosion. - Highlights: • Elemental composition and density of nails were determined. • MIRD-type mathematical human phantom with arms and hands was created. • Organ doses and doses to nails were calculated for external photon exposure in air. • Effective dose and nail doses values are close for rotational and soil surface exposures.

  7. Nasal base narrowing of the caucasian nose through the cerclage technique

    Directory of Open Access Journals (Sweden)

    Mocellin, Marcos

    2010-06-01

    Full Text Available Introduction: Several techniques can be performed to reduce the nasal base (narrowing, as skin resection vestibular columellar skin resection, resection of skin in elliptical lip narinary, sloughing of skin and advancements (VY technique of Bernstein and the use of cerclage sutures in the nasal base. Objective: To evaluate the technique of cerclage performed in the nasal base, through endonasal rhinoplasty without delivery of basic technique, in the Caucasian nose, reducing the distance inter-alar flare and correcting the wing with consequent improvement in nasal harmony in the whole face. Methods: A retrospective analysis by analysis of clinical documents and photos of 43 patients in whom cerclage was made of the nasal base by resecting skin ellipse in the region of the vestibule and the nasal base (modified technique of Weir using colorless mononylon® 4 "0" with a straight cutting needle. The study was conducted in 2008 and 2009 at Hospital of Paraná Institute of Otolaryngology - IPO in Curitiba, Parana - Brazil. Patients had a follow up ranging 7-12 months. Results: In 100% of cases was achieved an improvement in nasal harmony, by decreasing the inter-alar distance. Conclusion: The encircling with minimal resection of vestibular skin and the nasal base is an effective method for the narrowing of the nasal base in the Caucasian nose, with predictable results and easy to perform.

  8. Dose and Dose-Rate Effectiveness Factor (DDREF); Der Dosis- und Dosisleistungs-Effektivitaetsfaktor (DDREF)

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, Joachim [Fachhochschule Giessen-Friedberg, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2016-08-01

    For practical radiation protection purposes it is supposed that stochastic radiation effects a determined by a proportional dose relation (LNT). Radiobiological and radiation epidemiological studies indicated that in the low dose range a dependence on dose rates might exist. This would trigger an overestimation of radiation risks based on the LNT model. OCRP had recommended a concept to combine all effects in a single factor DDREF (dose and dose-Rate effectiveness factor). There is still too low information on cellular mechanisms of low dose irradiation including possible repair and other processes. The Strahlenschutzkommission cannot identify a sufficient scientific justification for DDREF and recommends an adaption to the actual state of science.

  9. Correlation of patient maximum skin doses in cardiac procedures with various dose indicators

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.; Werduch, A.; Religa, W.

    2008-01-01

    In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used for patient dosimetry purposes in clinical practice. This study aimed at relating those dose indicators with doses ascribed to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). The study was performed in two different facilities for two most common cardiac procedures coronary angiography (CA) and percutaneous coronary interventions (PCI). For CA procedures, the registered values of fluoroscopy time, total DAP and MSD were in the range (0.7-27.3) min, (16-317) Gy cm 2 and (43-1507) mGy, respectively, and for interventions, accordingly (2.1-43.6) min, (17-425) Gy cm 2 , (71-1555) mGy. Moreover, for CA procedures, CD and EFD were in the ranges (295-4689) mGy and (121-1768) mGy and for PCI (267-6524) mGy and (68-2279) mGy, respectively. No general and satisfactory correlation was found for safe estimation of MSD. However, results show that the best dose indicator which might serve for rough, preliminary estimation is DAP value. In the study, the appropriate trigger levels were proposed for both facilities. (authors)

  10. Narrow duplicated internal auditory canal: radiological findings and review of the literature

    International Nuclear Information System (INIS)

    Demir, Oezguen Ilhan; Cakmakci, Handan; Men, Sueleyman; Erdag, Taner Kemal

    2005-01-01

    Narrow duplicated internal auditory canal (IAC) is a rare malformation of the temporal bone that is associated with ipsilateral congenital sensorineural hearing loss. This may be an isolated finding or a part of a syndrome. Radiological examination should demonstrate aplasia or hypoplasia of the neural components of the narrow IAC, to guide the surgical approach. We report a 7-year-old boy with Klippel-Feil syndrome with a narrow double IAC with no sensorineural hearing loss but with conductive hearing loss. In this patient, the IAC consisted of two separate narrow bony canals clearly seen on 3D temporal bone CT and one nerve that was delineated on MRI. The contralateral external auditory canal was stenotic and the ossicles were dysplastic. (orig.)

  11. Upgrades of DARWIN, a dose and spectrum monitoring system applicable to various types of radiation over wide energy ranges

    Science.gov (United States)

    Sato, Tatsuhiko; Satoh, Daiki; Endo, Akira; Shigyo, Nobuhiro; Watanabe, Fusao; Sakurai, Hiroki; Arai, Yoichi

    2011-05-01

    A dose and spectrum monitoring system applicable to neutrons, photons and muons over wide ranges of energy, designated as DARWIN, has been developed for radiological protection in high-energy accelerator facilities. DARWIN consists of a phoswitch-type scintillation detector, a data-acquisition (DAQ) module for digital waveform analysis, and a personal computer equipped with a graphical-user-interface (GUI) program for controlling the system. The system was recently upgraded by introducing an original DAQ module based on a field programmable gate array, FPGA, and also by adding a function for estimating neutron and photon spectra based on an unfolding technique without requiring any specific scientific background of the user. The performance of the upgraded DARWIN was examined in various radiation fields, including an operational field in J-PARC. The experiments revealed that the dose rates and spectra measured by the upgraded DARWIN are quite reasonable, even in radiation fields with peak structures in terms of both spectrum and time variation. These results clearly demonstrate the usefulness of DARWIN for improving radiation safety in high-energy accelerator facilities.

  12. Upgrades of DARWIN, a dose and spectrum monitoring system applicable to various types of radiation over wide energy ranges

    International Nuclear Information System (INIS)

    Sato, Tatsuhiko; Satoh, Daiki; Endo, Akira; Shigyo, Nobuhiro; Watanabe, Fusao; Sakurai, Hiroki; Arai, Yoichi

    2011-01-01

    A dose and spectrum monitoring system applicable to neutrons, photons and muons over wide ranges of energy, designated as DARWIN, has been developed for radiological protection in high-energy accelerator facilities. DARWIN consists of a phoswitch-type scintillation detector, a data-acquisition (DAQ) module for digital waveform analysis, and a personal computer equipped with a graphical-user-interface (GUI) program for controlling the system. The system was recently upgraded by introducing an original DAQ module based on a field programmable gate array, FPGA, and also by adding a function for estimating neutron and photon spectra based on an unfolding technique without requiring any specific scientific background of the user. The performance of the upgraded DARWIN was examined in various radiation fields, including an operational field in J-PARC. The experiments revealed that the dose rates and spectra measured by the upgraded DARWIN are quite reasonable, even in radiation fields with peak structures in terms of both spectrum and time variation. These results clearly demonstrate the usefulness of DARWIN for improving radiation safety in high-energy accelerator facilities.

  13. NMR imaging of solids with multiple-pulse line narrowing and radiofrequency gradients

    International Nuclear Information System (INIS)

    Werner, M.H.

    1993-01-01

    The usual methods of magnetic resonance imaging fail in rigid solids due to the line-shape contributions of dipolar coupling, chemical shift dispersion and anisotropy, and bulk magnetic susceptibility. This dissertation presents a new method of solid-stage imaging by nuclear magnetic resonance which averages away these contributions with multiple-pulse line-narrowing and encodes spatial information with pulsed radiofrequency field gradients. This method is closely related to simultaneously developed methods utilizing pulsed DC gradients, and offers similar improvements in sensitivity and resolution. The advantage of rf gradients is that they can be rapidly switched without inducing eddy currents in the probe or the magnet. In addition, the phases and amplitudes of the rf gradients can be switched by equipment which is already part of an NMR spectrometer capable of solid-state spectroscopy. The line-narrowing and gradient pulses originate in separate rf circuits tuned to the same frequency. Interactions between the circuits have been minimized by a method of active Q-switching which employs PIN diodes in the matching networks of these circuits. Both one- and two-dimensional images are presented. The latter are obtained by a novel method in which the two dimensions of imaging transverse to the static magnetic field are encoded by two orthogonal components of a single rf gradient. A π/2 phase shift of the rf phase relative to that of the line-narrowing pulses selects one component or the other. This arrangement allows the solid-state analogs of versatile imaging sequences based on Fourier imaging and eliminates the need for sample rotation and back-projection methods. Coherent averaging theory is used to analyze this imaging technique and exact numerical simulations on several coupled spins are discussed. These lend insight to the residual linewidth and its dependence on pixel position as well as to the range of applicability of this technique

  14. An empirical model of diagnostic x-ray attenuation under narrow-beam geometry

    International Nuclear Information System (INIS)

    Mathieu, Kelsey B.; Kappadath, S. Cheenu; White, R. Allen; Atkinson, E. Neely; Cody, Dianna D.

    2011-01-01

    Purpose: The purpose of this study was to develop and validate a mathematical model to describe narrow-beam attenuation of kilovoltage x-ray beams for the intended applications of half-value layer (HVL) and quarter-value layer (QVL) estimations, patient organ shielding, and computer modeling. Methods: An empirical model, which uses the Lambert W function and represents a generalized Lambert-Beer law, was developed. To validate this model, transmission of diagnostic energy x-ray beams was measured over a wide range of attenuator thicknesses [0.49-33.03 mm Al on a computed tomography (CT) scanner, 0.09-1.93 mm Al on two mammography systems, and 0.1-0.45 mm Cu and 0.49-14.87 mm Al using general radiography]. Exposure measurements were acquired under narrow-beam geometry using standard methods, including the appropriate ionization chamber, for each radiographic system. Nonlinear regression was used to find the best-fit curve of the proposed Lambert W model to each measured transmission versus attenuator thickness data set. In addition to validating the Lambert W model, we also assessed the performance of two-point Lambert W interpolation compared to traditional methods for estimating the HVL and QVL [i.e., semilogarithmic (exponential) and linear interpolation]. Results: The Lambert W model was validated for modeling attenuation versus attenuator thickness with respect to the data collected in this study (R 2 > 0.99). Furthermore, Lambert W interpolation was more accurate and less sensitive to the choice of interpolation points used to estimate the HVL and/or QVL than the traditional methods of semilogarithmic and linear interpolation. Conclusions: The proposed Lambert W model accurately describes attenuation of both monoenergetic radiation and (kilovoltage) polyenergetic beams (under narrow-beam geometry).

  15. An empirical model of diagnostic x-ray attenuation under narrow-beam geometry.

    Science.gov (United States)

    Mathieu, Kelsey B; Kappadath, S Cheenu; White, R Allen; Atkinson, E Neely; Cody, Dianna D

    2011-08-01

    The purpose of this study was to develop and validate a mathematical model to describe narrow-beam attenuation of kilovoltage x-ray beams for the intended applications of half-value layer (HVL) and quarter-value layer (QVL) estimations, patient organ shielding, and computer modeling. An empirical model, which uses the Lambert W function and represents a generalized Lambert-Beer law, was developed. To validate this model, transmission of diagnostic energy x-ray beams was measured over a wide range of attenuator thicknesses [0.49-33.03 mm Al on a computed tomography (CT) scanner, 0.09-1.93 mm Al on two mammography systems, and 0.1-0.45 mm Cu and 0.49-14.87 mm Al using general radiography]. Exposure measurements were acquired under narrow-beam geometry using standard methods, including the appropriate ionization chamber, for each radiographic system. Nonlinear regression was used to find the best-fit curve of the proposed Lambert W model to each measured transmission versus attenuator thickness data set. In addition to validating the Lambert W model, we also assessed the performance of two-point Lambert W interpolation compared to traditional methods for estimating the HVL and QVL [i.e., semi-logarithmic (exponential) and linear interpolation]. The Lambert W model was validated for modeling attenuation versus attenuator thickness with respect to the data collected in this study (R2 > 0.99). Furthermore, Lambert W interpolation was more accurate and less sensitive to the choice of interpolation points used to estimate the HVL and/or QVL than the traditional methods of semilogarithmic and linear interpolation. The proposed Lambert W model accurately describes attenuation of both monoenergetic radiation and (kilovoltage) polyenergetic beams (under narrow-beam geometry).

  16. Expanding the dynamic measurement range for polymeric nanoparticle pH sensors

    DEFF Research Database (Denmark)

    Sun, Honghao; Almdal, Kristoffer; Andresen, Thomas Lars

    2011-01-01

    Conventional optical nanoparticle pH sensors that are designed for ratiometric measurements in cells have been based on utilizing one sensor fluorophore and one reference fluorophore in each nanoparticle, which results in a relatively narrow dynamic measurement range. This results in substantial...

  17. Ultra-narrow band perfect absorbers based on Fano resonance in MIM metamaterials

    Science.gov (United States)

    Zhang, Ming; Fang, Jiawen; Zhang, Fei; Chen, Junyan; Yu, Honglin

    2017-12-01

    Metallic nanostructures have attracted numerous attentions in the past decades due to their attractive plasmonic properties. Resonant plasmonic perfect absorbers have promising applications in a wide range of technologies including photothermal therapy, thermophotovoltaics, heat-assisted magnetic recording and biosensing. However, it remains to be a great challenge to achieve ultra-narrow band in near-infrared band with plasmonic materials due to the large optical losses in metals. In this letter, we introduced Fano resonance in MIM metamaterials composed of an asymmetry double elliptic cylinders (ADEC), which can achieve ultra-narrow band perfect absorbers. In theoretical calculations, we observed an ultranarrow band resonant absorption peak with the full width at half maximum (FWHM) of 8 nm and absorption amplitude exceeding 99% at 930 nm. Moreover, we demonstrate that the absorption increases with the increase of asymmetry and the absorption resonant wavelength can be tuned by changing the size and arrangement of the unit cell. The asymmetry metallic nanostructure also exhibit a higher refractive sensitivity as large as 503 nm/RIU with high figure of merit of 63, which is promising for high sensitive sensors. Results of this work are desirable for various potential applications in micro-technological structures such as biological sensors, narrowband emission, photodetectors and solar thermophotovoltaic (STPV) cells.

  18. Radiation dose distributions close to the shower axis calculated for high energy electron initiated electromagnetic showers in air

    International Nuclear Information System (INIS)

    Geer, S.; Gsponer, A.

    1983-01-01

    Absorbed radiation doses produced by 500, 1,000 and 10,000 MeV electron initiated electromagnetic showers in air have been calculated using a Monte Carlo program. The radial distributions of the absorbed dose near to the shower axis are found to be significantly narrower than predicted by simple analytical shower theory. For a 500 MeV, 10 kA, 100 ns electron beam pulse, the region in which the total dose is in excess of 1 krad and the dose rate in excess of 10 10 rad/s is a cigar-shaped envelope of radius 1 m and length 200 m. (orig.) [de

  19. 76 FR 60733 - Drawbridge Operation Regulations; Narrow Bay, Smith Point, NY

    Science.gov (United States)

    2011-09-30

    ... Operation Regulations; Narrow Bay, Smith Point, NY AGENCY: Coast Guard, DHS. ACTION: Notice of temporary... deviation from the regulation governing the operation of the Smith Point Bridge, 6.1, across Narrow Bay, between Smith Point and Fire Island, New York. The deviation is necessary to facilitate bridge...

  20. Further Simplification of the Simple Erosion Narrowing Score With Item Response Theory Methodology.

    Science.gov (United States)

    Oude Voshaar, Martijn A H; Schenk, Olga; Ten Klooster, Peter M; Vonkeman, Harald E; Bernelot Moens, Hein J; Boers, Maarten; van de Laar, Mart A F J

    2016-08-01

    To further simplify the simple erosion narrowing score (SENS) by removing scored areas that contribute the least to its measurement precision according to analysis based on item response theory (IRT) and to compare the measurement performance of the simplified version to the original. Baseline and 18-month data of the Combinatietherapie Bij Reumatoide Artritis (COBRA) trial were modeled using longitudinal IRT methodology. Measurement precision was evaluated across different levels of structural damage. SENS was further simplified by omitting the least reliably scored areas. Discriminant validity of SENS and its simplification were studied by comparing their ability to differentiate between the COBRA and sulfasalazine arms. Responsiveness was studied by comparing standardized change scores between versions. SENS data showed good fit to the IRT model. Carpal and feet joints contributed the least statistical information to both erosion and joint space narrowing scores. Omitting the joints of the foot reduced measurement precision for the erosion score in cases with below-average levels of structural damage (relative efficiency compared with the original version ranged 35-59%). Omitting the carpal joints had minimal effect on precision (relative efficiency range 77-88%). Responsiveness of a simplified SENS without carpal joints closely approximated the original version (i.e., all Δ standardized change scores were ≤0.06). Discriminant validity was also similar between versions for both the erosion score (relative efficiency = 97%) and the SENS total score (relative efficiency = 84%). Our results show that the carpal joints may be omitted from the SENS without notable repercussion for its measurement performance. © 2016, American College of Rheumatology.

  1. Spark PRM: Using RRTs within PRMs to efficiently explore narrow passages

    KAUST Repository

    Shi, Kensen; Denny, Jory; Amato, Nancy M.

    2014-01-01

    © 2014 IEEE. Probabilistic RoadMaps (PRMs) have been successful for many high-dimensional motion planning problems. However, they encounter difficulties when mapping narrow passages. While many PRM sampling methods have been proposed to increase the proportion of samples within narrow passages, such difficult planning areas still pose many challenges. We introduce a novel algorithm, Spark PRM, that sparks the growth of Rapidly-expanding Random Trees (RRTs) from narrow passage samples generated by a PRM. The RRT rapidly generates further narrow passage samples, ideally until the passage is fully mapped. After reaching a terminating condition, the tree stops growing and is added to the roadmap. Spark PRM is a general method that can be applied to all PRM variants. We study the benefits of Spark PRM with a variety of sampling strategies in a wide array of environments. We show significant speedups in computation time over RRT, Sampling-based Roadmap of Trees (SRT), and various PRM variants.

  2. Spark PRM: Using RRTs within PRMs to efficiently explore narrow passages

    KAUST Repository

    Shi, Kensen

    2014-05-01

    © 2014 IEEE. Probabilistic RoadMaps (PRMs) have been successful for many high-dimensional motion planning problems. However, they encounter difficulties when mapping narrow passages. While many PRM sampling methods have been proposed to increase the proportion of samples within narrow passages, such difficult planning areas still pose many challenges. We introduce a novel algorithm, Spark PRM, that sparks the growth of Rapidly-expanding Random Trees (RRTs) from narrow passage samples generated by a PRM. The RRT rapidly generates further narrow passage samples, ideally until the passage is fully mapped. After reaching a terminating condition, the tree stops growing and is added to the roadmap. Spark PRM is a general method that can be applied to all PRM variants. We study the benefits of Spark PRM with a variety of sampling strategies in a wide array of environments. We show significant speedups in computation time over RRT, Sampling-based Roadmap of Trees (SRT), and various PRM variants.

  3. Gamma dose rate effect on JFET transistors

    International Nuclear Information System (INIS)

    Assaf, J.

    2011-04-01

    The effect of Gamma dose rate on JFET transistors is presented. The irradiation was accomplished at the following available dose rates: 1, 2.38, 5, 10 , 17 and 19 kGy/h at a constant dose of 600 kGy. A non proportional relationship between the noise and dose rate in the medium range (between 2.38 and 5 kGy/h) was observed. While in the low and high ranges, the noise was proportional to the dose rate as the case of the dose effect. This may be explained as follows: the obtained result is considered as the yield of a competition between many reactions and events which are dependent on the dose rate. At a given values of that events parameters, a proportional or a non proportional dose rate effects are generated. No dependence effects between the dose rate and thermal annealing recovery after irradiation was observed . (author)

  4. The basic approaches to evaluation of effects of the long-therm radiation exposure in a range of 'low' doses

    International Nuclear Information System (INIS)

    Takhauov, R.M.; Karpov, A.B.; Litvyakov, N.V.

    2010-01-01

    for evaluation the genetic effects of radiation exposure. DNA bank donors are workers of Siberian Group of Chemical Enterprises (SGCE) their descendants and also residents of the nearby territories. Taking into account the value of the accumulated material, it should be noted that DNA bank is one of the world's biggest biological material storage obtained from the exposed to long-term radiation influence in the range of 'low' doses. Due to present approaches using for evaluation of traditional and proposal stochastic effects of long-term radiation exposure in 'low' doses we can obtain the objective information of fundamental character. On the basis of this data it is possibility the additional of any radiation safety postulates and the development of the most importance diseases modern prophylactic strategy for populations exposuring radiation.

  5. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  6. Investigation of polymer composite for high dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, E.L.M.; Batista, A.S.M., E-mail: adriananuclear@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Ribeiro, F.A.S.; Santos, A.P.; Faria, L.O.; Oliveira, A.H. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Introduction: This paper presents the efficacy evaluation of PVDF and nanocomposites of the PVDF films for high gamma dosimetry. Our scope in this first part of our studies is the selection of the most promising film for future dosimetry trials, where the proportionality of response of the selected material will be investigated over a large range of doses and dose rates. Methods: Was prepared nanocomposites made by mixing Poly(vinylidene fluoride) (PVDF), zirconium oxide (ZrO{sub 2}) and multi-walled carbon nanotubes (MWCNTs) aiming to find dosimetric properties for applications in high dose dosimetry. The samples were irradiated with a Co-60 source at constant dose rate (16.7 kGy/h), with doses ranging from 100 to 2750 kGy. The UV-Vis and FTIR spectrophotometry have been used to monitor the appearing of C=C conjugated bonds and radio-oxidation of carbon (C=O). Results: FTIR spectrometry has that the absorbance intensities at 1715 cm{sup -1} and 1730 cm{sup -1} can be used for high dosimetry purposes for gamma doses ranging from 400 to 2750 kGy. In this range, it is possible to observe a linear relationship between Abs & Dose. Fading of signal was evaluated for one month and reproducibility in 2000 kGy dose. Conclusion: FTIR spectroscopic data revealed two optical absorption bands at 1715 cm{sup -1} and 1730 cm{sup -1} whose intensities are unambiguously related to gamma delivered dose ranging from 400 kGy to 2750 kGy. (author)

  7. Patient dose measurement and dose reduction in East Anglia (UK)

    International Nuclear Information System (INIS)

    Wade, J.P.; Goldstone, K.E.; Dendy, P.P.

    1995-01-01

    At the end of 1990 a programme of patient dose measurements was introduced as part of the quality assurance service already provided for X ray departments throughout the East Anglian Health Region (UK). Thermoluminescence dosemeters (TLDs) were used to measure over 1200 skin entrance surface doses for four common radiographic views in 33 hospitals in both the NHS and private sector. The four views were chosen to cover a wide range of equipment and techniques. The data collected have enabled Regional reference doses to be set which, for all views considered, fall below the National Radiological Protection Board (NRPB) Reference levels. In departments which exceeded reference levels, techniques were reviewed, improvements suggested and doses re-measured, in accordance with the recommended procedure for patient dose audit. A significant finding was that, given appropriate controls, X ray departments in the private sector could achieve the same acceptably low doses as NHS departments. (Author)

  8. Experimental determination of the radial dose distribution in high gradient regions around 192Ir wires: Comparison of electron paramagnetic resonance imaging, films, and Monte Carlo simulations

    International Nuclear Information System (INIS)

    Kolbun, N.; Leveque, Ph.; Abboud, F.; Bol, A.; Vynckier, S.; Gallez, B.

    2010-01-01

    Purpose: The experimental determination of doses at proximal distances from radioactive sources is difficult because of the steepness of the dose gradient. The goal of this study was to determine the relative radial dose distribution for a low dose rate 192 Ir wire source using electron paramagnetic resonance imaging (EPRI) and to compare the results to those obtained using Gafchromic EBT film dosimetry and Monte Carlo (MC) simulations. Methods: Lithium formate and ammonium formate were chosen as the EPR dosimetric materials and were used to form cylindrical phantoms. The dose distribution of the stable radiation-induced free radicals in the lithium formate and ammonium formate phantoms was assessed by EPRI. EBT films were also inserted inside in ammonium formate phantoms for comparison. MC simulation was performed using the MCNP4C2 software code. Results: The radical signal in irradiated ammonium formate is contained in a single narrow EPR line, with an EPR peak-to-peak linewidth narrower than that of lithium formate (∼0.64 and 1.4 mT, respectively). The spatial resolution of EPR images was enhanced by a factor of 2.3 using ammonium formate compared to lithium formate because its linewidth is about 0.75 mT narrower than that of lithium formate. The EPRI results were consistent to within 1% with those of Gafchromic EBT films and MC simulations at distances from 1.0 to 2.9 mm. The radial dose values obtained by EPRI were about 4% lower at distances from 2.9 to 4.0 mm than those determined by MC simulation and EBT film dosimetry. Conclusions: Ammonium formate is a suitable material under certain conditions for use in brachytherapy dosimetry using EPRI. In this study, the authors demonstrated that the EPRI technique allows the estimation of the relative radial dose distribution at short distances for a 192 Ir wire source.

  9. Thermal Loss Becomes an Issue for Tunable Narrow-band Antennas in Fourth Generation Handsets

    DEFF Research Database (Denmark)

    Barrio, Samantha Caporal Del; Morris, Art; Pedersen, Gert Frølund

    2015-01-01

    Antenna tuning is a very promising technique to cope with the expansion of the mobile communication frequency spectrum. Tunable antennas can address a wide range of operating frequencies, while being highly integrated. In particular, high-Q antennas (also named narrow-band antennas) are very...... compact, thus are good candidates to be embedded on fourth generation handsets. This study focuses on ‘high-Q’ tunable antennas and contributes with a characterisation of their loss mechanism, which is a major parameter in link-budget calculations. This study shows, through an example, that the tuner loss...

  10. 78 FR 23845 - Drawbridge Operation Regulations; Narrow Bay, Smith Point, NY

    Science.gov (United States)

    2013-04-23

    ... Operation Regulations; Narrow Bay, Smith Point, NY AGENCY: Coast Guard, DHS. ACTION: Notice of temporary... deviation from the regulation governing the operation of the Smith Point Bridge, mile 6.1, across Narrow Bay, between Smith Point and Fire Island, New York. The deviation is necessary to facilitate the Smith Point...

  11. Calibration of working standard ionization chambers and dose standardization

    International Nuclear Information System (INIS)

    Abd Elmahoud, A. A. B.

    2011-01-01

    Measurements were performed for the calibration of two working standard ionization chambers in the secondary standard dosimetry laboratory of Sudan. 600 cc cylindrical former type and 1800 cc cylindrical radical radiation protection level ionization chambers were calibrated against 1000 cc spherical reference standard ionization chamber. The chamber were calibrated at X-ray narrow spectrum series with beam energies ranged from (33-116 KeV) in addition to 1''3''7''Cs beam with 662 KeV energy. The chambers 0.6 cc and 0.3 cc therapy level ionization were used for dose standardization and beam output calibrations of cobalt-60 radiotherapy machine located at the National Cancer Institute, University of Gazira. Concerning beam output measurements for 6''0''Co radiotherapy machine, dosimetric measurements were performed in accordance with the relevant per IAEA dosimetry protocols TRS-277 and TRS-398. The kinetic energy released per unit mass in air (air kerma) were obtained by multiplying the corrected electrometer reading (nC/min) by the calibration factors (Gy/n C) of the chambers from given in the calibration certificate. The uncertainty of measurements of air kerma were calculated for the all ionization chambers (combined uncertainty) the calibration factors of these ionization chambers then were calculated by comparing the reading of air kerma of secondary standard ionization chambers to than from radical and farmer chambers. The result of calibration working standard ionization chambers showed different calibration factors ranged from 0.99 to 1.52 for different radiation energies and these differences were due to chambers response and specification. The absorbed dose to to water calculated for therapy ionization chamber using two code of practice TRS-277 and TRS-398 as beam output for 6''0''Co radiotherapy machine and it can be used as a reference for future beam output calibration in radiotherapy dosimetry. The measurement of absorbed dose to water showed that the

  12. The Effect of Divided Attention on Emotion-Induced Memory Narrowing

    OpenAIRE

    Steinmetz, Katherine R. Mickley; Waring, Jill D.; Kensinger, Elizabeth A.

    2013-01-01

    Individuals are more likely to remember emotional than neutral information, but this benefit does not always extend to the surrounding background information. This memory narrowing is theorized to be linked to the availability of attentional resources at encoding. In contrast to the predictions of this theoretical account, altering participants’ attentional resources at encoding, by dividing attention, did not affect the emotion-induced memory narrowing. Attention was divided using three sepa...

  13. Dose reconstruction modeling for medical radiation workers

    International Nuclear Information System (INIS)

    Choi, Yeong Chull; Cha, Eun Shil; Lee, Won Jin

    2017-01-01

    Exposure information is a crucial element for the assessment of health risk due to radiation. Radiation doses received by medical radiation workers have been collected and maintained by public registry since 1996. Since exposure levels in the remote past are greater concern, it is essential to reconstruct unmeasured doses in the past using known information. We developed retrodiction models for different groups of medical radiation workers and estimate individual past doses before 1996. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure.

  14. Dose reconstruction modeling for medical radiation workers

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yeong Chull; Cha, Eun Shil; Lee, Won Jin [Dept. of Preventive Medicine, Korea University, Seoul (Korea, Republic of)

    2017-04-15

    Exposure information is a crucial element for the assessment of health risk due to radiation. Radiation doses received by medical radiation workers have been collected and maintained by public registry since 1996. Since exposure levels in the remote past are greater concern, it is essential to reconstruct unmeasured doses in the past using known information. We developed retrodiction models for different groups of medical radiation workers and estimate individual past doses before 1996. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure. Reconstruction models for past radiation doses received by medical radiation workers were developed, and the past doses were estimated. Using these estimates, organ doses should be calculated which, in turn, will be used to explore a wide range of health risks of medical occupational radiation exposure.

  15. Cytogenetic effect of low dose gamma-radiation in Hordeum vulgare seedlings: non-linear dose-effect relationship.

    Science.gov (United States)

    Geras'kin, Stanislav A; Oudalova, Alla A; Kim, Jin Kyu; Dikarev, Vladimir G; Dikareva, Nina S

    2007-03-01

    The induction of chromosome aberrations in Hordeum vulgare germinated seeds was studied after ionizing irradiation with doses in the range of 10-1,000 mGy. The relationship between the frequency of aberrant cells and the absorbed dose was found to be nonlinear. A dose-independent plateau in the dose range from about 50 to 500 mGy was observed, where the level of cytogenetic damage was significantly different from the spontaneous level. The comparison of the goodness of the experimental data fitting with mathematical models of different complexity, using the most common quantitative criteria, demonstrated the advantage of a piecewise linear model over linear and polynomial models in approximating the frequency of cytogenetical disturbances. The results of the study support the hypothesis of indirect mechanisms of mutagenesis induced by low doses. Fundamental and applied implications of these findings are discussed.

  16. Bone-and-muscle-equivalent solid chemical dose meters for photon and electron doses above one kilorad

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Rosenstein, M.; Levine, H.

    1975-01-01

    Conventional solid dose meters, such as plastic films, powders, emulsions, glasses, ceramics and gels, have a response to ionizing photons and electrons that varies markedly over a broad spectrum when compared with the absorption characteristics of biological tissues. New radiochromic dyed plastic dose meters have been developed with X- and gamma ray and electron energy absorption cross-sections (calculated) and radiation energy responses (experimental) corresponding approximately to those for human muscle and bone, for a spectrum from a few keV to at least 10 MeV. Three-dimensional solid dose meters useful over the absorbed dose range of 10 3 to 10 6 rad are formed by thermosetting a selected combination of monomers containing the radiochromic dye in solution. Thin-film dose meters for the dose range 10 5 to 10 7 rad are formed by casting on optically flat surfaces strippable layers of special combinations of polymers and dyes in solution. The response of these systems to X- and gamma rays and electrons has been studied over various radiation spectra, dose-rates and temperatures during irradiation. (author)

  17. Epidemiological methods for assessing dose-response and dose-effect relationships

    DEFF Research Database (Denmark)

    Kjellström, Tord; Grandjean, Philippe

    2007-01-01

    Selected Molecular Mechanisms of Metal Toxicity and Carcinogenicity General Considerations of Dose-Effect and Dose-Response Relationships Interactions in Metal Toxicology Epidemiological Methods for Assessing Dose-Response and Dose-Effect Relationships Essential Metals: Assessing Risks from Deficiency......Description Handbook of the Toxicology of Metals is the standard reference work for physicians, toxicologists and engineers in the field of environmental and occupational health. This new edition is a comprehensive review of the effects on biological systems from metallic elements...... access to a broad range of basic toxicological data and also gives a general introduction to the toxicology of metallic compounds. Audience Toxicologists, physicians, and engineers in the fields of environmental and occupational health as well as libraries in these disciplines. Will also be a useful...

  18. Is There a Dose-Response Relationship for Heart Disease With Low-Dose Radiation Therapy?

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Eugene [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Corbett, James R. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Moran, Jean M. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Griffith, Kent A. [Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Marsh, Robin B.; Feng, Mary; Jagsi, Reshma; Kessler, Marc L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Ficaro, Edward C. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Pierce, Lori J., E-mail: ljpierce@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2013-03-15

    Purpose: To quantify cardiac radiation therapy (RT) exposure using sensitive measures of cardiac dysfunction; and to correlate dysfunction with heart doses, in the setting of adjuvant RT for left-sided breast cancer. Methods and Materials: On a randomized trial, 32 women with node-positive left-sided breast cancer underwent pre-RT stress single photon emission computed tomography (SPECT-CT) myocardial perfusion scans. Patients received RT to the breast/chest wall and regional lymph nodes to doses of 50 to 52.2 Gy. Repeat SPECT-CT scans were performed 1 year after RT. Perfusion defects (PD), summed stress defects scores (SSS), and ejection fractions (EF) were evaluated. Doses to the heart and coronary arteries were quantified. Results: The mean difference in pre- and post-RT PD was −0.38% ± 3.20% (P=.68), with no clinically significant defects. To assess for subclinical effects, PD were also examined using a 1.5-SD below the normal mean threshold, with a mean difference of 2.53% ± 12.57% (P=.38). The mean differences in SSS and EF before and after RT were 0.78% ± 2.50% (P=.08) and 1.75% ± 7.29% (P=.39), respectively. The average heart Dmean and D95 were 2.82 Gy (range, 1.11-6.06 Gy) and 0.90 Gy (range, 0.13-2.17 Gy), respectively. The average Dmean and D95 to the left anterior descending artery were 7.22 Gy (range, 2.58-18.05 Gy) and 3.22 Gy (range, 1.23-6.86 Gy), respectively. No correlations were found between cardiac doses and changes in PD, SSS, and EF. Conclusions: Using sensitive measures of cardiac function, no clinically significant defects were found after RT, with the average heart Dmean <5 Gy. Although a dose response may exist for measures of cardiac dysfunction at higher doses, no correlation was found in the present study for low doses delivered to cardiac structures and perfusion, SSS, or EF.

  19. Numerical simulation of narrow bipolar electromagnetic pulses generated by thunderstorm discharges

    Science.gov (United States)

    Bochkov, E. I.; Babich, L. P.; Kutsyk, I. M.

    2013-07-01

    Using the concept of avalanche relativistic runaway electrons (REs), we perform numerical simulations of compact intracloud discharge (CID) as a generator of powerful natural electromagnetic pulses (EMPs) in the HF-VHF range, called narrow bipolar pulses (NBPs). For several values of the field overvoltage and altitude at which the discharge develops, the numbers of seed electrons initiating the avalanche are evaluated, with which the calculated EMP characteristics are consistent with the measured NBP parameters. We note shortcomings in the hypothesis assuming participation of cosmic ray air showers in avalanche initiation. The discharge capable of generating NBPs produces REs in numbers close to those in the source of terrestrial γ-ray flashes (TGFs), which can be an argument in favor of a unified NBP and TGF source.

  20. Numerical simulation of narrow bipolar electromagnetic pulses generated by thunderstorm discharges

    International Nuclear Information System (INIS)

    Bochkov, E. I.; Babich, L. P.; Kutsyk, I. M.

    2013-01-01

    Using the concept of avalanche relativistic runaway electrons (REs), we perform numerical simulations of compact intracloud discharge (CID) as a generator of powerful natural electromagnetic pulses (EMPs) in the HF-VHF range, called narrow bipolar pulses (NBPs). For several values of the field overvoltage and altitude at which the discharge develops, the numbers of seed electrons initiating the avalanche are evaluated, with which the calculated EMP characteristics are consistent with the measured NBP parameters. We note shortcomings in the hypothesis assuming participation of cosmic ray air showers in avalanche initiation. The discharge capable of generating NBPs produces REs in numbers close to those in the source of terrestrial γ-ray flashes (TGFs), which can be an argument in favor of a unified NBP and TGF source

  1. Choline PET based dose-painting in prostate cancer - Modelling of dose effects

    International Nuclear Information System (INIS)

    Niyazi, Maximilian; Bartenstein, Peter; Belka, Claus; Ganswindt, Ute

    2010-01-01

    Several randomized trials have documented the value of radiation dose escalation in patients with prostate cancer, especially in patients with intermediate risk profile. Up to now dose escalation is usually applied to the whole prostate. IMRT and related techniques currently allow for dose escalation in sub-volumes of the organ. However, the sensitivity of the imaging modality and the fact that small islands of cancer are often dispersed within the whole organ may limit these approaches with regard to a clear clinical benefit. In order to assess potential effects of a dose escalation in certain sub-volumes based on choline PET imaging a mathematical dose-response model was developed. Based on different assumptions for α/β, γ50, sensitivity and specificity of choline PET, the influence of the whole prostate and simultaneous integrated boost (SIB) dose on tumor control probability (TCP) was calculated. Based on the given heterogeneity of all potential variables certain representative permutations of the parameters were chosen and, subsequently, the influence on TCP was assessed. Using schedules with 74 Gy within the whole prostate and a SIB dose of 90 Gy the TCP increase ranged from 23.1% (high detection rate of choline PET, low whole prostate dose, high γ50/ASTRO definition for tumor control) to 1.4% TCP gain (low sensitivity of PET, high whole prostate dose, CN + 2 definition for tumor control) or even 0% in selected cases. The corresponding initial TCP values without integrated boost ranged from 67.3% to 100%. According to a large data set of intermediate-risk prostate cancer patients the resulting TCP gains ranged from 22.2% to 10.1% (ASTRO definition) or from 13.2% to 6.0% (CN + 2 definition). Although a simplified mathematical model was employed, the presented model allows for an estimation in how far given schedules are relevant for clinical practice. However, the benefit of a SIB based on choline PET seems less than intuitively expected. Only under the

  2. Age- and gender-specific estimates of cumulative CT dose over 5 years using real radiation dose tracking data in children

    International Nuclear Information System (INIS)

    Lee, Eunsol; Goo, Hyun Woo; Lee, Jae-Yeong

    2015-01-01

    It is necessary to develop a mechanism to estimate and analyze cumulative radiation risks from multiple CT exams in various clinical scenarios in children. To identify major contributors to high cumulative CT dose estimates using actual dose-length product values collected for 5 years in children. Between August 2006 and July 2011 we reviewed 26,937 CT exams in 13,803 children. Among them, we included 931 children (median age 3.5 years, age range 0 days-15 years; M:F = 533:398) who had 5,339 CT exams. Each child underwent at least three CT scans and had accessible radiation dose reports. Dose-length product values were automatically extracted from DICOM files and we used recently updated conversion factors for age, gender, anatomical region and tube voltage to estimate CT radiation dose. We tracked the calculated CT dose estimates to obtain a 5-year cumulative value for each child. The study population was divided into three groups according to the cumulative CT dose estimates: high, ≥30 mSv; moderate, 10-30 mSv; and low, <10 mSv. We reviewed clinical data and CT protocols to identify major contributors to high and moderate cumulative CT dose estimates. Median cumulative CT dose estimate was 5.4 mSv (range 0.5-71.1 mSv), and median number of CT scans was 4 (range 3-36). High cumulative CT dose estimates were most common in children with malignant tumors (57.9%, 11/19). High frequency of CT scans was attributed to high cumulative CT dose estimates in children with ventriculoperitoneal shunt (35 in 1 child) and malignant tumors (range 18-49). Moreover, high-dose CT protocols, such as multiphase abdomen CT (median 4.7 mSv) contributed to high cumulative CT dose estimates even in children with a low number of CT scans. Disease group, number of CT scans, and high-dose CT protocols are major contributors to higher cumulative CT dose estimates in children. (orig.)

  3. MRI of surgically created pulmonary artery narrowing in the dog

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, R.J.; Rocchini, A.P.; Bove, E.L.; Chenevert, T.L.; Gubin, B. (Michigan Univ., Ann Arbor (USA). Dept. of Radiology)

    1989-11-01

    Narrowing of the pulmonary arteries was created surgically in twelve dogs. In six of the dogs the narrowing was central (main pulmonary artery), and in the remaining six the narrowing was located peripherally at the hilar level of the right pulmonary artery beyond the pericardial reflection. MRI and angiography were performed in all dogs. MRI clearly delineated the site of the pulmonary band and the caliber of the pulmonary artery at the site of the band in all dogs (N=6). MRI was not able to visualize any of the stenosis of the right pulmonary arteries at the hila, beyond the pericardial reflection. In addition, optimal imaging planes to depict each segment of the central pulmonary arteries were determined. The capability to image in oblique planes is essential in evaluating the morphology of the central pulmonary arteries. (orig.).

  4. MRI of surgically created pulmonary artery narrowing in the dog

    International Nuclear Information System (INIS)

    Hernandez, R.J.; Rocchini, A.P.; Bove, E.L.; Chenevert, T.L.; Gubin, B.

    1989-01-01

    Narrowing of the pulmonary arteries was created surgically in twelve dogs. In six of the dogs the narrowing was central (main pulmonary artery), and in the remaining six the narrowing was located peripherally at the hilar level of the right pulmonary artery beyond the pericardial reflection. MRI and angiography were performed in all dogs. MRI clearly delineated the site of the pulmonary band and the caliber of the pulmonary artery at the site of the band in all dogs (N=6). MRI was not able to visualize any of the stenosis of the right pulmonary arteries at the hila, beyond the pericardial reflection. In addition, optimal imaging planes to depict each segment of the central pulmonary arteries were determined. The capability to image in oblique planes is essential in evaluating the morphology of the central pulmonary arteries. (orig.)

  5. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  6. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  7. The effect of head size/shape, miscentering, and bowtie filter on peak patient tissue doses from modern brain perfusion 256-slice CT: How can we minimize the risk for deterministic effects?

    International Nuclear Information System (INIS)

    Perisinakis, Kostas; Seimenis, Ioannis; Tzedakis, Antonis; Papadakis, Antonios E.; Damilakis, John

    2013-01-01

    Purpose: To determine patient-specific absorbed peak doses to skin, eye lens, brain parenchyma, and cranial red bone marrow (RBM) of adult individuals subjected to low-dose brain perfusion CT studies on a 256-slice CT scanner, and investigate the effect of patient head size/shape, head position during the examination and bowtie filter used on peak tissue doses. Methods: The peak doses to eye lens, skin, brain, and RBM were measured in 106 individual-specific adult head phantoms subjected to the standard low-dose brain perfusion CT on a 256-slice CT scanner using a novel Monte Carlo simulation software dedicated for patient CT dosimetry. Peak tissue doses were compared to corresponding thresholds for induction of cataract, erythema, cerebrovascular disease, and depression of hematopoiesis, respectively. The effects of patient head size/shape, head position during acquisition and bowtie filter used on resulting peak patient tissue doses were investigated. The effect of eye-lens position in the scanned head region was also investigated. The effect of miscentering and use of narrow bowtie filter on image quality was assessed. Results: The mean peak doses to eye lens, skin, brain, and RBM were found to be 124, 120, 95, and 163 mGy, respectively. The effect of patient head size and shape on peak tissue doses was found to be minimal since maximum differences were less than 7%. Patient head miscentering and bowtie filter selection were found to have a considerable effect on peak tissue doses. The peak eye-lens dose saving achieved by elevating head by 4 cm with respect to isocenter and using a narrow wedge filter was found to approach 50%. When the eye lies outside of the primarily irradiated head region, the dose to eye lens was found to drop to less than 20% of the corresponding dose measured when the eye lens was located in the middle of the x-ray beam. Positioning head phantom off-isocenter by 4 cm and employing a narrow wedge filter results in a moderate reduction of

  8. Irradiation Creep of Ferritic-Martensitic Steels EP-450, EP-823 and EI-852 Irradiated in the BN-350 Reactor over Wide Ranges of Irradiation Temperature and Dose

    International Nuclear Information System (INIS)

    Porollo, S.I.; Konobeev, Y.V.; Ivanov, A.A.; Shulepin, S.V.; Garner, F.

    2007-01-01

    Full text of publication follows: Ferritic/martensitic (F/M) steels appear to be the most promising materials for advanced nuclear systems, especially for fusion reactors. Their main advantages are higher resistance to swelling and lower irradiation creep rate as has been repeatedly demonstrated in examinations of these materials after irradiation. Nevertheless, available experimental data on irradiation resistance of F/M steels are insufficient, with the greatest deficiency of data for high doses and for both low and high irradiation temperatures. From the very beginning of operation the BN-350 fast reactor has been used for irradiation of specimens of structural materials, including F/M steels. The most unique feature of BN-350 was its low inlet sodium temperature, allowing irradiation at temperatures over a very wide range of temperatures compared with the range in other fast reactors. In this paper data are presented on swelling and irradiation creep of three Russian F/M steels EP-450, EP-823 and EI-852, irradiated in experimental assemblies of the BN-350 reactor at temperatures in the range of 305-700 deg. C to doses ranging from 20 to 89 dpa. The investigation was performed using gas-pressurized creep tubes with hoop stresses in the range of 0 - 294 MPa. (authors)

  9. Comparison of two dose and three dose human papillomavirus vaccine schedules: cost effectiveness analysis based on transmission model.

    Science.gov (United States)

    Jit, Mark; Brisson, Marc; Laprise, Jean-François; Choi, Yoon Hong

    2015-01-06

    To investigate the incremental cost effectiveness of two dose human papillomavirus vaccination and of additionally giving a third dose. Cost effectiveness study based on a transmission dynamic model of human papillomavirus vaccination. Two dose schedules for bivalent or quadrivalent human papillomavirus vaccines were assumed to provide 10, 20, or 30 years' vaccine type protection and cross protection or lifelong vaccine type protection without cross protection. Three dose schedules were assumed to give lifelong vaccine type and cross protection. United Kingdom. Males and females aged 12-74 years. No, two, or three doses of human papillomavirus vaccine given routinely to 12 year old girls, with an initial catch-up campaign to 18 years. Costs (from the healthcare provider's perspective), health related utilities, and incremental cost effectiveness ratios. Giving at least two doses of vaccine seems to be highly cost effective across the entire range of scenarios considered at the quadrivalent vaccine list price of £86.50 (€109.23; $136.00) per dose. If two doses give only 10 years' protection but adding a third dose extends this to lifetime protection, then the third dose also seems to be cost effective at £86.50 per dose (median incremental cost effectiveness ratio £17,000, interquartile range £11,700-£25,800). If two doses protect for more than 20 years, then the third dose will have to be priced substantially lower (median threshold price £31, interquartile range £28-£35) to be cost effective. Results are similar for a bivalent vaccine priced at £80.50 per dose and when the same scenarios are explored by parameterising a Canadian model (HPV-ADVISE) with economic data from the United Kingdom. Two dose human papillomavirus vaccine schedules are likely to be the most cost effective option provided protection lasts for at least 20 years. As the precise duration of two dose schedules may not be known for decades, cohorts given two doses should be closely

  10. Assessing the Utility of Compound Trait Estimates of Narrow Personality Traits.

    Science.gov (United States)

    Credé, Marcus; Harms, Peter D; Blacksmith, Nikki; Wood, Dustin

    2016-01-01

    It has been argued that approximations of narrow traits can be made through linear combinations of broad traits such as the Big Five personality traits. Indeed, Hough and Ones ( 2001 ) used a qualitative analysis of scale content to arrive at a taxonomy of how Big Five traits might be combined to approximate various narrow traits. However, the utility of such compound trait approximations has yet to be established beyond specific cases such as integrity and customer service orientation. Using data from the Eugene-Springfield Community Sample (Goldberg, 2008 ), we explore the ability of linear composites of scores on Big Five traits to approximate scores on 127 narrow trait measures from 5 well-known non-Big-Five omnibus measures of personality. Our findings indicate that individuals' standing on more than 30 narrow traits can be well estimated from 3 different types of linear composites of scores on Big Five traits without a substantial sacrifice in criterion validity. We discuss theoretical accounts for why such relationships exist as well as the theoretical and practical implications of these findings for researchers and practitioners.

  11. Einstein-Podolsky-Rosen Entanglement of Narrow-Band Photons from Cold Atoms

    Science.gov (United States)

    Lee, Jong-Chan; Park, Kwang-Kyoon; Zhao, Tian-Ming; Kim, Yoon-Ho

    2016-12-01

    Einstein-Podolsky-Rosen (EPR) entanglement introduced in 1935 deals with two particles that are entangled in their positions and momenta. Here we report the first experimental demonstration of EPR position-momentum entanglement of narrow-band photon pairs generated from cold atoms. By using two-photon quantum ghost imaging and ghost interference, we demonstrate explicitly that the narrow-band photon pairs violate the separability criterion, confirming EPR entanglement. We further demonstrate continuous variable EPR steering for positions and momenta of the two photons. Our new source of EPR-entangled narrow-band photons is expected to play an essential role in spatially multiplexed quantum information processing, such as, storage of quantum correlated images, quantum interface involving hyperentangled photons, etc.

  12. Einstein-Podolsky-Rosen Entanglement of Narrow-Band Photons from Cold Atoms.

    Science.gov (United States)

    Lee, Jong-Chan; Park, Kwang-Kyoon; Zhao, Tian-Ming; Kim, Yoon-Ho

    2016-12-16

    Einstein-Podolsky-Rosen (EPR) entanglement introduced in 1935 deals with two particles that are entangled in their positions and momenta. Here we report the first experimental demonstration of EPR position-momentum entanglement of narrow-band photon pairs generated from cold atoms. By using two-photon quantum ghost imaging and ghost interference, we demonstrate explicitly that the narrow-band photon pairs violate the separability criterion, confirming EPR entanglement. We further demonstrate continuous variable EPR steering for positions and momenta of the two photons. Our new source of EPR-entangled narrow-band photons is expected to play an essential role in spatially multiplexed quantum information processing, such as, storage of quantum correlated images, quantum interface involving hyperentangled photons, etc.

  13. Experimental study on occupant evacuation in narrow seat aisle

    Science.gov (United States)

    Huang, Shenshi; Lu, Shouxiang; Lo, Siuming; Li, Changhai; Guo, Yafei

    2018-07-01

    Narrow seat aisle is an important area in the train car interior due to the large passenger population, however evacuation therein has not gained enough concerns. In this experimental study, the occupant evacuation of the narrow seat aisle area is investigated, with the aisle width of 0.4-0.6 m and the evacuation direction of forward and backward. The evacuation behaviors are analyzed based on the video record, and the discussion is carried out in the aspect of evacuation time, crowdedness, evacuation order, and aisle conflicts. The result shows that with the increasing aisle width, total evacuation time and the average specific evacuation rate decrease. The aisle is crowded for some time, with a large linear occupant densities. The evacuation order of each occupant is mainly related to the seat position. Moreover, it is found that the aisle conflicts can be well described by Burstedde's model. This study gives a useful benchmark for evacuation simulation of narrow seat aisle, and provides reference to safety design of seat area in train cars.

  14. Dose gradient curve: A new tool for evaluating dose gradient.

    Science.gov (United States)

    Sung, KiHoon; Choi, Young Eun

    2018-01-01

    Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice.

  15. On Dynamic Range Limitations of CMOS Current Conveyors

    DEFF Research Database (Denmark)

    Bruun, Erik

    1999-01-01

    frequency band and for the situation where the conveyor is used over the full bandwidth achievable. Finally, the optimisation of the current input range is related to the distortion characteristics and it is pointed out that to a first order approximation the distortion is independent of the current range.......This paper is concerned with the dynamic range of continuous time CMOS current mode circuits. As a representative current mode device a class AB current conveyor is examined. First, the voltage input range of the high impedance Y input is investigated. Next, the current input range of the low...... impedance X input is investigated. It is compared to the thermal noise in the X to Z signal path in order to evaluate the dynamic range, and the dependencies of the dynamic range on the supply voltage and the transistor lay-out is derived, both for the situation where the conveyor is used over a narrow...

  16. The narrow-gap TIG welding concerns the electric power plants manufacturers

    International Nuclear Information System (INIS)

    Anon.

    2009-01-01

    Polysoude, France, played host to an expert forum on narrow gap welding from 5-7 November 2008. The successful event welcomed around one hundred experts.The power plant construction sector is currently booming worldwide. For plant construction this means using more pressure-resistant, thick-walled pipes made from high temperature steels. The key quality features of this new steel grade are the values for high creep rupture strength that also apply without restriction as the benchmark for every weld seam on these pipes. In particular, the forum on narrow gap welding addressed this area of automated welding technology. During the forum, Mr Hans-Peter Mariner (Polysoude's CEO), has offered an in-depth insight into the latest developments in narrow gap welding. This presentation highlighted that with wall thicknesses of over 60 mm, welding time is shortened by a factor of five to ten in comparison to conventional TIG processes with a traditional V seam. The welding characteristics of the parent material are the decisive factor in the application of the narrow gap process. Technical advances in equipment technology such as automatic centring, HF-free ignition, seam preparation and optimised gas protection further increase the application limits. The geometry and gap width of the weld groove are based on the mechanical properties of the materials being joined, with the shrinkage characteristics of the seam being particularly important. Another key part of the programme was a presentation on the three different narrow gap-welding techniques. The first involves a single pass weld per layer and torch or work-piece revolution. The second is dual pass welding next to one another, when the seam preparation or positioning exceed the required narrow tolerances of a few tenths of a millimetre for one stringer bead per layer. TIG narrow gap welding with a shuttle-motion electrode is ideal with very large wall thicknesses of 150-200 mm. This is particularly the case if the

  17. The Effect of Broadened Ranges of Expectancy on Satisfaction with Performance

    Science.gov (United States)

    1988-08-01

    Campbell, D.T. (1971). Hedonic relativism and planning the good society . In M.H. Appley (Ed.), Adaptation-level theory. New York: Academic Press. "€ Brickman...a lower plausible outcome within the expectancy range and see the current outcome as favorable (e.g. This is a good score. It was possible that I...improvement). Persons with narrow ranges of expectancies cannot make these hedonically preferable selective comparisons. Giving Up Too Early and

  18. Safety, immunogenicity and dose ranging of a new Vi-CRM₁₉₇ conjugate vaccine against typhoid fever: randomized clinical testing in healthy adults.

    Science.gov (United States)

    van Damme, Pierre; Kafeja, Froukje; Anemona, Alessandra; Basile, Venere; Hilbert, Anne Katrin; De Coster, Ilse; Rondini, Simona; Micoli, Francesca; Qasim Khan, Rana M; Marchetti, Elisa; Di Cioccio, Vito; Saul, Allan; Martin, Laura B; Podda, Audino

    2011-01-01

    Typhoid fever causes more than 21 million cases of disease and 200,000 deaths yearly worldwide, with more than 90% of the disease burden being reported from Asia. Epidemiological data show high disease incidence in young children and suggest that immunization programs should target children below two years of age: this is not possible with available vaccines. The Novartis Vaccines Institute for Global Health developed a conjugate vaccine (Vi-CRM₁₉₇) for infant vaccination concomitantly with EPI vaccines, either starting at 6 weeks with DTP or at 9 months with measles vaccine. We report the results from a Phase 1 and a Phase 2 dose ranging trial with Vi-CRM₁₉₇ in European adults. Following randomized blinded comparison of single vaccination with either Vi-CRM₁₉₇ or licensed polysaccharide vaccines (both containing 25·0 µg of Vi antigen), a randomised observer blinded dose ranging trial was performed in the same center to compare three concentrations of Vi-CRM₁₉₇ (1·25 µg, 5·0 µg and 12·5 µg of Vi antigen) with the polysaccharide vaccine. All vaccines were well tolerated. Compared to the polysaccharide vaccine, Vi-CRM₁₉₇ induced a higher incidence of mild to moderate short lasting local pain. All Vi-CRM₁₉₇ formulations induced higher Vi antibody levels compared to licensed control, with clear dose response relationship. Vi-CRM₁₉₇ did not elicit safety concerns, was highly immunogenic and is therefore suitable for further clinical testing in endemic populations of South Asia. ClinicalTrials.gov NCT01123941 NCT01193907.

  19. Investigations of glass structure using fluorescence line narrowing and moleuclar dynamics simulations

    International Nuclear Information System (INIS)

    Weber, M.J.; Brawer, S.A.

    1982-01-01

    The local structure at individual ion sites in simple and multicomponent glasses is simulated using methods of molecular dynamics. Computer simulations of fluoroberyllate glasses predict a range of ion separations and coordination numbers that increases with increasing complexity of the glass composition. This occurs at both glass forming and glass modifying cation sites. Laser-induced fluorescence line-narrowing techniques provide a unique probe of the local environments of selected subsets of ions and are used to measure site to site variations in the electronic energy levels and transition probabilities of rare earth ions. These and additional results from EXAFS, neutron and x-ray diffraction, and NMR experiments are compared with simulated glass structures

  20. Radiological dose assessment for residual radioactive material in soil at the clean slate sites 1, 2, and 3, Tonopah Test Range

    International Nuclear Information System (INIS)

    1997-06-01

    A radiological dose assessment has been performed for Clean Slate Sites 1, 2, and 3 at the Tonopah Test Range, approximately 390 kilometers (240 miles) northwest of Las Vegas, Nevada. The assessment demonstrated that the calculated dose to hypothetical individuals who may reside or work on the Clean Slate sites, subsequent to remediation, does not exceed the limits established by the US Department of Energy for protection of members of the public and the environment. The sites became contaminated as a result of Project Roller Coaster experiments conducted in 1963 in support of the US Atomic Energy Commission (Shreve, 1964). Remediation of Clean Slate Sites 1, 2, and 3 is being performed to ensure that the 50-year committed effective dose equivalent to a hypothetical individual who lives or works on a Clean Slate site should not exceed 100 millirems per year. The DOE residual radioactive material guideline (RESRAD) computer code was used to assess the dose. RESRAD implements the methodology described in the DOE manual for establishing residual radioactive material guidelines (Yu et al., 1993a). In May and June of 1963, experiments were conducted at Clean Slate Sites 1, 2, and 3 to study the effectiveness of earth-covered structures for reducing the dispersion of nuclear weapons material as a result of nonnuclear explosions. The experiments required the detonation of various simulated weapons using conventional chemical explosives (Shreve, 1964). The residual radioactive contamination in the surface soil consists of weapons grade plutonium, depleted uranium, and their radioactive decay products

  1. Radiological dose assessment for residual radioactive material in soil at the clean slate sites 1, 2, and 3, Tonopah Test Range

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    A radiological dose assessment has been performed for Clean Slate Sites 1, 2, and 3 at the Tonopah Test Range, approximately 390 kilometers (240 miles) northwest of Las Vegas, Nevada. The assessment demonstrated that the calculated dose to hypothetical individuals who may reside or work on the Clean Slate sites, subsequent to remediation, does not exceed the limits established by the US Department of Energy for protection of members of the public and the environment. The sites became contaminated as a result of Project Roller Coaster experiments conducted in 1963 in support of the US Atomic Energy Commission (Shreve, 1964). Remediation of Clean Slate Sites 1, 2, and 3 is being performed to ensure that the 50-year committed effective dose equivalent to a hypothetical individual who lives or works on a Clean Slate site should not exceed 100 millirems per year. The DOE residual radioactive material guideline (RESRAD) computer code was used to assess the dose. RESRAD implements the methodology described in the DOE manual for establishing residual radioactive material guidelines (Yu et al., 1993a). In May and June of 1963, experiments were conducted at Clean Slate Sites 1, 2, and 3 to study the effectiveness of earth-covered structures for reducing the dispersion of nuclear weapons material as a result of nonnuclear explosions. The experiments required the detonation of various simulated weapons using conventional chemical explosives (Shreve, 1964). The residual radioactive contamination in the surface soil consists of weapons grade plutonium, depleted uranium, and their radioactive decay products.

  2. Digital technique for the study of narrow structure in electron-atom and electron-molecule scattering

    International Nuclear Information System (INIS)

    Paske, W.C.; Shadfar, S.; Lorentz, S.R.; Steph, N.C.; Golden, D.E.

    1981-01-01

    A digital technique has been developed which allows the study of narrow structure in total electron-atom and electron-molecule scattering cross sections without requiring a highly monoenergetic electron beam, modulation of the electron gun, or phase sensitive detection. The electron current transmitted through a gas cell is digitized as the electron energy is stepped by ΔE through the energy range of interest. A transmitted electron difference signal is then obtained using a computer. As examples of this technique, the difference spectra are presented for He near 19.35 eV and for N 2 for the energy range from 10.3 to 15.0 eV. In the present case an instrumental resolution of 30 meV FWHM has been obtained

  3. Pressure Fluctuation Characteristics of Narrow Gauge Train Running Through Tunnel

    Science.gov (United States)

    Suzuki, Masahiro; Sakuma, Yutaka

    Pressure fluctuations on the sides of narrow (1067 mm) gauge trains running in tunnels are measured for the first time to investigate the aerodynamic force acting on the trains. The present measurements are compared with earlier measurements obtained with the Shinkansen trains. The results are as follows: (1) The aerodynamic force, which stems from pressure fluctuations on the sides of cars, puts the energy into the vibration of the car body running through a tunnel. (2) While the pressure fluctuations appear only on one of the two sides of the trains running in double-track tunnels, the fluctuations in opposite phase on both sides in single-track tunnels. (3) The on-track test data of the narrow gauge trains show the same tendency as those of the Shinkansen trains, although it is suggested that the pressure fluctuations develop faster along the narrow gauge trains than the Shinkansen trains.

  4. CT demonstration of pharyngeal narrowing in adult obstructive sleep apnea

    International Nuclear Information System (INIS)

    Bohlman, M.E.; Haponik, E.F.; Smith, P.L.; Allen, R.P.; Bleecker, E.R.; Goldman, S.M.

    1983-01-01

    Sleep apnea is a major cause of daytime hypersomnolence. Among the proposed etiologies, focal obstruction of the airways at the level of the pharynx has been suggested but not proven. Using computed tomography, the cross-sectional area of the airway can be readily assessed. Thirty-three adults with clinically proven sleep apnea and 12 normal adults underwent systematic computed tomography of the neck. Significant airway narrowing was demonstrated in all the patients with obstructive sleep apnea, whereas no such narrowing was seen in the controls. In 11, the narrowing was at a single level, whereas in 22 patients two or more levels were affected. This study has shown that a structurally abnormal airway may serve as an anatomic substrate for the development of sleep apnea. On the basis of this evidence, uvulopalatopharyngoplasty has been performed in two patients with relief of symptoms in one

  5. A Dose-Volume Analysis of Magnetic Resonance Imaging-Aided High-Dose-Rate Image-Based Interstitial Brachytherapy for Uterine Cervical Cancer

    International Nuclear Information System (INIS)

    Yoshida, Ken; Yamazaki, Hideya; Takenaka, Tadashi; Kotsuma, Tadayuki; Yoshida, Mineo; Furuya, Seiichi; Tanaka, Eiichi; Uegaki, Tadaaki; Kuriyama, Keiko; Matsumoto, Hisanobu; Yamada, Shigetoshi; Ban, Chiaki

    2010-01-01

    Purpose: To investigate the feasibility of our novel image-based high-dose-rate interstitial brachytherapy (HDR-ISBT) for uterine cervical cancer, we evaluated the dose-volume histogram (DVH) according to the recommendations of the Gynecological GEC-ESTRO Working Group for image-based intracavitary brachytherapy (ICBT). Methods and Materials: Between June 2005 and June 2007, 18 previously untreated cervical cancer patients were enrolled. We implanted magnetic resonance imaging (MRI)-available plastic applicators by our unique ambulatory technique. Total treatment doses were 30-36 Gy (6 Gy per fraction) combined with external beam radiotherapy (EBRT). Treatment plans were created based on planning computed tomography with MRI as a reference. DVHs of the high-risk clinical target volume (HR CTV), intermediate-risk CTV (IR CTV), and the bladder and rectum were calculated. Dose values were biologically normalized to equivalent doses in 2-Gy fractions (EQD 2 ). Results: The median D90 (HR CTV) and D90 (IR CTV) per fraction were 6.8 Gy (range, 5.5-7.5) and 5.4 Gy (range, 4.2-6.3), respectively. The median V100 (HR CTV) and V100 (IR CTV) were 98.4% (range, 83-100) and 81.8% (range, 64-93.8), respectively. When the dose of EBRT was added, the median D90 and D100 of HR CTV were 80.6 Gy (range, 65.5-96.6) and 62.4 Gy (range, 49-83.2). The D 2cc of the bladder was 62 Gy (range, 51.4-89) and of the rectum was 65.9 Gy (range, 48.9-76). Conclusions: Although the targets were advanced and difficult to treat effectively by ICBT, MRI-aided image-based ISBT showed favorable results for CTV and organs at risk compared with previously reported image-based ICBT results.

  6. A dose-volume analysis of magnetic resonance imaging-aided high-dose-rate image-based interstitial brachytherapy for uterine cervical cancer.

    Science.gov (United States)

    Yoshida, Ken; Yamazaki, Hideya; Takenaka, Tadashi; Kotsuma, Tadayuki; Yoshida, Mineo; Furuya, Seiichi; Tanaka, Eiichi; Uegaki, Tadaaki; Kuriyama, Keiko; Matsumoto, Hisanobu; Yamada, Shigetoshi; Ban, Chiaki

    2010-07-01

    To investigate the feasibility of our novel image-based high-dose-rate interstitial brachytherapy (HDR-ISBT) for uterine cervical cancer, we evaluated the dose-volume histogram (DVH) according to the recommendations of the Gynecological GEC-ESTRO Working Group for image-based intracavitary brachytherapy (ICBT). Between June 2005 and June 2007, 18 previously untreated cervical cancer patients were enrolled. We implanted magnetic resonance imaging (MRI)-available plastic applicators by our unique ambulatory technique. Total treatment doses were 30-36 Gy (6 Gy per fraction) combined with external beam radiotherapy (EBRT). Treatment plans were created based on planning computed tomography with MRI as a reference. DVHs of the high-risk clinical target volume (HR CTV), intermediate-risk CTV (IR CTV), and the bladder and rectum were calculated. Dose values were biologically normalized to equivalent doses in 2-Gy fractions (EQD(2)). The median D90 (HR CTV) and D90 (IR CTV) per fraction were 6.8 Gy (range, 5.5-7.5) and 5.4 Gy (range, 4.2-6.3), respectively. The median V100 (HR CTV) and V100 (IR CTV) were 98.4% (range, 83-100) and 81.8% (range, 64-93.8), respectively. When the dose of EBRT was added, the median D90 and D100 of HR CTV were 80.6 Gy (range, 65.5-96.6) and 62.4 Gy (range, 49-83.2). The D(2cc) of the bladder was 62 Gy (range, 51.4-89) and of the rectum was 65.9 Gy (range, 48.9-76). Although the targets were advanced and difficult to treat effectively by ICBT, MRI-aided image-based ISBT showed favorable results for CTV and organs at risk compared with previously reported image-based ICBT results. (c) 2010 Elsevier Inc. All rights reserved.

  7. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  8. Thermoluminescence and phosphate glass dosimeter systems in the low dose range

    International Nuclear Information System (INIS)

    Piesch, E.; Burgkhardt, B.

    1978-06-01

    This report describes a standard test program for TLD and RPL systems worked out by the Working Party on 'Dose Measurement of External Radiation' by the Fachverband fuer Strahlenschutz e.V. to demonstrate the performance of dosimeter systems to be employed in environmental monitoring and in personnel dosimetry. The results of an intercomparison study are outlined in which 17 laboratories from the German speaking countries participated with 43 dosimeter systems. (orig.) [de

  9. High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.

    Science.gov (United States)

    Jaccard, Maud; Petersson, Kristoffer; Buchillier, Thierry; Germond, Jean-François; Durán, Maria Teresa; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François O; Bailat, Claude

    2017-02-01

    The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋ m ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋ p ) of up to 8 × 10 6 Gy/s. To do this, we evaluated the overall uncertainties in EBT3 film dosimetry as well as the energy and dose-rate dependence of their response. Our dosimetric system was composed of EBT3 Gafchromic films in combination with a flatbed scanner and was calibrated against an ionization chamber traceable to primary standard. All sources of uncertainties in EBT3 dosimetry were carefully analyzed using irradiations at a clinical radiotherapy linac. Energy dependence was investigated with the same machine by acquiring and comparing calibration curves for three different beam energies (4, 8 and 12 MeV), for doses between 0.25 and 30 Gy. Ḋ m dependence was studied at the clinical linac by changing the pulse repetition frequency (f) of the beam in order to vary Ḋ m between 0.55 and 4.40 Gy/min, while Ḋ p dependence was probed at the prototype machine for Ḋ p ranging from 7 × 10 3 to 8 × 10 6 Gy/s. Ḋ p dependence was first determined by studying the correlation between the dose measured by films and the charge of electrons measured at the exit of the machine by an induction torus. Furthermore, we compared doses from the films to independently calibrated thermo-luminescent dosimeters (TLD) that have been reported as being dose-rate independent up to such high dose-rates. We report that uncertainty below 4% (k = 2) can be achieved in the dose range between 3 and 17 Gy. Results also demonstrated that EBT3 films did not display any detectable energy dependence for electron beam energies between 4 and 12 MeV. No Ḋ m dependence was found either. In addition, we obtained excellent consistency between films and TLDs over the entire Ḋ p

  10. Long range implantation by MEVVA metal ion source

    International Nuclear Information System (INIS)

    Zhang Tonghe; Wu Yuguang; Ma Furong; Liang Hong

    2001-01-01

    Metal vapor vacuum arc (MEVVA) source ion implantation is a new technology used for achieving long range ion implantation. It is very important for research and application of the ion beam modification of materials. The results show that the implanted atom diffusion coefficient increases in Mo implanted Al with high ion flux and high dose. The implanted depth is 311.6 times greater than that of the corresponding ion range. The ion species, doses and ion fluxes play an important part in the long-range implantation. Especially, thermal atom chemistry have specific effect on the long-range implantation during high ion flux implantation at transient high target temperature

  11. Radiochromic Plastic Films for Accurate Measurement of Radiation Absorbed Dose and Dose Distributions

    DEFF Research Database (Denmark)

    McLaughlin, W. L.; Miller, Arne; Fidan, S.

    1977-01-01

    of dose rate (1–1014 rad s−1). Upon irradiation of the film, the profile of the radiation field is registered as a permanent colored image of the dose distribution. Unlike most other types of dyed plastic dose meters, the optical density produced by irradiation is in most cases stable for periods...... of many polymeric systems in industrial radiation processing. The result is that errors due to energy dependence of response of the radiation sensor are effectively reduced, since the spectral sensitivity of the dose meter matches that of the polymer of interest, over a wide range of photon and electron...

  12. Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium

    International Nuclear Information System (INIS)

    Fonseca, Gabriel Paiva; Yoriyaz, Hélio; Tedgren, Åsa Carlsson; Nilsson, Josef; Persson, Maria; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Dose calculation in high dose rate brachytherapy with 192 Ir is usually based on the TG-43U1 protocol where all media are considered to be water. Several dose calculation algorithms have been developed that are capable of handling heterogeneities with two possibilities to report dose: dose-to-medium-in-medium (D m,m ) and dose-to-water-in-medium (D w,m ). The relation between D m,m and D w,m for 192 Ir is the main goal of this study, in particular the dependence of D w,m on the dose calculation approach using either large cavity theory (LCT) or small cavity theory (SCT). A head and neck case was selected due to the presence of media with a large range of atomic numbers relevant to tissues and mass densities such as air, soft tissues and bone interfaces. This case was simulated using a Monte Carlo (MC) code to score: D m,m, D w,m (LCT), mean photon energy and photon fluence. D w,m (SCT) was derived from MC simulations using the ratio between the unrestricted collisional stopping power of the actual medium and water. Differences between D m,m and D w,m (SCT or LCT) can be negligible (<1%) for some tissues e.g. muscle and significant for other tissues with differences of up to 14% for bone. Using SCT or LCT approaches leads to differences between D w,m (SCT) and D w,m (LCT) up to 29% for bone and 36% for teeth. The mean photon energy distribution ranges from 222 keV up to 356 keV. However, results obtained using mean photon energies are not equivalent to the ones obtained using the full, local photon spectrum. This work concludes that it is essential that brachytherapy studies clearly report the dose quantity. It further shows that while differences between D m,m and D w,m (SCT) mainly depend on tissue type, differences between D m,m and D w,m (LCT) are, in addition, significantly dependent on the local photon energy fluence spectrum which varies with distance to implanted sources. (paper)

  13. Is it sensible to “deform” dose? 3D experimental validation of dose-warping

    International Nuclear Information System (INIS)

    Yeo, U. J.; Taylor, M. L.; Supple, J. R.; Smith, R. L.; Dunn, L.; Kron, T.; Franich, R. D.

    2012-01-01

    Purpose: Strategies for dose accumulation in deforming anatomy are of interest in radiotherapy. Algorithms exist for the deformation of dose based on patient image sets, though these are sometimes contentious because not all such image calculations are constrained by physical laws. While tumor and organ motion has been a key area of study for a considerable amount of time, deformation is of increasing interest. In this work, we demonstrate a full 3D experimental validation of results from a range of dose deformation algorithms available in the public domain. Methods: We recently developed the first tissue-equivalent, full 3D deformable dosimetric phantom—“DEFGEL.” To assess the accuracy of dose-warping based on deformable image registration (DIR), we have measured doses in undeformed and deformed states of the DEFGEL dosimeter and compared these to planned doses and warped doses. In this way we have directly evaluated the accuracy of dose-warping calculations for 11 different algorithms. We have done this for a range of stereotactic irradiation schemes and types and magnitudes of deformation. Results: The original Horn and Schunck algorithm is shown to be the best performing of the 11 algorithms trialled. Comparing measured and dose-warped calculations for this method, it is found that for a 10 × 10 mm 2 square field, γ 3%/3mm = 99.9%; for a 20 × 20 mm 2 cross-shaped field, γ 3%/3mm = 99.1%; and for a multiple dynamic arc (0.413 cm 3 PTV) treatment adapted from a patient treatment plan, γ 3%/3mm = 95%. In each case, the agreement is comparable to—but consistently ∼1% less than—comparison between measured and calculated (planned) dose distributions in the absence of deformation. The magnitude of the deformation, as measured by the largest displacement experienced by any voxel in the volume, has the greatest influence on the accuracy of the warped dose distribution. Considering the square field case, the smallest deformation (∼9 mm) yields

  14. Sensor based on Fano resonances of plane metamaterial with narrow slits

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Wan-Xia, E-mail: kate@mail.ahnu.edu.cn [State Key Laboratory of Surface Physics, Key Laboratory of Micro and Nano Photonic Structures (Ministry of Education) and Physics Department, Fudan University, Shanghai 200433 (China); The College of Physics and Electronic Information, Anhui Normal University, Wuhu, Anhui 241000 (China); Guo, Juan-Juan; Wang, Mao-Sheng; Zhao, Guo-Ren [The College of Physics and Electronic Information, Anhui Normal University, Wuhu, Anhui 241000 (China)

    2017-03-11

    The optical properties of a composite metamaterial composed of narrow slits and nano hole pairs have been investigated experimentally and numerically. The strength of the transmission peak originating from the interference between the coupled surface plasmon polaritons (SPP) of the narrow slit and the SPP modes of the hole array is modulated by the degree of symmetry breaking. Some SPP modes can be inhibited by controlling the spacer layer thickness. Our metamaterial has potential applications in sensing and weak signal detection. - Highlights: • The plasmonic nanostructure composed of narrow slits and nano hole pairs were designed. • The optical properties were investigated experimentally and numerically. • The Fano resonances were found on the compound nanostructure. • The results have potential applications in sensing and weak signal detection.

  15. Slight conductive hearing loss in children with narrowed maxilla and deep palatal vault.

    Science.gov (United States)

    Kiki, A; Kiliç, N; Oktay, H

    2015-01-01

    PROBLEM/OBJECTIVES: Maxillary constriction and high palatal arch are associated with increased risk of chronic eustachian tube dysfunction and conductive hearing loss (CHL) due to chronic effusion. However, this relationship has not been clearly demonstrated. This study assessed CHL in school children with a narrowed maxilla and deep palatal vault. Thirty-two children with maxillary constriction were randomly selected for the study group and 28 children with normal transverse maxillary development were selected for the control group. Pure-tone audiograms were obtained for all children, and hearing levels and air-bone gaps were measured. Air-bone gap measurements in the control group ranged from 5.50 to 14.50 decibels (dB), and in the study group they were between 5.00 and 24.00 dB. In the study group, 14 (43.8%) children had slight CHL, and the remaining 18 (56.2%) children had normal hearing levels. In the control group, all of the children had normal hearing levels. Hearing levels and air-bone gaps were greater in the study group than the control group. This study showed that children with a narrowed maxilla and deep palatal vault may have slight CHL. Therefore, the onset of CHL should be followed with hearing screening programs.

  16. Kinetic Study of the Chemical Vapor Deposition of Tantalum in Long Narrow Channels

    DEFF Research Database (Denmark)

    Mugabi, James Atwoki; Eriksen, Søren; Petrushina, Irina

    2016-01-01

    A kinetic study of the chemical vapor deposition of tantalum in long narrow channels is done to optimize the industrial process for the manufacture of tantalum coated plate heat exchangers. The developed model fits well at temperatures between 750 and 850 °C, and in the pressure range of25–990 mbar....... According to the model, the predominant tantalum growth species is TaCl3. The temperature is shown to have a pronounced effect onthe morphology and rate of deposition of the tantalum and an apparent change in deposition mechanism occurs between 850–900 °C, resulting in the deposition rate at 900 °C being...

  17. Study of natural convection characteristics in a narrow annular gap in (Part 1)

    International Nuclear Information System (INIS)

    Narahara, Nobuyuki; Uotani, Masaki; Kinoshita, Izumi

    1986-01-01

    To clarify the characteristics of natural convection in a narrow annular gap at the roof-slab penetrations in pool-type LMFBR, preliminary and visualization experiments were carried out. The results are summarized as follows. (1) In the preliminary experiment having the upper and bottom closed annular space nondimensional circumferential temperature difference increases with gap width decreasing, and decreses with Rayleigh number increasing at the range of rayleigh number 10 10 to 10 11 . (2) In the visualization experiment, which consists the upper and bottom closed annular space type apparatus and the upper-closed bottom-open type apparatus, flow pattern and its effect at temperature distribution are clarified. (author)

  18. The patient dose survey and dose reduction in diagnostic radiology

    International Nuclear Information System (INIS)

    Dang Thanh Luong; Duong Van Vinh; Ha Ngoc Thach

    2000-01-01

    This paper presented the results of the patient dose survey in some hospitals in Hanoi from 1995 to 1997. The main investigated types of the X-ray examination were: Chest PA, LAT; Skull PA/AP, LAT; Lumbar spine AP, LAT; and Pelvis AP. The fluctuation of the entrance surface doses (ESD) was too large, even in the same type of X-ray examination and X-ray facility. It was found that the ratio of maximum and minimum ESD were ranged from 1.5 to 18. The mean values of ESD for chest and skull were higher than CEC recommended values, while the mean values of lumbar spine and pelvis were smaller than that of CEC recommended values. The result of dose intercomparison was also reported. Some methods of dose reduction were applied for improving the patient dose in X-ray departments such as a high kV technique, high sensitive screen-film combination. (author)

  19. Extrinsic stretching narrowing and anterior indentation of the rectosigmoid junction

    International Nuclear Information System (INIS)

    Schulman, A.; Fataar, S.

    1979-01-01

    Thirty-five cases of extrinsic narrowing or anterior indentation of the rectosigmoid junction (RSJ) have been studied. The RSJ lies directly behind the pouch of Douglas which is a favoured site for peritoneal metastasis, abscess and endometriosis. Any space-occupying lesion of sufficient size at this site will indent the anterior aspects of the RSJ. Causes include distension or tumour of the ileum or sigmoid colon, gross ascites (when the patient is erect), and tumours below the pelvic peritonium, such as gynaecological neoplasm and internal iliac artery aneurysm. When a desmoplastic metastasis in the pouch of Douglas infiltrates the outer layers of the RSJ, the fibrosis produces an eccentric shortening on its anterior aspect, which in turn causes a pleating of the mucosa with the folds radiating towards the shortened area. This is also seen with primary pelvic carcinomas directly adherent to the rectum, endometriosis with repeated bleeding and increasing eccentric, submucosal fibrosis, and chronic abscess in the pouch of Douglas. Not all extrinsic narrowing of the RSJ are pathological. One case of anterior indentation followed operation for rectal prolapse. Ten additional cases showed narrowing due to a technical artefact air-distended colon rising into the upper abdomen to cause stretching at the RSJ. As with ascites, this narrowing due to 'high-rise sigmoid' disappeared when the patients became recumbent and the colonic air redistributed. (author)

  20. Efficacy of a dose range of simulated sunlight exposures in raising vitamin D status in South Asian adults: implications for targeted guidance on sun exposure.

    Science.gov (United States)

    Farrar, Mark D; Webb, Ann R; Kift, Richard; Durkin, Marie T; Allan, Donald; Herbert, Annie; Berry, Jacqueline L; Rhodes, Lesley E

    2013-06-01

    Vitamin D is essential for bone health, and cutaneous synthesis is an important source. South Asians cannot attain adequate amounts of vitamin D by following general recommendations on summer sunlight exposure at northerly latitudes, and increased exposure may be appropriate for improving their vitamin D status. We examined the efficacy of a dose range of simulated summer sunlight exposures in raising vitamin D status in UK adults of South Asian ethnicity. In a dose-response study, healthy adults of South Asian ethnicity (n = 60; 20-60 y old) received 1 of 6 ultraviolet exposures ranging from 0.65 to 3.9 standard erythema doses (SEDs), which were equivalent to 15-90 min unshaded noontime summer sunlight at 53.5°N (Manchester, United Kingdom), 3 times/wk for 6 wk, while wearing casual clothes that revealed a 35% skin area. Serum 25-hydroxyvitamin D [25(OH)D] was measured weekly, and dietary vitamin D was estimated. At baseline, all completing participants (n = 51) were vitamin D insufficient [25(OH)D concentrations 10 ng/mL. Targeted guidance on sunlight exposure could usefully enhance vitamin D status to avoid deficiency [25(OH)D concentration >10 ng/mL] in South Asians living at latitudes distant from the equator. This trial was registered at the ISRCTN Register (www.isrctn.org) as 07565297.

  1. Application of monomer/polymer gel dosimetry to study the effects of tissue inhomogeneities on intensity-modulated radiation therapy (IMRT) dose distributions.

    Science.gov (United States)

    Vergote, Koen; De Deene, Yves; Claus, Filip; De Gersem, Werner; Van Duyse, Bart; Paelinck, Leen; Achten, Eric; De Neve, Wilfried; De Wagter, Carlos

    2003-04-01

    When planning an intensity-modulated radiation therapy (IMRT) treatment in a heterogeneous region (e.g. the thorax), the dose computation algorithm of a treatment planning system may need to account for these inhomogeneities in order to obtain a reliable prediction of the dose distribution. An accurate dose verification technique such as monomer/polymer gel dosimetry is suggested to verify the outcome of the planning system. The effects of low-density structures: (a) on narrow high-energy (18 MV) photon beams; and (b) on a class-solution IMRT treatment delivered to a thorax phantom have been examined using gel dosimetry. The used phantom contained air cavities that could be filled with water to simulate a homogeneous or heterogeneous configuration. The IMRT treatment for centrally located lung tumors was delivered on both cases, and gel derived dose maps were compared with computations by both the GRATIS and Helax-TMS planning system. Dose rebuildup due to electronic disequilibrium in a narrow photon beam is demonstrated. The gel measurements showed good agreement with diamond detector measurements. Agreement between measured IMRT dose maps and dose computations was demonstrated by several quantitative techniques. An underdosage of the planning target volume (PTV) was revealed. The homogeneity of the phantom had only a minor influence on the dose distribution in the PTV. An expansion of low-level isodoses in the lung volume was predicted by collapsed cone computations in the heterogeneous case. For the class-solution described, the dose in centrally located mediastinal tumors can be computed with sufficient accuracy, even when neglecting the lower lung density. Polymer gel dosimetry proved to be a valuable technique to verify dose calculation algorithms for IMRT in 3D in heterogeneous configurations.

  2. Field size and dose distribution of electron beam

    International Nuclear Information System (INIS)

    Kang, Wee Saing

    1980-01-01

    The author concerns some relations between the field size and dose distribution of electron beams. The doses of electron beams are measured by either an ion chamber with an electrometer or by film for dosimetry. We analyzes qualitatively some relations; the energy of incident electron beams and depths of maximum dose, field sizes of electron beams and depth of maximum dose, field size and scatter factor, electron energy and scatter factor, collimator shape and scatter factor, electron energy and surface dose, field size and surface dose, field size and central axis depth dose, and field size and practical range. He meets with some results. They are that the field size of electron beam has influence on the depth of maximum dose, scatter factor, surface dose and central axis depth dose, scatter factor depends on the field size and energy of electron beam, and the shape of the collimator, and the depth of maximum dose and the surface dose depend on the energy of electron beam, but the practical range of electron beam is independent of field size

  3. Early changes of cortical blood flow, brain temperature and electrical activity after whole-body irradiation of the monkey (Macaca fascicularis) (dose range: 3-20 Gy)

    International Nuclear Information System (INIS)

    Court, L.; Gourmelon, P.; Mestries, J.C.

    1987-02-01

    A polyparametric investigation was carried out on 31 monkeys chronically wearing bioinstrumentation allowing to get and process simultaneously local brain blood flow, cerebral temperature, and energies in various frequency bands of the brain electrical activity. This method, which supplied data during several consecutive days, made it possible to study both the biological rhythms at the level of the various parameters, and their fast variations. The effects of whole-body gamma or neutron-gamma irradiation were studied in the 3-20 Gy dose range. Immediate changes after exposure demonstrated different radiosensitivities at the level of the rhythms of the various parameters, and/or their recovery, as well as dose-effect relationships [fr

  4. Unsynchronized scanning with a low-cost laser range finder for real-time range imaging

    Science.gov (United States)

    Hatipoglu, Isa; Nakhmani, Arie

    2017-06-01

    Range imaging plays an essential role in many fields: 3D modeling, robotics, heritage, agriculture, forestry, reverse engineering. One of the most popular range-measuring technologies is laser scanner due to its several advantages: long range, high precision, real-time measurement capabilities, and no dependence on lighting conditions. However, laser scanners are very costly. Their high cost prevents widespread use in applications. Due to the latest developments in technology, now, low-cost, reliable, faster, and light-weight 1D laser range finders (LRFs) are available. A low-cost 1D LRF with a scanning mechanism, providing the ability of laser beam steering for additional dimensions, enables to capture a depth map. In this work, we present an unsynchronized scanning with a low-cost LRF to decrease scanning period and reduce vibrations caused by stop-scan in synchronized scanning. Moreover, we developed an algorithm for alignment of unsynchronized raw data and proposed range image post-processing framework. The proposed technique enables to have a range imaging system for a fraction of the price of its counterparts. The results prove that the proposed method can fulfill the need for a low-cost laser scanning for range imaging for static environments because the most significant limitation of the method is the scanning period which is about 2 minutes for 55,000 range points (resolution of 250x220 image). In contrast, scanning the same image takes around 4 minutes in synchronized scanning. Once faster, longer range, and narrow beam LRFs are available, the methods proposed in this work can produce better results.

  5. Patient radiation dose in conventional and xerographic cephalography

    International Nuclear Information System (INIS)

    Copley, R.L.; Glaze, S.A.; Bushong, S.C.; West, D.C.

    1979-01-01

    A comparison of the radiation doses for xeroradiographic and conventional film screen cephalography was made. Alderson tissue-equivalent phantoms were used for patient simulation. An optimum technique in terms of patient dose and image quality indicated that the dose for the Xerox process ranged from five to eleven times greater than that for the conventional process for entrance and exit exposures, respectively. This dose, however, falls within an acceptable range for other dental and medical radiation doses. It is recommended that conventional cephalography be used for routine purposes and that xeroradiography be reserved for situations requiring the increased image quality that the process affords

  6. Naltrexone and human eating behavior: a dose-ranging inpatient trial in moderately obese men.

    Science.gov (United States)

    Maggio, C A; Presta, E; Bracco, E F; Vasselli, J R; Kissileff, H R; Pfohl, D N; Hashim, S A

    1985-06-01

    To investigate the effects of the long-acting opiate antagonist naltrexone on spontaneous human eating behavior, eight moderately obese male paid volunteers were housed in a hospital metabolic unit for 28 days and offered palatable foods ad lib by a platter service method. Under double-blind conditions, equally divided doses of 100, 200 and 300 mg naltrexone, or an acetaminophen placebo, were administered twice daily in tablet form for 3-day periods each, according to a Latin Square design. The doses of naltrexone resulted in decreases of daily caloric intake from placebo level, but these reductions were neither statistically significant nor dose-related. When the averaged effects of the doses were compared to placebo, five subjects showed intake reductions but the overall intake reduction of 301.5 +/- 198.1 kcal/day (mean +/- SEM) was not statistically significant. Naltrexone administration failed to selectively alter intakes of individual meals and snacks or macronutrient consumption patterns. During active drug periods, subjects lost 0.62 +/- 0.22 lb over 3 days, while during the placebo period, subjects gained 0.46 +/- 0.68 lb. However, there was no reliable change of basal metabolic rate as a function of naltrexone administration. The present results, which indicate that naltrexone administration is relatively ineffective in reducing food intake and inducing body weight loss in obese humans, are thus in contrast with reports that administration of opiate antagonist agents promote significant reductions of food intake and attenuations of body weight gain in experimental animals.

  7. Radiation dose to trabecular bone marrow stem cells from 3H, 14C and selected α-emitters incorporated in a bone remodeling compartment

    International Nuclear Information System (INIS)

    Nie Huiling; Richardson, Richard B

    2009-01-01

    A Monte Carlo simulation of repeated cubic units representing trabecular bone cavities in adult bone was employed to determine absorbed dose fractions evaluated for 3 H, 14 C and a set of α-emitters incorporated within a bone remodeling compartment (BRC). The BRC consists of a well-oxygenated vascular microenvironment located within a canopy of bone-lining cells. The International Commission on Radiological Protection (ICRP) considers that an important target for radiation-induced bone cancer is the endosteum marrow layer adjacent to bone surface where quiescent bone stem cells reside. It is proposed that the active stem cells and progenitor cells located above the BRC canopy, the 'BRC stem cell niche', is a more important radiation-induced cancer target volume. Simulation results from a static model, where no remodeling occurs, indicate that the mean dose from bone and bone surface to the 50 μm quiescent bone stem cell niche, the current ICRP target, was substantially lower (two to three times lower) than that to the narrower and hypoxic 10 μm endosteum for 3 H, 14 C and α-particles with energy range 0.5-10 MeV. The results from a dynamic model indicate that the temporal α-radiation dose to active stem/progenitor cells located in the BRC stem cell niche from the material incorporated in and buried by forming bone was 9- to 111-fold greater than the dose to the quiescent bone stem cell niche. This work indicates that the remodeling portion of the bone surface, rather than the quiescent (endosteal) surface, has the greatest risk of radiation-induced bone cancer, particularly from short-range radiation, due to the elevated dose and the radiosensitizing oxygen effect.

  8. Widely tunable single-/dual-wavelength fiber lasers with ultra-narrow linewidth and high OSNR using high quality passive subring cavity and novel tuning method.

    Science.gov (United States)

    Feng, Ting; Ding, Dongliang; Yan, Fengping; Zhao, Ziwei; Su, Hongxin; Yao, X Steve

    2016-08-22

    High stability single- and dual-wavelength compound cavity erbium-doped fiber lasers (EDFLs) with ultra-narrow linewidth, high optical signal to noise ratio (OSNR) and widely tunable range are demonstrated. Different from using traditional cascaded Type-1/Type-2 fiber rings as secondary cavities, we nest a Type-1 ring inside a Type-2 ring to form a passive subring cavity to achieve single-longitudinal-mode (SLM) lasing with ultra-narrow linewidth for the first time. We also show that the SLM lasing stability can be further improved by inserting a length of polarization maintaining fiber in the Type-2 ring. Using a uniform fiber Bragg grating (FBG) and two superimposed FBGs as mode restricting elements, respectively, we obtain a single-wavelength EDFL with a linewidth as narrow as 715 Hz and an OSNR as high as 73 dB, and a dual-wavelength EDFL with linewidths less than 1 kHz and OSNRs higher than 68 dB for both lasing wavelengths. Finally, by employing a novel self-designed strain adjustment device capable of applying both the compression and tension forces to the FBGs for wavelength tuning, we achieve the tuning range larger than 10 nm for both of the EDFLs.

  9. Dose-ranging pilot randomized trial of amino acid mixture combined with physical activity promotion for reducing abdominal fat in overweight adults

    Directory of Open Access Journals (Sweden)

    Sasai H

    2017-07-01

    Full Text Available Hiroyuki Sasai,1–3,* Keisuke Ueda,4,5,* Takehiko Tsujimoto,6,7 Hiroyuki Kobayashi,1 Chiaki Sanbongi,4 Shuji Ikegami,4 Yoshio Nakata1 1Faculty of Medicine, University of Tsukuba, Tsukuba, Ibaraki, 2Japan Society for the Promotion of Science, Chiyoda, Tokyo, 3Department of Life Sciences, Graduate School of Arts and Sciences, The University of Tokyo, Meguro, Tokyo, 4Food Science Research Laboratories, Meiji Co., Ltd., Odawara, Kanagawa, 5Graduate School of Comprehensive Human Sciences, 6Faculty of Health and Sport Sciences, University of Tsukuba, Tsukuba, Ibaraki, 7Faculty of Human Sciences, Shimane University, Matsue, Shimane, Japan *These authors contributed equally to this work Objective: The objective of this study was to determine the effective dose of an amino acid mixture comprising arginine, alanine, and phenylalanine combined with physical activity promotion in reducing abdominal fat among overweight adults.Methods: A 12-week randomized, double-blind, placebo-controlled, dose-ranging, pilot trial was conducted in Mito, Japan, from January through April 2016, and the data were analyzed from May through November 2016. The study participants were 35 overweight adults, aged 20–64 years, with no regular exercise habit. Participants were randomly assigned to high-dose (3,000 mg/d, n=9, medium-dose (1,500 mg/d, n=9, low-dose (750 mg/d, n=8, or placebo (0 mg/d, n=9 groups, and the test beverage containing the amino acid mixture or placebo was administered for 12 weeks. All participants maintained a physically active lifestyle during the study period through monthly physical activity promotion sessions and smartphone-based self-monitoring with wearable trackers. Primary outcomes were changes in abdominal total, subcutaneous, and visceral fat areas, assessed by computed tomography.Results: Of the 35 enrolled participants, 32 completed the 12-week follow-up visit. The intention-to-treat analysis revealed that the changes in abdominal total fat

  10. Dose-rate and the reciprocity law: TL response of Ge-doped SiO2 optical fibers at therapeutic radiation doses

    International Nuclear Information System (INIS)

    Abdul Rahman, A.T.; Nisbet, A.; Bradley, D.A.

    2011-01-01

    An investigation has been made on commercially available Ge-doped SiO 2 optical fibers as a novel thermoluminescence system for radiotherapy dosimetry. This dosimeter has previously been shown by the group to provide sensitive dosimetry over a wide range of electron and photon dose, suitable for the needs of radiotherapy. In addition the optical fiber offers small physical size (125 μm diameter) and hence high spatial resolution. The reciprocity between thermoluminescence (TL) yield of Ge-doped SiO 2 optical fibers and dose has been investigated for fixed radiation dose for a range of photon and electron dose rates. For electron beams of nominal energies in the range of 9-20 MeV, we have investigated the TL response of these fibers for dose rates between 100 and 1000 cGy min -1 . For photon beams of nominal energies in the range of 6-15 MV, we have used dose rates of 100-600 cGy min -1 . Reproducibility and fading at fixed absorbed dose (3 Gy) and dose rate for the optical fibers were also investigated. At fixed dose rates, the TL optical fibers were found to produce a flat TL yield within 4% (1σ) and 3% (1σ) for electron and photon beams, respectively. The optical fibers demonstrated good reproducibility (±1.5%), low residual signal for a readout temperature of 300 o C and negligible fading. A weak dependence on dose-rate has been observed in the range of 3.4-3.9% for electrons (with an associated uncertainty of 4%) and 2.4-2.9% for photons (with an associated uncertainty of <4%). For electron and photon energies we note a consistent trend towards lower response in the TL yield of between 3.4-3.9% and 2.4-2.7%, respectively, at the higher dose rates in comparison with the response at lower dose rates. In addition we note an appreciable systematic energy dependence for both electron and photon beams. It is important to take such factors into account for providing precise and accurate radiotherapy dosimetry. It is also apparent that the optical fibers can be re

  11. Influence of dose and dose rate on the physical properties of commercial papers commonly used in libraries and archives

    International Nuclear Information System (INIS)

    Area, María C.; Calvo, Ana M.; Felissia, Fernando E.; Docters, Andrea; Miranda, María V.

    2014-01-01

    The aim of this study was to evaluate the effects of dose and dose rate of gamma irradiation on the physical properties of commercial papers commonly used in libraries and archives to optimize the irradiation conditions. Three different brands of paper of different fiber compositions were treated, using a 3 2 factorial design with four replicates of the center point, with doses ranging from 2 to 11 kGy and dose rates between 1 and 11 kGy/h. Chemical, mechanical and optical properties were determined on the samples. With some differences between the different kinds of papers, tensile strength, elongation, TEA, and air resistance were in general, unaffected by the treatment. The minimum loss of tear resistance and brightness were obtained with doses in the range 4–6 kGy at any dose rate for all three kinds of paper. These conditions are ideal to remove insects and sufficient to eliminate fungus. - Highlights: • Gamma irradiation is a valid option to remove mold from books and documents. • We studied the effect of irradiation dose and dose rate on the physical properties of papers. • We found an optimum combination of dose and dose rate

  12. A protein?dye hybrid system as a narrow range tunable intracellular pH sensor? ?Electronic supplementary information (ESI) available: Figures depicting various photophysical properties, cytotoxicity studies and confocal fluorescence images. See DOI: 10.1039/c6sc02659a Click here for additional data file.

    OpenAIRE

    Anees, Palapuravan; Sudheesh, Karivachery V.; Jayamurthy, Purushothaman; Chandrika, Arunkumar R.; Omkumar, Ramakrishnapillai V.; Ajayaghosh, Ayyappanpillai

    2016-01-01

    Accurate monitoring of pH variations inside cells is important for the early diagnosis of diseases such as cancer. Even though a variety of different pH sensors are available, construction of a custom-made sensor array for measuring minute variations in a narrow biological pH window, using easily available constituents, is a challenge. Here we report two-component hybrid sensors derived from a protein and organic dye nanoparticles whose sensitivity range can be tuned by choosing different rat...

  13. Cervical spinal canal narrowing in idiopathic syringomyelia

    International Nuclear Information System (INIS)

    Struck, Aaron F.; Carr, Carrie M.; Shah, Vinil; Hesselink, John R.; Haughton, Victor M.

    2016-01-01

    The cervical spine in Chiari I patient with syringomyelia has significantly different anteroposterior diameters than it does in Chiari I patients without syringomyelia. We tested the hypothesis that patients with idiopathic syringomyelia (IS) also have abnormal cervical spinal canal diameters. The finding in both groups may relate to the pathogenesis of syringomyelia. Local institutional review boards approved this retrospective study. Patients with IS were compared to age-matched controls with normal sagittal spine MR. All subjects had T1-weighted spin-echo (500/20) and T2-weighted fast spin-echo (2000/90) sagittal cervical spine images at 1.5 T. Readers blinded to demographic data and study hypothesis measured anteroposterior diameters at each cervical level. The spinal canal diameters were compared with a Mann-Whitney U test. The overall difference was assessed with a Friedman test. Seventeen subjects were read by two reviewers to assess inter-rater reliability. Fifty IS patients with 50 age-matched controls were studied. IS subjects had one or more syrinxes varying from 1 to 19 spinal segments. Spinal canal diameters narrowed from C1 to C3 and then enlarged from C5 to C7 in both groups. Diameters from C2 to C4 were narrower in the IS group (p < 0.005) than in controls. The ratio of the C3 to the C7 diameters was also smaller (p = 0.004) in IS than controls. Collectively, the spinal canal diameters in the IS were significantly different from controls (Friedman test p < 0.0001). Patients with IS have abnormally narrow upper and mid cervical spinal canal diameters and greater positive tapering between C3 and C7. (orig.)

  14. Cervical spinal canal narrowing in idiopathic syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Struck, Aaron F. [Massachusetts General Hospital, Department of Neurology, Boston, MA (United States); Carr, Carrie M. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Shah, Vinil [University of California San Francisco, Department of Radiology, San Francisco, CA (United States); Hesselink, John R. [University of California San Diego, Department of Radiology, San Diego, CA (United States); Haughton, Victor M. [University of Wisconsin, Department of Radiology, Madison, WI (United States)

    2016-08-15

    The cervical spine in Chiari I patient with syringomyelia has significantly different anteroposterior diameters than it does in Chiari I patients without syringomyelia. We tested the hypothesis that patients with idiopathic syringomyelia (IS) also have abnormal cervical spinal canal diameters. The finding in both groups may relate to the pathogenesis of syringomyelia. Local institutional review boards approved this retrospective study. Patients with IS were compared to age-matched controls with normal sagittal spine MR. All subjects had T1-weighted spin-echo (500/20) and T2-weighted fast spin-echo (2000/90) sagittal cervical spine images at 1.5 T. Readers blinded to demographic data and study hypothesis measured anteroposterior diameters at each cervical level. The spinal canal diameters were compared with a Mann-Whitney U test. The overall difference was assessed with a Friedman test. Seventeen subjects were read by two reviewers to assess inter-rater reliability. Fifty IS patients with 50 age-matched controls were studied. IS subjects had one or more syrinxes varying from 1 to 19 spinal segments. Spinal canal diameters narrowed from C1 to C3 and then enlarged from C5 to C7 in both groups. Diameters from C2 to C4 were narrower in the IS group (p < 0.005) than in controls. The ratio of the C3 to the C7 diameters was also smaller (p = 0.004) in IS than controls. Collectively, the spinal canal diameters in the IS were significantly different from controls (Friedman test p < 0.0001). Patients with IS have abnormally narrow upper and mid cervical spinal canal diameters and greater positive tapering between C3 and C7. (orig.)

  15. Narrow plasmon resonances enabled by quasi-freestanding bilayer epitaxial graphene

    Science.gov (United States)

    Daniels, Kevin M.; Jadidi, M. Mehdi; Sushkov, Andrei B.; Nath, Anindya; Boyd, Anthony K.; Sridhara, Karthik; Drew, H. Dennis; Murphy, Thomas E.; Myers-Ward, Rachael L.; Gaskill, D. Kurt

    2017-06-01

    Exploiting the underdeveloped terahertz range (~1012-1013 Hz) of the electromagnetic spectrum could advance many scientific fields (e.g. medical imaging for the identification of tumors and other biological tissues, non-destructive evaluation of hidden objects or ultra-broadband communication). Despite the benefits of operating in this regime, generation, detection and manipulation have proven difficult, as few materials have functional interactions with THz radiation. In contrast, graphene supports resonances in the THz regime through structural confinement of surface plasmons, which can lead to enhanced absorption. In prior work, the achievable plasmon resonances in such structures have been limited by multiple electron scattering mechanisms (i.e. large carrier scattering rates) which greatly broaden the resonance (>100 cm-1 3 THz). We report the narrowest room temperature Drude response to-date, 30 cm-1 (0.87 THz), obtained using quasi-free standing bilayer epitaxial graphene (QFS BLG) synthesized on (0 0 0 1)6H-SiC. This narrow response is due to a 4-fold increase in carrier mobility and improved thickness and electronic uniformity of QFS BLG. Moreover, QFS BLG samples patterned into microribbons targeting 1.8-5.7 THz plasmon resonances also exhibit low scattering rates (37-53 cm-1). Due to the improved THz properties of QFS BLG, the effects of e-beam processing on carrier scattering rates was determined and we found that fabrication conditions can be tuned to minimize the impact on optoelectronic properties. In addition, electrostatic gating of patterned QFS BLG shows narrow band THz amplitude modulation. Taken together, these properties of QFS BLG should facilitate future development of THz optoelectronic devices for monochromatic applications.

  16. Analysis of patient CT dose data using virtualdose

    Science.gov (United States)

    Bennett, Richard

    X-ray computer tomography has many benefits to medical and research applications. Recently, over the last decade CT has had a large increase in usage in hospitals and medical diagnosis. In pediatric care, from 2000 to 2006, abdominal CT scans increased by 49 % and chest CT by 425 % in the emergency room (Broder 2007). Enormous amounts of effort have been performed across multiple academic and government groups to determine an accurate measure of organ dose to patients who undergo a CT scan due to the inherent risks with ionizing radiation. Considering these intrinsic risks, CT dose estimating software becomes a necessary tool that health care providers and radiologist must use to determine many metrics to base the risks versus rewards of having an x-ray CT scan. This thesis models the resultant organ dose as body mass increases for patients with all other related scan parameters fixed. In addition to this,this thesis compares a modern dose estimating software, VirtualDose CT to two other programs, CT-Expo and ImPACT CT. The comparison shows how the software's theoretical basis and the phantom they use to represent the human body affect the range of results in organ dose. CT-Expo and ImPACT CT dose estimating software uses a different model for anatomical representation of the organs in the human body and the results show how that approach dramatically changes the outcome. The results categorizes four datasets as compared to the three software types where the appropriate phantom was available. Modeling was done to simulate chest abdominal pelvis scans and whole body scans. Organ dose difference versus body mass index shows as body mass index (BMI) ranges from 23.5 kg/m 2 to 45 kg/m2 the amount of organ dose also trends a percent change from -4.58 to -176.19 %. Comparing organ dose difference with increasing x-ray tube potential from 120 kVp to 140 kVp the percent change in organ dose increases from 55 % to 65 % across all phantoms. In comparing VirtualDose to CT

  17. Application of narrow-band television to industrial and commercial communications

    Science.gov (United States)

    Embrey, B. C., Jr.; Southworth, G. R.

    1974-01-01

    The development of narrow-band systems for use in space systems is presented. Applications of the technology to future spacecraft requirements are discussed along with narrow-band television's influence in stimulating development within the industry. The transferral of the technology into industrial and commercial communications is described. Major areas included are: (1) medicine; (2) education; (3) remote sensing for traffic control; and (5) weather observation. Applications in data processing, image enhancement, and information retrieval are provided by the combination of the TV camera and the computer.

  18. Evaluation of the 'dose of the day' for IMRT prostate cancer patients derived from portal dose measurements and cone-beam CT

    International Nuclear Information System (INIS)

    Zijtveld, Mathilda van; Dirkx, Maarten; Breuers, Marcel; Kuipers, Ruud; Heijmen, Ben

    2010-01-01

    Purpose: High geometrical and dosimetrical accuracies are required for radiotherapy treatments where IMRT is applied in combination with narrow treatment margins in order to minimize dose delivery to normal tissues. As an overall check, we implemented a method for reconstruction of the actually delivered 3D dose distribution to the patient during a treatment fraction, i.e., the 'dose of the day'. In this article results on the clinical evaluation of this concept for a group of IMRT prostate cancer patients are presented. Materials and methods: The actual IMRT fluence maps delivered to a patient were derived from measured EPID-images acquired during treatment using a previously described iterative method. In addition, the patient geometry was obtained from in-room acquired cone-beam CT images. For dose calculation, a mapping of the Hounsfield Units from the planning CT was applied. With the fluence maps and the modified cone-beam CT the 'dose of the day' was calculated. The method was validated using phantom measurements and evaluated clinically for 10 prostate cancer patients in 4 or 5 fractions. Results: The phantom measurements showed that the delivered dose could be reconstructed within 3%/3 mm accuracy. For prostate cancer patients, the isocenter dose agreed within -0.4 ± 1.0% (1 SD) with the planned value, while for on average 98.1% of the pixels within the 50% isodose surface the actually delivered dose agreed within 3% or 3 mm with the planned dose. For most fractions, the dose coverage of the prostate volume was slightly deteriorated which was caused by small prostate rotations and small inaccuracies in fluence delivery. The dose that was delivered to the rectum remained within the constraints used during planning. However, for two patients a large degrading of the dose delivery was observed in two fractions. For one patient this was related to changes in rectum filling with respect to the planning CT and for the other to large intra-fraction motion during

  19. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  20. High thermal stability solution-processable narrow-band gap molecular semiconductors.

    Science.gov (United States)

    Liu, Xiaofeng; Hsu, Ben B Y; Sun, Yanming; Mai, Cheng-Kang; Heeger, Alan J; Bazan, Guillermo C

    2014-11-19

    A series of narrow-band gap conjugated molecules with specific fluorine substitution patterns has been synthesized in order to study the effect of fluorination on bulk thermal stability. As the number of fluorine substituents on the backbone increase, one finds more thermally robust bulk structures both under inert and ambient conditions as well as an increase in phase transition temperatures in the solid state. When integrated into field-effect transistor devices, the molecule with the highest degree of fluorination shows a hole mobility of 0.15 cm(2)/V·s and a device thermal stability of >300 °C. Generally, the enhancement in thermal robustness of bulk organization and device performance correlates with the level of C-H for C-F substitution. These findings are relevant for the design of molecular semiconductors that can be introduced into optoelectronic devices to be operated under a wide range of conditions.

  1. Safety, immunogenicity and dose ranging of a new Vi-CRM₁₉₇ conjugate vaccine against typhoid fever: randomized clinical testing in healthy adults.

    Directory of Open Access Journals (Sweden)

    Pierre van Damme

    Full Text Available Typhoid fever causes more than 21 million cases of disease and 200,000 deaths yearly worldwide, with more than 90% of the disease burden being reported from Asia. Epidemiological data show high disease incidence in young children and suggest that immunization programs should target children below two years of age: this is not possible with available vaccines. The Novartis Vaccines Institute for Global Health developed a conjugate vaccine (Vi-CRM₁₉₇ for infant vaccination concomitantly with EPI vaccines, either starting at 6 weeks with DTP or at 9 months with measles vaccine. We report the results from a Phase 1 and a Phase 2 dose ranging trial with Vi-CRM₁₉₇ in European adults.Following randomized blinded comparison of single vaccination with either Vi-CRM₁₉₇ or licensed polysaccharide vaccines (both containing 25·0 µg of Vi antigen, a randomised observer blinded dose ranging trial was performed in the same center to compare three concentrations of Vi-CRM₁₉₇ (1·25 µg, 5·0 µg and 12·5 µg of Vi antigen with the polysaccharide vaccine.All vaccines were well tolerated. Compared to the polysaccharide vaccine, Vi-CRM₁₉₇ induced a higher incidence of mild to moderate short lasting local pain. All Vi-CRM₁₉₇ formulations induced higher Vi antibody levels compared to licensed control, with clear dose response relationship.Vi-CRM₁₉₇ did not elicit safety concerns, was highly immunogenic and is therefore suitable for further clinical testing in endemic populations of South Asia.ClinicalTrials.gov NCT01123941 NCT01193907.

  2. Dimethyl sulfoxyde diethyl fumarate solution for high dose dosimetry

    International Nuclear Information System (INIS)

    Al-Kassiri, H.; Kattan, M.; Daher, Y.

    2007-06-01

    Dosimetric characterization of diethyl fumarate DEF in dimethyl sulfoxyde DMSO solution has been studied spectrophotometrically for possible application at high dose radiation dosimetry in the range (0-225 kGy). The absorption spectra of irradiated solution showed broad absorption bands between (325-400 nm) with a shoulder at 332 nm. The absorption increases as the dose is increased. Absorbance at 332 nm were measured and plotted against absorbed dose. Linear relationship and good response were found between absorbed dose and absorbance of 20% DEF concentration in the range (0-225 kGy) at the wave length, and linearity up to 250 kGy of absorbance at 332 nm .Good dose rate independence was observed in the range (14-33 kGy/h). The effect of post irradiation storage in darkness and indirect daylight conditions were not found to influence the absorption up to 700 h after irradiation. The effect of irradiation temperature within the range (0 to 60 centigrade degree) on the dosimetry performance was discussed.(author)

  3. Paediatric doses from diagnostic radiology in Victoria

    International Nuclear Information System (INIS)

    Boal, T.J.; Cardillo, I.; Einsiedel, P.F.

    1998-01-01

    This study examines doses to paediatric patients from diagnostic radiology. Measurements were made at 29 hospitals and private radiology practices in the state of Victoria. Entrance skin doses in air were measured for the exposure factors used by hospital radiology departments and private radiology practices for a standard size 1, 5, 10 and 15 year old child, for the following procedures: chest AP/PA, lat; abdomen AP; pelvis AP; lumbar spine AP, lat; and skull AP, lat. There was a large range of doses for each particular procedure and age group. Factors contributing to the range of doses were identified. Guidance levels for paediatric radiology based on the third quartile value of the skin entrance doses have been recommended and are compared with guidance levels. Copyright (1998) Australasian Physical and Engineering Sciences in Medicine

  4. Narrowing sex differences in life expectancy: regional variations, 1971-1991

    Directory of Open Access Journals (Sweden)

    Frank Trovato

    2001-12-01

    Full Text Available A number of industrialized nations have recently experienced some degrees of constriction in their long-standing sex differentials in life expectancy at birth. In this study we examine this phenomenon in the context of Canada’s regions between 1971 and 1991: Atlantic (Newfoundland, Nova Scotia, New Brunswick, Prince Edward Island; Quebec, Ontario, and the West (Manitoba, Saskatchewan, Alberta, British Columbia, Yukon and Northwest Territories. Decomposition analysis based on multiple decrement life tables is applied to address three questions: (1 Are there regional differentials in the degree of narrowing in the sex gap in life expectancy? (2 What is the relative contribution of major causes of death to observed sex differences in average length of life within and across regions? (3 How do the contributions of cause-of-death components vary across regions to either widen or narrow the sex gap in survival? It is shown that the magnitude of the sex gap is not uniform across the regions, though the differences are not large. The most important contributors to a narrowing of the sex gap in life expectancy are heart disease and external types of mortality (i.e., accidents, violence, and suicide, followed by lung cancer and other types of chronic conditions. In substantive terms these results indicate that over time men have been making sufficient gains in these causes of death as to narrow some of the gender gap in overall survival. Regions show similarity in these effects.

  5. High Prevalence of Narrow Angles among Chinese-American Glaucoma and Glaucoma Suspect Patients

    Science.gov (United States)

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    Purpose To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Patients and Methods Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data was collected for gender, age, race (self-declared), refraction (spherical equivalent), intraocular pressure (IOP), gonioscopy and vertical cup-to-disk ratio (CDR). Results Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade ≤2 in three or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the two groups did not differ in terms of gender, refraction, IOP or CDR (all, P≥0.071). In a multivariate model including age, gender and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). Conclusions A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of gender or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed. PMID:19826385

  6. Current algorithms for computed electron beam dose planning

    International Nuclear Information System (INIS)

    Brahme, A.

    1985-01-01

    Two- and sometimes three-dimensional computer algorithms for electron beam irradiation are capable of taking all irregularities of the body cross-section and the properties of the various tissues into account. This is achieved by dividing the incoming broad beams into a number of narrow pencil beams, the penetration of which can be described by essentially one-dimensional formalisms. The constituent pencil beams are most often described by Gaussian, experimentally or theoretically derived distributions. The accuracy of different dose planning algorithms is discussed in some detail based on their ability to take the different physical interaction processes of high energy electrons into account. It is shown that those programs that take the deviations from the simple Gaussian model into account give the best agreement with experimental results. With such programs a dosimetric relative accuracy of about 5% is generally achieved except in the most complex inhomogeneity configurations. Finally, the present limitations and possible future developments of electron dose planning are discussed. (orig.)

  7. High prevalence of narrow angles among Chinese-American glaucoma and glaucoma suspect patients.

    Science.gov (United States)

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data were collected for sex, age, race (self-declared), refraction (spherical equivalent), intraocular pressure, gonioscopy, and vertical cup-to-disk ratio. Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade or = 0.071). In a multivariate model including age, sex, and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of sex or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed.

  8. Retrospective Reconstructions of Active Bone Marrow Dose-Volume Histograms

    International Nuclear Information System (INIS)

    Veres, Cristina; Allodji, Rodrigue S.; Llanas, Damien; Vu Bezin, Jérémi; Chavaudra, Jean; Mège, Jean Pierre; Lefkopoulos, Dimitri; Quiniou, Eric; Deutsh, Eric; Vathaire, Florent de; Diallo, Ibrahima

    2014-01-01

    Purpose: To present a method for calculating dose-volume histograms (DVH's) to the active bone marrow (ABM) of patients who had undergone radiation therapy (RT) and subsequently developed leukemia. Methods and Materials: The study focuses on 15 patients treated between 1961 and 1996. Whole-body RT planning computed tomographic (CT) data were not available. We therefore generated representative whole-body CTs similar to patient anatomy. In addition, we developed a method enabling us to obtain information on the density distribution of ABM all over the skeleton. Dose could then be calculated in a series of points distributed all over the skeleton in such a way that their local density reflected age-specific data for ABM distribution. Dose to particular regions and dose-volume histograms of the entire ABM were estimated for all patients. Results: Depending on patient age, the total number of dose calculation points generated ranged from 1,190,970 to 4,108,524. The average dose to ABM ranged from 0.3 to 16.4 Gy. Dose-volume histograms analysis showed that the median doses (D 50% ) ranged from 0.06 to 12.8 Gy. We also evaluated the inhomogeneity of individual patient ABM dose distribution according to clinical situation. It was evident that the coefficient of variation of the dose for the whole ABM ranged from 1.0 to 5.7, which means that the standard deviation could be more than 5 times higher than the mean. Conclusions: For patients with available long-term follow-up data, our method provides reconstruction of dose-volume data comparable to detailed dose calculations, which have become standard in modern CT-based 3-dimensional RT planning. Our strategy of using dose-volume histograms offers new perspectives to retrospective epidemiological studies

  9. A comparative study of the Si diodes of N type applied to high-dose range dosimetry

    International Nuclear Information System (INIS)

    Pascoalino, Kelly Cristina da Silva; Goncalves, Josemary Angelica Correa; Tobias, Carmen Cecilia Bueno

    2011-01-01

    This work presents the results of the comparative studies of floating-zone (Fz) and magnetic Czochralski (MCz) n-type silicon diodes as gamma dosimeters. The devices were irradiated with gamma rays from 60 Co source, Gammacell 220, at Radiation Technology Center (CTR-IPEN/CNEN-SP) with the dose rate of 2 kGy/h. The results with total absorbed doses of approximately 1 MGy showed that the devices studied are tolerant to radiation damages and then can be used as an online dosimeter in high doses radiation processing. (author)

  10. THE TREATMENT OF OPEN- AND NARROW-ANGLE GLAUCOMA

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... glaucoma will be considered: narrow-angle glaucoma. (acute glaucoma) and ... emotional or a physical crisis. The pain is in the distribu- .... ness, not increased pressure, haunts people suffering from glaucoma'.' The saga of ...

  11. Search for narrow H-gamma resonances in proton-proton collisions at sqrt(s) = 13 TeV

    CERN Document Server

    CMS Collaboration

    2018-01-01

    A search for heavy, narrow-width resonances decaying to a Higgs boson and a photon has been performed in proton-proton collision data corresponding to an integrated luminosity of 35.9 inverse femtobarns, collected with the CMS detector at the LHC at a center-of-mass energy of 13 TeV in 2016. Events in which a photon and a Lorentz-boosted Higgs boson that decays hadronically and reconstructed as a single, large-radius jet are considered, and the photon+jet invariant mass spectrum is analyzed to look for the presence of narrow-width resonances. To increase the sensitivity of the search, events are categorized depending on whether the large-radius jet is consistent with originating from merging of two b quarks. Results in both categories are found to agree with the predictions of the standard model. Upper limits on the production of Higgs+photon resonances are set as a function of resonance mass in the range of $720\\mathrm{-}3250~\\mathrm{GeV}$, representing the most stringent limits to date.

  12. A conceptual framework for managing radiation dose to patients in diagnostic radiology using reference dose levels

    International Nuclear Information System (INIS)

    Almen, Anja; Baath, Magnus

    2016-01-01

    The overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined. The outset of the optimisation process is four stages: providing equipment, establishing methodology, performing examinations and ensuring quality. The optimisation process comprises a series of activities and actions at these stages. The current system of diagnostic reference levels is an activity in the last stage, ensuring quality. The system becomes a reactive activity only to a certain extent engaging the core activity in the radiology department, performing examinations. Three reference dose levels-possible, expected and established-were assigned to the three stages in the optimisation process, excluding ensuring quality. A reasonably achievable dose range is also derived, indicating an acceptable deviation from the established dose level. A reasonable radiation dose for a single patient is within this range. The suggested framework for managing radiation dose should be regarded as one part of the optimisation process. The optimisation process constitutes a variety of complementary activities, where managing radiation dose is only one part. This emphasises the need to take a holistic approach integrating the optimisation process in different clinical activities. (authors)

  13. A Mechanistic Model of Onset of Flow Instability Due to Mergence of Bubble Layers in a Vertical Narrow Rectangular Channel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Juh Yung; Chang, Soon Heung; Jeong, Yong [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    The onset of flow instability (OFI) is the one of important boiling phenomena since it may induce the premature critical heat flux (CHF) at the lowest heat flux level due to sudden flow excursion in a single channel of multichannel configuration. Especially prediction of OFI for narrow rectangular channel is very crucial in relevant to thermal-hydraulic design and safety analysis of open pool-type research reactors (RRs) using plate-type fuels. Based on high speed video (HSV) technique, the authors observed and determined that OFI and the minimum premature CHF in a narrow rectangular channel are induced by abrupt pressure drop fluctuation due to the mergence of facing bubble boundary layers (BLs) on opposite boiling surfaces. In this study, new mechanistic OFI model for narrow rectangular channel heated on both sides has been derived, which satisfies with the real triggering phenomena. Force balance approach was used for modeling of the maximum BLT since the quantity is comparable to the bubble departure diameter. From the validation with OFI database, it was shown that the new model fairly well predicts OFI heat flux for wide range of conditions.

  14. Effect of low dose rate irradiation on doped silica core optical fibers

    International Nuclear Information System (INIS)

    Friebele, E.J.; Askins, C.G.; Gingerich, M.E.

    1984-01-01

    The optical attenuation induced in multimode doped silica core optical fiber waveguides by a year's exposure to low dose rate (1 rad/day) ionizing radiation was studied, allowing a characterization of fibers deployed in these environments and a determination of the permanent induced loss in the waveguides. Variations in the induced attenuation at 0.85 μm have been observed with changes in the dose rate between 1 rad/day and 9000 rads/min. These dose rate dependences have been found to derive directly from the recovery that occurs during the exposure; the recovery data predict little or no dose rate dependence of the damage at 1.3 μm. The low dose rate exposure has been found to induce significant permanent attenuation in the 0.7-1.7-μm spectral region in all fibers containing P in the core, whether doped uniformly across the diameter or constrained to a narrow spike on the centerline. Whereas permanent loss was induced at 0.85 μm in a P-free binary Ge-doped silica core fiber by the year's exposure, virtually no damage was observed at 1.3 μm

  15. Low dose effects detected by micronucleus assay in lymphocytes

    International Nuclear Information System (INIS)

    Koeteles, G.J.; Bojtor, I.; Kubasova, T.; Horvath, G.

    1997-01-01

    The effects of low doses of X-rays between 0.01 and 1 Gy were studied on whole blood samples of various individuals using the cytokinesis-blocked lymphocyte micronucleus assay as an endpoint. The adaptive response could be induced in G 0 cells by 0.01 Gy followed by 1 Gy challenging dose within a time period of 8 hours, in vitro. The probability distribution of micronucleus increments in those samples which had received very low doses in the range 0.01-0.05 Gy proved to be of asymmetrical type (i.e. lognormal) -very likely to the same shape which has been verified for unirradiated (control) population - while the variable turned to be normally distributed at or above 1 Gy. Profound changes have been experienced in the main characteristics of the linear dose - response relationship and in regression parameters, as well, when successively lessened dose ranges were studied toward 0.01 Gy. In the range below ∼ 0.2 Gy the response were found to be unrelated to the absorbed dose. These findings suggest that in (very) low dose range a higher attention should be needed to biological parameters like repair, protective mechanisms and antioxidant capacities, rather than to the absorbed radiation energy only. (author)

  16. Dose assessment of an accidental exposure at IPNS

    International Nuclear Information System (INIS)

    Torres, M.M.C.

    1996-01-01

    Seven different methods were used to estimate the dose rate to a female worker who was accidentally exposed in the neutron PHOENIX beamline at the IPNS. Theoretical and measured entrance dose rates ranged from 550 mrem/min to 2,850 mrem/min. Theoretical estimates were based on a Monte Carlo simulation of a spectrum provided by IPNS (Crawford Spectrum). Dose measurements were made with TLDs on phantoms and with ionization chambers in a water phantom. Estimates of the whole body total effective dose equivalent (TEDE) rate ranged from 5.2 mrem/min to 840 mrem/min. Assumed and measured quality factors ranged from 2.6 to 11.8. Cytogenic analyses of blood samples detected no positive exposure. The recommended TEDE rate was 158 mrem/min. The TEDE was 750 mrem

  17. Optimizing Radiation Doses for Computed Tomography Across Institutions: Dose Auditing and Best Practices.

    Science.gov (United States)

    Demb, Joshua; Chu, Philip; Nelson, Thomas; Hall, David; Seibert, Anthony; Lamba, Ramit; Boone, John; Krishnam, Mayil; Cagnon, Christopher; Bostani, Maryam; Gould, Robert; Miglioretti, Diana; Smith-Bindman, Rebecca

    2017-06-01

    Radiation doses for computed tomography (CT) vary substantially across institutions. To assess the impact of institutional-level audit and collaborative efforts to share best practices on CT radiation doses across 5 University of California (UC) medical centers. In this before/after interventional study, we prospectively collected radiation dose metrics on all diagnostic CT examinations performed between October 1, 2013, and December 31, 2014, at 5 medical centers. Using data from January to March (baseline), we created audit reports detailing the distribution of radiation dose metrics for chest, abdomen, and head CT scans. In April, we shared reports with the medical centers and invited radiology professionals from the centers to a 1.5-day in-person meeting to review reports and share best practices. We calculated changes in mean effective dose 12 weeks before and after the audits and meeting, excluding a 12-week implementation period when medical centers could make changes. We compared proportions of examinations exceeding previously published benchmarks at baseline and following the audit and meeting, and calculated changes in proportion of examinations exceeding benchmarks. Of 158 274 diagnostic CT scans performed in the study period, 29 594 CT scans were performed in the 3 months before and 32 839 CT scans were performed 12 to 24 weeks after the audit and meeting. Reductions in mean effective dose were considerable for chest and abdomen. Mean effective dose for chest CT decreased from 13.2 to 10.7 mSv (18.9% reduction; 95% CI, 18.0%-19.8%). Reductions at individual medical centers ranged from 3.8% to 23.5%. The mean effective dose for abdominal CT decreased from 20.0 to 15.0 mSv (25.0% reduction; 95% CI, 24.3%-25.8%). Reductions at individual medical centers ranged from 10.8% to 34.7%. The number of CT scans that had an effective dose measurement that exceeded benchmarks was reduced considerably by 48% and 54% for chest and abdomen, respectively. After

  18. Enhanced Light Narrow Transmission through Cascaded Metallic Structure with Periodic Aperture Arrays

    International Nuclear Information System (INIS)

    Yang Hong-Yan; Zhong Yan-Ru; Xiao Gong-Li; Zhang Zhen-Rong

    2012-01-01

    We present experimental and numerical studies on the enhanced light narrow transmission through cascaded Au/SiO x N y /Au aperture arrays by varying the refractive index and thickness of SiO x N y . It is found that the enhancement as well as narrowing of the optical transmission originates from the coupling role of surface plasmon polaritons. The results indicate that the transmission enhancement is highly dependent on the refractive index and thickness of SiO x N y . A higher transmission efficiency and narrower peak are obtained in Au/SiO 2.1 N 0.3 /Au structure with a small refractive index (1.6) and thin thickness (0.2 μm)

  19. Looking through an adolescent literacy lens at the narrow view of reading.

    Science.gov (United States)

    Ehren, Barbara J

    2009-04-01

    This commentary is a personal reaction to A. G. Kamhi's (2007) article on the "narrow view" of reading and his suggestion that this view be adopted as a way to address the reading problems of children and adolescents. In this article, I consider the narrow view of reading from an adolescent literacy perspective and discuss the practical implications of adopting this view in the schools. Discussion revolves around the complexities of reading comprehension, comprehension as a teachable set of complex processes, and the speech-language pathologist's role in reading comprehension. Although I acknowledge that the narrow view of reading may have merit, I opine that it may create more problems than it solves.

  20. Dose-rate and the reciprocity law: TL response of Ge-doped SiO{sub 2} optical fibers at therapeutic radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Abdul Rahman, A.T., E-mail: a.t.abdulrahman@surrey.ac.uk [Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, Guildford GU2 7XH, Surrey (United Kingdom); School of Physics and Material Studies, Faculty of Applied Sciences, Universiti Teknologi MARA Malaysia (UiTM), Campus of Negeri Sembilan, 72000 Kuala Pilah (Malaysia); Nisbet, A. [Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, Guildford GU2 7XH, Surrey (United Kingdom); Departments of Medical Physics, the Royal Surrey County Hospital (RSCH) NHS Trust, Edgerton Road, Guildford GU2 7XX, Surrey (United Kingdom); Bradley, D.A. [Centre for Nuclear and Radiation Physics, Department of Physics, University of Surrey, Guildford GU2 7XH, Surrey (United Kingdom)

    2011-10-01

    An investigation has been made on commercially available Ge-doped SiO{sub 2} optical fibers as a novel thermoluminescence system for radiotherapy dosimetry. This dosimeter has previously been shown by the group to provide sensitive dosimetry over a wide range of electron and photon dose, suitable for the needs of radiotherapy. In addition the optical fiber offers small physical size (125 {mu}m diameter) and hence high spatial resolution. The reciprocity between thermoluminescence (TL) yield of Ge-doped SiO{sub 2} optical fibers and dose has been investigated for fixed radiation dose for a range of photon and electron dose rates. For electron beams of nominal energies in the range of 9-20 MeV, we have investigated the TL response of these fibers for dose rates between 100 and 1000 cGy min{sup -1}. For photon beams of nominal energies in the range of 6-15 MV, we have used dose rates of 100-600 cGy min{sup -1}. Reproducibility and fading at fixed absorbed dose (3 Gy) and dose rate for the optical fibers were also investigated. At fixed dose rates, the TL optical fibers were found to produce a flat TL yield within 4% (1{sigma}) and 3% (1{sigma}) for electron and photon beams, respectively. The optical fibers demonstrated good reproducibility ({+-}1.5%), low residual signal for a readout temperature of 300 {sup o}C and negligible fading. A weak dependence on dose-rate has been observed in the range of 3.4-3.9% for electrons (with an associated uncertainty of 4%) and 2.4-2.9% for photons (with an associated uncertainty of <4%). For electron and photon energies we note a consistent trend towards lower response in the TL yield of between 3.4-3.9% and 2.4-2.7%, respectively, at the higher dose rates in comparison with the response at lower dose rates. In addition we note an appreciable systematic energy dependence for both electron and photon beams. It is important to take such factors into account for providing precise and accurate radiotherapy dosimetry. It is also

  1. Irradiation dose of cosmonauts

    International Nuclear Information System (INIS)

    Makra, Zs.

    1978-01-01

    The results obtained by determining the irradiation dose during the spaceflights of Apollo as well as the Sojouz-3 and Sojouz-9 spacecrafts have been compared in the form of tables. In case of Apollo astronauts the irradiation dose was determined by two methods and its sources were also pointed out, in tables. During Sojouz spacetravels the cosmonauts were exposed to a negligible dose. In spite of this fact the radiation danger is considerable. The small irradiation doses noticed so far are due to the fact that during the spaceflights there was no big proturberance. However, during the future long-range spacetravels a better radiation shielding than the one used up to now will be necessary. (P.J.)

  2. Dosimetric evaluation of the OneDoseTM MOSFET for measuring kilovoltage imaging dose from image-guided radiotherapy procedures.

    Science.gov (United States)

    Ding, George X; Coffey, Charles W

    2010-09-01

    The purpose of this study is to investigate the feasibility of using a single-use dosimeter, OneDose MOSFET designed for in vivo patient dosimetry, for measuring the radiation dose from kilovoltage (kV) x rays resulting from image-guided procedures. The OneDose MOSFET dosimeters were precalibrated by the manufacturer using Co-60 beams. Their energy response and characteristics for kV x rays were investigated by using an ionization chamber, in which the air-kerma calibration factors were obtained from an Accredited Dosimetry Calibration Laboratory (ADCL). The dosimetric properties have been tested for typical kV beams used in image-guided radiation therapy (IGRT). The direct dose reading from the OneDose system needs to be multiplied by a correction factor ranging from 0.30 to 0.35 for kilovoltage x rays ranging from 50 to 125 kVp, respectively. In addition to energy response, the OneDose dosimeter has up to a 20% reduced sensitivity for beams (70-125 kVp) incident from the back of the OneDose detector. The uncertainty in measuring dose resulting from a kilovoltage beam used in IGRT is approximately 20%; this uncertainty is mainly due to the sensitivity dependence of the incident beam direction relative to the OneDose detector. The ease of use may allow the dosimeter to be suitable for estimating the dose resulting from image-guided procedures.

  3. Photonic bandgap narrowing in conical hollow core Bragg fibers

    Energy Technology Data Exchange (ETDEWEB)

    Ozturk, Fahri Emre; Yildirim, Adem; Kanik, Mehmet [UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara (Turkey); Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara (Turkey); Bayindir, Mehmet, E-mail: bayindir@nano.org.tr [UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara (Turkey); Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara (Turkey); Department of Physics, Bilkent University, 06800 Ankara (Turkey)

    2014-08-18

    We report the photonic bandgap engineering of Bragg fibers by controlling the thickness profile of the fiber during the thermal drawing. Conical hollow core Bragg fibers were produced by thermal drawing under a rapidly alternating load, which was applied by introducing steep changes to the fiber drawing speed. In conventional cylindrical Bragg fibers, light is guided by omnidirectional reflections from interior dielectric mirrors with a single quarter wave stack period. In conical fibers, the diameter reduction introduced a gradient of the quarter wave stack period along the length of the fiber. Therefore, the light guided within the fiber encountered slightly smaller dielectric layer thicknesses at each reflection, resulting in a progressive blueshift of the reflectance spectrum. As the reflectance spectrum shifts, longer wavelengths of the initial bandgap cease to be omnidirectionally reflected and exit through the cladding, which narrows the photonic bandgap. A narrow transmission bandwidth is particularly desirable in hollow waveguide mid-infrared sensing schemes, where broadband light is coupled to the fiber and the analyte vapor is introduced into the hollow core to measure infrared absorption. We carried out sensing simulations using the absorption spectrum of isopropyl alcohol vapor to demonstrate the importance of narrow bandgap fibers in chemical sensing applications.

  4. High prevalence of narrow angles among Filipino-American patients.

    Science.gov (United States)

    Seider, Michael I; Sáles, Christopher S; Lee, Roland Y; Agadzi, Anthony K; Porco, Travis C; Weinreb, Robert N; Lin, Shan C

    2011-03-01

    To determine the prevalence of gonioscopically narrow anterior chamber angles in a Filipino-American clinic population. The records of 122 consecutive, new, self-declared Filipino-American patients examined in a comprehensive ophthalmology clinic in Vallejo, California were reviewed retrospectively. After exclusion, 222 eyes from 112 patients remained for analysis. Data were collected for anterior chamber angle grade as determined by gonioscopy (Shaffer system), age, sex, manifest refraction (spherical equivalent), intraocular pressure, and cup-to-disk ratio. Data from both eyes of patients were included and modeled using standard linear mixed-effects regression. As a comparison, data were also collected from a group of 30 consecutive White patients from the same clinic. After exclusion, 50 eyes from 25 White patients remained for comparison. At least 1 eye of 24% of Filipino-American patients had a narrow anterior chamber angle (Shaffer grade ≤ 2). Filipino-American angle grade significantly decreased with increasingly hyperopic refraction (P=0.007) and larger cup-to-disk ratio (P=0.038). Filipino-American women had significantly decreased angle grades compared with men (P=0.028), but angle grade did not vary by intraocular pressure or age (all, P≥ 0.059). Narrow anterior chamber angles are highly prevalent in Filipino-American patients in our clinic population.

  5. Electron correlations in narrow energy bands: modified polar model approach

    Directory of Open Access Journals (Sweden)

    L. Didukh

    2008-09-01

    Full Text Available The electron correlations in narrow energy bands are examined within the framework of the modified form of polar model. This model permits to analyze the effect of strong Coulomb correlation, inter-atomic exchange and correlated hopping of electrons and explain some peculiarities of the properties of narrow-band materials, namely the metal-insulator transition with an increase of temperature, nonlinear concentration dependence of Curie temperature and peculiarities of transport properties of electronic subsystem. Using a variant of generalized Hartree-Fock approximation, the single-electron Green's function and quasi-particle energy spectrum of the model are calculated. Metal-insulator transition with the change of temperature is investigated in a system with correlated hopping. Processes of ferromagnetic ordering stabilization in the system with various forms of electronic DOS are studied. The static conductivity and effective spin-dependent masses of current carriers are calculated as a function of electron concentration at various DOS forms. The correlated hopping is shown to cause the electron-hole asymmetry of transport and ferromagnetic properties of narrow band materials.

  6. Clinical and radiographic evaluation of early loaded narrow-diameter implants

    DEFF Research Database (Denmark)

    Maiorana, Carlo; King, Paul; Quaas, Sebastian

    2015-01-01

    OBJECTIVE: To evaluate the clinical reliability of narrow implants placed in a one-stage procedure and early loaded in the upper and lower incisor region. MATERIAL AND METHODS: This is a prospective, single-arm, multicenter study in which patients with missing natural dentition in upper lateral a...... be considered as a valid solution in the treatment of the localized narrow bony defects in the anterior area with reduced spaces between the natural teeth....... healing period. Clinical and radiographic checks were performed at implant placement, loading, and at the 6, 12, 24, and 36 months follow-up visits. RESULTS: A total of 69 subjects with 97 implants have been included in this study. From surgery to 36 months follow-up, 5.6% of the implants showed bone loss...... loss between loading and the 1-year follow-up visit (Galindo-Moreno et al. 2012). This finding, associated with a stable probing pocket depth and a stable crown-gingiva distance, using a one-stage surgical procedure helps to maintain the integrity of the peri-implant soft tissues. Narrow implants can...

  7. Nonlinear narrow Doppler-free resonances for optical transitions and annihilation radiation of a positronium atom

    International Nuclear Information System (INIS)

    Letokhov, V.S.; Minogin, V.G.

    1976-01-01

    The possibilities of obtaining narrow resonances without the Doppler broadening for transition between the fine structure levels of the ground and first excited states of a positronium atom are considered. An analysis is carried out of the conditions required for observation of the narrow resonances of saturation of single quantum absorption in the 1S-2P transitions and observation of narrow two-photon absorption resonances in the 1S-2S transitions. It is shown that narrow 2γ annihilation radiation lines of a positronium atom may be obtained with a width much smaller than the Doppler one

  8. Warfarin: do we need genotype-based dose prediction?

    Directory of Open Access Journals (Sweden)

    Yenny Yenny

    2016-02-01

    Full Text Available For the treatment and prevention of thrombo-embolic disease, the most frequently used anticoagulant drug worldwide is warfarin, an oral coumarin derivative, with more than 30 million prescriptions written for this drug in the United States in 2004.(1 The drug has a narrow therapeutic index and its metabolism varies by as much as a factor of 10 among individual patients, making warfarin therapy difficult to manage. Hemorrhagic complication rates of warfarin are estimated to be 5-7.9% for major (life threatening hemorrhage and 14-36% for minor hemorrhage (e.g. nosebleeds, microscopic hematuria.(2 This condition makes it difficult to establish the appropriate dose of warfarin.

  9. Influence of dose and dose rate on the physical properties of commercial papers commonly used in libraries and archives

    Science.gov (United States)

    Area, María C.; Calvo, Ana M.; Felissia, Fernando E.; Docters, Andrea; Miranda, María V.

    2014-03-01

    The aim of this study was to evaluate the effects of dose and dose rate of gamma irradiation on the physical properties of commercial papers commonly used in libraries and archives to optimize the irradiation conditions. Three different brands of paper of different fiber compositions were treated, using a 32 factorial design with four replicates of the center point, with doses ranging from 2 to 11 kGy and dose rates between 1 and 11 kGy/h. Chemical, mechanical and optical properties were determined on the samples. With some differences between the different kinds of papers, tensile strength, elongation, TEA, and air resistance were in general, unaffected by the treatment. The minimum loss of tear resistance and brightness were obtained with doses in the range 4-6 kGy at any dose rate for all three kinds of paper. These conditions are ideal to remove insects and sufficient to eliminate fungus.

  10. Narrow gap electronegative capacitive discharges

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, E.; Lieberman, M. A.; Lichtenberg, A. J. [Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720 (United States)

    2013-10-15

    Narrow gap electronegative (EN) capacitive discharges are widely used in industry and have unique features not found in conventional discharges. In this paper, plasma parameters are determined over a range of decreasing gap length L from values for which an electropositive (EP) edge exists (2-region case) to smaller L-values for which the EN region connects directly to the sheath (1-region case). Parametric studies are performed at applied voltage V{sub rf}=500 V for pressures of 10, 25, 50, and 100 mTorr, and additionally at 50 mTorr for 1000 and 2000 V. Numerical results are given for a parallel plate oxygen discharge using a planar 1D3v (1 spatial dimension, 3 velocity components) particle-in-cell (PIC) code. New interesting phenomena are found for the case in which an EP edge does not exist. This 1-region case has not previously been investigated in detail, either numerically or analytically. In particular, attachment in the sheaths is important, and the central electron density n{sub e0} is depressed below the density n{sub esh} at the sheath edge. The sheath oscillations also extend into the EN core, creating an edge region lying within the sheath and not characterized by the standard diffusion in an EN plasma. An analytical model is developed using minimal inputs from the PIC results, and compared to the PIC results for a base case at V{sub rf}=500 V and 50 mTorr, showing good agreement. Selected comparisons are made at the other voltages and pressures. A self-consistent model is also developed and compared to the PIC results, giving reasonable agreement.

  11. Preparation of the spacer for narrow electrode gap configuration in ionization-based gas sensor

    International Nuclear Information System (INIS)

    Saheed, Mohamed Shuaib Mohamed; Mohamed, Norani Muti; Burhanudin, Zainal Arif

    2012-01-01

    Carbon nanotubes (CNTs) have started to be developed as the sensing element for ionization-based gas sensors due to the demand for improved sensitivity, selectivity, stability and other sensing properties beyond what can be offered by the conventional ones. Although these limitations have been overcome, the problems still remain with the conventional ionization-based gas sensors in that they are bulky and operating with large breakdown voltage and high temperature. Recent studies have shown that the breakdown voltage can be reduced by using nanostructured electrodes and narrow electrode gap. Nanostructured electrode in the form of aligned CNTs array with evenly distributed nanotips can enhance the linear electric field significantly. The later is attributed to the shorter conductivity path through narrow electrode gap. The paper presents the study on the design consideration in order to realize ionization based gas sensor using aligned carbon nanotubes array in an optimum sensor configuration with narrow electrode gap. Several deposition techniques were studied to deposit the spacer, the key component that can control the electrode gap. Plasma spray deposition, electron beam deposition and dry oxidation method were employed to obtain minimum film thickness around 32 μm. For plasma spray method, sand blasting process is required in order to produce rough surface for strong bonding of the deposited film onto the surface. Film thickness, typically about 39 μm can be obtained. For the electron beam deposition and dry oxidation, the film thickness is in the range of nanometers and thus unsuitable to produce the spacer. The deposited multilayer film consisting of copper, alumina and ferum on which CNTs array will be grown was found to be removed during the etching process. This is attributed to the high etching rate on the thin film which can be prevented by reducing the rate and having a thicker conductive copper film.

  12. Preparation of the spacer for narrow electrode gap configuration in ionization-based gas sensor

    Energy Technology Data Exchange (ETDEWEB)

    Saheed, Mohamed Shuaib Mohamed; Mohamed, Norani Muti; Burhanudin, Zainal Arif [Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, Seri Iskandar, Tronoh, Perak. (Malaysia); Fundamental and Applied Science, Universiti Teknologi PETRONAS, Seri Iskandar, Tronoh, Perak. (Malaysia); Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, Seri Iskandar, Tronoh, Perak. (Malaysia)

    2012-09-26

    Carbon nanotubes (CNTs) have started to be developed as the sensing element for ionization-based gas sensors due to the demand for improved sensitivity, selectivity, stability and other sensing properties beyond what can be offered by the conventional ones. Although these limitations have been overcome, the problems still remain with the conventional ionization-based gas sensors in that they are bulky and operating with large breakdown voltage and high temperature. Recent studies have shown that the breakdown voltage can be reduced by using nanostructured electrodes and narrow electrode gap. Nanostructured electrode in the form of aligned CNTs array with evenly distributed nanotips can enhance the linear electric field significantly. The later is attributed to the shorter conductivity path through narrow electrode gap. The paper presents the study on the design consideration in order to realize ionization based gas sensor using aligned carbon nanotubes array in an optimum sensor configuration with narrow electrode gap. Several deposition techniques were studied to deposit the spacer, the key component that can control the electrode gap. Plasma spray deposition, electron beam deposition and dry oxidation method were employed to obtain minimum film thickness around 32 {mu}m. For plasma spray method, sand blasting process is required in order to produce rough surface for strong bonding of the deposited film onto the surface. Film thickness, typically about 39 {mu}m can be obtained. For the electron beam deposition and dry oxidation, the film thickness is in the range of nanometers and thus unsuitable to produce the spacer. The deposited multilayer film consisting of copper, alumina and ferum on which CNTs array will be grown was found to be removed during the etching process. This is attributed to the high etching rate on the thin film which can be prevented by reducing the rate and having a thicker conductive copper film.

  13. Narrow-band tunable terahertz emission from ferrimagnetic Mn{sub 3-x}Ga thin films

    Energy Technology Data Exchange (ETDEWEB)

    Awari, N. [Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstr. 400, 01328 Dresden (Germany); University of Groningen, 9747 AG Groningen (Netherlands); Kovalev, S., E-mail: s.kovalev@hzdr.de, E-mail: c.fowley@hzdr.de, E-mail: rodek@tcd.ie; Fowley, C., E-mail: s.kovalev@hzdr.de, E-mail: c.fowley@hzdr.de, E-mail: rodek@tcd.ie; Green, B.; Yildirim, O.; Lindner, J.; Fassbender, J.; Deac, A. M.; Gensch, M. [Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstr. 400, 01328 Dresden (Germany); Rode, K., E-mail: s.kovalev@hzdr.de, E-mail: c.fowley@hzdr.de, E-mail: rodek@tcd.ie; Lau, Y.-C.; Betto, D.; Thiyagarajah, N.; Coey, J. M. D. [CRANN, AMBER and School of Physics, Trinity College Dublin, Dublin 2 (Ireland); Gallardo, R. A. [Departamento de Física, Universidad Técnica Federico Santa María, Avenida España 1680, 2390123 Valparíso (Chile)

    2016-07-18

    Narrow-band terahertz emission from coherently excited spin precession in metallic ferrimagnetic Mn{sub 3-x}Ga Heusler alloy nanofilms has been observed. The efficiency of the emission, per nanometer film thickness, is comparable or higher than that of classical laser-driven terahertz sources based on optical rectification. The center frequency of the emission from the films can be tuned precisely via the film composition in the range of 0.20–0.35 THz, making this type of metallic film a candidate for efficient on-chip terahertz emitters. Terahertz emission spectroscopy is furthermore shown to be a sensitive probe of magnetic properties of ultra-thin films.

  14. Association of lens vault with narrow angles among different ethnic groups.

    Science.gov (United States)

    Lee, Roland Y; Huang, Guofu; Cui, Qi N; He, Mingguang; Porco, Travis C; Lin, Shan C

    2012-06-01

    To compare lens vault between open-angle and narrow-angle eyes in African-, Caucasian-, Hispanic-, Chinese- and Filipino-Americans. In this prospective study, 436 patients with open angle and narrow angle based on the Shaffer gonioscopic grading classification underwent anterior-segment optical coherence tomography. The Zhongshan Angle Assessment Program was used to calculate lens vault. The narrow-angle group included 32 Chinese-Americans, 22 Filipino-Americans, 26 African-Americans, 24 Hispanic-Americans and 73 Caucasian-Americans. The open-angle group included 56 Chinese-Americans, 29 Filipino-Americans, 45 African-Americans, 27 Hispanic-Americans and 102 Caucasian-Americans. Linear mixed effect regression models, accounting for the use of both eyes and adjusting for age, sex, pupil diameter and spherical equivalent, were used to test for the ethnicity and angle coefficients. Tukey's multiple comparison test was used for pairwise comparisons among the open-angle racial groups. Significant difference in lens vault was found among the open-angle racial groups (P = 0.022). For the open-angle patients, mean values for the lens vault measurements were 265 ± 288 µm for Chinese-Americans, 431 ± 248 µm for Caucasian-Americans, 302 ± 213 µm for Filipino-Americans, 304 ± 263 µm for Hispanic-Americans and 200 ± 237 µm for African-Americans. Using Tukey's multiple comparison for pairwise comparisons among the open-angle racial groups, a significant difference was found between African-American and Caucasian-Americans groups (P values for the rest of the pairwise comparisons were not statistically significant. No significant difference was found among the narrow-angle racial groups (P = 0.14). Comparison between the open angle and narrow angle within each racial group revealed significant difference for all racial groups (P < 0.05). Among all the ethnicities included in this study, narrow-angle eyes have greater lens vault compared to open

  15. The irradiation effects and processing dose for pet foods decontamination

    International Nuclear Information System (INIS)

    Zhu Jiating; Feng Min; Liu Chunquan; Zhao Yongfu; Jin Yudong; Ji Ping; Ha Yiming; Gao Meixu; Li Shurong; Wang Feng; Zhou Hongjie

    2009-01-01

    The applied dose range of irradiation processing of 4 kinds of pet foods had been studied. More than 92% microorganisms was inactive at the irradiation dose of 4 kGy, while more than 99% was inactive at 6 kGy. The microorganism load of irradiated pet food by 8 kGy met the requirement of national standards. The 10 kGy irradiation could sterilize the treated pet food. Salmonella had not been checked in irradiated or unirradiated samples. When irradiation dose ranged 4-10 kGy, there was no significant difference on contents of moisture, fat, protein, coarse fiber, carbohydrates, minerals (not including Calcium) or amino acids between irradiated and un-irradiated pet food. There was also no significant change on sensory quality of irradiated samples within this dose range. It is concluded that the recommended irradiation processing dose range for pet foods is 4-10 kGy. (authors)

  16. Narrow coherent effects in πNN-dynamics

    International Nuclear Information System (INIS)

    Kudryavtsev, A.E.; Obrant, G.Z.

    1990-01-01

    Coherent effect production is considered in πNN-dynamics with resonant pion-nucleon interaction via Brueckner theory and Faddev equations. It is shown that the narrow energy and final momentum dependence can arise in the inelastic S-wave πd-scattering. The energy dependence peculiarities can have a width an order magnitude less than πN-resonance one

  17. Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT

    International Nuclear Information System (INIS)

    Rampado, Osvaldo; Giglioli, Francesca Romana; Rossetti, Veronica; Ropolo, Roberto; Fiandra, Christian; Ragona, Riccardo

    2016-01-01

    Purpose: The aim of this study was to evaluate various approaches for assessing patient organ doses resulting from radiotherapy cone-beam CT (CBCT), by the use of thermoluminescent dosimeter (TLD) measurements in anthropomorphic phantoms, a Monte Carlo based dose calculation software, and different dose indicators as presently defined. Methods: Dose evaluations were performed on a CBCT Elekta XVI (Elekta, Crawley, UK) for different protocols and anatomical regions. The first part of the study focuses on using PCXMC software (PCXMC 2.0, STUK, Helsinki, Finland) for calculating organ doses, adapting the input parameters to simulate the exposure geometry, and beam dose distribution in an appropriate way. The calculated doses were compared to readouts of TLDs placed in an anthropomorphic Rando phantom. After this validation, the software was used for analyzing organ dose variability associated with patients’ differences in size and gender. At the same time, various dose indicators were evaluated: kerma area product (KAP), cumulative air-kerma at the isocenter (K_a_i_r), cone-beam dose index, and central cumulative dose. The latter was evaluated in a single phantom and in a stack of three adjacent computed tomography dose index phantoms. Based on the different dose indicators, a set of coefficients was calculated to estimate organ doses for a range of patient morphologies, using their equivalent diameters. Results: Maximum organ doses were about 1 mGy for head and neck and 25 mGy for chest and pelvis protocols. The differences between PCXMC and TLDs doses were generally below 10% for organs within the field of view and approximately 15% for organs at the boundaries of the radiation beam. When considering patient size and gender variability, differences in organ doses up to 40% were observed especially in the pelvic region; for the organs in the thorax, the maximum differences ranged between 20% and 30%. Phantom dose indexes provided better correlation with organ doses

  18. Advantages and successful use of TIG narrow-gap welding

    International Nuclear Information System (INIS)

    Loehberg, R.; Pellkofer, D.; Schmidt, J.

    1986-01-01

    Narrow-gap welding, an advancement of the mechanized TIG impulse welding process with conventional seam geometry (V-shaped and/or U-shaped welds), not only assures great economic efficiency on account of the low weld volume but also offers considerable benefits in terms of quality. Thanks to the low number of beads, the following advantages are gained: less axial and radial shrinkage which reduces the strain in the root area, total heat input and, thus, the dwell time in the critical temperature range from 500 to 800 0 C leading to a chromium depletion at the grain boundaries during the welding process is minimized which markedly reduces the sensitivity of non-stabilized steels to intercrystalline stress corrosion cracking, and a relatively favourable residual welding stress profile in the heat affected zone. The process was used successfully in the past for welds of ferritic and austenitic steel pipes in the construction of nuclear power plants and in the remote-controlled welding during the replacement of piping in plants already in operation. (orig.) [de

  19. Dose measurements in mammography

    International Nuclear Information System (INIS)

    Kainberger, F.; Kallinger, W.

    1977-01-01

    Dose measurements at the mamma during mammography were carried out in the form of direct measurement with thermoluminescent dosimetry. Measurement was done for the in- and outcoming doses at the mamma, the dose exposure of the sternal region and the scattered rays above the symphysis, the latter as parameter for the genetic radiation exposure. As expected, the dose of the smooth radiation used for mammography showed a strong decrease at the outcome point in comparison with the income point. Surprisingly high was the scattered radiation in the sternal region. A corresponding protection by lead plates could be taken into consideration. Extremely low is the scattered radiation above the symphysis. Even measurements with the very sensitive calcium fluoride dosimeters did not reveal any practically important dose in the symphysis region. Most measurement values remained below the determinable dose of 0.3mR. Some maximal values varied in the range of 3-1 mR. (orig.) [de

  20. Damage growth in Si during self-ion irradiation: A study of ion effects over an extended energy range

    International Nuclear Information System (INIS)

    Holland, O.W.; El-Ghor, M.K.; White, C.W.

    1989-01-01

    Damage nucleation/growth in single-crystal Si during ion irradiation is discussed. For MeV ions, the rate of growth as well as the damage morphology are shown to vary widely along the track of the ion. This is attributed to a change in the dominant, defect-related reactions as the ion penetrates the crystal. The nature of these reactions were elucidated by studying the interaction of MeV ions with different types of defects. The defects were introduced into the Si crystal prior to high-energy irradiation by self-ion implantation at a medium energy (100 keV). Varied damage morphologies were produced by implanting different ion fluences. Electron microscopy and ion-channeling measurements, in conjunction with annealing studies, were used to characterize the damage. Subtle changes in the predamage morphology are shown to result in markedly different responses to the high-energy irradiation, ranging from complete annealing of the damage to rapid growth. These divergent responses occur over a narrow range of dose (2--3 times 10 14 cm -2 ) of the medium-energy ions; this range also marks a transition in the growth behavior of the damage during the predamage implantation. A model is proposed which accounts for these observations and provides insight into ion-induced growth of amorphous layers in Si and the role of the amorphous/crystalline interface in this process. 15 refs, 9 figs

  1. Effect of γ-dose rate and total dose interrelation on the polymeric hydrogel: A novel injectable male contraceptive

    International Nuclear Information System (INIS)

    Jha, Pradeep K.; Jha, Rakhi; Gupta, B.L.; Guha, Sujoy K.

    2010-01-01

    Functional necessity to use a particular range of dose rate and total dose of γ-initiated polymerization to manufacture a novel polymeric hydrogel RISUG (reversible inhibition of sperm under guidance) made of styrene maleic anhydride (SMA) dissolved in dimethyl sulphoxide (DMSO), for its broad biomedical application explores new dimension of research. The present work involves 16 irradiated samples. They were tested by fourier transform infrared spectroscopy, matrix assisted laser desorption/ionization-TOF, field emission scanning electron microscopy, high resolution transmission electron microscopy, etc. to see the interrelation effect of gamma dose rates (8.25, 17.29, 20.01 and 25.00 Gy/min) and four sets of doses (1.8, 2.0, 2.2 and 2.4 kGy) on the molecular weight, molecular weight distribution and porosity analysis of the biopolymeric drug RISUG. The results of randomized experiment indicated that a range of 18-24 Gy/min γ-dose rate and 2.0-2.4 kGy γ-total doses is suitable for the desirable in vivo performance of the contraceptive copolymer.

  2. A Fixed-Frequency Bidirectional Resonant DC-DC Converter Suitable for Wide Voltage Gain Range

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Blaabjerg, Frede

    2017-01-01

    This paper proposes a new bidirectional resonant dc-dc converter suitable for wide voltage gain range applications (e.g., energy storage systems). The proposed converter overcomes the narrow voltage gain range of conventional resonant DC-DC converters, and meanwhile achieves high efficiency...... and characteristics of the proposed converter are analyzed. Finally, a 1-kW converter prototype is built and the experimental results verify the theoretical analyses....

  3. Radiation dose reduction in parasinus CT by spectral shaping

    Energy Technology Data Exchange (ETDEWEB)

    May, Matthias S.; Brand, Michael; Lell, Michael M.; Uder, Michael; Wuest, Wolfgang [University Hospital Erlangen, Department of Radiology, Erlangen (Germany); Sedlmair, Martin; Allmendinger, Thomas [Siemens Healthcare GmbH, Forchheim (Germany)

    2017-02-15

    Spectral shaping aims to narrow the X-ray spectrum of clinical CT. The aim of this study was to determine the image quality and the extent of radiation dose reduction that can be achieved by tin prefiltration for parasinus CT. All scans were performed with a third generation dual-source CT scanner. A study protocol was designed using 100 kV tube voltage with tin prefiltration (200 mAs) that provides image noise levels comparable to a low-dose reference protocol using 100 kV without spectral shaping (25 mAs). One hundred consecutive patients were prospectively enrolled and randomly assigned to the study or control group. All patients signed written informed consent. The study protocol was approved by the local Institutional Review Board and applies to the HIPAA. Subjective and objective image quality (attenuation values, image noise, and contrast-to-noise ratio (CNR)) were assessed. Radiation exposure was assessed as volumetric CT dose index, and effective dose was estimated. Mann-Whitney U test was performed for radiation exposure and for image noise comparison. All scans were of diagnostic image quality. Image noise in air, in the retrobulbar fat, and in the eye globe was comparable between both groups (all p > 0.05). CNR{sub eye} {sub globe/air} did not differ significantly between both groups (p = 0.7). Radiation exposure (1.7 vs. 2.1 mGy, p < 0.01) and effective dose (0.055 vs. 0.066 mSv, p < 0.01) were significantly reduced in the study group. Radiation dose can be further reduced by 17% for low-dose parasinus CT by tin prefiltration maintaining diagnostic image quality. (orig.)

  4. Radiation dose reduction in parasinus CT by spectral shaping

    International Nuclear Information System (INIS)

    May, Matthias S.; Brand, Michael; Lell, Michael M.; Uder, Michael; Wuest, Wolfgang; Sedlmair, Martin; Allmendinger, Thomas

    2017-01-01

    Spectral shaping aims to narrow the X-ray spectrum of clinical CT. The aim of this study was to determine the image quality and the extent of radiation dose reduction that can be achieved by tin prefiltration for parasinus CT. All scans were performed with a third generation dual-source CT scanner. A study protocol was designed using 100 kV tube voltage with tin prefiltration (200 mAs) that provides image noise levels comparable to a low-dose reference protocol using 100 kV without spectral shaping (25 mAs). One hundred consecutive patients were prospectively enrolled and randomly assigned to the study or control group. All patients signed written informed consent. The study protocol was approved by the local Institutional Review Board and applies to the HIPAA. Subjective and objective image quality (attenuation values, image noise, and contrast-to-noise ratio (CNR)) were assessed. Radiation exposure was assessed as volumetric CT dose index, and effective dose was estimated. Mann-Whitney U test was performed for radiation exposure and for image noise comparison. All scans were of diagnostic image quality. Image noise in air, in the retrobulbar fat, and in the eye globe was comparable between both groups (all p > 0.05). CNR_e_y_e _g_l_o_b_e_/_a_i_r did not differ significantly between both groups (p = 0.7). Radiation exposure (1.7 vs. 2.1 mGy, p < 0.01) and effective dose (0.055 vs. 0.066 mSv, p < 0.01) were significantly reduced in the study group. Radiation dose can be further reduced by 17% for low-dose parasinus CT by tin prefiltration maintaining diagnostic image quality. (orig.)

  5. LETTER TO THE EDITOR: Green emission and bandgap narrowing due to two-photon excitation in thin film CdS formed by spray pyrolysis

    Science.gov (United States)

    Ullrich, B.; Schroeder, R.

    2001-08-01

    Thin (10 µm) film CdS on Pyrex® formed by spray pyrolysis is excited below the gap at 804 nm with 200 fs laser pulses at room temperature. Excitation intensities up to 250 GW cm-2 evoke green bandgap emission due to two-photon transitions. This two-photon photoluminescence does not show a red emission contribution in contrast to the single-photon excited emission, which is dominated by broad emission in the red spectral range. It is demonstrated that two-photon excitation causes photo-induced bandgap narrowing due to Debye screening. At 250 GW cm-2 bandgap narrowing of 47 meV is observed, which corresponds to an excited electron density of 1.6×1018 cm-3.

  6. Production of highly polarized 3He using spectrally narrowed diode laser array bars

    International Nuclear Information System (INIS)

    Chann, B.; Babcock, E.; Anderson, L.W.; Walker, T.G.; Chen, W.C.; Smith, T.B.; Thompson, A.K.; Gentile, T.R.

    2003-01-01

    We have produced 70%-75% 3 He polarization by spin-exchange optical pumping in cells ≅100 cm 3 in volume. The polarization achieved is consistent with known spin-exchange and spin-relaxation rates, but only when the recently discovered temperature dependence of 3 He relaxation is included. Absolute 3 He polarization measurements were performed using two different methods in two different laboratories. The results were obtained with either a spectrally narrowed laser or one type of broadband laser. Based on tests of several larger cells at pressures near 1 bar, we find that the power required to reach the same polarization is typically three times lower for the spectrally narrowed laser. This last result indicates that spectrally narrowed lasers will be important for obtaining the highest polarization in large volume neutron spin filters. Polarization in excess of 55% as obtained in cells up to 640 cm 3 in volume and 70% polarization is anticipated with available increases in spectrally narrowed laser power

  7. A CONCEPTUAL FRAMEWORK FOR MANAGING RADIATION DOSE TO PATIENTS IN DIAGNOSTIC RADIOLOGY USING REFERENCE DOSE LEVELS.

    Science.gov (United States)

    Almén, Anja; Båth, Magnus

    2016-06-01

    The overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined. The outset of the optimisation process is four stages: providing equipment, establishing methodology, performing examinations and ensuring quality. The optimisation process comprises a series of activities and actions at these stages. The current system of diagnostic reference levels is an activity in the last stage, ensuring quality. The system becomes a reactive activity only to a certain extent engaging the core activity in the radiology department, performing examinations. Three reference dose levels-possible, expected and established-were assigned to the three stages in the optimisation process, excluding ensuring quality. A reasonably achievable dose range is also derived, indicating an acceptable deviation from the established dose level. A reasonable radiation dose for a single patient is within this range. The suggested framework for managing radiation dose should be regarded as one part of the optimisation process. The optimisation process constitutes a variety of complementary activities, where managing radiation dose is only one part. This emphasises the need to take a holistic approach integrating the optimisation process in different clinical activities. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Radio frequency (RF) time-of-flight ranging for wireless sensor networks

    International Nuclear Information System (INIS)

    Thorbjornsen, B; White, N M; Brown, A D; Reeve, J S

    2010-01-01

    Position information of nodes within wireless sensor networks (WSNs) is often a requirement in order to make use of the data recorded by the sensors themselves. On deployment the nodes normally have no prior knowledge of their position and thus a locationing mechanism is required to determine their positions. In this paper, we describe a method to determine the point-to-point range between sensor nodes as part of the locationing process. A two-way time-of-flight (TOF) ranging scheme is presented using narrow-band RF. The frequency difference between the transceivers involved with the point-to-point measurement is used to obtain a sub-clock TOF phase offset measurement in order to achieve high resolution TOF measurements. The ranging algorithm has been developed and prototyped on a TI CC2430 development kit with no additional hardware being required. Performance results have been obtained for the line-of-sight (LOS), non-line-of-sight (NLOS) and indoor conditions. Accuracy is typically better than 7.0 m RMS for the LOS condition over 250.0 m and 15.8 m RMS for the NLOS condition over 120.0 m using a 100 sample average. Indoor accuracy is measured to 1.7 m RMS using a 1000 sample average over 8.0 m. Ranging error is linear and does not increase with the increased transmitter–receiver distance. Our TOA ranging scheme demonstrates a novel system where resolution and accuracy are time dependent in comparison with alternative frequency-dependent methods using narrow-band RF

  9. Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Expósito, M., E-mail: mariateresa.romero@uab.cat; Domingo, C.; Ortega-Gelabert, O.; Gallego, S. [Grup de Recerca en Radiacions Ionizants (GRRI), Departament de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Sánchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009 (Spain); Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41009 (Spain)

    2016-01-15

    Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose

  10. Free-Molecular Gas Flow in Narrow (Nanoscale) Channel

    Czech Academy of Sciences Publication Activity Database

    Levdansky, V.V.; Roldugin, V.I.; Žďanov, V.M.; Ždímal, Vladimír

    2014-01-01

    Roč. 87, č. 4 (2014), s. 802-814 ISSN 1062-0125 Grant - others:BRFFI(BY) T12P-018; RFBR(RU) 12-08-90009 Institutional support: RVO:67985858 Keywords : narrow channels * free-molecular gas flow * surface diffusion Subject RIV: CF - Physical ; Theoretical Chemistry

  11. Fiber optical dose rate measurement based on the luminescence of beryllium oxide

    Directory of Open Access Journals (Sweden)

    Teichmann Tobias

    2018-01-01

    Full Text Available This work presents a fiber optical dose rate measurement system based on the radioluminescence and optically stimulated luminescence of beryllium oxide. The system consists of a small, radiation sensitive probe which is coupled to a light detection unit with a long and flexible light guide. Exposing the beryllium oxide probe to ionizing radiation results in the emission of light with an intensity which is proportional to the dose rate. Additionally, optically stimulated luminescence can be used to obtain dose and dose rate information during irradiation or retrospectively. The system is capable of real time dose rate measurements in fields of high dose rates and dose rate gradients and in complex, narrow geometries. This enables the application for radiation protection measurements as well as for quality control in radiotherapy. One inherent drawback of fiber optical dosimetry systems is the generation of Cherenkov radiation and luminescence in the light guide itself when it is exposed to ionizing radiation. This so called “stem” effect leads to an additional signal which introduces a deviation in the dose rate measurement and reduces the spatial resolution of the system, hence it has to be removed. The current system uses temporal discrimination of the effect for radioluminescence measurements in pulsed radiation fields and modulated optically stimulated luminescence for continuous irradiation conditions. This work gives an overview of the major results and discusses new-found obstacles of the applied methods of stem discrimination.

  12. Left mainstem bronchial narrowing: a vascular compression syndrome? Evaluation by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hungate, R.G.; Newman, B.; Meza, M.P.

    1998-01-01

    Background and objective. Vascular compression of the left mainstem bronchus (LMSB) between the descending aorta (DA) and pulmonary artery (PA) has been suggested as a cause for LMSB narrowing in children. These anatomic relationships have not been compared with those in children with a normal LMSB. Materials and methods. We undertook a retrospective review of the medical and radiologic records of 10 symptomatic young children (1-19 months, 5 boys, 5 girls) with MR demonstration of LMSB narrowing and compared them to 40 young children without great vessel or bronchial abnormality on MR (1 week-19 months, 28 boys, 12 girls). Chest MR evaluation included assessment of airway and great vessel anatomy with specific attention to the course of the LMSB and its relationship to the adjacent DA and PA. The position of the DA in relation to the spine was carefully evaluated. Results. Five children had focal and five had diffuse LMSB narrowing. DA position at the level of the crossing LMSB: in 40 % of symptomatic children the DA was located in front of the adjacent vertebral body; in 40 %, 1 / 2 - 3 / 4 and in 20 % 1 / 4 - 1 / 2 of the circumference of the DA was located anterior to the spine. In the control group, the DA was prespinal in 10 %, with a trend toward a more paraspinal location of the DA. The trend toward a difference in position of the DA between symptomatic and control patients was statistically significant (P < 0.05). DA position was not related to age (up to 19 months). At the level where the LMSB crossed the DA, a segment of the PA was located anterior to the LMSB, more often the right PA (RPA) or pulmonary bifurcation in symptomatic children and the left PA (LPA) in controls. No correlation was apparent between length of LMSB narrowing and DA or PA position. Chest radiographic abnormalities, when present, were subtle. Excellent MR/bronchoscopic correlation of LMSB narrowing was found in nine of the ten symptomatic children. One child underwent posterior

  13. Dose and dose rate extrapolation factors for malignant and non-malignant health endpoints after exposure to gamma and neutron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Tran, Van; Little, Mark P. [National Cancer Institute, Radiation Epidemiology Branch, Rockville, MD (United States)

    2017-11-15

    Murine experiments were conducted at the JANUS reactor in Argonne National Laboratory from 1970 to 1992 to study the effect of acute and protracted radiation dose from gamma rays and fission neutron whole body exposure. The present study reports the reanalysis of the JANUS data on 36,718 mice, of which 16,973 mice were irradiated with neutrons, 13,638 were irradiated with gamma rays, and 6107 were controls. Mice were mostly Mus musculus, but one experiment used Peromyscus leucopus. For both types of radiation exposure, a Cox proportional hazards model was used, using age as timescale, and stratifying on sex and experiment. The optimal model was one with linear and quadratic terms in cumulative lagged dose, with adjustments to both linear and quadratic dose terms for low-dose rate irradiation (<5 mGy/h) and with adjustments to the dose for age at exposure and sex. After gamma ray exposure there is significant non-linearity (generally with upward curvature) for all tumours, lymphoreticular, respiratory, connective tissue and gastrointestinal tumours, also for all non-tumour, other non-tumour, non-malignant pulmonary and non-malignant renal diseases (p < 0.001). Associated with this the low-dose extrapolation factor, measuring the overestimation in low-dose risk resulting from linear extrapolation is significantly elevated for lymphoreticular tumours 1.16 (95% CI 1.06, 1.31), elevated also for a number of non-malignant endpoints, specifically all non-tumour diseases, 1.63 (95% CI 1.43, 2.00), non-malignant pulmonary disease, 1.70 (95% CI 1.17, 2.76) and other non-tumour diseases, 1.47 (95% CI 1.29, 1.82). However, for a rather larger group of malignant endpoints the low-dose extrapolation factor is significantly less than 1 (implying downward curvature), with central estimates generally ranging from 0.2 to 0.8, in particular for tumours of the respiratory system, vasculature, ovary, kidney/urinary bladder and testis. For neutron exposure most endpoints, malignant and

  14. Patient doses in interventional cardiology procedures

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.

    2008-01-01

    In most countries of European Union legislation requires the determination of the total skin dose to patient resulting from interventional procedures to assess the risk of deterministic effect. To this end, various dose indicators like dose area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used in clinical practice. The study aims at relating those dose indicators with doses ascribe to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). For the study the local MSD and related to their areas are investigated and compared for coronary angiography CA and intervention (PCI). Two methods implying radiographic films Kodak EDR2 and matrixes of thermoluminescent dosimeters (TLDs) are applied for direct measurements of dose distribution for selected procedures. Both methods are compared. Additionally, for patient dosimetry the following data: MSD, CD, EFD, fluoroscopy time (FT), number of acquired images, total DAP, fluoro-DAP and record-DAP were collected for randomly selected procedure. The statistical quantities like: median, 3 rd quartile, mean and standard deviation for all dosimetric parameters are determined. Preliminary study showed that the values of data collected for coronary procedures are in the ranges 0,7 - 27,3 min for fluoroscopy time, 50 - 350 Gy cm 2 for total DAP, 300 - 2000 mGy for CD, 140 - 2000 mGy for EFD and 100 - 1500 mGy for local maximal skin dose. For interventions the ranges are, accordingly 3,0 - 43,6 min , 25 - 450 Gy cm 2 , 270 - 6600 mGy, 80 - 2600 mGy and 80 - 1500 mGy. As a result of the study the correlations between dose indicators and local MSD are analyzed. The concentration of dose on irradiated films are going to be investigated in some detail as well. (author)

  15. Extremity doses to interventional radiologists

    International Nuclear Information System (INIS)

    Wihtby, M.; Martin, C. J.

    2002-01-01

    Radiologists performing interventional procedures are often required to stand close to the patient's side when carrying out manipulations under fluoroscopic control. This can result in their extremities receiving a high radiation dose, due to scattered radiation. These doses are sometimes high enough to warrant that the radiologist in question be designated a classified radiation worker. Classification in the UK is a result of any worker receiving or likely to receive in the course of their duties in excess of 3/10ths of any annual dose limit (500mSv to extremities, skin). The doses to the legs of radiologists have received less attention than those to the hands, however the doses may be high, due to the proximity of the legs and feet to scattered radiation. The legs can be exposed to a relatively high level of scattered radiation as the radiation in produced from scatter of the un attenuated beam from the bottom of the patient couch. The routine monitoring of extremity doses in interventional radiology is difficult due to several factors. Firstly a wide range of interventional procedures in undertaken in every radiology department, and these procedures require many different techniques, equipment and skills. This means that the position the radiologist adopts in relation to scattering medium and therefore their exposure, depends heavily on the type of procedure. As the hands which manipulate the catheters within the patient are often located close to the patients side and to the area under irradiation, the distribution of dose across the hands can be variable, with very high localised doses, making routine monitoring difficult. The purpose of this study was to determine the magnitude and distribution of dose to the hands and legs of interventional radiologists carrying out a wide range of both diagnostic and therapeutic interventional procedures. To ascertain the most effective method of monitoring the highest dose in accordance with the Basic safety standards

  16. Dosimetric considerations in treating mediastinal disease with mantle fields: Characterization of the dose under mantle blocks

    International Nuclear Information System (INIS)

    Miller, R.W.; Geijn, J. van de; Okunieff, P.

    1995-01-01

    While the rationale for using mantle fields is well understood and the prescription of these fields is straightforward, the underlying complexity of the dose distributions that result is not generally appreciated. This is especially true in the choice of lung block design, which affects the dose to both the target volume as well as to the normal lung tissue. The key to the design of optimal lung blocks is the physician's perception of the complex relationship between the geometric and dosimetric aspects of heavily modified fields, as well as how the physical and anatomical properties of the target volume and the shape of the patient's lungs relate to the images visualized on simulator films. Depth doses and cross-beam profiles of blocks ranging in width from 1 cm to 10 cm were taken using an automated beam scanning system. These data were then converted to open-quotes shadow fields.close quotes Shadow fields behave quite similarly to small, open fields in terms of x-ray-light field congruence, flatness, symmetry, and penumbra. There is a 2-3 mm rim between the edge of the block and the point at which it becomes nominally effective. The dose at the center of a block, which gives the normalization of the shadow fields, is given by a block transmission factor (BTF), which produces results in excellent agreement with measurements over a wide variety of block sizes and tissue depths. The radiation dose under shielding blocks can be considerably higher than expected, and care must be exercised when drawing blocks close to critical structures. The effects of blocks can be described in terms of normalized shadow fields, which behave similar to narrow, open fields, but with a divergence characteristic of their position relative to the radiation source. The normalization value for these fields, which gives the relative dose under the block, can be obtained from a straightforward analytical expression, the BTF. 33 refs., 9 figs., 4 tabs

  17. PET/CT-guided Interventions: Personnel Radiation Dose

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States); Hsu, Meier [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics (United States); Quinn, Brian; Dauer, Lawrence T. [Memorial Sloan-Kettering Cancer Center, Department of Medical Physics (United States); Solomon, Stephen B. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States)

    2013-08-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

  18. Reversible anaesthesia of free-ranging lions (Panthera leo in Zimbabwe

    Directory of Open Access Journals (Sweden)

    A. Fahlman

    2005-06-01

    Full Text Available The combination of medetomidine-zolazepam-tiletamine with subsequent antagonism by atipamezole was evaluated for reversible anaesthesia of free-ranging lions (Panthera leo. Twenty-one anaesthetic events of 17 free-ranging lions (5 males and 12 females, body weight 105-211 kg were studied in Zimbabwe. Medetomidine at 0.027-0.055 mg / kg (total dose 4-11 mg and zolazepam-tiletamine at 0.38-1.32 mg / kg (total dose 50-275 mg were administered i.m. by dart injection. The doses were gradually decreased to improve recovery. Respiratory and heart rates, rectal temperature and relative haemoglobin oxygen saturation (SpO2 were recorded every 15 min. Arterial blood samples were collected from 5 lions for analysis of blood gases and acid-base status. For anaesthetic reversal, atipamezole was administered i.m. at 2.5 or 5 times the medetomidine dose. Induction was smooth and all lions were anaesthetised with good muscle relaxation within 3.4-9.5 min after darting. The predictable working time was a minimum of 1 h and no additional drug doses were needed. Respiratory and heart rates and SpO2 were stable throughout anaesthesia, whereas rectal temperature changed significantly over time. Atipamezole at 2.5 times the medetomidine dose was sufficient for reversal and recoveries were smooth and calm in all lions independent of the atipamezole dose. First sign of recovery was observed 3-27 min after reversal. The animals were up walking 8-26 min after reversal when zolazepamtiletamine doses <1 mg / kg were used. In practice, a total dose of 6 mg medetomidine and 80 mg zolazepam-tiletamine and reversal with 15 mg atipamezole can be used for either sex of an adult or subadult lion. The drugs and doses used in this study provided a reliable, safe and reversible anaesthesia protocol for free-ranging lions.

  19. Heavy drinking, impulsivity and attentional narrowing following alcohol cue exposure.

    Science.gov (United States)

    Hicks, Joshua A; Fields, Sherecce; Davis, William E; Gable, Philip A

    2015-08-01

    Research shows that alcohol-related stimuli have the propensity to capture attention among individuals motivated to consume alcohol. Research has further demonstrated that impulsive individuals are especially prone to this type of attentional bias. Recently, it is suggested that alcohol cue exposure can also produce a general narrowing of attention consistent with the activation of approach motivational states. Based on previous models of addiction and recent research on the activation of approach motivational states, we predicted that impulsive individuals would demonstrate a constriction of attentional focus in response to alcohol cue exposure. Participants (n = 392) completed a task assessing attentional breadth in response to alcohol and non-alcohol cues, followed by measures of alcohol use and impulsivity. The findings revealed that impulsivity scores predicted narrowing of attentional scope following the presentation of alcohol cues for heavier drinkers but not for light drinkers. These results suggest that impulsive individuals who drink more heavily demonstrate a narrowing of attention in the presence of alcohol-related incentive cues. Implications for how these findings might account for the link between impulsivity and alcohol use and misuse are discussed.

  20. Present status of heat transfer in narrow gap rectangular channel

    International Nuclear Information System (INIS)

    Sudo, Yukio; Kaminaga, Masanori

    1990-01-01

    In the safety evaluation for research nuclear reactors, at the time of abnormal transient change and accidents, after the tripping of a primary coolant pump, such event that the flow direction of coolant in a core reverses from steady downward flow to rising flow is supposed. In this case, the coexisting convection field, in which free convection and forced convection coexist, arises in place of forced convection, and especially in the research reactors using plate type fuel like JRR-3, it is important to grasp the heat transfer characteristics in the coexisting convection field in a narrow channel. Jackson et al. proposed the heat transfer correlation equation which can be applied to wide conditions including the coexisting convection zone, but its applicability to a narrow channel has not been confirmed. Based on the experimental results, in this study, the effect that the decrease of gap exerts to the convection heat transfer characteristics reported so far was investigated. The experiment and the results are reported. In this experiment on the coexisting convection zone in a narrow gap, the effect of main flow acceleration arose sufficiently large as compared with the effect of buoyancy, and heat transfer was promoted. (K.I.)

  1. CONSTRAINING JET PRODUCTION SCENARIOS BY STUDIES OF NARROW-LINE RADIO GALAXIES

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, Marek [Nicolaus Copernicus Astronomical Center, Bartycka 18, 00-716 Warsaw (Poland); Stasinska, Grazyna [LUTH, Observatoire de Paris, CNRS, Universite Paris Diderot, Place Jules Janssen, F-92190 Meudon (France); Koziel-Wierzbowska, Dorota [Astronomical Observatory, Jagiellonian University, ul. Orla 171, 30-244 Krakow (Poland); Madejski, Greg M. [Kavli Institute for Particle Astrophysics and Cosmology, Stanford University, Stanford, CA 94305 (United States); Asari, Natalia V., E-mail: sikora@camk.edu.pl [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom)

    2013-03-01

    We study a large sample of narrow-line radio galaxies (NLRGs) with extended radio structures. Using 1.4 GHz radio luminosities L {sub 1.4}, narrow optical emission line luminosities L {sub [OIII]} and L{sub H{sub {alpha}}}, as well as black hole masses M {sub BH} derived from stellar velocity dispersions measured from the optical spectra obtained with the Sloan Digital Sky Survey, we find that (1) NLRGs cover about four decades of the Eddington ratio, {lambda} {identical_to} L {sub bol}/L {sub Edd}{proportional_to}L {sub line}/M {sub BH}; (2) L {sub 1.4}/M {sub BH} strongly correlates with {lambda}; and (3) radio loudness, R{identical_to}L{sub 1.4}/L{sub line}, strongly anti-correlates with {lambda}. A very broad range of the Eddington ratio indicates that the parent population of NLRGs includes both radio-loud quasars (RLQs) and broad-line radio galaxies (BLRGs). The correlations they obey and their high jet production efficiencies favor a jet production model which involves the so-called magnetically choked accretion scenario. In this model, production of the jet is dominated by the Blandford-Znajek mechanism, and the magnetic fields in the vicinity of the central black hole are confined by the ram pressure of the accretion flow. Since large net magnetic flux accumulated in central regions of the accretion flow required by the model can take place only via geometrically thick accretion, we speculate that the massive, 'cold' accretion events associated with luminous emission-line active galactic nucleus can be accompanied by an efficient jet production only if preceded by a hot, very sub-Eddington accretion phase.

  2. Nonstationary Narrow-Band Response and First-Passage Probability

    DEFF Research Database (Denmark)

    Krenk, Steen

    1979-01-01

    The notion of a nonstationary narrow-band stochastic process is introduced without reference to a frequency spectrum, and the joint distribution function of two consecutive maxima is approximated by use of an envelope. Based on these definitions the first passage problem is treated as a Markov po...

  3. Thermal tuning On narrow linewidth fiber laser

    Science.gov (United States)

    Han, Peiqi; Liu, Tianshan; Gao, Xincun; Ren, Shiwei

    2010-10-01

    At present, people have been dedicated to high-speed and large-capacity optical fiber communication system. Studies have been shown that optical wavelength division multiplexing (WDM) technology is an effective means of communication to increase the channel capacity. Tunable lasers have very important applications in high-speed, largecapacity optical communications, and distributed sensing, it can provide narrow linewidth and tunable laser for highspeed optical communication. As the erbium-doped fiber amplifier has a large gain bandwidth, the erbium-doped fiber laser can be achieved lasing wavelength tunable by adding a tunable filter components, so tunable filter device is the key components in tunable fiber laser.At present, fiber laser wavelength is tuned by PZT, if thermal wavelength tuning is combined with PZT, a broader range of wavelength tuning is appearance . Erbium-doped fiber laser is used in the experiments,the main research is the physical characteristics of fiber grating temperature-dependent relationship and the fiber grating laser wavelength effects. It is found that the fiber laser wavelength changes continuously with temperature, tracking several temperature points observed the self-heterodyne spectrum and found that the changes in spectra of the 3dB bandwidth of less than 1kHz, and therefore the fiber laser with election-mode fiber Bragg grating shows excellent spectral properties and wavelength stability.

  4. Omnidirectional narrow optical filters for circularly polarized light in a nanocomposite structurally chiral medium.

    Science.gov (United States)

    Avendaño, Carlos G; Palomares, Laura O

    2018-04-20

    We consider the propagation of electromagnetic waves throughout a nanocomposite structurally chiral medium consisting of metallic nanoballs randomly dispersed in a structurally chiral material whose dielectric properties can be represented by a resonant effective uniaxial tensor. It is found that an omnidirectional narrow pass band and two omnidirectional narrow band gaps are created in the blue optical spectrum for right and left circularly polarized light, as well as narrow reflection bands for right circularly polarized light that can be controlled by varying the light incidence angle and the filling fraction of metallic inclusions.

  5. The response of mouse skin to multiple small doses of radiation

    International Nuclear Information System (INIS)

    Denekamp, J.; Harris, S.R.

    1975-01-01

    The response of mouse skin has been tested by irradiating the foot of albino mice and scoring erythema and desquamation during the following month. Multiple small doses of 150, 250 and 350 rad have been given 'daily', and the test dose necessary to achieve a given reaction has been determined one day after the last small fraction. This test dose has been compared with the single dose necessary to produce the same reaction level in previously untreated mice, in order to determine the ratio of the slopes of the dose-response curve at low and high doses: Slope ratio = (single dose - test dose)/total fractionated priming dose. In three separate experiments the slope ratio decreased as the dose per fraction was reduced from 350 to 150 rad. This conflicts with the data of Dutreix et al, who found a constant slope ratio over this dose range. The present data are compared with those obtained by Denekamp using 4, 9 and 14 fractions of 300 rad and by Douglas et al, using the same experimental technique, over the dose range 45 to 200 rad/fraction. In addition, the results from multifraction experiments in which equal dose increments were administered until the requisite skin reaction was achieved are also analysed in terms of their slope ratio (Fowler et al. Douglas et al). When all these results are plotted it is impossible to be sure whether the slope ratio is decreasing over the range 300 to 45 rad per fraction, although it seems likely. Most of the values at low doses lie in the range 0.15 to 0.25, indicating that at low doses the radiation is only 15 to 25% as effective per rad in causing cell death as at higher doses. (author)

  6. Quality Control in Mammography: Image Quality and Patient Doses

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  7. Narrow Networks On The Health Insurance Marketplaces: Prevalence, Pricing, And The Cost Of Network Breadth.

    Science.gov (United States)

    Dafny, Leemore S; Hendel, Igal; Marone, Victoria; Ody, Christopher

    2017-09-01

    Anecdotal reports and systematic research highlight the prevalence of narrow-network plans on the Affordable Care Act's health insurance Marketplaces. At the same time, Marketplace premiums in the period 2014-16 were much lower than projected by the Congressional Budget Office in 2009. Using detailed data on the breadth of both hospital and physician networks, we studied the prevalence of narrow networks and quantified the association between network breadth and premiums. Controlling for many potentially confounding factors, we found that a plan with narrow physician and hospital networks was 16 percent cheaper than a plan with broad networks for both, and that narrowing the breadth of just one type of network was associated with a 6-9 percent decrease in premiums. Narrow-network plans also have a sizable impact on federal outlays, as they depress the premium of the second-lowest-price silver plan, to which subsidy amounts are linked. Holding all else constant, we estimate that federal subsidies would have been 10.8 percent higher in 2014 had Marketplaces required all plans to offer broad provider networks. Narrow networks are a promising source of potential savings for other segments of the commercial insurance market. Project HOPE—The People-to-People Health Foundation, Inc.

  8. Dose assessment of an accidental exposure at the IPNS

    International Nuclear Information System (INIS)

    Campos Torres, M.M.

    1995-02-01

    Seven different methods were used to estimate the dose rate to a female worker who was accidentally exposed in the neutron PHOENIX beamline at the IPNS. Theoretical and measured entrance dose ranged from 550 mrem/min to 2850 mrem/min. Theoretical estimates were based on a Monte Carlo simulation of a spectrum provided by IPNS (Crawford Spectrum). Dose measurements were made with TLDs on phantoms and with ionization chambers in a water phantom. Estimates of the whole body total effective dose equivalent (TEDE) rate ranged from 5.2 mrem/min to 840 mrem/min. Assumed and measured quality factors ranged from 2.6 to 11.8. Cytogenetic analyses of blood samples detected no positive exposure. The recommended TEDE rate was 158 mrem/min. The TEDE was 750 mrem

  9. Narrow band wavelength selective filter using grating assisted single ring resonator

    Energy Technology Data Exchange (ETDEWEB)

    Prabhathan, P., E-mail: PPrabhathan@ntu.edu.sg; Murukeshan, V. M. [Centre for Optical and Laser Engineering (COLE), School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore)

    2014-09-15

    This paper illustrates a filter configuration which uses a single ring resonator of larger radius connected to a grating resonator at its drop port to achieve single wavelength selectivity and switching property with spectral features suitable for on-chip wavelength selection applications. The proposed configuration is expected to find applications in silicon photonics devices such as, on-chip external cavity lasers and multi analytic label-free biosensors. The grating resonator has been designed for a high Q-factor, high transmittivity, and minimum loss so that the wavelength selectivity of the device is improved. The proof-of-concept device has been demonstrated on a Silicon-on-Insulator (SOI) platform through electron beam lithography and Reactive Ion Etching (RIE) process. The transmission spectrum shows narrow band single wavelength selection and switching property with a high Free Spectral Range (FSR) ∼60 nm and side band rejection ratio >15 dB.

  10. Single frequency narrow linewidth 2 micron laser, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA needs narrow linewidth lasers in the 1.5 or 2 micron wavelength regime for coherent Lidar applications. The laser should be tunable by several nm and frequency...

  11. Characterization of 60Co dose distribution using BEAMnrc Monte Carlo code

    International Nuclear Information System (INIS)

    Abuissa, M. I. M.

    2012-12-01

    In this study BEAMnrc based on EGSnrc as Monte Carlo code has been used for modeling and simulating 6 0C o machine in radioisotope centre of Khartoum (RICK), Two fields size ( 5 cm x 5 cm and 35 cm x 35 cm), were been studied, to define the characterization of 6 0C o machine and to investigate the effect of increasing the surface to skin distance (SSD) on the 6 0C o machine properties, e.g.; beam profile and percentage depth dose (Pdd). For the narrow field size there is a small change observed in the curves representing beam profile and the percentage depth dose when increasing the distance by 5 cm, for the wide fi ld size there relatively clear different in curves. The study results been compared with other previous studies and clear consistence observed. (Author)

  12. Acute pancreatitis related to therapeutic dosing with colchicine: a case report

    Directory of Open Access Journals (Sweden)

    Ting Joseph

    2007-08-01

    Full Text Available Abstract Background Colchicine is used in the treatment and prophylaxis of gout. It possesses a narrow therapeutic window, frequently resulting in dose-limiting gastrointestinal side-effects such as diarrhoea and emesis. As colchicine is a cellular anti-mitotic agent, the most serious effects include myelosuppression, myoneuropathy and multiple organ failure. This occurs with intentional overdose or with therapeutic dosing in patients with reduced clearance of colchicine due to pre-existing renal or hepatic impairment. Acute pancreatitis has rarely been reported, and only in association with severe colchicine overdose accompanied by multi-organ failure. Case presentation We report a case of acute pancreatitis without other organ toxicity related to recent commencement of colchicine for acute gout, occurring in an elderly male with pre-existing renal impairment. Conclusion 1 Colchicine should be used with care in elderly patients or patients with impaired renal function. 2 Aside from myelosuppression, myoneuropathy and multiple organ failure, colchicine may now be associated with acute pancreatitis even with therapeutic dosing; this has not previously being reported.

  13. Dose survey of pediatric and adult patients in Sudan

    International Nuclear Information System (INIS)

    Mohamadain, K.E.M.; Azevedo, A.C.P.; And others

    2006-01-01

    A survey of radiation doses to children and adults from diagnostic radiography has been carried out in seven hospitals in Sudan. In four hospitals only pediatric examinations were died. In two hospitals only adult patients were recorded and in one hospital both kinds of patients (pediatric and adults) were evaluated. For pediatric patients only chest x-ray examination was evaluated and children were divided according to age ranges: from (0-1) and 5) years for chest AP only and from (5-10) and (10-15) for chest PA. For adult patients the examinations were chest AP and PA, abdomen AP and skull AP and PA. Entrance Surface Dose SD) and the Effective Dose (E) were calculated using the Dose Cal software. The mean ESD r children, measured in p.Gy, ranged from (45-53) and (53-56) for (0-1) and (1-5) years, respectively and from (55-71) and (68-85) for (5-10) and (10-15) years, respectively. In two of le pediatric hospitals the mean ESD values were greater than the CEC Reference Dose Levels. In El bulk and Si nar hospitals the values ranged from 167-261 and 186-308 μGy for the age ranges (0-1) and (1-5) respectively and 167-194 and 279-312 μGy for the age ranges of (5-10) and (10-15) respectively. For adult patients the ESD and E dose values evaluated in Alfisal hospital presented values comparable with the CEC Reference Dose Level. However for Alshorta hospital the values were higher for the chest AP and PA with results for ESD 0.446 and 0.551 mGy respectively

  14. Narrow band quantitative and multivariate electroencephalogram analysis of peri-adolescent period.

    Science.gov (United States)

    Martinez, E I Rodríguez; Barriga-Paulino, C I; Zapata, M I; Chinchilla, C; López-Jiménez, A M; Gómez, C M

    2012-08-24

    The peri-adolescent period is a crucial developmental moment of transition from childhood to emergent adulthood. The present report analyses the differences in Power Spectrum (PS) of the Electroencephalogram (EEG) between late childhood (24 children between 8 and 13 years old) and young adulthood (24 young adults between 18 and 23 years old). The narrow band analysis of the Electroencephalogram was computed in the frequency range of 0-20 Hz. The analysis of mean and variance suggested that six frequency ranges presented a different rate of maturation at these ages, namely: low delta, delta-theta, low alpha, high alpha, low beta and high beta. For most of these bands the maturation seems to occur later in anterior sites than posterior sites. Correlational analysis showed a lower pattern of correlation between different frequencies in children than in young adults, suggesting a certain asynchrony in the maturation of different rhythms. The topographical analysis revealed similar topographies of the different rhythms in children and young adults. Principal Component Analysis (PCA) demonstrated the same internal structure for the Electroencephalogram of both age groups. Principal Component Analysis allowed to separate four subcomponents in the alpha range. All these subcomponents peaked at a lower frequency in children than in young adults. The present approaches complement and solve some of the incertitudes when the classical brain broad rhythm analysis is applied. Children have a higher absolute power than young adults for frequency ranges between 0-20 Hz, the correlation of Power Spectrum (PS) with age and the variance age comparison showed that there are six ranges of frequencies that can distinguish the level of EEG maturation in children and adults. The establishment of maturational order of different frequencies and its possible maturational interdependence would require a complete series including all the different ages.

  15. Analysis of occupational doses of workers on the dose registry of the Federal Radiation Protection Service in 2000 and 2001

    International Nuclear Information System (INIS)

    Ogundare, F.O.; Balogun, F.A.

    2003-01-01

    In 2000 and 2001 about 279 and 221 radiation workers, respectively, were monitored by the Federal Radiation Protection Service, University of Ibadan, in Nigeria. The distribution of the occupational doses shows that the majority of workers received doses below 4 mSv in each of the two years. The radiation workers in the two years are classified into two occupational categories: medicine and industry. The mean annual effective doses, collective doses and the collective dose distribution ratios for workers in each category and the entire monitored workers were calculated. The mean annual effective doses were compared with their corresponding worldwide values quoted by UNSCEAR. In each of the two years, a few workers in industry received doses higher than 50 mSv. The collective dose distribution ratio was found to be about 0.49, which is very close to the highest value of 0.5 in the range of values considered by UNSCEAR as normal for this parameter. This suggests that extra measures have to be taken, particularly in industry, to ensure that the proportion of workers at risk does not go outside this normal range. The occupational doses were also modelled by both the log-normal and Weibull distributions. Both distributions were found to describe the data in almost the same way. (author)

  16. Analytical calculation of central-axis dosimetric data for a dedicated 6-MV radiosurgery linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Yang, James N.; Pino, Ramiro [Department of Radiation Physics, Unit 94, University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030 (United States); Department of Radiology, Baylor College of Medicine and Methodist Hospital, Houston, Texas 77030 (United States)

    2008-10-15

    Narrow beams are extensively used in stereotactic radiosurgery. The accuracy of treatment planning dose calculation depends largely on how well the dosimetric data are measured during the machine commissioning. Narrow beams are characterized by the lack of lateral electronic equilibrium. The lateral electronic disequilibrium in the radiation field and detector's finite size are likely to compromise the accuracy in dose measurements in these beams. This may have a profound impact on outcome in patients who undergo stereotactic radiosurgery. To confirm the measured commissioning data for a dedicated 6-MV linear accelerator-based radiosurgery system, we developed an analytical model to calculate the narrow photon beam central-axis dose. This model is an extension of a previously reported method of Nizin and Mooij for the calculation of the absorbed dose under lateral electronic disequilibrium conditions at depth of d{sub max} or greater. The scatter factor and tissue-maximum ratio were calculated for narrow beams using the parametrized model and compared to carefully measured results for the same beams. For narrow beam radii ranging from 0.2 to 1.5 cm, the differences between the analytical and measured scatter factors were no greater than 1.4%. In addition, the differences between the analytical and measured tissue-maximum ratios were within 3.3% for regions greater than the maximum dose depth. The estimated error of this analytical calculation was less than 2%, which is sufficient to validate measurement results.

  17. VKORC1 polymorphisms and warfarin maintenance dose in population of Sakha (Yakuts).

    Science.gov (United States)

    Chertovskikh, Y V; Malova, E U; Maksimova, N R; Popova, N V; Sychev, D A

    2015-01-01

    Vitamin K antagonists are effective in the prevention and treatment of thromboembolic disorders. Warfarin is one of the most widely prescribed vitamin K antagonists in the world [1, 2]. It has a narrow therapeutic range and a given dose may result in a large inter-individual variation of response. Insufficient dose may fail to prevent thromboembolism, while an overdose increases the risk of bleeding. Patient-specific factors (e.g., age, body size, race, concurrent diseases, and medications) explain some of the variability in warfarin dosage, but genetic factors influencing warfarin response explain a significantly higher proportion of this variability [3]. Molecular analysis of the gene that encodes the target enzyme vitamin K epoxide reductase complex 1 (VKORC1) strongly suggests that its genetic variations greatly affect the individual response to oral anticoagulants [4-7]. To evaluate effects of VKORC1 polymorphisms on warfarin dose excess anticoagulation (INR >4.0) in the population of Sakha (S) patients. 53 patients (29-women, 24-men) with atrial fibrillation (68%), congestive heart failure (60%), hypertension (49%) and cardiac valve replacement (26%) were recruited. The age range was 26-80 years, with a mean age of 62.87 ± 12.57 years.International normalized ratio and plasma warfarin concentrations were determined. Genotyping was carried out by RT-PCR (real-time PCR). The three genetic polymorphisms of the gene VKORC1 G3673A (rs9923231) were studied: normal (GG), heterozygous (GA) and homozygous (AA). Fisher exact probability test and chi-square test (with Yates correction) were applied to compare data among the AA and GG + GA groups; also Mann-Whitney test was used. The median maintenance daily dose of warfarin among AA carriers was 3.0 mg/day [1.25-7.5 mg], while in GG and GA patients it was 3.13 mg/day [1.88-7.92 mg]. The mean daily warfarin dosage was higher in GG and GA genotype carriers 4.05 mg/day (SD ± 1.7) than in patients with AA genotype 3

  18. Low level dose induced chromosome aberrations in human blood lymphocytes

    International Nuclear Information System (INIS)

    Pohl-Rueling, J.

    1992-01-01

    Unstable structural aberrations in chromosomes of human blood lymphocytes cannot be used as biological dosemeters in the low dose range, when extrapolating from high doses using a linear dose response, as required by the original formula of the dual radiation action theory. A survey is given of experimental dose-response curves of chromosome aberrations, obtained in investigations not only by this institute, in cooperation with many other laboratories, but also by various authors in different areas of the world. The results are not compatible with the predicted linear dose relationships at in vivo dose ranges up to 30 mGy.y -1 . The aberration frequencies rise sharply with dose within the normal environmental exposure up to about twice that level. At higher doses, aberration frequencies increase less rapidly and reach a plateau. Some in vitro experiments of various authors with higher doses of low LET radiations, up to about 400 mGy have found dose responses with steps. (author)

  19. Sibutramine in weight control: a dose-ranging, efficacy study.

    Science.gov (United States)

    Weintraub, M; Rubio, A; Golik, A; Byrne, L; Scheinbaum, M L

    1991-09-01

    We tested the safety and efficacy of sibutramine, 5 and 20 mg, and placebo on weight loss. Medication was added to caloric restriction, behavior modification, and exercise in a parallel-group, double-blind clinical trial. Participants were 130% to 180% of ideal body weight and in good health. The study lasted 12 weeks over Thanksgiving, Christmas, and New Year's Day. Weight loss during 8 weeks of study medication was: placebo, 1.4 +/- 2.1 kg (n = 19); 5 mg sibutramine, 2.9 +/- 2.3 kg (n = 18); and 20 mg sibutramine, 5.0 +/- 2.7 kg (n = 18) (p less than 0.05 sibutramine, 5 and 20 mg, versus placebo; p less than 0.05 sibutramine, 20 mg versus 5 mg). There is a significant dose-effect relationship. Five participants left the study before completion, all because of adverse events; placebo (one patient), 5 mg sibutramine (one patient), and 20 mg sibutramine (three patients). Sleep difficulties were noted by eight participants (20 mg sibutramine, seven patients; 5 mg, one patient; and placebo, no patients). Six of 21 participants receiving 20 mg complained of irritability, unusual impatience, or "excitation." Sibutramine, 5 and 20 mg, added to a multimodal program assisted participants in losing weight.

  20. Performance of commercial platforms for rapid genotyping of polymorphisms affecting warfarin dose.

    Science.gov (United States)

    King, Cristi R; Porche-Sorbet, Rhonda M; Gage, Brian F; Ridker, Paul M; Renaud, Yannick; Phillips, Michael S; Eby, Charles

    2008-06-01

    Initiation of warfarin therapy is associated with bleeding owing to its narrow therapeutic window and unpredictable therapeutic dose. Pharmacogenetic-based dosing algorithms can improve accuracy of initial warfarin dosing but require rapid genotyping for cytochrome P-450 2C9 (CYP2C9) *2 and *3 single nucleotide polymorphisms (SNPs) and a vitamin K epoxide reductase (VKORC1) SNP. We evaluated 4 commercial systems: INFINITI analyzer (AutoGenomics, Carlsbad, CA), Invader assay (Third Wave Technologies, Madison, WI), Tag-It Mutation Detection assay (Luminex Molecular Diagnostics, formerly Tm Bioscience, Toronto, Canada), and Pyrosequencing (Biotage, Uppsala, Sweden). We genotyped 112 DNA samples and resolved any discrepancies with bidirectional sequencing. The INFINITI analyzer was 100% accurate for all SNPs and required 8 hours. Invader and Tag-It were 100% accurate for CYP2C9 SNPs, 99% accurate for VKORC1 -1639/3673 SNP, and required 3 hours and 8 hours, respectively. Pyrosequencing was 99% accurate for CYP2C9 *2, 100% accurate for CYP2C9 *3, and 100% accurate for VKORC1 and required 4 hours. Current commercial platforms provide accurate and rapid genotypes for pharmacogenetic dosing during initiation of warfarin therapy.

  1. Tissue-phantom dose ratio R(t, F) in irradiation planning. 2

    International Nuclear Information System (INIS)

    Hegewald, H.

    1986-01-01

    The principles for measuring doses are represented to complete the developed tissue-phantom dose ratio R(t, F). The functional dependence of the tissue-phantom dose ratio on the field size results from the different spectral energy distribution in the buildup range compared to greater depths. This once more illustrates the demand, to move the calibration and reference depths into greater depths than the dose maximum depth on account of a high precision. The scattering factors and their dependence on the type of collimator are represented and tables are made up for practical use. In a supplement the derivations of the equation systems are given, to find out the tissue-phantom dose ratio by computation and the correspondence is tested. The measurements are more relevant in the megavolt range since dose values typically for the equipment are measured in the buildup range and depth dose tables are not available in the required completeness. (author)

  2. Motion as a perturbation: Measurement-guided dose estimates to moving patient voxels during modulated arc deliveries

    Energy Technology Data Exchange (ETDEWEB)

    Feygelman, Vladimir; Zhang, Geoffrey; Hunt, Dylan; Opp, Daniel [Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States); Stambaugh, Cassandra [Department of Physics, University of South Florida, Tampa, Florida 33612 (United States); Wolf, Theresa K. [Live Oak Technologies LLC, Kirkwood, Missouri 63122 (United States); Nelms, Benjamin E. [Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States)

    2013-02-15

    Purpose: To present a framework for measurement-guided VMAT dose reconstruction to moving patient voxels from a known motion kernel and the static phantom data, and to validate this perturbation-based approach with the proof-of-principle experiments. Methods: As described previously, the VMAT 3D dose to a static patient can be estimated by applying a phantom measurement-guided perturbation to the treatment planning system (TPS)-calculated dose grid. The fraction dose to any voxel in the presence of motion, assuming the motion kernel is known, can be derived in a similar fashion by applying a measurement-guided motion perturbation. The dose to the diodes in a helical phantom is recorded at 50 ms intervals and is transformed into a series of time-resolved high-density volumetric dose grids. A moving voxel is propagated through this 4D dose space and the fraction dose to that voxel in the phantom is accumulated. The ratio of this motion-perturbed, reconstructed dose to the TPS dose in the phantom serves as a perturbation factor, applied to the TPS fraction dose to the similarly situated voxel in the patient. This approach was validated by the ion chamber and film measurements on four phantoms of different shape and structure: homogeneous and inhomogeneous cylinders, a homogeneous cube, and an anthropomorphic thoracic phantom. A 2D motion stage was used to simulate the motion. The stage position was synchronized with the beam start time with the respiratory gating simulator. The motion patterns were designed such that the motion speed was in the upper range of the expected tumor motion (1-1.4 cm/s) and the range exceeded the normally observed limits (up to 5.7 cm). The conformal arc plans for X or Y motion (in the IEC 61217 coordinate system) consisted of manually created narrow (3 cm) rectangular strips moving in-phase (tracking) or phase-shifted by 90 Degree-Sign (crossing) with respect to the phantom motion. The XY motion was tested with the computer-derived VMAT

  3. Motion as a perturbation: Measurement-guided dose estimates to moving patient voxels during modulated arc deliveries

    International Nuclear Information System (INIS)

    Feygelman, Vladimir; Zhang, Geoffrey; Hunt, Dylan; Opp, Daniel; Stambaugh, Cassandra; Wolf, Theresa K.; Nelms, Benjamin E.

    2013-01-01

    Purpose: To present a framework for measurement-guided VMAT dose reconstruction to moving patient voxels from a known motion kernel and the static phantom data, and to validate this perturbation-based approach with the proof-of-principle experiments. Methods: As described previously, the VMAT 3D dose to a static patient can be estimated by applying a phantom measurement-guided perturbation to the treatment planning system (TPS)-calculated dose grid. The fraction dose to any voxel in the presence of motion, assuming the motion kernel is known, can be derived in a similar fashion by applying a measurement-guided motion perturbation. The dose to the diodes in a helical phantom is recorded at 50 ms intervals and is transformed into a series of time-resolved high-density volumetric dose grids. A moving voxel is propagated through this 4D dose space and the fraction dose to that voxel in the phantom is accumulated. The ratio of this motion-perturbed, reconstructed dose to the TPS dose in the phantom serves as a perturbation factor, applied to the TPS fraction dose to the similarly situated voxel in the patient. This approach was validated by the ion chamber and film measurements on four phantoms of different shape and structure: homogeneous and inhomogeneous cylinders, a homogeneous cube, and an anthropomorphic thoracic phantom. A 2D motion stage was used to simulate the motion. The stage position was synchronized with the beam start time with the respiratory gating simulator. The motion patterns were designed such that the motion speed was in the upper range of the expected tumor motion (1–1.4 cm/s) and the range exceeded the normally observed limits (up to 5.7 cm). The conformal arc plans for X or Y motion (in the IEC 61217 coordinate system) consisted of manually created narrow (3 cm) rectangular strips moving in-phase (tracking) or phase-shifted by 90° (crossing) with respect to the phantom motion. The XY motion was tested with the computer-derived VMAT MLC

  4. Assessment of atherosclerotic luminal narrowing of coronary arteries based on morphometrically generated visual guides.

    Science.gov (United States)

    Barth, Rolf F; Kellough, David A; Allenby, Patricia; Blower, Luke E; Hammond, Scott H; Allenby, Greg M; Buja, L Maximilian

    Determination of the degree of stenosis of atherosclerotic coronary arteries is an important part of postmortem examination of the heart, but, unfortunately, estimation of the degree of luminal narrowing can be imprecise and tends to be approximations. Visual guides can be useful to assess this, but earlier attempts to develop such guides did not employ digital technology. Using this approach, we have developed two computer-generated morphometric guides to estimate the degree of luminal narrowing of atherosclerotic coronary arteries. The first is based on symmetric or eccentric circular or crescentic narrowing of the vessel lumen and the second on either slit-like or irregularly shaped narrowing of the vessel lumens. Using the Aperio ScanScope XT at a magnification of 20× we created digital whole-slide images of 20 representative microscopic cross sections of the left anterior descending (LAD) coronary artery, stained with either hematoxylin and eosin (H&E) or Movat's pentachrome stain. These cross sections illustrated a variety of luminal profiles and degrees of stenosis. Three representative types of images were selected and a visual guide was constructed with Adobe Photoshop CS5. Using the "Scale" and "Measurement" tools, we created a series of representations of stenosis with luminal cross sections depicting 20%, 40%, 60%, 70%, 80%, and 90% occlusion of the LAD branch. Four pathologists independently reviewed and scored the degree of atherosclerotic luminal narrowing based on our visual guides. In addition, digital technology was employed to determine the degree of narrowing by measuring the cross-sectional area of the 20 microscopic sections of the vessels, first assuming no narrowing and then comparing this to the percent of narrowing determined by precise measurement. Two of the observers were very experienced general autopsy pathologists, one was a first-year pathology resident on his first rotation on the autopsy service, and the fourth observer was a

  5. PET/CT-guided Interventions: Personnel Radiation Dose

    International Nuclear Information System (INIS)

    Ryan, E. Ronan; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P.; Hsu, Meier; Quinn, Brian; Dauer, Lawrence T.; Solomon, Stephen B.

    2013-01-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0–0.13) mSv for the primary operator, 0.01 (range 0–0.05) mSv for the nurse anesthetist, and 0.02 (range 0–0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0–0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient

  6. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    International Nuclear Information System (INIS)

    Cunha, Elisete L.; Schimitberger, Thiago

    2017-01-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm -1 and 3271 cm -1 , with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  7. Investigation of PBAT dosimetric properties for high gamma dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Elisete L.; Schimitberger, Thiago, E-mail: elisete.cunha@cdtn.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Oliveira, Cristiana M.; Faria, Luiz O., E-mail: farialo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Poly(butylene adipate-co-terephthalate) (PBAT) is an aliphatic-aromatic copolyester which is biodegradable. It is a non-photoluminescent copolyester that becomes photoluminescent after previous exposure to gamma doses higher than 100 kGy. After the previous high energy irradiation, the material shows the highest photo-stimulated luminescence emission when excited with a LED source at wavelengths ranging from 370 to 405 nm. In this work we investigated the enhancement of the photoluminescence (PL) and dosimetric properties of PBAT, after exposure to high doses of gamma radiation ranging from 50 to 4,000 kGy. In this investigation we demonstrate that increasing the PBAT film thickness by 100 μm enhances the PL output by 3.5 times, when irradiated with 500 kGy. Also, besides the already known color green brightness, the PL intensity can also be used for high dose dosimetry purposes for doses ranging from 50 to 750 kGy. The FTIR analysis has demonstrated that the there is a linear relationship between peak intensity and dose for doses ranging from 100 and 2,000 kGy for the absorbance peaks at 3,241 cm{sup -1} and 3271 cm{sup -1}, with linear correlation coefficients of 0.9981 and 0.9992, respectively. The results indicate that PBAT has great potential for applications in bio-imaging devices and high gamma dose dosimetry. (author)

  8. Assessment of narrow angles by gonioscopy, Van Herick method and anterior segment optical coherence tomography.

    Science.gov (United States)

    Park, Seong Bae; Sung, Kyung Rim; Kang, Sung Yung; Jo, Jung Woo; Lee, Kyoung Sub; Kook, Michael S

    2011-07-01

    To evaluate anterior chamber (AC) angles using gonioscopy, Van Herick technique and anterior segment optical coherence tomography (AS-OCT). One hundred forty-eight consecutive subjects were enrolled. The agreement between any two of three diagnostic methods, gonioscopy, AS-OCT and Van Herick, was calculated in narrow-angle patients. The area under receiver-operating characteristic curves (AUC) for discriminating between narrow and open angles determined by gonioscopy was calculated in all participants for AS-OCT parameter angle opening distance (AOD), angle recess area, trabecular iris surface area and anterior chamber depth (ACD). As a subgroup analysis, capability of AS-OCT parameters for detecting angle closure defined by AS-OCT was assessed in narrow-angle patients. The agreement between the Van Herick method and gonioscopy in detecting angle closure was excellent in narrow angles (κ = 0.80, temporal; κ = 0.82, nasal). However, agreement between gonioscopy and AS-OCT and between the Van Herick method and AS-OCT was poor (κ = 0.11-0.16). Discrimination capability of AS-OCT parameters between open and narrow angles determined by gonioscopy was excellent for all AS-OCT parameters (AUC, temporal: AOD500 = 0.96, nasal: AOD500 = 0.99). The AUCs for detecting angle closure defined by AS-OCT image in narrow angle subjects was good for all AS-OCT parameters (AUC, 0.80-0.94) except for ACD (temporal: ACD = 0.70, nasal: ACD = 0.63). Assessment of narrow angles by gonioscopy and the Van Herick technique showed good agreement, but both measurements revealed poor agreement with AS-OCT. The angle closure detection capability of AS-OCT parameters was excellent; however, it was slightly lower in ACD.

  9. Influence of dose, dose rate, and radiation quality on radiation carcinogenesis and life shortening in RFM and BALB/C mice

    International Nuclear Information System (INIS)

    Ullrich, R.L.; Storer, J.B.

    1978-01-01

    The effects produced by 137 Cs gamma rays delivered at a high (45 rads/min) or intermediate (8.2 rads/day) dose rate and the effect of fission neutrons at a high (25 rads/min) and low (1 rad/day) rate in a population of nearly 30,000 RFM and 11,000 BALB/c mice have been studied. Gamma ray doses ranged from 10 to 400 rads with the RFM's and from 50-400 rads with the BALB/c's, while neutron doses ranged from 5 to 200 rads with both strains. The present paper will present an overview of these data and the general findings while subsequent publications will present detailed analyses of each aspect. A variety of neoplasms were sensitive to induction after radiation exposure, including tumors of both reticular tissue origin (leukemia, lymphoma, etc.) and solid tumors. For the RFM, thymic lymphomas were the dominant reticular tissue neoplasm while the majority of solid tumors were either lung adenomas or fit into the broad category of endocrine related tumors, including ovarian, pituitary, harderian, and uterine tumors. The BALB/c was much less sensitive to induction of reticular tissue neoplasms. The tumors that were most sensitive to induction included malignant lung carcinomas, mammary adenocarcinomas and ovarian tumors. In general for both life shortening and tumor induction after gamma ray exposures, when the low to intermediate dose range was sufficiently defined, linearity could be rejected and a dose squared or linear-dose squared relationship adequately fit the data. For neutron exposures, on the other hand, linear relationships were the general finding. The RBE for neutrons varied with tumor type and total dose level. For gamma ray irradiation, the intermediate dose rate resulted in a decreased effectiveness in all cases, while for neutron exposures the dose rate relationships were more complex

  10. PERSPECTIVES OF UKRAINIAN RAILWAY TOURISM DEVELOPMENT ON NARROW-GAUGE LINES OF ZAKARPATTIA

    Directory of Open Access Journals (Sweden)

    V. G. Kuznetsov

    2015-07-01

    Full Text Available Purpose.The purpose of the paper is: (1 the definition of perspectives development of Ukrainian railway tourism on the narrow gauge lines of Zakarpattia; 2 technical condition analysis of Borzhava narrow gauge railway for the project to restore the effective functioning of mountain railways track, width 750 mm in the Carpathian region, with the possibility of their accession to the distributed travel network; 3 the study of the modern state and tendencies of development of tourist industry of Ukraine and the passenger economy of national railways; 4 clarification of the role and place of the railway tourism in the transportation system. Methodology. The expert group has carried out field inspections and field investigations of facilities track facilities and passenger infrastructure, rolling stock and ancillary industries involved in the functioning narrow-gauge railway. It was estimated the overall technical condition of the railway track and engineering structures section of narrow-gauge Railways in the Carpathian region. Findings. In the framework of on-site examinations of the expert group found that the objects of tracks, passenger and freight infrastructure, rolling stock and ancillary industries involved in the operation of narrow-gauge Railways are in poor condition and require significant updates and major repairs. But the routes of passenger trains remain fit for participation in the project of development of railway tourism of Ukraine Originality. For the first time the state of the narrow-gauge railway for further implementation of the project on the development of rail tourism in Ukraine was realized. The analysis of foreign experience of organization of railway tourism has been carried out. The modern state and tendencies of development of tourist industry of Ukraine was studied, the factors of competitiveness of rail transport for providing tourist transport in Ukraine were identified and systematized.Practical value. The recovery

  11. Experimental research on flow instability in vertical narrow annuli

    Institute of Scientific and Technical Information of China (English)

    WU Geping; QIU Suizheng; SU Guanghui; JIA Dounan

    2007-01-01

    A narrow annular test section of 1.5mm gap and 1800mm length was designed and manufactured, with good tightness and insulation. Experiments were carried out to investigate characteristics of flow instability of forced-convection in vertical narrow annuli. Using distilled water as work fluid, the experiments were conducted at pressures of 1.0~3.0 MPa, mass flow rates of 3.0~25 kg/h, heating power of 3.0~ 6.5kW and inlet fluid temperature of 20 ℃, 40 ℃ or 60℃. It was found that flow instability occured with fixed inlet condition and heating power when mass flow rate was below a special value. Effects of inlet subcooling, system pressure and mass flow rate on the system behavior were studied and the instability region was given.

  12. Paradigm shift in LUNG SBRT dose calculation associated with Heterogeneity correction; Cambio de paradigma en SBRT pulmonar asociada al calculo de dosis con correccion de heterogeneidad

    Energy Technology Data Exchange (ETDEWEB)

    Zucca Aparicio, D.; Perez Moreno, J. M.; Fernandez Leton, P.; Garcia Ruiz-Zorrilla, J.; Pinto Monedero, M.; Marti Asensjo, J.; Alonso Iracheta, L.

    2015-07-01

    Treatment of lung injury SBRT requires great dosimetric accuracy, the increasing clinical importance of dose calculation heterogeneities introducing algorithms that adequately model the transport of particles narrow beams in media of low density, as with Monte Carlo calculation. (Author)

  13. Radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Cohnen, M.; Kemper, J.; Moedder, U.; Moebes, O.; Pawelzik, J.

    2002-01-01

    The aim of this study was to compare radiation exposure in panoramic radiography (PR), dental CT, and digital volume tomography (DVT). An anthropomorphic Alderson-Rando phantom and two anatomical head phantoms with thermoluminescent dosimeters fixed at appropriate locations were exposed as in a dental examination. In PR and DVT, standard parameters were used while variables in CT included mA, pitch, and rotation time. Image noise was assessed in dental CT and DVT. Radiation doses to the skin and internal organs within the primary beam and resulting from scatter radiation were measured and expressed as maximum doses in mGy. For PR, DVT, and CT, these maximum doses were 0.65, 4.2, and 23 mGy. In dose-reduced CT protocols, radiation doses ranged from 10.9 to 6.1 mGy. Effective doses calculated on this basis showed values below 0.1 mSv for PR, DVT, and dose-reduced CT. Image noise was similar in DVT and low-dose CT. As radiation exposure and image noise of DVT is similar to low-dose CT, this imaging technique cannot be recommended as a general alternative to replace PR in dental radiology. (orig.)

  14. A quantum criticality perspective on the charging of narrow quantum-dot levels

    OpenAIRE

    Kashcheyevs, V.; Karrasch, C.; Hecht, T.; Weichselbaum, A.; Meden, V.; Schiller, A.

    2008-01-01

    Understanding the charging of exceptionally narrow levels in quantum dots in the presence of interactions remains a challenge within mesoscopic physics. We address this fundamental question in the generic model of a narrow level capacitively coupled to a broad one. Using bosonization we show that for arbitrary capacitive coupling charging can be described by an analogy to the magnetization in the anisotropic Kondo model, featuring a low-energy crossover scale that depends in a power-law fashi...

  15. Modeling on bubbly to churn flow pattern transition in narrow rectangular channel

    International Nuclear Information System (INIS)

    Wang Yanlin; Chen Bingde; Huang Yanping; Wang Junfeng

    2012-01-01

    A theoretical model based on some reasonable concepts was developed to predict the bubbly flow to churn flow pattern transition in vertical narrow rectangular channel under flow boiling condition. The maximum size of ideal bubble in narrow rectangular channel was calculated based on previous literature. The thermal hydraulics boundary condition of bubbly to churn flow pattern transition was exported from Helmholtz and maximum size of ideal bubble. The theoretical model was validated by existent experimental data. (authors)

  16. Tablet splitting of narrow therapeutic index drugs: a nationwide survey in Taiwan.

    Science.gov (United States)

    Chou, Chia-Lin; Hsu, Chia-Chen; Chou, Chia-Yu; Chen, Tzeng-Ji; Chou, Li-Fang; Chou, Yueh-Ching

    2015-12-01

    Tablet splitting or pill splitting frequently occurs in daily medical practice. For drugs with special pharmacokinetic characters, such as drugs with narrow therapeutic index (NTI), unequal split tablets might lead to erroneous dose titration and it even cause toxicity. The aim of this study was to investigate the frequency of prescribing split NTI drugs at ambulatory setting in Taiwan. A population-based retrospective study was conducted using the National Health Insurance Research Database in Taiwan. All ambulatory visits were analyzed from the longitudinal cohort datasets of the National Health Insurance Research Database. The details of ambulatory prescriptions containing NTI drugs were extracted by using the claims datasets of one million beneficiaries from National Healthcare Insurance Research Database in 2010 in Taiwan. The analyses were stratified by dosage form, patient age and the number of prescribed tablets in a single dose for each NTI drugs. Main outcome measures Number and distinct dosage forms of available NTI drug items in Taiwan, number of prescriptions involved split NTI drugs, and number of patients received split NTI drugs. A total of 148,548 patients had received 512,398 prescriptions of NTI drugs and 41.8 % (n = 62,121) of patients had received 36.3 % (n = 185,936) of NTI drug prescriptions in form of split tablets. The percentage of splitting was highest in digoxin prescriptions (81.0 %), followed by warfarin (72.0 %). In the elderly patients, split tablets were very prevalent with digoxin (82.4 %) and warfarin (84.5 %). NTI drugs were frequently prescribed to be taken in split forms in Taiwan. Interventions may be needed to provide effective and convenient NTI drug use. Further studies are needed to evaluate the clinical outcome of inappropriate split NTI drugs.

  17. Radiation protection clothing in X-ray diagnostics. Comparison of attenuation equivalents in narrow beam and inverse broad-beam geometry

    International Nuclear Information System (INIS)

    Pichler, Thomas; Schoepf, T.; Ennemoser, O.

    2011-01-01

    Purpose: Standard DIN EN 61 331-1 for attenuation measurements in the narrow and broad beam as well as DIN 6857-1 for the determination of shielding properties in the inverse broad-beam geometry are available for testing the attenuation of protection clothing. The attenuation measurements in the narrow beam don't consider scattered radiation and fluorescence due to the arrangement. This leads to the fact that the protective effect of lead-free materials will be misestimated when compared to lead. Therefore, the differences in attenuation equivalents, determined by both test methods for topical radiation protection aprons, were examined. Materials and Methods: The attenuations in inverse broad-beam geometry according to DIN 6857-1 and in the narrow beam according to DIN EN 61 331-1 were measured using commercially available aprons. They were made of lead, lead-reduced and lead-free materials. For determination of the attenuation equivalents, certificated lead-foils with high purity and a precise thickness of 0.1 to 1.25 mm were used. Results: The measurements in the narrow beam according to DIN EN 61 331-1 showed that nearly all aprons reach the required lead equivalent at mid-range tube voltages of 100 kV. At higher and lower tube voltages, the requirements of DIN EN 61 331-3 were largely not met. In contrast, the testing of the same aprons in inverse broad-beam geometry according to DIN 6857-1 showed that only a few aprons meet the requirements for being classified in the nominal protection class. Conclusion: The measurements suggest that testing method DIN 6857-1 has yet to prevail and that manufacturers are just beginning to develop the appropriate protective materials. (orig.)

  18. Dose-response relationship of γ-ray-induced reciprocal translocations at low doses in spermatogonia of the crab-eating monkey (Macaca fascicularis)

    International Nuclear Information System (INIS)

    Matsuda, Yoichi; Tobari, Izuo; Yamagiwa, Junji; Utsugi, Toyoko; Okamoto, Masanori; Nakai, Sayaka

    1985-01-01

    The yield of translocations induced by acute γ-irradiation at low doses in the crab-eating monkey's (Macaca fascicularis) spermatogonia was examined. Over the low dose range from 0 to 1 Gy, the dose-response relationship for translocation yield was a linear one. To estimate the sensitivity to the induction of translocations in the crab-eating monkey's spermatogonia, the slope of the regression line was compared with those in other mammalian species. Consequently, over the low dose range below 1 Gy, the sensitivity of the crab-eating monkey's spermatogonia to translocation induction was similar to several mammalian species, the mouse, Chinese hamster, and the rabbit, but significantly higher than that of the rhesus monkey and lower than that of the marmoset. (Auth.)

  19. Self-seeding scheme with gas monochromator for narrow-bandwidth soft X-ray FELs

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-03-15

    Self-seeding schemes, consisting of two undulators with a monochromator in between, aim at reducing the bandwidth of SASE X-ray FELs. We recently proposed to use a new method of monochromatization exploiting a single crystal in Bragg transmission geometry for self-seeding in the hard X-ray range. Here we consider a possible extension of this method to the soft X-ray range using a cell filled with resonantly absorbing gas as monochromator. The transmittance spectrum in the gas exhibits an absorbing resonance with narrow bandwidth. Then, similarly to the hard X-ray case, the temporal waveform of the transmitted radiation pulse is characterized by a long monochromatic wake. In fact, the FEL pulse forces the gas atoms to oscillate in a way consistent with a forward-propagating, monochromatic radiation beam. The radiation power within this wake is much larger than the equivalent shot noise power in the electron bunch. Further on, the monochromatic wake of the radiation pulse is combined with the delayed electron bunch and amplified in the second undulator. The proposed setup is extremely simple, and composed of as few as two simple elements. These are the gas cell, to be filled with noble gas, and a short magnetic chicane. The installation of the magnetic chicane does not perturb the undulator focusing system and does not interfere with the baseline mode of operation. In this paper we assess the features of gas monochromator based on the use of He and Ne.We analyze the processes in the monochromator gas cell and outside it, touching upon the performance of the differential pumping system as well. We study the feasibility of using the proposed self-seeding technique to generate narrow bandwidth soft X-ray radiation in the LCLS-II soft X-ray beam line. We present conceptual design, technical implementation and expected performances of the gas monochromator self-seeding scheme. (orig.)

  20. Self-seeding scheme with gas monochromator for narrow-bandwidth soft X-ray FELs

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2011-03-01

    Self-seeding schemes, consisting of two undulators with a monochromator in between, aim at reducing the bandwidth of SASE X-ray FELs. We recently proposed to use a new method of monochromatization exploiting a single crystal in Bragg transmission geometry for self-seeding in the hard X-ray range. Here we consider a possible extension of this method to the soft X-ray range using a cell filled with resonantly absorbing gas as monochromator. The transmittance spectrum in the gas exhibits an absorbing resonance with narrow bandwidth. Then, similarly to the hard X-ray case, the temporal waveform of the transmitted radiation pulse is characterized by a long monochromatic wake. In fact, the FEL pulse forces the gas atoms to oscillate in a way consistent with a forward-propagating, monochromatic radiation beam. The radiation power within this wake is much larger than the equivalent shot noise power in the electron bunch. Further on, the monochromatic wake of the radiation pulse is combined with the delayed electron bunch and amplified in the second undulator. The proposed setup is extremely simple, and composed of as few as two simple elements. These are the gas cell, to be filled with noble gas, and a short magnetic chicane. The installation of the magnetic chicane does not perturb the undulator focusing system and does not interfere with the baseline mode of operation. In this paper we assess the features of gas monochromator based on the use of He and Ne.We analyze the processes in the monochromator gas cell and outside it, touching upon the performance of the differential pumping system as well. We study the feasibility of using the proposed self-seeding technique to generate narrow bandwidth soft X-ray radiation in the LCLS-II soft X-ray beam line. We present conceptual design, technical implementation and expected performances of the gas monochromator self-seeding scheme. (orig.)

  1. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  2. Supplementary comparison CCRI(I)-S2 of standards for absorbed dose to water in 60Co gamma radiation at radiation processing dose levels

    DEFF Research Database (Denmark)

    Burns, D. T.; Allisy-Roberts, P. J.; Desrosiers, M. F.

    2011-01-01

    Eight national standards for absorbed dose to water in 60Co gamma radiation at the dose levels used in radiation processing have been compared over the range from 1 kGy to 30 kGy using the alanine dosimeters of the NIST and the NPL as the transfer dosimeters. The comparison was organized...... by the Bureau International des Poids et Mesures, who also participated at the lowest dose level using their radiotherapy-level standard for the same quantity. The national standards are in general agreement within the standard uncertainties, which are in the range from 1 to 2 parts in 102. Evidence of a dose...

  3. A PC program for estimating organ dose and effective dose values in computed tomography

    International Nuclear Information System (INIS)

    Kalender, W.A.; Schmidt, B.; Schmidt, M.; Zankl, M.

    1999-01-01

    Dose values in CT are specified by the manufacturers for all CT systems and operating conditions in phantoms. It is not trivial, however, to derive dose values in patients from this information. Therefore, we have developed a PC-based program which calculates organ dose and effective dose values for arbitrary scan parameters and anatomical ranges. Values for primary radiation are derived from measurements or manufacturer specifications; values for scattered radiation are derived from Monte Carlo calculations tabulated for standard anthropomorphic phantoms. Based on these values, organ doses can be computed by the program for arbitrary scan protocols in conventional and in spiral CT. Effective dose values are also provided, both with ICRP 26 and ICRP 60 tissue-weighting coefficients. Results for several standard CT protocols are presented in tabular form in this paper. In addition, potential for dose reduction is demonstrated, for example, in spiral CT and in quantitative CT. Providing realistic patient dose estimates for arbitrary CT protocols is relevant both for the physician and the patient, and it is particularly useful for educational and training purposes. The program, called WinDose, is now in use at the Erlangen University hospitals (Germany) as an information tool for radiologists and patients. Further extensions are planned. (orig.)

  4. Realization of 3D evaluation algorithm in dose-guided radiotherapy

    International Nuclear Information System (INIS)

    Wang Yu; Li Gui; Wang Dong; Wu Yican; FDS Team

    2012-01-01

    3D evaluation algorithm instead of 2D evaluation method of clinical dose verification is highly needed for dose evaluation in Dose-guided Radiotherapy. 3D evaluation algorithm of three evaluation methods, including Dose Difference, Distance-To-Agreement and 7 Analysis, was realized by the tool of Visual C++ according to the formula. Two plans were designed to test the algorithm, plan 1 was radiation on equivalent water using square field for the verification of the algorithm's correctness; plan 2 was radiation on the emulation head phantom using conformal field for the verification of the algorithm's practicality. For plan 1, the dose difference, in the tolerance range has a pass rate of 100%, the Distance-To-Agreement and 7 analysis was of a pass rate of 100% in the tolerance range, and a pass rate of 99±1% at the boundary of range. For plan 2, the pass rate of algorithm were 88.35%, 100%, 95.07% for the three evaluation methods, respectively. It can be concluded that the 3D evaluation algorithm is feasible and could be used to evaluate 3D dose distributions in Dose-guided Radiotherapy. (authors)

  5. Frontal Plane Modelling of Human Dynamics during Standing in Narrow-Stance

    Science.gov (United States)

    Sonobe, M.; Yamaguchi, H.; Hino, J.

    2016-09-01

    Standing ride type vehicles like electric skateboards have been developed in recent years. Although these vehicles have advantages as being compact and low cost due to their simple structure, it is necessary to improve the riding quality. Therefore, the system aiding riders to keep their balance on a skateboard by feedback control or feedforward control has been required. To achieve it, a human balance model should be built as simple as possible. In this study, we focus on the human balance modelling during standing when the support surface moves largely. We restricted the model on frontal plane and narrow stance because the restrictions allow us to assume single-degree-of-freedom model. The balance control system is generally assumed as a delayed feedback control system. The model was identified through impulse response test and frequency response test. As a result, we found the phase between acceleration of the skateboard and posture angle become opposite phase in low frequency range.

  6. A narrow linewidth tunable single longitudinal mode Ga-EDF fiber laser

    Science.gov (United States)

    Mohamed Halip, N. H.; Abu Bakar, M. H.; Latif, A. A.; Muhd-Yasin, S. Z.; Zulkifli, M. I.; Mat-Sharif, K. A.; Omar, N. Y. M.; Mansoor, A.; Abdul-Rashid, H. A.; Mahdi, M. A.

    2018-05-01

    A tunable ring cavity single longitudinal mode (SLM) fiber laser incorporating Gallium-Erbium co-doped fiber (Ga-EDF) gain medium and several mode filtration techniques is demonstrated. With Ga-EDF, high emission power was accorded in short fiber length, allowing shorter overall cavity length and wider free spectral range. Tunable bandpass filter, sub-ring structure, and cascaded dissimilar fiber taper were utilized to filter multi-longitudinal modes. Each of the filter mechanism was tested individually within the laser cavity to assess its performance. Once the performance of each filter was obtained, all of them were deployed into the laser system. Ultimately, the 1561.47 nm SLM laser achieved a narrow linewidth laser, optical signal-to-noise ratio, and power fluctuation of 1.19 kHz, 61.52 dB and 0.16 dB, respectively. This work validates the feasibility of Ga-EDF to attain a stable SLM output in simple laser configuration.

  7. Comparison of radiation doses using weight-based protocol and dose modulation techniques for patients undergoing biphasic abdominal computed tomography examinations

    Directory of Open Access Journals (Sweden)

    Livingstone Roshan

    2009-01-01

    Full Text Available Computed tomography (CT of the abdomen contributes a substantial amount of man-made radiation dose to patients and use of this modality is on the increase. This study intends to compare radiation dose and image quality using dose modulation techniques and weight- based protocol exposure parameters for biphasic abdominal CT. Using a six-slice CT scanner, a prospective study of 426 patients who underwent abdominal CT examinations was performed. Constant tube potentials of 90 kV and 120 kV were used for all arterial and portal venous phase respectively. The tube current-time product for weight-based protocol was optimized according to patient′s body weight; this was automatically selected in dose modulations. The effective dose using weight-based protocol, angular and z-axis dose modulation was 11.3 mSv, 9.5 mSv and 8.2 mSv respectively for the patient′s body weight ranging from 40 to 60 kg. For patients of body weights ranging 60 to 80 kg, the effective doses were 13.2 mSv, 11.2 mSv and 10.6 mSv respectively. The use of dose modulation technique resulted in a reduction of 16 to 28% in radiation dose with acceptable diagnostic accuracy in comparison to the use of weight-based protocol settings.

  8. Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus

    International Nuclear Information System (INIS)

    Zhang, Yakun; Li, Xiang; Segars, W. Paul; Samei, Ehsan

    2014-01-01

    Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definium 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDI vol and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics

  9. Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yakun [Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Li, Xiang [Medical Physics Graduate Program, Department of Physics, Cleveland State University, Cleveland, Ohio 44115 (United States); Segars, W. Paul [Medical Physics Graduate Program, Carl E. Ravin Advanced Imaging Laboratories, and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Samei, Ehsan, E-mail: samei@duke.edu [Medical Physics Graduate Program, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Departments of Physics, Biomedical Engineering, and Electrical and Computer Engineering, Duke University Medical Center, Durham, North Carolina 27705 (United States)

    2014-02-15

    Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definium 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDI{sub vol} and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose

  10. Droplet squeezing through a narrow constriction: Minimum impulse and critical velocity

    Science.gov (United States)

    Zhang, Zhifeng; Drapaca, Corina; Chen, Xiaolin; Xu, Jie

    2017-07-01

    Models of a droplet passing through narrow constrictions have wide applications in science and engineering. In this paper, we report our findings on the minimum impulse (momentum change) of pushing a droplet through a narrow circular constriction. The existence of this minimum impulse is mathematically derived and numerically verified. The minimum impulse happens at a critical velocity when the time-averaged Young-Laplace pressure balances the total minor pressure loss in the constriction. Finally, numerical simulations are conducted to verify these concepts. These results could be relevant to problems of energy optimization and studies of chemical and biomedical systems.

  11. Nuclear Enterprises portable dose rate meter type PDR 2

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    This instrument is a portable battery powered dose rate meter covering the dose rate range from 0.05 to 500 mrad h -1 . It is designed to measure X- and γ-radiation dose rates over the energy range from 35 keV to 3 MeV. The radiation detector is an MX 164/S GM tube provided with a compensation sheath. The report describes the instrument under the headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; the manual; summary of performance. (U.K.)

  12. The profound effects of patient arm positioning on organ doses from CT procedures calculated using Monte Carlo simulations and deformable phantoms

    International Nuclear Information System (INIS)

    Liu, Haikuan; Gao, Yiming; Ding, Aiping; Caracappa, Peter F.; George Xu, X.

    2015-01-01

    current necessary to overcome the presence of the arms while maintaining sufficient image quality Arm position affects the dose to internal organs from CT scans by as much as 25.3 %. The presence of arms in the scan range results in a dose increase for the skin and bone surface, but a dose decrease for organs located in the torso. Considering the use of TCM, which is common in many clinics, the patient having lowered arms may receive 50 % higher radiation dose to most of the organs because of the increased tube current. The use of higher tube voltage might narrow such dose differences between patients of these two postures due to the greater penetration of higher-energy X rays. Therefore, when calculating or reporting patient doses from CT scans, it is prudent to select an appropriate phantom that accurately represents the patient posture. (authors)

  13. The mean-size dependence of the exchange narrowing in molecular J-aggregates

    International Nuclear Information System (INIS)

    Chen Yulu; Zhao Jijun

    2011-01-01

    The effect of segment-size fluctuations on exchange narrowing in a molecular J-aggregate of site-energy disordered distributions is studied using a one-dimensional Frenkel-exciton model. It is found that the segment-size disorder leads to the width of the absorption spectra deviating from the scaling law, σ 4/3 of the site-energy disordered standard deviation σ, being suitable for the system only with the site-energy disorder. In larger σ, the segment-size disorder has little influence on the linear absorption spectra. With increasing segment mean-length, the absorption line width monotonically increases, and then approaches a saturated value. By comparing a system of larger mean-length segment with a smaller one, both with the same segment-size disorder, it is found that the absorption line width of the former is broadened, and the exchange narrowing effect is reduced. The present result shows that the correlation effect can be partially maintained for the system with larger mean-length segment. -- Research Highlights: → Segment fluctuations affect the exchange narrowing of molecular J-aggregates. → The width of the absorption spectra is found to deviate from the scaling law. → Increase in segment size causes increase in the width and then saturates. → Exchange narrowing is reduced for larger mean-size segment. → Correlation can be kept partly in the larger size segment.

  14. Dosimetry investigation of MOSFET for clinical IMRT dose verification.

    Science.gov (United States)

    Deshpande, Sudesh; Kumar, Rajesh; Ghadi, Yogesh; Neharu, R M; Kannan, V

    2013-06-01

    In IMRT, patient-specific dose verification is followed regularly at each centre. Simple and efficient dosimetry techniques play a very important role in routine clinical dosimetry QA. The MOSFET dosimeter offers several advantages over the conventional dosimeters such as its small detector size, immediate readout, immediate reuse, multiple point dose measurements. To use the MOSFET as routine clinical dosimetry system for pre-treatment dose verification in IMRT, a comprehensive set of experiments has been conducted, to investigate its linearity, reproducibility, dose rate effect and angular dependence for 6 MV x-ray beam. The MOSFETs shows a linear response with linearity coefficient of 0.992 for a dose range of 35 cGy to 427 cGy. The reproducibility of the MOSFET was measured by irradiating the MOSFET for ten consecutive irradiations in the dose range of 35 cGy to 427 cGy. The measured reproducibility of MOSFET was found to be within 4% up to 70 cGy and within 1.4% above 70 cGy. The dose rate effect on the MOSFET was investigated in the dose rate range 100 MU/min to 600 MU/min. The response of the MOSFET varies from -1.7% to 2.1%. The angular responses of the MOSFETs were measured at 10 degrees intervals from 90 to 270 degrees in an anticlockwise direction and normalized at gantry angle zero and it was found to be in the range of 0.98 ± 0.014 to 1.01 ± 0.014. The MOSFETs were calibrated in a phantom which was later used for IMRT verification. The measured calibration coefficients were found to be 1 mV/cGy and 2.995 mV/cGy in standard and high sensitivity mode respectively. The MOSFETs were used for pre-treatment dose verification in IMRT. Nine dosimeters were used for each patient to measure the dose in different plane. The average variation between calculated and measured dose at any location was within 3%. Dose verification using MOSFET and IMRT phantom was found to quick and efficient and well suited for a busy radiotherapy

  15. The dependence of radiation response on the dose per fraction

    International Nuclear Information System (INIS)

    Joiner, M.C.

    1989-01-01

    The linear-quadratic (LQ) model explains the dependence of total dose in a fractionated course on the dose per fraction, in a very wide range of tumour and normal tissue studies, providing the dose per fraction remains above 2 Gy. In the range 2-1 Gy per fraction, some experimental studies show less increase in total dose than predicted by LQ; a probable explanation is incomplete repair between fractions given 2 seen between 1 and 0.1 Gy per fraction. This cannot be explained by incomplete repair; a modified LQ model where α decreases sharply with increasing dose per fraction in the range 0-1 Gy fits these data. The basic LQ model describes data from neutron fractionation studies, so the relationship between relative biological effectiveness (RBE) and X-ray dose per fraction can be expressed in terms of LQ parameters and fitted directly to RBE data. Results from different experiments, different assays and both top-up and full-course fractionation techniques, can all be included in one analysis. (author)

  16. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  17. Kinetic and dose dependencies of the SOS-induction in E.coli K-12 (uvrA) cells exposed to different UV doses

    International Nuclear Information System (INIS)

    Komova, O.V.; Kandiano, E.S.; Malavina, G.; )

    2000-01-01

    Kinetic and dose dependencies of the SOS-induction in E. coli (uvrA) cells exposed to UV light were investigated. below 2 J/m 2 the rate of the SOS-induction increased with dose. Maximal level of the SOS-response was proportional to the UV dose. Pyrimidine dimers were necessary for the induction. In the dose range 2-10 J/m 2 the rate of SOS-induction decreased with dose. Dose-maximum response curve was non-linear. Pyrimidine dimers were not required for the induction. nature of the molecular events leading to the SOS-induction at low and high doses was discussed [ru

  18. Microsputterer with integrated ion-drag focusing for additive manufacturing of thin, narrow conductive lines

    Science.gov (United States)

    Kornbluth, Y. S.; Mathews, R. H.; Parameswaran, L.; Racz, L. M.; Velásquez-García, L. F.

    2018-04-01

    We report the design, modelling, and proof-of-concept demonstration of a continuously fed, atmospheric-pressure microplasma metal sputterer that is capable of printing conductive lines narrower than the width of the target without the need for post-processing or lithographic patterning. Ion drag-induced focusing is harnessed to print narrow lines; the focusing mechanism is modelled via COMSOL Multiphysics simulations and validated with experiments. A microplasma sputter head with gold target is constructed and used to deposit imprints with minimum feature sizes as narrow as 9 µm, roughness as small as 55 nm, and electrical resistivity as low as 1.1 µΩ · m.

  19. Motion-induced dose artifacts in helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bryan; Chen, Jeff; Battista, Jerry [London Regional Cancer Program, London Health Sciences Centre, London, ON (Canada); Kron, Tomas [Peter MacCallum Cancer Center, Melbourne (Australia)], E-mail: bryan.kim@lhsc.on.ca

    2009-10-07

    Tumor motion is a particular concern for a complex treatment modality such as helical tomotherapy, where couch position, gantry rotation and MLC leaf opening all change with time. In the present study, we have investigated the impact of tumor motion for helical tomotherapy, which could result in three distinct motion-induced dose artifacts, namely (1) dose rounding, (2) dose rippling and (3) IMRT leaf opening asynchronization effect. Dose rounding and dose rippling effects have been previously described, while the IMRT leaf opening asynchronization effect is a newly discovered motion-induced dose artifact. Dose rounding is the penumbral widening of a delivered dose distribution near the edges of a target volume along the direction of tumor motion. Dose rippling is a series of periodic dose peaks and valleys observed within the target region along the direction of couch motion, due to an asynchronous interplay between the couch motion and the longitudinal component of tumor motion. The IMRT leaf opening asynchronization effect is caused by an asynchronous interplay between the temporal patterns of leaf openings and tumor motion. The characteristics of each dose artifact were investigated individually as functions of target motion amplitude and period for both non-IMRT and IMRT helical tomotherapy cases, through computer simulation modeling and experimental verification. The longitudinal dose profiles generated by the simulation program agreed with the experimental data within {+-}0.5% and {+-}1.5% inside the PTV region for the non-IMRT and IMRT cases, respectively. The dose rounding effect produced a penumbral increase up to 20.5 mm for peak-to-peak target motion amplitudes ranging from 1.0 cm to 5.0 cm. Maximum dose rippling magnitude of 25% was calculated, when the target motion period approached an unusually high value of 10 s. The IMRT leaf opening asynchronization effect produced dose differences ranging from -29% to 7% inside the PTV region. This information

  20. Optically trapped atomic resonant devices for narrow linewidth spectral imaging

    Science.gov (United States)

    Qian, Lipeng

    This thesis focuses on the development of atomic resonant devices for spectroscopic applications. The primary emphasis is on the imaging properties of optically thick atomic resonant fluorescent filters and their applications. In addition, this thesis presents a new concept for producing very narrow linewidth light as from an atomic vapor lamp pumped by a nanosecond pulse system. This research was motivated by application for missile warning system, and presents an innovative approach to a wide angle, ultra narrow linewidth imaging filter using a potassium vapor cell. The approach is to image onto and collect the fluorescent photons emitted from the surface of an optically thick potassium vapor cell, generating a 2 GHz pass-band imaging filter. This linewidth is narrow enough to fall within a Fraunhefer dark zone in the solar spectrum, thus make the detection solar blind. Experiments are conducted to measure the absorption line shape of the potassium resonant filter, the quantum efficiency of the fluorescent behavior, and the resolution of the fluorescent image. Fluorescent images with different spatial frequency components are analyzed by using a discrete Fourier transform, and the imaging capability of the fluorescent filter is described by its Modulation Transfer Function. For the detection of radiation that is spectrally broader than the linewidth of the potassium imaging filter, the fluorescent image is seen to be blurred by diffuse fluorescence from the slightly off resonant photons. To correct this, an ultra-thin potassium imaging filter is developed and characterized. The imaging property of the ultra-thin potassium imaging cell is tested with a potassium seeded flame, yielding a resolution image of ˜ 20 lines per mm. The physics behind the atomic resonant fluorescent filter is radiation trapping. The diffusion process of the resonant photons trapped in the atomic vapor is theoretically described in this thesis. A Monte Carlo method is used to simulate the