WorldWideScience

Sample records for narrow diameter implants

  1. Clinical outcome of narrow diameter implants inserted into allografts

    Directory of Open Access Journals (Sweden)

    Maurizio Franco

    2009-08-01

    Full Text Available OBJECTIVE: Narrow diameter implants (NDI (i.e. diameter <3.75 mm are a potential solution for specific clinical situations, such as reduced interradicular bone, thin alveolar crest and replacement of teeth with small cervical diameter. NDI have been available in clinical practice since the 1990s, but only few studies have analyzed their clinical outcome and no study have investigated NDI inserted in fresh-frozen bone (FFB grafts. Thus, a retrospective study on a series of NDI placed in homologue FFB was designed to evaluate their clinical outcome. MATERIAL AND METHODS: In the period between December 2003 and December 2006, 36 patients (22 females and 14 males, mean age 53 years with FFB grafts were selected and 94 different NDI were inserted. The mean follow-up was 25 months. To evaluate the effect of several host-, surgery-, and implant-related factors, marginal bone loss (MBL was considered an indicator of success rate (SCR. The Kaplan Meier algorithm and Cox regression were used. RESULTS: Only 5 out of 94 implants were lost (i.e. survival rate - SVR 95.7% and no differences were detected among the studied variables. On the contrary, the Cox regression showed that the graft site (i.e. maxilla reduced MBL. CONCLUSIONS: NDI inserted in FFB have a high SVR and SCR similar to those reported in previous studies on regular and NDI inserted in non-grafted jaws. Homologue FFB is a valuable material in the insertion of NDI.

  2. Application of a narrow-diameter implant in a limited space

    Directory of Open Access Journals (Sweden)

    Chia-Yun Tsai

    2010-06-01

    Full Text Available This report presents a case of inadequate space distribution after orthodontic treatment, when a narrow-diameter implant was placed in a limited mandibular anterior space (ridge and prosthetic. A 26-year-old female patient presented with a purulent discharge from the mandibular right posterior area. Radiographic and clinical evaluations revealed a four-unit bridge spanning teeth 42 to 43 and acute apical periodontitis with root resorption around tooth 42. After careful evaluation, tooth 42 was extracted, and orthodontic treatment was performed to align the posterior teeth and create a dimensionally appropriate space between teeth 41 and 43. A 3i MicroMiniplant with dimensions of 3.25 mm (diameter × 11.5 mm was implanted in the edentulous area of tooth 42 because of the small size of tooth 42. Autogenous bone particles were placed on the buccal crestal defect, and a healing abutment was attached. After an 8-month healing phase, a final impression was made and an all-ceramic crown was delivered. This case demonstrates that osseous sites with significant dimensional space limitations can be successfully utilized to receive and integrate a narrow-diameter implant that will satisfy esthetic, phonetic and functional requirements.

  3. Two Versus Three Narrow-Diameter Implants with Locator Attachments Supporting Mandibular Overdentures: A Two-Year Prospective Study

    Directory of Open Access Journals (Sweden)

    Ali M. El-Sheikh

    2012-01-01

    Full Text Available Purpose. To compare treatment outcome (survival rate, condition of hard and soft peri-implant tissues and prosthodontic maintenance requirements of two versus three narrow-diameter bone level implants with Locator attachments supporting mandibular overdentures. Materials and Methods. Twenty completely edentulous patients with atrophic mandibles were treated. Ten patients (Group A were treated with overdentures supported by two narrow (3.3-mm diameter implants (Straumann AG, Basel, Switzerland and ten patients (Group B were treated with overdentures supported by three narrow implants. Locator (Zest Anchors, USA attachments were used for prosthetic anchorage. Standardized clinical and radiographic parameters (survival rate, plaque index, calculus index, gingival index, bleeding index, probing depth and marginal bone loss were evaluated at the time of the completion of the prosthetic treatment (baseline and after 6, 12 and 24 months of functional loading. Prosthodontic maintenance requirements were also scored. Results. Only one implant was lost (Group B during the healing period. There were no significant differences with regards to any of the studied clinical and radiographic parameters between the two groups (>0.05. Few prosthetic complications were recorded. Conclusions. No need to insert more than two narrow-diameter bone level implants with Locator attachments in cases of atrophic mandible to support an overdenture, however, long-term prospective studies are required to support this notion.

  4. Clinical and radiographic evaluation of early loaded narrow-diameter implants

    DEFF Research Database (Denmark)

    Maiorana, Carlo; King, Paul; Quaas, Sebastian

    2015-01-01

    OBJECTIVE: To evaluate the clinical reliability of narrow implants placed in a one-stage procedure and early loaded in the upper and lower incisor region. MATERIAL AND METHODS: This is a prospective, single-arm, multicenter study in which patients with missing natural dentition in upper lateral a...... be considered as a valid solution in the treatment of the localized narrow bony defects in the anterior area with reduced spaces between the natural teeth....... healing period. Clinical and radiographic checks were performed at implant placement, loading, and at the 6, 12, 24, and 36 months follow-up visits. RESULTS: A total of 69 subjects with 97 implants have been included in this study. From surgery to 36 months follow-up, 5.6% of the implants showed bone loss...... loss between loading and the 1-year follow-up visit (Galindo-Moreno et al. 2012). This finding, associated with a stable probing pocket depth and a stable crown-gingiva distance, using a one-stage surgical procedure helps to maintain the integrity of the peri-implant soft tissues. Narrow implants can...

  5. Effect of microthreads on coronal bone healing of narrow-diameter implants with reverse-tapered design in beagle dogs.

    Science.gov (United States)

    Chang, Yun-Young; Kim, Su-Hwan; Park, Keun-Oh; Yun, Jeong-Ho

    2017-12-01

    The objective of this study was to investigate the effect of microthreads on the coronal bone healing of narrow-diameter implants with reverse-tapered design. A total of 52 implants were classified into two groups according to presence or absence of coronal microthreads, the reverse-tapered narrow-diameter implant (RTN) group, and the reverse-tapered narrow-diameter implant with microthreads (RTNM) group. The implants were installed in split-mouth design in the edentulous mandible of six dogs. Three animals were sacrificed at 4 weeks and three at 8 weeks. Resonance frequency analysis, bone measurement using microcomputed tomography (micro-CT), removal torque test, and histometric analysis were performed. No significant differences in implant stability quotient value were observed between the groups at baseline, 4 weeks, or 8 weeks. Bone measurement using micro-CT showed that bone-implant contact volume (BICV) and bone-implant contact volume ratio (BICVR) in the coronal part of RTNM were statistically higher than those in RTN at 4 and 8 weeks. Histometric analysis showed statistically higher bone-implant contact length (BICL) in the coronal part of RTNM than in RTN at 4 weeks; however, bone-implant contact ratio (BICR) was not significantly different between the groups. At 8 weeks, the BICL and BICR did not differ significantly between the groups. Removal torque test showed no significant differences between the groups at 4 and 8 weeks. The microthreads might facilitate more coronal bone-implant contact due to increased surface areas at an early healing phase; however, they did not significantly affect coronal bone healing at 8 weeks. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: A study on the titanium resin base concept.

    Science.gov (United States)

    Sailer, Irena; Asgeirsson, Asgeir G; Thoma, Daniel S; Fehmer, Vincent; Aspelund, Thor; Özcan, Mutlu; Pjetursson, Bjarni E

    2018-04-01

    There is limited knowledge regarding the strength of zirconia abutments with internal and external implant abutment connections and zirconia abutments supported by a titanium resin base (Variobase, Straumann) for narrow diameter implants. To compare the fracture strength of narrow diameter abutments with different types of implant abutment connections after chewing simulation. Hundred and twenty identical customized abutments with different materials and implant abutment connections were fabricated for five groups: 1-piece zirconia abutment with internal connection (T1, Cares-abutment-Straumann BL-NC implant, Straumann Switzerland), 1-piece zirconia abutment with external hex connection (T2, Procera abutment-Branemark NP implant, Nobel Biocare, Sweden), 2-piece zirconia abutments with metallic insert for internal connection (T3, Procera abutment-Replace NP implant, Nobel Biocare), 2-piece zirconia abutment on titanium resin base (T4, LavaPlus abutment-VarioBase-Straumann BL-NC implant, 3M ESPE, Germany) and 1-piece titanium abutment with internal connection (C, Cares-abutment-Straumann BL-NC implant, Straumann, Switzerland). All implants had a narrow diameter ranging from 3.3 to 3.5 mm. Sixty un-restored abutments and 60 abutments restored with glass-ceramic crowns were tested. Mean bending moments were compared using ANOVA with p-values adjusted for multiple comparisons using Tukey's procedure. The mean bending moments were 521 ± 33 Ncm (T4), 404 ± 36 Ncm (C), 311 ± 106 Ncm (T1) 265 ± 22 Ncm (T3) and 225 ± 29 (T2) for un-restored abutments and 278 ± 84 Ncm (T4), 302 ± 170 Ncm (C), 190 ± 55 Ncm (T1) 80 ± 102 Ncm (T3) and 125 ± 57 (T2) for restored abutments. For un-restored abutments, C and T4 had similar mean bending moments, significantly higher than those of the three other groups (p internal connection had higher bending moments than zirconia abutments with external connection (T2) (p internal connected zirconia

  7. Evaluation of 316 narrow diameter implants followed for 5-10 years: a clinical and radiographic retrospective study.

    Science.gov (United States)

    Arisan, Volkan; Bölükbaşi, Nilüfer; Ersanli, Selim; Ozdemir, Tayfun

    2010-03-01

    Narrow diameter implants (NDIs; diameter >3.75 mm) are useful in replacement of missing incisor teeth and when the bucco-lingual width of the edentulous crest is insufficient. The present study evaluated the success and survival rates, peri-implant parameters, mechanical and prosthetic post-loading complications of NDIs followed over a 10-year period. Three hundred and sixteen NDIs were inserted into 139 patients and restored with 120 prostheses. Clinical and radiographic assessment data were collected during recall visits. Implant success (SC), cumulative survival rate (CSR), marginal bone loss (MBL), peri-implant conditions and prosthetic complications were assessed. Cox proportional hazards regression analysis, Kaplan-Meier survival curves with the log-rank test and life table analysis were used to evaluate the outcome of NDIs within comparable subgroups. MBL and peri-implant parameters measured annually were further analyzed. The mean follow-up time was 9.1 years (range: 60-124 months). Twelve implants were lost in the healing phase and two during function. The mean MBL in the maxilla and the mandible was 1.32 +/- 0.13 and 1.28 +/- 0.3 mm, respectively, after 10 years. SC and CSR were 91.4% and 92.3%, respectively, after 124 months. Smoking and posterior localization were associated with an increased risk of failure. Cement loosening (16.8%) was the most common prosthetic complication. No implants were fractured. NDIs can be used with confidence where a regular diameter implant is not suitable. MBL around NDIs occurred predominantly within 2 years of loading and was minimal thereafter. Further studies are required to clarify the possible risks associated with smoking and posterior placement.

  8. Clinical outcome of narrow-diameter (3.3-mm) locking-taper implants: a prospective study with 1 to 10 years of follow-up.

    Science.gov (United States)

    Mangano, Francesco; Shibli, Jamil A; Sammons, Rachel L; Veronesi, Giovanni; Piattelli, Adriano; Mangano, Carlo

    2014-01-01

    To evaluate the outcome of narrow-diameter (3.3-mm) locking-taper implants used in the rehabilitation of partially and fully edentulous patients over a 10-year period. Between January 2002 and December 2011, all patients referred to a private dental clinic for treatment with narrow-diameter implants were enrolled in this study. At each annual follow-up session, clinical and radiographic parameters were assessed; the outcome measurements were implant failure, peri-implant marginal bone loss (distance between the implant shoulder and the first visible bone-to-implant contact [DIB]), and biologic and technical complications. The cumulative survival rate (CSR) was assessed using the Kaplan-Meier survival estimator; Tarone-Ware and chi-square analyses were used to evaluate correlations between the study variables. The statistical analysis was performed at the patient- and implant-level. A total of 324 narrow-diameter implants were placed in 279 patients (159 men, 120 women; age: 25 to 73 years). Four implants failed, for an overall CSR of 98.5% (patient-based) and 98.7% (implant-based) at the 10-year follow-up. The survival rate did not differ significantly with respect to patients' sex, age, smoking or parafunctional habits, bone type, prosthetic restoration, or implant location, position, or length. Among the surviving implants, a mean DIB of 0.31 ± 0.23 mm, 0.45 ± 0.27 mm, and 0.69 ± 0.28 mm was observed at the 1-, 5-, and 10-year follow-up examinations, respectively. A few biologic (1.2%) and technical complications (7.5%) were reported. Within the limitations of this study, it can be concluded that narrow-diameter locking-taper implants represent a good treatment option for the prosthetic rehabilitation of partially and totally edentulous patients.

  9. Retrospective cohort clinical investigation of a dental implant with a narrow diameter and short length for the partial rehabilitation of extremely atrophic jaws.

    Science.gov (United States)

    Maló, Paulo S; de Araújo Nobre, Miguel A; Lopes, Armando V; Ferro, Ana S

    2017-01-01

    We investigated the short-term clinical outcomes of narrow-diameter short-length implants for the fixed-prosthetic partial rehabilitation of extremely resorbed jaws. Twenty-three patients requiring partial rehabilitations with narrow-platform short-length implants in any jaw were included in this study. In total, 30 implants 3.3 mm in diameter and 7 (n = 15 implants) or 8.5 (n = 15 implants) mm in length were inserted. The primary outcome measure was implant cumulative survival rate (CSR); the secondary outcome measures were marginal bone resorption at 1 and 3 years and the incidence of biologic and mechanical complications. Five patients (21.7%) with six implants (20%) were lost to follow-up. Two implants failed in two patients, yielding a CSR at 3 years of follow-up of 93.4%. The average (standard deviation) marginal bone resorption was 1.34 mm (0.95 mm) after the first year and 1.38 mm (0.78 mm) after the third year. Biologic complications occurred in three patients; mechanical complications occurred in three patients. Despite the limitations of the study, our findings show that the use of new narrow-diameter short-length implants for the rehabilitation of extremely atrophic regions is viable in the short-term, and can be considered a treatment alternative in extremely resorbed jaws.

  10. Four-unit fixed dental prostheses replacing the maxillary incisors supported by two narrow-diameter implants - a five-year case series.

    Science.gov (United States)

    Moráguez, Osvaldo; Vailati, Francesca; Grütter, Linda; Sailer, Irena; Belser, Urs C

    2017-07-01

    (1) To determine the survival rate of 10 four-unit fixed dental prostheses (FDPs) replacing the four maxillary incisors, supported by 20 narrow-diameter implants (NDIs), (2) to assess the incidence of mechanical and biological complications, and (3) to evaluate bone level changes longitudinally after final FDP insertion. Ten patients (six women, four men), mean age 49.4 ± 12.6 years, were treated with a four-unit anterior maxillary FDP (six screw-retained; four cemented). Biological parameters, eventual technical complications, radiographic measurements, and study casts were assessed at 1 (baseline), 3, and 5 years after implant placement. A multilevel logistic regression test was performed on clinical parameters and bone level changes (significance level P four-unit FDP to replace the four missing maxillary incisors may be considered a predictable treatment modality. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Chewing efficiency, bite force and oral health-related quality of life with narrow diameter implants - a prospective clinical study: results after one year.

    Science.gov (United States)

    Enkling, Norbert; Saftig, Marcus; Worni, Andreas; Mericske-Stern, Regina; Schimmel, Martin

    2017-04-01

    This prospective study aimed to investigate the evolution of chewing efficiency, maximum voluntary bite force (MBF) and oral health-related quality of life (OHRQoL) in edentulous patients treated with narrow diameter implants (NDIs) over the course of 1 year. Four NDIs (MDI ® , 3M ESPE, diameter 1.8 mm) were placed interforaminally in 20 edentulous patients. They were immediately loaded by converting the existing prosthesis into an implant overdenture. Participants were examined six times pre- and postoperatively [baseline (BL) to week 52 (w52)]. Chewing efficiency was evaluated with a colour-mixing ability test by evaluation of the standard deviation of hue (VOH, ViewGum©). MBF was measured using a digital force gauge. OHRQoL was determined with the Oral Health Impact Profile (OHIPG49). Nonparametric Brunner-Langer models were applied for statistical testing. The study failed to demonstrate an effect on chewing efficiency. MBF increased continuously during the observation period (medians: MBF[N]@BL = 46.6 [iqr 50.1]; MBF[N]@w52 = 103.9 [iqr 76.0]; P = 0.002). OHRQoL increased steeply after implant loading and continued improving (medians: BL ∑OHIPG49 = 31 [iqr 40.0]; w4 ∑OHIPG49 = 11.5 [iqr 19.5]; w52 ∑OHIPG49 = 6 [iqr 13.0], P chewing instructions. Larger studies need to confirm a positive effect on chewing efficiency and develop long-term maintenance solutions if patients become frail because no easy downgrading approaches of one-piece titanium implants exist. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Narrow- (3.0 mm) Versus Standard-Diameter (4.0 and 4.5 mm) Implants for Splinted Partial Fixed Restoration of Posterior Mandibular and Maxillary Jaws: A 5-Year Retrospective Cohort Study.

    Science.gov (United States)

    Pieri, Francesco; Forlivesi, Caterina; Caselli, Ernesto; Corinaldesi, Giuseppe

    2017-04-01

    Evidence concerning predictability of narrow-diameter implants (NDIs) (3.0 mm) and standard-diameter implants (SDIs) (4.0 to 4.5 mm) supporting fixed partial dentures (FPDs) in posterior mandibular and maxillary jaws. All patients treated with at least two adjacent NDIs or SDIs according to available bone thickness and with a minimum follow-up of 5 years after placement were invited to undergo a clinical and radiologic examination. Outcome measures were implant and FPD failures, biologic and prosthetic complications, and marginal bone loss. A total of 107 out of 127 patients attended the examination: 49 (113 implants) of the NDI group, and 58 (126 implants) of the SDI group. Two NDIs failed in one patient versus four SDIs in four patients (P = 0.37). One FPD failed in the NDI group versus two FPDs in the SDI group (P >0.99). Nine biologic complications occurred in the NDI group and twelve in the SDI group (P = 0.81). Twelve prosthetic complications occurred in the NDI group and only two in the SDI group (P = 0.001). Peri-implant marginal bone loss at 5 years was 0.95 ± 0.84 mm for the NDI group and 1.2 ± 0.86 mm for the SDI group (P = 0.06). Five-year data indicate that FPD treatment in posterior mandibular and maxillary jaws with NDIs was as reliable as with SDIs, although NDIs showed a higher risk of prosthetic complications.

  13. Bubble departure diameter in narrow rectangular channel under rolling condition

    Energy Technology Data Exchange (ETDEWEB)

    Xie, T.; Chen, B.; Yan, X.; Xu, J.; Huang, Y.; Xiao, Z. [Nuclear Power Inst. of China, Chengdu, Sichuan (China)

    2014-07-01

    Forced convective subcooled boiling flow experiments were conducted in a vertical upward narrow rectangular channel under rolling motion. A high-speed digital video camera was used to capture the dynamics of the bubble nucleation process. Bubble departure diameters were obtained from the images. A bubble departure model based on force balance analysis was proposed to predict the bubble departure size under rolling condition by considering the additional centrifugal, tangential and Coriolis force. The proposed model agreed well with the experimental data within the averaged relative deviation of 5%. (author)

  14. Effect of bubble interface parameters on predicted of bubble departure diameter in a narrow channel

    International Nuclear Information System (INIS)

    Xu Jianjun; Xie Tianzhou; Zhou Wenbin; Chen Bingde; Huang Yanping

    2014-01-01

    The predicted model on the bubble departure diameter in a narrow channel is built by analysis of forces acting on the bubble, and effects of bubble interface parameters such as the bubble inclination angle, upstream contact angle, downstream contact angle and bubble contact diameter on predicted bubble departure diameters in a narrow channel are analysed by comparing with the visual experimental data. Based on the above results, the bubble interface parameters as the input parameters used to obtain the bubble departure diameter in a narrow channel are assured, and the bubble departure diameters in a narrow channel are predicted by solving the force equation. The predicted bubble departure diameters are verified by the 58 bubble departure diameters obtained from the vertical and inclined visual experiment, and the predicted results agree with the experimental results. The different forces acting on the bubble are obtained and the effect of thermal parameters in this experiment on bubble departure diameters is analysed. (authors)

  15. Fracture strength and probability of survival of narrow and extra-narrow dental implants after fatigue testing: In vitro and in silico analysis.

    Science.gov (United States)

    Bordin, Dimorvan; Bergamo, Edmara T P; Fardin, Vinicius P; Coelho, Paulo G; Bonfante, Estevam A

    2017-07-01

    To assess the probability of survival (reliability) and failure modes of narrow implants with different diameters. For fatigue testing, 42 implants with the same macrogeometry and internal conical connection were divided, according to diameter, as follows: narrow (Ø3.3×10mm) and extra-narrow (Ø2.9×10mm) (21 per group). Identical abutments were torqued to the implants and standardized maxillary incisor crowns were cemented and subjected to step-stress accelerated life testing (SSALT) in water. The use-level probability Weibull curves, and reliability for a mission of 50,000 and 100,000 cycles at 50N, 100, 150 and 180N were calculated. For the finite element analysis (FEA), two virtual models, simulating the samples tested in fatigue, were constructed. Loading at 50N and 100N were applied 30° off-axis at the crown. The von-Mises stress was calculated for implant and abutment. The beta (β) values were: 0.67 for narrow and 1.32 for extra-narrow implants, indicating that failure rates did not increase with fatigue in the former, but more likely were associated with damage accumulation and wear-out failures in the latter. Both groups showed high reliability (up to 97.5%) at 50 and 100N. A decreased reliability was observed for both groups at 150 and 180N (ranging from 0 to 82.3%), but no significant difference was observed between groups. Failure predominantly involved abutment fracture for both groups. FEA at 50N-load, Ø3.3mm showed higher von-Mises stress for abutment (7.75%) and implant (2%) when compared to the Ø2.9mm. There was no significant difference between narrow and extra-narrow implants regarding probability of survival. The failure mode was similar for both groups, restricted to abutment fracture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. The effect of shape, length and diameter of implants on primary stability based on resonance frequency analysis

    Directory of Open Access Journals (Sweden)

    Hamidreza Barikani

    2014-01-01

    Full Text Available Background: The aim of this in vitro study was to evaluate the effect of shape, diameter and length of implants on their primary stability based on resonance frequency analysis. Materials and Methods: Replace select tapered and Branemark MK III implants were selected. Each of these two selected groups was divided into nine subgroups based on the implant length (IL (short, medium and long and the implant diameter (ID (narrow platform [NP], regular platform [RP] and wide platform [WP]. Five implants were assigned to each of the nine subgroups. Implants were placed in artificial bone blocks with bone quality similar to D3 bone. Immediately after the implant placement, its primary stability was measured using Osstell Mentor equipment. T-test and Tukey′s honest significant difference Post hoc were performed for data analysis. Statistical significance was defined at P < 0.05. Results: Replace select system showed significantly higher primary stability compared to the Branemark system, when using the short implants for all three diameters (P ≤ 0.004. However, in medium length implants there were no significant differences between the two implant systems (P ≥ 0.31. In long implants, only when the NP and RP implants were used, the Replace Select system showed significantly higher primary stability compared to the Branemark system (P = 0.000. In the replace select system, long implants had a significantly higher primary stability compared to medium and short length implants (P ≤ 0.003. In the NP and RP Branemark implants, short implants showed significantly lower primary stability compared to medium and long implants (P ≤ 0.002. However, in WP Branemark implants, primary stability increased significantly with increasing the IL from short to medium and from medium to long (P = 0.000. There were also significant differences between NP and the two other wider implants in both systems (P = 0.000. Conclusion: The use of tapered implants is

  17. The success rate of narrow body implants used for supporting immediate provisional restorations: a pilot feasibility study.

    Science.gov (United States)

    Wang, Hom-Lay; Okayasu, Kozue; Fu, Jia-Hui; Hamerink, Howard A; Layher, Mary G; Rudek, Ivan Elimar

    2012-12-01

    Implants were first designed to be used in the reconstruction of edentulous mandibles. However, with the technological advancement, enormous changes were made to improve the implant design and surface characteristics leading to the wide use of implants in the replacement of missing teeth. During the transition from an edentulous span to a fixed prosthesis, narrow body implants (NBIs) have been proposed to enhance patient comfort and function. Therefore, this study was aimed at investigating the survival and success rates of NBIs used for supporting immediately nonfunctional loaded provisional fixed partial denture (PFPD). Either 2.2- or 2.4-mm-diameter dental implants were placed transmucosally into the edentulous ridges of 10 partially edentulous patients. PFPD of self-cured bis-acryl composite material were made using either a vacuform template chairside or a relined prefabricated PFPD. Occlusal adjustments were made to ensure that there was no functional loading on the provisional restorations before they were secured onto the transitional implants. At 1 year, the implant success and survival rates were 38.7% and 93.5%, respectively, with a mean percentage of bone loss of 9.46% (0%-40%) and a mean bone loss of 1.19 mm (range: 0-3.5 mm). With a favorable implant survival rate, the use of NBIs to support provisional restorations seemed to be a feasible treatment option. In addition, there is merit for research on the long-term use of NBIs-supported final prostheses.

  18. Biomechanics and load resistance of small-diameter and mini dental implants: a review of literature.

    Science.gov (United States)

    Hasan, Istabrak; Bourauel, Christoph; Mundt, Torsten; Stark, Helmut; Heinemann, Friedhelm

    2014-02-01

    In recent years, the application of small-diameter and mini dental implants to support removable and fixed prosthesis has dramatically increased. However, the success of these implants under functional biting forces and the reaction of the bone around them need to be analyzed. This review was aimed to present studies that deal with the fatigue life of small-diameter and mini dental implants under normal biting force, and their survival rate. The numerical and experimental studies concluded that an increase in the risk of bone damage or implant failure may be assumed in critical clinical situations and implants with <3 mm diameter have a risk of fracture in clinical practice. The survival rate of the small-diameter and mini dental implants over 5 years was 98.3-99.4%.

  19. Experimental investigation of commercial small diameter dental implants in porcine mandibular segments.

    Science.gov (United States)

    Hasan, Istabrak; Heinemann, Friedhelm; Schwegmann, Monika; Keilig, Ludger; Stark, Helmut; Bourauel, Christoph

    2017-02-01

    Small diameter (mini) dental implants have become more popular in recent years as alternatives to classical implant treatment in clinical cases with critical bony situations. However, an in-depth scientific analysis of the mechanical and biomechanical effects of small diameter implants has not yet been published. The aim of the present study was to investigate experimentally different commercial mini implants by measuring their displacements under immediate loading. Twelve commercially available mini implants were measured. Implants were inserted into porcine mandibular segments and loaded by means of a predefined displacement of 0.5 mm of the loading system. The implants were loaded at an angle of 30° to the implant long axis using the self-developed biomechanical hexapod measurement system. Implant displacements were registered. The experimental results were compared to the numerical ones from a previous study. Measured implant displacements were within the range of 39-194 μm. A large variation in the displacements was obtained among the different implant systems due to the different designs and thread profiles. Comparing experimental and numerical results, the displacements that were obtained numerically were within the range of 79-347 μm. The different commercial mini implants showed acceptable primary stability and could be loaded immediately after their insertion.

  20. Influence of simulated bone-implant contact and implant diameter on secondary stability: a resonance frequency in vitro study.

    Science.gov (United States)

    Veltri, Mario; González-Martín, Oscar; Belser, Urs C

    2014-08-01

    This study tested the hypothesis of no differences in resonance frequency for standardized amounts of simulated bone-implant contact around implants with different diameters. In addition, it was evaluated if resonance frequency is able to detect a difference between stable and rotation mobile ("spinning") implants. Implants with diameters of 3.3, 4.1 and 4.8 mm were placed in a purposely designed metal mould where liquid polyurethane resin was then poured to obtain a simulated bone-implant specimen. By regulating the mould, it was possible to create the following simulated bone-implant contact groups: 3.3 mm (198.6 mm(2)); 4.1 mm (198.8 mm(2)); 4.8 mm (200.2 mm(2)); 4.8 mm (231.7 mm(2)); 4.8 mm (294.7 mm(2)). Each group included 10 specimens. After resin setting, resonance frequency was measured. On the last group, measurements were repeated after establishing implant rotational mobility. One-way ANOVA tests with post hoc comparisons, a Pearson's correlation coefficient and a t-test for repeated measurements were used to evaluate statistically significant differences. Implants with different diameters but with the same amount of simulated osseointegration revealed no differences in resonance frequency. On the contrary, an increase of simulated bone-implant contact resulted in significantly higher resonance frequency. A clear direct linear correlation resulted between resonance frequency and simulated bone-implant contact. Furthermore, a significant difference resulted between resonance frequency measured before and after creation of rotational mobility. Within the conditions of this study, the secondary stability was correlated with the simulated bone-implant contact. In addition, resonance frequency was able to discern between stable and rotation mobile implants. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Isotachophoresis in narrow-bore tubes. Influence of the diameter of the separation compartment

    NARCIS (Netherlands)

    Verheggen, T.P.E.M.; Mikkers, F.E.P.; Everaerts, F.M.

    1977-01-01

    The importance of the inside diameter of the separation compartment of electrophoretic equipment in which tubes are used in achieving optimal stabilization against conventive disturbances and for limiting the temperature increase is demonstrated. Both from a theoretical point of view and

  2. Clinical Evaluation of Small Diameter Straumann Implants in Partially Edentulous Patients: A 5-Year Retrospective Study

    Directory of Open Access Journals (Sweden)

    S. OZER

    2011-06-01

    Full Text Available Objective: The aim of the present study was to retrospectively evaluate small-diameter (3.3 mm Straumann® dental implants placed in the maxilla or the mandible over a period of 5 years in function.Materials and Methods: Twenty- eight partially edentulous patients received a total of 48 implants over a 5-year period. After the standard healing period (3 to 6 months, the implants were restored with single-tooth prostheses or fixed partial dentures. All patients were followed according to a strict maintenance program with regular recalls. The cumulative survival rates of implants were analyzed and prosthetic complications were assessed.Results: After 5 years of function, one single 10-mm-long implant in the maxillary premolar region was lost because of recurrent peri-implant infection in a female patient. Two single 10-mm-long maxillary implants placed in the posterior region were lost due to body fracture. The cumulative 5-year survival rate of the implants was 93.75 %. The most common prosthetic complication was loosening of the occlusal screw.Conclusion: Within the limited observation period and the number of patients included in this study, it may be concluded that the use of small-diameter implants appears to be predictable if clinical guidelines are followed and appropriate prosthetic restorations are provided. However, it should be noted that fatigue fracture may occur.

  3. An experimental study on counter current flow limitation in annular narrow gaps with large diameter

    Energy Technology Data Exchange (ETDEWEB)

    Park, Rae Joon; Jeong, Ji Whan; Lee, Sung Jin; Cho, Young Ro; Ha, Kwang Sun; Kim, Sang Baik; Kim, Hee Dong [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-04-01

    The present study intends to carry out CCFL experiment with the same gap size as the CHFG facility and suggest an empirical correlation in order to provide basic information useful to development of an empirical critical-power correlation. The present facility consists of water accumulator tank, test section, DC pump, air regulator, valves and sensors. Air and water are used as working fluids. The experiments are carried out at the atmospheric pressure. Differential pressure between the gap ends, liquid and gas phase flow rates, temperature, lower plenum pressure are measured.Measured values are expressed in terms of Wallis' parameter using gap size as a characteristic length. There is a big difference between the present experimental results and the Koizumi et al.'s results, but the present experimental results are very similar to the Richter et al.'s results. The present results agree well with the Osakabe and Kawasaki's results. In comparison of present experiments with the Koizumi et al.'s experiments, gap thickness is similar, but the diameter of the present is bigger than that of Koizumi et al.'s experiments. In comparison of present experiments with the Richter et al.'s experiments, diameter is similar, but the gap thickness of the present is smaller than that of Richter et al.'s experiments. It is judged from these results that correlation development on CCFL to consider gap thickness is reasonable at similar condition of diameter.The developed correlation will be used to develop the CHFG model. 36 refs., 26 figs., 7 tabs. (Author)

  4. Immediate provisionalization in the esthetic zone: 1-year interim results from a prospective single-cohort multicenter study evaluating 3.0-mm-diameter tapered implants.

    Science.gov (United States)

    Kolinski, Martin; Hess, Pablo; Leziy, Sonia; Friberg, Bertil; Bellucci, Gionata; Trisciuoglio, Davide; Wagner, Wilfried; Moergel, Maximilian; Pozzi, Alessandro; Wiltfang, Jörg; Behrens, Eleonore; Zechner, Werner; Vasak, Christoph; Weigl, Paul

    2018-07-01

    The aim of this interim analysis of a 5-year prospective multicenter study is to evaluate clinical and radiological performance of immediately provisionalized 3.0-mm-diameter tapered implants. Patients needing implant rehabilitation of maxillary lateral incisors or mandibular lateral and central incisors were treated with 3.0-mm-diameter implants placed in extraction or healed sites and immediately provisionalized. Clinical and radiographic examinations were performed at implant insertion, 6 months thereafter, and are ongoing. Marginal bone levels and changes, complications, the papilla, plaque, and bleeding indices, and the pink esthetic score (PES) were evaluated at each follow-up visit. Of 112 enrolled patients, 77 patients (91 implants) met the inclusion criteria. Seventy-one patients with 82 implants completed the 1-year follow-up. Three implants failed yielding a CSR of 96.7%. All failures occurred within the first 3 months after implant insertion. Marginal bone level changes from insertion to 6 months was - 0.57 ± 1.30 mm (n = 75) and from insertion to 12 months - 0.25 ± 1.38 mm (n = 72). Fifteen non-serious complications were recorded. Papilla index score and PES improved at the 1-year follow-up. Plaque formation and bleeding-on-probing showed no statistically significant differences between the 6-month and the 1-year visit. This 1-year analysis demonstrated high survival, stable bone levels, and healthy soft tissue with 3.0-mm-diameter implants. Narrow diameter implants are a safe and predictable treatment option in patients with limited bone volume and/or limited interdental space and eligible for immediate loading protocols.

  5. Refined Synthesis and Characterization of Controlled Diameter, Narrow Size Distribution Microparticles for Aerospace Research Applications

    Science.gov (United States)

    Tiemsin, Pacita I.; Wohl, Christopher J.

    2012-01-01

    Flow visualization using polystyrene microspheres (PSL)s has enabled researchers to learn a tremendous amount of information via particle based diagnostic techniques. To better accommodate wind tunnel researchers needs, PSL synthesis via dispersion polymerization has been carried out at NASA Langley Research Center since the late 1980s. When utilizing seed material for flow visualization, size and size distribution are of paramount importance. Therefore, the work described here focused on further refinement of PSL synthesis and characterization. Through controlled variation of synthetic conditions (chemical concentrations, solution stirring speed, temperature, etc.) a robust, controllable procedure was developed. The relationship between particle size and salt concentration, MgSO4, was identified enabling the determination of PSL diameters a priori. Suggestions of future topics related to PSL synthesis, stability, and size variation are also described.

  6. Strain analysis of different diameter Morse taper implants under overloading compressive conditions

    Directory of Open Access Journals (Sweden)

    Carolina Guimarães CASTRO

    2015-01-01

    Full Text Available The aim of this study was to evaluate the amount of deformation from compression caused by different diameters of Morse taper implants and the residual deformation after load removal. Thirty Morse taper implants lacking external threads were divided into 3 groups (n = 10 according to their diameter as follows: 3.5 mm, 4.0 mm and 5.0 mm. Two-piece abutments were fixed into the implants, and the samples were subjected to compressive axial loading up to 1500 N of force. During the test, one strain gauge remained fixed to the cervical portion of each implant to measure the strain variation. The strain values were recorded at two different time points: at the maximum load (1500 N and 60 seconds after load removal. To calculate the strain at the implant/abutment interface, a mathematical formula was applied. Data were analyzed using a one-way Anova and Tukey’s test (α = 0.05. The 5.0 mm diameter implant showed a significantly lower strain (650.5 μS ± 170.0 than the 4.0 mm group (1170.2 μS ± 374.7 and the 3.5 mm group (1388.1 μS ± 326.6 (p < 0.001, regardless of the load presence. The strain values decreased by approximately 50% after removal of the load, regardless of the implant diameter. The 5.0 mm implant showed a significantly lower strain at the implant/abutment interface (943.4 μS ± 504.5 than the 4.0 mm group (1057.4 μS ± 681.3 and the 3.5 mm group (1159.6 μS ± 425.9 (p < 0.001. According to the results of this study, the diameter influenced the strain around the internal and external walls of the cervical region of Morse taper implants; all diameters demonstrated clinically acceptable values of strain.

  7. Influence of platform diameter in the reliability and failure mode of extra-short dental implants.

    Science.gov (United States)

    Bordin, Dimorvan; Bergamo, Edmara T P; Bonfante, Estevam A; Fardin, Vinicius P; Coelho, Paulo G

    2018-01-01

    To evaluate the influence of implant diameter in the reliability and failure mode of extra-short dental implants. Sixty-three extra-short implants (5mm-length) were allocated into three groups according to platform diameter: Ø4.0-mm, Ø5.0-mm, and Ø6.0-mm (21 per group). Identical abutments were torqued to the implants and standardized crowns cemented. Three samples of each group were subjected to single-load to failure (SLF) to allow the design of the step-stress profiles, and the remaining 18 were subjected to step-stress accelerated life-testing (SSALT) in water. The use level probability Weibull curves, and the reliability (probability of survival) for a mission of 100,000 cycles at 100MPa, 200MPa, and 300MPa were calculated. Failed samples were characterized in scanning electron microscopy for fractographic inspection. No significant difference was observed for reliability regarding implant diameter for all loading missions. At 100MPa load, all groups showed reliability higher than 99%. A significant decreased reliability was observed for all groups when 200 and 300MPa missions were simulated, regardless of implant diameter. At 300MPa load, the reliability was 0%, 0%, and 5.24%, for Ø4.0mm, Ø5.0mm, and Ø6.0mm, respectively. The mean beta (β) values were lower than 0.55 indicating that failures were most likely influenced by materials strength, rather than damage accumulation. The Ø6.0mm implant showed significantly higher characteristic stress (η = 1,100.91MPa) than Ø4.0mm (1,030.25MPa) and Ø5.0mm implant (η = 1,012.97MPa). Weibull modulus for Ø6.0-mm implant was m = 7.41, m = 14.65 for Ø4.0mm, and m = 11.64 for Ø5.0mm. The chief failure mode was abutment fracture in all groups. The implant diameter did not influence the reliability and failure mode of 5mm extra-short implants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique.

    Science.gov (United States)

    Hattingh, André C; De Bruyn, Hugo; Ackermann, Andrew; Vandeweghe, Stefan

    Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with much larger socket dimensions, make it amenable to the use of ultrawide-diameter dental implants. This article describes a practical, sequenced technique that can be used predictably for immediate implant placement in maxillary and mandibular first molar sockets, using a dry skull model for clarification. This detailed description is based on the experience of more than 580 clinical cases over a 10-year period.

  9. Biomechanical optimization of implant diameter and length for immediate loading: a nonlinear finite element analysis.

    Science.gov (United States)

    Kong, Liang; Gu, Zexu; Li, Tao; Wu, Junjie; Hu, Kaijin; Liu, Yanpu; Zhou, Hongzhi; Liu, Baolin

    2009-01-01

    A nonlinear finite element method was applied to examine the effects of implant diameter and length on the maximum von Mises stresses in the jaw, and to evaluate the maximum displacement of the implant-abutment complex in immediate-loading models. The implant diameter (D) ranged from 3.0 to 5.0 mm and implant length (L) ranged from 6.0 to 16.0 mm. The results showed that the maximum von Mises stress in cortical bone was decreased by 65.8% under a buccolingual load with an increase in D. In cancellous bone, it was decreased by 71.5% under an axial load with an increase in L. The maximum displacement in the implant-abutment complex decreased by 64.8% under a buccolingual load with an increase in D. The implant was found to be more sensitive to L than to D under axial loads, while D played a more important role in enhancing its stability under buccolingual loads. When D exceeded 4.0 mm and L exceeded 11.0 mm, both minimum stress and displacement were obtained. Therefore, these dimensions were the optimal biomechanical selections for immediate-loading implants in type B/2 bone.

  10. Influence of the implant-abutment connection design and diameter on the screw joint stability.

    Science.gov (United States)

    Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung; Jeong, Chang-Mo

    2014-04-01

    This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). THE POSTLOAD REMOVAL TORQUE VALUE WAS HIGH IN THE FOLLOWING ORDER WITH REGARD TO MAGNITUDE: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.

  11. Influence of the implant-abutment connection design and diameter on the screw joint stability

    Science.gov (United States)

    Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung

    2014-01-01

    PURPOSE This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). RESULTS The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate. PMID:24843398

  12. Effect of implantoplasty on fracture resistance and surface roughness of standard diameter dental implants.

    Science.gov (United States)

    Costa-Berenguer, Xavier; García-García, Marta; Sánchez-Torres, Alba; Sanz-Alonso, Mariano; Figueiredo, Rui; Valmaseda-Castellón, Eduard

    2018-01-01

    To assess the effect of implantoplasty on the fracture resistance, surface roughness, and macroscopic morphology of standard diameter (4.1 mm) external connection dental implants. An in vitro study was conducted in 20 screw-shaped titanium dental implants with an external connection. In 10 implants, the threads and surface were removed and polished with high-speed burs (implantoplasty), while the remaining 10 implants were used as controls. The final implant dimensions were recorded. The newly polished surface quality was assessed by scanning electron microscopy (SEM) and by 3D surface roughness analysis using a confocal laser microscope. Finally, all the implants were subjected to a mechanical pressure resistance test. A descriptive analysis of the data was made. Also, Student's t tests were employed to detect differences regarding the compression tests. Implantoplasty was carried out for a mean time of 10 min and 48 s (standard deviation (SD) of 1 min 22 s). Macroscopically, the resulting surface had a smooth appearance, although small titanium shavings and silicon debris were present. The final surface roughness (S a values 0.1 ± 0.02 μm) was significantly lower than that of the original (0.75 ± 0.08 μm S a ) (p = .005). There was minimal reduction in the implant's inner body diameter (0.19 ± 0.03 mm), and no statistically significant differences were found between the test and control implants regarding the maximum resistance force (896 vs 880 N, respectively). Implantoplasty, although technically demanding and time-consuming, does not seem to significantly alter fracture resistance of standard diameter external connection implants. A smooth surface with S a values below 0.1 μm can be obtained through the use of silicon polishers. A larger sample is required to confirm that implantoplasty does not significantly affect the maximum resistance force of standard diameter external connection implants. © 2017 John Wiley & Sons A/S. Published

  13. The cochlear implant and possibilities for narrowing the remaining gaps between prosthetic and normal hearing

    Directory of Open Access Journals (Sweden)

    Blake S. Wilson

    2017-12-01

    Full Text Available Background: The cochlear implant has become the standard of care for severe or worse losses in hearing and indeed has produced the first substantial restoration of a lost or absent human sense using a medical intervention. However, the devices are not perfect and many efforts to narrow the remaining gaps between prosthetic and normal hearing are underway. Objective: To assess the present status of cochlear implants and to describe possibilities for improving them. Results: The present-day devices work well in quiet conditions for the great majority of users. However, not all users have high levels of speech reception in quiet and nearly all users struggle with speech reception in typically noisy acoustic environments. In addition, perception of sounds more complex than speech, such as most music, is generally poor unless residual hearing at low frequencies can be stimulated acoustically in conjunction with the electrical stimuli provided by the implant. Possibilities for improving the present devices include increasing the spatial specificity of neural excitation by reducing masking effects or with new stimulus modes; prudent pruning of interfering or otherwise detrimental electrodes from the stimulation map; a further relaxation in the criteria for implant candidacy, based on recent evidence from persons with high levels of residual hearing and to allow many more people to benefit from cochlear implants; and “top down” or “brain centric” approaches to implant designs and applications. Conclusions: Progress in the development of the cochlear implant and related treatments has been remarkable but room remains for improvements. The future looks bright as there are multiple promising possibilities for improvements and many talented teams are pursuing them. Keywords: Auditory prosthesis, Cochlear implant, Cochlear prosthesis, Deafness, Neural prosthesis

  14. Tuning the electronic properties by width and length modifications of narrow-diameter carbon nanotubes for nanomedicine

    KAUST Repository

    Poater, Albert

    2012-10-01

    The distinctive characteristics of nanoparticles, resulting from properties that arise at the nano-scale, underlie their potential applications in the biomedical sector. However, the very same characteristics also result in widespread concerns about the potentially toxic effects of nanoparticles. Given the large number of nanoparticles that are being developed for possible biomedical use, there is a need to develop rapid screening methods based on in silico methods. This study illustrates the application of conceptual Density Functional Theory (DFT) to some carbon nanotubes (CNTs) optimized by means of static DFT calculations. The computational efforts are focused on the geometry of a family of packed narrow-diameter carbon nanotubes (CNTs) formed by units from four to twelve carbons evaluating the strength of the C-C bonds by means of Mayer Bond Orders (MBO). Thus, width and length are geometrical features that might be used to tune the electronic properties of the CNTs. At infinite length, partial semi-conductor characteristics are expected. © 2012 Bentham Science Publishers.

  15. Tuning the electronic properties by width and length modifications of narrow-diameter carbon nanotubes for nanomedicine

    KAUST Repository

    Poater, Albert; Saliner, Ana Gallegos; Cavallo, Luigi; Poch, Manel P.; Solà , Miquel; Worth, Andrew P.

    2012-01-01

    The distinctive characteristics of nanoparticles, resulting from properties that arise at the nano-scale, underlie their potential applications in the biomedical sector. However, the very same characteristics also result in widespread concerns about the potentially toxic effects of nanoparticles. Given the large number of nanoparticles that are being developed for possible biomedical use, there is a need to develop rapid screening methods based on in silico methods. This study illustrates the application of conceptual Density Functional Theory (DFT) to some carbon nanotubes (CNTs) optimized by means of static DFT calculations. The computational efforts are focused on the geometry of a family of packed narrow-diameter carbon nanotubes (CNTs) formed by units from four to twelve carbons evaluating the strength of the C-C bonds by means of Mayer Bond Orders (MBO). Thus, width and length are geometrical features that might be used to tune the electronic properties of the CNTs. At infinite length, partial semi-conductor characteristics are expected. © 2012 Bentham Science Publishers.

  16. Small-diameter dental implants: An adjunct for retention, stability, and comfort for the edentulous patient

    Directory of Open Access Journals (Sweden)

    Antonio Scarano

    2012-10-01

    Full Text Available Aim: Studies have shown that mandibular implant overdentures significantly increase satisfaction and quality of life of edentulous elders. Improved chewing ability appears to have a positive impact on nutritional state. Materials and methods: Forty edentulous subjects received four permucosal mini-implants for overdentures in the interforamina region of the mandible. Almost all participants were still satisfied with their overdentures. Participant satisfaction concerning retention and stability of the mandibular overdenture was assessed. A micro invasive technique was adopted, without open flap and performed in one chirurgical step; this technique can be used also in the so-called “highrisk” patients (anticoagulant terapy, diabetes, etc. Results and conclusion: Results and conclusion The results suggest that a mandibular overdenture retained by 4 mini-implants may be the best treatment strategy for edentulous people with atrophic ridges. The use of mini-implants is in many cases a good clinical alternative to the use of larger diameter implants, in that they enable to reduce surgical time, bleeding, postoperative discomfort and healing time.

  17. Influence of the Diameter of Dental Implants Replacing Single Molars: 3- to 6-Year Follow-Up.

    Science.gov (United States)

    Mendonça, Jose Alfredo; Senna, Plinio Mendes; Francischone, Carlos Eduardo; Francischone Junior, Carlos Eduardo; Sotto-Maior, Bruno Salles

    The aim of this study was to evaluate the influence of the implant diameter on marginal bone remodeling around dental implants replacing single molars after a follow-up period of 3 to 6 years. Patients who received dental implants with an external hexagon platform in healed sites to support a single metal-ceramic crown in the molar region were recalled to the office. The implantation sites and implant length information were recorded, and the implants were divided according to the implant diameter: regular (RP) or wide (WP). Each implant was assessed by digital periapical radiography, using a sensor holder for the paralleling technique. The marginal bone remodeling was determined as the distance from the implant platform to the first bone-to-implant contact, and the known implant length was used to calibrate the images in the computer software. The follow-up measurements were compared with those obtained from the radiograph taken at the time of prosthetic loading to determine the late bone remodeling. The independent t test was used to compare data. A total of 67 implants from 46 patients were evaluated with a mean follow-up period of 4.5 ± 1.0 years. The RP group comprised 36 implants from 29 patients (mean age: 58.3 ± 10.6 years), while 31 implants from 17 patients (mean age: 56.9 ± 11.5 years) were included in the WP group. The RP group presented lower survival rates (86.1%) than the WP group (100.0%). Similar marginal bone loss (P implants exhibited lower incidence failures, the bone levels were similar after the prosthetic loading around regular- and wide-diameter implants supporting single molar crowns.

  18. Wide-diameter locking-taper implants: a prospective clinical study with 1 to 10-year follow-up

    Directory of Open Access Journals (Sweden)

    C. Mangano

    2014-06-01

    Full Text Available Aim: Wide-diameter implants (WDIs, diameter ≥4.5 mm are increasingly being used in patients with poor bone quality and reduced bone height. The aim of this study was to evaluate the survival rate, peri-implant bone loss, biological and prosthetic complications of wide-diameter (4.8 mm locking-taper implants used in the restoration of partially and fully edentulous patients. Materials and methods: Between January 2002 and December 2011, all patients referred to a private clinic for treatment with WDIs were considered for inclusion in the study. At each annual follow-up session, clinical and radiographic parameters were assessed: the outcome measurements were implant failure, peri-implant bone loss (distance between the implant shoulder and the first visible bone-to-implant contact: DIB, biological and prosthetic complications. The cumulative survival rate (CSR was assessed using the Kaplan-Meier estimator; Log-rank was applied to evaluate correlations between the study variables. The statistical analysis was performed at the patient and at the implant level. Results: A total of 438 WDIs were placed in 411 patients. Four implants failed, for a CSR of 99% (patient-based and 99.1% (implant-based at 10-year follow-up. The CSR did not differ significantly with respect to patients’ gender, age, smoking or parafunctional habit, implant location, position, length, bone type or prosthetic restoration. A mean DIB of 0.34 mm (± 0.23, 0.45 mm (± 0.27 and 0.75 mm (± 0.33 was shown at the 1-, 5- and 10-year follow-up examination. Conclusions: Wide-diameter, locking-taper implants can be a good treatment option for the rehabilitation of partially and fully edentulous patients over the long term.

  19. Impact of Intentional Overload on Joint Stability of Internal Implant-Abutment Connection System with Different Diameter.

    Science.gov (United States)

    Lee, Ji-Hye; Lee, Won; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    2017-09-05

    To evaluate the axial displacement of the implant-abutment assembly of different implant diameter after static and cyclic loading of overload condition. An internal conical connection system with three diameters (Ø 4.0, 4.5, and 5.0) applying identical abutment dimension and the same abutment screw was evaluated. Axial displacement of abutment and reverse torque loss of abutment screw were evaluated under static and cyclic loading conditions. Static loading test groups were subjected to vertical static loading of 250, 400, 500, 600, 700, and 800 N consecutively. Cyclic loading test groups were subjected to 500 N cyclic loading to evaluate the effect of excessive masticatory loading. After abutment screw tightening for 30 Ncm, axial displacement was measured upon 1, 3, 10, and 1,000,000 cyclic loadings of 500 N. Repeated-measure ANOVA and 2-way ANOVA were used for statistical analysis (α = 0.05). The increasing magnitude of vertical load and thinner wall thickness of implant increased axial displacement of abutment and reverse torque loss of abutment screw (p < 0.05). Implants in the Ø 5.0 diameter group demonstrated significantly low axial displacement, and reverse torque loss after static loading than Ø 4.0 and Ø 4.5 diameter groups (p < 0.05). In the cyclic loading test, all diameter groups of implant showed significant axial displacement after 1 cycle of loading of 500 N (p < 0.05). There was no significant axial displacement after 3, 10, or 1,000,000 cycles of loading (p = 0.603). Implants with Ø 5.0 diameter demonstrated significantly low axial displacement and reverse torque loss after the cyclic and static loading of overload condition. © 2017 by the American College of Prosthodontists.

  20. Device for film deposition and implantation of ions inside pipes of low diameter

    International Nuclear Information System (INIS)

    Pogrebnjak, A.D.; Perekrjostov, V.I.; Tyurin, Yu.N.; Wood, B.P.

    2002-01-01

    Two principally new devices, which can be applied to deposit coatings inside the pipes of low diameter, have been developed. The thickness of coatings and films can be varied. To deposit coatings of a low thickness (about 2 nm) on inside pipe walls using a vacuum-arc source and a sputtering device, which is composed of the pipe applied for anode cooling, the constant magnet, the magnetic circuit, the anode, the cathode, the pipe subjected for coating deposition, the cathode holder, etc. Using this device, we have deposited TiC, Ta, Cr, TiN coatings of various thickness ranging from scores of nano-meters to several micro-meters and with very good adhesion to the substrate. To increase adhesion, we applied 10 to 20 kV voltage during ion implantation to the substrate. To study element and structure composition, we applied RBS, TEM, SEM, XRD analyses, micro-hardness, wear resistance tests and also those for corrosion resistance in acid media. Another version of the source was based on the pulsed plasma-detonation technology and applied an evaporating electrode (for implantation) and a powder, which was injected into a plasma jet. The jet velocity reached several kilometers per second. Current of several kilo-amps passed through the plasma jet and increased its energy. The produced in this way coating thickness reached 30 to 400 micro-meter. Application of the vacuum-arc source for subsequent coating deposition allowed us to improve the servicing characteristics of surface layers. We have deposited NiAl, CoAl, A1 2 O 3 , WC-Co, Hastelloy and stainless steel SS316L

  1. Osseointegration of Implants Surface-Treated with Various Diameters of TiO2 Nanotubes in Rabbit

    Directory of Open Access Journals (Sweden)

    Cheul-Goo Kang

    2015-01-01

    Full Text Available The aim of this study was to evaluate the osseointegration of implants which were surface-treated with various diameters of TiO2 nanotubes (30 nm, 70 nm, and 100 nm in rabbit. Resorbable blast media (RBM surfaced implants (Osstem, Busan, Korea 3.5 mm in diameter and 8.5 mm in length were designated as the control group and the implants surface-treated with various diameters of nanotubes (30 nm, 70 nm, and 100 nm with the same shapes were designated as the experimental groups. The implants were maintained unloaded for 4 and 12 weeks. After this period, the animals were sacrificed and micro-CT analysis, histomorphometric analysis (bone to implant contact (BIC, bone volume (BV, and removal torque test were performed. Micro-CT analysis, histomorphometric analysis, and removal torque test results all showed the similar pattern, showing that 70 nm experimental group had the highest value at 4 weeks while 30 nm experimental group had the highest value at 12 weeks. Therefore, on the basis of the results above, it can be concluded that 30 nm and 70 nm TiO2 nanotubes may have positive effects on osteogenesis and osseointegration depending on the healing time.

  2. Osseointegration of Implants Surface-Treated with Various Diameters of TiO2 Nano tubes in Rabbit

    International Nuclear Information System (INIS)

    Kang, Ch.G.; Park, Y.B.; Choi, H.; Lee, K.W.; Shim, J.S.; Oh, S.; Choi, S.H.

    2014-01-01

    The aim of this study was to evaluate the osseointegration of implants which were surface-treated with various diameters of TiO 2 nano tubes (30 nm, 70 nm, and 100 nm) in rabbit. Resorbable blast media (RBM) surfaced implants (Osstem, Busan, Korea) 3.5 mm in diameter and 8.5 mm in length were designated as the control group and the implants surface-treated with various diameters of nano tubes (30 nm, 70 nm, and 100 nm) with the same shapes were designated as the experimental groups. The implants were maintained unloaded for 4 and 12 weeks. After this period, the animals were sacrificed and micro-CT analysis, histomorphometric analysis (bone to implant contact (BIC), bone volume (BV)), and removal torque test were performed. Micro-CT analysis, histomorphometric analysis, and removal torque test results all showed the similar pattern, showing that 70 nm experimental group had the highest value at 4 weeks while 30 nm experimental group had the highest value at 12 weeks. Therefore, on the basis of the results above, it can be concluded that 30 nm and 70 nm TiO 2 nano tubes may have positive effects on osteogenesis and osseointegration depending on the healing time

  3. Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force.

    Science.gov (United States)

    Lu, Ying-juan; Chang, Shao-hai; Ye, Jian-tao; Ye, Yu-shan; Yu, Yan-song

    2015-01-01

    Stress on the bone surrounding dental micro-implants affects implant success. To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. The Max EQS of the CF exceeded that of the SF (Pimplant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm.

  4. Changes in the fractal dimension, feret diameter, and lacunarity of mandibular alveolar bone during initial healing of dental implants.

    Science.gov (United States)

    Önem, Erinç; Baksı, B Güniz; Sogur, Elif

    2012-01-01

    To evaluate the combination of fractal dimension (FD), lacunarity, and Feret diameter (FeD) to quantitatively characterize structural changes of mandibular alveolar bone around dental implants during initial healing. Three standard-sized regions of interest (ROIs) (mesial and distal crest and apical area) around implants and three ROIs of the same size in the alveolar bone on the contralateral side were analyzed on digital panoramic images. FD was calculated using the box-counting method, and lacunarity was calculated using the FracLac plugin of Image J software. FeD was measured in the same ROIs. Comparisons of the groups were done with the Dunnett test. Forty-two implants in the posterior mandibles of 21 patients were used for FD measurements. A total of 189 ROIs was segmented into binary images. Mean FD values for mesial, distal, and apical ROIs around implants were 1.26, 1.36, and 1.4, respectively. The mean FD of alveolar bone around premolars/molars was 1.39 for all ROIs. The mean FeD for mesial, distal, and apical ROIs around implants was 7.63, 7.86, and 8.02, respectively, whereas it ranged between 7.88 and 8.13 for premolar teeth. Mean lacunarity values for mesial, distal, and apical ROIs around implants were 0.53, 0.51, and 0.48, respectively. Lacunarity values for ROIs around premolars ranged between 0.45 and 0.50. No significant differences were observed in FD, FeD, or lacunarity measurements between ROIs around implants and around teeth. The satisfactory healing of bone following implant placement may be monitored by calculating FD, lacunarity, and FeD using digital panoramic images. Although preliminary, these values may alert the practitioner to any implants with loss of stability.

  5. Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: In-vitro experimental and three-dimensional finite element analyses.

    Science.gov (United States)

    Wu, Aaron Yu-Jen; Hsu, Jui-Ting; Chee, Winston; Lin, Yun-Te; Fuh, Lih-Jyh; Huang, Heng-Li

    2016-09-01

    Small-diameter dental implants are associated with a higher risk of implant failure. This study used both three-dimensional finite-element (FE) simulations and in-vitro experimental tests to analyze the stresses and strains in both the implant and the surrounding bone when using one-piece (NobelDirect) and two-piece (NobelReplace) small-diameter implants, with the aim of understanding the underlying biomechanical mechanisms. Six experimental artificial jawbone models and two FE models were prepared for one-piece and two-piece 3.5-mm diameter implants. Rosette strain gauges were used for in-vitro tests, with peak values of the principal bone strain recorded with a data acquisition system. Implant stability as quantified by Periotest values (PTV) were also recorded for both types of implants. Experimental data were analyzed statistically using Wilcoxon's rank-sum test. In FE simulations, the peak value and distribution of von-Mises stresses in the implant and bone were selected for evaluation. In in-vitro tests, the peak bone strain was 42% lower for two-piece implants than for one-piece implants. The PTV was slightly lower for one-piece implants (PTV = -6) than for two-piece implants (PTV = -5). In FE simulations, the stresses in the bone and implant were about 23% higher and 12% lower, respectively, for one-piece implants than those for two-piece implants. Due to the higher peri-implant bone stresses and strains, one-piece implants (NobelDirect) might be not suitable for use as small-diameter implants. Copyright © 2016. Published by Elsevier B.V.

  6. Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.

    Science.gov (United States)

    Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja

    Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.

  7. A retrospective study of the hearing results obtained after stapedotomy by the implantation of two Teflon pistons with a different diameter

    NARCIS (Netherlands)

    Grolman, W.; Tange, R. A.; de Bruijn, A. J.; Hart, A. A.; Schouwenburg, P. F.

    1997-01-01

    This study reports the evaluation of hearing results after implantation of a Teflon piston of a different diameter in cases of otosclerosis requiring stapedotomy. By random selection, a Teflon piston with a shaft diameter of 0.3 mm was inserted in 34 cases and a piston with a shaft diameter of 0.4

  8. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique

    NARCIS (Netherlands)

    Hattingh, A.C.; Bruyn, H. de; Ackermann, A.; Vandeweghe, S.

    2018-01-01

    Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with

  9. Recognition and Comprehension of "Narrow Focus" by Young Adults With Prelingual Hearing Loss Using Hearing Aids or Cochlear Implants.

    Science.gov (United States)

    Segal, Osnat; Kishon-Rabin, Liat

    2017-12-20

    The stressed word in a sentence (narrow focus [NF]) conveys information about the intent of the speaker and is therefore important for processing spoken language and in social interactions. The ability of participants with severe-to-profound prelingual hearing loss to comprehend NF has rarely been investigated. The purpose of this study was to assess the recognition and comprehension of NF by young adults with prelingual hearing loss compared with those of participants with normal hearing (NH). The participants included young adults with hearing aids (HA; n = 10), cochlear implants (CI; n = 12), and NH (n = 18). The test material included the Hebrew Narrow Focus Test (Segal, Kaplan, Patael, & Kishon-Rabin, in press), with 3 subtests, which was used to assess the recognition and comprehension of NF in different contexts. The following results were obtained: (a) CI and HA users successfully recognized the stressed word, with the worst performance for CI; (b) HA and CI comprehended NF less well than NH; and (c) the comprehension of NF was associated with verbal working memory and expressive vocabulary in CI users. Most CI and HA users were able to recognize the stressed word in a sentence but had considerable difficulty understanding it. Different factors may contribute to this difficulty, including the memory load during the task itself and linguistic and pragmatic abilities. https://doi.org/10.23641/asha.5572792.

  10. Influence of different abutment diameter of implants on the peri-implant stress in the crestal bone: A three-dimensional finite element analysis--In vitro study.

    Science.gov (United States)

    Aradya, Anupama; Kumar, U Krishna; Chowdhary, Ramesh

    2016-01-01

    The study was designed to evaluate and compare stress distribution in transcortical section of bone with normal abutment and platform switched abutment under vertical and oblique forces in posterior mandible region. A three-dimensional finite element model was designed using ANSYS 13.0 software. The type of bone selection for the model was made of type II mandibular bone, having cortical bone thickness ranging from 0.595 mm to 1.515 mm with the crestal region measuring 1.5 mm surrounding dense trabecular bone. The implant will be modulated at 5 mm restorative platform and tapering down to 4.5 mm wide at the threads, 13 mm long with an abutment 3 mm in height. The models will be designed for two situations: (1) An implant with a 5 mm diameter abutment representing a standard platform in the posterior mandible region. (2) An implant with a 4.5 mm diameter abutment representing platform switching in the posterior mandible region. Force application was performed in both oblique and vertical conditions using 100 N as a representative masticatory force. For oblique loading, a force of 100 N was applied at 15° from the vertical axis. von Mises stress analysis was evaluated. The results of the study showed cortical stress in the conventional and platform switching model under oblique forces were 59.329 MPa and 39.952 MPa, respectively. Cortical stress in the conventional and platform switching model under vertical forces was 13.914 MPa and 12.793 MPa, respectively. Results from this study showed the platform switched abutment led to relative decrease in von Mises stress in transcortical section of bone compared to normal abutment under vertical and oblique forces in posterior mandible region.

  11. Symmetric Electrode Spanning Narrows the Excitation Patterns of Partial Tripolar Stimuli in Cochlear Implants.

    Science.gov (United States)

    Luo, Xin; Wu, Ching-Chih

    2016-12-01

    In cochlear implants (CIs), standard partial tripolar (pTP) mode reduces current spread by returning a fraction of the current to two adjacent flanking electrodes within the cochlea. Symmetric electrode spanning (i.e., separating both the apical and basal return electrodes from the main electrode by one electrode) has been shown to increase the pitch of pTP stimuli, when the ratio of intracochlear return current was fixed. To explain the pitch increase caused by symmetric spanning in pTP mode, this study measured the electrical potentials of both standard and symmetrically spanned pTP stimuli on a main electrode EL8 in five CI ears using electrical field imaging (EFI). In addition, the spatial profiles of evoked compound action potentials (ECAP) and the psychophysical forward masking (PFM) patterns were also measured for both stimuli. The EFI, ECAP, and PFM patterns of a given stimulus differed in shape details, reflecting the different levels of auditory processing and different ratios of intracochlear return current across the measurement methods. Compared to the standard pTP stimuli, the symmetrically spanned pTP stimuli significantly reduced the areas under the curves of the normalized EFI and PFM patterns, without shifting the pattern peaks and centroids (both around EL8). The more focused excitation patterns with symmetric spanning may have caused the previously reported pitch increase, due to an interaction between pitch and timbre perception. Being able to reduce the spread of excitation, pTP mode symmetric spanning is a promising stimulation strategy that may further increase spectral resolution and frequency selectivity with CIs.

  12. Magnet-Retained Two-Mini-Implant Overdenture: Clinical and Mechanical Consideration

    Directory of Open Access Journals (Sweden)

    Yuichi Ishida

    2016-10-01

    Full Text Available Two-implant overdentures have become the accepted treatment for restoring mandibular edentulism. The dimensions of regular implants sometimes limit their use, such as in the case of narrow ridges. Mini-implants with reduced diameters (less than 3.0 mm enable insertion into narrow ridges. A magnet-retained two-mini-implant overdenture system was developed and is described in this paper. Additionally, we describe a clinical mandibular procedure using the system and evaluate its biomechanical performance.

  13. Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments.

    Science.gov (United States)

    Safari, Sina; Hosseini Ghavam, Fereshteh; Amini, Parviz; Yaghmaei, Kaveh

    2018-02-01

    The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specimens were divided into 2 diameter groups: 4.5 mm and 5.5 mm (n=30). For each abutment a CAD/CAM metal coping was manufactured, with an occlusal loop. Each group was sub-divided into 3 sub-groups (n=10). In each subgroup, a different cement type was used: resin-modified glass-ionomer, resin cement and zinc-oxide-eugenol. After incubation and thermocycling, the removal force was measured using a universal testing machine at a cross-head speed of 0.5 mm/min. In zinc-oxide-eugenol group, after removal of the coping, the cement remnants were completely cleaned and the copings were re-cemented with resin cement and re-tested. Two-way ANOVA, post hoc Tukey tests, and paired t-test were used to analyze data (α=.05). The highest pulling force was registered in the resin cement group (414.8 N), followed by the re-cementation group (380.5 N). Increasing the diameter improved the retention significantly ( P =.006). The difference in retention between the cemented and recemented copings was not statistically significant ( P =.40). Resin cement provided retention almost twice as strong as that of the RMGI. Increasing the abutment diameter improved retention significantly. Re-cementation with resin cement did not exhibit any difference from the initial cementation with resin cement.

  14. Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments

    Science.gov (United States)

    Safari, Sina; Amini, Parviz; Yaghmaei, Kaveh

    2018-01-01

    PURPOSE The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. MATERIALS AND METHODS Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specimens were divided into 2 diameter groups: 4.5 mm and 5.5 mm (n=30). For each abutment a CAD/CAM metal coping was manufactured, with an occlusal loop. Each group was sub-divided into 3 sub-groups (n=10). In each subgroup, a different cement type was used: resin-modified glass-ionomer, resin cement and zinc-oxide-eugenol. After incubation and thermocycling, the removal force was measured using a universal testing machine at a cross-head speed of 0.5 mm/min. In zinc-oxide-eugenol group, after removal of the coping, the cement remnants were completely cleaned and the copings were re-cemented with resin cement and re-tested. Two-way ANOVA, post hoc Tukey tests, and paired t-test were used to analyze data (α=.05). RESULTS The highest pulling force was registered in the resin cement group (414.8 N), followed by the re-cementation group (380.5 N). Increasing the diameter improved the retention significantly (P=.006). The difference in retention between the cemented and recemented copings was not statistically significant (P=.40). CONCLUSION Resin cement provided retention almost twice as strong as that of the RMGI. Increasing the abutment diameter improved retention significantly. Re-cementation with resin cement did not exhibit any difference from the initial cementation with resin cement. PMID:29503708

  15. Performance improvement in narrow MuGFETs by gate work function and source/drain implant engineering

    Science.gov (United States)

    Ferain, I.; Duffy, R.; Collaert, N.; van Dal, M. J. H.; Pawlak, B. J.; O'Sullivan, B.; Witters, L.; Rooyackers, R.; Conard, T.; Popovici, M.; van Elshocht, S.; Kaiser, M.; Weemaes, R. G. R.; Swerts, J.; Jurczak, M.; Lander, R. J. P.; De Meyer, K.

    2009-07-01

    At short gate lengths, narrow multiple-gate FETs (MuGFETs) are known to offer superior short channel effect (SCE) control than their bulk Si counterpart [Doyle BS et al. High performance fully-depleted tri-gate CMOS transistors. IEEE Electron Dev Lett 2003;24(4):263-5, van Dal MJH et al. Highly manufacturable FinFETs with sub-10 nm fin width and high aspect ratio fabricated with immersion lithography. In: VLSI Symp Tech Dig; 2007. p. 110-1 [1,2

  16. True-lumen and false-lumen diameter changes in the downstream aorta after frozen elephant trunk implantation.

    Science.gov (United States)

    Berger, Tim; Kreibich, Maximilian; Morlock, Julia; Kondov, Stoyan; Scheumann, Johannes; Kari, Fabian A; Rylski, Bartosz; Siepe, Matthias; Beyersdorf, Friedhelm; Czerny, Martin

    2018-02-19

    To evaluate early and mid-term clinical outcomes and to assess the potential of the frozen elephant trunk technique to induce remodelling of downstream aortic segments in acute and chronic thoracic aortic dissections. Over a 4-year period, 65 patients (48 men, aged 61 ± 12 years) underwent total aortic arch replacement using the frozen elephant trunk technique for acute (n = 31) and chronic (n = 34) thoracic aortic dissections at our institution. We assessed diameter changes at 3 levels: the L1 segment at the stent graft level; the L2 segment at the thoraco-abdominal transition level and the L3 segment at the coeliac trunk level. True-lumen (TL) and false-lumen (FL) diameter changes were assessed at each level. Fifty-six percent of patients had already undergone previous aortic or cardiac surgery. In-hospital mortality was 6%. Symptomatic spinal cord injury was not observed in this series. During a mean follow-up of 12 ± 12 months, late death was observed in 6% of patients. Aortic reinterventions in downstream aortic segments were performed in 28% at a mean of 394 ± 385 days. TL expansion and FL shrinkage were measured in all segments and were observed at each level. This effect was the most pronounced at the level of the stent graft in patients with chronic aortic dissection, TL diameter increased from 15 ± 17 mm before surgery to 28 ± 2 mm (P = 0.001) after 2 years, and the FL diameter decreased from 40 ± 11 mm before surgery to 32 ± 17 mm (P = 0.026). The frozen elephant trunk technique is associated with an excellent clinical outcome in a complex cohort of patients, and also effectively induces remodelling in downstream aortic segments in acute and chronic thoracic aortic dissections. The need for secondary interventions in downstream segments, which mainly depends on the extent of the underlying disease process, remains substantial. Further studies are required to assess the long-term outcome of

  17. Narrow, duplicated internal auditory canal

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, T. [Servico de Neurorradiologia, Hospital Garcia de Orta, Avenida Torrado da Silva, 2801-951, Almada (Portugal); Shayestehfar, B. [Department of Radiology, UCLA Oliveview School of Medicine, Los Angeles, California (United States); Lufkin, R. [Department of Radiology, UCLA School of Medicine, Los Angeles, California (United States)

    2003-05-01

    A narrow internal auditory canal (IAC) constitutes a relative contraindication to cochlear implantation because it is associated with aplasia or hypoplasia of the vestibulocochlear nerve or its cochlear branch. We report an unusual case of a narrow, duplicated IAC, divided by a bony septum into a superior relatively large portion and an inferior stenotic portion, in which we could identify only the facial nerve. This case adds support to the association between a narrow IAC and aplasia or hypoplasia of the vestibulocochlear nerve. The normal facial nerve argues against the hypothesis that the narrow IAC is the result of a primary bony defect which inhibits the growth of the vestibulocochlear nerve. (orig.)

  18. Influence of irradiation (Co60) in pre-implant rabbits embryos: effect on blastocyst diameters and embryos smaller than 2 mm

    International Nuclear Information System (INIS)

    Approbato, Mario S.; Oliveira Moura, Katia K.V. de; Souza Florencio, Rodopiano de; Cunha Junior, Carlos; Garcia, Ricardo; Faria, Renato S.; Benedetti, Leonardo N.; Goulart, Flamarion B.

    1995-01-01

    We studied the effect of ionizing irradiation on 12 New Zealand rabbits (65 embryos), in three different times: at match time (zero hour), two days after and four days after, with two different irradiation doses, 5 c Gy and 10 c Gy. Six rabbits (36 blastocysts) were used as controls. The matching instant was the zero hour. Exactly six days after (± 60 minutes) the embryos of each rabbit was picked up by flushing the uterus with culture media. The embryos were fixed in methanol for 48 hours, and colored with acid Mayer hematoxylin. The following embryos parameters were studied: diameter growth; percentage of embryos smaller than 2 mm. We observed that only the irradiation time influenced the blastocysts diameter (no irradiation dose). There was no relation between percentage of embryos smaller than 2 mm and the irradiation. (author)

  19. Value of Combining Left Atrial Diameter and Amino-terminal Pro-brain Natriuretic Peptide to the CHA2DS2-VASc Score for Predicting Stroke and Death in Patients with Sick Sinus Syndrome after Pacemaker Implantation.

    Science.gov (United States)

    Mo, Bin-Feng; Lu, Qiu-Fen; Lu, Shang-Biao; Xie, Yu-Quan; Feng, Xiang-Fei; Li, Yi-Gang

    2017-08-20

    The CHA2DS2-VASc score is used clinically for stroke risk stratification in patients with atrial fibrillation (AF). We sought to investigate whether the CHA2DS2-VASc score predicts stroke and death in Chinese patients with sick sinus syndrome (SSS) after pacemaker implantation and to evaluate whether the predictive power of the CHA2DS2-VASc score could be improved by combining it with left atrial diameter (LAD) and amino-terminal pro-brain natriuretic peptide (NT-proBNP). A total of 481 consecutive patients with SSS who underwent pacemaker implantation from January 2004 to December 2014 in our department were included. The CHA2DS2-VASc scores were retrospectively calculated according to the hospital medical records before pacemaker implantation. The outcome data (stroke and death) were collected by pacemaker follow-up visits and telephonic follow-up until December 31, 2015. During 2151 person-years of follow-up, 46 patients (9.6%) suffered stroke and 52 (10.8%) died. The CHA2DS2-VASc score showed a significant association with the development of stroke (hazard ratio [HR] 1.45, 95% confidence interval [CI] 1.20-1.75, Ppacemaker implantation. The addition of LAD and NT-proBNP to the CHA2DS2-VASc score improved its predictive power for stroke and death, respectively, in this patient cohort. Future prospective studies are warranted to validate the benefit of adding LAD and NT-proBNP to the CHA2DS2-VASc score for predicting stroke and death risk in non-AF populations.

  20. Maxillary Three-Implant Overdentures Opposing Mandibular Two-Implant Overdentures: 10-Year Surgical Outcomes of a Randomized Controlled Trial.

    Science.gov (United States)

    Ma, Sunyoung; Tawse-Smith, Andrew; De Silva, Rohana K; Atieh, Momen A; Alsabeeha, Nabeel H M; Payne, Alan G T

    2016-06-01

    The surgical placement of four maxillary implants for overdentures may not be obligatory when opposing mandibular two-implant overdentures. To determine 10-year surgical outcomes and implant success of three narrow diameter implants in edentulous maxillae with conventional loading. Forty participants with mandibular two-implant overdentures were randomly allocated for surgery for maxillary overdentures. Using osteotomes, three implants of similar systems were placed with a one-stage procedure and 12-week loading with splinted and unsplinted prosthodontic designs. Marginal bone and stability measurements were done at surgery, 12 weeks, 1-, 2-, 5-, 7-, 10 years. One hundred seventeen implants were placed in 39 participants, with 35 being seen at 1 year; 29 at 2 years; 28 at 5 years; 26 at 7 years; and 23 (59%) at 10 years. Marginal bone loss was 1.35 mm between surgery and 12 weeks; 0.36 mm between 12 weeks and 1 year; 0.48 mm between 1 and 5 years; and 0.22 mm between 5 and 10 years. Implant stability quotients were 56.05, 57.54, 60.88, 58.80, 61.17 at surgery, 12 weeks, 1 year, 5 years, and 10 years. Four-field tables by implant showed success rates of 82% at 1 year; 69.2% at 2 years; 66.7% at 5 years; 61.5% at 7 years; 51.3% at 10 years. Data showed no differences between surgical technique, systems, or prosthodontic designs. Surgical placement with osteotomes of three narrow diameter implants for maxillary overdentures, opposing mandibular two-implant overdentures, is an acceptable approach, subject to strict patient selection. Implant success is independent of prosthodontic design. © 2015 Wiley Periodicals, Inc.

  1. Narrow beam neutron dosimetry.

    Science.gov (United States)

    Ferenci, M Sutton

    2004-01-01

    Organ and effective doses have been estimated for male and female anthropomorphic mathematical models exposed to monoenergetic narrow beams of neutrons with energies from 10(-11) to 1000 MeV. Calculations were performed for anterior-posterior, posterior-anterior, left-lateral and right-lateral irradiation geometries. The beam diameter used in the calculations was 7.62 cm and the phantoms were irradiated at a height of 1 m above the ground. This geometry was chosen to simulate an accidental scenario (a worker walking through the beam) at Flight Path 30 Left (FP30L) of the Weapons Neutron Research (WNR) Facility at Los Alamos National Laboratory. The calculations were carried out using the Monte Carlo transport code MCNPX 2.5c.

  2. Mini implants for definitive prosthodontic treatment: a systematic review.

    Science.gov (United States)

    Bidra, Avinash S; Almas, Khalid

    2013-03-01

    Mini implants are commonly used in orthodontics and for interim prosthodontic treatment, but evidence for their use in definitive prosthodontic treatment is not clear. This systematic review evaluated the mini-implant literature to analyze short-term (1 to 5 years), medium-term (5 to 10 years), and long-term (beyond 10 years) survival rates when used for definitive prosthodontic treatment. An electronic search of the English language literature for articles published between January 1974 and May 2012 was performed by using PubMed and Cochrane databases with predetermined inclusion criteria. Key terms included in the search were mini dental implants, narrow diameter implants, reduced diameter implants, small diameter implants, transitional implants, interim implants, and provisional implants. After a systematic filtering process, the selected articles were subjected to a detailed review, and the data collected were used to calculate the 1-year interval survival rate (ISR) and the cumulative survival rate (CSR). The electronic database search yielded 1807 titles. By scrutinizing the titles and abstracts with inclusion and exclusion criteria, the researchers identified 9 studies of mini implants for definitive prosthodontic treatment. Of the studies identified, 1 was a randomized controlled trial, 2 were prospective studies, and 6 were retrospective studies. The majority of mini implants were placed by using a flapless surgical technique in the mandibular anterior region to support an overdenture. The 1st year ISR was 94.7% and the CSR over a 9-year period, primarily attributed to data from 1 study, was 92.2%. Most implants were immediately loaded and almost all implant failures occurred during the first year after implant placement. For short-term survival, the first year ISR of 94.7% of mini dental implants appears encouraging, but the true 1-year survival rate is unknown, as the minimum follow-up period reported for several implants was less than a year

  3. Clinical evidence on titanium-zirconium dental implants: a systematic review and meta-analysis.

    Science.gov (United States)

    Altuna, P; Lucas-Taulé, E; Gargallo-Albiol, J; Figueras-Álvarez, O; Hernández-Alfaro, F; Nart, J

    2016-07-01

    The use of titanium implants is well documented and they have high survival and success rates. However, when used as reduced-diameter implants, the risk of fracture is increased. Narrow diameter implants (NDIs) of titanium-zirconium (Ti-Zr) alloy have recently been developed (Roxolid; Institut Straumann AG). Ti-Zr alloys (two highly biocompatible materials) demonstrate higher tensile strength than commercially pure titanium. The aim of this systematic review was to summarize the existing clinical evidence on dental NDIs made from Ti-Zr. A systematic literature search was performed using the Medline database to find relevant articles on clinical studies published in the English language up to December 2014. Nine clinical studies using Ti-Zr implants were identified. Overall, 607 patients received 922 implants. The mean marginal bone loss was 0.36±0.06mm after 1 year and 0.41±0.09mm after 2 years. The follow-up period ranged from 3 to 36 months. Mean survival and success rates were 98.4% and 97.8% at 1 year after implant placement and 97.7% and 97.3% at 2 years. Narrow diameter Ti-Zr dental implants show survival and success rates comparable to regular diameter titanium implants (>95%) in the short term. Long-term follow-up clinical data are needed to confirm the excellent clinical performance of these implants. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Peri-implant soft tissue and marginal bone adaptation on implant with non-matching healing abutments: micro-CT analysis.

    Science.gov (United States)

    Finelle, Gary; Papadimitriou, Dimitrios E V; Souza, André B; Katebi, Negin; Gallucci, German O; Araújo, Mauricio G

    2015-04-01

    To assess (i) the outcome of changing the horizontal-offset dimension on the peri-implant soft tissues and the crestal bone and (ii) the effect of different healing abutments (flared vs. straight) on the marginal peri-implant soft tissues and crestal bone. Two-piece dental implants diameters of 3.5 and 4.5 mm were placed at least 1 mm subcrestal in five beagle dogs. Three different investigational groups: (i) 3.5-mm-diameter implant with narrow healing abutment (3.5N), (ii) 4.5-mm-diameter implant with narrow healing abutment (4.5N), and (iii) 3.5-mm-diameter implant with wide healing abutment (3.5W), were assessed. After 4 months of healing, the vertical distance from the marginal crestal bone (MB) to the implant shoulder (IS); the vertical distance from the IS to the first bone-to-implant contact; and the horizontal distance of bone ingrowth on the implant platform were measured with a high-resolution micro-CT (Xradia MicroXCT-200 system). Implants with a narrow healing caps showed an interproximal MB located between 0 and 1 mm above the implant shoulder, while the 3.5W group exhibits a mean value -0.50 mm. As all implants in group 3.5N presented a fBIC located at the level of the IS. For the 4.5N group, the mean fBIC-IS distance was -0.52 mm apically to the IS. For the 3.5WC group, the mean fBIC-IS distance was -1.42 mm. Horizontal bone apposition was only observed for the 3.5N group and the 4.5N group. The dimension of the horizontal offset would play a minimal role in reducing bone remodeling, whereas the configuration of the transmucosal component would directly influence marginal bone remodeling. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Bone Healing Around Dental Implants: Simplified vs Conventional Drilling Protocols at Speed of 400 rpm.

    Science.gov (United States)

    Gil, Luiz Fernando; Sarendranath, Alvin; Neiva, Rodrigo; Marão, Heloisa F; Tovar, Nick; Bonfante, Estevam A; Janal, Malvin N; Castellano, Arthur; Coelho, Paulo G

    This study evaluated whether simplified drilling protocols would provide comparable histologic and histomorphometric results to conventional drilling protocols at a low rotational speed. A total of 48 alumina-blasted and acid-etched Ti-6Al-4V implants with two diameters (3.75 and 4.2 mm, n = 24 per group) were bilaterally placed in the tibiae of 12 dogs, under a low-speed protocol (400 rpm). Within the same diameter group, half of the implants were inserted after a simplified drilling procedure (pilot drill + final diameter drill), and the other half were placed using the conventional drilling procedure. After 3 and 5 weeks, the animals were euthanized, and the retrieved bone-implant samples were subjected to nondecalcified histologic sectioning. Histomorphology, bone-to-implant contact (BIC), and bone area fraction occupancy (BAFO) analysis were performed. Histology showed that new bone was formed around implants, and inflammation or bone resorption was not evident for both groups. Histomorphometrically, when all independent variables were collapsed over drilling technique, no differences were detected for BIC and BAFO; when drilling technique was analyzed as a function of time, the conventional groups reached statistically higher BIC and BAFO at 3 weeks, but comparable values between techniques were observed at 5 weeks; 4.2-mm implants obtained statistically higher BAFO relative to 3.75-mm implants. Based on the present methodology, the conventional technique improved bone formation at 3 weeks, and narrower implants were associated with less bone formation.

  6. Cervical spinal canal narrowing in idiopathic syringomyelia

    International Nuclear Information System (INIS)

    Struck, Aaron F.; Carr, Carrie M.; Shah, Vinil; Hesselink, John R.; Haughton, Victor M.

    2016-01-01

    The cervical spine in Chiari I patient with syringomyelia has significantly different anteroposterior diameters than it does in Chiari I patients without syringomyelia. We tested the hypothesis that patients with idiopathic syringomyelia (IS) also have abnormal cervical spinal canal diameters. The finding in both groups may relate to the pathogenesis of syringomyelia. Local institutional review boards approved this retrospective study. Patients with IS were compared to age-matched controls with normal sagittal spine MR. All subjects had T1-weighted spin-echo (500/20) and T2-weighted fast spin-echo (2000/90) sagittal cervical spine images at 1.5 T. Readers blinded to demographic data and study hypothesis measured anteroposterior diameters at each cervical level. The spinal canal diameters were compared with a Mann-Whitney U test. The overall difference was assessed with a Friedman test. Seventeen subjects were read by two reviewers to assess inter-rater reliability. Fifty IS patients with 50 age-matched controls were studied. IS subjects had one or more syrinxes varying from 1 to 19 spinal segments. Spinal canal diameters narrowed from C1 to C3 and then enlarged from C5 to C7 in both groups. Diameters from C2 to C4 were narrower in the IS group (p < 0.005) than in controls. The ratio of the C3 to the C7 diameters was also smaller (p = 0.004) in IS than controls. Collectively, the spinal canal diameters in the IS were significantly different from controls (Friedman test p < 0.0001). Patients with IS have abnormally narrow upper and mid cervical spinal canal diameters and greater positive tapering between C3 and C7. (orig.)

  7. Cervical spinal canal narrowing in idiopathic syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Struck, Aaron F. [Massachusetts General Hospital, Department of Neurology, Boston, MA (United States); Carr, Carrie M. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Shah, Vinil [University of California San Francisco, Department of Radiology, San Francisco, CA (United States); Hesselink, John R. [University of California San Diego, Department of Radiology, San Diego, CA (United States); Haughton, Victor M. [University of Wisconsin, Department of Radiology, Madison, WI (United States)

    2016-08-15

    The cervical spine in Chiari I patient with syringomyelia has significantly different anteroposterior diameters than it does in Chiari I patients without syringomyelia. We tested the hypothesis that patients with idiopathic syringomyelia (IS) also have abnormal cervical spinal canal diameters. The finding in both groups may relate to the pathogenesis of syringomyelia. Local institutional review boards approved this retrospective study. Patients with IS were compared to age-matched controls with normal sagittal spine MR. All subjects had T1-weighted spin-echo (500/20) and T2-weighted fast spin-echo (2000/90) sagittal cervical spine images at 1.5 T. Readers blinded to demographic data and study hypothesis measured anteroposterior diameters at each cervical level. The spinal canal diameters were compared with a Mann-Whitney U test. The overall difference was assessed with a Friedman test. Seventeen subjects were read by two reviewers to assess inter-rater reliability. Fifty IS patients with 50 age-matched controls were studied. IS subjects had one or more syrinxes varying from 1 to 19 spinal segments. Spinal canal diameters narrowed from C1 to C3 and then enlarged from C5 to C7 in both groups. Diameters from C2 to C4 were narrower in the IS group (p < 0.005) than in controls. The ratio of the C3 to the C7 diameters was also smaller (p = 0.004) in IS than controls. Collectively, the spinal canal diameters in the IS were significantly different from controls (Friedman test p < 0.0001). Patients with IS have abnormally narrow upper and mid cervical spinal canal diameters and greater positive tapering between C3 and C7. (orig.)

  8. Guided proliferation and bone-forming functionality on highly ordered large diameter TiO2 nanotube arrays

    International Nuclear Information System (INIS)

    Zhang, Ruopeng; Wu, Hongliu; Ni, Jiahua; Zhao, Changli; Chen, Yifan; Zheng, Chengjunyi; Zhang, Xiaonong

    2015-01-01

    The significantly enhanced osteoblast adhesion, proliferation and alkaline phosphatase (ALP) activity were observed on TiO 2 nanotube surface in recent studies in which the scale of nanotube diameter was restricted under 100 nm. In this paper, a series of highly ordered TiO 2 nanotube arrays with larger diameters ranging from 150 nm to 470 nm were fabricated via high voltage anodization. The behaviors of MC3T3-E1 cells in response to the diameter-controlled TiO 2 nanotubes were investigated. A contrast between the trend of proliferation and the trend of cell elongation was observed. The highest cell elongation (nearly 10:1) and the lowest cell number were observed on the TiO 2 nanotube arrays with 150 nm diameter. While, the lowest cell elongation and highest cell number were achieved on the TiO 2 nanotube arrays with 470 nm diameter. Furthermore, the ALP activity peaked on the 150 nm diameter TiO 2 nanotube arrays and decreased dramatically with the increase of nanotube diameter. Thus a narrow range of diameter (100–200 nm) that could induce the greatest bone-forming activity is determined. It is expected that more delicate design of orthopedic implant with regional abduction of cell proliferation or bone forming could be achieved by controlling the diameter of TiO 2 nanotubes. - Highlights: • Improved anodization methods leading to more ordered large diameter TiO 2 nanotubes • Significantly enhanced ALP activity was observed on 150 nm diameter TiO 2 nanotubes. • The highest cell density was observed on 470 nm diameter TiO 2 nanotube arrays. • Similar cell response was observed on the amorphous and anatase phased nanotube surface

  9. Failure Diameter Resolution Study

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-19

    Previously the SURFplus reactive burn model was calibrated for the TATB based explosive PBX 9502. The calibration was based on fitting Pop plot data, the failure diameter and the limiting detonation speed, and curvature effect data for small curvature. The model failure diameter is determined utilizing 2-D simulations of an unconfined rate stick to find the minimum diameter for which a detonation wave propagates. Here we examine the effect of mesh resolution on an unconfined rate stick with a diameter (10mm) slightly greater than the measured failure diameter (8 to 9 mm).

  10. Incidence and Potential Mechanism(s) of Post-Procedural Rise of Cardiac Biomarker in Patients With Coronary Artery Narrowing After Implantation of an Everolimus-Eluting Bioresorbable Vascular Scaffold or Everolimus-Eluting Metallic Stent

    DEFF Research Database (Denmark)

    Ishibashi, Yuki; Muramatsu, Takashi; Nakatani, Shimpei

    2015-01-01

    OBJECTIVES: This study sought to evaluate the mechanism of post-procedural cardiac biomarker (CB) rise following device implantation. BACKGROUND: A fully bioresorbable Absorb scaffold, compared with everolimus-eluting metallic stents (EES), might be associated with a higher incidence...

  11. Narrow dibaryon resonances

    International Nuclear Information System (INIS)

    Kajdalov, A.B.

    1986-01-01

    Experimental data on np interactions indicating to existence of narrow resonances in pp-system are discussed. Possible theoretical interpretations of these resonances are given. Experimental characteristics of the dibaryon resonances with isospin I=2 are considered

  12. Clinical and radiological investigations of mandibular overdentures supported by conventional or mini-dental implants: A 2-year prospective follow-up study.

    Science.gov (United States)

    Temizel, Sonay; Heinemann, Friedhelm; Dirk, Cornelius; Bourauel, Christoph; Hasan, Istabrak

    2017-02-01

    Conventional dental implants are not applicable in the mandibular interforaminal region if bone volume is limited. Mini-dental implants offer an alternative means of supporting mandibular overdentures in a narrow residual ridge, without additional surgery. The purpose of this nonrandomized clinical trial was to compare the ability of mini-dental implants with that of conventional dental implants in supporting mandibular overdentures during a 2-year clinical follow-up. Bone quality, bone resorption, implant stability, and oral health were assessed radiographically. A total of 32 participants with edentulism were included. Twenty-two participants (99 implants) received 4 to 5 mini-dental implants (diameter: 1.8-2.4 mm; length: 13-15 mm, study group), and 10 participants (35 implants) received 2 to 4 conventional dental implants (diameter: 3.3-3.7 mm; length: 11-13 mm, control group). The selection of the participants in the study or control group was based on the available bone volume in the mandible. The selection was not randomized. The density of cortical bone thickness was measured in Hounsfield units (HU) from computed tomography data, and patients were followed for 2 years. The participants were examined 3, 6, 12, and 24 months after surgery. Primary stability immediately after the insertion of dental implants (Periotest), secondary stability 6 months after implantation, modified plaque, bleeding on probing indices, and probing depth were measured and analyzed statistically (α=.05). The mean HU value 6 months after implantation in the participants who received mini-dental implants was significantly (P=.035) higher (1250 HU) than that in the participants who received conventional dental implants (1100 HU). The probing depths around the conventional dental implants (1.6 and 1.8 mm, respectively) were significantly higher than those around the mini-dental implants (1.3 and 1.2 mm, respectively) 12 and 24 months after surgery, respectively (Pdental implants were

  13. Jihadism, Narrow and Wide

    DEFF Research Database (Denmark)

    Sedgwick, Mark

    2015-01-01

    The term “jihadism” is popular, but difficult. It has narrow senses, which are generally valuable, and wide senses, which may be misleading. This article looks at the derivation and use of “jihadism” and of related terms, at definitions provided by a number of leading scholars, and at media usage....... It distinguishes two main groups of scholarly definitions, some careful and narrow, and some appearing to match loose media usage. However, it shows that even these scholarly definitions actually make important distinctions between jihadism and associated political and theological ideology. The article closes...

  14. Correlates of Narrow Bracketing

    DEFF Research Database (Denmark)

    Koch, Alexander; Nafziger, Julia

    We examine whether different phenomena of narrow bracketing can be traced back to some common characteristic and whether and how different phenomena are related. We find that making dominated lottery choices or ignoring the endowment when making risky choices are related phenomena and are both as...

  15. Damage and in-situ annealing during ion implantation

    International Nuclear Information System (INIS)

    Sadana, D.K.; Washburn, J.; Byrne, P.F.; Cheung, N.W.

    1982-11-01

    Formation of amorphous (α) layers in Si during ion implantation in the energy range 100 keV-11 MeV and temperature range liquid nitrogen (LN)-100 0 C has been investigated. Cross-sectional transmission electron microscopy (XTEM) shows that buried amorphous layers can be created for both room temperature (RT) and LN temperature implants, with a wider 100 percent amorphous region for the LN cooled case. The relative narrowing of the α layer during RT implantation is attributed to in-situ annealing. Implantation to the same fluence at temperatures above 100 0 C does not produce α layers. To further investigate in situ annealing effects, specimens already containing buried α layers were further irradiated with ion beams in the temperature range RT-400 0 C. It was found that isolated small α zones (less than or equal to 50 diameter) embedded in the crystalline matrix near the two α/c interfaces dissolved into the crystal but the thickness of the 100 percent α layer was not appreciably affected by further implantation at 200 0 C. A model for in situ annealing during implantation is presented

  16. Value of Combining Left Atrial Diameter and Amino-terminal Pro-brain Natriuretic Peptide to the CHA2DS2-VASc Score for Predicting Stroke and Death in Patients with Sick Sinus Syndrome after Pacemaker Implantation

    Directory of Open Access Journals (Sweden)

    Bin-Feng Mo

    2017-01-01

    Conclusions: CHA2DS2-VASc score is valuable for predicting stroke and death risk in patients with SSS after pacemaker implantation. The addition of LAD and NT-proBNP to the CHA2DS2-VASc score improved its predictive power for stroke and death, respectively, in this patient cohort. Future prospective studies are warranted to validate the benefit of adding LAD and NT-proBNP to the CHA2DS2-VASc score for predicting stroke and death risk in non-AF populations.

  17. New stimulation method with the function of narrowing and moving the stimulated region for cochlear implants. Its evaluation by the animal experiment and the numerical analysis; Jinko naiji no tame no shigeki bui no seneika to ido kino wo motta shigeki hoshiki. Suchi kaiseki to dobutsu jikken ni yoru hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Miyoshi, S.; Sakajiri, M.; Ifukube, T.; Matsushima, J. [Hokkaido University, Sapporo (Japan)

    1998-02-01

    The electrical stimulation of the auditory nerve can elicit auditory sensations in the subjects with sensorineural deafness. Each stimulating electrode of an electrode array of the multi-channel cochlear implants may stimulate a distinct neural population. However, a great deal of current spreads from each electrode throughout a lymph because of the high electrical conductivity of the lymph liquid. This phenomenon causes the transmitted information to be reduce due to channel interactions. Even if the number of electrodes is increased, the transmitted information will be limited because of current spread. We have proposed the Tripolar Electrode Stimulation Method (TESM) which may succeed in narrowing the stimulation region and continuously moving the stimulation site for the cochlear implants. We evaluate whether or not TESM works according to a theory which is based on the numerical analysis using the auditory nerve fiber model consisted of unmyelinated and myelinated segments. In this simulation, the neural site and the am of the excited fibers are compared with the compound action potentials which we obtained through animal experiments. As a result, based on the numerical analysis using this model, it is also proved that the anodal/cathodal threshold stimulation current ratio increases by decreasing unmyelinated segment between the inner hair cell and the habenula perforate. Also by comparing the result of the numerical analysis with that of the animal experiment, It is suggested that an effect of the unmyelinated segment is not significant. Based on their results mentioned above, we succeed in narrowing a Stimulation region by controlling the am of the currents emitted from the electrodes on both sides. Also we succeed in continuously moving a stimulation site by changing the ratio of the currents emitted from the electrodes on both sides. 11 refs., 14 figs., 1 tab.

  18. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.

    Science.gov (United States)

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R

    2017-02-01

    The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; Pstent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels 15 mm length. © 2016 John Wiley & Sons Ltd.

  19. Failure analysis of fractured dental zirconia implants.

    Science.gov (United States)

    Gahlert, M; Burtscher, D; Grunert, I; Kniha, H; Steinhauser, E

    2012-03-01

    The purpose of the present study was the macroscopic and microscopic failure analysis of fractured zirconia dental implants. Thirteen fractured one-piece zirconia implants (Z-Look3) out of 170 inserted implants with an average in situ period of 36.75±5.34 months (range from 20 to 56 months, median 38 months) were prepared for macroscopic and microscopic (scanning electron microscopy [SEM]) failure analysis. These 170 implants were inserted in 79 patients. The patient histories were compared with fracture incidences to identify the reasons for the failure of the implants. Twelve of these fractured implants had a diameter of 3.25 mm and one implant had a diameter of 4 mm. All fractured implants were located in the anterior side of the maxilla and mandibula. The patient with the fracture of the 4 mm diameter implant was adversely affected by strong bruxism. By failure analysis (SEM), it could be demonstrated that in all cases, mechanical overloading caused the fracture of the implants. Inhomogeneities and internal defects of the ceramic material could be excluded, but notches and scratches due to sandblasting of the surface led to local stress concentrations that led to the mentioned mechanical overloading by bending loads. The present study identified a fracture rate of nearly 10% within a follow-up period of 36.75 months after prosthetic loading. Ninety-two per cent of the fractured implants were so-called diameter reduced implants (diameter 3.25 mm). These diameter reduced implants cannot be recommended for further clinical use. Improvement of the ceramic material and modification of the implant geometry has to be carried out to reduce the failure rate of small-sized ceramic implants. Nevertheless, due to the lack of appropriate laboratory testing, only clinical studies will demonstrate clearly whether and how far the failure rate can be reduced. © 2011 John Wiley & Sons A/S.

  20. [Fracture of implant abutment screws and removal of a remaining screw piece

    NARCIS (Netherlands)

    Broeke, S.M. van den; Baat, C. de

    2008-01-01

    Fracture of the implant abutment screws is a complication which can render an implant useless. The prevalence of abutment screw fracture does not exceed 2.5% after 10 years. Causes are loosening of implant abutment screw, too few, too short or too narrow implants, implants not inserted perpendicular

  1. Puente Verrazano-Narrows

    Directory of Open Access Journals (Sweden)

    Ammann, -

    1964-05-01

    Full Text Available This outstanding suspension bridge underwent a long process of preparation, and it has finally served to solve a most urgent and intense problem of communication between Brooking and Staten Island. This bridge represents an exceptional engineering achievement firstly because of the 1,298 m span between its two towers, and the two side spans of 370 m; secondly due to the vast amounts of materials involved in its construction. The suspended deck will have two directions of traffic, each consisting of six lanes, the two directions separated by a central division. The anchorage and foundations reach down to a depth of 50 m. The towers supporting the main suspension cables are 210 m high above the mean sea level. Their prefabricated external metal shell contain inside a complex system of thousands of metal cells. The deck hangs from four main suspension cables, each 90 cm in diameter. Hanger cables, each 55 cm in diameter, support the deck. The cable spinning over the main towers was a difficult and highly complicated operation. Details of this are given in the accompanying diagrams. Simultaneous with the construction of the bridge, the main access roads to it have been improved and altered, in order to chanalise the heavy traffic more effectively towards it. The whole project, including the construction of the bridge and alterations to the approaches, has amounted to a total cost of the order of 400 million dollars. The safety of the personnel working on this project has been very carefully studied. Ellaborate arrangements are being rigidly enforced for the protection of human lives. It is hoped that this huge project will be completed within the present year.Esta destacada obra, suspendida, realizada por la Triborough Bridge and Tunnel Authority, cuenta con una larga gestación que por fin culminó en una realidad y, con ella, a dar solución a una angustiosa situación que el tráfico rodado venía creando progresivamente con sus innumerables

  2. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  3. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  4. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  5. Flooding correlations in narrow channel

    International Nuclear Information System (INIS)

    Kim, S. H.; Baek, W. P.; Chang, S. H.

    1999-01-01

    Heat transfer in narrow gap is considered as important phenomena in severe accidents in nuclear power plants. Also in heat removal of electric chip. Critical heat flux(CHF) in narrow gap limits the maximum heat transfer rate in narrow channel. In case of closed bottom channel, flooding limited CHF occurrence is observed. Flooding correlations will be helpful to predict the CHF in closed bottom channel. In present study, flooding data for narrow channel geometry were collected and the work to recognize the effect of the span, w and gap size, s were performed. And new flooding correlations were suggested for high-aspect-ratio geometry. Also, flooding correlation was applied to flooding limited CHF data

  6. Narrow n anti n resonances

    International Nuclear Information System (INIS)

    Bogdanova, L.N.; Dalkarov, O.D.; Kerbikov, B.O.; Shapiro, I.S.

    1975-01-01

    The present status of the problem of quasinuclear states in systems of nucleons and antinucleons is reviewed. The theoretical predictions are compared with experimental data on narrow meson resonances near N anti N threshold which appeared in 1971-74

  7. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...

  8. Cervical spinal canal narrowing and cervical neurologi-cal injuries

    Directory of Open Access Journals (Sweden)

    ZHANG Ling

    2012-04-01

    Full Text Available 【Abstract】Cervical spinal canal narrowing can lead to injury of the spinal cord and neurological symptoms in-cluding neck pain, headache, weakness and parasthesisas. According to previous and recent clinical researches, we investigated the geometric parameters of normal cervical spinal canal including the sagittal and transverse diameters as well as Torg ratio. The mean sagittal diameter of cervical spinal canal at C 1 to C 7 ranges from 15.33 mm to 20.46 mm, the mean transverse diameter at the same levels ranges from 24.45 mm to 27.00 mm and the mean value of Torg ratio is 0.96. With respect to narrow cervical spinal canal, the following charaterstics are found: firstly, extension of the cervical spine results in statistically significant stenosis as compared with the flexed or neutral positions; secondly, females sustain cervical spinal canal narrowing more easily than males; finally, the consistent narrowest cervical canal level is at C 4 for all ethnicity, but there is a slight variation in the sagittal diameter of cervical spinal stenosis (≤14 mm in Whites, ≤ 12 mm in Japanese, ≤13.7 mm in Chinese. Narrow sagittal cervical canal diameter brings about an increased risk of neurological injuries in traumatic, degenerative and inflam-matory conditions and is related with extension of cervical spine, gender, as well as ethnicity. It is hoped that this re-view will be helpful in diagnosing spinal cord and neuro-logical injuries with the geometric parameters of cervical spine in the future. Key words: Spinal cord injuries; Spinal stenosis; Trauma, nervous system

  9. Fission tracks diameters in glasses

    International Nuclear Information System (INIS)

    Garzon Ruiperez, L.; Veiguela, J.

    1974-01-01

    Standard glass microscope slides have been irradiated with fission fragments from the uranium. The etching track conditions have been the same for the series, having changed the etching time only for each specimen. For each glass, a minimum of 250 measurements of the tracks diameters have been made, the distributions of which are the bimodal type. Diameters-etching dependence with time is roughly lineal. Energy determinations have been made with the help of the diameters-energy relations. The calculated values agree very well with the know ones. (author) [es

  10. Diameter 2 properties and convexity

    Czech Academy of Sciences Publication Activity Database

    Abrahamsen, T. A.; Hájek, Petr Pavel; Nygaard, O.; Talponen, J.; Troyanski, S.

    2016-01-01

    Roč. 232, č. 3 (2016), s. 227-242 ISSN 0039-3223 R&D Projects: GA ČR GA16-07378S Institutional support: RVO:67985840 Keywords : diameter 2 property * midpoint locally uniformly rotund * Daugavet property Subject RIV: BA - General Mathematics Impact factor: 0.535, year: 2016 https://www.impan.pl/pl/wydawnictwa/czasopisma-i-serie-wydawnicze/studia- mathematica /all/232/3/91534/diameter-2-properties-and-convexity

  11. [Researches on biomechanics of micro-implant-bone interface and optimum design of micro implant's neck].

    Science.gov (United States)

    Deng, Feng; Zhang, Lei; Zhang, Yi; Song, Jin-lin; Fan, Yuboa

    2007-07-01

    To compare and analyze the stress distribution at the micro-implant-bone interface based on the different micro-implant-bone conditioned under orthodontic load, and to optimize the design of micro implant's neck. An adult skull with all tooth was scanned by spiral CT, and the data were imported into computer for three-dimensional reconstruction with software Mimics 9.0. The three dimensional finite element models of three micro-implant-bone interfaces(initial stability, full osseointegration and fibrous integration) were analyzed by finite element analysis software ABAQUS6.5. The primary stress distributions of different micro-implant-bone conditions were evaluated when 2N force was loaded. Then the diameter less than 1.5 mm of the micro implant's neck was added with 0.2 mm, to compare the stress distribution of the modified micro-implant-bone interface with traditional type. The stress mostly concentrated on the neck of micro implant and the full osseointegration interface in all models showed the lowest strain level. Compared with the traditional type, the increasing diameter neck of the micro implant obviously decreased the stress level in all the three conditions. The micro-implant-bone interface and the diameter of micro implant's neck both are the important influence factors to the stress distribution of micro implant.

  12. The Relationship amongst Intervertebral Disc Vertical Diameter, Lateral Foramen Diameter and Nerve Root Impingement in Lumbar Vertebra

    Directory of Open Access Journals (Sweden)

    Yusof MI

    2018-03-01

    Full Text Available Introduction: The vertical diameter of the foramen is dependent upon the vertical diameter of the corresponding intervertebral disc. A decrease in disc vertical diameter has direct anatomic consequences to the foraminal diameter and area available for the nerve root passing through it. This study is to establish the relationship amongst the intervertebral disc vertical diameter, lateral foramen diameters and nerve root compression in the lumbar vertebra. Materials and Methods: Measurements of the study parameters were performed using sagittal MRI images. The parameters studied were: intervertebral disc vertical diameter (DVD, foraminal vertical diameter (FVD, foraminal transverse diameter (FTD and nerve root diameter (NRD of both sides. The relationship between the measured parameters were then analyzed. Results: A total of 62 MRI images were available for this study. Statistical analysis showed moderate to strong correlation between DVD and FVD at all the lumbar levels except at left L23 and L5S1 and right L3L4 and L4L5. Correlation between DVD and FTD were not significant at all lumbar levels. Regression analysis showed that a decrease of 1mm of DVD was associated with 1.3, 1.7, 3.3, 3.3 and 1.3mm reduction of FVD at L1L2, L2L3, L3L4, L4L5 and L5S1 respectively. Conclusion: Reduction of DVD was associated with reduction of FVD. However, FVD was relatively wide for the nerve root even with complete loss of DVD. FTD was much narrower than the FVD making it more likely to cause nerve root compression at the exit foramina. These anatomical details should be given consideration in treating patients with lateral canal stenosis.

  13. QSOs with narrow emission lines

    International Nuclear Information System (INIS)

    Baldwin, J.A.; Mcmahon, R.; Hazard, C.; Williams, R.E.

    1988-01-01

    Observations of two new high-redshift, narrow-lined QSOs (NLQSOs) are presented and discussed together with observations of similar objects reported in the literature. Gravitational lensing is ruled out as a possible means of amplifying the luminosity for one of these objects. It is found that the NLQSOs have broad bases on their emission lines as well as the prominent narrow cores which define this class. Thus, these are not pole-on QSOs. The FWHM of the emission lines fits onto the smoothly falling tail of the lower end of the line-width distribution for complete QSO samples. The equivalent widths of the combined broad and narrow components of the lines are normal for QSOs of the luminosity range under study. However, the NLQSOs do show ionization differences from broader-lined QSOs; most significant, the semiforbidden C III/C IV intensity ratio is unusually low. The N/C abundance ratio in these objects is found to be normal; the Al/C abundance ratio may be quite high. 38 references

  14. Cochlear Implants

    Science.gov (United States)

    ... implant, including: • How long a person has been deaf, •The number of surviving auditory nerve fibers, and • ... Implant, Severe Sensoryneurial Hearing Loss Get Involved Professional Development Practice Management ENT Careers Marketplace Privacy Policy Terms ...

  15. Diameter sensitive effect in singlewalled carbon nanotubes upon acid treatment

    International Nuclear Information System (INIS)

    Costa, S.; Borowiak-Palen, E.

    2009-01-01

    Singlewalled carbon nanotubes (SWCNT) exhibit very unique properties. As an electronic system they undergo amphoteric doping effects (n-type and p-type) which can be reversed. These processes affect the optical and vibronic properties of the carbon nanotubes. The most common and widely used procedure which changes the properties of the SWCNT is acid treatment applied as a purification procedure. This effect has been widely studied but not fully understood so far. Here, we present a study, in which a diameter sensitive effect has been observed. Therefore, two kinds of SWCNT samples have been studied: (i) produced via chemical vapour deposition with a broad diameter distribution, and (ii) synthesised by the laser ablation technique which is commonly known to result in narrow diameter distribution bulk SWCNT samples. Resonance Raman spectroscopy, optical absorption spectroscopy, and Fourier transform middle-infrared spectroscopy have been applied for the characterisation of the samples.

  16. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    configuration and remote handling options. Current implanter capacities are around 60 wafers/hr, each wafer being 150mm in diameter with a typical doping level of 3 x 10 15 cm -r 2

  17. Macro design morphology of endosseous dental implants.

    Science.gov (United States)

    Sahiwal, Indira G; Woody, Ronald D; Benson, Byron W; Guillen, Guillermo E

    2002-05-01

    The identification of dental implant bodies in patients without available records is a considerable problem due to increased patient mobility and to the large number of implant systems with different designs. The purpose of this study was to document the designs of selected implants to help clinicians identify these implants from their radiographic images. More than 50 implant manufacturers were contacted and asked to provide implants with dimensions as close as possible to 3.75 mm (diameter) x 10 mm (length). Forty-four implants were donated, separated into threaded and non-threaded categories, and further sorted into tapered and non-tapered categories. The implants were examined visually, and features on the entire circumference and length of each implant were recorded and categorized as coronal, midbody, or apical. A series of tables describe the 44 implants according to coronal, midbody, and apical features. The results of this project offer dentists basic knowledge of the design of selected dental implants. Such knowledge can aid the radiographic identification of these implants.

  18. Tribological properties of nitrogen implanted and boron implanted steels

    International Nuclear Information System (INIS)

    Kern, K.T.

    1996-01-01

    Samples of a steel with high chrome content was implanted separately with 75 keV nitrogen ions and with 75 keV boron ions. Implanted doses of each ion species were 2-, 4-, and 8 x 10 17 /cm 2 . Retained doses were measured using resonant non-Rutherford Backscattering Spectrometry. Tribological properties were determined using a pin-on-disk test with a 6-mm diameter ruby pin with a velocity of 0.94 m/min. Testing was done at 10% humidity with a load of 377 g. Wear rate and coefficient of friction were determined from these tests. While reduction in the wear rate for nitrogen implanted materials was observed, greater reduction (more than an order of magnitude) was observed for boron implanted materials. In addition, reduction in the coefficient of friction for high-dose boron implanted materials was observed. Nano-indentation revealed a hardened layer near the surface of the material. Results from grazing incidence x-ray diffraction suggest the formation of Fe 2 N and Fe 3 N in the nitrogen implanted materials and Fe 3 B in the boron implanted materials. Results from transmission electron microscopy will be presented

  19. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  20. Diameter Tuning of Single-Walled Carbon Nanotubes by Diffusion Plasma CVD

    Directory of Open Access Journals (Sweden)

    Toshiaki Kato

    2011-01-01

    Full Text Available We have realized a diameter tuning of single-walled carbon nanotubes (SWNTs by adjusting process gas pressures with plasma chemical vapor deposition (CVD. Detailed photoluminescence measurements reveal that the diameter distribution of SWNTs clearly shifts to a large-diameter region with an increase in the pressure during plasma CVD, which is also confirmed by Raman scattering spectroscopy. Based on the systematical investigation, it is found that the main diameter of SWNTs is determined by the pressure during the heating in an atmosphere of hydrogen and the diameter distribution is narrowed by adjusting the pressure during the plasma generation. Our results could contribute to an application of SWNTs to high-performance thin-film transistors, which requires the diameter-controlled semiconductor-rich SWNTs.

  1. Prediction of bubble detachment diameter in flow boiling based on force analysis

    International Nuclear Information System (INIS)

    Chen Deqi; Pan Liangming; Ren Song

    2012-01-01

    Highlights: ► All the forces acting on the growing bubbles are taken into account in the model. ► The bubble contact diameter has significant effect on bubble detachment. ► Bubble growth force and surface tension are more significant in narrow channel. ► A good agreement between the predicted and the measured results is achieved. - Abstract: Bubble detachment diameter is one of the key parameters in the study of bubble dynamics and boiling heat transfer, and it is hard to be measured in a boiling system. In order to predict the bubble detachment diameter, a theoretical model is proposed based on forces analysis in this paper. All the forces acting on a bubble are taken into account to establish a model for different flow boiling configurations, including narrow and conventional channels, upward, downward and horizontal flows. A correlation of bubble contact circle diameter is adopted in this study, and it is found that the bubble contact circle diameter has significant effect on bubble detachment. A new correlation taking the bubble contact circle diameter into account for the evaluation of bubble growth force is proposed in this study, and it is found that the bubble growth force and surface tension force are more significant in narrow channel when comparing with that in conventional channel. A visual experiment was carried out in order to verify present model; and the experimental data from published literature are used also. A good agreement between predicted and measured results is achieved.

  2. Influence of different implant materials on the primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po

    2012-12-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.

  3. Influence of different implant materials on the primary stability of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Chin-Yun Pan

    2012-12-01

    Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.

  4. The effects of simulated bone loss on the implant-abutment assembly and likelihood of fracture: an in vitro study.

    Science.gov (United States)

    Manzoor, Behzad; Suleiman, Mahmood; Palmer, Richard M

    2013-01-01

    The crestal bone level around a dental implant may influence its strength characteristics by offering protection against mechanical failures. Therefore, the present study investigated the effect of simulated bone loss on modes, loads, and cycles to failure in an in vitro model. Different amounts of bone loss were simulated: 0, 1.5, 3.0, and 4.5 mm from the implant head. Forty narrow-diameter (3.0-mm) implant-abutment assemblies were tested using compressive bending and cyclic fatigue testing. Weibull and accelerated life testing analysis were used to assess reliability and functional life. Statistical analyses were performed using the Fisher-Exact test and the Spearman ranked correlation. Compressive bending tests showed that the level of bone loss influenced the load-bearing capacity of implant-abutment assemblies. Fatigue testing showed that the modes, loads, and cycles to failure had a statistically significant relationship with the level of bone loss. All 16 samples with bone loss of 3.0 mm or more experienced horizontal implant body fractures. In contrast, 14 of 16 samples with 0 and 1.5 mm of bone loss showed abutment and screw fractures. Weibull and accelerated life testing analysis indicated a two-group distribution: the 0- and 1.5-mm bone loss samples had better functional life and reliability than the 3.0- and 4.5-mm samples. Progressive bone loss had a significant effect on modes, loads, and cycles to failure. In addition, bone loss influenced the functional life and reliability of the implant-abutment assemblies. Maintaining crestal bone levels is important in ensuring biomechanical sustainability and predictable long-term function of dental implant assemblies.

  5. Narrow gap electronegative capacitive discharges

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, E.; Lieberman, M. A.; Lichtenberg, A. J. [Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720 (United States)

    2013-10-15

    Narrow gap electronegative (EN) capacitive discharges are widely used in industry and have unique features not found in conventional discharges. In this paper, plasma parameters are determined over a range of decreasing gap length L from values for which an electropositive (EP) edge exists (2-region case) to smaller L-values for which the EN region connects directly to the sheath (1-region case). Parametric studies are performed at applied voltage V{sub rf}=500 V for pressures of 10, 25, 50, and 100 mTorr, and additionally at 50 mTorr for 1000 and 2000 V. Numerical results are given for a parallel plate oxygen discharge using a planar 1D3v (1 spatial dimension, 3 velocity components) particle-in-cell (PIC) code. New interesting phenomena are found for the case in which an EP edge does not exist. This 1-region case has not previously been investigated in detail, either numerically or analytically. In particular, attachment in the sheaths is important, and the central electron density n{sub e0} is depressed below the density n{sub esh} at the sheath edge. The sheath oscillations also extend into the EN core, creating an edge region lying within the sheath and not characterized by the standard diffusion in an EN plasma. An analytical model is developed using minimal inputs from the PIC results, and compared to the PIC results for a base case at V{sub rf}=500 V and 50 mTorr, showing good agreement. Selected comparisons are made at the other voltages and pressures. A self-consistent model is also developed and compared to the PIC results, giving reasonable agreement.

  6. Finite Element Analysis of Bone Stress for Miniscrew Implant Proximal to Root Under Occlusal Force and Implant Loading.

    Science.gov (United States)

    Shan, Li-Hua; Guo, Na; Zhou, Guan-jun; Qie, Hui; Li, Chen-Xi; Lu, Lin

    2015-10-01

    Because of the narrow interradicular spaces and varying oral anatomies of individual patients, there is a very high risk of root proximity during the mini implants inserting. The authors hypothesized that normal occlusal loading and implant loading affected the stability of miniscrew implants placed in proximity or contact with the adjacent root. The authors implemented finite element analysis (FEA) to examine the effectiveness of root proximity and root contact. Stress distribution in the bone was assessed at different degrees of root proximity by generating 4 finite element models: the implant touches the root surface, the implant was embedded in the periodontal membrane, the implant touches the periodontal surface, and the implant touches nothing. Finite element analysis was then carried out with simulations of 2 loading conditions for each model: condition A, involving only tooth loading and condition B, involving both tooth and implant loading. Under loading condition A, the maximum stress on the bone for the implant touching the root was the distinctly higher than that for the other models. For loading condition B, peak stress areas for the implant touching the root were the area around the neck of the mini implant and the point of the mini implant touches the root. The results of this study suggest that normal occlusal loading and implant loading contribute to the instability of the mini implant when the mini implant touches the root.

  7. Review on two-phase flow instabilities in narrow spaces

    International Nuclear Information System (INIS)

    Tadrist, L.

    2007-01-01

    Instabilities in two-phase flow have been studied since the 1950s. These phenomena may appear in power generation and heat transfer systems where two-phase flow is involved. Because of thermal management in small size systems, micro-fluidics plays an important role. Typical processes must be considered when the channel hydraulic diameter becomes very small. In this paper, a brief review of two-phase flow instabilities encountered in channels having hydraulic diameters greater than 10 mm are presented. The main instability types are discussed according to the existing experimental results and models. The second part of the paper examines two-phase flow instabilities in narrow spaces. Pool and flow boiling cases are considered. Experiments as well as theoretical models existing in the literature are examined. It was found that several experimental works evidenced these instabilities meanwhile only limited theoretical developments exist in the literature. In the last part of the paper an interpretation of the two-phase flow instabilities linked to narrow spaces are presented. This approach is based on characteristic time scales of the two-phase flow and bubble growth in the capillaries

  8. Photonic bandgap narrowing in conical hollow core Bragg fibers

    Energy Technology Data Exchange (ETDEWEB)

    Ozturk, Fahri Emre; Yildirim, Adem; Kanik, Mehmet [UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara (Turkey); Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara (Turkey); Bayindir, Mehmet, E-mail: bayindir@nano.org.tr [UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara (Turkey); Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara (Turkey); Department of Physics, Bilkent University, 06800 Ankara (Turkey)

    2014-08-18

    We report the photonic bandgap engineering of Bragg fibers by controlling the thickness profile of the fiber during the thermal drawing. Conical hollow core Bragg fibers were produced by thermal drawing under a rapidly alternating load, which was applied by introducing steep changes to the fiber drawing speed. In conventional cylindrical Bragg fibers, light is guided by omnidirectional reflections from interior dielectric mirrors with a single quarter wave stack period. In conical fibers, the diameter reduction introduced a gradient of the quarter wave stack period along the length of the fiber. Therefore, the light guided within the fiber encountered slightly smaller dielectric layer thicknesses at each reflection, resulting in a progressive blueshift of the reflectance spectrum. As the reflectance spectrum shifts, longer wavelengths of the initial bandgap cease to be omnidirectionally reflected and exit through the cladding, which narrows the photonic bandgap. A narrow transmission bandwidth is particularly desirable in hollow waveguide mid-infrared sensing schemes, where broadband light is coupled to the fiber and the analyte vapor is introduced into the hollow core to measure infrared absorption. We carried out sensing simulations using the absorption spectrum of isopropyl alcohol vapor to demonstrate the importance of narrow bandgap fibers in chemical sensing applications.

  9. Implant supported overdentures--the Copenhagen experience

    DEFF Research Database (Denmark)

    Gotfredsen, K

    1997-01-01

    OBJECTIVES: To evaluate the functional and biological effect of implant-supported overdenture treatment in the lower jaw. METHODS AND MATERIALS: Thirty-two patients were consecutively treated with Astra Tech implants in the lower jaw for retaining overdentures. All implants had a diameter of 3.5 mm...... and all but two of the implants were longer than 10 mm. For the implant supported overdentures two methods of attachment were used, a bar or a ball. RESULTS: One of 69 fixtures was lost during the 4-5 year observation period. The mean bone loss for all fixtures was less than 0.2 mm per year. Complications...... quality and quantity is sufficient, two implants can support an overdenture in the lower jaw, providing prosthesis which functions well....

  10. Quantitative measurement of changes in retinal vessel diameter in ocular fundus images

    DEFF Research Database (Denmark)

    Pedersen, Lars; Grunkin, Michael; Ersbøll, Bjarne Kjær

    2000-01-01

    The change in diameter of retinal vessels as a function of increasing distance to the optic disc is believed to be indicative of the risk level of various vascular diseases such as generalised arteriosclerosis and Diabetes Mellitus. In particular, focal arteriolar narrowing (FAN) is considered re...

  11. A method for calculating equivalent diameter of fiber in self-compacting fiber reinforced concrete

    NARCIS (Netherlands)

    Yu, R.; Spiesz, P.R.; Brouwers, H.J.H.; Fischer, H.-B.; Bode, K.-A.; Beuthan, C.

    2012-01-01

    This paper presents a method for calculating the equivalent diameter of fiber in self-compacting fiber reinforced concrete (SCFRC). The key idea is to utilize a small amount of particles with a narrow particle size distribution to replace the fibers by the same volume, without causing any obvious

  12. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Carmustine Implant

    Science.gov (United States)

    ... works by slowing or stopping the growth of cancer cells in your body. ... are pregnant, plan to become pregnant, or are breast-feeding. If you become pregnant while receiving carmustine implant, call your doctor. Carmustine may harm the fetus.

  14. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  15. Non-linear optical properties of SiO2 with synthesized by implantation copper nanoparticles

    International Nuclear Information System (INIS)

    Stepanov, A.L.; Olivares, J.; Requejo-Isidro, J.; Del Coso, R.; De Nalda, R.; Solis, J.; Afonso, C.N.; Hole, D.; Townsend, P.D.; Naudon, A.

    2001-01-01

    In recent years there has been a growing interest in composite dielectrics containing metal nanoparticles for their potential application in wave-guide integrated all-optical non-linear switching devices. In present work, low energy high current ion implantation (50 keV) in silica at a well controlled substrate temperature (20 0 C) at a dose of 8·10 16 ion/cm 2 has been used to produce novel composites containing a large concentration of spherical Cu clusters with an average diameter of 4 nm and a very narrow size distribution. A very large value for the third order optical susceptibility, χ (3) = 10 -7 esu, has been measured in the vicinity of the surface plasmon resonance by degenerate four wave mixing at 585 nm. This value is among the largest values ever reported for Cu nano composites. Additionally, the response time of the non-linearity has been found to be shorter than 2 ps. The superior non-linear optical response of these implants is discussed in terms of the implantation conditions

  16. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    The implantation and sputtering mechanisms which are relevant to ion bombardment of surfaces are described. These are: collision, thermal, electronic and photon-induced sputtering. 135 refs.; 36 figs.; 9 tabs

  17. Formation of extremely narrow metallic lines

    International Nuclear Information System (INIS)

    Harris, E.P.; Keyes, R.W.

    1979-01-01

    A method for forming metal lines, particularly lines which are superconductive, involves delineating a pattern on a thin metal film on a substrate by masking techniques, ion implanting the metal film to a desired depth, removing the mask and etching away the unimplanted portion of the metal film to leave the line whose width is equal to the implanted depth. (U.K.)

  18. Eustachian tube diameter: Is it associated with chronic otitis media development?

    Science.gov (United States)

    Paltura, Ceki; Can, Tuba Selçuk; Yilmaz, Behice Kaniye; Dinç, Mehmet Emre; Develioğlu, Ömer Necati; Külekçi, Mehmet

    To evaluate the effect of ET diameter on Chronic Otitis Media (COM) pathogenesis. Retrospective. Patients with unilateral COM disease are included in the study. The connection between fibrocartilaginous and osseous segments of the Eustachian Tube (ET) on axial Computed Tomography (CT) images was defined and the diameter of this segment is measured. The measurements were carried out bilaterally and statistically compared. 154 (76 (49%) male, 78 (51%) female patients were diagnosed with unilateral COM and included in the study. The mean diameter of ET was 1947mm (Std. deviation±0.5247) for healthy ears and 1788mm (Std. deviation±0.5306) for diseased ears. The statistical analysis showed a significantly narrow ET diameter in diseased ear side (p<0.01). The dysfunction or anatomical anomalies of ET are correlated with COM. Measuring of the bony diameter of ET during routine Temporal CT examination is recommended for our colleagues. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Improved Design Basis for Laterally Loaded Large Diameter Pile

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    of up-to-date facilities has been: Equipment for controlling centrifuge tests, data acquisition, preparation of test samples and equipment for and making of lateral load tests. The present research has been narrowed to investigate the static and cyclic behaviour of stiff piles with a diameter of 1-3 m...... in dry sand by use of centrifuge modelling and to compare the findings with the standard p-y curves. It has been chosen to apply piles with an embedment length of 6 to 10 times the diameter of the applied piles. The general static behaviour of monopiles in dry sand has based on centrifuge tests been...... with a capacity of 3.6 MW and placed at water depths beyond 25 m. Different foundation solutions have over the years been applied for offshore turbines, but monopiles are currently the most applied foundation type and are typically with a pile diameter of 4-6 m and applied up to a water depth of 25 m...

  20. Impact of implant design on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  1. The fracture strength by a torsion test at the implant-abutment interface.

    Science.gov (United States)

    Watanabe, Fumihiko; Hiroyasu, Kazuhiko; Ueda, Kazuhiko

    2015-12-01

    Fractured connections between implants and implant abutments or abutment screws are frequently encountered in a clinical setting. The purpose of this study was to investigate fracture strength using a torsion test at the interface between the implant and the abutment. Thirty screw-type implant with diameters of 3.3, 3.8, 4.3, 5.0, and 6.0 mm were submitted to a torsion test. Implants of each size were connected to abutments with abutment screws tightened to 20 N · cm. Mechanical stress was applied with a rotational speed of 3.6 °/min until fracture occurred, and maximum torque (fracture torque) and torsional yield strength were measured. The mean values were calculated and then compared using Tukey's test. The abutments were then removed, and the implant-abutment interfaces were examined using a scanning electron microscope (SEM). No significant differences in mean fracture torque were found among 3.3, 3.8, and 4.3 mm-diameter implants, but significant differences were found between these sizes and 5.0 and 6.0 mm-diameter implants (p abutment corresponding to the internal notches of the implant body had been destroyed. Smaller diameter implants demonstrated lower fracture torque and torsional yield strength than implants with larger diameters. In internal tube-in-tube connections, three abutment projections corresponding to rotation-prevention notches were destroyed in each implant.

  2. Diameter-speed relation of sprite streamers

    International Nuclear Information System (INIS)

    Kanmae, T; Stenbaek-Nielsen, H C; McHarg, M G; Haaland, R K

    2012-01-01

    Propagation and splitting of sprite streamers has been observed at high temporal and spatial resolution using two intensified high-speed CMOS cameras recording at 10 000 and 16 000 frames per second. Concurrent video recordings from a remote site provided data for triangulation allowing us to determine accurate altitude scales for the sprites. Diameters and speeds of the sprite streamers were measured from the high-speed images, and the diameters were scaled to the reduced diameters based on the triangulated locations. The sprite streamers with larger reduced diameter move faster than those with smaller diameter; the relation between the reduced diameter and speed is roughly linear. The reduced diameters at ≈65-70 km altitude are larger than streamer diameters measured at ground pressure in laboratory discharges indicating a deviation from the similarity law possibly due to the effects of the photoionization and an expansion of the streamer head along its propagation over a long distance. The reduced diameter and speed of the sprite streamers agree well with the diameter-velocity relation proposed by Naidis (2009 Phys. Rev. E 79 057401), and the peak electric field of the sprite streamers is estimated to be approximately 3-5 times the breakdown threshold field. (paper)

  3. Device Physics of Narrow Gap Semiconductors

    CERN Document Server

    Chu, Junhao

    2010-01-01

    Narrow gap semiconductors obey the general rules of semiconductor science, but often exhibit extreme features of these rules because of the same properties that produce their narrow gaps. Consequently these materials provide sensitive tests of theory, and the opportunity for the design of innovative devices. Narrow gap semiconductors are the most important materials for the preparation of advanced modern infrared systems. Device Physics of Narrow Gap Semiconductors offers descriptions of the materials science and device physics of these unique materials. Topics covered include impurities and defects, recombination mechanisms, surface and interface properties, and the properties of low dimensional systems for infrared applications. This book will help readers to understand not only the semiconductor physics and materials science, but also how they relate to advanced opto-electronic devices. The last chapter applies the understanding of device physics to photoconductive detectors, photovoltaic infrared detector...

  4. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  5. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  6. Carbon Fiber Biocompatibility for Implants

    Directory of Open Access Journals (Sweden)

    Richard Petersen

    2016-01-01

    Full Text Available Carbon fibers have multiple potential advantages in developing high-strength biomaterials with a density close to bone for better stress transfer and electrical properties that enhance tissue formation. As a breakthrough example in biomaterials, a 1.5 mm diameter bisphenol-epoxy/carbon-fiber-reinforced composite rod was compared for two weeks in a rat tibia model with a similar 1.5 mm diameter titanium-6-4 alloy screw manufactured to retain bone implants. Results showed that carbon-fiber-reinforced composite stimulated osseointegration inside the tibia bone marrow measured as percent bone area (PBA to a great extent when compared to the titanium-6-4 alloy at statistically significant levels. PBA increased significantly with the carbon-fiber composite over the titanium-6-4 alloy for distances from the implant surfaces of 0.1 mm at 77.7% vs. 19.3% (p < 10−8 and 0.8 mm at 41.6% vs. 19.5% (p < 10−4, respectively. The review focuses on carbon fiber properties that increased PBA for enhanced implant osseointegration. Carbon fibers acting as polymer coated electrically conducting micro-biocircuits appear to provide a biocompatible semi-antioxidant property to remove damaging electron free radicals from the surrounding implant surface. Further, carbon fibers by removing excess electrons produced from the cellular mitochondrial electron transport chain during periods of hypoxia perhaps stimulate bone cell recruitment by free-radical chemotactic influences. In addition, well-studied bioorganic cell actin carbon fiber growth would appear to interface in close contact with the carbon-fiber-reinforced composite implant. Resulting subsequent actin carbon fiber/implant carbon fiber contacts then could help in discharging the electron biological overloads through electrochemical gradients to lower negative charges and lower concentration.

  7. Potential Bone to Implant Contact Area of Short Versus Standard Implants: An In Vitro Micro-Computed Tomography Analysis.

    Science.gov (United States)

    Quaranta, Alessandro; DʼIsidoro, Orlando; Bambini, Fabrizio; Putignano, Angelo

    2016-02-01

    To compare the available potential bone-implant contact (PBIC) area of standard and short dental implants by micro-computed tomography (μCT) assessment. Three short implants with different diameters (4.5 × 6 mm, 4.1 × 7 mm, and 4.1 × 6 mm) and 2 standard implants (3.5 × 10 mm and 3.3 × 9 mm) with diverse design and surface features were scanned with μCT. Cross-sectional images were obtained. Image data were manually processed to find the plane that corresponds to the most coronal contact point between the crestal bone and implant. The available PBIC was calculated for each sample. Later on, the cross-sectional slices were processed by a 3-dimensional (3D) software, and 3D images of each sample were used for descriptive analysis and display the microtopography and macrotopography. The wide-diameter short implant (4.5 × 6 mm) showed the higher PBIC (210.89 mm) value followed by the standard (178.07 mm and 185.37 mm) and short implants (130.70 mm and 110.70 mm). Wide-diameter short implants show a surface area comparable with standard implants. Micro-CT analysis is a promising technique to evaluate surface area in dental implants with different macrodesign, microdesign, and surface features.

  8. Influence of irradiation (Co{sub 6}0) in pre-implant rabbits embryos: effect on blastocyst diameters and embryos smaller than 2 mm; Influencia da radiacao ionizante (bomba de cobalto) em embrioes de coelha na fase de pre-implantacao: efeito no diametro das blastulas e embrioes com menos de 2mm

    Energy Technology Data Exchange (ETDEWEB)

    Approbato, Mario S.; Oliveira Moura, Katia K.V. de; Souza Florencio, Rodopiano de; Cunha Junior, Carlos; Garcia, Ricardo; Faria, Renato S.; Benedetti, Leonardo N.; Goulart, Flamarion B.

    1995-06-01

    We studied the effect of ionizing irradiation on 12 New Zealand rabbits (65 embryos), in three different times: at match time (zero hour), two days after and four days after, with two different irradiation doses, 5 c Gy and 10 c Gy. Six rabbits (36 blastocysts) were used as controls. The matching instant was the zero hour. Exactly six days after ({+-} 60 minutes) the embryos of each rabbit was picked up by flushing the uterus with culture media. The embryos were fixed in methanol for 48 hours, and colored with acid Mayer hematoxylin. The following embryos parameters were studied: diameter growth; percentage of embryos smaller than 2 mm. We observed that only the irradiation time influenced the blastocysts diameter (no irradiation dose). There was no relation between percentage of embryos smaller than 2 mm and the irradiation. (author). 11 refs., 2 figs.

  9. Soft and Hard Tissue Changes around Tissue-Oriented Tulip-Design Implant Abutments: A 1-Year Randomized Prospective Clinical Trial.

    Science.gov (United States)

    Gutmacher, Zvi; Levi, Guy; Blumenfeld, Israel; Machtei, Eli E

    2015-10-01

    The advantages of platform switching using narrower abutments remain controversial. Many researchers suggest that platform switching can yield enhanced clinical results, while others remain skeptical. We hypothesize that the effectiveness of platform switching might be associated with the degree of reduction in size of the abutment. To radiographically and clinically examine a new abutment design created to move the implant-abutment interface farther medially. This was a prospective, randomized controlled clinical trial that included 27 patients (41 MIS Lance Plus® implants; MIS Implant Technologies, Karmiel, Israel). The patients' age ranged from 39 to 75 years. At the second stage of the surgery, the implants were randomly assigned to either the new platform switch Tulip abutment (TA) design or to the standard platform abutment (SA). Implant probing depth (IPD) and bleeding on probing (BOP) were recorded at baseline and after 12 months. Standardized periapical radiographs were taken (at baseline and at 12 months) and the marginal bone height measured. All implants were successfully integrated. The mean IPD at 1 year post-op was 2.91 mm for the SA group and 2.69 mm for the TA group (p > .05). Similarly, the BOP at 1 year was almost identical in both groups. The mean values of bone resorption at baseline were 0.98 ± 0.37 mm and 0.69 ± 0.20 for the TA and SA groups, respectively (p > .05). Bone loss (baseline to 12 months) was significantly greater in the SA group compared with the TA group. Use of the new TA, with its significantly downsized diameter, resulted in reduced bone loss at 1 year. Further research will be required to assess the long-term effect of this abutment on peri-implant health. © 2014 Wiley Periodicals, Inc.

  10. Slim 198gold-grain implanter loaded with standard royal marsden 14-grain magazines

    International Nuclear Information System (INIS)

    Delclos, L.; Moore, E.B.

    1979-01-01

    We designed a slim gold-grain implanter with adaptable lengths to implant areas accessible only through long, narrow, examining instruments, such as a suspension laryngoscope. The implanter is loaded with the same 14-grain magazine designed for and supplied with the Royal Marsden gun. The simplicity of the loading mechanism with a minimum of moving parts makes the instrument practically trouble free. Although it is designed to be used along narrow examining instruments, it can also be used in any situation in which a permanent implant is required, for instance, prostatic cancer and pelvic recurrences in cancer of the uterine cervix previously treated by external and intracavitary irradiation

  11. A study on the resistance at bone-implant interface during implant insertion in a cadaver goat jaw model

    Directory of Open Access Journals (Sweden)

    Goutam Das

    2016-01-01

    Full Text Available Background: The aim of the study is to determine the resistance at bone-implant interface during insertion of dental implant. Materials and Methods: Freshly procured cadaver goat mandibles were collected from slaughterhouses. Four dental implants of two different diameters were inserted into osteotomized sites of the goat mandibles. The gradual changes in resonance frequency (RF were recorded in RF analyzer for the five consecutive turns of implant insertion. Results and Observations: RF was found to be positively correlated with diameter of dental implants. Conclusion: RF analysis can be used to determine the type of resistance the implant faces during insertion and the kind of bone density through which it passes. It gives a forecast of expected initial stability.

  12. One-year results of maxillary overdentures supported by 2 titanium-zirconium implants - implant survival rates and radiographic outcomes.

    Science.gov (United States)

    Zembic, Anja; Tahmaseb, Ali; Jung, Ronald E; Wismeijer, Daniel

    2017-07-01

    To assess implant survival rates and peri-implant bone loss of 2 titanium-zirconium implants supporting maxillary overdentures at 1 year of loading. Twenty maxillary edentulous patients (5 women and 15 men) being dissatisfied with their complete dentures were included. In total, 40 diameter-reduced titanium-zirconium implants were placed in the anterior maxilla. Local guided bone regeneration (GBR) was allowed if the treatment did not compromise implant stability. Following 3 to 5 months of healing, implant-supported overdentures were inserted on two ball anchors. Implants and overdentures were assessed at 1, 2, 4, and 8 weeks after implant insertion and 2, 4, and 12 months after insertion of overdentures (baseline). Standardized radiographs were taken at implant loading and 1 year. Implant survival rates and bone loss were the primary outcomes. Nineteen patients (1 dropout) with 38 implants were evaluated at a mean follow-up of 1.1 years (range 1.0-1.7 years). One implant failed resulting in an implant survival rate of 97.3%. There was a significant peri-implant bone loss of the implants at 1 year of function (mean, 0.7 mm, SD = 1.1 mm; median: 0.48 mm, IQR = 0.56 mm). There was a high 1-year implant survival rate for edentulous patients receiving 2 maxillary implants and ball anchors as overdenture support. However, several implants exhibited an increased amount of bone loss of more than 2 mm. Overdentures supported by 2 maxillary implants should thus be used with caution as minimally invasive treatment for specific patients encountering problems with their upper dentures until more long-term data is available. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Effect of implant macro-design on primary stability: A prospective clinical study.

    Science.gov (United States)

    Lozano-Carrascal, Naroa; Salomó-Coll, Oscar; Gilabert-Cerdà, Marta; Farré-Pagés, Nuria; Gargallo-Albiol, Jordi; Hernández-Alfaro, Federico

    2016-03-01

    Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Mehods: A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers' standard protocols. Implant primary stability was measured at the moment of implant placement by registering insertion torque values (ITv) and ISQ values by means of Osstell™ Mentor (ISQv) (Integration Diagnostic Ltd., Goteborg, Sweden). In the mandible, mean ISQv for tapered implants (TI) was 71.67±5.16 and for cylindrical implants (CI) 57.15±4.83 (p=0.01). Mean insertion torque was 46.67±6.85 Ncm for TI and 35.77±6.72 Ncm for CI (p=0.01). In the maxilla, mean ISQ was 67.2±4.42 for tapered implants and 49.17±15.30 for cylindrical implants (p=0.01). Mean insertion torque for TI was 41.5±6.26 Ncm and for CI 39.17±6.34 Ncm (p>0.05). For tapered implants, no correlation could be found between implant diameter and primary stability. But for cylindrical implants there was a statistically significant correlation between implant diameter and primary stability: ITv (p=0.03); ISQv (p=0.04). Within the limits of the present study, tapered shaped implants achieve higher primary stability measured through ISQ and insertion torque values. Moreover, for cylindrical implants positive correlation has been established between implant diameter and primary stability.

  14. 7 CFR 51.320 - Diameter.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter...

  15. A Prospective Case-Control Clinical Study of Titanium-Zirconium Alloy Implants with a Hydrophilic Surface in Patients with Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Cabrera-Domínguez, José; Castellanos-Cosano, Lizett; Torres-Lagares, Daniel; Machuca-Portillo, Guillermo

    To evaluate prospectively the behavior of narrow-diameter (3.3-mm) titanium-zirconium alloy implants with a hydrophilic surface (Straumann Roxolid SLActive) in patients with type 2 diabetes mellitus in single-unit restorations, compared with a healthy control group (assessed using the glycosylated hemoglobin HbA1c test). The patients evaluated in this study required single-unit implant treatment; 15 patients had type 2 diabetes mellitus, and 14 patients were healthy (control group [CG]). Marginal bone level (MBL) change around the implants was evaluated using conventional, sequential periapical digital radiographs. Patient HbA1c was assessed in each check-up. Normality test (Kolmogorov-Smirnov), univariate and multivariate logistic regression, analysis of variance (ANOVA), and Mann-Whitney U test were used for statistical analysis. No differences in MBL change and implant survival and success rates were found between the diabetes mellitus group (DMG) versus the control group, either during the initial recording (DMG, 0.99 ± 0.56 vs CG, 0.68 ± 0.54; P > .05) or 6 months after restoration (DMG, 1.28 ± 0.38 vs CG, 1.11 ± 0.59; P > .05). No significant correlation between HbA1c levels and MBL change was detected in these patients (P > .05). Patients with glycemic control exhibit similar outcomes to healthy individuals with regard to the investigated parameters. In light of these findings, the titanium-zirconium alloy small-diameter implants can be used in the anterior region of the mouth in type 2 diabetic patients.

  16. Diameter-dependent coloration of silver nanowires

    International Nuclear Information System (INIS)

    Stewart, Mindy S; Qiu Chao; Jiang Chaoyang; Kattumenu, Ramesh; Singamaneni, Srikanth

    2011-01-01

    Silver nanowires were synthesized with a green method and characterized with microscopic and diffractometric methods. The correlation between the colors of the nanowires deposited on a solid substrate and their diameters was explored. Silver nanowires that appear similar in color in the optical micrographs have very similar diameters as determined by atomic force microscopy. We have summarized the diameter-dependent coloration for these silver nanowires. An optical interference model was applied to explain such correlation. In addition, microreflectance spectra were obtained from individual nanowires and the observed spectra can be explained with the optical interference theory. This work provides a cheap, quick and simple screening method for studying the diameter distribution of silver nanowires, as well as the diameter variations of individual silver nanowires, without complicated sample preparation.

  17. Highly Tunable Narrow Bandpass MEMS Filter

    KAUST Repository

    Hafiz, Md Abdullah Al

    2017-07-07

    We demonstrate a proof-of-concept highly tunable narrow bandpass filter based on electrothermally and electrostatically actuated microelectromechanical-system (MEMS) resonators. The device consists of two mechanically uncoupled clamped-clamped arch resonators, designed such that their resonance frequencies are independently tuned to obtain the desired narrow passband. Through the electrothermal and electrostatic actuation, the stiffness of the structures is highly tunable. We experimentally demonstrate significant percentage tuning (~125%) of the filter center frequency by varying the applied electrothermal voltages to the resonating structures, while maintaining a narrow passband of 550 ± 50 Hz, a stopband rejection of >17 dB, and a passband ripple ≤ 2.5 dB. An analytical model based on the Euler-Bernoulli beam theory is used to confirm the behavior of the filter, and the origin of the high tunability using electrothermal actuation is discussed.

  18. Evaluation of primary and secondary stability of titanium implants using different surgical techniques

    NARCIS (Netherlands)

    Tabassum, A.; Meijer, G.J.; Walboomers, X.F.; Jansen, J.A.

    2014-01-01

    OBJECTIVE: To investigate the influence of different surgical techniques on the primary and secondary implant stability using trabecular bone of goats as an implantation model. MATERIAL AND METHODS: In the iliac crest of eight goats, 48 cylindrical-screw-type implants with a diameter of 4.2 mm

  19. Generic Post-closure Safety Assessment for Disposal of Disused Sealed Radioactive Sources in Narrow Diameter Boreholes

    International Nuclear Information System (INIS)

    2017-10-01

    This publication, prepared in light of the IAEA Action Plan on Nuclear Safety developed after the accident at the Fukushima Daiichi nuclear power plant, addresses the management of large volumes of radioactive waste arising in a nuclear or radiological emergency, as part of overall emergency preparedness. The management of large volumes of waste will be one of many efforts to be dealt with to allow recovery of affected areas, to support return of evacuated or relocated populations and preparations for normal social and economic activities, and/or to mitigate additional environmental impacts. The publication is intended to be of use to national planners and policy makers, facility and programme managers, and other professionals responsible for developing and implementing national plans and strategies to manage radioactive waste arising from nuclear or radiological emergencies.

  20. Natural Convective Heat Transfer from Narrow Plates

    CERN Document Server

    Oosthuizen, Patrick H

    2013-01-01

    Natural Convective Heat Transfer from Narrow Plates deals with a heat transfer situation that is of significant practical importance but which is not adequately dealt with in any existing textbooks or in any widely available review papers. The aim of the book is to introduce the reader to recent studies of natural convection from narrow plates including the effects of plate edge conditions, plate inclination, thermal conditions at the plate surface and interaction of the flows over adjacent plates. Both numerical and experimental studies are discussed and correlation equations based on the results of these studies are reviewed.

  1. A naturally narrow positive-parity Θ+

    International Nuclear Information System (INIS)

    Carlson, Carl E.; Carone, Christopher D.; Kwee, Herry J.; Nazaryan, Vahagn

    2004-01-01

    We present a consistent color-flavor-spin-orbital wave function for a positive-parity Θ + that naturally explains the observed narrowness of the state. The wave function is totally symmetric in its flavor-spin part and totally antisymmetric in its color-orbital part. If flavor-spin interactions dominate, this wave function renders the positive-parity Θ + lighter than its negative-parity counterpart. We consider decays of the Θ + and compute the overlap of this state with the kinematically allowed final states. Our results are numerically small. We note that dynamical correlations between quarks are not necessary to obtain narrow pentaquark widths

  2. Narrow Escape of Interacting Diffusing Particles

    Science.gov (United States)

    Agranov, Tal; Meerson, Baruch

    2018-03-01

    The narrow escape problem deals with the calculation of the mean escape time (MET) of a Brownian particle from a bounded domain through a small hole on the domain's boundary. Here we develop a formalism which allows us to evaluate the nonescape probability of a gas of diffusing particles that may interact with each other. In some cases the nonescape probability allows us to evaluate the MET of the first particle. The formalism is based on the fluctuating hydrodynamics and the recently developed macroscopic fluctuation theory. We also uncover an unexpected connection between the narrow escape of interacting particles and thermal runaway in chemical reactors.

  3. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  4. Thermal behaviour of nitrogen implanted into zirconium

    International Nuclear Information System (INIS)

    Miyagawa, S.; Ikeyama, M.; Saitoh, K.; Nakao, S.; Niwa, H.; Tanemura, S.; Miyagawa, Y.

    1994-01-01

    Zirconium films were implanted with 15 N ions of energy 50keV to a total fluence of 1x10 18 ionscm -2 in an attempt to study the formation process and thermal stability of ZrN layers produced by high fluence implantation of nitrogen. Subsequent to the implantation at room temperature, samples were annealed at temperatures of 300 C-900 C. The depth profiles of the implanted nitrogen were measured by nuclear reaction analysis using the 15 N(p,αγ) 12 C at E R =429keV, and the surfaces were examined by thin film X-ray diffraction (XRD) and scanning electron microscopy. There were many blisters 0.2-0.4μm in diameter on the surface of the as-implanted samples and double peaks were observed in the nitrogen depth profiles; they were in both sides of the mean projected range. It was found that most of the blisters became extinct after annealing above 400 C, and the XRD peak (111) intensity was increased with the increase in the annealing temperature. Moreover, 14 N and 15 N implantations were superimposed on Zr samples in order to study the atomic migration of nitrogen at each stage of high fluence implantation. It was found that the decrease in the peak at the deeper layers was related to blister extinction and nitrogen diffusion into underling zirconium which could be correlated with radiation damage induced by post-implanted ions. ((orig.))

  5. Clinical evaluation of the stability of implants placed at different supracrestal levels.

    Science.gov (United States)

    Gultekin, B Alper; Sirali, Ali; Gultekin, Pinar; Ersanli, Selim

    2016-01-01

    The aim of this study was to evaluate the stability during healing and before loading of implants placed at two different supracrestal levels according to their collar texture. This retrospective study included patients who received posterior implants with the same macro design. Implants with a machined collar were placed 0.3 mm above the crestal bone (M group), while those with a laser-microtextured collar were placed 1 mm above the crestal bone (L group). All implants healed in a single stage with healing abutments. Implant stability quotient (ISQ) values were determined using resonance frequency analysis immediately after implant placement during surgery and after 1, 4, 8, and 12 weeks after surgery. Other evaluated factors for stability included the implant diameter and length and the site of placement (maxilla or mandible). In total, 103 implants (47 L, 56 M) were evaluated. The median ISQ values at baseline and 1 week after placement were significantly higher for the M group than for the L group (p=0.006 and p=0.031, respectively). There were no differences at the subsequent observation points. The ISQ value was higher for wide-diameter than regular diameter (p=0.001) and mandibular implants than maxillary implants (p=0.001 at 0-8. weeks; p=0.012 at 12 weeks) at all observation points. When diameter data were neglected, the implant length did not influence the ISQ value at all observation points. Our results suggest that submerging implant more inside bone may only influence primary stability. Moreover, the implant diameter and site of placement influence primary and secondary stability before loading, whereas the implant length does not when its diameter is not accounted for.

  6. CLINICAL EVALUATION OF THE STABILITY OF IMPLANTS PLACED AT DIFFERENT SUPRACRESTAL LEVELS

    Directory of Open Access Journals (Sweden)

    B. Alper GÜLTEKIN

    2016-10-01

    Full Text Available Purpose: The aim of this study was to evaluate the stability during healing and before loading of implants placed at two different supracrestal levels according to their collar texture. Materials and Methods: This retrospective study included patients who received posterior implants with the same macro design. Implants with a machined collar were placed 0.3 mm above the crestal bone (M group, while those with a laser-microtextured collar were placed 1 mm above the crestal bone (L group. All implants healed in a single stage with healing abutments. Implant stability quotient (ISQ values were determined using resonance frequency analysis immediately after implant placement during surgery and after 1, 4, 8, and 12 weeks after surgery. Other evaluated factors for stability included the implant diameter and length and the site of placement (maxilla or mandible. Results: In total, 103 implants (47 L, 56 M were evaluated. The median ISQ values at baseline and 1 week after placement were significantly higher for the M group than for the L group (p=0.006 and p=0.031, respectively. There were no differences at the subsequent observation points. The ISQ value was higher for wide-diameter than regular diameter (p=0.001 and mandibular implants than maxillary implants (p=0.001 at 0-8. weeks; p=0.012 at 12 weeks at all observation points. When diameter data were neglected, the implant length did not influence the ISQ value at all observation points. Conclusion: Our results suggest that submerging implant more inside bone may only influence primary stability. Moreover, the implant diameter and site of placement influence primary and secondary stability before loading, whereas the implant length does not when its diameter is not accounted for.

  7. Threat but not arousal narrows attention: Evidence from pupil dilation and saccade control

    Directory of Open Access Journals (Sweden)

    Henk eVan Steenbergen

    2011-10-01

    Full Text Available It has been shown that negative affect causes attentional narrowing. According to Easterbrook’s (1959 influential hypothesis this effect is driven by the withdrawal motivation inherent to negative emotions and might be related to increases in arousal. We investigated whether valence-unspecific increases in physiological arousal, as measured by pupil dilation, could account for attentional narrowing effects in a cognitive control task. Following the presentation of a negative, positive, or neutral picture, participants performed a saccade task with a prosaccade versus an antisaccade instruction. The reaction time difference between pro- and antisaccades was used to index attentional selectivity, and while pupil diameter was used as an index of physiological arousal. Pupil dilation was observed for both negative and positive pictures, which indicates increased physiological arousal. However, increased attentional selectivity was only observed following negative pictures. Our data show that motivational intensity effects on attentional narrowing can occur independently of physiological arousal effects.

  8. The biocompatibility of SLA-treated titanium implants

    International Nuclear Information System (INIS)

    Kim, Hyeongil; Choi, Seong-Ho; Ryu, Jae-Jun; Koh, Seung-Yong; Park, Ju-Han; Lee, In-Seop

    2008-01-01

    The titanium implant surface was sandblasted with large grits and acid etched (SLA) to increase the implant surface for osseointegration. The topography of the titanium surface was investigated with scanning electron microscopy (SEM) and a profilometer. The SLA implant demonstrated uniform small micro pits (1-2 μm in diameter). The values of average roughness (R a ) and maximum height (R t ) were 1.19 μm and 10.53 μm respectively after sandblasting and the acid-etching treatment. In the cell-surface interaction study, the human osteoblast cells grew well in vitro. The in vivo evaluation of the SLA implant placed in rabbit tibia showed good bone-to-implant contact (BIC) with a mean value of 29% in total length of the implant. In the short-term clinical study, SLA implants demonstrated good clinical performance, maintaining good crestal bone height

  9. Narrow linewidth pulsed optical parametric oscillator

    Indian Academy of Sciences (India)

    Tunable narrow linewidth radiation by optical parametric oscillation has many applications, particularly in spectroscopic investigation. In this paper, different techniques such as injection seeding, use of spectral selecting element like grating, grating and etalon in combination, grazing angle of incidence, entangled cavity ...

  10. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    Underlying ion-beam modification of surfaces is the more basic subject of particle-surface interaction. The ideas can be grouped into forward and backward features, i.e. those affecting the interior of the target and those leading to particle expulsion. Forward effects include the stopping of the incident particles and the deposition of energy, both governed by integral equations which are easily set up but difficult to solve. Closely related is recoil implantation where emphasis is placed not on the stopping of the incident particles but on their interaction with target atoms with resulting implantation of these atoms. Backward effects, all of which are denoted as sputtering, are in general either of collisional, thermal, electronic, or exfoliational origin. (Auth.)

  11. Normal ureteral diameter in infancy and childhood

    International Nuclear Information System (INIS)

    Hellstroem, M.; Hjaelmaas, K.; Jacobsson, B.; Jodal, U.; Oden, A.; Oestra Sjukhuset, Goeteborg; Oestra Sjukhuset, Goeteborg; Goeteborg Univ.

    1985-01-01

    Ureteral diameters were estimated on films from intravenous urography in 194 children (100 boys and 94 girls) aged 0-16 years. Children with signs of urinary tract infection, calculi, obstruction, duplication or malformation were excluded. Films obtained without abdominal compression were used for measurements, including only ureters visualized over 50 per cent of their lengths. A good correlation was demonstrated between ureteral diameter and age and between ureteral diameter and the length of a segment of the lumbar spine. The widest part of the ureter was most often located just above the crossing of the iliac vessels. The right ureter was slightly wider than the left one. No difference between boys and girls was noted. The results are in good agreement with those of others obtained at autopsy. Bearing in mind the possible physiologic variations, it would seem that measuring the ureteral diameter can be of value for a more objective differentiation between dilated and non-dilated ureters. (orig.)

  12. SEX DETERMINATION FROM FEMORAL HEAD DIAMETERS IN ...

    African Journals Online (AJOL)

    hi-tech

    2000-03-01

    Mar 1, 2000 ... In medico-legal cases where sophisticated methods of sex determination is lacking, these ... scientific methods(3). Using the visual method ... between the sexes and the values of the right and left femoral head diameters.

  13. Effective diameters and corresponding states of fluids

    Science.gov (United States)

    Del Río, Fernando

    Effective hard-sphere diameters of fluids with purely repulsive interactions are derived from a generalized corresponding-states principle of Leland, Rowlinson and coworkers. Various alternative definitions are discussed and related. Virial expansions of the effective diameters and their corresponding volumes are obtained and compared with results of perturbation theory. Applications are made to inverse-power potentials, the repulsive part of the Lennard-Jones potential and hard spherocylinders and dumbells.

  14. Appendiceal diameter: CT versus sonographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orscheln, Emily S. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati, OH (United States); Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-03-15

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  15. Small Diameter Bomb Increment II (SDB II)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-439 Small Diameter Bomb Increment II (SDB II) As of FY 2017 President’s Budget Defense... Bomb Increment II (SDB II) DoD Component Air Force Joint Participants Department of the Navy Responsible Office References SAR Baseline (Production...Mission and Description Small Diameter Bomb Increment II (SDB II) is a joint interest United States Air Force (USAF) and Department of the Navy

  16. Appendiceal diameter: CT versus sonographic measurements

    International Nuclear Information System (INIS)

    Orscheln, Emily S.; Trout, Andrew T.

    2016-01-01

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  17. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  18. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  19. Evolution of deformation velocity in narrowing for Zircaloy 2

    Energy Technology Data Exchange (ETDEWEB)

    Cetlin, P R [Minas Gerais Univ., Belo Horizonte (Brazil). Dept. de Engenharia Metalurgica; Okuda, M Y [Goias Univ., Goiania (Brazil). Inst. de Matematica e Fisica

    1980-09-01

    Some studies on the deformation instability in strain shows that the differences in this instability may lead to localized narrowing or elongated narrowing, for Zircaloy-2. The variation of velocity deformation with the narrowing evolution is expected to be different for these two cases. The mentioned variation is discussed, a great difference in behavior having been observed for the case of localized narrowing.

  20. Tracheid diameter is the key trait determining the extent of freezing-induced embolism in conifers.

    Science.gov (United States)

    Pittermann, Jarmila; Sperry, John

    2003-09-01

    We tested the hypotheses that freezing-induced embolism is related to conduit diameter, and that conifers and angiosperms with conduits of equivalent diameter will exhibit similar losses of hydraulic conductivity in response to freezing. We surveyed the freeze-thaw response of conifers with a broad range of tracheid diameters by subjecting wood segments (root, stem and trunk wood) to a freeze-thaw cycle at -0.5 MPa in a centrifuge. Embolism increased as mean tracheid diameter exceeded 30 microm. Tracheids with a critical diameter greater than 43 microm were calculated to embolize in response to freezing and thawing at a xylem pressure of -0.5 MPa. To confirm that freezing-induced embolism is a function of conduit air content, we air-saturated stems of Abies lasiocarpa (Hook.) Nutt. (mean conduit diameter 13.7 +/- 0.7 microm) by pressurizing them 1 to 60 times above atmospheric pressure, prior to freezing and thawing. The air saturation method simulated the effect of increased tracheid size because the degree of super-saturation is proportional to a tracheid volume holding an equivalent amount of dissolved air at ambient pressure. Embolism increased when the dissolved air content was equivalent to a mean tracheid diameter of 30 microm at ambient air pressure. Our centrifuge and air-saturation data show that conifers are as vulnerable to freeze-thaw embolism as angiosperms with equal conduit diameter. We suggest that the hydraulic conductivity of conifer wood is maximized by increasing tracheid diameters in locations where freezing is rare. Conversely, the narrowing of tracheid diameters protects against freezing-induced embolism in cold climates.

  1. Evaluation of mandibular posterior single implants with two different surfaces: a 5-year comparative study.

    Science.gov (United States)

    Jung, Ui-Won; Choi, Jung-Yoo; Kim, Chang-Sung; Cho, Kyoo-Sung; Chai, Jung-Kiu; Kim, Chong-Kwan; Choi, Seong-Ho

    2008-10-01

    Anatomic and biomechanical limitations can jeopardize successful single implantation in the mandibular posterior area. To overcome the limitations, the design and the surface of the fixtures were modified. This study evaluated the cumulative survival rate (CSR) of mandibular molars replaced with a sand-blasted, large-grit, acid-etched (SLA) single implant or an anodized (ANO) single implant and examined associated factors, such as the surface treatment, position, and length and diameter of the implants. One hundred ninety-three single implants restored with an SLA implant and 112 single implants restored with an ANO implant in the mandibular molar area were selected from subjects who had visited the Department of Periodontology, Dental Hospital of Yonsei University, from March 2001 through June 2006. In the SLA group, 123 and 70 implants were placed in the first and second molar area, respectively. In the ANO group, 55 and 57 implants were placed in the first and second molar area, respectively. The 1- to 6-year CSR of the SLA and ANO groups was calculated using the life-table analysis. In addition, associated factors, such as the surface treatment, position, and length and diameter of the implants, were compared and analyzed using the chi(2) test (P CSR of 98.96%; four of 112 ANO implants failed, giving a CSR of 96.43%. There were no significant differences with regard to the surface treatment, position, and length and diameter of the implants. Despite the anatomic and biomechanical limitation in the mandibular posterior area, mandibular posterior single implants showed a high CSR during the observation period. Mandibular posterior single implants can be an effective and reliable treatment modality that is not affected by the surface treatment, position, or length and diameter of the implant.

  2. Single versus dual renal transplantation from donors with significant arteriosclerosis on pre-implant biopsy.

    Science.gov (United States)

    Kayler, Liise K; Mohanka, Ravi; Basu, Amit; Shapiro, Ron; Randhawa, Parmjeet S

    2009-01-01

    Transplantation of kidneys from donor with arteriosclerosis seen on pre-implantation biopsy has not been well studied. We retrospectively evaluated 20 dual kidney transplant (DKT) and 28 single (SKT) kidney transplant recipients with >or=12 months follow-up from donors with moderate arteriosclerosis (>or=25% luminal diameter narrowing). Death censored graft survival was 100% and 79%, respectively (p = 0.0339). DKT recipients had significantly lower mean creatinine levels at one, three, six, and nine months and spent somewhat less time on the waiting list (181 +/- 160 vs. 318 +/- 306 d, p = 0.1429). DKT patients received kidneys from significantly older donors (64 +/- 7 vs. 54 +/- 11 yr; p = 0.0012), proportionately more expanded criteria donors (95% vs. 54%; p = 0.0029), and more donors with hypertension (81% vs. 48%, p = 0.0344) and death related to cerebrovascular accident (100% vs. 71%, p = 0.0143); however, more DKT kidneys underwent machine perfusion (95% vs. 57%, p = 0.0068). Baseline recipient variables were comparable between the two groups including age, race, gender, retransplantation, and HLA mismatch. Pre-implant biopsy was notable for similar frequencies of moderate interstitial fibrosis (10% vs. 14%, respectively) and glomerulosclerosis. Among recipients of deceased-donor kidneys with >25% arteriosclerosis, short-term outcomes after DKT were superior to that of SKT grafts. This approach may help to expand the donor-organ pool while optimizing outcomes.

  3. Dosimetry and monitoring of X-rays narrow beams produced by linear particle accelerator, for using in radiosurgery

    International Nuclear Information System (INIS)

    Campos, J.C.F.; Vizeu, D.M.

    1987-01-01

    The main characteristics of X-rays narrow beams dosimetry and monitoring are examined, aiming the introduction of this system in brain radiosurgery. The non-protocolize detectors are used, once that the detectors used in therapy by megavoltage were projected for dosimetry with an irradiation field above 40 mm diameter. (C.G.C.) [pt

  4. Comparison of urethral diameters for calculating the urethral dose after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Nakano, Masahiro; Kubota, Yasuaki; Maeda, Sunaho; Ohtakara, Kazuhiro; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    No studies have yet evaluated the effects of a dosimetric analysis for different urethral volumes. We therefore evaluated the effects of a dosimetric analysis to determine the different urethral volumes. This study was based on computed tomography/magnetic resonance imaging (CT/MRI) combined findings in 30 patients who had undergone prostate brachytherapy. Postimplant CT/MRI scans were performed 30 days after the implant. The urethra was contoured based on its diameter (8, 6, 4, 2, and 0 mm). The total urethral volume-in cubic centimeters [UrV150/200 (cc)] and percent (UrV150%/200%), of the urethra receiving 150% or 200% of the prescribed dose-and the doses (UrD90/30/5) in Grays to 90%, 30%, and 5% of the urethral volume were measured based on the urethral diameters. The UrV150 (cc) and UrD30 were statistically different between the of 8-, 6-, 4-, 2-, and 0-mm diameters, whereas the UrD5 was statistically different only between the 8-, 6-, and 4-mm diameters. Especially for UrD5, there was an approximately 40-Gy difference between the mean values for the 8- and 0-mm diameters. We recommend that the urethra should be contoured as a 4- to 6-mm diameter circle or one side of a triangle of 5-7 mm. By standardizing the urethral diameter, the urethral dose will be less affected by the total urethral volume. (author)

  5. Analytical approximations for wide and narrow resonances

    International Nuclear Information System (INIS)

    Suster, Luis Carlos; Martinez, Aquilino Senra; Silva, Fernando Carvalho da

    2005-01-01

    This paper aims at developing analytical expressions for the adjoint neutron spectrum in the resonance energy region, taking into account both narrow and wide resonance approximations, in order to reduce the numerical computations involved. These analytical expressions, besides reducing computing time, are very simple from a mathematical point of view. The results obtained with this analytical formulation were compared to a reference solution obtained with a numerical method previously developed to solve the neutron balance adjoint equations. Narrow and wide resonances of U 238 were treated and the analytical procedure gave satisfactory results as compared with the reference solution, for the resonance energy range. The adjoint neutron spectrum is useful to determine the neutron resonance absorption, so that multigroup adjoint cross sections used by the adjoint diffusion equation can be obtained. (author)

  6. Analytical approximations for wide and narrow resonances

    Energy Technology Data Exchange (ETDEWEB)

    Suster, Luis Carlos; Martinez, Aquilino Senra; Silva, Fernando Carvalho da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: aquilino@lmp.ufrj.br

    2005-07-01

    This paper aims at developing analytical expressions for the adjoint neutron spectrum in the resonance energy region, taking into account both narrow and wide resonance approximations, in order to reduce the numerical computations involved. These analytical expressions, besides reducing computing time, are very simple from a mathematical point of view. The results obtained with this analytical formulation were compared to a reference solution obtained with a numerical method previously developed to solve the neutron balance adjoint equations. Narrow and wide resonances of U{sup 238} were treated and the analytical procedure gave satisfactory results as compared with the reference solution, for the resonance energy range. The adjoint neutron spectrum is useful to determine the neutron resonance absorption, so that multigroup adjoint cross sections used by the adjoint diffusion equation can be obtained. (author)

  7. Diameter effect on critical heat flux

    International Nuclear Information System (INIS)

    Tanase, A.; Cheng, S.C.; Groeneveld, D.C.; Shan, J.Q.

    2009-01-01

    The critical heat flux look-up table (CHF LUT) is widely used to predict CHF for various applications, including design and safety analysis of nuclear reactors. Using the CHF LUT for round tubes having inside diameters different from the reference 8 mm involves conversion of CHF to 8 mm. Different authors [Becker, K.M., 1965. An Analytical and Experimental Study of Burnout Conditions in Vertical Round Ducts, Aktiebolaget Atomenergie Report AE 177, Sweden; Boltenko, E.A., et al., 1989. Effect of tube diameter on CHF at various two phase flow regimes, Report IPE-1989; Biasi, L., Clerici, G.C., Garriba, S., Sala, R., Tozzi, A., 1967. Studies on Burnout, Part 3, Energia Nucleare, vol. 14, pp. 530-536; Groeneveld, D.C., Cheng, S.C., Doan, T., 1986. AECL-UO critical heat flux look-up table. Heat Transfer Eng., 7, 46-62; Groeneveld et al., 1996; Hall, D.D., Mudawar, I., 2000. Critical heat flux for water flow in tubes - II subcooled CHF correlations. Int. J. Heat Mass Transfer, 43, 2605-2640; Wong, W.C., 1996. Effect of tube diameter on critical heat flux, MaSC dissertation, Ottawa Carleton Institute for Mechanical and Aeronautical Engineering, University of Ottawa] have proposed several types of correlations or factors to describe the diameter effect on CHF. The present work describes the derivation of new diameter correction factor and compares it with several existing prediction methods

  8. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  9. Narrow nuclear resonance profiling of Al with subnanometric depth resolution

    International Nuclear Information System (INIS)

    Rosa, E.B.O. da; Krug, C.; Stedile, F.C.; Morais, J.; Baumvol, I.J.R.

    2002-01-01

    We report on the use of the narrow and isolated resonance at 404.9 keV in the cross-section curve of the 27 Al(p,γ) 28 Si nuclear reaction for profiling Al in ultrathin aluminum oxide films on Si. The samples were characterized as-deposited and after thermal annealing, so that Al transport could be studied. An estimated depth resolution of approximately 0.4 nm near the surface of the films could be obtained owing to: (i) the very small resonance width; (ii) the high stopping power of Al 2 O 3 for 404.9 keV protons; (iii) the high energy stability of the proton beam provided by the 500 kV HVEE ion implanter at Porto Alegre; and (iv) an apparent thickness magnification by a factor between 2.0 and 2.4 with the use of glancing incidence. This technique is compared to other methods for Al profiling like medium energy ion scattering and some sputtering-based techniques

  10. Dose evaluation of narrow-beam

    International Nuclear Information System (INIS)

    Goto, Shinichi

    1999-01-01

    Reliability of the dose from the narrow photon beam becomes more important since the single high-dose rate radiosurgery becoming popular. The dose evaluation for the optimal dose is difficult due to absence of lateral electronic equilibrium. Data necessary for treatment regimen are TMR (tissue maximum ratio), OCR (off center ratio) and S c,p (total scatter factor). The narrow-beam was 10 MV X-ray from Varian Clinac 2100C equipped with cylindrical Fischer collimator CBI system. Detection was performed by Kodak XV-2 film, a PTW natural diamond detector M60003, Scanditronics silicon detector EDD-5 or Fujitec micro-chamber FDC-9.4C. Phantoms were the water equivalent one (PTW, RW3), water one (PTW, MP3 system) and Wellhofer WP600 system. Factors above were actually measured to reveal that in the dose evaluation of narrow photon beam, TMR should be measured by micro-chamber, OCR, by film, and S c,p , by the two. The use of diamond detector was recommended for more precise measurement and evaluation of the dose. The importance of water phantom in the radiosurgery system was also shown. (K.H.)

  11. Electron correlations in narrow band systems

    International Nuclear Information System (INIS)

    Kishore, R.

    1983-01-01

    The effect of the electron correlations in narrow bands, such as d(f) bands in the transition (rare earth) metals and their compounds and the impurity bands in doped semiconductors is studied. The narrow band systems is described, by the Hubbard Hamiltonian. By proposing a local self-energy for the interacting electron, it is found that the results are exact in both atomic and band limits and reduce to the Hartree Fock results for U/Δ → 0, where U is the intra-atomic Coulomb interaction and Δ is the bandwidth of the noninteracting electrons. For the Lorentzian form of the density of states of the noninteracting electrons, this approximation turns out to be equivalent to the third Hubbard approximation. A simple argument, based on the mean free path obtained from the imaginary part of the self energy, shows how the electron correlations can give rise to a discontinous metal-nonmetal transition as proposed by Mott. The band narrowing and the existence of the satellite below the Fermi energy in Ni, found in photoemission experiments, can also be understood. (Author) [pt

  12. Are short implants in the mandible safe?

    Directory of Open Access Journals (Sweden)

    Sergio Henrique Gonçalves Motta

    2009-10-01

    Full Text Available Objective: To analyze the importance of bioengineering and the improvement in surgical techniques demonstrated by the rates attained of the prevalence of successful placement of dental implants in the posterior region of the mandible, in D3 bone quality in patients between the ages of 52 and 60 years, with dentures fixed on 8.5 mm implants. Methods: The statistical data for this retrospective study were collected at the Post-Graduation Center of the Integrated Dentistry Center, Faculty of Sarandi / Academy of Dentistry - Rio de Janeiro, at the CLIVO clinic, from among a total of 2.294 implants placed in the mandible, in the period from 1999 to 2007. There was a total of 1.056 short implants, of a length shorter than or equal to 10 mm, among which 20 implants were randomly chosen and analyzed. Results: The data were treated statistically and comparison of these data was consubstantiated in constructive data analysis by means of Statistical Pattern Recognition Methods for each variable under study. A success rate of 85% was obtained, and the need to take certain care when indicating the use of short implants was verified. Conclusion: Bioengineering and the development of present day surgical techniques have optimized the use of short implants, with the aim of avoiding advanced surgeries. To compensate the smaller size, there are some factors that must be observed, such as: Bone quality, crown/implant ratio, number and diameter of implants, macroscopic and microscopic geometry of the implants, magnitude of mesial occlusal forces.

  13. Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection.

    Science.gov (United States)

    Yoshida, Naohisa; Toyonaga, Takashi; Murakami, Takaaki; Hirose, Ryohei; Ogiso, Kiyoshi; Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Kishimoto, Mitsuo; Ohara, Yoshiko; Azuma, Takeshi; Itoh, Yoshito

    2017-01-01

    With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results.

  14. Measuring Electrospun Nanofibre Diameter: a Novel Approach

    International Nuclear Information System (INIS)

    Ziabari, M.; Mottaghitalab, V.; Haghi, A. K.; McGovern, S. T.

    2008-01-01

    A new method based on image analysis for electrospun nanofibre diameter measurement is presented. First, the SEM micrograph of the nanofibre web obtained by electrospinning process is converted to binary image using local thresholding method. In the next step, skeleton and distance transformed image are generated. Then, the intersection points which bring about untrue measurements are identified and removed from the skeleton. Finally, the resulting skeleton and distance transformed image are used to determine fibre diameter. The method is evaluated by a simulated image with known characteristics generated by ?-randomness procedure. The results indicate that this approach is successful in making fast, accurate automated measurements of electrospun fibre diameters. (cross-disciplinary physics and related areas of science and technology)

  15. Moisture monitoring in large diameter boreholes

    International Nuclear Information System (INIS)

    Tyler, S.

    1985-01-01

    The results of both laboratory and field experiments indicate that the neutron moisture gauge traditionally used in soil physics experiments can be extended for use in large diameter (up to 15 cm) steel-cased boreholes with excellent results. This application will permit existing saturated zone monitoring wells to be used for unsaturated zone monitoring of recharge, redistribution and leak detection from waste disposal facilities. Its applicability to large diameter cased wells also gives the soil physicist and ground-water hydrologist and new set of monitoring points in the unsaturated zone to study recharge and aquifer properties. 6 refs., 6 figs., 2 tabs

  16. Pool Boiling CHF in Inclined Narrow Annuli

    International Nuclear Information System (INIS)

    Kang, Myeong Gie

    2010-01-01

    Pool boiling heat transfer has been studied extensively since it is frequently encountered in various heat transfer equipment. Recently, it has been widely investigated in nuclear power plants for application to the advanced light water reactors designs. Through the review on the published results it can be concluded that knowledge on the combined effects of the surface orientation and a confined space on pool boiling heat transfer is of great practical importance and also of great academic interest. Fujita et al. investigated pool boiling heat transfer, from boiling inception to the critical heat flux (CHF, q' CHF ), in a confined narrow space between heated and unheated parallel rectangular plates. They identified that both the confined space and the surface orientation changed heat transfer much. Kim and Suh changed the surface orientation angles of a downward heating rectangular channel having a narrow gap from the downward-facing position (180 .deg.) to the vertical position (90 .deg.). They observed that the CHF generally decreased as the inclination angle (θ ) increased. Yao and Chang studied pool boiling heat transfer in a confined heat transfer for vertical narrow annuli with closed bottoms. They observed that when the gap size ( s ) of the annulus was decreased the effect of space confinement to boiling heat transfer increased. The CHF was occurred at much lower value for the confined space comparing to the unconfined pool boiling. Pool boiling heat transfer in narrow horizontal annular crevices was studied by Hung and Yao. They concluded that the CHF decreased with decreasing gap size of the annuli and described the importance of the thin film evaporation to explain the lower CHF of narrow crevices. The effect of the inclination angle on the CHF on countercurrent boiling in an inclined uniformly heated tube with closed bottoms was also studied by Liu et al. They concluded that the CHF reduced with the inclination angle decrease. A study was carried out

  17. Self-regulating and diameter-selective growth of GaN nanowires

    International Nuclear Information System (INIS)

    Kuo, C-K; Hsu, C-W; Wu, C-T; Lan, Z-H; Mou, C-Y; Chen, C-C; Yang, Y-J; Chen, L-C; Chen, K-H

    2006-01-01

    We report diameter-selective growth of GaN nanowires (NWs) by using mono-dispersed Au nanoparticles (NPs) on a ligand-modified Si substrate. The thiol-terminal silane was found to be effective in producing well-dispersed Au NPs in low density on Si substrates so that the agglomeration of Au NPs during growth could be avoided. The resultant GaN NWs exhibited a narrow diameter distribution and their mean diameter was always larger than, while keeping a deterministic relation with, the size of the Au NPs from which they were grown. A self-regulating steady growth model is proposed to account for the size-control process

  18. Group D. Initiator paper. Implants--peri-implant (hard and soft tissue) interactions in health and disease: the impact of explosion of implant manufacturers.

    Science.gov (United States)

    Ivanovski, Saso

    2015-01-01

    1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.

  19. The effect of glenosphere diameter in reverse shoulder arthroplasty on muscle force, joint load, and range of motion.

    Science.gov (United States)

    Langohr, G Daniel G; Giles, Joshua W; Athwal, George S; Johnson, James A

    2015-06-01

    Little is known about the effects of glenosphere diameter on shoulder joint loads. The purpose of this biomechanical study was to investigate the effects of glenosphere diameter on joint load, load angle, and total deltoid force required for active abduction and range of motion in internal/external rotation and abduction. A custom, instrumented reverse shoulder arthroplasty implant system capable of measuring joint load and varying glenosphere diameter (38 and 42 mm) and glenoid offset (neutral and lateral) was implanted in 6 cadaveric shoulders to provide at least 80% power for all variables. A shoulder motion simulator was used to produce active glenohumeral and scapulothoracic motion. All implant configurations were tested with active and passive motion with joint kinematics, loads, and moments recorded. At neutral and lateralized glenosphere positions, increasing diameter significantly increased joint load (+12 ± 21 N and +6 ± 9 N; P  .8). Passive internal rotation was reduced with increased diameter at both neutral and lateralized glenosphere positions (-6° ± 6° and -12° ± 6°; P  .05). At neutral glenosphere position, increasing diameter increased the maximum angles of both adduction (+1° ± 1°; P = .03) and abduction (+8° ± 9°; P < .05). Lateralization also increased abduction range of motion compared with neutral (P < .01). Although increasing glenosphere diameter significantly increased joint load and deltoid force, the clinical impact of these changes is presently unclear. Internal rotation, however, was reduced, which contradicts previous bone modeling studies, which we postulate is due to increased posterior capsular tension as it is forced to wrap around a larger 42 mm implant assembly. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Small diameter symmetric networks from linear groups

    Science.gov (United States)

    Campbell, Lowell; Carlsson, Gunnar E.; Dinneen, Michael J.; Faber, Vance; Fellows, Michael R.; Langston, Michael A.; Moore, James W.; Multihaupt, Andrew P.; Sexton, Harlan B.

    1992-01-01

    In this note is reported a collection of constructions of symmetric networks that provide the largest known values for the number of nodes that can be placed in a network of a given degree and diameter. Some of the constructions are in the range of current potential engineering significance. The constructions are Cayley graphs of linear groups obtained by experimental computation.

  1. Changing the Diameter of a Viewing Tube

    Science.gov (United States)

    Obara, Samuel

    2009-01-01

    This article is about the students' investigation about the relationship between the diameter of the view tubes (x) of constant lengths and the viewable vertical distance (y) on the wall while keeping the perpendicular distance from the eyeball to the wall constant. The students collected data and used and represented it in tabular and graphical…

  2. Height - Diameter predictive equations for Rubber (Hevea ...

    African Journals Online (AJOL)

    BUKOLA

    They proffer logistic data for modeling and futuristic prediction for sustainable forest management. Diameter is one of the most ... in various quantitative estimation following the intricacy of time, availability of modern equipments .... growth functions. This trend is shown in Figure 1 where the prediction equations are plotted.

  3. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates.

    Science.gov (United States)

    Nickenig, Hans-Joachim; Eitner, Stephan

    2007-01-01

    We assessed the reliability of implant placement after virtual planning of implant positions using cone-beam CT data and surgical guide templates. A total of 102 patients (250 implants, 55.4% mandibular; mean patient age, 40.4 years) who had undergone implant treatment therapy in an armed forces dental clinic (Cologne, Germany) between July 1, 2005 and December 1, 2005. They were treated with a system that allows transfer of virtual planning to surgical guide templates. Only in eight cases the surgical guides were not used because a delayed implant placement was necessary. In four posterior mandibular cases, handling was limited because of reduced interocclusal distance, requiring 50% shortening of the drill guides. The predictability of implant size was high: only one implant was changed to a smaller diameter (because of insufficient bone). In all cases, critical anatomical structures were protected and no complications were detected in postoperative panoramic radiographs. In 58.1% (147) of the 250 implants, a flapless surgery plan was realized. Implant placement after virtual planning of implant positions using cone beam CT data and surgical templates can be reliable for preoperative assessment of implant size, position, and anatomical complications. It is also indicative of cases amenable to flapless surgery.

  4. A three-dimensional finite element analysis of a passive and friction fit implant abutment interface and the influence of occlusal table dimension on the stress distribution pattern on the implant and surrounding bone

    Directory of Open Access Journals (Sweden)

    Hasan Sarfaraz

    2015-01-01

    Conclusion : It can thus be concluded that the conical connection distributes more stress to the implant body and dissipates less stress to the surrounding bone. A narrow occlusal table considerably reduces the occlusal overload.

  5. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  6. Incidence and impact of prosthesis-patient mismatch after transcatheter aortic valve implantation.

    Science.gov (United States)

    Bleiziffer, Sabine; Hettich, Ina; Hutter, Andrea; Wagner, Anke; Deutsch, Marcus-André; Piazza, Nicolo; Lange, Rüdiger

    2013-05-01

    The study aim was to investigate the incidence of patient-prosthesis mismatch (PPM) with new catheter valves, and its influence on the patients' clinical state. At present, few echocardiographic data are available on the incidence and impact of PPM with the CoreValve and Sapien prostheses for transcatheter aortic valve implantation (TAVI). The reliability of effective orifice area (EOA) measurements was assured by awaiting an interval of six months after TAVI. Of 256 survivors after TAVI, 149 complete echocardiographic data sets were available for the assessment of the indexed EOA (iEOA). In total, 106 CoreValve prostheses and 43 Sapien prostheses were implanted in this high-risk cohort (mean age 81 +/- 6 years, mean logistic EuroSCORE 20 +/- 13%). The overall incidence of PPM (iEOA body surface area were more likely to develop PPM (p = 0.001), while the prosthesis type, native annulus diameter, preoperative EOA, gender and prosthesis size had no influence. The mean aortic gradient was significantly higher in patients with PPM. A reduction in the left ventricular end-diastolic diameter was seen in all patients, without significant differences between groups. There were no differences in postoperative NYHA class or self-assessed health state between patients with or without PPM. PPM was common after TAVI in the presented cohort, presumably because the native calcium masses narrow the outflow area available for blood flow. As expected for low gradients, there was no impairment of left ventricular dimension regression or clinical state of the patients, even if severe PPM was present. Based on the presented data, it is assumed that PPM might be less relevant in TAVI patients.

  7. Volume dips; spot price ranges narrow

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    This article is the September 1994 uranium market summary. Volume in the spot concentrates market fell below 1 million lbs U3O8. In total, twelve deals took place compared to 28 deals in August. Of the twelve deals, three took place in the spot concentrates market, two took place in the medium and long-term market, three in the conversion market, and four in the enrichment market. Restricted prices weakened, but unrestricted prices firmed slightly. The enrichment price range narrowed a bit

  8. f-band narrowing in uranium intermetallics

    International Nuclear Information System (INIS)

    Dunlap, B.D.; Litterst, F.J.; Malik, S.K.; Kierstead, H.A.; Crabtree, G.W.; Kwok, W.; Lam, D.J.; Mitchell, A.W.

    1987-01-01

    Although the discovery of heavy fermion behavior in uranium compounds has attracted a great deal of attention, relatively little work has been done which is sufficiently systematic to allow an assessment of the relationship of such behavior to more common phenomena, such as mixed valence, narrow-band effects, etc. In this paper we report bulk property measurements for a number of alloys which form a part of such a systematic study. The approach has been to take relatively simple and well-understood materials and alter their behavior by alloying to produce heavy fermion or Kondo behavior in a controlled way

  9. Itinerant ferromagnetism in the narrow band limit

    CERN Document Server

    Liu, S H

    2000-01-01

    It is shown that in the narrow band, strong interaction limit the paramagnetic state of an itinerant ferromagnet is described by the disordered local moment state. As a result, the Curie temperature is orders of magnitude lower than what is expected from the large exchange splitting of the spin bands. An approximate analysis has also been carried out for the partially ordered state, and the result explains the temperature evolvement of the magnetic contributions to the resistivity and low-energy optical conductivity of CrO sub 2.

  10. Critical unpairing currents in narrow niobium films

    International Nuclear Information System (INIS)

    Gershenzon, M.E.; Gubankov, V.N.

    1979-01-01

    Investigated are the dependences of critical currents of narrow ( with the width of W=0.5-15 μm) superconducting niobium films on temperature and a magnetic field. The proposed method of film production with the width of the 1μm order and with small edge inhomogeneities ((<=500 A) permitted to realize the Ginsburg-Landau unpairing currents in the wide range of temperatures. The correct comparison with the theory showed that the unpairing currents are observed if W(< or approximately) 2delta, where delta is the effective depth of the penetration of the perpendicular magnetic field

  11. Narrow electron injector for ballistic electron spectroscopy

    International Nuclear Information System (INIS)

    Kast, M.; Pacher, C.; Strasser, G.; Gornik, E.

    2001-01-01

    A three-terminal hot electron transistor is used to measure the normal energy distribution of ballistic electrons generated by an electron injector utilizing an improved injector design. A triple barrier resonant tunneling diode with a rectangular transmission function acts as a narrow (1 meV) energy filter. An asymmetric energy distribution with its maximum on the high-energy side with a full width at half maximum of ΔE inj =10 meV is derived. [copyright] 2001 American Institute of Physics

  12. Narrow-Bicliques: Cryptanalysis of Full IDEA

    DEFF Research Database (Denmark)

    Khovratovich, D.; Leurent, G.; Rechberger, C.

    2012-01-01

    We apply and extend the recently introduced biclique framework to IDEA and for the first time describe an approach to noticeably speed-up key-recovery for the full 8.5 round IDEA.We also show that the biclique approach to block cipher cryptanalysis not only obtains results on more rounds, but also...... extended with ways to allow for a significantly reduced data complexity with everything else being equal. For this we use available degrees of freedom as known from hash cryptanalysis to narrow the relevant differential trails. Our cryptanalysis is of high computational complexity, and does not threaten...

  13. Tree diameter at breast height in relation to stump diameter by species group

    Science.gov (United States)

    Arthur G. Horn; Richard C. Keller

    1957-01-01

    A stump tally is one method of determining the volume of timber previously removed from an area in a logging operation. To estimate volume of standing timber from stumps, foresters must first know the relationship between stump diameters and tree diameters at breast height (d.b.h.).

  14. The vascularization of a gastric tube as a substitute for the esophagus is affected by its diameter.

    Science.gov (United States)

    Pierie, J P; de Graaf, P W; van Vroonhoven, T J; Obertop, H

    1998-10-01

    The stomach is used for reconstruction of the upper gastrointestinal tract after esophageal resection for cancer. The whole stomach can be used, but also a wide or narrow gastric tube can be constructed. Short-term functional results are superior after use of a narrow tube. Healing of the cervical esophagogastrostomy can be impaired, leading to leakage and stricture. The decreased vascularization at the site of the anastomosis may be one reason. It was hypothesized that the quality of the vascularization of the gastric tube, used as a substitute for the oesophagus after esophagectomy, depends on its diameter. The vascularization of postmortem specimens was studied using angiography. Whole stomachs (3), wide (3) and narrow gastric tubes (3) were constructed. In a patient with an anastomotic stricture of a narrow tube with a cervical esophagogastrostomy vascularisation was evaluated by angiography. After infusion of contrast through the supplying arteries, the whole stomachs and wide gastric tubes showed adequate vascularization, whereas the narrow gastric tube showed poor vascularization especially at the site of the anastomosis. In narrow gastric tubes, the right gastroepiploic artery was the only feeding artery. In the patient's angiography, a limited contrast visualization of the proximal end of the gastric tube could be demonstrated. Although a narrow gastric tube is favoured by some surgeons, the use of whole stomach or a type of gastric tube with preservation of the right gastric artery may lead to a better anastomotic healing.

  15. Individual titanium zygomatic implant

    Science.gov (United States)

    Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.

    2018-03-01

    Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.

  16. Alternative approach for management of an electrical storm in Brugada syndrome:Importance of primary ablation within a narrow time window

    Directory of Open Access Journals (Sweden)

    Ahmed Karim Talib, MD, PhD

    2016-06-01

    Full Text Available Placement of an implantable cardioverter–defibrillator (ICD is the only powerful treatment modality for Brugada syndrome in patients presenting with ventricular fibrillation (VF. For those whose first presentation is an electrical storm, pharmacologic therapy is typically used to control VF followed by ICD implantation. We report an alternative approach whereby, before ICD implantation, emergency catheter ablation of the VF-triggering premature ventricular contraction (PVC resulted in long-term VF-free survival. The results suggest that, because VF triggers appear in a narrow time window, ablation of the culprit PVCs that initiate VF before the index PVCs subside is a reasonable alternative approach.

  17. [In hospital and mid-term outcome of patients with NIR stent implantation: multicenter ESPORT-NIR registry].

    Science.gov (United States)

    Iñiguez, A; García, E; Seabra, R; Bordes, P; Bethencourt, A; Rigla, J

    2001-05-01

    Despite improvements in the results and techniques of catheter-based revascularization, few studies have evaluated the clinical results of the application of new stent designs. We describe the in-hospital and mid-term outcome of patients undergoing a stent NIR implantation. At least 1 Stent NIR was implanted in 1.004 patients (1.136 lesions) recruited from 50 centers in an international, multicenter, prospective, registry (Spain and Portugal NIR stent registry). Inclusion criteria were objective coronary ischemia related to a severe de novo lesion or first restenosis in native vessels with a reference diameter >= 2.75 mm. The primary end-point was the incidence of major adverse cardiac events within the first 7 months of follow-up. The mean age of the patients was 60 years and 82% were male. Angioplasty was indicated due to unstable angina in 61% of the cases. Stent implantation was successfully achieved in 99.6%. Clinical success (angiographic success without in-hospital major events) was achieved in 98.6% of patients. The rate of angiographic restenosis (> 50% stenosis narrowing) was 16% (CI 95%; 11.7-21.2). The accumulated major cardiac adverse event rate at seven months of follow-up was 8.7%: death (0.9%), acute myocardial infarction (1.2%) and target lesion revascularization (6.6%). In the wide setting of the population included in the ESPORT-NIR registry, stent NIR implantation was a highly effective therapy with a good mid-term clinical and angiographic outcome.

  18. The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: A three-dimensional finite element analysis.

    Science.gov (United States)

    Topkaya, Tolga; Solmaz, Murat Yavuz

    2015-07-16

    The present study evaluated the effects of ball anchor abutment attached to implants with a 4.30 mm diameter and 11 mm insert length on stress distribution in a patient without any remaining teeth in the lower jaw. In the study, the stress analysis was performed for five different configurations (2 with 4 implant-supported and 3 with 2 implant-supported) and three different loading types using ANSYS Workbench software. The stresses measured in the 4 implant-supported models were lower compared to the stresses measured in the 2 implant-supported models. The stresses on the implants intensified on the cervical region of the implants. When the effects of the loading sites on the stress were examined, the loading on the first molar tooth produced the highest stresses on the implants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla

    Directory of Open Access Journals (Sweden)

    Shrikar R Desai

    2013-01-01

    Full Text Available Aim: The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. Materials and Methods: A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45° to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. Results: The results of total deformation (micro-movement and Von mises stress were found to be lower for tapered long implant (10 mm than short implant (6 mm while using both vertical as well as oblique loading. Conclusion: Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  20. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

    Science.gov (United States)

    Desai, Shrikar R; Singh, Rika; Karthikeyan, I

    2013-09-01

    The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  1. Narrow field electromagnetic sensor system and method

    International Nuclear Information System (INIS)

    McEwan, T.E.

    1996-01-01

    A narrow field electromagnetic sensor system and method of sensing a characteristic of an object provide the capability to realize a characteristic of an object such as density, thickness, or presence, for any desired coordinate position on the object. One application is imaging. The sensor can also be used as an obstruction detector or an electronic trip wire with a narrow field without the disadvantages of impaired performance when exposed to dirt, snow, rain, or sunlight. The sensor employs a transmitter for transmitting a sequence of electromagnetic signals in response to a transmit timing signal, a receiver for sampling only the initial direct RF path of the electromagnetic signal while excluding all other electromagnetic signals in response to a receive timing signal, and a signal processor for processing the sampled direct RF path electromagnetic signal and providing an indication of the characteristic of an object. Usually, the electromagnetic signal is a short RF burst and the obstruction must provide a substantially complete eclipse of the direct RF path. By employing time-of-flight techniques, a timing circuit controls the receiver to sample only the initial direct RF path of the electromagnetic signal while not sampling indirect path electromagnetic signals. The sensor system also incorporates circuitry for ultra-wideband spread spectrum operation that reduces interference to and from other RF services while allowing co-location of multiple electronic sensors without the need for frequency assignments. 12 figs

  2. Dosimetry of narrow band UVB treatments

    International Nuclear Information System (INIS)

    Goode, D.H.; Mannering, D.M.

    1996-01-01

    Full text: For many years psoriasis has been treated with broad band UVB lamps. These lamps have a bell shaped spectrum which peaks at 305 nm and extends from 280 nm to 350 nm. However research with monochromatic UV radiation has shown that wavelengths between 300 nm and 320 nm are the most efficacious for clearing psoriasis while wavelengths below 305 nm are most effective for producing the undesirable side effect of erythema (sunburn). In response to these findings Philips developed a narrow band UVB tube in which a large fraction of the output was confined to a narrow peak (bandwidth 2.5 nm) situated at 311 nm. Christchurch Hospital replaced broad band UVB with narrow band treatments in August 1995 and as this required UV exposures to be substantially increased new protocols had to be developed. Three aspects needed to be addressed. These were translating the dose from broad band to narrow band for current patients, determining the initial dose for new patients and developing a formula for increasing subsequent exposures to both types of patient. To translate doses the spectral irradiance (μW/cm 2 /nm) that would fall on the patient was measured in both the old broad band and the new narrow band treatment units and from this UV doses were calculated. All doses were expressed in mJ/cm 2 of unweighted UV over the range 250 nm to 400 nm. The erythemal effectiveness of the two units were compared by using the CIE 1987 curve to express doses in terms of the equivalent exposure of monochromatic 297 nm radiation. It was found that an exposure of 3.96 mJ/cm 2 from the broad band FS40 tubes and 12.79 mJ/cm 2 from the narrow band TL/01 tubes were both equivalent to 1.00 mJ/cm 2 of monochromatic 297 nm radiation so when transferring patients all broad band doses needed to be increased by a factor of 3.2. Before transferring any patients this factor was confirmed by conducting two minimal erythema dose (MED) tests on a normal subject, one in each unit. For new patients a

  3. A methodology to enlarge narrow stability windows

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Ewerton M.P.; Pastor, Jorge A.S.C.; Fontoura, Sergio A.B. [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. de Engenharia Civil. Grupo de Tecnologia e Engenharia de Petroleo

    2004-07-01

    The stability window in a wellbore design is defined by the difference between fracture pressure and collapse pressure. Deep water environments typically present narrow stability windows, because rocks have low strength due to under-compaction process. Often also, horizontal wells are drilled to obtain a better development of reservoirs placed in thin layers of sandstone. In this scenario, several challenges are faced when drilling in deep water. The traditional approach for predicting instabilities is to determine collapses and fractures at borehole wall. However, the initiation of rupture does not indicate that the borehole fails to perform its function as a wellbore. Thus, a methodology in which the stability window may be enlarged is desirable. This paper presents one practical analytical methodology that consists in allowing wellbore pressures smaller than the conventional collapse pressure, i.e., based upon failure on the borehole wall. This means that a collapse region (shear failure) will be developed around the borehole wall. This collapse region is pre-defined and to estimate its size is used a failure criterion. The aforementioned methodology is implemented in a user-friendly software, which can perform analyses of stress, pore pressure, formation failure, mud weight and mud salinity design for drilling in shale formations. Simulations of a wellbore drilling in a narrow stability window environment are performed to demonstrate the improvements of using the methodology. (author)

  4. Narrow resonances and short-range interactions

    International Nuclear Information System (INIS)

    Gelman, Boris A.

    2009-01-01

    Narrow resonances in systems with short-range interactions are discussed in an effective field theory (EFT) framework. An effective Lagrangian is formulated in the form of a combined expansion in powers of a momentum Q 0 | 0 --a resonance peak energy. At leading order in the combined expansion, a two-body scattering amplitude is the sum of a smooth background term of order Q 0 and a Breit-Wigner term of order Q 2 (δε) -1 which becomes dominant for δε 3 . Such an EFT is applicable to systems in which short-distance dynamics generates a low-lying quasistationary state. The EFT is generalized to describe a narrow low-lying resonance in a system of charged particles. It is shown that in the case of Coulomb repulsion, a two-body scattering amplitude at leading order in a combined expansion is the sum of a Coulomb-modified background term and a Breit-Wigner amplitude with parameters renormalized by Coulomb interactions.

  5. Inhibited Bacterial Adhesion and Biofilm Formation on Quaternized Chitosan-Loaded Titania Nanotubes with Various Diameters

    Directory of Open Access Journals (Sweden)

    Wen-tao Lin

    2016-03-01

    Full Text Available Titania nanotube-based local drug delivery is an attractive strategy for combating implant-associated infection. In our previous study, we demonstrated that the gentamicin-loaded nanotubes could dramatically inhibit bacterial adhesion and biofilm formation on implant surfaces. Considering the overuse of antibiotics may lead to the evolution of antibiotic-resistant bacteria, we synthesized a new quaternized chitosan derivative (hydroxypropyltrimethyl ammonium chloride chitosan, HACC with a 27% degree of substitution (DS; referred to as 27% HACC that had a strong antibacterial activity and simultaneously good biocompatibility with osteogenic cells. Titania nanotubes with various diameters (80, 120, 160, and 200 nm and 200 nm length were loaded with 2 mg of HACC using a lyophilization method and vacuum drying. Two standard strain, methicillin-resistant Staphylococcus aureus (American Type Culture Collection 43300 and Staphylococcus epidermidis (American Type Culture Collection 35984, and two clinical isolates, S. aureus 376 and S. epidermidis 389, were selected to investigate the bacterial adhesion at 6 h and biofilm formation at 24, 48, and 72 h on the HACC-loaded nanotubes (NT-H using the spread plate method, confocal laser scanning microscopy (CLSM, and scanning electron microscopy (SEM. Smooth titanium (Smooth Ti was also investigated and compared. We found that NT-H could significantly inhibit bacterial adhesion and biofilm formation on its surface compared with Smooth Ti, and the NT-H with 160 nm and 200 nm diameters had stronger antibacterial activity because of the extended HACC release time of NT-H with larger diameters. Therefore, NT-H can significantly improve the antibacterial ability of orthopedic implants and provide a promising strategy to prevent implant-associated infections.

  6. DESIGN OF PARTICULATE MATERIAL COMPACTOR ROLLS DIAMETER

    Directory of Open Access Journals (Sweden)

    Peter Peciar

    2017-09-01

    Full Text Available At present, in a period of an industrial expansion great emphasis is placed on the environment. That means aiming for a reduced energy consumption, and also lessening dustiness from very fine powder material. This category also includes particulate material agglomeration processes. Because this process is very energy-intensive, it is necessary to correctly design these devices. The aim of this paper is to focus on a theoretical design of a production compactor with the rolls diameter for an experimental particulate material, based on Johanson’s theory and experimentally measured material properties. The material used for experimental measurements was an NPK-based industrial fertilizer consisting of several components. The results of this paper is the dependence of the ratio of the maximum compression pressure to the initial compression pressure from the rolls diameter of the proposed compactor.

  7. The influence of upper airways diameter on the intensity of obstructive sleep apnea

    Directory of Open Access Journals (Sweden)

    Jolanta Szymańska

    2014-03-01

    Full Text Available Introduction and Objective. Obstructive sleep apnea (OSA is characterized by at least 5 ten-second-long episodes of apnea or hypopnea, per hour of sleep. This disease may lead to severe, life-threatening complications. Therefore, risk analysis and its influence on disease intensity is crucial for proper implementation of preventive treatments. Objective. To determine the relation between the intensity of OSA expressed in Apnea-Hypopnea Index (AHI, and the anterior-posterior diameter of upper airways at the levels of soft palate and tongue base. Material and Method. Medical records of 41 patients with sleep apnea (AHI>4 diagnosed through polysomnographic examination obstructive were used for the study. The data consisted of: age and gender, polysomnographic examination results (AHI, lateral cephalogram with cephalomertic analysis, together with measurements of the upper and lower pharyngeal depth according to McNamara. Statistical analysis was carried out in accordance with Pearson’s r correlation coefficient test (Statistica 8.0 software package. Results. Analysis of the influence of upper airways diameter on the intensity of OSA showed that the value of upper Airways diameter at the tongue base level had no statistically significant impact on the value of AHI (p=0.795. However, a statistically significant impact of the value of upper airways diameter on the AHI value (p=0.008 at the soft palate level was observed. Patients with OSA have narrowed upper airways diameter. The value of AHI increases with the decrease of upper diameter and is not dependent on a lower diameter value. Patients with a decreased upper airways diameter should be informed about potential breathing disorders during sleep.

  8. Device for guiding various diameter size cable

    Energy Technology Data Exchange (ETDEWEB)

    Litvinov, I.M.; Klauzer, L.P.; Yeganov, L.I.; Zaripov, A.M.

    1982-01-30

    A design is submitted for a device to guide cable of various diameters. This device consists of a profiled multiple-pass roller, and clamps for uniting cut cable. This design is simplified by allowing both the rollers and their supports to rotate on the roller axis thus facilitating interaction with the clamps. The working surface of the supports is evolute while the outside surfaces have screw-channels for transfering the cable from one roller pass to the other.

  9. Retrospective analysis of 56 edentulous dental arches restored with 344 single-stage implants using an immediate loading fixed provisional protocol: statistical predictors of implant failure.

    Science.gov (United States)

    Kinsel, Richard P; Liss, Mindy

    2007-01-01

    The purpose of this retrospective study was to evaluate the effects of implant dimensions, surface treatment, location in the dental arch, numbers of supporting implant abutments, surgical technique, and generally recognized risk factors on the survival of a series of single-stage Straumann dental implants placed into edentulous arches using an immediate loading protocol. Each patient received between 4 and 18 implants in one or both dental arches. Periapical radiographs were obtained over a 2- to 10-year follow-up period to evaluate crestal bone loss following insertion of the definitive metal-ceramic fixed prostheses. Univariate tests for failure rates as a function of age ( or = 60 years), gender, smoking, bone grafting, dental arch, surface type, anterior versus posterior, number of implants per arch, and surgical technique were made using Fisher exact tests. The Cochran-Armitage test for trend was used to evaluate the presence of a linear trend in failure rates regarding implant length and implant diameter. Logistic regression modeling was used to determine which, if any, of the aforementioned factors would predict patient and implant failure. A significance criterion of P = .05 was utilized. Data were collected for 344 single-stage implants placed into 56 edentulous arches (39 maxillae and 17 mandibles) of 43 patients and immediately loaded with a 1-piece provisional fixed prosthesis. A total of 16 implants failed to successfully integrate, for a survival rate of 95.3%. Increased rates of failure were associated with reduced implant length, placement in the posterior region of the jaw, increased implant diameter, and surface treatment. Implant length emerged as the sole significant predictor of implant failure. In this retrospective analysis of 56 consecutively treated edentulous arches with multiple single-stage dental implants loaded immediately, reduced implant length was the sole significant predictor of failure.

  10. Implantation rate effects on microstructure

    International Nuclear Information System (INIS)

    Choyke, W.J.; Spitznagel, J.A.; Wood, S.; Doyle, N.J.

    1981-01-01

    We report a detailed TEM study of rate effects in a metal (304 SS) where we dope with an insoluble atom (He) and create the displacement damage with high energy Si. The rates of doping and the rates of producing lattice damage are independently varied during dual implantation. In addition to varying the doping rates of the He the magnitude of the displacement damage prior to He implantation is also varied (beam history). We find that the beam history has virtually no effect on maximum bubble size but it has a major effect on the average cavity diameter. A weak dependence of cavity number density on helium implantation rate is found. The total dislocation density is relatively independent of the doping rate and beam history at 550 and 700 0 C, whereas the loop fraction is sensitive to beam history at these temperatures. Acicular precipitate formation is weakly dependent on doping, doping rate and more strongly dependent on doping concentration and temperature. This form of solute segregation is very sensitive to beam history. (orig.)

  11. Implant stability and marginal bone level of microgrooved zirconia dental implants: A 3-month experimental study on dogs

    Directory of Open Access Journals (Sweden)

    Delgado-Ruíz Rafael Arcesio

    2014-01-01

    Full Text Available Background/Aim. The modification of implant surfaces could affect mechanical implant stability as well as dynamics and quality of peri-implant bone healing. The aim of this 3-month experimental study in dogs was to investigate implant stability, marginal bone levels and bone tissue response to zirconia dental implants with two laser-micro-grooved intraosseous surfaces in comparison with nongrooved sandblasted zirconia and sandblasted, high-temperature etched titanium implants. Methods. Implant surface characterization was performed using optical interferometric profilometry and energy dispersive X-ray spectroscopy. A total of 96 implants (4 mm in diameter and 10 mm in length were inserted randomly in both sides of the lower jaw of 12 Fox Hound dogs divided into groups of 24 each: the control (titanium, the group A (sandblasted zirconia, the group B (sandblasted zirconia plus microgrooved neck and the group C (sandblasted zirconia plus all microgrooved. All the implants were immediately loaded. Insertion torque, periotest values, radiographic crestal bone level and removal torque were recorded during the 3-month follow-up. Qualitative scanning electon micro-scope (SEM analysis of the bone-implant interfaces of each group was performed. Results. Insertion torque values were higher in the group C and control implants (p the control > the group B > the group A (p the control > the group B > the group A (p < 0.05. SEM showed that implant surfaces of the groups B and C had an extra bone growth inside the microgrooves that corresponded to the shape and direction of the microgrooves. Conclusion. The addition of micro-grooves to the entire intraosseous surface of zirconia dental implants enhances primary and secondary implant stability, promotes bone tissue ingrowth and preserves crestal bone levels.

  12. Analysis of narrow effects in pp annihilations

    CERN Document Server

    Defoix, C

    1972-01-01

    The author describes briefly some methods of analysis that final states involving a number of like particles require. A first method consists of separating two competing channels to minimize the reflections due to the undesirable one. Later techniques of analysis lead to the isolation of the only channel of interest and circumvention of the problems of background and reflections due to irrelevant final states. Generally, all these processes are based on the presence of a narrow and identified resonance, for example the eta /sup 0/ or omega /sup 0/ ( to pi /sup +/ pi /sup -/ pi /sup 0/). To be efficient, it is necessary that the observed width of such a basic resonance not be increased too much by experimental errors. (6 refs).

  13. Search for narrow four-baryon states

    International Nuclear Information System (INIS)

    Badelek, B.

    1981-01-01

    Highly excited (4.10 2 ) four-baryon resonances have been searched for in the missing-mass spectrum of the reaction π - + 4 He → π - + X at 5 GeV/c in the region of small four-momentum transfer (0.005 2 ), where one of the decay products of the X is either proton or deuteron or triton. No resonance signal is seen in the mass spectrum of X. Within our limited acceptance, the cross section for the production of a narrow (GAMMA approx. 20 MeV/c 2 ) four-baryon state with mass 4.9 GeV/c 2 is estimated to be smaller than approx. 100 nb. (orig.)

  14. Active Brownian motion in a narrow channel

    Science.gov (United States)

    Ao, X.; Ghosh, P. K.; Li, Y.; Schmid, G.; Hänggi, P.; Marchesoni, F.

    2014-12-01

    We review recent advances in rectification control of artificial microswimmers, also known as Janus particles, diffusing along narrow, periodically corrugated channels. The swimmer self-propulsion mechanism is modeled so as to incorporate a nonzero torque (propulsion chirality). We first summarize the effects of chirality on the autonomous current of microswimmers freely diffusing in channels of different geometries. In particular, left-right and upside-down asymmetric channels are shown to exhibit different transport properties. We then report new results on the dependence of the diffusivity of chiral microswimmers on the channel geometry and their own self-propulsion mechanism. The self-propulsion torque turns out to play a key role as a transport control parameter.

  15. Retinal vessel diameters decrease with macular ganglion cell layer thickness in autosomal dominant optic atrophy and in healthy subjects

    DEFF Research Database (Denmark)

    Rönnbäck, Cecilia; Grønskov, Karen; Larsen, Michael

    2014-01-01

    diameters (central retinal artery equivalent, CRAE, and central retinal vein equivalent, CRVE). Statistical analysis was corrected for age, gender, spherical equivalent refraction, axial length and mean arterial blood pressure (MABP) in a mixed model analysis. RESULTS: Retinal arteries and veins were...... ganglion cell-inner plexiform layer (GC-IPL) thickness (p = 0.0017 and p = 0.0057, respectively). CONCLUSION: Narrow retinal arteries and veins were associated not only with the severity of ADOA but with ganglion cell volume in patients with ADOA and in healthy subjects. This suggests that narrow vessels...

  16. The efficacy of short (6 mm) dental implants with a novel thread design.

    Science.gov (United States)

    Bechara, Soheil; Nimčenko, Tatjana; Kubilius, Ričardas

    2017-01-01

    To assess efficacy of short (6 mm) implants with a novel macrostructure and thread design placed in a compromised bone situations of edentulous posterior regions of maxilla (3-4 mm of bone height under sinus floor) as compared to results of clinical situations treated with simultaneous maxillary sinus grafting and placement of long (≥10 mm) implants of the same company. Clinical cases of conducted clinical study. Patients with compromised bone height in edentulous posterior regions of maxilla were randomly divided into two groups. Short (6mm length) implant treatment conducted in the test group and simultaneous sinus lift with standard length implant placement treatment in the control group. In general implant stability quotient (ISQ) and marginal bone level (MBL) changes values in both groups were comparable. However, significant negative correlation was found between implant's diameter and MBL changes. Implant's length has little if none impact on initial implant anchorage, especially in greatly compromised residual bone situations. Results have confirmed that implant initial stability mainly depends on implant's macro-design and further its development on implant's micro-design: namely, implant diameter rather than length, tapered shape and improved thread design determines primarily acquired mechanical anchorage, while bioactive surface treatment ensures development of biological stability.

  17. Effect of Dissolved gas on bubble behavior of subcooled boiling in narrow channel

    International Nuclear Information System (INIS)

    Li Shaodan; Tan Sichao; Xu Chao; Gao Puzhen; Xu Jianjun

    2013-01-01

    An experimental investigation was performed to study the effect of dissolved gas on bubble behavior in narrow rectangular channel under subcooled boiling condition. A high-speed digital video camera was applied to capture the dynamics of the bubble with or without dissolved gas in a narrow rectangular channel. It is found that the dissolved gas has great influence on bubble behavior in subcooled boiling condition. The dissolved gas slows down the rate of bubble growth and condensation and makes the variation of the bubble diameter present some oscillation characteristics. This phenomenon was discussed in the view of the vapor evaporation and condensation. The existence of the dissolved gas can facilitate the survival of the bubble and promote the aggregation of bubbles, and enhence heat transfer enhancement in some ways. (authors)

  18. An experimental study on critical heat flux in a hemispherical narrow gap

    International Nuclear Information System (INIS)

    Park, R.J.; Lee, S.J.; Kang, K.H.; Kim, J.H.; Kim, S.B.; Kim, H.D.; Jeong, J.H.

    2000-01-01

    An experimental study of CHFG (Critical Heat Flux in Gap) has been performed to investigate the inherent cooling mechanism using distilled water and Freon R-113 in hemispherical narrow gaps. As a separate effect test of the CHFG test, a CCFL (Counter Current Flow Limit) test has been also performed to confirm the mechanism of the CHF in narrow annular gaps with large diameter. The CHFG test results have shown that an increase in the gap thickness leads to an increase in critical power. The pressure effect on the critical power was found to be much milder than predictions by CHF correlations of other studies. In the CCFL experiment, the occurrence of CCFL was correlated with the Wallis parameter, which was assumed to correspond to the critical power in the CHFG experiment. The measured values of critical power in the CHFG tests are much lower than CCFL experimental data and the predictions made by empirical CHF correlations. (author)

  19. The effect of narrow provider networks on health care use.

    Science.gov (United States)

    Atwood, Alicia; Lo Sasso, Anthony T

    2016-12-01

    Network design is an often overlooked aspect of health insurance contracts. Recent policy factors have resulted in narrower provider networks. We provide plausibly causal evidence on the effect of narrow network plans offered by a large national health insurance carrier in a major metropolitan market. Our econometric design exploits the fact that some firms offer a narrow network plan to their employees and some do not. Our results show that narrow network health plans lead to reductions in health care utilization and spending. We find evidence that narrow networks save money by selecting lower cost providers into the network. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Diameter-dependent hydrophobicity in carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Kyakuno, Haruka, E-mail: h-kyakuno@kanagawa-u.ac.jp [Department of Physics, Graduate School of Science and Engineering, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); Institute of Physics, Faculty of Engineering, Kanagawa University, Yokohama 221-8686 (Japan); Fukasawa, Mamoru; Ichimura, Ryota; Nakai, Yusuke; Maniwa, Yutaka, E-mail: maniwa@phys.se.tmu.ac.jp [Department of Physics, Graduate School of Science and Engineering, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); Matsuda, Kazuyuki [Institute of Physics, Faculty of Engineering, Kanagawa University, Yokohama 221-8686 (Japan); Miyata, Yasumitsu [Department of Physics, Graduate School of Science and Engineering, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); PRESTO, JST, Kawaguchi 332-0012 (Japan); Saito, Takeshi [Nanotube Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8565 (Japan)

    2016-08-14

    Single-wall carbon nanotubes (SWCNTs) are a good model system that provides atomically smooth nanocavities. It has been reported that water-SWCNTs exhibit hydrophobicity depending on the temperature T and the SWCNT diameter D. SWCNTs adsorb water molecules spontaneously in their cylindrical pores around room temperature, whereas they exhibit a hydrophilic-hydrophobic transition or wet-dry transition (WDT) at a critical temperature T{sub wd} ≈ 220-230 K and above a critical diameter D{sub c} ≈ 1.4-1.6 nm. However, details of the WDT phenomenon and its mechanism remain unknown. Here, we report a systematic experimental study involving X-ray diffraction, optical microscopy, and differential scanning calorimetry. It is found that water molecules inside thick SWCNTs (D > D{sub c}) evaporate and condense into ice Ih outside the SWCNTs at T{sub wd} upon cooling, and the ice Ih evaporates and condenses inside the SWCNTs upon heating. On the other hand, residual water trapped inside the SWCNTs below T{sub wd} freezes. Molecular dynamics simulations indicate that upon lowering T, the hydrophobicity of thick SWCNTs increases without any structural transition, while the water inside thin SWCNTs (D < D{sub c}) exhibits a structural transition, forming an ordered ice. This ice has a well-developed hydrogen bonding network adapting to the cylindrical pores of the SWCNTs. Thus, the unusual diameter dependence of the WDT is attributed to the adaptability of the structure of water to the pore dimension and shape.

  1. Retrobulbar diameter of optic nerve in glaucoma

    Directory of Open Access Journals (Sweden)

    Stefanović Ivan

    2009-01-01

    Full Text Available Introduction. The ultrasound diagnostics of the optic nerve includes the analysis of the optic nerve disc (PNO and measuring of its retrobulbar diameter. With B-scan, by Schraeder's method, it is possible to measure very precisely the optic nerve, the pial diameter, the normal values for the pial diameter being 2.8-4.1 mm. In glaucoma, the disease that is most frequently associated with higher intraocular pressure, there comes the destruction of nerve fibres, which can be visualized as the excavation of the optic nerve disc. Objective. In this paper, we were interested in finding whether in glaucoma, and in what phase of the disease, the optic nerve starts growing thinner. Aware of many forms of this very complex disease, we were interested in knowing if the visualization of excavation on the optic nerve disc is related to diminishing of the pial diameter of the retrobulbar nerve part. Methods. There were treated the patients who had already had the diagnosis of glaucoma and the visualized excavation of the optic disc of various dimensions. Echographically, there was measured the thickness of the retrobulbar part of the optic nerve and the finding compared in relation to the excavation of the optic disc. Results. In all eyes with glaucoma, a normal size of the retrobulbar part of the optic nerve was measured, ranging from 3.01 to 3.91 mm with the median of 3.36 mm. Also, by testing the correlation between the thickness of the optic nerve and the excavation of the PNO, by Pearson test, we found that there was no correlation between these two parameters (r=0.109; p>0.05. Conclusion. In the patients with glaucoma, the retrobulbar part of the optic nerve is not thinner (it has normal values, even not in the cases with a totally excavated optic disc. There is no connection between the size of the PNO excavation and the thickness of the retrobulbar part of the optic nerve.

  2. 29 mm Diameter Target Test Report

    Energy Technology Data Exchange (ETDEWEB)

    Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Olivas, Eric Richard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Naranjo, Angela Carol [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States); Gromov, Roman [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-10-23

    After numerous delays, the test of the 29 mm diameter target was conducted on 8/18/2017. The complete target design report, dated 8/15/2016, is reproduced below for completeness. This describes in detail the 10 disk target with varying thickness disks. The report presents and discusses the test results. In brief summary, there appears to have been multiple instrumentation errors. Measured temperatures, pressures and IR camera window temperature measurement are all suspect. All tests were done at 35 MeV, with 171 μA current, or 6 kW of beam power.

  3. Prosthetic Rehabilitation of a Patient with Mandibular Resection Prosthesis Using Mini Dental Implants (MDIs) – Case Report

    OpenAIRE

    Vojvodić, Denis; Čelebić, Asja; Mehulić, Ketij; Žabarović, Domagoj

    2012-01-01

    Physical disfigurement and functional impairments associated with facial trauma are a challenge to a prosthodontist, because even novel sophisticated surgical reconstructive techniques fail to provide adequate support for dental resection prosthesis. Therefore, different endosseous implants are often used as prosthesis-supporting elements. Manufacturers of dental implants have recently presented mini dental implants (MDIs) with diameter of only 1.8–2.4 mm. These implants allow very suitable p...

  4. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  5. Intercavitary implants dosage calculation

    International Nuclear Information System (INIS)

    Rehder, B.P.

    The use of spacial geometry peculiar to each treatment for the attainment of intercavitary and intersticial implants dosage calculation is presented. The study is made in patients with intercavitary implants by applying a modified Manchester technique [pt

  6. Complete Congenital Heart Block in a Neonatal Lupus Erythematosus Associated with Pulmonary Involvement without Pacemaker Implantation: A Case Report

    Directory of Open Access Journals (Sweden)

    Yazdan Ghandi

    2016-10-01

    Conclusion: This case report was conducted on a newborn with CCHB associated with pulmonary disorder. The newborn was intubated due to respiratory distress and did not need pacemaker implantation; however, after 8-month follow up, excellent outcomes were observed. It seems that atelectasis and mechanical ventilation can intolerance, and pacemaker implantation did not need in NLE with CCHB with narrowing QRS complex.

  7. Sagittal Abdominal Diameter: Application in Clinical Practice

    Directory of Open Access Journals (Sweden)

    Thaís Da Silva-Ferreira

    2014-05-01

    Full Text Available Excess visceral fat is associated with cardiovascular risk factors. Sagittal abdominal diameter (SAD has recently been highlighted as an indicator of abdominal obesity, and also may be useful in predicting cardiovascular risk. The purpose of the present study was to review the scientific literature on the use of SAD in adult nutritional assessment. A search was conducted for scientific articles in the following electronic databases: SciELO , MEDLINE (PubMed and Virtual Health Library. SAD is more associated with abdominal fat (especially visceral, and with different cardiovascular risk factors, such as, insulin resistance, blood pressure, and serum lipoproteins than the traditional methods of estimating adiposity, such as body mass index and waist-to-hip ratio. SAD can also be used in association with other anthropometric measures. There are still no cut-off limits established to classify SAD as yet. SAD can be an alternative measure to estimate visceral adiposity. However, the few studies on this diameter, and the lack of consensus on the anatomical site to measure SAD, are obstacles to establish cut-off limits to classify it.

  8. Usefulness of Tricuspid Annular Diameter to Predict Late Right Sided Heart Failure in Patients With Left Ventricular Assist Device.

    Science.gov (United States)

    Nakanishi, Koki; Homma, Shunichi; Han, Jiho; Takayama, Hiroo; Colombo, Paolo C; Yuzefpolskaya, Melana; Garan, Arthur R; Farr, Maryjane A; Kurlansky, Paul; Di Tullio, Marco R; Naka, Yoshifumi; Takeda, Koji

    2018-07-01

    Although late-onset right-sided heart failure is recognized as a clinical problem in the treatment of patients with left ventricular assist devices (LVADs), the mechanism and predictors are unknown. Tricuspid valve (TV) deformation leads to the restriction of the leaflet motion and decreased coaptation, resulting in a functional tricuspid regurgitation that may act as a surrogate marker of late right-sided heart failure. This study aimed to investigate the association of preoperative TV deformation (annulus dilatation and leaflet tethering) with late right-sided heart failure development after continuous-flow LVAD implantation. The study cohort consisted of 274 patients who underwent 2-dimensional echocardiography before LVAD implantation. TV annulus diameter and tethering distance were measured in an apical 4-chamber view. Late right-sided heart failure was defined as right-sided heart failure requiring readmission and medical and/or surgical treatment after initial LVAD implantation. During a mean follow-up of 25.1 ± 19.0 months after LVAD implantation, late right-sided heart failure occurred in 33 patients (12.0%). Multivariate Cox proportional hazard analysis demonstrated that TV annulus diameter (hazard ratio 1.221 per 1 mm, p right-sided heart failure development, whereas leaflet tethering distance was not. The best cut-off value of the TV annular diameter was 41 mm (area under the curve 0.787). Kaplan-Meier analysis showed that patients with dilated TV annulus (TV annular diameter ≥41 mm) exhibited a significantly higher late right-sided heart failure occurrence than those without TV annular enlargement (log-rank p right-sided heart failure after LVAD implantation. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Optical observations of the nearby galaxy IC342 with narrow band [SII] and Hα filters. I

    Directory of Open Access Journals (Sweden)

    Vučetić M.M.

    2013-01-01

    Full Text Available We present observations of a portion of the nearby spiral galaxy IC342 using narrow band [SII] and Hα filters. These observations were carried out in November 2011 with the 2m RCC telescope at Rozhen National Astronomical Observatory in Bulgaria. In this paper we report coordinates, diameters, Hα and [SII] fluxes for 203 HII regions detected in two fields of view in IC342 galaxy. The number of detected HII regions is 5 times higher than previously known in these two parts of the galaxy. [Projekat Ministarstva nauke Republike Srbije, br. 176005: Emission nebulae: structure and evolution

  10. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  11. Transpedicular fixation for the espondilolistesis treatment, espondilolisis and channel lumbar narrow of the lumbosacral column

    International Nuclear Information System (INIS)

    Matta Javier Ernesto; Diaz, Cesar Jacobo; Gamba S, Cesar Enrique

    2002-01-01

    A descriptive, prospective study was designs with the objective of analyzing the experience with the technique of transpedicular fixation, for the treatment of degenerative espondilolistesis, espondilolisis and channel lumbar narrow. Eighty patients (42 men and 38 women) they were intervened between February of 1992 and February of 2002; the age average was of 46,3 years and the minimum pursuit of 7 months. The cases were tabulated according to the diagnostic, clinical presentation, previous interventions, descompressive procedures associated to the fixation, anatomical level of lesion, number of fixed vertebras, number of placed screws, type of bony implants and complications. In 33 patients (41,3%) it diagnose degenerative espondilolistesis, espondilolisis in 24 (30%), channel lumbar narrow in 20 (25%), displasic espondilolistesis in 2,5% and espondiloptosis in 1%. the clinical presentations more frequent were radicular and lumbar pain, with 33,8 each one; one carries out arthrodesis 15-S1 in 38 patients (47,5%) and 14 15 in 15 patients (18,7%). as complications we find deep infection in 7,5% of the cases, neurological deficit in 5%, rupture of duramadre 3,8%, false route of screws, bony failure and material rupture in 2,5% each one and seroma in 1,3%. Doesn't present seudoarthrosis. The transpedicular fixation is a sure technique for the treatment of the degenerative espondilolistesis, espondilolisis and channel lumbar narrow. With the transpedicular fixation the average of fixed vertebras is smaller than with the Harrington and Luque techniques, preserving in more degree the mobility to articulate. The association of the transpedicular fixation with arthrodesis and coalition by means of placement of autogenous implants diminishes the seudoarthrosis incidence

  12. A 60 keV implanter for metals

    International Nuclear Information System (INIS)

    Leutenecker, R.; Ryssel, H.; Zeller, K.-H.; Spoehrle, H.P.

    1985-01-01

    The design and preliminary performance data of a 60 keV high current implanter for the implantation of non-separated ion beams into metals are described. The target chamber accepts samples up to 70 cm in diameter and is equipped with holders to implant ball bearings, axles and other components which have to be rotated during implantation. Samples are mounted on a rugged table which can move up to 35 kg for +-35 cm in the x and y directions. The implanter, including the vacuum system, is completely computer controlled. The ion source is equipped with an oven having a maximum temperature of 1200 0 C and can deliver ion beams of nitrogen as well as different metal ions such as tin and silver with currents up to 10 mA. (Auth.)

  13. Effect of insertion torque on titanium implant osseointegration: an animal experimental study.

    Science.gov (United States)

    Duyck, Joke; Roesems, Rutger; Cardoso, Marcio V; Ogawa, Toru; De Villa Camargos, Germana; Vandamme, Katleen

    2015-02-01

    To evaluate the effect of implant insertion torque on the peri-implant bone healing and implant osseointegration. Bilaterally in the tibia of five adult New Zealand white rabbits, 20 implants were installed, subdivided into four groups, corresponding to two insertion torque conditions (low, 50 Ncm) and 2 experimental periods (2 weeks vs. 4 weeks of healing). The implant insertion torque was determined by the surgical drill diameter relative to the implant diameter. Implant osseointegration was evaluated by quantitative histology (bone-to-implant contact with host bone [BIC-host], with neoformed bone [BIC-de novo], with both bone types [BIC-total], and peri-implant bone [BA/TA]). Every response was modelled over time using GEE (general estimation equation) with an unstructured variance-covariance matrix to correct for dependency between the measurements from one animal. The statistical significance level of α = 0.05 was applied. Significantly, more BIC-host and BIC-total were recorded for H implants compared with L implants after 2 week of healing (P = 0.010 and P = 0.0001, respectively). However, this result was no longer found for the extended healing period. Furthermore, BIC-total significantly increased over time for L implants (P torque led to an increased BA/TA after 4 week of healing (P torque implants installed in the rabbit tibial bone osseointegrate with considerable de novo bone formation. This bone neoformation enables L implants to catch up, already during the early osseointegration stage, the initial inferior amount BIC contact compared with that of H implants. A negative impact of the created strain environment accompanying H insertion torque implant installation on the biological process of osseointegration could not be observed, at least not at tissue level. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Properties of Narrow line Seyfert 1 galaxies

    Science.gov (United States)

    Rakshit, Suvendu; Stalin, Chelliah Subramonian; Chand, Hum; Zhang, Xue-Guang

    2018-04-01

    Narrow line Seyfert 1 (NLSy1) galaxies constitute a class of active galactic nuclei characterized by the full width at half maximum (FWHM) of the Hα broad emission line 10 pixel-1. A strong correlation between the Hα and Hα emission lines is found both in the FWHM and flux. The nuclear continuum luminosity is found to be strongly correlated with the luminosity of Hα, Hα and [O III] emission lines. The black hole mass in NLSy1 galaxies is lower compared to their broad line counterparts. Compared to BLSy1 galaxies, NLSy1 galaxies have a stronger FeII emission and a higher Eddington ratio that place them in the extreme upper right corner of the R4570 - λEdd diagram. The distribution of the radio-loudness parameter (R) in NLSy1 galaxies drops rapidly at R>10 compared to the BLSy1 galaxies that have powerful radio jets. The soft X-ray photon index in NLSy1 galaxies is on average higher (2.9 ± 0.9) than BLSy1 galaxies (2.4 ± 0.8). It is anti-correlated with the Hα width but correlated with the FeII strength. NLSy1 galaxies on average have a lower amplitude of optical variability compared to their broad lines counterparts. These results suggest Eddington ratio as the main parameter that drives optical variability in these sources.

  15. Thermoelectricity in correlated narrow-gap semiconductors

    Science.gov (United States)

    Tomczak, Jan M.

    2018-05-01

    We review many-body effects, their microscopic origin, as well as their impact on thermoelectricity in correlated narrow-gap semiconductors. Members of this class—such as FeSi and FeSb2—display an unusual temperature dependence in various observables: insulating with large thermopowers at low temperatures, they turn bad metals at temperatures much smaller than the size of their gaps. This insulator-to-metal crossover is accompanied by spectral weight-transfers over large energies in the optical conductivity and by a gradual transition from activated to Curie–Weiss-like behaviour in the magnetic susceptibility. We show a retrospective of the understanding of these phenomena, discuss the relation to heavy-fermion Kondo insulators—such as Ce3Bi4Pt3 for which we present new results—and propose a general classification of paramagnetic insulators. From the latter, FeSi emerges as an orbital-selective Kondo insulator. Focussing on intermetallics such as silicides, antimonides, skutterudites, and Heusler compounds we showcase successes and challenges for the realistic simulation of transport properties in the presence of electronic correlations. Further, we explore new avenues in which electronic correlations may contribute to the improvement of thermoelectric performance.

  16. Thermal tuning On narrow linewidth fiber laser

    Science.gov (United States)

    Han, Peiqi; Liu, Tianshan; Gao, Xincun; Ren, Shiwei

    2010-10-01

    At present, people have been dedicated to high-speed and large-capacity optical fiber communication system. Studies have been shown that optical wavelength division multiplexing (WDM) technology is an effective means of communication to increase the channel capacity. Tunable lasers have very important applications in high-speed, largecapacity optical communications, and distributed sensing, it can provide narrow linewidth and tunable laser for highspeed optical communication. As the erbium-doped fiber amplifier has a large gain bandwidth, the erbium-doped fiber laser can be achieved lasing wavelength tunable by adding a tunable filter components, so tunable filter device is the key components in tunable fiber laser.At present, fiber laser wavelength is tuned by PZT, if thermal wavelength tuning is combined with PZT, a broader range of wavelength tuning is appearance . Erbium-doped fiber laser is used in the experiments,the main research is the physical characteristics of fiber grating temperature-dependent relationship and the fiber grating laser wavelength effects. It is found that the fiber laser wavelength changes continuously with temperature, tracking several temperature points observed the self-heterodyne spectrum and found that the changes in spectra of the 3dB bandwidth of less than 1kHz, and therefore the fiber laser with election-mode fiber Bragg grating shows excellent spectral properties and wavelength stability.

  17. Laser cladding technology to small diameter pipes

    International Nuclear Information System (INIS)

    Fujimagari, H.; Hagiwara, M.; Kojima, T.

    2000-01-01

    A laser cladding method which produces a highly corrosion-resistant material coating layers (cladding) on the austenitic stainless steel (type 304 SS) pipe inner surface was developed to prevent SCC (stress corrosion cracking) occurrence. This technology is applicable to a narrow and long distance area from operators, because of the good accessibility of the YAG (yttrium-aluminum-garnet) laser beam that can be transmitted through an optical fiber. In this method a mixed paste metallic powder and heating-resistive organic solvent are firstly placed on the inner surface of a small pipe, and then a YAG laser beam transmitted through an optical fiber irradiates to the pasted area. A mixed paste will be melted and form a cladding layer subsequently. A cladding layer shows as excellent corrosion resistance property. This laser cladding (LC) method had already applied to several domestic nuclear power plants and had obtained a good reputation. This report introduces the outline of laser cladding technology, the developed equipment for practical application in the field, and the circumstance in actual plant application. (orig.)

  18. Thirty-centimeter-diameter ion milling source

    International Nuclear Information System (INIS)

    Robinson, R.S.

    1978-01-01

    A 30 cm beam diameter ion source has been designed and fabricated for micromachining and sputtering applications. An argon ion current density of 1 mA/cm 2 at 500 eV ion energy was selected as a design operating condition. The completed ion source met the design criteria at this operating condition with a uniform and well-collimated beam having an average variation in current density of +- 5% over the center of 20 cm of the beam. This ion source has a multipole magnetic field that employs permanent magnets between permeable pole pieces. Langmuir probe surveys of the source plasma support the design concepts of a multipole field and a circumferential cathode to enhance plasma uniformity

  19. Abutment height influences the effect of platform switching on peri-implant marginal bone loss.

    Science.gov (United States)

    Galindo-Moreno, Pablo; León-Cano, Ana; Monje, Alberto; Ortega-Oller, Inmaculada; O'Valle, Francisco; Catena, Andrés

    2016-02-01

    The purpose was to radiographically analyze and compare the marginal bone loss (MBL) between implants with different mismatching distance and to study the influence of the prosthetic abutment height on the MBL in association with the related mismatching distances. This retrospective study included 108 patients in whom 228 implants were placed, 180 with diameter of 4.5 mm and 48 with diameter of 5 mm. All patients received OsseoSpeed™ implants with internal tapered conical connection (Denstply Implants). Different mismatching distances were obtained, given that all implants were loaded with the same uni-abutment type (Lilac; Denstply Implants). Data were gathered on age, gender, bone substratum, smoking habits, previous history of periodontitis, and prosthetic features. MBL was analyzed radiographically at 6 and 18 months post-loading. Mixed linear analysis of mesial and distal MBL values yielded significant effects of abutment, implant diameter, follow-up period, bone substratum, smoking, and abutment × time interaction. MBL was greater at 18 vs. 6 months, for short vs. long abutments, for grafted vs. pristine bone, for a heavier smoking habit, and for implants with a diameter of 5.0 vs. 4.5 mm. Greater mismatching does not minimize the MBL; abutment height, smoking habit, and bone substratum may play a role in the MBL over the short- and medium term. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. In Vitro Laser Treatment Platform Construction with Dental Implant Thread Surface on Bacterial Adhesion for Peri-Implantitis

    Directory of Open Access Journals (Sweden)

    Hsien-Nan Kuo

    2017-01-01

    Full Text Available This study constructs a standard in vitro laser treatment platform with dental implant thread surface on bacterial adhesion for peri-implantitis at different tooth positions. The standard clinical adult tooth jaw model was scanned to construct the digital model with 6 mm bone loss depth on behalf of serious peri-implantitis at the incisor, first premolar, and first molar. A cylindrical suite connected to the implant and each tooth root in the jaw model was designed as one experimental unit set to allow the suite to be replaced for individual bacterial adhesion. The digital peri-implantitis and suite models were exported to fulfill the physical model using ABS material in a 3D printer. A 3 mm diameter specimen implant on bacterial adhesion against Escherichia coli was performed for gram-negative bacteria. An Er:YAG laser, working with a chisel type glass tip, was moved from the buccal across the implant thread to the lingual for about 30 seconds per sample to verify the in vitro laser treatment platform. The result showed that the sterilization rate can reach 99.3% and the jaw model was not damaged after laser irradiation testing. This study concluded that using integrated image processing, reverse engineering, CAD system, and a 3D printer to construct a peri-implantitis model replacing the implant on bacterial adhesion and acceptable sterilization rate proved the feasibility of the proposed laser treatment platform.

  1. Cinnamon Oil and Chitosan Coating on Orthopaedic Implant Surface for Prevention of Staphylococcus Epidermidis Biofilm Formation

    OpenAIRE

    R Magetsari; P Dewo; BK Saputro; Z Lanodiyu

    2014-01-01

    S. Epidermidis is among the most frequently isolated microorganisms found in -infection related to implanted devices and the formation of biofilm will be more resistantcompared to the planktonic form. This study was carried out determine the effect of coating on stainless steel orthopaedic implants surfaces with cinnamon oil and chitosan as bioadhesive to prevent biofilms formation of S. Epidermidis.The rod shaped stainless steel 316 L orthopaedic implant with 5 mm diameters was coated 2 t...

  2. Clinical implementation of stereotaxic brain implant optimization

    International Nuclear Information System (INIS)

    Rosenow, U.F.; Wojcicka, J.B.

    1991-01-01

    This optimization method for stereotaxic brain implants is based on seed/strand configurations of the basic type developed for the National Cancer Institute (NCI) atlas of regular brain implants. Irregular target volume shapes are determined from delineation in a stack of contrast enhanced computed tomography scans. The neurosurgeon may then select up to ten directions, or entry points, of surgical approach of which the program finds the optimal one under the criterion of smallest target volume diameter. Target volume cross sections are then reconstructed in 5-mm-spaced planes perpendicular to the implantation direction defined by the entry point and the target volume center. This information is used to define a closed line in an implant cross section along which peripheral seed strands are positioned and which has now an irregular shape. Optimization points are defined opposite peripheral seeds on the target volume surface to which the treatment dose rate is prescribed. Three different optimization algorithms are available: linear least-squares programming, quadratic programming with constraints, and a simplex method. The optimization routine is implemented into a commercial treatment planning system. It generates coordinate and source strength information of the optimized seed configurations for further dose rate distribution calculation with the treatment planning system, and also the coordinate settings for the stereotaxic Brown-Roberts-Wells (BRW) implantation device

  3. Sugar maple height-diameter and age-diameter relationships in an uneven-aged northern hardwood stand

    Science.gov (United States)

    Laura S. Kenefic; R.D. Nyland

    1999-01-01

    Sugar maple (Acer saccharum Marsh.) height-diameter and age-diameter relationships are explored in a balanced uneven-aged northern hardwood stand in central New York. Results show that although both height and age vary considerably with diameter, these relationships can be described by statistically valid equations. The age-diameter relationship...

  4. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  5. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  6. Influence of core diameter and length of polymer optical fiber on Brillouin scattering properties

    Science.gov (United States)

    Mizuno, Yosuke; Ishigure, Takaaki; Nakamura, Kentaro

    2012-02-01

    Brillouin scattering in perfluorinated graded-index polymer optical fibers (PFGI-POFs) is potentially useful in developing high-accuracy distributed temperature sensors with reduced strain sensitivity. In this study, we investigate, both experimentally and theoretically, the influence of the fiber core diameter and length on the Brillouin gain spectra (BGS) in PFGI-POFs. First, we show that smaller core diameter drastically enhances the Stokes power using PFGI-POFs with 62.5-μm and 120-μm core diameters, and discuss the Brillouin threshold power. Then, we demonstrate that the PFGI-POF length has little influence on the BGS when the length is longer than 50 m. We also predict that, at 1.55-μm wavelength, it is difficult to reduce the Brillouin threshold power of PFGI-POFs below that of long silica single-mode fibers even if their core diameter is sufficiently reduced to satisfy the single-mode condition. Finally, making use of the enhanced Stokes signal, we confirm the Brillouin linewidth narrowing effect.

  7. Narrow Networks on the Individual Marketplace in 2017.

    Science.gov (United States)

    Polski, Daniel; Weiner, Janet; Zhang, Yuehan

    2017-09-01

    This Issue Brief describes the breadth of physician networks on the ACA marketplaces in 2017. We find that the overall rate of narrow networks is 21%, which is a decline since 2014 (31%) and 2016 (25%). Narrow networks are concentrated in plans sold on state-based marketplaces, at 42%, compared to 10% of plans on federally-facilitated marketplaces. Issuers that have traditionally offered Medicaid coverage have the highest prevalence of narrow network plans at 36%, with regional/local plans and provider-based plans close behind at 27% and 30%. We also find large differences in narrow networks by state and by plan type.

  8. Slug Flow Analysis in Vertical Large Diameter Pipes

    Science.gov (United States)

    Roullier, David

    The existence of slug flow in vertical co-current two-phase flow is studied experimentally and theoretically. The existence of slug flow in vertical direction implies the presence of Taylor bubbles separated by hydraulically sealed liquid slugs. Previous experimental studies such as Ombere-Ayari and Azzopardi (2007) showed the evidence of the non-existence of Taylor bubbles for extensive experimental conditions. Models developed to predict experimental behavior [Kocamustafaogullari et al. (1984), Jayanti and Hewitt. (1990) and Kjoolas et al. (2017)] suggest that Taylor bubbles may disappear at large diameters and high velocities. A 73-ft tall and 101.6-mm internal diameter test facility was used to conduct the experiments allowing holdup and pressure drop measurements at large L/D. Superficial liquid and gas velocities varied from 0.05-m/s to 0.2 m/s and 0.07 m/s to 7.5 m/s, respectively. Test section pressure varied from 38 psia to 84 psia. Gas compressibility effect was greatly reduced at 84 psia. The experimental program allowed to observe the flow patterns for flowing conditions near critical conditions predicted by previous models (air-water, 1016 mm ID, low mixture velocities). Flow patterns were observed in detail using wire-mesh sensor measurements. Slug-flow was observed for a narrow range of experimental conditions at low velocities. Churn-slug and churn-annular flows were observed for most of the experimental data-points. Cap-bubble flow was observed instead of bubbly flow at low vSg. Wire-mesh measurements showed that the liquid has a tendency to remain near to the walls. The standard deviation of radial holdup profile correlates to the flow pattern observed. For churn-slug flow, the profile is convex with a single maximum near the pipe center while it exhibits a concave shape with two symmetric maxima close to the wall for churn-annular flow. The translational velocity was measured by two consecutive wire-mesh sensor crosscorrelation. The results show

  9. Vortex formation in narrow ferromagnetic rings

    International Nuclear Information System (INIS)

    Klaeui, M; Vaz, C A F; Lopez-Diaz, L; Bland, J A C

    2003-01-01

    The high-symmetry ring geometry is shown to exhibit a wide range of intriguing magnetostatic and magnetodynamic properties, which we survey in this topical review. We consider first the patterning and deposition techniques, which are used to fabricate ring structures (diameters between 0.1 and 2 μm) and discuss their respective advantages and disadvantages. The results of direct nanoscale imaging of the novel magnetization configurations present in rings with different geometrical parameters (including discs) are discussed. These results give valuable insight into the influence of the magnetic anisotropies governing the magnetic states. The different types of domain walls that arise are compared quantitatively to micromagnetic simulations. The magnetodynamic switching between the different magnetic states is described in detail. In particular we elaborate on the different geometry-dependent magnetic switchings, since the different transitions occurring allow us to determine which energy terms govern the reversal process. We discuss a process by which fast (sub-ns) and controlled switching can be achieved, therefore making rings an attractive geometry for applications, in addition to studying fundamental issues of nanomagnetism. (topical review)

  10. Waste system optimization - can diameter selection

    International Nuclear Information System (INIS)

    Ashline, R.C.

    1983-08-01

    The purpose of the waste system optimization study is to define in terms of cost incentives the preferred waste package for HLW which has been converted to glass at a commercial reprocessing plant. The Waste Management Economic Model (WMEM) was employed to analyze the effect of varying important design parameters on the overall net present cost of waste handling. The parameters found to have the greatest effect on the calculated overall net present cost were can diameter, repository type (salt, basalt/bentonite, or welded tuff), allowable areal heat loading, and the repository availability date. The overall net present of a waste handling option is calculated over a 20-year operating period. It includes the total capital and operating costs associated with high-level and intermediate-level liquid waste storage, liquid waste solidification, hulls storage and compaction, and general process trash handling. It also includes the cask leasing and transportation costs associated with each waste type and the waste repository disposal costs. The waste repository disposal costs used in WMEM for this analysis were obtained from Battelle Pacific Northwest Laboratories and thir RECON model. 2 figures, 2 tables

  11. Packing configuration performance for small stem diameters

    International Nuclear Information System (INIS)

    Aikin, J.A.; Spence, C.G.; Cumming, D.

    1997-01-01

    The extensive use of graphite packing and its excellent track record for large isolating valves in CANDU, Primary Heat Transfer (PHT) systems has resulted in an increased application of graphite packing on the conventional side. Many of these applications are in air operated valves (AOVs) where the packing sets are used on small stem diameters (<1 inch) with frequent short-cycling strokes (± 10% of full stroke). The direct application of the proven packing configurations for large isolated valves to control valve application has generated problems such as stiction, packing wear and, in isolated cases, stem stall. To address this issue, a test program was conducted at AECL, CRL by MED branch. The testing showed that by reconfiguring the packing sets and using PTFE wafers reductions in stem friction of 50% at ambient conditions, a 3 fold at hot conditions are achievable. The test program also demonstrated benefits gained in packing wear with different stem roughness finishes and the potential need to exercise small stems valves that see less than full stroke cycling. The paper describes the tests results and provides field support experience. (author)

  12. [Total cervical disk replacement--implant-specific approaches: keel implant (Prodisc-C intervertebral disk prosthesis)].

    Science.gov (United States)

    Korge, Andreas; Siepe, Christoph J; Heider, Franziska; Mayer, H Michael

    2010-11-01

    Dynamic intervertebral support of the cervical spine via an anterolateral approach using a modular artificial disk prosthesis with end-plate fixation by central keel fixation. Cervical median or mediolateral disk herniations, symptomatic cervical disk disease (SCDD) with anterior osseous, ligamentous and/or discogenic narrowing of the spinal canal. Cervical fractures, tumors, osteoporosis, arthrogenic neck pain, severe facet degeneration, increased segmental instability, ossification of posterior longitudinal ligament (OPLL), severe osteopenia, acute and chronic systemic, spinal or local infections, systemic and metabolic diseases, known implant allergy, pregnancy, severe adiposity (body mass index > 36 kg/m2), reduced patient compliance, alcohol abuse, drug abuse and dependency. Exposure of the anterior cervical spine using the minimally invasive anterolateral approach. Intervertebral fixation of retainer screws. Intervertebral diskectomy. Segmental distraction with vertebral body retainer and vertebral distractor. Removal of end-plate cartilage. Microscopically assisted decompression of spinal canal. Insertion of trial implant to determine appropriate implant size, height and position. After biplanar image intensifier control, drilling for keel preparation using drill guide and drill bit, keel-cut cleaner to remove bone material from the keel cut, radiologic control of depth of the keel cut using the corresponding position gauge. Implantation of original implant under lateral image intensifier control. Removal of implant inserter. Functional postoperative care and mobilization without external support, brace not used routinely, soft brace possible for 14 days due to postoperative pain syndromes. Implantation of 100 cervical Prodisc-C disk prostheses in 78 patients (average age 48 years) at a single center. Clinical and radiologic follow-up 24 months postoperatively. Significant improvement based on visual analog scale and Neck Disability Index. Radiologic

  13. The Effects of Bougie Diameters on Tissue Oxygen Levels After Sleeve Gastrectomy: A Randomized Experimental Trial

    Directory of Open Access Journals (Sweden)

    Can Konca

    2018-05-01

    Full Text Available Background: Staple-line leak is the most frightening complication of laparoscopic sleeve gastrectomy and several predisposing factors such as using improper staple sizes regardless of gastric wall thickness, narrower bougie diameter and ischemia of the staple line are asserted. Aims: To evaluate the effects of different bougie diameters on tissue oxygen partial pressure at the esophagogastric junction after sleeve gastrectomy. Study Design: A randomized and controlled animal experiment with 1:1:1:1 allocation ratio. Methods: Thirty-two male Wistar Albino rats were randomly divided into 4 groups of 8 each. While 12-Fr bougies were used in groups 1 and 3, 8-Fr bougies were used in groups 2 and 4. Fibrin sealant application was also carried out around the gastrectomy line after sleeve gastrectomy in groups 3 and 4. Burst pressure of gastrectomy line, tissue oxygen partial pressure and hydroxyproline levels at the esophagogastric junction were measured and compared among groups. Results: Mortality was detected in 2 out of 32 rats (6.25% and one of them was in group 2 and the cause of this mortality was gastric leak. Gastric leak was detected in 2 out of 32 rats (6.25%. There was no significant difference in terms of burst pressures, tissue oxygen partial pressure and tissue hydroxyproline levels among the 4 groups. Conclusion: The use of narrower bougie along with fibrin sealant has not had a negative effect on tissue perfusion and wound healing.

  14. Submerged arc narrow gap welding of the steel DIN 20MnMoNi55

    International Nuclear Information System (INIS)

    Moraes, M.M.

    1987-01-01

    The methodology for submerged arc narrow gap welding for high thickness rolled steel DIN 20MnMoNi55 was developed, using din S3NiMo1 04 mm and 05 mm wires, and DIN 8B435 flux. For this purpose, submerged arc narrow gap welded joints with 50 mm and 120 mm thickness were made aiming the welding parameters optimization and the study of the influence of welding voltage, wire diameter and wire to groove face distance on the operational performance and on the welded joint quality, specially on the ISO-V impact toughness. These welded joints were checked by non-destructive mechanical and metallographic tests. Results were compared with those obtained by one 120 mm thickness submerged arc conventional gap welded joint, using the same base metal and consumables (05 mm wire). The analysis of the results shows that the increasing of the wire to groove face distance and the welding voltage increases the hardness and the ISO-V impact toughness of the weld metal. It shows that the reduction of the gap angle is the main cause for the obtained of a heat affected zone free from coarse grains, the reduction of the welding voltage, the increasing of the wire to groove face distance, and the grounding optimization also contribute for that. It was also concluded that the quality and the execution complexity level of a narrow gap welded joint are identical to a conventional gap welded joint. (author) [pt

  15. PARAMETERS OF NUCLEAR MAGNETIC RESONANCE IN PATIENTS WITH CONGENITAL NARROWING OF THE LUMBAR SPINAL CANAL

    Directory of Open Access Journals (Sweden)

    ELIU HAZAEL MORALES-RANGEL

    Full Text Available ABSTRACT Objective: To compare the morphological parameters of magnetic resonance in patients with congenital narrowing of the lumbar spinal canal with patients with low back pain. Methods: A descriptive, retrospective, observational study was conducted with measurements in the axial and sagittal magnetic resonance sections of the vertebral body and canal of the lumbar spine of 64 patients with diagnosis of low back pain, which were compared with resonance images taken from 31 Mexican patients with congenital narrowing of the lumbar spinal canal. Results: The results show that patients with congenital narrowing of the lumbar spinal canal in the axial sections have a difference in diameters, being L2<13.9 mm, L3<13.3 mm, L4<12.9 mm, L5<13.1 mm, compared with controls L2<20.5 mm, L3<20.5 mm, L4<19.3 mm, L5<18.1 mm with p = 0.000. Conclusions: We found different measurements in the Mexican population compared to those found by similar studies. With the parameters obtained, it would be possible to make the proper diagnosis, surgical planning, and treatment.

  16. Mg2BIV: Narrow Bandgap Thermoelectric Semiconductors

    Science.gov (United States)

    Kim, Il-Ho

    2018-05-01

    Thermoelectric materials can convert thermal energy directly into electric energy and vice versa. The electricity generation from waste heat via thermoelectric devices can be considered as a new energy source. For instance, automotive exhaust gas and all industrial processes generate an enormous amount of waste heat that can be converted to electricity by using thermoelectric devices. Magnesium compound Mg2BIV (BIV = Si, Ge or Sn) has a favorable combination of physical and chemical properties and can be a good base for the development of new efficient thermoelectrics. Because they possess similar properties to those of group BIV elemental semiconductors, they have been recognized as good candidates for thermoelectric applications. Mg2Si, Mg2Ge and Mg2Sn with an antifluorite structure are narrow bandgap semiconductors with indirect band gaps of 0.77 eV, 0.74 eV, and 0.35 eV, respectively. Mg2BIV has been recognized as a promising material for thermoelectric energy conversion at temperatures ranging from 500 K to 800 K. Compared to other thermoelectric materials operating in the similar temperature range, such as PbTe and filled skutterudites, the important aspects of Mg2BIV are non-toxic and earth-abundant elements. Based on classical thermoelectric theory, the material factor β ( m* / m e)3/2μκ L -1 can be utilized as the criterion for thermoelectric material selection, where m* is the density-of-states effective mass, me is the mass of an electron, μ is the carrier mobility, and κL is the lattice thermal conductivity. The β for magnesium silicides is 14, which is very high compared to 0.8 for iron silicides, 1.4 for manganese silicides, and 2.6 for silicon-germanium alloys. In this paper, basic phenomena of thermoelectricity and transport parameters for thermoelectric materials were briefly introduced, and thermoelectric properties of Mg2BIV synthesized by using a solid-state reaction were reviewed. In addition, various Mg2BIV compounds were discussed

  17. Trapping of deuterium in krypton-implanted nickel

    International Nuclear Information System (INIS)

    Frank, R.C.; McManus, S.P.; Rehn, L.E.; Baldo, P.

    1986-01-01

    Krypton ions with energy 600 keV were implanted in nickel to fluences of 2 x 10 16 cm -2 under three different conditions. Deuterium was subsequently introduced into the implanted regions by electrolysis at room temperature. After the diffusible deuterium was permitted to escape, the 2 H( 3 He, 1 H) 4 He nuclear reaction was used to analyze for the trapped deuterium during an isochronal annealing program. The region implanted at 100 0 C with no higher temperature anneal had the largest number of traps; the region implanted at 100 0 C and annealed for 100 min at 500 0 C had considerably less; the region implanted at 500 0 C had the least. Electron diffraction patterns confirmed the existence of solid crystalline krypton in all three regions. Transmission electron microscope studies revealed precipitates with an average diameter of 8 nm in the region implanted at 500 0 C. The two regions implanted at 100 0 C contained smaller precipitates. Trap binding enthalpies were obtained by math modeling. In addition to the traps with binding enthalpy of 0.55 eV reported earlier by other investigators for helium implanted in nickel, a smaller number of traps with binding enthalpies up to 0.83 eV were also found. The trapping of deuterium by various types of imperfections, including the solid krypton precipitates, is discussed

  18. Q2 anti Q2 states with relatively narrow widths

    International Nuclear Information System (INIS)

    Ono, Seiji.

    1978-09-01

    Using the mass formulas which correctly predict the mass of mesons and baryons the mass of diquark states is computed. From this mass spectrum the existance of the observed narrow baryonia and wide baryonia can be naturally understood. Other relatively narrow Q 2 anti Q 2 states are predicted to exist. (orig.) [de

  19. Bayesian Face Recognition and Perceptual Narrowing in Face-Space

    Science.gov (United States)

    Balas, Benjamin

    2012-01-01

    During the first year of life, infants' face recognition abilities are subject to "perceptual narrowing", the end result of which is that observers lose the ability to distinguish previously discriminable faces (e.g. other-race faces) from one another. Perceptual narrowing has been reported for faces of different species and different races, in…

  20. Optical effects of ion implantation

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1987-01-01

    The review concerns the effects of ion implantation that specifically relate to the optical properties of insulators. Topics which are reviewed include: ion implantation, ion range and damage distributions, colour centre production by ion implantation, high dose ion implantation, and applications for integrated optics. Numerous examples are presented of both diagnostic and industrial examples of ion implantation effects in insulators. (U.K.)

  1. Demineralized water flow cancelling experiments with ice plug into high diameter horizontal tube (300 nominal diameter)

    International Nuclear Information System (INIS)

    Gyongyosi, T.; Valeca, S.; Corbescu, B.; Puiu, D.; Panaitescu, V. N.

    2015-01-01

    The isolation with ice plug of a high diameter horizontal pipeline section is a specific technique for repairs activities/ replacements of components owning to thermo-hydraulic installations working with liquid agents. The application of such technique don.t assumes stopping of the entire system. The ice plugging inside of the pipeline assumes using of a special device and of an own specific technology for application. The paper contains a brief description of the experimental technological facilities used, followed by setting off the main moments in evolution of two experimental tests carried out on the test section with 300 mm nominal diameter for demineralized water and, finally, by a brief results analysis and some conclusions. The paper is dedicated to the specialists working in the research and technological engineering. (authors)

  2. Modelling diameter growth, mortality and recruitment of trees in ...

    African Journals Online (AJOL)

    Modelling diameter growth, mortality and recruitment of trees in miombo woodlands of Tanzania. ... Individual tree diameter growth and mortality models, and area-based recruitment models were developed. ... AJOL African Journals Online.

  3. Nineteen-Foot Diameter Explosively Driven Blast Simulator; TOPICAL

    International Nuclear Information System (INIS)

    VIGIL, MANUEL G.

    2001-01-01

    This report describes the 19-foot diameter blast tunnel at Sandia National Laboratories. The blast tunnel configuration consists of a 6 foot diameter by 200 foot long shock tube, a 6 foot diameter to 19 foot diameter conical expansion section that is 40 feet long, and a 19 foot diameter test section that is 65 feet long. Therefore, the total blast tunnel length is 305 feet. The development of this 19-foot diameter blast tunnel is presented. The small scale research test results using 4 inch by 8 inch diameter and 2 foot by 6 foot diameter shock tube facilities are included. Analytically predicted parameters are compared to experimentally measured blast tunnel parameters in this report. The blast tunnel parameters include distance, time, static, overpressure, stagnation pressure, dynamic pressure, reflected pressure, shock Mach number, flow Mach number, shock velocity, flow velocity, impulse, flow duration, etc. Shadowgraphs of the shock wave are included for the three different size blast tunnels

  4. Shiitake mushroom production on small diameter oak logs in Ohio

    Science.gov (United States)

    S.M. Bratkovich

    1991-01-01

    Yields of different strains of shiitake mushrooms (Lentinus edodes) were evaluated when produced on small diameter oak logs in Ohio. Logs averaging between 3-4 inches in diameter were inoculated with four spawn strains in 1985.

  5. Instability of Reference Diameter in the Evaluation of Stenosis After Coronary Angioplasty: Percent Diameter Stenosis Overestimates Dilative Effects Due to Reference Diameter Reduction

    International Nuclear Information System (INIS)

    Hirami, Ryouichi; Iwasaki, Kohichiro; Kusachi, Shozo; Murakami, Takashi; Hina, Kazuyoshi; Matano, Shigeru; Murakami, Masaaki; Kita, Toshimasa; Sakakibara, Noburu; Tsuji, Takao

    2000-01-01

    Purpose: To examine changes in the reference segment luminal diameter after coronary angioplasty.Methods: Sixty-one patients with stable angina pectoris or old myocardial infarction were examined. Coronary angiograms were recorded before coronary angioplasty (pre-angioplasty) and immediately after (post-angioplasty), as well as 3 months after. Artery diameters were measured on cine-film using quantitative coronary angiographic analysis.Results: The diameters of the proximal segment not involved in the balloon inflation and segments in the other artery did not change significantly after angioplasty, but the reference segment diameter significantly decreased (4.7%). More than 10% luminal reduction was observed in seven patients (11%) and more than 5% reduction was observed in 25 patients (41%). More than 5% underestimation of the stenosis was observed in 22 patients (36%) when the post-angioplasty reference diameter was used as the reference diameter, compared with when the pre-angioplasty measurement was used and more than 10% underestimation was observed in five patients (8%).Conclusion: This study indicated that evaluation by percent diameter stenosis, with the reference diameter from immediately after angioplasty, overestimates the dilative effects of coronary angioplasty, and that it is thus better to evaluate the efficacy of angioplasty using the absolute diameter in addition to percent luminal stenosis

  6. Abnormal splenic artery diameter/hepatic artery diameter ratio in cirrhosis-induced portal hypertension

    Science.gov (United States)

    Zeng, Dao-Bing; Dai, Chuan-Zhou; Lu, Shi-Chun; He, Ning; Wang, Wei; Li, Hong-Jun

    2013-01-01

    AIM: To determine an optimal cutoff value for abnormal splenic artery diameter/proper hepatic artery diameter (S/P) ratio in cirrhosis-induced portal hypertension. METHODS: Patients with cirrhosis and portal hypertension (n = 770) and healthy volunteers (n = 31) underwent volumetric computed tomography three-dimensional vascular reconstruction to measure the internal diameters of the splenic artery and proper hepatic artery to calculate the S/P ratio. The cutoff value for abnormal S/P ratio was determined using receiver operating characteristic curve analysis, and the prevalence of abnormal S/P ratio and associations between abnormal S/P ratio and major complications of portal hypertension were studied using logistic regression. RESULTS: The receiver operating characteristic analysis showed that the cutoff points for abnormal splenic artery internal diameter and S/P ratio were > 5.19 mm and > 1.40, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.2%, 45.2%, 97.1%, and 6.6%, respectively. The prevalence of an abnormal S/P ratio in the patients with cirrhosis and portal hypertension was 83.4%. Patients with a higher S/P ratio had a lower risk of developing ascites [odds ratio (OR) = 0.708, 95%CI: 0.508-0.986, P = 0.041] and a higher risk of developing esophageal and gastric varices (OR = 1.483, 95%CI: 1.010-2.175, P = 0.044) and forming collateral circulation (OR = 1.518, 95%CI: 1.033-2.230, P = 0.034). After splenectomy, the portal venous pressure and maximum and mean portal venous flow velocities were reduced, while the flow rate and maximum and minimum flow velocities of the hepatic artery were increased (P portal hypertension, and it can be used as an important marker of splanchnic hemodynamic disturbances. PMID:23483462

  7. Ion implantation in semiconductors

    International Nuclear Information System (INIS)

    Gusev, V.; Gusevova, M.

    1980-01-01

    The historical development is described of the method of ion implantation, the physical research of the method, its technological solution and practical uses. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material, ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions. (M.S.)

  8. Ion implantation in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, V; Gusevova, M

    1980-06-01

    The historical development of the method of ion implantation, the physical research of the method, its technological solution and practical uses is described. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material and ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions.

  9. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  10. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  11. High energy ion implantation

    International Nuclear Information System (INIS)

    Ziegler, J.F.

    1985-01-01

    High energy ion implantation offers the oppertunity for unique structures in semiconductor processing. The unusual physical properties of such implantations are discussed as well as the special problems in masking and damage annealing. A review is made of proposed circuit structures which involve deep implantation. Examples are: deep buried bipolar collectors fabricated without epitaxy, barrier layers to reduce FET memory sensitivity to soft-fails, CMOS isolation well structures, MeV implantation for customization and correction of completed circuits, and graded reach-throughs to deep active device components. (orig.)

  12. [Silastic implant and synovitis].

    Science.gov (United States)

    Sennwald, G

    1989-07-22

    The silastic implant based on siloxane polymere induces granulomatous synovitis in certain predisposed individuals, a reaction which may continue even after removal of the implant. This is also true of a prosthesis of the trapezium in two of our patients, though to a lesser degree. This is probably the reason why the problem has not yet been widely recognized. The hypothesis is put forward that an enzymatic predisposition may allow chemical degradation of the fragmented silastic implant into a toxic component responsible for the pathologic condition. The slow progression of the lesions is a challenge for the future and puts in question the further use of silastic implants.

  13. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  14. MAG narrow gap welding - an economic way to minimize welding expenses

    International Nuclear Information System (INIS)

    Kast, W.; Scholz, E.; Weyland, F.

    1982-01-01

    The thicker structural components are, the more important it is to take measures to reduce the volume of the weld. The welding process requiring the smallest possible weld section is the so-called narrow gap process. In submerged arc narrow gap welding as well as in MAG narrow gap welding different variants are imaginable, some of them already in practical use. With regard to efficiency and weld quality an optimum variant of the MAG narrow gap welding process is described. It constitutes a two wire system in which two wire electrodes of 1.2 mm diameter are arranged one behind the other. In order to avoid lack of fusion, the wire guides are slightly pointed towards each groove face. Thus, by inclining the two arcs burning one behind the other in the direction of weld progress, it is achieved that two separately solidifying weld pools and two beads per layer are simultaneously formed. Welding parameters are selected in such a way that a heat input of 16-20 kJ/cm and a deposition rate of 11-16 kgs/h are obtained. In spite of this comparatively high deposition rate, good impact values are found both in the weld and HAZ (largely reduced coarse-grain zone) which is due to an optimum weld build-up. With the available welding equipment the process can be applied to structural members having a thickness of 40-400 mm. The width of gap is 13 mm (root section) with a bevel angle of 1 0 . As filler metal, basic flux-cored wires are used which, depending on the base metal to be welded and the required tensile properties, can be of the Mn-, MnMo-, MnCrMo-, MnNi-, or MnNiMo-alloyed types. (orig.)

  15. Imaging of 1.0-mm-diameter radiopaque markers with megavoltage X-rays: an improved online imaging system

    International Nuclear Information System (INIS)

    Pang, G.; Beachey, D.J.; O'Brien, P.F.; Rowlands, J.A.

    2002-01-01

    Purpose: To improve an online portal imaging system such that implanted cylindrical gold markers of small diameter (no more than 1.0 mm) can be visualized. These small markers would make the implantation procedure much less traumatic for the patient than the large markers (1.6 mm in diameter), which are usually used today to monitor prostate interfraction motion during radiation therapy. Methods and Materials: Several changes have been made to a mirror-video based online imaging system to improve image quality. First, the conventional camera tube was replaced by an avalanche-multiplication-based video tube. This new camera tube has very high gain at the target such that the camera noise, which is one of the main causes of image degradation of online portal imaging systems, was overcome and effectively eliminated. Second, the conventional linear-accelerator (linac) target was replaced with a low atomic number (low-Z) target such that more diagnostic X-rays are present in the megavoltage X-ray beam. Third, the copper plate buildup layer for the phosphor screen was replaced by a thin plastic layer for detection of the diagnostic X-ray components in the beam generated by the low-Z target. Results: Radiopaque fiducial gold markers of different sizes, i.e., 1.0 mm (diameter) x 5 mm (length) and 0.8 mm (diameter) x 3 mm (length), embedded in an Alderson Rando phantom, can be clearly seen on the images acquired with our improved system. These markers could not be seen on images obtained with any commercial system available in our clinic. Conclusion: This work demonstrates the visibility of small-diameter radiopaque markers with an improved online portal imaging system. These markers can be easily implanted into the prostate and used to monitor the interfraction motion of the prostate

  16. Association of lens vault with narrow angles among different ethnic groups.

    Science.gov (United States)

    Lee, Roland Y; Huang, Guofu; Cui, Qi N; He, Mingguang; Porco, Travis C; Lin, Shan C

    2012-06-01

    To compare lens vault between open-angle and narrow-angle eyes in African-, Caucasian-, Hispanic-, Chinese- and Filipino-Americans. In this prospective study, 436 patients with open angle and narrow angle based on the Shaffer gonioscopic grading classification underwent anterior-segment optical coherence tomography. The Zhongshan Angle Assessment Program was used to calculate lens vault. The narrow-angle group included 32 Chinese-Americans, 22 Filipino-Americans, 26 African-Americans, 24 Hispanic-Americans and 73 Caucasian-Americans. The open-angle group included 56 Chinese-Americans, 29 Filipino-Americans, 45 African-Americans, 27 Hispanic-Americans and 102 Caucasian-Americans. Linear mixed effect regression models, accounting for the use of both eyes and adjusting for age, sex, pupil diameter and spherical equivalent, were used to test for the ethnicity and angle coefficients. Tukey's multiple comparison test was used for pairwise comparisons among the open-angle racial groups. Significant difference in lens vault was found among the open-angle racial groups (P = 0.022). For the open-angle patients, mean values for the lens vault measurements were 265 ± 288 µm for Chinese-Americans, 431 ± 248 µm for Caucasian-Americans, 302 ± 213 µm for Filipino-Americans, 304 ± 263 µm for Hispanic-Americans and 200 ± 237 µm for African-Americans. Using Tukey's multiple comparison for pairwise comparisons among the open-angle racial groups, a significant difference was found between African-American and Caucasian-Americans groups (P values for the rest of the pairwise comparisons were not statistically significant. No significant difference was found among the narrow-angle racial groups (P = 0.14). Comparison between the open angle and narrow angle within each racial group revealed significant difference for all racial groups (P < 0.05). Among all the ethnicities included in this study, narrow-angle eyes have greater lens vault compared to open

  17. Short Dental Implants Retaining Two-Implant Mandibular Overdentures in Very Old, Dependent Patients: Radiologic and Clinical Observation Up to 5 Years.

    Science.gov (United States)

    Maniewicz, Sabrina; Buser, Ramona; Duvernay, Elena; Vazquez, Lydia; Loup, Angelica; Perneger, Thomas V; Schimmel, Martin; Müller, Frauke

    To describe the survival rate and peri-implant bone loss in very old patients dependent for their activities of daily living (ADL), treated with mandibular two-implant overdentures (IODs) in the context of a previously reported randomized controlled trial. A total of 19 patients received two interforaminal Straumann implants (Regular Neck, 4.1 mm diameter, 8 mm length) that were subsequently loaded with Locator attachments, transforming their preexisting inferior conventional denture into an IOD. The primary outcome measures were implant survival rate and radiographically assessed peri-implant bone loss. Secondary outcome measures included peri-implant probing depth and Plaque Index scores, as well as implant mobility. Nutritional state (body mass index and blood markers) and cognitive state (Mini-Mental State Examination) were also analyzed. The patient cohort comprised eight men and 11 women with a mean age of 85.7 ± 6.6 years. The implant survival rate up to 5 years was 94.7%, with one early and one late implant failure. The mean loss of peri-implant bone height was 0.17 mm per year (95% confidence interval: 0.09 to 0.24; P implant probing depth and Plaque Index scores were low and stable during the first 2 years, and thereafter increased continuously. Correlation analysis suggests that a reduced cognitive function and nutritional state are not a particular risk factor for accelerated peri-implant bone loss. The high implant survival and acceptable peri-implant health suggest that neither age nor dependency for the ADLs is a contraindication for the placement of implants. Nevertheless, close monitoring of the patients concerning a potential further functional decline precluding denture management and performing oral hygiene measures is advised.

  18. Evaluation of single-tooth implants in the second molar region: a 5-year life-table analysis of a retrospective study.

    Science.gov (United States)

    Koo, Ki-Tae; Wikesjö, Ulf M E; Park, Jang-Yeol; Kim, Tae-Il; Seol, Yang-Jo; Ku, Young; Rhyu, In-Chul; Chung, Chong-Pyoung; Lee, Yong-Moo

    2010-09-01

    To our knowledge, no study has evaluated the success or survival rate of single-tooth implants that replaced missing maxillary and mandibular second molars. The purpose of the present study was to evaluate the 1- to 5-year cumulative survival rate (CSR) for single-tooth implants placed in the second molar region and the effects of associated factors. Four hundred eighty-nine patients (298 males and 191 females; age range: 23 to 91 years; mean age: 47 years) who were admitted to the Seoul National University Dental Hospital between March 2003 and July 2008 and treated with single-tooth implants in the second molar region (227 maxillary implants and 294 mandibular implants; total: 521 implants) were included in the study. Thirty-two subjects received two implants each. A 1- to 5-year CSR was calculated using a life-table analysis. A comparison of CSRs between maxillary versus mandibular implants, one-stage versus two-stage implants, short (10 mm) implants, and standard-diameter (or=5.0 mm) implants was performed using Wilcoxon (Gehan) statistics. P CSR was 95.1%. There were no statistically significant differences in CSRs between implants placed in maxillas and mandibles (96.3% versus 94.9%, respectively; P = 0.084), one- and two-stage implants (95.6% versus 94.7%, respectively; P = 0.267), short and long implants (100% versus 95.1%, respectively; P = 0.582), and standard- and wide-diameter implants (93.8% versus 96.8%, respectively; P = 0.065). Within the limitations of the study, the placement of single-tooth implants in the second molar region was an effective and reliable treatment modality. Also, associated factors such as implant diameter, length, and location (the maxilla versus the mandible) may not have an impact on the long-term success of implants.

  19. Numerical simulation of two-phase slug flow with liquid carryover in different diameter ratio T-junction

    Science.gov (United States)

    Pao, W.; Hon, L.; Saieed, A.; Ban, S.

    2017-10-01

    A smaller diameter conduit pointing at 12 o’clock position is typically hot-tapped to a horizontal laying production header in offshore platform to tap produced gas for downstream process train. This geometric feature is commonly known as T-junction. The nature of multiphase fluid splitting at the T-junction is a major operational challenge due to unpredictable production environment. Often, excessive liquid carryover occurs in the T-junction, leading to complete platform trip and halt production. This is because the downstream process train is not designed to handle excessive liquid. The objective of this research is to quantify the effect of different diameter ratio on phase separation efficiency in T-junction. The liquid carryover is modelled as two-phase air-water flow using Eulerian Mixture Model coupled with Volume of Fluid Method to mimic the slug flow in the main pipe. The focus in this paper is 0.0254 m (1 inch) diameter horizontal main arm and vertical branch arm with diameter ratio of 1.0, 0.5 and 0.3. The present research narrowed the investigation to only slug flow regime using Baker’s map as reference. The investigation found that, contrary to common believe, smaller diameter ratio T-junction perform worse than larger diameter ratio T-junction.

  20. Unzipping of multi-wall carbon nanotubes with different diameter distributions: Effect on few-layer graphene oxide obtention

    Science.gov (United States)

    Torres, D.; Pinilla, J. L.; Suelves, I.

    2017-12-01

    Few-layer graphene oxide (FLGO) was obtained by chemical unzipping of multi-wall carbon nanotubes (MWCNT) of different diameter distributions. MWCNT were synthesized by catalytic decomposition of methane using Fe-Mo/MgO catalysts. The variation in the Fe/Mo ratio (1, 2 and 5) was very influential in MWCNT diameter distribution and type of MWCNT obtained, including textural, chemical, structural and morphological characteristics. MWCNT diameter distribution and surface defects content had a profound impact on the characteristics of the resulting FLGO. Thus, MWCNT obtained with the catalyst with a Fe/Mo: 5 and presenting a narrow diameter distribution centered at 8.6 ± 3.3 nm led to FLGO maintaining non-oxidized graphite stacking (according to XRD analysis), lower specific surface area and higher thermostability as compared to FLGO obtained from MWCNT showing wider diameter distributions. The presence of more oxygen-containing functionalities and structural defects in large diameter nanotubes promotes the intercalation of species towards the inner layers of the nanotube, resulting in an enhanced MWCNT oxidation and opening into FLGO, what improves both micro- and mesoporosity.

  1. Displacer Diameter Effect in Displacer Pulse Tube Refrigerator

    Science.gov (United States)

    Zhu, Shaowei

    2017-12-01

    Gas driving displacer pulse tube refrigerators are one of the work recovery type of pulse tube refrigerators whose theoretical efficiency is the same as Stirling refrigerators'. Its cooling power is from the displacement of the displacer. Displace diameter, rod diameter and pressure drop of the regenerator influence the displacement, which are investigated by numerical simulation. It is shown that the displacement ratio of the displacer over the piston is almost not affected by the displacer diameter at the same rod diameter ratio, or displacer with different diameters almost has the same performance.

  2. Silver nanoparticle formation in thin oxide layer on silicon by silver-negative-ion implantation for Coulomb blockade at room temperature

    International Nuclear Information System (INIS)

    Tsuji, Hiroshi; Arai, Nobutoshi; Matsumoto, Takuya; Ueno, Kazuya; Gotoh, Yasuhito; Adachi, Kouichiro; Kotaki, Hiroshi; Ishikawa, Junzo

    2004-01-01

    Formation of silver nanoparticles formed by silver negative-ion implantation in a thin SiO 2 layer and its I-V characteristics were investigated for development single electron devices. In order to obtain effective Coulomb blockade phenomenon at room temperature, the isolated metal nanoparticles should be in very small size and be formed in a thin insulator layer such as gate oxide on the silicon substrate. Therefore, conditions of a fine particles size, high particle density and narrow distribution should be controlled at their formation without any electrical breakdown of the thin insulator layer. We have used a negative-ion implantation technique with an advantage of 'charge-up free' for insulators, with which no breakdown of thin oxide layer on Si was obtained. In the I-V characteristics with Au electrode, the current steps were observed with a voltage interval of about 0.12 V. From the step voltage the corresponded capacitance was calculated to be 0.7 aF. In one nanoparticle system, this value of capacitance could be given by a nanoparticle of about 3 nm in diameter. This consideration is consistent to the measured particle size in the cross-sectional TEM observation. Therefore, the observed I-V characteristics with steps are considered to be Coulomb staircase by the Ag nanoparticles

  3. Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants

    OpenAIRE

    Estelita, Sérgio; Janson, Guilherme; Chiqueto, Kelly; Ferreira, Eduardo Silveira

    2014-01-01

    Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 follo...

  4. Advanced intimal hyperplasia without luminal narrowing of leptomeningeal arteries in CADASIL.

    Science.gov (United States)

    Dong, Hairong; Ding, Haixia; Young, Kelly; Blaivas, Mila; Christensen, Paul J; Wang, Michael M

    2013-05-01

    Leptomeningeal artery abnormalities in Cerebral Autosomal-Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy (CADASIL) have not been extensively characterized. We quantified substructure and diameter of leptomeningeal arteries in CADASIL compared with age-matched controls and the very old; in addition, we characterized intimal thickening in CADASIL using immunohistochemistry. Frontal and temporal cortex of 6 genetically proven CADASIL brains (average age, 66 years), 6 controls without symptoms of cerebrovascular disease, and 6 very old brains (average age, 89 years) were examined for leptomeningeal artery intimal, medial, and adventitial thickness; inner diameter; and sclerotic index and for smooth muscle markers. The intima of CADASIL arteries was thickened 5-fold compared with controls and the very aged (PMedial thickness was lower in CADASIL compared with controls and the very old (PArterial diameters were not smaller in CADASIL compared with controls. Sclerotic index was significantly increased in CADASIL compared with other groups (Parteries in CADASIL include intimal thickening and medial thinning, but not luminal narrowing. Smooth muscle-like cells participate in neointimal thickening of CADASIL arteries.

  5. Percutaneous and skeletal biocarbon implants

    Science.gov (United States)

    Mooney, V.

    1977-01-01

    Review of carbon implants developed by NASA discussed four different types of implants and subsequent improvements. Improvements could be of specific interest to rehabilitation centers and similar organizations.

  6. Are narrow mesons, baryons and dibaryons evidence for multiquark states?

    International Nuclear Information System (INIS)

    Tatischeff, B.; Yonnet, J.

    2000-01-01

    Several narrow structures have been progressively observed since the last fifteen years, in di-baryonic invariant mass spectra or in missing mass spectra. More recently, narrow structures were observed in baryonic and now in mesonic mass spectra. Since these small peaks appear at fixed masses, independently of the experiment, they are associated with real states. There is no room to explain these states within classical nuclear physics taking into account baryonic and mesonic degrees of freedom. An interpretation is proposed, which associate these narrow structures with two coloured quark clusters. (authors)

  7. Degradable Implantate: Entwicklungsbeispiele

    Science.gov (United States)

    Ruffieux, Kurt; Wintermantel, Erich

    Resorbierbare Implantate werden seit mehreren Jahrzehnten in der Implantologie eingesetzt. Bekannt wurden diese Biomaterialien mit dem Aufkommen von sich selbst auflösenden Nahtfäden auf der Basis von synthetisch hergestellten Polylactiden und Polyglycoliden in den 70er Jahren. In einem nächsten Schritt wurden Implantate wie Platten und Schrauben zur Gewebefixation aus den gleichen Biomaterialien hergestellt.

  8. Risks of Breast Implants

    Science.gov (United States)

    ... have a risk of developing a type of cancer called breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) in the breast tissue surrounding the implant. BIA-ALCL is not breast cancer. Women diagnosed with BIA-ALCL may need to ...

  9. Ion implantation of metals

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1976-01-01

    In this part of the paper descriptions are given of the effects of ion implantation on (a) friction and wear in metals; and (b) corrosion of metals. In the study of corrosion, ion implantation can be used either to introduce a constituent that is known to convey corrosion resistance, or more generally to examine the parameters which control corrosion. (U.K.)

  10. Ion implantation into diamond

    International Nuclear Information System (INIS)

    Sato, Susumu

    1994-01-01

    The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)

  11. Origami Wheel Transformer: A Variable-Diameter Wheel Drive Robot Using an Origami Structure.

    Science.gov (United States)

    Lee, Dae-Young; Kim, Sa-Reum; Kim, Ji-Suk; Park, Jae-Jun; Cho, Kyu-Jin

    2017-06-01

    A wheel drive mechanism is simple, stable, and efficient, but its mobility in unstructured terrain is seriously limited. Using a deformable wheel is one of the ways to increase the mobility of a wheel drive robot. By changing the radius of its wheels, the robot becomes able to pass over not only high steps but also narrow gaps. In this article, we propose a novel design for a variable-diameter wheel using an origami-based soft robotics design approach. By simply folding a patterned sheet into a wheel shape, a variable-diameter wheel was built without requiring lots of mechanical parts and a complex assembly process. The wheel's diameter can change from 30 to 68 mm, and it is light in weight at about 9.7 g. Although composed of soft materials (fabrics and films), the wheel can bear more than 400 times its weight. The robot was able to change the wheel's radius in response to terrain conditions, allowing it to pass over a 50-mm gap when the wheel is shrunk and a 50-mm step when the wheel is enlarged.

  12. Retrospective analysis of dental implants placed and restored by advanced prosthodontic residents.

    Science.gov (United States)

    Barias, Pamela A; Lee, Damian J; Yuan, Judy Chia-Chun; Sukotjo, Cortino; Campbell, Stephen D; Knoernschild, Kent L

    2013-02-01

    The purposes of this retrospective clinical review were to: (1) describe the demographics of implant patients, types of implant treatment and implant-supported prostheses in an Advanced Education in Prosthodontic Program, (2) evaluate the survival rate of dental implants placed by prosthodontic residents from 2006 to 2008, and (3) analyze the relationship between resident year of training and implant survival rate. All patients who received dental implants placed by prosthodontic residents from January 2006 to October of 2008 in the Advanced Prosthodontic Program at the University of Illinois at Chicago College of Dentistry were selected for this study. Age, gender, implant diameter, length, implant locations, surgical and restorative detail, and year of prosthodontic residency training were collected and analyzed. Life-table and Kaplan-Meier survival analyses were performed based on implants overall, locations, year of training, and use of a computer-generated surgical guide. A Logrank statistic was performed between implant survival and year of prosthodontic residency training, location, and use of computer-generated surgical guide (α= 0.05). Three hundred and six implants were placed, and of these, seven failed. Life-table and Kaplan-Meier analyses computed a cumulative survival rate (CSR) of 97% for overall implants and implants placed with a computer-generated surgical guide. No statistical difference was found in implant survival rates as a function of year of training (P= 0.85). Dental implants placed by prosthodontic residents had a CSR comparable to previously published studies by other specialties. The year of prosthodontic residency training and implant failure rate did not have any significant relationship. © 2012 by the American College of Prosthodontists.

  13. Retrospective analysis of survival rates and marginal bone loss on short implants in the mandible.

    Science.gov (United States)

    Draenert, Florian G; Sagheb, Keyvan; Baumgardt, Katharina; Kämmerer, Peer W

    2012-09-01

    Short implants have become an interesting alternative to bone augmentation in dental implantology. Design of shorter implants and longer surveillance times are a current research issue. The goal of this study was to show the survival rates of short implants below 9 mm in the partly edentulous mandibular premolar and molar regions with fixed prosthetics. Marginal vertical and 2D bone loss was evaluated additionally. Different implant designs are orientationally evaluated. A total of 247 dental implants with fixed prosthetics (crowns and bridges) in the premolar and molar region of the mandible were evaluated; 47 implants were 9 mm or shorter. Patient data were evaluated to acquire implant survival rates, implant diameter, gender and age. Panoramic X-rays were analysed for marginal bone loss. Average surveillance time was 1327 days. Cumulative survival rate (CSR) of short implants was 98% (1 implants lost) compared to 94% in the longer implants group without significance. Thirty-five of the short implants were Astratech (0 losses) and 12 were Camlog Screw Line Promote Plus (1 loss). Early vertical and two-dimensional marginal bone loss was not significantly different in short and regular length implant group with an average of 0.6 mm and 0.7 mm(2) in short implants over the observation period. Within the limitations of this study, we conclude that short implants with a length of 9 mm or less have equal survival rates compared with longer implants over the observation period of 1-3 years. © 2011 John Wiley & Sons A/S.

  14. Systemic Assessment of Patients Undergoing Dental Implant Surgeries: A Trans- and Post-operative Analysis.

    Science.gov (United States)

    Byakodi, Sanjay; Kumar, Sachin; Reddy, Rajesh Kumar; Kumar, Vipin; Sepolia, Shipra; Gupta, Shivangi; Singh, Harkanwal Preet

    2017-01-01

    Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI) questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1) absolutely not, (2) slightly, (3) somewhat, or (4) very much. All the results were recorded and statistical analyzed by SPSS software. Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality ( n = 38). Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla ( P < 0.001). The difference of average STAI-State subscore before and after the surgery was statistically significant ( P < 0.05; significant). Mandibular dental implants show more clamping (torque) than maxillary dental implants.

  15. Submillimeter Diameter Poly(Vinyl Alcohol) Vascular Graft Patency in Rabbit Model

    Science.gov (United States)

    Cutiongco, Marie F. A.; Kukumberg, Marek; Peneyra, Jonnathan L.; Yeo, Matthew S.; Yao, Jia Y.; Rufaihah, Abdul Jalil; Le Visage, Catherine; Ho, Jackie Pei; Yim, Evelyn K. F.

    2016-01-01

    Microvascular surgery is becoming a prevalent surgical practice. Replantation, hand reconstruction, orthopedic, and free tissue transfer procedures all rely on microvascular surgery for the repair of venous and arterial defects at the millimeter and submillimeter levels. Often, a vascular graft is required for the procedure as a means to bridge the gap between native arteries. While autologous vessels are desired for their bioactivity and non-thrombogenicity, the tedious harvest process, lack of availability, and caliber or mechanical mismatch contribute to graft failure. Thus, there is a need for an off-the-shelf artificial vascular graft that has low thrombogenic properties and mechanical properties matching those of submillimeter vessels. Poly(vinyl alcohol) hydrogel (PVA) has excellent prospects as a vascular graft due to its bioinertness, low thrombogenicity, high water content, and tunable mechanical properties. Here, we fabricated PVA grafts with submillimeter diameter and mechanical properties that closely approximated those of the rabbit femoral artery. In vitro platelet adhesion and microparticle release assay verified the low thrombogenicity of PVA. A stringent proof-of-concept in vivo test was performed by implanting PVA grafts in rabbit femoral artery with multilevel arterial occlusion. Laser Doppler measurements indicated the improved perfusion of the distal limb after implantation with PVA grafts. Moreover, ultrasound Doppler and angiography verified that the submillimeter diameter PVA vascular grafts remained patent for 2 weeks without the aid of anticoagulant or antithrombotics. Endothelial cells were observed in the luminal surface of one patent PVA graft. The advantageous non-thrombogenic and tunable mechanical properties of PVA that are retained even in the submillimeter diameter dimensions support the application of this biomaterial for vascular replacement in microvascular surgery. PMID:27376059

  16. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  17. Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

    Directory of Open Access Journals (Sweden)

    HamidReza Arab

    2015-09-01

    Full Text Available Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3i implant (3i Implant Innovation, Palm Beach Gardens, FL, USA. The evaluations were performed one year after loading. Materials and Methods: A total of 39 implants (23 external hex, 16 internal hex were placed randomly in 23 patients (10 male, 13 female by a submerged approach. None of patients had compromised conditions or parafunctional habits. At placement and at one year after loading, periapical radiographs were taken via the parallel method from the implant sites. Results: Crestal bone loss was -0.712±0.831 mm in implants with an internal hex connection and -0.139±0.505 mm in implants with an external hex connection (P≤0.05. No correlation was found between crestal bone loss and parameters such as age, gender, jaw, implant location (anterior, premolar, or molar, implant diameter, or implant length. Conclusions: Crestal bone loss was greater in patients with internal hex 3i implants than in those with external implants. Similar results in other clinical factors were found between the groups.

  18. Ion implantation into iron

    International Nuclear Information System (INIS)

    Iwaki, Masaya

    1978-01-01

    The distribution of implanted ions in iron, the friction characteristics and the corrosion of iron were studied. The distribution of Ni or Cr ions implanted into mild steel was measured. The accelerated voltage was 150 keV, and the beam current density was about 2 microampere/cm 2 . The measurement was made with an ion microanalyzer. The measured distribution was compared with that of LSS theory. Deep invasion of Ni was seen in the measured distribution. The distribution of Cr ions was different from the distribution calculated by the LSS theory. The relative friction coefficient of mild steel varied according to the dose of implanted Cu or N ions, and to the accelerating voltage. Formation of compound metals on the surfaces of metals by ion-implantation was investigated for the purpose to prevent the corrosion of metals. The resistance of mild steel in which Ni ions were implanted was larger than that of mild steel without any treatment. (Kato, T.)

  19. Effective implantation of light emitting centers by plasma immersion ion implantation and focused ion beam methods into nanosized diamond

    International Nuclear Information System (INIS)

    Himics, L.; Tóth, S.; Veres, M.; Tóth, A.; Koós, M.

    2015-01-01

    Highlights: • Characteristics of nitrogen implantation of nanodiamond using two low ion energy ion implantation methods were compared. • Formation of complex nitrogen-related defect centers was promoted by subsequent helium implantation and heat treatments. • Depth profiles of the implanted ions and the generated vacancies were determined using SRIM calculations. • The presence of nitrogen impurity was demonstrated by Fourier-transform infrared spectroscopic measurements. • A new nitrogen related band was detected in the photoluminescence spectrum of the implanted samples that was attributed to the N3 color center in nanodiamond. - Abstract: Two different implantation techniques, plasma immersion ion implantation and focused ion beam, were used to introduce nitrogen ions into detonation nanodiamond crystals with the aim to create nitrogen-vacancy related optically active centers of light emission in near UV region. Previously samples were subjected to a defect creation process by helium irradiation in both cases. Heat treatments at different temperatures (750 °C, 450 °C) were applied in order to initiate the formation of nitrogen-vacancy related complex centers and to decrease the sp 2 carbon content formed under different treatments. As a result, a relatively narrow and intensive emission band with fine structure at 2.98, 2.83 and 2.71 eV photon energies was observed in the light emission spectrum. It was assigned to the N3 complex defect center. The formation of this defect center can be expected by taking into account the relatively high dose of implanted nitrogen ions and the overlapped depth distribution of vacancies and nitrogen. The calculated depth profiles distribution for both implanted nitrogen and helium by SRIM simulation support this expectation

  20. Comparison of implant component fractures in external and internal type: A 12-year retrospective study.

    Science.gov (United States)

    Yi, Yuseung; Koak, Jai-Young; Kim, Seong-Kyun; Lee, Shin-Jae; Heo, Seong-Joo

    2018-04-01

    The aim of this study was to compare the fracture of implant component behavior of external and internal type of implants to suggest directions for successful implant treatment. Data were collected from the clinical records of all patients who received WARANTEC implants at Seoul National University Dental Hospital from February 2002 to January 2014 for 12 years. Total number of implants was 1,289 and an average of 3.2 implants was installed per patient. Information about abutment connection type, implant locations, platform sizes was collected with presence of implant component fractures and their managements. SPSS statistics software (version 24.0, IBM) was used for the statistical analysis. Overall fracture was significantly more frequent in internal type. The most frequently fractured component was abutment in internal type implants, and screw fracture occurred most frequently in external type. Analyzing by fractured components, screw fracture was the most frequent in the maxillary anterior region and the most abutment fracture occurred in the maxillary posterior region and screw fractures occurred more frequently in NP (narrow platform) and abutment fractures occurred more frequently in RP (regular platform). In external type, screw fracture occurred most frequently, especially in the maxillary anterior region, and in internal type, abutment fracture occurred frequently in the posterior region. placement of an external type implant rather than an internal type is recommended for the posterior region where abutment fractures frequently occur.

  1. Thermal desorption of deuterium implanted into beryllium

    International Nuclear Information System (INIS)

    Markin, A.V.; Chernikov, V.N.; Zakharov, A.P.

    1995-01-01

    By means of TDS measurements it is shown that the desorption of deuterium from Be implanted with 5 keV D ions to fluences, Φ, from 1x10 20 D/m 2 to 1x10 21 D/m 2 proceeds in one high temperature stage B, while at Φ ≥ 1.2x10 21 D/m 2 one more stage A is added. The desorption maximum A is narrow and consists of two peaks A 1 and A 2 at about 460 K and 490 K, respectively. Peak A 1 is attributed to the desorption of deuterium from the walls of opened channels formed under D ion implantation. Peak A 2 is a consequence of the opening of a part of closed bubbles/channels to the outer surface. The position of maximum B shifts noticeably and nonsteadily on the fluence in a range from 850 to 1050 K. The origin of this maximum is the liberation of D atoms bound at vacancy complexes discussed previously by Wampler. The dependence of Tm(B) on the fluence is governed by the interaction of freely migrating D atoms with partly opened or fully closed gas cavity arrangements which are created under temperature ramping, but differently in specimens implanted with D ions to different fluences

  2. The preoperative imaging evaluation for cochlear implantation

    International Nuclear Information System (INIS)

    Liu Zhonglin; Wang Zhenchang; Fu Lin; Li Yong; Xian Junfang; Yang Bentao; Lan Baosen; Li Yongxin; Zheng Jun; Song Yan; Liu Bo; Chen Xueqing; He Haili

    2006-01-01

    Objective: To analyze CT and MRI findings of temporal bone and to evaluate preoperative diagnostic value for cochlear implantation. Methods: One hundred and sixty candidates for cochlear implantation were examined with axial CT scan, 64 of them also with coronal CT scan, and 119 patients with MRI. Results: All of 320 ears were well-aerated, and 206 ears had mastoid cavities extended posteriorly to the sigmoid sinus. The length from posterior-lateral tympanic wall to the outer cortex was (2.34±0.42) mm (left side) and (2.25±0.40) mm (right side) (U=1.887, P 1 and T 2 signal on MRI. The congenital malformations of inner ear occurred in 67 ears, including complete dysplasia in 1 ear, cochlear hypodysplasia in 6 ears, Mondini deformation in 5 ears, enlarged vestibular aqueduct in 40 ears, dysplastic semicircular canal and the vestibulae in 10 ears, and narrowing of internal auditory canal in 5 ears. Conclusion: Preoperative imaging examinations can provide critical information to ensure successful cochlear' implantation. (authors)

  3. Mechanical frequency selectivity of an artificial basilar membrane using a beam array with narrow supports

    International Nuclear Information System (INIS)

    Kim, Sangwon; Jang, Jongmoon; Choi, Hongsoo; Song, Won Joon; Jang, Jeong Hun

    2013-01-01

    The study presented in this paper assessed the frequency selectivity of an artificial basilar membrane (ABM) constructed using a piezoelectric beam array with narrow supports. Three ABM samples were constructed. Each ABM contained 16 beams with various lengths in a one-dimensional array. To experimentally assess the frequency selectivity of the ABM, mechanical vibration induced either by an electrical or an acoustic stimulus was measured with a scanning laser-Doppler vibrometer. The electro-mechanical and acousto-mechanical transfer functions were defined for the same purpose. The tonotopy of each beam array was visualized by post-processing the experimental results. Finite element analyses were conducted to numerically compute the resonance frequencies, identify the associated vibrational modes, and evaluate the harmonic responses of the beams. The influence of the residual stresses existing in the beams was reflected in the geometric models by introducing three different levels of arc-shaped lateral deformations in the beams. The harmonic analyses revealed that each beam of the ABM samples presented independent band-pass characteristics. The experiments and simulations commonly showed a frequency selectivity of the fabricated ABMs in the range of 2–20 kHz. Therefore, the device is suitable for development of a totally implantable artificial cochlea, implementing a mechanical frequency analyzer. This work is part of research to develop a prototype of a totally implantable artificial cochlea. (paper)

  4. Unconstrained tripolar hip implants: effect on hip stability.

    Science.gov (United States)

    Guyen, Olivier; Chen, Qing Shan; Bejui-Hugues, Jacques; Berry, Daniel J; An, Kai-Nan

    2007-02-01

    Tripolar implants were developed to treat unstable total hip arthroplasties. However, there is limited confirmation that they achieve this purpose despite their increasing use. Because they have a larger effective head size, these implants are expected to increase range of motion to impingement and improve stability in situations at risk for impingement compared with conventional implants. We assessed the range of motion to impingement using a tripolar implant mounted to an automated hip simulator using 22.2-mm and 28-mm femoral head sizes. The 22 and 28-mm tripolar implants provided increases of 30.5 degrees in flexion, 15.4 degrees in adduction, and 22.4 degrees in external rotation compared with the conventional 22.2-mm femoral head diameter implant. At the critical position of 90 degrees hip flexion, there was an increase of 45.2 degrees in internal rotation. At 0 degrees and 30 degrees external rotation, extension increases were 18.8 degrees and 7.8 degrees, respectively. Bony impingement was the limiting factor. Tripolar implants increased the arc of motion before impingement in positions at risk for dislocation and are expected to provide greater stability.

  5. Electrical conductivity enhancement of polyethersulfone (PES) by ion implantation

    International Nuclear Information System (INIS)

    Bridwell, L.B.; Giedd, R.E.; Wang Yongqiang; Mohite, S.S.; Jahnke, T.; Brown, I.M.

    1991-01-01

    Amorphous polyethersulfone (PES) films have been implanted with a variety of ions (He, B, C, N and As) at a bombarding energy of 50 keV in the dose range 10 16 -10 17 ions/cm 2 . Surface resistance as a function of dose indicates a saturation effect with a significant difference between He and the other ions used. ESR line shapes in the He implanted samples changed from a mixed Gaussian/Lorentzian to a pure Lorentzian and narrowed with increasing dose. Temperature dependent resistivity indicates an electron hopping mechanism for conduction. Infrared results indicate cross-linking or self-cyclization occurred for all implanted ions with further destruction in the case of As. (orig.)

  6. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  7. What's in a name? Expiratory tracheal narrowing in adults explained

    International Nuclear Information System (INIS)

    Leong, P.; Bardin, P.G.; Lau, K.K.

    2013-01-01

    Tracheomalacia, tracheobronchomalacia, and excessive dynamic airway collapse are all terms used to describe tracheal narrowing in expiration. The first two describe luminal reduction from cartilage softening and the latter refers to luminal reduction from exaggerated posterior membrane movement. Expiratory tracheal narrowing is a frequent occurrence that can cause symptoms of airway obstruction, such as dyspnoea, wheeze, and exercise intolerance. The accurate diagnosis and quantification of expiratory tracheal narrowing has important aetiological, therapeutic, and prognostic implications. The reference standard for diagnosis has traditionally been bronchoscopy; however, this method has significant limitations. Expiratory tracheal disorders are readily detected by four-dimensional dynamic volume multidetector computed tomography (4D-CT), an emerging, non-invasive method that will potentially enable detection and quantification of these conditions. This review discusses the morphological forms of expiratory tracheal narrowing and demonstrates the utility of 4D-CT in the diagnosis, quantification, and treatment of these important conditions

  8. Single frequency narrow linewidth 2 micron laser, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA needs narrow linewidth lasers in the 1.5 or 2 micron wavelength regime for coherent Lidar applications. The laser should be tunable by several nm and frequency...

  9. Subglottic cysts and asymmetrical subglottic narrowing on neck radiograph

    International Nuclear Information System (INIS)

    Holinger, L.D.; Torium, D.M.; Anandappa, E.C.

    1988-01-01

    The congenital subglottic hemangioma typically appears as an asymmetric subglottic narrowing or mass on frontal neck radiograph. Therefore, soft tissue neck radiography has been advocated as a definitive non-operative approach for diagnosing these lesions. However, we have noted similar asymmetric subglottic narrowing in patients with acquired subglottic cysts. These retention cysts occur following long-term intubation in the neonate. The mechanism probably involves subglottic fibrosis which obstructs glands with subsequent cyst formation. Acquired subglottic cysts typically appear as an asymmetric narrowing on frontal or lateral soft tissue neck radiographs. These lesions may produce airway compromise but are effectively treated by forceps or laser removal. Acquired subglottic cysts must be included in the differential diagnosis of asymmetric subglottic narrowing. The definitive diagnosis is made by direct laryngoscopy, not soft tissue neck radiograph. (orig.)

  10. THE TREATMENT OF OPEN- AND NARROW-ANGLE GLAUCOMA

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... glaucoma will be considered: narrow-angle glaucoma. (acute glaucoma) and ... emotional or a physical crisis. The pain is in the distribu- .... ness, not increased pressure, haunts people suffering from glaucoma'.' The saga of ...

  11. Comment on the narrow structure reported by Amaryan et al

    OpenAIRE

    Anghinolfi, M.; Ball, J.; Baltzell, N. A.; Battaglieri, M.; Bedlinskiy, I.; Bellis, M.; Biselli, A. S.; Bookwalter, C.; Boiarinov, S.; Bosted, P.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Chandavar, S.; Cole, P. L.

    2012-01-01

    The CLAS Collaboration provides a comment on the physics interpretation of the results presented in a paper published by M. Amaryan et al. regarding the possible observation of a narrow structure in the mass spectrum of a photoproduction experiment.

  12. Narrow band interference cancelation in OFDM: Astructured maximum likelihood approach

    KAUST Repository

    Sohail, Muhammad Sadiq; Al-Naffouri, Tareq Y.; Al-Ghadhban, Samir N.

    2012-01-01

    This paper presents a maximum likelihood (ML) approach to mitigate the effect of narrow band interference (NBI) in a zero padded orthogonal frequency division multiplexing (ZP-OFDM) system. The NBI is assumed to be time variant and asynchronous

  13. Observation of diameter dependent carrier distribution in nanowire-based transistors

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, A; Hantschel, T; Eyben, P; Verhulst, A S; Rooyackers, R; Vandooren, A; Mody, J; Nazir, A; Leonelli, D; Vandervorst, W, E-mail: Andreas.Schulze@imec.be [IMEC, Kapeldreef 75, 3001 Leuven (Belgium)

    2011-05-06

    The successful implementation of nanowire (NW) based field-effect transistors (FET) critically depends on quantitative information about the carrier distribution inside such devices. Therefore, we have developed a method based on high-vacuum scanning spreading resistance microscopy (HV-SSRM) which allows two-dimensional (2D) quantitative carrier profiling of fully integrated silicon NW-based tunnel-FETs (TFETs) with 2 nm spatial resolution. The key elements of our characterization procedure are optimized NW cleaving and polishing steps, the use of in-house fabricated ultra-sharp diamond tips, measurements in high vacuum and a dedicated quantification procedure accounting for the Schottky-like tip-sample contact affected by surface states. In the case of the implanted TFET source regions we find a strong NW diameter dependence of conformality, junction abruptness and gate overlap, quantitatively in agreement with process simulations. In contrast, the arsenic doped drain regions reveal an unexpected NW diameter dependent dopant deactivation. The observed lower drain doping for smaller diameters is reflected in the device characteristics by lower TFET off-currents, as measured experimentally and confirmed by device simulations.

  14. Construction of tissue-engineered small-diameter vascular grafts in fibrin scaffolds in 30 days.

    Science.gov (United States)

    Gui, Liqiong; Boyle, Michael J; Kamin, Yishai M; Huang, Angela H; Starcher, Barry C; Miller, Cheryl A; Vishnevetsky, Michael J; Niklason, Laura E

    2014-05-01

    Tissue-engineered small-diameter vascular grafts have been developed as a promising alternative to native veins or arteries for replacement therapy. However, there is still a crucial need to improve the current approaches to render the tissue-engineered blood vessels more favorable for clinical applications. A completely biological blood vessel (3-mm inner diameter) was constructed by culturing a 50:50 mixture of bovine smooth muscle cells (SMCs) with neonatal human dermal fibroblasts in fibrin gels. After 30 days of culture under pulsatile stretching, the engineered blood vessels demonstrated an average burst pressure of 913.3±150.1 mmHg (n=6), a suture retention (53.3±15.4 g) that is suitable for implantation, and a compliance (3.1%±2.5% per 100 mmHg) that is comparable to native vessels. These engineered grafts contained circumferentially aligned collagen fibers, microfibrils and elastic fibers, and differentiated SMCs, mimicking a native artery. These promising mechanical and biochemical properties were achieved in a very short culture time of 30 days, suggesting the potential of co-culturing SMCs with fibroblasts in fibrin gels to generate functional small-diameter vascular grafts for vascular reconstruction surgery.

  15. Clinical and Radiologic Outcomes of Submerged and Nonsubmerged Bone-Level Implants with Internal Hexagonal Connections in Immediate Implantation: A 5-Year Retrospective Study.

    Science.gov (United States)

    Wu, Shiyu; Wu, Xiayi; Shrestha, Rachana; Lin, Jinying; Feng, Zhicai; Liu, Yudong; Shi, Yunlin; Huang, Baoxin; Li, Zhipeng; Liu, Quan; Zhang, Xiaocong; Hu, Mingxuan; Chen, Zhuofan

    2018-02-01

    To evaluate the 5-year clinical and radiologic outcome of immediate implantation using submerged and nonsubmerged techniques with bone-level implants and internal hexagonal connections and the effects of potential influencing factors. A total of 114 bone-level implants (XiVE S plus) with internal hexagonal connections inserted into 72 patients were included. Patients were followed up for 5 years. A t-test was used to statistically evaluate the marginal bone loss between the submerged and nonsubmerged groups. The cumulative survival rate (CSR) was calculated according to the life table method and illustrated with Kaplan-Meier survival curves. Comparisons of the CSR between healing protocols, guided bone regeneration, implants with different sites, lengths, and diameters were performed using log-rank tests. The 5-year cumulative implant survival rates with submerged and nonsubmerged healing were 94% and 96%, respectively. No statistically significant differences in terms of marginal bone loss, healing protocol, application of guided bone regeneration, implant site, or length were observed. High CSRs and good marginal bone levels were achieved 5 years after immediate implantation of bone-level implants with internal hexagonal connections using both the submerged and nonsubmerged techniques. Factors such as implant length, site, and application of guided bone regeneration did not have an impact on the long-term success of the implants. © 2017 by the American College of Prosthodontists.

  16. Narrow Framing and Long-Term Care Insurance

    OpenAIRE

    Daniel Gottlieb; Olivia S. Mitchell

    2015-01-01

    We propose a model of narrow framing in insurance and test it using data from a new module we designed and fielded in the Health and Retirement Study. We show that respondents subject to narrow framing are substantially less likely to buy long-term care insurance than average. This effect is distinct from, and much larger than, the effects of risk aversion or adverse selection, and it offers a new explanation for why people underinsure their later-life care needs.

  17. Comparison of proton and phosphorous ion implantation-induced intermixing of InAs/InP quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Barik, S; Tan, H H; Jagadish, C [Department of Electronic Materials Engineering, Research School of Physical Sciences and Engineering, Australian National University, Canberra, Australian Capital Territory 0200 (Australia)

    2007-05-02

    We report and compare proton and phosphorous ion implantation-induced intermixing of InAs/InP quantum dots (QDs). After ion implantation at 20-300 deg. C, the QDs are rapid thermally annealed at 850 deg. C for 30 s. Proton implantation induces less energy shift than P ion implantation for a given concentration of atomic displacements due to the more efficient dynamic annealing of the defects created by protons. The implantation-induced energy shift reaches a maximum value of about 260 meV for a dose of 5 x 10{sup 12} ions cm{sup -2} in the P ion implanted QDs, which also show narrower PL linewidths compared to the proton implanted QDs. We also report the effects of an InGaAs top cap layer on the ion implantation-induced QD intermixing and show that defect production and annihilation processes evolve differently in InGaAs and InP layers and vary with the implantation temperature. When the implantation is performed at higher temperatures, the energy shift of the P ion implanted QDs capped with an InP layer increases due to the reduction in larger defect cluster formation at higher temperatures, while the energy shift of the proton implanted QDs decreases due to increased dynamic annealing irrespective of their cap layers.

  18. Titanium versus zirconia implants supporting maxillary overdentures: three-dimensional finite element analysis.

    Science.gov (United States)

    Osman, Reham B; Elkhadem, Amr H; Ma, Sunyoung; Swain, Michael V

    2013-01-01

    The purpose of this study was to compare the stress and strain occurring in peri-implant bone and implants used to support maxillary overdentures. Three-dimensional finite element analysis (3D FEA) was used to compare one-piece zirconia and titanium implants. Two types of implants were simulated using a 3D FEA model: one-piece zirconia and titanium implants (diameter, 3.8 × 11.5 mm) with 2.25-mm diameter ball abutments. In each simulation four implants were placed bilaterally in the canine/premolar region of an edentulous maxillary model. Static loads were applied axially and 20 degrees buccolingually on the buccal slope of the lingual cusps of posterior teeth of the first quadrant. Von Mises stresses and equivalent strains generated in peri-implant bone and first principal stresses in the implants were calculated. Comparable stress and strain values were shown in the peri-implant bone for both types of implants. The maximum equivalent strain produced in the peri-implant region was mostly within the range for bone augmentation. Under oblique loading, maximum von Mises stresses and equivalent strain were more evident at the neck of the most distal implant on the loaded side. Under axial load, the stress and strain were transferred to the peri-implant bone around the apex of the implant. Maximum tensile stresses that developed for either material were well below their fracture strength. The highest stresses were mainly located at the distobuccal region of the neck for the two implant materials under both loading conditions. From a biomechanical point of view, ceramic implants made from yttrium-stabilized tetragonal polycrystalline zirconia may be a potential alternative to conventional titanium implants for the support of overdentures. This is particularly relevant for a select group of patients with a proven allergy to titanium. Prospective clinical studies are still required to confirm these in vitro results. Different simulations presenting various cortical bone

  19. Ocular Biometrics of Myopic Eyes With Narrow Angles.

    Science.gov (United States)

    Chong, Gabriel T; Wen, Joanne C; Su, Daniel Hsien-Wen; Stinnett, Sandra; Asrani, Sanjay

    2016-02-01

    The purpose of this study was to compare the ocular biometrics between myopic patients with and without narrow angles. Patients with a stable myopic refraction (myopia worse than -1.00 D spherical equivalent) were prospectively recruited. Angle status was assessed using gonioscopy and biometric measurements were performed using an anterior segment optical coherence tomography and an IOLMaster. A total of 29 patients (58 eyes) were enrolled with 13 patients (26 eyes) classified as having narrow angles and 16 patients (32 eyes) classified as having open angles. Baseline demographics of age, sex, and ethnicity did not differ significantly between the 2 groups. The patients with narrow angles were on average older than those with open angles but the difference did not reach statistical significance (P=0.12). The central anterior chamber depth was significantly less in the eyes with narrow angles (P=0.05). However, the average lens thickness, although greater in the eyes with narrow angles, did not reach statistical significance (P=0.10). Refractive error, axial lengths, and iris thicknesses did not differ significantly between the 2 groups (P=0.32, 0.47, 0.15). Narrow angles can occur in myopic eyes. Routine gonioscopy is therefore recommended for all patients regardless of refractive error.

  20. Acquisition and visualization techniques for narrow spectral color imaging.

    Science.gov (United States)

    Neumann, László; García, Rafael; Basa, János; Hegedüs, Ramón

    2013-06-01

    This paper introduces a new approach in narrow-band imaging (NBI). Existing NBI techniques generate images by selecting discrete bands over the full visible spectrum or an even wider spectral range. In contrast, here we perform the sampling with filters covering a tight spectral window. This image acquisition method, named narrow spectral imaging, can be particularly useful when optical information is only available within a narrow spectral window, such as in the case of deep-water transmittance, which constitutes the principal motivation of this work. In this study we demonstrate the potential of the proposed photographic technique on nonunderwater scenes recorded under controlled conditions. To this end three multilayer narrow bandpass filters were employed, which transmit at 440, 456, and 470 nm bluish wavelengths, respectively. Since the differences among the images captured in such a narrow spectral window can be extremely small, both image acquisition and visualization require a novel approach. First, high-bit-depth images were acquired with multilayer narrow-band filters either placed in front of the illumination or mounted on the camera lens. Second, a color-mapping method is proposed, using which the input data can be transformed onto the entire display color gamut with a continuous and perceptually nearly uniform mapping, while ensuring optimally high information content for human perception.

  1. Intramyocardial arterial narrowing in dogs with subaortic stenosis.

    Science.gov (United States)

    Falk, T; Jönsson, L; Pedersen, H D

    2004-09-01

    Earlier studies have described intramyocardial arterial narrowing based on hyperplasia and hypertrophy of the vessel wall in dogs with subaortic stenosis (SAS). In theory, such changes might increase the risk of sudden death, as they seem to do in heart disease in other species. This retrospective pathological study describes and quantifies intramyocardial arterial narrowing in 44 dogs with naturally occurring SAS and in eight control dogs. The majority of the dogs with SAS died suddenly (n=27); nine had died or been euthanased with signs of heart failure and eight were euthanased without clinical signs. Dogs with SAS had significantly narrower intramyocardial arteries (Pdogs. Male dogs and those with more severe hypertrophy had more vessel narrowing (P=0.02 and P=0.02, respectively), whereas dogs with dilated hearts had slightly less pronounced arterial thickening (P=0.01). Arterial narrowing was not related to age, but fibrosis increased with age (P=0.047). Dogs that died suddenly did not have a greater number of arterial changes than other dogs with SAS. This study suggests that most dogs with SAS have intramyocardial arterial narrowing and that the risk of dying suddenly is not significantly related to the overall degree of vessel obliteration.

  2. "COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS"

    Directory of Open Access Journals (Sweden)

    P. Borghei S. Abdi

    2004-08-01

    Full Text Available Performing cochlear implantation in patients with inner ear malformation has always been a matter of dispute. This study was designed to analyze the operative findings,complications, and postoperative performance of patients with inner ear anomalies who underwent cochlear implantation. Six patients with inner ear malformations underwent implantation in our academic tertiary referral center from 1997 to 2002. The average follow-up period was 27 months. Malformations included one incomplete partition, one common cavity, one narrow internal acoustic canal (IAC in a patient with Riley-Day syndrome and 3 cases of large vestibular aqueduct. All received multi-channel implants either Nucleus 22 or Clarion device. Facial nerve was anomalous in 2 cases. CSF gusher occurred in 4 patients, which was controlled with packing the cochleostomy site. In all cases, the full length of electrode array was inserted, except one with Mondini's dysplasia where insertion failed in the first operation and was referred to another center for a successful surgery on the opposite ear. No other surgical complications were encountered. In 4 cases, all the 22 electrodes could be activated. All patients showed improved hearing performance after implantation. Four showed open-set speech recognition. The one with narrow IAC showed improved awareness to environmental sounds. In the other case (common cavity, the perception tests could not be performed because of very young age. Cochlear implantation in patients with inner ear malformations is a successful way of rehabilitation, although complications should be expected and auditory responses may be highly variable and relatively moderate.

  3. Prevalence of sinus floor elevation procedures and survival rates of implants placed in the posterior maxilla

    Directory of Open Access Journals (Sweden)

    Ceyda Ozçakır Tomruk

    2016-01-01

    Full Text Available The aim of this study was to assess the prevalence of sinus-lifting procedures and survival rates of implants placed in the posterior maxilla. This retrospective chart review examined consecutive patients with tooth/teeth loss in the posterior maxilla between 2008 and 2012 treated with sinus lift, when needed, and implant insertion. Demographic variables, health status, residual alveolar bone height, augmentation types, the implant position, diameter and height, and implant failure, prosthesis types, and the marginal bone loss were recorded. The study included 302 patients at a mean age of 5.2 years, who received a total of 609 dental implants. A total of 380 (62.3% implants were inserted in native areas, 203 (33.3% ones in external sinus-lifted areas and 26 (4.4% ones in internal lifted areas. The survival rate in native or internal lifted areas were 100% and 95.6% in external sinus lifted ones (10 implant failures/203 implants. Almost half of the implants were examined radiologically with a mean duration of 30 months and the mean marginal bone loss was 0.64 ± 1.2 mm. The results showed that the survival rates of native bone and the internal sinus lifting were slightly higher than that of external sinus lifting. Implants placed with sinus augmentation exhibited more marginal bone loss than implants in native bone.

  4. Analysis of the causes of dental implant fracture: A retrospective clinical study.

    Science.gov (United States)

    Stoichkov, Biser; Kirov, Dimitar

    2018-01-01

    Fracture of osseointegrated dental implants is the most severe mechanical complication. The aim of the present study was to analyze possible causative factors for implant body fracture. One hundred and one patients with 218 fitted implants and a follow-up period of 3 to 10 years were studied. Factors associated with biomechanical and physiologic overloading such as parafunctional activity (eg, bruxism), occlusion, and cantilevers, and factors related to the planning of the dental prosthesis, available bone volume, implant area, implant diameter, number of implants, and their inclination were tracked. The impact of their effect was analyzed using the Bonferroni-corrected post-hoc Mann-Whitney test for each group. The incidence of dental implant fracture was 2.3% in the investigated cases. Improper treatment planning, bruxism, and time of the complication setting in were the main factors leading to this complication. Typical size effect was established only for available bruxism, occlusal errors, and their activity duration. These complications were observed most often with single crown prostheses, and in combination with parafunctional activities such as bruxism and lack of implant-protected occlusion. Occlusal overload due to bruxism or inappropriate or inadequate occlusion as a single factor or a combination of these factors during the first years after the functional load can cause implant fracture. Fracture of the implant body more frequently occurred with single crowns than with other implant-supported fixed dental prostheses.

  5. 3D finite element analysis of immediate loading of single wide versus double implants for replacing mandibular molar

    Directory of Open Access Journals (Sweden)

    Shrikar R Desai

    2013-01-01

    Full Text Available Purpose: The purpose of this finite element study was to compare the stresses, strains, and displacements of double versus single implant in immediate loading for replacing mandibular molar. Materials and Methods: Two 3D FEM (finite element method models were made to simulate implant designs. The first model used 5-mm-wide diameter implant to support a single molar crown. The second model used 3.75-3.75 double implant design. Anisotropic properties were assigned to bone model. Each model was analyzed with single force magnitude (100 N in vertical axis. Results: This FEM study suggested that micromotion can be controlled better for double implants compared to single wide-diameter implants. The Von Mises stress for double implant showed 74.44% stress reduction compared to that of 5-mm implant. The Von Mises elastic strain was reduced by 61% for double implant compared to 5-mm implant. Conclusion: Within the limitations of the study, when the mesiodistal space for artificial tooth is more than 12.5 mm, under immediate loading, the double implant support should be considered.

  6. Implants for orthodontic anchorage

    Science.gov (United States)

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  7. Maintenance in dental implants

    Directory of Open Access Journals (Sweden)

    Giselle Póvoa Gomes

    2008-01-01

    Full Text Available In implants, maintenance is a decisive factor for obtaining success when implant supported overdentures and dentures are used. The present stud presents, a clinical case of a patient, a 70 year-old white man, with a completely edentulous mandibular alveolar ridge, severe bone resorption with presence of basal bone only, and absence of vestibule. Initially, treatment consisted of the placement of a mandibular overdenture, supported on three implants in the anterior inter-foramen region, as the left implant was transfixed in the basal bone of 2 to 3 millimeters. Eleven years later, another two implants were placed in the anterior area and an immediate load was performed up to the first molars, for the placement of an implant supported fixed. Throughout the entire treatment, meticulous maintenance was carried out, with follow-up for fourteen years, interrupted by the patient’s death. From the third month after the opening the three implants initially placed, the presence of keratinized mucosa, definition of the vestibule, maturation of the alveolar ridge and bone formation in the mento region were observed. It was concluded that good planning, allied to mastery of the technique and adequate maintenance were the prerequisites necessary for obtaining favorable results, success of the present case, and for the patient to have a better quality of life.

  8. Nanotechnology for dental implants.

    Science.gov (United States)

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  9. Brain Arterial Diameters as a Risk Factor for Vascular Events

    OpenAIRE

    Gutierrez, Jose; Cheung, Ken; Bagci, Ahmet; Rundek, Tatjana; Alperin, Noam; Sacco, Ralph L; Wright, Clinton B; Elkind, Mitchell S V

    2015-01-01

    Background Arterial luminal diameters are routinely used to assess for vascular disease. Although small diameters are typically considered pathological, arterial dilatation has also been associated with disease. We hypothesize that extreme arterial diameters are biomarkers of the risk of vascular events. Methods and Results Participants in the Northern Manhattan Study who had a time-of-flight magnetic resonance angiography were included in this analysis (N=1034). A global arterial Z-score, ca...

  10. Bruxism and dental implant failures: a multilevel mixed effects parametric survival analysis approach.

    Science.gov (United States)

    Chrcanovic, B R; Kisch, J; Albrektsson, T; Wennerberg, A

    2016-11-01

    Recent studies have suggested that the insertion of dental implants in patients being diagnosed with bruxism negatively affected the implant failure rates. The aim of the present study was to investigate the association between the bruxism and the risk of dental implant failure. This retrospective study is based on 2670 patients who received 10 096 implants at one specialist clinic. Implant- and patient-related data were collected. Descriptive statistics were used to describe the patients and implants. Multilevel mixed effects parametric survival analysis was used to test the association between bruxism and risk of implant failure adjusting for several potential confounders. Criteria from a recent international consensus (Lobbezoo et al., J Oral Rehabil, 40, 2013, 2) and from the International Classification of Sleep Disorders (International classification of sleep disorders, revised: diagnostic and coding manual, American Academy of Sleep Medicine, Chicago, 2014) were used to define and diagnose the condition. The number of implants with information available for all variables totalled 3549, placed in 994 patients, with 179 implants reported as failures. The implant failure rates were 13·0% (24/185) for bruxers and 4·6% (155/3364) for non-bruxers (P bruxism was a statistically significantly risk factor to implant failure (HR 3·396; 95% CI 1·314, 8·777; P = 0·012), as well as implant length, implant diameter, implant surface, bone quantity D in relation to quantity A, bone quality 4 in relation to quality 1 (Lekholm and Zarb classification), smoking and the intake of proton pump inhibitors. It is suggested that the bruxism may be associated with an increased risk of dental implant failure. © 2016 John Wiley & Sons Ltd.

  11. Ion implantation for microelectronics

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1977-01-01

    Ion implantation has proved to be a versatile and efficient means of producing microelectronic devices. This review summarizes the relevant physics and technology and assesses the advantages of the method. Examples are then given of widely different device structures which have been made by ion implantation. While most of the industrial application has been in silicon, good progress continues to be made in the more difficult field of compound semiconductors. Equipment designed for the industrial ion implantation of microelectronic devices is discussed briefly. (Auth.)

  12. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  13. Database and prediction model for CANDU pressure tube diameter

    Energy Technology Data Exchange (ETDEWEB)

    Jung, J.Y.; Park, J.H. [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of)

    2014-07-01

    The pressure tube (PT) diameter is basic data in evaluating the CCP (critical channel power) of a CANDU reactor. Since the CCP affects the operational margin directly, an accurate prediction of the PT diameter is important to assess the operational margin. However, the PT diameter increases by creep owing to the effects of irradiation by neutron flux, stress, and reactor operating temperatures during the plant service period. Thus, it has been necessary to collect the measured data of the PT diameter and establish a database (DB) and develop a prediction model of PT diameter. Accordingly, in this study, a DB for the measured PT diameter data was established and a neural network (NN) based diameter prediction model was developed. The established DB included not only the measured diameter data but also operating conditions such as the temperature, pressure, flux, and effective full power date. The currently developed NN based diameter prediction model considers only extrinsic variables such as the operating conditions, and will be enhanced to consider the effect of intrinsic variables such as the micro-structure of the PT material. (author)

  14. Electronic transport behavior of diameter-graded Ag nanowires

    International Nuclear Information System (INIS)

    Wang Xuewei; Yuan Zhihao

    2010-01-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  15. Electronic transport behavior of diameter-graded Ag nanowires

    Science.gov (United States)

    Wang, Xue Wei; Yuan, Zhi Hao

    2010-05-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  16. Validation of system codes RELAP5 and SPECTRA for natural convection boiling in narrow channels

    Energy Technology Data Exchange (ETDEWEB)

    Stempniewicz, M.M., E-mail: stempniewicz@nrg.eu; Slootman, M.L.F.; Wiersema, H.T.

    2016-10-15

    Highlights: • Computer codes RELAP5/Mod3.3 and SPECTRA 3.61 validated for boiling in narrow channels. • Validated codes can be used for LOCA analyses in research reactors. • Code validation based on natural convection boiling in narrow channels experiments. - Abstract: Safety analyses of LOCA scenarios in nuclear power plants are performed with so called thermal–hydraulic system codes, such as RELAP5. Such codes are validated for typical fuel geometries applied in nuclear power plants. The question considered by this article is if the codes can be applied for LOCA analyses in research reactors, in particular exceeding CHF in very narrow channels. In order to answer this question, validation calculations were performed with two thermal–hydraulic system codes: RELAP and SPECTRA. The validation was based on natural convection boiling in narrow channels experiments, performed by Prof. Monde et al. in the years 1990–2000. In total 42 vertical tube and annulus experiments were simulated with both codes. A good agreement of the calculated values with the measured data was observed. The main conclusions are: • The computer codes RELAP5/Mod 3.3 (US NRC version) and SPECTRA 3.61 have been validated for natural convection boiling in narrow channels using experiments of Monde. The dimensions applied in the experiments were performed for a range that covers the values observed in typical research reactors. Therefore it is concluded that both codes are validated and can be used for LOCA analyses in research reactors, including natural convection boiling. The applicability range of the present validation is: hydraulic diameters of 1.1 ⩽ D{sub hyd} ⩽ 9.0 mm, heated lengths of 0.1 ⩽ L ⩽ 1.0 m, pressures of 0.10 ⩽ P ⩽ 0.99 MPa. In most calculations the burnout was predicted to occur at lower power than that observed in the experiments. In several cases the burnout was observed at higher power. The overprediction was not larger than 16% in RELAP and 15% in

  17. Hydroxyapatite implants with designed internal architecture.

    Science.gov (United States)

    Chu, T M; Halloran, J W; Hollister, S J; Feinberg, S E

    2001-06-01

    Porous hydroxyapatite (HA) has been used as a bone graft material in the clinics for decades. Traditionally, the pores in these HAs are either obtained from the coralline exoskeletal patterns or from the embedded organic particles in the starting HA powder. Both processes offer very limited control on the pore structure. A new method for manufacturing porous HA with designed pore channels has been developed. This method is essentially a lost-mold technique with negative molds made with Stereolithography and a highly loaded curable HA suspension as the ceramic carrier. Implants with designed channels and connection patterns were first generated from a Computer-Aided-Design (CAD) software and Computer Tomography (CT) data. The negative images of the designs were used to build the molds on a stereolithography apparatus with epoxy resins. A 40 vol% HA suspension in propoxylated neopentyl glycol diacrylate (PNPGDA) and iso-bornyl acrylate (IBA) was formulated. HA suspension was cast into the epoxy molds and cured into solid at 85 degrees C. The molds and acrylate binders were removed by pyrolysis, followed by HA green body sintering. With this method, implants with six different channel designs were built successfully and the designed channels were reproduced in the sintered HA implants. The channels created in the sintered HA implants were between 366 microm and 968 microm in diameter with standard deviations of 50 microm or less. The porosity created by the channels were between 26% and 52%. The results show that HA implants with designed connection pattern and well controlled channel size can be built with the technique developed in this study. Copyright 2001 Kluwer Academic Publishers

  18. Imaging spectrophotometry of ionized gas in NGC 1068. I - Kinematics of the narrow-line region

    Science.gov (United States)

    Cecil, Gerald; Bland, Jonathan; Tully, R. Brent

    1990-01-01

    The kinematics of collisionally excited forbidden N II 6548, 6583 across the inner 1 arcmin diameter of the nearby Seyfert galaxy NGC 1068 is mapped using an imaging Fabry-Perot interferometer and low-noise CCD. The stack of monochromatic images, which spatially resolved the high-velocity gas, was analyzed for kinematic and photometric content. Profiles agree well with previous long-slit work, and their complete spatial coverage makes it possible to constrain the gas volume distribution. It is found that the narrow-line region is distributed in a thick center-darkened, line-emitting cylinder that envelopes the collimated radio jet. Three distinct kinematic subsystems, of which the cylinder is composed, are discussed in detail. Detailed behavior of the emission-line profiles, at the few points in the NE quadrant with simple kinematics, argues that the ionized gas develops a significant component of motion perpendicular to the jet axis.

  19. A narrow open tubular column for high efficiency liquid chromatographic separation.

    Science.gov (United States)

    Chen, Huang; Yang, Yu; Qiao, Zhenzhen; Xiang, Piliang; Ren, Jiangtao; Meng, Yunzhu; Zhang, Kaiqi; Juan Lu, Joann; Liu, Shaorong

    2018-04-30

    We report a great feature of open tubular liquid chromatography when it is run using an extremely narrow (e.g., 2 μm inner diameter) open tubular column: more than 10 million plates per meter can be achieved in less than 10 min and under an elution pressure of ca. 20 bar. The column is coated with octadecylsilane and both isocratic and gradient separations are performed. We reveal a focusing effect that may be used to interpret the efficiency enhancement. We also demonstrate the feasibility of using this technique for separating complex peptide samples. This high-resolution and fast separation technique is promising and can lead to a powerful tool for trace sample analysis.

  20. Surface improvement for inside surface of small diameter pipes by laser cladding technique

    International Nuclear Information System (INIS)

    Irisawa, Toshio; Morishige, Norio; Umemoto, Tadahiro; Ono, Kazumichi; Hamaoka, Tadashi; Tanaka, Atsushi

    1991-01-01

    A laser cladding technique has been used for surface improvement in controlling the composition of a metal surface. Recent high power YAG laser development gives an opportunity to use this laser cladding technique for various applications. A YAG laser beam can be transmitted through an optical fiber for a long distance and through narrow spaces. YAG laser cladding was studied for developing alloy steel to prevent stress corrosion cracking in austenitic stainless steel piping. In order to make a cladding layer, mixed metal powder was on the inside surface of the piping using an organic binder. Subsequently the powder beds were melted with a YAG laser beam transmitted through an optical fiber. This paper introduces the Laser cladding technique for surface improvement for the inside surface of a small diameter pipe. (author)

  1. Does Physical Fitness Buffer the Relationship between Psychosocial Stress, Retinal Vessel Diameters, and Blood Pressure among Primary Schoolchildren?

    Science.gov (United States)

    Endes, Katharina; Herrmann, Christian; Colledge, Flora; Brand, Serge; Donath, Lars; Faude, Oliver; Pühse, Uwe; Hanssen, Henner; Zahner, Lukas

    2016-01-01

    Background. Strong evidence exists showing that psychosocial stress plays an important part in the development of cardiovascular diseases. Because physical inactivity is associated with less favourable retinal vessel diameter and blood pressure profiles, this study explores whether physical fitness is able to buffer the negative effects of psychosocial stress on retinal vessel diameters and blood pressure in young children. Methods. 325 primary schoolchildren (51% girls, Mage = 7.28 years) took part in this cross-sectional research project. Retinal arteriolar diameters, retinal venular diameters, arteriolar to venular ratio, and systolic and diastolic blood pressure were assessed in all children. Interactions terms between physical fitness (performance in the 20 m shuttle run test) and four indicators of psychosocial stress (parental reports of critical life events, family, peer and school stress) were tested in a series of hierarchical regression analyses. Results. Critical life events and family, peer, and school-related stress were only weakly associated with retinal vessel diameters and blood pressure. No support was found for a stress-buffering effect of physical fitness. Conclusion. More research is needed with different age groups to find out if and from what age physical fitness can protect against arteriolar vessel narrowing and the occurrence of other cardiovascular disease risk factors. PMID:27795958

  2. A CHF Model in Narrow Gaps under Saturated Boiling

    International Nuclear Information System (INIS)

    Park, Suki; Kim, Hyeonil; Park, Cheol

    2014-01-01

    Many researchers have paid a great attention to the CHF in narrow gaps due to enormous industrial applications. Especially, a great number of researches on the CHF have been carried out in relation to nuclear safety issues such as in-vessel retention for nuclear power plants during a severe accident. Analytical studies to predict the CHF in narrow gaps have been also reported. Yu et al. (2012) developed an analytical model to predict the CHF on downward facing and inclined heaters based on the model of Kandlikar et al. (2001) for an upward facing heater. A new theoretical model is developed to predict the CHF in narrow gaps under saturated pool boiling. This model is applicable when one side of coolant channels or both sides are heated including the effects of heater orientation. The present model is compared with the experimental CHF data obtained in narrow gaps. A new analytical CHF model is proposed to predict CHF for narrow gaps under saturated pool boiling. This model can be applied to one-side or two-sides heating surface and also consider the effects of heater orientation on CHF. The present model is compared with the experimental data obtained in narrow gaps with one heater. The comparisons indicate that the present model shows a good agreement with the experimental CHF data in the horizontal annular tubes. However, it generally under-predicts the experimental data in the narrow rectangular gaps except the data obtained in the gap thickness of 10 mm and the horizontal downward facing heater

  3. The underdilation of nitinol stents at TIPS implantation: Solution or illusion?

    Energy Technology Data Exchange (ETDEWEB)

    Mollaiyan, Ashkan [University Hospital, Department of Radiology, Hugstetterstrasse 55, 79106 Freiburg (Germany); Bettinger, Dominik [University Hospital, Department of Gastroenterology, Hugstetterstrasse 55, 79106 Freiburg (Germany); Berta-Ottenstein-Programme, Faculty of Medicine, University of Freiburg (Germany); Rössle, Martin, E-mail: Martin-Roessle@t-online.de [University Hospital, Department of Gastroenterology, Hugstetterstrasse 55, 79106 Freiburg (Germany); Praxiszentrum für Gastroenterologie, Bertoldstrasse 48, 79098 Freiburg (Germany)

    2017-04-15

    Purpose: This study investigates the behaviour of self-expanding nitinol stents at the time of TIPS-implantation and thereafter. Methods: Hundred consecutive patients with cirrhosis receiving a TIPS revision were included. The smallest stent diameter was measured radiologically immediately after implantation and before shunt revision. Accuracy of the measurement was assessed by comparing the nominal stent diameter with the largest stent diameter measured at the time of revision. Results: Pearson correlation between largest measured and nominal diameters was excellent (r = 0.952, p < 0.001) showing that measurements are accurate. At TIPS implantation all stents were markedly underdilated reaching only 76–92% of their nominal diameter. Smallest measured diameters were similar (8 mm) irrespective of the nominal diameter (8, 9, 10 mm) of the stent. In addition, smallest diameters of 10 mm stents were similar irrespective whether 8, 9 or 10 mm balloons were used. During a mean follow-up of 12.7 ± 17.8 months (median 3 months, range 1–81) stents expanded by 0.5–1.6 mm dependent on the nominal stent size (8, 9, 10 mm) and the grade of primary underdilation. No significant difference was found between Viatorr and bare stents. Conclusions: At TIPS-implantation, the compliance of the surrounding tissue predominantly determines the stent diameter. The nominal size of the stent or the dilatation balloon has little influence. Accurate adjustment of a desired pressure gradient is, therefore, not possible. During follow-up, stents expand towards their nominal diameter questioning the usefulness of underdilation.

  4. The underdilation of nitinol stents at TIPS implantation: Solution or illusion?

    International Nuclear Information System (INIS)

    Mollaiyan, Ashkan; Bettinger, Dominik; Rössle, Martin

    2017-01-01

    Purpose: This study investigates the behaviour of self-expanding nitinol stents at the time of TIPS-implantation and thereafter. Methods: Hundred consecutive patients with cirrhosis receiving a TIPS revision were included. The smallest stent diameter was measured radiologically immediately after implantation and before shunt revision. Accuracy of the measurement was assessed by comparing the nominal stent diameter with the largest stent diameter measured at the time of revision. Results: Pearson correlation between largest measured and nominal diameters was excellent (r = 0.952, p < 0.001) showing that measurements are accurate. At TIPS implantation all stents were markedly underdilated reaching only 76–92% of their nominal diameter. Smallest measured diameters were similar (8 mm) irrespective of the nominal diameter (8, 9, 10 mm) of the stent. In addition, smallest diameters of 10 mm stents were similar irrespective whether 8, 9 or 10 mm balloons were used. During a mean follow-up of 12.7 ± 17.8 months (median 3 months, range 1–81) stents expanded by 0.5–1.6 mm dependent on the nominal stent size (8, 9, 10 mm) and the grade of primary underdilation. No significant difference was found between Viatorr and bare stents. Conclusions: At TIPS-implantation, the compliance of the surrounding tissue predominantly determines the stent diameter. The nominal size of the stent or the dilatation balloon has little influence. Accurate adjustment of a desired pressure gradient is, therefore, not possible. During follow-up, stents expand towards their nominal diameter questioning the usefulness of underdilation.

  5. Breast Reconstruction with Implants

    Science.gov (United States)

    ... your surgical options and discuss the advantages and disadvantages of implant-based reconstruction, and may show you ... Policy Notice of Privacy Practices Notice of Nondiscrimination Advertising Mayo Clinic is a not-for-profit organization ...

  6. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    The current paper presents a state-of-the-art review in the field of ion implantation of polymers. Numerous published studies of polymers modified by ion beams are analysed. General aspects of ion stopping, latent track formation and changes of structure and composition of organic materials...... are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...... is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  7. Precipitation processes in implanted materials

    International Nuclear Information System (INIS)

    Borders, J.A.

    1978-01-01

    Ion implantation is a nonequilibrium process. It is possible to implant materials with impurities to concentration levels which exceed the solid solubilities. The return of the system to thermodynamic equilibrium is often accomplished by precipitation of the implanted species or a compound involving atoms of both the host and the implanted species. This may involve long time scales when taking place at room temperature or it may take place during the implantation

  8. Small diameter electrospun silk fibroin vascular grafts: Mechanical properties, in vitro biodegradability, and in vivo biocompatibility.

    Science.gov (United States)

    Catto, Valentina; Farè, Silvia; Cattaneo, Irene; Figliuzzi, Marina; Alessandrino, Antonio; Freddi, Giuliano; Remuzzi, Andrea; Tanzi, Maria Cristina

    2015-09-01

    To overcome the drawbacks of autologous grafts currently used in clinical practice, vascular tissue engineering represents an alternative approach for the replacement of small diameter blood vessels. In the present work, the production and characterization of small diameter tubular matrices (inner diameter (ID)=4.5 and 1.5 mm), obtained by electrospinning (ES) of Bombyx mori silk fibroin (SF), have been considered. ES-SF tubular scaffolds with ID=1.5 mm are original, and can be used as vascular grafts in pediatrics or in hand microsurgery. Axial and circumferential tensile tests on ES-SF tubes showed appropriate properties for the specific application. The burst pressure and the compliance of ES-SF tubes were estimated using the Laplace's law. Specifically, the estimated burst pressure was higher than the physiological pressures and the estimated compliance was similar or higher than that of native rat aorta and Goretex® prosthesis. Enzymatic in vitro degradation tests demonstrated a decrease of order and crystallinity of the SF outer surface as a consequence of the enzyme activity. The in vitro cytocompatibility of the ES-SF tubes was confirmed by the adhesion and growth of primary porcine smooth muscle cells. The in vivo subcutaneous implant into the rat dorsal tissue indicated that ES-SF matrices caused a mild host reaction. Thus, the results of this investigation, in which comprehensive morphological and mechanical aspects, in vitro degradation and in vitro and in vivo biocompatibility were considered, indicate the potential suitability of these ES-SF tubular matrices as scaffolds for the regeneration of small diameter blood vessels. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels

    International Nuclear Information System (INIS)

    Islam, M.S.; Hino, Ryutaro; Haga, Katsuhiro; Sudo, Yukio; Monde, Masanori.

    1997-03-01

    Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m 2 generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher heat flux up to 12 MW/m 2 could be removed from the rib-roughened surface without flow boiling which induces flow instability; but pressure drop reaches about 1.8 MPa. Correlations obtained by air-flow experiments have showed lower heat transfer performance with the water-flow conditions. The experimental apparatus was proposed for further investigation on heat transfer augmentation in very narrow channels under water-flow conditions. This report presents the evaluation results and an outline of the test apparatus. (author)

  10. Isotachophoresis system having larger-diameter channels flowing into channels with reduced diameter and with selectable counter-flow

    Energy Technology Data Exchange (ETDEWEB)

    Mariella, Jr., Raymond P.

    2018-03-06

    An isotachophoresis system for separating a sample containing particles into discrete packets including a flow channel, the flow channel having a large diameter section and a small diameter section; a negative electrode operably connected to the flow channel; a positive electrode operably connected to the flow channel; a leading carrier fluid in the flow channel; a trailing carrier fluid in the flow channel; and a control for separating the particles in the sample into discrete packets using the leading carrier fluid, the trailing carrier fluid, the large diameter section, and the small diameter section.

  11. Microscopic Study of Surface Microtopographic Characteristics of Dental Implants

    Science.gov (United States)

    Sezin, M.; Croharé, L.; Ibañez, J.C.

    2016-01-01

    Objective: To determine and compare the micro topographic characteristics of dental implants submitted to different surface treatments, using scanning electron microscopy (SEM). Materials and Methods: Implants were divided into 7 groups of 3 specimens each, according to the surface treatment used: group 1: Osseotite, BIOMET 3i; group 2: SLA surface, Institut Straumann AG; group 3: Oxalife surface, Tree-Oss implant; group 4: B&W implant surface; group 5: Q-implant surface; group 6: ML implant surface; group 7: RBM surface, Rosterdent implant. The surfaces were examined under SEM (Carl Zeiss FE-SEM-SIGMA). Image Proplus software was used to determine the number and mean diameter of pores per area unit (mm). The data obtained were analyzed with the Mann-Whitney test. A confocal laser microscope (LEXT-OLS4100 Olympus) was used to conduct the comparative study of surface roughness (Ra). Data were analyzed using Tukey's HSD test. Results: The largest average pore diameter calculated in microns was found in group 5 (3.45 µm+/-1.91) while the smallest in group 7 (1.47µm+/-1.29). Significant differences were observed among each one of the groups studied (p<0.05). The largest number of pores/mm2 was found in group 2 (229343) and the smallest number in group 4 (10937). Group 2 showed significant differences regarding the other groups (p<0.05). The greatest roughness (Ra) was observed in group 2 (0.975µm+/-0.115) and the smallest in group 4 (0.304µm+/-0.063). Group 2 was significantly different from the other groups (p<0.05). Conclusion: The micro topography observed in the different groups presented dissimilar and specific features, depending on the chemical treatment used for the surfaces.. PMID:27335615

  12. Quantitative ion implantation

    International Nuclear Information System (INIS)

    Gries, W.H.

    1976-06-01

    This is a report of the study of the implantation of heavy ions at medium keV-energies into electrically conducting mono-elemental solids, at ion doses too small to cause significant loss of the implanted ions by resputtering. The study has been undertaken to investigate the possibility of accurate portioning of matter in submicrogram quantities, with some specific applications in mind. The problem is extensively investigated both on a theoretical level and in practice. A mathematical model is developed for calculating the loss of implanted ions by resputtering as a function of the implanted ion dose and the sputtering yield. Numerical data are produced therefrom which permit a good order-of-magnitude estimate of the loss for any ion/solid combination in which the ions are heavier than the solid atoms, and for any ion energy from 10 to 300 keV. The implanted ion dose is measured by integration of the ion beam current, and equipment and techniques are described which make possible the accurate integration of an ion current in an electromagnetic isotope separator. The methods are applied to two sample cases, one being a stable isotope, the other a radioisotope. In both cases independent methods are used to show that the implantation is indeed quantitative, as predicted. At the same time the sample cases are used to demonstrate two possible applications for quantitative ion implantation, viz. firstly for the manufacture of calibration standards for instrumental micromethods of elemental trace analysis in metals, and secondly for the determination of the half-lives of long-lived radioisotopes by a specific activity method. It is concluded that the present study has advanced quantitative ion implantation to the state where it can be successfully applied to the solution of problems in other fields

  13. Ion implantation - an introduction

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1986-01-01

    Ion implantation is a widely used technique with a literature that covers semiconductor production, surface treatments of steels, corrosion resistance, catalysis and integrated optics. This brief introduction outlines advantages of the technique, some aspects of the underlying physics and examples of current applications. Ion implantation is already an essential part of semiconductor technology while in many other areas it is still in an early stage of development. The future scope of the subject is discussed. (author)

  14. Taylor dispersion of colloidal particles in narrow channels

    NARCIS (Netherlands)

    Sane, J.; Padding, J.T.; Louis, A.A.

    2015-01-01

    Special issue in Honor of Jean-Pierre Hansen We use a mesoscopic particle-based simulation technique to study the classic convection-diffusion problem of Taylor dispersion for colloidal discs in confined flow. When the disc diameter becomes non-negligible compared to the diameter of the pipe, there

  15. Contraceptive implants: current perspectives

    Directory of Open Access Journals (Sweden)

    Rowlands S

    2014-09-01

    Full Text Available Sam Rowlands,1,2 Stephen Searle3 1Centre of Postgraduate Medical Research and Education, School of Health and Social Care, Bournemouth University, Bournemouth, United Kingdom; 2Dorset HealthCare, Bournemouth, United Kingdom; 3Sexual Health Services, Chesterfield, United KingdomAbstract: Progestin-only contraceptive implants are a highly cost-effective form of long-acting reversible contraception. They are the most effective reversible contraceptives and are of a similar effectiveness to sterilization. Pregnancies are rare in women using this method of contraception, and those that do occur must be fully investigated, with an ultrasound scan of the arm and serum etonogestrel level if the implant cannot be located. There are very few contraindications to use of implants, and they have an excellent safety profile. Both acceptability and continuation with the method are high. Noncontraceptive benefits include improvements in dysmenorrhea, ovulatory pain, and endometriosis. Problematic bleeding is a relatively common adverse effect that must be covered in preinsertion information-giving and supported adequately if it occurs. Recognized training for both insertion and removal should be undertaken. Care needs to be taken at both insertion and removal to avoid neurovascular injury. Implants should always be palpable; if they are not, noninsertion should be assumed until disproven. Etonogestrel implants are now radiopaque, which aids localization. Anticipated difficult removals should be performed by specially trained experts. Keywords: contraceptive, subdermal implant, etonogestrel, levonorgestrel, progestin-only, long-acting reversible contraception

  16. Anodized dental implant surface

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available Purpose: Anodized implants with moderately rough surface were introduced around 2000. Whether these implants enhanced biologic effect to improve the environment for better osseointegration was unclear. The purpose of this article was to review the literature available on anodized surface in terms of their clinical success rate and bone response in patients till now. Materials and Methods: A broad electronic search of MEDLINE and PubMed databases was performed. A focus was made on peer-reviewed dental journals. Only articles related to anodized implants were included. Both animal and human studies were included. Results: The initial search of articles resulted in 581 articles on anodized implants. The initial screening of titles and abstracts resulted in 112 full-text papers; 40 animal studies, 16 studies on cell adhesion and bacterial adhesion onto anodized surfaced implants, and 47 human studies were included. Nine studies, which do not fulfill the inclusion criteria, were excluded. Conclusions: The long-term studies on anodized surface implants do favor the surface, but in most of the studies, anodized surface is compared with that of machined surface, but not with other surfaces commercially available. Anodized surface in terms of clinical success rate in cases of compromised bone and immediately extracted sockets has shown favorable success.

  17. Plasma source ion implantation

    International Nuclear Information System (INIS)

    Conrad, J.R.; Forest, C.

    1986-01-01

    The authors' technique allows the ion implantation to be performed directly within the ion source at higher currents without ion beam extraction and transport. The potential benefits include greatly increased production rates (factors of 10-1000) and the ability to implant non-planar targets without rastering or shadowing. The technique eliminates the ion extractor grid set, beam raster equipment, drift space and target manipulator equipment. The target to be implanted is placed directly within the plasma source and is biased to a large negative potential so that plasma ions gain energy as they accelerate through the potential drop across the sheath that forms at the plasma boundary. Because the sheath surrounds the target on all sides, all surfaces of the target are implanted without the necessity to raster the beam or to rotate the target. The authors have succeeded in implanting nitrogen ions in a silicon target to the depths and concentrations required for surface treatment of materials like stainless steel and titanium alloys. They have performed ESCA measurements of the penetration depth profile of a silicon target that was biased to 30 kV in a nitrogen discharge plasma. Nitrogen ions were implanted to a depth of 700A at a peak concentration of 30% atomic. The measured profile is quite similar to a previously obtained profile in titanium targets with conventional techniques

  18. Influence of high intensity ultrasound with different probe diameter ...

    African Journals Online (AJOL)

    The main goal of this research is to analyze the influence of ultrasonic probe diameters (7 and 10 mm) of high-intensity ultrasound with constant frequency (30 kHz) on the degree of homogenization (variance) of cow milk. Influence of different probe diameters on the physical properties of cow milk was also tested. Changes ...

  19. Lumbar Vertebral Canal Diameters in Adult Ugandan Skeletons ...

    African Journals Online (AJOL)

    Background: Normal values of lumbar vertebral canal diameters are useful in facilitating diagnosis of lumbar vertebral canal stenosis. Various studies have established variation on values between different populations, gender, age, and ethnic groups. Objectives: To determine the lumbar vertebral canal diameters in adult ...

  20. Relationships between diameter and height of trees in natural ...

    African Journals Online (AJOL)

    Relationships between diameter and height of trees in natural tropical forest in Tanzania. Wilson A Mugasha, Ole M Bollandsås, Tron Eid. Abstract. The relationship between tree height (h) and tree diameter at breast height (dbh) is an important element describing forest stands. In addition, h often is a required variable in ...

  1. Heritability of optic disc diameters: a twin study

    DEFF Research Database (Denmark)

    Drobnjak, Dragana; Taarnhøj, Nina Charlotte; Mitchell, Paul

    2011-01-01

    , additive genetic factors (i.e. heritability) explained 77% (95% CI: 65-85%) of variation of vertical disc diameters, whereas estimated unshared environmental effect was 23% (95% CI: 15-35%). For vertical cup diameters, heritability accounted for 70% (95% CI: 55-80%) and environmental factors 30% (95% CI...

  2. Diameter of the thoracic and abdominal aorta in healthy Japanese

    International Nuclear Information System (INIS)

    Matsunaga, Wakako

    1989-01-01

    In 300 cases, diameter of thoracic and abdominal aorta in healthy Japanese is measured by computed tomography (CT) and the values are analyzed in relation to the age, sex and the level of the aorta on CT scan. Aorta becomes dilated with age. In female diameter of the aorta is correlated with age, on the other hand, diameter of those is not correlated with age in male. Diameter in male is larger than in female. Aorta tapers off and the ratio of tapering of the thoracic aorta is more prominent than that of the abdominal aorta. Therefore the calculations of the landmarks of tapering of the aorta and the ratio of diameter of the aorta to transverse diameter of the vertebral body at the levels of 10th thoracic and 3rd lumber vertebrae on CT scan are useful for judgement of normal range of diameter of the aorta. Calcifications of the wall of the aorta are seen initially at the age of 5th decade in the abdominal aorta and 6th decade in the thoracic aorta in healthy Japanese. They are noted in almost of the persons after the age of seventy years old. The presence of calcification is not correlated with diameter of the aorta at the same level on CT scan. (author)

  3. Generalized height-diameter models for Populus tremula L. stands

    African Journals Online (AJOL)

    USER

    2010-07-12

    Jul 12, 2010 ... and stand density) into the base height-diameter models increased the accuracy of prediction for P. tremula. .... parameter estimates compared with those obtained with ... using coefficient of determination for non-linear regression (. 2. R ), ..... stochastic height-diameter model for maritime pine ecoregions in.

  4. Sex Dimorphism of the Heart Diameters and Cardiothoracic Ratios ...

    African Journals Online (AJOL)

    Objective: To determine gender associated differences in the cardiothoracic ratio (CTR) and heart diameters in a normal Nigerian population. Subject and Method: The normal heart diameters and cardiothoracic ratios were measured from posteroanterior (PA) chest radiographs of healthy 510 male and 508 female ...

  5. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  6. Lysosome Transport as a Function of Lysosome Diameter

    Science.gov (United States)

    Bandyopadhyay, Debjyoti; Cyphersmith, Austin; Zapata, Jairo A.; Kim, Y. Joseph; Payne, Christine K.

    2014-01-01

    Lysosomes are membrane-bound organelles responsible for the transport and degradation of intracellular and extracellular cargo. The intracellular motion of lysosomes is both diffusive and active, mediated by motor proteins moving lysosomes along microtubules. We sought to determine how lysosome diameter influences lysosome transport. We used osmotic swelling to double the diameter of lysosomes, creating a population of enlarged lysosomes. This allowed us to directly examine the intracellular transport of the same organelle as a function of diameter. Lysosome transport was measured using live cell fluorescence microscopy and single particle tracking. We find, as expected, the diffusive component of intracellular transport is decreased proportional to the increased lysosome diameter. Active transport of the enlarged lysosomes is not affected by the increased lysosome diameter. PMID:24497985

  7. Structure and micro-mechanical properties of helium-implanted layer on Ti by plasma-based ion implantation

    International Nuclear Information System (INIS)

    Ma Xinxin; Li Jinlong; Sun Mingren

    2008-01-01

    The present paper concentrates on structure and micro-mechanical properties of the helium-implanted layer on titanium treated by plasma-based ion implantation with a pulsed voltage of -30 kV and doses of 3, 6, 9 and 12 x 10 17 ions/cm 2 , respectively. X-ray photoelectron spectroscopy and transmission electron microscopy are employed to characterize the structure of the implanted layer. The hardnesses at different depths of the layer were measured by nano-indentation. We found that helium ion implantation into titanium leads to the formation of bubbles with a diameter from a few to more than 10 nm and the bubble size increases with the increase of dose. The primary existing form of Ti is amorphous in the implanted layer. Helium implantation also enhances the ingress of O, C and N and stimulates the formations of TiO 2 , Ti 2 O 3 , TiO, TiC and TiN in the near surface layer. And the amount of the ingressed oxygen is obviously higher than those of nitrogen and carbon due to its higher activity. At the near surface layer, the hardnesses of all implanted samples increases remarkably comparing with untreated one and the maximum hardness has an increase by a factor of up to 3.7. For the samples implanted with higher doses of 6, 9 and 12 x 10 17 He/cm 2 , the local displacement bursts are clearly found in the load-displacement curves. For the samples implanted with a lower dose of 3 x 10 17 He/cm 2 , there is no obvious displacement burst found. Furthermore, the burst width increases with the increase of the dose

  8. Microstructures of group III-nitrides after implantation with gallium

    International Nuclear Information System (INIS)

    Kench, P.J.

    2001-05-01

    bubbles. A capping layer was used in an attempt to control the degradation of the implanted layer mechanically, but this was unsuccessful. The evidence from XPS and electron diffraction complemented one another and suggested that Ga-N bonds were in fact present. Thermal and laser anneals were performed in an attempt to lessen the bubble and precipitate damage caused by the implantation of Ga into InN, however no improvement in microstructure uniformity was observed. Gallium implantations into silicon nitride performed by S. A. Almieda (1998) were also studied using various microstructural characterisation techniques. It was found that the implanted Ga existed in a dispersion of colloids (5 nm in diameter). These colloids were found to be void of N, which is surprising since Ga-N bonds were detected by XPS in these specimens. It is proposed that either a low percentage of N remained undetected in the colloids allowing Ga-N bonds to form, or more likely that Ga-N bonds were present at the boundary formed between the Ga colloid and the a-SiN x layer. The microstructure of the layer appeared to be unaffected by the nitrogen concentration in the original a-SiN x layer. Annealing caused a broadening of the Ga colloid depth range and a reduction in the diameter of the colloids. Using CALPHAD, phase diagrams for the Ga-ln-N and Ga-AI-N alloy systems have been proposed. It has been shown that thermodynamic arguments can explain the observations of Al and In precipitation following Ga implantation into AIN and InN, respectively. The coalescence of Ga to form Ga clusters after implantation into a-SiN x is also explained using thermodynamic arguments. (author)

  9. Large diameter femoral heads impose significant alterations on the strains developed on femoral component and bone: a finite element analysis.

    Science.gov (United States)

    Theodorou, E G; Provatidis, C G; Babis, G C; Georgiou, C S; Megas, P D

    2011-01-01

    Total Hip Arthroplasty aims at fully recreating a functional hip joint. Over the past years modular implant systems have become common practice and are widely used, due to the surgical options they provide. In addition Big Femoral Heads have also been implemented in the process, providing more flexibility for the surgeon. The current study aims at investigating the effects that femoral heads of bigger diameter may impose on the mechanical behavior of the bone-implant assembly. Using data acquired by Computed Tomographies and a Coordinate Measurement Machine, a cadaveric femur and a Profemur-E modular stem were fully digitized, leading to a three dimensional finite element model in ANSYS Workbench. Strains and stresses were then calculated, focusing on areas of clinical interest, based on Gruen zones: the calcar and the corresponding below the greater trochanter area in the proximal femur, the stem tip region and a profile line along linea aspera. The performed finite elements analysis revealed that the use of large diameter heads produces significant changes in strain development within the bone volume, especially in the lateral side. The application of Frost's law in bone remodeling, validated the hypothesis that for all diameters normal bone growth occurs. However, in the calcar area lower strain values were recorded, when comparing with the reference model featuring a 28mm femoral head. Along line aspera and for the stem tip area, higher values were recorded. Finally, stresses calculated on the modular neck revealed increased values, but without reaching the yield strength of the titanium alloy used.

  10. Multilayer Photonic Crystal for Spectral Narrowing of Emission

    Directory of Open Access Journals (Sweden)

    Zhanfang LIU

    2017-08-01

    Full Text Available Multilayer colloidal crystal has been prepared by the layer-by-layer deposition of silica microspheres on a glass slide. Each layer is a slab consisting of a fcc close-packed colloidal arrays. By properly choosing the sizes of spheres, the whole spectral feature of multilayer colloidal crystal can be tuned. Here, we engineered a multilayer superlattice structure with an effective passband between two stop bands. This gives a strong narrowing effect on emission spectrum. With the stop bands at the shortwave and longwave edges of emission spectrum, the passband in the central wavelength region can be regarded as a strong decrease of suppression effect and enhancement of a narrow wavelength region of emission. The spectral narrowing modification effect of suitably engineered colloidal crystals shows up their importance in potential application as optical filters and lasing devices.DOI: http://dx.doi.org/10.5755/j01.ms.23.3.16320

  11. CT demonstration of pharyngeal narrowing in adult obstructive sleep apnea

    International Nuclear Information System (INIS)

    Bohlman, M.E.; Haponik, E.F.; Smith, P.L.; Allen, R.P.; Bleecker, E.R.; Goldman, S.M.

    1983-01-01

    Sleep apnea is a major cause of daytime hypersomnolence. Among the proposed etiologies, focal obstruction of the airways at the level of the pharynx has been suggested but not proven. Using computed tomography, the cross-sectional area of the airway can be readily assessed. Thirty-three adults with clinically proven sleep apnea and 12 normal adults underwent systematic computed tomography of the neck. Significant airway narrowing was demonstrated in all the patients with obstructive sleep apnea, whereas no such narrowing was seen in the controls. In 11, the narrowing was at a single level, whereas in 22 patients two or more levels were affected. This study has shown that a structurally abnormal airway may serve as an anatomic substrate for the development of sleep apnea. On the basis of this evidence, uvulopalatopharyngoplasty has been performed in two patients with relief of symptoms in one

  12. Pressure Fluctuation Characteristics of Narrow Gauge Train Running Through Tunnel

    Science.gov (United States)

    Suzuki, Masahiro; Sakuma, Yutaka

    Pressure fluctuations on the sides of narrow (1067 mm) gauge trains running in tunnels are measured for the first time to investigate the aerodynamic force acting on the trains. The present measurements are compared with earlier measurements obtained with the Shinkansen trains. The results are as follows: (1) The aerodynamic force, which stems from pressure fluctuations on the sides of cars, puts the energy into the vibration of the car body running through a tunnel. (2) While the pressure fluctuations appear only on one of the two sides of the trains running in double-track tunnels, the fluctuations in opposite phase on both sides in single-track tunnels. (3) The on-track test data of the narrow gauge trains show the same tendency as those of the Shinkansen trains, although it is suggested that the pressure fluctuations develop faster along the narrow gauge trains than the Shinkansen trains.

  13. MRI of surgically created pulmonary artery narrowing in the dog

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, R.J.; Rocchini, A.P.; Bove, E.L.; Chenevert, T.L.; Gubin, B. (Michigan Univ., Ann Arbor (USA). Dept. of Radiology)

    1989-11-01

    Narrowing of the pulmonary arteries was created surgically in twelve dogs. In six of the dogs the narrowing was central (main pulmonary artery), and in the remaining six the narrowing was located peripherally at the hilar level of the right pulmonary artery beyond the pericardial reflection. MRI and angiography were performed in all dogs. MRI clearly delineated the site of the pulmonary band and the caliber of the pulmonary artery at the site of the band in all dogs (N=6). MRI was not able to visualize any of the stenosis of the right pulmonary arteries at the hila, beyond the pericardial reflection. In addition, optimal imaging planes to depict each segment of the central pulmonary arteries were determined. The capability to image in oblique planes is essential in evaluating the morphology of the central pulmonary arteries. (orig.).

  14. MRI of surgically created pulmonary artery narrowing in the dog

    International Nuclear Information System (INIS)

    Hernandez, R.J.; Rocchini, A.P.; Bove, E.L.; Chenevert, T.L.; Gubin, B.

    1989-01-01

    Narrowing of the pulmonary arteries was created surgically in twelve dogs. In six of the dogs the narrowing was central (main pulmonary artery), and in the remaining six the narrowing was located peripherally at the hilar level of the right pulmonary artery beyond the pericardial reflection. MRI and angiography were performed in all dogs. MRI clearly delineated the site of the pulmonary band and the caliber of the pulmonary artery at the site of the band in all dogs (N=6). MRI was not able to visualize any of the stenosis of the right pulmonary arteries at the hila, beyond the pericardial reflection. In addition, optimal imaging planes to depict each segment of the central pulmonary arteries were determined. The capability to image in oblique planes is essential in evaluating the morphology of the central pulmonary arteries. (orig.)

  15. The Survival of Morse Cone-Connection Implants with Platform Switch.

    Science.gov (United States)

    Cassetta, Michele; Di Mambro, Alfonso; Giansanti, Matteo; Brandetti, Giulia

    2016-01-01

    The aim of this prospective clinical study was to evaluate the survival up to 5 years of Morse cone-connection implants with platform switch considering the influence of biologically relevant, anatomical, and stress-related variables. STROBE guidelines were followed. Seven hundred forty-eight implants were inserted in 350 patients. Follow-up visits were scheduled at the time of stagetwo surgery (2 months later) and at 6, 12, 24, 36, and 60 months. All implants were initially loaded with a cemented provisional acrylic restoration. The definitive metal-ceramic restorations were cemented at the 6-month follow-up. Implant cumulative survival rates (CSRs) were calculated using life table actuarial method. Survival data were also analyzed by the log-rank test and Cox regression. The statistical analysis was conducted at the patient level. P ≤ .05 was considered as an indicator of statistical significance. During the follow-up (mean: 40 months; SD: 20.27), 28 patients were considered failed (8%). The CSR and its standard error (SE) was 92% ± 2.17%. Patients with implant-supported single crowns had a CSR of 90%, whereas those with implant-supported fixed dental prostheses had a CSR of 93%. The implant diameter (P = .0399) and implant length (P = .0441) were statistically significant. The probability of failure was almost 75% lower for patients with wide rather than standard implants, 91% lower for patients with long implants, and 69% lower for patients with standard implants compared with short implants. The use of Morse cone-connection implants with platform switch is a safe and reliable treatment method. Stress-related variables influence the risk of failure confirming the importance of biomechanical factors in the longevity of osseointegrated implants; thus, the clinician may obtain better results if attention is paid to these factors.

  16. Alveolar Bone Resorption Evaluation Around Single-piece Designed Bicortical Implants, Using Immediate Loading Protocol, Based on Orthopantomographs

    Directory of Open Access Journals (Sweden)

    Száva Dániel-Tamás

    2017-12-01

    Full Text Available Background: Inserting dental implants in severely atrophied jawbones is a great challenge for the dental practitioner. There are an increasing number of patients who choose dental implantanchored prosthetic restorations despite compromised bone quality and quantity. There have been numerous attempts in adapting implant design for the atrophic crestal bone. One-piece, needle-type basal implant design is a typical design for these cases. These implants are inserted in the remaining compact bone located in the basal aspect of the jawbones. If high primary stability is achieved, these implants are used for immediate loading protocol. From many points of view, this technique is based on contradictory principles compared to classic implant surgery and loading protocols. The aim of this study was to investigate the long-term success of basal one-piece short-diameter dental implants used for immediate loading protocol.

  17. Interaction of implanted deuterium and helium with beryllium: radiation enhanced oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Langley, R.A.

    1979-01-01

    The interaction of implanted deuterium and helium with beryllium is of significant interest in the application of first wall coatings and other components of fusion reactors. Electropolished polycrystalline beryllium was first implanted with an Xe backscatter marker at 1.98 MeV followed by either implantation with 5 keV diatomic deuterium or helium. A 2.0 MeV He beam was used to analyze for impurity buildup; namely oxygen. The oxide layer thickness was found to increase linearly with increasing implant fluence. A 2.5 MeV H/sup +/ beam was used to depth profile the D and He by ion backscattering. In addition the retention of the implant was measured as a function of the implant fluence. The mean depth of the implant was found to agree with theoretical range calculations. Scanning electron microscopy was used to observe blister formation. No blisters were observed for implanted D but for implanted He blisters occurred at approx. 1.75 x 10/sup 17/ He cm/sup -2/. The blister diameter increased with increasing implant fluence from about 0.8 ..mu..m at 10/sup 18/ He cm/sup -2/ to 5.5 ..mu..m at 3 x 10/sup 18/ He cm/sup -2/.

  18. Interaction of implanted deuterium and helium with beryllium: radiation enhanced oxidation

    International Nuclear Information System (INIS)

    Langley, R.A.

    1979-01-01

    The interaction of implanted deuterium and helium with beryllium is of significant interest in the application of first wall coatings and other components of fusion reactors. Electropolished polycrystalline beryllium was first implanted with an Xe backscatter marker at 1.98 MeV followed by either implantation with 5 keV diatomic deuterium or helium. A 2.0 MeV He beam was used to analyze for impurity buildup; namely oxygen. The oxide layer thickness was found to increase linearly with increasing implant fluence. A 2.5 MeV H + beam was used to depth profile the D and He by ion backscattering. In addition the retention of the implant was measured as a function of the implant fluence. The mean depth of the implant was found to agree with theoretical range calculations. Scanning electron microscopy was used to observe blister formation. No blisters were observed for implanted D but for implanted He blisters occurred at approx. 1.75 x 10 17 He cm -2 . The blister diameter increased with increasing implant fluence from about 0.8 μm at 10 18 He cm -2 to 5.5 μm at 3 x 10 18 He cm -2

  19. USE OF NARROW-DIAMETER DIRECT-PUSH WELLS TO CHARACTERIZE AND REMEDIATE CARBON TETRACHLORIDE IN THE 200 WEST AREA HANFORD SITE, WASHINGTON

    International Nuclear Information System (INIS)

    Rohay, V.J.

    2009-01-01

    This single page graphic shows several figures. The Hydraulic Hammer Rig (HHR) direct-push technology has been successfully used to characterize carbon tetrachloride in the vadose zone. Based on their favorable performance and radius of influence, HHR SVE wells have potential for future use in both monitoring and targeted SVE to achieve VOC cleanup goals at the carbon tetrachloride waste sites

  20. Steroid therapy and conduction disturbances after transcatheter aortic valve implantation.

    Science.gov (United States)

    Havakuk, Ofer; Konigstein, Maayan; Ben Assa, Eyal; Arbel, Yaron; Abramowitz, Yigal; Halkin, Amir; Bazan, Samuel; Shmilovich, Haim; Keren, Gad; Finkelstein, Ariel; Banai, Shmuel

    2016-10-01

    Direct mechanical compression of the frame struts on the adjacent bundle branch with local inflammatory reaction might cause conduction system disturbances and need for pacemaker implantation following transcatheter aortic valve implantation (TAVI). We assessed the impact of preprocedural anti-inflammatory steroid therapy on the occurrence of conduction disturbances following TAVI. From a cohort of 324 patients who underwent transfemoral TAVI, 39 (12%) were pretreated with steroids because of iodine allergy (n=29) or active obstructive pulmonary disease (n=10). We compared the rate of occurrence of new conduction disturbances and pacemaker implantation between TAVI patients with (n=39) and without (n=285) steroid treatment, using Cox logistic regression estimates and proportional hazards models. The overall occurrence of new conduction defects and the need for new pacemaker implantation were similar among steroid and non-steroid-treated patients (38.4% vs 37.5% and 25.6% vs 25.3%, respectively). New conduction disturbances were more prevalent in patients treated with CoreValve prosthesis, low implantation, and smaller aortic annulus diameter (P<.001, P<.001, and P=.006, respectively). Thirty-day mortality and complication rates were similar between the groups. Although safe, steroid treatment prior to TAVI failed to reduce the incidence of new conduction defects and the need for pacemaker implantation. © 2016 John Wiley & Sons Ltd.

  1. Electromechanical impedance method to assess dental implant stability

    International Nuclear Information System (INIS)

    Tabrizi, Aydin; Rizzo, Piervincenzo; Ochs, Mark W

    2012-01-01

    The stability of a dental implant is a prerequisite for supporting a load-bearing prosthesis and establishment of a functional bone–implant system. Reliable and noninvasive methods able to assess the bone interface of dental and orthopedic implants (osseointegration) are increasingly demanded for clinical diagnosis and direct prognosis. In this paper, we propose the electromechanical impedance method as a novel approach for the assessment of dental implant stability. Nobel Biocare ® implants with a size of 4.3 mm diameter ×13 mm length were placed inside bovine bones that were then immersed in a solution of nitric acid to allow material degradation. The degradation simulated the inverse process of bone healing. The implant–bone systems were monitored by bonding a piezoceramic transducer (PZT) to the implants’ abutment and measuring the admittance of the PZT over time. It was found that the PZT’s admittance and the statistical features associated with its analysis are sensitive to the degradation of the bones and can be correlated to the loss of calcium measured by means of the atomic absorption spectroscopy method. The present study shows promising results and may pave the road towards an innovative approach for the noninvasive monitoring of dental implant stability and integrity. (paper)

  2. COMPLEX OPTICAL CHARACTERIZATION OF MESH IMPLANTS AND ENCAPSULATION AREA

    Directory of Open Access Journals (Sweden)

    VALERIY P. ZAKHAROV

    2013-04-01

    Full Text Available Complex investigation of mesh implants was performed involving laser confocal microscopy, backscattered probing and OCT imaging methods. The growth of endomysium and fat tissue with microcirculation vessels was observed in the mesh encapsulation region. Confocal microscopy analysis shows that such pathologies complications such as necrosis formation and microcavities were localized in the area near implant fibers with the size compatible with fiber diameter. And the number of such formations increase with the increase of the size, number and density of microdefects on the implant surface. Results of numerical simulations show that it is possible to control implant installation up to the depth to 4 mm with a help of backscattering probing. The applicability of OCT imaging for mesh implant control was demonstrated. Special two-stage OCT image noise-reduction algorithm, including empirical mode decomposition, was proposed for contrast increase and better abnormalities visualization by halving the signal-to-noise ratio. Joint usage of backscattered probing and OCT allows to accurately ascertain implant and surrounding tissue conditions, which reduces the risk of relapse probability.

  3. Narrow-width mechanism of a=5 Ξ-state

    International Nuclear Information System (INIS)

    Kumagai-Fuse, I.; Akaishi, Y.

    1995-04-01

    Narrow-width mechanism of ≡ 5 H is discussed by calculating conversion widths to all its possible decay channels. Since the conversion processes have small reaction Q values, the three- and four- body decays are strongly suppressed owing to small phase volumes available. Decay widths to the two-body channels are significantly reduced by the distortion of emitted-particle waves. This mechanism brings about a narrow width of ≡ 5 H. The total width is estimated to be 0.87 MeV, in which the largest contribution comes from the decay into the Λ 4 H * +Λ channel. (author)

  4. Effects of Diameter on Initial Stiffness of P-Y Curves for Large-Diameter Piles in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo; Augustesen, Anders Hust

    2010-01-01

    is developed for slender piles with diameters up to approximately 2.0 m. Hence, the method is not validated for piles with diameters of 4–6 m. The aim of the paper is to extend the p-y curve method to large-diameter non-slender piles in sand by considering the effects of the pile diameter on the soil-pile...... interaction. Hence, a modified expression for the p-y curves for statically loaded piles in sand is proposed in which the initial slope of the p-y curves depends on the depth below the soil surface, the pile diameter and the internal angle of friction. The evaluation is based on three-dimensional numerical...... analyses by means of the commercial program FLAC3D incorporating a Mohr-Coulomb failure criterion. The numerical model is validated with laboratory tests in a pressure tank at Aalborg University....

  5. Critical heat flux of subcooled flow boiling in a narrow tube

    International Nuclear Information System (INIS)

    Inasaka, Fujio; Nariai, Hideki; Shimura, Toshiya.

    1986-01-01

    The critical heat flux (CHF) of subcooled flow boiling in a narrow tube was investigated experimentally using water as a coolant. Experiments were conducted at nearly ambient pressure under the following conditions: tube inside diameter: 1 ∼ 3 mm, tube length: 10 ∼ 100 mm, and water mass velocity: 7000 - 20000 kg/(m 2 · s). The critical heat flux increases the shorter the tube length and the smaller the tube inside diameter, at the same water mass velocity and exit quality. Experimental data were compared with empirical correlations, such as the Griffel and Knoebel correlations for subcooled boiling at low pressure, the Tong correlation for subcooled boiling at high pressure, and the Katto correlation. The existence of two parameter regions was confirmed. The first is the low CHF region in which experimental data can be predicted well by Griffel and Knoebel correlations, and the second is the high CHF region in which experimental data are higher than the predictions by the above two correlations. (author)

  6. Diameter dependent electron transfer kinetics in semiconductor-enzyme complexes.

    Science.gov (United States)

    Brown, Katherine A; Song, Qing; Mulder, David W; King, Paul W

    2014-10-28

    Excited state electron transfer (ET) is a fundamental step for the catalytic conversion of solar energy into chemical energy. To understand the properties controlling ET between photoexcited nanoparticles and catalysts, the ET kinetics were measured for solution-phase complexes of CdTe quantum dots and Clostridium acetobutylicum [FeFe]-hydrogenase I (CaI) using time-resolved photoluminescence spectroscopy. Over a 2.0-3.5 nm diameter range of CdTe nanoparticles, the observed ET rate (kET) was sensitive to CaI concentration. To account for diameter effects on CaI binding, a Langmuir isotherm and two geometric binding models were created to estimate maximal CaI affinities and coverages at saturating concentrations. Normalizing the ET kinetics to CaI surface coverage for each CdTe diameter led to k(ET) values that were insensitive to diameter, despite a decrease in the free energy for photoexcited ET (ΔGET) with increasing diameter. The turnover frequency (TOF) of CaI in CdTe-CaI complexes was measured at several molar ratios. Normalization for diameter-dependent changes in CaI coverage showed an increase in TOF with diameter. These results suggest that k(ET) and H2 production for CdTe-CaI complexes are not strictly controlled by ΔG(ET) and that other factors must be considered.

  7. Study on Soap-free P(MMA-EA-AA/MAA) Latex Particles With Narrow Size Distribution

    Institute of Scientific and Technical Information of China (English)

    K. Kang; C. Y. Kan; Y. Du; D. S. Liu

    2005-01-01

    @@ 1Introduction In the past decades, more and more studies have been focused on the synthesis of monodisperse particles with different diameter by special polymerization technique. In 1980' s, Ugelstad, et al[1] invented two-step swelling method to prepare monodisperse microsphere with large size more than 1 μm. In the following decade, Okubo and his coworkers[2] synthesized monodisperse crosslinked polymer particles above 3 μm using one-step dynamic swelling method. New method has been developed to produce particles more than 50 μm in diameter with a standard deviation of less than 2%[3]. Up to now, most of the monodisperse particles were usually prepared by polymerization of St in the presence of surfactants. In this presentation, sub-micro sized P (MMA-EA-AA/MAA) particles with narrow size distribution were prepared by seeded emulsion polymerization in the absence of any surfactant materials.

  8. The prevalence of cervical myelopathy among subjects with narrow cervical spinal canal in a population-based magnetic resonance imaging study: the Wakayama Spine Study.

    Science.gov (United States)

    Nagata, Keiji; Yoshimura, Noriko; Hashizume, Hiroshi; Muraki, Shigeyuki; Ishimoto, Yuyu; Yamada, Hiroshi; Takiguchi, Noboru; Nakagawa, Yukihiro; Minamide, Akihito; Oka, Hiroyuki; Kawaguchi, Hiroshi; Nakamura, Kozo; Akune, Toru; Yoshida, Munehito

    2014-12-01

    A narrow cervical spinal canal (CSC) is a well-known risk factor for cervical myelopathy (CM). However, no epidemiologic data of the CSC based on a population-based cohort are available. The purpose of the study was to investigate the age-related differences in CSC diameters on plain radiographs and to examine the associated magnetic resonance imaging (MRI) abnormalities including cervical cord compression and increased signal intensity (ISI) as well as the clinical CM with the narrow CSC. This was a cross-sectional study. Data were obtained from the baseline survey of the Wakayama Spine Study that was performed from 2008 to 2010 in a western part of Japan. Finally, a total of 959 subjects (319 men and 640 women; mean age, 66.4 years) were included. The outcome measures included in the study were the CSC diameter at C5 level on plain radiographs, cervical cord compression and ISI on sagittal T2-weighted MRI, and physical signs related to CM (eg, the Hoffmann reflex, hyperreflexia of the patellar tendon, the Babinski reflex, sensory and motor function, and bowel/bladder symptoms). The age-related differences of CSC diameters in men and women were investigated by descriptive statistics. The prevalence of MRI abnormalities and clinical CM was compared among the groups divided by the CSC diameter (less than 13, 13-15, and 15 mm or more). In addition, a logistic regression analysis was performed to determine the association of the CSC diameter with cervical cord compression/clinical CM after overall adjustment for age, sex, and body mass index. The CSC diameter was narrower with increasing age in both men and women. The prevalence of cervical cord compression, ISI, and the clinical CM was significantly higher in the narrower CSC group. The prevalence of cervical cord compression, ISI, and CM among subjects with CSC diameter less than 13 mm was 38.0%, 5.4%, and 10.1%, respectively. In the logistic model, the CSC diameter was a significant predictive factor for the

  9. Brain Arterial Diameters as a Risk Factor for Vascular Events.

    Science.gov (United States)

    Gutierrez, Jose; Cheung, Ken; Bagci, Ahmet; Rundek, Tatjana; Alperin, Noam; Sacco, Ralph L; Wright, Clinton B; Elkind, Mitchell S V

    2015-08-06

    Arterial luminal diameters are routinely used to assess for vascular disease. Although small diameters are typically considered pathological, arterial dilatation has also been associated with disease. We hypothesize that extreme arterial diameters are biomarkers of the risk of vascular events. Participants in the Northern Manhattan Study who had a time-of-flight magnetic resonance angiography were included in this analysis (N=1034). A global arterial Z-score, called the brain arterial remodeling (BAR) score, was obtained by averaging the measured diameters within each individual. Individuals with a BAR score -2 and 2 SDs had the largest diameters. All vascular events were recorded prospectively after the brain magnetic resonance imaging. Spline curves and incidence rates were used to test our hypothesis. The association of the BAR score with death (P=0.001), vascular death (P=0.02), any vascular event (P=0.05), and myocardial infarction (P=0.10) was U-shaped except for ischemic stroke (P=0.74). Consequently, incidence rates for death, vascular death, myocardial infarction, and any vascular event were higher in individuals with the largest diameters, whereas individuals with the smallest diameters had a higher incidence of death, vascular death, any vascular event, and ischemic stroke compared with individuals with average diameters. The risk of death, vascular death, and any vascular event increased at both extremes of brain arterial diameters. The pathophysiology linking brain arterial remodeling to systemic vascular events needs further research. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  10. Inferring diameters of spheres and cylinders using interstitial water.

    Science.gov (United States)

    Herrera, Sheryl L; Mercredi, Morgan E; Buist, Richard; Martin, Melanie

    2018-06-04

    Most early methods to infer axon diameter distributions using magnetic resonance imaging (MRI) used single diffusion encoding sequences such as pulsed gradient spin echo (SE) and are thus sensitive to axons of diameters > 5 μm. We previously simulated oscillating gradient (OG) SE sequences for diffusion spectroscopy to study smaller axons including the majority constituting cortical connections. That study suggested the model of constant extra-axonal diffusion breaks down at OG accessible frequencies. In this study we present data from phantoms to test a time-varying interstitial apparent diffusion coefficient. Diffusion spectra were measured in four samples from water packed around beads of diameters 3, 6 and 10 μm; and 151 μm diameter tubes. Surface-to-volume ratios, and diameters were inferred. The bead pore radii estimates were 0.60±0.08 μm, 0.54±0.06 μm and 1.0±0.1 μm corresponding to bead diameters ranging from 2.9±0.4 μm to 5.3±0.7 μm, 2.6±0.3 μm to 4.8±0.6 μm, and 4.9±0.7 μm to 9±1 μm. The tube surface-to-volume ratio estimate was 0.06±0.02 μm -1 corresponding to a tube diameter of 180±70 μm. Interstitial models with OG inferred 3-10 μm bead diameters from 0.54±0.06 μm to 1.0±0.1 μm pore radii and 151 μm tube diameters from 0.06±0.02 μm -1 surface-to-volume ratios.

  11. Diameter dependent failure current density of gold nanowires

    International Nuclear Information System (INIS)

    Karim, S; Maaz, K; Ali, G; Ensinger, W

    2009-01-01

    Failure current density of single gold nanowires is investigated in this paper. Single wires with diameters ranging from 80 to 720 nm and length 30 μm were electrochemically deposited in ion track-etched single-pore polycarbonate membranes. The maximum current density was investigated while keeping the wires embedded in the polymer matrix and ramping up the current until failure occurred. The current density is found to increase with diminishing diameter and the wires with a diameter of 80 nm withstand 1.2 x 10 12 A m -2 before undergoing failure. Possible reasons for these results are discussed in this paper.

  12. Reduced arterial diameter during static exercise in humans

    DEFF Research Database (Denmark)

    Olesen, H L; Mitchell, J H; Friedman, D B

    1995-01-01

    In eight subjects luminal diameter of the resting limb radial and dorsalis pedis arteries was determined by high-resolution ultrasound (20 MHz). This measurement was followed during rest and during 2 min of static handgrip or of one-leg knee extension at 30% of maximal voluntary contraction...... exertion was approximately 15 units after both types of exercise. The dorsalis pedis arterial diameter was 1.50 +/- 0.20 mm (mean and SE) and the radial AD 2.45 +/- 0.12 mm. During both types of contractions the luminal diameters decreased approximately 3.5% within the first 30 s (P

  13. Laser direct writing using submicron-diameter fibers.

    Science.gov (United States)

    Tian, Feng; Yang, Guoguang; Bai, Jian; Xu, Jianfeng; Hou, Changlun; Liang, Yiyong; Wang, Kaiwei

    2009-10-26

    In this paper, a novel direct writing technique using submicron-diameter fibers is presented. The submicron-diameter fiber probe serves as a tightly confined point source and it adopts micro touch mode in the process of writing. The energy distribution of direct writing model is analyzed by Three-Dimension Finite-Difference Time-Domain method. Experiments demonstrate that submicron-diameter fiber direct writing has some advantages: simple process, 350-nm-resolution (lower than 442-nm-wavelength), large writing area, and controllable width of lines. In addition, by altering writing direction of lines, complex submicron patterns can be fabricated.

  14. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  15. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...

  16. Adapted preparation technique for screw-type implants: explorative in vitro pilot study in a porcine bone model.

    Science.gov (United States)

    Beer, Andreas; Gahleitner, André; Holm, Anders; Birkfellner, Wolfgang; Homolka, Peter

    2007-02-01

    The aim of this study was to quantify the effect of adapted preparation on the insertion torque of self-tapping implants in cancellous bone. In adapted preparation, bone condensation - and thus, insertion torque - is controlled by changing the diameter of the drilling. After preparation of cancellous porcine vertebral bone with drills of 2.85, 3, 3.15 or 3.35 mm final diameters, Brånemark sytem Mk III implants (3.75 x 11.5 mm) were inserted in 141 sites. During implantation, the insertion torque was recorded. Prior to implant insertion, bone mineralization (bone mineral density (BMD)) was measured with dental quantative computed tomography. The BMD values measured at the implant position were correlated with insertion torque for varying bone condensation. Based on the average torque recorded during implant insertion into the pre-drilled canals with a diameter of 3 mm, torque increased by approximately 17% on reducing the diameter of the drill by 5% (to 2.85 mm). On increasing the diameter of the osteotomy to 3.15 mm (5%) or 3.35 mm (12%), torque values decreased by approximately 21% and 50%, respectively. The results demonstrate a correlation between primary stability (average insertion torque) and the diameter of the implant bed on using a screw-shaped implant. Thus, using an individualized bone mineralization-dependent drilling technique, optimized torque values could be achieved in all tested bone qualities with BMDs ranging from 330 to 500 mg/cm(3). The results indicate that using a bone-dependent drilling technique, higher torque values can also be achieved in poor bone using an individualized drilling resulting in higher bone condensation. As immediate function is dependent on primary stability (high insertion torque), this indicates that primary stability can be increased using a modified drilling technique in lesser mineralized bone.

  17. The scala vestibuli for cochlear implantation. An anatomic study.

    Science.gov (United States)

    Gulya, A J; Steenerson, R L

    1996-02-01

    Traditionally, cochlear implantation has used the scala tympani (ST) for electrode insertion. When faced with ST ossification, the surgeon may elect to drill out the cochlea to accomplish partial electrode insertion. Theoretically, another option in this situation is to insert the electrode into the scala vestibuli (SV). To determine whether or not the dimensions of the SV are sufficient to accommodate an electrode array so as to assess the feasibility of SV cochlear implantation. The study of 20 normal human temporal bones, comparing the maximum diameter and surface area of the ST with those of the combined SV and scala media. The dimensions of the SV and scala media were comparable to those of the ST and appeared sufficient to accommodate a cochlear implant electrode array. It appears that the combination of SV and scala media is a viable alternative route for electrode insertion, at least on the basis of anatomic dimensions, in those cases in which the ST is obliterated.

  18. Bone compaction enhances implant fixation in a canine gap model

    DEFF Research Database (Denmark)

    Kold, Søren; Rahbek, Ole; Toft, Marianne

    2005-01-01

    A new bone preparation technique, compaction, has increased fixation of implants inserted with exact-fit or press-fit to bone. Furthermore, a demonstrated spring-back effect of compacted bone might be of potential value in reducing the initial gaps that often exist between clinical inserted...... implants and bone. However, it is unknown whether the compression and breakage of trabeculae during the compaction procedure results in impaired gap-healing of compacted bone. Therefore, we compared compaction with conventional drilling in a canine gap model. Grit-blasted titanium implants (diameter 6 mm...... that the beneficial effect of reduced gap size, as compacted bone springs back, is not eliminated by an impaired gap-healing of compacted bone....

  19. The Argument for a Narrow Conception of 'Religious Autonomy'

    DEFF Research Database (Denmark)

    Christoffersen, Lisbet

    2015-01-01

    This article argues for a both horizontal and vertical narrow concept of collective freedom of Religion. The most recent ECtHR judgments as well as the US Supreme Court Hosanna-Tabor case leads theory to establish religious autonomy based on parallel legal roders. Nordic theory has been based...

  20. Predicting soil nitrogen content using narrow-band indices from ...

    African Journals Online (AJOL)

    Optimal fertiliser applications for sustainable forest stand productivity management, whilst protecting the environment, is vital. This study estimated soil nitrogen content using leaf-level narrow-band vegetation indices derived from a hand-held 350–2 500 nm spectroradiometer. Leaf-level spectral data were collected and ...

  1. Nonstationary Narrow-Band Response and First-Passage Probability

    DEFF Research Database (Denmark)

    Krenk, Steen

    1979-01-01

    The notion of a nonstationary narrow-band stochastic process is introduced without reference to a frequency spectrum, and the joint distribution function of two consecutive maxima is approximated by use of an envelope. Based on these definitions the first passage problem is treated as a Markov po...

  2. Free-Molecular Gas Flow in Narrow (Nanoscale) Channel

    Czech Academy of Sciences Publication Activity Database

    Levdansky, V.V.; Roldugin, V.I.; Žďanov, V.M.; Ždímal, Vladimír

    2014-01-01

    Roč. 87, č. 4 (2014), s. 802-814 ISSN 1062-0125 Grant - others:BRFFI(BY) T12P-018; RFBR(RU) 12-08-90009 Institutional support: RVO:67985858 Keywords : narrow channels * free-molecular gas flow * surface diffusion Subject RIV: CF - Physical ; Theoretical Chemistry

  3. Experimental Study on Critical Power in a Hemispherical Narrow Gap

    International Nuclear Information System (INIS)

    Park, Rae-Joon; Ha, Kwang-Soon; Kim, Sang-Baik; Kim, Hee-Dong; Jeong, Ji-Hwan

    2002-01-01

    An experimental study of critical heat flux in gap (CHFG) has been performed to investigate the inherent cooling mechanism in a hemispherical narrow gap. The objectives of the CHFG test are to measure critical power from a critical heat removal rate through the hemispherical narrow gap using distilled water with experimental parameters of system pressure and gap width. The CHFG test results have shown that a countercurrent flow limitation (CCFL) brings about local dryout at the small edge region of the upper part and finally global dryout in a hemispherical narrow gap. Increases in the gap width and pressure lead to an increase in critical power. The measured values of critical power are lower than the predictions made by other empirical CHF correlations applicable to flat plate, annuli, and small spherical gaps. The measured data on critical power in the hemispherical narrow gaps have been correlated using nondimensional parameters with a range of approximately ±20%. The developed correlation has been expanded to apply the spherical geometry using the Siemens/KWU correlation

  4. Career Attainment among Healthcare Executives: Is the Gender Gap Narrowing?

    Science.gov (United States)

    Branin, Joan Julia

    2009-01-01

    Health care occupations are expected to be among the fastest growing professions in the next ten years. With such incredible growth expected in employment and wages, and with women's participation in the industry remaining strong, are women in the health care industry, particularly those in health care administration, experiencing a narrowing of…

  5. Narrow-Band Imaging: Clinical Application in Gastrointestinal Endoscopy

    Directory of Open Access Journals (Sweden)

    Sandra Barbeiro

    2018-03-01

    Full Text Available Narrow-band imaging is an advanced imaging system that applies optic digital methods to enhance endoscopic images and improves visualization of the mucosal surface architecture and microvascular pattern. Narrow-band imaging use has been suggested to be an important adjunctive tool to white-light endoscopy to improve the detection of lesions in the digestive tract. Importantly, it also allows the distinction between benign and malignant lesions, targeting biopsies, prediction of the risk of invasive cancer, delimitation of resection margins, and identification of residual neoplasia in a scar. Thus, in expert hands it is a useful tool that enables the physician to decide on the best treatment (endoscopic or surgical and management. Current evidence suggests that it should be used routinely for patients at increased risk for digestive neoplastic lesions and could become the standard of care in the near future, at least in referral centers. However, adequate training programs to promote the implementation of narrow-band imaging in daily clinical practice are needed. In this review, we summarize the current scientific evidence on the clinical usefulness of narrow-band imaging in the diagnosis and characterization of digestive tract lesions/cancers and describe the available classification systems.

  6. Note: Folded optical system for narrow forward looking probe

    International Nuclear Information System (INIS)

    Hou, Hsuan-Chao; Hah, Dooyoung; Kim, Jeonghwan; Feldman, M.

    2014-01-01

    An optical system is described in which a laser beam makes three passes through a single graded index lens, forming a focus along the optic axis. It has important applications in endoscopic probes, where the forward looking characteristic permits the avoidance of obstacles and the narrow structure makes it minimally invasive

  7. Modeling of air flow through a narrow crack

    International Nuclear Information System (INIS)

    Trojek, T.; Cechak, T.; Moucka, L.; Fronka, A.

    2004-01-01

    Radon transport in dwellings is governed to a significant extent by pressure differences and properties of transport pathways. A model of air flow through narrow cracks was created in order to facilitate prediction of air velocity and air flow. Theoretical calculations, based on numerical solution of a system of differential equations, were compared with measurements carried out on a window crack. (P.A.)

  8. Measurements of Narrow Mg II Associated Absorption Doublets with ...

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... The measurement of the variations of absorption lines over time is a good method to study the physical conditions of absorbers. In this paper, we measure the variations of the line strength of 36 narrow Mg II2796, 2803 associated absorption doublets, which are imprinted on 31 quasar spectra with two ...

  9. Japanese VLBI Network Observations of a Gamma-Ray Narrow ...

    Indian Academy of Sciences (India)

    J. Astrophys. Astr. (2014) 35, 215–218 c Indian Academy of Sciences. Japanese VLBI Network Observations of a Gamma-Ray. Narrow-Line Seyfert 1 Galaxy 1H 0323+342. Kiyoaki Wajima1,∗. , Kenta Fujisawa2, Masaaki Hayashida3. & Naoki Isobe4. 1Shanghai Astronomical Observatory, Chinese Academy of Sciences,.

  10. Extrinsic stretching narrowing and anterior indentation of the rectosigmoid junction

    International Nuclear Information System (INIS)

    Schulman, A.; Fataar, S.

    1979-01-01

    Thirty-five cases of extrinsic narrowing or anterior indentation of the rectosigmoid junction (RSJ) have been studied. The RSJ lies directly behind the pouch of Douglas which is a favoured site for peritoneal metastasis, abscess and endometriosis. Any space-occupying lesion of sufficient size at this site will indent the anterior aspects of the RSJ. Causes include distension or tumour of the ileum or sigmoid colon, gross ascites (when the patient is erect), and tumours below the pelvic peritonium, such as gynaecological neoplasm and internal iliac artery aneurysm. When a desmoplastic metastasis in the pouch of Douglas infiltrates the outer layers of the RSJ, the fibrosis produces an eccentric shortening on its anterior aspect, which in turn causes a pleating of the mucosa with the folds radiating towards the shortened area. This is also seen with primary pelvic carcinomas directly adherent to the rectum, endometriosis with repeated bleeding and increasing eccentric, submucosal fibrosis, and chronic abscess in the pouch of Douglas. Not all extrinsic narrowing of the RSJ are pathological. One case of anterior indentation followed operation for rectal prolapse. Ten additional cases showed narrowing due to a technical artefact air-distended colon rising into the upper abdomen to cause stretching at the RSJ. As with ascites, this narrowing due to 'high-rise sigmoid' disappeared when the patients became recumbent and the colonic air redistributed. (author)

  11. Narrow coherent effects in πNN-dynamics

    International Nuclear Information System (INIS)

    Kudryavtsev, A.E.; Obrant, G.Z.

    1990-01-01

    Coherent effect production is considered in πNN-dynamics with resonant pion-nucleon interaction via Brueckner theory and Faddev equations. It is shown that the narrow energy and final momentum dependence can arise in the inelastic S-wave πd-scattering. The energy dependence peculiarities can have a width an order magnitude less than πN-resonance one

  12. A "Narrowing of Inquiry" in American Moral Psychology and Education

    Science.gov (United States)

    Richardson, Michael J.; Slife, Brent D.

    2013-01-01

    We explore the possibility that a priori philosophical commitments continue to result in a narrowing of inquiry in moral psychology and education where theistic worldviews are concerned. Drawing from the theories of Edward L. Thorndike and John Dewey, we examine naturalistic philosophical commitments that influenced the study of moral psychology…

  13. Management of peri-implantitis

    Directory of Open Access Journals (Sweden)

    Jayachandran Prathapachandran

    2012-01-01

    Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.

  14. Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures.

    Science.gov (United States)

    Shim, Hye Won; Yang, Byoung-Eun

    2015-12-01

    To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth Ankylos® implants. This was a retrospective clinical study that analyzed 450 single Ankylos® implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all Pabutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.

  15. Polyhydroxybutyrate/valerate/polycaprolactone small-diameter vascular graft: Experimental study of integration into organism

    Energy Technology Data Exchange (ETDEWEB)

    Antonova, L. V., E-mail: antonova.la@mail.ru; Burago, A. Yu.; Matveeva, V. G.; Velikanova, E. A.; Mukhamadiyarov, R. A.; Glushkova, T. V.; Kudryavtseva, Y. A.; Barbarash, O. L.; Barbarash, L. S. [Research Institute for Complex Issues of Cardiovascular Diseases, Kemerovo (Russian Federation); Mironov, A. V. [Kemerovo Cardiology Dispensary, Kemerovo (Russian Federation)

    2015-10-27

    We prepared polyhydroxybutyrate/valerate (PHBV)/polylcaprolactone (PCL) small-diameter vascular grafts using electrospinning. Surface structure was assessed by scanning electron microscopy whilst physicomechanical properties were investigated by longitudinal uniaxial tension testing. Patency of grafts implanted into the rat abdominal aorta was evaluated using a Doppler ultrasonography at 2 week, 1 month and 12 month postimplantation. In addition, we assessed local histological features, along with IL-1β, IL-2, IL-4, IL-10, TNFa, TGF-β1, and VEGF serum levels. We revealed that only 2 (25%) grafts were not thrombosed at 2 week and 1 month postimplantation. However, at 12 month postimplantation a satisfactory histological pattern was observed in 50% of all cases, and we detected a monolayer of endothelial cells on the inner graft surface in half the cases. Regarding other grafts, we revealed minor connective tissue hyperplasia in 41.7% of the grafts and an inflammatory infiltrate in the part of the arterial wall in 8.3% of the grafts. We found that the IL-1β serum level was 3.5-fold higher in the group of experimental rats at 12 month postimplantation (p < 0.01). In addition, the IL-2 and IL-4 serum levels at 12 month postimplantation were 2- and 2.8-fold higher as compared to short-term implantation (2 weeks and 1 month) and control rats (p < 0.05) whilst the IL-10 serum level at 1 and 12 month postimplantation was more than 100-fold higher in comparison with 2 week postimplantation and control rats (p < 0.001). Serum VEGF was detected only at 12 month postimplantation. All in all, we created a biocompatible PHBV/PCL small-diameter vascular graft with a high surface area to volume ratio. A long-term patency of biodegradable vascular grafts after implantation into the rat abdominal aorta and the absence of a considerable immune response confirmed a high biocompatibility of such construct and the possibility of its use as a vascular graft.

  16. Observations on placentome diameters in gestating West African ...

    African Journals Online (AJOL)

    ADEYEYE

    2015-09-09

    /10.4314/sokjvs.v13i3.4. Observations on placentome diameters in gestating West. African dwarf does experimentally infected with Trypanosoma brucei. OO Leigh. Department of Veterinary Surgery and Reproduction, ...

  17. Porosity Assessment for Different Diameters of Coir Lignocellulosic Fibers

    Science.gov (United States)

    da Luz, Fernanda Santos; Paciornik, Sidnei; Monteiro, Sergio Neves; da Silva, Luiz Carlos; Tommasini, Flávio James; Candido, Verônica Scarpini

    2017-10-01

    The application of natural lignocellulosic fibers (LCFs) in engineering composites has increased interest in their properties and structural characteristics. In particular, the inherent porosity of an LCF markedly affects its density and the adhesion to polymer matrices. For the first time, both open and closed porosities of a natural LCF, for different diameter ranges, were assessed. Fibers extracted from the mesocarp of the coconut fruit were investigated by nondestructive methods of density measurements and x-ray microtomography (microCT). It was found that, for all diameter ranges, the closed porosity is significantly higher than the open porosity. The total porosity increases with diameter to around 60% for coir fibers with more than 503 μm in diameter. The amount and characteristics of these open and closed porosities were revealed by t test and Weibull statistics as well as by microCT.

  18. Heritability of retinal vessel diameters and blood pressure

    DEFF Research Database (Denmark)

    Taarnhøj, Nina C B B; Larsen, Michael; Sander, Birgit

    2006-01-01

    PURPOSE: To assess the relative influence of genetic and environmental effects on retinal vessel diameters and blood pressure in healthy adults, as well as the possible genetic connection between these two characteristics. METHODS: In 55 monozygotic and 50 dizygotic same-sex healthy twin pairs......%-80%) for CRAE, 83% (95% CI: 73%-89%) for CRVE, and 61% (95% CI: 44%-73%) for mean arterial blood pressure (MABP). Retinal artery diameter decreased with increasing age and increasing arterial blood pressure. Mean vessel diameters in the population were 165.8 +/- 14.9 microm for CRAE, 246.2 +/- 17.7 microm...... for CRVE, and 0.67 +/- 0.05 microm for AVR. No significant influence on artery or vein diameters was found for gender, smoking, body mass index (BMI), total cholesterol, fasting blood glucose, or 2-hour oral glucose tolerance test values. CONCLUSIONS: In healthy young adults with normal blood pressure...

  19. Diameter modulation of vertically aligned single-walled carbon nanotubes.

    Science.gov (United States)

    Xiang, Rong; Einarsson, Erik; Murakami, Yoichi; Shiomi, Junichiro; Chiashi, Shohei; Tang, Zikang; Maruyama, Shigeo

    2012-08-28

    We demonstrate wide-range diameter modulation of vertically aligned single-walled carbon nanotubes (SWNTs) using a wet chemistry prepared catalyst. In order to ensure compatibility to electronic applications, the current minimum mean diameter of 2 nm for vertically aligned SWNTs is challenged. The mean diameter is decreased to about 1.4 nm by reducing Co catalyst concentrations to 1/100 or by increasing Mo catalyst concentrations by five times. We also propose a novel spectral analysis method that allows one to distinguish absorbance contributions from the upper, middle, and lower parts of a nanotube array. We use this method to quantitatively characterize the slight diameter change observed along the array height. On the basis of further investigation of the array and catalyst particles, we conclude that catalyst aggregation-rather than Ostwald ripening-dominates the growth of metal particles.

  20. Deriving muscle fiber diameter from recorded single fiber potential.

    Science.gov (United States)

    Zalewska, Ewa

    2017-12-01

    The aim of the study was to estimate muscle fiber diameters through analysis of single muscle fiber potentials (SFPs) recorded in the frontalis muscle of a healthy subject. Our previously developed analytical and graphic method to derive fiber diameter from the analysis of the negative peak duration and the amplitude of SFP, was applied to a sample of ten SFPs recorded in vivo. Muscle fiber diameters derived from the simulation method for the sample of frontalis muscle SFPs are consistent with anatomical data for this muscle. The results confirm the utility of proposed simulation method. Outlying data could be considered as the result of a contribution of other fibers to the potential recorded using an SFEMG electrode. Our graphic tool provides a rapid estimation of muscle fiber diameter. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Axon diameter mapping in crossing fibers with diffusion MRI

    DEFF Research Database (Denmark)

    Zhang, Hui; Dyrby, Tim B; Alexander, Daniel C

    2011-01-01

    This paper proposes a technique for a previously unaddressed problem, namely, mapping axon diameter in crossing fiber regions, using diffusion MRI. Direct measurement of tissue microstructure of this kind using diffusion MRI offers a new class of biomarkers that give more specific information about...... tissue than measures derived from diffusion tensor imaging. Most existing techniques for axon diameter mapping assume a single axon orientation in the tissue model, which limits their application to only the most coherently oriented brain white matter, such as the corpus callosum, where the single...... model to enable axon diameter mapping in voxels with crossing fibers. We show in simulation that the technique can provide robust axon diameter estimates in a two-fiber crossing with the crossing angle as small as 45 degrees. Using ex vivo imaging data, we further demonstrate the feasibility...

  2. Ion implantation control system

    International Nuclear Information System (INIS)

    Gault, R. B.; Keutzer, L. L.

    1985-01-01

    A control system is disclosed for an ion implantation system of the type in which the wafers to be implanted are mounted around the periphery of a disk which rotates and also moves in a radial direction relative to an ion beam to expose successive sections of each wafer to the radiation. The control system senses beam current which passes through one or more apertures in the disk and is collected by a Faraday cup. This current is integrated to obtain a measure of charge which is compared with a calculated value based upon the desired ion dosage and other parameters. The resultant controls the number of incremental steps the rotating disk moves radially to expose the adjacent sections of each wafer. This process is continued usually with two or more traverses until the entire surface of each wafer has been implanted with the proper ion dosage

  3. Implantation for tribological applications

    International Nuclear Information System (INIS)

    Leutenecker, R.; Cao-Minh, U.; Overbeck, R.

    1992-08-01

    Empirical results on the strength enhancement of steels by N- and B-implantation should be explained from a materials science point of view. The methods applied were X-ray diffractometry and element depth profiling. The investigations of N-implanted steels focussed on the nitride formation in selected model materials and, with respect to applications, in: X90 CrMoV and S 6-5-2 tool steels, austenite X10 CrNiTi189 as well as in hard chromium plates. Main topic in B-implanted steels were the transformations: crystalline Fe-phase - amorphous Fe-B-phase - crystalline boride phases. The result is an improvement in process control by first an insight into the strength enhancing mechanisms and second in into their generation depending on the materials microstructure and the process parameter. (orig.). 101 figs., 16 tabs., 15 refs [de

  4. Dental implants: A review.

    Science.gov (United States)

    Guillaume, B

    2016-12-01

    A high number of patients have one or more missing tooth and it is estimated that one in four American subjects over the age of 74 have lost all their natural teeth. Many options exist to replace missing teeth but dental implants have become one of the most used biomaterial to replace one (or more) missing tooth over the last decades. Contemporary dental implants made with titanium have been proven safe and effective in large series of patients. This review considers the main historical facts concerned with dental implants and present the different critical factors that will ensure a good osseo-integration that will ensure a stable prosthesis anchorage. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. Catalytic growth of carbon nanotubes with large inner diameters

    Directory of Open Access Journals (Sweden)

    WEI REN ZHONG

    2005-02-01

    Full Text Available Carbon nanotubes (2.4 g/g catalyst, with large inner diameters were successfully synthesized through pyrolysis of methane on a Ni–Cu–Al catalyst by adding sodium carbonate into the carbon nanotubes growth system. The inner diameter of the carbon nanotubes prepared by this method is about 20–60 nm, while their outer diameter is about 40–80 nm. Transmission electron microscopy and X-ray diffraction were employed to investigate the morphology and microstructures of the carbon nanotubes. The analyses showed that these carbon nanotubes have large inner diameters and good graphitization. The addition of sodium carbonate into the reaction system brings about a slight decrease in the methane conversion and the yield of carbon. The experimental results showed that sodium carbonate is a mildly toxic material which influenced the catalytic activity of the Ni–Cu–Al catalyst and resulted in the formation of carbon nanotubes with large inner diameters. The growth mechanism of the carbon nanotubes with large inner diameters is discussed in this paper.

  6. Tribology of implantation bilayers

    International Nuclear Information System (INIS)

    Pivin, J.C.

    1989-01-01

    The mechanical behaviour of implantation films must be analysed in terms of bilayer rheology (laws of mechanical behaviour). Tribology takes into account thermodynamical, chemical and metallurgical parameters to interpret the friction properties of a system as a whole. One can distinguish between alloying effects of ion implantation and structural modifications. Alloying affects the basic properties of the crystal: elasticity, cohesion, mobility of planar defects, and its surface electronic structure, which determines the reactivity with the atmosphere or the friction counterpart (adhesion). Radiation damage and phase changes act more particularly on the modes of gliding and climbing of dislocations, and fracture mechanisms. 105 refs.; 11 figs.; 1 table

  7. [Tinnitus and implants].

    Science.gov (United States)

    Despreaux, G; Tison, P; Van Den Abbeele, T; Moine, A; Frachet, B

    1990-01-01

    The experience with cochlear implantation at Avicenne hospital prompted us to carry out a retrospective study on tinnitus in a population of operated patients. Improvement or disappearance of the symptoms was noted in all cases. These results, which partly match those found in the literature, are probably produced by rehabilitation inhibiting the "deafferentation" mechanisms in analogy with pain phenomena. In some precise cases, which are described, they led us to proposing implantation even though the main, if not sole, complaint of the patient was tinnitus.

  8. Evaluation of a xenogeneic acellular collagen matrix as a small-diameter vascular graft in dogs--preliminary observations.

    Science.gov (United States)

    Nemcova, S; Noel, A A; Jost, C J; Gloviczki, P; Miller, V M; Brockbank, K G

    2001-01-01

    Autogenous veins are the materials of choice for arterial reconstruction. In the absence of autogenous material, prosthetic materials are used. However, vascular prostheses of less than 0.4 cm in diameter have low long-term patency. This study was designed to determine if cells would infiltrate an engineered xenogeneic biomaterial used as a small diameter arterial graft in dogs and, if so, to determine the phenotype of the infiltrating cells. Nine acellular xenogeneic grafts (0.4 cm in diameter, 5 cm long), composed of porcine collagen derived from the submucosa of the small intestine and type I bovine collagen, were implanted as end to-end interposition grafts in femoral arteries of five male mongrel dogs (total of nine grafts). All dogs received daily aspirin (325 mg). Patency of implanted grafts was monitored weekly by Duplex ultrasonography. After 9 weeks, or earlier in case of blood flow reduction by at least 75%, grafts were explanted and prepared for light or electron microscopy to evaluate cellularization. Eight of nine grafts remained patent up to 9 weeks. At explant, diameters were 0.31 +/- 0.02 cm at the midgraft, and 0.14 +/- 0.01 and 0.19 +/- 0.01 cm at the proximal and distal anastomoses. At explant, cells of mesenchymal origin (endothelial cells, smooth muscle cells, myofibroblasts) were embedded in the extracellular matrix of the graft scaffold. Minimal evidence of cellular inflammatory reaction and no aneurysmal dilatation or thrombus formation was detected. Variable degrees of hyperplasia were present at proximal and distal anastomoses. This preliminary study demonstrates that a collagen-based xenogeneic biomaterial provides a scaffold for cellularization when used for arterial reconstruction in dogs.

  9. Recent advances in dental implants.

    Science.gov (United States)

    Hong, Do Gia Khang; Oh, Ji-Hyeon

    2017-12-01

    Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

  10. Untreated silicone breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse M; Conrad, Carsten

    2004-01-01

    Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untre...

  11. Los implantes MG-OSSEOUS: Estudio multicéntrico retrospectivo MG-OSSEOUS implants: A multicentric retrospective study

    Directory of Open Access Journals (Sweden)

    E. Serrano Caturla

    2006-12-01

    commercial implants. Material and methodology. This is a retrospective multicentric study coordinated by a company called Scientific Management in O&SS (Barcelona, Spain. 1001 dental implants were placed in 247 patients and 328 prostheses were designed between 2004 and 2005, with a follow-up of two years. All implants were loaded with prostheses. We detail and analyze each implant, according to the diameter, length, position, surgical timing, loadings, design and types of prostheses and complementary surgical procedures, either synchronic or metachronic. Results. After the statistical method was homogenized, we were able to report an overall implant survival rate of 97.8% with monitoring of two years. The failures depending on the peculiarities of each clinical case are provided. No prosthetic failures are reported. Discussion. The criteria and indications applied by the professionals to the MG-OSSEOUS implants are standardized depending on the clinical case. Our results are compared with the international scientific literature, past and present, with these procedures totally agreeing with those found in the history of implantology. Finally, our survey is compared with those published by the Branemark team. Conclusion. The mixture between the quality of the MGOSSEOUS implants and the scientifically supported criteria regarding the implants, reveals an implant failure of 2.2% over two years, with a survival of 100% of both the replaced implants and the loaded prostheses.

  12. Elements of implant-supported rehabilitation planning in patients with bruxism.

    Science.gov (United States)

    Sarmento, Hugo Ramalho; Dantas, Raquel Venâncio Fernandes; Pereira-Cenci, Tatiana; Faot, Fernanda

    2012-11-01

    The rehabilitation of partial or completely edentulous patients with implant-supported prostheses has been widely used, achieving high success rates. However, many studies consider the presence of bruxism as a contraindication for this treatment modality. The purpose of this study was to revise the literature and identify risk factors in implant-supported rehabilitation planning in subjects with bruxism. Available literature was searched through Medline, with no time limit, including only studies in English. Topics discussed were etiology of bruxism and its implications on dental implants, biomechanical considerations regarding the overload on dental implants, and methods to prevent the occurrence of overloads in implant-supported prostheses. The rehabilitation of bruxers using implant-supported prostheses, using implants with adequate length and diameter, as well as proper positioning seems to be a reliable treatment, with reduced risks of failure. Bruxism control through the use of a nightguard by rigid occlusal stabilization appliance relieved in the region of implants is highly indicated. Although it is clear that implant-supported rehabilitation of patients with bruxism requires adequate planning and follow-up, well-designed randomized controlled trials are needed to provide reliable evidence on the long-term success of this treatment modality.

  13. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  14. The effect of mucosal cuff shrinkage around dental implants during healing abutment replacement.

    Science.gov (United States)

    Nissan, J; Zenziper, E; Rosner, O; Kolerman, R; Chaushu, L; Chaushu, G

    2015-10-01

    Soft tissue shrinkage during the course of restoring dental implants may result in biological and prosthodontic difficulties. This study was conducted to measure the continuous shrinkage of the mucosal cuff around dental implants following the removal of the healing abutment up to 60 s. Individuals treated with implant-supported fixed partial dentures were included. Implant data--location, type, length, diameter and healing abutments' dimensions--were recorded. Mucosal cuff shrinkage, following removal of the healing abutments, was measured in bucco-lingual direction at four time points--immediately after 20, 40 and 60 s. anova was used to for statistical analysis. Eighty-seven patients (49 women and 38 men) with a total of 311 implants were evaluated (120 maxilla; 191 mandible; 291 posterior segments; 20 anterior segments). Two-hundred and five (66%) implants displayed thick and 106 (34%) thin gingival biotype. Time was the sole statistically significant parameter affecting mucosal cuff shrinkage around dental implants (P < 0.001). From time 0 to 20, 40 and 60 s, the mean diameter changed from 4.1 to 4.07, 3.4 and 2.81 mm, respectively. The shrinkage was 1%, 17% and 31%, respectively. The gingival biotype had no statistically significant influence on mucosal cuff shrinkage (P = 0.672). Time required replacing a healing abutment with a prosthetic element should be minimised (up to 20/40 s), to avoid pain, discomfort and misfit. © 2015 John Wiley & Sons Ltd.

  15. A Mechanistic Model of Onset of Flow Instability Due to Mergence of Bubble Layers in a Vertical Narrow Rectangular Channel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Juh Yung; Chang, Soon Heung; Jeong, Yong [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    The onset of flow instability (OFI) is the one of important boiling phenomena since it may induce the premature critical heat flux (CHF) at the lowest heat flux level due to sudden flow excursion in a single channel of multichannel configuration. Especially prediction of OFI for narrow rectangular channel is very crucial in relevant to thermal-hydraulic design and safety analysis of open pool-type research reactors (RRs) using plate-type fuels. Based on high speed video (HSV) technique, the authors observed and determined that OFI and the minimum premature CHF in a narrow rectangular channel are induced by abrupt pressure drop fluctuation due to the mergence of facing bubble boundary layers (BLs) on opposite boiling surfaces. In this study, new mechanistic OFI model for narrow rectangular channel heated on both sides has been derived, which satisfies with the real triggering phenomena. Force balance approach was used for modeling of the maximum BLT since the quantity is comparable to the bubble departure diameter. From the validation with OFI database, it was shown that the new model fairly well predicts OFI heat flux for wide range of conditions.

  16. A clustering analysis of lipoprotein diameters in the metabolic syndrome

    Directory of Open Access Journals (Sweden)

    Frazier-Wood Alexis C

    2011-12-01

    Full Text Available Abstract Background The presence of smaller low-density lipoproteins (LDL has been associated with atherosclerosis risk, and the insulin resistance (IR underlying the metabolic syndrome (MetS. In addition, some research has supported the association of very low-, low- and high-density lipoprotein (VLDL HDL particle diameters with components of the metabolic syndrome (MetS, although this has been the focus of less research. We aimed to explore the relationship of VLDL, LDL and HDL diameters to MetS and its features, and by clustering individuals by their diameters of VLDL, LDL and HDL particles, to capture information across all three fractions of lipoprotein into a unified phenotype. Methods We used nuclear magnetic resonance spectroscopy measurements on fasting plasma samples from a general population sample of 1,036 adults (mean ± SD, 48.8 ± 16.2 y of age. Using latent class analysis, the sample was grouped by the diameter of their fasting lipoproteins, and mixed effects models tested whether the distribution of MetS components varied across the groups. Results Eight discrete groups were identified. Two groups (N = 251 were enriched with individuals meeting criteria for the MetS, and were characterized by the smallest LDL/HDL diameters. One of those two groups, one was additionally distinguished by large VLDL, and had significantly higher blood pressure, fasting glucose, triglycerides, and waist circumference (WC; P Conclusions While small LDL diameters remain associated with IR and the MetS, the occurrence of these in conjunction with a shift to overall larger VLDL diameter may identify those with the highest fasting glucose, TG and WC within the MetS. If replicated, the association of this phenotype with more severe IR-features indicated that it may contribute to identifying of those most at risk for incident type II diabetes and cardiometabolic disease.

  17. Failure Diameter of PBX 9502: Simulations with the SURFplus model

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-03

    SURFplus is a reactive burn model for high explosives aimed at modelling shock initiation and propagation of detonation waves. It utilizes the SURF model for the fast hot-spot reaction plus a slow reaction for the energy released by carbon clustering. A feature of the SURF model is that there is a partially decoupling between burn rate parameters and detonation wave properties. Previously, parameters for PBX 9502 that control shock ini- tiation had been calibrated to Pop plot data (distance-of-run to detonation as a function of shock pressure initiating the detonation). Here burn rate parameters for the high pres- sure regime are adjusted to t the failure diameter and the limiting detonation speed just above the failure diameter. Simulated results are shown for an uncon ned rate stick when the 9502 diameter is slightly above and slightly below the failure diameter. Just above the failure diameter, in the rest frame of the detonation wave, the front is sonic at the PBX/air interface. As a consequence, the lead shock in the neighborhood of the interface is supported by the detonation pressure in the interior of the explosive rather than the reaction immediately behind the front. In the interior, the sonic point occurs near the end of the fast hot-spot reaction. Consequently, the slow carbon clustering reaction can not a ect the failure diameter. Below the failure diameter, the radial extent of the detonation front decreases starting from the PBX/air interface. That is, the failure starts at the PBX boundary and propagates inward to the axis of the rate stick.

  18. Diameter measurements of polystyrene particles with atomic force microscopy

    International Nuclear Information System (INIS)

    Garnaes, J

    2011-01-01

    The size of (nano) particles is a key parameter used in controlling their function. The particle size is also important in order to understand their physical and chemical properties and regulate their number in health and safety issues. In this work, the geometric diameters of polystyrene spheres of nominal diameter 100 nm are measured using atomic force microscopy. The measurements are based on the apex height and on the average distance between neighbouring spheres when they form a close-packed monolayer on a flat mica substrate. The most important influence parameters for the determination of the geometric diameter are the lateral air gaps and deformation of the spheres. The lateral air gaps are caused by significant size variations of the individual spheres, and a correction is calculated based on the simulation of packing of spheres. The deformation of the spheres is caused mainly by capillary forces acting when they are in contact with each other or with the mica substrate. Based on calculated capillary forces and the literature values of the elastic properties of the polystyrene and mica, the deformation is estimated to be 2 nm with a standard uncertainty of 2 nm. The geometric diameter of the polystyrene spheres was measured with a combined standard uncertainty of ≈3 nm. The measured vertical diameter of 92.3 nm and the certified mobility equivalent diameter measured by differential mobility analysis (DMA) are marginally consistent at a confidence level of 95%. However, the measured lateral geometric diameter was 98.9 nm and is in good agreement with DMA

  19. Semiconductor Ion Implanters

    International Nuclear Information System (INIS)

    MacKinnon, Barry A.; Ruffell, John P.

    2011-01-01

    In 1953 the Raytheon CK722 transistor was priced at $7.60. Based upon this, an Intel Xeon Quad Core processor containing 820,000,000 transistors should list at $6.2 billion! Particle accelerator technology plays an important part in the remarkable story of why that Intel product can be purchased today for a few hundred dollars. Most people of the mid twentieth century would be astonished at the ubiquity of semiconductors in the products we now buy and use every day. Though relatively expensive in the nineteen fifties they now exist in a wide range of items from high-end multicore microprocessors like the Intel product to disposable items containing 'only' hundreds or thousands like RFID chips and talking greeting cards. This historical development has been fueled by continuous advancement of the several individual technologies involved in the production of semiconductor devices including Ion Implantation and the charged particle beamlines at the heart of implant machines. In the course of its 40 year development, the worldwide implanter industry has reached annual sales levels around $2B, installed thousands of dedicated machines and directly employs thousands of workers. It represents in all these measures, as much and possibly more than any other industrial application of particle accelerator technology. This presentation discusses the history of implanter development. It touches on some of the people involved and on some of the developmental changes and challenges imposed as the requirements of the semiconductor industry evolved.

  20. Implantable enzyme amperometric biosensors.

    Science.gov (United States)

    Kotanen, Christian N; Moussy, Francis Gabriel; Carrara, Sandro; Guiseppi-Elie, Anthony

    2012-05-15

    The implantable enzyme amperometric biosensor continues as the dominant in vivo format for the detection, monitoring and reporting of biochemical analytes related to a wide range of pathologies. Widely used in animal studies, there is increasing emphasis on their use in diabetes care and management, the management of trauma-associated hemorrhage and in critical care monitoring by intensivists in the ICU. These frontier opportunities demand continuous indwelling performance for up to several years, well in excess of the currently approved seven days. This review outlines the many challenges to successful deployment of chronically implantable amperometric enzyme biosensors and emphasizes the emerging technological approaches in their continued development. The foreign body response plays a prominent role in implantable biotransducer failure. Topics considering the approaches to mitigate the inflammatory response, use of biomimetic chemistries, nanostructured topographies, drug eluting constructs, and tissue-to-device interface modulus matching are reviewed. Similarly, factors that influence biotransducer performance such as enzyme stability, substrate interference, mediator selection and calibration are reviewed. For the biosensor system, the opportunities and challenges of integration, guided by footprint requirements, the limitations of mixed signal electronics, and power requirements, has produced three systems approaches. The potential is great. However, integration along the multiple length scales needed to address fundamental issues and integration across the diverse disciplines needed to achieve success of these highly integrated systems, continues to be a challenge in the development and deployment of implantable amperometric enzyme biosensor systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. HA-Coated Implant

    DEFF Research Database (Denmark)

    Daugaard, Henrik; Søballe, Kjeld; Bechtold, Joan E

    2014-01-01

    of improving the fixation of implants. Of these, hydroxyapatite (HA) is the most widely used and most extensively investigated. HA is highly osseoconductive, and the positive effect is well documented in both basic and long-term clinical research [1–6]. This chapter describes experimental and clinical studies...

  2. Middle ear implants

    Directory of Open Access Journals (Sweden)

    K S Gangadhara Somayaji

    2013-01-01

    Full Text Available Hearing loss is becoming more common in the society living in cities with lot of background noise around, and frequent use of gadgets like mobile phones, MP3s, and IPods are adding to the problem. The loss may involve the conductive or perceptive pathway. Majority of the patients with conductive hearing loss will revert back to normal hearing levels with medical and/or surgical treatment. However, in sensorineural hearing loss, many factors are involved in the management. Though traditionally hearing aids in various forms are the most commonly used modality in managing these patients, there are some drawbacks associated with them. Implantable middle ear amplifiers represent the most recent breakthrough in the management of hearing loss. Middle ear implants are surgically implanted electronic devices that aim to correct hearing loss by stimulating the ossicular chain or middle ear. Of late, they are also being used in the management of congenital conductive hearing loss and certain cases of chronic otitis media with residual hearing loss. The article aims to provide general information about the technology, indications and contraindications, selection of candidates, available systems, and advantages of middle ear implants. (MEI

  3. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne

    2011-01-01

    the period 1999 to 2006; 239 one-stage procedures and 353 two-stage procedures. The postoperative course through November 2009 was evaluated by cumulative incidence adjusting for competing risks for the selected outcomes; hematoma, infection, seroma, implant rupture, severe capsular contracture (modified...

  4. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  5. The fabrication of silicon nanostructures by focused-ion-beam implantation and TMAH wet etching

    International Nuclear Information System (INIS)

    Sievilae, Paeivi; Chekurov, Nikolai; Tittonen, Ilkka

    2010-01-01

    Local gallium implantation of silicon by a focused ion beam (FIB) has been used to create a mask for anisotropic tetramethylammonium hydroxide (TMAH) wet etching. The dependence of the etch stop properties of gallium-doped silicon on the implanted dose has been investigated and a dose of 4 x 10 13 ions cm -2 has been determined to be the threshold value for achieving observable etching resistance. Only a thin, approx. 50 nm, surface layer is found to be durable enough to serve as a mask with a high selectivity of at least 2000:1 between implanted and non-implanted areas. The combined FIB-TMAH process has been used to generate various types of 3D nanostructures including nanochannels separated by thin vertical sidewalls with aspect ratios up to 1:30, ultra-narrow (approx. 25 nm) freestanding bridges and cantilevers, and gratings with a resolution of 20 lines μm -1 .

  6. A 5-year clinical and computerized tomographic implant follow-up in sinus-lifted maxillae and native bone.

    Science.gov (United States)

    Sbordone, Carolina; Toti, Paolo; Ramaglia, Luca; Guidetti, Franco; Sbordone, Ludovico; Martuscelli, Ranieri

    2014-09-01

    The present study analysed apical and marginal bone remodelling around dental implants placed in both maxillary (sinus elevated with particulated autogenous osseous graft) and corresponding native bone areas, with a follow-up of 5 years. The clinical survival of implants was also observed. In this retrospective chart review, 27 patients were enrolled, with 55 dental implants inserted from 2000 to 2006, 26 of which were followed (one implant per patient); if required, patients were treated via sinus lift with autogenous bone and particulate technique. The internal controls were implants positioned in native areas beneath the sinus. Radiologic survey was assessed via computerized tomographic analysis measuring apical bone level (ABL) and marginal bone level (MBL), at 1- (T1 ), 3- (T2 ) and 5 years (T3 ), around implants (buccal, b; palatal, p; mesial, m; and distal sides, d). Clinical probing depth (CPD) and clinical attachment level (CAL) for all the four peri-implant aspects were measured. Cumulative survival rate (CSR) and survival rate (SR) of implants were calculated. Significances for paired and unpaired comparisons were searched for. A significant degree of apical resorption was recorded between T1 and T3 for the mesial particulate group; again, a significant difference was discovered between the native and particulate procedures for mABL. A further feature was discovered for the particulate procedure, for which ABLs resulted negative at least for three of the aspects. Regarding MBL measurements, similar behaviours were revealed using time-comparison analysis for the two procedures at the buccal aspect. Comparisons among diameters, irrespective of the procedure, showed that resorption times for the bMBL were shorter as the diameter of the implant became wider. The implant CSR was 92% in native areas (two failures/25 implants) and 93.3% in sinuses lifted with particulate bone (two failures/30 implants). The results suggest that a protrusion of the implant

  7. Bone integration capability of nanopolymorphic crystalline hydroxyapatite coated on titanium implants

    Directory of Open Access Journals (Sweden)

    Suzuki T

    2012-02-01

    Full Text Available Masahiro Yamada*, Takeshi Ueno*, Naoki Tsukimura, Takayuki Ikeda, Kaori Nakagawa, Norio Hori, Takeo Suzuki, Takahiro OgawaLaboratory of Bone and Implant Sciences, The Weintraub Center for Reconstructive Biotechnology, Division of Advanced Prosthodontics, Biomaterials and Hospital Dentistry, UCLA School of Dentistry, Los Angeles, CA, USA *These authors contributed equally to this workAbstract: The mechanism by which hydroxyapatite (HA-coated titanium promotes bone–implant integration is largely unknown. Furthermore, refining the fabrication of nanostructured HA to the level applicable to the mass production process for titanium implants is challenging. This study reports successful creation of nanopolymorphic crystalline HA on microroughened titanium surfaces using a combination of flame spray and low-temperature calcination and tests its biological capability to enhance bone–implant integration. Sandblasted microroughened titanium implants and sandblasted + HA-coated titanium implants were subjected to biomechanical and histomorphometric analyses in a rat model. The HA was 55% crystallized and consisted of nanoscale needle-like architectures developed in various diameters, lengths, and orientations, which resulted in a 70% increase in surface area compared to noncoated microroughened surfaces. The HA was free from impurity contaminants, with a calcium/phosphorus ratio of 1.66 being equivalent to that of stoichiometric HA. As compared to microroughened implants, HA-coated implants increased the strength of bone–implant integration consistently at both early and late stages of healing. HA-coated implants showed an increased percentage of bone–implant contact and bone volume within 50 µm proximity of the implant surface, as well as a remarkably reduced percentage of soft tissue intervention between bone and the implant surface. In contrast, bone volume outside the 50 µm border was lower around HA-coated implants. Thus, this study

  8. Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2.

    Science.gov (United States)

    Hong, Christine; Truong, Peter; Song, Ha Na; Wu, Benjamin M; Moon, Won

    2011-11-01

    To assess the mechanical stability of a newly revised orthodontic mini-implant design (N2) compared with a design introduced in Part 1 of the study (N1) and the most widely-used commercially-available design (CA). To evaluate the mean buccal bone thickness of maxillary and mandibular posterior teeth using cone-beam computed tomography (CBCT). From the CBCT scans of 20 patients, six tomographic cross-sections were generated for each tooth. Buccal bone thickness was measured from the most convex point on the bone to the root surface. CA (1.5 mm in diameter and 6 mm in length), N1, and N2 (shorter and narrower than N1) were inserted in simulated bone with cortical and trabecular bone layers. Mechanical stability was compared in vitro through torque and lateral displacement tests. The bone thickness ranged from 2.26 to 3.88 mm. Maximum insertion torque was decreased significantly in N2 compared to N1. However, force levels for all displacement distances and torque ratio were the highest in N2, followed by N1 and CA (α = .05). Both torque and lateral displacement tests highlighted the enhanced stability of N2 compared with CA. Design revisions to N1 effectively mitigated N1's high insertion torque and thus potentially reduced microdamage to the surrounding bone. The N2 design is promising as evidenced by enhanced stability and high mechanical efficiency. Moreover, N2 is not limited to placement in interradicular spaces and has the capacity to be placed in the buccal bone superficial to the root surface with diminished risk of endangering nearby anatomic structures during placement and treatment.

  9. Low-dose rhBMP2/7 heterodimer to reconstruct peri-implant bone defects: a micro-CT evaluation

    NARCIS (Netherlands)

    Wang, J.; Zheng, Y.; Zhao, J.; Liu, T.; Gao, L.; Gu, Z.; Wu, G.

    2012-01-01

    Objectives To delineate the dynamic micro-architectures of bone induced by low-dose bone morphogenetic protein (BMP)-2/7 heterodimer in peri-implant bone defects compared to BMP2 and BMP7 homodimer. Material and Methods Peri-implant bone defects (8 mm in diameter, 4 mm in depth) were created

  10. Narrow power deposition profiles on the JET divertor target

    International Nuclear Information System (INIS)

    Lingertat, J.; Laux, M.; Monk, R.

    2001-01-01

    One of the key unresolved issues in the design of a future fusion reactor is the power handling capability of the divertor target plates. Earlier we reported on the existence of narrow power deposition profiles in JET, obtained mainly from Langmuir probe measurements. We repeated these measurements in the MkI, MkII and MkIIGB divertor configurations with an upgraded probe system, which allowed us to study the profile shape in more detail. The main results of this study are: In NB heated discharges the electron temperature and power flux at the outer target show a distinct peak of ∼5 mm half-width near the separatrix strike point. The corresponding profiles on the inner target do not show a similar feature. The height of the narrow peak increases with NB heating power and decreases with deuterium and impurity gas puffing. Ion orbit losses are suggested as a possible explanation of the observed profile shape

  11. Experimental research on flow instability in vertical narrow annuli

    Institute of Scientific and Technical Information of China (English)

    WU Geping; QIU Suizheng; SU Guanghui; JIA Dounan

    2007-01-01

    A narrow annular test section of 1.5mm gap and 1800mm length was designed and manufactured, with good tightness and insulation. Experiments were carried out to investigate characteristics of flow instability of forced-convection in vertical narrow annuli. Using distilled water as work fluid, the experiments were conducted at pressures of 1.0~3.0 MPa, mass flow rates of 3.0~25 kg/h, heating power of 3.0~ 6.5kW and inlet fluid temperature of 20 ℃, 40 ℃ or 60℃. It was found that flow instability occured with fixed inlet condition and heating power when mass flow rate was below a special value. Effects of inlet subcooling, system pressure and mass flow rate on the system behavior were studied and the instability region was given.

  12. Coulomb and nuclear excitations of narrow resonances in 17Ne

    Directory of Open Access Journals (Sweden)

    J. Marganiec

    2016-08-01

    Full Text Available New experimental data for dissociation of relativistic 17Ne projectiles incident on targets of lead, carbon, and polyethylene targets at GSI are presented. Special attention is paid to the excitation and decay of narrow resonant states in 17Ne. Distributions of internal energy in the O15+p+p three-body system have been determined together with angular and partial-energy correlations between the decay products in different energy regions. The analysis was done using existing experimental data on 17Ne and its mirror nucleus 17N. The isobaric multiplet mass equation is used for assignment of observed resonances and their spins and parities. A combination of data from the heavy and light targets yielded cross sections and transition probabilities for the Coulomb excitations of the narrow resonant states. The resulting transition probabilities provide information relevant for a better understanding of the 17Ne structure.

  13. Period effects, cohort effects, and the narrowing gender wage gap.

    Science.gov (United States)

    Campbell, Colin; Pearlman, Jessica

    2013-11-01

    Despite the abundance of sociological research on the gender wage gap, questions remain. In particular, the role of cohorts is under investigated. Using data from the Current Population Survey, we use age-period-cohort analysis to uniquely estimate age, period, and cohort effects on the gender wage gap. The narrowing of the gender wage gap that occurred between 1975 and 2009 is largely due to cohort effects. Since the mid-1990s, the gender wage gap has continued to close absent of period effects. While gains in female wages contributed to declines in the gender wage gap for cohorts born before 1950, for later cohorts the narrowing of the gender wage gap is primarily a result of declines in male wages. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Experimental Study on CHF in a Hemispherical Narrow Gap

    International Nuclear Information System (INIS)

    Jeong, J.H.; Park, R.J.; Kang, K.H.; Kim, S.B.; Kim, H.D.

    1999-01-01

    As a part of the SONATA-IV program, KAERI is conducting an experimental investigation of critical heat flux(CHF) in hemispherical narrow gaps. A visualization experiment, VISU-II, was done as the first step to get a visual observation of the flow behaviour inside a hemispherical gap and to understand the CHF-triggering mechanism. It was observed that the counter-current flow limitation (CCFL) phenomenon prevented water from wetting the heater surface and induced CHF. The CHFG (Critical Heat Flux in Gap) test is now being performed to measure the CHF and to investigate the inherent cooling mechanism in hemispherical narrow gaps. Temperature measurements over the heater surface show that the two-phase flow behaviour inside the gaps could be quite different from the other usual CHF experiments. The measured CHF points are lower than the predictions by existing empirical correlations based on the data measured with small-scale horizontal plates and vertical annulus. (authors)

  15. Period Effects, Cohort Effects, and the Narrowing Gender Wage Gap

    Science.gov (United States)

    Campbell, Colin; Pearlman, Jessica

    2015-01-01

    Despite the abundance of sociological research on the gender wage gap, questions remain. In particular, the role of cohorts is under investigated. Using data from the Current Population Survey, we use Age-Period-Cohort analysis to uniquely estimate age, period, and cohort effects on the gender wage gap. The narrowing of the gender wage gap that occurred between 1975 and 2009 is largely due to cohort effects. Since the mid-1990s, the gender wage gap has continued to close absent of period effects. While gains in female wages contributed to declines in the gender wage gap for cohorts born before 1950, for later cohorts the narrowing of the gender wage gap is primarily a result of declines in male wages. PMID:24090861

  16. On the performance of small diameter gas cyclones

    International Nuclear Information System (INIS)

    Halasz, Marcos Roberto Teixeira

    2002-02-01

    Small diameter cyclones represent a potential alternative for the removal of small diameter particles from gaseous mixtures as well as the environmental control of their emission. In order to establish feasible configurations of a small diameter cyclone applied in the separation of solid particles dispersed in a gas and considering a large quantify of experimental data in literature, neural networks were used to estimate the equipment grade efficiency and pressure drop. In order to evaluate a performance of many small diameters configurations and analysis was carried of parametrical sensibility which determines the most important variables on separation efficiency determination. A set of experimental runs was carried out in a lab-scale mini-cyclone in order to obtain the separation efficiency and pressure drop for different configurations, and evaluate the feasibility of coupling a post-cyclone device to improve the equipment overall performance. The cyclones used presented diameters of 0.03 and 0.05 m and the remaining dimensions varied proportionally about those found in Stairmand high-efficiency cyclones. Experimental separation efficiencies up to 99% were obtained in this work. These results confirm the feasibility of the experimental set-up configuration proposed. (author)

  17. Parametric Probability Distribution Functions for Axon Diameters of Corpus Callosum

    Directory of Open Access Journals (Sweden)

    Farshid eSepehrband

    2016-05-01

    Full Text Available Axon diameter is an important neuroanatomical characteristic of the nervous system that alters in the course of neurological disorders such as multiple sclerosis. Axon diameters vary, even within a fiber bundle, and are not normally distributed. An accurate distribution function is therefore beneficial, either to describe axon diameters that are obtained from a direct measurement technique (e.g., microscopy, or to infer them indirectly (e.g., using diffusion-weighted MRI. The gamma distribution is a common choice for this purpose (particularly for the inferential approach because it resembles the distribution profile of measured axon diameters which has been consistently shown to be non-negative and right-skewed. In this study we compared a wide range of parametric probability distribution functions against empirical data obtained from electron microscopy images. We observed that the gamma distribution fails to accurately describe the main characteristics of the axon diameter distribution, such as location and scale of the mode and the profile of distribution tails. We also found that the generalized extreme value distribution consistently fitted the measured distribution better than other distribution functions. This suggests that there may be distinct subpopulations of axons in the corpus callosum, each with their own distribution profiles. In addition, we observed that several other distributions outperformed the gamma distribution, yet had the same number of unknown parameters; these were the inverse Gaussian, log normal, log logistic and Birnbaum-Saunders distributions.

  18. New technology for the control of narrow-gap semiconductors

    International Nuclear Information System (INIS)

    Antoniou, I.; Bozhevolnov, V.; Melnikov, Yu.; Yafyasov, A.

    2003-01-01

    We present the results of the year work in the frame of the EU ESPRIT Project 28890 NTCONGS 'New technology for the control of narrow-gap semiconductors'. This work has involved both theoretical and experimental study, as well as the development of new specific equipment, towards the creation of a new generation of nanoelectronic devices able to operate at 77 K and even at room temperature

  19. US images encoding envelope amplitude following narrow band filtering

    International Nuclear Information System (INIS)

    Sommer, F.G.; Stern, R.A.; Chen, H.S.

    1986-01-01

    Ultrasonic waveform data from phantoms having differing scattering characteristics and from normal and cirrhotic human liver in vivo were recorded within a standardized dynamic range and filtered with narrow band filters either above or below the mean recorded ultrasonic center frequency. Images created by mapping the amplitudes of received ultrasound following such filtration permitted dramatic differentiation, not discernible in conventional US images, of phantoms having differing scattering characteristics, and of normal and cirrhotic human livers

  20. Elongational viscosity of narrow molar mass distribution polystyrene

    DEFF Research Database (Denmark)

    Bach, Anders; Almdal, Kristoffer; Rasmussen, Henrik Koblitz

    2003-01-01

    Transient and steady elongational viscosity has been measured for two narrow molar mass distribution polystyrene melts of molar masses 200 000 and 390 000 by means of a filament stretching rheometer. Total Hencky strains of about five have been obtained. The transient elongational viscosity rises...... above the linear viscoelastic prediction at intermediate strains, indicating strain hardening. The steady elongational viscosities are monotone decreasing functions of elongation rate. At elongation rates larger than the inverse reptation time, the steady elongational viscosity scales linearly...

  1. Generation of narrow peaks in spectroscopy of charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Dubbers, Dirk, E-mail: dubbers@physi.uni-heidelberg.de; Schmidt, Ulrich, E-mail: ulrich.schmidt@physi.uni-heidelberg.de

    2016-11-21

    In spectroscopy of charged particles, narrow peaks may appear in continuous spectra if magnetic transport of the particles is involved. These artefacts, which so far have escaped the attention of investigators, can develop whenever geometric detection efficiency is less than 100%. As such peaks may be misinterpreted as new physics, their generation is investigated, both analytically and experimentally, for various detector configurations, including those used in searches for the spontaneous decay of the vacuum in heavy-ion collisions.

  2. The 1987 Whittier Narrows, California, earthquake: A Metropolitan shock

    OpenAIRE

    Hauksson, Egill; Stein, Ross S.

    1989-01-01

    Just 3 hours after the Whittier Narrows earthquake struck, it became clear that a heretofore unseen geological structure was seismically active beneath metropolitan Los Angeles. Contrary to initial expectations of strike-slip or oblique-slip motion on the Whittier fault, whose north end abuts the aftershock zone, the focal mechanism of the mainshock showed pure thrust faulting on a deep gently inclined surface [Hauksson et al., 1988]. This collection of nine research reports spans the spectru...

  3. Analysis of ultra-narrow ferromagnetic domain walls

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, Catherine; Paul, David

    2012-01-10

    New materials with high magnetic anisotropy will have domains separated by ultra-narrow ferromagnetic walls with widths on the order of a few unit cells, approaching the limit where the elastic continuum approximation often used in micromagnetic simulations is accurate. The limits of this approximation are explored, and the static and dynamic interactions with intrinsic crystalline defects and external driving elds are modeled. The results developed here will be important when considering the stability of ultra-high-density storage media.

  4. Three-Prong Distribution of Massive Narrow QCD Jets

    CERN Document Server

    Field, Matan; Kosower, David A; Mannelli, Lorenzo; Perez, Gilad

    2013-01-01

    We study the planar-flow distributions of narrow, highly boosted, massive QCD jets. Using the factorization properties of QCD in the collinear limit, we compute the planar-flow jet function from the one-to-three splitting function at tree-level. We derive the leading-log behavior of the jet function analytically. We also compare our semi-analytic jet function with parton-shower predictions using various generators.

  5. Narrowing of the Coronary Sinus: A Device-Based Therapy for Persistent Angina Pectoris.

    Science.gov (United States)

    Konigstein, Maayan; Verheye, Stefan; Jolicœur, E Marc; Banai, Shmuel

    2016-01-01

    Alongside the remarkable advances in medical and invasive therapies for the treatment of ischemic heart disease, an increasing number of patients with advanced coronary artery disease unsuitable for revascularization continue to suffer from angina pectoris despite optimal medical therapy. Patients with chronic angina have poor quality of life and increased levels of anxiety and depression. A considerable number of innovative therapeutic modalities for the treatment of chronic angina have been investigated over the years; however, none of these therapeutic options has become a standard of care, and none are widely utilized. Current treatment options for refractory angina focus on medical therapy and secondary risk factor modification. Interventions to create increased pressure in the coronary sinus may alleviate myocardial ischemia by forcing redistribution of coronary blood flow from the less ischemic subepicardium to the more ischemic subendocardium, thus relieving symptoms of ischemia. Percutaneous, transvenous implantation of a balloon expandable, hourglass-shaped, stainless steel mesh in the coronary sinus to create a fixed focal narrowing and to increase backwards pressure, may serve as a new device-based therapy destined for the treatment of refractory angina pectoris.

  6. Does platform switching really prevent crestal bone loss around implants?

    Directory of Open Access Journals (Sweden)

    Yoshiyuki Hagiwara

    2010-08-01

    Full Text Available To maintain long-term implant stability, it is important to minimize bone loss around the implant. Several clinical studies have shown a mean marginal bone loss around dental implants of 1.5–2 mm in the first year after prosthetic restoration. Currently, concepts to prevent bone loss around dental implants have been reported as the platform switching (PLS. This technique use of prosthetic abutments with reduced width in relation to the implant platform diameter seems to have the greatest potential to limit the crestal resorption. However, there are only a few reports on the mechanism of action or the extent of bone loss prevention, and as such, it is difficult to say that the effect of PLS has been thoroughly examined. Excluding case reports, articles on PLS can be broadly categorized into: (1 radiographic evaluation of crestal bone level in humans, (2 histological and histomorphometrical analysis in animals, or (3 finite element analysis. This review revealed a shortage of published data for above three categories related PLS. Researchers have attempted to explain the mechanism of action of PLS; however, it is necessary to conduct further studies, including histological studies using animals, to clarify the mechanism fully.

  7. Present status of heat transfer in narrow gap rectangular channel

    International Nuclear Information System (INIS)

    Sudo, Yukio; Kaminaga, Masanori

    1990-01-01

    In the safety evaluation for research nuclear reactors, at the time of abnormal transient change and accidents, after the tripping of a primary coolant pump, such event that the flow direction of coolant in a core reverses from steady downward flow to rising flow is supposed. In this case, the coexisting convection field, in which free convection and forced convection coexist, arises in place of forced convection, and especially in the research reactors using plate type fuel like JRR-3, it is important to grasp the heat transfer characteristics in the coexisting convection field in a narrow channel. Jackson et al. proposed the heat transfer correlation equation which can be applied to wide conditions including the coexisting convection zone, but its applicability to a narrow channel has not been confirmed. Based on the experimental results, in this study, the effect that the decrease of gap exerts to the convection heat transfer characteristics reported so far was investigated. The experiment and the results are reported. In this experiment on the coexisting convection zone in a narrow gap, the effect of main flow acceleration arose sufficiently large as compared with the effect of buoyancy, and heat transfer was promoted. (K.I.)

  8. Electron correlations in narrow energy bands: modified polar model approach

    Directory of Open Access Journals (Sweden)

    L. Didukh

    2008-09-01

    Full Text Available The electron correlations in narrow energy bands are examined within the framework of the modified form of polar model. This model permits to analyze the effect of strong Coulomb correlation, inter-atomic exchange and correlated hopping of electrons and explain some peculiarities of the properties of narrow-band materials, namely the metal-insulator transition with an increase of temperature, nonlinear concentration dependence of Curie temperature and peculiarities of transport properties of electronic subsystem. Using a variant of generalized Hartree-Fock approximation, the single-electron Green's function and quasi-particle energy spectrum of the model are calculated. Metal-insulator transition with the change of temperature is investigated in a system with correlated hopping. Processes of ferromagnetic ordering stabilization in the system with various forms of electronic DOS are studied. The static conductivity and effective spin-dependent masses of current carriers are calculated as a function of electron concentration at various DOS forms. The correlated hopping is shown to cause the electron-hole asymmetry of transport and ferromagnetic properties of narrow band materials.

  9. Heavy drinking, impulsivity and attentional narrowing following alcohol cue exposure.

    Science.gov (United States)

    Hicks, Joshua A; Fields, Sherecce; Davis, William E; Gable, Philip A

    2015-08-01

    Research shows that alcohol-related stimuli have the propensity to capture attention among individuals motivated to consume alcohol. Research has further demonstrated that impulsive individuals are especially prone to this type of attentional bias. Recently, it is suggested that alcohol cue exposure can also produce a general narrowing of attention consistent with the activation of approach motivational states. Based on previous models of addiction and recent research on the activation of approach motivational states, we predicted that impulsive individuals would demonstrate a constriction of attentional focus in response to alcohol cue exposure. Participants (n = 392) completed a task assessing attentional breadth in response to alcohol and non-alcohol cues, followed by measures of alcohol use and impulsivity. The findings revealed that impulsivity scores predicted narrowing of attentional scope following the presentation of alcohol cues for heavier drinkers but not for light drinkers. These results suggest that impulsive individuals who drink more heavily demonstrate a narrowing of attention in the presence of alcohol-related incentive cues. Implications for how these findings might account for the link between impulsivity and alcohol use and misuse are discussed.

  10. Experimental study on occupant evacuation in narrow seat aisle

    Science.gov (United States)

    Huang, Shenshi; Lu, Shouxiang; Lo, Siuming; Li, Changhai; Guo, Yafei

    2018-07-01

    Narrow seat aisle is an important area in the train car interior due to the large passenger population, however evacuation therein has not gained enough concerns. In this experimental study, the occupant evacuation of the narrow seat aisle area is investigated, with the aisle width of 0.4-0.6 m and the evacuation direction of forward and backward. The evacuation behaviors are analyzed based on the video record, and the discussion is carried out in the aspect of evacuation time, crowdedness, evacuation order, and aisle conflicts. The result shows that with the increasing aisle width, total evacuation time and the average specific evacuation rate decrease. The aisle is crowded for some time, with a large linear occupant densities. The evacuation order of each occupant is mainly related to the seat position. Moreover, it is found that the aisle conflicts can be well described by Burstedde's model. This study gives a useful benchmark for evacuation simulation of narrow seat aisle, and provides reference to safety design of seat area in train cars.

  11. Laser linewidth narrowing using transient spectral hole burning

    Energy Technology Data Exchange (ETDEWEB)

    Thiel, Charles W.; Cone, Rufus L. [Department of Physics, Montana State University, Bozeman, MT 59715 (United States); Böttger, Thomas, E-mail: tbottger@usfca.edu [Department of Physics and Astronomy, 2130 Fulton Street, University of San Francisco, San Francisco, CA 94117 (United States)

    2014-08-01

    We demonstrate significant narrowing of laser linewidths by high optical density materials with inhomogeneously broadened absorption. As a laser propagates through the material, the nonlinear spectral hole burning process causes a progressive self-filtering of the laser spectrum, potentially reaching values less than the homogeneous linewidth. The transient spectral hole dynamically adjusts itself to the instantaneous frequency of the laser, passively suppressing laser phase noise and side modes over the entire material absorption bandwidth without the need for electronic or optical feedback to the laser. Wide bandwidth laser phase noise suppression was demonstrated using Er{sup 3+} doped Y{sub 2}SiO{sub 5} and LiNbO{sub 3} at 1.5 μm by employing time-delayed self-heterodyne detection of an external cavity diode laser to study the spectral narrowing effect. Our method is not restricted to any particular wavelength or laser system and is attractive for a range of applications where ultra-low phase noise sources are required. - Highlights: • We demonstrate significant laser linewidths narrowing by high optical density materials. • Nonlinear spectral hole burning causes progressive self-filtering of laser spectrum. • Filter dynamically adjusts itself to the instantaneous frequency of the laser. • Demonstrated at 1.5 μm in Er{sup 3+} doped Y{sub 2}SiO{sub 5} and LiNbO{sub 3}. • Linewidth filtering is not restricted to any particular wavelength or laser system.

  12. Novel structural flexibility identification in narrow frequency bands

    International Nuclear Information System (INIS)

    Zhang, J; Moon, F L

    2012-01-01

    A ‘Sub-PolyMAX’ method is proposed in this paper not only for estimating modal parameters, but also for identifying structural flexibility by processing the impact test data in narrow frequency bands. The traditional PolyMAX method obtains denominator polynomial coefficients by minimizing the least square (LS) errors of frequency response function (FRF) estimates over the whole frequency range, but FRF peaks in different structural modes may have different levels of magnitude, which leads to the modal parameters identified for the modes with small FRF peaks being inaccurate. In contrast, the proposed Sub-PolyMAX method implements the LS solver in each subspace of the whole frequency range separately; thus the results identified from a narrow frequency band are not affected by FRF data in other frequency bands. In performing structural identification in narrow frequency bands, not in the whole frequency space, the proposed method has the following merits: (1) it produces accurate modal parameters, even for the modes with very small FRF peaks; (2) it significantly reduces computation cost by reducing the number of frequency lines and the model order in each LS implementation; (3) it accurately identifies structural flexibility from impact test data, from which structural deflection under any static load can be predicted. Numerical and laboratory examples are investigated to verify the effectiveness of the proposed method. (paper)

  13. Joint Space Narrowing in Patients With Pisotriquetral Osteoarthritis.

    Science.gov (United States)

    Ten Berg, Paul W L; Heeg, Erik; Strackee, Simon D; Streekstra, Geert J

    2017-09-01

    Patients with suspected pisotriquetral osteoarthritis may show joint space narrowing. However, the extent of joint space narrowing and its deviation from the joint space width (JSW) in normal anatomy is unknown. In this pathoanatomic study, we therefore compared the JSW in the pisotriquetral joint between osteoarthritic patient wrists and healthy wrists. We reviewed preoperative computed tomography (CT) scans of 8 wrists of patients with ulnar-sided wrist pain who underwent a pisiformectomy with confirmed pisotriquetral osteoarthritis at surgery. We also reviewed CT scans of 20 normal wrists from healthy volunteers serving as control group. Three-dimensional CT models of the pisiform and triquetrum were obtained from both affected and normal wrists, after which the minimum JSW was calculated in an automated fashion. In the patient group, the median (interquartile range) of the minimum JSW was 0.1 mm (0.0-0.2), and in the control group, 0.8 mm (0.3-0.9) ( P = .007). We showed that the pisotriquetral joint space in osteoarthritic patient wrists was significantly narrowed compared with healthy wrists. These results suggest that JSW evaluation has a potential diagnostic value in the work-up of patients with suspected pisotriquetral osteoarthritis. This is an interesting area for future clinical research, especially because no gold standard for diagnosing pisotriquetral osteoarthritis has been established yet.

  14. High prevalence of narrow angles among Filipino-American patients.

    Science.gov (United States)

    Seider, Michael I; Sáles, Christopher S; Lee, Roland Y; Agadzi, Anthony K; Porco, Travis C; Weinreb, Robert N; Lin, Shan C

    2011-03-01

    To determine the prevalence of gonioscopically narrow anterior chamber angles in a Filipino-American clinic population. The records of 122 consecutive, new, self-declared Filipino-American patients examined in a comprehensive ophthalmology clinic in Vallejo, California were reviewed retrospectively. After exclusion, 222 eyes from 112 patients remained for analysis. Data were collected for anterior chamber angle grade as determined by gonioscopy (Shaffer system), age, sex, manifest refraction (spherical equivalent), intraocular pressure, and cup-to-disk ratio. Data from both eyes of patients were included and modeled using standard linear mixed-effects regression. As a comparison, data were also collected from a group of 30 consecutive White patients from the same clinic. After exclusion, 50 eyes from 25 White patients remained for comparison. At least 1 eye of 24% of Filipino-American patients had a narrow anterior chamber angle (Shaffer grade ≤ 2). Filipino-American angle grade significantly decreased with increasingly hyperopic refraction (P=0.007) and larger cup-to-disk ratio (P=0.038). Filipino-American women had significantly decreased angle grades compared with men (P=0.028), but angle grade did not vary by intraocular pressure or age (all, P≥ 0.059). Narrow anterior chamber angles are highly prevalent in Filipino-American patients in our clinic population.

  15. Experimental and numerical investigation of heat transfer from a narrow annulus to supercritical pressure water

    International Nuclear Information System (INIS)

    Wang, Han; Bi, Qincheng; Yang, Zhendong; Wang, Linchuan

    2015-01-01

    Highlights: • Heat transfer of supercritical water in a narrow annulus is investigated. • Effects of system parameters and flow direction on heat transfer are studied. • Deteriorated heat transfer is analyzed both experimentally and numerically. - Abstract: Heat transfer characteristics of supercritical pressure water in a narrow annulus with vertically upward and downward flows were investigated experimentally and numerically. The outer diameter of the inner heated rod is 8 mm with an effective heated length of 620 mm. Experimental parameters covered the pressure of 23–28 MPa, mass flux of 400–1000 kg/m 2 s and heat flux on the outer surface of the heated rod from 200 to 1000 kW/m 2 . The general heat transfer behaviors were discussed with respect to various mass fluxes and pressures. According to the experimental data, it was found that the effect of flow direction on heat transfer depends on the heat-flux to mass-flux ratio (q/G). Heat transfer is much improved in the downward flow compared to that of upward flow at high q/G ratios. At the pressure of 25 MPa, low-mass-flux deteriorated heat transfer occurred in the upward flow but not in the downward flow. At the same test parameters, however, heat transfer deterioration was observed at both of the two flow directions when the pressure was lowered to 23 MPa. The experimental results indicate that buoyancy plays an important role for this type of deterioration, but is not the only mechanism that leads to the heat transfer deterioration. Three turbulence models were assessed against the annulus test data, it was found that the SST k-ω model gives a satisfying prediction of heat transfer deterioration especially for the case of downward flow. The mechanisms for the low-mass-flow heat transfer deterioration were investigated from the viewpoints of buoyancy and property variations of the supercritical water

  16. Forced convective boiling heat transfer of water in vertical rectangular narrow channel

    International Nuclear Information System (INIS)

    Chen, Chong; Gao, Pu-zhen; Tan, Si-chao; Chen, Han-ying; Chen, Xian-bing

    2015-01-01

    Highlights: • Chen correlation cannot well predict the coefficient of rectangular channel. • Kim and Mudawar correlation is the best one among the Chen type correlations. • Lazarek and Black correlation predicted 7.0% of data within the ±30% error band. • The new correlation can well predict the coefficient with a small MAE of 14.4%. - Abstract: In order to research the characteristics of boiling flows in a vertical rectangular narrow channel, a series of convective boiling heat transfer experiments are performed. The test section is made of stainless steel with an inner diameter of 2 × 40 mm and heated length of 1100 mm. The 3194 experimental data points are obtained for a heat flux range of 10–700 kW/m 2 , a mass flux range of 200–2400 kg/m 2 s, a system pressure range of 0.1–2.5 MPa, and a quality range of 0–0.8. Eighteen prediction models are used to predict the flow boiling heat transfer coefficient of the rectangular narrow channel and the predicted value is compared against the database including 3194 data points, the results show that Chen type correlations and Lazarek and Black type correlations are not suitable for the rectangular channel very much. The Kim and Mudawar correlation is the best one among the 18 models. A new correlation is developed based on the superposition concept of nucleate boiling and convective boiling. the new correlation is shown to provide a good prediction against the database, evidenced by an overall MAE of 14.4%, with 95.2% and 98.6% of the data falling within ±30% and ±35% error bands, respectively

  17. The effect of induction motor shaft diameter on motor performance

    Directory of Open Access Journals (Sweden)

    Asım Gökhan Yetgin

    2017-10-01

    Full Text Available Induction motors are used in many areas from the past to the present and in different fields with the development of technology has continued to be used. It is obvious that induction motors as an improvement to the efficiency in terms of energy saving would cause great benefit. In that context, induction motor manufacturers and designers are constantly trying out new methods to improve motor performance and efficiency. In this study, what would be the optimum diameter of the shaft in order to increase the efficiency of the induction motor were investigated. In the study, 5.5 kW, 7.5 kW and 11 kW motors analyzes were also performed. Obtained shaft diameter values were compared with the manufacturer values. In addition, critical points such as the magnetic flux values, weight values and performances of the motors were examined and optimal shaft diameter values for each motor have been determined.

  18. NEOWISE REACTIVATION MISSION YEAR TWO: ASTEROID DIAMETERS AND ALBEDOS

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, C. R.; Cutri, R. M. [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Mainzer, A.; Bauer, J.; Kramer, E. A.; Masiero, J.; Sonnett, S. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Grav, T. [Planetary Science Institute, Tucson, AZ (United States); Wright, E. L., E-mail: cnugent@ipac.caltech.edu [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States)

    2016-09-01

    The Near-Earth Object Wide-Field Infrared Survey Explorer (NEOWISE) mission continues to detect, track, and characterize minor planets. We present diameters and albedos calculated from observations taken during the second year since the spacecraft was reactivated in late 2013. These include 207 near-Earth asteroids (NEAs) and 8885 other asteroids. Of the NEAs, 84% NEAs did not have previously measured diameters and albedos by the NEOWISE mission. Comparison of sizes and albedos calculated from NEOWISE measurements with those measured by occultations, spacecraft, and radar-derived shapes shows accuracy consistent with previous NEOWISE publications. Diameters and albedos fall within ±∼20% and ±∼40%, 1-sigma, respectively, of those measured by these alternate techniques. NEOWISE continues to preferentially discover near-Earth objects which are large (>100 m), and have low albedos.

  19. Divergent biparietal diameter growth rates in twin pregnancies.

    Science.gov (United States)

    Houlton, M C

    1977-05-01

    Twenty-eight twin pregnancies were monitored by serial ultrasonic cephalometry from 30 or 31 weeks' gestation. The rates of growth of the individual twins as determined by biparietal diameters were similar in 11 cases (39%) and divergent in 17 (61%). When the rates of growth were divergent, the lesser rate was always below the mean for singleton pregnancies, and the incidence of small-for-gestational-age babies was 18 of 34 (53%). It was apparent that the greater the difference in biparietal diameters within the 2 weeks preceding delivery, the higher the risk of a small-for-gestation-age baby being delivered. No comment could be made on the growth rate prior to 28 weeks except that at diagnosis there was little or no difference in biparietal diameters.

  20. Bubble behaviour and mean diameter in subcooled flow boiling

    Energy Technology Data Exchange (ETDEWEB)

    Zeitoun, O.; Shoukri, M. [McMaster Univ., Hamilton, Ontario (Canada)

    1995-09-01

    Bubble behaviour and mean bubble diameter in subcooled upward flow boiling in a vertical annular channel were investigated under low pressure and mass flux conditions. A high speed video system was used to visualize the subcooled flow boiling phenomenon. The high speed photographic results indicated that, contrary to the common understanding, bubbles tend to detach from the heating surface upstream of the net vapour generation point. Digital image processing technique was used to measure the mean bubble diameter along the subcooled flow boiling region. Data on the axial area-averaged void fraction distributions were also obtained using a single beam gamma densitometer. Effects of the liquid subcooling, applied heat flux and mass flux on the mean bubble size were investigated. A correlation for the mean bubble diameter as a function of the local subcooling, heat flux and mass flux was obtained.

  1. On the diameter of dot-critical graphs

    Directory of Open Access Journals (Sweden)

    Doost Ali Mojdeh

    2009-01-01

    Full Text Available A graph G is \\(k\\-dot-critical (totaly \\(k\\-dot-critical if \\(G\\ is dot-critical (totaly dot-critical and the domination number is \\(k\\. In the paper [T. Burtona, D. P. Sumner, Domination dot-critical graphs, Discrete Math, 306 (2006, 11-18] the following question is posed: What are the best bounds for the diameter of a \\(k\\-dot-critical graph and a totally \\(k\\-dot-critical graph \\(G\\ with no critical vertices for \\(k \\geq 4\\? We find the best bound for the diameter of a \\(k\\-dot-critical graph, where \\(k \\in\\{4,5,6\\}\\ and we give a family of \\(k\\-dot-critical graphs (with no critical vertices with sharp diameter \\(2k-3\\ for even \\(k \\geq 4\\.

  2. Measurements of the diameter of the supernova SN 1987A

    International Nuclear Information System (INIS)

    Karovska, M.; Nisenson, P.; Standley, C.; Heathcote, S.R.

    1991-01-01

    Speckle interferometric measurements of the angular diameter of SN 1987A in the Large Magellanic Cloud, obtained at 664 days after the outburst are presented. Diameters were estimated with milliarcsec precision at 657 nm and 550 nm by fitting model visibility functions to the data corresponding to different intensity distributions for the supernova disk. Measurements made assuming a uniform intensity distribution were compared to the uniform disk measurements obtained from 30 days after the explosion. Diameter measurements obtained near the center of the H-alpha line are consistent with homologous expansion of the supernova shell with a mean velocity of 2850 km/s. The linear least-squares fit to the measurements obtained at other wavelengths from 260 days after the explosion yielded a somewhat lower mean expansion velocity. 8 refs

  3. Characteristics of two-phase flows in large diameter channels

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, J.P., E-mail: schlegelj@mst.edu [Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, 301 W 14th St., Rolla, MO 65401 (United States); Hibiki, T.; Ishii, M. [School of Nuclear Engineering, Purdue University, 400 Central Dr., West Lafayette, IN 47907 (United States)

    2016-12-15

    Two-phase flows in large diameter channels have a great deal of importance in a wide variety of industrial applications. Nuclear systems, petroleum refineries, and chemical processes make extensive use of larger systems. Flows in such channels have very different properties from flows in smaller channels which are typically used in experimental research. In this paper, the various differences between flows in large and small channels are highlighted using the results of previous experimental and analytical research. This review is followed by a review of recent experiments in and model development for flows in large diameter channels performed by the authors. The topics of these research efforts range from void fraction and interfacial area concentration measurement to flow regime identification and modeling, drift-flux modeling for high void fraction conditions, and evaluation of interfacial area transport models for large diameter channels.

  4. Comparison of mechanical and biological properties of zirconia and titanium alloy orthodontic micro-implants.

    Science.gov (United States)

    Choi, Hae Won; Park, Young Seok; Chung, Shin Hye; Jung, Min Ho; Moon, Won; Rhee, Sang Hoon

    2017-07-01

    The aim of this study was to compare the initial stability as insertion and removal torque and the clinical applicability of novel orthodontic zirconia micro-implants made using a powder injection molding (PIM) technique with those parameters in conventional titanium micro-implants. Sixty zirconia and 60 titanium micro-implants of similar design (diameter, 1.6 mm; length, 8.0 mm) were inserted perpendicularly in solid polyurethane foam with varying densities of 20 pounds per cubic foot (pcf), 30 pcf, and 40 pcf. Primary stability was measured as maximum insertion torque (MIT) and maximum removal torque (MRT). To investigate clinical applicability, compressive and tensile forces were recorded at 0.01, 0.02, and 0.03 mm displacement of the implants at angles of 0°, 10°, 20°, 30°, and 40°. The biocompatibility of zirconia micro-implants was assessed via an experimental animal study. There were no statistically significant differences between zirconia micro-implants and titanium alloy implants with regard to MIT, MRT, or the amount of movement in the angulated lateral displacement test. As angulation increased, the mean compressive and tensile forces required to displace both types of micro-implants increased substantially at all distances. The average bone-to-implant contact ratio of prototype zirconia micro-implants was 56.88 ± 6.72%. Zirconia micro-implants showed initial stability and clinical applicability for diverse orthodontic treatments comparable to that of titanium micro-implants under compressive and tensile forces.

  5. Long-term retrospective study of implants placed after sinus floor augmentation with fresh-frozen homologous block

    Directory of Open Access Journals (Sweden)

    Livingstom Rubens Sousa Rocha

    2017-01-01

    Full Text Available Aim: The aim of this study was to analyze and follow-up implants placed in the posterior maxillary regions previously grafted with homologous bone. Materials and Methods: Forty-one grafts with homologous bone blocks were performed in maxillary sinuses, and 121 implants were placed in premolar and molar regions approximately 6 months after the grafts. Patients were followed up for periods varying from 12 to 124 months after rehabilitation. Results: The results showed two implant failures, for a 98.3% success rate during the follow-up period. Discussion: The implants placed had an average torque of 40 N-cm, regardless of the, design, diameter, and length of the implants used. Conclusion: After following up on the implants placed in this study, we concluded that those placed in regions of the maxillary sinuses previously grafted with homologous bone blocks had high long-term success rates and met the functional masticatory requirements.

  6. US Intergroup Anal Carcinoma Trial: Tumor Diameter Predicts for Colostomy

    Science.gov (United States)

    Ajani, Jaffer A.; Winter, Kathryn A.; Gunderson, Leonard L.; Pedersen, John; Benson, Al B.; Thomas, Charles R.; Mayer, Robert J.; Haddock, Michael G.; Rich, Tyvin A.; Willett, Christopher G.

    2009-01-01

    Purpose The US Gastrointestinal Intergroup Radiation Therapy Oncology Group 98-11 anal carcinoma trial showed that cisplatin-based concurrent chemoradiotherapy resulted in a significantly higher rate of colostomy compared with mitomycin-based therapy. Established prognostic variables for patients with anal carcinoma include tumor diameter, clinical nodal status, and sex, but pretreatment variables that would predict the likelihood of colostomy are unknown. Methods A secondary analysis was performed by combining patients in the two treatment arms to evaluate whether new predictive and prognostic variables would emerge. Univariate and multivariate analyses were carried out to correlate overall survival (OS), disease-free survival, and time to colostomy (TTC) with pretreatment and treatment variables. Results Of 682 patients enrolled, 644 patients were assessable and analyzed. In the multivariate analysis, tumor-related prognosticators for poorer OS included node-positive cancer (P ≤ .0001), large (> 5 cm) tumor diameter (P = .01), and male sex (P = .016). In the treatment-related categories, cisplatin-based therapy was statistically significantly associated with a higher rate of colostomy (P = .03) than was mitomycin-based therapy. In the pretreatment variables category, only large tumor diameter independently predicted for TTC (P = .008). Similarly, the cumulative 5-year colostomy rate was statistically significantly higher for large tumor diameter than for small tumor diameter (Gray's test; P = .0074). Clinical nodal status and sex were not predictive of TTC. Conclusion The combined analysis of the two arms of RTOG 98-11, representing the largest prospective database, reveals that tumor diameter (irrespective of the nodal status) is the only independent pretreatment variable that predicts TTC and 5-year colostomy rate in patients with anal carcinoma. PMID:19139424

  7. Determination of the Tapping Part Diameter of the Thread Mill

    Directory of Open Access Journals (Sweden)

    A. E. Dreval'

    2015-01-01

    Full Text Available Currently, there is a tendency to increase the proportion of thread milling operations, among other ways of tapping, which is associated with increasing number of CNC machines, flexibility and versatility of the process.Developments presently existing in the RF and used in the thread mills deal, mainly, with the thread milling cutter designs, to process internal and external thread with straight flutes made from high-speed steel.The paper presents a technique to calculate and select the initial design parameters, i.e. the external diameter of the tapping part of thread milling cutter, which is chosen as a basic computational design. The analysis of directories of tool companies containing foreign de-signs of solid thread end-milling cutters has shown that most of them rep-resent the thread cutter designs made of solid carbide. There are solid and interlocking side milling cutters, which use a tapping part both as a single-disk and as a multi-disk one; chip flutes are made to be both as direct and as screw; solid designs of cutters are made from carbide with a diameter of up to 20 ... 25 mm; thread cutters can be left- and right-hand cutting; Designs of the combined thread mills are proposed; internal channels are used for coolant supply.It is shown that the purpose of the external diameter of the tapping part of the thread mill should take into account the effect of the thread mill diameter on the milling process performance, precision of thread profile received, taper thread, tool strength, and the volume of flutes.The analysis has shown that when choosing the external diameter of the thread mill it worth taking its maximum diameter to improve the char-acteristics of the process under the restrictions imposed on the accuracy of the formed thread.

  8. The significance of a correlation of blister diameter with skin thickness for Ni and Be for blistering models

    International Nuclear Information System (INIS)

    Das, S.K.; Kaminsky, M.; Fenske, G.

    1978-01-01

    It has been suggested that large lateral stresses introduced in an ion implanted surface layer may cause elastic instability and buckling of the implant layer (blister formation), and result in a relationship Dsub(mp) proportional to tsup(3/2) between the most probable blister diameter Dsub(mp) and the blister skin thickness, t, for metals such as Be, V, stainless steel, Nb and Mo. To test this relationship a systematic study of the correlation between blister diameter and skin thickness for helium blistering of annealed polycrystalline Ni and Be has been conducted for helium ion energies in the range of 15-300 keV. For beryllium the relationship between Dsup(mp) (μm) and t(μm) can be fitted by the expression Dsub(mp)=24.6tsup(1.25) whereas for nickel a best fit is obtained for the expression Dsub(mp)=1.24tsup(1.5). These results, together with earlier results for Nb and V show that the relationship between Dsub(mp) and t is stronly dependent on the type of metal studied and do not support the lateral stress model for blister formation. (Auth.)

  9. Residual stresses and critical diameter in vitreous matrix materials

    International Nuclear Information System (INIS)

    Mastelaro, Valmor R.; Zanotto, Edgar D.

    1995-01-01

    The present study was undertaken to test the validity of existing models for: i) the residual internal stresses which arise due to thermal and elastic mismatch in duplex systems, and ii) the critical particle diameter for spontaneous cracking. Partially crystallized 1,07 Na 2 O-2 Ca O-3 Si O 2 - 6% P 2 O 5 glasses were studied. The experimental residual stress was in excellent agreement with the calculated value, however, the critical particle diameter, estimated by an energy balance approach, was more than ten times smaller than the experimental value. This discrepancy indicates that the energy model is not applicable in this case. (author)

  10. NEOWISE REACTIVATION MISSION YEAR ONE: PRELIMINARY ASTEROID DIAMETERS AND ALBEDOS

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, C. R.; Cutri, R. M. [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Mainzer, A.; Masiero, J.; Bauer, J.; Kramer, E.; Sonnett, S.; Stevenson, R. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Grav, T. [Planetary Science Institute, Tucson, AZ (United States); Wright, E. L., E-mail: cnugent@ipac.caltech.edu [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States)

    2015-12-01

    We present preliminary diameters and albedos for 7956 asteroids detected in the first year of the NEOWISE Reactivation mission. Of those, 201 are near-Earth asteroids and 7755 are Main Belt or Mars-crossing asteroids. 17% of these objects have not been previously characterized using the Near-Earth Object Wide-field Infrared Survey Explorer, or “NEOWISE” thermal measurements. Diameters are determined to an accuracy of ∼20% or better. If good-quality H magnitudes are available, albedos can be determined to within ∼40% or better.

  11. Determination of Aerosol Particle Diameter Using Cascade Impactor Procedure

    International Nuclear Information System (INIS)

    Bunawas; Ruslanto, P. O

    1998-01-01

    Determination of aerosol particle size distribution has been done using a low pressure Andersen's cascade impactor with 13 stages. The aerosol has been sampled with flow rate of aerosol sampling of 28.3 Ipm. Preliminary study result shows that aerosol in the simulation chamber was spread in monomodal distribution with Mass Median Aerodynamic Diameter of 4.9 μm. The aerosol measurement in Japan Power Demonstration Reactor has been spread in trimodal distribution with Activity Median Aerodynamic Diameter equal to 13.3 μm. The use of mylar as impaction plate instead of aluminum foil gives good result

  12. Evaluation of primary and secondary stability of titanium implants using different surgical techniques.

    Science.gov (United States)

    Tabassum, Afsheen; Meijer, Gert J; Walboomers, X Frank; Jansen, John A

    2014-04-01

    To investigate the influence of different surgical techniques on the primary and secondary implant stability using trabecular bone of goats as an implantation model. In the iliac crest of eight goats, 48 cylindrical-screw-type implants with a diameter of 4.2 mm (Dyna(®) ; Bergen op Zoom, the Netherlands) were installed, using three different surgical techniques: (i) 5% undersized, using a final drill diameter of 4 mm; (ii) 15% undersized, using a final drill diameter of 3.6 mm; and (iii) 25% undersized, using a final drill diameter of 3.2 mm. Peak insertion torque values were measured by a Digital(®) (MARK-10 Corporation, New York, NY, USA) torque gauge instrument during placement. At 3 weeks after implantation, removal torque was measured. Histomorphometrically, the peri-implant bone volume was measured in three zones; the inner zone (0-500 μm), the middle zone (500-1000 μm) and the outer zone (1000-1500 μm). Evaluation of the obtained data demonstrated no statistically significant difference between different surgical techniques regarding removal torque values. With respect to the percentage peri-implant bone volume (%BV), also no significant difference could be observed between all three applied surgical techniques for both the inner, middle and outer zone. However, irrespective of the surgical technique, it was noticed that the %BV was significantly higher for the inner zone as compared to middle and outer zone (P < 0.05) around the implant. At 3 weeks after implant installation, independent of the used undersized surgical technique, the %BV in the inner zone (0-500 μm) peri-implant area was improved due to both condensation of the surrounding bone as also the translocation of host bone particles along the implant surface. Surprisingly, no mechanical beneficial effect of the 25% undersized surgical technique could be observed as compared to the 5% or 15% undersized surgical technique to improve primary or secondary implant stability. © 2013

  13. Fracture Resistance and Mode of Failure of Ceramic versus Titanium Implant Abutments and Single Implant-Supported Restorations.

    Science.gov (United States)

    Sghaireen, Mohd G

    2015-06-01

    The material of choice for implant-supported restorations is affected by esthetic requirements and type of abutment. This study compares the fracture resistance of different types of implant abutments and implant-supported restorations and their mode of failure. Forty-five Oraltronics Pitt-Easy implants (Oraltronics Dental Implant Technology GmbH, Bremen, Germany) (4 mm diameter, 10 mm length) were embedded in clear autopolymerizing acrylic resin. The implants were randomly divided into three groups, A, B and C, of 15 implants each. In group A, titanium abutments and metal-ceramic crowns were used. In group B, zirconia ceramic abutments and In-Ceram Alumina crowns were used. In group C, zirconia ceramic abutments and IPS Empress Esthetic crowns were used. Specimens were tested to failure by applying load at 130° from horizontal plane using an Instron Universal Testing Machine. Subsequently, the mode of failure of each specimen was identified. Fracture resistance was significantly different between groups (p Empress crowns supported by zirconia abutments had the lowest fracture loads (p = .000). Fracture modes of metal-ceramic crowns supported by titanium abutments included screw fracture and screw bending. Fracture of both crown and abutment was the dominant mode of failure of In-Ceram/IPS Empress crowns supported by zirconia abutments. Metal-ceramic crowns supported by titanium abutments were more resistant to fracture than In-Ceram crowns supported by zirconia abutments, which in turn were more resistant to fracture than IPS Empress crowns supported by zirconia abutments. In addition, failure modes of restorations supported by zirconia abutments were more catastrophic than those for restorations supported by titanium abutments. © 2013 Wiley Periodicals, Inc.

  14. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  15. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne

    2012-01-01

    We evaluated the association between radiation therapy and severe capsular contracture or reoperation after 717 delayed breast implant reconstruction procedures (288 1- and 429 2-stage procedures) identified in the prospective database of the Danish Registry for Plastic Surgery of the Breast during...... of radiation therapy was associated with a non-significantly increased risk of reoperation after both 1-stage (HR = 1.4; 95% CI: 0.7-2.5) and 2-stage (HR = 1.6; 95% CI: 0.9-3.1) procedures. Reconstruction failure was highest (13.2%) in the 2-stage procedures with a history of radiation therapy. Breast...... reconstruction approaches other than implants should be seriously considered among women who have received radiation therapy....

  16. Piezosurgery in implant dentistry

    Science.gov (United States)

    Stübinger, Stefan; Stricker, Andres; Berg, Britt-Isabelle

    2015-01-01

    Piezosurgery, or the use of piezoelectric devices, is being applied increasingly in oral and maxillofacial surgery. The main advantages of this technique are precise and selective cuttings, the avoidance of thermal damage, and the preservation of soft-tissue structures. Through the application of piezoelectric surgery, implant-site preparation, bone grafting, sinus-floor elevation, edentulous ridge splitting or the lateralization of the inferior alveolar nerve are very technically feasible. This clinical overview gives a short summary of the current literature and outlines the advantages and disadvantages of piezoelectric bone surgery in implant dentistry. Overall, piezoelectric surgery is superior to other methods that utilize mechanical instruments. Handling of delicate or compromised hard- and soft-tissue conditions can be performed with less risk for the patient. With respect to current and future innovative surgical concepts, piezoelectric surgery offers a wide range of new possibilities to perform customized and minimally invasive osteotomies. PMID:26635486

  17. Ion implantation in metals

    International Nuclear Information System (INIS)

    Vook, F.L.

    1977-02-01

    The application of ion beams to metals is rapidly emerging as a promising area of research and technology. This report briefly describes some of the recent advances in the modification and study of the basic properties of metals by ion implantation techniques. Most of the research discussed illustrates some of the new and exciting applications of ion beams to metals which are under active investigation at Sandia Laboratories, Albuquerque

  18. Prediction and error of baldcypress stem volume from stump diameter

    Science.gov (United States)

    Bernard R. Parresol

    1998-01-01

    The need to estimate the volume of removals occurs for many reasons, such as in trespass cases, severance tax reports, and post-harvest assessments. A logarithmic model is presented for prediction of baldcypress total stem cubic foot volume using stump diameter as the independent variable. Because the error of prediction is as important as the volume estimate, the...

  19. Changes in intraocular pressure and horizontal pupil diameter ...

    African Journals Online (AJOL)

    The objective of this study was to determine the effects of topical 0.5% tropicamide, 1% atropine sulphate and 10% phenylephrine hydrochloride ophthalmic solutions on intraocular pressure (IOP) and horizontal pupil diameter (HPD) in the dog during the first hour after treatment. Forty clinically and ophthalmologically ...

  20. Study of tube diameter effect on the burnout

    International Nuclear Information System (INIS)

    Levitan, L.L.; Lantsman, F.P.; Dedneva, E.I.

    1981-01-01

    Effect of a tube diameter d on boundary steam content Xsub(b) is experimentally investigated during unwashed liquid wall film drying in the disperse-ring flow regime. For this purpose systematical experimental investigations of the burnout of the second kind in tubes with diameters of 4, 6 and 12 mm have been carried out as well as the other data relating to burnout in tubes with diameter from 4 to 40 mm are used. The investigations have been carried out at water and steam pressures of 4.9-13.7 MPa and mass velocities from 750 to 5000 kg/m 2 xs. It is elucidated that increase in the tube diameter results in reducing the ranges of pressures and mass velocities at which Xsub(b) is independent of heat flux. Quantity dependence Xsub(b)=f(d) has been obtained as well. The best agreement with data from different experiments is observed when taking into account the effect of d on Xsub(b) by means of the following relation: Xsub(b) is proportional to dsup(-0.25). In this case divergence, as a rule, does not exceed 10% [ru