WorldWideScience

Sample records for nanofilter design retains

  1. Nanofilter platform based on functionalized carbon nanotubes for adsorption and elimination of Acrolein, a toxicant in cigarette smoke

    Science.gov (United States)

    Yoosefian, Mehdi; Pakpour, Atef; Etminan, Nazanin

    2018-06-01

    This paper discusses the use of carboxylated single-walled carbon nanotube as a general nanofilter platform for the removal of acrolein carcinogen from cigarette smoke. The analyses carried out in the detailed study of the electronic and structural effects of the adsorption of acrolein onto COOH loaded on single-walled carbon nanotube under the density functional theory framework. The results of Bader theory of atoms in molecules, natural bond orbital, molecular potential electron surface and density of state confirm the potential application of the suggested nanofilter platform.

  2. Second-generation nanofiltered plasma-derived mannan-binding lectin product

    DEFF Research Database (Denmark)

    Laursen, I.; Houen, G.; Højrup, P.

    2007-01-01

    infections. Substitution therapy with plasma-derived MBL is a promising treatment of diseases associated with MBL deficiency. A first-generation MBL product has been shown to be safe and well tolerated, and patients have benefited from MBL treatment. Following is a description of the development...... of a nanofiltered second-generation MBL product from Cohn fraction III, with the use of a new affinity matrix for MBL purification and the characteristics of this improved product. MATERIALS AND METHODS: Carbohydrate-based gels were comparatively screened as affinity matrices. MBL was extracted from fraction III......, and affinity purified on a Superdex 200 pg column. The eluted material underwent two virus reduction steps: filtration through Planova 20N and solvent/detergent treatment. It was further purified by anion-exchange and gel-filtration chromatography. The affinity eluate and the final MBL fraction were...

  3. Reliability-based design of a retaining wall

    OpenAIRE

    Kim, John Sang

    1995-01-01

    A retaining wall is subject to various limit states such as sliding, overturning and bearing capacity, and it can fail by anyone of them. Since a great deal of uncertainty is involved in the analysis of the limit states~ the use of detenninistic conventional safety factors may produce a misleading result. The main objective of this study is to develop a procedure for the optimum design of a retaining wall by using the reliability theory. Typical gravity retaining walls with fou...

  4. Optimum Design of Gravity Retaining Walls Using Charged System Search Algorithm

    Directory of Open Access Journals (Sweden)

    S. Talatahari

    2012-01-01

    Full Text Available This study focuses on the optimum design retaining walls, as one of the familiar types of the retaining walls which may be constructed of stone masonry, unreinforced concrete, or reinforced concrete. The material cost is one of the major factors in the construction of gravity retaining walls therefore, minimizing the weight or volume of these systems can reduce the cost. To obtain an optimal seismic design of such structures, this paper proposes a method based on a novel meta-heuristic algorithm. The algorithm is inspired by the Coulomb's and Gauss’s laws of electrostatics in physics, and it is called charged system search (CSS. In order to evaluate the efficiency of this algorithm, an example is utilized. Comparing the results of the retaining wall designs obtained by the other methods illustrates a good performance of the CSS. In this paper, we used the Mononobe-Okabe method which is one of the pseudostatic approaches to determine the dynamic earth pressure.

  5. Functional design criteria for the retained gas sampler system

    International Nuclear Information System (INIS)

    Wootan, D.W.

    1995-01-01

    A Retained Gas Sampler System (RGSS) is being developed to capture and analyze waste samples from Hanford Flammable Gas Watch List Tanks to determine both the quantity and composition of gases retained in the waste. The RGSS consists of three main components: the Sampler, Extractor, and Extruder. This report describes the functional criteria for the design of the RGSS components. The RGSS Sampler is based on the WHC Universal Sampler design with modifications to eliminate gas leakage. The primary function of the Sampler is to capture a representative waste sample from a tank and transport the sample with minimal loss of gas content from the tank to the laboratory. The function of the Extruder is to transfer the waste sample from the Sampler to the Extractor. The function of the Extractor is to separate the gases from the liquids and solids, measure the relative volume of gas to determine the void fraction, and remove and analyze the gas constituents

  6. Summary report on the design of the retained gas sampler system (retained gas sampler, extruder and extractor)

    International Nuclear Information System (INIS)

    Wootan, D.W.; Bolden, R.C.; Bridges, A.E.; Cannon, N.S.; Chastain, S.A.; Hey, B.E.; Knight, R.C.; Linschooten, C.G.; Pitner, A.L.; Webb, B.J.

    1994-01-01

    This document summarizes work performs in Fiscal Year 1994 to develop the three main components of Retained Gas Sampler System (RGSS). These primary components are the Retained Gas Sampler (RGS), the Retained Gas Extruder (RGE), and the Retained Gas Extractor (RGEx). The RGS is based on the Westinghouse Hanford Company (WHC) Universal Sampler design, and includes modifications to reduce gas leakage. The primary data priorities for the RGSS are to measure the void fraction and the flammable gas concentration in the waste sample. Significant progress has been made in developing the RGSS. The RGSS is being developed by WHC to extract a representative waste sample from a Flammable Gas Watch List Tanks and to measure both the amount and composition of free and open-quotes boundclose quotes gases. Sudden releases of flammable gas mixtures are a safety concern for normal waste storage operations and eventual waste retrieval. Flow visualization testing was used to identify important fluid dynamic issues related to the sampling process. The primary data priorities for the RGSS are to measure the void fraction and the flammable gas concentration in the waste sample. The safety analysis for the RGSS is being performed by Los Alamos National Laboratory and is more than sixty percent (60%) complete

  7. Clear retainer

    Directory of Open Access Journals (Sweden)

    Priyakorn Chaimongkol

    2017-01-01

    Full Text Available A clear retainer is a removable retainer that is popular in the present day. Compared with conventional fixed and removable orthodontic retainers, it is a more esthetic, comfortable, and inexpensive appliance. Although several studies have been published about clear retainers, it could be difficult to interpret the results because of the variety of study designs, sample sizes, and research methods. This article is intended to compile the content from previous studies and discuss advantages, disadvantages, fabrication, insertion, and adjustment. Moreover, the effectiveness in maintaining dental position, occlusion, retention protocols, thickness, and survival rate of clear retainers is discussed.

  8. Changes in the transmission properties of multi-tooth plasmonic nano-filters (multi-TPNFs) caused by geometrical imperfection

    International Nuclear Information System (INIS)

    Khaksar, A; Fatemi, H

    2012-01-01

    To model the filtering behavior of a multi-tooth plasmonic nano-filter (multi-TPNF), an equivalent circuitry composed of a set of serried impedances is considered. The changes caused in its filtering behavior are proposed as a measuring tool to investigate the effect of the geometrical imperfections occurring during the manufacture of the device. Consequently, the effects of changes in the nominal size of each of the geometrical parameters of a multi-TPNF sample, such as its tooth height, d, its tooth width, w, and the separation between two successive teeth, Δ, on its transmittance are investigated. It is observed that each single tooth of the multi-TPNF and also the waveguide between any of its two successive teeth exhibit a very Fabry–Perot interferometer like behavior. The variation of the transmission spectra of a multi-TPNF whose geometrical parameters are imperfect is compared with the desired filter, and also the effect of the number of geometrically imperfect teeth of the multi-TPNF on the filtering spectra is examined. (paper)

  9. [Influence of retainer design on fixation strength of resin-bonded glass fiber reinforced composite fixed cantilever dentures].

    Science.gov (United States)

    Petrikas, O A; Voroshilin, Iu G; Petrikas, I V

    2013-01-01

    Fiber-reinforced composite (FRC) fixed partial dentures (FPD) have become an accepted part of the restorative dentist's armamentarium. The aim of this study was to evaluate in vitro the influence of retainer design on the strength of two-unit cantilever resin-bonded glass FRC-FPDs. Four retainer designs were tested: a dual wing, a dual wing + horizontal groove, a dual wing + occlusal rest and a step-box. Of each design on 7 human mandibular molars, FRC-FPDs of a premolar size were produced. The FRC framework was made of resin Revolution (Kerr) impregnated glass fibers (GlasSpan, GlasSpan) and veneered with hybrid resin composite (Charisma, Kulzer). Revolution (Kerr) was used as resin luting cement. FRC-FPDs were loaded to failure in a universal testing machine. T (Student's)-test was used to evaluate the data. The four designs were analyzed with finite element analysis (FEA) to reveal the stress distribution within the tooth/restoration complex. Significantly lower fracture strengths were observed with inlay-retained FPDs (step-box: 172±11 N) compared to wing-retained FPDs (poptimal design for replacement of a single premolar by means of a two-unit cantilever FRC-FPDs.

  10. Kansal′s Retainer: A Removable, Tooth-Borne Orthodontic Retainer

    Directory of Open Access Journals (Sweden)

    Sudhanshu Kansal

    2013-01-01

    Full Text Available Adequate retention of a finished orthodontic patient can be the difference between a successful or an unsuccessful treatment. The acrylic portion of the conventional Hawley′s appliance causes a reduced compliance in many orthodontic patients. In an attempt to overcome the drawbacks of the previously used orthodontic retainers a tooth-borne orthodontic retainer was designed, also called the ′Kansal′s retainer′ (Patent pending.

  11. Load Transfer Characteristics of Various Designs of Three-Implant-Retained Mandibular Overdentures.

    Science.gov (United States)

    Tokar, Emre; Uludag, Bulent

    2015-01-01

    Many different attachment systems (eg, bars, studs, magnets, telescopic copings) have been used to retain overdentures. The current study aimed to investigate the load transfer characteristics and to compare the stress levels of four attachment designs for mandibular overdentures retained by one central implant and two inclined distal implants. Photoelastic mandibular models fabricated with three screw-type implants (Tapered Screw-Vent, 3.75 × 13 mm) were placed in the parasymphyseal area. The center implant was vertically oriented to the midline, and the other implants were embedded in the canine areas with a 20-degree angulation relative to the center implant. Four overdentures with different attachment designs (bar, bar/ball, bar/distally placed Rk-1s, and Locators) were studied in the context of this model. Vertical loads (100 N) were applied to the central fossa of the right first molar area of each overdenture. Stress levels that developed in the denture-bearing areas and around the implants were observed photoelastically and evaluated visually. The studied attachment designs showed low and moderate stress levels. The greatest stress was found with the bar/ball design, while the lowest stress levels were observed with the Locator attachment design. Stresses were concentrated on the loaded side for each design. All tested designs experienced moderate stress around the posterior edentulous area. None of the designs experienced more than moderate stress. The lowest stress was noted with the Locator attachments, which transmitted little discernible stress around the implants.

  12. The Nano-filters as the tools for the management of the water imbalance in the human society

    Science.gov (United States)

    Singh, R. P.; Kontar, V.

    2011-12-01

    ultra-thin nanoscale fibers, which filter out contaminants, plus active carbon granules, which kill bacteria. The carbon nano-tube as filters exhibit chemical-species selectivity with higher physical strength and higher temperature tolerance, more rugged process, more rapid filtration, regeneration via thermal means rather than physical removal and lowers costs. The nano-filters remove the toxic or unwanted bivalent ions (ions with 2 or more charges), such as lead, iron, nickel, mercury, etc. The nano-materials and nano-filters will help solve the problems of the water imbalance management in the human society. Therefore we are talking about some nano-applications on the session H138 "Imbalance of Water in Nature".

  13. Design basis and requirements for 241-SY Modular Exhauster concrete pad and retaining wall

    International Nuclear Information System (INIS)

    Kriskovich, J.R.

    1994-01-01

    The purpose of this document is to serve as the design and functional requirements for a concrete pad for the new 241-SY Modular Exhauster and for a retaining wall to be built near the new ventilation systems

  14. Development of an earth pressure model for design of earth retaining structures in piedmont soil.

    Science.gov (United States)

    2008-10-01

    Anecdotal evidence suggests that earth pressure in Piedmont residual soils is typically over estimated. Such estimates of earth pressure impact the design of earth retaining structures used on highway projects. Thus, the development of an appropriate...

  15. Earth retaining structures manual

    Science.gov (United States)

    2009-10-29

    The objectives of this policy are to obtain statewide uniformity, establish standard : procedures and delineate responsibility for the preparation and review of plans, : design and construction control of earth retaining structures. In addition, it i...

  16. Retainer Positioner

    Directory of Open Access Journals (Sweden)

    Sanjeeb Kumar Sahu

    2012-01-01

    Full Text Available Several techniques are used to keep the retainer wire in the proper position during direct bonding, of lingual bonded retainers. Proper placement helps prevent occlusal wear of the composite over the retainer wire, thus reducing the risk of breakage. This article describes a new chairside time saving retainer positioner which allows accurate placement and direct bonding of all types of fixed lingual retainers, with solid or multistranded wires.

  17. Reliability Coupled Sensitivity Based Design Approach for Gravity Retaining Walls

    Science.gov (United States)

    Guha Ray, A.; Baidya, D. K.

    2012-09-01

    Sensitivity analysis involving different random variables and different potential failure modes of a gravity retaining wall focuses on the fact that high sensitivity of a particular variable on a particular mode of failure does not necessarily imply a remarkable contribution to the overall failure probability. The present paper aims at identifying a probabilistic risk factor ( R f ) for each random variable based on the combined effects of failure probability ( P f ) of each mode of failure of a gravity retaining wall and sensitivity of each of the random variables on these failure modes. P f is calculated by Monte Carlo simulation and sensitivity analysis of each random variable is carried out by F-test analysis. The structure, redesigned by modifying the original random variables with the risk factors, is safe against all the variations of random variables. It is observed that R f for friction angle of backfill soil ( φ 1 ) increases and cohesion of foundation soil ( c 2 ) decreases with an increase of variation of φ 1 , while R f for unit weights ( γ 1 and γ 2 ) for both soil and friction angle of foundation soil ( φ 2 ) remains almost constant for variation of soil properties. The results compared well with some of the existing deterministic and probabilistic methods and found to be cost-effective. It is seen that if variation of φ 1 remains within 5 %, significant reduction in cross-sectional area can be achieved. But if the variation is more than 7-8 %, the structure needs to be modified. Finally design guidelines for different wall dimensions, based on the present approach, are proposed.

  18. Evaluation of Causes of Retaining Wall Failure

    Directory of Open Access Journals (Sweden)

    Mu'azu Mohammed ABDULLAHI

    2009-07-01

    Full Text Available Retaining structures are vital geotechnical structure, because the topography of the earth surface is a combination of plain, sloppy and undulating terrain. The retaining wall resists thrust of a bank of earth as well as providing soil stability of a change of ground elevation. Earth pressures on retaining wall are designed from theories of Soil Mechanics, but unfortunately the engineers using them do not always realize the significance of the assumption in their development. This is usually accompanied by with failure and partial failures because of designed based on rules and formulae that fit only limited conditions. In addition there are also problems of using bad backfill materials without taking precautionary measures against built–up of hydrostatic pressure by provision of drainage and also poor workmanship.

  19. Influence of retainer design on two-unit cantilever resin-bonded glass fiber reinforced composite fixed dental prostheses: an in vitro and finite element analysis study.

    Science.gov (United States)

    Keulemans, Filip; De Jager, Niek; Kleverlaan, Cornelis J; Feilzer, Albert J

    2008-10-01

    The aim of this study was to evaluate in vitro the influence of retainer design on the strength of two-unit cantilever resin-bonded glass fiber-reinforced composite (FRC) fixed dental prostheses (FDP). Four retainer designs were tested: a proximal box, a step-box, a dual wing, and a step-box-wing. Of each design on 8 human mandibular molars, FRC-FDPs of a premolar size were produced. The FRC framework was made of resin impregnated unidirectional glass fibers (Estenia C&B EG Fiber, Kuraray) and veneered with hybrid resin composite (Estenia C&B, Kuraray). Panavia F 2.0 (Kuraray) was used as resin luting cement. FRC-FDPs were loaded to failure in a universal testing machine. One-way ANOVA and Tukey's post-hoc test were used to evaluate the data. The four designs were analyzed with finite element analysis (FEA) to reveal the stress distribution within the tooth/restoration complex. Significantly lower fracture strengths were observed with inlay-retained FDPs (proximal box: 300 +/- 65 N; step-box: 309 +/- 37 N) compared to wing-retained FDPs (p optimal design for replacement of a single premolar by means of a two-unit cantilever FRC-FDPs.

  20. Analysis of Different Positions of Fiber-Reinforced Composite Retainers versus Multistrand Wire Retainers Using the Finite Element Method

    Directory of Open Access Journals (Sweden)

    Arezoo Jahanbin

    2014-01-01

    Full Text Available Background. The aim of this study was to evaluate root displacement of the lower incisors fixed with FRC in different positions versus FSW retainers using the finite element method. Materials and Methods. 3D finite element models were designed for a mandibular anterior segment: Model 1: flexible spiral wire bonded to the lingual teeth surfaces, Model 2: FRC bonded to the upper third of lingual teeth surfaces, and Model 3: FRC bonded to the middle third. FE analysis was performed for three models and then tooth displacements were evaluated. Results. In contrast to lateral incisors and canines, the FSW retainer caused the central teeth to move more than the teeth bonded with FRC in both loadings. Comparison between Models 2 and 3 (in vertical loading showed that FRC retainers that bonded at the upper third of lingual teeth surfaces made central and canine teeth move less than FRC retainers bonded at the middle third; however, for lateral teeth it was the opposite. Conclusion. FRC retainers bonded at the upper third of lingual teeth surfaces make central and canine teeth move less than FRC retainers bonded at the middle third in vertical loading; however, for lateral teeth it was the opposite.

  1. Large Scale Testing of Drystone Retaining Structures

    OpenAIRE

    Mundell, Chris

    2009-01-01

    Drystone walls have been used extensively around the world as earth retaining structures wherever suitable stone is found. Commonly about 0.6m thick (irrespective of height), there are about 9000km of drystone retaining walls on the UK road network alone, mostly built in the 19th and early 20th centuries, with an estimated replacement value in excess of £1 billion[1]. Drystone wall design is traditionally empirical, based on local knowledge of what has worked in the past. Methods vary from re...

  2. Study of supercritical CO2 extraction and nanofiltration membrane separation coupling

    International Nuclear Information System (INIS)

    Sarrade, S.

    1994-12-01

    The aim of this thesis is to study the coupling of two extraction techniques, nanofiltering and supercritical fluids, designing and building an experimental device that enables both supercritical CO 2 extraction and nanofiltering membrane separation. The purpose is to reach high splitting up levels on small molecule mixtures. The document is divided in four parts : a bibliographic study on these two techniques; a description of the membranes and the products, as well as the experimental device; the characterization and modelization of transfer mechanism in aqueous solutions; a presentation of the results obtained by coupling the two techniques. (TEC). 45 tabs., 70 figs., 98 refs

  3. Performance of integrated retainer rings in silicon micro-turbines with thrust style micro-ball bearings

    International Nuclear Information System (INIS)

    Hergert, Robert J; Holmes, Andrew S; Hanrahan, Brendan; Ghodssi, Reza

    2013-01-01

    This work explores the performance of different silicon retainer ring designs when integrated into silicon micro-turbines (SMTs) incorporating thrust style bearings supported on 500 µm diameter steel balls. Experimental performance curves are presented for SMTs with rotor diameters of 5 mm and 10 mm, each with five different retainer designs varying in mechanical rigidity, ball pocket shape and ball complement. It was found that the different retainer designs yielded different performance curves, with the closed pocket designs consistently requiring lower input power for a given rotation speed, and the most rigid retainers giving the best performance overall. Both 5 mm and 10 mm diameter devices have shown repeatable performance at rotation speeds up to and exceeding 20 000 RPM with input power levels below 2 W, and devices were tested for over 2.5 million revolutions without failure. Retainer rings are commonly used in macro-scale bearings to ensure uniform spacing between the rolling elements. The integration of retainers into micro-bearings could lower costs by reducing the number of balls required for stable operation, and also open up the possibility of ‘smart’ bearings with integrated sensors to monitor the bearing status. (paper)

  4. Reliability Analysis of Retaining Walls Subjected to Blast Loading by Finite Element Approach

    Science.gov (United States)

    GuhaRay, Anasua; Mondal, Stuti; Mohiuddin, Hisham Hasan

    2018-02-01

    Conventional design methods adopt factor of safety as per practice and experience, which are deterministic in nature. The limit state method, though not completely deterministic, does not take into account effect of design parameters, which are inherently variable such as cohesion, angle of internal friction, etc. for soil. Reliability analysis provides a measure to consider these variations into analysis and hence results in a more realistic design. Several studies have been carried out on reliability of reinforced concrete walls and masonry walls under explosions. Also, reliability analysis of retaining structures against various kinds of failure has been done. However, very few research works are available on reliability analysis of retaining walls subjected to blast loading. Thus, the present paper considers the effect of variation of geotechnical parameters when a retaining wall is subjected to blast loading. However, it is found that the variation of geotechnical random variables does not have a significant effect on the stability of retaining walls subjected to blast loading.

  5. A Market-Driven Approach to Retaining Talent.

    Science.gov (United States)

    Cappelli, Peter

    2000-01-01

    Employee retention must be rethought in a free-agent market. Compensation can shape who leaves and stays. Job design and customization can tailor jobs to employee needs. Encouraging social ties among colleagues and selecting appealing locations for workplaces are other ways to retain talented workers. (SK)

  6. Knowledge and attitude of dentists toward implant retained ...

    African Journals Online (AJOL)

    2014-09-13

    Sep 13, 2014 ... and 80% of GDP used SRR in <50% and <25% of their implant practice respectively. ..... micro‑gap formation resulting in plaque accumulation and .... opening in screw‑or cement‑retained implant fixed partial denture designs.

  7. NERVA turbopump bearing retainer fabrication on nonmetallic retainer

    Science.gov (United States)

    Accinelli, J. B.

    1972-01-01

    The need for a low-wear, lightweight, high strength bearing retainer material with a radiation degradation threshold of 10 to the 9th power rads (C) prompted development of nonmetallic reinforced polymers of the following types: (1) polybenzimidazole, (2) polyimide, and (3) polyquinoxaline. Retainers were machined from tubular laminates (billets), including reinforcement by either glass or graphite fabric or filament. Fabrication of billets involves hot preimpregnation of the reinforcement fabric or filament with polymer followed by wrapping this prepreg over a heated mandrel to form a tube with the required thickness and length.

  8. Strain characteristics of Marburg double crown-retained implant overdentures compared with bar and ball-retained implant overdentures, with and without a rigid major connector.

    Science.gov (United States)

    Kazokoğlu, F Şehnaz; Akaltan, Funda

    2014-12-01

    It is hard to identify the most favorable retainer type and the denture design when considering strain levels around implants and in edentulous ridges for implant overdentures (IOVD). The purpose of this study was to evaluate the strain transmitted to the implants and edentulous ridges by Marburg double crown (MDC)-retained IOVD as opposed to bar and ball-retained IOVD and the efficiency of a rigid major connector in the maxilla. An in vitro maxillary model was prepared with 4 implants, with strain gauges placed distally to each implant and also in the anterior and posterior edentulous ridges. Five overdentures were fabricated for each MDC and each ball and bar attachment retainers. Vertical loads of 280 N were applied bilaterally on the first molar region. Then the palatal bars of each IOVD were disconnected, and loading procedures were repeated for the prostheses. No significant difference was observed among the MDC and the bar and ball-retained IOVD, with and without a rigid bar according to the data taken from both the implants and edentulous ridges. However, when the strain values attained from each strain gauge separately were considered, a slight difference was observed around the implants of ball-retained overdentures and in the edentulous ridges of MDC-retained overdentures. Within the limitations of this in vitro study, MDC-retained maxillary overdentures with 4 parallel and symmetrically placed implants can be used safely without a rigid major connector as with bar and ball-retained IOVD with regard to the strains generated in the edentulous ridge and around implants. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. 7 CFR 1767.25 - Retained earnings.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Retained earnings. 1767.25 Section 1767.25....25 Retained earnings. The retained earnings accounts identified in this section shall be used by all RUS borrowers. Retained Earnings 433-439 [Reserved] Retained Earnings 433-439 [Reserved] ...

  10. Design principles for engaging and retaining virtual citizen scientists.

    Science.gov (United States)

    Wald, Dara M; Longo, Justin; Dobell, A R

    2016-06-01

    Citizen science initiatives encourage volunteer participants to collect and interpret data and contribute to formal scientific projects. The growth of virtual citizen science (VCS), facilitated through websites and mobile applications since the mid-2000s, has been driven by a combination of software innovations and mobile technologies, growing scientific data flows without commensurate increases in resources to handle them, and the desire of internet-connected participants to contribute to collective outputs. However, the increasing availability of internet-based activities requires individual VCS projects to compete for the attention of volunteers and promote their long-term retention. We examined program and platform design principles that might allow VCS initiatives to compete more effectively for volunteers, increase productivity of project participants, and retain contributors over time. We surveyed key personnel engaged in managing a sample of VCS projects to identify the principles and practices they pursued for these purposes and led a team in a heuristic evaluation of volunteer engagement, website or application usability, and participant retention. We received 40 completed survey responses (33% response rate) and completed a heuristic evaluation of 20 VCS program sites. The majority of the VCS programs focused on scientific outcomes, whereas the educational and social benefits of program participation, variables that are consistently ranked as important for volunteer engagement and retention, were incidental. Evaluators indicated usability, across most of the VCS program sites, was higher and less variable than the ratings for participant engagement and retention. In the context of growing competition for the attention of internet volunteers, increased attention to the motivations of virtual citizen scientists may help VCS programs sustain the necessary engagement and retention of their volunteers. © 2016 Society for Conservation Biology.

  11. Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial.

    Science.gov (United States)

    Sobouti, Farhad; Rakhshan, Vahid; Saravi, Mahdi Gholamrezaei; Zamanian, Ali; Shariati, Mahsa

    2016-03-01

    Traditional retainers (both metal and fiber-reinforced composite [FRC]) have limitations, and a retainer made from more flexible ligature wires might be advantageous. We aimed to compare an experimental design with two traditional retainers. In this prospective preliminary clinical trial, 150 post-treatment patients were enrolled and randomly divided into three groups of 50 patients each to receive mandibular canine-to-canine retainers made of FRC, flexible spiral wire (FSW), and twisted wire (TW). The patients were monitored monthly. The time at which the first signs of breakage/debonding were detected was recorded. The success rates of the retainers were compared using chi-squared, Kaplan-Meier, and Cox proportional-hazard regression analyses (α = 0.05). In total, 42 patients in the FRC group, 41 in the FSW group, and 45 in the TW group completed the study. The 2-year failure rates were 35.7% in the FRC group, 26.8% in the FSW group, and 17.8% in the TW group. These rates differed insignificantly (chi-squared p = 0.167). According to the Kaplan-Meier analysis, failure occurred at 19.95 months in the FRC group, 21.37 months in the FSW group, and 22.36 months in the TW group. The differences between the survival rates in the three groups were not significant (Cox regression p = 0.146). Although the failure rate of the experimental retainer was two times lower than that of the FRC retainer, the difference was not statistically significant. The experimental TW retainer was successful, and larger studies are warranted to verify these results.

  12. Design and construction of earth retaining walls with anchors employed in excavation works at Oi Nuclear Power Plant

    International Nuclear Information System (INIS)

    Saino, Susumu; Aoshima, Ken-ichiro; Kamide, Atsushi.

    1990-01-01

    In Oi Nuclear Power Station, Kansai Electric Power Co., Inc., No.3 and No.4 plants of each 1180 MWe output are additionally installed, neighboring existing No.1 and No.2 plants of each 1175 MWe output in operation. The start of operation is expected in December, 1991 in No.3 plant, and in February, 1993 in No.4 plant. The total quantity of earth excavated for this additional installation works is about 3.3 million m 3 . The main works are, subsequently to the preparation of the site, the excavation for the foundations of reactor buildings and others, and the construction of the foundations for the seawater system facilities for cooling condensers and reactor auxiliary machines, and the works were begun in May, 1987. The excavation by using anchors was carried out in seven places. The vertical excavation on large scale was carried out by using the earth retaining walls of concrete-sprayed anchor structure in drain pits. In this report, the outline of the geological features, the outline of the excavation works, the design of the earth retaining walls, the execution of concrete spraying, the planning and result of measurement are described. (K.I.)

  13. A DESIGN METHOD FOR RETAINING WALL BASED ON RETURN PERIOD OF RAINFALL AND SNOWMELT

    Science.gov (United States)

    Ebana, Ryo; Uehira, Kenichiro; Yamada, Tadashi

    The main purpose of this study is to develop a new design method for the retaining wall in a cold district. In the cold district, snowfall and snowmelt is one of the main factors in sediment related disaster. However, the effect of the snowmelt is not being taken account of sediment disasters precaution and evacuation system. In this study, we target at past slope failure disaster and quantitatively evaluate that the effect of rainfall and snowmelt on groundwater level and then verify the stability of slope. Water supplied on the slope was determined from the probabilistic approach of the snowmelt using DegreeDay method in this study. Furthermore, a slope stability analysis was carried out based on the ground water level that was obtained from the unsaturated infiltration flow with the saturated seepage flow simulations. From the result of the slope stability analysis, it was found that the effect of ground water level on the stability of slope is much bigger than that of other factors.

  14. The stability of gabion walls for earth retaining structures

    Directory of Open Access Journals (Sweden)

    Mahyuddin Ramli

    2013-12-01

    Full Text Available The stability of earth retaining structures in flood prone areas has become a serious problem in many countries. The two most basic causes of failure arising from flooding are scouring and erosion of the foundation of the superstructure. Hence, a number of structures like bridges employ scour-arresting devices, e.g., gabions to acting on the piers and abutments during flooding. Research was therefore undertaken to improve gabion resistance against lateral movement by means of an interlocking configuration instead of the conventional stack-and-pair system. This involved simulating lateral thrusts against two dimensionally identical retaining wall systems configured according to the rectangular and hexagonal gabion type. The evolution of deformation observed suggested that the interlocking design exhibits better structural integrity than the conventional box gabion-based wall in resisting lateral movement and therefore warrants consideration for use as an appropriate scour-arresting device for earth retaining structures.

  15. Retained Herrick Plug

    Directory of Open Access Journals (Sweden)

    Justin B. Hellman

    2018-05-01

    Full Text Available A 79-year-old female with a history of keratoconjunctivitis sicca presented with several years of epiphora of both eyes. Thirteen years earlier, intracanalicular Herrick lacrimal plugs (Lacrimedics, Eastsound, WA, USA had been placed in both eyes to treat her dry eye syndrome. After 13 years the patient felt the epiphora was intolerable and underwent endoscopic dacryocystorhinostomy (DCR of the left, then the right side. Intraoperatively, during the right endoscopic DCR, a Herrick lacrimal plug was found in the common canaliculus into the lacrimal sac. Postoperatively, the patient did well with improved epiphora. The Herrick plug is designed to be intracanalicular, and this case illustrates that the plug can migrate and be retained for many years. Collared punctal plugs have a lower risk of this type of complication.

  16. Effect of Abutment Modification and Cement Type on Retention of Cement-Retained Implant Supported Crowns

    OpenAIRE

    Farzin, Mitra; Torabi, Kianoosh; Ahangari, Ahmad Hasan; Derafshi, Reza

    2014-01-01

    Objective: Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations. Materials and Method: Two prefabricated abutments were attached to their corresponding analogs and embedded in an ac...

  17. Retained surgical sponge

    International Nuclear Information System (INIS)

    Koyama, Masashi; Kurono, Kenji; Iida, Akihiko; Suzuki, Hirochika; Hara, Masaki; Mizutani, Hirokazu; Ohba, Satoru; Mizutani, Masaru; Nakajima, Yoichiro.

    1993-01-01

    The CT, US, and MRI findings of confirmed retained surgical sponges were reviewed. The CT examinations in eight lesions demonstrated round or oval masses with heterogeneous internal structures. The US examinations in 5 lesions demonstrated low echogenic masses with high echogenic internal structures, which suggested retained surgical sponges. MR imagings in three lesions showed slightly high intensity comparable to that of muscles on T1-weighted images and high signal intensity on T2-weighted images, suggesting fluid collections of high protein concentration. (author)

  18. 9 CFR 441.10 - Retained water.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Retained water. 441.10 Section 441.10... STANDARDS: RAW PRODUCTS § 441.10 Retained water. (a) Raw livestock and poultry carcasses and parts will not be permitted to retain water resulting from post-evisceration processing unless the establishment...

  19. The effects of fixed and removable orthodontic retainers: a systematic review

    Directory of Open Access Journals (Sweden)

    Dalya Al-Moghrabi

    2016-07-01

    Full Text Available Abstract Objective In the view of the widespread acceptance of indefinite retention, it is important to determine the effects of fixed and removable orthodontic retainers on periodontal health, survival and failure rates of retainers, cost-effectiveness, and impact of orthodontic retainers on patient-reported outcomes. Methods A comprehensive literature search was undertaken based on a defined electronic and gray literature search strategy (PROSPERO: CRD42015029169. The following databases were searched (up to October 2015; MEDLINE via OVID, PubMed, the Cochrane Central Register of Controlled Trials, LILACS, BBO, ClinicalTrials.gov, the National Research Register, and ProQuest Dissertation and Thesis database. Randomized and non-randomized controlled clinical trials, prospective cohort studies, and case series (minimum sample size of 20 with minimum follow-up periods of 6 months reporting periodontal health, survival and failure rates of retainers, cost-effectiveness, and impact of orthodontic retainers on patient-reported outcomes were identified. The Cochrane Collaboration’s Risk of Bias tool and Newcastle-Ottawa Scale were used to assess the quality of included trials. Results Twenty-four studies were identified, 18 randomized controlled trials and 6 prospective cohort studies. Of these, only 16 were deemed to be of high quality. Meta-analysis was unfeasible due to considerable clinical heterogeneity and variations in outcome measures. The mean failure risk for mandibular stainless steel fixed retainers bonded from canine to canine was 0.29 (95 % confidence interval [CI] 0.26, 0.33 and for those bonded to canines only was 0.25 (95 % CI: 0.16, 0.33. A meta-regression suggested that failure of fixed stainless steel mandibular retainers was not directly related to the period elapsed since placement (P = 0.938. Conclusion Further well-designed prospective studies are needed to elucidate the benefits and potential harms associated with

  20. Effects of the type and rigidity of the retainer and the number of abutting teeth on stress distribution of telescopic-retained removable partial dentures

    Directory of Open Access Journals (Sweden)

    Volkan Sahin

    2012-03-01

    Conclusion: RPDs with an ARTR and both retainer types with a rigid design produced more strain distal to the abutting teeth. Using more than two abutting teeth did not improve the strain patterns of the tested RPDs. More strain was produced on the posterior edentulous ridges.

  1. A new effect of retained austenite on ductility enhancement in high strength bainitic steel

    Energy Technology Data Exchange (ETDEWEB)

    Wang Ying; Zhang Ke; Guo Zhenghong; Chen Nailu [School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Rong Yonghua, E-mail: yhrong@sjtu.edu.cn [School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2012-08-30

    Highlights: Black-Right-Pointing-Pointer A new DARA effect in the bainitic steel is proposed. Black-Right-Pointing-Pointer The conditions of DARA effect are proposed. Black-Right-Pointing-Pointer The mechanism of retained austenite on ductility enhancement is clarified. - Abstract: A designed high strength bainitic steel with considerable amount of retained austenite is presented in order to study the effect of retained austenite on the ductility enhancement in bainitic steels. Transformation induced plasticity (TRIP) effect is verified by both X-ray diffraction (XRD) measurement of retained austenite fraction in various deformation stages and transmission electron microscopy observation of the deformed twin-type martensite. Results from XRD line profile analysis reveal that the average dislocation density in bainite during the deformation is lower than that before deformation, and such a phenomenon can be explained by a new effect, dislocations absorption by retained austenite (DARA) effect, based on our previous investigation of martensitic steels. DARA effect availably enhances the compatibility of deformation ability of bainite with retained austenite. In view of microstructure similarity of bainitic steels with martensitic steels, the conditions of DARA effect are proposed. The effects of retained austenite on the ductility enhancement in bainitic steels are clarified.

  2. Load Transfer Characteristics of Three-Implant-Retained Overdentures with Different Interimplant Distances.

    Science.gov (United States)

    Tokar, Emre; Uludag, Bulent; Karacaer, Ozgul

    Implant-retained overdentures are the first choice of rehabilitation for edentulous mandibles. Bone morphology and anatomical landmarks may be influenced by the location and angulation of implants and distances between the implants. The purpose of this study was to investigate stress distribution characteristics and to compare stress levels of three different attachment designs of three-implant-retained mandibular overdentures with three different interimplant distances. Three photoelastic mandibular models with three implants were fabricated using an edentulous mandible cast with moderate residual ridge resorption. The center implants were embedded parallel to the midline, and the distal implants were aligned at a 20-degree angulation corresponding to the center implants. Distances between the center and distal implants were set at 11, 18, and 25 mm at the photoelastic models. Bar, bar-ball, and Locator attachment-retained overdentures were prepared for the models. Vertical loads were applied to the overdentures, and stress levels and distribution were evaluated by a circular polariscope. The greatest observed stress level was moderate for the tested overdenture designs. The Locator attachment system showed the lowest stress level for the 11-mm and 25-mm photoelastic models. The bar attachment design transmitted less stress compared with the other tested designs for the 18-mm photoelastic model. Stresses were observed on the loaded side of the photoelastic models. The lowest stress was found with the Locator and bar attachments for the 11-mm photoelastic model, which transmitted little or no discernible stress around the implants.

  3. Model Tests on the Retaining Walls Constructed from Geobags Filled with Construction Waste

    Directory of Open Access Journals (Sweden)

    Hua Wen

    2016-01-01

    Full Text Available Geobag retaining wall using construction waste is a new flexible supporting structure, and the usage of construction waste to fill geobags can facilitate the construction recycling. In this paper, model tests were performed on geobag retaining wall using construction waste. The investigation was concentrated on the slope top settlement, the distribution characteristics of the earth pressures on retaining walls and horizontal wall displacements, and slope failure modes. The results indicated that the ultimate loads that the slope tops with retaining walls could bear were 87.5%~125% higher than that of the slope top without retaining walls. The ultimate loading of strengthened slopes with different slope ratios from 1 : 0.75 to 1 : 0.25 could be reduced by 11.8% to 29.4%. The horizontal displacements of the retaining walls constructed from geobags were distributed in a drum shape, with the greatest horizontal displacements occurring about 1/3~1/2 of the wall height away from the bottom of the wall. As the slope ratio increased, the failure of the slope soil supported by geobag retaining wall using construction waste changed from sliding to sliding-toppling (dominated by sliding and then to toppling-sliding (dominated by toppling. The range of 1/3~1/2 of wall height is the weak part of the retaining walls, which should be strengthened with certain measures during the process of design and construction.

  4. Finite Element Study of Three Different Treatment Designs of a Mandibular Three Implant-Retained Overdenture

    Directory of Open Access Journals (Sweden)

    M. Shishesaz

    Full Text Available Abstract This study compares ball, bar-clip and bar-ball attachment systems for implant-retained mandibular overdentures with three implants. The first implant is placed in the middle of the mandible and the other two are imbedded in the first premolar regions. Linear elastic finite element analysis is used for design analysis. Three dimensional geometry of the mandible is generated from computed tomography. Other parts are modeled using SolidWorks software. The foodstuff is positioned at the right first molar, representing the most frequent masticating situation. To obtain accurate mesh-independent results, finite element models are solved using several mesh grids. They are then validated by means of a detailed convergence analysis. The results demonstrate that the highest von-Mises stress in the bone is always located around the neck of the implant, at its upper threads. Ball and bar-ball attachments transfer the highest and lowest stresses to the bone surrounding the implants, respectively. The lowest stresses in the cortical and cancellous bones are due to bar-ball attachment. Yet, the overdenture gets its maximum movement for this arrangement. Consequently, the use of bar-ball attachment is only recommended for the cases in which stress transferred to peri-implant bone is more important than overdenture stability. Among the three treatment designs, ball attachment seems to exhibit the lowest lateral and overall displacements and hence, better overdenture stability.

  5. Acquisition and Retaining Granular Samples via a Rotating Coring Bit

    Science.gov (United States)

    Bar-Cohen, Yoseph; Badescu, Mircea; Sherrit, Stewart

    2013-01-01

    This device takes advantage of the centrifugal forces that are generated when a coring bit is rotated, and a granular sample is entered into the bit while it is spinning, making it adhere to the internal wall of the bit, where it compacts itself into the wall of the bit. The bit can be specially designed to increase the effectiveness of regolith capturing while turning and penetrating the subsurface. The bit teeth can be oriented such that they direct the regolith toward the bit axis during the rotation of the bit. The bit can be designed with an internal flute that directs the regolith upward inside the bit. The use of both the teeth and flute can be implemented in the same bit. The bit can also be designed with an internal spiral into which the various particles wedge. In another implementation, the bit can be designed to collect regolith primarily from a specific depth. For that implementation, the bit can be designed such that when turning one way, the teeth guide the regolith outward of the bit and when turning in the opposite direction, the teeth will guide the regolith inward into the bit internal section. This mechanism can be implemented with or without an internal flute. The device is based on the use of a spinning coring bit (hollow interior) as a means of retaining granular sample, and the acquisition is done by inserting the bit into the subsurface of a regolith, soil, or powder. To demonstrate the concept, a commercial drill and a coring bit were used. The bit was turned and inserted into the soil that was contained in a bucket. While spinning the bit (at speeds of 600 to 700 RPM), the drill was lifted and the soil was retained inside the bit. To prove this point, the drill was turned horizontally, and the acquired soil was still inside the bit. The basic theory behind the process of retaining unconsolidated mass that can be acquired by the centrifugal forces of the bit is determined by noting that in order to stay inside the interior of the bit, the

  6. [The impact of personality traits on adolescents' adaptation and compliance to clear retainers].

    Science.gov (United States)

    Xu, Fan; Tang, Guo-Hua

    2017-02-01

    The aim of this study was to evaluate the adolescents' adaptation and compliance to clear retainers, and to investigate their associations with personality traits. Fifty adolescents at the end of fixed orthodontic treatment were consecutively recruited. After debonding the fixed orthodontic appliances, clear retainers were used. Participants were asked to fill questionnaires 2 months after wearing the clear retainers. A questionnaire was designed to evaluate their adaptation and compliance for clear retianers. Eysenck personality questionnaire was used to assess the personality traits. Spearman rank correlation was used to analyze the associations between personality traits with the adaptation and compliance to clear retainers using SAS8.0 software package. Forty-two of 50 adolescents accomplished the questionnaires. 76% felt no mucous irritation, 95% felt no influence on socializing. However, 75% showed oral constraint, 71% felt impaired speech. Moreover, 40% adolescents wore the retainers less than 18 hours per day. 31% patients had their aligner lost. 83% patients did not brush their teeth after each meal. Neuroticism was positively associated with the effect of impaired chewing (r=0.32). Psychoticism was positively associated with the oral constraint (r=0.31) and facial muscular soreness (r=0.35), but negatively associated with the influence on emotion (r=-0.34). Extraversion was positively associated with the retainers' damage (r=0.31). Adolescents showed good adaptation for clear retainers, but unsatisfactory compliance. There are associations between adolescents' adaptation and compliance for clear retainers and personality traits. These results suggest that clinicians should pay more attention to the compliance of adolescents when using clear retainer. Personality traits could be a useful prediction to assess the compliance for clear aligners.

  7. 47 CFR 32.4550 - Retained earnings.

    Science.gov (United States)

    2010-10-01

    ... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.4550 Retained earnings. (a) This account shall include the undistributed balance of retained earnings derived from the...

  8. Abnormal Retained Earnings Around The World

    OpenAIRE

    Alves, Paulo; Silva, Paulo

    2017-01-01

    Using a firm-level survey database covering 50 countries we evaluate firms´ abnormal retained earnings. The results of our work indicate that firms located in emerging markets retain more earnings than firms from developed countries. On the other hand, firms located on common law based countries retain earnings above the expected and higher than firms placed on civil law based countries. A possible explanation, according to our results, can be seen in the economic growth that these countries ...

  9. Federal Aviation Administration retained savings program proposal

    International Nuclear Information System (INIS)

    Hostick, D.J.; Larson, L.L.; Hostick, C.J.

    1998-03-01

    Federal legislation allows federal agencies to retain up to 50% of the savings associated with implementing energy efficiency and water conservation measures and practices. Given budget pressures to reduce expenditures, the use of retained savings to fund additional projects represents a source of funds outside of the traditional budget cycle. The Southwest Region Federal Aviation Administration (FAA) has tasked Pacific Northwest National Laboratory (PNNL) to develop a model retained savings program for Southwest Region FAA use and as a prototype for consideration by the FAA. PNNL recommends the following steps be taken in developing a Southwest Region FAA retained savings program: Establish a retained savings mechanism. Determine the level at which the retained savings should be consolidated into a fund. The preliminary recommendation is to establish a revolving efficiency loan fund at the regional level. Such a mechanism allows some consolidation of savings to fund larger projects, while maintaining a sense of facility ownership in that the funds will remain within the region

  10. 17 CFR 256.215 - Appropriated retained earnings.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Appropriated retained earnings... UTILITY HOLDING COMPANY ACT OF 1935 Liabilities and Other Credit Accounts § 256.215 Appropriated retained earnings. This account shall include the amount of retained earnings which has been appropriated or set...

  11. General requirements for pressure-retaining systems and components in CANDU nuclear power plants

    International Nuclear Information System (INIS)

    1991-11-01

    This standard specifies the general requirements for the design, fabrication and installation of pressure-retaining systems, components, and their supports in CANDU nuclear power plants. (16 figs., 2 tabs., 25 refs.)

  12. Postpartum MR diagnosis of retained placenta accreta

    International Nuclear Information System (INIS)

    Tanaka, Yumiko Oishi; Itai, Yuji; Shigemitsu, Sadahiko; Ichikawa, Yoshihito; Sohda, Satoshi; Yoshikawa, Hiroyuki

    2004-01-01

    Retained placenta accreta can cause catastrophic postpartum hemorrhage. This study aims to determine whether MR imaging can differentiate retained placenta accreta from postpartum hemorrhage caused by other conditions. Fourteen cases suspicious for retained placenta were examined with MR imaging. Signal intensity, the enhancing pattern of uterine contents, and flow voids within the myometrium were retrospectively studied. As hysterectomy was performed in only two cases, final diagnosis was based on clinical outcome and analysis of uterine contents. Final diagnoses were retained placenta accreta in seven cases, retained normally attached placenta in four, hematoma in two, and placental site trophoblastic tumor (PSTT) in one. All seven cases with placenta accreta had a very hyperintense area on T2-weighted images, showing transient early enhancement. None demonstrated delayed strong enhancement around the hyperintense area. In two cases with retained normally attached placenta and in both with hematomas, there were no hyperintense areas on T2-weighted images. Of these, only one showed transient early enhancement. Flow voids were observed in four cases with placenta accreta, one with normally attached placenta, and the case with PSTT. A markedly hyperintense area on T2-weighted images and transient early enhancement without delayed strong enhancement between the mass and the myometrium can indicate retained placenta accreta. (orig.)

  13. Postpartum MR diagnosis of retained placenta accreta

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Yumiko Oishi; Itai, Yuji [Department of Radiology, Institute of Clinical Medicine, University of Tsukuba, 1-1-1 Tennodai, 305-8575, Tsukuba, Ibaraki (Japan); Shigemitsu, Sadahiko [Department of Obstetrics and Gynecology, Ryugasaki Saiseikai General Hospital, Ryagasaki (Japan); Ichikawa, Yoshihito; Sohda, Satoshi; Yoshikawa, Hiroyuki [Department of Obstetrics and Gynecology, Institute of Clinical Medicine, University of Tsukuba, 1-1-1 Tennodai, 305-8575, Tsukuba, Ibaraki (Japan)

    2004-06-01

    Retained placenta accreta can cause catastrophic postpartum hemorrhage. This study aims to determine whether MR imaging can differentiate retained placenta accreta from postpartum hemorrhage caused by other conditions. Fourteen cases suspicious for retained placenta were examined with MR imaging. Signal intensity, the enhancing pattern of uterine contents, and flow voids within the myometrium were retrospectively studied. As hysterectomy was performed in only two cases, final diagnosis was based on clinical outcome and analysis of uterine contents. Final diagnoses were retained placenta accreta in seven cases, retained normally attached placenta in four, hematoma in two, and placental site trophoblastic tumor (PSTT) in one. All seven cases with placenta accreta had a very hyperintense area on T2-weighted images, showing transient early enhancement. None demonstrated delayed strong enhancement around the hyperintense area. In two cases with retained normally attached placenta and in both with hematomas, there were no hyperintense areas on T2-weighted images. Of these, only one showed transient early enhancement. Flow voids were observed in four cases with placenta accreta, one with normally attached placenta, and the case with PSTT. A markedly hyperintense area on T2-weighted images and transient early enhancement without delayed strong enhancement between the mass and the myometrium can indicate retained placenta accreta. (orig.)

  14. A Computational Modeling Approach for Investigating Soft Tissue Balancing in Bicruciate Retaining Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Shahram Amiri

    2012-01-01

    Full Text Available Bicruciate retaining knee arthroplasty, although has shown improved functions and patient satisfaction compared to other designs of total knee replacement, remains a technically demanding option for treating severe cases of arthritic knees. One of the main challenges in bicruciate retaining arthroplasty is proper balancing of the soft tissue during the surgery. In this study biomechanics of soft tissue balancing was investigated using a validated computational model of the knee joint with high fidelity definitions of the soft tissue structures along with a Taguchi method for design of experiments. The model was used to simulate intraoperative balancing of soft tissue structures following the combinations suggested by an orthogonal array design. The results were used to quantify the corresponding effects on the laxity of the joint under anterior-posterior, internal-external, and varus-valgus loads. These effects were ranked for each ligament bundle to identify the components of laxity which were most sensitive to the corresponding surgical modifications. The resulting map of sensitivity for all the ligament bundles determined the components of laxity most suitable for examination during intraoperative balancing of the soft tissue. Ultimately, a sequence for intraoperative soft tissue balancing was suggested for a bicruciate retaining knee arthroplasty.

  15. A Computational Modeling Approach for Investigating Soft Tissue Balancing in Bicruciate Retaining Knee Arthroplasty

    Science.gov (United States)

    Amiri, Shahram; Wilson, David R.

    2012-01-01

    Bicruciate retaining knee arthroplasty, although has shown improved functions and patient satisfaction compared to other designs of total knee replacement, remains a technically demanding option for treating severe cases of arthritic knees. One of the main challenges in bicruciate retaining arthroplasty is proper balancing of the soft tissue during the surgery. In this study biomechanics of soft tissue balancing was investigated using a validated computational model of the knee joint with high fidelity definitions of the soft tissue structures along with a Taguchi method for design of experiments. The model was used to simulate intraoperative balancing of soft tissue structures following the combinations suggested by an orthogonal array design. The results were used to quantify the corresponding effects on the laxity of the joint under anterior-posterior, internal-external, and varus-valgus loads. These effects were ranked for each ligament bundle to identify the components of laxity which were most sensitive to the corresponding surgical modifications. The resulting map of sensitivity for all the ligament bundles determined the components of laxity most suitable for examination during intraoperative balancing of the soft tissue. Ultimately, a sequence for intraoperative soft tissue balancing was suggested for a bicruciate retaining knee arthroplasty. PMID:23082090

  16. Implant retained auricular prosthesis with a modified hader bar: a case report.

    Science.gov (United States)

    Lovely, M; Dathan, Pradeep C; Gopal, Dinesh; George, Biji Thomas; Chandrasekharan Nair, K

    2014-06-01

    Auricular prostheses for defects of external ear are retained either by mechanical means or implants. All implant retained prostheses are retained by various means such as bar and clip, magnetic attachments or a combination of bar, clip and magnets. The commonest problem encountered with the bar and clip system is loosening of the clip after 3-4 months. When magnets are used as retaining component they tend to corrode over a period of time. So various alternative retention methods which possess good retentive qualities, ease of reparability and patient friendly were tried. In the present case a newly modified Hader bar design which can act as an additional retentive feature apart from the clip is employed to increase retention. The major advantages in the modified Hader bar system were that only two implants were employed, the additional loops in the Hader bar prevented micro movements and the retentive acrylic locks were easy to repair if broken. The modified Hader bar has anti-rotational slots which prevents the sliding or rotation of the prosthesis which gave new confidence to the patient who was otherwise worried of inadvertent displacement of the ear prosthesis while playing.

  17. Test of active coal capacity for retaining gaseous effluents contaminated by 131 I

    International Nuclear Information System (INIS)

    Campeanu, Catalina; Cruceru, Madalina; Neacsu, Elena

    1999-01-01

    The aim of this paper is to test the retaining capacity of the active coal of the filters for gaseous effluents contaminated by 131 I. The active coal filters are design for equipping ventilation installations of nuclear plants in which radioactive iodine and combination of it were produced and handled. Such active coal filters are provided also to sorbonnes for radiochemical and physical handling of radioactive iodine. Testing the retaining capacity of active coal for filters is an obvious step, particularly, when the material was stored long time after preparation

  18. A retained menstrual cup.

    Science.gov (United States)

    Day, S

    2012-05-01

    A 20-year-old woman attended a genitourinary clinic with a retained vaginal Mooncup that she had inserted the night before. A Mooncup is one type of menstrual cup. On speculum examination the device was visualized high in the vagina and the cervix appeared firmly lodged within it. The physician experienced difficulty in retrieving the cup despite following product instructions. This case highlights a new adverse event with an increasingly used sanitation product. It is important that clinicians are familiar with the cup, its removal process and are able to counsel patients with retained devices on future correct placement.

  19. Rational use of anchor pile material of the thin retaining walls

    Directory of Open Access Journals (Sweden)

    Yushkov Boris Semenovich

    2014-12-01

    Full Text Available The article considers the urgency of application of the reinforced concrete anchor piles in the constructions of retaining structures associated with the possibility of establishing rigid joint of element interface and more durable pile constructions in the soil. The features of the inclined anchor piles work as a part of sheet-pile retaining walls are noted. There was performed a study of the stress-strain state of the inclined reinforced concrete anchor piles of the thin sheet-pile wall with the reinforced concrete face members of T-section, combined with piles by a longitudinal beam. The authors consider a constructive scheme of retaining structure and list the applied loads. The efforts in the anchor piles were determined. The bending-moment curves show the character of the force distribution along the pile. A form of the pile ensuring the rational distribution of material along the pile is presented. The distribution of efforts along the length and effect of filling on its operation in the soil were accepted as the criteria of construction solution for a pile. The substantiation of the proposed design of pile is presented in terms of its stress-strain state and the rational use of material. The authors made conclusions on the reasonability of adopted design solutions associated with an increase in the flexural strength of pile, increment of the ultimate pullout capacity, stability improvement, effective use of backfill and exception of the «out of operation» areas of the pile.

  20. Biomechanical analysis of posterior cruciate ligament retaining high-flexion total knee arthroplasty

    NARCIS (Netherlands)

    Zelle, J.; van der Zanden, A.C.; De Waal Malefijt, M.; Verdonschot, Nicolaas Jacobus Joseph

    2009-01-01

    Background High-flexion knee replacements have been developed to accommodate a large range of flexion (>120°) after total knee arthroplasty. Both posterior cruciate ligament retaining and sacrificing high-flexion knee designs have been marketed. The main objective of this study was to evaluate the

  1. Reality of Retainers

    Science.gov (United States)

    ... the cafeteria take out his retainer before eating lunch. Carefully, he places it in a plastic container to make sure that it's safe while he eats. You can tell that this small plastic and metal mouthpiece is important to him. ...

  2. Protozoan Bacterivory and Escherichia coli Survival in Drinking Water Distribution Systems

    Science.gov (United States)

    Sibille, I.; Sime-Ngando, T.; Mathieu, L.; Block, J. C.

    1998-01-01

    The development of bacterial communities in drinking water distribution systems leads to a food chain which supports the growth of macroorganisms incompatible with water quality requirements and esthetics. Nevertheless, very few studies have examined the microbial communities in drinking water distribution systems and their trophic relationships. This study was done to quantify the microbial communities (especially bacteria and protozoa) and obtain direct and indirect proof of protozoan feeding on bacteria in two distribution networks, one of GAC water (i.e., water filtered on granular activated carbon) and the other of nanofiltered water. The nanofiltered water-supplied network contained no organisms larger than bacteria, either in the water phase (on average, 5 × 107 bacterial cells liter−1) or in the biofilm (on average, 7 × 106 bacterial cells cm−2). No protozoa were detected in the whole nanofiltered water-supplied network (water plus biofilm). In contrast, the GAC water-supplied network contained bacteria (on average, 3 × 108 cells liter−1 in water and 4 × 107 cells cm−2 in biofilm) and protozoa (on average, 105 cells liter−1 in water and 103 cells cm−2 in biofilm). The water contained mostly flagellates (93%), ciliates (1.8%), thecamoebae (1.6%), and naked amoebae (1.1%). The biofilm had only ciliates (52%) and thecamoebae (48%). Only the ciliates at the solid-liquid interface of the GAC water-supplied network had a measurable grazing activity in laboratory test (estimated at 2 bacteria per ciliate per h). Protozoan ingestion of bacteria was indirectly shown by adding Escherichia coli to the experimental distribution systems. Unexpectedly, E. coli was lost from the GAC water-supplied network more rapidly than from the nanofiltered water-supplied network, perhaps because of the grazing activity of protozoa in GAC water but not in nanofiltered water. Thus, the GAC water-supplied network contained a functional ecosystem with well-established and

  3. The role of psychological ownership in retaining talent: A systematic literature review

    Directory of Open Access Journals (Sweden)

    Chantal Olckers

    2012-02-01

    Full Text Available Orientation: Managing psychological ownership can have positive attitudinal and behavioural effects, promote organisational effectiveness and support talent retention.Research purpose: This paper seeks to explore and describe psychological ownership, distinguish it from other work-related attitudes and clarify the role that psychological ownership can play in retaining talent.Motivation for the study: Previous studies of human resource practices and organisational characteristics that affect organisational commitment and the retention of talent have reported that absent variables could be responsible for varied results. Psychological ownership could be one of them.Research design, approach and method: Based on a systematic review of the literature published over the last 20 years, the authors synthesised various research perspectives into a framework of psychological ownership and its links to retaining talent.Main findings: The authors found that psychological ownership was a comprehensive multidimensional construct. It is distinct from other work-related attitudes and seems capable of enabling organisations to retain the talents of skilled employees.Practical/managerial implications: Organisations can benefit from psychological ownership because it leads employees to feel responsible towards targets (like organisations and to show stewardship. It can help organisations to retain talent and influence the intentions of skilled employees to remain with their organisations.Contribution/value-add: Psychological ownership, as an integrated multidimensional construct, has expanded the existing theory about the organisational commitment and work-related attitudes that organisations need to retain talent in the 21st century.

  4. Basic fracture toughness requirements for ferritic materials of nuclear class pressure retaining equipment in NPP

    International Nuclear Information System (INIS)

    Ning Dong; Yao Weida

    2005-01-01

    In this paper, theory basis on cold brittleness and anti-brittle fracture design of ferritic materials are introduced summarily and fracture toughness requirements for ferritic materials in ASME code for nuclear safety class pressure retaining equipment in NPP are summarized and evaluated. The results show that notch impact toughness requirements for materials relate to nuclear safety class of materials so as to ensure that brittle fracture of retaining pressure boundary in NPP can not occur. (authors)

  5. 76 FR 69126 - Graduated Retained Interests

    Science.gov (United States)

    2011-11-08

    ... in trust or otherwise) includible in the grantor's gross estate if the grantor has retained the use..., or for a period that does not in fact end before the grantor's death. The final regulations will... trust corpus of a grantor retained annuity or unitrust trust (GRT) that is includible in the grantor's...

  6. 31 CFR 203.16 - Retainer and investor depositaries.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Retainer and investor depositaries... TREASURY TAX AND LOAN PROGRAM PATAX § 203.16 Retainer and investor depositaries. (a) Credit to TIP main account balance. On the business day that the TSC receives an AOC from a retainer or investor depositary...

  7. Requirements for class 1C, 2C, and 3C pressure-retaining components and supports in CANDU nuclear power plants

    International Nuclear Information System (INIS)

    1989-01-01

    This Standard applies to pressure-retaining components of CANDU nuclear power plants that have a code classification of Class 1C, 2C or 3C. These are pressure-retaining components where, because of the design concept, the rules of the ASME Boiler and Pressure Vessel Code do not exist, are not applicable, or are not sufficient. The Standard provides rules for the design, fabrication, installation, examination and inspection of these components and supports. It provides rules intended to ensure the pressure-retaining integrity of components, not the operability. It also provides rules for the support of fueling machines. The Standard applies only to new construction prior to the plant being declared in service

  8. Design and development of a magnetic device for mesenchymal stem cell retaining in deep targets

    Science.gov (United States)

    Banis, G. C.

    2017-12-01

    This paper focuses on the retaining of mesenchymal stem cells in blood flow conditions using the appropriate magnetic field. Mesenchymal stem cells can be tagged with magnetic nanoparticles and thus, they can be manipulated from distance, through the application of an external magnetic field. In this paper the case of kidney as target of the therapy is being studied.

  9. Improved radiocarbon analyses of modern human hair to determine the year-of-death by cross-flow nanofiltered amino acids: common contaminants, implications for isotopic analysis, and recommendations.

    Science.gov (United States)

    Santos, Guaciara M; De La Torre, Hector A Martinez; Boudin, Mathieu; Bonafini, Marco; Saverwyns, Steven

    2015-10-15

    In forensic investigation, radiocarbon ((14)C) measurements of human tissues (i.e., nails and hair) can help determine the year-of-death. However, the frequent use of cosmetics can bias hair (14)C results as well as stable isotope values. Evidence shows that hair exogenous impurities percolate beyond the cuticle layer, and therefore conventional pretreatments are ineffective in removing them. We conducted isotopic analysis ((14)C, δ(13)C, δ(15)N and C/N) of conventionally treated and cross-flow nanofiltered amino acid (CFNAA)-treated samples (scalp- and body-hair) from a single female subject using fingernails as a reference. The subject studied frequently applies a permanent dark-brown dye kit to her scalp-hair and uses other care products for daily cleansing. We also performed pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) analyses of CFNAA-treated scalp-hair to identify contaminant remnants that could possibly interfere with isotopic analyses. The conventionally treated scalp- and body-hair showed (14)C offsets of ~21‰ and ~9‰, respectively. These offsets confirm the contamination by petrochemicals in modern human hair. A single CFNAA extraction reduced those offsets by ~34%. No significant improvement was observed when sequential extractions were performed, as it appears that the procedure introduced some foreign contaminants. A chromatogram of the CFNAA scalp-hair pyrolysis products showed the presence of petroleum and plant/animal compound residues, which can bias isotopic analyses. We have demonstrated that CFNAA extractions can partially remove cosmetic contaminants embedded in human hair. We conclude that fingernails are still the best source of keratin protein for year-of-death determinations and isotopic analysis, with body-hair and/or scalp-hair coupled with CFNAA extraction a close second. Copyright © 2015 John Wiley & Sons, Ltd.

  10. Periodontal implication of bonded and removable retainers: A comparative study

    Directory of Open Access Journals (Sweden)

    Sonali Mondal

    2017-09-01

    Full Text Available The purpose of this study is to compare the periodontal health of the lower anterior teeth retained with the use of removable and fixed retainers. Fifty four cases receiving comprehensive orthodontic treatment in between 10 to 30 years were randomly selected and divided into 2 groups of 27 each. One group was given removable retainers and other was given fixed retainers. The periodontal status of the patients was accessed with bleeding on probing index, Plaque index and Calculus index. The mean plaque index in case of removable retainers at 1st, 3rd and 6th month were 0.5, 1.0 and 1.7 where as in case of fixed retainers that were 1.8, 3.0 and 4.5. The mean dental calculus index in case of removable retainers at 1st, 3rd and 6th month were 0.0, 0.1 and 0.1 where as in case of fixed retainers that were 0.1, 0.9 and 1.8. In conclusion, removable retainers are superior in oral hygiene maintenance, yet the use of fixed retainers cannot be denied.

  11. Recruiting and Retaining Cyberwarriors

    National Research Council Canada - National Science Library

    Westermeyer, Roger H

    2008-01-01

    .... Recruiting and retaining this highly skilled workforce is a significant challenge for the Air Force due to the high public and private sector demand for people with IT and related engineering skills...

  12. An application of ultrasonic inspection system (INER-SCAN) inspecting generator retaining rings

    International Nuclear Information System (INIS)

    Chen, L.C.; Hwang, S.C.

    1994-01-01

    The performances of the automatic ultrasonic inspecting and imaging system (INER-SCAN) developed by the NDT laboratory of the Institute of Nuclear Energy Research have been enhanced and much more improved to commercial level. With appropriate rearrangements of software libraries, it is used to inspect generator retaining rings which are critical structural rotor components that support the end-turn regions of the rotor wingings against centrifugal forces. The use of the INER-SCAN provides distinct advantages over other systems in terms of the reliability of inspection and the flexibility of system performance modifications. The INER-SCAN system assists users to select and modify ultrasonic parameters under computer-aided environment. In addition, the INER-SCAN system contains the necessary software functions to image the ultrasonic data (A-SCAN, B-SCAN, B'-SCAN, C-SCAN). The use of the imaging system makes it quite easy to evaluate various test parameters and their effects on the discrimination between geometric and IGSCC reflectors. Through experimental test, it is recognized that the system has powerful detectable capability which can find 0.2mm-depth slight scratch on the inner surface of retaining rings. This system can also be used on different generator retaining rings (different in terms of hidden design features) without the need for access to the dimension of retaining ring

  13. 18 CFR 367.4360 - Account 436, Appropriations of retained earnings.

    Science.gov (United States)

    2010-04-01

    ..., Appropriations of retained earnings. 367.4360 Section 367.4360 Conservation of Power and Water Resources FEDERAL... NATURAL GAS ACT Retained Earnings Accounts § 367.4360 Account 436, Appropriations of retained earnings. This account must include appropriations of retained earnings as follows: (a) Appropriations required...

  14. 17 CFR 256.216 - Unappropriated retained earnings.

    Science.gov (United States)

    2010-04-01

    ... retained earnings. This account shall include the balance, either debit or credit, arising from earnings... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Unappropriated retained earnings. 256.216 Section 256.216 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION...

  15. Floating retained root lesion mimicking apical periodontitis.

    Science.gov (United States)

    Chung, Ming-Pang; Chen, Chih-Ping; Shieh, Yi-Shing

    2009-10-01

    A case of a retained root tip simulating apical periodontitis on radiographic examination is described. The retained root tip, originating from the left lower first molar, floated under the left lower second premolar apical region mimicking apical periodontitis. It appeared as an ill-defined periapical radiolucency containing a smaller radiodense mass on radiograph. The differential diagnosis included focal sclerosing osteomyelitis (condensing osteitis) and ossifying fibroma. Upon exicisional biopsy, a retained root associated with granulation tissue was found. After 1-year follow-up, the patient was asymptomatic and the periradicular lesion was healing. Meanwhile, the associated tooth showed a normal response to stimulation testing.

  16. Unexpected complications of bonded mandibular lingual retainers.

    NARCIS (Netherlands)

    Katsaros, C.; Livas, C.; Renkema, A.M.

    2007-01-01

    INTRODUCTION: The flexible spiral wire (FSW) retainer is the most frequently used type of fixed retainer bonded on all 6 anterior teeth. Our aim in this article was to demonstrate unexpected posttreatment changes in the labiolingual position of the mandibular anterior teeth associated with the use

  17. Reoccurrence of retained placenta at vaginal delivery

    DEFF Research Database (Denmark)

    Nikolajsen, Sys; Løkkegaard, Ellen Christine Leth; Bergholt, Thomas

    2013-01-01

    To estimate the prevalence and validate the diagnosis of retained placenta in nulliparous women and the risk of reoccurrence at subsequent vaginal delivery.......To estimate the prevalence and validate the diagnosis of retained placenta in nulliparous women and the risk of reoccurrence at subsequent vaginal delivery....

  18. Soil Retaining Structures : Development of models for structural analysis

    NARCIS (Netherlands)

    Bakker, K.J.

    2000-01-01

    The topic of this thesis is the development of models for the structural analysis of soil retaining structures. The soil retaining structures being looked at are; block revetments, flexible retaining walls and bored tunnels in soft soil. Within this context typical structural behavior of these

  19. 18 CFR 367.2160 - Account 216, Unappropriated retained earnings.

    Science.gov (United States)

    2010-04-01

    ..., Unappropriated retained earnings. 367.2160 Section 367.2160 Conservation of Power and Water Resources FEDERAL... retained earnings. This account must include the balances, either debit or credit, of unappropriated retained earnings arising from earnings of the service company. This account must not include any amounts...

  20. 21 CFR 882.4800 - Self-retaining retractor for neurosurgery.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Self-retaining retractor for neurosurgery. 882...-retaining retractor for neurosurgery. (a) Identification. A self-retaining retractor for neurosurgery is a self-locking device used to hold the edges of a wound open during neurosurgery. (b) Classification...

  1. 18 CFR 367.2150 - Account 215, Appropriated retained earnings.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 215, Appropriated retained earnings. 367.2150 Section 367.2150 Conservation of Power and Water Resources FEDERAL... retained earnings. This account must include the amount of retained earnings that has been appropriated or...

  2. Total rewards that retain: A study of demographic preferences

    Directory of Open Access Journals (Sweden)

    Monica Pregnolato

    2017-01-01

    Full Text Available Orientation: Changing workplace demographics and a dearth of employees with scarce skills have forced employers to better understand the various factors that retain talented employees. Research purpose: In this empirical study, the reward preferences and ideal combination of total reward elements (based on an estimation of their relative importance that retain employees from various demographic groups, including employees of different race, gender and age groups, were investigated. Motivation for study: Organisations are competing for talented employees and to benefit from the value these individuals add, it is required of them to stay at the respective businesses. Previous studies have indicated that employees who are offered a reward package that is aligned to their personal preferences are prone to stay longer at the organisation and to be more engaged at work. However, new and novel ways need to be found to identify the reward preferences of employees. Research design, approach and method: A quantitative approach and descriptive research design was employed to estimate the individual reward preferences and identify an ideal mix of total reward elements that retain different cohorts of employees. Three questionnaires were distributed, including a Remuneration Managers Questionnaire (n = 7, a Remuneration Preference Questionnaire (n = 368 and a Choice-based Conjoint Task Questionnaire (n = 368. The latter two questionnaires were distributed as an online questionnaire to South African businesses and consisted of eight choice-based conjoint tasks, as well as a field survey. Main findings: The results of the choice-based conjoint analysis revealed that all respondents considered financial rewards (Benefits, Performance and Recognition, Remuneration, Career, in that order as relatively speaking, the most important components in their total rewards package that would lead to their retention. For most demographic groups, the remaining three places

  3. The effects of operating factors on the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic trout fish farm wastewater through nanofiltration

    International Nuclear Information System (INIS)

    Cheshmberah, F.; Solaimany Nazar, A.R.; Farhadian, M.

    2016-01-01

    An aquaculture system can be a potentially significant source of antibacterial compounds and ammonia in an aquatic environment. In this study, the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic aqueous wastewater was assessed by applying a commercial thin film composite polyamide nanofilter. The effects of p H (6.5-8.5), pressure (4-10 bar), concentration of total ammonia nitrogen (1-9 mg/L), and florfenicol (0.2-5 mg/L) on the removal efficiency of the nanofilter were studied at a constant 70% recovery rate. It was found that by increasing the p H within the range of 6.5 to 8.5, it enhanced the removal efficiency by up to 98% and 100% for total ammonia nitrogen and florfenicol, respectively. With an increase in pressure from 4 to 7 bar, the removal percentage increased and then, it decreased from 7 to 10 bar. The interactions factors did not have significant effects on the both pollutants removal efficiencies. To obtain optimal removal efficiencies, an experimental design and statistical analysis via the response surface method were adopted.

  4. CONDUCTING AND ANALYZING THE RESULTS OF THE EXPERIMENTAL BOX TEST OF RETAINING WALL MODELS WITHOUT PILES AND ON THE PILE FOUNDATION

    Directory of Open Access Journals (Sweden)

    M. A. Lisnevskyi

    2015-08-01

    Full Text Available Purpose. Taking into consideration that the bearing capacity of the foundation may be insufficient, in the study it is assumed that pile foundation can be used to reduce the impact of the construction of new retaining structures on roads and railways near the existing buildings or in areas of dense urban development and ensure the stability of the foundation. To reduce the volume of excavation it is necessary to choose the economic structure of the retaining wall. To do this, one should explore stress-strain state (SSS of the retaining walls, to develop methods to improve their strength and stability, as well as to choose the most appropriate method of their analysis. Methodology. In the design of retaining walls foundation mat and piles are considered as independent elements. Since the combined effect of the retaining wall, piles and foundation mat as well as the effect of soil or rock foundation on the structure are considered not fully, so there are some limitations in the existing design techniques. To achieve the purpose the box tests of retaining walls models without piles and with piles for studying their interaction with the surrounding soil massif were conducted. Findings. Laboratory simulation of complex systems «surrounding soil – retaining wall – pile» was carried out and on the basis of the box test results were analyzed strains and its main parameters of the stress-strain state. Analysis of the results showed that the structure of a retaining wall with piles is steady and stable. Originality. So far, in Ukraine has not been carried out similar experimental box tests with models of retaining walls in such combinations. In the article has been presented unique photos and test results, as well as their analysis. Practical value. Using the methodology of experimental tests of the retaining wall models with piles and without them gives a wider opportunity to study stress-strain state of such structures.

  5. Requirements for class 1, 2, and 3 pressure-retaining systems and components in CANDU nuclear power plants

    International Nuclear Information System (INIS)

    1991-09-01

    This third edition of CAN/CSA-N285.1 supersedes the 1981 and 1975 editions. It provides the specific requirements for design, fabrication, and installation of Class 1, 2 and 3 pressure-retaining systems and components in CANDU nuclear power plants, and over pressure protection of the heat transport system. The general requirements for pressure-retaining systems and components are given in CSA Standard CAN/CSA-N285.0, with which Class 1, 2 and 3 systems and components must also comply

  6. Retaining the older workforce: social policy considerations for the universally designed workplace.

    Science.gov (United States)

    Timmons, Jaimie Ciulla; Hall, Allison Cohen; Fesko, Sheila Lynch; Migliore, Alberto

    2011-04-01

    Even in the midst of massive layoffs that come with an economic downturn, employers must remain aware of the pending impact of their aging workforce. Losing older employees to retirement drains knowledge and expertise. In response, employers are looking at new ways to retain older workers at the same time that older workers are reevaluating the traditional approach to retirement. This article presents findings from case study research consisting of interviews with key employees at 18 companies in 13 states. Five of those companies subsequently participated in in-person site visits. Interviews were held with a wide range of informants, including company leadership, supervisors, and older workers. Findings include a description of the cultural context within which the development of formal and informal older worker retention strategies occurred, as well as the retention strategies themselves. The discussion section explores the universal nature of these retention initiatives and how consideration of universality benefits not only older workers but a range of diverse groups as well.

  7. 18 CFR 367.4390 - Account 439, Adjustments to retained earnings.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Account 439, Adjustments to retained earnings. 367.4390 Section 367.4390 Conservation of Power and Water Resources FEDERAL... NATURAL GAS ACT Retained Earnings Accounts § 367.4390 Account 439, Adjustments to retained earnings. (a...

  8. Effect of small addition of Cr on stability of retained austenite in high carbon steel

    Energy Technology Data Exchange (ETDEWEB)

    Hossain, Rumana; Pahlevani, Farshid, E-mail: f.pahlevani@unsw.edu.au; Sahajwalla, Veena

    2017-03-15

    High carbon steels with dual phase structures of martensite and austenite have considerable potential for industrial application in high abrasion environments due to their hardness, strength and relatively low cost. To design cost effective high carbon steels with superior properties, it is crucial to identify the effect of Chromium (Cr) on the stability of retained austenite (RA) and to fully understand its effect on solid-state phase transition. This study addresses this important knowledge gap. Using standard compression tests on bulk material, quantitative X-ray diffraction analysis, nano-indentation on individual austenitic grains, transmission electron microscopy and electron backscatter diffraction–based orientation microscopy techniques, the authors investigated the effect of Cr on the microstructure, transformation behaviour and mechanical stability of retained austenite in high carbon steel, with varying Cr contents. The results revealed that increasing the Cr %, altered the morphology of the RA and increased its stability, consequently, increasing the critical pressure for martensitic transformation. This study has critically addressed the elastoplastic behaviour of retained austenite – and provides a deep understanding of the effect of small additions of Cr on the metastable austenite of high carbon steel from the macro- to nano-level. Consequently, it paves the way for new applications for high carbon low alloy steels. - Highlights: • Effect of small addition of Cr on metastable austenite of high carbon steel from the macro- to nano-level • A multi-scale study of elastoplastic behaviour of retained austenite in high carbon steel • The mechanical stability of retained austenite during plastic deformation increased with increasing Cr content • Effect of grain boundary misorientation angle on hardness of individual retained austenite grains in high carbon steel.

  9. A soft-rigid contact model of MPM for granular flow impact on retaining structures

    Science.gov (United States)

    Li, Xinpo; Xie, Yanfang; Gutierrez, Marte

    2018-02-01

    Protective measures against hazards associated with rapid debris avalanches include a variety of retaining structures such as rock/boulder fences, gabions, earthfill barriers and retaining walls. However, the development of analytical and numerical methods for the rational assessment of impact force generated by granular flows is still a challenge. In this work, a soft-rigid contact model is built under the coding framework of MPM which is a hybrid method with Eulerian-Lagrangian description. The soft bodies are discretized into particles (material points), and the rigid bodies are presented by rigid node-based surfaces. Coulomb friction model is used to implement the modeled contact mechanics, and a velocity-dependent friction coefficient is coupled into the model. Simulations of a physical experiment show that the peak and residual value of impact forces are well captured by the MPM model. An idealized scenario of debris avalanche flow down a hillslope and impacting on a retaining wall are analyzed using the MPM model. The calculated forces can provide a quantitative estimate from which mound design could proceed for practical implementation in the field.

  10. An unrecognized foreign body retained in the calcaneus

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ro Woon; Choi, Soo Jung; Hwang, Jae Kwang; Ahn, Jae Hong; Kang, Chae Hoon; Shin, Dong Rock [Gangneung Asan Hospital, College of Medicine, University of Ulsan, Gangneung (Korea, Republic of)

    2017-06-15

    We describe a case of an unrecognized foreign body retained in the calcaneus. The patient denied any history of trauma. The skin overlying the calcaneus was intact with no local signs of inflammation. The retained foreign body was not observed on the radiograph of the calcaneus. Magnetic Resonance Imaging showed a tubular low signal intensity lesion in the calcaneal body, surrounded by strongly enhanced soft tissue and bone marrow edema caused by a foreign body reaction. A foreign body retained in the calcaneus was suspected on the basis of these findings. Surgical exploration and curettage was performed, and a rod shaped wooden fragment was found.

  11. Peripartal leukogram in cows with and without retained placenta

    Directory of Open Access Journals (Sweden)

    Lužajić Tijana

    2014-01-01

    Full Text Available The aim of this study was to investigate whether prepartal leukogram in cows with retained placenta could indicate the presence of subclinical systemic inflammatory response before the onset of disease. After calving, sixteen highly pregnant Holstein cows, aged 3 to 9 years, without clinical signs of the disease prior to calving were divided into two groups: the first group (n=9 were animals without retained placenta, or any visible inflammation after birth; the second group (n=7 were cows with retained placenta. Blood was sampled three times before parturition, at intervals of one week, and once 24 hours after birth. The number of total leukocytes, segmented and non segmented neutrophilic granulocytes (NG, lymphocytes and monocytes were determined by standard laboratory techniques. The results have shown that in the group of cows with retained placenta the number of mature neutrophils was slightly elevated in the third, second and last week before calving, and equal number of non segmented neutrophils in regard to the group with no retention. The results have also shown that, in both groups of cows, 24 hours after calving, the number of total leukocytes and the number of segmented neutrophils decreased, but the number of the non segmented neutrophils increased. Based on this, we can conclude that cows with retained placenta had no systemic inflammatory response during three weeks prepartal period, but 24 hours after calving, systemic inflammatory response was documented in all the cows. Moreover, the intensity of inflammatory response in cows with retained placenta was not more pronounced in comparison to cows without retained placenta. [Projekat Ministarstva nauke Republike Srbije, br. 175061

  12. Retained gas inventory comparison

    International Nuclear Information System (INIS)

    BARTON, W.B.

    1999-01-01

    Gas volume data derived from four different analytical methods were collected and analyzed for comparison to volumes originally used in the technical basis for the Basis for Interim Operations (BIO). The original volumes came from Hodgson (1996) listed in the reference section of this document. Hodgson (1996) screened all 177 single and double-shell tanks for the presence of trapped gas in waste via two analytical methods: Surface Level Rise (SLR), and Barometric Pressure Effect (BPE). More recent gas volume projections have been calculated using different analytical techniques along with updates to the parameters used as input to the SLR and BPE models. Gas volumes derived from new analytical instruments include those as measured by the Void Fraction Instrument (VFI) and Retained Gas Sampler (RGS). The results of this comparison demonstrate that the original retained gas volumes of Hodgson (1996) used as a technical basis in developing the BIO were conservative, and were conservative from a safety analysis standpoint. These results represent only comparisons to the original reported volumes using the limited set of newly acquired data that is available

  13. Removal of Retained Adherent Placental Remnants Using the Hysteroscopy Endo-Operative System.

    Science.gov (United States)

    Zhu, Ke-An; Huang, Huan; Xue, Min; Subedi, Jigyasa; Jamail, Grace; Zhao, Weidong; Xu, Dabao; Xiao, Songshu

    2016-01-01

    Removal of retained adherent placental remnants (RAPRs) may be challenging using traditional 5Fr or 7Fr hysteroscopic grasping forceps because they are very small. This is particularly true when the retained placental remnant is large. This video demonstrates the advantages of using the Hysteroscopy Endo-Operative System (HEOS), a specially designed operative hysteroscope with a 13Fr working channel, to remove retained placental remnants. Step-by-step explanation of the technique using videos and pictures (educative video) (Canadian Task Force Classification III). Third Xiangya Hospital of Central South University, Hunan, China. A 32-year-old woman was diagnosed with RAPRs 5 weeks after the evacuation of retained placenta after a spontaneous abortion at 16 weeks' gestation. Gynecologic examination revealed an anterior 8-week uterus and no tenderness. Serum β-human chorionic gonadotropin was 150 mIU/L. Sonography revealed an irregular intrauterine mass, 3.5 cm × 3.5 cm × 3 cm in size. Removal of RAPRs using HEOS (Sopro-comeg Company, Bordeaux, France). The operation time was only 12 minutes. The RAPRs were removed completely and quickly in 1 procedure with no complications. The serum β-human chorionic gonadotropin titer normalized 1 week after the procedure. This study was approved by the institutional review board of the Third Xiangya Hospital of Central South University. When indicated, removal of RAPRs using HEOS is safe and simple because of its large and strong cold forceps. Additionally, it avoids electrical and thermal injury to the endometrium, which is particularly important in a population that wants to preserve fertility. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  14. Implant retention systems for implant-retained overdentures.

    Science.gov (United States)

    Laverty, D P; Green, D; Marrison, D; Addy, L; Thomas, M B M

    2017-03-10

    Implant retained overdentures are being increasingly utilised in both general and specialist practice to rehabilitate patients with missing teeth, particularly those that are edentate. This article aims to inform the reader of a variety of retention systems that are available to retain an implant overdenture and to understand how these systems work, their advantages and disadvantages and to outline some of the clinical and treatment planning considerations involved in selecting the most appropriate retention system for patients.

  15. Bonded versus vacuum-formed retainers: a randomized controlled trial. Part 1: stability, retainer survival, and patient satisfaction outcomes after 12 months.

    Science.gov (United States)

    Forde, Katherine; Storey, Madeleine; Littlewood, Simon J; Scott, Paul; Luther, Friedy; Kang, Jing

    2017-10-20

    There is a shortage of evidence on the best type of retainer. Evaluate upper and lower bonded retainers (BRs) versus upper and lower vacuum-formed retainers (VFRs) over 12 months, in terms of stability, retainer survival, and patient satisfaction. Two-arm parallel group multi-centre randomized controlled clinical trial. Sixty consecutive patients completing fixed appliance therapy and requiring retainers were recruited from 3 hospital departments. They were randomly allocated to either upper and lower labial segment BRs (n = 30) or upper and lower full-arch VFRs (n = 30). Primary outcome was stability. Secondary outcomes were retainer survival and patient satisfaction. A random sequence of treatment allocation was computer-generated and implemented by sealing in sequentially numbered opaque sealed envelopes independently prepared in advance. Patients, operators and outcome could not be blinded due to the nature of the intervention. Thirty patients received BRs (median [Mdn] age 16 years, inter-quartile range [IQR] = 2) and 30 received VFRs (Mdn age 17 years, IQR = 4). Baseline characteristics were similar between groups. At 12 months, there were no statistically significant inter-group differences in post-treatment change of maxillary labial segment alignment (BR = 1.1 mm, IQR = 1.56, VFR = 0.76 mm, IQR = 1.55, P = 0.61); however, there was greater post-treatment change in the mandibular VFR group (BR = 0.77 mm, IQR = 1.46, VFR = 1.69mm, IQR = 2.00, P = 0.008). The difference in maxillary retainer survival rates were statistically non-significant, P = 0.34 (BR = 63.6%, 239.3 days, 95% confidence interval [CI] = 191.1-287.5, VFR = 73.3%, 311.1 days, 95% CI = 278.3-344.29). The mandibular BR had a lower survival rate (P = 0.01) at 12 months (BR = 50%, 239.3 days 95% CI = 191.1-287.5, VFR = 80%, 324.9 days 95% CI = 295.4-354.4). More subjects with VFRs reported discomfort (P = 0.002) and speech difficulties (P = 0.004) but found them easier to clean than those with

  16. Control component retainer

    International Nuclear Information System (INIS)

    Walton, L.A.; King, R.A.

    1983-01-01

    An apparatus is described for retaining an undriven control component assembly disposed in a fuel assembly in a nuclear reactor of the type having a core grid plate. The first part of the mechanism involves a housing for the control component and the second part is a brace with a number of arms that reach under the grid plate. The brace and the housing are coupled together to firmly hold the control components in place even under strong flows of th coolant

  17. Retained gas sampler interim safety assessment

    Energy Technology Data Exchange (ETDEWEB)

    Pasamehmetoglu, K.O.; Miller, W.O.; Unal, C.; Fujita, R.K.

    1995-01-13

    This safety assessment addresses the proposed action to install, operate, and remove a Retained Gas Sampler (RGS) in Tank 101-SY at Hanford. Purpose of the RGS is to help characterize the gas species retained in the tank waste; the information will be used to refine models that predict the gas-producing behavior of the waste tank. The RGS will take samples of the tank from top to bottom; these samples will be analyzed for gas constituents. The proposed action is required as part of an evaluation of mitigation concepts for eliminating episodic gas releases that result in high hydrogen concentrations in the tank dome space.

  18. Retained gas sampler interim safety assessment

    International Nuclear Information System (INIS)

    Pasamehmetoglu, K.O.; Miller, W.O.; Unal, C.; Fujita, R.K.

    1995-01-01

    This safety assessment addresses the proposed action to install, operate, and remove a Retained Gas Sampler (RGS) in Tank 101-SY at Hanford. Purpose of the RGS is to help characterize the gas species retained in the tank waste; the information will be used to refine models that predict the gas-producing behavior of the waste tank. The RGS will take samples of the tank from top to bottom; these samples will be analyzed for gas constituents. The proposed action is required as part of an evaluation of mitigation concepts for eliminating episodic gas releases that result in high hydrogen concentrations in the tank dome space

  19. Rigidly framed earth retaining structures thermal soil structure interaction of buildings supporting unbalanced lateral earth pressures

    CERN Document Server

    Aboumoussa, Walid

    2014-01-01

    Structures placed on hillsides often present a number of challenges and a limited number of economical choices for site design. An option sometimes employed is to use the building frame as a retaining element, comprising a Rigidly Framed Earth Retaining Structure (RFERS). The relationship between temperature and earth pressure acting on RFERS, is explored in this monograph through a 4.5 year monitoring program of a heavily instrumented in service structure. The data indicated that the coefficient of earth pressure behind the monitored RFERS had a strong linear correlation with temperature. The study also revealed that thermal cycles, rather than lateral earth pressure, were the cause of failure in many structural elements. The book demonstrates that depending on the relative stiffness of the retained soil mass and that of the structural frame, the developed lateral earth pressure, during thermal expansion, can reach magnitudes several times larger than those determined using classical earth pressure theories....

  20. The effects of operating factors on the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic trout fish farm wastewater through nanofiltration

    Directory of Open Access Journals (Sweden)

    Ali Reza Solaimany Nazar

    2016-04-01

    Full Text Available An aquaculture system can be a potentially significant source of antibacterial compounds and ammonia in an aquatic environment. In this study, the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic aqueous wastewater was assessed by applying a commercial TFC (thin film composite polyamide nanofilter. The effects of pH (6.5-8.5, pressure (4-10 bar, concentration of total ammonia nitrogen (1-9 mg/L, and florfenicol (0.2-5 mg/L on the removal efficiency of the nanofilter were studied at a constant 70% recovery rate. It was found that by increasing the pH within the range of 6.5 to 8.5, it enhanced the removal efficiency by up to 98% and 100% for total ammonia nitrogen and florfenicol, respectively. With an increase in pressure from 4 to 7 bar, the removal percentage increased and then, it decreased from 7 to 10 bar. The interactions factors did not have significant effects on the both pollutants removal efficiencies. To obtain optimal removal efficiencies, an experimental design and statistical analysis via the response surface method were adopted.

  1. Probabilistic safety analysis of earth retaining structures during earthquakes

    Science.gov (United States)

    Grivas, D. A.; Souflis, C.

    1982-07-01

    A procedure is presented for determining the probability of failure of Earth retaining structures under static or seismic conditions. Four possible modes of failure (overturning, base sliding, bearing capacity, and overall sliding) are examined and their combined effect is evaluated with the aid of combinatorial analysis. The probability of failure is shown to be a more adequate measure of safety than the customary factor of safety. As Earth retaining structures may fail in four distinct modes, a system analysis can provide a single estimate for the possibility of failure. A Bayesian formulation of the safety retaining walls is found to provide an improved measure for the predicted probability of failure under seismic loading. The presented Bayesian analysis can account for the damage incurred to a retaining wall during an earthquake to provide an improved estimate for its probability of failure during future seismic events.

  2. Abdominal retained surgical sponges: CT appearance

    International Nuclear Information System (INIS)

    Kalovidouris, A.; Kehagias, D.; Moulopoulos, L.; Gouliamos, A.; Pentea, S.; Vlahos, L.

    1999-01-01

    Retention of surgical sponges is rare. They cause either an aseptic reaction without significant symptoms or an exudative reaction which results in early but nonspecific symptoms. Computed tomography is very useful for recognition of retained sponges. The appearance of retained sponges is widely variable. Air trapping into a surgical sponge results in the spongiform pattern which is characteristic but unfortunately uncommon. A low-density, high-density, or complex mass is found in the majority of cases, but these patterns are not specific. Sometimes, a thin high-density capsule may be seen. Rim or internal calcification is a rare finding. Finally, a radiopaque marker is not a reliable sign. Differentiation from abscess and hematoma is sometimes difficult. (orig.)

  3. Experimental Study of Dry Granular Flow and Impact Behavior Against a Rigid Retaining Wall

    Science.gov (United States)

    Jiang, Yuan-Jun; Towhata, Ikuo

    2013-07-01

    Shallow slope failure in mountainous regions is a common and emergent hazard in terms of its damage to important traffic routes and local communities. The impact of dry granular flows consisting of rock fragments and other particles resulting from shallow slope failures on retaining structures has yet to be systematically researched and is not covered by current design codes. As a preliminary study of the impact caused by dry granular flows, a series of dry granular impact experiments were carried out for one model of a retaining wall. It was indirectly verified that the total normal force exerted on a retaining wall consists of a drag force ( F d), a gravitational and frictional force ( F gf), and a passive earth force ( F p), and that the calculation of F d can be based on the empirical formula defined in NF EN Eurocode 1990 ( Eurocode structuraux. Base de calcul des structures, AFNOR La plaine Saint Denis, 2003). It was also indirectly verified that, for flow with Froude number from 6 to 11, the drag coefficient ( C d) can be estimated using the previously proposed empirical parameters.

  4. Academic retainer medicine: an innovative business model for cross-subsidizing primary care.

    Science.gov (United States)

    Lucier, David J; Frisch, Nicholas B; Cohen, Brian J; Wagner, Michael; Salem, Deeb; Fairchild, David G

    2010-06-01

    Retainer-medicine primary care practices, commonly referred to as "luxury" or "concierge" practices, provide enhanced services to patients beyond those available in traditional practices for a yearly retainer fee. Adoption of retainer practices has been largely absent in academic health centers (AHCs). Reasons for this trend stem primarily from ethical concerns, such as the potential for patient abandonment when physicians downsize from larger, traditional practices to smaller, retainer-medicine practices.In 2004, the Department of Medicine at Tufts Medical Center developed an academic retainer-medicine primary care practice within the Division of General Medicine that not only generates financial support for the division but also incorporates a clinical and business model that is aligned with the mission and ethics of an academic institution.In contrast to private retainer-medicine practices, this unique business model addresses several of the ethical issues associated with traditional retainer practices-it does not restrict net access to care and it neutralizes concerns about patient abandonment. Addressing the growing primary care shortage, the model also presents the opportunity for a retainer practice to cross-subsidize the expansion of general medicine in an academic medical setting. The authors elucidate the benefits, as well as the inherent challenges, of embedding an academic retainer-medicine practice within an AHC.

  5. The challenge of retaining customers acquired with free trials

    NARCIS (Netherlands)

    Datta, H.; Foubert, B.; van Heerde, H.J.

    Many service firms acquire customers by offering free-trial promotions. A crucial challenge is to retain customers acquired with these free trials. To address this challenge, firms need to understand how free-trial customers differ from regular customers in terms of their decision making to retain

  6. Effects of Geofoam Panels on Static Behavior of Cantilever Retaining Wall

    Directory of Open Access Journals (Sweden)

    Navid Hasanpouri Notash

    2018-01-01

    Full Text Available Geofoam is one of the geosynthetic products that can be used in geotechnical applications. According to researches, expanded polystyrene (EPS geofoam placed directly against a rigid retaining wall has been proposed as a strategy to reduce static loads on the wall. This study employed a finite difference analysis using a 2-D FLAC computer program by considering yielding and nonyielding states for retaining walls to explore the effectiveness of geofoam panels in improving the static performance of cantilever retaining walls. Retaining walls at heights of 3, 6, and 9 meters and geofoam panels with densities of 15, 20, and 25 (kg/m3 at three relative thicknesses of t/H = 0.05, 0.2, and 0.4 were modelled in this numerical study. In addition, the performance of the double EPS buffer system, which involves two vertical geofoam panels, in retaining walls’ stability with four panel spacing (50, 100, 150, and 200 cm was also evaluated in this research. The results showed that use of EPS15 with density equal to 15 (kg/m3 which has the lowest density among other geofoam panels has a significant role in reduction of lateral stresses, although the performance of geofoam in nonyielding retaining walls is better than yielding retaining walls.

  7. Evaluation of stress patterns produced by implant-retained overdentures and implant-retained fixed partial denture.

    Science.gov (United States)

    Mazaro, José Vitor Quinelli; Filho, Humberto Gennari; Vedovatto, Eduardo; Pellizzer, Eduardo Piza; Rezende, Maria Cristina Rosifini Alves; Zavanelli, Adriana Cristina

    2011-11-01

    The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 × 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

  8. Effectiveness of Horizontal Rebar on Concrete Block Retaining Wall Strength

    OpenAIRE

    Krishpersad Manohar; Rikhi Ramkissoon

    2016-01-01

    The effectiveness of including a horizontal rebar compared to only a vertical rebar in concrete filled core interlocking concrete block retaining wall sections was investigated with respect to the horizontal retaining force. Experimental results for three specimens of interlocking blocks with vertical rebar and concrete filled cores showed an average horizontal retaining force of 24546 N ± 5.7% at an average wall deflection of 13.3 mm. Experimental results for three wall specimens of interloc...

  9. Abdominal retained surgical sponges: CT appearance

    Energy Technology Data Exchange (ETDEWEB)

    Kalovidouris, A.; Kehagias, D.; Moulopoulos, L.; Gouliamos, A.; Pentea, S.; Vlahos, L. [Department of Radiology, University of Athens (Greece)

    1999-09-01

    Retention of surgical sponges is rare. They cause either an aseptic reaction without significant symptoms or an exudative reaction which results in early but nonspecific symptoms. Computed tomography is very useful for recognition of retained sponges. The appearance of retained sponges is widely variable. Air trapping into a surgical sponge results in the spongiform pattern which is characteristic but unfortunately uncommon. A low-density, high-density, or complex mass is found in the majority of cases, but these patterns are not specific. Sometimes, a thin high-density capsule may be seen. Rim or internal calcification is a rare finding. Finally, a radiopaque marker is not a reliable sign. Differentiation from abscess and hematoma is sometimes difficult. (orig.) With 11 figs., 12 refs.

  10. Treatment of retained placenta with misoprostol: a randomised controlled trial in a low-resource setting (Tanzania

    Directory of Open Access Journals (Sweden)

    Fauteck Heiner

    2009-10-01

    Full Text Available Abstract Background Retained placenta is one of the common causes of maternal mortality in developing countries where access to appropriate obstetrical care is limited. Current treatment of retained placenta is manual removal of the placenta under anaesthesia, which can only take place in larger health care facilities. Medical treatment of retained placenta with prostaglandins E1 (misoprostol could be cost-effective and easy-to-use and could be a life-saving option in many low-resource settings. The aim of this study is to assess the efficacy and safety of sublingually administered misoprostol in women with retained placenta in a low resource setting. Methods Design: Multicentered randomised, double-blind, placebo-controlled trial, to be conducted in 5 hospitals in Tanzania, Africa. Inclusion criteria: Women with retained placenta, at a gestational age of 28 weeks or more and blood loss less than 750 ml, 30 minutes after delivery of the newborn despite active management of third stage of labour. Trial Entry & Randomisation & Study Medication: After obtaining informed consent, eligible women will be allocated randomly to the treatment groups using numbered envelopes that will be randomized in variable blocks containing identical capsules with either 800 microgram of misoprostol or placebo. The drugs will be given sublingually. The women, maternal care providers and researchers will be blinded to treatment allocation. Sample Size: 117 women, to show a 40% reduction in manual removals of the placenta (p = 0.05, 80% power. The randomization will be misoprostol: placebo = 2:1 Primary Study Outcome: Expulsion of the placenta without manual removal. Secondary outcome is the number of blood transfusions. Discussion This is a protocol for a randomized trial in a low resource setting to assess if medical treatment of women with retained placenta with misoprostol reduces the incidence of manual removal of the placenta. Clinical Trial Registration Current

  11. Customized versus Patient-Sized Cruciate-Retaining Total Knee Arthroplasty: An In Vivo Kinematics Study Using Mobile Fluoroscopy.

    Science.gov (United States)

    Zeller, Ian M; Sharma, Adrija; Kurtz, William B; Anderle, Mathew R; Komistek, Richard D

    2017-04-01

    Historically, knee arthroplasties have been designed using average patient anatomy. Recent advances in imaging and manufacturing have facilitated the development of customized prostheses designed to fit the unique shape of individual patients. The purpose of this study is to determine if improving implant design through customized total knee arthroplasty (TKA) improves kinematic function. Using state-of-the-art mobile fluoroscopy, tibiofemoral kinematics were analyzed for 24 subjects with a customized individually made (CIM), cruciate-retaining TKA, and 14 subjects having an asymmetric condylar cruciate-retaining TKA. Subjects performed a weight-bearing deep knee bend and a rise from a seated position. Each patient was evaluated for weight-bearing range of motion, femorotibial translation, femorotibial axial rotation, and condylar liftoff occurrence. Subjects having a CIM TKA experienced greater weight-bearing knee flexion compared with the traditional posterior cruciate-retaining (PCR) TKA design. During flexion, the CIM TKA subjects consistently exhibited more posterior femoral rollback than the traditional PCR TKA subjects. The CIM TKA was found to have statistically greater axial rotation compared with the traditional PCR TKA (P = .05). Of note, only the CIM TKA patients experienced femoral internal rotation at full extension, as exhibited in a normal knee. Compared with the traditional PCR TKA, the CIM TKAs demonstrated minimal occurrences of paradoxical sliding and reverse rotation during flexion and extension. The CIM TKA subjects showed minimal liftoff and hence better stability in earlyflexion to midflexion compared with the traditional PCR subjects. The CIM TKA demonstrated kinematics more similar to a normal knee. Therefore, using customized implant technology through CIM TKA designs affords benefits including more normal motion compared with a traditional PCR TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Dust retaining properties of leaves of some tree species

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, M I

    1960-05-01

    A study was made in Tashkent, Russia of the dust-retaining power of leaves of several tree species. Investigations were made in a park where these tree species were growing in close proximity, exposed to the effects of dust from the main city street and from the highway passing through the park. Observations on the dust-retaining power of leaves were made mostly during the summer and fall months. The dust-retaining power of leaves of different tree species varied with the dust concentration in the air. In the summer and fall when rains are scarce a steady accumulation of dust was observed on the surface of the leaves. 1 table.

  13. Recruiting and Retaining Army Nurses: An Annotated Bibliography

    OpenAIRE

    Roberts, Benjamin J.; Kocher, Kathryn M.

    1988-01-01

    This listing of annotated references includes studies dealing with the labor market behavior of registered nurses. References describing both the military and the civilian working environments for RNs are contained in the bibliography. Because the Army must recruit and retain nurses in the context of the national labor market for nurses, a broad perspective was maintained in selecting publication. Studies dealing with the factors influential in attracting and retaining Army Active Duty and Re...

  14. A systematic review of the clinical performance of tooth-retained and implant-retained double crown prostheses with a follow-up of ≥ 3 years.

    Science.gov (United States)

    Verma, Rohini; Joda, Tim; Brägger, Urs; Wittneben, Julia-Gabriela

    2013-01-01

    The objective of this review was to systematically screen the literature for data related to the survival and complication rates observed with dental or implant double crown abutments and removable prostheses under functional loading for at least 3 years. A systematic review of the dental literature from January 1966 to December 2009 was performed in electronic databases (PubMed and Embase) as well as by an extensive hand search to investigate the clinical outcomes of double crown reconstructions. From the total of 2412 titles retrieved from the search, 65 were selected for full-text review. Subsequently, 17 papers were included for data extraction. An estimation of the cumulative survival and complication rates was not feasible due to the lack of detailed information. Tooth survival rates for telescopic abutment teeth ranged from 82.5% to 96.5% after an observation period of 3.4 to 6 years, and for tooth-supported double crown retained dentures from 66.7% to 98.6% after an observation period of 6 to 10 years. The survival rates of implants were between 97.9% and 100% and for telescopic-retained removable dental prostheses with two mandibular implants, 100% after 3.0 and 10.4 years. The major biological complications affecting the tooth abutments were gingival inflammation, periodontal disease, and caries. The most frequent technical complications were loss of cementation and loss of facings. The main findings of this review are: (I) double crown tooth abutments and dentures demonstrated a wide range of survival rates. (II) Implant-supported mandibular overdentures demonstrated a favorable long-term prognosis. (III) A greater need for prosthetic maintenance is required for both tooth-supported and implant-supported reconstructions. (IV) Future areas of research would involve designing appropriate longitudinal studies for comparisons of survival and complication rates of different reconstruction designs. © 2012 by the American College of Prosthodontists.

  15. Incidence and outcome of retained Port-A-Cath fragments during removal.

    Science.gov (United States)

    Aworanti, Olugbenga Michael; Linnane, Niall; Tareen, Farhan; Mortell, Alan

    2017-07-01

    Port-A-Cath devices are frequently used for long-term venous access. We postulate that long-term use predisposes them to getting stuck and retained in a central vein at the time of removal. We aim to report the incidence and outcome of this complication. Between January 2006 and July 2016, a retrospective review of all Port-A-Cath removals that were performed at our centre was conducted. At the time of removal, catheters that could not be removed from the vein were considered retained. During the study period, 107 children had 174 episodes of silicone Sitimplant (Vygon, Ecouen, France) Port-A-Cath insertions. These children required 135 removal episodes and there were 3 (2.2%) instances whereby the catheter fragment was retained. These episodes of retained catheters only occurred in children with factor VIII deficiency (4.1% incidence in this cohort). For each episode of catheter insertion and removal, the catheters had been left in situ for a mean duration of 43 months in children with factor deficiency and no retained fragments, and the mean duration was 91 months in children with factor deficiency and retained catheter fragments (p = 0.0011). Port-A-Caths that are retained after attempted removal is a complication encountered predominantly in catheters that have been in use for a prolonged duration. Furthermore, factor replacement therapy in haemophiliacs may be a risk factor for this complication.

  16. Migration of innumerable chronically retained acupuncture needles

    Directory of Open Access Journals (Sweden)

    Frances Lazarow, MD

    2017-09-01

    Full Text Available We present a case of a 50-year-old female with a 2-day history of back and abdominal pain who was discovered to have innumerable chronically retained acupuncture needles, which had migrated throughout her abdomen and pelvis. Although many of these needles were in precarious positions, including the epidural space, renal parenchyma, small bowel, and vasculature, there was no evidence for acute injury. We also briefly discuss evidence for the magnetic resonance imaging compatibility of acupuncture needles. Although a rare complication, given the high frequency of acupuncture therapy in the United States, physicians must be aware of the potential for retained and migrated needles.

  17. ORGANIZING, TRAINING, AND RETAINING INTELLIGENCE PROFESSIONALS FOR CYBER OPERATIONS

    Science.gov (United States)

    2016-02-13

    in Education,” Preventing School Failure 57(3), (2013): 162-170. Wall , Andru, “Demystifying the Title 10-Title 50 Debate,” Harvard Law School...AIR WAR COLLEGE AIR UNIVERSITY ORGANIZING, TRAINING, AND RETAINING INTELLIGENCE PROFESSIONALS FOR CYBER OPERATIONS by Melissa A...to adequately organize, train and retain cyber expertise. This is especially true within Air Force intelligence, a critical component of the

  18. Lead poisoning from retained bullets: pathogenesis, diagnosis, and management

    International Nuclear Information System (INIS)

    Linden, M.A.; Manton, W.I.; Stewart, R.M.; Thal, E.R.; Feit, H.

    1982-01-01

    Lead intoxication (plumbism) from retained bullets has rarely been reported but may be fatal if unrecognized. Bullets lodged within joint spaces or pseudocysts are more likely to develop this complication, although patients with retained missiles in other locations may also be at risk. Subtle findings such as the occurrence of unexplained anemia, abdominal colic, nephropathy, or neurologic deterioration in patients with retained missiles may suggest consideration of plumbism. An intercurrent metabolic stress such as infection, endocrinopathy, or alcoholism may be a precipitating factor. Among the various diagnostic studies available, mass spectrometric stable isotope dilution analysis may be the most reliable. It is important to employ chelation therapy prior to any operative intervention. This will reduce the mobilization of lead from bone during or following the surgical procedure

  19. Accelerated aging effects on surface hardness and roughness of lingual retainer adhesives.

    Science.gov (United States)

    Ramoglu, Sabri Ilhan; Usumez, Serdar; Buyukyilmaz, Tamer

    2008-01-01

    To test the null hypothesis that accelerated aging has no effect on the surface microhardness and roughness of two light-cured lingual retainer adhesives. Ten samples of light-cured materials, Transbond Lingual Retainer (3M Unitek) and Light Cure Retainer (Reliance) were cured with a halogen light for 40 seconds. Vickers hardness and surface roughness were measured before and after accelerated aging of 300 hours in a weathering tester. Differences between mean values were analyzed for statistical significance using a t-test. The level of statistical significance was set at P statistically significant (P statistically significant (P .05). Accelerated aging significantly increased the surface microhardness of both light-cured retainer adhesives tested. It also significantly increased the surface roughness of the Transbond Lingual Retainer.

  20. Development of ultrasonic inspection technique for crack detection in retaining rings

    International Nuclear Information System (INIS)

    Brook, M.V.

    1990-01-01

    The majority of retaining rings which are currently in service, are composed of a material which is susceptible to stress corrosion when exposed to moisture. Due to the inherent stress levels in the shrunk-on areas, they are particularly susceptible to stress corrosion attack. Therefore, retaining rings require non-destructive examination to avert catastrophic failure. Guidelines for retaining ring inspection issued by EPRI recommend ultrasonic manual and automated methods of inspection for rings in place. Application of the conventional manual method, using S-waves is difficult, and yields unreliable results. Due to the unreliability factor, utilities have been forced to depend upon surface examination methods, such as visual and penetrant techniques. In most instances, a surface exam will necessitate the costly and potentially damaging removal of the rings from the rotor to provide full access to areas of interest. Due to the various complexities of conventional ultrasonic retaining ring inspections, it is essential that the front end ultrasonics (i.e., transducers and techniques) be optimized to produce the best possible examination. For this reason, AMDATA has developed custom transducers and techniques to enhance automated detection capability of flaws in the various suspect areas of retaining rings. When the optimized techniques are applied to generate the best possible raw data, the Intraspect /98 trademark is then used to reliably apply technique, acquire the data and perform post processing evaluations. One of the most promising ultrasonic techniques for retaining ring inspection is creeping waves. This paper investigates the use of creeping waves for retaining ring inspection

  1. Inspection of rotor bores, retaining rings and turbine discs utilizing UDRPS

    International Nuclear Information System (INIS)

    Quinn, J.R.

    1990-01-01

    New construction in the U.S. utility industry is at a very low level. The average age of plants in increasing almost linearly with time, many units will pass nominal end of life in the next decade. Planned new construction now takes ten years to effect at a minimum. The need for more reliable inspection of high stress utility components is and will continue to be a subject of increased emphasis. Dynacon Systems Inc. has recently introduced into commercial service, a fully automated ultrasonic inspection instrumentation package designed to significantly increase the reliability of turbine/generator rotor shaft, LP disc and generator retaining ring inspections. The package is designed to automate to a very high degree, the entire analysis process, thus eliminating operator error sources. The automated process begins at the ultrasonic pulse generator and ends with the input to fracture mechanics analysis

  2. Veneered zirconia inlay-retained fixed dental prostheses: 10-Year results from a prospective clinical study.

    Science.gov (United States)

    Rathmann, Friederike; Bömicke, Wolfgang; Rammelsberg, Peter; Ohlmann, Brigitte

    2017-09-01

    The purpose of this study was to evaluate the 10-year clinical performance of zirconia-based inlay-retained fixed dental prostheses (IRFDP). For replacement of a molar in 27 patients, 30 IRFDP were luted by use of different cements, Panavia F (Kuraray Europe GmbH) or Multilink Automix (Ivoclar Vivadent GmbH), with use of inlay/inlay, inlay/full-crown, or inlay/partial-crown retainers for anchorage. Frameworks were milled from yttria-stabilized zirconia (IPS e.maxZirCAD; Ivoclar Vivadent GmbH) and fully veneered with pressable ceramic (IPS e.max ZirPress; Ivoclar Vivadent GmbH). Before luting, the IRFDP were silica-coated (Rocatec; 3M Espe) and silanized (Monobond S; Ivoclar Vivadent GmbH). Complications (for example, chipping or delamination of the veneering ceramic, debonding, secondary caries, endodontic treatment, and abutment tooth fracture) and failure were reported, by use of standardized report forms, 2 weeks, 6 months, and 1, 2, and 10 years after cementation. Statistical analysis included Kaplan-Meier survival and success (complication-free survival) and Cox regression analysis (α=0.05 for all). During the 10-year observation period, the complications most often observed were chipping of the veneer and debonding. Twenty-five restorations failed and one participant dropped out. Cumulative 10-year survival and success were 12.1% and 0%, respectively. The design of the retainer, use of a dental dam, choice of cement, and location in the dental arch had no statistically significant effect on the occurrence of complications. Use of fully veneered zirconia-based IRFDP with this technique cannot be recommended. A large incidence of complications and poor survival were observed for fully veneered zirconia-based IRFDP, revealing an urgent need for further design improvements for this type of restoration. This, again, emphasizes the need for testing of new restoration designs in clinical trials before implementation in general dental practice. Copyright © 2017

  3. Economic and reproductive consequences of retained placenta in dairy cattle.

    NARCIS (Netherlands)

    Joosten, I.; Stelwagen, J.; Dijkhuizen, A.A.

    1988-01-01

    The financial losses due to retained placenta in Dutch dairy cattle were estimated by using two different methods of calculation. A data-set containing the birth records of 160,188 Meuse-Rhine-Yssel cows provided data on the reproductive performance of cows with and without retained placenta. The

  4. Total rewards that retain: A study of demographic preferences

    OpenAIRE

    Monica Pregnolato; Mark H.R. Bussin; Anton F. Schlechter

    2017-01-01

    Orientation: Changing workplace demographics and a dearth of employees with scarce skills have forced employers to better understand the various factors that retain talented employees. Research purpose: In this empirical study, the reward preferences and ideal combination of total reward elements (based on an estimation of their relative importance) that retain employees from various demographic groups, including employees of different race, gender and age groups, were investigated. M...

  5. Attachment retained overdentures: a report on their maintenance requirements.

    Science.gov (United States)

    Shaw, M J

    1984-07-01

    Twenty-three patients who received attachment retained overdentures between 1964 and 1977 are reviewed. One third of the patients examined had carious abutment teeth, oral hygiene was poor, and periodontal disease prevalent. Overdentures opposed by natural teeth required more extensive prosthetic maintenance than overdentures opposed by a conventional complete denture. Three quarters of the teeth retaining the prostheses were functioning adequately after a mean period of 7 years.

  6. 17 CFR 300.304 - Retained rights of brokers or dealers.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Retained rights of brokers or... Completion of Open Contractual Commitments § 300.304 Retained rights of brokers or dealers. (a) Nothing stated in these rules shall be construed to prejudice the right of a broker or dealer to any claim...

  7. Diffraction study of the retained austenite content in TRIP steels

    Energy Technology Data Exchange (ETDEWEB)

    Gnaeupel-Herold, T., E-mail: tg-h@nist.gov [NIST Center for Neuron Research, 100 Bureau Dr., Gaithersburg MD 20899-6102 (United States); University of Maryland, Department of Material Science and Engineering., College Park MD 20742-2142 (United States); Creuziger, A., E-mail: adam.creuziger@nist.gov [NIST Metallurgy Division, 100 Bureau Dr., Gaithersburg MD 20899-8553 (United States); Kent State University, Kent, OH 44242 (United States)

    2011-04-25

    Research highlights: {yields} Novel orientation averaging scheme for retained austenite content measurement. {yields} assumption of random grain orientation generally not justified. {yields} Averaging scheme allows to disregard texture. {yields} unlike Rietveld method, averaging method does not orientation density function. {yields} Two independent (hkl) are necessary for retained austenite content. - Abstract: The results of a study of using neutron diffraction for determining the retained austenite content of TRIP steels are presented. The study covers a wide area of materials, deformation modes (uniaxial, biaxial and plane strain), strains, and the retained austenite content as a result of these variables. It was determined using basic principles of statistics that a minimum of two reflections (hkl) for each phase is necessary to calculate a phase mass fraction and the associated standard deviation. Texture from processing the steel is the largest source of uncertainty. Through the method of complete orientation averaging described in this paper, the texture effect and with it the standard deviation of the austenite mass fraction can be substantially reduced, regardless of the type or severity of the texture.

  8. Management of Retained Genital Piercings: A Case Report and Review

    Directory of Open Access Journals (Sweden)

    Laura J. Moulton

    2017-01-01

    Full Text Available The prevalence of genital piercing among women is increasing. As the popularity increases, the number of complications from infection, injury, and retained jewelry is likely to rise. Techniques to remove embedded jewelry are not well described in the literature. The purpose of this report was to describe a case of a patient with a retained clitoral glans piercing, discuss a simple technique for outpatient removal, and review current evidence regarding associated risks of clitoral piercings. A 24-year-old female presented to the emergency department with an embedded clitoral glans piercing. Local anesthetic was injected into the periclitoral skin and a small superficial vertical incision was made to remove the ball of the retained barbell safely. In conclusion, among patients with retained genital piercing, outpatient removal of embedded jewelry is feasible. While the practice of female genital piercing is not regulated, piercing of the glans of the clitoris is associated with increased injury to the nerves and blood supply of the clitoris structures leading to future fibrosis and diminished function compared to piercing of the clitoral hood.

  9. Management of Retained Genital Piercings: A Case Report and Review.

    Science.gov (United States)

    Moulton, Laura J; Jernigan, Amelia M

    2017-01-01

    The prevalence of genital piercing among women is increasing. As the popularity increases, the number of complications from infection, injury, and retained jewelry is likely to rise. Techniques to remove embedded jewelry are not well described in the literature. The purpose of this report was to describe a case of a patient with a retained clitoral glans piercing, discuss a simple technique for outpatient removal, and review current evidence regarding associated risks of clitoral piercings. A 24-year-old female presented to the emergency department with an embedded clitoral glans piercing. Local anesthetic was injected into the periclitoral skin and a small superficial vertical incision was made to remove the ball of the retained barbell safely. In conclusion, among patients with retained genital piercing, outpatient removal of embedded jewelry is feasible. While the practice of female genital piercing is not regulated, piercing of the glans of the clitoris is associated with increased injury to the nerves and blood supply of the clitoris structures leading to future fibrosis and diminished function compared to piercing of the clitoral hood.

  10. Fractures Due to Gunshot Wounds: Do Retained Bullet Fragments Affect Union?

    Science.gov (United States)

    Riehl, John T; Connolly, Keith; Haidukewych, George; Koval, Ken

    2015-01-01

    Many types of projectiles, including modern hollow point bullets, fragment into smaller pieces upon impact, particularly when striking bone. This study was performed to examine the effect on time to union with retained bullet material near a fracture site in cases of gunshot injury. All gunshot injuries operatively treated with internal fixation at a Level 1 Trauma Center between March 2008 and August 2011 were retrospectively reviewed. Retained bullet load near the fracture site was calculated based on percentage of material retained compared to the cortical diameter of the involved bone. Analyses were performed to assess the effect of the lead-cortical ratio and amount of comminution on time to fracture union. Thirty-two patients (34 fractures) met the inclusion criteria, with an equal number of comminuted (17) and non-comminuted fractures (17). Seventeen of 34 fractures (50%) united within 4 months, 16/34 (47%) developed a delayed union, and 1/34 (3%) developed a nonunion requiring revision surgery. Sixteen of 17 fractures (94%) that united by 4 months had a cumulative amount of bullet fragmentation retained near the fracture site of less than 20% of the cortical diameter. Nine out of 10 fractures (90%) with retained fragments near the fracture site was equal to or exceeding 20% of the cortical diameter had delayed or nonunion. Fracture comminution had no effect on time to union. The quantity of retained bullet material near the fracture site was more predictive of the rate of fracture union than was comminution. Fractures with bullet fragmentation equal to or exceeding 20% of the cortical width demonstrated a significantly higher rate of delayed union/nonunion compared to those fractures with less retained bullet material, which may indicate a local cytotoxic effect from lead on bone healing. These findings may influence decisions on timing of secondary surgeries. Level III.

  11. A Two-Pronged Approach to Retaining Millennial Nurses.

    Science.gov (United States)

    Koppel, Jenna; Deline, Marisa; Virkstis, Katherine

    2017-12-01

    Despite increased staff engagement and improved new hire on-boarding, organizations struggle to retain millennial nurses. One dominant trait is shared by organizations that have successfully reduced turnover for this group: investment in select strategies that cement loyalty to the organization. In this article, the authors describe 2 strategies for retaining early-tenure millennial nurses. In the 1st article of this series, the authors described why nursing leaders must supplement their organization's current investments in engagement with strategies targeted at millennials in their 1st 3 years. This 2nd part of the series will outline these strategies.

  12. Influence of cement film thickness on the retention of implant-retained crowns.

    Science.gov (United States)

    Mehl, Christian; Harder, Sönke; Steiner, Martin; Vollrath, Oliver; Kern, Matthias

    2013-12-01

    The main goal of this study was to establish a new, high precision procedure to evaluate the influence of cement film thickness on the retention of cemented implant-retained crowns. Ninety-six tapered titanium abutments (6° taper, 4.3 mm diameter, Camlog) were shortened to 4 mm. Computer-aided design was used to design the crowns, and selective laser sintering, using a cobalt-chromium alloy, was used to produce the crowns. This method used a focused high-energy laser beam to fuse a localized region of metal powder to build up the crowns gradually. Before cementing, preset cement film thicknesses of 15, 50, 80, or 110 μm were established. Glass ionomer, polycarboxylate, or resin cements were used for cementation. After 3 days storage in demineralized water, the retention of the crowns was measured in tension using a universal testing machine. The cement film thicknesses could be achieved with a high level of precision. Interactions between the factors cement and cement film thickness could be found (p ≤ 0.001). For all cements, crown retention decreased significantly between a cement film thickness of 15 and 50 μm (p ≤ 0.001). At 15 μm cement film thickness, the resin cement was the most retentive cement, followed by the polycarboxylate and then the glass ionomer cement (p ≤ 0.05). The results suggest that cement film thickness has an influence on the retentive strength of cemented implant-retained crowns. © 2013 by the American College of Prosthodontists.

  13. The use of implants as retainers for removable partial dentures.

    Science.gov (United States)

    Zinner, Ira D; Markovits, Stanley; Jansen, Curtis E; Reid, Patrick E; Shapiro, Herbert J

    2010-01-01

    There has been little presented in the literature regarding the use of implant bodies as retainers for removable partial dentures. However, these fixtures can be a useful asset for restorative dentists, as they can be used when there is insufficient bone for a fixed prosthesis or as retainers for a provisional appliance until additional dental treatment is possible.

  14. [Conventional retaining of removable partial dentures

    NARCIS (Netherlands)

    Keltjens, H.M.A.M.; Witter, D.J.; Creugers, N.H.J.

    2009-01-01

    Mechanical and biological criteria have to be met in retaining the metal frame of a removable partial denture. Additionally, a removable partial denture is part of the occlusal interface by the clasps and the denture teeth. With respect to mechanical aspects, all rigid parts of the removable partial

  15. Maxillary overdentures retained by splinted and unsplinted implants : A retrospective study

    NARCIS (Netherlands)

    Narhi, TO; Hevinga, M; Voorsmit, RACA; Kalk, W

    2001-01-01

    The purpose of this retrospective study was to evaluate the clinical performance of and patients' satisfaction with maxillary overdentures retained by splinted and unsplinted implants. Patients who had been treated with maxillary implant-retained overdentures because of functional problems with

  16. Product design and development engineering

    International Nuclear Information System (INIS)

    Lee, Kookhwan

    2008-01-01

    This book gives design of molded plastics, design of press product, design of die casting products, the application of communication terminal design, application and design of machine elements(screw, spring, bearing, gear, retaining ridge, drawing standards, KS and JIS material marks list), 3D CAD, concurrent engineering of product design, creative concept design.

  17. Long-term effectiveness of canine-to-canine bonded flexible spiral wire lingual retainers

    NARCIS (Netherlands)

    Renkema, Anne-Marie; Renkema, Alianne; Bronkhorst, Ewald; Katsaros, Christos

    Introduction: The flexible spiral wire (FSW) canine-to-canine lingual retainer bonded to all 6 anterior teeth is a frequently used type of mandibular fixed retainer. This study aimed to assess the long-term effectiveness of FSW canine-to-canine lingual retainers in maintaining the alignment of the

  18. Long-term effectiveness of canine-to-canine bonded flexible spiral wire lingual retainers

    NARCIS (Netherlands)

    Renkema, A.M.; Bronkhorst, E.M.; Katsaros, C.

    2011-01-01

    INTRODUCTION: The flexible spiral wire (FSW) canine-to-canine lingual retainer bonded to all 6 anterior teeth is a frequently used type of mandibular fixed retainer. This study aimed to assess the long-term effectiveness of FSW canine-to-canine lingual retainers in maintaining the alignment of the

  19. Macroscopic and histological characteristics of retained placenta: A prospectively collected case-control study.

    Science.gov (United States)

    Endler, Margit; Saltvedt, Sissel; Papadogiannakis, Nikos

    2016-05-01

    Retained placenta is a potentially fatal obstetric disorder due to postpartum hemorrhage, its pathophysiology is however unknown. We aimed to assess if retained placenta was associated with increased macroscopic and histological signs of placental maternal underperfusion, a pattern otherwise seen in preeclampsia and other disorders of defective placentation. This was a case-control study of retained (n = 49) and non-retained (n = 47) placentas, collected from full-term singleton and otherwise healthy pregnancies, carried out at a tertiary level obstetric department. Macroscopic and histological analysis was performed. Signs of maternal placental underperfusion and signs of placental inflammation, fetal vascular thrombo-occlusive disease and increased placental attachment were recorded in a primary and secondary analysis respectively. Variables were compared groupwise using unconditional logistic regression or comparison of median or mean values. Compared to non-retained placentas retained placentas had a significantly smaller surface area (p = 0.05), were more oblong in shape (OR 5.24 95% CI:1.34-20.21) and showed overall more signs of maternal underperfusion (OR 2.52 95% CI: 1.07-5.87). There was no significant difference in signs of placental inflammation, fetal vascular thrombo-occlusive disease or placenta accreta but basal plate myometrial fibers were more common among retained placentas. In regard to shape, surface area and histological signs of maternal placental underperfusion, retained placentas showed a histological pattern similar to that seen in preeclamptic placentas. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Placemaking: Attracting and Retaining Today's Students

    Science.gov (United States)

    Knight, Brent

    2016-01-01

    Research suggests that the appearance of a college campus--both inside and out--is a significant criterion in college selection. As community colleges are finding it increasingly important to attract and retain students, placemaking is becoming an effective and efficient platform to support recruitment and retention. Placemaking is imagining and…

  1. Disc-retained tubes for radiologically inserted gastrostomy (RIG): Not up to the job?

    International Nuclear Information System (INIS)

    Kibriya, N.; Wilbraham, L.; Mullan, D.; Puro, P.; Vasileuskaya, S.; Edwards, D.W.; Laasch, H.-U.

    2013-01-01

    Aim: To assess the insertion procedure and performance of disc-retained gastrostomy tubes, recording complications and accidental displacements by prospective audit, and to determine whether primary placement of the tube off-licence was feasible. Materials and methods: Disc-retained 12 F single-lumen Monarch gastrostomy tubes (Enteral UK, Selby, UK) were inserted by three gastrointestinal interventional radiologists in a supra-regional cancer centre. The 12 F tubes required a 20 F peel-away sheath with four-point gastropexy fixation and were placed under conscious sedation, using electrocardiogram (EEG) bispectral index monitoring. Follow-up was performed in an in-house gastrostomy drop-in clinic at 1 week and 1 month, supplemented with weekly telephone follow-up. Patients also had open access to the gastrostomy drop-in clinic for immediate advice and complication management. Results: Eighteen patients underwent primary insertion of a Monarch gastrostomy tube over 5 months. A total of 6/18 (33%) tubes displaced; 4/18 (22%) completely, 2/18 (11%) occult into the peritoneum. Four of 18 (22%) patients developed infection at the stoma site. Due to the unexpectedly poor performance of the tube, the study was terminated early. Conclusion: Initial experience with the Monarch disc-retained gastrostomy tube demonstrates it unsuitable for primary placement with current protocols. In view of the potentially serious complications, the Medicines and Healthcare Products Regulatory Agency (MHRA) has been informed. A request has been made to the distributer to reassess the tube design and/or review the procedure promoted for primary placement

  2. Risk factors for cardiovascular disease and type 2 diabetes retained from childhood to adulthood predict adult outcomes: the Princeton LRC Follow-up Study

    Directory of Open Access Journals (Sweden)

    Morrison John A

    2012-04-01

    Full Text Available Abstract Background Pediatric risk factors predict adult cardiovascular disease (CVD and type 2 diabetes (T2DM, but whether they predict events independently of adult risk factors is not fully known. Objective Assess whether risk factors for CVD and T2DM retained from childhood to adulthood predict CVD and T2DM in young adulthood. Study design 770 schoolchildren, ages 5–20 (mean age 12, 26-yr prospective follow-up. We categorized childhood and adult risk factors and 26-year changes (triglycerides [TG], LDL cholesterol, BMI, blood pressure [BP] and glucose ≥, and HDL cholesterol Results Children who had high TG and retained high TG as adults had increased CVD events as adults (p = .0005. Children who had normal BMI and retained normal BMI as adults had reduced CVD events as adults (p = .02. Children who had high BP or high TG and retained these as adults had increased T2DM as adults (p = .0006, p = .003. Conclusions Risk factors for CVD and T2DM retained from childhood to adulthood predict CVD and T2DM in young adulthood and support universal childhood screening.

  3. Retained Austenite in SAE 52100 Steel Post Magnetic Processing and Heat Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Pappas, Nathaniel R [ORNL; Watkins, Thomas R [ORNL; Cavin, Odis Burl [ORNL; Jaramillo, Roger A [ORNL; Ludtka, Gerard Michael [ORNL

    2007-01-01

    Steel is an iron-carbon alloy that contains up to 2% carbon by weight. Understanding which phases of iron and carbon form as a function of temperature and percent carbon is important in order to process/manufacture steel with desired properties. Austenite is the face center cubic (fcc) phase of iron that exists between 912 and 1394 C. When hot steel is rapidly quenched in a medium (typically oil or water), austenite transforms into martensite. The goal of the study is to determine the effect of applying a magnetic field on the amount of retained austenite present at room temperature after quenching. Samples of SAE 52100 steel were heat treated then subjected to a magnetic field of varying strength and time, while samples of SAE 1045 steel were heat treated then subjected to a magnetic field of varying strength for a fixed time while being tempered. X-ray diffraction was used to collect quantitative data corresponding to the amount of each phase present post processing. The percentage of retained austenite was then calculated using the American Society of Testing and Materials standard for determining the amount of retained austenite for randomly oriented samples and was plotted as a function of magnetic field intensity, magnetic field apply time, and magnetic field wait time after quenching to determine what relationships exist with the amount of retained austenite present. In the SAE 52100 steel samples, stronger field strengths resulted in lower percentages of retained austenite for fixed apply times. The results were inconclusive when applying a fixed magnetic field strength for varying amounts of time. When applying a magnetic field after waiting a specific amount of time after quenching, the analyses indicate that shorter wait times result in less retained austenite. The SAE 1045 results were inconclusive. The samples showed no retained austenite regardless of magnetic field strength, indicating that tempering removed the retained austenite. It is apparent

  4. Seismic analysis for translational failure of landfills with retaining walls.

    Science.gov (United States)

    Feng, Shi-Jin; Gao, Li-Ya

    2010-11-01

    In the seismic impact zone, seismic force can be a major triggering mechanism for translational failures of landfills. The scope of this paper is to develop a three-part wedge method for seismic analysis of translational failures of landfills with retaining walls. The approximate solution of the factor of safety can be calculated. Unlike previous conventional limit equilibrium methods, the new method is capable of revealing the effects of both the solid waste shear strength and the retaining wall on the translational failures of landfills during earthquake. Parameter studies of the developed method show that the factor of safety decreases with the increase of the seismic coefficient, while it increases quickly with the increase of the minimum friction angle beneath waste mass for various horizontal seismic coefficients. Increasing the minimum friction angle beneath the waste mass appears to be more effective than any other parameters for increasing the factor of safety under the considered condition. Thus, selecting liner materials with higher friction angle will considerably reduce the potential for translational failures of landfills during earthquake. The factor of safety gradually increases with the increase of the height of retaining wall for various horizontal seismic coefficients. A higher retaining wall is beneficial to the seismic stability of the landfill. Simply ignoring the retaining wall will lead to serious underestimation of the factor of safety. Besides, the approximate solution of the yield acceleration coefficient of the landfill is also presented based on the calculated method. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. Role of quaternary additions on dislocated martensite, retain austenite and mechanical properties of Fe/Cr/C structural steels

    International Nuclear Information System (INIS)

    Rao, B.V.N.

    1978-02-01

    The influence of quaternary alloy additions of Mn and Ni to Fe/Cr/C steels which have been designed to provide superior mechanical properties has been investigated. Transmission electron microscopy and x-ray analysis revealed increasing amounts of retained austenite with Mn up to 2 w/o and with 5 w/o Ni additions after quenching from 1100 0 C. This is accompanied by a corresponding improvement in toughness properties of the quaternary alloys. In addition, the generally attractive combinations of strength and toughness in these quaternary alloys is attributed to the production of dislocated lath martensite from a homogeneous austenite phase free from undissolved alloy carbides. Grain-refining resulted in a further increase in the amount of retained austenite

  6. Tooth Retained Implant: No More an Oxymoron

    Directory of Open Access Journals (Sweden)

    Divya Bhat

    2011-03-01

    Full Text Available Introduction: Periodontally af-fected teeth are treated in one of the two ways. (1 Tooth retention after periodontal surgery, in which the degree of regeneration achieved is unpredictable. (2 Tooth extrac-tion and implant placement. Implants have an osseointegrated surface which does not provide adequate shock absorption. Regeneration can be achieved by resecting the crown of the affected tooth and submerging the root. This technique has not had a clinical application so far as the tooth becomes difficult to restore. Placing an implant within the root can make the retained root restorable. At the same time, as the implant is placed within the root surface it achieves a periodontal integration which dampens occlusal forces better than osseointegration. Therefore, such a “tooth retained implant” may serve as an additional treatment option with significant benefits over tooth retention and implant placement alone. The hypothesis: Implants placed within retained roots have shown cementum deposition and attachment of periodontal ligament fibers over their surface. This periodontal attachment may be able to dam-pen forces better than in an osseointegrated implant. Moreover, since an implant is being placed, the crown of the tooth can be resected and submerged. This prevents epithelial migration, allows for the periodontal ligament cells to populate the wound and favors regeneration.Evaluation of the hypothesis: The technique of placing implants within cavities prepared in the root and then submerging them are simple for any practitioner placing implants routinely.

  7. Factors influencing success of cement versus screw-retained implant restorations: a clinical review

    Directory of Open Access Journals (Sweden)

    Ahmad Manawar

    2012-10-01

    Full Text Available Aim: As more and more dental practitioners are focusing on implant-supported fixed restorations, some clinicians favor the use of cement retained restorations while others consider screw retained prosthesis to be the best choice. Discussion: In screw-retained restorations, the fastening screw provides a solid joint between the restoration and the implant abutment, while in cement-retained prostheses the restorative screw is eliminated to enhance esthetics, occlusal stability, and passive fit of the restorations. The factors that influence the type of fixation of the prostheses to the implants like passivity of the framework, ease of fabrication, occlusion, esthetics, accessibility, retention and retrievability are discussed in this article with scientific studies demonstrating superior outcomes of one technique over another. Screwretained implant restorations have an advantage of predictable retention, retrievability and lack of potentially retained subgingival cement. However, a few disadvantages exist such as precise placement of the implant for optimal and esthetic location of the screw access hole and obtaining passive fit. On the other hand, cement retained restorations eliminate unesthetic screw access holes, have passive fit of castings, reduced complexity of clinical and lab procedures, enhanced esthetics, reduced cost factors and non disrupted morphology of the occlusal table. Conclusion: This article compares the advantages, potential disadvantages and limitations of screw and cement retained restorations and their specific implications in the most common clinical situation.

  8. Systemic Presentation of Retained Foreign Body in the Peritoneal Cavity (Gossypiboma

    Directory of Open Access Journals (Sweden)

    S Mehrabi

    2010-04-01

    Full Text Available Introduction & Objective: One of the infrequent complications of surgical operations is retained foreign body in body cavities which lead to morbidity and mortality for patients and also medico-legal problems for surgeons. Gossypiboma is an uncommon surgical complication, which is defined as a mass or cystic lesion due to retained surgical sponge in the abdominal cavity. Retained foreign body causes abscess, fistula, mass, obstruction after surgical operations and is diagnosed by x ray evaluation. In all patients, it is presented with pain, palpable mass. The infected post operation retained foreign bodies should be considered in differential diagnosis. In this study, we reported a patient with systemic presentation of retained two foreign bodies (surgical sponge in abdominal cavity. Case: The patient is a 32 years old female, which after cesarean section in 2008 developed abdominal pain, anorexia, and weight loss. The patient was referred to a specialist, and para-clinical checkup was done on her. In sonography and CT-scan, two cystic lesions with calcified wall were reported in the left and right sides of the abdomen. Then, the patient was referred to a surgeon with the diagnosis of hydatid cyst. During operation, cystic lesion with adhesion to viscera in the right side of the abdomen and a mass lesion in the descending colon in the left side were seen.The pathology report showed a surgical sponge in the right cystic lesion and surgical towel in the descending colon. Conclusion: Retained foreign bodies should be considered in differential diagnosis of any post operative patients who are presented with pain, infection, or palpable mass.

  9. Mesoporous silica nanotubes hybrid membranes for functional nanofiltration

    International Nuclear Information System (INIS)

    El-Safty, Sherif A; Shahat, Ahmed; Mekawy, Moataz; Nguyen, Hoa; Warkocki, Wojciech; Ohnuma, Masato

    2010-01-01

    The development of nanofiltration systems would greatly assist in the production of well-defined particles and biomolecules with unique properties. We report a direct, simple synthesis of hexagonal silica nanotubes (NTs), which vertically aligned inside anodic alumina membranes (AAM) by means of a direct templating method of microemulsion phases with cationic surfactants. The direct approach was used as soft templates for predicting ordered assemblies of surfactant/silica composites through strong interactions within AAM pockets. Thus, densely packed NTs were successfully formed in the entirety of the AAM channels. These silica NTs were coated with layers of organic moieties to create a powerful technique for the ultrafine filtration. The resulting modified-silica NTs were chemically robust and showed affinity toward the transport of small molecular particles. The rigid silica NTs inside AAM channels had a pore diameter of ≤ 4 nm and were used as ultrafine filtration systems for noble metal nanoparticles (NM NPs) and semiconductor nanocrystals (SC NCs) fabricated with a wide range of sizes (1.0-50 nm) and spherical/pyramidal morphologies. Moreover, the silica NTs hybrid membranes were also found to be suitable for separation of biomolecules such as cytochrome c (CytC). Importantly, this nanofilter design retains high nanofiltration efficiency of NM NPs, SC NCs and biomolecules after a number of reuse cycles. Such retention is crucial in industrial applications.

  10. New developments in ultrasonic inspection of retaining rings on generators in operation

    International Nuclear Information System (INIS)

    Koch-Mathian, A.

    1990-01-01

    The ultrasonic inspection of retaining rings of operating generators has been operational since 1986. The aim of this presentation is to outline the experience acquired on many retaining rings on different types of generators. In-situ inspections have made it possible to detect more exactly the different shape echoes for the various elements located beneath the retaining ring such as rotor teeth, damping and epoxy insulation. Various methods of identifying these parts are currently being developed. Investigation on corroded retaining rings has made it possible to demonstrate the close correlation between the transverse beam detection and the presence of actual cracks identified by micrograph. The specific facies of these cracks precludes the use of classic dimensioning techniques, but a method based on longitudinal wave detection has already given encouraging results

  11. Selection of a Vegetable Water-Retaining Material and Its Effects on the Growth and Quality of Cucumber under Drought Stress Part 1 : Selection of a Vegetable Water-Retaining Material

    OpenAIRE

    Yang, Shang-Dong; Wang, Rui; Li, Gang; Egashira, Kazuhiko

    2008-01-01

    Water-retention capacities of moss, common water hyacinth and Late Juncellus were compared with that of SAP (super absorbent polymers), a presently used chemical water-retaining material. Moss was highest in the amount of water retained per unit weight among the three vegetable materials and showed a somewhat higher water-retention capacity than did SAP. However, it is difficult to collect moss enough for use as a water-retaining material, and collection of a large amount of moss easily lea...

  12. Retainment of r-process material in dwarf galaxies

    Science.gov (United States)

    Beniamini, Paz; Dvorkin, Irina; Silk, Joe

    2018-04-01

    The synthesis of r-process elements is known to involve extremely energetic explosions. At the same time, recent observations find significant r-process enrichment even in extremely small ultra-faint dwarf (UFD) galaxies. This raises the question of retainment of those elements within their hosts. We estimate the retainment fraction and find that it is large ˜0.9, unless the r-process event is very energetic (≳ 1052erg) and / or the host has lost a large fraction of its gas prior to the event. We estimate the r-process mass per event and rate as implied by abundances in UFDs, taking into account imperfect retainment and different models of UFD evolution. The results are consistent with previous estimates (Beniamini et al. 2016b) and with the constraints from the recently detected macronova accompanying a neutron star merger (GW170817). We also estimate the distribution of abundances predicted by these models. We find that ˜0.07 of UFDs should have r-process enrichment. The results are consistent with both the mean values and the fluctuations of [Eu/Fe] in galactic metal poor stars, supporting the possibility that UFDs are the main 'building blocks' of the galactic halo population.

  13. A survey of failed post-retained restorations

    DEFF Research Database (Denmark)

    Peutzfeldt, A; Sahafi, A; Asmussen, E

    2008-01-01

    Survival of endodontically treated, post-restored teeth depends on a multitude of factors, all of which are practically impossible to include in a randomized, controlled clinical study. The purpose of this survey was to characterize and analyze reported failures of post-retained restorations...

  14. An appraisal of retained placentae in Ibadan: a five year review ...

    African Journals Online (AJOL)

    During the study period, 4980 deliveries took place at the University College Hospital, Ibadan and 106 cases of retained placenta were managed making the incidence 2.13 per cent of all births. Results: During the five year period, there were 106 patients with retained placenta; of these, 90 (84.9%) case notes were ...

  15. Model Tests on the Retaining Walls Constructed from Geobags Filled with Construction Waste

    OpenAIRE

    Wen, Hua; Wu, Jiu-jiang; Zou, Jiao-li; Luo, Xin; Zhang, Min; Gu, Chengzhuang

    2016-01-01

    Geobag retaining wall using construction waste is a new flexible supporting structure, and the usage of construction waste to fill geobags can facilitate the construction recycling. In this paper, model tests were performed on geobag retaining wall using construction waste. The investigation was concentrated on the slope top settlement, the distribution characteristics of the earth pressures on retaining walls and horizontal wall displacements, and slope failure modes. The results indicated t...

  16. The effects of retained austenite on dry sliding wear behavior of carburized steels

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung-Jun [Research Inst. of Industrial Science and Technology, Steel Products Dept., Pohang (Korea, Republic of); Kweon, Young-Gak [Research Inst. of Industrial Science and Technology, Steel Products Dept., Pohang (Korea, Republic of)

    1996-04-01

    Ring-on-square tests on two kinds of low-alloy carburized steel which were AISI 8620 and 4140 were carried out to study the dry sliding wear behavior. The influence of different retained austenite level of 6% to 40% was evaluated while trying to eliminate other factors. Test results show that the effects of grain size and carburized steel species are negligible in dry sliding wear behavior. While the influence of retained austenite is negligible at 20 kg load condition, wear resistance is decreased at 40 kg load condition as the retained austenite level is increased from 6% to 30%. However, wear resistance is again increased above about 30% of retained austenite level at 40 kg load condition. (orig.)

  17. A Long Gravity-Piston Corer Developed for Seafloor Gas Hydrate Coring Utilizing an In Situ Pressure-Retained Method

    Directory of Open Access Journals (Sweden)

    Lin-Yi Gu

    2013-07-01

    Full Text Available A corer, which can obtain long in situ pressure-retained sediments of up to 30 m core containing gas hydrates, has been applied in the South China Sea (SCS dozens of times. The corer presented in this paper is a convenient, efficient and economical long in situ pressure-retained coring and research tool for submarine sediments, that can applied to completely cope with all sediments close to the seafloor ranging from shallow waters to the deep sea depths of 6000 m. This article mainly presents the overall structure, working principles, key pressure-retained components, coring mechanism, sea trials and outlook of the corer. The analyses found that the coring ability was affected by formation characteristics, the outer diameter of the core barrels and inner diameter of the core liners, the shapes of the cutter and the dead weight of the corer. This study can provide the practical basis for the structural optimization of this type of corer and designs for corers with greater penetrability. Sea trials showed that the developed corer presented in this paper can support the in situ pressure of the seafloor sediment core, which is an improvement over the conventional piston corer.

  18. Magnet retained cheek plumper in complete denture esthetics: a case report.

    Directory of Open Access Journals (Sweden)

    Suryakant Chhagan Deogade

    2014-02-01

    Full Text Available This clinical report describes a technique to improve support for sunken cheeks using magnet retained detachable acrylic cheek plumpers. The new generation of magnets with improved technology provides sufficient denture retention for clinical application. However, further follow-up may be necessary to ascertain the long-term usefulness of the magnet-retained prosthesis, because of corrosion and further loss of magnetism.

  19. Retaining professional nurses in South Africa: Nurse managers ...

    African Journals Online (AJOL)

    Retaining professional nurses in South Africa: Nurse managers' perspectives. ... This implies that creating a favourable environment in the workplace situation ... Unsafe working environments and a lack of resources threaten the safety and ...

  20. Early Decomposition of Retained Heavy Silicone Oil Droplets

    Directory of Open Access Journals (Sweden)

    Touka Banaee

    2012-01-01

    Full Text Available Purpose: To report a case of early decomposition of retained heavy silicone oil droplets. Case Report: The single highly myopic eye of a 16-year-old boy with history of scleral buckling and buckle revision developed redetachment due to inferior retinal dialysis. The patient underwent pars plana vitrectomy and injection of heavy silicone oil. Early emulsification of the silicone oil was observed following surgery, which was removed 4 weeks later in another operation. Retained heavy silicone droplets lost their heavier- than-water specific gravity within 2 months together with extensive iris depigmentation, and release of pigment granules into the anterior chamber and vitreous cavity. Conclusion: This case report demonstrates that heavy silicone oil droplets can undergo in vivo chemical decomposition with possible toxic effects on ocular tissues.

  1. The cyclops lesion after bicruciate-retaining total knee replacement

    Directory of Open Access Journals (Sweden)

    Mark A. Klaassen, MD, FACS

    2017-12-01

    Full Text Available The cyclops lesion is a localized anterior arthrofibrosis most commonly seen following anterior cruciate ligament reconstruction. The lesion forms at the anterior cruciate ligament insertion creating a painful extension block between femoral intercondylar notch and tibial plateau. We present 2 cases (3 knees in which cyclops lesions appeared atypically following bicruciate-retaining total knee replacement. Two lesions occurred in a single patient following bilateral knee replacement. One lesion occurred in an active sportswoman. All 3 resolved following arthroscopic debridement. We describe the presentation of this unusual complication and suggest keys to its diagnosis, treatment, and prevention. Keywords: Cyclops lesion, Bicruciate-retaining, Total knee arthroplasty, Extension deficit

  2. Health matters in hiring and retaining personnel

    NARCIS (Netherlands)

    Houtman, I.L.D.

    2014-01-01

    Health is the most important issue when an employer is deciding whether to hire a worker, according to a new study from the Netherlands. The research looked at the results of a ‘vignette’ study on employer preferences when hiring or retaining personnel. It also showed that when an employer is

  3. Failure evolution in granular material retained by rigid wall in active mode

    Science.gov (United States)

    Pietrzak, Magdalena; Leśniewska, Danuta

    2012-10-01

    This paper presents a detailed study of a selected small scale model test, performed on a sample of surrogate granular material, retained by a rigid wall (typical geotechnical problem of earth thrust on a retaining wall). The experimental data presented in this paper show that the deformation of granular sample behind retaining wall can undergo some cyclic changes. The nature of these cycles is not clear - it is probably related to some micromechanical features of granular materials, which are recently extensively studied in many research centers in the world. Employing very precise DIC (PIV) method can help to relate micro and macro-scale behavior of granular materials.

  4. Prediction of retained residual stresses in laboratory fracture mechanics specimens extracted from welded components

    International Nuclear Information System (INIS)

    Hurlston, R.G.; Sherry, A.H.; James, P.; Sharples, J.K.

    2015-01-01

    The measurement of weld material fracture toughness properties is important for the structural integrity assessment of engineering components. However, welds can contain high levels of residual stress and these can be retained in fracture mechanics specimens, particularly when machined from non-stress relieved welds. Retained residual stresses can make the measurement of valid fracture toughness properties difficult. This paper describes the results of analytical work undertaken to investigate factors that can influence the magnitude and distribution of residual stresses retained in fracture mechanics specimen blanks extracted from as-welded ferritic and austenitic stainless steel plates. The results indicate that significant levels of residual stress can be retained in specimen blanks prior to notching, and that the magnitude and distribution of stress is dependent upon material properties, specimen geometry and size, and extraction location through the thickness of the weld. Finite element modelling is shown to provide a useful approach for estimating the level and distributions of retained residual stresses. A new stress partitioning approach has been developed to estimate retained stress levels and results compare favourably with FE analysis and available experimental data. The approach can help guide the selection of specimen geometry and machining strategies to minimise the level of residual stresses retained in fracture mechanics specimen blanks extracted from non stress-relieved welds and thus improve the measurement of weld fracture toughness properties. - Highlights: • A simplified method for generating realistic weld residual stresses has been developed. • It has been shown that significant levels of residual stress can be retained within laboratory fracture mechanics specimens. • The level and distribution is dependant upon material, specimen type, specimen size and extraction location. • A method has been developed to allow estimates of the

  5. [Application of single-retainer all-ceramic resin-bonded fixed partial denture in replacing single anterior tooth].

    Science.gov (United States)

    Lili, Yang; Debiao, Du; Ruoyu, Ning; Deying, Chen; Junling, Wu

    2017-08-01

    Objective In this study, we aimed to evaluate the clinical effect of single-retainer all-ceramic resin-bonded fixed partial denture (RBFPD) on the single anterior tooth loss patients. Methods A total of 20 single-retainer all-ceramic RBFPD
were fabricated and evaluated in a two-year follow-up observation. The restorations were examined on the basis of the American Public Health Association (APHA) criteria. Results A total of 20 single-retainer all-ceramic RBFPD achieved class A evaluation after a six-month follow-up observation. One single-retainer all-ceramic RBFPD was classified as class B for secondary caries after a one-year follow-up observation. After a two-year follow-up observation, one single-retainer all-ceramic RBFPD was classified as class B because of secondary caries, and one single-retainer all-ceramic RBFPD was classified as class B because of fracture. Conclusion Single-retainer all-ceramic RBFPD is a promising and optional method in replacing single anterior tooth.

  6. 15 CFR 762.2 - Records to be retained.

    Science.gov (United States)

    2010-01-01

    ..., Statement by Ultimate Consignee and Purchaser; (17) § 748.13, Delivery Verification (DV); (18) § 748.2(c... to be retained; (38) § 764.2, Violations; (39) § 764.5, Voluntary self-disclosure; and (40) § 766.10...

  7. Implementation of a protocol to reduce occurrence of retained sponges after vaginal delivery.

    Science.gov (United States)

    Lutgendorf, Monica A; Schindler, Lynnett L; Hill, James B; Magann, Everett F; O'Boyle, John D

    2011-06-01

    Retained sponges (gossypiboma) following vaginal delivery are an uncommon occurrence. Although significant morbidity from such an event is unlikely, there are many reported adverse effects, including symptoms of malodorous discharge, loss of confidence in providers and the medical system, and legal claims. To report a protocol intended to reduce the occurrence of retained sponges following vaginal delivery. After identification of limitations with existing delivery room protocols, we developed a sponge count protocol to reduce occurrence of retained vaginal sponges. We report our experience at Naval Medical Center Portsmouth, a large tertiary care military treatment facility with our efforts to implement a sponge count protocol to reduce retained sponges following vaginal delivery. With appropriate pre-implementation training, protocols which incorporate post-delivery vaginal sweep and sponge counts are well accepted by the health care team and can be incorporated into the delivery room routine.

  8. Effect of Abutment Modification and Cement Type on Retention of Cement-Retained Implant Supported Crowns

    Science.gov (United States)

    Farzin, Mitra; Torabi, Kianoosh; Ahangari, Ahmad Hasan; Derafshi, Reza

    2014-01-01

    Objective: Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations. Materials and Method: Two prefabricated abutments were attached to their corresponding analogs and embedded in an acrylic resin block. The first abutment (control group) was left intact without any modifications. The screw access channel for the first abutment was completely filled with composite resin. In the second abutment, (test group) the axial wall was partially removed to form an abutment with 3 walls. Wax models were made by CAD/CAM. Ten cast copings were fabricated for each abutment. The prepared copings were cemented on the abutments by Temp Bond luting agent under standardized conditions (n=20). The assemblies were stored in 100% humidity for one day at 37°C prior to testing. The cast crown was removed from the abutment using an Instron machine, and the peak removal force was recorded. Coping/abutment specimens were cleaned after testing, and the testing procedure was repeated for Dycal luting agent (n=20). Data were analyzed with two- way ANOVA (α=0.05). Results: There was no significant difference in the mean transformed retention (Ln-R) between intact abutments (4.90±0.37) and the abutments with 3 walls (4.83±0.25) using Dycal luting agent. However, in TempBond group, the mean transformed retention (Ln-R) was significantly lower in the intact abutment (3.9±0.23) compared to the abutment with 3 walls (4.13±0.33, P=0.027). Conclusion: The retention of cement-retained implant restoration can be improved by the type of temporary cement used. The retention of cast crowns cemented to implant abutments with TempBond is influenced by the wall removal. PMID:25628660

  9. Effect of abutment modification and cement type on retention of cement-retained implant supported crowns.

    Directory of Open Access Journals (Sweden)

    Mitra Farzin

    2014-06-01

    Full Text Available Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations.Two prefabricated abutments were attached to their corresponding analogs and embedded in an acrylic resin block. The first abutment (control group was left intact without any modifications. The screw access channel for the first abutment was completely filled with composite resin. In the second abutment, (test group the axial wall was partially removed to form an abutment with 3 walls. Wax models were made by CAD/CAM. Ten cast copings were fabricated for each abutment. The prepared copings were cemented on the abutments by Temp Bond luting agent under standardized conditions (n=20. The assemblies were stored in 100% humidity for one day at 37°C prior to testing. The cast crown was removed from the abutment using an Instron machine, and the peak removal force was recorded. Coping/abutment specimens were cleaned after testing, and the testing procedure was repeated for Dycal luting agent (n=20. Data were analyzed with two- way ANOVA (α=0.05.There was no significant difference in the mean transformed retention (Ln-R between intact abutments (4.90±0.37 and the abutments with 3 walls (4.83±0.25 using Dycal luting agent. However, in TempBond group, the mean transformed retention (Ln-R was significantly lower in the intact abutment (3.9±0.23 compared to the abutment with 3 walls (4.13±0.33, P=0.027.The retention of cement-retained implant restoration can be improved by the type of temporary cement used. The retention of cast crowns cemented to implant abutments with TempBond is influenced by the wall removal.

  10. Chronic Actinomyces Infection Caused by Retained Cervical Cerclage: A Case Report.

    Science.gov (United States)

    Lyttle, Brianna; Johnson, Julia V

    2016-01-01

    Historically, Actinomyces infection has been associated primarily with the intrauterine device. Recently, case reports associating Actinomyces with other implants have been described, including nonwoven polypropylene mesh used for urethral slings and Mersilene cerclage placements. However, there are no reported cases of chronic Actinomyces infections associated with retained Mersilene cerclage. A 51-year-old woman, gravida 3, para 3, presented with a 10-year history of vaginal discharge and Actinomyces identified on endometrial biopsy. After failing medical treatment and undergoing a hysterectomy, the patient was found to have a retained Mersilene cerclage. This is the first case to report persistent Actinomyces infection with a retained Mersilene cerclage. No current recommendations exist for assessing full removal of cerclage. Clinicians should have a high suspicion of Actinomyces infection in a patient who presents with persistent vaginal discharge and history of cerclage placement.

  11. Assessing the MR compatibility of dental retainer wires at 7 Tesla.

    Science.gov (United States)

    Wezel, Joep; Kooij, Bert Jan; Webb, Andrew G

    2014-10-01

    To determine the MR compatibility of common dental retainer wires at 7 Tesla in terms of potential RF heating and magnetic susceptibility effects. Electromagnetic simulations and experimental results were compared for dental retainer wires placed in tissue-mimicking phantoms. Simulations were then performed for a human model with wire in place. Finally, image quality was assessed for different scanning protocols and wires. Simulations and experimental data in phantoms agreed well, with the length of the wire correlating to maximum heating in phantoms being approximately 47 mm. Even in this case, no substantial heating occurs when scanning within the specific absorption rate (SAR) guidelines for the head. Image distortions from the most ferromagnetic dental wire were not significant for any brain region. Dental retainer wires appear to be MR compatible at 7 Tesla. Copyright © 2013 Wiley Periodicals, Inc.

  12. Rehabilitation of maxillary arch with attachment-retained mesh-reinforced single complete denture

    Science.gov (United States)

    Vamsi Krishna, C H; Rao, A Kaleshwar; Sekhar, N Chandra; Shastry, Y Mahadev

    2014-01-01

    Fabrication of conventional complete dentures was one of the most commonly advised treatment options to mange edentulous patients since many years. One of the commonly encountered challenging tasks in prosthodontics is a clinical situation in which patients have maxillary completely edentulous arches opposing mandibular natural dentition. This situation can be effectively managed by retaining some of the natural teeth as overdenture abutments. Tooth supported overdenture retained by attachments will improve retention, support and stability, and reduces rate of ridge resorption along with psychological benefits to the patients by providing tactile sensation. The present case report describes management of patients with edentulous maxillary arch opposing natural mandibular dentition-rehabilitated attachment-retained mesh-reinforced overdenture. PMID:24574522

  13. Rehabilitation of maxillary arch with attachment-retained mesh-reinforced single complete denture.

    Science.gov (United States)

    Vamsi Krishna, C H; Rao, A Kaleshwar; Sekhar, N Chandra; Shastry, Y Mahadev

    2014-02-26

    Fabrication of conventional complete dentures was one of the most commonly advised treatment options to mange edentulous patients since many years. One of the commonly encountered challenging tasks in prosthodontics is a clinical situation in which patients have maxillary completely edentulous arches opposing mandibular natural dentition. This situation can be effectively managed by retaining some of the natural teeth as overdenture abutments. Tooth supported overdenture retained by attachments will improve retention, support and stability, and reduces rate of ridge resorption along with psychological benefits to the patients by providing tactile sensation. The present case report describes management of patients with edentulous maxillary arch opposing natural mandibular dentition-rehabilitated attachment-retained mesh-reinforced overdenture.

  14. Quasi-experimental designs in practice-based research settings: design and implementation considerations.

    Science.gov (United States)

    Handley, Margaret A; Schillinger, Dean; Shiboski, Stephen

    2011-01-01

    Although randomized controlled trials are often a gold standard for determining intervention effects, in the area of practice-based research (PBR), there are many situations in which individual randomization is not possible. Alternative approaches to evaluating interventions have received increased attention, particularly those that can retain elements of randomization such that they can be considered "controlled" trials. Methodological design elements and practical implementation considerations for two quasi-experimental design approaches that have considerable promise in PBR settings--the stepped-wedge design, and a variant of this design, a wait-list cross-over design, are presented along with a case study from a recent PBR intervention for patients with diabetes. PBR-relevant design features include: creation of a cohort over time that collects control data but allows all participants (clusters or patients) to receive the intervention; staggered introduction of clusters; multiple data collection points; and one-way cross-over into the intervention arm. Practical considerations include: randomization versus stratification, training run in phases; and extended time period for overall study completion. Several design features of practice based research studies can be adapted to local circumstances yet retain elements to improve methodological rigor. Studies that utilize these methods, such as the stepped-wedge design and the wait-list cross-over design, can increase the evidence base for controlled studies conducted within the complex environment of PBR.

  15. Odynophagia following retained bee stinger

    Directory of Open Access Journals (Sweden)

    S Viswanathan

    2012-01-01

    Full Text Available Nearly half of Hymenoptera stings affect the head and neck region of victims, but reports on oropharyngeal bee stings are very few. We describe the case of a patient with odynophagia and suffocation in mass envenomation. He had a retained bee stinger whose removal was delayed for more than 24 hours following the sting, due to persisting angioedema. Odynophagia receded after removal of the stinger and treatment with paracetamol, steroids and metronidazole. The patient also developed rhabdomyolysis, renal failure and hepatitis that were treated with conservative therapy. Oropharyngeal stings can simulate symptoms of persisting angioedema in victims of mass envenomation.

  16. Oromaxillary Prosthetic Rehabilitation of a Maxillectomy Patient Using a Magnet Retained Two-Piece Hollow Bulb Definitive Obturator; A Clinical Report

    Science.gov (United States)

    Mohamed Usman, Jafar Abdulla; Ayappan, Anuroopa; Ganapathy, Dhanraj; Nasir, Nilofer Nisha

    2013-01-01

    Resection of a malignant lesion involving the maxilla produces severe oromaxillary defect that can seriously jeopardize the normal phonetics of the patient. These defects are effectively managed by well-designed and fabricated obturator. This paper discusses the oromaxillary prosthetic rehabilitation of a maxillectomy patient using a magnet retained two-piece hollow bulb definitive obturator. PMID:23533823

  17. Oromaxillary Prosthetic Rehabilitation of a Maxillectomy Patient Using a Magnet Retained Two-Piece Hollow Bulb Definitive Obturator; A Clinical Report

    Directory of Open Access Journals (Sweden)

    Jafar Abdulla Mohamed Usman

    2013-01-01

    Full Text Available Resection of a malignant lesion involving the maxilla produces severe oromaxillary defect that can seriously jeopardize the normal phonetics of the patient. These defects are effectively managed by well-designed and fabricated obturator. This paper discusses the oromaxillary prosthetic rehabilitation of a maxillectomy patient using a magnet retained two-piece hollow bulb definitive obturator.

  18. Effects of Geofoam Panels on Static Behavior of Cantilever Retaining Wall

    OpenAIRE

    Navid Hasanpouri Notash; Rouzbeh Dabiri

    2018-01-01

    Geofoam is one of the geosynthetic products that can be used in geotechnical applications. According to researches, expanded polystyrene (EPS) geofoam placed directly against a rigid retaining wall has been proposed as a strategy to reduce static loads on the wall. This study employed a finite difference analysis using a 2-D FLAC computer program by considering yielding and nonyielding states for retaining walls to explore the effectiveness of geofoam panels in improving the static performanc...

  19. Percutaneous Retrieval of a Retained Jackson-Pratt Drain Fragment

    International Nuclear Information System (INIS)

    Namyslowski, Jan; Halin, Neil J.; Greenfield, Alan J.

    1996-01-01

    A retained intraabdominal Jackson-Pratt drain fragment was percutaneously retrieved using an inflated angioplasty balloon that had been maneuvered inside of the drain lumen over a hydrophilic-coated steerable guidewire

  20. Illusory Speed is Retained in Memory during Invisible Motion

    Directory of Open Access Journals (Sweden)

    Luca Battaglini

    2013-05-01

    Full Text Available The brain can retain speed information in early visual short-term memory in an astonishingly precise manner. We investigated whether this (early visual memory system is active during the extrapolation of occluded motion and whether it reflects speed misperception due to contrast and size. Experiments 1A and 2A showed that reducing target contrast or increasing its size led to an illusory speed underestimation. Experiments 1B, 2B, and 3 showed that this illusory phenomenon is reflected in the memory of speed during occluded motion, independent of the range of visible speeds, of the length of the visible trajectory or the invisible trajectory, and of the type of task. These results suggest that illusory speed is retained in memory during invisible motion.

  1. Retained Gas Sampler Calibration and Simulant Tests

    Energy Technology Data Exchange (ETDEWEB)

    CRAWFORD, B.A.

    2000-01-05

    This test plan provides a method for calibration of the retained gas sampler (RGS) for ammonia gas analysis. Simulant solutions of ammonium hydroxide at known concentrations will be diluted with isotopically labeled 0.04 M ammonium hydroxide solution. Sea sand solids will also be mixed with ammonium hydroxide solution and diluent to determine the accuracy of the system for ammonia gas analysis.

  2. Retained Gas Sampler Calibration and Simulant Tests

    International Nuclear Information System (INIS)

    CRAWFORD, B.A.

    2000-01-01

    This test plan provides a method for calibration of the retained gas sampler (RGS) for ammonia gas analysis. Simulant solutions of ammonium hydroxide at known concentrations will be diluted with isotopically labeled 0.04 M ammonium hydroxide solution. Sea sand solids will also be mixed with ammonium hydroxide solution and diluent to determine the accuracy of the system for ammonia gas analysis

  3. Torque resistance of different stainless steel wires commonly used for fixed retainers in orthodontics.

    Science.gov (United States)

    Arnold, Dario T; Dalstra, Michel; Verna, Carlalberta

    2016-06-01

    Movements of teeth splinted by fixed retention wires after orthodontic treatment have been observed. The aetiological factors for these movements are unknown. The aim of this in vitro study was to compare the resistance to torque of different stainless steel wires commonly used for fixed retainers in orthodontics. Torquing moments acting on a retainer wire were measured in a mechanical force testing system by applying buccal crown torque to an upper lateral incisor in both a 3-teeth and in a 2-teeth setup. Seven stainless steel wires with different shape, type (plain, braided, coaxial, or chain) and dimensions were selected for this study. For a torquing angle of 16.2° in the 3-teeth setup torsion moments can vary between 390 cNmm and 3299 cNmm depending on the retainer wire. For the 2-teeth setup the torsion moments are much smaller. Exposure to the flame of a butane-gas torch for 10 seconds to anneal the wire reduces the stiffness of the retainer wire. Clinicians must select wires for fixed retainers very carefully since the difference in resistance to torque is large. A high level of torque control can be achieved with a plain 0.016 × 0.016-inch or a braided 0.016 × 0.022-inch stainless steel wire. A tooth attached by a retainer wire to only one neighbouring tooth is less resistant to torque than a tooth connected to two neighbouring teeth. Annealing a retainer wire with a flame reduces the stiffness of the wire markedly and can lead to a non-uniform and non-reproducible effect.

  4. Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview

    Directory of Open Access Journals (Sweden)

    Chui Ling Goo

    2017-01-01

    Full Text Available This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.

  5. Supra-aural gossypiboma: case report of a retained textile surgical sponge in an unusual location.

    Science.gov (United States)

    Chawla, N; Gupta, N; Dhawan, N

    2016-11-01

    Gossypiboma or retained surgical sponge is an infrequently encountered surgical complication, more so in the head and neck region. A literature search did not reveal a previously reported case of retained or concealed surgical sponge after microscopic ear surgery. We present a unique and previously unreported case of a 25-year-old male who presented with a cystic swelling in the right supra-aural region 5 months post-modified radical mastoidectomy of the right ear. Surgical excision of the swelling revealed a retained surgical sponge. We emphasise the importance of counting surgical sponges after every surgical step to minimise the incidence of such retained surgical items.

  6. CT and sonographic diagnosis of retained surgical sponge

    International Nuclear Information System (INIS)

    Matsumoto, Syunro; Aikawa, Hisayuki; Miyake, Hidetoshi; Mori, Hiromu; Maeda, Tohru; Nishimura, Hiro; Monzen, Yoshio; Ashizawa, Akira; Isomoto, Ichiro.

    1990-01-01

    Seven cases of pathologically proven retained surgical sponge were reviewed and classified into four types, depending on CT and US findings. CT showed a mass with tiny gas bubbles, and sonogram showed an echogenic area with strong posterior shadow (Type I). CT showed an irregular high density mass with no gas bubble, and sonogram showed an echogenic area with strong posterior shadow (Type II). CT showed a low density mass with irregular internal high density areas, and somogram showed a cystic mass with zigzag internal components (Type III). CT showed an eliptic high density mass with low density area internally. Judging from the experiment and operative findings, these patterns were decided by the number and status of the gauze, volume of the exudate and hematoma, and status of the granulation. The author concludes that these characteristic CT and US findings, together with a history of surgery, permit the correct diagnosis of retained surgical sponge. (author)

  7. Gossypiboma – the retained surgical swab: An enduring clinical ...

    African Journals Online (AJOL)

    Retained abdominal swabs remain a difficult problem. This review ... and continues to date, despite advances .... difficult problem to eradicate even though .... to complete multiple emergency surgeries with no rest is great, ... The position.

  8. The Analysis Stability of Anchor Retaining Wall

    International Nuclear Information System (INIS)

    Benamara, F. Z.; Belabed, L

    2011-01-01

    The construction of anchored retaining walls reach every day in the field of Civil Engineering especially in public works. Their dimensioning and stability are the axes of research for geotechnical. The rule is to reduce the active forces of the slide and increase the effective normal stress on the rupture surface. So that, we anchored tied-back (constituted by steel cables) in the stable ground located under the failure surface and we apply at the top a traction force. This effort can be distributed over the ground surface by means of small plates or massive reinforced concrete. The study of the stability of anchored retaining wall was also performed by using software GEO4. Many cases can be solved using analytical solutions available in the group GEO4 program, but for our standard model solution studied analytically proved unsatisfactory so we used a numerical analysis based on the method of finite element in this program. The results obtained by numerical study were interpreted to identify the precision numerical predictions. Moreover these methods were useful and economics in the realization of reinforced slopes by tied-buck. (author)

  9. Comparative evaluation of salivary bisphenol A levels in patients wearing vacuum-formed and Hawley retainers: An in-vivo study.

    Science.gov (United States)

    Raghavan, Akila Srinivasan; Pottipalli Sathyanarayana, Haritha; Kailasam, Vignesh; Padmanabhan, Sridevi

    2017-03-01

    The aims of the study were to evaluate and compare the bisphenol A (BPA) levels in saliva in patients using vacuum-formed retainers or Hawley retainers. Forty-five patients who had completed their fixed orthodontic treatment and were entering the retention phase were randomly allocated into 1 of 3 groups: vacuum-formed retainer, Hawley retainer fabricated by heat cure, and Hawley retainer fabricated by chemical cure. Saliva samples were collected immediately before placement, within 1 hour after placement, 1 week and 1 month after placement. Statistical analyses were performed by using 2-way analysis of variance and post-hoc multiple-comparisons Tukey HSD tests. Statistically significant BPA levels in saliva were found for all groups (P ≤0.05). The highest levels were noted in the vacuum-formed retainer group, followed by Hawley retainers fabricated by chemical cure; the lowest levels were found with Hawley retainers fabricated by heat cure. With many options available for removable retainers, clinicians should consider the BPA release from these retainers; a Hawley retainer fabricated by heat cure is a favorable choice. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  10. Properties of Shredded Roof Membrane–Sand Mixture and Its Application as Retaining Wall Backfill under Static and Earthquake Loads

    Directory of Open Access Journals (Sweden)

    Bennett Livingston

    2017-04-01

    Full Text Available About 20 billion square feet of Ethylene Propylene Diene Monomer (EPDM rubber is installed on roofs in the United States and most of them will be reaching the end of their lifespan soon. The purpose of this study is to investigate potential reuses of this rubber in Civil Engineering projects rather than disposing it into landfills. First, laboratory tests were performed on various shredded rubber-sand mixtures to quantify the basic geotechnical engineering properties. The laboratory test results show that the shredded rubber-sand mixture is lightweight with good drainage properties and has shear strength parameters comparable to sand. This indicates that the rubber-sand mixture has potential to be used for retaining wall backfill and many other projects. To assess the economic advantage of using shredded rubber-sand mixtures as a lightweight backfill for retaining walls subjected to static and earthquake loadings, geotechnical designs of a 6 m tall gravity cantilever retaining wall were performed. The computed volume of concrete to build the structural components and volume of backfill material were compared with those of conventional sand backfill. Results show significant reductions in the volume of concrete and backfill material in both static and earthquake loading conditions when the portion of shredded rubber increased in the mixture.

  11. Esthetic, functional, and prosthetic outcomes with implant-retained finger prostheses.

    Science.gov (United States)

    Aydin, Cemal; Nemli, Secil Karakoca; Yilmaz, Handan

    2013-04-01

    Traumatic amputation of fingers results in a serious impairment of hand function and affects the psychological status of the patients. The implant-retained finger prostheses are an alternative treatment. The aim of this case report is to represent the use of osseointegrated implants for retention of finger prostheses in a patient with amputated thumb and index finger. Dental implants were placed in the residual bone of the fingers using two-stage surgery. Custom-made attachments were used to provide retention between implants and silicone prostheses. Prosthetic fingernails were made of composite resin material. After 6 months, implants were clinically successful, and the patient was satisfied with the appearance and the function of the prostheses. The complications of broken prosthetic nail and mild discoloration were observed. Reconstruction of amputated fingers with implant-retained prosthesis is a worthwhile treatment providing esthetic, functional, and psychological benefits, although some complications might be experienced. Clinical relevance Implant-retained finger prostheses are an acceptable treatment modality for patients with amputated fingers. Evaluating implant prognosis, functional results and prosthetic results of the patients are necessary to address the benefits and complications of the treatment.

  12. INTRODUCTION The incidence of retained placenta varies greatly ...

    African Journals Online (AJOL)

    balance between the post-partum haemorrhage risk of leaving the placenta in ... Conclusion: Retained placenta still remains a potentially life threatening condition in ... obstetric services by high skilled health care providers in ensuring a properly conducted .... of the preterm placenta may require more uterine work and time ...

  13. 13 CFR 120.1707 - Seller's retained Loan Interest.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Seller's retained Loan Interest. 120.1707 Section 120.1707 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1707 Seller...

  14. Postoperative Radiculopathy Caused by a Retained Fractured Pedicle Cannulation Probe and Its Mechanism of Extraction.

    Science.gov (United States)

    Yuk, Frank; Steinberger, Jeremy; Skovrlj, Branko; Mascitelli, Justin; Cho, Samuel K; Caridi, John M

    2017-11-01

    Spine surgery relies heavily on technology and surgical instrumentation. Improperly used instrumentation can be detrimental to the patient. Despite multiple checkpoints to ensure that foreign bodies are not retained in surgery, numerous case reports have described retained foreign bodies; however, none of these cases involve retained instrumentation after open spine surgery. Of the retained objects, 4 were sponges and one was a Jamshidi needle fragment. Although smaller objects are more commonly the culprits, surgical instruments can break off, remain stuck, and cause clinical sequelae. This case presents a retained fractured pedicle finder as the cause of right L5 radiculopathy. To our knowledge, this report is the first to describe an instrumentation-associated postoperative radiculopathy. Because of the strength with which the object was impacted, its extraction proved difficult. The technique of removal using a mallet and osteotome in 4 directions to loosen its hold in the vertebral body. Attempts and eventual successful removal are described. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. [Capacity of extensive green roof to retain rainwater runoff in hot and humid region.

    Science.gov (United States)

    Liu, Ming Xin; Dai, Se Ping; Zhou, Tian Yang; Ruan, Lin; Zhang, Qiao Song

    2017-02-01

    The water logging has become the environmental problem of major cities with the sharp increase of impermeable urban pavement as the contributing cause. Abroad, the green roof has been widely used as a practical measure to intercept rainwater, yet the capacity of green roof to retain rainwater varies with climate conditions. As the hot and humid climate zone features high temperature, humidity and precipitation, it is meaningful to study the capacity of green roof to retain rainwater under such climatic condition. In this research, 3 plat forms were set up in Guangzhou in rainy and hot summer to test the capability of simple green roof to retain rainwater runoff, and the efficiency of green roof to retain rainwater under local climate conditions was worked out based on the meteorological observation and data measurement during the 13-month test period. The results showed that the simple green roof with a substrate thickness of 30, 50 and 70 mm could retain 27.2%, 30.9% and 32.1% of precipitation and reduce the average peak value by 18.9%, 26.2% and 27.7%, respectively. Given an urban built-up area of 1035.01 km 2 in Guangzhou and a roof area percentage of approximately 37.3% and assuming the green roofs with 30 mm-thick substrate were applied within the area, the light, medium and heavy rain could be delayed at 72.8%, 22.6% and 17.4%, respectively. Accordingly, the rainwater retained could reach up to 14317×10 4 m 3 . It suggested the great potential of the simple green roof in retaining rainwater. The research could serve as reference for the hot and humid climate zone to alleviate water logging and visualize sponge city construction.

  16. Fracture strength and bending of all-ceramic and fiber-reinforced composites in inlay-retained fixed partial dentures

    Directory of Open Access Journals (Sweden)

    Serkan Saridag

    2012-06-01

    Conclusions: Zirconia-based ceramic inlay-retained fixed partial dentures demonstrated the highest fracture strength. The fiber-reinforced composite inlay-retained fixed partial dentures demonstrated higher bending values than did the all-ceramic inlay-retained fixed partial dentures.

  17. Evaluation of the Effect of Axial Wall Modification and Coping Design on the Retention of Cement-retained Implant-supported Crowns

    Science.gov (United States)

    Derafshi, Reza; Ahangari, Ahmad Hasan; Torabi, Kianoosh; Farzin, Mitra

    2015-01-01

    Background and aims. Because of compromised angulations of implants, the abutments are sometimes prepared. The purpose of this study was to investigate the effect of removing one wall of the implant abutment on the retention of cement-retained crowns. Materials and methods. Four prefabricated abutments were attached to analogues and embedded in acrylic resin blocks. The first abutment was left intact. Axial walls were partially removed from the remaining abutments to produce abutments with three walls. The screw access channel for the first and second abutments were completely filled with composite resin. For the third and fourth abutments, only partial filling was done. Wax-up models were made by CAD/CAM. Ten cast copings were fabricated for each abutment. The copings of fourth abutment had an extension into the screw access channel. Copings were cemented with Temp Bond. The castings were removed from the abutment using an Instron machine, and the peak removal force was recorded. A one-way ANOVA was used to test for a significant difference followed by the pairwise comparisons. Results. The abutments with opened screw access channel had a significantly higher retention than the two other abutments. The abutment with removed wall and no engagement into the hole by the castings exhibited the highest retention. Conclusion. Preserving the opening of screw access channel significantly increases the retention where one of the axial walls of implant abutments for cement-retained restorations is removed during preparation. PMID:25973152

  18. The stability of retained austenite at different locations during straining of I&Q&P steel

    Energy Technology Data Exchange (ETDEWEB)

    Song, Chenghao [School of Materials Science and Engineering, University of Science & Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing 100083 (China); Yu, Hao, E-mail: yuhao@ustb.edu.cn [School of Materials Science and Engineering, University of Science & Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing 100083 (China); Li, Lili; Zhou, Tao; Lu, Jun [School of Materials Science and Engineering, University of Science & Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing 100083 (China); Liu, Xihui [Qingzhou Construction Quality and Safety Supervision Station, Shandong 262500 (China)

    2016-07-18

    This paper presents a detailed investigation of the transformation behavior of retained austenite at different locations of intercritical heating, quenching and partitioning (I&Q&P) steel. The consumption of retained austenite at different strains is investigated by X-ray diffraction (XRD). Results indicate that retained austenite can transform into martensite progressively during the whole deformation process, which is in favor of a good combination of strength and ductility, contributing to a high product of strength and elongation (PSE) of 31.9 GPa%. The transformation characteristics of retained austenite at different locations after different strains are characterized by electron back scattered diffraction (EBSD) and transmission electron microscopy (TEM). Results show that the transformation preferentially occurs in the retained austenite at ferrite grain boundaries, subsequently the one within ferrite grains (at 10% strain) and eventually the one between martensite laths (at 15% strain). In FCC phase, the average local misorientations are 0.547° and 0.674° at 5% and 10% strain, respectively; however, the values are not more than 0.7° at 15% and 20% strain due to the TRIP effect. For the retained austenite within ferrite grains, the interior part preferentially transforms into twin martensite, while the interface still remains due to alloying elements segregation.

  19. Effect of tightening torque on the marginal adaptation of cement-retained implant-supported fixed dental prostheses.

    Science.gov (United States)

    Ghanbarzadeh, Jalil; Dashti, Hossin; Karamad, Reza; Alikhasi, Marzieh; Nakhaei, Mohammadreza

    2015-01-01

    The final position of the abutment changes with the amount of tightening torque. This could eventually lead to loss of passivity and marginal misfit of prostheses. The aim of this study was to evaluate the effect of three different tightening torques on the marginal adaptation of 3-unit cement-retained implant-supported fixed dental prostheses (FDPs). Two implants (Straumann) were inserted in an acrylic block so that one of the implants was placed vertically and the other at a 15° vertical angle. A straight abutment and a 15° angulated abutment were connected to the vertically and obliquely installed implants, respectively, so that the two abutments were parallel. Then, 10 cement-retained FDPs were waxed and cast. Abutments were tightened with 10, 20, and 35 Ncm torques, respectively. Following each tightening torque, FDPs were luted on respective abutments with temporary cement. The marginal adaptation of the retainers was evaluated using stereomicroscope. FDPs were then removed from the abutments and were sectioned at the connector sites. The retainers were luted again on their respective abutments. Luting procedures and marginal adaptation measurement were repeated. Data were analyzed by ANOVA and least significant difference tests (α = 0.05). After cutting the FDP connectors, the independent samples t-test was used to compare misfit values (α = 0.05). Following 10, 20, and 35 Ncm tightening torques, the marginal discrepancy of the retainers of FDPs significantly increased (P marginal discrepancies of these two retainers (P > 0.05). The marginal gap values of angulated abutment retainers (ANRs) were significantly higher than those of the straight abutment after cutting the connectors (P = 0.026). Within the limitations of this study, the marginal misfit of cement-retained FDPs increased continuously when the tightening torque increased. After cutting the connectors, the marginal misfit of the ANRs was higher than those of the straight abutment retainers.

  20. Retained placenta of dairy cows associated with managemental factors in Rajshahi, Bangladesh

    Directory of Open Access Journals (Sweden)

    K. M. Mozaffor Hossain

    2013-08-01

    Full Text Available Aim: The incidence of retained placenta of dairy cows in relation to individual animal level and farm management factors such as farm type, farm size, housing system, floor type, feed quality, time of parturition, farming experience of farmer and delivery pattern of cows was determined. Materials and Methods: A total 1205 parturated dairy cows conducted in nine upazilas and four Metro Thana of Rajshahi district during July 2010 to June 2011for attainment of the result. Individual animal and farm management factors associated with retained placenta were recorded in a structured questionnaire through face-to-face farmer's interview and reviewing farm records. The raw data were compiled and statistical SPSS program to analyze to obtained result. Results: The overall incidence of retained placenta was 13.4%. The incidence was significantly higher in Local × Sahiwal genotype (4.6% and late delivery (longer gestation period (80% than their counter groups (p<0.05. The large farm (6.0% had higher incidence and had no significant effect than medium and individual household. Similarly animals housed in Tin shed building with poor ventilation facilities (6.6%, animal housed in unscientific concrete floor (6.8%, animals mostly grassed along with small amount of straw supplied (5.4% and a farmer had less than one year farming experience (5.3% had not significant statistically show higher incidence of retained placenta. Conclusion: The local genotype; mini farm; supplied better feed quality; vast farming experience of farmer and normal delivery with eutocia had less chance of retained placenta of dairy cows. [Vet World 2013; 6(4.000: 180-184

  1. Textiloma, migration of retained long gauze from abdominal cavity to intestine

    Directory of Open Access Journals (Sweden)

    Hojjat Molaei Govarjin

    2010-01-01

    Full Text Available Retaining of long gauzes and surgical sponges in the abdomen is one of the most frequent medical errors usually manifests as abscess or abdomino- cutaneus fistulas and with no definite symptoms during lifetime. Here, we introduce a 35 year old woman with an intestino-cutaneal fistula caused by retained long gauze in the abdomen entered the terminal ileum,9 months after cesarean section. This is called “Textiloma”. There is no report of textiloma in Iran and there are only a few cases in the world.

  2. On the role of interlath retained austenite in the deformation of lath martensite

    International Nuclear Information System (INIS)

    Maresca, F; Kouznetsova, V G; Geers, M G D

    2014-01-01

    Literature presents extensive experimental evidence of large deformation and ductile fracture behaviour of lath martensite in martensitic and multi-phase high strength steels under quasi-static, uniaxial loading conditions. The physical origin of this apparent ductile behaviour of martensite is not clear, since martensite generally provides a high material strength. The presence of thin films of interlath retained austenite may trigger the observed apparent martensite ductility. The present contribution investigates the role played by interlath retained austenite on the mechanics of lath martensite by means of crystal plasticity simulations. It is shown that independently from the interlath retained austenite volume fraction and the exact lath morphology, localized shearing along the lath habit plane occurs as long as there are enough carriers for plasticity. The austenite film acts like a ‘greasy’ plane on which the stiffer laths can slide. The shearing mechanism is not a mere consequence of the lower flow stress in the austenitic phase, but it is largely due to the orientation relationship between the retained austenite face centred cubic lattice and the body centred cubic lath crystals. (paper)

  3. Retained Products of Conception: An Atypical Presentation Diagnosed Immediately with Bedside Emergency Ultrasound

    Directory of Open Access Journals (Sweden)

    Kristin Adkins

    2016-01-01

    Full Text Available Background. Retained products of conception is an important diagnosis to consider in patients presenting with postpartum complaints. Bedside ultrasound is a rapid, accurate, noninvasive modality to evaluate these patients. Objective. To report an atypical case of retained products of conception diagnosed with bedside ultrasound in the emergency department. Case Report. A 27-year-old female who was 1-month postpartum presented with vaginal bleeding, pelvic pain, and no fever. At the time of initial H&P, bedside ultrasound revealed echogenic material within the endometrial cavity with blood flow seen by color Doppler consistent with retained products of conception. The bedside ultrasound rapidly narrowed the differential and allowed a definitive diagnosis immediately. Ob/Gyn was consulted and dilation and curettage was performed in the operating room. Conclusions. Retained products of conception is an important diagnosis for the emergency physician to consider in at-risk patients. The sonographic findings are easily obtained and interpreted by emergency physicians. Earlier diagnosis of this disease process should lead to more focused patient evaluations and management.

  4. Composition and quantities of retained gas measured in Hanford waste tanks 241-AW-101 A-101, AN-105, AN-104, and AN-103

    International Nuclear Information System (INIS)

    Shekarriz, A.; Rector, D.R.; Mahoney, L.A.

    1997-03-01

    This report provides the results obtained for the first five tanks sampled with the Retained Gas Sampler (RGS): Tanks 241-AW-101, A-101, AN-105, AN-104, and AN-103. The RGS is a modified version of the core sampler used at Hanford. It is designed specifically, in concert with the gas extraction equipment in the hot cell, to capture and extrude a gas-containing waste sample in a hermetically sealed system. The retained gases are then extracted and stored in small gas canisters. The composition of the gases contained in the canisters was measured by mass spectroscopy. The total gas volume was obtained from analysis of the extraction process, as discussed in detail throughout this report. The following are the findings of this research: (1) The RGS is a viable approach for measuring retained gases in double- and single-shell waste tanks at Hanford. (2) Local measurements of void fraction with the RGS agree with the results obtained with the void fraction instrument (VFI) in most cases. (3) In the tanks sampled, more than 16% of the retained gas in the nonconvective layer was nitrogen (N 2 ). The fraction of nitrogen gas was approximately 60% in Tank 241-AW-101. This finding shows that not all the retained gas mixtures are flammable. (4) In the tanks sampled, the ratios of hydrogen to oxidizers were observed to be significantly higher than 1; i.e., these tanks are fuel-rich. Based on these observations, the RGS will be used to sample for retained gases in several single-shell tanks at Hanford. The remaining sections of this summary describe the RGS-findings for the first five tanks tested. The results are described in the order in which the tanks were sampled, to reflect the increasing experience on which RGS methods were based

  5. Large deformation and post-failure simulations of segmental retaining walls using mesh-free method (SPH)

    OpenAIRE

    Bui, H. H.; Kodikara, J. A.; Pathegama, R.; Bouazza, A.; Haque, A.

    2015-01-01

    Numerical methods are extremely useful in gaining insights into the behaviour of reinforced soil retaining walls. However, traditional numerical approaches such as limit equilibrium or finite element methods are unable to simulate large deformation and post-failure behaviour of soils and retaining wall blocks in the reinforced soil retaining walls system. To overcome this limitation, a novel numerical approach is developed aiming to predict accurately the large deformation and post-failure be...

  6. Myomectomy for Retained Placenta Due to Incarcerated Fibroid Mass

    African Journals Online (AJOL)

    and life threatening complication. We present a patient who had mid-trimester miscarriage, complicated by retained ... the couple gave consent for the termination of the pregnancy. .... In conclusion, it is pertinent to note that uterine fibroid in.

  7. An appraisal of retained placentae in ibadan: a five year review.

    Science.gov (United States)

    Obajimi, G O; Roberts, A O; Aimakhu, C O; Bello, F A; Olayemi, O

    2009-06-01

    To determine the frequency of retained placenta at the University College Hospital Ibadan (UCH). and to describe the socio-demographic characteristics of the patients and examine the risk factors predisposing to retained placenta. This is a descriptive study covering a period of 5 years from January 1(st) 2002 to December 31(st) 2006. During the study period, 4980 deliveries took place at the University College Hospital, Ibadan and 106 cases of retained placenta were managed making the incidence 2.13 per cent of all births. During the five year period, there were 106 patients with retained placenta; of these, 90 (84.9%) case notes were available for analysis. The mean age was 29.37 ± 4.99 years. First and second Para accounted for 52 per cent of the patients. Majority of the patient were unbooked for antenatal care in UCH with booked patients accounting for 27.8 per cent of the cases. The mean gestational age at delivery was 34.29 ± 6.02. Three patients presented to the hospital in shock of which 2 died on account of severe haemorrhagic shock. Fifty-eight patients (64.8%) presented with anaemia (packed cell volume less than 30 per cent) and 35 patients (38.8%) had blood transfusion ranging between 1-4 pints. 1 patient required hysterectomy on account of morbidly adherent placenta. Eleven patients (12.2%) had placenta retention in the past, 28 patients (31%) had a previous dilatation and curettage, 14 patients (15.5%) had previous caesarean sections and 47 patients (41.3%) had no known predisposing factors. Retained placenta still remains a potentially life threatening condition in the tropics due to the associated haemorrhage, and other complications related to its removal. The incidence and severity may be decreased by health education, women empowerment and the provision of facilities for essential obstetric services by high skilled health care providers in ensuring a properly conducted delivery with active management of the third stage of labour.

  8. CT findings of foreign body reaction to retained endoloop ligature plastic tube mimicking acute appendicitis: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Jae Hong; Kang, Chae Hoon; Choi, Soo Jung; Park, Man Soo; Jung, Seung Mun; Ryu, Dae Shick; Shin, Dong Rock [Dept. of Radiology, GangNeung Asan Hospital, University of Ulsan College of Medicine, Gangneung (Korea, Republic of)

    2016-07-15

    Many hospitals experience one or more retained surgical instrument events with risk of patient morbidity and medicolegal problems. Identification of retained surgical instrument is important. The radiologists should be familiar with imaging finding of retained surgical instrument. In a 62-year-old female with a retained plastic tube, localized peritoneal infiltration around air-containing tubular structure mimicked acute appendicitis on abdomen computed tomography (CT), one year after laparoscopic cholecystectomy. We reported CT findings of foreign body reaction related to retained Endoloop ligature plastic tube mimicking acute appendicitis.

  9. CT findings of foreign body reaction to retained endoloop ligature plastic tube mimicking acute appendicitis: A case report

    International Nuclear Information System (INIS)

    Ahn, Jae Hong; Kang, Chae Hoon; Choi, Soo Jung; Park, Man Soo; Jung, Seung Mun; Ryu, Dae Shick; Shin, Dong Rock

    2016-01-01

    Many hospitals experience one or more retained surgical instrument events with risk of patient morbidity and medicolegal problems. Identification of retained surgical instrument is important. The radiologists should be familiar with imaging finding of retained surgical instrument. In a 62-year-old female with a retained plastic tube, localized peritoneal infiltration around air-containing tubular structure mimicked acute appendicitis on abdomen computed tomography (CT), one year after laparoscopic cholecystectomy. We reported CT findings of foreign body reaction related to retained Endoloop ligature plastic tube mimicking acute appendicitis

  10. Determining the Number of Factors to Retain in EFA: Using the SPSS R-Menu v2.0 to Make More Judicious Estimations

    Directory of Open Access Journals (Sweden)

    Matthew Gordon Ray Courtney

    2013-04-01

    Full Text Available Exploratory factor analysis (EFA is a common technique utilized in the development of assessment instruments. The key question when performing this procedure is how to best estimate the number of factors to retain. This is especially important as under- or over-extraction may lead to erroneous conclusions. Although recent advancements have been made to answer the number of factors question, popular statistical packages do not come standard with these modern techniques. This paper details how to program IBM SPSS Statistics software (SPSS to conveniently perform five modern techniques designed to estimate the number of factors to retain. By utilizing the five empirically-supported techniques illustrated in this article, researchers will be able to more judiciously model data.

  11. Seismic performance of geosynthetic-soil retaining wall structures

    Science.gov (United States)

    Zarnani, Saman

    Vertical inclusions of expanded polystyrene (EPS) placed behind rigid retaining walls were investigated as geofoam seismic buffers to reduce earthquake-induced loads. A numerical model was developed using the program FLAC and the model validated against 1-g shaking table test results of EPS geofoam seismic buffer models. Two constitutive models for the component materials were examined: elastic-perfectly plastic with Mohr-Coulomb (M-C) failure criterion and non-linear hysteresis damping model with equivalent linear method (ELM) approach. It was judged that the M-C model was sufficiently accurate for practical purposes. The mechanical property of interest to attenuate dynamic loads using a seismic buffer was the buffer stiffness defined as K = E/t (E = buffer elastic modulus, t = buffer thickness). For the range of parameters investigated in this study, K ≤50 MN/m3 was observed to be the practical range for the optimal design of these systems. Parametric numerical analyses were performed to generate design charts that can be used for the preliminary design of these systems. A new high capacity shaking table facility was constructed at RMC that can be used to study the seismic performance of earth structures. Reduced-scale models of geosynthetic reinforced soil (GRS) walls were built on this shaking table and then subjected to simulated earthquake loading conditions. In some shaking table tests, combined use of EPS geofoam and horizontal geosynthetic reinforcement layers was investigated. Numerical models were developed using program FLAC together with ELM and M-C constitutive models. Physical and numerical results were compared against predicted values using analysis methods found in the journal literature and in current North American design guidelines. The comparison shows that current Mononobe-Okabe (M-O) based analysis methods could not consistently satisfactorily predict measured reinforcement connection load distributions at all elevations under both static

  12. animal trial on imaging appearances of abdominally retained gauze

    International Nuclear Information System (INIS)

    Wang Longxia; An Ningyu; Yin Hui; Wang Xiangdong; Li Jia; Bai Ying

    2000-01-01

    Objective: To evaluate the imaging appearances of abdominally retained crumpled gauze with US, CT and MRI and the changes with time. Methods: Eight rabbits were operated and crumpled gauze was put into in their abdominal cavity. US , plain and enhanced CT and MRI scan were performed on the day of operation, and 1 to 7 weeks after operation. The imaging appearances were compared with operation findings. Pathologic examination was done simultaneously. Results: Abdominally retained crumpled gauze was instantly adhesive with omentum and neighboring intestines tightly. Fibro-connective tissue membrane was produced at the adhesion site gradually, spreading out to enclose the crumpled gauze. The enclosure was finished completely in 3 to 4 weeks. Thickened membrane also invaded into the spaces within the gauze. The crumpled gauze was eventually infected. These changes could be revealed on US, CT or MRI scans. The US appearance exhibited a hyper echoic arc zone with broad clean acoustic shadow behind. It appeared as a soft tissue mass to CT and MRI scans. In early stage CT scan could easily show the gas within the crumpled gauze. CT and MRI enhanced scans showed only the enhanced membrane and no enhancement of the crumpled gauze. Conclusion: US, CT and MRI have quite characteristic appearances of the abdominally retained crumpled gauze, especially when combined imaging techniques were employed, which can lead to a correct diagnosis together with a history of operation

  13. Retained Surgical Foreign Bodies after Surgery

    Directory of Open Access Journals (Sweden)

    Valon A. Zejnullahu

    2017-01-01

    Full Text Available The problem of retained surgical bodies (RSB after surgery is an issue for surgeons, hospitals and the entire medical team. They have potentially harmful consequences for the patient as they can be life threatening and usually, a further operation is necessary. The incidence of RSB is between 0.3 to 1.0 per 1,000 abdominal operations, and they occur due to a lack of organisation and communication between surgical staff during the process. Typically, the RSB are surgical sponges and instruments located in the abdomen, retroperitoneum and pelvis.

  14. DETERMINANTS OF RETAINED EARNINGS IN PROFITABLE STEEL COMPANIES IN INDIA: A STUDY OF STEEL SECTOR

    OpenAIRE

    Dr. Sohaib Masood

    2018-01-01

    In this paper an attempt has been made to identify the important determinants of retained earnings in profitable steel companies in steel sector of India and which have impact on the retention of earnings of steel companies under study. Multiple linear regression is used to identify the determinants of retained earnings for a period of sixteen years. Also the importance of retained earnings as a source of finance for steel sector companies is also studied in the paper.

  15. Reproductive performance of Friesian mares after retained placenta and manual removal of the placenta

    NARCIS (Netherlands)

    Sevinga, M; Hesselink, JW; Barkema, H.W.

    2002-01-01

    Because the incidence of retained placenta in Friesian mares is estimated to be high, and no reports have been published on the reproductive performance of Friesian mares after retained placenta, we studied postpartum reproductive performance in Friesian brood mares with (n = 54) and without (n =

  16. Assessment of Candida species colonization and denture-related stomatitis in bar- and locator-retained overdentures.

    Science.gov (United States)

    Kilic, Kerem; Koc, Ayse Nedret; Tekinsen, Fatma Filiz; Yildiz, Pinar; Kilic, Duygu; Zararsiz, Gokmen; Kilic, Erdem

    2014-10-01

    The aim of this study was to assess the prevalence of denture-related stomatitis (DRS) in different attachment-retained overdenture wearers and its association with particular colonizing Candida species. Thirty-seven edentulous patients with implant-supported maxillary or mandibular overdentures were enrolled. A full clinical history was obtained, including details of patients' oral hygiene practices and the levels of erythema based on Newton's classification scale. Swabs were taken from the palate and investigated mycologically to identify the yeast colonies. Quantitative and qualitative microbiological assessments were performed, which included recording the total numbers of colonies (cfu), their color, and their morphological characteristics. Significant differences were found in cfu values between the attachment and inner surfaces of locator- and bar-retained overdentures (P overdentures and 38.1% of locator-retained overdentures. DRS developed in all patients using bar-retained overdentures but in only 71.4% of those using locator-retained overdentures. No statistically significant relationship was found between bar and locator attachments according to smoking habit, overnight removal, or plaque and gingival indices (P > .05).

  17. Revised design for the Tokamak experimental power reactor

    International Nuclear Information System (INIS)

    Stacey, W.M. Jr.; Abdou, M.A.; Brooks, J.N.

    1977-03-01

    A new, preliminary design has been identified for the tokamak experimental power reactor (EPR). The revised EPR design is simpler, more compact, less expensive and has somewhat better performance characteristics than the previous design, yet retains many of the previously developed design concepts. This report summarizes the principle features of the new EPR design, including performance and cost

  18. Indirect vs direct bonding of mandibular fixed retainers in orthodontic patients: Comparison of retainer failures and posttreatment stability. A 2-year follow-up of a single-center randomized controlled trial.

    Science.gov (United States)

    Egli, Fabienne; Bovali, Efstathia; Kiliaridis, Stavros; Cornelis, Marie A

    2017-01-01

    The objectives of this 2-arm parallel trial were to compare the numbers of failures of mandibular fixed retainers bonded with indirect and direct methods and to investigate the posttreatment changes 2 years after placement. Sixty-four consecutive patients from the postgraduate orthodontic clinic of the University of Geneva in Switzerland were randomly allocated to either an indirect or a traditional direct bonding procedure of a mandibular fixed retainer at the end of their orthodontic treatment (T0). Eligibility criteria were the presence of the 4 mandibular incisors and the 2 mandibular canines, and no active caries, restorations, fractures, or periodontal disease of these teeth. The patients were randomized in blocks of 4 (using an online randomization service) with allocation concealment secured by contacting the sequence generator for assignment. The patients were recalled 12 months and 24 months (T3) after retainer bonding. The main outcome was any first-time failure of retainers (ie, at least 1 composite pad debonded or fractured); unexpected posttreatment changes of the mandibular incisors and canines were a secondary outcome. Impressions and lateral cephalograms were taken at T0 and T3: changes in mandibular intercanine and interpremolar distances and mandibular incisor inclination were assessed. Blinding was applicable for outcome assessment only. The chi-square test and Cox regression were used to compare the survival rates of the retainers bonded with direct and indirect methods. Paired t tests were used to assess differences in intercanine and interpremolar distances and mandibular incisor inclination at T0 and T3. Significance was set at P direct bonding group (log-rank test, P = 0.64). The hazard ratio was 1.26 (95% confidence interval, 0.56-2.81; P = 0.58). Bond failures occurred mainly during the first year. There were no clinically significant changes in mandibular intercanine distance, interpremolar distance, and incisor inclination

  19. Experimental assessment of dry stone retaining wall stability on a rigid foundation

    OpenAIRE

    Villemus , B.; Morel , J.C.; Boutin , C.

    2007-01-01

    International audience; Dry stone masonry retaining walls are present in the majority of mountainous areas all around the world, but the technique is marginal today in developed countries. The emergence of the concept of sustainable development calls for renewed use of this technique, both for the repair of existing retaining walls and the building of new ones. The objective of this research was to seek the knowledge necessary to ensure the stability of these structures, using experimental in...

  20. Retained placenta in Friesian mares : reproductive performance after foal heat breeding versus breeding in a subsequent heat

    NARCIS (Netherlands)

    Sevinga, M; Hesselink, JW; Barkema, H.W.

    2001-01-01

    Postpartum reproductive performance was studied in 54 Friesian brood mares with and 50 without retained placenta. Retained placenta was defined as failure to expel all fetal membranes within 3 hours after the delivery of the foal. The group of mares with retained placenta was subdivided into mares

  1. The effect of retained intramedullary nails on tibial bone mineral density.

    Science.gov (United States)

    Allen, J C; Lindsey, R W; Hipp, J A; Gugala, Z; Rianon, N; LeBlanc, A

    2008-07-01

    Intramedullary nailing has become a standard treatment for adult tibial shaft fractures. Retained intramedullary nails have been associated with stress shielding, although their long-term effect on decreasing tibial bone mineral density is currently unclear. The purpose of this study was to determine if retained tibial intramedullary nails decrease tibial mineral density in patients with successfully treated fractures. Patients treated with statically locked intramedullary nails for isolated, unilateral tibia shaft fractures were studied. Inclusion required that fracture had healed radiographically and that the patient returned to the pre-injury activity level. Data on patient demographic, fracture type, surgical technique, implant, and post-operative functional status were tabulated. Dual energy X-ray absorptiometry was used to measure bone mineral density in selected regions of the affected tibia and the contralateral intact tibia. Image reconstruction software was employed to ensure symmetry of the studied regions. Twenty patients (mean age 43; range 22-77 years) were studied at a mean of 29 months (range 5-60 months) following intramedullary nailing. There was statistically significant reduction of mean bone mineral density in tibiae with retained intramedullary nails (1.02 g/cm(2) versus 1.06 g/cm(2); P=0.04). A significantly greater decrease in bone mineral density was detected in the reamed versus non-reamed tibiae (-7% versus +6%, respectively; P<0.05). The present study demonstrates a small, but statistically significant overall bone mineral density decrease in healed tibiae with retained nails. Intramedullary reaming appears to be a factor potentiating the reduction of tibia bone mineral density in long-term nail retention.

  2. Torque resistance of different stainless steel wires commonly used for fixed retainers in orthodontics

    DEFF Research Database (Denmark)

    Arnold, Dario; Dalstra, Michel; Verna, Carlalberta

    2016-01-01

    Objective: Movements of teeth splinted by fixed retention wires after orthodontic treatment have been observed. The aetiological factors for these movements are unknown. The aim of this in vitro study was to compare the resistance to torque of different stainless steel wires commonly used for fixed...... retainers in orthodontics. Materials and Methods: Torquing moments acting on a retainer wire were measured in a mechanical force testing system by applying buccal crown torque to an upper lateral incisor in both a 3-teeth and in a 2-teeth setup. Seven stainless steel wires with different shape, type (plain...... or a braided 0.016 × 0.022-inch stainless steel wire. A tooth attached by a retainer wire to only one neighbouring tooth is less resistant to torque than a tooth connected to two neighbouring teeth. Annealing a retainer wire with a flame reduces the stiffness of the wire markedly and can lead to a non...

  3. Implant-Retained Auricular Prosthesis: A Case Report

    OpenAIRE

    Ozturk, A. Nilgun; Usumez, Aslihan; Tosun, Zekeriya

    2010-01-01

    Extraoral implant retained prosthesis have been proven to be a predictable treatment option for maxillofacial rehabilitation. This case report describes the clinical and laboratory procedures for fabricating an auricular prosthesis. In this case report, an auricular prosthesis was fabricated for a patient who lost the left and right external ear in an electrical burn. Extraoral implants and bar-and-clip retention for the proper connection of the auricular prosthesis to implant were used. This...

  4. 40 CFR 98.57 - Records that must be retained.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Records that must be retained. 98.57 Section 98.57 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...) Documentation of how process knowledge was used to estimate abatement technology destruction efficiency. (f...

  5. 41 CFR 102-42.25 - Who retains custody of gifts and decorations pending disposal?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Who retains custody of gifts and decorations pending disposal? 102-42.25 Section 102-42.25 Public Contracts and Property..., Handling and Disposition § 102-42.25 Who retains custody of gifts and decorations pending disposal? (a) The...

  6. 75 FR 11207 - Policy Statement on Obtaining and Retaining Beneficial Ownership Information for Anti-Money...

    Science.gov (United States)

    2010-03-10

    ... Retaining Beneficial Ownership Information for Anti-Money Laundering Purposes AGENCY: Securities and...-money laundering purposes. DATES: Effective Date: March 5, 2010. FOR FURTHER INFORMATION CONTACT... retaining beneficial ownership information for anti-money laundering purposes. This guidance is being issued...

  7. CT Findings of Foreign Body Reaction to a Retained Endoloop Ligature Plastic Tube Mimicking Acute Appendicitis: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Jae Hong; Kang, Chae Hoon; Choi, Soo-Jung; Park, Man Soo; Jung, Seung Mun; Ryu, Dae Shick; Shin, Dong Rock [Department of Radiology, Asan Foundation, GangNeung Asan Hospital, University of Ulsan College of Medicine, Gangneung 25440 (Korea, Republic of)

    2016-11-01

    Many hospitals experience one or more retained surgical instrument events with risk of patient morbidity and medicolegal problems. Identification of retained surgical instrument is important. The radiologists should be familiar with imaging finding of retained surgical instrument. In a 62-year-old female with a retained plastic tube, localized peritoneal infiltration around air-containing tubular structure mimicked acute appendicitis on abdomen computed tomography (CT), one year after laparoscopic cholecystectomy. We reported CT findings of foreign body reaction related to retained Endoloop ligature plastic tube mimicking acute appendicitis.

  8. Failure Rates of Orthodontic Fixed Lingual Retainers bonded with Two Flowable Light-cured Adhesives: A Comparative Prospective Clinical Trial.

    Science.gov (United States)

    Talic, Nabeel F

    2016-08-01

    This comparative prospective randomized clinical trial examined the in vivo failure rates of fixed mandibular and maxillary lingual retainers bonded with two light-cured flowable composites over 6 months. Consecutive patients were divided into two groups on a 1:1 basis. Two hundred fixed lingual retainers were included, and their failures were followed for 6 months. One group (n = 50) received retainers bonded with a nano-hybrid composite based on nano-optimized technology (Tetric-N-Flow, Ivoclar Vivadent). Another group (n = 50) received retainers bonded with a low viscosity (LV) composite (Transbond Supreme LV, 3M Unitek). There was no significant difference between the overall failure rates of mandibular retainers bonded with Transbond (8%) and those bonded with Tetric-N-Flow (18%). However, the odds ratio for failure using Tetric-N-flow was 2.52-fold greater than that of Transbond. The failure rate of maxillary retainers bonded with Transbond was higher (14%), but not significantly different, than that of maxillary retainers bonded with Tetric-N-flow (10%). There was no significant difference in the estimated mean survival times of the maxillary and mandibular retainers bonded with the two composites. Both types of composites tested in the current study can be used to bond fixed maxillary and mandibular lingual retainers, with low failure rates.

  9. RESTOP: Retaining External Peripheral State in Intermittently-Powered Sensor Systems.

    Science.gov (United States)

    Rodriguez Arreola, Alberto; Balsamo, Domenico; Merrett, Geoff V; Weddell, Alex S

    2018-01-10

    Energy harvesting sensor systems typically incorporate energy buffers (e.g., rechargeable batteries and supercapacitors) to accommodate fluctuations in supply. However, the presence of these elements limits the miniaturization of devices. In recent years, researchers have proposed a new paradigm, transient computing, where systems operate directly from the energy harvesting source and allow computation to span across power cycles, without adding energy buffers. Various transient computing approaches have addressed the challenge of power intermittency by retaining the processor's state using non-volatile memory. However, no generic approach has yet been proposed to retain the state of peripherals external to the processing element. This paper proposes RESTOP, flexible middleware which retains the state of multiple external peripherals that are connected to a computing element (i.e., a microcontroller) through protocols such as SPI or I 2 C. RESTOP acts as an interface between the main application and the peripheral, which keeps a record, at run-time, of the transmitted data in order to restore peripheral configuration after a power interruption. RESTOP is practically implemented and validated using three digitally interfaced peripherals, successfully restoring their configuration after power interruptions, imposing a maximum time overhead of 15% when configuring a peripheral. However, this represents an overhead of only 0.82% during complete execution of our typical sensing application, which is substantially lower than existing approaches.

  10. Comparison of Stability of the Results of Orthodontic Treatment and Gingival Health between Hawley and Vacuum-formed Retainers.

    Science.gov (United States)

    Moslemzadeh, Seyed H; Sohrabi, Aydin; Rafighi, Ali; Farshidnia, Somaieh

    2018-04-01

    Aim: Retention is one of the stages of orthodontic treatment, which is an attempt to retain teeth in their corrected positions after active treatment with the use of fixed orthodontic appliances. The aim of the present study was to compare the stability of the results of orthodontic treatment and the gingival health between Hawley retainer (HR) and vacuum-formed retainer (VFR) with two different thicknesses. Materials and methods: In this randomized clinical trial, 66 patients undergoing comprehensive orthodontic treatment in a private office were evaluated after completion of treatment. The subjects were randomly assigned to three groups. At the end of orthodontic treatment, the subjects in all the groups received a fixed bonded retainer in the mandible; in the maxilla, group I received an HR, group II received a VFR with a thickness of 1.5 mm, and group III received a VFR with a thickness of 1 mm. The American Board of Orthodontics objective grading system (ABO-OGS) index was used at the end of treatment (before the delivery of the retainers) and 6 months after the use of retainers to evaluate the stability of the results of orthodontic treatment. Gingival index (GI) was used at the two above-mentioned intervals to evaluate gingival health. The ABO-OGS measurements were carried out on dental casts by a clinician who was blinded to the types of retainers the patients wore. Data were analyzed with Statistical Package for the Social Sciences (SPSS) version 20, using proper statistical analyses. Results: Six months after the delivery of retainers, ABO-OGS and GI scores with the 1.5 mm VFR were higher than those in the two other groups, with no significant differences between the three groups. There were no significant differences between the ABO-OGS scores before the delivery of retainers and 6 months after the use of retainers in any of the study groups. In the HR and 1.5 mm VFR groups, there were significant differences in GI scores between the period before the

  11. Low-mass X-ray binaries from black hole retaining globular clusters

    Science.gov (United States)

    Giesler, Matthew; Clausen, Drew; Ott, Christian D.

    2018-06-01

    Recent studies suggest that globular clusters (GCs) may retain a substantial population of stellar-mass black holes (BHs), in contrast to the long-held belief of a few to zero BHs. We model the population of BH low-mass X-ray binaries (BH-LMXBs), an ideal observable proxy for elusive single BHs, produced from a representative group of Milky Way GCs with variable BH populations. We simulate the formation of BH binaries in GCs through exchange interactions between binary and single stars in the company of tens to hundreds of BHs. Additionally, we consider the impact of the BH population on the rate of compact binaries undergoing gravitational wave driven mergers. The characteristics of the BH-LMXB population and binary properties are sensitive to the GCs structural parameters as well as its unobservable BH population. We find that GCs retaining ˜1000 BHs produce a galactic population of ˜150 ejected BH-LMXBs, whereas GCs retaining only ˜20 BHs produce zero ejected BH-LMXBs. Moreover, we explore the possibility that some of the presently known BH-LMXBs might have originated in GCs and identify five candidate systems.

  12. Low-mass X-ray binaries from black-hole retaining globular clusters

    Science.gov (United States)

    Giesler, Matthew; Clausen, Drew; Ott, Christian D.

    2018-03-01

    Recent studies suggest that globular clusters (GCs) may retain a substantial population of stellar-mass black holes (BHs), in contrast to the long-held belief of a few to zero BHs. We model the population of BH low-mass X-ray binaries (BH-LMXBs), an ideal observable proxy for elusive single BHs, produced from a representative group of Milky Way GCs with variable BH populations. We simulate the formation of BH-binaries in GCs through exchange interactions between binary and single stars in the company of tens to hundreds of BHs. Additionally, we consider the impact of the BH population on the rate of compact binaries undergoing gravitational wave driven mergers. The characteristics of the BH-LMXB population and binary properties are sensitive to the GCs structural parameters as well as its unobservable BH population. We find that GCs retaining ˜1000 BHs produce a galactic population of ˜150 ejected BH-LMXBs whereas GCs retaining only ˜20 BHs produce zero ejected BH-LMXBs. Moreover, we explore the possibility that some of the presently known BH-LMXBs might have originated in GCs and identify five candidate systems.

  13. Kinked and retained nasogastric tube in polytrauma patient; a case report

    Directory of Open Access Journals (Sweden)

    Kumar Ashok

    2017-06-01

    Full Text Available Enteral feeding is an important and preferred technique of feeding in head injury patient to provide nutrition. As inadequate nutrition causes decrease in physical ability, neurological impairment and takes a long time for improvement or delayed deterioratation. With our best knowledge kinked and retained nasogastric tube in stomach is a very rare complication of feeding in head injuries patients. Predisposing factors that can cause kinking is excess tube length, tube in situ for long time and small bore tube. We are reporting one such case of kinked and retained nasogastric tube in the stomach of a polytrauma patient which was retrieved by upper GI endoscope.

  14. 40 CFR 98.227 - Records that must be retained.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Records that must be retained. 98.227 Section 98.227 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... significant changes to process. (b) Documentation of how process knowledge was used to estimate abatement...

  15. Using Blue Stragglers to Predict Retained Black Hole Population in Globular Clusters

    Science.gov (United States)

    Hermanek, Keith; Chatterjee, Sourav; Rasio, Frederic

    2018-01-01

    Large numbers of black holes (BHs) are expected to form in massive star clusters typical of the globular clusters (GCs). Sophisticated theoretical models suggest that many of these BHs can be retained in present-day GCs. Observations have also identified several BH candidates in Galactic and extragalactic GCs (e.g., Macarone et al. 2007; Irwin et al. 2010; Strader et al. 2012; Chomiuk et al. 2013; Miller-Jones et al. 2014). It has also been shown that high-mass and high-density clusters such as GCs are efficient factories of merging binary BHs similar to those observed by the LIGO observatories (Abbott et al. 2016a,b,c,d,e; Rodriguez et al. 2016). Understanding the formation rate and properties of binary BHs are dependent on a detailed understanding of how the BHs dynamically evolve within GCs. Nevertheless, directly detecting BHs in GCs is extremely challenging; BHs only in binaries with limited configurations can be directly detected by the detection of gravitational wave, X-ray, or radio emissions. We propose an indirect of inferring the number of undetected retained BHs in a GC by investigating the dynamical effects of a large number of BHs on the production of other tracer populations such as Blue Straggler Stars (BSS). Using a large grid of detailed GC models we show that there is a clear anti-correlation between the number of BSS in a cluster and the number of retained BHs. Being the most massive species, large numbers of retained BHs will dominate the core of the cluster as a result of mass-segregation driving away other low-mass species such as main-sequence stars from central high-density regions. BSS are expected to form from physical collisions between main-sequence (MS) stars mediated by binary encounters (e.g., Chatterjee et al. 2013) in cores of GCs. Production of BSS by collisions or mass transfer channels are suppressed if a large number of retained BHs in a cluster restrict the number of MS stars in the core. Extensive observational data exist on

  16. Retained austenite thermal stability in a nanostructured bainitic steel

    International Nuclear Information System (INIS)

    Avishan, Behzad; Garcia-Mateo, Carlos; Yazdani, Sasan; Caballero, Francisca G.

    2013-01-01

    The unique microstructure of nanostructured bainite consists of very slender bainitic ferrite plates and high carbon retained austenite films. As a consequence, the reported properties are opening a wide range of different commercial uses. However, bainitic transformation follows the T 0 criteria, i.e. the incomplete reaction phenomena, which means that the microstructure is not thermodynamically stable because the bainitic transformation stops well before austenite reaches an equilibrium carbon level. This article aims to study the different microstructural changes taking place when nanostructured bainite is destabilized by austempering for times well in excess of that strictly necessary to end the transformation. Results indicate that while bainitic ferrite seems unaware of the extended heat treatment, retained austenite exhibits a more receptive behavior to it. - Highlights: • Nanostructured bainitic steel is not thermodynamically stable. • Extensive austempering in these microstructures has not been reported before. • Precipitation of cementite particles is unavoidable at longer austempering times. • TEM, FEG-SEM and XRD analysis were used for microstructural characterization

  17. Retained austenite thermal stability in a nanostructured bainitic steel

    Energy Technology Data Exchange (ETDEWEB)

    Avishan, Behzad, E-mail: b_avishan@sut.ac.ir [Faculty of Materials Engineering, Sahand University of Technology, Tabriz (Iran, Islamic Republic of); Garcia-Mateo, Carlos, E-mail: cgm@cenim.csic.es [Department of Physical Metallurgy, National Centre for Metallurgical Research (CENIM-CSIC), MATERALIA Research Group, Avda. Gregorio del Amo, 8, 28040, Madrid (Spain); Yazdani, Sasan, E-mail: yazdani@sut.ac.ir [Faculty of Materials Engineering, Sahand University of Technology, Tabriz (Iran, Islamic Republic of); Caballero, Francisca G., E-mail: fgc@cenim.csic.es [Department of Physical Metallurgy, National Centre for Metallurgical Research (CENIM-CSIC), MATERALIA Research Group, Avda. Gregorio del Amo, 8, 28040, Madrid (Spain)

    2013-07-15

    The unique microstructure of nanostructured bainite consists of very slender bainitic ferrite plates and high carbon retained austenite films. As a consequence, the reported properties are opening a wide range of different commercial uses. However, bainitic transformation follows the T{sub 0} criteria, i.e. the incomplete reaction phenomena, which means that the microstructure is not thermodynamically stable because the bainitic transformation stops well before austenite reaches an equilibrium carbon level. This article aims to study the different microstructural changes taking place when nanostructured bainite is destabilized by austempering for times well in excess of that strictly necessary to end the transformation. Results indicate that while bainitic ferrite seems unaware of the extended heat treatment, retained austenite exhibits a more receptive behavior to it. - Highlights: • Nanostructured bainitic steel is not thermodynamically stable. • Extensive austempering in these microstructures has not been reported before. • Precipitation of cementite particles is unavoidable at longer austempering times. • TEM, FEG-SEM and XRD analysis were used for microstructural characterization.

  18. A new approach to incisor retention--the lingual spur retainer.

    LENUS (Irish Health Repository)

    McNamara, T G

    1996-08-01

    Late lower incisor crowding and incisor rotations remain a problem in orthodontics. We describe a new fixed retainer which is simple to use, allows physiological tooth movement, but prevents rotational and labio-lingual relapse.

  19. MULTIPLE RETAINED TEETH IN MANDIBLE: A Case Report

    Directory of Open Access Journals (Sweden)

    Cvetan Cvetanov

    2010-07-01

    Full Text Available Purpose: The aim of this science report is to show a rare case of multiple impacted teeth at adult patient and our propose clinical approach.Materials and methods: The clinical case is showed from adult man /64-year old/ with multiple impacted teeth (6 impacted teeth in the anterior place on the mandible were not suggestive of any syndrome or metabolic disorder. The extraction of the impacted teeth was made on two stage with piezosurgery unit under local anaesthesia. For prevention of postsurgical complications, as a swelling and prevention of postsurgical resorbtion were used coneshapes from pressure xeno colagen. To base on clinical and radiological examination we will discuss the differential diagnosis and we will offer a clinical approach about decided the case.Result and Conclusion: The incidence of multiple retained teeth by literature research range from 10.9% to 40.4%, most frequently is the retention of the third molars. In the literature most rarely have clinical reports about multiple retained teeth which differ from third molars at adult patients. The rare clinical case we showed is very demonstrative and the medicative approach which we used gave excellent result.

  20. 75 FR 81587 - Coding of Design Marks in Registrations

    Science.gov (United States)

    2010-12-28

    ... DEPARTMENT OF COMMERCE Patent and Trademark Office [Docket No. PTO-T-2010-0090] Coding of Design... discontinue its secondary design coding, the practice of coding newly registered trademarks in its searchable... temporarily retain the paper collection of registrations with design coding, while improving the accuracy of...

  1. Retained Foreign Bodies: A Serious Threat in the Indian Operation ...

    African Journals Online (AJOL)

    hanumantp

    report cases of RFBs. Keywords: Medical negligence, Radiography, Retained foreign bodies. Review Article ... different technology used to reduce medical errors was included in this review. ..... body mimicking a spinal mass. Eur Spine J 2006 ...

  2. A rare case report of hysterotomy for retained placenta accreta in bicornuate uterus

    OpenAIRE

    Reena Sharma; Amit Gupta; Usha K. Chaudhary; Ajay Sharma; Arvind Kumar

    2015-01-01

    Retained placenta is a common third stage complication. Placenta accreta is due to abnormal invasive placental implantation. Many cases of Post-partum haemorrhage (PPH) are caused by placenta accreta and may lead to peripartum hysterectomy. We here report a case of placenta accreta in a patient following two failed attempts of manual removal of retained placenta followed by conservative management with methotrexate in stable patient. Both attempts were unsuccessful and led to septicaemia, req...

  3. Supporting workers with mental health problems to retain employment: users' experiences of a UK job retention project.

    Science.gov (United States)

    Cameron, Josh; Walker, Carl; Hart, Angie; Sadlo, Gaynor; Haslam, Imogen; Retain Support Group

    2012-01-01

    To understand experiences and perspectives of job retention project users in relation to challenges faced and support received; to develop explanatory insight into effective interventions. 14 employed users of a United Kingdom job retention project, with a range of mental health problems. Semi-structured individual interviews which were collaboratively designed with service users. Data analysis involved deductive & inductive thematic analysis, constant comparative analysis, and service user collaboration. Participants' feelings of guilt and self blame were a major obstacle to job retention. The project helped them address these by supporting a reappraisal of their situation. This assisted identification of job accommodations and adjustments and confidence in self advocacy. Thus an important basis for improved dialogue with their employer was established. A peer support group provided an important adjunct to individual project worker interventions. 10 participants retained employment; three of those who did not were helped to retain work aspirations. The project effectively used a multi-faceted approach involving a person - environment-occupation focus on the worker, their work, and workplace. Such complex interventions may offer more promise than those interventions (such as cognitive behavioural therapy) which have a primary focus on the individual worker.

  4. Fracture resistance of direct inlay-retained adhesive bridges : Effect of pontic material and occlusal morphology

    NARCIS (Netherlands)

    Breuklander, Marijn; Salihoglu-Yener, Esra; Ozcan, Mutlu

    This study evaluated the effect of a) pontic materials and b) occlusal morphologies on the fracture resistance of fiber-reinforced composite (FRC) inlay-retained fixed dental prostheses (FDP). Inlay-retained FRC FPDs (N=45, n=9) were constructed using a) resin composite (deep anatomy), b) natural

  5. Vesicovaginal fistula, bladder calculus, retained foreign body or all ...

    African Journals Online (AJOL)

    L. Paik

    Vesicovaginal fistula, bladder calculus, retained foreign body or all of the above? The unusual presentation of a female with total urinary incontinence. L. Paika, S. Smitb,∗. , H. van Heerdenb, K. du Toitb,. A. van der Merweb, C. Heynsb a Department of Urology, Michigan State University College of Osteopathic Medicine, ...

  6. Finite element analysis to compare complete denture and implant-retained overdentures with different attachment systems.

    Science.gov (United States)

    Barão, Valentim Adelino Ricardo; Assunção, Wirley Gonçalves; Tabata, Lucas Fernando; Delben, Juliana Aparecida; Gomes, Erica Alves; de Sousa, Edson Antonio Capello; Rocha, Eduardo Passos

    2009-07-01

    This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred in supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

  7. Rehabilitation of resorbed mandibular ridges using mini implant retained overdentures: A case series with 3 year follow-up

    Directory of Open Access Journals (Sweden)

    Pooja Kumari

    2016-01-01

    Full Text Available With the increasing average life expectancy of human beings, the need to cater geriatric patients is ever increasing. Complete dentures are an indispensable tool in this regard. The loose and unstable lower complete denture owing to residual ridge resorption is one of the most common problems faced by edentulous patients. Dental implant retained overdentures have emerged as an efficient treatment modality for such patients. Though useful, not every patient is a suitable candidate to go for conventional implant-borne prosthesis, limitation being the available bone width. In such cases, mini implants may be used for augmenting the retention of the dentures and improving the quality of life of patients. In this case series, rehabilitation of three compromised cases with mini implant retained overdentures have been described wherein patients are experiencing instability of lower denture due to thin resorbed mandibular ridges. In one of the cases, three mini implants placed in A, C, and E position were splinted using a cemented bar to retain the mandibular denture. The other two cases were rehabilitated using unsplinted ball type one piece mini implants placed in A, C, and E position in one case and B and D position in another case. Though splinted bar design should be preferred but the lack of available vertical space precluded the utilization of bar in other two cases. The results were found to be satisfactory with no complications reported during a follow-up period of over 3 years in all the cases.

  8. Masticatory performance and chewing experience with implant-retained mandibular overdentures

    NARCIS (Netherlands)

    Geertman, ME; Slagter, AP; van't Hof, MA; van Waas, MAJ; Kalk, W

    The relationship between masticatory performance and chewing experience has not yet been explored for patients with implant-retained overdentures. Although many relationships have been found between parameters of objective and subjective oral function, the structure of these relationships remain

  9. Evaluation of the Mechanical Behavior of a Retaining Wall Structure on a Weathered Soil through Probabilistic Methods

    OpenAIRE

    P. V. S. Mascarenhas; B. C. P. Albuquerque; D. J. F. Campos; L. L. Almeida; V. R. Domingues; L. C. S. M. Ozelim

    2017-01-01

    Retaining slope structures are increasingly considered in geotechnical engineering projects due to extensive urban cities growth. These kinds of engineering constructions may present instabilities over the time and may require reinforcement or even rebuilding of the structure. In this context, statistical analysis is an important tool for decision making regarding retaining structures. This study approaches the failure probability of the construction of a retaining wall over the debris of an ...

  10. Control of pH of retained water in the coastal waste disposal site

    Directory of Open Access Journals (Sweden)

    Hem Ramrav

    2018-01-01

    Full Text Available After landfilling of wastes is completed, the stabilization of landfilled ground requires much time and cost. Therefore, this study aimed to control the pH of retained water in the coastal waste disposal sites during landfilling process, by conducting field surveys and laboratory experiments. In field surveys, we investigated the changes of retained water quality such as pH, salinity, and dissolved oxygen. The results show the pH of retained water has risen to about 10 when the volume of landfilled wastes reached about 25% of landfill capacity. In lowing the pH, we considered a low-cost method by pumping seawater from the adjacent sea into the landfill. The mechanism in this method is that, H+ dissociated from HCO3- in the fresh seawater react with OH- eluted from wastes would result in pH decrease. The laboratory experiments were conducted to verify the effect on pH change by adding fresh seawater to alkalized seawater. As a result, the effect of injecting fresh seawater into alkalized seawater with pH higher than 9 was confirmed. Therefore, this treatment method is suggested to enable the disposal sites to be used promptly after landfilling is completed, by adding fresh seawater to purify the retained water and waste at low cost during landfilling process.

  11. An Innovative Approach for Gob-Side Entry Retaining in Thick Coal Seam Longwall Mining

    Directory of Open Access Journals (Sweden)

    Manchao He

    2017-11-01

    Full Text Available Gob-side entry retaining (GER is a popular non-pillar mining technique regarding how to reserve a gateroad for the use of next panel mining. When used in thick coal seams, the conventional entry retaining method requires a huge amount of filling materials and may cause entry (gateroad accidents. Thus, an innovative non-pillar longwall mining approach is introduced. First, structural and mechanical models were built to explore the mechanism of the new approach. The modeling results indicate that effective bulking of the gob roof and reasonable support of the entry roof were key governing factors in improving entry stabilities and reducing roof deformations. Accordingly, a directional roof fracturing technique was proposed to contribute to gob roof caving, and a constant resistance and large deformation anchor (CRLDA cable was used to stabilize the entry roof. Subsequently, the evolutionary laws of the roof structure and stresses were explored using numerical simulation. It was found that the structure of the surrounding rocks around the retained entry changed significantly after roof fracturing. The stress-bearing center was transferred to the gob area, and the entry roof was in a low stress environment after adopting the approach. Finally, the approach was tested on a thick coal seam longwall mining panel. Field monitoring indicates that the retained entry was in a stable state and the index of the retained entry met the requirement of the next mining panel. This work provides an effective and economical approach to non-pillar longwall mining in thick coal seams.

  12. Comparison of Wear Resistance of Hawley and Vacuum Formed Retainers: An in-vitro Study.

    Science.gov (United States)

    V, Moshkelgosha; M, Shomali; M, Momeni

    2016-06-01

    As a physical property, wear resistance of the materials used in the fabrication of orthodontic retainers play a significant role in the stability and long term use of the appliances. To evaluate the wear resistance of two commonly used materials for orthodontic retainers: Acropars OP, i.e. a polymethyl methacrylate based material, and 3A-GS060, i.e. a polyethylene based material. For each material, 30 orthodontic retainers were made according to the manufacturers' instructions and a 30×30×2 mm block was cut out from the mid- palatal area of each retainer. Each specimen underwent 1000 cycles of wear stimulation in a pin on disc machine. The depth of wear of each specimen was measured using a Nano Wizard II atomic force microscope in 3 random points of each specimen's wear trough. The average of these three measurements was calculated and considered as mean value wear depth of each specimen (µm). The mean wear depth was 6.10µm and 2.15µm for 3A-GS060 and Acropars OP groups respectively. Independent t-test showed a significant difference between the two groups ( p < 0.001). The results show Polymethyl methacrylate base (Acropars) is more wear resistance than the polyethylene based material (3A-GS060). As the higher wear resistance of the fabrication material can improve the retainers' survival time and its cost-effectiveness, VFRs should be avoided in situations that the appliance needs high wear resistance such as bite blocks opposing occlusal forces.

  13. 9 CFR 318.15 - Tagging chemicals, preservatives, cereals, spices, etc., “U.S. retained.”

    Science.gov (United States)

    2010-01-01

    ..., cereals, spices, etc., âU.S. retained.â 318.15 Section 318.15 Animals and Animal Products FOOD SAFETY AND...; REINSPECTION AND PREPARATION OF PRODUCTS General § 318.15 Tagging chemicals, preservatives, cereals, spices, etc., “U.S. retained.” When any chemical, preservative, cereal, spice, or other substance is intended...

  14. Assessment of Soil Arching Factor for Retaining Wall Pile Foundations

    Science.gov (United States)

    2017-03-31

    Despite the prevalence of the soldier piles retaining wall systems as temporary and even permanent shoring systems along state highways, relatively little is known on the effect of the foreslope bench width and the slope inclination on the arching ca...

  15. Management of retained encrusted urethral catheter with extracorporeal shockwave lithotripsy

    Directory of Open Access Journals (Sweden)

    Sameh Anwar Kunzman

    2002-01-01

    Full Text Available We report a case of non-deflating heavily encrusted Foley catheter successfully removed by extracorporeal shockwave lithotripsy (ESWL. To our knowledge this is the first case of using ESWL to remove encrusted foley catheter retained in the bladder.

  16. Retained portion of latex glove during femoral nailing. Case report.

    Science.gov (United States)

    Sadat-Ali, M; Marwah, S; al-Habdan, I

    1996-11-01

    A case of retained glove during Kuntscher intramedullary nailing is described. An abscess around the glove could have lead to osteomyelitis. One need to be cautious feeling the top end of the nail while femoral nailing to avoid such a complication.

  17. 12 CFR 714.6 - Are you required to retain salvage powers over the leased property?

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Are you required to retain salvage powers over the leased property? 714.6 Section 714.6 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING CREDIT UNIONS LEASING § 714.6 Are you required to retain salvage powers over the leased...

  18. 5 CFR 536.307 - Treatment of a retained rate as basic pay for other purposes.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Treatment of a retained rate as basic pay... CIVIL SERVICE REGULATIONS GRADE AND PAY RETENTION Pay Retention § 536.307 Treatment of a retained rate... for accumulated and annual leave under 5 CFR part 550, subpart L; (8) General Schedule pay...

  19. Effect of tightening torque on the marginal adaptation of cement-retained implant-supported fixed dental prostheses

    Directory of Open Access Journals (Sweden)

    Jalil Ghanbarzadeh

    2015-01-01

    Conclusion: Within the limitations of this study, the marginal misfit of cement-retained FDPs increased continuously when the tightening torque increased. After cutting the connectors, the marginal misfit of the ANRs was higher than those of the straight abutment retainers.

  20. Dividend Per Share, Retained Earnings, Book Value And Total Debt On Stock Price: Approximation Valuation Model Dividend Per Share, Retained Earnings, Book Value, dan Total Debt terhadap Harga Saham: Pendekatan Valuation Model.

    OpenAIRE

    khikmah, Khoirul

    2011-01-01

    This study examines to dividend per share, retained earnings, book valueand total debt on stock price: approximation valuation model. Data in this studyare manufacture firms listed on Indonesia Stock Exchange in 2005 – 2008. Linearregression analysis used to analysis this data. Result of regression analysis findsthat dividend per share, retained earnings, book value and total debt on stock pricehave significant effect to stock price. Dividend per share and book value havesignificant effect in...

  1. Transabdominal Migration of Retained Surgical Sponge

    Directory of Open Access Journals (Sweden)

    Ali Guner

    2012-01-01

    Full Text Available Retained surgical sponge (RSS is a rare surgical complication. The RSSs are mostly located intra-abdominally but they can also be left in the thorax, spine, extremity, cranium, and breast. RSS is often difficult to diagnose because of the nonspecific clinical symptoms and radiologic findings. Clinically, RSS may present as an exudative reaction in the early postoperative period or may also cause an aseptic fibrous tissue response. A foreign body may remain asymptomatically silent for a long time, and it may later present with obstruction, fistulization, or mass formation. In this report, we present a case in which an RSS has migrated through the abdominal wall and caused an anterior abdominal wall abscess.

  2. Retained Foreign Bodies: A Serious Threat in the Indian Operation ...

    African Journals Online (AJOL)

    Proper communication among the personnel participating in surgery aimed at preventing this medical negligence would help in mitigating such errors. Finally, the surgeon should not only follow the standard recommended procedure, but also report cases of RFBs. Keywords: Medical negligence, Radiography, Retained ...

  3. Complete endoscopic management of a retained bullet in the bladder.

    Science.gov (United States)

    Friedman, Ariella A; Trinh, Quoc-Dien; Kaul, Sanjeev; Bhandari, Akshay

    2013-01-01

    A 25-year-old male gunshot victim presented at our institution with gross hematuria following Foley catheter insertion. Computed tomography and cystogram did not show a bladder perforation, but were notable for a left ischial fracture and the presence of a bullet within the bladder. After failed attempts at retrieving the bullet with a resectoscope and loop, as well as a cystoscope and stone crusher, a 26 French nephroscope was inserted transurethrally, and the bullet was successfully engaged and removed using a Perc NCircle (Cook Medical, Bloomington, IN) grasper. The extra-peritoneal injury was managed conservatively with catheter drainage. To our knowledge, this represents the first case of successful transurethral management of a retained intravesical bullet. Such an approach may benefit patients with retained intravesical bullets or other challenging intravesical foreign bodies and may be helpful in select circumstances to spare patients from more extensive surgeries.

  4. Removal of Retained Lead Shot Through Laparoscopic Appendectomy

    Science.gov (United States)

    Lloyd, D. M.

    2003-01-01

    We describe a patient presenting with lead shot in his appendix. A plain radiograph of his lumbar spine was performed for back pain, and an incidental finding of lead shot retained within the appendix was seen. Lead shot in the appendix is associated with appendicitis, and 2 cases have been reported of lead intoxication. We suggest that an elective laparoscopic appendectomy should be offered to patients as a possible management option. PMID:12856854

  5. An experimental study on oil supply in a space bearing with an oil-impregnated retainer

    Science.gov (United States)

    Liu, Jianhai; Fan, Youwen; Wen, Shizhu

    1993-06-01

    Parched elastohydrodynamic lubrication (EHL) film thickness in a space ball bearing is measured by electrical capacitance and resistance, and parched transients of oil film and lubricant breakdown are observed. With different oil-impregnated polymer retainers, which are employed as oil supply resources, parched degradation is restricted to some degree, even lubricant breakdown disappears and a steady state of the oil film is produced. A long-term space bail bearing demands both the lowest driving torque and a steady state oil film, which depends on a strictly controlled oil supply from oil-impregnated retainers. The results of this experimental research describe the effects of oil supply by amounts of oil in retainers on parched EHL.

  6. The effect of prior tempering on cryogenic treatment to reduce retained austenite

    International Nuclear Information System (INIS)

    Stratton, Paul

    2010-01-01

    The consensus view is that a high carbon case gives gears the best overall properties provided that there is no carbide network and that the retained austenite has been reduced below 20% by cryogenic treatment. This view is effectively enshrined in the SAE AMS 2759/7 standard. The cryogenic treatment usually takes place immediately after the quench to avoid austenite stabilisation. However, for some parts with complex geometries that might crack during the treatment, a short low temperature temper is carried out first. Little is known on how this temper affects the subsequent cryogenic treatment. Three carburizing steels used extensively in the aerospace industry were carburized to produce high retained austenite levels in the case using two different, but typical carburizing cycles. The retained austenite was determined by XRD before and after cryogenic treatment carried out in accordance with the standard and compared with that obtained when an intermediate temper was used. This study shows that for three typical carburizing steels, carburized using typical cycles, the efficacy of the cryogenic treatment is reduced only slightly after the temper, and not enough to be industrially significant. (author)

  7. Assessment of Retained Austenite in AISI D2 Tool Steel Using Magnetic Hysteresis and Barkhausen Noise Parameters

    Science.gov (United States)

    Kahrobaee, Saeed; Kashefi, Mehrdad

    2015-03-01

    Inaccurate heat treatment process could result in excessive amount of retained austenite, which degrades the mechanical properties, like strength, wear resistance, and hardness of cold work tool steel parts. Thus, to control the mechanical properties, quantitative measurement of the retained austenite is a critical step in optimizing the heat-treating parameters. X-ray diffraction method is the most frequently used technique for this purpose. This technique is, however, destructive and time consuming. Furthermore, it is not applicable to 100% quality inspection of industrial parts. In the present paper, the influence of austenitizing temperature on the retained austenite content and hardness of AISI D2 tool steel has been studied. Additionally, nondestructive magnetic hysteresis parameters of the samples including coercivity, magnetic saturation, and maximum differential permeability as well as their magnetic Barkhausen noise features (RMS peak voltage and peak position) have been investigated. The results revealed direct relations between magnetic saturation, differential permeability, and MBN peak amplitude with increasing austenitizing temperature due to the retained austenite formation. Besides, both parameters of coercivity and peak position had an inverse correlation with the retained austenite fraction.

  8. Is magnetic resonance imaging safe for patients with retained metal fragments from combat and terrorist attacks?

    International Nuclear Information System (INIS)

    Eshed, Iris; Kushnir, Tamar; Shabshin, Noga; Konen, Eli

    2010-01-01

    Background: Increasing numbers of military confrontations and terrorist attacks have led to increasing reports of retained metal fragments among patients referred for magnetic resonance imaging (MRI). The potential hazard of retained metal fragments for patients undergoing MRI has been studied among patients with retained metal fragments from domestic violence but not from combat and terrorist attacks. Purpose: To retrospectively evaluate the safety of MRI in patients with subcutaneous warfare-metal fragments. Material and Methods: 10,322 consecutive metal screening forms of patients scheduled for 1.5 Tesla (T) MR examination were retrospectively reviewed. All patients reported to have retained metal fragments were contacted by telephone and asked to describe the event in which they were exposed to the fragments and for any adverse sequelae or sensations during and after MRI. Their radiographs were evaluated for the number and size of the fragments. The data were analyzed for correlations between these factors. Results: Seven of the 24 patients who reported retained metal fragments were excluded, since there was no validating evidence of their presence. Fragments in the remaining 17 patients (18 MRI examinations) were inflicted by military or terrorist attacks that occurred 2-39 years prior to the MRI. The fragment size ranged between 1 and 10 mm. One patient reported a superficial migration of a 10-mm fragment after MRI. No other adverse reactions were reported. Conclusion: Conducting 1.5T MRI examinations is safe in patients with retained metal fragments from combat and terrorist attacks not in the vicinity of vital organs. However, caution is advised.

  9. Is magnetic resonance imaging safe for patients with retained metal fragments from combat and terrorist attacks?

    Energy Technology Data Exchange (ETDEWEB)

    Eshed, Iris; Kushnir, Tamar; Shabshin, Noga; Konen, Eli (Dept. of Diagnostic Imaging, Sheba Medical center, Tel Hashomer, Sackler School of Medicine, Tel Aviv Univ., Tel Aviv (Israel)), e-mail: iris.eshed@sheba.health.gov.il

    2010-03-15

    Background: Increasing numbers of military confrontations and terrorist attacks have led to increasing reports of retained metal fragments among patients referred for magnetic resonance imaging (MRI). The potential hazard of retained metal fragments for patients undergoing MRI has been studied among patients with retained metal fragments from domestic violence but not from combat and terrorist attacks. Purpose: To retrospectively evaluate the safety of MRI in patients with subcutaneous warfare-metal fragments. Material and Methods: 10,322 consecutive metal screening forms of patients scheduled for 1.5 Tesla (T) MR examination were retrospectively reviewed. All patients reported to have retained metal fragments were contacted by telephone and asked to describe the event in which they were exposed to the fragments and for any adverse sequelae or sensations during and after MRI. Their radiographs were evaluated for the number and size of the fragments. The data were analyzed for correlations between these factors. Results: Seven of the 24 patients who reported retained metal fragments were excluded, since there was no validating evidence of their presence. Fragments in the remaining 17 patients (18 MRI examinations) were inflicted by military or terrorist attacks that occurred 2-39 years prior to the MRI. The fragment size ranged between 1 and 10 mm. One patient reported a superficial migration of a 10-mm fragment after MRI. No other adverse reactions were reported. Conclusion: Conducting 1.5T MRI examinations is safe in patients with retained metal fragments from combat and terrorist attacks not in the vicinity of vital organs. However, caution is advised.

  10. [Effect of cigarette smoking on coexistence of cadmium and zinc in retained wisdom teeth].

    Science.gov (United States)

    Malara, Piotr; Kwapuliński, Jerzy; Drugacz, Jan; Malara, Beata

    2005-01-01

    The change in coexistence pattern of elements (antagonism-synergism) in conditions of excessive level of toxic element is observed in many biological samples. The aim of this study was to establish the cadmium and zinc content in hard tissues of retained wisdom teeth of smokers and non-smokers and to find out if active exposure to cigarette smoke has an influence on coexistence of both metals in these tissues. Material consisted of 127 retained wisdom teeth (65 from smokers and 62 from non-smokers). Cadmium and zinc contents were determined by means of atomic absorption spectrometry. We found out that retained wisdom tooth from smokers exhibited higher cadmium and zinc contents compared to non-smokers' teeth. Moreover, coexistence pattern of cadmium and zinc in teeth depends on exposure to heavy metals and exhibits strong synergism in smokers.

  11. Improvement of oral health-related quality-of-life by use of different kinds of double-crown-retained removable partial dentures.

    Science.gov (United States)

    Stober, Thomas; Danner, Daniel; Bömicke, Wolfgang; Hassel, Alexander J

    2016-01-01

    To verify the hypotheses that treatment with double-crown-retained removable partial dentures (RPDs) improves oral health-related quality-of life (OHRQoL) over a 36-month period and that the performance of RPDs retained by use of electroplated double crowns (EP-RPDs) was different to that of RPDs retained by use of cast double crowns (C-RPDs). Fifty-four patients (mean age = 64 years, 63% men) were recruited and randomly assigned to C-RPD or EP-RPD. OHRQoL was assessed pre-treatment, post-treatment and 6, 12, 24 and 36 months after insertion, by use of the oral health impact profile (OHIP). An unweighted total score was calculated (OHIP-SUM). A two-level hierarchical model was used for statistical analysis. First-level units were the measurements on the six occasions; second-level units were the patients. Improvement of OHRQoL was observed in both groups after treatment (t = 7.27, p < 0.001). Whereas a treatment-material interaction indicated that treatment with EP-RPDs resulted in greater immediate improvement of OHRQoL, a time-material interaction indicated that long-term improvement was greater for C-RPDs. Treatment with EP-RPDs and C-RPDs improved OHRQoL initially. Over a period of 36 months the effect was significant. The treatment is, therefore, a promising therapeutic option. The cast conical design seems to have advantages with regard to long-term OHRQoL.

  12. MTBE BIODEGRADATION IN A GRAVITY FLOW, HIGH-BIOMASS RETAINING BIOREACTOR

    Science.gov (United States)

    The aerobic biodegradation of methyl tert-butyl ether (MtBE), a widely used fuel oxygenate, was investigated using a pilot-scale biomass-retaining bioreactor called a Biomass Concentrator Reactor (BCR). The reactor was operated for a year at a flow rate of 2500 L/d on Ci...

  13. 13 CFR 120.1706 - Pool Originator's retained interest in Pool.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Pool Originator's retained interest in Pool. 120.1706 Section 120.1706 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan...

  14. Recruiting & Retaining Women: A Self-Assessment Guide for Law Enforcement.

    Science.gov (United States)

    Harrington, Penny E.

    This document presents information, guidelines, and resource materials to help law enforcement administrators address issues related to recruiting and retaining women in law enforcement. Its 14 chapters contain the following sections: statement of the problem; legal issues; possible solutions, model policies, and practices; expert assistance,…

  15. Intravitreal Phacoemulsification Using Torsional Handpiece for Retained Lens Fragments

    OpenAIRE

    Kumar, Vinod; Takkar, Brijesh

    2016-01-01

    Purpose: To evaluate the results of intravitreal phacoemulsification with torsional hand piece in eyes with posteriorly dislocated lens fragments. Methods: In this prospective, interventional case series, 15 eyes with retained lens fragments following phacoemulsification were included. All patients underwent standard three-port pars plana vitrectomy and intravitreal phacoemulsification using sleeveless, torsional hand piece (OZiL™, Alcon's Infiniti Vision System). Patients were followed up...

  16. Salary is not enough to attract and retain the best

    Directory of Open Access Journals (Sweden)

    Rosa María Fuchs Ángeles

    2015-09-01

    Full Text Available Organizations face the challenge of attracting and retaining talented staff. In some instances, a reference to the existence of a war for talent is made. It is that way that the retention of workers has stopped being managed, exclusively, with the offer of good salaries. This paper explores, in a first instance, the theoretical framework that describes the principal tools of talent retention that companies develop, and that are considered as part of the total remuneration that workers receive: economic compensations, recognition, career plans and staff development, feedback, personal and professional life balance, social network and team making, proper relationship with superiors and organizational climate life. Later, the results that were obtained from interviews with ten of the best companies to work for in Peru, according to the Great Place to Work Institute ranking in 2007, on retaining talent tools that they implement are shown. Finally, conclusions on the case studies are presented.

  17. Telescopic retainers: an old or new solution? A second chance to have normal dental function.

    Science.gov (United States)

    Breitman, Joseph B; Nakamura, Scott; Freedman, Arnold L; Yalisove, Irving L

    2012-01-01

    This article is an overview of the biomechanics and advantages of telescopic retainers. Telescopic retainers offer more possibilities than any other treatment modality available in modern dentistry. Telescopic implant fixtures make the already versatile technique even more flexible. Telescopes should not be forgotten as a treatment modality, but should be embraced as a great option. © 2011 by the American College of Prosthodontists.

  18. Rotational Response of Toe-Restrained Retaining Walls to Earthquake Ground Motions

    National Research Council Canada - National Science Library

    Ebeling, Robert M; White, Barry C

    2006-01-01

    .... The PC software CorpsWallRotate (sometimes referred to as CWRotate) was developed to perform an analysis of permanent wall rotation for each proposed retaining wall section to a user-specified earthquake acceleration time-history...

  19. Design Guidelines for In-Plane Mechanical Properties of SiC Fiber-Reinforced Melt-Infiltrated SiC Composites

    Science.gov (United States)

    Morscher, Gregory N.; Pujar, Vijay V.

    2008-01-01

    In-plane tensile stress-strain, tensile creep, and after-creep retained tensile properties of melt-infiltrated SiC-SiC composites reinforced with different fiber types were evaluated with an emphasis on obtaining simple or first-order microstructural design guidelines for these in-plane mechanical properties. Using the mini-matrix approach to model stress-strain behavior and the results of this study, three basic general design criteria for stress and strain limits are formulated, namely a design stress limit, a design total strain limit, and an after-creep design retained strength limit. It is shown that these criteria can be useful for designing components for high temperature applications.

  20. Veterans Health Administration: Actions Needed to Better Recruit and Retain Clinical and Administrative Staff

    Science.gov (United States)

    2017-03-22

    This Study VHA’s ability to attract, hire, and retain top talent is critical to its mission to provide quality and timely care for our nation’s...States’ military operations in Afghanistan and Iraq and the growing needs of an aging veteran population. Attracting, hiring, and retaining top talent ...police, and housekeepers.7 These employees are covered by three types of personnel systems:8 • Title 5 of the U.S. Code (Title 5): The majority of

  1. City of Hoboken Energy Surety Analysis: Preliminary Design Summary

    Energy Technology Data Exchange (ETDEWEB)

    Stamp, Jason Edwin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Baca, Michael J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Munoz-Ramos, Karina [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Schenkman, Benjamin L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Eddy, John P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Systems Readiness and Sustainment Technology Dept.; Smith, Mark A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Systems Readiness and Sustainment Technology Dept.; Guttromson, Ross [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electric Power Systems Research Dept.; Henry, Jordan M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Critical Infrastructure Systems Dept.; Jensen, Richard Pearson [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Geomechanics Dept.

    2014-09-01

    In 2012, Hurricane Sandy devastated much of the U.S. northeast coastal areas. Among those hardest hit was the small community of Hoboken, New Jersey, located on the banks of the Hudson River across from Manhattan. This report describes a city-wide electrical infrastructure design that uses microgrids and other infrastructure to ensure the city retains functionality should such an event occur in the future. The designs ensure that up to 55 critical buildings will retain power during blackout or flooded conditions and include analysis for microgrid architectures, performance parameters, system control, renewable energy integration, and financial opportunities (while grid connected). The results presented here are not binding and are subject to change based on input from the Hoboken stakeholders, the integrator selected to manage and implement the microgrid, or other subject matter experts during the detailed (final) phase of the design effort.

  2. Recruiting and retaining family caregivers to a randomized controlled trial on mindfulness-based stress reduction.

    Science.gov (United States)

    Whitebird, Robin R; Kreitzer, Mary Jo; Lewis, Beth A; Hanson, Leah R; Crain, A Lauren; Enstad, Chris J; Mehta, Adele

    2011-09-01

    Caregivers for a family member with dementia experience chronic long-term stress that may benefit from new complementary therapies such as mindfulness-based stress reduction. Little is known however, about the challenges of recruiting and retaining family caregivers to research on mind-body based complementary therapies. Our pilot study is the first of its kind to successfully recruit caregivers for a family member with dementia to a randomized controlled pilot study of mindfulness-based stress reduction. The study used an array of recruitment strategies and techniques that were tailored to fit the unique features of our recruitment sources and employed retention strategies that placed high value on establishing early and ongoing communication with potential participants. Innovative recruitment methods including conducting outreach to health plan members and generating press coverage were combined with standard methods of community outreach and paid advertising. We were successful in exceeding our recruitment goal and retained 92% of the study participants at post-intervention (2 months) and 90% at 6 months. Recruitment and retention for family caregiver interventions employing mind-body based complementary therapies can be successful despite many challenges. Barriers include cultural perceptions about the use and benefit of complementary therapies, cultural differences with how the role of family caregiver is perceived, the use of group-based designs requiring significant time commitment by participants, and travel and respite care needs for busy family caregivers. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Improving communication at handover and transfer reduces retained swabs in maternity services.

    Science.gov (United States)

    Lean, Katie; Page, Bethan F; Vincent, Charles

    2018-01-01

    To reduce the incidence of retained vaginal swabs and near misses. A review of previous retained swab incidents and near misses in a large maternity unit identified handovers and transfers as a key point of vulnerability. Interventions were introduced to improve communication at handover from the delivery suite to theatre and from theatre to the high dependency unit. Process data was collected to monitor compliance. The outcome measures were the incidence of retained swab never events and the incidence of near misses. Chi-squared analysis was used to test the significance of the results. For transfers from delivery suite to theatre, verbal handover significantly increased from 28.8% to 75.6% (ptransfers to theatre post-intervention: in 88 (30.2%) of these transfers a vaginal swab was already in situ. In 70/88 (79.5%) of cases the presence of the swab was communicated to theatre staff in three ways (verbally, written and transfer of opened swab packets) according to the new policy. In the post-intervention period there were 56 women transferred from theatre to the high-dependency unit with a vaginal pack in situ: 52 (92.9%) of these women had a sticker in place serving as a constant reminder of the presence of the vaginal pack to staff. Following a baseline of four near misses in two months, there has been only one near miss in the 15 months since the interventions were implemented, (33.3% vs. 1.1%, pcommunication at handover and transfer can reduce the incidence of retained vaginal swabs and near misses. Further work is needed to raise the profile of swab counting in maternity settings: swab counting needs to be the responsibility of all disciplines, not just the responsibility of theatre staff. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Method for reducing power consumption in a state retaining circuit, state reaining circuit and electronic device.

    NARCIS (Netherlands)

    2006-01-01

    A method for reducing the power consumption in a state retaining circuit during a standby mode is disclosed comprising, in an active state, providing a regular power supply (VDD) and a standby power supply (VDD STANDBY) to the state retaining circuit; for a transition from an active state to a

  5. The Interaction Features of the Multi-Level Retaining Walls with Soil Mass

    Science.gov (United States)

    Boyko, Igor; Skochko, Liudmyla; Zhuk, Veronica

    2017-09-01

    The interaction features of multi-level retaining walls with soil base were researched by changing their geometric parameters and locality at the plan. During excavation of deep foundation pits it is important to choose the type of constructions which influences on the horizontal displacements. The distance between the levels of retaining walls should be based on the results of numerical modelling. The objective of this paper is to present a comparison between the data of numerical simulations and the results of the in-situ lateral tests of couple piles. The problems have been solved by using the following soil models: Coulomb-Mohr model; model, which is based on the dilatation theory; elastic-plastic model with variable stiffness parameters.

  6. The effect of prior sandblasting of the wire on the shear bond strength of two different types of lingual retainers.

    Science.gov (United States)

    Kilinç, Delal Dara; Sayar, Gülşilay

    2018-04-07

    The aim of this study was to evaluate the effect of total surface sandblasting on the shear bond strength of two different retainer wires. The null hypothesis was that there is no difference in the bond strength of the two types of lingual retainer wires when they are sandblasted. One hundred and sixty human premolar teeth were equally divided into four groups (n=40). A pair of teeth was embedded in self-curing acrylic resin and polished. Retainer wires were applied on the etched and rinsed surfaces of the teeth. Four retainers were used: group 1: braided retainer (0.010×0.028″, Ortho Technology); group 2: sandblasted braided retainer (0.010×0.028″, Ortho Technology); group 3: coaxial retainer (0.0215″ Coaxial, 3M) and group 4: sandblasted coaxial retainer (0.0215″ Coaxial, 3M). The specimens were tested using a universal test machine in shear mode with a crosshead speed of one mm/min. One-way analysis of variance (Anova) was used to determine the significant differences among the groups. There was no significant difference (P=0.117) among the groups according to this test. The null hypothesis was accepted. There was no statistically significant difference among the shear bond strength values of the four groups. Copyright © 2018 CEO. Published by Elsevier Masson SAS. All rights reserved.

  7. Stability of retained austenite arising at low temperatures in low carbon steels with copper using TRIP effect

    International Nuclear Information System (INIS)

    Michta, G.; Pietrzyk, J.; Osuch, W.; Kruk, A.

    2003-01-01

    The magnetometric measurement results of decomposition of retained austenite arising during low temperature bainite transformation, obtained structure and mechanical properties are presented. Presented results demonstrate that the low temperature bainite transformation leads to formation of two kinds of retained austenite with different stability. Decomposition of low stability retained austenite was observed during cooling to -196 o C, the second with high stability was decomposed only during heating up to 560 o C. The first one was observed in microstructure as big grains and the second more refinement in structure was localised between bainitic regions. (author)

  8. LEO P: HOW MANY METALS CAN A VERY LOW MASS, ISOLATED GALAXY RETAIN?

    Energy Technology Data Exchange (ETDEWEB)

    McQuinn, Kristen B. W.; Skillman, Evan D. [Minnesota Institute for Astrophysics, School of Physics and Astronomy, 116 Church Street, S.E., University of Minnesota, Minneapolis, MN 55455 (United States); Dolphin, Andrew [Raytheon Company, 1151 E. Hermans Road, Tucson, AZ 85756 (United States); Cannon, John M. [Department of Physics and Astronomy, Macalester College, 1600 Grand Avenue, Saint Paul, MN 55105 (United States); Salzer, John J.; Rhode, Katherine L. [Department of Astronomy, Indiana University, 727 East 3rd Street, Bloomington, IN 47405 (United States); Adams, Elizabeth A. K. [ASTRON, the Netherlands Institute for Radio Astronomy, Postbus 2, 7990 AA, Dwingeloo (Netherlands); Berg, Danielle [Center for Gravitation, Cosmology and Astrophysics, Department of Physics, University of Wisconsin Milwaukee, 1900 East Kenwood Boulevard, Milwaukee, WI 53211 (United States); Giovanelli, Riccardo; Haynes, Martha P., E-mail: kmcquinn@astro.as.utexas.edu [Center for Radiophysics and Space Research, Space Sciences Building, Cornell University, Ithaca, NY 14853 (United States)

    2015-12-20

    Leo P is a gas-rich dwarf galaxy with an extremely low gas-phase oxygen abundance (3% solar). The isolated nature of Leo P enables a quantitative measurement of metals lost solely due to star formation feedback. We present an inventory of the oxygen atoms in Leo P based on the gas-phase oxygen abundance measurement, the star formation history (SFH), and the chemical enrichment evolution derived from resolved stellar populations. The SFH also provides the total amount of oxygen produced. Overall, Leo P has retained 5% of its oxygen; 25% of the retained oxygen is in the stars while 75% is in the gas phase. This is considerably lower than the 20%–25% calculated for massive galaxies, supporting the trend for less efficient metal retention for lower-mass galaxies. The retention fraction is higher than that calculated for other alpha elements (Mg, Si, Ca) in dSph Milky Way satellites of similar stellar mass and metallicity. Accounting only for the oxygen retained in stars, our results are consistent with those derived for the alpha elements in dSph galaxies. Thus, under the assumption that the dSph galaxies lost the bulk of their gas mass through an environmental process such as tidal stripping, the estimates of retained metal fractions represent underestimates by roughly a factor of four. Because of its isolation, Leo P provides an important datum for the fraction of metals lost as a function of galaxy mass due to star formation.

  9. Good Laboratory Practice. Part 2. Recording and Retaining Raw Data

    Science.gov (United States)

    Wedlich, Richard C.; Libera, Agata E.; Pires, Amanda; Tellarini, Cassandra

    2013-01-01

    A clear understanding of how "raw data" is defined, recorded, and retained in the laboratory record is essential to the chemist employed in the laboratory compliant with the Good Laboratory Practices regulations. This article is intended to provide an understanding by drawing upon examples taken from the modern pharmaceutical analysis…

  10. Survival of various implant-supported prosthesis designs following 36 months of clinical function.

    Science.gov (United States)

    Rodriguez, A M; Orenstein, I H; Morris, H F; Ochi, S

    2000-12-01

    The use of endosseous dental implants to replace natural teeth lost to trauma, dental caries, or periodontal disease has become a predictable form of prosthetic treatment since gaining popularity in the early 1980s. While numerous clinical studies have focused on the survival of implants, few address the survival of different prosthesis designs. Beginning in 1991, 882 prostheses supported by more than 2,900 implants (687 patients) were placed by the Department of Veterans Affairs Dental Implant Clinical Research Group (DICRG). These prostheses were divided into five research strata based on arch location. The recommended design for each stratum was: bar-supported overdenture (maxillary completely edentulous); screw-retained hybrid denture (mandibular completely edentulous); screw-retained fixed partial denture (mandibular and maxillary posterior partially edentulous); and cemented single crown (maxillary anterior single tooth). Alternative overdenture designs were utilized in the edentulous arches when the recommended prosthesis could not be fabricated. Prosthesis success rates for the research strata were calculated for an observation time of up to 36 months following prosthesis placement. Success rates for the maxillary edentulous stratum ranged from 94.6% for the bar-retained overdenture supported by five to six fixtures to 81.8% for the cap-retained overdenture. The mandibular edentulous strata produced success rates of 98.1% for the fixed hybrid prosthesis to 91.7% for the cap-retained prosthesis. Success rates for maxillary and mandibular posterior fixed partial dentures were 94.3% and 92.6%, respectively, while the maxillary anterior single-tooth prosthesis yielded a success rate of 98.1% for the 36-month observation period. The recommended prosthesis designs investigated in this study proved to be reliable, with encouraging success rates for an observation period of 36 months following placement.

  11. What is required to retain registered nurses in the public health ...

    African Journals Online (AJOL)

    What is required to retain registered nurses in the public health sector in Malawi? ... public sector in search for better remuneration in the private sector including ... The results indicate that poor salaries, heavy workloads, lack of promotional ...

  12. The applicability of nanofiltration for the treatment and reuse of ...

    African Journals Online (AJOL)

    The main aim of the study was to test the feasibility of using nanofiltration (NF) processes for the treatment of reactive dyebath effluents from the textile industry, in order to recover the water and chemicals (salts) for reuse purposes. The study of the reusability of nanofiltered water for dyeing has been given little or no ...

  13. Nuclear fuel element nut retainer cup

    International Nuclear Information System (INIS)

    Walton, L.A.

    1977-01-01

    A typical embodiment has an end fitting for a nuclear reactor fuel element that is joined to the control rod guide tubes by means of a nut plate assembly. The nut plate assembly has an array of nuts, each engaging the respective threaded end of the control rod guide tubes. The nuts, moreover, are retained on the plate during handling and before fuel element assembly by means of hollow cylindrical locking cups that are brazed to the plate and loosely circumscribe the individual enclosed nuts. After the nuts are threaded onto the respective guide tube ends, the locking cups are partially deformed to prevent one or more of the nuts from working loose during reactor operation. The locking cups also prevent loose or broken end fitting parts from becoming entrained in the reactor coolant

  14. An orthodontic device for retaining implanted radioactive sources during brachytherapy for cancer of the oral cavity

    International Nuclear Information System (INIS)

    Masuko, Noriko; Katsura, Kouji; Sugita, Tadashi; Sakai, Kunio; Sato, Katsurou; Kawana, Masahiro; Nonomura, Naobumi

    2000-01-01

    An orthodontic retainer was devised to keeping implanted radioactive sources in position and improve the quality of life during brachytherapy for cancer of the oral cavity. The retainer was used in 3 patients with oral cancer, one with cancer of the hard palate, one with cancer of the soft palate, and one with cancer of the floor of mouth, during brachytherapy using 198 Au grains and 137 Cs needles. These patients could speak freely. One with cancer of the hard palate could drink water and ingest semi-liquid food during treatment instead of nasal tube feeding. The plaster dental model obtained while making the retainer proved to be useful for training radiation oncologists. (author)

  15. RETAINED STONE PIECE IN ANTERIOR CHAMBER

    Directory of Open Access Journals (Sweden)

    ZvornicaninJasmin, Nadarevic-VodencarevicAmra

    2015-04-01

    Full Text Available ABSTRACT We read with interest the article by Surekha et al. regarding the retained stone piece in anterior chamber. Similar to the results of previous studies, the authors found that delayed intraocular foreign body (IOFB management can result in good visual outcome without an apparent increased risk of endophthalmitis or other deleterious side effects. However, the authors failed to explain the exact reason for the diminution of vision in patients left eye. It is unclear what the uncorrected visual acuity was and what kind of correction was used, more precisely type and amount of cylinder, given the presence of the corneal opacity. Since the size of the IOFB is approximately 4x4x1mm, significant irido-corneal angle changes resulting in intraocular pressure raise and optic nerve head damage can be expected. Traumatic glaucoma following open globe injury can occur in 2.7 to 19% of cases, with several risk factors associated with glaucoma development (advanced age, poor visual acuity at presentation,perforating rather than penetrating ocular injury,lens injury, presence of vitreous hemorrhage and presence of an IOFB. Earlier reportsof latetraumaticoptic neuropathy onset, even after several years, indicate that this possibility cannot be completely ruled out too. Therefore, repeated intraocular pressure measurements, gonioscopy, pupillary reaction assessment, together with through posterior segment examination including visual field and optical coherence tomography examinations can be useful in determining the possible optic nerve damage as one of the possible reasons for visual acuity reduction. The authors did not suggest any operative treatment at this time. However, it should bear in mind that the inert anterior chamber IOFB could be a risk factor for non-infectious endophthalmitis development even after many years. Also, long term retained anterior chamber foreign body leads to permanent endothelial cell loss and can even result in a corneal

  16. Single dental implant retained mandibular complete dentures – influence of the loading protocol: study protocol for a randomized controlled trial

    Science.gov (United States)

    2014-01-01

    Background Over the years, there has been a strong consensus in dentistry that at least two implants are required to retain a complete mandibular denture. It has been shown in several clinical trials that one single median implant can retain a mandibular overdenture sufficiently well for up to 5 years without implant failures, when delayed loading was used. However, other trials have reported conflicting results with in part considerable failure rates when immediate loading was applied. Therefore it is the purpose of the current randomized clinical trial to test the hypothesis that immediate loading of a single mandibular midline implant with an overdenture will result in a comparable clinical outcome as using the standard protocol of delayed loading. Methods/design This prospective nine-center randomized controlled clinical trial is still ongoing. The final patient will complete the trial in 2016. In total, 180 edentulous patients between 60 and 89 years with sufficient complete dentures will receive one median implant in the edentulous mandible, which will retain the existing complete denture using a ball attachment. Loading of the median implant is either immediately after implant placement (experimental group) or delayed by 3 months of submerged healing at second-stage surgery (control group). Follow-up of patients will be performed for 24 months after implant loading. The primary outcome measure is non-inferiority of implant success rate of the experimental group compared to the control group. The secondary outcome measures encompass clinical, technical and subjective variables. The study was funded by the Deutsche Forschungsgemeinschaft (German research foundation, KE 477/8-1). Discussion This multi-center clinical trial will give information on the ability of a single median implant to retain a complete mandibular denture when immediately loaded. If viable, this treatment option will strongly improve everyday dental practice. Trial registration The trial

  17. Comparação de parâmetros periodontais após utilização de contenção ortodôntica com fio trançado e contenção modificada Comparison of periodontal parameters after the use of orthodontic multi-stranded wire retainers and modified retainers

    Directory of Open Access Journals (Sweden)

    Marlice Azoia Lukiantchuki

    2011-08-01

    Full Text Available OBJETIVO: o presente estudo teve como objetivo comparar dois tipos de contenções ortodônticas fixas, em relação a parâmetros periodontais estabelecidos. A contenção com fio trançado é a mais comumente utilizada e a contenção modificada apresenta dobras que têm a finalidade de permitir o livre acesso do fio dental às áreas interproximais. MÉTODOS: para esse estudo cruzado, foram selecionados 12 voluntários que utilizaram, por 6 meses, A Contenção com fio trançado e B Contenção modificada - sendo essas fixadas em todos os dentes do segmento anterior. Após esse período experimental, foram feitas as seguintes avaliações: Índice de Placa Dentária, Índice Gengival, Índice de Cálculo Dentário e Índice de Cálculo ao longo do fio de contenção. Os voluntários também responderam a um questionário com relação à utilização, conforto e higienização das contenções. RESULTADOS: foi observado que o índice de placa e o índice gengival foram maiores nas faces linguais (pOBJECTIVE: The objective of the present study was to compare two types of fixed orthodontic retainers (a multi-stranded wire retainer and a modified retainer in relation to established periodontal parameters. The multi-stranded wire retainer is commonly used, and the modified retainer has bends to enable free access of dental floss to interproximal areas. METHODS: For this crossover study, 12 volunteers were selected and used the following retainers for six months: (A a multi-stranded wire retainer and (B a modified retainer. Both retainers were fixed to all anterior lower teeth.After this experimental period, the following evaluations were made: Dental Plaque Index, Gingival Index, Dental Calculus Index and Retainer Wire Calculus Index. The volunteers also responded to a questionnaire about the use, comfort and hygiene of the retainers. RESULTS: It was observed that the plaque index and the gingival index were higher on the lingual surface (p<0

  18. Evaluation of bond strength and load deflection rate of multi-stranded fixed retainer wires: An In-Vitro Study

    Directory of Open Access Journals (Sweden)

    Renu Sarah Samson

    2018-01-01

    Full Text Available Background: Fixed orthodontic retainers must be well retained on the tooth surfaces, allow physiologic movement of teeth and exert minimal forces on the teeth to be retained. Previous studies analyzed the bond strength and amount of deflection caused due to the debonding force but not the magnitude of force needed for unit deformation. Aims: This study aims to evaluate and compare the bond strength and load deflection rate (LDR of three different fixed retainer wires. Materials and Methods: The wires were divided into three Groups: A – three-stranded twisted ligature wire, B – Bond-A-Braid (Reliance Orthodontics, and C – three-stranded twisted lingual retainer wire (3M Unitek. Twenty models were prepared for each group with a passive 15 mm long lingual retainer wire bonded to two lower incisors. An occlusogingival force was applied to the wire until it debonded. For LDR, three-point bending test was done at 0.5 mm deflection. These forces were measured using a Universal Instron Testing Machine. Statistical Analysis: Mean bond strength/LDR and pairwise comparisons were analyzed with one-way ANOVA and Tukey's honest significant difference post hoc test, respectively. Results: Group C exhibited the highest mean bond strength and LDR of 101.17N and 1.84N, respectively. The intergroup comparisons were all statistically significant. Conclusion: Compared to the other two wire types, Group C might be better retained on the teeth due to its higher bond strength. With its relatively higher LDR value, it may resist deformation from occlusal forces, thereby reducing inadvertent tooth movement and yet remain flexible enough to allow physiologic tooth movements.

  19. The Interaction Features of the Multi-Level Retaining Walls with Soil Mass

    Directory of Open Access Journals (Sweden)

    Boyko Igor

    2017-09-01

    Full Text Available The interaction features of multi-level retaining walls with soil base were researched by changing their geometric parameters and locality at the plan. During excavation of deep foundation pits it is important to choose the type of constructions which influences on the horizontal displacements. The distance between the levels of retaining walls should be based on the results of numerical modelling. The objective of this paper is to present a comparison between the data of numerical simulations and the results of the in-situ lateral tests of couple piles. The problems have been solved by using the following soil models: Coulomb-Mohr model; model, which is based on the dilatation theory; elastic-plastic model with variable stiffness parameters.

  20. The cyclops lesion after bicruciate-retaining total knee replacement

    OpenAIRE

    Klaassen, Mark A.; Aikins, Jerry L.

    2017-01-01

    The cyclops lesion is a localized anterior arthrofibrosis most commonly seen following anterior cruciate ligament reconstruction. The lesion forms at the anterior cruciate ligament insertion creating a painful extension block between femoral intercondylar notch and tibial plateau. We present 2 cases (3 knees) in which cyclops lesions appeared atypically following bicruciate-retaining total knee replacement. Two lesions occurred in a single patient following bilateral knee replacement. One les...

  1. A study of the carbon distribution in retained austenite

    International Nuclear Information System (INIS)

    Scott, C.P.; Drillet, J.

    2007-01-01

    Cold-rolled and annealed transformation-induced plasticity (TRIP) steels were overaged to modify the carbon concentrations (C γ ) in retained austenite. Experimental C γ values were directly obtained by electron energy loss spectroscopy and compared with data derived from X-ray diffraction measurements of the austenite lattice parameter (a γ ). In this way, we evaluated the different expressions available in the literature relating C γ to a γ

  2. Quantitative analysis of retained austenite in laser melted martensitic stainless steel

    CSIR Research Space (South Africa)

    Seleka, T

    2007-11-01

    Full Text Available of this study was to determine if X-ray diffraction (XRD) was sufficient for quantifying the volume percentage of retained austenite. After a preliminary qualitative analysis, a Rietveld full pattern refinement program was used to quantify the volume percentage...

  3. Swallowing thresholds of mandibular implant-retained overdentures with variable portion sizes

    NARCIS (Netherlands)

    Fontijn-Tekamp, F.A.; Slagter, A.P.; Van der Bilt, A.; Van't Hof, M.A.; Kalk, W.; Jansen, J.A.

    2004-01-01

    We analysed the effect of three portion sizes Optocal Plus (small, medium and large) on swallowing thresholds in subjects with either conventional complete dentures or mandibular implant-retained overdentures (transmandibular and permucosal cylindric implants). Tests were carried out in 52 women and

  4. Reliability and mechanical design

    International Nuclear Information System (INIS)

    Lemaire, Maurice

    1997-01-01

    A lot of results in mechanical design are obtained from a modelisation of physical reality and from a numerical solution which would lead to the evaluation of needs and resources. The goal of the reliability analysis is to evaluate the confidence which it is possible to grant to the chosen design through the calculation of a probability of failure linked to the retained scenario. Two types of analysis are proposed: the sensitivity analysis and the reliability analysis. Approximate methods are applicable to problems related to reliability, availability, maintainability and safety (RAMS)

  5. Effect of heat treatment on surface hydrophilicity-retaining ability of titanium dioxide nanotubes

    Science.gov (United States)

    Sun, Yu; Sun, Shupei; Liao, Xiaoming; Wen, Jiang; Yin, Guangfu; Pu, Ximing; Yao, Yadong; Huang, Zhongbing

    2018-05-01

    The aim of this study is to investigate the effect of different annealing temperature and atmosphere on the surface wettability retaining properties of titania nanotubes (TNs) fabricated by anodization. The TNs morphology, crystal phase composition and surface elemental composition and water contact angle (WCA) were investigated by scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy and contact angle instrument, respectively. After the samples annealed at 200 °C, 450 °C, 850 °C have been stored in air for 28 days, the WCAs increase to 31.7°, 21.1° and 110.5°, respectively. The results indicate that crystal phase composition of TNs plays an important role in surface wettability. Compared with the WCA (21.1°) of the samples annealed in air after 28 days, the WCA of samples annealed in oxygen-deficient atmosphere is lower, suggesting the contribution of oxygen vacancy in the enhanced hydrophilicity-retaining ability. Our study demonstrates that the surface hydrophilicity-retaining ability of TNs is related to the ordered nanotubular structure, crystal structure, the amount of surface hydroxyl group and oxygen vacancy defects.

  6. Masticatory efficiency and oral health-related quality of life with implant-retained mandibular overdentures

    Science.gov (United States)

    Sun, Xu; Zhai, Jun-Jiang; Liao, Jian; Teng, Min-Hua; Tian, Ai; Liang, Xing

    2014-01-01

    Objectives: To evaluate masticatory efficiency (ME) and oral health-related quality of life (OHRQoL) in patients rehabilitated with implant-retained mandibular overdentures. Methods: In this randomized controlled clinical trial, 50 edentulous patients visiting the Implant Center and Department of Prosthodontics, West China College of Stomatology, Sichuan University, Chengdu, China between June 2010 and June 2012 were selected and received 2 implant-retained mandibular overdenture treatments. All patients were rehabilitated with maxillary complete dentures. The ME and OHRQoL were determined both one month before the mandibular complete denture was anchored to the osseointegrated implants, and 6 months after anchoring. Paired t-tests were used to compare means of ME, and oral health impact profile-49 (OHIP-49) domains scores between pre- and post-implant. Linear regression models were utilized to seek correlations between ME and OHIP domains scores. Results: The ME increased from pre- to post-implant retained mandibular overdentures significantly (p<0.001). The total OHIP score and 4 subscales scores were changed significantly from pre- to post-implant; namely, functional limitation, psychological discomfort, physical disability, and physical pain. The total OHIP score, functional limitation, physical disability, and physical pain subscale scores were related to ME. Conclusion: Implant-retained mandibular over dentures can significantly improve patients’ ME and OHRQoL. The improvement in OHRQoL is mainly because of the improved ME. An improved chewing experience, and pain relief also contributes to improvement of OHRQoL. PMID:25316463

  7. Balancing trust and power: a qualitative study of GPs perceptions and strategies for retaining patients in preventive health checks.

    Science.gov (United States)

    Broholm-Jørgensen, Marie; Guassora, Ann Dorrit; Reventlow, Susanne; Dalton, Susanne Oksbjerg; Tjørnhøj-Thomsen, Tine

    2017-03-01

    Little is known about how strategies of retaining patients are acted out by general practitioners (GPs) in the clinical encounter. With this study, we apply Grimens' (2009) analytical connection between trust and power to explore how trust and power appear in preventive health checks from the GPs' perspectives, and in what way trust and power affect and/or challenge strategies towards retaining patients without formal education. Data in this study were obtained through semi-structured interviews with GPs participating in an intervention project, as well as observations of clinical encounters. From the empirical data, we identified three dimensions of respect: respect for the patient's autonomy, respect for professional authority and respect as a mutual exchange. A balance of respect influenced trust in the relationship between GP and patients and the transfer of power in the encounter. The GPs articulated that a balance was needed in preventive health checks in order to establish trust and thus retain the patient in the clinic. One way this balance of respect was carried out was with the use of humour. To retain patients without formal education in the clinical encounter, the GPs balanced trust and power executed through three dimensions of respect. In this study, retaining patients was equivalent to maintaining a trusting relationship. A strategic use of the three dimensions of respect was applied to balance trust and power and thus build or maintain a trusting relationship with patients. KEY POINTS   Little is known about how strategies for retaining patients are acted out by GPs in preventive health checks.  •  Retaining patients requires a balance of trust and power, which is executed through three dimensions of respect by the GPs.  •  Challenges of recruiting and retaining patients in public health initiatives might be associated with the balance of respect.

  8. A simple procedure for retrieval of a cement-retained implant-supported crown: a case report.

    Science.gov (United States)

    Buzayan, Muaiyed Mahmoud; Mahmood, Wan Adida; Yunus, Norsiah Binti

    2014-02-01

    Retrieval of cement-retained implant prostheses can be more demanding than retrieval of screw-retained prostheses. This case report describes a simple and predictable procedure to locate the abutment screw access openings of cementretained implant-supported crowns in cases of fractured ceramic veneer. A conventional periapical radiography image was captured using a digital camera, transferred to a computer, and manipulated using Microsoft Word document software to estimate the location of the abutment screw access.

  9. USING BRANDING TO ATTRACT, RECRUIT, AND RETAIN TALENTED STAFF

    Directory of Open Access Journals (Sweden)

    Nicoleta Valentina FLOREA

    2011-01-01

    Full Text Available In this environment in continuous changing it is hard for organizations toattract and maintain the best candidates. The organizations use manymethods to recruit and hire, but now it is time to use the organization’s brandto attract talents the organization would like. This article will define theemployer brand as the organization’s image, as an exceptional place to workin the minds of the current employees as well as potential candidates, clients,customers, and stakeholders. The case study is made in six largeorganizations from Dambovita County, Romania, and describes how to usethe organization’s brand to attract, retain, and engage the people it needs. Imade a survey and the data collected I putted them in a model of analyzeand can be applied to any organization which wants to find out if it is usingcorrectly its strong powers to attract and retain the best candidates. Theemployer brand is the value proposition that organization conveys itsemployees and the external labor market. Great organizations create such astrong brand that it draws the talent to them rather than having to spendsignificant time and money on selling the organization to the talent market.Many benefits in the recruiting world are provided by a strong employmentbrand.

  10. Influence of Acidification on the Partitioning of Steroid Hormones among Filtrate, Filter Media, and Retained Particulate Matter.

    Science.gov (United States)

    Havens, Sonya M; Hedman, Curtis J; Hemming, Jocelyn D C; Mieritz, Mark G; Shafer, Martin M; Schauer, James J

    2016-09-01

    Hormone contamination of aquatic systems has been shown to have deleterious effects on aquatic biota. However, the assessment of hormone contamination of aquatic environments requires a quantitative evaluation of the potential effects of sample preservation on hormone concentrations. This study investigated the influence of acidification (pH 2) of surface water samples on the partitioning of hormones among filtrate, filter media, and filter-retained particulate matter. Hormones were spiked into unpreserved and sulfuric acid-preserved ultrapure water and surface water runoff samples. The samples were filtered, and hormones were extracted from the filter and filtrate and analyzed by high-performance liquid chromatography. Acidification did not influence the partitioning of hormones onto the filter media. For the majority of the hormones investigated in this study, the partitioning of hormones to the filter-retained particulate matter was not influenced by acidification. Acidification increased the partitioning of progesterone and melengestrol acetate onto the retained particulate matter (about 25% for both analytes). Incorporation of an isotopically labeled internal standard (ISTD) for progesterone accounted for the loss of progesterone to the filter-retained particulates and resulted in accurate concentrations of progesterone in the filtrate. The incorporation of an ISTD for melengestrol acetate, however, was unable to account for the loss of melengestrol acetate to the retained particulates and resulted in underestimations of melengestrol acetate in the filtrate. Our results indicate that the analysis of melengestrol acetate in acid preserved surface runoff samples should be conducted on the filter-retained particulates as well as the filtrate. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  11. Accuracy of fit of 3-to-3 retainers after adhesive fixation using a neodymium-iron-boron magnet chain.

    Science.gov (United States)

    Hahn, Wolfram; Wasser-Merkel, Wiebke; Lange, Katharina; Gruber, Rudolf M; Kubein-Meesenburg, Dietmar; Ihlow, Dankmar

    2011-10-01

    Six-base retainers are often used to prevent tertiary crowding. To minimize shear stress on the retainer, these should be fitted as precisely as possible. The aim of this study was to compare the accuracy of fit of 6-base retainers after adhesive fixation using a neodymium-iron-boron (NdFeB) magnet chain or a resin positioning aid. A 6-base retainer was prepared for 40 pseudo-anonymous lower jaw models (2 × 20). Temporary fixation was performed with a resin positioning aid or a NdFeB magnet chain. The adhesive fixation of the retainers was randomized. The area and vertical distance between wire and teeth were determined by histomorphometry. The results were evaluated by ANOVA. The probability of error was specified as 5%. With the magnetic chain method, the area was significantly smaller than with the positioning aid (p = 0.0125). The difference between the two methods was ca. 1.3 mm². Moreover, the measured distance was affected significantly by the method used (p NdFeB magnet chain is used even though the wire is not as precisely positioned as it would be with a custom-made positioning aid.

  12. Two dimensional fall of granular columns controlled by slow horizontal withdrawal of a retaining wall

    Science.gov (United States)

    Mériaux, Catherine

    2006-09-01

    This paper describes a series of experiments designed to investigate the fall of granular columns in a quasi-static regime. Columns made of alternatively green and red sand layers were initially laid out in a box and then released when a retaining wall was set in slow motion with constant speed. The dependence of the dynamics of the fall on the initial aspect ratio of the columns, the velocity of the wall, and the material properties was investigated within the quasi-static regime. A change in the behavior of the columns was identified to be a function of the aspect ratio (height/length) of the initial sand column. Columns of high aspect ratio first subsided before sliding along failure planes, while columns of small aspect ratio were only observed to slide along failure planes. The transition between these two characteristic falls occurred regardless of the material and the velocity of the wall in the context of the quasi-static regime. When the final height and length of the piles were analyzed, we found power-law relations of the ratio of initial to final height and final run-out to initial length with the aspect ratio of the column. The dissipation of energy is also shown to increase with the run-out length of the pile until it reaches a plateau. Finally, we find that the structure of the slip planes that develop in our experiments are not well described by the failure of Coulomb's wedges for twin retaining rough walls.

  13. Anticandida Activity Is Retained in P-113, a 12-Amino-Acid Fragment of Histatin 5

    OpenAIRE

    Rothstein, David M.; Spacciapoli, Peter; Tran, Linh T.; Xu, Tao; Roberts, F. Donald; Dalla Serra, Mauro; Buxton, Deborah K.; Oppenheim, Frank G.; Friden, Phillip

    2001-01-01

    Through the analysis of a series of 25 peptides composed of various portions of the histatin 5 sequence, we have identified P-113, a 12-amino-acid fragment of histatin 5, as the smallest fragment that retains anticandidal activity comparable to that of the parent compound. Amidation of the P-113 C terminus increased the anticandidal activity of P-113 approximately twofold. The three histidine residues could be exchanged for three hydrophobic residues, with the fragment retaining anticandidal ...

  14. Baseline estimate of the retained gas volume in Tank 241-C-106

    International Nuclear Information System (INIS)

    Stewart, C.W.; Chen, G.

    1998-06-01

    This report presents the results of a study of the retained gas volume in Hanford Tank 241-C-106 (C-106) using the barometric pressure effect method. This estimate is required to establish the baseline conditions for sluicing the waste from C-106 into AY-102, scheduled to begin in the fall of 1998. The barometric pressure effect model is described, and the data reduction and detrending techniques are detailed. Based on the response of the waste level to the larger barometric pressure swings that occurred between October 27, 1997, and March 4, 1998, the best estimate and conservative (99% confidence) retained gas volumes in C-106 are 24 scm (840 scf) and 50 scm (1,770 scf), respectively. This is equivalent to average void fractions of 0.025 and 0.053, respectively

  15. [Knowledge retain of BLS and BLS-D theoretical contents in a long-term follow-up].

    Science.gov (United States)

    Paolini, Enrico; Conti, Elettra; Guerra, Federico; Capucci, Alessandro

    2018-03-01

    Despite the many recent improvements in basic life support (BLS) and the widespread training to a great number of lay rescuers, out-of-hospital cardiac arrest (OHCA) is still a major cause of death. Nowadays, BLS teaching protocols ask for many concepts to be learned and specific algorithms to be applied, without any available data on how much all these inputs are retained by the students. The present survey aims to evaluate how BLS is really retained by those rescuers (laypersons and nurses) who do not often put it into practice. The first survey was targeted at laypersons who are responsible for security in their work environment. The second survey was targeted at nurses operating in low-intensity wards or out-of-hospital clinics. Both surveys were anonymous and asked specific questions aimed at evaluating how BLS/BLS-D (BLS and defibrillation) information was retained on an average of 3 years after training completion. Lay rescuers showed difficulties in recognizing specific signs of OHCA, were unsure on when to call the emergency medical service and retained few and sometime erroneous information on the correct BLS sequence to perform. The nurses operating in low-intensity settings performed better in terms of OHCA recognition and advanced medical assistance activation, while how to set and operate an automatic external defibrillation was seldom clear. BLS information is usually not retained after a 3-year follow-up by people who are not involved in OHCA management as part of their everyday job. It should be useful to lower the number of concepts taught in current BLS courses in order to focus on the most significant aspects of it, such as prompt emergency medical system activation and early defibrillation.

  16. Excellent solar energy absorbing and retaining fabric material. Chikunetsu hoon sen'i sozai

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, T. (Unitika Ltd., Osaka (Japan). Central Research Lab.)

    1993-11-10

    Carbides of group IV transition metals such as ZrC, which are used as solar energy selective absorption film for solar energy collectors, has characteristics of absorbing light with a high energy of 0.6eV or more and of converting it to heat when exposed to light, and of not absorbing but reflecting light with a low energy of less than 0.6eV. By using ZrC as fabric materials, therefore, portable and durable heat absorbing and retaining materials can be produced. The authors have developed a solar energy absorbing and retaining fabric material, 'Solar [alpha]' (registered trade mark), which absorbs visible and near infrared rays and converts them to heat, and reflects heat from a human body and confines it. The use of Solar [alpha] has been found in various fields such as clothing as a new material for winter-sportswear, slacks, coats, and swimming suits. In this report, the heat absorbing and retaining mechanisms, basic properties of Solar [alpha], and the results of wearing tests are described. 12 refs., 6 figs., 3 tabs.

  17. Systematic design of slow-light photonic waveguides

    DEFF Research Database (Denmark)

    Matzen, René; Jensen, Jakob Søndergaard; Sigmund, Ole

    2011-01-01

    between the access ridge and the W1 PhC waveguide. To retain periodicity and symmetry, the active design set is limited to the in-/outlet region and a distributed supercell, and manufacturability is further enhanced by density filtering techniques combined with material phase projections....

  18. Review of the Nomenclature of the Retaining Ligaments of the Cheek: Frequently Confused Terminology

    Directory of Open Access Journals (Sweden)

    Yeui Seok Seo

    2017-07-01

    Full Text Available Since the time of its inception within facial anatomy, wide variability in the terminology as well as the location and extent of retaining ligaments has resulted in confusion over nomenclature. Confusion over nomenclature also arises with regard to the subcutaneous ligamentous attachments, and in the anatomic location and extent described, particularly for zygomatic and masseteric ligaments. Certain historical terms—McGregor’s patch, the platysma auricular ligament, parotid cutaneous ligament, platysma auricular fascia, temporoparotid fasica (Lore’s fascia, anterior platysma-cutaneous ligament, and platysma cutaneous ligament—delineate retaining ligaments of related anatomic structures that have been conceptualized in various ways. Confusion around the masseteric cutaneous ligaments arises from inconsistencies in their reported locations in the literature because the size and location of the parotid gland varies so much, and this affects the relationship between the parotid gland and the fascia of the masseter muscle. For the zygomatic ligaments, there is disagreement over how far they extend, with descriptions varying over whether they extend medially beyond the zygomaticus minor muscle. Even the ‘main’ zygomatic ligament’s denotation may vary depending on which subcutaneous plane is used as a reference for naming it. Recent popularity in procedures using threads or injectables has required not only an accurate understanding of the nomenclature of retaining ligaments, but also of their location and extent. The authors have here summarized each retaining ligament with a survey of the different nomenclature that has been introduced by different authors within the most commonly cited published papers.

  19. Comparison of Wear Resistance of Hawley and Vacuum Formed Retainers: An in-vitro Study

    Directory of Open Access Journals (Sweden)

    Moshkelgosha V

    2016-06-01

    Full Text Available Statement of Problem: As a physical property, wear resistance of the materials used in the fabrication of orthodontic retainers play a significant role in the stability and long term use of the appliances. Objectives: To evaluate the wear resistance of two commonly used materials for orthodontic retainers: Acropars OP, i.e. a polymethyl methacrylate based material, and 3A-GS060, i.e. a polyethylene based material. Materials and Methods: For each material, 30 orthodontic retainers were made according to the manufacturers’ instructions and a 30×30×2 mm block was cut out from the mid- palatal area of each retainer. Each specimen underwent 1000 cycles of wear stimulation in a pin on disc machine. The depth of wear of each specimen was measured using a Nano Wizard II atomic force microscope in 3 random points of each specimen’s wear trough. The average of these three measurements was calculated and considered as mean value wear depth of each specimen (µm. Results: The mean wear depth was 6.10µm and 2.15µm for 3A-GS060 and Acropars OP groups respectively. Independent t-test showed a significant difference between the two groups (p < 0.001. The results show Polymethyl methacrylate base (Acropars is more wear resistance than the polyethylene based material (3A-GS060. Conclusions: As the higher wear resistance of the fabrication material can improve the retainers’ survival time and its cost-effectiveness, VFRs should be avoided in situations that the appliance needs high wear resistance such as bite blocks opposing occlusal forces.

  20. The stability of gabion walls for earth retaining structures

    OpenAIRE

    Mahyuddin Ramli; T.J.r. Karasu; Eethar Thanon Dawood

    2013-01-01

    The stability of earth retaining structures in flood prone areas has become a serious problem in many countries. The two most basic causes of failure arising from flooding are scouring and erosion of the foundation of the superstructure. Hence, a number of structures like bridges employ scour-arresting devices, e.g., gabions to acting on the piers and abutments during flooding. Research was therefore undertaken to improve gabion resistance against lateral movement by means of an interlocking ...

  1. 9 CFR 355.23 - Tagging products “U.S. retained.”

    Science.gov (United States)

    2010-01-01

    ... INSPECTION AND CERTIFICATION CERTIFIED PRODUCTS FOR DOGS, CATS, AND OTHER CARNIVORA; INSPECTION... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Tagging products âU.S. retained.â 355.23 Section 355.23 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF...

  2. Kinetics modeling of delta-ferrite formation and retainment during casting of supermartensitic stainless steel

    DEFF Research Database (Denmark)

    Nießen, Frank; Tiedje, Niels Skat; Hald, John

    2017-01-01

    The kinetics model for multi-component diffusion DICTRA was applied to analyze the formation and retainment of δ-ferrite during solidification and cooling of GX4-CrNiMo-16-5-1 cast supermartensitic stainless steel. The obtained results were compared with results from the Schaeffler diagram......, equilibrium calculations and the Scheil model in Thermo-Calc, and validated by using microscopy and energy dispersive X-ray spectroscopy for chemical analysis on a cast ingot. The kinetics model showed that micro-segregation from solidification homogenizes within 2–3 s (70 °C) of cooling, and that retained δ...

  3. Evolution of the Stability Work from Classic Retaining Walls to Mechanically Stabilized Earth Walls

    Directory of Open Access Journals (Sweden)

    Anghel Stanciu

    2008-01-01

    Full Text Available For the consolidation of soil mass and the construction of the stability works for roads infrastructure it was studied the evolution of these kinds of works from classical retaining walls - common concrete retaining walls, to the utilization in our days of the modern and competitive methods - mechanically stabilized earth walls. Like type of execution the variety of the reinforced soil is given by the utilization of different types of reinforcing inclusions (steel strips, geosynthetics, geogrids or facing (precast concrete panels, dry cast modular blocks, metal sheets and plates, gabions, and wrapped sheets of geosynthetics.

  4. Reduced Operating Time but Not Blood Loss With Cruciate Retaining Total Knee Arthroplasty

    Science.gov (United States)

    Vermesan, Dinu; Trocan, Ilie; Prejbeanu, Radu; Poenaru, Dan V; Haragus, Horia; Gratian, Damian; Marrelli, Massimo; Inchingolo, Francesco; Caprio, Monica; Cagiano, Raffaele; Tatullo, Marco

    2015-01-01

    Background There is no consensus regarding the use of retaining or replacing cruciate implants for patients with limited deformity who undergo a total knee replacement. Scope of this paper is to evaluate whether a cruciate sparing total knee replacement could have a reduced operating time compared to a posterior stabilized implant. Methods For this purpose, we performed a randomized study on 50 subjects. All procedures were performed by a single surgeon in the same conditions to minimize bias and only knees with a less than 20 varus deviation and/or maximum 15° fixed flexion contracture were included. Results Surgery time was significantly shorter with the cruciate retaining implant (P = 0.0037). The mean duration for the Vanguard implant was 68.9 (14.7) and for the NexGen II Legacy was 80.2 (11.3). A higher range of motion, but no significant Knee Society Scores at 6 months follow-up, was used as controls. Conclusions In conclusion, both implants had the potential to assure great outcomes. However, if a decision has to be made, choosing a cruciate retaining procedure could significantly reduce the surgical time. When performed under tourniquet, this gain does not lead to reduced blood loss. PMID:25584102

  5. Retaining nurses in metropolitan areas: insights from senior nurse and human resource managers.

    Science.gov (United States)

    Drennan, Vari M; Halter, Mary; Gale, Julia; Harris, Ruth

    2016-11-01

    To investigate the views of senior nurse and human resource managers of strategies to retain hospital nurses in a metropolitan area. Against a global shortage, retaining nurses is a management imperative for the quality of hospital services. Semi-structured interviews, thematically analysed. Metropolitan areas have many health organisations in geographical proximity, offering nurses choices in employer and employment. Senior nurse and human resource managers recognised the complexity of factors influencing nurse turnover, including those that 'pulled' nurses out of their jobs to other posts and factors that 'pushed' nurses to leave. Four themes emerged in retaining nurses: strategy and leadership, including analysis of workforce and leavers' data, remuneration, the type of nursing work and career development and the immediate work environment. In contexts where multiple organisations compete for nurses, addressing retention through strategic leadership is likely to be important in paying due attention and apportioning resources to effective strategies. Aside from good human resource management practices for all, strategies tailored to different segments of the nursing workforce are likely to be important. This metropolitan study suggests attention should be paid to strategies that address remuneration, progressing nursing careers and the immediate work environment. © 2016 The Authors Journal of Nursing Management Published by John Wiley & Sons Ltd.

  6. Arctic water tracks retain phosphorus and transport ammonium

    Science.gov (United States)

    Harms, T.; Cook, C. L.; Wlostowski, A. N.; Godsey, S.; Gooseff, M. N.

    2017-12-01

    Hydrologic flowpaths propagate biogeochemical signals among adjacent ecosystems, but reactions may attenuate signals by retaining, removing, or transforming dissolved and suspended materials. The theory of nutrient spiraling describes these simultaneous reaction and transport processes, but its application has been limited to stream channels. We applied nutrient spiraling theory to water tracks, zero-order channels draining Arctic hillslopes that contain perennially saturated soils and flow at the surface either perennially or in response to precipitation. In the Arctic, experimental warming results in increased availability of nitrogen, the limiting nutrient for hillslope vegetation at the study site, which may be delivered to aquatic ecosystems by water tracks. Increased intensity of rain events, deeper snowpack, earlier snowmelt, and increasing thaw depth resulting from climate change might support increased transport of nutrients, but the reactive capacity of hillslope flowpaths, including sorption and uptake by plants and microbes, could counter transport to regulate solute flux. Characteristics of flowpaths might influence the opportunity for reaction, where slower flowpaths increase the contact time between solutes and soils or roots. We measured nitrogen and phosphorus uptake and transient storage of water tracks through the growing season and found that water tracks retain inorganic phosphorus, but transport ammonium. Nutrient uptake was unrelated to transient storage, suggesting high capacity for nutrient retention by shallow organic soils and vegetation. These observations indicate that increased availability of ammonium, the biogeochemical signal of warming tundra, is propagated by hillslope flowpaths, whereas water tracks attenuate delivery of phosphorus to aquatic ecosystems, where its availability typically limits production.

  7. Bicruciate-retaining Total Knee Replacement Provides Satisfactory Function and Implant Survivorship at 23 Years.

    Science.gov (United States)

    Pritchett, James W

    2015-07-01

    One of the goals of a TKA is to approximate the function of a normal knee. Preserving the natural ligaments might provide a method of restoring close to normal function. Sacrifice of the ACL is common and practical during a TKA. However, this ligament is functional in more than 60% of patients undergoing a TKA and kinematic studies support the concept of bicruciate-retaining (that is, ACL-preserving) TKA; however, relatively few studies have evaluated patients treated with bicruciate-retaining TKA implants. I asked: (1) what is the long-term (minimum 20-year) survivorship, (2) what are the functional results, and (3) what are the reasons for revision of bicruciate-retaining knee arthroplasty prostheses? From January 1989 to September 1992, I performed 639 total knee replacements in 537 patients. Of these, 489 were performed in 390 patients using a bicruciate-retaining, minimally constrained device. During the period in question, this knee prosthesis was used for all patients observed intraoperatively to have an intact, functional ACL with between 15° varus and 15° valgus joint deformity. There were 234 women and 156 men with a mean age at surgery of 65 years (range, 42-84 years) and a primary diagnosis of osteoarthritis in 89%. The patella was resurfaced in all knees. The mean followup was 23 years (range, 20-24 years). At the time of this review, 199 (51%) patients had died and 31 (8%) patients were lost to followup, leaving 160 (41%) patients (214 knees) available for review. Component survivorship was determined by competing-risks analysis and Kaplan Meier survivorship analysis with revision for any reason as the primary endpoint. Patients were evaluated every 2 years to assess ROM, joint laxity, knee stability, and to determine American Knee Society scores. The Kaplan-Meier survivorship was 89% (95% CI, 82%-93%) at 23 years with revision for any reason as the endpoint. Competing-risks survivorship was 94% (95% CI, 91%%-96 %) at 23 years. At followup, the mean

  8. Magnet-retained implant-supported overdentures: review and 1-year clinical report.

    Science.gov (United States)

    Ceruti, Paola; Bryant, S Ross; Lee, Jun-Ho; MacEntee, Michael I

    2010-01-01

    Open-field aluminum-nickle-cobalt magnets have been used in prosthodontics for many years, but success has been limited because these magnets are susceptible to corrosion by the saliva and because their retentive force is weak relative to the initial retention offered by mechanical attachments. More recently, magnets have been made from alloys of the rare earth elements samarium and neodymium, which provide stronger magnetic force per unit size. In addition, a new generation of laser-welded containers has improved protection from salivary corrosion. The current resurgence of interest in this type of attachment appears justified because, unlike mechanical attachments, magnets have potential for unlimited durability and might therefore be superior to mechanical ball or bar attachments for the retention of removable prostheses on implants. To date, no long-term prospective trials have been conducted to confirm the clinical durability of this new generation of magnets for retaining dentures on either teeth or implants. The aim of this study was to document initial clinical experiences and levels of satisfaction among edentulous patients treated with mandibular implant-supported overdentures retained using a new generation of rare-earth magnetic attachments. At the outset, all but one of the 17 patients had had several years of experience with implant-supported overdentures. During the first year, the mean overall satisfaction among these 17 patients increased from less than 70 to over 90 out of 100 (standardized visual analogue scale). No unusual difficulties were encountered in rendering the treatment or maintaining the attachments. This report offers preliminary evidence of the excellent potential of these magnets for retaining mandibular implant-supported overdentures.

  9. Estimating retained gas volumes in the Hanford tanks using waste level measurements

    International Nuclear Information System (INIS)

    Whitney, P.D.; Chen, G.; Gauglitz, P.A.; Meyer, P.A.; Miller, N.E.

    1997-09-01

    The Hanford site is home to 177 large, underground nuclear waste storage tanks. Safety and environmental concerns surround these tanks and their contents. One such concern is the propensity for the waste in these tanks to generate and trap flammable gases. This report focuses on understanding and improving the quality of retained gas volume estimates derived from tank waste level measurements. While direct measurements of gas volume are available for a small number of the Hanford tanks, the increasingly wide availability of tank waste level measurements provides an opportunity for less expensive (than direct gas volume measurement) assessment of gas hazard for the Hanford tanks. Retained gas in the tank waste is inferred from level measurements -- either long-term increase in the tank waste level, or fluctuations in tank waste level with atmospheric pressure changes. This report concentrates on the latter phenomena. As atmospheric pressure increases, the pressure on the gas in the tank waste increases, resulting in a level decrease (as long as the tank waste is open-quotes softclose quotes enough). Tanks with waste levels exhibiting fluctuations inversely correlated with atmospheric pressure fluctuations were catalogued in an earlier study. Additionally, models incorporating ideal-gas law behavior and waste material properties have been proposed. These models explicitly relate the retained gas volume in the tank with the magnitude of the waste level fluctuations, dL/dP. This report describes how these models compare with the tank waste level measurements

  10. Recruiting and Retaining Learners in Workplace Literacy Programs in New Zealand

    Science.gov (United States)

    Benseman, John

    2013-01-01

    Successful workplace literacy and numeracy programs are dependent on effective strategies to recruit and then retain course participants. This article reports on the recruitment strategies used in a large workplace literacy and numeracy project involving 535 workers in 18 courses. It provides an analysis of the strategies used, their rates of…

  11. Math and Science Teachers: Recruiting and Retaining California's Workforce. Policy Brief

    Science.gov (United States)

    EdSource, 2008

    2008-01-01

    Middle and high school math and science teachers provide the foundation for education in the growing science, technology, engineering, and mathematics fields. They are crucial to California's efforts to remain competitive in a global economy. This policy brief looks at the shortage and challenges involved in recruiting and retaining fully prepared…

  12. Differentiating the role of lithium and oxygen in retaining deuterium on lithiated graphite plasma-facing components

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, C. N. [Fusion Safety Program, Idaho National Laboratory, P.O. Box 1625-7113, Idaho Falls, Idaho 83415 (United States); School of Nuclear Engineering, Purdue University, 400 Central Drive, West Lafayette, Indiana 47907 (United States); Allain, J. P. [School of Nuclear Engineering, Purdue University, 400 Central Drive, West Lafayette, Indiana 47907 (United States); Department of Nuclear, Plasma and Radiological Engineering, University of Illinois at Urbana-Champaign, Illinois 61801 (United States); Luitjohan, K. E. [School of Nuclear Engineering, Purdue University, 400 Central Drive, West Lafayette, Indiana 47907 (United States); Krstic, P. S. [Institute for Advanced Computational Science, Stony Brook University, New York 11794 (United States); Department of Physics and Astronomy, University of Tennessee, Knoxville, Tennessee 37996 (United States); TheoretiK, Knoxville, Tennessee 379XX (United States); Dadras, J. [Department of Physics and Astronomy, University of Tennessee, Knoxville, Tennessee 37996 (United States); Department of Chemistry and Biochemistry, University of California Los Angeles, Los Angeles, California 90095 (United States); Skinner, C. H. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2014-05-15

    Laboratory experiments have been used to investigate the fundamental interactions responsible for deuterium retention in lithiated graphite. Oxygen was found to be present and play a key role in experiments that simulated NSTX lithium conditioning, where the atomic surface concentration can increase to >40% when deuterium retention chemistry is observed. Quantum-classical molecular dynamic simulations elucidated this oxygen-deuterium effect and showed that oxygen retains significantly more deuterium than lithium in a simulated matrix with 20% lithium, 20% oxygen, and 60% carbon. Simulations further show that deuterium retention is even higher when lithium is removed from the matrix. Experiments artificially increased the oxygen content in graphite to ∼16% and then bombarded with deuterium. X-ray photoelectron spectroscopy showed depletion of the oxygen and no enhanced deuterium retention, thus demonstrating that lithium is essential in retaining the oxygen that thereby retains deuterium.

  13. Designing high pressure containers for research- principles and applications

    International Nuclear Information System (INIS)

    Anandkumar, V.

    1997-01-01

    The high pressure scientist looks for a well engineered pressure apparatus for high pressure experiments for 1 kbar (0.1 GPa) and above. Often, a variety of difficulties including the choice of materials, design configuration, optimum utilisation of the strength of materials used in the design, are encountered. This article is intended to help the high pressure scientist to select the design approach for pressure retaining container. The limitations imposed by the strength of available materials and engineering standards in building high pressure containers are discussed. Engineering solutions to overcome these limitations with optimal utilisation of the strength of the materials are also discussed. Novel methods to boost up the pressure retaining capacity like multilayered design and autofrettaging are compared along with their relative advantages and disadvantages. Special methods by which it is possible to attain pressures which are several times the yield strength of the materials of construction are presented. In this aspects such as the basis of the codes and their relevance in the design of high pressure equipment will also be described. Discussions are centered around the methods to tackle situations where experimental constraints dictate requirements of pressures higher than those permitted by design codes. Safety features are also discussed. (author)

  14. Changes in the edentulous maxilla in persons wearing implant-retained mandibular overdentures

    NARCIS (Netherlands)

    Narhi, TO; Geertman, ME; Hevinga, M; Abdo, H; Kalk, W

    Statement of problem. It has been suggested that risk for severe resorption in the anterior maxilla is increased in persons wearing mandibular implant-retained overdentures. However, little information is available about the changes in the edentulous maxilla after mandibular implant treatment.

  15. Computer-navigated minimally invasive total knee arthroplasty for patients with retained implants in the femur

    Directory of Open Access Journals (Sweden)

    Sung-Yen Lin

    2014-08-01

    Full Text Available Total knee arthroplasty (TKA in patients with knee arthritis and retained implants in the ipsilateral femur is a challenge for knee surgeons. Use of a conventional intramedullary femoral cutting guide is not practical because of the obstruction of the medullary canal by implants. Previous studies have shown that computer-assisted surgery (CAS can help restore alignment in conventional TKA for patients with knee arthritis with retained femoral implants or extra-articular deformity, without the need for implant removal or osteotomy. However, little has been published regarding outcomes with the use of navigation in minimally invasive surgery (MIS-TKA for patients with this complex knee arthritis. MIS has been proven to provide less postoperative pain and faster recovery than conventional TKA, but MIS-TKA in patients with retained femoral implants poses a greater risk in limb malalignment. The purpose of this study is to report the outcome of CAS-MIS-TKA in patients with knee arthritis and retained femoral implants. Between April 2006 and March 2008, eight patients with knee arthritis and retained femoral implants who underwent the CAS-MIS-TKA were retrospectively reviewed. Three of the eight patients had extra-articular deformity, including two femur bones and one tibia bone, in the preoperative examination. The anteroposterior, lateral, and long-leg weight-bearing radiographs carried out at 3-month follow-up was used to determine the mechanical axis of lower limb and the position of components. The mean preoperative femorotibial angle in patients without extra-articular deformity was 3.8° of varus and was corrected to 4.6° of valgus. With the use of navigation in MIS-TKA, the two patients in this study with extra-articular femoral deformity also obtained an ideal postoperative mechanical axis within 2° of normal alignment. Overall, there was a good restoration of postoperative mechanical alignment in all cases, with a mean angle of 0.4° of

  16. Comparison of gap frame designs and materials for precision cathode strip chambers

    International Nuclear Information System (INIS)

    Horvath, J.A.; Pratuch, S.M.; Belser, F.C.

    1993-01-01

    Precision cathode strip chamber perimeter designs that incorporate either continuous or discrete-post gap frames are analyzed. The effects of ten design and material combinations on gravity sag, mass, stress, and deflected shape are evaluated. Procedures are recommended for minimizing mass in the chamber perimeter region while retaining structural integrity and electrical design latitude

  17. Interventions for hiring, retaining and training district health systems managers in low- and middle-income countries.

    Science.gov (United States)

    Rockers, Peter C; Bärnighausen, Till

    2013-04-30

    District managers are playing an increasingly important role in determining the performance of health systems in low- and middle-income countries as a result of decentralization. To assess the effectiveness of interventions to hire, retain and train district health systems managers in low- and middle-income countries. We searched a wide range of international databases, including the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE. We also searched online resources of international agencies, including the World Bank, to find relevant grey literature. Searches were conducted in December 2011. District health systems managers are those persons who are responsible for overseeing the operations of the health system within a defined, subnational geographical area that is designated as a district. Hiring and retention interventions include those that aim to increase the attractiveness of district management positions, as well as those related to hiring and retention processes, such as private contracting. Training interventions include education programs to develop future managers and on-the-job training programs for current managers. To be included, studies needed to use one of the following study designs: randomized controlled trial, nonrandomized controlled trial, controlled before-and-after study, and interrupted time series analysis. We report measures of effect in the same way that the primary study authors have reported them. Due to the varied nature of interventions included in this review we could not pool data across studies. Two studies met our inclusion criteria. The findings of one study conducted in Cambodia provide low quality evidence that private contracts with international nongovernmental organizations (NGOs) for district health systems management ('contracting-in') may improve health care access and utilization. Contracting-in increased use of antenatal care by 28% and use of public facilities by 14%. However, contracting

  18. MDCT in the diagnosis of small-bowel obstruction by a retained ...

    African Journals Online (AJOL)

    assessment of complications such as abscess formation, fistula. MDCT in the diagnosis of small-bowel obstruction by a retained surgical swab. M. Bindapersad, M.B. Ch.B., F.C.Rad. (Diag.) N. Govender, M.B. Ch.B. Department of Radiology, Chris Hani Baragwanath Hospital and Faculty of Health Sciences, University of the ...

  19. Electrosynthesized MIPs for transferrin: Plastibodies or nano-filters?

    Science.gov (United States)

    Zhang, Xiaorong; Yarman, Aysu; Erdossy, Júlia; Katz, Sagie; Zebger, Ingo; Jetzschmann, Katharina J; Altintas, Zeynep; Wollenberger, Ulla; Gyurcsányi, Róbert E; Scheller, Frieder W

    2018-05-15

    Molecularly imprinted polymer (MIP) nanofilms for transferrin (Trf) have been synthesized on gold surfaces by electro-polymerizing the functional monomer scopoletin in the presence of the protein target or around pre-adsorbed Trf. As determined by atomic force microscopy (AFM) the film thickness was comparable with the molecular dimension of the target. The target (re)binding properties of the electro-synthesized MIP films was evaluated by cyclic voltammetry (CV) and square wave voltammetry (SWV) through the target-binding induced permeability changes of the MIP nanofilms to the ferricyanide redox marker, as well as by surface plasmon resonance (SPR) and surface enhanced infrared absorption spectroscopy (SEIRAS) of the immobilized protein molecules. For Trf a linear concentration dependence in the lower micromolar range and an imprinting factor of ~5 was obtained by SWV and SPR. Furthermore, non-target proteins including the iron-free apo-Trf were discriminated by pronounced size and shape specificity. Whilst it is generally assumed that the rebinding of the target or of cross-reacting proteins exclusively takes place at the polymer here we considered also the interaction of the protein molecules with the underlying gold transducers. We demonstrate by SWV that adsorption of proteins suppresses the signal of the redox marker even at the bare gold surface and by SEIRAS that the treatment of the MIP with proteinase K or NaOH only partially removes the target protein. Therefore, we conclude that when interpreting binding of proteins to directly MIP-covered gold electrodes the interactions between the protein and the gold surface should also be considered. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Characterization of bulk-micromachined direct-bonded silicon nanofilters

    Science.gov (United States)

    Tu, Jay K.; Huen, Tony; Szema, Robert; Ferrari, Mauro

    1998-03-01

    The ability to separate 30-100 nm particles - nanofiltration - is critical for many biomedical applications. Where this filtration needs to be absolute, such as for viral elimination in the blood fractionation process, the large variations in pore size found with conventional polymeric filters can lead to the unwanted presence of viruses in the filtrate. To overcome this problem, we have developed a filter with micromachined channels sandwiched between two bonded silicon wafers. These channels are formed through the selective deposition and then removal of a thermally-grown oxide, the thickness of which can be controlled to +/- 4 percent for 30 nm pores. In this paper, we will present both the gas and liquid characterization, and the filtration studies done on 44 and 100 nm beads.

  1. Drafting & Design Technology. Technical Committee Report.

    Science.gov (United States)

    Idaho State Dept. of Education, Boise. Div. of Vocational Education.

    This Technical Committee Report prepared by industry representatives in Idaho lists the skills currently necessary for an employee in that state to obtain a job in drafting and design technology, retain a job once hired, and advance in that occupational field. (Task lists are grouped according to duty areas generally used in industry settings, and…

  2. A technique for the management of screw access opening in cement-retained implant restorations

    Directory of Open Access Journals (Sweden)

    Hamid Kermanshah

    2014-01-01

    Full Text Available Introduction: Abutment screw loosening has been considered as a common complication of implant-supported dental prostheses. This problem is more important in cement-retained implant restorations due to their invisible position of the screw access opening. Case Report: This report describes a modified retrievability method for cement-retained implant restorations in the event of abutment screw loosening. The screw access opening was marked with ceramic stain and its porcelain surface was treated using hydrofluoric acid (HF, silane, and adhesive to bond to composite resin. Discussion: The present modified technique facilitates screw access opening and improves the bond between the porcelain and composite resin.

  3. Total Knee Arthroplasty Designed to Accommodate the Presence or Absence of the Posterior Cruciate Ligament

    Directory of Open Access Journals (Sweden)

    Melinda K. Harman

    2014-01-01

    Full Text Available Evidence for selecting the same total knee arthroplasty prosthesis whether the posterior cruciate ligament (PCL is retained or resected is rarely documented. This study reports prospective midterm clinical, radiographic, and functional outcomes of a fixed-bearing design implanted using two different surgical techniques. The PCL was completely retained in 116 knees and completely resected in 43 knees. For the entire cohort, clinical knee (96±7 and function (92±13 scores and radiographic outcomes were good to excellent for 84% of patients after 5–10 years in vivo. Range of motion averaged 124˚±9˚, with 126 knees exhibiting ≥120° flexion. Small differences in average knee flexion and function scores were noted, with the PCL-resected group exhibiting an average of 5° more flexion but an average function score that was 7 points lower compared to the PCL-retained group. Fluoroscopic analysis of 33 knees revealed stable tibiofemoral translations. This study demonstrates that a TKA articular design with progressive congruency in the lateral compartment can provide for femoral condyle rollback in maximal flexion activities and achieve good clinical and functional performance in patients with PCL-retained and PCL-resected TKA. This TKA design proved suitable for use with either surgical technique, providing surgeons with the choice of maintaining or sacrificing the PCL.

  4. Bifurcations in the response of a flexible rotor in squeeze-film dampers with retainer springs

    International Nuclear Information System (INIS)

    Inayat-Hussain, Jawaid I.

    2009-01-01

    Squeeze-film dampers are commonly used in conjunction with rolling-element or hydrodynamic bearings in rotating machinery. Although these dampers serve to provide additional damping to the rotor-bearing system, there have however been some cases of rotors mounted in these dampers exhibiting non-linear behaviour. In this paper a numerical study is undertaken to determine the effects of design parameters, i.e., gravity parameter, W, mass ratio, α, and stiffness ratio, K, on the bifurcations in the response of a flexible rotor mounted in squeeze-film dampers with retainer springs. The numerical simulations were undertaken for a range of speed parameter, Ω, between 0.1 and 5.0. Numerical results showed that increasing K causes the onset speed of bifurcation to increase, whilst an increase of α reduces the onset speed of bifurcation. For a specific combination of K and α values, the onset speed of bifurcation appeared to be independent of W. The instability of the rotor response at this onset speed was due to a saddle-node bifurcation for all the parameter values investigated in this work with the exception of the combination of α = 0.1 and K = 0.5, where a secondary Hopf bifurcation was observed. The speed range of non-synchronous response was seen to decrease with the increase of α; in fact non-synchronous rotor response was totally absent for α=0.4. With the exception of the case α = 0.1, the speed range of non-synchronous response was also seen to decrease with the increase of K. Multiple responses of the rotor were observed at certain values of Ω for various combinations of parameters W, α and K, where, depending on the values of the initial conditions the rotor response could be either synchronous or quasi-periodic. The numerical results presented in this work were obtained for an unbalance parameter, U, value of 0.1, which is considered as the upper end of the normal unbalance range of most practical rotor systems. These results provide some insights

  5. Local benefits of retaining natural vegetation for soil retention and hydrological services

    CSIR Research Space (South Africa)

    O'Farrell, PJ

    2009-08-01

    Full Text Available for their conservation on private land. This study explored the benefits of retaining renosterveld fragments at the farm-scale based on the hydrological and soil retention services they provide. Rainfall simulations were carried out at paired sites of renosterveld...

  6. Designing Shared Virtual Reality Gaming Experiences in Local Multi-platform Games

    OpenAIRE

    Liszio , Stefan; Masuch , Maic

    2016-01-01

    Part 4: Short Papers; International audience; Designing multiplayer virtual reality games is a challenging task since immersion is easily destroyed by real world influences. However, providing fun and social virtual reality experiences is inevitable for establishing virtual reality gaming as a convincing new medium. We propose a design approach to integrate social interactions into the game design while retaining immersion, and present design methods to implement this approach. Furthermore, w...

  7. Prosthetic management of mid-facial defect with magnet-retained silicone prosthesis.

    Science.gov (United States)

    Buzayan, Muaiyed M

    2014-02-01

    Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication. To provide an aesthetic and stable facial prosthesis, the extra-oral prosthesis was fabricated using silicone material, while the intra-oral defect was restored with obturator prosthesis, and then both prostheses were connected and attached to each other using magnets. This clinical report describes the rehabilitation of a large mid-facial defect with a two-piece prosthesis. The silicone facial prosthesis was made hollow and lighter by using an acrylic framework. Two acrylic channels were included within the facial prosthesis to provide the patient with clean and patent airways. A sectional mid-facial prosthesis was made and retained in place by using magnets, which resulted in a significant improvement in the aesthetical and functional outcome without the need for plastic surgery. Silicone prostheses are reliable alternatives to surgery and should be considered in selected cases.

  8. Localization of nuclear retained mRNAs in Saccharomyces cerevisiae

    DEFF Research Database (Denmark)

    Thomsen, Rune; Libri, Domenico; Boulay, Jocelyne

    2003-01-01

    site of transcription, and known S. cerevisiae nuclear structures such as the nucleolus and the nucleolar body. Our results show that retained SSA4 RNA localizes to an area in close proximity to the SSA4 locus. On deletion of Rrp6p and release from the genomic locus, heat shock mRNAs produced...

  9. A 3-year follow-up study of overdentures retained by mini-dental implants.

    Science.gov (United States)

    Preoteasa, Elena; Imre, Marina; Preoteasa, Christina Teodora

    2014-01-01

    This study evaluated overdentures retained by mini-dental implants (MDIs) as a treatment option for complete edentulism during a 3-year follow-up period. This observational clinical study included completely edentulous patients who were treated with MDI-retained overdentures. The MDIs were supplied by the manufacturer. Twenty-three patients received 7 maxillary and 16 mandibular MDI overdentures retained by 110 MDIs. Of the 36 MDIs placed in the maxilla, 8 failed (in two patients), 2 had compromised survival, 3 displayed satisfactory survival, and 23 were successful. Of the 74 MDIs placed in the mandible, 11 displayed satisfactory survival and 63 were successful. The marginal bone loss was more pronounced for the MDIs placed mesially (intercalated), in areas of decreased ridge width and bone density, and with lower values of insertion torque. The overdentures fractured in seven patients; in 4 of them, this corresponded to the implant housing area. Self-reported reasons for patient dissatisfaction included occasional pain under the overdenture (n = 5) and instability of the maxillary antagonist complete denture (n = 4). Based on this research, considering its limitations, it is possible to conclude that survival rates and health status are better for MDI overdentures applied in the mandible than for those applied in the maxilla. The most severe prosthetic complications encountered were overdenture base fracture, matrix detachment, and instability of the maxillary antagonist denture.

  10. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    OpenAIRE

    Kim, Chang-Soon; Duong, Hieu Pham; Park, Jung-Chul; Shin, Hyun-Seung

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-...

  11. Longitudinal Improvement in Periodontal Parameters between RPD Abutment Teeth with Direct and Indirect Retainers, after Periodontal Therapy.

    Science.gov (United States)

    Almeida, Mariana Linhares; Tôrres, Ana Clara Soares de Paiva; de Oliveira, Kleiton Clécio; Calderon, Patrícia Dos Santos; Carreiro, Adriana da Fonte Porto; Gurgel, Bruno César de Vasconcelos

    2018-03-06

    To evaluate the effect of basic periodontal treatment on clinical periodontal parameters associated with abutment teeth of patients with mandibular Kennedy class I removable partial dentures (RPD) 18 months after treatment. Thirty patients with periodontal disease were treated and evaluated according to the following periodontal parameters: visible plaque index (VPI), bleeding on probing (BOP), probing depth (PD), gingival recession (GR), clinical attachment loss (CAL), and keratinized mucosa (KM). These parameters were compared between abutment teeth with direct and indirect retainers at baseline, and after 6 and 18 months. Data were analyzed by Friedman Test and Wilcoxon Test for all variables. Most patients (n = 26; 86.7%) included in the study were female and had a mean age of 61 years (±7.54). Results showed that VPI and BOP decreased over time, and that VPI values were higher in abutment teeth with direct retainers (p = 0.001). There was a reduction in PD after 6 months, which was maintained up to 18 months. In general, abutment teeth with direct retainers had significantly higher values for PD, GR, and CAL (p = 0.029). Data also indicated that the parameters for VPI, BOP, and PD improved; however, abutment teeth with direct retainers presented smaller improvements, compared with abutment teeth with indirect retainers, which presented significant improvements for almost all variables. Periodontal treatment and oral hygiene care of patients were adequate for maintenance of adequate periodontal conditions, regardless of the use of prostheses. © 2018 by the American College of Prosthodontists.

  12. Umbrella Wheel - a stair-climbing and obstacle-handling wheel design concept

    DEFF Research Database (Denmark)

    Iversen, Simon; Jouffroy, Jerome

    2017-01-01

    This paper proposes a new design for stair-climbing using a wheel that can split into segments and walk up stairs or surmount other obstacles often found where humans traverse, while still being able to retain a perfectly round shape for traveling on smooth ground. Using this change of configurat......This paper proposes a new design for stair-climbing using a wheel that can split into segments and walk up stairs or surmount other obstacles often found where humans traverse, while still being able to retain a perfectly round shape for traveling on smooth ground. Using this change...... of configuration, staircases with a wide range of dimensions can be covered efficiently and safely. The design, named Umbrella Wheel, can consist of as many wheel segments as desired, and as few as two. A smaller or higher number of wheel segments has advantages and disadvantages depending on the specific...

  13. Spherical powder for retaining thermosetting acrylic resin veneers.

    Science.gov (United States)

    Tanaka, T; Atsuta, M; Uchiyama, Y; Nakabayashi, N; Masuhara, E

    1978-03-01

    1. Nine different sizes of spherical powder were prepared, and their effectiveness as retentive devices was evaluated against those available commercially. 2. Smaller-diameter spherical powder (No. 5) gave the best results of all retaining devices tested. 3. The physical properties of the resins play an important role in the retentive strength with No. 5 retention beads. The retentive strength was reduced when brittle resin was used. 4. The retentive strength of the resin veneer was greatly affected by the angle of stress at the incisal resin. The retentive strength increased as the angle between the longitudinal axis of the specimen and the direction of stress decreased.

  14. Changes in the blood indicators and body condition of high yielding Holstein cows with retained placenta and ketosis

    Directory of Open Access Journals (Sweden)

    Zenon Nogalski

    2012-01-01

    Full Text Available The aim of this study was to determine the effect of changes in body condition in the dry period and the early lactation period on the incidence of retained placenta and ketosis in 94 high-yielding Holstein-Friesian cows. Body condition scoring was performed every two weeks from the beginning of the dry period until week 18 of lactation. Blood for the measuring of indicators of metabolism was sampled in weeks 1 and 2 ante partum and in weeks 1, 2, 3, 7 and 15 post partum. Retained placenta was reported in 11 cows, and ketosis was diagnosed in 18 animals. One week ante partum, the serum profile of cows diagnosed with ketosis during lactation revealed 0.52 mmol/l β-hydroxybutyric acid and 0.29 mmol/l non-esterified fatty acids on average. One week post partum, the serum profile of cows with ketosis revealed 1.59 mmol/l β-hydroxybutyric acid and 1.09 mmol/l non-esterified fatty acids and cows with retained placenta 1.65 and 1.41, respectively. From the week 5 ante partum to the point of lowest body condition the average body condition loss reached 1.4 points in cows with retained placenta, 1.1 points in cows with ketosis, and 0.8 points in healthy cows. Retained placenta and ketosis increased significantly conception rates by 0.47 and 0.50, respectively. Our results show that monitoring changes in the body condition and non-esterified fatty acids and β-hydroxybutyric acid blood levels in high-yielding cows in the transition period, followed by taking relevant disease-control measures, may be effective in reducing the incidence of retained placenta and ketosis in dairy cattle herds.

  15. Redistribution Principle Approach for Evaluation of Seismic Active Earth Pressure Behind Retaining Wall

    Science.gov (United States)

    Maskar, A. D.; Madhekar, S. N.; Phatak, D. R.

    2017-11-01

    The knowledge of seismic active earth pressure behind the rigid retaining wall is very essential in the design of retaining wall in earthquake prone regions. Commonly used Mononobe-Okabe (MO) method considers pseudo-static approach. Recently there are many pseudo-dynamic methods used to evaluate the seismic earth pressure. However, available pseudo-static and pseudo-dynamic methods do not incorporate the effect of wall movement on the earth pressure distribution. Dubrova (Interaction between soils and structures, Rechnoi Transport, Moscow, 1963) was the first, who considered such effect and till date, it is used for cohesionless soil, without considering the effect of seismicity. In this paper, Dubrova's model based on redistribution principle, considering the seismic effect has been developed. It is further used to compute the distribution of seismic active earth pressure, in a more realistic manner, by considering the effect of wall movement on the earth pressure, as it is displacement based method. The effects of a wide range of parameters like soil friction angle (ϕ), wall friction angle (δ), horizontal and vertical seismic acceleration coefficients (kh and kv); on seismic active earth pressure (Kae) have been studied. Results are presented for comparison of pseudo-static and pseudo-dynamic methods, to highlight the realistic, non-linearity of seismic active earth pressure distribution. The current study results in the variation of Kae with kh in the same manner as that of MO method and Choudhury and Nimbalkar (Geotech Geol Eng 24(5):1103-1113, 2006) study. To increase in ϕ, there is a reduction in static as well as seismic earth pressure. Also, by keeping constant ϕ value, as kh increases from 0 to 0.3, earth pressure increases; whereas as δ increases, active earth pressure decreases. The seismic active earth pressure coefficient (Kae) obtained from the present study is approximately same as that obtained by previous researchers. Though seismic earth

  16. Delayed inflammation associated with retained perfluorocarbon liquid

    Directory of Open Access Journals (Sweden)

    S Pradeep

    2011-01-01

    Full Text Available A 55-year-old woman, with history of cataract surgery 1 year back, presented with features of ocular inflammation for last 3 months. She had no history of any other intraocular surgery. On examination, anterior segment showed frothy material in the inferior angle with moderate anterior chamber reaction (cells+/flare+ and sulcus intraocular lens with large posterior capsule rent. Fundoscopy showed multiple, small to medium-sized transparent bubbles of perfluorocarbon liquid (PFCL with membranes in the vitreous cavity. Ultrasonography confirmed the presence of PFCL in the vitreous cavity. Pars plana vitrectomy with anterior chamber wash was done which led to good visual recovery. To conclude, retained PFCL can cause late onset fibrinous inflammation after a quiescent period but surgical intervention may lead to good visual outcome.

  17. The Effect of Cash Dividend, Retained Earnings, and Stock Price of Manufacturing Company Listed In Indonesia Stock Exchange

    Directory of Open Access Journals (Sweden)

    Farah Margaretha

    2015-03-01

    Full Text Available This study aims to determine the effect of cash dividends per share, retained earnings per share, earnings per share, and leverage on the stock price of manufacture industry in Indonesia from 2008-2012. Research used secondary data in which the source was obtained indirectly through an intermediary medium or data processed from literatures and reports associated with this research. Independent variables in this study (x are cash dividends per share, retained earnings per share, earnings per share, and leverage, while the dependent variable (y is stock price. The samples used were 23 companies with purposive sampling method. The empirical results of this study indicate that cash dividends per share, retained earnings per share, earnings per share, and leverage has significant effect on the stock price. It is therefore the higher stock price will attract investors to invest their money. Hence, companies and investors need to attend cash dividends per share, retained earnings per share, earnings per share, and leverage as factors that affect the increase or decrease of the stock price. 

  18. 14-Day thawed plasma retains clot enhancing properties and inhibits tPA-induced fibrinolysis.

    Science.gov (United States)

    Huebner, Benjamin R; Moore, Ernest E; Moore, Hunter B; Shepherd-Singh, Raymond; Sauaia, Angela; Stettler, Gregory R; Nunns, Geoffrey R; Silliman, Christopher C

    2017-11-01

    Plasma-first resuscitation attenuates trauma-induced coagulopathy (TIC); however, the logistics of plasma-first resuscitation require thawed plasma (TP) be readily available due to the obligatory thawing time of fresh frozen plasma (FFP). The current standard is storage of TP for up to 5 days at 4°C, based on factor levels at outdate, for use in patients at risk for TIC, but there remains a 2.2% outdated wastage rate. However, the multitude of plasma proteins in attenuating TIC remains unknown. We hypothesize that TP retains the ability to enhance clotting and reduce tPA-induced fibrinolysis at 14-day storage. FFP was thawed and stored at 4°C at the following intervals: 14, 10, 7, 5, 3, and 1-day prior to the experiment. Healthy volunteers underwent blood draws followed by 50% dilution with TP stored at previously mentioned intervals as well as FFP, normal saline (NS), albumin, and whole blood (WB) control. Samples underwent tPA-modified (75 ng/mL) thrombelastography (TEG) with analysis of R-time, angle, maximum amplitude (MA), and LY30. TEG properties did not change significantly over the thawed storage. 14-day TP retained the ability to inhibit tPA-induced hyperfibrinolysis (median LY30% 9.6%) similar to FFP (5.6%), WB (14.6%), and superior to albumin (59.3%) and NS (58.1%). 14-day TP also retained faster clot formation (median angle, 66.2°) and superior clot strength (MA, 61.5 mm) to albumin (34.8°, 21.6 mm) and NS (41.6°, 32.2 mm). TP plasma stored for 14 days retains clot-enhancing ability and resistance to clot degradation similar to FFP. A clinical trial is needed to validate these in vitro results. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Stability of retained austenite in multi-phase microstructure during austempering and its effect on the ductility of a low carbon steel

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Z.J.; Ren, Y.Q.; Zhou, W.H. [School of Materials Science and Engineering, University of Science and Technology, Beijing (China); Yang, J.R. [Department of Materials Science and Engineering, National Taiwan University, Taipei, Taiwan (China); Shang, C.J., E-mail: cjshang@ustb.edu.cn [School of Materials Science and Engineering, University of Science and Technology, Beijing (China); Misra, R.D.K. [Laboratory for Excellence in Advanced Steel Research, Center for Structural and Functional Materials, Institute for Material Research and Innovation, University of Louisiana at Lafayette, P.O. Box 44130, Lafayette, LA 70503 (United States)

    2014-05-01

    The contribution of multi-phase microstructure and retained austenite on mechanical properties of austempered and intercritical annealed Fe–0.23C–1.8Mn–1.35Si (wt%) steel was studied. The multi-phase microstructure comprised of intercritical ferrite (IF), bainite/martensite, and retained austenite. During austempering, the retained austenite was stabilized, which was studied using a combination of experimental (XRD, TEM) and thermodynamic analysis. The termination of bainitic transformation combined with carbon rejection into residual austenite during the second step austempering treatment is believed to be the underlying basis for stabilization of retained austenite. This led to significant increase in uniform and total elongation (25% and 36%, respectively) and the product of tensile strength and % elongation was 33 GPa%. The work hardening behavior of retained austenite exhibited a three-stage process such that necking was delayed. The increased work hardening rate is attributed to the multi-phase microstructure and TRIP effect.

  20. Fiscal 2000 achievement report on research and development of industrial technologies. Research and development of synergy ceramics (Research and development of ultrahigh temperature gas turbine for power generation); 2000 nendo sangyo kagaku gijutsu kenkyu kaihatsu seika hokokusho. Synergy ceramics no kenkyu kaihatsu (hatsuden'yo chokoon gas turbine no kenkyu kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The fruits of fiscal 2000 efforts to develop high temperature energy materials and ultraprecision materials are briefly described. Activities are conducted in the four fields of (1) materials derivation and advanced evaluation/design technologies, (2) application technologies, (3) common base technologies, and (4) multifunction realization process evaluation. Discussed in field (1) are high temperature energy materials, high performance active materials, fundamental technologies for member designing, active materials for dealing with environmental gas, silicon based high resistance energy materials, porous multiple layer ceramic materials, macro-/micro-scale stress analysis technology, and microfracture analysis technology. Discussed in field (2) are heat resistant and damage tolerant materials, heat shielding materials and energy absorbing materials, and nanofilter materials capable of selective separation. In the study of active materials specific for environmental gas, a catalyst is developed, stable at high temperatures and capable of treating NOx selectively. The catalyst is a layered product comprising Ba hexaaluminate layers and stabilized zirconia layers. (NEDO)

  1. Fiscal 2000 achievement report on research and development of industrial technologies. Research and development of synergy ceramics (Research and development of ultrahigh temperature gas turbine for power generation); 2000 nendo sangyo kagaku gijutsu kenkyu kaihatsu seika hokokusho. Synergy ceramics no kenkyu kaihatsu (hatsuden'yo chokoon gas turbine no kenkyu kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The fruits of fiscal 2000 efforts to develop high temperature energy materials and ultraprecision materials are briefly described. Activities are conducted in the four fields of (1) materials derivation and advanced evaluation/design technologies, (2) application technologies, (3) common base technologies, and (4) multifunction realization process evaluation. Discussed in field (1) are high temperature energy materials, high performance active materials, fundamental technologies for member designing, active materials for dealing with environmental gas, silicon based high resistance energy materials, porous multiple layer ceramic materials, macro-/micro-scale stress analysis technology, and microfracture analysis technology. Discussed in field (2) are heat resistant and damage tolerant materials, heat shielding materials and energy absorbing materials, and nanofilter materials capable of selective separation. In the study of active materials specific for environmental gas, a catalyst is developed, stable at high temperatures and capable of treating NOx selectively. The catalyst is a layered product comprising Ba hexaaluminate layers and stabilized zirconia layers. (NEDO)

  2. Factors related to employers' intent to hire, retain and accommodate cancer survivors: the Singapore perspective.

    Science.gov (United States)

    Mak, Angela Ka Ying; Ho, Shirley S; Kim, Hyo Jung

    2014-12-01

    Despite the growing importance of cancer and return-to-work issues in occupational rehabilitation literature in the last decade, academic discussion is largely limited to survivors' perspectives and some exploratory studies from the employer side. This paper applies two classic theoretical models-Theory of Planned Behavior and Social Cognitive Theory-and key measures from previous studies to identify explicit relationships that explain employer factors to hire and retain cancer survivors. Data were collected from online surveys with senior management executives and senior human resource specialists from various organizations in Singapore, with a total of 145 responses. The 72-item survey instrument included a series of independent variables: (1) Attitudes toward cancer and cancer survivors; (2) Employers' efficacy; (3) Perceived moral obligation; (4) Employers' experience; (5) Outcome expectations; (6) Employment situation; (7) Social norms; and (8) Incentives, and dependent variables: (a) Employers' intention to hire cancer survivors; and (b) Employers' intention to retain cancer survivors. Regression analyses showed that the top three factors related to employers' intention to retain cancer survivors are perceived moral obligations (β = .39, p employment situation (β = .17, p Employers' efficacy was associated with intention to hire (β = .22, p employer and an employee when it comes to retaining cancer survivors and government incentives for hiring cancer survivors in the workforce. The present study provided an avenue to implement the proposed model-a potential study framework for the management of cancer survivors at work. Findings revealed that different messages should be tailored to employers toward hiring and retention issues and provided useful guidelines for employer education materials.

  3. Effective post-construction best management practices (BMPs) to infiltrate and retain stormwater runoff.

    Science.gov (United States)

    2017-06-01

    Performance analyses of newly constructed linear BMPs in retaining stormwater run-off from 1 in. precipitation in : post-construction highway applications and urban areas were conducted using numerical simulations and field : observation. A series of...

  4. An integrated framework for transmission cost allocation retaining efficiency concepts

    Energy Technology Data Exchange (ETDEWEB)

    Lima, J.W. Marangon [Escola Federal de Engenharia de Itajuba, MG (Brazil); Gorenstin, B G; Vieira Filho, X [Centro de Pesquisas de Energia Eletrica (CEPEL), Rio de Janeiro, RJ (Brazil); Chipp, H J; Alvarenga Filho, S [ELETROBRAS, Rio de Janeiro, RJ (Brazil); Hirota, M [Companhia Energetica de Sao Paulo (CESP), SP (Brazil); Pereira, M V.F. [Power System Research, Inc., Rio de Janeiro, RJ (Brazil)

    1994-12-31

    This paper describes a methodology for allocating transmission costs among utilities and wheeling agents. The proposed approach is based on the extension of marginal cost theory to take into account discrete component sizes and economy of scale, while retaining desirable economic properties such as revenue reconciliation and incentives for all participants to remain in the pool. The methodology is illustrated in case studies with the Brazilian system. (author) 21 refs., 1 fig., 3 tabs.

  5. [Efficacy of retained rectal posterior mucosa in procedure for prolapse and hemorrhoids].

    Science.gov (United States)

    Zheng, Chenguo; Jin, Chun; Lian, Shaoxiong; Jin, Dingguo

    2014-12-01

    To evaluate the efficacy and necessity of retained rectal posterior mucosa in procedure for prolapse and hemorrhoids (PPH). Clinical data of 260 cases with severe hemorrhoids in our hospital from January 2010 to May 2012 were analyzed retrospectively. A total of 132 cases with severe hemorrhoids excluding in rectal posterior wall were enrolled in retained rectal posterior mucosa in PPH (improvement group), other 128 cases of severe hemorrhoids were assigned to PPH (conventional group). Operative parameters, efficacy and complication after operation were compared. Two groups of patients received successful operations. Postoperative pain duration, frequency of analgesic drugs and postoperative hospital stay in improvement group were significantly reduced [(1.3 ± 0.5) d vs. (4.8 ± 0.7) d, 1.1 ± 0.3 vs. 5.9 ± 0.6, (5.2 ± 0.8) d vs. (5.8 ± 0.5) d, all Phemorrhoids excluding in rectal posterior wall can significantly reduce postoperative complications. But long-term efficacy needs further observation.

  6. Does retained-seed priming drive the evolution of serotiny in drylands? An assessment using the cactus Mammillaria hernandezii.

    Science.gov (United States)

    Santini, Bianca A; Martorell, Carlos

    2013-02-01

    Serotinous plants retain their seeds for a long time. In deserts, retained seeds undergo hydration-dehydration cycles and thus may become primed. Priming enhances germination and seedling vigor. We test the hypothesis that serotiny evolves because it provides a site protected from predators in which seeds can become primed. Rainfall-cued dispersal of primed seeds may enhance this effect. We tested this hypothesis with Mammillaria hernandezii through protein-content analyses; field and laboratory germination experiments with primed, unprimed, and retained seeds; and fitness estimations from demographic models. Hydration-dehydration cycles induced priming, enhancing germination. Artificial priming and retention in the parent plant for 1 yr induced similar changes in seed protein patterns, suggesting that priming occurs naturally while seeds are retained. Under field conditions, germination of seeds retained for 1 yr more than doubled that of seeds of the same cohort that were not primed or that remained buried for 1 yr. The first seeds to germinate died rapidly. Serotinous plants whose seeds underwent priming had higher fitness than those whose seeds were in the soil seed bank or that did not experience priming. Priming in soil seed banks may be costly because of high predation, so seed protection during priming is sufficient to promote the evolution of serotiny. Bet hedging contributes to this process. Rapid germination of primed seeds that respond to brief rainfall events is disadvantageous because such rainfall is insufficient for seedling survival. Serotinous species counteract this cost by cueing dispersal with heavy precipitation.

  7. Measuring air layer volumes retained by submerged floating-ferns Salvinia and biomimetic superhydrophobic surfaces

    Directory of Open Access Journals (Sweden)

    Matthias J. Mayser

    2014-06-01

    Full Text Available Some plants and animals feature superhydrophobic surfaces capable of retaining a layer of air when submerged under water. Long-term air retaining surfaces (Salvinia-effect are of high interest for biomimetic applications like drag reduction in ship coatings of up to 30%. Here we present a novel method for measuring air volumes and air loss under water. We recorded the buoyancy force of the air layer on leaf surfaces of four different Salvinia species and on one biomimetic surface using a highly sensitive custom made strain gauge force transducer setup. The volume of air held by a surface was quantified by comparing the buoyancy force of the specimen with and then without an air layer. Air volumes retained by the Salvinia-surfaces ranged between 0.15 and 1 L/m2 depending on differences in surface architecture. We verified the precision of the method by comparing the measured air volumes with theoretical volume calculations and could find a good agreement between both values. In this context we present techniques to calculate air volumes on surfaces with complex microstructures. The introduced method also allows to measure decrease or increase of air layers with high accuracy in real-time to understand dynamic processes.

  8. Tensile test and interface retention forces between wires and composites in lingual fixed retainers.

    Science.gov (United States)

    Paolone, Maria Giacinta; Kaitsas, Roberto; Obach, Patricia; Kaitsas, Vasilios; Benedicenti, Stefano; Sorrenti, Eugenio; Barberi, Fabrizio

    2015-06-01

    In daily orthodontic clinical practice retention is very important, and lingual retainers are part of this challenge. The failure of lingual retainers may be due to many factors. The aim of this study was to assess the retention forces and mechanical behavior of different types of wires matched with different kinds of composites in lingual retainers. A tensile test was performed on cylindrical composite test specimens bonded to orthodontic wires. The specimens were constructed using four different wires: a straight wire (Remanium .016×.022″ Dentaurum), two round twisted wires (Penta One .0215″ Masel, Gold Penta Twisted .0215″ Gold N'braces) and a rectangular braided wire (D-Rect .016×.022″ Ormco); and three composites: two micro-hybrids (Micro-Hybrid Enamel Plus HFO Micerium, and Micro-Hybrid SDR U Dentsply) and a micro-nano-filled composite (Micro-Nano-Filled Transbond LR 3M). The test was performed at a speed of 10mm/min on an Inström device. The wire was fixed with a clamp. The results showed that the bonding between wires and composites in lingual fixed retainers seemed to be lowest for rectangular smooth wires and increased in round twisted and rectangular twisted wires where the bonding was so strong that the maximum tension/bond strength was greater than the ultimate tensile strength of the wire. The highest values were in rectangular twisted wires. Concerning the composites, hybrid composites had the lowest interface bonding values and broke very quickly, while the nano- and micro-composites tolerated stronger forces and displayed higher bonding values. The best results were observed with the golden twisted wire and reached 21.46 MPa with the Transbond composite. With the rectangular braided wire the retention forces were so high that the Enamel Plus composite fractured when the load exceeded 154.6 N/MPa. When the same wire was combined with the Transbond LR either the wire or the composite broke when the force exceeded 240 N. The results of this

  9. The Examination of Retaining Walls in Landscape Architecture: The Example of Trabzon City

    Directory of Open Access Journals (Sweden)

    Özge Volkan Aksu

    2010-11-01

    Full Text Available Number of problems about city order and its vision has been increasing rapidly. There is two main factors that causes visual pollution. The first factor is that cities are in an unplanned and dense urbanization process which has serious effects on appearance of a city. The second factor is retaining walls used densely in Trabzon city because of its open land structure. These walls which are set up for environmental construction security should be rebuilt with using some landscape plans so that the vision of dense concrete can be reduced. In this study, retaining walls are examined regarded landscape architecture. The continuous situation in Trabzon city is revealed with the help of an examination place, and also some suggestions for preventing the landscape problems which includes vegetal, structural and both vegetal-structural solutions are thrown out for consideration.

  10. Precision attachment-retained removable partial dentures. Part 3. General practitioner results up to 2 years.

    Science.gov (United States)

    Owall, B; Jönsson, L

    1998-01-01

    The aim of this study was to analyze the techniques, production problems, and 2-year results of attachment-retained removable partial denture (RPD) treatment provided by general practitioners in Sweden. At a major dental laboratory, consecutive cases involving new production of crowns, or of fixed partial dentures (FPDs) and RPDs retained with precision attachments, were studied. Parameters of the dentition, crown or FPD, type and brand of attachment, etc, as well as early satisfaction by dentist and patient, were recorded using specially designed forms at the dental laboratory and questionnaires for the dentists. After 2 years, questionnaires were again sent out to the dentists to record complications and patients' and dentists' opinions of the results. The sample gathered totaled 83 constructions. After 2 years, responses for 57 patients, all of whom had distal-extension RPDs, were received. Most drop-outs in the study were explicable. The most frequently cited reasons for using attachments were esthetics and need for crowning the teeth abutting the RPD. McCollum rigid slide attachment was the predominant brand used (43% of constructions). Dentists and patients were dissatisfied with 6% of the constructions. During the first 2 years, 22 of 57 constructions were complication-free. Seventeen had attachment complications and 9 had serious complications related to the abutment teeth or RPDs. A comparison between these 2 groups revealed that those with complications had every second abutment root-canal treated and a root post, while the group without complications had every fifth abutment root-canal treated. There were many technical and biotechnical complications and failures; the exact ratio, however, depended on the definition of "complications" and "failure." The 2-year results also deviated considerably from the dentists' opinions of the early results.

  11. Macroeconomic effects of zero corporate income tax on retained earnings

    OpenAIRE

    Jaan Masso; Jaanika Meriküll

    2011-01-01

    International tax competition had led to a lowering of corporate tax rates worldwide. Estonia was the first country to reduce the tax rate on retained earnings to zero, while distributed profits remained taxed at the pre-reform level. This paper seeks to analyse the effects of this unique tax reform implemented in year 2000. We apply a neoclassical exogenous growth general equilibrium model with an extension for endogenous corporate finance. Our findings indicate that the reform had a strong ...

  12. Magnet-Retained Two-Mini-Implant Overdenture: Clinical and Mechanical Consideration

    Directory of Open Access Journals (Sweden)

    Yuichi Ishida

    2016-10-01

    Full Text Available Two-implant overdentures have become the accepted treatment for restoring mandibular edentulism. The dimensions of regular implants sometimes limit their use, such as in the case of narrow ridges. Mini-implants with reduced diameters (less than 3.0 mm enable insertion into narrow ridges. A magnet-retained two-mini-implant overdenture system was developed and is described in this paper. Additionally, we describe a clinical mandibular procedure using the system and evaluate its biomechanical performance.

  13. 24 CFR 1000.36 - How long must a recipient retain records regarding exceptions made to the conflict of interest...

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false How long must a recipient retain records regarding exceptions made to the conflict of interest provisions? 1000.36 Section 1000.36 Housing... AMERICAN HOUSING ACTIVITIES General § 1000.36 How long must a recipient retain records regarding exceptions...

  14. Clinics in diagnostic imaging (133). Retained placenta from an intra-abdominal pregnancy.

    Science.gov (United States)

    Win, T; Tang, P H; Lim, T Y

    2011-01-01

    A 29-year-old Indonesian woman presented with abdominal pain seven months after an intra-abdominal pregnancy. Ultrasonography revealed a cystic mass in the pelvis and magnetic resonance imaging showed an umbilical stump within it, indicating a retained placenta. This was removed surgically, and on histology, an infarcted placenta was confirmed.

  15. Functional characterisation of an intron retaining K+ transporter of barley reveals intron-mediated alternate splicing

    KAUST Repository

    Shahzad, K.

    2015-01-01

    Intron retention in transcripts and the presence of 5 and 3 splice sites within these introns mediate alternate splicing, which is widely observed in animals and plants. Here, functional characterisation of the K+ transporter, HvHKT2;1, with stably retained introns from barley (Hordeum vulgare) in yeast (Saccharomyces cerevisiae), and transcript profiling in yeast and transgenic tobacco (Nicotiana tabacum) is presented. Expression of intron-retaining HvHKT2;1 cDNA (HvHKT2;1-i) in trk1, trk2 yeast strain defective in K+ uptake restored growth in medium containing hygromycin in the presence of different concentrations of K+ and mediated hypersensitivity to Na+. HvHKT2;1-i produces multiple transcripts via alternate splicing of two regular introns and three exons in different compositions. HKT isoforms with retained introns and exon skipping variants were detected in relative expression analysis of (i) HvHKT2;1-i in barley under native conditions, (ii) in transgenic tobacco plants constitutively expressing HvHKT2;1-i, and (iii) in trk1, trk2 yeast expressing HvHKT2;1-i under control of an inducible promoter. Mixed proportions of three HKT transcripts: HvHKT2;1-e (first exon region), HvHKT2;1-i1 (first intron) and HvHKT2;1-i2 (second intron) were observed. The variation in transcript accumulation in response to changing K+ and Na+ concentrations was observed in both heterologous and plant systems. These findings suggest a link between intron-retaining transcripts and different splice variants to ion homeostasis, and their possible role in salt stress.

  16. design and operations challenges of a single toggle jaw crusher

    African Journals Online (AJOL)

    HOD

    [13] showed that the difference between Wall and Bond energies for hard rocks are .... advantages of retaining the structural design of the crusher and decreasing the ..... of aw crusher supporting structure fatigue failure”,. Stro niški Vestnik ...

  17. Intestinal Obstruction due to Complete Transmural Migration of a Retained Surgical Sponge into the Intestine

    Directory of Open Access Journals (Sweden)

    Takashi Kato

    2012-12-01

    Full Text Available A 56-year-old woman with a history of gynecological surgery for cervical cancer 18 years previously was referred to our hospital for colicky abdominal pain, nausea and vomiting. Intestinal obstruction was diagnosed by contrast-enhanced computed tomography (CT which showed dilation of the small intestine and suggested obstruction in the terminal ileum. In addition, CT showed a thick-walled cavitary lesion communicating with the proximal jejunum. 18F-fluorodeoxyglucose positron emission tomography showed abnormal uptake at the same location as the cavitary lesion revealed by CT. The patient underwent laparotomy for the ileus and resection of the cavitary lesion. At laparotomy, we found a retained surgical sponge in the ileum 60 cm from the ileocecal valve. The cavitary tumor had two fistulae communicating with the proximal jejunum. The tumor was resected en bloc together with the transverse colon, part of the jejunum and the duodenum. Microscopic examination revealed fibrous encapsulation and foreign body giant cell reaction. Since a retained surgical sponge without radiopaque markers is extremely difficult to diagnose, retained surgical sponge should be considered in the differential diagnosis of intestinal obstruction in patients who have undergone previous abdominal surgery.

  18. A statistical model for telecommunication link design

    Science.gov (United States)

    Yuen, J. H.

    1975-01-01

    An evaluation is conducted of the current telecommunication link design technique and a description is presented of an alternative method, called the probability distribution method (PDM), which is free of the disadvantages of the current technique while retaining its advantages. The PDM preserves the simplicity of the design control table (DCT) format. The use of the DCT as a management design control tool is continued. The telecommunication link margin probability density function used presents the probability of achieving any particular value of link performance. It is, therefore, possible to assess the performance risk and other tradeoffs.

  19. Complete overdentures retained by mini implants: A systematic review.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Batista, Victor Eduardo de Souza; Júnior, Joel Ferreira Santiago; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza

    2017-02-01

    The purpose of this systematic review was to evaluate the use of mini implants to retain complete overdentures in terms of survival rates of mini implants, marginal bone loss, satisfaction, and quality of life. This report followed the PRISMA Statement and PICO question. This review has been registered at PROSPERO under the number CRD42016036141. Two independent reviewers performed a comprehensive search of studies published until September 2016 and listed in the PubMed/MEDLINE, Embase, and The Cochrane Library databases. The focused question was: is the use of mini implants feasible for prosthodontic rehabilitation with complete overdentures? The 24 studies selected for review evaluated 1273 patients whose mean age was 65.93 years; these patients had received 2494 mini implants and 386 standard implants for retaining overdenture prosthesis. The mean follow-up time was 2.48 years (range: 1-7 years). There was a higher survival rate of mini implants (92.32%). More frequent failures for maxillary (31.71%) compared with mandibular arches (4.89%). The majority of studies revealed marginal bone loss values similar to those of standard implants (overdenture prosthesis is considered an alternative treatment when standard treatment is not possible, since it presents high survival rates, acceptable marginal bone loss, and improvements in variables related to satisfaction and quality of life. Based on the results of this study, the use of a minimum 4 and 6 mini implants can be considered a satisfactory treatment option for rehabilitation of the mandibular and maxillary arches respectively with a complete overdenture. Copyright © 2016. Published by Elsevier Ltd.

  20. Wrong-Site Surgery, Retained Surgical Items, and Surgical Fires : A Systematic Review of Surgical Never Events.

    Science.gov (United States)

    Hempel, Susanne; Maggard-Gibbons, Melinda; Nguyen, David K; Dawes, Aaron J; Miake-Lye, Isomi; Beroes, Jessica M; Booth, Marika J; Miles, Jeremy N V; Shanman, Roberta; Shekelle, Paul G

    2015-08-01

    Serious, preventable surgical events, termed never events, continue to occur despite considerable patient safety efforts. To examine the incidence and root causes of and interventions to prevent wrong-site surgery, retained surgical items, and surgical fires in the era after the implementation of the Universal Protocol in 2004. We searched 9 electronic databases for entries from 2004 through June 30, 2014, screened references, and consulted experts. Two independent reviewers identified relevant publications in June 2014. One reviewer used a standardized form to extract data and a second reviewer checked the data. Strength of evidence was established by the review team. Data extraction was completed in January 2015. Incidence of wrong-site surgery, retained surgical items, and surgical fires. We found 138 empirical studies that met our inclusion criteria. Incidence estimates for wrong-site surgery in US settings varied by data source and procedure (median estimate, 0.09 events per 10,000 surgical procedures). The median estimate for retained surgical items was 1.32 events per 10,000 procedures, but estimates varied by item and procedure. The per-procedure surgical fire incidence is unknown. A frequently reported root cause was inadequate communication. Methodologic challenges associated with investigating changes in rare events limit the conclusions of 78 intervention evaluations. Limited evidence supported the Universal Protocol (5 studies), education (4 studies), and team training (4 studies) interventions to prevent wrong-site surgery. Limited evidence exists to prevent retained surgical items by using data-matrix-coded sponge-counting systems (5 pertinent studies). Evidence for preventing surgical fires was insufficient, and intervention effects were not estimable. Current estimates for wrong-site surgery and retained surgical items are 1 event per 100,000 and 1 event per 10,000 procedures, respectively, but the precision is uncertain, and the per

  1. A Success Story: Recruiting & Retaining Underrepresented Minority Doctoral Students in Biomedical Engineering

    Science.gov (United States)

    Reichert, William M.

    2006-01-01

    There are various ways to succeed in recruiting and retaining underrepresented minority (URM) doctoral students; but key to them all is the creation of real student-faculty relationships, which demonstrate by example that diversity and excellence can and should coexist. This cannot be delegated or done indirectly, and no amount of outreach, campus…

  2. Composition and quantities of retained gas measured in Hanford waste tanks 241-U-103, S-106, BY-101, and BY-109

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, L.A.; Antoniak, Z.I.; Bates, J.M.

    1997-12-01

    This report provides the results obtained for the single-shell tanks (SSTs) sampled with the Retained Gas Sampler (RGS) during 1997: Tanks 241-U-103, 241-S-106, 241-BY-101, and 241-BY-109. The RGS is a modified version of the core sampler used at Hanford. It is designed specifically to be used in concert with the gas extraction equipment in the hot cell to capture and extrude a gas-containing waste sample in a hermetically sealed system. The four tanks represent several different types of flammable gas SSTs. Tank U-103 is on the Flammable Gas Watch List (FGWL) and is one of the highest-priority group of SSTs that show evidence of significant gas retention. Tank S-106, though not a FGWL tank, has a uniquely high barometric pressure response and continuing rapid surface level rise, indicating a large and increasing volume of retained gas. Tanks BY-101 and BY-109 are not on the FGWL but were chosen to test the effect of recent salt-well pumping on gas retention. Section 2 of this report provides an overview of the process by which retained gases in the Hanford tanks are sampled and analyzed. A detailed description of the procedure used to reduce and analyze the data is provided in Section 3. Tank-by-tank results are covered in Section 4 (with the data presented in the order in which the tanks were sampled), and an RGS system performance overview is given in Section 5. Section 6 presents conclusions from these analyses and recommendations for further research. The cited references are listed in Section 7. Appendix A describes the procedures used to extract gas and ammonia from the samples, Appendix B contains detailed laboratory data from each of the tanks, and Appendix C gives field sampling data.

  3. Composition and quantities of retained gas measured in Hanford waste tanks 241-U-103, S-106, BY-101, and BY-109

    International Nuclear Information System (INIS)

    Mahoney, L.A.; Antoniak, Z.I.; Bates, J.M.

    1997-12-01

    This report provides the results obtained for the single-shell tanks (SSTs) sampled with the Retained Gas Sampler (RGS) during 1997: Tanks 241-U-103, 241-S-106, 241-BY-101, and 241-BY-109. The RGS is a modified version of the core sampler used at Hanford. It is designed specifically to be used in concert with the gas extraction equipment in the hot cell to capture and extrude a gas-containing waste sample in a hermetically sealed system. The four tanks represent several different types of flammable gas SSTs. Tank U-103 is on the Flammable Gas Watch List (FGWL) and is one of the highest-priority group of SSTs that show evidence of significant gas retention. Tank S-106, though not a FGWL tank, has a uniquely high barometric pressure response and continuing rapid surface level rise, indicating a large and increasing volume of retained gas. Tanks BY-101 and BY-109 are not on the FGWL but were chosen to test the effect of recent salt-well pumping on gas retention. Section 2 of this report provides an overview of the process by which retained gases in the Hanford tanks are sampled and analyzed. A detailed description of the procedure used to reduce and analyze the data is provided in Section 3. Tank-by-tank results are covered in Section 4 (with the data presented in the order in which the tanks were sampled), and an RGS system performance overview is given in Section 5. Section 6 presents conclusions from these analyses and recommendations for further research. The cited references are listed in Section 7. Appendix A describes the procedures used to extract gas and ammonia from the samples, Appendix B contains detailed laboratory data from each of the tanks, and Appendix C gives field sampling data

  4. How to Retain the Trust of Patients and Families When We Will Not Provide the Treatment They Want.

    Science.gov (United States)

    Howe, Edmund G

    2015-01-01

    How might clinicians best try to retain the trust of patients and family members after clinicians oppose giving a treatment? If clinicians can maintain the trust of patients and families in these situations, this may soften what may be the greatest possible loss--the death of a loved one. I discuss what clinicians seeking to retain trust should not do--namely impose their values and reason wrongly--and introduce strategies that clinicians may use to reduce both. I present five principles that clinicians can follow to try to retain trust, with examples that illustrate each. I suggest specific interventions that clinicians can make, especially when they anticipate that a patient and/or family may, in time, want a treatment that is futile. Copyright 2015 The Journal of Clinical Ethics. All rights reserved.

  5. [Retaining and transformation of incoming soil N from highland to adjacent terrestrial water body in riparian buffer zone].

    Science.gov (United States)

    Wang, Qing-cheng; Yu, Hong-li; Yao, Qin; Han, Zhuang-xing; Qiao, Shu-liang

    2007-11-01

    Highland soil nitrogen can enter adjacent water body via erosion and leaching, being one of the important pollutants in terrestrial water bodies. Riparian buffer zone is a transitional zone between highland and its adjacent water body, and a healthy riparian buffer zone can retain and transform the incoming soil N through physical, biological, and biochemical processes. In this paper, the major pathways through which soil nitrogen enters terrestrial water body and the mechanisms the nitrogen was retained and transformed in riparian buffer zone were introduced systematically, and the factors governing the nitrogen retaining and transformation were analyzed from the aspects of hydrological processes, soil characters, vegetation features, and human activities. The problems existing in riparian buffer zone study were discussed, and some suggestions for the further study in China were presented.

  6. Survival of flexible, braided, bonded stainless steel lingual retainers : a historic cohort study

    NARCIS (Netherlands)

    Foek, D. J. Lie Sam; Ozcan, M.; Verkerke, G. J.; Sandham, John; Dijkstra, P. U.

    The objectives of this study were to retrospectively evaluate the clinical survival rate of flexible, braided, rectangular bonded stainless steel lingual retainers, and to investigate the influence of gender, age of the patient, and operator experience on survival after orthodontic treatment at the

  7. PM-HIP research for structural and pressuring retaining applications within the electric power industry

    International Nuclear Information System (INIS)

    Gandy, David W.

    2015-01-01

    For more than 60 years now, the nuclear power industry has relied on structural and pressure retaining materials generated via established manufacturing practices such as casting, plate rolling-and-welding, forging, drawing, and/or extrusion. During the past three years, EPRI has been leading the development and introduction of another established process, powder metallurgy and hot Isostatic pressing (PM/HIP), for pressure retaining applications in electric power industry. The research includes assessment of two primary alloys: 316L stainless steel and Grade 91 creep-strength enhanced ferritic steels, for introduction into the ASME Boiler and Pressure Vessel Code. Continuing DOE and EPRI research on other structural/pressure retaining alloys such as Alloy 690, SA 508 Class 1, Alloy 625, hard-facing materials, and others are also underway. This research will have a tremendous impact as we move forward over the next few decades on the selection of new alloys and components for advanced light water reactors and small modular reactors. Furthermore, fabrication of high alloy materials/components may require the use of new manufacturing processes to achieve acceptable properties for higher temperature applications such as those in Generation IV applications. Current research by EPRI and DOE will be reviewed and emphasis will be targeted at advanced applications where PM/HIP may be applied in the future. (authors)

  8. Implant-retained overdentures for young children with severe oligodontia: a series of four cases.

    Science.gov (United States)

    Filius, Marieke A P; Vissink, Arjan; Raghoebar, Gerry M; Visser, Anita

    2014-09-01

    The treatment need is high in children with severe oligodontia and anodontia, because they often have functional and esthetic problems owing to missing teeth. Because the intraforaminal region barely grows after eruption of the permanent mandibular incisors, dental implant treatment should be considered a treatment option for these children. The purpose of our study was to assess the treatment outcomes regarding satisfaction and the care and aftercare of implant-retained mandibular overdentures in a series of 4 young children without erupted mandibular teeth from either severe oligodontia (n = 3) or anodontia (n = 1). Four children without erupted mandibular teeth, aged 6 to 13 years, were provided with an implant-retained overdenture on 2 implants. The surgical and prosthetic care and aftercare were scored by the clinicians. Also, the patients and their parents were queried about how satisfied they were with the overdenture. The median follow-up of the patients was 5.2 years (range 3.2 to 8.4). No implants were lost, no cases of peri-implantitis occurred, and the need for treatment and aftercare was low. Patient and parent satisfaction with this treatment was high. A 2-implant, retained overdenture in children with no erupted mandibular teeth is a safe treatment modality when appropriate treatment and aftercare can be provided. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Design Analysis and Observed Performance of a Tieback Anchored Pile Wall in Sand

    Directory of Open Access Journals (Sweden)

    Jian-Yong Han

    2017-01-01

    Full Text Available This paper aims to study the design process and service performance of a deep excavation supported by tieback anchored pile walls. The design procedure and design approaches for deep excavation in China are described. Based on the excavation case history for Shenyang, China, design results obtained using the elastic method and the finite element method (FEM are compared and analyzed. Special emphasis is given to the analysis of horizontal wall deformations, internal forces in the wall, earth pressures on the wall, ground surface settlements, and stabilities of the excavation. The similarities and differences between the Chinese code (JGJ 120-2012 and the European code (EN 1997-1 for the design of geotechnical structures are presented based on a design example. Through the comparison, it is indicated that the Chinese code focuses on the design result, while the European code focuses on the design process. The crucial construction methods for reducing construction risk based on the excavation case history are described. The mechanical behaviors of the excavation retained by an anchored pile wall were investigated by analyzing observed field cases. The results provide good, practical guidelines for the design and construction of a tieback anchored pile wall retained excavation in sandy soil.

  10. Soft Roof Failure Mechanism and Supporting Method for Gob-Side Entry Retaining

    Directory of Open Access Journals (Sweden)

    Hongyun Yang

    2015-10-01

    Full Text Available To study the soft roof failure mechanism and the supporting method for a gateway in a gently inclined coal seam with a dip angle of 16° kept for gob-side entry retaining, and through the methodology of field investigation and numerical and analytical modeling, this paper analyzed the stress evolution law of roof strata at the working face end and determined that the sharp horizontal stress unloading phenomenon along the coal wall side did not appear after the working face advanced. Conversely, the horizontal stress along the gob side instantly decreased and the tensile stress produced, and the vertical stress in the central part of the roof had a higher reduction magnitude as well. An in-depth study indicates that the soft roof of the working face end subsided and seriously separated due to the effect of the front abutment pressure and the roof hanging length above the gob line, as well as certain other factors, including the rapid unloading of the lateral stress, tension and shear on the lower roof rock layer and dynamic disturbance. Those influencing factors also led to rapid crack propagation on a large scale and serious fracturing in the soft roof of the working face end. However, in the gob stress stabilized zone, the soft roof in the gob-side entry retaining has a shearing failure along the filling wall inside affected by the overburden pressure, rock bulking pressure, and roof gravity. To maintain the roof integrity, decrease the roof deformation, and enable the control of the working face end soft roof and the stabilization of the gob-side entry retaining roof, this study suggests that the preferred bolt installation angle for the soft roof situation is 70° based on the rock bolt extrusion strengthening theory.

  11. The Seismic Design of Waterfront Retaining Structures

    Science.gov (United States)

    1992-11-01

    h*ho Hf a. Surcharge 81’ ’ S2- I • 040. K A[ Vih . V,., H - H, ) • • - V,,.H,] , b. Effective horizontal earth pressure - B= 0 degrees Figure...distance between the anchor and the sheet pile. Tuo anchored bulkheads were in place in the harbor of San Antnnio, Chile , during the very large earthquake...Engineering, Santiago, Chile . Provost, J. 1981 (Jan). "DYNAFLOW - A Nonlinear Transient Finite Element Analysis Program, Report No. 81-SM-l, Princeton

  12. Stress analysis at bone-implant interface of single- and two-implant-retained mandibular overdenture using three-dimensional finite element analysis

    Directory of Open Access Journals (Sweden)

    Krishnakumar Lahoti

    2016-01-01

    Conclusion: Within the limitations of the study, it had been seen that stresses produced were the highest on HB and SB in single implant-retained mandibular overdenture while stresses produced across the denture as well as implant were the highest in two-implant-retained mandibular overdenture.

  13. Effect of gamma-irradiation to prevent the spoilage of 'retainer type Kamaboko'

    International Nuclear Information System (INIS)

    Ito, Hitoshi; Iizuka, Hiroshi.

    1978-01-01

    The species of main microorganisms which can grow in retainer-Kamaboko a kind of fish meat jelly products were Bacillus subtilis and B. pumilus at 20 0 C, and B. pumilus, B. megaterium, b. cereus, Pseudomonas and yeasts at 10 0 C. When Kamaboko was stored at 5 0 C, microorganisms capable to grow were the species of Pseudomonas, Brevibacterium, Aeromonas and yeasts. Irradiation of Kamaboko at 300 krad and 450 krad reduced the aforementioned flora to the Bacillus and yeasts, and the storage life of Kamaboko was extended about 2 times at 10 0 C. The growth of Bacillus strains at 10 0 C was suppressed for 3 days or more after destruction to about 95% of the total viable cells by irradiation at 300 krad. The putrefaction in retainer-Kamaboko was brought mainly by Bacillus, which seemed to be originated mainly from starch at a manufacturing process. The number of microorganisms in Potato starch was 200 per gram, and they were consisted mainly of Bacillus. These bacteria in starch could be almost eliminated by means of 500 krad irradiation. (auth.)

  14. Ion beam analysis of hydrogen retained in carbon nanotubes and carbon films

    International Nuclear Information System (INIS)

    McDaniel, F.D.; Holland, O.W.; Naab, F.U.; Mitchell, L.J.; Dhoubhadel, M.; Duggan, J.L.

    2006-01-01

    Carbon nanotubes (CNTs) are studied as a possible hydrogen storage medium for future energy needs. Typically, hydrogen is stored in the CNTs by exposure of the material to a high-pressure H 2 atmosphere at different temperatures. The maximum hydrogen concentrations stored following this method and measured using ion beam analysis do not exceed 1 wt.%. Introduction of defects by ion irradiation (i.e. implantation) prior to high-pressure H 2 treatment, offers an alternative method to activate H adsorption and enhance the chemisorption of hydrogen. This is a preliminary work where hydrogen was introduced into single-wall nanotubes and carbon films by low-energy (13.6 keV) hydrogen ion implantation. Elastic recoil detection was used to measure the quantity and depth distribution of hydrogen retained in the carbonaceous materials. Results show that there are substantial differences in the measured profiles between the CNT samples and the vitreous carbon. On another hand, only ∼43% of the implanted hydrogen in the CNTs is retained in the region where it should be located according to the SRIM simulations for a solid carbon sample

  15. The retained templates as "helpers" for the spherical meso-silica in adsorption of heavy metals and impacts of solution chemistry.

    Science.gov (United States)

    Liang, Zhijie; Shi, Wenxin; Zhao, Zhiwei; Sun, Tianyi; Cui, Fuyi

    2017-06-15

    The spherical mesoporous silica (meso-silica) MCM-41 and those with different dosage of the retained templates were prepared and characterized. Particularly, effects of the retained template and its dosage on the adsorption of typical heavy metals (Cu 2+ and Cd 2+ ) in the synthesized materials were investigated. The results indicated that the retained templates acted as "helpers" for the adsorption of Cu 2+ and Cd 2+ in the spherical meso-silica MCM-41, and the maximum adsorption capacities (Q max ) increased with the increase of the retained template dosage. The interaction between the metal ions and the cationic heads of the templates contributed to the enhancement effect due to the anions (Cl - and OH - ) electronically adsorbed on the interface of the template micelles. Additionally, the presented results indicated that the adsorption of Cu 2+ and Cd 2+ depended on pH and high ion strength of the solution but not on the coexisted humic acid. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Displacement of teeth without and with bonded fixed orthodontic retainers: 3D analysis using triangular target frames and optoelectronic motion tracking device.

    Science.gov (United States)

    Chakroun, Firas; Colombo, Vera; Lie Sam Foek, Dave; Gallo, Luigi Maria; Feilzer, Albert; Özcan, Mutlu

    2018-06-06

    The objective of this study was to evaluate the anterior tooth movement without and with bonded fixed orthodontic retainers under incremental loading conditions. Six extracted mandibular anterior human teeth were embedded in acrylic resin in True Form I Arch type and 3D reconstruction of Digital Volume Tomography (DVT) images (0.4 mm 3 voxels) were obtained. The anatomy of each tooth was segmented and digitally reconstructed using 3D visualization software for medical images (AMIRA, FEI SVG). The digital models of the teeth were repositioned to form an arch with constant curvature using a CAD software (Rhinoceros) and a base holder was designed fitting the shape of the roots. The clearance between the roots and their slot in the holder was kept constant at 0.3 mm to replicate the periodontal ligament thickness. The holder and the teeth were then manufactured by 3D printing (Objet Eden 260VS, Stratasys) using a resin material for dental applications (E = 2-3 GPa). The 3D-printed teeth models were then positioned in the holder and the root compartments were filled with silicone. The procedure was repeated to obtain three identical arch models. Each model was tested for tooth mobility by applying force increasing from 5 to 30 N with 5 N increments applied perpendicular on the lingual tooth surface on the incisal one third (crosshead speed: 0.1 mm/s). The teeth on each model were first tested without retainer (control) and subsequently with the bonded retainers (braided bonded retainer wire; Multi-strand 1 × 3 high performance wire, 0.022″ × 0.016″). Tooth displacement was measured in terms of complicance (F/Δ movement) (N/mm) using custom-built optoelectronic motion tracking device (OPTIS) (accuracy: 5 µm; sampling rate: 200 Hz). The position of the object was detected through three LEDs positioned in a fixed triangular shape on a metal support (Triangular Target Frame). The measurements were repeated for three times for each tooth

  17. The dinoflagellates Durinskia baltica and Kryptoperidinium foliaceum retain functionally overlapping mitochondria from two evolutionarily distinct lineages

    Directory of Open Access Journals (Sweden)

    Keeling Patrick J

    2007-09-01

    Full Text Available Abtract Background The dinoflagellates Durinskia baltica and Kryptoperidinium foliaceum are distinguished by the presence of a tertiary plastid derived from a diatom endosymbiont. The diatom is fully integrated with the host cell cycle and is so altered in structure as to be difficult to recognize it as a diatom, and yet it retains a number of features normally lost in tertiary and secondary endosymbionts, most notably mitochondria. The dinoflagellate host is also reported to retain mitochondrion-like structures, making these cells unique in retaining two evolutionarily distinct mitochondria. This redundancy raises the question of whether the organelles share any functions in common or have distributed functions between them. Results We show that both host and endosymbiont mitochondrial genomes encode genes for electron transport proteins. We have characterized cytochrome c oxidase 1 (cox1, cytochrome oxidase 2 (cox2, cytochrome oxidase 3 (cox3, cytochrome b (cob, and large subunit of ribosomal RNA (LSUrRNA of endosymbiont mitochondrial ancestry, and cox1 and cob of host mitochondrial ancestry. We show that all genes are transcribed and that those ascribed to the host mitochondrial genome are extensively edited at the RNA level, as expected for a dinoflagellate mitochondrion-encoded gene. We also found evidence for extensive recombination in the host mitochondrial genes and that recombination products are also transcribed, as expected for a dinoflagellate. Conclusion Durinskia baltica and K. foliaceum retain two mitochondria from evolutionarily distinct lineages, and the functions of these organelles are at least partially overlapping, since both express genes for proteins in electron transport.

  18. Clinical Performance of One-Piece, Screw-Retained Implant Crowns Based on Hand-Veneered CAD/CAM Zirconia Abutments After a Mean Follow-up Period of 2.3 Years.

    Science.gov (United States)

    Schnider, Nicole; Forrer, Fiona Alena; Brägger, Urs; Hicklin, Stefan Paul

    The aim of this study was to evaluate the clinical performance of one-piece, screw-retained implant crowns based on hand-veneered computer-aided design/computer-aided manufacture (CAD/CAM) zirconium dioxide abutments with a crossfit connection at least 1 year after insertion of the crown. Consecutive patients who had received at least one Straumann bone level implant and one-piece, screw-retained implant crowns fabricated with CARES zirconium dioxide abutments were reexamined. Patient satisfaction, occlusal and peri-implant parameters, mechanical and biologic complications, radiologic parameters, and esthetics were recorded. A total of 50 implant crowns in the anterior and premolar region were examined in 41 patients. The follow-up period of the definitive reconstructions ranged from 1.1 to 3.8 years. No technical and no biologic complications had occurred. At the reexamination, 100% of the implants and reconstructions were in situ. Radiographic evaluation revealed a mean distance from the implant shoulder to the first visible bone-to-implant contact of 0.06 mm at the follow-up examination. Screw-retained crowns based on veneered CAD/CAM zirconium dioxide abutments with a crossfit connection seem to be a promising way to replace missing teeth in the anterior and premolar region. In the short term, neither failures of components nor complications were noted, and the clinical and radiographic data revealed stable hard and soft tissue conditions.

  19. Thermal stability of retained austenite in TRIP steels studied by synchrotron X-ray diffraction during cooling

    International Nuclear Information System (INIS)

    Dijk, N.H. van; Butt, A.M.; Zhao, L.; Sietsma, J.; Offerman, S.E.; Wright, J.P.; Zwaag, S. van der

    2005-01-01

    We have performed in situ X-ray diffraction measurements at a synchrotron source in order to study the thermal stability of the retained austenite phase in transformation induced plasticity steels during cooling from room temperature to 100 K. A powder analysis of the diffraction data reveals a martensitic transformation of part of the retained austenite during cooling. The fraction of austenite that transforms during cooling is found to depend strongly on the bainitic holding time and the composition of the steel. It is shown that that austenite grains with a lower average carbon concentration have a lower stability during cooling

  20. Why Some Hope Scholarship Recipients Retain the Scholarship and Others Lose It

    Science.gov (United States)

    Trant, Eleanore C.; Crabtree, Katelyn E.; Ciancio, Dennis J.; Hart, Leslie A.; Watson, Tiffany B.; Williams, Robert L.

    2015-01-01

    The study we report here examined parental, pre-course, and in-course predictors of students' probability of retaining (n = 136) or losing the HOPE scholarship (n = 41). The study was conducted in a multi-section, entry-level course (n = 203) for the Teacher-Education Program at a large state university in the southeastern U.S. Logistic regression…

  1. Controlling radiated emissions by design

    CERN Document Server

    Mardiguian, Michel

    2014-01-01

    The 3rd edition of Controlling Radiated Emissions by Design has been updated to reflect the latest changes in the field. New to this edition is material related to technical advances, specifically super-fast data rates on wire pairs, with no increase in RF interference. Throughout the book, details are given to control RF emissions using EMC design techniques. This book retains the step-by-step approach for incorporating EMC into every new design from the ground up. It describes the selection of quieter IC technologies, their implementation into a noise-free printed circuit layout, and the gathering of these into a low emissions package. Also included is how to design an I/O filter, along with connectors and cable considerations. All guidelines are supported throughout with comprehensive calculated examples. Design engineers, EMC specialists, and technicians will benefit from learning about the development of more efficient and economical control of emissions.

  2. STUDENTS’ RESPONSES TO INCLUSIVE DESIGN

    DEFF Research Database (Denmark)

    Herriott, Richard; Geert Jensen, Birgitte

    2012-01-01

    raw data on how students broke down the design problem into a variety of tasks: problem solving, data gathering and ideation among others. The work thus provides insight into how the problem is resolved into design solutions. The results provide some quantitative insight into how time is allocated......This paper looks at how students’ design process responds to the requirements of inclusive design. The background to the students´ brief was the concept of welfare technology. People wish to retain their customary life-style even as ageing brings with it a reduction in physical capability: loss...... of muscle strength and manual dexterity or deterioration of eyesight and hearing. They wish to remain in their familiar home and to be able to equip it with such necessary enhancements that help them cope with the minimum of outside support. At the Aarhus School of Architecture, Institute of Design...

  3. Intraoperative Ultrasound-Guided Removal of Retained Mini Sling Anchor Causing Vaginal Pain: A Case Report.

    Science.gov (United States)

    Almassi, Nima; Goldman, Howard B

    2016-01-01

    Since the introduction of the tension-free vaginal tape, the surgical management of female stress urinary incontinence has undergone a dramatic shift toward synthetic midurethral slings (MUSs). The evolution of the MUS has led to the development of the single incision mini sling (SIMS), a minimally invasive procedure that can be performed under local anesthesia. Complications arising after SIMS placement parallel those of the traditional MUS, including pelvic pain, dyspareunia, and mesh erosion. The patient in this case presented with persistent pelvic pain due to a retained SIMS anchor after having previously undergone SIMS placement and subsequent transvaginal exploration with mesh removal. We report the use of intraoperative ultrasound for identification and removal of the retained SIMS anchor.

  4. Improved Design of PECS to reduce Flow Instability for EU-APR1400

    International Nuclear Information System (INIS)

    Hwang, Do Hyun; Lee, Keunsung

    2014-01-01

    For EU-APR1400, PECS (Passive Ex-vessel corium retaining and Cooling System), so-called core catcher, was adopted to keep the integrity of basemat in containment by preventing MCCI (Molten Core Concrete Interaction) through retaining core debris and cooling corium outside the reactor vessel. In this paper, the improved design of PECS is presented to increase coolability by reducing flow instability in the region of cooling channel. In this paper, flow instability analysis was carried out using CFD code to find out the most improved design of PECS, which is to increase coolability by reducing bubble entrainment in the region of cooling channel. The reduction of bubble entrainment in the downcomer facilitates higher mass flow rates in the downcomer. Among presented four designed for the downcomer of PECS, the superstep design shows the highest mass flow rate and the lowest gas holdup in the downcomer as well as in the cooling channel. Compared with the existing design, the elimination of the horizontal part and the addition of an extra space above the vertical entrance to the downcomer seem to help the separation of the vapor

  5. The track nanotechnology

    International Nuclear Information System (INIS)

    Waheed, A.; Forsyth, D.; Watts, A.; Saad, A.F.; Mitchell, G.R.; Farmer, M.; Harris, P.J.F.

    2009-01-01

    The discipline now called Solid State Nuclear Track Detection (SSNTD) dates back to 1958 and has its roots in the United Kingdom. Its strength stems chiefly from factors such as its simplicity, small geometry, permanent maintenance of the nuclear record and other diversified applications. A very important field with exciting applications reported recently in conjuction with the nuclear track technique is nanotechnology, which has applications in biology, chemistry, industry, medicare and health, information technology, biotechnology, and metallurgical and chemical technologies. Nanotechnology requires material design followed by the study of the quantum effects for final produced applications in sensors, medical diagnosis, information technology to name a few. We, in this article, present a review of past and present applications of SSNTD suggesting ways to apply the technique in nanotechnology, with special reference to development of nanostructure for applications utilising nanowires, nanofilters and sensors.

  6. The track nanotechnology

    Energy Technology Data Exchange (ETDEWEB)

    Waheed, A. [British Institute of Technology and E-Commerce, London E7 9HZ (United Kingdom); Physics Department, University of Reading, Reading RG6 6AF (United Kingdom); Forsyth, D., E-mail: dforsyth@bite.ac.u [British Institute of Technology and E-Commerce, London E7 9HZ (United Kingdom); Watts, A. [Department of Physics, UCL, London Centre of Nanotechnology (LCN), 17-19 Gordon Street, London WC1H OAH (United Kingdom); Saad, A.F. [Physics Department, Faculty of Science, Garyounis University, Benghazi (Libyan Arab Jamahiriya); Mitchell, G.R. [British Institute of Technology and E-Commerce, London E7 9HZ (United Kingdom); Physics Department, University of Reading, Reading RG6 6AF (United Kingdom); Farmer, M. [British Institute of Technology and E-Commerce, London E7 9HZ (United Kingdom); Harris, P.J.F. [Physics Department, University of Reading, Reading RG6 6AF (United Kingdom)

    2009-10-15

    The discipline now called Solid State Nuclear Track Detection (SSNTD) dates back to 1958 and has its roots in the United Kingdom. Its strength stems chiefly from factors such as its simplicity, small geometry, permanent maintenance of the nuclear record and other diversified applications. A very important field with exciting applications reported recently in conjuction with the nuclear track technique is nanotechnology, which has applications in biology, chemistry, industry, medicare and health, information technology, biotechnology, and metallurgical and chemical technologies. Nanotechnology requires material design followed by the study of the quantum effects for final produced applications in sensors, medical diagnosis, information technology to name a few. We, in this article, present a review of past and present applications of SSNTD suggesting ways to apply the technique in nanotechnology, with special reference to development of nanostructure for applications utilising nanowires, nanofilters and sensors.

  7. Prevalence of IgG antibodies to human parvovirus B19 in haemophilia children treated with recombinant factor (F)VIII only or with at least one plasma-derived FVIII or FIX concentrate: results from the French haemophilia cohort.

    Science.gov (United States)

    Gaboulaud, Valérie; Parquet, Armelle; Tahiri, Cedric; Claeyssens, Ségolène; Potard, Valérie; Faradji, Albert; Peynet, Jocelyne; Costagliola, Dominique

    2002-02-01

    Human parvovirus B19 (B19) has been transmitted by some brands of virally attenuated plasma-derived factor VIII (FVIII) or IX (FIX) concentrates. To quantify the differences of human parvovirus B19 risk transmission between albumin-stabilized recombinant factor and plasma-derived factor, we studied the prevalence of IgG antibodies to B19 (anti-B19) in 193 haemophiliac children between 1 and 6-years of age who had previously been treated with albumin-stabilized recombinant FVIII only (n = 104), and in children previously treated with solvent/detergent high-purity non-immunopurified and non-nanofiltered FVIII or IX concentrates (n = 89). Association between the prevalence of anti-B19 and the treatment group was analysed using multivariate logistic regression. Age, severity and type of haemophilia, number of cumulative days of exposure to factor VIII or IX, previous history of red blood cells or plasma transfusion were considered as potential confounding variables. A higher prevalence of anti-B19 was found in children previously treated with solvent/detergent high-purity non-immunopurified and non-nanofiltered FVIII or IX concentrates than in children treated with albumin- stabilized recombinant FVIII only (OR: 22.3; CI: 7.9-62.8), independently of the other factors studied.

  8. Polyphenol-Retaining Decaffeinated Cocoa Powder Obtained by Supercritical Carbon Dioxide Extraction and Its Antioxidant Activity.

    Science.gov (United States)

    Kobori, Kinji; Maruta, Yuto; Mineo, Shigeru; Shigematsu, Toru; Hirayama, Masao

    2013-10-14

    Cocoa beans contain many functional ingredients such as theobromine and polyphenols, but also contain a relatively high amount of caffeine, which can negatively impact human health. It is therefore desirable to reduce caffeine levels in cocoa powder used to make chocolate or cocoa beverages while retaining functional ingredients. We have established conditions for supercritical carbon dioxide (SCCO₂) extraction that remove 80.1% of the caffeine from cocoa powder while retaining theobromine (94.1%) and polyphenols (84.7%). The antioxidant activity of the decaffeinated cocoa powder (DCP) made with this optimized SCCO₂ extraction method was 85.3% that of non-processed cocoa powder. The total procyanidin and total polyphenol concentrations of the DCPs resulting from various SCCO₂ extractions showed a significant positive correlation with oxygen radical absorbance capacity (ORAC). The correlation coefficient between total polyphenols and ORAC was higher than that between total procyanidins and ORAC; thus, the concentration of total polyphenols might be a greater factor in the antioxidant activity of DCP. These results indicate that we could remove large quantities of caffeine from conventional high-cocoa products while retaining the functional benefits of high polyphenol content. This SCCO₂ extraction method is expected to be applicable high-cocoa products, such as dark chocolate.

  9. Polyphenol-Retaining Decaffeinated Cocoa Powder Obtained by Supercritical Carbon Dioxide Extraction and Its Antioxidant Activity

    Directory of Open Access Journals (Sweden)

    Kinji Kobori

    2013-10-01

    Full Text Available Cocoa beans contain many functional ingredients such as theobromine and polyphenols, but also contain a relatively high amount of caffeine, which can negatively impact human health. It is therefore desirable to reduce caffeine levels in cocoa powder used to make chocolate or cocoa beverages while retaining functional ingredients. We have established conditions for supercritical carbon dioxide (SCCO2 extraction that remove 80.1% of the caffeine from cocoa powder while retaining theobromine (94.1% and polyphenols (84.7%. The antioxidant activity of the decaffeinated cocoa powder (DCP made with this optimized SCCO2 extraction method was 85.3% that of non-processed cocoa powder. The total procyanidin and total polyphenol concentrations of the DCPs resulting from various SCCO2 extractions showed a significant positive correlation with oxygen radical absorbance capacity (ORAC. The correlation coefficient between total polyphenols and ORAC was higher than that between total procyanidins and ORAC; thus, the concentration of total polyphenols might be a greater factor in the antioxidant activity of DCP. These results indicate that we could remove large quantities of caffeine from conventional high-cocoa products while retaining the functional benefits of high polyphenol content. This SCCO2 extraction method is expected to be applicable high-cocoa products, such as dark chocolate.

  10. Comparação de parâmetros periodontais após utilização de contenção convencional 3x3 plana e contenção modificada Comparison of periodontal indexes after the use of conventional 3X3 plain retainer and modified retainer

    Directory of Open Access Journals (Sweden)

    Bianca Keiko Shirasu

    2007-02-01

    Full Text Available OBJETIVO: o presente estudo teve como propósito comparar os parâmetros periodontais após a utilização de dois tipos de contenções ortodônticas fixas: contenção convencional 3x3 plana (fio ortodôntico 0,8mm retilíneo fixado apenas nos caninos contralaterais e a contenção modificada (fio ortodôntico 0,6mm com dobras permitindo o livre acesso do fio dental e fixado em todos os dentes do segmento anterior. METODOLOGIA: quinze voluntários primeiramente utilizaram a contenção convencional por seis meses. Após um intervalo de quinze dias, foi instalada a contenção modificada, utilizada pelo mesmo período de tempo. Antes de cada fase os voluntários passaram por raspagem e alisamento radicular dos dentes e orientação de higiene bucal. Ao final de cada fase os seguintes parâmetros foram avaliados: índice de placa dentária, índice gengival e índice de cálculo dentário. Além disso, foi realizada a mensuração do cálculo no fio da contenção e todos os voluntários responderam a um questionário sobre a utilização, aceitação e conforto dos dois tipos de contenções. RESULTADOS E CONCLUSÕES: foi observado que o índice de placa e o índice gengival foram maiores para a contenção modificada (pAIM: the purpose of the present study was to compare periodontal indexes after the use of two types of bonded fixed retainers: conventional 3x3 plain retainer (orthodontic wire 0.8mm, bonded to the canine teeth only and the modified retainer (0.6mm multi strand wire, allowing free access to dental floss and bonded to all anterior teeth. METHODS: a test group of fifteen patients used the conventional retainer for 6 months. After a two week interval, the modified retainer was used for another 6 months. Previous to each phase, the patients went through tooth scaling, root planing and oral hygiene orientation. At the end of each phase the dental plaque index, gingival index and dental calculus index were evaluated. Furthermore, the

  11. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false How long does the laboratory retain specimens after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How...

  12. 31 CFR 103.33 - Records to be made and retained by financial institutions.

    Science.gov (United States)

    2010-07-01

    ... financial institutions. 103.33 Section 103.33 Money and Finance: Treasury Regulations Relating to Money and... Maintained § 103.33 Records to be made and retained by financial institutions. Each financial institution... each advice, request, or instruction given to another financial institution or other person located...

  13. Assessing the feasibility of yttria-stabilized zirconia in novel designs as mandibular anterior fixed lingual retention following orthodontic treatment

    Science.gov (United States)

    Stout, Matthew

    The purpose of this study is to explore the feasibility of yttria-stabilized zirconia (Y-TZP) in fixed lingual retention as an alternative to stainless steel. Exploratory Y-TZP specimens were milled to establish design parameters. Next, specimens were milled according to ASTM standard C1161-13 and subjected to four-point flexural test to determine materials properties. Finite Element (FE) Analysis was employed to evaluate nine novel cross-sectional designs and compared to stainless steel wire. Each design was analyzed under the loading conditions to determine von Mises and bond stress. The most promising design was fabricated to assess accuracy and precision of current CAD/CAM milling technology. The superior design had a 1.0 x 0.5 mm semi-elliptical cross section and was shown to be fabricated reliably. Overall, the milling indicated a maximum percent standard deviation of 9.3 and maximum percent error of 13.5 with a cost of $30 per specimen. Y-TZP can be reliably milled to dimensions comparable to currently available metallic retainer wires. Further research is necessary to determine the success of bonding protocol and clinical longevity of Y-TZP fixed retainers. Advanced technology is necessary to connect the intraoral scan to an aesthetic and patient-specific Y-TZP fixed retainer.

  14. Crew change : attracting and retaining the next generation to the oilfield

    Energy Technology Data Exchange (ETDEWEB)

    Durocher, C. [Schlumberger Canada Ltd., Calgary, AB (Canada)

    2006-07-01

    Demand for petroleum products is expected to keep growing. However, the majority of oil and gas personnel are over 45 years old, and there are currently insufficient personnel between the ages of 25 and 45. Oil and gas operators are now examining ways of attracting and retaining skilled employees. This presentation suggested that the petroleum industry must act now to change public perceptions about the industry as well as invest in education initiatives. Enhanced relationships with schools, colleges and universities were recommended. Within the industry, career development programs, intensive technical and safety training and knowledge sharing programs were recommended. A diversification of the workforce was advised. By not encouraging women to work in the petroleum industry, the oil and gas sector is effectively ignoring 50 per cent of their potential future workforce. It was noted that employees are more likely to quit their jobs if they do not like their employer. It was also noted that steps to improve energy efficiency may provide solutions to some staff shortages. It was concluded that the petroleum industry must commit to diversity, create the right workplace environment, and develop good relationships with educational facilities in order to attract and retain skilled employees. refs., tabs., figs.

  15. [Fingertip replantation with anastomosis of palm vein and retaining the nail].

    Science.gov (United States)

    Wang, Xiang; Zhang, Wei-Kai; Yin, Shao-Meng; Wang, Hai-Bing; He, Tao; Gong, Yong-Qing; Zhu, Guo-Ming; Mao, Gen-Lian; Hu, Ming-Xing; Li, Jian

    2013-08-01

    To study the replantation methods and clinical results of amputated fingertip. From October 2007 to June 2011, 18 fingers of 13 cases were replanted with anastomosis of palm vein and retaining the nail, including 9 males and 4 females,with an average age of 26 years old ranging from 17 to 45 years old. The time from injury to therapy was from 30 min to 5 h, time of broken finger ischemia was from 1.5 to 7 h. All broken fingers were preservation under normal temperature. All fingers were survived, no vascular crisis happened. All cases were followed up from 3 to 24 months with an average of 14 months. The length and shape of replanted fingers were similar to that of the healthy side. The new nails were smooth, the function was perfect,the sense of pain and touched sensation had been recovered. Their two-piont discriminations ranged from 3 to 6 mm with an average of 5 mm. According to the assessment standard of Chinese Medical Association of Hand Surgery, the results were excellent in 14 cases, good in 3 cases, poor in 1 case. Fingertip replantation with anastomosis of palm vein and retaining the nail is regained satisfactory appearance and function of the digits with a high survival rate.

  16. Obtention of hydrogels for use as water retainers in soil by gamma irradiation

    International Nuclear Information System (INIS)

    Burillo, G.; Ogawa, T.

    1981-01-01

    We have been studying for some time the radiation induced gelation of aqueous polyacrylamide solutions in order to clarify the relationships between the gel structure and gelation conditions. The application of hydrogels as water retainers has been reported previously by some workers and there exist some commercially produced hydrogels in the market, but their costs are not yet satisfactory for use on a large scale in the agricultural region in northern Mexico, where scarcity of water is always the serious problem. In this work, with an aim of obtaining hydrogels most economically, acrylamide, polyethylene oxide, and mixtures of water soluble polymers with acrylamide monomer, were irradiated in solid state under various conditions, in order to find the optimum conditions for gelation and to obtain the hydrogels most suitable as water retainers in soil. The relationships between the gelation, amount of water in the starting materials, molecular weights of polymers, effects of additives and the dose rates, were studied. (author)

  17. Number of retained radiopaque markers on a colonic transit study does not correlate with symptom severity or quality of life in chronic constipation.

    Science.gov (United States)

    Staller, K; Barshop, K; Ananthakrishnan, A N; Kuo, B

    2018-05-01

    Ingestion of radiopaque markers (ROM) is frequently used to determine colonic transit in chronic constipation. Although ≥20% of retained markers at 5 days defines slow-transit constipation, some clinicians use the number of retained markers to determine disease severity. We assembled a cross-sectional cohort of patients presenting for evaluation of chronic constipation who underwent transit testing by ROM and completed validated symptom severity and quality-of-life (QOL) measures. We performed a correlation analysis to determine whether there was an association between number of retained markers and symptom severity and QOL. Among 159 patients undergoing evaluation for chronic constipation, there was poor correlation between the number of retained markers and symptom severity (R = .09, P = .25) and QOL. Among the 55 patients with slow-transit constipation defined by ≥5 retained markers retained on day 5, there were similarly poor correlations between symptom severity (R = .17, P = .21) and QOL (R = .07, P = .60). Excluding patients with irritable bowel syndrome and outlet obstruction by balloon expulsion testing did not materially alter our results, nor did a multivariable analysis controlling for demographic and psychiatric confounders. Among patients with chronic constipation, number of retained markers on a ROM colonic transit study does not correlate with measures of symptom severity or QOL. Clinicians should be cautious about overinterpreting ROM transit testing. © 2017 John Wiley & Sons Ltd.

  18. Crystallography of lath martensite and stabilization of retained austenite

    International Nuclear Information System (INIS)

    Sarikaya, M.

    1982-10-01

    TEM was used to study the morphology and crystallography of lath martensite in low and medium carbon steels in the as-quenched and 200 0 C tempered conditions. The steels have microduplex structures of dislocated lath martensite and continuous thin films of retained austenite at the lath interfaces. Stacks of laths form the packets which are derived from different [111] variants of the same austenite grain. The residual parent austenite enables microdiffraction experiments with small electron beam spot sizes for the orientation relationships (OR) between austenite and martensite. All three most commonly observed ORs, namely Kurdjumov-Sachs, Nishiyama-Wassermann, and Greninger-Troiano, operate within the same sample

  19. Crystallography of lath martensite and stabilization of retained austenite

    Energy Technology Data Exchange (ETDEWEB)

    Sarikaya. M.

    1982-10-01

    TEM was used to study the morphology and crystallography of lath martensite in low and medium carbon steels in the as-quenched and 200/sup 0/C tempered conditions. The steels have microduplex structures of dislocated lath martensite and continuous thin films of retained austenite at the lath interfaces. Stacks of laths form the packets which are derived from different (111) variants of the same austenite grain. The residual parent austenite enables microdiffraction experiments with small electron beam spot sizes for the orientation relationships (OR) between austenite and martensite. All three most commonly observed ORs, namely Kurdjumov-Sachs, Nishiyama-Wassermann, and Greninger-Troiano, operate within the same sample.

  20. A new skeletal retention system for retaining anterior open bites

    Directory of Open Access Journals (Sweden)

    Bodore Albaker

    2013-01-01

    Full Text Available Objectives: Relapse of anterior open bite after treatment poses a challenge to orthodontists and warrants finding new methods. We aimed to compare the effect of a skeletal retention (SR system to the conventional retention (CR commonly used. Materials and Methods: Twenty patients participated in this study. SR group ten patients (five females and five males with mean age of 16.2 years, CR group ten patients (five females and five males with mean age of 17.1 years in pretreatment stage. The SR system is comprised of four self-drilling miniscrews and vacuum retainers with interarch elastics where the CR group is comprised of removable or fixed retainers. Pretreatment (T1, posttreatment (T2, and 1-year follow up (T3 lateral cephalograms were taken and analyzed to compare the stability of both retention modalities. Results: The overbite in the CR group showed more relapse in the form of significant reduction when compared to the SR group (P < 0.001. The overbite was reduced only by 0.1 mm (±0.3 in the SR group compared to 1.4 mm (±0.9 in the CR group. In the CR group, the upper incisors and first molar showed a more significant relapse compared to the SR group (P < 0.05. Conclusion: Skeletal retention using miniscrews and vertical elastic is an effective method for retention of anterior open bite cases.

  1. Talent management : Retaining and managing technical specialists in a technical career

    OpenAIRE

    Brunila, Alexandra; Baedecke Yllner, Emelie

    2013-01-01

    The purpose of this thesis is to investigate talent management and how companies should work with talent management in order to retain and manage technical specialists in a technical career. Talent management is found to be important for modern organizations because of the advent of the knowledge economy, new generations entering the workforce and the need for businesses to become more strategic and competitive, which implies new ways of managing human capital. Furthermore, talent management ...

  2. Retaining Residual Ovarian Tissue following Ovarian Failure Has Limited Influence on Bone Loss in Aged Mice

    Directory of Open Access Journals (Sweden)

    Zelieann R. Craig

    2010-01-01

    Full Text Available Previous work showed that retaining residual ovarian tissue protects young mice from accelerated bone loss following ovarian failure. The present study was designed to determine whether this protection is also present in aged animals. Aged (9–12 months C57BL/6Hsd female mice were divided into: CON (vehicle, VCD (160 mg/kg; 15d, or OVX (ovariectomized. Lumbar BMD was monitored by DXA and μCT used to assess vertebral microarchitecture. BMD was not different between VCD and CON at any time point but was lower (P<.05 than baseline, starting 1 month after ovarian failure in VCD and OVX mice. Following μCT analysis there were no differences between CON and VCD, but OVX mice had lower bone volume fraction, trabecular thickness, and a trend for decreased connectivity density. These findings provide evidence that retention of residual ovarian tissue may protect aged follicle-depleted mice from accelerated bone loss to a lesser extent than that observed in young mice.

  3. Patient satisfaction survey of mandibular two-implant-retained overdentures in a predoctoral program.

    Science.gov (United States)

    Dias, Renata; Moghadam, Marjan; Kuyinu, Esther; Jahangiri, Leila

    2013-08-01

    In response to the Commission of Dental Accreditation (CODA) mandate of a competency in the "replacement of teeth including fixed, removable and implant" prostheses, a predoctoral implant curriculum was implemented at New York University College of Dentistry. The assessment of the success or failure of a program should include an assessment of patient satisfaction with the treatment received in the predoctoral clinics. The purpose of this study was to measure patient satisfaction with the mandibular 2-implant-retained overdenture therapy received in the predoctoral program at New York University College of Dentistry. A telephone survey of patients who received an implant-retained overdenture in the predoctoral clinics at New York University, College of Dentistry (n=101) was conducted. Two of the authors contacted patients for participation in the survey and, using a prepared script, asked about their satisfaction with items such as function, comfort, and esthetics in addition to their overall satisfaction with the treatment they received. Data were analyzed with descriptive statistics. The study revealed that 79% of participants were satisfied with their masticatory ability, 84% were satisfied with the comfort of the prosthesis, and 89% were satisfied with the esthetics of their new prosthesis. Additionally, 85% of participants reported satisfaction with the overall treatment experience, and 90% would recommend that a friend receive the same treatment. The results of this study support the incorporation of treatment with an implant-retained mandibular overdenture as part of the routine care provided in the predoctoral education program to meet the mandates of CODA. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  4. The Effect of Cash Dividend, Retained Earnings, and Stock Price of Manufacturing Company Listed In Indonesia Stock Exchange

    OpenAIRE

    Farah Margaretha

    2015-01-01

    This study aims to determine the effect of cash dividends per share, retained earnings per share, earnings per share, and leverage on the stock price of manufacture industry in Indonesia from 2008-2012. Research used secondary data in which the source was obtained indirectly through an intermediary medium or data processed from literatures and reports associated with this research. Independent variables in this study (x) are cash dividends per share, retained earnings per share, earnings per ...

  5. A Conjunctival Mass in the Deep Superior Fornix After a Long Retained Hard Contact Lens in a Patient With Keloids

    NARCIS (Netherlands)

    Zola, Enrica; van der Meulen, Ivanka J. E.; Lapid-Gortzak, Ruth; van Vliet, J. Mj; Nieuwendaal, Carla P.

    2008-01-01

    Purpose: To report a case of an upper eyelid mass induced by a rigid contact lens retained for more than 3 years in the eye of a patient with a general history of keloids and to provide a review of the literature on retained contact lenses. Methods: Case report. Results: A 45-year-old woman with an

  6. Westinghouse AP1000 advanced passive plant: design features and benefits

    International Nuclear Information System (INIS)

    Walls, S.J.; Cummins, W.E.

    2003-01-01

    The Westinghouse AP1000 Program is aimed at implementing the AP1000 plant to provide a further major improvement in plant economics while maintaining the passive safety advantages established by the AP600. An objective is to retain to the maximum extent possible the plant design of the AP600 so as to retain the licensing basis, cost estimate, construction schedule, modularization scheme, and the detailed design from the AP600 program. Westinghouse and the US Nuclear Regulatory Commission staff have embarked on a program to complete Design Certification for the AP1000 by 2004. A pre-certification review phase was completed in March 2002 and was successful in establishing the applicability of the AP600 test program and AP600 safety analysis codes to the AP1000 Design Certification. On March 28, 2002, Westinghouse submitted to US NRC the AP1000 Design Control Document and Probabilistic Risk Assessment, thereby initiating the formal design certification review process. The results presented in these documents verify the safety performance of the API 000 and conformance with US NRC licensing requirements. Plans are being developed for implementation of a series of AP1000 plants in the US. Key factors in this planning are the economics of AP1000, and the associated business model for licensing, constructing and operating these new plants. Similarly plans are being developed to get the AP1000 design reviewed for use in the UK. Part of this planning has been to examine the AP1000 design relative to anticipated UK safety and licensing issues. (author)

  7. Recruiting and retaining high-quality teachers in rural areas.

    Science.gov (United States)

    Monk, David H

    2007-01-01

    In examining recruitment and retention of teachers in rural areas, David Monk begins by noting the numerous possible characteristics of rural communities--small size, sparse settlement, distance from population concentrations, and an economic reliance on agricultural industries that are increasingly using seasonal and immigrant workers to minimize labor costs. Many, though not all, rural areas, he says, are seriously impoverished. Classes in rural schools are relatively small, and teachers tend to report satisfaction with their work environments and relatively few problems with discipline. But teacher turnover is often high, and hiring can be difficult. Monk observes that rural schools have a below-average share of highly trained teachers. Compensation in rural schools tends to be low, perhaps because of a lower fiscal capacity in rural areas, thus complicating efforts to attract and retain teachers. Several student characteristics, including relatively large shares of students with special needs and with limited English skills and lower shares of students attending college, can also make it difficult to recruit and retain high-quality teachers. Other challenges include meeting the needs of highly mobile children of low-income migrant farm workers. With respect to public policy, Monk asserts a need to focus on a subcategory of what might be called hard-to-staff rural schools rather than to develop a blanket set of policies for all rural schools. In particular, he recommends a focus on such indicators as low teacher qualifications, teaching in fields far removed from the area of training, difficulty in hiring, high turnover, a lack of diversity among teachers in the school, and the presence of migrant farm workers' children. Successful efforts to stimulate economic growth in these areas would be highly beneficial. He also calls attention to the potential for modern telecommunication and computing technologies to offset some of the drawbacks associated with teaching

  8. 17 CFR 229.1009 - (Item 1009) Persons/assets, retained, employed, compensated or used.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 2 2010-04-01 2010-04-01 false (Item 1009) Persons/assets, retained, employed, compensated or used. 229.1009 Section 229.1009 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD INSTRUCTIONS FOR FILING FORMS UNDER SECURITIES ACT OF 1933, SECURITIES EXCHANGE ACT OF 1934 AND ENERGY...

  9. The effect of tempering on mechanical properties of 50Mn18Cr4WN retaining ring material

    International Nuclear Information System (INIS)

    Sun, M.C.; Guo, C.H.; Zheng, Z.Z.; Ma, Z.M.

    1990-01-01

    50Mn18Cr4WN is a retaining ring steel. It is strengthened by solution heat treatment and cold working. The process produces high macro residual stress. The retaining ring must be tempered for stress-relief. When the ring is sleeved, it is heated too. If the retaining ring is tempered, are the mechanical properties of the retaining ring damaged? The problem is described in the article. The tempering of testing pieces was carried out at several temperatures: 350degC, 400degC, 450degC, 500degC and 650degC. The tempering time was 3h. The yield point, tensile strength, elongation and reduction of area were determined by means of the tensile test. In the results, for temperatures between 350degC and 450degC, the yield point, tensile strength, elongation and reduction of area did not change notably. A stress corrosion cracking test was also carried out in a 3%Ni 4 NO 3 , 36%Ca(NO 3 ) 2 aqueous solution. K 1scc values after tempering at 450degC and without tempering were measured. The results showed that the K 1scc after tempering at 450degC decreased notably. Micrographs show that carbo-nitride precipitated. The precipitated carbo-nitride particles increased in size at the grain boundaries. The precipitated carbonitride particles increased in number at slip lines. It is clear that the precipitated particles lead to the increase of micro-cells and the micro-cells aggravated the stress corrosion cracking process. (orig.)

  10. On the importance of retaining stresses and strains in repositioning computational biomechanical models of the cervical spine.

    Science.gov (United States)

    Boakye-Yiadom, Solomon; Cronin, Duane S

    2018-01-01

    Human body models are created in a specific posture and often repositioned and analyzed without retaining stresses that result from repositioning. For example, repositioning a human neck model within the physiological range of motion to a head-turned posture prior to an impact results in initial stresses within the tissues distracted from their neutral position. The aim of this study was to investigate the effect of repositioning on the subsequent kinetics, kinematics, and failure modes, of a lower cervical spine motion segment, to support future research at the full neck level. Repositioning was investigated for 3 modes (tension, flexion, and extension) and 3 load cases. The model was repositioned and loaded to failure in one continuous load history (case 1), or repositioned then restarted with retained stresses and loaded to failure (case 2). In case 3, the model was repositioned and then restarted in a stress-free state, representing current repositioning methods. Not retaining the repositioning stresses and strains resulted in different kinetics, kinematics, or failure modes, depending on the mode of loading. For the motion segment model, the differences were associated with the intervertebral disc fiber reorientation and load distribution, because the disc underwent the largest deformation during repositioning. This study demonstrated that repositioning led to altered response and tissue failure, which is critical for computational models intended to predict injury at the tissue level. It is recommended that stresses and strains be included and retained for subsequent analysis when repositioning a human computational neck model. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Sustaining U.S. Nuclear Submarine Design Capabilities

    Science.gov (United States)

    2007-01-01

    million annually in the NSWC’s Card- erock Division submarine design workforce in excess of reimburs - able demand to sustain skills that might...large testing infrastructure. Conse- quently, the Navy retains management and operation of these facili- ties under direct reimbursement from private...the water. 4 These facilities are maintained within the naval warfare centers, which, as working capi- tal organizations, require reimbursement from

  12. Recruiting and retaining low-income Latinos in psychotherapy research.

    Science.gov (United States)

    Miranda, J; Azocar, F; Organista, K C; Muñoz, R F; Lieberman, A

    1996-10-01

    This article offers suggestions for recruiting and retaining low-income Latinos in treatment studies. Because Latinos underuse traditional mental health services, places such as medical centers or churches with large Latino constituents are suggested as useful alternative sources. To keep Latinos in research protocols, providing culturally sensitive treatments are necessary. Culturally sensitive treatments should incorporate families as part of recruitment efforts, particularly older men in the family. In addition, showing respect is an important aspect of traditional Latino culture that includes using formal titles and taking time to listen carefully. Finally, traditional Latinos tend to like interactions with others that are more warm and personal than is generally part of a research atmosphere.

  13. Incentives for retaining and motivating health workers in Pacific and Asian countries

    Directory of Open Access Journals (Sweden)

    Tulloch Jim

    2008-09-01

    Full Text Available Abstract This paper was initiated by the Australian Agency for International Development (AusAID after identifying the need for an in-depth synthesis and analysis of available literature and information on incentives for retaining health workers in the Asia-Pacific region. The objectives of this paper are to: 1. Highlight the situation of health workers in Pacific and Asian countries to gain a better understanding of the contributing factors to health worker motivation, dissatisfaction and migration. 2. Examine the regional and global evidence on initiatives to retain a competent and motivated health workforce, especially in rural and remote areas. 3. Suggest ways to address the shortages of health workers in Pacific and Asian countries by using incentives. The review draws on literature and information gathered through a targeted search of websites and databases. Additional reports were gathered through AusAID country offices, UN agencies, and non-government organizations. The severe shortage of health workers in Pacific and Asian countries is a critical issue that must be addressed through policy, planning and implementation of innovative strategies – such as incentives – for retaining and motivating health workers. While economic factors play a significant role in the decisions of workers to remain in the health sector, evidence demonstrates that they are not the only factors. Research findings from the Asia-Pacific region indicate that salaries and benefits, together with working conditions, supervision and management, and education and training opportunities are important. The literature highlights the importance of packaging financial and non-financial incentives. Each country facing shortages of health workers needs to identify the underlying reasons for the shortages, determine what motivates health workers to remain in the health sector, and evaluate the incentives required for maintaining a competent and motivated health workforce

  14. Complications and Clinical Considerations of the Implant-Retained Zirconia Complete-Arch Prosthesis with Various Opposing Dentitions.

    Science.gov (United States)

    Gonzalez, Jorge; Triplett, Robert G

    To evaluate the performance of the implant-retained zirconia complete-arch prosthesis with various opposing dentitions. The 40 patients included in this retrospective case series study were treated with one or two implant-retained zirconia complete-arch prostheses (ZIRCAP) using the Zirkonzahn protocol. Prettau zirconia frames were created with strategic cutbacks in the structure to extend zirconia incisal coverage of the esthetic anterior sextants and complete monolithic zirconia in the molar areas; subsequent layers of porcelain were applied to nonfunctional and esthetic areas. Patients had three possible occlusal scenarios: (1) maxillary ZIRCAP and mandibular ZIRCAP, (2) maxillary ZIRCAP and mandibular natural dentition, and (3) maxillary ZIRCAP and mandibular conventional hybrid prosthesis. Complications were recorded during follow-up appointments 3, 6, and 12 months after definitive prosthesis delivery. The mean treatment observation period was 33 months. Eight prosthetic complications were noted for the 40 implant-retained zirconia complete-arch prostheses (18.18%), including six cases of minor porcelain chipping and two cases of debonding of the metal insert from the zirconia framework. Maxillary ZIRCAP opposing mandibular ZIRCAP and maxillary ZIRCAP opposing mandibular natural dentition occlusal scenarios presented the same complication ratio of 4. No complications were seen in the maxillary ZIRCAP opposing mandibular conventional hybrid prosthesis group, yet 16 complications were found as denture tooth fractures in 12 mandibular conventional hybrid prostheses (ratio of 0.75). The results indicate that the implant-retained zirconia complete-arch prosthesis offers acceptable performance for use as an alternative to the conventional titanium framework acrylic veneer prosthesis for complete edentulism with a lower incidence of prosthetic complications and fewer maintenance appointments. Chipping of veneering porcelain was the most common complication, but a

  15. Proximal balloon deflation technique: a novel method to retrieve retained or entrapped equipment from the coronary system.

    Science.gov (United States)

    Ashikaga, Takashi; Inagaki, Hiroshi; Satoh, Yasuhiro; Isobe, Mitsuaki

    2012-01-01

    Complications of retained or entrapped equipment in the coronary system are still encountered during angioplasty procedures. Although these complications are rare, it is extremely difficult to retrieve such equipments. We report on two cases that a retained IVUS catheter or an entrapped filter wire were retrieved from the coronary system using more simplified technique that does not involve in the usage of snare or any other retrieval tool. After placing an additional guidewire and balloon alongside an equipment, it was easily retrieved from the coronary system just after the proximal balloon deflation. Copyright © 2012. Published by Elsevier Inc.

  16. Effects of retained austenite and hydrogen on the rolling contact fatigue behaviours of carbide-free bainitic steel

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Chunlei; Dan, Rui [State Key Laboratory of Metastable Materials Science and Technology, College of Materials Science and Engineering, Yanshan University, Qinhuangdao 066004 (China); Zhang, Fucheng, E-mail: zfc@ysu.edu.cn [State Key Laboratory of Metastable Materials Science and Technology, College of Materials Science and Engineering, Yanshan University, Qinhuangdao 066004 (China); Lv, Bo [School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004 (China); Yan, Zhigang; Shan, Jun; Long, Xiaoyan [State Key Laboratory of Metastable Materials Science and Technology, College of Materials Science and Engineering, Yanshan University, Qinhuangdao 066004 (China)

    2014-01-31

    The effects of retained austenite and hydrogen on the rolling contact fatigue (RCF) behaviours of a new carbide-free bainitic steel (CFBS) were studied by means of the RCF testing, electrolytic hydrogen charging, transmission electron microscope (TEM), scanning electron microscope (SEM) and X-ray diffraction (XRD). The results showed that the new carbide-free bainitic steels (CFBSs) exhibited very good RCF performance under the high contact stress of 1.7 GPa, and pitting and spalling were the main mode of the RCF failure. The RCF performance of the new CFBS was improved by the retained austenite content increasing, while obviously decreased by hydrogen.

  17. Instrumental and sensory quantification of oral coatings retained after swallowing semi-solid foods

    NARCIS (Netherlands)

    Prinz, J.F.; Huntjens, L.; Wijk, de R.A.

    2006-01-01

    After a mouthful of food has been swallowed, some food material is always retained in the mouth. With semi-solid foods this is in the form of a coating that adheres to the oral mucosa. The amount and location of this material may play an important role in food sensations. In this study two

  18. Thermal and mechanical stability of retained austenite in aluminum-containing multiphase TRIP steels

    CERN Document Server

    Zwaag, S; Kruijver, S O; Sietsma, J

    2002-01-01

    Stability of retained austenite is the key issue to understand transformation-induced plasticity (TRIP) effect. In this work, both thermal stability and mechanical stability are investigated by thermo-magnetic as well as in situ conventional X-ray diffraction and micro synchrotron radiation diffraction measurements. The thermal stability in a 0.20C-1.52Mn-0.25Si-0.96Al (wt%) TRIP steel is studied in the temperature range between 5 and 300 K under a constant magnetic field of 5T. It is found that almost all austenite transforms thermally to martensite upon cooling to 5K and M sub s and M sub f temperatures are analyzed to be 355 and 115 K. Transformation kinetics on the fraction versus temperature relation are well described by a model based on thermodynamics. From the in situ conventional X-ray and synchrotron diffraction measurements in a 0.17C-1.46Mn-0.26Si-1.81Al (wt%) steel, the volume fraction of retained austenite is found to decrease as the strain increases according to Ludwigson and Berger relation. T...

  19. Six-year clinical outcome of single implant-retained mandibular overdentures--a pilot study.

    Science.gov (United States)

    Passia, Nicole; Wolfart, Stefan; Kern, Matthias

    2015-10-01

    The aim of this prospective pilot study was to evaluate the prosthodontic maintenance as well as the implant outcome of single implant-retained mandibular overdentures over an observation period of 6 years. Eleven edentulous patients received one single implant in the midline of the mandible. Denture bases were temporarily relined and 2 months later provided with a ball attachment for implant retention. Implant related parameters and prosthodontic maintenance interventions were assessed 4 weeks after implant loading and then once a year. Over a mean observation period of 75.9 months, no implant was lost. The most frequent prosthetic maintenance intervention was activation of the matrix due to loss of retention, followed by exchange of the female part. Eight denture bases had to be repaired after a fracture in the midline area. Within the limitations of this preliminary clinical study, the concept of a single midline implant to retain a mandibular complete denture was a successful treatment option for elderly edentulous patients. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Removal of retained biliary concretions through the T-tube track

    International Nuclear Information System (INIS)

    Daehnert, W.; Guenther, R.; Schmidt, H.D.; Staritz, M.; Thelen, M.; Mainz Univ.

    1984-01-01

    Within seven years 23 patients were treated postoperatively by percutaneous bile stone extraction. This procedure was successful in 18 patients. Although an interval of 5-7 weeks between choledochotomy and percutaneous extraction is recommended, the procedure was done 11 to 31 days after surgery with no negative effects. In six cases the stones had to be dislodged into a more favorable position with a Fogarty-type balloon catheter. The papilla of Vater was dilated in two cases. With the development of newer techniques trans-T-tube extraction remains the treatment of choice in retained intra- and extrahepatic bile duct stones. (orig.) [de

  1. Biofilm formation on stainless steel and gold wires for bonded retainers in vitro and in vivo and their susceptibility to oral antimicrobials

    NARCIS (Netherlands)

    Jongsma, Marije A.; Pelser, Floris D. H.; van der Mei, Henny C.; Atema-Smit, Jelly; van de Belt-Gritter, Betsy; Busscher, Henk J.; Ren, Yijin

    OBJECTIVE: Bonded retainers are used in orthodontics to maintain treatment result. Retention wires are prone to biofilm formation and cause gingival recession, bleeding on probing and increased pocket depths near bonded retainers. In this study, we compare in vitro and in vivo biofilm formation on

  2. Forms of newly retained phosphorus in mineral soils

    Directory of Open Access Journals (Sweden)

    Armi Kaila

    1964-01-01

    Full Text Available The distribution of soluble phosphate in various fractions of soil phosphorus was studied by treating 1 g-samples of 180 mineral soils with 50 ml of a KH2PO4- solution containing P 5 mg/l for 24 hours, and carrying out the fractionation by the method of CHANG and JACKSON after the solution was removed and the moist samples had stood for 3 days at room temperature. The amount of retained phosphorus in the different fractions was computed by taking the difference between the treated and check samples. In the 70 samples of clay soils, the mean proportion of the retained phosphorus was 57 per cent of the 250 mg/kg applied, in the 62 samples of the sand and fine sand soils the corresponding part was 45 per cent, and in the 48 samples of loam and silt soils it was 44 per cent. The higher retention in the clay soils was mainly due to a higher retention in the alkali-soluble fraction. The net increase in the fluoride-soluble forms was of the same order in these three soil groups. On the average, more than 95 per cent of the sorbed phosphorus was found in the fluoride-soluble and alkali-soluble fractions. In one third of the samples a low net increase in the acid soluble fraction was detected, but this may be partly due to changes in the solubility of the native phosphorus in the treated samples. Owing to the fairly large variation, the tendency to somewhat higher mean values for the sorption in the subsoils compared with those of the topsoils was not statistically significant. The ratio between the sorbed amounts of fluoride-soluble and alkali soluble forms was higher in the sand and fine sand soils than in the clay soils. Only in 15 samples, most of them Litorina-soils, the net increase in the alkali-soluble forms was higher than in the fluoride-soluble fraction. Probably, because an equilibrium in the phosphorus conditions was not yet reached at the end of the treatment, the attempt failed to find any clear connection between the distribution of the

  3. Design and Analysis of a Permanent Magnet Generator for Naval Applications

    Science.gov (United States)

    2005-06-01

    Miller, Design of Brushless Permanent Magnet Motors , Magna Physics Publishing and Clarendon Press, 1994. [19] James L. Kirtley, "Course 6.685: Electric...Kirtley & Edward C. Lovelace, "Drag Loss in Retaining Rings of Permanent Magnet Motors ," SatCon Technology Corporation, March, 2003. [66] H. Polinder

  4. Seed-borne viruses detected on farm-retained seeds from smallholder farmers in Zimbabwe, Burkina Faso, Bangladesh and Vietnam

    DEFF Research Database (Denmark)

    Manyangarirwa, W.; Sibiya, J.; Mortensen, C A Nieves Paulino

    2010-01-01

    The smallholder farming sector in much of the developing world relies on the use of farm-retained seed. The availability of good quality disease free seed is important in enhancing food security but seed-borne viruses can be a major problem on farm-retained seed. Seeds of tomato (Lycopersicon...... electron microscopy, Enzyme Linked Immunosorbent Assay (ELISA) and biological assays. Tomato mosaic virus (ToMV) was detected in 36% of tomato samples and in 8% of paprika samples using indicator Nicotiana tabacum cultivars Xanthinc and White Burley. Some 43% of cowpea samples were infected with Cowpea...

  5. Tumor-Initiating Label-Retaining Cancer Cells in Human Gastrointestinal Cancers Undergo Asymmetric Cell Division

    Science.gov (United States)

    Xin, Hong-Wu; Hari, Danielle M.; Mullinax, John E.; Ambe, Chenwi M.; Koizumi, Tomotake; Ray, Satyajit; Anderson, Andrew J.; Wiegand, Gordon W.; Garfield, Susan H.; Thorgeirsson, Snorri S.; Avital, Itzhak

    2012-01-01

    Label-retaining cells (LRCs) have been proposed to represent adult tissue stem cells. LRCs are hypothesized to result from either slow cycling or asymmetric cell division (ACD). However, the stem cell nature and whether LRC undergo ACD remain controversial. Here, we demonstrate label-retaining cancer cells (LRCCs) in several gastrointestinal (GI) cancers including fresh surgical specimens. Using a novel method for isolation of live LRCC, we demonstrate that a subpopulation of LRCC is actively dividing and exhibits stem cells and pluripotency gene expression profiles. Using real-time confocal microscopic cinematography, we show live LRCC undergoing asymmetric nonrandom chromosomal cosegregation LRC division. Importantly, LRCCs have greater tumor-initiating capacity than non-LRCCs. Based on our data and that cancers develop in tissues that harbor normal-LRC, we propose that LRCC might represent a novel population of GI stem-like cancer cells. LRCC may provide novel mechanistic insights into the biology of cancer and regenerative medicine and present novel targets for cancer treatment. PMID:22331764

  6. Meshed-Pumpkin Super-Pressure Balloon Design

    Science.gov (United States)

    Jones, Jack; Yavrouian, Andre

    2003-01-01

    An improved, lightweight design has been proposed for super-pressure balloons used to carry scientific instruments at high altitudes in the atmosphere of Earth for times as long as 100 days. [A super-pressure balloon is one in which the pressure of the buoyant gas (typically, helium) is kept somewhat above ambient pressure in order to maintain approximately constant density and thereby regulate the altitude.] The proposed design, called "meshed pumpkin," incorporates the basic concept of the pumpkin design, which is so named because of its appearance. The pumpkin design entails less weight than does a spherical design, and the meshed-pumpkin design would reduce weight further. The basic idea of the meshed-pumpkin design is to reinforce the membrane of a pumpkin balloon by attaching a strong, lightweight fabric mesh to its outer surface. The reinforcement would make it possible to reduce the membrane mass to one-third or less of that of the basic pumpkin design while retaining sufficient strength to enable the balloon to remain at approximately constant altitude for months.

  7. An expert system for reward systems design.

    OpenAIRE

    Erturk, Alper

    2000-01-01

    Approved for public release; distribution is unlimited Today's business environment is a highly competitive marketplace. In this competition, organizations distribute numerous rewards to motivate, attract and retain employees, such as pay, fringe benefits and promotions. However, not all managers have the necessary knowledge and expertise to effectively decide and structure reward systems. This thesis presents an expert system to assist managers with designing the most appropriate reward s...

  8. Analysis of the Retained Gas Sample (RGS) Extruder Assembly

    International Nuclear Information System (INIS)

    Coverdell, B.L.

    1995-09-01

    In order for the Retained Gas Sample (RGS) Extruder Assembly to be safely used it was determined by the cognizant engineer that analysis was necessary. The use of the finite-element analysis (FEA) progarm COSMOS/M version 1.71 permitted a quick, easy, and detailed stress analysis of the RGS Extruder Assembly. The FEA model is a three dimensional model using the SHELL4T element type. From the results of the FEA, the cognizant engineer determined that the RGS extruder would be rated at 10,000 lbf and load tested to 12,000 lbf. The respective input and output files for the model are EXTR02.GFM and EXTR02.OUT and can be found on the attached tape

  9. Tightening techniques for the retaining screws of universal abutment

    Directory of Open Access Journals (Sweden)

    Alexandre Wittcinski REGALIN

    Full Text Available Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control – 32 Ncm torque; H20 – holding 32 Ncm torque for 20 s; R – 32 Ncm torque, repeated after 10 min (retorque; and H20+R – combining the two tightening techniques. Titanium and coated screws were also evaluated. Result Statistical analysis showed higher maintained torque for titanium screws (p<0.001. The H20+R technique showed the highest maintained torque (p=0.003, but the H20 technique’s maintained torque was similar. Conclusion Titanium screws associating the two tightening techniques can improve maintained torque.

  10. Oral Rehabilitation with Implant-Retained Overdenture in a Patient with Down Syndrome.

    Science.gov (United States)

    Altintas, Nuray Yilmaz; Kilic, Serdar; Altintas, Subutay Han

    2017-01-24

    Down syndrome, known as trisomy 21, is the most common chromosomal disorder. The disorder affects mental and systemic development as well as oral structure, including dental anomalies, high susceptibility of periodontal disease, and poor quality of alveolar bone. This report presents a case of dental rehabilitation by means of dental implants of a patient with Down syndrome. Two titanium dental implants were placed in the maxilla, and three titanium dental implants were installed in the mandible. One implant was lost during the osseointegration period. The prosthetic rehabilitation was performed with implant-retained maxillary and mandibular overdentures with the Locator attachment system. After a 2-year follow-up period, the patient was doing well, and all implants were clinically stable with no signs of bone loss or inflammation. The present study emphasizes that implant-retained overdentures with Locator attachment system could be a therapeutic option even for patients with Down syndrome. This therapy prevents crestal bone loss around the implants, improves functional and esthetic outcomes, and provides optimum oral hygiene for patients with mild mental impairment. Careful patient selection and education of patients and caregivers are essential considerations for a successful and safe treatment with dental implants in Down syndrome patients. © 2017 by the American College of Prosthodontists.

  11. Nanomechanical properties of bone around cement-retained abutment implants. A minipig study

    Directory of Open Access Journals (Sweden)

    R.R.M. de Barros

    2016-06-01

    Full Text Available Aim The nanomechanical evaluation can provide additional information about the dental implants osseointegration process. The aim of this study was to quantify elastic modulus and hardness of bone around cemented-retained abutment implants positioned at two different crestal bone levels. Materials and methods The mandibular premolars of 7 minipigs were extracted. After 8 weeks, 8 implants were inserted in each animal: crestally on one side of the mandible and subcrestally on the other (crestal and subcrestal groups. Functional loading were immediately provided with abutments cementation and prostheses installation. Eight weeks later, the animals euthanasia was performed and nanoindentation analyses were made at the most coronal newly formed bone region (coronal group, and below in the threaded region (threaded group of histologic sections. Results The comparisons between subcrestal and crestal groups did not achieve statistical relevance; however the elastic modulus and hardness levels were statistically different in the two regions of evaluation (coronal and threaded. Conclusions The crestal and subcrestal placement of cement-retained abutment implants did not affect differently the nanomechanical properties of the surrounding bone. However the different regions of newly formed bone (coronal and threaded groups were extremely different in both elastic modulus and hardness, probably reflecting their differences in bone composition and structure.

  12. Wise retained in the endoplasmic reticulum inhibits Wnt signaling by reducing cell surface LRP6.

    Science.gov (United States)

    Guidato, Sonia; Itasaki, Nobue

    2007-10-15

    The Wnt signaling pathway is tightly regulated by extracellular and intracellular modulators. Wise was isolated as a secreted protein capable of interacting with the Wnt co-receptor LRP6. Studies in Xenopus embryos revealed that Wise either enhances or inhibits the Wnt pathway depending on the cellular context. Here we show that the cellular localization of Wise has distinct effects on the Wnt pathway readout. While secreted Wise either synergizes or inhibits the Wnt signals depending on the partner ligand, ER-retained Wise consistently blocks the Wnt pathway. ER-retained Wise reduces LRP6 on the cell surface, making cells less susceptible to the Wnt signal. This study provides a cellular mechanism for the action of Wise and introduces the modulation of cellular susceptibility to Wnt signals as a novel mechanism of the regulation of the Wnt pathway.

  13. A 26-Year-Old Retained Demised Abdominal Pregnancy Presenting with Umbilical Fistula

    Science.gov (United States)

    Daniel, Nnadi; Bashir, Bello; Ibrahim, Ango; Swati, Singh

    2014-01-01

    This is a report on a 72-year-old postmenopausal woman who presented with passage of fetal bones through an umbilical fistula. She was diagnosed as a case of demised abdominal pregnancy, which had been retained for 26 years. She subsequently had exploratory laparotomy, evacuation of the abdominal pregnancy, hysterectomy, and bowel resection. The patient's condition remained unstable throughout the postoperative period and she died from septicemia on the eleventh day. PMID:24639908

  14. A 26-Year-Old Retained Demised Abdominal Pregnancy Presenting with Umbilical Fistula

    Directory of Open Access Journals (Sweden)

    Nnadi Daniel

    2014-01-01

    Full Text Available This is a report on a 72-year-old postmenopausal woman who presented with passage of fetal bones through an umbilical fistula. She was diagnosed as a case of demised abdominal pregnancy, which had been retained for 26 years. She subsequently had exploratory laparotomy, evacuation of the abdominal pregnancy, hysterectomy, and bowel resection. The patient’s condition remained unstable throughout the postoperative period and she died from septicemia on the eleventh day.

  15. The next generation of CANDU: reactor design to meet future energy markets

    International Nuclear Information System (INIS)

    Hopwood, J.M.; Love, J.W.; Wren, D.J.

    2001-01-01

    Nuclear power plant designs for the future must respond to increasingly demanding market requirements. This means that value can be gained from substantial product development directed at these requirements. For the CANDU system, AECL has adopted the revolutionary approach, accommodating significant changes to design while retaining traditional CANDU strengths. The focus of the new design is to achieve a 40% reduction in capital cost, quicken construction time and higher efficiency. Key aspects of the new design include: light water coolant, smaller core, slightly enriched fuel, higher temperature and pressure coolant. Work is well advanced on the preliminary design

  16. Retaining of botanical diversity of steppe ecosystems at the Semipalatinsk test site area

    International Nuclear Information System (INIS)

    Sultanova, B.M.

    2005-01-01

    The nuclear tests conducted on the STS area have an effect on steppe biome. Regime of military secrecy allowed retaining extensive diversity of steppe vegetation at the area of the former Semipalatinsk test site, although the vegetation was liquidated in the most part of Kazakhstan. Unique biologic diversity of the steppe vegetation requires status of particularly secured vegetation of the STS area. (author)

  17. Microelectronics from fundamentals to applied design

    CERN Document Server

    Di Paolo Emilio, Maurizio

    2016-01-01

    This book serves as a practical guide for practicing engineers who need to design analog circuits for microelectronics.  Readers will develop a comprehensive understanding of the basic techniques of analog modern electronic circuit design, discrete and integrated, application as sensors and control and data acquisition systems,and techniques of PCB design.  ·         Describes fundamentals of microelectronics design in an accessible manner; ·         Takes a problem-solving approach to the topic, offering a hands-on guide for practicing engineers; ·         Provides realistic examples to inspire a thorough understanding of system-level issues, before going into the detail of components and devices; ·         Uses a new approach and provides several skills that help engineers and designers retain key and advanced concepts.

  18. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    Science.gov (United States)

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-apically. In the control group, horizontal external mattress sutures were applied instead of using a stent. After the surgical procedure, the width of the buccal keratinized mucosa was measured at the mesial, middle, and distal aspects of the healing abutment. The change in the width of the buccal keratinized mucosa was assessed at 1 and 3 months. Results Healing was uneventful in both groups. The difference of width between baseline and 1 month was −0.26±0.85 mm in the test group, without any statistical significance (P=0.137). Meanwhile, the corresponding difference in the control group was −0.74±0.73 mm and it showed statistical significance (Pprefabricated implant-retained stent was shown to be effective in the preservation of the keratinized mucosa around implants and it was simple and straightforward in comparison to the horizontal external mattress suture technique. PMID:27800215

  19. In vivo biofilm formation on stainless steel bonded retainers during different oral health-care regimens

    NARCIS (Netherlands)

    Jongsma, Marije A.; van der Mei, Henny C.; Atema-Smit, Jelly; Busscher, Henk I.; Ren, Yijin

    2015-01-01

    Retention wires permanently bonded to the anterior teeth are used after orthodontic treatment to prevent the teeth from relapsing to pre-treatment positions. A disadvantage of bonded retainers is biofilm accumulation on the wires, which produces a higher incidence of gingival recession, increased

  20. Adhesive Properties of Bonded Orthodontic Retainers to Enamel : Stainless Steel Wire vs Fiber-reinforced Composites

    NARCIS (Netherlands)

    Foek, Dave Lie Sam; Krebs, Eliza; Sandham, John; Ozcan, Mutlu

    2009-01-01

    Purpose: The objectives of this study were to compare the bond strength of a stainless steel orthodontic wire vs various fiber-reinforced composites (FRC) used as orthodontic retainers on enamel, analyze the failure types after debonding, and investigate the influence of different application

  1. Do we really understand how to retain nurses?

    Science.gov (United States)

    O'Brien-Pallas, Linda; Duffield, Christine; Hayes, Laureen

    2006-05-01

    To compare views of nurse executives with those of nurses who have left the profession on the importance of retention strategies. Although much has been written about nursing turnover, there continues to be dissonance among decision makers as to why nurses leave the profession and what the most crucial issues are for retention. Factor analysis was undertaken to compare responses of nurse executives with those of nurses employed outside of nursing. Contract requirements represented the greatest discrepancy, 1.07, followed by legal and employer issues, 1.02; worklife/homelife balance, 0.91; external values and beliefs about nursing, 0.75; and professional practice, 0.29. A disparity exists between perceptions of nurse executives and those of nurses who have left the profession as to which issues are most critical in retention. We suggest that nurse executives ensure sufficient organizational support for nursing unit managers who are more likely to understand methods of retaining nurses at the clinical interface.

  2. Pressure-Induced Bandgap Optimization in Lead-Based Perovskites with Prolonged Carrier Lifetime and Ambient Retainability

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Gang [Center for High Pressure Science and Technology Advanced Research, Shanghai 201203 China; Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Kong, Lingping [Center for High Pressure Science and Technology Advanced Research, Shanghai 201203 China; Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Gong, Jue [Department of Chemistry and Biochemistry, Northern Illinois University, DeKalb IL 60115 USA; Yang, Wenge [Center for High Pressure Science and Technology Advanced Research, Shanghai 201203 China; Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Mao, Ho-kwang [Center for High Pressure Science and Technology Advanced Research, Shanghai 201203 China; Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Hu, Qingyang [Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Liu, Zhenxian [Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Schaller, Richard D. [Center for Nanoscale Materials, Argonne National Laboratory, Argonne IL 60439 USA; Zhang, Dongzhou [Hawai' i Institute of Geophysics and Planetology, School of Ocean and Earth Science and Technology, University of Hawai' i at Manoa, Honolulu HI 96822 USA; Xu, Tao [Department of Chemistry and Biochemistry, Northern Illinois University, DeKalb IL 60115 USA

    2016-12-05

    Bond length and bond angle exhibited by valence electrons is essential to the core of chemistry. Using lead-based organic–inorganic perovskite compounds as an exploratory platform, it is demonstrated that the modulation of valence electrons by compression can lead to discovery of new properties of known compounds. Yet, despite its unprecedented progress, further efficiency boost of lead-based organic–inorganic perovskite solar cells is hampered by their wider bandgap than the optimum value according to the Shockley–Queisser limit. By modulating the valence electron wavefunction with modest hydraulic pressure up to 2.1 GPa, the optimized bandgap for single-junction solar cells in lead-based perovskites, for the first time, is achieved by narrowing the bandgap of formamidinium lead triiodide (HC(NH2)2PbI3) from 1.489 to 1.337 eV. Strikingly, such bandgap narrowing is partially retained after the release of pressure to ambient, and the bandgap narrowing is also accompanied with double-prolonged carrier lifetime. With First-principles simulation, this work opens a new dimension in basic chemical understanding of structural photonics and electronics and paves an alternative pathway toward better photovoltaic materials-by-design.

  3. Pressure-Induced Bandgap Optimization in Lead-Based Perovskites with Prolonged Carrier Lifetime and Ambient Retainability

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Gang [Center for High Pressure Science and Technology Advanced Research, Shanghai 201203 China; Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Kong, Lingping [Center for High Pressure Science and Technology Advanced Research, Shanghai 201203 China; Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Gong, Jue [Department of Chemistry and Biochemistry, Northern Illinois University, DeKalb IL 60115 USA; Yang, Wenge [Center for High Pressure Science and Technology Advanced Research, Shanghai 201203 China; Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Mao, Ho-kwang [Center for High Pressure Science and Technology Advanced Research, Shanghai 201203 China; Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Hu, Qingyang [Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Liu, Zhenxian [Geophysical Laboratory, Carnegie Institution of Washington, Washington DC 20015 USA; Schaller, Richard D. [Center for Nanoscale Materials, Argonne National Laboratory, Argonne IL 60439 USA; Zhang, Dongzhou [Hawai' i Institute of Geophysics and Planetology, School of Ocean and Earth Science and Technology, University of Hawai' i at Manoa, Honolulu HI 96822 USA; Xu, Tao [Department of Chemistry and Biochemistry, Northern Illinois University, DeKalb IL 60115 USA

    2016-12-05

    Bond length and bond angle exhibited by valence electrons is essential to the core of chemistry. Using lead-based organic–inorganic perovskite compounds as an exploratory platform, it is demonstrated that the modulation of valence electrons by compression can lead to discovery of new properties of known compounds. Yet, despite its unprecedented progress, further efficiency boost of lead-based organic–inorganic perovskite solar cells is hampered by their wider bandgap than the optimum value according to the Shockley–Queisser limit. By modulating the valence electron wavefunction with modest hydraulic pressure up to 2.1 GPa, the optimized bandgap for single-junction solar cells in lead-based perovskites, for the first time, is achieved by narrowing the bandgap of formamidinium lead triiodide (HC(NH2)2PbI3) from 1.489 to 1.337 eV. Strikingly, such bandgap narrowing is partially retained after the release of pressure to ambient, and the bandgap narrowing is also accompanied with double-prolonged carrier lifetime. With First-principles simulation, this work opens a new dimension in basic chemical understanding of structural photonics and electronics and paves an alternative pathway toward better photovoltaic materials-by-design.

  4. The Effect of Displacement Mode of Rigid Retaining Walls on Shearing Bands by Active Earth Pressure

    Directory of Open Access Journals (Sweden)

    A. Sekkel

    2013-10-01

    Full Text Available This work treats the physical modeling of failure mechanisms by active earth pressure. This last is developed by retaining wall movement. A lot of research showed that wall displacement has a significant effect on active earth pressure. A good comprehension of active earth pressure phenomenon and its failure mechanisms help us to better conceive retaining walls. The conception of a small-scale model allowed the realization of active earth pressure tests, while displacing the mobile wall toward the outside of the massif. The studied material is that of Schneebeli; light two-dimensional material made of cylindrical plastic rollers, simulating granular non-cohesive soil. The evolution of shearing zones under continuous and discontinuous displacement modes of mobile walls by correlation pictures allows the investigation of the localization of deformations and failure mechanisms.

  5. Enhanced Internet firewall design using stateful filters final report

    Energy Technology Data Exchange (ETDEWEB)

    Hutchins, J.A. [Sandia National Labs., Livermore, CA (United States). Infrastructure and Networking Research Dept.; Simons, R.W. [Sandia National Labs., Albuquerque, NM (United States). Decision Support Systems Architectures

    1997-08-01

    The current state-of-the-art in firewall design provides a lot of security for company networks, but normally at the expense of performance and/or functionality. Sandia researched a new approach to firewall design which incorporates a highly stateful approach, allowing much more flexibility for protocol checking and manipulation while retaining performance. A prototype system was built and multiple protocol policy modules implemented to test the concept. The resulting system, though implemented on a low-power workstation, performed almost at the same performance as Sandia`s current firewall.

  6. Learning from experience: feedback to CANDU design

    International Nuclear Information System (INIS)

    Allen, P.J.; Hopwood, J.M.; Rousseau, G.P.

    1998-01-01

    AECL's main product line is based on two single unit CANDU nuclear power plant designs; CANDU 6 and CANDU 9, each of which is based on successfully operating CANDU plants. AECL's CANDU development program is based upon evolutionary improvement. The evolutionary design approach ensures the maximum degree of operational provenness. It also allows successful features of today's plants to be retained while incorporating improvements as they develop to the appropriate level of design maturity. A key component of this evolutionary development is a formal process of gathering and responding to feedback from: NPP operation, construction and commissioning; regulatory input; equipment supplier input; R and D results; market input. The progresses for gathering and implementing the experience feedback and a number of recent examples of design improvements from this feedback process are described in the paper. (author)

  7. Effect of plastic soil on a retaining wall subjected to surcharge loading

    Directory of Open Access Journals (Sweden)

    Al-Juari Khawla

    2016-01-01

    Full Text Available The seasonal variation and climatic changes play a significant role that affects the stresses exerted on a retaining wall, and the state of stresses in the soil mass behind the wall especially for highly expansive soil. These stresses resulted in the wall moving either away or towards the soil. In this study, a laboratory physical model of the retaining wall formed of a box having (950×900×600 mm dimensions with one side representing the wall being developed. After the soil being laid out in the box in specified layers, specified conditions of saturation and normal stresses were applied. The wall is allowed to move horizontally in several distances (0.1, 0.2, 0.3, 0.6, 0.8, 1.0 , 2.0, 3.0 and 4.0 mm, and the stresses being measured, then the vertical loading was released. The main measured variables during the tests are; the active and passive earth pressures, vertical movement of the soil, total suction and time. Results showed that the lateral earth pressure along the depth of the wall largely decreased when wall moved away from the soil. Total suction was slightly affected during wall’s movement. At unloading stage, the lateral earth pressure decreased at the upper half of wall height, but increased at the other wall part. Total suction was increased at all depths during this stage.

  8. Mechanical testing - designers need: a view at component design and operations stages

    International Nuclear Information System (INIS)

    Shrivastava, S.K.

    2007-01-01

    Mechanical design of any component requires knowledge of values of various material properties which designer(s) make(s) use in designing the component. In design of nuclear power plant components, it assumes even greater importance in view of degree of precision and accuracy with which the values of various properties are required. This is in turn demands, high accuracy in testing machines and measuring methods. In this paper, attempt has been made to bring out that even from conventional tension test, how designer today looks for availability of engineering stress-strain diagram preferably through digitally acquired data points during the test from which he can derive values of Ramberg-Osgood parameters for use in fracture mechanics based analysis. Attempt has been also made to provide account of some of important fracture mechanics related tests which have been evolved in last two decades and designers need for evolution of simple test techniques to measure many more fracture mechanics related parameters as well as cater to constraints such as shape and size of material available from the components. Nuclear power plant has been primarily kept in view and ASME. Section III NB, ASME Section XI and relevant ASTM Standards have been taken as standard references. Further pressure retaining materials of pressure vessels/Reactor Pressure Vessels have been kept in view. (author)

  9. Implant-Supported Telescopic Crown-Retained Overdentures for Oral Rehabilitation of Patients with Severe Bony Defects: A 5-Year Retrospective Study.

    Science.gov (United States)

    Zou, Duohong; Wang, Feng; Wu, Yiqun; Huang, Wei; Zhang, Chenping; Zhang, Zhiyuan

    2015-01-01

    To evaluate the performance of dental implant-supported telescopic crown (TC)-retained overdentures to restore the oral function of patients who have insufficient jawbone volume resulting from tumor resection or trauma. From January 2004 to December 2008, implant-supported TC-retained overdentures were used to restore the oral function of patients with severe bony defects resulting from tumor resection or trauma. Clinical data, including implant success and survival rates, biologic and mechanical complications, prosthodontic maintenance efforts, and patient satisfaction, were analyzed annually after delivery of the final prostheses. Twenty-four patients were treated, and a total of 88 implants were inserted to support TC-retained overdentures. The mean modified plaque index of implants remained low (76.3%) in the study showed the absence of bleeding on probing at follow-up visits. Peri-implant marginal bone loss (MBL) ranged from 0.8 to 1.2 mm. There was no statistically significant difference in the MBL between maxillary and mandibular implants (P = .43). The implant success rate was 100% after 5 years, and the prosthodontic maintenance and complication rate was 0.22 times per year. More than 90% of patients were satisfied with the restoration of their oral function using TCs. Based on our study of 24 patients treated with TC-retained overdentures, it appears that this treatment may be a viable option for patients with insufficient jawbone volume.

  10. Peer Contexts: Do Old for Grade and Retained Peers Influence Student Behavior in Middle School?

    Science.gov (United States)

    Muschkin, Clara G.; Glennie, Elizabeth; Beck, Audrey N.

    2014-01-01

    Background: Many school systems have ended social promotion by implementing accountability systems where students who fail academic assessments are retained in grade. Additionally, some parents have delayed their children's entry into school, believing that older students have an advantage. While research has examined outcomes for students who…

  11. Recruiting and Retaining an Ethnically Diverse Sample of Older Adults in a Longitudinal Intervention Study

    Science.gov (United States)

    Austin-Wells, Vonnette; McDougall, Graham J.; Becker, Heather

    2006-01-01

    This paper describes strategies developed to recruit and retain an ethnically diverse sample in a longitudinal intervention of 246 participants in the SeniorWISE study. The ethnic and socioeconomic differences of these participants necessitated the use of different methods of effectively communicating with this population. Recruitment benefited…

  12. Self-retaining small-looped catheter for narrow bile ducts in high common bile duct obstruction

    International Nuclear Information System (INIS)

    Guenther, R.W.; Daehnert, W.

    1985-01-01

    A new self-retaining catheter was devised for percutaneous drainage of small bile ducts. The device allows safe external drainage without the risk of catheter dislocation even in high bile duct obstruction. The catheter is also suitable for percutaneous nephrostomy in non-dilated pyelocaliceal system. (orig.)

  13. The S.M.A.R.T. Strategy to Recruiting and Retaining High School Coaches

    Science.gov (United States)

    Lubisco, Robyn; Birren, Genevieve F. E.

    2017-01-01

    This article discusses the S.M.A.R.T. strategy for recruiting and retaining quality high school coaches. S.M.A.R.T. stands for Scouting, Mentoring and Coaching, Appreciation, Rating, and Time. Scouting addresses how one goes about locating and hiring quality coaches. Mentoring and Coaching addresses how to develop the coach within the specific…

  14. K-12 Education Nonprofit Employees' Perceptions of Strategies for Recruiting and Retaining Employees

    Science.gov (United States)

    Byrne, Tara Marie

    2013-01-01

    This qualitative study explored the key reasons individuals who work in K-12 education nonprofit organizations enter the field of K-12 nonprofit education and their motivations for doing so. The purpose of this study was to find new strategies for recruiting and retaining K-12 education nonprofit employees by examining the obstacles that exist to…

  15. Language learning apps or games: an investigation utilizing the RETAIN model

    Directory of Open Access Journals (Sweden)

    Glenda A. Gunter

    2016-01-01

    Full Text Available Abstract: Combining games with mobile devices can promote learning opportunities at the learners' fingertips and enable ubiquitous learning experiences. As teachers increasingly assign games to reinforce language learning, it becomes essential to evaluate how effective these applications are in helping students learn the content or develop the skills that the games are reinforcing. This article examines two English language learning apps under the RETAIN model (GUNTER; KENNY; VICK, 2008. The findings indicate that although these apps offer some language learning opportunities, they do not present scenario-based quality or gameplay, among other elements, if they are to be considered games.

  16. AUTOMATIC THICKNESS AND VOLUME ESTIMATION OF SPRAYED CONCRETE ON ANCHORED RETAINING WALLS FROM TERRESTRIAL LIDAR DATA

    Directory of Open Access Journals (Sweden)

    J. Martínez-Sánchez

    2016-06-01

    Full Text Available When ground conditions are weak, particularly in free formed tunnel linings or retaining walls, sprayed concrete can be applied on the exposed surfaces immediately after excavation for shotcreting rock outcrops. In these situations, shotcrete is normally applied conjointly with rock bolts and mesh, thereby supporting the loose material that causes many of the small ground falls. On the other hand, contractors want to determine the thickness and volume of sprayed concrete for both technical and economic reasons: to guarantee their structural strength but also, to not deliver excess material that they will not be paid for. In this paper, we first introduce a terrestrial LiDAR-based method for the automatic detection of rock bolts, as typically used in anchored retaining walls. These ground support elements are segmented based on their geometry and they will serve as control points for the co-registration of two successive scans, before and after shotcreting. Then we compare both point clouds to estimate the sprayed concrete thickness and the expending volume on the wall. This novel methodology is demonstrated on repeated scan data from a retaining wall in the city of Vigo (Spain, resulting in a rock bolts detection rate of 91%, that permits to obtain a detailed information of the thickness and calculate a total volume of 3597 litres of concrete. These results have verified the effectiveness of the developed approach by increasing productivity and improving previous empirical proposals for real time thickness estimation.

  17. Automatic Thickness and Volume Estimation of Sprayed Concrete on Anchored Retaining Walls from Terrestrial LIDAR Data

    Science.gov (United States)

    Martínez-Sánchez, J.; Puente, I.; GonzálezJorge, H.; Riveiro, B.; Arias, P.

    2016-06-01

    When ground conditions are weak, particularly in free formed tunnel linings or retaining walls, sprayed concrete can be applied on the exposed surfaces immediately after excavation for shotcreting rock outcrops. In these situations, shotcrete is normally applied conjointly with rock bolts and mesh, thereby supporting the loose material that causes many of the small ground falls. On the other hand, contractors want to determine the thickness and volume of sprayed concrete for both technical and economic reasons: to guarantee their structural strength but also, to not deliver excess material that they will not be paid for. In this paper, we first introduce a terrestrial LiDAR-based method for the automatic detection of rock bolts, as typically used in anchored retaining walls. These ground support elements are segmented based on their geometry and they will serve as control points for the co-registration of two successive scans, before and after shotcreting. Then we compare both point clouds to estimate the sprayed concrete thickness and the expending volume on the wall. This novel methodology is demonstrated on repeated scan data from a retaining wall in the city of Vigo (Spain), resulting in a rock bolts detection rate of 91%, that permits to obtain a detailed information of the thickness and calculate a total volume of 3597 litres of concrete. These results have verified the effectiveness of the developed approach by increasing productivity and improving previous empirical proposals for real time thickness estimation.

  18. Meta-analysis comparing same-day versus delayedvitrectomy clinical outcomes for intravitreal retained lens fragments after age-relatedcataract surgery

    Directory of Open Access Journals (Sweden)

    Vanner EA

    2014-11-01

    Full Text Available Elizabeth A Vanner,1 Michael W Stewart21Department of Preventive Medicine, Pathology and Bioinformatics, Stony Brook University, Stony Brook, NY, USA; 2Department of Ophthalmology, Mayo Clinic College of Medicine, Jacksonville, FL, USAPurpose/design: We aimed to perform a systematic review and meta-analysis comparing the risk difference of clinical outcomes for same-day (SD vs delayed (DEL pars plana vitrectomy (PPV.Methods: We searched MEDLINE (English; January 1, 1985 to July 16, 2013 and article reference lists, for patients with crystalline retained lens fragments and discussion of SD-PPV vs DEL-PPV. For the meta-analysis, articles needed the number of patients receiving SD-PPV and DEL-PPV, and the number, in each group, who experienced one or more of the outcomes: not good visual acuity (VA (<20/40, bad VA (≤20/200, retinal detachment, increased intraocular pressure/glaucoma, intraocular infection/inflammation, cystoid macular edema, and corneal edema.Results: Of 304 articles identified, 23 provided data for the meta-analysis. Results were mixed, indicating 1 neither vitrectomy time produced better outcomes in all studies (not good VA risk difference =10.3% [positive numbers favored SD-PPV; negative numbers favored DEL-PPV], 95% confidence interval [CI] = [-0.4% to 21.0%], P=0.059; and bad VA risk difference =-0.3%, 95% CI = [-10.7% to 10.1%], P=0.953; 2 better outcomes with immediate SD-PPV compared with all DEL-PPV (not good VA risk difference =16.2%, 95% CI = [0.8% to 31.5%], P=0.039; and bad VA risk difference =8.5%; 95% CI = [0.8% to 16.2%], P=0.030; and 3 immediate SD-PPV and prompt DEL-PPV (3 to 14 days after cataract surgery had no significant differences and so may produce similar outcomes (not good VA risk differences range = [-19.9% to 6.5%], 95% CI = [-59.9% to 36.4%]; and bad VA risk differences range = [-6.9% to 7.4%], 95% CI = [-33.1% to 31.8%].Conclusion: Perhaps SD-PPV should be limited to facilities at which a

  19. Taking Educational Games Seriously: Using the RETAIN Model to Design Endogenous Fantasy into Standalone Educational Games

    Science.gov (United States)

    Gunter, Glenda A.; Kenny, Robert F.; Vick, Erik H.

    2008-01-01

    We are witnessing a mad rush to pour educational content into games in an ad hoc manner in hopes that player/learners are motivated simply because the content is housed inside a game. A failure to base educational game design on well-established learning and instructional theories increases the risk of the game failing to meet its intended…

  20. Ignalina RBMK-1500 building capability in retaining radioactive releases

    International Nuclear Information System (INIS)

    Nilsson, Lars; Johansson, K.

    1993-01-01

    The Ignalina reactor building structures are capable of retaining substantial fractions of radioactive emissions from the fuel core, in those accident sequences where pressurization failure of structures can be averted by pressure relief arrangements. In stage 1 of the IBBA project it was demonstrated that enhanced retention of radioactive fission products within the plant can be achieved if natural convection is facilitated in the upper building compartments. In this report of stage 2 is discussed for which accident sequences the introduction of natural convection in combination with the existing forced convection ventilation and the accident localization system can improve the total safety of Ignalina 1-2. The purpose of this stage is to provide a basis for further review and more detailed studies of the natural convection concept, its benefits and disadvantages, and of the feasability to introduce the concept in existing plants

  1. Language comprehenders retain implied shape and orientation of objects.

    Science.gov (United States)

    Pecher, Diane; van Dantzig, Saskia; Zwaan, Rolf A; Zeelenberg, René

    2009-06-01

    According to theories of embodied cognition, language comprehenders simulate sensorimotor experiences to represent the meaning of what they read. Previous studies have shown that picture recognition is better if the object in the picture matches the orientation or shape implied by a preceding sentence. In order to test whether strategic imagery may explain previous findings, language comprehenders first read a list of sentences in which objects were mentioned. Only once the complete list had been read was recognition memory tested with pictures. Recognition performance was better if the orientation or shape of the object matched that implied by the sentence, both immediately after reading the complete list of sentences and after a 45-min delay. These results suggest that previously found match effects were not due to strategic imagery and show that details of sensorimotor simulations are retained over longer periods.

  2. Advanced dependent pressure vessel (DPV) nickel-hydrogen spacecraft battery design

    Energy Technology Data Exchange (ETDEWEB)

    Coates, D.K.; Grindstaff, B.; Swaim, O.; Fox, C. [Eagle-Picher Industries, Inc., Joplin, MO (United States). Advanced Systems Operation

    1995-12-31

    The dependent pressure vessel (DPV) nickel-hydrogen (NiH{sub 2}) battery is being developed as a potential spacecraft battery design for both military and commercial satellites. The limitations of standard NiH{sub 2} individual pressure vessel (IPV) flight battery technology are primarily related to the internal cell design and the battery packaging issues associated with grouping multiple cylindrical cells. The DPV cell design offers higher energy density and reduced cost, while retaining the established IPV technology flight heritage and database. The advanced cell design offers a more efficient mechanical, electrical and thermal cell configuration and a reduced parts count. The geometry of the DPV cell promotes compact, minimum volume packaging and weight efficiency. The DPV battery design offers significant cost and weight savings advantages while providing minimal design risks.

  3. Asian gardens: history, beliefs and design

    OpenAIRE

    Turner, Tom

    2010-01-01

    [Book description from publisher's website]\\ud The gardens made on the fringes of Central Asia in the past 5000 years form a great arc. From the Fertile Crescent, it runs west to Europe and east to China and Japan. Asia's fringe was a zone of interchange: a vast landscape in which herders encountered farmers and the design of symbolic gardens began. It appears that as they became settlers, nomads retained a love of mobility, hunting and the wild places in which their ancestors had roamed. Cen...

  4. Tensile Creep and Fatigue of Sylramic-iBN Melt-Infiltrated SiC Matrix Composites: Retained Properties, Damage Development, and Failure Mechanisms

    Science.gov (United States)

    Morscher, Greg; Gowayed, yasser; Miller, Robert; Ojard, Greg; Ahmad, Jalees; Santhosh, Unni; John, Reji

    2008-01-01

    An understanding of the elevated temperature tensile creep, fatigue, rupture, and retained properties of ceramic matrix composites (CMC) envisioned for use in gas turbine engine applications are essential for component design and life-prediction. In order to quantify the effect of stress, time, temperature, and oxidation for a state-of-the-art composite system, a wide variety of tensile creep, dwell fatigue, and cyclic fatigue experiments were performed in air at 1204 C for the SiC/SiC CMC system consisting of Sylramic-iBN SiC fibers, BN fiber interphase coating, and slurry-cast melt-infiltrated (MI) SiC-based matrix. Tests were either taken to failure or interrupted. Interrupted tests were then mechanically tested at room temperature to determine the residual properties. The retained properties of most of the composites subjected to tensile creep or fatigue were usually within 20% of the as-produced strength and 10% of the as-produced elastic modulus. It was observed that during creep, residual stresses in the composite are altered to some extent which results in an increased compressive stress in the matrix upon cooling and a subsequent increased stress required to form matrix cracks. Microscopy of polished sections and the fracture surfaces of specimens which failed during stressed-oxidation or after the room-temperature retained property test was performed on some of the specimens in order to quantify the nature and extent of damage accumulation that occurred during the test. It was discovered that the distribution of stress-dependent matrix cracking at 1204 C was similar to the as-produced composites at room temperature; however, matrix crack growth occurred over time and typically did not appear to propagate through thickness except at final failure crack. Failure of the composites was due to either oxidation-induced unbridged crack growth, which dominated the higher stress regime (> 179 MPa) or controlled by degradation of the fibers, probably caused by

  5. The Role of Radio Frequency Detection System Embedded Surgical Sponges in Preventing Retained Surgical Sponges: A Prospective Evaluation in Patients Undergoing Emergency Surgery.

    Science.gov (United States)

    Inaba, Kenji; Okoye, Obi; Aksoy, Hande; Skiada, Dimitra; Ault, Glenn; Sener, Stephen; Lam, Lydia; Benjamin, Elizabeth; Demetriades, Demetrios

    2016-10-01

    To prospectively evaluate the ability of radio frequency detection (RFD) system-embedded sponges to mitigate the incidence of retained surgical sponges (RSS) after emergency surgery. Emergency surgery patients are at high risk for retained foreign bodies. All emergent trauma and nontrauma cavitary operations over a 5-year period (January 2010-December 2014) were prospectively enrolled. For damage-control procedures, only the definitive closure was included. RFD sponges were used exclusively throughout the study period. Before closure, the sponge and instrument count was followed by RFD scanning and x-ray evaluation for retained sponges. RSS and near-misses averted using the RFD system were analyzed. In all, 2051 patients [median (range)], aged 41 (1-101) years, 72.2% male, 46.8% trauma patients, underwent 2148 operations (1824 laparotomy, 100 thoracotomy, 30 sternotomy, and 97 combined). RFD detected retained sponges in 11 (0.5%) patients (81.8%laparotomy, 18.2% sternotomy) before cavitary closure. All postclosure x-rays were negative. No retained sponges were missed by the RFD system. Body mass index was 29 (23-43), estimated blood loss 1.0 L (0-23), and operating room time 160 minutes (71-869). Procedures started after 18:00 to 06:00 hours in 45.5% of the patients. The sponge count was incorrect in 36.4%, not performed due to time constraints in 45.5%, and correct in 18.2%. The additional cost of using RFD-embedded disposables was $0.17 for a 4X18 laparotomy sponge and $0.46 for a 10 pack of 12ply, 4X8. Emergent surgical procedures are high-risk for retained sponges, even when sponge counts are performed and found to be correct. Implementation of a RFD system was effective in preventing this complication and should be considered for emergent operations in an effort to improve patient safety.

  6. Seismic analysis and design of spent subassembly storage bay (SSSB) pool

    International Nuclear Information System (INIS)

    Abdul Gani, H.I.; Ramanjaneyulu, K.V.S.; Pillai, C.S.; Chetal, S.C.

    2003-01-01

    Fuel bundles, after their specified stay in reactor core, are replaced by fresh fuel for sustaining power generation at rated levels. The irradiated fuel subassembly, removed fresh from core, known as spent fuel sub assembly, is radioactive and decay heat generating. It needs to be cooled before it becomes amenable for handling, either for reprocessing or for immobilisation. For this purpose, it is immersed in a pool of water, retained in a concrete structure referred as Spent Subassembly Storage Bay (SSSB) pool. The height of water column above fuel bundles is arrived from shielding considerations. SSSB pool is one of the nuclear safety related structures and warrants rigorous analysis and design. The SSSB pool, in case of PFBR 500 MW(e) is located in fuel building. It is a stainless steel lined. water retaining rectangular R.C.C. open tank of size 7.5 X 29.0 m, with a height of 11.0 m. This structure is analysed for two levels of site specific earthquakes taking in to account liquid structure interactions as per ASCE-4, 1998. The design of walls and bottom slab is carried out satisfying the AERB code for nuclear safety related structures. Analysis and design of SSSB pool of PFBR is presented in the following paper. (author)

  7. Effects of Hardness on Pintle Rod Performance in the Universal and Retained Gas Samplers

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    Interaction between hardness of the pintle rods and the retainer rings used in the core samplers is investigated. It is found that ordinary Rockwell C measurements are not sufficient and superficial hardness instruments are recommended to verify hardness since in-production hardness of pintle rods is found to vary widely and probably leads to some premature release of pistons in samplers

  8. A CAD/CAM Zirconium Bar as a Bonded Mandibular Fixed Retainer: A Novel Approach with Two-Year Follow-Up

    Science.gov (United States)

    Hassan, Rozita; Hanoun, Abdul Fatah

    2017-01-01

    Stainless steel alloys containing 8% to 12% nickel and 17% to 22% chromium are generally used in orthodontic appliances. A major concern has been the performance of alloys in the environment in which they are intended to function in the oral cavity. Biodegradation and metal release increase the risk of hypersensitivity and cytotoxicity. This case report describes for the first time a CAD/CAM zirconium bar as a bonded mandibular fixed retainer with 2-year follow-up in a patient who is subjected to long-term treatment with fixed orthodontic appliance and suspected to have metal hypersensitivity as shown by the considerable increase of nickel and chromium concentrations in a sample of patient's unstimulated saliva. The CAD/CAM design included a 1.8 mm thickness bar on the lingual surface of lower teeth from canine to canine with occlusal rests on mesial side of first premolars. For better retention, a thin layer of feldspathic ceramic was added to the inner surface of the bar and cemented with two dual-cured cement types. The patient's complaint subsided 6 weeks after cementation. Clinical evaluation appeared to give good functional value where the marginal fit of digitized CAD/CAM design and glazed surface offered an enhanced approach of fixed retention. PMID:28819572

  9. Effect of different surface treatments and retainer designs on the retention of posterior Pd-Ag porcelain-fused-to-metal resin-bonded fixed partial dentures.

    Science.gov (United States)

    Chen, Xiwen; Zhang, Yixin; Zhou, Jinru; Chen, Chenfeng; Zhu, Zhimin; Li, Lei

    2018-02-01

    The aim of this study was to investigate the adhesive property of palladium-silver alloy (Pd-Ag) and the simulated clinical performance of Pd-Ag porcelain-fused-to-metal (PFM), resin-bonded, fixed partial dentures (RBFPDs). A total of 40 Pd-Ag discs (diameter=5 mm) were prepared and divided into the following four groups (n=10): a) No sandblasting, used as a control; and b, 50 µm; c, 110 µm; and d, 250 µm aluminum oxide (Al 2 O 3 ) particles, respectively. Another 50 discs were pre-sandblasted and divided into five groups (n=10) subjected to different treatments: e) Sandblasting, used as a control; f) silane; g) alloy primer; h) silica coating + silane and i) silica coating + alloy primer. All 90 discs were bonded to enamel with Panavia F 2.0 and then subjected to shear bond strength (SBS) testing. The fracture surfaces were examined by scanning electron microscopy. Next, 40 missing maxillary second premolar models were restored with one of the four following RBFPD designs (n=10): I) A premolar occlusal bar combined with molar double rests (MDR); II) both occlusal bars with a wing (OBB); III) a premolar occlusal bar combined with a molar dental band (MDB); and IV) two single rests adjacent to the edentulous space with a wing (SRB) used as a control. All specimens were aged with thermal cycling and mechanical loading. Subsequently, they were loaded until broken. The data were analyzed by one-way analysis of variance. Al 2 O 3 (250 µm) abrasion provided the highest SBS (P<0.05). The alloy primer and silica + silane exhibited increased SBS. Furthermore, fracture analysis revealed that the failure mode varied among the different treatments. Whereas MDB exhibited the highest retention (P<0.05), that of OBB was greater than that of MDR (P<0.05), and the control exhibited the lowest retention. Abrasion with Al 2 O 3 (250 µm) effectively increased the adhesive property of Pd-Ag. Additionally, treatment with the alloy primer and silica coating + silane was able to

  10. Method for the calculation of volumetric fraction of retained austenite through the software for analysis of digital images

    International Nuclear Information System (INIS)

    Lombardo, S.; Costa, F.H.; Hashimoto, T.M.; Pereira, M.S.; Abdalla, A.J.

    2010-01-01

    In order to calculate the volume fraction of the retained austenite in aeronautic multiphase steels, it was used a digital analysis software for image processing. The materials studied were steels AISI 43XX with carbon content between 30, 40 and 50%, heat treated by conventional quenching and isothermal cooling in bainitic and intercritical region, characterized by optical microscopy, etching by reagent Sodium Metabisulfite (10%) for 30 seconds, with forced drying. The results were compared with the methods of X-Ray Diffraction and Magnetic Saturation through photomicrographs, showing that with this technic it is possible to quantify the percentage of retained austenite in the martensitic matrix, in the different types of steels. (author)

  11. Synthesis and characterization of tissue-retainable methylsulfonyl polychlorinated biphenyl isomers

    International Nuclear Information System (INIS)

    Haraguchi, K.; Kuroki, H.; Masuda, Y.

    1987-01-01

    Eighty-six positional isomers of methylsulfonyl polychlorinated biphenyls (MSF-PCBs) have been synthesized by three synthetic routes: (1) the diazo coupling reaction of 3-(methylsulfonyl)chloroaniline with chlorobenzene; (2) nucleophilic substitution of PCB with methanethiolate and successive oxidation of the corresponding methyl sulfide; (3) the diazo coupling reaction of chloroaniline with chlorothioanisole and successive oxidation of the methyl sulfide. Pure isomers were characterized by their proton magnetic resonance and mass spectra and used to unambiguously identify the MSF metabolites retained in human tissues by using high-resolution capillary gas chromatography (GC). The GC analysis showed that 40 MSF derivatives were positively identified in the tissue of a patient with Yusho on the basis of comparisons of their GC retention data with those of the standard compounds

  12. The Innovative Structure Solution for Preventing Salt Intrusion and Retaining Freshwater In Mekong Delta VietNam

    NARCIS (Netherlands)

    Hong, S.T.; Vrijling, J.K.; Stive, M.J.F.

    2013-01-01

    In the Mekong Delta Vietnam, the construction of sluices with the purpose of retaining fresh water and preventing salt water intrusion potentially plays a very important role. However, the structures constructed in small rivers according to local or traditional technology revealed many disadvantages

  13. Optimized core design and fuel management of a pebble-bed type nuclear reactor

    NARCIS (Netherlands)

    Boer, B.

    2009-01-01

    The core design of a pebble-bed type Very High Temperature Reactor (VHTR) is optimized, aiming for an increase of the coolant outlet temperature to 1000 C, while retaining its inherent safety features. The VHTR has been selected by the international Generation IV research initiative as one of the

  14. Design of optically stable image reflector system.

    Science.gov (United States)

    Tsai, Chung-Yu

    2013-08-01

    The design of a partially optically stable (POS) reflector system, in which the exit ray direction and image pose are unchanged as the reflector system rotates about a specific directional vector, was presented in an earlier study by the current group [Appl. Phys. B100, 883-890 (2010)]. The present study further proposes an optically stable image (OSI) reflector system, in which not only is the optical stability property of the POS system retained, but the image position and total ray path length are also fixed. An analytical method is proposed for the design of OSI reflector systems comprising multiple reflectors. The validity of the proposed approach is demonstrated by means of two illustrative examples.

  15. Reflections on Recruiting, Supporting, Retaining, Graduating, and Obtaining Employment for Doctoral Students from Diverse Backgrounds

    Science.gov (United States)

    Dieker, Lisa; Wienke, Wilfred; Straub, Carrie; Finnegan, Lisa

    2014-01-01

    In this article, the authors provide a summary of the current techniques being used to recruit, retain, and support a diverse range of scholars, including students with disabilities, in a doctoral program. The manuscript provides a summary of the current need for leadership personnel who are scholars with knowledge in special education, general…

  16. Three Dimensional Finite Element Analysis of Distal Abutment Stresses of Removable Partial Dentures with Different Retainer Designs.

    Science.gov (United States)

    Zarrati, Simindokht; Bahrami, Mehran; Heidari, Fatemeh; Kashani, Jamal

    2015-06-01

    This finite element method study aimed to compare the amount of stress on an isolated mandibular second premolar in two conventional reciprocal parallel interface designs of removable partial dentures (RPDs) and the same RPD abutment tooth (not isolated). A Kennedy Class 1, modification 1 RPD framework was simulated on a 3D model of mandible with three different designs: an isolated tooth with a mesial rest, an isolated tooth with mesial and distal rests and an abutment with a mesial rest (which was not isolated); 26 N occlusal forces were exerted bilaterally on the first molar sites. Stress on the abutment teeth was analyzed using Cosmos Works 2009 Software. In all designs, the abutment tooth stress concentration was located in the buccal alveolar crest. In the first model, the von Mises stress distribution in the contact area of I-bar clasp and cervical portion of the tooth was 19 MPa and the maximum stress was 30 MPa. In the second model, the maximum von Mises stress distribution was 15 MPa in the cervical of the tooth. In the third model, the maximum von Mises stress was located in the cervical of the tooth and the distal proximal plate. We recommend using both mesial and distal rests on the distal abutment teeth of distal extension RPDs. The abutment of an extension base RPD, which is not isolated in presence of its neighboring more anterior tooth, may have a better biomechanical prognosis.

  17. Recruiting and Retaining LGBTQ-Identified Staff in Academic Libraries Through Ordinary Methods

    Directory of Open Access Journals (Sweden)

    Elliott Kuecker

    2017-03-01

    Full Text Available In Brief While the American academic library field works hard to include all patrons and materials that represent less dominant populations, it should be more mindful of inclusivity in its own workforce. Particularly, the field does nothing to explicitly recruit or retain LGBTQ-identified librarians. The author proposes practical remedies to these problems that directly respond to workplace studies on interpersonal difficulties LGBTQ-identified librarians and others have cited as barriers to happiness in the workplace, and argues toward more inclusive LIS education and financial support.

  18. Precision Fit of Screw-Retained Implant-Supported Fixed Dental Prostheses Fabricated by CAD/CAM, Copy-Milling, and Conventional Methods.

    Science.gov (United States)

    de França, Danilo Gonzaga; Morais, Maria Helena; das Neves, Flávio D; Carreiro, Adriana Fonte; Barbosa, Gustavo As

    The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses. Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium. Four zirconia frameworks were fabricated using the copy-milled system, and four were cast in cobalt-chromium using conventional casting with premachined abutments. The vertical and horizontal misfit at the implant-framework interface was measured using scanning electron microscopy at ×250. The results for vertical misfit were analyzed using Kruskal-Wallis and Mann-Whitney tests. The horizontal misfits were categorized as underextended, equally extended, or overextended. Statistical analysis established differences between groups according to the chi-square test (α = .05). The mean vertical misfit was 5.9 ± 3.6 μm for CAD/CAM-fabricated zirconia, 1.2 ± 2.2 μm for CAD/CAM-fabricated cobalt-chromium frameworks, 7.6 ± 9.2 μm for copy-milling-fabricated zirconia frameworks, and 11.8 (9.8) μm for conventionally fabricated frameworks. The Mann-Whitney test revealed significant differences between all but the zirconia-fabricated frameworks. A significant association was observed between the horizontal misfits and the fabrication method. The percentage of horizontal misfits that were underextended and overextended was higher in milled zirconia (83.3%), CAD/CAM cobaltchromium (66.7%), cast cobalt-chromium (58.3%), and CAD/CAM zirconia (33.3%) frameworks. CAD/CAM-fabricated frameworks exhibit better vertical misfit and low variability compared with copy-milled and conventionally fabricated frameworks. The percentage of interfaces equally extended was higher when CAD/CAM and zirconia were used.

  19. The aging nursing workforce: How to retain experienced nurses.

    Science.gov (United States)

    Cohen, Jeremye D

    2006-01-01

    In the face of an anticipated nursing shortage, healthcare organizations must evaluate their culture, operations, and compensation system to ensure that these elements align with organizational efforts to retain nurses who are approaching retirement age. Management should focus on enhancing elements of job satisfaction and job embeddedness that will motivate nurses to remain both in the workforce and with their employer. Although much of this responsibility falls on the nurse manager, nurse managers are often not provided the necessary support by top management and are neither recognized nor held accountable for nurse turnover. Other retention initiatives can include altering working conditions to reduce both physical and mental stress and addressing issues of employee health and safety. As for compensation, organizations may be well-served by offering senior nursing staff flexible working hours, salary structures that reward experience, and benefit programs that hold value for an aging workforce.

  20. ''Compact'' reversed-field pinch (CRFP) reactor design

    International Nuclear Information System (INIS)

    Miley, G.H.; Nebel, R.A.

    1980-01-01

    These results indicate that a CRFP operating in the range of 100 MWe should be feasible. While the large aspect ratio leads to a 6.4-m major radius, the design still retains many attributes of conventional compact tori, such as simplicity and ease of access. The relatively low Q/sub p/ with batch burns might be satifactory for a demonstration unit. However, to obtain power-plant ''grade'' Q/sub p/, either refueling (possibly by pellets) or larger size plasmas appear necessary