WorldWideScience

Sample records for nano-liquid chromatography-electrospray ionization

  1. Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Santa, Tomofumi

    2011-01-01

    Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds. 2010 John Wiley & Sons, Ltd.

  2. CHARACTERIZATION OF DANSYLATED CYSTEINE, GLUTATHIONE DISULFIDE, CYSTEINE AND CYSTINE BY NARROW BORE LIQUID CHROMATOGRAPHY/ELECTROSPRAY IONIZATION MASS SPECTROMETRY

    Science.gov (United States)

    A method using reversed phase high performance liquid chromatography/electrospray ionization-mass spectrometric (RP-LC/ESI-MS) method has been developed to confirm the identity of dansylated derivatives of cysteine and glutathione, and their respective dimers. Cysteine, GSH, CSSC...

  3. Quantification of cardiolipin by liquid chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Garrett, Teresa A; Kordestani, Reza; Raetz, Christian R H

    2007-01-01

    Cardiolipin (CL), a tetra-acylated glycerophospholipid composed of two phosphatidyl moieties linked by a bridging glycerol, plays an important role in mitochondrial function in eukaryotic cells. Alterations to the content and acylation state of CL cause mitochondrial dysfunction and may be associated with pathologies such as ischemia, hypothyrodism, aging, and heart failure. The structure of CL is very complex because of microheterogeneity among its four acyl chains. Here we have developed a method for the quantification of CL molecular species by liquid chromatography-electrospray ionization mass spectrometry. We quantify the [M-2H](2-) ion of a CL of a given molecular formula and identify the CLs by their total number of carbons and unsaturations in the acyl chains. This method, developed using mouse macrophage RAW 264.7 tumor cells, is broadly applicable to other cell lines, tissues, bacteria and yeast. Furthermore, this method could be used for the quantification of lyso-CLs and bis-lyso-CLs.

  4. Quantitation of tamsulosin in human plasma by liquid chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Din, Li; Li, Limin; Tao, Ping; Yang, Jin; Zhang, Zhengxing

    2002-02-05

    A highly sensitive method for quantitation of tamsulosin in human plasma using 1-(2,6-dimethyl-3-hydroxylphenoxy)-2-(3,4-methoxyphenylethylamino)-propane hydrochloride as the internal standard (I.S.) was established using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). After alkalization with saturated sodium bicarbonate, plasma were extracted by ethyl acetate and separated by HPLC on a C18 reversed-phase column using a mobile phase of methanol-water-acetic acid-triethylamine (620:380:1.5:1.5, v/v). Analytes were quantitated using positive electrospray ionization in a quadrupole spectrometer. LC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at m/z 228 for tamsulosin and m/z 222 for the I.S. Calibration curves, which were linear over the range 0.2-30 ng/ml, were analyzed contemporaneously with each batch of samples, along with low (0.5 ng/ml), medium (3 ng/ml) and high (30 ng/ml) quality control samples. The intra- and inter-assay variability ranged from 2.14 to 8.87% for the low, medium and high quality control samples. The extraction recovery of tamsulosin from plasma was in the range of 84.2-94.5%. The method has been used successfully to study tamsulosin pharmacokinetics in adult humans.

  5. Specific determination of 20 primary aromatic amines in aqueous food simulants by liquid chromatography-electrospray ionization-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Mortensen, Sarah Kelly; Trier, Xenia Thorsager; Foverskov, Annie

    2005-01-01

    A multi-analyte method without any pre-treatment steps using reversed-phase liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was developed and applied for the determination of 20 primary aromatic amines (PAA) associated with polyurethane (PUR) products or azo...

  6. Identification and Quantification of the Major Constituents in Egyptian Carob Extract by Liquid Chromatography?Electrospray Ionization-Tandem Mass Spectrometry

    OpenAIRE

    Owis, Asmaa Ibrahim; El-Naggar, El-Motaz Bellah

    2016-01-01

    Background: Carob - Ceratonia siliqua L., commonly known as St John's-bread or locust bean, family Fabaceae - is one of the most useful native Mediterranean trees. There is no data about the chromatography methods performed by high performance liquid chromatography (HPLC) for determining polyphenols in Egyptian carob pods. Objective: To establish a sensitive and specific liquid chromatography?electrospray ionization (ESI)-tandem mass spectrometry (MSn) methodology for the identification of th...

  7. Identification of a tryptanthrin metabolite in rat liver microsomes by liquid chromatography/electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Lee, Sang Kyu; Kim, Ghee Hwan; Kim, Dong Hyeon; Kim, Dong Hyun; Jahng, Yurngdong; Jeong, Tae Cheon

    2007-10-01

    Tryptanthrin originally isolated from Isatis tinctoria L. has been characterized to have anti-inflammatory activities through the dual inhibition of cyclooxygenase-2 and 5-lipoxygenase mediated prostaglandin and leukotriene syntheses. To characterize phase I metabolite(s), tryptanthrin was incubated with rat liver microsomes in the presence of NADPH-generating system. One metabolite was identified by liquid chromatography/electrospray ionization-tandem mass spectrometry. M1 could be identified as a metabolite mono-hydroxylated on the aromatic ring of indole moiety from the MS(2) spectra of protonated tryptanthrin and M1. The structure of metabolite was confirmed as 8-hydroxytryptanthrin with a chemically synthesized authentic standard. The formation of M1 was NADPH-dependent and was inhibited by SKF-525A, a general CYP-inhibitor, indicating the cytochrome P450 (CYP)-mediated reaction. In addition, it was proposed that M1 might be formed by CYP 1A in rat liver microsomes from the experiments with enriched rat liver microsomes.

  8. Comparative analysis of Ligusticum chuanxiong and related umbelliferous medicinal plants by high performance liquid chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Yi, Tao; Leung, Kelvin Sze-Yin; Lu, Guang-Hua; Zhang, Hao

    2007-04-01

    A highly precise and accurate method, based on high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI-MS), was developed for the qualitative and quantitative comparison of the main constituents in the rhizome of Ligusticum chuanxiong (LC) and three related umbelliferous medicinal plants. A comprehensive validation of the developed method was conducted, and the method was highly sensitive, reproducible and accurate. The unique properties of the present method were validated by analyzing 20 related herbal samples including 5 LC samples, 5 Cnidium officinale samples (CO), 5 Angelica sinensis samples (AS) and 5 Angelica acutiloba samples (AA). Twelve compounds including phenolic constituents, alkylphthalides and phthalide dimers were identified by online ESI-MS and by comparison with literature data and standard compounds, and six of them were quantified by HPLC-DAD simultaneously. The results demonstrated that identical compound types were identified as the main constituents of LC, CO, AS and AA herbs. The results also support the alternative application of these medicinal plants in Chinese and Japanese folk medicines. In the present study, it was found that the variation in the abundance of senkyunolide A was significant in these related herbs; it is therefore feasible to choose senkyunolide A as a characteristic compound for quality evaluation and chemical authentication of these herbs.

  9. Separation and identification of corticosterone metabolites by liquid chromatography--electrospray ionization mass spectrometry.

    Science.gov (United States)

    Miksík, I; Vylitová, M; Pácha, J; Deyl, Z

    1999-04-16

    High-performance liquid chromatography coupled to atmospheric pressure ionization-electrospray ionization mass spectrometry (API-ESI-MS) was investigated for the analysis of corticosterone metabolites; their characterization was obtained by combining the separation on Zorbax Eclipse XDB C18 column (eluted with a methanol-water-acetic acid gradient) with identification using positive ion mode API-ESI-MS and selected ion analysis. The applicability of this method was verified by monitoring the activity of steroid converting enzymes (20beta-hydroxysteroid dehydrogenase and 11beta-hydroxysteroid dehydrogenase) in avian intestines.

  10. Simultaneous quantitative analysis of metabolites using ion-pair liquid chromatography-electrospray ionization mass spectrometry

    NARCIS (Netherlands)

    Coulier, L.; Bas, R.; Jespersen, S.; Verheij, E.; Werf, M.J. van der; Hankemeier, T.

    2006-01-01

    We have developed an analytical method, consisting of ion-pair liquid chromatography coupled to electrospray ionization mass spectrometry (IP-LC-ESI-MS), for the simultaneous quantitative analysis of several key classes of polar metabolites, like nucleotides, coenzyme A esters, sugar nucleotides,

  11. Application of liquid chromatography-electrospray ionization mass spectrometry for study of steroid-converting enzymes.

    Science.gov (United States)

    Miksík, Ivan; Mikulíková, Katerina; Pácha, Jirí; Kucka, Marek; Deyl, Zdenek

    2004-02-05

    A high-performance liquid chromatography-atmospheric pressure ionization-electrospray ionization mass spectrometry (HPLC-API-ESI-MS) method was developed for the analysis of steroids in a study of steroid-converting enzymes. Separations ware done on a Zorbax Eclipse XDB-C18 column (eluted with a linear methanol-water-acetic acid gradient) and identification of the steroids involved was done by API-ESI-MS using positive ion mode and extracted ion analysis. The applicability of the present method for studying steroid metabolism was proven in assaying two steroid-converting enzymes (20beta-hydroxysteroid dehydrogenase and 11beta-hydroxysteroid dehydrogenase) in various biological samples (rat and chicken intestine, chicken oviduct).

  12. Determination of clarithromycin in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Jiang, Yao; Wang, Jiang; Li, Hao; Wang, Yingwu; Gu, Jingkai

    2007-03-12

    A rapid and sensitive method has been developed for the determination of clarithromycin in human plasma with liquid chromatography-tandem mass spectrometry. Clarithromycin and the internal standard, telmisartan were precipitated from the matrix (50 microl) with 200 microl acetonitrile and separated by HPLC using formic acid:10 mM ammonium acetate:methanol (1:99:400, v/v/v) as the mobile phase. The assay based on detection by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring mode was finished within 2.4 min. Linearity was over the concentration range 10-5000 ng/ml with a limit of detection of 0.50 ng/ml. Intra- and inter-day precision measured as relative standard deviation were bioequivalence study of two tablet formulations of clarithromycin.

  13. Polymer Analysis by Liquid Chromatography/Electrospray Ionization Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Nielen, M W; Buijtenhuijs, F A

    1999-05-01

    Hyphenation of liquid chromatography (LC) techniques with electrospray ionization (ESI) orthogonal acceleration time-of-flight (oa-TOF) mass spectrometry (MS) provides both MS-based structural information and LC-based quantitative data in polymer analysis. In one experimental setup, three different LC modes are interfaced with MS:  size-exclusion chromatography (SEC/MS), gradient polymer elution chromatography (GPEC/MS), and liquid chromatography at the critical point of adsorption (LCCC/MS). In SEC/MS, both absolute mass calibration of the SEC column based on the polymer itself and determination of monomers and end groups from the mass spectra are achieved. GPEC/MS shows detailed chemical heterogeneity of the polymer and the chemical composition distribution within oligomer groups. In LCCC/MS, the retention behavior is primarily governed by chemical heterogeneities, such as different end group functionalities, and quantitative end group calculations can be easily made. The potential of these methods and the benefit of time-of-flight analyzers in polymer analysis are discussed using SEC/MS of a polydisperse poly(methyl methacrylate) sample, GPEC/MS of dipropoxylated bisphenol A/adipic acid polyester resin, LCCC/MS of alkylated poly(ethylene glycol), and LCCC/MS of terephthalic acid/neopentyl glycol polyester resin.

  14. Determination of flomoxef in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Kravtsova, Oxana Yu; Paramonov, Sergey A; Vasilevich, Natalya I; Kazyulkin, Denis N; Vlasova, Ekaterina; Engsig, Michael

    2013-12-01

    A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high-performance liquid chromatography-tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative-ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μM, 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10-5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra- and inter-day precisions were flomoxef revealed that it could be successfully analyzed at 4 ºС over 24 h, but it was unstable in solutions at room temperature during short-term storage (4 h) and several freeze-thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Analysis of selected antibiotics in surface freshwater and seawater using direct injection in liquid chromatography electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Bayen, Stéphane; Yi, Xinzhu; Segovia, Elvagris; Zhou, Zhi; Kelly, Barry C

    2014-04-18

    Emerging contaminants such as antibiotics have received recent attention as they have been detected in natural waters and health concerns over potential antibiotic resistance. With the purpose to investigate fast and high-throughput analysis, and eventually the continuous on-line analysis of emerging contaminants, this study presents results on the analysis of seven selected antibiotics (sulfadiazine, sulfamethazine, sulfamerazine, sulfamethoxazole, chloramphenicol, lincomycin, tylosin) in surface freshwater and seawater using direct injection of a small sample volume (20μL) in liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Notably, direct injection of seawater in the LC-ESI-MS/MS was made possible on account of the post-column switch on the system, which allows diversion of salt-containing solutions flushed out of the column to the waste. Mean recoveries based on the isotope dilution method average 95±14% and 96±28% amongst the compounds for spiked freshwater and seawater, respectively. Linearity across six spiking levels was assessed and the response was linear (r(2)>0.99) for all compounds. Direct injection concentrations were compared for real samples to those obtained with the conventional SPE-based analysis and both techniques concurs on the presence/absence and levels of the compounds in real samples. These results suggest direct injection is a reliable method to detect antibiotics in both freshwater and seawater. Method detection limits for the direct injection technique (37pg/L to 226ng/L in freshwater, and from 16pg/to 26ng/L in seawater) are sufficient for a number of environmental applications, for example the fast screening of water samples for ecological risk assessments. In the present study of real samples, this new method allowed for example the positive detection of some compounds (e.g. lincomycin) down to the sub ng/L range. The direct injection method appears to be relatively cheaper and faster

  16. Investigation of pyrrolizidine alkaloids and their N-oxides in commercial comfrey-containing products and botanical materials by liquid chromatography electrospray ionization mass spectrometry.

    Science.gov (United States)

    Altamirano, Jorgelina C; Gratz, Samuel R; Wolnik, Karen A

    2005-01-01

    Pyrrolizidine alkaloids (PAs) and their N-oxides are found in several plant families throughout the world. PAs are potentially toxic to the liver and/or lungs in humans and may cause acute liver failure, cirrhosis, pneumonitis, or pulmonary hypertension. PAs are also carcinogenic to animals, and they have been linked to the development of hepatocellular and skin squamous cell carcinomas as well as liver angiosarcomas. According to experimental studies, the quantity of PAs in some herbal teas and dietary supplements is sufficient to be carcinogenic in exposed individuals. A method for the extraction and identification of PAs and their N-oxides in botanical materials and commercial comfrey-containing products has been developed using liquid chromatography electrospray ionization mass spectrometry. Following optimization of the extraction procedure and the chromatographic conditions, the method was applied to the analysis of 10 herbal remedies. All of the products that were labeled to contain comfrey were found to contain measurable quantities of PAs.

  17. Rapid Screening and Characterization of Acetylcholinesterase Inhibitors from Yinhuang Oral Liquid Using Ultrafiltration-liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry.

    Science.gov (United States)

    Zhang, Haomin; Guo, Yinan; Meng, Lingwen; Sun, Hui; Yang, Yinping; Gao, Ying; Sun, Jiaming

    2018-01-01

    At present, approximately 17-25 million people in the world suffer from Alzheimer's disease (AD). The most efficacious and acceptable therapeutic drug clinically are the acetylcholinesterase inhibitors (AChEIs). Yinhuang oral liquid is a Chinese medicine preparation which contains AChEIs according to the literatures. However, no strategy has been presented for rapid screening and identification of AChEIs from Yinhuang oral liquid. To develop a method for rapid screening and identification of AChEIs from Yinhuang oral liquid using ultrafiltration-liquid chromatography-electrospray ionization tandem mass spectrometry (UF-LC-ESI-MS/MS). In this study, UF incubation conditions such as enzyme concentration, incubation time, and incubation temperature were optimized so as to get better screening results. The AChEIs from Yinhuang oral liquid were identified by high-performance liquid chromatography-ESI-MS and the improved Ellman method was used for the AChE inhibitory activity test in vitro . The results showed that Yinhuang oral liquid can inhibit the activity of AChE. We screened and identified seven compounds with potential AChE inhibitory activity from Yinhuang oral liquid, which provided experimental basis for the treatment and prevention of AD. The current technique was used to directly screen the active ingredients with acetylcholinesterase inhibition from complex traditional Chinese medicine, which was simple, rapid, accurate, and suitable for high-throughput screening of AChEI from complex systems. A UF-LC-ESI-MS/MS method for rapid screening and identification of AChEIs from Yinhuang oral liquid was developedSeven compounds were screened and identified with potential AChE inhibitory activity from Yinhuang oral liquidIt provided experimental basis of Yinhuang oral liquid for the treating and preventing AD. Abbreviations used: (AD): Alzheimer's disease; (UF-LC-ESI-MS/MS): ultrafiltration-liquid chromatography-electrospray ionization tandem mass spectrometry; (ACh

  18. Characterization of Proanthocyanidins from Parkia biglobosa (Jacq. G. Don. (Fabaceae by Flow Injection Analysis — Electrospray Ionization Ion Trap Tandem Mass Spectrometry and Liquid Chromatography/Electrospray Ionization Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Wagner Vilegas

    2013-03-01

    Full Text Available The present study investigates the chemical composition of the African plant Parkia biglobosa (Fabaceae roots and barks by Liquid Chromatography - Electrospray Ionization and Direct Injection Tandem Mass Spectrometry analysis. Mass spectral data indicated that B-type oligomers are present, namely procyanidins and prodelphinidins, with their gallate and glucuronide derivatives, some of them in different isomeric forms. The analysis evidenced the presence of up to 40 proanthocyanidins, some of which are reported for the first time. In this study, the antiradical activity of extracts of roots and barks from Parkia biglobosa was evaluated using DPPH method and they showed satisfactory activities.

  19. Pharmacokinetic Study of a Diclofenac Sodium Capsule Filled with Enteric-coated Pellets in Healthy Chinese Volunteers by Liquid Chromatography-electrospray Ionization-tandem Mass Spectrometry.

    Science.gov (United States)

    Ma, J-Y; Liu, M; Yang, M; Zhao, H; Tong, Y; Zhang, Y; Deng, M; Liu, H

    2016-05-01

    The pharmacokinetic study of a diclofenac sodium capsule filled with enteric-coated pellets (abbreviated as CAPSULE) in healthy Chinese subjects was evaluated using liquid chromatography-electrospray ionization-tandem mass spectrometry with simple sample preparation. In a cross-over study, 12 healthy male volunteers were given 50 mg CAPSULE and diclofenac sodium enteric-coated tablet (abbreviated as TABLET, used as a control dosage form) at fasting. The Cmax, AUC0-t, and Tmax of CAPSULE were 1.01±0.52 μg/mL, 1.54±0.18 μg·h/mL, and 1.50±1.31 h, respectively. When compared with TABLET, the pharmacokinetic study showed that although this CAPSULE exhibited similar AUC (only 10% lower), it presented lower maximum plasma concentration, faster absorption and shorter time to reach maximum concentration. When compared with the previous study in Germany, obvious variations on Tmax were found in Chinese subjects taking CAPSULE, but not TABLET. The results indicated that individual difference should be paid attention when prescribing CAPSULE to Chinese patients. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Ultra high performance liquid chromatography-electrospray ionization-tandem mass spectrometry screening method for direct analysis of designer drugs, "spice" and stimulants in oral fluid.

    Science.gov (United States)

    Strano-Rossi, Sabina; Anzillotti, Luca; Castrignanò, Erika; Romolo, Francesco Saverio; Chiarotti, Marcello

    2012-10-05

    An ultra high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS) screening method for the direct analysis in oral fluid (OF) of 24 drugs, including new synthetic cannabinoids and so-called "smart" designer drugs, in a single chromatographic run was set up. Benzylpiperazine, methylone, 5,6-methylenedioxy-2-aminoindane (MDAI), fenproporex, 4-fluoroamphetamine (4-FA), 4-methyl-N-ethylcathinone (4-MEC), 4-methylamphetamine (4-MA), methylbenzodioxolylbutanamine (MBDB), mephedrone, methylthioamphetamine (MTA), methylenedioxypyrovalerone (MDPV), mefenorex, nabilone, furfenorex, clobenzorex, JWH-200, AM 694, JWH-250, JWH-073, JWH-018, JWH-019, JWH-122, HU 210 and CP 47497 were determined in a chromatographic run of 9 min only with no sample pre-treatment, after addition of ISs and dilution in mobile phase A. This method is designed to be applied to 250 μL of OF sample, anyway is suitable to be used on smaller volumes (till 100 μL). LODs vary from 1ng/mL to 20 ng/mL. No interfering peaks were observed due to similar analytes, common therapeutic drugs or endogenous compounds. Matrix effect, although present especially for mephedrone, is acceptable, allowing the detection of the compounds at the LODs described. The developed method was applied on 400 real OF samples from on-site tests performed by police officers. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. A simple and selective method for the measurement of azadirachtin and related azadirachtoid levels in fruits and vegetables using liquid chromatography electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Sarais, Giorgia; Caboni, Pierluigi; Sarritzu, Erika; Russo, Mariateresa; Cabras, Paolo

    2008-05-14

    Neem-based insecticides containing azadirachtin and related azadirachtoids are widely used in agriculture. Here, we report an analytical method for the rapid and accurate quantification of the insecticide azadirachtin A and B and other azadirachtoids such as salannin, nimbin, and their deacetylated analogues on tomatoes and peaches. Azadirachtoids were extracted from fruits and vegetables with acetonitrile. Using high-performance liquid chromatography/electrospray ionization tandem mass spectrometer, azadirachtoids were selectively detected monitoring the multiple reaction transitions of sodium adduct precursor ions. For azadirachtin A, calibration was linear over a working range of 1-1000 microg/L with r > 0.996. The limit of detection and limit of quantification for azadirachtin A were 0.4 and 0.8 microg/kg, respectively. The presence of interfering compounds in the peach and tomato extracts was evaluated and found to be minimal. Because of the linear behavior, it was concluded that the multiple reaction transitions of sodium adduct ions can be used for analytical purposes, that is, for the identification and quantification of azadirachtin A and B and related azadirachtoids in fruit and vegetable extracts at trace levels.

  2. Determination of selected antibiotics in the Victoria Harbour and the Pearl River, South China using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry

    International Nuclear Information System (INIS)

    Xu Weihai; Zhang Gan; Zou Shichun; Li Xiangdong; Liu Yuchun

    2007-01-01

    Nine selected antibiotics in the Victoria Harbour of Hong Kong and the Pearl River at Guangzhou, South China, were analyzed using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry. The results showed that the concentrations of antibiotics were mainly below the limit of quantification (LOQ) in the marine water of Victoria Harbour. However, except for amoxicillin, all of the antibiotics were detected in the Pearl River during high and low water seasons with the median concentrations ranging from 11 to 67 ng/L, and from 66 to 460 ng/L, respectively; and the concentrations in early spring were about 2-15 times higher than that in summer with clearer diurnal variations. It was suggested that the concentrations of antibiotics in the high water season were more affected by wastewater production cycles due to quick refreshing rate, while those in the low water season may be more sensitive to the water column dynamics controlled by tidal processes in the river. - Antibiotics were found at high concentrations in an urban reach of Pearl River in southern China with contrast diurnal variations between the high and low water seasons

  3. Direct analysis of psychoactive tryptamine and harmala alkaloids in the Amazonian botanical medicine ayahuasca by liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    McIlhenny, Ethan H; Pipkin, Kelly E; Standish, Leanna J; Wechkin, Hope A; Strassman, Rick; Barker, Steven A

    2009-12-18

    A direct injection/liquid chromatography-electrospray ionization-tandem mass spectrometry procedure has been developed for the simultaneous quantitation of 11 compounds potentially found in the increasingly popular Amazonian botanical medicine and religious sacrament ayahuasca. The method utilizes a deuterated internal standard for quantitation and affords rapid detection of the alkaloids by a simple dilution assay, requiring no extraction procedures. Further, the method demonstrates a high degree of specificity for the compounds in question, as well as low limits of detection and quantitation despite using samples for analysis that had been diluted up to 200:1. This approach also appears to eliminate potential matrix effects. Method bias for each compound, examined over a range of concentrations, was also determined as was inter- and intra-assay variation. Its application to the analysis of three different ayahuasca preparations is also described. This method should prove useful in the study of ayahuasca in clinical and ethnobotanical research as well as in forensic examinations of ayahuasca preparations.

  4. Investigation of natural phosphatidylcholine sources: separation and identification by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS2) of molecular species.

    Science.gov (United States)

    Le Grandois, Julie; Marchioni, Eric; Zhao, Minjie; Giuffrida, Francesca; Ennahar, Saïd; Bindler, Françoise

    2009-07-22

    This study is a contribution to the exploration of natural phospholipid (PL) sources rich in long-chain polyunsaturated fatty acids (LC-PUFAs) with nutritional interest. Phosphatidylcholines (PCs) were purified from total lipid extracts of different food matrices, and their molecular species were separated and identified by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS(2)). Fragmentation of lithiated adducts allowed for the identification of fatty acids linked to the glycerol backbone. Soy PC was particularly rich in species containing essential fatty acids, such as (18:2-18:2)PC (34.0%), (16:0-18:2)PC (20.8%), and (18:1-18:2)PC (16.3%). PC from animal sources (ox liver and egg yolk) contained major molecular species, such as (16:0-18:2)PC, (16:0-18:1)PC, (18:0-18:2)PC, or (18:0-18:1)PC. Finally, marine source (krill oil), which was particularly rich in (16:0-20:5)PC and (16:0-22:6)PC, appeared to be an interesting potential source for food supplementation with LC-PUFA-PLs, particularly eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA).

  5. Liquid chromatography-electrospray ionization tandem mass spectrometry and dynamic multiple reaction monitoring method for determining multiple pesticide residues in tomato.

    Science.gov (United States)

    Andrade, G C R M; Monteiro, S H; Francisco, J G; Figueiredo, L A; Botelho, R G; Tornisielo, V L

    2015-05-15

    A quick and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method, using dynamic multiple reaction monitoring and a 1.8-μm particle size analytical column, was developed to determine 57 pesticides in tomato in a 13-min run. QuEChERS (quick, easy, cheap, effective, rugged, and safe) method for samples preparations and validations was carried out in compliance with EU SANCO guidelines. The method was applied to 58 tomato samples. More than 84% of the compounds investigated showed limits of detection equal to or lower than 5 mg kg(-1). A mild (50%) matrix effect was observed for 72%, 25%, and 3% of the pesticides studied, respectively. Eighty-one percent of the pesticides showed recoveries ranging between 70% and 120%. Twelve pesticides were detected in 35 samples, all below the maximum residue levels permitted in the Brazilian legislation; 15 samples exceeded the maximum residue levels established by the EU legislation for methamidophos; and 10 exceeded limits for acephate and four for bromuconazole. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Characterization and identification of iridoid glucosides, flavonoids and anthraquinones in Hedyotis diffusa by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Liu, E-Hu; Zhou, Ting; Li, Guo-Bin; Li, Jing; Huang, Xiu-Ning; Pan, Feng; Gao, Ning

    2012-01-01

    The multiple bioactive constituents in Hedyotis diffusa Willd. (H. diffusa) were extracted and characterized by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC-ESI-MS(n)). The optimized separation condition was obtained using an Agilent ZorBax SB-C18 column (4.6×150 mm, 5 μm) and gradient elution with water (containing 0.1% formic acid) and acetonitrile (containing 0.1% formic acid), under which baseline separation for the majority of compounds was achieved. Among the compounds detected, 14 iridoid glucosides, 10 flavonoids, 7 anthraquinones, 1 coumarin and 1 triterpene were unambiguously identified or tentatively characterized based on their retention times and mass spectra in comparison with the data from standards or references. The fragmentation behavior for different types of constituents was also investigated, which could contribute to the elucidation of these constituents in H. diffusa. The present study reveals that even more iridoid glycosides were found in H. diffusa than hitherto assumed. The occurrence of two iridoid glucosides and five flavonoids in particular has not yet been described. This paper marks the first report on the structural characterization of chemical compounds in H. diffusa by a developed HPLC-ESI-MS(n) method. Copyright © 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Capillary column switching restricted-access media-liquid chromatography-electrospray ionization-tandem mass spectrometry system for simultaneous and direct analysis of drugs in biofluids.

    Science.gov (United States)

    Santos-Neto, Alvaro J; Markides, Karin E; Sjöberg, Per J R; Bergquist, Jonas; Lancas, Fernando M

    2007-08-15

    Capillary online restricted-access media-liquid chromatography-electrospray ionization-tandem mass spectrometry (RAM-LC-ESI-MS/MS) for direct analysis of drugs and metabolites spiked in biological fluids was developed. Using a column switching setup it was possible to perform effective sample preparation and analysis of raw biological fluids (plasma and urine) without matrix effects in the electrospray mass spectrometric detection step. The peak focusing efficiency of the extraction column was more effective in backflush compared to foreflush mode. The system was able to concentrate diminished samples of polar drugs and their metabolites reaching quantifiable results as low as 1 ng/mL utilizing a sample volume of only 333 nL of biofluids. New column hardware was developed to circumvent clogging problems experienced with plasma injections. The glass fiber filter frit, which is commonly used, was replaced with a short piece of 20 microm i.d. fused silica capillary. The extraction columns were able to handle up to 60 injections and showed a high loading capacity, making the saturation of the MS detector the limiting factor on the linear dynamic range. The simultaneous separation and detection of 10 drugs and metabolites was obtained in 8 min of analysis, including the online sample preparation and enrichment step.

  8. Quantitative analysis of glycosaminoglycans, chondroitin/dermatan sulfate, hyaluronic acid, heparan sulfate, and keratan sulfate by liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Osago, Harumi; Shibata, Tomoko; Hara, Nobumasa; Kuwata, Suguru; Kono, Michihaya; Uchio, Yuji; Tsuchiya, Mikako

    2014-12-15

    We developed a method using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) with a selected reaction monitoring (SRM) mode for simultaneous quantitative analysis of glycosaminoglycans (GAGs). Using one-shot analysis with our MS/MS method, we demonstrated the simultaneous quantification of a total of 23 variously sulfated disaccharides of four GAG classes (8 chondroitin/dermatan sulfates, 1 hyaluronic acid, 12 heparan sulfates, and 2 keratan sulfates) with a sensitivity of less than 0.5 pmol within 20 min. We showed the differences in the composition of GAG classes and the sulfation patterns between porcine articular cartilage and yellow ligament. In addition to the internal disaccharides described above, some saccharides derived from the nonreducing terminal were detected simultaneously. The simultaneous quantification of both internal and nonreducing terminal saccharides could be useful to estimate the chain length of GAGs. This method would help to establish comprehensive "GAGomic" analysis of biological tissues. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Quantification of piperazine phosphate in human plasma by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry employing precolumn derivatization with dansyl chloride.

    Science.gov (United States)

    Lin, Hui; Tian, Yuan; Zhang, Zunjian; Wu, Lili; Chen, Yun

    2010-04-01

    This paper describes a novel method that combines dansyl chloride (DNS-CL) derivatization with high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) for the sensitive and selective determination of piperazine phosphate in human plasma. After addition of ondansetron hydrochloride as internal standard (IS), piperazine phosphate was derivatized and then extracted with ethyl acetate. After being evaporated and reconstituted, the sample was analyzed using LC-ESI/MS/MS. Separation was achieved using an Agilent ZORBAX SB-C(18) (150 mm x 2.1 mm I.D., 3.5 microm) column and isocratic elution with 10 mM ammonium acetate solution (pH 3.0)-methanol (50: 50, v/v). Detection was performed on a triple-quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 320-->171 for DNS-CL-piperazine phosphate and m/z 294-->170 for the IS. The method was fully validated for its selectivity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability. The coefficient (r) of piperazine phosphate with a linear range of 0.1-15 microg mL(-1) was 0.9974-0.9995. The limit of detection and lower limit of quantification in human plasma were 0.01 and 0.1 microg mL(-1), respectively. The validated LC-ESI/MS/MS method has been successfully applied to a bioequivalence study of piperazine phosphate trochiscus in Chinese healthy male volunteers. 2010 Elsevier B.V. All rights reserved.

  10. Determination of short chain carboxylic acids in vegetable oils and fats using ion exclusion chromatography electrospray ionization mass spectrometry.

    Science.gov (United States)

    Viidanoja, Jyrki

    2015-02-27

    A new method for quantification of short chain C1-C6 carboxylic acids in vegetable oils and fats by employing Liquid Chromatography Mass Spectrometry (LC-MS) has been developed. The method requires minor sample preparation and applies non-conventional Electrospray Ionization (ESI) liquid phase chemistry. Samples are first dissolved in chloroform and then extracted using water that has been spiked with stable isotope labeled internal standards that are used for signal normalization and absolute quantification of selected acids. The analytes are separated using Ion Exclusion Chromatography (IEC) and detected with Electrospray Ionization Mass Spectrometry (ESI-MS) as deprotonated molecules. Prior to ionization the eluent that contains hydrochloric acid is modified post-column to ensure good ionization efficiency of the analytes. The averaged within run precision and between run precision were generally lower than 8%. The accuracy was between 85 and 115% for most of the analytes. The Lower Limit of Quantification (LLOQ) ranged from 0.006 to 7mg/kg. It is shown that this method offers good selectivity in cases where UV detection fails to produce reliable results. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. CHARACTERIZATION OF DANSYLATED CYSTEINE, CYSTINE, GLUTATHIONE, AND GLUTATHIONE DISULFIDE BY NARROW BORE LIQUID CHROMATOGRAPHY - ELECTROSPRAY IONIZATION MASS SPECTROMETRY

    Science.gov (United States)

    A method using reversed phase high performance liquid chromtography/electrospray ionization-mass spectrometry (RP-LC/ESI-MS) has been developed to confirm the dientity of dansylated derivatives of cysteine (C) and glutathione (GSH), and their respective dimers, cystine (CSSC) and...

  12. Ultrahigh-performance liquid chromatography electrospray ionization Q-Orbitrap mass spectrometry for the analysis of 451 pesticide residues in fruits and vegetables: method development and validation.

    Science.gov (United States)

    Wang, Jian; Chow, Willis; Chang, James; Wong, Jon W

    2014-10-22

    This paper presents an application of ultrahigh-performance liquid chromatography electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap MS) for the determination of 451 pesticide residues in fruits and vegetables. Pesticides were extracted from samples using the QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure. UHPLC/ESI Q-Orbitrap MS in full MS scan mode acquired full MS data for quantification, and UHPLC/ESI Q-Orbitrap Full MS/dd-MS(2) (i.e., data-dependent scan mode) obtained product ion spectra for identification. UHPLC/ESI Q-Orbitrap MS quantification was achieved using matrix-matched standard calibration curves along with the use of isotopically labeled standards or a chemical analogue as internal standards to achieve optimal method accuracy. The method performance characteristics include overall recovery, intermediate precision, and measurement uncertainty evaluated according to a nested experimental design. For the 10 matrices studied, 94.5% of the pesticides in fruits and 90.7% in vegetables had recoveries between 81 and 110%; 99.3% of the pesticides in fruits and 99.1% of the pesticides in vegetables had an intermediate precision of ≤20%; and 97.8% of the pesticides in fruits and 96.4% of the pesticides in vegetables showed measurement uncertainty of ≤50%. Overall, the UHPLC/ESI Q-Orbitrap MS demonstrated acceptable performance for the quantification of pesticide residues in fruits and vegetables. The UHPLC/ESI Q-Orbitrap Full MS/dd-MS(2) along with library matching showed great potential for identification and is being investigated further for routine practice.

  13. Development of a method for comprehensive and quantitative analysis of plant hormones by highly sensitive nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry

    International Nuclear Information System (INIS)

    Izumi, Yoshihiro; Okazawa, Atsushi; Bamba, Takeshi; Kobayashi, Akio; Fukusaki, Eiichiro

    2009-01-01

    In recent plant hormone research, there is an increased demand for a highly sensitive and comprehensive analytical approach to elucidate the hormonal signaling networks, functions, and dynamics. We have demonstrated the high sensitivity of a comprehensive and quantitative analytical method developed with nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-IT-MS/MS) under multiple-reaction monitoring (MRM) in plant hormone profiling. Unlabeled and deuterium-labeled isotopomers of four classes of plant hormones and their derivatives, auxins, cytokinins (CK), abscisic acid (ABA), and gibberellins (GA), were analyzed by this method. The optimized nanoflow-LC-ESI-IT-MS/MS method showed ca. 5-10-fold greater sensitivity than capillary-LC-ESI-IT-MS/MS, and the detection limits (S/N = 3) of several plant hormones were in the sub-fmol range. The results showed excellent linearity (R 2 values of 0.9937-1.0000) and reproducibility of elution times (relative standard deviations, RSDs, <1.1%) and peak areas (RSDs, <10.7%) for all target compounds. Further, sample purification using Oasis HLB and Oasis MCX cartridges significantly decreased the ion-suppressing effects of biological matrix as compared to the purification using only Oasis HLB cartridge. The optimized nanoflow-LC-ESI-IT-MS/MS method was successfully used to analyze endogenous plant hormones in Arabidopsis and tobacco samples. The samples used in this analysis were extracted from only 17 tobacco dry seeds (1 mg DW), indicating that the efficiency of analysis of endogenous plant hormones strongly depends on the detection sensitivity of the method. Our analytical approach will be useful for in-depth studies on complex plant hormonal metabolism.

  14. Development of a method for comprehensive and quantitative analysis of plant hormones by highly sensitive nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Izumi, Yoshihiro; Okazawa, Atsushi; Bamba, Takeshi; Kobayashi, Akio [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan); Fukusaki, Eiichiro, E-mail: fukusaki@bio.eng.osaka-u.ac.jp [Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2009-08-26

    In recent plant hormone research, there is an increased demand for a highly sensitive and comprehensive analytical approach to elucidate the hormonal signaling networks, functions, and dynamics. We have demonstrated the high sensitivity of a comprehensive and quantitative analytical method developed with nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-IT-MS/MS) under multiple-reaction monitoring (MRM) in plant hormone profiling. Unlabeled and deuterium-labeled isotopomers of four classes of plant hormones and their derivatives, auxins, cytokinins (CK), abscisic acid (ABA), and gibberellins (GA), were analyzed by this method. The optimized nanoflow-LC-ESI-IT-MS/MS method showed ca. 5-10-fold greater sensitivity than capillary-LC-ESI-IT-MS/MS, and the detection limits (S/N = 3) of several plant hormones were in the sub-fmol range. The results showed excellent linearity (R{sup 2} values of 0.9937-1.0000) and reproducibility of elution times (relative standard deviations, RSDs, <1.1%) and peak areas (RSDs, <10.7%) for all target compounds. Further, sample purification using Oasis HLB and Oasis MCX cartridges significantly decreased the ion-suppressing effects of biological matrix as compared to the purification using only Oasis HLB cartridge. The optimized nanoflow-LC-ESI-IT-MS/MS method was successfully used to analyze endogenous plant hormones in Arabidopsis and tobacco samples. The samples used in this analysis were extracted from only 17 tobacco dry seeds (1 mg DW), indicating that the efficiency of analysis of endogenous plant hormones strongly depends on the detection sensitivity of the method. Our analytical approach will be useful for in-depth studies on complex plant hormonal metabolism.

  15. Simultaneous determination of water-soluble vitamins in selected food matrices by liquid chromatography/electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Gentili, Alessandra; Caretti, Fulvia; D'Ascenzo, Giuseppe; Marchese, Stefano; Perret, Daniela; Di Corcia, Daniele; Rocca, Lucia Mainero

    2008-07-01

    A rapid, simple and sensitive method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) with an electrospray ionization (ESI) source for the simultaneous analysis of fourteen water-soluble vitamins (B1, B2, two B3 vitamers, B5, five B6 vitamers, B8, B9, B12 and C) in various food matrices, i.e. maize flour, green and golden kiwi and tomato pulp, is presented here. Analytes were separated by ion-suppression reversed-phase liquid chromatography in less than 10 min and detected in positive ion mode. Sensitivity and specificity of this method allowed two important results to be achieved: (i) limits of detection of the analytes at ng g(-1) levels (except for vitamin C); (ii) development of a rapid sample treatment that minimizes analyte exposition to light, air and heat, eliminating any step of extract concentration. Analyte recovery depended on the type of matrix. In particular, recovery of the analytes in maize flour was > or =70%, with the exception of vitamin C, pyridoxal-5'-phosphate and vitamin B9 (ca 40%); with tomato pulp, recovery was > or =64%, except for vitamin C (41%); with kiwi, recovery was > or =73%, except for nicotinamide (ca. 30%).

  16. Simultaneous determination of antiretroviral drugs in human hair with liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Wu, Yan; Yang, Jin; Duan, Cailing; Chu, Liuxi; Chen, Shenghuo; Qiao, Shan; Li, Xiaoming; Deng, Huihua

    2018-04-15

    The determination of the concentrations of antiretroviral drugs in hair is believed to be an important means for the assessment of the long-term adherence to highly active antiretroviral therapy. At present, the combination of tenofovir, lamivudine and nevirapine is widely used in China. However, there was no research reporting simultaneous determination of the three drugs in hair. The present study aimed to develop a sensitive method for simultaneous determination of the three drugs in 2-mg and 10-mg natural hair (Method 1 and Method 2). Hair samples were incubated in methanol at 37 °C for 16 h after being rinsed with methanol twice. The analysis was performed on high performance liquid chromatography tandem mass spectrometry with electronic spray ionization in positive mode and multiple reactions monitoring. Method 1 and Method 2 showed the limits of detection at 160 and 30 pg/mg for tenofovir, at 5 and 6 pg/mg for lamivudine and at 15 and 3 pg/mg for nevirapine. The two methods showed good linearity with the square of correlation coefficient >0.99 at the ranges of 416-5000 and 77-5000 pg/mg for tenofovir, 12-5000 and 15-5000 pg/mg for lamivudine and 39-50,000 and 6-50,000 pg/mg for nevirapine. They gave intra-day and inter-day coefficient of variation <15% and the recoveries ranging from 80.6 to 122.3% and from 83.1 to 114.4%. Method 2 showed LOD and LOQ better than Method 1 for tenofovir and nevirapine and matched Method 1 for lamivudine, but there was high consistency between them in the determination of the three drugs in hair. The population analysis with Method 2 revealed that the concentrations in hair were decreased with the distance of hair segment away from the scalp for the three antiretroviral drugs. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Investigation of plant hormone level changes in shoot tips of longan (Dimocarpus longan Lour.) treated with potassium chlorate by liquid chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Susawaengsup, Chanthana; Rayanakorn, Mongkon; Wongpornchai, Sugunya; Wangkarn, Sunanta

    2011-08-15

    The endogenous levels of indole-3-acetic acid (IAA), gibberellins (GAs), abscisic acid (ABA) and cytokinins (CKs) and their changes were investigated in shoot tips of ten longan (Dimocarpus longan Lour.) trees for off-season flowering until 60 days after potassium chlorate treatment in comparison with those of ten control (untreated) longan trees. These analytes were extracted and interfering matrices removed with a single mixed-mode solid phase extraction under optimum conditions. The recoveries at three levels of concentration were in the range of 72-112%. The endogenous plant hormones were separated and quantified by liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). Detection limits based on the signal-to-noise ratio ranged from 10 ng mL(-1) for gibberellin A4 (GA4) to 200 ng mL(-1) for IAA. Within the first week after potassium chlorate treatment, dry weight (DW) amounts in the treated longan shoot tips of four gibberellins, namely: gibberellin A1(GA1), gibberellic acid (GA3), gibberellin A19 (GA19) and gibberellin A20 (GA20), were found to increase to approximately 25, 50, 20 and 60 ng g(-1) respectively, all of which were significantly higher than those of the controls. In contrast, gibberellin A8 (GA8) obtained from the treated longan was found to decrease to approximately 20 ng g(-1)DW while that of the control increased to around 80 ng g(-1)DW. Certain CKs which play a role in leaf bud induction, particularly isopentenyl adenine (iP), isopentenyl adenosine (iPR) and dihydrozeatin riboside (DHZR), were found to be present in amounts of approximately 20, 50 and 60 ng g(-1)DW in the shoot tips of the control longan. The analytical results obtained from the two-month off-season longan flowering period indicate that high GA1, GA3, GA19 and GA20 levels in the longan shoot tips contribute to flower bud induction while high levels of CKs, IAA and ABA in the control longan contribute more to the vegetative development. Copyright © 2011

  18. Quantitation of 13 heterocyclic aromatic amines in cooked beef, pork, and chicken by liquid chromatography-electrospray ionization/tandem mass spectrometry.

    Science.gov (United States)

    Ni, Weijuan; McNaughton, Lynn; LeMaster, David M; Sinha, Rashmi; Turesky, Robert J

    2008-01-09

    The concentrations of heterocyclic aromatic amines (HAAs) were determined, by liquid chromatography-electrospray ionization/tandem mass spectrometry (LC-ESI-MS/MS), in 26 samples of beef, pork, and chicken cooked to various levels of doneness. The HAAs identified were 2-amino-3-methylimidazo[4,5- f]quinoline, 2-amino-1-methylimidazo[4,5- b]quinoline, 2-amino-1-methylimidazo[4,5- g]quinoxaline (I gQx), 2-amino-3-methylimidazo[4,5- f]quinoxaline, 2-amino-1,7-dimethylimidazo[4,5- g]quinoxaline (7-MeI gQx), 2-amino-3,8-dimethylimidazo[4,5- f]quinoxaline, 2-amino-1,6-dimethyl-furo[3,2- e]imidazo[4,5- b]pyridine, 2-amino-1,6,7-trimethylimidazo[4,5- g]quinoxaline, 2-amino-3,4,8-trimethylimidazo[4,5- f]quinoxaline, 2-amino-1,7,9-trimethylimidazo[4,5- g]quinoxaline, 2-amino-1-methyl-6-phenylimidazo[4,5- b]pyridine (PhIP), 2-amino-9 H-pyrido[2,3- b]indole, and 2-amino-3-methyl-9 H-pyrido[2,3- b]indole. The concentrations of these compounds ranged from chicken (up to 305 microg/kg), broiled bacon (16 microg/kg), and pan-fried bacon (4.9 microg/kg). 7-MeI gQx was the most abundant HAA formed in very well done pan-fried beef and steak, and in beef gravy, at concentrations up to 30 microg/kg. Several other linear tricyclic ring HAAs containing the I gQx skeleton are formed at concentrations in cooked meats that are relatively high in comparison to the concentrations of their angular tricyclic ring isomers, the latter of which are known experimental animal carcinogens and potential human carcinogens. The toxicological properties of these recently discovered I gQx derivatives warrant further investigation and assessment.

  19. A simple and selective method for determination of phthalate biomarkers in vegetable samples by high pressure liquid chromatography-electrospray ionization-tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Xi; Cui, Kunyan; Zeng, Feng; Li, Shoucong; Zeng, Zunxiang

    2016-06-01

    In the present study, solid-phase extraction cartridges including silica reversed-phase Isolute C18, polymeric reversed-phase Oasis HLB and mixed-mode anion-exchange Oasis MAX, and liquid-liquid extractions with ethyl acetate, n-hexane, dichloromethane and its mixtures were compared for clean-up of phthalate monoesters from vegetable samples. Best recoveries and minimised matrix effects were achieved using ethyl acetate/n-hexane liquid-liquid extraction for these target compounds. A simple and selective method, based on sample preparation by ultrasonic extraction and liquid-liquid extraction clean-up, for the determination of phthalate monoesters in vegetable samples by liquid chromatography/electrospray ionisation-tandem mass spectrometry was developed. The method detection limits for phthalate monoesters ranged from 0.013 to 0.120 ng g(-1). Good linearity (r(2)>0.991) between MQLs and 1000× MQLs was achieved. The intra- and inter-day relative standard deviation values were less than 11.8%. The method was successfully used to determine phthalate monoester metabolites in the vegetable samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Development of a liquid chromatography-electrospray chemical ionization tandem mass spectrometry analytical method for analysis of eleven hydroxylated polybrominated diphenyl ethers.

    Science.gov (United States)

    Feo, Maria Luisa; Barón, Enrique; Aga, Diana S; Eljarrat, Ethel; Barceló, Damià

    2013-08-02

    Recently, hydroxylated polybrominated diphenyl ethers (OH-PBDEs) have emerged as environmentally relevant pollutants due to recent reports of their natural production and metabolism. Recent mechanistic studies in human and rats have shown that some OH-PBDEs are more potent than parent compounds (PBDEs) and may contribute substantially to neurodevelopmental disorders by direct neurotoxicity, or indirectly through altered thyroid disruption. However, analytical methodologies for determination of OH-PBDEs are currently limited. In this study a robust liquid chromatography-electrospray tandem triple quadrupole-linear ion trap mass spectrometer (LC-ESI-QqLIT-MS-MS) in negative mode method was developed for the determination of eleven OH-tri- to OH-hexa-PBDEs. Two different columns were tested and compared for chromatographic separation: a C18 BetaBasic and a Purospher STAR RP 18, working at pH 8 and 10, respectively. Mobile phase (acetonitrile:water) was optimized by changing the pH of the aqueous phase and the concentration of the organic modifier (methanol). The MS-MS parameters (declustering potential (DP), collision energy (CE) and cell exit potential (CXP)) were optimized. Selected reaction monitoring (SRM) was used in order to increase sensitivity. Two SRM transitions ([M-H](-)>[Br](-)) were selected for each OH-PBDE, one for quantification and the second one for confirmation. Under the optimized conditions, the instrumental limits of detection were between 0.17 and 0.72injectedpg. The method provided good linearity (r>0.99 for a concentration range of 0.30-100ng/mL), accuracy and precision (%Dev and %RSD≤20% for intra- and inter-assays). Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Comprehensive Characterization of Extractable and Nonextractable Phenolic Compounds by High-Performance Liquid Chromatography-Electrospray Ionization-Quadrupole Time-of-Flight of a Grape/Pomegranate Pomace Dietary Supplement.

    Science.gov (United States)

    Pérez-Ramírez, Iza F; Reynoso-Camacho, Rosalía; Saura-Calixto, Fulgencio; Pérez-Jiménez, Jara

    2018-01-24

    Grape and pomegranate are rich sources of phenolic compounds, and their derived products could be used as ingredients for the development of functional foods and dietary supplements. However, the profile of nonextractable or macromolecular phenolic compounds in these samples has not been evaluated. Here, we show a comprehensive characterization of extractable and nonextractable phenolic compounds of a grape/pomegranate pomace dietary supplement using high-performance liquid chromatography-electrospray ionization-quadrupole time-of-flight (HPLC-ESI-QTOF) and matrix-assisted laser desorption/ionization (MALDI)-TOF techniques. The main extractable phenolic compounds were several anthocyanins (principally malvidin 3-O-glucoside) as well as gallotannins and gallagyl derivatives; some phenolic compounds were reported in grape or pomegranate for the first time. Additionally, there was a high proportion of nonextractable phenolic compounds, including vanillic acid, and dihydroxybenzoic acid. Unidentified polymeric structures were detected by MALDI-TOF MS analysis. This study shows that mixed grape and pomegranate pomaces are a source of different classes of phenolic compounds including a high proportion of nonextractable phenolic compounds.

  2. Use of liquid chromatography/electrospray ionization tandem mass spectrometry to study the degradation pathways of terbuthylazine (TER) by Typha latifolia in constructed wetlands: identification of a new TER metabolite.

    Science.gov (United States)

    Gikas, Evagelos; Papadopoulos, Nikolaos G; Bazoti, Fotini N; Zalidis, Georgios; Tsarbopoulos, Anthony

    2012-01-30

    S-Triazines are used worldwide as herbicides for agricultural and non-agricultural purposes. Although terbuthylazine (TER) is the second most frequently used S-triazine, there is limited information on its metabolism. For this reason, an analytical method based on liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI MS/MS) has been developed aiming at the identification of TER and its five major metabolites (desisopropyl-hydroxy-atrazine, desethyl-hydroxy-terbuthylazine, desisopropyl-atrazine, hydroxy-terbuthylazine and desethyl-terbuthylazine) in constructed wetland water samples. The separation of TER and its major metabolites was performed by reversed-phase high-performance liquid chromatography (HPLC) on a C(8) column using a gradient elution of aqueous acetic acid 1% (solvent A) and acetonitrile (solvent B), followed by MS/MS analysis on a triple quadrupole mass spectrometer. The data-depended analysis (DDA) scan approach has been employed and the main degradation pathways of both hydroxyl and chloro (dealkylated and alkylated) metabolites are elucidated through the tandem mass spectral (MS/MS) interpretation of triazine fragments under CID conditions. In addition, another major metabolite of TER, namely N2-tert-butyl-N4-ethyl-6-methoxy-1,3,5-triazine-2,4-diamine, has been identified. This methodology can be further employed in biodegradation studies of TER, thus assisting the assessment of its environmental impact. Copyright © 2011 John Wiley & Sons, Ltd.

  3. Simultaneous quantification of acetaminophen and five acetaminophen metabolites in human plasma and urine by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry: Method validation and application to a neonatal pharmacokinetic study.

    Science.gov (United States)

    Cook, Sarah F; King, Amber D; van den Anker, John N; Wilkins, Diana G

    2015-12-15

    Drug metabolism plays a key role in acetaminophen (paracetamol)-induced hepatotoxicity, and quantification of acetaminophen metabolites provides critical information about factors influencing susceptibility to acetaminophen-induced hepatotoxicity in clinical and experimental settings. The aims of this study were to develop, validate, and apply high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) methods for simultaneous quantification of acetaminophen, acetaminophen-glucuronide, acetaminophen-sulfate, acetaminophen-glutathione, acetaminophen-cysteine, and acetaminophen-N-acetylcysteine in small volumes of human plasma and urine. In the reported procedures, acetaminophen-d4 and acetaminophen-d3-sulfate were utilized as internal standards (IS). Analytes and IS were recovered from human plasma (10μL) by protein precipitation with acetonitrile. Human urine (10μL) was prepared by fortification with IS followed only by sample dilution. Calibration concentration ranges were tailored to literature values for each analyte in each biological matrix. Prepared samples from plasma and urine were analyzed under the same HPLC-ESI-MS/MS conditions, and chromatographic separation was achieved through use of an Agilent Poroshell 120 EC-C18 column with a 20-min run time per injected sample. The analytes could be accurately and precisely quantified over 2.0-3.5 orders of magnitude. Across both matrices, mean intra- and inter-assay accuracies ranged from 85% to 112%, and intra- and inter-assay imprecision did not exceed 15%. Validation experiments included tests for specificity, recovery and ionization efficiency, inter-individual variability in matrix effects, stock solution stability, and sample stability under a variety of storage and handling conditions (room temperature, freezer, freeze-thaw, and post-preparative). The utility and suitability of the reported procedures were illustrated by analysis of pharmacokinetic samples

  4. [Determination of metformin hydrochloride, melamine and dicyandiamide in metformin hydrochloride preparations by tandem dual solid phase extraction cartridges-high performance liquid chromatography-electrospray ionization multi-stage mass spectrometry].

    Science.gov (United States)

    Zhou, Yanfen; Wang, Fanghuan; Wang, Zelan; Zhan, Haijuan; Liu, Wanyi; Meng, Zhe

    2018-02-08

    A method for the confirmation and quantification of metformin hydrochloride and its relative substances melamine and dicyandiamide using tandem dual solid phase extraction (SPE) cartridges and high performance liquid chromatography-electrospray ionization multi-stage mass spectrometry (HPLC-ESI-MS n ) was developed. The samples were extracted with anhydrous ethanol containing 0.1% (v/v) acetic acid under ultrasound-assisted conditions. The extracts were concentrated and purified using Cleanert PCX and C18 tandem dual solid phase extraction cartridges, and eluted with 5% (v/v) ammonia methanol solution. The separation was performed on a Kromasil-C18 column (100 mm×4.6 mm, 3.5 μm) with gradient elution. The detection was performed in selected ion monitoring (SIM) mode using electrospray ionization multi-stage mass spectrometry. The external standard method was used for quantification. The extraction solvents, types of SPE cartridges and eluents were optimized by comparing the recoveries under different conditions. The results showed that the detector response of each target compound was linear in corresponding mass concentration ranges with the correlation coefficients ( r 2 ) ≥ 0.9992. The limits of detection (LODs) and the limits of quantification (LOQs) of the three analytes were 1.48-13.61 μg/kg and 5.96-45.67 μg/kg, respectively. The recoveries of the three analytes were 65.02%-118.33% spiked at low, medium and high levels. The relative standard deviations (RSDs) were no more than 13.41%. The method is reliable, easy, and has a better purification effect. The method can be applied to the routine analysis of metformin hydrochloride and its relative substances melamine and dicyandiamide in different preparations of metformin hydrochloride.

  5. Sensitive determination of thiols in wine samples by a stable isotope-coded derivatization reagent d0/d4-acridone-10-ethyl-N-maleimide coupled with high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry analysis.

    Science.gov (United States)

    Lv, Zhengxian; You, Jinmao; Lu, Shuaimin; Sun, Weidi; Ji, Zhongyin; Sun, Zhiwei; Song, Cuihua; Chen, Guang; Li, Guoliang; Hu, Na; Zhou, Wu; Suo, Yourui

    2017-03-31

    As the key aroma compounds, varietal thiols are the crucial odorants responsible for the flavor of wines. Quantitative analysis of thiols can provide crucial information for the aroma profiles of different wine styles. In this study, a rapid and sensitive method for the simultaneous determination of six thiols in wine using d 0 /d 4 -acridone-10-ethyl-N-maleimide (d 0 /d 4 -AENM) as stable isotope-coded derivatization reagent (SICD) by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) has been developed. Quantification of thiols was performed by using d 4 -AENM labeled thiols as the internal standards (IS), followed by stable isotope dilution HPLC-ESI-MS/MS analysis. The AENM derivatization combined with multiple reactions monitoring (MRM) not only allowed trace analysis of thiols due to the extremely high sensitivity, but also efficiently corrected the matrix effects during HPLC-MS/MS and the fluctuation in MS/MS signal intensity due to instrument. The obtained internal standard calibration curves for six thiols were linear over the range of 25-10,000pmol/L (R 2 ≥0.9961). Detection limits (LODs) for most of analytes were below 6.3pmol/L. The proposed method was successfully applied for the simultaneous determination of six kinds of thiols in wine samples with precisions ≤3.5% and recoveries ≥78.1%. In conclusion, the developed method is expected to be a promising tool for detection of trace thiols in wine and also in other complex matrix. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Liquid chromatography-electrospray ionization tandem mass spectrometry for on-line characterization, monitoring and isotopic profiling of the main selenium-metabolite in human urine after consumption of Se-rich and Se-enriched food

    International Nuclear Information System (INIS)

    Dumont, Emmie; Ogra, Yasumitsu; Suzuki, Kazuo T.; Vanhaecke, Frank; Cornelis, Rita

    2006-01-01

    The metabolism of selenium (Se) in the human body has yet not completely been unravelled and hence, an efficient method for characterization and on-line monitoring of the main Se-compound in human urine after consumption of Se-rich food was developed. Total Se-concentration in human urine after consumption of several Se-rich products was measured with inductively coupled plasma mass spectrometry (ICP-MS). The highest Se concentration in urine was observed after 4-10 h. The urine samples were brought onto a reversed phase column and the Se was detected by ICP-MS. Parameters for liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) measurements were optimized by using commercially available sugars, because it is known that some of the urinary metabolites contain a sugar moiety. In order to characterize the predominant Se-metabolite, it was necessary to extensively clean-up the sample and preconcentrate the species. The main metabolite was measured on its precursor ion on three different m/z according to three isotopes of Se. Relative peak surfaces matched the relative abundances of the isotopes. The product ions could be measured in a human urine sample in accordance to the product ions of the commercially available sugars. Moreover, the evidence of a selenosugar was demonstrated by the use of the Se-isotopes when measuring the product ions. LC-ESI-MS-MS was proven to be very efficient for the characterization of the main urinary Se-metabolite and can be used for on-line monitoring of the compound in urine samples. The method can be extended for clinical screening after consumption of Se-(en)rich(ed) food by use of the Se-isotopic profile and/or of the typical product ions of (methyl)-N-acetyl-hexosamines

  7. Regiospecific analysis of neutral ether lipids by liquid chromatography/electrospray ionization/single quadrupole mass spectrometry: validation with synthetic compounds

    DEFF Research Database (Denmark)

    Hartvigsen, Karsten; Ravandi, A.; Bukhave, Klaus

    2001-01-01

    A reversed-phase high-performance liquid chromatography (HPLC) method with on-line electrospray ionization/collision-induced dissociation/mass spectrometry (ESI/CID/MS) is presented for the regiospecific analysis of synthetic reference compounds of neutral ether lipids. The reference compounds were...... characterized by chromatographic retention times, full mass spectra, and fragmentation patterns as an aid to clarify the regiospecificity of ether lipids from natural sources. The results clearly show that single quadrupole mass spectroscopic analysis may elucidate the regiospecific structure of neutral ether...... + H - H2O](+), whereas the reverse situation characterized the sn-3 species. Furthermore, corresponding sn-2 and sn-3 species were separated by the chromatographic system. However, loss of water was promoted as fatty acid unsaturation was raised, which may complicate interpretation of the mass spectra...

  8. Determination of pharmaceutical compounds in surface- and ground-water samples by solid-phase extraction and high-performance liquid chromatography-electrospray ionization mass spectrometry

    Science.gov (United States)

    Cahill, J.D.; Furlong, E.T.; Burkhardt, M.R.; Kolpin, D.; Anderson, L.G.

    2004-01-01

    Commonly used prescription and over-the-counter pharmaceuticals are possibly present in surface- and ground-water samples at ambient concentrations less than 1 μg/L. In this report, the performance characteristics of a combined solid-phase extraction isolation and high-performance liquid chromatography–electrospray ionization mass spectrometry (HPLC–ESI-MS) analytical procedure for routine determination of the presence and concentration of human-health pharmaceuticals are described. This method was developed and used in a recent national reconnaissance of pharmaceuticals in USA surface waters. The selection of pharmaceuticals evaluated for this method was based on usage estimates, resulting in a method that contains compounds from diverse chemical classes, which presents challenges and compromises when applied as a single routine analysis. The method performed well for the majority of the 22 pharmaceuticals evaluated, with recoveries greater than 60% for 12 pharmaceuticals. The recoveries of angiotensin-converting enzyme inhibitors, a histamine (H2) receptor antagonist, and antihypoglycemic compound classes were less than 50%, but were retained in the method to provide information describing the potential presence of these compounds in environmental samples and to indicate evidence of possible matrix enhancing effects. Long-term recoveries, evaluated from reagent-water fortifications processed over 2 years, were similar to initial method performance. Method detection limits averaged 0.022 μg/L, sufficient for expected ambient concentrations. Compound-dependent matrix effects on HPLC/ESI-MS analysis, including enhancement and suppression of ionization, were observed as a 20–30% increase in measured concentrations for three compounds and greater than 50% increase for two compounds. Changing internal standard and more frequent ESI source maintenance minimized matrix effects. Application of the method in the national survey demonstrates that several

  9. Determination of phosphatidylethanolamine molecular species in various food matrices by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS2).

    Science.gov (United States)

    Zhou, Li; Zhao, Minjie; Ennahar, Saïd; Bindler, Françoise; Marchioni, Eric

    2012-04-01

    A liquid chromatographic-electrospray ionization-tandem mass spectrometric (LC-ESI-MS(2)) method has been developed for determination of the molecular species of phosphatidylethanolamine (PE) in four food matrices (soy, egg yolk, ox liver, and krill oil). The extraction and purification method consisted of a pressurized liquid extraction procedure for total lipid (TL) extraction, purification of phospholipids (PLs) by adsorption on a silica gel column, and separation of PL classes by semi-preparative normal-phase HPLC. Separation and identification of PE molecular species were performed by reversed-phase HPLC coupled with electrospray ionization tandem mass spectrometry (ESI-MS(2)). Methanol containing 5 mmol L(-1) ammonium formate was used as the mobile phase. A variety of PE molecular species were detected in the four food matrices. (C16:0-C18:2)PE, (C18:2-C18:2)PE, and (C16:0-C18:1)PE were the major PE molecular species in soy. Egg yolk PE contained (C16:0-C18:1)PE, (C18:0-C18:1)PE, (C18:0-C18:2)PE, and (C16:0-C18:2)PE as the major molecular species. Ox liver PE was rich in the species (C18:0-C18:1)PE, (C18:0-C20:4)PE, and (C18:0-C18:2)PE. Finally, krill oil which was particularly rich in (C16:0(alkyl)-C22:6(acyl))plasmanylethanolamine (PakE), (C16:0-C22:6)PE, and (C16:0-C20:5)PE, seemed to be an interesting potential source for supplementation of food with eicosapentaenoic acid and docosahexaenoic acid.

  10. Rapid Screening and Characterization of Acetylcholinesterase Inhibitors from Yinhuang Oral Liquid Using Ultrafiltration-liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry

    Science.gov (United States)

    Zhang, Haomin; Guo, Yinan; Meng, Lingwen; Sun, Hui; Yang, Yinping; Gao, Ying; Sun, Jiaming

    2018-01-01

    Background: At present, approximately 17–25 million people in the world suffer from Alzheimer's disease (AD). The most efficacious and acceptable therapeutic drug clinically are the acetylcholinesterase inhibitors (AChEIs). Yinhuang oral liquid is a Chinese medicine preparation which contains AChEIs according to the literatures. However, no strategy has been presented for rapid screening and identification of AChEIs from Yinhuang oral liquid. Objective: To develop a method for rapid screening and identification of AChEIs from Yinhuang oral liquid using ultrafiltration–liquid chromatography–electrospray ionization tandem mass spectrometry (UF-LC-ESI-MS/MS). Materials and Methods: In this study, UF incubation conditions such as enzyme concentration, incubation time, and incubation temperature were optimized so as to get better screening results. The AChEIs from Yinhuang oral liquid were identified by high-performance liquid chromatography-ESI-MS and the improved Ellman method was used for the AChE inhibitory activity test in vitro. Results: The results showed that Yinhuang oral liquid can inhibit the activity of AChE. We screened and identified seven compounds with potential AChE inhibitory activity from Yinhuang oral liquid, which provided experimental basis for the treatment and prevention of AD. Conclusion: The current technique was used to directly screen the active ingredients with acetylcholinesterase inhibition from complex traditional Chinese medicine, which was simple, rapid, accurate, and suitable for high-throughput screening of AChEI from complex systems. SUMMARY A UF-LC-ESI-MS/MS method for rapid screening and identification of AChEIs from Yinhuang oral liquid was developedSeven compounds were screened and identified with potential AChE inhibitory activity from Yinhuang oral liquidIt provided experimental basis of Yinhuang oral liquid for the treating and preventing AD. Abbreviations used: (AD): Alzheimer's disease; (UF

  11. Determination of benzothiazole and benzotriazole derivates in tire and clothing textile samples by high performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Avagyan, Rozanna; Sadiktsis, Ioannis; Thorsén, Gunnar; Östman, Conny; Westerholm, Roger

    2013-09-13

    A high performance liquid chromatography-tandem mass spectrometry method utilizing electrospray ionization in positive and negative mode has been developed for the separation and detection of benzothiazole and benzotriazole derivates. Ultra-sonication assisted solvent extraction of these compounds has also been developed and the overall method demonstrated on a selected clothing textile and an automobile tire sample. Matrix effects and extraction recoveries, as well as linearity and limits of detection have been evaluated. The calibration curves spanned over more than two orders of magnitude with coefficients of correlation R(2)>0.99 and the limits of detection and the limits of quantification were in the range 1.7-58pg injected and 18-140pg/g, respectively. The extraction recoveries ranged between 69% and 102% and the matrix effects between 75% and 101%. Benzothiazole and benzotriazole derivates were determined in the textile sample and benzothiazole derivatives determined in the tire sample with good analytical performance. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Low-molecular weight protein profiling of genetically modified maize using fast liquid chromatography electrospray ionization and time-of-flight mass spectrometry.

    Science.gov (United States)

    Koc, Anna; Cañuelo, Ana; Garcia-Reyes, Juan F; Molina-Diaz, Antonio; Trojanowicz, Marek

    2012-06-01

    In this work, the use of liquid chromatography coupled to electrospray time-of-flight mass spectrometry (LC-TOFMS) has been evaluated for the profiling of relatively low-molecular weight protein species in both genetically modified (GM) and non-GM maize. The proposed approach consisted of a straightforward sample fractionation with different water and ethanol-based buffer solutions followed by separation and detection of the protein species using liquid chromatography with a small particle size (1.8 μm) C(18) column and electrospray-time-of-flight mass spectrometry detection in the positive ionization mode. The fractionation of maize reference material containing different content of transgenic material (from 0 to 5% GM) led to five different fractions (albumins, globulins, zeins, zein-like glutelins, and glutelins), all of them containing different protein species (from 2 to 52 different species in each fraction). Some relevant differences in the quantity and types of protein species were observed in the different fractions of the reference material (with different GM contents) tested, thus revealing the potential use of the proposed approach for fast protein profiling and to detect tentative GMO markers in maize. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Analysis of hydrolyzable tannins and other phenolic compounds in emblic leafflower (Phyllanthus emblica L.) fruits by high performance liquid chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Yang, Baoru; Kortesniemi, Maaria; Liu, Pengzhan; Karonen, Maarit; Salminen, Juha-Pekka

    2012-09-05

    Phenolic compounds were extracted from dried emblic leafflower (Phyllanthus emblica L.) fruits with methanol and separated by Sephadex LH-20 column chromatography. The raw extracts and fractions were analyzed with HPLC coupled with diode array UV spectroscopy, electrospray ionization mass spectrometry, and tandem mass spectrometry. Mucic acid gallate, mucic acid lactone gallate, monogalloylglucose, gallic acid, digalloylglucose, putranjivain A, galloyl-HHDP-glucose, elaeocarpusin, and chebulagic acid were suggested to be the most abundant compounds in the crude methanol extracts of the fruits. In addition, 144 peaks were detected, of which 67 were tentatively identified mostly as ellagitannins, flavonoids, and simple gallic acid derivatives in the fractions. The results indicated the presence of neochebulagic acid, isomers of neochebuloyl galloylglucose, chebuloyl neochebuloyl galloylglucose, ellagic acid glycosides, quercetin glycosides, and eriodictyol coumaroyl glycosides in the fruits. The study provides a systematic report of the retention data and characteristics of UV, MS, and MS/MS spectra of the phenolic compounds in the fruits of emblic leafflower. The fruits of two varieties (Ping Dan No 1 and Fruity) from Guangxi Province differed from those of wild Tian Chuan emblic leafflower from Fujian Province in the content and profile of phenolic compounds.

  14. Comprehensive analysis of pyrimidine metabolism in 450 children with unspecific neurological symptoms using high-pressure liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Schmidt, C; Hofmann, U; Kohlmüller, D; Mürdter, T; Zanger, U M; Schwab, M; Hoffmann, G F

    2005-01-01

    To evaluate the significance of inborn metabolic disorders of the pyrimidine degradation pathway, 450 children with unspecific neurological symptoms were comprehensively studied; 200 healthy children were recruited as controls. Uracil and thymine as well as their degradation products in urine were determined with an improved method based on reversed-phase HPLC coupled with electrospray ionization tandem mass spectrometry and detection by multiple-reaction monitoring using stable-isotope-labelled reference compounds as internal standards. From the results of the control group we established age-related reference ranges of all pyrimidine degradation products. In the patient group, two children with dihydropyrimidine dehydrogenase (DPYD) deficiency were identified; one of these was homozygous for the exon 14-skipping mutation of the DPYD gene. In addition, two patients with high uracil, dihydrouracil and beta-ureidopropionate were found to have ornithine transcarbamylase deficiency. In the urine of 9 patients, beta-alanine was markedly elevated owing to treatment with vigabatrin, an irreversible inhibitor of GABA transaminase, which interferes with beta-alanine breakdown. Four patients had exclusively high levels of beta-aminoisobutyrate (beta-AIB) due to a low activity of the D-beta-AIB-pyruvate aminotransferase, probably without clinical significance. In conclusion, quantitative investigation of pyrimidine metabolites in children with unexplained neurological symptoms, particularly epileptic seizures with or without psychomotor retardation, can be recommended as a helpful tool for diagnosis in clinical practice. Sensitive methods and age-related reference ranges enable the detection of partial enzyme deficiencies.

  15. Automated Gain Control and Internal Calibration With External Ion Accumulation Capillary liquid chromatography-electrospray ionization-fourier transform ion cyclotron resonance.

    Energy Technology Data Exchange (ETDEWEB)

    Belov, Mikhail E.(VISITORS); Zhang, Rui (BATTELLE (PACIFIC NW LAB)); Strittmatter, Eric F.(BATTELLE (PACIFIC NW LAB)); Prior, David C.(BATTELLE (PACIFIC NW LAB)); Tang, Keqi (BATTELLE (PACIFIC NW LAB)); Smith, Richard D.(BATTELLE (PACIFIC NW LAB))

    2003-08-15

    When combined with capillary LC separations, Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (ESI-FTICR MS) has increasingly been applied for advanced characterization of proteolytic digests. Incorporation of external (to the ICR cell) ion accumulation multipoles with FTICR for ion pre selection and accumulation has enhanced the dynamic range, sensitivity and duty cycle of measurements. However, the highly variable ion production rate from an LC separation can result in overfilling of the external trap, resulting in m/z discrimination and fragmentation of peptide ions. An excessive space charge trapped in the ICR cell causes significant shifts in the detected ion cyclotron frequencies, reducing the achievable mass measurement accuracy (MMA) for protein identification. To eliminate m/z discrimination in the external ion trap, further increase the duty cycle and improve MMA, we developed a capability for data-dependent adjustment of ion accumulation times in the course of an LC separation, referred to as Automated Gain Control (AGC), in combination with low kinetic energy gated ion trapping and internal calibration using a dual-channel electrodynamic ion funnel. The system was initially evaluated in the analysis of a 0.5 mg/mL tryptic digest of bovine serum albumin. The implementation of LC/ESI/AGC/FTICR with internal calibration gave rise to a {approx} 10-fold increase in the number of identified tryptic peptides within mass measurement accuracy of 2 ppm as compared to that detected during the conventional LC/FTICR run with a fixed ion accumulation time and external calibration.

  16. Benzylic rearrangement stable isotope labeling for quantitation of guanidino and ureido compounds in thyroid tissues by liquid chromatography-electrospray ionization mass spectrometry

    International Nuclear Information System (INIS)

    Fan, Ruo-Jing; Guan, Qing; Zhang, Fang; Leng, Jia-Peng; Sun, Tuan-Qi; Guo, Yin-Long

    2016-01-01

    Benzylic rearrangement stable isotope labeling (BRSIL) was explored to quantify the guanidino and ureido compounds (GCs and UCs). This method employed a common reagent, benzil, to label the guanidino and ureido groups through nucleophilic attacking then benzylic migrating. The use of BRSIL was investigated in the analysis of five GCs (creatine, L-arginine, homoarginine, 4-guanidinobutyric acid, and methylguanidine) and two UCs (urea and citrulline). The labeling was found simple and specific. The introduction of bi-phenyl group and the generation of nitrogen heterocyclic ring in the benzil-d0/d5 labeled GCs and UCs improved the retention behaviors in liquid chromatography (LC) and increased the sensitivity of electrospray ionization mass spectrometry (ESI MS) detection. The fragment ion pairs of m/z 182/187 and m/z 210/215 from the benzil-d0/d5 tags facilitated the discovery of potential GCs and UCs candidates residing in biological matrices. The use of BRSIL combined with LC-ESI MS was applied for simultaneously quantitation of GCs and UCs in thyroid tissues. It was demonstrated that nine GCs and UCs were detected, six of which were further quantified based on corresponding standards. It was concluded that five GCs and UCs (L-arginine, homoarginine, 4-guanidinobutyric acid, methylguanidine, and citrulline) were statistically significantly different (p < 0.05) between the para-carcinoma and carcinoma thyroid tissue samples. - Highlights: • A common reagent, benzil-d0/d5 was employed to label the GCs and UCs through BRSIL. • The benzil-d0/d5 labeling improved the retention behavior in RPLC and increased the sensitivity by ESI MS detection. • BRSIL coupled with LC-ESI MS was applied to the qualitation and quantitation of GCs and UCs in thyroid tissues.

  17. Analysis of trichloroethylene-induced global DNA hypomethylation in hepatic L-02 cells by liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Hang; Hong, Wen-Xu; Ye, Jinbo; Yang, Xifei; Ren, Xiaohu; Huang, Aibo; Yang, Linqing; Zhou, Li; Huang, Haiyan; Wu, Desheng; Huang, Xinfeng; Zhuang, Zhixiong; Liu, Jianjun

    2014-04-04

    Trichloroethylene (TCE), a major occupational and environmental pollutant, has been recently associated with aberrant epigenetic changes in experimental animals and cultured cells. TCE is known to cause severe hepatotoxicity; however, the association between epigenetic alterations and TCE-induced hepatotoxicity are not yet well explored. DNA methylation, catalyzed by enzymes known as DNA methyltransferases (DNMT), is a major epigenetic modification that plays a critical role in regulating many cellular processes. In this study, we analyzed the TCE-induced effect on global DNA methylation and DNMT enzymatic activity in human hepatic L-02 cells. A sensitive and quantitative method combined with liquid chromatography and electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) was validated and utilized for assessing the altered DNA methylation in TCE-induced L-02 cells. Quantification was accomplished in multiple reaction monitoring (MRM) mode by monitoring a transition pair of m/z 242.1 (molecular ion)/126.3 (fragment ion) for 5-mdC and m/z 268.1/152.3 for dG. The correlation coefficient of calibration curves between 5-mdC and dG was higher than 0.9990. The intra-day and inter-day relative standard derivation values (RSD) were on the range of 0.53-7.09% and 0.40-2.83%, respectively. We found that TCE exposure was able to significantly decrease the DNA methylation and inhibit DNMT activity in L-02 cells. Our results not only reveal the association between TCE exposure and epigenetic alterations, but also provide an alternative mass spectrometry-based method for rapid and accurate assessment of chemical-induced altered DNA methylation in mammal cells. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Benzylic rearrangement stable isotope labeling for quantitation of guanidino and ureido compounds in thyroid tissues by liquid chromatography-electrospray ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Ruo-Jing [State Key Laboratory of Organmetallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032 (China); Guan, Qing [Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center, Shanghai, 200032 (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, 200032 (China); Zhang, Fang, E-mail: fzhang@sioc.ac.cn [State Key Laboratory of Organmetallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032 (China); Leng, Jia-Peng [State Key Laboratory of Organmetallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032 (China); Sun, Tuan-Qi, E-mail: tuanqisun@163.com [Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center, Shanghai, 200032 (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, 200032 (China); Guo, Yin-Long, E-mail: ylguo@sioc.ac.cn [State Key Laboratory of Organmetallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032 (China)

    2016-02-18

    Benzylic rearrangement stable isotope labeling (BRSIL) was explored to quantify the guanidino and ureido compounds (GCs and UCs). This method employed a common reagent, benzil, to label the guanidino and ureido groups through nucleophilic attacking then benzylic migrating. The use of BRSIL was investigated in the analysis of five GCs (creatine, L-arginine, homoarginine, 4-guanidinobutyric acid, and methylguanidine) and two UCs (urea and citrulline). The labeling was found simple and specific. The introduction of bi-phenyl group and the generation of nitrogen heterocyclic ring in the benzil-d0/d5 labeled GCs and UCs improved the retention behaviors in liquid chromatography (LC) and increased the sensitivity of electrospray ionization mass spectrometry (ESI MS) detection. The fragment ion pairs of m/z 182/187 and m/z 210/215 from the benzil-d0/d5 tags facilitated the discovery of potential GCs and UCs candidates residing in biological matrices. The use of BRSIL combined with LC-ESI MS was applied for simultaneously quantitation of GCs and UCs in thyroid tissues. It was demonstrated that nine GCs and UCs were detected, six of which were further quantified based on corresponding standards. It was concluded that five GCs and UCs (L-arginine, homoarginine, 4-guanidinobutyric acid, methylguanidine, and citrulline) were statistically significantly different (p < 0.05) between the para-carcinoma and carcinoma thyroid tissue samples. - Highlights: • A common reagent, benzil-d0/d5 was employed to label the GCs and UCs through BRSIL. • The benzil-d0/d5 labeling improved the retention behavior in RPLC and increased the sensitivity by ESI MS detection. • BRSIL coupled with LC-ESI MS was applied to the qualitation and quantitation of GCs and UCs in thyroid tissues.

  19. Using precursor ion scan of 184 with liquid chromatography-electrospray ionization-tandem mass spectrometry for concentration normalization in cellular lipidomic studies.

    Science.gov (United States)

    Chao, Hsi-Chun; Chen, Guan-Yuan; Hsu, Lih-Ching; Liao, Hsiao-Wei; Yang, Sin-Yu; Wang, San-Yuan; Li, Yu-Liang; Tang, Sung-Chun; Tseng, Yufeng Jane; Kuo, Ching-Hua

    2017-06-08

    Cellular lipidomic studies have been favored approaches in many biomedical research areas. To provide fair comparisons of the studied cells, it is essential to perform normalization of the determined concentration before lipidomic analysis. This study proposed a cellular lipidomic normalization method by measuring the phosphatidylcholine (PC) and sphingomyelin (SM) contents in cell extracts. To provide efficient analysis of PC and SM in cell extracts, flow injection analysis-electrospray ionization-tandem mass spectrometry (FIA-ESI-MS/MS) with a precursor ion scan (PIS) of m/z 184 was used, and the parameters affecting the performance of the method were optimized. Good linearity could be observed between the cell extract dilution factor and the reciprocal of the total ion chromatogram (TIC) area in the PIS of m/z 184 within the dilution range of 1- to 16-fold (R 2  = 0.998). The calibration curve could be used for concentration adjustment of the unknown concentration of a cell extract. The intraday and intermediate precisions were below 10%. The accuracy ranged from 93.0% to 105.6%. The performance of the new normalization method was evaluated using different numbers of HCT-116 cells. Sphingosine, ceramide (d18:1/18:0), SM (d18:1/18:0) and PC (16:1/18:0) were selected as the representative test lipid species, and the results showed that the peak areas of each lipid species obtained from different cell numbers were within a 20% variation after normalization. Finally, the PIS of 184 normalization method was applied to study ischemia-induced neuron injury using oxygen and glucose deprivation (OGD) on primary neuronal cultured cells. Our results showed that the PIS of 184 normalization method is an efficient and effective approach for concentration normalization in cellular lipidomic studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Identification and quantification of glucosamine in rabbit cartilage and correlation with plasma levels by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Pastorini, Elisabetta; Vecchiotti, Stefania; Colliva, Carolina; Persiani, Stefano; Rotini, Roberto; Roatti, Giulia; Zaccarelli, Lorenzo; Rovati, Lucio Claudio; Roda, Aldo

    2011-01-01

    Graphical abstract: Highlights: → Optimization of an HPLC-ESI-MS/MS method for glucosamine in rabbit cartilage. → Application of the method to an in-vivo study. → Glucosamine presence in cartilage in physiological condition. → Significant increase of cartilage glucosamine concentration after dosing. → Good correlation between cartilage glucosamine levels and plasma concentrations. - Abstract: A new HPLC-ESI-MS/MS method for the determination of glucosamine (2-amino-2-deoxy-D-glucose) in rabbit cartilage was developed and optimized. Glucosamine was extracted from cartilage by cryogenic grinding followed by protein precipitation with trichloroacetic acid. The HPLC separation was achieved with a polymer-based amino column using a mobile phase composed of 10 mM ammonium acetate (pH 7.5)-acetonitrile (20:80%, v/v) at 0.3 mL min -1 flow rate. D-[1- 13 C]Glucosamine was used as internal standard. Selective detection was performed by tandem mass spectrometry with electrospray source, operating in positive ionization mode and in multiple reaction monitoring acquisition (m/z 180 → 72 and 181 → 73 for glucosamine and internal standard, respectively). Limit of quantification was 0.045 ng injected, corresponding to 0.25 μg g -1 in cartilage. Linearity was obtained up to 20 μg g -1 (R 2 > 0.991). Precision values (%R.S.D.) were -1 (n = 6). Glucosamine was present in cartilage in physiological condition before the treatment. After dosing, mean concentration of cartilage glucosamine significantly increased from 461 to 1040 ng g -1 . Cartilage glucosamine levels resulted to be well correlated with plasma concentrations, which therefore are useful to predict the target cartilage concentration and its pharmacological activity.

  1. Seasonal variations in the profile of main phospholipids in Mytilus galloprovincialis mussels: A study by hydrophilic interaction liquid chromatography-electrospray ionization Fourier transform mass spectrometry.

    Science.gov (United States)

    Facchini, Laura; Losito, Ilario; Cataldi, Tommaso R I; Palmisano, Francesco

    2018-01-01

    A systematic characterization of phosphatidylcholines and phosphatidylethanolamines in mussels of sp Mytilus galloprovincialis was performed by high-efficiency hydrophilic interaction liquid chromatography combined with electrospray ionization and Fourier transform mass spectrometry (FTMS), based on a quadrupole-Orbitrap hybrid spectrometer. The FTMS/MS experiments under high collisional energy dissociation conditions, complemented by low-energy collisionally induced dissociation MS n (n = 2,3) experiments, performed in a linear ion trap mass spectrometer, were exploited for structural elucidation purposes. The described approach led to an unprecedented characterization of the mussel phospholipidome, with 185 phosphatidylcholines and 131 phosphatidylethanolamines species recognized, distributed among diacylic, plasmanylic, and plasmenylic forms. This was the starting point for the evaluation of the effects of season (in particular, of sea temperature) on the profile of those phospholipids. To this aim, a set of mussel samples retrieved from commercial sources in different periods of the year was considered. Principal component analysis revealed a clear separation between samples collected in periods characterized by cold, intermediate, or warm sea temperatures, respectively. In particular, an enrichment in phospholipids containing unsaturated side chains was observed in mussels collected from cold seawaters (winter-early spring), thus confirming the general model previously elaborated to explain the adaptation of marine invertebrates, including some bivalve molluscs, to low temperatures. On the other hand, relevant levels of plasma(e)nylic and acylic phospholipids bearing either saturated or non-methylene-interrupted side chains were found in mussels collected in warm seawaters (typical of summer and early autumn, at Italian latitudes). This finding opened interesting perspectives towards the development of strategies able to prevent global warming-related mussel

  2. Power of Ultra Performance Liquid Chromatography/Electrospray Ionization-MS Reconstructed Ion Chromatograms in the Characterization of Small Differences in Polymer Microstructure.

    Science.gov (United States)

    Epping, Ruben; Panne, Ulrich; Falkenhagen, Jana

    2018-03-06

    From simple homopolymers to functionalized, 3-dimensional structured copolymers, the complexity of polymeric materials has become more and more sophisticated. With new applications, for instance, in the semiconductor or pharmaceutical industry, the requirements for the characterization have risen with the complexity of the used polymers. For each additional distribution, an additional dimension in analysis is needed. Small, often isomeric heterogeneities in topology or microstructure can usually not be simply separated chromatographically or distinguished by any common detector but affect the properties of materials significantly. For a drug delivery system, for example, the degree of branching and branching distribution is crucial for the formation of micelles. Instead of a complicated, time-consuming, and/or expensive 2D-chromatography or ion mobility spectrometry (IMS) method, that also has its limitations, in this work, a simple approach using size exclusion chromatography (SEC) coupled with electrospray ionization (ESI) mass spectrometry is proposed. The online coupling allows the analysis of reconstructed ion chromatograms (RICs) of each degree of polymerization. While a complete separation often cannot be achieved, the derived retention times and peak widths lead to information on the existence and dispersity of heterogeneities. Although some microstructural heterogeneities like short chain branching can for large polymers be characterized with methods such as light scattering, for oligomers where the heterogeneities just start to form and their influence is at the maximum, they are inaccessible with these methods. It is also shown that with a proper calibration even quantitative information can be obtained. This method is suitable to detect small differences in, e.g., branching, 3D-structure, monomer sequence, or tacticity and could potentially be used in routine analysis to quickly determine deviations.

  3. Determination of gardenia yellow colorants in soft drink, pastry, instant noodles with ultrasound-assisted extraction by high performance liquid chromatography-electrospray ionization tandem mass spectrum.

    Science.gov (United States)

    Zhou, Wei-E; Zhang, Yuan; Li, Yang; Ling, Yun; Li, Hong-Na; Li, Shao-Hui; Jiang, Shou-Jun; Ren, Zhi-Qin; Huang, Zhi-Qiang; Zhang, Feng

    2016-05-13

    A novel, rapid and simple analytical method was developed for the quantitative determination of crocin, crocetin and geniposide in soft drink, pastry and instant noodles. The solid samples were relatively homogenized into powders and fragments. The gardenia yellow colorants were successively extracted with methanol using ultrasound-assisted extraction. The analytes were quantitatively measured in the extracts by liquid chromatography coupled with electrospray ionization tandem mass spectrometry. High correlation coefficients (r(2)>0.995) of crocin, crocetin and geniposide were obtained within their linear ranges respectively (50-1000ng/mL, 50-1000ng/mL, 15-240ng/mL) by external standard method. The limits of detection (LODs) were 0.02μg/g for crocin, 0.01μg/g for crocetin and 0.002μg/g for geniposide. And the limits of quantitation (LOQs) were in the ranges of 0.05-0.45μg/g for crocin, and in the ranges of 0.042-0.32μg/g for crocetin, and in the ranges of 0.02-0.15μg/g for geniposide in soft drink, pastry and instant noodles samples. The average recoveries of crocin, crocetin and geniposide ranged from 81.3% to 117.6% in soft drink, pastry and instant noodles. The intra- and inter-day precisions were respectively in the range of 1.3-4.8% and 1.7-11.8% in soft drink, pastry and instant noodle. The developed methods were successfully validated and applied to the soft drink, pastry, and instant noodles collected from the located market in Beijing from China. Crocin, crocetin and geniposide were detected in the collected samples. The average concentrations ranged from 0.84 to 4.20mg/g for crocin, and from 0.62 to 3.11mg/g for crocetin, and from 0.18 to 0.79mg/g for gardenia in various food samples. The method can provide evidences for government to determine gardenia yellow pigments and geniposide in food. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Identification of intact high molecular weight glutenin subunits from the wheat proteome using combined liquid chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Lagrain, Bert; Brunnbauer, Markus; Rombouts, Ine; Koehler, Peter

    2013-01-01

    The present paper describes a method for the identification of intact high molecular weight glutenin subunits (HMW-GS), the quality determining proteins from the wheat storage proteome. The method includes isolation of HMW-GS from wheat flour, further separation of HMW-GS by reversed-phase high-performance liquid chromatography (RP-HPLC), and their subsequent molecular identification with electrospray ionization mass spectrometry using a quadrupole-time-of-flight mass analyzer. For HMW-GS isolation, wheat proteins were reduced and extracted from flour with 50% 1-propanol containing 1% dithiothreitol. HMW-GS were then selectively precipitated from the protein mixture by adjusting the 1-propanol concentration to 60%. The composition of the precipitated proteins was first evaluated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis with Coomassie staining and RP-HPLC with ultraviolet detection. Besides HMW-GS (≥65%), the isolated proteins mainly contained ω5-gliadins. Secondly, the isolated protein fraction was analyzed by liquid chromatography-mass spectrometry. Optimal chromatographic separation of HMW-GS from the other proteins in the isolated fraction was obtained when the mobile phase contained 0.1% trifluoroacetic acid as ion-pairing agent. Individual HMW-GS were then identified by determining their molecular masses from the high-resolution mass spectra and comparing these with theoretical masses calculated from amino acid sequences. Using formic acid instead of trifluoroacetic acid in the mobile phase increased protein peak intensities in the base peak mass chromatogram. This allowed the detection of even traces of other wheat proteins than HMW-GS in the isolated fraction, but the chromatographic separation was inferior with a major overlap between the elution ranges of HMW-GS and ω-gliadins. Overall, the described method allows a rapid assessment of wheat quality through the direct determination of the HMW-GS composition and offers a basis for

  5. Identification of intact high molecular weight glutenin subunits from the wheat proteome using combined liquid chromatography-electrospray ionization mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Bert Lagrain

    Full Text Available The present paper describes a method for the identification of intact high molecular weight glutenin subunits (HMW-GS, the quality determining proteins from the wheat storage proteome. The method includes isolation of HMW-GS from wheat flour, further separation of HMW-GS by reversed-phase high-performance liquid chromatography (RP-HPLC, and their subsequent molecular identification with electrospray ionization mass spectrometry using a quadrupole-time-of-flight mass analyzer. For HMW-GS isolation, wheat proteins were reduced and extracted from flour with 50% 1-propanol containing 1% dithiothreitol. HMW-GS were then selectively precipitated from the protein mixture by adjusting the 1-propanol concentration to 60%. The composition of the precipitated proteins was first evaluated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis with Coomassie staining and RP-HPLC with ultraviolet detection. Besides HMW-GS (≥65%, the isolated proteins mainly contained ω5-gliadins. Secondly, the isolated protein fraction was analyzed by liquid chromatography-mass spectrometry. Optimal chromatographic separation of HMW-GS from the other proteins in the isolated fraction was obtained when the mobile phase contained 0.1% trifluoroacetic acid as ion-pairing agent. Individual HMW-GS were then identified by determining their molecular masses from the high-resolution mass spectra and comparing these with theoretical masses calculated from amino acid sequences. Using formic acid instead of trifluoroacetic acid in the mobile phase increased protein peak intensities in the base peak mass chromatogram. This allowed the detection of even traces of other wheat proteins than HMW-GS in the isolated fraction, but the chromatographic separation was inferior with a major overlap between the elution ranges of HMW-GS and ω-gliadins. Overall, the described method allows a rapid assessment of wheat quality through the direct determination of the HMW-GS composition and

  6. Determination of crenolanib in human serum and cerebrospinal fluid by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS).

    Science.gov (United States)

    Roberts, Michael S; Turner, David C; Owens, Thandranese S; Ramachandran, Abhijit; Wetmore, Cynthia; Throm, Stacy L; Stewart, Clinton F

    2013-06-15

    A LC-ESI-MS/MS method for the determination of crenolanib (CP-868,596) in human serum was developed and validated employing d4-CP-868,596 as an internal standard (ISTD). In addition to human serum, the method was also partially validated for crenolanib determination in human cerebrospinal fluid (CSF) samples. Sample aliquots (50μl of serum or CSF) were prepared for analysis using liquid-liquid extraction (LLE) with tert-butyl methyl ether. Chromatography was performed using a phenomenex Gemini C18 column (3μm, 100mm×4.6mm I.D.) in a column heater set at 50°C and an isocratic mobile phase (methanol/water/formic acid at a volume ratio of 25/25/0.15, v/v/v). The flow rate was 0.45mL/min, and the retention time for both analyte and ISTD was less than 3.5min. Samples were analyzed with an API-5500 LC-MS/MS system (ESI) in positive ionization mode coupled to a Shimadzu HPLC system. The ion transitions monitored were m/z 444.4→373.1 and m/z 448.2→374.2 for crenolanib and ISTD, respectively. The method was linear over the range of 5-1000ng/mL for serum and 0.5-1000ng/mL for CSF. For human serum, both intra-day and inter-day precision were <4%, while intra-day and inter-day accuracy were within 8% of nominal values. Recovery was greater than 50% for both the analyte and ISTD. For CSF samples, both intra-day and inter-day precision were <9% except at the lower limit of quantification (LLOQ) which was <17%. The intra-day and inter-day accuracy were within 11% of the nominal CSF concentrations. After validation, this method was successfully applied to the analysis of serial pharmacokinetic samples obtained from a child treated with oral crenolanib. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Role of neuropeptide Y in the regulation of gonadotropin releasing hormone system in the forebrain of Clarias batrachus (Linn.): immunocytochemistry and high performance liquid chromatography-electrospray ionization-mass spectrometric analysis.

    Science.gov (United States)

    Gaikwad, A; Biju, K C; Muthal, P L; Saha, S; Subhedar, N

    2005-01-01

    Although the importance of neuropeptide Y (NPY) in the regulation of gonadotropin releasing hormone (GnRH) and reproduction has been highlighted in recent years, the neuroanatomical substrate within which these substances might interact has not been fully elucidated. Present work was undertaken with a view to define the anatomical-physiological correlates underlying the role exercised by NPY in the regulation of GnRH in the forebrain of the teleost Clarias batrachus. Application of double immunocytochemistry revealed close associations as well as colocalizations of the two peptides in the olfactory receptor neurons (ORNs), olfactory nerve fibers and their terminals in the glomeruli, ganglion cells of nervus terminalis, medial olfactory tract, fibers in the area ventralis telencephali/pars supracommissuralis and cells as well as fibers in the pituitary. NPY containing axons were found to terminate in the vicinity of GnRH cells in the pituitary with light as well as electron microscopy. Double immunoelectron microscopy demonstrated gold particles for NPY and GnRH colocalized on the membrane and in dense core of the secretory granules in the cells distributed in all components of the pituitary gland. To assess the physiological implication of these observations, NPY was injected via the intracranial route and the response of GnRH immunoreactive system was evaluated by relative quantitative morphometry as well as high performance liquid chromatography (HPLC) analysis. Two hours following NPY (20 ng/g body weight) administration, a dramatic increase was observed in the GnRH immunoreactivity in the ORNs, in the fibers of the olfactory bulb (163%) and medial olfactory tract (351%). High performance liquid chromatography-electrospray ionization-mass spectrometric analysis confirmed the immunocytochemical data. Significant rise in the salmon GnRH (sGnRH)-like peptide content was observed in the olfactory organ (194.23%), olfactory bulb (146.64%), telencephalon+preoptic area

  8. Optimization of the Extraction of Anthocyanins from the Fruit Skin of Rhodomyrtus tomentosa (Ait. Hassk and Identification of Anthocyanins in the Extract Using High-Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometry (HPLC-ESI-MS

    Directory of Open Access Journals (Sweden)

    Yuan-Ming Sun

    2012-05-01

    Full Text Available Anthocyanins are naturally occurring polyphenols that impart bright color to fruits, vegetables and plants. In this study, the extraction of anthocyanins from freeze-dried fruit skin of downy rose-myrtle (Rhodomyrtus tomentosa (Ait. Hassk var. Gangren was optimized using response surface methodology (RSM. Using 60% ethanol containing 0.1% (v/v hydrochloric acid as extraction solvent, the optimal conditions for maximum yields of anthocyanin (4.358 ± 0.045 mg/g were 15.7:1 (v/w liquid to solid ratio, 64.38 °C with a 116.88 min extraction time. The results showed good fits with the proposed model for the anthocyanin extraction (R2 = 0.9944. Furthermore, the results of high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS analysis of the anthocyanins extracted from the fruit skin of downy rose-myrtle revealed the presence of five anthocyanin components, which were tentatively identified as delphinidin-3-glucoside, cyanidin-3-glucoside, peonidin-3-glucoside, petunidin-3-glucoside and malvidin-3-glucoside.

  9. Determination of drug residues in urine of dogs receiving anti-cancer chemotherapy by liquid chromatography-electrospray ionization- tandem mass spectrometry: is there an environmental or occupational risk?

    Science.gov (United States)

    Hamscher, Gerd; Mohring, Siegrun A I; Knobloch, Anna; Eberle, Nina; Nau, Heinz; Nolte, Ingo; Simon, Daniela

    2010-04-01

    Cytotoxic drugs, previously used only in human medicine, are increasingly utilized for cancer treatment in veterinary practice. We developed and validated a liquid chromatography (LC)-electrospray ionization-tandem mass spectrometry (MS-MS) method to determine vincristine, vinblastine, cyclophosphamide, and doxorubicin in canine urine. Sample pretreatment consisted of liquid-liquid extraction, and LC separation was carried out on an RP C(18) column employing a 0.5% formic acid/methanol gradient system. The analytes were detected in positive ion mode using the MS-MS scan mode. The mean recoveries in six different urine samples were between 64.2% and 86.9%. Limits of quantitation were 0.5 microg/L for vincristine and vinblastine, 1 microg/L for cyclophosphamide, and 5 microg/L for doxorubicin; limits of detection were approximately 0.25 microg/L for vincristine, vinblastine, and cyclophosphamide and 0.5 microg/L for doxorubicin. It could be demonstrated that all investigated drugs are found in urine of dogs undergoing chemotherapy. In samples from day 1 after chemotherapy, as much as 63 microg/L vincristine, 111 microg/L vinblastine, and 762 microg/L doxorubicin could be detected. Cyclophosphamide showed only minor concentrations on day 1, but up to 2583 microg/L could be found directly after chemotherapy. These initial data show that there might be a potential contamination risk when administering cytotoxics in veterinary medicine.

  10. Biotransformation of the high-molecular weight polycyclic aromatic hydrocarbon (PAH) benzo[k]fluoranthene by Sphingobium sp. strain KK22 and identification of new products of non-alternant PAH biodegradation by liquid chromatography electrospray ionization tandem mass spectrometry

    Science.gov (United States)

    Maeda, Allyn H; Nishi, Shinro; Hatada, Yuji; Ozeki, Yasuhiro; Kanaly, Robert A

    2014-01-01

    A pathway for the biotransformation of the environmental pollutant and high-molecular weight polycyclic aromatic hydrocarbon (PAH) benzo[k]fluoranthene by a soil bacterium was constructed through analyses of results from liquid chromatography negative electrospray ionization tandem mass spectrometry (LC/ESI(–)-MS/MS). Exposure of Sphingobium sp. strain KK22 to benzo[k]fluoranthene resulted in transformation to four-, three-and two-aromatic ring products. The structurally similar four-and three-ring non-alternant PAHs fluoranthene and acenaphthylene were also biotransformed by strain KK22, and LC/ESI(–)-MS/MS analyses of these products confirmed the lower biotransformation pathway proposed for benzo[k]fluoranthene. In all, seven products from benzo[k]fluoranthene and seven products from fluoranthene were revealed and included previously unreported products from both PAHs. Benzo[k]fluoranthene biotransformation proceeded through ortho-cleavage of 8,9-dihydroxy-benzo[k]fluoranthene to 8-carboxyfluoranthenyl-9-propenic acid and 9-hydroxy-fluoranthene-8-carboxylic acid, and was followed by meta-cleavage to produce 3-(2-formylacenaphthylen-1-yl)-2-hydroxy-prop-2-enoic acid. The fluoranthene pathway converged with the benzo[k]fluoranthene pathway through detection of the three-ring product, 2-formylacenaphthylene-1-carboxylic acid. Production of key downstream metabolites, 1,8-naphthalic anhydride and 1-naphthoic acid from benzo[k]fluoranthene, fluoranthene and acenaphthylene biotransformations provided evidence for a common pathway by strain KK22 for all three PAHs through acenaphthoquinone. Quantitative analysis of benzo[k]fluoranthene biotransformation by strain KK22 confirmed biodegradation. This is the first pathway proposed for the biotransformation of benzo[k]fluoranthene by a bacterium. PMID:24325265

  11. Biotransformation of the high-molecular weight polycyclic aromatic hydrocarbon (PAH) benzo[k]fluoranthene by Sphingobium sp. strain KK22 and identification of new products of non-alternant PAH biodegradation by liquid chromatography electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Maeda, Allyn H; Nishi, Shinro; Hatada, Yuji; Ozeki, Yasuhiro; Kanaly, Robert A

    2014-03-01

    A pathway for the biotransformation of the environmental pollutant and high-molecular weight polycyclic aromatic hydrocarbon (PAH) benzo[k]fluoranthene by a soil bacterium was constructed through analyses of results from liquid chromatography negative electrospray ionization tandem mass spectrometry (LC/ESI(-)-MS/MS). Exposure of Sphingobium sp. strain KK22 to benzo[k]fluoranthene resulted in transformation to four-, three- and two-aromatic ring products. The structurally similar four- and three-ring non-alternant PAHs fluoranthene and acenaphthylene were also biotransformed by strain KK22, and LC/ESI(-)-MS/MS analyses of these products confirmed the lower biotransformation pathway proposed for benzo[k]fluoranthene. In all, seven products from benzo[k]fluoranthene and seven products from fluoranthene were revealed and included previously unreported products from both PAHs. Benzo[k]fluoranthene biotransformation proceeded through ortho-cleavage of 8,9-dihydroxy-benzo[k]fluoranthene to 8-carboxyfluoranthenyl-9-propenic acid and 9-hydroxy-fluoranthene-8-carboxylic acid, and was followed by meta-cleavage to produce 3-(2-formylacenaphthylen-1-yl)-2-hydroxy-prop-2-enoic acid. The fluoranthene pathway converged with the benzo[k]fluoranthene pathway through detection of the three-ring product, 2-formylacenaphthylene-1-carboxylic acid. Production of key downstream metabolites, 1,8-naphthalic anhydride and 1-naphthoic acid from benzo[k]fluoranthene, fluoranthene and acenaphthylene biotransformations provided evidence for a common pathway by strain KK22 for all three PAHs through acenaphthoquinone. Quantitative analysis of benzo[k]fluoranthene biotransformation by strain KK22 confirmed biodegradation. This is the first pathway proposed for the biotransformation of benzo[k]fluoranthene by a bacterium. © 2013 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  12. Liquid Chromatography Electrospray Ionization Tandem Mass Spectrometric (LC/ESI-MS/MS) Study for the Identification and Characterization of In Vivo Metabolites of Cisplatin in Rat Kidney Cancer Tissues: Online Hydrogen/Deuterium (H/D) Exchange Study.

    Science.gov (United States)

    Bandu, Raju; Ahn, Hyun Soo; Lee, Joon Won; Kim, Yong Woo; Choi, Seon Hee; Kim, Hak Jin; Kim, Kwang Pyo

    2015-01-01

    In vivo rat kidney tissue metabolites of an anticancer drug, cisplatin (cis-diamminedichloroplatinum [II]) (CP) which is used for the treatment of testicular, ovarian, bladder, cervical, esophageal, small cell lung, head and neck cancers, have been identified and characterized by using liquid chromatography positive ion electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) in combination with on line hydrogen/deuterium exchange (HDX) experiments. To identify in vivo metabolites, kidney tissues were collected after intravenous administration of CP to adult male Sprague-Dawley rats (n = 3 per group). The tissue samples were homogenized and extracted using newly optimized metabolite extraction procedure which involves liquid extraction with phosphate buffer containing ethyl acetate and protein precipitation with mixed solvents of methanol-water-chloroform followed by solid-phase clean-up procedure on Oasis HLB 3cc cartridges and then subjected to LC/ESI-HRMS analysis. A total of thirty one unknown in vivo metabolites have been identified and the structures of metabolites were elucidated using LC-MS/MS experiments combined with accurate mass measurements. Online HDX experiments have been used to further support the structural characterization of metabolites. The results showed that CP undergoes a series of ligand exchange biotransformation reactions with water and other nucleophiles like thio groups of methionine, cysteine, acetylcysteine, glutathione and thioether. This is the first research approach focused on the structure elucidation of biotransformation products of CP in rats, and the identification of metabolites provides essential information for further pharmacological and clinical studies of CP, and may also be useful to develop various effective new anticancer agents.

  13. Validation of a Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry Method for Determination of All-Trans Retinoic Acid in Human Plasma and Its Application to a Bioequivalence Study

    Directory of Open Access Journals (Sweden)

    Jing-Bo Peng

    2014-01-01

    Full Text Available A sensitive, reliable and specific LC-MS-MS method was developed and validated for the identification and quantitation of all-trans retinoic acid (ATRA in human plasma. Acitretin was used as the internal standard (IS. After liquid-liquid extraction of 500 μL plasma with methyl tert-butyl ether (MTBE, ATRA and the IS were chromatographed on a HyPURITY C18 column (150 mm × 2.1 mm, 5 μm with the column temperature set at 40 °C. The mobile phase was consisted of 40% phase A (MTBE–methanol–acetic acid, 50:50:0.5, v/v and 60% phase B (water–methanol–acetic acid, 50:50:0.5, v/v with a flow rate of 0.3 mL/min. The API 4000 triple quadrupole mass spectrometer was operated in multiple reaction monitoring (MRM mode via the positive electrospray ionization interface using the transition m/z 301.4 → 123.1 for ATRA and m/z 326.9 → 177.1 for IS, respectively. The calibration curve was linear over the range of 0.45–217.00 ng/mL (r ≥ 0.999 with a lower limit of quantitation (LLOQ of 0.45 ng/mL. The intra- and inter-day precisions values were below 8% relative standard deviation and the accuracy was from 98.98% to 106.19% in terms of relative error. The validated method was successfully applied in a bioequivalence study of ATRA in Chinese healthy volunteers.

  14. Application of liquid chromatography/electrospray ionization ion trap tandem mass spectrometry for the evaluation of global nucleic acids: methylation in garden cress under exposure to CuO nanoparticles.

    Science.gov (United States)

    Alcazar Magana, Armando; Wrobel, Kazimierz; Corrales Escobosa, Alma Rosa; Wrobel, Katarzyna

    2016-01-15

    A full understanding of the biological impact of nanomaterials demands analytical procedures suitable for the detection/quantification of epigenetic changes that occur in the exposed organisms. Here, the effect of CuO nanoparticles (NPs) on global methylation of nucleic acids in Lepidium sativum was evaluated by liquid chromatography/ion trap mass spectrometry. Enhanced selectivity toward cytosine-containing nucleosides was achieved by using their proton-bound dimers formed in positive electrospray ionization (ESI(+)) as precursor ions for multiple reaction monitoring (MRM) quantification based on one or two ion transitions. Plants were exposed to CuO NPs (0-1000 mg L(-1)); nucleic acid extracts were washed with bathocuproine disulfate; nucleosides were separated on a Luna C18 column coupled via ESI(+) to an AmaZon SL mass spectrometer (Bruker Daltonics). Cytidine, 2´-deoxycytidine, 5-methylcytidine, 5-methyl-2´-deoxycytidine and 5-hydroxymethyl-2´-deoxycytidine were quantified by MRM based on MS(3) ([2M+H](+)/[M+H](+)/[M+H-132](+) or [M+H-116](+)) and MS(2) ([2M+H](+)/[M+H](+) ). Bathocuproine disulfate, added as Cu(I) complexing agent, allowed for elimination of [2M+Cu](+) adducts from the mass spectra. Poorer instrumental detection limits were obtained for MS(3) (20-120 fmol) as compared to MS(2) (9.0-41 fmol); however, two ion transitions helped to eliminate matrix effects in plant extracts. The procedure was tested by analyzing salmon sperm DNA (Sigma) and applied for the evaluation of DNA and RNA methylation in plants; in the absence of NPs, 13.03% and 0.92% methylated cytosines were found in DNA and RNA, respectively; for NPs concentration >50 mg L(-1), DNA hypomethylation was observed with respect to unexposed plants. RNA methylation did not present significant changes upon plant exposure; 5-hydroxymethyl-2´-deoxycytidine was not detected in any sample. The MRM quantification proposed here of cytosine-containing nucleosides using their proton-bound homo

  15. Analysis of the differentially expressed low molecular weight peptides in human serum via an N-terminal isotope labeling technique combining nano-liquid chromatography/matrix-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Leng, Jiapeng; Zhu, Dong; Wu, Duojiao; Zhu, Tongyu; Zhao, Ningwei; Guo, Yinlong

    2012-11-15

    Peptidomics analysis of human serum is challenging due to the low abundance of serum peptides and interference from the complex matrix. This study analyzed the differentially expressed (DE) low molecular weight peptides in human serum integrating a DMPITC-based N-terminal isotope labeling technique with nano-liquid chromatography and matrix-assisted laser desorption/ionization mass spectrometry (nano-LC/MALDI-MS). The workflow introduced a [d(6)]-4,6-dimethoxypyrimidine-2-isothiocyanate (DMPITC)-labeled mixture of aliquots from test samples as the internal standard. The spiked [d(0)]-DMPITC-labeled samples were separated by nano-LC then spotted on the MALDI target. Both quantitative and qualitative studies for serum peptides were achieved based on the isotope-labeled peaks. The DMPITC labeling technique combined with nano-LC/MALDI-MS not only minimized the errors in peptide quantitation, but also allowed convenient recognition of the labeled peptides due to the 6 Da mass difference. The data showed that the entire research procedure as well as the subsequent data analysis method were effective, reproducible, and sensitive for the analysis of DE serum peptides. This study successfully established a research model for DE serum peptides using DMPITC-based N-terminal isotope labeling and nano-LC/MALDI-MS. Application of the DMPITC-based N-terminal labeling technique is expected to provide a promising tool for the investigation of peptides in vivo, especially for the analysis of DE peptides under different biological conditions. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Analysis of oak tannins by liquid chromatography-electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Mämmelä, P; Savolainen, H; Lindroos, L; Kangas, J; Vartiainen, T

    2000-09-01

    Extractable tannins were analysed by liquid chromatography-electrospray ionisation mass spectrometry in two oak species, North American white oak (Quercus alba) and European red oak (Quercus robur). They mainly included various glucose gallic and ellagic acid esters. The structures were partially determined, and they included grandinin/roburin E, castalagin/vescalagin, gallic acid, valoneic acid bilactone, monogalloyl glucose, digalloyl glucose, trigalloyl glucose, ellagic acid rhamnose, quercitrin and ellagic acid.

  17. Instrument platforms for nano liquid chromatography.

    Science.gov (United States)

    Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav

    2015-11-20

    The history of liquid chromatography started more than a century ago and miniaturization and automation are two leading trends in this field. Nanocolumn liquid chromatography (nano LC) and largely synonymous capillary liquid chromatography (capillary LC) are the most recent results of this process where miniaturization of column dimensions and sorbent particle size play crucial role. Very interesting results achieved in the research of extremely miniaturized LC columns at the end of the last century lacked distinctive raison d'être and only advances in mass spectrometry brought a real breakthrough. Configuration of nano LC-electrospray ionization mass spectrometry (LC-ESI-MS) has become a basic tool in bioanalytical chemistry, especially in proteomics. This review discusses and summarizes past and current trends in the realization of nano liquid chromatography (nano LC) platforms. Special attention is given to the mobile phase delivery under nanoflow rates (isocratic, gradient) and sample injection to the nanocolumn. Available detection techniques applied in nano LC separations are also briefly discussed. We followed up the key themes from the original scientific reports over gradual improvements up to the contemporary commercial solutions. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Detection of over 100 selenium metabolites in selenized yeast by liquid chromatography electrospray time-of-flight mass spectrometry.

    Science.gov (United States)

    Gilbert-López, Bienvenida; Dernovics, Mihaly; Moreno-González, David; Molina-Díaz, Antonio; García-Reyes, Juan F

    2017-08-15

    The characterization of the selenometabolome of Selenized(Se)-yeast, that is the fraction of water soluble low-molecular weight Se-metabolites produced in Se-yeast is of paramount interest to expand the knowledge on the composition of this food supplement. In this work, we have applied liquid chromatography electrospray time-of-flight mass spectrometry (LC-TOFMS) to search for Se-species from the low molecular weight range fraction of the selenized yeast used for food supplements. Prior to LC-TOFMS, sample treatment consisted of ultrasound assisted water extraction followed by size exclusion fractionation assisted with off-line inductively coupled plasma mass spectrometry detection of isotope 82 Se. The fraction corresponding to low-molecular weight species was subjected to LC-TOFMS using electrospray ionization in the positive ion mode. The detection of the suspected selenized species has been based on the information obtained from accurate mass measurements of both the protonated molecules and fragments from in-source CID fragmentation; along with the characteristic isotope pattern exhibited by the presence of Se. The approach enables the detection of 103 selenized species, most of them not previously reported, in the range from ca. 300-650Da. Besides the detection of selenium species, related sulphur derivate metabolites were detected based on the accurate mass shift due to the substitution of sulphur and selenium. Copyright © 2017. Published by Elsevier B.V.

  19. Enantiomeric quantification of (S)-(+)-methamphetamine in urine by an immunoaffinity column and liquid chromatography-electrospray-mass spectrometry

    International Nuclear Information System (INIS)

    Lua, Ahai C.; Sutono, Yenny; Chou, T.-Y.

    2006-01-01

    A method using an immunoaffinity column (IAC) and liquid chromatography-electrospray ionization mass spectrometry (LC/MS) for on-line detecting the presence of MA in the effluent was developed for the quantitative and enantiomeric determination of (S)-(+)-methamphetamine (D-MA) in urine. The IAC was made in our laboratory and utilized in the LC/MS to simultaneously extract and separate enantiomers of MA from urine samples. An aqueous ammonium acetate buffer was used as the mobile phase. Urine samples were spiked with racemic deuterated methamphetamine (MA-d 14 ) as internal standard (IS), filtered through a membrane, and injected into the LC/MS without any further pre-treatment. Protonated molecular ion of MA and MA-d 14 (m/z 150 and 164) were isolated and further fragmented, the respective product ions, m/z 119 and 130, were collected for quantitative determination. This is an improvement of our previous method (A.C. Lua, Tsong-Yung Chou, J. Chromatogr. A 967 (2002) 191). In the previous method, MA was separated with HPLC, the efflux was fractionated and each fraction was either determined with an immunoassay or GC/MS. Monitoring of MA in the efflux is tedious and time consuming. Urine samples spiked with different concentrations of D-MA were measured by this method. A linear relationship exists in the 150-1050 ng/mL range, and the detection limit (defined as signal-to-noise ratio 3) of D-MA was determined to be 18 ng/mL. The linearity of the method for D-MA can be described by the equation (Y = 1.415 x 10 -3 X + 0.034, correlation coefficient: r 2 = 0.999). Within run, accuracy and precision (n = 6, relative error: -7.2 to +4.0% and relative standard deviation: 3.8-9.3%) of the method are fairly good

  20. Enantiomeric quantification of (S)-(+)-methamphetamine in urine by an immunoaffinity column and liquid chromatography-electrospray-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lua, Ahai C. [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China); Sutono, Yenny [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China); Chou, T.-Y. [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China)]. E-mail: cty@mail.tcu.edu.tw

    2006-08-18

    A method using an immunoaffinity column (IAC) and liquid chromatography-electrospray ionization mass spectrometry (LC/MS) for on-line detecting the presence of MA in the effluent was developed for the quantitative and enantiomeric determination of (S)-(+)-methamphetamine (D-MA) in urine. The IAC was made in our laboratory and utilized in the LC/MS to simultaneously extract and separate enantiomers of MA from urine samples. An aqueous ammonium acetate buffer was used as the mobile phase. Urine samples were spiked with racemic deuterated methamphetamine (MA-d{sub 14}) as internal standard (IS), filtered through a membrane, and injected into the LC/MS without any further pre-treatment. Protonated molecular ion of MA and MA-d{sub 14} (m/z 150 and 164) were isolated and further fragmented, the respective product ions, m/z 119 and 130, were collected for quantitative determination. This is an improvement of our previous method (A.C. Lua, Tsong-Yung Chou, J. Chromatogr. A 967 (2002) 191). In the previous method, MA was separated with HPLC, the efflux was fractionated and each fraction was either determined with an immunoassay or GC/MS. Monitoring of MA in the efflux is tedious and time consuming. Urine samples spiked with different concentrations of D-MA were measured by this method. A linear relationship exists in the 150-1050 ng/mL range, and the detection limit (defined as signal-to-noise ratio 3) of D-MA was determined to be 18 ng/mL. The linearity of the method for D-MA can be described by the equation (Y = 1.415 x 10{sup -3} X + 0.034, correlation coefficient: r {sup 2} = 0.999). Within run, accuracy and precision (n = 6, relative error: -7.2 to +4.0% and relative standard deviation: 3.8-9.3%) of the method are fairly good.

  1. Instrument platforms for nano liquid chromatography

    Czech Academy of Sciences Publication Activity Database

    Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav

    2015-01-01

    Roč. 1421, NOV (2015), s. 2-17 ISSN 0021-9673 R&D Projects: GA MV VG20112015021 Institutional support: RVO:68081715 Keywords : nano liquid chromatography * splitless gradient generation * nano LC platforms Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.926, year: 2015 http://hdl.handle.net/11104/0250900

  2. Determination of pyrrolizidine alkaloids in comfrey by liquid chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Liu, Feng; Wan, Sow Yin; Jiang, Zhangjian; Li, Sam Fong Yau; Ong, Eng Shi; Osorio, Jhon Carlos Castaño

    2009-12-15

    Symphytum officinale L. (comfrey) is a medicinal plant commonly used in decoctions and aliments. Besides therapeutic bioactive compounds present in the herb, it is found to contain hepatotoxic pyrrolizidine alkaloids (PAs), such as lycopsamine and others. In the present study, PAs such as lycopsamine, echimidine and lasiocarpine were determined using electrospray liquid chromatography-mass spectrometry (LC-MS) with the method precision (relative standard deviation, RSD) comfrey followed by the comparison with heating under reflux with the RSD ranging from 2.49% to 19.32%. Our results showed a higher extraction efficiency for heating under reflux compared with PHWE. It was proposed that the lower extraction efficiency for PHWE was attributable to dissolved nitrogen from air which caused the reduction in the solubility of lycopsamine in the compressed hot solvent. In this study, quantitative analysis of PAs in comfrey was demonstrated. In addition, it was found that the use of subcritical water for extractions depended on the physical properties of the dissolved solutes and their tendency to degrade under the chosen extraction conditions.

  3. The analysis of aqueous mixtures using liquid chromatography-electrospray mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Steven [Iowa State Univ., Ames, IA (United States)

    1999-02-12

    The focus of this dissertation is the use of chromatographic methods coupled with electrospray mass spectrometry (ES-MS) for the determination of both organic and inorganic compounds in aqueous solutions. The combination of liquid chromatography (LC) methods and ES-MS offers one of the foremost methods for determining compounds in complex aqueous solutions. In this work, LC-ES-MS methods are devised using ion exclusion chromatography, reversed phase chromatography, and ion exchange chromatography, as well as capillary electrophoresis (CE). For an aqueous sample, these LC-ES-MS and CE-ES-MS techniques require no sample preparation or analyte derivatization, which makes it possible to observe a wide variety of analytes as they exist in solution. The majority of this work focuses on the use of LC-ES-MS for the determination of unknown products and intermediates formed during electrochemical incineration (ECI), an experimental waste remediation process. This report contains a general introduction to the project and the general conclusions. Four chapters have been removed for separate processing. Titles are: Chapter 2: Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry; Chapter 3: Electrochemical incineration of benzoquinone in aqueous media using a quaternary metal oxide electrode in the absence of a soluble supporting electrolyte; Chapter 4: The determination of electrochemical incineration products of 4-chlorophenol by liquid chromatography-electrospray mass spectrometry; and Chapter 5: Determination of small carboxylic acids by capillary electrophoresis with electrospray mass spectrometry.

  4. Identification and Quantification of Glucosinolates in Kimchi by Liquid Chromatography-Electrospray Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ho Jin Kim

    2017-01-01

    Full Text Available A novel and simple method for detecting five glucosinolates (glucoalyssin, gluconapin, glucobrassicanapin, glucobrassicin, and 4-methoxyglucobrassicin in kimchi was developed using liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS. The chromatographic peaks of the five glucosinolates were successfully identified by comparing their retention times, mass spectra. The mobile phase was composed of A (acetonitrile and B (water. As for glucosinolate, the relative quantities were found through sinigrin, and five different compounds that have not been previously discovered in kimchi were observed. Monitoring was carried out on the glucosinolate in 20 kimchis distributed in markets, and this study examined the various quality and quantity compositions of the five components. The glucoalyssin content ranged from 0.00 to 7.07 μmol/g of day weight (DW, with an average content of 0.86 μmol/g of DW, whereas the gluconapin content ranged from 0.00 to 5.85 μmol/g of DW, with an average of 1.17 μmol/g of DW. The content of glucobrassicanapin varied between 0.00 and 11.87 μmol/g of DW (average = 3.03 μmol/g of DW, whereas that of glucobrassicin varied between 0.00 and 0.42 μmol/g of DW (average = 0.06 μmol/g of DW. The 4-methoxyglucobrassicin content ranged from 0.12 to 9.36 μmol/g of DW (average = 3.52 μmol/g of DW. A comparison of the contents revealed that, in most cases, the content of 4-methoxyglucobrassicin was the highest.

  5. POLAR ORGANIC CHEMICAL INTEGRATIVE SAMPLING AND LIQUID CHROMATOGRAPHY-ELECTROSPRAY/ION-TRAP MASS SPECTROMETRY FOR ASSESSING SELECTED PRESCRIPTION AND ILLICIT DRUGS IN TREATED SEWAGE EFFLUENTS

    Science.gov (United States)

    The purpose of the research presented in this paper is two-fold: (1) to demonstrate the 4 coupling of two state-of-the-art techniques: a time-weighted polar organic integrative sampler (POCIS) and micro-liquid chromatography-electrospray/ion trap mass spectrometry (u-LC-6 ES/ITMS...

  6. Proteomic profiling of human pleural effusion using two-dimensional nano liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Tyan, Yu-Chang; Wu, Hsin-Yi; Lai, Wu-Wei; Su, Wu-Chou; Liao, Pao-Chi

    2005-01-01

    Pleural effusion, an accumulation of pleural fluid, contains proteins originated from plasma filtrate and, especially when tissues are damaged, parenchyma interstitial spaces of lungs and/or other organs. This study details protein profiles in human pleural effusion from 43 lung adenocarcinoma patients by a two-dimensional nano-high performance liquid chromatography electrospray ionization tandem mass spectrometry (2D nano-HPLC-ESI-MS/MS) system. The experimental results revealed the identification of 1415 unique proteins from human pleural effusion. Among these 124 proteins identified with higher confidence levels, some proteins have not been reported in plasma and may represent proteins specifically present in pleural effusion. These proteins are valuable for mass identification of differentially expressed proteins involved in proteomics database and screening biomarker to further study in human lung adenocarcinoma. The significance of the use of proteomics analysis of human pleural fluid for the search of new lung cancer marker proteins, and for their simultaneous display and analysis in patients suffering from lung disorders has been examined.

  7. Determination of chlorpyrifos and its metabolites in cells and culture media by liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Yang, Xiangkun; Wu, Xian; Brown, Kyle A; Le, Thao; Stice, Steven L; Bartlett, Michael G

    2017-09-15

    A sensitive method to simultaneously quantitate chlorpyrifos, chlorpyrifos oxon and the detoxified product 3,5,6-trichloro-2-pyridinol (TCP) was developed using either liquid-liquid extraction for culture media samples, or protein precipitation for cell samples. Multiple reaction monitoring in positive ion mode was applied for the detection of chlorpyrifos and chlorpyrifos oxon, and selected ion recording in negative mode was applied to detect TCP. The method provided linear ranges from 5 to 500, 0.2-20 and 20-2000ng/mL for media samples and from 0.5-50, 0.02-2 and 2-200ng/million cells for CPF, CPO and TCP, respectively. The method was validated using selectivity, linearity, precision, accuracy, recovery, stability and dilution tests. All relative standard deviations (RSDs) and relative errors (REs) for QC samples were within 15% (except for LLOQ, within 20%). This method has been successfully applied to study the neurotoxicity and metabolism of chlorpyrifos in a human neuronal model. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometric Analysis of 2-Alkylcyclobutanones in Irradiated Chicken by Precolumn Derivatization with Hydroxylamine

    NARCIS (Netherlands)

    Ye, Yuran; Liu, Hanxia; Horvatovich, Peter; Chan, Wan

    2013-01-01

    Food irradiation is a common preservation method that is used in many countries. The ability to identify irradiated food is important for assuring compliance with regulatory policies, such as food labeling requirements, and for informed consumer choice. There is thus a significant demand for

  9. Determination of mazindol in human oral fluid by high performance liquid chromatography-electrospray ionization mass spectrometry.

    Science.gov (United States)

    de Oliveira, Marcella Herbstrith; Carlos, Graciela; Bergold, Ana Maria; Pechansky, Flavio; Limberger, Renata Pereira; Fröehlich, Pedro Eduardo

    2014-08-01

    Brazil is one of the countries most affected by abuse of stimulant medications by professional drivers, especially fenproporex, amfepramone and mazindol. Even though their sale is banned, they can be found in illegal markets, such as those located on the country's borders. The use of oral fluid to monitor drug levels has many advantages over plasma and urine because it is noninvasive, easier to collect and more difficult to adulterate. The aim of this study was to develop and validate a sensitive and specific method to quantify mazindol in human oral fluid by liquid chromatography-mass spectrometry (LC-MS). The LC system consisted of an LC-MS system operated in selected ion monitoring mode. The mobile phase was composed of water at pH 4.0, acetonitrile and methanol (60:15:25 v/v/v) at a flow rate of 1.0 mL/min and propranolol was used as internal standard. Total running time was 10 min. The lower limit of quantification was 0.2 ng/mL and the method exhibited good linearity within the 0.2-20 ng/mL range (r = 0.9987). A rapid, specific, sensitive, linear, precise and accurate method was developed for determination of mazindol in human oral fluid according to European Medicines Agency guidelines, and is suitable for monitoring mazindol levels in oral fluid of professional drivers. Copyright © 2014 John Wiley & Sons, Ltd.

  10. A framework to estimate concentrations of potentially unknown substances by semi-quantification in liquid chromatography electrospray ionization mass spectrometry

    DEFF Research Database (Denmark)

    Pieke, Eelco Nicolaas; Granby, Kit; Trier, Xenia

    2017-01-01

    Risk assessment of exposure to chemicals from food and other sources rely on quantitative information of the occurrence of these chemicals. As screening analysis is increasingly used, a strategy to semi-quantify unknown or untargeted analytes is required. A proof of concept strategy to semi-quant...

  11. Quantitation of 5-Methyltetrahydrofolate in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    Science.gov (United States)

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of cerebrospinal fluid (CSF) 5-methyltetrahydrofolate (5-MTHF) as a clinical diagnostic test. 5-MTHF is the main biologically active form of folic acid and is involved in regulation of homocysteine and DNA synthesis. Measurement of 5-MTHF in CSF provides diagnostic information regarding diseases affecting folate metabolism within the central nervous system, in particular inborn errors of folate metabolism. Determination of 5-MTHF in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). 5-MTHF in CSF is determined by a 1:2 dilution with internal standard (5-MTHF-(13)C5) and injected directly onto the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve (25-400 nM) and has an analytical measurement range of 3-1000 nM.

  12. Profiling ABA metabolites in Nicotiana tabacum L. leaves by ultra-performance liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Turecková, Veronika; Novák, Ondrej; Strnad, Miroslav

    2009-11-15

    We have developed a simple method for extracting and purifying (+)-abscisic acid (ABA) and eight ABA metabolites--phaseic acid (PA), dihydrophaseic acid (DPA), neophaseic acid (neoPA), ABA-glucose ester (ABAGE), 7'-hydroxy-ABA (7'-OH-ABA), 9'-hydroxy-ABA (9'-OH-ABA), ABAaldehyde, and ABAalcohol--before analysis by a novel technique for these substances, ultra-performance liquid chromatography-electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS/MS). The procedure includes addition of deuterium-labelled standards, extraction with methanol-water-acetic acid (10:89:1, v/v), simple purification by Oasis((R)) HLB cartridges, rapid chromatographic separation by UPLC, and sensitive, accurate quantification by MS/MS in multiple reaction monitoring modes. The detection limits of the technique ranged between 0.1 and 1 pmol for ABAGE and ABA acids in negative ion mode, and 0.01-0.50 pmol for ABAGE, ABAaldehyde, ABAalcohol and the methylated acids in positive ion mode. The fast liquid chromatographic separation and analysis of ABA and its eight measured derivatives by UPLC-ESI-MS/MS provide rapid, accurate and robust quantification of most of the substances, and the low detection limits allow small amounts of tissue (1-5mg) to be used in quantitative analysis. To demonstrate the potential of the technique, we isolated ABA and its metabolites from control and water-stressed tobacco leaf tissues then analysed them by UPLC-ESI-MS/MS. Only ABA, PA, DPA, neoPA, and ABAGE were detected in the samples. PA was the most abundant analyte (ca. 1000 pmol/g f.w.) in both the control and water-stressed tissues, followed by ABAGE and DPA, which were both present at levels ca. 5-fold lower. ABA levels were at least 100-fold lower than PA concentrations, but they increased following the water stress treatment, while ABAGE, PA, and DPA levels decreased. Overall, the technique offers substantial improvements over previously described methods, enabling the detailed, direct study of

  13. Nano-liquid chromatography applied to enantiomers separation.

    Science.gov (United States)

    Fanali, Salvatore

    2017-02-24

    This paper presents the state of the art concerning the separation of chiral compounds by means of nano-liquid chromatography (nano-LC). The enantiomers' separation and determination are a subject of fundamental importance in various application fields such as pharmaceutical industry, biomedicine, food, agrochemical etc. Nano-LC is a miniaturized chromatographic technique offering some advantages over conventional ones such as low consumption of mobile phase, sample volume and amount of chiral stationary phase, reduced costs etc. This is reported in the first part of the paper illustrating the features of the nano-LC. In addition, chiral resolution methods are briefly illustrated. Some chiral selectors, used in high-performance liquid chromatography have also been applied in nano-LC including cyclodextrins, glycopeptide antibiotics, modified polysaccharides etc. This is discussed in the second part of the review. Finally some examples of the applications available in literature are reported. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Nanoscale Affinity Chip Interface for Coupling Inhibition SPR Immunosensor Screening with Nano-LC TOF MS

    NARCIS (Netherlands)

    Marchesini, G.R.; Buijs, J.; Haasnoot, W.; Hooijerink, H.; Jansson, O.; Nielen, M.W.F.

    2008-01-01

    The on-line nanoscale coupling of a surface plasmon resonance (SPR)-based inhibition biosensor immunoassay (iBIA) for the screening of low molecular weight molecules with nano-liquid-chromatography electrospray ionization time-of-flight mass spectrometry (nano-LC ESI TOF MS) for identification is

  15. A simple and fast method for the inspection of preservatives in cheeses and cream by liquid chromatography- electrospray tandem mass spectrometry.

    Science.gov (United States)

    Molognoni, Luciano; de Sá Ploêncio, Leandro Antunes; Valese, Andressa Camargo; De Dea Lindner, Juliano; Daguer, Heitor

    2016-01-15

    In this work, a simplified extraction and short time of analysis method for the simultaneous determination of natamycin, nisin and sorbic acid in cheeses and cream by reverse phase liquid chromatography-electrospray-tandem mass spectrometry was developed. Full validation was performed according to the Commission Decision 2002/657/EC criteria and method applicability was checked on several samples, aiming to inspect their compliance with regulatory limits. The method was linear in the concentration ranges of 0-10mg kg(-1) (natamycin), 0-25mg kg(-1) (nisin) and 0 20mg kg(-1) (sorbic acid). Samples of the three most consumed types of cheese (fresh, pasta filata and ripened) in Brazil and cream (ultra high temperature and pasteurized, 20-30% fat content) were assessed. A surprising rate of non-compliance was observed, especially among ripened grated cheeses, since 80% of samples were above the maximum limit for sorbic acid with an average concentration of 2766.3±10.8mg kg(-1). Moreover, a major non-compliance for the cream samples was observed. The proposed method can be applied as an efficient tool for the inspection of preservatives in cheeses and cream. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. A liquid chromatography/electrospray ionisation tandem mass spectrometry method for the simultaneous quantification of salicylic, jasmonic and abscisic acids in Coffea arabica leaves.

    Science.gov (United States)

    de Sá, Marta; Ferreira, João P; Queiroz, Vagner T; Vilas-Boas, Luís; Silva, Maria C; Almeida, Maria H; Guerra-Guimarães, Leonor; Bronze, Maria R

    2014-02-01

    Plants have developed an efficient system of recognition that induces a complex network of signalling molecules such as salicylic acid (SA), jasmonic acid (JA) and abscisic acid (ABA) in case of a pathogenic infection. The use of specific and sensitive methods is mandatory for the analysis of compounds in these complex samples. In this study a liquid chromatography/electrospray ionisation tandem mass spectrometry method was developed and validated for the simultaneous quantification of SA, JA and ABA in Coffea arabica (L.) leaves in order to understand the role of these phytohormones in the signalling network involved in the coffee defence response against Hemileia vastatrix. The results showed that the method was specific, linear (r ≥ 0.99) in the range 0.125-1.00 µg mL⁻¹ for JA and ABA and 0.125-5.00 µg mL⁻¹ for SA, and precise (relative standard deviation ≤11%), and the limit of detection (0.010 µg g⁻¹ fresh weight) was adequate for quantifying these phytohormones in this type of matrix. In comparison with healthy leaves, those infected with H. vastatrix (resistance reaction) displayed an increase in SA level 24 h after inoculation, suggesting the involvement of an SA-dependent pathway in coffee resistance. © 2013 Society of Chemical Industry.

  17. Study of ion suppression for phenolic compounds in medicinal plant extracts using liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Faccin, H; Viana, C; do Nascimento, P C; Bohrer, D; de Carvalho, L M

    2016-01-04

    A systematic study on the various sources of ion suppression in UHPLC-MS-MS analysis was carried out for 24 phenolic antioxidants in 6 different extracts of medicinal plants from Amazonia. The contributions of matrix effects, mobile-phase additives, analyte co-elution and electric charge competition during ionization to the global ion suppression were evaluated. Herein, the influence of mobile-phase additives on the ionization efficiency was found to be very pronounced, where ion suppression of approximately 90% and ion enhancement effects greater than 400% could be observed. The negative effect caused by the wrong choice of internal standard (IS) on quantitative studies was also evaluated and discussed from the perspective of ion suppression. This work also shows the importance of performing studies with this approach even for very similar matrices, such as varieties of medicinal plants from the same species, because different effects were observed for the same analyte. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Quantitation of iothalamate in urine and plasma using liquid chromatography electrospray tandem mass spectrometry (HPLC-ESI-MS/MS).

    Science.gov (United States)

    Molinaro, Ross J; Ritchie, James C

    2010-01-01

    The following chapter describes a method to measure iothalamate in plasma and urine samples using high performance liquid chromatography combined with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Methanol and water are spiked with the internal standard (IS) iohexol. Iothalamate is isolated from plasma after IS spiked methanol extraction and from urine by IS spiked water addition and quick-spin filtration. The plasma extractions are dried under a stream of nitrogen. The residue is reconstituted in ammonium acetate-formic acid-water. The reconstituted plasma and filtered urine are injected into the HPLC-ESI-MS/MS. Iothalamate and iohexol show similar retention times in plasma and urine. Quantification of iothalamate in the samples is made by multiple reaction monitoring using the hydrogen adduct mass transitions, from a five-point calibration curve.

  19. Simultaneous quantitative analysis of dextromethorphan, dextrorphan and chlorphenamine in human plasma by liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Ding, Ying; Huang, Kai; Chen, Lan; Yang, Jie; Xu, Wen-Yan; Xu, Xue-Jiao; Duan, Ru; Zhang, Jing; He, Qing

    2014-03-01

    A sensitive and accurate HPLC-MS/MS method was developed for the simultaneous determination of dextromethorphan, dextrorphan and chlorphenamine in human plasma. Three analytes were extracted from plasma by liquid-liquid extraction using ethyl acetate and separated on a Kromasil 60-5CN column (3 µm, 2.1 × 150 mm) with mobile phase of acetonitrile-water (containing 0.1% formic acid; 50:50, v/v) at a flow rate of 0.2 mL/min. Quantification was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The calibration curve was linear over the range of 0.01-5 ng/mL for dextromethorphan, 0.02-5 ng/mL for dextrorphan and 0.025-20 ng/mL for chlorphenamine. The lower limits of quantification for dextromethorphan, dextrorphan and chlorphenamine were 0.01, 0.02 and 0.025 ng/mL, respectively. The intra- and inter-day precisions were within 11% and accuracies were in the range of 92.9-102.5%. All analytes were proved to be stable during sample storage, preparation and analytic procedures. This method was first applied to the pharmacokinetic study in healthy Chinese volunteers after a single oral dose of the formulation containing dextromethorphan hydrobromide (18 mg) and chlorpheniramine malaeate (8 mg). Copyright © 2013 John Wiley & Sons, Ltd.

  20. Quantification of γ-Aminobutyric Acid in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    Science.gov (United States)

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of γ-aminobutyric acid (GABA), a major inhibitory neurotransmitter in human cerebrospinal fluid (CSF) as a clinical diagnostic test. Determination of GABA in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Analysis of free and total GABA requires two individual sample preparations and mass spectrometry analyses. Free GABA in CSF is determined by a 1:2 dilution with internal standard (GABA-D2) and injected directly onto the HPLC-ESI-MS/MS system. Determination of total GABA in CSF requires additional sample preparation in order to hydrolyze all the bound GABA in the sample to the free form. This requires hydrolyzing the sample by boiling in acidic conditions (hydrochloric acid) for 4 h. The sample is then further diluted 1:10 with a 90 % acetonitrile/0.1 % formic acid solution and injected into the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve and is linear from 6 nM to 1000 nM and 0.63 μM to 80 μM for free and total GABA, respectively.

  1. Investigation of pyrrolizidine alkaloids including their respective N-oxides in selected food products available in Hong Kong by liquid chromatography electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Chung, Stephen W C; Lam, Aaron C H

    2017-07-01

    This study determined the levels of pyrrolizidine alkaloids (PAs), including their respective N-oxides, in foodstuffs available in Hong Kong by liquid chromatography-electrospray ionisation tandem mass spectrometry. A total of 234 samples (48 food items) were collected randomly from a local market and analysed. About 50% of samples were found to contain detectable amount of PAs. Amongst the 48 food items, PAs were not detected in 11 food items, including barley flour, beef, cattle liver, pork, pig liver, chicken meat, chicken liver, milk, non-fermented tea, Melissa tea and linden tea. For those found to contain detectable PAs, the summed PA content ranged up to 11,000 µg kg -1 . The highest sum of PA content among the 37 food items calculated with lower bound was cumin seed, then followed by oregano, tarragon and herbs de Provence with ranges of 2.5-11,000, 1.5-5100, 8.0-3300 and 18-1300 µg kg -1 respectively. Among the samples, the highest sum of PA content was detected in a cumin seed sample (11,000 µg kg -1 ), followed by an oregano (5100 µg kg -1 ), a tarragon (3300 µg kg -1 ) and a herbs de Provence (1300 µg kg -1 ). In general, the results of this study agreed well with other published results in peer-reviewed journals, except that the total PAs in honey and specific tea infusion in this study were comparatively lower.

  2. Characterization of steroidal saponins from Dioscorea villosa and D Cayennensis using ultrahigh performance liquid chromatography/electrospray ionization quadruple time-of-flight mass spectrometry

    Science.gov (United States)

    Steroidal saponins were reported to be the major physiologically active constituents in yams. The structural characteristics of steroidal saponins in methanolic extracts from dried rhizomes of two Dioscorea species (D. villosa L. and D. cayenensis Lam.) and dietary supplements have analyzed using U...

  3. Liquid chromatography-electrospray ionization mass spectrometry analysis of limonoids and flavanois in seeds of grapefruits, other citrus species, and dietary supplements

    Science.gov (United States)

    A selective ultra-high performance liquid chromatography-didode array detector-quadrapole time of flight-mass spectrometry (UHPLC-DAD-QToF-MS) method has been developed to screen grapefruit seeds, and other citrus seed samples for limonoid aglycones, limonoid acids, limonoid glucosides and flavonoid...

  4. Quantification of endogenous metabolites by the postcolumn infused-internal standard method combined with matrix normalization factor in liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Liao, Hsiao-Wei; Chen, Guan-Yuan; Wu, Ming-Shiang; Liao, Wei-Chih; Tsai, I-Lin; Kuo, Ching-Hua

    2015-01-02

    Quantification of endogenous metabolites has enabled the discovery of biomarkers for diagnosis and provided for an understanding of disease etiology. The standard addition and stable isotope labeled-internal standard (SIL-IS) methods are currently the most widely used approaches to quantifying endogenous metabolites, but both have some limitations for clinical measurement. In this study, we developed a new approach for endogenous metabolite quantification by the postcolumn infused-internal standard (PCI-IS) method combined with the matrix normalization factor (MNF) method. MNF was used to correct the difference in MEs between standard solution and biofluids, and PCI-IS additionally tailored the correction of the MEs for individual samples. Androstenedione and testosterone were selected as test articles to verify this new approach to quantifying metabolites in plasma. The repeatability (n=4 runs) and intermediate precision (n=3 days) in terms of the peak area of androstenedione and testosterone at all tested concentrations were all less than 11% relative standard deviation (RSD). The accuracy test revealed that the recoveries were between 95.72% and 113.46%. The concentrations of androstenedione and testosterone in fifty plasma samples obtained from healthy volunteers were quantified by the PCI-IS combined with the MNF method, and the quantification results were compared with the results of the SIL-IS method. The Pearson correlation test showed that the correlation coefficient was 0.98 for both androstenedione and testosterone. We demonstrated that the PCI-IS combined with the MNF method is an effective and accurate method for quantifying endogenous metabolites. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Determination of low levels of perchlorate in lettuce and spinach using ion chromatography-electrospray ionization mass spectrometry (IC-ESI-MS).

    Science.gov (United States)

    Seyfferth, Angelia L; Parker, David R

    2006-03-22

    A sample preparation method was developed to quantify environmentally relevant (low micrograms per liter) concentrations of perchlorate (ClO4(-)) in leafy vegetables using IC-ESI-MS. Lettuce and spinach were macerated, centrifuged, and filtered, and the aqueous extracts were rendered water-clear using a one-step solid-phase extraction method. Total time for extraction and sample preparation was 6 h. Ion suppression was demonstrated and was likely due to unknown organics still present in the extract solution after cleanup. However, this interference was readily eliminated using a Cl(18)O4(-) internal standard at 1 microg/L in all standards and samples. Hydroponically grown perchlorate-free butterhead lettuce was spiked to either 10.3 or 37.7 microg/kg of fresh weight (FW), and recoveries were between 91 and 98% and between 93 and 101%, respectively. Five types of lettuce and spinach from a local grocery store were then analyzed; they contained from 0.6 to 6.4 microg/kg of FW. Spike recoveries using the store-bought samples ranged from 89 to 100%. The method detection limit for perchlorate in plant extracts is 40 ng/L, and the corresponding minimum reporting limit is 200 ng/L or 0.8 microg/kg of FW.

  6. Classification of cultivation locations of Panax quinquefolius L samples using high performance liquid chromatography-electrospray ionization mass spectrometry and chemometric analysis

    Science.gov (United States)

    Panax quinquefolius L (P. quinquefolius L) samples grown in the United States and China were analyzed with high performance liquid chromatography-mass spectrometry (HPLC—MS). Prior to classification, the two-way datasets were subjected to pretreatment including baseline correction and retention tim...

  7. Metabolomics Analysis of Health Functions of Physalis Pubescens L. using by Ultra-performance Liquid Chromatography/Electrospray Ionization Quadruple Time-of-Flight Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    Hang Chu; Hui Sun; Guang-Li Yan; Ai-Hua Zhang; Chang Liu; Hui Dong; Xiang-Cai Meng; Xi-Jun Wang

    2015-01-01

    Herbal medicines may benefit from metabolomics studies, and applying metabolomics may provide answers about which herbal interventions may be effective for individuals, which metabolic processes are triggered, and the subsequent chemical pathways of activity. Physalis pubescens L (PPL) is an herbal fruit for one year living plant and has been developed into healthy function’s food. However, the mechanisms of health functions are still unclear. To comprehensively and holistically assess its anti-fatigue and antioxidant effects, a novel integrative metabolomics approach was applied. In this study, we present metabolomics analysis applying ultra performance liquid chromatography coupled to quadrupole with time-of-flight mass spectrometry (UPLC-Q/TOF-MS) to determine metabolite alterations after oral administration PPL to rats. Fifteen metabolites in urine were identified as potential biomarkers. Pattern analysis of the UPLC-Q/TOF-MS data disclosed that PPL could relieve fatigue rats by ameliorating the disturbance in amino acids metabolism and energy metabolism, alleviating the oxidative stress from reactive oxygen species and the inflammatory damage, and recovering the destructed regulation. Based on these results, we demonstrated that PPL is a promising source of natural anti-fatigue and antioxidants material for use in functional foods and medicines.

  8. Antioxidant activity and identification of bioactive compounds from leaves of Anthocephalus cadamba by ultra-performance liquid chromatography/electrospray ionization quadrupole time of flight mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    Madhu Chandel; Upendra Sharma; Neeraj Kumar; Bikram Singh; Satwinderjeet Kaur

    2012-01-01

    Objective: To evaluate the antioxidant potential of different extract/fractions of Anthocephalus cadamba (A. cadamba) (Roxb.) Miq. (Rubiaceae) and study the tentative identification of their active constituents. Methods: The extract/fractions were screened for antioxidant activity using various in vitro assays viz. DPPH assay, ABTS assay, superoxide anion radical scavenging assay, reducing power assay and plasmid DNA nicking assay. Total phenolic content of extract/fractions was determined by colorimetric method. An ultra-performance LC-electrospray-quadrupole-time of flight mass spectrometry method was used to analyse the active constituents of extract/fractions of A. cadamba. Results: The ethyl acetate fraction was found to be most active fraction in all the assays as compared to other extract/fractions. The IC50 value of ethyl acetate fraction (ETAC fraction) was 21.24 μg/mL, 1.12 μg/mL, 9.68 μg/mL and 57.81 μg/mL in DPPH assay, ABTS assay, reducing power assay and superoxide scavenging assay respectively. All the extract/fractions also showed the potential to protect the plasmid DNA (pBR322) against the attack of hydroxyl radicals generated by Fenton’s reagent. The bioactive compounds were identified by UPLC-ESI-QTOF-MS, by comparing the mass and λmax with literature values. Conclusions: The potential of the extract/fractions to scavenge different free radicals in different systems indicated that they may be useful therapeutic agents for treating radical-related pathologic damage.

  9. Liquid Chromatography-Electrospray Ionization Mass Spectrometry Analysis of Limonoids and Flavonoids in Seeds of Grapefruits, Other Citrus Species, and Dietary Supplements.

    Science.gov (United States)

    Avula, Bharathi; Sagi, Satyanarayanaraju; Wang, Yan-Hong; Wang, Mei; Gafner, Stefan; Manthey, John A; Khan, Ikhlas A

    2016-07-01

    A selective UHPLC-DAD-QToF-MS method was developed to screen grapefruit seeds, and the seeds of other Citrus species for limonoid aglycones, acids, glucosides, and flavonoids. These classes of compounds were identified in positive and negative ion modes over a mass-to-charge range from 100-1500. Accurate mass values, elution times, and fragmentation patterns obtained by QToF-mass spectrometry were used to identify or tentatively characterize the compounds detected in the sample of this study. Limonin was the major limonoid in most of the seeds of Citrus species, followed by nomilin. This analytical method was successfully applied for the analysis of commercial extracts and dietary supplements claiming to contain grapefruit seed extract, or extracts made from the seed and other fruit parts such as the peel or pulp. Many commercial products contained large numbers of flavonoids, indicating the use of peel, pulp, or seed coat. This method also permitted detection of synthetic preservatives such as benzethonium chloride, methylparaben, and triclosan in commercial grapefruit seed extract products. Out of the 17 commercial products analyzed, two contained the synthetic antimicrobial agent benzethonium chloride. Georg Thieme Verlag KG Stuttgart · New York.

  10. Validation of a liquid chromatography-electrospray ionization tandem mass spectrometric method to determine six polyether ionophores in raw, UHT, pasteurized and powdered milk.

    Science.gov (United States)

    Pereira, Mararlene Ulberg; Spisso, Bernardete Ferraz; Jacob, Silvana do Couto; Monteiro, Mychelle Alves; Ferreira, Rosana Gomes; Carlos, Betânia de Souza; da Nóbrega, Armi Wanderley

    2016-04-01

    This study aimed to validate a method developed for the determination of six antibiotics from the polyether ionophore class (lasalocid, maduramicin, monensin, narasin, salinomycin and semduramicin) at residue levels in raw, UHT, pasteurized and powdered milk using QuEChERS extraction and high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS). The validation was conducted under an in-house laboratory protocol that is primarily based on 2002/657/EC Decision, but takes in account the variability of matrix sources. Overall recoveries between 93% and 113% with relative standard deviations up to 16% were obtained under intermediate precision conditions. CCα calculated values did not exceed 20% the Maximum Residue Limit for monensin and 25% the Maximum Levels for all other substances. The method showed to be simple, fast and suitable for verifying the compliance of raw and processed milk samples regarding the limits recommended by Codex Alimentarius and those adopted in European Community for polyether ionophores. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Sensitive measurement of vinorelbine in dog plasma by liquid chromatography-electrospray ionization tandem mass spectrometry utilizing transitions from double-charged precursor ions.

    Science.gov (United States)

    Niwa, Makoto; Kawashiro, Takashi

    2011-04-01

    A sensitive high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for measuring vinorelbine was developed. A 100 µL aliquot of plasma was spiked with deuterium-labeled internal standard and subjected to solid-phase extraction using an Oasis HLB μ-elution plate. Two microliters of the extracted samples was directly injected into LC/MS/MS. Chromatographic separation was achieved on a Capcell Pak C18 UG column (2 × 75 mm) with a gradient elution of methanol (mobile phase B) against 0.05% formic acid in aqueous 10 mm ammonium formate (mobile phase A). The LC flow rate was set to 0.28 mL/min and the gradient (solvent B concentration) was processed from 40 to 90%. In mass spectrometric detection, observation of the reaction from a double-charged precursor ion [M + 2H](2+) (m/z 390) to product ion m/z 122 provided very high sensitivity. The method was validated with a lower limit of detection of 0.2 ng/mL with 0.1 mL of plasma, and the method was used to determine the plasma pharmacokinetics of vinorelbine in dogs. Copyright © 2010 John Wiley & Sons, Ltd.

  12. Concentrations and dissipation of difenoconazole and fluxapyroxad residues in apples and soil, determined by ultrahigh-performance liquid chromatography electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    He, Min; Jia, Chunhong; Zhao, Ercheng; Chen, Li; Yu, Pingzhong; Jing, Junjie; Zheng, Yongquan

    2016-03-01

    A new combined difenoconazole and fluxapyroxad fungicide formulation, as an 11.7 % suspension concentrate (SC), has been introduced as part of a resistance management strategy. The dissipation of difenoconazole and fluxapyroxad applied to apples and the residues remaining in the apples were determined. The 11.7 % SC was sprayed onto apple trees and soil in Beijing, Shandong, and Anhui provinces, China, at an application rate of 118 g a.i. ha(-1), then the dissipation of difenoconazole and fluxapyroxad was monitored. The residual difenoconazole and fluxapyroxad concentrations were determined by ultrahigh-performance liquid chromatography tandem mass spectrometry. The difenoconazole half-lives in apples and soil were 6.2-9.5 and 21.0-27.7 days, respectively. The fluxapyroxad half-lives in apples and soil were 9.4-12.6 and 10.3-36.5 days, respectively. Difenoconazole and fluxapyroxad residues in apples and soil after the 11.7 % SC had been sprayed twice and three times, with 10 days between applications, at 78 and 118 g a.i. ha(-1) were measured. Representative apple and soil samples were collected after the last treatment, at preharvest intervals of 14, 21, and 28 days. The difenoconazole residue concentrations in apples and soil were 0.002-0.052 and 0.002-0.298 mg kg(-1), respectively. The fluxapyroxad residue concentrations in apples and soil were 0.002-0.093 and 0.008-1.219 mg kg(-1), respectively. The difenoconazole and fluxapyroxad residue concentrations in apples were lower than the maximum residue limits (0.5 and 0.8 mg kg(-1), respectively). An application rate of 78 g a.i. ha(-1) is therefore recommended to ensure that treated apples can be considered safe for humans to consume.

  13. Characterization of Steroidal Saponins from Dioscorea villosa and D. cayenensis Using Ultrahigh Performance Liquid Chromatography/Electrospray Ionization Quadrupole Time-of-Flight Mass Spectrometry

    Science.gov (United States)

    Avula, Bharathi; Wang, Yan-Hong; Wang, Mei; Ali, Zulfiqar; Smillie, Troy J.; Zweigenbaum, Jerry; Khan, Ikhlas A.

    2017-01-01

    Yam (Dioscorea spp.) is an important edible tuber plant used for medicinal purposes to promote health and longevity in Chinese tradition. Steroidal saponins were reported to be the major physiologically active constituents in yams. In this current work, the structural characteristics of steroidal saponins in methanolic extracts from dried rhizomes of two Dioscorea species (D. villosa L. and D. cayenensis Lam.) and dietary supplements have been identified and analyzed using UHPLC/QTOF-MS in both negative and positive ion modes. The fragmentation patterns of reference standards were determined and the steroidal saponins in the extracts were identified or tentatively characterized from their retention times and mass spectra. The fragments produced by collision-induced dissociation (CID) revealed the characteristic cleavage of glycosidic bonds, and the fragmentation pattern provided structural information about the sugars. Twenty-one saponins, including four tentatively identified compounds, were detected in the crude extracts of two Dioscorea species. These saponins can be used to distinguish D. villosa from D. cayenensis. For example, asperin and gracillin are found only in D. cayenensis, and dioscoreavilloside A and B and parvifloside are only found in D. villosa. This can be used to determine the presence or absence of D. villosa in commercial products, which may help determine the spiking of plant material, and/or prevent the use of potentially mislabeled or misidentified “Dioscorea” material. The analytical method also provided an alternative, fast method for quality control of Dioscorea species in dietary supplements. Principal component analysis showed that Dioscorea species and commercial products were easily distinguished. From this a partial least squares model was constructed to determine what species are in different products. PMID:24510365

  14. Validation and application of a liquid chromatography-electrospray ionization mass spectrometric method for determination of mazindol in human plasma and urine.

    Science.gov (United States)

    de Oliveira, Marcella Herbstrith; Ferreira, Pâmela Cristina Lukasewicz; Carlos, Graciela; Salazar, Fernanda Rodrigues; Bergold, Ana Maria; Pechansky, Flavio; Limberger, Renata Pereira; Fröehlich, Pedro Eduardo

    2016-01-01

    Even after removal of some stimulants, like fenproporex, amfepramone and mazindol, from Brazilian market, the use of these substances is still high, especially by drivers. Mazindol is the second most used anorectic agent in the world acting as an indirect sympathomimetic agonist, having stimulatory action on central nervous system. Plasma is a good matrix to monitor since it reflects the psychomotor effects of these drugs, but unlike urine has an invasive collection; drug levels and detection time are quite low. The method involved a liquid-liquid extraction of the samples and a LC-MS analysis was fully validated. Method was used to analyze samples of urine and plasma collected from health volunteers in a period of 24h. Metabolite of mazindol was synthesized using alkaline conditions. After validation the method proved to be adequate to analyze samples collected from health volunteers. Method was linear in the concentration range of 0.1-10ng/mL (r=0.9982) for plasma and 5-50ng/mL (r=0.9973) for urine. Analysis of the samples showed that mazindol can be detected after 1h of administration and that concentration levels in urine were always higher than in plasma. Mazindol metabolite was detected only in urine. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Direct injection liquid chromatography/electrospray ionization mass spectrometric horse urine analysis for the quantification and confirmation of threshold substances for doping control. II. Determination of theobromine.

    Science.gov (United States)

    Vonaparti, A; Lyris, E; Panderi, I; Koupparis, M; Georgakopoulos, C

    2009-04-01

    In equine sport, theobromine is prohibited with a threshold level of 2 microg mL(-1) in urine, hence doping control laboratories have to establish quantitative and qualitative methods for its determination. Two simple liquid chromatography/mass spectrometry (LC/MS) methods for the identification and quantification of theobromine were developed and validated using the same sample preparation procedure but different mass spectrometric systems: ion trap mass spectrometry (ITMS) and time-of-flight mass spectrometry (TOFMS). Particle-free diluted urine samples were directly injected into the LC/MS systems, avoiding the time-consuming extraction step. 3-Propylxanthine was used as the internal standard. The tested linear range was 0.75-15 microg mL(-1). Matrix effects were evaluated analyzing calibration curves in water and different fortified horse urine samples. A great variation in the signal of theobromine and the internal standard was observed in different matrices. To overcome matrix effects, a standard additions calibration method was applied. The relative standard deviations of intra- and inter-day analysis were lower than 8.6 and 7.2%, respectively, for the LC/ITMS method and lower than 5.7 and 5.8%, respectively, for the LC/TOFMS method. The bias was less than 8.7% for both methods. The methods were applied to two case samples, demonstrating simplicity, accuracy and selectivity. Copyright (c) 2009 John Wiley & Sons, Ltd.

  16. Determination of vandetanib in human plasma and cerebrospinal fluid by liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS).

    Science.gov (United States)

    Bai, Feng; Johnson, Jennifer; Wang, Fan; Yang, Lei; Broniscer, Alberto; Stewart, Clinton F

    2011-09-01

    A sensitive and precise LC-ESI-MS/MS method for the determination of vandetanib (ZD6474) in human plasma and cerebrospinal fluid (CSF) using [(13)C,d(3)]-ZD6474 as an internal standard (ISTD) was developed and validated. Sample preparation consisted of a simple liquid-liquid extraction with tert-butyl methyl ether containing 0.1% or 0.5% ammonium hydroxide. ZD6474 and ISTD were separated on a Kinetex C18 column (2.6 μm, 50 mm × 2.1 mm) at ambient temperature with an isocratic mobile phase (acetonitrile/10mM ammonium formate=50/50, v/v, at pH 5.0) delivered at 0.11 mL/min. The retention time of both compounds was at 1.60 min in a runtime of three min. Detection was achieved by an API-3200 LC-MS/MS system, monitoring m/z 475.1/112.1 and m/z 479.1/116.2 for vandetanib and ISTD, respectively. The method was linear in the range of 0.25-50 ng/mL (R(2) ≥ 0.990) for the CSF curve and from 1.0 to 3000 ng/mL (R(2) ≥ 0.992) for the plasma curve. The mean recovery for vandetanib was 80%. Within-day and between-day precisions were ≤ 8.8% and ≤ 5.9% for CSF and plasma, respectively. Within-day and between-day accuracies ranged from 95.0 to 98.5% for CSF, and from 104.0 to 108.5% for plasma. Analysis of plasma from six different sources showed no matrix effect for vandetanib (MF=0.98, %CV ≤ 4.97, n=6). This method was successfully applied to the analysis of pharmacokinetic samples from children with brain tumors treated with oral vandetanib. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Analysis of ribo- and deoxyribonucleic acids using ionpair-reversed-phase liquid-chromatography electrospray-mass spectrometry

    International Nuclear Information System (INIS)

    Hoelzl, G.

    2002-10-01

    The fast progress in natural sciences like biology, biochemistry, medicine or genetics make high demands on the analytical chemistry. The on-line coupling of ionpair-reversed phase-liquid chromatography (IP-RP-HPLC) to mass spectrometry (MS) becomes more and more the method of choice for the analysis of biomolecules. The success is based on the introduction of soft ionization methods, like electrospray ionization (ESI), which allows the transfer of intact biopolymers into the gasphase. This combination enables the on-line separation of complex biological mixtures with additional identification of the compounds by their molecular mass. The first part describes the development of a new ionsource, which combines the advantages of a micro-ESI- and a nanospray-source. In combination with additional optimization of the chromatographic conditions the new ionsource showed an improvement of the quality of the spectra by a factor of 5 and a stability of the ionspray by a factor of 2, which resulted in an overall improvement of sensitivity by a factor of 10 for the HPLC-MS system. The second part describes the quality control of synthetic RNA molecules. Using IP-RP-HPLC-ESI-MS it was possible to separate failure sequences and derivatives in raw products of short synthetic RNAs. The derivatives were formed of protecting groups, which were not removed during the deprotection step. The analysis of coupling products of the synthesis of aminoacylated transfer RNAs showed a derivative, which was formed by the addition of the used coupling reagent N-(3-dimethylaminopropyl)N'-ethylcarbodiimide (EDC). The identification of the derivatives led to the optimization of the reaction conditions which resulted in the synthesis of the wanted transfer RNA without any additional derivatives. Another experiment involved the fragmentation of RNA molecules. Tandem mass spectrometry provides the opportunity to determine the sequence of nucleic acids. Fragmentation experiments showed different

  18. Hyphenation of optimized microfluidic sample preparation with nano liquid chromatography for faster and greener alkaloid analysis

    NARCIS (Netherlands)

    Shen, Y.; Beek, van T.A.; Zuilhof, H.; Chen, B.

    2013-01-01

    A glass liquid–liquid extraction (LLE) microchip with three parallel 3.5 cm long and 100 µm wide interconnecting channels was optimized in terms of more environmentally friendly (greener) solvents and extraction efficiency. In addition, the optimized chip was successfully hyphenated with nano-liquid

  19. Ionization

    International Nuclear Information System (INIS)

    2002-01-01

    This document reprints the text of the French by-law from January 8, 2002 relative to the approval and to the controls and verifications of facilities devoted to the ionizing of food products for human beings and animals. The by-law imposes the operators of such facilities to perform measurements and dosimetric verifications all along the ionization process. (J.S.)

  20. High-throughput method for macrolides and lincosamides antibiotics residues analysis in milk and muscle using a simple liquid-liquid extraction technique and liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-MS/MS).

    Science.gov (United States)

    Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Campos Motta, Tanara Magalhães; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara

    2015-11-01

    A fast and simple method for residue analysis of the antibiotics classes of macrolides (erythromycin, azithromycin, tylosin, tilmicosin and spiramycin) and lincosamides (lincomycin and clindamycin) was developed and validated for cattle, swine and chicken muscle and for bovine milk. Sample preparation consists in a liquid-liquid extraction (LLE) with acetonitrile, followed by liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-ESI-MS/MS), without the need of any additional clean-up steps. Chromatographic separation was achieved using a C18 column and a mobile phase composed by acidified acetonitrile and water. The method was fully validated according the criteria of the Commission Decision 2002/657/EC. Validation parameters such as limit of detection, limit of quantification, linearity, accuracy, repeatability, specificity, reproducibility, decision limit (CCα) and detection capability (CCβ) were evaluated. All calculated values met the established criteria. Reproducibility values, expressed as coefficient of variation, were all lower than 19.1%. Recoveries range from 60% to 107%. Limits of detection were from 5 to 25 µg kg(-1).The present method is able to be applied in routine analysis, with adequate time of analysis, low cost and a simple sample preparation protocol. Copyright © 2015. Published by Elsevier B.V.

  1. Ultra trace determination of 31 pesticides in water samples by direct injection-rapid resolution liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Díaz, Laura; Llorca-Pórcel, Julio; Valor, Ignacio

    2008-08-22

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for the detection of pesticides in tap and treated wastewater was developed and validated according to the ISO/IEC 17025:1999. Key features of this method include direct injection of 100 microL of sample, an 11 min separation by means of a rapid resolution liquid chromatography system with a 4.6 mm x 50 mm, 1.8 microm particle size reverse phase column and detection by electrospray ionization (ESI) MS-MS. The limits of detection were below 15 ng L(-1) and correlation coefficients for the calibration curves in the range of 30-2000 ng L(-1) were higher than 0.99. Precision was always below 20% and accuracy was confirmed by external evaluation. The main advantages of this method are direct injection of sample without preparative procedures and low limits of detection that fulfill the requirements established by the current European regulations governing pesticide detection.

  2. Trace analysis of trimethoprim and sulfonamide, macrolide, quinolone, and tetracycline antibiotics in chlorinated drinking water using liquid chromatography electrospray tandem mass spectrometry

    Science.gov (United States)

    Ye, Z.; Weinberg, H.S.; Meyer, M.T.

    2007-01-01

    A multirun analytical method has been developed and validated for trace determination of 24 antibiotics including 7 sulfonamides, 3 macrolides, 7 quinolones, 6 tetracyclines, and trimethoprim in chlorine-disinfected drinking water using a single solid-phase extraction method coupled to liquid chromatography with positive electrospray tandem mass spectrometry detection. The analytes were extracted by a hydrophilic-lipophilic balanced resin and eluted with acidified methanol (0.1% formic acid), resulting in analyte recoveries generally above 90%. The limits of quantitation were mostly below 10 ng/L in drinking water. Since the concentrated sample matrix typically caused ion suppression during electrospray ionization, the method of standard addition was used for quantitation. Chlorine residuals in drinking water can react with some antibiotics, but ascorbic acid was found to be an effective chlorine quenching agent without affecting the analysis and stability of the antibiotics in water. A preliminary occurrence study using this method revealed the presence of some antibiotics in drinking waters, including sulfamethoxazole (3.0-3.4 ng/L), macrolides (1.4-4.9 ng/L), and quinolones (1.2-4.0 ng/L). ?? 2007 American Chemical Society.

  3. Quantitative analysis of N-glycans from human alfa-acid-glycoprotein using stable isotope labeling and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry as tool for pancreatic disease diagnosis

    International Nuclear Information System (INIS)

    Giménez, Estela; Balmaña, Meritxell; Figueras, Joan; Fort, Esther; Bolós, Carme de; Sanz-Nebot, Victòria; Peracaula, Rosa; Rizzi, Andreas

    2015-01-01

    Highlights: • The method enables relative quantitation of hAGP glycans from pathological samples • Pancreatic cancer samples clearly showed an increase of hAGP fucosylated glycans. • Fucosylated glycans could be potential biomarkers for diagnosing pancreatic cancer. • The established method could be extremely useful to find novel glycoprotein biomarkers - Abstract: In this work we demonstrate the potential of glycan reductive isotope labeling (GRIL) using [ 12 C]- and [ 13 C]-coded aniline and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry (μZIC-HILIC-ESI-MS) for relative quantitation of glycosylation variants in selected glycoproteins present in samples from cancer patients. Human α 1 -acid-glycoprotein (hAGP) is an acute phase serum glycoprotein whose glycosylation has been described to be altered in cancer and chronic inflammation. However, it is not clear yet whether some particular glycans in hAGP can be used as biomarker for differentiating between these two pathologies. In this work, hAGP was isolated by immunoaffinity chromatography (IAC) from serum samples of healthy individuals and from those suffering chronic pancreatitis and different stages of pancreatic cancer, respectively. After de-N-glycosylation, relative quantitation of the hAGP glycans was carried out using stable isotope labeling and μZIC-HILIC-ESI-MS analysis. First, protein denaturing conditions prior to PNGase F digestion were optimized to achieve quantitative digestion yields, and the reproducibility of the established methodology was evaluated with standard hAGP. Then, the proposed method was applied to the analysis of the clinical samples (control vs. pathological). Pancreatic cancer samples clearly showed an increase in the abundance of fucosylated glycans as the stage of the disease increases and this was unlike to samples from chronic pancreatitis. The results gained here indicate the mentioned glycan in hAGP as a

  4. Quantitative analysis of N-glycans from human alfa-acid-glycoprotein using stable isotope labeling and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry as tool for pancreatic disease diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Giménez, Estela, E-mail: estelagimenez@ub.edu [Department of Analytical Chemistry, University of Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Balmaña, Meritxell [Biochemistry and Molecular Biology Unit, Department of Biology, University of Girona, Campus Montilivi s/n, 17071 Girona (Spain); Figueras, Joan [Department of Surgery, Dr. Josep Trueta University Hospital, IdlBGi, 17007 Girona (Spain); Fort, Esther [Digestive Unit, Dr. Josep Trueta University Hospital, 17007 Girona (Spain); Bolós, Carme de [Gastroesophagic Cancer Research Group, Research Programme in Cancer, Hospital del Mar Medical Research Institute (IMIM), Dr. Aiguader, 88, 08003 Barcelona (Spain); Sanz-Nebot, Victòria [Department of Analytical Chemistry, University of Barcelona, Diagonal 647, E-08028 Barcelona (Spain); Peracaula, Rosa [Biochemistry and Molecular Biology Unit, Department of Biology, University of Girona, Campus Montilivi s/n, 17071 Girona (Spain); Rizzi, Andreas [Institute of Analytical Chemistry, University of Vienna, Währinger Straße 38, A-1090 Vienna (Austria)

    2015-03-25

    Highlights: • The method enables relative quantitation of hAGP glycans from pathological samples • Pancreatic cancer samples clearly showed an increase of hAGP fucosylated glycans. • Fucosylated glycans could be potential biomarkers for diagnosing pancreatic cancer. • The established method could be extremely useful to find novel glycoprotein biomarkers - Abstract: In this work we demonstrate the potential of glycan reductive isotope labeling (GRIL) using [{sup 12}C]- and [{sup 13}C]-coded aniline and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry (μZIC-HILIC-ESI-MS) for relative quantitation of glycosylation variants in selected glycoproteins present in samples from cancer patients. Human α{sub 1}-acid-glycoprotein (hAGP) is an acute phase serum glycoprotein whose glycosylation has been described to be altered in cancer and chronic inflammation. However, it is not clear yet whether some particular glycans in hAGP can be used as biomarker for differentiating between these two pathologies. In this work, hAGP was isolated by immunoaffinity chromatography (IAC) from serum samples of healthy individuals and from those suffering chronic pancreatitis and different stages of pancreatic cancer, respectively. After de-N-glycosylation, relative quantitation of the hAGP glycans was carried out using stable isotope labeling and μZIC-HILIC-ESI-MS analysis. First, protein denaturing conditions prior to PNGase F digestion were optimized to achieve quantitative digestion yields, and the reproducibility of the established methodology was evaluated with standard hAGP. Then, the proposed method was applied to the analysis of the clinical samples (control vs. pathological). Pancreatic cancer samples clearly showed an increase in the abundance of fucosylated glycans as the stage of the disease increases and this was unlike to samples from chronic pancreatitis. The results gained here indicate the mentioned glycan in h

  5. A Simple Defined Medium for the Production of True Diketopiperazines in Xylella fastidiosa and Their Identification by Ultra-Fast Liquid Chromatography-Electrospray Ionization Ion Trap Mass Spectrometry.

    Science.gov (United States)

    Silva, Michelli Massaroli da; Andrade, Moacir Dos Santos; Bauermeister, Anelize; Merfa, Marcus Vinícius; Forim, Moacir Rossi; Fernandes, João Batista; Vieira, Paulo Cezar; Silva, Maria Fátima das Graças Fernandes da; Lopes, Norberto Peporine; Machado, Marcos Antônio; Souza, Alessandra Alves de

    2017-06-13

    Diketopiperazines can be generated by non-enzymatic cyclization of linear dipeptides at extreme temperature or pH, and the complex medium used to culture bacteria and fungi including phytone peptone and trypticase peptone, can also produce cyclic peptides by heat sterilization. As a result, it is not always clear if many diketopiperazines reported in the literature are artifacts formed by the different complex media used in microorganism growth. An ideal method for analysis of these compounds should identify whether they are either synthesized de novo from the products of primary metabolism and deliver true diketopiperazines. A simple defined medium ( X. fastidiosa medium or XFM) containing a single carbon source and no preformed amino acids has emerged as a method with a particularly high potential for the grown of X. fastidiosa and to produce genuine natural products. In this work, we identified a range of diketopiperazines from X. fastidiosa 9a5c growth in XFM, using Ultra-Fast Liquid Chromatography coupled with mass spectrometry. Diketopiperazines are reported for the first time from X. fastidiosa , which is responsible for citrus variegated chlorosis. We also report here fatty acids from X. fastidiosa , which were not biologically active as diffusible signals, and the role of diketopiperazines in signal transduction still remains unknown.

  6. Resveratrol and its oligomers from wine grapes are selective (1)O2 quenchers: mechanistic implication by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry and theoretical calculation.

    Science.gov (United States)

    Jiang, Li-Yan; He, Shan; Jiang, Ke-Zhi; Sun, Cui-Rong; Pan, Yuan-Jiang

    2010-08-25

    Resveratrol and its oligomers, abundantly present in wine grapes, are believed to be effective phytoalexins for the phenomenon "French paradox" partially by virtue of their powerful antiradical properties. EPR spin-trapping technique was utilized, demonstrating all polyphenols were selective (1)O2 quenchers but not effective (•)OH and O2(•¯) scavengers. On the basis of the HPLC-ESI-MS(2) analysis for the simulated reactions of polyphenols with (1)O2, the molecular weights of the resulting photochemical products were 14 or 28 Da higher than those of their substrates. No fragment C2H2O (42 Da), which was rather distinctive of the resorcinol rings in these cases, had been observed, whereas their MS/MS spectra displayed characteristic neutral fragments including carbon monoxide (CO, 28 Da) and 2-hydroxy[1,4]benzoquinone (C6H4O3, 124 Da). Finally, PM3 semiempirical calculations and HR-FTICR-MS experiments were performed, supporting the assertion that their quenching mechanism involved physical and chemical pathways. Chemical quenching underwent an endoperoxide intermediate form to generate quinones.

  7. Development of an ultrahigh-performance liquid chromatography-electrospray ionization-tandem mass spectrometry method for the simultaneous determination of salicylic acid, jasmonic acid, and abscisic acid in rose leaves.

    Science.gov (United States)

    Bosco, Renato; Daeseleire, Els; Van Pamel, Els; Scariot, Valentina; Leus, Leen

    2014-07-09

    This paper describes a method to detect and quantitate the endogenous plant hormones (±)-2-cis-4-trans-abscisic acid, (-)-jasmonic acid, and salicylic acid by means of ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) in hybrid rose leaf matrices. Deuterium-labeled [(2)H6] (+)-2-cis-4-trans-abscisic acid, [(2)H6] (±)-jasmonic acid, and [(2)H4]-salicylic acid were used as internal standards. Rose samples (10 mg) were extracted with methanol/water/acetic acid (10:89:1) and subsequently purified on an Oasis MCX 1 cm(3) Vac SPE cartridge. Performance characteristics were validated according to Commission Decision 2002/657/EC. Recovery, repeatability, and within-laboratory reproducibility were acceptable for all phytohormones tested at three different concentrations. The decision limit and detection capability for (±)-2-cis-4-trans-abscisic acid, (-)-jasmonic acid, and salicylic acid were 0.0075 and 0.015 μg/g, 0.00015 and 0.00030 μg/g, and 0.0089 and 0.018 μg/g, respectively. Matrix effects (signal suppression or enhancement) appeared to be high for all substances considered, implying the need for quantitation based on matrix-matched calibration curves.

  8. Evaluation of Offline Tandem and Online Solid-Phase Extraction with Liquid Chromatography/Electrospray Ionization-Mass Spectrometry for Analysis of Antibiotics in Ambient Water and Comparison to an Independent Method

    Science.gov (United States)

    Meyer, M.T.; Lee, E.A.; Ferrell, G.M.; Bumgarner, J.E.; Varns, Jerry

    2007-01-01

    This report describes the performance of an offline tandem solid-phase extraction (SPE) method and an online SPE method that use liquid chromatography/mass spectrometry for the analysis of 23 and 35 antibiotics, respectively, as used in several water-quality surveys conducted since 1999. In the offline tandem SPE method, normalized concentrations for the quinolone, macrolide, and sulfonamide antibiotics in spiked environmental samples averaged from 81 to 139 percent of the expected spiked concentrations. A modified standard-addition technique was developed to improve the quantitation of the tetracycline antibiotics, which had 'apparent' concentrations that ranged from 185 to 1,200 percent of their expected spiked concentrations in matrix-spiked samples. In the online SPE method, normalized concentrations for the quinolone, macrolide, sulfonamide, and tetracycline antibiotics in matrix-spiked samples averaged from 51 to 142 percent of their expected spiked concentrations, and the beta-lactam antibiotics in matrix-spiked samples averaged from 22 to 76 percent of their expected spiked concentration. Comparison of 44 samples analyzed by both the offline tandem SPE and online SPE methods showed 50 to 100 percent agreement in sample detection for overlapping analytes and 68 to 100 percent agreement in a presence-absence comparison for all analytes. The offline tandem and online SPE methods were compared to an independent method that contains two overlapping antibiotic compounds, sulfamethoxazole and trimethoprim, for 96 and 44 environmental samples, respectively. The offline tandem SPE showed 86 and 92 percent agreement in sample detection and 96 and 98 percent agreement in a presence-absence comparison for sulfamethoxazole and trimethoprim, respectively. The online SPE method showed 57 and 56 percent agreement in sample detection and 72 and 91 percent agreement in presence-absence comparison for sulfamethoxazole and trimethoprim, respectively. A linear regression with an R2 of 0.91 was obtained for trimethoprim concentrations, and an R2 of 0.35 was obtained for sulfamethoxazole concentrations determined from samples analyzed by the offline tandem SPE and online SPE methods. Linear regressions of trimethoprim and sulfamethoxazole concentrations determined from samples analyzed by the offline tandem SPE method and the independent M3 pharmaceutical method yielded R2 of 0.95 and 0.87, respectively. Regressed comparison of the offline tandem SPE method to the online SPE and M3 methods showed that the online SPE method gave higher concentrations for sulfamethoxazole and trimethoprim than were obtained from the offline tandem SPE or M3 methods.

  9. Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Chen, Weiqi; Wang, Lifei; Van Berkel, Gary J; Kertesz, Vilmos; Gan, Jinping

    2016-03-25

    Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites were studied. Major organs (brain, lung, liver, kidney and muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed the same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. In addition, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. A Simple Defined Medium for the Production of True Diketopiperazines in Xylella fastidiosa and Their Identification by Ultra-Fast Liquid Chromatography-Electrospray Ionization Ion Trap Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Michelli Massaroli da Silva

    2017-06-01

    Full Text Available Diketopiperazines can be generated by non-enzymatic cyclization of linear dipeptides at extreme temperature or pH, and the complex medium used to culture bacteria and fungi including phytone peptone and trypticase peptone, can also produce cyclic peptides by heat sterilization. As a result, it is not always clear if many diketopiperazines reported in the literature are artifacts formed by the different complex media used in microorganism growth. An ideal method for analysis of these compounds should identify whether they are either synthesized de novo from the products of primary metabolism and deliver true diketopiperazines. A simple defined medium (X. fastidiosa medium or XFM containing a single carbon source and no preformed amino acids has emerged as a method with a particularly high potential for the grown of X. fastidiosa and to produce genuine natural products. In this work, we identified a range of diketopiperazines from X. fastidiosa 9a5c growth in XFM, using Ultra-Fast Liquid Chromatography coupled with mass spectrometry. Diketopiperazines are reported for the first time from X. fastidiosa, which is responsible for citrus variegated chlorosis. We also report here fatty acids from X. fastidiosa, which were not biologically active as diffusible signals, and the role of diketopiperazines in signal transduction still remains unknown.

  11. Determination of the appetite suppressant P57 in Hoodia gordonii plant extracts and dietary supplements by liquid chromatography/electrospray ionization mass spectrometry (LC-MSD-TOF) and LC-UV methods.

    Science.gov (United States)

    Avula, Bharathi; Wang, Yan-Hong; Pawar, Rahul S; Shukla, Yatin J; Schaneberg, Brian; Khan, Ikhlas A

    2006-01-01

    Hoodia gordonii is traditionally used in South Africa for its appetite suppressant properties. P57AS3 (P57), an oxypregnane steroidal glycoside, is the only reported active constituent from this plant as an appetite suppressant. Effective quality control of these extracts or products requires rapid methods to determine P57 content. New methods of liquid chromatography/mass spectrometry (LC/MS) and LC-UV for analysis of P57 from H. gordonii have been developed. The quantitative determination of P57 was achieved with a Phenomenex Gemini (Torrance, CA) reversed-phase column using gradient mobile phase of water and acetonitrile, both containing 0.1% acetic acid. The method was validated for linearity, repeatability, and limits of detection and quantification. Good results were obtained in terms of repeatability (relative standard deviation <5.0%) and recovery (98.5-103.5%). The developed methods were applied to the determination of P57 for H. gordonii plant samples, one related genus (Opuntia ficus-indica), and dietary supplements that claim to contain H. gordonii.

  12. Ultra(high)-pressure liquid chromatography-electrospray ionization-time-of-flight-ion mobility-high definition mass spectrometry for the rapid identification and structural characterization of flavonoid glycosides from cauliflower waste.

    Science.gov (United States)

    Gonzales, Gerard Bryan; Raes, Katleen; Coelus, Sofie; Struijs, Karin; Smagghe, Guy; Van Camp, John

    2014-01-03

    In this paper, a strategy for the detection and structural elucidation of flavonoid glycosides from a complex matrix in a single chromatographic run using U(H)PLC-ESI-IMS-HDMS/MS(E) is presented. This system operates using alternative low and high energy voltages that is able to perform the task of conventional MS/MS in a data-independent way without re-injection of the sample, which saves analytical time. Also, ion mobility separation (IMS) was employed as an additional separation technique for compounds that are co-eluting after U(H)PLC separation. First, the fragmentation of flavonoid standards were analyzed and criteria was set for structural elucidation of flavonoids in a plant extract. Based on retention times, UV spectra, exact mass, and MS fragment characteristics, such as abundances of daughter ions and the presence of radical ions ([Y0-H](-)), a total 19 flavonoid glycosides, of which 8 non-acylated and 11 acylated, were detected and structurally characterized in a cauliflower waste extract. Kaempferol and quercetin were the main aglycones detected while sinapic and ferulic acid were the main phenolic acids. C-glycosides were also found although their structure could not be elucidated. The proposed method can be used as a rapid screening test for flavonoid identification and for routine analysis of plant extracts, such as these derived from cauliflower waste. The study also confirms that agroindustrial wastes, such as cauliflower leaves, could be seen as a valuable source of different bioactive phenolic compounds. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Fabrication of magnetic nano liquid metal fluid through loading of Ni nanoparticles into gallium or its alloy

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Mingfeng; Gao, Yunxia [Key Lab of Cryogenics and Beijing Key Lab of CryoBiomedical Engineering, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190 (China); Liu, Jing, E-mail: jliu@mail.ipc.ac.cn [Key Lab of Cryogenics and Beijing Key Lab of CryoBiomedical Engineering, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190 (China); Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084 (China)

    2014-03-15

    In this study, Ni nanoparticles were loaded into the partially oxidized gallium and its alloys to fabricate desired magnetic nanofluid. It was disclosed that the Ni nanoparticles sharply increased the freezing temperature and latent heat of the obtained magnetic nano liquid metal fluid, while the melting process was less affected. For the gallium sample added with 10 vol% coated Ni particles, a hysteresis loop was observed and the magnetization intensity decreased with the increase of the temperature. The slope for the magnetization-temperature curve within 10–30 K was about 20 times of that from 40 K to 400 K. Further, the dynamic impact experiments of striking magnetic liquid metal droplets on the magnet revealed that the regurgitating of the leading edge of the liquid disk and the subsequent wave that often occurred in the gallium-indium droplets would disappear for the magnetic fluids case due to attraction force of the magnet. - Graphical abstract: High speed videos for the impact of striking GaIn{sub 24.5} based magnetic liquid metal droplets on a magnet plate. - Highlights: • A feasible way to fabricate magnetic nano liquid metal fluid was presented. • Ni nanoparticles sharply increased freezing temperature and latent heat of magnetic nanofluid. • A hysteresis loop phenomenon was observed for the magnetic nanofluid. • Temperature dependent magnetization spanning from 10 K to 400 K was measured. • Impact phenomena of striking magnetic droplets on magnet were disclosed.

  14. Quantitative Caffeine Analysis Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Deibel, Michael A. [Earlham College; Tomkins, Bruce A [ORNL; Van Berkel, Gary J [ORNL

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  15. Coupling of gas chromatography and electrospray ionization high resolution mass spectrometry for the analysis of anabolic steroids as trimethylsilyl derivatives in human urine.

    Science.gov (United States)

    Cha, Eunju; Jeong, Eun Sook; Cha, Sangwon; Lee, Jaeick

    2017-04-29

    In this study, gas chromatography (GC) was interfaced with high resolution mass spectrometry (HRMS) with electrospray ionization source (ESI) and the relevant parameters were investigated to enhance the ionization efficiency. In GC-ESI, the distances (x-, y- and z) and angle between the ESI needle, GC capillary column and MS orifice were set to 7 (x-distance), 4 (y-distance), and 1 mm (z-distance). The ESI spray solvent, acid modifier and nebulizer gas flow were methanol, 0.1% formic acid and 5 arbitrary units, respectively. Based on these results, analytical conditions for GC-ESI/HRMS were established. In particular, the results of spray solvent flow indicated a concentration-dependent mechanism (peak dilution effect), and other parameters also greatly influenced the ionization performance. The developed GC-ESI/HRMS was then applied to the analysis of anabolic steroids as trimethylsilyl (TMS) derivatives in human urine to demonstrate its application. The ionization profiles of TMS-derivatized steroids were investigated and compared with those of underivatized steroids obtained from gas chromatography-electrospray ionization/mass spectrometry (GC-ESI/MS) and liquid chromatography-electrospray ionization/mass spectrometry (LC-ESI/MS). The steroids exhibited ionization profiles based on their structural characteristics, regardless of the analyte phase or derivatization. Groups I and II with conjugated or unconjugated keto functional groups at C3 generated the [M+H] + and [M+H-TMS] + ions, respectively. On the other hand, Groups III and IV gave rise to the characteristic fragment ions [M+H-TMS-H 2 O] + and [M+H-2TMS-H 2 O] + , corresponding to loss of a neutral TMS·H 2 O moiety from the protonated molecular ion by in-source dissociation. To the best of our knowledge, this is the first study to successfully ionize and analyze steroids as TMS derivatives using ESI coupled with GC. The present system has enabled the ionization of TMS derivatives under ESI conditions

  16. Carbon Nanotube Fiber Ionization Mass Spectrometry: A Fundamental Study of a Multi-Walled Carbon Nanotube Functionalized Corona Discharge Pin for Polycyclic Aromatic Hydrocarbons Analysis

    Science.gov (United States)

    Nahan, Keaton S.; Alvarez, Noe; Shanov, Vesselin; Vonderheide, Anne

    2017-09-01

    Mass spectrometry continues to tackle many complicated tasks, and ongoing research seeks to simplify its instrumentation as well as sampling. The desorption electrospray ionization (DESI) source was the first ambient ionization source to function without extensive gas requirements and chromatography. Electrospray techniques generally have low efficiency for ionization of nonpolar analytes and some researchers have resorted to methods such as direct analysis in real time (DART) or desorption atmospheric pressure chemical ionization (DAPCI) for their analysis. In this work, a carbon nanotube fiber ionization (nanoCFI) source was developed and was found to be capable of solid phase microextraction (SPME) of nonpolar analytes as well as ionization and sampling similar to that of direct probe atmospheric pressure chemical ionization (DP-APCI). Conductivity and adsorption were maintained by utilizing a corona pin functionalized with a multi-walled carbon nanotube (MWCNT) thread. Quantitative work with the nanoCFI source with a designed corona discharge pin insert demonstrated linearity up to 0.97 (R2) of three target PAHs with phenanthrene internal standard. [Figure not available: see fulltext.

  17. Quantitative Thin-Layer Chromatography/Mass Spectrometry Analysis of Caffeine Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Deibel, Michael A. [Earlham College; Tomkins, Bruce A [ORNL; Van Berkel, Gary J [ORNL

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  18. Tear proteomic analysis of patients with type 2 diabetes and dry eye syndrome by two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Li, Bing; Sheng, Minjie; Xie, Liqi; Liu, Feng; Yan, Guoquan; Wang, Weifang; Lin, Anjuan; Zhao, Fei; Chen, Yihui

    2014-01-09

    Diabetes mellitus has been shown to be associated with and complicated by dry eye syndrome. We sought to examine and compare the tear film proteome of type 2 diabetic patients with or without dry eye syndrome and normal subjects using two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry (MS)-based proteomics. Tears were collected from eight type 2 diabetes patients with dry eye syndrome, eight type 2 diabetes patients without dry eye syndrome, and eight normal subjects. Tear breakup time (BUT) was determined, and tear proteins were prepared and analyzed using two-dimensional strong cation-exchange/reversed-phase nano-scale liquid chromatography MS. All MS/MS spectra were identified by using SEQUEST against the human International Protein Index (IPI) database and the relative abundance of individual proteins was assessed by spectral counting. Tear BUT was significantly lower in patients with diabetes and dry eye syndrome than in patients with diabetes only and normal subjects. Analysis of spectral counts of tear proteins showed that, compared to healthy controls, patients with diabetes and dry eye syndrome had increased expression of apoptosis-related proteins, like annexin A1, and immunity- and inflammation-related proteins, including neutrophil elastase 2 and clusterin, and glycometabolism-related proteins, like apolipoprotein A-II. Dry eye syndrome in diabetic patients is associated with aberrant expression of tear proteins, and the findings could lead to identification of novel pathways for therapeutic targeting and new diagnostic markers.

  19. Ionizing and non-ionizing radiations

    International Nuclear Information System (INIS)

    1994-01-01

    The monograph is a small manual to get a knowledge of ionizing and non-ionizing radiations. The main chapters are: - Electromagnetic radiations - Ionizing and non-ionizing radiations - Non-ionizing electromagnetic radiations - Ionizing electromagnetic radiation - Other ionizing radiations - Ionizing radiation effects - The Nuclear Safety Conseil

  20. Proteomic analysis of tears following acupuncture treatment for menopausal dry eye disease by two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Liu, Qingyu; Liu, Junling; Ren, Chengda; Cai, Wenting; Wei, Qingquan; Song, Yi; Yu, Jing

    2017-01-01

    The purpose of this study was to investigate whether acupuncture is effective at treating dry eye disease among postmenopausal women and to identify the possible mechanisms. Twenty-eight postmenopausal women with dry eye disease were randomly divided into two groups: an acupuncture plus artificial tears (AC + AT) group and an artificial tears (AT) only group. After baseline examination of clinical parameters and tear sample collection, each patient received the designated modality of topical therapy for 2 months. Post-treatment documentation of clinical parameters was recorded, and tear samples were collected. Tear samples from the AC + AT group were subjected to two-dimensional nano-liquid chromatography coupled with tandem mass spectrometry (2D nano-LC-MS/MS). Western blot analysis was also performed on tear samples from both groups. After treatment, the Ocular Surface Disease Index scores, symptom assessment scores, scores of sign assessment, and tear break-up time were significantly improved in both groups ( P =0.000). Symptom assessment scores were significantly improved in the AC + AT group ( P =0.000) compared with the AT group. 2D nano-LC-MS/MS identified 2,411 proteins, among which 142 were downregulated and 169 were upregulated. After combined AC + AT treatment, the abundance of secreted proteins was increased, whereas that of cytoplasmic proteins decreased (Pearson's χ 2 test, P =0.000, P =0.000, respectively). Proteins involved in immunity and regulation were also more abundant (Pearson's χ 2 test, P =0.040, P =0.016, respectively), while components and proliferation-related proteins were downregulated (Pearson's χ 2 test, P =0.003, P =0.011, respectively). AC + AT treatment increased protein synthesis and secretion, and improved clinical symptoms. These results indicate that acupuncture may be a complimentary therapy for treating postmenopausal dry eye disease.

  1. Isolation and characterization of wild-type lipoxygenase LOX(Psa)1 from Pleurotus sapidus.

    Science.gov (United States)

    Plagemann, Ina; Krings, Ulrich; Berger, Ralf G

    2014-01-01

    The lipoxygenase LOX(Psa) 1 of Pleurotus sapidus, originally investigated because of its ability to oxidize (+)-valencene to the valuable grapefruit aroma (+)-nootkatone, was isolated from the peptidase-rich lyophilisate using a three-step purification scheme including preparative isoelectric focusing and chromatographic techniques. Nano-liquid chromatography electrospray ionization tandem mass spectrometry (nLC-ESI-MS/MS) of the purified enzyme and peptide mass fingerprint analysis gave 38 peptides of the lipoxygenase from P. sapidus. Nearly 50% of the 643 amino acids long sequence encoded by the cDNA was covered. Both terminal peptides of the native LOX(Psa) 1 were identified by de novo sequencing, and the postulated molecular mass of 72.5 kDa was confirmed. With linoleic acid as the substrate, the LOX(Psa)1 showed a specific activity of 113 U mg(-1) and maximal activity at pH 7.0 and 30 degrees C, respectively.

  2. Ionizing radiation

    International Nuclear Information System (INIS)

    Kruger, J.

    1989-01-01

    Ionizing radiation results in biological damage that differs from other hazardous substances and is highly dangerous to man. Ionizing radiation cannot be perceived by man's sense organs and the biological damage cannot be detected immediately afterwards (except in very high doses). Every human being is exposed to low doses of radiation. The structure of the atom; sources of ionizing radiation; radiation units; biological effects; norms for radiation protection; and the national control in South Africa are discussed. 1 fig., 5 refs

  3. Ionizing radiations

    International Nuclear Information System (INIS)

    Anon.

    1999-01-01

    This is an update about the radiological monitoring in base nuclear installations. A departmental order of the 23. march 1999 (J.O.28. april, p.6309) determines the enabling rules by the Office of Protection against Ionizing Radiations of person having at one's disposal the results with names of individual exposure of workers put through ionizing radiations. (N.C.)

  4. Ionization chambers

    International Nuclear Information System (INIS)

    Boag, J.W.

    1987-01-01

    Although a variety of solid-state and chemical methods for measuring radiation dose have been developed in recent decades and calorimetry can now provide an absolute standard of reference, ionization dosimetry retains its position as the most widely used, most convenient, and, in most situations, most accurate method of measuring either exposure or absorbed dose. The ionization chamber itself is the central element in this system of dosimetry. In this chapter the principles governing the construction and operation of ionization chambers of various types are examined. Since the ionization chambers now in general use are nearly all of commercial manufacture, the emphasis is on operating characteristics and interpretation of measurements rather than on details of construction, although some knowledge of the latter is often required when applying necessary corrections to the measured quantities. Examples are given of the construction of typical chambers designed for particular purposes, and the methods of calibrating them are discussed

  5. Calcium - ionized

    Science.gov (United States)

    ... diuretics Thrombocytosis (high platelet count) Tumors Vitamin A excess Vitamin D excess Lower-than-normal levels may be due to: Hypoparathyroidism Malabsorption Osteomalacia Pancreatitis Renal failure Rickets Vitamin D deficiency Alternative Names Free calcium; Ionized calcium ...

  6. Ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1980-01-01

    A safe and reliable apparatus for detecting products of combustion and aerosols in the atmosphere was developed which uses a beta source. It is easy to adjust for optimum performance. The ionization detector comprises a double chamber; one of the chambers is the basic sensing chamber. The sensing chamber is ported to both the secondary chambers to account for slow ambient changes in the atmosphere outside of the chamber. The voltages from the ionization chamber are adjusted with electrodes in each chamber. The ionization chamber contains baffles to direct the air to be sensed as well as an electrostatic screen. A unique electronic circuit provides an inexpensive and reliable means for detecting the signal change which occurs in the ionization chamber. The decision level of the alarm circuit can be adjusted to allow for any desired sensitivity. (D.N.)

  7. Collisional ionization

    International Nuclear Information System (INIS)

    Arnaud, M.

    1985-07-01

    In low density, thin plasmas (such as stellar coronae, interstellar medium, intracluster medium) the ionization process is governed by collision between electrons and ions in their ground state. In view of the recent improvements we thought an updating of ionization rates was really needed. The work is based on both experimental data and theoretical works and give separate estimates for the direct and autoionization rates

  8. Ionization chamber

    International Nuclear Information System (INIS)

    Jilbert, P.H.

    1975-01-01

    The invention concerns ionization chambers with particular reference to air-equivalent ionization chambers. In order to ensure that similar chambers have similar sensitivities and responses the surface of the chamber bounding the active volume carries a conducting material, which may be a colloidal graphite, arranged in the form of lines so that the area of the conducting material occupies only a small proportion of the area of said surface. (U.S.)

  9. A comprehensive high-resolution mass spectrometry approach for characterization of metabolites by combination of ambient ionization, chromatography and imaging methods.

    Science.gov (United States)

    Berisha, Arton; Dold, Sebastian; Guenther, Sabine; Desbenoit, Nicolas; Takats, Zoltan; Spengler, Bernhard; Römpp, Andreas

    2014-08-30

    An ideal method for bioanalytical applications would deliver spatially resolved quantitative information in real time and without sample preparation. In reality these requirements can typically not be met by a single analytical technique. Therefore, we combine different mass spectrometry approaches: chromatographic separation, ambient ionization and imaging techniques, in order to obtain comprehensive information about metabolites in complex biological samples. Samples were analyzed by laser desorption followed by electrospray ionization (LD-ESI) as an ambient ionization technique, by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging for spatial distribution analysis and by high-performance liquid chromatography/electrospray ionization mass spectrometry (HPLC/ESI-MS) for quantitation and validation of compound identification. All MS data were acquired with high mass resolution and accurate mass (using orbital trapping and ion cyclotron resonance mass spectrometers). Grape berries were analyzed and evaluated in detail, whereas wheat seeds and mouse brain tissue were analyzed in proof-of-concept experiments. In situ measurements by LD-ESI without any sample preparation allowed for fast screening of plant metabolites on the grape surface. MALDI imaging of grape cross sections at 20 µm pixel size revealed the detailed distribution of metabolites which were in accordance with their biological function. HPLC/ESI-MS was used to quantify 13 anthocyanin species as well as to separate and identify isomeric compounds. A total of 41 metabolites (amino acids, carbohydrates, anthocyanins) were identified with all three approaches. Mass accuracy for all MS measurements was better than 2 ppm (root mean square error). The combined approach provides fast screening capabilities, spatial distribution information and the possibility to quantify metabolites. Accurate mass measurements proved to be critical in order to reliably combine data from different MS

  10. Ionizing radiations

    International Nuclear Information System (INIS)

    Newton, W.

    1984-01-01

    The purpose of this article is to simplify some of the relevant points of legislation, biological effects and protection for the benefit of the occupational health nurse not familiar with the nuclear industries. The subject is dealt with under the following headings; Understanding atoms. What is meant by ionizing radiation. Types of ionizing radiation. Effects of radiation: long and short term somatic effects, genetic effects. Control of radiation: occupational exposure, women of reproductive age, medical aspects, principles of control. The occupational health nurse's role. Emergency arrangements: national arrangements for incidents involving radiation, action to be taken by the nurse. Decontamination procedures: external and internal contamination. (U.K.)

  11. III. Penning ionization, associative ionization and chemi-ionization processes

    International Nuclear Information System (INIS)

    Cermak, V.

    1975-01-01

    Physical mechanisms of three important ionization processes in a cold plasma and the methods of their experimental study are discussed. An apparatus for the investigation of the Penning ionization using ionization processes of long lived metastable rare gas atoms is described. Methods of determining interaction energies and ionization rates from the measured energy spectra of the originating electrons are described and illustrated by several examples. Typical associative ionization processes are listed and the ionization rates are compared with those of the Penning ionization. Interactions with short-lived excited particles and the transfer of excitation without ionization are discussed. (J.U.)

  12. Ionizing radiation

    International Nuclear Information System (INIS)

    Dennis, J.A.

    1982-01-01

    The subject is discussed under the headings: characteristics of ionizing radiations; biological effects; comparison of radiation and other industrial risks; principles of protection; cost-benefit analysis; dose limits; the control and monitoring of radiation; reference levels; emergency reference levels. (U.K.)

  13. Ionizing radiation

    Science.gov (United States)

    Tobias, C. A.; Grigoryev, Y. G.

    1975-01-01

    The biological effects of ionizing radiation encountered in space are considered. Biological experiments conducted in space and some experiences of astronauts during space flight are described. The effects of various levels of radiation exposure and the determination of permissible dosages are discussed.

  14. Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of antazoline in human plasma.

    Science.gov (United States)

    Giebułtowicz, Joanna; Kojro, Grzegorz; Piotrowski, Roman; Kułakowski, Piotr; Wroczyński, Piotr

    2016-09-05

    Cloud-point extraction (CPE) is attracting increasing interest in a number of analytical fields, including bioanalysis, as it provides a simple, safe and environmentally-friendly sample preparation technique. However, there are only few reports on the application of this extraction technique in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this study, CPE was used for the isolation of antazoline from human plasma. To date, only one method of antazoline isolation from plasma exists-liquid-liquid extraction (LLE). The aim of this study was to prove the compatibility of CPE and LC-ESI-MS/MS and the applicability of CPE to the determination of antazoline in spiked human plasma and clinical samples. Antazoline was isolated from human plasma using Triton X-114 as a surfactant. Xylometazoline was used as an internal standard. NaOH concentration, temperature and Triton X-114 concentration were optimized. The absolute matrix effect was carefully investigated. All validation experiments met international acceptance criteria and no significant relative matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples. The determination of antazoline concentration in human plasma in the range 10-2500ngmL(-1) by the CPE method led to results which are equivalent to those obtained by the widely used liquid-liquid extraction method. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. An ultrahigh-performance liquid chromatography method with electrospray ionization tandem mass spectrometry for simultaneous quantification of five phytohormones in medicinal plant Glycyrrhiza uralensis under abscisic acid stress.

    Science.gov (United States)

    Xiang, Yu; Song, Xiaona; Qiao, Jing; Zang, Yimei; Li, Yanpeng; Liu, Yong; Liu, Chunsheng

    2015-07-01

    An efficient simplified method was developed to determine multiple classes of phytohormones simultaneously in the medicinal plant Glycyrrhiza uralensis. Ultrahigh-performance liquid chromatography electrospray ionization tandem mass spectrometry (UPLC/ESI-MS/MS) with multiple reaction monitoring (MRM) in negative mode was used for quantification. The five studied phytohormones are gibberellic acid (GA3), abscisic acid (ABA), jasmonic acid (JA), indole-3-acetic acid, and salicylic acid (SA). Only 100 mg of fresh leaves was needed, with one purification step based on C18 solid-phase extraction. Cinnamic acid was chosen as the internal standard instead of isotope-labeled internal standards. Under the optimized conditions, the five phytohormones with internal standard were separated within 4 min, with good linearities and high sensitivity. The validated method was applied to monitor the spatial and temporal changes of the five phytohormones in G. uralensis under ABA stress. The levels of GA3, ABA, JA, and SA in leaves of G. uralensis were increased at different times and with different tendencies in the reported stress mode. These changes in phytohormone levels are discussed in the context of a possible feedback regulation mechanism. Understanding this mechanism will provide a good chance of revealing the mutual interplay between different biosynthetic routes, which could further help elucidate the mechanisms of effective composition accumulation in medicinal plants.

  16. Direct determination of N-methyl-2-pyrrolidone metabolites in urine by HPLC-electrospray ionization-MS/MS using deuterium-labeled compounds as internal standard.

    Science.gov (United States)

    Suzuki, Yoshihiro; Endo, Yoko; Ogawa, Masanori; Yamamoto, Shinobu; Takeuchi, Akito; Nakagawa, Tomoo; Onda, Nobuhiko

    2009-11-01

    N-methyl-2-pyrrolidone (NMP) has been used in many industries and biological monitoring of NMP exposure is preferred to atmospheric monitoring in occupational health. We developed an analytical method that did not include solid phase extraction (SPE) but utilized deuterium-labeled compounds as internal standard for high-performance liquid chromatography-electrospray ionization-mass spectrometry using a C30 column. Urinary concentrations of NMP and its known metabolites 5-hydoxy-N-methyl-2-pyrrolidone (5-HNMP), N-methyl-succinimide (MSI), and 2-hydroxy-N-methylsuccinimide (2-HMSI) were determined in a single run. The method provided baseline separation of these compounds. Their limits of detection in 10-fold diluted urine were 0.0001, 0.006, 0.008, and 0.03 mg/L, respectively. Linear calibration covered a biological exposure index (BEI) for urinary concentration. The within-run and total precisions (CV, %) were 5.6% and 9.2% for NMP, 3.4% and 4.2% for 5-HNMP, 3.7% and 6.0% for MSI, and 6.5% and 6.9% for 2-HMSI. The method was evaluated using international external quality assessment samples, and urine samples from workers exposed to NMP in an occupational area.

  17. Ionization chamber

    International Nuclear Information System (INIS)

    1977-01-01

    An improved ionization chamber type X-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is placed next to the anode and is maintained at a voltage intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting towards the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  18. Ionization detector

    International Nuclear Information System (INIS)

    Steele, D.S.

    1987-01-01

    An ionization detector having an array of detectors has, for example, grounding pads positioned in the spaces between some detectors (data detectors) and other detectors (reference detectors). The grounding pads are kept at zero electric potential, i.e. grounded. The grounding serves to drain away electrons and thereby prevent an unwanted accumulation of charge in the spaces, and cause the electric field lines to be more perpendicular to the detectors in regions near the grounding pads. Alternatively, no empty space is provided there being additional, grounded, detectors provided between the data and reference detectors. (author)

  19. Ionizing radiations

    International Nuclear Information System (INIS)

    2009-01-01

    After having recalled some fundamental notions and measurement units related to ionizing radiations, this document describes various aspects of natural and occupational exposures: exposure modes and sources, exposure levels, biological effects, health impacts. Then, it presents prevention principles aimed at, in an occupational context of use of radiation sources (nuclear industry excluded), reducing and managing these exposures: risk assessment, implementation of safety from the front end. Some practical cases illustrate the radiation protection approach. The legal and regulatory framework is presented: general notions, worker exposure, measures specific to some worker categories (pregnant and breast feeding women, young workers, temporary workers). A last part describes what is to be done in case of incident or accident (dissemination of radioactive substances from unsealed sources, anomaly occurring when using a generator or a sealed source, post-accident situation)

  20. Specificity enhancement by electrospray ionization multistage mass spectrometry--a valuable tool for differentiation and identification of 'V'-type chemical warfare agents.

    Science.gov (United States)

    Weissberg, Avi; Tzanani, Nitzan; Dagan, Shai

    2013-12-01

    The use of chemical warfare agents has become an issue of emerging concern. One of the challenges in analytical monitoring of the extremely toxic 'V'-type chemical weapons [O-alkyl S-(2-dialkylamino)ethyl alkylphosphonothiolates] is to distinguish and identify compounds of similar structure. MS analysis of these compounds reveals mostly fragment/product ions representing the amine-containing residue. Hence, isomers or derivatives with the same amine residue exhibit similar mass spectral patterns in both classical EI/MS and electrospray ionization-MS, leading to unavoidable ambiguity in the identification of the phosphonate moiety. A set of five 'V'-type agents, including O-ethyl S-(2-diisopropylamino)ethyl methylphosphonothiolate (VX), O-isobutyl S-(2-diethylamino)ethyl methylphosphonothiolate (RVX) and O-ethyl S-(2-diethylamino)ethyl methylphosphonothiolate (VM) were studied by liquid chromatography/electrospray ionization/MS, utilizing a QTRAP mass detector. MS/MS enhanced product ion scans and multistage MS(3) experiments were carried out. Based on the results, possible fragmentation pathways were proposed, and a method for the differentiation and identification of structural isomers and derivatives of 'V'-type chemical warfare agents was obtained. MS/MS enhanced product ion scans at various collision energies provided information-rich spectra, although many of the product ions obtained were at low abundance. Employing MS(3) experiments enhanced the selectivity for those low abundance product ions and provided spectra indicative of the different phosphonate groups. Study of the fragmentation pathways, revealing some less expected structures, was carried out and allowed the formulation of mechanistic rules and the determination of sets of ions typical of specific groups, for example, methylphosphonothiolates versus ethylphosphonothiolates. The new group-specific ions elucidated in this work are also useful for screening unknown 'V'-type agents and related

  1. Ring magnetron ionizer

    International Nuclear Information System (INIS)

    Alessi, J.G.

    1986-01-01

    A ring magnetron D - charge exchange ionizer has been built and tested. An H - current of 500 μA was extracted with an estimated H 0 density in the ionizer of 10 12 cm -3 . This exceeds the performance of ionizers presently in use on polarized H - sources. The ionizer will soon be tested with a polarized atomic beam

  2. Proteomic analysis of proteins expressing in regions of rat brain by a combination of SDS-PAGE with nano-liquid chromatography-quadrupole-time of flight tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Maekawa Tsuyoshi

    2010-07-01

    Full Text Available Abstract Background Most biological functions controlled by the brain and their related disorders are closely associated with activation in specific regions of the brain. Neuroproteomics has been applied to the analysis of whole brain, and the general pattern of protein expression in all regions has been elucidated. However, the comprehensive proteome of each brain region remains unclear. Results In this study, we carried out comparative proteomics of six regions of the adult rat brain: thalamus, hippocampus, frontal cortex, parietal cortex, occipital cortex, and amygdala using semi-quantitative analysis by Mascot Score of the identified proteins. In order to identify efficiently the proteins that are present in the brain, the proteins were separated by a combination of SDS-PAGE on a C18 column-equipped nano-liquid chromatograph, and analyzed by quadrupole-time of flight-tandem-mass spectrometry. The proteomic data show 2,909 peptides in the rat brain, with more than 200 identified as region-abundant proteins by semi-quantitative analysis. The regions containing the identified proteins are membrane (20.0%, cytoplasm (19.5%, mitochondrion (17.1%, cytoskeleton (8.2%, nucleus (4.7%, extracellular region (3.3%, and other (18.0%. Of the identified proteins, the expressions of glial fibrillary acidic protein, GABA transporter 3, Septin 5, heat shock protein 90, synaptotagmin, heat shock protein 70, and pyruvate kinase were confirmed by immunoblotting. We examined the distributions in rat brain of GABA transporter 3, glial fibrillary acidic protein, and heat shock protein 70 by immunohistochemistry, and found that the proteins are localized around the regions observed by proteomic analysis and immunoblotting. IPA analysis indicates that pathways closely related to the biological functions of each region may be activated in rat brain. Conclusions These observations indicate that proteomics in each region of adult rat brain may provide a novel way to

  3. Ionization of food products

    International Nuclear Information System (INIS)

    Vasseur, J.P.

    1991-01-01

    After general remarks on foods preservation, on international works and on ionization future prospects, main irradiation sources are described. Recalls on radioactivity, on radiation-matter interaction, on toxicology of ionized foods and on ionized foods detection are given. Ionization applications to various products are reviewed, especially in: - Poultry meat - Fishing products - Fresh fruits and vegetables - Dry fruits and vegetables - spices, tea, infusion - prepacked products... An evaluation of economics and sociocultural impacts is presented in connection with recent experiments [fr

  4. Foodstuffs preservation by ionization

    International Nuclear Information System (INIS)

    1991-12-01

    This document contains all the papers presented at the meeting on foodstuffs preservation by ionization. These papers deal especially with the food ionization process, its development and the view of the food industry on ionization. Refs and figs (F.M.)

  5. Online Simultaneous Hydrogen/Deuterium Exchange of Multitarget Gas-Phase Molecules by Electrospray Ionization Mass Spectrometry Coupled with Gas Chromatography.

    Science.gov (United States)

    Jeong, Eun Sook; Cha, Eunju; Cha, Sangwon; Kim, Sunghwan; Oh, Han Bin; Kwon, Oh-Seung; Lee, Jaeick

    2017-11-21

    In this study, a hydrogen/deuterium (H/D) exchange method using gas chromatography-electrospray ionization/mass spectrometry (GC-ESI/MS) was first investigated as a novel tool for online H/D exchange of multitarget analytes. The GC and ESI source were combined with a homemade heated column transfer line. GC-ESI/MS-based H/D exchange occurs in an atmospheric pressure ion source as a result of reacting the gas-phase analyte eluted from GC with charged droplets of deuterium oxide infused as the ESI spray solvent. The consumption of the deuterated solvent at a flow rate of 2 μL min -1 was more economical than that in online H/D exchange methods reported to date. In-ESI-source H/D exchange by GC-ESI/MS was applied to 11 stimulants with secondary amino or hydroxyl groups. After H/D exchange, the spectra of the stimulants showed unexchanged, partially exchanged, and fully exchanged ions showing various degrees of exchange. The relative abundances corrected for naturally occurring isotopes of the fully exchanged ions of stimulants, except for etamivan, were in the range 24.3-85.5%. Methylephedrine and cyclazodone showed low H/D exchange efficiency under acidic, neutral, and basic spray solvent conditions and nonexchange for etamivan with an acidic phenolic OH group. The in-ESI-source H/D exchange efficiency by GC-ESI/MS was sufficient to determine the number of hydrogen by elucidation of fragmentation from the spectrum. Therefore, this online H/D exchange technique using GC-ESI/MS has potential as an alternative method for simultaneous H/D exchange of multitarget analytes.

  6. Liquid chromatography/negative electrospray ionization ion trap MS(2) mass spectrometry application for the determination of microcystins occurrence in Southern Portugal water reservoirs.

    Science.gov (United States)

    Rodrigues, M A; Reis, M P; Mateus, M C

    2013-11-01

    Microcystins (MCs) are toxins produced by cyanobacteria which are common organisms in the phytoplankton of eutrophic lakes, rivers and freshwater reservoirs. In the present work, a novel method of liquid chromatography-electrospray ion trap tandem mass spectrometry (LC/ESI/Ion trap-MS/MS), operated in the negative ionization mode, was developed for the analysis of these cyanotoxins. The method was applied to determine the amounts of total microcystins-LR, -YR and -RR in two water reservoirs in Southern Portugal, namely Alqueva and Beliche. A total of 30 water samples were analysed along 2011. Solid phase extraction (SPE) was used for sample cleaning-up and analyte enrichment. The extracted toxins were separated on a C18 column with a gradient of acetonitrile/water with 0.1% formic acid. Detection of microcystins was carried out using multiple reaction monitoring (MRM) in the negative polarity mode, as this method gave a higher selectivity. The MC-RR, YR and LR quantification limits were 17.9, 31.7 and 15.8 ng/L, respectively; quite below the limits recommended by WHO guidelines for drinking water (1 μg/L). Total MC highest concentrations were found in the warm months of June, July and September in Alqueva sampling sites, with concentrations of MC LR and RR ranging 17-344 and 25-212 ng/L, respectively, showing comparable results for MC-RR and LR and slightly lower concentration of MC-YR. Detected values for Beliche reservoir were below quantification limits. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Tools to discover anionic and nonionic polyfluorinated alkyl surfactants by liquid chromatography electrospray ionisation mass spectrometry

    DEFF Research Database (Denmark)

    Trier, Xenia; Granby, Kit; Christensen, Jan H.

    2011-01-01

    peaks, belonging to homologues series with m/z of n×50Da (CF2) or n×100Da (CF2CF2). The elemental composition of the precursor ions were deducted from the accurate m/z values of the deprotonated molecules [M−H]−. In case of in-source fragmentation, the presence of dimers, e.g. [M2−H]− and adduct ions...

  8. High-performance liquid chromatography electrospray mass spectrometry as a method in proteomic research

    International Nuclear Information System (INIS)

    Walcher, W.

    2003-06-01

    During the sequencing of the human genome it became clear, that a lot of human diseases and/or malfunctions don't base on genomic information, but on differences at the protein level. Therefore biochemistry, biology and medicine are faced to various novel problems where new and authentic analysis methods are needed. Miniaturized chromatographic separation methods are frequently the methods of choice for the separation of peptides and proteins, when the amount of sample is limited. Monolithic capillary columns were prepared by copolymerization of styrene and divinylbenzene in the presence of a suitable porogen mixture of 1-decanol and tetrahydrofuran. The synthesized columns enabled the highly efficient separation of peptides and proteins by reversed-phase high-performance liquid chromatography (RP-HPLC) with peak capacities of 80 and more in 10 minutes. By the hyphenation of RP-HPLC to electrospray mass spectrometry (ESI-MS) the potential of the analysis method was even extended. The monolithic column technology was further miniaturized from 200 μm to 100 and 50 μm inner diameters to improve detection limits by RP-HPLC-ESI-MS. After the optimization of the RP-HPLC-ESI-MS method, the ion source and the ion transfer optics of an ion trap mass spectrometer (LCQ classic, Thermofinnigan) have been advanced for protein and peptide analysis. The improved RP-HPLC-ESI-MS system was subsequently applied to the detection of posttranslational protein modifications at the example of the nitration of bovine serum albumin (BSA). The results of the RP-HPLC-ESI-MS analysis were found to be highly reproducible, which enabled the determination of nitration degrees for different tyrosine residues in the protein sequence. Y 1 60, Y 4 96 and Y 3 52 or Y369 were found to be the predominant positions of protein nitration in BSA. At last light harvesting proteins from the photosystem II (PSII) of higher plants have been analyzed by RP-HPLC-ESI-MS and RP-HPLC-ESI-MSMS. Beside the affirmation of known protein masses a previously unknown protein isoform of PSII from spinach was found. A further characterization was achieved by a novel RP-HPLC-MS method, based on the kinetically controlled digestion of the protein and by subsequent MSMS peptide de-novo sequencing of the N-terminal protein sequence. (author)

  9. The effects of frozen tissue storage conditions on the integrity of RNA and protein.

    Science.gov (United States)

    Auer, H; Mobley, J A; Ayers, L W; Bowen, J; Chuaqui, R F; Johnson, L A; Livolsi, V A; Lubensky, I A; McGarvey, D; Monovich, L C; Moskaluk, C A; Rumpel, C A; Sexton, K C; Washington, M K; Wiles, K R; Grizzle, W E; Ramirez, N C

    2014-10-01

    Unfixed tissue specimens most frequently are stored for long term research uses at either -80° C or in vapor phase liquid nitrogen (VPLN). There is little information concerning the effects such long term storage on tissue RNA or protein available for extraction. Aliquots of 49 specimens were stored for 5-12 years at -80° C or in VPLN. Twelve additional paired specimens were stored for 1 year under identical conditions. RNA was isolated from all tissues and assessed for RNA yield, total RNA integrity and mRNA integrity. Protein stability was analyzed by surface-enhanced or matrix-assisted laser desorption ionization time of flight mass spectrometry (SELDI-TOF-MS, MALDI-TOF-MS) and nano-liquid chromatography electrospray ionization tandem mass spectrometry (nLC-ESI-MS/MS). RNA yield and total RNA integrity showed significantly better results for -80° C storage compared to VPLN storage; the transcripts that were preferentially degraded during VPLN storage were these involved in antigen presentation and processing. No consistent differences were found in the SELDI-TOF-MS, MALDI-TOF-MS or nLC-ESI-MS/MS analyses of specimens stored for more than 8 years at -80° C compared to those stored in VPLN. Long term storage of human research tissues at -80° C provides at least the same quality of RNA and protein as storage in VPLN.

  10. Revealing the glycation sites in synthetic neoglycoconjugates formed by conjugation of the antigenic monosaccharide hapten of Vibrio cholerae O1, serotype Ogawa with the BSA protein carrier using LC-ESI-QqTOF-MS/MS

    Science.gov (United States)

    Jahouh, Farid; Saksena, Rina; Kováč, Pavol; Banoub, Joseph

    2012-01-01

    In this manuscript, we present the determination of glycation sites in synthetic neoglycoconjugates formed by conjugation of the antigenic monosaccharide hapten of Vibrio cholerae O1 serotype Ogawa to BSA using nano- liquid chromatography electrospray ionization quadrupole time-of-flight tandem mass spectroscopy (LC-ESI-QqTOF-MS/MS). The matrix-assisted laser desorption/ionization-TOF/TOF-MS/MS analyses of the tryptic digests of the glycoconjugates having a hapten:BSA ratio of 4.3:1, 6.6:1 and 13.2:1 revealed only three glycation sites, on the following lysine residues: Lys 235, Lys 437 and Lys 455. Digestion of the neoglycoconjugates with the proteases trypsin and GluC V8 gave complementary structural information and was shown to maximize the number of recognized glycation sites. Here, we report identification of 20, 27 and 33 glycation sites using LC-ESI-QqTOF-MS/MS analysis of a series of synthetic neoglycoconjugates with a hapten:BSA ratio of, respectively, 4.3:1, 6.6:1 and 13.2:1. We also tentatively propose that all the glycated lysine residues are located mainly near the outer surface of the protein. PMID:22791257

  11. Ionizing radiation in environment

    International Nuclear Information System (INIS)

    Jandl, J.; Petr, I.

    1988-01-01

    The basic terms are explained such as the atom, radioactivity, nuclear reaction, interaction of ionizing radiation with matter, etc. The basic dosimetric variables and units and properties of radionuclides and ionizing radiation are given. Natural and artificial sources of ionizing radiation are discussed with regard to the environment and the propagation and migration of radionuclides is described in the environment to man. The impact is explained of ionizing radiation on the cell and the somatic and genetic effects of radiation on man are outlined. Attention is devoted to protection against ionizing radiation and to radiation limits, also to the detection, dosimetry and monitoring of ionizing radiation in the environment. (M.D.). 92 figs., 40 tabs. 74 refs

  12. Ionizing radiation in hospitals

    International Nuclear Information System (INIS)

    Blok, K.; Ginkel, G. van; Leun, K. van der; Muller, H.; Oude Elferink, J.; Vesseur, A.

    1985-10-01

    This booklet dels with the risks of the use of ionizing radiation for people working in a hospital. It is subdivided in three parts. Part 1 treats the properties of ionizing radiation in general. In part 2 the various applications are discussed of ionizing radiation in hospitals. Part 3 indicates how a not completely safe situation may be improved. (H.W.). 14 figs.; 4 tabs

  13. Dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Musilek, L.; Seda, J.; Trousil, J.

    1992-01-01

    The publication deals with a major field of ionizing radiation dosimetry, viz., integrating dosimetric methods, which are the basic means of operative dose determination. It is divided into the following sections: physical and chemical effects of ionizing radiation; integrating dosimetric methods for low radiation doses (film dosimetry, nuclear emulsions, thermoluminescence, radiophotoluminescence, solid-state track detectors, integrating ionization dosemeters); dosimetry of high ionizing radiation doses (chemical dosimetric methods, dosemeters based on the coloring effect, activation detectors); additional methods applicable to integrating dosimetry (exoelectron emission, electron spin resonance, lyoluminescence, etc.); and calibration techniques for dosimetric instrumentation. (Z.S.). 422 refs

  14. Improvements in ionization chambers

    International Nuclear Information System (INIS)

    Whetten, N.R.; Zubal, C.

    1980-01-01

    A method of reducing mechanical vibrations transmitted to the parallel plate electrodes of ionization chamber x-ray detectors, commonly used in computerized x-ray axial tomography systems, is described. The metal plate cathodes and anodes are mounted in the ionizable gas on dielectric sheet insulators consisting of a composite of silicone resin and glass fibres. (UK)

  15. Dual ionization chamber

    International Nuclear Information System (INIS)

    Mallory, J.; Turlej, Z.

    1981-01-01

    Dual ionization chambers are provided for use with an electronic smoke detector. The chambers are separated by electrically-conductive partition. A single radiation source extends through the partition into both chambers, ionizing the air in each. The mid-point current of the device may be balanced by adjusting the position of the source

  16. Introduction to ionizing radiation physics

    International Nuclear Information System (INIS)

    Musilek, L.

    1979-01-01

    Basic properties are described of the atom, atomic nucleus and of ionizing radiation particles; nuclear reactions, ionizing radiation sources and ionizing radiation interaction with matter are explained. (J.P.)

  17. Biological Effects of Ionizing Radiation

    Science.gov (United States)

    Ingram, M.; Mason, W. B.; Whipple, G. H.; Howland, J. W.

    1952-04-07

    This report presents a review of present knowledge and concepts of the biological effects of ionizing radiations. Among the topics discussed are the physical and chemical effects of ionizing radiation on biological systems, morphological and physiological changes observed in biological systems subjected to ionizing radiations, physiological changes in the intact animal, latent changes following exposure of biological systems to ionizing radiations, factors influencing the biological response to ionizing radiation, relative effects of various ionizing radiations, and biological dosimetry.

  18. Simultaneous determination of phentermine and topiramate in human plasma by liquid chromatography-tandem mass spectrometry with positive/negative ion-switching electrospray ionization and its application in pharmacokinetic study.

    Science.gov (United States)

    Ni, Yang; Zhou, Ying; Xu, Mingzhen; He, Xiaomeng; Li, Huqun; Haseeb, Satter; Chen, Hui; Li, Weiyong

    2015-03-25

    A new method for simultaneous determination of phentermine and topiramate by liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) operated in positive and negative ionization switching modes was developed and validated. Protein precipitation with acetonitrile was selected for sample preparation. Analyses were performed on a liquid chromatography system employing a Kromasil 60-5CN column (2.1 mm × 100 mm, 5 μm) and an isocratic elution with mixed solution of acetonitrile-20mM ammonium formate containing 0.3% formic acid (40:60, v/v), at a flow rate of 0.35 mL/min. Doxazosin mesylate and pioglitazone were used as the internal standard (IS) respectively for quantification. The determination was carried out on an API 4000 triple-quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using the following transitions monitored simultaneously: positive m/z 150.0/91.0 for phentermine, m/z 452.1/344.3 for doxazosin, and negative m/z 338.3/77.9 for topiramate, m/z 355.0/41.9 for pioglitazone. The method was validated to be linear over the concentration range of 1-800 ng mL(-1) for phentermine, 1-1000 ng mL(-1) for topiramate. Within- and between-day accuracy and precision of the validated method at three different concentration levels were within the acceptable limits of <15% at all concentrations. Blood samples were collected into heparinized tubes before and after administration. The simple and robust LC/MS/MS method was successfully applied for the simultaneous determination of phentermine and topiramate in a pharmacokinetic study in healthy male Chinese volunteers. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Miniature ionization chamber

    International Nuclear Information System (INIS)

    Alexeev, V.I.; Emelyanov, I.Y.; Ivanov, V.M.; Konstantinov, L.V.; Lysikov, B.V.; Postnikov, V.V.; Rybakov, J.V.

    1976-01-01

    A miniature ionization chamber having a gas-filled housing which accommodates a guard electrode made in the form of a hollow perforated cylinder is described. The cylinder is electrically associated with the intermediate coaxial conductor of a triaxial cable used as the lead-in of the ionization chamber. The gas-filled housing of the ionization chamber also accommodates a collecting electrode shaped as a rod electrically connected to the center conductor of the cable and to tubular members. The rod is disposed internally of the guard electrode and is electrically connected, by means of jumpers passing through the holes in the guard electrode, to the tubular members. The tubular members embrace the guard electrode and are spaced a certain distance apart along its entire length. Arranged intermediate of these tubular members are spacers secured to the guard electrode and fixing the collecting electrode throughout its length with respect to the housing of the ionization chamber

  20. What is ''ionizing radiation''?

    International Nuclear Information System (INIS)

    Tschurlovits, M.

    1997-01-01

    The scientific background of radiation protection and hence ''ionizing radiation'' is undergoing substantial regress since a century. Radiations as we are concerned with are from the beginning defined based upon their effects rather than upon the physical origin and their properties. This might be one of the reasons why the definition of the term ''ionizing radiation'' in radiation protection is still weak from an up to date point of view in texts as well as in international and national standards. The general meaning is unambiguous, but a numerical value depends on a number of conditions and the purpose. Hence, a clear statement on a numerical value of the energy threshold beyond a radiation has to be considered as ''ionizing'' is still missing. The existing definitions are, therefore, either correct but very general or theoretical and hence not applicable. This paper reviews existing definitions and suggests some issues to be taken into account for possible improvement of the definition of ''ionizing radiation''. (author)

  1. 'Saddle-point' ionization

    International Nuclear Information System (INIS)

    Gay, T.J.; Hale, E.B.; Irby, V.D.; Olson, R.E.; Missouri Univ., Rolla; Berry, H.G.

    1988-01-01

    We have studied the ionization of rare gases by protons at intermediate energies, i.e., energies at which the velocities of the proton and the target-gas valence electrons are comparable. A significant channel for electron production in the forward direction is shown to be 'saddle-point' ionization, in which electrons are stranded on or near the saddle-point of electric potential between the receding projectile and the ionized target. Such electrons yield characteristic energy spectra, and contribute significantly to forward-electron-production cross sections. Classical trajectory Monte Carlo calculations are found to provide qualitative agreement with our measurements and the earlier measurements of Rudd and coworkers, and reproduce, in detail, the features of the general ionization spectra. (orig.)

  2. Ionization particle detector

    International Nuclear Information System (INIS)

    Ried, L.

    1982-01-01

    A new device is claimed for detecting particles in a gas. The invention comprises a low cost, easy to assemble, and highly accurate particle detector using a single ionization chamber to contain a reference region and a sensing region. The chamber is designed with the radioactive source near one electrode and the second electrode located at a distance less than the distance of maximum ionization from the radioactive source

  3. The critical ionization velocity

    International Nuclear Information System (INIS)

    Raadu, M.A.

    1980-06-01

    The critical ionization velocity effect was first proposed in the context of space plasmas. This effect occurs for a neutral gas moving through a magnetized plasma and leads to rapid ionization and braking of the relative motion when a marginal velocity, 'the critical velocity', is exceeded. Laboratory experiments have clearly established the significance of the critical velocity and have provided evidence for an underlying mechanism which relies on the combined action of electron impact ionization and a collective plasma interaction heating electrons. There is experimental support for such a mechanism based on the heating of electrons by the modified two-stream instability as part of a feedback process. Several applications to space plasmas have been proposed and the possibility of space experiments has been discussed. (author)

  4. Ionization front accelerator

    International Nuclear Information System (INIS)

    Olson, C.L.

    1975-01-01

    In a recently proposed linear collective accelerator, ions are accelerated in a steep, moving potential well created at the head of an intense relativistic electron beam. The steepness of the potential well and its motion are controlled by the external ionization of a suitable background gas. Calculations concerning optimum choices for the background gas and the ionization method are presented; a two-step photoionization process employing Cs vapor is proposed. In this process, a super-radiant light source is used to excite the gas, and a UV laser is used to photoionize the excited state. The appropriate line widths and coupled ionization growth rate equations are discussed. Parameter estimates are given for a feasibility experiment, for a 1 GeV proton accelerator, and for a heavy ion accelerator (50 MeV/nucleon uranium). (auth)

  5. The ionizing treatment of food

    International Nuclear Information System (INIS)

    1998-01-01

    This book of proceedings contains the talks given by the members of the Society of chemical experts of France (SECF) and by various specialists of the ionizing treatment during the scientific days of September 25-26, 1997. The aim of this meeting was to reconsider the effects of ionization from a scientific point of view and apart from the polemics generated by this domain. The following topics were discussed successively: source and characterization of a ionizing treatment, biological effects of ionization on food and the expected consequences, the ionizing treatment and the reduction of the vitamin C content of fruits and vegetables, is it safe to eat irradiated food?, the organoleptic modifications of food after ionization, quality assurance of dosimetry measurements in an industrial installation of food ionization, the French and European regulations in food ionization, the detection of irradiated foodstuffs, processed food and complex lipid matrices, sterilization of dishes for immuno-depressed patients using ionization. (J.S.)

  6. Ambient ionization mass spectrometry

    International Nuclear Information System (INIS)

    Lebedev, A T

    2015-01-01

    Ambient ionization mass spectrometry emerged as a new scientific discipline only about ten years ago. A considerable body of information has been reported since that time. Keeping the sensitivity, performance and informativity of classical mass spectrometry methods, the new approach made it possible to eliminate laborious sample preparation procedures and triggered the development of miniaturized instruments to work directly in the field. The review concerns the theoretical foundations and design of ambient ionization methods. Their advantages and drawbacks, as well as prospects for application in chemistry, biology, medicine, environmetal analysis, etc., are discussed. The bibliography includes 194 references

  7. Liquid ionizing radiaion detector

    International Nuclear Information System (INIS)

    deGaston, A.N.

    1979-01-01

    A normally nonconducting liquid such as liquid hydrocarbon is encased between a pair of electrodes in an enclosure so that when the liquid is subjected to ionizing radiation, the ion pairs so created measurably increase the conductivity of the fluid. The reduced impedance between the electrodes is detectable with a sensitive ohm-meter and indicates the amount of ionizing radiation. The enclosure, the electrodes and the fluid can be constructed of materials that make the response of the detector suitable for calibrating a large range of radiation energy levels. The detector is especially useful in medical applications where tissue equivalent X ray detectors are desired

  8. Radiation dependent ionization model

    International Nuclear Information System (INIS)

    Busquet, M.

    1991-01-01

    For laser created plasma simulation, hydrodynamics codes need a non-LTE atomic physics package for both EOS and optical properties (emissivity and opacity). However in XRL targets as in some ICF targets, high Z material can be found. In these cases radiation trapping can induce a significant departure from the optically thin ionization description. The authors present a method to change an existing LTE code into a non-LTE code with coupling of ionization to radiation. This method has very low CPU cost and can be used in 2D simulations

  9. Ionizing Radiation Processing Technology

    International Nuclear Information System (INIS)

    Rida Tajau; Kamarudin Hashim; Jamaliah Sharif; Ratnam, C.T.; Keong, C.C.

    2017-01-01

    This book completely brief on the basic concept and theory of ionizing radiation in polymers material processing. Besides of that the basic concept of polymerization addition, cross-linking and radiation degradation also highlighted in this informative book. All of the information is from scientific writing based on comprehensive scientific research in polymerization industry which using the radiation ionizing. It is very useful to other researcher whose study in Nuclear Sciencea and Science of Chemical and Material to use this book as a guideline for them in future scientific esearch.

  10. Contact ionization ion source

    International Nuclear Information System (INIS)

    Hashmi, N.; Van Der Houven Van Oordt, A.J.

    1975-01-01

    An ion source in which an apertured or foraminous electrode having a multiplicity of openings is spaced from one or more active surfaces of an ionisation electrode, the active surfaces comprising a material capable of ionising by contact ionization a substance to be ionized supplied during operation to the active surface or surfaces comprises means for producing during operation a magnetic field which enables a stable plasma to be formed in the space between the active surface or surfaces and the apertured electrode, the field strength of the magnetic field being preferably in the range between 2 and 8 kilogauss. (U.S.)

  11. Detection of ionized foods

    International Nuclear Information System (INIS)

    Beerens, H.

    1986-01-01

    Irradiated foods and feed might be identified with two kinds of tests: 1. biochemical: detection of specific products are not yet available 2. microbiological: when a microbial species dissapears from a sample of food i.e. it is not detectable after enrichment (for instance Coliforms in hamburgers) it is likely that the sample has been ionized [fr

  12. Ionization loss in BGO

    International Nuclear Information System (INIS)

    Bakken, J.A.; Denes, P.; Piroue, P.A.; Stickland, D.P.; Sumner, R.L.; Taylor, C.; Barone, L.; Borgia, B.; Diemoz, M.; Dionisi, C.; Falciano, S.; Ferroni, F.; Gratta, G.; Longo, E.; Luminari, L.; Morganti, S.; Valente, E.; Blaising, J.J.; Boutigny, D.; Coignet, G.; Karyotakis, Y.; Sauvage, G.; Schneegans, M.; Vivargent, M.; Extermann, P.; Morand, G.; Ossmann, J.; Ruckstuhl, W.; Schaad, T.P.; Lecoq, P.; Walk, W.; Li, P.J.; Micke, M.; Micke, U.; Schmitz, D.

    1988-01-01

    We report on a precise measurement of the energy loss through ionization by pions in bismuth germanate performed at several values of the incident particles momentum with a prototype of the L3 electromagnetic calorimeter. The experimental results are in good agreement with theoretical predictions showing the relativistic rise modified by density effect. (orig.)

  13. Ionizing radiation from tobacco

    International Nuclear Information System (INIS)

    Westin, J.B.

    1987-01-01

    Accidents at nuclear power facilities seem inevitably to bring in their wake a great deal of concern on the part of both the lay and medical communities. Relatively little attention, however, is given to what may be the largest single worldwide source of effectively carcinogenic ionizing radiation: tobacco. The risk of cancer deaths from the Chernobyl disaster are tobacco smoke is discussed

  14. Ionization beam scanner

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Inner structure of an ionization beam scanner, a rather intricate piece of apparatus which permits one to measure the density distribution of the proton beam passing through it. On the outside of the tank wall there is the coil for the longitudinal magnetic field, on the inside, one can see the arrangement of electrodes creating a highly homogeneous transverse electric field.

  15. Basic ionizing radiation symbol

    International Nuclear Information System (INIS)

    1987-01-01

    A description is given of the standard symbol for ionizing radiation and of the conditions under which it should not be used. The Arabic equivalent of some English technical terms in this subject is given in one page. 1 ref., 1 fig

  16. Ionizing radiation and life.

    Science.gov (United States)

    Dartnell, Lewis R

    2011-01-01

    Ionizing radiation is a ubiquitous feature of the Cosmos, from exogenous cosmic rays (CR) to the intrinsic mineral radioactivity of a habitable world, and its influences on the emergence and persistence of life are wide-ranging and profound. Much attention has already been focused on the deleterious effects of ionizing radiation on organisms and the complex molecules of life, but ionizing radiation also performs many crucial functions in the generation of habitable planetary environments and the origins of life. This review surveys the role of CR and mineral radioactivity in star formation, generation of biogenic elements, and the synthesis of organic molecules and driving of prebiotic chemistry. Another major theme is the multiple layers of shielding of planetary surfaces from the flux of cosmic radiation and the various effects on a biosphere of violent but rare astrophysical events such as supernovae and gamma-ray bursts. The influences of CR can also be duplicitous, such as limiting the survival of surface life on Mars while potentially supporting a subsurface biosphere in the ocean of Europa. This review highlights the common thread that ionizing radiation forms between the disparate component disciplines of astrobiology. © Mary Ann Liebert, Inc.

  17. Ionization chamber smoke detectors

    International Nuclear Information System (INIS)

    1988-03-01

    One kind of smoke detector, the ionization-type, is regulated by the Atomic Energy Control Board (AECB) because it uses a radioactive substance in its mechanism. Radioactivity and radiation are natural phenomena, but they are not very familiar to the average householder. This has led to a number of questions being asked of the AECB. These questions and AECB responses are outlined

  18. Ionization of Interstellar Hydrogen

    Science.gov (United States)

    Whang, Y. C.

    1996-09-01

    Interstellar hydrogen can penetrate through the heliopause, enter the heliosphere, and may become ionized by photoionization and by charge exchange with solar wind protons. A fluid model is introduced to study the flow of interstellar hydrogen in the heliosphere. The flow is governed by moment equations obtained from integration of the Boltzmann equation over the velocity space. Under the assumption that the flow is steady axisymmetric and the pressure is isotropic, we develop a method of solution for this fluid model. This model and the method of solution can be used to study the flow of neutral hydrogen with various forms of ionization rate β and boundary conditions for the flow on the upwind side. We study the solution of a special case in which the ionization rate β is inversely proportional to R2 and the interstellar hydrogen flow is uniform at infinity on the upwind side. We solve the moment equations directly for the normalized density NH/NN∞, bulk velocity VH/VN∞, and temperature TH/TN∞ of interstellar hydrogen as functions of r/λ and z/λ, where λ is the ionization scale length. The solution is compared with the kinetic theory solution of Lallement et al. The fluid solution is much less time-consuming than the kinetic theory solutions. Since the ionization rate for production of pickup protons is directly proportional to the local density of neutral hydrogen, the high-resolution solution of interstellar neutral hydrogen obtained here will be used to study the global distribution of pickup protons.

  19. Equipment for handling ionization chamber

    International Nuclear Information System (INIS)

    Altmann, J.

    1988-01-01

    The device consists of an ionization channel with an ionization chamber, of a support ring, axial and radial bearings, a sleeve, a screw gear and an electric motor. The ionization chamber is freely placed on the bottom of the ionization channel. The bottom part of the channel deviates from the vertical axis. The support ring propped against the axial bearing in the sleeve is firmly fixed to the top part of the ionization channel. The sleeve is fixed to the reactor lid. Its bottom part is provided with a recess for the radial bearing which is propped against a screw wheel firmly connected to the ionization channel. In measuring neutron flux, the screw wheel is rotated by the motor, thus rotating the whole ionization channel such that the ionization chamber is displaced into the reactor core.(J.B.). 1 fig

  20. Epidemiology and ionizing radiations

    International Nuclear Information System (INIS)

    Bourguignon, M.; Masse, R.; Slama, R.; Spira, A.; Timarche, M.; Laurier, D.; Billon, S.; Rogel, A.; Telle Lamberton, M.; Catelinois, O.; Thierry, I.; Grosche, B.; Ron, E.; Vathaire, F. de; Cherie Challine, L.; Donadieu, J.; Pirard, Ph.; Bloch, J.; Setbon, M.

    2004-01-01

    The ionizing radiations have effects on living being. The determinist effects appear since a threshold of absorbed dose of radiation is reached. In return, the stochastic effects of ionizing radiations are these ones whom apparition cannot be described except in terms of probabilities. They are in one hand, cancers and leukemia, on the other hand, lesions of the genome potentially transmissible to the descendants. That is why epidemiology, defined by specialists as the science that studies the frequency and distribution of illness in time and space, the contribution of factors that determine this frequency and this distribution among human populations. This issue gathers and synthesizes the knowledge and examines the difficulties of methodologies. It allows to give its true place to epidemiology. (N.C.)

  1. Gridded ionization chamber

    International Nuclear Information System (INIS)

    Houston, J.M.

    1977-01-01

    An improved ionization chamber type x-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is disposed adjacent the anode and is maintained at a voltsge intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting toward the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  2. Sensor for ionizable elements

    International Nuclear Information System (INIS)

    Berkey, E.; Reed, W.A. III; Hickam, W.M.

    1977-01-01

    Sensor to detect thermally ionizable elements or molucules in air, water vapour or oxygen or to be used as alkali leak detector in vacuum systems, e.g. in the pipe system of a liquid-metal cooled FBR. The sensor consists of an filament made of thorium-containing iridium as cathode with a temperature upto 1000 0 C and an anode sheet of molybdenum, nickel or stainless steal. (ORU) [de

  3. Gridded Ionization Chamber

    International Nuclear Information System (INIS)

    Manero Amoros, F.

    1962-01-01

    In the present paper the working principles of a gridded ionization chamber are given, and all the different factors that determine its resolution power are analyzed in detail. One of these devices, built in the Physics Division of the JEN and designed specially for use in measurements of alpha spectroscopy, is described. finally the main applications, in which the chamber can be used, are shown. (Author) 17 refs

  4. Pregnancy and ionizing radiation

    International Nuclear Information System (INIS)

    Plataniotis, Th.N.; Nikolaou, K.I.; Syrgiamiotis, G.V.; Dousi, M.; Panou, Th.; Georgiadis, K.; Bougias, C.

    2008-01-01

    Full text: In this report there will be presented the effects of ionizing radiation at the fetus and the necessary radioprotection. The biological results on the fetus, caused by the irradiation, depend on the dose of ionizing radiation that it receives and the phase of its evolution. The imminent effects of the irradiation can cause the fetus death, abnormalities and mental retardation, which are the result of overdose. The effects are carcinogenesis and leukemia, which are relative to the acceptable irradiating dose at the fetus and accounts about 0,015 % per 1 mSv. The effects of ionizing radiation depend on the phase of the fetus evolution: 1 st phase (1 st - 2 nd week): presence of low danger; 2 nd phase (3 rd - 8 th week): for doses >100 mSv there is the possibility of dysplasia; 3 rd phase (8 th week - birth): this phase concerns the results with a percentage 0,015 % per 1 mSv. We always must follow some rules of radioprotection and especially at Classical radiation use of necessary protocols (low dose), at Nuclear Medicine use of the right radioisotope and the relative field of irradiation for the protection of the adjacent healthy tissues and at Radiotherapy extreme caution is required regarding the dose and the treatment. In any case, it is forbidden to end a pregnancy when the pregnant undergoes medical exams, in which the uterus is in the beam of irradiation. The radiographer must always discuss the possibility of pregnancy. (author)

  5. Non-ionizing radiation

    International Nuclear Information System (INIS)

    Fischer, P.G.

    1983-01-01

    The still growing use of non-ionizing radiation such as ultraviolet radiation laser light, ultrasound and infrasound, has induced growing interest in the effects of these types of radiation on the human organism, and in probable hazards emanating from their application. As there are up to now no generally approved regulations or standards governing the use of non-ionizing radiation and the prevention of damage, it is up to the manufacturers of the relevant equipment to provide for safety in the use of their apparatus. This situation has led to a feeling of incertainty among manufacturers, as to how which kind of damage should be avoided. Practice has shown that there is a demand for guidelines stating limiting values, for measuring techniques clearly indicating safety thresholds, and for safety rules providing for safe handling. The task group 'Non-ionizing radiation' of the Radiation Protection Association started a programme to fulfill this task. Experts interested in this work have been invited to exchange their knowledge and experience in this field, and a collection of loose leaves will soon be published giving information and recommendations. (orig./HP) [de

  6. Ionization of anisothermal plasmas

    International Nuclear Information System (INIS)

    Dennery, F.M.

    1994-01-01

    During this last mid-century, only the temperature of electrons has been involved in the Saha's mass action law, whatever be the other ionic and neutral ones in any isothermal or anisothermal plasma. In order to set aside this underlying paradox in the case of argon ionization, it is necessary to improve this equation of partial equilibrium after having defined: - the basic Gibbs-Duhem's relations for such a polythermal mixture, - the inhomogeneous equilibrium issued from chemical reactions according to Le Chatelier's principle. (author). 3 refs

  7. Ionization detectors, ch. 3

    International Nuclear Information System (INIS)

    Sevcik, J.

    1976-01-01

    Most measuring devices used in gas chromatography consist of detectors that measure the ionization current. The process is based on the collision of a moving high-energy particle with a target particle that is ionised while an electron is freed. The discussion of the conditions of the collision reaction, the properties of the colliding particles, and the intensity of the applied field point to a unified classification of ionisation detectors. Radioactive sources suitable for use in these detectors are surveyed. The slow-down mechanism, recombination and background current effect are discussed

  8. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1982-01-01

    An ionization smoke detector employs a single radiation source in a construction comprising at least two chambers with a center or node electrode. The radioactive source is associated with this central electrode, and its positioning may be adjusted relative to the electrode to alter the proportion of the source that protrudes into each chamber. The source may also be mounted in the plane of the central electrode, and positioned relative to the center of the electrode. The central electrode or source may be made tiltable relative to the body of the detector

  9. Personnel ionizing radiation dosimeter

    International Nuclear Information System (INIS)

    Williams, R.A.

    1975-01-01

    A dosimeter and method for use by personnel working in an area of mixed ionizing radiation fields for measuring and/or determining the effective energy of x- and gamma radiation; beta, x-, and gamma radiation dose equivalent to the surface of the body; beta, x-, and gamma radiation dose equivalent at a depth in the body; the presence of slow neutron, fast neutron dose equivalent; and orientation of the person wearing the dosimeter to the source of radiation is disclosed. Optionally integrated into this device and method are improved means for determining neutron energy spectrum and absorbed dose from fission gamma and neutron radiation resulting from accidental criticality

  10. Doubly resonant multiphoton ionization

    International Nuclear Information System (INIS)

    Crance, M.

    1978-01-01

    A particular case of doubly resonant multiphoton ionization is theoretically investigated. More precisely, two levels quasi-resonant with two successive harmonics of the field frequency are considered. The method used is based on the effective operator formalism first introduced for this problem by Armstrong, Beers and Feneuille. The main result is to show the possibility of observing large interference effects on the width of the resonances. Moreover this treatment allows us to make more precise the connection between effective operator formalism and standard perturbation theory

  11. Plasma production via field ionization

    Directory of Open Access Journals (Sweden)

    C. L. O’Connell

    2006-10-01

    Full Text Available Plasma production via field ionization occurs when an incoming particle beam is sufficiently dense that the electric field associated with the beam ionizes a neutral vapor or gas. Experiments conducted at the Stanford Linear Accelerator Center explore the threshold conditions necessary to induce field ionization by an electron beam in a neutral lithium vapor. By independently varying the transverse beam size, number of electrons per bunch, or bunch length, the radial component of the electric field is controlled to be above or below the threshold for field ionization. Additional experiments ionized neutral xenon and neutral nitric oxide by varying the incoming beam’s bunch length. A self-ionized plasma is an essential step for the viability of plasma-based accelerators for future high-energy experiments.

  12. Biology of ionizing radiation effects

    International Nuclear Information System (INIS)

    Ferradini, C.; Pucheault, J.

    1983-01-01

    The present trends in biology of ionizing radiation are reviewed. The following topics are investigated: interaction of ionizing radiations with matter; the radiolysis of water and aqueous solutions; properties of the free radicals intervening in the couples O 2 /H 2 O and H 2 O/H 2 ; radiation chemistry of biological compounds; biological effects of ionizing radiations; biochemical mechanisms involving free radicals as intermediates; applications (biotechnological applications, origins of life) [fr

  13. News about ionized food identification

    International Nuclear Information System (INIS)

    Raffi, J.

    1995-01-01

    The ionizing radiations are used to clean food and increase their preservation life. If a lot of countries permits ionized products commercialization, others are opposed to it. To control the commercial exchanges, check the applied treatment aim and give to the consumers a better information, several ionized food identification methods were perfected and several are about to be recognized as european standards. 4 refs. 3 figs, 1 tab

  14. Resonance ionization spectroscopy 1990

    International Nuclear Information System (INIS)

    Parks, J.E.; Omenetto, N.

    1991-01-01

    The Fifth International Symposium on Resonance Ionization Spectroscopy (RIS) and its Applications was held in Varese, Italy, 16-21 September 1990. Interest in RIS and its applications continues to grow, and RIS is expanding into a more diverse and mature field of study. This maturity was evident in this meeting both in the basic science and understanding of RIS processes and in the number of new and improved applications and techniques. The application of RIS techniques to molecular detection problems made remarkable progress since the last meeting two years ago. Subtle effects pertaining to isotopic discrimination received more theoretical attention, and there now seems to be good understanding of these effects, which can lead to correction procedures and/or methods to avoid isotopic effects. RIS applications were presented in which significant, real world problems were addressed, demonstrating its capability to solve problems that previously could not be accurately solved by other more traditional techniques. The contributions to the conference are grouped under the following major topic headings: physics applications of rare atoms; laser ionization mechanisms - spectroscopy; atomic, molecular and ion sources; molecular RIS; atomic RIS - Rydberg states; environmental trace analysis; biological and medical applications; state selected chemistry; new laser sources and techniques; ultra-high resolution and isotopic selectivity; surface and bulk analysis. (Author)

  15. Hygiene of ionizing radiations

    International Nuclear Information System (INIS)

    Legare, I.-M.; Conceicao Cunha, M. da

    1976-01-01

    The concepts of quality factor and rem are introduced and a table of biological effects of external ionizing radiation sources is presented. Natural exposures, with tables of background radiation sources and of doses due to cosmic rays on high altitude areas and their populations are treated, as well as medical exposures; artificial background; fallout; scientific, industrial and other sources. The maximum and limit doses for man are given and tables of maximum admissible doses of ionizing radiations for 16-18 year old workers professionaly exposed, for professionals eventually subjected to radiation in their work and for people eventually exposed. Professional protection is discussed and tables are given of half-value layer of water, concrete, iron and lead for radiations of different energies, as well as the classification of exposure zones to the radiations and of maximum acceptable contamination for surfaces. The basic safety standards for radiation protection are summarized; tables are given also with emergency references for internal irradiation. Procedures with patients which received radioisotopes are discussed. At last, consideration is given to the problem of radioactive wastes in connection with the medical use of radionuclides [pt

  16. Foundations of ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Denisenko, O.N.; Pereslegin, I.A.

    1985-01-01

    Foundations of dosimetry in application to radiotherapy are presented. General characteristics of ionizing radiations and main characteristics of ionizing radiation sources, mostly used in radiotherapy, are given. Values and units for measuring ionizing radiation (activity of a radioactive substance, absorbed dose, exposure dose, integral dose and dose equivalent are considered. Different methods and instruments for ionizing radiation dosimetry are discussed. The attention is paid to the foundations of clinical dosimetry (representation of anatomo-topographic information, choice of radiation conditions, realization of radiation methods, corrections for a configuration and inhomogeneity of a patient's body, account of biological factors of radiation effects, instruments of dose field formation, control of irradiation procedure chosen)

  17. [Ionizing and non-ionizing radiation (comparative risk estimations)].

    Science.gov (United States)

    Grigor'ev, Iu G

    2012-01-01

    The population has widely used mobile communication for already more than 15 years. It is important to note that the use of mobile communication has sharply changed the conditions of daily exposure of the population to EME We expose our brain daily for the first time in the entire civilization. The mobile phone is an open and uncontrollable source of electromagnetic radiation. The comparative risk estimation for the population of ionizing and non-ionizing radiation was carried out taking into account the real conditions of influence. Comparison of risks for the population of ionizing and non-ionizing radiation leads us to a conclusion that EMF RF exposure in conditions of wide use of mobile communication is potentially more harmful than ionizing radiation influence.

  18. Fragment profiling of low molecular weight heparins using reversed phase ion pair liquid chromatography-electrospray mass spectrometry.

    Science.gov (United States)

    Xu, Xiaohui; Li, Daoyuan; Chi, Lequan; Du, Xuzhao; Bai, Xue; Chi, Lianli

    2015-04-30

    Low molecular weight heparins (LMWHs) are linear and highly charged carbohydrate polymers prepared by chemical or enzymatic depolymerization of heparin. Compared to unfractionated heparin (UFH), LMWHs are prevalently used as clinical anticoagulant drugs due to their lower side effects and better bioavailability. The work presented herein provides a rapid and powerful fragment mapping method for structural characterization of LMWHs. The chain fragments of two types of LMWHs, enoxaparin and nadroparin, were generated by controlled enzymatic digestion with each of heparinase I (Hep I, Enzyme Commission (EC) # 4.2.2.7), heparinase II (Hep II, no EC # assigned) and heparinase III (Hep III, EC # 4.2.2.8). Reversed phase ion pair high performance liquid chromatography (RPIP-HPLC) coupled with electrospray ion trap time-of-flight mass spectrometry (ESI-IT-TOF-MS) was used to profile the oligosaccharide chains ranging from disaccharides to decasaccharides. A database containing all theoretical structural compositions was established to assist the mass spectra interpretation. The six digests derived by three enzymes from two types of LMWHs exhibited distinguishable fingerprinting patterns. And a total of 94 enoxaparin fragments and 109 nadroparin fragments were detected and identified. Besides the common LMWH oligosaccharides, many components containing characteristic LMWH structures such as saturated L-idopyranosuronic acid, 2,5-anhydro-D-mannitol, 1,6-anhydro-D-aminopyranose, as well as odd number oligosaccharides were also revealed. Quantitative comparison of major components derived from innovator and generic nadroparin products was presented. This approach to profile LMWHs' fragments offers a highly reproducible, high resolution and information-rich tool for evaluating the quality of this category of anticoagulant drugs or comparing structural similarities among samples from various sources. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Enhanced detection of amino acids in hydrophilic interaction chromatography electrospray tandem mass spectrometry with carboxylic acids as mobile phase additives.

    Science.gov (United States)

    Yin, Dengyang; Hu, Xunxiu; Liu, Dantong; Du, Wencheng; Wang, Haibo; Guo, Mengzhe; Tang, Daoquan

    2017-06-01

    Liquid chromatography coupled with mass spectrometry technique has been widely used in the analysis of biological targets such as amino acids, peptides, and proteins. In this work, eight common single carboxylic acids or diacids, which contain different pKa have been investigated as the additives to the analysis of amino acids. As the results, carboxylic acid additive can improve the signal intensity of acidity amino acids such as Asp and Glu and the chromatographic separation of basic amino acids such as Arg, His, and Lys. In particular, the diacids have better performance than single acids. The proposed mechanism is that the diacid has hydrogen bond interaction with amino acids to reduce their polarity/amphiprotic characteristics. Besides, oxalic acid has been found having better enhancement than phthalic acid by overall consideration. Therefore, we successfully quantified the 15 amino acids in Sepia bulk pharmaceutical chemical by using oxalic acid as the additive.

  20. [Analysis of saponins from panax notoginseng using pressurized solvent extraction coupled with liquid chromatography-electrospray mass spectrum].

    Science.gov (United States)

    Wan, Jianbo; Li, Changming; Li, Shaopin; Kong, Lingyi; Wang, Yitao

    2005-10-01

    To establish a method for qualitative analysis of saponins from Panax notoginseng using pressurized solvent extraction coupled with LC-ESI-MS. The PSE technology was applied to the process of extraction for Panax notoginseng, and the negative ion detection and multiple reaction monitoring model were used. The saponins were investigated based on total ion chromatogram (TIC) and MRM chromatogram. According to the fragment character of saponins, the molecular weight and their structures could be identified. The method can be used for qualitative analysis of saponins from Panax notoginseng.

  1. Determination of 16 insect growth regulators in edible Chinese traditional herbs by liquid chromatography electrospray tandem mass spectrometry.

    Science.gov (United States)

    Qian, Mingrong; Wu, Liqin; Zhang, Hu; Xu, Mingfei; Li, Rui; Wang, Xiangyun; Sun, Caixia

    2012-03-01

    A new sensitive multiresidue liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical method for the determination of 16 insect growth regulator (IGR) residues-RH-5849 (1,2-dibenzoyl-1-tert-butylhydrazine), halofenozide, methoxyfenozide, chromafenozide, fufenozide, tebufenozide, diflubenzuron, chlorbenzuron, triflumuron, hexaflumuron, novaluron, lufenuron, teflubenzuron, flucycloxuron, flufenoxuron, and chlorfluazuron-in herbs (Perilla frutescens, flos chrysanthemi, lily bulbs, and ginger) has been developed. After the herbs had been extracted with acetonitrile, a combined graphitized nonporous carbon/aminopropyl (ENVI-Carb/LC-NH(2)) cartridge and a Florisil cartridge were used to clean up the extracts. LC-MS/MS was performed in multiple reaction monitoring mode with two specific precursor ion-product ion transitions per IGR to confirm and quantitate the residues in herbs. Quantitation was performed on the basis of matrix-matched calibrations. The method showed excellent linearity (r(2) > 0.99) and precision (relative standard deviations of 13.6 or lower) for all the target insecticides. The limits of quantitation were 0.6-10 μg kg(-1) for the 16 insecticides in the four herbs. The average recoveries, measured at three concentrations (0.01, 0.1, 1 mg kg(-1)), were in the range 74.8-105.3%. The method was satisfactorily applied for the analysis of 60 herb samples (Perilla frutescens, flos chrysanthemi, lily bulbs, and ginger). Hexaflumuron was detected at concentrations of 0.029 and 0.051 mg kg(-1) in Perilla frutescens.

  2. Determination of Bile Acids in Piglet Bile by Solid Phase Extraction and Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    Science.gov (United States)

    Mi, Si; Lim, David W; Turner, Justine M; Wales, Paul W; Curtis, Jonathan M

    2016-03-01

    An LC/MS/MS-based method was developed for the determination of individual bile acids (BA) and their conjugates in porcine bile samples. The C18-based solid-phase extraction (SPE) procedure was optimized so that all 19 target BA and their glycine and taurine conjugates were collected with high recoveries for standards (89.1-100.2%). Following this, all 19 compounds were separated and quantified in a single 12 min chromatographic run. The method was validated in terms of linearity, sensitivity, accuracy, precision, and recovery. An LOD in the low ppb range with measured precisions in the range of 0.5-9.3% was achieved. The recoveries for all of the 19 analytes in bile samples were all >80%. The validated method was successfully applied to the profiling of BA and their conjugates in the bile from piglets treated with exogenous glucagon-like peptide-2 (GLP-2) in a preclinical model of neonatal parenteral nutrition-associated liver disease (PNALD). The method developed is rapid and could be easily implemented for routine analysis of BA and their conjugates in other biofluids or tissues.

  3. Characterisation of tryptic peptides of phosphorylated tyrosine hydroxylase by high-pressure liquid chromatography electrospray ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Graham, Mark E.; Dickson, Phillip W.; Dunkley, Peter R.; Nagy-Felsobuki, Ellak I. von

    2005-01-01

    Tyrosine hydroxylase (TH) is involved in the biosynthesis of catecholamines and is activated by phosphorylation. Phosphorylated TH was analysed using high-pressure liquid chromatography combined with electrospray mass spectrometry (HPLC ESI-MS). Two mass scanning methods were used to detect tryptic cleavage products of TH. In the positive electrospray ionisation mode (ESI+), the peptides that contain the phosphorylation sites of TH were identified. In the alternative method, a phosphopeptide was detected in the negative electrospray ionisation mode (ESI-) using single ion monitoring in combination with a sequential ESI+ switching experiment. A raised baseline interfered with detection of hydrophilic peptides in ESI-, with the signal-to-noise ratio indicating that the method was operating near the limit of detection for a conventional electrospray source. The switching method improved the certainty of identification of phosphopeptides

  4. Multi residue screening of intact testosterone esters and boldenone undecylenate in bovine hair using liquid chromatography electrospray tandem mass spectrometry

    NARCIS (Netherlands)

    Nielen, M.W.F.; Lasaroms, J.J.P.; Mulder, P.P.J.; Hende, van J.; Rhijn, van J.A.; Groot, M.J.

    2006-01-01

    The abuse of esters of natural androgenic steroids in cattle fattening and sports is hard to control via routine urine testing. The esters are rapidly hydrolysed in vivo into substances which are also endogenously present in urine. In veterinary control strange findings of 17ß-testosterone and

  5. Applications of ionizing radiations

    International Nuclear Information System (INIS)

    2014-01-01

    Developments in standard applications and brand new nuclear technologies, with high impact on the future of the agriculture, medicine, industry and the environmental preservation. The Radiation Technology Center (CTR) mission is to apply the radiation and radioisotope technologies in Industry, Health, Agriculture, and Environmental Protection, expanding the scientific knowledge, improving human power resources, transferring technology, generating products and offering services for the Brazilian society. The CTR main R and D activities are in consonance with the IPEN Director Plan (2011-2013) and the Applications of Ionizing Radiation Program, with four subprograms: Irradiation of Food and Agricultural Products; Radiation and Radioisotopes Applications in Industry and Environment; Radioactive Sources and Radiation Applications in Human Health; and Radioactive Facilities and Equipment for the Applications of Nuclear Techniques

  6. Reference ionization chamber

    International Nuclear Information System (INIS)

    Golnik, N.; Zielczynski, M.

    1999-01-01

    The paper presents the design of ionization chamber devoted for the determination of the absolute value of the absorbed dose in tissue-equivalent material. The special attention was paid to ensure that the volume of the active gas cavity was constant and well known. A specific property of the chamber design is that the voltage insulators are 'invisible' from any point of the active volume. Such configuration ensures a very good time stability of the electrical field and defines the active volume. The active volume of the chamber was determined with accuracy of 0.3%. This resulted in accuracy of 0.8% in determination of the absorbed dose in the layer of material adherent to the gas cavity. The chamber was applied for calibration purposes at radiotherapy facility in Joint Institute for Nuclear Research in Dubna (Russia) and in the calibration laboratory of the Institute of Atomic Energy in Swierk. (author)

  7. Applications of ionizing radiations

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-07-01

    Developments in standard applications and brand new nuclear technologies, with high impact on the future of the agriculture, medicine, industry and the environmental preservation. The Radiation Technology Center (CTR) mission is to apply the radiation and radioisotope technologies in Industry, Health, Agriculture, and Environmental Protection, expanding the scientific knowledge, improving human power resources, transferring technology, generating products and offering services for the Brazilian society. The CTR main R and D activities are in consonance with the IPEN Director Plan (2011-2013) and the Applications of Ionizing Radiation Program, with four subprograms: Irradiation of Food and Agricultural Products; Radiation and Radioisotopes Applications in Industry and Environment; Radioactive Sources and Radiation Applications in Human Health; and Radioactive Facilities and Equipment for the Applications of Nuclear Techniques.

  8. Ionizing radiation detector

    Science.gov (United States)

    Thacker, Louis H.

    1990-01-01

    An ionizing radiation detector is provided which is based on the principle of analog electronic integration of radiation sensor currents in the sub-pico to nano ampere range between fixed voltage switching thresholds with automatic voltage reversal each time the appropriate threshold is reached. The thresholds are provided by a first NAND gate Schmitt trigger which is coupled with a second NAND gate Schmitt trigger operating in an alternate switching state from the first gate to turn either a visible or audible indicating device on and off in response to the gate switching rate which is indicative of the level of radiation being sensed. The detector can be configured as a small, personal radiation dosimeter which is simple to operate and responsive over a dynamic range of at least 0.01 to 1000 R/hr.

  9. Transport processes in ionized gases

    International Nuclear Information System (INIS)

    Kremer, G.M.

    1997-01-01

    Based on kinetic theory of gases and on the combined of Chapman-Enskog and Grad, the laws of Ohm, Fourier and Navier-Stokes are derived for a non-relativistic fully ionized gas. Moreover, the combined method is applied to the BGK model of the relativistic Boltzmann equation and the Ohm's law is derived for a relativistic fully ionized gas. (author)

  10. Amorphous silicon ionizing particle detectors

    Science.gov (United States)

    Street, Robert A.; Mendez, Victor P.; Kaplan, Selig N.

    1988-01-01

    Amorphous silicon ionizing particle detectors having a hydrogenated amorphous silicon (a--Si:H) thin film deposited via plasma assisted chemical vapor deposition techniques are utilized to detect the presence, position and counting of high energy ionizing particles, such as electrons, x-rays, alpha particles, beta particles and gamma radiation.

  11. Worldwide exposures to ionizing radiation

    International Nuclear Information System (INIS)

    Bennett, B.G.

    1993-01-01

    All of mankind is exposed to ionizing radiation from natural sources, from human practices that release natural and artificial radionuclides to the environment, and from medical radiation procedures. This paper reviews the assessment in the UNSCEAR 1993 Report of the exposures of human populations worldwide to the various sources of ionizing radiation

  12. Food ionizing treatment

    International Nuclear Information System (INIS)

    Strasser, A.; Raffi, J.; Hasselmann, C.

    1997-01-01

    Treatment of food with ionizing radiation is increasingly being recognized as a means of reducing food-borne illnesses and associated medical and other costs. In addition, the process may contribute to food security by preventing post-harvest losses, thereby making more food available to more people, eventually at lower cost. An ever increasing number of countries has approved the irradiation of a long and growing list of different food items, groups of classes, ranging from spices to grains to fruit and vegetables to meats and poultry and seafood. However, perception by consumers has been controversial and concerns have been expressed, particularly related to the safety of irradiated food. Therefore, the toxicological aspects of irradiated food are addressed in this dossier. It should be recognized that food irradiation is perhaps the most thoroughly investigated food processing technology. According to the World Health Organization 'irradiated food produced in accordance with established Good Manufacturing Practice can be considered safe and nutritionally adequate'. A recent evaluation by a WHO/FAO/IAEA study group (Geneva, Sept. 1997) even came to the conclusion, 'that as long as sensory qualities of food are retained and harmful microorganisms are destroyed, the actual amount of ionizing radiation applied is of secondary consideration'. Thus, also treatment of food with doses greater than the currently recommended upper level of 10 kGy by the Codex Alimentarius Commission will not lead to changes in the composition of the food that, from a toxicological point of view, would have an adverse effect on human health. (author)

  13. Ionization detection system for aerosols

    International Nuclear Information System (INIS)

    Jacobs, M.E.

    1977-01-01

    This invention relates to an improved smoke-detection system of the ionization-chamber type. In the preferred embodiment, the system utilizes a conventional detector head comprising a measuring ionization chamber, a reference ionization chamber, and a normally non-conductive gas triode for discharging when a threshold concentration of airborne particulates is present in the measuring chamber. The improved system utilizes a measuring ionization chamber which is modified to minimize false alarms and reductions in sensitivity resulting from changes in ambient temperature. In the preferred form of the modification, an annular radiation shield is mounted about the usual radiation source provided to effect ionization in the measuring chamber. The shield is supported by a bimetallic strip which flexes in response to changes in ambient temperature, moving the shield relative to the source so as to vary the radiative area of the source in a manner offsetting temperature-induced variations in the sensitivity of the chamber. 8 claims, 7 figures

  14. Laser-enhanced ionization spectroscopy around the ionization limit

    International Nuclear Information System (INIS)

    Axner, O.; Berglind, T.; Sjoestroem, S.

    1986-01-01

    Laser-induced photoionization and Laser-Enhanced collision Ionization (LEI) of Na, Tl, and Li in flames are detected by measuring the production of charges following a laser excitation. The ionization signal is investigated for excitations of the atoms from lower lying states both to Rydberg states close to the ionization limit, as well as to continuum states, i.e. the process of collision ionization is compared with that of photoionization. The qualitative behaviour of the ionization signal when scanning across the ionization limit is studied. It is shown that the ionization signal has a smooth behaviour when passing from bound states into continuum states. The laser-induced photoionization signal strength of atoms in flames is both calculated and measured and a good agreement is obtained. A calculation of wavelength dependent photoionization signal strengths for a number of elements is also presented. Photoionization is used to determine flame- and geometry-dependent parameters. An implication of photoionization in connection with LEI spectrometry for trace element analysis is that there will be a significant increase in background noise if the sample contains high concentrations of easily photoionizing elements and short wavelength light is used. (orig.)

  15. Ionization effects in electronic inner-shells of ionized atoms

    International Nuclear Information System (INIS)

    Shchornak, G.

    1983-01-01

    A review of the atomic physics of ionization atoms has been presented. Interaction and structure effects in atomic shells, correlated to the occurrence of vacancies in several subshells of the atom have been considered. The methods of calculations of atomic states and wave functions have been reviewed. The energy shift of characteristic X-rays is discussed as a function of the ionization stage of the atom. The influence of inner and outer-shell vacancies on the energy of the X-rays is shown in detail. The influence of chemical effects on the parameters of X-rays is also taken into account. Further on, the change of transition probabilities in radiative and non-radiative transitions by changing stage of ionization is discussed; and among them the leading part of Auger and Coster-Kronig transitions by the arearrangement of the atomic states is shown. The influence of non-radiative electronic transitions on ionization cross-sections for multiple ionization is discussed. Using these results, ionization cross-sections for direct and indirect processes for several ionization stages are given

  16. Photoionization effects in ionization fronts

    International Nuclear Information System (INIS)

    Arrayas, Manuel; Fontelos, Marco A; Trueba, Jose L

    2006-01-01

    In this paper we study the effects of photoionization processes on the propagation of both negative and positive ionization fronts in streamer discharge. We show that negative fronts accelerate in the presence of photoionization events. The appearance and propagation of positive ionization fronts travelling with constant velocity is explained as the result of the combined effects of photoionization and electron diffusion. The photoionization range plays an important role in the selection of the velocity of the ionization front as we show in this work

  17. Photoionization effects in ionization fronts

    Energy Technology Data Exchange (ETDEWEB)

    Arrayas, Manuel [Departamento de Electromagnetismo, Universidad Rey Juan Carlos, Tulipan s/n, 28933 Mostoles, Madrid (Spain); Fontelos, Marco A [Departamento de Matematicas, Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones CientIficas, C/Serrano 123, 28006 Madrid (Spain); Trueba, Jose L [Departamento de Electromagnetismo, Universidad Rey Juan Carlos, Tulipan s/n, 28933 Mostoles, Madrid (Spain)

    2006-12-21

    In this paper we study the effects of photoionization processes on the propagation of both negative and positive ionization fronts in streamer discharge. We show that negative fronts accelerate in the presence of photoionization events. The appearance and propagation of positive ionization fronts travelling with constant velocity is explained as the result of the combined effects of photoionization and electron diffusion. The photoionization range plays an important role in the selection of the velocity of the ionization front as we show in this work.

  18. Ionizing radiation promotes protozoan reproduction

    International Nuclear Information System (INIS)

    Luckey, T.D.

    1986-01-01

    This experiment was performed to determine whether ionizing radiation is essential for maximum growth rate in a ciliated protozoan. When extraneous ionizing radiation was reduced to 0.15 mrad/day, the reproduction rate of Tetrahymena pyriformis was significantly less (P less than 0.01) than it was at near ambient levels, 0.5 or 1.8 mrad/day. Significantly higher growth rates (P less than 0.01) were obtained when chronic radiation was increased. The data suggest that ionizing radiation is essential for optimum reproduction rate in this organism

  19. Nonlinear modulation of ionization waves

    International Nuclear Information System (INIS)

    Bekki, Naoaki

    1981-01-01

    In order to investigate the nonlinear characteristics of ionization waves (moving-striations) in the positive column of glow discharge, a nonlinear modulation of ionization waves in the region of the Pupp critical current is analysed by means of the reductive perturbation method. The modulation of ionization waves is described by a nonlinear Schroedinger type equation. The coefficients of the equation are evaluated using the data of the low pressure Argon-discharge, and the simple solutions (plane wave and envelope soliton type solutions) are presented. Under a certain condition an envelope soliton is propagated through the positive column. (author)

  20. Ionization of liquids

    International Nuclear Information System (INIS)

    Gregg, E.C.; Bakale, G.

    1976-01-01

    Application of pulsed-conductivity techniques to ionization phenomena in liquids has yielded new results on electron transport and electron reactions in nonpolar liquids which we have extrapolated to biological systems to develop a novel model of direct radiation damage to mammalian cells that involves the unsolvated electron as the key reactant. Among these new results are electron attachment rate constants of thirty-five substituted nitrobenzene compounds measured in nonpolar solvents which when combined with product anion lifetimes are correlated with cellular radiosensitization efficiencies. From this study we found that electron attachment rates are dependent upon the electron mobility in the solvents and upon the dipole moment of the electron-accepting nitrobenzene compounds. The model also drawn upon energy-dependent electron attachment rates which we have measured in cryogenic liquids, and we have measured in the same solvents associative detachment rate constants and electron momentum transfer cross sections. In addition to these studies of electronic processes in liquids, we have measured ion mobilities of lecithin and chlorophyll in nonpolar solvents and conclude that these solutes form inverse micelles under certain conditions. Formation of these micelles permits electron transport through the lipid micellar walls and electron attachment to electron-accepting polar solutes inside the lipid vesicles to be studied

  1. Ionization in liquids

    International Nuclear Information System (INIS)

    Bakale, G.

    1990-01-01

    During the 1987--1990 reporting period, studies were conducted that entailed the direct measurement of the transport and reaction properties of excess electrons in nonpolar liquids through the use of pulse-conductivity techniques. The results obtained from these studies should be applicable toward the development of a better understanding of the primary ionizing event in liquids as well as to providing physico-chemical information that is pertinent to electron-transfer processes that are ubiquitous in biological systems. Progress was also made in developing a better understanding of electron attachment reactions in liquids through measurements of the electron attachment rate constants, k e s, of a variety of electron-attaching solutes. The effects of several functional groups substituted at different positions on benzene were studied in liquid cyclohexane and isooctane. The electron-attaching properties of chemicals having well characterized carcinogenic properties were studied in cyclohexane to determine if the measure of electron-accepting potential that k e provides can elucidate the role that electrons play in the initiation step of carcinogenesis. The k e s that were measured indicate that the k e -carcinogenicity correlation that was observed can be used to complement short-term carcinogen-screening bioassays to identify potential carcinogens. 115 refs., 6 tabs

  2. Physics of partially ionized plasmas

    CERN Document Server

    Krishan, Vinod

    2016-01-01

    Plasma is one of the four fundamental states of matter; the other three being solid, liquid and gas. Several components, such as molecular clouds, diffuse interstellar gas, the solar atmosphere, the Earth's ionosphere and laboratory plasmas, including fusion plasmas, constitute the partially ionized plasmas. This book discusses different aspects of partially ionized plasmas including multi-fluid description, equilibrium and types of waves. The discussion goes on to cover the reionization phase of the universe, along with a brief description of high discharge plasmas, tokomak plasmas and laser plasmas. Various elastic and inelastic collisions amongst the three particle species are also presented. In addition, the author demonstrates the novelty of partially ionized plasmas using many examples; for instance, in partially ionized plasma the magnetic induction is subjected to the ambipolar diffusion and the Hall effect, as well as the usual resistive dissipation. Also included is an observation of kinematic dynam...

  3. Resonance Ionization Laser Ion Sources

    CERN Document Server

    Marsh, B

    2013-01-01

    The application of the technique of laser resonance ionization to the production of singly charged ions at radioactive ion beam facilities is discussed. The ability to combine high efficiency and element selectivity makes a resonance ionization laser ion source (RILIS) an important component of many radioactive ion beam facilities. At CERN, for example, the RILIS is the most commonly used ion source of the ISOLDE facility, with a yearly operating time of up to 3000 hours. For some isotopes the RILIS can also be used as a fast and sensitive laser spectroscopy tool, provided that the spectral resolution is sufficiently high to reveal the influence of nuclear structure on the atomic spectra. This enables the study of nuclear properties of isotopes with production rates even lower than one ion per second and, in some cases, enables isomer selective ionization. The solutions available for the implementation of resonance laser ionization at radioactive ion beam facilities are summarized. Aspects such as the laser r...

  4. Safe use of ionizing radiations

    Energy Technology Data Exchange (ETDEWEB)

    1973-01-01

    Based on the ''Code of Practice for the protection of persons against ionizing radiations arising from medical and dental use'' (CIS 74-423), this handbook shows how hospital staff can avoid exposing themselves and others to these hazards. It is designed particularly for junior and student nurses. Contents: ionizing radiations, their types and characteristics; their uses and dangers; basic principles in their safe use; safe use in practice; explanation of terms.

  5. Biomedical applications of ionizing radiation

    International Nuclear Information System (INIS)

    Rosiak, J.M.; Pietrzak, M.

    1997-01-01

    Application of ionizing radiation for sterilization of medical devices, hygienization of cosmetics products as well as formation of biomaterials have been discussed. The advantages of radiation sterilization over the conventional methods have been indicated. The properties of modern biomaterials, hydrogels as well as some ways of their formation and modification under action of ionizing radiation were presented. Some commercial biomaterials of this kind produced in accordance with original Polish methods by means of radiation technique have been pointed out. (author)

  6. Modeling ionization by helicon waves

    International Nuclear Information System (INIS)

    Degeling, A.W.; Boswell, R.W.

    1997-01-01

    The response of the electron distribution function in one dimension to a traveling wave electric field is modeled for parameters relevant to a low-pressure helicon wave plasma source, and the resulting change in the ionization rate calculated. This is done by calculating the trajectories of individual electrons in a given wave field and assuming no collisions to build up the distribution function as the distance from the antenna is increased. The ionization rate is calculated for argon by considering the ionization cross section and electron flux at a specified position and time relative to the left-hand boundary, where the distribution function is assumed to be Maxwellian and the wave travels to the right. The simulation shows pulses in the ionization rate that move away from the antenna at the phase velocity of the wave, demonstrating the effect of resonant electrons trapped in the wave close-quote s frame of reference. It is found that the ionization rate is highest when the phase velocity of the wave is between 2 and 3x10 6 m/s, where the electrons interacting strongly with the wave (i.e., electrons with velocities inside the wave close-quote s open-quotes trapping widthclose quotes) have initial energies just below the ionization threshold. Results from the model are compared with experimental data and show reasonable qualitative agreement. copyright 1997 American Institute of Physics

  7. Resonance ionization scheme development for europium

    Energy Technology Data Exchange (ETDEWEB)

    Chrysalidis, K., E-mail: katerina.chrysalidis@cern.ch; Goodacre, T. Day; Fedosseev, V. N.; Marsh, B. A. [CERN (Switzerland); Naubereit, P. [Johannes Gutenberg-Universität, Institiut für Physik (Germany); Rothe, S.; Seiffert, C. [CERN (Switzerland); Kron, T.; Wendt, K. [Johannes Gutenberg-Universität, Institiut für Physik (Germany)

    2017-11-15

    Odd-parity autoionizing states of europium have been investigated by resonance ionization spectroscopy via two-step, two-resonance excitations. The aim of this work was to establish ionization schemes specifically suited for europium ion beam production using the ISOLDE Resonance Ionization Laser Ion Source (RILIS). 13 new RILIS-compatible ionization schemes are proposed. The scheme development was the first application of the Photo Ionization Spectroscopy Apparatus (PISA) which has recently been integrated into the RILIS setup.

  8. Increased ionization rate in laser enrichment

    International Nuclear Information System (INIS)

    Janes, G.S.; Pike, G.T.

    1977-01-01

    A system employing multiple, upper excitation levels in a technique for isotopically selective ionization to improve the ionization efficiency is described. Laser radiation is employed to excite particles with isotopic selectivity. Excitation is produced to a plurality of excited states below the ionization level with the result of increasing the number of available excited particles for ionization and thereby increasing the ionization cross section for improved system efficiency

  9. Ambient ionization mass spectrometry: A tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Min-Zong; Cheng, Sy-Chi; Cho, Yi-Tzu [Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan (China); Shiea, Jentaie, E-mail: jetea@fac.nsysu.edu.tw [Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan (China); Cancer Center, Kaohsiung Medical University, Kaohsiung, Taiwan (China)

    2011-09-19

    Highlights: {yields} Ambient ionization technique allows the direct analysis of sample surfaces with little or no sample pretreatment. {yields} We sort ambient ionization techniques into three main analytical strategies, direct ionization, direct desorption/ionization, and two-step ionization. {yields} The underlying principles of operation, ionization processes, detecting mass ranges, sensitivity, and representative applications of these techniques are described and compared. - Abstract: Ambient ionization is a set of mass spectrometric ionization techniques performed under ambient conditions that allows the direct analysis of sample surfaces with little or no sample pretreatment. Using combinations of different types of sample introduction systems and ionization methods, several novel techniques have been developed over the last few years with many applications (e.g., food safety screening; detection of pharmaceuticals and drug abuse; monitoring of environmental pollutants; detection of explosives for antiterrorism and forensics; characterization of biological compounds for proteomics and metabolomics; molecular imaging analysis; and monitoring chemical and biochemical reactions). Electrospray ionization and atmospheric pressure chemical ionization are the two main ionization principles most commonly used in ambient ionization mass spectrometry. This tutorial paper provides a review of the publications related to ambient ionization techniques. We describe and compare the underlying principles of operation, ionization processes, detecting mass ranges, sensitivity, and representative applications of these techniques.

  10. Ambient ionization mass spectrometry: A tutorial

    International Nuclear Information System (INIS)

    Huang, Min-Zong; Cheng, Sy-Chi; Cho, Yi-Tzu; Shiea, Jentaie

    2011-01-01

    Highlights: → Ambient ionization technique allows the direct analysis of sample surfaces with little or no sample pretreatment. → We sort ambient ionization techniques into three main analytical strategies, direct ionization, direct desorption/ionization, and two-step ionization. → The underlying principles of operation, ionization processes, detecting mass ranges, sensitivity, and representative applications of these techniques are described and compared. - Abstract: Ambient ionization is a set of mass spectrometric ionization techniques performed under ambient conditions that allows the direct analysis of sample surfaces with little or no sample pretreatment. Using combinations of different types of sample introduction systems and ionization methods, several novel techniques have been developed over the last few years with many applications (e.g., food safety screening; detection of pharmaceuticals and drug abuse; monitoring of environmental pollutants; detection of explosives for antiterrorism and forensics; characterization of biological compounds for proteomics and metabolomics; molecular imaging analysis; and monitoring chemical and biochemical reactions). Electrospray ionization and atmospheric pressure chemical ionization are the two main ionization principles most commonly used in ambient ionization mass spectrometry. This tutorial paper provides a review of the publications related to ambient ionization techniques. We describe and compare the underlying principles of operation, ionization processes, detecting mass ranges, sensitivity, and representative applications of these techniques.

  11. Down syndrome and ionizing radiation.

    Science.gov (United States)

    Verger, P

    1997-12-01

    This review examines the epidemiologic and experimental studies into the possible role ionizing radiation might play in Down Syndrome (trisomy 21). It is prompted by a report of a temporal cluster of cases of this chromosomal disorder observed in West Berlin exactly 9 mo after the radioactive cloud from Chernobyl passed. In approximately 90% of cases, Down Syndrome is due to the nondisjunction of chromosome 21, most often in the oocyte, which may be exposed to ionizing radiation during two separate periods: before the completion of the first meiosis or around the time of ovulation. Most epidemiologic studies into trisomies and exposure to ionizing radiation examine only the first period; the Chernobyl cluster is related to the second. Analysis of these epidemiologic results indicates that the possibility that ionizing radiation might be a risk factor in Down Syndrome cannot be excluded. The experimental results, although sometimes contradictory, demonstrate that irradiation may induce nondisjunction in oogenesis and spermatogenesis; they cannot, however, be easily extrapolated to humans. The weaknesses of epidemiologic studies into the risk factors for Down Syndrome at birth (especially the failure to take into account the trisomy cases leading to spontaneous abortion) are discussed. We envisage the utility and feasibility of new studies, in particular among women exposed to prolonged or repeated artificially-produced ionizing radiation.

  12. Health effects of ionizing radiation

    International Nuclear Information System (INIS)

    Pathak, B.

    1989-12-01

    Ionizing radiation is energy that travels through space as electromagnetic waves or a stream of fast moving particles. In the workplace, the sources of ionizing radiation are radioactive substances, nuclear power plants, x-ray machines and nuclear devices used in medicine, research and industry. Commonly encountered types of radiation are alpha particles, beta particles and gamma rays. Alpha particles have very little penetrating power and pose a risk only when the radioactive substance is deposited inside the body. Beta particles are more penetrating than alpha particles and can penetrate the outer body tissues causing damage to the skin and the eyes. Gamma rays are highly penetrating and can cause radiation damage to the whole body. The probability of radiation-induced disease depends on the accumulated amount of radiation dose. The main health effects of ionizing radiation are cancers in exposed persons and genetic disorders in the children, grandchildren and subsequent generations of the exposed parents. The fetus is highly sensitive to radiation-induced abnormalities. At high doses, radiation can cause cataracts in the eyes. There is no firm evidence that ionizing radiation causes premature aging. Radiation-induced sterility is highly unlikely for occupational doses. The data on the combined effect of ionizing radiation and other cancer-causing physical and chemical agents are inconclusive

  13. Ionization equilibrium in dense plasmas

    International Nuclear Information System (INIS)

    Ying, R.

    1987-01-01

    The average degree of ionization for a strongly coupled plasma is investigated and calculated. Two widely used approaches: the Saha equation method and the Thomas-Fermi (TF) statistical atomic model are adopted to determine the degree of ionization. Both methods are modified in a number of ways to include the strong-coupling effect in the plasma. In the Saha equation approach, the strong-coupling effects are introduced through: (i) a replacement of the Coulomb potential by a screened Debye potential; (ii) adoption of the Planck-Larkin partition function; (iii) description of the electron component by Fermi-Dirac statistics. The calculated degree of ionization exceeds that obtained from the original Saha equation, exhibits a minimum as a function of the density and shows an abrupt phase transition from weakly ionized to a fully ionized state. The zero-temperature TF model for compressed ions and the finite-temperature TF model for ions are investigated for the first time. In order to take into account the strong-coupling effect in a systematic way, a strong-coupling TF model is set up. Favorable results with the relatively simple approximations indicate that the newly established strong-coupling TF model is a more systematic and physically consistent approach

  14. Display of charged ionizing particles

    International Nuclear Information System (INIS)

    Cano S, D.; Ortiz A, M. D.; Amarillas S, L. E.; Vega C, H. R.

    2017-10-01

    The human being is exposed to sources of ionizing and non-ionizing radiation, both of natural or anthropogenic origin. None of these, except non-ionizing such as visible light and infrared radiation, can be detected by the sense of sight and touch respectively. The sun emits charged particles with speeds close to the light that interact with the atoms of the gases present in the atmosphere, producing nuclear reactions that in turn produce other particles that reach the surface of the Earth and reach the living beings. On Earth there are natural radioisotopes that, when they disintegrate, emit ionizing radiation that contributes to the dose we receive. A very old system that allows the visualization of the trajectories of the charged ionizing particles is the Fog Chamber that uses a saturated steam that when crossed by particles with mass and charge, as alpha and beta particles produce condensation centers along its path leaves a trace that can be seen. The objective of this work was to build a fog chamber using easily accessible materials. To measure the functioning of the fog chamber, cosmic rays were measured, as well as a source of natural metal uranium. The fog chamber allowed seeing the presence of traces in alcohol vapor that are produced in a random way. Introducing the uranium foil inside the fog chamber, traces of alpha particles whose energy varies from 4 to 5 MeV were observed. (Author)

  15. Technical sheets of ionizing radiations. 2. Non-ionizing radiations

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    The biological effects of different non-ionizing radiations are studied: ultra-violet radiation, visible radiation, infrared radiation, micrometric waves, ultrasonics. In spite of their apparent diversity these radiations are similar in their physico-chemical effects, but in view of their widely varying production methods and types of application each type is considered separately. It is pointed out that no organization resembling the CIPR exists in the field of non-ionizing radiations, the result being a great disparity amongst the different legislations in force [fr

  16. Cytochrome C is tyrosine 97 phosphorylated by neuroprotective insulin treatment.

    Directory of Open Access Journals (Sweden)

    Thomas H Sanderson

    Full Text Available Recent advancements in isolation techniques for cytochrome c (Cytc have allowed us to discover post-translational modifications of this protein. We previously identified two distinct tyrosine phosphorylated residues on Cytc in mammalian liver and heart that alter its electron transfer kinetics and the ability to induce apoptosis. Here we investigated the phosphorylation status of Cytc in ischemic brain and sought to determine if insulin-induced neuroprotection and inhibition of Cytc release was associated with phosphorylation of Cytc. Using an animal model of global brain ischemia, we found a ∼50% decrease in neuronal death in the CA1 hippocampal region with post-ischemic insulin administration. This insulin-mediated increase in neuronal survival was associated with inhibition of Cytc release at 24 hours of reperfusion. To investigate possible changes in the phosphorylation state of Cytc we first isolated the protein from ischemic pig brain and brain that was treated with insulin. Ischemic brains demonstrated no detectable tyrosine phosphorylation. In contrast Cytc isolated from brains treated with insulin showed robust phosphorylation of Cytc, and the phosphorylation site was unambiguously identified as Tyr97 by immobilized metal affinity chromatography/nano-liquid chromatography/electrospray ionization mass spectrometry. We next confirmed these results in rats by in vivo application of insulin in the absence or presence of global brain ischemia and determined that Cytc Tyr97-phosphorylation is strongly induced under both conditions but cannot be detected in untreated controls. These data suggest a mechanism whereby Cytc is targeted for phosphorylation by insulin signaling, which may prevent its release from the mitochondria and the induction of apoptosis.

  17. Ionizing energy treatment of poultry

    International Nuclear Information System (INIS)

    Mulder, R.W.A.W.

    1983-01-01

    The application of an ionizing energy treatment to poultry carcasses results in a decrease of the number of potentially pathogenic microorganisms, e.g. Salmonellae. At the same time the refrigerated shelf life of treated poultry products is considerably increased. To achieve these beneficial effects doses ranging from 2.00 to 9.00 kGy are needed, but in poultry doses over 5.00 kGy may cause undesirable side-effects. To asses the microbiological quality of ionizing radiation treated end-products adequate isolation methods should be used to include all sublethally injured microorganisms in the colony counts. The assessment of the required lethality of an ionizing energy treatment is difficult as D 10 (decimal reduction) - values depend greatly on several parameters

  18. Ionization of nitrogen cluster beam

    International Nuclear Information System (INIS)

    Yano, Katsuki; Be, S.H.; Enjoji, Hiroshi; Okamoto, Kosuke

    1975-01-01

    A nitrogen cluster beam (neutral particle intensity of 28.6 mAsub(eq)) is ionized by electron collisions in a Bayard-Alpert gauge type ionizer. The extraction efficiency of about 65% is obtained at an electron current of 10 mA with an energy of 50 eV. The mean cluster size produced at a pressure of 663 Torr and temperature of 77.3 K is 2x10 5 molecules per cluster. By the Coulomb repulsion force, multiply ionized cluster ions are broken up into smaller fragments and the cluster ion size reduces to one-fourth at an electron current of 15 mA. Mean neutral cluster sizes depend strongly on the initial degree of saturation PHI 0 and are 2x10 5 , 7x10 4 and 3x10 4 molecules per cluster at PHI 0 's of 0.87, 0.66 and 0.39, respectively. (auth.)

  19. Spectroscopy of highly ionized atoms

    International Nuclear Information System (INIS)

    Livingston, A.E.

    1987-01-01

    The atomic structure and decay characteristics of excited states in multiply ionized atoms represent a fertile testing ground for atomic calculations ranging from accurate ab initio theory for few-electron systems to practical semi-empirical approaches for many-electron species. Excitation of fast ions by thin foils generally produces the highest ionization stages for heavy ions in laboratory sources. The associated characteristics of spectroscopic purity and high time resolution provide unique capabilities for studying the atomic properties of highly-ionized atoms. This report is limited to a brief discussion of three classes of atomic systems that are experiencing current theoretical and experimental interest: precision structure of helium-like ions, fine structure of doubly-excited states, and lifetimes of metastable states. Specific measurements in each of these types of systems are mentioned, with emphasis on the relation to studies involving slow, highly-charged ions

  20. Prenatal exposition on ionizing radiations

    International Nuclear Information System (INIS)

    2001-01-01

    The Sessions on Prenatal Exposition on Ionizing Radiations was organized by the Argentine Radioprotection Society, in Buenos Aires, between 8 and 9, November 2001. In this event, were presented papers on: biological effects of ionizing radiation; the radiation protection and the pregnant woman; embryo fetal development and its relationship with the responsiveness to teratogens; radioinduced delayed mental; neonatal irradiation: neurotoxicity and modulation of pharmacological response; pre implanted mouse embryos as a model of uranium toxicity studies; hereditary effects of the radiation and new advances from the UNSCEAR 2001; doses estimation in embryo

  1. Ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki

    2010-01-01

    resolution and high sensitivity are necessary. For exact dosimetry which is done using ionization chambers (ICs), the recombination taking place in the IC has to be known. Up to now, recombination is corrected phenomenologically and more practical approaches are currently used. Nevertheless, Jaff´e's theory...... of columnar recombination was designed to model the detector efficiency of an ionization chamber. Here, we have shown that despite the approximations and simplification made, the theory is correct for the LETs typically found in clinical radiotherapy employing particles from protons to carbon ions...

  2. Stimulating effects of ionizing radiation

    International Nuclear Information System (INIS)

    Jaworowski, Z.

    1995-01-01

    The influence of low doses on human organism is not definite known up to now. The worldwide discussion on this topic has been presented. A lot of analysed statistical data proved that the stimulating effect of low doses of ionizing radiation really exists and can have a beneficial influence on human health. 43 refs, 4 figs, 6 tabs

  3. Food irradiation with ionizing radiation

    International Nuclear Information System (INIS)

    Hrudkova, A.; Pohlova, M.; Sedlackova, J.

    1974-01-01

    Application possibilities are discussed of ionizing radiation in inhibiting plant germination, in radiopasteurization and radiosterilization of food. Also methods of combining radiation with thermal food sterilization are discussed. The problems of radiation doses and of hygienic purity of irradiated foodstuffs are dealt with. (B.S.)

  4. Trends in resonance ionization spectroscopy

    International Nuclear Information System (INIS)

    Hurst, G.S.

    1986-01-01

    The author reviews the history of resonance ionization spectroscopy and then comments on the delineations of RIS with reference to many related laser processes. The substance of the paper deals with the trends in RIS and especially how the needs for sensitive analytical methods have overshadowed the orginal plan to study excited species. 9 refs., 1 fig

  5. Multiphoton ionization of atomic cesium

    International Nuclear Information System (INIS)

    Compton, R.N.; Klots, C.E.; Stockdale, J.A.D.; Cooper, C.D.

    1984-01-01

    We describe experimental studies of resonantly enhanced multi-photon ionization (MPI) of cesium atoms in the presence and absence of an external electric field. In the zero-field studies, photo-electron angular distributions for one- and two-photon resonantly enhanced MPI are compared with the theory of Tang and Lambropoulos. Deviations of experiment from theory are attributed to hyperfine coupling effects in the resonant intermediate state. The agreement between theory and experiment is excellent. In the absence of an external electric field, signal due to two-photon resonant three-photon ionization of cesium via np states is undetectable. Application of an electric field mixes nearby nd and ns levels, thereby inducing excitation and subsequent ionization. Signal due to two-photon excitation of ns levels in field-free experiments is weak due to their small photoionization cross section. An electric field mixes nearby np levels which again allows detectable photo-ionization signal. For both ns and np states the ''field induced'' MPI signal increases as the square of the electric field for a given principal quantum number and increases rapidly with n for a given field strength

  6. Resonance ionization spectroscopy in dysprosium

    Energy Technology Data Exchange (ETDEWEB)

    Studer, D., E-mail: dstuder@uni-mainz.de; Dyrauf, P.; Naubereit, P.; Heinke, R.; Wendt, K. [Johannes Gutenberg-Universität Mainz, Institut für Physik (Germany)

    2017-11-15

    We report on resonance ionization spectroscopy (RIS) of high-lying energy levels in dysprosium. We developed efficient excitation schemes and re-determined the first ionization potential (IP) via analysis of Rydberg convergences. For this purpose both two- and three-step excitation ladders were investigated. An overall ionization efficiency of 25(4) % could be demonstrated in the RISIKO mass separator of Mainz University, using a three-step resonance ionization scheme. Moreover, an extensive analysis of the even-parity 6sns- and 6snd-Rydberg-series convergences, measured via two-step excitation was performed. To account for strong perturbations in the observed s-series, the approach of multichannel quantum defect theory (MQDT) was applied. Considering all individual series limits we extracted an IP-value of 47901.76(5) cm{sup −1}, which agrees with the current literature value of 47901.7(6) cm{sup −1}, but is one order of magnitude more precise.

  7. Ionizing radiation accidents. Data interpretation

    International Nuclear Information System (INIS)

    Cascon, Adriana S.

    2003-01-01

    After a general outlook of the biological effects at the cellular and molecular level, the somatic effects of the ionizing radiation are described. Argentine regulations and the ICRP recommendations on radiological protection of professionally exposed workers are also summarized. The paper includes practical advices for the physician that has to take care of an irradiated patient

  8. Atomic and molecular resonance ionization

    International Nuclear Information System (INIS)

    Botter, R.; Petit, A.

    1990-01-01

    Published in summary form only the paper recalls the principle of resonance photoionization, transition probability, selectivity and critical parameters. Examples of applications are briefly treated: Trace analysis by resonance ionization mass spectroscopy for detection of Fe in Zr F 4 for fabrication of optical fibers and laser isotopic separation of U 235 and Gd 157 [fr

  9. Natural sources of ionizing radiations

    International Nuclear Information System (INIS)

    Marej, A.N.

    1984-01-01

    Natural sources of ionizing radiations are described in detail. The sources are subdivided into sources of extraterrestrial origin (cosmic radiation) and sources of terrestrial origin. Data on the concentration of different nuclides in rocks, various soils, ground waters, atmospheric air, tissues of plants and animals, various food stuffs are presented. The content of natural radionuclides in environmental objects, related to human activities, is discussed

  10. Negative chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Smit, A.L.C.

    1979-01-01

    This thesis describes some aspects of Negative Chemical Ionization (NCI) mass spectrometry. The reasons for the growing interest in NCI are: (i) to extend the basic knowledge of negative ions and their reactions in the gas phase; (ii) to investigate whether or not this knowledge of negative ions can be used successfully to elucidate the structure of molecules by mass spectrometry. (Auth.)

  11. Multiphoton ionization of atomic cesium

    International Nuclear Information System (INIS)

    Compton, R.N.; Klots, C.E.; Stockdale, J.A.D.; Cooper, C.D.

    1984-01-01

    We describe experimental studies of resonantly enhanced multiphoton ionization (MPI) of cesium atoms in the presence and absence of an external electric field. In the zero-field studies, photoelectron angular distributions for one- and two-photon resonantly enhanced MPI are compared with the theory of Tang and Lambropoulos. Deviations of experiment from theory are attributed to hyperfine coupling effects in the resonant intermediate state. The agreement between theory and experiment is excellent. In the absence of an external electric field, signal due to two-photon resonant three-photon ionization of cesium via np states is undetectable. Application of an electric field mixes nearby nd and ns levels, thereby inducing excitation and subsequent ionization. Signal due to two-photon excitation of ns levels in field-free experiments is weak due to their small photoionization cross section. An electric field mixes nearby np levels which again allows detectable photoionization signal. For both ns and np states the field induced MPI signal increases as the square of the electric field for a given principal quantum number and increases rapidly with n for a given field strength. Finally, we note that the classical two-photon field-ionization threshold is lower for the case in which the laser polarization and the electric field are parallel than it is when they are perpendicular. 22 references, 11 figures

  12. Biopositive Effects of Ionizing Radiation?

    International Nuclear Information System (INIS)

    Broda, E.

    1972-01-01

    This paper was written for a talk given by E. Broda in Vienna for an event organised by the chemical physical society, the Austrian biochemical society and the Austrian biophysical society in December 1972. In this paper Broda analyses the question of biopositive effects of ionizing radiation. (nowak)

  13. Ionizing radiations: effects and sources

    International Nuclear Information System (INIS)

    Vignes, S.; Nenot, J.C.

    1978-01-01

    Having first mentioned the effects of ionizing radiations in cancerogenisis, pre-natal, and genetic fields, the authors present the different sources of radiations and estimate their respective contributions to the total irradiation dose. Their paper makes reference to the main elements of a report issued by the United Nations Scientific Committee in 1977 [fr

  14. Ionizing radiations, detection, dosimetry, spectrometry

    International Nuclear Information System (INIS)

    Blanc, D.

    1997-10-01

    A few works in French language are devoted to the detection of radiations. The purpose of this book is to fill a gap.The five first chapters are devoted to the properties of ionizing radiations (x rays, gamma rays, leptons, hadrons, nuclei) and to their interactions with matter. The way of classification of detectors is delicate and is studied in the chapter six. In the chapter seven are studied the statistics laws for counting and the spectrometry of particles is treated. The chapters eight to thirteen study the problems of ionization: charges transport in a gas, ionization chambers (theory of Boag), counters and proportional chambers, counters with 'streamers', chambers with derive, spark detectors, ionization chambers in liquid medium, Geiger-Mueller counters. The use of a luminous signal is the object of the chapters 14 to 16: conversion of a luminous signal in an electric signal, scintillators, use of the Cerenkov radiation. Then, we find the neutron detection with the chapter seventeen and the dosimetry of particles in the chapter eighteen. This book does not pretend to answer to specialists questions but can be useful to physicians, engineers or physics teachers. (N.C.)

  15. On the Saha Ionization Equation

    Indian Academy of Sciences (India)

    Abstract. We revisit the Saha Ionization Equation in order to highlightthe rich interdisciplinary content of the equation thatstraddles distinct areas of spectroscopy, thermodynamics andchemical reactions. In a self-contained discussion, relegatedto an appendix, we delve further into the hidden message ofthe equation in terms ...

  16. A liquid ionization chamber using tetramethylsilane

    International Nuclear Information System (INIS)

    Engler, J.; Keim, H.

    1983-12-01

    First results with a liquid ionization chamber using tetramethylsilane (TMS) are presented. A stack of iron plates was tested with cosmic ray muons and the charge output for minimum ionizing particles was measured. (orig.) [de

  17. UV Ionizer for Neutral Wind Mass Spectrometers

    Data.gov (United States)

    National Aeronautics and Space Administration — Current neutral particle instrumentation relies on hot cathode filaments or an electron gun for ionizing the target medium.  These ionization sources represent a...

  18. Determination of ribavirin in human serum using liquid chromatography tandem mass spectrometry

    NARCIS (Netherlands)

    van der Lijke, H.; Alffenaar, J.-W. C.; Kok, W.Th.; Greijdanus, B.; Uges, D.R.A.

    2012-01-01

    A method has been developed for the determination of ribavirin in human serum for therapeutic drug monitoring purposes, using liquid chromatography electrospray ionization mass spectrometry. Separation was obtained with a mobile phase gradient starting and ending in 100% aqueous conditions using a

  19. In vitro induction of tuber formation with special reference to ...

    African Journals Online (AJOL)

    login

    2013-05-15

    May 15, 2013 ... performance liquid chromatography (HPLC) and liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS). There was a ... medicinal herb having many therapeutic applications in. Ayurvedic, Unani .... The qualitative analysis was done on the basis of common ion peak available in the ...

  20. Content of oak moss allergens atranol and chloroatranol in perfumes and similar products

    DEFF Research Database (Denmark)

    Rastogi, Suresh Chandra; Bossi, Rossana; Johansen, Jeanne D

    2004-01-01

    available on the European market. In total, 31 products were analysed by liquid chromatography-electrospray ionization-tandemmass spectrometry (LC-ESI-MS-MS) for their contents of atranol and chloroatranol. The 2 substances were found in 87% (n = 27) of the products. The median concentration of atranol...

  1. PHOSPHOLIPIDS OF FIVE PSEUDOMONAD ARCHETYPES FOR DIFFERENT TOLUENE DEGRADATION PATHWAYS

    Science.gov (United States)

    Liquid chromatography/electrospray ionization/mass spectrometry (LC/ESI/MS) was used to determine phospholipid profiles for five reference pseudomonad strains harboring distinct toluene catabolic pathways: Pseudomonas putida mt-2, Pseudomonas putida F1, Burkholderia cepacia G4, B...

  2. Components of non-anthocyanin phenolic compounds in wines of ...

    African Journals Online (AJOL)

    Zuo Shan Yi, Zuo Shan Er, Shuang Hong, Shuang You and Shuang Feng) of Vitis amurensis and two hybrid cultivars (Zuo Hong Yi and Zuo You Hong) were examined by high-performance liquid chromatography/electrospray ionization tandem ...

  3. Automatic system for evaluation of ionizing field

    International Nuclear Information System (INIS)

    Pimenta, N.L.; Calil, S.J.

    1992-01-01

    A three-dimensional cartesian manipulator for evaluating the ionizing field and able to position a ionization chamber in any point of the space is developed. The control system is made using a IBM microcomputer. The system aimed the study of isodose curves from ionizing sources, verifying the performance of radiotherapeutic equipment. (C.G.C.)

  4. Progress on untargeted effects of ionizing irradiation

    International Nuclear Information System (INIS)

    Liu Jing; Chen Jihong; Li Wenjian

    2010-01-01

    The side effect of ionizing irradiation has been paid more attention with its widely using in tumor treating and mutation breeding. In recent years, untargeted effects induced by ionizing irradiation have become a hotspot of radiobiology. Here, according to reported results, we reviewed the types (genomic instability, bystander effect and adaptive response) and mechanisms of untargeted effects of ionizing irradiation in this paper. (authors)

  5. 29 CFR 1926.53 - Ionizing radiation.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Ionizing radiation. 1926.53 Section 1926.53 Labor... § 1926.53 Ionizing radiation. (a) In construction and related activities involving the use of sources of ionizing radiation, the pertinent provisions of the Nuclear Regulatory Commission's Standards for...

  6. 29 CFR 1910.1096 - Ionizing radiation.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 6 2010-07-01 2010-07-01 false Ionizing radiation. 1910.1096 Section 1910.1096 Labor... Ionizing radiation. (a) Definitions applicable to this section. (1) Radiation includes alpha rays, beta... the quantity of ionizing radiation absorbed, per unit of mass, by the body or by any portion of the...

  7. Ionizing radiation sources. Ionizing radiation interaction with matter

    International Nuclear Information System (INIS)

    Popits, R.

    1976-01-01

    Fundamentals of nuclear physics are reviewed under the headings: obtaining of X-rays and their properties; modes of radioactive decay of natural or man-made radionuclides; radioactive neutron sources; nuclear fission as basis for devising nuclear reactors and weapons; thermonuclear reactions; cosmic radiation. Basic aspects of ionizing radiation interactions with matter are considered with regard to charged particles, photon radiation, and neutrons. (A.B.)

  8. Electron-Impact Ionization and Dissociative Ionization of Biomolecules

    Science.gov (United States)

    Huo, Winifred M.; Chaban, Galina M.; Dateo, Christopher E.

    2006-01-01

    It is well recognized that secondary electrons play an important role in radiation damage to humans. Particularly important is the damage of DNA by electrons, potentially leading to mutagenesis. Molecular-level study of electron interaction with DNA provides information on the damage pathways and dominant mechanisms. Our study of electron-impact ionization of DNA fragments uses the improved binary-encounter dipole model and covers DNA bases, sugar phosphate backbone, and nucleotides. An additivity principle is observed. For example, the sum of the ionization cross sections of the separate deoxyribose and phosphate fragments is in close agreement with the C3(sup prime)- and C5 (sup prime)-deoxyribose-phospate cross sections, differing by less than 5%. Investigation of tandem double lesion initiated by electron-impact dissociative ionization of guanine, followed by proton reaction with the cytosine in the Watson-Crick pair, is currently being studied to see if tandem double lesion can be initiated by electron impact. Up to now only OH-induced tandem double lesion has been studied.

  9. Cell fusion by ionizing radiation

    International Nuclear Information System (INIS)

    Khair, M.B.

    1993-08-01

    The relevance and importance of cell fusion are illustrated by the notion that current interest in this phenomenon is shared by scientists in quite varied disciplines. The diversity of cellular membrane fusion phenomena could provoke one to think that there must be a multitude of mechanisms that can account for such diversity. But, in general, the mechanism for the fusion reaction itself could be very similar in many, or even all, cases. Cell fusion can be induced by several factors such as virus Sendai, polyethylene glycol, electric current and ionizing radiation. This article provides the reader with short view of recent progress in research on cell fusion and gives some explanations about fusion mechanisms. This study shows for the first time, the results of the cell fusion induced by ionizing radiations that we have obtained in our researches and the work performed by other groups. (author). 44 refs

  10. Laser ionization of molecular clusters

    International Nuclear Information System (INIS)

    Desai, S.; Feigerle, C.S.

    1995-01-01

    Multiphoton ionization coupled with mass spectrometry was used to investigate molecular cluster distributions. Three examples will be discussed in this presentation. First, in studies of neat nitric oxide clusters, (NO) m , an interesting odd-even intensity alternation was observed and will be discussed in terms of electron-pairing considerations. In a separate study, the binary clusters comprising nitric oxide and methane preferentially form a stoichiometric cluster made up of repeating units of (NO) 2 CH 4 . These presumably represent a particularly strongly bound open-quotes van der Waalsclose quotes subunit. Finally, in similar studies of neat carbon disulfide clusters, (CS 2 ) m , additional photon absorption after the two-photon ionization step stimulates a series of intracluster ion-molecular reactions leading to formation of S m + and (CS) m + polymers, as well as intermediate species such as S m + (CS 2 ). This molecular cluster analogue of open-quotes laser snowclose quotes will be described in detail

  11. Health effects of ionizing radiation

    International Nuclear Information System (INIS)

    Radford, E.P.

    1980-01-01

    This presentation is restricted to the health effects of low doses of ionizing radiation. In general, these cumulative exposures are well below 100 rem, or about 50 times background or less. The two effects of interest in this dose range are genetic mutations and cancer production. The genetic effects will not be discussed in detail. The chief reason for the rise in risk estimates for cancer is the longer follow-up of exposed populations

  12. Ionizing radiation perception by insects

    International Nuclear Information System (INIS)

    Campanhola, C.

    1980-04-01

    The proof of the existence of a perception for ionizing radiation by insects was aimed at, as well as the determination of its processing mechanism. It was tried also to check if such perception induces the insects to keep away from the radiation source, proving therefore a protection against the harms caused by ionizing radiation, or else the stimulus for such behaviour is similar to that caused by light radiations. 60 Co and 241 Am were used as gamma radiation sources, the 60 Co source of 0.435mCi and the 241 Am of 99.68mCi activity. Adult insects were used with the following treatments : exposure to 60 Co and 241 Am radiation and non-exposure (control). A total of approximately 50 insects per replication was released in the central region of an opaque white wooden barrier divided into 3 sections with the same area - 60.0 cm diameter and 7.5 cm height - covered with a nylon screen. 5 replications per treatment were made and the distribution of the insects was evaluated by photographs taken at 15, 30, 45, and 60 minutes after release. Sitophilus oryzae (l., 1763) and Ephestia cautella (Walker, 1864) showed some response to 241 Am gamma radiation, i.e. negative tactism. It was concluded that ionizing radiations can be detected by insects through direct visual stimulus or by visual stimulus reslting from interaction of radiation-Cerenkov radiation - with some other occular component with a refraction index greater than water. Also, the activity of the radioactive source with regard to perception for ionizing radiation, is of relevance in comparison with the energy of the radiation emitted by same, or in other words, what really matters is the radiation dose absorbed. (Author) [pt

  13. Biological effects of ionizing radiation

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Experiments with small animals, tissue cultures, and inanimate materials help with understanding the effects of ionizing radiation that occur at the molecular level and cause the gross effects observed in man. Topics covered in this chapter include the following: Radiolysis of Water; Radiolysis of Organic Compounds; Radiolysis in Cells; Radiation Exposure and Dose Units; Dose Response Curves; Radiation Effects in Animals; Factors Affecting Health Risks. 8 refs., 3 figs., 5 tabs

  14. Risks Associated with Ionizing Radiations

    International Nuclear Information System (INIS)

    Cascon, Adriana

    2009-01-01

    Medical use of ionizing radiations implies certain risks which are widely balanced by their diagnostic and therapeutic benefits. Nevertheless, knowledge about these risks and how to diagnose and prevent them minimizes their disadvantages and optimizes the quality and safety of the method. This article describes the aspects related to skin dose (nonstochastic effects), the importance of dose limit, the physiopathology of biological damage and, finally, the prevention measures. [es

  15. The dosimetry of ionizing radiation

    CERN Document Server

    1990-01-01

    A continuation of the treatise The Dosimetry of Ionizing Radiation, Volume III builds upon the foundations of Volumes I and II and the tradition of the preceeding treatise Radiation Dosimetry. Volume III contains three comprehensive chapters on the applications of radiation dosimetry in particular research and medical settings, a chapter on unique and useful detectors, and two chapters on Monte Carlo techniques and their applications.

  16. Ionization of H Rydberg atoms

    International Nuclear Information System (INIS)

    Hillermier, C.F.; Bluemental, R.; Smilansky, U.

    1991-07-01

    Concepts from the theory of transient chaos are applied to study the classical ionization process of one dimensional model of kicked hydrogen Rydberg atoms. The phase-space dynamics is represented by a mapping T which is proved to be hyperbolic. The fraction of atoms not ionized after time t, P B (t), decays asymptotically according to P B (t)∼t -α with α ∼ 1.65. The observed algebraic decay, which seems to contradict the hyperbolicity of T, is explained by (i) the symbolic dynamics of T consists of a countably infinite number of symbols and (ii) the invariant manifold of phase-space points which never ionize is an anomalously scaling fractal. Therefore, the one-dimensional kicked hydrogen atom provides a counterexample to the hypothesis that algebraic decay marks regular dynamics, whereas hyperbolic systems decay exponentially. The algebraic decay is reproduced by an analytically solvable diffusion model which predicts α = 3/2. Replacing zero-width δ-kicks by smooth finite-width pulses, the mapping T is no longer completely hyperbolic, and a subset of phase-space is regular. For this case we observe that P B (t) shows a transition between two power-law decays with α ∼ 1.65 for short times and α ∼ 2.1 for long times where the effect of the regular domain is felt. (author)

  17. Ionizing radiation and cancer prevention

    International Nuclear Information System (INIS)

    Hoel, D.G.

    1995-01-01

    Ionizing radiation long has been recognized as a cause of cancer. Among environmental cancer risks, radiation in unique in the variety of organs and tissues that it can affect. Numerous epidemiological studies with good dosimetry provide the basis for cancer risk estimation, including quantitative information derived from observed dose-response relationships. The amount of cancer attributable to ionizing radiation is difficult to estimate, but numbers such as 1 to 3% have been suggested. Some radiation-induced cancers attributable to ionizing radiation is difficult to estimate, but numbers such as 1 to 3% have been suggested. Some radiation-induced cancers attributable to naturally occurring exposures, such as cosmic and terrestrial radiation, are not preventable. The major natural radiation exposure, radon, can often be reduced, especially in the home, but not entirely eliminated. Medical use of radiation constitutes the other main category of exposure, radon, can often be reduced, especially in the home, but not entirely eliminated. Medical use of radiation constitutes the other main category of exposure; because of the importance of its benefits to one's health, the appropriate prevention strategy is to simply work to minimize exposures. 9 refs., 1 fig., 5 tabs

  18. Loss of ions in cavity ionization chambers

    International Nuclear Information System (INIS)

    Takata, N.; Tran, N.T.; Kim, E.; Marsoem, P.; Kurosawa, T.; Koyama, Y.

    2005-01-01

    Ion losses due to initial recombination, volume recombination, and back diffusion were each determined by measurements and calculations for different size cylindrical ionization chambers and spherical ionization chambers. By measuring signal currents from these ionization chambers irradiated with 60 Co gamma rays, two groups of ion losses were obtained. (Group 1) Ion loss due to initial recombination and diffusion, which changes proportionally to the inverse of the voltage applied to the ionization chambers; (and group 2) ion loss due to volume recombination, which changes proportionally to the inverse of the square of the applied voltage. The diffusion loss was obtained separately by computing electric field distributions in the ionization chambers. It was found that diffusion loss is larger than initial recombination loss for the cylindrical ionization chambers and vise versa for the spherical ionization chambers

  19. On the ionization of interstellar magnesium

    International Nuclear Information System (INIS)

    Gurzadyan, G.A.

    1977-01-01

    It has been shown that two concentric ionization zones of interstellar magnesium must exist around each star: internal, with a radius coinciding with that of the zone of hydrogen ionization Ssub(H); and external, with a radius greater than Ssub(H), by one order. Unlike interstellar hydrogen, interstellar magnesium is ionized throughout the Galaxy. It also transpires that the ionizing radiation of ordinary hot stars cannot provide for the observed high degree of ionization of interstellar magnesium. The discrepance can be eliminated by assuming the existence of circumstellar clouds or additional ionization sources of interstellar magnesium (X-ray background radiation, high-energy particles, etc.). Stars of the B5 and BO class play the main role in the formation of ionization zones of interstellar magnesium; the contribution of O class stars is negligible (<1%). (Auth.)

  20. Hygienic regulation of ionizing radiations

    International Nuclear Information System (INIS)

    Saurov, M.M.

    1984-01-01

    Modern state of the problem on hygienic regulation of ionizing radiations is considered. Concepts and principles of the regulation based on risk concept are presented according to ICRP 26 and 27. Two types of risk are designated: ''absolute'' and ''relative'' ones. The concept of acceptable risk on the basis of cost - benefit ratio is substantiated. Special attention is paid to the principle of accounting the complex of health signs, when determining radiation hazard. To determine the level of permissible risk and permissible dose to population the concept of ''inadmissibility of s-tatistically significant risk'' has been developed. Standards, regulating population doses in the USSR, which are valid nowadays, are considered

  1. Biological effects of ionizing radiation

    International Nuclear Information System (INIS)

    Heribanova, A.

    1995-01-01

    The basic principles and pathways of effects of ionizing radiation on living organisms and cells are outlined. The following topics are covered: effects of radiation on living matter (direct effects, radical or indirect effects, dual radiation action, and molecular biological theories); effects of radiation on cells and tissues (cell depletion, changes in the cytogenetic information, reparation mechanisms), dose-response relationship (deterministic effects, stochastic effects), and the effects of radiation on man (acute radiation sickness, acute local changes, fetus injuries, non-tumorous late injuries, malignant tumors, genetic changes). (P.A.). 3 tabs., 2 figs., 5 refs

  2. XUV ionization of aligned molecules

    Energy Technology Data Exchange (ETDEWEB)

    Kelkensberg, F.; Siu, W.; Gademann, G. [FOM Institute AMOLF, Science Park 104, NL-1098 XG Amsterdam (Netherlands); Rouzee, A.; Vrakking, M. J. J. [FOM Institute AMOLF, Science Park 104, NL-1098 XG Amsterdam (Netherlands); Max-Born-Institut, Max-Born Strasse 2A, D-12489 Berlin (Germany); Johnsson, P. [FOM Institute AMOLF, Science Park 104, NL-1098 XG Amsterdam (Netherlands); Department of Physics, Lund University, Post Office Box 118, SE-221 00 Lund (Sweden); Lucchini, M. [Department of Physics, Politecnico di Milano, Istituto di Fotonica e Nanotecnologie CNR-IFN, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Lucchese, R. R. [Department of Chemistry, Texas A and M University, College Station, Texas 77843-3255 (United States)

    2011-11-15

    New extreme-ultraviolet (XUV) light sources such as high-order-harmonic generation (HHG) and free-electron lasers (FELs), combined with laser-induced alignment techniques, enable novel methods for making molecular movies based on measuring molecular frame photoelectron angular distributions. Experiments are presented where CO{sub 2} molecules were impulsively aligned using a near-infrared laser and ionized using femtosecond XUV pulses obtained by HHG. Measured electron angular distributions reveal contributions from four orbitals and the onset of the influence of the molecular structure.

  3. XUV ionization of aligned molecules

    International Nuclear Information System (INIS)

    Kelkensberg, F.; Siu, W.; Gademann, G.; Rouzee, A.; Vrakking, M. J. J.; Johnsson, P.; Lucchini, M.; Lucchese, R. R.

    2011-01-01

    New extreme-ultraviolet (XUV) light sources such as high-order-harmonic generation (HHG) and free-electron lasers (FELs), combined with laser-induced alignment techniques, enable novel methods for making molecular movies based on measuring molecular frame photoelectron angular distributions. Experiments are presented where CO 2 molecules were impulsively aligned using a near-infrared laser and ionized using femtosecond XUV pulses obtained by HHG. Measured electron angular distributions reveal contributions from four orbitals and the onset of the influence of the molecular structure.

  4. Space Flight Ionizing Radiation Environments

    Science.gov (United States)

    Koontz, Steve

    2017-01-01

    The space-flight ionizing radiation (IR) environment is dominated by very high-kinetic energy-charged particles with relatively smaller contributions from X-rays and gamma rays. The Earth's surface IR environment is not dominated by the natural radioisotope decay processes. Dr. Steven Koontz's lecture will provide a solid foundation in the basic engineering physics of space radiation environments, beginning with the space radiation environment on the International Space Station and moving outward through the Van Allen belts to cislunar space. The benefits and limitations of radiation shielding materials will also be summarized.

  5. Advanced Thin Ionization Calorimeter (ATIC)

    Science.gov (United States)

    Wefel, John P.

    1998-01-01

    This is the final report for NASA grant NAGW-4577, "Advanced Thin Ionization Calorimeter (ATIC)". This grant covered a joint project between LSU and the University of Maryland for a Concept Study of a new type of fully active calorimeter to be used to measure the energy spectra of very high energy cosmic rays, particularly Hydrogen and Helium, to beyond 1014 eV. This very high energy region has been studied with emulsion chamber techniques, but never investigated with electronic calorimeters. Technology had advanced to the point that a fully active calorimeter based upon Bismuth Germanate (BGO) scintillating crystals appeared feasible for balloon flight (and eventually space) experiments.

  6. Effects of ionizing radiation on vitamins

    International Nuclear Information System (INIS)

    Thayer, D.W.; Fox, J.B. Jr.; Lakritz, L.

    1991-01-01

    Vitamins are known to be sensitive to the effects of ionizing radiation. Since most foods contain a large proportion of water, the most probable reaction of the ionizing radiation would be with water; and as vitamins are present in very small amounts compared with other substances in the food they will be affected indirectly by the radiation. This chapter discusses the effect of ionizing radiation on water soluble vitamins and fat soluble vitamins. (author)

  7. Biological effects of ionizing radiation

    International Nuclear Information System (INIS)

    Gisone, Pablo; Perez, Maria R.

    2001-01-01

    It has been emphasised the importance of DNA as the main target for ionizing radiation, that can induce damage by its direct action on this molecule or by an indirect effect mediated by free-radicals generated by water radiolysis. Biological effects of ionizing radiation are influenced not only by the dose but also by the dose-rate and the radiation quality. Radiation induced damage, mainly DNA single and double strand breaks, is detected by molecular sensors which in turn trigger signalling cascades leading to cell cycle arrest to allow DNA repair or programmed cell death (apoptosis). Those effects related with cell death, named deterministic, exhibits a dose-threshold below which they are not observed. Acute radiation syndrome and radiological burns are examples of this kind of effects. Other radiation induced effects, called stochastic, are the consequence of cell transformation and do not exhibit a dose-threshold. This is the case of cancer induction and hereditary effects. The aim of this presentation is briefly describe the main aspects of deterministic and stochastic effects from the point of view of radiobiology and radio pathology. (author)

  8. Chemical protection against ionizing radiation

    International Nuclear Information System (INIS)

    Livesey, J.C.; Reed, D.J.

    1987-01-01

    Over 40 years have passed since the research of the Manhattan Project suggested the possibility of chemical protection against ionizing radiation. During that time, much has been learned about the nature of radiation-induced injury and the factors governing the expression of that injury. Thousands of compounds have been tested for radioprotective efficacy, and numerous theories have been proposed to account for these actions. The literature on chemical radioprotection is large. In this article, the authors consider several of the mechanisms by which chemicals may protect against radiation injury. They have chosen to accent this view of radioprotector research as opposed to that research geared toward developing specific molecules as protective agents because they feel that such an approach is more beneficial in stimulating research of general applicability. This paper describes the matrix of biological factors upon which an exogenous radioprotector is superimposed, and examines evidence for and against various mechanisms by which these agents may protect biological systems against ionizing radiation. It concludes with a brief outlook for research in chemical radioprotection

  9. NMR Metabolomics in Ionizing Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jian Z.; Xiao, Xiongjie; Hu, Mary Y.

    2016-09-08

    Ionizing radiation is an invisible threat that cannot be seen, touched or smelled and exist either as particles or waves. Particle radiation can take the form of alpha, beta or neutrons, as well as high energy space particle radiation such as high energy iron, carbon and proton radiation, etc. (1) Non-particle radiation includes gamma- and x-rays. Publically, there is a growing concern about the adverse health effects due to ionizing radiation mainly because of the following facts. (a) The X-ray diagnostic images are taken routinely on patients. Even though the overall dosage from a single X-ray image such as a chest X-ray scan or a CT scan, also called X-ray computed tomography (X-ray CT), is low, repeated usage can cause serious health consequences, in particular with the possibility of developing cancer (2, 3). (b) Human space exploration has gone beyond moon and is planning to send human to the orbit of Mars by the mid-2030s. And a landing on Mars will follow.

  10. Ionizing radiations in food industry

    International Nuclear Information System (INIS)

    Adamo, M.; Tata, A.

    1999-01-01

    Foodstuffs treatment by ionization is able to produce both a shelf-life extension and/or a food borne diseases control through the pathogenic population reduction/elimination. The main process goal is to ensure the hygienic quality and the wholesomeness of products to be marketed, in order to limit food borne diseases originated mainly through the cross contamination process. In fact several products may contain pathogenic agents or bacteria (e.g. Salmonella and Campylbacter in poultry meat), whose associated pathologies are world-wide increasing. At present, over 40 countries provide clearances for the treatment of about 45 different types of foodstuffs and in over 20 of them the ionizing process is already industrially utilized for spices, poultry, shrimps and vegetables. As it refers to process economic aspects, market researches have shown cost figures ranging from few tens to some hundreds Lit/kg, depending on the dose to products. The costs are competitive with alternative treatments, beyond the recovery of economic productivity reduction caused by food borne diseases

  11. Epigenetic effects of ionizing radiation

    International Nuclear Information System (INIS)

    EI-Naggar, A.M.

    2007-01-01

    Data generated during the last three decades provide evidence of Epigenetic Effects that ave-induced by ionizing radiation, particularly those of high LET values, and low level dose exposures. Epigenesist is defined as the stepwise process by which genetic information, as modified by environmental influences, is translated into the substance and behavior of cells, tissues, organism.The epigenetic effects cited in the literature are essentially classified into fine types depending on the type and nature of the effect induced.The most accepted postulation, for the occurrence of these epigenetic effects, is a radiation induced bio electric disturbances in the environment of the non-irradiated cellular volume. This will trigger signals that will induce effects in the unirradiated cells.The epigenetic effects referenced in the literature up to date are five types; namely, Genomic Instability, Bystander. Effects, Clastogenic Plasma Factors,, Abscopal Effects, and Tran generational Effects.The demonstration of Epigenetic Effects associated with exposure to ionizing radiation indicates the need to re- examine the concept of radiation dose and target size. Also an improved understanding of qualifiring and quantifying radiation risk estimates may be attained. Also, a more logical means to understand the underlying mechanisms of radiation induced carcinogenic transformation of cells

  12. K-shell ionization by antiprotons

    International Nuclear Information System (INIS)

    Mehler, G.; Mueller, B.; Greiner, W.; Soff, G.

    1987-01-01

    We present first calculations for the impact parameter dependence of K-shell ionization rates in anti pCu and in anti pAg collisions at various projectile energies. We show that the effect of the attractive Coulomb potential on the Rutherford trajectory and the anti-binding effect caused by the negative charge of the antiproton result in a considerable increase of the ionization probability. Total ionization cross-sections for proton and antiproton projectiles are compared with each other and with experimental ionization cross-sections for protons. (orig.)

  13. Regulatory control of ionizing radiations in Ecuador

    International Nuclear Information System (INIS)

    Benitez, Manuel

    1996-03-01

    This document deals with legal aspects for controlling ionizing radiations, radiological safety regulations and objectives, scopes and features of the national radioprotection planning in Ecuador. (The author)

  14. Ionization probes of molecular structure and chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, P.M. [State Univ. of New York, Stony Brook (United States)

    1993-12-01

    Various photoionization processes provide very sensitive probes for the detection and understanding of the spectra of molecules relevant to combustion processes. The detection of ionization can be selective by using resonant multiphoton ionization or by exploiting the fact that different molecules have different sets of ionization potentials. Therefore, the structure and dynamics of individual molecules can be studied even in a mixed sample. The authors are continuing to develop methods for the selective spectroscopic detection of molecules by ionization, and to use these methods for the study of some molecules of combustion interest.

  15. Ionization versus indirect effects of ionizing radiation on cellular DNA

    International Nuclear Information System (INIS)

    Cadet, Jean; Ravanat, Jean-Luc; Douki, Thierry

    2012-01-01

    Emphasis has been placed in the last decade on the elucidation of the main degradation pathways of isolated DNA mediated by hydroxyl radical (OH) and one-electron oxidation reactions as the result of indirect and direct effects of ionizing radiation respectively. This has led to the isolation and characterization of about 100 oxidized purine and pyrimidine nucleosides if hydroperoxide precursors and diastereomers are included. However, far less information is available on the mechanisms of radiation-induced degradation of bases in cellular DNA mostly due partly to analytical difficulties. It may be reminded that the measurement of oxidized nucleosides and bases in nuclear DNA is still a challenging issue which until recently has been hampered by the use of inappropriate methods such as the GC-MS that have led to overestimated values of the lesions by factors varying between two and three orders of magnitude. At the present, using the accurate and sensitive HPLC/MS/MS assay, 11 single modified nucleosides and bases were found to be generated in cellular DNA upon exposure to gamma rays and heavy ions. This validates several of the OH-mediated oxidation pathways of thymine, guanine and adenine that were previously inferred from model studies. The concomitant decrease in the yields of oxidized bases with the increase in the LET of heavy ions is accounted for by the preponderance of indirect effects in the damaging action of ionizing radiation on DNA. Further evidence for the major role played by .OH was provided by the results of exposure of cells to high intensity 266 nm laser pulses. Under these conditions 8-oxo-7,8-dihydroguanine is mostly produced by biphotonic ionization of DNA nucleobases and subsequent hole migration to guanine bases. It is likely that some of the oxidized bases that have been isolated as single lesions are in fact involved in clustered damage. Interestingly it was recently shown that a single oxidation hit is capable of generating complex

  16. Ionizing radiation and non-ionizing radiation in educational environment

    International Nuclear Information System (INIS)

    Matsuzawa, Takao; Otsubo, Tomonobu; Ikke, Satoshi; Taguchi, Noriko; Takeda, Rie

    2005-01-01

    By chance, we measured gamma dose rates in our school, and around the JCO Tokai Plant during the criticality on September 30 in 1999, with our GM survey meter. At that time, we made sure to estimate the position of criticality reaction (source point), and the source intensity of criticality reaction, with our own data, measured along the public roads, route 6 and local road 62. The intensity of gamma dose rates along the road was analyzed as Lorentz functions. At the time, there were no environmental radiation data about the criticality accident, or all the data, especially radioactivity and dose rates around the JCO Tokai Plant, was closed to the public. Recently, we are interested in the intensity of non-ionizing radiation, especially extremely low frequency (ELF) magnetic field, and electric field, in our environment. We adopted the same method to analyze the source position and source intensity of an ELF magnetic field and electric behind a wall. (author)

  17. Heating and ionization in MHD shock waves propagating into partially ionized plasma

    International Nuclear Information System (INIS)

    Bighel, L.; Collins, A.R.; Cramer, N.F.; Watson-Munro, C.N.

    1975-09-01

    A model of the structure of MHD switch-on shocks propagating in a partially ionized plasma, in which the primary dissipation mechanism is friction between ions and neutrals, is here compared favourably with experimental results. Four degrees of upstream ionization were studied, ranging from almost complete to very small ionization. (author)

  18. Electron ionization and the Compton effect in double ionization of helium

    International Nuclear Information System (INIS)

    Samson, J.

    1994-01-01

    The author discusses ionization phenomena in helium, both photoionization and electron ionization. In particular he compares double ionization cross sections with total cross sections, as a function of electron energy, and photon energy. Data is discussed over the energy range up to 10 keV

  19. Current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization

    International Nuclear Information System (INIS)

    Stoyanov, D G

    2007-01-01

    The balances of particles and charges in the volume of parallel-plane ionization chamber are considered. Differential equations describing the distribution of current densities in the chamber volume are obtained. As a result of the differential equations solution an analytical form of the current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization in the volume is obtained

  20. Current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization

    Energy Technology Data Exchange (ETDEWEB)

    Stoyanov, D G [Faculty of Engineering and Pedagogy in Sliven, Technical University of Sofia, 59, Bourgasko Shaussee Blvd, 8800 Sliven (Bulgaria)

    2007-08-15

    The balances of particles and charges in the volume of parallel-plane ionization chamber are considered. Differential equations describing the distribution of current densities in the chamber volume are obtained. As a result of the differential equations solution an analytical form of the current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization in the volume is obtained.

  1. Heating and ionization in MHD shock wave propagating into partially ionized plasma

    International Nuclear Information System (INIS)

    Bighel, L.; Collins, A.R.; Cramer, N.F.; Watson-Munro, C.N.

    1975-09-01

    A model of the structure of MHD switch-on shocks propagating in a partially ionized plasma, in which the primary dissipation mechanism is friction between ions and neutrals, is here compared favourably with experimental results. Four degrees of upstream ionization were studied, ranging from almost complete to very small ionization. (author)

  2. Social trust and ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Meadd, E. [Faculty of Environmental Studies, York University, Toronto, Ontario (Canada)

    2002-07-01

    The linkages that exist between the environmental risks associated with nuclear energy production (both perceived and real) and the myriad of social and political issues and processes that influence social trust are a current issue in literature, but are not well explored, particularly for the Canadian context. This paper will examine one particular issue and its relationship with social trust: ionizing radiation and public health. Social trust is defined for this paper as including interpersonal trust, but having a much broader focus, extending to public trust in governments, institutions, corporations, and the power elite, and across whole societies. Of particular interest for the nuclear energy issue is how waning social trust may impact the functioning of democratic decision-making processes, particularly those associated with the siting of waste facilities. Social trust is a central issue in the management of environmental risks, particularly those related to high technology; its absence is seen as a major cause of intractable conflict in decisions related to nuclear power generation and waste disposal. Understanding the dynamics of social trust is important if a resolution is to be found to the nuclear waste management debate in Canada, that is, one that involves broad public, or social, support. For instance, what factors cause distrust to emerge, and when distrust emerges, what authorities do members of affected communities seek out for information and support? This paper begins to examine social trust in relation to human health and ionizing radiation, particularly low dose radiation from radioactive wastes resulting from uranium and radium processing activities in Port Hope, Ontario. These activities date back to the 1930s and are of great concern to community members. This paper looks at some of the roots of public concern, for example, scientific uncertainty around whether or not human health is compromised by exposure to low dose ionizing radiation

  3. Social trust and ionizing radiation

    International Nuclear Information System (INIS)

    Meadd, E.

    2002-01-01

    The linkages that exist between the environmental risks associated with nuclear energy production (both perceived and real) and the myriad of social and political issues and processes that influence social trust are a current issue in literature, but are not well explored, particularly for the Canadian context. This paper will examine one particular issue and its relationship with social trust: ionizing radiation and public health. Social trust is defined for this paper as including interpersonal trust, but having a much broader focus, extending to public trust in governments, institutions, corporations, and the power elite, and across whole societies. Of particular interest for the nuclear energy issue is how waning social trust may impact the functioning of democratic decision-making processes, particularly those associated with the siting of waste facilities. Social trust is a central issue in the management of environmental risks, particularly those related to high technology; its absence is seen as a major cause of intractable conflict in decisions related to nuclear power generation and waste disposal. Understanding the dynamics of social trust is important if a resolution is to be found to the nuclear waste management debate in Canada, that is, one that involves broad public, or social, support. For instance, what factors cause distrust to emerge, and when distrust emerges, what authorities do members of affected communities seek out for information and support? This paper begins to examine social trust in relation to human health and ionizing radiation, particularly low dose radiation from radioactive wastes resulting from uranium and radium processing activities in Port Hope, Ontario. These activities date back to the 1930s and are of great concern to community members. This paper looks at some of the roots of public concern, for example, scientific uncertainty around whether or not human health is compromised by exposure to low dose ionizing radiation

  4. Ionization efficiency calculations for cavity thermoionization ion source

    International Nuclear Information System (INIS)

    Turek, M.; Pyszniak, K.; Drozdziel, A.; Sielanko, J.; Maczka, D.; Yuskevich, Yu.V.; Vaganov, Yu.A.

    2009-01-01

    The numerical model of ionization in a thermoionization ion source is presented. The review of ion source ionization efficiency calculation results for various kinds of extraction field is given. The dependence of ionization efficiency on working parameters like ionizer length and extraction voltage is discussed. Numerical simulations results are compared to theoretical predictions obtained from a simplified ionization model

  5. Ionizing radiation and water reuse

    International Nuclear Information System (INIS)

    Borrely, Sueli Ivone; Sampa, Maria Helena de Oliveira; Oikawa, Hiroshi; Silveira, Carlos Gaia da; Duarte, Celina Lopes; Cherbakian, Eloisa Helena

    2002-01-01

    The aim of the present paper is to point out the possibility of including ionizing radiation for wastewater treatment and reuse. Radiation processing is an efficient technology which can be useful for water reuse once the process can reduce not only the biological contamination but also organic substances, promoting an important acute toxicity removal from aquatic resources. Final secondary effluents from three different wastewater treatment plant were submitted to electron beam radiation and the process efficacy was evaluated. Concerning disinfection, relatively low radiation doses (2,0 - 4,0 kGy) accounted for 4 to 6 cycle log reduction for total coliforms. When radiation was applied for general wastewater improvement related to the chemical contamination, radiation process reduced from 78% up to 100% the total acute toxicity, measured for crustaceans, D. similis, and for V. fiscehri bacteria. (author)

  6. Ionization cooling ring for muons

    Directory of Open Access Journals (Sweden)

    R. Palmer

    2005-06-01

    Full Text Available Practical ionization cooling rings could lead to lower cost or improved performance in neutrino factory or muon collider designs. The ring modeled here uses realistic three-dimensional fields. The performance of the ring compares favorably with the linear cooling channel used in the second U.S. Neutrino Factory Study. The normalized 6D emittance of an ideal ring is decreased by a factor of approximately 240, compared with a factor of only 15 for the linear channel. We also examine such real-world effects as windows on the absorbers and rf cavities and leaving empty lattice cells for injection and extraction. For realistic conditions the ring decreases the normalized 6D emittance by a factor of 49.

  7. Tunneling Ionization of Diatomic Molecules

    DEFF Research Database (Denmark)

    Svensmark, Jens Søren Sieg

    2016-01-01

    When a molecule is subject to a strong laser field, there is a probability that an electron can escape, even though the electrons are bound by a large potential barrier. This is possible because electrons are quantum mechanical in nature, and they are therefore able to tunnel through potential...... barriers, an ability classical particles do not possess. Tunnelling is a fundamental quantum mechanical process, a process that is distinctly non-classical, so solving this tunnelling problem is not only relevant for molecular physics, but also for quantum theory in general. In this dissertation the theory...... of tunneling ionizaion of molecules is presented and the results of numerical calculations are shown. One perhaps surprising result is, that the frequently used Born-Oppenheimer approximation breaks down for weak fields when describing tunneling ionization. An analytic theory applicable in the weak-field limit...

  8. Device for detecting ionizing radiation

    International Nuclear Information System (INIS)

    Anatychuk, L.I.; Kharitonov, J.P.; Kusniruk, V.F.; Meir, V.A.; Melnik, A.P.; Ponomarev, V.S.; Skakodub, V.A.; Sokolov, A.D.; Subbotin, V.G.; Zhukovsky, A.N.

    1980-01-01

    The present invention relates to ionizing radiation sensors, and , more particularly, to semiconductor spectrometers with thermoelectric cooling, and can most advantageously be used in mineral raw material exploration and evaluation under field conditions. The spectrometer comprises a vacuum chamber with an entrance window for passing the radiation therethrough. The vacuum chamber accommodates a thermoelectric cooler formed by a set of peltier elements. A heat conducting plate is mounted on the cold side of the thermoelectric cooler, and its hot side is provided with a radiator. Mounted on the heat conducting plate are sets of peltier elements, integral with the thermoelectric cooler and independent of one another. The peltier elements of these sets are stacked so as to develop the minimum temperature conditions on one set carrying a semiconductor detector and to provide the maximum refrigeration capacity conditions on the other set provided with the field-effect transistor mounted thereon

  9. Sodium ionization detector and sensor

    International Nuclear Information System (INIS)

    Hrizo, J.; Bauerle, J.E.

    1979-01-01

    Work conducted on a basic technology development effort with the Westinghouse Sodium Ionization Detector (SID) sensor is reported. Included are results obtained for three task areas: (1) On-line operational response testing - in-situ calibration techniques; (2) Performance-reliability characteristics of aged filaments; and (3) Evaluation of chemical interference effects. The results showed that a calibrator filament coated with a sodium compound, when activated, does supply the necessary sodium atoms to provide a valid operational in-situ test. The life time of new Cr 2 0 3 -protected SID sensor filaments can be extended by operating at a reduced temperature. However, there also is a reduction in the sensitivity. Non-sodium species, such as products from a smoldering fire and organic aerosols, produce an interference response from the sensor comparable to a typical sodium response

  10. Ionization by a pulsed plasma surface water

    International Nuclear Information System (INIS)

    Bloyet, E.; Leprince, P.; Marec, J.; Llamas Blasco, M.

    1981-01-01

    The ionization mechanism is studied of a pulsed surface wave generating a microwave discharge. When the plasma is dominated by collisions, it is found that the velocity of the ionization front depends on the ponderomotive force due to the field gradient in the front. (orig.)

  11. An ionization chamber with magnetic levitated electrodes

    CERN Document Server

    Kawaguchi, T

    1999-01-01

    A new type of ionization chamber which has magnetically levitated electrodes has been developed. The electrodes are supplied voltages for the repelling of ions by a battery which is also levitated with the electrodes. The characteristics of this ionization chamber are investigated in this paper.

  12. Basic symbol for ionizing radiations (second revision)

    International Nuclear Information System (INIS)

    1992-01-01

    Includes a detailed description of basic symbol for ionizing radiations to be used to prevent about the presence, or possibility of presence, of ionizing radiations (X-ray, gamma radiation, particles, electrons, neutrons and protons), as well as to identify radioactive devices and materials

  13. Gas ionization by focused laser beams

    International Nuclear Information System (INIS)

    Brito, A.L. de.

    1984-01-01

    It is shown that the effect of line broadening by focusing may considerably contribute to the observed laser-induced ionization of gases when the ionization energy of the gas molecules is well above the mean photon energy of the laser radiation. (Author) [pt

  14. A Versatile Integrated Ambient Ionization Source Platform

    Science.gov (United States)

    Ai, Wanpeng; Nie, Honggang; Song, Shiyao; Liu, Xiaoyun; Bai, Yu; Liu, Huwei

    2018-04-01

    The pursuit of high-throughput sample analysis from complex matrix demands development of multiple ionization techniques with complementary specialties. A versatile integrated ambient ionization source (iAmIS) platform is proposed in this work, based on the idea of integrating multiple functions, enhancing the efficiency of current ionization techniques, extending the applications, and decreasing the cost of the instrument. The design of the iAmIS platform combines flowing atmospheric pressure afterglow (FAPA) source/direct analysis in real time (DART), dielectric barrier discharge ionization (DBDI)/low-temperature plasma (LTP), desorption electrospray ionization (DESI), and laser desorption (LD) technique. All individual and combined ionization modes can be easily attained by modulating parameters. In particular, the FAPA/DART&DESI mode can realize the detection of polar and nonpolar compounds at the same time with two different ionization mechanisms: proton transfer and charge transfer. The introduction of LD contributes to the mass spectrometry imaging and the surface-assisted laser desorption (SALDI) under ambient condition. Compared with other individual or multi-mode ion source, the iAmIS platform provides the flexibility of choosing different ionization modes, broadens the scope of the analyte detection, and facilitates the analysis of complex samples. [Figure not available: see fulltext.

  15. Neutron accelerator tube having improved ionization section

    International Nuclear Information System (INIS)

    Givens, W.W.

    1982-01-01

    A neutron accelerator tube is described having a target section, an ionization section, and a replenisher section for supplying accelerator gas to the ionization section. The ionization section is located between the target and the replenisher section and includes an ionization chamber adapted to receive accelerator gas from the replenisher section. The ionization section further includes spaced cathodes having opposed active surfaces exposed to the interior of the ionization chamber. An anode is located intermediate the cathodes whereby in response to an applied positive voltage, electrons created by field emission are transmitted between the opposed active surfaces of the cathodes and produce the emission of secondary electrons. The active surface of at least one of the cathodes is formulated of a material having a secondary electron emission factor of at least one cathode member located in the tube adjacent to th replenisher section may have a protuberant portion extending axially into the ionization chamber. The other cathode spaced from the first cathode member in the direction of the target has an aperture therein along the axis of the protuberant portion. An annular magnet extends around the exterior of the ionization chamber and envelops the anode member. Means are provided to establish a high permeability magnetic flux path extending outwardly from the opposed poles from the magnet to the active surfaces of the cathode members

  16. Bystander Effects of Ionizing Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Little, John B. [Harvard T.H. Chan School of Public Health, Boston, MA (United States). Dept. of Genetics and Complex Diseases

    2017-01-17

    The objectives of this grant renewal are to provide administrative support and travel funds to allow the continued participation of the principal investigator (Dr. John B. Little) as an advisor to research initiated by several research fellows from his laboratory. The actual research will be carried out under the direction of Dr. Hatsumi Nagasawa with the collaboration of Dr. Joel Bedford at the Colorado State University, and by Drs. Edouard Azzam and Sonia de Toledo at the University of Medicine and Dentistry of New Jersey. Dr. Little will advise on the planning of experiments and development of experimental protocols, the analysis of data, and the preparation of manuscripts for publication. The Specific Aims for several of the planned experiments include: 1) to extend studies of the role of recombinational repair in the bystander effect by examining other genes in this pathway and cell lines deficient in excision repair; 2) to continue studies to determine the nature of the damage signal transmitted to bystander cells including the expression of several connexins in the bystander response, and the extent to which the enhanced oxidative metabolism observed in bystander cells may relate to the nature of the transmitted bystander signal; 3) to utilize a genome-wide approach to examine the genetic basis for the hypersensitivity to ionization we have observed in unaffected parents of patients with hereditary retinoblastoma, as well as from a group of apparently normal individuals that show similar radiosensitivity; 4) to complete studies concerning the induction of high frequencies of cells with massive chromosome damage in clonal derivatives of p53 and p21 knockout mouse cell lines; in particular to examine the role of telomere changes in this phenomenon. Overall, the results of these studies should enhance our understanding of the risk of low-dose exposures to ionizing radiation, including human populations to residential radon as well as occupational exposures.

  17. Bystander Effects of Ionizing Radiation

    International Nuclear Information System (INIS)

    Little, John B.

    2017-01-01

    The objectives of this grant renewal are to provide administrative support and travel funds to allow the continued participation of the principal investigator (Dr. John B. Little) as an advisor to research initiated by several research fellows from his laboratory. The actual research will be carried out under the direction of Dr. Hatsumi Nagasawa with the collaboration of Dr. Joel Bedford at the Colorado State University, and by Drs. Edouard Azzam and Sonia de Toledo at the University of Medicine and Dentistry of New Jersey. Dr. Little will advise on the planning of experiments and development of experimental protocols, the analysis of data, and the preparation of manuscripts for publication. The Specific Aims for several of the planned experiments include: 1) to extend studies of the role of recombinational repair in the bystander effect by examining other genes in this pathway and cell lines deficient in excision repair; 2) to continue studies to determine the nature of the damage signal transmitted to bystander cells including the expression of several connexins in the bystander response, and the extent to which the enhanced oxidative metabolism observed in bystander cells may relate to the nature of the transmitted bystander signal; 3) to utilize a genome-wide approach to examine the genetic basis for the hypersensitivity to ionization we have observed in unaffected parents of patients with hereditary retinoblastoma, as well as from a group of apparently normal individuals that show similar radiosensitivity; 4) to complete studies concerning the induction of high frequencies of cells with massive chromosome damage in clonal derivatives of p53 and p21 knockout mouse cell lines; in particular to examine the role of telomere changes in this phenomenon. Overall, the results of these studies should enhance our understanding of the risk of low-dose exposures to ionizing radiation, including human populations to residential radon as well as occupational exposures.

  18. Non-Ionizing Radiation Used in Microwave Ovens

    Science.gov (United States)

    ... Non-Ionizing Radiation Used in Microwave Ovens Non-Ionizing Radiation Used in Microwave Ovens Explore the interactive, virtual ... can do Where to learn more About Non-Ionizing Radiation Used in Microwave Ovens Microwave Oven. Microwave ovens ...

  19. Experimental comparison of models for ultrafast impact ionization is silicon

    DEFF Research Database (Denmark)

    Tarekegne, Abebe Tilahun; Iwaszczuk, Krzysztof; Jepsen, Peter Uhd

    2016-01-01

    We compare experimentally the exponential and quadratic (Keldysh formula) impact ionization models using THz induced impact ionization in silicon. We demonstrate that the exponential model offers the best description of impact ionization process for ultrashort electric filed pulses.......We compare experimentally the exponential and quadratic (Keldysh formula) impact ionization models using THz induced impact ionization in silicon. We demonstrate that the exponential model offers the best description of impact ionization process for ultrashort electric filed pulses....

  20. Ionization Cooling using Parametric Resonances

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland P.

    2008-06-07

    Ionization Cooling using Parametric Resonances was an SBIR project begun in July 2004 and ended in January 2008 with Muons, Inc., (Dr. Rolland Johnson, PI), and Thomas Jefferson National Accelerator Facility (JLab) (Dr. Yaroslav Derbenev, Subcontract PI). The project was to develop the theory and simulations of Parametric-resonance Ionization Cooling (PIC) so that it could be used to provide the extra transverse cooling needed for muon colliders in order to relax the requirements on the proton driver, reduce the site boundary radiation, and provide a better environment for experiments. During the course of the project, the theoretical understanding of PIC was developed and a final exposition is ready for publication. Workshops were sponsored by Muons, Inc. in May and September of 2007 that were devoted to the PIC technique. One outcome of the workshops was the interesting and somewhat unexpected realization that the beam emittances using the PIC technique can get small enough that space charge forces can be important. A parallel effort to develop our G4beamline simulation program to include space charge effects was initiated to address this problem. A method of compensating for chromatic aberrations by employing synchrotron motion was developed and simulated. A method of compensating for spherical aberrations using beamline symmetry was also developed and simulated. Different optics designs have been developed using the OptiM program in preparation for applying our G4beamline simulation program, which contains all the power of the Geant4 toolkit. However, no PIC channel design that has been developed has had the desired cooling performance when subjected to the complete G4beamline simulation program. This is believed to be the consequence of the difficulties of correcting the aberrations associated with the naturally large beam angles and beam sizes of the PIC method that are exacerbated by the fringe fields of the rather complicated channel designs that have been

  1. Ionization Cooling using Parametric Resonances

    International Nuclear Information System (INIS)

    Johnson, Rolland P.

    2008-01-01

    Ionization Cooling using Parametric Resonances was an SBIR project begun in July 2004 and ended in January 2008 with Muons, Inc., (Dr. Rolland Johnson, PI), and Thomas Jefferson National Accelerator Facility (JLab) (Dr. Yaroslav Derbenev, Subcontract PI). The project was to develop the theory and simulations of Parametric-resonance Ionization Cooling (PIC) so that it could be used to provide the extra transverse cooling needed for muon colliders in order to relax the requirements on the proton driver, reduce the site boundary radiation, and provide a better environment for experiments. During the course of the project, the theoretical understanding of PIC was developed and a final exposition is ready for publication. Workshops were sponsored by Muons, Inc. in May and September of 2007 that were devoted to the PIC technique. One outcome of the workshops was the interesting and somewhat unexpected realization that the beam emittances using the PIC technique can get small enough that space charge forces can be important. A parallel effort to develop our G4beamline simulation program to include space charge effects was initiated to address this problem. A method of compensating for chromatic aberrations by employing synchrotron motion was developed and simulated. A method of compensating for spherical aberrations using beamline symmetry was also developed and simulated. Different optics designs have been developed using the OptiM program in preparation for applying our G4beamline simulation program, which contains all the power of the Geant4 toolkit. However, no PIC channel design that has been developed has had the desired cooling performance when subjected to the complete G4beamline simulation program. This is believed to be the consequence of the difficulties of correcting the aberrations associated with the naturally large beam angles and beam sizes of the PIC method that are exacerbated by the fringe fields of the rather complicated channel designs that have been

  2. Laser-induced ionization of Na vapor

    International Nuclear Information System (INIS)

    Wu, R.C.Y.; Judge, D.L.; Roussel, F.; Carre, B.; Breger, P.; Spiess, G.

    1982-01-01

    The production of Na 2 + ions by off-resonant laser excitation in the 5800-6200A region mainly results from two-photon absorption by the Na 2 molecule to highly excited gerade states followed by (a) direct ionization by absorbing a third photon or (b) coupling to the molecular Na 2 D 1 PIμ Rydberg state which is subsequently ionized by absorbing a third photon. This mechanism, i.e., a two-photon resonance three photon ionization process, explains a recent experimental observation of Roussel et al. It is suggested that the very same mechanism is also responsible for a similar observation reported by Polak-Dingels et al in their work using two crossed Na beams. In the latter two studies the laser-induced associative ionization processes were reported to be responsible for producing the Na 2 + ion. From the ratio of molecular to atomic concentration in the crossed beam experiment of Polak-Dingels et al we estimate that the cross section for producing Na 2 + through laser-induced associative ionization is at least four orders of magnitude smaller than ionization through the two-photon resonance three photon ionization process in Na 2 molecules

  3. Neutron accelerator tube having improved ionization section

    International Nuclear Information System (INIS)

    Givens, W.W.

    1981-01-01

    A neutron accelerator tube having a target section, an ionization section, and a replenisher section for supplying accelerator gas to the ionization section. The ionization section is located between the target and the replenisher section and includes an ionization chamber adapted to receive accelerator gas from the replenisher section. The ionization section further includes spaced cathodes having opposed active surfaces exposed to the interior of the ionization chamber. An anode is located intermediate the cathodes whereby in response to an applied positive voltage, electrons created by field emmission are transmitted between the opposed active surfaces of the cathodes and produce the emission of secondary electrons. The active surface of at least one of the cathodes is formulated of a material having a secondary electron emission factor of at least 2. One cathode member located in the tube adjacent to the replenisher section may have a protuberant portion extending axially into the ioization chamber. The other cathode spaced from the first cathode member in the direction of the target has an aperture therein along the axis of the protuberant portion. An annular magnet extends around the exterior of the ionization chamber and envelops the anode member. Means are provided to establish a high permeability magnetic flux path extending outwardly from the opposed poles from the magnet to the active surfaces of the cathode members

  4. Regulation on protection against ionizing radiations

    International Nuclear Information System (INIS)

    1995-01-01

    This regulation has as the objective to establish the criteria tending toward protecting the health of the population of the radiologic risks that can be derive from the employment of the ionizing radiations and similar activities. It establishes the requirements to comply with the radiactive installations, equipment transmitters of ionizing radiations, personal that works in them, operate the equipment and carry out any another similar activity such as: production, importation, exportation, transportation, transference of radioactive material or equipment generators of radiations ionizing. (S. Grainger) [es

  5. Effects of ionizing radiation on life

    International Nuclear Information System (INIS)

    Rausch, L.

    1982-01-01

    Radiobiology in the last years was able to find detailed explanations for the effects of ionizing radiation on living organisms. But it is still impossible to make exact statements concerning the damages by radiation. Even now, science has to content itself with probability data. Moreover no typical damages of ionizing radiation can be identified. Therefore, the risks of ionizing radiation can only be determined by comparison with the spontaneous rate of cancerous or genetic defects. The article describes the interaction of high-energy radiation with the molecules of the organism and their consequences for radiation protection. (orig.)

  6. Ionization of atoms by bare ion projectiles

    International Nuclear Information System (INIS)

    Tribedi, L.C.

    1997-01-01

    The double differential cross sections (DDCS) for low energy electron emission can provide stringent tests to the theoretical models for ionization in ion-atom collision. The two-center effects and the post collision interactions play a major role in ionization by highly charged, high Z projectiles. We close-quote ll review the recent developments in this field and describe our efforts to study the energy and angular distributions of the low energy electrons emitted in ion-atom ionization. copyright 1997 American Institute of Physics

  7. Radionuclide measurements using resonantly enhanced collisional ionization

    International Nuclear Information System (INIS)

    Whitaker, T.J.; Bushaw, B.A.; Gerke, G.K.

    1987-01-01

    This report describes development of a laser-enhanced collisional ionization method for direct radionuclide measurements that are independent of radioactive decay. The technique uses two nitrogen-laser-pumped dye lasers to selectively excite the target isotope to an electronic state near the ionization threshold. The excited actinide atoms then undergo collisions with a buffer gas and are efficiently ionized. The resulting ions can be detected by conventional methods. The attributes of this approach include highly sensitive isotope analysis with relatively inexpensive lasers and a simple vacuum system. 9 refs., 3 figs

  8. Leukemia and ionizing radiation revisited

    Energy Technology Data Exchange (ETDEWEB)

    Cuttler, J.M. [Cuttler & Associates Inc., Vaughan, Ontario (Canada); Welsh, J.S. [Loyola University-Chicago, Dept. or Radiation Oncology, Stritch School of Medicine, Maywood, Illinois (United States)

    2016-03-15

    A world-wide radiation health scare was created in the late 19508 to stop the testing of atomic bombs and block the development of nuclear energy. In spite of the large amount of evidence that contradicts the cancer predictions, this fear continues. It impairs the use of low radiation doses in medical diagnostic imaging and radiation therapy. This brief article revisits the second of two key studies, which revolutionized radiation protection, and identifies a serious error that was missed. This error in analyzing the leukemia incidence among the 195,000 survivors, in the combined exposed populations of Hiroshima and Nagasaki, invalidates use of the LNT model for assessing the risk of cancer from ionizing radiation. The threshold acute dose for radiation-induced leukemia, based on about 96,800 humans, is identified to be about 50 rem, or 0.5 Sv. It is reasonable to expect that the thresholds for other cancer types are higher than this level. No predictions or hints of excess cancer risk (or any other health risk) should be made for an acute exposure below this value until there is scientific evidence to support the LNT hypothesis. (author)

  9. Exposure to non ionizing radiations

    International Nuclear Information System (INIS)

    Campanella, L.; Dragone, R.; Pastorelli, A.

    2001-01-01

    In the last years the exposure levels to electric, magnetic and electromagnetic fields of workers and citizens have dramatically increased due to the technological development as in the exemplar case of cellular phones. The object of this research concerns the biological evaluation of the risk from exposure to non ionizing radiations (NIR) by an opportunely designed biosensor based on immobilized Saccharomyces cerevisiae cells and by an amperometric transducer (Clark oxygen electrode). The results have been obtained by comparing the respiratory activities of exposed and not exposed yeast cells to NIR (at 900 MHz, frequency of the first generation cellular phones). The measurements have been performed by irradiation of the cells in a G-TEM chamber. The obtained results clearly show a decrease of the respiration activity of the irradiation cells in comparison with blank. This variation results to be proportional to the exposure time. Concerning reversibility of the damage it seems that the recovery of the initial conditions begins after 4 hours since the end of exposition and is complete within the following 48 hrs [it

  10. Neutron-sensitive ionization chamber

    International Nuclear Information System (INIS)

    Mayer, W.

    1978-01-01

    The neutron-sensitive ionization chamber which is to be applied for BWRs consists of a cylindrical outer electrode, closed at the ends, and a concentrically arranged inner electrode. It is designed as a hollow tube and coated with uranium on the outside. The reaction space lies between the two electrodes. The electrical connection is obtained through a coaxial cable whose nickel helix is properly intorduced into the inner electrode made of titanium or nickel. The sheathing respectively external conductor of the cable has got the same diameter as the outer electrode and is butt-welded to it. Between the cable helix and the sheathing there is filled Al 2 O 3 powder. The reaction space is sealed against the cable by means of a little tube pushed over the internal conductor resp. the helix. It consists of Ni resp. Al 2 O 3 which is coated on the outside at first by a layer of Al 2 O 3 and a layer of Ni resp. by a metal layer on the inside and on the outside. (DG) [de

  11. Ionizing radiation and thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hall, P. (Karolinska Inst., Stockholm (Sweden). Inst. of Environmental Medicine); Holm, L.E. (Swedish Radiation Protection Inst., Stockholm (Sweden))

    1994-01-01

    Epidemiological studies provide the primary data source on cancer risk in man after exposure to ionizing radiation. The present paper discusses methodological difficulties in epidemiological studies and reviews current epidemiological knowledge on radiation-induced thyroid cancer. Most studies of radiation-induced cancer are of a ''historical observational'' type and are also non-experimental in design. Seldom is there an opportunity to consider other factors playing on cancer risk. Since many of the study subjects were exposed a long time ago there could also be difficulties in calculating the radiation doses, and to identify and follow the exposed subjects. Short exposure to low doses of gamma radiation can induce thyroid cancer in children, whereas a relationship between protracted low-dose exposure and thyroid cancer has not been established so far. The most important future issues concerning radiation-induced thyroid cancer are the risks following low radiation doses and/or protracted radiation exposure and cancer risks after [sup 131]I exposure in childhood. (authors). 35 refs., 3 tabs.

  12. Biological Effects of Ionizing Radiation

    International Nuclear Information System (INIS)

    Durand, J.L.

    2000-01-01

    The aim of this work is to verify the existence of the adaptive response phenomenon induced by low doses of ionizing radiation in living cells.A wild-type yeast Saccharomyces cerevisiae (Baker's yeast) was chosen as the biological target.As a parameter to quantify the sensibility of the target to radiation, the Lethal Dose 50 (LD50 ) was observed. In our experimental condition a value of (60 ± 1) Gy was measured for LD50 with Dose Rate of (0.44 ± 0.03) Gy/min. The method employed to show up the adaptive response phenomenon consisted in exposing the sample to low ''conditioning'' doses, which would initiate these mechanisms. Later the samples with and without conditioning were exposed to higher ''challenging'' doses (such as LD50), and the surviving fractions were compared. In order to maximize the differences, the doses and the time between irradiations were varied. The best results were obtained with both a conditioning dose of (0.44 ± 0.03) Gy and a waiting time of 2 hs until the application of the challenging dose. Following this procedures the 80% of the conditioned samples has survived, after receiving the application of the LD50. The adaptive response phenomenon was also verified for a wide range of challenging doses

  13. Sterilizing insects with ionizing radiation

    International Nuclear Information System (INIS)

    Bakri, A.; Mehta, K.; Lance, D.R.

    2005-01-01

    Exposure to ionizing radiation is currently the method of choice for rendering insects reproductively sterile for area-wide integrated pest management (AW-IPM) programmes that integrate the sterile insect technique (SIT). Gamma radiation from isotopic sources (cobalt-60 or caesium-137) is most often used, but high-energy electrons and X-rays are other practical options. Insect irradiation is safe and reliable when established safety and quality-assurance guidelines are followed. The key processing parameter is absorbed dose, which must be tightly controlled to ensure that treated insects are sufficiently sterile in their reproductive cells and yet able to compete for mates with wild insects. To that end, accurate dosimetry (measurement of absorbed dose) is critical. Irradiation data generated since the 1950s, covering over 300 arthropod species, indicate that the dose needed for sterilization of arthropods varies from less than 5 Gy for blaberid cockroaches to 300 Gy or more for some arctiid and pyralid moths. Factors such as oxygen level, and insect age and stage during irradiation, and many others, influence both the absorbed dose required for sterilization and the viability of irradiated insects. Consideration of these factors in the design of irradiation protocols can help to find a balance between the sterility and competitiveness of insects produced for programmes that release sterile insects. Many programmes apply 'precautionary' radiation doses to increase the security margin of sterilization, but this overdosing often lowers competitiveness to the point where the overall induced sterility in the wild population is reduced significantly. (author)

  14. RILIS-ionized mercury and tellurium beams at ISOLDE CERN

    Energy Technology Data Exchange (ETDEWEB)

    Day Goodacre, T., E-mail: thomas.day.goodacre@cern.ch [CERN (Switzerland); Billowes, J. [The University of Manchester, School of Physics and Astronomy (United Kingdom); Chrysalidis, K. [CERN (Switzerland); Fedorov, D. V. [Petersburg Nuclear Physics Institute (Russian Federation); Fedosseev, V. N.; Marsh, B. A. [CERN (Switzerland); Molkanov, P. L. [Petersburg Nuclear Physics Institute (Russian Federation); Rossel, R. E.; Rothe, S.; Seiffert, C. [CERN (Switzerland); Wendt, K. D. A. [Johannes Gutenberg Universität, Institut für Physik (Germany)

    2017-11-15

    This paper presents the results of ionization scheme development for application at the ISOLDE Resonance Ionization Laser Ion Source (RILIS). Two new ionization schemes for mercury are presented: a three-step three-resonance ionization scheme, ionizing via an excitation to a Rydberg level and a three-step two-resonance ionization scheme, with a non-resonant final step to the ionization continuum that corresponded to a factor of four higher ionization efficiency. The efficiency of the optimal mercury ionization scheme was measured, together with the efficiency of a new three-step three resonance ionization scheme for tellurium. The efficiencies of the mercury and tellurium ionization schemes were determined to be 6 % and >18 % respectively.

  15. Surface-ionization field mass-spectrometry studies of nonequilibrium surface ionization

    International Nuclear Information System (INIS)

    Blashenkov, Nikolai M; Lavrent'ev, Gennadii Ya

    2007-01-01

    The ionization of polyatomic molecules on tungsten and tungsten oxide surfaces is considered for quasiequilibrium or essentially nonequilibrium conditions (in the latter case, the term nonequilibrium surface ionization is used for adsorbate ionization). Heterogeneous reactions are supposed to proceed through monomolecular decay of polyatomic molecules or fragments of multimolecular complexes. The nonequilibrium nature of these reactions is established. The dependences of the current density of disordered ions on the surface temperature, electric field strength, and ionized particle energy distribution are obtained in analytical form. Heterogeneous dissociation energies, the ionization potentials of radicals, and the magnitude of reaction departure from equilibrium are determined from experimental data, as are energy exchange times between reaction products and surfaces, the number of molecules in molecular complexes, and the number of effective degrees of freedom in molecules and complexes. In collecting the data a new technique relying on surface-ionization field mass-spectrometry was applied. (instruments and methods of investigation)

  16. Multiple ionization of atoms by ion impact

    International Nuclear Information System (INIS)

    DuBois, R.D.

    1988-01-01

    In order to model the energy deposition of fast ions as they slow down in gaseous media, information about the ionization occurring in collisions between ions and target atoms/molecules is required. Our measurements of doubly differential electron emission cross sections provide detailed information about the ionization process but do not provide any information about the final states of the target. They also do not distinguish between the emission of one or more target electrons in a single collision. It is important to know the relative importance of multiple-, with respect to single-, target ionization in order to accurately model the energy deposition. To date, multiple ionization of He, Ne, Ar, Kr, and Xe targets has been studied. Primarily, H and He ions were used, although some data for heavier ions (C,N and O) have also been obtained

  17. Propagation of ionizing waves in glow discharge

    International Nuclear Information System (INIS)

    Suzuki, T.

    1977-01-01

    Ionizing waves were produced along the positive column of a glow discharge in air by applying an impulse voltage to an electrode at one end of the column. Five photomultipliers and three current-sensing coils were used to observe how the waves were affected by the rise time and the magnitude of the applied impulses and by the electron density in the positive column of the glow discharge. It is shown that the speed of the ionizing waves increases with the slope of the applied impulses and with the preexisting electron density. The electron density is augmented about 100--200 times due to the buildup of ionization at the front of the waves. The theory was developed to explain the property of ionizing waves

  18. Experiments on Coulomb ionization by charged particles

    International Nuclear Information System (INIS)

    Andersen, J.U.; Laegsgaard, E.; Lund, M.

    1978-01-01

    Inner-shell ionization by light projectiles, i.e., in very asymmetric collisions, is often denoted 'Coulomb ionization' because it is caused by the Coulomb interaction between the electron and the projectile. Although with little justification, the term is also used to distinquish such processes, in which the projectile Coulomb field is a small perturbation, from ionization in more violent, nearly symmetric ion-atom collisions. A discussion of Coulomb ionization of atomic K shells is given, with emphasis on experimental methods and results. The discussion is not intended as a review of the field but rather as a progress report on the anthor's work on the subject. A more detailed account was recently presented at the ICPEAC meeting in Paris. (Auth.)

  19. New Croatian Act on Ionizing Radiation Protection

    International Nuclear Information System (INIS)

    Grgic, S.

    1998-01-01

    According to the new Croatian Act on ionizing radiation protection which is in a final stage of genesis, Ministry of Health of the Republic of Croatia is the governmental body responsible for all aspects relating sources of ionizing radiation in Croatia: practices, licenses, users, transport, in medicine and industry as well, workers with sources of ionizing radiation, emergency preparedness in radiological accidents, storage of radioactive wastes, x-ray machines and other machines producing ionizing radiation and radioactive materials in the environment. Ministry of Health is responsible to the Government of the Republic of Croatia, closely collaborating with the Croatian Radiation Protection Institute, health institution for the performance of scientific and investigation activities in the field of radiation protection. Ministry of Health is also working together with the Croatian Institute for the Occupational Health. More emphasis has been laid on recent discussion among the world leading radiation protection experts on justification of the last recommendations of the ICRP 60 publication. (author)

  20. Specification for symbol for ionizing radiation

    International Nuclear Information System (INIS)

    1974-01-01

    This Malaysia Standard specification specifies a symbol recommended for use only to signify the actual or potential presence of ionizing radiation (#betta#, α, #betta# only) and to identify objects, devices, materials or combinations of materials which emit such radiation. (author)

  1. Electron impact ionization of large krypton clusters

    Institute of Scientific and Technical Information of China (English)

    Li Shao-Hui; Li Ru-Xin; Ni Guo-Quan; Xu Zhi-Zhan

    2004-01-01

    We show that the detection of ionization of very large van der Waals clusters in a pulsed jet or a beam can be realized by using a fast ion gauge. Rapid positive feedback electron impact ionization and fragmentation processes,which are initially ignited by electron impact ionization of the krypton clusters with the electron current of the ion gauge, result in the appearance of a progressional oscillation-like ion spectrum, or just of a single fast event under critical conditions. Each line in the spectrum represents a correlated explosion or avalanche ionization of the clusters.The phenomena have been analysed qualitatively along with a Rayleigh scattering experiment of the corresponding cluster jet.

  2. Tachyonic ionization cross sections of hydrogenic systems

    Energy Technology Data Exchange (ETDEWEB)

    Tomaschitz, Roman [Department of Physics, Hiroshima University, 1-3-1 Kagami-yama, Higashi-Hiroshima 739-8526 (Japan)

    2005-03-11

    Transition rates for induced and spontaneous tachyon radiation in hydrogenic systems as well as the transversal and longitudinal ionization cross sections are derived. We investigate the interaction of the superluminal radiation field with matter in atomic bound-bound and bound-free transitions. Estimates are given for Ly-{alpha} transitions effected by superluminal quanta in hydrogen-like ions. The tachyonic photoelectric effect is scrutinized, in the Born approximation and at the ionization threshold. The angular maxima occur at different scattering angles in the transversal and longitudinal cross sections, which can be used to sift out longitudinal tachyonic quanta in a photon flux. We calculate the tachyonic ionization and recombination cross sections for Rydberg states and study their asymptotic scaling with respect to the principal quantum number. At the ionization threshold of highly excited states of order n {approx} 10{sup 4}, the longitudinal cross section starts to compete with photoionization, in recombination even at lower levels.

  3. Genetic effects of ionizing radiations in Eucaryocytes

    International Nuclear Information System (INIS)

    Jullien, Pierre

    1976-01-01

    The litterature on the genetic effects of ionizing radiations is reviewed, especially as concerns specific loci or chromosome mutations. Extrapolation from one species to another is considered as well as extra-nuclear mutations [fr

  4. Liquid ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki

    Liquid ionization chambers [1] (LICs) have have been used in the last decades as background dosemeters. Since a few years LICs are also commercially available for dosimetry and are used for measurements of dose distributions where a high spatial distribution is necessary. Also in the last decades...... a differential equation applying several simplifications and approximations leading to discrepancies between theory and experiments [3]. The theory predicts the collection efficiency as a function of the electrical field and was applied for both air filled ionization chambers and liquid filled ionization...... chambers. For liquids the LET can be roughly deduced from the collection efficiency dependency on the electrical field inside a liquid ionization chambers [4] using an extrapolation method. We solved the fundamental differential equation again presented by Jaffe numerically, but now taking into account...

  5. The critical ionization velocity - a bibliography

    International Nuclear Information System (INIS)

    Axnaes, I.; Brenning, N.; Raadu, M.A.

    1982-12-01

    A list of all relevant contributions, known to the authors, concerning the critical ionization velocity phenomena is presented. The contributions are classified and described in a few sentences. (Authors)

  6. The effect of ionizing radiation on cyanophyta

    International Nuclear Information System (INIS)

    Kondrat'eva, N.V.; Shevchenko, T.F.; Golubkova, M.G.

    1989-01-01

    Publication data on the effect of ionizing radiation on cyanophyta are generalized. The conclusion about the presence of premises for forming cyanophyta radiobiology as special direction of procaryotic algae investigation is made

  7. Penning ionization processes studied by electron spectroscopy

    International Nuclear Information System (INIS)

    Yencha, A.J.

    1978-01-01

    The technique of measuring the kinetic energy of electrons ejected from atomic or molecular species as a result of collisional energy transfer between a metastable excited rare gas atom and an atom or molecule is known as Penning ionization spectroscopy. Like the analogous photoionization process of photoelectron spectroscopy, a considerable amount of information has been gained about the ionization potentials of numerous molecular systems. It is, in fact, through the combined analyses of photoelectron and Penning electron spectra that affords a probe of the particle-particle interactions that occur in the Penning process. In this paper a short survey of the phenomenon of Penning ionization, as studied by electron spectroscopy, will be presented as it pertains to the ionization processes of simple molecules by metastable excited atoms. (author)

  8. Modeling of Plutonium Ionization Probabilities for Use in Nuclear Forensic Analysis by Resonance Ionization Mass Spectrometry

    Science.gov (United States)

    2016-12-01

    masses collide, they form a supercritical mass . Criticality refers to the neutron population within the system. A critical system is one that can...Spectrometry, no. 242, pp. 161–168, 2005. [9] S. Raeder, “Trace analysis of actinides in the environment by means of resonance ionization mass ...first ionization potential of actinide elements by resonance ionization mass spectrometry.” Spectrochimica Acta part B: Atomic Spectroscopy. vol. 52

  9. Quantification of the Triazole Antifungal Compounds Voriconazole and Posaconazole in Human Serum or Plasma Using Liquid Chromatography Electrospray Tandem Mass Spectrometry (HPLC-ESI-MS/MS).

    Science.gov (United States)

    Molinelli, Alejandro R; Rose, Charles H

    2016-01-01

    Voriconazole and posaconazole are triazole antifungal compounds used in the treatment of fungal infections. Therapeutic drug monitoring of both compounds is recommended in order to guide drug dosing to achieve optimal blood concentrations. In this chapter we describe an HPLC-ESI-MS/MS method for the quantification of both compounds in human plasma or serum following a simple specimen preparation procedure. Specimen preparation consists of protein precipitation using methanol and acetonitrile followed by a cleanup step that involves filtration through a cellulose acetate membrane. The specimen is then injected into an HPLC-ESI-MS/MS equipped with a C18 column and separated over an acetonitrile gradient. Quantification of the drugs in the specimen is achieved by comparing the response of the unknown specimen to that of the calibrators in the standard curve using multiple reaction monitoring.

  10. Efficient mining of myxobacterial metabolite profiles enabled by liquid chromatography-electrospray ionisation-time-of-flight mass spectrometry and compound-based principal component analysis

    International Nuclear Information System (INIS)

    Krug, Daniel; Zurek, Gabriela; Schneider, Birgit; Garcia, Ronald; Mueller, Rolf

    2008-01-01

    Bacteria producing secondary metabolites are an important source of natural products with highly diverse structures and biological activities. Developing methods to efficiently mine procaryotic secondary metabolomes for the presence of potentially novel natural products is therefore of considerable interest. Modern mass spectrometry-coupled liquid chromatography can effectively capture microbial metabolic diversity with ever improving sensitivity and accuracy. In addition, computational and statistical tools increasingly enable the targeted analysis and exploration of information-rich LC-MS datasets. In this article, we describe the use of such techniques for the characterization of myxobacterial secondary metabolomes. Using accurate mass data from high-resolution ESI-TOF measurements, target screening has facilitated the rapid identification of known myxobacterial metabolites in extracts from nine Myxococcus species. Furthermore, principal component analysis (PCA), implementing an advanced compound-based bucketing approach, readily revealed the presence of further compounds which contribute to variation among the metabolite profiles under investigation. The generation of molecular formulae for putative novel compounds with high confidence due to evaluation of both exact mass position and isotopic pattern, is exemplified as an important key for de-replication and prioritization of candidates for further characterization

  11. Identification of Sarin and Related Compounds in Snow by Packed Capillary Liquid Chromatography-Electrospray Mass Spectrometry (LC-ESI-MS)

    National Research Council Canada - National Science Library

    D'Agostino, Paul

    2001-01-01

    Packed capillary LC-ESl-MS was used for the analysis of a snow sample that was accidentally contaminated with an organophosphorus chemical warfare agent during the destruction of a chemical munition...

  12. Ultra-trace-level determination of polar pesticides and their transformation products in surface and estuarine water samples using column liquid chromatography electrospray-tandem mass spectrometry

    NARCIS (Netherlands)

    Steen, R.J.C.A.; Hogenboom, A.C.; Leonards, P.E.G.; Peerboom, R.A.L.; Cofino, W.P.; Brinkman, U.A.T.

    1999-01-01

    A method is developed for the determination of polar pesticides and their transformation products [atrazine, deethylatrazine, deisopropylatrazine, hydroxyatrazine, diuron, 3,4-dichlorophenylmethylurea, 3,4-dichlorophenylurea (DPU), monuron, bentazone, anthranil-isopropylamide, chloridazon,

  13. Quantification of sulfatides in dried blood and urine spots from metachromatic leukodystrophy patients by liquid chromatography/electrospray tandem mass spectrometry.

    Science.gov (United States)

    Barcenas, Mariana; Suhr, Teryn R; Scott, C Ronald; Turecek, Frantisek; Gelb, Michael H

    2014-06-10

    Treatments are being developed for metachromatic leukodystrophy (MLD), suggesting the need for eventual newborn screening. Previous studies have shown that sulfatide molecular species are increased in the urine of MLD patients compared to samples from non-MLD individuals, but there is no data using dried blood spots (DBS), the most common sample available for newborn screening laboratories. We used ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) to quantify sulfatides in DBS and dried urine spots from 14 MLD patients and 50 non-MLD individuals. Several sulfatide molecular species were increased in dried urine samples from all MLD samples compared to non-MLD samples. Sulfatides, especially low molecular species, were increased in DBS from MLD patients, but the sulfatide levels were relatively low. There was good separation in sulfatide levels between MLD and non-MLD samples when dried urine spots were used, but not with DBS, because DBS from non-MLD individuals have measurable levels of sulfatides. Sulfatide accumulation studies in urine, but not in DBS, emerges as the method of choice if newborn screening is to be proposed for MLD. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Determination of 5-hydroxy-N-methyl-2-pyrrolidone and 2-hydroxy-N-methylsuccinimide in human plasma and urine using liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Carnerup, M A; Akesson, B; Jönsson, B A

    2001-09-15

    A method for simultaneous determination of 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methylsuccinimide (2-HMSI) was developed. These compounds are metabolites from N-methyl-2-pyrrolidone (NMP), a powerful and widely used organic solvent. 5-HNMP and 2-HMSI were purified from plasma and urine by solid-phase extraction using Isolute ENV+ columns, and analysed by liquid chromatography coupled to a mass spectrometer fitted with an atmospheric pressure turbo ion spray ionisation interface in the positive ion mode. The method was validated for plasma and urine concentrations from 0.12 to 25 microg/ml. The recoveries for 5-HNMP and 2-HMSI in plasma were 99 and 98%, respectively, and in urine 111 and 106%, respectively. For 5-HNMP and 2-HMSI, the within-day precision in plasma was 1-4 and 3-6%, respectively, and in urine 2-12 and 3-10%, respectively. The corresponding data for the between-day precision was 5 and 3-6%, respectively, and 4-6 and 7-8%, respectively. The detection limit for 5-HNMP was 4 ng/ml in plasma and 120 ng/ml in urine. For 2-HMSI, it was 5 ng/ml in plasma and 85 ng/ml in urine. The method is applicable for analysis of plasma and urine samples from workers exposed to NMP.

  15. Determination of denaturated proteins and biotoxins by on-line size-exclusion chromatography-digestion-liquid chromatography-electrospray mass spectrometry

    NARCIS (Netherlands)

    Carol, J.; Gorseling, M.C.J.K.; Jong, C.F. de; Lingeman, H.; Kientz, C.E.; Baar, B.L.M. van; Irth, H.

    2005-01-01

    A multidimensional analytical method for the rapid determination and identification of proteins has been developed. The method is based on the size-exclusion fractionation of protein-containing samples, subsequent on-line trypsin digestion and desalination, and reversed-phase high-performance liquid

  16. Analysis of the monosaccharide composition of water-soluble polysaccharides from Sargassum fusiforme by high performance liquid chromatography/electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Wu, Xiaodan; Jiang, Wei; Lu, Jiajia; Yu, Ying; Wu, Bin

    2014-02-15

    Sargassum fusiforme (hijiki) is the well-known edible algae, whose polysaccharides have been proved to possess interesting bioactivities like antitumor, antioxidant, antimicrobial and immunomodulatory activities. A facile and sensitive method based on high-performance liquid chromatography method of pre-column derivatization with 1-phenyl-3-methyl-5-pyrazolone (PMP) coupled with electrospray ionisation mass spectrometry (HPLC/ESI-MS) has been established for the analysis of the monosaccharide composition of polysaccharides in S. fusiforme. Monosaccharides have been converted into PMP-labelled derivatives with aqueous ammonia as a catalyst at 70 °C for 30 min. The optimisation of the pre-column derivatization process was studied. The LODs of the monosaccharides were in the range from 0.01 to 0.02 nmol. PMP-labelled mixture of monosaccharides has been well separated by a reverse-phase HPLC and detected by on-line ESI-MS method under optimised conditions. The mobile phase of elution system was chosen as acetonitrile (solvent A) and 20mM aqueous ammonium acetate (solvent B) (pH 3.0) with Zorbax XDB-C18 column at 30 °C for the separation of the monosaccharide derivatives. Identification of the monosaccharides composition was carried out by analysis with mass spectral behaviour and chromatography characteristics of 1-phenyl-3-methyl-5-pyrazolone (PMP) labelled monosaccharides. All PMP-labelled derivatives display high chemical stabilities, whose regular MS fragmentation is specific for reducing labelled sugars. The result showed that the S. fusiforme polysaccharide consisted of mannose, glucose, galactose, xylose, fucose and glucuronic acid or galacturonic acid, or both uronic acids. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Analytical study of azadirachtin and 3-tigloylazadirachtol residues in foliage and phloem of hardwood tree species by liquid chromatography-electrospray mass spectrometry.

    Science.gov (United States)

    Grimalt, Susana; Thompson, Dean G; Coppens, Melanie; Chartrand, Derek T; Shorney, Thomas; Meating, Joe; Scarr, Taylor

    2011-08-10

    A rapid and sensitive LC-ESI-MS method has been developed and validated for the quantitation of azadirachtin and 3-tigloylazadirachtol in deciduous tree matrices. The method involves automated extraction and simultaneous cleanup using an accelerated solvent technique with the matrix dispersed in solid phase over a layer of primary-secondary amine silica. The limits of quantification were 0.02 mg/kg for all matrices with the exception of Norway maple foliage (0.05 mg/kg). Validation at three levels (0.02, 0.1, and 1 mg/kg), demonstrated satisfactory recoveries (71-103%) with relative standard deviation <20%. Two in-source fragment ions were used for confirmation at levels above 0.1 mg/kg. Over a period of several months, quality control analyses showed the technique to be robust and effective in tracking the fate of these natural botanical insecticides following systemic injection into various tree species for control of invasive insect pest species such as the emerald ash borer and Asian longhorned beetle.

  18. Simultaneous determination of phenolic compounds in Cynthiana grape (Vitis aestivalis) by high performance liquid chromatography-electrospray ionisation-mass spectrometry.

    Science.gov (United States)

    Ramirez-Lopez, L M; McGlynn, W; Goad, C L; Mireles Dewitt, C A

    2014-04-15

    Phenolic acids, flavanols, flavonols and stilbenes (PAFFS) were isolated from whole grapes, juice, or pomace and purified using enzymatic hydrolysis. Only anthocyanin mono-glucosides and a few of the oligomers from Cynthiana grape (Vitis aestivalis) were analysed. Flavonoid-anthocyanin mono-glucosides (FA) were isolated using methanol/0.1% hydrochloric acid extraction. In addition, crude extractions of phenolic compounds from Cynthiana grape using 50% methanol, 70% methanol, 50% acetone, 0.01% pectinase, or petroleum ether were also evaluated. Reverse phase high performance liquid chromatography (RP-HPLC) with photodiode array (PDA) detector was used to identify phenolic compounds. A method was developed for simultaneous separation, identification and quantification of both PAFFS and FA. Quantification was performed by the internal standard method using a five points regression graph of the UV-visible absorption data collected at the wavelength of maximum absorbance for each analyte. From whole grape samples nine phenolic compounds were tentatively identified and quantified. The individual phenolic compounds content varied from 3 to 875 mg kg⁻¹ dry weight. For juice, twelve phenolic compounds were identified and quantified. The content varied from 0.07 to 910 mg kg⁻¹ dry weight. For pomace, a total of fifteen phenolic compounds were tentatively identified and quantified. The content varied from 2 mg kg⁻¹ to 198 mg kg⁻¹ dry matter. Results from HPLC analysis of the samples showed that gallic acid and (+)-catechin hydrate were the major phenolic compounds in both whole grapes and pomace. Cyanidin and petunidin 3-O-glucoside were the major anthocyanin glucosides in the juice. Published by Elsevier Ltd.

  19. Ethyl glucuronide in vitreous humor and blood postmortem specimens: analysis by liquid chromatography-electrospray tandem mass spectrometry and interpreting results of neo-formation of ethanol

    Directory of Open Access Journals (Sweden)

    Sara Vezzoli

    2015-03-01

    Full Text Available Introduction. The determination of ethyl glucuronide (EtG, a stable and sensitive marker that is specific to alcohol intake, finds many applications both in the forensic toxicology and clinical fields. Aim. The aim of the study is to examine the possibility of using a cadaveric biological matrix, vitreous humor (VH, to determine EtG as a marker of recent ethanol use. Methods. The blood, taken from the femoral vein, and the VH were obtained from 63 autopsy cases. Analysis of the EtG was performed using an LC/MS/MS system. Analyses of the ethanol and putrefaction biomarkers, such as acetaldehyde and n-propanol, were performed using the HS-GC/FID technique in both the matrices. Results. In 17 cases, both ethanol and EtG were absent in both matrices.Nineteen cases presented ethanol in blood from 0.05 to 0.30 g/L, EtG-Blood concentration from 0.02 to 3.27 mg/L, and EtG-VH concentration from 0.01 mg/L to 2.88 mg/L. Thirteen cases presented ethanol in blood > 0.05 g/L but EtG concentration in blood and VH lower than 0.01 mg/L, are part of these 8 samples presented acetic aldehyde and n- propanol in blood or VH, means identification of putrefaction indicators. Fourteen cases presented ethanol in blood > 0.46 and EtG concentration in blood and VH higher than 0.01 mg/L. Conclusions. The determination of EtG in biological material is important in those cases where the intake of ethanol appears doubtful, as it allows us to exclude the possibility of any post-mortem formation of ethanol.

  20. Identification and quantification of five macrolide antibiotics in several tissues, eggs and milk by liquid chromatography-electrospray tandem mass spectrometry.

    Science.gov (United States)

    Dubois, M; Fluchard, D; Sior, E; Delahaut, P

    2001-04-05

    We present an electrospray high-performance liquid chromatographic tandem mass spectrometric (HPLC-MS-MS) method capable of determining in several tissues (muscle, kidney, liver), eggs and milk the following five macrolides: tylosin, tilmicosin, spiramycin, josamycin, erythromycin. Roxithromycin was used as an internal standard. The method uses extraction in a Tris buffer at pH 10.5, followed by protein precipitation with sodium tungstate and clean-up on an Oasis solid-phase extraction column. The HPLC separation was performed on a Purospher C18 column (125 x 3 mm I.D.) protected by a guard column, with a gradient of aqueous 0.1 M ammonium acetate-acetonitrile as the mobile phase at a flow-rate of 0.7 ml min(-1). Protonated molecules served as precursor ions for electrospray ionisation in the positive ion mode and four product ions were chosen for each analyte for multiple reaction monitoring (MRM). A validation study was conducted to confirm the five macrolides by MRM HPLC-MS-MS analysis of a negative control and fortified samples. All of the samples analysed were confirmed with four ions. The ion ratio reproducibility limit ranged from 2.4 to 15%. All compounds could be detected and quantified at half-maximum residue limits (MRLs). The method is specific, quantitative and reproducible enough to conform to European Union recommendations within the concentration range 0.5 MRL-2 MRL (accuracy: 80 to 110%, relative standard deviation: 2 to 13%). This whole method allows extraction and analysis of up to 50 samples per day.

  1. Effect of the mobile phase composition on the separation and detection of intact proteins by reversed-phase liquid chromatography-electrospray mass spectrometry

    NARCIS (Netherlands)

    Garcia, M.O.; Hogenboom, A.C.; Zappey, H.; Irth, H.

    2002-01-01

    Various buffers (ammonium acetate, ammonium formate, and ammonium hydrogencarbonate), acids (formic acid, acetic acid, heptafluorobutyric acid, and trifluoroacetic acid), and bases (ammonium hydroxide and morpholine) covering the range from 2 to 11.5 have been investigated for their performance in

  2. C18-coated stir bar sorptive extraction combined with high performance liquid chromatography-electrospray tandem mass spectrometry for the analysis of sulfonamides in milk and milk powder.

    Science.gov (United States)

    Yu, Chunhe; Hu, Bin

    2012-02-15

    A simple, rapid, sensitive, inexpensive and less sample consuming method of C(18)-stir bar sorptive extraction (SBSE)-high performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) was proposed for the determination of six sulfonamides in milk and milk powder samples. C(18) silica particles coated stir bar was prepared by adhesion method, and two kinds of adhesive glue, polydimethylsiloxane (PDMS) sol and epoxy glue were tried. It was found that the C(18)-coated stir bar prepared by PDMS sol as adhesive glue is more robust than that prepared by epoxy glue when liquid desorption was employed, in terms of both lifetime and organic solvent tolerance. The preparation of C(18) stir bar was simple with good mechanic strength and the stir bar could be reused for more than 20 times. Granular coating has relatively high specific surface area and is propitious to sorptive extraction based process. Compared to conventional PDMS SBSE coating, C(18) coating shows good affinity to the target polar/weak polar sulfonamides. To achieve optimum SBSE extraction performance, several parameters including extraction and desorption time, ionic strength, sample pH and stirring speed were investigated. The detection limits of the proposed method for six sulfonamides were in the range of 0.9-10.5 μg/L for milk and 2.7-31.5 μg/kg for milk powder. Good linearities were obtained for sulfonamides with the correlation coefficients (R) above 0.9922. Finally, the proposed method was successfully applied to the determination of sulfonamides in milk and milk powder samples and satisfied recoveries of spiked target compounds in real samples were obtained. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Conception of CTMSP ionizing radiation calibration laboratory

    International Nuclear Information System (INIS)

    Silva, Raimundo Dias da; Kibrit, Eduardo

    2009-01-01

    The present paper describes the implantation process of an ionizing radiation calibration laboratory in a preexistent installation in CTMSP (bunker) approved by CNEN to operate with gamma-ray for non destructive testing. This laboratory will extend and improve the current metrological capacity for the attendance to the increasing demand for services of calibration of ionizing radiation measuring instruments. Statutory and regulatory requirements for the licensing of the installation are presented and deeply reviewed. (author)

  4. Fundamental studies of molecular multiphoton ionization

    International Nuclear Information System (INIS)

    Miller, J.C.; Compton, R.N.

    1984-04-01

    For several years the authors have performed fundamental studies of molecular multiphoton ionization (MPI). We will present a potpourri of techniques and results chosen to illustrate the interesting complexities of molecular MPI. Techniques used include time-of-flight mass spectroscopy, photoelectron spectroscopy, supersonic expansion cooling of molecular beams, harmonic generation, two-color laser MPI, and polarization spectroscopy. Whenever possible the relevance of these results to resonance ionization spectroscopy schemes will be delineated. 23 references, 10 figures

  5. Bound electron nonlinearity beyond the ionization threshold

    OpenAIRE

    Wahlstrand, J. K.; Zahedpour, S.; Bahl, A.; Kolesik, M.; Milchberg, H. M.

    2018-01-01

    Although high field laser-induced ionization is a fundamental process underlying many applications, there have been no absolute measurements of the nonlinear polarizability of atoms and molecules in the presence of ionization. Such information is crucial, for example, for understanding the propagation of high intensity ultrashort pulses in matter. Here, we present absolute space- and time-resolved measurements of the ultrafast laser-driven nonlinear polarizability in argon, krypton, xenon, ni...

  6. Tomographic scanning apparatus with ionization detector means

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus using a fan beam and digital output signal. Particular reference is made to the gas-pressurized ionization detector chamber, consisting of an array of side-by-side elongate ionization detection cells, the principal axis of each of the said cells being oriented along a radius extending towards the radiation source, and connection means for applying potentials across the cells for taking their output signals. (U.K.)

  7. 100 years of ionizing radiation protection

    International Nuclear Information System (INIS)

    Baltrukiewicz, Z.; Musialowicz, T.

    1999-01-01

    The development of radiation protection from the end of 19. century and evolution of opinion about injurious effect of ionizing radiation were presented. Observations of undesirable effects of ionizing radiation exposition, progress of radiobiology and dosimetry directed efforts toward radiation protection. These activities covered, at the beginning, limited number of persons and were subsequently extended to whole population. The current means, goals and regulations of radiological control have been discussed

  8. Drift waves in a weakly ionized plasma

    DEFF Research Database (Denmark)

    Popovic, M.; Melchior, H.

    1968-01-01

    A dispersion relation for low frequency drift waves in a weakly ionized plasma has been derived, and through numerical calculations the effect of collisions between the charged and the neutral particles is estimated.......A dispersion relation for low frequency drift waves in a weakly ionized plasma has been derived, and through numerical calculations the effect of collisions between the charged and the neutral particles is estimated....

  9. Commercial applications of food ionization in France

    International Nuclear Information System (INIS)

    Santos, Pierre-Louis

    1994-01-01

    Due to the long history of nuclear energy in France, French public is not frightened by nuclear applications in its everyday life. The first industrial initiative on food ionization dates back to 1956. In 1980, the Joint Expert Committee on Food Ionization concluded that food ionization up to a certain maximum dose presented neither toxicological nor nutritional hazard. This opened the new era for the industrial development. But in 1988, a draft directive to harmonize national legislations was issued by the Commission of European Communities. This stopped many industrial initiatives due to uncertainty. It is estimated that nearly 14,000 tons of various food items have been ionized in France in 1991. About 40% are spices, followed by dry fruit, vegetables, and deboned poultry meat. Most of the present applications are intended to eliminate microorganisms. In 1992, 8 industrial facilities were in operation, mostly using gamma sources. Local research associations were founded to promote food ionization. Food ionization development in the past 30 years has been rapid and important, but the future of this process depends on the European harmonization of legislations. (K.I.)

  10. Resonantly enhanced collisional ionization measurements of radionuclides

    International Nuclear Information System (INIS)

    Whitaker, T.J.; Bushaw, B.A.; Gerke, G.K.

    1986-01-01

    The authors developed a new laser technique to analyze for radionuclides at extremely low levels. The technique, called resonantly enhanced collisional ionization (RECI), uses two nitrogen-laser pumped dye lasers to excite the target isotope to a high-energy Rydberg state. Atoms in these Rydberg states (within a few hundred wavenumbers in energy from the ionization threshold) efficiently ionize upon colliding with an inert gas and the ions can be detected by conventional means. The principal advantage of resonantly-enhanced collisional ionization is the extreme sensitivity coupled with its relative simplicity and low cost. Actinides typically have an ionization potential of about 6eV (uranium I.P. = 6.2 eV, plutonium I.P. = 5.7 eV). Two-step laser excitation to a state just below threshold requires wavelengths in the blue region of the visible spectrum. They showed that when both steps in the excitation process are resonant steps, relatively low-power lasers can populate the Rydberg state with almost unit efficiency. This is because the resonant excitations have much larger cross-sections than do photoionization processes. They also demonstrated that a few torr of a buffer gas will cause most of the excited-state atoms to be ionized

  11. Characteristics of a Dry Fog Ionizer

    International Nuclear Information System (INIS)

    Murata, Y; Kudo, Y; Yonezawa, M

    2008-01-01

    The newly developed 'Dry Fog Ionizer' generates charged dry fog. The dry fog consists of very fine water droplets 8μm in mean diameter. This system consists of a dry fog nozzle (H.Ikeuchi and Co., LTD.), a ring electrode for induction charging (50mm outside diameter, and 10mm thick) in front of the nozzle, and a fan for dissipating charged dry fog. The ring electrode is DC or AC-biased and fine droplets ejected from the nozzle are electrified by induction charging. The particle size of the charged water droplets are reduced through evaporation during the transporting process by air flow, and completely evaporate approximately 2m from the nozzle under normal atmospheric conditions (25 deg. C, 60%R.H.) leaving high density ions. Using this system, high density ionic space charge can be realized in a remote spot from the ionizer. By this principle, the Dry Fog Ionizer shows strong charge-eliminating ability in the region away from the ionizer. When a dc bias of 5kV was applied to a ring electrode with the rate of water flow from the nozzle being 21/h, an ionic space-charge density of 1200nC /m 3 was able to be obtained at a distance 2m away from the ionizer, which was 10 2 times the value produced by an ordinary corona-type ionizer with an air blower.

  12. Comparison among different CT ionization chambers

    International Nuclear Information System (INIS)

    Castro, Maysa C. de; Xavier, Marcos; Caldas, Linda V.E.

    2015-01-01

    The dosimetry in computed tomography (CT) is carried out by the use of a pencil type ionization-chamber, because it has a uniform response at all angles relative to the incident beam of radiation, which is essential for CT equipment since the X-ray tube executes a circular movement around the table during irradiation. The commercial ionization chamber used to perform quality control procedures of this kind of equipment has a length of the sensitive volume of 10 cm. In the Calibration Laboratory of Instruments (LCI) of the IPEN there were already developed some prototypes with small differences in construction, when compared to commercially available ionization chambers. They have been used in previous studies and showed results within internationally acceptable limits. The ionization chambers tested in this study present the sensitive volume lengths of 1 cm, 3 cm and 10 cm. The objective of this study was to present results on the stability test of the three homemade ionization chambers and a commercial chamber, as well to obtain the calibration coefficients for each of them in CT standard X radiation beams. The obtained results for both characterization tests are within the recommended limits, except for the homemade ionization chambers with sensitive volume lengths of 3 cm and 1 cm in the case of the stability test. (author)

  13. Inner shell ionization accompanying nuclear collisions

    International Nuclear Information System (INIS)

    Sujkowski, Z.

    1987-01-01

    Selected phenomena leading to inner shell ionization and being of relevance for nuclear physics are discussed. The selection emphasizes the K-shell ionization induced in head-on collisions by fast light and medium-heavy ions. Cross-sections are reviewed. Effects of multiple inner shell ionization on the K X-ray spectra are illustrated with recent results. Implications for nuclear experiments are noted. Use of atomic observables as clocks for proton induced nuclear reactions is reviewed. Prospects for H.I. reactions are discussed. Preliminary experimental results on the direct K-shell ionization accompanying H.I. fusion reactions are presented. The post-collisional K-shell ionization due to internal conversion of γ-rays is discussed as the dominating contribution to the ionization for residues of dissipative nuclear reactions with Z > 40. Systematics of the corresponding K X-ray multiplicities are presented for rotational nuclei. These multiplicity values can be used for determining cross-sections for e.g. incomplete fusion reactions. Examples of such applications are given. Also discussed is the use of target K X-rays for normalization purposes and of the post-collisional, residue K X-rays in the studies of high spin phenomena. 96 references, 35 figures, 3 tables

  14. Microwave ionization of hydrogen atoms below the classical chaos border

    Energy Technology Data Exchange (ETDEWEB)

    Bluemel, R; Smilansky, U

    1987-01-01

    We present and discuss theoretical predictions for the occurrence of radiation induced ionization of hydrogen atoms in fields which are well below the classical ionization threshold. Strong ionization occurs due to enhanced population of a band of high n states which ionize easily. This enhancement happens only at rather narrowly defined field values, and is explained in terms of avoided crossings of Floquet levels.

  15. IONIZATION IN ATMOSPHERES OF BROWN DWARFS AND EXTRASOLAR PLANETS. V. ALFVÉN IONIZATION

    International Nuclear Information System (INIS)

    Stark, C. R.; Helling, Ch.; Rimmer, P. B.; Diver, D. A.

    2013-01-01

    Observations of continuous radio and sporadic X-ray emission from low-mass objects suggest they harbor localized plasmas in their atmospheric environments. For low-mass objects, the degree of thermal ionization is insufficient to qualify the ionized component as a plasma, posing the question: what ionization processes can efficiently produce the required plasma that is the source of the radiation? We propose Alfvén ionization as a mechanism for producing localized pockets of ionized gas in the atmosphere, having sufficient degrees of ionization (≥10 –7 ) that they constitute plasmas. We outline the criteria required for Alfvén ionization and demonstrate its applicability in the atmospheres of low-mass objects such as giant gas planets, brown dwarfs, and M dwarfs with both solar and sub-solar metallicities. We find that Alfvén ionization is most efficient at mid to low atmospheric pressures where a seed plasma is easier to magnetize and the pressure gradients needed to drive the required neutral flows are the smallest. For the model atmospheres considered, our results show that degrees of ionization of 10 –6 -1 can be obtained as a result of Alfvén ionization. Observable consequences include continuum bremsstrahlung emission, superimposed with spectral lines from the plasma ion species (e.g., He, Mg, H 2 , or CO lines). Forbidden lines are also expected from the metastable population. The presence of an atmospheric plasma opens the door to a multitude of plasma and chemical processes not yet considered in current atmospheric models. The occurrence of Alfvén ionization may also be applicable to other astrophysical environments such as protoplanetary disks

  16. Tissue macrophage activation: a shared sign of exposure to ionizing and non-ionizing radiation

    International Nuclear Information System (INIS)

    Petrenyov, D.R.

    2012-01-01

    The features of oxidative metabolism of peritoneal macrophages were studied in rats exposed to ionizing and non-ionizing radiation. An increased RNS and ROS production reported in animals exposed to both source of radiation showing non-specific response of organism. (authors)

  17. Mass spectrometry of solid samples in open air using combined laser ionization and ambient metastable ionization

    International Nuclear Information System (INIS)

    He, X.N.; Xie, Z.Q.; Gao, Y.; Hu, W.; Guo, L.B.; Jiang, L.; Lu, Y.F.

    2012-01-01

    Mass spectrometry of solid samples in open air was carried out using combined laser ionization and metastable ionization time-of-flight mass spectrometry (LI-MI-TOFMS) in ambient environment for qualitative and semiquantitative (relative analyte information, not absolute information) analysis. Ambient metastable ionization using a direct analysis in realtime (DART) ion source was combined with laser ionization time-of-flight mass spectrometry (LI-TOFMS) to study the effects of combining metastable and laser ionization. A series of metallic samples from the National Institute of Standards and Technology (NIST 494, 495, 498, 499, and 500) and a pure carbon target were characterized using LI-TOFMS in open air. LI-MI-TOFMS was found to be superior to laser-induced breakdown spectroscopy (LIBS). Laser pulse energies between 10 and 200 mJ at the second harmonic (532 nm) of an Nd:YAG laser were applied in the experiment to obtain a high degree of ionization in plasmas. Higher laser pulse energy improves signal intensities of trace elements (such as Fe, Cr, Mn, Ni, Ca, Al, and Ag). Data were analyzed by numerically calculating relative sensitivity coefficients (RSCs) and limit of detections (LODs) from mass spectrometry (MS) and LIBS spectra. Different parameters, such as boiling point, ionization potential, RSC, LOD, and atomic weight, were shown to analyze the ionization and MS detection processes in open air.

  18. Ionization mechanisms in capillary supercritical fluid chromatography-chemical ionization mass spectrometry

    NARCIS (Netherlands)

    Houben, R.J.; Leclercq, P.A.; Cramers, C.A.M.G.

    1991-01-01

    Ionization mechanisms have been studied for supercritical fluid chromatography (SFC) with mass spectrometric (MS) detection. One of the problems associated with SFC-MS is the interference of mobile phase constituents in the ionization process, which complicates the interpretation of the resulting

  19. Efficient ionizer for polarized H- formation

    International Nuclear Information System (INIS)

    Alessi, J.G.

    1985-01-01

    An ionizer is under development for a polarized H - source based on the resonant charge exchange reaction polarized H 0 + D - → polarized H - + D 0 . The polarized H 0 beam passes through the center of a magnetron surface-plasma source having an annular geometry, where it crosses a high current (approx.0.5 A), 200 eV D - beam. Calculations predict an H 0 → H - ionization efficiency of approx.7%, more than an order of magnitude higher than that obtained on present ground state atomic beam sources. In initial experiments using an unpolarized H 0 beam, H - currents in excess of 100 μA have been measured. While the ionization efficiency is now only about the same as other methods (Cs beam, for example), the results are encouraging since it appears that by injecting positive ions to improve the space-charge neutralization, and by improving the extraction optics, considerable gains in intensity will be made. We will then use this ionizer with a polarized H 0 beam, and measure the polarization of the resulting H - beam. If no depolarization is observed this ionizer will be combined with an atomic beam, cooled to 5 to 6 K, to give a polarized H - beam expected to be in the milliampere range for use in the AGS

  20. Pressing problems of measurement of ionizing radiations

    International Nuclear Information System (INIS)

    Fominykh, V.I.; Yudin, M.F.

    1993-01-01

    The current system for ensuring the unity of measurements in the Russian Federation and countries of the former Soviet Union ensures a high quality of dosimetric, radiometric, and spectrometric measurements in accordance with the recommendations of the Consulative Committee on Standards for Measurements of Ionizing Radiations of the International Bureau of Weights and Measures (IBWM), International Organization on Radiological Units (ICRU), International Commission on Radiological Protection (ICRP), International Organization on Legislative Metrology (IOLM), International Atomic Energy Agency (IAEA), World Health Organization (WHO), etc. Frequent collation of the national primary and secondary standards of Russia with those of IBWM and the leading national laboratories of the world facilitate mutual verification of the measurements of ionizing radiations. The scope of scientific and scientific-technical problems that can be solved by using ionizing radiations has expanded significantly in recent years. In this paper the authors consider some pressing problems of the metrology of ionizing radiations which have arisen as a result of this expansion. These include the need for unity and reliability of measurements involved in radiation protection, the measurement of low doses involving low dose rates, ensuring the unity of measurements when monitoring the radiological security of the population, the need for more uniformity on an international scale regarding the basic physical quantities and their units for characterizing radiation fields, determination of the accuracy of measurement of the radiation dose absorbed by an irradiated tissue or organ, and the development of complex standards for ionizing radiations. 5 refs., 1 tab

  1. The GBT Diffuse Ionized Gas Survey (GDIGS)

    Science.gov (United States)

    Luisi, Matteo; Anderson, Loren Dean; Liu, Bin; Bania, Thomas; Balser, Dana; Wenger, Trey; Haffner, Lawrence Matthew

    2018-01-01

    Diffuse ionized gas in the Galactic mid-plane known as the "Warm Ionized Medium" (WIM) makes up ~20% of the gas mass of the Milky Way and >90% of its ionized gas. It is the last major component of the interstellar medium (ISM) that has not yet been studied at high spatial and spectral resolution, and therefore many of its fundamental properties remain unclear. The Green Bank Telescope (GBT) Diffuse Ionized Gas Survey (GDIGS) is a new large survey of the Milky Way disk at C-band (4-8 GHz). The main goals of GDIGS are to investigate the properties of the WIM and to determine the connection between the WIM and high-mass star formation over the Galactic longitude and latitude range of 32 deg > l > -5 deg, |b| resolution of 0.5 km/s and rms sensitivities of ~3 mJy per beam. GDIGS observations are currently underway and are expected to be completed by late 2018. These data will allow us to: 1) Study for the first time the inner-Galaxy WIM unaffected by confusion from discrete HII regions, 2) determine the distribution of the inner Galaxy WIM, 3) investigate the ionization state of the WIM, 4) explore the connection between the WIM and HII regions, and 5) analyze the effect of leaked photons from HII regions on ISM dust temperatures.

  2. Surface ionization ion source with high current

    International Nuclear Information System (INIS)

    Fang Jinqing; Lin Zhizhou; Yu Lihua; Zhan Rongan; Huang Guojun; Wu Jianhua

    1986-04-01

    The working principle and structure of a surface ionization ion source with high current is described systematically. Some technological keypoints of the ion source are given in more detail, mainly including: choosing and shaping of the material of the surface ionizer, heating of the ionizer, distributing of working vapour on the ionizer surface, the flow control, the cooling problem at the non-ionization surface and the ion optics, etc. This ion source has been used since 1972 in the electromagnetic isotope separator with 180 deg angle. It is suitable for separating isotopes of alkali metals and rare earth metals. For instance, in the case of separating Rubidium, the maximum ion current of Rbsup(+) extracted from the ion source is about 120 mA, the maximum ion current accepted by the receiver is about 66 mA, the average ion current is more than 25 mA. The results show that our ion source have advantages of high ion current, good characteristics of focusing ion beam, working stability and structure reliability etc. It may be extended to other fields. Finally, some interesting phenomena in the experiment are disccused briefly. Some problems which should be investigated are further pointed out

  3. Conceptual basis of resonance ionization spectroscopy

    International Nuclear Information System (INIS)

    Payne, M.G.

    1984-04-01

    Resonance Ionization Spectroscopy (RIS) can b defined as a state-selective detection process in which tunable lasers are used to promote transitions from the selected state of the atoms or molecules in question to higher states, one of which will be ionized by the absorption of another photon. At least one resonance step is used in the stepwise ionization process, and it has been shown that the ionization probability of the spectroscopically selected species can nearly always be made close to unity. Since measurements of the number of photoelectrons or ions can be made very precisely and even one electron (or under vacuum conditions, one ion) can be detected, the technique can be used to make quantitative measurements of very small populations of the state-selected species. Counting of individual atoms has special meaning for detection of rare events. The ability to make saturated RIS measurements opens up a wide variety of applications to both basic and applied research. We view RIS as a specific type of multi-photon ionization in which the goal is to make quantitative measurements of quantum-selected populations in atomic or molecular systems. 16 references

  4. Recent attoclock measurements of strong field ionization

    International Nuclear Information System (INIS)

    Pfeiffer, Adrian N.; Cirelli, Claudio; Smolarski, Mathias; Keller, Ursula

    2013-01-01

    Highlights: ► The attoclock measures time by electron streaking with elliptically polarized light. ► Precision measurements reveal details about the laser-induced tunneling current flow. ► Multielectron effects play an important role when the polarizability is large. ► Double ionization experiments show evidence of novel electron correlation mechanisms. - Abstract: The attoclock is a powerful, new, and unconventional experimental tool to study fundamental attosecond dynamics on an atomic scale. We have demonstrated the first attoclock with the goal to measure the tunneling delay time in laser-induced ionization of helium and argon atoms, with surprising results. It was found that the time delay in tunneling is zero for helium and argon atoms within the experimental uncertainties of a few 10’s of attoseconds. Furthermore we showed that the single active electron approximation is not sufficient even for atoms such as argon and the parent-ion interaction is much more complex than normally assumed. For double ionization of argon we found again surprising results because the ionization time of the first electron is in good agreement with the predictions, whereas the ionization of the second electron occurs significantly earlier than predicted and the two electrons exhibit some unexpected correlation

  5. Recent attoclock measurements of strong field ionization

    Energy Technology Data Exchange (ETDEWEB)

    Pfeiffer, Adrian N., E-mail: apfeiff@phys.ethz.ch [Physics Department, ETH Zurich, 8093 Zurich (Switzerland); Cirelli, Claudio; Smolarski, Mathias; Keller, Ursula [Physics Department, ETH Zurich, 8093 Zurich (Switzerland)

    2013-03-12

    Highlights: ► The attoclock measures time by electron streaking with elliptically polarized light. ► Precision measurements reveal details about the laser-induced tunneling current flow. ► Multielectron effects play an important role when the polarizability is large. ► Double ionization experiments show evidence of novel electron correlation mechanisms. - Abstract: The attoclock is a powerful, new, and unconventional experimental tool to study fundamental attosecond dynamics on an atomic scale. We have demonstrated the first attoclock with the goal to measure the tunneling delay time in laser-induced ionization of helium and argon atoms, with surprising results. It was found that the time delay in tunneling is zero for helium and argon atoms within the experimental uncertainties of a few 10’s of attoseconds. Furthermore we showed that the single active electron approximation is not sufficient even for atoms such as argon and the parent-ion interaction is much more complex than normally assumed. For double ionization of argon we found again surprising results because the ionization time of the first electron is in good agreement with the predictions, whereas the ionization of the second electron occurs significantly earlier than predicted and the two electrons exhibit some unexpected correlation.

  6. Deep-down ionization of protoplanetary discs

    Science.gov (United States)

    Glassgold, A. E.; Lizano, S.; Galli, D.

    2017-12-01

    The possible occurrence of dead zones in protoplanetary discs subject to the magneto-rotational instability highlights the importance of disc ionization. We present a closed-form theory for the deep-down ionization by X-rays at depths below the disc surface dominated by far-ultraviolet radiation. Simple analytic solutions are given for the major ion classes, electrons, atomic ions, molecular ions and negatively charged grains. In addition to the formation of molecular ions by X-ray ionization of H2 and their destruction by dissociative recombination, several key processes that operate in this region are included, e.g. charge exchange of molecular ions and neutral atoms and destruction of ions by grains. Over much of the inner disc, the vertical decrease in ionization with depth into the disc is described by simple power laws, which can easily be included in more detailed modelling of magnetized discs. The new ionization theory is used to illustrate the non-ideal magnetohydrodynamic effects of Ohmic, Hall and Ambipolar diffusion for a magnetic model of a T Tauri star disc using the appropriate Elsasser numbers.

  7. Electron-impact ionization of Mo+

    International Nuclear Information System (INIS)

    Ludlow, J.A.; Loch, S.D.; Pindzola, M.S.

    2005-01-01

    The electron-impact direct ionization cross section for Mo + is calculated using both nonperturbative close-coupling and perturbative distorted-wave methods. When distorted-wave calculations for 4d 5 →4d 4 direct ionization are added to distorted-wave calculations for 4p→nl excitation-autoionization, the experimental measurements are found to be 60% lower than the theoretical predictions. Inclusion of nonperturbative three-body Coulomb effects, present in time-dependent close-coupling calculations, are found to reduce the distorted-wave 4d 5 →4d 4 direct ionization cross section by 25%. This is by far the largest reduction yet seen when comparing the two methods for direct subshell ionization of an atomic positive ion in the ground state. However, when the close-coupling calculations for 4d 5 →4d 4 direct ionization are added to distorted-wave calculations for 4p→nl excitation-autoionization, the experimental measurements are still 45% lower than the theoretical predictions. Although we further investigate correlation effects in the initial target state and term-dependent potential effects in the ejected electron state in an attempt to understand the small magnitude of the experimental measurements, the discrepancy between theory and experiment remains unexplained

  8. Multiple ionization and coupling effects in L-subshell ionization of heavy atoms by oxygen ions

    International Nuclear Information System (INIS)

    Pajek, M.; Banas, D.; Semaniak, J.; Braziewicz, J.; Majewska, U.; Chojnacki, S.; Czyzewski, T.; Fijal, I.; Jaskola, M.; Glombik, A.; Kretschmer, W.; Trautmann, D.; Lapicki, G.; Mukoyama, T.

    2003-01-01

    The multiple-ionization and coupling effects in L-shell ionization of atoms by heavy-ion impact have been studied by measuring the L x-ray production cross sections in solid targets of Au, Bi, Th, and U bombarded by oxygen ions in the energy range 6.4-70 MeV. The measured L x-ray spectra were analyzed using the recently proposed method accounting for the multiple-ionization effects, such as x-ray line shifting and broadening, which enables one to obtain the ionization probabilities for outer shells. The L-subshell ionization cross sections have been obtained from measured x-ray production cross sections for resolved Lα 1,2 , Lγ 1 , and Lγ 2,3 transitions using the L-shell fluorescence and Coster-Kronig yields being substantially modified by the multiple ionization in the M and N shells. In particular, the effect of closing of strong L 1 -L 3 M 4,5 Coster-Kronig transitions in multiple-ionized atoms was evidenced and discussed. The experimental ionization cross sections for the L 1 , L 2 , and L 3 subshells have been compared with the predictions of the semiclassical approximation (SCA) and the ECPSSR theory that includes the corrections for the binding-polarization effect within the perturbed stationary states approximation, the projecticle energy loss, and Coulomb deflection effects as well as the relativistic description of inner-shell electrons. These approaches were further modified to include the L-subshell couplings within the ''coupled-subshell model'' (CSM). Both approaches, when modified for the coupling effects, are in better agreement with the data. Particularly, the predictions of the SCA-CSM calculations reproduce the experimental L-subshell ionization cross section reasonably well. Remaining discrepancies are discussed qualitatively, in terms of further modifications of the L-shell decay rates caused by a change of electronic wave functions in multiple-ionized atoms

  9. Ionizing radiation and genetic risks

    Energy Technology Data Exchange (ETDEWEB)

    Sankaranarayanan, K. [Department of Toxicogenetics, Leiden University Medical Centre, Sylvius Laboratories, Wassenaarseweg 72, 2333 AL Leiden (Netherlands)]. E-mail: sankaran@lumc.nl; Wassom, J.S. [YAHSGS, LLC, Richland, WA 99352 (United States); Life Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37830 (United States)

    2005-10-15

    Recent estimates of genetic risks from exposure of human populations to ionizing radiation are those presented in the 2001 report of the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). These estimates incorporate two important concepts, namely, the following: (1) most radiation-induced mutations are DNA deletions, often encompassing multiple genes, but only a small proportion of the induced deletions is compatible with offspring viability; and (2) the viability-compatible deletions induced in germ cells are more likely to manifest themselves as multi-system developmental anomalies rather than as single gene disorders. This paper: (a) pursues these concepts further in the light of knowledge of mechanisms of origin of deletions and other rearrangements from two fields of contemporary research: repair of radiation-induced DNA double-strand breaks (DSBs) in mammalian somatic cells and human molecular genetics; and (b) extends them to deletions induced in the germ cell stages of importance for radiation risk estimation, namely, stem cell spermatogonia in males and oocytes in females. DSB repair studies in somatic cells have elucidated the roles of two mechanistically distinct pathways, namely, homologous recombination repair (HRR) that utilizes extensive sequence homology and non-homologous end-joining (NHEJ) that requires little or no homology at the junctions. A third process, single-strand annealing (SSA), which utilizes short direct repeat sequences, is considered a variant of HRR. HRR is most efficient in late S and G{sub 2} phases of the cell cycle and is a high fidelity mechanism. NHEJ operates in all cell cycle phases, but is especially important in G{sub 1}. In the context of radiation-induced DSBs, NHEJ is error-prone. SSA is also an error-prone mechanism and its role is presumably similar to that of HRR. Studies in human molecular genetics have demonstrated that the occurrence of large deletions, duplications or other

  10. Ionizing radiation and genetic risks

    International Nuclear Information System (INIS)

    Sankaranarayanan, K.; Wassom, J.S.

    2005-01-01

    Recent estimates of genetic risks from exposure of human populations to ionizing radiation are those presented in the 2001 report of the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). These estimates incorporate two important concepts, namely, the following: (1) most radiation-induced mutations are DNA deletions, often encompassing multiple genes, but only a small proportion of the induced deletions is compatible with offspring viability; and (2) the viability-compatible deletions induced in germ cells are more likely to manifest themselves as multi-system developmental anomalies rather than as single gene disorders. This paper: (a) pursues these concepts further in the light of knowledge of mechanisms of origin of deletions and other rearrangements from two fields of contemporary research: repair of radiation-induced DNA double-strand breaks (DSBs) in mammalian somatic cells and human molecular genetics; and (b) extends them to deletions induced in the germ cell stages of importance for radiation risk estimation, namely, stem cell spermatogonia in males and oocytes in females. DSB repair studies in somatic cells have elucidated the roles of two mechanistically distinct pathways, namely, homologous recombination repair (HRR) that utilizes extensive sequence homology and non-homologous end-joining (NHEJ) that requires little or no homology at the junctions. A third process, single-strand annealing (SSA), which utilizes short direct repeat sequences, is considered a variant of HRR. HRR is most efficient in late S and G 2 phases of the cell cycle and is a high fidelity mechanism. NHEJ operates in all cell cycle phases, but is especially important in G 1 . In the context of radiation-induced DSBs, NHEJ is error-prone. SSA is also an error-prone mechanism and its role is presumably similar to that of HRR. Studies in human molecular genetics have demonstrated that the occurrence of large deletions, duplications or other rearrangements

  11. Code of practice for ionizing radiation

    International Nuclear Information System (INIS)

    Khoo Boo Huat

    1995-01-01

    Prior to 1984, the use of ionizing radiation in Malaysia was governed by the Radioactive Substances Act of 1968. After 1984, its use came under the control of Act 304, called the Atomic Energy Licensing Act 1984. Under powers vested by the Act, the Radiation Protection (Basic Safety Standards) Regulations 1988 were formulated to regulate its use. These Acts do not provide information on proper working procedures. With the publication of the codes of Practice by The Standards and Industrial Research Institute of Malaysia (SIRIM), the users are now able to follow proper guidelines and use ionizing radiation safely and beneficially. This paper discusses the relevant sections in the following codes: 1. Code of Practice for Radiation Protection (Medical X-ray Diagnosis) MS 838:1983. 2. Code of Practice for Safety in Laboratories Part 4: Ionizing radiation MS 1042: Part 4: 1992. (author)

  12. Method and apparatus for analyzing ionizable materials

    International Nuclear Information System (INIS)

    Ehrlich, B.J.; Hall, R.C.; Thiede, P.W.

    1979-01-01

    An apparatus and method are described for analyzing a solution of ionizable compounds in a liquid. The solution is irradiated with electromagnetic radiation to ionize the compounds and the electrical conductivity of the solution is measured. The radiation may be X-rays, ultra-violet, infra-red or microwaves. The solution may be split into two streams, only one of which is irradiated, the other being used as a reference by comparing conductivities of the two streams. The liquid must be nonionizable and is preferably a polar solvent. The invention provides an analysis technique useful in liquid chromatography and in gas chromatography after dissolving the eluted gases in a suitable solvent. Electrical conductivity measurements performed on the irradiated eluent provide a quantitative indication of the ionizable materials existing within the eluent stream and a qualitative indication of the purity of the eluent stream. (author)

  13. Ionizing radiation and wild birds: a review

    International Nuclear Information System (INIS)

    Mellinger, P.J.; Schultz, V.

    1975-01-01

    Since the first atomic explosion, 16 July 1945 at the Trinity Site in south-central New Mexico, the impact of ionizing radiation on bird populations has been of concern to a few individuals. The proliferation of nuclear power plants has increased public concern as to possible deleterious effects of nuclear power plant operation on resident and migratory bird populations. Literature involving wild birds and ionizing radiation is not readily available, and only a few studies have been anywhere near comprehensive, with most effort directed towards monitoring radionuclide concentration in birds. The objective of the paper is to document the literature on wild birds and ionizing radiation including a brief description of pertinent papers

  14. Radiation ionization is an underestimated industrial technique

    International Nuclear Information System (INIS)

    Anon.

    1999-01-01

    Industrial radiation ionization requires electron beams coming from an accelerator or gamma radiation from a radioactive source (Co 60 ). The energy deposed in the irradiated material modifies its chemical bounds or kills micro-organisms. This process is used in medical material sterilization, in disinfestation of stored and packaged food products, in the production of plastic, in the coloring of glass, in the hardening of electronic components and in the modification of the properties of semi-conductors. For 40 years radiation ionization has been investigated, UNO (United Nations Organization) and WHO (World Health Organisation) recommend it for food processing. With a growing rate of 15% per year for the last 15 years, radiation ionization is now widely used. More than 170 gamma irradiation facilities are operating throughout the world. (A.C.)

  15. Multiphoton ionization/dissociation of osmium tetroxide

    International Nuclear Information System (INIS)

    Ding, D.; Puretzky, A.A.; Compton, R.N.

    1993-01-01

    The mechanisms leading to laser multiphoton ionization and dissociation (MPI/MPD) of osmium tetroxide (OsO 4 ) have been investigated from measurements of the kinetic energies of product ions (Os + , Os 2+ , OsO + , O 2 + , O + ) and photoelectrons as a function of the laser wavelength. Neutral channels, intermediate to the dominant Os + ionization channel, such as OsO 4 →OsO 4-n +nO are examined using resonance-enhanced multiphoton ionization (REMPI) of the fast O atoms. Equipartition of the available photon energy among the fragments is observed. The wavelength dependence of the Os + ion signal suggests that one or more of the steps leading to Os + ions involve molecular ions and/or excited neutral atoms. The observed preponderance of very slow ( 2+ is shown to result primarily from REMPI of Os +

  16. Ionizing radiation effects on floating gates

    International Nuclear Information System (INIS)

    Cellere, G.; Paccagnella, A.; Visconti, A.; Bonanomi, M.

    2004-01-01

    Floating gate (FG) memories, and in particular Flash, are the dominant among modern nonvolatile memory technologies. Their performance under ionizing radiation was traditionally studied for the use in space, but has become of general interest in recent years. We are showing results on the charge loss from programmed FG arrays after 10 keV x-rays exposure. Exposure to ionizing radiation results in progressive discharge of the FG. More advanced devices, featuring smaller FG, are less sensitive to ionizing radiation that older ones. The reason is identified in the photoemission of electrons from FG, since at high doses it dominates over charge loss deriving from electron/hole pairs generation in the oxides

  17. Memory in Nonlinear Ionization of Transparent Solids

    International Nuclear Information System (INIS)

    Rajeev, P. P.; Simova, E.; Hnatovsky, C.; Taylor, R. S.; Rayner, D. M.; Corkum, P. B.; Gertsvolf, M.; Bhardwaj, V. R.

    2006-01-01

    We demonstrate a shot-to-shot reduction in the threshold laser intensity for ionization of bulk glasses illuminated by intense femtosecond pulses. For SiO 2 the threshold change serves as positive feedback reenforcing the process that produced it. This constitutes a memory in nonlinear ionization of the material. The threshold change saturates with the number of pulses incident at a given spot. Irrespective of the pulse energy, the magnitude of the saturated threshold change is constant (∼20%). However, the number of shots required to reach saturation does depend on the pulse energy. Recognition of a memory in ionization is vital to understand multishot optical or electrical breakdown phenomena in dielectrics

  18. Progress in zirconium resonance ionization spectroscopy

    International Nuclear Information System (INIS)

    Page, R.H.; Dropinski, S.C.; Worden, E.F.; Stockdale, J.A.D.

    1993-01-01

    The authors have examined the stepwise-resonant three-photon-ionization spectrum of neutral zirconium atoms using three separately-tunable pulsed visible dye lasers. The ground-level (first-step) transitions were chosen on the basis of demonstrated 91 Zr selectivity. Lifetimes of even-parity levels around 36,000 cm -1 , measured with the delayed-photoionization technique, range from 10 to 100 nsec. Direct ionization cross sections appear to be less than 10 -17 cm 2 ; newly-detected autoionizing levels give peak ionization cross sections (inferred from saturation fluences) up to 10 -15 cm 2 . Portions of Rydberg series converging to the 315 and 763 cm -1 levels of Zr + were identified. Clumps of autoionizing levels are thought to be due to Rydberg-valence mixing

  19. Protection policies for ionizing and UV radiation

    International Nuclear Information System (INIS)

    Bosnjakovic, B.F.M.

    1987-01-01

    Although ultraviolet radiation is generally considered as being part of non-ionizing radiation, the existing similarities with ionizing radiation are too striking to be overseen. A comparison of these two agents is becoming important in view of the increasing awareness of various environmental and health risks and the tendency to develop more uniform risk management policies with respect to the different physical and chemical agents. This paper explores the similarities and differences of UV and ionizing radiation from the point of view of policies either adopted or in development. Policy determinants include, among others, the following factors: biological effects, dosimetric quantities, relative contribution to exposure from different sources, hazard potential of different sources, quantification of detrimental consequences, public perception of the radiation hazards and regulation developments. These factors are discussed

  20. Ionizing radiation interactions with DNA: nanodosimetry

    International Nuclear Information System (INIS)

    Bug, Marion; Nettelbeck, Heidi; Hilgers, Gerhard; Rabus, Hans

    2011-01-01

    The metrology of ionizing radiation is based on measuring values that are averaged over macroscopic volume elements, for instance the energy dose is defined as ratio of the energy deposited on the absorber and the absorber mass. For biological or medical radiation effects the stochastic nature of radiation interaction id of main importance, esp. the interaction of ionizing radiation with the DNA as the genetic information carrier. For radiotherapy and risk evaluation purposes a comprehensive system of radiation weighing factors and other characteristics, like radiation quality or relative biological efficacy was developed. The nanodosimetry is aimed to develop a metrological basis relying on physical characteristics of the microscopic structure of ionizing radiation tracks. The article includes the development of experimental nanodosimetric methods, the respective calibration techniques, Monte-Carlo simulation of the particle track microstructure and the correlation nanodosimetry and biological efficiency.

  1. Guided ionization waves: Theory and experiments

    International Nuclear Information System (INIS)

    Lu, X.; Naidis, G.V.; Laroussi, M.; Ostrikov, K.

    2014-01-01

    This review focuses on one of the fundamental phenomena that occur upon application of sufficiently strong electric fields to gases, namely the formation and propagation of ionization waves–streamers. The dynamics of streamers is controlled by strongly nonlinear coupling, in localized streamer tip regions, between enhanced (due to charge separation) electric field and ionization and transport of charged species in the enhanced field. Streamers appear in nature (as initial stages of sparks and lightning, as huge structures—sprites above thunderclouds), and are also found in numerous technological applications of electrical discharges. Here we discuss the fundamental physics of the guided streamer-like structures—plasma bullets which are produced in cold atmospheric-pressure plasma jets. Plasma bullets are guided ionization waves moving in a thin column of a jet of plasma forming gases (e.g., He or Ar) expanding into ambient air. In contrast to streamers in a free (unbounded) space that propagate in a stochastic manner and often branch, guided ionization waves are repetitive and highly-reproducible and propagate along the same path—the jet axis. This property of guided streamers, in comparison with streamers in a free space, enables many advanced time-resolved experimental studies of ionization waves with nanosecond precision. In particular, experimental studies on manipulation of streamers by external electric fields and streamer interactions are critically examined. This review also introduces the basic theories and recent advances on the experimental and computational studies of guided streamers, in particular related to the propagation dynamics of ionization waves and the various parameters of relevance to plasma streamers. This knowledge is very useful to optimize the efficacy of applications of plasma streamer discharges in various fields ranging from health care and medicine to materials science and nanotechnology

  2. A prototype ionization profile monitor for RHIC

    International Nuclear Information System (INIS)

    Connolly, R.; Cameron, P.; Ryan, W.

    1997-01-01

    Transverse beam profiles in the Relativistic Heavy-Ion Collider (RHIC) will be measured with ionization profile monitors (IPM's). Each IPM collects and measures the distribution of electrons in the beamline resulting from residual gas ionization during bunch passage. The electrons are swept transversely from the beamline and collected on strip anodes oriented parallel to the beam axis. At each bunch passage the charge pulses are amplified, integrated, and digitized for display as a profile histogram. A prototype detector was tested in the injection line during the RHIC Sextant Test. This paper describes the detector and gives results from the beam tests

  3. Effect of ionizing radiations on connective tissue

    International Nuclear Information System (INIS)

    Altman, K.I.; Gerber, G.B.

    1980-01-01

    The effects of ionizing radiations on connective tissue in lung, heart, vasculature, kidney, skin, and skeletal tissues are reviewed. Special emphasis is given to the effect of ionizing radiations on vasculo-connective tissue and fibrotic changes following radiation-induced injury to organs and tissues. In order to put the subject matter in proper prospective, the general biochemistry, physiology, and pathology of connective tissue is reviewed briefly together with the participation of connective tissue in disease. The review closes with an assessment of future problems and an enumeration and discussion of important, as yet unanswered questions

  4. The Muon Ionization Cooling Experiment User Software

    Science.gov (United States)

    Dobbs, A.; Rajaram, D.; MICE Collaboration

    2017-10-01

    The Muon Ionization Cooling Experiment (MICE) is a proof-of-principle experiment designed to demonstrate muon ionization cooling for the first time. MICE is currently on Step IV of its data taking programme, where transverse emittance reduction will be demonstrated. The MICE Analysis User Software (MAUS) is the reconstruction, simulation and analysis framework for the MICE experiment. MAUS is used for both offline data analysis and fast online data reconstruction and visualization to serve MICE data taking. This paper provides an introduction to MAUS, describing the central Python and C++ based framework, the data structure and and the code management and testing procedures.

  5. Generalized Bessel functions in tunnelling ionization

    International Nuclear Information System (INIS)

    Reiss, H R; Krainov, V P

    2003-01-01

    We develop two new approximations for the generalized Bessel function that frequently arises in the analytical treatment of strong-field processes, especially in non-perturbative multiphoton ionization theories. Both these new forms are applicable to the tunnelling environment in atomic ionization, and are analytically much simpler than the currently used low-frequency asymptotic approximation for the generalized Bessel function. The second of the new forms is an approximation to the first, and it is the second new form that exhibits the well-known tunnelling exponential

  6. Electron Impact Ionization of C60

    International Nuclear Information System (INIS)

    Duenser, B.; Lezius, M.; Scheier, P.; Deutsch, H.; Maerk, T.D.

    1995-01-01

    Absolute partial and total cross sections for the electron impact ionization of C 60 have been measured using a novel approach for the absolute calibration. The results obtained reveal not only an anomalous large parent ion cross section (as compared to the other ionization channels), but also anomalies for the production of multiply charged parent and fragment ions. This special behavior has its origin in the specific electronic and geometric structure of C 60 . Semiclassical calculations for singly charged ions support the measured data

  7. Effects of low doses of ionizing radiation

    International Nuclear Information System (INIS)

    Anon.

    2008-01-01

    Ionizing radiation of cosmic or terrestrial origin is part of the environment in which all living things have evolved since the creation of the universe. The artificial radioactivity generated by medical diagnostic and treatment techniques, some industrial activities, radioactive fallout, etc. has now been added to this natural radioactivity. This article reviews the biological effects of the low doses of ionizing radiation to which the population is thus exposed. Their carcinogenic risk cannot simply be extrapolated from what we know about high-dose exposure. (author)

  8. Electron induced atomic inner-shell ionization

    International Nuclear Information System (INIS)

    Quarles, C.A.

    1974-01-01

    The current status of cross section measurements for atomic inner-shell ionization by electron bombardment is reviewed. Inner shell ionization studies using electrons as projectiles compliment the similar studies being done with heavy particles, and in addition can provide tests of the theory in those cases when relativistic effects and exchange effects are expected to be important. Both total cross sections and recently measured differential cross sections will be discussed and compared with existing theories where possible. Prospects for further experimental and theoretical work in this area of atomic physics using small electron accelerators will also be discussed

  9. Ionization of atoms by high energy photons

    International Nuclear Information System (INIS)

    Amusia, M.Y.; Ioffe, A.F.

    1994-01-01

    Photoionization of atoms by high energy photons is considered. It is emphasized that in this frequency region the cross section and other characteristics of the process are strongly effected by electron shell polarization and rearrangement effects, including that due to inner vacancy Auger decay. In the effects of nuclear structure could be important and noticeable, i.e. of virtual or real excitation of the nucleus degrees of freedom and of the Quantum Electrodynamics vacuum. Ionization accompanied by secondary photon emission (Compton ionization) is analyzed in the considered domain of energies

  10. Ionizing radiation decreases human cancer mortality rates

    International Nuclear Information System (INIS)

    Luckey, T.D.

    1997-01-01

    Information from nine studies with exposed nuclear workers and military observers of atmospheric bomb explosions confirms the results from animal studies which showed that low doses of ionizing radiation are beneficial. The usual ''healthy worker effect'' was eliminated by using carefully selected control populations. The results from 13 million person-years show the cancer mortality rate of exposed persons is only 65.6% that of carefully selected unexposed controls. This overwhelming evidence makes it politically untenable and morally wrong to withhold public health benefits of low dose irradiation. Safe supplementation of ionizing radiation should become a public health service. (author)

  11. Direct Simulation of Reentry Flows with Ionization

    Science.gov (United States)

    Carlson, Ann B.; Hassan, H. A.

    1989-01-01

    The Direct Simulation Monte Carlo (DSMC) method is applied in this paper to the study of rarefied, hypersonic, reentry flows. The assumptions and simplifications involved with the treatment of ionization, free electrons and the electric field are investigated. A new method is presented for the calculation of the electric field and handling of charged particles with DSMC. In addition, a two-step model for electron impact ionization is implemented. The flow field representing a 10 km/sec shock at an altitude of 65 km is calculated. The effects of the new modeling techniques on the calculation results are presented and discussed.

  12. Saha's ionization equation for high Z elements

    International Nuclear Information System (INIS)

    Godwal, B.K.; Sikka, S.K.

    1977-01-01

    Saha's ionization equation has been solved for high Z elements with the aim of providing input for opacity calculations. Results are presented for two elements, tungsten and uranium. The ionization potentials have been evaluated using the simple Bhor's formula with suitable effective charges for ions. The reliability of the free electron density, ion concentrations, etc., obtained from the Saha's equation solutions has been checked by comparing the P and E computed from them with those given by the Thomas-Fermi-Dirac equation of state. The agreement between the two is good from temperatures above 0.2 keV. (author)

  13. A statistical mechanical model for equilibrium ionization

    International Nuclear Information System (INIS)

    Macris, N.; Martin, P.A.; Pule, J.

    1990-01-01

    A quantum electron interacts with a classical gas of hard spheres and is in thermal equilibrium with it. The interaction is attractive and the electron can form a bound state with the classical particles. It is rigorously shown that in a well defined low density and low temperature limit, the ionization probability for the electron tends to the value predicted by the Saha formula for thermal ionization. In this regime, the electron is found to be in a statistical mixture of a bound and a free state. (orig.)

  14. Surface ionization mass spectrometry of opiates

    International Nuclear Information System (INIS)

    Usmanov, D.T.

    2009-07-01

    Key words: surface ionization, adsorption, heterogeneous reactions, surface ionization mass spectrometry, thermodesorption surface ionization spectroscopy, thermoemitter, opiates, extracts of biosamples. Subjects of study. The mass - spectrometric study of thermal - ion emission: surface ionization of opiates by on the surface of oxidized refractory metals. Purpose of work is to establish the regularities of surface ionization (SI) of multi-atomic molecule opiates and their mixtures develop the scientific base of SI methods for high sensitive and selective detection and analysis of these substances in the different objects, including biosamples. Methods of study: surface ionization mass spectrometry, thermodesorption surface ionization spectroscopy. The results obtained and their novelty. For the first time, SI of molecule opiates on the oxidized tungsten surface has been studied and their SI mass-spectra and temperature dependences of ion currents have been obtained, the characteristic heterogeneous reactions of an adsorbed molecules and the channels of monomolecular decays vibrationally-excited ions on their way in mass-spectrometry have been revealed, sublimation energy has been defined, the activation energy of E act , of these decays has been estimated for given period of time. Additivity of the SI mass-spectra of opiate mixtures of has been established under conditions of joint opiate adsorption. High selectivity of SI allows the extracts of biosamples to be analyzed without their preliminary chromatographic separation. The opiates are ionized by SI with high efficiency (from 34 C/mol to 112 C/mol), which provides high sensitivity of opiate detection by SI/MS and APTDSIS methods from - 10 -11 g in the samples under analysis. Practical value. The results of these studies create the scientific base for novel SI methods of high sensitive detection and analysis of the trace amounts of opiates in complicated mixtures, including biosamples without their preliminary

  15. The situation of knowledge on ionizing radiation

    International Nuclear Information System (INIS)

    2005-01-01

    Occupational exposure to ionizing radiation occurs: during sources use, during the use of matter including radioactivity used for other properties than their radioactivity, in presence of natural radioactivity on the working area, following an accident during an industrial process. to protect man taken into account the incurred risk, goes by the risk evaluation, in taking into account the industrial process and exposure conditions of persons, then by the application of prevention measures that aim to control the contamination risks by radioactive matters as well as the exposure risks to ionizing radiations. (N.C.)

  16. Ionizing radiation environment for the TOMS mission

    Science.gov (United States)

    Lauriente, M.; Maloy, J. O.; Vampola, A. L.

    1992-01-01

    The Total Ozone Mapping Spectrometer (TOMS) will fly on several different spacecraft, each having an orbit which is approximately polar and 800-980 km in altitude. A description is given of the computer-based tools used for characterizing the spacecraft interactions with the ionizing radiation environment in orbit and the susceptibility requirements for ionizing radiation compatibility. The peak flux from the model was used to derive the expected radiation-induced noise in the South Atlantic Anomaly for the new TOMS instruments intended to fly on Advanced Earth Observatory System and Earth Probe.

  17. Ionization smoke detector and alarm system

    International Nuclear Information System (INIS)

    1974-01-01

    An ionization smoke detector particularly suited to residential use is disclosed. The detector is battery-operated and is connected with a non-latching, pulsating alarm circuit. The detector has a sensing chamber formed by a perforated metallic shell and an electrode within which an insulated radiation source is centrally positioned to generate an ionization current for detecting smoke or other similar aerosols. The alarm circuit provides a pulsating alarm signal when smoke levels above a pre-determined value are sensed. The alarm circuit also includes a low voltage detection circuit for sounding the alarm when the end of useful battery life is approaching. (Auth.)

  18. A prototype ionization profile monitor for RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Connolly, R.; Cameron, P.; Ryan, W. [and others

    1997-07-01

    Transverse beam profiles in the Relativistic Heavy-Ion Collider (RHIC) will be measured with ionization profile monitors (IPM`s). Each IPM collects and measures the distribution of electrons in the beamline resulting from residual gas ionization during bunch passage. The electrons are swept transversely from the beamline and collected on strip anodes oriented parallel to the beam axis. At each bunch passage the charge pulses are amplified, integrated, and digitized for display as a profile histogram. A prototype detector was tested in the injection line during the RHIC Sextant Test. This paper describes the detector and gives results from the beam tests.

  19. Simulation study of the ionizing front in the critical ionization velocity phenomenon

    International Nuclear Information System (INIS)

    Machida, S.; Goertz, C.K.; Lu, G.

    1988-01-01

    Simulations of the Critical Ionization Velocity (CIV) for a neutral gas cloud moving across the static magnetic field are made. We treat a low-β plasma and use a 2-1/2 D electrostatic code linked with our Plasma and Neutral Interaction Code (PANIC). Our study is focused on the understanding of the interface between the neutral gas cloud and the surrounding plasma where the strong interaction takes place. We assume the existence of some hot electrons in the ambient plasma to provide a seed ionization for CIV. When the ionization starts a sheath-like structure is formed at the surface of the neutral gas (Ionizing Front). In that region the crossfield component of the electric field causes the electron to E x B drift with a velocity of the order of the neutral gas velocity times the square root of the ion to electron mass ratio. Thus the kinetic energy of the drifting electrons can be large enough for electron impact ionization. In addition a diamagnetic drift of the electron occurs due to the number density and temperature inhomogeneity in the ionization front. These drift currents excite the lower-hybrid waves with the wave k-vectors almost perpendicular to the neutral flow and magnetic field again resulting in electron heating and additional ionization. The overall structure is studied by developing a simple analytic model as well as making simulation runs. (author)

  20. Chemical data on ionizing and non-ionizing angiographic contrast materials

    International Nuclear Information System (INIS)

    Bonati, F.

    1980-01-01

    The cardiovascular effects of ionizing and non-ionizing contrast media are compared in experimental animals and in isolated heart preparations. The following parameters were recorded: peripheric arterial diastolic pressure, heart rate, duration of asystolic period, respiratory rate, contractility of the myocardium (dp/dt, LVSP, Vsub(max), EDV, ESV, SV). The observed changes are mainly due to the higher osmotic activity of the contrast media, as similar alterations were recorded after the injection of hyperosmotic glucose solution. It is concluded that administration of non-ionizing contrast media results in significantly less cardiovascular side effects. (L.E.)

  1. New ionization fractions for the lithium- and helium-like ionization stages of calcium and iron

    International Nuclear Information System (INIS)

    Doyle, J.G.; Raymond, J.C.

    1981-01-01

    The high resolution X-ray spectra of Ca XIX and Fe XXV observed during a solar flare on 1979 March 25 have been re-interpreted using new ionization fractions for Ca XVIII, Ca XIX, Fe XXIV and Fe XXV. These new calculations substantially change the interpretation of the spectra, implying the flare to be ionizing during the rise phase and recombining during the decay phase. The results favour the ECIP ionization rates over those of Lotz, though other interpretations are possible. (author)

  2. Electrospray ionization and matrix assisted laser desorption/ionization mass spectrometry: powerful analytical tools in recombinant protein chemistry

    DEFF Research Database (Denmark)

    Andersen, Jens S.; Svensson, B; Roepstorff, P

    1996-01-01

    Electrospray ionization and matrix assisted laser desorption/ionization are effective ionization methods for mass spectrometry of biomolecules. Here we describe the capabilities of these methods for peptide and protein characterization in biotechnology. An integrated analytical strategy is presen......Electrospray ionization and matrix assisted laser desorption/ionization are effective ionization methods for mass spectrometry of biomolecules. Here we describe the capabilities of these methods for peptide and protein characterization in biotechnology. An integrated analytical strategy...... is presented encompassing protein characterization prior to and after cloning of the corresponding gene....

  3. Fluctuation charge effects in ionization fronts

    International Nuclear Information System (INIS)

    Arrayas, Manuel; Trueba, Jose L; Baltanas, J P

    2008-01-01

    In this paper, we study the effects of charge fluctuations on the propagation of both negative and positive ionization fronts in streamer discharges. We show that fronts accelerate when random charge creation events are present. This effect might play a similar role to photoionization in order to make the front move faster

  4. Fluctuation charge effects in ionization fronts

    Energy Technology Data Exchange (ETDEWEB)

    Arrayas, Manuel; Trueba, Jose L [Area de Electromagnetismo, Universidad Rey Juan Carlos, Camino del Molino s/n, 28943 Fuenlabrada, Madrid (Spain); Baltanas, J P [Departamento de Fisica Aplicada II, Universidad de Sevilla, Av. Reina Mercedes 2, 41012 Sevilla (Spain)

    2008-05-21

    In this paper, we study the effects of charge fluctuations on the propagation of both negative and positive ionization fronts in streamer discharges. We show that fronts accelerate when random charge creation events are present. This effect might play a similar role to photoionization in order to make the front move faster.

  5. Properties of Excitons Bound to Ionized Donors

    DEFF Research Database (Denmark)

    Skettrup, Torben; Suffczynski, M.; Gorzkowski, W.

    1971-01-01

    Binding energies, interparticle distances, oscillator strengths, and exchange corrections are calculated for the three-particle complex corresponding to an exciton bound to an ionized donor. The results are given as functions of the mass ratio of the electron and hole. Binding of the complex is o...

  6. Liquid-filled ionization chamber temperature dependence

    Energy Technology Data Exchange (ETDEWEB)

    Franco, L. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)]. E-mail: luciaff@usc.es; Gomez, F. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Iglesias, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pardo, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pazos, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pena, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Zapata, M. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)

    2006-05-10

    Temperature and pressure corrections of the read-out signal of ionization chambers have a crucial importance in order to perform high-precision absolute dose measurements. In the present work the temperature and pressure dependences of a sealed liquid isooctane filled ionization chamber (previously developed by the authors) for radiotherapy applications have been studied. We have analyzed the thermal response of the liquid ionization chamber in a {approx}20 deg. C interval around room temperature. The temperature dependence of the signal can be considered linear, with a slope that depends on the chamber collection electric field. For example, a relative signal slope of 0.27x10{sup -2}K{sup -1} for an operation electric field of 1.67x10{sup 6}Vm{sup -1} has been measured in our detector. On the other hand, ambient pressure dependence has been found negligible, as expected for liquid-filled chambers. The thermal dependence of the liquid ionization chamber signal can be parametrized within the Onsager theory on initial recombination. Considering that changes with temperature of the detector response are due to variations in the free ion yield, a parametrization of this dependence has been obtained. There is a good agreement between the experimental data and the theoretical model from the Onsager framework.

  7. Review Ionizing Radiation In The Environment

    International Nuclear Information System (INIS)

    Hassan, K.M.

    2007-01-01

    Our environment is pervaded by ionizing radiation of natural origin including terrestrial radionuclides and extra-terrestrial sources but man's activities can increase radiation levels by acting on natural sources or by producing artificial radionuclides. The energy released by radionuclides can be measured. The amount of energy generated in our bodies from the radioactive decay of within- body radionuclides is called internal dose. External dose results from gamma rays emitted by terrestrial sources such as the ground, building materials and from extraterrestrial sources. The major contributors to human exposure are radon and its daughters in the air that we breathe. Ionizing radiation can penetrate into matter and thus, causing damage by interacting with the atoms and molecules of the medium. If the medium is living tissue, damage to cells can take place. Very large doses of radiation will result in serious tissue, damage that may lead to death of the organism. Lower doses may also be harmful and do not cause the immediate damage of high doses but instead act to increase the likelihood of developing cancer. So, exposure to ionizing radiation can have health consequences, which is why we are concerned about and, to a large extent, is why this review paper was written. Exposure to ionizing radiation should be kept as minimum as practically possible. People are advised to monitor the concentrations of radon in their houses. In addition, the levels of radionuclides in drinking water should also be monitored in accordance with the guidelines used in the USA

  8. Inner shell ionization by incident nuclei

    International Nuclear Information System (INIS)

    Hansteen, J.M.

    1974-10-01

    The atomic Coulomb excitation process induced by impinging heavy charged particles such as protons, deuterons, α-particles and complex heavy ions is reviewed. Recent experimental and theoretical efforts have led toimproved understanding of the atomic Coulomb excitation as well as to discovery of new types of ionization mechanisms. The following models are mentioned: the Plane Wave Born Approximation (PWBA); theeeeeeeeeeeee modified PWBA model; the Binary Encounter Approximation (BEA); the Semi-Classical Approximation (SCA); the Perturbed-Stationary-State model (PSS). The structure of the SCA model is more thoroughly treated. Experimental results on single Coulomb ionizations of the K-, L-, and M-shells, and of the connected sub-shells by protons are compared with predictions. Most calculations are based on straight line projectile paths and non-relativistic hydrogen-like target electron wave functions. The BEA model and the SCA model seem to work reasonably well for multiple Coulomb ionizations by stripped light ions. Background effects in ion-atom collisions are commented upon. Future aspects of atomic Coulomb excitation by incident nuclei and ions are discussed. The interplay between Coulomb induced processes and united atom phenomena is especially mentioned. The simple ionization models have yielded valuable insights but it is suggested that this branch of collision physics has reached a turning point where new and more advanced and unifying models are needed. (JIW)

  9. Electron impact ionization of Ar8+

    International Nuclear Information System (INIS)

    Defrance, P.; Rachafi, S.; Jureta, J.; Meyer, F.; Chantrenne, S.

    1986-01-01

    Absolute electron impact ionization cross-sections have been measured for the Neon-like Ar 8+ in the energy range from below the threshold for the metastable state to 2500 eV. No contribution of metastable states is observed. The results are well reproduced by the Distorted Wave Born Approximation. 12 refs., 1 fig

  10. Management in the protection from ionizing radiation

    International Nuclear Information System (INIS)

    Radunovic, Miodrag; Nikolic, Krsto; Rakic, Goran

    2008-01-01

    There are numerous types and forms of endangering working and living environment, ranging from natural disasters to nuclear accidents. Challenges of the New Age determined that most of the countries reviewed its strategic decisions in the system of protection from ionizing radiation and nuclear safety and defined in a new way the threats, which could considerably imperil health of the population and national interests as well. Excessive radiation of the population became a serious and actual problem in the era of increasingly mass application of ionizing radiation, especially in medicine. The goal of this work is to reduce the risk through using knowledge and existing experiences, in particular when it comes to ionizing radiation in medicine. Optimization of the protection in radiology actually means an effort to find the compromise between quality information provided by diagnostics procedure and quality effects of therapy procedure on one side and dose of radiation received by patients on the other. Criteria for the quality management in the protection from ionizing radiation used in diagnostic radiology was given by the European Commission: European Guidelines on Quality Criteria for Diagnostic Radiographic Images, EUR, 16260. (author)

  11. Fast Atom Ionization in Strong Electromagnetic Radiation

    Science.gov (United States)

    Apostol, M.

    2018-05-01

    The Goeppert-Mayer and Kramers-Henneberger transformations are examined for bound charges placed in electromagnetic radiation in the non-relativistic approximation. The consistent inclusion of the interaction with the radiation field provides the time evolution of the wavefunction with both structural interaction (which ensures the bound state) and electromagnetic interaction. It is shown that in a short time after switching on the high-intensity radiation the bound charges are set free. In these conditions, a statistical criterion is used to estimate the rate of atom ionization. The results correspond to a sudden application of the electromagnetic interaction, in contrast with the well-known ionization probability obtained by quasi-classical tunneling through classically unavailable non-stationary states, or other equivalent methods, where the interaction is introduced adiabatically. For low-intensity radiation the charges oscillate and emit higher-order harmonics, the charge configuration is re-arranged and the process is resumed. Tunneling ionization may appear in these circumstances. Extension of the approach to other applications involving radiation-induced charge emission from bound states is discussed, like ionization of molecules, atomic clusters or proton emission from atomic nuclei. Also, results for a static electric field are included.

  12. An analytical excitation for an ionizing plasma

    NARCIS (Netherlands)

    Mullen, van der J.J.A.M.; Sijde, van der B.; Schram, D.C.

    1983-01-01

    From an analytical model for the population of high-lying excited levels in ionizing plasmas it appears that the distribution is a superposition of the equilibrium (Saha) value and an overpopulation. This overpopulation takes the form of a Maxwell distribution for free electrons. Experiments for He

  13. Penetration of electronic beams in ionizing media

    International Nuclear Information System (INIS)

    Martiarena, M.L.; Zanete, D.H.; Garibotti, C.R.

    1988-01-01

    It is studied the penetration of an electron beam in an ionizable medium by means of a generalized kinetic equation. This equation is related to elastic collisions, processes of creation and destruction of particles. By integrating numerically the transport equation, it can be evaluated the relative effects of all the processes involved in the evolution of the system. (A.C.A.S.) [pt

  14. Notes on photon assisted field ionization

    International Nuclear Information System (INIS)

    Niu, B.H.C.; Bryant, P.J.

    1979-01-01

    A response to comments by Viswanathan et al (2) on a previous publication(1) by the authors is given. It is contended that the original hypothesis of photon assisted field ionization at metal surfaces correctly explains the results reported in Ref. 1

  15. Propagating discontinuities in ionized porous media

    NARCIS (Netherlands)

    Kraaijeveld, F.

    2009-01-01

    Ionized porous media swell or shrink under changing osmotic conditions. Examples of such materials are shales, clays, hydrogels and tissues. The materials are represented as a multi-phase material consisting of a solid part and a fluid part with fixed charges embedded in the solid matrix and counter

  16. Doses and biological effect of ionizing radiation

    International Nuclear Information System (INIS)

    Hrynkiewicz, A.

    1993-01-01

    The aim of the monograph is to review practical aspects of dosimetry. The work describes basic units which are used in dosimetry and natural as well as industrial sources of ionizing radiation. Information given in the monograph help in assessment of the radiation risk. 8 refs, 15 tabs

  17. Ionization model for nickel-like gold

    International Nuclear Information System (INIS)

    Busquet, M.; Bruneau, J.

    1986-04-01

    Before we build an extensive population model for gold ionized 49 to 52 times, we have studied with a more simple model the effect of accounting for cascades (or dielectronic recombination) and Δn = 0 transitions. These transitions allow some understanding of typical feature of experimental gold spectra

  18. Metrology of ionizing radiations and environmental measurements

    International Nuclear Information System (INIS)

    Nourreddine, Abdel-Mjid

    2008-01-01

    The subject of radiation protection covers all measurements taken by the authorities to ensure protection of the population and its environment against the harmful effects of ionizing radiation. Dosimetry occupies an important place in this field, because it makes it possible to consider and to quantify the risk of using radiations in accordance with the prescribed limits. In this course, we will review the fundamental concepts used in the metrology and dosimetry of ionizing radiations. After classification of ionizing radiations according to their interactions with biological matter, we will present the various quantities and units brought into play and in particular the new operational quantities that are good estimators raising protection standards. They are directly connected to the annual limits of effective dose and of equivalent dose defined in the French regulation relating to the protection of the population and of workers against ionizing radiations. The average natural exposure of the population in France varies between 2 to 2.5 mSv per year, depending on geographic location. It comes principally from three sources: cosmic radiation, radioactive elements contained in the ground and radioactive elements that we absorb when breathing or eating. Radon, which is a naturally occurring radioactive gas, is a public health risk and represents 30% of the exposure. Finally, we will give some applications of dosimetry and environmental measurements developed recently at RaMsEs/IPHC laboratory of Strasbourg. (author)

  19. Chemical protection against ionizing radiation. Final report

    International Nuclear Information System (INIS)

    Livesey, J.C.; Reed, D.J.; Adamson, L.F.

    1984-08-01

    The scientific literature on radiation-protective drugs is reviewed. Emphasis is placed on the mechanisms involved in determining the sensitivity of biological material to ionizing radiation and mechanisms of chemical radioprotection. In Section I, the types of radiation are described and the effects of ionizing radiation on biological systems are reviewed. The effects of ionizing radiation are briefly contrasted with the effects of non-ionizing radiation. Section II reviews the contributions of various natural factors which influence the inherent radiosensitivity of biological systems. Inlcuded in the list of these factors are water, oxygen, thiols, vitamins and antioxidants. Brief attention is given to the model describing competition between oxygen and natural radioprotective substances (principally, thiols) in determining the net cellular radiosensitivity. Several theories of the mechanism(s) of action of radioprotective drugs are described in Section III. These mechanisms include the production of hypoxia, detoxication of radiochemical reactive species, stabilization of the radiobiological target and the enhancement of damage repair processes. Section IV describes the current strategies for the treatment of radiation injury. Likely areas in which fruitful research might be performed are described in Section V. 495 references

  20. Several versions of forward gas ionization calorimeter

    International Nuclear Information System (INIS)

    Babintsev, V.V.; Kholodenko, A.G.; Rodnov, Yu.V.

    1994-01-01

    The properties of several versions of a gas ionization calorimeter are analyzed by means of the simulation with the GEANT code. The jet energy and coordinate resolutions are evaluated. Some versions of the forward calorimeter meet the ATLAS requirements. 13 refs., 15 figs., 7 tabs

  1. Roles of ionizing radiation in cell transformation

    International Nuclear Information System (INIS)

    Tobias, C.A.; Albright, N.W.; Yang, T.C.

    1983-07-01

    Earlier the authors described a repair misrepair model (RMR-I) which is applicable for radiations of low LET, e.g., x rays and gamma rays. RMR-II was described later. Here is introduced a mathematical modification of the RMR model, RMR-III, which is intended to describe lethal effects caused by heavily ionizing tracks. 31 references, 4 figures

  2. Long-term effects of ionizing radiation

    International Nuclear Information System (INIS)

    Kaul, Alexander; Burkart, Werner; Grosche, Bernd; Jung, Thomas; Martignoni, Klaus; Stephan, Guenther

    1997-01-01

    This paper approaches the long-term effects of ionizing radiation considering the common thought that killing of cells is the basis for deterministic effects and that the subtle changes in genetic information are important in the development of radiation-induced cancer, or genetic effects if these changes are induced in germ cells

  3. Chemical protection against ionizing radiation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Livesey, J.C.; Reed, D.J.; Adamson, L.F.

    1984-08-01

    The scientific literature on radiation-protective drugs is reviewed. Emphasis is placed on the mechanisms involved in determining the sensitivity of biological material to ionizing radiation and mechanisms of chemical radioprotection. In Section I, the types of radiation are described and the effects of ionizing radiation on biological systems are reviewed. The effects of ionizing radiation are briefly contrasted with the effects of non-ionizing radiation. Section II reviews the contributions of various natural factors which influence the inherent radiosensitivity of biological systems. Inlcuded in the list of these factors are water, oxygen, thiols, vitamins and antioxidants. Brief attention is given to the model describing competition between oxygen and natural radioprotective substances (principally, thiols) in determining the net cellular radiosensitivity. Several theories of the mechanism(s) of action of radioprotective drugs are described in Section III. These mechanisms include the production of hypoxia, detoxication of radiochemical reactive species, stabilization of the radiobiological target and the enhancement of damage repair processes. Section IV describes the current strategies for the treatment of radiation injury. Likely areas in which fruitful research might be performed are described in Section V. 495 references.

  4. Alanine-polymer dosemeter of ionizing radiation

    International Nuclear Information System (INIS)

    Tomasinski, Z.; Mirkowski, K.; Panta, P.; Stachowicz, W.

    1994-01-01

    The method of chemical preparation of alanine-copolymer of ethylene and vinyl acetate has been worked out. The material has been in a form of rods. The content of alanine has not exceeded 30%. The ESR signal of alanine radicals has been detected after exposition to ionizing radiation. The dose-response relationship has been presented

  5. The industrial applications of ionizing radiations

    International Nuclear Information System (INIS)

    1992-10-01

    This report presents all industrial applications of ionizing radiations in France, for food preservation, radiosterilization of drugs, medical materials and cosmetic products, for radiation chemistry of polymers. This report also describes the industrial plants of irradiation (electron, cobalt 60). Finally, it explains the legal and safety aspects

  6. Historical survey of resonance ionization spectroscopy

    International Nuclear Information System (INIS)

    Hurst, G.S.

    1984-04-01

    We have recently celebrated the 10th birthday of Resonance Ionization Spectroscopy (RIS), and this seems an appropriate time to review the history of its development. Basically, RIS is a photophysics process in which tunable light sources are used to remove a valence electron from an atom of selected atomic number, Z. If appropriate lasers are used as the light source, one electron can be removed from each atom of the selected Z in the laser pulse. This implies that RIS can be a very efficient, as well as selective, ionization process. In what we normally call RIS, laser schemes are employed which preserve both of these features. In contrast, multiphoton ionization (MPI) is more general, although not necessarily Z selective or very efficient because resonances are often not used. Early research completed in the USSR and described as selective two-step photoionization, employed resonances to ionize the rubidium atom and served to guide work on laser isotope separation. 29 references, 8 figures

  7. Preservation of almonds by ionizing radiation

    International Nuclear Information System (INIS)

    Trabelsi, M.

    1997-01-01

    During two months, a series of experiments was carried out to highlight the effects of preservation by ionizing radiation of a variety of Tunisian almonds. This technique was proved correct for doses less than 1 KGy. Nevertheless, this technique may be harmful to proteins.(author)

  8. Composite scintillators for detection of ionizing radiation

    Science.gov (United States)

    Dai, Sheng [Knoxville, TN; Stephan, Andrew Curtis [Knoxville, TN; Brown, Suree S [Knoxville, TN; Wallace, Steven A [Knoxville, TN; Rondinone, Adam J [Knoxville, TN

    2010-12-28

    Applicant's present invention is a composite scintillator having enhanced transparency for detecting ionizing radiation comprising a material having optical transparency wherein said material comprises nano-sized objects having a size in at least one dimension that is less than the wavelength of light emitted by the composite scintillator wherein the composite scintillator is designed to have selected properties suitable for a particular application.

  9. Interaction of ionizing radiation with matter

    International Nuclear Information System (INIS)

    Calisto, Washington

    1994-01-01

    Definition of ionizing radiation,interaction of electrons with matter,physical model of collision,elastic and inelastic collisions,range of electron in matter,interaction of photon with matter.Photoelectric effect , Compton effect,pair production,consideration of interaction of various radiations with soft tissue

  10. Ionization Energy: Implications of Preservice Teachers' Conceptions

    Science.gov (United States)

    Tan, Kim Chwee Daniel; Taber, Keith S.

    2009-01-01

    The results from a study to explore pre-service teachers' understanding of ionization energy, a topic that features in A-level (grade 11 and 12) chemistry courses. in Singapore , is described. A previous study using a two-tier multiple choice diagnostic test has shown that Singapore A-level students have considerable difficulty understanding the…

  11. Theory of multiphoton ionization of atoms

    International Nuclear Information System (INIS)

    Szoeke, A.

    1986-03-01

    A non-perturbative approach to the theory of multiphoton ionization is reviewed. Adiabatic Floquet theory is its first approximation. It explains qualitatively the energy and angular distribution of photoelectrons. In many-electron atoms it predicts collective and inner shell excitation. 14 refs

  12. Dynamics of tunneling ionization using Bohmian mechanics

    Science.gov (United States)

    Douguet, Nicolas; Bartschat, Klaus

    2018-01-01

    Recent attoclock experiments and theoretical studies regarding the strong-field ionization of atoms by few-cycle infrared pulses revealed features that have attracted much attention. Here we investigate tunneling ionization and the dynamics of the electron probability using Bohmian mechanics. We consider a one-dimensional problem to illustrate the underlying mechanisms of the ionization process. It is revealed that in the major part of the below-the-barrier ionization regime, in an intense and short infrared pulse, the electron does not tunnel through the entire barrier, but rather starts already from the classically forbidden region. Moreover, we highlight the correspondence between the probability of locating the electron at a particular initial position and its asymptotic momentum. Bohmian mechanics also provides a natural definition of mean tunneling time and exit position, taking account of the time dependence of the barrier. Finally, we find that the electron can exit the barrier with significant kinetic energy, thereby corroborating the results of a recent study [N. Camus et al., Phys. Rev. Lett. 119, 023201 (2017), 10.1103/PhysRevLett.119.023201].

  13. Ionizing radiation in the education of medicine

    International Nuclear Information System (INIS)

    Ivanova, N.

    2016-01-01

    Physics is a fundamental science that finds its applications in all areas of our lives. Its application in modern medicine is undeniable. In today’s medical practice special attention is dedicated to the use of ionizing radiation. The wide range of modern science and technology offers enormous possibilities for creation and implementation of new equipment using adequate doses of ionizing radiation. For accurate medical diagnostics and effective treatment of patients, this type of equipment must provide the necessary information to the physicians. On the other hand, the physicians should possess enough knowledge in the relative field of medicine. This paper contains information about the knowledge communicated to the students of the graduate program Medical Physics and Biophysics in the discipline Medicine in the first year of graduate study at the Medical University “Prof. Dr. Paraskev Stoyanov” of Varna. Firstly, we discuss the topics in the lectures of these two disciplines, concerning knowledge about ionizing radiation. Secondly, the respective laboratory exercises are described that illustrate the lectures in the graduate programs Medical Physics and Biophysics. Keywords: ionizing radiation, education, medicine, medical physics, biophysics

  14. Circuit for current measures from ionization chambers

    International Nuclear Information System (INIS)

    Mello, F.L.V. de; Oliveira, A.H. de; Rezende, R.S.

    1992-01-01

    The design and the specifications of an ammeters of low cost for small current, IOE-14 Ampere, from ionization chambers or others transducers used in nuclear instrumentation are described. Special attention is given to the integrated electronic components, available in the brazilian market. (C.G.C.)

  15. Ionization of amphiphilic acidic block copolymers.

    Science.gov (United States)

    Colombani, Olivier; Lejeune, Elise; Charbonneau, Céline; Chassenieux, Christophe; Nicolai, Taco

    2012-06-28

    The ionization behavior of an amphiphilic diblock copolymer poly(n-butyl acrylate(50%)-stat-acrylic acid(50%))(100)-block-poly(acrylic acid)(100) (P(nBA(50%)-stat-AA(50%))(100)-b-PAA(100), DH50) and of its equivalent triblock copolymer P(nBA(50%)-stat-AA(50%))(100)-b-PAA(200)-b-P(nBA(50%)-stat-AA(50%))(100) (TH50) were studied by potentiometric titration either in pure water or in 0.5 M NaCl. These polymers consist of a hydrophilic acidic block (PAA) connected to a hydrophobic block, P(nBA(50%)-stat-AA(50%))(100), whose hydrophobic character has been mitigated by copolymerization with hydrophilic units. We show that all AA units, even those in the hydrophobic block could be ionized. However, the AA units within the hydrophobic block were less acidic than those in the hydrophilic block, resulting in the preferential ionization of the latter block. The preferential ionization of PAA over that of P(nBA(50%)-stat-AA(50%))(100) was stronger at higher ionic strength. Remarkably, the covalent bonds between the PAA and P(nBA(50%)-stat-AA(50%))(100) blocks in the diblock or the triblock did not affect the ionization of each block, although the self-association of the block copolymers into spherical aggregates modified the environment of the PAA blocks compared to when PAA was molecularly dispersed.

  16. Electron Impact Excitation-Ionization of Molecules

    Science.gov (United States)

    Ali, Esam Abobakr A.

    In the last few decades, the study of atomic collisions by electron-impact has made significant advances. The most difficult case to study is electron impact ionization of molecules for which many approximations have to be made and the validity of these approximations can only be checked by comparing with experiment. In this thesis, I have examined the Molecular three-body distorted wave (M3DW) or Molecular four-body distorted wave (M4DW) approximations for electron-impact ionization. These models use a fully quantum mechanical approach where all particles are treated quantum mechanically and the post collision interaction (PCI) is treated to all orders of perturbation. These electron impact ionization collisions play central roles in the physics and chemistry of upper atmosphere, biofuel, the operation of discharges and lasers, radiation induced damage in biological material like damage to DNA by secondary electrons, and plasma etching processes. For the M3DW model, I will present results for electron impact single ionization of small molecules such as Water, Ethane, and Carbon Dioxide and the much larger molecules Tetrahydrofuran, phenol, furfural, 1-4 Benzoquinone. I will also present results for the four-body problem in which there are two target electrons involved in the collision. M4DW results will be presented for dissociative excitation-ionization of orientated D2. I will show that M4DW calculations using a variational wave function for the ground state that included s- and p- orbital states give better agreement to the experimental measurements than a ground state approximated as a product of two 1s-type Dyson orbitals.

  17. Detoxification of snake venom using ionizing radiation

    International Nuclear Information System (INIS)

    Rogero, J.R.; Nascimento, N.

    1995-01-01

    It is generally recognized that energy absorbed by ionizing radiation (gamma rays) can inactivate biological material in tow ways. A direct effects occurs when the primary event, i.e., ionization, is produced in the molecule itself. This is the case when a compound is irradiated in dry state. When a compound is irradiated in a solution, the indirect effect joins the direct. Since water is the most abundant constituent of biological material, it is important to consider the species produced by excitation and ionization of water itself, and the reaction of these species with the target molecules of biological importance. This indirect effect results from the reactions among the studied molecules and the products of radiation interaction with water or other solvents. Highly reactive compounds, the so-called free radicals, which are formed many reactions among themselves, with the dissolved gas, and with other molecules in the solution. With water, the excitation is less important than ionization which is followed within picosecond by the formation of free hydroxyl radicals and hydrated electrons. Alexander and Hamilton showed that irradiation of proteins has revealed damage to aminoacid side chains, production of new groups, splitting of peptide bonds and formation of intramolecular and intermolecular cross-links. With these results it would be possible to use ionizing radiation to change those proteins molecules in order to improve some of their properties according to the necessity. On the other hand, it is recognized that venoms in general are poorly immunogenic, yet fairly toxic. This cause problems because serotherapy is the treatment of choice in snakebite envenomations, and horse antivenom availability is dependent upon. (author)

  18. First successful ionization of Lr (Z = 103) by a surface-ionization technique

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Tetsuya K., E-mail: sato.tetsuya@jaea.go.jp; Sato, Nozomi; Asai, Masato; Tsukada, Kazuaki; Toyoshima, Atsushi; Ooe, Kazuhiro; Miyashita, Sunao; Schädel, Matthias [Advanced Science Research Center, Japan Atomic Energy Agency (JAEA), 2-4 Shirakata-shirane, Tokai-mura, Ibaraki 319-1195 (Japan); Kaneya, Yusuke; Nagame, Yuichiro [Advanced Science Research Center, Japan Atomic Energy Agency (JAEA), 2-4 Shirakata-shirane, Tokai-mura, Ibaraki 319-1195 (Japan); Graduate School of Science and Engineering, Ibaraki University, 2-1-1, Bunkyo, Mito, Ibaraki 310-8512 (Japan); Osa, Akihiko [Department of Research Reactor and Tandem Accelerator, Japan Atomic Energy Agency (JAEA), 2-4 Shirakata shirane, Tokai-mura, Ibaraki 319-1195 (Japan); Ichikawa, Shin-ichi [Advanced Science Research Center, Japan Atomic Energy Agency (JAEA), 2-4 Shirakata-shirane, Tokai-mura, Ibaraki 319-1195 (Japan); Nishina Center for Accelerator-Based Science, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Stora, Thierry [ISOLDE, CERN, CH-1211 Geneva 23 (Switzerland); Kratz, Jens Volker [Institut für Kernchemie, Universität Mainz, D-55099 Mainz (Germany)

    2013-02-15

    We have developed a surface ionization ion-source as part of the JAEA-ISOL (Isotope Separator On-Line) setup, which is coupled to a He/CdI{sub 2} gas-jet transport system to determine the first ionization potential of the heaviest actinide lawrencium (Lr, Z = 103). The new ion-source is an improved version of the previous source that provided good ionization efficiencies for lanthanides. An additional filament was newly installed to give better control over its operation. We report, here, on the development of the new gas-jet coupled surface ion-source and on the first successful ionization and mass separation of 27-s {sup 256}Lr produced in the {sup 249}Cf + {sup 11}B reaction.

  19. Absorbed dose measurement by using tissue equivalent ionization chamber (pair ionization chamber) in the Yayoi reactor

    International Nuclear Information System (INIS)

    Sasuga, N.; Okamura, K.; Terakado, T.; Mabuchi, Y.; Nakagawa, T.; Sukegawa, Toshio; Aizawa, C.; Saito, I.; Oka, Yoshiaki

    1998-01-01

    Each dose rate of neutron and gamma ray in the thermal column of the Yayoi reactor, in which an epithermal neutron field will be used for the boron neutron capture therapy, was measured by using a tissue equivalent ionization chamber and a graphite chamber. The tissue equivalent ionization chamber has some response to both neutron and gamma ray, but the graphite chamber has a few response to the neutron, so called pair ionization chamber method. The epithermal neutron fluxes of the thermal column were calculated by ANISN (one dimensional neutron-gamma transport code). A measured value for gamma dose rate by the pair ionization chamber agrees relevantly with a calculated result. For neutron dose rate, however, the measured value was too much small in comparison with the calculated result. The discrepancy between the measured value and the calculated result for neutron dose rate is discussed in detail in the report. (M. Suetake)

  20. Ionization of xenon by electrons: Partial cross sections for single, double, and triple ionization

    International Nuclear Information System (INIS)

    Mathur, D.; Badrinathan, C.

    1987-01-01

    High-sensitivity measurements of relative partial cross sections for single, double, and triple ionization of Xe by electron impact have been carried out in the energy region from threshold to 100 eV using a crossed-beam apparatus incorporating a quadrupole mass spectrometer. The weighted sum of the relative partial cross sections at 50 eV are normalized to the total ionization cross section of Rapp and Englander-Golden to yield absolute cross-section functions. Shapes of the partial cross sections for single and double ionization are difficult to account for within a single-particle picture. Comparison of the Xe + data with 4d partial photoionization cross-section measurements indicates the important role played by many-body effects in describing electron-impact ionization of high-Z atoms

  1. Estimation of the contribution of ionization and excitation to the lethal effect of ionizing radiation

    International Nuclear Information System (INIS)

    Petin, V.G.; Komarov, V.P.

    1982-01-01

    A simple theoretical model is proposed for estimating the differential contribution of ionization and excitation to the lethal effect of ionizing radiation. Numerical results were obtained on the basis of published experimental data on the ability of bacterial cells Escherichia coli to undergo photoreactivation of radiation-induced damage. It was shown that inactivation by excitation may be highly significant for UV-hypersensitive cells capable of photoreactivation; inactivation by excitation increased with the energy of ionizing radiation and the volume of irradiated suspensions. The data are in qualitative agreement with the assumption of a possible contribution of the UV-component of Cerenkov radiation to the formation of excitations responsible for the lethal effect and the phenomenon of photoreactivation after ionizing radiation. Some predictions from the model are discussed. (orig.)

  2. Measurement of the first ionization potential of astatine by laser ionization spectroscopy

    Science.gov (United States)

    Rothe, S.; Andreyev, A. N.; Antalic, S.; Borschevsky, A.; Capponi, L.; Cocolios, T. E.; De Witte, H.; Eliav, E.; Fedorov, D. V.; Fedosseev, V. N.; Fink, D. A.; Fritzsche, S.; Ghys, L.; Huyse, M.; Imai, N.; Kaldor, U.; Kudryavtsev, Yuri; Köster, U.; Lane, J. F. W.; Lassen, J.; Liberati, V.; Lynch, K. M.; Marsh, B. A.; Nishio, K.; Pauwels, D.; Pershina, V.; Popescu, L.; Procter, T. J.; Radulov, D.; Raeder, S.; Rajabali, M. M.; Rapisarda, E.; Rossel, R. E.; Sandhu, K.; Seliverstov, M. D.; Sjödin, A. M.; Van den Bergh, P.; Van Duppen, P.; Venhart, M.; Wakabayashi, Y.; Wendt, K. D. A.

    2013-01-01

    The radioactive element astatine exists only in trace amounts in nature. Its properties can therefore only be explored by study of the minute quantities of artificially produced isotopes or by performing theoretical calculations. One of the most important properties influencing the chemical behaviour is the energy required to remove one electron from the valence shell, referred to as the ionization potential. Here we use laser spectroscopy to probe the optical spectrum of astatine near the ionization threshold. The observed series of Rydberg states enabled the first determination of the ionization potential of the astatine atom, 9.31751(8) eV. New ab initio calculations are performed to support the experimental result. The measured value serves as a benchmark for quantum chemistry calculations of the properties of astatine as well as for the theoretical prediction of the ionization potential of superheavy element 117, the heaviest homologue of astatine. PMID:23673620

  3. Application of ionizing radiation to preservation of mushrooms

    International Nuclear Information System (INIS)

    Smierzchalska, K.; Gubrynowicz, E.

    1979-01-01

    The influence of ionizing radiation on prolongation of preservation time and quality of mushrooms is discussed. Some numerical data are cited. The influence of ionizing radiation on growth rate and physiological processes is also presented. (A.S.)

  4. Fully differential cross sections for heavy particle impact ionization

    Energy Technology Data Exchange (ETDEWEB)

    McGovern, M; Walters, H R J [Department of Applied Mathematics and Theoretical Physics, Queen' s University, Belfast BT7 1NN (United Kingdom); Assafrao, D; Mohallem, J R [Laboratorio de Atomos e Moleculas Especiais, Departamento de Fisica, ICEx, Universidade Federal de Minas Gerais, P.O Box 702, 30123-970 Belo Horizonte, MG (Brazil); Whelan, Colm T, E-mail: mmcgovern06@qub.ac.u [Department of Physics, Old Dominion University, Norfolk, VA 23529-0116 (United States)

    2009-11-15

    We describe a procedure for extracting fully differential ionization cross sections from an impact parameter coupled pseudostate treatment of the collision. Some examples from antiproton impact ionization of atomic Hydrogen are given.

  5. To the calculation of energy resolution of ionization calorimeter

    International Nuclear Information System (INIS)

    Uchajkin, V.V.; Lagutin, A.A.

    1976-01-01

    The question of energy resolution of the ionization calorimeter is considered analytically. A method is discussed for calculating the probability characteristics (mean value and dispersion) of energy losses of an electron-photon shower by ionization in the calorimeter volume

  6. Single and double ionization of gallium by electron impact

    Indian Academy of Sciences (India)

    Electron impact single and double ionization cross sections of gallium have been calcu- ... The experimental data on single ionization have been compared with the empirical and ..... and multiplication sign curve (¢¢¢) represent present.

  7. Ionization of highly excited atoms by atomic particle impact

    International Nuclear Information System (INIS)

    Smirnov, B.M.

    1976-01-01

    The ionization of a highly excited atom by a collision with an atom or molecule is considered. The theory of these processes is presented and compared with experimental data. Cross sections and ionization potential are discussed. 23 refs

  8. Ionizing radiation in earth's atmosphere and in space near earth.

    Science.gov (United States)

    2011-05-01

    The Civil Aerospace Medical Institute of the FAA is charged with identifying health hazards in air travel and in : commercial human space travel. This report addresses one of these hazards ionizing radiation. : Ionizing radiation is a subatomic p...

  9. On possible structures of transverse ionizing shock waves

    International Nuclear Information System (INIS)

    Liberman, M.A.; Velikovich, A.L.

    1978-01-01

    The possible structures of ionizing shock waves propagating in gases across the magnetic field are investigated taking account of both ionization kinetics and the non-isothermality of the plasma which is formed within the shock front. It is shown that a definite factor in shaping the structure of the transverse ionizing shock wave is photo-ionization of the neutral gas across the front. The paper includes a study of the evolution of the transverse ionizing shock front with regard to photo-ionization, disclosing that a stable stationary shock structure emerges only in boundary conditions which are close to magnetohydrodynamic ones, i.e. upsilon 1 H 1 = upsilon 2 H 2 . In the case of strong transverse ionizing shock waves, when the flux of ionizing radiation across the front is great, the shock structure is obviously magnetohydrodynamic. (author)

  10. The theory of ionizing shock waves in a magnetic field

    International Nuclear Information System (INIS)

    Liberman, M.A.; Velikovich, A.L.

    1981-01-01

    The general theory of ionizing shock waves in a magnetic field is constructed. The theory takes into account precursor ionization of a neutral gas ahead of the shock wave front, caused by photo-ionization, as well as by the impact ionization with electrons accelerated by a transverse electric field induced by the shock front in the incident flow of a neutral gas. The concept of shock wave ionization stability, being basic in the theory of ionizing shock waves in a magnetic field, is introduced. The ionizing shock wave structures are shown to transform from the GD regime at a low shock velocity to the MHD regime at an enhanced intensity of the shock wave. The abruptness of such a transition is determined by precursor photo-ionization. (author)

  11. Ionization dual-zone static detector having single radioactive source

    International Nuclear Information System (INIS)

    Ried, L. Jr.; Wade, A.L.

    1977-01-01

    This ionization detector or combustion product detector includes a single radioactive source located in an ionization chamber, and the ionization chamber includes portions comprising a reference zone and a signal zone. Electrical circuitry connected to the reference and signal zones provides an output signal directly related to changes in voltages across the signal zone in relation to the amount of particulates of combustion present in the ionization chamber

  12. Apparatus for reading and recharging condenser ionization chambers

    International Nuclear Information System (INIS)

    McCall, R.C.

    1977-01-01

    A metering circuit for a condenser ionization chamber is disclosed for simultaneously recharging the ionization chamber and reading out the amount of charge required to recharge the chamber. During the recharging process, the amount of charge necessary to recharge the ionization chamber capacitor is placed on an integrating capacitor in the metering apparatus. The resultant voltage across the integrating capacitor is a measure of the radiation to which the ionization chamber was exposed. 9 claims, 1 figure

  13. Ionizing energy in food processing and pest control. 1. Wholesomeness of food treated with ionizing energy

    International Nuclear Information System (INIS)

    Wierbicki, Eugen

    1986-01-01

    Congressional concerns about the use of ionizing energy for food preservation and to control pests in food products for export and domestic use promoted the preparation of this report by a special task force of the Council for Agricultural Science and Technology (CAST). An overview surveys research conducted on the toxicological safety, nutritional quality, and microbiological safety of foods treated with ionizing energy. Background information is provided on various types of electromagnetic radiation, effects of ionizing energy level and dose, sources of natural background radiation and induced radioactivity, and the nature and safety of various radiolytic products. Objectives, methodologies, and problems associated with feeding studies of toxicological safety are outlined; results of scientific studies, U.S. government wholesomeness studies, and international feeding studies are summarized. Studies on the nutritional value of food products processed using ionized energy have examined the effects of ionizing energy on 1) composite diets, 2) carbohydrates, 3) fats, 4) proteins and amino acids, 5) vitamins (potatoes, onions, fruits, meat, seafood, cereals, vegetables, dairy products, oils), 6) antivitamins, and 7) minerals. The report concludes that currently available scientific evidence indicates that foods exposed to ionizing energy under the conditions proposed for commercial application are 1) wholesome (safe to eat) and 2) comparable in nutritional adequacy to fresh or conventionally processed foods

  14. State and trends of ionization gas analysis. 1

    International Nuclear Information System (INIS)

    Leonhardt, J.W.; Grosse, H.J.; Popp, P.

    1980-01-01

    The ionization gas analysis makes use of the fact that the ionization-induced conductivity of gases and gas mixtures changes with the composition of such mixtures. A general description is given of ionization detectors based on this principle and theory, properties, and main fields of application of electron capture detectors are discussed

  15. Measurement of indoor background ionizing radiation in some ...

    African Journals Online (AJOL)

    Certain types of building materials are known to be radioactive. Exposure to indoor ionizing radiation like exposure to any other type of ionizing radiation results in critical health challenges. Measurement of the background ionizing radiation profile within the Chemistry Research Laboratory and Physics Laboratory III all of ...

  16. Six categories of ionizing radiation quantities practical in various fields

    International Nuclear Information System (INIS)

    Zheng Junzheng; Zhuo Weihai

    2011-01-01

    This paper is the part of review on the evolvement of the systems for ionizing radiation quantities and units. In the paper, for better understanding and correct use of the relevant quantities of ionizing radiation, the major ionizing radiation quantities in various fields are divided into six categories. (authors)

  17. Method and apparatus to monitor a beam of ionizing radiation

    Science.gov (United States)

    Blackburn, Brandon W.; Chichester, David L.; Watson, Scott M.; Johnson, James T.; Kinlaw, Mathew T.

    2015-06-02

    Methods and apparatus to capture images of fluorescence generated by ionizing radiation and determine a position of a beam of ionizing radiation generating the fluorescence from the captured images. In one embodiment, the fluorescence is the result of ionization and recombination of nitrogen in air.

  18. Rational Design of Therapeutic and Diagnostic Against Botulinum Neurotoxin

    Science.gov (United States)

    2006-12-01

    induced fluorescence Da, kDa Dalton, Kilodalton DMPS 2, 3-dimercaptopropanesulfonate DMSO Dimethylsulfoxide Dnp 2, 4-dinitrophenol DRDC Defence...high performance liquid chromatography electrospray ionization mass spectrometry (HPLC-ESI-MS) experiment. H1R3 was dissolved in 10% DMSO / 0.1...separation of peptides. A linear solvent gradient was used in the HPLC separation at an initial condition of 5% acetonitrile in 0.1% TFA/water, up to

  19. Health consequences of ionizing radiation exposure

    International Nuclear Information System (INIS)

    Dalci, D.; Dorter, G.; Guclu, I.

    2004-01-01

    The increasing use of ionizing radiations all over the world induces an ever increasing interest of the professionals as well as of the whole society in health protection and the risk due to these practices. Shortly after its discovery, it was recognized that ionizing radiation can have adverse health effects and knowledge of its detrimental effects has accumulated. The fact that ionizing radiation produces biological damage has been known for many years. The biological effects of ionizing radiation for radiation protection considerations are grouped into two categories: The deterministic and the stochastic ones. Deterministic radiation effects can be clinically diagnosed in the exposed individual and occur when above a certain 'threshold' an appropriately high dose is absorbed in the tissues and organs to cause the death of a large number of cells and consequently to impair tissue or organ functions early after exposure. A clinically observable biological effect (Acute Radiation Syndromes, ARS) that occurs days to months after an acute radiation dose. ARS is a complex of acute injury manifestations that occur after a sufficiently large portion of a person's body is exposed to a high dose of ionizing radiation. Such irradiation initially injures all organs to some extent, but the timing and extent of the injury manifestations depend upon the type, rate, and dose of radiation received. Stochastic radiation effects are the chronic effects of radiation result from relatively low exposure levels delivered over long periods of time. These are sort of effects that might result from occupational exposure, or to the background exposure levels (includes radioactive pollution). Such late effects might be the development of malignant (cancerous) disease and of the hereditary consequences. These effects may be observed many years after the radiation exposure. There is a latent period between the initial radiation exposure and the development of the biological effect. In this

  20. The study of the effects of ionizing and non-ionizing radiations on birth weight of newborns to exposed mothers

    OpenAIRE

    Mortazavi, S. M. J.; Shirazi, K. R.; Mortazavi, G.

    2013-01-01

    Objectives: Life evolved in an environment filled with a wide variety of ionizing and non-ionizing radiation. It was previously reported that medical exposures to pregnant women increases the risk of low birth weight. This study intends to investigate the relationship between exposure to ionizing and non-ionizing radiation and the risk of low birth weight. Materials and Methods: One thousand two hundred mothers with their first-term labor (vaginal or cesarean) whose newborns? history had been...