WorldWideScience

Sample records for n-tof facility mesures

  1. Detailed analysis of the KAERI nTOF facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Woon; Lee, Young Ouk [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-06-15

    A project for building a neutron time-of-flight (nTOF) facility is progressing. We expect that the construction will start in early 2016. Before that, a detailed simulation based on the current architectural drawings was performed to optimize the performance of our facility. Currently, several parts had been modified or changed from the original design to reflect requirements such as the layout of the electron beam line, shape of the vacuum chamber producing a neutron beam, and the underground layout of the nTOF facility. Detailed analysis for these modifications has been done with MCNP simulation. An overview of our photo-neutron source and KAERI nTOF facility were introduced. The numerical simulations for heat deposition, source term, and radiation shielding of KAERI nTOF facility were performed and the results are discussed. We are expecting that the construction of the KAERI nTOF facility will start in early 2016, and these results will be used as basic data.

  2. n_TOF facility past and future

    CERN Document Server

    Vlachoudis, V

    2010-01-01

    The neutron Time of Flight (n_TOF) facility at CERN is a source of high flux of neutrons obtained by the spallation process of 20 GeV/c protons onto a solid lead target and the remarkable beam intensity of the Proton Synchrotron (PS). From November 2008 the n_TOF facility resumed operation after a halt of 4 years due to radio-protection issues. It features a new lead spallation target with a more robust design, more efficient cooling, separate moderator circuit, target area ventilation and most important without any loss of the unique neutron performances of the previous target. Moreover the separate moderator circuit will permit in the future the use of borated or heavy water instead of normal water to reduce the 2.2 MeV gamma background for the neutron capture measurements. The facility has been commissioned in Nov 2008, with performances similar of the previous target and predicted by Monte Carlo simulations. The facility will resume operation for physics from May 2009 with 4 experimental proposals already...

  3. Neutron cross-section measurements at the nTOF facility at CERN

    CERN Document Server

    Colonna, N

    2004-01-01

    A neutron Time-of-Flight facility (n_TOF) has recently become operative at CERN. The innovative features of the neutron beam, in particular the high instantaneous flux, the wide energy range, the high resolution and the low background, make this facility unique for measurements of neutron-induced reactions relevant to the field of emerging nuclear technologies, as well as to Nuclear Astrophysics and fundamental Nuclear Physics. The n_TOF facility is here described, together with the main features of the experimental apparata used for cross-section measurements. The results of the first measurement campaign, which have confirmed the innovative aspects of the facility, are presented. The measurement plan of the n_TOF collaboration, in particular with regard to implications to ADS, is briefly discussed.

  4. Dissemination of data measured at the CERN n_TOF facility

    Science.gov (United States)

    Dupont, E.; Otuka, N.; Cabellos, O.; Aberle, O.; Aerts, G.; Altstadt, S.; Alvarez, H.; Alvarez-Velarde, F.; Andriamonje, S.; Andrzejewski, J.; Audouin, L.; Bacak, M.; Badurek, G.; Balibrea, J.; Barbagallo, M.; Barros, S.; Baumann, P.; Bécares, V.; Bečvář, F.; Beinrucker, C.; Belloni, F.; Berthier, B.; Berthoumieux, E.; Billowes, J.; Boccone, V.; Bosnar, D.; Brown, A.; Brugger, M.; Caamaño, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Capote, R.; Cardella, R.; Carrapiço, C.; Casanovas, A.; Castelluccio, D. M.; Cennini, P.; Cerutti, F.; Chen, Y. H.; Chiaveri, E.; Chin, M.; Colonna, N.; Cortés, G.; Cortés-Giraldo, M. A.; Cosentino, L.; Couture, A.; Cox, J.; Damone, L. A.; David, S.; Deo, K.; Diakaki, M.; Dillmann, I.; Domingo-Pardo, C.; Dressler, R.; Dridi, W.; Duran, I.; Eleftheriadis, C.; Embid-Segura, M.; Fernández-Domínguez, B.; Ferrant, L.; Ferrari, A.; Ferreira, P.; Finocchiaro, P.; Fraval, K.; Frost, R. J. W.; Fujii, K.; Furman, W.; Ganesan, S.; Garcia, A. R.; Gawlik, A.; Gheorghe, I.; Gilardoni, S.; Giubrone, G.; Glodariu, T.; Göbel, K.; Gomez-Hornillos, M. B.; Goncalves, I. F.; Gonzalez-Romero, E.; Goverdovski, A.; Gramegna, F.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Gurusamy, P.; Haight, R.; Harada, H.; Heftrich, T.; Heil, M.; Heinitz, S.; Hernández-Prieto, A.; Heyse, J.; Igashira, M.; Isaev, S.; Jenkins, D. G.; Jericha, E.; Kadi, Y.; Kaeppeler, F.; Kalamara, A.; Karadimos, D.; Karamanis, D.; Katabuchi, T.; Kavrigin, P.; Kerveno, M.; Ketlerov, V.; Khryachkov, V.; Kimura, A.; Kivel, N.; Kokkoris, M.; Konovalov, V.; Krtička, M.; Kroll, J.; Kurtulgil, D.; Lampoudis, C.; Langer, C.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Naour, C. Le; Lerendegui-Marco, J.; Leong, L. S.; Licata, M.; Meo, S. Lo; Lonsdale, S. J.; Losito, R.; Lozano, M.; Macina, D.; Manousos, A.; Marganiec, J.; Martinez, T.; Marrone, S.; Masi, A.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Matteucci, F.; Maugeri, E. A.; Mazzone, A.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Mondelaers, W.; Montesano, S.; Moreau, C.; Mosconi, M.; Musumarra, A.; Negret, A.; Nolte, R.; O'Brien, S.; Oprea, A.; Palomo-Pinto, F. R.; Pancin, J.; Paradela, C.; Patronis, N.; Pavlik, A.; Pavlopoulos, P.; Perkowski, J.; Perrot, L.; Pigni, M. T.; Plag, R.; Plompen, A.; Plukis, L.; Poch, A.; Porras, I.; Praena, J.; Pretel, C.; Quesada, J. M.; Radeck, D.; Rajeev, K.; Rauscher, T.; Reifarth, R.; Riego, A.; Robles, M.; Roman, F.; Rout, P. C.; Rudolf, G.; Rubbia, C.; Rullhusen, P.; Ryan, J. A.; Sabaté-Gilarte, M.; Salgado, J.; Santos, C.; Sarchiapone, L.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Sedyshev, P.; Smith, A. G.; Sosnin, N. V.; Stamatopoulos, A.; Stephan, C.; Suryanarayana, S. V.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tarrío, D.; Tassan-Got, L.; Tavora, L.; Terlizzi, R.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Versaci, R.; Vermeulen, M. J.; Villamarin, D.; Vicente, M. C.; Vlachoudis, V.; Vlastou, R.; Voss, F.; Wallner, A.; Walter, S.; Ware, T.; Warren, S.; Weigand, M.; Weiß, C.; Wolf, C.; Wiesher, M.; Wisshak, K.; Woods, P. J.; Wright, T.; Žugec, P.

    2017-09-01

    The n_TOF neutron time-of-flight facility at CERN is used for high quality nuclear data measurements from thermal energy up to hundreds of MeV. In line with the CERN open data policy, the n_TOF Collaboration takes actions to preserve its unique data, facilitate access to them in standardised format, and allow their re-use by a wide community in the fields of nuclear physics, nuclear astrophysics and various nuclear technologies. The present contribution briefly describes the n_TOF outcomes, as well as the status of dissemination and preservation of n_TOF final data in the international EXFOR library.

  5. Dissemination of data measured at the CERN n_TOF facility

    Directory of Open Access Journals (Sweden)

    Dupont E.

    2017-01-01

    Full Text Available The n_TOF neutron time-of-flight facility at CERN is used for high quality nuclear data measurements from thermal energy up to hundreds of MeV. In line with the CERN open data policy, the n_TOF Collaboration takes actions to preserve its unique data, facilitate access to them in standardised format, and allow their re-use by a wide community in the fields of nuclear physics, nuclear astrophysics and various nuclear technologies. The present contribution briefly describes the n_TOF outcomes, as well as the status of dissemination and preservation of n_TOF final data in the international EXFOR library.

  6. submitter Dissemination of data measured at the CERN n_TOF facility

    CERN Document Server

    Dupont, E; Cabellos, O; Aberle, O; Aerts, G; Altstadt, S; Alvarez, H; Alvarez-Velarde, F; Andriamonje, S; Andrzejewski, J; Audouin, L; Bacak, M; Badurek, G; Balibrea, J; Barbagallo, M; Barros, S; Baumann, P; Bécares, V; Bečvář, F; Beinrucker, C; Belloni, F; Berthier, B; Berthoumieux, E; Billowes, J; Boccone, V; Bosnar, D; Brown, A; Brugger, M; Caamaño, M; Calviani, M; Calviño, F; Cano-Ott, D; Capote, R; Cardella, R; Carrapiço, C; Casanovas, A; Castelluccio, D M; Cennini, P; Cerutti, F; Chen, Y H; Chiaveri, E; Chin, M; Colonna, N; Cortés, G; Cortés-Giraldo, M A; Cosentino, L; Couture, A; Cox, J; Damone, L A; David, S; Deo, K; Diakaki, M; Dillmann, I; Domingo-Pardo, C; Dressler, R; Dridi, W; Duran, I; Eleftheriadis, C; Embid-Segura, M; Fernández-Domínguez, B; Ferrant, L; Ferrari, A; Ferreira, P; Finocchiaro, P; Fraval, K; Frost, R J W; Fujii, K; Furman, W; Ganesan, S; Garcia, A R; Gawlik, A; Gheorghe, I; Gilardoni, S; Giubrone, G; Glodariu, T; Göbel, K; Gomez-Hornillos, M B; Goncalves, I F; Gonzalez-Romero, E; Goverdovski, A; Gramegna, F; Griesmayer, E; Guerrero, C; Gunsing, F; Gurusamy, P; Haight, R; Harada, H; Heftrich, T; Heil, M; Heinitz, S; Hernández-Prieto, A; Heyse, J; Igashira, M; Isaev, S; Jenkins, D G; Jericha, E; Kadi, Y; Kaeppeler, F; Kalamara, A; Karadimos, D; Karamanis, D; Katabuchi, T; Kavrigin, P; Kerveno, M; Ketlerov, V; Khryachkov, V; Kimura, A; Kivel, N; Kokkoris, M; Konovalov, V; Krtička, M; Kroll, J; Kurtulgil, D; Lampoudis, C; Langer, C; Leal-Cidoncha, E; Lederer, C; Leeb, H; Le Naour, C; Lerendegui-Marco, J; Leong, L S; Licata, M; Lo Meo, S; Lonsdale, S J; Losito, R; Lozano, M; Macina, D; Manousos, A; Marganiec, J; Martinez, T; Marrone, S; Masi, A; Massimi, C; Mastinu, P; Mastromarco, M; Matteucci, F; Maugeri, E A; Mazzone, A; Mendoza, E; Mengoni, A; Milazzo, P M; Mingrone, F; Mirea, M; Mondelaers, W; Montesano, S; Moreau, C; Mosconi, M; Musumarra, A; Negret, A; Nolte, R; O'Brien, S; Oprea, A; Palomo-Pinto, F R; Pancin, J; Paradela, C; Patronis, N; Pavlik, A; Pavlopoulos, P; Perkowski, J; Perrot, L; Pigni, M T; Plag, R; Plompen, A; Plukis, L; Poch, A; Porras, I; Praena, J; Pretel, C; Quesada, J M; Radeck, D; Rajeev, K; Rauscher, T; Reifarth, R; Riego, A; Robles, M; Roman, F; Rout, P C; Rudolf, G; Rubbia, C; Rullhusen, P; Ryan, J A; Sabaté-Gilarte, M; Salgado, J; Santos, C; Sarchiapone, L; Sarmento, R; Saxena, A; Schillebeeckx, P; Schmidt, S; Schumann, D; Sedyshev, P; Smith, A G; Sosnin, N V; Stamatopoulos, A; Stephan, C; Suryanarayana, S V; Tagliente, G; Tain, J L; Tarifeño-Saldivia, A; Tarrío, D; Tassan-Got, L; Tavora, L; Terlizzi, R; Tsinganis, A; Valenta, S; Vannini, G; Variale, V; Vaz, P; Ventura, A; Versaci, R; Vermeulen, M J; Villamarin, D; Vicente, M C; Vlachoudis, V; Vlastou, R; Voss, F; Wallner, A; Walter, S; Ware, T; Warren, S; Weigand, M; Weiß, C; Wolf, C; Wiesher, M; Wisshak, K; Woods, P J; Wright, T; Žugec, P

    2017-01-01

    The n_TOF neutron time-of-flight facility at CERN is used for high quality nuclear data measurements from thermal energy up to hundreds of MeV. In line with the CERN open data policy, the n_TOF Collaboration takes actions to preserve its unique data, facilitate access to them in standardised format, and allow their re-use by a wide community in the fields of nuclear physics, nuclear astrophysics and various nuclear technologies. The present contribution briefly describes the n_TOF outcomes, as well as the status of dissemination and preservation of n_TOF final data in the international EXFOR library.

  7. Recent Results In Nuclear Astrophysics At The n_TOF Facility At CERN

    CERN Document Server

    Tagliente, Giuseppe; Andrzejewski, J; Audouin, L; Bacak, M; Balibrea, J; Barbagallo, M; Bečvář, F; Berthoumieux, E; Billowes, J; Bosnar, D; Brown, A; Caamaño, M; Calviño, F; Calviani, M; Cano-Ott, D; Cardella, R; Casanovas, A; Cerutti, F; Chen, Y H; Chiaveri, E; Colonna, N; Cortés, G; Cortés-Giraldo, M A; Cosentino; Damone, L A; Diakaki, M; Domingo-Pardo, C; Dressler, L R; Dupont, E; Durán, I; Fernández-Domínguez, B; Ferrari, A; Ferreira, P; Finocchiaro, P; Furman, V; Göbel, K; García, A R; Gawlik, A; Gilardoni, S; Glodariu, T; Gonçalves, I F; González, E; Griesmayer, E; Guerrero, C; Gunsing, F; Harada, H; Heinitz, S; Heyse, J; Jenkins, D G; Jericha, E; Käppeler, F; Kadi, Y; Kalamara, A; Kavrigin, P; Kimura, A; Kivel, N; Kokkoris, M; Krtička, M; Kurtulgil, D; Leal-Cidoncha, E; Lederer, C; Lerendegui-Marco, J; Leeb, H; Lo Meo, S; Lonsdale, S J; Macina, D; Marganiec, J; Martínez, T; Masi, A; Massimi, C; Mastinu, P; Mastromarco, M; Maugeri, E A; Mazzone, A; Mendoza, E; Mengoni, A; Mingrone, F; Milazzo, P M; Musumarra, A; Negret, A; Nolte, R; Oprea, A; Patronis, N; Pavlik, A; Perkowski, J; Porras, I; Praena, J; Quesada, J M; Radeck, D; Rauscher, T; Reifarth, R; Rubbia, C; Ryan, J A; Sabaté-Gilarte, M; Saxena, A; Schillebeeckx, P; Schumann, D; Sedyshev, P; Smith, A G; Sosnin, N V; Stamatopoulos, A; Tain, J L; Tarifeño-Saldivia, A; Valenta, S; Vannini, G; Variale, V; Vaz, P; Ventura, A; Vlachoudis, V; Vlastou, R; Wallner, A; Warren, S; Woods, P J; Żugec, P Č

    2017-01-01

    The neutron time of flight (n_TOF) facility at CERN is a spallation source characterized by a white neutron spectrum. The innovative features of the facility, in the two experimental areas, (20 m and 185 m), allow for an accurate determination of the neutron cross section for radioactive samples or for isotopes with small neutron capture cross section, of interest for Nuclear Astrophysics. The recent results obtained at n_TOF facility are presented.

  8. The n_TOF facility: Neutron beams for challenging future measurements at CERN

    Science.gov (United States)

    Chiaveri, E.; Aberle, O.; Andrzejewski, J.; Audouin, L.; Bacak, M.; Balibrea, J.; Barbagallo, M.; Bečvář, F.; Berthoumieux, E.; Billowes, J.; Bosnar, D.; Brown, A.; Caamaño, M.; Calviño, F.; Calviani, M.; Cano-Ott, D.; Cardella, R.; Casanovas, A.; Cerutti, F.; Chen, Y. H.; Colonna, N.; Cortés, G.; Cortés-Giraldo, M. A.; Cosentino, L.; Damone, L. A.; Diakaki, M.; Domingo-Pardo, C.; Dressler, R.; Dupont, E.; Durán, I.; Fernández-Domínguez, B.; Ferrari, A.; Ferreira, P.; Finocchiaro, P.; Göbel, K.; García, A. R.; Gawlik, A.; Gilardoni, S.; Glodariu, T.; Gonçalves, I. F.; González, E.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Harada, H.; Heinitz, S.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Kalamara, A.; Kavrigin, P.; Kimura, A.; Kivel, N.; Kokkoris, M.; Krtička, M.; Kurtulgil, D.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Lerendegui-Marco, J.; Meo, S. Lo; Lonsdale, S. J.; Macina, D.; Marganiec, J.; Martínez, T.; Masi, A.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Maugeri, E. A.; Mazzone, A.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Musumarra, A.; Negret, A.; Nolte, R.; Oprea, A.; Patronis, N.; Pavlik, A.; Perkowski, J.; Porras, I.; Praena, J.; Quesada, J. M.; Radeck, D.; Rauscher, T.; Reifarth, R.; Rubbia, C.; Ryan, J. A.; Sabaté-Gilarte, M.; Saxena, A.; Schillebeeckx, P.; Schumann, D.; Smith, A. G.; Sosnin, N. V.; Stamatopoulos, A.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Warren, S.; Woods, P. J.; Wright, T.; Žugec, P.

    2017-09-01

    The CERN n_TOF neutron beam facility is characterized by a very high instantaneous neutron flux, excellent TOF resolution at the 185 m long flight path (EAR-1), low intrinsic background and coverage of a wide range of neutron energies, from thermal to a few GeV. These characteristics provide a unique possibility to perform high-accuracy measurements of neutron-induced reaction cross-sections and angular distributions of interest for fundamental and applied Nuclear Physics. Since 2001, the n_TOF Collaboration has collected a wealth of high quality nuclear data relevant for nuclear astrophysics, nuclear reactor technology, nuclear medicine, etc. The overall efficiency of the experimental program and the range of possible measurements has been expanded with the construction of a second experimental area (EAR-2), located 20 m on the vertical of the n_TOF spallation target. This upgrade, which benefits from a neutron flux 30 times higher than in EAR-1, provides a substantial extension in measurement capabilities, opening the possibility to collect data on neutron cross-section of isotopes with short half-lives or available in very small amounts. This contribution will outline the main characteristics of the n_TOF facility, with special emphasis on the new experimental area. In particular, we will discuss the innovative features of the EAR-2 neutron beam that make possible to perform very challenging measurements on short-lived radioisotopes or sub-mg samples, out of reach up to now at other neutron facilities around the world. Finally, the future perspectives of the facility will be presented.

  9. The CERN n_TOF Facility: Neutron Beams Performances for Cross Section Measurements

    CERN Document Server

    Chiaveri, E; Andrzejewski, J; Audouin, L; Barbagallo, M; Bécares, V; Bečvář, F; Belloni, F; Berthoumieux, E; Billowes, J; Boccone, V; Bosnar, D; Brugger, M; Calviani, M; Calviño, F; Cano-Ott, D; Carrapiço, C; Cerutti, F; Chin, M; Colonna, N; Cortés, G; Cortés-Giraldo, M A; Diakaki, M; Domingo-Pardo, C; Duran, I; Dressler, R; Dzysiuk, N; Eleftheriadis, C; Ferrari, A; Fraval, K; Ganesan, S; García, A R; Giubrone, G; Gómez-Hornillos, M B; Gonçalves, I F; González-Romero, E; Griesmayer, E; Guerrero, C; Gunsing, F; Gurusamy, P; Hernández-Prieto, A; Jenkins, D G; Jericha, E; Kadi, Y; Käppeler, F; Karadimos, D; Kivel, N; Koehler, P; Kokkoris, M; Krtička, M; Kroll, J; Lampoudis, C; Langer, C; Leal-Cidoncha, E; Lederer, C; Leeb, H; Leong, L S; Losito, R; Mallick, A; Manousos, A; Marganiec, J; Martínez, T; Massimi, C; Mastinu, P F; Mastromarco, M; Meaze, M; Mendoza, E; Mengoni, A; Milazzo, P M; Mingrone, F; Mirea, M; Mondalaers, W; Paradela, C; Pavlik, A; Perkowski, J; Plompen, A; Praena, J; Quesada, J M; Rauscher, T; Reifarth, R; Riego, A; Robles, M S; Roman, F; Rubbia, C; Sabaté-Gilarte, M; Sarmento, R; Saxena, A; Schillebeeckx, P; Schmidt, S; Schumann, D; Tagliente, G; Tain, J L; Tarrío, D; Tassan-Got, L; Tsinganis, A; Valenta, S; Vannini, G; Variale, V; Vaz, P; Ventura, A; Versaci, R; Vermeulen, M J; Vlachoudis, V; Vlastou, R; Wallner, A; Ware, T; Weigand, M; Weiss, C; Wright, T; Žugec, P

    2014-01-01

    This paper presents the characteristics of the existing CERN n\\_TOF neutron beam facility (n\\_TOF-EAR1 with a flight path of 185 meters) and the future one (n\\_TOF EAR-2 with a flight path of 19 meters), which will operate in parallel from Summer 2014. The new neutron beam will provide a 25 times higher neutron flux delivered in 10 times shorter neutron pulses, thus offering more powerful capabilities for measuring small mass, low cross section and/or high activity samples.

  10. The present status of the n-TOF facility at CERN

    International Nuclear Information System (INIS)

    Igashira, Masayuki

    2005-01-01

    The main aim of the n - TOF facility at CERN is to provide precise neutron cross-section data relevant to the R and D of accelerator driven systems, nuclear astrophysics, etc. It is composed of a spallation neutron source, a 187.5-m flight path, a variety of detectors, a data acquisition system, etc. A 20 GeV proton synchrotron is employed together with a lead target for the spallation neutron source. The measurement of capture and fission cross sections started in 2002 and had been performed until the mid of November in 2004. The capture and fission measurements were performed for 28 and 7 isotopes, respectively. The brief history, present status, and future plan of the n - TOF facility are reported. (author)

  11. Happy birthday n_TOF!

    CERN Multimedia

    Francesco Poppi

    2010-01-01

    The “Neutron Time Of Flight” facility (n_TOF) has recently turned ten. A simple ceremony marked the date of the anniversary and provides a nice opportunity to retrace the successful history of this unique facility, whose scientific activity spans a range from astrophysics to the study of nuclear-waste transmutation processes.   From left to right: Enrique Gonzalez-Romero, Chairman of Collaboration Board, Enrico Chiaveri, Spokesperson of n_TOF Experiment, and Carlo Rubbia, the creator of the n_TOF experiment. Ten years after its first beam, n_TOF is just approaching maturity. Revitalized by the recent renovation of its infrastructures that allowed it to gain the unique label of “Class A” in radio-protection standards, n_TOF has a rich and challenging scientific programme. “One year ago, the beam line and the experimental area were completely rebuilt to comply with the Class A radio protection requirements in order to safely use almost all radionucl...

  12. Article n_TOF : rectificatif

    CERN Multimedia

    2008-01-01

    Une erreur s’est malencontreusement glissée dans la version française de la dernière édition du Bulletin papier. L’introduction (en gras) de l’article « Les neutrons sur la piste de décollage » était celle de l’article sur le Linac 4 paru dans l’édition précédente. Le paragraphe correct est le suivant : « Au repos depuis quatre ans, les neutrons volent à nouveau dans l’installation n_TOF (mesure du temps de vol des neutrons), qui vient d’être remise en service avec une nouvelle cible. » Veuillez nous excuser pour cette erreur.

  13. Applied physics measurements at the CERN n-TOF facility

    CERN Document Server

    González, E

    2002-01-01

    The present experimental program of the recently constructed neutron time-of-flight installation at CERN, n_TOF, is dominated by the objectives of a shared cost action project of the EU for the measurement of neutron cross section needed for ADS development and nuclear waste transmutation, nTOF-ADS. This paper presents the motivations and the list of reactions and isotopes considered in this part of the n_TOF program. The experimental methods and the present measurement schedule are also briefly discussed. (7 refs).

  14. The 236U neutron capture cross-section measured at the n_TOF CERN facility

    Directory of Open Access Journals (Sweden)

    Mastromarco M.

    2017-01-01

    Full Text Available The 236U isotope plays an important role in nuclear systems, both for future and currently operating ones. The actual knowledge of the capture reaction of this isotope is satisfactory in the thermal region, but it is considered insufficient for Fast Reactor and ADS applications. For this reason the 236U(n, γ reaction cross-section has been measured for the first time in the whole energy region from thermal energy up to 1 MeV at the n_TOF facility with two different detection systems: an array of C6D6 detectors, employing the total energy deposited method, and a FX1 total absorption calorimeter (TAC, made of 40 BaF2 crystals. The two n_TOF data sets agree with each other within the statistical uncertainty in the Resolved Resonance Region up to 800 eV, while sizable differences (up to ≃ 20% are found relative to the current evaluated data libraries. Moreover two new resonances have been found in the n_TOF data. In the Unresolved Resonance Region up to 200 keV, the n_TOF results show a reasonable agreement with previous measurements and evaluated data.

  15. CERN n_TOF Facility: Performance Report

    CERN Document Server

    n_TOF, Collaboration

    2003-01-01

    This report describes the basic characteristics and the performances of the new neutron time-of-flight facility, n_TOF, recently set in operation at CERN. The report is divided into three parts. In the first part, a description of the characteristics of the installation, up to the experimental area (EAR-1) is presented. This includes the proton extraction line from the PS, the spallation module (the lead target and its cooling and moderation systems) and the neutron beam window. A description of the neutron time-of-flight line with the vacuum system, shielding and collimation is also included in this part. In the second part, matters related to safety issues, including radiation and dose estimates and measurements in the target area are discussed. In the third part, a description of the experimental set up in EAR-1 is presented. This includes the data acquisition systems, the beam monitoring systems and the detectors for capture and for fission measurements. The measurements performed in order to derive the m...

  16. Study of 234U(n,f) Resonances Measured at the CERN n_TOF Facility

    CERN Document Server

    Leal-Cidoncha, E; Paradela, C; Tarrío, D; Leong, L S; Audouin, L; Tassan-Got, L; Praena, J; Berthier, B; Ferrant, L; Isaev, S; Le Naour, C; Stephan, C; Trubert, D; Abbondanno, U; Aerts, G; Álvarez, H; Álvarez-Velarde, F; Andriamonje, S; Andrzejewski, J; Badurek, G; Baumann, P; Bečvář, F; Berthoumieux, E; Calviño, F; Calviani, M; Cano-Ott, D; Capote, R; Carrapiço, C; Cennini, P.; Chepel, V; Chiaveri, E.; Colonna, N; Cortes, G; Couture, A; Cox, J; Dahlfors, M; David, S.; Dillmann, I; Domingo-Pardo, C; Dridi, W; Eleftheriadis, C; Embid-Segura, M; Ferrari, A.; Ferreira-Marques, R; Fujii, K; Furman, W; Gonçalves, I; González-Romero, E; Gramegna, F; Guerrero, C; Gunsing, F; Haas, B; Haight, R; Heil, M; Herrera-Martinez, A.; Igashira, M; Jericha, E; Kadi, Y.; Käppeler, F; Karadimos, D; Kerveno, M; Koehler, P; Kossionides, E; Krtička, M; Lampoudis, C; Leeb, H; Lindote, A; Lopes, I; Lozano, M; Lukic, S; Marganiec, J; Marrone, S; Martínez, T; Massimi, C; Mastinu, P; Mengoni, A; Milazzo, P M; Moreau, C; Mosconi, M; Neves, F; Oberhummer, H; O'Brien, S; Oshima, M; Pancin, J; Papadopoulos, C; Pavlik, A; Pavlopoulos, P.; Perrot, L; Pigni, M T; Plag, R; Plompen, A; Plukis, A; Poch, A; Pretel, C; Quesada, J; Rauscher, T.; Reifarth, R; Rubbia, C.; Rudolf, G; Rullhusen, P; Salgado, J; Santos, C; Sarchiapone, L.; Savvidis, I; Tagliente, G; Tain, J L; Tavora, L; Terlizzi, R; Vannini, G; Vaz, P; Ventura, A.; Villamarin, D; Vincente, M C; Vlachoudis, V.; Vlastou, R; Voss, F; Walter, S; Wiescher, M; Wisshak, K

    2014-01-01

    We present the analysis of the resolved resonance region for the U-234(n,f) cross section data measured at the CERN n\\_TOF facility. The resonance parameters in the energy range from 1 eV to 1500 eV have been obtained with the SAMMY code by using as initial parameters for the fit the resonance parameters of the JENDL-3.3 evaluation. In addition, the statistical analysis has been accomplished, partly with the SAMDIST code, in order to study the level spacing and the Mehta-Dyson correlation.

  17. A Micromegas Detector for Neutron Beam Imaging at the n_TOF Facility at CERN

    CERN Document Server

    Belloni, F; Berthoumieux, E; Calviani, M; Chiaveri, E; Colonna, N; Giomataris, Y; Guerrero, C; Gunsing, F; Iguaz, F J; Kebbiri, M; Pancin, J; Papaevangelou, T; Tsinganis, A; Vlachoudis, V; Altstadt, S; Andrzejewski, J; Audouin, L; Barbagallo, M; Bécares, V; Bečvář, F; Billowes, J; Boccone, V; Bosnar, D; Brugger, M; Calviño, F; Cano-Ott, D; Carrapiço, C; Cerutti, F; Chiaveri, E; Chin, M; Cortés, G; Corté-Giraldo, M A; Diakaki, M; Domingo-Pardo, C; Duran, I; Dzysiuk, N; Eleftheriadis, C; Ferrari, A; Fraval, K; Ganesan, S; García, A R; Giubrone, G; Gómez-Hornillos, M B; Gonçalves, I F; González-Romero, E; Griesmayer, E; Gurusamy, P; Jenkins, D G; Jericha, E; Kadi, Y; Käppeler, F; Karadimos, D; Koehler, P; Kokkoris, M; Krtička, M; Kroll, J; Langer, C; Lederer, C; Leeb, H; Leong, L S; Losito, R; Manousos, A; Marganiec, J; Marítnez, T; Massimi, C; Mastinu, P F; Mastromarco, M; Meaze, M; Mendoza, E; Mengoni, A; Milazzo, P M; Mingrone, F; Mirea, M; Mondalaers, W; Paradela, C; Pavlik, A; Perkowski, J; Plompen, A J M; Praena, J; Quesada, J M; Rauscher, T; Reifarth, R; Riego, A; Roman, F; Rubbia, C; Sarmento, R; Schillebeeckx, P; Schmidt, S; Tagliente, G; Tain, J L; Tarrío, D; Tassan-Got, L; Valenta, S; Vannini, G; Variale, V; Vaz, P; Ventura, A; Versaci, R; Vermeulen, M J; Vlastou, R; Wallner, A; Ware, T; Weigand, M; Weiss, C; Wright, T J; Žugec, P

    2014-01-01

    Micromegas (Micro-MEsh Gaseous Structure) detectors are gas detectors consisting of a stack of one ionization and one proportional chamber. A micromesh separates the two communicating regions, where two different electric fields establish respectively a charge drift and a charge multiplication regime. The n\\_TOF facility at CERN provides a white neutron beam (from thermal up to GeV neutrons) for neutron induced cross section measurements. These measurements need a perfect knowlodge of the incident neutron beam, in particular regarding its spatial profile. A position sensitive micromegas detector equipped with a B-10 based neutron/charged particle converter has been extensively used at the n\\_TOF facility for characterizing the neutron beam profile and extracting the beam interception factor for samples of different size. The boron converter allowed to scan the energy region of interest for neutron induced capture reactions as a function of the neutron energy, determined by the time of flight. Experimental ...

  18. The measurement programme at the neutron time-of-flight facility n_TOF at CERN

    Directory of Open Access Journals (Sweden)

    Gunsing F.

    2017-01-01

    Full Text Available Neutron-induced reaction cross sections are important for a wide variety of research fields ranging from the study of nuclear level densities, nucleosynthesis to applications of nuclear technology like design, and criticality and safety assessment of existing and future nuclear reactors, radiation dosimetry, medical applications, nuclear waste transmutation, accelerator-driven systems and fuel cycle investigations. Simulations and calculations of nuclear technology applications largely rely on evaluated nuclear data libraries. The evaluations in these libraries are based both on experimental data and theoretical models. CERN’s neutron time-of-flight facility n_TOF has produced a considerable amount of experimental data since it has become fully operational with the start of its scientific measurement programme in 2001. While for a long period a single measurement station (EAR1 located at 185 m from the neutron production target was available, the construction of a second beam line at 20 m (EAR2 in 2014 has substantially increased the measurement capabilities of the facility. An outline of the experimental nuclear data activities at n_TOF will be presented.

  19. "7Be(n,α) "7Be(n,p) cross-section measurement for the Cosmological Lithium Problem at the n_TOF facility at CERN

    International Nuclear Information System (INIS)

    Barbagallo, M.

    2016-01-01

    The "7Be(n,α) reaction cross-section has been measured for the first time in a wide neutron energy range, in order to investigate its role in the destruction of "7Be during Big Bang Nucleosynthesis, as a possible solution to the Cosmological Lithium problem (CLiP). The measurement has been performed at the new vertical beam line of the neutron Time-of-Flight facility (n TOF) at CERN, taking advantage of the extremely high instantaneous neutron flux which allows to obtain the useful signal-to-background ratio particularly suited for challenging measurements on short-lived radioisotopes, such as "7Be (t_1_/_2 ≃ 53.2days). The two alfa particles emitted back-to-back in the reaction have been detected by mean of sandwiches of silicon detectors and exploiting the coincidence technique. In order to complete the n TOF program on CLiP, the "7Be(n,p) cross-section will be measured during the next n TOF experimental campaign, using an high-purity sample and a silicon telescope device.

  20. Ni62(n,γ) and Ni63(n,γ) cross sections measured at the n_TOF facility at CERN

    Science.gov (United States)

    Lederer, C.; Massimi, C.; Berthoumieux, E.; Colonna, N.; Dressler, R.; Guerrero, C.; Gunsing, F.; Käppeler, F.; Kivel, N.; Pignatari, M.; Reifarth, R.; Schumann, D.; Wallner, A.; Altstadt, S.; Andriamonje, S.; Andrzejewski, J.; Audouin, L.; Barbagallo, M.; Bécares, V.; Bečvář, F.; Belloni, F.; Berthier, B.; Billowes, J.; Boccone, V.; Bosnar, D.; Brugger, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Cortés, G.; Cortés-Giraldo, M. A.; Dillmann, I.; Domingo-Pardo, C.; Duran, I.; Dzysiuk, N.; Eleftheriadis, C.; Fernández-Ordóñez, M.; Ferrari, A.; Fraval, K.; Ganesan, S.; García, A. R.; Giubrone, G.; Gómez-Hornillos, M. B.; Gonçalves, I. F.; González-Romero, E.; Gramegna, F.; Griesmayer, E.; Gurusamy, P.; Harrisopulos, S.; Heil, M.; Ioannides, K.; Jenkins, D. G.; Jericha, E.; Kadi, Y.; Karadimos, D.; Korschinek, G.; Krtička, M.; Kroll, J.; Langer, C.; Lebbos, E.; Leeb, H.; Leong, L. S.; Losito, R.; Lozano, M.; Manousos, A.; Marganiec, J.; Marrone, S.; Martinez, T.; Mastinu, P. F.; Mastromarco, M.; Meaze, M.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Mondalaers, W.; Paradela, C.; Pavlik, A.; Perkowski, J.; Plag, R.; Plompen, A.; Praena, J.; Quesada, J. M.; Rauscher, T.; Riego, A.; Roman, F.; Rubbia, C.; Sarmento, R.; Schillebeeckx, P.; Schmidt, S.; Tagliente, G.; Tain, J. L.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Tlustos, L.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vermeulen, M. J.; Versaci, R.; Vlachoudis, V.; Vlastou, R.; Ware, T.; Weigand, M.; Weiß, C.; Wright, T. J.; Žugec, P.; n TOF Collaboration

    2014-02-01

    The cross section of the Ni62(n,γ) reaction was measured with the time-of-flight technique at the neutron time-of-flight facility n_TOF at CERN. Capture kernels of 42 resonances were analyzed up to 200 keV neutron energy and Maxwellian averaged cross sections (MACS) from kT = 5-100 keV were calculated. With a total uncertainty of 4.5%, the stellar cross section is in excellent agreement with the the KADoNiS compilation at kT=30 keV, while being systematically lower up to a factor of 1.6 at higher stellar temperatures. The cross section of the Ni63(n ,γ) reaction was measured for the first time at n_TOF. We determined unresolved cross sections from 10 to 270 keV with a systematic uncertainty of 17%. These results provide fundamental constraints on s-process production of heavier species, especially the production of Cu in massive stars, which serve as the dominant source of Cu in the solar system.

  1. Fission Cross-section Measurements of (233)U, (245)Cm and (241,243)Am at CERN n_TOF Facility

    CERN Document Server

    Calviani, M; Andriamonje, S; Chiaveri, E; Vlachoudis, V; Colonna, N; Meaze, M H; Marrone, S; Tagliente, G; Terlizzi, R; Belloni, F; Abbondanno, U; Fujii, K; Milazzo, P M; Moreau, C; Aerts, G; Berthoumieux, E; Dridi, W; Gunsing, F; Pancin, J; Perrot, L; Plukis, A; Alvarez, H; Duran, I; Paradela, C; Alvarez-Velarde, F; Cano-Ott, D; Gonzalez-Romero, E; Guerrero, C; Martinez, T; Villamarin, D; Vicente, M C; Andrzejewski, J; Marganiec, J; Assimakopoulos, P; Karadimos, D; Karamanis, D; Papachristodoulou, C; Patronis, N; Audouin, L; David, S; Ferrant, L; Isaev, S; Stephan, C; Tassan-Got, L; Badurek, G; Jericha, E; Leeb, H; Oberhummer, H; Pigni, M T; Baumann, P; Kerveno, M; Lukic, S; Rudolf, G; Becvar, F; Krticka, M; Calvino, F; Capote, R; Carrillo De Albornoz, A; Marques, L; Salgado, J; Tavora, L; Vaz, P; Cennini, P; Dahlfors, M; Ferrari, A; Gramegna, F; Herrera-Martinez, A; Kadi, Y; Mastinu, P; Praena, J; Sarchiapone, L; Wendler, H; Chepel, V; Ferreira-Marques, R; Goncalves, I; Lindote, A; Lopes, I; Neves, F; Cortes, G; Poch, A; Pretel, C; Couture, A; Cox, J; O'brien, S; Wiescher, M; Dillman, I; Heil, M; Kappeler, F; Mosconi, M; Plag, R; Voss, F; Walter, S; Wisshak, K; Dolfini, R; Rubbia, C; Domingo-Pardo, C; Tain, J L; Eleftheriadis, C; Savvidis, I; Frais-Koelbl, H; Griesmayer, E; Furman, W; Konovalov, V; Goverdovski, A; Ketlerov, V; Haas, B; Haight, R; Reifarth, R; Igashira, M; Koehler, P; Kossionides, E; Lampoudis, C; Lozano, M; Quesada, J; Massimi, C; Vannini, G; Mengoni, A; Oshima, M; Papadopoulos, C; Vlastou, R; Pavlik, A; Pavlopoulos, P; Plompen, A; Rullhusen, P; Rauscher, T; Rosetti, M; Ventura, A

    2011-01-01

    Neutron-induced fission cross-sections of minor actinides have been measured using the n_TOF white neutron source at CERN, Geneva, as part of a large experimental program aiming at collecting new data relevant for nuclear astrophysics and for the design of advanced reactor systems. The measurements at n_TOF take advantage of the innovative features of the n_TOF facility, namely the wide energy range, high instantaneous neutron flux and good energy resolution. Final results on the fission cross-section of 233U, 245Cm and 243Am from thermal to 20 MeV are here reported, together with preliminary results for 241Am. The measurement have been performed with a dedicated Fast Ionization Chamber (FIC), a fission fragment detector with a very high efficiency, relative to the very well known cross-section of 235U, measured simultaneously with the same detector.

  2. Measurement of cross-sections of fission reactions induced by neutrons on actinides from the thorium cycle at n-TOF facility; Mesures de sections efficaces de fission induite par neutrons sur des actinides du cycle du thorium a n-TOF

    Energy Technology Data Exchange (ETDEWEB)

    Ferrant, L

    2005-09-01

    In the frame of innovating energy source system studies, thorium fuel cycle reactors are considered. Neutron induced fission cross section on such cycle involved actinides play a role in scenario studies. To feed them, data bases are built with experimental results and nuclear models. For some nuclei, they are not complete or in disagreement. In order to complete these data bases, we have built an original set up, consisting in an alternation of PPACs (Parallel Plate Avalanche Chamber) and ultra - thin targets, which we installed on n-TOF facility. We describe detectors, set up, and the particular care brought to target making and characterization. Fission products in coincidence are detected with precise time measurement and localization with delay line read out method. We contributed, within the n-TOF collaboration, to the CERN brand new intense spallation neutron source characterization, based on time of flight measurement, and we describe its characteristics and performances. We were able to measure such actinide fission cross sections as {sup 232}Th, {sup 234}U, {sup 233}U, {sup 237}Np, {sup 209}Bi, and {sup nat}Pb relative to {sup 235}U et {sup 238}U standards, using an innovative acquisition system. We took advantage of the lame accessible energy field, from 0.7 eV to 1 GeV, combined with the excellent energy resolution in this field. Data treatment and analysis advancement are described to enlighten performance and limits of the obtained results. (author)

  3. Measurement of the $^{242}$Pu(n,f) reaction cross-section at the CERN n_TOF facility

    CERN Document Server

    AUTHOR|(CDS)2080481; Kokkoris, Michael; Vlachoudis, Vasilis

    The accurate knowledge of relevant nuclear data, such as the neutron-induced fission cross sections of various plutonium isotopes and other minor actinides, is crucial for the design of advanced nuclear systems as well as the development of comprehensive theoretical models of the fission process. The $^{242}$Pu(n,f) cross section was measured at the CERN n_TOF facility taking advantage of the wide energy range and the high instantaneous flux of the neutron beam. In this work, results for the $^{242}$Pu(n,f) measurement are presented along with a detailed description of the experimental setup, Monte-Carlo simulations and the analysis procedure, and a theoretical cross section calculation performed with the EMPIRE code.

  4. The data acquisition system of the neutron time-of-flight facility nTOF at CERN

    CERN Document Server

    Abbondanno, U; Alvarez, F; Alvarez, H; Andriamonje, Samuel A; Andrzejewski, J; Badurek, G; Baumann, P; Becvar, F; Benlliure, J; Berthomieux, E; Betev, B; Calviño, F; Cano-Ott, D; Capote, R; Cennini, P; Chepel, V Yu; Chiaveri, Enrico; Colonna, N; Cortés, G; Cortina-Gil, D; Couture, A; Cox, J; Dababneh, S; David, S; Dolfini, R; Domingo-Pardo, C; Durán, I; Embid-Segura, M; Ferrant, L; Ferrari, A; Ferreira-Marques, R; Frais-Kölbl, H; Furman, W; Gonçalves, I; González-Romero, E M; Goverdovski, A A; Gramegna, F; Griesmayer, E; Gunsing, F; Haas, B; Haight, R; Heil, M; Herrera-Martínez, A; Isaev, S; Jericha, E; Kadi, Y; Käppeler, F K; Kerveno, M; Ketlerov, V; Köhler, P E; Konovalov, V; Krticka, M; Leeb, H; Lindote, A; Lopes, M I; Lozano, M; Lukic, S; Marganiec, J; Marrone, S; Martínez-Val, J M; Mastinu, P; Mengoni, A; Milazzo, P M; Molina-Coballes, A; Moreau, C; Mosconi, M; Neves, F; Oberhummer, Heinz; O'Brien, S; Pancin, J; Papaevangelou, T; Paradela, C; Pavlik, A; Pavlopoulos, P; Perlado, J M; Perrot, L; Peskov, Vladimir; Plag, R; Plompen, A; Plukis, A; Poch, A; Policarpo, Armando; Pretel, C; Quesada, J M; Rapp, W; Rauscher, T; Reifarth, R; Rosetti, M; Rubbia, Carlo; Rudolf, G; Rullhusen, P; Salgado, V; Schäfer, E; Soares, J C; Stephanq, C; Tagliente, G; Taín, J L; Tassan-Got, L; Tavora, L M N; Terlizzi, R; Vannini, G; Vaz, P; Ventura, A; Villamarín-Fernández, D; Vincente-Vincente, M; Vlachoudis, V; Voss, F; Wendler, H; Wiescher, M; Wisshak, K

    2005-01-01

    The n_TOF facility at CERN has been designed for the measurement of neutron capture, fission and (n, multiplied by n) cross-sections with high accuracy. This requires a flexible and - due to the high instantaneous neutron flux - almost dead time free data acquisition system. A scalable and versatile data solution has been designed based on 8-bit flash-ADCs with sampling rates up to 2 GHz and 8 Mbyte memory buffer. The software is written in C and C++ and is running on PCs equipped with RedHat Linux.

  5. Fission cross-section measurements on 233U and minor actinides at the CERN n-TOF facility

    International Nuclear Information System (INIS)

    Calviani, M.; Cennini, P.; Chiaveri, E.; Dahlfors, M.; Ferrari, A.; Herrera-Martinez, A.; Kadi, Y.; Sarchiapone, L.; Vlachoudis, V.; Colonna, N.; Terlizzi, R.; Abbondanno, U.; Marrone, S.; Belloni, F.; Fujii, K.; Moreau, C.; Aerts, G.; Andriamonje, S.; Berthoumieux, E.; Dridi, W.; Gunsing, F.; Pancin, J.; Perrot, L.; Plukis, A.; Alvarez, H.; Duran, I.; Paradela, C.; Alvarez-Velarde, F.; Cano-Ott, D.; Embid-Sesura, M.; Gonzalez-Romero, E.; Guerrero, C.; Martinez, T.; Vincente, M. C.; Andrzejewski, J.; Assimakopoulos, P.; Audouin, L.; David, S.; Ferrant, L.; Stephan, C.; Tassan-Got, L.; Badurek, G.; Jericha, E.; Leeb, H.; Oberhummer, H.; Pigni, M. T.; Baumann, P.; Kerveno, M.; Lukic, S.; Rudolf, G.; Becvar, F.; Calvino, F.; Capote, R.; Carrapico, C.; Chepel, V.; Ferreira-Marques, R.; Goncalves, I.; Lindote, A.; Lopes, I.; Neves, F.; Cortes, G.; Poch, A.; Pretel, C.; Couture, A.; Cox, J.; O'Brien, S.; Wiescher, M.; Dillmann, I.; Heil, M.; Kaeppeler, F.; Mosconi, M.; Plag, R.; Walter, S.; Wisshak, K.; Domingo-Pardo, C.; Eleftheriadis, C.; Furman, W.; Goverdovski, A.; Gramegna, F.; Mastinu, P.; Praena, J.; Haas, B.; Haight, R.; Igashira, M.; Karadimos, D.; Karamanis, D.; Ketlerov, V.; Koehler, P.; Konovalov, V.; Kossionides, E.; Krticka, M.; Lampoudis, C.; Lozano, M.; Marganiec, J.; Massimi, C.; Mengoni, A.; Milazzo, P. M.; Papachristodoulou, C.; Papadopoulos, C.; Patronis, N.; Pavlik, A.; Pavlopoulos, P.; Plompen, A.; Quesada, J.; Rauscher, T.; Reifarth, R.; Rubbia, C.; Rullhusen, P.; Salgado, J.; Santos, C.; Savvidis, I.; Tagliente, G.; Tain, J. L.; Tavora, L.; Vannini, G.; Vaz, P.; Ventura, A.; Villamarin, D.; Vlastou, R.; Voss, F.

    2010-01-01

    Neutron-induced fission cross-sections of minor actinides have been measured at the white neutron source n-TOF at CERN, Geneva. The studied isotopes include 233 U, interesting for Th/U based nuclear fuel cycles, 241, 243 Am and 245 Cm, relevant for transmutation and waste reduction studies in new generation fast reactors (Gen-IV) or Accelerator Driven Systems. The measurements take advantage of the unique features of the n-TOF facility, namely the wide energy range, the high instantaneous neutron flux and the low background. Results for the involved isotopes are reported from ∼30 meV to around 1 MeV neutron energy. The measurements have been performed with a dedicated Fission Ionization Chamber (FIC), relative to the standard cross-section of the 235 U fission reaction, measured simultaneously with the same detector. Results are here reported. (authors)

  6. High-precision measurement of the 238U(n,γ) cross-section at the n-TOF facility, CERN

    International Nuclear Information System (INIS)

    Wright, Tobias James; Billowes, Jon; Mingrone, Federica; Massimi, Cristian; Berthoumieux, Eric; Gunsing, Frank; Cano-Ott, Daniel; Mendoza, Emilio; Guerrero, Carlos; Schillebeeckx, P.

    2014-01-01

    A new experiment to measure the 238 U(n,γ) cross-section has been carried out at the CERN n-TOF facility within the ANDES project. Two complementary detection systems have been used: two low neutron sensitivity C6D6 detectors and the Total Absorption Calorimeter (TAC) comprising 40 BaF 2 scintillators. High quality data has been obtained up to 10 keV with the TAC and up to a higher neutron energy unresolved region with the C 6 D 6 . All the steps in the measurements and the subsequent data analysis are dealt with in depth, aiming for overall 2-3% accuracy per detection system. (authors)

  7. Astrophysics at nTOF facility

    International Nuclear Information System (INIS)

    Tagliente, G.; Colonna, N.; Maronne, S.; Terlizzi, R.; Abondanno, U.; Fujii, K.; Milazzo, P.M.; Moreau, C.; Belloni, F.; Aerts, G.; Berthoumieux, E.; Andriamonje, S.; Dridi, W.; Gunsing, F.; Pancin, J.; Perrot, L.; Alvarez, H.; Duran, I.; Paradela, C.; Alvarez-Velarde, F.; Cano-Ott, D.; Embid-Segura, M.; Guerrero, C.; Martinez, T.; Villamarin, D.; Vincente, M.C.; Gonzalez-Romero, E.; Andrzejewski, J.; Marganiec, J.; Assimakopoulos, P.; Karamanis, D.; Audouin, L.; Dillman, I.; Heil, M.; Kappeler, F.; Mosconi, M.; Plag, R.; Voss, F.; Walter, S.; Wissak, K.; Badurek, G.; Jericha, E.; Leeb, H.; Oberhummer, H.; Pigni, M.T.; Baumann, P.; David, S.; Kerveno, M.; Rudolf, G.; Lukic, S.; Becvar, F.; Krticka, M.; Bisterzo, S.; Ferrant, L.; Gallino, R.; Calvino, F.; Poch, A.; Pretel, C.; Calviani, M.; Gramegna, F.; Mastinu, P.; Capote, R.; Mengoni, A.; Capote, R.; Lozano, M.; Quesada, J.; Carrapico, C.; Salgado, J.; Santos, C.; Tavora, L.; Vaz, P.; Cennini, P.; Chiaveri, E.; Dahlfors, M.; Kadi, Y.; Sarchiapone, L.; Vlachoudis, V.; Wendler, H.; Chepel, V.; Ferreira-Marques, R.; Goncalves, I.; Lindote, A.; Lopes, I.; Neves, F.; Couture, A.; Cox, J.; O'Brien, S.; Wiescher, M.; Dominga-Pardo, C.; Tain, J.L.; Eleftheriadis, C.; Lamboudis, C.; Savvidis, I.; Stephan, C.; Tassan-Got, L.; Furman, W.; Haas, B.; Haight, R.; Reifarth, R.; Igashira, M.; Koehler, P.; Massimi, C.; Vannini, G.; Papadopoulos, C.; Pavlik, A.; Pavlopoulos, P.; Plomen, A.; Rullhusen, P.; Rauscher, T.; Rubbia, C.; Ventura, A.

    2009-01-01

    The neutron time of flight (n T OF) facility at CERN is a neutron spallation source, its white neutron energy spectrum ranges from thermal to several GeV, covering the full energy range of interest for nuclear astrophysics, in particular for measurements of the neutron capture cross-section required in s-process nucleosynthesis. This contribution gives an overview on the astrophysical program made at n T OF facility, the results and the implications will be considered.

  8. Happy birthday n_TOF!

    CERN Multimedia

    2010-01-01

    Picture CERN-GE-1011313_58 : From left to right: Enrique Gonzalez-Romero, Chairman of Collaboration Board, Enrico Chiaveri, Spokesperson of n_TOF Experiment, and Carlo Rubbia, the creator of the n_TOF experiment.

  9. n_TOF: a new experimental area under way

    CERN Multimedia

    Anaïs Schaeffer

    2013-01-01

    On Thursday 23 May, CERN celebrated the laying of the foundation stone of the new experimental area (EAR-2) of n_TOF – CERN’s neutron source facility*. Under a mild sun, Rolf Heuer, CERN Director-General, Enrico Chiaveri, spokesperson for the n_TOF collaboration, Frédérick Bordry, head of CERN’s Technology Department, and other important figures at CERN raised their glasses to the launch of this new scientific adventure.   Rolf Heuer, CERN Director-General, driving a backhoe at the EAR-2 foundation stone laying ceremony. “This new experimental area is very important as it shows the diversity of the science we are doing at CERN,” says Rolf Heuer. “One of the Laboratory’s goals is to build infrastructures and to do science that is unique, or at least world leading. And that is exactly what we are doing here.” The n_TOF collaboration is taking advantage of the long shutdown (LS1) for the const...

  10. Neutron resonance spectroscopy at n-TOF at CERN

    International Nuclear Information System (INIS)

    Gunsing, F.; Abbondanno, U.; Aerts, G.; Alvarez, H.; Alvarez-Velarde, F.; Andriamonje, S.; Andrzejewski, J.; Assimakopoulos, P.; Audouin, L.; Badurek, G.; Baumann, P.; Becvar, F.; Berthoumieux, E.; Calvino, F.; Calviani, M.; Cano-Ott, D.; Capote, R.; Carrapic, C.; Cennini, P.; Chepel, V.; Chiaveri, E.; Colonna, N.; Cortes, G.; Couture, A.; Cox, J.; Dahlfors, M.; David, S.; Dillmann, I.; Domingo-Pardo, C.; Dridi, W.; Duran, I.; Eleftheriadis, C.; Embid-Segura, M.; Ferrant, L.; Ferrari, A.; Ferreira-Marques, R.; Fujii, K.; Furman, W.; Goncalves, I.; Gonzalez-Romero, E.; Gramegna, F.; Guerrero, C.; Haas, B.; Haight, R.; Heil, M.; Herrera-Martinez, A.; Igashira, M.; Jericha, E.; Kappeler, F.; Kadi, Y.; Karadimos, D.; Karamanis, D.; Kerveno, M.; Koehler, P.; Kossionides, E.; Krticka, M.; Lampoudis, C.; Leeb, H.; Lindote, A.; Lopes, I.; Lozano, M.; Lukic, S.; Marganiec, J.; Marrone, S.; Martinez, T.; Massimi, C.; Mastinu, P.; Mengoni, A.; Milazzo, P.M.; Moreau, C.; Mosconi, M.; Neves, F.; Oberhummer, H.; O'Brien, S.; Pancin, J.; Papachristodoulou, C.; Papadopoulos, C.; Paradela, C.; Patronis, N.; Pavlik, A.; Pavlopoulos, P.; Perrot, L.; Pigni, M.T.; Plag, R.; Plompen, A.; Plukis, A.; Poch, A.; Praena, J.; Pretel, C.; Quesada, J.; Rauscher, T.; Reifarth, R.; Rubbia, C.; Rudolf, G.; Rullhusen, P.; Salgado, J.; Santos, C.; Sarchiapone, L.; Savvidis, I.; Stephan, C.; Tagliente, G.; Tain, J.L.; Tassan-Got, L.; Tavora, L.; Terlizzi, R.; Vannini, G.; Vaz, P.; Ventura, A.; Villamarin, D.; Vincente, M.C.; Vlachoudis, V.; Vlastou, R.; Voss, F.; Walter, S.; Wiescher, M.; Wisshak, K.

    2008-01-01

    Neutron resonance spectroscopy plays an important role in the investigation of neutron induced reaction cross sections and nuclear structure in the MeV excitation range. Neutron time-of-flight facilities are the most used installations to explore neutron resonances. In this paper we describe the basic features of neutron resonance spectroscopy together with recent results from the time-of-flight facility n-TOF at CERN. (authors)

  11. Neutron cross section measurements at n-TOF for ADS related studies

    Science.gov (United States)

    Mastinu, P. F.; Abbondanno, U.; Aerts, G.; Álvarez, H.; Alvarez-Velarde, F.; Andriamonje, S.; Andrzejewski, J.; Assimakopoulos, P.; Audouin, L.; Badurek, G.; Bustreo, N.; aumann, P.; vá, F. Be; Berthoumieux, E.; Calviño, F.; Cano-Ott, D.; Capote, R.; Carrillo de Albornoz, A.; Cennini, P.; Chepel, V.; Chiaveri, E.; Colonna, N.; Cortes, G.; Couture, A.; Cox, J.; Dahlfors, M.; David, S.; Dillmann, I.; Dolfini, R.; Domingo-Pardo, C.; Dridi, W.; Duran, I.; Eleftheriadis, C.; Embid-Segura, M.; Ferrant, L.; Ferrari, A.; Ferreira-Marques, R.; itzpatrick, L.; Frais-Kölbl, H.; Fujii, K.; Furman, W.; Guerrero, C.; Goncalves, I.; Gallino, R.; Gonzalez-Romero, E.; Goverdovski, A.; Gramegna, F.; Griesmayer, E.; Gunsing, F.; Haas, B.; Haight, R.; Heil, M.; Herrera-Martinez, A.; Igashira, M.; Isaev, S.; Jericha, E.; Kadi, Y.; Käppeler, F.; Karamanis, D.; Karadimos, D.; Kerveno, M.; Ketlerov, V.; Koehler, P.; Konovalov, V.; Kossionides, E.; Krti ka, M.; Lamboudis, C.; Leeb, H.; Lindote, A.; Lopes, I.; Lozano, M.; Lukic, S.; Marganiec, J.; Marques, L.; Marrone, S.; Massimi, C.; Mengoni, A.; Milazzo, P. M.; Moreau, C.; Mosconi, M.; Neves, F.; Oberhummer, H.; O'Brien, S.; Oshima, M.; Pancin, J.; Papachristodoulou, C.; Papadopoulos, C.; Paradela, C.; Patronis, N.; Pavlik, A.; Pavlopoulos, P.; Perrot, L.; Plag, R.; Plompen, A.; Plukis, A.; Poch, A.; Pretel, C.; Quesada, J.; Rauscher, T.; Reifarth, R.; Rosetti, M.; Rubbia, C.; Rudolf, G.; Rullhusen, P.; Salgado, J.; Sarchiapone, L.; Savvidis, I.; Stephan, C.; Tagliente, G.; Tain, J. L.; Tassan-Got, L.; Tavora, L.; Terlizzi, R.; Vannini, G.; Vaz, P.; Ventura, A.; Villamarin, D.; Vincente, M. C.; Vlachoudis, V.; Vlastou, R.; Voss, F.; Walter, S.; Wendler, H.; Wiescherand, M.; Wisshak, K.

    2006-05-01

    A neutron Time-of-Flight facility (n_TOF) is available at CERN since 2001. The innovative features of the neutron beam, in particular the high instantaneous flux, the wide energy range, the high resolution and the low background, make this facility unique for measurements of neutron induced reactions relevant to the field of Emerging Nuclear Technologies, as well as to Nuclear Astrophysics and Fundamental Nuclear Physics. The scientific motivations that have led to the construction of this new facility are here presented. The main characteristics of the n_TOF neutron beam are described, together with the features of the experimental apparata used for cross-section measurements. The main results of the first measurement campaigns are presented. Preliminary results of capture cross-section measurements of minor actinides, important to ADS project for nuclear waste transmutation, are finally discussed.

  12. Neutron cross section measurements at n-TOF for ADS related studies

    CERN Document Server

    Mastinu, P F; Aerts, G; Alvarez, H; Alvarez-Velarde, F; Andriamonje, Samuel A; Andrzejewski, J; Assimakopoulos, P A; Audouin, L; Badurek, G; Bustreo, N; Aumann, P; Beva, F; Berthoumieux, E; Calviño, F; Cano-Ott, D; Capote, R; Carillo de Albornoz, A; Cennini, P; Chepel, V; Chiaveri, Enrico; Colonna, N; Cortés, G; Couture, A; Cox, J; Dahlfors, M; David, S; Dillmann, I; Dolfini, R; Domingo-Pardo, C; Dridi, W; Durán, I; Eleftheriadis, C; Segura, M E; Ferrant, L; Ferrari, A; Ferreira-Marques, R; itzpatrick, L; Frais-Kölbl, H; Fujii, K; Furman, W; Guerrero, C; Gonçalves, I; Gallino, R; González-Romero, E M; Goverdovski, A; Gramegna, F; Griesmayer, E; Gunsing, F; Haas, B; Haight, R; Heil, M; Herrera-Martínez, A; Igashira, M; Isaev, S; Jericha, E; Kadi, Y; Käppeler, F K; Karamanis, D; Karadimos, D; Kerveno, M; Ketlerov, V; Köhler, P; Konovalov, V; Kossionides, E; Krticka, M; Lamboudis, C; Leeb, H; Lindote, A; Lopes, I; Lozano, M; Lukic, S; Marganiec, J; Marques, L; Marrone, S; Massimi, C; Mengoni, A; Milazzo, P M; Moreau, C; Mosconi, M; Neves, F; Oberhummer, Heinz; O'Brien, S; Oshima, M; Pancin, J; Papachristodoulou, C; Papadopoulos, C; Paradela, C; Patronis, N; Pavlik, A; Pavlopoulos, P; Perrot, L; Plag, R; Plompen, A; Plukis, A; Poch, A; Pretel, C; Quesada, J; Rauscher, T; Reifarth, R; Rosetti, M; Rubbia, Carlo; Rudolf, G; Rullhusen, P; Salgado, J; Sarchiapone, L; Savvidis, I; Stéphan, C; Tagliente, G; Taín, J L; Tassan-Got, L; Tavora, L; Terlizzi, R; Vannini, G; Vaz, P; Ventura, A; Villamarín, D; Vincente, M C; Vlachoudis, V; Vlastou, R; Voss, F; Walter, S; Wendler, H; Wiescherand, M; Wisshak, K

    2006-01-01

    A neutron Time-of-Flight facility (n_TOF) is available at CERN since 2001. The innovative features of the neutron beam, in particular the high instantaneous flux, the wide energy range, the high resolution and the low background, make this facility unique for measurements of neutron induced reactions relevant to the field of Emerging Nuclear Technologies, as well as to Nuclear Astrophysics and Fundamental Nuclear Physics. The scientific motivations that have led to the construction of this new facility are here presented. The main characteristics of the n_TOF neutron beam are described, together with the features of the experimental apparata used for cross-section measurements. The main results of the first measurement campaigns are presented. Preliminary results of capture cross-section measurements of minor actinides, important to ADS project for nuclear waste transmutation, are finally discussed.

  13. Measurement of the 241Am and the 243Am Neutron Capture Cross Sections at the n_TOF Facility at CERN

    CERN Document Server

    Mendoza, E; Guerrero, C; Altstadt, S; Andrzejewski, J; Audouin, L; Barbagallo, M; Bécares, V; Bečvář, F; Belloni, F; Berthoumieux, E; Billowes, J; Boccone, V; Bosnar, D; Brugger, M; Calviani, M; Calviño, F; Carrapiço, C; Cerutti, F; Chiaveri, E; Chin, M; Colonna, N; Cortés, G; Cortés-Giraldo, M A; Diakaki, M; Domingo-Pardo, C; Duran, I; Dressler, R; Dzysiuk, N; Eleftheriadis, C; Ferrari, A; Fraval, K; Ganesan, S; García, A R; Giubrone, G; Gómez-Hornillos, M B; Gonçalves, I F; González-Romero, E; Griesmayer, E; Gunsing, F; Gurusamy, P; Jenkins, D G; Jericha, E; Kadi, Y; Käppeler, F; Karadimos, D; Kivel, N; Koehler, P; Kokkoris, M; Korschinek, G; Krtička, M; Kroll, J; Langer, C; Lederer, C; Leeb, H; Leong, L S; Losito, R; Manousos, A; Marganiec, J; Martínez, T; Mastinu, P F; Mastromarco, M; Massimi, C; Meaze, M; Mengoni, A; Milazzo, P M; Mingrone, F; Mirea, M; Mondelaers, W; Paradela, C; Pavlik, A; Perkowski, J; Pignatari, M; Plompen, A; Praena, J; Quesada, J M; Rauscher, T; Reifarth, R; Riego, A; Roman, F; Rubbia, C; Sarmento, R; Schillebeeckx, P; Schmidt, S; Schumann, D; Tagliente, G; Tain, J L; Tarrío, D; Tassan-Got, L; Tsinganis, A; Valenta, S; Vannini, G; Variale, V; Vaz, P; Ventura, A; Versaci, R; Vermeulen, M J; Vlachoudis, V; Vlastou, R; Wallner, A; Ware, T; Weigand, M; Weiß, C; Wright, T J; Žugec, P

    2014-01-01

    The capture cross sections of Am-241 and Am-243 were measured at the n\\_TOF facility at CERN in the epithermal energy range with a BaF2 Total Absorption Calorimeter. A preliminary analysis of the Am-241 and a complete analysis of the Am-243 measurement, including the data reduction and the resonance analysis, have been performed.

  14. Study of the background in the measuring station at the n_TOF facility at CERN: sources and solutions

    CERN Document Server

    Zanini, L; Aerts, G; Andriamonje, Samuel A; Andrzejewski, J; Angelopoulous, A; Assimakopoulos, Panayiotis; Bacri, C-O; Badurek, G; Berthoumieux, E; Baumann, P; Beer, H; Benlliure, J; Berthier, B; Bondarenko, I; Borcea, C; Bos, A J J; Boscolo-Marchi, E; Bustreo, N; Calviño, F; Cano-Ott, D; Capote, R; Carlson, P; Charpak, Georges; Chauvin, N; Cennini, P; Chepel, V; Colonna, N; Cortés, G; Cortina-Gil, D; Corvi, F; Cusmano, A; Dababneh, S; Dahlfors, M; Damianoglou, D; David, S; Dimovasili, E; Domingo, C; Doroshenko, A; Duran-Escribano, I; Eleftheriadis, C; Embid, M; Ferrant, L; Ferrari, A; Ferreira-Marques, R; Frais-Kölbl, H; Furman, W; Fursov, B; Garzón, J A; Giomataris, Ioanis; Gledenov, Y; Gonzalez-Romero, E; Goverdovski, A; Gramegna, F; Griesmayer, E; Gunsing, F; Haefner, P; Haight, R; Heil, M; Herrera-martinez, A; Hollander, P; Ioannou, P; Isaev, S; Jericha, E; Kadi, Y; Kappeler, F; Karadimos, D; Karamanis, D; Kayukova, A; Kazakov, L; Kelic, A; Ketlerov, V; Kitis, G; Köhler, P E; Kopach, Y; Kossionides, E; Kroshkina, I; Lacoste, V; Lamboudis, C; Leeb, H; Leprêtre, A; Lopes, M; Lozano, M; Marrone, S; Martínez-Val, J M; Mastinu, P; Mengoni, A; Meunier, R; Mezentsev, A J; Milazzo, P; Minguez, E; Mitrofanov, V; Moreau, C; Müller, A; Nicolis, N; Nikolenkov, V; Oberhummer, Heinz; Pakou, A; Pancin, J; Papadopoulous, K; Papaevangelou, T; Paradela, C; Paradelis, T; Pavlik, A; Pavlopoulos, P; Perrez-Parra, A; Perriale, L; Perlado, J M; Peskov, Vladimir; Piksaikin, V; Plag, R; Plompen, A; Plukis, A; Poch, A; Policarpo, Armando; Popov, A; Popov, Y P; Pretel, C; Quesada, J M; Radermacher, E; Rapp, W; Rauscher, T; Reifarth, R; Rejmund, F; Rubbia, Carlo; Rudolf, G; Rullhusen, P; Sakelliou, L; Saldaña, F; Samylin, B; Savvidis, I; Savvidis, S; Sedyshev, P; Stéphan, C; Szalanski, P; Tagliente, G; Taín, J L; Tapia, C; Tassan-Got, L; Terchychnyi, R; Tsabaris, C; Tsangas, N; van Eijk, C W E; Vannini, G; Ventura, A; Villamarin, A; Vlachoudis, V; Vlastou, R; Voinov, A; Voss, F; Wendler, H; Wiescher, M; Wisshak, K; Zanini, L; Zeinalov, S; Zhuravlev, B; CERN. Geneva. SPS and LHC Division

    2001-01-01

    A background roughly two orders of magnitude higher than tolerable was found in the n_TOF facility at CERN during the first measurements [1]. This note describes a series of additional measurements performed in the n_TOF experimental area to study the origin and the characteristics of the background. The program of these measurements was determined taking into account the results from the simulations carried out by the EET group [2]. A first phase of measurements confirmed what was expected from the simulations, namely that the dominant source of background was due to neutrons generated by negative muon capture. Actions to reduce the background were taken according to the results from both measurements and simulations. An iron shielding wall 3.2 m thick was then placed in between the sweeping magnet and the second collimator, with the purpose of stopping most of the muons. In a second phase of measurements, results showed that the additional shielding reduced the main component of the background by about a fa...

  15. Neutron cross-sections for next generation reactors: New data from n_TOF

    CERN Document Server

    Colonna, N; Eleftheriadis, C; Leeb, H; Tain, J L; Calvino, F; Herrera-Martinez, A; Savvidis, I; Vlachoudis, V; Haas, B; Abbondanno, U; Vannini, G; Konovalov, V; Marques, L; Wiescher, M; de Albornoz, A Carrillo; Audouin, L; Mengoni, A; Quesada, J; Becvar, F; Plag, R; Cennini, P; Mosconi, M; Duran, I; Rauscher, T; Ketlerov, V; Couture, A; Capote, R; Sarchiapone, L; Pigni, M T; Vlastou, R; Domingo-Pardo, C; Pavlopoulos, P; Karamanis, D; Krticka, M; Jericha, E; Ferrari, A; Martinez, T; Oberhummer, H; Karadimos, D; Plompen, A; Isaev, S; Terlizzi, R; Kaeppeler, F; Cortes, G; Cox, J; Voss, F; Pretel, C; Berthoumieux, E; Dolfini, R; Vaz, P; Griesmayer, E; Heil, M; Lopes, I; Lampoudis, C; Walter, S; Calviani, M; Gonzalez-Romero, E; Stephan, C; Igashira, M; Papachristodoulou, C; Aerts, G; Tavora, L; Wendler, H; Milazzo, P M; Rudolf, G; Andrzejewski, J; Villamarin, D; Ferreira-Marques, R; O'Brien, S; Gunsing, F; Reifarth, R; Perrot, L; Lindote, A; Neves, F; Poch, A; Gramegna, F; Kerveno, M; Rubbia, C; Koehler, P; Dahlfors, M; Wisshak, K; Fujii, K; Salgado, J; Dridi, W; Ventura, A; Andriamonje, S; Dillman, I; Assimakopoulos, P; Ferrant, L; Lozano, M; Patronis, N; Chiaveri, E; Guerrero, C; Kadi, Y; Baumann, P; Moreau, C; Oshima, M; Rullhusen, P; Furman, W; David, S; Marrone, S; Paradela, C; Vicente, M C; Tassan-Got, L; Cano-Ott, D; Alvarez-Velarde, F; Massimi, C; Mastinu, P; Pancin, J; Papadopoulos, C; Tagliente, G; Alvarez, H; Haight, R; Goverdovski, A; Chepel, V; Rosetti, M; Kossionides, E; Badurek, G; Marganiec, J; Lukic, S; Frais-Koelbl, H; Pavlik, A; Goncalves, I

    2010-01-01

    In 2002, an innovative neutron time-of-flight facility started operation at CERN: n\\_TOF. The main characteristics that make the new facility unique are the high instantaneous neutron flux, high resolution and wide energy range. Combined with state-of-the-art detectors and data acquisition system, these features have allowed to collect high accuracy neutron cross-section data on a variety of isotopes, many of which radioactive, of interest for Nuclear Astrophysics and for applications to advanced reactor technologies. A review of the most important results on capture and fission reactions obtained so far at n\\_TOF is presented, together with plans for new measurements related to nuclear industry. (C) 2010 Elsevier Ltd. All rights reserved.

  16. Commissioning of n_TOF EAR2

    CERN Multimedia

    The construction of the second beam line and experiment area (EAR2) of the n_TOF facility is currently ongoing and scheduled to be completed by July 2014. An extensive series of measurements is planned in order to determine the beam characteristics like the neutron flux, the spatial beam profile and the resolution function, as well as the response of several detectors considered for use in future measurements at EAR2. A rigorous study of backgrounds will be undertaken in various conditions.

  17. Finding an analytic description of the resolution function for n_TOF-EAR2 at CERN

    CERN Document Server

    Eriksson, John Benjamin

    2017-01-01

    At CERN's neutron time-of-flight facility n_TOF a high intensity pulsed neutron source is used to measure energy-dependent neutron-induced reaction cross sections of isotopes relevant to various fields of research such as nuclear astrophysics, -technology or -medicine. Neutron kinetic energies are determined using the time-of-flight (ToF) technique. A correct ToF to energy conversion is essential and is influenced by many factors, one of which is the so-called resolution function (RF). The RF is a characteristic unique to each experimental facility and can only be determined through simulations using Monte Carlo codes. The goal of this project is to find an analytic description of the RF for n_TOF-EAR2. Two functions for two different energy ranges were found, each a combination of linear, polynomial and exponential functions. Furthermore, the energy dependence of the function's parameters was investigated.

  18. Experimental neutron capture data of 58Ni from the CERN n_TOF facility

    Directory of Open Access Journals (Sweden)

    Žugec P.

    2015-01-01

    Full Text Available The neutron capture cross section of 58Ni was measured at the neutron time of flight facility n_TOF at CERN, from 27 meV to 400 keV neutron energy. Special care has been taken to identify all the possible sources of background, with the so-called neutron background obtained for the first time using high-precision GEANT4 simulations. The energy range up to 122 keV was treated as the resolved resonance region, where 51 resonances were identified and analyzed by a multilevel R-matrix code SAMMY. Above 122 keV the code SESH was used in analyzing the unresolved resonance region of the capture yield. Maxwellian averaged cross sections were calculated in the temperature range of kT = 5 – 100 keV, and their astrophysical implications were investigated.

  19. Measurement and analysis of the 241Am neutron capture cross section at the n_TOF facility at CERN

    Science.gov (United States)

    Mendoza, E.; Cano-Ott, D.; Altstadt, S.; Andriamonje, S.; Andrzejewski, J.; Audouin, L.; Balibrea, J.; Bécares, V.; Barbagallo, M.; Bečvář, F.; Belloni, F.; Berthier, B.; Berthoumieux, E.; Billowes, J.; Bosnar, D.; Brugger, M.; Calviño, F.; Calviani, M.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Colonna, N.; Cortés, G.; Cortés-Giraldo, M. A.; Diakaki, M.; Dillmann, I.; Domingo-Pardo, C.; Durán, I.; Dzysiuk, N.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Furman, V.; Gómez-Hornillos, M. B.; Ganesan, S.; García, A. R.; Giubrone, G.; Gonçalves, I. F.; González, E.; Goverdovski, A.; Gramegna, F.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Gurusamy, P.; Heftrich, T.; Heinitz, S.; Hernández-Prieto, A.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Karadimos, D.; Katabuchi, T.; Ketlerov, V.; Khryachkov, V.; Koehler, P.; Kokkoris, M.; Kroll, J.; Krtička, M.; Lampoudis, C.; Langer, C.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Leong, L. S.; Lerendegui-Marco, J.; Licata, M.; López, D.; Losito, R.; Manousos, A.; Marganiec, J.; Martínez, T.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Mondelaers, W.; Paradela, C.; Pavlik, A.; Perkowski, J.; Plompen, A. J. M.; Praena, J.; Quesada, J. M.; Rauscher, T.; Reifarth, R.; Riego-Perez, A.; Robles, M.; Roman, F.; Rubbia, C.; Ryan, J. A.; Sabaté-Gilarte, M.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Sedyshev, P.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vermeulen, M. J.; Versaci, R.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiss, C.; Wright, T.; Žugec, P.; n TOF Collaboration

    2018-05-01

    The 241Am(n ,γ ) cross section has been measured at the n_TOF facility at CERN with the n_TOF BaF2 Total Absorption Calorimeter in the energy range between 0.2 eV and 10 keV. Our results are analyzed as resolved resonances up to 700 eV, allowing a more detailed description of the cross section than in the current evaluations, which contain resolved resonances only up to 150-160 eV. The cross section in the unresolved resonance region is perfectly consistent with the predictions based on the average resonance parameters deduced from the resolved resonances, thus obtaining a consistent description of the cross section in the full neutron energy range under study. Below 20 eV, our results are in reasonable agreement with JEFF-3.2 as well as with the most recent direct measurements of the resonance integral, and differ up to 20-30% with other experimental data. Between 20 eV and 1 keV, the disagreement with other experimental data and evaluations gradually decreases, in general, with the neutron energy. Above 1 keV, we find compatible results with previously existing values.

  20. Neutron Time-Of-Flight (n_TOF) experiment

    CERN Multimedia

    Brugger, M; Kaeppeler, F K; Jericha, E; Cortes rossell, G P; Riego perez, A; Baccomi, R; Laurent, B G; Griesmayer, E; Leeb, H; Dressler, M; Cano ott, D; Variale, V; Ventura, A; Carrillo de albornoz trillo, A; Andrzejewski, J J; Pavlik, A F; Kadi, Y; Zanni vlastou, R; Krticka, M; Kokkoris, M; Praena rodriguez, A J; Cortes giraldo, M A; Perkowski, J; Losito, R; Audouin, L; Weiss, C; Tagliente, G; Wallner, A; Woods, P J; Mengoni, A; Guerrero sanchez, C G; Tain enriquez, J L; Vlachoudis, V; Calviani, M; Junghans, A R; Reifarth, R; Mendoza cembranos, E; Quesada molina, J M; Babiano suarez, V; Schumann, M D; Tsinganis, A; Rauscher, T; Calvino tavares, F; Mingrone, F; Gonzalez romero, E M; Colonna, N; Negret, A L; Chiaveri, E; Milazzo, P M; De almeida carrapico, C A; Castelluccio, D M

    The neutron time-of-flight facility n_TOF at CERN, Switzerland, operational since 2001, delivers neutrons using the Proton Synchrotron (PS) 20 GeV/c proton beam impinging on a lead spallation target. The facility combines a very high instantaneous neutron flux, an excellent time of flight resolution due to the distance between the experimental area and the production target (185 meters), a low intrinsic background and a wide range of neutron energies, from thermal to GeV neutrons. These characteristics provide a unique possibility to perform neutron-induced capture and fission cross-section measurements for applications in nuclear astrophysics and in nuclear reactor technology.

  1. High-accuracy determination of the neutron flux at n{sub T}OF

    Energy Technology Data Exchange (ETDEWEB)

    Barbagallo, M.; Colonna, N.; Mastromarco, M.; Meaze, M.; Tagliente, G.; Variale, V. [Sezione di Bari, INFN, Bari (Italy); Guerrero, C.; Andriamonje, S.; Boccone, V.; Brugger, M.; Calviani, M.; Cerutti, F.; Chin, M.; Ferrari, A.; Kadi, Y.; Losito, R.; Versaci, R.; Vlachoudis, V. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Tsinganis, A. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); National Technical University of Athens (NTUA), Athens (Greece); Tarrio, D.; Duran, I.; Leal-Cidoncha, E.; Paradela, C. [Universidade de Santiago de Compostela, Santiago (Spain); Altstadt, S.; Goebel, K.; Langer, C.; Reifarth, R.; Schmidt, S.; Weigand, M. [Johann-Wolfgang-Goethe Universitaet, Frankfurt (Germany); Andrzejewski, J.; Marganiec, J.; Perkowski, J. [Uniwersytet Lodzki, Lodz (Poland); Audouin, L.; Leong, L.S.; Tassan-Got, L. [Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay (France); Becares, V.; Cano-Ott, D.; Garcia, A.R.; Gonzalez-Romero, E.; Martinez, T.; Mendoza, E. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain); Becvar, F.; Krticka, M.; Kroll, J.; Valenta, S. [Charles University, Prague (Czech Republic); Belloni, F.; Fraval, K.; Gunsing, F.; Lampoudis, C.; Papaevangelou, T. [Commissariata l' Energie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Berthoumieux, E.; Chiaveri, E. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Commissariata l' Energie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Billowes, J.; Ware, T.; Wright, T. [University of Manchester, Manchester (United Kingdom); Bosnar, D.; Zugec, P. [University of Zagreb, Department of Physics, Faculty of Science, Zagreb (Croatia); Calvino, F.; Cortes, G.; Gomez-Hornillos, M.B.; Riego, A. [Universitat Politecnica de Catalunya, Barcelona (Spain); Carrapico, C.; Goncalves, I.F.; Sarmento, R.; Vaz, P. [Universidade Tecnica de Lisboa, Instituto Tecnologico e Nuclear, Instituto Superior Tecnico, Lisboa (Portugal); Cortes-Giraldo, M.A.; Praena, J.; Quesada, J.M.; Sabate-Gilarte, M. [Universidad de Sevilla, Sevilla (Spain); Diakaki, M.; Karadimos, D.; Kokkoris, M.; Vlastou, R. [National Technical University of Athens (NTUA), Athens (Greece); Domingo-Pardo, C.; Giubrone, G.; Tain, J.L. [CSIC-Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (Spain); Dressler, R.; Kivel, N.; Schumann, D.; Steinegger, P. [Paul Scherrer Institut, Villigen PSI (Switzerland); Dzysiuk, N.; Mastinu, P.F. [Laboratori Nazionali di Legnaro, INFN, Rome (Italy); Eleftheriadis, C.; Manousos, A. [Aristotle University of Thessaloniki, Thessaloniki (Greece); Ganesan, S.; Gurusamy, P.; Saxena, A. [Bhabha Atomic Research Centre (BARC), Mumbai (IN); Griesmayer, E.; Jericha, E.; Leeb, H. [Technische Universitaet Wien, Atominstitut, Wien (AT); Hernandez-Prieto, A. [European Organization for Nuclear Research (CERN), Geneva (CH); Universitat Politecnica de Catalunya, Barcelona (ES); Jenkins, D.G.; Vermeulen, M.J. [University of York, Heslington, York (GB); Kaeppeler, F. [Institut fuer Kernphysik, Karlsruhe Institute of Technology, Campus Nord, Karlsruhe (DE); Koehler, P. [Oak Ridge National Laboratory (ORNL), Oak Ridge (US); Lederer, C. [Johann-Wolfgang-Goethe Universitaet, Frankfurt (DE); University of Vienna, Faculty of Physics, Vienna (AT); Massimi, C.; Mingrone, F.; Vannini, G. [Universita di Bologna (IT); INFN, Sezione di Bologna, Dipartimento di Fisica, Bologna (IT); Mengoni, A.; Ventura, A. [Agenzia nazionale per le nuove tecnologie, l' energia e lo sviluppo economico sostenibile (ENEA), Bologna (IT); Milazzo, P.M. [Sezione di Trieste, INFN, Trieste (IT); Mirea, M. [Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele (RO); Mondalaers, W.; Plompen, A.; Schillebeeckx, P. [Institute for Reference Materials and Measurements, European Commission JRC, Geel (BE); Pavlik, A.; Wallner, A. [University of Vienna, Faculty of Physics, Vienna (AT); Rauscher, T. [University of Basel, Department of Physics and Astronomy, Basel (CH); Roman, F. [European Organization for Nuclear Research (CERN), Geneva (CH); Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele (RO); Rubbia, C. [European Organization for Nuclear Research (CERN), Geneva (CH); Laboratori Nazionali del Gran Sasso dell' INFN, Assergi (AQ) (IT); Weiss, C. [European Organization for Nuclear Research (CERN), Geneva (CH); Johann-Wolfgang-Goethe Universitaet, Frankfurt (DE)

    2013-12-15

    The neutron flux of the n{sub T}OF facility at CERN was measured, after installation of the new spallation target, with four different systems based on three neutron-converting reactions, which represent accepted cross sections standards in different energy regions. A careful comparison and combination of the different measurements allowed us to reach an unprecedented accuracy on the energy dependence of the neutron flux in the very wide range (thermal to 1 GeV) that characterizes the n{sub T}OF neutron beam. This is a pre-requisite for the high accuracy of cross section measurements at n{sub T}OF. An unexpected anomaly in the neutron-induced fission cross section of {sup 235}U is observed in the energy region between 10 and 30keV, hinting at a possible overestimation of this important cross section, well above currently assigned uncertainties. (orig.)

  2. Measurement and analysis of the $^{241}$Am(n,$\\gamma$) cross section at the CERN n_TOF facility.

    CERN Document Server

    Fraval, Kevin

    In the context of the current nuclear technology, the radiotoxicity of the spent fuel of a typical PWR reactor is dominated by minor actinides for times greater than 104 years. In particular, 241Am and its 432 years half-life is responsible for about half of the minor actinide content of a PWR spent fuel. This thesis work consisted in measuring and analysing the 241Am(n, ) cross section at the CERN n TOF facility. After selecting exclusively the events obtained with lead shielding in front of the C6D6 detectors, the amplitude-energy calibration has to be adjusted with time, by using a photon coming from the 27Al(,,p)30Si reaction. Histogram extraction included applying a weighting function (obtained by MCNP simulation), a dead time correction, and a normalization to the compound nucleus excitation energy. The background corrected spectra were normalized relatively to the 4.9 eV resonance on 197Au. Finally, the resonance analysis was performed using the SAMMY code. The extracted thermal value is 678±68 barns,...

  3. Experimental neutron capture data of $^{58}$Ni from the CERN n_TOF facility

    CERN Document Server

    Žugec, P.; Colonna, N.; Bosnar, D.; Altstadt, S.; Andrzejewski, J.; Audouin, L.; Bécares, V.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Billowes, J.; Boccone, V.; Brugger, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Cortés, G.; Cortés-Giraldo, M.A.; Diakaki, M.; Domingo-Pardo, C.; Duran, I.; Dzysiuk, N.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Ganesan, S.; García, A.R.; Giubrone, G.; Gómez-Hornillos, M.B.; Gonçalves, I.F.; González-Romero, E.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Gurusamy, P.; Jenkins, D.G.; Jericha, E.; Kadi, Y.; Käppeler, F.; Karadimos, D.; Koehler, P.; Kokkoris, M.; Krtička, M.; Kroll, J.; Langer, C.; Lederer, C.; Leeb, H.; Leong, L.S.; Losito, R.; Manousos, A.; Marganiec, J.; Martìnez, T.; Massimi, C.; Mastinu, P.F.; Mastromarco, M.; Meaze, M.; Mendoza, E.; Mengoni, A.; Milazzo, P.M.; Mingrone, F.; Mirea, M.; Mondalaers, W.; Paradela, C.; Pavlik, A.; Perkowski, J.; Pignatari, M.; Plompen, A.; Praena, J.; Quesada, J.M.; Rauscher, T.; Reifarth, R.; Riego, A.; Roman, F.; Rubbia, C.; Sarmento, R.; Schillebeeckx, P.; Schmidt, S.; Tagliente, G.; Tain, J.L.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Versaci, R.; Vermeulen, M.J.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiß, C.; Wright, T.

    2013-01-01

    The $^{58}$Ni $(n,\\gamma)$ cross section has been measured at the neutron time of flight facility n_TOF at CERN, in the energy range from 27 meV up to 400 keV. In total, 51 resonances have been analyzed up to 122 keV. Maxwellian averaged cross sections (MACS) have been calculated for stellar temperatures of kT$=$5-100 keV with uncertainties of less than 6%, showing fair agreement with recent experimental and evaluated data up to kT = 50 keV. The MACS extracted in the present work at 30 keV is 34.2$\\pm$0.6$_\\mathrm{stat}\\pm$1.8$_\\mathrm{sys}$ mb, in agreement with latest results and evaluations, but 12% lower relative to the recent KADoNIS compilation of astrophysical cross sections. When included in models of the s-process nucleosynthesis in massive stars, this change results in a 60% increase of the abundance of $^{58}$Ni, with a negligible propagation on heavier isotopes. The reason is that, using both the old or the new MACS, 58Ni is efficiently depleted by neutron captures.

  4. The new vertical neutron beam line at the CERN n-TOF facility design and outlook on the performance

    Energy Technology Data Exchange (ETDEWEB)

    Weiß, C., E-mail: christina.weiss@cern.ch [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Chiaveri, E.; Girod, S.; Vlachoudis, V.; Aberle, O. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Barros, S. [Instituto Tecnológico e Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, Lisboa (Portugal); Bergström, I. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Berthoumieux, E. [Commissariat à l’Énergie Atomique (CEA) Saclay – Irfu, Gif-sur-Yvette (France); Calviani, M. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Guerrero, C.; Sabaté-Gilarte, M. [Universidad de Sevilla (Spain); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Tsinganis, A. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); National Technical University of Athens (NTUA) (Greece); Andrzejewski, J. [Uniwersytet Łódzki, Lodz (Poland); Audouin, L. [Centre National de la Recherche Scientifique/IN2P3 – IPN, Orsay (France); Bacak, M. [Atominstitut, Technische Universität Wien (Austria); Balibrea-Correa, J. [Centro de Investigaciones Energeticas Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain); Barbagallo, M. [Istituto Nazionale di Fisica Nucleare, Bari (Italy); Bécares, V. [Centro de Investigaciones Energeticas Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain); and others

    2015-11-01

    At the neutron time-of-flight facility n-TOF at CERN a new vertical beam line was constructed in 2014, in order to extend the experimental possibilities at this facility to an even wider range of challenging cross-section measurements of interest in astrophysics, nuclear technology and medical physics. The design of the beam line and the experimental hall was based on FLUKA Monte Carlo simulations, aiming at maximizing the neutron flux, reducing the beam halo and minimizing the background from neutrons interacting with the collimator or back-scattered in the beam dump. The present paper gives an overview on the design of the beam line and the relevant elements and provides an outlook on the expected performance regarding the neutron beam intensity, shape and energy resolution, as well as the neutron and photon backgrounds.

  5. n_TOF New target commissioning and beam characterization

    CERN Multimedia

    Igashira, M

    A full characterization of the neutron beam and experimental conditions for measurement with the new spallation target installed at the n_TOF facility is proposed. In a first step, the behavior the target assembly under the proton beam irradiation will be investigated, in order to complete the target commissioning. Subsequently the neutron beam parameters required to analyze the physics measurements, i.e. neutron fluence, beam profile, energy resolution function and beam related backgrounds as a function of the neutron energy, will be determined.

  6. 7Be(n,α and 7Be(n,p cross-section measurement for the cosmological lithium problem at the n_TOF facility at CERN

    Directory of Open Access Journals (Sweden)

    Barbagallo M.

    2017-01-01

    Full Text Available The Cosmological Lithium Problem refers to the large discrepancy between the abundance of primordial 7Li predicted by the standard theory of Big Bang Nucleosynthesis and the value inferred from the so-called “Spite plateau” in halo stars. A possible explanation for this longstanding puzzle in Nuclear Astrophysics is related to the incorrect estimation of the destruction rate of 7Be, which is responsible for the production of 95% of primordial Lithium. While charged-particle induced reactions have mostly been ruled out, data on the 7Be(n,α and 7Be(n,p reactions are scarce or completely missing, so that a large uncertainty still affects the abundance of 7Li predicted by the standard theory of Big Bang Nucleosynthesis. Both reactions have been measured at the n_TOF facility at CERN, providing for the first time data in a wide neutron energy range.

  7. 7Be(n,α) and 7Be(n,p) cross-section measurement for the cosmological lithium problem at the n_TOF facility at CERN

    Science.gov (United States)

    Barbagallo, M.; Colonna, N.; Aberle, O.; Andrzejewski, J.; Audouin, L.; Bécares, V.; Bacak, M.; Balibrea, J.; Barros, S.; Bečvář, F.; Beinrucker, C.; Berthoumieux, E.; Billowes, J.; Bosnar, D.; Brugger, M.; Caamaño, M.; Calviño, F.; Calviani, M.; Cano-Ott, D.; Cardella, R.; Casanovas, A.; Castelluccio, D. M.; Cerutti, F.; Chen, Y. H.; Chiaveri, E.; Cortés, G.; Cortés-Giraldo, M. A.; Cosentino, L.; Damone, L. A.; Diakaki, M.; Domingo-Pardo, C.; Dressler, R.; Dupont, E.; Durán, I.; Fernández-Domínguez, B.; Ferrari, A.; Ferreira, P.; Finocchiaro, P.; Furman, V.; Göbel, K.; García, A. R.; Gawlik, A.; Glodariu, T.; Gonçalves, I. F.; González, E.; Goverdovski, A.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Harada, H.; Heftrich, T.; Heinitz, S.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Katabuchi, T.; Kavrigin, P.; Ketlerov, V.; Khryachkov, V.; Kimura, A.; Kivel, N.; Kokkoris, M.; Krtička, M.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Lerendegui-Marco, J.; Meo, S. Lo; Lonsdale, S. J.; Losito, R.; Macina, D.; Marganiec, J.; Martínez, T.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Matteucci, F.; Maugeri, E. A.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Montesano, S.; Musumarra, A.; Nolte, R.; Oprea, A.; Patronis, N.; Pavlik, A.; Perkowski, J.; Porras, J. I.; Praena, J.; Quesada, J. M.; Rajeev, K.; Rauscher, T.; Reifarth, R.; Riego-Perez, A.; Rout, P. C.; Rubbia, C.; Ryan, J. A.; Sabaté-Gilarte, M.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Sedyshev, P.; Smith, A. G.; Stamatopoulos, A.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Warren, S.; Weigand, M.; Weiss, C.; Wolf, C.; Woods, P. J.; Wright, T.; Žugec, P.

    2017-09-01

    The Cosmological Lithium Problem refers to the large discrepancy between the abundance of primordial 7Li predicted by the standard theory of Big Bang Nucleosynthesis and the value inferred from the so-called "Spite plateau" in halo stars. A possible explanation for this longstanding puzzle in Nuclear Astrophysics is related to the incorrect estimation of the destruction rate of 7Be, which is responsible for the production of 95% of primordial Lithium. While charged-particle induced reactions have mostly been ruled out, data on the 7Be(n,α) and 7Be(n,p) reactions are scarce or completely missing, so that a large uncertainty still affects the abundance of 7Li predicted by the standard theory of Big Bang Nucleosynthesis. Both reactions have been measured at the n_TOF facility at CERN, providing for the first time data in a wide neutron energy range.

  8. Development of the STEFF detector for the neutron Time Of Flight facility (n_TOF), CERN

    CERN Document Server

    AUTHOR|(CDS)2092031

    Signicant work has been performed on the development of STEFF (SpecTrometer for Exotic Fission Fragments), a 2E2V (2-Energy 2-Velocity) spectrometer built by the University of Manchester Fission Group. The majority of this work was in the development of the time-of-flight systems, in particular the stop detector; with the main goals of improving the timing resolution and the detection eciency of the ssion fragments. Further development of the STEFF spectrometer was done to enable 2E2V measurements of the $^{235}$U(n,f) reaction with coincident measurements using a white neutron spectra of energies ranging from 10 meV to 200 MeV provided by the n_TOF (neutron Time Of Flight) facility, CERN. The STEFF spectrometer was successfully operated twice on the Experimental Area-2 high flux pulsed neutron beam line resulting in 2E2V measurements for ssion events with neutron energies ranging from 20 meV to 10 MeV. The first experiment received 1.36 X 10$^{18}$ POT (Protons On Target) with stable conditions and the seco...

  9. Measurement of the 241Am neutron capture cross section at the n_TOF facility at CERN

    Directory of Open Access Journals (Sweden)

    Mendoza E.

    2017-01-01

    Full Text Available New neutron cross section measurements of minor actinides have been performed recently in order to reduce the uncertainties in the evaluated data, which is important for the design of advanced nuclear reactors and, in particular, for determining their performance in the transmutation of nuclear waste. We have measured the 241Am(n,γ cross section at the n_TOF facility between 0.2 eV and 10 keV with a BaF2 Total Absorption Calorimeter, and the analysis of the measurement has been recently concluded. Our results are in reasonable agreement below 20 eV with the ones published by C. Lampoudis et al. in 2013, who reported a 22% larger capture cross section up to 110 eV compared to experimental and evaluated data published before. Our results also indicate that the 241Am(n,γ cross section is underestimated in the present evaluated libraries between 20 eV and 2 keV by 25%, on average, and up to 35% for certain evaluations and energy ranges.

  10. Preparation and characterization of 33S samples for 33S(n, α)30Si cross-section measurements at the n_TOF facility at CERN

    Science.gov (United States)

    Praena, J.; Ferrer, F. J.; Vollenberg, W.; Sabaté-Gilarte, M.; Fernández, B.; García-López, J.; Porras, I.; Quesada, J. M.; Altstadt, S.; Andrzejewski, J.; Audouin, L.; Bécares, V.; Barbagallo, M.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Billowes, J.; Boccone, V.; Bosnar, D.; Brugger, M.; Calviño, F.; Calviani, M.; Cano-Ott, D.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Colonna, N.; Cortés, G.; Cortés-Giraldo, M. A.; Diakaki, M.; Dietz, M.; Domingo-Pardo, C.; Dressler, R.; Durán, I.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Furman, V.; Göbel, K.; Gómez-Hornillos, M. B.; Ganesan, S.; García, A. R.; Giubrone, G.; Gonçalves, I. F.; González-Romero, E.; Goverdovski, A.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Heftrich, T.; Hernández-Prieto, A.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Karadimos, D.; Katabuchi, T.; Ketlerov, V.; Khryachkov, V.; Kivel, N.; Koehler, P.; Kokkoris, M.; Kroll, J.; Krtička, M.; Lampoudis, C.; Langer, C.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Leong, L. S.; Lerendegui-Marco, J.; Losito, R.; Mallick, A.; Manousos, A.; Marganiec, J.; Martínez, T.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Mondelaers, W.; Paradela, C.; Pavlik, A.; Perkowski, J.; Plompen, A. J. M.; Rauscher, T.; Reifarth, R.; Riego-Perez, A.; Robles, M.; Rubbia, C.; Ryan, J. A.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Sedyshev, P.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vermeulen, M. J.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiss, C.; Wright, T.; Žugec, P.; n TOF Collaboration

    2018-05-01

    Thin 33S samples for the study of the 33S(n, α)30Si cross-section at the n_TOF facility at CERN were made by thermal evaporation of 33S powder onto a dedicated substrate made of kapton covered with thin layers of copper, chromium and titanium. This method has provided for the first time bare sulfur samples a few centimeters in diameter. The samples have shown an excellent adherence with no mass loss after few years and no sublimation in vacuum at room temperature. The determination of the mass thickness of 33S has been performed by means of Rutherford backscattering spectrometry. The samples have been successfully tested under neutron irradiation.

  11. Measurement and analysis of the $^{243}$Am neutron capture cross section at the n_TOF facility at CERN

    CERN Document Server

    Mendoza, E; Guerrero, C; Berthoumieux, E; Abbondanno, U; Aerts, G; Alvarez-Velarde, F; Andriamonje, S; Andrzejewski, J; Assimakopoulos, P; Audouin, L; Badurek, G; Balibrea, J; Baumann, P; Becvar, F; Belloni, F; Calvino, F; Calviani, M; Capote, R; Carrapico, C; Carrillo de Albornoz, A; Cennini, P; Chepel, V; Chiaveri, E; Colonna, N; Cortes, G; Couture, A; Cox, J; Dahlfors, M; David, S; Dillmann, I; Dolfini, R; Domingo-Pardo, C; Dridi, W; Duran, I; Eleftheriadis, C; Ferrant†, L; Ferrari, A; Ferreira-Marques, R; Fitzpatrick, L; Frais-Koelbl, H; Fujii, K; Furman, W; Goncalves, I; Gonz alez-Romero, E; Goverdovski, A; Gramegna, F; Griesmayer, E; Gunsing, F; Haas, B; Haight, R; Heil, M; Herrera-Martinez, A; Igashira, M; Isaev, S; Jericha, E; Kappeler, F; Kadi, Y; Karadimos, D; Karamanis, D; Ketlerov, V; Kerveno, M; Koehler, P; Konovalov, V; Kossionides, E; Krticka, M; Lampoudis, C; Leeb, H; Lindote, A; Lopes, I; Lossito, R; Lozano, M; Lukic, S; Marganiec, J; Marques, L; Marrone, S; Martınez, T; Massimi, C; Mastinu, P; Mengoni, A; Milazzo, P M; Moreau, C; Mosconi, M; Neves, F; Oberhummer, H; O’Brien, S; Oshima, M; Pancin, J; Papachristodoulou, C; Papadopoulos, C; Paradela, C; Patronis, N; Pavlik, A; Pavlopoulos, P; Perrot, L; Pigni, M T; Plag, R; Plompen, A; Plukis, A; Poch, A; Praena, J; Pretel, C; Quesada, J; Rauscher, T; Reifarth, R; Rosetti, M; Rubbia, C; Rudolf, G; Rullhusen, P; Salgado, J; Santos, C; Sarchiapone, L; Savvidis, I; Stephan, C; Tagliente, G; Tain, J L; Tassan-Got, L; Tavora, L; Terlizzi, R; Vannini, G; Vaz, P; Ventura, A; Villamarin, D; Vicente, M C; Vlachoudis, V; Vlastou, R; Voss, F; Walter, S; Wendler, H; Wiescher, M; Wisshak, K

    2014-01-01

    Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$\\gamma$) cross section uncertainty. Method: The $^{243}$Am(n,$\\gamma$) cross section has been measured at the n_TOF facility at CERN with a BaF$_{2}$ Total Absorption Calorimeter, in the energy range between 0.7 eV and 2.5 keV. Results: The $^{243}$Am(n,$\\gamma$) cross section has been successfully measured in the mentioned energy range. The resolved resonance region has been extended from 250 eV up to 400 eV. In the unresolved resonance region our results are compatible with one of the two incompatible capture data sets available below 2.5 keV. The data available in EXFOR and in the literature has been used to perform a simple analysis above 2.5 keV. Conclusions: The results of this measurement contribute to reduce the $^{243}$Am(n,$\\gamma$) cross section uncertainty and suggest that this cross section is underestimate...

  12. submitter $^7 \\text{Be(n,} \\alpha)$ and $^7 \\text{Be(n,p)}$ cross-section measurement for the cosmological lithium problem at the n_TOF facility at CERN

    CERN Document Server

    Barbagallo, M; Aberle, O; Andrzejewski, J; Audouin, L; Bécares, V; Bacak, M; Balibrea, J; Barros, S; Bečvář, F; Beinrucker, C; Berthoumieux, E; Billowes, J; Bosnar, D; Brugger, M; Caamaño, M; Calviño, F; Calviani, M; Cano-Ott, D; Cardella, R; Casanovas, A; Castelluccio, D M; Cerutti, F; Chen, Y H; Chiaveri, E; Cortés, G; Cortés-Giraldo, M A; Cosentino, L; Damone, L A; Diakaki, M; Domingo-Pardo, C; Dressler, R; Dupont, E; Durán, I; Fernández-Domínguez, B; Ferrari, A; Ferreira, P; Finocchiaro, P; Furman, V; Göbel, K; García, A R; Gawlik, A; Glodariu, T; Gonçalves, I F; González, E; Goverdovski, A; Griesmayer, E; Guerrero, C; Gunsing, F; Harada, H; Heftrich, T; Heinitz, S; Heyse, J; Jenkins, D G; Jericha, E; Käppeler, F; Kadi, Y; Katabuchi, T; Kavrigin, P; Ketlerov, V; Khryachkov, V; Kimura, A; Kivel, N; Kokkoris, M; Krtička, M; Leal-Cidoncha, E; Lederer, C; Leeb, H; Lerendegui-Marco, J; Lo Meo, S; Lonsdale, S J; Losito, R; Macina, D; Marganiec, J; Martínez, T; Massimi, C; Mastinu, P; Mastromarco, M; Matteucci, F; Maugeri, E A; Mendoza, E; Mengoni, A; Milazzo, P M; Mingrone, F; Mirea, M; Montesano, S; Musumarra, A; Nolte, R; Oprea, A; Patronis, N; Pavlik, A; Perkowski, J; Porras, J I; Praena, J; Quesada, J M; Rajeev, K; Rauscher, T; Reifarth, R; Riego-Perez, A; Rout, P C; Rubbia, C; Ryan, J A; Sabaté-Gilarte, M; Saxena, A; Schillebeeckx, P; Schmidt, S; Schumann, D; Sedyshev, P; Smith, A G; Stamatopoulos, A; Tagliente, G; Tain, J L; Tarifeño-Saldivia, A; Tassan-Got, L; Tsinganis, A; Valenta, S; Vannini, G; Variale, V; Vaz, P; Ventura, A; Vlachoudis, V; Vlastou, R; Wallner, A; Warren, S; Weigand, M; Weiss, C; Wolf, C; Woods, P J; Wright, T; Žugec, P

    2017-01-01

    The Cosmological Lithium Problem refers to the large discrepancy between the abundance of primordial $^7$Li predicted by the standard theory of Big Bang Nucleosynthesis and the value inferred from the so-called “Spite plateau” in halo stars. A possible explanation for this longstanding puzzle in Nuclear Astrophysics is related to the incorrect estimation of the destruction rate of $^7$Be, which is responsible for the production of 95% of primordial Lithium. While charged-particle induced reactions have mostly been ruled out, data on the $^7 \\text{Be(n,} \\alpha)$ and $^7 \\text{Be(n,p)}$ reactions are scarce or completely missing, so that a large uncertainty still affects the abundance of $^7$Li predicted by the standard theory of Big Bang Nucleosynthesis. Both reactions have been measured at the n_TOF facility at CERN, providing for the first time data in a wide neutron energy range.

  13. Measurement of the U-234(n,f) cross section with PPAC detectors at the nTOF facility

    International Nuclear Information System (INIS)

    Dobarro, C.P.

    2005-06-01

    The aim of this work was twofold: to measure the 234 U neutron-induced fission cross section in an extended energy range with an unprecedented resolution, and, in the process, to validate the experimental method we used at the new n-TOF-CERN facility. The experiment was designed in order to take advantage of the unique characteristics of the n-TOF facility: the long flight path offers a high energy resolution and the high-intensity, instantaneous neutron flux greatly reduces the background from the sample activities, making it possible to measure highly radioactive samples. The fission detection setup is based on an innovative technique that benefits from the use of very thin targets and detectors. Up to nine targets of high purity fission samples are sandwiched by Parallel Plate Avalanche Counters (PPAC). When a fission event happens, the two complementary fission fragments are detected by the PPACs adjacent to the fissioning target in a narrow time coincidence. Because several targets are simultaneously placed in-beam, relative measurements with respect to reference nuclei can be obtained. In this work, an original data-reduction method has been developed to deal with the particular characteristics of both the n-TOF data acquisition system, which is based on very accurate Flash-ADC digitizers, and the fission detection setup. The data reduction includes the coincidence windows and the signal amplitude requirements that we obtained from preliminary data analysis. The applied coincidence method is very powerful for dealing with the background rejection such as contamination by α activity, which is quite high for 234 U, and the signals produced by highly energetic reactions in the detectors. The data-reduction method also implements the fission event reconstruction using the position information obtained from the stripped cathodes and the delay line readout, which makes it possible to determine the fission fragment angular distributions, and the time-of-flight to

  14. Differentiation of isomeric N-glycan structures by normal-phase liquid chromatography-MALDI-TOF/TOF tandem mass spectrometry.

    Science.gov (United States)

    Maslen, Sarah; Sadowski, Pawel; Adam, Alex; Lilley, Kathryn; Stephens, Elaine

    2006-12-15

    The detailed characterization of protein N-glycosylation is very demanding given the many different glycoforms and structural isomers that can exist on glycoproteins. Here we report a fast and sensitive method for the extensive structure elucidation of reducing-end labeled N-glycan mixtures using a combination of capillary normal-phase HPLC coupled off-line to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) and TOF/TOF-MS/MS. Using this method, isobaric N-glycans released from honey bee phospholipase A2 and Arabidopsis thaliana glycoproteins were separated by normal-phase chromatography and subsequently identified by key fragment ions in the MALDI-TOF/TOF tandem mass spectra. In addition, linkage and branching information were provided by abundant cross-ring and "elimination" fragment ions in the MALDI-CID spectra that gave extensive structural information. Furthermore, the fragmentation characteristics of N-glycans reductively aminated with 2-aminobenzoic acid and 2-aminobenzamide were compared. The identification of N-glycans containing 3-linked core fucose was facilitated by distinctive ions present only in the MALDI-CID spectra of 2-aminobenzoic acid-labeled oligosaccharides. To our knowledge, this is the first MS/MS-based technique that allows confident identification of N-glycans containing 3-linked core fucose, which is a major allergenic determinant on insect and plant glycoproteins.

  15. Investigation of Neutron-induced Reactions at n_TOF: an Overview of the 2009–2012 Experimental Program

    CERN Document Server

    Guerrero, C; Andrzejewski, J; Audouin, L; Barbagallo, M; Bécares, V; Bečvář, F; Belloni, F; Berthoumieux, E; Billowes, J; Boccone, V; Bosnar, D; Brugger, M; Calviani, M; Calviño, F; Cano-Ott, D; Carrapiço, C; Cerutti, F; Chiaveri, E; Chin, M; Colonna, N; Cortés, G; Cortés-Giraldo, M A; Diakaki, M; Domingo-Pardo, C; Duran, I; Dressler, R; Dzysiuk, N; Eleftheriadis, C; Ferrari, A; Fraval, K; Ganesan, S; García, A R; Giubrone, G; Gómez-Hornillos, M B; Gonçalves, I F; González-Romero, E; Griesmayer, E; Gunsing, F; Gurusamy, P; Jenkins, D G; Jericha, E; Kadi, Y; Käppeler, F; Karadimos, D; Kivel, N; Koehler, P; Kokkoris, M; Korschinek, G; Krtička, M; Kroll, J; Langer, C; Lederer, C; Leeb, H; Leong, L S; Losito, R; Manousos, A; Marganiec, J; Martínez, T; Mastinu, P F; Mastromarco, M; Massimi, C; Meaze, M; Mendoza, E; Mengoni, A; Milazzo, P M; Mingrone, F; Mirea, M; Mondelaers, W; Paradela, C; Pavlik, A; Perkowski, J; Pignatari, M; Plompen, A; Praena, J; Quesada, J M; Rauscher, T; Reifarth, R; Riego, A; Roman, F; Rubbia, C; Sarmento, R; Schillebeeckx, P; Schmidt, S; Schumann, D; Tagliente, G; Tain, J L; Tarrío, D; Tassan-Got, L; Tsinganis, A; Valenta, S; Vannini, G; Variale, V; Vaz, P; Ventura, A; Versaci, R; Vermeulen, M J; Vlachoudis, V; Vlastou, R; Wallner, A; Ware, T; Weigand, M; Weiß, C; Wright, T J; Žugec, P

    2014-01-01

    The neutron time-of-flight facility n\\_TOF is operating at CERN (Switzerland) since 2001, having started in 2009 a new campaign with an upgraded spallation target. The ambitious program carried out includes a large number of experiments in nuclear technology, astrophysics, basic physics, detector development and medical applications. This paper is devoted to the physics program at n\\_TOF and the measurements performed between 2009 and 2012. Special attention is given to those experiments that have been most challenging, are more important for a particular field, have reached unprecedented levels of accuracy, or have been carried out for the first time ever.

  16. Measurement of the radiative capture cross section of the s-process branching points 204Tl and 171Tm at the n_TOF facility (CERN)

    Science.gov (United States)

    Casanovas, A.; Domingo-Pardo, C.; Guerrero, C.; Lerendegui-Marco, J.; Calviño, F.; Tarifeño-Saldivia, A.; Dressler, R.; Heinitz, S.; Kivel, N.; Quesada, J. M.; Schumann, D.; Aberle, O.; Alcayne, V.; Andrzejewski, J.; Audouin, L.; Bécares, V.; Bacak, M.; Barbagallo, M.; Bečvář, F.; Bellia, G.; Berthoumieux, E.; Billowes, J.; Bosnar, D.; Brown, A.; Busso, M.; Caamaño, M.; Caballero-Ontanaya, L.; Calviani, M.; Cano-Ott, D.; Cerutti, F.; Chen, Y. H.; Chiaveri, E.; Colonna, N.; Cortés, G.; Cortés-Giraldo, M. A.; Cosentino, L.; Cristallo, S.; Damone, L. A.; Diakaki, M.; Dietz, M.; Dupont, E.; Durán, I.; Eleme, Z.; Fernández-Domínguez, B.; Ferrari, A.; Ferreira, P.; Finocchiaro, P.; Furman, V.; Göbel, K.; Gawlik, A.; Gilardoni, S.; Glodariu, T.; Gonçalves, I. F.; González-Romero, E.; Gunsing, F.; Heyse, J.; Jenkins, D. G.; Käppeler, F.; Kadi, Y.; Katabuchi, T.; Kimura, A.; Kokkoris, M.; Kopatch, Y.; Krtička, M.; Kurtulgil, D.; Ladarescu, I.; Lederer-Woods, C.; Meo, S. Lo; Lonsdale, S. J.; Macina, D.; Martínez, T.; Masi, A.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Matteucci, F.; Maugeri, E. A.; Mazzone, A.; Mendoza, E.; Mengoni, A.; Michalopoulou, V.; Milazzo, P. M.; Mingrone, F.; Musumarra, A.; Negret, A.; Nolte, R.; Ogállar, F.; Oprea, A.; Patronis, N.; Pavlik, A.; Perkowski, J.; Persanti, L.; Porras, I.; Praena, J.; Radeck, D.; Ramos, D.; Rauscher, T.; Reifarth, R.; Rochman, D.; Sabaté-Gilarte, M.; Saxena, A.; Schillebeeckx, P.; Simone, S.; Smith, A. G.; Sosnin, N. V.; Stamatopoulos, A.; Tagliente, G.; Tain, J. L.; Talip, T.; Tassan-Got, L.; Tsinganis, A.; Ulrich, J.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Woods, P. J.; Wright, T.; Žugec, P.; Köster, U.

    2018-05-01

    The neutron capture cross section of some unstable nuclei is especially relevant for s-process nucleosynthesis studies. This magnitude is crucial to determine the local abundance pattern, which can yield valuable information of the s-process stellar environment. In this work we describe the neutron capture (n,γ) measurement on two of these nuclei of interest, 204Tl and 171Tm, from target production to the final measurement, performed successfully at the n_TOF facility at CERN in 2014 and 2015. Preliminary results on the ongoing experimental data analysis will also be shown. These results include the first ever experimental observation of capture resonances for these two nuclei.

  17. Measurement of cross-sections of fission reactions induced by neutrons on actinides from the thorium cycle at n-TOF facility

    International Nuclear Information System (INIS)

    Ferrant, L.

    2005-09-01

    In the frame of innovating energy source system studies, thorium fuel cycle reactors are considered. Neutron induced fission cross section on such cycle involved actinides play a role in scenario studies. To feed them, data bases are built with experimental results and nuclear models. For some nuclei, they are not complete or in disagreement. In order to complete these data bases, we have built an original set up, consisting in an alternation of PPACs (Parallel Plate Avalanche Chamber) and ultra - thin targets, which we installed on n-TOF facility. We describe detectors, set up, and the particular care brought to target making and characterization. Fission products in coincidence are detected with precise time measurement and localization with delay line read out method. We contributed, within the n-TOF collaboration, to the CERN brand new intense spallation neutron source characterization, based on time of flight measurement, and we describe its characteristics and performances. We were able to measure such actinide fission cross sections as 232 Th, 234 U, 233 U, 237 Np, 209 Bi, and nat Pb relative to 235 U et 238 U standards, using an innovative acquisition system. We took advantage of the lame accessible energy field, from 0.7 eV to 1 GeV, combined with the excellent energy resolution in this field. Data treatment and analysis advancement are described to enlighten performance and limits of the obtained results. (author)

  18. The MR-TOF-MS isobar separator for the TITAN facility at TRIUMF

    Energy Technology Data Exchange (ETDEWEB)

    Jesch, Christian; Dickel, Timo, E-mail: t.dickel@gsi.de; Plaß, Wolfgang R. [Justus-Liebig-University (Germany); Short, Devin [Simon Fraser University (Canada); Ayet San Andres, Samuel [Justus-Liebig-University (Germany); Dilling, Jens [TRIUMF (Canada); Geissel, Hans; Greiner, Florian; Lang, Johannes [Justus-Liebig-University (Germany); Leach, Kyle G. [Simon Fraser University (Canada); Lippert, Wayne; Scheidenberger, Christoph [Justus-Liebig-University (Germany); Yavor, Mikhail I. [Institute for Analytical Instrumentation, Russian Academy of Science (Russian Federation)

    2015-11-15

    At TRIUMF’s Ion Trap for Atomic and Nuclear Science (TITAN) a multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) will extend TITAN’s capabilities and facilitate mass measurements and in-trap decay spectroscopy of exotic nuclei that so far have not been possible due to strong isobaric contamination. This MR-TOF-MS will also enable mass measurements of very short-lived nuclides (half-life > 1 ms) that are produced in very low quantities (a few detected ions overall). In order to allow the installation of an MR-TOF-MS in the restricted space on the platform, on which the TITAN facility is located, novel mass spectrometric methods have been developed. Transport, cooling and distribution of the ions inside the device is done using a buffer gas-filled RFQ-based ion beam switchyard. Mass selection is achieved using a dynamic retrapping technique after time-of-flight analysis in an electrostatic isochronous reflector system. Only due to the combination of these novel methods the realization of an MR-TOF-MS based isobar separator at TITAN has become possible. The device has been built, commissioned off-line and is currently under installation at TITAN.

  19. The MR-TOF-MS isobar separator for the TITAN facility at TRIUMF

    Science.gov (United States)

    Jesch, Christian; Dickel, Timo; Plaß, Wolfgang R.; Short, Devin; Ayet San Andres, Samuel; Dilling, Jens; Geissel, Hans; Greiner, Florian; Lang, Johannes; Leach, Kyle G.; Lippert, Wayne; Scheidenberger, Christoph; Yavor, Mikhail I.

    2015-11-01

    At TRIUMF's Ion Trap for Atomic and Nuclear Science (TITAN) a multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) will extend TITAN's capabilities and facilitate mass measurements and in-trap decay spectroscopy of exotic nuclei that so far have not been possible due to strong isobaric contamination. This MR-TOF-MS will also enable mass measurements of very short-lived nuclides (half-life > 1 ms) that are produced in very low quantities (a few detected ions overall). In order to allow the installation of an MR-TOF-MS in the restricted space on the platform, on which the TITAN facility is located, novel mass spectrometric methods have been developed. Transport, cooling and distribution of the ions inside the device is done using a buffer gas-filled RFQ-based ion beam switchyard. Mass selection is achieved using a dynamic retrapping technique after time-of-flight analysis in an electrostatic isochronous reflector system. Only due to the combination of these novel methods the realization of an MR-TOF-MS based isobar separator at TITAN has become possible. The device has been built, commissioned off-line and is currently under installation at TITAN.

  20. The Nuclear Astrophysics program at n_TOF (CERN

    Directory of Open Access Journals (Sweden)

    Colonna N.

    2017-01-01

    Full Text Available An important experimental program on Nuclear Astrophysics is being carried out at the n_TOF since several years, in order to address the still open issues in stellar and primordial nucleosynthesis. Several neutron capture reactions relevant to s-process nucleosynthesis have been measured so far, some of which on important branching point radioisotopes. Furthermore, the construction of a second experimental area has recently opened the way to challenging measurements of (n, charged particle reactions on isotopes of short half-life. The Nuclear Astrophysics program of the n_TOF Collaboration is here described, with emphasis on recent results relevant for stellar nucleosynthesis, stellar neutron sources and primordial nucleosynthesis.

  1. High-accuracy determination of the neutron flux in the new experimental area nTOF-EAR2 at CERN

    Energy Technology Data Exchange (ETDEWEB)

    Sabate-Gilarte, M. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Universidad de Sevilla, Departamento de Fisica Atomica, Molecular y Nuclear, Sevilla (Spain); Barbagallo, M.; Colonna, N.; Damone, L.; Belloni, F.; Mastromarco, M.; Tagliente, G.; Variale, V. [Istituto Nazionale di Fisica Nucleare, Sezione di Bari, Bari (Italy); Gunsing, F.; Berthoumieux, E.; Diakaki, M.; Papaevangelou, T.; Dupont, E. [Universite Paris-Saclay, CEA Irfu, Gif-sur-Yvette (France); Zugec, P.; Bosnar, D. [University of Zagreb, Department of Physics, Faculty of Science, Zagreb (Croatia); Vlachoudis, V.; Aberle, O.; Brugger, M.; Calviani, M.; Cardella, R.; Cerutti, F.; Chiaveri, E.; Ferrari, A.; Kadi, Y.; Losito, R.; Macina, D.; Montesano, S.; Rubbia, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Chen, Y.H.; Audouin, L.; Tassan-Got, L. [Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay (France); Stamatopoulos, A.; Kokkoris, M.; Tsinganis, A.; Vlastou, R. [National Technical University of Athens (NTUA), Athens (Greece); Lerendegui-Marco, J.; Cortes-Giraldo, M.A.; Guerrero, C.; Quesada, J.M. [Universidad de Sevilla, Departamento de Fisica Atomica, Molecular y Nuclear, Sevilla (Spain); Villacorta, A. [University of Salamanca, Salamanca (Spain); Cosentino, L.; Finocchiaro, P.; Piscopo, M. [INFN, Laboratori Nazionali del Sud, Catania (Italy); Musumarra, A. [INFN, Laboratori Nazionali del Sud, Catania (Italy); Universita di Catania, Dipartimento di Fisica, Catania (Italy); Andrzejewski, J.; Gawlik, A.; Marganiec, J.; Perkowski, J. [University of Lodz, Lodz (Poland); Becares, V.; Balibrea, J.; Cano-Ott, D.; Garcia, A.R.; Gonzalez, E.; Martinez, T.; Mendoza, E. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain); Bacak, M.; Weiss, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Technische Universitaet Wien, Wien (Austria); Baccomi, R.; Milazzo, P.M. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, Trieste (Italy); Barros, S.; Ferreira, P.; Goncalves, I.F.; Vaz, P. [Instituto Superior Tecnico, Lisbon (Portugal); Becvar, F.; Krticka, M.; Valenta, S. [Charles University, Prague (Czech Republic); Beinrucker, C.; Goebel, K.; Heftrich, T.; Reifarth, R.; Schmidt, S.; Weigand, M.; Wolf, C. [Goethe University Frankfurt, Frankfurt (Germany); Billowes, J.; Frost, R.J.W.; Ryan, J.A.; Smith, A.G.; Warren, S.; Wright, T. [University of Manchester, Manchester (United Kingdom); Caamano, M.; Deo, K.; Duran, I.; Fernandez-Dominguez, B.; Leal-Cidoncha, E.; Paradela, C.; Robles, M.S. [University of Santiago de Compostela, Santiago de Compostela (Spain); Calvino, F.; Casanovas, A.; Riego-Perez, A. [Universitat Politecnica de Catalunya, Barcelona (Spain); Castelluccio, D.M.; Lo Meo, S. [Agenzia Nazionale per le Nuove Tecnologie (ENEA), Bologna (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (Italy); Cortes, G.; Mengoni, A. [Agenzia Nazionale per le Nuove Tecnologie (ENEA), Bologna (Italy); Domingo-Pardo, C.; Tain, J.L. [Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (Spain); Dressler, R.; Heinitz, S.; Kivel, N.; Maugeri, E.A.; Schumann, D. [Paul Scherrer Institut (PSI), Villingen (Switzerland); Furman, V.; Sedyshev, P. [Joint Institute for Nuclear Research (JINR), Dubna (Russian Federation); Gheorghe, I.; Glodariu, T.; Mirea, M.; Oprea, A. [Horia Hulubei National Institute of Physics and Nuclear Engineering, Magurele (Romania); Goverdovski, A.; Ketlerov, V.; Khryachkov, V. [Institute of Physics and Power Engineering (IPPE), Obninsk (Russian Federation); Griesmayer, E.; Jericha, E.; Kavrigin, P.; Leeb, H. [Technische Universitaet Wien, Wien (Austria); Harada, H.; Kimura, A. [Japan Atomic Energy Agency (JAEA), Tokai-mura (Japan); Hernandez-Prieto, A. [European Organization for Nuclear Research (CERN), Geneva (CH); Universitat Politecnica de Catalunya, Barcelona (ES); Heyse, J.; Schillebeeckx, P. [European Commission, Joint Research Centre, Geel (BE); Jenkins, D.G. [University of York, York (GB); Kaeppeler, F. [Karlsruhe Institute of Technology, Karlsruhe (DE); Katabuchi, T. [Tokyo Institute of Technology, Tokyo (JP); Lederer, C.; Lonsdale, S.J.; Woods, P.J. [University of Edinburgh, School of Physics and Astronomy, Edinburgh (GB); Licata, M.; Massimi, C.; Vannini, G. [Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (IT); Universita di Bologna, Dipartimento di Fisica e Astronomia, Bologna (IT); Mastinu, P. [Istituto Nazionale di Fisica Nucleare, Sezione di Legnaro, Legnaro (IT); Matteucci, F. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, Trieste (IT); Universita di Trieste, Dipartimento di Astronomia, Trieste (IT); Mingrone, F. [European Organization for Nuclear Research (CERN), Geneva (CH); Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (IT); Nolte, R. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (DE); Palomo-Pinto, F.R. [Universidad de Sevilla, Dept. Ingenieria Electronica, Escuela Tecnica Superior de Ingenieros, Sevilla (ES); Patronis, N. [University of Ioannina, Ioannina (GR); Pavlik, A. [University of Vienna, Faculty of Physics, Vienna (AT); Porras, J.I. [University of Granada, Granada (ES); Praena, J. [Universidad de Sevilla, Departamento de Fisica Atomica, Molecular y Nuclear, Sevilla (ES); University of Granada, Granada (ES); Rajeev, K.; Rout, P.C.; Saxena, A.; Suryanarayana, S.V. [Bhabha Atomic Research Centre (BARC), Mumbai (IN); Rauscher, T. [University of Hertfordshire, Centre for Astrophysics Research, Hatfield (GB); University of Basel, Department of Physics, Basel (CH); Tarifeno-Saldivia, A. [Universitat Politecnica de Catalunya, Barcelona (ES); Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (ES); Ventura, A. [Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna (IT); Wallner, A. [Australian National University, Canberra (AU)

    2017-10-15

    A new high flux experimental area has recently become operational at the nTOF facility at CERN. This new measuring station, nTOF-EAR2, is placed at the end of a vertical beam line at a distance of approximately 20 m from the spallation target. The characterization of the neutron beam, in terms of flux, spatial profile and resolution function, is of crucial importance for the feasibility study and data analysis of all measurements to be performed in the new area. In this paper, the measurement of the neutron flux, performed with different solid-state and gaseous detection systems, and using three neutron-converting reactions considered standard in different energy regions is reported. The results of the various measurements have been combined, yielding an evaluated neutron energy distribution in a wide energy range, from 2 meV to 100 MeV, with an accuracy ranging from 2%, at low energy, to 6% in the high-energy region. In addition, an absolute normalization of the nTOF-EAR2 neutron flux has been obtained by means of an activation measurement performed with {sup 197}Au foils in the beam. (orig.)

  2. Development of a TOF SIMS setup at the Zagreb heavy ion microbeam facility

    Science.gov (United States)

    Tadić, Tonči; Bogdanović Radović, Iva; Siketić, Zdravko; Cosic, Donny Domagoj; Skukan, Natko; Jakšić, Milko; Matsuo, Jiro

    2014-08-01

    We describe a new Time-of-flight Secondary Ion Mass Spectrometry (TOF SIMS) setup for MeV SIMS application, which is constructed and installed at the heavy ion microbeam facility at the Ruđer Bošković Institute in Zagreb. The TOF-SIMS setup is developed for high sensitivity molecular imaging using a heavy ion microbeam that focuses ion beams (from C to I) with sub-micron resolution. Dedicated pulse processing electronics for MeV SIMS application have been developed, enabling microbeam-scanning control, incoming ion microbeam pulsing and molecular mapping. The first results showing measured MeV SIMS spectra as well as molecular maps for samples of interest are presented and discussed.

  3. Development of a TOF SIMS setup at the Zagreb heavy ion microbeam facility

    International Nuclear Information System (INIS)

    Tadić, Tonči; Bogdanović Radović, Iva; Siketić, Zdravko; Cosic, Donny Domagoj; Skukan, Natko; Jakšić, Milko; Matsuo, Jiro

    2014-01-01

    We describe a new Time-of-flight Secondary Ion Mass Spectrometry (TOF SIMS) setup for MeV SIMS application, which is constructed and installed at the heavy ion microbeam facility at the Ruđer Bošković Institute in Zagreb. The TOF-SIMS setup is developed for high sensitivity molecular imaging using a heavy ion microbeam that focuses ion beams (from C to I) with sub-micron resolution. Dedicated pulse processing electronics for MeV SIMS application have been developed, enabling microbeam-scanning control, incoming ion microbeam pulsing and molecular mapping. The first results showing measured MeV SIMS spectra as well as molecular maps for samples of interest are presented and discussed

  4. GEANT4 simulations of the n{sub T}OF spallation source and their benchmarking

    Energy Technology Data Exchange (ETDEWEB)

    Lo Meo, S. [Research Centre ' ' Ezio Clementel' ' , ENEA, Bologna (Italy); Section of Bologna, INFN, Bologna (Italy); Cortes-Giraldo, M.A.; Lerendegui-Marco, J.; Guerrero, C.; Quesada, J.M. [Universidad de Sevilla, Facultad de Fisica, Sevilla (Spain); Massimi, C.; Vannini, G. [Section of Bologna, INFN, Bologna (Italy); University of Bologna, Physics and Astronomy Dept. ' ' Alma Mater Studiorum' ' , Bologna (Italy); Barbagallo, M.; Colonna, N. [INFN, Section of Bari, Bari (Italy); Mancusi, D. [CEA-Saclay, DEN, DM2S, SERMA, LTSD, Gif-sur-Yvette CEDEX (France); Mingrone, F. [Section of Bologna, INFN, Bologna (Italy); Sabate-Gilarte, M. [Universidad de Sevilla, Facultad de Fisica, Sevilla (Spain); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Vlachoudis, V. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Collaboration: The n_TOF Collaboration

    2015-12-15

    Neutron production and transport in the spallation target of the n{sub T}OF facility at CERN has been simulated with GEANT4. The results obtained with different models of high-energy nucleon-nucleus interaction have been compared with the measured characteristics of the neutron beam, in particular the flux and its dependence on neutron energy, measured in the first experimental area. The best agreement at present, within 20% for the absolute value of the flux, and within few percent for the energy dependence in the whole energy range from thermal to 1 GeV, is obtained with the INCL++ model coupled with the GEANT4 native de-excitation model. All other available models overestimate by a larger factor, of up to 70%, the n{sub T}OF neutron flux. The simulations are also able to accurately reproduce the neutron beam energy resolution function, which is essentially determined by the moderation time inside the target/moderator assembly. The results here reported provide confidence on the use of GEANT4 for simulations of spallation neutron sources. (orig.)

  5. Measurement of the 238U(n ,γ ) cross section up to 80 keV with the Total Absorption Calorimeter at the CERN n_TOF facility

    Science.gov (United States)

    Wright, T.; Guerrero, C.; Billowes, J.; Cano-Ott, D.; Mendoza, E.; Altstadt, S.; Andrzejewski, J.; Audouin, L.; Bécares, V.; Barbagallo, M.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Bosnar, D.; Brugger, M.; Calviño, F.; Calviani, M.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Colonna, N.; Cortés, G.; Cortés-Giraldo, M. A.; Diakaki, M.; Dietz, M.; Domingo-Pardo, C.; Durán, I.; Dzysiuk, N.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Furman, V.; Gómez-Hornillos, M. B.; Ganesan, S.; García, A. R.; Giubrone, G.; Gonçalves, I. F.; González-Romero, E.; Goverdovski, A.; Griesmayer, E.; Gunsing, F.; Gurusamy, P.; Heftrich, T.; Hernández-Prieto, A.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Karadimos, D.; Katabuchi, T.; Ketlerov, V.; Khryachkov, V.; Koehler, P.; Kokkoris, M.; Kroll, J.; Krtička, M.; Lampoudis, C.; Langer, C.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Leong, L. S.; Lerendegui-Marco, J.; Losito, R.; Manousos, A.; Marganiec, J.; Martínez, T.; Massimi, C.; Mastinu, P.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Paradela, C.; Pavlik, A.; Perkowski, J.; Praena, J.; Quesada, J. M.; Rauscher, T.; Reifarth, R.; Riego-Perez, A.; Robles, M.; Roman, F.; Rubbia, C.; Ryan, J. A.; Sabaté-Gilarte, M.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Sedyshev, P.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vermeulen, M. J.; Versaci, R.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiss, C.; Žugec, P.; n TOF Collaboration

    2017-12-01

    The radiative capture cross section of a highly pure (99.999%), 6.125(2) grams and 9.56(5)×10-4 atoms/barn areal density 238U sample has been measured with the Total Absorption Calorimeter (TAC) in the 185 m flight path at the CERN neutron time-of-flight facility n_TOF. This measurement is in response to the NEA High Priority Request list, which demands an accuracy in this cross section of less than 3% below 25 keV. These data have undergone careful background subtraction, with special care being given to the background originating from neutrons scattered by the 238U sample. Pileup and dead-time effects have been corrected for. The measured cross section covers an energy range between 0.2 eV and 80 keV, with an accuracy that varies with neutron energy, being better than 4% below 25 keV and reaching at most 6% at higher energies.

  6. Characterizing Neutron Diagnostics on the nTOF Line at SUNY Geneseo

    Science.gov (United States)

    Harrison, Hannah; Seppala, Hannah; Visca, Hannah; Wakwella, Praveen; Fletcher, Kurt; Padalino, Stephen; Forrest, Chad; Regan, Sean; Sangster, Craig

    2016-10-01

    Charged particle beams from SUNY Geneseo's 1.7 MV Tandem Pelletron Accelerator induce nuclear reactions that emit neutrons ranging from 0.5 to 17.9 MeV via 2H(d,n)3He and 11B(d,n)12C. This adjustable neutron source can be used to calibrate ICF and HEDP neutron scintillators for ICF diagnostics. However, gamma rays and muons, which are often present during an accelerator-based calibration, are difficult to differentiate from neutron signals in scintillators. To mitigate this problem, a new neutron time-of-flight (nTOF) line has been constructed. The nTOF timing is measured using the associated particle technique. A charged particle produced by the nuclear reaction serves as a start signal, while its associated neutron is the stop signal. Each reaction is analyzed event-by-event to determine whether the scintillator signal was generated by a neutron, gamma or muon. Using this nTOF technique, the neutron response for different scintillation detectors can be determined. Funded in part by a LLE contract through the DOE.

  7. Measurement of the $^{12}$C($n,p$)$^{12}$B cross section at n_TOF (CERN) by in-beam activation analysis

    CERN Document Server

    Žugec, P.; Bosnar, D.; Mengoni, A.; Altstadt, S.; Andrzejewski, J.; Audouin, L.; Barbagallo, M.; Bécares, V.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Billowes, J.; Boccone, V.; Brugger, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Cortés, G.; Cortés-Giraldo, M.A.; Cosentino, L.; Diakaki, M.; Domingo-Pardo, C.; Dressler, R.; Duran, I.; Eleftheriadis, C.; Ferrari, A.; Finocchiaro, P.; Fraval, K.; Ganesan, S.; García, A.R.; Giubrone, G.; Gómez-Hornillos, M.B.; Gonçalves, I.F.; González-Romero, E.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Gurusamy, P.; Heinitz, S.; Jenkins, D.G.; Jericha, E.; Käppeler, F.; Karadimos, D.; Kivel, N.; Kokkoris, M.; Krtička, M.; Kroll, J.; Langer, C.; Lederer, C.; Leeb, H.; Leong, L.S.; Lo Meo, S.; Losito, R.; Manousos, A.; Marganiec, J.; Martínez, T.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Mendoza, E.; Milazzo, P.M.; Mingrone, F.; Mirea, M.; Mondalaers, W.; Musumarra, A.; Paradela, C.; Pavlik, A.; Perkowski, J.; Plompen, A.; Praena, J.; Quesada, J.; Rauscher, T.; Reifarth, R.; Riego, A.; Roman, F.; Rubbia, C.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Tagliente, G.; Tain, J.L.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Versaci, R.; Vermeulen, M.J.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiß, C.; Wright, T.

    2014-01-01

    The integral cross section of the $^{12}$C($n,p$)$^{12}$B reaction has been determined for the first time in the neutron energy range from threshold to several GeV at the n_TOF facility at CERN. The measurement relies on the activation technique, with the $\\beta$-decay of $^{12}$B measured over a period of four half-lives within the same neutron bunch in which the reaction occurs. The results indicate that model predictions, used in a variety of applications, are mostly inadequate. The value of the integral cross section reported here can be used as a benchmark for verifying or tuning model calculations.

  8. ^{7}Be(n,α)^{4}He Reaction and the Cosmological Lithium Problem: Measurement of the Cross Section in a Wide Energy Range at n_TOF at CERN.

    Science.gov (United States)

    Barbagallo, M; Musumarra, A; Cosentino, L; Maugeri, E; Heinitz, S; Mengoni, A; Dressler, R; Schumann, D; Käppeler, F; Colonna, N; Finocchiaro, P; Ayranov, M; Damone, L; Kivel, N; Aberle, O; Altstadt, S; Andrzejewski, J; Audouin, L; Bacak, M; Balibrea-Correa, J; Barros, S; Bécares, V; Bečvář, F; Beinrucker, C; Berthoumieux, E; Billowes, J; Bosnar, D; Brugger, M; Caamaño, M; Calviani, M; Calviño, F; Cano-Ott, D; Cardella, R; Casanovas, A; Castelluccio, D M; Cerutti, F; Chen, Y H; Chiaveri, E; Cortés, G; Cortés-Giraldo, M A; Cristallo, S; Diakaki, M; Domingo-Pardo, C; Dupont, E; Duran, I; Fernandez-Dominguez, B; Ferrari, A; Ferreira, P; Furman, W; Ganesan, S; García-Rios, A; Gawlik, A; Glodariu, T; Göbel, K; Gonçalves, I F; González-Romero, E; Griesmayer, E; Guerrero, C; Gunsing, F; Harada, H; Heftrich, T; Heyse, J; Jenkins, D G; Jericha, E; Katabuchi, T; Kavrigin, P; Kimura, A; Kokkoris, M; Krtička, M; Leal-Cidoncha, E; Lerendegui, J; Lederer, C; Leeb, H; Lo Meo, S; Lonsdale, S J; Losito, R; Macina, D; Marganiec, J; Martínez, T; Massimi, C; Mastinu, P; Mastromarco, M; Mazzone, A; Mendoza, E; Milazzo, P M; Mingrone, F; Mirea, M; Montesano, S; Nolte, R; Oprea, A; Pappalardo, A; Patronis, N; Pavlik, A; Perkowski, J; Piscopo, M; Plompen, A; Porras, I; Praena, J; Quesada, J; Rajeev, K; Rauscher, T; Reifarth, R; Riego-Perez, A; Rout, P; Rubbia, C; Ryan, J; Sabate-Gilarte, M; Saxena, A; Schillebeeckx, P; Schmidt, S; Sedyshev, P; Smith, A G; Stamatopoulos, A; Tagliente, G; Tain, J L; Tarifeño-Saldivia, A; Tassan-Got, L; Tsinganis, A; Valenta, S; Vannini, G; Variale, V; Vaz, P; Ventura, A; Vlachoudis, V; Vlastou, R; Vollaire, J; Wallner, A; Warren, S; Weigand, M; Weiß, C; Wolf, C; Woods, P J; Wright, T; Žugec, P

    2016-10-07

    The energy-dependent cross section of the ^{7}Be(n,α)^{4}He reaction, of interest for the so-called cosmological lithium problem in big bang nucleosynthesis, has been measured for the first time from 10 meV to 10 keV neutron energy. The challenges posed by the short half-life of ^{7}Be and by the low reaction cross section have been overcome at n_TOF thanks to an unprecedented combination of the extremely high luminosity and good resolution of the neutron beam in the new experimental area (EAR2) of the n_TOF facility at CERN, the availability of a sufficient amount of chemically pure ^{7}Be, and a specifically designed experimental setup. Coincidences between the two alpha particles have been recorded in two Si-^{7}Be-Si arrays placed directly in the neutron beam. The present results are consistent, at thermal neutron energy, with the only previous measurement performed in the 1960s at a nuclear reactor. The energy dependence reported here clearly indicates the inadequacy of the cross section estimates currently used in BBN calculations. Although new measurements at higher neutron energy may still be needed, the n_TOF results hint at a minor role of this reaction in BBN, leaving the long-standing cosmological lithium problem unsolved.

  9. Neutron spectrum measurement by TOF

    International Nuclear Information System (INIS)

    Aizawa, Otohiko

    1982-01-01

    The TOF experiments by using various facilities are described. The steady neutron spectra in light water which contains non-1/V absorbing materials were measured by the TOF method at a LINAC facility. The results were compared with the calculations based on the Koppel-Haywood model and two others. The leakage neutron spectra from a heavy-water assembly were measured and compared with model calculations. The time-dependent energy spectra in a small graphite assembly were measured. For this measurement, a chopper system was also used. The two-region calculation explains the spectrum just after the neutron burst. The time-dependent spectra in a small Be assembly and in an assembly of coolant-moderator containing hydrogen were also measured. The calculations based on various models are in progress. The TOF experiments at the reactor-chopper facility were carried out for measuring the total cross sections of crystalline moderators, the thermal neutron total cross section of high temperature beryllium, the thermal neutron total cross sections of granular lead and high temperature liquid lead, and the angle-dependent scattering spectra. A pseudo-chopper was designed and constructed. The spectra of the neutron field for medical use were measured by the chopper-TOF system. The thermal neutron total cross sections of Fe, Zr, Nb and Mg were measured, and the results were compared with the calculations by THRUSH and UNCLE-TOM codes. The random-trigger TOF experiments were made by using Cf-252. (Kato, T.)

  10. High-precision Measurement of the 238U(n,γ) Cross Section with the Total Absorption Calorimeter (TAC) at n_TOF, CERN

    CERN Document Server

    Wright, T; Billowes, J; Ware, T; Cano-Ott, D; Mendoza, E; Massimi, C; Mingrone, F; Gunsing, F; Berthoumieux, E; Lampoudis, C; Altstadt, S; Andrzejewski, J; Audouin, L; Barbagallo, M; Bécares, V; Bečvář, F; Belloni, F; Boccone, V; Bosnar, D; Brugger, M; Calviani, M; Calviño, F; Carrapiço, C; Cerutti, F; Chiaveri, E; Chin, M; Colonna, N; Cortés, G; Cortés-Giraldo, M A; Diakaki, M; Domingo-Pardo, C; Duran, I; Dressler, R; Dzysiuk, N; Eleftheriadis, C; Ferrari, A; Fraval, K; Ganesan, S; García, A R; Gómez-Hornillos, M B; Gonçalves, I F; González-Romero, E; Griesmayer, E; Giubrone, G; Gurusamy, P; Jenkins, D G; Jericha, E; Kadi, Y; Käppeler, F; Karadimos, D; Kivel, N; Koehler, P; Kokkoris, M; Korschinek, G; Krtička, M; Kroll, J; Langer, C; Lederer, C; Leeb, H; Leong, L S; Losito, R; Manousos, A; Marganiec, J; Martínez, T; Mastinu, P F; Mastromarco, M; Meaze, M; Mengoni, A; Milazzo, P M; Mirea, M; Mondelaers, W; Paradela, C; Pavlik, A; Perkowski, J; Pignatari, M; Plompen, A; Praena, J; Quesada, J M; Rauscher, T; Reifarth, R; Riego, A; Roman, F; Rubbia, C; Sarmento, R; Schillebeeckx, P; Schmidt, S; Schumann, D; Tagliente, G; Tain, J L; Tarrío, D; Tassan-Got, L; Tsinganis, A; Valenta, S; Vannini, G; Variale, V; Vaz, P; Ventura, A; Versaci, R; Vermeulen, M J; Vlachoudis, V; Vlastou, R; Wallner, A; Weigand, M; Weiß, C; Žugec, P

    2014-01-01

    The neutron capture cross section of U-238 is fundamental to the design and operation of current reactors and future fast nuclear reactors, and thus must be measured to a high level of accuracy. An experiment has been performed at the CERN n TOF facility using a 4 pi Total Absorption Calorimeter (TAC) to measure the capture cross section in the resolved resonance region between 1 eV and 25 keV. A preliminary analysis of the TAC data is presented with particular emphasis to the experimental background in this energy region of interest.

  11. Measurement of the neutron capture cross section of U{sup 234} in n-TOF at CERN for Generation IV nuclear reactors; Mesure de la section efficace de capture neutronique de l'{sup 234}U a n-TOF au CERN pour les reacteurs nucleaires de generation 4

    Energy Technology Data Exchange (ETDEWEB)

    Dridi, W

    2006-11-15

    Accurate and reliable neutron capture cross sections are needed in many research areas, including stellar nucleosynthesis, advanced nuclear fuel cycles, waste transmutation, and other applied programs. In particular, the accurate knowledge of U{sup 234}(n,{gamma}) reaction cross section is required for the design and realization of nuclear power plants based on the thorium fuel cycle. We have measured the neutron capture cross section of U{sup 234}, with a 4{pi} BaF{sub 2} Total Absorption Calorimeter, at the recently constructed neutron time-of-flight facility n-TOF at CERN in the energy range from 0.03 eV to 1 MeV. Monte-Carlo simulations with GEANT4 and MCNPX of the detector response have been performed. After the background subtraction and correction with dead time and pile-up, the capture yield from 0.03 eV up to 1.5 keV was derived. The analysis of the capture yield in terms of R-matrix resonance parameters is discussed. We have identified 123 resonances and measured the resonance parameters in the energy range from 0.03 eV to 1.5 keV. The mean radiative width <{gamma}{sub {gamma}}> is found to be (38.2 {+-} 1.5) meV and the mean spacing parameter is (11.0 {+-} 0.2) eV, both values agree well with recommended values.

  12. Measurement of the neutron capture cross section of U{sup 234} in n-TOF at CERN for Generation IV nuclear reactors; Mesure de la section efficace de capture neutronique de l'{sup 234}U a n-TOF au CERN pour les reacteurs nucleaires de generation 4

    Energy Technology Data Exchange (ETDEWEB)

    Dridi, W

    2006-11-15

    Accurate and reliable neutron capture cross sections are needed in many research areas, including stellar nucleosynthesis, advanced nuclear fuel cycles, waste transmutation, and other applied programs. In particular, the accurate knowledge of U{sup 234}(n,{gamma}) reaction cross section is required for the design and realization of nuclear power plants based on the thorium fuel cycle. We have measured the neutron capture cross section of U{sup 234}, with a 4{pi} BaF{sub 2} Total Absorption Calorimeter, at the recently constructed neutron time-of-flight facility n-TOF at CERN in the energy range from 0.03 eV to 1 MeV. Monte-Carlo simulations with GEANT4 and MCNPX of the detector response have been performed. After the background subtraction and correction with dead time and pile-up, the capture yield from 0.03 eV up to 1.5 keV was derived. The analysis of the capture yield in terms of R-matrix resonance parameters is discussed. We have identified 123 resonances and measured the resonance parameters in the energy range from 0.03 eV to 1.5 keV. The mean radiative width <{gamma}{sub {gamma}}> is found to be (38.2 {+-} 1.5) meV and the mean spacing parameter is (11.0 {+-} 0.2) eV, both values agree well with recommended values.

  13. Measurement of the {sup 232}thorium capture cross section at n-TOF-CERN; Mesure de la section efficace de capture neutronique du {sup 232}Th a n-TOF au CERN

    Energy Technology Data Exchange (ETDEWEB)

    Aerts, G

    2005-09-01

    Within the context of nuclear power as a sustainable energy resource, a program of research is concentrated on a new nuclear fuel cycle based on thorium. The main advantage, as compared to the uranium cycle, is a lower production of minor actinides, of which the radiological impact on the long term constitutes a problem. At present, nuclear data libraries don't provide cross sections of a good enough quality, allowing more realistic calculations from simulations related to these reactors. The {sup 232}Th neutron capture cross section is an example. With the n-TOF collaboration, the measurement of this reaction was achieved in 2002 using two C{sub 6}D{sub 6} detectors. The experimental area located at CERN, is characterized by an outstanding neutron energy resolution coupled to a high instantaneous neutron flux. The determination of the gamma-ray cascade detection efficiency, with a random behaviour, has been obtained by the use of weighting functions. These were deduced from Monte Carlo simulations with the code MCNP. Data extraction, reduction, and the description of the neutron flux have lead to the capture yield. In the resolved resonance region, the resonance parameters describing the cross section were deduced with the code SAMMY, using the R-matrix theory. In the unresolved resonance region, an uncertainty of 3,5% is found, and a comparison with recent measurements shows a good agreement. (author)

  14. $^7Be(n,\\alpha)^4He$ reaction and the Cosmological Lithium Problem: measurement of the cross section in a wide energy range at n_TOF (CERN)

    CERN Document Server

    Barbagallo, M.; Cosentino, L.; Maugeri, E.; Heinitz, S.; Mengoni, A.; Dressler, R.; Schumann, D.; Käppeler, F.; Colonna, N.; Finocchiaro, P.; Ayranov, M.; Damone, L.; Kivel, N.; Aberle, O.; Altstadt, S.; Andrzejewski, J.; Audouin, L.; Bacak, M.; Balibrea-Correa, J.; Barros, S.; Bécares, V.; Bečvář, F.; Beinrucker, C.; Berthoumieux, E.; Billowes, J.; Bosnar, D.; Brugger, M.; Caamaño, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Cardella, R.; Casanovas, A.; Castelluccio, D. M.; Cerutti, F.; Chen, Y. H.; Chiaveri, E.; Cortés, G.; Cortés-Giraldo, M. A.; Cristallo, S.; Diakaki, M.; Domingo-Pardo, C.; Dupont, E.; Duran, I.; Fernandez-Dominguez, B.; Ferrari, A.; Ferreira, P.; Furman, W.; Ganesan, S.; García-Rios, A.; Gawlik, A.; Glodariu, T.; Göbel, K.; Gonçalves, I. F.; González-Romero, E.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Harada, H.; Heftrich, T.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Katabuchi, T.; Kavrigin, P.; Kimura, A.; Kokkoris, M.; Krtička, M.; Leal-Cidoncha, E.; Lerendegui, J.; Lederer, C.; Leeb, H.; Lo Meo, S.; Lonsdale, S. J.; Losito, R.; Macina, D.; Marganiec, J.; Martínez, T.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Mazzone, A.; Mendoza, E.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Montesano, S.; Nolte, R.; Oprea, A.; Pappalardo, A.; Patronis, N.; Pavlik, A.; Perkowski, J.; Piscopo, M.; Plompen, A.; Porras, I.; Praena, J.; Quesada, J.; Rajeev, K.; Rauscher, T.; Reifarth, R.; Riego-Perez, A.; Rout, P.; Rubbia, C.; Ryan, J.; Sabate-Gilarte, M.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Sedyshev, P.; Smith, A. G.; Stamatopoulos, A.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vlachoudis, V.; Vlastou, R.; Vollaire, J.; Wallner, A.; Warren, S.; Weigand, M.; Weiß, C.; Wolf, C.; Woods, P. J.; Wright, T.; Žugec, P.

    2016-01-01

    The energy-dependent cross section of the 7Be(n,alpha)4He reaction, of interest for the so-called Cosmological Lithium Problem in Big Bang Nucleosynthesis, has been measured for the first time from 10 meV to 10 keV neutron energy. The challenges posed by the short half-life of 7Be and by the low reaction cross section have been overcome at n_TOF thanks to an unprecedented combination of the extremely high luminosity and good resolution of the neutron beam in the new experimental area (EAR2) of the n_TOF facility at CERN, the availability of a sufficient amount of chemically pure 7Be, and a specifically designed experimental setup. Coincidences between the two alpha-particles have been recorded in two Si-7Be-Si arrays placed directly in the neutron beam. The present results are consistent, at thermal neutron energy, with the only previous measurement performed in the 60's at a nuclear reactor. The energy dependence here reported clearly indicates the inadequacy of the cross section estimates currently used in ...

  15. Radiative neutron capture on 242Pu in the resonance region at the CERN n_TOF-EAR1 facility

    Science.gov (United States)

    Lerendegui-Marco, J.; Guerrero, C.; Mendoza, E.; Quesada, J. M.; Eberhardt, K.; Junghans, A. R.; Krtička, M.; Aberle, O.; Andrzejewski, J.; Audouin, L.; Bécares, V.; Bacak, M.; Balibrea, J.; Barbagallo, M.; Barros, S.; Bečvář, F.; Beinrucker, C.; Berthoumieux, E.; Billowes, J.; Bosnar, D.; Brugger, M.; Caamaño, M.; Calviño, F.; Calviani, M.; Cano-Ott, D.; Cardella, R.; Casanovas, A.; Castelluccio, D. M.; Cerutti, F.; Chen, Y. H.; Chiaveri, E.; Colonna, N.; Cortés, G.; Cortés-Giraldo, M. A.; Cosentino, L.; Damone, L. A.; Diakaki, M.; Dietz, M.; Domingo-Pardo, C.; Dressler, R.; Dupont, E.; Durán, I.; Fernández-Domínguez, B.; Ferrari, A.; Ferreira, P.; Finocchiaro, P.; Furman, V.; Göbel, K.; García, A. R.; Gawlik, A.; Glodariu, T.; Gonçalves, I. F.; González-Romero, E.; Goverdovski, A.; Griesmayer, E.; Gunsing, F.; Harada, H.; Heftrich, T.; Heinitz, S.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Katabuchi, T.; Kavrigin, P.; Ketlerov, V.; Khryachkov, V.; Kimura, A.; Kivel, N.; Kokkoris, M.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Lo Meo, S.; Lonsdale, S. J.; Losito, R.; Macina, D.; Marganiec, J.; Martínez, T.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Matteucci, F.; Maugeri, E. A.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Mirea, M.; Montesano, S.; Musumarra, A.; Nolte, R.; Oprea, A.; Patronis, N.; Pavlik, A.; Perkowski, J.; Porras, J. I.; Praena, J.; Rajeev, K.; Rauscher, T.; Reifarth, R.; Riego-Perez, A.; Rout, P. C.; Rubbia, C.; Ryan, J. A.; Sabaté-Gilarte, M.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Sedyshev, P.; Smith, A. G.; Stamatopoulos, A.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Warren, S.; Weigand, M.; Weiss, C.; Wolf, C.; Woods, P. J.; Wright, T.; Žugec, P.; n TOF Collaboration

    2018-02-01

    The spent fuel of current nuclear reactors contains fissile plutonium isotopes that can be combined with uranium to make mixed oxide (MOX) fuel. In this way the Pu from spent fuel is used in a new reactor cycle, contributing to the long-term sustainability of nuclear energy. However, an extensive use of MOX fuels, in particular in fast reactors, requires more accurate capture and fission cross sections for some Pu isotopes. In the case of 242Pu there are sizable discrepancies among the existing capture cross-section measurements included in the evaluations (all from the 1970s) resulting in an uncertainty as high as 35% in the fast energy region. Moreover, postirradiation experiments evaluated with JEFF-3.1 indicate an overestimation of 14% in the capture cross section in the fast neutron energy region. In this context, the Nuclear Energy Agency (NEA) requested an accuracy of 8% in this cross section in the energy region between 500 meV and 500 keV. This paper presents a new time-of-flight capture measurement on 242Pu carried out at n_TOF-EAR1 (CERN), focusing on the analysis and statistical properties of the resonance region, below 4 keV. The 242Pu(n ,γ ) reaction on a sample containing 95(4) mg enriched to 99.959% was measured with an array of four C6D6 detectors and applying the total energy detection technique. The high neutron energy resolution of n_TOF-EAR1 and the good statistics accumulated have allowed us to extend the resonance analysis up to 4 keV, obtaining new individual and average resonance parameters from a capture cross section featuring a systematic uncertainty of 5%, fulfilling the request of the NEA.

  16. Experimental setup and procedure for the measurement of the {sup 7}Be(n,α)α reaction at n-TOF

    Energy Technology Data Exchange (ETDEWEB)

    Cosentino, L. [INFN Laboratori Nazionali del Sud, Catania (Italy); Musumarra, A. [INFN Laboratori Nazionali del Sud, Catania (Italy); Dipartimento di Fisica e Astronomia DFA, Università di Catania (Italy); Barbagallo, M. [INFN Sezione di Bari (Italy); Pappalardo, A. [INFN Laboratori Nazionali del Sud, Catania (Italy); Colonna, N.; Damone, L. [INFN Sezione di Bari (Italy); Piscopo, M. [INFN Laboratori Nazionali del Sud, Catania (Italy); Finocchiaro, P., E-mail: FINOCCHIARO@LNS.INFN.IT [INFN Laboratori Nazionali del Sud, Catania (Italy); Maugeri, E.; Heinitz, S.; Schumann, D.; Dressler, R.; Kivel, N. [Paul Scherrer Institut, Nuclear Energy and Safety Research Department, 5232 Villigen (Switzerland); Aberle, O. [CERN, Geneva (Switzerland); Andrzejewski, J. [Uniwersytet Łódzki, Lodz (Poland); Audouin, L. [Institut de Physique Nucléaire, CNRS-IN2P3, Univ. Paris-Sud, Université Paris-Saclay, 91406 Orsay Cedex (France); Ayranov, M. [European Commission, DG-Energy (Luxembourg); Bacak, M. [Atominstitut der Österreichischen Universitäten, Technische Universität Wien (Austria); Barros, S. [C2TN-Instituto Superior Tecníco, Universidade de Lisboa (Portugal); Balibrea-Correa, J. [Centro de Investigaciones Energeticas Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain); and others

    2016-09-11

    The newly built second experimental area EAR2 of the n-TOF spallation neutron source at CERN allows to perform (n, charged particles) experiments on short-lived highly radioactive targets. This paper describes a detection apparatus and the experimental procedure for the determination of the cross-section of the {sup 7}Be(n,α)α reaction, which represents one of the focal points toward the solution of the cosmological Lithium abundance problem, and whose only measurement, at thermal energy, dates back to 1963. The apparently unsurmountable experimental difficulties stemming from the huge {sup 7}Be γ-activity, along with the lack of a suitable neutron beam facility, had so far prevented further measurements. The detection system is subject to considerable radiation damage, but is capable of disentangling the rare reaction signals from the very high background. This newly developed setup could likely be useful also to study other challenging reactions requiring the detectors to be installed directly in the neutron beam.

  17. Neutron capture cross section measurement of $^{238}$U at the n_TOF CERN facility in the energy region from 1 eV to 700 keV

    CERN Document Server

    Mingrone, F; Vannini, G; Colonna, N; Gunsing, F; Zugec, P; Altstadt, S; Andrzejewski, J; Audouin, L; Barbagallo, M; Becares, V; Becvavr, F; Belloni, F; Berthoumieux, E; Billowes, J; Bosnar, D; Brugger, M; Calviani, M; Calvino, F; Cano-Ott, D; Carrapico, C; Cerutti, F; Chiaveri, E; Chin, M; Cortes, G; Cortes-Giraldo, M A; Diakaki, M; Domingo-Pardo, C; Duran, I; Dressler, R; Eleftheriadis, C; Ferrari, A; Fraval, K; Ganesan, S; Garcia, A R; Giubrone, G; Goncalves, I F; Gonzalez-Romero, E; Griesmayer, E; Guerrero, C; Hernandez-Prieto, A; Jenkins, D G; Jericha, E; Kadi, Y; Kappeler, F; Karadimos, D; Kivel, N; Koehler, P; Kokkoris, M; Krticka, M; Kroll, J; Lampoudis, C; Langer, C; Leal-Cidoncha, E; Lederer, C; Leeb, H; Leong, L S; Lo Meo, S; Losito, R; Mallick, A; Manousos, A; Marganiec, J; Martinez, T; Mastinu, P F; Mastromarco, M; Mendoza, E; Mengoni, A; Milazzo, P M; Mirea Horia, M; Mondalaers, W; Paradela, C; Pavlik, A; Perkowski, J; Plompen, A; Praena, J; Quesada, J M; Rauscher, T; Reifarth, R; Riego, A; Robles, M S; Rubbia, C; Sabate-Gilarte, M; Sarmento, R; Saxena, A; Schillebeeckx, P; Schmidt, S; Schumann, D; Tagliente, G; LTain, J; Tarrio, D; Tassan-Got, L; Tsinganis, A; Valenta, S; Variale, V; Vaz, P; Ventura, A; Vermeulen, M J; Vlachoudis, V; Vlastou, R; Wallner, A; Ware, T; Weigand, M; Weiss, C; Wright, T

    2016-01-01

    The aim of this work is to provide a precise and accurate measurement of the $^{238}$U(n,$\\gamma$) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behaviour of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross-section of $^{238}$U should be further reduced to 1-3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were pr...

  18. Neutron Capture Measuremetns on Minor Actinides at the n_TOF Facility at CERN: Past, Present and Future

    CERN Document Server

    Cano-Ott, D; Eleftheriadis, C; Leeb, H; Calvino, F; Herrera-Martinez, A; Savvidis, I; Vlachoudis, V; Haas, B; Abbondanno, U; Vannini, G; Oshima, M; Gramegna, F; Wiescher, M; Pigni, M T; Wiendler, H; Mengoni, A; Quesada, J; Becvar, F; Rosetti, M; Cennini, P; Mosconi, M; Duran, I; Rauscher, T; Ketlerov, V; Couture, A; Capote, R; Sarchiapone, L; Vlastou, R; Domingo-Pardo, C; Pavlopoulos, P; Karamanis, D; Krticka, M; Griesmayer, E; Jericha, E; Ferrari, A; Martinez, T; Oberhummer, H; Karadimos, D; Plompen, A; Mendoza, E; Terlizzi, R; Cortes, G; Cox, J; Voss, F; Pretel, C; Colonna, N; Berthoumieux, E; Dolfini, R; Vaz, P; Heil, M; Lopes, I; Lampoudis, C; Walter, S; Calviani, M; Gonzalez-Romero, E; Stephan, C; Tain, J L; Belloni, F; Igashira, M; Papachristodoulou, C; Aerts, G; Tavora, L; Milazzo, P M; Rudolf, G; Andrzejewski, J; Villamarin, D; Ferreira-Marques, R; Meaze, M H; O'Brien, S; Gunsing, F; Reifarth, R; Perrot, L; Lindote, A; Neves, F; Poch, A; Konovalov, V; Kerveno, M; Marques, L; Rubbia, C; Koehler, P; Dahlfors, M; Wisshak, K; Fujii, K; De Albornoz, A C; Salgado, J; Dridi, W; Ventura, A; Andriamonje, S; Dillman, I; Assimakopoulos, P; Ferrant, L; Lozano, M; Patronis, N; Chiaveri, E; Guerrero, C; Kadi, Y; Vicente, M C; Praena, J; Baumann, P; Moreau, C; Kappeler, F; Rullhusen, P; Furman, W; David, S; Marrone, S; Paradela, C; Audouin, L; Tassan-Got, L; Alvarez-Velarde, F; Massimi, C; Mastinu, P; Isaev, S; Pancin, J; Papadopoulos, C; Tagliente, G; Alvarez, H; Haight, R; Goverdovski, A; Chepel, V; Plag, R; Kossionides, E; Badurek, G; Marganiec, J; Lukic, S; Frais-Koelbl, H; Pavlik, A; Goncalves, I

    2011-01-01

    The successful development of advanced nuclear systems for sustainable energy production and nuclear waste management depends on high quality nuclear data libraries. Recent sensitivity studies and reports {[}1-3] have identified the need for substantially improving the accuracy of neutron cross-section data for minor actinides. The n\\_TOF collaboration has initiated an ambitious experimental program for the measurement of neutron capture cross sections of minor actinides. Two experimental setups have been constructed for this purpose: a Total Absorption Calorimeter (TAC) {[}4] for measuring neutron capture cross-sections of low-mass and/or radioactive samples and a set of two low neutron sensitivity C(6)D(6) detectors for the less radioactive materials.

  19. Measurement of the fission cross-section of $^{240}$Pu and $^{242}$Pu at CERN's n_TOF Facility

    CERN Multimedia

    Pavlik, A F; Gonzalez romero, E M

    The n_TOF Collaboration proposes to continue the fission program, already started in 2002-2004, taking advantage of the newly constructed Work Sector Type A, with the measurement of the two isotopes : $^{240}$ Pu and $^{242}$ Pu. They are both of major importance for reactor physics applications and are included in the Nuclear Energy Agency (NEA) High Priority List [1], in the NEA WPEC Subgroup 26 Report on the accuracy of nuclear data for advanced reactor designe [2] and in the EU 6$^{th}$ Framework Programme IP-EUROTRANS/NUDATRA reports [3]. Based on those requests, the measurement of the fission cross-section of the two Pu isotopes is one of the objectives of the project ANDES of the FP7 EURATOM program [4].

  20. Measurement of the angular distribution of fission fragments using a PPAC assembly at CERN n{sub T}OF

    Energy Technology Data Exchange (ETDEWEB)

    Tarrío, D., E-mail: dtarriov@gmail.com [Universidade de Santiago de Compostela (Spain); Leong, L.S.; Audouin, L. [Centre National de la Recherche Scientifique/IN2P3 -Université Paris-Sud - IPN, Orsay (France); Duran, I.; Paradela, C. [Universidade de Santiago de Compostela (Spain); Tassan-Got, L.; Le Naour, C.; Bacri, C.O.; Petitbon, V.; Mottier, J. [Centre National de la Recherche Scientifique/IN2P3 -Université Paris-Sud - IPN, Orsay (France); Caamaño, M. [Universidade de Santiago de Compostela (Spain); Altstadt, S. [Johann-Wolfgang-Goethe Universität, Frankfurt (Germany); Andrzejewski, J. [Uniwersytet Łódzki, Lodz (Poland); Barbagallo, M. [Istituto Nazionale di Fisica Nucleare, Bari (Italy); Bécares, V. [Centro de Investigaciones Energeticas Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain); Bečvář, F. [Charles University, Prague (Czech Republic); Belloni, F. [Commissariat à l’Énergie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Berthoumieux, E. [Commissariat à l’Énergie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Billowes, J. [University of Manchester, Oxford Road, Manchester (United Kingdom); Boccone, V. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); and others

    2014-04-11

    A fission reaction chamber based on Parallel Plate Avalanche Counters (PPACs) was built for measuring angular distributions of fragments emitted in neutron-induced fission of actinides at the neutron beam available at the Neutron Time-Of-Flight (n{sub T}OF) facility at CERN. The detectors and the samples were tilted 45° with respect to the neutron beam direction to cover all the possible values of the emission angle of the fission fragments. The main features of this setup are discussed and results on the fission fragment angular distribution are provided for the {sup 232}Th(n,f) reaction around the fission threshold. The results are compared with the available data in the literature, demonstrating the good capabilities of this setup.

  1. Neutron cross-sections for advanced nuclear systems: the n_TOF project at CERN

    Directory of Open Access Journals (Sweden)

    Barbagallo M.

    2014-01-01

    Full Text Available The study of neutron-induced reactions is of high relevance in a wide variety of fields, ranging from stellar nucleosynthesis and fundamental nuclear physics to applications of nuclear technology. In nuclear energy, high accuracy neutron data are needed for the development of Generation IV fast reactors and accelerator driven systems, these last aimed specifically at nuclear waste incineration, as well as for research on innovative fuel cycles. In this context, a high luminosity Neutron Time Of Flight facility, n_TOF, is operating at CERN since more than a decade, with the aim of providing new, high accuracy and high resolution neutron cross-sections. Thanks to the features of the neutron beam, a rich experimental program relevant to nuclear technology has been carried out so far. The program will be further expanded in the near future, thanks in particular to a new high-flux experimental area, now under construction.

  2. Aplicación de la Espectrometría de Masas Maldi tof/tof a la Endocrinología, Inmunología y Patología del paiche Arapaima gigas

    OpenAIRE

    Cueva Távara, Mario David

    2016-01-01

    RESUMEN El pez amazónico gigante “paiche” Arapaima gigas es una especie prometedora para la piscicultura tropical debido a sus características anatómicas, sin embargo, su completa domesticación es problemática debido a la falta de información biológica. Los progresos recientes en el campo de la biotecnología molecular, llamados “omicas”, están revolucionando la ictiología básica y aplicada; en particular la proteómica por espectrometría doble masa MALDI TOF/TOF, que permite la detección...

  3. Integral measurements of lattice properties in the natural uranium-graphite critical facility Marius; Mesures globales de reseaux a graphite dans l'empilement critique marius

    Energy Technology Data Exchange (ETDEWEB)

    Cogne, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    A systematic study of natural uranium-graphite lattices has been undertaken in the critical facility MARIUS, which was built in 1959 in Marcoule. Integral measurement of lattice properties are carried out by the progressive replacement method. This report describes the experimental methods, the analysis of the experiments and the results obtained for lattices with pitches ranging from 192 to 317 mm and fuel elements with cross sections ranging from 6 to 20 cm{sup 2}. The principles of correlation of the results are also outlined. Additional experimental results are also given, pertaining to the determination of the anisotropy, of both the axial and the radial migration areas, and of the age in graphite. (author) [French] L'empilement critique MARIUS, construit en 1959 a Marcoule, a ete utilise pour l'etude systematique des reseaux a graphite-uranium naturel. Les mesures globales de reseaux sont faites par la methode de remplacement progressif. On decrit ici les methodes experimentales utilisees pour ces mesures globales, les principes du depouillement et les resultats obtenus pour des pas de 192 a 317 mm et des combustibles de 6 a 20 cm{sup 2} d'uranium naturel. On donne d'autre part le principe de correlation des mesures. Un certain nombre de resultats experimentaux complementaires sont donnes, en permettant de determiner l'anisotropie, les aires de migration axiale et radiale, l'age dans le graphite. (auteur)

  4. PHENIX Fast TOF

    Energy Technology Data Exchange (ETDEWEB)

    Soha, Aria [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Chiu, Mickey [Brookhaven National Lab. (BNL), Upton, NY (United States); Mannel, Eric [Brookhaven National Lab. (BNL), Upton, NY (United States); Stoll, Sean [Brookhaven National Lab. (BNL), Upton, NY (United States); Lynch, Don [Brookhaven National Lab. (BNL), Upton, NY (United States); Boose, Steve [Brookhaven National Lab. (BNL), Upton, NY (United States); Northacker, Dave [Brookhaven National Lab. (BNL), Upton, NY (United States); Alfred, Marcus [Howard Univ., Washington, DC (United States); Lindesay, James [Howard Univ., Washington, DC (United States); Chujo, Tatsuya [Univ. of Tsukuba (Japan); Inaba, Motoi [Univ. of Tsukuba (Japan); Nonaka, Toshihiro [Univ. of Tsukuba (Japan); Sato, Wataru [Univ. of Tsukuba (Japan); Sakatani, Ikumi [Univ. of Tsukuba (Japan); Hirano, Masahiro [Univ. of Tsukuba (Japan); Choi, Ihnjea [Univ. of Illinois, Urbana-Champaign, IL (United States)

    2014-01-15

    This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) and the experimenters of PHENIX Fast TOF group who have committed to participate in beam tests to be carried out during the FY2014 Fermilab Test Beam Facility program. The goals for this test beam experiment are to verify the timing performance of the two types of time-of-flight detector prototypes.

  5. Utilidad de la espectrometría de masas MALDI-TOF en la identificación de bacterias anaerobias

    Directory of Open Access Journals (Sweden)

    Mariela S Zárate

    Full Text Available El análisis de espectrometría de masas mediante la metodología hoy conocida como MALDI-TOF MS (Matrix-assited laser desorption/ionization time-of-flight mass spectrometry se ha convertido en un recurso de referencia para la identificación de microorganismos en microbiología clínica. No obstante, los datos relativos a algunos grupos de microorganismos son todavía controvertidos. El objetivo del presente estudio fue determinar la utilidad del MALDI-TOF MS para la identificación de aislamientos clínicos de bacterias anaerobias. Se analizaron 106 aislamientos de bacterias anaerobias mediante MALDI-TOF MS y por pruebas bioquímicas convencionales. En aquellos casos en los que la identificación por metodología convencional no era aplicable o frente a una discordancia de resultados entre las metodologías citadas, se realizó la secuenciación del gen 16S del ARNr. El método convencional y el MALDI-TOF MS coincidieron a nivel de género y especie en un 95,3 % de los casos considerando la totalidad de los aislamientos estudiados. Al considerar solo el conjunto de los bacilos gram negativos, la coincidencia fue del 91,4 %; entre los bacilos gram positivos, fue del 100 %; los 8 aislados de cocos gram positivos estudiados coincidieron y también hubo coincidencia en el único coco gram negativo incluido. Los datos obtenidos en este estudio demuestran que el MALDI-TOF MS ofrece la posibilidad de llegar a una adecuada identificación de bacterias anaerobias.

  6. Determination of the Neutron Fluence, the Beam Characteristics and the Backgrounds at the CERN-PS TOF Facility

    CERN Multimedia

    Leal, L C; Kitis, G; Guber, K H; Quaranta, A; Koehler, P E

    2002-01-01

    In the scope of our programme we propose to start in July 2000 with measurements on elements of well known cross sections, in order to check the reliability of the whole experimental installation at the CERN-TOF facility. These initial exploratory measurements will provide the key-parameters required for the further experimentation at the CERN-TOF neutron beam. The neutron fluence and energy resolution will be determined as a function of the neutron kinetic energy by reproducing standard capture and fission cross sections. The measurements of capture cross sections on elements with specific cross section features will allow to us to disentangle the different components of backgrounds and estimate their level in the experimental area. The time-energy calibration will be determined and monitored with a set of monoenergetic filters as well as by the measurements of elements with resonance-dominated cross sections. Finally, in this initial phase the behaviour of several detectors scheduled in successive measureme...

  7. Les mesures de métrologie pour le CLIC

    CERN Document Server

    Cherif, A

    2008-01-01

    Le projet CLIC est en tout point un défi technique majeur ; c?est le cas également pour la mesure dimensionnelle. Quels sont les équipements et les méthodes qui permettent de caractériser les pièces avec une incertitude de mesure aussi réduite que possible, vu les tolérances micrométriques imposées ? Afin de répondre à cette question, une veille technologique a été maintenue sur une longue période. Les acteurs relevants ont été contactés pour bénéficier d?une ouverture sur les dernières avancées dans le domaine. Différentes techniques ont été étudiées et comparées telles que la digitalisation, la tomographie X, la mesure tridimensionnelle. L'assemblage de haute précision des composants est aussi primordial. Sa mise en ?uvre sous un microscope optique ou à l'aide d'une machine tridimensionnelle est en cours d?étude. L'exposé traitera aussi de la mesure de rugosité, un domaine où nous disposons de moyens adaptés aux exigences spécifiques du projet.

  8. Measurement of fission cross-section of actinides at n_TOF for advanced nuclear reactors

    CERN Document Server

    Calviani, Marco; Montagnoli, G; Mastinu, P

    2009-01-01

    The subject of this thesis is the determination of high accuracy neutron-induced fission cross-sections of various isotopes - all of which radioactive - of interest for emerging nuclear technologies. The measurements had been performed at the CERN neutron time-of-flight facility n TOF. In particular, in this work, fission cross-sections on 233U, the main fissile isotope of the Th/U fuel cycle, and on the minor actinides 241Am, 243Am and 245Cm have been analyzed. Data on these isotopes are requested for the feasibility study of innovative nuclear systems (ADS and Generation IV reactors) currently being considered for energy production and radioactive waste transmutation. The measurements have been performed with a high performance Fast Ionization Chamber (FIC), in conjunction with an innovative data acquisition system based on Flash-ADCs. The first step in the analysis has been the reconstruction of the digitized signals, in order to extract the information required for the discrimination between fission fragm...

  9. Site-specific glycoprofiling of N-linked glycopeptides using MALDI-TOF MS: strong correlation between signal strength and glycoform quantities

    DEFF Research Database (Denmark)

    Thaysen-Andersen, Morten; Mysling, Simon; Højrup, Peter

    2009-01-01

    Site-specific glycoprofiling of N-linked glycopeptides using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an emerging technique, but its quantitative accuracy lacks documentation. Thus, a systematic study of widely different glycopeptides was perf......Site-specific glycoprofiling of N-linked glycopeptides using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an emerging technique, but its quantitative accuracy lacks documentation. Thus, a systematic study of widely different glycopeptides...... was performed to determine the relationship between the relative abundances of the individual glycoforms and the MALDI-TOF MS signal strength. Glycopeptides derived from glycoproteins containing neutral glycans (ribonuclease B, IgG, and ovalbumin) were initially profiled and yielded excellent and reproducible...... quantitation (correlation coefficient r = 0.9958, n = 5) when evaluated against a normal phase HPLC 2-AB glycan profile. Similarly, precise quantitation was observed for various forms of N-glycans (free, permethylated, and fluorescence-labeled) using MS. In addition, three different sialoglycopeptides from...

  10. La mesure comme représentation de l’objet

    Directory of Open Access Journals (Sweden)

    Danielle Laberge

    2011-04-01

    Full Text Available Adoptant une perspective d’interpénétration des méthodes et nous centrant sur le rôle des actes méthodiques dans la production des connaissances, nous procédons à l’examen de la place et du rôle de l’interprétation dans le processus de la mesure. Partant de la définition d’Abraham Kaplan selon laquelle « la mesure est l’assignation de nombres à des objets, des événements ou des situations à partir d’un système de règles définissant des propriétés pouvant être quantifiées » (Kaplan, 1964, nous considérons la mesure comme une activité méthodique de recherche constituée d’un ensemble d’actes interprétatifs distincts, mis en œuvre à des moments divers du processus de recherche. Nous montrons que la mesure est susceptible à la fois de réduire la complexité et de la restaurer. La mesure ne peut être limitée à sa dimension quantitative. Elle se construit dans l’interrelation permanente avec les autres actes de connaissance.Measurement process as object’s representation. Analysis and interpretationIn this article we examine the status and the role of interpretation in the measurement process, from the point of view of mixed methods. Starting with Abraham Kaplan’s definition of “measurement as the assignment of numbers to objects (or events or situations in accord with some rule defining properties that can be quantified”, we state that measurement is produced through a set of different interpretations at various moments during the research process. It cannot be seen only as a reduction of complexity and a quantification of reality since it is also a way of restoring complexity and quality. Measurement must be understood in relation with all the other knowledge operations.La medida como objeto de representaciones. Análisis e interpretaciónEn este artículo examínanos el estatuto y el papel de los métodos de medida desde el punto de vista de lo que constituye un acto metódico. A partir

  11. A new CVD diamond mosaic-detector for (n, α) cross-section measurements at the n{sub T}OF experiment at CERN

    Energy Technology Data Exchange (ETDEWEB)

    Weiß, C., E-mail: christina.weiss@cern.ch [Atominstitut, Technische Universität Wien (Austria); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Griesmayer, E. [Atominstitut, Technische Universität Wien (Austria); Guerrero, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Altstadt, S. [Johann-Wolfgang-Goethe Universität, Frankfurt (Germany); Andrzejewski, J. [Uniwersytet Łódzki, Lodz (Poland); Audouin, L. [Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay (France); Badurek, G. [Atominstitut, Technische Universität Wien (Austria); Barbagallo, M. [Istituto Nazionale di Fisica Nucleare, Bari (Italy); Bécares, V. [Centro de Investigaciones Energeticas Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain); Bečvář, F. [Charles University, Prague (Czech Republic); Belloni, F. [Commissariat à l’Énergie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); Berthoumieux, E. [Commissariat à l’Énergie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette (France); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Billowes, J. [University of Manchester, Oxford Road, Manchester (United Kingdom); Boccone, V. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Bosnar, D. [Department of Physics, Faculty of Science, University of Zagreb (Croatia); Brugger, M.; Calviani, M. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Calviño, F. [Universitat Politecnica de Catalunya, Barcelona (Spain); and others

    2013-12-21

    At the n{sub T}OF experiment at CERN a dedicated single-crystal chemical vapor deposition (sCVD) Diamond Mosaic-Detector has been developed for (n,α) cross-section measurements. The detector, characterized by an excellent time and energy resolution, consists of an array of 9 sCVD diamond diodes. The detector has been characterized and a cross-section measurement has been performed for the {sup 59}Ni(n,α){sup 56}Fe reaction in 2012. The characteristics of the detector, its performance and the promising preliminary results of the experiment are presented. -- Highlights: •A large-area detector of 3 ×3 sCVD diamonds was built for (n, α) measurements. •The {sup 59}Ni(n, α){sup 56}Fe cross-section was measured successfully at n{sub T}OF/CERN. •The energy resolution of the detector meets the expectations from simulations. •The reaction products during the measurement at n{sub T}OF could clearly be separated. •The detector is suitable for (n, α) measurements in a heterogeneous beam.

  12. A new BPM-TOF system for CologneAMS

    Energy Technology Data Exchange (ETDEWEB)

    Pascovici, Gheorghe; Dewald, Alfred; Heinze, Stefan; Schiffer, Markus; Feuerstein, Mark [CologneAMS, Universitaet Koeln (Germany); Pfeiffer, Michael; Jolie, Jan; Zell, Karl Oskar [IKP, Universitaet Koeln (Germany); Blanckenburg, Friedhelm von [GFZ, Potsdam (Germany)

    2011-07-01

    At the center for accelerator mass spectrometry (CologneAMS) a complex beam detector consisting of a high resolution Beam Profile Monitor (BPM) and a Time of Flight (TOF) spectrometer with tracking capabilities was designed especially for the needs of the Cologne AMS facility. The complex beam detector assembly is designed to match the beam specifications of the 6MV Tandetron AMS setup and its DAQ system, which is presently in the commissioning phase at the IKP of the University of Cologne. The BPM-TOF system will have a reconfigurable structure, namely: either a very fast TOF subsystem with a small active area or a more complex BPM -TOF detector with beam tracking capabilities and with a large active area. The systems aims for background suppression in case of the spectrometry of heavy ions, e.g. U, Cm, Pu, Am etc. and could also be used as an additional filter e.g., for the isobar {sup 36}S in case of the spectrometry of {sup 36}Cl.

  13. TOF-PET/MR和TOF-PET/CT在体部恶性肿瘤SUVmax值的比较%Comparision of SUVmax of TOF-PET/MR and TOF-PET/CT in body malignant tumor

    Institute of Scientific and Technical Information of China (English)

    宋天彬; 卢洁; 崔碧霄; 马杰; 杨宏伟; 马蕾; 梁志刚

    2017-01-01

    目的 探讨时间飞行(TOF)技术PET/CT和PET/MR检查体部恶性病变SUVmax值的一致性.方法 回顾性分析接受TOF-PET/CT和TOF-PET/MR检查的体部恶性肿瘤患者20例,分为先PET/CT后PET/MR组和先PET/MR后PET/CT组,每组10例.采用Bland-Altma图评价两次检查病灶SUVmax值的一致性,采用多因素方差分析评价扫描顺序和机器类型对病灶的SUVmax测量值的影响.结果 TOF-PET/CT与TOF-PET/MR检查病灶的SUVmax值有较好的一致性[先PET/CT后PET/MR组:均值差为3.06,95%CI(-7.5,13.6),先PET/MR后PET/CT组:均值差3.0,95%CI(-2.4,8.3)].扫描顺序对于恶性病灶的SUVmax有影响(F=46.00,P<0.001),而机器类型对恶性病灶的SUVmax值无影响(F=0.005,P=0.95).结论 TOF-PET/MR和TOF-PET/CT在体部恶性病变SUVmax值测量方面具有相当的诊断价值,且延迟显像SUVmax的增加与采集时间有关,而与检查机器类型无关.%Objective To explore the consistency of time-of-flight (TOF) technology of PET/MRI and PET/CT for max standardized uptake value (SUVmax) of body malignant tumors.Methods A retrospective analysis of TOF-PET/CT and TOF-PET/MR imaging data about twenty patients with body malignant tumors was performed.Patients were divided into two groups (each n=10),including PET/CT first and sequentially PET/MR group and PET/MR first and sequentially PET/CT group.Bland-Altman figure was used to evaluate consistency of SUVmax of malignant lesions between TOF-PET/CT and TOF-PET/MR.Multi-way ANOVA was used to analysis effect of machine type and exam order on SUVmaxof malignant lesions in TOF-PET/CT and TOF-PET/MR.Results SUVmax of malignant lesions in TOF-PET/CT and TOF-PET/MR had good consistency in two groups (PET/CT first and sequentially PET/MR group:Mean difference was 3.06,95%CI was [-7.5,13.6];PET/MR first and sequentially PET/CT group:Mean difference was 3.0,95%CI was [-2.4,8.3]).SUVmax was not influenced by machine type (F=0.005,P=0.95),but exam order (F=46.00,P<0

  14. Accelerated time-of-flight (TOF) PET image reconstruction using TOF bin subsetization and TOF weighting matrix pre-computation

    International Nuclear Information System (INIS)

    Mehranian, Abolfazl; Kotasidis, Fotis; Zaidi, Habib

    2016-01-01

    Time-of-flight (TOF) positron emission tomography (PET) technology has recently regained popularity in clinical PET studies for improving image quality and lesion detectability. Using TOF information, the spatial location of annihilation events is confined to a number of image voxels along each line of response, thereby the cross-dependencies of image voxels are reduced, which in turns results in improved signal-to-noise ratio and convergence rate. In this work, we propose a novel approach to further improve the convergence of the expectation maximization (EM)-based TOF PET image reconstruction algorithm through subsetization of emission data over TOF bins as well as azimuthal bins. Given the prevalence of TOF PET, we elaborated the practical and efficient implementation of TOF PET image reconstruction through the pre-computation of TOF weighting coefficients while exploiting the same in-plane and axial symmetries used in pre-computation of geometric system matrix. In the proposed subsetization approach, TOF PET data were partitioned into a number of interleaved TOF subsets, with the aim of reducing the spatial coupling of TOF bins and therefore to improve the convergence of the standard maximum likelihood expectation maximization (MLEM) and ordered subsets EM (OSEM) algorithms. The comparison of on-the-fly and pre-computed TOF projections showed that the pre-computation of the TOF weighting coefficients can considerably reduce the computation time of TOF PET image reconstruction. The convergence rate and bias-variance performance of the proposed TOF subsetization scheme were evaluated using simulated, experimental phantom and clinical studies. Simulations demonstrated that as the number of TOF subsets is increased, the convergence rate of MLEM and OSEM algorithms is improved. It was also found that for the same computation time, the proposed subsetization gives rise to further convergence. The bias-variance analysis of the experimental NEMA phantom and a clinical

  15. The\tutility\tof\tneuroimaging\tin\tthe\tmanagement\tof\tdementia

    Directory of Open Access Journals (Sweden)

    Uduak\tE\tWilliams

    2015-10-01

    Full Text Available Dementia is a syndrome of progressive dysfunction of two or more cognitive\tdomains\tassociated\twith\timpairment\tof\tactivities\tof\tdaily\tliving. An understanding of the pathophysiology of dementia and its early diagnosis\tis\timportant\tin\tthe\tpursuit\tof\tpossible\tdisease\tmodifying\ttherapy for\tdementia.\tNeuroimaging\thas\tgreatly\ttransformed\tthis\tfield\tof\tresearch as its function has changed from a mere tool for diagnosing treatable causes of dementia to an instrument for pre-symptomatic diagnosis of dementia. This\treview\tfocuses\ton\tthe\tdiagnostic\tutility\tof\tneuroimaging\tin the\tmanagement\tof\tprogressive\tdementias.\tStructural\timaging\ttechniques like computerized tomography scan and magnetic resonance imaging highlights the anatomical, structural and volumetric details of the brain; while functional imaging techniques such as positron emission tomography, arterial spin labeling, single photon emission computerized tomography\tand\tblood\toxygen\tlevel-dependent\tfunctional\tmagnetic\tresonance\timaging\tfocuses\ton\tchemistry, circulatory\tstatus\tand\tphysiology\tof\tthe\tdifferent\tbrain\tstructures\tand\tregions.

  16. Neutron-induced fission fragment angular distribution at CERN n TOF: The Th-232 case

    CERN Document Server

    Tarrio, Diego; Paradela, Carlos

    This thesis work was done in the frame of the study of the neutron-induced fission of actinides and subactinides at the CERN n TOF facility using a fast Parallel Plate Avalanche Counters (PPACs) setup. This experimental setup provide us with an intense neutron beam with a white spectrum from thermal to 1 GeV and with an outstanding high resolution provided by its flight path of 185 m. In our experiment, fission events were identified by detection of both fission fragments in time coincidence in the two PPAC detectors flanking the corresponding target. This technique allowed us to discriminate the fission events from the background produced by α disintegration of radioactive samples and by particles produced in spallation reactions. Because PPAC detectors are insensitive to the γ flash, it is possible to reach energies as high as 1 GeV. The stripped cathodes provide the spatial position of the hits in the detectors, so that the emission angle of the fission fragments can be measured. Inside the reaction cham...

  17. Neutron capture cross section measurement of 238U at the n TOF CERN facility with C6D6 scintillation detectors in the energy region from 1 eV to 700 keV

    CERN Document Server

    Mingrone, F.

    2017-01-01

    The aim of this work is to provide a precise and accurate measurement of the 238U(n,g) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behaviour of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross-section of 238U should be further reduced to 1-3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were proposed and carrie...

  18. Evaluación de la espectrometría de masas: MALDI-TOF MS para la identificación rápida y confiable de levaduras

    Directory of Open Access Journals (Sweden)

    María S Relloso

    2015-06-01

    Full Text Available La espectrometría de masas, conocida como matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS, es una técnica utilizada en la identificación de microorganismos mediante la creación de un espectro basado en el perfil de proteínas, que es único para una especie dada. El objetivo del presente trabajo fue evaluar la identificación de aislamientos clínicos de levaduras por MALDI-TOF MS en un hospital universitario de Argentina y analizar 2 procedimientos para la extracción de proteínas: el recomendado por el fabricante del equipo y una técnica abreviada rápida. Utilizando el primero de estos procedimientos se analizaron 201 aislamientos identificados previamente por métodos convencionales y se obtuvo coincidencia en la identificación a nivel de especie en el 95,38 % de los aislamientos analizados. Con 100 de estos aislamientos se utilizó, además, el procedimiento abreviado para la extracción de proteínas; se obtuvo una identificación correcta a nivel de género y especie en el 98,0 % de ellos. La espectrometría de masas MALDI-TOF MS demostró ser una técnica rápida, sencilla y precisa para la identificación de levaduras.

  19. GEANT4 simulation of the neutron background of the C{sub 6}D{sub 6} set-up for capture studies at n{sub T}OF

    Energy Technology Data Exchange (ETDEWEB)

    Žugec, P., E-mail: pzugec@phy.hr [Department of Physics, Faculty of Science, University of Zagreb (Croatia); Colonna, N. [Istituto Nazionale di Fisica Nucleare, Bari (Italy); Bosnar, D. [Department of Physics, Faculty of Science, University of Zagreb (Croatia); Altstadt, S. [Johann-Wolfgang-Goethe Universität, Frankfurt (Germany); Andrzejewski, J. [Uniwersytet Łódzki, Lodz (Poland); Audouin, L. [Centre National de la Recherche Scientifique/IN2P3 – IPN, Orsay (France); Barbagallo, M. [Istituto Nazionale di Fisica Nucleare, Bari (Italy); Bécares, V. [Centro de Investigaciones Energeticas Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain); Bečvář, F. [Charles University, Prague (Czech Republic); Belloni, F. [Commissariat à l' Énergie Atomique (CEA) Saclay – Irfu, Gif-sur-Yvette (France); Berthoumieux, E. [Commissariat à l' Énergie Atomique (CEA) Saclay – Irfu, Gif-sur-Yvette (France); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Billowes, J. [University of Manchester, Oxford Road, Manchester (United Kingdom); Boccone, V.; Brugger, M.; Calviani, M. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Calviño, F. [Universitat Politecnica de Catalunya, Barcelona (Spain); Cano-Ott, D. [Centro de Investigaciones Energeticas Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain); Carrapiço, C. [Instituto Tecnológico e Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, Lisboa (Portugal); Cerutti, F. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); and others

    2014-10-01

    The neutron sensitivity of the C{sub 6}D{sub 6} detector setup used at n{sub T}OF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n{sub T}OF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a {sup nat}C sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured {sup nat}C yield has been discovered, which prevents the use of {sup nat}C data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron background for two different samples are demonstrating the important role of accurate simulations of the neutron background in capture cross-section measurements.

  20. Micromegas detector for $^{33}$S(n,$\\alpha$) cross section measurement at n_TOF

    CERN Multimedia

    The present proposal is a consequence of the successful tests performed in 2011 related to the Letter of Intent CERN-INTC-2010-023/I-092. The main goal of this proposal is a first (n,$\\alpha$) cross section measurement with the Micromegas detector presently running at n_TOF for monitoring purposes and fission cross section measurements. The $^{33}$S(n,$\\alpha$) cross section is of interest in astrophysics mainly due to the origin of $^{36}$S which is still an open question. $^{33}$S is also of interest in medical physics since it has been proposed as a possible/alternative cooperating target to boron neutron capture therapy. Important discrepancies between previous measurements of $^{33}$S(n,$\\alpha$) cross section and especially between the resonance parameters are found in the literature. We propose to measure the (n,$\\alpha$) cross section of the stable isotope $^{33}$S in the energy range up to 300 keV covering the astrophysical range of interest. The possibility of increasing this energy range will be st...

  1. (237)Np(n,f) Cross Section: New Data and Present Status

    CERN Document Server

    Paradela, C; Carrapico, C; Eleftheriadis, C; Leeb, H; Calvino, F; Herrera-Martinez, A; Savvidis, I; Vlachoudis, V; Haas, B; Vannini, G; Le Naour, C; Gramegna, F; Wiescher, M; Pigni, M T; Audouin, L; Mengoni, A; Quesada, J; Becvar, F; Plag, R; Cennini, P; Mosconi, M; Duran, I; Rauscher, T; Couture, A; Capote, R; Sarchiapone, L; Vlastou, R; Domingo-Pardo, C; Dillmann, I; Pavlopoulos, P; Karamanis, D; Krticka, M; Jericha, E; Ferrari, A; Martinez, T; Trubert, D; Oberhummer, H; Karadimos, D; Plompen, A; Isaev, S; Terlizzi, R; Kaeppeler, F; Cortes, G; Cox, J; Voss, F; Pretel, C; Colonna, N; Berthoumieux, E; Vaz, P; Heil, M; Lopes, I; Lampoudis, C; Walter, S; Calviani, M; Gonzalez-Romero, E; Embid-Segura, M; Stephan, C; Igashira, M; Papachristodoulou, C; Aerts, G; Tavora, L; Berthier, B; Rudolf, G; Andrzejewski, J; Villamarin, D; Ferreira-Marques, R; Tain, J L; O'Brien, S; Gunsing, F; Reifarth, R; Perrot, L; Lindote, A; Neves, F; Poch, A; Kerveno, M; Rubbia, C; Koehler, P; Dahlfors, M; Wisshak, K; Salgado, J; Dridi, W; Ventura, A; Andriamonje, S; Assimakopoulos, P; Santos, C; Ferrant, L; Lozano, M; Patronis, N; Chiaveri, E; Guerrero, C; Kadi, Y; Vicente, M C; Praena, J; Baumann, P; Oshima, M; Rullhusen, P; Furman, W; David, S; Marrone, S; Tassan-Got, L; Cano-Ott, D; Pavlix, A; Alvarez-Velarde, F; Massimi, C; Mastinu, P; Pancin, J; Papadopoulos, C; Tagliente, G; Haight, R; Chepel, V; Kossionides, E; Badurek, G; Marganiec, J; Lukic, S; Tarrio, D; Alvarez, H

    2011-01-01

    In this document, we present the final result obtained at the n_TOF experiment; for the neutron-induced fission cross section of the (237)Np, from the fission threshold up to 1 GeV. The method applied to get tins result is briefly discussed. n_TOF data are compared to the last experimental measurements using other TOF facilities or the surrogate method, reported experiments performed with monoenergetic sources and the FISCAL systematic, including a discussion about the existing discrepancies.

  2. Measurement of the Neutron Capture Cross Sections of $^{233}$U, $^{237}$Np, $^{240,242}$Pu, $^{241,243}$Am and $^{245}$Cm with a Total Absorption Calorimeter at n_TOF

    CERN Multimedia

    Beer, H; Wiescher, M; Cox, J; Rapp, W; Embid, M; Dababneh, S

    2002-01-01

    Accurate and reliable neutron capture cross section data for actinides are necessary for the poper design, safety regulation and precise performance assessment of transmutation devices such as Fast Critical Reactors or Accelerator Driven Systems (ADS). The goal of this proposal is the measurement of the neutron capture cross sections of $^{233}$U, $^{237}$Np, $^{240,242}$Pu, $^{241,243}$Am and $^{245}$Cm at n_TOF with an accuracy of 5~\\%. $^{233}$U plays an essential role in the Th fuel cycle, which has been proposed as a safer and cleaner alternative to the U fuel cycle. The capture cross sections of $^{237}$Np,$^{240,242}$Pu, $^{241,243}$Am and $^{245}$Cm play a key role in the design and optimization of a strategy for the Nuclear Waste Transmutation. A high accuracy can be achieved at n_TOF in such measurements due to a combination of features unique in the world: high instantaneous neutron fluence and excellent energy resolution of the facility, innovative Data Acquisition System based on flash ADCs and t...

  3. La mesure du danger

    CERN Document Server

    Manceron, Vanessa; Revet, Sandrine

    2014-01-01

    La mesure du danger permet d’explorer des dangers de nature aussi diverse que la délinquance, la pollution, l’écueil maritime, la maladie ou l’attaque sorcellaire, l’extinction d’espèces animales ou végétales, voire de la Planète tout entière. Au croisement de la sociologie, de l’anthropologie et de l’histoire, les différents articles analysent les pratiques concrètes de mesure pour tenter de comprendre ce qui se produit au cours de l’opération d’évaluation du danger sans préjuger de la nature de celui-ci. L’anthropologie a contribué à la réflexion sur l’infortune en s’intéressant aux temporalités de l’après : maladies, catastrophes, pandémies, etc. et en cherchant à rendre compte de l’expérience des victimes, de leur vie ordinaire bouleversée, de la recomposition du quotidien. Elle s’intéresse aussi aux autres types de mesures, les savoirs incorporés, qui reposent sur l’odorat, la vue ou le toucher et ceux qui ressortent d’une épistémologie « non ...

  4. Advanced nuclear energy systems and the need of accurate nuclear data: the n_TOF project at CERN

    CERN Document Server

    Colonna, N; Praena, J; Lederer, C; Karadimos, D; Sarmento, R; Domingo-Pardo, C; Plag, R; Massimi, C; Calviani, M; Guerrero, C; Paradela, C; Belloni, F

    2010-01-01

    To satisfy the world's constantly increasing demand for energy, a suitable mix of different energy sources has to be devised. In this scenario, an important role could be played by nuclear energy, provided that major safety, waste and proliferation issues affecting current nuclear reactors are satisfactorily addressed. To this purpose, a large effort has been under way for a few years towards the development of advanced nuclear systems with the aim of closing the fuel cycle. Generation IV reactors, with full or partial waste recycling capability, accelerator driven systems, as well as new fuel cycles are the main options being investigated. The design of advanced systems requires improvements in basic nuclear data, such as cross-sections for neutron-induced reactions on actinides. In this paper, the main concepts of advanced reactor systems are described, together with the related needs of new and accurate nuclear data. The present activity in this field at the neutron facility n\\_TOF at CERN is discussed.

  5. Sensitivity of chemical vapor deposition diamonds to DD and DT neutrons at OMEGA and the National Ignition Facility

    Science.gov (United States)

    Kabadi, N. V.; Sio, H.; Glebov, V.; Gatu Johnson, M.; MacPhee, A.; Frenje, J. A.; Li, C. K.; Seguin, F.; Petrasso, R.; Forrest, C.; Knauer, J.; Rinderknecht, H. G.

    2016-11-01

    The particle-time-of-flight (pTOF) detector at the National Ignition Facility (NIF) is used routinely to measure nuclear bang-times in inertial confinement fusion implosions. The active detector medium in pTOF is a chemical vapor deposition diamond. Calibration of the detectors sensitivity to neutrons and protons would allow measurement of nuclear bang times and hot spot areal density (ρR) on a single diagnostic. This study utilizes data collected at both NIF and Omega in an attempt to determine pTOF's absolute sensitivity to neutrons. At Omega pTOF's sensitivity to DT-n is found to be stable to within 8% at different bias voltages. At the NIF pTOF's sensitivity to DD-n varies by up to 59%. This variability must be decreased substantially for pTOF to function as a neutron yield detector at the NIF. Some possible causes of this variability are ruled out.

  6. Mesures de procédure spéciales et respect des droits de l'homme Rapport général

    NARCIS (Netherlands)

    Vervaele, J.A.E.

    2009-01-01

    Le but du rapport général est de mener une analyse comparative des rapports nationaux en vue de présenter les processus de transformation des systèmes de justice pénale internes, en particulier du procès pénal, étant donné que des mesures procédurales spéciales sont introduites pour appréhender le

  7. Monte carlo simulations of the n_TOF lead spallation target with the Geant4 toolkit: A benchmark study

    Directory of Open Access Journals (Sweden)

    Lerendegui-Marco J.

    2017-01-01

    Full Text Available Monte Carlo (MC simulations are an essential tool to determine fundamental features of a neutron beam, such as the neutron flux or the γ-ray background, that sometimes can not be measured or at least not in every position or energy range. Until recently, the most widely used MC codes in this field had been MCNPX and FLUKA. However, the Geant4 toolkit has also become a competitive code for the transport of neutrons after the development of the native Geant4 format for neutron data libraries, G4NDL. In this context, we present the Geant4 simulations of the neutron spallation target of the n_TOF facility at CERN, done with version 10.1.1 of the toolkit. The first goal was the validation of the intra-nuclear cascade models implemented in the code using, as benchmark, the characteristics of the neutron beam measured at the first experimental area (EAR1, especially the neutron flux and energy distribution, and the time distribution of neutrons of equal kinetic energy, the so-called Resolution Function. The second goal was the development of a Monte Carlo tool aimed to provide useful calculations for both the analysis and planning of the upcoming measurements at the new experimental area (EAR2 of the facility.

  8. Monte carlo simulations of the n_TOF lead spallation target with the Geant4 toolkit: A benchmark study

    Science.gov (United States)

    Lerendegui-Marco, J.; Cortés-Giraldo, M. A.; Guerrero, C.; Quesada, J. M.; Meo, S. Lo; Massimi, C.; Barbagallo, M.; Colonna, N.; Mancussi, D.; Mingrone, F.; Sabaté-Gilarte, M.; Vannini, G.; Vlachoudis, V.; Aberle, O.; Andrzejewski, J.; Audouin, L.; Bacak, M.; Balibrea, J.; Bečvář, F.; Berthoumieux, E.; Billowes, J.; Bosnar, D.; Brown, A.; Caamaño, M.; Calviño, F.; Calviani, M.; Cano-Ott, D.; Cardella, R.; Casanovas, A.; Cerutti, F.; Chen, Y. H.; Chiaveri, E.; Cortés, G.; Cosentino, L.; Damone, L. A.; Diakaki, M.; Domingo-Pardo, C.; Dressler, R.; Dupont, E.; Durán, I.; Fernández-Domínguez, B.; Ferrari, A.; Ferreira, P.; Finocchiaro, P.; Göbel, K.; Gómez-Hornillos, M. B.; García, A. R.; Gawlik, A.; Gilardoni, S.; Glodariu, T.; Gonçalves, I. F.; González, E.; Griesmayer, E.; Gunsing, F.; Harada, H.; Heinitz, S.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Kalamara, A.; Kavrigin, P.; Kimura, A.; Kivel, N.; Kokkoris, M.; Krtička, M.; Kurtulgil, D.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Lonsdale, S. J.; Macina, D.; Marganiec, J.; Martínez, T.; Masi, A.; Mastinu, P.; Mastromarco, M.; Maugeri, E. A.; Mazzone, A.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Musumarra, A.; Negret, A.; Nolte, R.; Oprea, A.; Patronis, N.; Pavlik, A.; Perkowski, J.; Porras, I.; Praena, J.; Radeck, D.; Rauscher, T.; Reifarth, R.; Rout, P. C.; Rubbia, C.; Ryan, J. A.; Saxena, A.; Schillebeeckx, P.; Schumann, D.; Smith, A. G.; Sosnin, N. V.; Stamatopoulos, A.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tassan-Got, L.; Valenta, S.; Variale, V.; Vaz, P.; Ventura, A.; Vlastou, R.; Wallner, A.; Warren, S.; Woods, P. J.; Wright, T.; Žugec, P.

    2017-09-01

    Monte Carlo (MC) simulations are an essential tool to determine fundamental features of a neutron beam, such as the neutron flux or the γ-ray background, that sometimes can not be measured or at least not in every position or energy range. Until recently, the most widely used MC codes in this field had been MCNPX and FLUKA. However, the Geant4 toolkit has also become a competitive code for the transport of neutrons after the development of the native Geant4 format for neutron data libraries, G4NDL. In this context, we present the Geant4 simulations of the neutron spallation target of the n_TOF facility at CERN, done with version 10.1.1 of the toolkit. The first goal was the validation of the intra-nuclear cascade models implemented in the code using, as benchmark, the characteristics of the neutron beam measured at the first experimental area (EAR1), especially the neutron flux and energy distribution, and the time distribution of neutrons of equal kinetic energy, the so-called Resolution Function. The second goal was the development of a Monte Carlo tool aimed to provide useful calculations for both the analysis and planning of the upcoming measurements at the new experimental area (EAR2) of the facility.

  9. Characterizing ICF Neutron Scintillation Diagnostics on the nTOF line at SUNY Geneseo

    Science.gov (United States)

    Lawson-Keister, Pat; Padawar-Curry, Jonah; Visca, Hannah; Fletcher, Kurt; Padalino, Stephen; Sangster, T. Craig; Regan, Sean

    2015-11-01

    Neutron scintillator diagnostics for ICF and HEDP can be characterized using the neutron time-of-flight (nTOF) line on Geneseo's 1.7 MV tandem Pelletron accelerator. Neutron signals can be differentiated from gamma signals by employing coincidence methods. A 1.8-MeV beam of deuterons incident on a deuterated polyethylene target produces neutrons via the 2H(d,n)3He reaction. Neutrons emerging at a lab angle of 88° have an energy of 2.96 MeV; the 3He ions associated with these neutrons are detected at a scattering angle of 43° using a surface barrier detector. The time of flight of the neutron can be measured by using the 3He detection as a ``start'' signal and the scintillation detection as a ``stop'' signal. This time of flight requirement is used to identify the 2.96-MeV neutron signals in the scintillator. To measure the light curve produced by these monoenergetic neutrons, two photomultiplier (PMT) tubes are attached to the scintillator. The full aperture PMT establishes the nTOF coincidence. The other PMT is fitted with a pinhole to collect single events. The time between the full aperture PMT signal and the arrival of the signal in the pinhole PMT is used to determine the light curve for the scintillator. This system will enable the neutron response of various scintillators to be compared. Supported in part by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  10. Mesures de teneurs en eau volumique et massique sur du sable

    OpenAIRE

    FAUCHARD, Cyrille; GUILBERT, Vincent; SAGNARD, Florence; FROUMENTIN, Michel

    2009-01-01

    Usuellement, la mesure par séchage en étuve et la mesure de la masse volumique humide par méthode nucléaire permettent de relier la teneur en eau massique à la teneur en eau volumique. La méthodologie étudiée ici propose d'associer à la mesure de la masse volumique humide une estimation de la teneur en eau volumique par des méthodes électromagnétiques via la mesure de la permittivité diélectrique apparente du sol. Ce paramètre physique peut être relié à la teneur en eau volumique par une loi ...

  11. Fission Fragment Angular Distributions in the $^{234}$U(n,f) and $^{236}$U(n,f) reactions

    CERN Multimedia

    We propose to measure the fission fragment angular distribution (FFAD) of the $^{234}$U(n,f) and $^{236}$U (n,f) reactions with the PPAC detection setup used in previous n_TOF-14 experiment. This experiment would take advantage of the high resolution of the n_TOF facility to investigate the FFAD behaviour in the pronounced vibrational resonances that have been observed between 0.1 and 2 MeV for the thorium cycle isotopes. In addition, the angular distribution of these isotopes will be measured for the first time beyond 14 MeV. Furthermore, the experiment will also provide the fission cross section with reduced statistical uncertainty, extending the $^{236}$U(n,f) data up to 1 GeV

  12. Measurement and analysis of the 241Am(n,γ) cross section at the CERN nTOF facility

    International Nuclear Information System (INIS)

    Fraval, Kevin

    2013-01-01

    In the context of the current nuclear technology, the radiotoxicity of the spent fuel of a typical PWR reactor is dominated by minor actinides for times greater than 10 4 years. In particular, 241 Am and its 432 years half-life is responsible for about half of the minor actinide content of a PWR spent fuel. This thesis work consisted in measuring and analysing the 241 Am(n,γ) cross section at the CERN n T OF facility. After selecting exclusively the events obtained with lead shielding in front of the C 6 D 6 detectors, the amplitude-energy calibration has to be adjusted with time, by using a photon coming from the 27 Al(α,p) 30 Si * reaction. Histogram extraction included applying a weighting function (obtained by MCNP simulation), a dead time correction, and a normalization to the compound nucleus excitation energy. The background corrected spectra were normalized relatively to the 4.9 eV resonance on 197 Au. Finally, the resonance analysis was performed using the SAMMY code. The extracted thermal value is 678±68 barns, the uncertainty being mostly due to the large background level. The resolved range was extended from 150 eV to 320 eV, with a total of 192 resonances that had to be added of heavily modified. The unresolved region was analysed up to 150 keV, yielding a larger average cross section than previously evaluated below 20 keV. (author) [fr

  13. Mesure de la vitesse d'infiltration des eaux dans le sol : Cas des sols ...

    African Journals Online (AJOL)

    SARAH

    30 avr. 2016 ... Pour ceux, il est nécessaire d'opter pour une agriculture moderne ... à une telle agriculture. Mots clés : mesure, vitesse, infiltration, sols, pollutions, eau, Niari, Congo .... une porosité tubulaire d'origine biologique. Toutes ces.

  14. Fine structure and spectral index measurements in natural uranium - graphite lattices; Mesures fines dans des reseaux a graphite

    Energy Technology Data Exchange (ETDEWEB)

    Cogne, F; Journet, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The experiments described in this report have been carried out for the most part in the critical facility MARIUS, and a few during the start up of the EDF-1 power reactor. The first part deals with the fine structure measurements made in various lattices and with their analysis. Integration over the neutron spectrum of the mono-kinetic disadvantage factor derived by the A.B.H method yields results in good agreement with the experiments. The second part deals with spectral indexes measurements (Pu/U, In/Mn) made at room temperature in MARIUS. Comparison are made of experiments with calculations using various thermalization models. Experiments carried out at higher temperatures in EDF-1 are also described. (authors) [French] Les mesures decrites dans ce rapport ont ete faites pour la plupart dans l'empilement critique MARIUS sur des reseaux a graphite-uranium naturel. Une premiere partie traite des mesures de structure fine faites dans differents reseaux et de leur interpretation. On montre en particulier qu'une integration sur le spectre d'un calcul monocinetique type A.B.H. rend bien compte des experiences. Dans une deuxieme partie, on donne les resultats de mesures d'indices de spectre Pu/U et In/Mn faites sur des reseaux froids a MARIUS et leur comparaison avec les differents modeles de calculs de thermalisation. On donne egalement les resultats de quelques mesures en temperature effectuees lors du demarrage du reacteur EDF-1. (auteurs)

  15. Developments for the TOF Straw Tracker

    Energy Technology Data Exchange (ETDEWEB)

    Ucar, A.

    2006-07-01

    COSY-TOF is a very large acceptance spectrometer for charged particles using precise information on track geometry and time of flight of reaction products. It is an external detector system at the Cooler Synchrotron and storage ring COSY in Juelich. In order to improve the performance of the COSY-TOF, a new tracking detector ''Straw Tracker'' is being constructed which combines very low mass, operation in vacuum, very good resolution, high sampling density and very high acceptance. A comparison of pp{yields}d{pi}{sup +} data and a simulation using the straw tracker with geometry alone indicates big improvements with the new tracker. In order to investigate the straw tracker properties a small tracking hodoscope ''cosmic ray test facility'' was constructed in advance. It is made of two crossed hodoscopes consisting of 128 straw tubes arranged in 4 double planes. For the first time Juelich straws have been used for 3 dimensional reconstruction of cosmic ray tracks. In this illuminating field the space dependent response of scintillators and a straw tube were studied. (orig.)

  16. Developments for the TOF Straw Tracker

    International Nuclear Information System (INIS)

    Ucar, A.

    2006-01-01

    COSY-TOF is a very large acceptance spectrometer for charged particles using precise information on track geometry and time of flight of reaction products. It is an external detector system at the Cooler Synchrotron and storage ring COSY in Juelich. In order to improve the performance of the COSY-TOF, a new tracking detector ''Straw Tracker'' is being constructed which combines very low mass, operation in vacuum, very good resolution, high sampling density and very high acceptance. A comparison of pp→dπ + data and a simulation using the straw tracker with geometry alone indicates big improvements with the new tracker. In order to investigate the straw tracker properties a small tracking hodoscope ''cosmic ray test facility'' was constructed in advance. It is made of two crossed hodoscopes consisting of 128 straw tubes arranged in 4 double planes. For the first time Juelich straws have been used for 3 dimensional reconstruction of cosmic ray tracks. In this illuminating field the space dependent response of scintillators and a straw tube were studied. (orig.)

  17. Automatic measuring device for atomic oxygen concentrations (1962); Dispositif de mesure automatique de concentrations d'oxygene atomique (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J; Deiss, M; Mercier, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    Within the framework of the activities of the Autonomous Reactor Electronics Section we have developed a device, which renders automatic one type of measurement carried out in the Physical Chemistry Department at the Saclay Research Centre. We define here: - the physico-chemical principle of the apparatus which is adapted to the measurement of atomic oxygen concentrations; - the physical principle of the automatic measurement; - the properties, performance, constitution, use and maintenance of the automatic measurement device. It is concluded that the principle of the automatic device, whose tests have confirmed the estimation of the theoretical performance, could usefully be adapted to other types of measurement. (authors) [French] Dans le cadre des activites de la Section Autonome d'Electronique des Reacteurs, il a ete realise et mis au point un dispositif permettant de rendre automatique un type de mesures effectuees au Departement de Physico-Chimie du C.E.N. SACLAY. On definit ici: - le principe physico-chimique de l'appareillage, adapte a la mesure de concentrations de l'oxygene atomique; - le principe physique de la mesure automatique; - les qualites, performances, constitution, utilisation, et maintenance du dispositif de mesure automatique. Il est porte en conclusion, que le principe du dispositif automatique realise, dont les essais ont sensiblement confirme l'evaluation des performances theoriques, pourrait etre utilement adapte a d'autres types de mesures courantes. (auteurs)

  18. Experimental setup and procedure for the measurement of the 7Be(n,p)7Li reaction at n_TOF

    Science.gov (United States)

    Barbagallo, M.; Andrzejewski, J.; Mastromarco, M.; Perkowski, J.; Damone, L. A.; Gawlik, A.; Cosentino, L.; Finocchiaro, P.; Maugeri, E. A.; Mazzone, A.; Dressler, R.; Heinitz, S.; Kivel, N.; Schumann, D.; Colonna, N.; Aberle, O.; Amaducci, S.; Audouin, L.; Bacak, M.; Balibrea, J.; Bečvář, F.; Bellia, G.; Berthoumieux, E.; Billowes, J.; Bosnar, D.; Brown, A.; Caamaño, M.; Calviño, F.; Calviani, M.; Cano-Ott, D.; Cardella, R.; Casanovas, A.; Cerutti, F.; Chen, Y. H.; Chiaveri, E.; Cortés, G.; Cortés-Giraldo, M. A.; Cristallo, S.; Diakaki, M.; Dietz, M.; Domingo-Pardo, C.; Dupont, E.; Durán, I.; Fernández-Domínguez, B.; Ferrari, A.; Ferreira, P.; Furman, V.; Göbel, K.; García, A. R.; Gilardoni, S.; Glodariu, T.; Gonçalves, I. F.; González-Romero, E.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Harada, H.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Johnston, K.; Käppeler, F.; Kadi, Y.; Kalamara, A.; Kavrigin, P.; Kimura, A.; Kokkoris, M.; Krtička, M.; Kurtulgil, D.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Lerendegui-Marco, J.; Lo Meo, S.; Lonsdale, S. J.; Macina, D.; Manna, A.; Marganiec, J.; Martínez, T.; Martins-Correia, J. G.; Masi, A.; Massimi, C.; Mastinu, P.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Musumarra, A.; Negret, A.; Nolte, R.; Oprea, A.; Pappalardo, A. D.; Patronis, N.; Pavlik, A.; Piscopo, M.; Porras, I.; Praena, J.; Quesada, J. M.; Radeck, D.; Rauscher, T.; Reifarth, R.; Robles, M. S.; Rubbia, C.; Ryan, J. A.; Sabaté-Gilarte, M.; Saxena, A.; Schell, J.; Schillebeeckx, P.; Sedyshev, P.; Smith, A. G.; Sosnin, N. V.; Stamatopoulos, A.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tassan-Got, L.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Warren, S.; Weiss, C.; Woods, P. J.; Wright, T.; Žugec, P.

    2018-04-01

    Following the completion of the second neutron beam line and the related experimental area (EAR2) at the n_TOF spallation neutron source at CERN, several experiments were planned and performed. The high instantaneous neutron flux available in EAR2 allows to investigate neutron induced reactions with charged particles in the exit channel even employing targets made out of small amounts of short-lived radioactive isotopes. After the successful measurement of the 7Be(n, α) α cross section, the 7Be(n,p)7Li reaction was studied in order to provide still missing cross section data of relevance for Big Bang Nucleosynthesis (BBN), in an attempt to find a solution to the cosmological Lithium abundance problem. This paper describes the experimental setup employed in such a measurement and its characterization.

  19. Measurement of the resonance escape probability; Mesure de l'absorption resonnante

    Energy Technology Data Exchange (ETDEWEB)

    Anthony, J P; Bacher, P; Lheureux, L; Moreau, J; Schmitt, A P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The average cadmium ratio in natural uranium rods has been measured, using equal diameter natural uranium disks. These values correlated with independent measurements of the lattice buckling, enabled us to calculate values of the resonance escape probability for the G1 reactor with one or the other of two definitions. Measurements were performed on 26 mm and 32 mm rods, giving the following values for the resonance escape probability p: 0.8976 {+-} 0.005 and 0.912 {+-} 0.006 (d. 26 mm), 0.8627 {+-} 0.009 and 0.884 {+-} 0.01 (d. 32 mm). The influence of either definition on the lattice parameters is discussed, leading to values of the effective integral. Similar experiments have been performed with thorium rods. (author) [French] Nous avons mesure le rapport cadmium moyen dans des barres d'uranium a l'aide de disques d'uranium naturel de meme diametre que ces dernieres. Ces mesures nous ont permis, conjointement avec des mesures de Laplacien du reseau, de determiner deux facteurs antitrappes du reacteur G1 correspondant a deux definitions exposees. Les mesures ont ete faites sur deux diametres de barres 26 et 32 mm. Resultats: 0.8976 {+-} 0.005 and 0.912 {+-} 0.006 (d. 26 mm), 0.8627 {+-} 0.009 and 0.884 {+-} 0.01 (d. 32 mm). L'influence de ces deux definitions sur les divers parametres du reseau, est discutee. La determination de 'p' pour un diametre de barres d'uranium de 26 mm, et les mesures de variation de Laplacien, nous ont permis de calculer une valeur de l'integrale effective correspondant a chaque definition. Les mesures analogues faites sur des barres de thorium sont egalement indiquees. (auteur)

  20. Neutron capture cross section measurement of $^{151}Sm$ at the CERN neutron Time of Flight Facility (nTOF)

    CERN Document Server

    Abbondanno, U; Alvarez-Velarde, F; Alvarez-Pol, H; Andriamonje, Samuel A; Andrzejewski, J; Badurek, G; Baumann, P; Becvar, F; Benlliure, J; Berthoumieux, E; Calviño, F; Cano-Ott, D; Capote, R; Cennini, P; Chepel, V; Chiaveri, Enrico; Colonna, N; Cortés, G; Cortina-Gil, D; Couture, A; Cox, J; Dababneh, S; Dahlfors, M; David, S; Dolfini, R; Domingo-Pardo, C; Durán, I; Embid-Segura, M; Ferrant, L; Ferrari, A; Ferreira-Marques, R; Frais-Kölbl, H; Furman, W; Gonçalves, I; Gallino, R; Gonzalez-Romero, E; Goverdovski, A; Gramegna, F; Griesmayer, E; Gunsing, F; Haas, B; Haight, R; Heil, M; Herrera-Martínez, A; Isaev, S; Jericha, E; Kappeler, F; Kadi, Y; Karadimos, D; Kerveno, M; Ketlerov, V; Köhler, P; Konovalov, V; Krticka, M; Lamboudis, C; Leeb, H; Lindote, A; Lopes, I; Lozano, M; Lukic, S; Marganiec, J; Marrone, S; Martinez-Val, J; Mastinu, P; Mengoni, A; Milazzo, P M; Molina-Coballes, A; Moreau, C; Mosconi, M; Neves, F; Oberhummer, Heinz; O'Brien, S; Pancin, J; Papaevangelou, T; Paradela, C; Pavlik, A; Pavlopoulos, P; Perlado, J M; Perrot, L; Pignatari, M; Plag, R; Plompen, A; Plukis, A; Poch, A; Policarpo, Armando; Pretel, C; Quesada, J; Raman, S; Rapp, W; Rauscher, T; Reifarth, R; Rosetti, M; Rubbia, Carlo; Rudolf, G; Rullhusen, P; Salgado, J; Soares, J C; Stéphan, C; Tagliente, G; Taín, J L; Tassan-Got, L; Tavora, L; Terlizzi, R; Vannini, G; Vaz, P; Ventura, A; Villamarín, D; Vincente, M C; Vlachoudis, V; Voss, F; Wendler, H; Wiescher, M; Wissha, K

    2004-01-01

    The measurement of **1**5**1Sm(n, gamma)**1**5**2Sm (samarium) cross section showed improved performance of the new spallation neutron facility. It covered a wide energy range with good resolution, high neutron flux, low backgrounds and a favourable duty factor. The samarium cross section was found to be of great importance for characterizing neutron capture nucleosynthesis in asymptotic giant stars. The combination of these features provided a promising basis for a broad experimental program directed towards application in astrophysics and advanced nuclear technologies. (Edited abstract)

  1. Measurement of a thermal neutron flux using air activation; Mesure de flux de neutrons thermiques par activation d'air

    Energy Technology Data Exchange (ETDEWEB)

    Guyonvarh, M; Lecomte, P; Le Meur, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    It is necessary to know, in irradiation loops, the thermal neutron flux after the irradiation device has been introduced and without being obliged to wait for the discharge of this device. In order to measure the flux and to control it continuously, one possible method is to place in the flux a coiled steel tube through which air passes. By measuring the activity of argon 41, and with a knowledge of the flow rate and the temperature of the air, it is possible to calculate the flux. An air-circulation flux controller is described and the relationship between the flux and the count rate is established The accuracy of an absolute measurement is about 14 per cent; that of a relative measurement is about 3 per cent. The measurement can be carried out equally well whether the reactor is operating at maximum or at low power. The measurement range goes from 10{sup 9} to lO{sup 15} n.cm{sup -2}.sec{sup -1}, and it would be possible after a few modifications to measure fluxes between 10{sup 5} and 10{sup 15} n.cm{sup -2}.sec{sup -1}. Finally, the method is very safe to operate: there is little risk of irradiation because of the low specific activity of the argon-41 formed, and no risk of contamination because the decay product of argon-41 is stable. This method, which is now being used in loops, is thus very practical. (authors) [French] Sur des boucles d'irradiation il est necessaire de connaitre le flux de neutrons thermiques apres mise en place du dispositif d'irradiation et sans etre oblige d'attendre le detournement de ce dispositif. Pour mesurer le flux et le controler en permanence, une methode consiste a placer sous flux un serpentin en acier dans lequel on fait circuler de l'air. La mesure d'activite d'argon 41 permet de calculer le flux, connaissant le debit et la temperature de l'air. Un controleur de flux par circulation d'air est decrit et la relation entre le flux et le taux de comptage est etablie. La precision d'une mesure absolue est de l'ordre de 14 pour

  2. Clinical evaluation of TOF versus non-TOF on PET artifacts in simultaneous PET/MR: a dual centre experience

    Energy Technology Data Exchange (ETDEWEB)

    Voert, Edwin E.G.W. ter [University Hospital Zurich, Department of Nuclear Medicine, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Veit-Haibach, Patrick [University Hospital Zurich, Department of Nuclear Medicine, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); University Hospital Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); Ahn, Sangtae [GE Global Research, Niskayuna, NY (United States); Wiesinger, Florian [GE Global Research, Muenchen (Germany); Khalighi, M.M.; Delso, Gaspar [GE Healthcare, Waukesha, WI (United States); Levin, Craig S. [Stanford University, Department of Radiology, Molecular Imaging Program at Stanford, Stanford, CA (United States); Iagaru, Andrei H. [Stanford University, Department of Radiology, Division of Nuclear Medicine and Molecular Imaging, Stanford, CA (United States); Zaharchuk, Greg [Stanford University, Department of Radiology, Neuroradiology, Stanford, CA (United States); Huellner, Martin [University Hospital Zurich, Department of Nuclear Medicine, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); University Hospital Zurich, Department of Neuroradiology, Zurich (Switzerland)

    2017-07-15

    Our objective was to determine clinically the value of time-of-flight (TOF) information in reducing PET artifacts and improving PET image quality and accuracy in simultaneous TOF PET/MR scanning. A total 65 patients who underwent a comparative scan in a simultaneous TOF PET/MR scanner were included. TOF and non-TOF PET images were reconstructed, clinically examined, compared and scored. PET imaging artifacts were categorized as large or small implant-related artifacts, as dental implant-related artifacts, and as implant-unrelated artifacts. Differences in image quality, especially those related to (implant) artifacts, were assessed using a scale ranging from 0 (no artifact) to 4 (severe artifact). A total of 87 image artifacts were found and evaluated. Four patients had large and eight patients small implant-related artifacts, 27 patients had dental implants/fillings, and 48 patients had implant-unrelated artifacts. The average score was 1.14 ± 0.82 for non-TOF PET images and 0.53 ± 0.66 for TOF images (p < 0.01) indicating that artifacts were less noticeable when TOF information was included. Our study indicates that PET image artifacts are significantly mitigated with integration of TOF information in simultaneous PET/MR. The impact is predominantly seen in patients with significant artifacts due to metal implants. (orig.)

  3. MALDI-TOF MS/MS measurements of PMMA

    NARCIS (Netherlands)

    Becer, C.R.; Baumgaertel, A.; Gottschaldt, M.; Schubert, U.S.

    2008-01-01

    The polymer poly(Me methacrylate) (PMMA) was analyzed using the matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) technique. The MALDI-TOF MS app. was coupled with a collision-induced dissocn. (CID) unit. The performance of the MALDI-TOF/TOF MS method in

  4. Determination of the glycation sites of Bacillus anthracis neoglycoconjugate vaccine by MALDI-TOF/TOF-CID-MS/MS and LC-ESI-QqTOF-tandem mass spectrometry

    Science.gov (United States)

    Jahouh, Farid; Hou, Shu-jie; Kováč, Pavol; Banoub, Joseph H.

    2012-01-01

    We present herein an efficient mass spectrometric method for the localization of the glycation sites of a model neoglycoconjugate vaccine formed by a construct of the tetrasaccharide side chain of the Bacillus anthracis exosporium and the protein carrier bovine serum albumin. The glycoconjugate was digested with both trypsin and GluC V8 endoproteinases, and the digests were then analyzed by MALDI-TOF/TOF-CID-MS/MS and nano-LC-ESI-QqTOF-CID-MS/MS. The sequences of the unknown peptides analyzed by MALDI-TOF/TOF-CID-MS/MS, following digestion with the GluC V8 endoproteinase, allowed us to recognize three glycopeptides whose glycation occupancies were, respectively, on Lys 235, Lys 420, and Lys 498. Similarly, the same analysis was performed on the tryptic digests, which permitted us to recognize two glycation sites on Lys 100 and Lys 374. In addition, we have also used LC-ESI-QqTOF-CID-MS/MS analysis for the identification of the tryptic digests. However, this analysis identified a higher number of glycopeptides than would be expected from a glycoconjugate composed of a carbohydrate–protein ratio of 5.4:1, which would have resulted in glycation occupancies of 18 specific sites. This discrepancy was due to the large number of glycoforms formed during the synthetic carbohydrate–spacer–carrier protein conjugation. Likewise, the LC-ESI-QqTOF-MS/MS analysis of the GluC V8 digest also identified 17 different glycation sites on the synthetic glycoconjugate. PMID:22012665

  5. Assessment\tof\tnutritional\tstatus\tof\tchildren\tattending\tpaediatric\toutpatient department\tat\ta\ttertiary\tcare\thospital

    Directory of Open Access Journals (Sweden)

    Shreyash\tJ\tGandhi

    2015-10-01

    Full Text Available Background The nutrition status is always neglected issue of public health. The high prevalence of\tmalnutrition\tin\tNFHS data gives alarm to\twork for the children who\tare\tassets\tof\tour\tcountry\tin\tfuture. Objectives To study the nutritional status of children attending pediatric OPD by anthropometric\tmeasurements\tand\tto\tknow\tthe\thealth\tstatus\tof\tthese\tchildren and\ttheir\trelation\twith\tnutritional\tstatus. Methods The\tnutritional\tprofile\tof\tchildren\tof age\tgroup 0-5 years attending\tPaediatric OPD\tat\tNew\tCivil\tHospital\t(NCH,\tSurat\twas\tstudied.\tStratification\tto\tget\tequal representation of both gender by enrolling 50 boys and 50 girls of each age group 0-6\tmonths, 6-12\tmonths,\t1-2 years,\t2-3 years,\t3-4 years and 4-5 years was\tdone.\tTotal\t600\tchildren\tof\tage\tgroup\tof 0-5\tyears\twere\tenrolled. Results As per WHO growth standards, 17.5%, 46% and 39.33% children had wasting, stunting and underweight respectively. Total\tmalnutrition cases were 386 with a prevalence of 64.3\t%. Age group wise prevalence of under\tnutrition\twas\thighest\tin\t37-48\tmonths age group (69.2\t%.\tAs per assessment of nutritional status of children\taged\t6-60\tmonths\tusing MUAC,\t45.8\t%\tchildren\thave\tmild\tto\tmoderate\tmalnutrition\twhereas\t1.8\t% has\tsevere\tmalnutrition. Conclusion Malnutrition\tis\tmore\tin\tboys\tcompared\tto\tgirls.\tMalnutrition\twas\tmore\tprevalent\tin\t12-60\tmonths\tage\tgroup children\tand\twas\tfound\tstatistically\tsignificant. Reduction\tof\tmalnutrition\tin\t0-5\tage\tgroup\tcan\tbe\tensured\tby availability\tof\tsupplementary\tfeed.

  6. Measuring device for strong gamma-ray sources; Dispositif de mesure des fortes sources emettrices {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Engelman, J; Vagner, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    We are given the description of a hollow argon-filled cylindrical ionisation chamber which is to be used to measure gamma-emitting sources. The instrument is currently used at the Measures Department in routine gauging of some radioelements. Sources are introduced into the central part of the chamber through a remote handling device. Measures are directly registered, it is not worth while removing the source from the container; a deviation of the source has little effect on the ionization current. The chamber was gauged to test such elements as: {sup 198}Au, {sup 60}Co, {sup 192}Ir, {sup 24}Na, {sup 137}Cs. Its measuring power approximately ranges from 100 micro-curies to 5 curies. (author) [French] On decrit une chambre d'ionisation cylindrique creuse, a remplissage d'argon, destinee a la mesure des sources emettrices {gamma}. Cet appareil est utilise couramment par la Section Mesures pour l'etalonnage de routine d'un certain nombre de radioelements. Les sources sont mises en place au centre de la chambre par un dispositif de manipulation a distance. La mesure est faite directement, sans qu'il soit necessaire d'extraire la source de son container; un decentrement de la source n'a en effet pas d'influence sensible sur le courant d'ionisation. Cette chambre d'ionisation a ete etalonnee pour divers radioelements: {sup 198}Au, {sup 60}Co, {sup 192}Ir, {sup 24}Na, {sup 137}Cs. La flamme d'activite mesurable s'etend de 100 microcuries a 5 curies, environ. (auteur)

  7. [EXPRESS IDENTIFICATION OF POSITIVE BLOOD CULTURES USING DIRECT MALDI-TOF MASS SPECTROMETRY].

    Science.gov (United States)

    Popov, D A; Ovseenko, S T; Vostrikova, T Yu

    2015-01-01

    To evaluate the effectiveness of direct identification of pathogens of bacteremia by direct matrix assisted laser desorption ionization time-flight mass spectrometry (mALDI-TOF) compared to routine method. A prospective study included 211 positive blood cultures obtained from 116 patients (106 adults and 10 children, aged from 2 weeks to 77 years old in the ICU after open heart surgery. Incubation was carried out under aerobic vials with a sorbent for antibiotics Analyzer BacT/ALERT 3D 120 (bioMerieux, France) in parallel with the primary sieving blood cultures on solid nutrient media with subsequent identification of pure cultures using MALDI-TOF mass spectrometry analyzer Vitek MS, bioMerieux, France routine method), after appropriate sample preparation we carried out a direct (without screening) MALDI-TOF mass spectrometric study of monocomponental blood cultures (n = 201). using a routine method in 211 positive blood cultures we identified 23 types of microorganisms (Staphylococcus (n = 87), Enterobacteria- ceae (n = 71), Enterococci (n = 20), non-fermentative Gram-negative bacteria (n = 18), others (n = 5). The average time of incubation of samples to obtain a signal of a blood culture growth was 16.2 ± 7.4 h (from 3.75 to 51 hours.) During the first 12 hours of incubation, growth was obtained in 32.4% of the samples, and on the first day in 92.2%. In the direct mass spectrometric analysis mnonocomponental blood cultures (n = 201) is well defined up to 153 species of the sample (76.1%), while the share of successful identification of Gram-negative bacteria was higher than that of Gram-positive (85.4 and 69, 1%, respectively p = 0.01). The high degree of consistency in the results of standard and direct method of identifying blood cultures using MALDI-TOF mass spectrometry (κ = 0.96, p direct mass spectrometric analysis, including sample preparation, was no longer than 1 hour: The method of direct MALDI-TOF mass spectrometry allows to significantly speed up

  8. The application of n-γ discrimination in 252Cf spontaneous neutron TOF spectra measurement

    International Nuclear Information System (INIS)

    Zhou Haojun; Zhang Yi; Li Jiansheng; Jin Yu; Wang Jie; Li Chunyuan

    2004-01-01

    The BC501 scintillator is used as a fast neutron detector. The effect that the pulse rise time method was used to discriminate γ from 252 Cf spontaneous neutron TOF spectra is studied in the experiment. A pulse rise time separation spectra of γ and 252 Cf spontaneous neuron upon 1 MeV is obtained, the n-γ separation function reaches to 4.6. When the result of pulse rise time separation coincides with the time-of-flight spectra in which the neutron energy is upon 0.5 MeV, 0.8 MeV and 1.0 MeV, comparing with the anticoincidence, γ was eliminated 99.90% at least. (authors)

  9. Surface Laser Scanning Measurements for the n_TOF spallation target

    CERN Document Server

    Vlachoudis, V; Cennini, P; Lebbos, E; Lettry, J

    2010-01-01

    The n_TOF spallation target is made of pure lead immersed into cooling water. The target was operating normally from 2001 until august 2004, when an increased transfer of radioactive products from the spallation target to the cooling circuit has been observed. The target was considered damaged by the safety commission (SC/RP), and an investigation campaign started to verify the actual status of the target. According to FLUKA and Ansys calculations the target was working in the elastoplastic regime of the lead material, therefore a deformation might be expected. The present paper describes a laser photographic method and the results of a possible such deformation. The target had a surface activity of the order of 20 mSv/h, therefore we were forced to perform the measurement from distance. The used method, is based on a linelaser and a high resolution digital camera for retrieving the 3D position of the surface of the lead target. Similar methods are used in the film industry and animation studios for scanning ...

  10. GEANT4 simulation of the neutron background of the C$_6$D$_6$ set-up for capture studies at n_TOF

    CERN Document Server

    Žugec, P.; Bosnar, D.; Altstadt, S.; Andrzejewski, J.; Audouin, L.; Barbagallo, M.; Bécares, V.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Billowes, J.; Boccone, V.; Brugger, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Cortés, G.; Cortés-Giraldo, M.A.; Diakaki, M.; Domingo-Pardo, C.; Dressler, R.; Duran, I.; Dzysiuk, N.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Ganesan, S.; García, A.R.; Giubrone, G.; Gómez-Hornillos, M.B.; Gonçalves, I.F.; González-Romero, E.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Gurusamy, P.; Heinitz, S.; Jenkins, D.G.; Jericha, E.; Kadi, Y.; Käppeler, F.; Karadimos, D.; Kivel, N.; Koehler, P.; Kokkoris, M.; Krtička, M.; Kroll, J.; Langer, C.; Lederer, C.; Leeb, H.; Leong, L.S.; Lo Meo, S.; Losito, R.; Manousos, A.; Marganiec, J.; Martìnez, T.; Massimi, C.; Mastinu, P.F.; Mastromarco, M.; Meaze, M.; Mendoza, E.; Mengoni, A.; Milazzo, P.M.; Mingrone, F.; Mirea, M.; Mondalaers, W.; Paradela, C.; Pavlik, A.; Perkowski, J.; Plompen, A.; Praena, J.; Quesada, J.M.; Rauscher, T.; Reifarth, R.; Riego, A.; Roman, F.; Rubbia, C.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Tagliente, G.; Tain, J.L.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Versaci, R.; Vermeulen, M.J.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiß, C.; Wright, T.

    2014-05-09

    The neutron sensitivity of the C$_6$D$_6$ detector setup used at n_TOF for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a $^\\mathrm{nat}$C sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured $^\\mathrm{nat}$C yield has been discovered, which prevents the use of $^\\mathrm{nat}$C data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron backg...

  11. Neutron capture cross sections of $^{70,72,73,74,76}$ Ge at n_TOF EAR-1

    CERN Multimedia

    We propose to measure the (n;$\\gamma$ ) cross sections of the isotopes $^{70;72;73;74;76}$Ge. Neutron induced reactions on Ge are of importance for the astrophysical slow neutron capture process, which is responsible for forming about half of the overall elemental abundances heavier than Fe. The neutron capture cross section on Ge affects the abundances produced in this process for a number of heavier isotopes up to a mass number of A = 90. Additionally, neutron capture on Ge is of interest for low background experiments involving Ge detectors. Experimental cross section data presently available for Ge (n;$\\gamma$ ) are scarce and cover only a fraction of the neutron energy range of interest. (n;$\\gamma$ ) cross sections will be measured in the full energy range from 25 meV to about 200 keV at n TOF EAR-1.

  12. Mesures de procédure spéciales et respect des droits de l'homme Rapport général

    OpenAIRE

    Vervaele, J.A.E.

    2009-01-01

    Le but du rapport général est de mener une analyse comparative des rapports nationaux en vue de présenter les processus de transformation des systèmes de justice pénale internes, en particulier du procès pénal, étant donné que des mesures procédurales spéciales sont introduites pour appréhender le terrorisme et la criminalité organisée, et de voir si cela a conduit les pays à se départir de leur propres règles fondamentales, procédures, principes et standards des droits de l’homme applicables...

  13. A CVD Diamond Detector for (n,a) Cross-Section Measurements

    CERN Document Server

    Weiss, Christina; Griesmayer, Erich; Guerrero, Carlos

    A novel detector based on the chemical vapor deposition (CVD) diamond technology has been developed in the framework of this PhD, for the experimental determination of (n,a) cross-sections at the neutron time-of-flight facility n_TOF at CERN. The 59Ni(n,a)56Fe cross-section, which is relevant for astrophysical questions as well as for risk-assessment studies in nuclear technology, has been measured in order to validate the applicability of the detector for such experiments. The thesis is divided in four parts. In the introductory part the motivation for measuring (n,a) cross-sections, the experimental challenges for such measurements and the reasons for choosing the CVD diamond technology for the detector are given. This is followed by the presentation of the n_TOF facility, an introduction to neutron-induced nuclear reactions and a brief summary of the interaction of particles with matter. The CVD diamond technology and the relevant matters related to electronics are given as well in this first part of the t...

  14. Measurement of the neutron capture cross section of U234 in n-TOF at CERN for Generation IV nuclear reactors

    International Nuclear Information System (INIS)

    Dridi, W.

    2006-11-01

    Accurate and reliable neutron capture cross sections are needed in many research areas, including stellar nucleosynthesis, advanced nuclear fuel cycles, waste transmutation, and other applied programs. In particular, the accurate knowledge of U 234 (n,γ) reaction cross section is required for the design and realization of nuclear power plants based on the thorium fuel cycle. We have measured the neutron capture cross section of U 234 , with a 4π BaF 2 Total Absorption Calorimeter, at the recently constructed neutron time-of-flight facility n-TOF at CERN in the energy range from 0.03 eV to 1 MeV. Monte-Carlo simulations with GEANT4 and MCNPX of the detector response have been performed. After the background subtraction and correction with dead time and pile-up, the capture yield from 0.03 eV up to 1.5 keV was derived. The analysis of the capture yield in terms of R-matrix resonance parameters is discussed. We have identified 123 resonances and measured the resonance parameters in the energy range from 0.03 eV to 1.5 keV. The mean radiative width γ > is found to be (38.2 ± 1.5) meV and the mean spacing parameter 0 > is (11.0 ± 0.2) eV, both values agree well with recommended values

  15. Characterizing ICF Neutron Diagnostics on the nTOF line at SUNY Geneseo

    Science.gov (United States)

    Simone, Angela; Padalino, Stephen; Turner, Ethan; Ginnane, Mary Kate; Dubois, Natalie; Fletcher, Kurtis; Giordano, Michael; Lawson-Keister, Patrick; Harrison, Hannah; Visca, Hannah; Sangster, Craig; Regan, Sean

    2014-10-01

    Charged particle beams from the Geneseo 1.7 MV tandem Pelletron accelerator produce nuclear reactions that emit neutrons in the range of 0.5 to 17.9 MeV via the d(d,n)3He and 11B(d,n)12C reactions. The neutron energy and flux can be adjusted by controlling the accelerator beam current and potential. This adjustable neutron source makes it possible to calibrate ICF and HEDP neutron scintillator diagnostics. However, gamma rays which are often present during an accelerator-based calibration are difficult to differentiate from neutron signals in scintillators. To identify neutrons from gamma rays and to determine their energy, a permanent neutron time-of-flight (nTOF) line is being constructed. By detecting the scintillator signal in coincidence with an associated charged particle (ACP) produced in the reaction, the identity of the neutron can be known and its energy determined by time of flight. Using a 100% efficient surface barrier detector to count the ACPs, the absolute efficiency of the scintillator as a function of neutron energy can be determined. This is done by determining the ratio of the ACP counts in the singles spectrum to coincidence counts for matched solid angles of the SBD and scintillator. Funded in part by a LLE contract through the DOE.

  16. Neutron cross section measurements at n-TOF for ADS related studies

    International Nuclear Information System (INIS)

    Mastinu, P F; Abbondanno, U; Aerts, G

    2006-01-01

    A neutron Time-of-Flight facility (n T OF) is available at CERN since 2001. The innovative features of the neutron beam, in particular the high instantaneous flux, the wide energy range, the high resolution and the low background, make this facility unique for measurements of neutron induced reactions relevant to the field of Emerging Nuclear Technologies, as well as to Nuclear Astrophysics and Fundamental Nuclear Physics. The scientific motivations that have led to the construction of this new facility are here presented. The main characteristics of the n T OF neutron beam are described, together with the features of the experimental apparata used for cross-section measurements. The main results of the first measurement campaigns are presented. Preliminary results of capture cross-section measurements of minor actinides, important to ADS project for nuclear waste transmutation, are finally discussed

  17. [Utility of MALDI-TOF MS for the identification of anaerobic bacteria].

    Science.gov (United States)

    Zárate, Mariela S; Romano, Vanesa; Nievas, Jimena; Smayevsky, Jorgelina

    2014-01-01

    The analysis by MALDI-TOF MS (Matrix-assited laser desorption/ionization time-of-flight mass spectrometry) has become a reference method for the identification of microorganisms in Clinical Microbiology. However, data on some groups of microorganisms are still controversial. The aim of this study is to determine the utility of MALDI-TOF MS for the identification of clinical isolates of anaerobic bacteria. One-hundred and six anaerobic bacteria isolates were analyzed by MALDI-TOF MS and by conventional biochemical tests. In those cases where identification by conventional methodology was not applicable or in the face of discordance between sequencing methodologies, 16 S rRNA gene sequence analysis was performed. The conventional method and MALDI-TOF MS agreed at genus and species level by 95.3 %. Concordance in gram-negative bacilli was 91.4% and 100% among gram-positive bacilli; there was also concordance both in the 8 isolates studied in gram-positive cocci and in the single gram-negative cocci included. The data obtained in this study demonstrate that MALDI-TOF MS offers the possibility of adequate identification of anaerobic bacteria. Copyright © 2014 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  18. 2D-HPLC and MALDI-TOF/TOF analysis of barley proteins glycated during brewing

    Czech Academy of Sciences Publication Activity Database

    Petry-Podgorska, Inga; Žídková, Jitka; Flodrová, Dana; Bobálová, Janette

    2010-01-01

    Roč. 878, č. 30 (2010), s. 3143-3148 ISSN 1570-0232 R&D Projects: GA MŠk 1M0570 Institutional research plan: CEZ:AV0Z40310501 Keywords : 2D-HPLC * MALDI-TOF/TOF mass spectrometry * barley Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.971, year: 2010

  19. Towards Discovery and Targeted Peptide Biomarker Detection Using nanoESI-TIMS-TOF MS

    Energy Technology Data Exchange (ETDEWEB)

    Garabedian, Alyssa; Benigni, Paolo; Ramirez, Cesar; Baker, Erin M.; Liu, Tao; Smith, Richard D.; Fernandez-Lima, Francisco

    2018-05-01

    Abstract. In the present work, the potential of trapped ion mobility spectrometry coupled to TOF mass spectrometry (TIMS-TOF MS) for discovery and targeted monitoring of peptide biomarkers from human-in-mouse xenograft tumor tissue was evaluated. In particular, a TIMS-MS workflow was developed for the detection and quantification of peptide biomarkers using internal heavy analogs, taking advantage of the high mobility resolution (R = 150–250) prior to mass analysis. Five peptide biomarkers were separated, identified, and quantified using offline nanoESI-TIMSCID- TOF MS; the results were in good agreement with measurements using a traditional LC-ESI-MS/MS proteomics workflow. The TIMS-TOF MS analysis permitted peptide biomarker detection based on accurate mobility, mass measurements, and high sequence coverage for concentrations in the 10–200 nM range, while simultaneously achieving discovery measurements

  20. Les fondements de la mesure du temps comment les fréquences atomiques règlent le monde

    CERN Document Server

    Audoin, Claude

    1998-01-01

    La mesure du temps fondée sur des propriétés atomiques est née en 1955, avec le premier étalon de fréquence à jet de césium. Depuis, les horloges atomiques ne cessent de progresser et sont au coeur de nombreuses activités, telles que les comparaisons de temps, l'unification mondiale de l'heure ou la recherche en astronomie, géodésie, géophysique, télécommunications, etc. Cet ouvrage fournira des réponses détaillées au lecteur intéressé par la mesure du temps appliquée aux divers domaines cités.

  1. Mesures de procédure spéciales et respect des droits de l'homme
    Rapport général

    OpenAIRE

    John A.E. Vervaele

    2009-01-01

    Le but du rapport général est de mener une analyse comparative des rapports nationaux en vue de présenter les processus de transformation des systèmes de justice pénale internes, en particulier du procès pénal, étant donné que des mesures procédurales spéciales sont introduites pour appréhender le terrorisme et la criminalité organisée, et de voir si cela a conduit les pays à se départir de leur propres règles fondamentales, procédures, principes et standards des droits de l’homme applicables...

  2. La productivité et sa mesure en France (1944-1955)

    OpenAIRE

    Boulat, Régis

    2009-01-01

    Après la Deuxième Guerre mondiale, grâce à Jean Fourastié et aux modernisateurs du Plan, la productivité est reconnue par les élites et par l'opinion publique française comme « la clef » de la connaissance économique et le moteur de la croissance. Alors que la IVe République institutionnalise une politique d'accroissement de la prductivité dans le cadre d'un programme franco-américain de modernisation, la mesure de la productivité se perfectionne lentement grâce à l'affinement des mesures de ...

  3. MESUR metrics from scholarly usage of resources

    CERN Document Server

    CERN. Geneva; Van de Sompel, Herbert

    2007-01-01

    Usage data is increasingly regarded as a valuable resource in the assessment of scholarly communication items. However, the development of quantitative, usage-based indicators of scholarly impact is still in its infancy. The Digital Library Research & Prototyping Team at the Los Alamos National Laboratory's Research library has therefore started a program to expand the set of usage-based tools for the assessment of scholarly communication items. The two-year MESUR project, funded by the Andrew W. Mellon Foundation, aims to define and validate a range of usage-based impact metrics, and issue guidelines with regards to their characteristics and proper application. The MESUR project is constructing a large-scale semantic model of the scholarly community that seamlessly integrates a wide range of bibliographic, citation and usage data. Functioning as a reference data set, this model is analyzed to characterize the intricate networks of typed relationships that exist in the scholarly community. The resulting c...

  4. Study of gas mixtures and ageing of the multigap resistive plate chamber used for the ALICE TOF

    CERN Document Server

    Akindinov, A; Anselmo, F; Antonioli, P; Basile, M; Cara Romeo, G; Cifarelli, Luisa; Cindolo, F; Cosenza, F; D'Antone, I; De Caro, A; De Pasquale, S; Di Bartolomeo, A; Fusco-Girard, M; Golovine, V; Guerzoni, M; Guida, M; Hatzifotiadou, D; Kaidalov, A B; Kim, D H; Kim, D W; Kisselev, S M; Laurenti, G; Lioublev, E; Lee, K; Lee, S C; Luvisetto, M L; Margotti, A; Martemyanov, A N; Massera, F; Meneghini, S; Michinelli, R; Nania, R; Otiougova, P; Pancaldi, G; Pesci, A; Pilastrini, R; Pinazza, O; Polozov, P A; Rizzi, M; Scapparone, E; Scioli, G; Sellitto, S B; Semeria, F; Serra, S; Smirnitsky, A V; Tchoumakov, M M; Ugolini, E; Usenko, E; Valenti, G; Voloshin, K G; Williams, M C S; Zagreev, B V; Zampolli, C; Zichichi, A; Zucchini, A; Zuffa, M

    2004-01-01

    We present in this paper a study of the ALICE-TOF Multigap Resistive Plate Chamber (MRPC) performance by using several gas mixtures. We also present a search for possible ageing effects, by studying two MRPCs irradiated at the CERN Gamma Irradiation Facility.

  5. The performance of TOF near backscattering spectrometer DNA in MLF, J-PARC

    International Nuclear Information System (INIS)

    Shibata, Kaoru; Kawakita, Yukinobu; Kambara, Wataru; Inamura, Yasuhiro; Nakatani, Takeshi; Nakajima, Kenji; Arai, Masatoshi; Takahashi, Nobuaki; Matsuura, Masato; Yamada, Takeshi; Tominaga, Taiki; Kobayashi, Makoto

    2015-01-01

    The time-of-flight (TOF) type near-backscattering spectrometer (n-BSS), DNA, with Si crystal analyzers was built and started operation in 2012 at the Materials and Life Science Experimental Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC). DNA is the first n-BSS with pulse shaping chopper installed at a spallation pulsed neutron source. It offers currently the highest energy-resolution of about 2.4 micro eV by operating a pulse shaping double-disk chopper at 225 Hz whose phase is optimized to the narrowest slit of 10 mm width. Energy resolution can be flexibly compromised with intensity during experiment by using two type slits with different widths and changing the copper frequency. An example of measurement with high energy-resolution under the condition that the pulse shaping chopper was operated is shown, where the limited measurable energy range was widely expanded by multi incident energy band technique. The experimental data demonstrate extremely high signal-to-noise ratio (∼10"5) of this spectrometer. (author)

  6. Towards Discovery and Targeted Peptide Biomarker Detection Using nanoESI-TIMS-TOF MS

    Science.gov (United States)

    Garabedian, Alyssa; Benigni, Paolo; Ramirez, Cesar E.; Baker, Erin S.; Liu, Tao; Smith, Richard D.; Fernandez-Lima, Francisco

    2017-09-01

    In the present work, the potential of trapped ion mobility spectrometry coupled to TOF mass spectrometry (TIMS-TOF MS) for discovery and targeted monitoring of peptide biomarkers from human-in-mouse xenograft tumor tissue was evaluated. In particular, a TIMS-MS workflow was developed for the detection and quantification of peptide biomarkers using internal heavy analogs, taking advantage of the high mobility resolution (R = 150-250) prior to mass analysis. Five peptide biomarkers were separated, identified, and quantified using offline nanoESI-TIMS-CID-TOF MS; the results were in good agreement with measurements using a traditional LC-ESI-MS/MS proteomics workflow. The TIMS-TOF MS analysis permitted peptide biomarker detection based on accurate mobility, mass measurements, and high sequence coverage for concentrations in the 10-200 nM range, while simultaneously achieving discovery measurements of not initially targeted peptides as markers from the same proteins and, eventually, other proteins. [Figure not available: see fulltext.

  7. Measurement of the (33)S(n,α) cross-section at n_TOF(CERN): Applications to BNCT.

    Science.gov (United States)

    Sabaté-Gilarte, Marta; Praena, Javier; Porras, Ignacio; Quesada, José Manuel; Mastinu, Pierfrancesco

    2016-01-01

    The main purpose of this work is to present a new (n,α) cross-section measurement for a stable isotope of sulfur, (33)S, in order to solve existing discrepancies. (33)S has been studied as a cooperating target for Boron Neutron Capture Therapy (BNCT) because of its large (n,α) cross-section in the epithermal neutron energy range, the most suitable one for BNCT. Although the most important evaluated databases, such as ENDF, do not show any resonances in the cross-section, experimental measurements which provided data from 10 keV to 1 MeV showed that the lowest-lying and strongest resonance of (33)S(n,α) cross-section occurs at 13.5 keV. Nevertheless, the set of resonance parameters that describe such resonance shows important discrepancies (more than a factor of 2) between them. A new measurement of the (33)S(n,α)(30)Si reaction cross-section was proposed to the ISOLDE and Neutron Time-of-Flight Experiments Committee of CERN. It was performed at n_TOF(CERN) in 2012 using MicroMegas detectors. In this work, we will present a brief overview of the experiment as well as preliminary results of the data analysis in the neutron energy range from thermal to 100 keV. These results will be taken into account to calculate the kerma-fluence factors corresponding to (33)S in addition to (10)B and those of a standard four-component ICRU tissue. MCNP simulations of the deposited dose, including our experimental data, shows an important kerma rate enhancement at the surface of the tissue, mainly due to the presence of (33)S.

  8. Dispositif de mesure de pertes dans les conducteurs supraconducteurs utilisés en régime variable

    Science.gov (United States)

    Le Naour, S.; Lacaze, A.; Laumond, Y.

    1998-01-01

    A thermometric apparatus to measure AC losses in superconductor wires for 50 Hz applications is described. This method consists in isolating the sample from a helium bath via a thermal resistance. Dissipated power is determined by two thermometers located on both edges of a thermal resistance. The measurement's calibration is done using an ohmic heater. The measurement accuracy is 10% for losses in excess of 2 mW/m. Un dispositif expérimental, pour mesurer les pertes générées dans les conducteurs supraconducteurs utilisés en régime alternatif 50 Hz, est décrit. La méthode, basée sur le principe thermométrique, consiste à isoler l'échantillon du bain d'hélium par une résistance thermique. La puissance dissipée est déterminée à l'aide de deux sondes de température disposées de part et d'autre de la résistance. L'étalonnage de la mesure est assuré par une chaufferette. La précision des mesures est de 10% pour des pertes linéiques supérieures à 2 mW/m.

  9. Fast measure proceeding of weak currents; Un procede de mesure rapide des courants faibles

    Energy Technology Data Exchange (ETDEWEB)

    Taieb, J [Commissariat a l' Energie Atomique, Siege (France). Centre d' Etudes Nucleaires

    1953-07-01

    The process of fast measure of the weak currents that we are going to describe briefly apply worthy of the provided currents by the sources to elevated value internal resistance, as it is the case for the ionization chamber, the photocells, mass spectroscopic tubes. The problem to measure weak currents is essentially a problem of amplifier and of input circuit. We intended to achieve a whole amplifier and input circuit with advanced performances, meaning that for a measured celerity we wanted to have an signal/noise ratio the most important as in the classic systems and for a same report signal/noise a more quickly done measure. (M.B.) [French] Le procede de mesure rapide des courants faibles que nous allons brievement decrire s'applique a la mesure des courants fournis par les sources a resistance interne de valeur elevee, comme c'est le cas pour les chambres d'ionisation, les photocellules, les tubes de spectrographe de masse. Le probleme de mesure de courants faibles est essentiellement un probleme d'amplificateur et de circuit d'entree. Nous nous sommes proposes de realiser un ensemble amplificateur et circuit d'entree a performances poussees, c'est a dire que pour une meme rapidite de mesure nous desirions avoir un rapport signal/bruit plus important que dans les systemes classiques et pour un meme rapport signal/bruit une mesure effectuee plus rapidement. (M.B.)

  10. Les mesures de gel et de confiscation en vertu de la Loi sur les embargos

    OpenAIRE

    Schnyder, Nicolas

    2009-01-01

    Etude du mécanisme d'adoption des mesures de gel et de confiscation en vertu de la Loi sur les embargos et leurs conséquences tant sur la personne principalement touchée par ces mesures que sur les tiers.

  11. Perceptions locales du changement climatique et mesures d ...

    African Journals Online (AJOL)

    Perceptions locales du changement climatique et mesures d'adaptation dans la ... village, de l'importance représentée par le karité pour les groupes socioculturels. ... l'adaptation de nouvelles cultures en association, la protection des jeunes ...

  12. Mesurer en réseau d'assainissement pour quoi faire ?

    OpenAIRE

    LAPLACE, Dominique; JOANNIS, Claude; GUIVARCH, Jean Yves

    2009-01-01

    La mesure de pluie, de niveau d'eau, de vitesse, de débit ou encore de pollution en réseau d'assainissement répond essentiellement à des besoins de contrôle du bon fonctionnement du système, de compréhension et d'amélioration de ces réseaux et d'information des différents acteurs impliqués. Associée à un dispositif de gestion en temps la mesure contribue à permettre de surveiller et maîtriser le fonctionnement du réseau par temps sec et par temps de pluie, et de piloter des actionneurs (pompe...

  13. Timing resolution improvement using DOI information in a four-layer scintillation detector for TOF-PET

    Energy Technology Data Exchange (ETDEWEB)

    Shibuya, Kengo [jPET Project Team, Molecular Imaging Center, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage-ku, Chiba 263-0024 (Japan)], E-mail: shibuken@gakushikai.jp; Nishikido, Fumihiko [jPET Project Team, Molecular Imaging Center, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage-ku, Chiba 263-0024 (Japan); Tsuda, Tomoaki [Technology Research Laboratory, Shimadzu Corporation, Hikaridai 3-9-4, Seika-cho, Kyoto 619-0237 (Japan); Kobayashi, Tetsuya [Department of Medical System Engineering, Graduate School of Engineering, Chiba University, Yayoi 1-33, Inage-ku, Chiba 263-8522 (Japan); Lam, Chihfung; Yamaya, Taiga; Yoshida, Eiji; Inadama, Naoko; Murayama, Hideo [jPET Project Team, Molecular Imaging Center, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage-ku, Chiba 263-0024 (Japan)

    2008-08-11

    Depth-of-interaction (DOI) detectors are considered to be advantageous for time-of-flight positron emission tomography (TOF-PET) because they can correct timing errors arising in the scintillation crystals due to a propagation speed difference between annihilation radiation and scintillation photons. We experimentally measured this timing error, using our four-layer DOI encoding method. The upper layers exhibited the larger timing delays due to the longer path lengths after conversion from annihilation radiation into scintillation photons that traveled by zigzag paths at a speed decreased by a factor of the refractive index (n). The maximum timing delay between the uppermost and the lowermost layers was evaluated as 164 ps when n=1.47. A TOF error correction was demonstrated to improve the timing resolution of the four-layer DOI detector by 10.3%, which would increase the effective sensitivity of the scanner by about 12% comparison with a non-DOI TOF-PET scanner. This is the first step towards combining these two important fields in PET instrumentation, namely DOI and TOF, for the purpose of achieving a higher sensitivity as well as a more uniform spatial resolution.

  14. MESUR: metrics from scholarly usage of resources

    CERN Multimedia

    CERN. Geneva

    2007-01-01

    The MESUR project is constructing a large-scale semantic model of the scholarly community that seamlessly integrates a wide range of bibliographic, citation and usage data. Functioning as a reference data set, this model is analyzed to characterize the intricate networks of typed relationships that exist in the scholarly community. The resulting ...

  15. Investigating the microstructure of keratin extracted from wool: peptide sequence (MALDI-TOF/TOF) and protein conformation (FTIR)

    Science.gov (United States)

    Keratin was extracted from wool by reduction with 2-mercaptoethanol. It was isolated as intact keratin and characterized by its similar molecular weight, protein composition, and secondary structure to native keratin. Gel electrophoresis patterns and MALDI-TOF/TOF peptide sequences provided the ide...

  16. High-dynamic-range neutron time-of-flight detector used to infer the D(t,n){sup 4}He and D(d,n){sup 3}He reaction yield and ion temperature on OMEGA

    Energy Technology Data Exchange (ETDEWEB)

    Forrest, C. J., E-mail: cforrest@lle.rochester.edu; Glebov, V. Yu.; Goncharov, V. N.; Knauer, J. P.; Radha, P. B.; Regan, S. P.; Romanofsky, M. H.; Sangster, T. C.; Shoup, M. J.; Stoeckl, C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623-1299 (United States)

    2016-11-15

    Upgraded microchannel-plate–based photomultiplier tubes (MCP-PMT’s) with increased stability to signal-shape linearity have been implemented on the 13.4-m neutron time-of-flight (nTOF) detector at the Omega Laser Facility. This diagnostic uses oxygenated xylene doped with diphenyloxazole C{sub 15}H{sub 11}NO + p-bis-(o-methylstyryl)-benzene (PPO + bis-MSB) wavelength shifting dyes and is coupled through four viewing ports to fast-gating MCP-PMT’s, each with a different gain to allow one to measure the light output over a dynamic range of 1 × 10{sup 6}. With these enhancements, the 13.4-m nTOF can measure the D(t,n){sup 4}He and D(d,n){sup 3}He reaction yields and average ion temperatures in a single line of sight. Once calibrated for absolute neutron sensitivity, the nTOF detectors can be used to measure the neutron yield from 1 × 10{sup 9} to 1 × 10{sup 14} and the ion temperature with an accuracy approaching 5% for both the D(t,n){sup 4}He and D(d,n){sup 3}He reactions.

  17. Topochemical Analysis of Cell Wall Components by TOF-SIMS.

    Science.gov (United States)

    Aoki, Dan; Fukushima, Kazuhiko

    2017-01-01

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a recently developing analytical tool and a type of imaging mass spectrometry. TOF-SIMS provides mass spectral information with a lateral resolution on the order of submicrons, with widespread applicability. Sometimes, it is described as a surface analysis method without the requirement for sample pretreatment; however, several points need to be taken into account for the complete utilization of the capabilities of TOF-SIMS. In this chapter, we introduce methods for TOF-SIMS sample treatments, as well as basic knowledge of wood samples TOF-SIMS spectral and image data analysis.

  18. Measurement of the 33S(n,α) cross-section at n_TOF(CERN): Applications to BNCT

    Science.gov (United States)

    Sabaté-Gilarte, Marta; Praena, Javier; Porras, Ignacio; Quesada, José Manuel; Mastinu, Pierfrancesco

    2016-01-01

    Aim The main purpose of this work is to present a new (n,α) cross-section measurement for a stable isotope of sulfur, 33S, in order to solve existing discrepancies. Background 33S has been studied as a cooperating target for Boron Neutron Capture Therapy (BNCT) because of its large (n,α) cross-section in the epithermal neutron energy range, the most suitable one for BNCT. Although the most important evaluated databases, such as ENDF, do not show any resonances in the cross-section, experimental measurements which provided data from 10 keV to 1 MeV showed that the lowest-lying and strongest resonance of 33S(n,α) cross-section occurs at 13.5 keV. Nevertheless, the set of resonance parameters that describe such resonance shows important discrepancies (more than a factor of 2) between them. Materials and methods A new measurement of the 33S(n,α)30Si reaction cross-section was proposed to the ISOLDE and Neutron Time-of-Flight Experiments Committee of CERN. It was performed at n_TOF(CERN) in 2012 using MicroMegas detectors. Results In this work, we will present a brief overview of the experiment as well as preliminary results of the data analysis in the neutron energy range from thermal to 100 keV. These results will be taken into account to calculate the kerma-fluence factors corresponding to 33S in addition to 10B and those of a standard four-component ICRU tissue. Conclusions MCNP simulations of the deposited dose, including our experimental data, shows an important kerma rate enhancement at the surface of the tissue, mainly due to the presence of 33S. PMID:26933393

  19. MALDI-TOF and SELDI-TOF analysis: “tandem” techniques to identify potential biomarker in fibromyalgia

    Directory of Open Access Journals (Sweden)

    A. Lucacchini

    2011-11-01

    Full Text Available Fibromyalgia (FM is characterized by the presence of chronic widespread pain throughout the musculoskeletal system and diffuse tenderness. Unfortunately, no laboratory tests have been appropriately validated for FM and correlated with the subsets and activity. The aim of this study was to apply a proteomic technique in saliva of FM patients: the Surface Enhance Laser Desorption/Ionization Time-of-Flight (SELDI-TOF. For this study, 57 FM patients and 35 HC patients were enrolled. The proteomic analysis of saliva was carried out using SELDI-TOF. The analysis was performed using different chip arrays with different characteristics of binding. The statistical analysis was performed using cluster analysis and the difference between two groups was underlined using Student’s t-test. Spectra analysis highlighted the presence of several peaks differently expressed in FM patients compared with controls. The preliminary results obtained by SELDI-TOF analysis were compared with those obtained in our previous study performed on whole saliva of FM patients by using electrophoresis. The m/z of two peaks, increased in FM patients, seem to overlap well with the molecular weight of calgranulin A and C and Rho GDP-dissociation inhibitor 2, which we had found up-regulated in our previous study. These preliminary results showed the possibility of identifying potential salivary biomarker through salivary proteomic analysis with MALDI-TOF and SELDI-TOF in FM patients. The peaks observed allow us to focus on some of the particular pathogenic aspects of FM, the oxidative stress which contradistinguishes this condition, the involvement of proteins related to the cytoskeletal arrangements, and central sensibilization.

  20. MESUR: USAGE-BASED METRICS OF SCHOLARLY IMPACT

    Energy Technology Data Exchange (ETDEWEB)

    BOLLEN, JOHAN [Los Alamos National Laboratory; RODRIGUEZ, MARKO A. [Los Alamos National Laboratory; VAN DE SOMPEL, HERBERT [Los Alamos National Laboratory

    2007-01-30

    The evaluation of scholarly communication items is now largely a matter of expert opinion or metrics derived from citation data. Both approaches can fail to take into account the myriad of factors that shape scholarly impact. Usage data has emerged as a promising complement to existing methods o fassessment but the formal groundwork to reliably and validly apply usage-based metrics of schlolarly impact is lacking. The Andrew W. Mellon Foundation funded MESUR project constitutes a systematic effort to define, validate and cross-validate a range of usage-based metrics of schlolarly impact by creating a semantic model of the scholarly communication process. The constructed model will serve as the basis of a creating a large-scale semantic network that seamlessly relates citation, bibliographic and usage data from a variety of sources. A subsequent program that uses the established semantic network as a reference data set will determine the characteristics and semantics of a variety of usage-based metrics of schlolarly impact. This paper outlines the architecture and methodology adopted by the MESUR project and its future direction.

  1. Above-ground tree outside forest (TOF) phytomass and carbon ...

    Indian Academy of Sciences (India)

    to classify TOF, to estimate above-ground TOF phytomass and the carbon content ... eral, trees outside forests (TOF) mean the trees ..... have been used to stratify the area, based on the ... The optimum plot size and num- .... population centres.

  2. Shortcomings of the Commercial MALDI-TOF MS Database and Use of MLSA as an Arbiter in the Identification of Nocardia Species

    Science.gov (United States)

    Carrasco, Gema; de Dios Caballero, Juan; Garrido, Noelia; Valdezate, Sylvia; Cantón, Rafael; Sáez-Nieto, Juan A.

    2016-01-01

    Nocardia species are difficult to identify, a consequence of the ever increasing number of species known and their homogeneous genetic characteristics. 16S rRNA analysis has been the gold standard for identifying these organisms, but proteomic techniques such as matrix-assisted laser desorption ionization-time of flight (MALDI-TOF MS) and housekeeping gene analysis, have also been explored. One hundred high (n = 25), intermediate (n = 20), and low (n = 55) prevalence (for Spain) Nocardia strains belonging to 30 species were identified via 16S rRNA and MALDI-TOF MS analysis. The manufacturer-provided database MALDI Biotyper library v4.0 (5.627 entries, Bruker Daltonik) was employed. In the high prevalence group (Nocardia farcinica, N. abscessus, N. cyriacigeorgica and N. nova), the 16S rRNA and MALDI-TOF MS methods provided the same identification for 76% of the strains examined. For the intermediate prevalence group (N. brasiliensis, N. carnea, N. otitidiscaviarum and N. transvalensis complex), this figure fell to 45%. In the low-prevalence group (22 species), these two methods were concordant only in six strains at the species level. Tetra-gene multi-locus sequencing analysis (MLSA) involving the concatemer gyrB-16S rRNA-hsp65-secA1 was used to arbitrate between discrepant identifications (n = 67). Overall, the MLSA confirmed the results provided at species level by 16S rRNA analysis in 34.3% of discrepancies, and those provided by MALDI-TOF MS in 13.4%. MALDI-TOF MS could be a strong candidate for the identification of Nocardia species, but only if its reference spectrum database improves, especially with respect to unusual, recently described species and species included in the described Nocardia complexes. PMID:27148228

  3. DOSE EFFECT OF THE 33S(n,α) 30SI REACTION IN BNCT USING THE NEW n_TOF-CERN DATA.

    Science.gov (United States)

    Sabaté-Gilarte, M; Praena, J; Porras, I; Quesada, J M

    2017-09-23

    33S is a stable isotope of sulphur which is being studied as a potential cooperative target for Boron Neutron Capture Therapy (BNCT) in accelerator-based neutron sources because of its large (n,α) cross section in the epithermal neutron energy range. Previous measurements resolved the resonances with a discrepant description of the lowest-lying and strongest one (at 13.5 keV). However, the evaluations of the major databases do not include resonances, except EAF-2010 which shows smaller values in this range than the experimental data. Furthermore, the glaring lack of data below 10 keV down to thermal (25.3 meV) has motivated a new measurement at n_TOF at CERN in order to cover the whole energy range. The inclusion of this new 33S(n,α) cross section in Monte Carlo simulations provides a more accurate estimation of the deposited kerma rate in tissue due to the presence of 33S. The results of those simulations represent the goal of this work. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Upgrade and development of nuclear data production test facility

    Energy Technology Data Exchange (ETDEWEB)

    Namkung, Won; Ko, I. S.; Cho, M. H.; Lee, Y. S.; Kang, H. S. [Pohang Univ. of Science and Technology, Pohang (Korea, Republic of); Kim, G. N. [Kyungpook National Univ., Daegu (Korea, Republic of); Koh, S. K. [Univ. of Ulsan, Ulsan (Korea, Republic of); Ro, T. I. [Donga Univ., Busan (Korea, Republic of); Choi, G. U. [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2005-04-15

    It is necessary to improve the Pohang Neutron Facility (PNF) in order to be used as a nuclear data production facility for users in both domestic and abroad. We improved following items: upgrade the electron linac, collimators inside the TOF beam pipe, the development and installation of an automatic sample changer, the extension of the TOF beam line, and the data acquisition system. We would like to establish a utilization system for users to measure the nuclear data at the PNF. To do this, we made manuals for the accelerator operation and the data acquisition system. We also made an application form to apply for users to measure the nuclear data in both domestic and abroad. The main object of the Pohang Neutron Facility is to measure the nuclear data in the neutron energy region from thermal neutron to few hundreds of eV. In addition to neutron beams produced at the PNF, photon and electron beams are produced in this facility. We thus utilize this facility for other fields, such as test facility for detectors, activation experiments, polarized neutron beam source, and so on. In addition to these, we could use this facility for training students.

  5. The WNR facility - a pulsed spallation neutron source at the Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Russell, G.J.; Lisowski, P.W.; King, N.S.P.

    1978-01-01

    The Weapons Neutron Research facility (WNR) at the Los Alamos Scientific Laboratory is the first operating example of a new class of pulsed neutron sources using the X(p,n)Y spallation reaction. At present, up to 10 microamperes of 800-MeV protons from the Clinton P. Anderson Meson Physics Facility (LAMPF) linear accelerator bombard a Ta target to produce an intense white-neutron spectrum from about 800 MeV to 100 keV. The Ta target can be coupled with CH 2 and H 2 O moderators to produce neutrons of lower energy. The time structure of the WNR proton beam may be varied to optimize neutron time-of-flight (TOF) measurements covering the energy range from several hundred MeV to a few meV. The neutronics of the WNR target and target/moderator configurations have been calculated from 800 MeV to 0.5 eV. About 11 neutrons per proton are predicted for the existing Ta target. Some initial neutron TOF data are presented and compared with calculations

  6. Shortcomings of of the commercial MALDI-TOF MS database and use of MLSA as an arbiter in the identification of Nocardia species

    Directory of Open Access Journals (Sweden)

    Gema eCarrasco

    2016-04-01

    Full Text Available Nocardia species are difficult to identify, a consequence of the ever increasing number of species known and their homogeneous genetic characteristics. 16S rRNA analysis has been the gold standard for identifying these organisms, but proteomic techniques such as matrix-assisted laser desorption ionization-time of flight (MALDI-TOF MS and housekeeping gene analysis, have also been explored. One hundred high (n=25, intermediate (n=20 and low (n=55 prevalence (for Spain Nocardia strains belonging to 30 species were identified via 16S rRNA and MALDI-TOF MS analysis. The manufacturer-provided database MALDI Biotyper library v4.0 (5.627 entries, Bruker Daltonik was employed. In the high prevalence group (N. farcinica, N. abscessus, N. cyriacigeorgica and N. nova, the 16S rRNA and MALDI-TOF MS methods provided the same identification for 76% of the strains examined. For the intermediate prevalence group (N. brasiliensis, N. carnea, N. otitidiscaviarum and N. transvalensis complex, this figure fell to 45%. In the low-prevalence group (22 species, these two methods were concordant only in six strains at the species level. Tetra-gene multi-locus sequencing analysis (MLSA involving the concatemer gyrB-16S rRNA-hsp65-secA1 was used to arbitrate between discrepant identifications (n=67. Overall, the MLSA confirmed the results provided at species level by 16S rRNA analysis in 34.3% of discrepancies, and those provided by MALDI-TOF MS in 13.4%. MALDI-TOF MS could be a strong candidate for the identification of Nocardia species, but only if its reference spectrum database improves, especially with respect to unusual, recently described species and species included in the described Nocardia complexes.

  7. MALDI-TOF and cluster-TOF-SIMS imaging of Fabry disease biomarkers

    Science.gov (United States)

    Touboul, David; Roy, Sandrine; Germain, Dominique P.; Chaminade, Pierre; Brunelle, Alain; Laprevote, Olivier

    2007-02-01

    Fabry disease is an X-linked disorder of glycosphingolipid metabolism, in which a partial or total deficiency of [alpha]-galactosidase A, a lysosomal enzyme, results in the progressive accumulation of neutral glycosphingolipids (globotriaosylceramide and digalactosylceramide) in most fluids and tissues of the body. Few information is available about the composition and distribution in tissues of the accumulated glycosphingolipids species. Mass spectrometry imaging is an innovative technique, which can provide pieces of information about the distribution of numerous biological compounds, such as lipids, directly on the tissue sections. MALDI-TOF and cluster-TOF-SIMS imaging approaches were used to study the localization of lipids (cholesterol, cholesterol sulfate, vitamin E, glycosphingolipids ...) on skin and kidney sections of patients affected by the Fabry disease. Numerous information on pathophysiology were enlightened by both techniques.

  8. Measurement of the C / H ratio using neutrons; Mesure du rapport C / H au moyen des neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Martinelli, P [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Ricci, H [Universite de Lima (Peru)

    1960-07-01

    A probe made up of a Ra ({alpha}, n) Be neutron source and a proportional counter filled with boron trifluoride has been used to measure the C/H ratio in hydrocarbons. The intensity of the thermal neutron flux in the neighbourhood of the detector increases with the concentration of the hydrocarbon hydrogen surrounding it. By measuring the density it is possible to deduce the C/H ratio. It is thus possible to evaluate the C/H ratio with a precision equal to that given by the {beta}-ray transmission method. The errors arising from the chemical nature of the hydrocarbon can be reduced to a minimum. This method has the advantage of allowing the measurement of the C/H ratio of hydrocarbons contained in recipients or thick steel tubing by means an independent portable apparatus. (author) [French] Une sonde constituee d'une source de neutrons Ra ({alpha}, n) Be et d'un compteur proportionnel a remplissage de trifluorure de bore a ete utilisee pour mesurer le rapport C/H dans les hydrocarbures. Le flux des neutrons thermiques au voisinage du detecteur est d'autant plus intense que la concentration en hydrogene de l'hydrocarbure qui entoure la sonde est plus elevee. Une mesure de densite permet d'en deduire le rapport C/H. On peut ainsi evaluer le rapport C/H avec une precision aussi bonne que celle que l'on obtient par transmission de rayons {beta}. Les erreurs provenant de la nature chimique de l'hydrocarbure peuvent etre minimisees. Cette methode presente l'avantage de permettre la mesure du rapport C/H d'hydrocarbures contenus dans des recipients ou des canalisations epaisses en acier a l'aide d'un appareil exterieur transportable. (auteur)

  9. An instrument for measuring doubling time; Un appareillage de mesure de temps de doublement

    Energy Technology Data Exchange (ETDEWEB)

    Ailloud, J; Chandanson, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    The instrument described here allows the direct and almost immediate measurement, with a precision of the order of 1 per cent, of the time taken by a reactor to double its power. The method of measurement consists of noting the instants when the power of the reactor passes the levels P{sub 1} and P{sub 2} such that P{sub 2} = 2 P{sub 1}, and of measuring the time lapse between these two instants. The instrument picks out, in the course of one rise in power, several levels, P{sub 1}, P{sub 2}, P{sub 3}... etc, chosen in such a manner as to give several successive measurements of the doubling time. It is also capable of making these same measurements when the reactor is working below the critical level. (author) [French] L'appareil decrit ici permet la mesure directe et quasi immediate du temps de doublement de la puissance d'un reacteur avec une precision de l'ordre de 1 pour cent. La methode de mesure consiste a reperer les instants de passage de la puissance du reacteur par des niveaux P{sub 1} et P{sub 2} tels que P{sub 2} = 2 P{sub 1}, et a mesurer le temps ecoule entre ces deux instants. L'appareil repere, au cours d'une meme montee en puissance, plusieurs niveaux, P{sub 1}, P{sub 2}, P{sub 3}... etc, choisis de maniere a donner plusieurs mesures successives du temps de doublement. Il est egalement utilisable pour effectuer ces memes mesures lorsque le reacteur est en regime sous-critique. (auteur)

  10. Integral measurement of the $^{12}$C(n,p)$^{12}$B reaction up to 10 GeV

    CERN Document Server

    Žugec, P; Bosnar, D; Ventura, A; Mengoni, A; Altstadt, S; Andrzejewski, J; Audouin, L; Barbagallo, M; Bécares, V; Bečvář, F; Belloni, F; Berthoumieux, E; Billowes, J; Boccone, V; Brugger, M; Calviani, M; Calviño, F; Cano-Ott, D; Carrapiço, C; Cerutti, F; Chiaveri, E; Chin, M; Cortés, G; Cortés-Giraldo, M.A; Cosentino, L; Diakaki, M; Domingo-Pardo, C; Dressler, R; Duran, I; Eleftheriadis, C; Ferrari, A; Finocchiaro, P; Fraval, K; Ganesan, S; García, A R; Giubrone, G; Gómez-Hornillos, M B; Gonçalves, I F; González-Romero, E; Griesmayer, E; Guerrero, C; Gunsing, F; Gurusamy, P; Heinitz, S; Jenkins, D G; Jericha, E; Käppeler, F; Karadimos, D; Kivel, N; Kokkoris, M; Krtička, M; Kroll, J; Langer, C; Lederer, C; Leeb, H; Leong, L S; Meo, S Lo; Losito, R; Manousos, A; Marganiec, J; Martínez, T; Massimi, C; Mastinu, P; Mastromarco, M; Mendoza, E; Milazzo, P M; Mingrone, F; Mirea, M; Mondalaers, W; Musumarra, A; Paradela, C; Pavlik, A; Perkowski, J; Plompen, A; Praena, J; Quesada, J; Rauscher, T; Reifarth, R; Riego, A; Roman, F; Rubbia, C; Sarmento, R; Saxena, A; Schillebeeckx, P; Schmidt, S; Schumann, D; Tagliente, G; Tain, J L; Tarrío, D; Tassan-Got, L; Tsinganis, A; Valenta, S; Vannini, G; Variale, V; Vaz, P; Versaci, R; Vermeulen, M J; Vlachoudis, V; Vlastou, R; Wallner, A; Ware, T; Weigand, M; Weiß, C; Wright, T

    2016-01-01

    The integral measurement of the $^{12}$C(n,p)$^{12}$B reaction was performed at the neutron time of flight facility n_TOF at CERN. The total number of $^{12}$B nuclei produced per neutron pulse of the n_TOF beam was determined using the activation technique in combination with a time of flight technique. The cross section is integrated over the n_TOF neutron energy spectrum from reaction threshold at 13.6 MeV to 10 GeV. Having been measured up to 1 GeV on basis of the $^{235}$U(n,f) reaction, the neutron energy spectrum above 200 MeV has been reevaluated due to the recent extension of the cross section reference for this particular reaction, which is otherwise considered a standard up to 200 MeV. The results from the dedicated GEANT4 simulations have been used to evaluate the neutron flux from 1 GeV up to 10 GeV. The experimental results related to the $^{12}$C(n,p)$^{12}$B reaction are compared with the evaluated cross sections from major libraries and with the predictions of different GEANT4 models, which m...

  11. Experimental design for optimizing MALDI-TOF-MS analysis of palladium complexes

    Directory of Open Access Journals (Sweden)

    Rakić-Kostić Tijana M.

    2017-01-01

    Full Text Available This paper presents optimization of matrix-assisted laser desorption/ionization (MALDI time-of-flight (TOF mass spectrometer (MS instrumental parameters for the analysis of chloro(2,2'',2"-terpyridinepalladium(II chloride dihydrate complex applying design of experiments methodology (DoE. This complex is of interest for potential use in the cancer therapy. DoE methodology was proved to succeed in optimization of many complex analytical problems. However, it has been poorly used for MALDI-TOF-MS optimization up to now. The theoretical mathematical relationships which explain the influence of important experimental factors (laser energy, grid voltage and number of laser shots on the selected responses (signal to noise – S/N ratio and the resolution – R of the leading peak is established. The optimal instrumental settings providing maximal S/N and R are identified and experimentally verified. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 172052 and Grant no. 172011

  12. The (n, $\\gamma$) reaction in the s-process branching point $^{59}$Ni

    CERN Multimedia

    We propose to measure the $^{59}$Ni(n,$\\gamma$)$^{56}$Fe cross section at the neutron time of flight (n TOF) facility with a dedicated chemical vapor deposition (CVD) diamond detector. The (n, ) reaction in the radioactive $^{59}$Ni is of relevance in nuclear astrophysics as it can be seen as a rst branching point in the astrophysical s-process. Its relevance in nuclear technology is especially related to material embrittlement in stainless steel. There is a strong discrepancy between available experimental data and the evaluated nuclear data les for this isotope. The aim of the measurement is to clarify this disagreement. The clear energy separation of the reaction products of neutron induced reactions in $^{59}$Ni makes it a very suitable candidate for a rst cross section measurement with the CVD diamond detector, which should serve in the future for similar measurements at n_TOF.

  13. NINO ASIC electronics used in MRPC/TOF experiment

    International Nuclear Information System (INIS)

    Sun Yongjie; Li Cheng

    2008-01-01

    In order to meet the excellent properties of MRPC, an front-end amplifier/discriminator chip-NINO ASIC, was developed in ALICE TOF group at CERN. This ASIC was fabricated with the 0.25 μm CMOS technology. It is highly integrated and can deal with 8 channels per chip. It has differential input and is differential signal shaping and throughout transition. The peaking time of the amplifier is less than 1 ns. It has LVDS outputs and the width of the output signal depended on the charge of input. This allows the TOT measurement of HPTDC system. A position sensitive MRPC was tested with beam facility using the front-end electronics based on NINO and good results were obtained. (authors)

  14. Development of a detector in order to investigate (n,γ)-cross sections by ToF method with a very short flight path

    Science.gov (United States)

    Wolf, C.; Glorius, J.; Reifarth, R.; Weigand, M.

    2018-01-01

    The determination of neutron capture cross sections of some radioactive isotopes like 85Kr is very important to improve the knowledge about the s process. Based on its own radioactive decay these isotopes can only be used in small samples inside a TOF facility, which is why the neutron flux of these facilities has to be very high. Unfortunately the neutron flux of the FRANZ setup at Goethe University Frankfurt, which will offer the highest neutron flux in astrophysical energy regions (keV region) [1], is still to low to investigate isotopes like 85Kr. Therefore a new setup called NAUTILUS is under development, which will reduce the flight path from 80 cm to a few centimeter to enhance the angular coverage of the sample and therefore increase the neutron flux by a factor of nearly 100. This implies a higher intensity of the γ-flash energy inside the detector and the neutron induced background. Hence the geometry, the scintillator material and the moderator were optimized by GEANT3 simulations.

  15. Upgrade and Development of Nuclear Data Production Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-04-15

    It is necessary to improve the Pohang Neutron Facility (PNF) in order to be used as a nuclear data production facility for users in both domestic and abroad. We improved following items: (1) upgrade the electron linac, (2) collimators inside the TOF beam pipe, (3) the development and installation of an automatic sample changer, (4) the extension of the TOF beam line, and (5) the data acquisition system. We would like to establish a utilization system for users to measure the nuclear data at the PNF. To do this, we made manuals for the accelerator operation and the data acquisition system. We also made an application form to apply for users to measure the nuclear data in both domestic and abroad. The main object of the Pohang Neutron Facility is to measure the nuclear data in the neutron energy region from thermal neutron to few hundreds of eV. In addition to neutron beams produced at the PNF, photon and electron beams are produced in this facility. We thus utilize this facility for other fields, such as test facility for detectors, activation experiments, polarized neutron beam source, and so on. In addition to these, we could use this facility for training students

  16. Mesure et retroaction sur un qubit multi-niveaux en electrodynamique quantique en circuit non lineair

    Science.gov (United States)

    Boissonneault, Maxime

    L'electrodynamique quantique en circuit est une architecture prometteuse pour le calcul quantique ainsi que pour etudier l'optique quantique. Dans cette architecture, on couple un ou plusieurs qubits supraconducteurs jouant le role d'atomes a un ou plusieurs resonateurs jouant le role de cavites optiques. Dans cette these, j'etudie l'interaction entre un seul qubit supraconducteur et un seul resonateur, en permettant cependant au qubit d'avoir plus de deux niveaux et au resonateur d'avoir une non-linearite Kerr. Je m'interesse particulierement a la lecture de l'etat du qubit et a son amelioration, a la retroaction du processus de mesure sur le qubit de meme qu'a l'etude des proprietes quantiques du resonateur a l'aide du qubit. J'utilise pour ce faire un modele analytique reduit que je developpe a partir de la description complete du systeme en utilisant principalement des transfprmations unitaires et une elimination adiabatique. J'utilise aussi une librairie de calcul numerique maison permettant de simuler efficacement l'evolution du systeme complet. Je compare les predictions du modele analytique reduit et les resultats de simulations numeriques a des resultats experimentaux obtenus par l'equipe de quantronique du CEASaclay. Ces resultats sont ceux d'une spectroscopie d'un qubit supraconducteur couple a un resonateur non lineaire excite. Dans un regime de faible puissance de spectroscopie le modele reduit predit correctement la position et la largeur de la raie. La position de la raie subit les decalages de Lamb et de Stark, et sa largeur est dominee par un dephasage induit par le processus de mesure. Je montre que, pour les parametres typiques de l'electrodynamique quantique en circuit, un accord quantitatif requiert un modele en reponse non lineaire du champ intra-resonateur, tel que celui developpe. Dans un regime de forte puissance de spectroscopie, des bandes laterales apparaissent et sont causees par les fluctuations quantiques du champ electromagnetique

  17. Basic Design Report of DC-TOF Inelastic Neutron Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    So, Ji Yong; Park, Je Geun; Moon, Myung Kook; Cho, Sang Jin; Choi, Yung Hyun; Lee, Chang Hee

    2006-04-15

    We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.

  18. Highly accurate adaptive TOF determination method for ultrasonic thickness measurement

    Science.gov (United States)

    Zhou, Lianjie; Liu, Haibo; Lian, Meng; Ying, Yangwei; Li, Te; Wang, Yongqing

    2018-04-01

    Determining the time of flight (TOF) is very critical for precise ultrasonic thickness measurement. However, the relatively low signal-to-noise ratio (SNR) of the received signals would induce significant TOF determination errors. In this paper, an adaptive time delay estimation method has been developed to improve the TOF determination’s accuracy. An improved variable step size adaptive algorithm with comprehensive step size control function is proposed. Meanwhile, a cubic spline fitting approach is also employed to alleviate the restriction of finite sampling interval. Simulation experiments under different SNR conditions were conducted for performance analysis. Simulation results manifested the performance advantage of proposed TOF determination method over existing TOF determination methods. When comparing with the conventional fixed step size, and Kwong and Aboulnasr algorithms, the steady state mean square deviation of the proposed algorithm was generally lower, which makes the proposed algorithm more suitable for TOF determination. Further, ultrasonic thickness measurement experiments were performed on aluminum alloy plates with various thicknesses. They indicated that the proposed TOF determination method was more robust even under low SNR conditions, and the ultrasonic thickness measurement accuracy could be significantly improved.

  19. A TDC module used in nTOF of ICF

    International Nuclear Information System (INIS)

    Zhang Yuehua; Li Feng; Jin Ge; Yu Xiaoqi; Jiang Xiao

    2007-01-01

    Neutron time-of-flight (TOF) can provide important information about the fuel-ion burn temperature in various inertial-confinement-fusion (ICF) target designs. The sensitive neutron detector array is used to increase sensitivity while maintaining good time resolution for low-yield targets. It has been a standard technique to diagnose the average density-radius product(pR), which is a very important parameter in ICF experiments. The time resolution of the sensitive neutron detector array which will be used in 'Shen Guang III' system is expected to be 1 ns, and the one of the electronic system connected with the detectors is 100 ps. Based on the next generation of TDCs from ACAM, TDC-GP2, a VME-plug-in multi-chanel TDC module, with a time-resolution of less than 61 ps, has been designed. (authors)

  20. MALDI-TOF MS typing of a nosocomial methicillin-resistant Staphylococcus aureus outbreak in a neonatal intensive care unit.

    Science.gov (United States)

    Steensels, Deborah; Deplano, Ariane; Denis, Olivier; Simon, Anne; Verroken, Alexia

    2017-08-01

    The early detection of a methicillin-resistant Staphylococcus aureus (MRSA) outbreak is decisive to control its spread and rapidly initiate adequate infection control measures. Therefore, prompt determination of epidemiologic relatedness of clinical MRSA isolates is essential. Genetic typing methods have a high discriminatory power but their availability remains restricted. In this study, we aimed to challenge matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) as a typing tool of a nosocomial MRSA outbreak in a neonatal intensive care unit. Over a 2-year period, 15 MRSA isolates were recovered from patients (n = 14) and health care workers (n = 1) at the neonatal intensive care unit. Five reference strains were included for comparison. Identification was performed by MALDI-TOF MS and susceptibility profiles determined by automated broth microdilution. Typing analysis by MALDI-TOF MS included mean spectrum profiles and subsequent dendrogram creation using BioNumerics software. Results were compared with spa typing and pulsed-field gel electrophoresis (PFGE). Our study showed good concordance (93%) between PFGE, spa typing, and MALDI-TOF MS for the outbreak-related MRSA strains. MALDI-TOF MS typing showed excellent typeability and discriminatory power but showed poor reproducibility. This study is one of the first to document the potential usefulness of MALDI-TOF MS with standardized data analysis as a typing tool for investigating a nosocomial MRSA outbreak. A concordance of 93% compared to reference typing techniques was observed. However, because of poor reproducibility, long-term follow-up of prospective isolated strains is not practical for routine use. Further studies are needed to confirm our observations.

  1. APD Response Time Measurements for Future TOF-E Systems

    Science.gov (United States)

    Starkey, M. J.; Ogasawara, K.; Dayeh, M. A.; Desai, M. I.

    2017-12-01

    In space physics, the ability to detect ions is crucial to understanding plasma distributions in the solar wind. This usually typically requires the determination of the particle's mass, charge, and total energy. Current ion detection schemes are implemented in three sequential parts; an electrostatic analyzer for energy per charge (E/Q) measurements, a time-of-flight (TOF) for mass per charge (M/Q) measurements, and a solid-state detector (SSD) for total energy (E) measurements. Recent work has suggested the use of avalanche photodiode detectors (APD) for a simultaneous TOF and total energy (TOF-E) measurement system, which would replace traditional SSDs, simplify design, and reduce costs. Although TOF based ion spectrometry typically requires timing resolution of systems.

  2. The Merit(nTOF-11) High Intensity Liquid Mercury Target Experiment at the CERN PS

    CERN Document Server

    Efthymiopoulos, I; Caretta, O; Carroll, A J; Fabich, A; Graves, V B; Grudiev, A; Haug, F; Kirk, H G; Lettry, Jacques; Loveridge, P; McDonald, K T; Mokhov, N; Palm, M; Park, H; Pernegger, H; Spampinato, P T; Steerenberg, R; Striganov, S; Tsang, T

    2008-01-01

    The MERIT(nTOF-11) experiment is a proof-ofprinciple test of a target system for a high power proton beam to be used as front-end for a neutrino factory or a muon collider. The experiment took data in autumn 2007 with the fast-extracted beam from the CERN Proton Synchrotron (PS) to a maximum intensity of $30 × 10^{12}$ per pulse. The target system, based on a free mercury jet, is capable of intercepting a 4-MW proton beam inside a 15-T magnetic field required to capture the low energy secondary pions as the source for intense muon beams. Partice detectors installed around the target setup measure the secondary particle flux out of the target and can probe cavitation effects in the mercury jet when excited by an intense proton beam.Preliminary results of the data analysis will be presented here.

  3. A new strategy for faster urinary biomarkers identification by Nano-LC-MALDI-TOF/TOF mass spectrometry

    Directory of Open Access Journals (Sweden)

    Le Meur Y

    2008-11-01

    Full Text Available Abstract Background LC-MALDI-TOF/TOF analysis is a potent tool in biomarkers discovery characterized by its high sensitivity and high throughput capacity. However, methods based on MALDI-TOF/TOF for biomarkers discovery still need optimization, in particular to reduce analysis time and to evaluate their reproducibility for peak intensities measurement. The aims of this methodological study were: (i to optimize and critically evaluate each step of urine biomarker discovery method based on Nano-LC coupled off-line to MALDI-TOF/TOF, taking full advantage of the dual decoupling between Nano-LC, MS and MS/MS to reduce the overall analysis time; (ii to evaluate the quantitative performance and reproducibility of nano-LC-MALDI analysis in biomarker discovery; and (iii to evaluate the robustness of biomarkers selection. Results A pool of urine sample spiked at increasing concentrations with a mixture of standard peptides was used as a specimen for biological samples with or without biomarkers. Extraction and nano-LC-MS variabilities were estimated by analyzing in triplicates and hexaplicates, respectively. The stability of chromatographic fractions immobilised with MALDI matrix on MALDI plates was evaluated by successive MS acquisitions after different storage times at different temperatures. Low coefficient of variation (CV%: 10–22% and high correlation (R2 > 0.96 values were obtained for the quantification of the spiked peptides, allowing quantification of these peptides in the low fentomole range, correct group discrimination and selection of "specific" markers using principal component analysis. Excellent peptide integrity and stable signal intensity were found when MALDI plates were stored for periods of up to 2 months at +4°C. This allowed storage of MALDI plates between LC separation and MS acquisition (first decoupling, and between MS and MSMS acquisitions while the selection of inter-group discriminative ions is done (second decoupling

  4. A new strategy for faster urinary biomarkers identification by Nano-LC-MALDI-TOF/TOF mass spectrometry

    Science.gov (United States)

    Benkali, K; Marquet, P; Rérolle, JP; Le Meur, Y; Gastinel, LN

    2008-01-01

    Background LC-MALDI-TOF/TOF analysis is a potent tool in biomarkers discovery characterized by its high sensitivity and high throughput capacity. However, methods based on MALDI-TOF/TOF for biomarkers discovery still need optimization, in particular to reduce analysis time and to evaluate their reproducibility for peak intensities measurement. The aims of this methodological study were: (i) to optimize and critically evaluate each step of urine biomarker discovery method based on Nano-LC coupled off-line to MALDI-TOF/TOF, taking full advantage of the dual decoupling between Nano-LC, MS and MS/MS to reduce the overall analysis time; (ii) to evaluate the quantitative performance and reproducibility of nano-LC-MALDI analysis in biomarker discovery; and (iii) to evaluate the robustness of biomarkers selection. Results A pool of urine sample spiked at increasing concentrations with a mixture of standard peptides was used as a specimen for biological samples with or without biomarkers. Extraction and nano-LC-MS variabilities were estimated by analyzing in triplicates and hexaplicates, respectively. The stability of chromatographic fractions immobilised with MALDI matrix on MALDI plates was evaluated by successive MS acquisitions after different storage times at different temperatures. Low coefficient of variation (CV%: 10–22%) and high correlation (R2 > 0.96) values were obtained for the quantification of the spiked peptides, allowing quantification of these peptides in the low fentomole range, correct group discrimination and selection of "specific" markers using principal component analysis. Excellent peptide integrity and stable signal intensity were found when MALDI plates were stored for periods of up to 2 months at +4°C. This allowed storage of MALDI plates between LC separation and MS acquisition (first decoupling), and between MS and MSMS acquisitions while the selection of inter-group discriminative ions is done (second decoupling). Finally the recording of

  5. Online control package for COSY-TOF experiment

    Energy Technology Data Exchange (ETDEWEB)

    Borodina, Ekaterina [Institute fuer Kernphysik I, Forschungszentrum Juelich GmbH, 52325, Juelich (Germany); Moscow State Institute of Electronics and Mathematics (Russian Federation); Roderburg, Eduard; Ritman, James [Institute fuer Kernphysik I, Forschungszentrum Juelich GmbH, 52325, Juelich (Germany)

    2009-07-01

    The new Straw Tube Tracker and Quirl Microstrip detectors have been installed at the TOF (Time Of Flight) experiment at the COSY accelerator in IKP FZ-Juelich. These new detectors increase the number of channels of the COSY-TOF detector by about a factor of 3. Therefore, a new control package to adjust electronic parameters and for control the proper functionality of all channels is being developed. The online controlling based on visualization of key parameters of detectors plays an important role. The concept and the techniques of the online software package are developed for the COSY-TOF experiment. It consists of conversion software, which transforms a binary data stream from the DAQ to detector oriented event format, methods of IPC (Inter-Process Communications), and GUI (graphical user interface). To achieve data transfer through the network and real time data performance the IPC tools - sockets and shared memory are used. A special GUI, TOF-ONLINE has been developed, based on ROOT. The GUI allows the detectors, plotting spectra, resetting data, etc., to be selected in an intuitive way. Examples of the visualization and the results of the first beam time will be introduced.

  6. TOF-SIMS imaging technique with information entropy

    International Nuclear Information System (INIS)

    Aoyagi, Satoka; Kawashima, Y.; Kudo, Masahiro

    2005-01-01

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is capable of chemical imaging of proteins on insulated samples in principal. However, selection of specific peaks related to a particular protein, which are necessary for chemical imaging, out of numerous candidates had been difficult without an appropriate spectrum analysis technique. Therefore multivariate analysis techniques, such as principal component analysis (PCA), and analysis with mutual information defined by information theory, have been applied to interpret SIMS spectra of protein samples. In this study mutual information was applied to select specific peaks related to proteins in order to obtain chemical images. Proteins on insulated materials were measured with TOF-SIMS and then SIMS spectra were analyzed by means of the analysis method based on the comparison using mutual information. Chemical mapping of each protein was obtained using specific peaks related to each protein selected based on values of mutual information. The results of TOF-SIMS images of proteins on the materials provide some useful information on properties of protein adsorption, optimality of immobilization processes and reaction between proteins. Thus chemical images of proteins by TOF-SIMS contribute to understand interactions between material surfaces and proteins and to develop sophisticated biomaterials

  7. Towards Spectral Library-free MALDI-TOF MS Bacterial Identification.

    Science.gov (United States)

    Cheng, Ding; Qiao, Liang; Horvatovich, Péter

    2018-05-11

    Bacterial identification is of great importance in clinical diagnosis, environmental monitoring and food safety control. Among various strategies, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has drawn significant interests, and has been clinically used. Nevertheless, current bioinformatics solutions use spectral libraries for the identification of bacterial strains. Spectral library generation requires acquisition of MALDI-TOF spectra from monoculture bacterial colonies, which is time-consuming and not possible for many species and strains. We propose a strategy for bacterial typing by MALDI-TOF using protein sequences from public database, i.e. UniProt. Ten genes were identified to encode proteins most often observed by MALD-TOF from bacteria through 500 times repeated a 10-fold double cross-validation procedure, using 403 MALDI-TOF spectra corresponding to 14 genera, 81 species and 403 strains, and the protein sequences of 1276 species in UniProt. The 10 genes were then used to annotate peaks on MALDI-TOF spectra of bacteria for bacterial identification. With the approach, bacteria can be identified at the genus level by searching against a database containing the protein sequences of 42 genera of bacteria from UniProt. Our approach identified 84.1% of the 403 spectra correctly at the genus level. Source code of the algorithm is available at https://github.com/dipcarbon/BacteriaMSLF.

  8. [Evaluation of mass spectrometry: MALDI-TOF MS for fast and reliable yeast identification].

    Science.gov (United States)

    Relloso, María S; Nievas, Jimena; Fares Taie, Santiago; Farquharson, Victoria; Mujica, María T; Romano, Vanesa; Zarate, Mariela S; Smayevsky, Jorgelina

    2015-01-01

    The matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique known as MALDI-TOF MS is a tool used for the identification of clinical pathogens by generating a protein spectrum that is unique for a given species. In this study we assessed the identification of clinical yeast isolates by MALDI-TOF MS in a university hospital from Argentina and compared two procedures for protein extraction: a rapid method and a procedure based on the manufacturer's recommendations. A short protein extraction procedure was applied in 100 isolates and the rate of correct identification at genus and species level was 98.0%. In addition, we analyzed 201 isolates, previously identified by conventional methods, using the methodology recommended by the manufacturer and there was 95.38% coincidence in the identification at species level. MALDI TOF MS showed to be a fast, simple and reliable tool for yeast identification. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Description of a Reactivity Measuring Apparatus; Description d'un Type d'Appareil de Mesure de la Reactivite

    Energy Technology Data Exchange (ETDEWEB)

    Deiss, M.; Uberschlag, J. [Centre d' Etudes Nucleaires de Saclay (France)

    1966-06-15

    apparatuses have different dividers in the output unit, in the one case Potentiometric, and in the other electronic. The first apparatus is suitable in principle for most normal measurements. The second, by reason of its shorter response time, is suited both to measurements of higher reactivity values with the reactor level rising, and also with the reactor level falling, even over limited power ranges. (author) [French] La mesure de la periode ou du temps de doublement fournit en general au technicien du controle des reacteurs une information suffisante sur l'evolution du reacteur. Le physicien attache a la determination de parametres physiques ne peut se satisfaire de la mesure ordinaire de ces grandeurs, dont les concepts font abstraction de la nature du phenomene de la fission nucleaire. Habituellement le physicien doit donc convertir la mesure du temps de doublement, effectuee sur un temps suffisamment long, afin d'en eliminer les termes transitoires perturbateurs, et convertir, par intermediaire des courbes de Nordheim, cette mesure en valeur de reactivite. Cette procedure est longue et contraignante. Il a donc semble utile de concevoir un type d'appareil capable d'evaluer directement et instantanement le coefficient de multiplication excedentaire Greek-Small-Letter-Delta K a partir de l'evolution d'une grandeur physique N supposee proportionnelle au flux neutronique regnant dans le coeur du reacteur. Le coefficient Greek-Small-Letter-Delta K est pratiquement assimilable a la reactivite au voisinage de la criticalite. Un appareil de ce type peut en consequence resoudre la relation inverse a celle definie par le systeme des equations differentielles se rapportant au reacteur, en considerant le cas simplifie du reacteur point dans la theorie a un groupe. L'application des techniques du calcul analogique conduit a utiliser un reseau du type Pagels qui sera dispose, soit comme impedance d'entree, soit comme impedance de contre-reaction d'un amplificateur operationnel. Cette

  10. Groundwater Monitoring Plan for the 1301-N, 1324-N/NA, and 1325-N RCRA Facilities

    International Nuclear Information System (INIS)

    Hartman, Mary J.

    2001-01-01

    The 1301-N and 1325-N Liquid Waste Disposal Facilities, the 1324-N Surface Impoundment, and the 1324-NA Percolation Pond, located in the 100 N Area of the Hanford Site, are regulated under the Resource Conservation and Recovery Act of 1976 (RCRA). The closure plans for these facilities stipulate that groundwater is monitored according to the 100-N Pilot Project: Proposed Consolidated Groundwater Monitoring Program (BHI-00725). This document supplements the consolidated plan by providing information on sampling and analysis protocols, quality assurance, data management, and a conceptual model for the RCRA sites. Monitoring well networks, constituents, and sampling frequency remain the same as in the consolidated plan or the previous groundwater monitoring plan (Hartman 1996)

  11. Angular distributions in the neutron-induced fission of actinides

    CERN Multimedia

    In 2003 the n_TOF Collaboration performed the fission cross section measurement of several actinides ($^{232}$Th, $^{233}$U, $^{234}$U, $^{237}$Np) at the n_TOF facility using an experImental setup made of Parallel Plate Avalanche Counters (PPAC). The method based on the detection of the 2 fragments in coincidence allowed to clearly disentangle the fission reactions among other types of reactions occurring in the spallation domain. We have been therefore able to cover the very broad neutron energy range 1eV-1GeV, taking full benefit of the unique characteristics of the n_TOF facility. Figure 1 shows an example obtained in the case of $^{237}$Np where the n_ TOF measurement showed that the cross section was underestimated by a large factor in the resonance region.

  12. Measurement of neutron total cross-sections for {sup nat}Dy at Pohang Neutron Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S. G.; Kye, Y. U.; Shvetsov, Valery; Cho, M. H. [POSTECH, Pohang (Korea, Republic of); Namkung, W.; Cho, M. H. [Pohang Accelerator Laboratory, Pohang (Korea, Republic of); Kim, G. N. [Kyungpook National Univ., Daegu (Korea, Republic of); Lee, M. W. [Dongnam Inst. of radiological and Medical Science, Busan (Korea, Republic of)

    2013-05-15

    There are few measurements for Dy below 100 eV. Moreover, there exist discrepancies among the measurements. In the present work, the total neutron cross-sections for {sup nat}Dy were measured by using the time-of-flight (TOF) method at the Pohang Neutron Facility (PNF). The PNF consists of an electron linac, a water-cooled Ta target, and an 11-m-long TOF path. The characteristics of PNF are described elsewhere. We also briefly discuss the future plan to verify our experimental result. We have measured the total neutron cross-sections of {sup nat}Dy in the neutron energy region from 0.1 eV to 100 eV with the TOF method at the Po hang Neutron Facility. The present result is in good agreement with the previous data and the evaluated data in ENDF/B-VI. We would like to get resonance parameters by using SAMMY or REFIT codes.

  13. CHANDA and ERINDA: Joint European programs for research on safety of nuclear facilities and waste reduction

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, Roland; Hannaske, Roland; Koegler, Toni [Institut fuer Strahlenphysik, Helmholtz Zentrum DD-Rossendorf, 01328 Dresden (Germany); Institut fuer Kern- und Teilchenphysik, TU Dresden, 01069 Dresden (Germany); Grosse, Eckart [Institut fuer Kern- und Teilchenphysik, TU Dresden, 01069 Dresden (Germany); Junghans, Arnd R. [Institut fuer Strahlenphysik, Helmholtz Zentrum DD-Rossendorf, 01328 Dresden (Germany)

    2014-07-01

    In spite of the planned termination of the German nuclear power program neutron beam facilities in Germany can contribute considerably to research studies on the reduction of hazards due to nuclear waste. Transnational research programs support EU groups who want to carry out projects at the new tof set-up nELBE at HZDR, the calibrated n-flux at PTB and the FRANZ accelerator under construction at Frankfurt. Vice versa various facilities in the EU offer beams for transmutation and safety related studies with neutrons to German scientists under support by ERINDA (2011-2013) and CHANDA (2014-2017; solving challenges in nuclear data for the safety of European nuclear facilities). For work in that field scientific visits are also fostered to improve the exchange of experience between the partners (13 and in future about 35 from 18 countries). Plans for new projects as well as results obtained so far are discussed, and special emphasis is given to the present research performed at nELBE on neutron scattering and absorption.

  14. Characterisation of the aerobic bacterial flora of boid snakes: application of MALDI-TOF mass spectrometry.

    Science.gov (United States)

    Plenz, Bastian; Schmidt, Volker; Grosse-Herrenthey, Anke; Krüger, Monika; Pees, Michael

    2015-03-14

    The aim of this study was to identify aerobic bacterial isolates from the respiratory tract of boids with matrix-assisted laser desorption ionisation-time-of-flight mass spectrometry (MALDI-TOF MS). From 47 boid snakes, swabs from the oral cavity, tracheal wash samples and, in cases in which postmortem examination was performed, pulmonary tissue samples were taken. Each snake was classified as having inflammation of the respiratory tract and/or oral cavity, or without evidence of inflammation based on combination of clinical, cytological and histopathological findings. Samples collected from the respiratory tract and oral cavity were inoculated onto routine media and bacteria were cultured aerobically. All morphologically distinct individual colonies obtained were analysed using MALDI-TOF MS. Unidentified isolates detected in more than three snakes were selected for further 16S rDNA PCR and sequencing. Among all examined isolates (n=243), 49 per cent (n=119) could be sufficiently speciated using MALDI-TOF MS. Molecular biology revealed several bacterial species that have not been previously described in reptiles. With an average of 6.3 different isolates from the respiratory tract and/or oral cavity, boids with inflammatory disease harboured significantly more bacterial species than boids without inflammatory disease (average 2.8 isolates). British Veterinary Association.

  15. 1325-N Liquid Waste Disposal Facility Supplemental Information to the Hanford Facility Contingency Plan (DOE/RL-93-75)

    International Nuclear Information System (INIS)

    Edens, V.G.

    1998-03-01

    The 1325-N Liquid Waste Disposal Facility located at the 100-N Area of the Hanford Site started receiving part of the N Reactor liquid radioactive effluent flow in 1983. In September 1985, the 1325-N Facility became the primary liquid waste disposal system for the N Reactor. The facility is located approximately 60 feet above and 2000 feet east of the shore of the Columbia River. Waste stream discharges were ceased in April 1991.Specific information on types of waste discharged to 1325-N are contained within the Part A, Form 3, Permit application of this unit

  16. The identification of anaerobic bacteria using MALDI-TOF MS

    NARCIS (Netherlands)

    Veloo, A. C. M.; Welling, G. W.; Degener, J. E.

    Matrix Assisted Laser Desorption and Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) has gained more and more popularity for the identification of bacteria. Several studies show that bacterial diagnosticis is being revolutionized by the application of MALDI-TOF MS. For anaerobic bacteria,

  17. Development of inelastic neutron spectrometer (DC-TOF) and utilization

    International Nuclear Information System (INIS)

    Park, Je Geun; So, J. Y.; Moon, M. K.; Choi, Y. H.; Cho, S. J.; Lee, C. H.; Nam, U. W.; Kim, H. Y.; Kim, H. J.

    2010-08-01

    DC-TOF is an inelastic neutron spectrometer with potentially very wide applications to areas such as physics, chemistry, biology, and material engineering. And it is the most technically challenging and advanced instrument by using high speed choppers rotating up to 20,000 RPM and wide detector of steradian producing data in the order of a few hundred Mbyte. Through this project, we have successfully developed DC-TOF at KAERI with the development of the following key technologies : - Detector Electronics - Data acquisition software - Data reduction software. We believe that DC-TOF will become a workhorse instrument for the wide community of sciences in Korea

  18. Measurements of double-differential neutron emission cross sections of Nb and Bi for 11.5 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Ibaraki, Masanobu; Matsuyama, Shigeo; Soda, Daisuke; Baba, Mamoru; Hirakawa, Naohiro [Tohoku Univ., Sendai (Japan). Faculty of Engineering

    1997-03-01

    Double-differential neutron emission cross sections (DDXs) of Nb and Bi have been measured for 11.5MeV neutrons using the {sup 15N}(d,n){sup 16}O quasi-monoenergetic neutron source at Tohoku University 4.5MV Dynamitron facility. For En`>6MeV, DDXs were measured by the conventional TOF method (single-TOF:S-TOF). For En`<6MeV, where the S-TOF spectra were distorted by the background neutrons, we adopted a double-TOF method (D-TOF). By applying D-TOF method, we obtained DDXs down to 1MeV. (author)

  19. MALDI-TOF-mass spectrometry applications in clinical microbiology.

    Science.gov (United States)

    Seng, Piseth; Rolain, Jean-Marc; Fournier, Pierre Edouard; La Scola, Bernard; Drancourt, Michel; Raoult, Didier

    2010-11-01

    MALDI-TOF-mass spectrometry (MS) has been successfully adapted for the routine identification of microorganisms in clinical microbiology laboratories in the past 10 years. This revolutionary technique allows for easier and faster diagnosis of human pathogens than conventional phenotypic and molecular identification methods, with unquestionable reliability and cost-effectiveness. This article will review the application of MALDI-TOF-MS tools in routine clinical diagnosis, including the identification of bacteria at the species, subspecies, strain and lineage levels, and the identification of bacterial toxins and antibiotic-resistance type. We will also discuss the application of MALDI-TOF-MS tools in the identification of Archaea, eukaryotes and viruses. Pathogenic identification from colony-cultured, blood-cultured, urine and environmental samples is also reviewed.

  20. Développement de la pupillométrie pour la mesure objective des émotions dans le contexte de la consommation alimentaire

    OpenAIRE

    Lemercier, Anaïs

    2014-01-01

    Les perceptions sensorielles et hédoniques résultent de processus complexes d’intégration, qui ne sont pas seulement rationnels, mais aussi fondés sur des sentiments, des émotions et des souvenirs. Afin d'appréhender au mieux le comportement du consommateur, il est devenu indispensable de mesurer les émotions afin de comprendre leur rôle fondamental dans la prise de décision. En science du consommateur, les émotions sont principalement mesurées par questionnaire. Malheureusement, cette mesure...

  1. Short communication: Evaluation of MALDI-TOF mass spectrometry and a custom reference spectra expanded database for the identification of bovine-associated coagulase-negative staphylococci.

    Science.gov (United States)

    Cameron, M; Perry, J; Middleton, J R; Chaffer, M; Lewis, J; Keefe, G P

    2018-01-01

    This study evaluated MALDI-TOF mass spectrometry and a custom reference spectra expanded database for the identification of bovine-associated coagulase-negative staphylococci (CNS). A total of 861 CNS isolates were used in the study, covering 21 different CNS species. The majority of the isolates were previously identified by rpoB gene sequencing (n = 804) and the remainder were identified by sequencing of hsp60 (n = 56) and tuf (n = 1). The genotypic identification was considered the gold standard identification. Using a direct transfer protocol and the existing commercial database, MALDI-TOF mass spectrometry showed a typeability of 96.5% (831/861) and an accuracy of 99.2% (824/831). Using a custom reference spectra expanded database, which included an additional 13 in-house created reference spectra, isolates were identified by MALDI-TOF mass spectrometry with 99.2% (854/861) typeability and 99.4% (849/854) accuracy. Overall, MALDI-TOF mass spectrometry using the direct transfer method was shown to be a highly reliable tool for the identification of bovine-associated CNS. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  2. Neutron diffraction utilizing the T-O-F method

    Energy Technology Data Exchange (ETDEWEB)

    Niimura, N [Tohoku Univ., Sendai (Japan). Lab. of Nuclear Science

    1974-12-01

    Characteristic features of the TOF (time of flight) neutron diffraction are summarized. In this method, i) all the reciprocal points on the rod passing through the origin in the reciprocal space can be scanned by each burst of white neutrons, ii) it is easy to measure high index reflections at the large scattering angle, iii) each reflection is not affected by the higher-order harmonics, and iv) it is easy to measure the physical properties depending on the neutron wavelength. The pulse neutron generator as well as the data acquisition system in the Laboratory of Nuclear Science of Tohoku University is described. The TOF method seems to be very powerful if it is applied to accurate structure analysis. The data correction methods are discussed. The TOF method is prospective to the study of transient phenomena. In this method one can apply to the crystalline sample an external field pulsed with the same frequency as the neutrons. By using this method, the transient state of the polarization reversal of the ferroelectric NaNO/sub 2/ has been observed. The magnetically pulsed neutron TOF spectrometer is briefly introduced after a review of the chopper history.

  3. A CVD diamond detector for (n,α) cross-section measurements

    International Nuclear Information System (INIS)

    Weiss, C.

    2014-01-01

    A novel detector based on the chemical vapor deposition (CVD) diamond technology has been developed in the framework of this PhD, for the experimental determination of (n,α) cross-sections at the neutron time-of-flight facility n⎽TOF at CERN. The 59 Ni(n,α) 56 Fe cross-section, which is relevant for astrophysical questions as well as for risk-assessment studies in nuclear technology, has been measured in order to validate the applicability of the detector for such experiments. The thesis is divided in four parts. In the introductory part the motivation for measuring (n,α) cross-sections, the experimental challenges for such measurements and the reasons for choosing the CVD diamond technology for the detector are given. This is followed by the presentation of the n⎽TOF facility, an introduction to neutron-induced nuclear reactions and a brief summary of the interaction of particles with matter. The CVD diamond technology and the relevant matters related to electronics are given as well in this first part of the thesis. The second part is dedicated to the design and production of the Diamond Mosaic-Detector (DM-D) and its characterization. The 59 Ni(n,α) 56 Fe cross-section measurement at n⎽TOF and the data analysis are discussed in detail in the third part of the thesis, before the summary of the thesis and an outlook to possible future developments and applications conclude the thesis in the forth part. In this work, the Diamond Mosaic-Detector, which consist of eight single-crystal (sCVD) diamond sensors and one 'Diamond on Iridium' (DOI) sensor has proven to be well suited for (n,α) cross-section measurements for 1 MeV < E α < 22 MeV. The upper limit is given by the thickness of the sensors, d = 150 μm, while the lower limit is dictated by background induced by neutron capture reactions in in-beam materials. The cross-section measurement was focussed on the resonance integral of 59 Ni(n,α) 56 Fe at E n = 203 eV, with the aim of clarifying

  4. Mesures de contraintes in-situ. Méthode de relaxation des carottes Measuring in-Situ Stresses. Relaxation Method with Core Samples

    Directory of Open Access Journals (Sweden)

    Perreau P.

    2006-11-01

    Full Text Available Dans cet article, on se propose de présenter les premiers résultats de l'étude de la méthode d'évaluation des contraintes par mesure de déformations différées d'une carotte après son extraction. Le travail correspondant a été réalisé dans le cadre du projet ARTEP Fracturation hydraulique . Les principes de cette méthode et les quelques éléments d'interprétation récemment publiés dans la littérature sont exposés dans un premier temps. Les résultats de deux campagnes de mesures sur deux puits de la SNEA-P (Soudron, novembre 1985 et Lanot, juillet 1986 sont ensuite présentés. Ces essais ont mis en évidence que les déformations différées d'une carotte dues au relachement des contraintes sont effectivement mesurables. Cependant, une interprétation quantitative de ces mesures nécessite une amélioration des conditions expérimentales (stabilisation thermique, stabilisation de l'état de saturation. This article describes the first results of research on a method of evaluating stresses by measuring the differred deformations of a core sample after it has been extracted. The corresponding research was done within the framework of an ARTEP project on Hydraulic Fracturing . The principles of this method and several interpretation aspects published recently in the literature are described in the first part. Then the results of two measurement campaigns using two SNEA-P wells (Soudron in November 1985 and Lanot in July 1986 are described. These tests revealed that the differed deformations of a core sample due to the relaxing of stresses can effectively be measured. However, a quantitative interpretation of these measurements requires an improvement to be made in the experimental conditions (thermal stabilization, stabilization of the state of saturation.

  5. Complementary b/y fragment ion pairs from post-source decay of metastable YahO for calibration of MALDI-TOF-TOF-MS/MS

    Science.gov (United States)

    Complementary b/y fragment ion pairs from post-source decay (PSD) of metastable YahO protein ion were evaluated for use in the calibration of MALDI-TOF-TOF for tandem mass spectrometry (MS/MS). The yahO gene from pathogenic Escherichia coli O157:H7 strain EDL933 was cloned into a pBAD18 plasmid vect...

  6. Quantified, Interactive Simulation of AMCW ToF Camera Including Multipath Effects.

    Science.gov (United States)

    Bulczak, David; Lambers, Martin; Kolb, Andreas

    2017-12-22

    In the last decade, Time-of-Flight (ToF) range cameras have gained increasing popularity in robotics, automotive industry, and home entertainment. Despite technological developments, ToF cameras still suffer from error sources such as multipath interference or motion artifacts. Thus, simulation of ToF cameras, including these artifacts, is important to improve camera and algorithm development. This paper presents a physically-based, interactive simulation technique for amplitude modulated continuous wave (AMCW) ToF cameras, which, among other error sources, includes single bounce indirect multipath interference based on an enhanced image-space approach. The simulation accounts for physical units down to the charge level accumulated in sensor pixels. Furthermore, we present the first quantified comparison for ToF camera simulators. We present bidirectional reference distribution function (BRDF) measurements for selected, purchasable materials in the near-infrared (NIR) range, craft real and synthetic scenes out of these materials and quantitatively compare the range sensor data.

  7. Quantified, Interactive Simulation of AMCW ToF Camera Including Multipath Effects

    Directory of Open Access Journals (Sweden)

    David Bulczak

    2017-12-01

    Full Text Available In the last decade, Time-of-Flight (ToF range cameras have gained increasing popularity in robotics, automotive industry, and home entertainment. Despite technological developments, ToF cameras still suffer from error sources such as multipath interference or motion artifacts. Thus, simulation of ToF cameras, including these artifacts, is important to improve camera and algorithm development. This paper presents a physically-based, interactive simulation technique for amplitude modulated continuous wave (AMCW ToF cameras, which, among other error sources, includes single bounce indirect multipath interference based on an enhanced image-space approach. The simulation accounts for physical units down to the charge level accumulated in sensor pixels. Furthermore, we present the first quantified comparison for ToF camera simulators. We present bidirectional reference distribution function (BRDF measurements for selected, purchasable materials in the near-infrared (NIR range, craft real and synthetic scenes out of these materials and quantitatively compare the range sensor data.

  8. Silicon P.I.N. Junctions used for studies of radiation damage; Etude de l'irradiation aux neutrons rapides du silicium au moyen de jonctions P.I.N

    Energy Technology Data Exchange (ETDEWEB)

    Lanore, J [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-06-01

    Irradiation of silicon P.I.N. junction has been studied primarily for the purpose of developing a radiation damage dosimeter, but also for the purpose of investigating silicon itself. It is known that the rate of recombination of electrons and holes is a linear function of defects introduced by neutron irradiation. Two methods have been used to measure that rate of recombination: forward characteristic measurements, recovery time measurements. In order to explain how these two parameters depend on recombination rate we have given a theory of the P.I.N. junction. We have also given an idea of the carrier lifetime dependence versus temperature. Annealing effects in the range of 70 to 700 K have also been studied, we found five annealing stages with corresponding activation energies. As an application for these studies, we developed a radiation damage dosimeter with which we made several experiments in facilities such as Naiade or Marias. (author) [French] L'irradiation de structures P.I.N. etait faite dans le but d'etudier principalement la mise au point d'un dosimetre a ''radiation damage'' et aussi pour etudier plus profondement le silicium lui-meme. On sait que le taux de recombinaison electrons-trous est une fonction lineaire du taux de defauts introduits par irradiation aux neutrons. Deux methodes ont ete utilisees pour atteindre ce taux de recombinaison: mesures de la caracteristique directe, mesures du temps de retournement. Pour expliquer de quelle facon ces parametres dependent du taux de recombinaison. Nous avons donne une theorie de la jonction P.I.N. Nous avons aussi donne l'allure des variations du temps de vie des porteurs en fonction de la temperature. Nous avons d'autre part effectue des recuits entre 70 et 700 K, domaine dans lequel nous avons trouve cinq etapes de ''guerison'' avec les energies d'activation correspondantes. En application de ces etudes nous avons mis ou point un dosimetre a ''radiation damage'' avec lequel nous avons effectue des

  9. ESARDA approach to facility oriented safeguards problems

    International Nuclear Information System (INIS)

    Stewart, R.

    1979-01-01

    The paper outlines the brief history of a Working Group composed of nuclear fuel plant operators, safeguards research workers and safeguards inspectors who are examining facility orientated problems of nuclear materials control and verification activities. The working program is reviewed together with some examples of various problems and the way the group is collaborating to develop solutions by pooling resources and effort. Work in European low enriched uranium fabrication plants from UF 6 to finished fuel is discussed in connection with mesurement practices, real time accounting, error propagation and analysis, verification and surveillance

  10. Le temps mesurable, réversible, insaisissable ?

    CERN Document Server

    Fink, Martin; Leduc , Michèle

    2016-01-01

    Depuis l'Antiquité, la nature du temps a fasciné nombre de grands penseurs. Cet ouvrage expose ce que la physique est capable de dire aujourd'hui sur le sujet. La mesure du temps, ou plus exactement celle d'une durée, se fait grâce à des horloges atomiques dont l'exactitude peut atteindre une seconde sur plusieurs milliards d'années. Nous décrivons la façon dont s'effectue le transfert du temps qui permet la synchronisation d'horloges en différents points de la Terre ou de l'espace au milliardième de seconde près, ou même mieux. Les relativités, restreinte et générale, ont bouleversé notre conception du temps et ont un impact considérable sur certains problèmes de la vie quotidienne comme l'utilisation du GPS. On abandonne l'idée d'un temps absolu, le temps devient multiple et insaisissable, et peut-être même une illusion. Enfin la flèche du temps, ou l'irréversibilité, implique que les phénomènes physiques se déroulent toujours dans un sens déterminé, en relation avec la croissan...

  11. Integral measurement of the {sup 12}C(n, p){sup 12}B reaction up to 10 GeV

    Energy Technology Data Exchange (ETDEWEB)

    Zugec, P.; Bosnar, D. [University of Zagreb, Department of Physics, Faculty of Science, Zagreb (Croatia); Colonna, N.; Barbagallo, M.; Mastromarco, M.; Tagliente, G.; Variale, V. [Istituto Nazionale di Fisica Nucleare, Bari (Italy); Ventura, A. [Istituto Nazionale di Fisica Nucleare, Bologna (Italy); Mengoni, A. [ENEA, Bologna (Italy); Altstadt, S.; Langer, C.; Lederer, C.; Reifarth, R.; Schmidt, S.; Weigand, M. [Johann-Wolfgang-Goethe Universitaet, Frankfurt (Germany); Andrzejewski, J.; Marganiec, J.; Perkowski, J. [Uniwersytet Lodzki, Lodz (Poland); Audouin, L.; Leong, L.S.; Tassan-Got, L. [Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay (France); Becares, V.; Cano-Ott, D.; Garcia, A.R.; Gonzalez-Romero, E.; Martinez, T.; Mendoza, E. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain); Becvar, F.; Krticka, M.; Kroll, J.; Valenta, S. [Charles University, Prague (Czech Republic); Belloni, F.; Mondalaers, W.; Plompen, A.; Schillebeeckx, P. [European Commission JRC, Institute for Reference Materials and Measurements, Geel (Belgium); Berthoumieux, E.; Fraval, K.; Gunsing, F. [CEA/Saclay - IRFU, Gif-sur-Yvette (France); Billowes, J.; Ware, T.; Wright, T. [University of Manchester, Manchester (United Kingdom); Boccone, V.; Brugger, M.; Calviani, M.; Cerutti, F.; Chiaveri, E.; Chin, M.; Ferrari, A.; Guerrero, C.; Losito, R.; Roman, F.; Rubbia, C.; Tsinganis, A.; Versaci, R.; Vlachoudis, V.; Weiss, C. [CERN, Geneva (Switzerland); Calvino, F.; Cortes, G.; Gomez-Hornillos, M.B.; Riego, A. [Universitat Politecnica de Catalunya, Barcelona (Spain); Carrapico, C.; Goncalves, I.F.; Sarmento, R.; Vaz, P. [Universidade de Lisboa, C2TN-Instituto Superior Tecnico, Lisboa (Portugal); Cortes-Giraldo, M.A.; Praena, J.; Quesada, J. [Universidad de Sevilla, Sevilla (Spain); Cosentino, L.; Finocchiaro, P. [INFN - Laboratori Nazionali del Sud, Catania (Italy); Diakaki, M.; Karadimos, D.; Kokkoris, M.; Vlastou, R. [National Technical University of Athens (NTUA), Athens (Greece); Domingo-Pardo, C.; Giubrone, G.; Tain, J.L. [CSIC-Universidad de Valencia, Instituto de Fisica Corpuscular, Valencia (Spain); Dressler, R.; Heinitz, S.; Kivel, N.; Schumann, D. [Paul Scherrer Institut, Villigen (Switzerland); Duran, I.; Tarrio, D. [Universidade de Santiago de Compostela, Santiago de Compostela (Spain); Eleftheriadis, C.; Manousos, A. [Aristotle University of Thessaloniki, Thessaloniki (Greece); Ganesan, S.; Gurusamy, P.; Saxena, A. [Bhabha Atomic Research Centre (BARC), Mumbai (India); Griesmayer, E.; Jericha, E.; Leeb, H. [Atominstitut der Oesterreichischen Universitaeten, Technische Universitaet Wien, Wien (Austria); Jenkins, D.G.; Vermeulen, M.J. [University of York, York, Heslington (United Kingdom); Kaeppeler, F. [Karlsruhe Institute of Technology (KIT), Institut fuer Kernphysik, Karlsruhe (Germany); Lo Meo, S. [Istituto Nazionale di Fisica Nucleare, Bologna (Italy); ENEA, Bologna (Italy); Massimi, C.; Mingrone, F.; Vannini, G. [Dipartimento di Fisica, Universita di Bologna (IT); INFN, Bologna (IT); Mastinu, P. [Laboratori Nazionali di Legnaro, Istituto Nazionale di Fisica Nucleare, Legnaro (IT); Milazzo, P.M. [Istituto Nazionale di Fisica Nucleare, Trieste (IT); Mirea, M. [Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Magurele (RO); Musumarra, A. [Universita di Catania, Dipartimento di Fisica e Astronomia DFA, Catania (IT); INFN-Laboratori Nazionali del Sud, Catania (IT); Paradela, C. [European Commission JRC, Institute for Reference Materials and Measurements, Geel (BE); Universidade de Santiago de Compostela, Santiago de Compostela (ES); Pavlik, A. [Faculty of Physics, University of Vienna, Wien (AT); Rauscher, T. [University of Hertfordshire, Centre for Astrophysics Research, School of Physics, Astronomy and Mathematics, Hatfield (GB); University of Basel, Department of Physics, Basel (CH); Wallner, A. [Faculty of Physics, University of Vienna, Wien (AT); Australian National University, Research School of Physics and Engineering, Canberra (AU)

    2016-04-15

    The integral measurement of the {sup 12}C(n, p){sup 12}B reaction was performed at the neutron time-of-flight facility nTOF at CERN. The total number of {sup 12}B nuclei produced per neutron pulse of the nTOF beam was determined using the activation technique in combination with a time-of-flight technique. The cross section is integrated over the nTOF neutron energy spectrum from reaction threshold at 13.6 MeV to 10 GeV. Having been measured up to 1GeV on basis of the {sup 235}U(n, f) reaction, the neutron energy spectrum above 200 MeV has been re-evaluated due to the recent extension of the cross section reference for this particular reaction, which is otherwise considered a standard up to 200 MeV. The results from the dedicated GEANT4 simulations have been used to evaluate the neutron flux from 1 GeV up to 10 GeV. The experimental results related to the {sup 12}C(n, p){sup 12}B reaction are compared with the evaluated cross sections from major libraries and with the predictions of different GEANT4 models, which mostly underestimate the {sup 12}B production. On the contrary, a good reproduction of the integral cross section derived from measurements is obtained with TALYS-1.6 calculations, with optimized parameters. (orig.)

  12. Development of DC-TOF control software framework

    International Nuclear Information System (INIS)

    Kim, Hong Joo; Kim, Hyun Ok

    2010-06-01

    Disk-Chopper Time-of-Flight spectrometer (DC-TOF) is a new cold neutron instrument under construction at the Korea Atomic Energy Research Institute (KAERI). It will be equipped with a total of 352 2m PSDs(Position Sensitive Detectors), which are grouped into 11 panels. We developed the main DAQ/Control software works well between multi-DSPs of electronics and user. It is convenient to operate DC-TOF system and monitor it's data quality using GUI(Graphical User Interface). Also it satisfies design throughout with test result of 100K events/s

  13. Transmutation in ADS and needs for nuclear data, with an introduction to the n-TOF at CERN

    CERN Document Server

    González, E; Fernández, R; García, J; Villamarín, D

    1999-01-01

    Transmutation can help in the nuclear waste problem by reducing seriously the life and amount of the most dangerous isotopes (radiotoxicity, heat, packing volume and neutron multiplication reductions). ADS are one of the best technologies for nuclear waste transmutation at large scale. Although enough information is available to prepare conceptual designs and make assessments on their performance, a large R&D campaign is required to obtain the precision data required to optimize the detailed engineering design and refine our expectations calculations on waste reduction by the different transmutation strategies being proposed. In particular a large R&D effort is required in nuclear physics, where fundamental differential measurements and integral verification experiments are required. In this sense, the PS213 n-TOF at CERN PS (at Switzerland) will become one of the largest installations to perform the fundamental differential measurements and a wide international collaboration has been setup to perform...

  14. Etude du mecanisme de predissociation de l'ion moleculaire de protoxyde d'azote par la mesure de l'energie cinetique des fragments de l'oxyde nitrique et de l'oxygene

    Science.gov (United States)

    Delisle, Claude

    La reaction N2 + O+ ↔ NO + + N, laquelle joue un role important dans la physique de la haute atmosphere, a ete le sujet de plusieurs etudes. Bien que cette reaction ait ete l'objet d'une quantite importante de travaux, ces derniers ne permettent toutefois pas de comprendre entierement le mecanisme d'un point de vue quantique, particulierement les niveaux d'energie excites des fragments qui permettent cette reaction. Puisque cette reaction n'est pas tres facile a reproduire en laboratoire, nous avons utilise la spectroscopie laser sur faisceaux d'ions rapides afin d'explorer les limites de dissociation de l'ion moleculaire intermediaire de cette reaction, a savoir l'ion N2O+. Le faisceau d'ions N2O+ rapides, apres excitation de l'ion moleculaire vers un niveau predissocie de l'etat A2Sigma+, se dissocie pour produire les fragments ioniques O+ et NO+. Par la mesure de la variation du nombre de fragments ioniques en fonction de l'energie cinetique des ions N2O+, nous avons enregistre les spectres de predissociation de l'ion N2O+. Lorsque c'etait possible, nous avons procede a l'analyse de ces spectres de dissociation afin d'en tirer les constantes moleculaires. Pour certaines des transitions rotationnelles intenses, nous avons mesure l'energie cinetique acquise par les fragments lors de la predissociation de l'ion N 2O+. Afin d'analyser les distributions en energie cinetique, nous avons developpe une simulation de l'experience en considerant, entre autres choses, la position des niveaux de vibration et de rotation des fragments diatomiques de chacune des limites de dissociation de N2O+. Les resultats de l'analyse sont exprimes en termes de population des niveaux de vibration des fragments diatomiques pour une distribution donnee de la population des niveaux de rotation des fragments. Les resultats ainsi obtenus, montrent que les fragments diatomiques sont produits dans des niveaux de vibration fortement excites. De tels niveaux d'excitation ne correspondent pas aux

  15. CE-TOF/MS: fundamental concepts, instrumental considerations and applications.

    Science.gov (United States)

    Staub, Aline; Schappler, Julie; Rudaz, Serge; Veuthey, Jean-Luc

    2009-05-01

    This review discusses the fundamental principles of TOF analyzers and covers the great progress that has been made in this area in recent years (i.e. orthogonal acceleration, reflectron). This paper also gives an overview of applications performed by CE coupled to TOF/MS detection. The main domains of interest include the analysis of biomolecules and natural compounds.

  16. Automatic magnetic susceptibility measurements between 4 K and 1200 K; Mesure automatique des susceptibilites magnetiques de 4 K a 1200 K

    Energy Technology Data Exchange (ETDEWEB)

    Raphael, G [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    We give a detailed description of a Faraday magnetic susceptibility balance which operates from 4 K to 1200 K. Some preliminary results on platinum and tantalum illustrate the precision and the sensitivity of the measurements. The apparatus has been designed for measurements on the plutonium compounds which present severe health hazards. (author) [French] Nous decrivons en detail un appareil permettant la mesure des susceptibilites magnetiques de 4 K a 1200 K par la methode de FARADAY. Quelques resultats preliminaires sur le platine et le titane montrent la precision et la sensibilite des mesures, L'appareil a ete adapte aux mesures sur les composes particulierement dangereux du plutonium. (auteur)

  17. Neutron measurements in the core and blankets of the reactor Rapsodie; Mesures neutroniques dans le coeur et les couvertures de Rapsodie

    Energy Technology Data Exchange (ETDEWEB)

    Gourdon, J; Edeline, J C [Commissariat a l' Energie Atomique, 13 - Cadarache (France). Centre d' Etudes Nucleaires

    1968-07-01

    Beside a brief general discussion, the report contains all the core and blanket neutronic measurements. It covers successively the methods, the measurements themselves and the results. The later concern: spectral indexes, axial and radial fission rates, activation foil measurements and neutronic power determination. (authors) [French] Apres une breve description generale de RAPSODIE, le rapport presente l'ensemble des mesures neutroniques faites dans le coeur et les couvertures. Il traite dans l'ordre des methodes, des mesures et enfin des resultats qui concernent: les indices de spectres, les taux de fission axiaux et radiaux, les mesures par detecteurs par activation, la determination de la puissance, neutronique. (auteurs)

  18. TOF spectrometer with improved sensitivity for ERDA of light isotopes

    International Nuclear Information System (INIS)

    Siketic, Z.; Bogdanovic Radovic, I.; Jaksic, M.

    2009-01-01

    Time-of-Flight Elastic Recoil Detection Analysis (TOF ERDA) is a well established and powerful ion beam analytical technique. It is used for simultaneous and quantitative analysis of elemental depth distributions of light and medium mass elements in both light and heavy matrices. Contrary to silicon particle detectors, the efficiency of the carbon-foil MCP time detectors in TOF system depends on energy and electronic stopping power of analyzing recoil atoms in the C foil and it is often less than 100% for light elements (H, He, Li). This is particularly critical for hydrogen isotopes where detection efficiency can be drastically reduced (∼ 10%). Therefore, TOF ERDA spectrometers were so far not the best choice for depth profiling and quantification of light elements. To improve the detection efficiency of TOF ERDA, the electron emission of C foils (∼ 0.3 μg/cm 2 ) has been enhanced by evaporating a thin LiF layer on the foil. That procedure improved significantly detection efficiency of hydrogen and other light elements, making TOF ERDA spectrometer more suitable for multielemental analysis applications. The capabilities of upgraded spectrometer were demonstrated on samples with well known as well as unknown concentration and depth distribution of H and D.(author)

  19. [Applications of MALDI-TOF technology in clinical microbiology].

    Science.gov (United States)

    Suarez, S; Nassif, X; Ferroni, A

    2015-02-01

    Until now, the identification of micro-organisms has been based on the cultural and biochemical characteristics of bacterial and fungal species. Recently, Mass Spectrometry type Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF MS) was developed in clinical microbiology laboratories. This new technology allows identification of micro-organisms directly from colonies of bacteria and fungi within few minutes. In addition, it can be used to identify germs directly from positive blood culture bottles or directly from urine samples. Other ways are being explored to expand the use of MALDI-TOF in clinical microbiology laboratories. Indeed, some studies propose to detect bacterial antibiotic resistance while others compare strains within species for faster strain typing. The main objective of this review is to update data from the recent literature for different applications of MALDI-TOF technique in microbiological diagnostic routine. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  20. False positives in MALDI-TOF detection of ERβ in mitochondria

    International Nuclear Information System (INIS)

    Schwend, Thomas; Gustafsson, Jan-Ake

    2006-01-01

    Recently, Yang et al. reported that estrogen receptor beta (ERβ) is a mitochondrial protein rather than a nuclear receptor. Because this claim would lead to a significant change in our understanding of estrogen signaling, we have attempted to reproduce the MALDI-TOF data of Yang et al. We separated proteins extracted from mouse liver mitochondria by SDS-PAGE and analysed a gel band covering the molecular weight range of 50-65 kDa by MALDI-TOF/TOF. Analysis of the data with the MASCOT database algorithm provided no evidence for the presence of ERβ in the mitochondria. If we search (as the authors did) with only the peptide masses which match to tryptic fragments of ERβ, ERβ is identified with a significant score of 69. However, fragmentation of these peptides shows that they are not from ERβ. Our conclusion is that ERβ cannot be identified by MALDI-TOF from a mixture of mitochondrial proteins resolved on SDS-PAGE

  1. Measurements of fission cross-sections and of neutron production rates; Mesures de sections efficaces de fission et du nombre de neutrons prompts emis par fission

    Energy Technology Data Exchange (ETDEWEB)

    Billaud, P; Clair, C; Gaudin, M; Genin, R; Joly, R; Leroy, J L; Michaudon, A; Ouvry, J; Signarbieux, C; Vendryes, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    a) Measurements of neutron induced fission cross-sections in the low energy region. The variation of the fission cross sections of several fissile isotopes has been measured and analysed, for neutron energies below 0,025 eV. The monochromator was a crystal spectrometer used in conjunction with a mechanical velocity selector removing higher order Bragg reflections. The fissile material was laid down on the plates of a fission chamber by painting technic. An ionization chamber, having its plates coated with thin {sup 10}B layers, was used as the neutron flux monitor. b) Measurement of the fission cross section of {sup 235}U. We intend to measure the variation of the neutron induced fission cross section of {sup 235}U over the neutron energy range from 1 keV by the time of flight method. The neutron source is the uranium target of a pulsed 28 MeV electron linear accelerator. The detector is a large fission chamber, with parallel plates, containing about 10 g of {sup 235}U (20 deposits of 25 cm diameter). The relative fission data were corrected for the neutron spectrum measured with a set of BF{sub 3} proportional counters. c) Mean number {nu} of neutrons emitted in neutron induced fission. We measured the value of {nu} for several fissile isotopes in the case of fission induced by 14 MeV neutrons. The 14 MeV neutrons were produced by D (t, n) {alpha} reaction by means of a 300 kV Cockcroft Walton generator. (author)Fren. [French] a) Mesures de sectionficaces de fission a basse energie. Nous avons mesure et analyse la variation de la section efficace de fission de divers isotopes fissiles pour des neutrons d'energie inferieure a 0,025 eV. Le monochromateur est constitue par un spectrometre a cristal auquel est associe un selecteur mecanique destine a eliminer les diffractions de Bragg d'ordre superieur au premier. Le materiau fissile est contenu dans une chambre a fission sous forme de depots realises par peinture; une chambre d'ionisation a depots minces de B{sub 10

  2. Magnetic Resonance Angiography of the pulmonary veins: TOF 3D versus 2D

    International Nuclear Information System (INIS)

    Carriero, Alessandro; Magarelli, Nicola; Gatta, Stefania; Pinto, Dario; Bonomo, Lorenzo; Baratto, Michele; Scapati, Carmelo

    1997-01-01

    The aim of this work was to optimize the magnetic resonance angiography (MRA) technique for the selective study of the pulmonary veins. Twenty patients (13 men and 7 women; mean age: 30.5 years) were examined. MRA was performed with a 1 T superconductive magnet and the 3D time of flight (TOF) technique. Fast sequences (3D FISP : TR 58 ms, TE 6 ms, FA 20 deg, matrix 192 x 256; and 2D FLASH: TR 44 ms, TE 10 ms, FA 30 deg, matrix 192 x 256) were used. Coronal and sagittal images were submitted to MIP processing; presaturation pulses for the pulmonary arteries were located in the mediastinal region. In the right lung 3D TOF on the coronal plane well showed 124 veins, while sagittal images showed 106 veins. In the left lung, 3D TOF on the coronal plane well showed 96 vessels, while sagittal images showed 44 vessels. In the right lung, 2D TOF on the coronal plane well showed 54 veins, while sagittal images showed 36 vessels. In the left lung, 2D TOF on the coronal plane well showed 22 vessels, while sagittal images showed 21 vessels. Therefore 3D TOF yielded better than 2D TOF (p<0.05). To conclude, 3D TOF with contrast agent administration is a useful tool to study the pulmonary veins; those with a larger caliber are better depicted and the integration of coronal and sagittal images depicts more veins

  3. Rapid identification of microorganisms from positive blood cultures by MALDI-TOF mass spectrometry subsequent to very short-term incubation on solid medium.

    Science.gov (United States)

    Idelevich, E A; Schüle, I; Grünastel, B; Wüllenweber, J; Peters, G; Becker, K

    2014-10-01

    Rapid identification of the causative microorganism is important for appropriate antimicrobial therapy of bloodstream infections. Bacteria from positive blood culture (BC) bottles are not readily available for identification by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). Lysis and centrifugation procedures suggested for direct MALDI-TOF MS from positive BCs without previous culture are associated with additional hands-on processing time and costs. Here, we describe an alternative approach applying MALDI-TOF MS from bacterial cultures incubated very briefly on solid medium. After plating of positive BC broth on Columbia blood agar (n = 165), MALDI-TOF MS was performed after 1.5, 2, 3, 4, 5, 6, 7, 8, 12 and (for control) 24 h of incubation until reliable identification to the species level was achieved (score ≥2.0). Mean incubation time needed to achieve species-level identification was 5.9 and 2.0 h for Gram-positive aerobic cocci (GPC, n = 86) and Gram-negative aerobic rods (GNR, n = 42), respectively. Short agar cultures with incubation times ≤2, ≤4, ≤6, ≤8 and ≤12 h yielded species identification in 1.2%, 18.6%, 64.0%, 96.5%, 98.8% of GPC, and in 76.2%, 95.2%, 97.6%, 97.6%, 97.6% of GNR, respectively. Control species identification at 24 h was achieved in 100% of GPC and 97.6% of GNR. Ethanol/formic acid protein extraction performed for an additional 34 GPC isolates cultivated from positive BCs showed further reduction in time to species identification (3.1 h). MALDI-TOF MS using biomass subsequent to very short-term incubation on solid medium allows very early and reliable bacterial identification from positive BCs without additional time and cost expenditure. © 2014 The Authors Clinical Microbiology and Infection © 2014 European Society of Clinical Microbiology and Infectious Diseases.

  4. Environmental assessment for the deactivation of the N Reactor facilities. Revision 1

    International Nuclear Information System (INIS)

    1994-11-01

    This environmental assessment (EA) provides information for the US Department of Energy (DOE) to decide whether the Proposed Action for the N Reactor facilities warrants a Finding of No Significant Impact or requires the preparation of an environmental impact statement (EIS). The EA describes current conditions at the N Reactor facilities, the need to take action at the facilities, the elements of the Proposed Action and alternatives, and the potential environmental impacts. The N Reactor facilities are currently in a surveillance and maintenance program, and will eventually be decontaminated and decommissioned (D and D). Operation and maintenance of the facilities resulted in conditions that could adversely impact human health or the environment if left as is until final D and D. The Proposed Action would deactivate the facilities to remove the conditions that present a potential threat to human health and the environment and to reduce surveillance and maintenance requirements. The action would include surveillance and maintenance after deactivation. Deactivation would take about three years and would involve about 80 facilities. Surveillance and maintenance would continue until final D and D, which is expected to be complete for all facilities except the N Reactor itself by the year 2018

  5. MALDI-TOF MS in the Microbiology Laboratory: Current Trends.

    Science.gov (United States)

    Schubert, Sören; Kostrzewa, Markus

    2017-01-01

    Within less than a decade matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has become a gold standard for microbial identification in clinical microbiology laboratories. Besides identification of microorganisms the typing of single strains as well as the antibiotic and antimycotic resistance testing has come into focus in order to speed up the microbiological diagnostic. However, the full potential of MALDI-TOF MS has not been tapped yet and future technological advancements will certainly expedite this method towards novel applications and enhancement of current practice. So, the following chapter shall be rather a brainstorming and forecast of how MALDI-TOF MS will develop to influence clinical diagnostics and microbial research in the future. It shall open up the stage for further discussions and does not claim for overall validity.

  6. Towards the high-accuracy determination of the 238U fission cross section at the threshold region at CERN – n_TOF

    Directory of Open Access Journals (Sweden)

    Diakaki M.

    2016-01-01

    Full Text Available The 238U fission cross section is an international standard beyond 2 MeV where the fission plateau starts. However, due to its importance in fission reactors, this cross-section should be very accurately known also in the threshold region below 2 MeV. The 238U fission cross section has been measured relative to the 235U fission cross section at CERN – n_TOF with different detection systems. These datasets have been collected and suitably combined to increase the counting statistics in the threshold region from about 300 keV up to 3 MeV. The results are compared with other experimental data, evaluated libraries, and the IAEA standards.

  7. Mechanical valve at pulmonary site in adult TOF & absent pulmonary valve

    Directory of Open Access Journals (Sweden)

    Aayush Goyal

    2017-09-01

    Full Text Available Absent pulmonary valve syndrome (APVS is a rare congenital heart disease. Tetralogy of Fallot (TOF with APVS is a rare variation of TOF. These patients are commonly cyanotic at birth. Respiratory complaints predominate due to airway compression by dilated pulmonary arteries. Commonest age of presentation is infancy with anecdotal adult case-reports. Surgical treatment requires establishing unobstructed competent right ventricular outflow tract (RVOT often with monocusp or conduits. We present a novel technique of rendering RVOT competent by implanting a tilting disc mechanical prosthesis in a rare adult TOF with APVS.

  8. TOF powder diffractometer on a reactor source

    International Nuclear Information System (INIS)

    Bleif, H.J.; Wechsler, D.; Mezei, F.

    1999-01-01

    Complete text of publication follows. The performance of time-of-flight (TOF) methods on Long Pulse Spallation Sources can be studied at a reactor source. For this purpose a prototype TOF monochromator instrument will be installed at the KFKI reactor in Budapest. The initial setup will be a powder diffractometer with a resolution of δd/d down to 2 x 10 -3 at a wavelength of 1 A. The instrument uses choppers to produce neutron pulses of down to 10 μs FWHM. The optimal neutron source for a chopper instrument is a Long Pulse Spallation Source, but even on a continuous source simulations have shown that this instrument outperforms a conventional crystal monochromator powder diffractometer at high resolution. The main components of the TOF instrument are one double chopper defining the time resolution and two single choppers to select the wavelength range and to prevent frame overlap. For inelastic experiments a further chopper can be added in front of the sample. The neutron guide has a super-mirror coating and a curvature of 3500m. The total flight path is 20m and there are 24 single detectors in backscattering geometry. (author)

  9. Temperature measurements in thermonuclear plasmas; Mesures des temperatures dans les plasmas thermonucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Breton, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The temperatures needed to produce thermonuclear reactions are of the order of several million degrees Kelvin. Devising methods for measuring such temperatures has been the subject of research in many countries. In order to present the problem clearly and to demonstrate its importance, the author reviews the various conditions which must be fulfilled in order that reactions may be qualified as thermonuclear. The relationship between the temperature and the cross-section of the reactions is studied, and it is shown that the notion of temperature in the plasmas is complex, which leads to a consideration of the temperature of the ions and that of the electrons. None of the methods for the temperature measurements is completely satisfactory because of the hypotheses which must be made, and which are seldom fulfilled during high-intensity discharges in the plasmas. In practice it is necessary to use several methods simultaneously. (author) [French] Les temperatures necessaires pour produire des reactions thermonucleaires sont de l'ordre de plusieurs millions de degres Kelvin. Les methodes envisagees pour mesurer ces temperatures font l'objet de recherches dans de nombreux pays. Afin de preciser le probleme et de montrer son importance, l'auteur rappelle les conditions qui doivent etre reunies pour que des reactions puissent etre qualifiees thermonucleaires. Il etudie la relation entre la temperature et la section efficace des reactions et montre que la notion de temperature dans les plasmas est complexe, ce qui amene a considerer la temperature des ions et celle des electrons. Aucune des methodes de mesure des temperatures n'est completement satisfaisante en raison des hypotheses qu'elles exigent et qui sont rarement realisees lors des decharges a haute intensite dans les plasmas. En pratique, il est necessaire d'utiliser plusieurs methodes simultanement. (auteur)

  10. MONSTER: a TOF Spectrometer for beta-delayed Neutron Spetroscopy

    CERN Document Server

    Martinez, T; Castilla, J; Garcia, A R; Marin, J; Martinez, G; Mendoza, E; Santos, C; Tera, F; Jordan, M D; Rubio, B; Tain, J L; Bhattacharya, C; Banerjee, K; Bhattacharya, S; Roy, P; Meena, J K; Kundu, S; Mukherjee, G; Ghosh, T K; Rana, T K; Pandey, R; Saxena, A; Behera, B; Penttila, H; Jokinen, A; Rinta-Antila, S; Guerrero, C; Ovejero, M C; Villamarin, D; Agramunt, J; Algora, A

    2014-01-01

    Beta-delayed neutron (DN) data, including emission probabilities, P-n, and energy spectrum, play an important role in our understanding of nuclear structure, nuclear astrophysics and nuclear technologies. A MOdular Neutron time-of-flight SpectromeTER (MONSTER) is being built for the measurement of the neutron energy spectra and branching ratios. The TOF spectrometer will consist of one hundred liquid scintillator cells covering a significant solid angle. The MONSTER design has been optimized by using Monte Carlo (MC) techniques. The response function of the MONSTER cell has been characterized with mono-energetic neutron beams and compared to dedicated MC simulations.

  11. Design tool for TOF and SL based 3D cameras.

    Science.gov (United States)

    Bouquet, Gregory; Thorstensen, Jostein; Bakke, Kari Anne Hestnes; Risholm, Petter

    2017-10-30

    Active illumination 3D imaging systems based on Time-of-flight (TOF) and Structured Light (SL) projection are in rapid development, and are constantly finding new areas of application. In this paper, we present a theoretical design tool that allows prediction of 3D imaging precision. Theoretical expressions are developed for both TOF and SL imaging systems. The expressions contain only physically measurable parameters and no fitting parameters. We perform 3D measurements with both TOF and SL imaging systems, showing excellent agreement between theoretical and measured distance precision. The theoretical framework can be a powerful 3D imaging design tool, as it allows for prediction of 3D measurement precision already in the design phase.

  12. Secondary metabolite profiling of Curcuma species grown at different locations using GC/TOF and UPLC/Q-TOF MS.

    Science.gov (United States)

    Lee, Jueun; Jung, Youngae; Shin, Jeoung-Hwa; Kim, Ho Kyoung; Moon, Byeong Cheol; Ryu, Do Hyun; Hwang, Geum-Sook

    2014-07-04

    Curcuma, a genus of rhizomatous herbaceous species, has been used as a spice, traditional medicine, and natural dye. In this study, the metabolite profile of Curcuma extracts was determined using gas chromatography-time of flight mass spectrometry (GC/TOF MS) and ultrahigh-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC/Q-TOF MS) to characterize differences between Curcuma aromatica and Curcuma longa grown on the Jeju-do or Jin-do islands, South Korea. Previous studies have performed primary metabolite profiling of Curcuma species grown in different regions using NMR-based metabolomics. This study focused on profiling of secondary metabolites from the hexane extract of Curcuma species. Principal component analysis (PCA) and partial least-squares discriminant analysis (PLS-DA) plots showed significant differences between the C. aromatica and C. longa metabolite profiles, whereas geographical location had little effect. A t-test was performed to identify statistically significant metabolites, such as terpenoids. Additionally, targeted profiling using UPLC/Q-TOF MS showed that the concentration of curcuminoids differed depending on the plant origin. Based on these results, a combination of GC- and LC-MS allowed us to analyze curcuminoids and terpenoids, the typical bioactive compounds of Curcuma, which can be used to discriminate Curcuma samples according to species or geographical origin.

  13. Secondary Metabolite Profiling of Curcuma Species Grown at Different Locations Using GC/TOF and UPLC/Q-TOF MS

    Directory of Open Access Journals (Sweden)

    Jueun Lee

    2014-07-01

    Full Text Available Curcuma, a genus of rhizomatous herbaceous species, has been used as a spice, traditional medicine, and natural dye. In this study, the metabolite profile of Curcuma extracts was determined using gas chromatography-time of flight mass spectrometry (GC/TOF MS and ultrahigh-performance liquid chromatography–quadrupole time-of-flight mass spectrometry (UPLC/Q-TOF MS to characterize differences between Curcuma aromatica and Curcuma longa grown on the Jeju-do or Jin-do islands, South Korea. Previous studies have performed primary metabolite profiling of Curcuma species grown in different regions using NMR-based metabolomics. This study focused on profiling of secondary metabolites from the hexane extract of Curcuma species. Principal component analysis (PCA and partial least-squares discriminant analysis (PLS-DA plots showed significant differences between the C. aromatica and C. longa metabolite profiles, whereas geographical location had little effect. A t-test was performed to identify statistically significant metabolites, such as terpenoids. Additionally, targeted profiling using UPLC/Q-TOF MS showed that the concentration of curcuminoids differed depending on the plant origin. Based on these results, a combination of GC- and LC-MS allowed us to analyze curcuminoids and terpenoids, the typical bioactive compounds of Curcuma, which can be used to discriminate Curcuma samples according to species or geographical origin.

  14. Rocuronium: automatic infusion versus manual administration with TOF monitorisation.

    Science.gov (United States)

    Ozturk Arikan, Fatma Gulcin; Turan, Guldem; Ozgultekin, Asu; Sivrikaya, Zubeyir; Cosar, Bekir Cem; Onder, Dondu Nisa

    2016-10-01

    TOF (train-of-four) monitoring provides objective data in application of neuromuscular blocking agent. Thus, applicator-based differences are eliminated and optimum muscle relaxation is maintained during operation. In the present study, we aimed to compare the effects of target-controlled infusion system and standard TOF monitoring, on use of rocuronium. ASA I-II patients, who were aged between 18 and 75 years and scheduled for elective abdominal surgery at Haydarpaşa Numune Training and Research Hospital, were enrolled in the study. In order to evaluate neuromuscular blockade, the patients in Group 1 were connected to the acceleromyography device of the target-controlled infusion pump (Veryark-CLMRIS-I-China) while the ones in Group 2 were connected to the routinely used acceleromyography device (TOF Watch SX). There was no significant difference between groups regarding patient characteristics, the durations of anaesthesia and surgery, quality of intubation, time to extubation and time to recovery (TOF ratio of 0.9). Intubation time was significantly longer in Group 1 (Automated group) as compared to Group 2 (Control group) (p rocuronium amount used in Group 1 was found to be significantly higher than the amount used in Group 2 (p rocuronium was administered via automatical infusion pump during anaesthesia.

  15. Graphene Oxide as a Novel Evenly Continuous Phase Matrix for TOF-SIMS.

    Science.gov (United States)

    Cai, Lesi; Sheng, Linfeng; Xia, Mengchan; Li, Zhanping; Zhang, Sichun; Zhang, Xinrong; Chen, Hongyuan

    2017-03-01

    Using matrix to enhance the molecular ion signals for biomolecule identification without loss of spatial resolution caused by matrix crystallization is a great challenge for the application of TOF-SIMS in real-world biological research. In this report, graphene oxide (GO) was used as a matrix for TOF-SIMS to improve the secondary ion yields of intact molecular ions ([M + H] + ). Identifying and distinguishing the molecular ions of lipids (m/z >700) therefore became straightforward. The spatial resolution of TOF-SIMS imaging could also be improved as GO can form a homogeneous layer of matrix instead of crystalline domain, which prevents high spatial resolution in TOF-SIMS imaging. Lipid mapping in presence of GO revealed the delicate morphology and distribution of single vesicles with a diameter of 800 nm. On GO matrix, the vesicles with similar shape but different chemical composition could be distinguished using molecular ions. This novel matrix holds potentials in such applications as the analysis and imaging of complex biological samples by TOF-SIMS. Graphical Abstract ᅟ.

  16. Susceptibility-weighted angiography (SWAN) of cerebral veins and arteries compared to TOF-MRA

    International Nuclear Information System (INIS)

    Boeckh-Behrens, T.; Lutz, J.; Lummel, N.; Burke, M.; Wesemann, T.; Schöpf, V.; Brückmann, H.; Linn, J.

    2012-01-01

    Problem: High resolution, non-contrast imaging of both cerebral veins and arteries by use of gradient echo T2 star weighted angiography (SWAN) is a new method for susceptibility-weighted imaging with short acquisition times. We assessed the potential of this sequence for the depiction of both cerebral veins and arteries. Methods: 15 healthy volunteers were included in the study. MRI was performed on a 3 T MR scanner using the following sequences: (1) a 3D multi-echo gradient echo T2 star weighted angiography (SWAN), (2) an arterial 3D TOF MR angiography and (3) a venous 2D TOF. With regard to the SWAN sequence, both MinIP and MIP images were reconstructed and systematically compared to MIP reconstructions of the artTOF and the venTOF. To suggest possible clinical implications of our findings, we additionally included two illustrative cases. Results: With regard to the visualization of the cerebral veins, the MinIP reconstructions of the SWAN sequence were considerably superior compared to the venTOF. Concerning the depiction of the main segments of the big cerebral arteries the value of the MIP reconstructions of the SWAN was comparable to that of the artTOF with limitations in the homogenity and in the depiction of smaller arteries. Conclusions: SWAN allows for high-resolution visualization of both cerebral veins and arteries in one sequence without application of contrast agent and with significantly shortened scan time compared to the combined scan time of TOF-MRA and TOF-MRV. By use of either MinIP or MIP reconstructions, the arteries can be distinguished from the veins.

  17. Gas loop - continuous measurement of thermal and fast neutron fluxes; Boucle a gaz - mesure continue de flux de neutrons thermiques et rapides

    Energy Technology Data Exchange (ETDEWEB)

    Droulers, Y; Pleyber, G; Sciers, P; Maurin, G [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1964-07-01

    The measurement method described in this report can be applied both to thermal and fast neutron fluxes. A description is given of two practical applications in each of these two domains. This method is particularly suitable for measurements carried out on 'loop' type equipment. The measurement of the relative flux variations are carried out with an accuracy of 5 per cent. The choice of the shape of the gas circuit leaves a considerable amount of liberty for the adaptation of the measurement circuit to the experimental conditions. (authors) [French] La methode de mesure defrite dans ce rapport s1 applique aussi bien au flux de neutrons thermiques, qu'au flux de neutrons rapides. On donne la description de deux realisations pratiques dans chacun de ces domaines. Cette methode est particulierement adaptee a des mesures effectuees sur des dispositifs du type 'boucle'. La mesure des variations relatives de flux se fait avec une precision de 5 pour cent. Le choix de la configuration du circuit gazeux donne une grande souplesse dans l'adaptation du circuit de mesure aux conditions experimentales. (auteurs)

  18. New Sensors for Cultural Heritage Metric Survey: The ToF Cameras

    Directory of Open Access Journals (Sweden)

    Filiberto Chiabrando

    2011-12-01

    Full Text Available ToF cameras are new instruments based on CCD/CMOS sensors which measure distances instead of radiometry. The resulting point clouds show the same properties (both in terms of accuracy and resolution of the point clouds acquired by means of traditional LiDAR devices. ToF cameras are cheap instruments (less than 10.000 € based on video real time distance measurements and can represent an interesting alternative to the more expensive LiDAR instruments. In addition, the limited weight and dimensions of ToF cameras allow a reduction of some practical problems such as transportation and on-site management. Most of the commercial ToF cameras use the phase-shift method to measure distances. Due to the use of only one wavelength, most of them have limited range of application (usually about 5 or 10 m. After a brief description of the main characteristics of these instruments, this paper explains and comments the results of the first experimental applications of ToF cameras in Cultural Heritage 3D metric survey.  The possibility to acquire more than 30 frames/s and future developments of these devices in terms of use of more than one wavelength to overcome the ambiguity problem allow to foresee new interesting applications.

  19. Diseño y validación de un radar CW-FM a 94 GHz

    OpenAIRE

    Varela Agrelo, David

    2013-01-01

    Diseño y validación de un radar CW-FM a 9g GHz 94 GHz CW-FM radar design and mesurement campaign validation. Desarrollo de un radar CW-FM a 94GHz y verificación de los resultados obtenidos durante la etapa de medidas. Desevolupament d'un radar CW-FM a 94GHz i verificació dels resultat obteinguts durante l'etapa de mesures.

  20. First records of thermal neutrons with the spectrometer for time of flight (TOF) in the RP-10 Nuclear Reactor

    International Nuclear Information System (INIS)

    Munive, M.; Baltuano, O; Soto, C; Ravello, Y

    2002-01-01

    To obtain the first spectrum of an emergent beam of neutrons of a nuclear reactor is the main parameter of the characterization in the use of this reactor; one of ways to get this spectrum is for the technique of time of flight, TOF, which registers the time that a neutron need to cover a certain distance, associating this time then to the kinetic energy of the neutron. The kinetic study of the beam of neutrons is carried out on neutron pulses that are generated by a revolving choke called Chopper; and the analysis in the time of the detected pulses is carried out for a system MCS. Using this technique it is achieved the record of the spectra in energy, or in wavelength , of the irradiation facilities No 2 and 4, and of the exit N o 5 of the thermal column of the Nuclear Reactor RP-10 of the Nuclear Center Oscar de la Guerra RACSO, Peru (au)

  1. Measurement of the electronic density of ionised media by hyper frequency methods; Mesure de la densite electronique des milieux ionises par des methodes hyperfrequences

    Energy Technology Data Exchange (ETDEWEB)

    Consoli, T [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Within the limits of the I.N.S.T.N. courses on plasmas, this analytical study summarizes the articles quoted in the references on hyper-frequency techniques for the measurement of electronic density of an ionised gas. It is neither exhaustive nor complete and further details may be obtained by referring to the works mentioned. The first part, devoted to the theoretical side, concert the propagation of electromagnetic waves ionised media and the excitation of stationary raves in electromagnetic cavities. The second part deals with the measurement techniques themselves. It includes those techniques which hare become classic, and also more recent ones being developed in various laboratories and in the Service of Applied Physics at Saclay. (author) [French] Dans le cadre des cours sur les plasmas a l'l.N.S.T. cette etude d'analyse resume les articles cites en bibliographie sur les techniques hyperfrequences pour la mesure de la densite electronique d'un gas ionise. Elle n'est ni exhaustive, ni complete. Pour plus de details on voudra bien se rapporter aux travaux mentionnes. La premiere partie consacree a des rappels theoriques, concerne la propagation des ondes electromagnetiques dans les milieux ionises et sur l'excitation d'ondes stationnaires dans les cavites electromagnetiques. La seconde se rapporte aux techniques de mesures proprement dites. On a fait figurer dans cette partie des techniques devenues classiques et celles plus recentes en cours d'etudes dans divers laboratoires et au Service de Physique Appliquee a SACLAY. (auteur)

  2. The resolution of TOF low-Q diffractometers: Instrumental, data acquisition and reduction factors

    International Nuclear Information System (INIS)

    Hjelm, R.P. Jr.

    1988-01-01

    The resolution of scattering vector, Q, in small-angle neutron scattering (SANS) measurements derives from uncertainties in scattered neutron wavelength and direction. The manner in which these are manifest on brod-band time-of-flight (TOF) spectrometers at pulsed sources is different from that for instruments using monochromated sources. In TOF instruments the uncertainties arise from the TOF measurement as well as the directional uncertainties due to collimation, finite sample and detector-element size that are present in any small-angle scattering instrument. Further, data from a TOF instrument must be mapped into Q space, and the strategy used to accomplish this affects the final resolution of the measurement. Thus for TOF-SANS instruments the question of resolution is more complicated than for instruments on monochromated sources. There is considerable flexibility in TOF data acquisition and Q mapping that can be utilized to optimize for intensity and Q resolution requirements of a particular measurement. In this work, present understanding of the effects of instrument geometry, TOF data acquisition and Q mapping strategies on the precision of the measurement is outlined. The goal is to establish guidelines on the best manner in which a particular measurement can be set up. Toward this end some new aspects are presented of optimal Q-mapping procedures, the effect of inelastic scattering on the measurement, and the calculation of instrument resolution functions. Some of these ideas are tested by comparison of simulations with measurement. (orig.)

  3. Initial experience with 3T 3D-TOF MRA in the diagnosis of intracranial aneurysms

    International Nuclear Information System (INIS)

    Senba, Yoshiki; Takahashi, Shizue; Matsubara, Ichiro; Sadamoto, Kazuhiko; Miki, Hitoshi; Mochizuki, Teruhito

    2006-01-01

    We assessed the value of 3T 3D-time of flight (TOF) MR angiography (MRA) in the diagnosis of intracranial aneurysms compared with 1.5T 3D-TOF MRA. Twenty-one patients with 22 aneurysms underwent MRA at 1.5T and 3T. Images were interpreted by two radiologists. Each of nine aneurysms that had been considered ''definite'' at 1.5T 3D-TOF MRA were considered ''definite'' at 3T 3D-TOF MRA. Seven aneurysms that had been considered ''suspicious'' at 1.5T MRA were considered ''definite'' at 3T. And four aneurysms that had been considered ''suspicious'' at 1.5T were considered ''negative'' at 3T. We concluded that 3T 3D-TOF MRA is superior to 1.5T 3D-TOF MRA in the diagnosis of intracranial aneurysms. (author)

  4. MALDI-TOF-MS with PLS Modeling Enables Strain Typing of the Bacterial Plant Pathogen Xanthomonas axonopodis

    Science.gov (United States)

    Sindt, Nathan M.; Robison, Faith; Brick, Mark A.; Schwartz, Howard F.; Heuberger, Adam L.; Prenni, Jessica E.

    2018-02-01

    Matrix-assisted desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) is a fast and effective tool for microbial species identification. However, current approaches are limited to species-level identification even when genetic differences are known. Here, we present a novel workflow that applies the statistical method of partial least squares discriminant analysis (PLS-DA) to MALDI-TOF-MS protein fingerprint data of Xanthomonas axonopodis, an important bacterial plant pathogen of fruit and vegetable crops. Mass spectra of 32 X. axonopodis strains were used to create a mass spectral library and PLS-DA was employed to model the closely related strains. A robust workflow was designed to optimize the PLS-DA model by assessing the model performance over a range of signal-to-noise ratios (s/n) and mass filter (MF) thresholds. The optimized parameters were observed to be s/n = 3 and MF = 0.7. The model correctly classified 83% of spectra withheld from the model as a test set. A new decision rule was developed, termed the rolled-up Maximum Decision Rule (ruMDR), and this method improved identification rates to 92%. These results demonstrate that MALDI-TOF-MS protein fingerprints of bacterial isolates can be utilized to enable identification at the strain level. Furthermore, the open-source framework of this workflow allows for broad implementation across various instrument platforms as well as integration with alternative modeling and classification algorithms.

  5. Flavonoids as matrices for MALDI-TOF mass spectrometric analysis of transition metal complexes

    Science.gov (United States)

    Petkovic, Marijana; Petrovic, Biljana; Savic, Jasmina; Bugarcic, Zivadin D.; Dimitric-Markovic, Jasmina; Momic, Tatjana; Vasic, Vesna

    2010-02-01

    Matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a suitable method for the analysis of inorganic and organic compounds and biomolecules. This makes MALDI-TOF MS convenient for monitoring the interaction of metallo-drugs with biomolecules. Results presented in this manuscript demonstrate that flavonoids such as apigenin, kaempferol and luteolin are suitable for MALDI-TOF MS analysis of Pt(II), Pd(II), Pt(IV) and Ru(III) complexes, giving different signal-to-noise ratios of the analyte peak. The MALDI-TOF mass spectra of inorganic complexes acquired with these flavonoid matrices are easy to interpret and have some advantages over the application of other commonly used matrices: a low number of matrix peaks are detectable and the coordinative metal-ligand bond is, in most cases, preserved. On the other hand, flavonoids do not act as typical matrices, as their excess is not required for the acquisition of MALDI-TOF mass spectra of inorganic complexes.

  6. Mesure de la fraction d'evenements a quatre quarks dans les desintegrations multihadroniques du boson Z au LEP

    Science.gov (United States)

    Lefebvre, Eric

    Cette thèse propose de tester la Chromodynamique Quantique (QCD) en effectuant une mesure précise d'une des trois constantes fondamentales du groupe de symétrie SU(3) utilisé pour décrire la physique des interactions fortes. Cette constante fondamentale, appelée TF, est reliée à certains états finaux spécifiques des désintégrations du Z0. Ces états apparaissent sous forme de perturbations du deuxième ordre en as et sont illustrés par des diagrammes de Feynman. À cet ordre, la chromodynamique prévoit deux types de diagrammes de Feynman distincts; le premier contient, un quark, un antiquark et deux gluons, et le second, deux quarks et deux antiquarks. La constante TF est directement proportionnelle à la fraction d'événements à deux quarks et deux antiquarks qui est l'objet de notre mesure. Notre mesure est fondée sur l'étude des événements à quatre partons dans l'état final. Ces quatre partons, en s'hadronisant, produisent quatre jets de particules qui peuvent être détectés expérimentalement et identifiés à l'aide d'algorithmes de reconstruction des jets. Des observables angulaires nous permettent de faire une discrimination parmi les états finaux de la désintégration du Z0, et ainsi déterminer la valeur de la fraction d'événements à deux quarks et deux antiquarks fq. Cette fraction peut s'exprimer par le rapport de la fraction observée expérimentalement fexq sur la fraction théorique fthq , R4q=fex qfthq. Afin d'améliorer la mesure de cette fraction et de diminuer le bruit causé par une contamination des événements d'ordres supérieurs, nous avons développe une méthode d'extrapolation. Cette méthode s'appuie sur la caractérisation de l'espace de phase des événements, exprimée par les paramètres yij. Les mesures de R4q que nous obtenons sont: R4q=2,27+0,29 -0,56 à l'aide d'une méthode conventionnelle avec la condition de sélection y34 > 0,020 > y45, et R4q=1,22+0,56 -0,71 à l'aide de notre méthode d

  7. Notes on the measurement of stress by resistance gauges in the presence of a magnetic field; Note sur les mesures de contraintes par jauges a fil resistant en presence de champ magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Armand, G; Lapujoulade, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1961-07-01

    The technique of stress measurement by resistance gauges is well known. Although it is not yet perfect it possesses many advantages and shows great possibilities. In the presence of a magnetic field the measurement is perturbed by certain phenomena, and we have undertaken to calculate their order of magnitude with a view to establishing the error involved in the measurement. Our problem was to measure the stresses on the various parts of the magnet in the synchrotron Saturne. It is known that the induction passes from a value of about nil to 15000 gauss in 0.8 second, and returns to zero in the same time interval; this cycle recurs every 3.2 seconds. In order to isolate the effects the problem of measurements in a static field will be examined first, after which the results obtained will be extended to the case of dynamic fields. (author) [French] La technique de mesure de contraintes par jauges a fil resistant est bien connue. Elle presente de nombreux avantages, beaucoup de possibilites, bien que n'etant pas encore parfaite. En presence de champ magnetique, la mesure est perturbee par un certain nombre de phenomenes dont nous avons ete conduits a chiffrer l'ordre de grandeur afin de connaitre l'erreur commise lors de la mesure. Precisons qu'il s'agissait pour nous de mesurer les contraintes sur les differents organes de l'aimant du synchrotron Saturne. L'on sait que la valeur de l'induction au droit de l'entrefer passe d'une valeur sensiblement nulle a 15000 gauss en 0,8 secondes, pour revenir ensuite a zero pendant un temps egal au precedent; le cycle ci-dessus se reproduit toutes les 3,2 secondes. Afin de separer les effets, nous examinerons d'abord le probleme des mesures en champ statique puis nous etendrons les resultats obtenus au cas des champs dynamiques. (auteur)

  8. Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations)

    Energy Technology Data Exchange (ETDEWEB)

    Sartory, M [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    In the setting of the realization of a set of installations permitting of the measures of coincidences between sorted radiances according to their energies, an installation understanding a proportional counter and a scintillation counter has been constructed and optimized. It has been used to do some measures of coincidences between X{sub K} photons and photons {gamma} issued at the time of the radioactive transformation of the selenium 75 (electronic capture). The efficiency of the proportional meter has been determined roughly. Besides, a proportional counter of solid angle neighboring of 4{pi} was able to achieve measures of coincidences while only doing one selection of amplitudes: indeed, the simultaneity of the detection of two radiances appear by an impulse whose amplitude is the sum of the amplitudes of the impulses resulting from each of the studied radiations. This method, applied to the coincidences between X-rays, permitted to bring the information on the diagram of decay of the arsenic 73. Besides, the coefficient of internal conversion of a consecutive transition to this decay has been valued. (author) [French] Dans le cadre de la realisation d'une serie de montages permettant des mesures de coincidences entre rayonnements tries d'apres leurs energies, un montage comprenant un compteur proportionnel et un compteur a scintillations a ete construit et mis au point. Il a ete utilise pour effectuer quelques mesures de coincidences entre photons X{sub K} et photons {gamma} emis lors de la transformation radioactive du selenium 75 (capture electronique). L'efficacite du compteur proportionnel a ete approximativement determinee. De plus, un compteur proportionnel d'angle solide voisin de 4{pi} a pu etre utilise pour realiser des mesures de coincidences en n'effectuant qu'une selection d'amplitudes: en effet, la simultaneite de la detection de deux rayonnements se manifeste par une impulsion dont l'amplitude est la somme des amplitudes des impulsions

  9. La mesure de pluie par radar : du calibrage par des pluviomètres vers l'interprétation physique des images

    OpenAIRE

    ANDRIEU, H

    2002-01-01

    Cet article retrace l'évolution des méthodes de traitement des images radar pour la mesure des précipitations. Les études ont tout donné la priorité au calibrage des images radar par des données pluviométriques de façon à bénéficier des avantages supposés de chaque capteur : représentativité ponctuelle du pluviomètre, continuité spatiale de l'image radar. Bien que positifs, les résultats obtenus ont mis en évidence la nécessité d'une détection et d'une correction des principales sources d'err...

  10. Developpement d'une methode calorimetrique de mesure des pertes ac pour des rubans supraconducteurs a haute temperature critique

    Science.gov (United States)

    Dolez, Patricia

    Le travail de recherche effectue dans le cadre de ce projet de doctorat a permis la mise au point d'une methode de mesure des pertes ac destinee a l'etude des supraconducteurs a haute temperature critique. Pour le choix des principes de cette methode, nous nous sommes inspires de travaux anterieurs realises sur les supraconducteurs conventionnels, afin de proposer une alternative a la technique electrique, presentant lors du debut de cette these des problemes lies a la variation du resultat des mesures selon la position des contacts de tension sur la surface de l'echantillon, et de pouvoir mesurer les pertes ac dans des conditions simulant la realite des futures applications industrielles des rubans supraconducteurs: en particulier, cette methode utilise la technique calorimetrique, associee a une calibration simultanee et in situ. La validite de la methode a ete verifiee de maniere theorique et experimentale: d'une part, des mesures ont ete realisees sur des echantillons de Bi-2223 recouverts d'argent ou d'alliage d'argent-or et comparees avec les predictions theoriques donnees par Norris, nous indiquant la nature majoritairement hysteretique des pertes ac dans nos echantillons; d'autre part, une mesure electrique a ete realisee in situ dont les resultats correspondent parfaitement a ceux donnes par notre methode calorimetrique. Par ailleurs, nous avons compare la dependance en courant et en frequence des pertes ac d'un echantillon avant et apres qu'il ait ete endommage. Ces mesures semblent indiquer une relation entre la valeur du coefficient de la loi de puissance modelisant la dependance des pertes avec le courant, et les inhomogeneites longitudinales du courant critique induites par l'endommagement. De plus, la variation en frequence montre qu'au niveau des grosses fractures transverses creees par l'endommagement dans le coeur supraconducteur, le courant se partage localement de maniere a peu pres equivalente entre les quelques grains de matiere

  11. Transmutation in ADS and Needs for Nuclear Data, with an introduction to the n-TOF at CERN

    International Nuclear Information System (INIS)

    Gonzalez, E.; Embid, M.; Fernandez, R.; Garcia, J.; Villamarin, D.

    1999-01-01

    Transmutation can help in the nuclear waste problem by reducing seriously the life and amount of the most dangerous isotopes (radiotoxicity, heat, packing volume and neutron multiplication reductions). ADS are one of the best technologies for nuclear waste transmutation at large scale. Although enough information is available to prepare conceptual designs and make assessments on their performance, a large R and D campaign is required to obtain the precision data required to optimize the detailed engineering design and refine our expectations calculations on waste reduction by the different transmutation strategies being proposed. In particular a large R and D effort is required in nuclear physics, where fundamental differential measurements and integral verification experiments are required. In this sense, the PS213 n-TOF at CERN PS (At Switzerland) will become one of the largest installations to perform the fundamental differential measurements and a wide international collaboration has been setup to perform the cross section measuring campaign. Similarly, the MUSE and several other experiments taking place and in preparation in Europe, USA and Japan will provide the integral verification

  12. Mesure magnétique du sextupôle rotatif no.1-2083

    CERN Document Server

    Chritin, R; Patron, G; CERN. Geneva. SPS and LEP Division

    1998-01-01

    Lorsque cet aimant nous a été livré afin d'être soumis à un certain nombre de mesures, ses caractéristiques connues se limitaient à celles situées dans l'annexe 1. Il correspond à des sextupôles, INT 2170254 AB L orientables récupérés de l'ancienn

  13. MALDI-TOF Baseline Drift Removal Using Stochastic Bernstein Approximation

    Directory of Open Access Journals (Sweden)

    Howard Daniel

    2006-01-01

    Full Text Available Stochastic Bernstein (SB approximation can tackle the problem of baseline drift correction of instrumentation data. This is demonstrated for spectral data: matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF data. Two SB schemes for removing the baseline drift are presented: iterative and direct. Following an explanation of the origin of the MALDI-TOF baseline drift that sheds light on the inherent difficulty of its removal by chemical means, SB baseline drift removal is illustrated for both proteomics and genomics MALDI-TOF data sets. SB is an elegant signal processing method to obtain a numerically straightforward baseline shift removal method as it includes a free parameter that can be optimized for different baseline drift removal applications. Therefore, research that determines putative biomarkers from the spectral data might benefit from a sensitivity analysis to the underlying spectral measurement that is made possible by varying the SB free parameter. This can be manually tuned (for constant or tuned with evolutionary computation (for .

  14. Neutrons are flying

    CERN Multimedia

    2000-01-01

    View of the n_TOF tube with members of the design and construction team of the facility(from left to right: R. Magnin/LHC, E. Radermacher/EP, P. Cennini/EP and R. Cappi/PS). A new experimental facility was inaugurated at CERN on Wednesday 8 November. The neutron Time Of Flight (n_TOF) facility received its first protons from the PS at 10:55. With an intensity of 1 x 1011 protons per cycle on the n_TOF target, an intense neutron beam has been produced at CERN for the first time, opening the door to many new avenues of research including, for example, neutron induced cross-section measurements. The facility is an offspring of the work by Carlo Rubbia and his group on the novel idea of an Energy Amplifier. The basic idea was successfully tested at the PS with the FEAT experiment and later with the TARC experiment, where the feasibility of transmutation of long-lived products by Adiabatic Resonance Crossing (ARC) was confirmed. This led to the possibility of radio-isotope production for medical applications, fo...

  15. Silicon P.I.N. Junctions used for studies of radiation damage; Etude de l'irradiation aux neutrons rapides du silicium au moyen de jonctions P.I.N

    Energy Technology Data Exchange (ETDEWEB)

    Lanore, J. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-06-01

    Irradiation of silicon P.I.N. junction has been studied primarily for the purpose of developing a radiation damage dosimeter, but also for the purpose of investigating silicon itself. It is known that the rate of recombination of electrons and holes is a linear function of defects introduced by neutron irradiation. Two methods have been used to measure that rate of recombination: forward characteristic measurements, recovery time measurements. In order to explain how these two parameters depend on recombination rate we have given a theory of the P.I.N. junction. We have also given an idea of the carrier lifetime dependence versus temperature. Annealing effects in the range of 70 to 700 K have also been studied, we found five annealing stages with corresponding activation energies. As an application for these studies, we developed a radiation damage dosimeter with which we made several experiments in facilities such as Naiade or Marias. (author) [French] L'irradiation de structures P.I.N. etait faite dans le but d'etudier principalement la mise au point d'un dosimetre a ''radiation damage'' et aussi pour etudier plus profondement le silicium lui-meme. On sait que le taux de recombinaison electrons-trous est une fonction lineaire du taux de defauts introduits par irradiation aux neutrons. Deux methodes ont ete utilisees pour atteindre ce taux de recombinaison: mesures de la caracteristique directe, mesures du temps de retournement. Pour expliquer de quelle facon ces parametres dependent du taux de recombinaison. Nous avons donne une theorie de la jonction P.I.N. Nous avons aussi donne l'allure des variations du temps de vie des porteurs en fonction de la temperature. Nous avons d'autre part effectue des recuits entre 70 et 700 K, domaine dans lequel nous avons trouve cinq etapes de ''guerison'' avec les energies d'activation correspondantes. En application de ces etudes nous avons mis ou point un

  16. Cherenkov TOF PET with silicon photomultipliers

    Science.gov (United States)

    Dolenec, R.; Korpar, S.; Križan, P.; Pestotnik, R.

    2015-12-01

    As previously demonstrated, an excellent timing resolution below 100 ps FWHM is possible in time-of-flight positron emission tomography (TOF PET) if the detection method is based on the principle of detecting photons of Cherenkov light, produced in a suitable material and detected by microchannel plate photomultipliers (MCP PMTs). In this work, the silicon photomultipliers (SiPMs) were tested for the first time as the photodetectors in Cherenkov TOF PET. The high photon detection efficiency (PDE) of SiPMs led to a large improvement in detection efficiency. On the other hand, the time response of currently available SiPMs is not as good as that of MCP PMTs. The SiPM dark counts introduce a new source of random coincidences in Cherenkov method, which would be overwhelming with present SiPM technology at room temperature. When the apparatus was cooled, its performance significantly improved.

  17. TOF-SIMS characterization of planktonic foraminifera

    International Nuclear Information System (INIS)

    Vering, G.; Crone, C.; Bijma, J.; Arlinghaus, H.F.

    2003-01-01

    Oceanic sediment properties that are closely related to former environmental (e.g. climatic) parameters are called 'proxies'. Planktonic foraminifera are small protists which make up part of the plankton. Certain element concentrations, element ratios and isotopic ratios of their calcite shell found in the sediment can be used as proxies reflecting the state of the ocean during the life of the animal; they supply useful information for the reconstruction of environmental parameters. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) was used to examine the inner and outer part of foraminiferal shells, as well as foraminiferal shells dissolved in HCl. High resolution elemental images and mass spectra were obtained from the foraminifera. The data show that TOF-SIMS is a useful technique for determining the elemental distribution and for measuring isotope ratios such as δ 11 B with high precision in a single foraminiferal shell

  18. TOF-SIMS characterization of planktonic foraminifera

    Energy Technology Data Exchange (ETDEWEB)

    Vering, G.; Crone, C.; Bijma, J.; Arlinghaus, H.F

    2003-01-15

    Oceanic sediment properties that are closely related to former environmental (e.g. climatic) parameters are called 'proxies'. Planktonic foraminifera are small protists which make up part of the plankton. Certain element concentrations, element ratios and isotopic ratios of their calcite shell found in the sediment can be used as proxies reflecting the state of the ocean during the life of the animal; they supply useful information for the reconstruction of environmental parameters. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) was used to examine the inner and outer part of foraminiferal shells, as well as foraminiferal shells dissolved in HCl. High resolution elemental images and mass spectra were obtained from the foraminifera. The data show that TOF-SIMS is a useful technique for determining the elemental distribution and for measuring isotope ratios such as {delta}{sup 11}B with high precision in a single foraminiferal shell.

  19. Compton scatter tomography in TOF-PET

    Science.gov (United States)

    Hemmati, Hamidreza; Kamali-Asl, Alireza; Ay, Mohammadreza; Ghafarian, Pardis

    2017-10-01

    Scatter coincidences contain hidden information about the activity distribution on the positron emission tomography (PET) imaging system. However, in conventional reconstruction, the scattered data cause the blurring of images and thus are estimated and subtracted from detected coincidences. List mode format provides a new aspect to use time of flight (TOF) and energy information of each coincidence in the reconstruction process. In this study, a novel approach is proposed to reconstruct activity distribution using the scattered data in the PET system. For each single scattering coincidence, a scattering angle can be determined by the recorded energy of the detected photons, and then possible locations of scattering can be calculated based on the scattering angle. Geometry equations show that these sites lie on two arcs in 2D mode or the surface of a prolate spheroid in 3D mode, passing through the pair of detector elements. The proposed method uses a novel and flexible technique to estimate source origin locations from the possible scattering locations, using the TOF information. Evaluations were based on a Monte-Carlo simulation of uniform and non-uniform phantoms at different resolutions of time and detector energy. The results show that although the energy uncertainties deteriorate the image spatial resolution in the proposed method, the time resolution has more impact on image quality than the energy resolution. With progress of the TOF system, the reconstruction using the scattered data can be used in a complementary manner, or to improve image quality in the next generation of PET systems.

  20. TOF-SIMS Analysis of Red Color Inks of Writing and Printing Tools on Questioned Documents.

    Science.gov (United States)

    Lee, Jihye; Nam, Yun Sik; Min, Jisook; Lee, Kang-Bong; Lee, Yeonhee

    2016-05-01

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a well-established surface technique that provides both elemental and molecular information from several monolayers of a sample surface while also allowing depth profiling or image mapping to be performed. Static TOF-SIMS with improved performances has expanded the application of TOF-SIMS to the study of a variety of organic, polymeric, biological, archaeological, and forensic materials. In forensic investigation, the use of a minimal sample for the analysis is preferable. Although the TOF-SIMS technique is destructive, the probing beams have microsized diameters so that only small portion of the questioned sample is necessary for the analysis, leaving the rest available for other analyses. In this study, TOF-SIMS and attenuated total reflectance Fourier transform infrared (ATR-FTIR) were applied to the analysis of several different pen inks, red sealing inks, and printed patterns on paper. The overlapping areas of ballpoint pen writing, red seal stamping, and laser printing in a document were investigated to identify the sequence of recording. The sequence relations for various cases were determined from the TOF-SIMS mapping image and the depth profile. TOF-SIMS images were also used to investigate numbers or characters altered with two different red pens. TOF-SIMS was successfully used to determine the sequence of intersecting lines and the forged numbers on the paper. © 2016 American Academy of Forensic Sciences.

  1. Theoretical and experimental study of a calorimetric technique for measuring energy deposition in materials caused by complex pile irradiation; Etude theorique et experimentale d'une technique calorimetrique de mesure des depots d'energie dans les materiaux dus au rayonnement complexe de pile

    Energy Technology Data Exchange (ETDEWEB)

    Mas, P; Sciers, P; Droulers, Y [Commissariat a l' Energie Atomique. Centre d' Etudes Nucleaires, 38 - Grenoble (France)

    1962-07-01

    Calorimetric methods may be used to measure gamma fluxes greater than 10{sup 6} r/h near the cores of swimming pool reactors. The theory, design, and properties of isothermal calorimeters are discussed, and experimental results obtained with two types are presented. Measurement of energy deposition in materials and the long term integration of energy depositions are other uses of these devices. Results of measurements on heat deposition in steel and water are given. Fluxes were also measured. (authors) [French] Une premiere partie traite de la theorie des calorimetres isothermes mis en oeuvre au C.K.N. Grenoble. La puissance deposee dans le calorimetre par les flux de rayonnement echauffe celui-ci. L'echauffement est mesure a l'aide d'un thermocouple. On montre que l'on a ainsi une mesure absolue de cette puissance. Une deuxieme partie traite de l'etude experimentale de: deux types d'appareils utilises: leur construction, les resultats experimentaux, leurs utilisations. Trois de celles-ci sont particulierement interessantes: - la mesure des hauts flux gamma, - la mesure du depot d'energie dans les materiaux, - l'integration pendant une longue duree des depots d'energie (un modele de calorimetre a fonctionne a ce jour 2 500 heures et a integre 9 x 10 puissance 10 rads gamma et 6 x 10 puissance 18 neutrons rapides). La troisieme partie est consacree a l'etude des qualites de l'appareil: robustesse, fidelite, precision, sensibilite, gamme de mesure. Enfin dans la derniere partie sont decrites deux applications de la methode calorimetrique a la mesure du depot d'energie dans un acier special et dans l'eau. (auteurs)

  2. Evaluation of MALDI-TOF mass spectrometry for the competitiveness analysis of selected indigenous cowpea (Vigna unguiculata L. Walp.) Bradyrhizobium strains from Kenya.

    Science.gov (United States)

    Ndungu, Samuel Mathu; Messmer, Monika M; Ziegler, Dominik; Thuita, Moses; Vanlauwe, Bernard; Frossard, Emmanuel; Thonar, Cécile

    2018-06-01

    Cowpea N 2 fixation and yield can be enhanced by selecting competitive and efficient indigenous rhizobia. Strains from contrasting agro-ecologies of Kilifi and Mbeere (Kenya) were screened. Two pot experiments were established consisting of 13 Bradyrhizobium strains; experiment 1 (11 Mbeere + CBA + BK1 from Burkina Faso), experiment 2 (12 Kilifi + CBA). Symbiotic effectiveness was assessed (shoot biomass, SPAD index and N uptake). Nodule occupancy of 13 simultaneously co-inoculated strains in each experiment was analyzed by matrix-assisted laser desorption/ionization time of flight (MALDI-TOF) mass spectrometry (MS) to assess competitiveness. Strains varied in effectiveness and competitiveness. The four most efficient strains were further evaluated in a field trial in Mbeere during the 2014 short rains. Strains from bacteroids of cowpea nodules from pot and field experiments were accurately identified as Bradyrhizobium by MALDI-TOF based on the SARAMIS™ database. In the field, abundant indigenous populations 7.10 × 10 3 rhizobia g -1 soil, outcompeted introduced strains. As revealed by MALDI-TOF, indigenous strains clustered into six distinct groups (I, II, III, IV, V and VI), group III were most abundant occupying 80% of nodules analyzed. MALDI-TOF was rapid, affordable and reliable to identify Bradyrhizobium strains directly from nodule suspensions in competition pot assays and in the field with abundant indigenous strains thus, its suitability for future competition assays. Evaluating strain competitiveness and then symbiotic efficacy is proposed in bioprospecting for potential cowpea inoculant strains.

  3. New developments in molecular imaging: positron emission tomography time-of-flight (TOF-PET); Nuevos desarrollos en imagen molecular: Tomografia por Emision de Positrones con Teimpo de Vuelo (TOF-PET)

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar, P.; Couce, B.; Iglesias, A.; Lois, C.

    2011-07-01

    Positron Emission tomography (PET) in increasingly being used in oncology for the diagnosis and staging of disease, as well as in monitoring response to therapy. One of the last advances in PET is the incorporation of Time-of-Flight (TOF) information, which improves the tomographic reconstruction process and subsequently the quality of the final image. In this work, we explain the principles of PET and the fundamentals of TOF-PET. Clinical images are shown in order to illustrate how TOF-PET improves the detectability of small lesions, particularly in patients with high body mass index. (Author) 20 refs.

  4. Elucidating heterogeneity of IgA1 hinge-region O-glycosylation by use of MALDI-TOF/TOF mass spectrometry: role of cysteine alkylation during sample processing.

    Science.gov (United States)

    Franc, Vojtěch; Řehulka, Pavel; Raus, Martin; Stulík, Jiří; Novak, Jan; Renfrow, Matthew B; Šebela, Marek

    2013-10-30

    Determining disease-associated changes in protein glycosylation provides a better understanding of pathogenesis. This work focuses on human immunoglobulin A1 (IgA1), where aberrant O-glycosylation plays a key role in the pathogenesis of IgA nephropathy (IgAN). Normal IgA1 hinge region carries 3 to 6 O-glycans consisting of N-acetylgalactosamine (GalNAc) and galactose (Gal); both sugars may be sialylated. In IgAN patients, some O-glycans on a fraction of IgA1 molecules are Gal-deficient. Here we describe a sample preparation protocol with optimized cysteine alkylation of a Gal-deficient polymeric IgA1 myeloma protein prior to in-gel digestion and analysis of the digest by MALDI-TOF/TOF mass spectrometry (MS). Following a novel strategy, IgA1 hinge-region O-glycopeptides were fractionated by reversed-phase liquid chromatography using a microgradient device and identified by MALDI-TOF/TOF tandem MS (MS/MS). The acquired MS/MS spectra were interpreted manually and by means of our own software. This allowed assigning up to six O-glycosylation sites and demonstration, for the first time, of the distribution of isomeric O-glycoforms having the same molecular mass, but a different glycosylation pattern. The most abundant Gal-deficient O-glycoforms were GalNAc4Gal3 and GalNAc5Gal4 with one Gal-deficient site and GalNAc5Gal3 and GalNAc4Gal2 with two Gal-deficient sites. The most frequent Gal-deficient sites were at Ser230 and/or Thr236. In this work, we studied the O-glycosylation in the hinge region of human immunoglobulin A1 (IgA1). Aberrant glycosylation of the protein plays a key role in the pathogenesis of IgA nephropathy. Thus identification of the O-glycan composition of IgA1 is important for a deeper understanding of the disease mechanism, biomarker discovery and validation, and implementation and monitoring of disease-specific therapies. We developed a new procedure for elucidating the heterogeneity of IgA1 O-glycosylation. After running a polyacrylamide gel

  5. Measurement of Placental Blood Flow with {sup 133}Xe in Normal and Pathological Human Pregnancy; Mesure du Debit Placentaire dans les Grossesses Normales et Pathologiques

    Energy Technology Data Exchange (ETDEWEB)

    Pontonnier, G.; Delmas, H.; Farre, J.; Favretto, R. [Clinique Obstetricale, Hopital de la Grave, Toulouse (France)

    1971-02-15

    practical standpoint, it provides one more element for the surveillance of pregnancies involving high foetal risk and makes it possible to study the action of drugs administered to the mother on placental blood flow. (author) [French] La plupart des auteurs s'accordent a reconnaitre l'importance des alterations de la circulation placentaire dans la genese de la souffrance foetale chronique. Or il n'existait pas jusqu'ici de technique qui permette une evaluation quantitative de l'hemodynamique placentaire. Les auteurs presentent une methode de mesure du debit placentaire qui est une application des radioisotopes a la mesure des debits locaux. Ils utilisent le xenon-133 en solution dans du serum physiologique; ce gaz radioactif presente l'avantage d'etre inerte et instantanement diffusible. Apres localisation radiographique ou ultrasonique du placenta, ils injectent par voie trans-abdominale 50 {mu}Ci de xenon dans le placenta. L'enregistrement de la courbe de clearance du xenon-133 est effectue au moyen d'un detecteur a scintillation. La courbe obtenue est en meme temps enregistree sur un inscripteur lineaire et transmise a un calculateur automatique. Les auteurs ont ainsi realise 111 mesures de debit placentaire: 45 dans des grossesses normales, 59 dans des grossesses pathologiques et 7 apres perfusion medicamenteuse. Les mesures effectuees ont permis pour la premiere fois de chiffrer la valeur du debit placentaire chez la femme. Pour les grossesses normales, entre la 32{sup e} et la 41{sup e} semaine, il est de 145 ml/100 g/min. Les mesures effectuees au cours de grossesses pathologiques (hypertension arterielle, dysgravidie, infection urinaire, diabete, grossesse prolongee) ont montre que celles-ci s'accompagnent d'une diminution du debit placentaire statistiquement significative. L'importance de cette diminution est en rapport avec la clinique et l'etat de l'enfant a la naissance. Cette methode de mesure, facilement reproductible chez la meme femme, presente donc un

  6. Benefits and Impact of Joint Metric of AOA/RSS/TOF on Indoor Localization Error

    Directory of Open Access Journals (Sweden)

    Qing Jiang

    2016-10-01

    Full Text Available The emerging techniques in the Fifth Generation (5G communication system, like the millimeter-Wave (mmWave and massive Multiple Input Multiple Output (MIMO, make it possible to measure the Angle-Of-arrival (AOA, Receive Signal Strength (RSS and Time-Of-flight (TOF by using various types of mobile devices. At the same time, there is always significant interest in the high-precision localization techniques based on the joint metric of AOA/RSS/TOF, which enable one to overcome the drawback of the single metric-based localization. Motivated by this concern, we rely on the Cramer–Rao Lower Bound (CRLB to analyze the localization errors of RSS/AOA, RSS/TOF, AOA/TOF and the Joint Metric of AOA/RSS/TOF (JMART-based localization. The error bounds derived in this paper can be selected as the benchmarking results to evaluate the indoor localization performance. Finally, extensive simulations are conducted to support our claim.

  7. Mesure de la teneur en eau en continu durant le séchage du foin en balles

    OpenAIRE

    Cormier, Étienne

    2008-01-01

    Une mesure en continu et précise de la teneur en eau (TEE) permettrait d'optimiser le séchage du foin dans un séchoir commercial à grande échelle. Pour mesurer la précision des lectures dans ces conditions, un capteur électronique relié à 16 sondes a été utilisé pour estimer la TEE dans un séchoir expérimental. Deux sondes et un thermocouple étaient insérés dans huit couches de foin superposées, de 135 mm d'épaisseur chacune. Les TEE estimées par les sondes ont été comparées à des TEE exactes...

  8. Environmental assessment for the deactivation of the N Reactor facilities

    International Nuclear Information System (INIS)

    1995-05-01

    This environmental assessment (EA) provides information for the US Department of Energy (DOE) to decide whether the Proposed Action for the N Reactor facilities warrants a Finding of No Significant Impact or requires the preparation of an environmental impact statement (EIS). The EA describes current conditions at the N Reactor facilities, the need to take action at the facilities, the elements of the Proposed Action and alternatives, and the potential environmental impacts. As required by the National Environmental Policy Act of 1969 (NEPA), this EA complies with Title 40, Code of Federal Regulations (CFR), parts 1500--1508, ''Regulations for Implementing the Procedural Provisions of NEPA. '' It also implements the ''National Environmental Policy Act; Implementing Procedures and Guidelines'' (10 CFR 1021)

  9. Application of a proportional counter to some particular cases of {alpha} measurements; Applications d'un compteur proportionnel a quelques cas particuliers de mesures {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Ferret, J; Gasc, M T; Le Du, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    I - A measurement method based on {alpha} {gamma} coincidences is used for activity measurements on {sup 241}Am in the presence of a strong {alpha} activity due to Pu. The sensitivity of the apparatus makes it possible to detect: less than 10{sup -7} {mu}C {sup 241}Am in the presence of a Pu activities several hundred times greater. II - The same equipment has been used for {alpha} measurements on {alpha}-emitting sources in the presence of very strong {beta} and {gamma} activities. In particular results are given for {alpha}-activity measurements on powder samples. It is even possible in these conditions, to detect or measure {sup 241}Am. III - The equipment makes possible also: - the absolute calibration of a pure {sup 241}Am source - {sup 237}Np measurements - simultaneous measurements of {alpha}, {beta} and {gamma} activities in solid samples in various forms. IV - The assembly includes a small-size proportional counter operating in conjunction with a {gamma} probe, together with auxiliary electronic equipment (stabilized high voltages, amplifiers, a coincidence unit, a sealer). (authors) [French] I - Une methode de mesures par coincidences {alpha} {gamma} est utilisee pour des mesures d'activite de {sup 241}Am en presence d'activite {alpha} (due au Pu) importante. -La sensibilite de l'appareillage permet de deceler: moins de 10{sup -7} {mu}C {sup 241}Am dans les activites {alpha} Pu plusieurs centaines de fois plus importantes. II - Le meme appareillage a ete utilise pour des mesures {alpha} sur des sources emettrices {alpha} en presence d'activites {beta} et {gamma} tres importantes. En particulier des mesures d'activite {alpha} sur des echantillons de poudre sont exposees. Il est meme possible, dans ces conditions, de deceler ou mesurer {sup 241}Am. III - L'ensemble permet egalement: - l'etalonnage absolu d'une source de {sup 241}Am pur - des mesures de {sup 237}Np - des mesures simultanees d'activites {alpha}, {beta} et {gamma} dans des echantillons solides

  10. Rapid detection of AAC(6')-Ib-cr production using a MALDI-TOF MS strategy.

    Science.gov (United States)

    Pardo, C-A; Tan, R N; Hennequin, C; Beyrouthy, R; Bonnet, R; Robin, F

    2016-12-01

    Plasmid-mediated quinolone resistance mechanisms have become increasingly prevalent among Enterobacteriaceae strains since the 1990s. Among these mechanisms, AAC(6')-Ib-cr is the most difficult to detect. Different detection methods have been developed, but they require expensive procedures such as Sanger sequencing, pyrosequencing, polymerase chain reaction (PCR) restriction, or the time-consuming phenotypic method of Wachino. In this study, we describe a simple matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) method which can be easily implemented in clinical laboratories that use the MALDI-TOF technique for bacterial identification. We tested 113 strains of Enterobacteriaceae, of which 64 harbored the aac(6')-Ib-cr gene. We compared two MALDI-TOF strategies, which differed by their norfloxacin concentration (0.03 vs. 0.5 g/L), and the method of Wachino with the PCR and sequencing strategy used as the reference. The MALDI-TOF strategy, performed with 0.03 g/L norfloxacin, and the method of Wachino yielded the same high performances (Se = 98 %, Sp = 100 %), but the turnaround time of the MALDI-TOF strategy was faster (<5 h), simpler, and inexpensive (<1 Euro). Our study shows that the MALDI-TOF strategy has the potential to become a major method for the detection of many different enzymatic resistance mechanisms.

  11. Rapid identification and typing of Yersinia pestis and other Yersinia species by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry.

    Science.gov (United States)

    Ayyadurai, Saravanan; Flaudrops, Christophe; Raoult, Didier; Drancourt, Michel

    2010-11-12

    Accurate identification is necessary to discriminate harmless environmental Yersinia species from the food-borne pathogens Yersinia enterocolitica and Yersinia pseudotuberculosis and from the group A bioterrorism plague agent Yersinia pestis. In order to circumvent the limitations of current phenotypic and PCR-based identification methods, we aimed to assess the usefulness of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) protein profiling for accurate and rapid identification of Yersinia species. As a first step, we built a database of 39 different Yersinia strains representing 12 different Yersinia species, including 13 Y. pestis isolates representative of the Antiqua, Medievalis and Orientalis biotypes. The organisms were deposited on the MALDI-TOF plate after appropriate ethanol-based inactivation, and a protein profile was obtained within 6 minutes for each of the Yersinia species. When compared with a 3,025-profile database, every Yersinia species yielded a unique protein profile and was unambiguously identified. In the second step of analysis, environmental and clinical isolates of Y. pestis (n = 2) and Y. enterocolitica (n = 11) were compared to the database and correctly identified. In particular, Y. pestis was unambiguously identified at the species level, and MALDI-TOF was able to successfully differentiate the three biotypes. These data indicate that MALDI-TOF can be used as a rapid and accurate first-line method for the identification of Yersinia isolates.

  12. MR angiography in the diagnosis of cerebral venous angiomas: 3D TOF versus phase contrast

    International Nuclear Information System (INIS)

    Choi, Hye Young; Kim, Myung Hyen; Park, Hyung Chun; Lee, Min Hee; Kim, Yoo Kyung; Lee, Sun Wha

    1995-01-01

    To seek adequate sequence of MR angiography (MRA) on developmental venous anomaly in the brain. We collected ten cases who demonstrated developmental venous anomaly on MR image. Eight patients among them, both 3D time-of-fight (TOF) with or without Gadolinium-DTPA enhancement and phase contrast(PC) were performed: TOF without enhancement in five. TOF with enhancement in six, and PC with 10 cm/sec in five, PC with 30 cm/sec in three, and PC with 5 cm/sec velocity encoding (VNEC) in two cases. On enhanced 3D TOF, both dilated collecting veins and medullary veins were well depicted in five of six cases, however, the signal intensity of the collecting and medullary veins are less than arteries. Dilated hyperintense collecting veins were well demonstrated on 3D PC with below the 10 cm/sec VNEC in all seven cases, but the medullary veins were poorly defined. Unenhanced 3D TOF MRA could not reveal any dilated collecting and medullary veins in all five cases. Enhanced 3D TOF could demonstrate the collecting and medullary veins of developmental venous anomaly, however, 3D PC with below the 10 cm/sec VNEC could show the dilated collecting and larger draining veins. We considered that combined enhanced 3D TOF MRA and PC with VENC 10 cm/sec can substitute for conventional angiogram in the diagnosis of developmental venous anomaly

  13. Banque d’instruments de mesure en recherche : Une innovation au service des membres chercheurs en sciences infirmières

    Directory of Open Access Journals (Sweden)

    Sylvie Le May

    2017-04-01

    Full Text Available Résumé : Introduction : Face aux difficultés que rencontrent ses enseignants et étudiants à retrouver des instruments de mesure valides dans les bases de données, le Réseau de Recherche en Interventions en Sciences Infirmières du Québec (RRISIQ a récemment choisi de développer une banque d’instruments de mesure accessible et bien documentée utilisant le logiciel bibliographique Zotero. Cet article a pour but de décrire la Banque d’instruments du RRISIQ, d’en exposer les défis et ses perspectives de développement. Description : La Banque comprend plus de 1400 liens ou références à des instruments de mesure reliés aux interventions cliniques, à l’organisation des services infirmiers et à la formation infirmière. L’utilisateur a accès à des références bibliographiques d’articles scientifiques sur les instruments, en anglais et en français. En naviguant dans la Banque, il clique sur l'article de son choix, obtenant ainsi une description bibliographique complète, dont une adresse web lui permettant d’accéder en ligne au plein texte. Résultats : La Banque d’instruments Zotero nécessite un faible coût d’entretien technique pour effectuer des sauvegardes, résoudre les difficultés et gérer les demandes d'accès. Elle est appréciée par ses utilisateurs. Discussion : La Banque prendra de l’ampleur dans les années à venir et des démarches sont actuellement réalisées par l’équipe pour la publiciser davantage auprès de ses membres et de leurs étudiants. L’équipe envisage de la rendre disponible à d’autres équipes de recherche du Québec.

  14. N-glycosylation of Colorectal Cancer Tissues

    Science.gov (United States)

    Balog, Crina I. A.; Stavenhagen, Kathrin; Fung, Wesley L. J.; Koeleman, Carolien A.; McDonnell, Liam A.; Verhoeven, Aswin; Mesker, Wilma E.; Tollenaar, Rob A. E. M.; Deelder, André M.; Wuhrer, Manfred

    2012-01-01

    Colorectal cancer is the third most common cancer worldwide with an annual incidence of ∼1 million cases and an annual mortality rate of ∼655,000 individuals. There is an urgent need for identifying novel targets to develop more sensitive, reliable, and specific tests for early stage detection of colon cancer. Post-translational modifications are known to play an important role in cancer progression and immune surveillance of tumors. In the present study, we compared the N-glycan profiles from 13 colorectal cancer tumor tissues and corresponding control colon tissues. The N-glycans were enzymatically released, purified, and labeled with 2-aminobenzoic acid. Aliquots were profiled by hydrophilic interaction liquid chromatography (HILIC-HPLC) with fluorescence detection and by negative mode MALDI-TOF-MS. Using partial least squares discriminant analysis to investigate the N-glycosylation changes in colorectal cancer, an excellent separation and prediction ability were observed for both HILIC-HPLC and MALDI-TOF-MS data. For structure elucidation, information from positive mode ESI-ion trap-MS/MS and negative mode MALDI-TOF/TOF-MS was combined. Among the features with a high separation power, structures containing a bisecting GlcNAc were found to be decreased in the tumor, whereas sulfated glycans, paucimannosidic glycans, and glycans containing a sialylated Lewis type epitope were shown to be increased in tumor tissues. In addition, core-fucosylated high mannose N-glycans were detected in tumor samples. In conclusion, the combination of HILIC and MALDI-TOF-MS profiling of N-glycans with multivariate statistical analysis demonstrated its potential for identifying N-glycosylation changes in colorectal cancer tissues and provided new leads that might be used as candidate biomarkers. PMID:22573871

  15. Screening of 439 Pesticide Residues in Fruits and Vegetables by Gas Chromatography-Quadrupole-Time-of-Flight Mass Spectrometry Based on TOF Accurate Mass Database and Q-TOF Spectrum Library.

    Science.gov (United States)

    Li, Jian-Xun; Li, Xiao-Ying; Chang, Qiao-Ying; Li, Yan; Jin, Ling-He; Pang, Guo-Fang; Fan, Chun-Lin

    2018-05-03

    Because of its unique characteristics of accurate mass full-spectrum acquisition, high resolution, and fast acquisition rates, GC-quadrupole-time-of-flight MS (GC-Q-TOF/MS) has become a powerful tool for pesticide residue analysis. In this study, a TOF accurate mass database and Q-TOF spectrum library of 439 pesticides were established, and the parameters of the TOF database were optimized. Through solid-phase extraction (SPE), whereby pesticides are extracted from fruit and vegetable substrates by using 40 mL 1% acetic acid in acetonitrile (v/v), purified by the Carbon/NH₂ SPE cartridge, and finally detected by GC-Q-TOF/MS, the rapid analysis of 439 pesticides in fruits and vegetables can be achieved. The methodology verification results show that more than 70 and 91% of pesticides, spiked in fruits and vegetables with concentrations of 10 and 100 μg/kg, respectively, saw recoveries that conform to the European Commission's criterion of between 70 and 120% with RSD ≤20%. Eighty-one percent of pesticides have screening detection limits lower than 10 μg/kg, which makes this a reliable analysis technology for the monitoring of pesticide residues in fruits and vegetables. This technology was further validated for its characteristics of high precision, high speed, and high throughput through successful detection of 9817 samples during 2013-2015.

  16. Quantitative detection of RO2 radicals and other products from cyclohexene ozonolysis with ammonium-CI3-TOF and acetate-CI-API-TOF

    Science.gov (United States)

    Hansel, A.; Scholz, W.; Mentler, B.; Fischer, L.; Berndt, T.

    2017-12-01

    The performance of the novel ammonium-CI3-TOF utilizing NH4+ adduct ion chemistry to measure quantitatively first generation oxidized product molecules (OMs) as well as highly oxidized organic molecules (HOMs) was investigated for the first time. The gas-phase ozonolysis of cyclohexene served as a test system in order to evaluate the capability of the detection systems. Experiments have been carried out in the TROPOS free-jet flow system at close to atmospheric conditions. Product ion signals were simultaneously observed by the ammonium-CI3-TOF and the acetate-CI-API-TOF. Both instruments are in remarkable good agreement within a factor of two for HOMs. For OMs not containing an OOH group the acetate technique can considerably underestimate OM concentrations by 2-3 orders of magnitude. First steps of cyclohexene ozonolysis generate ten different (m/z product peaks) main products comprising 92% of observed OMs. The remaining 8% are distributed over several (m/z peaks) minor products that can be attributed to HOMs, predominately to highly oxidized RO2 radicals. Summing up, observed ammonium-CI3-TOF products yield 4.9 x 109 molecules cm-³ in excellent agreement with the amount of reacted cyclohexene of 5.0 x 109 molecules cm-³ for reactant concentrations of [O3] = 2.25 x 1012 molecules cm-³ and [cyclohexene] = 2.0 x 1012 molecules cm-³ and a reaction time of 7.9 s. NH4+ adduct ion chemistry based CIMS techniques offer a unique opportunity for complete detection of the whole product distribution, and consequently, for a much better understanding of atmospheric oxidation processes.

  17. Trees Outside Forests (TOF inventory as a tool for landscape analysis and support for territorial planning

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available During the FAO Expert Consultation on Global Forest Resources Assessment 2000 (Kotka - Finland 1996, the importance of Trees Outside Forests (TOF and the need for complete and detailed information about these stands were underlined for the first time. Since then and thanks to some pilot studies launched by FAO at the end of the ninenties, the international attention focused on three main topics: the definition of TOF and its classification (linear features, small woods, scattered and individual trees; the effective sampling methods to assess TOF, that are usually rare elements; the ecological role and the economic and social importance of TOF in industrialized and developing countries. Basing on these considerations, the sampling points of the second Italian National Forest Inventory (National Inventory of Forests and Carbon Sinks - INFC intercepting small woods or linear features were recorded. Consequently, the INFC provides information about a substantial portion of the TOF of the country. Thanks to the availability of these data, a specific study was undertaken, aimed at improving information on TOF features and their role in the landscape. The present paper reports on the first results of this study for four regions of the Central Italy (Lazio, Marche, Toscana and Umbria, where the TOF are particularly significant.

  18. New developments in molecular imaging: positron emission tomography time-of-flight (TOF-PET)

    International Nuclear Information System (INIS)

    Aguilar, P.; Couce, B.; Iglesias, A.; Lois, C.

    2011-01-01

    Positron Emission tomography (PET) in increasingly being used in oncology for the diagnosis and staging of disease, as well as in monitoring response to therapy. One of the last advances in PET is the incorporation of Time-of-Flight (TOF) information, which improves the tomographic reconstruction process and subsequently the quality of the final image. In this work, we explain the principles of PET and the fundamentals of TOF-PET. Clinical images are shown in order to illustrate how TOF-PET improves the detectability of small lesions, particularly in patients with high body mass index. (Author) 20 refs

  19. Wide-angle NSE and TOF the spectrometer SPAN at BENSC

    CERN Document Server

    Pappas, C; Kischnik, R; Mezei, F

    2002-01-01

    The cylindrical symmetry of the magnetic field configuration of SPAN allows for simultaneous neutron spin echo (NSE) measurements over the whole range of scattering angles accessible by a spectrometer. The open construction also allows for time-of-flight (TOF) measurements, which can be performed under the same conditions as NSE, in particular with polarization analysis. TOF and NSE spectra are then directly comparable with each other, without any adjustable parameters, covering a dynamic range of more than four orders of magnitude at a single wavelength. (orig.)

  20. Wide-angle NSE and TOF: the spectrometer SPAN at BENSC

    International Nuclear Information System (INIS)

    Pappas, C.; Triolo, A.; Kischnik, R.; Mezei, F.

    2002-01-01

    The cylindrical symmetry of the magnetic field configuration of SPAN allows for simultaneous neutron spin echo (NSE) measurements over the whole range of scattering angles accessible by a spectrometer. The open construction also allows for time-of-flight (TOF) measurements, which can be performed under the same conditions as NSE, in particular with polarization analysis. TOF and NSE spectra are then directly comparable with each other, without any adjustable parameters, covering a dynamic range of more than four orders of magnitude at a single wavelength. (orig.)

  1. Identification of clinically relevant Corynebacterium strains by Api Coryne, MALDI-TOF-mass spectrometry and molecular approaches.

    Science.gov (United States)

    Alibi, S; Ferjani, A; Gaillot, O; Marzouk, M; Courcol, R; Boukadida, J

    2015-09-01

    We evaluated the Bruker Biotyper matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) for the identification of 97 Corynebacterium clinical in comparison to identification strains by Api Coryne and MALDI-TOF-MS using 16S rRNA gene and hypervariable region of rpoB genes sequencing as a reference method. C. striatum was the predominant species isolated followed by C. amycolatum. There was an agreement between Api Coryne strips and MALDI-TOF-MS identification in 88.65% of cases. MALDI-TOF-MS was unable to differentiate C. aurimucosum from C. minutissimum and C. minutissimum from C. singulare but reliably identify 92 of 97 (94.84%) strains. Two strains remained incompletely identified to the species level by MALDI-TOF-MS and molecular approaches. They belonged to Cellulomonas and Pseudoclavibacter genus. In conclusion, MALDI-TOF-MS is a rapid and reliable method for the identification of Corynebacterium species. However, some limits have been noted and have to be resolved by the application of molecular methods. Copyright © 2015. Published by Elsevier SAS.

  2. Detection of Rickettsia spp in Ticks by MALDI-TOF MS

    Science.gov (United States)

    Yssouf, Amina; Almeras, Lionel; Terras, Jérôme; Socolovschi, Cristina; Raoult, Didier; Parola, Philippe

    2015-01-01

    Background Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) has been shown to be an effective tool for the rapid identification of arthropods, including tick vectors of human diseases. Methodology/Principal Findings The objective of the present study was to evaluate the use of MALDI-TOF MS to identify tick species, and to determine the presence of rickettsia pathogens in the infected Ticks. Rhipicephalus sanguineus and Dermacentor marginatus Ticks infected or not by R. conorii conorii or R. slovaca, respectively, were used as experimental models. The MS profiles generated from protein extracts prepared from tick legs exhibited mass peaks that distinguished the infected and uninfected Ticks, and successfully discriminated the Rickettsia spp. A blind test was performed using Ticks that were laboratory-reared, collected in the field or removed from patients and infected or not by Rickettsia spp. A query against our in-lab arthropod MS reference database revealed that the species and infection status of all Ticks were correctly identified at the species and infection status levels. Conclusions/Significance Taken together, the present work demonstrates the utility of MALDI-TOF MS for a dual identification of tick species and intracellular bacteria. Therefore, MALDI-TOF MS is a relevant tool for the accurate detection of Rickettsia spp in Ticks for both field monitoring and entomological diagnosis. The present work offers new perspectives for the monitoring of other vector borne diseases that present public health concerns. PMID:25659152

  3. Mesure asymétrie avant-arriere des quarks lourds a LEP1 avec le détecteur OPAL

    CERN Document Server

    Lafoux, H

    A partir de l'ensemble des données accumulées par OPAL au cours de la première phase de fonctionnement du LEP, nous avons mesuré l'asymétrie avant-arrière des quarks b et c au voisinage du pic du Zo. Utilisant une méthode traditionnelle, basée sur la détection des leptons produits dans les désintégrations semi-leptoniques des hadrons lourds, nous avons cherché à optimiser chaque étape de la mesure, en mettant en œuvre les algorithmes les plus appropriés. Le recours aux réseaux de neurones artificiels s'est en particulier avéré d'une grande utilité lorsque le problème à résoudre impliquait la prise en compte simultanée de multiples sources d'informations, d'origine et de nature très variées. Nos résultats sont en bon accord avec ceux des autres mesures effectuées à LEP et compatibles avec les prédictions du Modèle Standard pour un quark top de 174 ± 31 GeV/c2 et un boson de Higgs de masse comprise entre 60 et 1000 GeV/c2

  4. Mesure de la Polarisation des Lambda Produits dans les Collisions Positron-Electron AU Lep a L'aide du Detecteur Opal

    Science.gov (United States)

    Vandenplas, Denis

    Le Modele Standard est le cadre theorique general qui, jusqu'a present, a permis l'interpretation de tous les resultats experimentaux en physique des hautes energies. Cette theorie decrit, entre autres, la production d'une paire de particules elementaires, formee d'un quark et d'un antiquark, a partir de la desintegration de l'un des bosons mediateurs de l'interaction faible, le Z^0. Cependant, dans ce cas precis, la transformation subsequente des quarks primaires en particules reelles, un processus appele hadronisation, n'est decrite qu'a l'aide de modeles phenomenologiques. Afin de sonder les mecanismes de l'hadronisation, cette these presente la mesure du transfert du spin d'un quark etrange primaire a une particule appelee Lambda lors des desintegrations hadroniques du Z^0. L'etude a ete realisee dans le cadre de la collaboration OPAL, une des quatre experiences menees au collisionneur LEP, la ou des electrons et des positrons sont acceleres jusqu'a une energie commune, sqrt{s} = {rm E_ {cm}}, voisine de l'energie de production du rm Z^0, M_{Z ^0} egale a 91.3 GeV. La theorie electrofaible precise la direction du spin, c'est-a-dire la polarisation, d'un quark etrange primaire provenant de la desintegration d'un Z ^0. Quant a lui, le modele des quarks etablit que l'orientation du spin d'un Lambda est directement reliee a la polarisation du quark etrange dont il provient. La question est de determiner dans quelle mesure la polarisation du quark primaire est transmise au Lambda a la suite du processus de l'hadronisation, decrit dans le cadre de la ChromoDynamique Quantique. Une estimation, qui tient compte de tous ces differents aspects theoriques, evalue a 30% la polarisation des Lambda dont l'impulsion est superieure a 15 GeV/c. La mesure experimentale de la polarisation repose sur l'identification des Lambda a partir de la reconstitution de la desintegration Lambdato ppi^-. Ce processus, qui se deroule par le biais de l'interaction faible, viole la parite car

  5. Cocoa content influences chocolate molecular profile investigated by MALDI-TOF mass spectrometry.

    Science.gov (United States)

    Bonatto, Cínthia C; Silva, Luciano P

    2015-06-01

    Chocolate authentication is a key aspect of quality control and safety. Matrix-assisted laser desorption ionization time-of flight (MALDI-TOF) mass spectrometry (MS) has been demonstrated to be useful for molecular profiling of cells, tissues, and even food. The present study evaluated if MALDI-TOF MS analysis on low molecular mass profile may classify chocolate samples according to the cocoa content. The molecular profiles of seven processed commercial chocolate samples were compared by using MALDI-TOF MS. Some ions detected exclusively in chocolate samples corresponded to the metabolites of cocoa or other constituents. This method showed the presence of three distinct clusters according to confectionery and sensorial features of the chocolates and was used to establish a mass spectra database. Also, novel chocolate samples were evaluated in order to check the validity of the method and to challenge the database created with the mass spectra of the primary samples. Thus, the method was shown to be reliable for clustering unknown samples into the main chocolate categories. Simple sample preparation of the MALDI-TOF MS approach described will allow the surveillance and monitoring of constituents during the molecular profiling of chocolates. © 2014 Society of Chemical Industry.

  6. The role of vacuum in the quality of TOF mass spectrometer

    International Nuclear Information System (INIS)

    Bhowmick, A.; Gadkari, S.C.; Yakhmi, J.V.; Sahni, V.C.

    2005-01-01

    The art in the designing of time-of-flight mass spectrometers has come across a long course of development. The present day state-of-the-art machines are essentially the outcome of knowledge from the advances in different other areas of technology. This article discusses exclusively the role of UHV to enhance the quality of the TOF mass spectrometers and its application to the recently developed high resolution TOF mass spectrometer at TP and PED-BARC. (author)

  7. The Proton Beams for the New Time-of-Flight Neutron Facility at the CERN-PS

    CERN Document Server

    Cappi, R; Métral, G

    2000-01-01

    The experimental determination of neutron cross sections in fission and capture reactions as a function of the neutron energy is of primary importance in nuclear physics. Recent developments at CERN and elsewhere have shown that many fields of research and development, such as the design of Accelerator-Driven Systems (ADS) for nuclear waste incineration, nuclear astrophysics, fundamental nuclear physics, dosimetry for radiological protection and therapy, would benefit from a better knowledge of neutron cross sections. A neutron facility at the CERN-PS has been proposed with the aim of carrying out a systematic and high resolution study of neutron cross sections through Time-Of-Flight (n-TOF) measurement. The facility requires a high intensity proton beam (about 0.7x1013 particles/bunch) distributed in a short bunch (about 25 ns total length) to produce the neutrons by means of a spallation process in a lead target. To achieve these characteristics, a number of complex beam gymnastics have to be performed. All...

  8. Applications of TOF neutron diffraction in archaeometry

    Energy Technology Data Exchange (ETDEWEB)

    Kockelmann, W. [Rutherford Appleton Laboratory, ISIS Facility, Chilton (United Kingdom); Siano, S.; Bartoli, L. [Istituto di Fisica Applicata - CNR, Sesto Fiorentino (Italy); Visser, D. [Rutherford Appleton Laboratory, ISIS Facility, Chilton (United Kingdom); Netherlands Organisation for Scientific Research (NWO), Den Haag (Netherlands); Hallebeek, P. [Netherlands Institute for Cultural Heritage (ICN), Amsterdam (Netherlands); Traum, R. [Kunsthistorisches Museum Wien, Muenzkabinett, Vienna (Austria); Linke, R.; Schreiner, M. [Akademie der Bildenden Kuenste, Institut fuer Wissenschaften und Technologien in der Kunst, Vienna (Austria); Kirfel, A. [Universitaet Bonn, Mineralogisch-Petrologisches Institut, Bonn (Germany)

    2006-05-15

    Neutron radiation meets the demand for a versatile diagnostic probe for collecting information from the interior of large, undisturbed museum objects or archaeological findings. Neutrons penetrate through coatings and corrosion layers deep into centimetre-thick materials, a property that makes them ideal for non-destructive examination of objects for which sampling is impractical or unacceptable. A particular attraction of neutron techniques for archaeologists and conservation scientists is the prospect of locating hidden materials and structures inside objects. Time-of-flight (TOF) neutron diffraction allows for the examination of mineral and metal phase contents, crystal structures, grain orientations, and microstructures as well as micro- and macro strains. A promising application is texture analysis which may provide clues to the deformation history of the material, and hence to specific working processes. Here we report on instructive examples of TOF neutron diffraction, including phase analyses of medieval Dutch tin-lead spoons, texture analyses of bronze specimens as well as of 16th-century silver coins. (orig.)

  9. The Effect of Susceptibility Artifacts Related to Metallic Implants on Adjacent-Lesion Assessment in Simultaneous TOF PET/MR.

    Science.gov (United States)

    Svirydenka, Hanna; Delso, Gaspar; De Galiza Barbosa, Felipe; Huellner, Martin; Davison, Helen; Fanti, Stefano; Veit-Haibach, Patrick; Ter Voert, Edwin E G W

    2017-07-01

    Metalic implants may affect attenuation correction (AC) in PET/MR imaging. The purpose of this study was to evaluate the effect of susceptibility artifacts related to metallic implants on adjacent metabolically active lesions in clinical simultaneous PET/MR scanning for both time-of-flight (TOF) and non-TOF reconstructed PET images. Methods: We included 27 patients without implants but with confirmed 18 F-FDG-avid lesions adjacent to common implant locations. In all patients, a clinically indicated whole-body 18 F-FDG PET/MR scan was acquired. Baseline non-TOF and TOF PET images were reconstructed. Reconstruction was repeated after the introduction of artificial signal voids in the AC map to simulate metallic implants in standard anatomic areas. All reconstructed images were qualitatively and quantitatively assessed and compared with the baseline images. Results: In total, 51 lesions were assessed. In 40 and 50 of these cases (non-TOF and TOF, respectively), the detectability of the lesions did not change; in 9 and 1 cases, the detectability changed; and in 2 non-TOF cases, the lesions were no longer visible after the introduction of metallic artifacts. The inclusion of TOF information significantly reduced artifacts due to simulated implants in the femoral head, sternum, and spine ( P = 0.01, 0.01, and 0.03, respectively). It also improved image quality in these locations ( P = 0.02, 0.01, and 0.01, respectively). The mean percentage error was -3.5% for TOF and -4.8% for non-TOF reconstructions, meaning that the inclusion of TOF information reduced the percentage error in SUV max by 28.5% ( P metallic implants have a significant effect on small, moderately 18 F-FDG-avid lesions near the implant site that possibly may go unnoticed without TOF information. On larger, highly 18 F-FDG-avid lesions, the metallic implants had only a limited effect. The largest significant quantitative difference was found in artifacts of the sternum. There was only a weak inverse

  10. MALDI-TOF mass spectrometry in the clinical mycology laboratory: identification of fungi and beyond.

    Science.gov (United States)

    Posteraro, Brunella; De Carolis, Elena; Vella, Antonietta; Sanguinetti, Maurizio

    2013-04-01

    MALDI-TOF mass spectrometry (MS) is becoming essential in most clinical microbiology laboratories throughout the world. Its successful use is mainly attributable to the low operational costs, the universality and flexibility of detection, as well as the specificity and speed of analysis. Based on characteristic protein spectra obtained from intact cells - by means of simple, rapid and reproducible preanalytical and analytical protocols - MALDI-TOF MS allows a highly discriminatory identification of yeasts and filamentous fungi starting from colonies. Whenever used early, direct identification of yeasts from positive blood cultures has the potential to greatly shorten turnaround times and to improve laboratory diagnosis of fungemia. More recently, but still at an infancy stage, MALDI-TOF MS is used to perform strain typing and to determine antifungal drug susceptibility. In this article, the authors discuss how the MALDI-TOF MS technology is destined to become a powerful tool for routine mycological diagnostics.

  11. Mesures en matière de taxation des produits du tabac en Afrique de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Mesures en matière de taxation des produits du tabac en Afrique de l'Ouest. En décembre 2007, le programme Recherche pour la lutte mondiale contre le tabac (RMCT) a entrepris une initiative afin de comprendre les facteurs cruciaux qui peuvent déterminer le succès de la lutte antitabac en Afrique subsaharienne.

  12. Field Investigation Plan for 1301-N and 1325-N Facilities Sampling to Support Remedial Design

    International Nuclear Information System (INIS)

    Weiss, S. G.

    1998-01-01

    This field investigation plan (FIP) provides for the sampling and analysis activities supporting the remedial design planning for the planned removal action for the 1301-N and 1325-N Liquid Waste Disposal Facilities (LWDFs), which are treatment, storage,and disposal (TSD) units (cribs/trenches). The planned removal action involves excavation, transportation, and disposal of contaminated material at the Environmental Restoration Disposal Facility (ERDF).An engineering study (BHI 1997) was performed to develop and evaluate various options that are predominantly influenced by the volume of high- and low-activity contaminated soil requiring removal. The study recommended that additional sampling be performed to supplement historical data for use in the remedial design

  13. A solution for the inner area of CBM-TOF with pad-MRPC

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Y. [Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Huang, X.J., E-mail: huangxj12@mails.tsinghua.edu.cn [Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Lyu, P.F.; Han, D.; Xie, B.; Li, Y.J. [Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Herrmann, N.; Deppner, I.; Loizeau, P.; Simon, C. [Physikalisches Institute, University Heidelberg, Heidelberg (Germany); Frühauf, J.; Kiš, M. [GSI Helmholtzzentrum fr Schwerionenforschung, GSI, Damstadt (Germany)

    2017-02-11

    The Compressed Baryonic Matter (CBM) experiment has decided to use the Multi-gap Resistive Plate Chambers(MRPC) technology to build its Time-Of-Flight (TOF) wall. CBM-TOF requires a rate capability over 20 kHz/cm{sup 2} for inner region. A 10-gap pad-MRPC assembled with low resistive glass is designed to construct this area. The prototypes, which consist of 10×0.22 mm gas gaps and 2×8 20 mm×20 mm readout pads, require fewer electronic channels compared to the strip design. A timing resolution of around 60 ps and an efficiency above 98% were obtained in a cosmic test and a beam test taken in 2014 October GSI beam time. The results show that the real-size prototypes fulfill the requirements of the CBM-TOF.

  14. The protection of labour against radioactivity in French uranium mines; Mesures prises dans les mines d'uranium de France pour assurer la protection du personnel contre les dangers de la radioactivite

    Energy Technology Data Exchange (ETDEWEB)

    Avril, R; Berger, Ch; Duhamel, F; Pradel, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The exploration and working of radioactive mineral deposits expose those concerned to both external and internal irradiation. Special protective measures are therefore required. In French mines, systematic monitoring and the observation of safety rules are applied effectively in combating irradiation risk. The preventive measures, however, considerably affect the manner of working and consequently boost the cost of the ore. (author) [French] Les travaux de recherches et d'exploitation executes dans les gisements de substances radioactives exposent le personnel des irradiations internes et externes necessitant des mesures speciales de protection. Dans les mines fran ises, un controle systematique des conditions de travail permet de mener de fa n efficace la lutte contre ces irradiations en respectant certaines normes de securite. Les mesures de prevention ont des repercussions sensibles sur la conduite de l'exploitation et, par suite, sur le prix de revient du minerai extrait. (auteur)

  15. Enhanced MALDI-TOF MS Analysis of Phosphopeptides Using an Optimized DHAP/DAHC Matrix

    Science.gov (United States)

    Hou, Junjie; Xie, Zhensheng; Xue, Peng; Cui, Ziyou; Chen, Xiulan; Li, Jing; Cai, Tanxi; Wu, Peng; Yang, Fuquan

    2010-01-01

    Selecting an appropriate matrix solution is one of the most effective means of increasing the ionization efficiency of phosphopeptides in matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In this study, we systematically assessed matrix combinations of 2, 6-dihydroxyacetophenone (DHAP) and diammonium hydrogen citrate (DAHC), and demonstrated that the low ratio DHAP/DAHC matrix was more effective in enhancing the ionization of phosphopeptides. Low femtomole level of phosphopeptides from the tryptic digests of α-casein and β-casein was readily detected by MALDI-TOF-MS in both positive and negative ion mode without desalination or phosphopeptide enrichment. Compared with the DHB/PA matrix, the optimized DHAP/DAHC matrix yielded superior sample homogeneity and higher phosphopeptide measurement sensitivity, particularly when multiple phosphorylated peptides were assessed. Finally, the DHAP/DAHC matrix was applied to identify phosphorylation sites from α-casein and β-casein and to characterize two phosphorylation sites from the human histone H1 treated with Cyclin-Dependent Kinase-1 (CDK1) by MALDI-TOF/TOF MS. PMID:20339515

  16. Enhanced MALDI-TOF MS Analysis of Phosphopeptides Using an Optimized DHAP/DAHC Matrix

    Directory of Open Access Journals (Sweden)

    Junjie Hou

    2010-01-01

    Full Text Available Selecting an appropriate matrix solution is one of the most effective means of increasing the ionization efficiency of phosphopeptides in matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS. In this study, we systematically assessed matrix combinations of 2, 6-dihydroxyacetophenone (DHAP and diammonium hydrogen citrate (DAHC, and demonstrated that the low ratio DHAP/DAHC matrix was more effective in enhancing the ionization of phosphopeptides. Low femtomole level of phosphopeptides from the tryptic digests of α-casein and β-casein was readily detected by MALDI-TOF-MS in both positive and negative ion mode without desalination or phosphopeptide enrichment. Compared with the DHB/PA matrix, the optimized DHAP/DAHC matrix yielded superior sample homogeneity and higher phosphopeptide measurement sensitivity, particularly when multiple phosphorylated peptides were assessed. Finally, the DHAP/DAHC matrix was applied to identify phosphorylation sites from α-casein and β-casein and to characterize two phosphorylation sites from the human histone H1 treated with Cyclin-Dependent Kinase-1 (CDK1 by MALDI-TOF/TOF MS.

  17. Lifetime measurement in Proserpine by reactivity modulation (1960); Mesure du temps de vie dans proserpine par modulation de la reactivite (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Clouet d' Orval, C; Tachon, J; Bertrand, J; Lecoustey, P [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The measurement method consists in varying the neutron flux periodically by means of an oscillator with cadmium sectors. From the signal received on a detector the lifetime {tau} can be determined; for various velocities {omega}, we have: (n/{delta}n){sup 2} = ({beta}{sub eff}/{delta}k){sup 2} + ({tau}/{delta}k){sup 2}{omega}{sup 2}. Various corrections are involved, in particular the calculation of the rates of different harmonics in the oscillator signal. (author) [French] La methode de mesure consiste a faire varier periodiquement le flux de neutrons au moyen d'un oscillateur a secteurs de cadmium. Le signal recu sur un detecteur permet la determination du temps de vie {tau}; pour differentes vitesses {omega}, on a: (n/{delta}n){sup 2} = ({beta}{sub eff}/{delta}k){sup 2} + ({tau}/{delta}k){sup 2}{omega}{sup 2}. Differentes corrections interviennent, en particulier, le calcul du taux des differents harmoniques dans le signal de l'oscillateur. (auteur)

  18. TOF-SIMS studies of yttria-stabilised zirconia

    DEFF Research Database (Denmark)

    Hansen, Karin Vels; Norrman, Kion; Mogensen, Mogens Bjerg

    2006-01-01

    The surface of an as-polished and an as-sintered yttria-stabilised zirconia pellet was analysed with XPS and TOF-SIMS (depth profiling and imaging) in order to study the distribution of impurities. The polished sample was slightly contaminated with Na, K, Mg and Ca. The sintered sample showed...

  19. Measurement of radioactive isotopes by {gamma} and x rays spectrometry with INa crystals. application to radiochemistry of some fission and activation products; Mesures d'isotopes radioactifs par spectrometrie {gamma} et x a l'aide de cristaux INa. application a la radiochimie de certains produits de fission et d'activation

    Energy Technology Data Exchange (ETDEWEB)

    Simonet, P; Boile, G; Simonet, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    The measurement of an number of atoms N may be obtained by detection of one {gamma} ray emitted if its branching ratio K{sub E} is known (number of E energy {gamma} transitions/number of disintegrations). N = A/{lambda} N{sub {gamma}}{sub E} / (K{sub E} * {lambda}) This measurement is effectuated in well-defined geometry, {gamma} rays emitted by the source are detected by a calibrated NaI crystal which is connected to a photomultiplier delivering electric impulses analysed by a multichannel analyser. Crystals are chosen according to energy, intensity of measured rays and of background. Calibration is established with standard sources or by total absolute efficiency of a definite crystal. Half-life, energy of measured photopeak branching ratio have been determined for these isotopes: Fission products: {sup 95}Zr, {sup 95}Nb, {sup 99}Mo, {sup 103}Ru, {sup 106}Ru, {sup 111}Ag, {sup 115}Cd, {sup 115m}Cd, {sup 132}Te, {sup 129m}Te, {sup 134}Cs, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La. Rare earth elements: {sup 91}Y, {sup 141}Ce, {sup 144}Ce, {sup 147}Nd, {sup 156}Eu. Products from reactions (n, {gamma}) (n, 2n): 1{sup 10}Ag, {sup 124}Sb, {sup 239}Np, {sup 237}U, {sup 241}Am. (authors) [French] La mesure du nombre d'atomes N d'un isotope peut s'effectuer sur un rayonnement {gamma} si l'on connait le rapport d'embranchement K{sub E} (nombre de rayonnements {gamma} d'energie E/nombre de desintegrations). N = A/{lambda} N{sub {gamma}}{sub E} / (K{sub E} * {lambda}) La mesure s'effectue en geometrie definie; les rayonnements {gamma} emis par la source sous mylar sont detectes par un cristal INa etalonne en fonction de l'energie, lequel est relie a un photomultiplicateur delivrant des impulsions electriques qui seront analysees par un selecteur multicanaux. La connaissance de la distribution theorique (effet photoelectrique, compton, paires, retrodiffusion, echappement... ) permet de determiner qualitativement si les elements sont purs, et de faire une mesure sur

  20. Product ion distributions for the reactions of NO+ with some N-containing and O-containing heterocyclic compounds obtained using SRI-TOF-MS

    Czech Academy of Sciences Publication Activity Database

    Mochalski, P.; Unterkofler, K.; Španěl, Patrik; Smith, D.; Amann, A.

    2015-01-01

    Roč. 386, JUL 2015 (2015), s. 42-46 ISSN 1387-3806 Institutional support: RVO:61388955 Keywords : heterocyclic compounds * SRI-TOF-MS * NO+ reactions Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.183, year: 2015

  1. MALDI-TOF identification of Gram-negative bacteria directly from blood culture bottles containing charcoal: Sepsityper® kits versus centrifugation-filtration method.

    Science.gov (United States)

    Riederer, Kathleen; Cruz, Kristian; Shemes, Stephen; Szpunar, Susan; Fishbain, Joel T

    2015-06-01

    Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry has dramatically altered the way microbiology laboratories identify clinical isolates. Direct blood culture (BC) detection may be hampered, however, by the presence of charcoal in BC bottles currently in clinical use. This study evaluates an in-house process for extraction and MALDI-TOF identification of Gram-negative bacteria directly from BC bottles containing charcoal. Three hundred BC aliquots were extracted by a centrifugation-filtration method developed in our research laboratory with the first 96 samples processed in parallel using Sepsityper® kits. Controls were colonies from solid media with standard phenotypic and MALDI-TOF identification. The identification of Gram-negative bacteria was successful more often via the in-house method compared to Sepsityper® kits (94.7% versus 78.1%, P≤0.0001). Our in-house centrifugation-filtration method was further validated for isolation and identification of Gram-negative bacteria (95%; n=300) directly from BC bottles containing charcoal. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Bacterial flora analysis of coliforms in sewage, river water, and ground water using MALDI-TOF mass spectrometry.

    Science.gov (United States)

    Suzuki, Yoshihiro; Niina, Kouki; Matsuwaki, Tomonori; Nukazawa, Kei; Iguchi, Atsushi

    2018-01-28

    The aim of this study was to rapidly and effectively analyze coliforms, which are the most fundamental indicators of water quality for fecal pollution, using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). Coliform bacteria were isolated from municipal sewage, river water, and groundwater. For each sample, 100 isolates were determined by MALDI-TOF MS. In addition, these same 100 isolates were also identified via 16S rRNA gene sequence analysis. Obtained MALDI-TOF MS data were compared with the 16S rRNA sequencing analysis, and the validity of MALDI-TOF MS for classification of coliform bacteria was examined. The concordance rate of bacterial identification for the 100 isolates obtained by MALDI-TOF MS analysis and 16S rRNA gene sequence analysis for sewage, river water, and ground water were 96%, 74%, and 62% at the genus level, respectively. Among the sewage, river water, and ground water samples, the coliform bacterial flora were distinct. The dominant genus of coliforms in sewage, river water, and groundwater were Klebsiella spp., Enterobacter spp., and Serratia spp., respectively. We determined that MALDI-TOF MS is a rapid and accurate tool that can be used to identify coliforms. Therefore, without using conventional 16S rRNA sequencing, it is possible to rapidly and effectively classify coliforms in water using MALDI-TOF MS.

  3. The n,{gamma} discrimination in recoil-proton proportional counters. Application to the measurement of fast neutron spectra; Discrimination n,{gamma} dans les compteurs proportionnels a protons de recul. Application a la mesure des spectres de neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Jeandidier, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A description is given of a spectrometry chain working in the energy range of a few keV to 1 MeV, and designed for measurement of fast neutron spectra. It consists of detectors, recoil proton proportional counters built especially for this work by R. COMTE (DEG/SER) and which make it possible to cover the energy range and also associated electronic equipment. A brief description is first given of the physical processes involved: (n,p) collisions in the gas, influence of {gamma} radiation; the method of discrimination is then presented. It is based on the difference in the rise-times of the pulses. In the experiments described here the use of a bi-parametric system made it possible to employ the most simple discrimination device, based on the fact that the high frequency gamma pulse components are, at a given energy, weaker than those of the neutron pulses. Results are given of measurements carried out on the Van der Graaff (mono-energetic neutrons for testing the linearity of the chain and the resolving power of the counters), and of those made in a sub-critical system Hug at Cadarache. (author) [French] On decrit une chaine de spectrometrie travaillant dans le domaine d'energie de quelques keV a 1 MeV destinee a la mesure des spectres de neutrons rapides. Elle comprend les detecteurs, compteurs proportionnels a protons de recul, realises specialement pour cette etude par M. R. COMTE (DEG/SER), permettant de couvrir la gamme d'energie et l'electronique associee. Apres un rappel des processus physiques mis en jeu: chocs (n,p) dans les gaz, influence des rayonnements {gamma}, on expose la methode de discrimination utilisee. Celle-ci est basee sur la difference des temps de montee des impulsions. Au cours des experiences rapportees ici, la mise en oeuvre d'un ensemble bi-parametrique a permis d'utiliser le dispositif de discrimination le plus simple, base sur la remarque que les composantes a haute frequence des impulsions {gamma} sont, a energie egale, plus faibles

  4. The n,{gamma} discrimination in recoil-proton proportional counters. Application to the measurement of fast neutron spectra; Discrimination n,{gamma} dans les compteurs proportionnels a protons de recul. Application a la mesure des spectres de neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Jeandidier, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    A description is given of a spectrometry chain working in the energy range of a few keV to 1 MeV, and designed for measurement of fast neutron spectra. It consists of detectors, recoil proton proportional counters built especially for this work by R. COMTE (DEG/SER) and which make it possible to cover the energy range and also associated electronic equipment. A brief description is first given of the physical processes involved: (n,p) collisions in the gas, influence of {gamma} radiation; the method of discrimination is then presented. It is based on the difference in the rise-times of the pulses. In the experiments described here the use of a bi-parametric system made it possible to employ the most simple discrimination device, based on the fact that the high frequency gamma pulse components are, at a given energy, weaker than those of the neutron pulses. Results are given of measurements carried out on the Van der Graaff (mono-energetic neutrons for testing the linearity of the chain and the resolving power of the counters), and of those made in a sub-critical system Hug at Cadarache. (author) [French] On decrit une chaine de spectrometrie travaillant dans le domaine d'energie de quelques keV a 1 MeV destinee a la mesure des spectres de neutrons rapides. Elle comprend les detecteurs, compteurs proportionnels a protons de recul, realises specialement pour cette etude par M. R. COMTE (DEG/SER), permettant de couvrir la gamme d'energie et l'electronique associee. Apres un rappel des processus physiques mis en jeu: chocs (n,p) dans les gaz, influence des rayonnements {gamma}, on expose la methode de discrimination utilisee. Celle-ci est basee sur la difference des temps de montee des impulsions. Au cours des experiences rapportees ici, la mise en oeuvre d'un ensemble bi-parametrique a permis d'utiliser le dispositif de discrimination le plus simple, base sur la remarque que les composantes a haute frequence des impulsions {gamma} sont, a

  5. Continuous measurement of neutron flux with the help of a converter; Mesure continue des flux de neutrons a l'aide d'un dispositif convertisseur

    Energy Technology Data Exchange (ETDEWEB)

    Mas, P; Sciers, P [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1964-07-01

    The device described in this report is working from this following principle: an element, the thermal neutron activate of which has a short period and is emitter of a {beta} particle, is surrounded with a dielectric which is itself surrounded by a conducting metal. {beta} particles are stopped in the conducting metal. Thus an electric current rises between the emitter element and the collector metal. The experimental study has been-done with rhodium as emitter. The linearity as function of thermal flux of the power of the pile, the accuracy, the efficiency of the device have been measured and are satisfactory. Just the stability of the measure equipment is not very good. This method gives, us at moment the instantaneous flux and the integrated flux, is well adapted for the measurements in pile to execute on loops. It is possible to continue to perfect the process. (authors) [French] Le dispositif decrit dans ce rapport fonctionne d'apres le principe suivant: un corps, dont le produit d'activation en neutrons thermiques a une courte periode et est emetteur d'une particule {beta}, est entoure d'un dielectrique lui-meme entoure d'un metal conducteur. Les particules {beta} sont arretees dans le metal conducteur. Il y a ainsi naissance d'un courant electrique entre le corps emetteur et le metal collecteur. L'etude experimentale a ete menee avec le rhodium comme emetteur. La linearite en fonction du flux thermique, de la puissance de la pile, la precision, le rendement du dispositif ont ete mesures et sont satisfaisants. Seule la stabilite de l'appareillage de mesure n'est pas tres bonne. Cette methode, qui peut nous donner a tout instant le flux instantane et le flux integre, est tout a fait adaptee aux mesures en pile a effectuer. sur des boucles. On peut poursuivre la mise au point du procede. (auteurs)

  6. Engineering Evaluation/Cost Analysis for the 100-N Area Ancillary Facilities and Integration Plan

    International Nuclear Information System (INIS)

    Mukherjee, B.

    1997-09-01

    This document presents the results of an engineering evaluation/cost analysis (EE/CA) that was conducted to evaluate alternatives for addressing final disposition of contaminated buildings and structures in the 100-N Area of the Hanford Site. The Hanford Site is located in southeastern Washington State and is owned by the U.S. Government and operated by the U.S. Department of Energy, Richland Operations Office (RL). In November 1989, the 100 Area of the Hanford Site (as well as the 200, 300, and 1100 Areas) was placed on the U.S. Environmental Protection Agency's National Priorities List (NPL) under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980. The 100 Area NPL includes the 100-N Area, which is in various stages of the remediation process. It has been determined by RL that hazardous substances in the 100-N Area ancillary facilities may present a potential threat to human health or the environment, and that a non-time critical removal action at these facilities is warranted. To help determine the most appropriate action, RL, in cooperation with the Washington State Department of Ecology (Ecology) and the EPA, has prepared this EE/CA. The scope of the evaluation includes the inactive contaminated ancillary facilities in the 100-N Area, the facilities residing in the buffer zone, and the Hanford Generating Plant (HGP) and the solid waste management units (SWMUs) inside HGP support facilities. The 105-N Reactor and 109-N Heat Exchange facilities are excluded from this EE/CA evaluation

  7. MALDI-TOF typing highlights geographical and fluconazole resistance clusters in Candida glabrata.

    Science.gov (United States)

    Dhieb, C; Normand, A C; Al-Yasiri, M; Chaker, E; El Euch, D; Vranckx, K; Hendrickx, M; Sadfi, N; Piarroux, R; Ranque, S

    2015-06-01

    Utilizing matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectra for Candida glabrata typing would be a cost-effective and easy-to-use alternative to classical DNA-based typing methods. This study aimed to use MALDI-TOF for the typing of C. glabrata clinical isolates from various geographical origins and test its capacity to differentiate between fluconazole-sensitive and -resistant strains.Both microsatellite length polymorphism (MLP) and MALDI-TOF mass spectra of 58 C. glabrata isolates originating from Marseilles (France) and Tunis (Tunisia) as well as collection strains from diverse geographic origins were analyzed. The same analysis was conducted on a subset of C. glabrata isolates that were either susceptible (MIC ≤ 8 mg/l) or resistant (MIC ≥ 64 mg/l) to fluconazole.According to the seminal results, both MALDI-TOF and MLP classifications could highlight C. glabrata population structures associated with either geographical dispersal barriers (p typing to investigate C. glabrata infection outbreaks and predict the antifungal susceptibility profile of clinical laboratory isolates. © The Author 2015. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Integrated quantitative and qualitative workflow for in vivo bioanalytical support in drug discovery using hybrid Q-TOF-MS.

    Science.gov (United States)

    Ranasinghe, Asoka; Ramanathan, Ragu; Jemal, Mohammed; D'Arienzo, Celia J; Humphreys, W Griffith; Olah, Timothy V

    2012-03-01

    UHPLC coupled with orthogonal acceleration hybrid quadrupole-TOF (Q-TOF)-MS is an emerging technique offering new strategies for the efficient screening of new chemical entities and related molecules at the early discovery stage within the pharmaceutical industry. In the first part of this article, we examine the main instrumental parameters that are critical for the integration of UHPLC-Q-TOF technology to existing bioanalytical workflows, in order to provide simultaneous quantitative and qualitative bioanalysis of samples generated following in vivo studies. Three modern Q-TOF mass spectrometers, including Bruker maXis™, Agilent 6540 and Sciex TripleTOF™ 5600, all interfaced with UHPLC systems, are evaluated in the second part of the article. The scope of this work is to demonstrate the potential of Q-TOF for the analysis of typical small molecules, therapeutic peptides (molecular weight <6000 Da), and enzymatically (i.e., trypsin, chymotrypsin and pepsin) cleaved peptides from larger proteins. This work focuses mainly on full-scan TOF data obtained under ESI conditions, the major mode of TOF operation in discovery bioanalytical research, where the compounds are selected based on their pharmacokinetic/pharmacodynamic behaviors using animal models prior to selecting a few desirable candidates for further development. Finally, important emerging TOF technologies that could potentially benefit bioanalytical research in the semi-quantification of metabolites without synthesized standards are discussed. Particularly, the utility of captive spray ionization coupled with TripleTOF 5600 was evaluated for improving sensitivity and providing normalized MS response for drugs and their metabolites. The workflow proposed compromises neither the efficiency, nor the quality of pharmacokinetic data in support of early drug discovery programs.

  9. Rapid and accurate identification of Streptococcus equi subspecies by MALDI-TOF MS

    DEFF Research Database (Denmark)

    Kudirkiene, Egle; Welker, Martin; Knudsen, Nanna Reumert

    2015-01-01

    phenotypic and sequence similarity between three subspecies their discrimination remains difficult. In this study, we aimed to design and validate a novel, Superspectra based, MALDI-TOF MS approach for reliable, rapid and cost-effective identification of SEE and SEZ, the most frequent S. equi subspecies.......3±7.5%). This result may be attributed to the highly clonal population structure of SEE, as opposed to the diversity of SEZ seen in horses. Importantly strains with atypical colony appearance both within SEE and SEZ did not affect correct identification of the strains by MALDI-TOF MS. Atypical colony variants...... are often associated with a higher persistence or virulence of S. equi, thus their correct identification using the current method strengthens its potential use in routine clinical diagnostics. In conclusion, reliable identification of S. equi subspecies was achieved by combining a MALDI-TOF MS method...

  10. Mesure de la vitesse d'infiltration des eaux dans le sol : Cas des sols ...

    African Journals Online (AJOL)

    C'est donc une infiltration superficielle qui ne peut pas modifier la composition des eaux de l'aquifère. Ces sols sont alors favorables à une telle agriculture. Mots clés: mesure, vitesse, infiltration, sols, pollutions, eau, Niari, Congo. English Title: Measuring the speed of the water infiltration into the soil: case of the soil of the ...

  11. CERN’s neutrons fly higher

    CERN Multimedia

    Antonella Del Rosso

    2012-01-01

    The construction of a second experimental area for n_TOF – CERN’s neutron source – has just been approved by the CERN Council. The new facility will provide the scientific community with a higher neutron flux, which translates into a higher sensitivity for the experiments. The new neutron beam line will open the way to a wider variety of research fields including nuclear energy applications, nuclear astrophysics, basic nuclear physics, dosimetry and radiation damage.   The 4π calorimeter inside the n_TOF experimental area. Image courtesy of the n_TOF Collaboration. The project involves building a vertical flight path roughly 20 m above the current neutron target and a new experimental hall – Experimental Area 2 (EAR-2) – in the current Building 559. EAR-2 will be located on top of the neutron production target and partially on top of the ISR building (see the image below of a model of the facility). “The hall will be housed i...

  12. Application of MALDI-TOF MS for requalification of a Candida clinical isolates culture collection

    Directory of Open Access Journals (Sweden)

    Reginaldo Lima-Neto

    2014-06-01

    Full Text Available Microbial culture collections underpin biotechnology applications and are important resources for clinical microbiology by supplying reference strains and/or performing microbial identifications as a service. Proteomic profiles by MALDI-TOF MS have been used for Candida spp. identification in clinical laboratories and demonstrated to be a fast and reliable technique for the routine identification of pathogenic yeasts. The main aim of this study was to apply MALDI-TOF MS combined with classical phenotypic and molecular approaches to identify Candida clinical isolates preserved from 1 up to 52 years in a Brazilian culture collection and assess its value for the identification of yeasts preserved in this type of collections. Forty Candida spp. clinical isolates were identified by morphological and biochemical analyses. Identifications were also performed by the new proteomic approach based on MALDI-TOF MS. Results demonstrated 15% discordance when compared with morphological and biochemical analyses. Discordant isolates were analysed by ITS sequencing, which confirmed the MALDI-TOF MS identifications and these strains were renamed in the culture collection catalogue. In conclusion, proteomic profiles by MALDI-TOF MS represents a rapid and reliable method for identifying clinical Candida species preserved in culture collections and may present clear benefits when compared with the performance of existing daily routine methods applied at health centres and hospitals.

  13. In-beam test of Neutron detector array facility at IUAC

    International Nuclear Information System (INIS)

    Sugathan, P.; Jhingan, A.; Saneesh, S.

    2014-01-01

    A new experimental facility dedicated for the study of fission dynamics has been installed and commissioned recently at Inter University Accelerator Centre (IUAC), New Delhi. The facility, National Array of Neutron Detectors (NAND) is used for the systematic studies on fission dynamics around Coulomb barrier energies using heavy ion beams from the Tandem plus LINAC accelerator facilities. The detector array consists 100 neutron detectors mounted on a geodesic dome structure at a radial distance of 175 cm from the target and multi wire proportional counters (MWPC) for detection of fission fragments. Each neutron detector is made of 5'' x 5'' cylindrical cell filled with BC501A organic liquid scintillator and coupled to a 5'' photo multiplier tube. A 100 cm diameter spherical vacuum chamber has been installed at the center of the array to house the targets, fission fragment detectors and other ancillary charged particle detectors. The vacuum chamber is made of 4mm thick steel and has target ladder with linear and rotary movements. The detector array is installed on a dedicated beam line of LINAC accelerator facilities at beam hall II. The neutrons are discriminated from gamma rays using pulse shape discrimination (PSD) technique based on conventional analog electronics and the energies of neutrons are measured by the time of flight (TOF) method. For this purpose, custom made electronics modules have been built to process signal from each detector. This module contains the integrated electronics for n - γ discrimination, time of flight (TOF) and light output. The fission fragments are detected in low pressure MWPCs mounted inside the spherical vacuum chamber. The MWPC has been built based on the conventional design using three electrodes, having a central cathode foil electrode sandwiched between two position sensing anode wire/strip frames. In order to acquire data from detector array, the data acquisition system has been implemented using VME based hardware systems

  14. Analytical detection of explosives and illicit, prescribed and designer drugs using proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Bishu; Petersson, Fredrik; Juerschik, Simone [Institut fuer Ionenphysik und Angewandte Physik, Universitaet Innsbruck, Technikerstr. 25, 6020 Innsbruck (Austria); Sulzer, Philipp; Jordan, Alfons [IONICON Analytik GmbH, Eduard-Bodem-Gasse 3, 6020 Innsbruck (Austria); Maerk, Tilmann D. [Institut fuer Ionenphysik und Angewandte Physik, Universitaet Innsbruck, Technikerstr. 25, 6020 Innsbruck (Austria); IONICON Analytik GmbH, Eduard-Bodem-Gasse 3, 6020 Innsbruck (Austria); Watts, Peter; Mayhew, Chris A. [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham B15 4TT (United Kingdom)

    2011-07-01

    This work demonstrates the extremely favorable features of Proton Transfer Reaction Time-of-flight Mass Spectrometry (PTR-TOF-MS) for the detection and identification of solid explosives, chemical warfare agent simulants and illicit, prescribed and designer drugs in real time. Here, we report the use of PTR-TOF, for the detection of explosives (e.g., trinitrotoluene, trinitrobenzene) and illicit, prescribed and designer drugs (e.g., ecstasy, morphine, heroin, ethcathinone, 2C-D). For all substances, the protonated parent ion (as we used H{sub 3}O{sup +} as a reagent ion) could be detected, providing a high level of confidence in their identification since the high mass resolution allows compounds having the same nominal mass to be separated. We varied the E/N from 90 to 220 T{sub d} (1 T{sub d}=10{sup -17} Vcm{sup -1}). This allowed us to study fragmentation pathways as a function of E/N (reduced electric field). For a few compounds rather unusual E/N dependencies were also discovered.

  15. Multi-dimensional TOF-SIMS analysis for effective profiling of disease-related ions from the tissue surface.

    Science.gov (United States)

    Park, Ji-Won; Jeong, Hyobin; Kang, Byeongsoo; Kim, Su Jin; Park, Sang Yoon; Kang, Sokbom; Kim, Hark Kyun; Choi, Joon Sig; Hwang, Daehee; Lee, Tae Geol

    2015-06-05

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) emerges as a promising tool to identify the ions (small molecules) indicative of disease states from the surface of patient tissues. In TOF-SIMS analysis, an enhanced ionization of surface molecules is critical to increase the number of detected ions. Several methods have been developed to enhance ionization capability. However, how these methods improve identification of disease-related ions has not been systematically explored. Here, we present a multi-dimensional SIMS (MD-SIMS) that combines conventional TOF-SIMS and metal-assisted SIMS (MetA-SIMS). Using this approach, we analyzed cancer and adjacent normal tissues first by TOF-SIMS and subsequently by MetA-SIMS. In total, TOF- and MetA-SIMS detected 632 and 959 ions, respectively. Among them, 426 were commonly detected by both methods, while 206 and 533 were detected uniquely by TOF- and MetA-SIMS, respectively. Of the 426 commonly detected ions, 250 increased in their intensities by MetA-SIMS, whereas 176 decreased. The integrated analysis of the ions detected by the two methods resulted in an increased number of discriminatory ions leading to an enhanced separation between cancer and normal tissues. Therefore, the results show that MD-SIMS can be a useful approach to provide a comprehensive list of discriminatory ions indicative of disease states.

  16. New methods of microbiological identification using MALDI-TOF

    Directory of Open Access Journals (Sweden)

    Jacyr Pasternak

    2012-03-01

    Full Text Available Rapid diagnosis of pathogens is decisive to guarantee adequatetherapy in infections: culture methods are precise and sensitive, butrather slow. New resources are available to enable faster diagnosis,and the most promising is MALDI-TOF technology: mass spectrometryapplied to microbiological diagnosis. Times as fast as 10 to 15 minutes to etiological diagnosis are possible after a positive blood culture result. We hope to have this technology in our laboratory, ANVISA permitting and improving their very slow rate of doing things… MALDI-TOF is basically putting a sample of culture or an enriched suspension of the probable pathogen over a small spot with a matrix and vaporizing it with a laser pulse: the products are aspired into a chamber, ionized and reach detectors at variable times: the detectors show time of arrival and quantity of the product, and each pathogen has its characteristic spectrum analyzed by a software.

  17. Reliable identification at the species level of Brucella isolates with MALDI-TOF-MS

    Directory of Open Access Journals (Sweden)

    Lista Florigio

    2011-12-01

    Full Text Available Abstract Background The genus Brucella contains highly infectious species that are classified as biological threat agents. The timely detection and identification of the microorganism involved is essential for an effective response not only to biological warfare attacks but also to natural outbreaks. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS is a rapid method for the analysis of biological samples. The advantages of this method, compared to conventional techniques, are rapidity, cost-effectiveness, accuracy and suitability for the high-throughput identification of bacteria. Discrepancies between taxonomy and genetic relatedness on the species and biovar level complicate the development of detection and identification assays. Results In this study, the accurate identification of Brucella species using MALDI-TOF-MS was achieved by constructing a Brucella reference library based on multilocus variable-number tandem repeat analysis (MLVA data. By comparing MS-spectra from Brucella species against a custom-made MALDI-TOF-MS reference library, MALDI-TOF-MS could be used as a rapid identification method for Brucella species. In this way, 99.3% of the 152 isolates tested were identified at the species level, and B. suis biovar 1 and 2 were identified at the level of their biovar. This result demonstrates that for Brucella, even minimal genomic differences between these serovars translate to specific proteomic differences. Conclusions MALDI-TOF-MS can be developed into a fast and reliable identification method for genetically highly related species when potential taxonomic and genetic inconsistencies are taken into consideration during the generation of the reference library.

  18. A multi-center ring trial for the identification of anaerobic bacteria using MALDI-TOF MS.

    Science.gov (United States)

    Veloo, A C M; Jean-Pierre, H; Justesen, U S; Morris, T; Urban, E; Wybo, I; Shah, H N; Friedrich, A W; Morris, T; Shah, H N; Jean-Pierre, H; Justesen, U S; Nagy, E; Urban, E; Kostrzewa, M; Veloo, A; Friedrich, A W

    2017-12-01

    Inter-laboratory reproducibility of Matrix Assisted Laser Desorption Time-of-Flight Mass Spectrometry (MALDI-TOF MS) of anaerobic bacteria has not been shown before. Therefore, ten anonymized anaerobic strains were sent to seven participating laboratories, an initiative of the European Network for the Rapid Identification of Anaerobes (ENRIA). On arrival the strains were cultured and identified using MALDI-TOF MS. The spectra derived were compared with two different Biotyper MALDI-TOF MS databases, the db5627 and the db6903. The results obtained using the db5627 shows a reasonable variation between the different laboratories. However, when a more optimized database is used, the variation is less pronounced. In this study we show that an optimized database not only results in a higher number of strains which can be identified using MALDI-TOF MS, but also corrects for differences in performance between laboratories. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Identification of Algerian Field-Caught Phlebotomine Sand Fly Vectors by MALDI-TOF MS.

    Directory of Open Access Journals (Sweden)

    Ismail Lafri

    2016-01-01

    Full Text Available Phlebotomine sand flies are known to transmit Leishmania parasites, bacteria and viruses that affect humans and animals in many countries worldwide. Precise sand fly identification is essential to prevent phlebotomine-borne diseases. Over the past two decades, progress in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS has emerged as an accurate tool for arthropod identification. The objective of the present study was to investigate the usefulness of MALDI-TOF MS as a tool for identifying field-caught phlebotomine.Sand flies were captured in four sites in north Algeria. A subset was morphologically and genetically identified. Six species were found in these areas and a total of 28 stored frozen specimens were used for the creation of the reference spectrum database. The relevance of this original method for sand fly identification was validated by two successive blind tests including the morphological identification of 80 new specimens which were stored at -80°C, and 292 unknown specimens, including engorged specimens, which were preserved under different conditions. Intra-species reproducibility and inter-species specificity of the protein profiles were obtained, allowing us to distinguish specimens at the gender level. Querying of the sand fly database using the MS spectra from the blind test groups revealed concordant results between morphological and MALDI-TOF MS identification. However, MS identification results were less efficient for specimens which were engorged or stored in alcohol. Identification of 362 phlebotomine sand flies, captured at four Algerian sites, by MALDI-TOF MS, revealed that the subgenus Larroussius was predominant at all the study sites, except for in M'sila where P. (Phlebotomus papatasi was the only sand fly species detected.The present study highlights the application of MALDI-TOF MS for monitoring sand fly fauna captured in the field. The low cost, reliability and

  20. Identification of Algerian Field-Caught Phlebotomine Sand Fly Vectors by MALDI-TOF MS.

    Science.gov (United States)

    Lafri, Ismail; Almeras, Lionel; Bitam, Idir; Caputo, Aurelia; Yssouf, Amina; Forestier, Claire-Lise; Izri, Arezki; Raoult, Didier; Parola, Philippe

    2016-01-01

    Phlebotomine sand flies are known to transmit Leishmania parasites, bacteria and viruses that affect humans and animals in many countries worldwide. Precise sand fly identification is essential to prevent phlebotomine-borne diseases. Over the past two decades, progress in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has emerged as an accurate tool for arthropod identification. The objective of the present study was to investigate the usefulness of MALDI-TOF MS as a tool for identifying field-caught phlebotomine. Sand flies were captured in four sites in north Algeria. A subset was morphologically and genetically identified. Six species were found in these areas and a total of 28 stored frozen specimens were used for the creation of the reference spectrum database. The relevance of this original method for sand fly identification was validated by two successive blind tests including the morphological identification of 80 new specimens which were stored at -80°C, and 292 unknown specimens, including engorged specimens, which were preserved under different conditions. Intra-species reproducibility and inter-species specificity of the protein profiles were obtained, allowing us to distinguish specimens at the gender level. Querying of the sand fly database using the MS spectra from the blind test groups revealed concordant results between morphological and MALDI-TOF MS identification. However, MS identification results were less efficient for specimens which were engorged or stored in alcohol. Identification of 362 phlebotomine sand flies, captured at four Algerian sites, by MALDI-TOF MS, revealed that the subgenus Larroussius was predominant at all the study sites, except for in M'sila where P. (Phlebotomus) papatasi was the only sand fly species detected. The present study highlights the application of MALDI-TOF MS for monitoring sand fly fauna captured in the field. The low cost, reliability and rapidity of MALDI-TOF

  1. Rapid identification and source-tracking of Listeria monocytogenes using MALDI-TOF mass spectrometry.

    Science.gov (United States)

    Jadhav, Snehal; Gulati, Vandana; Fox, Edward M; Karpe, Avinash; Beale, David J; Sevior, Danielle; Bhave, Mrinal; Palombo, Enzo A

    2015-06-02

    Listeria monocytogenes is an important foodborne pathogen responsible for the sometimes fatal disease listeriosis. Public health concerns and stringent regulations associated with the presence of this pathogen in food and food processing environments underline the need for rapid and reliable detection and subtyping techniques. In the current study, the application of matrix assisted laser desorption/ionisation-time-of-flight mass spectrometry (MALDI-TOF MS) as a single identification and source-tracking tool for a collection of L. monocytogenes isolates, obtained predominantly from dairy sources within Australia, was explored. The isolates were cultured on different growth media and analysed using MALDI-TOF MS at two incubation times (24 and 48 h). Whilst reliable genus-level identification was achieved from most media, identification at the species level was found to be dependent on culture conditions. Successful speciation was highest for isolates cultured on the chromogenic Agar Listeria Ottaviani Agosti agar (ALOA, 91% of isolates) and non-selective horse blood agar (HBA, 89%) for 24h. Chemometric statistical analysis of the MALDI-TOF MS data enabled source-tracking of L. monocytogenes isolates obtained from four different dairy sources. Strain-level discrimination was also observed to be influenced by culture conditions. In addition, t-test/analysis of variance (ANOVA) was used to identify potential biomarker peaks that differentiated the isolates according to their source of isolation. Source-tracking using MALDI-TOF MS was compared and correlated with the gold standard pulsed-field gel electrophoresis (PFGE) technique. The discriminatory index and the congruence between both techniques were compared using the Simpsons Diversity Index and adjusted Rand and Wallace coefficients. Overall, MALDI-TOF MS based source-tracking (using data obtained by culturing the isolates on HBA) and PFGE demonstrated good congruence with a Wallace coefficient of 0.71 and

  2. [Application of MALDI-TOF-MS in gene testing for non-syndromic hearing loss].

    Science.gov (United States)

    Zeng, Yun; Jiang, Dan; Feng, Da-fei; Jin, Dong-dong; Wu, Xiao-hui; Ding, Yan-li; Zou, Jing

    2013-12-01

    To investigate the feasibility of Matrix-Assisted Laser Desorption-Ionization Time of Flight Mass Spectrometry (MALDI-TOF-MS) , according to the genetic test of non-syndromic hearing loss (NSHL), and check using the direct sequencing. Peripheral blood was collected from 454 NSHL patients. DNA samples were extracted and 20 loci of the four common disease-causing genes were analysed by MALDI-TOF-MS, including GJB2 (35delG, 167delT, 176_191del16, 235delC, 299_300delAT ), GJB3 (538C→T, 547G→A), SLC26A4 (281C→T, 589G→A, IVS7-2A→G, 1174A→T, 1226G→A, 1229C→T, IVS15+5G→A, 1975G→C, 2027T→A, 2162C→T, 2168A→G), and mitochondrial 12S rRNA (1494C→T, 1555A→G). Direct sequencing was also used to analyse the aforementioned 20 loci in order to validate the accuracy of MALDI-TOF-MS. Among the 454 patients, 166 cases (36.56%) of disease-causing mutations were detected, which included 69 cases (21.15%) of GJB2 gene mutation, four cases (0.88%) of GJB3 gene mutation, 64 cases (14.10%) of SLC26A4 gene mutation, and three cases (0.66%) of mitochondrial 12S rRNA gene mutation. Moreover, the results obtained from direct sequencing and MALDI-TOF-MS were consistent, and the results showed that the two methods were consistent. The MALDI-TOF-MS detection method was designed based on the hearing loss-related mutation hotspots seen in the Chinese population, and it has a high detection rate for NSHL related mutations. In comparison to the conventional detection methods, MALDI-TOF-MS has the following advantages: more detection sites, greater coverage, accurate, high throughput and low cost. Therefore, this method is capable of satisfying the needs of clinical detection for hearing impairment and it is suitable for large-scale implementation.

  3. A comparative study of carbocyanine dyes measured with TOF-SIMS and other mass spectrometric techniques

    International Nuclear Information System (INIS)

    Adriaensen, L.; Vangaever, F.; Gijbels, R.

    2004-01-01

    A series of cationic, zwitterionic and anionic carbocyanine dyes have been measured with TOF-SIMS under Ga + bombardment. In contrast to the cationic dyes, which give very intense molecular ion and characteristic fragment signals in the positive mode, the anionic dyes produce only a few fragment signals of low intensity. Even in the negative mode no molecular ions of the anionic dyes are seen in the recorded spectra. Actually, none of the studied molecules produces negative SIMS spectra containing molecular information. A comparative study was made between TOF-SIMS and other mass spectrometric techniques, namely, fast atom bombardment (FAB), electro spray ionization (ESI) and matrix assisted laser desorption ionization (MALDI). The measurements show that MALDI, ESI as well as FAB all give rise to spectra containing molecular ion signals, either in the positive, in the negative or in both modes. Unlike with TOF-SIMS, this observation also applies to the anionic dyes. Characteristic fragments of the dyes are present in all the recorded spectra. However, TOF-SIMS appears to induce more fragment ions in comparison with the other techniques. ESI, for instance, produces hardly any molecular fragments. Finally, the kind of fragment ions recorded depends upon the technique used, though some signals are produced by various techniques. For these carbocyanine dyes there is no clear correlation between the mass spectra obtained with TOF-SIMS and spectra obtained with the other techniques. This points to different desorption/ionization mechanisms, and makes it difficult, in practice, to make predictions on the feasibility of TOF-SIMS, starting from results of the other MS techniques

  4. Assessment of heat treatment of dairy products by MALDI-TOF-MS.

    Science.gov (United States)

    Meltretter, Jasmin; Birlouez-Aragon, Inès; Becker, Cord-Michael; Pischetsrieder, Monika

    2009-12-01

    The formation of the Amadori product from lactose (protein lactosylation) is a major parameter to evaluate the quality of processed milk. Here, MALDI-TOF-MS was used for the relative quantification of lactose-adducts in heated milk. Milk was heated at a temperature of 70, 80, and 100 degrees C between 0 and 300 min, diluted, and subjected directly to MALDI-TOF-MS. The lactosylation rate of alpha-lactalbumin increased with increasing reaction temperature and time. The results correlated well with established markers for heat treatment of milk (concentration of total soluble protein, soluble alpha-lactalbumin and beta-lactoglobulin at pH 4.6, and fluorescence of advanced Maillard products and soluble tryptophan index; r=0.969-0.997). The method was also applied to examine commercially available dairy products. In severely heated products, protein pre-purification by immobilized metal affinity chromatography improved spectra quality. Relative quantification of protein lactosylation by MALDI-TOF-MS proved to be a very fast and reliable method to monitor early Maillard reaction during milk processing.

  5. Defining Diagnostic Biomarkers Using Shotgun Proteomics and MALDI-TOF Mass Spectrometry.

    Science.gov (United States)

    Armengaud, Jean

    2017-01-01

    Whole-cell MALDI-TOF has become a robust and widely used tool to quickly identify any pathogen. In addition to being routinely used in hospitals, it is also useful for low cost dereplication in large scale screening procedures of new environmental isolates for environmental biotechnology or taxonomical applications. Here, I describe how specific biomarkers can be defined using shotgun proteomics and whole-cell MALDI-TOF mass spectrometry. Based on MALDI-TOF spectra recorded on a given set of pathogens with internal calibrants, m/z values of interest are extracted. The proteins which contribute to these peaks are deduced from label-free shotgun proteomics measurements carried out on the same sample. Quantitative information based on the spectral count approach allows ranking the most probable candidates. Proteogenomic approaches help to define whether these proteins give the same m/z values along the whole taxon under consideration or result in heterogeneous lists. These specific biomarkers nicely complement conventional profiling approaches and may help to better define groups of organisms, for example at the subspecies level.

  6. Rapid typing of Mannheimia haemolytica major genotypes 1 and 2 using MALDI-TOF mass spectrometry

    Science.gov (United States)

    Genotype 2 M. haemolytica predominantly associate over genotype 1 with the lungs of cattle with respiratory disease and ICEs containing antimicrobial resistance genes. Distinct protein masses were detected by MALDI-TOF MS between genotype 1 and 2 strains. MALDI-TOF MS could rapidly differentiate ge...

  7. Mesures d’eficàcia publicitària i models teòrics de processament de la publicitat en formats off i online

    Directory of Open Access Journals (Sweden)

    Miriam Molina Garcia

    2013-06-01

    Full Text Available L’eficàcia publicitària ha estat i continua sent estudiada per diferents autors utilitzant varies mesures i establint diferents models. S’ha recollit estudis i investigacions dels sector i s’ha observat quines són algunes de les mesures més utilitzades per a l’estudi de l’eficàcia publicitària de formats off i online en els últims anys i en l’actualitat, els resultats són els següents; l’actitud cap a l’anunci (AA, l’actitud cap a la marca (AM, l’actitud cap al producte (AP i la intencionalitat de compra (IC. Amb el temps s’han creat diferents models teòrics per a l’estudi del processament de persuasió publicitària com el Elaboration Likelihood Model (ELM o el Advertising Response Modeling (ARM entre altres. En el present recull d’estudis s’observa com la gran majoria de models de persuasió publicitària no són vigents i funcionals per a l’estudi de l’eficàcia de la publicitat de formats interactius com poden ser els; banners, SMS’s, advergames o branded apps, amb l’excepció d’un model teòric clau que ha marcat un abans i un després en l’àrea d’estudi comentada, el ELM. Validity of theoretical models and advertising effectivness mesures with interactive advertising forms  Abstract The effectiveness of advertising has been and continues to be studied by different authors using various measures and establishing different models. Studies and  research has been collected and it has been observed which measures are most used for the study of advertising effectiveness in recent years and at present, the results are as follows; attitude toward the ad (AA, attitude toward the brand (AM, attitude toward the product (AP and purchase intention (IC. Over time, different theoretical models have been created to study the processing of persuasive advertising as the Elaboration Likelihood Model (ELM and the Advertising Response Modeling (ARM among others. This collection of studies shows how the

  8. New Insights for Diagnosis of Pineapple Fusariosis by MALDI-TOF MS Technique.

    Science.gov (United States)

    Santos, Cledir; Ventura, José Aires; Lima, Nelson

    2016-08-01

    Fusarium is one of the most economically important fungal genus, since it includes many pathogenic species which cause a wide range of plant diseases. Morphological or molecular biology identification of Fusarium species is a limiting step in the fast diagnosis and treatment of plant disease caused by these fungi. Mass spectrometry by matrix-assisted laser/desorption ionisation-time-of-flight (MALDI-TOF)-based fingerprinting approach was applied to the fungal growth monitoring and direct detection of strain Fusarium guttiforme E-480 inoculated in both pineapple cultivars Pérola and Imperial side shoots, that are susceptible and resistant, respectively, to this fungal strain. MALDI-TOF MS technique was capable to detect fungal molecular mass peaks in the susceptible pineapple stem side shoot tissue. It is assumed that these molecular masses are mainly constituted by ribosomal proteins. MALDI-TOF-based fingerprinting approach has herein been demonstrated to be sensitive and accurate for the direct detection of F. guttiforme E-480 molecular masses on both susceptible and resistant pineapple side stem free of any pre-treatment. According to the results obtained, the changing on molecular mass peaks of infected susceptible pineapple tissue together with the possibility of fungal molecular masses analysis into this pineapple tissue can be a good indication for an early diagnosis by MALDI-TOF MS of pineapple fusariosis.

  9. Calibración de cámaras de tiempo de vuelo: Ajuste adaptativo del tiempo de integración y análisis de la frecuencia de modulación

    Directory of Open Access Journals (Sweden)

    P. Gil

    2013-10-01

    Full Text Available Resumen: La percepción de profundidad se hace imprescindible en muchas tareas de manipulación, control visual y navegación de robots. Las cámaras de tiempo de vuelo (ToF: Time of Flight generan imágenes de rango que proporcionan medidas de profundidad en tiempo real. No obstante, el parámetro distancia que calculan estas cámaras es fuertemente dependiente del tiempo de integración que se configura en el sensor y de la frecuencia de modulación empleada por el sistema de iluminación que integran. En este artículo, se presenta una metodología para el ajuste adaptativo del tiempo de integración y un análisis experimental del comportamiento de una cámara ToF cuando se modifica la frecuencia de modulación. Este método ha sido probado con éxito en algoritmos de control visual con arquitectura ‘eye-in-hand’ donde el sistema sensorial está compuesto por una cámara ToF. Además, la misma metodología puede ser aplicada en otros escenarios de trabajo. Abstract: The depth perception is essential in many manipulation tasks, visual inspection and robot navigation. The cameras of Time of Flight (TOF generate range images which provide depth measurements in real time. However, the distance parameter computed from these cameras is strongly dependent on the integration time set for the sensor and the frequency of modulation used by the integrated lighting system. In this paper, a methodology for automatic setting of integration time and an experimental analysis of ToF camera behavior adjusting its modulation frequency is presented. This method has been successfully tested on visual servoing algorithms with architecture ‘eye-in-hand’ in which the sensory system consists of a ToF camera, in addition this methodology can be applied to other workspaces and scenarios. Palabras clave: Tiempo de vuelo, calibración, imagen de rango, percepción robótica, cámaras 3D, Keywords

  10. Absolute measurement of {beta} emitters with a 4 {pi} counter; Mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Le Gallic, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-06-15

    The object of this work is to investigate the conditions under which the activity of {beta}-emitting radionuclides may be measured with a maximum of precision, and as a result to study the relevant corrections. The various problems relating to activity measurements with a 4 {pi} counter have been examined successively: - comparison of 4 {pi}, GM and proportional counters; - study of the preparation of sources; - corrections on the counting of sources; - self-absorption; - correction for absorption. The precision obtained on these measurements varies from 1.2 to 3 per cent, with the result that the 4 {pi} counter can be considered a very satisfactory calibration instrument. (author) [French] Le but de ce travail est de rechercher les conditions permettant d'obtenir avec le maximum de precision, la mesure de l'activite des radionuclides se desintegrant par emission et par consequent d'etudier les corrections qui s'y rapportent. Nous avons examine successivement les differents problemes se rapportant aux mesures d'activite au compteur 4 {pi}: - Comparaison des compteurs 4 {pi}, GM et proportionnel; - etude de la preparation des sources; - corrections sur la numeration des sources; - auto-absorption; - correction d'absorption. La precision obtenue dans ces mesures, variant de 1,2 a 3 pour cent, on peut donc considerer le compteur 4 {pi} comme un instrument d'etalonnage tres satisfaisant. (auteur)

  11. Absolute measurement of {beta} emitters with a 4 {pi} counter; Mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Le Gallic, Y. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-06-15

    The object of this work is to investigate the conditions under which the activity of {beta}-emitting radionuclides may be measured with a maximum of precision, and as a result to study the relevant corrections. The various problems relating to activity measurements with a 4 {pi} counter have been examined successively: - comparison of 4 {pi}, GM and proportional counters; - study of the preparation of sources; - corrections on the counting of sources; - self-absorption; - correction for absorption. The precision obtained on these measurements varies from 1.2 to 3 per cent, with the result that the 4 {pi} counter can be considered a very satisfactory calibration instrument. (author) [French] Le but de ce travail est de rechercher les conditions permettant d'obtenir avec le maximum de precision, la mesure de l'activite des radionuclides se desintegrant par emission et par consequent d'etudier les corrections qui s'y rapportent. Nous avons examine successivement les differents problemes se rapportant aux mesures d'activite au compteur 4 {pi}: - Comparaison des compteurs 4 {pi}, GM et proportionnel; - etude de la preparation des sources; - corrections sur la numeration des sources; - auto-absorption; - correction d'absorption. La precision obtenue dans ces mesures, variant de 1,2 a 3 pour cent, on peut donc considerer le compteur 4 {pi} comme un instrument d'etalonnage tres satisfaisant. (auteur)

  12. Reproducibility in protein profiling by MALDI-TOF mass spectrometry

    DEFF Research Database (Denmark)

    Albrethsen, Jakob

    2007-01-01

    , immunocapture, prestructured target surfaces, standardized matrix (co)crystallization, improved MALDI-TOF MS instrument components, internal standard peptides, quality-control samples, replicate measurements, and algorithms for normalization and peak detection. CONCLUSIONS: Further evaluation and optimization...

  13. Lidiam - direct-link computer for the photo measurement apparatus of a bubble chamber; Lidiam - liaison directe d'une calculatrice aux appareils de mesure de photos de chambre a bulles

    Energy Technology Data Exchange (ETDEWEB)

    Deler, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The treatment of bubble chamber pictures can be considerably improved by connecting conventional measuring machines to a small computer providing continuous control of the later as well as the immediate detection of errors and their immediate corrections. The computer will also perform first processing of the measured data. In addition the system described will improve the effective yield of each apparatus and facilitates the control of the data. A description is given here of the apparatus and of some future extensions. (author) [French] L'exploitation des cliches de chambre a bulles peut etre sensiblement amelioree par la jonction directe des appareils de mesure a une calculatrice qui permettra la detection immediate des erreurs et leurs corrections, le controle continu des appareils et un premier traitement des evenements mesures. De plus, le rendement effectif des appareils de mesure sera notablement augmente et la gestion ainsi que l'exploitation des mesures grandement facilitees. Nous presentons ici la description d'un dispositif de ce genre ainsi que les projets d'extensions envisagees.

  14. MALDI-TOF MS as a tool to identify foodborne yeasts and yeast-like fungi.

    Science.gov (United States)

    Quintilla, Raquel; Kolecka, Anna; Casaregola, Serge; Daniel, Heide M; Houbraken, Jos; Kostrzewa, Markus; Boekhout, Teun; Groenewald, Marizeth

    2018-02-02

    Since food spoilage by yeasts causes high economic losses, fast and accurate identifications of yeasts associated with food and food-related products are important for the food industry. In this study the efficiency of the matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) to identify food related yeasts was evaluated. A CBS in-house MALDI-TOF MS database was created and later challenged with a blinded test set of 146 yeast strains obtained from food and food related products. Ninety eight percent of the strains were correctly identified with log score values>1.7. One strain, Mrakia frigida, gained a correct identification with a score value1.7. Ambiguous identifications were observed due to two incorrect reference mass spectra's found in the commercial database BDAL v.4.0, namely Candida sake DSM 70763 which was re-identified as Candida oleophila, and Candida inconspicua DSM 70631 which was re-identified as Pichia membranifaciens. MALDI-TOF MS can distinguish between most of the species, but for some species complexes, such as the Kazachstania telluris and Mrakia frigida complexes, MALDI-TOF MS showed limited resolution and identification of sibling species was sometimes problematic. Despite this, we showed that the MALDI-TOF MS is applicable for routine identification and validation of foodborne yeasts, but a further update of the commercial reference databases is needed. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. TOF technique for laser-driven proton beam diagnostics for the ELIMED beamline

    International Nuclear Information System (INIS)

    Milluzzo, G.; Scuderi, V.; Amico, A.G.; Cirrone, G.A.P.; Cuttone, G.; Larosa, G.; Leanza, R.; Petringa, G.; Pipek, J.; Romano, F.; Napoli, M. De; Dostal, J.; Margarone, D.; Schillaci, F.; Velyhan, A.

    2017-01-01

    The Time of Flight (TOF) method for laser-driven ion beam diagnostics has been extensively investigated so far for low energy ion diagnostics and several works, reported in literature [1,2], have shown its efficiency in the measurement of particle beam characteristics such as ion species, energy spectrum and current. Moreover, such technique allows obtaining a shot-to-shot on-line monitoring of optically accelerated particles, necessary to control the reproducibility of the accelerated beam and to deliver a beam suitable for any kind of applications. For this reason, the ELIMED beamline [3,4], which will be entirely developed at INFN-LNS and installed in 2017 within the ion beamline ELIMAIA (ELI Multidisciplinary Applications of laser-Ion Acceleration) experimental hall at ELI-Beamlines in Prague, will be equipped with an on-line diagnostics system composed by silicon carbide and diamond detectors, using the TOF technique. In this contribution, the procedure developed for TOF signal analysis will be briefly reported.

  16. Rapid identification of acetic acid bacteria using MALDI-TOF mass spectrometry fingerprinting.

    Science.gov (United States)

    Andrés-Barrao, Cristina; Benagli, Cinzia; Chappuis, Malou; Ortega Pérez, Ruben; Tonolla, Mauro; Barja, François

    2013-03-01

    Acetic acid bacteria (AAB) are widespread microorganisms characterized by their ability to transform alcohols and sugar-alcohols into their corresponding organic acids. The suitability of matrix-assisted laser desorption-time of flight mass spectrometry (MALDI-TOF MS) for the identification of cultured AAB involved in the industrial production of vinegar was evaluated on 64 reference strains from the genera Acetobacter, Gluconacetobacter and Gluconobacter. Analysis of MS spectra obtained from single colonies of these strains confirmed their basic classification based on comparative 16S rRNA gene sequence analysis. MALDI-TOF analyses of isolates from vinegar cross-checked by comparative sequence analysis of 16S rRNA gene fragments allowed AAB to be identified, and it was possible to differentiate them from mixed cultures and non-AAB. The results showed that MALDI-TOF MS analysis was a rapid and reliable method for the clustering and identification of AAB species. Copyright © 2012 Elsevier GmbH. All rights reserved.

  17. Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT--Initial Results.

    Science.gov (United States)

    Zeimpekis, Konstantinos G; Barbosa, Felipe; Hüllner, Martin; ter Voert, Edwin; Davison, Helen; Veit-Haibach, Patrick; Delso, Gaspar

    2015-10-01

    The purpose of this study was to compare only the performance of the PET component between a TOF-PET/CT (henceforth noted as PET/CT) scanner and an integrated TOF-PET/MRI (henceforth noted as PET/MRI) scanner concerning image quality parameters and quantification in terms of standardized uptake value (SUV) as a function of acquisition time (a surrogate of dose). The CT and MR image quality were not assessed, and that is beyond the scope of this study. Five brain and five whole-body patients were included in the study. The PET/CT scan was used as a reference and the PET/MRI acquisition time was consecutively adjusted, taking into account the decay between the scans in order to expose both systems to the same amount of the emitted signal. The acquisition times were then retrospectively reduced to assess the performance of the PET/MRI for lower count rates. Image quality, image sharpness, artifacts, and noise were evaluated. SUV measurements were taken in the liver and in the white matter to compare quantification. Quantitative evaluation showed strong correlation between PET/CT and PET/MRI brain SUVs. Liver correlation was good, however, with lower uptake estimation in PET/MRI, partially justified by bio-redistribution. The clinical evaluation showed that PET/MRI offers higher image quality and sharpness with lower levels of noise and artifacts compared to PET/CT with reduced acquisition times for whole-body scans while for brain scans there is no significant difference. The TOF-PET/MRI showed higher image quality compared to TOF-PET/CT as tested with reduced imaging times. However, this result accounts mainly for body imaging, while no significant differences were found in brain imaging.

  18. Matrix normalized MALDI-TOF quantification of a fluorotelomer-based acrylate polymer.

    Science.gov (United States)

    Rankin, Keegan; Mabury, Scott A

    2015-05-19

    The degradation of fluorotelomer-based acrylate polymers (FTACPs) has been hypothesized to serve as a source of the environmental contaminants, perfluoroalkyl carboxylates (PFCAs). Studies have relied on indirect measurement of presumed degradation products to evaluate the environmental fate of FTACPs; however, this approach leaves a degree of uncertainty. The present study describes the development of a quantitative matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry method as the first direct analysis method for FTACPs. The model FTACP used in this study was poly(8:2 FTAC-co-HDA), a copolymer of 8:2 fluorotelomer acrylate (8:2 FTAC) and hexadecyl acrylate (HDA). Instead of relying on an internal standard polymer, the intensities of 40 poly(8:2 FTAC-co-HDA) signals (911-4612 Da) were normalized to the signal intensity of a matrix-sodium cluster (659 Da). We termed this value the normalized polymer response (P(N)). By using the same dithranol solution for the sample preparation of poly(8:2 FTAC-co-HDA) standards, calibration curves with coefficient of determinations (R(2)) typically >0.98 were produced. When poly(8:2 FTAC-co-HDA) samples were prepared with the same dithranol solution as the poly(8:2 FTAC-co-HDA) standards, quantification to within 25% of the theoretical concentration was achieved. This approach minimized the sample-to-sample variability that typically plagues MALDI-TOF, and is the first method developed to directly quantify FTACPs.

  19. RPC HADES-TOF wall cosmic ray test performance

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, A., E-mail: alberto@coimbra.lip.pt [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); Belver, D.; Cabanelas, P. [LabCAF, Universidade de Santiago de Compostela, USC, Santiago de Compostela (Spain); Diaz, J. [Instituto de Fisica Corpuscular IFIC (CSIC-Universidad de Valencia), Valencia (Spain); Fonte, P. [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); Instituto Superior de Engenharia de Coimbra, ISEC, Coimbra (Portugal); Garzon, J.A. [LabCAF, Universidade de Santiago de Compostela, USC, Santiago de Compostela (Spain); Gil, A. [Instituto de Fisica Corpuscular IFIC (CSIC-Universidad de Valencia), Valencia (Spain); Gonzalez-Diaz, D.; Koenig, W.; Kolb, B. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Lopes, L. [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); Palka, M. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Pereira, A. [Laboratorio de Instrumentacao e Fisica Experimental de Particulas, LIP, Coimbra (Portugal); and others

    2012-01-01

    In this work we present results concerning the cosmic ray test, prior to the final installation and commissioning of the new Resistive Plate Chamber (RPC) Time of Flight (TOF) wall for the High-Acceptance DiElectron Spectrometer (HADES) at GSI. The TOF wall is composed of six equal sectors, each one constituted by 186 individual 4-gaps glass-aluminium shielded RPC cells distributed in six columns and 31 rows in two partially overlapping layers, covering an area of 1.26 m{sup 2}. All sectors were tested with the final Front End Electronic (FEE) and Data AcQuisition system (DAQ) together with Low Voltage (LV) and High Voltage (HV) systems. Results confirm a very uniform average system time resolution of 77 ps sigma together with an average multi-hit time resolution of 83 ps. Crosstalk levels below 1% (in average), moderate timing tails along with an average longitudinal position resolution of 8.4 mm sigma are also confirmed.

  20. RPC HADES-TOF wall cosmic ray test performance

    International Nuclear Information System (INIS)

    Blanco, A.; Belver, D.; Cabanelas, P.; Díaz, J.; Fonte, P.; Garzon, J.A.; Gil, A.; Gonzalez-Díaz, D.; Koenig, W.; Kolb, B.; Lopes, L.; Palka, M.; Pereira, A.

    2012-01-01

    In this work we present results concerning the cosmic ray test, prior to the final installation and commissioning of the new Resistive Plate Chamber (RPC) Time of Flight (TOF) wall for the High-Acceptance DiElectron Spectrometer (HADES) at GSI. The TOF wall is composed of six equal sectors, each one constituted by 186 individual 4-gaps glass-aluminium shielded RPC cells distributed in six columns and 31 rows in two partially overlapping layers, covering an area of 1.26 m 2 . All sectors were tested with the final Front End Electronic (FEE) and Data AcQuisition system (DAQ) together with Low Voltage (LV) and High Voltage (HV) systems. Results confirm a very uniform average system time resolution of 77 ps sigma together with an average multi-hit time resolution of 83 ps. Crosstalk levels below 1% (in average), moderate timing tails along with an average longitudinal position resolution of 8.4 mm sigma are also confirmed.

  1. Appareillage automatisé de mesure simultanée du pouvoir thermoélectrique et de la conductivité électrique. Application à l'étude de couches polymères semi-conductrices

    Science.gov (United States)

    Moliton, A.; Ratier, B.; Moreau, C.; Froyer, G.

    1991-05-01

    In this paper, we present an automatized system for simultaneous measurement of conductivity σ, and thermoelectric power S : measurements are allowed for temperatures ranging from 130 K to 360 K on brittle semiconductor layers. As an example of the application, results obtained in the case of polymer (PPP) layers implanted with Na ions are presented : with high energy implantation (E = 250 keV) we observe only a defect semiconduction of p type while at low energy (30 keV) an electronic n type conduction appears. Nous présentons dans cet article un système de mesure simultanée de la conductivité σ, et du pouvoir thermoélectrique S : il permet des mesures en fonction de la température (entre 130 K et 360 K) dans le cas de couches semi-conductrices relativement fragiles. A titre d'application, nous indiquons les résultats que nous avons obtenus dans le cas de couches polymères (PPP) implantées avec des ions sodium: alors que seule une semi-conduction par défaut est générée par de fortes énergies d'implantation (E = 250 keV ), il apparaît une semiconduction induite par le dopage n lors d'implantations à basse énergie (E = 30 keV ).

  2. Plasma-laser ion discrimination by TOF technique applied to coupled SiC detectors.

    Science.gov (United States)

    Cavallaro, Salvatore

    2018-01-01

    The rate estimation of nuclear reactions induced in high intensity laser-target interaction (≥1016 W/cm2), is strongly depending on the neutron detection efficiency and ion charge discrimination, according to particles involved in exit open-channels. Ion discrimination is basically performed by means of analysis of pits observed on track detector, which is critically dependent on calibration and/or fast TOF devices based on SiC and diamond detectors. Last setup is used to determine the ion energy and to obtain a rough estimation of yields. However, for each TOF interval, the dependence of yield from the energy deposited in the detector sensitive region, introduces a distortion in the ion spectra. Moreover, if two ion species are present in the same spectrum, the discrimination of their contribution is not attainable. In this paper a new method is described which allows to discriminate the contribution of two ion species in the wide energy range of nuclear reactions induced in laser-target interactions. The method is based on charge response of two TOF-SiC detectors, of suitable thicknesses, placed in adjacent positions. In presence of two ion species, the response of the detectors, associated with different energy losses, can determine the ion specific contribution to each TOF interval.

  3. Mesurer le droit de participer à la vie culturelle: le développement des indicateurs

    NARCIS (Netherlands)

    Donders, Y.; Bouchard, J.; Gandolfi, S.; Meyer-Bisch, P.

    2013-01-01

    Dans les domaines des droits de l'homme, de la culture et du développement, des cadres et mécanismes sont développés afin de mesurer et de qualifier les relations entre ces domaines et leur impact sur la vie des individus en des communautés. Les indicateurs constituent un élément important de ces

  4. Resistivity measurements using a direct current induction method (1963); Mesure de resistivite par la methode d'induction en courant continu (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Delaplace, J; Hillairet, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The conventional methods for measuring electrical resistivities necessitate the fixing of electrical contacts on the sample either mechanically or by soldering. Furthermore it is also necessary to carry,out the measurements on low cross-section samples which are not always easy to obtain. Our direct-current induction method on the other hand requires no contacts and can easily be applied to samples of large cross-section. The sample is placed in a uniform magnetic field; at the moment when the current is cut, eddy currents appear in the sample which tend to oppose the disappearance of the field. The way in which the magnetic flux decreases in the sample makes it possible to determine the resistivity of the material. This method has been applied to samples having diameters of between 1 and 30 mm in the case of metals which are good conductors. It gives a value for the local resistivity and makes it possible to detect any variation along a sample. The measurements can be carried out at all temperature from a few degrees absolute to 500 deg. C. We have used the induction method to follow the purification of beryllium by zone-melting; it is in effect possible to estimate the purity of a material by resistivity measurements. We have measured the resistivity along each bar treated by the zone-melting technique and have thus, localised the purest section. High temperature measurements have been carried out on uranium carbide and on iron-aluminium alloys. This method constitutes an interesting means of investigation the resistivity of solid materials. Its accuracy and rapidity make it particularly adapted both to fundamental research and to production control. (authors) [French] Les methodes classiques de mesure de resistivite electrique imposent la realisation sur l'echantillon de contacts electriques obtenus soit mecaniquement, soit par soudure. En outre, elles demandent, le plus souvent, d'effectuer les mesures sur des echantillons de faible section qu'il n'est pas

  5. Improved mass resolution and mass accuracy in TOF-SIMS spectra and images using argon gas cluster ion beams.

    Science.gov (United States)

    Shon, Hyun Kyong; Yoon, Sohee; Moon, Jeong Hee; Lee, Tae Geol

    2016-06-09

    The popularity of argon gas cluster ion beams (Ar-GCIB) as primary ion beams in time-of-flight secondary ion mass spectrometry (TOF-SIMS) has increased because the molecular ions of large organic- and biomolecules can be detected with less damage to the sample surfaces. However, Ar-GCIB is limited by poor mass resolution as well as poor mass accuracy. The inferior quality of the mass resolution in a TOF-SIMS spectrum obtained by using Ar-GCIB compared to the one obtained by a bismuth liquid metal cluster ion beam and others makes it difficult to identify unknown peaks because of the mass interference from the neighboring peaks. However, in this study, the authors demonstrate improved mass resolution in TOF-SIMS using Ar-GCIB through the delayed extraction of secondary ions, a method typically used in TOF mass spectrometry to increase mass resolution. As for poor mass accuracy, although mass calibration using internal peaks with low mass such as hydrogen and carbon is a common approach in TOF-SIMS, it is unsuited to the present study because of the disappearance of the low-mass peaks in the delayed extraction mode. To resolve this issue, external mass calibration, another regularly used method in TOF-MS, was adapted to enhance mass accuracy in the spectrum and image generated by TOF-SIMS using Ar-GCIB in the delayed extraction mode. By producing spectra analyses of a peptide mixture and bovine serum albumin protein digested with trypsin, along with image analyses of rat brain samples, the authors demonstrate for the first time the enhancement of mass resolution and mass accuracy for the purpose of analyzing large biomolecules in TOF-SIMS using Ar-GCIB through the use of delayed extraction and external mass calibration.

  6. Aspects et mesure de la qualité de vie : évolution et renouvellement des tableaux de bord métropolitains

    Directory of Open Access Journals (Sweden)

    Pierre J. Hamel

    2008-02-01

    Full Text Available La mesure de la qualité de vie à l’intérieur des espaces urbains préoccupe les administrations publiques depuis nombre d’années. Cet article passe en revue les modèles de mesure de la qualité de vie développés par les métropoles canadiennes. Il s’interroge sur l’évolution de ces modèles de mesure et sur leur capacité à rendre compte des différentes problématiques désormais associées à la notion de qualité de vie comme le développement social, l’environnement, la société du risque, les ambiances urbaines ou la compétitivité urbaine.For a number of years now, government bodies at all levels have been concerned with measuring quality of life within urban areas. This paper reviews the models used by Canada’s metropolises to measure quality of life. It examines how the models have evolved and their capacity to consider various issues which have become associated with the notion of quality of life, such as social development, environment, risk society, urban surroundings, or urban competitiveness.

  7. TOF neutron diffraction study of archaeological ceramics

    International Nuclear Information System (INIS)

    Kockelmann, W.; Kirfel, A.

    1999-01-01

    Complete text of publication follows. The time-of flight (TOF) neutron diffractometer ROTAX [1] at ISIS has been used for identification and quantitative phase analysis of archaeological pottery. Neutron diffraction yields mineral phase fractions which, in parallel with information obtained from other archaeometric examination techniques, can provide a fingerprint that can be used to identify provenance and reconstruct methods of manufacturing of an archaeological ceramic product. Phase fractions obtained from a 13th century Rhenish stoneware jar compare well with those obtained from a powder sample prepared from the same fragment. This indicates that reliable results can be obtained by illuminating a large piece or even an intact ceramic object making TOF neutron diffraction a truly non-destructive examination technique. In comparison to X-ray diffraction, information from the bulk sample rather than from surface regions is obtained. ROTAX allows for a simple experimental set-up, free of sample movements. Programmes of archaeological study on ROTAX involve Russian samples (Upper-Volga culture, 5000-2000 BC), Greek pottery, (Agora/Athens, 500-300 BC), and medieval German earthenware and stoneware ceramics (Siegburg waster heap, 13-15th century). (author)

  8. Development of TOF-PET using Compton scattering by plastic scintillators

    International Nuclear Information System (INIS)

    Kuramoto, M.; Nakamori, T.; Kimura, S.; Gunji, S.; Takakura, M.; Kataoka, J.

    2017-01-01

    We propose a time-of-flight (TOF) technique using plastic scintillators which have fast decay time of a few ns for positron emission tomography (PET). While the photoelectric absorption probability of the plastic for 511 keV gamma rays are extremely low due to its small density and effective atomic number, the cross section of Compton scattering is comparable to that of absorption by conventional inorganic scintillators. We thus propose TOF-PET using Compton scattering with plastic scintillators (Compton-PET), and performed fundamental experiments towards exploration of the Compton-PET capability. We demonstrated that the plastic scintillators achieved the better time resolution in comparison to LYSO(Ce) and GAGG(Ce) scintillators. In addition we evaluated the depth-of-interaction resolving capability with the plastic scintillators.

  9. Development of TOF-PET using Compton scattering by plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Kuramoto, M., E-mail: kuramoto@maxwell.kj.yamagata-u.ac.jp [Yamagata University, Kojirakawa 1-4-12, Yamagata 990-8560 (Japan); Nakamori, T., E-mail: nakamori@maxwell.kj.yamagata-u.ac.jp [Yamagata University, Kojirakawa 1-4-12, Yamagata 990-8560 (Japan); Kimura, S.; Gunji, S.; Takakura, M. [Yamagata University, Kojirakawa 1-4-12, Yamagata 990-8560 (Japan); Kataoka, J. [Waseda University, Okubo 3-4-1, Shinjuku, Tokyo 169-8555 (Japan)

    2017-02-11

    We propose a time-of-flight (TOF) technique using plastic scintillators which have fast decay time of a few ns for positron emission tomography (PET). While the photoelectric absorption probability of the plastic for 511 keV gamma rays are extremely low due to its small density and effective atomic number, the cross section of Compton scattering is comparable to that of absorption by conventional inorganic scintillators. We thus propose TOF-PET using Compton scattering with plastic scintillators (Compton-PET), and performed fundamental experiments towards exploration of the Compton-PET capability. We demonstrated that the plastic scintillators achieved the better time resolution in comparison to LYSO(Ce) and GAGG(Ce) scintillators. In addition we evaluated the depth-of-interaction resolving capability with the plastic scintillators.

  10. Development of TOF-PET using Compton scattering by plastic scintillators

    Science.gov (United States)

    Kuramoto, M.; Nakamori, T.; Kimura, S.; Gunji, S.; Takakura, M.; Kataoka, J.

    2017-02-01

    We propose a time-of-flight (TOF) technique using plastic scintillators which have fast decay time of a few ns for positron emission tomography (PET). While the photoelectric absorption probability of the plastic for 511 keV gamma rays are extremely low due to its small density and effective atomic number, the cross section of Compton scattering is comparable to that of absorption by conventional inorganic scintillators. We thus propose TOF-PET using Compton scattering with plastic scintillators (Compton-PET), and performed fundamental experiments towards exploration of the Compton-PET capability. We demonstrated that the plastic scintillators achieved the better time resolution in comparison to LYSO(Ce) and GAGG(Ce) scintillators. In addition we evaluated the depth-of-interaction resolving capability with the plastic scintillators.

  11. Application of MALDI-TOF mass spectrometry in clinical diagnostic microbiology.

    Science.gov (United States)

    De Carolis, Elena; Vella, Antonietta; Vaccaro, Luisa; Torelli, Riccardo; Spanu, Teresa; Fiori, Barbara; Posteraro, Brunella; Sanguinetti, Maurizio

    2014-09-12

    Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently emerged as a powerful technique for identification of microorganisms, changing the workflow of well-established laboratories so that its impact on microbiological diagnostics has been unparalleled. In comparison with conventional identification methods that rely on biochemical tests and require long incubation procedures, MALDI-TOF MS has the advantage of identifying bacteria and fungi directly from colonies grown on culture plates in a few minutes and with simple procedures. Numerous studies on different systems available demonstrate the reliability and accuracy of the method, and new frontiers have been explored besides microbial species level identification, such as direct identification of pathogens from positive blood cultures, subtyping, and drug susceptibility detection.

  12. Determination of the concentration of {alpha} emitting radioactive aerosols; Mesure de la concentration des aerosols radioactifs emetteurs {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Labeyrie, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-06-15

    In the first part of this work the techniques used for the quantitative measurement of the concentrations of aerosols carrying short lived (radon or thoron daughters) or long lived (uranium) {alpha} radioactive emitters are described. In the second part the author investigates the problem of the determination of radon concentration in air by means of activity determinations on airborne dusts. Special reference is made to the measurement of the radon active deposit on two types of dusts (iron oxide (yellow) and uranium oxide) in small chambers (6 liters). In the third part are given data resulting from determinations of radon and thoron concentrations in atmospheric air in the south of Paris area using this method. (author) [French] Dans la premiere partie de ce travail on expose les techniques utilisees pour la mesure quantitative des concentrations d'aerosols contenant des emetteurs radioactifs {alpha}, tant pour ceux a vie courte (derives du radon ou du thoron) que pour ceux a vie longue (uranium). Dans la seconde partie on traite le probleme de la determination de la concentration de l'air en radon par la mesure de l'activite des poussieres ayant sejourne dans cet air. En particulier, on indique pour de petits volumes (6 litres) la proportion de depot actif du radon qui est fixee sur deux types de poussieres (limonite et oxyde d'uranium) en fonction de la concentration de celles-ci. Dans la troisieme partie on donne quelques exemples de mesure par cette methode de la concentration en radon et en thoron de l'atmosphere de la region parisienne. (auteur)

  13. Bonheur et progrès : mesurer le bien-être au Bhoutan et au Canada ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    31 janv. 2011 ... Étant l'un des pays les moins développés, le Bhoutan s'inquiète de la mondialisation et il est déterminé à protéger sa spécificité culturelle. Il veut préserver ses valeurs sociales en les ancrant dans des termes que le monde entier pourra comprendre et respecter, c'est-à-dire en les quantifiant. En mesurant ...

  14. 124Xe(n,γ)125Xe and 124Xe(n,2n)123Xe measurements for National Ignition Facility

    Science.gov (United States)

    Bhike, Megha; Ludin, Nurin; Tornow, Werner

    2015-05-01

    The cross section for the 124Xe(n,γ)125Xe reaction has been measured for the first time for neutron energies above 100 keV. In addition, the 124Xe(n,2n)123Xe reaction has been studied between threshold and 14.8 MeV. The results of these measurements provide sensitive diagnostic tools for investigating properties of the inertial confinement fusion plasma in Deuterium-Tritium (DT) capsules at the National Ignition Facility (NIF) located at Lawrence Livermore National Laboratory.

  15. Direct measurement of the 7Be(n, α4 He reaction cross sections for the cosmological Li problem

    Directory of Open Access Journals (Sweden)

    Kawabata Takahiro

    2017-01-01

    Full Text Available The cross sections of the 7Be(n, α4He reaction for p-wave neutrons were experimentally determined at Ec.m. = 0.20−0.81 MeV close to the Big Bang nucleosynthesis (BBN energy window for the first time on the basis of the detailed balance principle by measuring the time-reverse reaction. The obtained cross sections are much larger than the cross sections for s-wave neutrons inferred from the recent measurement at the n_TOF facility in CERN, but significantly smaller than the theoretical estimation widely used in the BBN calculations. The present results suggest the 7Be(n, α4 He reaction rate is not large enough to solve the cosmological lithium problem

  16. Limit to the measurement of feeble activities using ionization chambers; Limite des possibilites de mesure de faibles activites au moyen de chambres d'ionisation

    Energy Technology Data Exchange (ETDEWEB)

    Briere, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The present account based on experience acquired in the Biology Service, in measuring feeble activities of tritium and carbon-14 has been prepared for the benefit hose who have to carry out measurements of feeble activities using ionization chambers. Precision are given on the behaviour and actual performance of vibrating condenser electrometers, based on approximately two years operating experience. It is shown that the possibilities of utilisation are not limited as is generally believed by insufficient sensitivity and stability of the electronic equipment, but by the existence of various parasitic phenomena coming from the ionization chamber itself, which make very difficult the measurement of ionization currents which are less than 10{sup -14} A. (author)Fren. [French] Le present compte rendu, base sur l'experience acquise au Service de Biologie dans la mesure de faibles activites de tritium et de carbone-14, est redige a l'intention des personnes ayant a effectuer des mesures de tres faibles activites au moyen de chambres d'ionisation. Il donne des precisions sur le comportement et les performances reelles des electrometres a condensateur vibrant, basees sur environ deux ans d'utilisation, et demontre que les possibilites de mesure ne sont pas limitees - comme on le croit generalement - par l'insuffisance de sensibilite et de stabilite de l'appareillage electronique, mais par l'existence de divers phenomenes parasites dont la chambre d'ionisation est le siege et qui rendent tres difficiles la mesure de courants d'ionisation inferieurs a 10{sup -14} A. (auteur)

  17. MALDI-TOF mass spectrometry confirms difficulties in separating species of the Avibacterium genus

    DEFF Research Database (Denmark)

    Alispahic, Merima; Christensen, Henrik; Bisgaard, Magne

    2014-01-01

    In the present study a well-characterized strain collection (n = 33) of Avibacterium species was investigated by matrix-assisted laser desorption ionization-time-of flight mass spectrometry (MALDI-TOF MS). The robustness of the currently available reference database (Bruker Biotyper 3.0) was tested...... to determine the degree of identification of these strains. Reproducible signal patterns were obtained from all strains. However, identification of most strains was only possible at genus level. Furthermore, two strains could not be identified by this method. Based on their protein spectra profiles, a MALDI...

  18. In-beam test of the RPC architecture foreseen to be used for the CBM-TOF inner wall

    Science.gov (United States)

    Petriş, M.; Bartoş, D.; Petrovici, M.; Rădulescu, L.; Simion, V.; Deppner, I.; Herrmann, N.; Simon, C.; Frühauf, J.; Kiš, M.; Loizeau, P.-A.

    2018-05-01

    The Time Of Flight (TOF) subsystem is one of the main detectors of the CBM experiment. The TOF wall in conjunction with Silicon Tracking System (STS) is foreseen to identify charged hadrons, i.e. pions, kaons and protons, with a full azimuthal coverage at 2.50 - 250 polar angles. A system time resolution of at least 80 ps, including all contributions, such as electronics jitter and the resolution of the time reference system, is required. Such a performance should be maintained up to a counting rate larger than 30 kHz/cm2 at the most inner region of TOF wall. Our R&D activity has been focused on the development of two-dimensional position sensitive Multi-gap Resistive Plate Counter (MRPC) prototypes for the forward region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The in-beam tests using secondary particles produced in 30 GeV/u Pb ion collisions on a Pb target at SPS - CERN aimed to test the performance of these prototypes in conditions similar to the ones expected at SIS100 at FAIR. The performance of the prototypes is studied in conditions of exposure of the whole active area of the chamber to high multiplicity of reaction products. The results show that this type of MRPC fulfill the challenging requirements of the CBM-TOF wall. Therefore, such an architecture is recommended as basic solution for CBM-TOF inner zone.

  19. Application of the similitude principle to gamma-gamma density measurements; Application du principe de similitude a la mesure gamma-gamma de densite

    Energy Technology Data Exchange (ETDEWEB)

    Czubek, J A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement d' Electronique Generale, Service d' Electronique Industrielle; Institut de Recherches Nucleaires, Dep. VI, Cracow (Poland)

    1966-07-01

    The work presented here deals with the problem of the application of the similitude principle to rock density measurements by the gamma-gamma method. A formula is presented which makes it possible to transform results of gamma-gamma measurements carried out on models in order to make them suitable for comparison with results obtained under actual field conditions. Both the space coordinates and the densities are transformed. This transformation makes it possible to obtain a calibration curve as a function of the density for a gamma-gamma probe using only a single model of given density. The influence has also been studied of the chemical composition on the results obtained from gamma-gamma measurements. A method has been developed for estimating the equivalent Z parameter of the medium; the possibility of completely eliminating the influence of the chemical composition of the medium on the measurement results has been studied. (author) [French] L'etude presentee ci-dessous traite le probleme de l'application du principe de similitude aux mesures de densite des roches par la methode gamma-gamma. Nous indiquons une formule qui permet de transformer les resultats des mesures gamma-gamma effectuees sur les modeles pour les comparer aux resultats obtenus dans les conditions reelles sur le terrain. On transforme les coordonnees spatiales ainsi que les densites. Cette transformation donne la possibilite d'obtenir une courbe d'etalonnage (en fonction de la densite) pour une sonde gamma-gamma en utilisant un seul modele de densite donnee. On a etudie aussi l'influence de la composition chimique sur les resultats obtenus des mesures gamma-gamma. On a etabli une methode d'estimation du parametre Z equivalent du milieu, ainsi que la possibilite d'eliminer completement l'influence de la composition chimique du milieu sur les resultats des mesures de densite. (auteur)

  20. The performance of silicon photomultipliers in Cherenkov TOF PET

    International Nuclear Information System (INIS)

    Dolenec, Rok; Korpar, Samo; Krizan, Peter; Pestotink, Rok

    2015-01-01

    In time-of-flight positron emission tomography (TOF PET) one of the main factors limiting the time resolution is the time evolution of the scintillation process. This can be avoided by using exclusively the Cherenkov light produced in a suitable material. Sub 100 ps FWHM timing has already been experimentally demonstrated but with a drawback of relatively low detection efficiency due to the photodetectors used. In this work silicon photomultipliers (SiPMs) are considered as a photodetector in Cherenkov TOF PET. The detection efficiency can be significantly improved by using SiPMs, however, at room temperature the SiPM dark counts introduce a significant source of fake coincidences. SiPM samples from different producers were tested in a simple back-to-back setup in combination with lead fluoride Cherenkov radiators. Results for coincidence timing, detection efficiency and effects of dark counts at different temperatures and SiPM overvoltages are presented.

  1. Facility Effluent Monitoring Plan for the N Reactor

    International Nuclear Information System (INIS)

    Watson, D.J.; Brendel, D.F.; Shields, K.D.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP- 0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The primary purpose of the N Reactor Facility Effluent Monitoring Plan (FEMP), during standby, is to ensure that the radioactive effluents are properly monitored and evaluated for compliance with the applicable DOE orders and regulatory agencies at the federal, state, and local levels. A secondary purpose of the FEMP is to ensure that hazardous wastes are not released, in liquid effluents, to the environment even though the potential to do so is extremely low. The FEMP is to provide a monitoring system that collects representative samples in accordance with industry standards, performs analyses within stringent quality control (QC) requirements, and evaluates the data through the use of comparative analysis with the standards and acceptable environmental models

  2. Proteomic profiling of renal allograft rejection in serum using magnetic bead-based sample fractionation and MALDI-TOF MS.

    Science.gov (United States)

    Sui, Weiguo; Huang, Liling; Dai, Yong; Chen, Jiejing; Yan, Qiang; Huang, He

    2010-12-01

    Proteomics is one of the emerging techniques for biomarker discovery. Biomarkers can be used for early noninvasive diagnosis and prognosis of diseases and treatment efficacy evaluation. In the present study, the well-established research systems of ClinProt Micro solution incorporated unique magnetic bead sample preparation technology, which, based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), have become very successful in bioinformatics due to its outstanding performance and reproducibility for discovery disease-related biomarker. We collected fasting blood samples from patients with biopsy-confirmed acute renal allograft rejection (n = 12), chronic rejection (n = 12), stable graft function (n = 12) and also from healthy volunteers (n = 13) to study serum peptidome patterns. Specimens were purified with magnetic bead-based weak cation exchange chromatography and analyzed with a MALDI-TOF mass spectrometer. The results indicated that 18 differential peptide peaks were selected as potential biomarkers of acute renal allograft rejection, and 6 differential peptide peaks were selected as potential biomarkers of chronic rejection. A Quick Classifier Algorithm was used to set up the classification models for acute and chronic renal allograft rejection. The algorithm models recognize 82.64% of acute rejection and 98.96% of chronic rejection episodes, respectively. We were able to identify serum protein fingerprints in small sample sizes of recipients with renal allograft rejection and establish the models for diagnosis of renal allograft rejection. This preliminary study demonstrated that proteomics is an emerging tool for early diagnosis of renal allograft rejection and helps us to better understand the pathogenesis of disease process.

  3. The first neutron beam hits EAR2

    CERN Multimedia

    Antonella Del Rosso

    2014-01-01

    On 25 July 2014, about a year after construction work began, the Experimental Area 2 (EAR2) of CERN’s neutron facility n_TOF recorded its first beam. Unique in many aspects, EAR2 will start its rich programme of experimental physics this autumn.   The last part of the EAR2 beamline: the neutrons come from the underground target and reach the top of the beamline, where they hit the samples. Built about 20 metres above the neutron production target, EAR2 is in fact a bunker connected to the n_TOF underground facilities via a duct 80 cm in diameter, where the beamline is installed. The feet of the bunker support pillars are located on the concrete structure of the n_TOF tunnel and part of the structure lies above the old ISR building. A beam dump located on the roof of the building completes the structure. Neutrons are used by physicists to study neutron-induced reactions with applications in a number of fields, including nuclear waste transmutation, nuclear technology, nuclear astrop...

  4. Evaluation of a type 1 diabetes serum cohort by SELDI-TOF MS protein profiling

    DEFF Research Database (Denmark)

    Albrethsen, J.; Kaas, A.; Schonle, E.

    2009-01-01

    Proteomics analysis of serum from patients with type 1 diabetes (T1D) may lead to novel biomarkers for prediction of disease and for patient monitoring. However, the serum proteome is highly sensitive to sample processing and before proteomics biomarker research serum cohorts should preferably...... be examined for potential bias between sample groups. S ELDI-TOF MS protein profiling was used for preliminary evaluation of a biological-bank with 766 serum samples from 270 patients with T1D, collected at 18 different paediatric centers representing 15 countries in Europe and Japan over 2 years (2000......-2002). Samples collected 1 (n = 270), 6 (n = 248), and 12 (n = 248) months after T1D diagnosis were grouped across centers and compared. The serum protein profiles varied with collection site and day of analysis; however, markers of sample processing were not systematically different between samples collected...

  5. 124Xe(n,γ125Xe and 124Xe(n,2n123Xe measurements for National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Bhike Megha

    2015-01-01

    Full Text Available The cross section for the 124Xe(n,γ125Xe reaction has been measured for the first time for neutron energies above 100 keV. In addition, the 124Xe(n,2n123Xe reaction has been studied between threshold and 14.8 MeV. The results of these measurements provide sensitive diagnostic tools for investigating properties of the inertial confinement fusion plasma in Deuterium-Tritium (DT capsules at the National Ignition Facility (NIF located at Lawrence Livermore National Laboratory.

  6. Induction flowmeters for the measurement of water flow rates; Debitmetre a induction pour mesure des debits d'eau

    Energy Technology Data Exchange (ETDEWEB)

    Ailloud, J; Chandanson, P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    This article concerns a induction flow indicator used at the reactor of Chatillon for the measure of the water debits. It has two sensitivities respectively 2,5 m{sup 3}/h and 10 m{sup 3}/h to the maxima of deviation. The precision of the measures is 1 percent of the maximum of the scale. The equipment is constituted an electronic amplifier followed by a synchronous demodulator functioning to the frequency of the sector. (author) [French] L'article concerne un debitmetre a induction utilise a la Pile de Chatillon pour la mesure des debits d'eau. Il y a deux sensibilites respectivement 2,5 m{sup 3}/h et 10 m{sup 3}/h aux maxima de deviation. La precision des mesures est de 1 pour cent du maximum de l'echelle. L'appareillage est constitue d'un amplificateur electronique suivi d'un demodulateur synchrone fonctionnant a la frequence du secteur. (auteur)

  7. Molecular weight evaluation of poly-dimethylsiloxane on solid surfaces using silver deposition/TOF-SIMS

    Science.gov (United States)

    Inoue, Masae; Murase, Atsushi

    2004-06-01

    Molecular ions include information about end groups, functional groups and molecular weight. A method for directly detecting this in the high-mass region of the spectrum (>1000 amu) from poly-dimethylsiloxane (PDMS) on a solid surface was investigated. It was found that a TOF-SIMS analysis of silver-deposited surfaces (silver deposition/TOF-SIMS) is useful for this purpose. Two methods for silver deposition, the diode sputtering method and the vacuum evaporation coating method, were tried. The former required the sample to be cooled so as to prevent the damage of the sample surface due to thermal oxidation; the latter caused no damage to sample surfaces at room temperature. Using silver deposition/TOF-SIMS analysis, silver-cationized quasi-molecular ions were clearly detected from PDMS on solid surfaces and their images were observed without the interference of deposited silver. By applying to the analysis of paint defects, etc., it was confirmed that this technique is useful to analyze practical industrial materials. Silver-cationized ions were detected not only from PDMS, but also from other organic materials, such as some kinds of lubricant additives and fluorine oils on solid surfaces. Therefore, silver deposition/TOF-SIMS was proved to be useful for the analysis of thin substances on solid surfaces.

  8. Biogenic volatile organic compound analyses by PTR-TOF-MS: Calibration, humidity effect and reduced electric field dependency.

    Science.gov (United States)

    Pang, Xiaobing

    2015-06-01

    Green leaf volatiles (GLVs) emitted by plants after stress or damage induction are a major part of biogenic volatile organic compounds (BVOCs). Proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS) is a high-resolution and sensitive technique for in situ GLV analyses, while its performance is dramatically influenced by humidity, electric field, etc. In this study the influence of gas humidity and the effect of reduced field (E/N) were examined in addition to measuring calibration curves for the GLVs. Calibration curves measured for seven of the GLVs in dry air were linear, with sensitivities ranging from 5 to 10 ncps/ppbv (normalized counts per second/parts per billion by volume). The sensitivities for most GLV analyses were found to increase by between 20% and 35% when the humidity of the sample gas was raised from 0% to 70% relative humidity (RH) at 21°C, with the exception of (E)-2-hexenol. Product ion branching ratios were also affected by humidity, with the relative abundance of the protonated molecular ions and higher mass fragment ions increasing with humidity. The effect of reduced field (E/N) on the fragmentation of GLVs was examined in the drift tube of the PTR-TOF-MS. The structurally similar GLVs are acutely susceptible to fragmentation following ionization and the fragmentation patterns are highly dependent on E/N. Overall the measured fragmentation patterns contain sufficient information to permit at least partial separation and identification of the isomeric GLVs by looking at differences in their fragmentation patterns at high and low E/N. Copyright © 2015. Published by Elsevier B.V.

  9. Bayesian Peptide Peak Detection for High Resolution TOF Mass Spectrometry.

    Science.gov (United States)

    Zhang, Jianqiu; Zhou, Xiaobo; Wang, Honghui; Suffredini, Anthony; Zhang, Lin; Huang, Yufei; Wong, Stephen

    2010-11-01

    In this paper, we address the issue of peptide ion peak detection for high resolution time-of-flight (TOF) mass spectrometry (MS) data. A novel Bayesian peptide ion peak detection method is proposed for TOF data with resolution of 10 000-15 000 full width at half-maximum (FWHW). MS spectra exhibit distinct characteristics at this resolution, which are captured in a novel parametric model. Based on the proposed parametric model, a Bayesian peak detection algorithm based on Markov chain Monte Carlo (MCMC) sampling is developed. The proposed algorithm is tested on both simulated and real datasets. The results show a significant improvement in detection performance over a commonly employed method. The results also agree with expert's visual inspection. Moreover, better detection consistency is achieved across MS datasets from patients with identical pathological condition.

  10. Commissioning of the vacuum straw tracker for the COSY-TOF spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Roeder, Matthias; Ritman, James; Voigtlaender, Pierre; Wintz, Peter [Institut fuer Kernphysik I, Forschungszentrum Juelich GmbH (Germany)

    2009-07-01

    The Straw-Tracker at COSY-TOF is a system of 3120 Straws arranged in 30 layers. These are operated at 1.2 bar drift-gas pressure in the TOF vacuum so that they are self-supporting, despite their mylar wrapping being only 30 {mu}m thick. As a result the total radiation length amounts to only 1 %. The operation with 1500 V anode voltage in medium vacuum at {approx}5.10{sup -3} mbar imposes stringent demands on detector design and handling. In this talk the system is introduced and it is reported on the commissioning during the year 2008. The emphasis is placed on vacuum operation and results on the efficiency and resolution under experiment conditions.

  11. TOF MR angiography of cerebral arteriovenous malformations before and after radiotherapy

    International Nuclear Information System (INIS)

    Schlemmer, H.P.; Hess, T.; Debus, J.; Knopp, M.V.; Schad, L.R.; Engenhart, R.

    1994-01-01

    We studied whether 3D time-of-flight (TOF) MR angiography can be used for therapy planning and monitoring. MRI and TOF-MRA studies of 28 patients undergoing radiotherapy were evaluated. They were compared to conventional angiography to assess the MRA study. A correct identification of the arterial feeder and the nidus was possible in about 75% of the patients. In combination with the MRI study, an important 3D dataset for treatment planning could be obtained that includes therapeutically relevant information on the localization and spatial structure of the AVM as well as the adjacent brain tissue. As a noninvasive technique, close-meshed follow-up studies could be performed with MRA. (orig./MG) [de

  12. Data Summary Report for 116-N-1 and 116-N-3 Facility Soil Sampling to Support Remedial Design

    International Nuclear Information System (INIS)

    Ludowise, J. D.

    1999-01-01

    The 116-N-1 (1301-N) and 116-N-3 (1325-N) liquid waste disposal facilities (LWDFs) are to be remediated beginning in July 2000. Each LWDF consists of a crib and a trench. Under the proposed remedial action (DOE-RL 1998b), pipelines and above ground structures would be removed. Clean overburden material would be excavated and stockpiled. Contaminated soils would be excavated, treated (if required to meet Resource Conservation and Recovery Act of 1976 [RCRA] land disposal restrictions), and finally disposed at the Environmental Restoration Disposal Facility (ERDF). The sites would then be backfilled, graded, and revegetated. The purpose of this report is to summarize results of the sampling effort and discuss how they apply to the conceptual model of the sites and the planned remedial action under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 and closure action under RCRA

  13. Establishing MALDI-TOF as Versatile Drug Discovery Readout to Dissect the PTP1B Enzymatic Reaction.

    Science.gov (United States)

    Winter, Martin; Bretschneider, Tom; Kleiner, Carola; Ries, Robert; Hehn, Jörg P; Redemann, Norbert; Luippold, Andreas H; Bischoff, Daniel; Büttner, Frank H

    2018-07-01

    Label-free, mass spectrometric (MS) detection is an emerging technology in the field of drug discovery. Unbiased deciphering of enzymatic reactions is a proficient advantage over conventional label-based readouts suffering from compound interference and intricate generation of tailored signal mediators. Significant evolvements of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS, as well as associated liquid handling instrumentation, triggered extensive efforts in the drug discovery community to integrate the comprehensive MS readout into the high-throughput screening (HTS) portfolio. Providing speed, sensitivity, and accuracy comparable to those of conventional, label-based readouts, combined with merits of MS-based technologies, such as label-free parallelized measurement of multiple physiological components, emphasizes the advantages of MALDI-TOF for HTS approaches. Here we describe the assay development for the identification of protein tyrosine phosphatase 1B (PTP1B) inhibitors. In the context of this precious drug target, MALDI-TOF was integrated into the HTS environment and cross-compared with the well-established AlphaScreen technology. We demonstrate robust and accurate IC 50 determination with high accordance to data generated by AlphaScreen. Additionally, a tailored MALDI-TOF assay was developed to monitor compound-dependent, irreversible modification of the active cysteine of PTP1B. Overall, the presented data proves the promising perspective for the integration of MALDI-TOF into drug discovery campaigns.

  14. Limitations in SELDI-TOF MS whole serum proteomic profiling with IMAC surface to specifically detect colorectal cancer

    International Nuclear Information System (INIS)

    Wang, Qi; Gu, Jin; Shen, Jing; Li, Zhen-fu; Jie, Jian-zheng; Wang, Wen-yue; Wang, Jin; Zhang, Zhong-tao; Li, Zhi-xia; Yan, Li

    2009-01-01

    Surface enhanced laser desorption and ionization time-of-flight mass spectrometry (SELDI-TOF-MS) analysis on serum samples was reported to be able to detect colorectal cancer (CRC) from normal or control patients. We carried out a validation study of a SELDI-TOF MS approach with IMAC surface sample processing to identify CRC. A retrospective cohort of 338 serum samples including 154 CRCs, 67 control cancers and 117 non-cancerous conditions was profiled using SELDI-TOF-MS. No CRC 'specific' classifier was found. However, a classifier consisting of two protein peaks separates cancer from non-cancerous conditions with high accuracy. In this study, the SELDI-TOF-MS-based protein expression profiling approach did not perform to identify CRC. However, this technique is promising in distinguishing patients with cancer from a non-cancerous population; it may be useful for monitoring recurrence of CRC after treatment

  15. A computational platform for MALDI-TOF mass spectrometry data: application to serum and plasma samples.

    Science.gov (United States)

    Mantini, Dante; Petrucci, Francesca; Pieragostino, Damiana; Del Boccio, Piero; Sacchetta, Paolo; Candiano, Giovanni; Ghiggeri, Gian Marco; Lugaresi, Alessandra; Federici, Giorgio; Di Ilio, Carmine; Urbani, Andrea

    2010-01-03

    Mass spectrometry (MS) is becoming the gold standard for biomarker discovery. Several MS-based bioinformatics methods have been proposed for this application, but the divergence of the findings by different research groups on the same MS data suggests that the definition of a reliable method has not been achieved yet. In this work, we propose an integrated software platform, MASCAP, intended for comparative biomarker detection from MALDI-TOF MS data. MASCAP integrates denoising and feature extraction algorithms, which have already shown to provide consistent peaks across mass spectra; furthermore, it relies on statistical analysis and graphical tools to compare the results between groups. The effectiveness in mass spectrum processing is demonstrated using MALDI-TOF data, as well as SELDI-TOF data. The usefulness in detecting potential protein biomarkers is shown comparing MALDI-TOF mass spectra collected from serum and plasma samples belonging to the same clinical population. The analysis approach implemented in MASCAP may simplify biomarker detection, by assisting the recognition of proteomic expression signatures of the disease. A MATLAB implementation of the software and the data used for its validation are available at http://www.unich.it/proteomica/bioinf. (c) 2009 Elsevier B.V. All rights reserved.

  16. [Applications of MALDI-TOF-MS in clinical microbiology laboratory].

    Science.gov (United States)

    Carbonnelle, Etienne; Nassif, Xavier

    2011-10-01

    For twenty years, mass spectrometry (MS) has emerged as a particularly powerful tool for analysis and characterization of proteins in research. It is only recently that this technology, especially MALDI-TOF-MS (Matrix Assisted Laser Desorption Ionization Time-Of-Flight) has entered the field of routine microbiology. This method has proven to be reliable and safe for the identification of bacteria, yeasts, filamentous fungi and dermatophytes. MALDI-TOF-MS is a rapid, precise and cost-effective method for identification, compared to conventional phenotypic techniques or molecular biology. Its ability to analyse whole microorganisms with few sample preparation has greatly reduced the time to identification (1-2 min). Furthermore, this technology can be used to identify bacteria directly from clinical samples as blood culture bottles or urines. Future applications will be developed in order to provide direct information concerning virulence or resistance protein markers. © 2011 médecine/sciences – Inserm / SRMS.

  17. Total and (n, 2n) neutron cross section measurements on 241Am

    International Nuclear Information System (INIS)

    Sage, C.

    2009-01-01

    Neutron induced reaction cross sections on 241 Am have been measured at the IRMM in Geel, Belgium, in the frame of a collaboration between the EC Joint Research Centres IRMM and ITU and French laboratories from CNRS and CEA. Raw material coming from the Atalante facility of CEA Marcoule has been transformed into suitable AmO 2 samples embedded in Al 2 O 3 and Y 2 O 3 matrices. The irradiations for the 241 Am(n, 2n) 240 Am reaction cross section measurement were carried out at the 7 MV Van de Graaff accelerator using the activation technique with quasi mono-energetic neutrons from 8 to 21 MeV produced via the D(d, n) 3 He and the T(d, n) 4 He reactions. The cross section was determined relative to the 27 Al(n, α) 24 Na standard cross section and was investigated for the first time above 15 MeV. The induced activity was measured off-line by standard γ-ray spectrometry using a high purity Ge detector. A special effort was made for the estimation of the uncertainties and the correlations between our experimental points. A different sample of the same isotope 241 Am has been measured in transmission and capture experiments in the resolved resonance region at the neutron ToF facility GELINA. The transmission measurement was performed in two campaigns, with an upgrade of the whole data acquisition system in between, followed by an investigation of its new performances. A preliminary analysis of the resonance parameters tends to confirm the recent evaluation to a higher value for the cross section at the bottom of the first resonances. A new design of C 6 D 6 detectors for capture measurements has been studied, but the data reduction and analysis of the measurement are not part of this work. (author) [fr

  18. TOF for heavy stable particle identification

    International Nuclear Information System (INIS)

    Chang, C.Y.

    1983-01-01

    Searching for heavy stable particle production in a new energy region of hadron-hadron collisions is of fundamental theoretical interest. Observation of such particles produced in high energy collisions would indicate the existence of stable heavy leptons or any massive hadronic system carrying new quantum numbers. Experimentally, evidence of its production has not been found for PP collisions either at FNAL or at the CERN ISR for √S = 23 and 62 GeV respectively. However, many theories beyond the standard model do predict its existence on a mass scale ranging from 50 to a few hundred GeV. If so, it would make a high luminosity TeV collider an extremely ideal hunting ground for searching the production of such a speculated object. To measure the mass of a heavy stable charged particle, one usually uses its time of flight (TOF) and/or dE/dX information. For heavy neutral particle, one hopes it may decay at some later time after its production. Hence a pair of jets or a jet associated with a high P/sub t/ muon originated from some places other than the interacting point (IP) of the colliding beams may be a good signal. In this note, we examine the feasibility of TOF measurement on a heavy stable particle produced in PP collisions at √S = 1 TeV and a luminosity of 10 33 cm -2 sec -1 with a single arm spectrometer pointing to the IP

  19. Results of concentration measurements of artificial radioactive aerosols in the lower atmosphere; Resultats des mesures de concentration, dans la basse atmosphere, des aerosols radioactifs artificiels

    Energy Technology Data Exchange (ETDEWEB)

    Ardouin, B; Jehanno, C; Labeyrie, J; Lambert, G; Tanaevsky, O; Vassy, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    This report gives the results of the measurements of artificial gross-{beta}-radioactivity in aerosols in the lower atmosphere; these measurements have been made by the Electronic Physics Service of the Electronic Department, and by the Atmospheric Physics Laboratory of the Paris Science Faculty. The measurements were begun in September 1956 and were continued in an increasing number of stations both in France and in the rest of the world. The present report deals with the period up to the end of august 1961, that is up to the end of the nuclear moratorium. After recalling the constitution and the properties of radioactive aerosols present in the atmosphere, the authors describe the measurement methods, estimate their accuracy and discuss various aspects of the results. (authors) [French] Ce rapport contient les resultats des mesures de radioactivite {beta} globale d'origine artificielle des aerosols dans la basse atmosphere, effectuees conjointement par le Service d'Electronique Physique du Departement d'Electronique et le Laboratoire de Physique de l'Atmosphere de la Faculte des Sciences de Paris. Les mesures ont commence en septembre 1956 et ont ete poursuivies dans un nombre croissant de stations, tant en France que dans le reste du monde. Le present rapport s'arrete a la fin aout 1961, c'est-a-dire au moment de la reprise des essais nucleaires. Apres avoir rappele la constitution et les proprietes des aerosols radioactifs presents dans l'atmosphere, les auteurs indiquent les methodes de mesure utilisees, evaluent leur precision et discutent les differents aspects des resultats de leurs mesures. (auteurs)

  20. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF

    OpenAIRE

    Tanner, Hannah; Evans, Jason T.; Gossain, Savita; Hussain, Abid

    2017-01-01

    Background Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) w...

  1. Sequencing Lys-N Proteolytic Peptides by ESI and MALDI Tandem Mass Spectrometry

    Science.gov (United States)

    Dupré, Mathieu; Cantel, Sonia; Verdié, Pascal; Martinez, Jean; Enjalbal, Christine

    2011-02-01

    In this study, we explored the MS/MS behavior of various synthetic peptides that possess a lysine residue at the N-terminal position. These peptides were designed to mimic peptides produced upon proteolysis by the Lys-N enzyme, a metalloendopeptidase issued from a Japanese fungus Grifola frondosa that was recently investigated in proteomic studies as an alternative to trypsin digestion, as a specific cleavage at the amide X-Lys chain is obtained that provides N-terminal lysine peptide fragments. In contrast to tryptic peptides exhibiting a lysine or arginine residue solely at the C-terminal position, and are thus devoid of such basic amino acids within the sequence, these Lys-N proteolytic peptides can contain the highly basic arginine residue anywhere within the peptide chain. The fragmentation patterns of such sequences with the ESI-QqTOF and MALDI-TOF/TOF mass spectrometers commonly used in proteomic bottom-up experiments were investigated.

  2. Rapid and reliable MALDI-TOF mass spectrometry identification of Candida non-albicans isolates from bloodstream infections.

    Science.gov (United States)

    Pulcrano, Giovanna; Iula, Dora Vita; Vollaro, Antonio; Tucci, Alessandra; Cerullo, Monica; Esposito, Matilde; Rossano, Fabio; Catania, Maria Rosaria

    2013-09-01

    Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) fingerprinting has recently become an effective instrument for rapid microbiological diagnostics and in particular for identification of micro-organisms directly in a positive blood culture. The aim of the study was to evaluate a collection of 82 stored yeast isolates from bloodstream infection, by MALDI-TOF MS; 21 isolates were identified also directly from positive blood cultures and in the presence of other co-infecting micro-organisms. Of the 82 isolates grown on plates, 64 (76%) were correctly identified by the Vitek II system and 82 (100%) by MALDI-TOF MS; when the two methods gave different results, the isolate was identified by PCR. MALDI-TOF MS was unreliable in identifying two isolates (Candida glabrata and Candida parapsilosis) directly from blood culture; however, direct analysis from positive blood culture samples was fast and effective for the identification of yeast, which is of great importance for early and adequate treatment. © 2013. Published by Elsevier B.V. All rights reserved.

  3. MALDI-TOF mass spectrometry as a potential tool for Trichomonas vaginalis identification.

    Science.gov (United States)

    Calderaro, Adriana; Piergianni, Maddalena; Montecchini, Sara; Buttrini, Mirko; Piccolo, Giovanna; Rossi, Sabina; Arcangeletti, Maria Cristina; Medici, Maria Cristina; Chezzi, Carlo; De Conto, Flora

    2016-06-10

    Trichomonas vaginalis is a flagellated protozoan causing trichomoniasis, a sexually transmitted human infection, with around 276.4 million new cases estimated by World Health Organization. Culture is the gold standard method for the diagnosis of T. vaginalis infection. Recently, immunochromatographic assays as well as PCR assays for the detection of T. vaginalis antigen or DNA, respectively, have been also available. Although the well-known genome sequence of T. vaginalis has made possible the application of proteomic studies, few data are available about the overall proteomic expression profiling of T. vaginalis. The aim of this study was to investigate the potential application of MALDI-TOF MS as a new tool for the identification of T. vaginalis. Twenty-one isolates were analysed by MALDI-TOF MS after the creation of a Main Spectrum Profile (MSP) from a T. vaginalis reference strain (G3) and its subsequent supplementation in the Bruker Daltonics database, not including any profile of protozoa. This was achieved after the development of a new identification method created by modifying the range setting (6-10 kDa) for the MALDI-TOF MS analysis in order to exclude the overlapping of peaks derived from the culture media used in this study. Two MSP reference spectra were created in 2 different range: 3-15 kDa (standard range setting) and 6-10 kDa (new range setting). Both MSP spectra were deposited in the MALDI BioTyper database for further identification of additional T. vaginalis strains. All the 21 strains analysed in this study were correctly identified by using the new identification method. In this study it was demonstrated that changes in the MALDI-TOF MS standard parameters usually used to identify bacteria and fungi allowed the identification of the protozoan T. vaginalis. This study shows the usefulness of MALDI-TOF MS in the reliable identification of microorganism grown on complex liquid media such as the protozoan T. vaginalis, on the basis of the

  4. Preliminary evaluation of 3D TOF MRA fly-around advantages in the diagnosis of internal carotid artery aneurysms

    International Nuclear Information System (INIS)

    Zhu Yusen; Zhang Lina; Xu Ke; Li Songbai; Huang Yanling; Sun Wenge; Jin Anyu; Qi Xixun; Li Yanliang

    2004-01-01

    Objective: To assess the advantages and the clinical application value of 3D TOF MR angiography fly-around in diagnosing internal carotid artery aneurysms in comparison with multi-slice helical CT three dimensional angiography (MS 3D-CTA) and digital subtraction angiography (DSA). Methods: Eighteen patients with clinical suspected internal carotid artery aneurysms were involved in the study. There were 4 males and 14 females, and their age ranged from 17 to 76 years. 14 patients were with subarachnoid hemorrhage and 4 patients with oculomotor nerve palsy. All these patients underwent 3D TOF MRA and MS 3D-CTA, and 17 patients underwent DSA. All of them accepted operation treatment. 3D TOF MRA was performed with Toshiba 1.5 T MRI system and the parameters of 3D-TOF sequence were: TR 30 ms, TE 6.8 ms, field of view 17 cm x 19 cm, matrix 160 x 256, slab thickness 50-60 mm, section thickness 1.2 mm, flip angle 20 degree. Row data of MS 3D-CTA was acquired by Multi-slice helical CT-Aquilion (Toshiba). The scanning parameters were: image slice thickness 1.0 mm, scan speed 0.5 s/r, helical pitch 3.5, delay time 15-18 sec. Nonionic contrast agent was injected intravenously (2.0 ml/kg) at the speed of 4.0-5.0 ml/s using a power injector. Source images of 3D TOF MRA and MS 3D-CTA were processed into MIP and fly-around using a workstation SGI-O2, with the post-processing software Alatoview (Ver: 1.42). Conventional four-vessel digital subtraction angiography was performed with Siemens Multi-Start OT. Results: 22 aneurysms were detected by both 3D TOF MRA and MS 3D-CTA (1 ACA aneurysm, 3 ACoMA aneurysms, 1 left MCA aneurysm, 2 ICA-cavernous aneurysms, 3 left ICA-PCoM aneurysms, 8 right ICA-PCoM aneurysms, 1 left ICA-AChA aneurysms, 2 right ICA-AChA aneurysms, and 1 superior pituitary artery aneurysm). Among those aneurysms, one was not detected by DSA, and another aneurysm's neck was not clear on the image of DSA. 1 right ICA-PCoM aneurysm was surgically treated according to 3D

  5. ToF camera ego-motion estimation

    CSIR Research Space (South Africa)

    Ratshidaho, T

    2012-10-01

    Full Text Available random errors, do not have a mean value when measurements are repeated several times. They are handled by filtering. A jump edge filter is implemented in all the experiments undertaken. Jump edges occur when the transition between foreground objects... and the background objects is sudden but the camera transition is smooth. The application of a jump edge is shown in Figure 1 below. Figure 1: (a) bimodal scene used to test the jump edge filter and (b) shows the point cloud from the SR4000 ToF camera...

  6. MALDI-TOF mass spectrometry: an emerging technology for microbial identification and diagnosis.

    Science.gov (United States)

    Singhal, Neelja; Kumar, Manish; Kanaujia, Pawan K; Virdi, Jugsharan S

    2015-01-01

    Currently microorganisms are best identified using 16S rRNA and 18S rRNA gene sequencing. However, in recent years matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has emerged as a potential tool for microbial identification and diagnosis. During the MALDI-TOF MS process, microbes are identified using either intact cells or cell extracts. The process is rapid, sensitive, and economical in terms of both labor and costs involved. The technology has been readily imbibed by microbiologists who have reported usage of MALDI-TOF MS for a number of purposes like, microbial identification and strain typing, epidemiological studies, detection of biological warfare agents, detection of water- and food-borne pathogens, detection of antibiotic resistance and detection of blood and urinary tract pathogens etc. The limitation of the technology is that identification of new isolates is possible only if the spectral database contains peptide mass fingerprints of the type strains of specific genera/species/subspecies/strains. This review provides an overview of the status and recent applications of mass spectrometry for microbial identification. It also explores the usefulness of this exciting new technology for diagnosis of diseases caused by bacteria, viruses, and fungi.

  7. Noninvasive glucose sensing in scattering media using OCT, PAS, and TOF techniques

    Science.gov (United States)

    Alarousu, Erkki; Hast, Jukka T.; Kinnunen, Matti T.; Kirillin, Mikhail Y.; Myllyla, Risto A.; Plucinski, Jerzy; Popov, Alexey P.; Priezzhev, Alexander V.; Prykari, Tuukka; Saarela, Juha; Zhao, Zuomin

    2004-08-01

    In this paper, optical measurement techniques, which enable non-invasive measurement, are superimposed to glucose sensing in scattering media. Used measurement techniques are Optical Coherence Tomography (OCT), Photoacoustic spectroscopy (PAS) and laser pulse Time-of-Flight (TOF) measurement using a streak camera. In parallel with measurements, a Monte-Carlo (MC) simulation models have been developed. Experimental in vitro measurements were performed using Intralipid fat emulsion as a tissue simulating phantom for OCT and TOF measurements. In PAS measurements, a pork meat was used as a subject but also preliminary in vivo measurements were done. OCT measurement results show that the slope of the OCT signal's envelope changes as a function of glucose content in the scattering media. TOF measurements show that the laser pulse full width of half maximum (FWHM) changes a little as function of glucose content. An agreement with MC-simulations and measurements with Intralipid was also found. Measurement results of PAS technique show that changes in glucose content in the pork meat tissue can be measured. In vivo measurements with a human volunteer show that other factors such as physiological change, blood circulation and body temperature drift may interfere the PA response of glucose.

  8. Application of targeted quantitative proteomics analysis in human cerebrospinal fluid using a liquid chromatography matrix-assisted laser desorption/ionization time-of-flight tandem mass spectrometer (LC MALDI TOF/TOF) platform.

    Science.gov (United States)

    Pan, Sheng; Rush, John; Peskind, Elaine R; Galasko, Douglas; Chung, Kathryn; Quinn, Joseph; Jankovic, Joseph; Leverenz, James B; Zabetian, Cyrus; Pan, Catherine; Wang, Yan; Oh, Jung Hun; Gao, Jean; Zhang, Jianpeng; Montine, Thomas; Zhang, Jing

    2008-02-01

    Targeted quantitative proteomics by mass spectrometry aims to selectively detect one or a panel of peptides/proteins in a complex sample and is particularly appealing for novel biomarker verification/validation because it does not require specific antibodies. Here, we demonstrated the application of targeted quantitative proteomics in searching, identifying, and quantifying selected peptides in human cerebrospinal spinal fluid (CSF) using a matrix-assisted laser desorption/ionization time-of-flight tandem mass spectrometer (MALDI TOF/TOF)-based platform. The approach involved two major components: the use of isotopic-labeled synthetic peptides as references for targeted identification and quantification and a highly selective mass spectrometric analysis based on the unique characteristics of the MALDI instrument. The platform provides high confidence for targeted peptide detection in a complex system and can potentially be developed into a high-throughput system. Using the liquid chromatography (LC) MALDI TOF/TOF platform and the complementary identification strategy, we were able to selectively identify and quantify a panel of targeted peptides in the whole proteome of CSF without prior depletion of abundant proteins. The effectiveness and robustness of the approach associated with different sample complexity, sample preparation strategies, as well as mass spectrometric quantification were evaluated. Other issues related to chromatography separation and the feasibility for high-throughput analysis were also discussed. Finally, we applied targeted quantitative proteomics to analyze a subset of previously identified candidate markers in CSF samples of patients with Parkinson's disease (PD) at different stages and Alzheimer's disease (AD) along with normal controls.

  9. Total cross-section measurements on aluminium, carbon, fluorine and hydrogen for d, d reaction neutrons using the coincidence method (1963); Mesure de la section efficace totale de l'aluminium, du carbone, du fluor et de l'hydrogene pour des neutrons de la reaction d, d par la methode des coincidences (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosino, G; Sorriaux, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The experiment described consists in the measurement of the total cross-section of various materials: aluminium, carbon, fluorine and hydrogen, for mono-energetic 2.77 MeV neutrons obtained from the d,d reaction. The measurement is carried out by transmission. The neutrons are detected by means of a plastic scintillator mounted on a 56 AVP photomultiplier, and are isolated from all secondary phenomena (background noise, scattered neutrons) by coincidence with helium 3. which particles are associated to the neutrons from the reaction {sup 2}{sub 1}D ({sup 2}{sub 1}D, n) {sup 3}{sub 2}H The helium 3 particles are detected by a PN junction diode used with inverted polarisation. An absorption exponential has been traced out using measurements made on seven aluminium bars. The accuracy of the total cross-section measurements is about 10{sup -2}. (authors) [French] L'experience exposee dans ce rapport consiste en la mesure des sections efficaces totales de differents materiaux: aluminium, carbone, fluor et hydrogene, pour des neutrons monoenergetiques de 2,77 MeV, obtenus par la reaction d,d. La mesure est faite par transmission. Les neutrons sont detectes par un scintillateur plastique monte sur un photomultiplicateur 56 AVP, et sont separes de tout phenomene secondaire (bruit de fond, neutrons diffuses) par coincidence avec les helium 3, particules associees aux neutrons de la reaction {sup 2}{sub 1}D ({sup 2}{sub 1}D, n) {sup 3}{sub 2}H Les helium 3 sont detectes par une diode a jonction PN utilisee en polarisation inverse. Une exponentielle d'absorption a ete tracee a partir de mesures faites sur sept barreaux d'aluminium. La precision des mesures des sections efficaces totales est de l'ordre de 10{sup -2}. (auteurs)

  10. MALDI-TOF mass spectrometry for differentiation between Streptococcus pneumoniae and Streptococcus pseudopneumoniae.

    Science.gov (United States)

    van Prehn, Joffrey; van Veen, Suzanne Q; Schelfaut, Jacqueline J G; Wessels, Els

    2016-05-01

    We compared the Vitek MS and Microflex MALDI-TOF mass spectrometry platform for species differentiation within the Streptococcus mitis group with PCR assays targeted at lytA, Spn9802, and recA as reference standard. The Vitek MS correctly identified 10/11 Streptococcus pneumoniae, 13/13 Streptococcus pseudopneumoniae, and 12/13 S. mitis/oralis. The Microflex correctly identified 9/11 S. pneumoniae, 0/13 S. pseudopneumoniae, and 13/13 S. mitis/oralis. MALDI-TOF is a powerful tool for species determination within the mitis group. Diagnostic accuracy varies depending on platform and database used. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Création d'outils pour la mesure de l'intégration des technologies de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    En collaborant avec les ministères de l'Éducation de la Colombie, du Mexique, du Pérou et de l'Uruguay, les chercheurs élaboreront des méthodologies communes et des indicateurs pertinents localement en vue de surveiller et de mesurer l'intégration des TIC en classe. Les résultats obtenus fourniront aux décideurs les ...

  12. KEK-IMSS Slow Positron Facility

    Energy Technology Data Exchange (ETDEWEB)

    Hyodo, T; Wada, K; Yagishita, A; Kosuge, T; Saito, Y; Kurihara, T; Kikuchi, T; Shirakawa, A; Sanami, T; Ikeda, M; Ohsawa, S; Kakihara, K; Shidara, T, E-mail: toshio.hyodo@kek.jp [High Energy Accelerator Research Organization (KEK) 1-1 Oho, Tsukuba, Ibaraki, 305-0801 (Japan)

    2011-12-01

    The Slow Positron Facility at the Institute of Material Structure Science (IMSS) of High Energy Accelerator Research Organization (KEK) is a user dedicated facility with an energy tunable (0.1 - 35 keV) slow positron beam produced by a dedicated 55MeV linac. The present beam line branches have been used for the positronium time-of-flight (Ps-TOF) measurements, the transmission positron microscope (TPM) and the photo-detachment of Ps negative ions (Ps{sup -}). During the year 2010, a reflection high-energy positron diffraction (RHEPD) measurement station is going to be installed. The slow positron generator (converter/ moderator) system will be modified to get a higher slow positron intensity, and a new user-friendly beam line power-supply control and vacuum monitoring system is being developed. Another plan for this year is the transfer of a {sup 22}Na-based slow positron beam from RIKEN. This machine will be used for the continuous slow positron beam applications and for the orientation training of those who are interested in beginning researches with a slow positron beam.

  13. Concentration urinaire de bisphénol A et obésité chez les adultes : résultats de l’Enquête canadienne sur les mesures de la santé

    Directory of Open Access Journals (Sweden)

    Minh T. Do

    2017-01-01

    ée au tour de taille pour les valeurs seuils courantes. Enfin, chaque unité d’augmentation du log naturel de la concentration urinaire de BPA a été associée à une hausse de 0,33 kg/m2 (IC à 95 % : 0,10 à 0,57 de l’IMC et de 1,00 cm (IC à 95 % : 0,34 à 1,65 du tour de taille. Conclusion : Notre étude vient enrichir le corpus croissant de données probantes sur l’association positive entre BPA et obésité. Des études prospectives comportant un suivi de mesures sont nécessaires pour définir la dimension temporelle de l’association et améliorer la classification de l’exposition.

  14. Combined use of ESI-QqTOF-MS and ESI-QqTOF-MS/MS with mass-spectral library search for qualitative analysis of drugs.

    Science.gov (United States)

    Pavlic, Marion; Libiseller, Kathrin; Oberacher, Herbert

    2006-09-01

    The potential of the combined use of ESI-QqTOF-MS and ESI-QqTOF-MS/MS with mass-spectral library search for the identification of therapeutic and illicit drugs has been evaluated. Reserpine was used for standardizing experimental conditions and for characterization of the performance of the applied mass spectrometric system. Experiments revealed that because of the mass accuracy, the stability of calibration, and the reproducibility of fragmentation, the QqTOF mass spectrometer is an appropriate platform for establishment of a tandem-mass-spectral library. Three-hundred and nineteen substances were used as reference samples to build the spectral library. For each reference compound, product-ion spectra were acquired at ten different collision-energy values between 5 eV and 50 eV. For identification of unknown compounds, a library search algorithm was developed. The closeness of matching between a measured product-ion spectrum and a spectrum stored in the library was characterized by a value called "match probability", which took into account the number of matched fragment ions, the number of fragment ions observed in the two spectra, and the sum of the intensity differences calculated for matching fragments. A large value for the match probability indicated a close match between the measured and the reference spectrum. A unique feature of the library search algorithm-an implemented spectral purification option-enables characterization of multi-contributor fragment-ion spectra. With the aid of this software feature, substances comprising only 1.0% of the total amount of binary mixtures were unequivocally assigned, in addition to the isobaric main contributors. The spectral library was successfully applied to the characterization of 39 forensic casework samples.

  15. Screening natural antioxidants in peanut shell using DPPH-HPLC-DAD-TOF/MS methods.

    Science.gov (United States)

    Qiu, Jiying; Chen, Leilei; Zhu, Qingjun; Wang, Daijie; Wang, Wenliang; Sun, Xin; Liu, Xiaoyong; Du, Fangling

    2012-12-15

    Peanut shell, a byproduct in oil production, is rich in natural antioxidants. Here, a rapid and efficient method using DPPH-HPLC-DAD-TOF/MS was used for the first time to screen antioxidants in peanut shell. The method is based on the hypothesis that upon reaction with 1, 1-diphenyl-2-picrylhydrazyl (DPPH), the peak areas of compounds with potential antioxidant activities in the HPLC chromatogram will be significantly reduced or disappeared, and the identity confirmation could be achieved by HPLC-DAD-TOF/MS technique. With this method, three compounds possessing potential antioxidant activities were found abundantly in the methanolic extract of peanut shell. They were identified as 5,7-dihydroxychromone, eriodictyol, and luteolin. The contents of these compounds were 0.59, 0.92, and 2.36 mg/g, respectively, and luteolin possessed the strongest radical scavenging capacity. DPPH-HPLC-DAD-TOF/MS assay facilitated rapid identification and determination of natural antioxidants in peanut shell, which may be helpful for value-added utilization of peanut processing byproducts. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF.

    Science.gov (United States)

    Tanner, Hannah; Evans, Jason T; Gossain, Savita; Hussain, Abid

    2017-01-18

    Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) were applied to each positive culture followed by centrifugation, washing and protein extraction steps. Methods were compared using the McNemar test and 16S rDNA sequencing was used to assess discordant results. In 144 monomicrobial cultures, using ≥2.000 as the cut-off value, species level identifications were obtained from 69/144 (48%) samples using Saponin, 86/144 (60%) using SDS, and 91/144 (63%) using SepsiTyper. The difference between SDS and SepsiTyper was not statistically significant (P = 0.228). Differences between Saponin and the other two reagents were significant (P direct MALDI-TOF identification were observed in monomicrobial cultures. In 32 polymicrobial cultures, MALDI-TOF identified one organism in 34-75% of samples depending on the method. This study demonstrates two inexpensive in-house detergent lysis methods are non-inferior to a commercial kit for analysis of positive blood cultures by direct MALDI-TOF in a clinical diagnostic microbiology laboratory.

  17. Deuterium-tritium neutron yield measurements with the 4.5 m neutron-time-of-flight detectors at NIF.

    Science.gov (United States)

    Moran, M J; Bond, E J; Clancy, T J; Eckart, M J; Khater, H Y; Glebov, V Yu

    2012-10-01

    The first several campaigns of laser fusion experiments at the National Ignition Facility (NIF) included a family of high-sensitivity scintillator∕photodetector neutron-time-of-flight (nTOF) detectors for measuring deuterium-deuterium (DD) and DT neutron yields. The detectors provided consistent neutron yield (Y(n)) measurements from below 10(9) (DD) to nearly 10(15) (DT). The detectors initially demonstrated detector-to-detector Y(n) precisions better than 5%, but lacked in situ absolute calibrations. Recent experiments at NIF now have provided in situ DT yield calibration data that establish the absolute sensitivity of the 4.5 m differential tissue harmonic imaging (DTHI) detector with an accuracy of ± 10% and precision of ± 1%. The 4.5 m nTOF calibration measurements also have helped to establish improved detector impulse response functions and data analysis methods, which have contributed to improving the accuracy of the Y(n) measurements. These advances have also helped to extend the usefulness of nTOF measurements of ion temperature and downscattered neutron ratio (neutron yield 10-12 MeV divided by yield 13-15 MeV) with other nTOF detectors.

  18. Applications of MALDI-TOF MS in Microbiological identification

    Directory of Open Access Journals (Sweden)

    Soner Yilmaz

    2014-10-01

    Full Text Available MALDI-TOF MS (Matriks assisted laser desorption ionization time of flight mass spectrometry is a new metohod for identification of microorganisms nowadays. This method is based revealing of microorganisms protein profile with ionization of protein structure and these ionized mass pass through the electrical field. Profiles which were obtained from microorganisms compare with database of system thus identification is made by this way. Ribosomal proteins are used in identification which are less affected by enviromental conditions. Fresh culture should preferably use in MALDI-TOF MS identification. Ribosomal proteins can be deteriorate in old cultures. The correct identification rates are changing between 84,1% to 95,2% in routine bacterial isolates. The correct identification rates in yeasts are changing between 85% to 100%. It makes identification in positive blood culture bottles without the need of subculture, also makes identification on urine samples without the need of culture which has greater than 105 microorganisms in a microliter. When it compared with conventional and molecular identification methods, it is more effective on per sample costs and elapsed time on working [TAF Prev Med Bull 2014; 13(5.000: 421-426

  19. The origin and reduction of spurious extrahepatic counts observed in 90Y non-TOF PET imaging post radioembolization

    Science.gov (United States)

    Walrand, Stephan; Hesse, Michel; Jamar, François; Lhommel, Renaud

    2018-04-01

    Our literature survey revealed a physical effect unknown to the nuclear medicine community, i.e. internal bremsstrahlung emission, and also the existence of long energy resolution tails in crystal scintillation. None of these effects has ever been modelled in PET Monte Carlo (MC) simulations. This study investigates whether these two effects could be at the origin of two unexplained observations in 90Y imaging by PET: the increasing tails in the radial profile of true coincidences, and the presence of spurious extrahepatic counts post radioembolization in non-TOF PET and their absence in TOF PET. These spurious extrahepatic counts hamper the microsphere delivery check in liver radioembolization. An acquisition of a 32P vial was performed on a GSO PET system. This is the ideal setup to study the impact of bremsstrahlung x-rays on the true coincidence rate when no positron emission and no crystal radioactivity are present. A MC simulation of the acquisition was performed using Gate-Geant4. MC simulations of non-TOF PET and TOF-PET imaging of a synthetic 90Y human liver radioembolization phantom were also performed. Internal bremsstrahlung and long energy resolution tails inclusion in MC simulations quantitatively predict the increasing tails in the radial profile. In addition, internal bremsstrahlung explains the discrepancy previously observed in bremsstrahlung SPECT between the measure of the 90Y bremsstrahlung spectrum and its simulation with Gate-Geant4. However the spurious extrahepatic counts in non-TOF PET mainly result from the failure of conventional random correction methods in such low count rate studies and poor robustness versus emission-transmission inconsistency. A novel proposed random correction method succeeds in cleaning the spurious extrahepatic counts in non-TOF PET. Two physical effects not considered up to now in nuclear medicine were identified to be at the origin of the unusual 90Y true coincidences radial profile. TOF reconstruction removing

  20. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, C. J., E-mail: cjwaugh@mit.edu; Zylstra, A. B.; Frenje, J. A.; Séguin, F. H.; Petrasso, R. D. [Plasma Science and Fusion Center, MIT, Cambridge, Massachusetts 02139 (United States); Rosenberg, M. J.; Glebov, V. Yu.; Sangster, T. C.; Stoeckl, C. [Laboratory for Laser Energetics, Rochester, New York 14623 (United States)

    2015-05-15

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

  1. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors.

    Science.gov (United States)

    Waugh, C J; Rosenberg, M J; Zylstra, A B; Frenje, J A; Séguin, F H; Petrasso, R D; Glebov, V Yu; Sangster, T C; Stoeckl, C

    2015-05-01

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

  2. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors

    International Nuclear Information System (INIS)

    Waugh, C. J.; Zylstra, A. B.; Frenje, J. A.; Séguin, F. H.; Petrasso, R. D.; Rosenberg, M. J.; Glebov, V. Yu.; Sangster, T. C.; Stoeckl, C.

    2015-01-01

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule

  3. Description of work vadose drilling at the 1301-N and 1325-N facilities, 100-NR-1 operable unit

    International Nuclear Information System (INIS)

    1994-08-01

    This description of work (DOW) details the field activities associated with the sampling of the vadose zone soils beneath the 1301-N and 1325-N cribs and trenches and will serve as a field guide for those performing the work. These activities are undertaken pursuant to the Hanford Federal Facility Agreement and Consent Order (Ecology et al., 1994a) Milestone M-16-94-01H-Tl and the June 30, 1994 Milestone Change Request M-16-94-02 (Ecology et al., 1994b). Three vadose zone borings, 1301-N-1, 1301-N-2, and 1325-N-1, will be constructed to investigate the vertical and horizontal distribution of radionuclide contamination in sediments beneath the cribs and trenches. The boreholes are also intended to intersect subsurface areas that may have been contaminated by dangerous wastes, i.e., metals, in effluent disposed during past operation of the facilities. This limited field investigation will provide data for the evaluation of remedial alternatives. Data from the investigation are expected to confirm that the cribs and trenches are high priority sites in the 100-NR-1 operable unit. Data, from the investigation will be used to evaluate alternatives for closure of the 1301-N and 1325-N sites. The contaminants of potential concern (COPCs) for the 1301-N/1325-N limited field investigation are presented in Table 1

  4. Characterization of Novel Fusaricidins Produced by Paenibacillus polymyxa-M1 Using MALDI-TOF Mass Spectrometry

    Science.gov (United States)

    Vater, Joachim; Niu, Ben; Dietel, Kristin; Borriss, Rainer

    2015-09-01

    Paenibacillus polymyxa-M1 is a potent producer of bioactive compounds, such as lipopeptides, polyketides, and lantibiotics of biotechnological and medical interest. Genome sequencing revealed nine gene clusters for nonribosomal biosynthesis of such agents. Here we report on the investigation of the fusaricidins, a complex of cyclic lipopeptides containing 15-guanidino-3-hydroxypentadecanoic acid (GHPD) as fatty acid component by matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). More than 20 variants of these compounds were detected and characterized in detail. Mass spectrometric sequence analysis was performed by MALDI-LIFT-TOF/TOF fragment analysis. The obtained product ion spectra show a specific processing in the fatty acid part. GHPD is cleaved between the α- and ß-position yielding two fragments a and b, one bearing the end-standing guanidine group and another one comprising the residual two C-atoms of GHPD with the attached peptide moiety. The complete sequence of all fusaricidins was derived from sets of bn- and yn-ions. The fusaricidin complex can be divided into four lipopeptide families, three of them showing variations of the amino acid in position 3, Val or Ile for the first and Tyr or Phe for families 2 and 3, respectively. A collection of novel fusaricidins was detected differing from those of families 1-3 by an additional residue of 71 Da (family 4). LIFT-TOF/TOF fragment spectra of these species imply that in their peptide moiety, an Ala-residue is attached by an ester bond to the free hydroxyl group of Thr4. More than 10 novel fusaricidins were characterized mass spectrometrically.

  5. Detection and identification of bio-threats using MALDI-TOF-MS

    NARCIS (Netherlands)

    Paauw, A.

    2012-01-01

    MALDI-TOF-MS emerged as a new diagnostic tool in established clinical laboratories. Advantages compared to conventional techniques are that it is a fast, cost-effective, accurate method, which is suitable for high-throughput identification of bacteria by less skilled laboratory personnel because

  6. Gestion génétique des populations naturelles de poissons

    Directory of Open Access Journals (Sweden)

    1989-07-01

    Il propose un ertain nombre de mesures simples permettant de conserver pendant un période relativement longue (20 à 30 ans des populations produisants des sujets de repeuplement "génétiquement proches" des individus sauvages de la population d'origine.

  7. A simple and effective method for detecting precipitated proteins in MALDI-TOF MS.

    Science.gov (United States)

    Oshikane, Hiroyuki; Watabe, Masahiko; Nakaki, Toshio

    2018-04-01

    MALDI-TOF MS has developed rapidly into an essential analytical tool for the life sciences. Cinnamic acid derivatives are generally employed in routine molecular weight determinations of intact proteins using MALDI-TOF MS. However, a protein of interest may precipitate when mixed with matrix solution, perhaps preventing MS detection. We herein provide a simple approach to enable the MS detection of such precipitated protein species by means of a "direct deposition method" -- loading the precipitant directly onto the sample plate. It is thus expected to improve routine MS analysis of intact proteins. Copyright © 2018. Published by Elsevier Inc.

  8. Results and interpretation of spectral indices measurements made with AQUILON; Resultats et interpretation de mesures d'indices de spectre dans aquilon

    Energy Technology Data Exchange (ETDEWEB)

    Frichet, J P; Mougey, J N; Naudet, R; Taste, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    This report deals with a set of spectral indices measurements made in the heavy water reactor Aquilon on lattices constituted by massive fuel elements of dia. 29,2 mm. The fuel elements were made either of natural uranium or of slightly depleted or slightly enriched uranium, or of an uranium-plutonium alloy. The measurements were carried out for various lattice pitches (square pitch from 110 to 210 mm) and in certain cases for various temperatures (from 20 to 80 deg. C). The results are compared to calculated values obtained by using the latest advances of the thermalization theory developed at Saclay applied to the moderation by heavy water. (authors) [French] Ce rapport est consacre a un ensemble de mesures d'indices de spectre realisees dans la pile a eau lourde Aquilon sur des reseaux d'elements combustibles pleins, de 29,2 mm de diametre. Ces combustibles se composaient ou bien d'uranium naturel, ou bien d'uranium tres legerement appauvri ou enrichi, ou bien d'un alliage uranium plutonium. Les mesures ont ete effectuees pour toute une serie de pas de reseaux (pas carre 110 a 210 mm), certaines d'entre elles a plusieurs temperatures (20 a 80 deg. C). Les resultats des mesures sont compares a des valeurs calculees obtenues en utilisant les plus recents developpements de la theorie de la thermalisation mise au point a Saclay, appliques au cas de la moderation par l'eau lourde. (auteurs)

  9. Les déchets électroniques et informatiques en Afrique: Défis et ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Les recherches scientifiques nous permettent de mieux mesurer les risques et de ... Ils servent de cadre mou, donc hélas facilement « négociable », à la gestion des .... Direction nationale du Contrôle des Pollutions et des Nuisances. DNSI .... de profit et de performance, les produits informatiques et électroniques voient leur ...

  10. N-glycosylation of colorectal cancer tissues: a liquid chromatography and mass spectrometry-based investigation.

    Science.gov (United States)

    Balog, Crina I A; Stavenhagen, Kathrin; Fung, Wesley L J; Koeleman, Carolien A; McDonnell, Liam A; Verhoeven, Aswin; Mesker, Wilma E; Tollenaar, Rob A E M; Deelder, André M; Wuhrer, Manfred

    2012-09-01

    Colorectal cancer is the third most common cancer worldwide with an annual incidence of ~1 million cases and an annual mortality rate of ~655,000 individuals. There is an urgent need for identifying novel targets to develop more sensitive, reliable, and specific tests for early stage detection of colon cancer. Post-translational modifications are known to play an important role in cancer progression and immune surveillance of tumors. In the present study, we compared the N-glycan profiles from 13 colorectal cancer tumor tissues and corresponding control colon tissues. The N-glycans were enzymatically released, purified, and labeled with 2-aminobenzoic acid. Aliquots were profiled by hydrophilic interaction liquid chromatography (HILIC-HPLC) with fluorescence detection and by negative mode MALDI-TOF-MS. Using partial least squares discriminant analysis to investigate the N-glycosylation changes in colorectal cancer, an excellent separation and prediction ability were observed for both HILIC-HPLC and MALDI-TOF-MS data. For structure elucidation, information from positive mode ESI-ion trap-MS/MS and negative mode MALDI-TOF/TOF-MS was combined. Among the features with a high separation power, structures containing a bisecting GlcNAc were found to be decreased in the tumor, whereas sulfated glycans, paucimannosidic glycans, and glycans containing a sialylated Lewis type epitope were shown to be increased in tumor tissues. In addition, core-fucosylated high mannose N-glycans were detected in tumor samples. In conclusion, the combination of HILIC and MALDI-TOF-MS profiling of N-glycans with multivariate statistical analysis demonstrated its potential for identifying N-glycosylation changes in colorectal cancer tissues and provided new leads that might be used as candidate biomarkers.

  11. L'état de l'environnement industriel français est-il objectivement mesurable ?

    OpenAIRE

    Gotteland, David; Boulé, Jean-Marie

    2004-01-01

    Working paper serie RMT (WPS 04-07); the environmental state is a frequently modelized variable in marketing research. This paper proposes updated scales and panorama of the objective state of 58 industrial branches defined by INSEE based on three characteristic dimensions: dynamism, complexity and capacity.; l'état de l'environnement est une variable fréquemment modélisée dans la recherche en marketing. A partir de ce constat, cet article propose une échelle de mesure et un panorama actualis...

  12. Validation of Cross Sections with Criticality Experiment and Reaction Rates: the Neptunium Case

    CERN Document Server

    Leong, L S; Audouin, L; Berthier, B; Le Naour, C; Stéphan, C; Paradela, C; Tarrío, D; Duran, I

    2014-01-01

    The Np-237 neutron-induced fission cross section has been recently measured in a large energy range (from eV to GeV) at the n\\_TOF facility at CERN. When compared to previous measurements the n\\_TOF fission cross section appears to be higher by 5-7\\% beyond the fission threshold. To check the relevance of the n\\_TOF data, we considered a criticality experiment performed at Los Alamos with a 6 kg sphere of Np-237, surrounded by uranium highly enriched in U-235 so as to approach criticality with fast neutrons. The multiplication factor k(eff) of the calculation is in better agreement with the experiment when we replace the ENDF/B-VII. 0 evaluation of the Np-237 fission cross section by the n\\_TOF data. We also explored the hypothesis of deficiencies of the inelastic cross section in U-235 which has been invoked by some authors to explain the deviation of 750 pcm. The large modification needed to reduce the deviation seems to be incompatible with existing inelastic cross section measurements. Also we show that t...

  13. Mesures de spectrométrie et de dosimétrie neutron aux postes de travail pour l'étalonnage de dosimètres individuels PGP-DIN

    OpenAIRE

    Itié, C.; Muller, H.; Asselineau, B.; Médioni, R.; Crovisier, P.; Valier-Bradier, P.; Groetz, J. E.; Piot, J.

    2002-01-01

    International audience; (ManuAcrit r e p le 3 juillet 2002, accepté le 29 septembre 2002) Dans le cadre de la mise en application des recommandations décrites dans la publication 60 de la CIPR, des mesures de spectrométrie neutron ont été réalisées à plusieurs postes de travail au CEA de Valduc. Le but de ces mesures était la détermination de nouveaux coefficients d'étalonnage h affecter aux dosimètres individuels neutron PGP-DIN afin de restituer correctement les doses reçues par les opérate...

  14. InN{0001} polarity by ion scattering spectroscopy

    International Nuclear Information System (INIS)

    Walker, M.; Veal, T.D.; McConville, C.F.; Lu, Hai; Schaff, W.J.

    2005-01-01

    The polarity of a wurtzite InN thin film grown on a c-plane sapphire substrate with GaN and AlN buffer layers has been investigated by co-axial impact collision ion scattering spectroscopy (CAICISS). Time of flight (TOF) spectra of He + ions scattered from the surface of the InN film were taken as a function of the incident angles of the primary 3 keV He + ions. From the TOF spectra, the polar angle-dependence of the In scattered intensity was obtained. Comparison of the experimental polar-angle dependence of the In CAICISS signal intensity with simulated results for the various volume ratios of (0001)- and (000 anti 1)-polarity domains indicated that the InN film is approximately 75% In-polarity and 25% N-polarity. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  15. Hexose rearrangements upon fragmentation of N-glycopeptides and reductively aminated N-glycans.

    Science.gov (United States)

    Wuhrer, Manfred; Koeleman, Carolien A M; Deelder, André M

    2009-06-01

    Tandem mass spectrometry of glycans and glycoconjugates in protonated form is known to result in rearrangement reactions leading to internal residue loss. Here we studied the occurrence of hexose rearrangements in tandem mass spectrometry of N-glycopeptides and reductively aminated N-glycans by MALDI-TOF/TOF-MS/MS and ESI-ion trap-MS/MS. Fragmentation of proton adducts of oligomannosidic N-glycans of ribonuclease B that were labeled with 2-aminobenzamide and 2-aminobenzoic acid resulted in transfer of one to five hexose residues to the fluorescently tagged innermost N-acetylglucosamine. Glycopeptides from various biological sources with oligomannosidic glycans were likewise shown to undergo hexose rearrangement reactions, resulting in chitobiose cleavage products that have acquired one or two hexose moieties. Tryptic immunoglobulin G Fc-glycopeptides with biantennary N-glycans likewise showed hexose rearrangements resulting in hexose transfer to the peptide moiety retaining the innermost N-acetylglucosamine. Thus, as a general phenomenon, tandem mass spectrometry of reductively aminated glycans as well as glycopeptides may result in hexose rearrangements. This characteristic of glycopeptide MS/MS has to be considered when developing tools for de novo glycopeptide structural analysis.

  16. Physical properties of the TOF (time of flight) scintillation counters of DELPHI

    International Nuclear Information System (INIS)

    Benlloch, J.M.; Castillo, M.V.; Ferrer, A.; Fuster, J.; Higon, E.; Llopis, A.; Salt, J.; Sanchez, E.; Sanchis, E.; Silvestre, E.; Cuevas, J.

    1990-01-01

    In this paper we report the physical properties of the time of flight (TOF) scintillator counters used for the DELPHI Experiment at CERN. We discuss the different choices studied for the wrapping of the counters in order to obtain best efficiencies for light transmission. A very good agreement of the performances of the counters has been found with the results of an original Monte Carlo program. The main characteristics of the TOF counters of DELPHI are: an effective light attenuation length of 135 cm, effective light speed of 15.91 cm/ns, a time resolution of 1.2 ns, and an efficiency for detection of minimum ionizing particles of 99.9%. (orig.)

  17. R and D of the Endcap TOF detector for BES III

    International Nuclear Information System (INIS)

    Tang Zebo; Li Xin; An Shaohui; Chen Hongfang; Li Cheng; Shao Ming; Sun Yongjie; Zeng Hui; Zhao Li; Heng Yuekun; Wang Yifang; Wu Chong; Zhao Xiaojian

    2006-01-01

    The Endcap TOF (ETOF) of Beijing Spectrometer (BES III) is consisted of 2 x 48 pieces of trapezoidal scintillator. Its main physics goal is to realize 2σ π/k separation at momentum up to 0.8 GeV/c, and to reach the intrinsic time resolution of 80 ps. The properties of photomultiplier tube (R5924) and plastic scintillators (BC404, BC408, EJ204) are studied, a ETOF module with different wrappings is tested with the beam of 800 MeV electron at IHEP. The results show that the time resolution of an ETOF module using scintillator BC404 or EJ204 is below 80 ps which includes the electronic fluctuation. The ESR wrapping can efficiently enhance the amplitude of the output pulse and improve the performance of the TOF detector. (authors)

  18. Experimental measurement of fission fragments paths in uranium gold, molybdenum, zirconium and silicon; Mesure experimentale des parcours des fragments de fission dans l'uranium, l'or, le molybdene, le zirconium et le silicium

    Energy Technology Data Exchange (ETDEWEB)

    Faraggi, H; Garin-Bonnet, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The measurement of total number of fissiongments emerging from an homogeneous, thick alloy composed of uranium plus another element (the concentration of uranium being known) allows to obtain the range of the fragments in this alloy. By varying the concentration, the range of the fragments in uranium and in the other element can be deduced. (author)Fren. [French] La mesure du nombre total de fragments de fission sortant d'un alliage homogene epais d'uranium et d'un autre element, pour lequel la concentration en uranium est donnee, permet la mesure du parcours des fragments dans cet alliage. En faisant varier la concentration, on peut deduire de ces mesures le parcours des fragments dans l'uranium et dans l'autre element. (auteur)

  19. Characterization of Bacteria in Ballast Water Using MALDI-TOF Mass Spectrometry

    Digital Repository Service at National Institute of Oceanography (India)

    Emami, K.; Askari, V.; Ullrich, M.; Mohinudeen, K.; Anil, A.C.; Khandeparker, L.; Burgess, J.G.; Mesbahi, E.

    To evaluate a rapid and cost-effective method for monitoring bacteria in ballast water, several marine bacterial isolates were characterized by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). Since...

  20. Bactec™ blood culture bottles allied to MALDI-TOF mass spectrometry: rapid etiologic diagnosis of bacterial endophthalmitis.

    Science.gov (United States)

    Tanaka, Tatiana; Oliveira, Luiza Manhezi de Freitas; Ferreira, Bruno Fortaleza de Aquino; Kato, Juliana Mika; Rossi, Flavia; Correa, Karoline de Lemes Giuntini; Pimentel, Sergio Luis Gianotti; Yamamoto, Joyce Hisae; Almeida Junior, João Nóbrega

    2017-07-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) has been used for direct identification of pathogens from blood-inoculated blood culture bottles (BCBs). We showed that MALDI-TOF MS is an useful technique for rapid identification of the causative agents of endophthalmitis from vitreous humor-inoculated BCBs with a simple protocol. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. A CD45-based barcoding approach to multiplex mass-cytometry (CyTOF).

    Science.gov (United States)

    Lai, Liyun; Ong, Raymond; Li, Juntao; Albani, Salvatore

    2015-04-01

    CyTOF enables the study of the immune system with a complexity, depth, and multidimensionality never achieved before. However, the full potential of using CyTOF can be limited by scarce cell samples. Barcoding strategies developed based on direct labeling of cells using maleimido-monoamide-DOTA (m-DOTA) provide a very useful tool. However, using m-DOTA has some inherent problems, mainly associated with signal intensity. This may be a source of uncertainty when samples are multiplexed. As an alternative or complementary approach to m-DOTA, conjugating an antibody, specific for a membrane protein present on most immune cells, with different isotopes could address the issues of stability and signal intensity needed for effective barcoding. We chose for this purpose CD45, and designed experiments to address different types of cultures and the ability to detect extra- and intra-cellular targets. We show here that our approach provides an useful alternative to m-DOTA in terms of sensitivity, specificity, flexibility, and user-friendliness. Our manuscript provides details to effectively barcode immune cells, overcoming limitations in current technology and enabling the use of CyTOF with scarce samples (for instance precious clinical samples). © 2015 The Authors. Published by Wiley Periodicals, Inc.

  2. The optimization and validation of the Biotyper MALDI-TOF MS database for the identification of Gram-positive anaerobic cocci

    DEFF Research Database (Denmark)

    Veloo, A C M; de Vries, E D; Jean-Pierre, H

    2016-01-01

    Gram-positive anaerobic cocci (GPAC) account for 24%-31% of the anaerobic bacteria isolated from human clinical specimens. At present, GPAC are under-represented in the Biotyper MALDI-TOF MS database. Profiles of new species have yet to be added. We present the optimization of the matrix-assisted......Gram-positive anaerobic cocci (GPAC) account for 24%-31% of the anaerobic bacteria isolated from human clinical specimens. At present, GPAC are under-represented in the Biotyper MALDI-TOF MS database. Profiles of new species have yet to be added. We present the optimization of the matrix......-assisted laser desorption-ionization time-of-flight mass spectrometry (MALDI-TOF MS) database for the identification of GPAC. Main spectral profiles (MSPs) were created for 108 clinical GPAC isolates. Identity was confirmed using 16S rRNA gene sequencing. Species identification was considered to be reliable...... if the sequence similarity with its closest relative was ≥98.7%. The optimized database was validated using 140 clinical isolates. The 16S rRNA sequencing identity was compared with the MALDI-TOF MS result. MSPs were added from 17 species that were not yet represented in the MALDI-TOF MS database or were under...

  3. Neutron Energy Spectra and Yields from the 7Li(p,n) Reaction for Nuclear Astrophysics

    Science.gov (United States)

    Tessler, M.; Friedman, M.; Schmidt, S.; Shor, A.; Berkovits, D.; Cohen, D.; Feinberg, G.; Fiebiger, S.; Krása, A.; Paul, M.; Plag, R.; Plompen, A.; Reifarth, R.

    2016-01-01

    Neutrons produced by the 7Li(p, n)7Be reaction close to threshold are widely used to measure the cross section of s-process nucleosynthesis reactions. While experiments have been performed so far with Van de Graaff accelerators, the use of RF accelerators with higher intensities is planned to enable investigations on radioactive isotopes. In parallel, high-power Li targets for the production of high-intensity neutrons at stellar energies are developed at Goethe University (Frankfurt, Germany) and SARAF (Soreq NRC, Israel). However, such setups pose severe challenges for the measurement of the proton beam intensity or the neutron fluence. In order to develop appropriate methods, we studied in detail the neutron energy distribution and intensity produced by the thick-target 7Li(p,n)7Be reaction and compared them to state-of- the-art simulation codes. Measurements were performed with the bunched and chopped proton beam at the Van de Graaff facility of the Institute for Reference Materials and Measurements (IRMM) using the time-of-flight (TOF) technique with thin (1/8") and thick (1") detectors. The importance of detailed simulations of the detector structure and geometry for the conversion of TOF to a neutron energy is stressed. The measured neutron spectra are consistent with those previously reported and agree well with Monte Carlo simulations that include experimentally determined 7Li(p,n) cross sections, two-body kinematics and proton energy loss in the Li-target.

  4. MALDI-TOF mass spectrometry and high-consequence bacteria: safety and stability of biothreat bacterial sample testing in clinical diagnostic laboratories.

    Science.gov (United States)

    Tracz, Dobryan M; Tober, Ashley D; Antonation, Kym S; Corbett, Cindi R

    2018-03-01

    We considered the application of MALDI-TOF mass spectrometry for BSL-3 bacterial diagnostics, with a focus on the biosafety of live-culture direct-colony testing and the stability of stored extracts. Biosafety level 2 (BSL-2) bacterial species were used as surrogates for BSL-3 high-consequence pathogens in all live-culture MALDI-TOF experiments. Viable BSL-2 bacteria were isolated from MALDI-TOF mass spectrometry target plates after 'direct-colony' and 'on-plate' extraction testing, suggesting that the matrix chemicals alone cannot be considered sufficient to inactivate bacterial culture and spores in all samples. Sampling of the instrument interior after direct-colony analysis did not recover viable organisms, suggesting that any potential risks to the laboratory technician are associated with preparation of the MALDI-TOF target plate before or after testing. Secondly, a long-term stability study (3 years) of stored MALDI-TOF extracts showed that match scores can decrease below the threshold for reliable species identification (<1.7), which has implications for proficiency test panel item storage and distribution.

  5. DBDA as a Novel Matrix for the Analyses of Small Molecules and Quantification of Fatty Acids by Negative Ion MALDI-TOF MS.

    Science.gov (United States)

    Ling, Ling; Li, Ying; Wang, Sheng; Guo, Liming; Xiao, Chunsheng; Chen, Xuesi; Guo, Xinhua

    2018-04-01

    Matrix interference ions in low mass range has always been a concern when using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) to analyze small molecules (matrix, N1,N4-dibenzylidenebenzene-1,4-diamine (DBDA) was synthesized for the analyses of small molecules by negative ion MALDI-TOF MS. Notably, only neat ions ([M-H] - ) of fatty acids without matrix interference appeared in the mass spectra and the limit of detection (LOD) reached 0.3 fmol. DBDA also has great performance towards other small molecules such as amino acids, peptides, and nucleotide. Furthermore, with this novel matrix, the free fatty acids in serum were quantitatively analyzed based on the correlation curves with correlation coefficient of 0.99. In addition, UV-Vis experiments and molecular orbital calculations were performed to explore mechanism about DBDA used as matrix in the negative ion mode. The present work shows that the DBDA matrix is a highly sensitive matrix with few interference ions for analysis of small molecules. Meanwhile, DBDA is able to precisely quantify the fatty acids in real biological samples. Graphical Abstract ᅟ.

  6. Preliminary measurements on the new TOF system installed at the AMS beamline of INFN-LABEC

    Energy Technology Data Exchange (ETDEWEB)

    Palla, L., E-mail: palla@fi.infn.it [Dipartimento di Fisica, Università di Pisa, e INFN Sezione di Pisa (Italy); Castelli, L. [INFN Sezione di Firenze (Italy); Czelusniak, C. [INFN Sezione di Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze (Italy); Fedi, M.E. [INFN Sezione di Firenze (Italy); Giuntini, L. [INFN Sezione di Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze (Italy); Liccioli, L. [INFN Sezione di Firenze (Italy); Dipartimento di Chimica Ugo Schiff, Università di Firenze (Italy); Mandò, P.A. [INFN Sezione di Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze (Italy); Martini, M. [Dipartimento di Scienza dei Materiali, Università di Milano Bicocca, e INFN Sezione di Milano Bicocca, Milano (Italy); Mazzinghi, A. [INFN Sezione di Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze (Italy); Ruberto, C. [INFN Sezione di Firenze (Italy); Dipartimento di Chimica Ugo Schiff, Università di Firenze (Italy); Schiavulli, L. [Dipartimento di Fisica, Università di Bari, e INFN Sezione di Bari (Italy); Sibilia, E. [Dipartimento di Scienza dei Materiali, Università di Milano Bicocca, e INFN Sezione di Milano Bicocca, Milano (Italy); Taccetti, F. [INFN Sezione di Firenze (Italy)

    2015-10-15

    A high resolution time of flight (TOF) system has been developed at LABEC, the 3 MV Tandem accelerator laboratory in Florence, in order to improve the sensitivity of AMS measurements on carbon samples with ultra-low concentration and also to measure other isotopes, such as {sup 129}I. The system can be employed to detect and identify residual interfering particles originated from the break-up of molecular isobars. The set-up has been specifically designed for low energy heavy ions: it consists of two identical time pick-off stations, each made up of a thin conductive foil and a Micro-Channel Plate (MCP) multiplier. The beamline is also equipped with a silicon detector, installed downstream the stop TOF station. In this paper the design of the new system and the implemented readout electronics are presented. The tests performed on the single time pick-off station are reported: they show that the maximum contribution to the timing resolution given by both the intrinsic MCP resolution and the electronics is ⩽500 ps (FWHM). For these tests, single particle pulsed beams of 2–5 MeV protons and 10 MeV {sup 12}C{sup 3+} ions, to simulate typical AMS conditions, were used. The preliminary TOF and TOF-E (TOF-energy) measurements performed with carbon beams after the installation of the new system on the AMS beam line are also discussed. These measurements were performed using the foil–MCP as the start stage and a silicon detector as the stop stage. The spectra acquired with carbon ions suggest the presence of a small residual background from neighboring masses reaching the end of the beamline with the same energy as the rare isotope.

  7. Preliminary measurements on the new TOF system installed at the AMS beamline of INFN-LABEC

    International Nuclear Information System (INIS)

    Palla, L.; Castelli, L.; Czelusniak, C.; Fedi, M.E.; Giuntini, L.; Liccioli, L.; Mandò, P.A.; Martini, M.; Mazzinghi, A.; Ruberto, C.; Schiavulli, L.; Sibilia, E.; Taccetti, F.

    2015-01-01

    A high resolution time of flight (TOF) system has been developed at LABEC, the 3 MV Tandem accelerator laboratory in Florence, in order to improve the sensitivity of AMS measurements on carbon samples with ultra-low concentration and also to measure other isotopes, such as "1"2"9I. The system can be employed to detect and identify residual interfering particles originated from the break-up of molecular isobars. The set-up has been specifically designed for low energy heavy ions: it consists of two identical time pick-off stations, each made up of a thin conductive foil and a Micro-Channel Plate (MCP) multiplier. The beamline is also equipped with a silicon detector, installed downstream the stop TOF station. In this paper the design of the new system and the implemented readout electronics are presented. The tests performed on the single time pick-off station are reported: they show that the maximum contribution to the timing resolution given by both the intrinsic MCP resolution and the electronics is ⩽500 ps (FWHM). For these tests, single particle pulsed beams of 2–5 MeV protons and 10 MeV "1"2C"3"+ ions, to simulate typical AMS conditions, were used. The preliminary TOF and TOF-E (TOF-energy) measurements performed with carbon beams after the installation of the new system on the AMS beam line are also discussed. These measurements were performed using the foil–MCP as the start stage and a silicon detector as the stop stage. The spectra acquired with carbon ions suggest the presence of a small residual background from neighboring masses reaching the end of the beamline with the same energy as the rare isotope.

  8. Use of Maldi-Tof Mass spectrometry in direct microorganism identification in clinical laboratories

    Directory of Open Access Journals (Sweden)

    Tamara Brunelli

    2010-09-01

    Full Text Available Mass Spectrometry is an old technique that has recently been introduced in the clinical microbiology laboratory as Matrix Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry (MALDI-TOF MS. MALDI is a soft ionization technique used in mass spectrometry that allows the analysis of biomolecules and large organic molecules which tend to be fragile and fragment when ionized.To obtain ions biological specimens are mixed with a matrix which specifically absorbs the ionization source (a laser beam. The high energy impact is followed by the formation of ions which are extract through an elastic field, focussed and detected as mass/charge (m/z spectrum.The differences between ions are seen with TOF, a revelation system that relates the time of flight of a ion to the charge/mass value: ion with a higher m/z have are slower (a bigger time of flight than ions with lower m/z. MALDI-TOF MS, in clinical microbiology laboratory, is used to identify bacteria and fungi directly from samples. The identification of microorganisms can be performed directly from body fluids (e.g. urine, blood culture, after centrifugation and recovery of microorganisms or from colonies (after cultivation. The rapidity of identification is of great importance in blood cultures. Positive cultures with one microorganism are processed in a different way than those with more than one microorganism. In positive monomicrobial cultures, after separation of microbs from blood cells,we can perform an immediate identification with MALDI-TOF MS that we can communicate to the clinician, and that gives indication to perform the correct antibiogram. Major problems are present when more than one microorganism are in the culture: in this case we have to use the method of subcultivation and then the identification with mass-spectrometry can be performed. MALDI-TOF MS is a rapid, reliable and low cost technique, that can identify a growing number of microorganisms. This technique can

  9. Seldi-tof MS Profiling of Plasma Proteins in Ovarian Cancer

    Directory of Open Access Journals (Sweden)

    Shao-Pai Wu

    2006-03-01

    Conclusion: This study clearly demonstrates that the combined technology of SELDI-TOF MS and artificial intelligence is effective in distinguishing protein expression between normal and ovarian cancer plasma. The identified protein peaks may be candidate proteins for early detection of ovarian cancer or evaluation of therapeutic response.

  10. Characterization of polymer solar cells by TOF-SIMS depth profiling

    NARCIS (Netherlands)

    Bulle-Lieuwma, C.W.T.; Gennip, van W.J.H.; Duren, van J.K.J.; Jonkheijm, P.; Janssen, R.A.J.; Niemantsverdriet, J.W.

    2003-01-01

    Solar cells consisting of polymer layers sandwiched between a transparent electrode on glass and a metal top electrode are studied using dynamic time-of-flight secondary ion mass spectrometry (TOF-SIMS) in dual-beam mode. Because depth profiling of polymers and polymer-metal stacks is a relatively

  11. High resolution time-of-flight (TOF) detector for particle identification

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, Merlin; Lehmann, Albert; Pfaffinger, Markus; Uhlig, Fred [Physikalisches Institut, Universitaet Erlangen-Nuernberg (Germany); Collaboration: PANDA-Collaboration

    2016-07-01

    Several prototype tests were performed with the PANDA DIRC detectors at the CERN T9 beam line. A mixed hadron beam with pions, kaons and protons was used at momenta from 2 to 10 GeV/c. For these tests a good particle identification was mandatory. We report about a high resolution TOF detector built especially for this purpose. It consists of two stations each consisting of a Cherenkov radiator read out by a Microchannel-Plate Photomultiplier (MCP-PMT) and a Scintillating Tile (SciTil) counter read out by silicon photomultipliers (SiPMs). With a flight path of 29 m a pion/kaon separation up to 5 GeV/c and a pion/proton separation up to 10 GeV/c was obtained. From the TOF resolutions of different counter combinations the time resolution (sigma) of the individual MCP-PMTs and SciTils was determined. The best counter reached a time resolution of 50 ps.

  12. Mesure de la violation de CP dans les désintégrations B$_{\\textrm{s}}^0 \\to$ $J/\\psi \\phi$, auprès du détecteur LHCb

    CERN Document Server

    Maurice, Emilie; Le Gac, Renaud

    La mesure de la phase $\\phi_{\\textrm{s}}$ violant la symétrie CP dans les désintégrations B$^0_{\\textrm s} \\to$ J$/\\psi \\phi$ est une des analyses phares de l'expérience LHCb. Le Modèle Standard prédit cette observable avec une faible incertitude théorique. La présence de Nouvelle Physique notamment dans les diagrammes en boucle de l'oscillation B$^0_{\\textrm s}$-$\\overline{\\textrm{B}}^0_{\\textrm s}$ peut significativement modifier la mesure de cette phase. Durant cette thèse, nous avons participé à différents aspects de l'analyse des désintégrations B$^0_{\\textrm s} \\to$ J$/\\psi \\phi$. Nous avons proposé une sélection multi-variables, basée sur un algorithme d'arbres de décision boostés. Cette nouvelle sélection augmente le nombre de signal B$^0_{\\textrm s} \\to$ J$/\\psi \\phi$ de 19$\\%$ mais nécessite une correction temporelle. Une étude portant sur l'origine des distorsions angulaires caractéristiques des désintégrations B$^0_{\\textrm s} \\to $J$/\\psi \\phi$ a aussi été menée. Il...

  13. Simplifying the Preparation of Pollen Grains for MALDI-TOF MS Classification

    Directory of Open Access Journals (Sweden)

    Franziska Lauer

    2017-03-01

    Full Text Available Matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS is a well-implemented analytical technique for the investigation of complex biological samples. In MS, the sample preparation strategy is decisive for the success of the measurements. Here, sample preparation processes and target materials for the investigation of different pollen grains are compared. A reduced and optimized sample preparation process prior to MALDI-TOF measurement is presented using conductive carbon tape as target. The application of conductive tape yields in enhanced absolute signal intensities and mass spectral pattern information, which leads to a clear separation in subsequent pattern analysis. The results will be used to improve the taxonomic differentiation and identification, and might be useful for the development of a simple routine method to identify pollen based on mass spectrometry.

  14. Comparison among four proposed direct blood culture microbial identification methods using MALDI-TOF MS

    Directory of Open Access Journals (Sweden)

    Ali M. Bazzi

    2017-05-01

    Full Text Available Summary: Matrix-assisted laser desorption-ionization time-of-flight (MALDI-TOF mass spectrometry facilitates rapid and accurate identification of pathogens, which is critical for sepsis patients.In this study, we assessed the accuracy in identification of both Gram-negative and Gram-positive bacteria, except for Streptococcus viridans, using four rapid blood culture methods with Vitek MALDI-TOF-MS. We compared our proposed lysis centrifugation followed by washing and 30% acetic acid treatment method (method 2 with two other lysis centrifugation methods (washing and 30% formic acid treatment (method 1; 100% ethanol treatment (method 3, and picking colonies from 90 to 180 min subculture plates (method 4. Methods 1 and 2 identified all organisms down to species level with 100% accuracy, except for Streptococcus viridans, Streptococcus pyogenes, Enterobacter cloacae and Proteus vulgaris. The latter two were identified to genus level with 100% accuracy. Each method exhibited excellent accuracy and precision in terms of identification to genus level with certain limitations. Keywords: MALDI-TOF, Gram-negative, Gram-positive, Sepsis, Blood culture

  15. Exploring MALDI-TOF MS approach for a rapid identification of Mycobacterium avium ssp. paratuberculosis field isolates.

    Science.gov (United States)

    Ricchi, M; Mazzarelli, A; Piscini, A; Di Caro, A; Cannas, A; Leo, S; Russo, S; Arrigoni, N

    2017-03-01

    The aim of the study was to explore the suitability of matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) for a rapid and correct identification of Mycobacterium avium ssp. paratuberculosis (MAP) field isolates. MALDI-TOF MS approach is becoming one of the most popular tests for the identification of intact bacterial cells which has been shown to be fast and reliable. For this purpose, 36 MAP field isolates were analysed through MALDI-TOF MS and the spectra compared with two different databases: one provided by the vendor of the system employed (Biotyper ver. 3·0; Bruker Daltonics) and a homemade database containing spectra from both tuberculous and nontuberculous Mycobacteria. Moreover, principal component analysis procedure was employed to confirm the ability of MALDI-TOF MS to discriminate between very closely related subspecies. Our results suggest MAP can be differentiated from other Mycobacterium species, both when the species are very close (M. intracellulare) and when belonging to different subspecies (M. avium ssp. avium and M. avium ssp. silvaticum). The procedure applied is fast, easy to perform, and achieves an earlier accurate species identification of MAP and nontuberculous Mycobacteria in comparison to other procedures. The gold standard test for the diagnosis of paratuberculosis is still isolation of MAP by cultural methods, but additional assays, such as qPCR and subculturing for determination of mycobactin dependency are required to confirm its identification. We have provided here evidence pertaining to the usefulness of MALDI-TOF MS approach for a rapid identification of this mycobacterium among other members of M. avium complex. © 2016 The Society for Applied Microbiology.

  16. Measurement of the 243Am capture cross section at the n{sub T}OF facility; Medida de la sección eficaz de captura del 243Am en la instalación n{sub T}OF

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza Cembranos, E.

    2014-07-01

    Nuclear data for minor actinides are necessary for improving the design and performance of advanced reactors and transmutation devices for the incineration of radioactive nuclear waste [Sal08, Gon09, Ali04, Ali06]. In particular, the 243Am isotope is relevant since it is the minor actinide which contributes more to the radiotoxicity of the nuclear waste between s3 03 and s3 04 years. In addition, the neutron capture in 243Am is the main gate to the creation of 244Cm and higher mass isotopes. The purpose of the this work is to provide experimental data on the 243Am(n, ) for improving the current evaluations. At present, there is no published neutron capture measurement of 243Am below 250 eV, and all the existing evaluations of the elastic and capture cross sections are based essentially on a single transmission measurement [Sim74]. Above 250 eV there are only a few capture measurements available [Wes85, Wis83], which show discrepancies that make them incompatible. Due to the lack of experimental data on 243Am the standard ENDF-6 format libraries present sizeable di rences between each other...(Author)

  17. Impact of Nitrification on the Formation of N-Nitrosamines and Halogenated Disinfection Byproducts within Distribution System Storage Facilities.

    Science.gov (United States)

    Zeng, Teng; Mitch, William A

    2016-03-15

    Distribution system storage facilities are a critical, yet often overlooked, component of the urban water infrastructure. This study showed elevated concentrations of N-nitrosodimethylamine (NDMA), total N-nitrosamines (TONO), regulated trihalomethanes (THMs) and haloacetic acids (HAAs), 1,1-dichloropropanone (1,1-DCP), trichloroacetaldehyde (TCAL), haloacetonitriles (HANs), and haloacetamides (HAMs) in waters with ongoing nitrification as compared to non-nitrifying waters in storage facilities within five different chloraminated drinking water distribution systems. The concentrations of NDMA, TONO, HANs, and HAMs in the nitrifying waters further increased upon application of simulated distribution system chloramination. The addition of a nitrifying biofilm sample collected from a nitrifying facility to its non-nitrifying influent water led to increases in N-nitrosamine and halogenated DBP formation, suggesting the release of precursors from nitrifying biofilms. Periodic treatment of two nitrifying facilities with breakpoint chlorination (BPC) temporarily suppressed nitrification and reduced precursor levels for N-nitrosamines, HANs, and HAMs, as reflected by lower concentrations of these DBPs measured after re-establishment of a chloramine residual within the facilities than prior to the BPC treatment. However, BPC promoted the formation of halogenated DBPs while a free chlorine residual was maintained. Strategies that minimize application of free chlorine while preventing nitrification are needed to control DBP precursor release in storage facilities.

  18. Fission ionisation chamber for the measurement of low fluxes of slow neutrons; Chambre d'ionisation a fission pour la mesure des faibles flux de neutrons lents

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J; Duchene, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The ionisation chamber described is designed for the measurement of slow neutron fluxes of average or low intensity, in the presence, eventually, of very high gamma fluxes. The capture of a slow neutron by a fissile material, in this case {sup 235}U, gives rise to fission fragments, high-energy particles which ionise the gas contained in the chamber. The neutrons are detected by virtue of the potential pulses, on the collecting electrode of the chamber, deriving from the collection of the ions produced by the fission fragments. The pulses are counted by means of a measuring system consisting of a preamplifier, a 2 Mc amplifier, a discriminator and an electronic scale with numerator or integrator. The general characteristics are as follows: sensitivity to neutrons: 0.07 kicks/n/cm{sup 2}.s, sensitivity to {gamma} rays: zero up to 3.10{sup 4} R/H, a background noise at the normal discrimination voltage: 0.01 kicks/s, working H.T.: -500 V, capacity: 40 {mu}{mu}F, average height of pulse: 8 mV, limits of use: from several neutrons to 10{sup 6} n/cm{sup 2}.s. This chamber may be used in all cases where low fluxes of slow neutrons must be measured, especially in the presence of high gamma fluxes, for example in the checking of Pu concentrations in an extraction plant or for the starting up of reactors. (author) [French] La chambre d'ionisation decrite est destinee a la mesure des flux de neutrons lents d'intensite moyenne ou faible, en presence eventuelle de flux gamma tres importants. La capture d'un neutron lent par un materiau fissile, en l'occurrence {sup 235}U, donne naissance a des fragments de fission, particules de grande energie qui ionisent le gaz contenu dans la chambre. Les neutrons sont detectes grace aux impulsions de potentiel, sur l'electrode collectrice de la chambre, provenant de la collection des ions produits par les fragments de fission. Une chaine de mesure comprenant un preamplificateur, un amplificateur 2 Mc, un discriminateur, une echelle

  19. Thermal neutron flux measurements using neutron-electron converters; Mesure de flux de neutrons thermiques avec des convertisseurs neutrons electrons

    Energy Technology Data Exchange (ETDEWEB)

    Le Meur, R; Lecomte, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    The operation of neutron-electron converters designed for measuring thermal neutron fluxes is examined. The principle is to produce short lived isotopes emitting beta particles, by activation, and to measure their activity not by extracting them from the reactor, but directly in the reactor using the emitted electrons to deflect the needle of a galvanometer placed outside the flux. After a theoretical study, the results of the measurements are presented; particular attention is paid to a new type of converter characterized by a layer structure. The converters are very useful for obtaining flux distributions with more than 10{sup 7} neutrons cm{sup -2}*sec{sup -1}. They work satisfactorily in pressurized carbon dioxide at 400 Celsius degrees. Some points still have to be cleared up however concerning interfering currents in the detectors and the behaviour of the dielectrics under irradiation. (authors) [French] On examine le fonctionnement de convertisseurs neutrons electrons destines a des mesures de flux de neutrons thermiques. Le principe est de former par activation des isotopes a periodes courtes et a emission beta et de mesurer leur activite non pas en les sortant du reacteur, mais directement en pile, utilisant les electrons emis pour faire devier l'aiguille d'un galvanometre place hors flux. Apres une etude theorique, on indique des resultats de mesures obtenus, en insistant particulierement sur un nouveau type de convertisseur, caracterise par sa structure stratifiee. Les convertisseurs sont tres interessants pour tracer, des cartes de flux a partir de 10{sup 7} neutrons cm{sup -2}*s{sup -1}. Ils sont utilisables pour des flux de 10{sup 14} neutrons cm{sup -2}*s{sup -1}. Ils fonctionnent correctement dans du gaz carbonique sous pression a 400 C. Des points restent cependant a eclaircir concernant les courants parasites dans les detecteurs et le comportement des dielectriques pendant leur irradiation. (auteur)

  20. Time expanding multihit TDC for the BELLE TOF detector at the KEK B-factory

    International Nuclear Information System (INIS)

    Varner, G.; Kichimi, H.; Yamaguchi, H.

    1997-01-01

    Utilizing a time expansion technique, a multihit TDC has been developed for readout of the BELLE TOF detector at the KEK B-Factory. Time digitization consists of three steps: tagging an input signal with respect to a beam collision synchronized reference clock, expansion of this time interval, and readout by a conventional multihit TDC. Using a time expansion factor of 20 and a multihit TDC with a 500 ps LSB, this system provides a precision TOF measurement of 25 ps LSB, ∼20 ps resolution, and with a dead time of less than 1 μs

  1. CERN rupture des négociations

    CERN Multimedia

    1990-01-01

    "Le Comité du Conseil du Centre européen de recherches nucléaires (CERN) a déchiré jeudi le paquet de mesures négociées pendant l'été par le personnel avec la direction. Les négociations directes sur les conditions d'emploi "n'étaient qu'un faux-semblant", a déclaré vendredi l'Association du personnel du CERN, qui demande la démission immédiate du président du Conseil et du directeur général et prévoit une grève du zèle" (0.5 page)

  2. Advantages of TOF-SIMS analysis of hydroxyapatite and fluorapatite in comparison with XRD, HR-TEM and FT-IR.

    Science.gov (United States)

    Okazaki, Masayuki; Hirata, Isao; Matsumoto, Takuya; Takahashi, Junzo

    2005-12-01

    The chemical analysis of hydroxyapatite and fluorapatite was carried out using time-of-flight secondary ion mass spectrometry (TOF-SIMS). Hydroxyapatite and fluorapatite were synthesized at 80 +/- 1 degrees C and pH 7.4 +/- 0.2. Fluorapatite was better crystallized, with its (300) reflection shifted to a slightly higher angle. High-resolution transmission electron microscopy clearly revealed a typical, regular hexagonal cross section perpendicular to the c-axis for fluorapatite and a flattened hexagonal cross section for hydroxyapatite. FT-IR spectra of fluorapatite confirmed the absence of OH absorption peak--which was seen in hydroxyapatite at about 3570 cm(-1). TOF-SIMS mass spectra showed a peak at 40 amu due to calcium. In addition, a peak at 19 amu due to fluorine could be clearly seen, although the intensities of PO, PO2, and PO3 were very low. It was confirmed that TOF-SIMS clearly showed the differences between positive and negative mass spectra of hydroxyapatite and fluorapatite, especially for F-. We concluded that TOF-SIMS exhibited distinct advantages compared with other methods of analysis.

  3. Analyse du capital humain : diagnostic des dépenses d'éducation au Sénégal

    OpenAIRE

    Youssouph Ba

    2011-01-01

    Le but de notre travail consistait dans un premier temps à revisiter les soubassements théoriques du capital humain et savoir si l'augmentation du capital humain a un effet ponctuel sur la croissance économique (aussi bien dans la sphère des pays industrialisés que dans celle des pays en développement). Dans un second temps, il consistait à mesurer la politique du Sénégal en terme de capital humain : mesurer les efforts de financement de l'éducation d'une part et d'autre part, voir si ces eff...

  4. The subunits of the S-phase checkpoint complex Mrc1/Tof1/Csm3: dynamics and interdependence.

    Science.gov (United States)

    Uzunova, Sonya Dimitrova; Zarkov, Alexander Stefanov; Ivanova, Anna Marianova; Stoynov, Stoyno Stefanov; Nedelcheva-Veleva, Marina Nedelcheva

    2014-01-01

    The S-phase checkpoint aims to prevent cells from generation of extensive single-stranded DNA that predisposes to genome instability. The S. cerevisiae complex Tof1/Csm3/Mrc1 acts to restrain the replicative MCM helicase when DNA synthesis is prohibited. Keeping the replication machinery intact allows restart of the replication fork when the block is relieved. Although the subunits of the Tof1/Csm3/Mrc1 complex are well studied, the impact of every single subunit on the triple complex formation and function needs to be established. This work studies the cellular localization and the chromatin binding of GFP-tagged subunits when the complex is intact and when a subunit is missing. We demonstrate that the complex is formed in cell nucleus, not the cytoplasm, as Tof1, Csm3 and Mrc1 enter the nucleus independently from one another. Via in situ chromatin binding assay we show that a Tof1-Csm3 dimer formation and chromatin binding is required to ensure the attachment of Mrc1 to chromatin. Our study indicates that the translocation into the nucleus is not the process to regulate the timing of chromatin association of Mrc1. We also studied the nuclear behavior of Mrc1 subunit in the process of adaptation to the presence hydroxyurea. Our results indicate that after prolonged HU incubation, cells bypass the S-phase checkpoint and proceed throughout the cell cycle. This process is accompanied by Mrc1 chromatin detachment and Rad53 dephosphorylation. In S. cerevisiae the subunits of the S-phase checkpoint complex Mrc1/Tof1/Csm3 independently enter the cell nucleus, where a Tof1-Csm3 dimer is formed to ensure the chromatin binding of Mrc1 and favor DNA replication and S-phase checkpoint fork arrest. In the process of adaptation to the presence of hydroxyurea Mrc1 is detached from chromatin and Rad53 checkpoint activity is diminished in order to allow S-phase checkpoint escape and completion of the cell cycle.

  5. Evaluation technique des analyseurs de mesure de la qualité de l'air

    OpenAIRE

    Tatry , Véronique

    1996-01-01

    Les objectifs des évaluations techniques des analyseurs de mesure de la qualité de l'air sont : de vérifier les performances métrologiques de ces analyseurs, de connaître la capacité des appareils à travailler sur le terrain, d'évaluer la capacité du fournisseur à résoudre les problèmes techniques que pose l'exploitation de son appareil. Cette activité existe à l'INERIS depuis plus de 20 ans (ex CERCHAR et ex IRCHA). Elle s'appuie sur une procédure décrite dans la norme française NF X 20-300 ...

  6. Radioelements: their detection and measurement; Les radioelements: detection et mesure

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, B [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    A brief review of the properties of nuclear radiations is followed by a description of the basic techniques used for their detection: autoradiography, methods using the ionisation of gases (ionisation chambers, proportional counters, Geiger-Muller counters), scintillation techniques. The principles of the different methods of measurement are explained, whether they concern the activity or the energy absorbed (dosimetry). This is followed by a description of the basic techniques (4 {pi} counter, defined solid angle, {beta}-{gamma} coincidences). (author) [French] Apres un bref rappel des proprietes des rayonnements nucleaires, on decrit les techniques fondamentales employees pour leur detection: autoradiographie, procedes utilisant l'ionisation des gaz (chambres d'ionisation, compteurs proportionnels, compteurs de Geiger-Muller), technique des scintillations. On expose le principe des differentes methodes de mesure concernant soit l'activite, soit l'energie absorbee (dosimetrie). Les techniques fondamentales (compteur 4 {pi}, angle solide defini, coincidences {beta}-{gamma}) sont ensuite decrites. (auteur)

  7. A study on development of fast silicon photomultipliers for TOF-PET Application

    International Nuclear Information System (INIS)

    Lee, Chae Hun

    2011-02-01

    micro-pixels with 66 % fill factor. At this condition, the dynamic range was appropriate for measurement of 511 keV gamma photons with LYSO coupling. Additionally integrated quenching capacitors were fabricated with the Metal-Insulator-Metal (MIM) structure which is commonly used in standard CMOS processes. Quenching capacitor C q with 30 fF successfully modified the single photon pulse shape of SiPM. The initial current in the single photon pulse shape was increased, so, the pulse shape became shaper than conventional SiPMs. This sharper pulse shape shortens the rise time of PET detectors coupled to LYSO. 10 to 90 % rise time of the PET detector based on C q integrated SiPM was 22.5 ns while the normal SiPM has 34.3 ns. The performance of fabricated SiPM was experimentally evaluated with parameters such as reverse bias characteristics, single photoelectron spectrum, gain, dark count rate, energy resolution, and Photon Detection efficiency (PDE). The breakdown voltage was around 16.5 V, so the operating voltage was 17 V to 18V. The gain was obtained with the mean spacing method from single photoelectron spectra, and high gain about 2x10 6 was measured. In Na-22 spectrum measurements, the energy resolution was better than 15 % FWHM at 511 keV which is good enough to use in PET. The experimental results show its feasibility to use in TOF-PET application. The fabricated SiPM has better performances than commercial SiPMs except for dark count rates. Due to N+ formation by the direct arsenic implantation, dark count rate was higher than commercials. As a future work, the SiPM fabrication process scheme is needed to study in order to reduce the dark count rate

  8. Cosensitized Porphyrin System for High-Performance Solar Cells with TOF-SIMS Analysis.

    Science.gov (United States)

    Wu, Wenjun; Xiang, Huaide; Fan, Wei; Wang, Jinglin; Wang, Haifeng; Hua, Xin; Wang, Zhaohui; Long, Yitao; Tian, He; Zhu, Wei-Hong

    2017-05-17

    To date, development of organic sensitizers has been predominately focused on light harvesting, highest occupied molecular orbital and lowest unoccupied molecular orbital energy levels, and the electron transferring process. In contrast, their adsorption mode as well as the dynamic loading behavior onto nanoporous TiO 2 is rarely considered. Herein, we have employed the time-of-flight secondary ion mass spectrometry (TOF-SIMS) to gain insight into the competitive dye adsorption mode and kinetics in the cosensitized porphyrin system. Using novel porphyrin dye FW-1 and D-A-π-A featured dye WS-5, the different bond-breaking mode in TOF-SIMS and dynamic dye-loading amount during the coadsorption process are well-compared with two different anchoring groups, such as benzoic acid and cyanoacrylic acid. With the bombardment mode in TOF-SIMS spectra, we have speculated that the cyano group grafts onto nanoporous TiO 2 as tridentate binding for the common anchoring unit of cyanoacrylic acid and confirmed it through extensive first-principles density functional theory calculation by anchoring either the carboxyl or cyano group, which shows that the cyano group can efficiently participate in the adsorption of the WS-5 molecule onto the TiO 2 nanocrystal. The grafting reinforcement interaction between the cyano group and TiO 2 in WS-5 can well-explain the rapid adsorption characteristics. A strong coordinate bond between the lone pair of electrons on the nitrogen or oxygen atom and the Lewis acid sites of TiO 2 can increase electron injection efficiencies with respect to those from the bond between the benzoic acid group and the Brønsted acid sites of the TiO 2 surface. Upon optimization of the coadsorption process with dye WS-5, the photoelectric conversion efficiency based on porphyrin dye FW-1 is increased from 6.14 to 9.72%. The study on the adsorption dynamics of organic sensitizers with TOF-SIMS analysis might provide a new venue for improvement of cosensitized solar

  9. The optimization and validation of the Biotyper MALDI-TOF MS database for the identification of Gram-positive anaerobic cocci

    NARCIS (Netherlands)

    Veloo, A. C. M.; de Vries, E D; Jean-Pierre, H.; Justesen, U. S.; Morris, T.; Urban, E.; Wybo, I.; van Winkelhoff, A. J.

    OBJECTIVES: Gram-positive anaerobic cocci (GPAC) account for 24-31% of the anaerobic bacteria isolated from human clinical specimens. At present GPAC are underrepresented in the Biotyper MALDI-TOF MS database. Profiles of new species have yet to be added. We present the optimization of the MALDI-TOF

  10. Direct identification from Bact/Alert™ blood culture bottles by MALDI-TOF

    Directory of Open Access Journals (Sweden)

    Vesselina Kroumova

    2011-12-01

    Full Text Available Bacterial identification from blood culture using traditional methods needs about 48 hours, since positivization, to be performed. Rapid bacterial identification can result in clinical and economic benefits. To provide rapid pathogen identification for targeted antibiotic treatment, in this study we tested an our previously described homemade method for bacterial identification using MALDI-TOF directly from positive BACTEC blood culture, on positive BacT/ALERT blood culture. A total of 108 bacteria were identified by MALDI-TOF with a positive identification obtained for 98% of Gram negative and 84,3% of Gram positive bacteria.The average of identification score obtained using the protocol described in this study was 2,047 for Gram positive and 2,204 for Gram negative microorganisms. Data here described show that this method is also useful when BacT/ALERT bottles are used and even if these bottles have activated charcoal as inhibitor of antibiotics.

  11. Chemical Visualization of Sweat Pores in Fingerprints Using GO-Enhanced TOF-SIMS.

    Science.gov (United States)

    Cai, Lesi; Xia, Meng-Chan; Wang, Zhaoying; Zhao, Ya-Bin; Li, Zhanping; Zhang, Sichun; Zhang, Xinrong

    2017-08-15

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has been used in imaging of small molecules (SIMS was used to detect and image relatively high mass molecules such as poison, alkaloids (>600 Da) and controlled drugs, and antibiotics (>700 Da) in fingerprints. Detail features of fingerprints such as the number and distribution of sweat pores in a ridge and even the delicate morphology of one pore were clearly revealed in SIMS images of relatively high mass molecules. The detail features combining with identified chemical composition were sufficient to establish a human identity and link the suspect to a crime scene. The wide detectable mass range and high spatial resolution make GO-enhanced TOF-SIMS a promising tool in accurate and fast analysis of fingerprints, especially in fragmental fingerprint analysis.

  12. Design Optimization of a TOF, Breast PET Scanner

    OpenAIRE

    Lee, Eunsin; Werner, Matthew E.; Karp, Joel S.; Surti, Suleman

    2013-01-01

    A dedicated breast positron emission tomography (PET) scanner with limited angle geometry can provide flexibility in detector placement around the patient as well as the ability to combine it with other imaging modalities. A primary challenge of a stationary limited angle scanner is the reduced image quality due to artifacts present in the reconstructed image leading to a loss in quantitative information. Previously it has been shown that using time-of-flight (TOF) information in image recons...

  13. Comparison of 3D TOF-MRA and 3D CE-MRA at 3 T for imaging of intracranial aneurysms

    International Nuclear Information System (INIS)

    Cirillo, Mario; Scomazzoni, Francesco; Cirillo, Luigi; Cadioli, Marcello; Simionato, Franco; Iadanza, Antonella; Kirchin, Miles; Righi, Claudio; Anzalone, Nicoletta

    2013-01-01

    Purpose: To compare 3 T elliptical-centric CE MRA with 3 T TOF MRA for the detection and characterization of unruptured intracranial aneurysms (UIAs), by using digital subtracted angiography (DSA) as reference. Materials and methods: Twenty-nine patients (12 male, 17 female; mean age: 62 years) with 41 aneurysms (34 saccular, 7 fusiform; mean diameter: 8.85 mm [range 2.0–26.4 mm]) were evaluated with MRA at 3 T each underwent 3D TOF-MRA examination without contrast and then a 3D contrast-enhanced (CE-MRA) examination with 0.1 mmol/kg bodyweight gadobenate dimeglumine and k-space elliptic mapping (Contrast ENhanced Timing Robust Angiography [CENTRA]). Both TOF and CE-MRA images were used to evaluate morphologic features that impact the risk of rupture and the selection of a treatment. Almost half (20/41) of UIAs were located in the internal carotid artery, 7 in the anterior communicating artery, 9 in the middle cerebral artery and 4 in the vertebro-basilar arterial system. All patients also underwent DSA before or after the MR examination. Results: The CE-MRA results were in all cases consistent with the DSA dataset. No differences were noted between 3D TOF-MRA and CE-MRA concerning the detection and location of the 41 aneurysms or visualization of the parental artery. Differences were apparent concerning the visualization of morphologic features, especially for large aneurysms (>13 mm). An irregular sac shape was demonstrated for 21 aneurysms on CE-MRA but only 13/21 aneurysms on 3D TOF-MRA. Likewise, CE-MRA permitted visualization of an aneurismal neck and calculation of the sac/neck ratio for all 34 aneurysms with a neck demonstrated at DSA. Conversely, a neck was visible for only 24/34 aneurysms at 3D TOF-MRA. 3D CE-MRA detected 15 aneurysms with branches originating from the sac and/or neck, whereas branches were recognized in only 12/15 aneurysms at 3D TOF-MRA. Conclusion: For evaluation of intracranial aneurysms at 3 T, 3D CE-MRA is superior to 3D TOF

  14. The estimation of N2O emissions from municipal solid waste incineration facilities: The Korea case

    International Nuclear Information System (INIS)

    Park, Sangwon; Choi, Jun-Ho; Park, Jinwon

    2011-01-01

    The greenhouse gases (GHGs) generated in municipal solid waste (MSW) incineration are carbon dioxide (CO 2 ), methane (CH 4 ), and nitrous oxide (N 2 O). In South Korea case, the total of GHGs from the waste incineration facilities has been increasing at an annual rate 10%. In these view, waste incineration facilities should consider to reduce GHG emissions. This study is designed to estimate the N 2 O emission factors from MSW incineration plants, and calculate the N 2 O emissions based on these factors. The three MSW incinerators examined in this study were either stoker or both stoker and rotary kiln facilities. The N 2 O concentrations from the MSW incinerators were measured using gas chromatography-electron capture detection (GC-ECD) equipment. The average of the N 2 O emission factors for the M01 plant, M02 plant, and M03 plant are 71, 75, and 153 g-N 2 O/ton-waste, respectively. These results showed a significant difference from the default values of the intergovernmental panel on climate change (IPCC), while approaching those values derived in Japan and Germany. Furthermore, comparing the results of this study to the Korea Energy Economics Institute (KEEI) (2007) data on waste incineration, N 2 O emissions from MSW incineration comprised 19% of the total N 2 O emissions.

  15. The estimation of N2O emissions from municipal solid waste incineration facilities: The Korea case.

    Science.gov (United States)

    Park, Sangwon; Choi, Jun-Ho; Park, Jinwon

    2011-08-01

    The greenhouse gases (GHGs) generated in municipal solid waste (MSW) incineration are carbon dioxide (CO(2)), methane (CH(4)), and nitrous oxide (N(2)O). In South Korea case, the total of GHGs from the waste incineration facilities has been increasing at an annual rate 10%. In these view, waste incineration facilities should consider to reduce GHG emissions. This study is designed to estimate the N(2)O emission factors from MSW incineration plants, and calculate the N(2)O emissions based on these factors. The three MSW incinerators examined in this study were either stoker or both stoker and rotary kiln facilities. The N(2)O concentrations from the MSW incinerators were measured using gas chromatography-electron capture detection (GC-ECD) equipment. The average of the N(2)O emission factors for the M01 plant, M02 plant, and M03 plant are 71, 75, and 153g-N(2)O/ton-waste, respectively. These results showed a significant difference from the default values of the intergovernmental panel on climate change (IPCC), while approaching those values derived in Japan and Germany. Furthermore, comparing the results of this study to the Korea Energy Economics Institute (KEEI) (2007) data on waste incineration, N(2)O emissions from MSW incineration comprised 19% of the total N(2)O emissions. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  16. 2D-DIGE and MALDI TOF/TOF MS analysis reveal that small GTPase signaling pathways may play an important role in cadmium-induced colon cell malignant transformation

    International Nuclear Information System (INIS)

    Lu, Jian; Zhou, Zhongping; Zheng, Jianzhou; Zhang, Zhuyi; Lu, Rongzhu; Liu, Hanqing; Shi, Haifeng; Tu, Zhigang

    2015-01-01

    Cadmium is a toxic heavy metal present in the environment and in industrial materials. Cadmium has demonstrated carcinogenic activity that induces cell transformation, but how this occurs is unclear. We used 2D-DIGE and MALDI TOF/TOF MS combined with bioinformatics and immunoblotting to investigate the molecular mechanism of cadmium transformation. We found that small GTPases were critical for transformation. Additionally, proteins involved in mitochondrial transcription, DNA repair, and translation also had altered expression patterns in cadmium treated cells. Collectively, our results suggest that activation of small GTPases contributes to cadmium-induced transformation of colon cells. - Highlights: • Colon epithelial cell line is firstly successfully transformed by cadmium. • 2D-DIGE is applied to visualize the differentially expressed proteins. • RhoA plays an important role in cadmium induced malignant transformation. • Bioinformatic and experimental methods are combined to explore new mechanisms.

  17. 2D-DIGE and MALDI TOF/TOF MS analysis reveal that small GTPase signaling pathways may play an important role in cadmium-induced colon cell malignant transformation

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Jian, E-mail: lujian@ujs.edu.cn [School of Medicine, Jiangsu University, Zhenjiang 212013 (China); Institute of Life Sciences, Jiangsu University, Zhenjiang 212013 (China); Zhou, Zhongping [School of Medicine, Jiangsu University, Zhenjiang 212013 (China); Institute of Life Sciences, Jiangsu University, Zhenjiang 212013 (China); Zheng, Jianzhou [Department of Respiration Medicine, Changzhou No.2 People' s Hospital, Changzhou 213003 (China); Zhang, Zhuyi [School of Medicine, Jiangsu University, Zhenjiang 212013 (China); Institute of Life Sciences, Jiangsu University, Zhenjiang 212013 (China); Lu, Rongzhu [School of Medicine, Jiangsu University, Zhenjiang 212013 (China); Liu, Hanqing [School of Pharmacy, Jiangsu University, Zhenjiang 212013 (China); Shi, Haifeng [Institute of Life Sciences, Jiangsu University, Zhenjiang 212013 (China); Tu, Zhigang, E-mail: tuzg_ujs@ujs.edu.cn [Institute of Life Sciences, Jiangsu University, Zhenjiang 212013 (China)

    2015-10-01

    Cadmium is a toxic heavy metal present in the environment and in industrial materials. Cadmium has demonstrated carcinogenic activity that induces cell transformation, but how this occurs is unclear. We used 2D-DIGE and MALDI TOF/TOF MS combined with bioinformatics and immunoblotting to investigate the molecular mechanism of cadmium transformation. We found that small GTPases were critical for transformation. Additionally, proteins involved in mitochondrial transcription, DNA repair, and translation also had altered expression patterns in cadmium treated cells. Collectively, our results suggest that activation of small GTPases contributes to cadmium-induced transformation of colon cells. - Highlights: • Colon epithelial cell line is firstly successfully transformed by cadmium. • 2D-DIGE is applied to visualize the differentially expressed proteins. • RhoA plays an important role in cadmium induced malignant transformation. • Bioinformatic and experimental methods are combined to explore new mechanisms.

  18. Physical measurements in Marcoule reactors (1962); Mesures physiques sur les reacteurs de Marcoule (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Teste du Bailler, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    A brief description of the physical measurements in Marcoule reactors is given here. During commissioning and subsequent years of operation, various experiments ha been carried out to check design data, and improve the operating conditions and also test theoretical models for kinetic studies. (author) [French] On presente une rapide description des mesures physiques effectuees sur les reacteurs de Marcoule. Au cours du demarrage et pendant les premieres annees de fonctionnement de G-2 - G-3, de nombreuses experiences ont ete effectuees pour verifier les donnees du projet, ameliorer les conditions de fonctionnement et eprouver des modeles theoriques de calculs de cinetique. (auteur)

  19. FDG-PET identification of infected pulmonary artery conduit following tetralogy of fallot (TOF) repair

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yu Yang; Williams, Hadyn; Pucar, Darko [Dept. of Radiology, Medical College of Georgia, Augusta (United States)

    2017-03-15

    Tetralogy of Fallot (TOF) is one of the most common forms of cyanotic congenital heart disease usually managed by serial surgical repairs. The repaired prosthetic valve or conduit is susceptible to life-threatening infection. FDG-PET is an effective alternative to evaluate the source of infection when other examinations are inconclusive. We report an unusual case of an infected pulmonary artery conduit after TOF repair although the echocardiogram was negative for vegetation, which was later confirmed by surgery and pathology. The case highlights the role of FDG-PET as a problem-solving tool for potential endocarditis and cardiac device infection cases after complex cardiac surgery.

  20. FDG-PET identification of infected pulmonary artery conduit following tetralogy of fallot (TOF) repair

    International Nuclear Information System (INIS)

    Zhang, Yu Yang; Williams, Hadyn; Pucar, Darko

    2017-01-01

    Tetralogy of Fallot (TOF) is one of the most common forms of cyanotic congenital heart disease usually managed by serial surgical repairs. The repaired prosthetic valve or conduit is susceptible to life-threatening infection. FDG-PET is an effective alternative to evaluate the source of infection when other examinations are inconclusive. We report an unusual case of an infected pulmonary artery conduit after TOF repair although the echocardiogram was negative for vegetation, which was later confirmed by surgery and pathology. The case highlights the role of FDG-PET as a problem-solving tool for potential endocarditis and cardiac device infection cases after complex cardiac surgery

  1. Identifying Inhibitors of Inflammation: A Novel High-Throughput MALDI-TOF Screening Assay for Salt-Inducible Kinases (SIKs).

    Science.gov (United States)

    Heap, Rachel E; Hope, Anthony G; Pearson, Lesley-Anne; Reyskens, Kathleen M S E; McElroy, Stuart P; Hastie, C James; Porter, David W; Arthur, J Simon C; Gray, David W; Trost, Matthias

    2017-12-01

    Matrix-assisted laser desorption/ionization time-of-flight (MALDI TOF) mass spectrometry has become a promising alternative for high-throughput drug discovery as new instruments offer high speed, flexibility and sensitivity, and the ability to measure physiological substrates label free. Here we developed and applied high-throughput MALDI TOF mass spectrometry to identify inhibitors of the salt-inducible kinase (SIK) family, which are interesting drug targets in the field of inflammatory disease as they control production of the anti-inflammatory cytokine interleukin-10 (IL-10) in macrophages. Using peptide substrates in in vitro kinase assays, we can show that hit identification of the MALDI TOF kinase assay correlates with indirect ADP-Hunter kinase assays. Moreover, we can show that both techniques generate comparable IC 50 data for a number of hit compounds and known inhibitors of SIK kinases. We further take these inhibitors to a fluorescence-based cellular assay using the SIK activity-dependent translocation of CRTC3 into the nucleus, thereby providing a complete assay pipeline for the identification of SIK kinase inhibitors in vitro and in cells. Our data demonstrate that MALDI TOF mass spectrometry is fully applicable to high-throughput kinase screening, providing label-free data comparable to that of current high-throughput fluorescence assays.

  2. Testing a new NIF neutron time-of-flight detector with a bibenzyl scintillator on OMEGA.

    Science.gov (United States)

    Glebov, V Yu; Forrest, C; Knauer, J P; Pruyne, A; Romanofsky, M; Sangster, T C; Shoup, M J; Stoeckl, C; Caggiano, J A; Carman, M L; Clancy, T J; Hatarik, R; McNaney, J; Zaitseva, N P

    2012-10-01

    A new neutron time-of-flight (nTOF) detector with a bibenzyl crystal as a scintillator has been designed and manufactured for the National Ignition Facility (NIF). This detector will replace a nTOF20-Spec detector with an oxygenated xylene scintillator currently operational on the NIF to improve the areal-density measurements. In addition to areal density, the bibenzyl detector will measure the D-D and D-T neutron yield and the ion temperature of indirect- and direct-drive-implosion experiments. The design of the bibenzyl detector and results of tests on the OMEGA Laser System are presented.

  3. Rapid Classification and Identification of Microcystis aeruginosa Strains Using MALDI-TOF MS and Polygenetic Analysis.

    Directory of Open Access Journals (Sweden)

    Li-Wei Sun

    Full Text Available Matrix-assisted laser desorption-ionization-time-of-flight mass spectrometry (MALDI-TOF MS was used to establish a rapid, simple, and accurate method to differentiate among strains of Microcystis aeruginosa, one of the most prevalent types of bloom-forming cyanobacteria. M. aeruginosa NIES-843, for which a complete genome has been sequenced, was used to characterize ribosomal proteins as biomarkers and to optimize conditions for observing ribosomal proteins as major peaks in a given mass spectrum. Thirty-one of 52 ribosomal subunit proteins were detected and identified along the mass spectrum. Fifty-five strains of M. aeruginosa from different habitats were analyzed using MALDI-TOF MS; among these samples, different ribosomal protein types were observed. A polygenetic analysis was performed using an unweighted pair-group method with arithmetic means and different ribosomal protein types to classify the strains into five major clades. Two clades primarily contained toxic strains, and the other three clades contained exclusively non-toxic strains. This is the first study to differentiate cyanobacterial strains using MALDI-TOF MS.

  4. Rapid Classification and Identification of Microcystis aeruginosa Strains Using MALDI-TOF MS and Polygenetic Analysis.

    Science.gov (United States)

    Sun, Li-Wei; Jiang, Wen-Jing; Sato, Hiroaki; Kawachi, Masanobu; Lu, Xi-Wu

    2016-01-01

    Matrix-assisted laser desorption-ionization-time-of-flight mass spectrometry (MALDI-TOF MS) was used to establish a rapid, simple, and accurate method to differentiate among strains of Microcystis aeruginosa, one of the most prevalent types of bloom-forming cyanobacteria. M. aeruginosa NIES-843, for which a complete genome has been sequenced, was used to characterize ribosomal proteins as biomarkers and to optimize conditions for observing ribosomal proteins as major peaks in a given mass spectrum. Thirty-one of 52 ribosomal subunit proteins were detected and identified along the mass spectrum. Fifty-five strains of M. aeruginosa from different habitats were analyzed using MALDI-TOF MS; among these samples, different ribosomal protein types were observed. A polygenetic analysis was performed using an unweighted pair-group method with arithmetic means and different ribosomal protein types to classify the strains into five major clades. Two clades primarily contained toxic strains, and the other three clades contained exclusively non-toxic strains. This is the first study to differentiate cyanobacterial strains using MALDI-TOF MS.

  5. European neutron research prepares for future challenges

    CERN Multimedia

    Antonella Del Rosso

    2013-01-01

    Neutrons are among the fundamental building blocks of matter. Some of the processes in which they are involved are responsible for energy generation in nuclear power plants. In this context, CERN’s n_TOF and other facilities participating in the ERINDA EU-funded programme help the community integrate all the scientific efforts needed to produce high-quality nuclear data for future nuclear technologies.   The 4π calorimeter inside the n_TOF experimental area. Image courtesy of the n_TOF Collaboration. Accurate measurements of the interactions between neutrons and each of the elements present in nuclear reactors are vital tools enabling scientists to explore solutions – other than simple protected storage – for the treatment of radioactive waste deriving from a number of applications, ranging from energy production to the medical field. Particularly valuable is the contribution provided by the 13 accelerator-based neutron sources, which the ERINDA EU-funded...

  6. MALDI-TOF MS identification of anaerobic bacteria: assessment of pre-analytical variables and specimen preparation techniques.

    Science.gov (United States)

    Hsu, Yen-Michael S; Burnham, Carey-Ann D

    2014-06-01

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has emerged as a tool for identifying clinically relevant anaerobes. We evaluated the analytical performance characteristics of the Bruker Microflex with Biotyper 3.0 software system for identification of anaerobes and examined the impact of direct formic acid (FA) treatment and other pre-analytical factors on MALDI-TOF MS performance. A collection of 101 anaerobic bacteria were evaluated, including Clostridium spp., Propionibacterium spp., Fusobacterium spp., Bacteroides spp., and other anaerobic bacterial of clinical relevance. The results of our study indicate that an on-target extraction with 100% FA improves the rate of accurate identification without introducing misidentification (Panaerobes grown in suboptimal conditions, such as on selective culture media and following oxygen exposure. In conclusion, we report on a number of simple and cost-effective pre- and post-analytical modifications could enhance MALDI-TOF MS identification for anaerobic bacteria. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Contaminant screening of wastewater with HPLC-IM-qTOF-MS and LC+LC-IM-qTOF-MS using a CCS database.

    Science.gov (United States)

    Stephan, Susanne; Hippler, Joerg; Köhler, Timo; Deeb, Ahmad A; Schmidt, Torsten C; Schmitz, Oliver J

    2016-09-01

    Non-target analysis has become an important tool in the field of water analysis since a broad variety of pollutants from different sources are released to the water cycle. For identification of compounds in such complex samples, liquid chromatography coupled to high resolution mass spectrometry are often used. The introduction of ion mobility spectrometry provides an additional separation dimension and allows determining collision cross sections (CCS) of the analytes as a further physicochemical constant supporting the identification. A CCS database with more than 500 standard substances including drug-like compounds and pesticides was used for CCS data base search in this work. A non-target analysis of a wastewater sample was initially performed with high performance liquid chromatography (HPLC) coupled to an ion mobility-quadrupole-time of flight mass spectrometer (IM-qTOF-MS). A database search including exact mass (±5 ppm) and CCS (±1 %) delivered 22 different compounds. Furthermore, the same sample was analyzed with a two-dimensional LC method, called LC+LC, developed in our group for the coupling to IM-qTOF-MS. This four dimensional separation platform revealed 53 different compounds, identified over exact mass and CCS, in the examined wastewater sample. It is demonstrated that the CCS database can also help to distinguish between isobaric structures exemplified for cyclophosphamide and ifosfamide. Graphical Abstract Scheme of sample analysis and database screening.

  8. Characterization of Enterococcus species isolated from marine recreational waters by MALDI-TOF MS and Rapid ID API® 20 Strep system.

    Science.gov (United States)

    Christ, Ana Paula Guarnieri; Ramos, Solange Rodrigues; Cayô, Rodrigo; Gales, Ana Cristina; Hachich, Elayse Maria; Sato, Maria Inês Zanoli

    2017-05-15

    MALDI-TOF Mass Spectrometry Biotyping has proven to be a reliable method for identifying bacteria at the species level based on the analysis of the ribosomal proteins mass fingerprint. We evaluate the usefulness of this method to identify Enterococcus species isolated from marine recreational water at Brazilian beaches. A total of 127 Enterococcus spp. isolates were identified to species level by bioMérieux's API® 20 Strep and MALDI-TOF systems. The biochemical test identified 117/127 isolates (92%), whereas MALDI identified 100% of the isolates, with an agreement of 63% between the methods. The 16S rRNA gene sequencing of isolates with discrepant results showed that MALDI-TOF and API® correctly identified 74% and 11% of these isolates, respectively. This discrepancy probably relies on the bias of the API® has to identify clinical isolates. MALDI-TOF proved to be a feasible approach for identifying Enterococcus from environmental matrices increasing the rapidness and accuracy of results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. High intensity TOF spectrometer for cold neutrons

    International Nuclear Information System (INIS)

    Maayouf, R.M.; Abd El-Kawy, A.; Habib, N.; Adib, M.; Hamouda, I.

    1984-01-01

    This work presents a neutron time-of-flight (TOF) spectrometer developed specially for total neutron cross-section measurements at neutron energies below 5 MeV and sample's temperature varying from the liquid nitrogen one and up to 500 0 K. The spectrometer is equipped by remote control unit, designed especially, in order to move the sample in and out of the beam during the experimental measurements. The spectrometer has proved to be useful for transmission measurements at neutron energies below 5 MeV. It has a reasonable energy resolution (4.4%) and high effect to background ratio (11.1) at 5 MeV

  10. Radioelements: their detection and measurement; Les radioelements: detection et mesure

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, B. [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    A brief review of the properties of nuclear radiations is followed by a description of the basic techniques used for their detection: autoradiography, methods using the ionisation of gases (ionisation chambers, proportional counters, Geiger-Muller counters), scintillation techniques. The principles of the different methods of measurement are explained, whether they concern the activity or the energy absorbed (dosimetry). This is followed by a description of the basic techniques (4 {pi} counter, defined solid angle, {beta}-{gamma} coincidences). (author) [French] Apres un bref rappel des proprietes des rayonnements nucleaires, on decrit les techniques fondamentales employees pour leur detection: autoradiographie, procedes utilisant l'ionisation des gaz (chambres d'ionisation, compteurs proportionnels, compteurs de Geiger-Muller), technique des scintillations. On expose le principe des differentes methodes de mesure concernant soit l'activite, soit l'energie absorbee (dosimetrie). Les techniques fondamentales (compteur 4 {pi}, angle solide defini, coincidences {beta}-{gamma}) sont ensuite decrites. (auteur)

  11. Vapour pressure studies of uranium dioxide UO{sub 2} by the effusion method; Mesure de la tension de vapeur du bioxyde d'uranium UO{sub 2} par la methode d'effusion

    Energy Technology Data Exchange (ETDEWEB)

    Ohse, R W [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1965-07-01

    A high temperature apparatus for vapour pressure measurements by Knudsen effusion method is described. Sample is heated in a tungsten cell in an electronic bombardment furnace. Several critical factors affecting the accuracy of measurements such as: - temperature distribution and measurement in the effusion cell, - CLAUSING factor and molecular flow, - compatibility between cell material and sample heated, are discussed with careful attention. Vapour pressure of UO{sub 2} has been studied between 2200 and 2800 K. Experimental points fit a curve expressed by: logP{sub mm} = 12.4264 - (3.3184/T * 10{sup 4}/T) which is in good agreement with previous results of literature. (author) [French] On decrit un appareil destine a la mesure des tensions de vapeur par la methode d'effusion de KNUDSEN. L'echantillon contenu dans une cellule en tungstene est chauffe par bombardement electronique. Apres examen critique des divers facteurs affectant l'exactitude des mesures, a savoir: - homogeneite et mesure de la temperature dans la cellule d'effusion, - facteur de 'CLAUSING' et loi de distribution en cosinus des molecules effusees, - compatibilite a chaud entre le materiau de la cellule et le materiau etudie. On a procede a la mesure de la tension de vapeur de UO{sub 2} qui est relativement bien connue. Entre 2200 et 2800 K les points experimentaux se placent sur une courbe: logP{sub mm} = 12.4264 - (3.3184/T * 10{sup 4}/T) en bon accord avec les valeurs citees dans la litterature. (auteur)

  12. 16S-ARDRA and MALDI-TOF mass spectrometry as tools for identification of Lactobacillus bacteria isolated from poultry.

    Science.gov (United States)

    Dec, Marta; Puchalski, Andrzej; Urban-Chmiel, Renata; Wernicki, Andrzej

    2016-06-13

    The objective of our study is to evaluate the potential use of Amplified 16S Ribosomal DNA Restriction Analysis (16S-ARDRA) and MALDI-TOF mass spectrometry (MS) as methods for species identification of Lactobacillus strains in poultry. A total of 80 Lactobacillus strains isolated from the cloaca of chicken, geese and turkeys were identified to the species level by MALDI-TOF MS (on-plate extraction method) and 16S-ARDRA. The two techniques produced comparable classification results, some of which were additionally confirmed by sequencing of 16S rDNA. MALDI-TOF MS enabled rapid species identification but produced more than one reliable identification result for 16.25 % of examined strains (mainly of the species L. johnsonii). For 30 % of isolates intermediate log(scores) of 1.70-1.99 were obtained, indicating correct genus identification but only presumptive species identification. The 16S-ARDRA protocol was based on digestion of 16S rDNA with the restriction enzymes MseI, HinfI, MboI and AluI. This technique was able to distinguish 17 of the 19 Lactobacillus reference species tested and enabled identification of all 80 wild isolates. L. salivarius dominated among the 15 recognized species, followed by L. johnsonii and L. ingluviei. The MALDI-TOF MS and 16S-ARDRA assays are valuable tools for the identification of avian lactobacilli to the species level. MALDI-TOF MS is a fast, simple and cost-effective technique, and despite generating a high percentage of results with a log(score) Lactobacillus bacteria from different habitats.

  13. Pour mesurer le débit de l'Indus : un nouveau système de prévision ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    15 juil. 2011 ... Un partenariat de recherche entre le Pakistan et le Canada a mené au lancement d'un système de prévision très perfectionné qui promet d'aider les autorités pakistanaises à mesurer avec précision le débit de l'Indus, principale artère d'un des plus grands réseaux d'irrigation du monde.

  14. Proteomic analysis of phosphoproteins sensitive to a phosphatidylinositol 3-kinase inhibitor, ZSTK474, by using SELDI-TOF MS

    Directory of Open Access Journals (Sweden)

    Yamori Takao

    2009-03-01

    Full Text Available Abstract Background Phosphoproteins play important roles in a vast series of biological processes. Recent proteomic technologies offer the comprehensive analyses of phosphoproteins. Recently, we demonstrated that surface-enhanced laser desorption/ionization time of flight mass (SELDI-TOF MS would detect phosphoproteins quantitatively, which was a new application of SELDI-TOF MS. Results We combined immobilized metal affinity chromatography (IMAC with SELDI-TOF MS. After SELDI-TOF MS analysis of IMAC-enrichment phosphoproteins from A549 cancer cells, a series of protein peaks at 12.9, 12.8, 12.7 and 12.6 kDa was obtained in a mass spectrum. The peak intensities of these proteins decreased after a phosphatase treatment and, interestingly, they also decreased when the cells were pre-treated with a novel phosphatidylinositol 3-kinase (PI3K inhibitor, ZSTK474, suggesting that these proteins were ZSTK474-sensitive phosphoproteins. Identity of the phosphoproteins, which were predicted as the multi-phosphorylated forms of 4E-binding protein 1 (4E-BP1 with the aid of TagIdent algorithm, was confirmed by immunoprecipitation and subsequent SELDI-TOF MS analysis. 4E-BP1 is a downstream component of the PI3K/Akt/mTOR pathway and it regulates protein synthesis. We also investigated the effect of ZSTK474 on 4E-BP1 phosphorylation using phospho-specific antibodies. ZSTK474, which have little inhibitory activity for mTOR, inhibited phosphorylation of Ser65, Thr70 and Thr37/46 in 4E-BP1. In contrast, rapamycin, an inhibitor of mTOR, blocked phosphorylation only of Ser65 and Thr70. These results suggest that ZSTK474 and rapamycin inhibited the phosphorylation of 4E-BP1 in a different manner. Conclusion We identified a group of ZSTK474-sensitive phosphoproteins as the multi-phosphorylated form of 4E-BP1 by combining IMAC, SELDI-TOF MS and antibodies.

  15. International intercomparison of fluence of fast neutrons using 115In(n,γ) activation

    International Nuclear Information System (INIS)

    Lesiecki, H.; Cosack, M.

    1985-07-01

    The Physikalisch-Technische Bundesanstalt (PTB) has participated in an international intercomparison of fluence measurements of fast neutrons. This was organized under the auspices of the ''Comite Consultatif pour les Etalons de Mesure des Rayonnements Ionisants (CCEMRI)'', Sect. 3 (Mesures Neutronique). The National Physical Laboratory (NPL), Teddington, UK volunteered to assume responsibility for the experimental realization and final evaluation. This report deals with the measurements performed at the PTB for the neutron fluence intercomparison at neutron energies of Esub(n) = 144 keV and 570 keV which was based on the 115 In(n,γ) 116 Insup(m) reaction. The count rate of a 4πβ-counter which had to be used to determine the activation of the In sample was to be compared with the neutron fluence by which the sample was irradiated. A description of the neutron production, the fluence determination, the 4πβ-counting, and the evaluation of the results will be given. (orig.) [de

  16. Rapid mass spectrometric analysis of 15N-Leu incorporation fidelity during preparation of specifically labeled NMR samples

    DEFF Research Database (Denmark)

    Truhlar, Stephanie M E; Cervantes, Carla F; Torpey, Justin W

    2008-01-01

    . MALDI TOF-TOF MS/MS data provide additional information that shows where the "extra" (15)N labels are incorporated, which can be useful in confirming ambiguous assignments. The described procedure provides a rapid technique to monitor the fidelity of selective labeling that does not require a lot...

  17. Characterisation of oligosaccharides in vegetables by HPLC and MALDI-TOF MS

    Czech Academy of Sciences Publication Activity Database

    Štikarovská, M.; Chmelík, Josef

    96(S), - (2002), s. S189-S191 ISSN 0009-2770. [Meeting of Chemistry & Life /2./. Brno, 10.09.2002-11.09.2002] Institutional research plan: CEZ:AV0Z4031919 Keywords : oligosaccharides * HPLC * MALDI-TOF-MS Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.336, year: 2002

  18. Solid-supported enzymatic synthesis of pectic oligogalacturonides and their analysis by MALDI-TOF mass spectrometry

    DEFF Research Database (Denmark)

    Guillaumie, Fanny; Sterling, J.D.; Jensen, K.J.

    2003-01-01

    Solid-phase biosynthetic reactions, followed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis (MALDI-TOF), was used to gain insight into the biosynthesis of pectin oligomers. Sepharose supports bearing long pectic oligogalacturonides (OGAs) anchored through...... into the liquid phases by MALDI-TOF mass spectrometry. In time course studies conducted with an immobilized (alpha-D-GalA)(14) and limiting amounts of the glycosyl donor, the predominant product was an OGA extended by one GalA residue at the non-reducing end (i.e., (GalA)(15)). When UDP-GalA was added...

  19. Qualitative and quantitative analysis of pharmaceutical compounds by MALDI-TOF mass spectrometry.

    NARCIS (Netherlands)

    Kampen, J.J. van; Burgers, P.C.; Groot, R. de; Luider, T.M.

    2006-01-01

    In this report, we discuss key issues for the successful application of MALDI-TOF mass spectrometry to quantify drugs. These include choice and preparation of matrix, nature of cationization agent, automation, and data analysis procedures. The high molecular weight matrix

  20. Fast flux measurements by means of threshold detectors on the reactor 'Melusine'; Mesures de flux rapides a l'aide de detecteurs a seuil sur le reacteur 'Melusine'

    Energy Technology Data Exchange (ETDEWEB)

    Leger, P; Sautiez, B [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    Using existing data on the (n,p) and (n,{alpha}) threshold reactions we have carried out fast flux measurements on the swimming pool type reactor 'Melusine'. Four common elements: P, S, Mg, Al were chosen because from the point of view of fast spectrum analysis they represent a fairly good energy range from 2.4 MeV to 8 MeV. The fission flux value found in the central element at a power of 1 MW is 1.4 x 10{sup 13} n/cm{sup 2}/s {+-} 0.14. (author) [French] A l'aide des donnees actuelles sur les reactions a seuil (n,p) et (n,{alpha}) nous avons realise des mesures de flux rapide dans le reacteur du type piscine 'Melusine'. Quatre corps courants: P, S, Mg, Al, ont ete choisis parce qu'ils constituent au point de vue de l'analyse du spectre rapide un assez bon etalement en energie de 2,4 MeV A 8 MeV. La valeur du flux de fission trouve dans l'element central a une puissance de 1 MW est de 1,4.10{sup 13} n/cm{sup 2}/s {+-} 0,14. (auteur)

  1. Automatic device for measuring {beta}-emitting sources: P.A.P.A. {beta}-meters; Dispositif automatique pour la mesure de sources emettrices de rayonnement {beta}: P.A.P.A. {beta} metres

    Energy Technology Data Exchange (ETDEWEB)

    Colomer, J; Valentin, M [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    The apparatus described is designed for measuring {beta}-emitting elements by the absorption method; it is suitable for carrying out a large number of routine analyses. A mechanical device pushes an aluminium absorption set automatically between the source and the detector; the movement is programmed for cutting on and off by a transistorized electronic unit, with printing out and punching of the results on tape; then this can be mathematically processed by a computer (tracing of absorption spectra, extrapolation and calculation of the activity). The detector is either a {beta}-probe or a proportional counter with a specially designed loop. For routine measurements, the accuracy obtained, with all corrections made, is from 5 to 8 per cent; the reproducibility is about 2 per cent. (authors) [French] L'appareillage decrit est destine aux mesures des elements emetteurs {beta} par la methode d'absorption et il permet d'effectuer, en routine, un nombre important de mesures. Un ensemble mecanique effectue le passage automatique, sous vide primaire, d'un jeu d'absorption en aluminium entre la source et le detecteur, ce passage est programme en pre-temps ou pre-coup par un ensemble electronique a transistors, avec impression et perforation sur bandes des resultats des mesures pour traitement mathematique par un ordinateur (trace du spectre d'absorption, extrapolation et calcul d'activite). Le detecteur est soit une sonde {beta}, soit un compteur proportionnel a boucle specialement realise. Sur des mesures de routine, la precision obtenue, toutes corrections effectuees, est de 5 a 8 pour cent et la reproductibilite de l'ordre de 2 pour cent. (auteur)

  2. Yeast identification by sequencing, biochemical kits, MALDI-TOF MS and rep-PCR DNA fingerprinting.

    Science.gov (United States)

    Zhao, Ying; Tsang, Chi-Ching; Xiao, Meng; Chan, Jasper F W; Lau, Susanna K P; Kong, Fanrong; Xu, Yingchun; Woo, Patrick C Y

    2017-12-08

    No study has comprehensively evaluated the performance of 28S nrDNA and ITS sequencing, commercial biochemical test kits, MALDI-TOF MS platforms, and the emerging rep-PCR DNA fingerprinting technology using a cohort of yeast strains collected from a clinical microbiology laboratory. In this study, using 71 clinically important yeast isolates (excluding Candida albicans) collected from a single centre, we determined the concordance of 28S nrDNA and ITS sequencing and evaluated the performance of two commercial test kits, two MALDI-TOF MS platforms, and rep-PCR DNA fingerprinting. 28S nrDNA and ITS sequencing showed complete agreement on the identities of the 71 isolates. Using sequencing results as the standard, 78.9% and 71.8% isolates were correctly identified using the API 20C AUX and Vitek 2 YST ID Card systems, respectively; and 90.1% and 80.3% isolates were correctly identified using the Bruker and Vitek MALDI-TOF MS platforms, respectively. Of the 18 strains belonging to the Candida parapsilosis species complex tested by DiversiLab automated rep-PCR DNA fingerprinting, all were identified only as Candida parapsilosis with similarities ≥93.2%, indicating the misidentification of Candida metapsilosis and Candida orthopsilosis. However, hierarchical cluster analysis of the rep-PCR DNA fingerprints of these three species within this species complex formed three different discrete clusters, indicating that this technology can potentially differentiate the three species. To achieve higher accuracies of identification, the databases of commercial biochemical test kits, MALDI-TOF MS platforms, and DiversiLab automated rep-PCR DNA fingerprinting needs further enrichment, particularly for uncommonly encountered yeast species. © The Author 2017. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Outcomes of Pulmonary Valve Replacement for Correction Pulmonary Insufficiency after Primary Repair of Tetralogy of Fallot (TOF)

    OpenAIRE

    Mohammad Abbassi Teshnisi; Aliasghar Moeinipour; Hamid Hoseinikhah; Seyedeh Zahra Aemmi; Shahla Shirin Bahador; Nahid Zirak

    2016-01-01

    Background Total correction of Tetralogy of Fallot (TOF) anomaly in early childhood has been practiced in many centers with good results, but in some of patients after few years sever Pulmonary valve insufficiency occurred. Materials and Methods At a cross- sectional study from January 2015 to January 2016, 10 patients who had history of primary repair of TOF with free pulmonary insufficiency (PI) that underwent of pulmonary valve replacement (PVR) with bioprosthetic valves were evaluated. Re...

  4. A new detector for the measurement of neutron flux in nuclear reactors; Nouvelle methode de mesure des flux de neutrons dans les reacteurs atomiques

    Energy Technology Data Exchange (ETDEWEB)

    Koch, L; Labeyrie, J; Tarassenko, S [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The detector described is designed for the instantaneous measurement of thermal neutron fluxes, in the presence of high {gamma} ray activity; this detector can withstand temperatures as high as 500 deg. C. It is based on the following principle: radioactive atoms resulting from heavy-nucleus fission are carried by a gas flow to a detector recording their {beta} and {gamma} disintegration. Thermal neutron fluxes as low as few neutrons per cm{sup 2} per second can be measured. This detector may be used to control a nuclear reactor, to plot the thermal flux distribution with an excellent definition (1 mm{sup 2}) for fluxes higher than 10{sup 8} n/cm{sup 2}/s. The time response of the system to a sharp variation of flux is limited, in case of large fluxes, to the transit time of the gas flow between the fission product emitter and the detector; of the order of one tenth of a sec per meter of piping. The detector may also be applied for spectroscopy of fission products eider than 0,1 s. (author)Fren. [French] On decrit un appareil permettant la mesure instantanee des flux de neutrons thermiques accompagnes de flux intenses de rayons {gamma} et situes dans des enceintes pouvant etre portees a des temperatures superieures a 500 deg. C. On utilise la radioactivite des atomes resultant de la fission des noyaux lourds; ces atomes sont entraines par un courant gazeux vers un detecteur de radioactivite qui enregistre leurs desintegrations {beta} et {gamma}. On peut mesurer des flux partir de quelques neutrons thermiques par cm{sup 2} et par seconde. L'appareil permet de suivre la puissance d'un reacteur atomique, de tracer des cartes de densite de neutrons avec une tres bonne definition (1 mm{sup 2}) dans le cas de flux superieurs a 10{sup 8} cm{sup 2}/s. Le temps de reponse du systeme a une variation du flux de neutrons est limite, poes flux importants, par le temps de transit du gaz entre l'emetteur de produits de fission et le detecteur: soit quelques dizaines de

  5. MALDI-TOF mass spectrometry for rapid diagnosis of postoperative endophthalmitis.

    Science.gov (United States)

    Mailhac, Adriane; Durand, Harmonie; Boisset, Sandrine; Maubon, Danièle; Berger, Francois; Maurin, Max; Chiquet, Christophe; Bidart, Marie

    2017-01-30

    This study describes an innovative strategy for rapid detection and identification of bacteria causing endophthalmitis, combining the use of an automated blood culture system with MALDI-TOF mass spectrometry methodology. Using this protocol, we could identify 96% of 45 bacterial strains isolated from vitreous samples collected in acute post-operative endophthalmitis patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Chemical and structural analysis of the bone-implant interface by TOF-SIMS, SEM, FIB and TEM: Experimental study in animal

    International Nuclear Information System (INIS)

    Palmquist, Anders; Emanuelsson, Lena; Sjövall, Peter

    2012-01-01

    Although bone-anchored implants are widely used in reconstructive medicine, the mechanism of osseointegration is still not fully understood. Novel analytical tools are needed to further understand this process, where both the chemical and structural aspects of the bone-implant interface are important. The aim of this study was to evaluate the advantages of combining time-of-flight secondary ion mass spectroscopy (TOF-SIMS) with optical (LM), scanning (SEM) and transmission electron microscopy (TEM) techniques for studying the bone-implant interface of bone-anchored implants. Laser-modified titanium implants with surrounded bone retrieved after 8 weeks healing in rabbit were dehydrated and resin embedded. Three types of sample preparation were studied to evaluate the information gained by combining TOF-SIMS, SEM, FIB and TEM. The results show that imaging TOF-SIMS can provide detailed chemical information, which in combination with structural information from microscopy methods provide a more complete characterization of anatomical structures at the bone-implant interface. By investigating various sample preparation techniques, it is shown that grinded cross section samples can be used for chemical imaging using TOF-SIMS, if careful consideration of potential preparation artifacts is taken into account. TOF-SIMS analysis of FIB-prepared bone/implant cross section samples show distinct areas corresponding to bone tissue and implant with a sharp interface, although without chemical information about the organic components.

  7. In-beam measurements of the HADES-TOF RPC wall

    Czech Academy of Sciences Publication Activity Database

    Blanco, A.; Cabanelas, P.; Belver, D.; Castro, E.; Díaz, J.; Fonte, P.; Gil, A.; Garzón, J.A.; Gonzalez-Diaz, D.; Heinz, T.; Koenig, W.; Lopes, L.; Muentz, C.; Palka, M.; Pietraszko, J.; Rustamov, A.; Schwab, E.; Sobolev, Yuri, G.; Tarantola, A.; Teilab, K.; Traxler, M.; Trebacz, R.; Wuestenfeld, J.; Yurevich, S.

    2009-01-01

    Roč. 602, č. 3 (2009), s. 691-695 ISSN 0168-9002. [9th International Workshop on Resistive Plate Chambers and Related Detectors. Bombay, 13.02.2008-16.02.2008] R&D Projects: GA AV ČR IAA100480803; GA MŠk LC07050 Institutional research plan: CEZ:AV0Z10480505 Keywords : Gaseous detectors * Timing * TOF Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.317, year: 2009

  8. Custom database development and biomarker discovery methods for MALDI-TOF mass spectrometry-based identification of high-consequence bacterial pathogens.

    Science.gov (United States)

    Tracz, Dobryan M; Tyler, Andrea D; Cunningham, Ian; Antonation, Kym S; Corbett, Cindi R

    2017-03-01

    A high-quality custom database of MALDI-TOF mass spectral profiles was developed with the goal of improving clinical diagnostic identification of high-consequence bacterial pathogens. A biomarker discovery method is presented for identifying and evaluating MALDI-TOF MS spectra to potentially differentiate biothreat bacteria from less-pathogenic near-neighbour species. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  9. Measurement of resonance absorption integrals; Mesure des integrales de resonance d'absorption

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, R [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1964-07-01

    The measurements are carried out by the pile oscillator technique, without cadmium filter., in a spectrum rich in epithermal neutrons. The values are extrapolated to infinite dilution and corrected for the junction function. For the excess on the part in l/V, the following values are found: In: 3200 {+-} 70 b; Hf: 2080 {+-} 50; Ag: 670 {+-} 20; Co: 50 {+-} 5; Cs: 450 {+-} 15; Th: 87 {+-} 4. (author) [French] Les mesures sont effectuees par la methode d'oscillation, sans filtre de cadmium, dans un spectre riche en neutrons epithermiques. Les valeurs sont extrapolees a la dilution infinie et corrigees de la fonction de jonction. On trouve, pour l'exces sur la partie en l/v: In: 3200 {+-} 70 b; Hf: 2080 {+-} 50; Ag: 670 {+-} 20; Co: 50 {+-} 5; Cs: 450 {+-} 15; Th: 87 {+-} 4. (auteur)

  10. Use of ribosomal proteins as biomarkers for identification of Flavobacterium psychrophilum by MALDI-TOF mass spectrometry.

    Science.gov (United States)

    Fernández-Álvarez, Clara; Torres-Corral, Yolanda; Santos, Ysabel

    2018-01-06

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF-MS) is a rapid methodology for identification of bacteria that is increasingly used in diagnostic laboratories. This work aimed at evaluating the potential of MALDI-TOF-MS for identification of the main serotypes of Flavobacterium psychrophilum isolated from salmonids, and its discrimination from closely related Flavobacterium spp. A mass spectra library was constructed by analysing 70 F. psychrophilum strains representing the serotypes O1, O2a, O2b and O3, including reference and clinical isolates. Peak mass lists were examined using the Mass-Up software for the detection of potential biomarkers, similarity and cluster analysis. Fourteen species-identifying biomarkers were detected in all the F. psychrophilum isolates tested, moreover, sets of serotype-identifying biomarkers ions were selected. F. psychrophilum-specific biomarkers were identified as ribosomal proteins by matching with protein databases. Furthermore, sequence variation corresponding to amino acid exchanges in several biomarker proteins were tentatively assigned. Closely related Flavobacterium species (F. flevense, F. succinicans, F. columnare, F. branchiophilum and F. johnsoniae) could be differentiated from F. psychrophilum by defining species identifying biomarkers and hierarchical cluster analysis. These results demonstrated that MALDI-TOF spectrometry represents a powerful tool for an accurate identification of the fish pathogen F. psychrophilum as well as for epidemiological studies. The results obtained in this study demonstrated that MALDI-TOF mass spectrometry represents a powerful tool that can be used by diagnostic laboratories for rapid identification of the fish pathogen Flavobacterium psychrophilum and its differentiation from other Flavobacterium-related species. Analysis of mass peak lists revealed the potential of the MALDI-TOF technique to identify epidemiologically important serotypes affecting

  11. MALDI-TOF MS is more accurate than VITEK II ANC card and API Rapid ID 32 A system for the identification of Clostridium species.

    Science.gov (United States)

    Kim, Young Jin; Kim, Si Hyun; Park, Hyun-Jung; Park, Hae-Geun; Park, Dongchul; Song, Sae Am; Lee, Hee Joo; Yong, Dongeun; Choi, Jun Yong; Kook, Joong-Ki; Kim, Hye Ran; Shin, Jeong Hwan

    2016-08-01

    All 50 Clostridium difficile strains were definitely identified by Vitek2 system, Rapid ID 32A system, and MALDI-TOF. For 18 non-difficile Clostridium strains, the identification results were correct in 0, 2, and 17 strains by Vitek2, Rapid ID 32A, and MALDI-TOF, respectively. MALDI-TOF could be used as the primary tool for identification of Clostridium species. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Identification of Brucella by MALDI-TOF mass spectrometry. Fast and reliable identification from agar plates and blood cultures.

    Directory of Open Access Journals (Sweden)

    Laura Ferreira

    Full Text Available BACKGROUND: MALDI-TOF mass spectrometry (MS is a reliable method for bacteria identification. Some databases used for this purpose lack reference profiles for Brucella species, which is still an important pathogen in wide areas around the world. We report the creation of profiles for MALDI-TOF Biotyper 2.0 database (Bruker Daltonics, Germany and their usefulness for identifying brucellae from culture plates and blood cultures. METHODOLOGY/PRINCIPAL FINDINGS: We created MALDI Biotyper 2.0 profiles for type strains belonging to B. melitensis biotypes 1, 2 and 3; B. abortus biotypes 1, 2, 5 and 9; B. suis, B. canis, B ceti and B. pinnipedialis. Then, 131 clinical isolates grown on plate cultures were used in triplicate to check identification. Identification at genus level was always correct, although in most cases the three replicates reported different identification at species level. Simulated blood cultures were performed with type strains belonging to the main human pathogenic species (B. melitensis, B. abortus, B. suis and B. canis, and studied by MALDI-TOF MS in triplicate. Identification at genus level was always correct. CONCLUSIONS/SIGNIFICANCE: MALDI-TOF MS is reliable for Brucella identification to the genus level from culture plates and directly from blood culture bottles.

  13. Screening for illicit and medicinal drugs in whole blood using fully automated SPE and UHPLC-TOF-MS with data-independent acquisition

    DEFF Research Database (Denmark)

    Pedersen, Anders Just; Dalsgaard, Petur Weihe; Rode, Andrej Jaroslav

    2013-01-01

    , butylone, cathine, fentanyl, LSD, mCPP, MDPV, mephedrone, 4-methylamphetamine, p-fluoroamphetamine, and PMMA. In conclusion, using UHPLC-TOF-MS screening with data-independent acquisition resulted in detection of common drugs of abuse as well as new designer-drugs and more rarely occurring drugs. Thus, TOF...

  14. Rapid analysis of fungal cultures and dried figs for secondary metabolites by LC/TOF-MS

    Energy Technology Data Exchange (ETDEWEB)

    Senyuva, Hamide Z. [Ankara Test and Analysis Laboratory, Scientific and Technological Research Council of Turkey, Ankara 06330 (Turkey)], E-mail: hamide.senyuva@tubitak.gov.tr; Gilbert, John [Central Science Laboratory, Sand Hutton, York YO41 1LZ (United Kingdom); Oztuerkoglu, Sebnem [Ankara Test and Analysis Laboratory, Scientific and Technological Research Council of Turkey, Ankara 06330 (Turkey)

    2008-06-09

    A liquid chromatography-time-of-flight mass spectrometry (LC/TOF-MS) method has been developed for profiling fungal metabolites. The performance of the procedure in terms of mass accuracy, selectivity (specificity) and repeatability was established by spiking aflatoxins, ochratoxins, trichothecenes and other metabolites into blank growth media. After extracting, and carrying out LC/TOF-MS analysis, the standards were correctly identified by searching a specially constructed database of 465 secondary metabolites. To demonstrate the viability of this approach 11 toxigenic and four non-toxigenic fungi from reference collections were grown on various media, for 7-14 days. The method was also applied to two toxigenic fungi, A. flavus (200-138) and A. parasiticus (2999-465) grown on gamma radiation sterilised dried figs, for 7-14 days. The fungal hyphae plus a portion of growth media or portions of dried figs were solvent extracted and analysed by LC/TOF-MS using a rapid resolution microbore LC column. Data processing based on cluster analysis, showed that electrospray ionization (ESI)-TOF-MS could be used to unequivocally identify metabolites in crude extracts. Using the elemental metabolite database, it was demonstrated that from culture collection isolates, anticipated metabolites. The speed and simplicity of the method has meant that levels of these metabolites could be monitored daily in sterilised figs. Over a 14-day period, levels of aflatoxins and kojic acid maximised at 5-6 days, whilst levels of 5-methoxysterigmatocystin remained relatively constant. In addition to the known metabolites expected to be produced by these fungi, roquefortine A, fumagillin, fumigaclavine B, malformins (peptides), aspergillic acid, nigragillin, terrein, terrestric acid and penicillic acid were also identified.

  15. Rapid and reliable discrimination between Shigella species and Escherichia coli using MALDI-TOF mass spectrometry.

    Science.gov (United States)

    Paauw, Armand; Jonker, Debby; Roeselers, Guus; Heng, Jonathan M E; Mars-Groenendijk, Roos H; Trip, Hein; Molhoek, E Margo; Jansen, Hugo-Jan; van der Plas, Jan; de Jong, Ad L; Majchrzykiewicz-Koehorst, Joanna A; Speksnijder, Arjen G C L

    2015-01-01

    E. coli-Shigella species are a cryptic group of bacteria in which the Shigella species are distributed within the phylogenetic tree of E. coli. The nomenclature is historically based and the discrimination of these genera developed as a result of the epidemiological need to identify the cause of shigellosis, a severe disease caused by Shigella species. For these reasons, this incorrect classification of shigellae persists to date, and the ability to rapidly characterize E. coli and Shigella species remains highly desirable. Until recently, existing matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) assays used to identify bacteria could not discriminate between E. coli and Shigella species. Here we present a rapid classification method for the E. coli-Shigella phylogroup based on MALDI-TOF MS which is supported by genetic analysis. E. coli and Shigella isolates were collected and genetically characterized by MLVA. A custom reference library for MALDI-TOF MS that represents the genetic diversity of E. coli and Shigella strains was developed. Characterization of E. coli and Shigella species is based on an approach with Biotyper software. Using this reference library it was possible to distinguish between Shigella species and E. coli. Of the 180 isolates tested, 94.4% were correctly classified as E. coli or shigellae. The results of four (2.2%) isolates could not be interpreted and six (3.3%) isolates were classified incorrectly. The custom library extends the existing MALDI-TOF MS method for species determination by enabling rapid and accurate discrimination between Shigella species and E. coli. Copyright © 2015 Elsevier GmbH. All rights reserved.

  16. Rapid Identification of Microorganisms from Positive Blood Culture by MALDI-TOF MS After Short-Term Incubation on Solid Medium.

    Science.gov (United States)

    Curtoni, Antonio; Cipriani, Raffaella; Marra, Elisa Simona; Barbui, Anna Maria; Cavallo, Rossana; Costa, Cristina

    2017-01-01

    Matrix-assisted laser-desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a useful tool for rapid identification of microorganisms. Unfortunately, its direct application to positive blood culture is still lacking standardized procedures. In this study, we evaluated an easy- and rapid-to-perform protocol for MALDI-TOF MS direct identification of microorganisms from positive blood culture after a short-term incubation on solid medium. This protocol was used to evaluate direct identification of microorganisms from 162 positive monomicrobial blood cultures; at different incubation times (3, 5, 24 h), MALDI-TOF MS assay was performed from the growing microorganism patina. Overall, MALDI-TOF MS concordance with conventional methods at species level was 60.5, 80.2, and 93.8% at 3, 5, and 24 h, respectively. Considering only bacteria, the identification performances at species level were 64.1, 85.0, and 94.1% at 3, 5, and 24 h, respectively. This protocol applied to a commercially available MS typing system may represent, a fast and powerful diagnostic tool for pathogen direct identification and for a promptly and pathogen-driven antimicrobial therapy in selected cases.

  17. Implications of\tenhanced\teffectiveness\tof\tvincristine\tsulfate/ε-viniferin combination\tcompared\tto\tvincristine\tsulfate\tonly\ton\tHepG2\tcells

    Directory of Open Access Journals (Sweden)

    Filiz\tÖzdemir

    2016-12-01

    Full Text Available Objective: This\tstudy\twas\tdesigned\tto\tinvestigate\tthe\teffects\tof\tε-viniferin\t(ε-VNF\ton\tthe\tmitochondrial\tpathway\tof\tapoptosis and\ton\tlate\tapoptosis\tin\tHepG2\tcell\tlines.\tTo\tobserve\tthese\teffects,\tε-VNF\tand\tvincristine\tsulfate\t(VNC,\tanti-cancer\tdrugs\tused for\ttreatment\ton\tHepG2\tcells,\twere\tadministered\teither\talone\tor\tin\tcombination\tat\tdifferent\ttime\tintervals. Methods:\tMitochondrial\tmembrane\tpotential\tchanges\tin\tthe\tcells\t(ΔΨm\twere\tevaluated\tusing\tcationic\tdye\tJC-1,\twhile\tBax,\tBcl- 2\texpression\tlevels\twith\tRT-PCR\tand\tcaspase-3\tactivity\twere\tanalyzed\tusing\ta\tkit.\tFor\tdetection\tof\tapoptotic\tactivity,\tan\tin\tsitu TUNEL\tassay\twas\tperformed. Results: When 98.3µM ε-VNF, 52.5µM VNC and the 11.25+15.8µM VNC+ε-VNF combination were compared with the control group,\tΔΨm\tchanges\tat\tthe\t6th\thour\twere\tfound\tto\tbe\t19.5%,\t5.5%,\t24.6%,\tand\t3.5%\t,\trespectively.\tThese\tfinding\tshow\tthat\tthe combination\tgroup\t(24.6%\tresulted\tin\tearly\tapoptosis\tof\tthe\tcell\tat\tthe\t6th\thour.\tBax\tmRNA\texpression\tincreased\tat\tthe\t24th hour in the VNC+ε-VNF group compared to control group (160%, and caspase-3 activation increased in the 1.25+15.8 µM[VNC+ε-VNF]\tgroup\tcompared\tto\tthe\tcontrol\tgroup\tat\tthe\t48th\thour.\tThe\tdetection\tof\tDNA\tfragments\tin\tHepG2\tcells\twithin 24\thours\tsuggests\tdirect\tapoptosis. Conclusion: These findings demonstrate that the doses administered to the VNC+ε-VNF combination group\twere\tlower than those\tadministered\tto\tgroups\tusing\tone\tagent\talone\t(e.g.\tVNC,\tthe\tresults\tof\twhich\treduce\tthe\tpossibility\tof\tadministering\ttoxic doses.

  18. Assessment of various parameters to improve MALDI-TOF MS reference spectra libraries constructed for the routine identification of filamentous fungi.

    Science.gov (United States)

    Normand, Anne-Cécile; Cassagne, Carole; Ranque, Stéphane; L'ollivier, Coralie; Fourquet, Patrick; Roesems, Sam; Hendrickx, Marijke; Piarroux, Renaud

    2013-04-08

    The poor reproducibility of matrix-assisted desorption/ionization time-of-flight (MALDI-TOF) spectra limits the effectiveness of the MALDI-TOF MS-based identification of filamentous fungi with highly heterogeneous phenotypes in routine clinical laboratories. This study aimed to enhance the MALDI-TOF MS-based identification of filamentous fungi by assessing several architectures of reference spectrum libraries. We established reference spectrum libraries that included 30 filamentous fungus species with various architectures characterized by distinct combinations of the following: i) technical replicates, i.e., the number of analyzed deposits for each culture used to build a reference meta-spectrum (RMS); ii) biological replicates, i.e., the number of RMS derived from the distinct subculture of each strain; and iii) the number of distinct strains of a given species. We then compared the effectiveness of each library in the identification of 200 prospectively collected clinical isolates, including 38 species in 28 genera.Identification effectiveness was improved by increasing the number of both RMS per strain (plibrary markedly improved the effectiveness of the MALDI-TOF MS-based identification of clinical filamentous fungi.

  19. Profiling LC-DAD-ESI-TOF MS method for the determination of phenolic metabolites from avocado (Persea americana).

    Science.gov (United States)

    Hurtado-Fernández, Elena; Carrasco-Pancorbo, Alegría; Fernández-Gutiérrez, Alberto

    2011-03-23

    A powerful HPLC-DAD-ESI-TOF MS method was established for the efficient identification of the chemical constituents in the methanolic extracts of avocado (Persea americana). Separation and detection conditions were optimized by using a standard mix containing 39 compounds belonging to phenolic acids and different categories of flavonoids, analytes that could be potentially present in the avocado extracts. Optimum LC separation was achieved on a Zorbax Eclipse Plus C18 analytical column (4.6×150 mm, 1.8 μm particle size) by gradient elution with water+acetic acid (0.5%) and acetonitrile as mobile phases, at a flow rate of 1.6 mL/min. The detection was carried out by ultraviolet-visible absorption and ESI-TOF MS. The developed method was applied to the study of 3 different varieties of avocado, and 17 compounds were unequivocally identified with standards. Moreover, around 25 analytes were tentatively identified by taking into account the accuracy and isotopic information provided by TOF MS.

  20. Toxicological screening of basic drugs in whole blood using UPLC-TOF-MS

    DEFF Research Database (Denmark)

    Dalsgaard, Petur Weihe; Rasmussen, Brian Schou; Müller, Irene Breum

    2012-01-01

    Ultra performance liquid chromatography (UPLC) coupled with time-of-flight (TOF) mass spectrometry (MS) was established for toxicological screening of basic drugs in whole blood and tested on authentic samples. Whole blood samples (0.2 ml) were extracted using a Gilson apparatus equipped with Bond...