Sample records for transducers
from WorldWideScience.org

Sample records 1 - 20 shown. Select sample records:



1

Transdutores potenciométricos a base de polímeros condutores: aplicações analíticas/ Potentiometric transducers based in conducting polymers: analytical applications

Rover Júnior, Laércio; Oliveira Neto, Graciliano de; Kubota, Lauro Tatsuo
1997-10-01

Resumo em inglês A review is given about the most relevant advances on the analytical applications of conducting polymers in potentiometric sensors. These organic polymers represent a new class of materials with conducting properties due to its doping by ions. Several polymers already were synthesized such as polypyrrole, polyaniline, polythiophene, among others. Particular attention is devoted to the main advantages supplied by ion selective electrodes and gas sensors using conducting po (mais) lymers, as well as the incorporation of bioactive elements in these polymers for the construction of biosensors. The correlation between structure, stability and ability to ion exchange of some conducting polymers applied as potentiometric transducers, is discussed.

Scientific Electronic Library Online (Portuguese)

2

Uso de transdutores de fluxo de calor no estudo da transferência de calor em alimentos embalados/ The use of heat flux transducers to study heat transfer in canned foods

Carciofi, B.; Güths, S.; Laurindo, J. B.
2002-12-01

Resumo em português A densidade de fluxo de calor que atravessa uma superfície é classicamente determinada mediante a medição das temperaturas apropriadas e da aplicação da Lei de Fourier. Uma alternativa a esse procedimento é a utilização de transdutores de fluxo de calor, os quais geram um sinal elétrico proporcional ao fluxo térmico que os atravessa. Neste trabalho, processos de aquecimento e de resfriamento de alimentos foram estudados em laboratório, utilizando-se um recipie (mais) nte de vidro cilíndrico para simular uma embalagem. Dois transdutores de fluxo de calor a gradiente tangencial foram previamente instalados no recipiente, revestindo completamente a superfície lateral do mesmo. O recipiente contendo a amostra foi inserido em banho de água circulante à temperatura constante. Os sinais fornecidos pelos transdutores e por termopares inseridos no interior do recipiente foram registrados por um sistema de aquisição de dados computadorizado. Os resultados obtidos com o uso dos transdutores foram comparados com aqueles obtidos através de balanços de energia realizados a partir dos dados experimentais de evolução temporal das temperaturas da amostra junto à superfície interna da embalagem e no centro da mesma. A comparação mostrou que os transdutores de fluxo de calor a gradiente tangencial puderam determinar os fluxos de calor, com tempo de resposta característico dos termopares. Os resultados apresentados mostraram a viabilidade de utilização desses fluxímetros no estudo não destrutivo e não invasivo dos processos de aquecimento e de resfriamento de alimentos, fornecendo informações complementares àquelas obtidas pelo uso de termopares instalados no interior da embalagem. Resumo em inglês Heat flux determination in thermal processes is classically carried out by appropriate temperature measurements and the application of the Fourier Law. An alternative to this procedure is to determine the heat flux that crosses a surface using heat flux transducers, thus producing heat flux dependent signals. In this work, heating and cooling processes of foods were studied in the laboratory using a cylindrical glass container with the external surface covered by two heat (mais) flux meters. Water, maintained at a constant temperature by a thermostatically controlled bath, was circulated within an external jacket to promote heating or cooling of the sample-container system. The signals provided by the transducers and thermocouples placed inside the container were registered by an on-line data acquisition system. Comparison of the results from the heat flux meters with those calculated by using the sample temperature histories and energy balances in the container-sample system showed to be in good agreement with each other. The time-response of the heat flux meters had the same magnitude as those obtained by the thermocouples. The results showed that heat transducers could be used to carry out non-destructive heat flux measurements in heating and cooling processes of foods, supplying additional information to those obtained by thermocouples installed inside the container.

Scientific Electronic Library Online (Portuguese)

3

Análise unidimensional de transdutores piezelétricos baseada no teorema de Thévenin/ One-dimensional analysis of piezoelectric transducers based on Thévenin theorem

Arnold, Francisco J
2009-12-01

Resumo em português Neste trabalho é apresentado um método de análise de transdutores piezelétricos baseado numa simplificação do circuito elétrico equivalente de Mason. Empregou-se uma adaptação do teorema de Thévenin para analisar o comportamento de transdutores piezelétricos usados como transmissores (conversão de energia elétrica em mecânica), levando em conta uma configuração tipicamente empregada em aplicações de alta potência. Os transdutores foram modelados uni-dim (mais) ensionalmente considerando-se apenas modos de vibração longitudinais. Um circuito elétrico equivalente foi obtido e simulado computacionalmente. Os resultados experimentais e os calculados pelo modelo elétrico apresentaram bom ajuste. Aspectos referentes à simplificação do modelo empregado e sua viabilidade para ensino são discutidos. Resumo em inglês In this work, a method of analysis of piezoelectric transducers is shown. This method is based on the simplification of Mason’s equivalent electric circuit. An adaptation of Thévenin theorem has been employed to study the behavior of piezoelectric transducers used as transmitters (electric into mechanic energy conversion). This study was restricted to transducers with a typical configuration employed in high power applications. The transducers were one-dimensionally (mais) modeled, considering only longitudinal vibration modes. An equivalent electric circuit was obtained and computationally simulated. The experimental and calculated results show a good fitting. Features related to the simplification of the model employed and their feasibility for teaching are discussed.

Scientific Electronic Library Online (Portuguese)

4

Atenuação interaural: estudo comparativo com dois tipos de transdutores/ Interaural attenuation: comparative study with two types of transducers

Ramos, Juliana Maria Pires; Dabbur, Renata Rufino; Gil, Daniela
2009-01-01

Resumo em português OBJETIVO: Comparar os valores da atenuação interaural em um grupo de indivíduos com anacusia unilateral utilizando os fones de inserção e os supraaurais. MÉTODOS: Quinze indivíduos com anacusia unilateral foram submetidos à pesquisa do limiar de detecção de voz e à audiometria tonal liminar com os diferentes transdutores: fones TDH39 supraaurais e os fones de inserção ER-3A. Estes procedimentos foram realizados sem mascaramento contralateral. A subtração en (mais) tre o limiar da melhor orelha e o limiar não mascarado da orelha anacúsica forneceu o tamanho da atenuação interaural para as frequências de 250 a 8000 Hz e para os estímulos de fala. RESULTADOS: Em todas as frequências e para os estímulos de fala, houve diferença significativa favorecendo o ER-3A. Não houve diferença significativa entre sexo e grupo etário. CONCLUSÃO: Os fones de inserção forneceram maior atenuação interaural quando comparados aos supraaurais. Esta maior atenuação pode ser muito útil na prática da audiologia, especialmente em relação ao uso do mascaramento. Resumo em inglês PURPOSE: To compare interaural attenuation values in a group of individuals with unilateral anacusis using supra-aural earphones and insert earphones. METHODS: Fifteen subjects with complete unilateral deafness underwent pure-tone audiometry and determination of speech detection threshold with two different transducers: TDH-39 supra-aural earphones, and ER-3A insert earphone. These procedures were carried out without contralateral masking. Interaural attenuation effects f (mais) or the frequencies ranging from 250 to 8000 Hz were obtained by subtracting the unmasked threshold of the deaf ear from the threshold obtained for the normal ear. RESULTS: Interaural attenuation values were significantly greater when obtained with ER-3A earphones, for all frequencies and for speech stimuli. No differences were found between genders and age ranges. CONCLUSION: Insert earphones provided greater interaural attenuation than supra-aural earphones. This greater attenuation might be very useful for clinical audiology, especially for masking purposes.

Scientific Electronic Library Online (Portuguese)

5

Influência do tipo de transdutor na deficiência auditiva de grau profundo/ Influence of the type of transducer in profound hearing loss

Marangoni, Andréa Tortosa; Gil, Daniela
2009-09-01

Resumo em português TEMA: indivíduos com deficiência auditiva de grau profundo podem apresentar respostas por vibração com os fones supra-aurais devido a grande área do crânio exposta à vibração nestes transdutores. OBJETIVO: verificar a influência do tipo de transdutor na obtenção dos limiares auditivos por via aérea em indivíduos com deficiência auditiva neurossensorial de grau profundo. MÉTODO: 50 indivíduos, com idades variando de 16 a 55 anos, foram submetidos a anamnes (mais) e, meatoscopia, e posteriormente, a audiometria tonal liminar e limiar de detecção de voz (LDV). As audiometrias tonal e vocal foram realizadas tanto com fones supra-aurais TDH-39 quanto com os fones de inserção ER-3A. RESULTADOS: nas audiometrias tonal e vocal, notamos que, com o fone de inserção, foram obtidos limiares auditivos mais elevados do que os obtidos com o fone supra-aural, com significância estatística nas freqüências de 250Hz e 1000Hz. Ao observarmos a diferença entre os resultados obtidos com o transdutor TDH-39 e o ER-3A em cada orelha separadamente, notamos que a diferença foi maior na orelha direita com significância estatística somente na freqüência de 250 Hz. Em relação ao sexo, notamos que as diferenças entre os transdutores foram maiores no sexo masculino com significância estatística na freqüência de 250 Hz. No entanto, no LDV, a diferença maior foi encontrada no sexo feminino. CONCLUSÃO: deficientes auditivos neurossensorias de grau profundo bilateral apresentam limiares de audibilidade mais elevados (piores) com os fones de inserção do que com os fones supra-aurais nas freqüências baixas, evidenciando a existência das respostas por vibração com os fones supra-aurais. Resumo em inglês BACKGROUND: individuals with profound hearing loss may present vibrotactile responses when tested with supra-aural earphones due to the large skull area exposed to vibration in these transducers. AIM: to verify the influence of the type of transducer when assessing air conducted pure tone thresholds in individuals with profound sensorineural hearing loss. METHOD: 50 individuals, ranging in age from 16 to 55 years, were submitted to a clinical history questionnaire, meatos (mais) copy, and pure tone and speech audiometry, using both TDH-39 supra-aural earphones and ER-3A insert earphones. RESULTS: in both pure tone and speech testing, thresholds were higher when obtained using insert earphones, with statistical significant differences for 250Hz and 1000Hz. Considering right and left ear testing with the different transducers, this difference was greater for the right ear, with statistical significant differences only for 250 Hz. Regarding gender, it was observed that the difference between the transducers was greater in males, with statistical significant differences for 250 Hz. However, in the SDT (Speech Detection Threshold), the greatest difference was found in females. CONCLUSION: people with bilateral sensorineural profound hearing loss presented higher (worse) thresholds with insert earphones (ER-3A) than with supra aural earphones (TDH-39) for low frequencies (250Hz and 1000Hz), confirming the existence of vibrotactile responses with supra aural earphones.

Scientific Electronic Library Online (Portuguese)

6

Valor da ultra-sonografia abdominal com transdutor multifreqüencial de 5 a 10 mhz no diagnóstico de apendicite/ The role of abdominal ultrasonography using 5--10 MHz multifrequency transducers in the diagnosis of acute appendicitis

Costa, Jesus Irajacy Fernandes da; Coelho Filho, João Macedo; Lima, José Milton de Castro; Mota, Rosa Maria Salani; Sousa Filho, Valdecy José de
2002-03-01

Resumo em português Neste trabalho procura-se estabelecer o valor da ultra-sonografia no diagnóstico de apendicite, com transdutor multifreqüencial de 5 a 10 MHz. Foi realizado estudo transversal de casos consecutivos de 240 pacientes, de abril de 1996 a setembro de 1998, com suspeita de apendicite. Os critérios ecográficos de apendicite foram apêndice não-compressível e com espessura acima de 6,0 mm, com ou sem apendicólito e/ou coleção. O padrão ouro utilizado foram achados cir� (mais) �rgicos e acompanhamento clínico durante um ano. A prevalência de apendicite foi de 59%. A ultra-sonografia mostrou sensibilidade de 90%, especificidade de 97%, acurácia de 93%, valor preditivo positivo de 98% e valor preditivo negativo de 87%, tendo ocorrido 2,4% de falso-positivos e 13% de falso-negativos. O ultra-som com transdutor multifreqüencial de 5 a 10 MHz mostra-se um método muito eficaz no diagnóstico de apendicite. Resumo em inglês The aim of the present study was to establish the diagnostic value of abdominal ultrasonography in the diagnosis of appendicitis using 5--10 MHz multifrequency transducers. A transversal study of 240 consecutive patients examined from April 1996 to September 1998 due to suspected acute appendicitis was conducted. The ultrasonography criteria for acute appendicitis were noncompressible appendix with thickness above 6.0 mm, with or without apendicolith and/or collection. Th (mais) e adopted gold standard were surgical findings and clinical follow-up during one year. The prevalence of appendicitis was 59%. Abdominal ultrasound showed: sensitivity = 90%, specificity = 97%, accuracy = 93%, predictive positive value = 98%, predictive negative value = 87%, false positive = 2% and false negative = 13%. Ultrasonography using 5--10 MHz multifrequency transducers showed to be a very effective imaging diagnosis method for acute appendicitis.

Scientific Electronic Library Online (Portuguese)

7

Efeito das dimensões da seção transversal e da frequência do transdutor na velocidade de propagação de ondas de ultra-som na madeira/ Effect of the transversal section dimensions and transducer frequency on ultrasound wave propagation velocity in wood

Trinca, Alex Julio; Gonçalves, Raquel
2009-02-01

Resumo em português Diversas pesquisas vêm sendo realizadas com o uso da velocidade de propagação de ondas de ultra-som como parâmetro para estimar propriedades mecânicas da madeira. Tendo em vista que essa velocidade pode ser influenciada pela forma da peça ensaiada, bem como pela frequência do transdutor utilizado no ensaio, conhecer essas fontes de influência é fator importante para a obtenção de resultados confiáveis. Durante estudo mais amplo sobre a influência da dimensão (mais) do corpo-de-prova em ensaios destrutivos de compressão paralela às fibras, os corpos-de-prova de 0,03 x 0,03 x 0,09 m e de 0,05 x 0,05 x 0,15 m foram também utilizados para avaliar a variação da velocidade de propagação de ondas de ultrassom em razão da dimensão da peça ensaiada. Para a avaliação da influência da frequência, os ensaios foram realizados com transdutores de onda longitudinal (compressão) de 25 kHz, 45 kHz, 80 kHz, 100 kHz, 500 kHz e 1 MHz, em 119 corpos-de-prova de Pinus elliottii e 244 de Eucalyptus grandis. Os resultados indicaram que, em ambas as espécies, a seção transversal exerceu influência na propagação da onda de ultrassom e que a velocidade longitudinal foi fortemente afetada pela frequência do transdutor para frequências abaixo de 500 kHz, corroborando a importância de sempre se adotarem, nos ensaios, relações de comprimento de percurso/comprimento de onda superiores a 3,0. Resumo em inglês Several works use the ultrasound wave propagation velocity as the main parameter to determine the mechanical properties of wood. Since this velocity can be influenced by the specimen's dimension or by the transducer's frequency, this influence must be known to obtain reliable results. During research on the influence of specimen dimension on destructive testing of the compression parallel to the grain, 0.03 x 0.03 x 0.09 m and 0.05 x 0.05 x 0.15 m specimens were tested to (mais) evaluate the variation in wave propagation velocity as a function of specimen dimension and transducer frequency used in the tests. To evaluate transducer influence, the tests were carried out with 25 kHz, 45 kHz, 80 kHz, 100 kHz, 500 kHz and 1 MHz longitudinal transducers on 119 specimens of Pinus elliottii and 244 specimens of Eucalyptus grandis. The results show that, for both species, the transversal section dimension has an effect on ultrasound wave propagation and that longitudinal velocity was strongly affected by transducer frequency below 500 kHz, confirming the importance of adopting during the tests specimen length /wave length above 3.0.

Scientific Electronic Library Online (Portuguese)

8

Desenvolvimento de um dispositivo para medição de esforços em hastes de semeadoras de plantio direto/ Development of a device for measuring forces in shanks of no-till planters

Santo, Amauri C. E; Reis, Ângelo V. dos; Machado, Antônio L. T; Batista, Vilson J; Oldoni, André
2010-04-01

Resumo em português Inúmeros problemas relativos à mecanização dizem respeito aos esforços demandados pelas máquinas e implementos agrícolas. A medição dos esforços em implementos de hastes é geralmente feita por instrumentos complexos e de difícil construção, como os anéis octogonais. Sendo assim, o objetivo deste artigo é apresentar o desenvolvimento de um dispositivo de medição de esforços horizontais e verticais em hastes sulcadoras de semeadoras-adubadoras de plantio (mais) direto, utilizando transdutores de força extensiométricos do tipo viga em balanço, comercialmente disponíveis. Para tanto, projetou-se um dispositivo tipo pórtico, composto de dois transdutores para medição de esforços horizontais e um transdutor para medição do esforço vertical. Os três transdutores foram montados de modo a restringir qualquer movimento da haste durante a interação com o solo. O protótipo construído foi submetido a ensaios estáticos em bancada de laboratório. Em um dos ensaios, aplicou-se carga horizontal na haste; no outro, aplicou-se carga vertical e no terceiro, a carga foi aplicada com inclinação de 15º em relação à horizontal, para simular as condições de operação da haste no campo. O dispositivo mostrou-se robusto e, durante os testes de bancada, foi capaz de medir esforços horizontais de até 5.300 N, e esforços verticais de até 2.000 N, de forma linear e com grande coeficiente de correlação com as cargas aplicadas. Resumo em inglês Many problems related to the mechanization involve the draft demanded by machinery and agricultural implements. The measurement of forces in shank implements is generally made by complex and difficult building instruments, as the octagonal ring. Therefore, the aim of this paper is to present the development of a device for measuring the horizontal and vertical forces in shanks of no-till planters by employing off the shelf shear beam force transducers. For this purpose a (mais) square shaped frame was designed with two transducers for measuring horizontal forces and another transducer to measure the vertical force. They were mounted with links that restrict the movement of the shank in any direction during its interaction with the soil. A prototype was built and submitted to static laboratory bench testings. One test was made with the application of horizontal load over the shank, another with the application of vertical load and the last one with the application of load with an inclination of 15º to the horizontal to simulate the operating conditions of the shank on the field. The device proved to be robust and it was capable of measuring horizontal forces up to 5,300 N and vertical forces up to 2,000 N, in a linear fashion and with a great correlation coefficient with the applied loads.

Scientific Electronic Library Online (Portuguese)

9

Desenvolvimento de um dispositivo eletrônico para calibração de sensores de umidade do solo/ Development of eletronic device to calibrate soil moisture sensors

Leão, Raimundo A. de O.; Teixeira, Adunias dos S.; Canafístula, Francisco J. F.; Mesquita, Paulo E. G.; Coelho, Silvana de L.
2007-04-01

Resumo em português Com o advento da eletrônica e a disponibilidade de "software" de processamento, vários tipos de transdutores têm sido testados, visando à determinação da umidade do solo. O uso desses transdutores tem por objetivo a otimização do consumo de água e o conseqüente retorno econômico da atividade da agricultura irrigada. No Laboratório de Hidráulica do Departamento de Engenharia Agrícola da Universidade Federal do Ceará, construiu-se um dispositivo para calibra� (mais) �ão de sensores de umidade do solo, a sua calibração e a determinação de suas principais propriedades, como precisão e cargas mínima e máxima. O dispositivo consistiu numa torre em aço 1020, com 3,0 m de altura, no topo da qual se montou uma balança de braços. Em um dos braços da balança, colocou-se uma amostra de solo para a inserção dos sensores de umidade e, no outro, uma célula de carga para medir a variação de massa de água na amostra de solo. Foi implementado um circuito eletrônico para permitir a interface da célula de carga com um sistema de aquisição de dados. A análise de regressão, cuja variável dependente foi a saída da célula de carga, e a independente, a massa à qual a balança foi submetida, mostrou-se linear entre 1 kg e 50 kg, com coeficiente de determinação de 0,99995 e coeficiente angular de 0,09198 mV g-1. O dispositivo pode ser utilizado para calibração de sensores de umidade do solo com sensibilidade correspondente à variação de 12,28 mL de água e cargas mínima e máxima para as amostras de solo variando entre 1 e 50 kg. Resumo em inglês Several types of transducers have been tested to measure soil moisture content for irrigation purpose. Their use aims at optimizing water consumption and net profit from irrigation. A research was conducted at the Agricultural Engineering Department at the University Federal of Ceará and aimed at building a device to calibrate soil moisture sensors, in addition to find its major properties, such as accuracy, maximum and minimum loads. The device is composed of a 3-meter (mais) high iron tower, a scale, load cell and a data acquisition system. In one the arms of the scale a horizontal soil column was mounted and adapted to receive soil moisture sensors. In the other arm a load cell was installed in order to measure the change in water content of the soil. A electronic circuit was constructed to allow for the interfacing of the load cell with a data acquisition system. The response of the scale in volts to a load (in grams) shows to be linear between 1 kg and 50 kg, with a correlation coefficient of 0.99995 and slope of 0.09198 mV g-1. The combination to the data acquisition system used resulted in a sensitivity of 12.28 mL of water per count, and minimum and maximum loads of 1 kg and 50 kg, respectively.

Scientific Electronic Library Online (Portuguese)

10

O uso do ultra-som (US) na reumatologia/ Ultrasound (US) use in rheumatology

Azevedo, Ana Beatriz Cordeiro de; Martins, Emiliano Pontes; Holanda, Haroldo Tenório de; Mitraud, Sônia de Aguiar Vilela; Fernandes, Artur da Rocha Correa; Ciconelli, Rozana Mesquita
2005-12-01

Resumo em português Nos últimos anos, a ultra-sonografia tem consolidado o seu papel como importante meio de diagnóstico por imagem na avaliação de doenças com comprometimento do sistema musculoesquelético. O desenvolvimento de novas tecnologias aplicadas na utilização do ultra-som (US), como novos transdutores, softwares e o Doppler, tornou possível a visualização de estruturas intra-articulares e da vascularização sinovial. Atualmente, além de auxiliar no diagnóstico de les� (mais) �es de partes moles e identificação de coleções líquidas, o ultra-som tem sido empregado na avaliação de estruturas articulares comprometidas por doenças reumáticas e como guia para a realização de procedimentos em reumatologia. Resumo em inglês In the past years, ultrasonographic studies achieved a solid position as an important method of imaging diagnosis in the evaluation of musculoskeletal diseases. Visualization of intra-articular structures and synovial vascular flow improved with the development of new ultrasound technologies, as better transducers, software and Doppler techniques. Ultrasound is being applied as an assistant diagnostic tool in the identification of soft tissue lesions and fluid collections (mais) , evaluation of articular structures compromised by rheumatic diseases and also as a guidance tool for invasive procedures in rheumatology, like joint aspiration and injection.

Scientific Electronic Library Online (Portuguese)

11

Efeito do comprimento do corpo-de-prova na velocidade ultra-sônica em madeiras/ Effect of the size of the specimen on ultrasonic velocity

Oliveira, Fabiana Goia Rosa de; Miller, Karla Peitl; Candian, Marcela; Sales, Almir
2006-02-01

Resumo em português O presente artigo apresenta um estudo sobre a variação da velocidade ultra-sônica longitudinal em função do comprimento da peça de madeira. As espécies utilizadas foram: pinus caribaea (Pinus caribaea var. caribaea) eucalipto citriodora (Eucalyptus citriodora), eucalipto grandis (Eucalyptus grandis) e jatobá (Hymenaea sp). Utilizou-se equipamento de ultra-som com transdutores exponenciais de 22 kHz. Foram feitas medições do tempo de propagação das ondas ultra- (mais) sônicas, com o comprimento variando de 300 cm a 10 cm e mantendo-se a seção transversal constante de 12 cm x 5 cm. Os resultados apontaram que ocorre variação da velocidade em função da distância percorrida e do comprimento de onda (lambda) utilizado. Conclui-se que adequar a freqüência do transdutor com o comprimento da peça é essencial para a determinação correta da velocidade ultra-sônica em madeiras. Resumo em inglês This paper reports on a study of the variation of ultrasonic velocity with the length of the specimen of pinus caribaea (Pinus caribaea var. caribaea) eucalipto citriodora (Eucalyptus citriodora), eucalipto grandis (Eucalyptus grandis) and jatobá (Hymenaea sp). Ultrasonic measurements were taken with an experimental apparatus having 22 kHz transducers. Tests were carried out with length from 300 cm to 10 cm and constant cross-section (12 cm x 5 cm). The results showed th (mais) at velocity of ultrasonic waves is sensitive to changes in the distance between transducers and wavelength (lambda). The adjustment between the frequency of transducer and the length of the specimen is essential in order to obtain correct measurements of ultrasonic velocity in wood.

Scientific Electronic Library Online (Portuguese)

12

Simulação computacional de campos ultra-sônicos/ Computational simulation of ultrasonic fields

Arnold, Francisco J.; Pelá, Carlos A.
2004-01-01

Resumo em português Quando um transdutor eletro-acústico é excitado eletricamente, ele produz no meio de propagação onde está inserido um campo acústico. Através do conhecimento dos campos acústicos pode-se colher importantes subsídios para projetos de transdutores e estudos da interação com os meios de propagação. Neste trabalho é apresentada uma proposta de atividade interdisciplinar envolvendo conteúdos de Física, Matemática e Computação ministrados nas disciplinas intr (mais) odutórias dos cursos superiores de ciências exatas e tecnológicas. O trabalho propõe a discussão dos fenômenos de interferência ondulatória, o cálculo do campo acústico usando coordenadas cilíndricas e a programação do método matemático através de instruções básicas de uma linguagem de programação. As simulações de alguns campos acústicos são apresentadas na forma de gráficos bi e tridimensionais e os resultados são discutidos. Resumo em inglês When an electro-acoustical transducer is electrically supplied, it yields an acoustic field in the propagation medium. The acoustic field knowledge allows us to obtain significant help to transducers design and propagation medium interaction studies. In this paper, it is shown a proposal of classroom work involving the studied contents of physics, mathematic and computing in the introductory lessons of degree course of exact science. It is proposed the discussion about wa (mais) ve interference phenomena, the determination of acoustic field using cylindrical coordinates and the software of the mathematical method applying basic instructions of a computational language. The simulations of some acoustic fields are shown in bi and tri-dimensional graphics and the results are discussed.

Scientific Electronic Library Online (Portuguese)

13

Biomicroscopia ultra-sônica em esclerectomia profunda: relato de caso/ Ultrasound biomicroscopy in deep sclerectomy: case report

Villas-Bôas, Flávia; Allemann, Norma; Morales, Maira Saad Avila; Omi, Carlos Akira
2008-06-01

Resumo em português Relato do caso de um paciente com diagnóstico de glaucoma primário de ângulo aberto, que foi submetida a esclerectomia profunda em olho direito, com sucesso. No pós-operatório de 3 meses, o procedimento cirúrgico foi avaliado com biomicroscopia ultra-sônica (UBM) utilizando-se dois equipamentos distintos (UBM 840-Zeiss; UBM-VUMAX-Sonomed) com transdutores de 50 MHz. O método diagnóstico com biomicroscopia ultra-sônica pode ser usado como método não invasivo pa (mais) ra avaliar a arquitetura interna ocular na topografia da esclerectomia profunda. Permite identificar as estruturas do segmento anterior, sua relação anatômica, bem como a membrana trabéculo-Descemet íntegra e o espaço intra-escleral. Biomicroscopia ultra-sônica demonstrou utilidade na avaliação pós-operatória do procedimento cirúrgico. Resumo em inglês Case report of a woman with the diagnosis of primary open-angle glaucoma who was submitted to a successful surgical procedure of deep sclerectomy in the right eye. In the postoperative period, at month 3, the surgical procedure was evaluated with ultrasound biomicroscopy (UBM) utilizing two distinct equipments (UBM 840-Zeiss; UBM-VUMAX-Sonomed), with 50-MHz transducers. The diagnostic method of ultrasound biomicroscopy can be utilized as a non invasive method to evaluate (mais) the internal architecture of the eye at the topography of deep sclerectomy. It allows to identify the anterior segment structures, their anatomical relationship, and also the intact trabecular-Descemet membrane and the intrascleral space. Ultrasound biomicroscopy showed to be useful in evaluating postoperative status of the surgical procedure.

Scientific Electronic Library Online (Portuguese)

14

Ultra-sonografia tridimensional em ginecologia: malformações uterinas/ Three-dimensional ultrasound in gynecology: uterine malformations

Ferreira, Adilson Cunha; Mauad Filho, Francisco; Nicolau, Luis Guilherme; Gallarreta, Francisco M. Pancich; Paula, Wellington Martins de; Gomes, Débora Cristina
2007-04-01

Resumo em português As malformações uterinas são achados pouco comuns na clínica ginecológica. As estatísticas nesta área são muito falhas. Corrobora, ainda, a falta de uniformização na terminologia empregada e as dificuldades diagnósticas. A partir da década de oitenta, a ultra-sonografia tornou-se um procedimento indispensável à prática toco-ginecológica, contribuindo e modificando conceitos e procedimentos dentro dessa especialidade. O advento dos transdutores endocavitár (mais) ios, a análise com Doppler colorido de amplitude e espectral, assim como a melhoria crescente da qualidade de imagem contribuíram para isso. Nos últimos dez anos muito se tem pesquisado, publicado e discutido sobre o papel da ultra-sonografia tridimensional. Os autores fazem uma revisão do tema e ressaltam a importância dessa metodologia como modalidade diagnóstica. Resumo em inglês Uterine malformations are unusual findings in the clinical practice of gynecology. Statistics regarding this abnormality are flawed, and there is a lack of standardization of the pertinent terminology, besides difficulty in the diagnosis. Starting in the 1980's, ultrasound became a procedure indispensable to the clinical practice in the field of tocogynecology, modifying concepts and procedures, and bringing an important contribution to this specialty. The advent of endoc (mais) avitary transducers, amplitude and spectral color Doppler, as well as the increasing improvement in the imaging quality, has contributed to this progress. Over the last ten years, much has been studied, published and discussed about the role of the three-dimensional ultrasonography. The authors review the topic and emphasize the importance of this method as a diagnostic modality.

Scientific Electronic Library Online (Portuguese)

15

O uso da ultra-sonografia no diagnóstico e evolução da apendicite aguda/ Ultrasonography in the diagnosis and evolution of acute appendicitis

Zorzetto, Arquimedes Artur; Urban, Linei Augusta Brolini Dellê; Liu, Christian Bark; Cruz, Olívia Russo; Vitola, Maria Luiza Malfi; Awamura, Yumi; Nascimento, Alessandra Bettega
2003-03-01

Resumo em português OBJETIVO: Aproximadamente 35% das apendicites agudas têm diagnóstico clínico pré-operatório duvidoso ou incorreto, particularmente grávidas e crianças. A ultra-sonografia, em virtude do seu baixo custo e facilidade de acesso, tem-se mostrado um método diagnóstico importante. Este estudo propôs-se a demonstrar os principais achados de imagem das diversas fases da apendicite, com o objetivo de auxiliar o ultra-sonografista no diagnóstico precoce desta afecção. (mais) MATERIAIS E MÉTODOS: São relatados 14 casos de ultra-sonografias abdominais realizadas no período de janeiro a julho de 2001, em pacientes que se apresentavam com quadro de abdome agudo. O exame foi realizado com transdutores de 3,5 MHz e 7,5 MHz. RESULTADOS: O estudo ultra-sonográfico antes da perfuração demonstra apêndice não compressível, com espessamento e perda focal da definição das paredes. Após a perfuração, o apêndice pode não ser visualizado ao exame de ultra-sonografia, sendo evidenciadas alterações secundárias como efeito de massa, formação de plastrão, liquefação e formação de abscesso, além de ar dentro da coleção. CONCLUSÃO: O diagnóstico precoce da apendicite é essencial para minimizar a morbidade, que se mantém elevada se ocorrer perfuração. Apresentações atípicas resultam em confusão diagnóstica e retarde no tratamento. As principais dificuldades e erros são apendicite retrocecal, apendicite focal ou perfurada. Resumo em inglês OBJECTIVE: Approximately 35% of the patients with acute appendicitis have a doubtful or incorrect preoperatory diagnosis, particularly in pregnant women and children. Ultrasonography has demonstrated to be an important means of diagnosis due to its low cost and easy access. This study is intended to show the main imaging findings of the many phases of appendicitis, thus helping the ultrasonographist to establish an early diagnosis. MATERIALS AND METHODS: From January to J (mais) une 2001, 14 patients with acute abdominal pain were submitted to abdominal ultrasound using 3.5 MHz and 7.5 MHz transducers. RESULTS: The ultrasound findings when perforation had not occurred demonstrated a noncompressible appendix, thickening and focal lack of definition of the walls. After perforation had occurred the appendix could no longer be visualized at ultrasonography. Secondary changes such as mass effect, phlegmous changes, liquefaction and abscess formation, and gas bubbles within a collection were identified. CONCLUSION: An early diagnosis of appendicitis is essential in order to minimize morbidity that is high when perforation occurs. Atypical presentations result in misdiagnosis and treatment delay. The main diagnostic challenges are retrocecal, focal or perforated appendicitis.

Scientific Electronic Library Online (Portuguese)

16

Obtenção de substratos cerâmicos no sistema Si-Al-O-N-C empregando polissiloxanos e carga de Si e Al2O3/ Ceramic tapes of Si-Al-O-N-C compounds using mixtures of polyssiloxane and Si-Al2O3 fillers

Rocha, R. M.; Scheffler, M.; Greil, P.; Bressiani, J. C.; Bressiani, A. H. A.
2005-03-01

Resumo em português A técnica de processamento de colagem por fita (tape casting) tem sido amplamente utilizada na obtenção de cerâmicas para diferentes aplicações: substratos cerâmicos e estruturas planares em multicamadas para circuitos integrados e capacitores; eletrólitos sólidos para células a combustível e sensores; cerâmicas piezoelétricas para atuadores e transdutores; membranas de separação para micro-filtragem; compósitos estruturais e trocadores de calor. Neste tra (mais) balho, a técnica convencional de colagem por fita foi adaptada com a utilização do processo de pirólise controlada de misturas de polímeros e carga, empregando-se polissiloxanos e cargas de silício e alumina nas suspensões. Foram preparadas suspensões com 60% vol. de fase polimérica (polissiloxanos e metil-trietoxi-silano) e 40% vol. de carga (Si e Al2O3), com diferentes concentrações dos polímeros e das cargas. As amostras na forma de substratos foram pirolisadas em atmosfera de nitrogênio a 1400 °C/2 h e 1500 °C/2 h, sendo convertidas em materiais cerâmicos no sistema Si-Al-O-N-C. O processo de pirólise foi caracterizado até a temperatura de 1000 ºC por análise termogravimétrica. As cerâmicas foram caracterizadas quanto às fases formadas, microestrutura, massa específica aparente e condutividade térmica. Os substratos cerâmicos apresentaram porosidade relativamente alta (entre 12 e 22%) e baixa condutividade térmica (entre 3 e 8 W/m.K), sendo constituídos por fases cristalinas de beta-SiC, Si2ON2, O'-SiAlON, Al2O3, mulita e fase amorfa de SiOC; o Si foi observado nas amostras pirolisadas a 1400 ºC. Resumo em inglês The tape casting technique has been widely used to prepare ceramic tapes for different applications: ceramic substrates and multilayer planar structures for integrated circuits and capacitors, solid electrolytes for fuel cells and sensors, piezoelectric ceramics for actuators and transducers, membrane systems for micro-filtration, structural composites and heat exchanger. In this work the conventional tape casting technique was adapted to utilize the active filler control (mais) led polymer pyrolysis process making use of polyssiloxanes and fillers in the initial suspension. Suspensions were prepared with 60 vol. % of polymeric phase (polyssiloxanes and methyl-trietoxy-silane) and 40 vol. % of fillers (Si and Al2O3) with different contents of polymer and fillers. The cured tapes were pyrolysed In nitrogen atmosphere at 1400 ºC/2 h and 1500 ºC/2 h, converting the material to ceramic tapes in the Si-Al-O-N-C system. The pyrolysis process was characterized by thermogravimetry up to 1000 ºC and pyrolyzed tapes were characterized according to phase formation, microstructure, density and thermal conductivity. The converted tapes showed relatively high porosity (between 12 and 22%) and low thermal conductivity (between 3 and 8 W/m.K.). The tapes are mainly composed by crystalline phases of beta-SiC, Si2ON2, O'SiAlON, Al2O3 and mullite and a SiOC amorphous phase; Si was observed in tapes pyrolysed at 1400 ºC.

Scientific Electronic Library Online (Portuguese)

17

Avaliação estatística da variação da velocidade de propagação de ondas de ultra-som na madeira em presença de defeitos/ Statistical evaluation of the ultrasonic wave velocity variation in defective wood

Puccini, Carlos T.; Gonçalves, Raquel; Monteiro, Mariu E. A.
2002-12-01

Resumo em português Os métodos visuais para a detecção de defeitos na madeira, ainda que de grande utilidade, podem ser falhos e exigem a utilização de mão-de-obra relativamente bem treinada. Muitas vezes, a presença de nós, rachaduras ou, ainda, regiões com medula no interior de uma peça serrada, podem ser imperceptíveis na avaliação visual. Um dos grandes avanços obtidos nos últimos anos na caracterização de materiais, tanto do ponto de vista mecânico quanto da qualidade, (mais) é a aplicação de técnicas que utilizam a propagação de ondas, destacando-se, dentre elas, o ultra-som. O objetivo deste trabalho é avaliar, estatisticamente, a possibilidade de se utilizar o método do ultra-som na detecção de defeitos em peças de madeira serrada. Para isto, foram utilizadas 180 peças de dimensões nominais: 0,027 m de espessura; 0,10 m de largura e 0,25 m de comprimento, retiradas de vigas de Pinus sp obtidas em serraria da cidade de Campinas. As peças foram ensaiadas na umidade de equilíbrio ao ar. Para a realização dos ensaios utilizou-se o equipamento de emissão de ondas de ultra-som marca Steinkamp BP-7 com transdutores de 45 kHz. Inicialmente foi realizada uma análise visual das peças e, posteriormente, a determinação da velocidade de propagação das ondas nas mesmas peças. Com os resultados, realizou-se uma análise exploratória das variáveis e obteve-se um modelo de regressão logística visando verificar a relação entre a presença ou não de defeitos e a velocidade de propagação da onda do ultra-som na madeira. Os resultados demonstram uma forte relação entre a velocidade de propagação da onda de ultra-som e os defeitos detectados pela análise visual Resumo em inglês Visual methods to detect wood defects, although of great utility, can lead to inaccurate results and demand a specialist to carry it out. The presence of knots, cracks or pith regions inside a sawed piece can be imperceptible in the visual evaluation. One of the greatest progress obtained in the last years in the characterization of materials - not only to determine its mechanical properties but also its quality - is the application of acoustic techniques like the ultraso (mais) und. The objective of this study is to evaluate, by statistical analysis, the sensibility of the ultrasonic method for detection of defects in pieces of sawed wood. For the trail, 180 pieces of Pinus sp. with 0.027 m of thickness, 0.10 m of width and 0.25 of length were used. These pieces tested under air dried condition (approximately 12% moisture content), were obtained at a saw mill in Campinas. The velocity of ultrasonic waves was measured by Steinkamp BP-7 ultrasound equipment with 45 kHz transducers. Initially the pieces were analyzed by visual method and later the velocity of ultrasonic waves through the wood pieces was measured. An exploratory analysis of the variables was done and a logistic regression model was obtained. The objective was to verify the relationship for the presence or absence of defects in the wood and the velocity of ultrasonic wave propagation. The results demonstrate a strong relationship between the ultrasonic wave propagation and the defects detected by the visual analysis

Scientific Electronic Library Online (Portuguese)

18

Manometria esofágica: limpeza e desinfecção do equipamento com glutaraldeído. Protocolo do Hospital de Clínicas de Porto Alegre, RS/ Esophageal manometry: equipment cleaning and disinfection with glutaraldehyde

MÜLLER, Suzana; GRUBER, Antônio Carlos; HOEFEL, Heloísa H. K.; BARROS, Sérgio Gabriel Silva de
2001-10-01

Resumo em português Racional - A necessidade de desinfecção e esterilização apropriada de materiais reutilizáveis, com a finalidade de evitar infecções cruzadas, tem sido enfatizada por inúmeras publicações. Assim como os endoscópios, os cateteres de manometria esofágica são considerados materiais semicríticos e devem estar livres de microorganismos. Objetivo - Padronizar o processo de limpeza e desinfecção do material e equipamento de manometria esofágica no Serviço de Man (mais) ometria do Hospital de Clínicas de Porto Alegre, RS, a fim de garantir a segurança dos pacientes na reutilização de materiais semicríticos, baseado em protocolos internacionais e de acordo com a Comissão de Controle de Infecção Hospitalar do Hospital de Clínicas de Porto Alegre. Material e Métodos - Foi utilizado detergente enzimático para a limpeza do cateter, seguido de imersão em glutaraldeído a 2% por 20 minutos para desinfecção de alto nível. O reservatório foi armazenado limpo e seco. Foram consultados os protocolos utilizados pelo Hôpital Edouard Herriot, Lyon, França e pela Sociedade Americana de Enfermeiras do Trato Gastrointestinal e Associados. Conclusões - A desinfecção de alto nível com glutaraldeído a 2%, precedido de limpeza com detergente enzimático, constitui técnica segura e simples para evitar transmissão de infecções cruzadas no material e equipamento de manometria esofágica, devendo ser realizada após cada procedimento. Os transdutores, pelas suas características, devem ser reesterilizados em óxido de etileno a cada 6 meses. Os profissionais envolvidos nesta área devem trabalhar conjuntamente com a Comissão de Controle de Infecção Hospitalar, conhecer normas e portarias do País e manterem-se atualizados quanto a novos processos de esterilização de materiais oferecidos no mercado. Resumo em inglês Background - Many publications have emphasized the need of proper cleaning, disinfection and sterilization process for reused materials intended to prevent cross infections. As the endoscope the esophageal manometry catheters are considered as semicritical materials and must be free of microrganisms. Aim - To standardize the esophageal manometry materials cleaning and disinfection process to guarantee the safety of patients when reusing semicritical materials. It was base (mais) d on international protocols and according to recommendations of the Hospital Infection Control Commission of the "Hospital de Clínicas de Porto Alegre", Porto Alegre, RS, Brazil. Materials and Methods - Enzymatic detergent was used for catheter cleaning, followed by immersion with 2% glutaraldehyde solution during 20 minutes for high-level disinfection. The water reservatory was kept clean and dry to prevent microorganisms proliferation. Conclusions: The high level disinfection with 2% glutaraldehyde, preceded by enzymatic detergent cleaning, is a safe and simple technique that avoids cross infection in the esophageal manometry equipment. This care must be taken after each manometric procedure. The transducers must be resterilized in ethylene oxide. The professionals of this area must work in concordance with the Hospital Infection Control Commission, being acquainted with the country laws and regulations and keeping sterilizing process and materials updated.

Scientific Electronic Library Online (Portuguese)

19

Relação entre comprimento craniocaudal e diâmetro da vesícula embrionária/fetal com idade de gestação por meio de avaliação ultra-sonográfica em ovino da raça Bergamácia/ Relationship between crown-rump length and embryonic/fetal vesicle diameter with gestational age in ovine of Bergamácia breed by ultrasonography

Chalhoub, M.; Prestes, N.C.; Lopes, M.D.; Ribeiro Filho, A.L.; Lopes, R.M.; Trinca, L.A.
2001-02-01

Resumo em português Este trabalho objetivou relacionar o diâmetro da vesícula embrionária/fetal (DVE) e comprimento craniocaudal do embrião/feto (CCC) do 15º ao 45º dia de gestação com a idade de gestação em ovelhas. Utilizaram-se 19 ovelhas adultas da raça Bergamácia, com cio sincronizado e cobertas por um mesmo reprodutor. A avaliação ultra-sonográfica foi realizada diariamente do 15º ao 30º dia após a cobrição e a cada cinco dias do 30º ao 45º dia, utilizando-se apar (mais) elho com transdutor linear de 5,0 e 7,5MHZ. O crescimento diário médio do DVE e CCC foi de 1,40mm e 1,33mm, respectivamente. A calibragem inversa obtida para DVE foi: Dias = -11 + 50(0,1 + 0,04log DVE)½, com R² = 0,85 e para CCC foi: Dias = 13,63 + 12,5(-0,71 + 0,16CCC)½, com R² = 0,93. Tanto o DVE como o CCC obtidos por ultra-sonografia são medidas pelas quais se pode prever a idade de gestação em ovelhas da raça Bergamácia. Resumo em inglês This study aimed to relate embryonic/fetal vesicle diameter (EVD) and crown-rump length (CRL) to gestational age in ewes from the 15th to the 45th day of pregnancy. Nineteen adult Bergamácia ewes with synchronized estrus were mated by the same male. Ultrasonographic evaluations were performed every 24 hours from the 15th to the 30th day after mating and every five days from the 30th to the 45th day using 5.0 and 7.5MHZ linear transducers. Average daily growth of EVD and (mais) CRL were 1.40mm and 1.33mm, respectively. The inverse calibration obtained for EVD was: Days = -11 + 50(0.1 + 0.04log EVD)½ with R² = 0.85, and for CRL was: Days = 13.63 + 12.5(- 0.71 + 0.16CRL)½ with R² = 0.93. Both EVD and CRL obtained by ultrasonography are useful measurements that allow the prediction of gestational age in Bergamácia ewes.

Scientific Electronic Library Online (Portuguese)

20

Estimulação elétrica neuromuscular e estimulação eletrotáctil na restauração artificial da preensão e da propriocepção em tetraplégicos/ Neuromuscular electrical stimulation and electron-tactile stimulation in rehabilitation of artificial prehension and proprioception in tetraplegic patients

Castro, Maria Claudia Ferrari de; Cliquet Jr., Alberto
2001-09-01

Resumo em português Esse trabalho discute o uso da estimulação elétrica na reabilitação sensoriomotora de membros superiores paralisados. A restauração da função motora de preensão foi obtida pela aplicação da estimulação elétrica neuromuscular, em seqüências de ativação adequadas a realização de atividades do cotidiano como comer, beber, escrever e digitar. Uma luva instrumentalizada com sensores de força possibilitou quantificar o padrão de movimento exercido artific (mais) ialmente. Esse sistema foi utilizado como alça de realimentação para a restauração de uma propriocepção através da aplicação da estimulação eletrotáctil, possibilitando a evocação de sensações tácteis codificadas, relacionadas ao movimento artificial. A integração sensoriomotora se deu pela aplicação simultânea dos sistemas desenvolvidos, possibilitando desde a restauração de padrões funcionais de preensão, até o reconhecimento do padrão de movimento exercido através das sensações evocadas artificialmente. Resumo em inglês This paper discusses the use of electrical stimulation in upper limb sensorial and motor rehabilitation. Neuromuscular electrical stimulation (NMES) was used aiming to restore motor hand function by means of muscle activation sequences to perform daily living activities such as drinking, eating, writing and typewriting. Custom made gloves instrumented with force transducers were used aiming quantitative evaluation of the artificially generated movement. This system was us (mais) ed as a sensorial feedback supplier for an artificial proprioception system. Encoded tactile sensation relating to artificially generated movements was provided by electron-tactile stimulation. The results showed that the sensorial-motor integration attained yielded both functional movement restoration and the recognition of artificial grasp force patterns, in order to allow the neuroprosthetic system to become closer to the biologic system.

Scientific Electronic Library Online (Portuguese)

21

Biossensores baseados no processo de inibição enzimática/ Biosensors based on the enzymatic inhibition process

Marques, Paulo Roberto Brasil de Oliveira; Yamanaka, Hideko
2008-01-01

Resumo em inglês Fast, selective, reproducible and reliable detections have been carried out by using enzymatic biosensors in several areas. The enzymatic biosensors based on the inhibition represent an important role in analytical chemistry. Enzymes like cholinesterases, peroxidases, tyrosinases, etc. have been immobilized on electrochemical and optical transducers and the enzymatic activity decreasing in the presence of the inhibitor is related with its concentrations. This article pres (mais) ents a review on the enzymes used on the construction of these sensors, emphasizing the respective applications.

Scientific Electronic Library Online (Portuguese)