Sample records for titanium
from WorldWideScience.org

Sample records 1 - 20 shown. Select sample records:



1

Filmes de titânio-silício preparados por "spin" e "dip-coating"/ Titanium-silicon films prepared by spin and dip-coating

Nassar, Eduardo J.; Ciuffi, Katia J.; Gonçalves, Rogéria R.; Messaddeq, Younes; Ribeiro, Sidney J. L.
2003-10-01

Resumo em inglês The conditions for the preparation of luminescent materials, consisting of Eu3+ ions entrapped in a titanium matrix, in the forma of a thin film, using the sol-gel process, are described. The films were obtained from sols prepared with TEOS and TEOT, in the presence of acetylacetone as the hidrolysis-retarding agent, using the dip-coating and spin-coating techniques. The influence of these techniques on the films based on titanium and silicon are presented. The Eu3+ was u (mais) sed as a luminescent probe. The films have been characterized by luminescence, reflection and transmittance. The thickness of the films could be related to the preparation procedure. Transparent thin films have been prepared by dip-coating technique.

Scientific Electronic Library Online (Portuguese)

2

Dióxido de titânio sol-gel: propriedades e comportamento eletrocrômico/ Sol-gel titanium dioxide: properties and electrochromic behavior

Zoppi, Rita Aparecida; Mortean, Nelson Henrique Ribeiro
2000-12-01

Resumo em inglês Titanium dioxide was prepared by hydrolysis and polycondensation of titanium tetraisopropoxide. TiO2 films were obtained by spin coating of the precursor solution on ITO substractes (glass covered with indium doped tin oxide). Films were prepared using different temperatures and hydrochloric acid contents. The effect of the drying temperature of the films (100 or 400ºC) was also investigated. TiO2 films were characterized by cyclic voltammetry, chronoamperometry, ultraviolete-visible spectroscopy, scanning electron microscopy and X-ray diffractrometry.

Scientific Electronic Library Online (Portuguese)

3

Obtenção de titânio metálico com porosidade controlada por metalurgia do pó/ Porous titanium production and porosity control by powder metallurgy (P/M)

Braga, Neila de Almeida; Ferreira, Neidenêi Gomes; Cairo, Carlos Alberto Alves
2007-04-01

Resumo em inglês Titanium is an attractive material for structural and biomedical applications because of its excellent corrosion resistance, biocompatibility and high strength-to-weight ratio. The high reactivity of titanium in the liquid phase makes it difficult to produce it by fusion. Powder metallurgy has been shown to be an adequate technique to obtain titanium samples at low temperatures and solid-phase consolidation. The production of compacts with different porosities obtained by (mais) uniaxial pressing and vacuum sintering is briefly reviewed. Powder particle size control has been shown to be very important for porosity control. Sample characterization was made using scanning electron microscopy (SEM) images.

Scientific Electronic Library Online (Portuguese)

4

Miniplacas de titânio na redução de fraturas mandibulares em cães e gatos: estudo de seis casos/ Titanium miniplates in mandibular fracture repair in dogs and cats: study of 6 cases

Gomes, Cristiano; Gouvêa, Aline Silva; Alievi, Marcelo Meller; Contesini, Emerson Antonio; Pippi, Ney Luis
2010-05-01

Resumo em português Fraturas de mandíbula e maxila são comuns em cães e gatos, correspondendo a cerca de 3 a 6% de todas as fraturas. Muitos tratamentos são propostos para a correção desse defeito, como o uso de pino intramedular, a fixação esquelética externa, a cerclagem e o uso de acrílicos e placas ósseas. Este estudo teve como objetivo avaliar o uso das mini e microplacas de titânio do sistema 2,0 e 1,5mm no tratamento de fraturas mandibulares, em cães e gatos, respectivame (mais) nte. Os parafusos e as miniplacas utilizadas são compostos de titânio, e o formato dependeu da localização e do tipo de fratura. No total, foram avaliados seis casos, dos quais quatro apresentaram completa consolidação, sendo as placas utilizadas como método único ou associado com fio de aço ou imobilização com focinheira. As causas de insucesso foram a quebra da placa em um dos casos e a contaminação do enxerto, com posterior osteomielite em decorrência da deiscência dos pontos em outro caso. O emprego das miniplacas de titânio mostrou-se eficaz na maioria dos casos testados, promovendo fixação rígida e retorno funcional adequado, sendo utilizado como método único ou associado com outras técnicas de osteossíntese. Resumo em inglês Jaw and maxilla fractures are common in dogs and cats, representing 3-6% of all fractures. Numerous techniques are proposed to reduce the defect such as intramedullary pin, percutaneous skeletal fixation, circumferential wiring, acrylic splints and bone plating. This study aimed to evaluate the use of 2.0mm and 1.5mm titanium microplates in the treatment of mandibular fractures in dogs and cats, respectively. The screws and the mini and microplates used were composed of t (mais) itanium and their format depended on the location and type of fracture. A total of 6 cases were selected and 4 of them had complete consolidation using the mini microplate method alone or associated with steel wire or tie with noseband. In one case the failure occurred due to plate breakage and other implant failed due to dehiscence of the skin suture. The use of mini titanium microplates was effective in most cases, as a single method or combined with other techniques of osteosynthesis, because it promoted rigid fixation and return to the appropriate function.

Scientific Electronic Library Online (Portuguese)

5

Microplacas de titânio em fraturas de tibiotarso em pombos domésticos/ Titanium microplates for treatment of tibiotarsus fractures in pigeons

Gouvêa, Aline Silva; Alievi, Marcelo Meller; Noriega, Verônica; Dal-Bó, Ísis dos Santos; Pinto, Thadeu Mourão; Menezes, Cláudio Leonardo Montassieur de; Silva, Renato Barbosa; Silva, Luciana Machado da; Velasque, Andréa Gonçalves; Pinto, Luciana Andreatta Torelly; Coelho, Ana Júlia Andrade
2011-03-01

Resumo em português Entre os problemas cirúrgicos das aves, as fraturas são os de maior prevalência. Em virtude das variações no tamanho, peso, anatomia óssea peculiar, alta incidência de fraturas complicadas e das diferentes demandas funcionais entre espécies e indivíduos, não foi possível estabelecer ainda um método ideal de osteossíntese para os ossos longos das aves. Microplacas de titânio comumente utilizadas em cirurgias maxilofaciais de humanos foram empregadas recenteme (mais) nte na osteossíntese de aves, porém com poucos resultados disponíveis. O objetivo do presente estudo foi avaliar a utilização das microplacas de titânio no tratamento de fraturas experimentais de tibiotarso em pombos domésticos (Columba livia). Foram utilizadas 30 aves adultas, machos e fêmeas, com 7 meses de idade, pesando entre 400 a 500 gramas. Os animais foram separados em três grupos de dez, sendo que no grupo 1 foi utilizado uma microplaca de titânio com 6 furos e espaçador central; no grupo 2, com oito furos sem espaçador central; e, no grupo 3, com oito furos com espaçador central. Após avaliação clínica, as aves foram submetidas à osteotomia médio-diafisária no tibiotarso direito para colocação das diferentes configurações de microplaca de titânio, sendo fixadas com microparafusos de titânio com 7mm de comprimento. Os animais foram avaliados clínica e radiograficamente até os 90 dias de pós-operatório. Após esse período, foi realizada eutanásia em duas aves de cada grupo. Em todas elas, foi observada a consolidação óssea, sendo que, no grupo 1, o tempo médio e o desvio padrão foram 32,9±9,9; no grupo 2, 30,8±6,7 e, no grupo 3, 26,6±6,4 dias, não havendo diferença estatística entre os grupos. O envergamento do implante foi a complicação mais frequente. A configuração da microplaca resultou em diferença estatisticamente significativa em relação à deambulação e ao grau de envergamento nos diferentes grupos, sendo que, no grupo 3, houve maior precocidade no apoio do membro e menor grau de envergamento em relação aos outros grupos. Histologicamente, foi verificada a formação de calo ósseo em todos os animais e presença de tecido ósseo ao redor da microplaca e dos microparafusos. Apesar das complicações observadas, as microplacas de titânio são uma opção para osteossíntese de tibiotarso em aves de médio porte. Resumo em inglês Among the surgical problems in birds, the fractures are the most prevalent. Due to variations in size, weight, peculiar bone anatomy, high incidence of complicated fractures and functional demands of different species and individuals, it is still not possible to establish an ideal method for osteosynthesis of long bones in birds. Titanium microplates commonly used in human maxillofacial surgery have been recently employed in osteosynthesis of birds, but with few results a (mais) vailable. The aim of this study was to evaluate the use of titanium microplates in the treatment of tibiotarsus fractures in 30 pigeons (Columba livia) , adult males and females, with 7 months old, weighing from 400 to 500. The animals were divided into 3 groups with ten animals each. In group 1, a titanium microplate with 6 holes and a central spacer was used; in group 2, a titanium microplate with 8 holes without a spacer in the center was used; in group 3, a titanium microplate with 8 holes with central spacer was used. After clinical evaluation, the birds were submitted to mid-diaphyseal osteotomy in the right bone for placement of different configurations of the titanium plate, and fixed with titanium microscrews 7mm long. The animals were evaluated clinically and radiographically until 90 days postoperatively. After this period, euthanasia was performed in 2 animals from each group. In all animals was observed bone healing and in group 1 the mean and standard deviation were 32.9±9.9 days, in group 2, 30.8±6.7 days in group 3, 26.6±6.4 days. There was no statistical difference in healing time between groups. The bending of the implant was the most common complication. The configuration of the plate resulted in a statistically significant difference in relation to walking and to the degree of bending in the different groups. Moreover, in group 3 there was higher precocity in the member suppor and a lower degree of bending in relation to other groups. Histologically, it was verified formation of the callus in all animals and presence of bone tissue around the plate and microscrews. Despite the complications of titanium microplates, they are an option for tibiotarsus osteosynthesis in birds of medium size.

Scientific Electronic Library Online (Portuguese)

6

Uso da prótese vertical expansível de titânio para costela no tratamento da cifose congênita em portadores de mielomeningocele torácica/ Use of vertical expandable prosthetic of titanium for the rib for treating congenital kyphosis in thoracic meningomyelocele patients/ Uso de la prótesis vertical expansible de titanio para costilla en el tratamiento de la cifosis congénita en portadores de mielomeningocele torácico

Zuiani, Guilherme Rebechi; Cavali, Paulo Tadeu Maia; Santos, Marcus Alexandre Mello; Rossato, Alexander Junqueira; Lehoczki, Maurício Antonelli; Risso Neto, Marcelo Ítalo; Veiga, Ivan Guidolin; Pasqualini, Wagner; Landim, Élcio
2009-09-01

Resumo em português OBJETIVO: avaliar os resultados clínicos e radiográficos pós-operatórios da correção de cifose congênita em pacientes com mielomeningocele de nível torácico, utilizando a prótese vertical expansível de titânio para costela (VEPTR). MÉTODOS: estudo retrospectivo de 19 pacientes com mielomeningocele torácica e cifose congênita submetidos a tratamento com VEPTR, entre Outubro de 2005 e Outubro de 2008, com avaliação radiográfica e clínica pré e pós-opera (mais) tória imediata. Foram avaliadas também a duração do procedimento cirúrgico, a necessidade de transfusão sanguínea e as complicações pós-operatórias. RESULTADOS: a média de idade dos pacientes foi de 70 meses ou cinco anos e dez meses (32 a 130 meses). A média de seguimento dos pacientes foi de 13,5 meses (2 a 26 meses). A duração média do procedimento foi de 117 minutos (variação de 70 a 195 minutos). Todas as crianças adquiriram equilíbrio de tronco, sendo que 13 delas não apresentavam isto no pré-operatório. A média da cifose pré-operatória foi de 115° (80° a 150°) e pós-operatória de 77° (50° a 104°), com porcentagem média de correção de 31,2% (1,1 a 61,5%). O desequilíbrio do tronco pré-operatório foi de 7,9 cm, em média (1,0 a 15,5 cm) e pós-operatório de 3,4 cm (0 a 8 cm). A correção média desse desequilíbrio foi de 50,4% (0 a 100%). Com relação ao peso, no pré-operatório a média foi de 15,4 kg (8 a 30 kg), e no pós-operatório de 20,6 kg (8,5 a 35 kg). O ganho médio de peso foi de 36,6% (9,8 a 100%). Dos 19 pacientes, cinco (26,3%) apresentaram complicações pós-operatórias. Nenhum paciente necessitou de transfusão sanguínea. CONCLUSÃO: a utilização do VEPTR nos pacientes portadores de mielomeningocele torácica com cifose congênita tem se mostrado uma alternativa eficaz e promissora de controle da deformidade em pacientes esqueleticamente imaturos. Resumo em espanhol OBJETIVO: evaluar los resultados clínicos y radiográficos postoperatorios de la corrección de la cifosis congénita en pacientes con mielomeningocele de nivel torácico, utilizando la prótesis vertical expansible de titanio para costilla (VEPTR). MÉTODOS: estudio retrospectivo de 19 pacientes con mielomeningocele torácico y cifosis congénita sometidos al tratamiento con VEPTR, entre Octubre de 2005 y Octubre de 2008, con evaluación radiográfica y clínica, pre y (mais) postoperatorio inmediato. Fueron evaluadas también la duración del procedimiento quirúrgico, la necesidad de transfusión sanguínea y las complicaciones postoperatorias. RESULTADOS: el promedio de edad de los pacientes fue de 70 meses o 5 años y 10 meses (32 a 130 meses). El promedio de seguimiento de los pacientes fue de 13.5 meses (2 a 26 meses). La duración promedio del procedimiento fue de 117 minutos (variación de 70 a 195 minutos). Todos los niños adquirieron equilibrio del tronco, siendo que 13 no lo presentaban en el preoperatorio. El promedio de la cifosis preoperatorio fue de 115° (80° a 150°) y postoperatoria de 77° (50° a 104°), con porcentaje promedio de corrección de 31.2% (1.1 a 61.5%). El desequilibrio del tronco preoperatorio fue de 7.9 cm, en promedio (1.0 a 15.5 cm) y postoperatorio de 3.4 cm (0 a 8 cm). La corrección promedio de ese desequilibrio fue de 50.4% (0 a 100%). Con relación al peso, en el preoperatorio el promedio fue de 15.4 kg (8 a 30 kg), y en el postoperatorio de 20.6 kg (8.5 a 35 kg). La ganancia de peso en promedio fue de 36.6% (9.8 a 100%). De los 19 pacientes, cinco (26.3%) presentaron complicaciones postoperatorias. Ningún paciente necesitó transfusión sanguínea. CONCLUSIÓN: la utilización del VEPTR en los pacientes portadores de mielomeningocele torácico con cifosis congénita ha demostrado ser una alternativa eficaz y promisoria del control de la deformidad en pacientes esqueléticamente inmaduros. Resumo em inglês OBJECTIVE: to evaluate clinical and radiographic postoperative results of congenital kyphosis correction in thoracic meningomyelocele patients using vertical expandable prosthetic of titanium for the rib (VEPTR). METHODS: a retrospective study of 19 thoracic meningomyelocele and congenital kyphosis patients that were subjected to the VEPTR treatment between October 2005 and October 2008, with radiographic evaluation and immediate post and pre-operative clinical practice. (mais) Also, the duration of surgical procedure, the need for blood transfusion and postoperative complications were assessed. RESULTS: the patients' average age was 70 months (from 32 to 130 months). The average follow-up from patients was 13.5 months (from 2 to 26 months). The average duration of the procedure was 117 minutes (variation between 70 and 195 minutes). All children reached trunk balance, 13 of whom had not showed it in the postoperative period. The average of pre-operation kyphosis was 115° (from 80° to 150°) and 77° (from 50° to 104°) for postoperative, with an average correction percentage of 31.2% (from 1.1 to 61.5%). The previous pre-operative imbalance of trunk was an average 7.9 cm (from 1.0 to 15.5 cm) and 3.4 cm (from 0 to 8 cm) for post-operative. The average correction of this imbalance was of 50.4% (from 0 to 100%). Regarding weight, in pre-operative the average was 15.4 kg (from 8 to 30 kg) and 20.6 kg (from 8.5 to 35 kg) for postoperative. The average gain of weight was of 36.6% (from 9.8 to 100%). Five of the 19 patients (26.3%) presented postoperative complications. No patient needed blood transfusion. CONCLUSION: the use of VEPTR in thoracic meningomyelocele and congenital kyphosis patients has proven to be an effective and promising alternative for the control of physical deformity in patients with a potential for growth.

Scientific Electronic Library Online (Portuguese)

7

Hidrogenofosfato de titânio lamelar: síntese, troca iônica e intercalação/ Lamellar titanium hydrogenphosphate: synthesys, ion-exchange and intercalation

Nunes, Liliane M.; Airoldi, Claudio
2001-12-01

Resumo em inglês The development associated with the research field involving crystalline inorganic lamellar titanium hydrogenphosphate, Ti(HPO4).H2O, synthesized as alpha or gamma forms, is directly linked to the huge number of reactions, that occur inside the free interlamellar space. Two distinguishable well-characterized features such as ion-exchange and intercalation reactions are explored here. From the interactive point of view, the acidic OH centres distributed on the lamella can (mais) interact with cations or with basic polar molecules to exchange or to intercalate them. These chemical reactions are normally followed by an expansion of the interlamellar space, proportional to the amount intercalated, reflecting in ion radii or organic molecule size lengths used in ion-exchange or insertion processes, respectively. The effectiveness of the exchange increased when the original matrix has the proton of OH group previously ion-exchanged by an alkaline or an alkylammonium cations. Monoalkyl-, dialkyl- and heterocyclic amines are focused in this revision as clear and elucidative examples of acid-base interactive processes, that come out inside of the well-formed infinite sequence of inorganic lamellar structure.

Scientific Electronic Library Online (Portuguese)

8

Incorporação de dióxido de titânio em zeólitas para emprego em fotocatálise heterogênea/ Titanium oxide incorporation on zeolites for heterogeneous photocatalisis

Merg, Jean C.; Rossett, Franciele; Penha, Fábio G.; Pergher, Sibele B. C.; Petkowicz, Diego I.; Santos, João H. Z. dos
2010-01-01

Resumo em inglês This work proposes the study of heterogeneous photocatalysis using TiO2 impregnated in zeolites beta, ZSM-5, mordenite, NaXb, NaXp and NaY for the decomposition of methylene blue. The catalysts were characterized by XRD, IR, textural analyses by N2 adsorption, SEM, DRS and the reaction of decomposition was monitored by UV visible. The results indicated that didn't have structural changes in the catalysts after Ti impregnations, only in the case of NaY and NaX zeolites. Th (mais) e better photocatalyst to metylene blue decomposition was beta/Ti zeolite due had one structure more accessible (with bigger porous) helping in TiO2 dispersion and catalytic active.

Scientific Electronic Library Online (Portuguese)

9

Encapsulamento do Dióxido de Titânio (TiO2) pela Técnica de Polimerização em Emulsão/ Encapsulation of Titanium Dioxide (TiO2) by the Technique of Emulsion Polymerization

Oliveira, Adriano M.; Silva, Maria L.C.P.; Alves, Gizelda M.; Santos, Amilton M.
2002-01-01

Resumo em português Este trabalho apresenta uma metodologia de encapsulamento do TiO2 pela técnica de polimerização em emulsão. O pigmento foi previamente modificado por um titanato em heptano. O titanato usado foi o tri-isoestearato iso-propoxi de titânio, que reage com os grupos hidroxilas da superfície do TiO2. O pigmento modificado foi encapsulado por metacrilato de metila (MMA), usando persulfato de amônio como iniciador e dodecil sulfato de sódio (SDS) como emulsificante. A rea (mais) ção de encapsulamento foi conduzida em um reator de vidro encamisado, utilizando dois processos de polimerização diferentes: batelada e semi-contínuo. A caracterização do pigmento modificado foi feita pela técnica de Infravermelho com Transformada de Fourier (FTIR). Os rendimentos das reações de modificação e de encapsulamento foram determinados pela técnica de Análise Termogravimétrica (TGA). Resumo em inglês This work presents a methodology for encapsulation of TiO2 by emulsion polymerization. The pigment was previously modified by a titanate in heptane. The titanate used was isopropoxy titanium tri-isostearate, which reacts with the hydroxyl groups at the pigment surface. The modified pigment was encapsulated by methyl methacrylate (MMA), using ammonium persulfate as initiator and sodium dodecyl sulfate (SDS) as surfactant. The encapsulation reactions were carried out, using (mais) a jacketed glass reactor, through two different polymerization processes: batch and semi-continuous processes. The characterization of the modified pigment was made with FTIR spectroscopy. The modification and encapsulation efficiency was determined by means of TGA.

Scientific Electronic Library Online (Portuguese)

10

Extração líquido-líquido de ferro(III) e titânio(IV) pelo ácido bis-(2-etil-hexil) fosfórico (D2EHPA) em meio de ácido sulfúrico/ Liquid-liquid extraction (LLE) of Fe(III) and Ti(IV) by bis-(2-ethyl-hexyl) phosphoric acid (D2EHPA) in sulfuric acid medium

Silva, Glauco Corrêa da; Cunha, José Waldemar Silva Dias da; Dweck, Jo; Afonso, Julio Carlos
2008-01-01

Resumo em inglês This work presents a study on the separation of Fe(III) and Ti(IV) from sulfuric acid leaching solutions of ilmenite (FeTiO3) using liquid-liquid extraction with D2EHPA in n-dodecane as extracting agent. The distribution coefficients (K D) of the elements related to free acidity and concentration of Fe(III) and Ti(IV) were determined. Free acidity was changed from 3x10-2 to 11.88 mol L-1 and D2EHPA concentration was fixed at 1.5 mol L-1. Recovery of final products as well (mais) as recycling of wastes generated in the process were also investigated. The LLE process as a feasible alternative to obtain high-purity TiO2.

Scientific Electronic Library Online (Portuguese)

11

Ligadura com algodão e com grampos de titânio em artérias de cães: estudo experimental em máquina simuladora de pressão/ Aterial titanium clip and stitch ligation in dogs: experimental study in a pump machine

Soares, Adriano Leite; Goldenberg, Saul; Novo, Neil Ferreira; Lima, Cirilo Antônio de Paula
2001-12-01

Resumo em português O desenvolvimento da cirurgia video-laparoscópica trouxe a necessidade de tornar convencional a ligadura artérial com grampos de titânio para a diminuição do tempo operatório. Com o objetivo de investigar e comparar a ligadura artérial com algodão zero e com um, dois e três grampos de titânio, foram utilizadas 80 artérias de 20 cães da espécie Canis Familiaris. De cada cão, utilizaram-se as artérias axilares direita e esquerda e femorais direita e esquerda, (mais) que foram distribuídas em quatro grupos, mediante sorteio prévio e rodízio. Após a dissecção artérial e ligadura, as artérias foram submetidas a uma pressão de 100 mmHg e de 300 mmHg, e a uma pulsação de 70 batimentos por minuto, conseguida por meio de uma máquina simuladora da pressão artérial. Houve extravasamento em três artérias, todas pertencentes ao grupo de ligadura com um grampo de titânio. Este extravasamento é estatisticamente significante e ocorreu em até 15 minutos após o início de funcionamento da máquina. Com os resultados, conclui-se que a ligadura artérial com um grampo de titânio tem maior probabilidade de extravasar do que a ligadura com dois ou três grampos de titânio, e a ligadura com fio de algodão zero, em cães. Não há diferença entre a ligadura artérial com fio de algodão e com dois ou três grampos de titânio, quando submetidas a pressão de 300 mmHg e pulsação de 70 batimentos por minuto, em cães. Resumo em inglês The development of the video laparoscopic surgery has brought the necessity of standardizing the artery ligation with titanium clips in order to minimize operation time. The aim of this study is to investigate and compare the arterial ligation with cotton thread, and also with one, two or three titanium clips. Consequently, eigthy arteries of twenty mongrel’s dogs were utilized. Each of the dog had their right and left axillary arteries, as well as the rigth and left fem (mais) oral arteries used. Those arteries had been previously distributed in 4 groups, being previously chosen by lot and in turns. After arterial dissection and ligation, the arteries were submitted to 100 mmHg and 300 mmHg of pressure, and a pulsation rate of 70 bumps per minute, that was obtained by an arterial pressure simulation machine. There was a liquid escape from 3 arteries, which belonged to the one-titanio-clip group. This escape, that is statistically significant occurred in less than 15 minutes. Furthermore, the results show that the arterial ligation with one titanio clip has a great probability of escaping, contrary to the ligation done with cotton thread, as well as the ones done with two or three titanium clips. Therefore, there is no difference between the ligation with cotton thread and two or three titânio clips, if they are submited to 300 mmHg of pressure and a pulsation rate of 70 bumps per minutes.

Scientific Electronic Library Online (Portuguese)

12

Otimização das superfícies dos implantes: plasma de titânio e jateamento com areia condicionado por ácido - estado atual/ Optimization of implant surfaces: titanium plasma spray and acid-etched sandblasting - current state

AMARANTE, Evandro Scigliano; LIMA, Luiz Alves de
2001-06-01

Resumo em português O objetivo deste trabalho foi analisar os resultados da literatura publicada sobre superfícies de implantes tratadas com plasma de titânio (TPS) e jateadas com areia e tratadas com ácido (SLA). Isoladamente, a textura da superfície foi a característica mais marcante na promoção da osseointegração. Os estudos da topografia da superfície implantar no comportamento celular mostraram que o osso se deposita indistintamente em superfícies porosas ou lisas, seja em im (mais) plantes de cerâmica, titânio, ou em ampla variedade de outras superfícies. A porosidade portanto, não é condição necessária para que ocorra aposição óssea, entretanto, desempenha um papel preponderante no percentual de aposição óssea sobre a superfície do implante, assim como na velocidade com que essa deposição ocorre. Nesta revisão destacou-se uma promissora superfície denominada SLA, tratada com jatos de areia (partículas pequenas) seguida de ataque ácido. Os resultados demonstraram que tanto a rugosidade como o tratamento químico das superfícies podem influenciar bastante a força superficial de cisalhamento (resistência oferecida à remoção). Estas características da superfície do titânio, além de otimizar o procedimento, podem ainda, por exemplo, permitir a colocação dos implantes em função mais precocemente e ampliar a gama de aplicações possíveis para osso alveolar de densidade inferior, ou favorecer sua aplicação em osso regenerado. Resumo em inglês The aim of this review was to update the concepts regarding the preparation of the surfaces of titanium implants, focusing on TPS (titanium plasma-sprayed implants) and SLA (sandblasted and acid etched implants). Texture was the most remarkable isolated feature, regarded as an osseointegration promoter. In a comprehensive review of the effects of implant surface topography on cell behavior, one can verify that there is bone apposition onto the implant surface regardless o (mais) f its characteristics: polished or rough, made of titanium or ceramic. Roughness is not mandatory for bone apposition. However, it has been shown that roughness may play an important role in the percentage of bone apposition as well as in the velocity of apposition. In this review, a quite promising type of surface called SLA is pointed out, showing that either roughness or acid conditioning of the surfaces can significantly improve shear strength. Besides optimizing the procedure, these surface characteristics may, eventually, allow for an earlier loading of the implant and extend the indications for implants in low-density alveolar bone and in regenerated bone.

Scientific Electronic Library Online (Portuguese)

13

Avaliação da superfície de braquetes de titânio após a aplicação de fluoreto de sódio/ Evaluation of titanium brackets surface after immersion in sodium fluoride

Menezes, Luciane Macedo de; Lima, Eduardo Martinelli S. de; Rizzatto, Susana Maria Deon; Thiesen, Guilherme; Rego, Marcus Vinicius Neiva Nunes do; Cumerlato, Marina Lúcia; Zardo, Patrícia
2006-06-01

Resumo em português OBJETIVO: avaliar o efeito da aplicação do fluoreto de sódio (NaF 1,23%) sobre a superfície de braquetes de titânio e de aço inoxidável. METODOLOGIA: foram utilizados 15 braquetes de titânio, divididos em três grupos: A) grupo controle, composto por braquetes não submetidos a qualquer tipo de tratamento; B) braquetes imersos por 60 segundos em fluoreto de sódio e lavados com 20ml de água destilada por trinta segundos; C) braquetes imersos por 60 segundos em fl (mais) uoreto de sódio e posteriormente submetidos à escovação por 15 segundos, sendo então lavados com 20ml de água destilada por trinta segundos. Para efeito comparativo, foram utilizados 15 braquetes de aço inoxidável, divididos em três grupos (Grupos A1, B1, C1) e submetidos aos mesmos procedimentos descritos. Todos os braquetes, antes e após o experimento, foram avaliados por inspeção visual e analisados ao microscópio eletrônico de varredura (Philips, modelo XL 30). RESULTADOS: a inspeção visual revelou uma mudança da coloração dos braquetes de titânio submetidos ao fluoreto de sódio (grupos B e C), apresentando-se escurecidos quando comparados aos acessórios do grupo A. Os braquetes de aço inoxidável não sofreram alteração cromática em nenhum dos grupos. CONCLUSÃO: através da análise por microscópio eletrônico de varredura, não foram constatadas alterações topográficas e químicas na superfície dos braquetes de titânio, assim como nos braquetes de aço inoxidável. Resumo em inglês AIM: to assess and compare the effects of fluoride (NaF 1.23%) on titanium and stainless steel brackets. METHODS: Fifteen titanium brackets, divided in 3 groups were used: A) control group (no treatment on its surface), B) brackets immersed in NaF (60 seconds) and washed with distilled water (30 seconds), C) brackets with similar treatment to group B and submitted to brushing (15 seconds). Fifteen stainless steel brackets were used for comparative effects, divided in 3 gr (mais) oups, and submitted to the same described procedures. All brackets were evaluated by macroscopic (visual appearence) and scanning microscopy (Philips, model XL 30), before and after the procedures. RESULTS: titanium brackets submitted to fluoride (NaF), groups B and C, presented discoloration (matte gray color) when compared to group A. Stainless steel brackets showed no color alteration. CONCLUSION: titanium and stainless steel brackets showed no change in surface roughness or chemical components when immersed in sodium fluoride solution.

Scientific Electronic Library Online (Portuguese)

14

Reconstrução de ponte nasal com tela de titânio após exérese tumoral em um cão/ Nasal bridge reconstruction with titanium mesh after tumor excision in a dog

Krüger, Renan Marcel; Colomé, Lucas Marques; Müller, Daniel Curvello de Mendonça; Gomes, Cristiano; Amaral, Anne Santos do
2011-03-01

Resumo em português O presente trabalho relata o uso de tela de titânio como alternativa para reconstrução do defeito ósseo criado pela ressecção agressiva de carcinoma de células escamosas da ponte nasal em cão. Após o tratamento quimioterápico com 5-fluorouracil tópico e sistêmico associado à piroxicam para a redução da massa tumoral, foi realizada a ressecção cirúrgica da região comprometida e reparo do defeito ósseo com tela de titânio e posterior recobrimento com re (mais) talho músculo-cutâneo unipediculado de avanço. A principal complicação no período pós-operatório foi a formação de enfisema subcutâneo, controlado em três dias com drenagem do ar e aplicação de bandagens compressivas. O animal permaneceu sem sinais de recidiva por oito meses. No décimo mês pós-operatório, o paciente apresentou miíase no local da recidiva e a proprietária optou pela eutanásia. Com esse caso, foi possível concluir que a tela de titânio foi um material adequado para a reconstrução da ponte nasal, tendo como principal complicação a ocorrência de enfisema subcutâneo. Resumo em inglês This paper describes the use of titanium mesh as an alternative for reconstruction of bone defect created by resection of aggressive squamous cell carcinoma of the nasal bridge in a dog. After chemotherapy with topic and systemic 5-fluorouracil associated with piroxicam for the tumor mass reduction, it was performed a surgical resection of the affected region, repair of bone defects with titanium mesh and subsequent closing of the wound with musculocutaneous single pedicl (mais) e advancement flap. The main complication in the postoperative period was the formation of subcutaneous emphysema, which was controlled in three days with air drainage and application of compression bandages. The animal remained without signs of recurrence for eight months. In the tenth month postoperatively, the patient presented myiasis in local recurrence and the owner opted for euthanasia. In this case, it was possible to conclude that titanium mesh was a suitable material for the reconstruction of the nasal bridge, having as main complication the occurrence of subcutaneous emphysema.

Scientific Electronic Library Online (Portuguese)

15

Recobrimento de apatitas "in vitro" sobre titânio: influência do tratamento térmico/ Apatites coating "in vitro" on titanium: influence of the thermal treatment

Vercik, L. C. de O.; Assis, C. M. de; Fook, M. V. Lia; Santos, M. L. dos; Guastaldi, A. C.
2003-01-01

Resumo em português Titânio comercialmente puro, Ti-cp, e algumas de suas ligas são consideradas muito importantes na área médica devido sua excelente biocompatibilidade e propriedades mecânicas. Recentemente, foi desenvolvido um método químico, relativamente simples, para induzir a bioatividade desses materiais metálicos inertes, cujo princípio é imitar as condições biológica para obtenção do material desejado. Esta técnica denominada biomimético, foi utilizada para modific (mais) ar a superfície do Ti-cp através do depósito de uma camada de apatita. O objetivo principal deste trabalho foi estudar a influência do tratamento térmico na evolução da cristalinidade das fases depositadas. Os recobrimentos de apatitas, com tratamentos térmicos entre 400 e 600 ºC, mostraram através das técnicas de difração de raios-X e microscopia eletrônica de varredura, uma baixa cristalinidade semelhante às apatitas biológicas. Acima de 700 ºC, os recobrimentos de apatita mostraram-se mais cristalinos apresentando uma mistura de fases de hidroxiapatita, fosfato octacálcico e fosfato de magnésio. Resumo em inglês Commercially pure titanium (cp-Ti), and some of its alloys are considered very important in the medical field because of its excellent biocompatibility and mechanical properties. Recently a simple chemical method was introduced to induce the bioactivity of these inert metallic materials. In this work, the biomimetic chemical process has been used to modify the cp-Ti surface with the deposit of a layer of apatite. The main objective consisted in studying the influence of t (mais) he thermal treatment on the evolution of the crystallinity of the deposited phases. X-ray diffraction and scanning electron microscopy techniques showed that the apatite coatings with thermal treatments between 400 and 600 ºC presented low crystallinity similar to the biological apatites. Above 700 ºC, the apatite coatings appeared more crystalline, exhibiting a mixture of hydroxyapatite, octacalcium phosphate and magnesium phosphate.

Scientific Electronic Library Online (Portuguese)

16

Fotocatálise eletroquímica de atrazina sobre dióxido de titânio: efeito de diferentes parâmetros experimentais/ Photoelectrochemical degradation of atrazina on titanium dioxide: effect of different experimental parameters

Santana, Henrique de; Bonancêa, Carlos Eduardo; Takashima, Keiko
2003-12-01

Resumo em inglês The atrazine photoelectrochemical degradation has been examined in solutions containing TiO2 on immobilized films under a variety of experimental conditions. It was possible to observe that the supporting electrolyte nature affects the intensity of the photocurrent, being an indicative of the adsorption process. The disappearance of the organic molecule follows approximately a pseudo-first order kinetic. As mineralization product, NH4+ and NO3- ion have been identified. T (mais) hese results indicated that the formation of NH4+ ion can be associated to the effect of atrazine adsorption, due to need of potential adaptation together with a variation in the supporting electrolyte concentration.

Scientific Electronic Library Online (Portuguese)

17

Avaliação das fases cristalinas de dióxido de titânio suportado em cerâmica vermelha/ Evaluation of the crystalline phases of supported titanium dioxide in red ceramic

Saleiro, G. T; Cardoso, S. L; Toledo, R; Holanda, J. N. F
2010-06-01

Resumo em português O dióxido de titânio apresenta boas propriedades como um material fotocatalisador para aplicação em processos de degradação fotocatalítica. No entanto, o dióxido de titânio deve ser usado ancorado num suporte adequado. O uso de cerâmica vermelha como suporte de fotocatalisadores pode ser uma boa alternativa devido ao seu baixo custo e facilidade de fabricação. Neste trabalho foi estudado, via difração de raios X, o dióxido de titânio suportado em cerâmica (mais) vermelha produzida com argilas cauliníticas da região de Campos dos Goytacazes, RJ. Os resultados mostram que o dióxido de titânio apresenta mudança estrutural da fase mais fotoativa (anatásio) para a fase menos fotoativa (rutilo) com o aumento da temperatura de sinterização. Em 700 ºC cerca de 50% da fase anatásio é retida para o dióxido de titânio suportado em cerâmica vermelha, independentemente do tipo de argila usada. Resumo em inglês The titanium dioxide presents good properties as a photocatalyst material for application in processes of photocatalytic degradation. However, the titanium dioxide should be anchored on a suitable support. The use of red ceramic as supporting material can be an alternative very interesting due to the its low cost and ease of manufacturing. In this work was studied via X-ray diffraction the phase transformation anatase-rutile at different temperatures for supported titaniu (mais) m dioxide in red ceramic substrate prepared with kaolinitic clays from the Campos dos Goytacazes-RJ region. The results showed that the effect of the sintering temperature was promoting the structural change of the phase more photoactive (anatase) for the less photoactive (rutile). At 700 ºC about 50% of the anatase phase is retained for supported titanium dioxide in red ceramic substrate, independently of the clay type used.

Scientific Electronic Library Online (Portuguese)

18

Influência do método de síntese no processo de pilarização com titânio de uma esmectita da região amazônica/ Influence of the synthesis method on the process of pillarization of smectite from the amazonic region with titanium

Guerra, D. L.; Lemos, V. P.; Angélica, R.; Airoldi, C.
2006-12-01

Resumo em português Amostras de argila esmectítica provenientes do município de Serra Madureira no Estado do Acre foram utilizadas no processo de pilarização. As matrizes natural e pilarizada foram caracterizadas por difração de raios X, espectroscopia no infravermelho com transformada de Fourier, análises térmicas diferencial e gravimétrica, microscopia eletrônica de varredura, espectroscopia de raios X por energia dispersiva e análise textural. As soluções pilarizantes de tit� (mais) �nio, Ti(OC2H5)4 e TiCl4, foram analisadas por espectroscopia no infravermelho com transformada de Fourier. O íon intercalante foi obtido através da reação química entre as soluções de Ti(OC2H5)4 e HCl na proporção aproximada de HCl/Ti=1 e soluções de TiCl4 em reação com etanol com relação Ti/argila= 25 mmol Ti/g. A intercalação da notronita foi efetuada utilizando-se de dois métodos: com a solução de acido clorídrico incorporada paulatinamente na solução de etóxido de titânio, e utilizando o cloreto de titânio em solução de etanol, com vigorosa agitação a 25 ºC durante 3 h e com calcinação a 450 ºC e 600 ºC. Os resultados de difração de raios X do processo de pilarização mostraram alterações no espaçamento basal de 15,30 Å para 18,76 Å, e na área de superfície específica de 44,37 m²/g para 188,72 m²/g. A estabilidade térmica da argila natural foi otimizada com o processo de pilarização. Resumo em inglês Smectite clays of the State of Acre, Brazil, were used for the pillarization process. The natural and pillarized matrices were characterized by X-ray diffraction, Fourier transform infrared spectroscopy (FTIR), thermal analysis, scanning electron microscopy, energy dispersive spectroscopy and textural analysis. The titanium pillarized solutions Ti(OC2H5)4 and TiCl4 were analyzed by FTIR. The intercalation ion was obtained by reacting Ti(OC2H5)4 with HCl (HCl/Ti ~ 1) and T (mais) iCl4 with ethanol (Ti/clay ~ 25 mmol Ti/g). The notronite intercalation was carried out using two methods: with dropwise hydrochloric acid in titanium ethoxide solution, and using titanium tetrachloride, kept under vigorous stirring at 25 °C for 3 h and calcination at 450 °C and 600 °C. The X-ray diffraction results of the pillarization process show an increase (15.30 Å to 18.76 Å) in the basal spacing of the natural clay and in the specific surface area (44.37 m²/g to 188.72 m²/g) The thermal stability of the natural clay was improved by the pillarization procedure.

Scientific Electronic Library Online (Portuguese)

19

Alternativas analíticas para determinação de ferro e titânio em cimento Portland/ Comparative study of analytical methods for iron and titanium determination in Portland cement

Franco Jr., Jorge de O.; Korn, Maria das Graças A.; Costa, Antonio Celso S.; Santos Jr., Anibal de Freitas; Teixeira, Leonardo S. G.
2001-04-01

Resumo em inglês In the present work four different analytical methodologies were studied for the determination of iron and titanium in Portland cement. The cement samples were dissolved with hot HCl and HF, being compared Fe and Ti concentrations through four analytical methods: molecular absorption spectrophotometry using the reagents 1,2-hydroxybenzene-3,5-disulfonic acid (Tiron) and the 5-chloro-salicylic acid (CSA), inductively coupled plasma atomic emission spectrometry (ICP-AES) an (mais) d flame atomic absorption spectrophotometry (FAAS). In the spectrophotometric determinations were studied pH conditions, reagents addition order, interferences, amount of reagents, linear range and stability of the system. In the techniques of ICP-AES and FAAS were studied the best lines, interferences, sensibility and linear range. The obtained results were compared and the agreement was evaluated among the methods for the determination of the metals of interest.

Scientific Electronic Library Online (Portuguese)

20

Análise comparativa em modelo computadorizado bidimensional com simulação do emprego de hastes flexíveis de aço e titânio, na fratura do fêmur da criança, utilizando o método dos elementos finitos/ Comparative analysis in a 2D computer model simulating the use of steel and titanium elastic nails in pediatric femur fracture, using the finite element method

Soni, Jamil Faissal; Santili, Cláudio; Lancellotti, Carmen Lucia Penteado; Hecke, Mildred Balin; Almeida, Felipe Recka de; Karam, Leandro Zen
2008-05-01

Resumo em português OBJETIVO: Apresentar um modelo computadorizado bidimensional, simulando uma fratura do fêmur em criança tratada por hastes flexíveis de aço e titânio, utilizando o método dos elementos finitos, avaliando-se comparativamente o caminho e distribuição das tensões, tensões principais e deformações. MÉTODOS Foram utilizados dois modelos diferentes, gerados pelo aplicativo Ansys®, considerando a simulação de uma fratura transversal na região diafisária, com a (mais) espessura de 1mm, cuja estabilização foi feita mediante o emprego de hastes intramedulares de materiais diferentes (aço e titânio), à luz da teoria mecanostática proposta por Frost, em 1987. RESULTADOS: A introdução das hastes intramedulares no fêmur alterou o caminho das tensões, servindo como condutoras das forças compressivas. Na análise comparativa, o modelo com as hastes de titânio, à luz da teoria mecanostática proposta por Frost, apresentou desempenho mais homogêneo quando do estudo das deformações em relação ao modelo com hastes de aço inoxidável. CONCLUSÕES: O modelo proposto atingiu os objetivos de comparar as tensões e deformações entre as simulações das hastes de aço e titânio. Analisando o caminho e distribuição das tensões no modelo (Von Mises e tensões principais), observa-se comportamento biomecânico qualitativamente melhor no modelo com hastes de titânio; todavia, na análise quantitativa, restrita às regiões do foco de fratura, os valores são estatisticamente semelhantes. No estudo das deformações, observa-se comportamento biomecânico mais homogêneo no modelo com hastes de titânio, pois as deformações verificadas nas regiões do foco de fratura apresentam-se dentro das janelas fisiológicas propostas por Frost. Resumo em inglês OBJECTIVE: To present a 2D computer model simulating a pediatric femur fracture treated with steel and titanium elastic nails, using the Finite Element Method, with a comparative evaluation of the paths and distribution of stresses, main stresses, and strains. METHODS: Two different models were used, both generated by application Ansys®, considering the simulation of a 1 mm transversal fracture of the diaphysis whose stabilization was performed with the use of intramedul (mais) lary nails made of different materials (steel and titanium), according to the Mechanostat Theory proposed by Frost in 1987. RESULTS: The introduction of intramedullary nails in the femur has changed the path of stresses, and conducted compressive stresses. In the comparison, the model with titanium nails, according to the Mechanostat Theory proposed by Frost, presented a more homogenous performance in the strain study than the stainless steel nails. CONCLUSIONS: The model proposed attained the objective of comparing stresses and strains between the steel and titanium nails simulations. By analyzing the path and the distribution of stresses in the model (Von Mises and main stresses), one can see the qualitatively improved biomechanical behavior in the titanium nails model, but in the quantitative analysis restricted to the fracture focus regions, the values are statistically similar. In the strain study, the more homogenous biomechanical behavior is seen in the model with titanium nails, as all strains seen in fracture focus regions are within the physiological window proposed by Frost.

Scientific Electronic Library Online (Portuguese)

21

Estudo químico, macroscópico e da resistência à flexão de placas e parafusos de titânio usados na fixação interna rígida/ Chemical, macroscopical and bending resistance study of titanium plates and screws used in internal rigid fixation

TRIVELLATO, Alexandre Elias; MAZZONETTO, Renato; PASSERI, Luis Augusto; CONSANI, Simonides
2000-12-01

Resumo em português O objetivo deste estudo foi comparar quatro sistemas de placas e parafusos de titânio de 2,0 mm de diâmetro utilizados em fixação interna rígida, sendo duas marcas nacionais (Engimplan e Bucomax) e duas importadas (Synthes e W. Lorenz). Foram realizadas as seguintes análises: composição química, através de espectrometria por dispersão de energia (EDS) e espectrometria de emissão atômica (AES), macroscópica, por meio de medidas padronizadas e de resistência (mais) à flexão. Os resultados obtidos permitem concluir que as marcas nacionais apresentaram um comportamento inferior, em relação a padronização das dimensões das placas e parafusos avaliados, influenciando nos resultados dos testes de flexão, para os quais estas se comportaram da mesma maneira. Entretanto, a marca comercial W. Lorenz utiliza liga de titânio-6alumínio-4vanádio para a confecção dos parafusos, fato responsável pelo melhor resultado no teste de flexão que qualquer outra marca. Os demais parafusos e placas apresentaram-se constituídos de titânio comercialmente puro, de acordo com a EDS e posteriormente confirmados pela AES. Resumo em inglês The aim of this study was to compare four systems of titanium plates and screws (diameter of 2.0 mm) used for internal rigid fixation. From them, two were made in Brazil (Engimplan and Bucomax), one in Switzerland (Synthes), and the other, in Germany (W. Lorenz). The following analyses were done: chemical analysis using Energy Dispersive Spectroscopy (EDS) and Atomic Emission Spectroscopy (AES), measurement of dimensions and bending resistance test. The obtained results a (mais) llow to conclude that both Brazilian systems showed inferior behavior regarding dimensional standards. The bending assay showed that the Brazilian systems are similar to each other. However, the W. Lorenz screws are made of titanium-6aluminum-4vanadium alloy, which can be the reason for their better performance in the bending assay, when compared with that of the other three systems. The remaining plates and screws are made of commercially pure titanium as confirmed by EDS and AES.

Scientific Electronic Library Online (Portuguese)

22

Polimerização 1,4 - cis de butadieno com o sistema catalítico tetracloreto de titânio/triisobutilalumínio/iodo/ 1,4 cis-Polymerization of butadiene by the catalyst system titanium tetrachloride/triisobutylaluminium/iodine

Pires, Neusa M. T.; Costa, Marcos A. S.; Coutinho, Fernanda M. B.
2000-12-01

Resumo em português Foi utilizado o sistema catalítico tipo Ziegler-Natta modificado, constituído por TiCl4/I2/Al(i-Bu)3 para a síntese de polibutadieno com alto teor de unidades 1,4-cis. Foi estudada a influência da variação da composição do sistema catalítico e da temperatura reacional na atividade catalítica, no massa molar e na microestrutura do polibutadieno. Os polímeros foram caracterizados por espectroscopia na região do infravermelho, cromatografia por exclusão por tama (mais) nho e calorimetria diferencial de varredura. Foi obtido polibutadieno com até 92% de unidades 1,4-cis e baixo teor de gel. A massa molar ponderal média variou, com a composição do sistema catalítico e com a temperatura reacional, na faixa de 3 a 50 x 10(4) e a polidispersão variou na faixa de 1,8 a 3,3. A atividade catalítica máxima foi obtida para as razões molares Al/Ti = 5 e I2/Ti = 2. Resumo em inglês A modified Ziegler-Natta type catalytic system consisting of TiCl4/I2/Al(i-Bu)3 was used to produce polybutadiene with high content of 1,4-cis repeating units. The influence of the catalytic system composition and temperature on the catalyst activity, molecular weight and microstructure of the polybutadiene was studied. The polymers were characterized by infrared spectroscopy and size exclusion chromatography. Polybutadiene with up to 92% of 1,4-cis repeating units and lo (mais) w gel content was produced. The polymer molecular weight was dependent on the catalytic system composition and reaction temperature. The weight-average molecular weight varied from 3 to 50 x 10(4); the molecular weight distribution was low, ranging, from 1.8 to 3.3. The maximum catalytic activity was achieved at molar ratios Al/Ti = 5 and I2/Ti = 2.

Scientific Electronic Library Online (Portuguese)

23

Influência do agente de união na resistência ao cisalhamento da interface titânio/polímero de vidro/ Bonding agent influence on shear bond strength of titanium/polyglass interface

Oyafuso, Denise Kanashiro; Bottino, Marco Antonio; Itinoche, Marcos Koiti; Nasraui, Anna Paula; Costa, Elza Maria Valadares da
2003-09-01

Resumo em português Há poucas informações em relação à efetividade da união entre compósitos e superfícies metálicas. Este estudo avaliou a influência de dois agentes de união na resistência ao cisalhamento da interface formada pelo titânio comercialmente puro (Ti cp) e um compósito (Artglass/ Heraeus Kulzer). Vinte estruturas metálicas (4mm de diâmetro e 5mm de altura) de titânio grau 1 foram fundidas, jateadas com partículas de óxido de alumínio (250ìm) e separadas em (mais) dois grupos. Para cada grupo foi utilizado um agente de união (Sistema Siloc-Pre ou Retention Flow) como procedimento anterior à aplicação do material opaco. Sobre este foram aplicados camadas do polímero referente à dentina com o auxílio de uma matriz de teflon. A manipulação e polimerização foram realizadas de acordo com as recomendações do fabricante. Os corpos-de-prova foram armazenados em água destilada por 24 horas à 37ºC e termociclados (5º e 55ºC/ 500ciclos). O teste de resistência ao cisalhamento foi realizado em uma máquina de ensaios universal (Instron) com velocidade de 5mm/min. Os dados foram tratados estatisticamente pela Análise de Variância one-way (á=0,5). Os resultados indicaram que o sistema adesivo Retention Flow foi estatisticamente melhor do que o Siloc, com médias de 20,74MPa e 11,65MPa, respectivamente. Foi possível concluir que o sistema de união influenciou na adesão entre o titânio grau I e o polímero de vidro estudado. Resumo em inglês There is little information regarding bond strengths of polyglass to metal alloys. This study evaluated the influence of bonding system on shear bond strength of a composite resin (Artglass/Heraeus Kulzer) to cast titanium (Ti). Twenty metallic structures (4mm in diameter, 5mm thick) of titanium grade I were cast shaped and abraded with 250mm aluminum oxide and separated into two groups. For each group was applied one bonding system (Siloc or Retention Flow) before opaque (mais) and dentin polymer superposition. This procedure was managed using teflon matrices. They were manipulated and polymerized according to the manufacturer's recommendations. The samples were stored in distilled water for 24 hours at 37º and thermocycled (5º and 55ºC/500 cycles). Shear bond strength tests were performed by using an Instron Universal testing machine at a crosshead speed of 5mm/min. Results were analyzed statistically with one-way ANOVA (a=0,5) and they indicated that the Retention Flow system was statistically better than Siloc (20.74 MPa and 11.65 MPa , respectively). It was possible to conclude that the bonding agent influenced the adhesion between polymer and cast titanium.

Scientific Electronic Library Online (Portuguese)

24

Influência do espaçamento do feixe de laser Nd: YAG na obtenção de óxidos e nitretos na superfície do titânio em pressão atmosférica/ Influence of the Nd: YAG laser beam spacing in obtaining oxides and nitrides on titanium surface at atmospheric pressure

Filho, E.A.; Fraga, A.F.; Bini, R.A.; Marques, R.F.C.; Guastaldi, A.C.
2009-08-01

Resumo em português Neste trabalho investigou-se a modificação de superfície do titânio pela irradiação com feixe de Laser Nd:YAG. Os parâmetros do laser como a potência, o comprimento de onda, a frequência, a velocidade de varredura e a área de exposição foram mantidos constantes, exceto o espaçamento da matriz, o qual foi de 0,01 e 0,02 mm. A caracterização da superfície foi realizada por Microscopia Eletrônica de Varredura (MEV) e Difração de Raios X (DRX), sendo que os (mais) espectros foram refinados pelo método Rietveld. Pela análise de MEV, observou-se uma mudança na topografia, obtendo uma superfície rugosa produzida pelo fenômeno de ablação. As análises por Rietveld dos espectros de difração de raios X detectaram TiN, Ti2N, TiO2 (anatásio e rutilo), sendo que a amostra com espaçamento 0,01 mm apresentou uma maior quantidade de óxidos e nitretos. Isso pode ser devido à sobreposição do feixe, induzindo à formação de uma superfície com maior estabilidade termodinâmica. Os óxidos e nitretos obtidos são de grande importância, pois são responsáveis por produzir uma maior interação entre o osso-implante. Resumo em inglês In this work the titanium surface modification by Laser Nd:YAG irradiation was investigated. Laser parameters such as power, wavelength, frequency, scanning speed and the exposure area were maintained constant, except the matrix spacing, which was equal 0,01 and 0,02 mm. Characterization was carried out by Scanning Electron Microscopy (SEM) and X-Ray Diffraction (XRD) analysis, for which the spectra were refined by the Rietveld method. In the analysis by SEM, a change in (mais) the topography was observed, with a rough surface obtained by ablation phenomenon. The Rietveld analysis of the spectra presented the phases TiN, Ti2N, TiO2 (anatase and rutile), and the sample with spacing equal to 0,01 mm presented a larger amount of oxides and nitrides. This may be due to the beam overlapping, which induces a surface with larger thermodynamic stability. The oxides and nitrides are of great importance, because they are responsible for producing a satisfactory interaction between the bone and the implant.

Scientific Electronic Library Online (Portuguese)

25

Obtenção de filmes espessos de seleneto de cobre sobre carbono vítreo, ouro, titânio e cobre/ Obtaining copper selenide thick films on vitreous carbon, gold, titanium and copper

Rabelo, Adriano César; Arantes, Tatiane Moraes; Bottecchia, Otávio Luiz
2007-04-01

Resumo em inglês Copper selenide (berzelianite) films were prepared on the title substrates using the chemical bath deposition technique (CBD). Film composition was determined by energy dispersion of x-rays. The kinetics of film growth is parabolic and film adherence limits the film thickness. On titanium, copper selenide forms islands that do not completely cover the surface, unless the substrate is prepared with a tin oxide layer; film composition also depends on the titanium oxide laye (mais) r. On vitreous carbon, CBD and mechanical immobilization techniques lead to films with similar resistances for the electron transfer across the film/substrate interface. On gold, composition studies revealed that film composition is always the same if the pH is in the range from 8 to 12, in contrast to films prepared by an ion-ion combination route. On copper, a new procedure for obtaining copper selenide films as thick as 5 µm has been developed.

Scientific Electronic Library Online (Portuguese)

26

Fotodegradação de hidrocarbonetos policíclicos aromáticos em placas de sílica impregnadas com dióxido de titânio/ Photodegradation of polycyclic aromatic hydrocarbons (PAHs) adsorbed onto silica gel chromatographic plates impregnated with TiO2

Xavier, Laura Furquim Werneck; Moreira, Isabel Maria N. S.; Higarashi, Martha M.; Moreira, Josino C.; Ferreira, Luiz Filipe V.; Oliveira, Anabela S.
2005-06-01

Resumo em inglês Photodegradation of the PAHs anthracene, chrysene and benzo[k]fluoranthane on silica gel impregnated with TiO2 and over glass plates holding TiO2 was studied. Silica gel plates holding these substances were exposed to solar radiation, developed with hexane and photographed under ultra-violet light. The plates containing benzo[k]fluoranthene were also analysed by both diffuse reflectance and laser induced fluorescence. Diffuse reflectance spectra of the fluorescent spot fr (mais) om non irradiated plates showed small differences when compared with those obtained from irradiated plates. These spectral differences are compatible with formation of less conjugated compounds during irradiation. Fluorescence and time resolved fluorescence spectra observed after irradiation were identical to those obtained with benzo[k]fluoranthene in methanol. On plates holding silica, PAH degradation requires longer periods of solar irradiation when compared with those plates containing silica impregnated with TiO2. Glass plates impregnated with TiO2 also showed very rapid PAH degradation.

Scientific Electronic Library Online (Portuguese)

27

Efeitos dos parâmetros operacionais na fotodegradação do azo corante direct red 23 na interface dióxido de titânio/água/ Effects of operational parameters on the photodegradation of direct red 23 azo dye at the titanium dioxide/water interface

Clausen, Débora Nobile; Takashima, Keiko
2007-01-01

Resumo em inglês The decolorization and degradation of direct red 23 azo dye have been investigated in aqueous suspension of titanium dioxide under artificial irradiation. The effects of some operational parameters such as azo dye concentration, catalyst loading, and solution pH were investigated at 30.0 ºC and optimized values were obtained. The first-order kinetic model was used to discuss the results. The UV-Vis spectra changes showed that the azo dye sample, collected after 6 h irrad (mais) iation, was 98% decolorized while the residual total carbon was 97.9% degraded, indicating simultaneous photodecolorization and degradation.

Scientific Electronic Library Online (Portuguese)

29

Avaliação do coeficiente de atrito de braquetes metálicos e estéticos com fios de aço inoxidável e beta-titânio/ Evaluation of the friction coefficient of metal and esthetic brackets with stainless steel and beta-titanium wires

Braga, Cristine Pritsch; Vanzin, Guilherme Drumond; Marchioro, Ernani Menezes; Beck, João Carlos P.
2004-12-01

Resumo em português Um fator importante que define a eficácia dos aparelhos ortodônticos fixos é o atrito existente entre as superfícies de fios e braquetes. Assim, este estudo teve como objetivo investigar o coeficiente de atrito estático entre fios de aço inoxidável e beta-titânio (TP Orthodontics) e braquetes de aço inoxidável (Dynalock® - Unitek), braquetes estéticos com slot de aço inoxidável (Clarity® - Unitek) e estéticos convencionais (Allure® - GAC). Par (mais) a tanto, construiu-se um equipamento no Departamento de Engenharia Mecânica e Mecatrônica da PUCRS. Antes de serem iniciados os testes, foi quantificado o erro de método e constatou-se que não houve interferência significante (p>0,05) do fator operador nas medições. Então, pôde-se calcular o valor do coeficiente de atrito, obtido pela divisão da força de atrito pela carga normal. O método estatístico utilizado neste estudo foi Análise de Variância (ANOVA) e teste de Comparações Múltiplas (Tukey). Constatou-se que: 1) a combinação com menor coeficiente de atrito foi composta pelo fio de aço inoxidável e braquete Dynalock® e a que apresentou maior coeficiente foi a do braquete Allure® com o fio de beta-titânio; 2) o fio de beta-titânio apresentou coeficiente de atrito significativamente maior do que o fio de aço inoxidável; 3) o braquete Dynalock® não apresentou diferenças significativas em relação ao coeficiente de atrito do braquete Clarity® quando o fio utilizado foi de beta-titânio. No entanto, quando o fio testado foi de aço inoxidável, apresentou coeficiente de atrito significativamente menor. O braquete Clarity® apresentou coeficiente de atrito significativamente menor do que o braquete Allure®. Resumo em inglês An important factor that defines the effectiveness of the appliances is the friction between the surfaces of wires and brackets. Thus, that study was developed in order to investigate the static friction coefficient between stainless steel and beta-titanium wires (TP Orthodontics) and the stainless steel brackets (Dynalock® - Unitek), esthetic brackets with a stainless steel slot (Clarity® - Unitek) and conventional esthetic brackets (Allure® - GAC). For th (mais) is purpose, an equipment was built in the Department of Mechanical Engineering and Mechatronics at PUCRS. It should be stressed that before the tests began, the Method Error was quantified and it was found that there was no significant interference (p>0,05) by the factor operating in the measurements. From then, the friction coefficient could be calculated, obtained by dividing friction force by the normal load. The statistic method used in these study was Analysis of Variance (ANOVA) and Multiple Comparison test (Tukey). It was found that: 1) the combination with the lowest friction coefficient was constituted by the stainless steel wire against the Dynalock® bracket, and the one with the highest friction coefficient was that of the Allure® bracket with the beta-titanium wire; 2) the beta-titanium wire presented a friction coefficient that was significantly higher than the stainless steel wire; 3) the Dynalock® bracket did not present any significant differences in relation to the friction coefficient of the Clarity® bracket when the wire used was of beta-titanium. However, when the wire tested was of stainless steel, the Dynalock® bracket presented a significantly lower friction coefficient. The Clarity® bracket presented a significantly lower friction coefficient than the Allure® bracket.

Scientific Electronic Library Online (Portuguese)

30

Resistência à torção de dois instrumentos endodônticos rotatórios de níquel-titânio/ Torsional resistance of two nickel-titanium rotatory endodontic instruments

COSTA, Cristiane da; SANTOS, Marcelo dos
2000-06-01

Resumo em português Os autores compararam a resistência à torção entre os instrumentos rotatórios de níquel-titânio Quantec Series 2000 e Pow-R, valendo-se de quarenta instrumentos para cada marca divididos em oito para cada um dos seguintes tamanhos nº 15, nº 20, nº 25, nº 35 e nº 40 com 21 mm e conicidade .02. Com a ajuda de um troptômetro modificado cada instrumento foi fixado em um madril e preso à 3 mm de sua ponta, previamente marcada com uma caneta de tinta permanente, n (mais) a base do aparelho por uma morsa. Em seguida ativou-se a manivela que continha a escala em graus até notar-se sinal característico da fratura do instrumento registrando-se o valor da quantidade de movimento até este momento. Após tabulação dos dados procedeu-se a análise estatística de acordo com o teste t de Student com nível de significância de 1%. Os resultados mostraram haver diferença estatisticamente significante ao comparar-se limas de mesmo número confrontadas as duas marcas, favorável para o instrumento Pow-R. Resumo em inglês The authors compared the torsional resistance between the Quantec Series 2000 and Pow-R nickel-titanium rotatory instruments, using forty instruments of each brand, divided in eight of each one of the following numbers: nº 15, nº 20, nº 25, nº 35 and nº 40 with 21 mm and taper .02. Each instrument was fixed in the mandrel of a modified tropometer and held 3 mm away from its tip, on a spot that had been previously stamped with a permanent ink pen, by apprehension claw (mais) s localized on the base of the equipment. Then the graduated handle was activated until a characteristic break sign of the instrument was noticed, the quantity of movement up to this moment being recorded. After the values were tabulated, the statistical analysis was carried out according to the Student t test. The results revealed a statistically significant difference when instruments of the same number, from both evaluated brands, were compared, favouring the Pow-R instruments.

Scientific Electronic Library Online (Portuguese)

31

Estudo in situ do esmalte dental humano após aplicação de tetrafluoreto de titânio/ An in situ study of human enamel after titanium tetrafluoride application

MORAIS, Andréa Pereira de; SOUZA, Ivete Pomarico Ribeiro de; CHEVITARESE, Orlando
2000-06-01

Resumo em português O objetivo deste trabalho, cruzado, duplo-cego, realizado in situ, foi avaliar o esmalte dental humano submetido a um grande desafio cariogênico após aplicação de tetrafluoreto de titânio (TiF4) a 1%. Para isso, 5 voluntários utilizaram dispositivos intrabucais superiores contendo 80 fragmentos dentais durante 2 etapas (TiF4 e Controle) de 14 dias cada, gotejando 8 vezes ao dia glicose 25%. Após o uso, o esmalte foi submetido à análise através da MEV (microscopi (mais) a eletrônica de varredura) e a MDT (microdureza em corte transversal) em 5 posições até a profundidade de 100 µm da superfície anatômica do dente. Os resultados não revelaram diferença significativa entre esmalte decíduo e permanente. Os dados da MDT, submetidos à análise de variância multifatorial também não revelaram efeito significativo do TiF4, porém, através da MEV, verificou-se diferença entre TiF4 e Controle com p = 0,027 (teste do qui-quadrado). O número de lesões brandas era igual para os dois grupos, porém no Controle haviam 10 fragmentos com esmalte sem cárie e 18 com lesões severas contra 20 e 8 respectivamente do grupo TiF4. Os dados permitem sugerir que o TiF4 modificou o padrão da lesão formada amenizando-a, sendo necessários novos estudos definindo esse efeito em termos de profundidade. Resumo em inglês The purpose of this in situ, double blind, crossover study was to compare the effectiveness of an application of titanium tetrafluoride (TiF4) on deciduous and permanent enamel submitted to highly cariogenic conditions. Five volunteers used palatal appliances with 80 sections of teeth during two phases (TiF4 and Control) of 14 days each. They dropped 25% glucose on the sections, eight times per day. After that, the enamel was analyzed through scanning electron microscopy (mais) (SEM) and the Knoop Hardness Number (KHN) was determined at five different depths, up to 100 µm. The results revealed that differences between deciduous and permanent enamel were not significant. The KHN (Multiple Range Analysis) did not show a significant TiF4 effect, but SEM (Chi Square Test) results revealed differences between TiF4 and the Control group with p value = 0.027. There were equal numbers of incipient lesions in both groups, but there were 10 caries-free sections and 18 severe lesions in the Control group, against 20 and 8 in the TiF4 group, respectively. The findings suggested that lesions were less severe with TiF4 and that it changed the pattern of caries, but other studies are necessary to precisely define this effect, in terms of depth.

Scientific Electronic Library Online (Portuguese)

32

Efeitos de oxidantes e sais inorgânicos na degradação fotocatalítica do herbicida imazetapir mediada por dióxido de titânio/ Effects of oxidants and inorganic salts in the photocatalytic degradation of imazethapyr herbicide mediated by titanium dioxide

Yassumoto, L.; Osajima, J. A.; Takashima, K.
2007-01-01

Resumo em português A degradação fotocatalítica de imazetapir, um herbicida da família das imidazolinonas, em suspensão aquosa de dióxido titânio foi investigada na presença de dois receptores de elétrons como persulfato de potássio e periodato de sódio, assim como na presença de dois sais inorgânicos como sulfato de sódio e dihidrogenofosfato de sódio a 30ºC. O modelo cinético de pseudo-primeira ordem foi empregado para discutir os resultados. O desaparecimento de imazetapi (mais) r em função do tempo de irradiação foi analisado por cromatografia líquida de alta eficiência. Entre os dois oxidantes estudados a degradação foi mais rápida quando se adicionou o periodato de sódio, enquanto a presença do sulfato de sódio retarda a degradação de imazetapir mais que o dihidrogenofosfato na suspensão de TiO2. Resumo em inglês Photocatalytic degradation of imazethapyr, an imidazolinone family herbicide, was investigated in titanium dioxide aqueous suspension in the presence of electron acceptors such as potassium persulfate and sodium periodate, as well as in the presence of two inorganic salts such as sodium sulfate and sodium dihydrogen phosphate at 30ºC. A pseudo-first order kinetic model was used to discuss the results. The imazethapyr disappearance as a function of the radiation time was (mais) analyzed by high performance liquid chromatography. In comparison between two oxidants, the degradation was faster in the presence of periodate, meanwhile in the presence of the inorganic salt sodium sulfate retarded the oxidation more than dihydrogen phosphate ions in the TiO2 suspension.

Scientific Electronic Library Online (Portuguese)

33

Sinterização de pastilhas de nitreto cúbico de boro utilizando como ligantes compostos de titânio/ Sintering of cubic boron nitride inserts using titanium-based binders

Valpassos, J.M.; Ramalho, A.M.; Bobrovnitchii, G.S.; Monteiro, S.N.
2007-01-01

Resumo em português O Nitreto Cúbico de Boro (cBN) é uma forma alotrópica sintética do nitreto de boro que é obtida sob condições de altas pressões e altas temperaturas (HPHT), geralmente a partir do nitreto hexagonal de boro (hBN). Compactos sinterizados de cBN são produzidos sinterizando cBN e ligantes na faixa de 6,0-8,0GPa e cerca de l600-2000°C em tempos que variam até 30 minutos. No presente trabalho, compósitos de cBN com ligantes a base de titânio em l0%p foram sinteriza (mais) dos em parâmetros de 7,7GPa e 2000K. Análises por MEV apresentaram uma estrutura parcialmente sinterizada. A dureza e resistência ao desgaste foram estudadas demonstrando resultados promissores. As propriedades mecânicas dos compósitos foram avaliadas em situações reais de trabalho, por meio de usinagem do aço AISI 4140 endurecido a 54-HRC. Resumo em inglês Cubic boron nitride (cBN) is a synthetic allotropic form of boron nitride that is obtained under high pressure and high temperature (HPHT) conditions, usually from hexagonal boron nitride (hBN). Cubic boron nitride compacts are produced by sintering cBN with binder into HPHT conditions at range of 6,0-8,0GPa and temperature between 1600-2000°C during up to 30 minutes. In the present work, composites of cBN with titanium-based binders with cBN ratio of 90%w were sintered (mais) under HPHT conditions, 7,7GPa and 2000K. SEM analysis observations showed some porous, as sash, the structure was partially sintered. Hardness and wear resistance were carried through demonstrating good results. The mechanical investigations were performed using a turning machine and a AISI 4140 hardened steel cylinder with 54HRC, in real work conditions without cooling.

Scientific Electronic Library Online (Portuguese)

34

Fatores que influenciam na atividade de titanocenos em catálise homogênea de polimerização de estireno/ Factors of influence in the activity of titanocenes in the homogeneous catalysis of polymerization of polystyrene

PEREIRA, Brasílio Carvalho de Araújo; KLEIN, Stanlei Ivair
2000-01-01

Resumo em português É apresentada uma revisão bibliográfica com 42 referências abordando aspectos históricos dos compostos organometálicos de titânio, sua aplicação em sistemas catalíticos utilizando metalocenos de titânio e os fatores que influenciam a catálise de alfa-olefinas com as conseqüentes repercussões nas estruturas dos polímeros. Resumo em inglês It is presented a review with 42 references dealing with the historical aspects of organometallics of titanium, the application of titanocenes in catalytical systems and the factors that may be of influence in the polymerisation of alpha-olefinas with the consequent repercussions on the structures of the polymers.

Scientific Electronic Library Online (Portuguese)

35

Caracterização estrutural da cerâmica Ti x(Sm0,2Ce0,8)1-xO 2-delta pelo método de Rietveld/ Structural study of Ti x(Sm0.2Ce0.8 )1-xO2-delta ceramic by the Rietveld method

Domingues, S.; Pereira, T. J.; Florentino, A. O.; Cavalheiro, A. A.; Saeki, M. J.
2007-06-01

Resumo em português O método precursor polimérico foi aplicado para a síntese de pós de Ti x(Sm0,2Ce0,8)1 xO2-delta, com 0 (mais) traram monofásicas como cerianita. Para as amostras tratadas a 1000 ºC, a deformação provocada pela introdução do titânio é suprimida e a solubilidade do titânio na cerianita se limita a valores de x Resumo em inglês Powders of Ti x(Sm0.2Ce0.8)1-xO 2-delta, 0 (mais) gle phase, cerianite. In the samples treated at 1000 ºC the lattice deformation was suppressed segregating titanium as samarium titanate and rutile, depending on x. The solubility of titanium is limited to x 0.20) the rutile phase precipitates. At the same time the samarium titanate content decreases and samarium migrates into the cerianite phase. These phenomena can be proved by the increase in lattice parameters.

Scientific Electronic Library Online (Portuguese)

36

Composição química e aspecto superficial do slot de braquetes metálicos/ Elemental composition and superficial aspect of metallic brackets slot

Assad-Loss, Tatiana Féres; Neves, Regina Maria Lopes; Mucha, José Nelson
2008-06-01

Resumo em português OBJETIVO: avaliar a composição química e rugosidade do fundo do slot de 90 braquetes metálicos divididos em 9 grupos: grupo 1- aço inoxidável (Equilibrium 2 - Dentaurum); grupo 2 - titânio (Equilibrium ti - Dentaurum); grupo 3- cromo-cobalto (Topic- Dentaurum); grupo 4 - aço inoxidável (Standard -TP Orthodontics); grupo 5 - aço inoxidável (Serie light - American Orthodontics); grupo 6 - aço inoxidável (Kirium Line - Abzil Lancer); grupo 7 - aço inoxidável l (mais) ivre de níquel (Monobloc - Morelli); grupo 8 - aço inoxidável (Convencional- Morelli) e grupo 9 - aço inoxidável livre de níquel (Monobloc Golden - Morelli). METODOLOGIA: a composição química foi analisada pela Espectroscopia de Energia Dispersiva. A avaliação qualitativa do fundo do slot foi realizada através do MEV classificada de 0 a 8, correspondente às características da superfície. RESULTADOS: composição química - grupo 1 = titânio puro; grupo 9 = recoberto por nitreto de titânio em 99,48%; grupo 3 = cromo-cobalto; grupo 8 = aço inoxidável livre de níquel. Os demais grupos são compostos de aço inoxidável. Avaliação da superfície - grupo 1 = valor 2 (superfície mais polida); grupos 2, 5 e 7 = valor 3 (aspecto de polimento); grupos 3, 8 e 9 = valor 6 (menor polimento); grupo 4 = valor 6,5 (maior rugosidade) e o grupo 6 = valor 5 (características intermediárias de polimento). CONCLUSÕES: os braquetes metálicos são compostos de diferentes ligas e estão disponíveis com baixo conteúdo ou ausência de níquel. Os braquetes de titânio apresentaram polimento semelhante aos de aço inoxidável, porém os recobertos por nitreto de titânio e os de cromo-cobalto mostraram superfície mais irregular ou menos polida. Resumo em inglês AIM: To evaluate the elemental composition and the slot roughness of 90 metallic brackets divided into 9 groups: group 1 - stainless steel (Equilibrium 2 - Dentaurum); group 2 - titanium (Equilibrium ti - Dentaurum); group 3 - chromium-cobalt (Topic - Dentaurum); group 4 - stainless steel (Standard - TP Orthodontics); group 5 - stainless steel (Serie light - American Orthodontics); group 6 - stainless steel (Kirium Line - Abzil Lancer); group 7 - stainless steel (Monobloc (mais) - Morelli); group 8 - stainless steel (Standard - Morelli) and group 9 - stainless steel (Monobloc Golden - Morelli). METHODS: Elemental composition was evaluated using the Spectroscopy of Dispersive Energy. The qualitative slot surface evaluation was assessed using a 500X scanning electron microscope. The microphotography was classified according to surface characteristics in 0-8 values. RESULTS: Elemental composition - group 1 = 100% titanium alloy; group 9 = 99,48% of titanium nitride coated. Group 3 = cobalt-chromium alloy; Group 8 = nickel free stainless steel alloy; other groups stainless steel alloy. Surface evaluation - Group 1 = value 2 (smoothest surface); Groups 2, 5 and 7 =value 3 (smooth surface); Groups 3, 8 and 9 showed value 6 (roughness surface); Group 4 = value 6,5 (the most roughness and irregular surface); and Group 6 has intermediate characteristics among the groups, with value 5. CONCLUSIONS: Metallic brackets were composed of different alloys and they were available with a small percentage or no nickel. The surface roughness was similar for both titanium and stainless steel, however the titanium nitride coated and cobalt-chromium showed an irregular and rough surface.

Scientific Electronic Library Online (Portuguese)

37

Análise da resistência de fios cirúrgicos utilizados no reparo do manguito rotador/ Strength analysis of surgical sutures used to repair the rotator cuff

Guimarães, Marcus Valladares; Carvalho Júnior, Lúcio Honório de
2008-07-01

Resumo em português OBJETIVO: Analisar a resistência final suportada por dois tipos de fio e pela interface âncora-fio em três diferentes implantes tipo âncora submetidos à tração contínua, com o propósito de indicar o mais apropriado para sutura de estruturas como o manguito rotador do ombro. MÉTODOS: Os testes foram feitos em três grupos: grupo 1 - parafuso âncora de titânio com fio Ethibond® #2; grupo 2 - parafuso âncora de titânio com fio Fiber Wire® #2; e grupo 3 - para (mais) fuso âncora de titânio 5,0mm Corkscrew®. RESULTADOS: No grupo 1, a carga máxima média até a soltura foi de 124,5 newtons (N), sendo a mínima de 105N e a máxima de 180N, com variação de 75N entre os dois extremos e desvio-padrão de 23,03N. No grupo 2, a carga máxima média até a soltura foi de 298N, mínima de 230N, máxima de 375N, com variação de 145N e desvio-padrão de 44,73N. No grupo 3, foi obtida a maior carga máxima média, sendo esta de 272N, a mínima de 205N e a máxima de 340N, com variação de 135N. A análise estatística demonstrou diferença significativa entre as médias de cargas resistidas entre os grupos 1 x 2 e 1 x 3 (p Resumo em inglês OBJECTIVE: To analyze the final strength withstood by two types of suture threads and by the anchor-suture interface in three different anchor implants submitted to continuous traction for the purpose of choosing the most appropriate to suture structures such as the shoulder rotator cuff. METHOD: Tests were performed in three groups: Group 1 - titanium anchor screw with Ethibond® #2 suture, Group 2 - titanium anchor screw with Fiber Wire® #2 suture, and Group 3 - Corksc (mais) rew® 5.0 mm anchor screw. RESULTS: In Group 1, mean maximum load till loosening was 124.5 124,5 Newtons (N), the minimum load was 105 N, and the maximum load was 180 N, with a range of 75 N between the two extremes, and standard deviation of 23.03 N. In Group 2, the mean maximum load till loosening was 298 N, the minimum load was 230 N, the maximum load was 375 N, with a range of 145 N, and standard deviation of 44.73 N. In Group 3, the highest mean maximum load was measured, of 272 N, the minimum load was 205 N, and the maximum load of 340 N, with a range of 135 N. Statistical analysis showed a significant difference between the mean loads withstood between groups 1 and 2, and between groups 1 and 3, (p

Scientific Electronic Library Online (Portuguese)

38

Avaliação de indicadores em estudos com ruminantes: estimativa de consumos de concentrado e de silagem de milho por vacas em lactação/ Prediction of individual dry matter intake in group-fed lactating dairy cows

Ferreira, Marcelo de Andrade; Valadares Filho, Sebastião de Campos; Silva, Luiz Fernando Costa e; Nascimento, Fernando Barros; Detmann, Edenio; Valadares, Rilene Ferreira Diniz
2009-08-01

Resumo em português Dois trabalhos foram conduzidos para estimativa do consumo individual de vacas em lactação alimentadas em grupo. No primeiro, para validar a metodologia, foram utilizadas oito vacas, alojadas em baias individuais recebendo silagem de milho e 4 kg de concentrado. Dois indicadores externos (óxido crômico e dióxido de titânio) foram avaliados para estimativa do consumo individual de concentrado. A fibra em detergente ácido indigestível (FDAi) foi utilizada para estim (mais) ativa do consumo de silagem. A produção de matéria seca fecal (PMSF) foi determinada pela coleta total de fezes e estimada pelo LIPE®. Tanto o óxido crômico quanto o dióxido de titânio permitiram estimar com eficiência o consumo de concentrado, independentemente do método para estimativa da PMSF. A FDAi estimou de forma satisfatória o consumo de silagem de milho. No segundo experimento, foram utilizadas 31 vacas, distribuídas em três grupos de alimentação, alojadas em estábulo tipo free stall e alimentadas com silagem de milho e concentrado de acordo com a produção de leite (8,0; 5,5 e 4 kg, para os grupos 1, 2 e 3, respectivamente). Não houve diferença entre o óxido crômico e o dióxido de titânio no consumo de MS do concentrado, que foi muito próximo da quantidade média fornecida por vaca/dia (6,99 vs 7,12; 4,81 vs 4,96 e 3,49 vs 3,52 kg/vaca/dia). Verificou-se grande variação individual no consumo de concentrado, silagem e matéria seca total, independentemente do grupo de alimentação. Não foi verificada relação entre o consumo de matéria seca, a produção de leite e o peso metabólico dos animais. O óxido crômico e o dióxido de titânio podem ser usados para estimativa do consumo individual de concentrado e a FDAi é adequada para estimativa do consumo de silagem de milho por vacas em lactação alimentadas em grupo. Resumo em inglês Two studies were carried out to evaluate individual dry matter intake of group-fed lactating dairy cows. In the first trial, eight cows were housed in individual pens and fed corn silage and 4 kg of concentrate meal. Two external markers (chromium oxide and titanium dioxide) were used to predict individual concentrate intake. Indigestible acid detergent fiber (iADF) was used to estimate individual silage intake. Fecal dry matter output (FDMO) was determined by total colle (mais) ction and also by LIPE®. Chromium oxide and titanium dioxide were able to estimate individual concentrate intake, regardless of the FDMO method. The iADF marker was able to estimate the individual silage intake. In the second trial, 31 cows were distributed in three groups, housed in a free stall and fed corn silage and concentrate according to milk yield (8.0, 5.5, and 4 kg, for groups 1, 2 and 3, respectively). There was no difference between chromium oxide and titanium dioxide in the estimates of individual concentrate intake which were similar to the observed values (7.12 vs 6.99, 4.96 vs 4.81 and 3.52 vs 3.49 kg/cow/day). Individual intakes of concentrate, silage and total dry matter varied considerably, regardless of the group. There was no relationship among dry matter intake, milk yield and metabolic body weight. Chromium oxide and titanium dioxide and iADF can be used to estimate individual intakes of concentrate and corn silage, respectively, by group-fed lactating dairy cows.

Scientific Electronic Library Online (Portuguese)

39

Estudo laboratorial do tempo de fechamento das alças e do grau de inclinação do canino, durante o procedimento de retração, empregando mecânica de arco segmentado/ Laboratorial study of loops closure time and degree of cuspid´s tipping, during the retraction phase, using segmented arch mechanics

Bisol, Gilberto Kauling; Rocha, Roberto
2010-02-01

Resumo em português OBJETIVO: avaliar o tempo de retração e o grau da inclinação sofrida pelo canino empregando três tipos de molas ortodônticas para retração - a alça em "T", a alça em "L" e a alça em forma de gota. MÉTODOS: foram utilizados três tipos de fio - aço inoxidável da marca comercial Morelli, aço inoxidável da marca comercial 3M Unitek e liga de beta-titânio da marca comercial Ormco; todos de calibre 0,019" x 0,025". A amostra resultante da combinação dos fato (mais) res mola e fio foi submetida à avaliação em modelo de typodont específico para essa finalidade. RESULTADOS: com relação ao tempo de fechamento das alças, verificou-se que um fechamento mais lento, e consequentemente com menor liberação de forças, foi obtido com o desenho de alça em "T" e, ainda, empregando-se a liga de beta-titânio para sua confecção. No que diz respeito à inclinação gerada pelas alças, as alças em forma de gota promoveram uma inclinação dentária maior do que as demais avaliadas. As alças em "T", por outro lado, mantiveram-se relacionadas estatisticamente aos menores valores de inclinação. Porém, quando se empregou o fio de aço inoxidável da marca comercial 3M Unitek para sua confecção, os três tipos de alça não apresentaram diferença estatisticamente significante. CONCLUSÃO: independentemente do desenho de alça empregado, aquelas construídas com liga de beta-titânio mantiveram-se relacionadas estatisticamente aos menores valores de inclinação observados para o elemento dentário movimentado. Resumo em inglês OBJETIVE: Evaluate the cuspid's retraction time and tipping effects, after submitting it to three different orthodontic retraction loops: the "T" loop, the "boot" loop, and the "tear drop" loop. METHODS: It was used the following orthodontic wires: Morelli 0.019" x 0.025" stainless steel, 3M Unitek 0.019" x 0.025" stainless steel and Ormco 0.019" x 0.025" beta-titanium (TMA™). The resulting sample from the combination of these variables was submitted to a test devel (mais) oped on a typodont simulator used specifically for this purpose. RESULTS: As the closure timing concerns, it was verified that a slower closure and therefore, a smaller releasing force system was achieved by the "T" loop design and still, by employing the beta-titanium alloy on its construction. As to the tipping effects generated by the retraction device, the "tear drop" loop caused greater tipping effects than the other loops evaluated. The "T" loop, on the other hand, showed itself statistically related to the lowest tipping numerical values. However, when the 3M Unitek stainless steel wire was used to produce the device, all of the types of loops evaluated were considered statistically similar. CONCLUSION: Regardless of the loop design, the ones built out of beta-titanium alloy kept them statistically related to the lowest tipping numerical values observed for the retracted dental element.

Scientific Electronic Library Online (Portuguese)

40

Espectroscopia anelástica em ligas de Nb-16% p. Ti

Nogueira, Renata Abdallah; Niemeyer, Terlize Cristina; Grandini, Carlos Roberto; Florêncio, Odila
2003-12-01

Resumo em português Átomos de oxigênio, presentes em metais com estrutura cristalina cúbica de corpo centrado, são localizados preferencialmente em sítios octaedrais. Na ausência de uma tensão mecânica externa, estes átomos são distribuídos aleatoriamente. Na presença de oscilações mecânicas, a redistribuição dos átomos nos diferentes sítios deve ocorrer pela interação com esta tensão, levando a perdas na energia elástica. Este trabalho mostra o estudo da interação d (mais) e átomos de oxigênio presentes em amostras da liga Nb-16% p. Ti, utilizando um pêndulo de torção. Os resultados mostram espectros bastante complexos, que foram decompostos em seus picos constituintes, representando os processos de relaxação devido à reorientação induzida por tensão de átomos e pares de átomos de oxigênio em torno de átomos de nióbio da matriz metálica e átomos de oxigênio em torno de átomos de titânio (interação substitucional-intersticial).

Scientific Electronic Library Online (Portuguese)

41

Avaliação de indicadores em estudos com ruminantes: digestibilidade/ Evaluation of markers in ruminant trials: digestibility

Ferreira, Marcelo de Andrade; Valadares Filho, Sebastião de Campos; Marcondes, Marcos Inácio; Paixão, Mônica Lopes; Paulino, Mário Fonseca; Valadares, Rilene Ferreira Diniz
2009-08-01

Resumo em português Foram conduzidos dois experimentos com o objetivo de avaliar os indicadores internos fibra em detergente neutro indigestível (FDNi) e fibra em detergente ácido (FDAi), obtidos por incubação in situ durante seis dias, e os indicadores externos óxido crômico (Cr2O3), dióxido de titânio (TiO2) e lignina isolada, purificada e enriquecida (LIPE®) em dois esquemas de coleta total de fezes (3 ou 5 dias) para estimativa da digestibilidade em bovinos. O delineamento exper (mais) imental foi o de blocos ao acaso com parcelas subdivididas. No primeiro experimento, foram utilizadas cinco novilhas mestiças alimentadas com cana-de-açúcar com 1% de ureia/sulfato de amônio e concentrado (1% do peso vivo). Não houve diferenças entre as metodologias de coleta para a digestibilidade da matéria seca. Quando estimada utilizando-se FDAi, a digestibilidade dos nutrientes foi subestimada, mas, quando estimada utilizando-se FDNi e os indicadores externos (óxido crômico, dióxido de titânio e LIPE®), não diferiu significativamente daquela determinada por coleta total de fezes. No segundo experimento, foram utilizadas oito vacas em lactação alimentadas com silagem de milho e 4 kg de concentrado. Não houve diferença na digestibilidade da matéria seca entre os períodos de coleta. A digestibilidade dos nutrientes, quando estimada utilizando-se FDNi, foi superestimada, mas, quando estimada utilizando-se FDAi e os indicadores externos (óxido crômico, dióxido de titânio e LIPE®), não diferiu significativamente daquela determinada por coleta total de fezes. Três dias de coleta são suficientes para estimativa da digestibilidade e os indicadores testados são eficientes na determinação da digestibilidade. Resumo em inglês Two studies were carried out to evaluate indigestible neutral detergent fiber (iNDF) and indigestible acid detergent fiber (iADF) as internal markers obtained by 144-h incubation in situ and chromium oxide (Cr2O3), titanium dioxide (TiO2) and isolated, purified and enriched lignin (LIPE®) as external markers, and two total fecal collection schemes (3 or 5 days) to estimate digestibility in bovines. The experimental procedure was a randomized block design in a split plot (mais) arrangement. In the first trial, five crossbreed heifers fed sugar cane plus 1% of urea/ammonium sulfate and concentrate (1% of body weight) were used. There was no difference for dry matter digestibility when the collection schemes were compared (5 days vs 3 days). The nutrient digestibility estimated by iADF was underestimated and those estimated by iNDF, chromium oxide, titanium dioxide and LIPE®, did not differ from the digestibility calculated on total fecal collection. In the second trial, eight lactating cows fed corn silage and concentrate (4 kg/cow/day) were used. There was no difference for dry matter digestibility when the collection schemes were compared (5 days vs 3 days). The nutrient digestibility estimated by iNDF was overestimated and those estimated by iADF, chromium oxide, titanium dioxide and LIPE®, did not differ from the digestibility calculated on total fecal collection. Three days of fecal collection and the markers tested can safely be used to estimate digestibility.

Scientific Electronic Library Online (Portuguese)

42

Mobilidade de cátions em alteração intempérica de diabásio no município de Rio das Pedras, SP/ Cation mobility in weathering alteration op diabase in Rio das Pedras-SP county

Marconis, A.
1991-01-01

Resumo em português Em uma sequência de alteração intempérica de diabásio, é estudada a mobilidade dos principais cátions, desde a rocha não alterada até o solo de origem. Da rocha primitiva, apenas cerca de 44% de material sólido permanecem na fase final, constituindo a fração detrítica do solo. A eliminação dos cátions solúveis é rápida e ocorre nas primeiras fases da alteração. A sílica, removida mais lentamente, tem cerca de 60% eliminada, permanecendo no solo o alumínio, o ferro e parcialmente o titânio. Resumo em inglês The mobility of the principal cations of a diabase is studied in a weathering sequence, from unaltered rock to the rock-derived soil. From the original rock, just about 44% of the original rock material remains in the final fase, making up the detrital fraction of the soil. Elimination of the soluble cations is fast and occurs in the early weathering stages. Silica, which is removed at a slower rate is eliminated up to about 60% of the original rock content, while aluminium, iron and titanium stay in the soil.

Scientific Electronic Library Online (Portuguese)

43

Liberação in vivo de íons metálicos por mini-implantes ortodônticos de Ti-6Al-4V/ In vivo metal ion release from Ti-6Al-4V orthodontic mini-implants

Morais, Liliane S; Serra, Glaucio G; Muller, Carlos A; Palermo, Elisabete F A; Andrade, Leonardo R; Meyers, Marc A; Elias, Carlos N
2007-01-01

Resumo em português Mini-implantes ortodônticos de Ti-6Al-4V podem liberar íons metálicos devido à corrosão in vivo da liga em fluidos corporais. Os produtos de corrosão liberados podem favorecer a ocorrência de efeitos indesejáveis no corpo humano. O objetivo deste estudo foi determinar as concentrações de titânio, alumínio e vanádio nos órgãos de coelhos (rins, fígado e pulmões), após a inserção de mini-implantes ortodônticos fabricados a partir da liga Ti-6Al-4V. Dezo (mais) ito coelhos da raça Nova Zelândia tiveram quatro mini-implantes inseridos em sua tíbia esquerda e cinco coelhos foram usados como controle. Após 1, 4 e 12 semanas os coelhos foram submetidos à eutanásia, os tecidos selecionados foram removidos e preparados para análise por espectroscopia de absorção atômica com forno de grafite. Quantidades variadas Ti, Al e V foram detectadas nos grupos testados comprovando que existe liberação de íons metálicos por mini-implantes ortodônticos de Ti-6Al-4V. Apesar da tendência de liberação de íons pela liga de titânio, as quantidades de metais detectadas foram extremamente baixas. Sendo assim, mini-implantes ortodônticos de Ti-6Al-4V podem ser usados com segurança como dispositivos auxiliares de ancoragem ortodôntica. Resumo em inglês Ti-6Al-4V orthodontic mini-implants may release metallic ions to the human body due to the in vivo corrosion of the alloy in body fluids. The corrosion products can elicit undesirable effects in the human body. The purpose of this study was to measure the concentration of titanium, aluminum, and vanadium in rabbits’ tissues (kidney, liver and lungs) after the insertion of Ti-6Al-4V alloy orthodontic mini-implants. Eighteen New Zealand rabbits had four mini-implants inser (mais) ted in their left tibia and five rabbits were used as control. After 1, 4, and 12 weeks the rabbits were euthanized, the selected tissues were extracted, and prepared to analysis by graphite furnace atomic absorption spectrometry. Varied amounts of Ti, Al, and V were detected in the tested groups proving that diffusion of these metals from Ti-6Al-4V orthodontic mini-implants exists. Despite of the tendency of ion release when using the titanium alloy, the amount of metals detected were very low. Then, Ti-6Al-4V orthodontic mini-implants are safe auxiliary orthodontic anchorage devices.

Scientific Electronic Library Online (Portuguese)

44

Níveis de inclusão e tempo de exposição da cana-de-açúcar ao óxido de cálcio sobre parâmetros digestivos e o desempenho de novilhas Nelore/ Levels of inclusion and exposure time of sugar cane to calcium oxide on digestive parameters and performance of Nellore heifers

Pina, Douglas dos Santos; Valadares Filho, Sebastião de Campos; Tedeschi, Luis Orlindo; Barbosa, Analívia Martins; Azevêdo, José Augusto Gomes; Valadares, Rilene Ferreira Diniz; Souza, Natália Krish de Paiva; Fonseca, Mozart Alves
2011-03-01

Resumo em português Avaliou-se nesta pesquisa o efeito da inclusão de óxido de cálcio (cal) e dos tempos de exposição da cana-de-açúcar à cal sobre o desempenho de novilhas Nelore, a digestibilidade dos componentes da dieta e a síntese de proteína microbiana ruminal (PBMic) e comparou-se o dióxido de titânio ao óxido crômico para estimar o consumo individual de concentrado. Utilizaram-se 30 fêmeas Nelore com aproximadamente 24 meses de idade e pesos médios de 285 ± 31 kg, al (mais) ojadas em seis baias coletivas. As dietas foram arranjadas em esquema fatorial 3 × 2, com três níveis de cal (0; 0,5 ou 1% na matéria natural) e dois tempos de exposição (zero e três dias). Os tempos de exposição da cana-de-açúcar à cal não tiveram efeitos sobre as quantidades de nitrogênio microbiano, os consumos de matéria seca (MS) e orgânica (MO), proteína bruta (PB), total de nutrientes digestíveis e o ganho médio diário, porém influenciaram os consumos de extrato etéreo (EE), fibra em detergente neutro corrigida para cinzas e PB (FDNcp) e carboidratos não-fibrosos (CNF). Os níveis de cal influenciaram de forma linear decrescente os consumos de MO, FDNcp, CNF e NDT, e o GMD. Todavia, não foram observados efeitos dos indicadores (dióxido de titânio e óxido crômico) nem interações do tempo de exposição e do nível de cal sobre os consumos de MS, MO, PB, EE, FDNcp, CNF e NDT. Interações significativas do tempo de exposição e do nível de inclusão de cal foram observadas para as digestibilidades aparentes totais da MS, MO, PB e FDN e para o teor de NDT. Os indicadores dióxido de titânio e óxido crômico são igualmente efetivos para estimar os consumos individuais de concentrado de bovinos alimentados em grupo. O fornecimento de cana-de-açúcar armazenada durante três dias sem cal não altera o desempenho de novilhas em crescimento. Resumo em inglês It was evaluated in this work the effects of levels of inclusion and exposure times of sugarcane to calcium oxide on the performance of Nellore heifers, digestibility of dietary components and synthesis of ruminal microbial protein and it was compared titanium dioxide to chromium oxide to estimate the individual intake of concentrate. It was used 30 Nellore females at approximately 24 months of age and average body weight of 285 ± 31 kg and age of 24 months housed in six (mais) pens (50 m² approximately), each one of them with five animals (feeding group). The diets were allocated in a 3 × 2 factorial arrangement, containing three levels of calcium oxide (0; 0.5 and 1.0% of sugarcane fresh matter) and two levels of exposure time (0 and 3 days). There were no effects of calcium oxide exposure time on the intake of microbial nitrogen, dry matter (DM), organic matter (OM), crude protein (CP) and total digestible nutrients (TDN) and daily weight gain, but, it affected the intake of ether extract (EE), neutral detergent fiber corrected for ash and CP contamination (NDFcp), and nonfiber carbohydrate (NFC). The levels of whitewash decreased linearly the intake of OM, NDFap, NFC, and ADG. However, it was not observed effects of the markers (titanium dioxide and chromic oxide) nor interactions among exposure time and level of whitewash on intakes of DM, CP, EE, NDFap, NFC and TDN. Significant interactions between exposure time and level of inclusion of whitewash were observed for total aparent digestibility of DM, OM, and NDF and for content of TDN. Titanium oxide and chromic oxide are equally effective for estimating individual intakes of concentrate by bovine fed in group. Supply of sugar cane stored for three days without whitewash does not change performance of growing heifers.

Scientific Electronic Library Online (Portuguese)

45

Mini-implantes ortodônticos carregados imediatamente: estudo in vivo/ Orthodontic mini-implants immediately loaded: in vivo study

Serra, Glaucio G; Morais, Liliane S; Elias, Carlos N; Andrade, Leonardo; Muller, Carlos Alberto
2007-01-01

Resumo em português Mini-implantes têm sido utilizados com sucesso como elemento de ancoragem ortodôntica, mas a diminuição do tamanho e a aplicação precoce da carga são requisitos importantes para a otimização da metodologia. A proposta deste trabalho foi avaliar a evolução da fixação óssea de mini-implantes de titânio carregados imediatamente. Nove coelhos da raça Nova Zelândia foram utilizados neste estudo. Em cada animal foram inseridos 4 mini-implantes de titânio grau (mais) 5 (liga Ti-6Al-4V) , dos quais 2 foram carregados imediatamente com 1 N. Os animais foram eutanasiados após 1, 4 e 12 semanas e as amostras foram divididas em seis grupos, sendo 3 grupos carregados e 3 grupos sem carga. O ensaio de torque de remoção dos implantes foi realizado e os resultados tratados estatisticamente com o módulo ANOVA e pós-teste de Tukey. Após 1 e 4 semanas de cicatrização não foi detectada diferença estatisticamente significativa nos valores de torque de remoção, independente do carregamento. Entretanto, após 12 semanas, tanto o grupo carregado quanto o não carregado apresentaram aumento significativo no torque de remoção e os maiores valores foram atribuídos ao grupo sem carregamento. O carregamento imediato resultou em menor fixação óssea dos mini-implantes após 12 semanas de cicatrização, contudo não comprometeu a estabilidade dos implantes. Resumo em inglês The mini-implants have been successfully used as orthodontic bone anchorage, but the size reduction and the early load are required to improve the methodology. The purpose of this work was to evaluate the bone fixation evolution of the immediately loaded titanium grade 5 (Ti-6Al-4V alloy) mini-implants. Nine New Zealand rabbits were used in this study. Each rabbit had four mini-implants inserted in his left tibia and the two of them were immediately loaded with 1 N. The a (mais) nimals were euthanized after 1, 4 and 12 weeks and the sample were divided in six groups, in which three groups were loaded and the other three were unloaded. The removal torque test was done and the results were statistically analyzed by ANOVA and post hoc test Tukey. There were no statistically significant differences in the removal torque values after 1 and 4 weeks of healing, regardless the loading. Nevertheless, both unloaded and loaded group presented higher removal torque values after 12 weeks of healing and the unloaded group had the highest result. The immediate loading resulted in lower bone fixation of the mini-implants after 12 weeks of healing, although did not compromise the mini-implants’ stability.

Scientific Electronic Library Online (Portuguese)

46

Fotocatálise heterogênea com TiO2 aplicada ao tratamento de esgoto sanitário secundário/ TiO2 heterogeneous photocatalysis in secondary wastewater treatment

Ferreira, Ivete Vasconcelos Lopes; Daniel, Luiz Antonio
2004-12-01

Resumo em português Neste trabalho são apresentados resultados da aplicação da fotocatálise heterogênea utilizando dióxido de titânio imobilizado sobre placa de vidro, irradiado por luz solar, para desinfecção de esgoto sanitário secundário. Utilizou-se o efluente de um reator anaeróbio/aeróbio com leito expandido de carvão ativado que trata o esgoto do Campus da USP/São Carlos, e também de contribuições domésticas. Os experimentos foram do tipo batelada, com tempo de reci (mais) rculação de 4 horas. As vazões estudadas foram 15, 22,5 e 30 L/h. Foram avaliadas as remoções de matéria orgânica (DQO e COT) e a inativação de microrganismos indicadores de contaminação fecal (coliformes totais, E. coli, Clostridium perfringens e colifagos). Resumo em inglês The results of wastewater anaerobic-aerobic reactor effluent disinfected with heterogeneous photocatalysis using titanium dioxide fixed in a glass plate and solar radiation are presented in this work. The anaerobic-aerobic reactor has a granular activated carbon expanded bed and it receives the wastewater collected in the Campus of São Paulo University at São Carlos-SP, Brazil, and from the surrounding neighborhood of the campus. The assays were conducted in batch with (mais) recirculation time of 4 hours. The flow rate used was of 15, 22.5 and 30 L/h. The removal of organic matter (COD and TOC) and inactivation of total coliforms, E. coli, Clostridium perfringens and coliphages was evaluated.

Scientific Electronic Library Online (Portuguese)

47

Estudo da influência da microestrutura do clínquer sobre a moagem na fabricação de cimento: microscopia eletrônica de varredura

Souza, Vládia Cristina Gonçalves; Sampaio, Carlos Hoffmann; Tavares, Luis Marcelo Marques
2002-09-01

Resumo em português Como continuação de um estudo anteriormente realizado com microscopio óptico (MO) e lupa, sobre amostras de clínquer coletadas em uma fábrica de cimento no sul do Brasil, foram realizadas análises em microscópio eletrônico de varredura (MEV). O objetivo foi buscar mais informações que pudessem ou não corroborar o resultado de alto grau de corrosão dos cristais, apontado pelos primeiros instrumentos, devido à presença de um alto conteúdo de metais. As análi (mais) ses em MEV mostraram a existência de um padrão de microfissuras e de corrosão dos cristais, tanto de alita quanto de belita. O uso do EDS ou EDX (energy dispersive X-ray) ajudou a fortalecer a hipótese de uma situação de alto conteúdo de Fe2O3 e fase líquida e de metais, inclusive titânio. Resumo em inglês As continuation of a study previously realized with optical microscope and magnifying glass, on samples of clinker collected from a factory at south of Brazil, it was realized analysis on electron microscopic. The objective was search more information that could or not corroborate the high degree of corrosion of the crystals result, pointing by first instruments, due the presence of a high content of metals. The analysis on electron microscope have show the existence of a (mais) model of microcracks and of corrosion of the crystals, as much alite as belite. The use of the energy dispersive X-ray help to fortify the hypothesis of a situation with high content of Fe2O3, liquid phase and metals, included titanium.

Scientific Electronic Library Online (Portuguese)

48

Ovário-histerectomia laparoscópica em felinos hígidos: estudo comparativo de três métodos de hemostasia/ Laparoscopic ovariohysterectomy in healthy felines: comparative study of three hemostatic methods

Schiochet, F.; Beck, C.A.C.; Silva, A.P.F.F.; Contesini, E.A.; Alievi, M.M.; Stedile, R.; Pinto, V.; Yamazaki, P.H.; Jurinitz, D.F.; Pellizari, M.
2009-04-01

Resumo em português Foram avaliadas 24 gatas, hígidas, sem raça definida, distribuídas em três grupos de oito animais. Descreveu-se o acesso laparoscópico para ovariossalpingo-histerectomia (OSH) e comparou-se o uso do eletrocautério bipolar (grupo I), do clipe de titânio (grupo II) e da ligadura com fio de sutura (grupo III) para a oclusão dos vasos ovarianos e uterinos. Hemorragia e enfisema subcutâneo foram as principais complicações observadas no transoperatório e hematoma su (mais) bcutâneo e deiscência de sutura, as do pós-operatório. O procedimento cirúrgico e a técnica operatória mostraram-se viáveis nos três grupos. O uso do eletrocautério bipolar apresentou vantagens na comparação com os outros métodos de hemostasia. Resumo em inglês Twenty-four healthy female mongrel cats were submitted to ovaryhisterectomy and distributed into three groups of eight animals each: (I) bipolar electrical cautery, (II) titanium clips, and (III) suture ligature for the occlusion of ovarian and uterine vessels, which were compared. The surgical procedure and the operation technique were viable in all three groups. Hemorrhagia and subcutaneous emphysema were the main intraoperative complications, and hematoma and suture de (mais) hiscence in the postoperative. The bipolar electrical cautery procedure is shown to be comparatively successful regarding the other studied methods for hemostasia.

Scientific Electronic Library Online (Portuguese)

49

Ensaio de citotoxicidade e influência do tratamento de solubilização na microestrutura da liga Ti-35Nb-7Zr-5Ta para potenciais aplicações ortopédicas/ Cytotoxicity and influence of solution treatment on microstructure of a Ti-35Nb-7Zr-5Ta alloy for use in orthopedics prosthesis

Taddei, E. B; Henriques, V. A. R; Silva, C. R. M; Cairo, C. A. A; Bottino, M. C.
2007-01-01

Resumo em português A tendência das pesquisas atuais em próteses ortopédicas se baseia no desenvolvimento de ligas de titânio isentas de elementos com potencial tóxico e que possuam baixo módulo de elasticidade. Entre as ligas já desenvolvidas, a de composição Ti-35Nb-5Zr-5Ta se destaca das demais por apresentar o menor módulo de elasticidade, boa resistência mecânica e elevada biocompatibilidade. O processo de obtenção de ligas de titânio por metalurgia do pó (M/P) a partir (mais) dos pós elementares, mostra-se uma alternativa viável, por permitir a obtenção de peças com geometrias complexas e próximas às dimensões finais. Amostras da liga Ti-35Nb-5Zr-5Ta foram sinterizadas a 1500 ºC por 2 horas, tratadas termicamente a 1100 °C, por 3 horas, sob vácuo (10 -7 Torr) e resfriadas no forno, visando obter uma microestrutura solubilizada. A avaliação biológica foi realizada a partir de um ensaio de citotoxicidade baseado na norma ISO 10993-5, usando cultura de células de ovário de hamsters chineses em contato com extratos diluídos de três diferentes materiais: PEAD (controle negativo), CP-Ti (referência clínica), a liga Ti-35Nb-7Zr-5Ta, e a solução fenólica a 0.2% (controle positivo). Os resultados do ciclo de tratamentos térmicos da liga são coerentes com a literatura e indicam um padrão microestrutural que se baseia na presença de grãos beta com precipitados de alfa nos contornos e no interior dos grãos. O teste "in vitro" revelou a não citotoxicidade da amostra sinterizada a 1500 ºC, demonstrando a segurança da rota utilizada na obtenção de implantes odontológicos e ortopédicos. Resumo em inglês The trend of the current research in orthopedics prosthesis is based on the development of titanium alloys composed of non-toxic elements with low modulus of elasticity. The special interest in the Ti-35Nb-7Zr-5Ta alloy use for biomaterial applications is due to the lower modulus of elasticity, good mechanical strength resistance and superior biocompatibility. The process of titanium alloys production by powder metallurgy (M/P) from the elemental powders is a feasible rou (mais) te, for allowing the manufacture of parts with complex geometry and near to the final dimensions. Samples of Ti35Nb-7Zr-5Ta alloy were sintered at 1500°C/2h, heat treated at 1100 º C in vacuum (10 - 7 Torr) for 3 hours, followed by air and furnace cooling. The biological evaluation was carried out by a cytotoxicity test using Chinese Hamster Ovary (CHO) cultured cells in contact with diluted extract of three different sterile biomaterials: PEAD (negative control), CP-Ti, the alloy TNZT and phenol 0.2% (positive control). The extract preparation of the material involved in this investigation and the employed cell line were based on the International Standards Organization ISO 10993-5 (1992) guidelines. The results of the thermal treatments cycles of the TNZT alloy are coherent with literature and indicate a microstructural standard based on the presence of large beta grains with fine alpha precipitation in the grain boundaries and the interior of the grains. "In vitro" test indicated the non cytotoxicity of the Ti-35Nb-7Zr-5Ta alloy, demonstrating that the route and materials used is very secure for surgical implants production.

Scientific Electronic Library Online (Portuguese)

50

Miniplacas de ancoragem no tratamento da mordida aberta anterior/ Anchorage miniplates on anterior open-bite treatment

Ramos, Adilson Luiz; Zange, Sabrina Elisa; Terada, Hélio Hissashi; Hoshina, Fernando Toshihiro
2008-10-01

Resumo em português INTRODUÇÃO: o relato de caso apresentado descreve um tratamento ortodôntico auxiliado por miniplacas, de uma paciente adulta que apresentava mordida aberta anterior acentuada, rotação horária da mandíbula, biprotrusão e ausência de selamento labial. Após a extração dos primeiros molares e retração dentária superior e inferior, associada ao controle vertical propiciado pelas placas, ocorreu uma pequena rotação anti-horária da mandíbula e a correção da (mais) mordida aberta anterior, com significativa melhora facial. OBJETIVO: o presente relato corrobora as evidências atuais quanto à eficiência do uso de miniplacas de titânio como ancoragem temporária, especialmente em situações de correções de grande amplitude, envolvendo um problema vertical. Resumo em inglês INTRODUCTION: The case report presented describes an orthodontic treatment supported by miniplates of an adult female patient who presented severe anterior openbite, clockwise rotation of the mandible, biprotrusion and the absence of labial sealing. After extraction of first molars and maxillary and mandibulary dental retraction, associated with vertical control provided by the miniplates, the anterior openbite was corrected with a little anti-clockwise rotation, resultin (mais) g in a significant improve on facial appearance. AIM: This case report confirms the efficiency of titanium miniplates as temporary anchorage, especially in situations where great corrections are needed, involving a vertical problem.

Scientific Electronic Library Online (Portuguese)

51

Análise radiográfica computadorizada da reabsorção radicular apical após a utilização de duas mecânicas ortodônticas/ Computer-assisted radiographic evaluation of apical root resorption following orthodontic treatment with two different fixed appliance techniques

Santos, Eduardo César Almada; Lara, Tulio Silva; Arantes, Flávia de Moraes; Coclete, Gilberto Aparecido; Silva, Ricardo Santos
2007-02-01

Resumo em português OBJETIVO: a reabsorção radicular apical é uma condição comumente observada durante e após o tratamento ortodôntico e fatores como tipo de aparelhagem ortodôntica utilizada, magnitude das forças aplicadas e duração do tratamento podem estar relacionados ao processo de arredondamento do ápice radicular. Buscou-se avaliar, por meio de imagens radiográficas computadorizadas, a quantidade de reabsorção no ápice radicular, quando da utilização de duas diferent (mais) es técnicas de mecânica ortodôntica fixa: Edgewise com acessórios padrão e Edgewise com acessórios totalmente programados. METODOLOGIA: a amostra constituiu-se de 20 pacientes tratados pelo mesmo profissional na Clínica de Ortodontia da Faculdade de Odontologia de Araçatuba - UNESP. Os pacientes foram divididos em dois grupos: grupo 1 (Tratados com Edgewise com acessórios padrão e fios de aço) e grupo 2 (Tratados com Edgewise com acessórios totalmente programados e fios de níquel-titânio). A avaliação radiográfica digital foi realizada por um único operador por meio de exposições radiográficas digitais feitas no início do tratamento ortodôntico, após retração de caninos e final de tratamento, utilizando o sistema de escores proposto por Levander e Malmgren (1988). RESULTADOS E CONCLUSÕES: a análise dos escores permitiu concluir que o tratamento ortodôntico empregando a técnica Edgewise com acessórios totalmente programados e fios de níquel-titânio apresentou menores graus de reabsorção radicular apical, em comparação à técnica Edgewise com acessórios padrão e fios de aço. Observou-se que, independentemente da técnica empregada, o tratamento ortodôntico como um todo apresentou um grau moderado de reabsorção radicular apical. Resumo em inglês AIM: external apical root resorption is frequently observed during and after orthodontic treatment and can be related to factors such as mechanical factors, magnitude of forces and treatment time with fixed appliances. This study investigated by means of computerized radiographs the amount of root resorption after orthodontic treatment with two different fixed appliance techniques: standard Edgewise technique and Straight-wire system. METHODS: the sample was comprised of (mais) 20 patients treated by the same orthodontist at the Orthodontic Clinic of Araçatuba Dental School, University of São Paulo State - UNESP. The patients were divided into two groups: group 1 (treated with standard Edgewise technique and stainless steel wires) and group 2 (treated with Straight-wire system and nickel-titanium alloys). The computerized evaluation was performed by only one examiner using Levander and Malmgren’s score system (1988) in the radiographs obtained at the beginning of the orthodontic treatment, after canine retraction and at the end of treatment. RESULTS AND CONCLUSIONS: external apical root resorption in patients treated with Straight-wire system and nickel-titanium alloy was lesser than in patients treated by standard Edgewise technique and stainless steel wires. However, all patients presented moderate external apical root resorption regardless of the fixed appliance technique.

Scientific Electronic Library Online (Portuguese)

52

Avaliação da presença de monazita em concentrado de ilmenita produzido na mina do Guaju (PB)/ Evaluation of monazite presence in ilmenite concentrates produced at Guaju mine (PB)

Ferreira, Karime Ribeiro e Silva; Sabedot, Sydney; Sampaio, Carlos Hoffmann
2007-12-01

Resumo em português A ilmenita é um mineral fonte de dióxido de titânio, matéria-prima utilizada como pigmento branco na fabricação de tintas e vernizes, principalmente. O concentrado de ilmenita, avaliado nesse estudo, provém da Mina do Guaju, no Estado da Paraíba, operada pela empresa Millennium Inorganic Chemicals do Brasil S/A. Esse concentrado contém monazita, que, mesmo presente em baixa quantidade, é caracterizada como um contaminante indesejado no processo metalúrgico de f (mais) abricação do pigmento. Esse estudo avalia a maneira como a monazita está associada no concentrado de ilmenita. Análises com lupa e Microscópio Eletrônico de Varredura indicaram que a monazita se encontra como partículas liberadas no concentrado de ilmenita, em baixíssima concentração. Resumo em inglês Ilmenite is a mineral that provides titanium dioxide, which is a white pigmented raw material used mainly in the manufacture of inks and varnishes. The ilmenite concentrate, evaluated in this study, comes from the Guaju's Mine, located in the State of Paraíba ,and operated by the company Millennium Inorganic Chemicals of Brazil S/A. This concentrate contains monazite that is an undesirable contaminant, even in small amounts, for the metallurgical process of pigment manuf (mais) acture. This study evaluates the manner in which monazite is associated in the ilmenite concentrate. Analyses using microscopy and Scanning Electronic Microscopy indicated that monazite is found as free particles in the ilmenite concentrate, in minuscule concentration.

Scientific Electronic Library Online (Portuguese)

53

Microestrutura e resistência à corrosão do Ti c.p. soldado a laser utilizando em prótese sobre implantes/ Corrosion resistance and microstucture of the cp.ti welded by laser applyed for prosthesis supported by implants

BEZERRA, Roberto Messias; SOUZA, Paulo Cézar Rioli Duarte de; RAMIRES, Ivan; BOTTINO, Marco Antônio; GUASTALDI, Antônio Carlos
1999-01-01

Resumo em português Foram realizados estudos para avaliar a microestrutura, a dureza e a resistência à corrosão do titânio comercialmente puro-Ti c.p. soldado por laser e utilizado na confecção de prótese sobre implantes. Verificou-se que na soldagem a laser a microestrutura apresentou três regiões distintas: o cordão de solda, a zona afetada pelo calor - ZAC e o metal base. O Ti c.p. possui microestrutura granular, a microestrutura do cordão de solda é mais refinada e de maior d (mais) ureza do que o metal base. A ZAC obtida por este processo de soldagem foi relativamente pequena quando comparada com o processo de soldagem por brasagem. Os ensaios eletroquímicos mostraram que a região da solda apresentou menor resistência à corrosão em meio de NaCl 0,15 molL-1 à temperatura ambiente. Resumo em inglês This research was developed to study the microstructure, the hardness properties and corrosion resistence of the commercial pure titanium-cp Ti to be applied for prosthesis supported by implants submeted to laser welding process. In the welding area was found three different microstructure regions: the weld fusion zone, the heat afected zone - HAZ, and the base metal. The cp Ti revealed a more refined and hardness weld zone microstructure than that base metal area. The HA (mais) Z width were smaller when compared with brazing welding process. The eletrochemical experiments showed that the weld region had a lowest corrosion resistance in NaCl 0.15 molL-1 solution at room temperature.

Scientific Electronic Library Online (Portuguese)

54

Aspectos microestruturais da falha de um aço IF deformado via compressão dinâmica a -196ºC/ Microstructural aspects of failure of an IF steel deformed by dynamic compression at -196ºC

Lins, Jefferson Fabrício Cardoso; Sandim, Hugo Ricardo Zschommler; Vecchio, Kenneth S.
2009-06-01

Resumo em português O presente trabalho reporta os resultados da caracterização microestrutural realizada em bandas de cisalhamento adiabáticas induzidas num aço IF estabilizado ao titânio, visando a avaliar a formação e o crescimento de danos. O material foi deformado via compressão dinâmica sob altas taxas de deformação (> 5,0×10(4) s-1) numa barra de impacto de Hopkinson a -196ºC. A observação detalhada das regiões de cisalhamento e das superfícies de fratura foi realizad (mais) a via microscopia eletrônica de varredura (MEV). A recristalização dinâmica no interior das bandas de cisalhamento adiabáticas foi o evento precursor, que permitiu um caminho para a propagação das fissuras. Pode-se concluir que a fratura do material foi o resultado de um processo de clivagem dirigido por maclas de deformação e bandas de deslizamento. Resumo em inglês The present work reports the results of microstructural characterization performed in adiabatic shear bands forced in titanium-stabilized IF steel to evaluate damage formation and growth. Dynamic compression tests were done at -196ºC under large strain rates (> 5.0×104 s-1) with the aid of a Split Hopkinson Bar. Scanning electron microscopy (SEM) was employed to investigate the shear regions and the fracture surfaces in detail. The dynamic recrystallization within ASB w (mais) as the precursor event and provided a path for crack propagation. It can be concluded that the failure of the material was the result of the cleavage process driven by the presence of deformation twins and slip bands.

Scientific Electronic Library Online (Portuguese)

55

Estudos eletroquímicos de ligas Ti-Mo de interesse para biomateriais/ Electrochemical studies on Ti-Mo alloys of interest to biomaterials

Oliveira, Nilson T. C.; Guastaldi, António C.
2007-04-01

Resumo em português Ligas de titânio estão sendo desenvolvidas para uso em implantes ortopédicos devido às suas propriedades mecânicas adequadas, biocompatibilidade e resistência à corrosão. Neste trabalho, foram realizados estudos eletroquímicos nas ligas Ti-Mo com 6, 10 e 20 Mo (% m/m) na estrutura bruta de fusão, em solução de Na2SO4 0,15 mol L-1 e solução fisiológica de Ringer. Os valores dos potenciais de repouso indicam que estas ligas apresentam tendência semelhante à (mais) formação de óxido espontâneo, enquanto que os perfis obtidos por voltametria cíclica mostram que estas não sofrem corrosão por pites até potenciais de crescimento iguais a 8,0 V (vs ECS). Nos estudos potenciodinâmicos associados aos cronoamperométricos as análises do potencial de circuito aberto indicaram que a presença do íon cloreto, não afeta a estabilidade dos óxidos anódicos formados. Resumo em inglês Ti alloys are being developed to be used in orthopedic implants due their mechanical properties, biocompatibility and corrosion resistance. At this paper are reported electrochemical studies on the as-cast Ti-Mo alloys with 6, 10 and 20 Mo (wt.%), in 0.15 mol/L Na2SO4 solution and Ringer physiological solution. Analyses of the rest-potential indicated that all alloys present the same tendency to a spontaneous passivation, while cyclic voltammograms showed not transpassiva (mais) tion up to potentials of 8,0 V (vs ECS), indicating high corrosion resistance. The comparison among open-circuit profiles of the anodic oxides growth in Ringer and Na2SO4 solutions, are showing that the presence of chloride ions during the anodization is not influencing the oxides chemical stability.

Scientific Electronic Library Online (Portuguese)

56

Influência de aditivos na rigidez dielétrica do polietileno de alta densidade/ Additives influence on the high density polyethilene breakdown strenght

Ueki, Marcelo M; Zanin, Maria
1997-12-01

Resumo em português Neste trabalho são apresentados resultados de ensaios de ruptura dielétrica de curta duração com rampa de tensão positiva em amostras de polietileno de alta densidade (HDPE), modificadas com diferentes níveis de aditivos (dióxido de titânio, negro de fumo, antioxidante e estabilizante à ultravioleta). Esses resultados foram analisados estatisticamente pela distribuição de Weibull. Os parâmetros desta distribuição (β e Eγ) foram determinados pelos m (mais) étodos Gráfico e de Máxima Verossimilhança. Pôde-se concluir que os aglomerados de negro de fumo são prejudiciais à rigidez dielétrica e que o parâmetro de forma β desta distribuição pode ser empregado para avaliar as condições de mistura dos componentes na formulação, as quais afetam a rigidez dielétrica. Por meio de microscopia ótica pôde-se verificar que o parâmetro β, quando determinado pelo método Gráfico, representa melhor a dispersão dos referidos aditivos na matriz polimérica. Resumo em inglês In this work, it is presented results of the short-time dielectric breakdown test in high-density polyethylene (HDPE), with different additives levels (titanium dioxide, carbon black, antioxidant and UV stabilizer). For the dielectric breakdown test, an automated system developed in this department's polymer electrical properties lab has been used. The results have been analized by Weibull distribution. The parameters of Weibull distribution have been obtained by Graphica (mais) l and Maximum Likelihood methods. One concluded that shape parameter β can be used to evaluate additives mixing condition in the compounds and graphical method better represents scattering of the results.

Scientific Electronic Library Online (Portuguese)

57

Tenacidade à fratura translaminar dinâmica de um laminado híbrido metal-fibra para uso em elevadas temperaturas/ Translaminar dynamic fracture toughness of a hybrid fiber-metal laminate devised to high-temperature applications

Tarpani, José R.; Gatti, Maria C. A.
2010-01-01

Resumo em português A tenacidade à fratura translaminar dinâmica do laminado híbrido metal-fibra titânio-grafite com matriz termoplástica foi determinada sob as velocidades de impacto de 2,25 e 5,52 m/s, no intervalo de temperaturas de -196 a +180 °C, e comparada à de laminados compósitos convencionais de fibras de carbono e resina epóxi. Constatou-se que o laminado híbrido exibe uma tenacidade à iniciação da fratura inferior à dos compósitos tradicionais com fibras na forma d (mais) e fita unidirecional, porém superior à dos laminados convencionais com fibras na forma de tecido bidirecional. Os ensaios de impacto revelaram que, comparativamente ao desempenho mecânico dos laminados carbono-epóxi, o emprego do laminado híbrido metal-fibra se justifica mais pela sua resistência à propagação do que à iniciação da fratura dinâmica. Resumo em inglês The translaminar dynamic fracture toughness of titanium-graphite hybrid fiber-metal laminate with thermoplastic matrix has been determined at the impact velocities of 2.25 and 5.52 m/s, within the temperature range from -196 to +180 ºC, and compared to that of conventional carbon-epoxy composite laminates. The hybrid laminate exhibits lower initiation fracture toughness than traditional unidirectional tape composites though it is tougher than conventional woven fabric la (mais) minates. Impact tests revealed that, if compared to the mechanical performance of conventional carbon-epoxy laminates, the fiber-metal laminate application must rely on its resistance to dynamic fracture propagation rather than on fracture initiation.

Scientific Electronic Library Online (Portuguese)

58

Colopexia laparoscópica com retalho de tela de polipropileno em cães/ Laparoscopic colopexy with polyprolyne mesh in dogs

Brun, M.V.; Guimarães, L.D.; Barcellos, H.H.A.; Guizzo Júnior, N.; Pereira, R.A.
2007-02-01

Resumo em português Avaliou-se uma nova técnica de colopexia laparoscópica, sem necessidade de suturas intracorpóreas em cães, utilizando a implantação de segmento de tela de polipropileno em 11 animais. As superfícies serosas do cólon descendente e parede muscular foram mantidas em contato com o implante posicionado por meio de lesão produzida no mesocólon e sob o retalho bipediculado de músculo transverso abdominal. As extremidades da tela foram unidas com a aplicação de clipe (mais) de titânio. Os procedimentos duraram 36,00±13,15min, sem a ocorrência de complicações. No período pós-operatório, foi verificada a manutenção da colopexia em sete animais, a formação de fixação parcial entre o intestino e a parede em três cães, e a não formação de aderências do cólon em um paciente. Conclui-se que o procedimento proposto é viável para cães, porém necessita de ajustes técnicos. Resumo em inglês A new laparoscopic colopexy technique was tested in dogs without intracorporeal sutures. The use of polypropylene mesh in eleven mongrel dogs was evaluated. The serosal surface of the descendent colon and transverse abdominal muscle were put in contact with the mesh application, taking into consideration that the polypropylene implant was positioned through the mesocolon and under the muscle flap. Finally, the extremities of the mesh were clipped. The procedures lasted 36 (mais) :00±13:15min, without any kind of complications. In the post-operative period, adequate colopexy in seven dogs was observed. In three dogs the colopexy was partial and in one the bowel did not adhere to the muscles or mesh. The proposed procedure is viable for dogs, however, it is necessary to make some adjustments.

Scientific Electronic Library Online (Portuguese)

59

Efeito das impurezas dos clínqueres coprocessados sobre sua quebra em Drop Weigth Tester (DWT)/ Impurities effect from coprocessed clinkers on their breakagein Drop Weight Tester (DWT)

Souza, Vládia Cristina G. de; Koppe, Jair Carlos; Costa, João Felipe Coimbra Leite
2010-12-01

Resumo em português Nesse estudo, é verificada a possível existência de correlação entre as impurezas presentes nos componentes cristalinos dos clínqueres coprocessados com sua resistência à quebra (determinada em Drop Weigth Tester - DWT). Esse ensaio é usado para prever a moabilidade desses materiais, fornecendo o parâmetro de impacto (A.b). Quanto maior o valor do parâmetro de impacto, menor é a resistência à quebra do clínquer. Para os clínqueres testados, foi, também, d (mais) eterminado o conteúdo médio (% em massa) de impurezas nas fases cristalinas, incluindo álcalis, bário, estrôncio, manganês e titânio. Para isto, foi usada microanálise com sistema de EDX (Energia dispersiva de Raios X) acoplado ao MEV (Microscópio Eletrônico de Varredura). A análise estatística dos resultados químicos sugere forte correlação entre as impurezas e o parâmetro de impacto A.b. Resumo em inglês In this study, the possible correlation between impurities presented in the crystalline compounds of the coprocessed clinkers and their breakage strength (determined by Drop Weigth Tester-DWT) is verified. This latter is used to predict the grindability of these materials by providing the impact parameter (A.b). The higher the impact parameter is, the lower the breakage strength is. For the tested clinkers, the average content (wt. %) of impurities in the crystallized pha (mais) ses, including alkalies, barium, strontium, manganese and titanium was determined. For this, microanalysis with an EDX (Energy Dispersive X-Ray) system coupled to the SEM (Scanning Electron Microscopy) was used. The statiscal analysis of the chemical results suggests a strong correlation between the impurities and impact parameter.

Scientific Electronic Library Online (Portuguese)

60

Avaliação da resistência à torção em parafusos utilizados em implantes - um panorama brasileiro/ The torsion strength of orthopedic implant screws - a suvey of brazilian samples

Kliauga, Andrea Madeira; Silva, Paulo Sergio Carvalho Pereira da; Girodano, Enrico J.; Epiphanio, Ivan Della Vale; Canimaga, Celio; Bolfarini, Claudemiro
2010-03-01

Resumo em português Desde 2004, o CCDM realiza ensaios mecânicos em implantes ortopédicos. Os componentes mais utilizados - e conseqüentemente ensaiados - são parafusos, comumente fabricados com aço inoxidável ASTM F138, ou liga de titânio ASTM F136. O objetivo desse trabalho é avaliar os resultados referentes aos ensaios de torção em parafusos metálicos, dando um panorama das propriedades médias dos produtos ensaiados. Tais resultados provieram de material fornecido por 15 fabri (mais) cantes diferentes, num total de 451 ensaios, que cobriram quase todo o espectro de parafusos utilizados em implantes: ortodontia, parafusos pediculares, parafusos para ossos corticais e esponjosos, parafusos de bloqueio e de ancoragem. A dispersão dos resultados de ângulo de ruptura é elevada. A maioria dos resultados, no entanto, apresenta valores acima do mínimo exigido pela norma ASTM F543. Resumo em inglês Since 2004, the CCDM lab performs tests on orthopedic implants. The most used (and tested) implants are screws. These are commonly made either of austenitic stainless steel ASTM F138 or of Ti-6Al-4V alloy ASTM F136. The aim of this study was to evaluate the obtained torsion test results and to present an overview of the average product properties. The results stand for 15 different producers, and 451 samples, covering almost all the screw types utilized in implants: ortho (mais) dontic, anchor and tibial nail applications, and designs for pedicular, cortical and cancellous bones. The dispersion in angle of rupture was high. Nevertheless the majority of the results lied above the minimum required by the ASTM F543 standard.

Scientific Electronic Library Online (Portuguese)

61

DESENVOLVIMENTO DE UMA ESCALA EM SILICONA PARA TONS DE PELE HUMANA/ DEVELOPMENT OF A SILICONE SCALE FOR SHADES OF HUMAN SKIN

NEVES, Ana Christina Claro; VILLELA, Lauro Cardoso
1998-01-01

Resumo em português O autor desenvolveu em silicona uma escala de tonalidades de pele humana. Foram confeccionados vinte e sete corpos-de-prova em silicona acética (Silastic 732 RTV), pigmentados com óxidos de ferro e dióxido de titânio. A quantidade de silicona acética manteve-se constante (dois gramas) em todos os corpos-de-prova, e os pigmentos foram misturados a ela em várias proporções até a obtenção de vinte e sete diferentes tonalidades. Através da comparação da cor dos (mais) corpos-de-prova com a cor da pele de quarenta e um indivíduos, foram selecionados os cinco corpos-de-prova com as tonalidades que mais se igualavam à cor da pele dos pacientes, compondo, assim, um guia de tonalidades. Com a metodologia empregada, foi possível desenvolver uma escala de tonalidades de pele que poderá facilitar a definição do tom da pele do paciente quando da confecção de próteses faciais em silicona, permitindo economia de tempo e de material no momento da seleção da cor. Resumo em inglês The author developed a scale in silicone of shades of human skin. Twenty-seven samples were produced in acetic silicone (Silastic 732 RTV), pigmented with iron oxides and titanium dioxide. The amount of acetic silicone was kept constant (two grams) in all of the samples, and the pigments were mixed to it in varying proportions, until twenty-seven different shades were obtained. By comparing the color of the samples with the skin color of forty-one individuals, five sample (mais) s were selected of the shades that best matched a patient's color of skin to form a shade guide. With the methodology employed, it was possible to develop a shade guide that will facilitate a definition of a patient's skin color in producing facial prostheses in silicone, to afford economy in time and in material at time for selecting the color.

Scientific Electronic Library Online (Portuguese)

62

Correlação entre o espectro óptico e a concentração de impurezas no quartzo colorido

Araújo, Fernando Gabriel S.; Cerceau, Cristiano R.; Cota, André B.; Pereira, Breno A.
2001-12-01

Resumo em português Gemas de quartzos naturais branco-leitoso, fumês, ametista, citrino verde e rosa foram caracterizados por espectrometria UV-VIS, microssonda eletrônica, difratometria de raios X e por espectrometria de absorção atômica, com o objetivo de avaliar as fases presentes e as concentrações de impurezas. Para toda a região do visível, o quartzo incolor leitoso apresentou a maior absorção, enquanto os quartzos citrino e enfumaçado apresentaram os menores níveis de abs (mais) orção. Observou-se a presença de Al em todas as amostras, em quantidades próximas ou superiores à encontrada no quartzo fumê. A concentração de ferro na ametista, no quartzo-citrino e no quartzo verde revelou-se crescente de um tipo para outro. No quartzo rosa translúcido, o titânio foi detectado em quantidades apreciáveis, não tendo sido quantificados o fósforo ou o ferro, de maneira que se pode necessitar de maior investigação para se definir o mecanismo causador de cor, embora ele deva estar seguramente ligado à presença dos íons Ti. Resumo em inglês Natural quartz stones, presenting the colors white, smoky, violet (ametist), citrine, green and pink, where characterized by UV-VIS spectrometry, electron microprobe, X ray diffraction and atomic absorption spectrometry, to determine the fases and impurities in the gems. In the visible portion of the spectrum, the white quartz presented the highest levels of absorption, whilst the citrine and smoky samples showed the highest levels of transmission. Aluminum impurities whe (mais) re found in all samples, in higher quantities than that detected in the smoky quartz. The ametist, the citrine and the green quartz showed increasing levels of iron impurities. In the translucent pink quartz, titanium was associated to the color, however, neither iron nor phosphorus were detected, indicating the need of further investigation to determine the exact color mechanism.

Scientific Electronic Library Online (Portuguese)

63

Fixação occípito-cervical "inside-outside": relato técnico/ Inside-outside occipito-cervical fixation: technical report

Castro, Igor de; Landeiro, José Alberto
2003-06-01

Resumo em português O entendimento sobre a biomecânica do complexo occípito-atlanto-axial explica a instabilidade progressiva após a descompressão anterior da junção craniocervical.O propósito do presente relato é descrever a técnica de fixação occípito-cervical tipo "inside-outside" proposta por Pait et al., e os resultados em dois pacientes operados pela via transoral para remoção da apófise odontóide. A técnica utiliza uma haste de titânio moldada para adaptar-se à curv (mais) atura occipital e colocada lateralmente até a coluna cervical; a haste é fixada no osso occipital por meio de parafuso cuja parte achatada é colocada no espaço epidural. Na coluna cervical, a haste é fixada por parafusos que são introduzidos no quadrante súpero-lateral das massas articulares. No axis, o parafuso é introduzido na "pars interarticulares" podendo terminar no próprio corpo desta vértebra ou na massa articular do atlas. Esta técnica revelou-se segura e de fácil aplicabilidade. Resumo em inglês The clinical knowledgement of biomechanics of atlantoaxial complex have been proved that progressive instability has a mandatory occurrence after anterior decompression of the craniocervical junction. We report the occípitocervical fixation so called inside-outside technique, originally described by Pait et al. appliedin in two patients whom underwent odontoidectomy. The occipitalcervical fixation technique consist in the use of a titanium rod bended according with occip (mais) ital cervical angle placed and fixed laterally over the cervical spine. The rod is fixed to the occipital bone by mean of placement a screw which flat portion is positioned onto the epidural space. In the cervical spine the rod is attached to transarticular screws placed at the superolateral quadrant of the articular mass. In the axis the screw is introduced through the pars interarticularis finishing at the axis body or the lateral mass of the atlas. This technique proved to be safe and easily applied in the patients whom underwent this surgical procedure.

Scientific Electronic Library Online (Portuguese)

64

Tratamento da espondilólise sintomática com reparo direto pela técnica de Buck modificada/ Modified Buck's direct repair to simptomatic spondylolysis treatment/ Tratamiento de la espondilolisis sintomática con preparo directo por la técnica de Buck modificada

Fontes, Bruno Pinto Coelho; Resende, Maurício Erwin Pühler; Rezende, Carlos Moreira; Macedo, Rodrigo D'Alessandro de; Pedrosa, Luis Olímpio Garcia; Leal, Jefferson Soares; Resende, Rogério Lúcio Chaves de
2009-03-01

Resumo em português OBJETIVO: justificar a reconstrução da pars interarticularis pela técnica modificada de Buck como método efetivo no tratamento de lombalgia por espondilólise ou espondilolistese tipo 1, refratárias ao tratamento conservador. MÉTODOS: avaliação retrospectiva de oito pacientes com idade entre 11 e 34 anos, operados e acompanhados no período de outubro de 2004 a maio de 2008 com a técnica de Buck utilizando-se parafusos canulados de titânio. Nenhum paciente foi i (mais) mobilizado no pós-operatório. Os pacientes foram selecionados após serem submetidos a estudos por imagem utilizando radiografias e ressonância magnética. Também foram avaliados no pós-operatório, segundo os critérios de Henderson e quanto à satisfação com o tratamento, assim como o índice de consolidação. RESULTADOS: sete pacientes foram classificados como excelentes, retornando ao nível de prática esportiva e laboral prévia. Dentre eles, um evoluiu com parestesia transitória, com recuperação completa. A oitava paciente apresentou uma pseudartrose bilateral, mas com bom resultado do ponto de vista clínico. Todos os pacientes ficaram satisfeitos com o resultado. CONCLUSÃO: a reconstrução ístmica com parafusos de titânio atingiu excelentes resultados ao aliar biomecânica estável, dissecção mínima da musculatura, com preservação da anatomia e mobilidade do segmento. Resumo em espanhol OBJETIVO: justificar la reconstrucción de la pars interarticularis por la técnica modificada de Buck como método efectivo en el tratamiento de la lumbalgia por espondilosis o espondilolistesis tipo 1, refractarias al tratamiento conservador. MÉTODOS: evaluación retrospectiva de ocho pacientes con edad entre 11 a 34 años, operados y acompañados en el periodo de Octubre de 2004 hasta Mayo de 2008 con la técnica de Buck usando tornillos canulados de titanio. Ningún (mais) paciente fue inmovilizado en el postoperatorio. Los pacientes fueron seleccionados después de ser sometidos a estudios por imagen utilizando radiografías y resonancias magnéticas. También fueron evaluados en el postoperatorio, según los criterios de Henderson y el grado de satisfacción con el tratamiento, así como también el índice de consolidación. RESULTADOS: siete pacientes fueron clasificados como excelentes, retornando al nivel de práctica deportiva y laboral previa. Dentro estos siete pacientes, uno evolucionó con parestesias transitorias, con recuperación completa. La octava paciente presentó una pseudoartrosis bilateral, pero con buen resultado desde el punto de vista clínico. Todos los pacientes quedaron satisfechos con el resultado. CONCLUSIÓN: la reconstrucción ístmica con tornillos de titanio tuvo excelentes resultados al juntar biomecánica estable, disección mínima de la musculatura, con preservación de la anatomía y modalidad del segmento. Resumo em inglês OBJECTIVE: to justify the modified Buck's technique of pars reconstruction as an effective method to spondylolysis and low grade spondylolisthesis treatment. METHODS: eight patients with ages 11 to 34 years were retrospectively evaluated from October 2004 to may 2008. They were operated with Buck´s technique using titanium canulated screws. Immobilization wasn't used in any patient in post-operative period. All patients were studied with magnetic resonance imaging. All p (mais) atients were assessed in post-operative period with Henderson's criteria of functional capacity. RESULTS: seven patients were assessed as excellent. They didn´t complain pain and were able to return to former occupation and sportive activities. One patient presented temporary paresthesia and leg weakness, and one patient bilateral pseudoarthrosis that cursed with good grade functional capacity. All patients were satisfied with treatment. CONCLUSION: the isthmic reconstruction using titanium screws allowed excellent results allied with stable biomechanics, minimal injury to back muscles, preservation of anatomy and segmental mobility, and better operated spinal imaging.

Scientific Electronic Library Online (Portuguese)

65

Utilização de microparafusos ortodônticos na correção de assimetrias/ The use of orthodontic microscrews in the asymmetries correction

Villela, Henrique Mascarenhas; Sampaio, Andréa Lacerda Santos; Bezerra, Fábio
2008-10-01

Resumo em português INTRODUÇÃO: o controle da ancoragem é de fundamental importância para o sucesso do tratamento ortodôntico, principalmente na correção das assimetrias, onde se torna ainda mais crítico. Os métodos convencionais de ancoragem utilizados para tratar estes tipos de anomalia são mais complexos e podem causar movimentos indesejáveis na unidade de reação ou, ainda, ser rejeitados pelos pacientes, devido ao comprometimento estético. A utilização de microparafusos c (mais) omo unidades de ancoragem, além de anular os efeitos colaterais indesejáveis, simplifica a mecânica ortodôntica, fornece uma maior previsibilidade ao resultado do tratamento, proporciona maior conforto e estética ao paciente, reduz o tempo de tratamento e possibilita a correção de casos com perdas dentárias, já que fornece uma ancoragem direta. OBJETIVO: realizar uma revisão de literatura sobre o tratamento das assimetrias dentárias com o uso de microparafusos ortodônticos de titânio como ancoragem, ilustrando-a com alguns casos clínicos. Resumo em inglês INTRODUCTION: The control of anchorage is of crucial importance to the success of the orthodontic treatment, specially in the correction of asymmetries, where it plays a most critical role. The conventional anchorage methods used to treat those types of anomaly are more complex and may cause undesirable movements in the reaction unit, or else, be rejected by the patients due to the esthetic involvement. The use of microscrews as anchorage unit not only nullifies the undes (mais) irable side effects, but also simplifies the orthodontic mechanics, provides a greater predictability of the treatment outcome, gives the patient more comfort and better esthetic results, shortens the treatment length, and enables the correction of dental loss cases, since it provides direct anchorage. AIM: To carry out a review of the literature on the treatment of dental asymmetries using titanium orthodontic microscrews as anchorage, illustrating it with some clinical cases.

Scientific Electronic Library Online (Portuguese)

66

Influência do vanádio nas propriedades morfológicas estruturais e fotoluminescentes do titanato de zinco (Zn2TiO4)/ Influence of vanadium on the morphological, structural and photoluminescent properties of zinc titanate - Zn2TiO4

Chaves, A. C.; Câmara, M. S. C.; Sales, L. L. M.; Araújo, A . G.; Santos, I. M. G.; Melo, D. M. A.; Longo, E.
2005-09-01

Resumo em português Neste trabalho o método do precursor polimérico foi usado para obter a fase Zn2TiO4 dopada com V5+. As fases foram obtidas depois que o pó precursor foi submetido a diferentes temperaturas; a caracterização do composto foi feita por meio de difração de raios X, análise térmica e fotoluminescência. A difícil entrada do vanádio na rede polimérica conduziu à segregação na resina e também no óxido final. Depois da dopagem a temperatura de decomposição tér (mais) mica foi diminuída de 438 ºC a 420 ºC. Os pós calcinados a 400 °C e 500 °C apresentaram uma solução sólida substitucional entre os íons metálicos Ti4+ e V5+, além de formação de fase secundária. Uma diminuição do volume da cela unitária depois da adição de vanádio foi observada. A cristalinidade relativa e o tamanho de cristalito apresentaram uma variação de tamanho devido a difícil substituição do vanádio pelo titânio. Foram obtidos os melhores resultados de propriedade fotoluminescente para a amostra com 0,2 mol% de vanádio. Resumo em inglês In this work the polymeric precursor method was used to obtain the Zn2TiO4 doped with V5+. The phases were obtained after calcination the respective precursor powders at different temperatures, and their characterization was accomplished by X ray diffraction, thermal analysis and photoluminescence. It was difficult for vanadium to get into the polymeric net, leading to segregation in the resin and also in the final material. After doping, the thermal decomposition tempera (mais) ture decreased from 438 ºC to 420 ºC. The powders calcined at 400 °C and 500 °C presented a substitutional solid solution between Ti4+ and V5+ metallic ions, besides secondary phase formation. A decrease of the volume unit cell after vanadium addition was observed. Relative crystallinity and crystallite size presented a random variation due to the difficulty for vanadium substituting titanium. The best results of photoluminescent properties were obtained for the sample with 0.2 mol% of vanadium.

Scientific Electronic Library Online (Portuguese)

67

Tratamento cirúrgico do ameloblastoma com reconstrução de mandíbula com enxerto de crista ilíaca não vascularizado: estudo de sete casos/ Surgical treatment of the ameloblastoma of the mandible and reconstruction with non vascularized iliac crest graft: study of seven cases

Lunardi, Daniela Venturoli; Fava, Antonio Sérgio; Martins, Rui Henriques; Homem, Maria da Graça Naclério; Rapoport, Abrão; Carvalho, Marcos Brasilino de
2001-02-01

Resumo em português OBJETIVO: Determinar a validade do enxerto autólogo de crista ilíaca não vascularizado no tratamento cirúrgico do ameloblastoma de mandíbula. MÉTODO: Nos Serviços de Cirurgia de Cabeça e Pescoço e Semiologia Bucal do Complexo Hospitalar Heliópolis, de 1980 a 2000, foram tratados 31 pacientes com ameloblastoma de mandíbula, dos quais sete receberam enxerto de crista ilíaca autólogo, fixos com placa de titânio do sistema A-0 (quatro casos) e aço inox (três c (mais) asos), sendo portadores da variedade folicular (seis casos) e plexiforme (um caso). RESULTADOS: Nesta análise, foi utilizado o Teste de Hipótese para a média populacional com a variança desconhecida, houve exposição da placa em três casos (40%) quando a neoplasia ultrapassava a linha média e em quatro casos (60%) não incidiu nenhuma complicação. CONCLUSÕES: Apesar da incidência de exposição de placa, o método é indicado na reconstrução da mandíbula de pacientes com ameloblastoma. Resumo em inglês BACKGROUND: To determine of the real validity of non vascularized iliac crest graft in the surgical treatment of ameloblastoma of the mandible. METHODS: From 1980 to 2000, at the Head and Neck and Oral Semiology Services of Heliópolis Hospital, 29 patients were submitted to differents approaches, from which 7 received a non-vascularized autologus iliac crest graft fixed with A-0 titanium (4 cases) or inox (3 cases) systems plates for folicular (6 cases) and plexiform (1 (mais) case) ameloblastomas. RESULTS: We used a test of hypothesis for the population mean with unknown in variance. There was plate exposition in 3 cases (40%), when the tumor overpass midline, and complete sucess in 4 cases (60%) with no complications of this reconstructive approach for mandible ameloblastoma. CONCLUSIONS: In spite of the incidence of plate expesure, this technique is indicated for mandible reconstruction in patients with amelablastoma.

Scientific Electronic Library Online (Portuguese)

68

Características da superfície e da fenda implante-intermediário em sistemas de dois e um estágios/ Characteristics of implant surface and implant-abutment gap in two- and one-stage systems

Joly, Julio Cesar; Lima, Antonio Fernando Martorelli de
2003-06-01

Resumo em português O objetivo deste estudo foi avaliar em microscopia eletrônica de varredura as características da superfície e da fenda existente entre os componentes de implantes de dois e um estágios. Foram selecionados 3 implantes de dois estágios revestidos com fosfato de cálcio cerâmico (RBM) e 3 implantes de um estágio revestidos com plasma de titânio (TPS). Nos implantes de dois estágios, os intermediários tipo esthetic-cone foram adaptados ao hexágono externo e travado (mais) s com parafuso com torque definitivo de 20 N/cm. Nos implantes de um estágio foram utilizados intermediários sólidos que foram adaptados e fixados por travamento friccional com torque definitivo de 30 N/cm. Os espécimes foram montados em stubs e analisados em microscopia eletrônica de varredura. A fenda foi medida em quatro pontos com três repetições em cada implante. Os valores obtidos foram avaliados pelo teste t pareado de Student. Os resultados mostraram que não houve diferença estatística significativa (P > 0,05) na extensão da fenda entre os sistemas de um e dois estágios e que os tratamentos proporcionaram diferentes características de superfície. Resumo em inglês The aim of this study was to evaluate under scanning electron microscopy the characteristics of the implant surface and the gap between the components of two- and one-stage systems. Three two-stage implants coated with RBM and three one-stage implants coated with TPS were selected. In the two-stage implants, the esthetic-cone abutments were adapted and screw tightened with 20 N/cm . In the one stage implants, solid abutments were adapted and torque tightened mechanical fr (mais) ictional with 30 N/cm. The specimens were mounted on stubs and analyzed under scanning electron microscopy. The gap in each implant was measured in four different points and repeated three times. The paired Student-t test was applied to detect the difference in the gap extension. The results showed that no significant differences (P > 0.05) were found regarding the gap extension between two- and one-stage systems and that the treatments produced different surface roughness.

Scientific Electronic Library Online (Portuguese)

69

Avaliação qualitativa em modelo experimental fotoelástico do sistema de força gerado pela mola "T" centralizada com pré-ativações preconizadas por Burstone/ Qualitative evaluation in photoelastic experimental models of the force system generated by T-springs placed in the center of the interbracket space with pre-activations advocated by Burstone

Maia, Luiz Guilherme Martins; Gomes, Vanderlei Luiz; Santos-Pinto, Ary dos; Monini, André da Costa; Gandini-Jr, Luiz Gonzaga
2011-02-01

Resumo em português OBJETIVO: avaliar o sistema de forças gerado pela mola T centralizada no espaço interbraquete, com pré-ativação preconizada por Burstone. MÉTODOS: utilizando-se modelos fotoelásticos, a mola T com pré-ativações preconizadas por Burstone, confeccionada com fio retangular de titânio-molibdênio (TMA) de secção 0,017"x 0,025", centralizada e com ativação de 6mm, 3mm e em posição neutra. Para melhor confiabilidade dos resultados, os testes foram repetidos em (mais) três modelos igualmente duplicados e confeccionados pelo mesmo operador. Utilizou-se uma distância interbraquetes de 27mm. Para compreensão dos resultados, as franjas foram visualizadas através do polariscópio, fotografadas e analisadas qualitativamente. RESULTADOS: por meio da análise qualitativa da ordem de franjas no modelo fotoelástico, notou-se que, nas extremidades de retração e ancoragem, ambas apresentaram simetria no sistema de força, em toda extensão radicular. Resumo em inglês OBJECTIVE: To evaluate the force system generated by T-springs placed in the center of the interbracket space using the pre-activations advocated by Burstone. METHODS: Photoelastic models were used to assess T-springs fabricated with 0.017x0.025-in rectangular titanium-molybdenum alloy wire (TMA), centrally positioned, with 6.0 mm activation, 3 mm activation, and in neutral position. To ensure reliable results, tests were repeated on three photoelastic models equally dupl (mais) icated and fabricated by the same operator. An interbracket distance of 27.0 mm was used. For a better understanding of the results, the fringes were viewed in a polariscope, then photographed and qualitatively analyzed. RESULTS: Through qualitative analysis of the fringe order in the photoelastic model it was noted that both the retraction and anchorage ends displayed force system symmetry across the full extent of the root.

Scientific Electronic Library Online (Portuguese)

70

Compósitos de PVC reforçados com fibra de vidro: utilização de técnicas de processamento convencionais da indústria brasileira/ Glass fiber reinforced PVC composites: use of conventional processing techniques currently employed in the brazilian industry

Feltran, Murilo B.; Diaz, Francisco R. V.
2007-12-01

Resumo em português Este artigo apresenta o estudo da incorporação de fibra de vidro curta em composto rígido de poli(cloreto de vinila) - PVC - por meio de técnicas de processamento convencionais da indústria brasileira. Foram avaliadas as influências de: a) tamanho de fibra de vidro (tipo E); b) dosagem de fibra de vidro; c) dosagem de dióxido de titânio (TiO2); e d) a temperatura de processamento nas propriedades físicas e mecânicas e na adesão entre a matriz polimérica e a fi (mais) bra de vidro (Microscopia Eletrônica de Varredura - MEV). O custo-benefício dos compósitos foi calculado por meio de Índices de Mérito para os modos de carregamento mecânico encontrados nos tubos pressurizados para água fria (Cilindro com Pressão Interna) e perfis rígidos utilizados em construção civil (Barra em Flexão), devido ao grande uso de PVC nestas aplicações. Entre os resultados obtidos, destaca-se o aumento de 45% no módulo de elasticidade para os compósitos com 20% de fibra de vidro moída que, para algumas aplicações, pode apresentar uma relação custo-benefício bastante favorável. Resumo em inglês This article presents the impact of the short glass fiber incorporation in rigid PVC compound through conventional processing techniques currently employed in the Brazilian industry. It were studied the influences of a) glass fiber geometry (E type); b) glass fiber content; c) titanium dioxide content; and d) processing temperature in the physical and mechanical properties. The adhesion conditions between polymeric matrix and glass fiber was analyzed by scanning electron (mais) microscopy (SEM). Cost-benefit relation of composites was evaluated using materials index technique for mechanical conditions found in pressurized water pipes (cylinder with internal pressure) and in building construction profiles (beam loaded in bending). The results attained suggested that, in some cases, the mechanical properties enhancement (such as the increase of 45% in the modulus of elasticity for composites containing 20% of glass fiber) and the processing techniques required to produce it can present an interesting cost-benefit relation.

Scientific Electronic Library Online (Portuguese)

71

Expansão rápida da maxila ancorada em implantes: uma nova proposta para expansão ortopédica na dentadura permanente/ Rapid maxillary expansion anchored by implants: a new proposal to orthopedic expansion in the permanent dentition

Garib, Daniela Gamba; Navarro, Ricardo de Lima; Francischone, Carlos Eduardo; Oltramari, Paula Vanessa Pedron
2007-06-01

Resumo em português OBJETIVO: este trabalho apresenta um método para expansão ortopédica da maxila, na dentadura permanente, utilizando implantes como ancoragem. METODOLOGIA: detalharam-se os procedimentos cirúrgicos e laboratoriais da confecção de um expansor com ancoragem dento-óssea em crânio seco humano. Dois implantes de titânio foram colocados na região anterior do palato, e o parafuso Hyrax adaptado de modo que a expansão ancorou-se nos implantes e nos primeiros molares per (mais) manentes. RESULTADOS: o experimento laboratorial em crânio seco mostrou que o procedimento apresenta-se anatômica e operacionalmente viável. Os implantes suportaram a força gerada pela ativação do parafuso expansor, redundando na separação transversal das hemimaxilas. CONCLUSÕES: vislumbra-se que a expansão rápida da maxila ancorada em implantes (ERMAI) poderá potencializar a eficiência da expansão ortopédica, assim como reduzir o custo periodontal dos procedimentos convencionais de expansão. Futuros estudos clínicos são necessários para testar essas hipóteses. Resumo em inglês AIM: This study presents a method for maxillary orthopedic expansion, in the permanent dentition, using implants as anchorage. METHODS: Surgical and laboratorial procedures for the construction of a tooth-bone-borne expansor was detailed in a human dry skull. Two titanium implants were placed in the anterior region of the palate and a Hyrax screw was adapted in a way that the expansion was anchored both on the palatal implants and on permanent first molars. RESULTS: The l (mais) aboratorial experiment in dry skull showed that the procedure is operationally and anatomically possible. The implants supported the force generated by the expansion screw activation and the maxilla halves were transversally split. CONCLUSIONS: Rapid maxillary expansion anchored on implants can increase the efficiency of orthopedic expansion and decrease the periodontal sequela caused by conventional RME. Further clinical studies are necessary to verify these hypotheses.

Scientific Electronic Library Online (Portuguese)

72

Síntese de hidroxiapatita pelo método sol-gel utilizando precursores alternativos: nitrato de cálcio e ácido fosfórico/ Synthesis of hydroxyapatite by sol-gel method using alternative precursors: calcium nitrate and phosphoric acid

Santos, M. L.; Florentino, A. O.; Saeki, M. J.; Aparecida, A. H.; Fook, M. V. Lia; Guastaldi, A. C.
2005-09-01

Resumo em português A hidroxiapatita [Ca10(PO4)6(OH)2, HA] foi sintetizada utilizando-se a rota sol-gel partindo-se de ácido fosfórico e nitrato de cálcio como precursores de cálcio e fósforo, respectivamente e como solvente utilizou-se o metanol na preparação do sol que posteriormente será utilizado na obtenção de recobrimentos de hidroxiapatita sobre substratos de ligas de titânio. O sol permaneceu estável e não ocorreu gelatinização em temperatura ambiente durante sete dias (mais) . O sol transformou-se em um gel branco somente após a remoção do solvente a 100ºC. O produto assim obtido foi calcinado em 300°C, 500°C e 700°C e caracterizou-se por DRX, FT-IR, MEV/EDS e TGA/DSC. As fases de HA sintetizada tornaram-se estáveis sem sub-produtos a 700°C. A difração de raios X mostrou que a estrutura apatita é aparente em 300°C. O tamanho do cristal e o teor de HA aumentaram com o aumento da temperatura de calcinação. A análise por MEV mostrou a presença de poros que são importantes para aplicações biomédicas, favorecendo a adesão entre o tecido ósseo neoformado e a apatita sintética, ou seja, osseointegração. Resumo em inglês Hydroxyapatite [Ca10(PO4)6(OH)2, HA] was synthesized using sol-gel route were used phosphoric acid and calcium nitrate as calcium and phosphorous precursors, respectively and as solvent was using the methanol in the preparation of the sol that later will be used in the obtention apatites coatings on titanium alloys substrates. The sol remained stable and no gelling occurred in ambient environment for over 7 days. The sol became a white gel only after the removal of the so (mais) lvent at 100ºC. The product was calcined in 300°C, 500°C and 700°C and had been characterized by DRX, FT-IR, SEM/EDS and TGA/DSC. The synthesized HA became stable 700°C without any another product. X ray diffraction showed that structure apatite initially appeared at 300°C. The crystal size and the HA content increase with increasing calcination temperature. SEM analysis indicated the presence of pores that are important for biomedical applications, improving to the adhesion between neoformed bone tissue and synthesized apatite, i.e, osseointegration.

Scientific Electronic Library Online (Portuguese)

73

Estudo qualitativo fotoelástico do sistema de forças gerado pela mola "T" de retração com diferentes pré-ativações/ Qualitative photoelastic study of the force system produced by retraction T-springs with different preactivations

Maia, Luiz Guilherme Martins; Gomes, Vanderlei Luiz; Santos-Pinto, Ary dos; Lopes Júnior, Itamar; Gandini Jr., Luiz Gonzaga
2010-08-01

Resumo em português OBJETIVO: avaliar o sistema de forças gerado pela mola T utilizada para fechamento de espaços. MÉTODOS: por meio do método experimental fotoelástico, avaliou-se a mola T utilizada no fechamento de espaços com duas variações de pré-ativação em sua porção apical, sendo uma com 30º e a outra com 45º. As molas foram confeccionadas com fio retangular de titânio-molibdênio (TMA) de secção 0,017" x 0,025", centralizadas no espaço interbraquetes de 27mm e ativ (mais) adas em 5,0mm, 2,5mm e posição neutra. Para melhor confiabilidade dos resultados, os testes foram repetidos em três modelos fotoelásticos igualmente reproduzidos e confeccionados pelo mesmo operador. Para compreensão dos resultados, as franjas fotoelásticas visualizadas no polariscópio foram fotografadas e analisadas qualitativamente. RESULTADOS: por meio da análise qualitativa da ordem de franjas no modelo fotoelástico, notou-se que, nas extremidades de retração e ancoragem, a mola T com 30º de ativação apical apresentou um acúmulo de energia discretamente maior para o sistema de forças liberado. Resumo em inglês OBJECTIVE: Evaluate the force system produced by the T-spring used for space closure. METHODS: By means of the experimental photoelastic method, we evaluated the T-spring-used for space closure-with two different preactivations on its apical portion, i.e., one with 30° and one with 45º. The springs were fabricated with rectangular 0.017 X 0.025-in titanium-molybdenum alloy (TMA), centered in a 27.0 mm interbracket space and activated at 5.0 mm and 2.5 mm, and in a neutr (mais) al position. For more reliable results, tests were repeated on three photoelastic models duplicated and prepared by the same operator. To better understand the results, the fringes seen in the polariscope were photographed and analyzed qualitatively. RESULTS: Through qualitative analysis of the fringe order in the photoelastic model it was noted that at the retraction and anchoring ends the T-spring with 30° apical activation showed a slightly greater accumulation of energy relative to the force system that was generated.

Scientific Electronic Library Online (Portuguese)

74

Herniorrafia perineal, ressecção de cisto prostático e criptorquidectomia vídeolaparoscópicas por único acesso em cão/ Perineal vídeolaparoscopic, prostatic cystic resection, and cryptorchidectomy in a dog under unique access

Basso, Paula Cristina; Raiser, Alceu Gaspar; Brun, Maurício Veloso; Müller, Daniel Curvello de Mendonça; Trindade, Anelise Bonilla; Cavedon, Silvio Salles
2010-02-01

Resumo em português O presente relato descreve a realização de criptorquectomia, ressecção de cisto prostático e herniorrafia perineal vídeolaparoscópicas em um cão da raça Collie que apresentou recidiva dos sinais clínicos após redução cirúrgica convencional. Pela cirurgia laparoscópica, com três portais retroumbilicais, localizou-se um testículo intrabdominal, que foi removido após a aplicação de clipes de titânio no mesórquio e nos vasos testiculares. Verificou-se ta (mais) mbém a presença de um cisto prostático que foi drenado por punção transparietal com agulha e, em seguida, realizaram-se a ressecção da parede e omentopexia na cavidade cística. Na avaliação da cavidade pélvica, verificou-se que o tamanho do defeito herniário permitia ser manejado por laparoscopia. Aplicou-se uma sutura intracorpórea no padrão colchoeiro abrangendo músculo coccígeo e elevador do ânus. O procedimento total durou aproximadamente 140 minutos, não havendo complicações. Conclui-se que a cirurgia laparoscópica pode ser empregada no tratamento de cisto prostático e na herniorrafia perineal de cães. Resumo em inglês This research describes the cyst resection of the prostate, perineal hernia and laparoscopic criptorquidectomia of a Collie dog, which showed clinical signs of recurrence after conventional hernia surgery. By mean three retroumbilical portals,an intraabdominal testicle was located through laparoscopic surgery. It was removed after the application of titanium clips in mesorquio and pots testicules. A prostate cyst was noticed that was drained by puncture with a transpariet (mais) al needle. An incision was made in the wall and omentopexia of the cystic cavity was performed. In the evaluation of the pelvic cavity, it was found that the hernial defect was small and could be managed by laparoscopy. An intracorporeal suturing pattern was applied which covered the coccygeal muscle and lifted the anus. The entire procedure took about 140 minutes, with no complications. It was concluded that laparoscopic surgery can be used to treat prostate cysts and the perineal hernia of dogs.

Scientific Electronic Library Online (Portuguese)

75

Influência de argilas pilarizadas na decomposição catalítica do óleo de andiroba/ Influence of pillared clays in the catalitic decomposition of the andiroba oil

Guerra, D. L.; Lemos, V. P.; Angélica, R. S.; Airoldi, C.
2007-01-01

Resumo em português Amostras de esmectitas oriundas do estado do Pará, região amazônica, Brasil, foram usadas em processo de pilarização no presente estudo. As matrizes pilarizadas e natural foram caracterizadas usando DRX e analise textural usando isotermas de adsorção-desorção de nitrogênio. Os íons de intercalação (Al13, Ti, Zr) foram obtidos através de reações químicas com soluções de AlCl(3)6H2O/ NaOH, etoxido de titânio/HCl, acetato de zircônio / HCl. Os resultados (mais) obtidos com o processo de pilarização apresentaram aumento do espaçamento basal de 15,6 para 20, 64 Å e área superficial de 44 para 358 m²/g (Zr-PILC). A estabilidade térmica da argila natural foi melhorada com o processo de pilarização. O material resultante foi submetido a um processo catalítico de decomposição do óleo de andiroba em um reator de leito fixo a 673 ± 1 K. A atividade catalítica foi determinada pelo produto de decomposição resultante da reação química. Os parâmetros físico-químicos foram obtidos usando DRX, FTIR e análise textural. As argilas pilarizadas apresentaram alta acidez de Brønsted, com alta concentração de hidrocarbonetos aromáticos e baixa concentração de hidrocarbonetos alifáticos. Resumo em inglês Smectite-bearing clay samples from Pará state, Amazon region, Brazil, were used for pillaring process in the present study. The natural and pillarized matrices were characterized using XRD and textural analysis using nitrogen adsorption-desorption isotherms. The ions of intercalation (Al13, Ti, Zr) were obtained through chemical reactions of AlCl(3)6H2O/ NaOH, titanium ethoxide /HCl, zirconium acetate /HCl solutions. The Results showed that the pillarization process incr (mais) eases the basal spacing of the natural clay from 15.6 to 20.64 Å and the superficial area from 44 to 358 m²/g (Zr-PILC). The thermal stability of the natural clay was improved by the pillaring procedure. The resulting materials were submitted to catalytic process of decomposition of andiroba oil in a fix bed reactor at 673 ± 1 K. The catalytic activity was determined by the product composition resulting from the chemical reactions. The physicochemical parameters of the catalysts were obtained using XRD, FTIR and textural analysis. The pillared clays showed higher Brønsted acidity, with higher concentration in aromatic hydrocarbons and small concentration of aliphatic hydrocarbons.

Scientific Electronic Library Online (Portuguese)

76

Análise de falhas de implantes cirúrgicos no Brasil: a necessidade de uma regulamentação adequada/ Retrieval and failure analysis of surgical implants in Brazil: the need for proper regulation

Azevedo, Cesar R. de Farias; Hippert Jr., Eduardo
2002-10-01

Resumo em português Este artigo apresenta alguns casos de análise metalúrgica de falhas de implantes cirúrgicos metálicos utilizados no Brasil. Investigaram-se as causas das falhas de duas placas de compressão de aço inoxidável, uma placa-lâmina de aço inoxidável, uma placa de reconstrução de maxilar de liga de Ti com 6% de alumínio e 4% de vanádio (Ti-6Al-4V) e cinco arames de Nitinol (liga níquel-titânio). Adicionalmente, investigou-se a conformidade destes materiais às es (mais) pecificações técnicas da norma ABNT (Associação Brasileira de Normas Técnica). A investigação revelou que todos os implantes analisados não estavam de acordo com os requisitos mínimos da ABNT/ISO, e que as fraturas prematuras ocorreram por mecanismos assistidos por corrosão e/ou pela presença de defeitos (de fabricação, montagem ou de manuseio). Dados de literatura indicam que implantes de materiais não biocompatíveis podem causar diversos tipos de reações adversas no corpo humano, além de promover a falha prematura do componente e causar danos para o paciente e prejuízos para o investimento público. Não há no Brasil legislação sanitária que tornem compulsórios os procedimentos de notificação e de investigação dos casos de falhas de implantes cirúrgicos. Resumo em inglês This paper summarizes several cases of metallurgical failure analysis of surgical implants conducted at the Laboratory of Failure Analysis, Instituto de Pesquisas Tecnológicas (IPT), in Brazil. Failures with two stainless steel femoral compression plates, one stainless steel femoral nail plate, one Ti-6Al-4V alloy maxillary reconstruction plate, and five Nitinol wires were investigated. The results showed that the implants were not in accordance with ISO standards and pr (mais) esented evidence of corrosion-assisted fracture. Furthermore, some of the implants presented manufacturing/processing defects which also contributed to their premature failure. Implantation of materials that are not biocompatible may cause several types of adverse effects in the human body and lead to premature implant failure. A review of prevailing health legislation is needed in Brazil, along with the adoption of regulatory mechanisms to assure the quality of surgical implants on the market, providing for compulsory procedures in the reporting and investigation of surgical implants which have failed in service.

Scientific Electronic Library Online (Portuguese)

77

Análise de falhas de implantes cirúrgicos no Brasil: a necessidade de uma regulamentação adequada/ Retrieval and failure analysis of surgical implants in Brazil: the need for proper regulation

Azevedo, Cesar R. de Farias; Hippert Jr., Eduardo
2002-10-01

Resumo em português Este artigo apresenta alguns casos de análise metalúrgica de falhas de implantes cirúrgicos metálicos utilizados no Brasil. Investigaram-se as causas das falhas de duas placas de compressão de aço inoxidável, uma placa-lâmina de aço inoxidável, uma placa de reconstrução de maxilar de liga de Ti com 6% de alumínio e 4% de vanádio (Ti-6Al-4V) e cinco arames de Nitinol (liga níquel-titânio). Adicionalmente, investigou-se a conformidade destes materiais às es (mais) pecificações técnicas da norma ABNT (Associação Brasileira de Normas Técnica). A investigação revelou que todos os implantes analisados não estavam de acordo com os requisitos mínimos da ABNT/ISO, e que as fraturas prematuras ocorreram por mecanismos assistidos por corrosão e/ou pela presença de defeitos (de fabricação, montagem ou de manuseio). Dados de literatura indicam que implantes de materiais não biocompatíveis podem causar diversos tipos de reações adversas no corpo humano, além de promover a falha prematura do componente e causar danos para o paciente e prejuízos para o investimento público. Não há no Brasil legislação sanitária que tornem compulsórios os procedimentos de notificação e de investigação dos casos de falhas de implantes cirúrgicos. Resumo em inglês This paper summarizes several cases of metallurgical failure analysis of surgical implants conducted at the Laboratory of Failure Analysis, Instituto de Pesquisas Tecnológicas (IPT), in Brazil. Failures with two stainless steel femoral compression plates, one stainless steel femoral nail plate, one Ti-6Al-4V alloy maxillary reconstruction plate, and five Nitinol wires were investigated. The results showed that the implants were not in accordance with ISO standards and pr (mais) esented evidence of corrosion-assisted fracture. Furthermore, some of the implants presented manufacturing/processing defects which also contributed to their premature failure. Implantation of materials that are not biocompatible may cause several types of adverse effects in the human body and lead to premature implant failure. A review of prevailing health legislation is needed in Brazil, along with the adoption of regulatory mechanisms to assure the quality of surgical implants on the market, providing for compulsory procedures in the reporting and investigation of surgical implants which have failed in service.

Scientific Electronic Library Online (Portuguese)

78

Ameloblastoma mandibular tratado por ressecção óssea e reconstrução imediata/ Mandibular ameloblastoma treated by bone resection and imediate reconstruction

Montoro, José Raphael de Moura Campos; Tavares, Marconi Gonzaga; Melo, Daniel Hardy; Franco, Rosemeire de Lordo; Mello-Filho, Francisco Veríssimo de; Xavier, Samuel Porfírio; Trivellato, Alexandre Elias; Lucas, André Silva
2008-02-01

Resumo em português O ameloblastoma multicístico acomete principalmente pacientes adultos, entre a terceira e a sétima década de vida, freqüentemente na região posterior de mandíbula. A ressecção de um segmento mandibular, sem reconstrução adequada, produz grave seqüela estética e funcional levando a uma perda da qualidade de vida. O objetivo desta apresentação é mostrar que o tratamento multidisciplinar do ameloblastoma possibilita radicalidade oncológica associada à comple (mais) ta reconstrução da área lesada. Apresentamos um paciente de 47 anos, acometido por um ameloblastoma em região posterior de mandíbula tratado com ressecção completa de um segmento mandibular. A reconstrução no mesmo tempo operatório utilizou enxerto ósseo de crista ilíaca fixado com placas e parafusos de titânio. Após oito meses completou-se a reabilitação com implantes de elementos dentários na área do enxerto. As vantagens deste procedimento incluem a diminuição do risco de recidivas pelo uso da ressecção segmentar, reconstrução mandibular confiável e diminuição do número de procedimentos cirúrgicos, permitindo completa reabilitação em um período mais curto de tempo. Resumo em inglês Multicystic ameloblastoma mainly affects adult patients between the third and seventh decades of life, frequently in the posterior region of the mandible. The resection of a mandible segment without adequate reconstruction produces serious esthetic and functional sequelae leading to a loss of quality of life. The objective of this study is to show that multidisciplinary treatment of ameloblastomas helps in total lesion excision associated with complete reconstruction of t (mais) he damaged area. We present a 47-year-old male patient with an ameloblastoma in the posterior mandible who was treated with complete resection of a mandibular segment. Reconstruction, carried out during the same surgical procedure, was performed using an iliac crest bone graft fixed with titanium plates and screws. Rehabilitation was completed eight months later with teeth implants in the grafted area. The advantages of this procedure include recurrence risk reduction due to segmental resection, reliable mandibular reconstruction and less surgical procedures, allowing full rehabilitation within a shorter period of time.

Scientific Electronic Library Online (Portuguese)

79

Modelo experimental de reconstrução em falha mandibular em coelhos/ Experimental model of reconstruction in mandibular defect in rabbit

Gomes, Cristiano; Elizeire, Mariane Brascher; Becker, Paula; Foerstnow, Lisiane; Stein, Gisele; Alievi, Marcelo Meller; Cirne-Lima, Elizabeth Obino; Contesini, Emerson Antonio
2010-07-01

Resumo em português Este trabalho tem como objetivo apresentar um novo modelo experimental de reconstrução em falha mandibular em coelhos. Foram utilizados 14 animais, nos quais, em uma primeira etapa, extraiu-se cirurgicamente o dente incisivo inferior esquerdo permanente. Após um período de 50 dias para o preenchimento ósseo do alvéolo dentário, foi realizada a cirurgia. Inicialmente, coletou-se 10x5x5mm de enxerto ósseo autógeno da crista ilíaca e, em seguida, foi procedida uma (mais) falha mandibular parcial de mesmo tamanho, que foi preenchida com o enxerto e fixada com microplaca de titânio. Os coelhos foram submetidos a avaliações clínicas e radiográficas, sendo sete submetidos a eutanásia aos 15 dias e os demais aos 30 dias para análise macro e microscópica. A ingestão de água e ração não foi comprometida, e os animais não apresentaram algia, dificuldade de mastigação e de apreensão. Somente um animal apresentou rejeição a um parafuso, sem ocorrer o deslocamento da placa nem do enxerto. Esse método mostrou-se eficaz como modelo experimental de reconstrução em falha mandibular de coelhos, demonstrando a evolução cicatricial óssea do enxerto por meio dos exames radiográficos, macroscópicos e microscópicos aos 15 e 30 dias. Resumo em inglês This paper aims to present a new experimental model of mandibular defect reconstruction in rabbits. It was used 14 animals, in which, in a first stage the left permanent inferior incisive tooth was extracted surgically. After a 50 days period for the bone to fulfill the dentary alveolus, surgery was performed. At first, a 10x5x5mm autograft was removed form the iliac crest, following a partial mandibular failure in the bone with the same auto graft size which was filled w (mais) ith the graft and fixed using titanium microplate. The rabbits were submitted to clinical and radiographic evaluation and 7 of them were euthanasiated at 15 days and the other 7 at 30 days to macro and microscopic analysis. The water and commercial food ingestion was not compromised, and the animals did not showed any chewing or apprehension difficulties, neither pain. Only one animal presented rejection to one screw, without occurring micro plate nor auto graft dislocation. This method showed to be efficient for an experimental model of reconstruction in mandibular defects of rabbits, demonstrating a healing evolution of the graft through radiographic, macroscopic and microscopic exams in 15th and 30th days.

Scientific Electronic Library Online (Portuguese)

80

Análise dosimétrica de acompanhantes de pacientes de medicina nuclear internados em quarto terapêutico/ Dosimetric analysis of persons accompanying nuclear medicine patients in the therapeutic room

Oliveira, Jetro Pereira de; Lopes, Márcia Maria dos Santos; Rosa, Luiz Antonio Ribeiro da; Fonseca, Léa Mirian Barbosa da; Corbo, Rossana
2008-02-01

Resumo em português OBJETIVO: Este trabalho avaliou doses recebidas por acompanhantes que compartilharam o mesmo quarto terapêutico com pacientes tratados com câncer de tireóide ingerindo iodo-131 (131I) e comparou os resultados obtidos aos limites determinados pelas normas brasileiras de radioproteção. MATERIAIS E MÉTODOS: Avaliaram-se seis grupos de pessoas. Cada grupo foi formado por um acompanhante e um paciente, que compartilharam o mesmo quarto terapêutico. Realizaram-se, també (mais) m, 23 outros experimentos, sendo que nestes um simulador foi usado em substituição à segunda pessoa no quarto terapêutico. As atividades de 131I administradas aos pacientes foram de 3.700 MBq ou 5.550 MBq. Dosímetros termoluminescentes na forma de pó, fluoreto de lítio dopado com magnésio, titânio e sódio foram usados para a avaliação das doses. RESULTADOS: Os resultados mostraram que uma pessoa que compartilha o mesmo quarto terapêutico, durante dois dias, com um paciente tratado com 3.700 MBq ou 5.550 MBq de 131I, seguindo as orientações de radioproteção fornecidas pela equipe médica, é exposta a uma dose média de (0,51 ± 0,02) mSv, para um nível de confiança de 99%. CONCLUSÃO: De acordo com as normas brasileiras, do ponto de vista da radioproteção, não há impedimento acompanhar um paciente de medicina nuclear durante esse tratamento. Resumo em inglês OBJECTIVE: The present study evaluated the doses received by companions who had shared therapeutic rooms with patients undergoing treatment with 131-iodine (131I). The results were compared with the limits established by the Brazilian radiation protection regulatory standard. MATERIALS AND METHODS: Six pairs of persons (a patient and a companion sharing a same therapeutic room) were evaluated. Still, other 23 experiments were accomplished with a phantom replacing the comp (mais) anion. The therapeutic 131I activities given to the patients corresponded to 3700 MBq or 5550 MBq. Powdered lithium fluoride thermoluminescent dosimeters doped with magnesium, titanium and sodium were utilized for evaluating the doses. RESULTS: The results demonstrate that a person sharing a same therapeutic room, for two days, with a patient who had been given 3700 MBq or 5550 MBq of 131I, according to radioprotection recommendations, is exposed to a mean dose of (0.51 ± 0.02) mSv for a 99% confidence level. CONCLUSION: According to the Brazilian radiation protection standards there is no impediment for a person to accompany a nuclear medicine patient who has been given 3700 MBq or 5550 MBq of 131I during the patient stay in the therapeutic room.

Scientific Electronic Library Online (Portuguese)

81

Simulação computacional de um feixe de fótons de 6 MV em diferentes meios heterogêneos utilizando o código PENELOPE/ Computer simulation of a 6 MV photon beam in different heterogeneous media utilizing the PENELOPE code

Salata, Camila; Sibata, Claudio Hissao; Ferreira, Nadya Maria; Almeida, Carlos Eduardo de
2009-08-01

Resumo em português OBJETIVO: Utilizar o código PENELOPE e desenvolver geometrias onde estão presentes heterogeneidades para simular o comportamento do feixe de fótons nessas condições. MATERIAIS E MÉTODOS: Foram feitas simulações do comportamento da radiação ionizante para o caso homogêneo, apenas água, e para os casos heterogêneos, com diferentes materiais. Consideraram-se geometrias cúbicas para os fantomas e geometrias em forma de paralelepípedos para as heterogeneidades c (mais) om a seguinte composição: tecido simulador de osso e pulmão, seguindo recomendações da International Commission on Radiological Protection, e titânio, alumínio e prata. Definiram-se, como parâmetros de entrada: a energia e o tipo de partícula da fonte, 6 MV de fótons; a distância fonte-superfície de 100 cm; e o campo de radiação de 10x 10 cm². RESULTADOS: Obtiveram-se curvas de percentual de dose em profundidade para todos os casos. Observou-se que em materiais com densidade eletrônica alta, como a prata, a dose absorvida é maior em relação à dose absorvida no fantoma homogêneo, enquanto no tecido simulador de pulmão a dose é menor. CONCLUSÃO: Os resultados obtidos demonstram a importância de se considerar heterogeneidades nos algoritmos dos sistemas de planejamento usados no cálculo da distribuição de dose nos pacientes, evitando-se sub ou superdosagem dos tecidos próximos às heterogeneidades. Resumo em inglês OBJECTIVE: The PENELOPE code was utilized to simulate irradiation geometries where heterogeneities are present and to simulate a photon beam behavior under these conditions. MATERIALS AND METHODS: For the homogeneous case, the ionizing radiation behavior was simulated only with water, and different materials were introduced to simulate heterogeneous conditions. Cubic geometries were utilized for the homogeneous phantoms, and parallelepiped-shaped geometries for the hetero (mais) geneities with the following composition: bone and lung tissue simulators, as recommended by the International Commission on Radiological Protection, and titanium, aluminum and silver. Input parameters were defined as follows: energy and type of source, 6 MV photons; source-surface distance=100 cm; and radiation field of 10x 10 cm². RESULTS: Percentage depth-dose curves were obtained for all the cases. As result, it was observed that for high electronic density materials, such as silver, the absorbed dose is higher than the absorbed dose in the homogeneous phantom, and for the lung tissue simulator, it is lower. CONCLUSION: Results clearly demonstrate the relevant role of heterogeneities in the treatment planning system algorithms utilized in the calculation of dose distribution in patients, increasing the accuracy of the dose delivered to the tumor and avoiding unnecessary irradiation of healthy tissues.

Scientific Electronic Library Online (Portuguese)

82

Ovário-histerectomia em caninos por cirurgia laparoscópica/ Laparoscopic ovariohysterectomy in canine

BRUN, Maurício Veloso; SILVA FILHO, Antônio de Pádua Ferreira da; BECK, Carlos Afonso de Castro; MARIANO, Mirandolino Batista; MELLO, João Roberto Braga de
2000-12-01

Resumo em português Neste estudo, foram realizadas ovário-histerectomias laparoscópicas em 24 caninos. Os procedimentos cirúrgicos foram realizados sob anestesia geral, com os animais em decúbito dorsal. A cavidade abdominal foi puncionada com a agulha de Veress e foi insuflada com CO2. Os animais foram então colocados em posição de Trendelenburg, e quatro trocartes foram introduzidos em diferentes regiões da parede abdominal. Após a identificação do útero, os vasos uterinos fora (mais) m isolados e ligados com dois clipes de titânio. O corpo do útero foi seccionado cranialmente à cérvix. A bursa ovariana foi exposta, e o ligamento suspensor foi apreendido com uma pinça. Procedeu-se à aplicação de um clipe neste ligamento previamente a sua secção. O complexo arteriovenoso ovariano foi ligado com um clipe e depois foi seccionado em conjunto com o mesovário. O ligamento redondo e o mesométrio foram seccionados com tesoura e cauterização monopolar. O útero e ambos os ovários foram retirados em bloco da cavidade por uma das incisões existentes. A principal complicação transoperatória foi a ocorrência de hemorragia, que ocasionou um óbito e uma conversão para cirurgia aberta. Na maioria dos animais, esta complicação foi adequadamente controlada pela aplicação de clipes e/ou utilização de cauterização monopolar. A realização de ovário-histerectomia em caninos por cirurgia laparoscópica demonstrou ser viável, e a técnica descrita para este procedimento mostrou-se adequada. Resumo em inglês Twenty-four female canine subjects were submitted to ovariohysterectomies through laparoscopic surgical procedures. The surgical procedures were performed under general anesthesia with the animals in dorsal recumbency. The abdominal cavity was accessed through a punction with a Veress needle and was inflated with CO2. The animal was then placed in Trendelemburg position and four trocars were inserted in different regions of the abdominal wall. Following uterus identificat (mais) ion, blood vessels were isolated and clipped with metallic devices. The body of the uterus was cut cranial to the cervix. The ovarian bursa was exposed and the suspensor ligament was fixed with a nipper. The suspensor ligament was clipped previously to its section. The ovarian arterial-venous complex was clipped and cut with the mesovarium ligament. The round ligament and the mesometrium were cut with a scissors and cauterized. The uterus and both ovaries were removed from the abdominal cavity trough one of the incisions. The most important intra-operatory event was the presence of hemorrhage with one death and one conversion to celiotomy. In the majority of the animals the hemorrhage was controlled with the placement of clips and/or cauterization. The laparoscopic surgery showed to be a suitable technique to perform ovariohysterectomy in canine females.

Scientific Electronic Library Online (Portuguese)

83

Avaliação da técnica de epifisiodese temporária com o uso das placas de Sherman: resultados preliminares/ Evaluation of the temporary epiphysiodesis procedure using the sherman plate: preliminary results

Pinto, José Antonio; Christiano, Eduardo Suñe; Sanchez, Gustavo Tadeu; Blumetti, Francesco Camara; Dobashi, Eiffel Tsuyoshi; Pinto, Bruno Luis Moraes
2010-12-01

Resumo em português OBJETIVO: Avaliar os resultados preliminares da técnica de epifisiodese temporária utilizando-se as placas de Sherman no tratamento de distúrbios e deformidades dos membros inferiores. MÉTODOS: Foram avaliados, retrospectivamente, 27 pacientes submetidos à epifisiodese temporária do fêmur distal ou tíbia proximal com as placas de Sherman, em um total de 28 procedimentos. A idade média no momento da cirurgia foi de 11,2 anos (3-15 anos). Os implantes de dois furos (mais) eram confeccionados em liga de aço e apresentavam um orifício central para ser utilizado como guia. A fixação foi feita com dois parafusos canulados de 3,5mm. As indicações para o tratamento foram os desvios angulares dos membros inferiores em valgo (n = 10), varo (n = 2) e mistos (n = 1); discrepância do comprimento dos membros (n = 9); e contratura em flexo do joelho (n = 5). RESULTADOS: O tempo médio de seguimento foi de 11,78 meses (±4,07). Observamos apenas um evento adverso (migração do implante) em um paciente submetido à epifisiodese anterior do fêmur distal para correção de flexo de joelho. Não houve nenhum caso de quebra do material ou fechamento fisário prematuro. CONCLUSÃO: A técnica de epifisiodese temporária com o uso das placas de Sherman mostrou ser de fácil execução e esteve envolvida com um baixo índice de complicações e custo inferior aos implantes similares em titânio. Por ser um procedimento de baixa morbidade, pode ser indicado em uma ampla faixa etária e para uma grande variedade de distúrbios do esqueleto imaturo. Resumo em inglês OBJECTIVE: To evaluate the preliminary results of a technique using temporary epiphysiodesis plates using a Sherman plate in the treatment of disorders and deformities of the lower limbs. METHODS: We retrospectively reviewed 27 patients who underwent temporary epiphysiodesis of the distal femur or proximal tibia with Sherman plates, comprising 28 procedures. The mean age at surgery was 11.2 years (3-15 years). The two-hole plates were made of steel alloy and had a central (mais) hole to be used as a guide. The fixation was performed with two 3.5 mm cannulated screws. Indications for treatment were the angular deviations of the lower limbs in valgus (n = 10), varus (n = 2) and mixed (n = 1), limb length discrepancy (n = 9), and the flexion contracture of the knee (n = 5). RESULTS: The mean follow-up period was 11.78 months (± 4.07). We observed only one adverse event (migration of the implant) in a patient who underwent anterior epiphysiodesis of the distal femur for the correction of knee flexion. There were no cases of equipment failure or premature physeal closure. CONCLUSION: The temporary epiphysiodesis procedure using the Sherman plates proved to be easy to execute and was involved with a low rate of complications and lower cost than similar titanium implants. Because it is a procedure with low morbidity, this surgical technique may be indicated for a wide age range and for a variety of disorders of the immature skeleton.

Scientific Electronic Library Online (Portuguese)

84

Análise da microestrutura e da resistência ao desgaste de revestimento duro utilizado pela indústria sucroalcooleira/ Analysis of microstructure and wear strength of hardfacing used by the sugar and alcohol industry

Lima, Aldemi Coelho; Ferraresi, Valtair Antonio
2009-06-01

Resumo em português O setor sucroalcooleiro tem apresentado um expressivo crescimento nos últimos anos no Brasil, entretanto, a manutenção das indústrias apresenta um elevado custo devido à perda de metal dos equipamentos por mecanismos de desgaste. O objetivo deste trabalho é avaliar a resistência ao desgaste abrasivo e a microestrutura de revestimentos duros depositados em camada única. Foram utilizados quatro tipos de consumíveis utilizados na indústria sucroalcooleira: um eletr (mais) odo revestido da liga FeCrC de 4,0 mm de diâmetro e três arames tubulares autoprotegidos de 1,6 mm de diâmetro, de ligas FeCrC, FeCrCNb, FeCrCTiMo. O metal de base utilizado foi um aço SAE 1020. As soldagens com os arames tubulares foram efetuadas no modo de transferência por curto-circuito, com mesmos valores de corrente e tensão de soldagem. Para o ensaio de desgaste utilizou-se o abrasômetro Roda de Borracha, segundo a norma ASTM G65-91. Os corpos de prova de desgaste foram retirados da região central das chapas de testes e da mesma região retirou-se dois conjuntos de amostras para análise microestrutural (microscopia ótica). Os resultados dos ensaios com a roda de borracha mostrou que a liga FeCrCNb apresenta maior resistência ao desgaste, seguida do eletrodo revestido e com pior desempenho a liga FeCrCMoTi e a liga FeCrC. A liga FeCrC (tanto para o eletrodo revestido como para o arame tubular) apresentou microestrutura formada por carbonetos primários M7C3 distribuídos em uma matriz de menor dureza; a liga contendo Nb apresentou microestrutura similar além da presença de carbonetos NbC; por sua vez, a liga com adição de Ti e Mo apresentou a presença de grandes carbonetos primários de titânio. Resumo em inglês The Brazilian sugar/alcohol sector presented expressive growth in recent years. However, maintenance cost is high due to metallic losses by wear. This paper studies the application of hardfacing by flux cored arc welding on the wear resistance and microstructure of single layer weld beads. Four types of consumable were used: three selfshielded flux cored wires of 1.6 mm diameter of alloys FeCrC, FeCrCNb, FeCrCMoTi and a covered electrode of FeCrC alloy of 4 mm diameter. T (mais) he base metal was SAE 1020 steel. Test specimens were evaluated using Rubber Wheel Abrasion Test (ASTM G65). The selfshielded flux cored wires were welded in short-circuit transfer mode with the same current and voltage values. Wear evaluation was by mass loss and microstructure analysis by optic microscopy. The results of the trials with Rubber Wheel Test showed that the FeCrCNb alloy presented the largest wear resistance, followed by the covered electrode. The FeCrC+Ti alloy and the FeCrC alloy presented the worst performance. The FeCrC alloy (for both covered electrode and tubular wire) presented microstructure formatted by primary M7C3 carbides distributed in a smaller hardness matrix; the alloy containing Nb presented a similar microstructure apart from its carbides that were mainly NbC. The alloy with Ti and Mo addition presented large titanium primary carbides.

Scientific Electronic Library Online (Portuguese)

85

Controle dos vasos renais usando clips vasculares e fio cirúrgico em nefrectomias vídeo-assistidas de doadores vivos/ Control of renal vessels using titanium clips and cotton suture in hand-assisted laparoscopic live donor nephrectomy

Branco Filho, Alcides José; Branco, Anibal Wood; Kondo, William; Maciel, Rafael Fabio; Carvalho, Ronaldo Moreno de; Garcia, Mariana Jorge
2005-02-01

Resumo em português OBJETIVO: A nefrectomia laparoscópica em doadores vivos para transplante renal vem assumindo um papel importante na era das cirurgias minimamente invasivas, acarretando menor morbidade aos doadores, e resultados semelhantes à técnica aberta no que se refere ao enxerto renal. O objetivo do presente artigo é relatar a experiência do nosso serviço utilizando a técnica de controle dos vasos renais usando fio cirúrgico e clips vasculares. MÉTODO: Foram realizadas 45 n (mais) efrectomias utilizando a técnica vídeo-assistida, com ligadura dos vasos renais com clips de titânio (LT-300) e fio cirúrgico. As variáveis analisadas foram tempo cirúrgico, perda sangüínea, tempo de isquemia quente, permanência hospitalar, necessidade de conversão e complicações. RESULTADOS: O procedimento foi realizado com sucesso em todos os casos. O tempo cirúrgico médio foi de 118 minutos, com perda sangüínea estimada em 84ml e tempo de isquemia quente de 4,3 minutos. Dois casos de íleo prolongado, uma lesão de veia gonadal, um escape de artéria renal e uma necrose de ureter foram observados. A permanência hospitalar média foi de 3,7 dias. O uso de clips vasculares e fio cirúrgico reduziu a perda de tecido venoso comparado à técnica com staplers e gerou redução de custos. CONCLUSÕES: A nefrectomia vídeo-assistida com a técnica descrita é factível e mostrou ser efetiva na contenção de gastos e na redução de tecido venoso perdido. Resumo em inglês BACKGROUND: Laparoscopic live donor nephrectomy has acquired an important role in the minimally invasive surgery era, decreasing morbidity to kidney donors, with an equivalent renal graft outcome compared with open surgery. The aim of this article is report our experience using the technique of renal vessels control with metallic clips and cotton suture. METHODS: Fourty-five nephrectomies were performed following the hand-assisted technique and using titanium clips (LT-30 (mais) 0) and cotton suture for renal vessels ligatures. Operative data and postoperative courses were reviewed, including surgical time, estimated blood loss, warm ischemia time, length of hospital stay, conversion to laparotomy, and complications. RESULTS: The procedure was performed successfully in all cases, including 18 right nephrectomies and 27 left nephrectomies. The mean operative time in our series was 118 minutes, with an estimated blood loss of 84ml and warm ischemia time of 4.3 minutes. Two cases of postoperative ileus, one gonadal vein lesion, one metallic clip displacement and one ureteral necrosis were observed. The mean postoperative hospital stay was 3.7 days. The use of titanium clips and cotton suture reduced the loss of venous tissue compared to the technique using the Endo-GIA stapling device (4 to 6 mm vs. 10 to 15 mm) and showed to be associated with a cost reduction, saving about 700 US dollars per stapler. CONCLUSION: Hand-assisted nephrectomy using the above described technique is technically feasible and showed to be effective in reducing costs and decreasing the loss of vascular length.

Scientific Electronic Library Online (Portuguese)

86

Cirurgia das fraturas do seio frontal: estudo epidemiológico e análise de técnicas/ Surgery of frontal sinus fractures: epidemiologic study and evaluation of techniques

Montovani, Jair Cortez; Nogueira, Emanuel Araújo; Ferreira, Fabricio Dominici; Lima Neto, Arlindo Cardoso; Nakajima, Victor
2006-04-01

Resumo em português O trauma do seio frontal não é raro, correspondendo a 8% das fraturas faciais. Pode afetar a lâmina anterior e/ou posterior, com ou sem envolvimento do ducto nasofrontal. Tem alto potencial para complicações e seu manejo ainda é controvertido em algumas situações. OBJETIVO: Apresentar a epidemiologia, o diagnóstico e tratamento clínico e cirúrgico de 24 pacientes com fratura do seio frontal. MATERIAL E MÉTODOS: Estudo retrospectivo, não randomizado, de 24 pac (mais) ientes com fratura de seio frontal operados no Hospital das Clínicas da Faculdade de Medicina de Botucatu, São Paulo, Brasil. RESULTADOS: Dos 24 pacientes, 16 tinham fraturas da lâmina externa e 8, da lâmina interna e externa. Em 2 casos havia lesão do ducto nasofrontal. Vinte (83,4%) pacientes tiveram fraturas faciais associadas e em 13 (54,2%) foram observadas complicações intracranianas. A incisão em asa de borboleta, abaixo da sobrancelha, foi empregada na maioria dos casos cirúrgicos com bom resultado estético. Fixação dos fragmentos ósseos com diferentes materiais (fio de aço, mononylon, miniplacas de titânio) e, se necessário, reconstrução da tábua anterior com material aloplástico ou osso parietal. CONCLUSÃO: A causa principal das fraturas do seio frontal é acidente com veículos. O tratamento depende de sua complexidade, pois comumente há lesões cranioencefálicas associadas. As técnicas cirúrgicas utilizadas são as incisões, retalho bicoronal ou na sobrancelha, infra-orbital (em asa de borboleta), associadas à cirurgia endoscópica em casos de infecção fístula liquórica e complicações orbitárias. Resumo em inglês The frontal sinus trauma is not rare and it is 8% of the facial fractures. It can affect the anterior and/or posterior plates, with or without hitting the nasofrontal duct. It has a large potential of complications and its management still being a controversy. OBJECTIVE: To present the casuistic of fractures frontal sinus, the epidemiology and clinical and surgical management of frontal sinus fractures. MATERIALS AND METHODS: Not randomized retrospective study of 24 patie (mais) nts with frontal sinus fractures Hospital of Clinics, School of Medicine Botucatu, São Paulo, Brazil. RESULTS: From the 24 patients, we had 16 (66,6%) fractures of the extern plate and 8 (33,4%) of both. In 2 patients the nasofrontal duct was involved. Others facial fractures were associated in 20 (83,4%) cases and major lesions of the cerebral segment were found in 13 (54,2%). Subpalpebral incision was performed in the majority with satisfactory aesthetic results. The basis of the surgical treatment was reduction and fixation with different materials (steel wire, mononylon, titanium miniplates) and if necessary we used alogen implants or parietal bone to reconstruct the anterior plate. CONCLUSION: The principal cause of frontal sinus fractures is crashed car. The management depends of the complexity, because commonly there are cranioencephalic lesions associated. The surgical thecniques used are the incisions, bicoronal flap or brow-glabella, infra-orbital rim ("butterfly"), associated a endoscopy sinus surgery in cases of infection, cerobrospinal fluid leak and orbital complications.

Scientific Electronic Library Online (Portuguese)

87

Movimentação de molares inferiores ancorados em mini-parafusos/ Mandibular molar uprighting, using mini-screw as anchorage

Di Matteo, Rosana Canteras; Villa, Nelson; Sendyk, Wilson Roberto
2005-08-01

Resumo em português Freqüentemente a movimentação ortodôntica exige recursos adicionais de ancoragem. Os mini-parafusos têm-se apresentado como uma possível solução. O propósito deste trabalho foi estabelecer um método para a verticalização de molares inferiores inclinados para mesial, utilizando ancoragem em mini-parafusos colocados na região de linha oblíqüa externa da mandíbula. Foram selecionados três pacientes entre 40 a 48 anos (dois do gênero feminino, um do gênero (mais) masculino), com molares inferiores inclinados para mesial e distalmente posicionados às áreas edêntulas. Os pacientes foram tratados ortodonticamente durante um período de 6 a 12 meses, com técnica ortodôntica MD3. Mini-parafusos de titânio foram colocados bilateralmente com anestesia local. Uma incisão sobre a linha oblíqüa externa da mandíbula, medindo aproximadamente 1 cm foi realizada em cada lado, distalmente aos molares inclinados. Após descolamento muco-periosteal, mini-parafusos foram implantados e foram realizadas suturas deixando suas cabeças exteriorizadas. Uma semana após a remoção das suturas, cargas ortodônticas (entre 150 a 200 gramas/força) foram aplicadas através de forças elásticas. Verificamos que alguma inflamação foi observada ao redor dos mini-parafusos, mas foi controlada com procedimentos de higienização. O procedimento cirúrgico é simples, podendo ser realizado pelo ortodontista; as formas dimensionais dos mini-parafusos são adequadas e estes são de fácil remoção após uso. Concluímos que o uso de mini-parafusos representa uma alternativa efetiva de ancoragem ortodôntica na verticalização de molares inferiores. Resumo em inglês Tooth movement frequently requires additional anchorage resources. Mini-screws have been used as a possible solution to this matter. The purpose of this study was to establish a method of mandibular molar uprighting, using mini-screw as anchorage, positioned on the mandibular external oblique line, behind and posterior to the tooth. Three pacients with ages between 40 and 48 years old (two females and one male) were selected. The three of them presented mesially tipped mo (mais) lars, positioned posterior to the edentulous areas, on both sides of the mandible. These patients received orthodontic treatment during a period of 6 and 12 months with the MD3 technique. Titanium mini-screws were positioned bilaterally, under local anesthesia. One incision with 1 cm was done in each side of the mandibular external oblique line, distally to the tipped molars. After that, the mini-screws were positioned and sutures were done, leaving the mini-screws heads exposed. After one week, orthodontic loads (between 150 and 200 grams/force) were applied to the mini-screws through elastics. A certain degree of inflammation around the mini-screws was noticed, but it was controlled by hygienic procedure. This surgery procedure was simple and could be done easily by the orthodontist. The dimensions and shapes of the mini-screws proved to be appropriate and their removal after the orthodontic movement were done without difficulty. The result was time reduction on the molars uprighting, without side effects on the others teeth. The use of mini-screws seems to be a good alternative for an effective orthodontic anchorage on the uprighting mandibular molars.

Scientific Electronic Library Online (Portuguese)

88

Estudo inicial da degradação "in vivo" de poli(L-co-D,L ácido lático), sintetizado em laboratório, aplicado como prótese tibial em coelhos/ Initial study of in vivo degradation of poly(L-lactic acid-co-D,L ácid láctic), PLDLA

Motta, A.C.; Duek, E.A.R.
2009-01-01

Resumo em português O copolímero poli(L-co-D,L ácido lático), PLDLA, tem ganhado destaque no campo das próteses temporárias, em virtude de seu tempo de degradação ser bastante compatível com o requisitado no caso de fraturas ósseas. Neste trabalho estudou-se a degradação in vivo de dispositivos do copolímero PLDLA, na forma de um sistema de placas e parafusos, empregado na fixação interna da tíbia de coelhos. Os dispositivos foram implantados em 15 coelhos adultos, albinos, da (mais) raça Nova Zelândia. Foram utilizados como controle dispositivos a base de ligas de titânio. (Ti-6Al-4V/Grau V) A aplicação de copolímeros do poli (L-co-D, lácido lático), sintetizado em laboratório, foi testada no reparo de fratura em tíbias de coelhos, sendo avaliado nos seguintes tempos: 2 semanas, 2 meses e 3 meses. A análise morfológica do tecido circunjacente ao sistema placa e parafuso PLDLA, referente a 2 semanas do implante, mostra a presença de osteoblastos, indicando uma pré formação óssea. Após 2 meses verifica-se neoformação óssea na região em contato com o polímero. Esse crescimento ósseo ocorre simultaneamente ao processo de degradação do PLDLA, invadindo a região onde havia o polímero e após 3 meses verifica-se uma intensa degradação do copolímero PLDLA e conseqüentemente uma maior invasão tecidual comparado a 2 meses, sendo caracterizado uma formação óssea na região em que o polímero degradou. O estudo da degradação "in vivo" dos dispositivos de PLDLA, por meio das avaliações histológicas durante o período de consolidação da fratura, mostrou a eficiência deste sistema placa e parafuso, sendo possível verificar formação de tecido ósseo no local do implante, sem a presença de reação inflamatória. Resumo em inglês The copolymer poly (L-co-D,L lactic acid), PLDLA, has gained prominence in the field of temporary prostheses due to the fact that their time of degradation is quite compatible with the requirement in the case of osseous fracture. In this work the in vivo degradation of devices from copolymer, as a system of plates and screws, used in fixation of the tibia of rabbits was studied. The devices were implanted in 15 adult rabbits, albinos, New Zealand race, and they were used (mais) as control devices of alloys of titanium (Ti-6Al-4V/ V grade). The use of copolymers, synthesized in the laboratory, was tested in the repair of fracture in rabbits'tibias, being assessed in the following times: 2 weeks, 2 months and 3 months. Morphological analysis of tissue surrounding the plate and screw system, for 2 weeks of implantation, showed the presence of osteoblasts, indicating a pre bone formation. After 2 months there was new bone formation in the region in contact with the polymer. This bone growth occurred simultaneously with the process of PLDLA degradation, invading the region where there was polymer and after 3 months there was an intense degradation of the copolymer and hence greater tissue invasion compared to 2 months which characterized bone formation in a region where the polymer degraded. The in vivo degradation study of the devices for PLDLA by means of histological evaluations during the period of consolidation of the fracture showed the efficiency of plate and screw system, and it was possible to check formation of bone tissue at the implantation site, without the presence of inflammatory reaction

Scientific Electronic Library Online (Portuguese)

89

Metodologia para a aplicação da análise topográfica ao estudo de processos de superfície/ Methodology for application of the topographical analysis to the study of surface processes

Unda, Andrés G.R.; Lin, Vanessa F.C.; De Godoy, Geralda Cristina Durães
2007-12-01

Resumo em português A deposição de recobrimentos em uma superfície visa a melhoria de determinadas propriedades do material tais como as propriedades químicas e tribológicas. O desgaste pode ser minimizado seja pelo aumento da dureza da superfície seja pela diminuição da adesão entre as superfícies. Atualmente, ferramentas de corte são recobertas com TiN, TiCN e (TiAl)N, através de processos de deposição física a vapor, com o objetivo de aumentar a sua vida útil. Estes recobr (mais) imentos são caracterizados por uma alta dureza, excelente aderência, baixa porosidade, alta estabilidade química e térmica, entre outras características. As ferramentas de corte estão sujeitas a processos de degradação também por oxidação e corrosão. Nestes processos, a rugosidade da superfície tem um papel fundamental. O trabalho em questão objetiva o desenvolvimento de uma metodologia para aplicação de análise topográfica tridimensional (3D) ao estudo de processos de oxidação de recobrimentos e de superfícies. Neste estudo, realizou-se a oxidação do conjugado widea / nitreto de titânio e alumínio na faixa de temperaturas de 650ºC a 800ºC, para tempos de até 120 minutos. As amostras foram analisadas por perfilometria antes e após a oxidação. O resultado principal deste trabalho foi o desenvolvimento de uma metodologia de análise topográfica 3D, que pode ser aplicada ao estudo da superfície de materiais. A caracterização mais detalhada da topografia da superfície, usando-se diversos parâmetros além da medida usual de rugosidade, é de fundamental importância para a elucidação dos mecanismos atuantes nos processos de oxidação e corrosão dos materiais. Resumo em inglês Coating deposition on material surfaces improves properties of the material such as the chemical and tribological properties. The durability of the material can be maximized and the wearing away of the surface can be minimized either by increasing the hardness of the surface or by reducing adhesion on the surface of the material submitted to wear. At the present time, cutting tools are coated with TiN, TiCN and (TiAl)N, using physical vapor deposition, PVD, in order to in (mais) crease their useful life. These coatings are characterized by high degree of hardness, excellent adherence, low porosity, and a high chemical and thermal stability. The cutting tools are submitted to degradation processes of oxidation and corrosion. In these processes, the surface roughness plays an important role. This work objectifies the development of a methodology to apply a three-dimensional topographical analysis to the study of oxidation on coatings and surfaces. In this work, the oxidation of (TiAl)N coatings on widea substrate subjected to temperatures ranging from 650 ºC to 800 ºC was studied, for oxidation times up to 120 minutes. The samples were analyzed by profilometry before and after the oxidation. The principal result of this work was the development of a methodology of three-dimensional topographical analysis, which can be applied to study of the surface process of materials. The more rigorous characterization of the surface topography, using several parameters beyond the usual roughness measurements, is important to elucidate the operating mechanisms in the processes of oxidation and corrosion of the materials.

Scientific Electronic Library Online (Portuguese)

90

A utilização de diferentes configurações de molas "T" para a obtenção de sistemas de forças otimizados/ Using different T-loops configurations to obtain optimized force systems

Thiesen, Guilherme; Rego, Marcus Vinicius Neiva Nunes do; Menezes, Luciane Macedo de; Shimizu, Roberto Hideo
2006-10-01

Resumo em português OBJETIVO: determinar as características mecânicas de molas "T" e "T" com helicóides, quando da incorporação de variações na liga metálica (aço inoxidável e beta-titânio), na intensidade de dobras de pré-ativação (0º e 40º/180º) e na secção transversal do fio utilizado para a construção destas molas (0,017" x 0,025" e 0,019" x 0,025"). METODOLOGIA: foram submetidas ao ensaio mecânico 80 molas para fechamento de espaços, sendo estas centralizadas em u (mais) m espaço de 21mm. As magnitudes de força horizontal, proporção momento/força e relação carga/deflexão produzidas pelos corpos de prova foram quantificadas utilizando-se um transdutor de momentos acoplado ao módulo indicador digital para extensiometria e adaptado a uma máquina universal de ensaios Instron. As molas foram submetidas a uma ativação total de 5mm, sendo registrados os valores a cada 1mm de ativação. No tratamento estatístico dos dados obtidos, foi realizada a análise de variância, sendo esta complementada pelo teste de comparações múltiplas de Tukey, considerando o nível de significância de 5%. RESULTADOS E CONCLUSÕES: os resultados demonstraram que, de maneira geral, as molas "T" com helicóides produziram menores magnitudes de força horizontal e relação carga/deflexão do que as molas "T". Na presença de pré-ativação, as molas produziram altas proporções momento/força, enquanto, na ausência de dobras de pré-ativação, as mesmas geraram baixas proporções momento/força. Dentre todas as variáveis analisadas, aquela que apresentou uma maior influência na força horizontal e na relação carga/deflexão produzidas pelas molas foi a liga metálica. Já a proporção momento/força mostrou ser influenciada em maior grau pela pré-ativação das molas de fechamento. Resumo em inglês ABSTRACT AIM: the present study determined the force systems produced by T-loop and T-loop with helices, with employment of different alloys (stainless steel and beta-titanium), different preactivation bends intensities (0º and 40º/180º) and different transverse sections (0.017" x 0.025" and 0.019" x 0.025"). METHODS: 80 loops for space closure were submitted to mechanical testing, which were centralized in a space of 21mm. The magnitudes of horizontal force, moment/fo (mais) rce ratio and load/deflection ratio were quantified using a moment transducer connected to a digital indicator for extensometry adapted to an Instron universal testing machine (model TTDML). The specimens were distended to a total activation of 5mm, being registered the values at every 1mm of activation. The data achieved were statistically analyzed by means of variance analysis and the Tukey test for multiple comparisons at a significance level of 5%. RESULTS AND CONCLUSION: in general, the results indicated that the T-loops with helices produced lower magnitudes of horizontal force and load/deflection ratio than the T-loops. When inserted with the preactivation bends, the loops yielded high magnitudes of moment/force ratios, while when these preactivation bends were not presented, the moment/force ratios were low. The metallic alloy was the variable that presented the largest influence on the horizontal force and load/deflection ratio. The moment/force ratio was more intensely influenced by the incorporation of preactivation bends in the closure loops.

Scientific Electronic Library Online (Portuguese)

91

Avaliação do uso de haste bloqueada e bloqueio transcortical no reparo de fraturas diafisárias de fêmur em felinos/ Evaluation of the use of interlocking nail and transcortical blockade for the repair of diaphyseal fractures of the femur in cats

Romano, Leandro; Ferrigno, Cássio R. Auada; Ferraz, Vanessa C. Magalhães; Della Nina, Marcos Ishimoto; Ito, Kelly Cristiane
2008-04-01

Resumo em português As hastes bloqueadas além de permitirem estabilização rígida de fraturas, possuem vantagens biomecânicas quando comparadas a outras técnicas de imobilização, por atuar ao longo do eixo mecânico central do osso, além de preservar os conceitos de padrões biológicos de osteossíntese . O uso limitado de hastes bloqueadas em gatos se atribui ao fato da cavidade intramedular ser pequena, limitando o tamanho e diâmetro dos pinos. Relatam-se casos de 10 felinos que (mais) apresentavam fraturas fechadas simples ou múltiplas da diáfise femoral. Os animais pesavam entre 3,5 e 5 kg, o que permitiu a utilização de hastes de 4,0mm e 4,7mm de diâmetro. Para inserção da haste, adotou-se a via retrógrada ou a normógrada e foram realizados bloqueios com quatro parafusos de titânio de 2,0 mm de diâmetro. Complicações intra-operatórias não ocorreram, entretanto um animal sofreu fratura de colo femoral e fratura transversa distal ao implante, três dias após o ato cirúrgico, devido a novo trauma. Os animais foram submetidos a exames radiográficos até quatro meses após a intervenção, evidenciando-se formação de calo ósseo secundário e consolidação óssea em período de 61-89 dias. Clinicamente, ocorreu esporadicamente alteração na marcha por leve claudicação de apoio definida por escala de claudicação, entretanto os animais iniciaram o apoio adequado entre três e oito dias após o ato operatório. Complicações pósoperatórias ocorreram referentes ao animal que sofreu novo trauma, entretanto notou-se consolidação do foco primário tratado pelo implante com 61 dias e consolidação da nova fratura num período total de 150 dias do início do tratamento conservativo por penso esparadrapado e tala. Conclui-se que o uso de haste bloqueada em felinos foi adequado uma vez que houve consolidação óssea em todos os casos, com retorno precoce da função do membro, permitindo a deambulação. Resumo em inglês Interlocking nails allow rigid fracture stabilization and present biomechanical advantages when compared to other immobilization techniques. It acts along the central mechanical axis of the bone and preserves biological concept standards for osteosynthesis. The use of interlocking nail in cats is limited because the intramedullary space is relatively small for the available nail sizes. We reported 10 cases of cats that had simple or multiple closed fractures of the femora (mais) l diaphysis. The animals weighed 3.5 to 5 kg , which allowed using nails of 4.0mm and 4.7mm in diameter. For the nail insertion, retrograde and normograde routs were used, and four 2mm titanium screws were used to lock all the perforations. No trans-surgical complication occurred, however, due to a new trauma, one of the animals suffered femoral neck fracture and transversal distal fracture to the nail, three days after surgery. Radiographies were made up to four months after surgery, and in most cases secondary bone formation was seen, showing bone consolidation in 61-89 days, excluding the animal who suffered new trauma, who presented bone healing in 150 days. Clinically, occasional lameness occurred; however, except for the animal that had new trauma, all animals initiated adequate limb support in 3 to 8 days after surgery. In conclusion, the use of 4.0mm and 4.7mm interlocking nails in felines was adequate, with bone healing in all cases, and also return of good limb function after surgery.

Scientific Electronic Library Online (Portuguese)

92

Consumo e desempenho de animais alimentados individualmente ou em grupo e características de carcaça de animais Nelore de três classes sexuais/ Performance of animals fed individually or in groups and carcass traits of Nellore cattle from three sexual classes

Marcondes, Marcos Inácio; Valadares Filho, Sebastião de Campos; Paulino, Pedro Veiga Rodrigues; Detmann, Edenio; Paulino, Mário Fonseca; Diniz, Luciana Lacerda; Santos, Tathyane Ramalho
2008-12-01

Resumo em português Esta pesquisa foi realizada com os objetivos de estimar os consumos individuais de matéria seca, concentrado e volumoso de bovinos alimentados em grupo, avaliar o consumo de matéria seca (CMS), o ganho médio diário (GMD) e a conversão alimentar (CA) de bovinos de três classes sexuais (machos não-castrados, machos castrados e fêmeas) alimentados individualmente ou em grupo, com dois níveis de oferta de concentrado (OC) (1,00 ou 1,25% do peso vivo), e analisar as c (mais) aracterísticas de carcaça de animais Nelore terminados em confinamento. Utilizaram-se 45 bovinos Nelore - 15 machos castrados (MC), 15 machos não-castrados (MNC) e 15 fêmeas (FE). Desses animais, nove (três de cada classe) foram abatidos no início do experimento e serviram como referência nas avaliações. Os animais restantes (36) foram distribuídos em dois esquemas de alimentação (EA) e alimentados, individualmente ou em grupo, com dois níveis de concentrado, perfazendo um esquema fatorial 2 × 2 × 3. Nas avaliações, utilizaram-se a LIPE® para estimativa da produção fecal; o óxido crômico e o dióxido de titânio para determinação do consumo de concentrado; e a FDNi e FDAi para estimativa do consumo de volumoso. Ao final do experimento, todos os animais alimentados individualmente foram abatidos para avaliação das carcaças e dos rendimentos de cortes. O esquema de alimentação não influenciou o consumo de matéria seca nem o ganho médio diário dos animais. Ofertas de 1,00 ou 1,25% do PV em concentrado não influenciaram o rendimento e as principais características de carcaça. Machos Nelore não-castrados ganham 24% a mais de peso que machos castrados, que, por sua vez, ganham 22% a mais que as fêmeas. Entre as classes sexuais, machos não-castrados são mais eficientes que os castrados e as fêmeas na deposição de carne e apresentam maiores rendimentos de alguns cortes básicos. Resumo em inglês The present work aimed to estimate the individual intake of dry matter, concentrated and forage for animals feed in group. Evaluate also, dry matter intake, average daily gain and feed conversion ratio by animals from one of three genders (bulls, steers or heifers) fed individually or in groups, with two levels of concentrate offer (1.00 or 1.25% of BW), and carcass traits of confined Nellore cattle. Forty five Nellore cattle - 15 bulls, 15 steers and 15 heifers were used (mais) . Nine animals (three from each gender) were slaughtered at beginning of the trial performing reference group. The remaining 36 animals were fed either 1.0 or 1.25% of concentrate under two feeding schemes (individually or in groups), in a 2 × 2 × 3 factorial arrangement. In order to estimate the individual DMI of animals fed in group, LIPE® was used to estimate the fecal dry matter production, Cr2O3 and TiO2 were used to estimate the individual concentrate intake and NDFi and ADFi were used to estimate the individual forage intake. At the end of the experiment all animals individually fed were slaughtered to evaluate carcass traits and yield of commercial cuts. The feed scheme had no influence upon DMI and DWG of Nellore cattle from different gender. There were no effect of 1.00 or 1.25% of concentrate on carcass traits and carcass yield. Bulls grow 24% more than steers and steers grow 22% more than females and bulls tend to be more efficient in meat deposition and had higher yield in some commercial cuts.

Scientific Electronic Library Online (Portuguese)

93

Formação dos aluminetos de níquel a partir de pós metálicos

Santos, R.
2010-06-01

Resumo em português O carácter exotérmico da reacção de formação de aluminetos de níquel a partir dos constituintes elementares, e a elevada velocidade de libertação de energia que lhe está associada, apresenta um elevado potencial para ser utilizado em vários processos industriais. Neste trabalho foi estudada a reacção de formação do NiAl a partir de pós de Ni e Al, com vista à sua utilização como material de adição na ligação por difusão no estado sólido entre comp (mais) onentes de aluminetos de titânio e níquel. O calor gerado pela reacção será libertado directamente na zona da ligação promovendo a difusão, possibilitando a união a temperaturas inferiores às habitualmente utilizadas. Nesta investigação foram preparados compactos em verde de uma mistura de pós de níquel e alumínio na proporção equimolar e realizaram-se ensaios de calorimetria diferencial de varrimento nesses compactos bem como em pós não compactados. Os produtos resultantes foram caracterizados por microscopia electrónica de varrimento e analisados quimicamente por espectroscopia de dispersão de energia de raio-X. Paralelamente foram feitas análises por difracção de raio-X, apenas sobre os pós não compactados. Os ensaios de calorimetria diferencial de varrimento confirmaram o carácter exotérmico da reacção entre o níquel e o alumínio, não sendo a quantidade de calor libertado uma função explícita da taxa de aquecimento. A intensidade dessa libertação é condicionada pela taxa de aquecimento, aumentando para aquecimentos mais rápidos; este efeito é reforçado pela pressão de compactação dos pós, sendo maior para pressões maiores. Antes da reacção, os pós não compactados permanecem no seu estado metálico mas apresentam zonamento de composição após a reacção, na qual são formados vários intermetálicos, Ni3Al, NiAl e Ni2Al3. Os pós compactados também apresentam um zonamento idêntico, composto pelas mesmas fases. Uma excepção verificou-se para os pós compactados a 637MPa; quando aquecidos a 30ºC/min. até 750ºC apresentam uma composição homogénea de NiAl. Resumo em inglês The exothermic behavior of nickel aluminides formation from its elemental constituents and its high energy release rate represents a big potential for use in many industrial processes. In this work it was studied the formation reaction of NiAl from Ni and Al powders, looking for its use as bonding material for solid state diffusion joining of nickel and titanium aluminides. The reaction’s generated heat is released directly at the bonding zone, promoting the diffusion an (mais) d making possible the joining at lower temperatures than usual. In this investigation green compacts from a nickel and aluminium were prepared in an equimolar blend; the reactions occurring in the blends were studied by differential scanning calorimetric tests on both, compacted performed calorimetric tests on both, compacted and non compacted powders. Reaction products characterized by scanning electron microscopy and chemically analyzed by energy dispersive X-rar spectroscopy. Non compacted powders ere also characterizes by X-ray diffraction. Differential scanning calorimetric experiments confirmed the exothermic behavior of the reaction between nickel and aluminium, showing that heat release is not an explicit function of heating rate. That release’s intensity is conditioned by the heating rate, being higher for faster heating rates; this effect is enhanced by powders compaction pressure, being higher for higher pressures. Before the reaction, non compacted powders remain metallic but, after the reaction several intermetallics are formed, Ni3Al, NiAl e Ni2Al3, resulting in a composition gradient across the particles. Compacted powders also present similar composition gradient. An exception was noticed for powders compacted at 637MPa; when heated at 30ºC/min. up to 750ºC they show a homogeneous composition of NiAl.

Scientific Electronic Library Online (Portuguese)

94

Mini-placa como ancoragem ortodôntica: relato de caso/ Mini screw as orthodontic anchorage: case report

Zétola, André Luiz; Michaelis, Guilherme; Moreira, Francielli Miquelini
2005-08-01

Resumo em português Seria dispensável afirmar que o controle da ancoragem é fundamental para o sucesso do tratamento ortodôntico, sem ela seria impossível a obtenção de uma oclusão ideal através de uma mecânica ortodôntica. O advento da utilização de dispositivos rígidos, originários dos princípios da traumatologia de face e da implantodontia, para a ancoragem rígida na Ortodontia, principalmente nos casos da dificuldade ou impossibilidade da sua obtenção, revolucionou a fo (mais) rma de tratar casos que tinham um prognóstico insatisfatório. O objetivo desse artigo foi revisar a literatura em relação ao uso dos pinos de ancoragem ortodôntica, relatar um caso com a sua utilização e discutir alguns aspectos em relação à ancoragem rígida na Ortodontia. A ancoragem rígida foi utilizada em uma paciente do gênero feminino, com 39 anos de idade que possuía os elementos 26 e 27 com extrusão importante devido à ausência dos antagonistas. Foi instalado um aparelho fixo superior, utilizando uma barra transpalatina nos elementos dentários 15 e 25 para ancoragem com objetivo de intruir os molares superiores esquerdos e o dispositivo quadri-hélice para auxiliar no descruzamento do dente 18. Como a intrusão ortodôntica com apenas ancoragem dentária não havia tido um resultado muito satisfatório até então, foi instalada uma placa de titânio em forma de "L" na região apical dos elementos 26 e 27 com o objetivo de obter uma ancoragem ortodôntica rígida para a intrusão desses elementos. O tempo de força intrusiva através de elásticos verticais foi de cinco meses e a intrusão obtida foi de 6 mm. Após a remoção do aparelho ortodôntico, fez-se a clareação dentária superior e inferior, instalação de prótese definitiva sobre os implantes e reabilitação estética dentária. Através dos relatos anteriores e da presente experiência, além de outros casos ainda não concluídos, pode-se sugerir que a utilização da ancoragem rígida pode ser utilizada com bastante propriedade no tratamento ortodôntico qunado for requerida uma ancoragem máxima. Resumo em inglês It is needless to say that anchorage control is necessary to a successful orthodontic treatment. Without it, it would be impossible to obtain an ideal occlusion through orthodontic mechanics in the majority of cases. The utilization of rigid devices, originated from face traumatology and implant dentistry principles, to obtain rigid anchorage in orthodontics revolutionized the way of treating cases with an unsatisfactory prognosis. Specially in cases where a lot of anchor (mais) age is needed and it is difficult or impossible to get it. The objective of this article was to revise the literature related to the use of mini-screw implant systems, to report a case where it was utilized and to discuss some aspects related to the usage of rigid anchorage orthodontics. The rigid anchorage was used in a 39 year old female patient, who had the upper left molars with a relevant extrusion due to the absence of the lower left molars. Fixed appliances were placed on the upper arch with a TPA connecting the second bicuspids. The TPA was used to anchor the intrusion of the upper left molars. A quad-helix appliance was used to correct the upper right third molar crossbite. Since the orthodontic intrusion with only dental anchorage did not have a satisfactory result, an "L" shaped titanium plate was placed on the maxilla, at the apical region of the upper first and second left molars, with the purpose of obtaining a rigid orthodontic anchorage to intrude them. Elastics were used during five months with intrusive force,the obtained intrusion was 6 millimeters. After the removal of the appliance, upper and lower dental bleaching was made and final prosthesis were placed over the implants. Through the literature reviewed and the case reported, it can be concluded that rigid anchorage can be indicated in orthodontic treatments where there is lack of anchorage or the need of an absolute anchorage.

Scientific Electronic Library Online (Portuguese)

95

Estudo biomecânico comparativo da resistência a forças de compressão entre os parafusos pediculares poliaxiais com travamento tipo Dytech® e parafusos pediculares poliaxiais com travamento tipo Lock 1®/ Biomechanical comparative study of compression strength between poliaxial screws Dytech® Locked type and poliaxial screws Lock 1®/ Estudio biomecánico comparativo de la resistencia a fuerzas de compresión entre los tornillos pediculares poliaxiales con traba tipo Dytech® y tornillos pediculares poliaxiales con traba tipo Lock 1®

Oliveira, Mauricio Pagy de Calais; França, Luiz Cláudio de Moura; Ruggani, Marcelo Gonçalves; Pedrosa, Luiz Olímpio Garcia; Fontes, Bruno Pinto Coelho; Macedo, Rodrigo D'Alessandro de; Duarte, Rafael Gonçalves; Duarte, Marcelo Gonçalves Pereira
2010-09-01

Resumo em português OBJETIVO: Comparar a rigidez de um sistema de fixação pedicular composto por parafusos pediculares poliaxiais de travamento tipo Dytech® com outro composto por parafusos pediculares poliaxiais com travamento do tipo Lock 1®, submetidos a forças de compressão. MÉTODOS: A amostra utilizada para avaliar os sistemas de fixação respeitou as regras do padrão formulado pela American Society for Testing Materials (ASTM) no ensaio F1717-04. Os modelos foram divididos em: (mais) Grupo 1, composto pelos ensaios de parafusos poliaxiais com sistema Dytech® de travamento, e o Grupo 2, formado por parafusos poliaxiais com travamento tipo Lock 1®. Foram testados três conjuntos completos montados. Cada sistema foi testado uma única vez por ser esse um ensaio destrutivo. O instrumental implantado foi produzido com titânio de mesma origem. Os grupos experimentais foram submetidos a testes mecânicos na máquina universal de ensaios EMIC, modelo EMIC DL 10000®. RESULTADOS: Os resultados de compressão nas amostras do Grupo 1 tiveram uma carga máxima média de 967,17 N e carga de escoamento média de 804,71 N. Nas amostras do Grupo 2 tivemos uma carga máxima média de 906,04 N e carga de escoamento média de 834,56 N. A respeito da integridade dos instrumentais metálicos usados, não foi observado nenhum tipo de escorregamento ou soltura de porcas, parafusos ou outros componentes. CONCLUSÃO: O sistema de parafusos poliaxiais com travamento tipo Dytech® apresentou valores de rigidez maiores, enquanto o sistema de parafusos com travamento tipo Lock 1® mostrou deslocamento máximo maior. Resumo em espanhol OBJETIVO: comparar la rigidez de un sistema de fijación pedicular compuesto por tornillos pediculares poliaxiales de traba tipo Dytech® con otro compuesto por tornillos pediculares poliaxiales con traba del tipo Lock 1®, sometidos a fuerzas de compresión. MÉTODOS: la muestra utilizada para evaluar los sistemas de fijación respetó las reglas del patrón formulado por la American Society for Testing Materials (ASTM) en el ensayo F1717-04. Los modelos fueron divididos (mais) en: Grupo 1, compuesto por los ensayos de tornillos poliaxiales con sistema Dytech® de traba, y el Grupo 2, formado por tornillos poliaxiales con traba tipo Lock 1®. Fueron probados tres conjuntos completos montados. Cada sistema fue probado una vez por ser ese un ensayo destructivo. El instrumental implantado fue producido con titanio del mismo origen. Los grupos experimentales fueron sometidos a pruebas mecánicas en la máquina universal de ensayos EMIC, modelo EMIC DL 10000®. RESULTADOS: los resultados de compresión en las muestras del Grupo 1 tuvieron una carga máxima promedio de 967.17 N y carga de declive promedio de 804.71 N. En las muestras del Grupo 2, tuvimos una carga máxima promedio de 906.04 N y carga de declive promedio de 834.56 N. Con respecto a la integridad de los instrumentales metálicos usados, no fue observado ningún tipo de deslizamiento o soltura de tuercas, tornillos y otros componentes. CONCLUSIÓN: el sistema de tornillos poliaxiales con traba tipo Dytech® presentó valores de rigidez mayores, mientras que el sistema de tornillos con traba tipo Lock 1® mostró un desplazamiento mayor. Resumo em inglês OBJECTIVE: To compare rigidity of a pedicle fixation system composed of poliaxial pedicle screws with Dytech® lock system to one composed of poliaxial screws with Lock 1® system, submitted to compression strengths. METHODS: The sample used to evaluate the fixation systems respected the norms of the standard described by the American Society for Testing Materials (ASTM) in trial F1717-04. The models were divided into: Group 1, composed of trials using poliaxial screws wi (mais) th Dytech® system, and Group 2, used poliaxial screws with Lock 1® system. Three complete sets were tested. Each system was tested only once because it´s a destructive essay. The implanted components were produced with titanium coming from the same origin. The experimental groups were submitted to mechanical tests in a universal testing machine EMIC, model EMIC DL 10000®. RESULTS: The samples of Group 1 showed an average maximum charge of 967,17 N, and an average discharging load of 814,71 N. The samples of Group 2 showed an average maximum charge of 906,04 N, and an average discharging load of 834,56 N. About the integrity of the used metallic components, was not noted any kind of failure in all of them. CONCLUSION: The pofilaxial screws system with Dytech® lock has presented greater rigidity, while the Lock 1® system screws showed greater maximum displacement.

Scientific Electronic Library Online (Portuguese)