Sample records for standard reference materials
from WorldWideScience.org

Sample records 1 - 17 shown.



1

Avaliação do kerma no ar na superfície de entrada e da qualidade da imagem em radiografias de tórax/ Evaluation of entrance surface air kerma rate and clinical images quality in chest radiography

Souza, Angelo Bernardo Brasil de; Dias, Simone Kodlulovich; Augusto, Fernando Mecca; Marques, Winston Andrade
2009-10-01

Resumo em português OBJETIVO: Avaliar os fatores de técnica utilizados durante exames de tórax póstero-anterior em pacientes-padrão e correlacioná-los aos valores de kerma no ar na superfície de entrada e à qualidade das imagens clínicas. MATERIAIS E MÉTODOS: O estudo foi realizado em três hospitais do Rio de Janeiro, num total de cinco salas de raios X, com dez pacientes por sala. As imagens foram avaliadas pelos radiologistas dos serviços segundo o protocolo europeu. O kerma no (mais) ar na superfície de entrada foi estimado a partir da curva de rendimento do equipamento de raios X, que foi obtida utilizando câmara de ionização acoplada a um eletrômetro. Análise de variância foi realizada para verificar se a diferença entre os valores de kerma no ar na superfície de entrada é significativa. RESULTADOS: Os valores de kerma no ar na superfície de entrada variaram entre 0,05 e 0,26 mGy, com média 60% inferior ao nível de referência publicado na Portaria 453. Das imagens avaliadas, 98% atenderam acima de 65% dos critérios de qualidade. CONCLUSÃO: Para um padrão de qualidade da imagem, aceitável para o diagnóstico, verificou-se ampla variação do kerma no ar na superfície de entrada para pacientes-padrão. Isto demonstra a falta de padronização dos fatores de técnica e a existência de um potencial de redução do valor do kerma no ar na superfície de entrada. Resumo em inglês OBJECTIVE: To evaluate technical factors involved in posteroanterior chest radiography in standard patients, and correlating them with entrance surface air kerma rate and with the clinical images quality. MATERIALS AND METHODS: The present study was developed at three hospitals in Rio de Janeiro, Brazil, involving a total of five x-ray rooms, with ten patients per room. The images were evaluated by the radiologists of the institutions, in accordance with the European prot (mais) ocol. The estimation of surface entrance air kerma rate was based on the x-ray equipment output curve obtained with an ionization chamber coupled with an electrometer. Variance analysis was performed to evaluate the significance of the difference between entrance surface air kerma rates. RESULTS: Entrance surface air kerma rates ranged between 0.05 and 0.26 mGy, with a mean value 60% lower than the reference level established by the Order (Portaria) 453. Among the images evaluated, 98% fulfilled > 65% of the images quality criteria. CONCLUSION: For a standard image quality that is acceptable for diagnosis purposes, a significant variation was observed in the entrance surface air kerma rate for standard patients, demonstrating the lack of technical factors standardization and a potential for decreasing the entrance surface air kerma rate.

Scientific Electronic Library Online (Portuguese)

2

Intercomparação e calibração de medidores de atividade utilizados em serviços de medicina nuclear/ Intercomparison and calibration of dose calibrators used in nuclear medicine facilities

Costa, Alessandro Martins da; Caldas, Linda V.E.
2003-10-01

Resumo em português OBJETIVO: O objetivo deste trabalho foi estabelecer um padrão de trabalho para intercomparação e calibração de medidores de atividade (calibradores de dose) utilizados na maioria dos serviços de medicina nuclear, para determinação da atividade dos radionuclídeos administrados aos pacientes nos exames específicos ou nos procedimentos terapêuticos. MATERIAIS E MÉTODOS: Foi utilizado um calibrador de dose comercial, um conjunto de fontes radioativas padrões, al� (mais) �m de seringas, frascos e ampolas contendo soluções de radionuclídeos utilizados em medicina nuclear. RESULTADOS: O calibrador de dose comercial foi calibrado com soluções de radionuclídeos utilizados em medicina nuclear. Os testes simples do instrumento, tais como o teste de linearidade e da variação da resposta com o volume da fonte a uma concentração de atividade constante, foram descritos e realizados. CONCLUSÃO: O instrumento estudado pode agora ser utilizado como sistema de referência para intercomparação e calibração de outros instrumentos medidores de atividade, como um método de controle da qualidade de calibradores de dose utilizados em serviços de medicina nuclear. Resumo em inglês OBJECTIVE: The aim of this work was to establish a working standard for intercomparison and calibration of dose calibrators used in most of nuclear medicine facilities for the determination of the activity of radionuclides administered to patients in specific examinations or therapeutic procedures. MATERIALS AND METHODS: A commercial dose calibrator, a set of standard radioactive sources, and syringes, vials and ampoules with radionuclide solutions used in nuclear medicin (mais) e were utilized in this work. RESULTS: The commercial dose calibrator was calibrated for radionuclide solutions used in nuclear medicine. Simple instrument tests, such as linearity response and variation response with the source volume at a constant source activity concentration were performed. CONCLUSION: This instrument may be used as a reference system for intercomparison and calibration of other activity meters, as a method of quality control of dose calibrators utilized in nuclear medicine facilities.

Scientific Electronic Library Online (Portuguese)

3

Medida do comprimento do osso nasal entre 11 e 15 semanas de gestação em uma população brasileira: estudo preliminar/ Measurement of fetal nasal bone length in the period between 11 and 15 gestational weeks in a Brazilian population: a preliminary study

Cossi, Paulo Sérgio; Araujo Júnior, Edward; Bussamra, Luiz Cláudio de Silva; Guimarães Filho, Hélio Antonio; Nardozza, Luciano Marcondes Machado; Moron, Antonio Fernandes
2008-06-01

Resumo em português OBJETIVO: Determinar valores de referência para o comprimento do osso nasal entre 11 e 15 semanas de gestação em uma população brasileira. MATERIAIS E MÉTODOS: Realizou-se estudo de corte transversal com 171 gestantes normais entre 11 e 15 semanas completas. O osso nasal foi medido por via transabdominal em todos os casos. Foram calculados os percentis 5 a 95 para o comprimento do osso nasal pela fórmula: média ± 1,645 desvio-padrão. Para avaliar a correlação (mais) do comprimento do osso nasal com parâmetros antropométricos fetais utilizou-se o coeficiente de correlação de Spearman, com intervalo de confiança de 95%. RESULTADOS: O osso nasal foi mensurado em todos os casos, sendo que o comprimento médio variou de 1,69 mm a 2,94 mm. O comprimento do osso nasal mostrou-se fortemente correlacionado com todos os parâmetros antropométricos fetais (p Resumo em inglês OBJECTIVE: To establish reference values for fetal nasal bone length measurements between 11 and 15 gestational weeks in a Brazilian population. MATERIALS AND METHODS: A cross-sectional study was developed with 171 normal pregnant women between their 11th and 15th gestational weeks. The fetal nasal bone was measured by means of transabdominal ultrasound in all of the cases. The 5th and 95th percentiles for the nasal bone length were calculated by the formula: mean ± 1.64 (mais) 5 standard deviation. The Spearman correlation coefficient with 95% confidence interval was utilized to correlate the nasal bone length with fetal anthropometric parameters. RESULTS: The nasal bone could be measured in all of the cases with the mean length ranging between 1.69 mm and 2.94 mm. Nasal bone length demonstrated to be strongly correlated with all of the fetal anthropometric parameters (p

Scientific Electronic Library Online (Portuguese)

4

Avaliação do volume da placenta no primeiro trimestre de gestação por meio da ultrassonografia tridimensional utilizando o método XI VOCAL/ Estimation of placental volume by three-dimensional ultrasonography with the XI VOCAL method in the first gestational trimester

Nowak, Paulo Martin; Nardozza, Luciano Marcondes Machado; Araujo Júnior, Edward; Rolo, Liliam Cristine; Guimarães Filho, Hélio Antonio; Moron, Antonio Fernandes
2010-04-01

Resumo em português OBJETIVO: Determinar valores de referência para o volume da placenta entre 7 e 10 semanas e 6 dias de gestação por meio da ultrassonografia tridimensional utilizando o método XI VOCAL (eXtended Imaging Virtual Organ Computer-aided Analysis). MATERIAIS E MÉTODOS: Realizou-se estudo de corte transversal com 70 gestantes normais entre 7 e 10 semanas e 6 dias. Para o cálculo de volume, utilizou-se o método XI VOCAL com delimitação de dez planos adjacentes. Foram dete (mais) rminadas médias, medianas, desvios-padrão, valores máximo e mínimo para o volume da placenta. Para avaliar a correlação do volume da placenta com a idade gestacional, foi criado gráfico de dispersão, sendo o ajuste realizado pelo coeficiente de determinação (R²). RESULTADOS: A média do volume da placenta variou de 4,6 cm³ (2,6-8,6 cm³) a 28,9 cm³ (11,4-66,9 cm³). O volume da placenta (VP) se mostrou altamente correlacionado com a idade gestacional (IG), sendo o melhor ajuste com a regressão exponencial [VP = exp(0,582 × IG + 0,063); R² = 0,82]. CONCLUSÃO: Valores de referência para o volume da placenta no primeiro trimestre de gestação utilizando o método XI VOCAL foram determinados. Resumo em inglês OBJECTIVE: To determine reference values for placental volume at 7 to 10 + 6 weeks of gestation by means of three-dimensional ultrasonography with the XI VOCAL (eXtended Imaging Virtual Organ Computer-aided Analysis) method. MATERIALS AND METHODS: A cross-sectional study was developed with 70 pregnant women at 7 to 10 + 6 weeks of gestation. The XI VOCAL method with ten sequential adjacent planes was utilized in the volume calculations. Means, medians, standard deviation, (mais) minimum and maximum values for placental volume were calculated. A scatter plot adjusted by the determination coefficient (R²) was constructed to correlate placental volume and gestational age. RESULTS: Mean placental volume ranged from 4.6 cm³ (2.6-8.6 cm³) to 28.9 cm³ (11.4-66.9 cm³). The placental volume (PV) has shown to be highly correlated with the gestational age (GA) and the best fit equation was [PV = exp(0.582 × GA + 0.063); R² = 0.82]. CONCLUSION: Reference values for placental volume in the first gestational trimester were determined with the XI VOCAL method.

Scientific Electronic Library Online (Portuguese)

5

Teste de proficiência para medições de radioatividade na medicina nuclear/ Proficiency test for radioactivity measurements in nuclear medicine

Iwahara, Akira; Tauhata, Luiz; Oliveira, Antonio Eduardo de; Nícoli, Ieda Gomes; Alabarse, Frederico Gil; Xavier, Ana Maria
2009-08-01

Resumo em português OBJETIVO: Avaliar o desempenho dos calibradores de radionuclídeos de 55 serviços de medicina nuclear brasileiros em medição de atividade de radiofármaco contendo 99Tc m. Testes de proficiência foram aplicados em 63 resultados originados do programa de comparação promovido pelo Laboratório Nacional de Metrologia das Radiações Ionizantes do Instituto de Radioproteção e Dosimetria. MATERIAIS E MÉTODOS: O desempenho foi avaliado em relação ao critério de acei (mais) tação de ±10% de exatidão exigido pela norma brasileira e também aos critérios estabelecidos pela ISO/IEC Guide 43-1, e classificado como "aceitável" ou "não aceitável". Amostras de 99Tc m usadas nas comparações foram fornecidas por alguns dos participantes e calibradas no Laboratório Nacional de Metrologia das Radiações Ionizantes para determinar o valor de referência da atividade. RESULTADOS: Esta comparação com o 99Tc m mostrou que o desempenho aceitável atendendo à exigência da norma regulatória foi de 82,5%, enquanto pelos critérios estabelecidos pela norma ISO/IEC 43-1 foi de 81,0%. Por outro lado, calibradores de radionuclídeos com detector Geiger-Müller apresentaram desempenho inferior quando comparados com os dotados com câmara de ionização. CONCLU-SÃO: Nesta comparação, a avaliação do desempenho baseada nos critérios da ISO/IEC 43-1, os quais são aplicados a laboratórios analíticos, apesar de serem mais restritivas, foi bastante consistente com o critério de exatidão exigido pela norma nacional. Resumo em inglês OBJECTIVE: To assess the performance of radionuclide calibrators in 55 Brazilian nuclear medicine services in the measurement of 99Tc m radiopharmaceutical activity. Proficiency tests were applied to data sets with 63 results originated from the comparison program developed by Laboratório Nacional de Metrologia das Radiações Ionizantes of Instituto de Radioproteção e Dosimetria. MATERIALS AND METHODS: The calibrators' performance was evaluated in compliance with the (mais) acceptance criterion of ±10% accuracy required by the Brazilian standards and also the criteria established by the ISO/IEC Guide 43-1, and classified as either "acceptable" or "non-acceptable". The samples of 99Tc m utilized in the comparison were supplied by some of the participants and calibrated at Laboratório Nacional de Metrologia das Radiações Ionizantes for determining the activity reference value. RESULTS: The present study utilizing 99Tc m has shown that 82.5% of the calibrators were considered as acceptable according to the Brazilian standards, while by the criteria established by ISO/IEC 43-1, 81.0% were considered as acceptable. On the other hand, radionuclide calibrators with Geiger-Müller detectors presented unsatisfactory performance when compared with calibrators with ionization chambers. CONCLUSION: The performance evaluation based on the ISO/IEC 43-1 criteria, which are applied to analytical laboratories, in spite of being more restrictive, has demonstrated to be quite consistent with the accuracy criterion established by the Brazilian standard.

Scientific Electronic Library Online (Portuguese)

6

Rendimento e comportamento espectrofotométrico da lignina extraída de preparações de parede celular, fibra em detergente neutro ou fibra em detergente ácido/ Yield and spectrophotometric pattern of lignin extracted from cell wall, neutral detergent fiber or acid detergent fiber

Savioli, Nancy Maria de Fátima; Fukushima, Romualdo Shigueo; Lima, César Gonçalves de; Gomide, Catarina Abdalla
2000-08-01

Resumo em português A lignina extraída da planta forrageira pelo reagente brometo de acetila (lignina brometo de acetila - LBrAc), para ser empregada como padrão de referência no método espectrofotométrico para a determinação quantitativa da lignina, não pode originar-se da planta intacta, devido à interferência de diversas outras substâncias, que absorvem no mesmo comprimento de onda que a lignina; aconselha-se, portanto, que a extração da lignina seja realizada a partir de um (mais) dos seguintes compostos: parede celular propriamente dita (PC), fibra em detergente neutro (FDN) ou fibra em detergente ácido (FDA). Os rendimentos das extrações das ligninas, bem como o comportamento espectrofotométrico das mesmas, foram avaliados nestes três compostos provenientes de diversas plantas forrageiras. Na média, os rendimentos das extrações de LBrAc foram relativamente uniformes entre si, entretanto, como a concentração de FDA foi a menor entre todas as preparações (devido principalmente à solubilização da hemicelulose) e como esta não apresentou maior capacidade extrativa da lignina, o rendimento de LBrAc proveniente da FDA, com base na planta inteira, foi o menor observado. A absorção da luz ultravioleta das diversas ligninas foi desigual, revelada pelos espectrogramas traçados, de tal modo a sugerir que a preparação de parede celular adotada para o isolamento da lignina deve ser a mesma para a determinação final da concentração de lignina. Resumo em inglês The lignin extracted from the forages by the acetyl bromide reagent (acetyl bromide lignin - AcBrL) to be used as a reference standard for the quantitative spectrophotometric determination of lignin could not originate from intact plant because of interference of other substances, which absorb ultraviolet light at the same wavelength of lignin. It is then recommended that lignin extraction be performed in one of the following materials: cell wall itself (CW), neutral dete (mais) rgent fiber (NDF), or acid detergent fiber (ADF). The lignin extraction yields as well as the spectrographic pattern of those were evaluated in these three compounds that came from diverse forage plants. On the average, extraction yields of AcBrL were fairly uniform among them; however as the concentration of ADF was the lowest among all preparations (mainly due to hemicellulose solubilization) and as far this preparation did not exhibit higher lignin extraction capacity, the AcBrL concentration from ADF on a whole plant basis was the lowest observed. The ultraviolet light absorption from the diverse lignin was unequal, as revealed by the graphic spectrograms, which would suggest that the cell wall preparation used for lignin isolation must be the same for the final determination of lignin concentration.

Scientific Electronic Library Online (Portuguese)

7

Estudo da utilização de materiais de referência nas análises de água por laboratórios envolvidos no sistema de acreditação/ Case study on the usage of reference materials in water analysis by laboratories involved in the accreditation system

Moura, Suzana Saboia de; Costa, Stella Regina Reis da
2009-01-01

Resumo em português O presente estudo propõe-se discutir o uso de materiais de referência (MR) pelos laboratórios de ensaios de águas, sob o ponto de vista da aquisição dos materiais conforme o item "Aquisição de serviços e suprimentos" (4.6) da norma ABNT NBR ISO/IEC 17025. O papel dos MR nas análises químicas é fornecer referências metrológicas visando assegurar a rastreabilidade das medições. A rastreabilidade é um aspecto essencial da garantia da qualidade para se obter (mais) aceitação de dados analíticos nos mercados nacional e internacional. Neste estudo de caso, de caráter exploratório e qualitativo, uma pesquisa foi realizada junto a todos os laboratórios de ensaios prestadores de serviços analíticos para a Agência Nacional de Águas (ANA) e envolvidos no sistema de acreditação pela Coordenação Geral de Acreditação do Inmetro (Cgcre/Inmetro), utilizando-se questionário estruturado e com 50% de retorno. Os resultados mostraram que são muito poucos os certificados de MR com reconhecimento de terceira parte, ou seja, por organismos de acreditação, segundo normas consagradas que tratam efetivamente da rastreabilidade metrológica. Propõe-se, finalmente, uma política para garantir, sempre que possível, a rastreabilidade dos resultados de ensaios dos laboratórios, na ausência de MR certificados. Resumo em inglês This paper aims at discussing the use of reference materials (RM) by water testing laboratories, on the context of RM purchase, based on the requirements of the standard ABNT NBR ISO/IEC 17025, section "Purchasing services and supplies" (4.6). The role of RM in chemical analysis is to provide metrological reference to assure measurement traceability. This is an essential aspect of quality assurance in order to have analytical results accepted in the international market. (mais) In this case study, based on the methodological exploratory and qualitative approach, a questionnaire was sent to testing laboratories which provide analytical services to the National Agency for Waters involved in the accreditation system performed by the General Coordination for Accreditation of Inmetro (Cgcre/Inmetro) by using structured questionnaire and with 50% of return. The results showed that there are few RM certificates with indication of third party recognition, i.e., accreditation bodies, based on standards dealing with metrological traceability. Finally, a policy is proposed to assure the traceability of laboratories measurement results, when certified RMs are unavailable.

Scientific Electronic Library Online (Portuguese)

8

Determinação indireta de N-total em plantas por espectrometria de absorção atômica com chama empregando uma mini-coluna de AgCl(s)/ Indirect determination of N-total in plant materials by flame atomic absorption spectrometry involving a AgCl(s) mini-column

Carneiro, Josiane Meire Tolotti; Zagatto, Elias Ayres Guidetti; Mattos, Ivanildo Luiz de; Melo, Denise
2001-03-01

Resumo em português Um sistema de análises químicas por injeção em fluxo empregando uma mini-coluna de AgCl(s) é proposto para a determinação de nitrogênio total em plantas por espectrometria de absorção atômica com chama. O método se baseia na remoção de íons Ag+ por amônia com formação do complexo diamino argentato(I) e posterior direcionamento da amostra a um espectrômetro de absorção atômica onde prata é monitorada. Nitrogênio foi determinado em sete amostras de r (mais) eferência (três replicatas) com precisão e exatidão comparáveis às do procedimento condutimétrico. O sistema é estável, apresentando apenas pequenas variações em sensibilidade ( Resumo em inglês A flow-injection system with a AgCl(s) mini-column is proposed for the determination of total nitrogen in plant digests by flame atomic absorption spectrometry. The method is based on Ag+ removal by ammonia through the formation of the diammine argentate(I) complex and further monitoring of the released Ag+. Nitrogen was determined in seven reference samples, in three replicates, with precision and accuracy comparable to the conductimetric procedure. The system is robust, (mais) and only slight sensitivity variations (

Scientific Electronic Library Online (Portuguese)

9

Determinação de fósforo em aços por espectrometria de absorção atômica no forno de grafite/ Determination of phosphorus in steel samples by graphite furnace atomic absorption spectrometry

Curtius, Adilson José
1998-06-01

Resumo em inglês A method for the determination of phosphorus in steel samples by graphite furnace atomic absorption spectrometry, using the Zeeman effect background correction and the STPF conditions is proposed. The effect of iron (III) on the phosphorus signal was studied. It was verified, through the pyrolysis temperature curves, that iron (III) is an efficient chemical modifier, thermically stabilizing phosphorus up to 1400ºC. The phosphorus signal increases with the iron (III) conc (mais) entration, but in the range, which corresponds to the usual concentrations of iron in the sample solutions, the increase is small. Phosphorus was determined in three standard reference materials, after its dissolution in a mixture of hydrochloric and perchloric acids in a PTFE bomb. The agreement with the certified concentration values was excellent. Iron (III) was added to the reference analytical solutions prepared in the blank of the dissolution, while the sample solutions were measured directly, since they already contained the modifier. The detection limit (k = 2) was 0.0042% of phosphorus in the steel sample.

Scientific Electronic Library Online (Portuguese)

10

Desenvolvimento de um equipamento para a caracterização não-destrutiva dos módulos elásticos de materiais cerâmicos/ Development of equipment for non-destructive characterization of elastic moduli of ceramic materials

Pereira, A. H. A; Venet, M; Tonnesen, T; Rodrigues, J. A
2010-06-01

Resumo em português Foi desenvolvido um equipamento para a caracterização não-destrutiva dos módulos elásticos aplicável a cerâmicas, concretos e materiais frágeis baseado na norma ASTM E 1875-00. Pode-se medir com exatidão, praticidade e simultaneidade o módulo de Young, de cisalhamento e a razão de Poisson. O equipamento obtém, via espectroscopia de ressonância sônica, as freqüências naturais de vibração flexurais e torcionais do corpo de prova e calcula os módulos. O eq (mais) uipamento foi desenvolvido em três partes: suporte do corpo de prova, eletrônica e software. O suporte aplica as condições de contorno mecânicas e a excitação necessária, a eletrônica gera e capta os sinais e o software executa os cálculos. A validação foi realizada com ensaios inter-técnicas e inter-laboratoriais de materiais refratários e de referência. Os resultados mostraram que o equipamento é mais versátil do que as opções atuais para a medida simultânea das três propriedades elásticas apresentadas acima. Resumo em inglês In this work was developed an equipment for non-destructive characterization of elastic moduli applicable to ceramics, concretes, and brittle materials based on ASTM E 1875-00 standard. The Young's modulus, shear modulus and Poisson's ratio can be simultaneously and easily measured with accuracy applying the new equipment. The natural torsional and flexural vibration frequencies of the sample are measured through sonic resonance spectroscopy. This permits the calculation (mais) of the elastic moduli. The system was developed in three parts: the sample holder, the electronics and the software. The sample holder applies the mechanical boundary conditions and excitation. The electronics captures and generates the signals. Finally, the software performs the calculations. The validation was carried out with inter-laboratory and inter-technique tests of refractories and reference materials. The results showed that the equipment is more versatile than the current options to the simultaneous measurement of the elastic moduli.

Scientific Electronic Library Online (Portuguese)

11

Desenvolvimento de prótese auditiva digital para atendimento da Portaria nº 587 (APAC) do Ministério da Saúde: Health Department/ Development of a digital hearing aid to meet the Brazilian Government's Ordinance 587 (APAC)

Penteado, Silvio Pires; Bento, Ricardo Ferreira
2010-06-01

Resumo em português O tratamento das disacusias sensório-neurais está balizado no uso de próteses auditivas, conhecidas como aparelhos auditivos ou aparelhos de amplificação sonora individuais. As próteses auditivas adquiridas pelo Governo Brasileiro para a condução de políticas públicas têm como uma de suas características a utilização de componentes dedicados, o que traz benefícios, mas que encarece a aquisição e pode inviabilizar os serviços de reparo após o término da (mais) garantia do fabricante. OBJETIVO: Desenvolver próteses auditivas digitais no desenho retroauricular, construídas a partir de componentes padronizados oriundos da própria cadeia de suprimentos dos fabricantes de próteses auditivas. FORMA DE ESTUDO: Experimental. MATERIAL E MÉTODO: Identificar a cadeia de suprimentos destes fabricantes, solicitar amostras e montar próteses auditivas em laboratório. RESULTADOS: As próteses auditivas desenvolvidas apresentaram recursos eletroacústicos não inferiores àquelas adquiridas pelo Governo, sendo adicionalmente atestadas pela mesma norma técnica internacional de referência. CONCLUSÃO: É possível desenvolver próteses auditivas digitais no desenho retroauricular montados a partir de componentes padronizados da cadeia de suprimentos dos fabricantes de próteses auditivas. Suas vantagens residem no baixo custo operacional - aquisição (com vantagens para o Governo) e de manutenção (com vantagens para o paciente). Resumo em inglês The treatment of sensorineural hearing loss is based on hearing aids, also known as individual sound amplification devices. The hearing aids purchased by the Brazilian Government, aiming at fulfilling public policies, are based on dedicated components, which bring about benefits, but also render them expensive and may impair repair services after manufacture's warranty expires. AIM: to design digital behind-the-ear hearing aids built from standardized components coming fr (mais) om the very supply chain of these manufacturers. STUDY DESIGN: experimental. MATERIALS AND METHODS: to identify the supply chain of these manufacturers, request samples and set up hearing aids in the laboratory. RESULTS: The developed hearing aids did not show lesser electroacoustic characteristics when compared to those acquired by the Government, also being tested by the same reference international technical standard. CONCLUSION: It is possible to develop digital behind-the-ear hearing aids based on off-the-shelf components from hearing aid manufacturers' supply chain. Their advantages include low operational costs - for acquisition (with clear advantages for the Government) and service (advantage for the patient).

Scientific Electronic Library Online (Portuguese)

12

Decomposição de argilas em forno de microondas e determinação simultânea dos seus constituintes principais por espectrometria de emissão óptica em plasma indutivamente acoplado/ Analysis of clays by inductively coupled plasma optical emission spectrometry after closed-vessel microwave-assisted acid decomposition

Silva, Claudineia R.; Nóbrega, Joaquim A.; Blanco, Telma
2005-02-01

Resumo em inglês In this work a closed-vessel microwave-assisted acid decomposition procedure for clays was developed. Aluminum, Ca, Fe, K, Mg, Na, Si, and Ti were determined in clay digestates by inductively coupled plasma optical emission spectrometry. The most critical parameter for total decomposition of clays was the composition of the reagent mixture. The applied power and the heating time exerted a less critical influence. Best decomposition conditions were attained using a reagent (mais) mixture containing 4 mL aqua regia plus 3 mL HF and the heating program was implemented in 12 min. The accuracy of the results was demonstrated using two standard reference materials and a paired t-test showed a good agreement between determined and certified values at a 95% confidence level.

Scientific Electronic Library Online (Portuguese)

13

Avaliação de concreto de cimento Portland contendo resíduos de PET/ Evaluation of concrete made of Portland cement containing PET wastes

Modro, N.L.R.; Modro, N.R.; Modro, N.R.; Oliveira, A.P.N.
2009-04-01

Resumo em português O objetivo deste trabalho foi verificar a influência da adição de resíduos de poli (tereftalato de etileno) - PET - sobre a resistência mecânica em concreto de cimento Portland. O PET foi utilizado no formato encontrado em indústria de reciclagem de embalagens. Os resíduos foram utilizados como substitutos de parte dos agregados do concreto e, para cada um dos resíduos, foram preparados quatro traços (10%, 20%, 30% e 40%, em volume). Para a preparação dos tra� (mais) �os foi utilizado cimento Portland de Alta Resistência Inicial (CPV - ARI) fornecido pela Votoran. A partir de cada uma das misturas obtidas foram confeccionados quinze corpos-de-prova em formato cilíndrico conforme a norma NBR 5738. Foram preparados também corpos-de-prova sem substituição de agregados que serviram como material de referência. Os ensaios de compressão foram realizados de acordo com a norma NBR 5739, nas idades de um, três e sete dias e, em cada uma destas idades, foram testados cinco corpos-de-prova de cada traço. Para todos os traços obtidos e, em todas as idades das amostras ensaiadas, pode-se notar uma tendência de redução da resistência mecânica com o aumento da fração volumétrica de substituição de agregados. O maior valor de resistência à compressão axial com a idade de sete dias foi apresentado pelo traço sem substituição de agregados (15,38 MPa), e o menor valor, para a mesma idade, foi apresentado pelo traço com 40 % de substituição de agregados por resíduos de PET (1,94 MPa). Resumo em inglês This work aims to verify the influence of poly (ethylene terephthalate) - PET - wastes additions on the concrete mechanical strength. The concrete used was prepared with a Portland cement. The PET was used in the as received shape from the packing recycling industry. The wastes were used as substitutes of concrete aggregates. For each waste type four mixtures (10, 20, 30 and 40 vol-%) were prepared. In order to prepare mixtures, high early strength Portland cement (CPV - (mais) ARI) was used, supplied by the Votoran Company. From each mixture obtained fifteen cylindrical shaped samples were prepared. The samples were prepared in accordance to the NBR 5738 Brazilian Standard. As reference materials, samples without wastes were also prepared. Mechanical strength tests were performed according to the Brazilian Standard NBR 5739. In this case, the following ages were tested: one, three and seven days. For each age, five samples were tested from each mixture prepared. For all mixtures obtained and for each sample age tested, a reduction in the mechanical strength occurred as the PET waste additions were increased. The highest mechanical strength value, 15.38 MPa, was obtained using sample with seven days age and mixture without aggregates. The lowest strength value, 1.94 MPa, was also obtained using sample with seven days age but with 40 vol-% PET waste addition.

Scientific Electronic Library Online (Portuguese)

14

Aspectos morfológicos e hemodinâmicos do baço em indivíduos normais: estudo por ultra-som Doppler/ Morphological and hemodynamic features of the spleen in normal subjects: a Doppler ultrasound study

Jannini, Denise Said; Oliveira, Ilka Regina Souza de; Widman, Azzo; Ianhez, Luiz Estevam; Cerri, Giovanni Guido
2003-08-01

Resumo em português ANTECEDENTES: A diversidade de técnicas de mensuração esplênica pelo ultra-som Doppler (US Doppler), a falta de valores biométricos e dopplervelocimétricos dificultam a avaliação deste órgão e de suas características hemodinâmicas. OBJETIVO: Estabelecer padrões biométricos e hemodinâmicos por US-Doppler em indivíduos adultos sadios. MATERIAIS E MÉTODOS: Estudo prospectivo de 44 indivíduos sadios, sendo 19 do sexo masculino e 25 do sexo feminino, na faixa (mais) etária de 23 a 60 anos (37,4 ± 9,6). Morfometria (US modo-B): baço: eixos longitudinal (L), transversal (T) e ântero-posterior (AP); diâmetro da artéria esplênica (DAE) e diâmetro da veia esplênica (DVE). Índices morfométricos do baço: uniplanar (IBU), biplanar (IBB) e volume esplênico (VE). Dopplervelocimetria (US Doppler): a) artéria esplênica: velocidade de pico sistólico (VPS), média das velocidades máximas de fluxo (TAMax); índices de impedância vascular: índice de resistividade (IR); índice de pulsatilidade (IP); b) veia esplênica: média das velocidades máximas de fluxo (TAMax). RESULTADOS: Morfometria: L = 9,3 ± 1,3 cm; T= 3,9 ± 0,7 cm; AP = 8,4 ± 1,2 cm; DAE = 0,3 ± 0,07 cm; DVE: 0,5 ± 0,12 cm. Índices morfométricos do baço: IBU = 33,5 ± 9,9; IBB = 36,7 ± 10,3; VE = 164,3 ± 62,9 cm³. Dopplervelocimetria: a) artéria esplênica: VPS = 59,8 ± 23,6 cm/s; TAMax = 40,2 ± 15,9 cm/s; IP = 0,86 ± 0,30; IR = 0,55 ± 0,09; b) veia esplênica: TAMax = 16,8 ± 8,3 cm/s. CONCLUSÃO: Relato de valores biométricos e dopplervelocimétricos do baço em indivíduos sadios. Resumo em inglês BACKGROUND: The diversity of existing techniques for the measurement of the spleen using Doppler ultrasound (Doppler-US) as well as the lack of biometrical and Doppler velocimetry reference values make the evaluation of this organ and its hemodynamics quite difficult. OBJECTIVES: To establish biometrical and hemodynamics Doppler-US standard values for healthy adult individuals. MATERIALS AND METHODS: This is a prospective study involving 44 healthy individuals (19 males a (mais) nd 25 females) with mean age of 37.4 ± 9.6 years (23-60 years). Morphometry (US-B mode): spleen: longitudinal (L), transversal (T) and anteroposterior (AP) axes; splenic artery diameter (AD) and splenic vein diameter (VD). Morphometrical spleen indexes: uniplanar (UI), biplanar (BI) and the splenic volume (SV). Doppler velocimetry (US-Doppler): a) splenic artery: systolic peak velocity (SPV), mean of the highest flow speeds (TAMax); pulsability index (PI) and vascular impedance resistivity index(RI); b) splenic vein: mean of the highest flow speeds (TAMax). RESULTS: Morphometry: L = 9.3 ± 1.3 cm; T= 3.9 ± 0.7 cm; AP = 8.4 ± 1.2 cm; AD = 0.3 ± 0.07 cm; VD: 0.5 ± 0.12 cm. Morphometrical spleen indexes: UI = 33.5 ± 9.9; BI = 36.7 ± 10.3; SV = 164.3 ± 62.9 cm³. Doppler velocimetry: a) splenic artery: SPV = 59.8 ± 23.6 cm/s; TAMax = 40.2 ± 15.9 cm/s; PI = 0.86 ± 0.30; RI = 0.55 ± 0.09; b) splenic vein: TAMax = 16.8 ± 8.3 cm/s. CONCLUSION: Report of biometrical and Doppler velocimetry standard values of the spleen in healthy individuals.

Scientific Electronic Library Online (Portuguese)

15

A correlação de métodos dexa e cdexa em absortimetria mineral óssea/ The correlation between DEXA and CDEXA methods in bone mineral absorptiometry

Defavori, Cláudio Gilberto; Sarriés, Gabriel Adrian
2007-06-01

Resumo em português OBJETIVO: Estudar a intercambiabilidade dos resultados de densidade mineral óssea entre máquinas de absortimetria de raios-x em duas energias (DEXA) Hologic® e de absortimetria computadorizada de raios-x convencionais em duas energias (CDEXA) Cromox®. MATERIAIS E MÉTODOS: Para 38 casos de quadril e 31 casos de coluna lombar avaliados em 43 pacientes atendidos em um centro de diagnóstico por imagem, medidas de densidade mineral óssea foram realizadas em ambas as má (mais) quinas. A máquina Cromox® foi calibrada usando-se o phantom Cromox® de referência para absortimetria óssea. RESULTADOS: Forte correlação entre os resultados obtidos nas duas máquinas foi encontrada para cada sítio do esqueleto. O coeficiente de correlação linear medido para o colo femoral direito foi r = 0,920, p 0,95. Para ambos os sítios, a diferença média aritmética em Tscore entre as máquinas é pequena, menor que a menor variação significativa. Resumo em inglês OBJECTIVE: To study the interchangeability of the bone mineral density results between Hologic® dual energy x-ray absorptiometry (DEXA) and Cromox® computed dual energy conventional x-ray absorptiometry (CDEXA) equipments. MATERIALS AND METHODS: Thirty-eight femoral necks and 31 lumbar spines of 43 patients underwent bone mineral density measured by both equipments in a diagnostic imaging center. The Cromox® equipment was calibrated with a reference Cromox® phantom fo (mais) r bone absorptiometry. RESULTS: A strong correlation between results obtained from the two devices was found for each skeletal site. The linear correlation coefficient measured for the right femoral neck was r = 0.920, p 0.95. For both sites, the arithmetic mean difference in Tscore between devices is low - least than the lowest significant variance.

Scientific Electronic Library Online (Portuguese)

16

A (des)informação sobre medicamentos: o duplo padrão de conduta das empresas farmacêuticas/ (Mis)information on drugs: the double standard practiced by pharmaceutical companies

Barros, José Augusto C.
2000-06-01

Resumo em português Diferentes fatores foram identificados como exercendo influência sobre o comportamento dos prescritores de medicamentos. Estudos realizados enfatizam o lugar proeminente ocupado pelas fontes de informação disponíveis para os médicos, muitos deles realçando a influência das estratégias de mercadização. Entre elas, pode-se citar os anúncios em revistas médicas, propagandistas, amostras grátis, folhetos, brindes, etc. A presente pesquisa teve o propósito de det (mais) ectar as informações presentes no Dicionário de Especialidades Farmacêuticas (DEF) sobre as 44 especialidades farmacêuticas mais vendidas, tendo como parâmetro critérios da OMS para comporem material informativo oferecido aos médicos. Essas informações foram, igualmente, comparadas, para os mesmos produtos, com aquelas presentes em dois manuais de uso habitual nos Estados Unidos: Physicians' Desk Reference (PDR) e Drug Information for the Health Care Professional (USP-DI). Os resultados demonstraram ausência, no manual brasileiro de contra-indicações, reações adversas, interações, o que permite desconfiar da qualidade da prescrição. Resumo em inglês Different factors have been identified as influencing drug prescribers. Some studies emphasize the role played by sources of information available to physicians. Reports have been published on the influence of marketing strategies on these health professionals. Such strategies include advertisements in medical journals, sales representatives, free samples, leaflets, distribution of gifts and prizes, etc. The research reported here aimed to identify information provided by (mais) a commonly used Brazilian prescription handbook, the Dicionário de Especialidades Farmacêuticas (DEF), in relation to the 44 most frequently sold pharmaceutical products in Brazil, using as parameters the WHO guidelines for information to be included in informative materials offered to physicians. The information was then compared to that included in the PDR (Physicians' Desk Reference) and USP-DI (Drug Information for the Health Care Professional) used by prescribers in the United States. The results showed lack of data in the Brazilian publication (contraindications, side effects, drug interaction), suggesting lack of reliability in prescription quality and thus in the ultimate utilization of drugs.

Scientific Electronic Library Online (Portuguese)

17

A (des)informação sobre medicamentos: o duplo padrão de conduta das empresas farmacêuticas/ (Mis)information on drugs: the double standard practiced by pharmaceutical companies

Barros, José Augusto C.
2000-06-01

Resumo em português Diferentes fatores foram identificados como exercendo influência sobre o comportamento dos prescritores de medicamentos. Estudos realizados enfatizam o lugar proeminente ocupado pelas fontes de informação disponíveis para os médicos, muitos deles realçando a influência das estratégias de mercadização. Entre elas, pode-se citar os anúncios em revistas médicas, propagandistas, amostras grátis, folhetos, brindes, etc. A presente pesquisa teve o propósito de det (mais) ectar as informações presentes no Dicionário de Especialidades Farmacêuticas (DEF) sobre as 44 especialidades farmacêuticas mais vendidas, tendo como parâmetro critérios da OMS para comporem material informativo oferecido aos médicos. Essas informações foram, igualmente, comparadas, para os mesmos produtos, com aquelas presentes em dois manuais de uso habitual nos Estados Unidos: Physicians' Desk Reference (PDR) e Drug Information for the Health Care Professional (USP-DI). Os resultados demonstraram ausência, no manual brasileiro de contra-indicações, reações adversas, interações, o que permite desconfiar da qualidade da prescrição. Resumo em inglês Different factors have been identified as influencing drug prescribers. Some studies emphasize the role played by sources of information available to physicians. Reports have been published on the influence of marketing strategies on these health professionals. Such strategies include advertisements in medical journals, sales representatives, free samples, leaflets, distribution of gifts and prizes, etc. The research reported here aimed to identify information provided by (mais) a commonly used Brazilian prescription handbook, the Dicionário de Especialidades Farmacêuticas (DEF), in relation to the 44 most frequently sold pharmaceutical products in Brazil, using as parameters the WHO guidelines for information to be included in informative materials offered to physicians. The information was then compared to that included in the PDR (Physicians' Desk Reference) and USP-DI (Drug Information for the Health Care Professional) used by prescribers in the United States. The results showed lack of data in the Brazilian publication (contraindications, side effects, drug interaction), suggesting lack of reliability in prescription quality and thus in the ultimate utilization of drugs.

Scientific Electronic Library Online (Portuguese)