Sample records for radiation dosimetry
from WorldWideScience.org

Sample records 1 - 7 shown.



1

Dosimetria esporular: Bacillus subtilis TKJ6312 como biossensor de radiação solar biologicamente ativa/ Spore dosimetry: Bacillus subtilis TKJ6312 as biosensor of biologically effective solar radiation

Rosa, Marcelo Barcellos da; Rampelotto, Pabulo Henrique; Schuch, Nelson Jorge; Schuch, André Passaglia; Munakata, Nobuo
2009-01-01

Resumo em inglês Since 2000, spore dosimetry and spectral photometry have been performed in parallel at the Southern Space Observatory, São Martinho da Serra (Southern Brazil). A comparative study involving data from Punta Arenas - Chile (53.2º S), São Martinho da Serra (29.5º S), Padang - Indonesia (0.9ºS), Brussels - Belgium (50.9º N) and Kiyotake - Japan (31.9º N) from 2000 to 2006 is presented. The Spore Inactivation Doses presented the higher values in summer (973 ± 73 for Pu (mais) nta Arenas and 4,369 ± 202 for São Martinho da Serra, as well 1,402 ± 170 and 3,400 ± 1,674 for Brussels and Kiyotake, respectively). The simplicity, robustness and high resistance of bacterial spores makes the biosensor an potential biological tool for UV-B monitoring.

Scientific Electronic Library Online (Portuguese)

2

Termoluminescência de materiais e sua aplicação em dosimetria da radiação/ Thermoluminescence of materials and its application on radiation dosimetry

Campos, Letícia L.
1998-12-01

Resumo em português A dosimetria termoluminescente é uma ferramenta versátil para a avaliação da dose de radiação ionizante. A grande variedade de materiais cerâmicos e suas diferentes formas físicas permitem a determinação da qualidade da radiação em um intervalo de doses de m Gy a kGy. Umas das maiores vantagens dos dosímetros TL são as suas pequenas dimensões e o fato de não necessitarem de cabos ou equipamentos auxiliares durante a medida da dose. Como conseqüência diss (mais) o, eles são adequados para um grande número de aplicações. Esse artigo tem como objetivo apresentar uma breve revisão dos princípios básicos, dos cálculos teóricos da TL, o modelo simplificado de termoluminescência, algumas aplicações na dosimetria das radiações ionizantes e os trabalhos desenvolvidos no IPEN nessa área. Resumo em inglês Thermoluminescence dosimetry is a versatile tool for the assessment of dose from ionising radiation. The wide variety of TLD ceramic materials and their different physical forms allow the determination of different radiations qualities at dose levels from m Gy to kGy. Major advantages of TL dosimeters are their small physical size and that no cables or auxiliary equipment is required during the dose measurement. This makes them well suited for a wide range of applications (mais) . This article aims to present a short review of basic principles of, and a theoretical approach to, thermoluminescence, the usual basic thermoluminescence model, some applications to the dosimetry of ionising radiations and the research developed at IPEN in this area.

Scientific Electronic Library Online (Portuguese)

3

Verificação das doses de radiação absorvidas durante a técnica de irradiação de corpo inteiro nos transplantes de medula óssea, por meio de dosímetros termoluminescentes/ Measurement of absorbed radiation doses during whole body irradiation for bone marrow transplants using thermoluminescent dosimeters

Giordani, Adelmo José; Segreto, Helena Regina Comodo; Segreto, Roberto Araújo; Medeiros, Regina Bitelli; Oliveira, José Salvador R. de
2004-10-01

Resumo em português OBJETIVO: Avaliar a precisão das doses de radiação absorvidas na terapia de transplantes de medula óssea durante a técnica de irradiação de corpo inteiro. MATERIAIS E MÉTODOS: Utilizaram-se 200 pastilhas de sulfato de cálcio com disprósio compactado com teflon (CaSO4 + teflon), calibradas no ar e no "phantom", selecionadas aleatoriamente e dispostas em grupos de cinco no corpo dos pacientes. As leituras dosimétricas foram efetuadas pela leitora Harshaw 4000A. N (mais) ove pacientes foram irradiados no corpo inteiro em paralelos e em opostos laterais, utilizando-se unidade de cobalto-60, modelo Alcion II, com taxa de dose de 0,80 Gy/min a 80,5 cm, {campo (10 × 10) cm²}. A dosimetria dessa unidade foi realizada com dosímetro Victoreen 500. Para a determinação da dose média em cada ponto avaliado usaram-se os fatores individuais de calibração das pastilhas no ar e no "phantom", colocando-se um "build up" de 2 mm para superficializar a dose à distância de 300 cm. RESULTADOS: Em 70% dos pacientes obteve-se variação de dose menor que 5% e em 30% dos pacientes essa variação foi inferior a 10%, quando comparados os valores medidos com aqueles calculados em cada ponto. Na cabeça ocorre absorção, em média, de 14% da dose administrada, e nos pulmões, acréscimo de 2% na dose administrada. Nos pacientes com distância látero-lateral maior que 35 cm as variações entre as doses calculadas e medidas podem chegar a 30% da dose desejada, sem o uso de filtros compensadores. CONCLUSÃO: Os valores medidos das doses absorvidas nos diversos pontos anatômicos, comparados aos valores desejados (teóricos), apresentam tolerância de ±10%, considerando-se as diferenças anatômicas existentes, quando utilizados os fatores de calibração individuais das pastilhas. Resumo em inglês OBJECTIVE: To evaluate the precision of the absorbed radiation doses in bone marrow transplant therapy during whole body irradiation. MATERIALS AND METHODS: Two-hundred CaSO4:Dy + teflon tablets were calibrated in air and in "phantom". These tablets were randomly selected and divided in groups of five in the patients' body. The dosimetric readings were obtained using a Harshaw 4000A reader. Nine patients had their entire bodies irradiated in parallel and opposite laterals (mais) in a cobalt-60 Alcion II model, with a dose rate of 0.80 Gy/min at 80.5 cm, {(10 × 10) cm² field}. The dosimetry of this unit was performed using a Victoreen 500 dosimeter. For the determination of the mean dose at each point evaluated, the individual values of the tablets calibrated in air or "phantom" were used, resulting in a build up of 2 mm to superficialize the dose at a distance of 300 cm. RESULTS: In 70% of the patients a variation of less than 5% in the dose was obtained. In 30% of the patients this variation was less than 10%, when values obtained were compared to the values calculated at each point. A mean absorption of 14% was seen in the head, and an increase of 2% of the administered dose was seen in the lungs. In patients with latero-lateral distance greater than 35 cm the variation between the calculated doses and the measured doses reached 30% of the desired dose, without the use of compensation filters. CONCLUSION: The measured values of the absorbed doses at the various anatomic points compared to the desired doses (theoretic) presented a tolerance of ± 10%, considering the existent anatomical differences and when using the individual calibration factors of the tablets.

Scientific Electronic Library Online (Portuguese)

4

Recomendações para se evitar grandes erros de dose em tratamentos radioterapêuticos/ Recommendations to avoid gross errors of dose in radiotherapeutic treatments

Souza, Cleber Nogueira de; Monti, Carlos Roberto; Sibata, Cláudio Hissao
2001-02-01

Resumo em português Erros humanos são uma importante fonte de falhas em todos os passos do planejamento e do tratamento radioterapêutico. Com o objetivo de reduzir este grau de incerteza, várias organizações especializadas recomendam minuciosos programas de garantia da qualidade. No Brasil, programas deste tipo vêm tendo sua exigência intensificada, e a maioria dos serviços de radioterapia vem se orientando neste sentido, tanto em relação aos equipamentos de radiação e dosimetria (mais) , quanto em relação à verificação dos cálculos de dose em pacientes e das revisões das fichas de planejamento. Como uma contribuição a este esforço de qualidade, apresentam-se algumas recomendações para se evitar falhas de tratamento devidas a erros na dose de radiação recebida pelo paciente, como redundância nas verificações dos cálculos feitos manualmente ou por computador, e, também, a verificação da dose acumulada para cada paciente sob tratamento, semanalmente, além de se evitar a possibilidade de acesso a qualquer sistema de segurança do equipamento ao pessoal técnico treinado para apenas o operar. Além disso, deve-se considerar a possibilidade de se empregar um sistema computadorizado de verificação e registro do tratamento, dessa maneira prevenindo-se erros durante a aplicação diária devidos à seleção indevida dos diferentes parâmetros do tratamento. Reportam-se quatro incidentes radioativos recentes ocorridos no mundo, com injúrias em pacientes, e algumas ocorrências de erros grandes de dose. Resumo em inglês Human mistakes are an important source of errors in radiotherapy and may occur at every step of the radiotherapeutic planning and treatment. To reduce this level of uncertainties, several specialized organizations have recommended a comprehensive quality assurance program. In Brazil, the requirement for these programs has been strongly stressed, and most radiotherapy services have pursued this goal regarding radiation units and dosimetry equipment, as well as the verifica (mais) tion of the calculations of the patient's dose and the revision of the plan charts. As a contribution to the improvement of quality control, we present some recommendations to avoid failure of treatment due to error in the delivered dose, such as redundant check of the manual or computer calculations, weekly check of the total dose for each patient, and prevention of inadvertent access to any safety system of the equipment by any staff member that is only supposed to operate the machine. Moreover, the use of a computerized treatment record and verification system should be considered in order to eliminate errors due to incorrect selection of the treatment parameters, in a daily basis. We report four radioactive incidents with patient injuries occurred throughout the world and some gross errors of dose.

Scientific Electronic Library Online (Portuguese)

5

Radioiodoterapia do carcinoma diferenciado da tireoide: impacto radiológico da liberação hospitalar de pacientes com atividades entre 100 e 150 mCi de iodo-131/ Radioiodine therapy of differentiated thyroid cancer: radiologic impact of out-patient treatment with 100 to 150 mCi Iodine-131 activities

Sapienza, Marcelo Tatit; Willegaignon, José; Ono, Carla Rachel; Watanabe, Tomoco; Guimarães, Maria Inês Calil Cury; Gutterres, Ricardo Fraga; Maréchal, Maria Helena da Hora; Buchpiguel, Carlos Alberto
2009-04-01

Resumo em português OBJETIVO: Determinar exposições decorrentes da radioiodoterapia ambulatorial do carcinoma diferenciado da tireoide (CDT) sobre os familiares dos pacientes e o meio ambiente. MÉTODOS: Administraram-se 100 a 150 mCi de (131I)NaI para tratamento ambulatorial de 20 pacientes com CDT. Monitorizaram-se com dosímetros termoluminescentes as doses de radiação recebidas por familiares (n = 27) e potenciais de dose nas residências. Também foram monitorizadas contaminação d (mais) e superfície e rejeitos radioativos. RESULTADOS: Registraram-se doses Resumo em inglês PURPOSE:To evaluate exposure and dosimetry to family members and environment due to outpatient radioiodine therapy of differentiated thyroid carcinoma. METHODS: Twenty patients were treated with 100-150mCi of iodine-131 on an out-patient basis. Family members dosimetry (n = 27) and potential doses inside the house were measured with thermoluminescent dosimeters. Surface contamination and radioactive wastes were also monitored. RESULTS: Less than 1.0 mSv doses were found i (mais) n 26 co-habitants and 2.8 mSv in a single case (inferior to the acceptable value of 5.0 mSv/procedure). Potential doses in the houses were inferior to 0.25 mSv, excluding the patients bedroom (mean value = 0.69 mSv). Surface contamination (mean = 4.2 Bq.cm-2) were below clearance levels. Radioactive wastes generated had a volume of 2.5 liters and a total activity estimated in 90 µCi, with a calculated exposure close to the background radiation levels. CONCLUSIONS: No radiological impact was detected after iodine therapy with 100-150 mCi on an out-patient basis followed by experienced professionals.

Scientific Electronic Library Online (Portuguese)

6

Avaliação da exposição ocupacional em procedimentos de hemodinâmica/ Evaluation of occupational exposure in hemodynamic procedures

Scremin, Silvia C. Gusso; Schelin, Hugo R.; Tilly Jr., João G.
2006-04-01

Resumo em português OBJETIVO: Avaliar a dose efetiva recebida pelos trabalhadores envolvidos na realização de procedimentos de hemodinâmica, de forma a estabelecer parâmetros comparativos entre os dados obtidos com uma câmara de ionização e pelos dosímetros usados para monitoração individual. MATERIAIS E MÉTODOS: A avaliação foi desenvolvida em um serviço de hemodinâmica, sendo que os testes constaram da medida do taxa de kerma no ar no ambiente real de trabalho, na posição (mais) ocupada por médicos e enfermeiros, com e sem a utilização de barreira plumbífera de proteção. Foi levado em consideração o número de exames realizados no serviço e foram selecionados as projeções e parâmetros radiográficos mais utilizados. Para a estimativa da dose efetiva foram utilizados fatores de conversão encontrados na literatura. RESULTADOS: Os valores encontrados em dose efetiva e de dosimetria são consistentes. Observou-se, ainda, que o uso da barreira protetora plumbífera reduz em até 97% a dose recebida pelo profissional, devendo esta ser utilizada na rotina de exames. CONCLUSÃO: Os valores apresentados são representativos, não podendo ser assumidos como reprodução das condições de monitoração individual, mas são válidos para comparações e orientação na otimização das doses. Resumo em inglês OBJECTIVE: This study aims to evaluate the effective ionizing radiation dose received by staff involved in interventional vascular procedures to establish parameters for comparison between the data obtained with an ionization chamber and with the dosimeters used for individual monitoring. MATERIALS AND METHODS: The evaluation was performed in a cardiac catheter laboratory and air kerma rate was measured in a real working environment, in the positions occupied by physician (mais) s and nurses, with and without the lead glass shield. The number of tests performed in the laboratory was taken into consideration and most common projections and radiographic parameters were selected. Conversion factors founded in the literature were applied for the effective dose estimation. RESULTS: The values found in the effective dose and in the dosimetry report were rather consistent. Additionally, it was observed that the use of the lead glass shield reduces in up to 97% the doses received by the professional and therefore it must be routinely used. CONCLUSION: The reported values are representative but cannot be assumed as a reproduction of individual monitoring conditions, although they are valid for comparison purposes and as a guidance for dosing optimization.

Scientific Electronic Library Online (Portuguese)

7

Análise da distribuição espacial de dose absorvida em próton terapia ocular/ Spatial distribution analysis of absorbed dose in ocular proton radiation therapy

Christóvão, Marília Tavares; Campos, Tarcísio Passos Ribeiro de
2010-08-01

Resumo em português OBJETIVO: Propõe-se avaliar os perfis de dose em profundidade e as distribuições espaciais de dose para protocolos de radioterapia ocular por prótons, a partir de simulações computacionais em código nuclear e modelo de olho discretizado em voxels. MATERIAIS E MÉTODOS: As ferramentas computacionais empregadas foram o código Geant4 (GEometry ANd Tracking) Toolkit e o SISCODES (Sistema Computacional para Dosimetria em Radioterapia). O Geant4 é um pacote de software (mais) livre, utilizado para simular a passagem de partículas nucleares com carga elétrica através da matéria, pelo método de Monte Carlo. Foram executadas simulações computacionais reprodutivas de radioterapia por próton baseada em instalações pré-existentes. RESULTADOS: Os dados das simulações foram integrados ao modelo de olho através do código SISCODES, para geração das distribuições espaciais de doses. Perfis de dose em profundidade reproduzindo o pico de Bragg puro e modulado são apresentados. Importantes aspectos do planejamento radioterápico com prótons são abordados, como material absorvedor, modulação, dimensões do colimador, energia incidente do próton e produção de isodoses. CONCLUSÃO: Conclui-se que a terapia por prótons, quando adequadamente modulada e direcionada, pode reproduzir condições ideais de deposição de dose em neoplasias oculares. Resumo em inglês OBJECTIVE: The present study proposes the evaluation of the depth-dose profiles and the spatial distribution of radiation dose for ocular proton beam radiotherapy protocols, based on computer simulations in nuclear codes and an eye model discretized into voxels. MATERIALS AND METHODS: The employed computational tools were Geant4 (GEometry ANd Tracking) Toolkit and SISCODES (Sistema Computacional para Dosimetria em Radioterapia - Computer System for Dosimetry in Radiothera (mais) py). Geant4 is a toolkit for simulating the passage of particles through the matter, based on Monte Carlo method. Computer simulations of proton therapy were performed based on preexisting facilities. RESULTS: Simulation data were integrated into SISCODES on the eye's model generating spatial dose distributions. Dose depth profiles reproducing the pure and modulated Bragg peaks are presented. Relevant aspects of proton beam radiotherapy planning are considered such as material absorber, modulation, collimator dimensions, incident proton energy and isodose generation. CONCLUSION: The conclusion is that proton therapy when properly modulated and directed can reproduce the ideal conditions for the dose deposition in the treatment of ocular tumors.

Scientific Electronic Library Online (Portuguese)