Sample records for pulsed irradiation
from WorldWideScience.org

Sample records 1 - 5 shown.



1

Os efeitos do ultra-som terapêutico nas lesões por esmagamento do nervo ciático de ratos: análise funcional da marcha/ Effects of therapeutic ultrasound on injuries due to crushing of the sciatic nerve in rats: functional evaluation of gait

Monte-Raso, VV; Barbieri, CH; Mazzer, N; Fazan, VPS
2006-01-01

Resumo em português INTRODUÇÃO: Os efeitos da irradiação ultra-sônica terapêutica na regeneração de nervos periféricos não são ainda bem conhecidos, particularmente no que se refere à recuperação funcional. Por outro lado, o método da avaliação da impressão da pegada do rato para medida do Índice Funcional do Ciático (IFC) já está bem sistematizado, mostrando estreita correlação com a regeneração morfológica do nervo ciático lesado em ratos. Objetivos: Analisar a (mais) influência do ultra-som terapêutico na regeneração do nervo ciático de ratos submetido a esmagamento controlado. Material e métodos: Foram empregados 20 ratos da linhagem Wistar com peso corporal médio de 300 g, divididos em dois grupos conforme o tipo de procedimento realizado: 1) somente esmagamento (n=10); 2) esmagamento e irradiação com ultra-som (n=10). Sob anestesia geral, o nervo ciático era exposto na coxa direita do animal e esmagado com um dispositivo especialmente confeccionado para essa finalidade, com uma carga fixa de 15 Kg por 10 minutos, num segmento de 5 mm proximal à sua bifurcação. A irradiação ultra-sônica pulsada de baixa intensidade (1:5, 0,4 W/cm², 1 MHz, duração 2 minutos) era iniciada já no primeiro dia pós-operatório e realizada por dez dias consecutivos. As impressões das pegadas dos animais, obtidas semanalmente, da primeira à terceira semana pós-operatória, em passarela específica para essa finalidade, foram avaliadas por meio de um programa de computador igualmente específico, segundo método pré-existente já testado em trabalhos anteriores, com cálculo automático do IFC. Resultados: O IFC aumentou progressivamente nos dois grupos, passando no Grupo 2 de 101 na primeira semana, para 59,21 na segunda e 26,68 na terceira, o que significou uma melhora de 73% entre a primeira e a última medida. No Grupo 1, o IFC subiu de 98,2 na primeira semana, para 79,5 na segunda e 44 na terceira, o que significou uma melhora de 55% entre a primeira medida e a última. As diferenças entre os grupos foram significativas no 14º e no 21º dia (p=0,02 e p=0,002, respectivamente). Conclusão: O ultra-som terapêutico de baixa intensidade acelerou a regeneração do nervo ciático do rato, demonstrável com maior significância no 21º dia pós-operatório. Resumo em inglês Background: The effects of therapeutic ultrasound irradiation on peripheral nerve regeneration are not well known, particularly regarding functional recovery. However, in rats, footprint evaluation is a well-systematized method for measuring the Sciatic Functional Index (SFI), showing close correlation with morphological regeneration of damaged sciatic nerves. Objective: To analyze the influence of therapeutic ultrasound on sciatic nerve regeneration in rats subjected to (mais) controlled crushing. Method: 20 Wistar rats (mean body weight: 300 g) were divided into two experimental groups: 1) crushing only (n=10); 2) crushing followed by ultrasound irradiation (n=10). Under general anesthesia, a 5-mm segment of sciatic nerve proximal to its bifurcation in the right thigh was exposed and crushed with constant loading of 15 kg for 10 minutes, using a specially-built device. Low-intensity pulsed ultrasound irradiation (1:5, 0.4 W/cm², 1 MHz, 2 minutes) was started on the first postoperative day and administered for ten consecutive days. Footprints were obtained weekly (postoperative weeks 13) using a specially-designed walkway, and evaluated using specifically-developed software, according to a previously-tested method, with automatic SFI calculation. Results: The SFI progressively increased in both groups: Group 2, from 101 in the first week to 59.21 (second) and 26.68 (third), i.e. 73% improvement overall; Group 1, from 98.2 (first) to 79.5 (second) and 44 (third), i.e. 55% improvement overall. The differences between the groups were significant for the second and third weeks (p=0.02 and p=0.002, respectively). Conclusion: Low-intensity therapeutic ultrasound accelerates the regeneration of crushed sciatic nerves in rats, as demonstrated by its functional recovery.

Scientific Electronic Library Online (Portuguese)

2

Mensuração de área de cicatrização por planimetria após aplicação do ultra-som de baixa intensidade em pele de rato/ Measurement of healing area using planimetry after applying low-intensity ultrasound to the skin of rats

Ferreira, AS; Barbieri, CH; Mazzer, N; Campos, AD; Mendonça, AC
2008-10-01

Resumo em português CONTEXTUALIZAÇÃO: A planimetria é um método utilizado para avaliar a evolução da cicatrização de feridas. A planimetria computacional é um método ainda em experimentação, mas cujas vantagens têm sido demonstradas em várias investigações. OBJETIVOS: Avaliar os efeitos do ultra-som pulsado de baixa intensidade sobre a cicatrização de lesão cutânea produzida na região dorsal de ratos, por meio da planimetria computacional. MATERIAIS E MÉTODOS: Utilizou- (mais) se 60 ratos machos Wistar (peso médio de 300g) divididos em dois grupos com 30 animais cada, de acordo com o tratamento: 1) irradiação simulada (controle); 2) irradiação efetiva (Freqüência fundamental de 1,5MHz, freqüência de repetição de pulsos de 1KHz, largura de pulso de 200µs, intensidade de 30mW/cm² SATA, dez minutos de aplicação em dias alternados). Cada grupo foi subdividido em três grupos, de acordo com o período de irradiação ultra-sônica, de três, sete e 14 dias, respectivamente, e a cicatrização foi avaliada por meio da planimetria, um decalque da lesão sendo obtido em papel especial, digitalizado e medido ao computador por meio de um programa gráfico. Análise estatística pelo método não-paramétrico de Mann-Whitney. RESULTADOS: Houve aumento significante (p Resumo em inglês BACKGROUND: Planimetry is a method used to evaluate the progression of skin wound healing. Computerized planimetry is still an experimental method, but its advantages have been demonstrated in several investigations. OBJECTIVE: To evaluate the effects of low-intensity pulsed ultrasound on the healing of a skin lesion produced on the dorsal region of rats, by means of computerized planimetry. METHODS: Sixty male Wistar rats of mean weight 300g were used. They were divided (mais) into two groups according to the treatment applied: 1) simulated irradiation (control); 2) effective irradiation (fundamental frequency 1.5MHz, pulse repetition frequency 1KHz, pulse width 200µs, SATA intensity 30mW/cm² and application for ten minutes on alternate days). Each group was divided into three subgroups according to the length of time for which ultrasound irradiation was applied of three, seven and 14 days, respectively, and healing was evaluated by means of planimetry; a tracing of the wound was obtained on special paper and this was digitized and measured by means of a graphing software. Statistical analysis was performed using the Mann-Whitney non-parametric method. RESULTS: The healed area was significantly greater (p

Scientific Electronic Library Online (Portuguese)

3

Efeitos do ultra-som pulsado de baixa intensidade sobre a cicatrização por segunda intenção de lesões cutâneas totais em ratos/ Effects of low-power pulsed ultrasound on second-intention healing of total skin injuries in rats

Mendonça, Adriana Clemente; Ferreira, Adriana da Silva; Barbieri, Claudio Henrique; Thomazine, José Antônio; Mazzer, Nilton
2006-01-01

Resumo em português Avaliamos os efeitos do ultra-som pulsado de baixa intensidade sobre a cicatrização de lesão cutânea produzida na região dorsal de ratos. Utilizamos 60 ratos machos (Wistar, peso médio de 300g) divididos em dois grupos, sendo: 1) irradiação simulada; 2) irradiação efetiva (freqüência fundamental de 1,5MHz, freqüência de repetição de pulsos de 1KHz, largura de pulso de 200 µs, intensidade de 30mW/cm² -SATA, 10 minutos de aplicação em dias alternados). E (mais) stes foram subdivididos em subgrupos, de acordo com o tempo de avaliação da lesão, de 3, 7 e 14 dias, e a cicatrização foi avaliada através de análises planimétrica e histo-morfométrica. Aumento significante (p Resumo em inglês We evaluated the effects of low-power pulsed ultrasound on skin injury healing at dorsal region of rats. Sixty male rats were used (Wistar, mean weight: 300 g) divided into two groups, namely: 1) simulated irradiation; 2) effective irradiation (basic rate of 1.5MHz, pulse cycle rate of 1KHz, pulse width of 200 µs, power of 30mW/cm2 -SATA, 10 minutes of application in alternate days). These were further divided into subgroups, according to the time of injury assessment, a (mais) s 3, 7, and 14 days, and healing was assessed by planimetrical and histomorphometrical analysis. A significant increase (p

Scientific Electronic Library Online (Portuguese)

4

Análise micromorfológica de esmalte e dentina expostos ao laser de Nd: YAG em regime de picossegundos/ Micro-morphological analisys of enamel and dentin exposed to picosecond-pulsed Nd: YAG laser

Lizarelli, Rosane de Fátima Zanirato; Bagnato, Vanderlei Salvador
2002-09-01

Resumo em português A eficiência da ablação com laser através de um regime de picossegundos minimiza a destruição do material adjacente devido à formação de plasma e ataque. Isso previne a geração excessiva de ondas de choque e promove uma considerável diminuição nos efeitos mecânicos. Nesse estudo foi utilizado um laser de Nd:YAG em picossegundo "Q-switched" e "mode-locked" (Antares 76-s, Coherent, Palo Alto, CA), três molares humanos recém-extraídos e foram realizados 15 (mais) microcavidades em esmalte e 9 em dentina. Os parâmetros para irradiar o esmalte seguiram uma freqüência fixa de 100 Hz e potência média de 1,3 W; enquanto que para a dentina, a freqüência foi fixa em 15 Hz enquanto que a potência média variou em 800, 700 e 600 mW. O esmalte demonstrou ser mais capaz de dissipar as ondas de choque do que a dentina, uma vez que as trincas originadas nas microcavidades foram mais freqüentes em tecido dentinário, diferentemente do esmalte. Em conclusão, parece que para manter os aspectos de definição de bordas é importante escolher tempos de irradiação mais curtos, quando as potências médias forem mantidas mais altas, ou seja, energia total entregue mais baixa e bem localizada. Resumo em inglês The efficiency of the ablation obtained with a picosecond-pulsed laser system minimizes material collateral damage because of the etching and plasma formation mechanism. It prevents the excessive generation of shock waves and promotes a considerable decrease of mechanical side effects. In this study, a Nd:YAG picosecond-pulsed Q-switched and mode-locked laser (Antares 76-s, Coherent, Palo Alto, CA) was used. Fifteen microcavities were prepared in the enamel, and nine micr (mais) ocavities were prepared in the dentin of three recently extracted human molars. The parameters for irradiating enamel followed a fixed frequency of 100 Hz and an average power level of 1.3 W; for dentin, the frequency was fixed in 15 Hz, and the average power level varied between 800, 700 and 600 mW. Enamel proved more capable to dissipate shock waves than dentin, since cracks originating from microcavities were more frequent in dentin. In conclusion, it seems that in order to keep defined edges, it is important to choose shorter irradiation periods when average power levels are kept high, which results in lower and best-localized total energy delivery.

Scientific Electronic Library Online (Portuguese)

5

Irradiação de polímeros com feixe de elétrons: caracterização de íons positivos através da técnica de tempo-de-vôo/ Irradiation of polymers using electron beams: characterization of positive ions through the time-of-flight technique

Rocco, Maria Luiza Miranda; Pontes, Frederico Celestino; Faraudo, Gustavo Sebastian; Souza, Gerardo Gerson Bezerra de; Weibel, Daniel Eduardo; Pinho, Roberto Rosas
2004-02-01

Resumo em inglês With the aim of studying the interaction of fast electrons with solid surfaces we have developed an experimental set-up based on electron stimulated desorption (ESD) coupled to time-of-flight (TOF) mass spectrometry. Poly(methyl methacrylate) and poly(vynil chloride) samples have been irradiated by a pulsed electron beam of 1.2 keV and 0.18 µs FWHM. The results show that H+ is the main ionic species to desorb after electron bombardment. In addition, other ionic fragments (mais) were also observed and assigned. These results show the potentiality of this technique in the study of ESD of polymers.

Scientific Electronic Library Online (Portuguese)