Sample records for magnetic materials
from WorldWideScience.org

Sample records 1 - 20 shown. Select sample records:



1

Compostos magnéticos moleculares: o desenvolvimento de novos materiais magnéticos nanoestruturados/ Molecular magnetic compounds: the development of new nanostrutured magnetic materials

Guedes, Guilherme P.; Allão, Rafael A.; Mercante, Luiza A.; Vaz, Maria G. F.; Novak, Miguel A.
2010-01-01

Resumo em inglês The development of new magnetic materials has attracted attention of researchers of different areas. In the last decades, a distinguished class of materials emerged in magnetism, in which the magnetic moment is delocalized over molecules. By varying the synthetic conditions it is possible to obtain a large variety of structures and properties using the same starting molecules. These materials have a great scientific appeal due to the possibility of presenting not only mag (mais) netic, but also optical or electrical transport properties. In this review we will present an overview of some molecular magnetic compounds, in particular molecular nanomagnets.

Scientific Electronic Library Online (Portuguese)

2

Experiência de Oersted em sala de aula/ Oersted's experience in the classroom

Chaib, J.P.M.C.; Assis, A.K.T.
2007-01-01

Resumo em português Em 1820 Oersted observou a deflexão de um pequeno ímã colocado próximo a um fio com corrente constante. Esta descoberta fundamental desencadeou uma série de pesquisas que levou à unificação dos fenômenos elétricos e magnéticos. Este artigo visa contribuir para o resgate da relevância da experiência de Oersted. É feita uma breve contextualização histórica desta experiência. Descreve-se uma reprodução moderna dos procedimentos e observações de Oersted com materiais de baixo custo. Resumo em inglês In 1820 Oersted observed the deflection of a small magnet placed close to a wire carrying a steady current. This fundamental discovery unleashed a series of researches which led to the unification of the electric and magnetic phenomena. The goal of this paper is to contribute to show the importance of Oersted's experiment. It is made a short historical contextualization of this experiment. It is described a modern reproduction of the procedures and observations of Oersted utilizing low cost materials.

Scientific Electronic Library Online (Portuguese)

3

Prego voador: um desafio para estudantes de eletromagnetismo/ Flying nail: a challenge to eletromagnetism students

Krapas, Sonia; Rodrigues, Luiz Cláudio; Miranda Neto, Álvaro Vieira de; Cavalcanti, Gildo de Holanda
2005-12-01

Resumo em português Neste trabalho apresentamos um experimento didático de baixo custo, produzido por um aluno de uma disciplina do curso de licenciatura em Física da Universidade Federal Fluminense, que tem sua ênfase no estudo dos movimentos - inesperados - de materiais ferromagnéticos sob a ação de campos magnéticos produzidos por um solenóide. O experimento, incluindo material utilizado, montagem e procedimentos, é mostrado em detalhe. São apresentadas, na forma de uma discuss� (mais) �o, as várias tentativas de explicação para os movimentos obtidos. Objetiva-se a capacitação de professores em sustentar uma discussão com seus alunos. Resumo em inglês In this work we present a low cost didactic experiment - designed by a student in a course for undergraduate students of Physics at Universidade Federal Fluminense. The emphasis of the experiment is on the study of the unexpected motion of ferromagnetic materials under the action of magnetic fields produced by a solenoid. The experiment is described in details, including the material, the steps and procedures. The attempts for explanation for such movements are presented (mais) in the discussion. This paper aims to provide teachers with some ideas of how to sustain a discussion with their students.

Scientific Electronic Library Online (Portuguese)

4

Condromalácia de patela: comparação entre os achados em aparelhos de RM de alto e baixo campo magnético/ Chondromalacia patellae: comparison of high-field strength versus low-field strength magnetic resonance imaging findings

Freire, Maxime Figueiredo de Oliveira; Fernandes, Artur da Rocha Corrêa; Juliano, Yara; Novo, Neil Ferreira; Carneiro Filho, Mario; Freire Filho, Edison de Oliveira; Carvalho, Alex Franco de; Silva, Débora da Costa
2006-06-01

Resumo em português OBJETIVO: Comparar os aparelhos de ressonância magnética de baixo campo e de alto campo para estudo da cartilagem articular da patela. MATERIAIS E MÉTODOS: Foi realizado estudo usando as seqüências GRE 2D, GRE 3D, FSE T2 e STIR (baixo campo) e TSE T2 SPIR. Cada seqüência foi analisada separadamente para o estudo da cartilagem, sem o conhecimento dos dados do paciente e do resultado das outras seqüências, sendo atribuído grau de lesão de 0 a 3 e descrita a sua l (mais) ocalização. Os resultados de concordância e discordância foram analisados pelos testes de Kappa e McNemar. RESULTADOS: Na faceta medial houve baixas concordâncias e as discordâncias mostraram significativa superestimação. Na faceta lateral houve boas concordâncias e as discordâncias não foram significativas. No ápice houve boas concordâncias e as discordâncias mostraram significativa subestimação. CONCLUSÃO: A seqüência STIR teve a melhor concordância com a seqüência TSE T2 SPIR. Lesões de alto grau são mais bem caracterizadas pelas seqüências do aparelho de baixo campo. Áreas de aumento de sinal dificultam o estudo da cartilagem da faceta medial da patela no aparelho de baixo campo. Resumo em inglês OBJECTIVE: To compare the performance of low-field-strength and high-field-strength magnetic resonance imaging equipments for evaluation of the patella articular cartilage. MATERIALS AND METHODS: The study was developed using GRE 2D, GRE 3D, FSE T2, STIR sequences (low-field) and TSE T2 SPIR sequence. Each sequence has been separately analyzed for evaluation of the cartilage without knowledge of other sequences results or any patients data; the lesion was assigned a grade (mais) from 0 to 3 and had its location defined. Agreement and disagreement results were analyzed by Kappa and McNemar tests. RESULTS: Medial facet has presented low agreement index and disagreements showed to be significantly overestimated. Lateral facet has presented a reasonable agreement index and disagreement index was not significant. Medial ridge has presented a reasonable agreement index and disagreement index has showed to be underestimated. CONCLUSION: The STIR sequence versus TSE T2 SPIR sequence has presented the higher agreement index. High grade lesions are better characterized by low-field-strength magnetic resonance imaging equipment sequences. Areas of increased signal intensity make difficult the study of the patella medial facet cartilage in low-field-strength equipment.

Scientific Electronic Library Online (Portuguese)

5

Óxidos de ferro das frações areia e silte de um Nitossolo desenvolvido de basalto/ Iron oxides of sand and silt fractions in a Nitossolo developed from basalt

Ferreira, B. A.; Fabris, J. D.; Santana, D. P.; Curi, N.
2003-06-01

Resumo em português Foi estudada a composição mineralógica dos óxidos de ferro das frações areia, silte e argila de cinco amostras coletadas de um perfil de um Nitossolo Vermelho desenvolvido de basalto toleítico, localizado próximo a Tupaciguara (18 º 35 ' 33 '' S; 48 º 42 ' 18 '' O), na região do Triângulo Mineiro, Minas Gerais. Porções de areia e de silte foram submetidas à separação magnética e a ataques químicos seletivos com NaOH 5 mol L-1 e com uma mistura ditionito (mais) -citrato-bicarbonato, com o objetivo de identificar os principais óxidos de ferro magnéticos e suas associações mineralógicas. Maghemita (fórmula ideal, gFe2O3) foi o único mineral magnético identificado nas frações areia e silte; não foi encontrada evidência de ocorrência de magnetita nessas frações. Os resultados Mössbauer apenas sugerem a co-existência de mais de um tipo cristaloquímico de maghemita, na fração areia, embora não sejam claramente separáveis dos espectros Mössbauer obtidos sem campo magnético aplicado. A fase magnética mais rica em Al tem fórmula média, deduzida de resultados de microssondagem eletrônica, Fe2,36(2)3+ Al0,24(2)3+ Ti0,06(3)4+ Ä0,341(1) O4 (Ä = vacância catiônica). A ilmenita férrica detectada de dados Mössbauer na porção magnética da fração silte corresponde a uma solução sólida xFe2+Ti4+O3(1-x)Fe2(3+)O3, com x » 0,83. São discutidas algumas dificuldades e alternativas de interpretação dos resultados Mössbauer, como os do presente caso, em que ocorrem contribuições espectrais simultâneas de hematita e maghemita. Resumo em inglês The iron oxide mineralogy of sand, silt and clay fractions was studied in five soil materials. Samples were collected from a pedon of a Red Nitossolo (Brazilian Soil Classification; related to an Alfisol in US Soil Taxonomy) developing on a tholeiitic basalt, near the town Tupaciguara (18 º 35 ' 33 '' S; 48 º 42 ' 18 '' W) in the region of Triângulo Mineiro, state of Minas Gerais, Brazil. Portions of sand and silt were analyzed by magnetic separation and selective chem (mais) ical treatments with NaOH 5 mol L-1, and with a dithionite-citrate-bicarbonate mixture to identify the main iron oxides and their mineralogical associations. Powder X-ray diffraction and Mössbauer spectroscopy analyses of these granulometric fractions revealed that maghemite (ideal formula, gFe2O3) was the only detectable magnetic mineral; no evidence for the existence of magnetite was found in the coarse fractions of this soil. Based on the Mössbauer data, the possibility of co-existence of more than one crystallochemical maghemite type in the sand fraction may be presumed, but no further analysis with applied magnetic field was performed to confirm this hypothesis. From the electronic microprobe, the magnetic phase with highest Al content presented a chemical composition that corresponds to the averaged formula Fe2,36(2)3+ Al0,24(2)3+ Ti0,06(3)4+ Ä0,341(1) O4 (Ä = cation vacancy). The ferric ilmenite found by the Mössbauer data in the magnetic part of the silt fraction is a solid solution (xFe2+Ti4+O3(1-x)Fe2(3+)O3; x » 0,83). Some difficulties of interpretation and alternatives to results of the Mössbauer analysis are discussed for cases, as the present, where soil samples contain mineral mixtures of hematite and maghemite.

Scientific Electronic Library Online (Portuguese)

6

Valores preditivos das categorias 3, 4 e 5 do sistema BI-RADS em lesões mamárias nodulares não-palpáveis avaliadas por mamografia, ultra-sonografia e ressonância magnética/ Predictive values of bi-rads categories 3, 4 and 5 in non-palpable breast masses evaluated by mammography, ultrasound and magnetic resonance imaging

Roveda Junior, Decio; Piato, Sebastião; Oliveira, Vilmar Marques de; Rinaldi, José Francisco; Ferreira, Carlos Alberto Pecci; Fleury, Eduardo de Castro Faria
2007-04-01

Resumo em português OBJETIVO: Avaliar os valores preditivos positivo e negativo das categorias 3, 4 e 5 do sistema BI-RADS™ em lesões mamárias nodulares não-palpáveis avaliadas por mamografia, ultra-sonografia e ressonância magnética. MATERIAIS E MÉTODOS: Vinte e nove pacientes com achados mamográficos de lesões mamárias nodulares não-palpáveis, das classes 3, 4 e 5 do BI-RADS, que realizaram exames complementares de ultra-sonografia e ressonância magnética, além de bió (mais) psia excisional. Realizaram-se 30 biópsias e correlacionaram-se as lesões e suas respectivas classificações de 3 a 5 do BI-RADS com os resultados histopatológicos. O cálculo dos valores preditivos foi feito utilizando-se equações matemáticas específicas. RESULTADOS: O valor preditivo negativo da categoria 3 pela análise mamográfica foi de 69,23%, pela análise ultra-sonográfica foi de 70,58% e pela análise por ressonância magnética foi de 100%. O valor preditivo positivo da categoria 4 pela análise mamográfica foi de 63,63%, pela análise ultra-sonográfica foi de 50% e pela análise por ressonância magnética foi de 30,76%. O valor preditivo positivo da categoria 5 foi de 100% pelas análises mamográfica e ultra-sonográfica e de 92,85% pela análise por ressonância magnética. CONCLUSÃO: O valor preditivo negativo da categoria 3 foi elevado na análise pela ressonância magnética e os valores preditivos positivos foram moderados na categoria 4 e elevados na categoria 5 pelos três métodos. Resumo em inglês OBJECTIVE: To evaluate the predictive value of BI-RADS™ categories 3, 4 and 5 in non-palpable breast masses assessed by mammography, ultrasound and magnetic resonance imaging MATERIALS AND METHODS: Twenty-nine patients with BI-RADS categories 3, 4 and 5 nonpalpable breast masses identified by mammograms were submitted to complementary ultrasound and magnetic resonance imaging studies, besides excisional biopsy. In total, 30 biopsies were performed. The lesions as we (mais) ll as their respective BI-RADS classification into 3, 4 and 5 were correlated with the histopathological results. The predictive values calculation was made by means of specific mathematical equations. RESULTS: Negative predictive values for category 3 were: mammography, 69.23%; ultrasound, 70.58%; and magnetic resonance imaging, 100%. Positive predictive values for category 4 were: mammography, 63.63%; ultrasound, 50%; and magnetic resonance imaging, 30.76%. For category 5, positive predictive values were: mammography and ultrasound, 100%; and magnetic resonance imaging, 92.85%. CONCLUSION: For category 3, the negative predictive value of magnetic resonance imaging was high, and for categories 4 and 5, the positive predictive values of the three modalities were moderate.

Scientific Electronic Library Online (Portuguese)

7

Valor da ressonância magnética no planejamento radioterápico dos tumores de colo de útero: resultados preliminares/ Value of magnetic resonance imaging in the radiotherapy planning of tumours of the uterine cervix: preliminary results

Justino, Pitágoras Baskara; Carvalho, Heloisa de Andrade; Baroni, Ronaldo Hueb; Blasbalg, Roberto; Leite, Claudia da Costa
2005-12-01

Resumo em português OBJETIVO: Verificar o índice de erros geográficos no planejamento radioterápico convencional de pacientes com carcinoma de colo uterino por meio da ressonância magnética. MATERIAIS E MÉTODOS: Trinta e duas pacientes com diagnóstico histológico de carcinoma espinocelular de colo uterino, com indicação de radioterapia, foram analisadas. Foi realizada ressonância magnética da pelve, sendo essas imagens comparadas aos campos clássicos de radioterapia, técnica de (mais) quatro campos em "tijolo". Considerou-se erro geográfico quando o volume alvo não foi englobado pelos campos, com margens mínimas de 1 cm. RESULTADOS: Em 24 pacientes (75%) foi detectada possibilidade de erro geográfico se fossem utilizados os campos convencionais. Em todos os casos o erro foi à custa dos limites anterior (46%) ou posterior (40%) dos campos laterais. CONCLUSÃO: A ressonância magnética evidenciou chance elevada de erro geográfico no planejamento radioterápico convencional na população analisada, tanto nas pacientes com doença em estádios iniciais quanto avançados. Resumo em inglês OBJECTIVE: To assess the rate of geographic miss on conventional radiotherapy planning of patients with cervical cancer, using magnetic resonance imaging. MATERIALS AND METHODS: Thirty-two patients with squamous cell carcinoma of the uterine cervix were studied. Magnetic resonance imaging of the pelvis was performed after clinical staging. Magnetic resonance imaging findings were compared with the classic fields described for the "box" technique. Target volume within less (mais) than 1 cm margins of the fields' limits was considered as geographic miss. RESULTS: Classical radiation field limits were inadequate in 24 cases (75%), all in the anterior (46%) or posterior (40%) border of the lateral fields. CONCLUSION: Magnetic resonance detected a high probability of geographic miss on conventional radiotherapy planning in this population, both in initial and advanced stages of the disease.

Scientific Electronic Library Online (Portuguese)

8

Uso do tensor de difusão na avaliação dos padrões de acometimento da substância branca em pacientes com tumores cerebrais: é uma ferramenta útil para o diagnóstico diferencial?/ Use of diffusion tensor magnetic resonance imaging in the assessment of patterns of white matter involvement in patients with brain tumors: is it useful in the differential diagnosis?

Itagiba, Vanessa Granado Alves; Borges, Rafael; Cruz Jr, Luiz Celso Hygino da; Furtado, Andre Dietz; Domingues, Romeu Côrtes; Gasparetto, Emerson Leandro
2010-12-01

Resumo em português OBJETIVO: Propõe-se avaliar o papel do tensor de difusão na avaliação dos diferentes padrões de acometimento da substância branca em pacientes com tumores cerebrais e a utilidade desta técnica no diagnóstico diferencial dessas neoplasias. MATERIAIS E MÉTODOS: Quarenta e quatro pacientes com tumores cerebrais, incluindo gliomas de baixo grau, astrocitomas anaplásicos, glioblastomas multiformes e metástases, foram estudados com imagens de ressonância magnética (mais) convencional e tensor de difusão. Os tratos de substância branca próximos aos tumores foram caracterizados como deslocados, interrompidos, infiltrados e edematosos. RESULTADOS: Houve significativa sobreposição entre os padrões de acometimento da substância branca pelo tensor de difusão, uma vez que o padrão deslocado foi observado em todos os tipos de tumor. Os padrões interrompido e infiltrado foram encontrados em glioblastomas multiformes e astrocitomas anaplásicos e o padrão edematoso foi observado em metástases. CONCLUSÃO: Os padrões de envolvimento dos tratos de substância branca cerebral avaliados pelo tensor de difusão auxiliam no mapeamento dos tratos adjacentes aos tumores e fornecem informações importantes sobre a extensão do tumor, no entanto, eles não possibilitam fazer a distinção entre gliomas de baixo e alto graus e metástases Resumo em inglês OBJECTIVE: The present study was aimed at evaluating the role of diffusion tensor imaging for the assessment of different patterns of white matter involvement in patients with brain tumors and the utility of this technique for differential diagnosis of such neoplasms. MATERIALS AND METHODS: Forty-four patients with brain tumors, including low-grade gliomas, anaplastic astrocytomas, glioblastomas multiforme and metastases, were studied with conventional and diffusion tenso (mais) r magnetic resonance imaging. White matter tracts around the tumors were characterized as displaced, disrupted, infiltrated and edematous. RESULTS: A significant overlap was observed between patterns of white matter involvement on diffusion tensor images as the displaced pattern was seen in all the types of tumor. Disrupted and infiltrated patterns were found in glioblastomas multiforme and anaplastic astrocytomas. The edematous pattern was found in the cases of metastases. CONCLUSION: Diffusion tensor imaging patterns of white matter involvement assists in the mapping of tracts adjacent to tumors, providing significant data about tumors extent; however, they cannot distinguish low-grade and high-grade gliomas from metastases

Scientific Electronic Library Online (Portuguese)

9

Tumores malignos da cavidade nasal: tomografia computadorizada e ressonância magnética/ Malignant tumors of the nasal cavity: computed tomography and magnetic resonance imaging

Souza, Ricardo Pires de; Paes Junior, Ademar José de Oliveira; Lenh, Carlos Neutzling; Gonzalez, Fábio Mota; Cordeiro, Flamarion de Barros; Yamashiro, Ilka; Rapoport, Abrão
2004-10-01

Resumo em português OBJETIVO: Este estudo propõe-se a avaliar o papel da tomografia computadorizada e da ressonância magnética na caracterização da extensão profunda dos tumores malignos da cavidade nasal. MATERIAIS E MÉTODOS: Entre 1990 e 2000 foram avaliados, retrospectivamente, 12 pacientes com diagnóstico de tumores malignos da cavidade nasal atendidos nos Departamentos de Diagnóstico por Imagem e Cirurgia de Cabeça e Pescoço do Complexo Hospitalar Heliópolis, São Paulo, SP. (mais) Todos os casos foram confirmados com exame anatomopatológico. RESULTADOS: Foi identificada extensão para os seios maxilares e etmoidal em seis pacientes, para a cavidade nasal contralateral, órbita e lâmina crivosa em cinco pacientes, para a nasofaringe e espaço mastigatório em dois pacientes, e para o seio cavernoso, fossas cranianas anterior e média, fossa pterigomaxilar, fissuras orbitárias superior e inferior, seio frontal, seio etmoidal contralateral, lâmina crivosa contralateral, palato duro e fossa pterigopalatina em um paciente. CONCLUSÃO: A análise precisa da extensão local e disseminação tumoral dada pela tomografia computadorizada e ressonância magnética desempenha papel importante no planejamento terapêutico, influenciando também o prognóstico. Resumo em inglês OBJECTIVE: The aim of this study is to evaluate the role of computed tomography and magnetic resonance imaging in the characterization of deep tissue extension of malignant tumors of the nasal cavity. MATERIALS AND METHODS: Twelve patients diagnosed with malignant tumors of the nasal cavity were retrospectively evaluated at the Departments of Diagnostic Imaging and Head and Neck Surgery of the "Complexo Hospitalar Heliópolis", São Paulo, Brazil, between 1990 and 2000. A (mais) ll cases were confirmed by histopathologic examination. RESULTS: Extension to the maxillary and ethmoid sinuses was identified in six patients, extension to contralateral nasal cavity, orbit and lamina cribosa in five patients, extension to nasal pharynx and masticator space in two patients, extension to cavernous sinus, anterior/middle cranial fossa, pterygomaxillary fossa, inferior/superior orbital fissure, frontal sinus, contralateral ethmoid sinus, contralateral lamina cribosa, hard palate and pterygopalatine fossa in one patient. CONCLUSION: It is important to precisely assess the local extension and spread of tumor by computed tomography and magnetic resonance imaging in order to plan the approach to treatment, which will influence the prognosis.

Scientific Electronic Library Online (Portuguese)

10

Tumores glômicos subungueais: achados de imagem/ Subungual glomus tumors: imaging findings

Montandon, Cristiano; Costa, Juliana da Cunha; Dias, Lorena Andrade; Costa, Fernando Henrique Abrão Alves da; Costa, Ana Carolina Mendes da; Daher, Renato Tavares; Montandon Jr, Marcelo Eustáquio
2009-12-01

Resumo em português OBJETIVO: Analisar os principais aspectos de imagem dos tumores glômicos subungueais. MATERIAIS E MÉTODOS: Realizado estudo retrospectivo de oito casos de tumores glômicos subungueais, pertencentes a arquivos de duas clínicas particulares de Goiânia, GO, Brasil. Foram obtidas radiografias em cinco casos, ultrassonografia com Doppler em seis casos e ressonância magnética em cinco casos. RESULTADOS: A idade média de acometimento no presente estudo foi de 39 anos, co (mais) m predomínio do sexo feminino, na proporção de 7:1. Os tumores não apresentaram predileção por nenhum dedo e a maioria localizava-se na região subungueal mediana. A radiografia foi positiva em três casos, demonstrando erosões de pressão. A ultrassonografia com Doppler foi positiva em cinco casos, evidenciando nódulo sólido, hipoecoico e hipervascularizado. A ressonância magnética, em todos os casos, demonstrou nódulo sólido com hipossinal em T1, hipersinal em T2 e captação homogênea do meio de contraste. Em todos os pacientes foi realizada excisão cirúrgica com confirmação anatomopatológica. CONCLUSÃO: A maioria dos tumores glômicos tem localização subungueal. O diagnóstico é clínico, porém geralmente tardio. Os métodos de imagem auxiliam no diagnóstico precoce, além auxiliar no planejamento terapêutico, cujo tratamento de escolha é a excisão cirúrgica. Resumo em inglês OBJECTIVE: To evaluate main imaging findings of subungual glomus tumors. MATERIALS AND METHODS: Retrospective study of eight cases of subungual glomus tumors from the archives of two private clinics in Goiânia, GO, Brazil. Plain radiographs were obtained in five cases, Doppler ultrasonography in five, and magnetic resonance imaging in five cases. RESULTS: Mean age of the patients included in the present study was 39 years, with female predominance (7:1). Tumors didn't pr (mais) esent prevalence in any specific finger and in most of cases the tumor was located in the medial subungual region. Plain radiography was positive in five cases, demonstrating pressure erosion. Doppler ultrasonography was positive in five cases, demonstrating a hypoechoic and hypervascularized solid nodule. Magnetic resonance imaging was positive in all of the cases, showing a solid nodule, hypointense on T1-, hyperintense on T2-weighted image, with homogeneous contrast uptake. All the patients underwent surgical excision of the lesion with histopathological confirmation. CONCLUSION: In most of cases, glomus tumors are subungual. The diagnosis is clinical and generally is lately achieved. Imaging methods are useful tools for the early diagnosis besides aiding in the surgical planning, considering that the treatment of choice is surgical excision.

Scientific Electronic Library Online (Portuguese)

11

Síntese, caracterização e estudo das propriedades catalíticas e magnéticas de nanopartículas de Ni dispersas em matriz mesoporosa de SiO2/ Synthesis, characterization and study of magnetic and catalytic properties of dispersed Ni nanoparticles on mesoporous SiO2 matrix

Carreño, Neftalí L. V.; Leite, Edson R.; Santos, Luís P. S.; Lisboa-Filho, Paulo N.; Longo, Elson; Araújo, Geórgia C. L.; Barison, Andersson; Ferreira, Antônio G.; Valentini, Antoninho; Probst, Luiz Fernando D.
2002-11-01

Resumo em inglês Nickel nanoparticles supported on amorphous silica ceramic matrix were synthesized by the polymeric precursor method. The nanostructure was characterized by NMR, BET, XRD, SEM, TEM, and flame atomic absorption spectrometry techniques. It was observed a dependence of the crystallite size on the thermal annealing, under a N2 atmosphere. The materials presented a high catalytic activity and selectivity upon the beta-pinene hydrogenation reaction. The magnetic hystereses were also correlated with the morphology of the processed material.

Scientific Electronic Library Online (Portuguese)

12

Síndrome SAPHO: entidade rara ou subdiagnosticada?/ SAPHO syndrome: rare or under-diagnosed?

Guerra, Jozephina Gonçalves; Lima, Francisco Ayres Corrêa; Macedo, Lúcia Maria Gonçalves; Rocha, Arthemízio Antônio Lopes; Fernandes, João Luiz
2005-08-01

Resumo em português OBJETIVO: Descrever os achados clínicos, radiológicos e patológicos da síndrome SAPHO e sugerir que, apesar de ser considerada rara, esta síndrome deve estar sendo subdiagnosticada por clínicos e radiologistas, provavelmente em função do desconhecimento das suas características. MATERIAIS E MÉTODOS: Foi realizado estudo retrospectivo de seis casos confirmados desta síndrome, dando-se ênfase aos achados clínicos (idade, sexo e sintomas) e de imagem (cintilogra (mais) fia óssea, radiografia convencional, tomografia computadorizada e ressonância magnética). RESULTADOS: A manifestação clínica inicial de todos os pacientes foi dor na parede torácica ântero-superior há pelo menos quatro meses. Todos apresentavam achados de imagem de processo inflamatório e/ou osteíte e hiperostose nas articulações da parede torácica ântero-superior. As alterações cutâneas da síndrome, tipo pustulose palmoplantar, estiveram presentes em cinco dos seis pacientes. Em nenhum dos seis casos o diagnóstico foi sugerido na consulta clínica inicial ou na primeira interpretação das imagens feita por radiologistas não especialistas em sistema músculo-esquelético. CONCLUSÃO: Os nossos achados estão de acordo com os descritos na literatura, devendo ser considerado este diagnóstico em todo paciente que apresente quadro doloroso de parede torácica acompanhado de manifestações dermatológicas e/ou osteíte. Resumo em inglês OBJECTIVE: To describe the clinical, imaging and pathological findings of SAPHO syndrome and to point out that although considered rare this syndrome may be under-diagnosed by clinicians and radiologists, probably due to unfamiliarity with its features. MATERIALS AND METHODS: A retrospective study of six cases diagnosed in the last six years, with emphasis on clinical findings (age, sex and symptoms) and imaging findings (bone scintigraphy, conventional x-ray, computed to (mais) mography and magnetic resonance imaging) was conducted. RESULTS: The initial clinical presentation in all patients was pain in the upper anterior chest wall for at least four months. Imaging findings of all these patients indicated inflammatory process and/or hyperostosis and osteitis in the joints of the upper anterior chest wall. Skin manifestations of the syndrome, such as palmoplantar pustulosis, were identified in five of the patients. In none of the cases the diagnosis was suggested either at the initial clinical medical appointment or after imaging assessment by radiologists not specialized in musculoskeletal system. CONCLUSION: Our clinical and imaging findings are in line with the ones described in the literature. This diagnosis must be considered for each patient presenting with pain in the upper anterior chest wall associated with skin lesions and/or osteitis.

Scientific Electronic Library Online (Portuguese)

13

Sinais de hipervascularização em imagens de ressonância magnética em metástases ósseas de carcinoma de células renais/ Signs of hypervascularization at magnetic resonance imaging in bone metastases from renal cell carcinoma

Feltrin, Leonir Terezinha; Ferreira, José Renato; Mamere, Augusto Elias; Coelho, Rafael Darahem de Souza; Cecin, Alexandre Oliveira; Lucchesi, Fabiano Rubião; Pinheiro, Marco Antônio Lopes; Trad, Clóvis Simão
2009-06-01

Resumo em português OBJETIVO: Avaliar a frequência de hipervascularização pela visualização de vasos no interior ou ao redor de metástases ósseas de carcinoma de células renais. MATERIAIS E MÉTODOS: Foram avaliados, retrospectivamente, exames de ressonância magnética de 13 pacientes com diagnóstico de carcinoma de células renais, com 15 lesões ósseas metastáticas, que não haviam sido submetidos a nenhum tratamento. RESULTADOS: Foram encontrados sinais de hipervascularizaçã (mais) o em 12 das 15 lesões (80%), sendo 6 na coluna lombar, 3 na bacia, 1 na coluna torácica, 1 na ulna e 1 na tíbia. CONCLUSÃO: A alta frequência de hipervascularização em metástases ósseas de carcinoma de células renais encontrada neste trabalho pode sugerir a etiologia renal, tornando-se muito útil na apresentação clínica usual de lesão óssea única com neoplasia primária desconhecida. Resumo em inglês OBJECTIVE: To evaluate the frequency of hypervascularization by visualizing vascular structures inside or around bone metastases from renal cell carcinoma. MATERIALS AND METHODS: Magnetic resonance imaging studies of 13 untreated patients with diagnosis of renal cell carcinoma and 15 metastatic bone lesions were retrospectively evaluated. RESULTS: Signs of hypervascularization were found in 12 of the 15 bone lesions (80%), 6 of them localized in the lumbar spine, 3 in the (mais) hip, 3 in the thoracic spine, 1 in the ulna and 1 in the tibia. CONCLUSION: The high frequency of hypervascularization of bone metastases from renal cell carcinoma found in the present study may suggest that the renal etiology is a useful parameter in the evaluation of a usual clinical presentation of a single bone lesion with unknown primary neoplasm.

Scientific Electronic Library Online (Portuguese)

14

Ressonância magnética para avaliação dos limites dos campos clássicos de radioterapia em pacientes portadoras de neoplasia maligna de colo uterino/ Magnetic resonance imaging in the evaluation of standard radiotherapy field borders in patients with uterine cervix cancer

Freire, Geison Moreira; Dias, Rodrigo Souza; Giordani, Adelmo José; Ribalta, Julisa Chamorro Lascasas; Segreto, Helena Regina Comodo; Segreto, Roberto Araujo
2010-06-01

Resumo em português OBJETIVO: Avaliar os limites de campo padronizados para radioterapia de neoplasia maligna de colo uterino com o uso de ressonância magnética e verificar a importância deste exame na redução de possíveis erros de planejamento com técnica convencional. MATERIAIS E MÉTODOS: Foram analisados, retrospectivamente, exames de ressonância magnética do planejamento de 51 pacientes tratadas devido a neoplasia de colo uterino. Os parâmetros estudados foram limites anterior (mais) e posterior no corte sagital. RESULTADOS: Observou-se, no corte sagital das ressonâncias magnéticas, que o limite de campo anterior apresentou-se inadequado em 20 (39,2%) pacientes e que houve perda geográfica em 37,3% dos casos no limite posterior. A inadequação de ambos os limites de campo não se relacionou com parâmetros clínicos como idade das pacientes, estadiamento, tipo e grau histológico. CONCLUSÃO: A avaliação dos limites de campo padronizados pela literatura com o uso de ressonância magnética mostrou altos índices de inadequação dos limites do campo lateral, assim como a importância do uso deste exame no planejamento radioterápico de pacientes portadoras de câncer de colo uterino com a finalidade de reduzir a perda geográfica no volume alvo de tratamento. Resumo em inglês OBJECTIVE: To evaluate, by means of magnetic resonance imaging, the standardized field borders in radiotherapy for malignant neoplasm of uterine cervix, and to determine the role of this method in the reduction of possible planning errors related to the conventional technique. MATERIALS AND METHODS: Magnetic resonance imaging studies for planning of treatment of 51 patients with uterine cervix cancer were retrospectively analyzed. The parameters assessed were the anterior (mais) and posterior field borders on sagittal section. RESULTS: The anterior field border was inappropriate in 20 (39.2%) patients and geographic miss was observed in 37.3% of cases in the posterior border. The inappropriateness of both field borders did not correlate with clinical parameters such as patients' age, tumor staging, histological type and degree. CONCLUSION: The evaluation of standardized field borders with the use of magnetic resonance imaging has demonstrated high indices of inappropriateness of the lateral field borders, as well as the relevant role of magnetic resonance imaging in the radiotherapy planning for patients with uterine cervix cancer with a view to reduce the occurrence of geographic miss of the target volume.

Scientific Electronic Library Online (Portuguese)

15

Ressonância magnética das vias lacrimais: estudo comparativo entre bobinas de superfície convencionais e microscópicas/ Magnetic resonance dacryocystography: comparison between conventional surface coils and microscopic coils

Abreu Junior, Luiz de; Wolosker, Angela Maria Borri; Borri, Maria Lucia; Galvão Filho, Mário de Melo; D'Ippolito, Giuseppe; Hartmann, Luiz Guilherme de Carvalho; Castro, Cláudio Campi de
2008-08-01

Resumo em português OBJETIVO: A ressonância magnética tem sido utilizada para avaliar as vias lacrimais, com vantagens em relação à dacriocistografia por raios-X. O objetivo deste trabalho é obter imagens de alta resolução utilizando bobinas de superfície microscópicas para avaliação de estruturas normais das vias lacrimais, comparando com o aspecto observado utilizando-se bobinas de superfície convencionais. MATERIAIS E MÉTODOS: Cinco voluntários assintomáticos, sem históri (mais) co de lacrimejamento, submeteram-se a ressonância magnética de alto campo, com bobinas de superfície (convencional e microscópica), com seqüência STIR após instilação de soro fisiológico. A identificação das estruturas anatômicas normais das vias lacrimais foi comparada utilizando-se as duas bobinas. Mediante uso de um sistema de escore, um valor médio de cada estrutura foi calculado por dois examinadores, consensualmente. RESULTADOS: Em 90% das vezes houve aumento do escore, atribuído à estrutura anatômica no estudo com a bobina microscópica. Em média, houve aumento de 1,17 ponto no escore, por estrutura anatômica visualizada, quando se utilizou a bobina microscópica. Observou-se, ainda, melhora subjetiva da relação sinal-ruído ao se utilizar a bobina microscópica. CONCLUSÃO: A dacriocistografia por ressonância magnética com bobinas microscópicas é um método adequado para o estudo das vias lacrimais, resultando em imagens de melhor qualidade quando comparada ao uso de bobinas de superfície convencionais. Resumo em inglês OBJECTIVE: Magnetic resonance imaging has been utilized in the evaluation of the lacrimal apparatus with some advantages over conventional dacryocystography. The present study was aimed at acquiring high-resolution images utilizing microscopic coils for evaluating typical structures of the lacrimal apparatus as compared with the findings observed with conventional surface coils. MATERIALS AND METHODS: Five asymptomatic volunteers with no history of epiphora were submitted (mais) to high-field magnetic resonance imaging with microscopic and conventional surface coils, and STIR sequence after instillation of saline solution. The definition of normal anatomic structures of lacrimal apparatuses was compared utilizing conventional and microscopic surface coils. Based on a consensual scoring system, the mean values for each structure were calculated by two observers. RESULTS: In 90% of cases, higher scores were attributed to images acquired with the microscopic coil. On average, a 1.17 point increase was observed in the scoring of anatomic structures imaged with the microscopic coil. Additionally, a subjective improvement was observed in the signal-to-noise ratio with the microscopic coil. CONCLUSION: Magnetic resonance dacryocystography with microscopic coils is the appropriate method for evaluating the lacrimal apparatus, providing images with better quality as compared with those acquired with conventional surface coils.

Scientific Electronic Library Online (Portuguese)

16

Ressonância magnética da osteonecrose do joelho: estudo de 19 casos/ Magnetic resonance imaging of knee osteonecrosis: a study of 19 cases

Cunha, Daniel Leme da; Carvalho, Antonio Carlos Pires; Ribeiro, Elísio José Salgado; Domingues, Romeu Côrtes
2010-04-01

Resumo em português OBJETIVO: Descrever os achados epidemiológicos, clínicos e de ressonância magnética da osteonecrose das porções distal do fêmur e proximal da tíbia. MATERIAIS E MÉTODOS: Avaliação de 19 pacientes (12 mulheres e 7 homens), sem história prévia de fatores causais, com achados à ressonância magnética sugestivos de osteonecrose do platô tibial ou côndilo femoral. RESULTADOS: Verificou-se a presença de anormalidades osteocondrais em 63,1% dos casos e em 73,6% (mais) destes houve associação com lesão meniscal ipsilateral. Houve também importante associação com edema na medular óssea em correspondência (grau III em 16 casos). CONCLUSÃO: A ressonância magnética demonstrou ser um método não invasivo com boa sensibilidade no diagnóstico da osteonecrose do joelho, bem como das lesões associadas, sendo mais frequente nas mulheres (63% dos casos). Resumo em inglês OBJECTIVE: To describe epidemiological, clinical and magnetic resonance imaging findings of osteonecrosis in the distal femur and proximal tibia. MATERIALS AND METHODS: Evaluation of 19 patients (12 women and 7 men), with no previous history of causative factors, with magnetic resonance imaging findings suggestive of osteonecrosis in the tibial plateau or femoral condyle. RESULTS: Osteochondral abnormalities were observed in 63.1% of the cases; in 73.6% of them, such abno (mais) rmality was associated with ipsilateral meniscal lesion. Also, a significant association with bone marrow edema (grade III in 16 cases) was observed. CONCLUSION: Magnetic resonance imaging has demonstrated to be a noninvasive method with good sensitivity in the diagnosis of knee osteonecrosis as well as of associated lesions which are most frequently found in women (63% of cases).

Scientific Electronic Library Online (Portuguese)

17

Quantificação do fluxo portal em indivíduos sadios: comparação entre ressonância magnética e ultra-som Doppler/ Measurement of portal blood flow in healthy individuals: a comparison between magnetic resonance imaging and Doppler ultrasound

Costa, Juliana Dantas da; Leão, Alberto Ribeiro de Souza; Santos, José Eduardo Mourão; Moulin, Danilo Sales; Sebastianes, Patrícia Moreno; D'Ippolito, Giuseppe
2008-08-01

Resumo em português OBJETIVO: Avaliar a concordância entre a ultra-sonografia com Doppler e a ressonância magnética na quantificação do fluxo portal em indivíduos sadios, e avaliar a reprodutibilidade destes métodos diagnósticos. MATERIAIS E MÉTODOS: Foi realizado estudo prospectivo, transversal, observacional e autopareado, avaliando 20 voluntários sadios submetidos a mensuração do fluxo portal por meio de ultra-sonografia com Doppler e por ressonância magnética, executada por (mais) dois observadores independentes. Foram calculadas as concordâncias entre os métodos e entre os observadores utilizando-se o coeficiente de correlação intraclasses e o coeficiente de Pearson. RESULTADOS: A concordância entre os exames de ultra-sonografia com Doppler e de ressonância magnética foi baixa (coeficiente intraclasses: 1,9%-18,2%; coeficiente de Pearson: 0,1%-13,7%; p=0,565). Os valores da média de fluxo portal medido pela ultra-sonografia e pela ressonância magnética foram, respectivamente, de 0,768 l/min e 0,742 l/min. A quantificação do fluxo portal medida pela ultra-sonografia e pela ressonância magnética demonstrou, respectivamente, concordância interobservador regular (coeficiente intraclasses: 43,3%; coeficiente de Pearson: 43,0%) e concordância excelente (coeficiente intraclasses: 91,4%; coeficiente de Pearson: 93,4%). CONCLUSÃO: A ressonância magnética é um método confiável para quantificar o fluxo portal, mostrando melhor concordância interobservador do que a ultra-sonografia com Doppler. Os dois métodos apresentam baixa concordância entre si na quantificação do fluxo portal. Resumo em inglês OBJECTIVE: To evaluate the inter-observer agreement between Doppler ultrasonography and magnetic resonance imaging in the quantification of portal blood flow in healthy individuals, as well as evaluating the reproducibility of both methods. MATERIALS AND METHODS: A prospective, transverse, observational and self-paired study was developed evaluating 20 healthy volunteers whose portal blood flow was measured by means of Doppler ultrasonography and magnetic resonance imagin (mais) g performed by two independent observers. Interobserver and intermethod agreements were calculated using the intraclass and Pearson's correlation coefficients. RESULTS: The agreement between Doppler ultrasonography and magnetic resonance imaging was low (intraclass coefficient: 1.9%-18.2%; Pearson's coefficient: 0.1%-13.7%; p=0.565). Mean values for the portal blood flow measured by Doppler ultrasonography and magnetic resonance imaging were respectively 0.768 l/min and 0.742 l/min. Interobserver agreement for quantification of the portal blood flow by Doppler ultrasonography and magnetic resonance imaging was respectively reasonable (intraclass coefficient: 43.3%; Pearson's coefficient: 43.0%) and excellent (intraclass coefficient: 91.4%; Pearson's coefficient: 93.4%). CONCLUSION: In the present study, magnetic resonance imaging demonstrated to be a reliable method for quantifying the portal blood flow, with a higher interobserver agreement than Doppler ultrasonography. The intermethod agreement was low.

Scientific Electronic Library Online (Portuguese)

18

Pré-tratamento físico: um procedimento importante para o aumento na resolução espectral em estudos de microestrutura de polímeros por RMN13C em solução/ Pre-physical treatment: an important procedure to improve spectral resolution in polymers microstructure studies using 13C solution NMR

Pedroza, Oscar J. O.; Tavares, Maria I. B.
2004-01-01

Resumo em português Em um material polimérico as variações nas propriedades físicas podem ser avaliadas pelo conhecimento da sua microestrutura. Os estudos de microestrutura em materiais poliméricos são geralmente realizados por ressonância magnética nuclear (RMN) em solução empregando o núcleo de carbono-13. Neste tipo de estudo a resolução espectral é muito importante e esta depende do preparo da amostra. Foi observado que um pré-tratamento físico permite obter uma melhor r (mais) esolução espectral e, por conseqüência, informações mais detalhadas sobre os encadeamentos nas cadeias poliméricas podem ser obtidos. Isto facilita a determinação das estereoseqüências. Resumo em inglês Changes in physical properties of polymeric materials can be evaluated from their microstructures, which can be investigated using solution carbon-13 nuclear magnetic resonance (NMR). In this type of study spectral resolution is very important, which obviously depend on the sample and solvent. A pre physical treatment allows for an improvement in the spectral resolution. Consequently, more information on chain linking can be obtained, thus facilitating the determination of the stereosequences.

Scientific Electronic Library Online (Portuguese)

19

Protocolo de testes de aceitação em equipamentos de imagem por ressonância magnética/ Acceptance testing protocol for magnetic resonance imaging systems

Mazzola, Alessandro André; Herdade, Silvio Bruni; Koch, Hilton Augusto; Carvalho, Antonio Carlos Pires
2005-06-01

Resumo em português OBJETIVO: Este trabalho tem como objetivo criar um protocolo de testes de aceitação para equipamentos de imagem por ressonância magnética e demonstrar como e quais tipos de dispositivos de teste podem ser usados para a coleta de dados. MATERIAIS E MÉTODOS: Para cada um dos 15 testes selecionados foram elaborados a definição, o procedimento, a forma de análise e o critério de aceitação. RESULTADOS: Através dos testes de aceitação descritos é possível verifi (mais) car características técnicas que constam nas propostas de venda dos fabricantes, assim como estabelecer valores de referências para serem utilizados em posteriores testes de constância. CONCLUSÃO: Futuros programas de garantia da qualidade em imagem por ressonância magnética devem considerar testes semelhantes ou iguais aos descritos neste trabalho. Resumo em inglês OBJECTIVE: To develop an acceptance testing protocol for magnetic resonance imaging systems and to show which and how phantoms could be used to collect data. MATERIALS AND METHODS: The definition, procedure, analysis and the acceptation criteria were created for each of 15 selected tests. RESULTS: These tests allow the evaluation of technical specifications stated on the manufacturer's sales proposal and to establish reference values to be used in subsequent constancy tes (mais) ts. CONCLUSION: Future quality assurance programs in magnetic resonance imaging should consider employing tests similar or equal to the ones described in this paper.

Scientific Electronic Library Online (Portuguese)

20

Prevalência de artefatos em exames de ressonância magnética do abdome utilizando a seqüência GRASE: comparável com as melhores seqüências rápidas?/ Prevalence of artifacts in abdominal magnetic resonance imaging using GRASE sequence: a comparison with TSE sequences

Francisco, Viviane Vieira; D'Ippolito, Giuseppe; Silva, Gláucia Palácio de Andrade e; Bezerra, Alexandre Sérgio de Araújo; Szejnfeld, Jacob
2005-09-01

Resumo em português OBJETIVO: Determinar a freqüência global de artefatos na seqüência "gradient and spin echo" (GRASE), por tipo e grau do artefato, em exames de ressonância magnética de abdome; realizar comparação entre as seqüências GRASE e duas seqüências TSE previamente selecionadas como aquelas com melhor relação sinal-ruído e menor incidência de artefatos. MATERIAIS E MÉTODOS: Foi realizado estudo prospectivo, autopareado, em 86 pacientes submetidos a ressonância mag (mais) nética de abdome superior, sendo adquiridas a seqüência GRASE com sincronizador respiratório e supressão de gordura e seis seqüências TSE ponderadas em T2. Dentre as seis seqüências TSE, foram previamente selecionadas aquelas com melhor relação sinal-ruído e menor número de artefatos, que foram as realizadas com supressão de gordura e com sincronizador respiratório, sendo uma com bobina de corpo (seqüência 1) e outra com bobina de sinergia (seqüência 2). A análise das imagens foi realizada por dois observadores em consenso, quanto a presença, grau e tipo de artefato. Posteriormente os dados foram analisados estatisticamente, através do teste de Friedman e do qui-quadrado. RESULTADOS: A freqüência absoluta de artefatos nas seqüências utilizadas foi de 65,02%. Os artefatos mais encontrados nas três seqüências estudadas foram os de respiração (30%) e de pulsação (33%). Apenas 3% dos casos apresentaram algum tipo de artefato que dificultava a análise das imagens. As freqüências de artefatos nas diversas seqüências foram: GRASE, 67,2%; seqüência TSE 1, 62,2%; seqüência TSE 2, 65,5%. Não houve diferença estatisticamente significante na freqüência de artefatos encontrados nas seqüências GRASE e nas seqüências TSE (p = 0,845; NS). CONCLUSÃO: As seqüências GRASE e TSE ponderadas em T2 com sincronizador respiratório e com supressão de gordura, independentemente da bobina utilizada, apresentam freqüentemente artefatos, porém com incidência semelhante e geralmente sem interferência na avaliação das imagens. Resumo em inglês OBJECTIVE: To determine the overall frequency of artifacts per type and grade using the GRASE sequence in abdominal magnetic resonance; to compare GRASE sequences with two previously selected TSE sequences as well as sequences with best signal-noise ratio and lower incidence of artifacts. MATERIALS AND METHODS: A prospective self-paired study was carried out in 86 patients submitted to upper abdominal magnetic resonance using a GRASE sequence obtained upon respiratory tri (mais) ggered and fat suppression and six TSE T2-weighted sequences. Among the six TSE sequences, those bearing the best signal-noise ratio and lower number of artifacts were previously selected, which consisted of those performed with fat suppression and respiratory triggering: one using a conventional body coil (sequence 1) and a second sequence using a synergy coil (sequence 2). Image analysis was carried out by two observers upon consensus regarding the presence, grade and type of artifact thereon. Subsequently, data were statistically analyzed using the Friedman test and chi-square. RESULTS: The absolute frequency of artifacts in all sequences was 65.02%. Most common artifacts in the three sequences analyzed were breathing (30%) and pulsation (33%) artifacts. Only in 3% of the cases artifacts interfered with the analysis of the images. The frequency of artifacts in the different sequences was: GRASE, 67.2%; TSE sequence 1, 62.2%; TSE sequence 2, 65.5%. There was no significant statistical difference between artifact frequency seen with GRASE and TSE sequences (p = 0.845; NS). CONCLUSION: GRASE and TSE T2-weighted, respiratory triggered, fat suppressed sequences often produce artifacts, notwithstanding the coil, although, with similar frequency and generally without interfering with the evaluation of the images.

Scientific Electronic Library Online (Portuguese)

21

Preparação, caracterização e degradação de blendas PS/TPS usando glicerol e óleo de buriti como plastificantes/ Preparation, characterization and degradation of PS/TPS blends using glycerol and buriti oil as plastiscizers

Schlemmer, Daniela; Sales, Maria J. A.; Resck, Inês S.
2010-01-01

Resumo em português Poliestireno (PS) é um dos materiais descartáveis mais usados no nosso cotidiano, mas ele não se decompõe facilmente. A adição de amido de mandioca ao PS pode melhorar a sua degradabilidade, tendo em vista ser o amido um polímero biodegradável. O objetivo deste trabalho foi desenvolver blendas de PS e (amido termoplástico) TPS usando dois diferentes plastificantes: glicerol e óleo de buriti, sendo esse óleo um plastificante natural e original para o amido. As b (mais) lendas PS/TPS foram preparadas em diversas composições por casting e em seguida caracterizadas por termogravimetria (TG), calorimetria exploratória diferencial (DSC), análise termomecânica (TMA) e ressonância magnética nuclear (RMN) 13C. As blendas PS/TPS com óleo de buriti apresentaram uma contínua redução em suas Tg e Ta. Nas blendas com glicerol esses parâmetros permaneceram praticamente constantes. As blendas também foram submetidas a testes de degradação no solo e depois analisadas por TG e RMN. A análise das blendas PS/TPS com óleo de buriti mostrou que houve um aumento da perda de massa nas curvas TG. Nos espectros de RMN 13C, todos os picos referentes ao amido desapareceram, depois do teste de aterro, sugerindo que houve consumo do amido das blendas por microorganismos. De acordo com as análises realizadas, a adição do TPS produzido com óleo de buriti pode melhorar a degradabilidade do PS. Resumo em inglês Polystyrene (PS) is one of the most used disposable materials in our daily life, but it does not decompose easily. The addition of cassava starch to PS can improve its degradability since starch is a biodegradable polymer. The aim of this work was to develop blends of PS and thermoplastic starch (TPS) using two different plasticizers: buriti glycerol and buriti oil, a novel and natural plasticizer for starch. PS/TPS blends were prepared in various contents with the castin (mais) g technique and analyzed by thermogravimetry (TG), differential scanning calorimetry (DSC), thermomechanical analysis (TMA) and 13C nuclear magnetic resonance (NMR). PS/TPS blends with buriti oil presented a continuous reduction in Tg and Ta. For blends with glycerol these parameters remained practically constant. PS/TPS blends were submitted to degradation by soil burial testing and then analyzed by TG and 13C NMR. The analysis of PS/TPS blends with buriti oil indicated an increase in weight loss in the TG curves. All NMR peaks associated with starch disappeared after the soil burying test, probably due to the consumption of starch by microorganisms. The results showed that addition of TPS produced with buriti oil to PS can probably improve its degradability.

Scientific Electronic Library Online (Portuguese)

22

Preparação de argila modificada com cloreto de cetilpiridíneo e avaliação da interação desta com o PVC/ Preparation of modified clay with cetylpyridinium chloride and evaluation of their interaction with PVC

Resende, Daniel K.; Dornelas, Camila B.; Tavares, Maria I. B.; Gomes, Ailton S.; Moreira, Leonardo. A.; Cabral, Lúcio M.; Simeoni, Luiz. A.
2010-09-01

Resumo em português Foi preparada uma argila modificada com cloreto de cetilpiridíneo a partir da argila sódica por troca de cátions em solução. Foi avaliada a quantidade de agente de modificação em relação à argila sódica e o tempo reacional. Os materiais obtidos foram caracterizados por difração de raio X (XRD), análise termogravimétrica (TGA) e ressonância magnética nuclear (RMN) de baixo campo. Após a caracterização foi confirmada a modificação da argila e, também, (mais) foi verificado que o produto obtido pode ser empregado na preparação de nanocompósitos de PVC, considerando que o início da degradação do material preparado ocorreu em temperatura superior às comumente utilizadas no processamento do polímero. A adição da argila modificada apresentou uma dispersão adequada no PVC e manteve o início da degradação do material em temperatura compatível com o processamento do polímero, gerando um nanocompósito com parte esfoliada e intercalada. Resumo em inglês A modified silicate with cetylpyridinium was prepared from sodium clay with cation exchange in solution. The amount of modification agent for clay and the reaction time were evaluated. The materials produced were characterized using X ray diffraction (XRD), termogravimetric analysis (TGA) and low field nuclear magnetic resonance (NMR). The formation of new organic clay was confirmed, which was introduced in PVC for the formation of nanocomposites. The beginning of degrada (mais) tion of the new clay occurred at temperatures higher than commonly used in the processing of PVC. The nanocomposites were partially exfoliated and partially intercalated.

Scientific Electronic Library Online (Portuguese)

23

Polímeros condutores intrínsecos e seu potencial em blindagem de radiações eletromagnéticas/ Intrinsically conducting polymers and their potencial in electromagnetic interference shielding

Faez, Roselena; Rezende, Mirabel C.; Martin, Inácio M.; De Paoli, Marco-A.
2000-09-01

Resumo em português A procura por novos materiais que possuam propriedades magnéticas e dielétricas adequadas ao uso em absorvedores de radiação eletromagnética é de grande importância. Dentre os materiais em estudo, os polímeros condutores têm sido aplicados como centros de absorção de radiação, devido à possibilidade de variação da sua condutividade com a freqüência da radiação das ondas incidentes, sendo esta pesquisa o estado da arte no processamento de materiais abso (mais) rvedores de radiação (MAR). O objetivo deste trabalho é apresentar a ampla faixa de propriedades dos polímeros condutores, correlacionando-as com o potencial de aplicação destes materiais como aditivos no processamento de MAR. Uma breve análise dos resultados obtidos com uma blenda de EPDM contendo 30-80 %(m/m) de PAni-DBSA e espessuras de 1 e 3 mm, analisadas na faixa de 8-12 GHz, mostra que o material absorveu na faixa de 50 a 90% da radiação incidente. Resumo em inglês The search for new materials possessing magnetic and dieletric properties adequated to be used as radar absorbing materials has been of great importance. Among the materials under study, conducting polymers have been applied due to the possibility of variation of their conductivity with the frequency of the incident radiation. These research areas have been considered the state of the art in the processing of radar absorbing materials. The aim of this work is to present t (mais) he large range of properties of the conducting polymers and their correlation with the potential application of these materials as electromagnetic radiation absorbers. Some results are also presented on blends of EPDM and 30-80% (w/w) of PAni-DBSA with thickness of 1 and 3 mm, analysed in the range of 8-12 GHz, which absorbed in the range of 50-90% of incident radiation.

Scientific Electronic Library Online (Portuguese)

24

Perda auditiva neurossensorial súbita idiopática: evolução na presença de hipertensão arterial sistêmica, diabetes melito e dislipidemias/ Idiopathic sudden sensorineural hearing loss: evolution in the presence of hypertension, diabetes mellitus and dyslipidemias

Nagaoka, Jayson; Anjos, Marcelo Ferreira dos; Takata, Thales Takeo; Chaim, Renan Moukbel; Barros, Flavia; Penido, Norma de Oliveira
2010-06-01

Resumo em português Estudo retrospectivo com o objetivo de avaliar a interferência das doenças associadas na evolução e prognóstico da perda auditiva neurossensorial súbita idiopática. MATERIAL E MÉTODO: Estudo caso controle. Trinta e cinco pacientes com perda auditiva neurossensorial súbita idiopática divididos em dois grupos, um com doenças associadas (hipertensão arterial sistêmica, diabetes melito e dislipidemias) e outro sem doenças associadas. Avaliação das variáveis: (mais) idade, sexo, doença associada, presença de zumbido, tontura e plenitude aural, presença de microangiopatia cerebral na ressonância magnética, alteração no fundo de olho, tempo de início de tratamento, taxa de melhora auditiva, evolução do índice do reconhecimento da fala. Dados avaliados estatisticamente. RESULTADOS: O grupo com doença associada, quando comparado ao grupo sem doença associada, apresenta idade mais elevada, maior número de pacientes com microangiopatia cerebral na ressonância magnética e recuperação mais lenta do índice de reconhecimento da fala. CONCLUSÃO: Perda auditiva neurossensorial súbita idiopática na presença da hipertensão arterial sistêmica, diabetes melito e dislipidemias, em indivíduos mais velhos, está associada a uma maior prevalência de achados de microangiopatias cerebrais nos exames de ressonância magnética, e à recuperação auditiva mais lenta na melhora do índice de reconhecimento da fala. Resumo em inglês Retrospective study aiming at evaluating the interference of associate diseases in the evolution and prognosis of idiopathic sudden sensorineural hearing loss. MATERIALS AND METHODS: Case-Control Study. Thirty-five patients with idiopathic sudden sensorineural hearing loss were divided in two groups, one of them with associate diseases (hypertension, diabetes mellitus and dyslipidemias), and another one without co-occurrence of such diseases. The groups were evaluated reg (mais) arding: age, gender, associate diseases, presence of tinnitus, dizziness and ear fullness sensation, presence of cerebral microangiopathy observed in magnetic resonance imaging, ophthalmoscopic findings, treatment onset, improvements in audiometric findings and at speech discrimination tests. Statistical analysis of data was performed. RESULTS: The associate disease group showed higher ages, cerebral microangiopathy observed in magnetic resonance imaging and later improvement in speech discrimination tests, being this difference statistically significant. CONCLUSION: Idiopathic sudden sensorineural hearing loss co-occurring with hypertension, diabetes mellitus or dyslipidemias, in older patients, is associated with a higher prevalence of cerebral microangiopathy, revealed by magnetic resonance imaging, and associated with a slower hearing recovering, showed by later improvements in speech discrimination tests.

Scientific Electronic Library Online (Portuguese)

25

Parâmetros físicos de sedimentos marinhos superficiais da região costeira de Caravelas, Sul da Bahia

Falcão, Lívia Carvalho; Ayres Neto, Arthur
2010-06-01

Resumo em português Este trabalho combina informações obtidas por testemunhos de sondagem com dados adquiridos por perfilagem geofísica a fim de verificar a influência dos parâmetros geológicos e sedimentológicos na velocidade de ondas P em sedimentos marinhos superficiais. Dados de velocidade da onda compressional (Vp), densidade gama, impedância acústica e susceptibilidade magnética foram correlacionados com dados geológicos de quatro testemunhos coletados na zona costeira da ci (mais) dade de Caravelas, estado da Bahia. As propriedades geofísicas foram obtidas utilizando como sistema de medição o perfilador multisensor de testemunhos (MultiSensor Core Logger - MSCL). Os testemunhos foram descritos segundo a geologia, cor e grau de compactação. Oito tipos distintos de sedimentos foram observados: conchas, areia grossa a muito grossa, areia média, areia muito fina a fina, lama arenosa, lama compacta, lama fluida e lama muito fluida. Os resultados mostram que, de maneira geral, os maiores valores de velocidade e densidade, inversamente proporcionais aos de susceptibilidade magnífica, estão associados aos sedimentos de maior granulometria. Os valores de Vp para areia muito grossa e conchas mostrou-se errático devido a falta de compactação desses materiais. Os gráficos de impedância acústica e do coeficiente de reflexão facilitaram a identificação de interfaces e apresentaram coerência em relação aos perfis de velocidade e de densidade. Medições de granulometria foram realizadas na seção de lama arenosa do testemunho JP-112, para ratificar a relação da variabilidade dos parâmetros físicos com a classificação granulométrica utilizada para a caracterização dos quatro testemunhos. Resumo em inglês This research combines geological data obtained from core samples and geophysical properties in order to investigate how geological and sedimentological parameters affect the velocity of P-waves in near surface marine sediments, The velocity of P-waves (Vp), gamma density, acoustic impedance and magnetic susceptibility were correlated with core geology of four core of the coastal region of Caravelas, Bahia State. Geophysical properties were acquired using the MSCL (MultiS (mais) ensor Core Logger). Core were opened and described according to grain size, color, compaction degree. Eight different kinds of sediments were recognized: shell, coarse to very coarse sand, medium sand, fine to very fine sand, sandy mud, compact mud, fluid mud, and very fluid mud. The results showed that, in general, the highest values of Vp and density and the lowest values of magnetic susceptibility are related to the coarser sediments. Very coarse sediments and shells showed erratic values basically due to the low compaction of these materials. The acoustic impedance and reflection coefficient profiles were useful to detect sediments interface. More detailed grain size analysis were conducted at the sandy mud section of core JP-112 and corroborated the relationship between Vp and grain size.

Scientific Electronic Library Online (Portuguese)

26

Osteossarcoma parosteal: aspectos na radiologia convencional/ Parosteal osteosarcoma: conventional radiology findings

Nanci Neto, Francisco; Marchiori, Edson; Vianna, Alberto Domingues; Aymoré, Ierecê Lins; Almeida, Ana Luiza Brito de; Irion, Klaus L.; Collares, Felipe Birchal
2007-04-01

Resumo em português OBJETIVO: Avaliar os achados clínicos mais importantes do osteossarcoma parosteal e descrever os seus aspectos mais comuns na radiologia convencional. MATERIAIS E MÉTODOS: Estudo retrospectivo com 26 pacientes com osteossarcoma parosteal, provenientes do arquivo do Clube do Osso, Rio de Janeiro, RJ, e análise dos principais achados clínicos e aspectos radiológicos. RESULTADOS: A doença predominou em pacientes do sexo feminino e teve idade média de acometimento na t (mais) erceira década de vida. Os achados clínicos mais freqüentes foram o aumento do volume no local do tumor (77% dos casos) e a dor local (68% dos casos). O local mais comum de tumor foi o oco poplíteo, com 40% dos casos, e houve envolvimento metafisário em 92% dos tumores. O aspecto radiológico mais comumente encontrado foi de lesão bem mineralizada e intimamente justaposta à superfície óssea, com o córtex adjacente irregularmente espessado (92,3% dos casos), observando-se área de adesão a este (88,5% dos casos), além de margens tumorais lobuladas (50% dos casos) ou irregulares (38,5% dos casos). Evidenciaram-se, também, linha radiolucente entre o tumor e o osso adjacente (48% dos casos), padrão de mineralização mais denso na base do que na periferia (42,3% dos casos) e pequena ocorrência de reação periosteal (15,4% dos casos). CONCLUSÃO: Apesar de a tomografia computadorizada e a ressonância magnética serem importantes na identificação de alguns aspectos do osteossarcoma parosteal, a radiologia convencional é altamente sugestiva deste tumor e permite, na maior parte dos casos, o diagnóstico diferencial com outras lesões da superfície óssea. Resumo em inglês OBJECTIVE: To evaluate the most significant features of parosteal osteosarcoma and to describe the most frequent findings on conventional radiology. MATERIALS AND METHODS: A retrospective study was performed including 26 cases of patients with parosteal osteosarcoma from the archives of "Clube do Osso", Rio de Janeiro, RJ, Brazil, with analysis of main clinical and radiological findings. RESULTS: The disease was prevalent in female patients in the third decade of life. Ma (mais) in clinical findings were the increase in volume on the site of the tumor (77% of cases) and local pain (68% of cases). The most frequent site of tumor was the popliteal fossa (40%), and metaphyseal involvement has occurred in 92% of cases. The most frequent radiological findings were densely mineralized lesions on juxtacortical locations, and irregularly thickened adjacent host cortex (92.3%), with adherence areas being observed in 88.5% of cases, besides lobular (50%) or irregular (38.5%) tumor margins. Also, a radiolucent line between the tumor and the adjacent bone (48%), a denser mineralization on the basis than in the periphery of the tumor (42.3%), and a small rate of periosteal reaction (15.4%) were found. CONCLUSION: Although computed tomography and magnetic resonance imaging are important modalities for identifying some aspects of parosteal osteosarcoma, conventional x-ray is essential in the initial evaluation of this type of lesion, most frequently allowing differential diagnosis with other surface bone lesions.

Scientific Electronic Library Online (Portuguese)

27

O valor da ultra-sonografia e da ressonância magnética fetal na avaliação das hérnias diafragmáticas/ The value of fetal ultrasonography and magnetic resonance imaging in the assessment of diaphragmatic hernias

Amim, Bruno; Werner Jr., Heron; Daltro, Pedro Augusto; Antunes, Erika; Fazecas, Tatiana; Rodrigues, Leise; Guerra, Fernando; Marchiori, Edson; Gasparetto, Emerson Leandro; Domingues, Romeu Côrtes
2008-02-01

Resumo em português OBJETIVO: Demonstrar a significância dos achados da ressonância magnética e da ultra-sonografia na caracterização pré-natal e avaliação do prognóstico de pacientes com hérnia diafragmática congênita. MATERIAIS E MÉTODOS: Catorze gestantes (idade gestacional média de 28,7 semanas) examinadas com ultra-sonografia e apresentando fetos com suspeita de hérnia diafragmática congênita foram avaliadas por meio da ressonância magnética. Os exames foram realizado (mais) s em aparelho de 1,5 tesla usando seqüências-padrão. Dois radiologistas avaliaram as imagens e estabeleceram os achados por consenso. RESULTADOS: Doze fetos tinham hérnia diafragmática à esquerda e dois, à direita. O fígado fetal foi localizado no interior do tórax de cinco fetos pela ultra-sonografia (três com hérnia diafragmática esquerda e dois com hérnia diafragmática direita) e de oito pela ressonância magnética (seis com hérnia diafragmática esquerda e dois com hérnia diafragmática direita). Herniação do estômago e alças de intestino delgado foi observada em todos os fetos com hérnia diafragmática esquerda (n = 12), tanto pela ultra-sonografia quanto pela ressonância magnética. Oito fetos sobreviveram após cirurgia (sete com hérnia diafragmática esquerda e um com hérnia diafragmática direita). CONCLUSÃO: A ultra-sonografia e a ressonância magnética são métodos de imagens complementares na avaliação das hérnias diafragmáticas congênitas. A ressonância magnética pode auxiliar a ultra-sonografia na avaliação da posição do fígado, o qual representa importante fator prognóstico. Resumo em inglês OBJECTIVE: To demonstrate the relevance of ultrasonography and magnetic resonance imaging findings in the prenatal characterization and prognostic evaluation in cases of congenital diaphragmatic hernia. MATERIALS AND METHODS: Fourteen pregnant women (mean gestational age = 28.7 weeks) who had undergone ultrasonography for suspicion of fetuses with congenital diaphragmatic hernia were assessed by means of magnetic resonance imaging on a 1.5 tesla equipment, following the s (mais) tandard protocol. Two radiologists evaluated the images and the findings were defined by consensus. RESULTS: Twelve fetuses had left diaphragmatic hernia and two, right diaphragmatic hernia. Ultrasonography showed the fetal liver inside the thorax of five fetuses (three with left diaphragmatic hernia, and two with right diaphragmatic hernia) and magnetic resonance imaging in eight fetuses (six with left diaphragmatic hernia, and two with right diaphragmatic hernia). Stomach and small bowel loop herniation was observed in all of the fetuses with left diaphragmatic hernia (n = 12) at both magnetic resonance imaging and ultrasonography. Eight fetuses (seven with left diaphragmatic hernia and one with right diaphragmatic hernia) survived after surgical treatment. CONCLUSION: Ultrasonography and magnetic resonance imaging are complementary imaging methods in the evaluation of congenital diaphragmatic hernia. Magnetic resonance imaging is a helpful diagnostic method complementary to ultrasonography for evaluation of the fetal liver positioning, considering its relevance as a prognostic factor in cases of congenital diaphragmatic hernia.

Scientific Electronic Library Online (Portuguese)

28

O uso da difusão por ressonância magnética na diferenciação das lesões mamárias benignas e malignas/ The use of diffusion-weighted magnetic resonance imaging in the differentiation between benign and malignant breast lesions

Pereira, Fernanda Philadelpho Arantes; Martins, Gabriela; Figueiredo, Eduardo; Domingues, Marisa Nassar Aidar; Domingues, Romeu Côrtes; Fonseca, Lea Mirian Barbosa da
2009-10-01

Resumo em português OBJETIVO: Estudar a utilidade da sequência pesada em difusão na diferenciação das lesões mamárias benignas e malignas. MATERIAIS E MÉTODOS: Quarenta e cinco mulheres (idade média de 46,1 anos) com 52 nódulos de mama foram submetidas a ressonância magnética acrescida da sequência difusão. O coeficiente de difusão aparente (ADC) foi calculado através do mapa de ADC obtido pelo uso de cinco valores de b (0, 250, 500, 750 e 1.000 s/mm²). O valor de ADC médio (mais) de cada lesão foi correlacionado com achados de imagem e resultados histopatológicos. Valores de ADC de corte, sensibilidade e especificidade da sequência difusão na diferenciação das lesões benignas e malignas foram calculados. P Resumo em inglês OBJECTIVE: To study the utility of diffusion-weighted magnetic resonance imaging in the differentiation between benign and malignant breast lesions. MATERIALS AND METHODS: Forty-five women (mean age, 46.1 years) with 52 focal breast lesions underwent diffusionweighted magnetic resonance imaging. The calculation of apparent diffusion coefficient (ADC) was based on the ADC map reflecting five b values (0, 250, 500, 750, and 1000 s/mm²). The mean ADC value of each lesion wa (mais) s correlated with imaging findings and histopathologic results. Cutoff ADC, sensitivity and specificity of diffusion-weighted imaging in the differentiation between benign and malignant lesions were calculated. P

Scientific Electronic Library Online (Portuguese)

29

O papel da colangiografia por ressonância magnética na avaliação da anatomia biliar em doadores de transplante hepático intervivos/ The role of magnetic resonance cholangiography in the evaluation of biliary anatomy in living liver donors

Arruda, Elaine Cristina de Moraes; Coelho, Julio Cezar Uili; Yokochi, Jorge Massayuki; Matias, Jorge Eduardo Fouto
2008-12-01

Resumo em português OBJETIVO: Avaliar a acurácia da colangiografia por ressonância magnética no estudo da anatomia biliar de doadores de fígado em correlação com achados operatórios. MATERIAIS E MÉTODOS: Estudo retrospectivo de 50 doadores submetidos a transplante hepático intervivos no Hospital de Clínicas da Universidade Federal do Paraná, Curitiba, PR. As colangiografias foram analisadas e os resultados dos exames foram comparados com os achados intra-operatórios. Apenas alter (mais) ações anatômicas que promoveram mudança de estratégia cirúrgica, não-evidenciadas previamente pela colangiografia por ressonância magnética, foram consideradas como discordantes. RESULTADOS: Foram encontradas variações pela colangiografia por ressonância magnética em 7 doadores e em 14 durante a cirurgia. Do total de pacientes, 41 resultados foram concordantes e 9 foram discordantes. A sensibilidade, a especificidade, o valor preditivo positivo, o valor preditivo negativo e a acurácia da colangiografia por ressonância magnética foram, respectivamente, de 43%, 97%, 86%, 81% e 81,6%. CONCLUSÃO: Conclui-se que a ressonância magnética é um método de imagem seguro e não-invasivo para avaliação pré-operatória das vias biliares de doadores e que algumas anomalias não são detectadas pela colangiografia por ressonância magnética. Resumo em inglês OBJECTIVE: The present study was aimed at evaluating the accuracy of magnetic resonance cholangiography in the assessment of the biliary anatomy in living liver donors in correlation with surgical findings. MATERIALS AND METHODS: Fifty living liver donors were retrospectively evaluated at Hospital de Clínicas da Universidade Federal do Paraná, Curitiba, PR, Brazil. Cholangiographic images were analyzed and results were compared with intraoperative findings. Only anatomi (mais) cal alterations that affected the surgical strategy and had not been previously observed at magnetic resonance cholangiography were considered as being in disagreement. RESULTS: Anatomical variations were found in 7 donors at magnetic resonance cholangiography, and in 14 during surgery. Agreement between imaging and surgical findings was observed in 41 of the 50 patients, and disagreement in 9. Magnetic resonance cholangiography sensitivity, specificity, positive and negative predictive values, and accuracy were respectively 43%, 97%, 86%, 81% and 81.6%. CONCLUSION: Magnetic resonance imaging is a safe and noninvase method for preoperative evaluation of the biliary tract in living liver donors. However some anatomical abnormalities are not detected by magnetic resonance cholangiography.

Scientific Electronic Library Online (Portuguese)

30

Nióbia magnética como adsorvente de contaminantes orgânicos em meio aquoso: efeito da temperatura e do pH/ Magnetic niobia as adsorbent of organic contaminants in aqueous medium: effect of temperature and pH

Gonçalves, Maraísa; Oliveira, Luiz Carlos Alves; Guerreiro, Mário César
2008-01-01

Resumo em inglês This work describes novel materials based on pure iron oxide and iron oxide/niobia composite to produce a magnetic adsorbent. These materials were prepared with synthetic iron oxide and characterized by powder XRD, SEM, FTIR, TPR and Mössbauer spectroscopy. Results showed that the main iron oxides formed were goethite (aFeOOH) and maghemite (gFe2O3) with small particle size. The iron oxide and iron oxide/niobia composite showed high adsorption ability for organic compounds. The positive enthalpy indicated an endothermic adsorption process suggesting physical adsorption.

Scientific Electronic Library Online (Portuguese)

31

Meduloblastoma: correlação entre ressonância magnética convencional, difusão e espectroscopia de prótons/ Medulloblastoma: correlation among findings of conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy

Fonte, Mariana Vieira de Melo da; Amaral, Raquel Portugal Guimarães; Costa, Maria Olívia Rodrigues; Otaduy, Maria Concepción Garcia; Lucato, Leandro Tavares; Reed, Umbertina Conti; Rosemberg, Sergio; Leite, Claudia da Costa
2008-12-01

Resumo em português OBJETIVO: Correlacionar os achados de ressonância magnética convencional, difusão e espectroscopia de prótons nos meduloblastomas, e compará-los aos dados da literatura. MATERIAIS E MÉTODOS: Análise retrospectiva de exames de ressonância magnética pré-operatórios de nove pacientes na faixa pediátrica com diagnóstico histológico de meduloblastoma (oito desmoplásicos e um de células gigantes). Foram considerados dados demográficos e características do tumo (mais) r como localização, característica morfológica, intensidade de sinal, realce, disseminação e achados na difusão e espectroscopia. RESULTADOS: Na maioria dos casos os tumores apresentaram epicentro no vermis cerebelar (77,8%), sendo predominantemente sólido (88,9%), com hipossinal nas seqüências ponderadas em T1 e iso/hipersinal nas seqüências ponderadas em T2 e FLAIR, realce heterogêneo (100%), sinais de disseminação/extensão tumoral (77,8%) e restrição à movimentação das moléculas de água (100%). A espectroscopia de prótons pela técnica STEAM (n = 6) demonstrou redução da relação Naa/Cr (83,3%) e aumento de Co/Cr (100%) e mI/Cr (66,7%), e pela técnica PRESS (n = 7) evidenciou pico de lactato (57,1%). CONCLUSÃO: O conjunto dos achados macroscópicos obtidos pela ressonância magnética, somado às características bioquímicas dos meduloblastomas, têm sido úteis na tentativa de diferenciação entre os principais tumores da fossa posterior. Resumo em inglês OBJECTIVE: To correlate imaging findings of medulloblastomas at conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy, comparing them with data in the literature. MATERIALS AND METHODS: Preoperative magnetic resonance imaging studies of nine pediatric patients with histologically confirmed medulloblastomas (eight desmoplastic medulloblastoma, and one giant cell medulloblastoma) were retrospectively reviewed, conside (mais) ring demographics as well as tumors characteristics such as localization, morphology, signal intensity, contrast-enhancement, dissemination, and diffusion-weighted imaging and spectroscopy findings. RESULTS: In most of cases the tumors were centered in the cerebellar vermis (77.8%), predominantly solid (88.9%), hypointense on T1-weighted images and intermediate/hyperintense on T2-FLAIR-weighted images, with heterogeneous enhancement (100%), tumor dissemination/extension (77.8%) and limited water molecule mobility (100%). Proton spectroscopy acquired with STEAM technique (n = 6) demonstrated decreased Naa/Cr ratio (83.3%) and increased Co/Cr (100%) and mI/Cr (66.7%) ratios; and with PRESS technique (n = 7) demonstrated lactate peak (57.1%). CONCLUSION: Macroscopic magnetic resonance imaging findings in association with biochemical features of medulloblastomas have been useful in the differentiation among the most frequent posterior fossa tumors.

Scientific Electronic Library Online (Portuguese)

32

Magneto-V1: um programa para o cálculo de correções diamagnéticas e de momentos magnéticos efetivos/ Magneto-V1: a program for the calculation of diamagnetic corrections and effective magnetic moments

Friedermann, Geraldo Roberto; Nunes, Giovana Gioppo; Soares, Jaísa Fernandes
2005-03-01

Resumo em inglês A new computer program has been developed to help the users of force methods for magnetic moment determination. It provides a user-friendly interface for the calculation of corrected magnetic susceptibilities of paramagnetic materials and enables the user to simulate a number of chemical formulations for the sample under study. The program is written in the Perl scripting language and runs on a Unix platform.

Scientific Electronic Library Online (Portuguese)

33

Linfoma não-Hodgkin apresentando-se como massa hepática única/ Non-Hodgkin's lymphoma presenting as a single liver mass

Peixoto, Mila Correia Góis; Peixoto Filho, Anibal Araújo Alves; Ribeiro, Alessandra Caivano Rodrigues; D'Ippolito, Giuseppe
2009-02-01

Resumo em português OBJETIVO: Descrever as principais características de imagem do linfoma não-Hodgkin apresentando-se como massa hepática única. MATERIAIS E MÉTODOS: Realizamos estudo retrospectivo mediante análise de casos de pacientes com massa hepática única aos exames de ultrassonografia, tomografia computadorizada e ressonância magnética, com diagnóstico histológico de linfoma não-Hodgkin. Esses exames foram analisados por dois examinadores em consenso. RESULTADOS: Identif (mais) icamos três pacientes, todos do sexo masculino, na quinta década de vida, com quadro clínico inespecífico e que apresentavam massa hepática única e com diagnóstico de linfoma não-Hodgkin. Na ultrassonografia a lesão hepática apresentava-se como massa com aspecto "em alvo" nos três casos estudados. Na tomografia computadorizada observou-se massa hipodensa e heterogênea, com realce anelar em todos os casos. Na ressonância magnética as lesões apresentavam-se heterogêneas, hipointensas em T1 e hiperintensas em T2, e também com realce anelar após a injeção do contraste. Nenhum paciente apresentava linfonodomegalia ou comprometimento de outras vísceras sólidas no momento do diagnóstico. CONCLUSÃO: Na presença de massa hepática solitária e com aspecto "em alvo" deve-se considerar, entre as hipóteses, o diagnóstico de linfoma. Resumo em inglês OBJECTIVE: To describe the main imaging findings of non-Hodgkin's lymphoma presenting as a single liver mass. MATERIALS AND METHODS: A retrospective study was developed with analysis of cases where a single liver mass was observed at ultrasonography, computed tomography and magnetic resonance imaging, and histologically diagnosed as non-Hodgkin's lymphoma. The studies were reviewed by two observers in consensus. RESULTS: Three male patients in the fifth decade of life, wi (mais) th non-specific clinical manifestations and single liver mass diagnosed as non-Hodgkin's lymphoma were identified. A hepatic lesion with target sign was observed at ultrasonography in all of the cases. At computed tomography, all the patients presented a heterogeneous, hypodense mass with a ring enhancement. At magnetic resonance imaging, the lesions were heterogeneous and hypointense on T1-weighted and hyperintense on T2-weighted images. Additionally, a ring enhancement was observed in all of the cases after contrast injection. At the moment of the diagnosis, none of the patients presented lymphadenomegaly or involvement of other solid viscera. CONCLUSION: The diagnosis of hepatic lymphoma should be considered in the presence of a ring-enhanced single liver mass.

Scientific Electronic Library Online (Portuguese)

34

Ligas Finemet nanocristalizadas a partir de precursores amorfos

Mariano, Neide Aparecida; May, José Eduardo; Kuri, Sebastião Elias
2004-06-01

Resumo em português Atualmente, há muito interesse no desenvolvimento de materiais nanocristalinos e amorfos, que apresentem alta resistência mecânica combinada com boa ductilidade, abrindo grandes perspectivas tecnológicas para o processamento desses materiais. Devido a sua versatilidade, as ligas amorfas têm mostrado ter propriedades que podem ser utilizadas em diversas áreas, como em memórias de computadores, aplicações em vários tipos de transformadores para potência e usos el (mais) etrônicos. A técnica para obter as ligas amorfas utilizada nesse trabalho foi a de solidificação rápida a partir do estado líquido, por melt spinning. O processamento das fitas foi efetuado em duas etapas, inicialmente foi realizado a fusão da liga por indução magnética, posteriormente, a liga foi submetida a nova refusão para melhorar a homogeneização e, em seguida, produziu-se a fita metálica amorfa, utilizando uma taxa de resfriamento em torno de 10³°C/s. Durante o processamento, a fita obtida apresentou-se amorfa e com uma espessura em torno de 25µm. Resumo em inglês Now, there is a lot of interest in the development of nanocrystalline and amorphous materials, that present high mechanical resistance combined with good ductility, opening great technological perspectives for the processing these of materials. Due to its versatility, the amorphous alloys have been showing to have properties that can be used in several areas, as in memory of computers, applications in several types of transformers for potency and electronic uses. The tech (mais) nique used to obtain of amorphous alloys in this work, it went to of rapid solidification starting from the liquid state, for melt spinning. The processing of the ribbons of was made in two stages, initially the coalition of the alloy was accomplished by magnetic induction, later on, the alloy was submitted the new remelting to improve the homogenizationand soon after, the amorphous metallic ribbon was produced, used of the high cooling rate, around 10³°C/s. During the processing, the obtained ribbon came amorphous and with a thickness around 25µm.

Scientific Electronic Library Online (Portuguese)

35

Hipnose para controle de claustrofobia em exames de ressonância magnética/ Hypnosis for management of claustrophobia in magnetic resonance imaging

Velloso, Luiz Guilherme Carneiro; Duprat, Maria de Lourdes; Martins, Ricardo; Scoppetta, Luiz
2010-02-01

Resumo em português OBJETIVO: Testar a eficácia da hipnose para o controle de claustrofobia em pacientes submetidos a exames de ressonância magnética. MATERIAIS E MÉTODOS: Vinte pacientes claustrofóbicos, com indicação de sedação para ressonância magnética, foram submetidos a hipnose pela técnica de Braid. Os pacientes suscetíveis à hipnose foram encaminhados para realização do exame em estado de transe hipnótico, sem uso de medicamentos para sedação. RESULTADOS: Da amostr (mais) a estudada, 18 casos (90%) foram suscetíveis à técnica. Dos 16 pacientes sensíveis à hipnose que compareceram para a ressonância magnética, 15 (93,8%) realizaram o exame em transe hipnótico, sem ocorrência de crise de claustrofobia e sem necessitar de medicamentos para sedação. CONCLUSÃO: Hipnose é uma alternativa para a sedação medicamentosa em pacientes claustrofóbicos que necessitam realizar ressonância magnética. Resumo em inglês OBJECTIVE: To evaluate the efficacy of hypnosis for management of claustrophobia in patients submitted to magnetic resonance imaging. MATERIALS AND METHODS: Twenty claustrophobic patients referred for magnetic resonance imaging under sedation were submitted to hypnosis using the Braid technique. The patients susceptible to hypnosis were submitted to magnetic resonance imaging under hypnotic trance without using sedative drugs. RESULTS: Out of the sample, 18 (90%) patients (mais) were susceptible to the technique. Of the 16 hypnotizable subjects who were submitted to magnetic resonance imaging, 15 (93.8%) could complete the examination under hypnotic trance, with no sign of claustrophobia and without need of sedative drugs. CONCLUSION: Hypnosis is an alternative to anesthetic sedation for claustrophobic patients who must undergo magnetic resonance imaging.

Scientific Electronic Library Online (Portuguese)

36

Ferritas Ni-Zn: breve revisão sobre o processo convencional de fabricação e as propriedades permeabilidade magnética e constante dielétrica/ Ni-Zn ferrites: brief review on the conventional method of fabrication and the magnetic permeability and dielectric constant properties

Brito, V. L. O.
2006-12-01

Resumo em português As ferritas Ni-Zn são cerâmicas magnéticas que têm sido amplamente aplicadas na fabricação de componentes elétricos e eletrônicos. Esses materiais têm sido estudados há décadas por diversos autores, os quais têm definido a relação entre as propriedades magnéticas e elétricas dessas ferritas em função de diversos fatores, tais como as variáveis do processo de fabricação, composição química e microestrutura. Este trabalho mostra uma revisão dos prin (mais) cipais fatores que influenciam as propriedades das ferritas Ni-Zn, com foco na permeabilidade magnética e constante dielétrica e enfatizando as características do método cerâmico convencional na fabricação desses materiais. Resumo em inglês Ni-Zn ferrites are magnetic ceramics that have been widely used on the fabrication of electrical and electronic components. Such materials have been studied for many years by several researchers and their magnetic and electrical properties have been assessed in relation to many factors, such as chemical composition, fabrication methods, and microstructure. This work makes a review of the main factors influencing the properties of Ni-Zn ferrites. It is emphasized the magne (mais) tic permeability and dielectric constant, as well as the characteristics of the conventional ceramic method on the fabrication of these ferrites.

Scientific Electronic Library Online (Portuguese)

37

Estudo da circulação hepatomesentérica pela angiografia por ressonância magnética com gadolínio: comparação entre doses simples e dupla no estudo de pacientes esquistossomóticos/ Gadolinium-enhanced magnetic resonance angiography for hepatomesenteric vascular evaluation: single and double doses comparison in schistosomiasis patients

Caldana, Rogério Pedreschi; Bezerra, Alexandre Sérgio de Araújo; D'Ippolito, Giuseppe; Szejnfeld, Jacob
2006-08-01

Resumo em português OBJETIVO: Determinar a freqüência de visualização dos segmentos da circulação hepatomesentérica pela angiografia por ressonância magnética (angio-RM) com contraste e comparar o valor do método, utilizando-se duas diferentes dosagens de gadolínio (doses simples e dupla). MATERIAIS E MÉTODOS: Estudo prospectivo de 36 pacientes esquistossomóticos submetidos a angio-RM. Os exames foram realizados em equipamento de RM de 1,5 T, usando-se bobina de corpo e bomba in (mais) jetora para a administração endovenosa do contraste. Foram utilizadas, de maneira randomizada, dose dupla do contraste paramagnético (0,2 mmol/kg de Gd-DTPA) em 21 pacientes e dose simples (0,1 mmol/kg) em outros 15 pacientes. Os exames foram interpretados por dois observadores em consenso, que classificaram o grau de visualização de 25 segmentos vasculares estabelecidos para análise, sem conhecimento da dose de gadolínio utilizada. RESULTADOS: Os segmentos vasculares proximais e de maior calibre foram as estruturas com melhor grau de visualização na maioria da amostra em estudo. O tronco celíaco, a artéria hepática comum, a artéria esplênica, a croça e terço médio da artéria mesentérica superior, a veia porta, a veia esplênica e a veia mesentérica superior apresentaram grau 2 de visualização em mais de 70% da amostra. Quanto à comparação das diferentes dosagens, não houve diferença significante (p Resumo em inglês OBJECTIVE: To evaluate the visibility of hepatomesenteric vascular segments by 3D gadolinium-enhanced magnetic resonance (MR) angiography and to compare the method effectiveness between two different gadolinium doses (single and double doses). MATERIALS AND METHODS: A prospective study was performed with 36 schistosomiasis patients who were submitted to 3D contrast-enhanced MR angiography. Scans were performed in a high-field equipment (1.5 T), with body coil and power in (mais) jector for intravenous contrast administration. Contrast double doses (Gd-DTPA 0.2 mmol/kg) and single doses (0.1 mmol/kg) were randomly used respectively in 21 and 15 patients. Studies were interpreted by consensus between two observers who have rated the visualization degree of 25 proximal vascular segments without knowing the dose used. RESULTS: Proximal and calibrous vascular segments have presented higher visualization degree in the greatest part of the sample studied. The celiac trunk, common hepatic artery, splenic artery, proximal and medium third of superior mesenteric artery, portal vein, splenic vein and superior mesenteric vein have presented grade 2 visualization in more than 70% of the sample studied. As regards comparison between different doses, there was no significant difference (p

Scientific Electronic Library Online (Portuguese)

38

Estudo comparativo das seqüências rápidas ponderadas em T2, utilizando-se sincronização respiratória, apnéia, supressão de gordura, bobina de corpo e bobina de sinergia para a avaliação do fígado pela ressonância magnética/ Comparative study of fast T2-weighted images using respiratory triggered, breath-hold, fat suppression and phased array multicoil for liver evaluation by magnetic resonance imaging

Abbehusen, Cristiane L.; D'Ippolito, Giuseppe; Palácio, Glaucia A.S.; Szejnfeld, Jacob
2003-10-01

Resumo em português OBJETIVO: Comparar, qualitativa e quantitativamente, as imagens de ressonância magnética do fígado, ponderadas em T2, utilizando-se seqüências rápidas, diferenciadas pela técnica de controle respiratório, pela utilização de supressão de gordura e pelo tipo de bobina de radiofreqüência. MATERIAIS E MÉTODOS: Estudo prospectivo em 71 pacientes consecutivos, sendo realizadas seis seqüências para comparação: 1) supressão de gordura com sincronização respir (mais) atória e bobina de corpo; 2) supressão de gordura em apnéia e bobina de corpo; 3) sem supressão de gordura com sincronização respiratória e bobina de corpo; 4) sem supressão de gordura em apnéia e bobina de corpo; 5) com supressão de gordura com sincronização respiratória e bobina de sinergia; 6) com supressão de gordura em apnéia e bobina de sinergia. A avaliação qualitativa foi baseada em três critérios: detecção de determinadas estruturas anatômicas do fígado, definição dos contornos hepáticos, e presença de artefatos de respiração. A análise quantitativa foi obtida através da relação das intensidades de sinal do fígado e do ruído de fundo. RESULTADOS: O valor médio dos índices globais de qualidade de imagem para cada uma das seis seqüências supracitadas foi de 7,8, 4,6, 7,9, 5,2, 6,7 e 4,6, respectivamente. As seqüências obtidas com sincronização respiratória apresentaram melhor qualidade de imagem e relação sinal/ruído superiores às seqüências com apnéia (p 0,05). As seqüências obtidas com bobina de sinergia apresentaram qualidade de imagem semelhante (p > 0,05) e relação sinal/ruído inferior àquelas com bobina de corpo (p Resumo em inglês OBJECTIVE: To compare both qualitatively and quantitatively six T2-weigthed turbo spin-echo sequences varying the respiratory compensation technique, associating or not fat tissue suppression and using different types of coils. MATERIALS AND METHODS: We performed a prospective study of 71 consecutive patients that were submitted to MRI of the liver using a 1.5T magnet. The six following pulse sequences were used: 1) fat-suppressed respiratory triggered with conventional b (mais) ody coil; 2) breath-hold fat-suppressed with conventional body coil; 3) non-suppressed respiratory triggered with conventional body coil; 4) breath-hold non fat-suppressed with conventional body coil; 5) fat-suppressed respiratory triggered with phased-array multicoil; 6) breath-hold fat-suppressed with phased-array multicoil. Images were analyzed quantitatively by measuring the signal-to-noise ratios and qualitatively by evaluating the sharpness of hepatic contours, visibility of intrahepatic vessels and other segmental landmarks, and the presence of artifacts. RESULTS: The qualitative analysis showed that the mean values obtained with the six sequences were 7.8, 4.6, 7.9, 5.2, 6.7 and 4.6, respectively. The respiratory-triggered sequences were better than the breath-hold sequences in both qualitative and quantitative analysis (p 0.05). The sequences using the body coil were similar in terms of image quality (p > 0.05) and better regarding signal-to-noise ratios than those obtained with the phased-array multicoil (p

Scientific Electronic Library Online (Portuguese)

39

Espumados magnetizáveis úteis em processos de recuperação ambiental/ Magnetic foams useful in the environmental recovery processes

Lopes, Magnovaldo C; Souza Jr, Fernando G. de; Oliveira, Geiza E
2010-01-01

Resumo em português A produção de biodiesel foi incentivada pelo desejo de se obter fontes energéticas de origem diferente do petróleo. Este processo, contudo, gera grandes quantidades de glicerina como subproduto. Assim, novas aplicações devem ser encontradas para esta glicerina evitando o colapso da cadeia nacional produtiva de glicerina animal. Uma aplicação mais nobre para esta glicerina, proveniente da indústria de biodiesel, é a produção de resinas alquídicas. Estas resina (mais) s podem ser utilizadas como matrizes de compósitos para recuperação de ambientes aquáticos impactados por acidentes de derrames de petróleo. Outra aplicação para estes materiais é na remoção e limpeza de águas produzidas e águas de refinaria, visando a atender a legislação ambiental. Neste trabalho, nanocompósitos espumados magnetizáveis foram preparados pela inserção de nanopartículas magnetizáveis em uma matriz de resina alquídica, obtida a partir da glicerina oriunda do óleo de mamona. Os materiais produzidos foram caracterizados por FTIR-ATR, DRX e SAXS. Além disso, a força magnética destes materiais foi estudada bem como a capacidade de remoção de petróleo derramado sobre água. Os resultados são animadores, pois demonstram a obtenção de um nanocompósito que possui força magnética relativa superior à da maguemita pura. Além disso, este nanocompósito é capaz de remover massas de petróleo cerca de 300% superiores às massas do material usado. Estes materiais, portanto, consistem em uma potencial ferramenta para a recuperação de ambientes aquáticos impactados por acidentes de derramamento de petróleo. Resumo em inglês The biodiesel production was encouraged since the entire world is looking for new energy sources. However, the biodiesel process produces large amounts of glycerin as byproduct. Therefore, innovative uses for this new glycerin source must be sought so as to avoid the collapse of the animal glycerin chain. In this context, the production of resins is interesting due to the likeness between these polymers and the petroleum, with these resins being promising as spill cleanup (mais) agents. In the present work, magnetic foams were prepared with insertion of maghemite nanoparticles into in a polymer generated from the glycerin, and were characterized using FTIR-ATR, WAXD and SAXS techniques. In addition, the magnetic force and the oil removal capability of these materials were also studied. The results are encouraging because nanocomposites were obtained which possess magnetic forces larger than for pure maghemite. Furthermore, this nanocomposite is able to remove a petroleum mass around 300% larger than the used mass of the composite, which means that the composite may be important for avoiding environmental disasters owing to the oil spill on the water.

Scientific Electronic Library Online (Portuguese)

40

Espectroscopia por ressonância magnética no diagnóstico do câncer de próstata: experiência inicial/ Magnetic resonance spectroscopy imaging in the diagnosis of prostate cancer: initial experience

Melo, Homero José de Farias e; Szejnfeld, Denis; Paiva, Cristiano Silveira; Abdala, Nitamar; Arruda, Homero Oliveira de; Goldman, Suzan Menasce; Szejnfeld, Jacob
2009-02-01

Resumo em português OBJETIVO: Demonstrar a experiência na implantação de um protocolo de espectroscopia por ressonância magnética do 1H tridimensional (3D 1H MRSI), disponível comercialmente, aplicando-o em pacientes com suspeita de neoplasia prostática e com diagnóstico estabelecido de tumor prostático. MATERIAIS E MÉTODOS: Estudo realizado de forma prospectiva, em 41 pacientes com idades entre 51 e 80 anos (média de 67 anos). Dois grupos foram formados: pacientes com uma ou mais (mais) biópsias negativas para câncer e antígeno prostático específico elevado (grupo A) e pacientes com câncer confirmado por biópsia (grupo B). Procurou-se, a partir dos resultados da ressonância magnética e espectroscopia por ressonância magnética, determinar a área-alvo (grupo A) ou a extensão do câncer conhecido (grupo B). RESULTADOS: No diagnóstico de câncer de próstata a espectroscopia por ressonância magnética apresentou especificidade abaixo da descrita pela literatura, cerca de 47%. Já para o estadiamento do tumor diagnosticado, houve correspondência com a literatura. CONCLUSÃO: A implantação e padronização da espectroscopia por ressonância magnética permitiram a obtenção de informações importantes para o diagnóstico presuntivo da existência de câncer de próstata, combinando as imagens por ressonância magnética com os dados metabólicos da espectroscopia por ressonância magnética. Resumo em inglês OBJECTIVE: To report an experiment involving the introduction of a protocol utilizing commercially available three-dimensional 1H magnetic resonance spectroscopy imaging (3D 1H MRSI) method in patients diagnosed with prostatic tumors under suspicion of neoplasm. MATERIALS AND METHODS: Forty-one patients in the age range between 51 and 80 years (mean, 67 years) were prospectively evaluated. The patients were divided into two groups: patients with one or more biopsies negat (mais) ive for cancer and high specific-prostatic antigen levels (group A), and patients with cancer confirmed by biopsy (group B). The determination of the target-area (group A) or the known cancer extent (group B) was based on magnetic resonance imaging and MRSI studies. RESULTS: The specificity of MRSI in the diagnosis of prostate cancer was lower than the specificity reported in the literature (about 47%). On the other hand, for tumor staging, it corresponded to the specificity reported in the literature. CONCLUSION: The introduction and standardization of 3D 1H MRSI has allowed the obtention of a presumable diagnosis of prostate cancer, by a combined analysis of magnetic resonance imaging and metabolic data from 3D 1H MRSI.

Scientific Electronic Library Online (Portuguese)

41

Espectroscopia de prótons e perfusão por ressonância magnética na avaliação dos tumores do sistema musculoesquelético/ Proton magnetic resonance spectroscopy and perfusion magnetic resonance imaging in the evaluation of musculoskeletal tumors

Costa, Flávia Martins; Vianna, Evandro Miguelote; Domingues, Rômulo Côrtes; Setti, Marcela; Meohas, Walter; Rezende, José Francisco; Domingues, Romeu Côrtes; Gasparetto, Emerson Leandro
2009-08-01

Resumo em português OBJETIVO: Avaliar a espectroscopia de prótons e o estudo dinâmico do contraste por ressonância magnética na diferenciação dos tumores musculoesqueléticos benignos e malignos. MATERIAIS E MÉTODOS: Foram estudados 55 pacientes com tumores musculoesqueléticos (27 malignos e 28 benignos). Os exames foram realizados em aparelho de ressonância magnética de 1.5 T com protocolo convencional e espectroscopia de prótons com TE de 135 ms. O estudo dinâmico do contraste (mais) foi adquirido pela sequência T1 gradiente-eco após a administração intravenosa de gadolínio. Curvas de intensidade de sinal versus tempo e valores de slope foram calculados. A análise estatística foi realizada pelo teste de Levene, seguido pelo teste t de Student, além dos testes qui-quadrado de Pearson e exato de Fischer. RESULTADOS: A sensibilidade, especificidade e acurácia da espectroscopia de prótons foram, respectivamente, de 87,5%, 92,3% e 90,9% (p Resumo em inglês OBJECTIVE: To assess the role of proton magnetic resonance spectroscopy and dynamic contrast-enhanced magnetic resonance imaging in the differentiation between malignant and benign musculoskeletal tumors. MATERIALS AND METHODS: Fifty-five patients with musculoskeletal tumors (27 malignant and 28 benign) were studied. The examinations were performed in a 1.5 T magnetic resonance scanner with standard protocol, and single voxel proton magnetic resonance spectroscopy with 13 (mais) 5 msec echo time. The dynamic contrast study was performed using T1-weighted gradient-echo sequence after intravenous gadolinium injection. Timesignal intensity curves and slope values were calculated. The statistical analysis was performed with the Levene's test, followed by a Student's t-test, besides the Pearson's chi-squared and Fischer's exact tests. RESULTS: Proton magnetic resonance spectroscopy sensitivity, specificity and accuracy were, respectively, 87.5%, 92.3% and 90.9% (p

Scientific Electronic Library Online (Portuguese)

42

Enterografia peroral por tomografia computorizada: avaliação da patologia do intestino delgado por tomografia computorizada multicorte com contraste oral de goma de alfarroba-sorbitol

Barata, M. J.; Lourenço, R.; Capacho, A. S.; Fonseca, J.; Cyrne, C.
2006-05-01

Resumo em português Introdução: O estudo do intestino delgado tem evoluído extraordinariamente, mas ainda não está definido um método referencial. Descreve-se a utilização em Tomografia Computorizada de um contraste oral usado em Ressonância Magnética. Objectivos: Avaliação da Enterografia Peroral por Tomografia Computorizada com goma de alfarroba-sorbitol no estudo do intestino delgado. Material e Métodos: Doze doentes realizaram Enterografia Peroral por Tomografia Computorizad (mais) a: 7 por suspeita de doença de Crohn, 2 para estudo de doença de Crohn conhecida e 3 por hemorragia digestiva e/ou anemia. Efectuouse o estudo num aparelho multicorte, após admnistração endovenosa de contraste iodado, com distensão prévia do intestino com solução oral hiperosmolar (goma de alfarroba-sorbitol). Avaliou-se: tolerância, distensibilidade intestinal e acuidade diagnóstica deste método. Resultados: O exame foi bem tolerado em todos os doentes. Confirmou o diagnóstico de doença de Crohn em 4, avaliou complicações desta doença em 2, diagnosticou tumores no delgado em 1 e no cólon em 1. A distensibilidade intestinal foi boa ou óptima em todos. Registaram-se apenas complicações minor do contraste oral: desconforto abdominal em 1 e diarreia em 3. Conclusões: A Enterografia Peroral por Tomografia Computorizada com goma de alfarroba-sorbitol revelou-se uma técnica simples, bem tolerada e útil no estudo do intestino delgado. Resumo em inglês Introduction: Despite advances in the study of the small bowel, a gold standard method has not yet been defined. Here we report our experience with Computed Tomography with an oral contrast material used for Magnetic Resonance Imaging. Purpose: To assess Computed Tomographic Enterography with locust bean gum-sorbitol in evaluating the small bowel. Materials and Methods: Twelve patients underwent Computed Tomographic Enterography: 7 suspected of having Crohn’s disease, 2 (mais) for assessment of known Crohn’s disease and 3 with gastrointestinal bleeding/anemia. After intravenous administration of iodinated contrast material and prior small bowel distension using an osmotic oral contrast material (locust bean gum-sorbitol), images were obtained with a multi-detector row helical computed tomography scanner. We assessed: i) patients tolerance, ii) small bowel distension and iii) accuracy of this method. Results: Computed Tomographic Enterography was well tolerated in all patients. It diagnosed Crohn’s disease in 4 patients, helped assess complications of the disease in 2 and detected tumours in the small bowel in 1 and in the colon in 1. The degree of small bowel distension was good or optimal in all cases. The patients reported minor side effects associated with the oral contrast material: abdominal pain in 1 and diarrhea in 3. Conclusion: Computed Tomographic Enterography with locust bean gum-sorbitol is a simple, non-invasive and effective method of evaluating the small bowel.

Scientific Electronic Library Online (Portuguese)

43

Endometriose pélvica: comparação entre imagens por ressonância magnética de baixo campo (0,2 T) e alto campo (1,5 T)/ Pelvic endometriosis: a comparison between low-field (0.2 T) and high-field (1.5 T) magnetic resonance imaging

Minaif, Karine; Shigueoka, David Carlos; Minami, Cintia Cristina Satie; Sales, Danilo Moulin; Ruano, José Maria Cordeiro; Noguti, Alberto Sinhiti; Ajzen, Sergio; Szejnfeld, Jacob
2008-12-01

Resumo em português OBJETIVO: Comparar a ressonância de baixo campo (0,2 T) com a de alto campo (1,5 T) na avaliação da endometriose pélvica e adenomiose. MATERIAIS E MÉTODOS: Foram estudadas, prospectivamente, 27 pacientes do sexo feminino com suspeita clínica de endometriose, realizando-se exames de ressonância magnética de alto campo e baixo campo. Um mesmo radiologista realizou a leitura dos exames, iniciando pelo baixo campo, seguido pelo alto campo, usando como padrão-ouro o a (mais) lto campo. RESULTADOS: Das 27 pacientes estudadas, 18 (66,7%) apresentaram alguma lesão indicativa de endometriose nos exames realizados no alto campo. Foram corretamente diagnosticados pelo baixo campo 14 destas pacientes. Endometriomas, lesões tubárias e focos de endometriose maiores do que 7 mm identificados pelo alto campo foram também identificados no baixo campo, com acurácia, sensibilidade e especificidade de 100%. Das nove pacientes com adenomiose caracterizadas pelo alto campo, oito foram corretamente identificadas pelo baixo campo, com acurácia, sensibilidade e especificidade de 88,9%. CONCLUSÃO: A ressonância de baixo campo apresentou baixa sensibilidade na detecção de pequenos focos de endometriose, alta sensibilidade na detecção de endometriomas e focos de endometriose grandes, e boa acurácia na detecção da adenomiose quando comparada com a ressonância de alto campo. Resumo em inglês OBJECTIVE: To compare low-field (0.2 T) with high-field (1.5 T) magnetic resonance imaging in the assessment of pelvic endometriosis and adenomyosis. MATERIALS AND METHODS: Twenty-seven female patients with clinically suspected endometriosis were prospectively evaluated by means of high-field and low-field magnetic resonance imaging. The reading of the images was performed by a single radiologist, initiating by the low-field, followed by the high-field images. High-field (mais) magnetic resonance imaging was utilized as the golden-standard. RESULTS: Among the 27 patients included in the present study, 18 (66.7%) had some type of lesion suggesting the presence of endometriosis demonstrated at high-field images. In 14 of these patients the diagnosis was correctly established by low-field magnetic resonance imaging. Endometriomas, tubal lesions, and endometriotic foci > 7 mm identified at the high-field images were also identified at low-field images with 100% accuracy, sensitivity and specificity. Among the nine patients diagnosed with adenomyosis by high-field images, eight were correctly diagnosed by low-field images with 88.9% accuracy, specificity and sensitivity. CONCLUSION: Low-field magnetic resonance imaging demonstrated a low sensitivity in the detection of small endometriotic foci, high sensitivity in the detection of endometriomas and large endometriotic foci, and high accuracy in the detection of adenomyosis when compared with high-field magnetic resonance imaging.

Scientific Electronic Library Online (Portuguese)

44

Diferenciação entre cisto simples e hemangioma hepático utilizando seqüência de ressonância magnética ponderada em T2 com técnica gradiente-eco (B-FFE)/ Differentiation between simple cyst and hepatic hemangioma utilizing T2-weighted magnetic resonance imaging with gradient-echo (b-FFE) technique

Burim, Carolina Valente; Pecci Neto, Luiz; Torlai, Fabiola Goda; Tiferes, Dario Ariel; D'Ippolito, Giuseppe
2008-12-01

Resumo em português OBJETIVO: Estabelecer o valor das seqüências ponderadas em T2 para diferenciar cistos simples de hemangiomas hepáticos. MATERIAIS E MÉTODOS: Estudo prospectivo, observacional, transversal e duplo-cego em 52 pacientes com 91 lesões hepáticas (34 cistos simples e 57 hemangiomas) submetidos a ressonância magnética de abdome. A análise conjunta de todas as seqüências realizadas foi considerada o padrão-ouro. Dois observadores independentes avaliaram, subjetivament (mais) e, as seqüências TSE com TE longo e B-FFE, procurando diferenciar cistos de hemangiomas. Foram calculadas a eficácia das seqüências e a concordância interobservador e intra-observador por meio do teste kappa (κ) (p Resumo em inglês OBJECTIVE: To establish the role of MRI T2-weighted sequences in the differentiation between simple cysts and hepatic hemangiomas. MATERIALS AND METHODS: A double-blinded, prospective, observational, cross-sectional study evaluated 52 patients with 91 hepatic lesions (34 simple cysts and 57 hemangiomas) submitted to abdominal magnetic resonance imaging. The combined analysis of all sequences was considered as the golden-standard. TSE sequences with long echo trains and b- (mais) FFE sequences were subjectively analyzed by two independent observers for differentiating cysts from hemangiomas. The kappa test (κ) was utilized in the analysis of the methods accuracy and inter- and intra-observer agreement (p

Scientific Electronic Library Online (Portuguese)

45

Diagnóstico por imagem e aspectos clínicos da trombose venosa cerebral em recém-natos a termo sem dano cerebral: revisão em 10 anos/ Imaging diagnosis and clinical findings of cerebral venous thrombosis in full-term neonates without brain damage: a ten-year review

Monteiro, Alexandra Maria Vieira; Lima, Claudio Marcio Amaral de Oliveira; Ribeiro, Érica Barreiros; Lins, Maria Cristina; Miranda, Silvia; Miranda, Luis Eduardo
2010-06-01

Resumo em português OBJETIVO: Descrever e comparar os métodos de imagem e os aspectos clínicos em quatro recém-natos a termo diagnosticados como trombose venosa cerebral, sem dano encefálico, adscritos a uma unidade de terapia intensiva neonatal. MATERIAIS E MÉTODOS: Revisão em 10 anos com quatro casos diagnosticados como trombose venosa cerebral por meio de ultrassonografia transfontanela com Doppler e confirmados por ressonância magnética/angiorressonância, correlacionados aos asp (mais) ectos clínicos e evolução neurológica. RESULTADOS: A ultrassonografia foi normal em 75% dos casos e a ressonância magnética, em 100%. No caso alterado, a dilatação venosa foi identificada. O Doppler e a angiorressonância estavam alterados em 100% dos casos. Dos aspectos clínicos, a hipóxia (100%) e a convulsão precoce (100%) predominaram, com potencial evocado alterado em 50% dos casos. Na avaliação do neurodesenvolvimento, todas as áreas estiveram dentro da normalidade até a última avaliação. CONCLUSÃO: A ultrassonografia associada ao Doppler é capaz de identificar as alterações da trombose venosa cerebral, devendo ser complementada com a ressonância magnética, que é o padrão ouro de diagnóstico. Resumo em inglês OBJECTIVE: To describe and compare imaging methods and clinical findings of cerebral venous thrombosis in four full-term neonates without brain damage, admitted to a neonatal intensive care unit. MATERIALS AND METHODS: Ten-year review of four cases diagnosed with cerebral venous thrombosis by transfontanellar ultrasonography associated with Doppler fluxometry and confirmed by magnetic resonance imaging/magnetic resonance angiography in correlation with clinical findings a (mais) nd neurological progression. RESULTS: Ultrasonography presented normal results in 75% of cases and magnetic resonance imaging in 100%. Doppler fluxometry and magnetic resonance angiography were abnormal in 100% of cases. Hypoxia (100%) and early seizures (100%) were predominant among clinical findings with evoked potential changes in 50% of cases. In the assessment of the neurodevelopment all the areas remained within normality parameters up to the conclusion of the present study. CONCLUSION: Ultrasonography in association with Doppler can identify changes related to cerebral venous thrombosis and should be complemented with magnetic resonance imaging that is the gold standard for diagnosis in these cases.

Scientific Electronic Library Online (Portuguese)

46

Correlação interobservador das alterações morfológicas das vias biliares em pacientes com esquistossomose mansoni pela colangiorressonância magnética/ Evaluation of morphological changes of the biliary tree by magnetic resonance cholangiography in patients with schistosomiasis mansoni: interobserver agreement

Sales, Danilo Moulin; Santos, José Eduardo Mourão dos; Shigueoka, David Carlos; Leão, Alberto Ribeiro de Souza; Colleoni Neto, Ramiro; Borges, Durval Rosa; D'Ippolito, Giuseppe; Szejnfeld, Jacob
2009-10-01

Resumo em português OBJETIVO: Descrever as alterações das vias biliares pela colangiografia por ressonância magnética (CPRM) na esquistossomose hepatoesplênica e avaliar a concordância interobservador da CPRM na detecção de colangiopatia esquistossomótica. MATERIAIS E MÉTODOS: Estudo prospectivo e transversal em 24 pacientes com a forma hepatoesplênica da esquistossomose mansoni e em 6 pacientes sadios, como grupo controle, com avaliação da via biliar pela CPRM. As alterações (mais) da via biliar consideradas foram: distorção, afilamento, estenose, dilatação e irregularidade. Foi calculada a concordância interobsevador para alteração da via biliar com o teste de McNemar e o índice kappa (κ). RESULTADOS: A concordância interobservador na caracterização de distorção e afilamento da via biliar foi quase perfeita (κ = 0,867; intervalo de confiança [IC] 95% [0,512-1,0] e κ = 0,865; IC 95% [0,51-1,0], respectivamente). A concordância foi substancial para a estenose (κ = 0,78; IC 95% [0,424-1,0]), moderada para dilatação (κ = 0,595; IC 95% [0,247-0,942]) e regular para afilamento (κ = 0,229; IC 95% [0,095-0,552]). CONCLUSÃO: As alterações observadas nas vias biliares foram, em ordem decrescente de ocorrência: distorção, afilamento, estenose, dilatação e irregularidade. A concordância interobservador para sinais de colangiopatia esquistossomótica foi quase perfeita para distorção e afilamento e substancial para estenose. Resumo em inglês OBJECTIVE: To describe changes of the biliary tree demonstrated by magnetic resonance cholangiography (MRC) in patients with the hepatosplenic presentation of schistosomiasis mansoni, and evaluating the interobserver agreement in the detection of schistosomal cholangiopathy. MATERIALS AND METHODS: Prospective, cross-sectional study involving 24 patients with hepatosplenic schistosomiasis and 6 healthy patients (control group) submitted to biliary tree evaluation by MRC. T (mais) he following changes of the biliary tree were considered: distortion, thinning, stenosis, dilation and irregularity. The interobserver agreement in the detection of biliary tree changes was calculated with the McNemar's test and the kappa index of agreement (κ). RESULTS: The interobserver agreement in the detection of distortion and thinning of the biliary tree was almost perfect (κ = 0.867; confidence interval [CI] 95% [0.512-1.0] and κ = 0.865; CI 95% [0.51-1.0], respectively). There was a substantial agreement for stenosis (κ = 0.78; CI 95% [0.424-1.0]), moderate agreement for dilation (κ = 0.595; CI 95% [0.247-0.942]) and mild agreement for thinning (κ = 0.229; CI 95% [0.095-0.552]). CONCLUSION: In a decreasing order of frequency, the changes of the biliary tree were observed: distortion, thinning, stenosis, dilation and irregularity. The interobserver agreement for signs of schistosomal cholangiopathy was almost perfect for distortion and thinning, and substantial for stenosis.

Scientific Electronic Library Online (Portuguese)

47

Correlação entre os achados ultra-sonográficos e de ressonância magnética no teratoma sacrococcígeo fetal/ Correlation between ultrasonographic and magnetic resonance imaging findings in fetal sacrococcygeal teratoma

Antunes, Erika; Werner Jr., Heron; Daltro, Pedro Augusto; Rodrigues, Leise; Amim, Bruno; Guerra, Fernando; Domingues, Romeu Côrtes; Gasparetto, Emerson Leandro
2008-06-01

Resumo em português OBJETIVO: Correlacionar os achados ultra-sonográficos e de ressonância magnética no teratoma sacrococcígeo fetal. MATERIAIS E MÉTODOS: Três pacientes com idade gestacional entre 30 e 35 semanas, com diagnóstico ultra-sonográfico suspeito de teratoma sacrococcígeo fetal, foram submetidas a ressonância magnética e, posteriormente, a ultra-sonografia para correlação dos achados. Tanto na ressonância magnética quanto na ultra-sonografia foram avaliadas as dimen (mais) sões, a localização, a extensão e os conteúdos dos tumores. RESULTADOS: A ultra-sonografia e a ressonância magnética obtiveram resultados semelhantes em relação à localização, ao tamanho e ao conteúdo dos tumores. Todas as lesões localizavam-se na região sacrococcígea, com dimensões médias de 6,0 cm x 9,0 cm. Quanto ao conteúdo dos tumores, um dos casos era completamente cístico e dois eram sólidos e císticos. A extensão exata das lesões foi mais bem avaliada pela ressonância magnética do que pela ultra-sonografia, mostrando de forma adequada o acometimento pélvico nos três casos. CONCLUSÃO: A ressonância magnética fetal é capaz de complementar os achados ultra-sonográficos do teratoma sacrococcígeo fetal, uma vez que determina com melhor precisão o conteúdo e a extensão do tumor, auxiliando na conduta terapêutica e aumentando as chances de cura desses fetos. Resumo em inglês OBJECTIVE: The present study was aimed at correlating ultrasonographic and magnetic resonance imaging findings in patients with fetal sacrococcygeal teratoma. MATERIALS AND METHODS: Three pregnant women between the 30th and 35th weeks of gestation were submitted to fetal magnetic resonance imaging because of previous ultrasonographic findings suggestive of fetal sacrococcygeal teratoma. Subsequently, they were submitted to ultrasonography for correlation of the imaging fi (mais) ndings. Tumors size, location, extent and content were evaluated both at magnetic resonance imaging and ultrasonography. RESULTS: Findings regarding tumor location, size and content were similar for both methods. All the lesions were found in the sacrococcygeal region, with a mean size of 6.0 cm x 9.0 cm. As regards the tumors content, two of them were mixed solid-cystic, and one, entirely cystic. Magnetic resonance imaging was superior to ultrasonography in the evaluation of the exact tumor extent, accurately demonstrating pelvic involvement in all of the three cases. CONCLUSION: Fetal magnetic resonance imaging has showed to be a valuable adjunct to obstetric sonography in the evaluation of fetal sacrococcygeal teratoma, because of its higher accuracy in the determination of these tumors extent and content, playing a significant role in the therapeutic planning and increasing the chances of cure for these fetuses.

Scientific Electronic Library Online (Portuguese)

48

Correlação entre os achados clínicos e imaginológicos nas disfunções temporomandibulares/ Correlation between clinical and imaging findings in patients with temporomandibular disorders

Cozzolino, Fábio Augusto; Rapoport, Abrão; Franzi, Sérgio Altino; Souza, Ricardo Pires de; Pereira, Clemente Augusto de Brito; Dedivitis, Rogério Aparecido
2008-02-01

Resumo em português OBJETIVO: Verificar a relação entre sinais e sintomas observados no exame clínico de pacientes com diagnóstico de disfunção temporomandibular, conforme os resultados fornecidos pelo exame de ressonância magnética. MATERIAIS E MÉTODOS: Trinta pacientes que apresentavam sinais e sintomas de disfunção temporomandibular foram submetidos a exame clínico e de ressonância magnética. Cada exame de ressonância magnética de articulação temporomandibular foi interp (mais) retado, independentemente, por dois radiologistas experientes. Os exames de ressonância magnética foram realizados com 12 cortes de 3 mm de espessura, em orientação coronal (T1) em posição de boca fechada, cortes sagitais em posição de boca aberta e fechada (T1 e T2) e em abertura e fechamento progressivos, com intervalo de 5 mm, para reproduzir toda a extensão do movimento mandibular. A significância estatística entre a análise clínica dos pacientes com disfunção temporomandibular e os resultados obtidos no exame de ressonância magnética foi avaliada pelo teste kappa. RESULTADOS: Obteve-se, na análise interobservadores de imagens, concordância bruta do lado esquerdo e direito, respectivamente, de 56,7% (kappa = 0,1) e 56,7 (kappa = 0). CONCLUSÃO: Não foi encontrada correlação entre o diagnóstico clínico da luxação discal e imagens de ressonância magnética. Resumo em inglês OBJECTIVE: To correlate the signals and symptoms observed on clinical examination of patients with temporomandibular disorder with the results demonstrated by magnetic resonance imaging. MATERIALS AND METHODS: Thirty patients presenting with signs and symptoms of temporomandibular disorders underwent clinical evaluation and subsequent magnetic resonance imaging. The magnetic resonance imaging studies were independently evaluated by two experienced radiologists. Magnetic r (mais) esonance imaging studies consisted of 12 images in coronal, T1-weighted sequences with 3 mm-thick slices with the mouth closed, sagittal, T1- and T2-weighted sequences with both open and closed mouth positions, and on progressive opening/closing movement at 5 mm intervals, in order to demonstrate the full mandibular movement. The statistical significance between the clinical findings in the evaluation of the patients and results found on the magnetic resonance imaging studies was analyzed by means the kappa test. RESULTS: Interobserver agreement was respectively 56.7% (kappa = 0.1) and 56.7 (kappa = 0) for the left and right sides. CONCLUSION: No correlation was found between the clinical and magnetic resonance imaging findings in the diagnoses of disc displacement.

Scientific Electronic Library Online (Portuguese)

49

Correlação entre espessura cortical frontal e desempenho de funções executivas em pacientes com infecção pelo vírus da imunodeficiência humana/ Correlation between frontal cortical thickness and executive functions performance in patients with human immunodeficiency virus infection

Netto, Tania Maria; Greca, Denise Vieira; Ferracini, Rafael; Pereira, Denis B.; Bizzo, Bernardo; Doring, Thomas; Kubo, Tadeu; Bahia, Paulo R. V.; Fonseca, Rochele Paz; Gasparetto, Emerson L.
2011-02-01

Resumo em português OBJETIVO: Investigar a relação entre a espessura cortical medida pela ressonância magnética em regiões frontais e o desempenho em instrumentos que avaliam funções executivas em pacientes com HIV positivo. MATERIAIS E MÉTODOS: Participaram deste estudo 22 pacientes HIV-positivos, com déficits em funções executivas, sob terapia antirretroviral, idades entre 45 e 65 anos e escolaridade entre 3 e 20 anos. Foi realizada ressonância magnética com sequências conven (mais) cionais, T1 3D, processado pelo Freesurfer para verificar espessura cortical. Instrumentos de avaliação das funções executivas: Teste de Trilhas, Wisconsin, Hayling, Dígitos (WAIS-III), fluência verbal ortográfica e Stroop. Para análise da relação espessura versus cognição, utilizou-se coeficiente de correlação de Pearson. RESULTADOS: Correlações significativas foram encontradas entre escores de: Wisconsin e espessura das regiões pré-central e orbitofrontal lateral à direita e pré-central esquerda; Teste de Trilhas e espessura da área pré-central direita e cíngulo anterior caudal esquerdo; e Teste Hayling e espessura da área lateral orbitofrontal esquerda. CONCLUSÃO: As correlações existentes entre medidas de espessura cortical pela ressonância magnética e desempenho cognitivo sugerem que os déficits executivos em pacientes HIV-positivos relacionam-se a uma redução da espessura cortical das regiões frontais. Resumo em inglês OBJECTIVE: To investigate the correlation between frontal regions cortical thickness measured by magnetic resonance imaging of HIV-positive patients and their performance on instruments for assessing executive functions. MATERIALS AND METHODS: The present study included 22 HIV-positive patients in the age range from 45 to 65, schooling ranging between three and 20 years, with executive functions deficit and undergoing antiretroviral therapy. Magnetic resonance imaging was (mais) performed with conventional T1-weighted, 3D sequences and the images were processed with the Freesurfer software to measure cortical thickness. The following instruments were utilized to evaluate the patients' executive functions: Trail Making, Wisconsin, Hayling, working memory (WAIS-III), verbal fluency and Stroop tests. The Pearson's correlation coefficient was utilized in the data statistical analysis. RESULTS: Significant correlations were found between: Wisconsin scores and the thickness of the right pre-central, lateral and left pre-central orbitofrontal regions; Trail Making scores and thickness of right pre-central and left anterior caudal cingulate areas; and Hayling Test scores and thickness of the left lateral orbitofrontal area. CONCLUSION: Correlations between cortical thickness measurements by magnetic resonance imaging and cognitive performance suggest that the executive function deficit in HIV-positive patients are related to a reduction in the thickness of the frontal cortex.

Scientific Electronic Library Online (Portuguese)

50

Confiabilidade da análise qualitativa da ressonância magnética do encéfalo em prematuros extremos/ Reliability of qualitative assessment of brain magnetic resonance imaging in extremely premature infants

Furtado, Andre Dietz; Pinto, Marcus Vinicius Rocha; Rangel, Cláudio de Carvalho; Cruz Jr, Luiz Celso Hygino da; Lopes, José Maria A; Carvalho, Manoel de; Cabral, Jofre Antônio Oliveira; Domingues, Romeu Côrtes; Gasparetto, Emerson Leandro
2010-12-01

Resumo em português OBJETIVO: O objetivo deste estudo foi avaliar a confiabilidade da análise visual qualitativa dos achados de imagem de ressonância magnética (RM) em recém-nascidos prematuros extremos. MATERIAIS E MÉTODOS: Uma coorte de 45 recém-nascidos de idade gestacional de 30 semanas ou menos foram inseridos neste estudo. Dois neurorradiologistas, cegos quanto aos dados clínicos, avaliaram de forma independente as RMs de crânio em relação aos seguintes achados: presença de (mais) hipersinal difuso e excessivo (DEHSI), dilatação dos ventrículos laterais, hemorragia intracraniana, áreas de sinal anormal em núcleos da base e córtex, áreas de aspecto cístico, deformidades ventriculares, dilatação do espaço subaracnóideo, leucoencefalomalácia precoce e anormalidades corticais. RESULTADOS: Quarenta e um pacientes (91,1%) apresentaram exame de RM anormal. Os achados mais comuns foram DEHSI (75,6%) e dilatação dos ventrículos (42,2%). A concordância interobservadores entre os dois experientes neurorradiologistas foi alta (κ > 0,60) para a maioria das alterações detectadas pela RM. O valor de kappa foi moderado (κ = 0,52) para alargamento do espaço subaracnoide e fraco (κ = 0,39) para DEHSI na substância branca. CONCLUSÃO: A avaliação qualitativa da maioria dos achados de imagem por RM de neonatos prematuros extremos foi considerada confiável, entretanto, a presença de DEHSI na substância branca demonstrou um grau de confiabilidade menor Resumo em inglês OBJECTIVE: The present study was aimed at evaluating the reliability of the qualitative visual assessment of brain abnormalities using conventional brain MRI in extremely preterm infants. MATERIALS AND METHODS: A cohort of 45 consecutive infants with gestational age of 30 weeks or less (median of 27 weeks, ranging from 25 to 30 weeks) was enrolled in this study. Two independent, experienced neuroradiologists blindly reviewed MRI studies of the infants' brain for diffuse a (mais) nd excessive high-signal intensity (DEHSI), dilated lateral ventricles, intracranial hemorrhage, areas of abnormal signal in the basal ganglia and cortex, cyst-like areas, ventricular deformities, enlargement of subarachnoid spaces, early leukoencephalomalacia, and cortical abnormalities. RESULTS: Forty-one patients (91.1%) presented abnormalities at MRI. The most common findings were DEHSI in the white matter (75.6%) and ventricular dilatation (42.2%). The interobserver agreement was high (κ > 0.60) for most of the abnormal MRI findings. The kappa statistic values were moderate for enlargement of the subarachnoid space (κ = 0.52) and was only low for DEHSI in the white matter (κ = 0.39). CONCLUSION: Conventional MRI seems to be a reliable method for evaluating the most common brain abnormalities in extremely premature infants; however, the presence of DEHSI in the white matter demonstrated to be is a less reliable finding

Scientific Electronic Library Online (Portuguese)

51

Compósitos de ferrita de Ni-Zn com policloropreno para utilização como materiais absorvedores de radar para a banda S/ S-band radar absorbing materials based on Ni-Zn ferrite and polycloroprene composites

Paulo, E. G.; Pinho, M. S.; Lima, R. da C.; Gregori, M. L.; Ogasawara, T.
2004-06-01

Resumo em português O objetivo deste trabalho foi a obtenção de Materiais Absorvedores de Radar (RAMs) para a faixa de freqüência de 2,6 a 4,0 GHz (banda S). A carga magnética adicionada na proporção de 80% em peso à matriz de policloropreno consistiu de uma ferrita de Ni-Zn. O compósito, com espessura de 6 mm, apresentou um bom desempenho como RAM para toda a faixa de freqüência analisada com absorção de microondas superior a 96,9% (-15 dB) e com absorção máxima de 99,5% (-2 (mais) 5 dB) em 3,2 GHz, viabilizando sua aplicação como revestimento externo em plataformas militares, segundo o ensaio de névoa salina. Resumo em inglês The aim of this work was to obtain Radar Absorbing Materials (RAMs) for the frequency range from 2.6 to 4.0 GHz (S-band). The 80 wt.% magnetic filler addition to a polychloroprene matrix was a Ni-Zn ferrite. The composite with 6 mm thickness showed a good RAM performance for the whole range of frequency analyzed, with a microwave absorption greater than 96.9% (-15 dB), emphasizing the greatest absorption of 99.5% (- 25 dB) at 3.2 GHz, allowing its use as an external coating for naval applications, in accordance with the salt spray testing.

Scientific Electronic Library Online (Portuguese)

52

Carcinoma de seio maxilar: análise de dez casos/ Maxillary sinus carcinoma: an analysis of ten cases

Souza, Ricardo Pires de; Cordeiro, Flamarion de Barros; Gonzalez, Fábio Mota; Yamashiro, Ilka; Paes Junior, Ademar José de Oliveira; Tornin, Olger de Souza; Botelho, Renato Assayag; Leite, Claudia da Costa; Barros, Cristiano Ventorim de; Aquino, Igor Motta de; Macedo, Leonardo Lopes de
2006-12-01

Resumo em português OBJETIVO: Avaliar o papel, principalmente da tomografia computadorizada, no estadiamento dos carcinomas dos seios maxilares. MATERIAIS E MÉTODOS: Foram analisados dez casos de carcinoma diagnosticados e tratados pelos Departamentos de Diagnóstico por Imagem e Cirurgia de Cabeça e Pescoço do Hospital Heliópolis, São Paulo, SP, entre 1988 e 2002. RESULTADOS: Nove pacientes tiveram extensão tumoral para a bochecha, oito para o espaço mastigador, sete para o assoalho (mais) da boca e palato duro, cinco para a fossa pterigóide, cinco para a órbita, três para o etmóide e um para a base do crânio. Três pacientes foram classificados como T3 e sete, como T4. Dois tinham metástases linfonodais no momento da apresentação inicial, os quais pertenciam ao estágio T4. Todos os casos foram confirmados com exame histopatológico. CONCLUSÃO: A análise precisa da extensão local e disseminação tumoral fornecida pela tomografia computadorizada e ressonância magnética desempenha papel importante no planejamento cirúrgico, influenciando, também, na conduta terapêutica e prognóstico. Resumo em inglês OBJECTIVE: To evaluate the role, especially of computed tomography, in the staging of maxillary sinus carcinomas. MATERIALS AND METHODS: Ten cases of carcinoma treated in Hospital Heliópolis Department of Diagnostic Imaging and Head and Neck Surgery, São Paulo, SP, Brazil, in the period between 1988 and 2002, were evaluated. RESULTS: Nine patients presented with tumor extension to the cheek, eight to the masticator space, seven to the mouth floor and hard palate, five t (mais) o the pterygoid fossa, five to the orbit, three to the ethmoid bone, and one to the skull base. Three of the patients were staged T3, and seven T4. Two patients had lymph nodes metastases at their initial presentation, and were staged T4. All of the cases were histopathologically confirmed. CONCLUSION: The accurate analysis of the tumor local extent and dissemination by means of computed tomography and magnetic resonance imaging plays a relevant role in the surgical planning, besides influencing the therapeutic conduct and prognosis.

Scientific Electronic Library Online (Portuguese)

53

Caracterização de cinza do bagaço de cana-de-açúcar para emprego como pozolana em materiais cimentícios/ Characterization of sugar cane bagasse ash for use as pozzolan in cementitious materials

Cordeiro, Guilherme Chagas; Toledo Filho, Romildo Dias; Fairbairn, Eduardo de Moraes Rego
2009-01-01

Resumo em inglês This work presents the results of morphological and physical-chemical characteristics of a sugar cane bagasse ash material sample produced under controlled burning conditions. The investigation was carried out by analyzing chemical composition, X-ray diffraction, 29Si nuclear magnetic resonance, morphology, thermal analysis, particle size, specific surface, and density. Moreover, the pozzolanic activity of the ash was evaluated by pozzolanic activity index and Chapelle's (mais) method. The results suggest that the sugar cane bagasse ash has adequate properties to be used as pozzolan in construction materials.

Scientific Electronic Library Online (Portuguese)

54

Caracterização de argilas encontradas em solos de Terras Indígenas do RS com o auxílio da espectroscopia Mössbauer de 57Fe/ Characterization of clays found in soils of the Indian Territories in Rio Grande do Sul State by using the 57Fe Mössbauer spectroscopy

Pérez, C. A. S.; Gobbi, D.; Marcos, J. L. N.; Paduani, C.; Ardisson, J. D.
2004-06-01

Resumo em português As argilas encontradas em amostras de solos, provenientes de Terras Indígenas do planalto médio do Rio Grande do Sul, foram caracterizadas com o intuito de fornecer dados e parâmetros técnicos para seu uso como matéria prima de produtos cerâmicos. O estudo mineralógico efetuado nas amostras utilizando a técnica de difração de raios X demonstrou que o argilomineral predominante é a caulinita. Outros minerais, como quartzo e rutilo, encontram-se presentes em meno (mais) r quantidade. As análises químicas demonstram que as quantidades de óxido de Mg, Mn, K, Na, Ca, Cu e Zn são baixas (a soma das porcentagens é menor que 0,97 %). As amostras foram analisadas por espectroscopia Mössbauer de 57Fe. Os espectros Mössbauer obtidos na temperatura ambiente confirmam a presença do mineral caulinita. Os espectros a 77 K revelam a existência dos minerais goetita e hematita, na forma de partículas magnéticas ultrafinas (nanopartículas) em estado superparamagnético. Os testes físicos efetuados nas amostras indicam que os solos são finos e apresentam características granulométricas e de plasticidade, que podem ser aproveitadas para a produção de materiais cerâmicos para construção ou objetos ornamentais. Resumo em inglês Clay samples collected from soils of indian territories of the middle plateau in Rio Grande do Sul were analyzed with the aim to obtain characterization data and technical parameters for their potential use as raw material for ceramic products. The mineralogical study in samples by using the X-ray diffraction technique demonstrated that the predominant clay mineral is kaolinite. Others minerals as quartz and rutile also are present in small amounts. Chemical analysis show (mais) s low percentages for oxides of Mg, Mn, K, Na, Ca, Cu and Zn (overall percentages smaller than 0.97%). The samples also were analyzed with the 57Fe Mössbauer spectroscopy. The Mössbauer spectra at room temperature confirm the presence of the mineral kaolinite. At 77 K they reveal the existence of the minerals goethite and hematite as ultrafine magnetic particles in a superparamagnetic state. The physical tests performed in the samples show that these soils are very fine material and present appropriate granulometric characteristics and plasticity, which can be taken in advantage for the production of materials for construction or production of ornamental artifacts.

Scientific Electronic Library Online (Portuguese)

55

Capacidade de produção de grãos e óleo em linhagens e cultivares de amendoim/ Grain and oil yield capability of peanut lines and cultivars

Godoy, Ignácio José de; Pereira, José Carlos Vila Nova Alves; Martins, Antonio Lucio Mello
1989-01-01

Resumo em português Avaliaram-se doze linhagens de amendoim pertencentes à coleção de germoplasma do Instituto Agronômico e os cultivares Tatuí e Tatu, este usado como controle, quanto ao teor de óleo e à produtividade de grãos e de óleo em experimentos conduzidos durante o plantio das águas de 1983/84, 1984/85 e 1985/86 no Centro Experimental de Campinas; de 1983/84 e 1985/86 na Estação Experimental de Pindorama, e de 1985/86 na Estação Experimental de Ribeirão Preto. A maior (mais) ia do material incluído nas avaliações apresentou, no mínimo, o mesmo nível de produtividade do controle, cv. Tatu - 2.154kg/ha - constituindo material promissor para inclusão nos trabalhos de melhoramento. Destacaram-se em produtividade de grãos e de óleo as linhagens 5567 e Ca-34 e o cv. Tatuí. A 269 apresentou o maior teor de óleo nas sementes, 50,5%, contra 47,2% do controle. Os resultados obtidos mostraram casos em que o teor de óleo nas sementes influenciou o desempenho relativo do material em termos de produção de óleo por área. Isso indica que o teor de óleo deve ser levado em consideração, pelo menos quando da escolha dos pais para os cruzamentos ou nas últimas fases de seleção das linhagens. Resumo em inglês Twelve peanut lines and the cultivars Tatuí and Tatu were evaluated for grain and oil yield, and seed oil content. The experiments were conducted during the spring summer growing seasons of 1983, 1984 and 1985 at Campinas, 1983 and 1984 at Pindorama and 1985 at Ribeirão Preto Experimental Stations, Instituto Agronômico, State of São Paulo, Brazil. Oil content was determined by the nuclear magnetic resonance (NMR) method. Oil yield was calculated from the grain yield a (mais) nd seed oil content. Most of the treatments yielded as much as the control, cv. Tatu. This indicates that they can be considered as promising materials for breeding programs. The highest grain, and oil yields were obtained with lines 5567, Ca-34 and cv. Tatuí. The highest seed oil content, 50.5%, was observed for line 269, in contrast with 47.2% of the control. The results also showed that the seed oil content affected the relative performance of a line in terms of oil yield. Thus, there are evidences that the seed oil content must be evaluated when choosing parents for crossing or in the final stages of line selection.

Scientific Electronic Library Online (Portuguese)

56

Avaliação ultra-sonográfica de nódulos sideróticos esplênicos em pacientes esquistossomóticos com hipertensão portal/ Ultrasonographic assessment of splenic siderotic nodules in schistosomal patients with portal hypertension

Gonzalez, Thais Dias; Santos, José Eduardo Mourão; Sales, Danilo Moulin; Takemoto, Kenji; Capobianco, Júlia; Brant, Paulo Eugênio; Colleoni, Ramiro; Ahmed, Munneb; D'Ippolito, Giuseppe
2008-04-01

Resumo em português OBJETIVO: Medir a sensibilidade e a reprodutibilidade da ultra-sonografia na detecção de nódulos sideróticos esplênicos em pacientes esquistossomóticos, tendo a ressonância magnética como padrão de referência. MATERIAIS E MÉTODOS: Na primeira fase do trabalho, 21 pacientes portadores de esquistossomose na forma hepatoesplênica com diagnóstico de nódulos sideróticos à ressonância magnética foram submetidos a avaliação ultra-sonográfica para a determina (mais) ção da sensibilidade do método. Na segunda fase, com o objetivo de avaliar a reprodutibilidade da ultra-sonografia na detecção e na quantificação de nódulos sideróticos (A: 1-5 nódulos; B: 6-20 nódulos; C: mais de 20 nódulos), outros 30 pacientes esquistossomóticos foram submetidos a avaliação ultra-sonográfica de forma cega e independente por dois observadores. A reprodutibilidade foi medida por meio da concordância entre os observadores e do teste kappa. RESULTADOS: A sensibilidade da ultra-sonografia foi de 95,2% (intervalo de confiança a 95% [77,3%; 99,2%]). A concordância entre ultra-sonografia e ressonância magnética para a detecção de nódulos sideróticos foi de 96,7% (intervalo de confiança a 95% [82,8%; 99,9%]). Para a classificação dos nódulos conforme a sua quantificação, o índice kappa demonstrou concordância interobservador substancial (kappa = 0,67). CONCLUSÃO: A ultra-sonografia é um método que apresenta elevada sensibilidade e boa precisão para a avaliação de nódulos sideróticos esplênicos. Resumo em inglês OBJECTIVE: To evaluate ultrasound sensitivity and reproducibility as compared with magnetic resonance imaging as the gold standard in the detection of splenic siderotic nodules in schistosomal patients. MATERIALS AND METHODS: Initially, 21 patients with hepatosplenic schistosomiasis and diagnosed with splenic siderotic nodules by magnetic resonance imaging were ultrasonographically evaluated for determining the method sensitivity. In a second phase, the method reproducibi (mais) lity in the detection and quantification of siderotic nodules (A: 1-5 nodules; B: 6-20 nodules; C: > 20 nodules) was evaluated in 30 patients who were submitted to ultrasonography blindly and independently assessed by two observers. Interobserver agreement was measured by kappa statistics. RESULTS: Ultrasound sensitivity was 95.2% (95% confidence interval [77.3%; 99.2%]). Intermethod agreement in the detection of siderotic nodules was 96.7% (95% confidence interval [82.8%; 99.9%]). For classification of nodules according to their quantification, the kappa test demonstrated a statistically significant interobserver agreement (kappa = 0.67). CONCLUSION: Ultrasonography is highly sensitive and accurate in the assessment of splenic siderotic nodules in schistosomal patients.

Scientific Electronic Library Online (Portuguese)

57

Avaliação textural por ressonância magnética dos tumores da fossa posterior em crianças/ Magnetic resonance imaging textural evaluation of posterior cranial fossa tumors in childhood

Santos, Joelson Alves dos; Costa, Maria Olívia Rodrigues da; Otaduy, Maria Concepcion Garcia; Lacerda, Maria Teresa Carvalho de; Matsushita, Hamilton; Leite, Claudia da Costa
2004-08-01

Resumo em português OBJETIVO: Possibilitar a distinção entre tecidos sãos e patológicos em pacientes da faixa etária pediátrica portadores de tumores da fossa posterior, por meio da análise de parâmetros texturais calculados a partir de imagens de ressonância magnética. MATERIAIS E MÉTODOS: Foram analisados 14 pacientes da faixa etária pediátrica, portadores de tumores da fossa posterior, através da definição dos valores texturais das regiões de interesse representando tecid (mais) os sãos e patológicos, com base em imagens de ressonância magnética pesadas em T2 pelo "software" MaZda. RESULTADOS: Houve diferença estatisticamente significativa entre os tecidos normal e tumoral, bem como entre os tecidos presumidamente normais adjacentes e distantes da lesão. Não foi possível a distinção entre edema e tumor. CONCLUSÃO: A avaliação textural por ressonância magnética é uma técnica útil para a determinação de diferenças entre diversos tipos de tecidos, inclusive entre áreas de tecidos presumidamente normais à análise visual. Resumo em inglês OBJECTIVE: To distinguish healthy from pathological tissues in pediatric patients with posterior cranial fossa tumors using calculated textural parameters from magnetic resonance images. MATERIALS AND METHODS: We evaluated 14 pediatric patients with posterior cranial fossa tumors using the software MaZda to define the texture parameters in selected regions of interest representing healthy and pathological tissues based on T2-weighted magnetic resonance images. RESULTS: Th (mais) ere was a statistically significant difference between normal and tumoral tissues as well as between supposedly normal tissues adjacent and distant from the tumoral lesion. CONCLUSION: Magnetic resonance textural evaluation is an useful tool for determining differences among various tissues, including tissues that appear apparently normal on visual analysis.

Scientific Electronic Library Online (Portuguese)

58

Avaliação quantitativa das forças laterais da patela: ressonância magnética estática e cinemática/ Quantitative evaluation of lateral forces on the patella: static and kinematic magnetic resonance imaging

Yang, Je Hoon; Demarchi, Guilherme Tadeu Sauaia; Garms, Emerson; Juliano, Yara; Mestriner, Luiz Aurélio; Cohen, Moises; Navarro, Ricardo Dizioli; Fernandes, Artur da Rocha Corrêa
2007-08-01

Resumo em português OBJETIVO: Avaliar a validade da ressonância magnética cinemática combinada com a ressonância magnética estática no estudo da articulação femoropatelar. MATERIAIS E MÉTODOS: Foram realizadas ressonância magnética estática e ressonância magnética cinemática em 20 voluntários assintomáticos (40 joelhos) e em 23 pacientes (43 joelhos), em aparelho de configuração fechada de 1,5 tesla de campo. Os indivíduos foram posicionados na extremidade da mesa, em 30& (mais) deg; de flexão. A translação patelar foi avaliada medindo-se o desvio da bissetriz, o deslocamento lateral da patela e o ângulo de inclinação da patela. Para a comparação entre os estudos estático e cinemático, foi utilizado o teste não-paramétrico de Wilcoxon. Para a comparação entre os voluntários e os pacientes, foi utilizado o teste de Mann-Whitney. RESULTADOS: Houve diferenças significantes entre a ressonância magnética estática e a ressonância magnética cinemática (p Resumo em inglês OBJECTIVE: To evaluate the usefulness of combining static and kinematic magnetic resonance imaging in the evaluation of the femoropatellar joint. MATERIALS AND METHODS: Twenty healthy volunteers (40 knees) and 23 patients (43 knees) were submitted to both static and kinematic magnetic resonance imaging on a 1.5 tesla whole-body magnetic resonance scanner. The knees were positioned at 30º flexion with the quadrature knee coil at the inner end of the examination table. The (mais) patellar translation was evaluated by measurements of bisect offset, lateral patellar displacement and patellar tilt angle. The nonparametric Wilcoxon test was utilized for statistical analysis of data resulting from the static and kinematic studies in both groups. Nonparametric Mann-Whitney test was utilized in the comparison between healthy volunteers and patients. RESULTS: Statistical analysis demonstrated significant differences (p

Scientific Electronic Library Online (Portuguese)

59

Avaliação hepática e esplênica por ressonância magnética em pacientes portadores de esquistossomose mansônica crônica/ Liver and spleen magnetic resonance imaging evaluation in patients with chronic Schistosoma mansoni infection

Bezerra, Alexandre Sérgio de Araújo; D'Ippolito, Giuseppe; Caldana, Rogério Pedreschi; Cecin, Alexandre Oliveira; Szejnfeld, Jacob
2004-10-01

Resumo em português OBJETIVO: Avaliar, qualitativa e quantitativamente, as alterações morfológicas hepáticas e esplênicas por ressonância magnética (RM) em pacientes portadores de esquistossomose mansônica crônica, e a reprodutibilidade do método na avaliação hepatoesplênica destes pacientes. MATERIAIS E MÉTODOS: Realizou-se estudo prospectivo em 28 pacientes esquistossomóticos submetidos à RM de abdome superior. Os exames foram realizados em equipamento com alto campo (1,5 T (mais) ), utilizando-se bobina de corpo e bomba injetora para a administração do contraste endovenoso, e interpretados por dois examinadores independentes, que avaliaram a presença de alterações morfológicas hepáticas e esplênicas. A concordância interobservador e intra-observador foram medidas pelo teste kappa e pelo teste do coeficiente de correlação intraclasses. RESULTADOS: As variáveis qualitativas e quantitativas apresentaram boa concordância interobservador e intra-observador (kapa > 0,65 e r > 0,66, respectivamente). A maior concordância interobservador foi obtida para o diâmetro ântero-posterior do baço (r = 0,98). Os observadores identificaram redução do lobo hepático direito, aumento do lobo hepático esquerdo e caudado associado a esplenomegalia em quase todos os pacientes, e alargamento de fissuras, heterogeneidade do parênquima hepático, irregularidade de contornos, vasos periféricos hepáticos e fibrose periportal em mais de 82% dos pacientes. CONCLUSÃO: As alterações morfológicas hepáticas caracterizam-se pela redução do lobo direito e aumento dos lobos caudado e esquerdo, e as esplênicas, pela presença de esplenomegalia e nódulos sideróticos. A RM apresenta elevada reprodutibilidade na avaliação dessas alterações em pacientes com esquistossomose mansônica crônica. Resumo em inglês OBJECTIVE: To qualitatively and quantitatively evaluate the morphological changes of the liver and spleen using magnetic resonance imaging (MRI) in patients with chronic infection by Schistosoma mansoni and the reproducibility of MRI findings in the hepatosplenic evaluation of these patients. MATERIALS AND METHODS: We prospectively studied 28 schistosomotic patients submitted to MRI of the upper abdomen. The scans were performed using a high field equipment (1.5 T), a bod (mais) y coil and a power injector for administration of intravenous contrast. The scans were interpreted by two independent examiners who evaluated the presence of morphological changes in the liver and spleen. Interobserver and intraobserver agreement were measured using the kappa and intraclass correlation tests. RESULTS: Qualitative variables presented good interobserver and intraobserver agreement (kappa > 0.65 and r > 0.66, respectively). The best interobserver agreement was for the anteroposterior diameter of the spleen (r = 0.98). The observers identified reduction of the right hepatic lobe, enlargement of the left hepatic lobe and caudate lobes associated with splenomegaly in almost all patients, and also identified fissure widening, heterogeneity of hepatic parenchyma, irregularity of hepatic contours, presence of peripheral hepatic vessels and periportal fibrosis in almost all patients. CONCLUSION: Hepatic morphological changes are characterized by reduction of the right lobe and enlargement of the caudate and left lobes, and morphological changes in the spleen are characterized by the presence of splenomegaly and siderotic nodules. MRI presents high reproducibility for the evaluation of these changes in patients with chronic infection by Schistosoma mansoni.

Scientific Electronic Library Online (Portuguese)

60

Avaliação do volume de fluxo portal em pacientes esquistossomóticos: estudo comparativo entre ressonância magnética e ultrassom Doppler/ Evaluation of portal blood flow in schistosomal patients: a comparative study between magnetic resonance imaging and Doppler ultrasonography

Leão, Alberto Ribeiro de Souza; Sales, Danilo Moulin; Santos, José Eduardo Mourão; Nakano, Edson; Shigueoka, David Carlos; D'Ippolito, Giuseppe
2010-12-01

Resumo em português OBJETIVO: Avaliar a concordância entre o ultrassom Doppler e a ressonância magnética e a reprodutibilidade interobservador desses métodos na quantificação do volume de fluxo portal em indivíduos esquistossomóticos. MATERIAIS E MÉTODOS: Foi realizado estudo transversal, observacional e autopareado, avaliando 21 pacientes portadores de esquistossomose hepatoesplênica submetidos a mensuração do fluxo portal por meio de ressonância magnética (utilizando-se a té (mais) cnica phase-contrast) e ultrassom Doppler. RESULTADOS: Observou-se baixa concordância entre os métodos (coeficiente de correlação intraclasse: 34,5% [IC 95%]). A reprodutibilidade interobservador na avaliação pela ressonância magnética (coeficiente de correlação intraclasse: 99,2% [IC 95%] / coeficiente de correlação de Pearson: 99,2% / média do fluxo portal = 0,806) e pelo ultrassom Doppler (coeficiente de correlação intraclasse: 80,6% a 93,0% [IC 95%] / coeficiente de correlação de Pearson: 81,6% a 92,7% / média do fluxo portal = 0,954, 0,758 e 0,749) foi excelente. CONCLUSÃO: Há uma baixa concordância entre o ultrassom Doppler e a ressonância magnética na mensuração do volume de fluxo na veia porta. A ressonância magnética e o ultrassom Doppler são métodos reprodutíveis na quantificação do fluxo portal em pacientes portadores de hipertensão porta de origem esquistossomótica, apresentando boa concordância interobservador Resumo em inglês OBJECTIVE: To evaluate the agreement between Doppler ultrasonography and magnetic resonance imaging as well as the interobserver reproducibility of both methods in the measurement of portal blood flow in schistosomal patients. MATERIALS AND METHODS: A cross-sectional, observational, self-paired study evaluated 21 patients with schistosomiasis mansoni submitted to measurement of portal blood flow with phase-contrast magnetic resonance imaging and Doppler ultrasonography. R (mais) ESULTS: A poor intermethod agreement was observed (intraclass correlation coefficient: 34.5% [CI 95%]). On the other hand, the interobserver reproducibility was excellent in the evaluation by magnetic resonance imaging (intraclass correlation coefficient: 99.2% [CI 95%] / Pearson's correlation coefficient: 99.2% / portal blood flow = 0.806) and by Doppler ultrasonography (intraclass correlation coefficient: 80.6 to 93.0% [CI 95%] / Pearson's correlation coefficient: 81.6% to 92.7% / portal blood flow = 0.954, 0.758 and 0.749). CONCLUSION: There is a poor intermethod agreement in the measurement of portal blood flow. Nevertheless, contrast-phase magnetic resonance imaging and Doppler ultrasonography demonstrated to be reproducible methods presenting excellent interobserver agreement in the quantification of portal blood flow in patients with hepatosplenic schistosomiasis-related portal hypertension

Scientific Electronic Library Online (Portuguese)

61

Avaliação do desempenho de materiais absorvedores de radiação eletromagnética por guia de ondas/ Performance of radar absorbing materials by waveguide measurements

Pinho, Magali S.; Lima, Roberto C.; Soares, Bluma G.; Nunes, Regina C. R.
1999-12-01

Resumo em português Neste trabalho, amostras elastoméricas contendo diferentes tipos de cargas absorvedoras de microondas, sob a forma de pós, foram obtidas para medidas de refletividade. Os materiais utilizados com diferentes composições percentuais em peso foram: ferrocarbonila, negro de fumo, polianilina e ferrita dopadas. As medidas de refletividade foram determinadas com base nas propriedades magnéticas e dielétricas dos compósitos elastoméricos a partir de dados de espalhamento (mais) , através da inserção e fixação em um guia de ondas, para a faixa de freqüência de 8-16 GHz. Os melhores resultados foram apresentados pelo ferrocarbonila e negro de fumo para as freqüências mais baixas, enquanto a ferrita dopada absorveu em uma freqüência mais elevada. Resumo em inglês In this work, samples consisting of an elastomeric matrix containing different kinds of active material in particulate form were prepared for reflectivity measurements. The materials used in different contents were: carbonyl-iron, carbon black, doped polyaniline and doped ferrite. The microwave reflectivity levels were determined from the magnetic and dielectric properties of the elastomeric composites from scattering data, by fitting the samples in a waveguide, for measu (mais) rements in the frequency range of 8-16 GHz. Better microwave absorption at low frequencies was obtained for carbonyl-iron and carbon black while doped ferrite absorbed at high frequencies.

Scientific Electronic Library Online (Portuguese)

62

Avaliação de meios de contraste submetidos à radiação ionizante/ Evaluation of contrast media submitted to ionizing radiation

Pinho, Kátia Elisa Prus; Gewehr, Pedro Miguel; Silva, Caroline Werner Pereira da; Barison, Andersson; Tilly Júnior, João Gilberto; Soboll, Danyel Scheidegger
2009-10-01

Resumo em português OBJETIVO: O presente estudo consistiu em investigar a influência da radiação ionizante por raios X e raios gama sobre a estabilidade molecular de diversos meios de contraste radiológicos utilizados em exames de diagnóstico por imagem, por meio da espectroscopia de ressonância magnética nuclear de ¹H e 13C. MATERIAIS E MÉTODOS: Oito diferentes meios de contraste iodados (três iônicos e cinco não iônicos) foram expostos à radiação por raios X e raios gama. E (mais) m seguida, espectros de ressonância magnética nuclear de ¹H e 13C{¹H} foram coletados. RESULTADOS: Os espectros de ressonância magnética nuclear de 13C{¹H} de ambos os meios de contraste iônicos e não iônicos irradiados por raios X ou raios gama mostraram que não houve alterações na composição química desses contrastes. CONCLUSÃO: Não há problemas em armazenar as amostras nas salas, ou próximo aos equipamentos em que são realizados os exames. Enfatiza-se que a radiação recebida pelas amostras durante os ensaios foi direta, enquanto em uma sala de exames de radiodiagnóstico a radiação é indireta e, portanto, os níveis de radiações nestes casos são bastante inferiores àqueles empregados neste estudo. Resumo em inglês OBJECTIVE: The purpose of the present study was to investigate the influence of ionizing radiation from x-rays and gamma rays on the molecular structure stability of several radiologic contrast media employed in diagnostic imaging by means of ¹H and 13C nuclear magnetic resonance spectroscopy. MATERIALS AND METHODS: Eight different types of iodinated contrast media (three ionic and five non-ionic) were exposed to x-rays and gamma rays irradiation. Subsequently, the ¹H a (mais) nd 13C{¹H} nuclear magnetic resonance spectra of these contrast media were collected. RESULTS: The ¹H and 13C{¹H} nuclear magnetic resonance spectra of both ionic and non-ionic contrast media irradiated by x-rays or gamma rays demonstrated the absence of any alteration of the contrast media chemical composition. CONCLUSION: There is no problem in keeping contrast media inside examination rooms or close to radiological equipment. It is important to mention that, during the tests, the samples were directly irradiated, while in a radiology examination room, the irradiation is not direct and, therefore, radiation levels in these cases are much lower than those employed in the present study.

Scientific Electronic Library Online (Portuguese)

63

Avaliação de linfangiomas cervicais fetais por ressonância magnética e correlação com achados ultrassonográficos/ Evaluation of fetal cervical lymphangioma by magnetic resonance imaging and correlation with sonographic findings

Antunes, Erika da Gloria; Werner Junior, Heron; Daltro, Pedro Augusto; Rodrigues, Leise; Amim, Bruno; Guerra, Fernando; Domingues, Romeu Côrtes; Gasparetto, Emerson Leandro
2009-10-01

Resumo em português OBJETIVO: Avaliar três casos de linfangioma cervical por ressonância magnética e correlacionar com os achados da ultrassonografia. MATERIAIS E MÉTODOS: Três pacientes com idade gestacional entre 24 e 35 semanas, com suspeita de higromas císticos cervicais fetais na ultrassonografia obstétrica de rotina, foram submetidas a ressonância magnética e, posteriormente, a nova ultrassonografia para correlação dos achados. Em ambos os métodos de imagem foram avaliadas (mais) as dimensões, a localização, o conteúdo e a extensão das lesões. RESULTADOS: Tanto a ultrassonografia quanto a ressonância magnética avaliaram de modo semelhante a localização, o tamanho e o conteúdo dos tumores. As três lesões localizavam-se na região cervical posterior e lateral. Quanto ao conteúdo, duas eram predominantemente císticas com finos septos em seu interior e uma era heterogênea. A extensão e invasão das estruturas adjacentes foram mais bem caracterizadas na ressonância magnética do que na ultrassonografia, demonstrando de forma adequada o acometimento do pavilhão auditivo do feto em um caso e do mediastino superior em outro. CONCLUSÃO: A ressonância magnética fetal pode ser um complemento útil da ultrassonografia em fetos portadores de linfangiomas, avaliando de forma mais precisa a extensão e invasão de estruturas vizinhas, permitindo melhor planejamento cirúrgico pós-natal. Resumo em inglês OBJECTIVE: To evaluate three cases of cervical lymphangioma with magnetic resonance imaging and correlating with sonographic findings. MATERIALS AND METHODS: Three pregnant women between the 24th and 35th gestational weeks, with sonographic findings suggestive of fetal cystic hygroma, were submitted to magnetic resonance and subsequently to a new ultrasonography for correlation of imaging findings. Tumors size, location, content and extent were evaluated both at magnetic (mais) resonance imaging and ultrasonography. RESULTS: Findings regarding tumor location, size and content were similar for both methods. All the lesions were found in the posterior and lateral cervical space. As regards the tumors content, two of the lesions were predominantly cystic, with thin septations, and the other was heterogeneous. Lesions extent and adjacent structures invasion were better characterized by magnetic resonance imaging, with appropriate demonstration of invasion of the pinna in one case and invasion of the superior mediastinum in another. CONCLUSION: Fetal magnetic resonance imaging can be a useful adjuvant to obstetric ultrasonography in cases of lymphangioma because of its higher accuracy in the determination of these tumors extent and adjacent structures invasion, allowing a better postnatal surgical planning.

Scientific Electronic Library Online (Portuguese)

64

Avaliação das fístulas urogenitais por urorressonância magnética/ Evaluation of urogenital fistulas by magnetic resonance urography

Mamere, Augusto Elias; Coelho, Rafael Darahem Souza; Cecin, Alexandre Oliveira; Feltrin, Leonir Terezinha; Lucchesi, Fabiano Rubião; Pinheiro, Marco Antônio Lopes; Borges, Ana Karina Nascimento; Garcia, Gustavo Fabene; Seabra, Daniel
2008-02-01

Resumo em português OBJETIVO: As fístulas vesicovaginais e ureterovaginais são complicações incomuns, secundárias a doenças ou a cirurgias pélvicas. O sucesso terapêutico dessas fístulas depende de adequada avaliação pré-operatória para o diagnóstico e visualização do seu trajeto. Este trabalho tem o objetivo de demonstrar o potencial da urorressonância no diagnóstico das fístulas urogenitais e na visualização dos seus trajetos. MATERIAIS E MÉTODOS: Foram analisados, re (mais) trospectivamente, os prontuários médicos e as imagens radiológicas e de urorressonância magnética de sete pacientes do sexo feminino com diagnóstico de fístula urogenital. Para a urorressonância foram realizadas seqüências 3D-HASTE com saturação de gordura. RESULTADOS: Seis pacientes apresentavam fístula vesicovaginal e uma paciente tinha diagnóstico de fístula ureterovaginal à direita. Com a utilização da urorressonância magnética, foi possível demonstrar o trajeto da fístula em seis das sete pacientes (85,7%), sem a necessidade de cateterização vesical ou da injeção de contraste. CONCLUSÃO: Este estudo demonstra o potencial e a aplicabilidade da urorressonância na avaliação dessas fístulas. Resumo em inglês OBJECTIVE: Vesicovaginal and ureterovaginal fistulas are unusual complications secondary to pelvic surgery or pelvic diseases. The therapeutic success in these cases depends on an appropriate preoperative evaluation for diagnosis and visualization of the fistulous tract. The present study is aimed at demonstrating the potential of magnetic resonance urography for the diagnosis of vesicovaginal and ureterovaginal fistulas as well as for defining the fistulous tracts. MATER (mais) IALS AND METHODS: Seven female patients clinically diagnosed with vesicovaginal or ureterovaginal fistulas had their medical records, radiological and magnetic resonance images retrospectively reviewed. Magnetic resonance urography included 3D-HASTE sequences with fat saturation. RESULTS: Six patients presented vesicovaginal fistulas and, in one patient, a right-sided ureterovaginal fistula was diagnosed. Magnetic resonance urography allowed the demonstration of the fistulous tract in six (85.7%) of the seven patients evaluated in the present study, without the need of bladder catheterization or contrast injection. CONCLUSION: This study demonstrates both the potential and applicability of magnetic resonance urography in the evaluation of these types of fistulas.

Scientific Electronic Library Online (Portuguese)

65

Avaliação da susceptibilidade magnética usando uma balança analítica/ Evaluation of the magnetic susceptibility using an analytical scale

Carneiro, Antonio Adilton O.; Touso, Alessandro Tadeu; Baffa, Oswaldo
2003-12-01

Resumo em inglês A simple system to measure the magnetic susceptibility of different materials is presented. The system uses an analytical scale with sensitivity on the order of micrograms and a permanent NdBFe magnet, based in the Rankine method. In this apparatus, the sample is placed near to the magnet that is fixed on the scale. Depending on the magnetic properties of the sample, an attractive or repulsive force will appear between the magnet and the magnetizing sample. Measuring this (mais) force, registered by the scale as a mass, the magnetic parameters such as: permeability and susceptibility of the sample can be determined. Despite it is simplicity the method is quantitative, precise and easily reproducible in many laboratories, what makes it attractive for teaching experiments.

Scientific Electronic Library Online (Portuguese)

66

Avaliação da função ventricular esquerda pela sequência de ressonância magnética sem apneia e com múltiplas excitações/ Left ventricular function assessment by free-breathing magnetic resonance sequence with multiple excitations

Nakano, Edson Minoru; Shigueoka, David Carlos; Szarf, Gilberto; Pinetti, Rogério Zaia; Santos, José Eduardo Mourão; Szejnfeld, Denis; Barbieri, Antônio
2009-10-01

Resumo em português OBJETIVO: Avaliar a eficácia da sequência de ressonância magnética com três excitações, para obtenção de volumes e massas ventriculares, em indivíduos com respiração livre, sem apneia. MATERIAIS E MÉTODOS: Em 32 voluntários sadios, foram comparados os volumes e massas do ventrículo esquerdo, obtidos por meio de duas sequências de ressonância magnética em modo cine. A primeira, tradicionalmente utilizada e considerada padrão, em apneia e com excitação (mais) única, e a segunda, em respiração livre e com três excitações. Três leitores, com diferentes níveis de experiência, testaram a concordância e a reprodutibilidade. Para a análise estatística foram utilizados o coeficiente de correlação intraclasse, o teste t-pareado, os gráficos de Bland-Altman e o teste do sinal. RESULTADOS: Para os dois observadores mais experientes, os coeficientes de correlação intraclasse foram superiores a 0,913, assim como os níveis descritivos do teste t-pareado acima de 0,05, os gráficos de Bland-Altman com as diferenças distribuídas aleatoriamente em torno do zero e o teste do sinal com seu nível descritivo superior a 0,05. CONCLUSÃO: A sequência testada apresenta ótima concordância e reprodutibilidade em relação à sequência padrão, podendo ser aplicada em indivíduos com limitações respiratórias. Resumo em inglês OBJECTIVE: To evaluate the efficacy of free-breathing magnetic resonance sequence with three excitations in the determination of ventricular volumes and masses in individuals without breathholding. MATERIALS AND METHODS: Left ventricular volumes and masses determined in 32 healthy volunteers through two cine magnetic resonance imaging sequences were compared: the first sequence, traditionally utilized and considered as a standard, performed under apnea, with a single exci (mais) tation, and the second one, with free-breathing and three excitations. Three observers at different levels of experience evaluated the agreement and reproducibility. Intraclass correlation coefficient, paired t-test, Bland-Altman plots and sign test were utilized for statistical analysis. RESULTS: According to the two most experienced observers, intraclass correlation coefficients were > 0.913, the paired t-test demonstrated P values > 0.05, Bland-Altman plots had differences randomly distributed around zero and the sign test descriptive levels were > 0.05. CONCLUSION: The sequence evaluated presents an excellent agreement and reproducibility as compared with the standard sequence, and can be utilized in patients with respiratory limitations.

Scientific Electronic Library Online (Portuguese)

67

Avaliação da função cardíaca por ressonância magnética com seqüências em equilíbrio estável: segmentadas × tempo real/ Assessment of cardiac function by magnetic resonance imaging: segmented x real-time steady-state free precession sequences

Bezerra, Leonardo Bernardo; Marchiori, Edson; Pontes, Paulo V.
2006-10-01

Resumo em português OBJETIVO: Comparar os índices de função sistólica ventricular obtidos entre as seqüências de cine-ressonância magnética em equilíbrio estável, em tempo real e acoplada ao eletrocardiograma, em pacientes com ritmo regular ou não. MATERIAIS E MÉTODOS: Foram comparados a fração de ejeção e os volumes diastólico e sistólico finais, em 31 pacientes, 11 com ritmo cardíaco irregular e 20 com ritmo cardíaco sinusal regular, utilizando-se seqüências segmentad (mais) as acopladas ao eletrocardiograma e em tempo real. O tratamento estatístico foi feito através da correlação de Pearson e a concordância de Bland-Altman, com p Resumo em inglês OBJECTIVE: To compare ventricular systolic parameters on segmented and real-time steady-state free precession cine-MRI sequences and ECG-gated MRI in patients presenting or not with cardiac arrhythmias. MATERIALS AND METHODS: Ejection fraction and end-diastolic/end-systolic volumes have been compared in 31 patients, 11 presenting with cardiac arrhythmias, and 20 with regular sinus rhythm, using ECG-gated segmented and real-time sequences. The statistical analysis was perf (mais) ormed using Pearson's correlation and Bland-Altman agreement plot, with p

Scientific Electronic Library Online (Portuguese)

68

Avaliação da doença de Parkinson pela ressonância magnética/ Evaluation of Parkinson´s disease using magnetic resonance imaging

Vedolin, Leonardo; Marchiori, Edson; Rieder, Carlos
2004-04-01

Resumo em português OBJETIVO: Avaliar a doença de Parkinson pela ressonância magnética. MATERIAIS E MÉTODOS: De outubro de 1999 a outubro de 2002, foram estudados 42 pacientes com parkinsonismo, por meio de um aparelho de ressonância magnética de 1,5 T. Os pacientes foram divididos em dois grupos: grupo com doença de Parkinson (n = 26) e grupo com síndrome parkinsoniana atípica (n = 16), sendo os resultados comparados com um grupo controle (n = 18). Foram avaliadas as seguintes vari (mais) áveis: espessura da pars compacta do mesencéfalo, grau de hipointensidade de sinal no putâmen, grau de atrofia cerebral, lesões no mesencéfalo, lesões na substância branca e a presença de lesão na borda póstero-lateral do putâmen. A análise estatística dos dados foi realizada, com a utilização do programa SPSS. RESULTADOS: A média de idade foi de 58,2 anos nos grupos com doença de Parkinson e controle, e 60,5 anos no grupo com síndrome parkinsoniana atípica. Os pacientes com doença de Parkinson e síndrome parkinsoniana atípica apresentaram redução da espessura da pars compacta e maior grau de hipointensidade de sinal no putâmen. O grau de atrofia cerebral foi maior nos pacientes com síndrome parkinsoniana atípica. As lesões no mesencéfalo e na substância branca foram semelhantes entre os grupos. O sinal hiperintenso na borda póstero-lateral do putâmen foi um achado pouco freqüente na população estudada, mas sugestivo de atrofia de múltiplos sistemas. CONCLUSÃO: Desta forma, a ressonância magnética detectou alterações morfológicas cerebrais que podem auxiliar no diagnóstico por imagem das síndromes parkinsonianas. Resumo em inglês OBJECTIVE: The objective of this study was to evaluate the magnetic resonance imaging findings in patients with Parkinson's disease. MATERIALS AND METHODS: In the period from October 1999 to October 2002, 42 patients with parkinsonism were investigated using a 1.5 T MR equipment. Patients were divided into two groups: patients with Parkinson's disease (n = 26) and patients with atypical Parkinsonian syndrome (n = 16). The results were compared with a control group (n = 18 (mais) ). The following variables were evaluated: thickness of the mesencephalon compact pars, hypointense signal in the putamen, degree of brain atrophy, lesions in the mesencephalon, lesions in the white matter, and the presence of lesions in the posterior-lateral edge of the putamen. Statistical data analysis was carried out using the SPSS program. RESULTS: The mean age was 58.2 years for the Parkinson's disease and control groups, and 60.5 years for the atypical Parkinsonian syndrome group. Patients with Parkinson's disease and atypical Parkinsonian syndromes presented decreased thickness of the compact pars and a higher degree of signal hypointensity in the putamen. Cerebral atrophy was more prominent in the patients with atypical Parkinsonian syndrome. Lesions in mesencephalon and white matter were similar in both groups. The frequency of hyperintense signal in the posterior-lateral edge of the putamen was low within the studied population, although that could suggest multiple-system atrophy. CONCLUSION: Magnetic resonance imaging allows the detection of brain morphological changes that may help in the diagnosis of Parkinsonian syndromes.

Scientific Electronic Library Online (Portuguese)

69

Avaliação da concordância entre ressonância magnética de ultra-sonografia na classificação de fibrose periportal em esquitossomóticos, segundo a classificação de Niamey/ Agreement between magnetic resonance imaging and ultrasonography in the classification of schistosomal periportal fibrosis, according to Niamey's criteria

Scortegagna Junior, Eduardo; Leão, Alberto Ribeiro de Souza; Santos, José Eduardo Mourão; Sales, Danilo Moulin; Shigueoka, David Carlos; Aguiar, Luciane Aparecida Kopke de; Brant, Paulo Eugênio; Colleoni Neto, Ramiro; Borges, Durval Rosa; D'Ippolito, Giuseppe
2007-10-01

Resumo em português OBJETIVO: Avaliar a reprodutibilidade da ressonância magnética e a concordância entre a ultra-sonografia e a ressonância magnética na classificação da fibrose periportal em pacientes esquistossomóticos, segundo os critérios qualitativos de Niamey. MATERIAIS E MÉTODOS: Foi realizado estudo prospectivo e duplo-cego, entre fevereiro de 2005 e junho de 2006, em 20 pacientes (10 homens e 10 mulheres, idades entre 24 e 60 anos, média de 42,75 anos) com diagnóstico d (mais) e esquistossomose mansônica. As imagens de ultra-sonografia e de ressonância magnética foram avaliadas por dois examinadores experientes de forma independente. Foi medida a concordância interobservador para a ressonância magnética e entre a ressonância magnética e a ultra-sonografia. RESULTADOS: A ressonância magnética apresentou resultados concordantes entre os observadores em 14 pacientes (70%). Quando comparamos a ressonância magnética com a ultra-sonografia, obtivemos concordância em apenas seis pacientes pelo observador 1 (30%) e em oito pacientes pelo observador 2 (40%). CONCLUSÃO: A ressonância magnética tem boa reprodutibilidade na avaliação de fibrose periportal em pacientes com esquistossomose avançada, porém sua concordância com a ultra-sonografia é fraca. Resumo em inglês OBJECTIVE: To evaluate the reproducibility of magnetic resonance imaging and the agreement between ultrasound and magnetic resonance imaging in the classification of periportal fibrosis in patients with schistosomiasis based on Niamey's qualitative criteria. MATERIALS AND METHODS: A prospective, double-blinded study was conducted between February 2005 and June 2006 with 20 patients (10 men and 10 women, with ages ranging between 24 and 60 years, mean age 42.7 years) diagn (mais) osed with schistosomiasis mansoni. Both ultrasound and magnetic resonance images were independently evaluated by two experienced observers. Interobserver agreement was evaluated for findings of periportal fibrosis on magnetic resonance images and in a comparison between magnetic resonance and ultrasound images. RESULTS: The analysis of magnetic resonance images showed total interobserver agreement in 14 patients (70%). The comparison between ultrasound and magnetic resonance imaging showed agreement between images in only six cases (30%) by observer 1, and in eight cases (40%) by observer 2. CONCLUSION: Magnetic resonance imaging presents a good reproducibility in the evaluation of periportal fibrosis in later stages of schistosomiasis, however, the correlation between magnetic resonance imaging and ultrasound is poor.

Scientific Electronic Library Online (Portuguese)

70

Avaliação da concordância entre a ultrassonografia transvaginal e a ressonância magnética da pelve na endometriose profunda, com ênfase para o comprometimento intestinal/ Evaluation of agreement between transvaginal ultrasonography and magnetic resonance imaging of the pelvis in deep endometriosis with emphasis on intestinal involvement

Cardoso, Maene Marcondes; Werner Junior, Heron; Berardo, Plínio Tostes; Coutinho Junior, Antônio Carlos; Domingues, Marisa Nassar Aidar; Gasparetto, Emerson Leandro; Domingues, Romeu Côrtes
2009-04-01

Resumo em português OBJETIVO: Comparar achados ultrassonográficos e de ressonância magnética na endometriose profunda, com ênfase para o comprometimento intestinal. MATERIAIS E MÉTODOS: Dezoito pacientes entre 23 e 49 anos de idade, com suspeita clínica e exame ginecológico sugestivo de endometriose profunda, foram submetidas a ultrassonografia e ressonância magnética para correlação dos achados. RESULTADOS: A ultrassonografia detectou 40 lesões e a ressonância magnética detect (mais) ou 53 lesões na pelve. O estudo comparativo entre ultrassonografia e ressonância magnética na detecção das lesões não mostrou diferença estatística significativa (p > 0,19 e p > 0,14, respectivamente). Considerando-se a junção retossigmoide, a ressonância magnética detectou uma lesão (5,6%) e a ultrassonografia apontou quatro lesões (22,2%). Nas lesões retais, a ultrassonografia apontou oito lesões (44,4%) e a ressonância magnética, sete lesões (38,9%). CONCLUSÃO: A concordância entre a ressonância magnética e a ultrassonografia não foi boa na junção retossigmoide e no reto, sendo que a ultrassonografia detectou um número maior de lesões nessas localizações, mas identificou número menor de lesões na pelve. Na análise comparativa global entre os dois métodos na detecção das lesões não houve diferença estatística significativa. O baixo custo, a boa tolerabilidade e o fácil acesso tornam a ultrassonografia instrumento diagnóstico valioso na endometriose profunda. Resumo em inglês OBJECTIVE: To compare sonographic and magnetic resonance imaging findings in deep endometriosis with emphasis on intestinal involvement. MATERIALS AND METHODS: Eighteen women aged between 23 and 49 years with clinical suspicion and gynecological signs suggestive of deep endometriosis were submitted to ultrasonography and magnetic resonance imaging for correlation between findings. RESULTS: Ultrasonography detected 40 lesions while magnetic resonance imaging detected 53 le (mais) sions in the pelvis. A comparative study has not shown any statistically significant intermethod difference in the detection of lesions (respectively p > 0.19 and p > 0.14). In the rectosigmoid junction, magnetic resonance imaging has detected one (5.6%) lesion, while ultrasonography has detected four lesions (22.2%). In the rectum, ultrasonography has detected eight lesions (44.4%), and magnetic resonance imaging has detected seven lesions (38.9%). CONCLUSION: The intermethod agreement has not been good for lesions in the rectosigmoid junction, considering that ultrasonography has detected a higher number of lesions in this region, but a lower number of lesions in the pelvis as compared with magnetic resonance imaging. The global comparative analysis has demonstrated no statistically significant intermethod difference in the detection of lesions. Low cost, good tolerability and high availability make ultrasonography a valuable diagnostic tool in cases of deep endometriosis.

Scientific Electronic Library Online (Portuguese)

71

Avaliação da aterosclerose carotídea por intermédio de ultra-sonografia e ressonância magnética/ Evaluation of carotid atherosclerosis by ultrasound and magnetic resonance imaging

Souza, Lara Vilela de; Castro, Cláudio Campi de; Cerri, Giovanni Guido
2005-04-01

Resumo em português OBJETIVO: Identificar ateromas carotídeos em coronariopatas com indicação de terapia cirúrgica. Avaliar o grau de estenose das artérias carótidas internas por meio de ultra-sonografia com Doppler colorido (UDC) e angiografia por ressonância magnética (ARM). Comparar a ecogenicidade das placas visualizadas pela ultra-sonografia (US), com a intensidade de sinal nos exames de ressonância magnética (RM). Avaliar a qualidade de imagens e confiabilidade interobservado (mais) res nos exames de RM. MATERIAIS E MÉTODOS: Estudo prospectivo em 50 pacientes. Utilizamos US e RM em seqüências ponderadas em T1 e T2, ambas pelas técnicas "black-blood" (BB) e "fat sat black-blood" (FSBB), e ARM 3D TOF ("time-of-flight'') com e sem contraste paramagnético. RESULTADOS: Do total de 100 segmentos, 81% apresentaram estenose pela US. Em 72 placas com ecogenicidade tipo 4 houve aumento da intensidade de sinal em 59,7% em T1-BB, 65,3% em T1-FSBB, 62,5% em T2-BB e 66,7% em T2-FSBB. Nas placas tipo 2 houve aumento da intensidade de sinal em 71,4% em T1-BB e T1-FSBB, 85,7% em T2-BB e 71,4% em T2-FSBB. Nas placas tipo 1 houve aumento da intensidade de sinal em 50,0% em T1 e T2. Em 19 segmentos a US foi considerada normal. Quando estes segmentos foram avaliados pela RM, houve aumento da intensidade de sinal em 47,4% em T1-BB, 57,9% em T1-FSBB e 52,6% em T2-BB e T2-FSBB. CONCLUSÃO: Houve alta incidência de aterosclerose carotídea. Houve reprodutibilidade marginal na associação entre o grau de estenose visualizado pela UDC e ARM. Não houve correlação entre os tipos de ecogenicidade das placas visualizadas pela US com as alterações de intensidade de sinal pela RM. A qualidade de imagens dos exames de RM foi considerada ótima em T1 e T2 e muito boa em 3D TOF (axial). A qualidade de imagem dos exames de ARM foi excelente. Notou-se ótima reprodutibilidade interobservadores, com valores de índice kappa acima de 0,71. Resumo em inglês OBJECTIVE: To identify carotid plaques in patients with coronary disease and indication for surgical treatment. To evaluate the degree of stenosis of the internal carotid arteries using color Doppler ultrasound (CDU) and magnetic resonance angiography (MRA). To compare plaque ultrasound echogenicity with signal intensity in magnetic resonance imaging (MRI). To evaluate the quality of the images and inter-rater reliability of MRI analysis. MATERIALS AND METHODS: This was a (mais) prospective study of 50 patients. Imaging methods used included ultrasound, T1- and T2-weighted MRI sequences, both with black-blood (BB) and fat sat black-blood (FSBB) techniques, and 3D TOF (time-of-flight) MRA, with and without administration of paramagnetic contrast media. RESULTS: Out of a total of 100 arterial segments, 81% showed stenosis on ultrasound whereas in 72 plaques with type 4 echogenicity there was high signal intensity in MRI in 59.7% in T1-BB technique, 65.3% in T1-FSBB, 62.5% in T2-BB and 66.7% in T2-FSBB. In type 2 plaques we observed high signal intensity in 71.4% in T1-BB and T1-FSBB, 85.7% in T2-BB and 71.4% in T2-FSBB. In type 1 plaques there was high signal intensity in 50% on T1- and T2-weighted images. In 19 segments ultrasound was considered normal. The same segments showed high signal intensity in 47.4% in T1-BB, 57.9% in T1-FSBB, 52.6% in T2-BB and T2-FSBB when evaluated with MRI. CONCLUSION: A high incidence of carotid atherosclerosis was observed. There was borderline reproducibility in the association between the degree of stenosis observed by CDU and MRA. There was no correlation between the types of plaque echogenicity assessed by ultrasound and MR signal intensity changes. The quality of MR images was considered optimal on T1- and T2-weighted images, and good in 3D TOF (axial). The quality of MRA images was considered excellent. Optimal inter-rater reliability was observed, with a kappa index above 0.71.

Scientific Electronic Library Online (Portuguese)

72

Avaliação crítica dos benefícios e limitações da ressonância magnética como método complementar no diagnóstico das malformações fetais/ A critical review of benefits and limitations of magnetic resonance imaging as a complementary method in the diagnosis of fetal malformations

Ximenes, Renato Luis da Silveira; Szejnfeld, Jacob; Ximenes, Andréa Regina da Silveira; Zanderigo, Valdir
2008-10-01

Resumo em português OBJETIVO: Avaliar, por meio da ressonância magnética, uma série de fetos com diagnóstico ultra-sonográfico de malformação, a fim de estabelecer os benefícios e limites diagnósticos proporcionados pela técnica de ressonância magnética fetal, em comparação com a ultra-sonografia. MATERIAIS E MÉTODOS: Foram estudadas 40 mulheres entre 15-35 semanas de gestação com diagnóstico de anomalia fetal durante o exame de ultra-sonografia. As pacientes foram encaminh (mais) adas para o estudo complementar com ressonância magnética. As indicações para o estudo da ressonância magnética fetal foram: anomalias do sistema nervoso central, do tórax, do abdome, renais, esqueléticas e tumores. A avaliação pós-natal incluiu a revisão das imagens de ultra-sonografia e ressonância magnética, o acompanhamento do nascimento, exames laboratoriais, radiológicos e necropsia. RESULTADOS: Os resultados mostraram que os estudos complementares com ressonância magnética fetal trouxeram informações adicionais em 60% dos casos estudados. Os benefícios da ressonância magnética fetal foram: ampliação da avaliação global, aumento do campo de avaliação, maior resolução tecidual pelo uso de seqüências, e avaliação em pacientes obesas e com oligoidrâmnio. Os limites da ressonância magnética fetal foram: evitar exame no primeiro trimestre, avaliação do fluxo sanguíneo, movimentação fetal, claustrofobia materna, estudo do coração fetal e esqueleto. CONCLUSÃO: A ressonância magnética fetal pode ser utilizada como método complementar para a avaliação das malformações fetais. Resumo em inglês OBJECTIVE: The present study was aimed at evaluating by means of magnetic resonance imaging a series of fetuses with sonographic diagnosis of malformation, establishing the diagnostic benefits and limitations of fetal magnetic resonance imaging as compared with ultrasonography. MATERIALS AND METHODS: Forty women between 15-35 gestational weeks and previously diagnosed with fetal abnormality by ultrasonography were referred to undergo complementary fetal magnetic resonance (mais) imaging, particularly for evaluating abnormalities in the fetal central nervous system, thorax, abdomen, renal system, skeletal system, and tumors. The whole evaluation process included a review of the fetal ultrasonography and magnetic resonance images, postnatal follow-up, laboratory tests, imaging studies and necropsy. RESULTS: The present study has demonstrated that complementary magnetic resonance imaging did provide further information in 60% of cases, with the following benefits: improved information on the fetus as a whole, with a large field of view, higher anatomic resolution provided by fast sequences, superior soft tissue contrast resolution, besides the fact that the visualization of the fetus is not significantly affected by maternal obesity or oligohydramnios. Limitations of the method include contraindication in the first gestational trimester and in cases of maternal claustrophobia, sensitivity to fetal motion, low sensitivity for detecting cardiovascular and skeletal malformations. CONCLUSION: Fetal magnetic resonance imaging plays a significant role as a complementary method for the diagnosis of fetal anomalies.

Scientific Electronic Library Online (Portuguese)

73

Avaliação biométrica do colo uterino durante a gestação por meio da ultra-sonografia transvaginal e ressonância magnética/ Biometric analysis of uterine cervix during pregnancy using transvaginal ultrasonography and magnetic resonance imaging

Brandão, Rosieny Souza; Pires, Claudio Rodrigues; Souza, Eduardo de; Maciel Junior, Francisco da Silva; Moron, Antonio Fernandes; Mattar, Rosiane
2008-08-01

Resumo em português OBJETIVO: Avaliar o comprimento do colo uterino por meio da ressonância magnética e comparar aos achados da ultra-sonografia transvaginal. MATERIAIS E MÉTODOS: Foram realizados exames ultra-sonográficos e de ressonância magnética do colo uterino em 20 pacientes com idade gestacional entre 19 e 30 semanas. As medidas do colo obtidas pelo exame de ressonância magnética foram aferidas por dois especialistas em diagnóstico por imagem, para calcular a variabilidade in (mais) terobservador do método. RESULTADOS: O cálculo do coeficiente de correlação de Pearson entre as medidas do comprimento cervical indicou correlação significante entre os métodos (r=0,628; p Resumo em inglês OBJECTIVE: To evaluate the uterine cervix length with magnetic resonance imaging in comparison with findings at transvaginal ultrasonography. MATERIALS AND METHODS: Twenty pregnant women between the 19th and 30th gestational weeks underwent magnetic resonance imaging and transvaginal ultrasonography for evaluation of their uterine cervix. Measurements by means of magnetic resonance imaging were performed by two specialists in imaging diagnosis for calculating the interobs (mais) erver variability of the method. RESULTS: Calculation of the Pearson's correlation coefficient between measurements of the cervical length demonstrated a significant correlation between the results of both methods (r=0.628; p

Scientific Electronic Library Online (Portuguese)

74

Apresentações incomuns no diagnóstico por imagem do pseudotumor intraósseo do hemofílico/ Uncommon presentations of intraosseous hemophilic pseudotumor in imaging diagnosis

Santos, Marcel Koenigkam; Polezi, Mariana Basso; Engel, Edgard Eduard; Pastorello, Mônica Tempest; Simão, Marcelo Novelino; Elias Junior, Jorge; Nogueira-Barbosa, Marcello Henrique
2009-06-01

Resumo em português OBJETIVO: Este estudo tem como objetivo descrever apresentações incomuns do pseudotumor do hemofílico no diagnóstico por imagem. MATERIAIS E MÉTODOS: Estudo retrospectivo com avaliação de cinco pseudotumores ósseos do hemofílico em dois pacientes. Os achados de imagem em dois pacientes hemofílicos tipo A foram avaliados em consenso por dois radiologistas musculoesqueléticos. Foram estudados exames de radiografia simples, tomografia computadorizada e ressonânci (mais) a magnética. RESULTADOS: Em uma das lesões analisadas a fase pós-contraste intravenoso da tomografia computadorizada mostrou áreas de reforço heterogêneo e de aspecto sólido no interior da lesão da coxa direita. Este aspecto foi confirmado no exame anatomopatológico da lesão em questão. Outro achado raro foi a identificação de dois pseudotumores intraósseos no úmero, separados por segmento de osso normal. E, por fim, também um pseudotumor do fêmur com extensão para partes moles e transarticular, com conseqüente acometimento da tíbia e patela. CONCLUSÃO: Os achados de diagnóstico por imagem acima descritos não são comumente relatados para os pseudotumores ósseos do hemofílico. É importante que o radiologista tenha conhecimento dessas apresentações mais raras. Resumo em inglês OBJECTIVE: The present study was aimed at describing uncommon presentations of intraosseous hemophilic pseudotumor in imaging diagnosis. MATERIALS AND METHODS: Retrospective study evaluating five hemophilic pseudotumors in bones of two patients with hemophilia A. Imaging findings were consensually evaluated by two musculoskeletal radiologists. Plain radiography, computed tomography and magnetic resonance imaging studies were analyzed. RESULTS: At contrast-enhanced compute (mais) d tomography images, one of the lesions on the left thigh was visualized with heterogeneously enhanced solid areas. This finding was later confirmed by anatomopathological study. Another uncommon finding was the identification of a healthy bone portion interposed between two intraosseous pseudotumors in the humerus. And, finally, a femoral pseudotumor with extension towards soft tissues and transarticular extension, and consequential tibial and patellar involvement. CONCLUSION: The above described imaging findings are not frequently reported in cases of intraosseous pseudotumors in hemophilic patients. It is important that radiologists be aware of these more uncommon presentations of intraosseous pseudotumors.

Scientific Electronic Library Online (Portuguese)

75

Aplicação da ressonância magnética no acompanhamento da cirurgia do colesteatoma/ The role of magnetic resonance imaging in the postoperative management of cholesteatomas

Toyama, Carlos; Leite, Claudia da Costa; Baraúna Filho, Iulo Sérgio; Brito Neto, Rubens Vuono de; Bento, Ricardo Fereira; Cerri, Giovanni Guido; Gebrim, Eloisa Maria Melo Santiago
2008-10-01

Resumo em português A tomografia computadorizada e ressonância magnética (RM) com seqüências convencionais têm baixa especificidade para a diferenciação entre tecido de granulação e recidiva de colesteatoma. OBJETIVO: Avaliar a aplicação da RM com sequência de difusão e pós-contraste T1 tardio na detecção de recidiva de colesteatoma. MATERIAL E MÉTODO: Realizado estudo transversal prospectivo de dezessete pacientes estudados no pós-operatório de colesteatoma utilizando RM (mais) de 1.5 T com seqüência difusão, T1, T2 e pós-contraste T1 tardio nos planos coronal e axial. Dois radiologistas avaliaram e decidiram em consenso a presença de foco de hipersinal na difusão e T2, iso/hipossinal em T1 e ausência de impregnação pelo contraste como suspeitos de recidiva de colesteatoma. Os achados da revisão cirúrgica foram comparados com o resultado da RM. RESULTADOS: Onze dos doze casos de recidiva de colesteatoma apresentaram hipersinal na difusão. Todos os pacientes com tecido de granulação na cavidade cirúrgica não apresentaram alteração de sinal na difusão. Um paciente com abscesso no conduto auditivo interno também apresentou hipersinal na difusão. A sensibilidade, especificidade, valor preditivo positivo e negativo foram respectivamente 91,6%, 60%, 84,6% e 75%. CONCLUSÃO: A seqüência de difusão combinada com pós-contraste tardio pode ser útil na diferenciação entre tecido de granulação e recidiva de colesteatoma. Resumo em inglês Conventional CT and MRI scans have low specificity when it comes to differentiating granulation tissue from relapsing cholesteatoma. AIM: this paper aims to analyze the use of DWI and delayed post-contrast T1-weighed imaging in the detection of recurring cholesteatomas. MATERIALS AND METHOD: this is a cross-sectional prospective study that looked at 17 cholesteatoma patients postoperatively. All patients underwent diffusion magnetic resonance imaging at 1.5T, T1, T2, and (mais) delayed post-contrast T1 and images were produced from both coronal and axial planes. Two radiologists assessed the images and decided consensually that the presence of hyperintensive signal in DWI on T2, iso/hypointensive signal on T1, and absence of contrast uptake were indicative of relapsing cholesteatoma. Surgical review findings were compared to DWI scans. RESULTS: eleven of the twelve cases of recurring cholesteatoma presented hyperintensive signal in the DWI scans. None of the patients with granulation tissue in the surgical wound presented hyperintensive signal in the DWI scans. A patient with an abscess in the internal acoustic meatus also presented a hyperintensive signal in the DWI scans. Sensibility, specificity, positive predictive value and negative predictive value were 91.6%, 60.0%, 84.6%, and 75.0%, respectively. CONCLUSION: DWI combined with delayed post-contrast T1 SE sequence proved to be useful in the differential diagnosis of granulation tissue and recurring cholesteatoma.

Scientific Electronic Library Online (Portuguese)

76

Aplicação da ressonância magnética de corpo inteiro para o estadiamento e acompanhamento de pacientes com linfoma de Hodgkin na faixa etária infanto-juvenil: comparação entre diferentes sequências/ Whole-body magnetic resonance imaging for staging and follow-up of pediatric patients with Hodgkin's lymphoma: comparison of different sequences

Nava, Daniel; Oliveira, Heverton Cesar de; Luisi, Flavio Augusto; Ximenes, Andrea Regina da Silveira; Lederman, Henrique Manoel
2011-02-01

Resumo em português OBJETIVO: Comparar o desempenho das sequências T1, T2, STIR e DWIBS (difusão de corpo inteiro com supressão do sinal de fundo) na identificação de sítios caracterizados como acometidos pelo linfoma de Hodgkin nas cadeias linfonodais, órgãos parenquimatosos e medula óssea, e avaliar a concordância entre os examinadores. MATERIAIS E MÉTODOS: Foram estudados 12 pacientes com diagnóstico confirmado de linfoma de Hodgkin. Os pacientes foram encaminhados para o exam (mais) e de ressonância magnética, sendo realizadas as sequências ponderadas em T1, T2, STIR e DWIBS. RESULTADOS: O número de sítios linfonodais caracterizados como acometidos nas sequências ponderadas em T1 e T2 apresentaram resultados semelhantes (8 sítios), mas inferiores às sequências STIR e DWIBS (11 e 12 sítios, respectivamente). Quanto ao acometimento da medula óssea, observaram-se os mesmos valores para as sequências T1, T2 e DWIBS (17 lesões), superiores ao valor encontrado na sequência STIR (13 lesões). Quando realizada a comparação entre os examinadores, nota-se que há alta concordância entre as quatro sequências. CONCLUSÃO: As sequências STIR e DWIBS detectaram maior número de linfonodos caracterizados como acometidos. Todas as sequências apresentaram resultados semelhantes na avaliação dos órgãos parenquimatosos e medula óssea. Em todas as sequências analisadas houve alta concordância entre os examinadores. Resumo em inglês OBJECTIVE: To compare the performance of the T1, T2, STIR and DWIBS (diffusion-weighted whole-body imaging with background body signal suppression) sequences in the staging and follow-up of pediatric patients with Hodgkin's lymphoma in lymph node chains, parenchymal organs and bone marrow, and to evaluate interobserver agreement. MATERIALS AND METHODS: The authors studied 12 patients with confirmed diagnosis of Hodgkin's lymphoma. The patients were referred for whole body (mais) magnetic resonance imaging with T1-weighted, T2-weighted, STIR and DWIBS sequences. RESULTS: The number of lymph node sites characterized as affected by the disease on T1- and T2-weighted sequences showed similar results (8 sites for both sequences), but lower than DWIBS and STIR sequences (11 and 12 sites, respectively). The bone marrow involvement by lymphoma showed the same values for the T1-, T2-weighted and DWIBS sequences (17 lesions), higher than the value found on STIR (13 lesions). A high rate of interobserver agreement was observed as the four sequences were analyzed. CONCLUSION: STIR and DWIBS sequences detected the highest number of lymph node sites characterized as affected by the disease. Similar results were demonstrated by all the sequences in the evaluation of parenchymal organs and bone marrow. A high interobserver agreement was observed as the four sequences were analyzed.

Scientific Electronic Library Online (Portuguese)

77

Análise retrospectiva das urografias excretoras em um serviço de radiologia de um hospital geral/ Retrospective analysis of intravenous urography examinations in a radiology service of a general hospital

Nacif, Marcelo Souto; Jauregui, Gustavo Federico; Mendonça Neto, Alderico; Boechat, Ana Paula; Mello, Ricardo Andrade Fernandes de; Tostes, Rodrigo Bastos; Cruz, Flávio Carvalho; Santos, Alair Augusto Sarmet Moreira Damas dos
2004-12-01

Resumo em português OBJETIVO: Fazer uma revisão de 225 exames de urografia excretora, analisando estatisticamente as principais alterações relacionadas com o trato urinário, e reafirmar a utilidade do método. MATERIAIS E MÉTODOS: Estudo retrospectivo e descritivo realizado a partir de levantamento de 225 exames de urografia excretora realizados no período de 2/1/2002 a 29/11/2002, no Serviço de Radiologia do Hospital Santa Cruz da Beneficência Portuguesa de Niterói. RESULTADOS: Do (mais) total de 225 exames, 173 (76,9%) apresentaram alterações radiológicas (anatômicas, congênitas, adquiridas, funcionais, relacionadas a litíase, cirurgias e outros) e 52 (23,1%) foram normais. A alteração mais freqüente foi a urolitíase (35,9%), seguida da dilatação do sistema pielocalicial (9,9%). Observamos que 110 (48,9%) eram pacientes do sexo masculino e 115 (51,1%), do sexo feminino. O paciente mais jovem tinha apenas dois meses de idade e o mais idoso, 84 anos. CONCLUSÃO: Apesar do advento de novas técnicas diagnósticas como o ultra-som, a tomografia computadorizada e a ressonância magnética, a urografia excretora continua tendo importante papel diagnóstico, além de constituir excelente ferramenta de auxílio à programação cirúrgica do urologista. Resumo em inglês OBJECTIVE: To review 225 intravenous urography examinations in order to statistically analyze the main urinary tract related findings and to revalidate the usefulness of the method. MATERIALS AND METHODS: This is a retrospective and descriptive study based on data of 225 intravenous urography examinations performed between 2/1/2002 and 29/11/2002 at the Department of Radiology of "Hospital Santa Cruz/Beneficência Portuguesa de Niterói", Niterói, RJ, Brazil. RESULTS: In (mais) a total of 225 examinations, radiological findings (anatomical, congenital, acquired, functional and others) were seen in 173 (76.9%) whereas 52 (23.1%) examinations were normal. The most common finding was calculus (35.9%), followed by dilatation of the calyceal system (9.9%). One hundred and ten patients (48.9%) were male and 115 (51.1%) were female. The youngest patient was 2-month-old and the oldest was 84-year-old. CONCLUSION: In spite of the new imaging modalities such as ultrasound, computed tomography and magnetic resonance imaging, intravenous urography still remains an important and valuable method for the investigation of the urinary tract.

Scientific Electronic Library Online (Portuguese)

78

Análise do masseter, por espectroscopia de próton, em pacientes com esclerose sistêmica/ Proton spectroscopy study of the masseter in patients with systemic sclerosis

Marcucci, Marcelo; Abdala, Nitamar
2009-06-01

Resumo em português OBJETIVO: Avaliar a concentração de metabólitos no masseter em portadores de esclerose sistêmica, analisando os índices de creatina, colina, lipídio e lactato, e relacionar com a presença de osteólise mandibular. MATERIAIS E MÉTODOS: Foram selecionados 25 pacientes, sendo 15 com diagnóstico de esclerose sistêmica e agrupados de acordo com a presença (grupo I) ou ausência (grupo II) de osteólise, e 10 indivíduos normais (grupo III, controle). Todos foram sub (mais) metidos a exame de espectroscopia de próton por ressonância magnética, com técnica PRESS e aquisição tridimensional. RESULTADOS: O estudo dos metabólitos dos três grupos apresentou os mesmos valores absolutos de creatina e lipídio. Os pacientes do grupo I apresentaram maior quantidade de colina em relação aos do grupo III. Já os indivíduos dos grupos I e II apresentaram menor quantidade de lactato em relação aos indivíduos normais. Os índices creatina/lipídio e colina/lactato foram os mesmos em todos os grupos. CONCLUSÃO: Observamos menor quantidade de lactato nos pacientes com esclerose sistêmica (grupos I e II). A colina está aumentada nos pacientes com osteólise mandibular (grupo I). Os índices creatina/colina, creatina/lactato, lipídio/lactato e colina/lipídio foram diferentes entre os grupos estudados. Mais estudos são necessários para a compreensão da participação do masseter no desenvolvimento da osteólise mandibular. Resumo em inglês OBJECTIVE: To evaluate metabolite concentration in the masseter of patients with systemic sclerosis, by analyzing creatine, choline, lipid and lactate levels, and correlating them with the presence of mandibular osteolysis. MATERIALS AND METHODS: The sample included 25 individuals, 15 of them with diagnosis of systemic sclerosis, divided into two groups according to the presence (group I) or absence (group II) of osteolysis, and 10 healthy individuals (group III, control) (mais) . All of them were submitted to proton magnetic resonance spectroscopy with PRESS sequence and 3D acquisition. RESULTS: Metabolite analysis showed that the creatine and lipid levels were the same for the three groups. Patients in group I presented higher levels of choline when compared with group III. On the other hand, lower lactate levels were observed in groups I and II when compared with the healthy individuals. Creatine/lipid and choline/lactate ratios were the same in the three groups. CONCLUSION: Lower lactate levels were observed in the patients with systemic sclerosis (groups I and II). Choline levels were increased in the patients with mandibular osteolysis (group I). Creatine/choline, lipid/lactate and choline/lipid ratios were different among the three groups. Further studies are necessary to understand the role played by the masseter in the development of mandibular osteolysis.

Scientific Electronic Library Online (Portuguese)

79

Anomalias aerogamaespectrométricas (K, eU e eTh) da quadrícula de Araras (SP) e suas relações com processos pedogenéticos e fertilizantes fosfatos

Souza, Jocelyn Lopes de; Ferreira, Francisco José Fonseca
2005-09-01

Resumo em português Radionuclídeos estão presentes nas matérias-primas utilizadas para a fabricação de alguns fertilizantes e, conseqüentemente, a redistribuição de urânio, tório e potássio pela atividade agrícola pode levar a contaminação dos solos intensivamente fertilizados. Dados aerogamaespectrométricos de K, eU e eTh mostraram, na Quadrícula de Araras (SP), a coincidência entre valores radiométricos anômalos e sills de diabásio. Esta área está localizada no estado (mais) de São Paulo, situada entre as coordenadas 22º 00'/22º 30' de latitude sul e 47º 00' e 47º 30' de longitude oeste. O processamento e a integração dos dados de geologia, de solos, de formações superficiais, de drenagem, topográficos, de sensoriamento remoto e geofísicos, em ambiente de Sistemas de Informações Geográficas (SIG), através das geotecnologias, revelaram que: (i) as anomalias de eU e eTh ocorrem sobre Latossolos Roxos massivamente fertilizados com fosfatos, nas porções planas e elevadas do terreno; (ii) os níveis elevados de urânio estão associados a granulometria argilosa em regolitos sobre soleiras diabásicas; (iii) anomalias de potássio e tório acompanham os aluviões do Quaternário que percorrem as margens do Rio Moji, atribuindo-se às ocorrências de K anômalo a presença de feldspatos nos solos inseridos, e a ocorrência de eTh associada à fertilização local e ao transporte por argilas e óxidos de ferro provenientes das porções mais elevadas do terreno, onde situam-se os Latossolos Roxos sob a cultura de cana-de-açúcar. Das análises radioquímicas de U e Th em fertilizantes, observou-se a influência da origem geológica da fonte da matéria-prima utilizada para o seu fabrico, bem como o aumento nas concentrações de urânio com o teor de P2O5 do fertilizante. Medidas gamaespectrométricas terrestres mostraram boas relações com as detecções aerogamaespectrométricas. As informações gamaespectrométricas aliadas a detecções de susceptibilidade magnética (k) mostraram que o urânio e o tório tendem a se concentrar em solos oriundos do intemperismo de rochas básicas, mais desenvolvidos, argilosos e com k elevados. A retenção de urânio e tório em solos argilosos, aliada a informações de topografia, denotaram contagens gamaespectrométricas destes radionuclídeos maiores do que as encontradas na rocha fonte (sills de diabásio). Resumo em inglês Radionuclides are present in the raw materials utilized in the manufacturing of some fertilizers and, consequently, the redistribution of uranium, thorium and potassium by agricultural activities may lead to the contamination of intensively fertilized soils. Airborne gamma-ray data on K, eU and eTh have shown the coincidence of aerogammaspectrometric anomalies and diabase sills in the Araras region (SP). This area is situated between the coordinates latitude 22º 00'/22º (mais) 30' south and longitude 47º 00' and 47º 30' west. As the contents of radionuclides in basic rocks are low and aerial gamma-ray surveys reveal gamma radiation from the 30 cm of the soil profile (coinciding with topsoil), interest has been raised to investigate which soils are included in the anomalies reported, as well as what sort of agricultural activity is carried out, in order to attest whether the source of radioactivity originated from the chemical fertilizers applied, thus establishing the main purpose of the present research. Integration by GIS has revealed that (i) eU and eTh anomalies occur on Latossolos Roxos massively fertilized with phosphates, on the level and elevated parts of the terrain; (ii) high levels of uranium are associated with clay particle size in regoliths developed on diabase sills; (iii) potassium and thorium anomalies follow Quaternary alluviums which extend along the banks of the Moji river, the occurrence of anomalous K accounting for the presence of feldspars in the included soils, and the occurrence of eTh related to local fertilization and to the transport of clays and iron oxides from the uppermost parts of the terrain, where the Latossolos Roxos under sugarcane are located. Radiochemical analyses of U and Th in fertilizers were in agreement with the literature, and it has been observed the influence of the geological genesis of the source of the raw material utilized in the production of the fertilizer, as well as the increase in uranium concentrations along with the P2O5 content. Ground gamma-ray spectrometric measurements have shown good correlation with the airborne gamma-ray detections. In conjunction with magnetic susceptibility (k) readings have shown that uranium and thorium tend to concentrate in soils originated from the weathering of basic rocks, more developed, of clay texture, and predominance iron oxides. The retention higher than the ones found in diabase quarry.

Scientific Electronic Library Online (Portuguese)

80

Angiografia por ressonância magnética na avaliação das artérias renais: achados de imagem/ Magnetic resonance angiography in the evaluation of renal arteries: imaging findings

Nacif, Marcelo Souto; Santos, Alair Augusto Sarmet Moreira Damas dos; Marchiori, Edson
2006-08-01

Resumo em português OBJETIVO: Descrever as indicações, os principais diagnósticos e os achados de imagem nas angiografias por ressonância magnética das artérias renais. MATERIAIS E MÉTODOS: Estudo retrospectivo, no período de 6/12/2001 a 11/3/2004, num total de 56 exames, totalizando 111 artérias renais estudadas. Os exames foram realizados em um equipamento de 1,5 tesla, segundo o protocolo do Serviço. RESULTADOS: Foi demonstrado que 55,4% (n = 31) pacientes eram masculinos e 44,6 (mais) % (n = 25), femininos. O paciente mais novo tinha 12 anos e o mais velho, 88 anos. De um total de 25 diferentes indicações, a hipertensão arterial sistêmica com 26,7% (n = 15) foi a principal, seguida de dor abdominal e/ou lombar com 12,5% (n = 7), aneurisma da aorta abdominal com 10,7% (n = 6), estenose da artéria renal com 8,9% (n = 5), e outros. No que se refere às imagens, 43 (76,7%) exames tiveram algum tipo de alteração e 13 (23,2%) foram normais. Dentre os que tinham alterações, a maioria se deu no calibre, e dentre elas, as irregularidades parietais, aneurismas e estenoses foram as mais comuns. Na artéria renal direita as alterações mais comuns foram as irregularidades parietais com 17,87% (n = 10), e na artéria renal esquerda foram as estenoses com 25,45% (n = 14). CONCLUSÃO: A angio-RM mostrou-se excelente método no estudo das artérias renais, devido à sua sensibilidade e capacidade multiplanar para avaliar as estruturas vasculares. Resumo em inglês OBJECTIVE: To describe indications, main findings and diagnosis of magnetic resonance angiographies of renal arteries. MATERIALS AND METHODS: A retrospective study including 56 imaging studies covering a total of 111 renal arteries, performed during the period between December 6, 2001 and March 11, 2004. The angiographies were performed in a 1.5 T scanner, in compliance with the Department protocol. RESULTS: As regards sex, it was found that 55.4% (n = 31) patients were m (mais) ale and 44.6% (n = 25) were female. The youngest patient was 12 years old and the oldest 88 years old. From a total of 25 different clinical indications, systemic arterial hypertension was the principal one with 26.7% (n = 15), followed by abdominal and/or lumbar pain with 12.5% (n = 7), abdominal aortic aneurysm with 10.7% (n = 6), renal artery stenosis with 8.9% (n = 5), and others. Among these 56 studies, 43 (76.7%) had different types of findings and 13 (23.2%) were normal. The majority of findings were related to vascular diameter and amongst them, parietal irregularities, aneurysms and stenosis were the most frequent. Parietal irregularity was the most frequent alteration in the right renal artery, with 17.87% (n = 10), and stenosis was the most frequent alteration in the left renal artery, with 25.45% (n = 14). CONCLUSION: Magnetic resonance angiography has shown to be an excellent non-invasive method for evaluation of renal arteries, because of its sensitivity and multiplanar capacity for demonstrating vascular structures.

Scientific Electronic Library Online (Portuguese)

81

Alterações parenquimatosas na trombose venosa cerebral: aspectos da ressonância magnética e da angiorressonância/ Parenchymal abnormalities in cerebral venous thrombosis: findings of magnetic resonance imaging and magnetic resonance angiography

Ferreira, Clécia Santos; Pellini, Marcos; Boasquevisque, Edson; Souza, Luís Alberto M. de
2006-10-01

Resumo em português OBJETIVO: Determinar a freqüência e localização das alterações parenquimatosas da trombose venosa cerebral nos exames de ressonância magnética e de angiorressonância, bem como a correlação com o território e a drenagem venosa comprometida. MATERIAIS E MÉTODOS: Foram analisados exames de 21 pacientes realizados entre 1996 e 2004, com diagnóstico clínico e radiológico de trombose venosa cerebral em exames de ressonância magnética e de angiorressonância na (mais) s seqüências 2D PC, 3D PC e 3D TOF com contraste paramagnético. Análise estatística foi realizada com o teste do qui quadrado. Quatro pacientes tinham exames de controle e três realizaram angiografia por subtração digital. RESULTADOS: Dos 21 pacientes, 18 eram mulheres, todos com idade entre três e 82 anos (média de 40 anos e mediana de 36 anos). Os principais fatores etiológicos foram infecção, uso de contraceptivos orais, reposição hormonal e colagenoses. Predominaram os sintomas de déficit focal, cefaléia, alteração do nível de consciência e convulsões. Por freqüência, as manifestações parenquimatosas foram: edema/infarto de distribuição cortical e/ou subcortical, congestão venosa e circulação colateral, realce meníngeo e infarto ou edema dos tálamos e núcleos da base. Os principais seios comprometidos foram o sagital superior, o transverso esquerdo, o sigmóide esquerdo e o seio reto, sendo incomum o acometimento dos seios cavernosos e de veias corticais. CONCLUSÃO: A trombose venosa cerebral é causa incomum de acidente vascular encefálico, com prognóstico favorável pelo caráter reversível das lesões. Seu diagnóstico depende fundamentalmente da capacidade do radiologista reconhecer suas formas de apresentação, principalmente nos casos em que ele é sugerido pelas alterações parenquimatosas e não necessariamente pela visualização do trombo. A precisão e a rapidez no diagnóstico permitem o pronto tratamento, reduzindo a morbi-mortalidade da doença. Resumo em inglês OBJECTIVE: To determine the frequency and localization of parenchymal abnormalities in cerebral venous thrombosis on magnetic resonance imaging and magnetic resonance angiography as well as their correlation with the territory and affected venous drainage. MATERIALS AND METHODS: Retrospective analysis (1996 to 2004) of 21 patients (3 male and 18 female) age range between 3 and 82 years (mean 40 years, median 36 years) with clinical and radiological diagnosis of cerebral v (mais) enous thrombosis on magnetic resonance imaging and magnetic resonance angiography in 2D PC, 3D PC and contrast-enhanced 3D TOF sequences. The statistical analysis was performed with the qui-square test. Four patients had follow-up exams and three patients underwent digital subtraction angiography. RESULTS: Main predisposing factors were: infection, use of oral contraceptives, hormone replacement therapy and collagenosis. Predominant symptoms included: focal deficit, headache, alteration of consciousness level and seizures. Most frequent parenchymal manifestations were: cortical/subcortical edema or infarct, venous congestion and collateral circulation, meningeal enhancement and thalamic and basal ganglia edema or infarct. Occlusion occurred mainly in superior sagittal, left transverse, left sigmoid and straight sinuses. Cavernous sinus and cortical veins thrombosis are uncommon events. CONCLUSION: Cerebral venous thrombosis is an uncommon cause of stroke, with favorable prognosis because of its reversibility. Diagnosis is highly dependent on the radiologist capacity to recognize the presentations of this disease, principally in cases where the diagnosis is suggested by parenchymal abnormalities rather than necessarily by visualization of the thrombus itself. An accurate and rapid diagnosis allows an immediate treatment, reducing the morbidity and mortality rates.

Scientific Electronic Library Online (Portuguese)

82

A ressonância magnética para o diagnóstico das lesões condrais, meniscais e dos ligamentos cruzados do joelho/ Magnetic resonance imaging for diagnosis of the chondral, meniscal and cruciate ligaments injuries of the knee

Karam, Francisco Consoli; Silva, Jefferson Luís Braga da; Fridman, Marcos William; Abreu, Armando; Arbo, Rodrigo Di Mare; Abreu, Marcelo; Vieira, José Francisco; Pires, Luiz Antônio Simões
2007-06-01

Resumo em português OBJETIVO: Avaliar o valor diagnóstico da ressonância magnética (RM) do joelho. MATERIAIS E MÉTODOS: Setenta e dois pacientes foram submetidos a RM previamente à artroscopia do joelho realizada por um único cirurgião e considerada como método padrão. Verificou-se a sensibilidade, a especificidade, os valores de verossimilhança e a concordância entre o radiologista e o ortopedista em classificar as lesões. RESULTADOS: O coeficiente de concordância kappa entre a (mais) RM e a artroscopia, em classificar as lesões, foi muito bom para lesões de ligamento cruzado anterior (0,84), bom para o menisco lateral (0,75), razoável para o menisco medial (0,50) e baixo para lesões condrais (menor que 0,50). A RM mostrou ter alta sensibilidade para rupturas de ligamento cruzado anterior (94%) e menisco medial (92%), boa sensibilidade para lesões de menisco lateral (80%) e baixa sensibilidade para lesões em todas as zonas condrais (menor que 50%), enquanto a especificidade foi excelente para todas as estruturas condrais, ligamentares e para o menisco lateral estudadas (maior que 97%) e razoável para o menisco medial (65%). CONCLUSÃO: A RM é uma ferramenta útil para subsidiar o diagnóstico clínico de lesões intra-articulares do joelho, como já foi mostrado em resultados semelhantes encontrados na literatura produzida no Brasil e no exterior. Resumo em inglês OBJECTIVE: To evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) of the knee. MATERIALS AND METHODS: Seventy-two patients have been submitted to MRI previously to arthroscopy of the knee performed by a single surgeon and utilized as a comparative standard method. Sensitivity, specificity, values of likelihood and rate of interobserver agreement have been evaluated. RESULTS: The kappa agreement coefficient between MRI and arthroscopy was very good for les (mais) ions in the anterior cruciate ligament (0.84), good for lateral meniscus (0.75), reasonable for medial meniscus (0.50) and poor for chondral lesions (

Scientific Electronic Library Online (Portuguese)

83

A ressonância magnética do quadril na avaliação de pacientes com artrite reumatóide: estudo descritivo/ Magnetic resonance imaging of the hip in rheumatoid arthritis patients: a descriptive study

Caldana, Wanda Chiyoko Iwakami; Ciconelli, Rozana Mesquita; Juliano, Yara; Fernandes, Artur da Rocha Corrêa
2005-08-01

Resumo em português OBJETIVO: Avaliar o valor da ressonância magnética (RM) como modalidade diagnóstica de imagem em pacientes com artrite reumatóide e estimar a freqüência das alterações no quadril em pacientes sintomáticos e assintomáticos. MATERIAIS E MÉTODOS: Foram avaliados 40 pacientes (17 sintomáticos e 23 assintomáticos) em equipamento de RM com 1,5 T, com o uso do contraste endovenoso. Os achados de RM foram subdivididos em alterações inflamatórias, degenerativas, mi (mais) stas (inflamatórias e degenerativas) e extra-articulares. RESULTADOS: As alterações mais freqüentes na RM de quadril dos pacientes sintomáticos e assintomáticos foram dos tipos degenerativas (22,5%) e extra-articulares (22,5%). Apenas cinco dos pacientes sintomáticos apresentaram achados inflamatórios (12,5%), sendo quatro (10%) com alterações degenerativas associadas (alterações mistas). CONCLUSÃO: O estudo permitiu avaliar as principais alterações encontradas em pacientes portadores de artrite reumatóide pela RM. As alterações mais freqüentes na RM do quadril desses pacientes foram dos tipos degenerativas e extra-articulares (22,5% de cada grupo). Apenas cinco dos pacientes sintomáticos apresentaram achados inflamatórios (12,5%), sendo quatro (10%) com alterações degenerativas associadas. Resumo em inglês OBJECTIVE: To assess the usefulness of MRI as a diagnostic method in patients with rheumatoid arthritis, and to evaluate the frequency of changes in the hip in symptomatic and asymptomatic patients. MATERIALS AND METHODS: Forty patients (17 symptomatic and 23 asymptomatic) were evaluated by 1.5 T magnetic resonance imaging (MRI) after intravenous contrast media injection. MRI findings were divided in inflammatory, degenerative, combined (inflammatory and degenerative) and (mais) extra-articular changes. RESULTS: The most frequent findings seen were degenerative and extra-articular changes (22.5% each). Inflammatory changes were seen in only five (12.5%) symptomatic patients, four of them with degenerative findings associated (10%). CONCLUSION: The use of MRI of the hip allowed the evaluation of the main articular abnormalities seen in patients with rheumatoid arthritis. The most frequent findings were degenerative and extra-articular changes. Inflammatory findings were seen in only five patients, four of them with degenerative changes associated.

Scientific Electronic Library Online (Portuguese)