Sample records for lithium 4
from WorldWideScience.org

Sample records 1 - 12 shown.



1

Produção de dióxido de manganês eletrolítico para uso em baterias de lítio/ Production of electrolytic manganese dioxide for usage in lithium batteries

Laurindo, Edison A.; Amaral, Fábio A.; Santos, Márcio L. dos; Ferracin, Luiz C.; Carubelli, Ademir; Bocchi, Nerilso; Rocha-Filho, Romeu C.
1999-07-01

Resumo em inglês The e phase of electrolytic manganese dioxide (EMD) is the structural form most easily converted in the LiMn2O4 spinel used as cathode in lithium batteries. Thus, employing titanium as anode, a study of electrolysis parameters was carried out in order to determine the best conditions to produce an e-EMD suitable for that spinel preparation. The influence of solution temperature (65oC and 90oC) and current density (betw (mais) een 1 mA/cm2 and 17.5 mA/cm2) on the anode potential and the EMD properties was investigated using an aqueous 2.0 mol/L MnSO4 + 0.30 mol/L H2SO4 solution. In any of the electrolysis conditions tested only the e-EMD structure was obtained, but its specific surface area varied with the applied current density and temperature. Drying the e-EMD at temperatures between 60oC and 120oC did not cause any phase changes. To produce a suitable EMD at the highest current density possible without passivation of the titanium anode, the best electrolysis parameters were determined to be 90oC and 15 mA/cm2. The e-EMD thus obtained had a specific surface area (BET) of ca. 65 m2/g.

Scientific Electronic Library Online (Portuguese)

2

Cardiomioplastia: novo gerador da Biotronic/ Cardiomyoplasty: a new Biotronic generator

Braile, Domingo M; Soares, Marcelo J. F; Souza, Dorotéia R. S; Schaldach, Max
1994-03-01

Resumo em português Na cardiomioplastia, a contração do músculo esquelético, submetido à estimulação elétrica sobre a parede ventricular dilatada, aumenta a função ventricular, que é dependente das condições prévias do coração e da doença de base. Um dos problemas principais que interfere no sucesso da substituição do músculo cardíaco é a estimulação sincrónica do miocárdio e o músculo esquelético. A estimulação desse músculo a longo prazo tem sido possível gr (mais) aças a eletrodos especiais associados à estimulação progressiva seqüencial, adaptando-o à função cardíaca, através da transformação gradual de fibras glicolíticas expostas à fadiga em oxidativas lentas altamente resistentes. O gerador de pulsos "Myos" (Biotronik) tem sido utilizado em nosso Serviço para estimulação elétrica do músculo grande dorsal em sincronização com o miocárdio. Esse tipo de cardiomioestimulador com circuito eletrônico e bateria de lítio armazena um programa de estimulação responsável por diferentes modos operacionais, adaptados por um programa de computação. Para a programação do cardiomioestimulador, o momento da sincronização do trem de pulso com a abertura da valva aórtica é de extrema importância. O modo M de alta velocidade é utilizado para avaliar este sincronismo. A avaliação clínica da cardiomioplastia tem como base os resultados obtidos de 32 pacientes, com idade de 22 a 72 anos (média = 46,2 anos). A maioria (72%) dos pacientes apresentou miocardiopatia dilatada por causa indeterminada, 24% de origem chagásica, 3% virótica e 3% por periparto. Os índices de mortalidade hospitalar e tardia foram ambos de 12,5% e de 3,1%, respectivamente, excluindo-se os chagásicos. A sobrevida atuarial foi de 81,3+-0,22% após 6 anos e de 94.4+-0,1 % após 5 anos, retirando-se os chagásicos. Os índices médios de diâmetros sistólico (55,1 mm), diastólico (70,7 mm), encurtamento segmentar (22,8%) e fração de ejeção (51,0%), referentes a seguimento médio de 14,2 meses, refletem que a cardiomioplastia pode ser efetiva na assistência do ventrículo esquerdo. A escolha do paciente parece ser a chave para o bom resultado operatório a curto e longo prazos. Resumo em inglês In the cardiomyoplasty, the contraction of the skeleton muscle, undergone electric stimulation on the dilated ventricle wall, increases the ventricle function, which is dependent of the heart and the base disease previous conditions. One of the main problems which interferes with the sucess of the cardiac muscle replacement is the myocardial synchronic stimulation and the skeleton muscle. The stimulation of this muscle in long-term has been possible because of the special (mais) electrodes associated with the sequential progressive stimulation, adjusting it to the cardiac function, through the gradual transformation of glicolitic fibers exposed to fatigue in highly resistant slow oxidizers. The pulse generator Myos (Biotronik) has been used in our center for electrical stimulation of the latissimus dorsalis in synchronization with the myocardium. This electronic circuit and lithium battery type of cardiomyostimulator stores a stimulation program responsible for different operational modes, adapted by acomputer program. In order to program the cardiomyostimulator, the moment of the pulse synchronization with the aortic valve opening is extremely important. The high velocity M mode is utilized to evaluate the synchronism. The cardiomyoplasty clinical evaluation is based on the results obtained from 32 patients at 22 ti 72 years old (average=46.2 years) most of patients (72%) presented dilated myocardiopathy due to undetermined cause, 24% of chagasic origin, 3% virus and 3% due to peripartum. Hospital and late mortality rate were both 12.5% and 3.1% and 3.7% respectively, excluding the chagasic patients. The actuarial survival was 81.3 + - 0.22% after 6 years and 94.4 + - 0.1 % after 5 years, withdrawing the chagasic patients. The average indexes of systolic diameters (55,1 mm), diastolic (70,7 mm), segmental shortening (22.8%) and ejection fraction (51.0%), related to an average follow-up of 14.2 months, reflect that the cardiomyoplasty can be effective to assist the left ventricle. Choosing the right patient seems to be key to the goog operative result in short and long terms.

Scientific Electronic Library Online (Portuguese)

3

Uso do processo sol-gel na obtenção de materiais híbridos organo-inorgânicos: preparação, caracterização e aplicação em eletrólitos de estado sólido/ Utilization of the sol-gel process to obtain organic-inorganic hybrid materials: preparation, characterization and application as solid state electrolytes

Zoppi, Rita A; Nunes, Suzana P
1997-12-01

Resumo em português Neste trabalho é descrita a preparação de materiais híbridos constituídos de um copolímero orgânico contendo segmentos óxido de etileno e de sílica. A rede inorgânica foi formada na solução polimérica a partir da hidrólise e condensação do tetraetoxisilano, TEOS. Como copolímero foi utilizado o poli(óxido de etileno-b-amida-6), PEBAX. Foram preparados também híbridos contendo perclorato de lítio, denominados aqui híbridos eletrólitos. Os materiais f (mais) oram caracterizados por microscopia eletrônica de transmissão, ensaios de tensão-deformação, análise dinâmico-mecânica e difratometria de raios-X. Os sistemas PEBAX/TEOS/LiClO foram também caracterizados por espectroscopia de impedância eletroquímica e voltametria cíclica para avaliação de suas propriedades como eletrólito de estado sólido. Resumo em inglês In this work it was described the preparation of hybrid materials constituted by a organic copolymer, which contains ethylene oxide blocks, and silica. The inorganic network was formed by the hydrolysis and condensation of tetraethoxysilane, TEOS, into the polymeric solution. As a copolymer, it was used poly(ethylene oxide-b-amide-6), PEBAX. Hybrids containing lithium perchlorate, known as hybrid electrolytes, were also prepared. The materials were characterized by transm (mais) ission electron microscopy, stress-strain tests, dynamic-mechanical analysis and X-ray diffractometry. The PEBAX/TEOS/LiClO4 systems were also characterized by electrochemical impedance spectroscopy and cyclic voltammetry to evaluate their properties as a solid state electrolyte.

Scientific Electronic Library Online (Portuguese)

4

Espectroscopia de impedância e microestrutura de vitrocerâmicas Li1+x[Al xGe2-x(PO4) 3] condutoras por íons lítio/ Impedance spectroscopy and microstructure of lithium conductor Li1+x[Al xGe2-x(PO4 )3] glass ceramics

Cruz, A. M.; Rodrigues, A. C. M.
2007-06-01

Resumo em português A fase Li1,5[Al0,5Ge1,5(PO4) 3] foi obtida via vitrocerâmica. Com o objetivo de se obter amostras com diferentes microestruturas, o vidro precursor do sistema Li2O-Al2O3-GeO2-P 2O5 foi submetido a tratamentos térmicos duplos. As amostras foram primeiramente nucleadas na temperatura de transição vítrea por diferentes tempos, e posteriormente cristalizados a 571 ºC. Foi também obtida uma vitrocerâmica por tratamento térmico simples a 618 ºC por 30 min. A caracteri (mais) zação por difração de raios X revela que a fase NASICON é a única fase presente após a cristalização. A caracterização elétrica foi realizada por espectroscopia de impedância, no intervalo de temperatura entre a ambiente e 120 ºC. Para algumas das amostras obtidas, os espectros de impedância mostram dois semicírculos evidenciando a presença de duas contribuições diferentes na condutividade elétrica, sempre próxima a 10-5 S/cm à temperatura ambiente. A energia de ativação de condução variou de H" 0,36 a 0,49 eV. A análise por microscopia eletrônica de varredura revela que tratamentos térmicos com tempos menores de nucleação geram amostras com grão maiores. Por outro lado, os resultados de condutividade elétrica indicam que as amostras com grãos maiores são mais condutoras. Resumo em inglês The highly conductive Li1.5[Al0.5Ge1.5(PO4) 3] phase was obtained by a glass-ceramic route. To achieve different microstructures, the parent Li2O-Al2O3-GeO2-P 2O5 glass was submitted to double heat treatments. Glasses were first nucleated for different periods of time at the temperature of glass transition and then subsequently fully crystallized at 571 ºC. A glass-ceramic was also obtained by simple heat treatment at 618 ºC for 30 min. X-Ray diffraction analyses show t (mais) hat, after crystallization, the NASICON phase is the unique phase present. Electrical characterization was carried out by impedance spectroscopy, from room temperature to 120 ºC. Impedance complex plane plots of some samples reveal two semicircles, enabling the identification of two contributions to the total electrical conductivity, which was close to 10-5 S/cm at room temperature. Activation energy varied from 0.36 eV to 0.49 eV. Scanning electron microscopy analysis confirms that heat treatments with shorter nucleation time lead to samples with higher grain size. Moreover, electrical measurements show that samples with larger grain size present a higher ionic conductivity.

Scientific Electronic Library Online (Portuguese)

5

Avaliação físico-química de águas minerais comercializadas na região de Campinas, SP/ Physical-chemical evaluation of mineral waters marketed in Campinas, SP

Morgano, Marcelo A.; Schatti, Ana Cláudia; Enriques, Hercília A.; Mantovani, Dilza M.B.
2002-12-01

Resumo em português Com o objetivo de avaliar a qualidade de águas minerais, foram analisadas amostras, adquiridas em supermercados, de oito fontes localizadas no Estado de São Paulo entre agosto de 1999 e maio de 2000, com coletas trimestrais. Os resultados das análises físico-químicas mostraram que as amostras possuíam, em sua maioria, composição química dentro dos limites permitidos pela legislação brasileira, exceto quatro amostras, que apresentaram resultados na análise de c (mais) or acima de 5 unidades PtCo, uma amostra com pH fora da faixa recomendada de 4,0 a 9,0 e uma amostra com alcalinidade em hidróxidos em duas épocas de análise. Os resultados obtidos para as diferentes amostras variaram de acordo com as seguintes faixas: pH de 6,39 a 9,92, alcalinidade de 0,0 a 189,1mg L-1 de bicarbonato, dureza de 0,00 a 136,00mg L-1 de carbonato de cálcio, cor de 0,0 a 9,0 unidades de PtCo, turbidez de 0,00 a 2,00 FTU de turvação, sulfato de 0,00 a 55,67mg L-1, sulfeto de 0,00 a 0,002mg L-1, cloreto de 0,00 a 23,53mg L-1, fluoreto de 0,02 a 0,8mg L-1, alumínio de 0,01 a 0,09mg L-1, bário de 0,00 a 0,26mg L-1, cálcio de 0,53 a 28,35mg L-1, crômio de 0,00 a 0,01mg L-1, ferro de 0,00 a 0,03mg L-1, potássio de 0,39 a 3,27mg L-1, sódio de 0,53 a 97,29mg L-1, magnésio de 0,00 a 9,10mg L-1, manganês de 0,00 a 0,05mg L-1, zinco de 0,00 a 0,03mg L-1, chumbo de 0,00 a 0,01mg L-1 e lítio de 0,00 a 0,02mg L-1. Os elementos cádmio, cobre e cobalto apresentaram-se abaixo dos limites de detecção dos métodos. Resumo em inglês Samples from eight different sources of mineral water from São Paulo State were purchased from August 1999 to May 2000 in order to evaluate the physical-chemical quality. In general, most samples were within the limits permited by the Brazilian legislation, except for four samples which showed color results above 5 PtCo units, one sample with pH outside the recommended range (pH 4 to 9) and one sample which presented hydroxide alkalinity in two different periods of sampl (mais) ing. The results varied according to the following ranges: pH from 6.39 to 9.92, alkalinity from 0.00 to 189.10mg L-1 de HCO3-1, hardness from 0.00 to 136.00mg L-1 carbonate of calcium, color from 0.0 to 9.0 units PtCo, turbidity from 0.00 to 2.00 FTU of turbidity, sulphate from 0.00 to 55.67mg L-1, sulfide from 0.00 to 0.002mg L-1, chloride from 0.00 to 23.53mg L-1, fluoride de 0.02 a 0.8mg L-1 aluminum from 0.01 to 0.09mg L-1, barium from 0.00 to 0.26mg L-1, calcium from 0.53 to 28.35mg L-1, chromium from 0.00 to 0.01mg L-1, iron from 0.00 to 0.03mg L-1, potassium from 0.39 to 3.27mg L-1, sodium from 0.53 to 97.29mg L-1, magnesium from 0.00 to 9.10mg L-1, manganese from 0.00 to 0.05mg L-1, zinc from 0.00 to 0.03mg L-1, lead from 0.00 to 0.01mg L-1 and lithium from 0.00 to 0.02mg L-1. The elements cadmium, copper and cobalt were below the limits of detection for the analytical methods.

Scientific Electronic Library Online (Portuguese)

6

Transporte de carga em compósitos de polianilina/V2O5/ Charge transportation in polyaniline/V2O5 composites

Huguenin, Fritz; Torresi, Roberto M.
2004-06-01

Resumo em inglês In this work, composites formed from a mixture of V2O5 and polyaniline (PANI) were investigated, for applications as cathode materials for secondary lithium batteries. Electrochemical quartz crystal microbalance (EQCM) data show that charge compensation in the [PANI]0.3V2O5 nanocomposite is achieved predominantly by Li+ migration. However, the charge compensation in the [PANI]V2O5 microcomposite occurs by Li+ and ClO4- transport. Electrochemical Impedance Spectroscopy (EI (mais) S) measurements reveal several benefits of nanohybrid formation, including the achievement of shorter ionic diffusion pathways, the higher diffusion rate of the lithium ion and also the higher electronic conductivity, which are responsible for a synergetic effect of the energy storage properties.

Scientific Electronic Library Online (Portuguese)

7

Síntese e caracterização dos nanocompósitos K0,1(PEO)xMoS2 (X= 0,5; 1,2)/ Synthesis and characterisation of the nanocomposites K0,1(PEO)xMoS2 (x= 0,5; 1,2)

Wypych, Fernando; Adad, Luciana Barreto; Grothe, Mariely Cristina
1998-11-01

Resumo em inglês The reaction of an aqueous solution of poly(ethylene oxide) (peo - mw 100.000) with a neutral aqueous suspension of single layers of MoS2 was studied. The single layers aqueous suspension was prepared by first intercalating lithium (using n-Butyllithium in n-hexane) and reaction of these ternary compound with water under ultrasound stirring. The suspension was washed several times with water until neutral pH. The suspension was mixed with the PEO aqueous solution in the p (mais) resence of KCl. Two single phase compounds were obtained with the expansion of 4,8 and 9,0Å, attributed to the solvation of the intercalated potassium cations with mono and double layers, respectively.

Scientific Electronic Library Online (Portuguese)

8

Processamento de pilhas do tipo botão/ Processing of spent button cells

Silva, Cristiano Nunes da; Afonso, Julio Carlos
2008-01-01

Resumo em inglês This work presents hydrometallurgical routes for recovering valuable elements from spent button cells, based on leaching of internal components with sulfuric acid (Li/MnO2 and Zn-air) or nitric acid (Ag-Zn), at 90 ºC for 2h. Slow evaporation of the leachate crystallized MnSO4.H2O, whereas lithium was partially recovered as LiF. Mercury present in Zn-air and Ag-Zn samples was precipitated as HgS. Silver was recovered as AgCl before mercury precipitation. Zinc and iron wer (mais) e precipitated as hydroxides. The amount of iron varied according to the intensity of the corrosion of the external cell case. Final wastes are neutral and colorless sodium sulfate/nitrate solutions.

Scientific Electronic Library Online (Portuguese)

9

Filmes de óxidos anódicos de nióbio: efeito eletrocrômico e cinética da reação de eletro-intercalação/ Anodic niobium oxide films: electrochromic effect and electrointercalation reaction kinetics

Maranhão, Silvanna L. de Albuquerque; Torresi, Roberto M.
1998-06-01

Resumo em inglês The aim of this work is to study the electrochromism and the reaction kinetics of lithium electrointercalation in anodic niobium oxide films. The oxide grown in an acid environment by application of an alternating potential shows interference colour (iridescence) and when reduced in lithium perclorate/PC solution, the intercalation of Li+ ions and electrons causes a reversible colour change (electrochromism), characterized here by electrochemical and optical measurements. (mais) A model where the reaction kinetics is dominated by diffusion of ionic pairs (Li+, e-) in the oxide film permitted the reproduction of current and absorbance temporal dependence, confirming the relationship between the electrochromic and electrochemical reactions. From the results obtained, a relation was established where the colour change is associated to the reduction of Nb+5 to Nb+4 ions with simultaneous cations injection.

Scientific Electronic Library Online (Portuguese)

10

Avaliação da posição do supercílio por medidas angulares/ Evaluation of eyebrow position using angular measures

Matai, Olívia; Lavezzo, Marcelo Mendes; Schellini, Silvana Artioli; Padovani, Carlos Roberto Pereira; Padovani, Carlos Roberto
2007-02-01

Resumo em português OBJETIVO: Avaliar a posição do supercílio em diferentes idades, utilizando medidas angulares. MÉTODOS: Foram avaliados indivíduos com idade de 4 a 6 anos (Grupo de crianças) e igual ou superior a 50 anos (Grupo de idosos), separados em faixas etárias, avaliando-se a posição do supercílio por meio de imagens digitais, utilizando medidas angulares. As imagens foram tomadas em posição primária do olhar, utilizando filmadora Sony Lithium, e posteriormente transfe (mais) ridas para computador MacIntosh G4 e processadas pelo programa NIH 1,58. Os parâmetros analisados foram: ângulo interno, externo e vertical da cauda do supercílio. As comparações foram entre sexos, faixas etárias e lateralidade. Os resultados obtidos foram submetidos à análise estatística. RESULTADOS: A comparação das medidas angulares mostrou que houve diferença significativa na posição da cauda do supercílio entre os grupos estudados quando comparados dentro do grupo com faixa etária semelhante. Porém, comparando-se crianças e adultos, houve diferença em todos os tipos de ângulos estudados. CONCLUSÕES: A posição do supercílio avaliada por medidas angulares mostrou diferenças entre crianças e idosos, revelando associação positiva com a idade. Resumo em inglês PURPOSE: To evaluate the eyebrow position in children and elderly using angle measurements. METHODS: The eyebrow position was evaluated by digital images in 4 to 6-year-old children (children group) and in patients with 50 years or more (elderly group), separated by age range. The images were taken in the primary gaze position with a Sony Lithium camera and then transferred to a MacIntosh G4 computer and processed by the NIH 1.58 program. The eyebrow position was evaluate (mais) d using angle measures. Comparisons were done according to age, sex and laterality and the data were submitted to statistical analysis. RESULTS: The comparison of the angular measures showed that there was a significant difference in the position of eyebrow position between the studied groups with the same age. But comparing children and elderly there were differences in all performed measurements. CONCLUSION: The eyebrow external angle positions showed differences between children and elderly with a positive association between eyebrow position and age.

Scientific Electronic Library Online (Portuguese)

11

Avaliação comparativa do ritmo de piscar em crianças normais em idade pré-escolar/ Comparative evaluation of healthy preschool children blink

Lavezzo, Marcelo Mendes; Schellini, Silvana Artioli; Padovani, Carlos Roberto
2007-06-01

Resumo em português OBJETIVO: Estabelecer o padrão de normalidade do ritmo de piscar em crianças normais em idade pré-escolar. MÉTODOS: Avaliaram-se 200 crianças de 4 a 6 anos, saudáveis, usando tomada de imagens digitais, nos planos frontal e lateral, em estado de vigília, em posição primária do olhar, estando o objeto de observação localizado na altura da pupila. Para a tomada das imagens foi utilizada uma filmadora Sony Lithium, sendo as mesmas gravadas em fitas 8 mm, transfer (mais) idas para um computador MacIntosh G4 e processadas pelo programa iMovie, estudando-se: o tempo de abertura e o tempo de fechamento palpebral, o tempo de piscar completo e o ritmo de movimentos palpebrais por minuto, durante 3 minutos. Os resultados foram avaliados por estatística descritiva e gráfico de linhas. RESULTADOS: O piscar completo foi mais freqüente que o incompleto. O ritmo do piscar completo aumenta com o aumento da idade. Para o piscar incompleto, os valores foram semelhantes em todas as idades avaliadas. O tempo de fechamento e de abertura palpebral e o tempo de piscar completo foram semelhantes em meninos e meninas. O tempo de fechamento foi mais lento que o tempo de abertura palpebral. CONCLUSÕES: O ritmo de piscar completo aumenta com a idade. Os tempos de fechamento e de abertura palpebral e o tempo de piscar completo foram semelhantes em ambos os sexos, em todas as idades estudadas, sendo o fechamento mais lento que a abertura palpebral. Resumo em inglês PURPOSE: To evaluate spontaneous blink activity in the primary eye position in normal preschool children. METHODS: Two hundred normal children aged 4 to 6 years were prospectively evaluated. They were digitally videotaped in a standard setting, taking the images on frontal and lateral plans, during the vigil state, in the primary eye position. The object of observation was located at the same level of the pupil. A Sony Lithium camera was used. The images were recorded on (mais) 8 mm tapes and transferred to a personal computer (MacIntosh G4) and processed with the iMovie software. Opening, closure and total blink times were measured using frame scale. The eyelid movement rhythm per minute was also evaluated, during three minutes. The data were submitted to statistical analysis. RESULTS: The complete eye blink was more frequently observed than the incomplete eye blink. The blink rate increased with age. The incomplete blink rate was the same for all the evaluated ages. The eyelid opening and closing times and the complete blink time were similar for both sexes, during all evaluation moments. There were no differences between genders regarding eye blink. The closing eyelid time was slower than the opening eyelid time. CONCLUSIONS: The complete blink rate increases with age. The closing and the opening eyelid times and the complete blink were similar for both sexes in all evaluated ages and the opening time is faster than the closing time.

Scientific Electronic Library Online (Portuguese)

12

Alterações palpebrais após a idade de 50 anos/ Eyelid alterations after the age of 50 years

Siqueira, Michael; Joaquim, Andrei; Schellini, Silvana Artioli; Padovani, Carlos Roberto; Cruz, Antonio Augusto Velasco e
2005-06-01

Resumo em português OBJETIVO: Avaliar quantitativamente as mudanças da posição palpebral e as medidas da fenda palpebral de indivíduos acima dos 50 anos. MÉTODOS: Estudo observacional, tendo sido avaliados 325 indivíduos, com idade acima de 50 anos, segundo distância intercantal, largura e altura da fenda palpebral, ângulo palpebral externo e interno, distância entre o reflexo pupilar e a margem da pálpebra superior (distância reflexo-margem) e a área total da fenda palpebral. Ut (mais) ilizou-se filmadora Sony Lithium para obtenção das imagens digitais, com o indivíduo fixando um objeto a 1 metro de distância, sendo as imagens transferidas posteriormente para computador McIntosh G4 e processadas pelo programa NIH 1.58. Os dados foram submetidos à análise estatística. RESULTADOS: Os participantes apresentavam dermatocálase (96,5%), ptose do supercílio (60,8%), prolapso de gordura orbital (50,0%) ou ptose palpebral (39,1%). As alterações foram bilaterais em 68,8% dos indivíduos. A distância intercantal aumentou com a idade; a largura da fenda palpebral, a distância reflexo-margem e a medida do ângulo externo diminuíram nos mais idosos. As diferenças foram mais significativas quando os olhos foram estudados separadamente. CONCLUSÃO: A distância intercantal aumenta, ao passo que a largura da fenda palpebral, a distância reflexo-margem e a área total da fenda palpebral diminuem com o aumento da idade. Resumo em inglês PURPOSE: To quantify the palpebral alterations occurring in subjects after the age of 50 years. METHODS: An observational study was done with 325 subjects older than 50 years. The data comprised measurements of intercantal distance, palpebral fissure length and height, external and internal eyelid angles, margin reflex distance (MRD) and total palpebral fissure area. Digital images were obtained with a Sony Lithium movie camera at the frontal view in ocular primary positi (mais) on, with the object of observation being located at the height of the pupil. The images were saved on tape, transferred to a McIntosh G4 computer and processed with the NIH 1.58 program. The data were submitted to statistical analysis. RESULTS: The subjects presented dermochalasis (96.5%), eyebrow ptosis (60.8%), orbital fat prolapse (50.0%) or eyelid ptosis (39.1%). The alterations were bilateral in 68.8% of the subjects. The intercantal distance was higher with age; the eyelid fissure length, the margin reflex distance and the external angle decreased in the elderly. The differences were more important on evaluating each eye separately. CONCLUSION: Intercantal distance increase and palpebral fissure length, margin reflex distance and total eyelid area decrease with age.

Scientific Electronic Library Online (Portuguese)