Sample records for ion selective electrode analysis
from WorldWideScience.org

Sample records 1 - 3 shown.



1

Determinação de ascarel em óleo isolante de transformadores/ Ascarel determination in insulating oil of transformers

Antonello, Izoldir; Humeres, Eduardo; Souza, Ivan Gonçalves de; Debacher, Nito Angelo; Martins, Alexandre Rios
2007-06-01

Resumo em inglês The contamination level of silicon oil used as insulation liquid in high-voltage transformers by ascarel (PCBs) is above those permitted by the Brazilian law. Thus new techniques able to detect ascarel, with low operational costs, are very attractive. The present work proposes an analysis of the contamination levels of silicon oil using the following techniques: naphthalene anion radical reaction for ascarel dechlorination; and potentiometry with an ion-selective electrod (mais) e for chloride ion determination. The data obtained with the proposed methodology agree well with those from the official methodology, (method IEC 61619).

Scientific Electronic Library Online (Portuguese)

2

Cálcio ionizado no soro: estimativa do intervalo de referência e condições de coleta/ Serum ionized calcium: reference interval estimation and blood collection condictions

Andriolo, Adagmar; Moreira, Silvia Regina; Silva, Luciene Alves; Carvalho, Aluizio Barbosa de; Vieira, José Gilberto H.; Ghiringhello, Maria Teresa; Juliano, Yara
2004-04-01

Resumo em português INTRODUÇÃO: A dosagem de cálcio ionizado, em nosso meio, tem se tornado freqüente em substituição à de cálcio total, com vantagens, por ser a fração fisiologicamente ativa e pelo desenvolvimento de metodologia robusta e com relação custo/benefício adequada. Seu uso implica a necessidade de definição de intervalos de referência. OBJETIVO: Estimar o intervalo de referência para o cálcio ionizado sérico e avaliar interferências do tempo de permanência do (mais) torniquete e do resfriamento da amostra. MATERIAL E MÉTODO: Para a estimativa do intervalo de referência, foram incluídos os resultados de 11.320 dosagens consecutivas de cálcio ionizado realizadas de janeiro de 2000 a novembro de 2002; para avaliar o efeito da refrigeração foram realizadas 16 coletas em duplicata, sendo que um dos tubos foi colocado em banho de gelo imediatamente após a coleta e o outro foi mantido à temperatura ambiente; para avaliar o efeito do tempo de garroteamento, em seis voluntários foi realizada a coleta em um dos braços imediatamente após a aplicação do torniquete e, no outro braço, após 3 minutos de garroteamento. O sangue foi colhido em tubos sem ar, contendo gel separador, e centrifugado em até 30 minutos após a coleta. Todas as dosagens foram realizadas em até 4 horas após a centrifugação por eletrodo íon-seletivo. RESULTADOS: Considerando-se os 95% centrais dos dados, os limites inferior e superior foram 1,11mmol/l (intervalo de confiança de 90%: 1,1 a 1,11mmol/l) e 1,4mmol/l (intervalo de confiança de 90%: 1,39 a 1,41mmol/l), respectivamente. Não foram detectadas diferenças significativas nos resultados das amostras com e sem refrigeração e entre as amostras coletadas com menos de um minuto e com três minutos de garroteamento. Resumo em inglês INTRODUCTION: The ionized serum calcium determination has become frequent replacing the total calcium with advantages: it is the physiologically active fraction, and the availability of robust methodology with favorable cost/benefice ratio. The use of this methodology implies in reference interval estimation. OBJECTIVE: To estimate the reference interval for serum ionized calcium, and to evaluate interferences in tourniquet time application, and interferences in sample re (mais) frigeration before analysis. MATERIAL AND METHOD: to estimate the reference interval we included the results of 11,320 consecutive calcium ionized determinations accomplished from January 2000 to November 2002; in order to evaluate the effect of sample refrigeration, 16 samples were collected in duplicate, so that one tube was placed in ice bath and the other was maintained in room temperature. To evaluate the effect of tourniquet application time, we collected blood samples from one arm of 6 normal subjects, immediately after, and from the other arm, after 3 minutes of the tourniquet application. The blood was collected in evacuated tubes with gel separator and centrifuged up to 30 minutes after collection. All determinations were performed up to 4 hours after the centrifugation by ion-selective electrode. RESULTS: regarding to the central 95% data distribution, the inferior and superior limits were, respectively, 1.11 (confidence interval of 90%: 1.1 to 1.11) and 1.4mmol/l (confidence interval of 90%: 1.39 to 1.41). No significant differences were detected between results with and without refrigeration and between samples with less than 1 and after 3 minutes of tourniquet application.

Scientific Electronic Library Online (Portuguese)

3

Construção e avaliação de um eletrodo tubular sensível ao íon hidrogênio como detector em sistemas de análise em fluxo/ Construction and evaluation of a tubular ion-selective electrode for hidrogen ion as a detector in flow analysis

Martelli, Patrícia B.; Reis, Boaventura F.; Zagatto, Elias A.G.; Lima, José L.F.C.; Lapa, Rui A.
1998-04-01

Resumo em inglês The construction of a tubular hydrogen ion-selective potentiometric electrode without inner reference solution, based on the tridodecylamine (TDDA) ionophore, and its evaluation in a flow system are described. TDDA was dissolved in 2-nitrophenyl octyl ether, dispersed in a PVC membrane and applied directly to a conducting support which consisted of an epoxy resin and graphite mixture. The electrode was designed with a tubular geometry to effort facilities to be coupled as (mais) part of a flow injection network. The main working characteristics such as response time, linear pH range, selectivity and life time were evaluated and compared with those obtained which a conventionally shaped electrode based on the same sensor. The electrode showed a slope of 51-52 mV dec-1 within a linear pH range from 4.0 up to 12.0.

Scientific Electronic Library Online (Portuguese)