Sample records for heaters
from WorldWideScience.org

Sample records 1 - 5 shown.



1

Potencial de redução do consumo de energia elétrica pela utilização de aquecedores solares no Estado de Goiás/ Reduction potential on electric power consumption using solar heaters at State of Goiás, Brazil

Oliveira, Luiz F. C. de; Ferreira, Regis de C.; Almeida, Rogério de A.; Lobato, Engler J. V.; Medeiros, Antônio M. de M.
2008-09-01

Resumo em português O presente trabalho analisa a viabilidade técnica da redução do uso de energia elétrica pela substituição dos chuveiros elétricos por aquecedores solares e apresenta uma análise da redução do custo mensal de energia elétrica para os diferentes municípios de Goiás. Por meio do processamento de dados climatológicos e com o auxílio do aplicativo de informações geográficas SPRING®, foram calculados os valores de irradiâncias (MJ m-2 anual-1) e do número d (mais) e horas anuais de brilho solar sobre a superfície da Terra e no topo da atmosfera, respectivamente, para os municípios do Estado de Goiás. Com base em dados censitários, calcularam-se o consumo médio de energia elétrica mensal por domicílio (kWh mês-1) e o total anual (kWh ano-1). Analisou-se a redução do custo mensal de energia elétrica por domicílio pela substituição de chuveiros elétricos com diferentes potências comerciais por aquecedores solares. Analisaram-se, ainda, a redução da vazão que passa na turbina (m³ s-1) da principal usina hidrelétrica de Goiás e a relação entre a redução da potência total anual (kW) e a potência gerada por essa usina (kW). Procedeu-se, finalmente, à análise econômica, avaliando-se a relação custo/benefício da substituição proposta. Os resultados mostraram redução média mensal da conta de energia de R$ 36,92 e média de 13 meses para o retorno do capital investido. Pôde-se concluir pela viabilidade técnica, econômica e ambiental da substituição dos chuveiros elétricos pelos sistemas aquecedores/reservatórios térmicos. Resumo em inglês A technical viability analysis on reduction of the electric power consumption by the substitution of electric showers by the adoption of solar heaters and analysis of monthly savings costs for the municipalities of State of Goiás (Brazil) were performed. Using processing of local weather data, aided by the geographical information applicative SPRING, irradiancy values (MJ m-2 year-1) and the number of annual hours of solar shine on earth surface and on the top of the atm (mais) osphere, were calculated. Based on census data, the average monthly electric power consumption per household (kWh month-1) and the total one per year (kWh year-1), and the reduction on the monthly cost per household were estimated. Analyzed is also the reduction of flow that passes in turbine (m³ s-1) from the main hydroelectric power plant of State of Goiás and on the relationship between the total annual power (kW) and that one generated by same plant (kW) were predicted. At last, economic analysis of the results for the proposed substitution showed an average monthly diminution of about R$ 36.92 (US$ 17.00) on the energy bill, per household and an average term of 13 months for the return of the invested capital. One concluded by the technical, economical and environmental viability for the substitution of electric showers by thermal heaters/reservoirs systems.

Scientific Electronic Library Online (Portuguese)

2

Avaliação do desempenho de um aquecedor para aves adaptado para utilizar biogás como combustível/ Birds heater adaptation and performance using biogas as fuel

Santos, Tânia M. B.; Lucas Júnior, Jorge de; Silva, Fábio M. da
2007-12-01

Resumo em português Desenvolveu-se ensaio para avaliar a adaptação (diâmetro do injetor) e o desempenho (consumo e eficiência de aquecimento) de um aquecedor tipo campânula, adaptado para queimar biogás. Foi testado um aquecedor comum que, queimando gás liquefeito de petróleo (GLP), opera à baixa pressão (28 cm.c.a.), com capacidade calorífica de 5.024 kJ h-1 e recomendado para 500 aves. O aquecedor foi avaliado com o combustível original (GLP), sem qualquer modificação no inje (mais) tor de gás, e após adaptação para o funcionamento a biogás. Na adaptação, foi mantida a mesma grelha do queimador principal, aumentando-se a perfuração do injetor para permitir o funcionamento e a avaliação. Foram avaliados cinco injetores com perfurações de 1,0053; 1,5080; 1,5708; 1,7672 e 1,980 mm². Também se variaram as pressões do biogás na entrada do aquecedor de 10; 12; 15; 17 e 20 cm de coluna d'água (cm.c.a.). Os resultados indicaram que as expressões de cálculo teórico e parâmetros propostos na bibliografia podem ser utilizados com segurança na adaptação de aquecedores do tipo campânula utilizados em aviários; que a adaptação é de simples execução, indicando a viabilidade da utilização dos aquecedores já existentes em granjas e no mercado, e que as temperaturas do ar foram semelhantes às obtidas com o combustível original (GLP). Resumo em inglês It was carried out a trial to evaluate the adaptation (injector diameter) and performance (biogas consumption and heating efficiency) of a heating adapted to burn biogas. It was tried a common heater, burning liquefied petroleum gas (LPG), operating with low gas pressure (28 cm water column), with calorific capacity of 5024 kJ/h and recommended for 500 birds. The heater was evaluated with the original fuel (LPG) without any modification in the gas injector and after adapt (mais) ing to biogas burning. Five injectors were evaluated with drillings of 1,0053; 1,5080; 1,5708; 1,7672 and 1,980 mm2. It also was varied the biogas pressures in the heater entrance of 10, 12, 15, 17 and 20 cm of water column. Results showed that expressions for theoretical calculation and proposed parameters in the literature can be used for aviaries heaters adaptation. The adaptation is simple, indicating the viability for utilization of existing heaters in farms and in the market. Air temperatures were similar to the obtained with the original fuel (LPG).

Scientific Electronic Library Online (Portuguese)

3

Lipídeos na Alimentação de Alevinos Revertidos de Tilápia do Nilo (Oreochromis niloticus, L.)/ Fat on the Reverted Nile Tilapia (Oreochromis niloticus) Fingerlings Feeding

Meurer, Fábio; Hayashi, Carmino; Boscolo, Wilson Rogério; Soares, Claudemir Martins
2002-01-01

Resumo em português Objetivando avaliar os efeitos de níveis crescentes de lipídeos na ração sobre desempenho, velocidade de trânsito do alimento, consumo de ração e gordura corporal, foram utilizados 168 alevinos de tilápia do Nilo, revertidos, com peso médio de 1,24 ± 0,03g e comprimento médio de 4,10 ± 0,30 cm, distribuídos em 24 aquários, de 50 L de volume útil, em um delineamento inteiramente casualizado com seis tratamentos e quatro repetições, considerando-se um aquá (mais) rio com sete animais como unidade experimental, por um período de 40 dias. A temperatura foi mantida em 27,2 ± 0,6ºC por aquecedores de 100 W com termostato e aeração constante. As rações foram formuladas sendo isoprotéicas, isoenergéticas e isoaminoacídicas para lisina e metionina mais cistina, variando quanto ao nível de lipídeos (3,0; 4,8; 6,6; 8,4; 10;2; e 12,0%). Foram avaliados o efeito do nível de lipídeos sobre as médias do ganho de peso (GP), conversão alimentar (CA), taxa de eficiência protéica (TE), consumo de ração (CR), velocidade de passagem de alimento (VP) e gordura corporal (GC). O GP, TE, CA diminuíram linearmente com o aumento do nível de lipídeos na ração, enquanto que a GC aumentou, o CR não apresentou diferença entre os tratamentos; a VP apresentou um comportamento quadrático com ponto de mínimo em 6,0% de gordura na ração. Como conclusão recomenda-se o uso de 3,0% de lipídeos na ração de alevinos de tilápia do Nilo e ressalta-se a melhor utilização do amido como fonte de energia em relação à gordura para esta espécie. Resumo em inglês Aiming to evaluate the effect of increasing levels of fat in the ration on performance, speed of food pass, consummates of ration and corporal fat, it were used 168 Nile tilapia fingerlings, reverted, with average weight of 1.24 ± 0,03g and average size of 4.10 ± 0.30 cm, allotted to 24 aquariums, of 50 L of useful volume, in a completely randomized design with six treatments and four replicates, where the aquarium with seven animals was considered experimental unit, fo (mais) r a period of 40 days. The temperature was kept in 27.2 ± 0.6ºC for heaters of 100W with thermostat and constant aeration. Diets were formulated to be isonitrogen, isoenergy and isoamino acidic for lysine and cystine + methionine, varying how much to the level of fat (3.0, 4.8, 6.6, 8.4, 10.2, and 12.0%). They had been evaluated the effect of the level of fat on the averages of the weight gain (GP), feed conversion (CA), tax of protein efficiency (TE), consumption of ration (CR), speed of food pass (VP) and corporal fat (GC). The GP, TE, CA had decreased linearly as the dietary level of fat increased, while GC increased, the CR did not present difference between the treatments, the VP presented a quadratic effect with point of minimum in 6.0% of fat in the ration. To reverted Nile tilapia fingerlings it is recommend 3.0% as fat level in the diet and was show a better starch utilization like energy source than fat in this specie.

Scientific Electronic Library Online (Portuguese)

4

Estimativa da radiação solar global diária em função do potencial de energia solar na superfície do solo/ Estimation of daily global solar radiation as a function of the solar energy potential at soil surface

Pereira, André Belmont; Vrisman, Augusto Leandro; Galvani, Emerson
2002-06-01

Resumo em português A radiação solar recebida na superfície do solo, além de sua relevância a diversas atividades humanas diárias, desempenha um papel importante no crescimento e desenvolvimento de plantas. Este trabalho teve por objetivo desenvolver e aferir um modelo de estimativa da densidade de fluxo de radiação solar global, em função do potencial de energia solar à superfície, no município de Ponta Grossa, PR, Brasil (latitude 25º13' S, longitude 50º03' W, altitude 880 m (mais) ). Os valores estimados do potencial de energia solar obtidos em função de apenas uma medida realizada na passagem meridiana do sol foram confrontados com os valores medidos por um actinógrafo de placa bimetálica de Robitzsch para aqueles dias que apresentaram razão de insolação superior a 0,85. Este conjunto de dados foi submetido a uma análise de regressão linear simples, obtendo-se bom ajuste entre valores observados e calculados. Foi utilizado o método baseado no potencial de energia solar à superfície para estimativa dos coeficientes a e b da equação de Angström para a localidade em questão. A metodologia foi eficiente para quantificar a densidade de fluxo de radiação solar global, com rapidez e simplicidade, bem como revelaram que o critério de estimativa do potencial de energia solar gerou valores equivalentes aqueles obtidos pela metodologia clássica de Angström. O conhecimento do potencial de energia solar disponível e da densidade de fluxo de radiação global é de suma importância na estimativa da demanda máxima de evaporação, do consumo hídrico de culturas irrigadas e para o dimensionamento de artifícios de engenharia solar, tais como secadores, aquecedores, fogões solares, refrigeradores etc. Resumo em inglês The solar radiation received at the surface of the earth, apart from its relevance to several daily human activities, plays an important role in the growth and development of plants. The aim of the current work was to develop and gauge an estimation model for the evaluation of the global solar radiation flux density as a function of the solar energy potential at soil surface. Radiometric data were collected at Ponta Grossa, PR, Brazil (latitude 25º13' S, longitude 50º03 (mais) ' W, altitude 880 m). Estimated values of solar energy potential obtained as a function of only one measurement taken at solar noon time were confronted with those measured by a Robitzsch bimetalic actinograph, for days that presented insolation ratios higher than 0.85. This data set was submitted to a simple linear regression analysis, having been obtained a good adjustment between observed and calculated values. For the estimation of the coefficients a and b of Angström's equation, the method based on the solar energy potential at soil surface was used for the site under study. The methodology was efficient to assess the coefficients, aiming at the determination of the global solar radiation flux density, whith quickness and simplicity, having also found out that the criterium for the estimation of the solar energy potential is equivalent to that of the classical methodology of Angström. Knowledge of the available solar energy potential and global solar radiation flux density is of great importance for the estimation of the maximum atmospheric evaporative demand, of water consumption by irrigated crops, and also for building solar engineering equipment, such as driers, heaters, solar ovens, refrigerators, etc.

Scientific Electronic Library Online (Portuguese)

5

Utilização de sistemas de aquecimento por ar e por água quente em estufas localizadas em zonas mediterrânicas/ Utilisation of air and pipe heating systems in Mediterranean greenhouses

Afonso, J.; Baptista, F.; Cruz, V. Fitas da; Garcia, J.L.
2007-01-01

Resumo em português Um dos principais objectivos da produção em estufa é a obtenção de plantas, em quantidade e qualidade, que de outro modo não seria possível devido às condições adversas do meio exterior. No entanto, de modo a obter no interior da estufa as condições de temperatura e humidade adequadas é normalmente necessário recorrer a técnicas de condicionamento ambiental, como sejam, a ventilação e o aquecimento. Neste trabalho pretendeu-se estudar a influência de dif (mais) erentes sistemas de aquecimento, por ar quente e por água quente, nas condições de ambiência no interior de uma estufa localizada numa zona Mediterrânica continental. Além disso, pretendeuse também comparar o efeito destes sistemas de aquecimento na ocorrência de condensação. Este é um aspecto de grande importância já que a condensação pode ser um factor favorável à proliferação de determinadas doenças criptogâmicas, responsáveis por avultadas perdas de produção. O trabalho experimental foi realizado numa estufa localizada em Madrid na Escola Técnica Superior de Engenheiros Agrónomos. A estufa era multitúnel tendo o tecto a forma elipsoidal. A área da estufa era 132 m ² e o material de cobertura metacrilato com 3 mm de espessura. O sistema de ventilação consistia em aberturas contínuas laterais e zenitais. Esta estufa estava equipada com dois sistemas de aquecimento, termoventiladores (ar quente) e solo radiante (água quente). Foram recolhidos dados relativos à temperatura e humidade relativa do ar no interior e no exterior, bem como da ocorrência de condensação na parte interna da cobertura da estufa. Todos os dados foram registrados com intervalos de 5 minutos, durante vários dias. Verificou-se que a humidade relativa e os períodos em que ocorreu condensação são bastante menores quando se utilizou o aquecimento por ar quente. Ambos os sistemas foram comparados relativamente ao consumo energético. Para as mesmas condições climáticas exteriores, o sistema de aquecimento por água quente apresentou maior consumo energético que o sistema de aquecimento por ar quente, nas condições testadas. Resumo em inglês One of the main objectives of the greenhouse production is to obtain a good performance of the crops, which would not be possible outside due to adverse conditions of the environment. However, to achieve suitable internal air temperature and humidity it is usually necessary to use environmental control techniques, as ventilation or heating. The objectives of this work were: 1. to study the effect of the different heating systems, pipe and air, in the climatic conditions i (mais) n a Mediterranean greenhouse and 2. to study the influence of these different heating systems on the occurrence of condensation. External and internal climatic data were collected as the occurrence of condensation on internal surface of the cover material. All data were registered in a Data Logger each 5 minutes, during several days. With air heaters, inside relative humidity was lower comparing to pipe heating. Both strategies were compared concerning the energy consumption. For the same outside conditions, pipe heating presented higher levels of energy consumption than air heaters. With air heaters, the condensation rate on the inner surface of the cover was strongly reduced.

Scientific Electronic Library Online (Portuguese)