Sample records for fluorine 14
from WorldWideScience.org

Sample records 1 - 6 shown.



1

Influência do complexo flúor-xilitol no controle da placa dentária e do sangramento gengival em pacientes herbiátricos com aparelho ortodôntico fixo/ Influence of fluorine-xylitol complex in the dental plaque and gingival bleeding control in herbiatric patients with fixed orthodontic brace

Elias, Fabíola; Pinzan, Arnaldo; Bastos, José Roberto de Magalhães
2006-10-01

Resumo em português OBJETIVO: avaliar os efeitos de um dentifrício contendo flúor/xilitol na redução da adesão da placa à estrutura dentária, bem como no índice de sangramento gengival, em portadores de aparelho ortodôntico fixo. METODOLOGIA: foram avaliados 22 jovens, com idade entre 14 e 17 anos. Após a quantificação inicial dos índices, os jovens receberam instruções de escovação e começaram a utilizar somente os dentifrícios da pesquisa. Houve uma divisão aleatória d (mais) a amostra em dois grupos (A e B). Na primeira semana todos utilizaram um dentifrício padrão e a partir da segunda semana os jovens do grupo A receberam um dentifrício contendo flúor, enquanto os do grupo B receberam um dentifrício contendo o complexo flúor-xilitol, que utilizaram durante vinte e oito dias, quando foram novamente avaliados (T1). Para a segunda fase (T2) houve inversão dos dentifrícios. RESULTADOS: foram comparados os resultados intra-grupo e nos dois grupos houve redução estatisticamente significante entre as fases inicial e T1, inicial e T2 e entre T1 e T2. Já na comparação entre os grupos não houve diferença estatisticamente significante entre eles, embora o dentifrício contendo flúor/xilitol tenha proporcionado uma porcentagem de redução do índice de sangramento gengival maior que o dentifrício contendo apenas o fluoreto de sódio, principalmente entre as fases inicial e T2, onde a redução no grupo A foi de 90,13% e no grupo B foi de 78,84%. CONCLUSÃO: a utilização de dentifrícios contendo flúor e xilitol, associada à instrução e motivação, parece ser um recurso bastante promissor para a manutenção da saúde bucal nos pacientes ortodônticos. Resumo em inglês AIM: to evaluate the effects of a dentifrice containing fluorine/xylitol in the reduction of the adhesion of the plaque to the dental structure, as well as in the gingival bleeding index in patients who had orthodontic braces. METHODS: 22 teenagers, in between 14 and 17 years old were evaluated. After the initial quantification of the indexes, they received instructions of brushing and started to use only the dentifrices from the research. There was a random division of t (mais) he sample into two groups, A and B. In the first week, they all used a standard dentifrice and since the second week the teenagers from group A received a dentifrice with fluorine, while the ones from group B received a dentifrice containing the fluorine-xylitol complex, using for 28 days, when they were evaluated again (T1). There was an inversion of dentifrices for second phase. RESULTS: the results were compared intra-groups and in both groups there was a statistically significant reduction between phases initial and T1, initial and T2 and between T1 and T2. However, comparing the groups, there was no statistically significant difference between them, though the dentifrice containing fluorine/ xylitol provided a percentage of reduction of gingival bleeding index bigger than the one containing only sodium fluoride, specially between phases initial and T2, where reduction in group A was 90.13% and in group B was 78.84%. CONCLUSION: the utilization of dentifrice containing fluorine and xylitol, associated to instruction and motivation, seems to be a promising resource for maintenance of oral health in orthodontic patients.

Scientific Electronic Library Online (Portuguese)

2

Estudos histológico-morfométricos e microrradiográficos de costelas de bovinos suplementados com fosfato de rocha/ Morphologic-morphometrical and microradiographical studies on ribs of cattle supplemented with rock phosphate

Pilati, Célso; Rosa, Ivan V.; Dayrell, Milton S.; Döbereiner, Jürgen; Dämmrich, Klaus
1997-07-01

Resumo em português O objetivo do presente trabalho foi o de avaliar, através de técnicas especializadas, as possíveis alterações ósseas produzidas em bovinos em decorrência da ingestão prolongada de diferentes níveis de flúor contido no fosfato de rocha de Tapira utilizado como fonte suplementar de fósforo. No primeiro experimento bovinos confinados ingeriram, durante 6 meses, quantidades variáveis (63 e 128g/dia) de fosfato de Tapira contendo 1.3% de flúor. No segundo experime (mais) nto, bovinos em pastos de Brachiaria decumbens ingeriram, durante 33 meses, misturas minerais contendo diferentes níveis de fosfato de rocha de Tapira. No terceiro experimento, novilhas com idade inicial média de 14 meses ingeriram mistura mineral com fosfato de Tapira até a quinta lactação inclusivamente. Através de exames histológicos, morfométricos e microrradiográficos das amostras de costelas, não se observaram alterações da normalidade óssea, bem como não foram registradas diferenças entre amostras provenientes de diferentes tratamentos. Tais achados permitem inferir que, do ponto de vista de alterações ósseas, o fosfato de rocha de Tapira pode ser utilizado como fonte suplementar de fósforo para bovinos, nas dosagens, períodos e manejos alimentares estudados, sem risco de produzir alterações patológicas nos esqueleto dos animais. Resumo em inglês The present study was conducted to evaluate possible bone changes in cattle due to the ingestion of different levels of fluorine from rock phosphate used as a phophorus supplement. The bone material studied were ribs collected from cattle of three experiments where Tapira rock phosphate was used at different levels and during different periods as a partial or sole source of supplementary phosphorus. In the first experiment feedlot cattle ingested during a 6 month period 6 (mais) 3 and 128g/day of Tapira rock phosphate containing 1.3% fluorine. In the second experiment cattle maintained in Brachiaria decumbens pastures during 33 months ingested several levels of Tapira rock phosphate in the mineral mixtures. In the third experiment heifers averaging 14 months of age ingested a mineral supplement with Tapira rock phosphate until the 5th lactation period. Careful examination of the rib samples by histological, morphometric and microradiographic techniques revealed no abnormalities which could be related to fluorine ingestion, neither any differences among tretaments regarding the bone structure. These findings support the conclusion that, as far as bone alterations are concerned, Tapira rock phosphate could be used as a source of phosphorus for cattle under the conditions described in the experiments, a practice which would markedly reduce the cost of phosphorus supplementation.

Scientific Electronic Library Online (Portuguese)

3

Valor do FDG[18F]-PET/TC como preditor de câncer em nódulo pulmonar solitário/ Value of [18F]-FDG-PET/CT as a predictor of cancer in solitary pulmonary nodule

Martins, Rafael de Castro; Almeida, Sérgio Altino de; Siciliano, Antônio Alexandre de Oliveira; Landesmann, Maria Carolina Pinheiro Pessoa; Silva, Fabrício Braga da; Franco, Carlos Alberto de Barros; Fonseca, Lea Mirian Barbosa da
2008-07-01

Resumo em português OBJETIVO: Determinar a acurácia diagnóstica da positron emission tomography (tomografia por emissão de pósitrons)/tomografia computadorizada (PET/TC) com deoxiglicose marcada com flúor-18, conhecida como fluorodeoxiglicose (FDG[18F]), na avaliação de nódulo pulmonar solitário (NPS). MÉTODOS: Análise prospectiva de 53 pacientes consecutivos que realizaram PET/TC para avaliação de NPS, entre março de 2005 e maio de 2007. Destes 32 preencheram os critérios de (mais) inclusão. As lesões foram avaliadas quanto a sua localização e tamanho, grau de captação do radiofármaco e o standardized uptake value (SUV, valor padronizado de captação) máximo das lesões. Os achados dos estudos de FDG-PET/TC foram correlacionados com outros preditores de malignidade (idade, sexo, tabagismo, tamanho e localização do nódulo). O diagnóstico definitivo foi estabelecido por confirmação histopatológica ou acompanhamento clínico-radiológico por um período mínimo de um ano. RESULTADOS: Encontrados 14 NPS malignos. Após análise da curva ROC, o SUV de 2,5 foi considerado o melhor ponto de corte que identificou corretamente 13 dos 14 NPS malignos. Os resultados abaixo deste ponto de corte mostraram um exame falso positivo para neoplasia num total de 14. O método semiquantitativo apresentou sensibilidade de 92,9%, especificidade de 72,2%, valor preditivo positivo de 72,2%, valor preditivo negativo de 92,9% e acurácia de 81,2%. Na análise multivariada, apenas a localização do nódulo nos lobos superiores (p = 0,048) e o SUV (p = 0,007) demonstraram significância estatística para malignidade no NPS. CONCLUSÕES: Os dados do estudo mostram que o SUV da FDG[18F] é um bom preditor de neoplasia em nódulos pulmonares e com alto valor preditivo negativo, o que oferece grande segurança em afastar presença de malignidade, indicando sua importância na abordagem diagnóstica do nódulo pulmonar. Resumo em inglês OBJECTIVE: To determine the diagnostic accuracy of positron emission tomography/computed tomography (PET/CT) using fluorine-18-deoxyglucose ([18F]-FDG) for the evaluation of a solitary pulmonary nodule (SPN). METHODS: Prospective analysis of 53 consecutive patients submitted to PET/CT between March 2005 and May 2007 for the evaluation of an SPN. Of those, 32 met the criteria for inclusion in the present study. The lesions were evaluated for location, size, radiotracer upt (mais) ake and maximum standardized uptake value (SUV). The FDG-PET/TC results were correlated with other predictors of malignance (age, gender, smoking status, nodule size and nodule location). The definitive diagnosis was established through histopathology or through clinical/radiological follow-up for at least one year. RESULTS: Fourteen malignant SPNs were found. Through analysis of the ROC curve, we established an SUV of 2.5 as the most appropriate cut-off point, since it correctly identified 13 of the 14 malignant SPNs. The results below that point revealed one false positive for neoplasia out of a total of 14. The semiquantitative method presented a sensitivity of 92.9%, specificity of 72.2%, positive predictive value of 72.2%, negative predictive value of 92.9% and accuracy of 81.2%. The multivariate analysis showed a statistically significant association with SPN malignancy only for nodule location in the upper lobes (p = 0.048) and SUV (p = 0.07). CONCLUSIONS: The results obtained suggest that the SUV of [18F]-FDG is a useful predictor of neoplasia in SPN, with a high negative predictive value, which allows malignancy to be safely ruled out, showing its relevance in the diagnostic approach to pulmonary nodules.

Scientific Electronic Library Online (Portuguese)

4

Valor diagnóstico da tomografia por emissão de pósitrons / tomografia computadorizada (PET-CT) com flúor-18 fluordeoxiglicose (FDG-18F) em pacientes com carcinoma diferenciado da tireóide, níveis séricos de tireoglobulina elevados e pesquisa de corpo inteiro com iodo negativa/ Diagnostic value of positron emission tomography / computed tomography with fluorine-18 fluordeoxyglucose in patients with differentiated thyroid gland carcinoma, high thyroglobulin serum levels and negative iodine whole body scan

Yamaga, Lilian Yuri Itaya; Cunha, Marcelo Livorsi da; Wagner, Jairo; Thom, Annelise Fischer; Daniel, Mauro Miguel; Funari, Marcelo B. de Gusmão
2007-06-01

Resumo em português OBJETIVO: Avaliar o papel da PET-CT com FDG-18F na detecção de recidiva e/ou metástase de carcinoma diferenciado da tireóide (CDT) em pacientes com níveis elevados de tireoglobulina (TG) e PCI negativa. PACIENTES E MÉTODO: Os achados da PET-CT de 25 pacientes foram comparados com a avaliação histopatológica e os métodos convencionais de imagem (MC). RESULTADOS: A PET-CT foi positiva em 16 pacientes com resultado verdadeiro-positivo em 14 e falso-positivo em 2 ca (mais) sos (valor preditivo positivo 87,5%). Nove pacientes tiveram PET-CT negativa; dois evoluíram com níveis indetectáveis de TG. Doença residual foi observada na PCI pós-dose terapêutica de uma paciente. Seis pacientes não apresentaram evidências de tumor durante o seguimento (média 16 meses). PET-CT foi concordante com MC em 52%, parcialmente concordante em 12% e discordante (6 falso-negativos e 3 falso-positivos dos MC) em 36%. Foi observada uma tendência de aumento da proporção de PET-CT positiva com o aumento de TG. CONCLUSÃO: A PET-CT com FDG-18F é útil na detecção de recidiva e/ou metástases de CDT com níveis de TG elevados mas PCI negativa. Apresenta alto valor preditivo positivo e é superior aos MC, sendo mais efetiva quanto maior o nível de TG. Resumo em inglês PURPOSE: To evaluate the role of PET-CT with FDG-18F in the detection of recurrence and/or metastasis of differentiated thyroid carcinoma (DTC) in patients with elevated levels of thyroglobulin (TG) and negative whole body scan (WBS). PATIENTS AND METHOD: PET-CT findings of 25 patients were compared to histopathology evaluation and conventional imaging (CI). RESULTS: PET-CT scan was positive in 16 patients finding 14 true-positive and 2 false-positive cases (positive pred (mais) ictive value 87.5%). Nine patients had negative PET-CT; two had decrease of TG to undetectable levels. One patient had residual disease detected by post-therapeutic WBS. Six patients had no evidence of tumor during follow-up (mean time 16 months). PET-CT was concordant with CI in 52%, partially concordant in 12% and discordant in 36% (6 false-negatives and 3 false-positive of CI). We observed a tendency of increasing proportion of positive PET-CT with increasing TG. CONCLUSION: PET-CT scan with FDG-18F is useful in the detection of recurrence and/or metastases of DTC with high TG levels but negative WBS. It presents elevated positive predictive value and is superior to CI being more effective as higher the serum TG levels.

Scientific Electronic Library Online (Portuguese)

5

Efeito dose-resposta de uma formulação de dentifrício com concentração reduzida de fluoreto: estudo in vitro/ Dose-response effect of a dentifrice formulation with low fluoride concentration: an in vitro study

Negri, Helena Maria Decico; Cury, Jaime Aparecido
2002-12-01

Resumo em português O desenvolvimento de dentifrício com menor concentração de flúor, visando crianças menores de 6 anos, tem sido sugerido para diminuir o risco de fluorose dental. Para que um dentifrício tenha potencial anticárie é necessário que ele forme no esmalte dental flúor fracamente ligado tipo fluoreto de cálcio (CaF2), o qual é considerado o responsável pelo efeito do flúor tópico. Considerando que a formação de CaF2 é função inversa do pH, foram formulados de (mais) ntifrícios com pH 5,5. Foram preparados dentifrícios com 275, 550 e 1.100 ppm , contendo NaF/sílica, para verificar efeito dose-resposta os quais foram comparados com um placebo e o dentifrício Crest® (controle positivo - padrão). A biodisponibilidade dos dentifrícios, em termos de formação de flúor total (FT), CaF2 e fluorapatita (FA) no esmalte dental humano foi avaliada. Para as dosagens de íon flúor foi utilizado eletrodo específico. Os resultados mostraram que a formulação com 550 ppm de foi mais eficiente que o placebo e aquela com 275 ppm em termos de formação de CaF2 (p 0,05). Uma relação dose-efeito foi observada em termos de CaF2 formado. Os resultados sugerem que a formulação modificada contendo 550 ppm de pode ser considerada equivalente ao dentifrício padrão com 1.100 ppm, a qual seria mais segura em termos de fluorose dental. Resumo em inglês The utilization of dentifrices with low fluorine concentration, for children under 6 years of age, has been suggested to reduce the risks of dental fluorosis. However, in order to have anticariogenic potential, the dentifrice should form loosely-bound fluorine (CaF2) on dental enamel. Considering that the formation of CaF2 is a function inversely related to pH, dentifrices with pH 5.5, with 275, 550 and 1,100 ppm (NaF/silica) we (mais) re developed in order to assess dose-response effects. A comparison between those dentifrices, a placebo product and the Crest toothpaste (positive control - standard) was carried out. Furthermore, the bioavailability of dentifrices, in terms of formation of total fluorine (TF), CaF2, and fluorapatite (FA) on human dental enamel, was evaluated. An ion-specific electrode was utilized for the determination of the dosage of fluorine. The results revealed that the dentifrice with 550 ppm was more effective than both the placebo and the dentifrice with 275 ppm, presenting no difference in relation to the positive control (p > 0.05). A dose-effect correlation was observed as to the CaF2 formed. In conclusion, the modified formulation with 550 ppm can be considered as effective as the standard dentifrice with 1,100 ppm, and its utilization would be safer with regard to dental fluorosis.

Scientific Electronic Library Online (Portuguese)

6

Efeito da substituição por átomos de flúor no equilíbrio conformacional de chalcona/ Effect of fluorine atom substitution on the conformational equilibrium of chalcone

Cesarin-Sobrinho, Dari; Netto-Ferreira, José Carlos; Braz-Filho, Raimundo
2001-10-01

Resumo em inglês Chalcone (1) and its fluorinated derivatives 2-4, as well as their cyclic analogues 5-10, were synthesized through an aldol condensation reaction between the corresponding ketone and aldehyde. These compounds were characterized by IR, EIMS and ¹H and 13C NMR spectral data. Modern NMR techniques allowed us to conclude that the compounds obtained show E configuration. These techniques were also employed to investigate the equilibrium involving the s-cis and s-trans conform (mais) ations of 1-4, with this equilibrium being dependent on the fluorine substitution on both aromatic rings, A or B. IR studies indicated that the yield of the s-cis conformation in the fluorinated derivatives is 57.4±1.4; 88.1±0.4 and 66.4±0.7%, for 2, 3 and 4, respectively, based on previous ¹H NMR calculations for chalcone. Theoretical calculations, using the MMX method, were employed to justify the variation of chemical shifts for the fluorinated derivatives and cyclic analogues. These chemical shifts are consequence of the anisotropic effect showed by the carbonyl group on these compounds.

Scientific Electronic Library Online (Portuguese)