Sample records for evaporative cooling
from WorldWideScience.org

Sample records 1 - 13 shown.



1

Sistemas de resfriamento evaporativo e o desempenho de frangos de corte/ Evaporative cooling systems and the performance of broilers

Sartor, Valmir; Baêta, Fernando da Costa; Luz, Maira Luciana; Orlando, Roberto Carlos
2001-03-01

Resumo em português As condições térmicas no interior de instalações para frangos de corte tem importância vital para o sucesso desta atividade. Desta forma, deve-se buscar o conforto térmico para as aves com o mínimo custo em materiais, equipamentos e energia. Baseado nisto foi desenvolvido um trabalho com o objetivo de avaliar o efeito de três sistemas de resfriamento evaporativo no desempenho de frangos de corte. Para isso, utilizou-se um galpão dividido em quatro partes nas qua (mais) is foram instaladas os tratamentos: ventilador associado a nebulização (VNB), ventilador de alta rotação associado a nebulização (VNA), nebulização (NEB) e nebulização acoplada ao ventilador (NEV). Foi registrado o consumo de ração, o ganho de peso e a mortalidade, obtendo-se assim a conversão alimentar. Os sistemas de resfriamento evaporativo (VNA e VNB) proporcionaram os melhores resultados com os maiores valores de ganho de peso por ave e os menores valores de conversão alimentar e mortalidade. Resultados menos satisfatórios foram observados no NEV, com os menores valores de ganho de peso por ave e maiores valores de conversão alimentar e mortalidade. Resumo em inglês The thermal conditions inside poultry houses are very important for the success of this business. It is however necessary to have an adequate animal thermal confort and a minimum cost of material, equipment and energy. This experiment was carried to verify the effect of evaporative cooling systems on the performance of poultry. The building was divided in four equal sectors. The treatments consisted of ventilator and spraying system (VNB), high rotation ventilator and spr (mais) aying system (VNA), spraying system (NEB), and spraying system connected to the ventilator (NEV). Feed intake, weight gain, mortality of poultry were recorded and the food conversion calculated. It is shown the evaporative cooling systems (VNA e VNB) presented the best results, increasing weight gain with lower values of food conversion and mortalily. The worst results were found for the spraying system connected to the ventilator (NEV).

Scientific Electronic Library Online (Portuguese)

2

Zoneamento do potencial de uso de sistemas de resfriamento evaporativo no sudeste brasileiro/ Mapping of potential use of evaporative cooling systems in Southeastern Brazil

Carvalho, Valcimar F.; Yanagi Junior, Tadayuki; Ferreira, Leandro; Damasceno, Flávio A.; Silva, Mariano P.
2009-06-01

Resumo em português O zoneamento do potencial de uso de sistemas de resfriamento evaporativo (SRE) acoplado a um sistema de ventilação em modo túnel (SVT) foi realizado no presente trabalho, com vistas à criação de frangos de corte na região Sudeste do Brasil. Quatro configurações do sistema foram testadas: a) SVT; b) SVT associado à SRE do tipo material poroso umedecido com 40% de eficiência (SVTPAD40); c) SVT associado à SRE do tipo material poroso umedecido com 70% de eficiên (mais) cia (SVT PAD70) e d) SVT PAD70 associado a sistema de nebulização (SVT PAD70+NEB). O ambiente térmico foi caracterizado por meio do índice de temperatura e umidade, enquanto o desempenho das aves foi determinado pelo consumo de ração diário, ganho de peso diário e conversão alimentar. Dados meteorológicos de 1980 a 2001, disponibilizados pelo Projeto Reanálise-2 do NCEP/NCAR, foram utilizados nesta pesquisa. Verificou-se o efeito benéfico do uso dos SRE, com SVT PAD70+NEB proporcionando as melhores condições de produção, em especial nos meses de setembro e outubro para quase toda a região Sudeste, com destaque para as mesorregiões Norte e Noroeste de Minas Gerais. Resumo em inglês In present research the potential use of evaporative cooling systems (ECS) associated to tunnel ventilation system (TVS) for broiler reared in Southeastern Brazil was studied. Four configuration systems were tested: (a) TVS, (b) TVS associated to a pad cooling system with 40% efficiency (TVSPAD40), (c) TVS associated to a pad cooling system with 70% efficiency (TVSPAD70) and (d) TVSPAD70 associated to a misting system (TVSPAD70+MIST). Thermal environment was characterized (mais) by temperature-humidity index, and the chicken performance was estimated by daily feed intake, daily weight gain and feed conversion. Climatic data from 1980 to 2001, released through Reanalysis-2 Project from NCEP/NCAR were used in this research. The benefitial effect of the use of ECS with TVSPAD70+MIST for providing better production condition was verified, especially during September and October for almost all the southeastern region, mainly in northern and northwestern part of the Minas Gerais State.

Scientific Electronic Library Online (Portuguese)

3

Intermitência do sistema de resfriamento adiabático evaporativo por aspersão em instalação para vacas em lactação/ Sprinkling frequency of adiabatic evaporative cooling system in dairy cow housing

Matarazzo, Soraia V.; Silva, Iran J. O. da; Perissinotto, Mauricio; Fernandes, Dérgio A. de A.
2006-12-01

Resumo em português Teve-se o objetivo de avaliar o período de intermitência de acionamento do sistema de resfriamento adiabático evaporativo (SRAE) por aspersão na linha de alimentação, em instalação do tipo freestall e sua influência no conforto térmico de vacas em lactação. Foram utilizadas 12 vacas multíparas com produção média de 30 kg de leite por dia. Os tratamentos corresponderam às intermitências de 12; 14 e 16 min, e os dados referentes à temperatura do bulbo sec (mais) o (TBS), umidade relativa do ar (UR) e temperatura de globo negro (TGN), no interior da instalação e no ambiente externo, foram mensurados ao longo das 24 h durante todo o período experimental. A freqüência respiratória (FR), temperatura retal (TR) e temperatura do pelame (TP) foram medidas às 13; 14; 15 e 16 h em todos os animais. As variáveis meteorológicas TBS (31,5 ºC), TGN (32,5 ºC) e os índices de conforto térmico ITU (79,0) e ITGU (81,0) foram maiores na intermitência de 12 min quando comparados aos demais tratamentos. A UR mostrou-se mais elevada no tratamento de 14 min (60,3%) em relação à intermitência de 12 min (51,0%). Verificou-se que as vacas em lactação expostas à intermitência de 12 min apresentaram maior valor de TR (39,1 ºC) e FR (76,0 mov min-1) quando comparado aos tratamentos de 14 e 16 min. As intermitências de 14 e 16 min proporcionaram condições ambientais semelhantes e menores valores de TR, FR e TP, mostrando-se eficientes na redução do estresse térmico de vacas em lactação. O intervalo de 16 min empregou menor quantidade de água, podendo ser adotado a fim de evitar desperdícios desnecessários pelo sistema de resfriamento adiabático evaporativo. Resumo em inglês This work aimed to evaluate the effect of sprinkling frequency of adiabatic evaporative cooling system within feed line of a freestall in relation to temperature and humidity index (THI),black globe temperature index (BGHI) and physiological responses in dairy cows. There were used twelve multiparous dairy cows with medium milk production of 30 kg per day. The treatments correspond to sprinkling pulses of 12; 14 and 16 min sprinkler system. Dry bulb temperature (DBT), air (mais) relative humidity (RH) and black globe temperature (BGT), inside and outside of facilities, were measured hourly by a period of 24:00 h. Respiratory frequency (RF), rectal temperature (RT) and skin temperature (ST) were taken at 1:00 p.m., 2:00 p.m, 3:00 p.m. and 4:00 p.m. in all animals submitted to the treatments. The environmental variables, DBT (31.5 ºC) and BGT (32.5 ºC), and thermal comfort indexes, THI (79.0) and BGHI (81.0), were higher with 12 min of sprinkling frequency than the other treatments. The RH was higher with 14 min (60.3%) than with 12 min (51.0%). It was verified that in relation to physiological parameters, dairy cows with 12 min of sprinkling frequency had higher rectal temperature (39.1 ºC) and respiratory frequency (76.0 mov min-1) when compared to the treatments of 14 and 16 min. To avoid unnecessary water waste in the system should be used the interval of 16 min resulting in the smallest water amount used by the sprinkling cooling system.

Scientific Electronic Library Online (Portuguese)

4

Avaliação de materiais alternativos utilizados na confecção de placas porosas para sistemas de resfriamento adiabático evaporativo/ Evaluation of alternative materials used for pad making in the evaporative cooling system

Tinôco, Ilda de F. F.; Figueiredo, José L. A.; Santos, Rodrigo C.; Paulo, Marcos O. de; Vigoderis, Ricardo B.; Pugliesi, Nelson L.
2002-04-01

Resumo em português Objetivou-se, com este trabalho, a comparação entre a eficiência de alguns materiais porosos alternativos encontrados no Brasil: cinasita (argila expandida), serragem, fibra vegetal e carvão, para o Sistema de Resfriamento Adiabático Evaporativo (SRAE). O experimento se deu em condições de verão, em estufas situadas na Universidade Federal de Viçosa, Minas Gerais. O conforto térmico ambiente foi avaliado através do Índice de Temperatura de Globo Negro e Umidad (mais) e (ITGU) e Umidade Relativa do ar (UR), medidos diariamente, a cada duas horas, das 8 às 18 h. Os resultados obtidos foram interpretados através da análise de variância. Com base neste estudo, é possível inferir que a confecção de placas porosas para resfriadores evaporativos, utilizando-se os materiais cinasita e carvão vegetal, indica vantagens sobre os demais materiais estudados (serragem e fibra de madeira). No entanto, como não houve diferença estatística significativa em todos os horários, para os materiais testados e com base nos resultados de umidade relativa do ar e ITGU, sugere-se a condução de novas pesquisas, no sentido de se determinar a espessura correta da placa porosa, tendo em vista a obtenção correta da pressão estática do sistema, sendo este um fator determinante, no que se refere à sua eficiência. Resumo em inglês This study aimed to compare the efficiency of some alternative pad materials found in Brazil, such as the "cinasita" (an expanded clay), the sawdust, the vegetable fiber and coal. The experiment conducted in summer conditions, in greenhouses located in the Federal University of Viçosa, Minas Gerais. The comfort thermal atmosphere was evaluated through the Black Globe Humidity Index (BGHI) and Relative Humidity (RH), measured daily, every two hours, between 8 to 18 h. The (mais) obtained results were interpreted through the variance analysis. On the basis of this study, it is possible to infer that the making of pad for evaporative cooling systems, using the material cinasita and vegetable coal, it indicates advantages compared to other studied materials. However, as there were no significant differences in every schedule, for the tested materials on the basis of results of relative humidity of the air and BGHI. It suggests of new investigations, for the determination of correct thickness of the pad, keeping in view the correct obtaining of the static pressure of the system, as this being a decisive factor, in what refers to its efficiency.

Scientific Electronic Library Online (Portuguese)

5

Avaliação da biomassa foliar de morangueiro hidropônico em diferentes ambientes protegidos/ Leaf biomass evaluation of hydroponic strawberry in greenhouses

Costa, Edilson; Leal, Paulo Ademar Martins
2008-12-01

Resumo em português Realizaram-se experimentos na Faculdade de Engenharia Agrícola na Universidade Estadual de Campinas, utilizando quatro cultivares de morangueiro [Fragaria x ananassa (Weston) Duchesne ex Rozier], quatro sistemas de produção hidropônica (canal de 100mm, canal de 150mm, canal de 150mm, com vaso contendo fibra de coco e tubo vertical contendo casca de arroz carbonizada) e três ambientes protegidos (casa-de-vegetação sem resfriamento evaporativo do ar e sem injeção a (mais) érea de CO2, casa-de-vegetação com injeção aérea de CO2 e sem resfriamento evaporativo do ar e casa-de-vegetação com injeção aérea de CO2 e resfriamento evaporativo do ar). Foram avaliados os parâmetros foliares massa fresca foliar (MFF) e massa seca foliar (MSF) em gramas e área foliar (AF) em mm², correlacionando à biomassa da planta. O melhor sistema foi o de canais de 150mm com vaso contendo fibra de coco. O melhor ambiente foi o de resfriamento evaporativo do ar e injeção aérea de CO2. Resumo em inglês Analyses were made in the experimental field of the Agricultural Engineering College at State University of Campinas (Unicamp). Four varieties of strawberry [Fragaria x ananassa (Weston) Duchesne ex Rozier] were tested in four hydroponics production systems (100mm and 150mm channels and 150mm channel with a vase containing coconut fiber and a vertical pipe containing carbonized rice rusk). Three greenhouses were tested: i) a greenhouse without air evaporative cooling nor (mais) CO2 aerial injection, ii) a greenhouse with CO2 aerial injection and without air evaporative cooling and iii) a greenhouse with CO2 aerial injection and air evaporative cooling. It was analyzed the leaf fresh (MFF) and dry mass in gram (MSF) and the leaf area in mm² (AF). The best hydroponics system was 150mm channel with a vase containing coconut fiber. The best environment condition was the one with air evaporative cooling and aerial injection of CO2.

Scientific Electronic Library Online (Portuguese)

6

Avaliação de variedades de morangueiro em sistemas hidropônicos sob casa de vegetação/ Evaluation of strawberry varieties in hydroponics systems in greenhouses

Costa, Edilson; Leal, Paulo Martins
2008-06-01

Resumo em português Realizaram-se experimentos na Faculdade de Engenharia Agrícola na Universidade Estadual de Campinas, com quatro variedades de morangueiro (Campinas, Seascape, Sweet Charlie e Tudla), em quatro sistemas de produção hidropônica (canal de 100mm, canal de 150mm, canal de 150mm com vaso contendo fibra de coco e tubo vertical contendo casca de arroz carbonizada), em três ambientes protegidos com níveis tecnológicos diferenciados (casa de vegetação sem resfriamento evap (mais) orativo do ar e sem injeção aérea de CO2, casa de vegetação com injeção aérea de CO2 e sem resfriamento evaporativo do ar, e casa de vegetação com injeção aérea de CO2 e resfriamento evaporativo do ar). Foram analisadas as produtividades em gramas por planta (P) e o número de frutos por planta (NF). Destacou-se como melhor variedade a Campinas. O melhor sistema de cultivo foi o de canais de 150mm com vaso contendo fibra de coco. Resumo em inglês Experiments were accomplished in the experimental field of the Faculty of Agricultural Engineering at State University of Campinas (Unicamp). Four varieties of strawberry were tested (Campinas, Seascape, Sweet Charlie and Tudla) in four hydroponics production systems (100mm and 150mm channels and 150mm channel with a vase containing coconut fiber and a vertical pipe containing carbonized rice skin) in three greenhouses with different technical: i) greenhouse without air e (mais) vaporative cooling nor CO2 aerial injection, ii) greenhouse with CO2 aerial injection and without air evaporative cooling and iii) greenhouse with CO2 aerial injection and air evaporative cooling. The productivity in grams per plant (P) and the number of fruits per plant (NF) were analyzed. The variety Campinas was better than the others. The best hydroponics system was the 150mm channel with a vase containing coconut fiber.

Scientific Electronic Library Online (Portuguese)

7

Produção de alface hidropônica em três ambientes de cultivo/ Production of hydroponic lettuce in three environments

Costa, Edílson; Leal, Paulo A. M.
2009-09-01

Resumo em português Propôs-se avaliar a produção hidropônica de alface-crespa, variedade "Vera", em bancadas inclinadas com canais de 100 mm, utilizando a técnica de filme de solução nutritiva, em resposta à aplicação de dióxido de carbono e ao resfriamento evaporativo. Realizaram-se cinco ciclos de cultivo nos períodos de 20-3 a 17-4-2000 (C1); 25-5 a 29-6-2000 (C2); 13-7 a 21-8-2000 (C3); 27-8 a 2-10-2000 (C4) e 12-12-2000 a 10-1-2001 (C5). Avaliaram-se três casas de vegetaç� (mais) �o, sendo casa de vegetação sem sistema de resfriamento evaporativo do ar e sem injeção aérea de CO2 (A1); casa de vegetação com injeção aérea de CO2 e sem sistema de resfriamento evaporativo do ar (A2), e casa de vegetação com injeção aérea de CO2 e com sistema de resfriamento evaporativo do ar do tipo meio poroso-exaustor (A3). Avaliaram-se as massas frescas e secas em gramas, o número de folhas e a área foliar em mm². Utilizou-se do delineamento inteiramente casualizado, em que, no ciclo C1, utilizaram-se 48 repetições por ambiente; para os ciclos C2, C3 e C5, foram 64 repetições, e para o ciclo C4, foram 24 repetições. O ambiente climatizado com incremento de dióxido de carbono promoveu melhor desenvolvimento das plantas, com maior número de folhas comercializáveis. Em ambientes não climatizados, o incremento de CO2 não resultou em aumento de produtividade da alface para a maioria dos ciclos. Em épocas de temperaturas mais elevadas, obtiveram-se plantas maiores, com maior número de folhas. Resumo em inglês It was proposed to evaluate the hydroponic lettuce production, variety "Vera", on inclined benches with channels of 100 mm, and Nutrient Film Technique, as answer to carbon dioxide application and evaporative cooling. There were five cycles of cultivation from March, 20th to April, 17th (C1); from May, 25th to June, 29th (C2); from July, 13th to August, 20th (C3); from August, 27th to October, 10th (C4); from December, 12th to January, 10th (C5). In three greenhouses were (mais) tested the following systems: (A1) without evaporative cooling air CO2 aerial injection, (A2) with CO2 aerial injection and without evaporative cooling and (A3) with CO2 aerial injection and pad-fan evaporative cooling system. The fresh and dry mass of leaves in grams, number of leaves and leaf area in square millimeter were evaluated. The completely randomized statistical analysis was used. The cycle C1 were used 48 replications, for cycles C2, C3 and C5 were used 64 replications and C5 were used 24 replications. The results showed that greenhouse with evaporative cooling system and CO2 allow better development and greater lettuce yield. It was possible to conclude that the aerial injection of CO2, in the absence of evaporative cooling system, did not lead increasing the lettuce productivity to most cycles. Bigger lettuce leaf areas were found in periods with higher temperatures.

Scientific Electronic Library Online (Portuguese)

8

Evaporação em armadilhas atômicas e as temperaturas mais baixas do Universo/ Evaporation on atom traps and the lowest temperatures of the Universe

Iavaronni, A.H.; Henn, E.A.L.; Ramos, E.R.F.; Seman, J.A.; Amthor, T.; Bagnato, V.S.
2007-01-01

Resumo em português Neste trabalho apresentamos um modelo simples de resfriamento evaporativo para átomos ultrafrios aprisionados. Este processo objetiva a diminuição da temperatura da amostra gasosa a partir da retirada dos átomos mais quentes desta e conseqüente retermalização dos remanescentes em uma temperatura mais baixa. O modelo parte da distribuição de Maxwell-Boltzmann de velocidades para a amostra atômica e permite o cálculo da temperatura e número de átomos remanescen (mais) tes nesta após a retirada dos átomos mais quentes e retermalização. A partir dessas expressões simulamos o processo de resfriamento evaporativo realizado usualmente em experimentos, onde são retirados átomos cada vez mais frios após cada retermalização. Resumo em inglês In this work we present a simple model to describe evaporative cooling for ultracold trapped atoms. This process is used to achieve low temperatures of the gaseous sample by removing the hottest atoms and subsequently rethermalizing the remaining atoms at a lower temperature. The model assumes a Maxwell-Boltzmann distribution of velocities in the atomic sample and allows the calculation of the temperature and the number of remaining atoms after the hottest atoms have been (mais) removed and the rethermalization has taken place. Using these expressions we simulate the process of evaporative cooling as it is usually carried out in experiments, where colder atoms are removed after each successive rethermalization.

Scientific Electronic Library Online (Portuguese)

9

Caracterização espacial do ambiente termoacústico e de iluminância em galpão comercial para criação de frangos de corte/ Spatial characterization of thermoacoustic and luminance environment in commercial broiler chicken house

Yanagi Júnior, Tadayuki; Amaral, Adriana G. do; Teixeira, Vitor H; Lima, Renato R. de
2011-02-01

Resumo em português A presente pesquisa teve o objetivo de avaliar e espacializar as variáveis termoacústicas e de iluminância no interior de um galpão comercial, com sistema de ventilação convencional e resfriamento evaporativo, destinado à produção de frangos de corte. Os frangos de corte Hybro foram alojados em um galpão subdividido em três regiões (refugos, fêmeas e machos), sendo criados a uma densidade aproximada de 20 aves m-2. O ambiente produtivo foi avaliado por meio d (mais) o índice de conforto térmico, nível de ruído e de iluminância. Mapas de distribuição espacial destas variáveis foram gerados para o interior do galpão, usando o método da krigagem. Com base nos resultados, pode-se concluir que as aves, de forma geral, estiveram submetidas a condições ambientais inadequados à criação nos horários mais quentes do dia. Porém, verificou-se o potencial de exploração do sistema de resfriamento evaporativo. A espacialização das variáveis relacionadas ao ambiente produtivo proporciona a obtenção de informações mais detalhadas sobre o sistema estudado. Resumo em inglês The goal of this study was to evaluate and map the thermo-acoustic and the luminance variables inside of a commercial broiler chicken house equipped with conventional ventilation and misting system. Hybro breed broiler chickens were lodged in three regions (refuse, female and male), at a density of approximately 20 birds m-2. The productive environment was evaluated by the black-globe humidity index, relative humidity, air velocity, noise level and luminance. Spatial dist (mais) ribution maps of these variables were generated inside the broiler house using the kriging method. Based on the results, it was concluded that, in general, broiler chickens were subjected to inadequate environmental conditions during the hottest period of the day; however, the exploration potential for using evaporative cooling systems was verified. The spatial profile of the variables related to the productive environment provide for the attainment of more detailed information about the studied system.

Scientific Electronic Library Online (Portuguese)

10

Efeito da utilização de sistemas de climatização nos parâmetros fisiológicos do gado leiteiro/ Thermal efficiency of climatization systems in the reduction of thermal stress in free-stall

Perissinitto, Maurício; Moura, Daniella J. de; Matarazzo, Soraia V.; Silva, Iran J. O. da; Lima, Karla A. O. de
2006-12-01

Resumo em português Este trabalho avaliou diferentes sistemas de resfriamento adiabático evaporativo (SRAE) (aspersão e nebulização), conjugados com a ventilação forçada, quanto à eficiência térmica na redução do estresse térmico de bovinos leiteiros. O experimento foi desenvolvido em um rebanho leiteiro comercial localizado em São Pedro - SP, compreendendo 28 dias consecutivos de novembro de 2003, utilizando-se de 10 animais da raça Holandesa em lactação, alojados em sistem (mais) a de "freestall". A umidade relativa do ar, a temperatura ambiente e a temperatura de globo negro foram registradas a cada 15 minutos, durante todo o período. A temperatura retal, a freqüência respiratória e a temperatura dos pelames branco e preto foram medidas nos horários das 9; 11; 13; 15 e 17 h, durante nove dias não-consecutivos. Concluiu-se que os sistemas de resfriamento estudados, comparados entre si, não promoveram diferenças significativas na temperatura retal, na freqüência respiratória e na temperatura média do pelame preto. Já a temperatura média do pelame branco foi significativamente menor no tratamento com aspersão que no tratamento com nebulização, nos horários das 11 e 13 h. O sistema de resfriamento com nebulização promoveu reduções significativas nas temperaturas de bulbo seco, de globo negro e no índice de temperatura de globo e umidade comparado ao sistema de aspersão. Tanto o sistema de aspersão como o sistema de nebulização reduziram, significativamente, a temperatura máxima do abrigo em relação à temperatura do ambiente externo. Resumo em inglês This research evaluated the thermal efficiency of two evaporative cooling systems, sprinkler and misting, associated with forced ventilation, on the dairy cows thermal stress relief. The study was carried out in a commercial dairy cattle farm located in São Pedro city, state of Sao Paulo, Brazil. The duration of the experiment was twenty-eight consecutive days of November 2003, and 10 Holstein cows lodged in a freestall barn were studied. The relative humidity, the dry b (mais) ulb temperature and black globe temperature were registered every 15 minutes, during all experimental period. Among these cows, five were selected for collecting physiological data (respiratory frequency, rectal temperature and temperature in white and black surfaces) at 9:00 a.m., 11:00 a.m., 1:00 p.m., 3:00 p.m. and 5:00 p.m., during nine non-consecutive days. According to the results, it was concluded that both of the cooling systems studied did not cause any significant differences on the rectal temperature, respiratory frequency and temperature in black surface. However, the temperature in white surface was significantly lower in the sprinkling system, at the time of 11 a.m. and 1 p.m. The misting system reduced significantly the wet bulb temperature, black globe temperature and humidity index, when compared to the sprinkling system. Both cooling systems reduced the maximum wet bulb temperature of the barn compared to the external environment.

Scientific Electronic Library Online (Portuguese)

11

Efeitos da climatização do curral de espera na produção de leite de vacas holandesas/ Effects of the climatization of the corral of wait on milk production of holstein cows

Silva, Iran J.O. da; Pandorfi, Héliton; Acararo Jr., Irineu; Piedade, Sônia M.S.; Moura, Daniella Jorge de
2002-09-01

Resumo em português O presente estudo foi conduzido com o objetivo de avaliar os efeitos da climatização de ambientes em condições de pré-ordenha na produção de leite. O experimento foi realizado na fazenda experimental do Instituto de Zootecnia, em Nova Odessa, SP, durante doze dias consecutivos do verão de 1999. Foram analisados os efeitos do sistema de resfriamento evaporativo (SRE), por nebulização, no curral de espera. Utilizaram-se doze animais da raça holandesa, divididos e (mais) m dois grupos de seis animais, onde apenas o segundo grupo foi submetido ao sistema de climatização. Os dados ambientais foram registrados no horário das ordenhas, ou seja, às 7 e 15 h. Para avaliação dos dados ambientais utilizaram-se os índices de conforto térmico: índice de temperatura de globo (WBGT), índice de temperatura e umidade (THI) e índice de carga térmica radiante (CTR). As respostas fisiológicas, como freqüência cardíaca e respiratória, temperatura retal e produção de leite também foram consideradas variáveis de resposta. Conclui-se que o efeito do resfriamento do ambiente é mais significativo no horário da segunda ordenha (15 h), quando comparado ao da primeira (7 h), melhorando as condições de conforto térmico no curral de espera, refletindo em um aumento de 7,28% na produção de leite, além de promover redução na frequência respiratória e cardíaca. Resumo em inglês This work was carried out to evaluate the effect of the climatization of environments in daily pay-milking conditions. The experiment was carried out in the experimental farm of the Institute of Zootecnia, in Nova Odessa, SP, during twelve consecutive days of the summer. The effects of the system of evaporative cooling (SRE), by fogging in the wait corral and milking room were analyzed. Twelve Holstein cows were divided in two groups, where only the second group had passe (mais) d climatization. Data environment were recorded at 7:00 am and 3:00 pm. For evaluation of the ambient data, index of thermal comfort, index of globe temperature (WBGT), temperature humidity index (THI) and index of radiant thermal load (CTR) were used. The physiolological responses as cardiac frequency, respiratory frequency, retal temperature and production had been also considered variable responses. It was concluded that the effect of cooling of the environment is more significant in the schedule of second milking (3:00 pm) when compared to the of the first one (7:00 am), improving the conditions of thermal comfort in the wait corral, contemplating in an increase of 7,28% in the production of milk, besides promoting a reduction in the breathing and heart frequency.

Scientific Electronic Library Online (Portuguese)

12

Investimento em climatização na pré-ordenha de vacas girolando e seus efeitos na produção de leite/ Investment in system in the pre-milking of girolando cows and its effects on milk production

Almeida, Gledson L. P. de; Pandorfi, Héliton; Guiselini, Cristiane; Almeida, Gleidiana A. P. de; Morril, Waldirene B. B.
2010-12-01

Resumo em português Objetivou-se, com este trabalho, avaliar os efeitos da climatização na pré-ordenha sobre o acondicionamento térmico, fisiologia, produção de leite e relação custo/benefício do sistema de resfriamento adiabático evaporativo (SRAE). Utilizaram- -se 16 vacas com produção de 18 kg de leite d-1, adotando-se delineamento em quadrado latino 4 x 4 e comparação entre as médias pelo teste de Tukey (P (mais) animais ao SRAE no curral de espera, 0, 10, 20 e 30 min. A temperatura de bulbo seco (Tbs) e umidade relativa (UR) foram registradas a cada minuto o que permitiu determinar a eficiência do SRAE por meio do índice de temperatura e umidade (ITU) e entalpia (h). A frequência respiratória (FR), temperatura retal (TR) e temperatura de pelame (TP) foram medidas antes e depois da climatização. O tratamento 30 min permitiu manter as variáveis ambientais e os índices de conforto entre os limites recomendados. As variáveis fisiológicas (FR, TR e TP) mostraram valores inferiores no tratamento 30 min, o que refletiu positivamente na produção de leite, com aumento de 4,35%, quando comparado com o tratamento 0 min. O investimento no SRAE promoveu acréscimo na receita mensal, de R$ 1.266,84, com tempo de retorno do capital de 58 dias. Resumo em inglês The objective of this study was to evaluate the effects of cooling of pre-milking cows on production, physiology, thermal conditioning and the cost-benefit of the Adiabatic Evaporative Cooling System (AECS). Sixteen cows were used with an average daily milk production of 18 kg, distributed in 4 x 4 Latin square design. The Tukey test (P(mais) The dry bulb temperature (DBT, ºC) and relative humidity (RH, %) were recorded every minute, which allowed the determination of the efficiency of the AECS through the temperature and humidity Index (THI) and enthalpy (h). The respiratory rate (RR), rectal temperature (RT) and temperature of the coat (TC) were measured before and after cooling. The 30 min. treatment kept the environmental variables and the comfort indexes within recommended limits. The physiological variables (RR, RT and TC) were lower in the 30 min treatment and reflected positively on milk production, which increased 4.35% compared to the control treatment (0 min). The investment was profitable having a 58 day return on investment and a monthly revenue increase of R$ 1,266.84.

Scientific Electronic Library Online (Portuguese)

13

Avaliação da produção de leite em bovinos utilizando diferentes sistemas de climatização/ Evaluation of the production in dairy cattle in different climatization systems

Perissinotto, M.; Moura, D. J. de; Cruz, V. F. da
2007-01-01

Resumo em português O presente estudo avaliou a eficiência térmica de diferentes sistemas de arrefecimento evaporativo; aspersão (TA) e nebulização (TN), conjugados com a ventilação forçada, quanto à melhoria do microclima interior das instalações e na resposta produtiva dos animais. O estudo foi realizado numa vacaria em sistema de estabulação livre localizada no interior de São Paulo/Brasil, tendo sido utilizado 10 animais da raça Holstein Freisian por tratamento. A recolha (mais) de dados efectuou-se, durante 21 dias consecutivos. No interior da vacaria recolheram-se os dados climáticos, em cada tratamento, e calculou-se o Índice de Temperatura e Humidade (THI). Os sistemas de arrefecimento avaliados não diferiram estatisticamente ao longo do período de estudo. Os sistemas só foram accionados quando a temperatura ambiente ultrapassou os 24 ºC. Ambos os tratamentos (TA e TN) mantiveram um ambiente com condições temohigrométricas acima das recomendadas pela literatura. O consumo alimentar foi semelhante em ambos tratamentos, porém, o sistema de arrefecimento por aspersão (TA) promoveu um aumento na produção de leite de 8%, relativamente ao sistema por nebulização (TN). Resumo em inglês This study evaluated the thermal efficiency of different systems of evaporative cooling; sprinkling (TA) and fogging (TN), conjugated with the forced ventilation, in the improvement of the internal microclimate of the installations and in the productivity of dairy cattle. The study it was carried through a cow house provided with free-stall system in the interior of Sao Paulo/Brasil.Ten animals of Holstein Frisian breed per treatment were used. Collection of data occurred (mais) in November of 2003 during 21 consecutive days. Outside and inside climatic data in each treatment were recorded and the Index of Temperature and Humidity (THI) was calculated. The system of evaporative cooling evaluate had not differed with relation to the climatic variables. Both systems (TA and TN) had kept an environment with thermohygrometric conditions inside that recommended in the literature. The feed intake was similar with both cooling systems, however, the system of cooling by sprinkling (TA) leads to an increase of 8% in the milk production, compared with the fogging system (TN).

Scientific Electronic Library Online (Portuguese)