Sample records for electrical resistivity
from WorldWideScience.org

Sample records 1 - 20 shown. Select sample records:



1

Medidas de resistividade elétrica DC em sólidos: como efetuálas corretamente/ DC electrical resistivity measurements in solids: how to proceed correctly

Girotto, Emerson M.; Santos, Ivair A.
2002-07-01

Resumo em inglês This paper deals with the most common methods for determining the dc electrical resistivity in solid materials. A brief overview of the fundamental concepts related to the electrical resistivity on materials is introduced. Undoubtedly, the most common and useful procedure to determine the electrical resistivity (rho) is the fourpoint probe method. Some crucial mistakes regarding the experimental procedure and the appropriated correction factors are found in the literature (mais) . Thus, the correction factor for the most common sample geometries were gathered and revised in order to provide an easy way to use and apply them.

Scientific Electronic Library Online (Portuguese)

2

Gamaespectrometria, resistividade elétrica e susceptibilidade magnética de solos agrícolas no noroeste do estado do Paraná

Becegato, Valter Antonio; Ferreira, Francisco José Fonseca
2005-12-01

Resumo em português Medições gamaespectrométricas, de resistividade elétrica e de susceptibilidade magnética foram tomadas em solos agrícolas situados próximos a cidade de Maringá, noroeste do estado do Paraná, sul do Brasil, objetivando caracterizar a distribuição espacial das concentrações de radionuclídeos (K, eU e eTh), da resistividade aparente e da susceptibilidade magnética. Na área agrícola ocorrem três tipos de solos: Nitossolo Vermelho Eutrófico, Latossolo Vermel (mais) ho Eutroférrico textura argilosa, ambos derivados da Formação Serra Geral (basaltos do Cretáceo Inferior) e Latossolo Vermelho Distrófico textura média, oriundo do retrabalhamento das formações Serra Geral e Goio-Erê, esta última composta por arenitos do Grupo Caiuá (Cretáceo Superior). Constatou-se que as concentrações de radionuclídeos e os valores de susceptibilidade magnética nos solos mais argilosos foram maiores do que nos solos mais arenosos, em função, principalmente, da maior adsorção dos primeiros e da maior disponibilidade de minerais magnéticos. Os teores médios em ppm e Bq Kg-1 de K, eU e eTh na área com atividade antrópica foram respectivamente de 1766-54,75; 0,83-10,22 e 1,78-7,27, significativamente maiores do que em áreas virgens sem aplicação de fertilizantes (1101-34,15 de K; 0,14-1,69 de eU e 1,31-5,36 de eTh, respectivamente em ppm e Bq Kg-1). Houve correlações entre os teores de urânio e argila, urânio e susceptibilidade magnética, urânio e matéria orgânica e entre resistividade elétrica e argila. Foram também observadas variações nas concentrações de radionuclídeos em diferentes formulações de adubos utilizados nas culturas de soja e trigo. A resistividade elétrica aparente, cuja magnitude variou de 25 a 647 Ohm.m, e a susceptibilidade magnética, com oscilações entre 0,28 e 1,10 × 10-3 SI, decorrentes dos teores de argila e de minerais magnéticos, respectivamente, se mostraram importantes na discriminação dos solos na área de estudo, podendo ser incorporadas como ferramentas rápidas e de baixos custos no mapeamento sistemático de solos. Resumo em inglês Gamma-ray spectrometry, electrical resistivity, and magnetic susceptibility measurements were taken from agricultural areas near the City of Maringá, in the Northwest region of the Paraná state, south Brazil, in order to characterize the spatial distribution of radionuclides (K, eU, and eTh), the apparent resistivity, and the magnetic susceptibility determined for soils. Three different types of soils are present in this agricultural area: Alfisoil, clayey texture Oxiso (mais) il, both deriving from Lower Cretaceous basalts of the Serra Geral Formation; and medium texture Oxisoil from reworked Serra Geral and Goio-Erê formations, the latter deriving from sandstones of the Upper Cretaceous Caiuá Group. It could be observed that in more clayey soils both concentration of radionuclides and susceptibility values are higher than in more sandy soils, especially due to the higher adsorption in the former and to the higher availability of magnetic minerals in the latter. The average ppm and Bq Kg-1 grades for K, eU, and eTh in the areas under anthropic activity are of 1766-54.75, 0.83-10.22, and 1.78-7.27, respectively. These grades are significantly higher than those of non-occupied or non-fertilized areas (1101-34.15 K, 0.14-1.69 eU, and 1.31-5.36 eTh in ppm and Bq Kg-1, respectively.) Correlations were observed between uranium and clay, uranium and magnetic susceptibility, uranium and organic matter, and between electric resistivity and clay grades. Varied concentrations of radionuclides were also observed in different fertilizer formulations applied to soy and wheat cultures. Apparent electric resistivity values between 25 and 647 Ohm.m and magnectic susceptibility values between 0.28 e 1.10 × 10-3 SI due to clay and magnetic minerals represented important soil discrimination factors in the study area that can be incorporated as easy, low-cost soil mapping tools.

Scientific Electronic Library Online (Portuguese)

3

Radiação gama e resistividade elétrica em solo com aplicação de carbonatito e fertilizantes agrícolas no Distrito Federal

Nascimento, Carlos Tadeu Carvalho do; Ferreira, Francisco José Fonseca; Andrade, Leide Rovênia Miranda de; Gaspar, José Carlos; Pires, Augusto Cesar Bittencourt
2008-03-01

Resumo em português A Embrapa Cerrados e a Universidade de Brasília desenvolveram um projeto que estudou a viabilidade da aplicação de carbonatito como fertilizante agrícola. Como experimento piloto, utilizaram-se diferentes misturas de carbonatito, calcário, superfosfato triplo (SFT) e cloreto de potássio (KCl) como fertilizantes em uma área de latossolo vermelho, na região central do Distrito Federal. Esta área foi dividida em 56 parcelas medindo 4 × 7m nas quais foram adicionada (mais) s as misturas de fertilizantes. Este trabalho teve por objetivo verificar se a adição das misturas ao solo modificou suas características radiométricas e de resistividade e se é possível identificar esta mudança. Realizaram-se medições da radiação gama e de resistividade elétrica na área do experimento e em uma área de cerrado nativo. Os resultados mostraram que a adição dos fertilizantes ao solo causou uma pequena elevação dos teores de K, U e Th e diminuiu cerca de dez vezes os valores de resistividade elétrica. Observou-se um baixo contraste radiométrico entre as parcelas que compõem o experimento, de modo que não foi possível diferenciar os vários tratamentos com base nas medidas gamaespectrométricas. A resistividade elétrica mostrou-se capaz de individualizar três grupos de parcelas em relação às características das misturas adicionadas, respectivamente com predomínio de SFT, de KCl e da mistura exclusiva de calcário e carbonatito. Resumo em inglês EMBRAPA (Empresa Brasileira de Pesquisa Agropecuária) and Brasília University developed a research project about the viability of carbonatite rock as agricultural fertilizer. As an initial experiment, several mixtures of carbonatite, limestone, phosphorous and potassium compounds were added as fertilizers in an oxisol area (red-latosol, according with Brazilian System of Soil Classification), in Distrito Federal, central Brazil. The experiment area was divided in 56 plo (mais) ts (4 × 7m) and each plot received a fertilizer mixture. The purpose of this work was to verify if the addition of fertilizer mixture to the soil modified its radiometric and resistivity properties and if it is possible to identify this change. Gamma-ray and electrical resistivity measurements were obtained in an experimental area and in a natural savannah type vegetation area. The results showed that the fertilizer addition modified soil natural properties causing a small increase in K, U, Th levels and decreasing ten times electrical resistivity. A low contrast of radiation was observed between plots, and then it was not possible to differentiate the several treatments in base of gamma-ray measurements. Electrical resistivity was efficient to identify three groups of plots related to mixtures characteristics, respectively with phosphorous, potassium and limestone / carbonatite predominance.

Scientific Electronic Library Online (Portuguese)

4

Estudo da influência de adições de prata na resistividade elétrica da liga Cu-5%Al/ Influence of silver additions on the electrical resistivity of the Cu-5%Al alloy

ADORNO, Antono Tallarico; SAGGIN, Neivaldo Strutzel; FUGIVARA, Cecílio Sadao; CILENSE, Mário; BEATRICE, Carlos Sobreira
1999-01-01

Resumo em português Estudou-se a influência de adições de 2, 6 e 8% Ag, em peso, na resistividade elétrica da liga Cu-5%Al, utilizando-se o método dos quatro pontos e um sistema de registro contínuo de variação da resistividade elétrica com a temperatura. Os resultados obtidos indicaram que a resistividade elétrica da liga aumenta com o aumento da concentração de prata e que as inflexões observadas nas curvas de variação da resistividade com a temperatura de aquecimento podem (mais) ser atribuídas à solubilização da prata na matriz de Cu-Al. Observou-se também que a velocidade de aquecimento da amostra é um fator importante na intensidade e forma dos eventos observados. Resumo em inglês The influence of additions fo 2, 6, and 8 wt. % Ag on the electrical resistivity of the Cu-5 wt. %Al alloy was studied by the four-probe d.c. method and an automated recorder system. The results indicated that the electrical resistivity of the alloy increases with silver concentration and that the inflexions on the curves of electrical resistivity changes with temperature may be ascribed to silver solubilization on the Cu-Al matrix. It was also observed that the sample heating rate may change the shape of the curve recorded.

Scientific Electronic Library Online (Portuguese)

5

Zircônia tetragonal policristalina. Parte II: Microestrutura e resistividade elétrica/ Tetragonal zirconia polycrystals. Part II: Microstructure and electrical resistivity

Tadokoro, S. K.; Muccillo, E. N. S.
2001-06-01

Resumo em português Nesta segunda parte são mostrados os resultados obtidos em cerâmicas densas de ZrO2: 3% mol Y2O3 (Y-TZP) e 12% mol CeO2 (Ce-TZP), analisadas por espectroscopia Raman, microscopia eletrônica de varredura, e por espectroscopia de impedância. Os resultados mostram que, para ambos tipos de amostras, é possível obter cerâmicas densas (> 95% da densidade teórica) para temperaturas de sinterização inferiores a 0,45 T F (T F = temperatura de fusão). A taxa de crescimen (mais) to de grãos é dependente do cátion estabilizante, sendo maior para a Ce-TZP do que para a Y-TZP. Os espectros Raman de cerâmicas sinterizadas mostram as bandas típicas associadas aos modos ativos da fase cristalográfica tetragonal. Os resultados de espectroscopia de impedância são similares aos obtidos por outros pesquisadores tanto para cerâmicas convencionais quanto nanofásicas no caso da Y-TZP. Para a Ce-TZP foi observada uma redução na condutividade extrínseca em conseqüência da maior pureza do precursor cristalizado. Resumo em inglês Results on dense ZrO2: 3 mol% Y2O3 (Y-TZP) and 12 mol% CeO2 (Ce-TZP) ceramics are shown in this second part. Sintered specimens were analyzed by Raman spectroscopy, scanning electron microscopy and impedance spectroscopy. The main results show that both types of solid solutions may attain a high densification (> 95% of the theoretical density) for sintering temperatures lower than 0.45 T F (T F = melting temperature). The rate of grain growth is governed by the stabilizin (mais) g cation and is faster for Ce-TZP than for Y-TZP. Raman spectra exhibit the six characteristic bands of the tetragonal phase for both specimens. Impedance spectroscopy results for Y-TZP do not differ from those obtained for nanophase ceramics. A reduction in the extrinsic conductivity due to the high purity of the crystallized precursor was observed for Ce-TZP specimens.

Scientific Electronic Library Online (Portuguese)

6

Avaliação hidrogeológica do aqüífero Urucuia na bacia do rio das Fêmeas - BA usando resistividade e polarização elétrica induzida

Amorim Junior, Vicente; Lima, Olivar A.L. de
2007-06-01

Resumo em português Usando sondagens de IP-resistividade pudemos definir a geometria estrutural e a variabilidade litológica do aqüífero Urucuia na bacia do rio das Fêmeas, Bahia. Um total de 80 SEV's Schlumberger foi executado dentro desta bacia hidrológica, medindo-se simultaneamente a resistividade elétrica e a cargabilidade no domínio do tempo, até um espaçamento máximo entre eletrodos de corrente AB/2 de 1000 m. Após inversão quantitativa das sondagens foram construídos map (mais) as de contorno da profundidade do substrato do aqüífero, da profundidade da superfície freática, da resistividade média do aqüífero (ro), e da polarizabilidade da parte superior do aqüífero (mS). O aqüífero consiste de corpos empilhados de arenitos que formam camadas de diferentes resistividades, as quais recobrem um substrato regional argiloso muito mais condutor. Os valores elevados de mS, sugerem que o aqüífero é composto litologicamente de arenitos argilosos saturados com água subterrânea doce. A espessura do reservatório aumenta de leste para oeste, variando de aproximadamente 100 m no centro do município de São Desidério a mais de 450 m na borda da Serra Geral. O fluxo geral da água subterrânea é de oeste para leste, a não ser numa pequena parcela próximo à borda da serra onde ele é invertido e origina um divisor de água subterrânea dentro da bacia hidrológica. A inversão conjunta dos dados de IP e de resistividade foi útil para reduzir ambigüidades geoelétricas e definir melhor a profundidade do nível estático da água subterrânea. Os resultados obtidos são de grande valia para um planejamento sustentável de exploração de água na região, que pode estar sendo super-explorada por um uso agrícola extensivo e acelerado. Resumo em inglês Using IP-resistivity soundings it is possible to define the structural geometry and the lithological variability within the Urucuia aquifer in the Rio das Fêmeas basin, Bahia. A total of 80 Schlumberger VES, measuring simultaneously the electrical resistivity and the time domain chargeability, were performed within this hydrological basin to a maximum current electrode spacing (AB/2) of 1000 m. Contour maps of the depth to the aquifer substratum, the depth to the phreati (mais) c surface, the mean aquifer resistivity (rho), and the upper aquifer polarization (mS) were constructed after the quantitative inversion of the soundings. The aquifer consists of stacked sandstone bodies forming layers of different resistivity overlaying a much more conductive regional shaly substratum. High values of rho and mS, for the aquifer model suggest it is dominantly composed of shaly sandstones but saturated with very fresh groundwater. The reservoir thickness increases from east to west, ranging from about 100 m in the middle of São Desidério County to more than 450 m at the edge of the Serra Geral scarps. The general groundwater flow is from west to east, except in a small portion near the scarps were it is reversed forming a groundwater divide inside this hydrological basin. The jointly inversion of the IP and resistivity data was useful to reduce geoelectrical ambiguities and to better define the water table depths. The achieved results are of great value for planning a sustainable water exploration program for the region, which is being stressed by an accelerated agricultural development.

Scientific Electronic Library Online (Portuguese)

7

Aplicação da resistividade e cargabilidade em estudos de contaminação de sedimentos por derivados de hidrocarbonetos

Braga, Antonio Celso de Oliveira; Cardinali, Maíra Tozzi
2005-06-01

Resumo em português Esse trabalho descreve os resultados obtidos com os métodos da eletrorresistividade e polarização induzida, usando as técnicas de campo da sondagem elétrica vertical (arranjo Schlumberger) e caminhamento elétrico (arranjos dipolo-dipolo e gradiente). Os estudos foram efetuados em modelos reduzidos, em tanques contendo sedimentos areno-argilosos e arenosos da Formação Rio Claro, contaminados por derivados de hidrocarbonetos (gasolina). Os ensaios demonstraram que a (mais) resistividade dos sedimentos aumentou significativamente, imediatamente após a contaminação, enquanto que a cargabilidade diminuiu sensivelmente. As contaminações foram monitoradas durante dez meses, sendo observado que após seis meses, a resistividade dos materiais superficiais tornou-se menor, em relação às leituras sem contaminação, enquanto que as cargabilidades mantiveram-se baixas. Os dados obtidos foram interpretados qualitativamente e quantitativamente (1-D e 2-D). Resumo em inglês This paper describes the results obtained with DC resistivity and time domain induced polarization (IP) electrical methods, through the vertical electrical sounding (Schlumberger array) and profiling (dipole-dipole and gradient arrays) techniques. This study was conducted in reduced models, with in tanks containing clay-sand layer and sand layer sediments of the Rio Claro Formation, contaminated with gasoline. Our results demonstrated that the resistivity of the sediments (mais) increased significantly, immediately after the contamination, but their chargeability decreased sensibly. The contaminated soils were monitored for ten months, being observed that after six months, the resistivity of the superficial materials became lower, in relation to the readings without contamination, while the chargeability stayed drops. The obtained data were interpreted in a qualitative and quantitative by using 1-D and 2-D models.

Scientific Electronic Library Online (Portuguese)

8

Análise térmica e caracterização elétrica de materiais cerâmicos com comportamento termistor à base de óxidos de manganês, de níquel e de cobalto/ Thermal analysis and electrical characterization of ceramic thermistors based on manganese, nickel and cobalt oxides

Ferreira Jr., J. M.; Cordeiro, O. C.; França, Y. V.; Muccillo, E. N. S.; Matos, J. R.; Muccillo, R.
2007-12-01

Resumo em português Materiais cerâmicos à base de óxidos de manganês, de níquel e de cobalto foram preparados por meio de mistura de óxidos seguida de homogeneização e sinterização a 1250 ºC. Os compostos foram caracterizados por meio das técnicas de difração de raios X e microscopia eletrônica de varredura. Análise termogravimétrica foi feita sob atmosferas oxidante e redutora. O comportamento termistor foi estudado por meio de medidas de resistividade elétrica pela técni (mais) ca dc de duas pontas de prova entre temperatura ambiente e 220 °C. Os principais resultados mostram a preparação de termistores em ampla faixa de resposta elétrica por meio da variação da composição relativa dos óxidos de manganês, de níquel e de cobalto. Resumo em inglês Ceramic thermistors based on manganese, nickel and cobalt oxides were prepared by mixing these oxides followed by pressing and sintering at 1250 °C. The oxides were characterized by X-ray diffraction and scanning electron microscopy. The thermistor behavior was studied by two-probe dc electrical resistivity measurements in the room temperature-220 °C range. The main results show the possibility of preparing thermistors in a wide range of electrical response by suitable choice of the relative concentrations of the precursor oxides.

Scientific Electronic Library Online (Portuguese)

9

Contaminação por chorume e sua detecção por resistividade

Gallas, José Domingos Faraco; Taioli, Fabio; Silva, Sandra Márcia Cesário Pereira da; Coelho, Osmar Gustavo Wöhl; Paim, Paulo Sérgio Gomes
2005-03-01

Resumo em português Ensaios geofísicos de eletrorresistividade foram efetuados junto ao aterro sanitário do Município de Londrina, permitindo a detecção e mapeamento da pluma de contaminação pelo chorume. A área de estudo situa-se na Bacia do Paraná, a qual está localmente representada pelas rochas basálticas da Formação Serra Geral. Estabeleceu-se uma correlação entre os valores mais baixos de resistividade e as possíveis contaminações, uma vez que a condução elétrica, (mais) em condições naturais, ocorre principalmente através de íons, que são abundantes no chorume. O fluxo da contaminação principal apresenta uma direção geral SE. Uma descoberta inesperada deste trabalho foi a identificação de outra direção do fluxo da pluma de contaminação para SW, a qual flui através de fraturas horizontais ou superfícies de alteração em contatos dos derrames basálticos. Resumo em inglês Resistivity geophysical techniques were applied closed to the Londrina's county sanitary landfill, allowing the detection and mapping of leachate contamination plume. The study area lies on the Paraná Basin which is locally represented by basaltic rocks of the Serra Geral Formation. A correlation between lower resistivity values and the supposed leachate contaminations was stablished, once the electrical conduction, under natural conditions, occurs mainly in an ionic way (mais) , which are normally presented in the leachate. The main contamination flows in a general SE direction. An unexpected finding of this work was the detection of another flux direction of contamination plume to SW, which flows trough horizontal fractures or alteration surfaces of basaltic contacts.

Scientific Electronic Library Online (Portuguese)

10

Investigações geofísicas na borda da bacia sedimentar de São Paulo

Borges, Welitom Rodrigues; Porsani, Jorge Luís
2002-12-01

Resumo em português Este artigo mostra resultados parciais de investigações geofísicas realizadas na borda da Bacia Sedimentar de São Paulo, dentro do campus da Universidade de São Paulo. O principal objetivo desta pesquisa é a caracterização dos sedimentos e do topo das rochas do embasamento da bacia, utilizando os métodos GPR-Ground Penetrating Radar e Resistividade Elétrica. Os perfis geofísicos foram realizados ao longo de uma mesma linha, visando comparar os resultados com as (mais) duas metodologias. Um perfil de 216m foi adquirido com as antenas de 50 MHz e um perfil de resistividade com dipólos de 20m. Além disso, duas Sondagens Elétricas Verticais - SEV's foram feitas sobre a mesma linha. A análise do perfil GPR permitiu identificar o limite entre a base do solo e uma camada de areia. Os resultados estão de acordo com as informações de poços. O perfil elétrico identificou uma zona anômala de condutividade entre 80 e 110 m, relacionada provavelmente com uma zona de cizalhamento. Resumo em inglês This paper shows partial results of geophysical investigations carried out in the border of São Paulo Sedimentary Basin, within the São Paulo University campus. The main objective of this research is characterizing the sediments and the top of basement rocks using the GPR - Ground Penetrating Radar and Resistivity Methods. The geophysical profiles were carried out along the same line in order to compare results obtained from these methodologies. One GPR profile (216m) w (mais) as acquired employing 50MHz antennas and one resistivity profile with dipole length of 20m. Besides two verticals electrical soundings (VES) measurements were done on the same line. The analysis of GPR profile permitted to identify the bottom boundary the soil and one coarse sand layer. The result was supported by borehole information. The electrical profile identified one conductivity anomaly zone between 80 and 110m, related probably with a shear zone.

Scientific Electronic Library Online (Portuguese)

11

Preparação, sinterização e espectroscopia de impedância da zircônia parcialmente estabilizada com cálcia/ Synthesis, sintering and impedance spectroscopy of calcia-partially stabilized zirconia

Muccillo, E. N. S.; Buissa Neto, R. C.; Tadokoro, S. K.; Muccillo, R.
2006-09-01

Resumo em português Cerâmicas de zircônia parcialmente estabilizada com cálcia foram preparadas com pós nanométricos obtidos pela técnica da co-precipitação. A sinterização dos compactos foi feita a 1500 ºC com tempos de patamar de 3 min e 2 h para o estudo do efeito produzido por diferentes fases na resistividade elétrica da cerâmica sinterizada. O estudo da decomposição térmica do gel mostrou que a formação do óxido ocorre a temperaturas relativamente baixas. A área de (mais) superfície específica é elevada quando comparada com valores dos materiais comerciais. A densificação de compactos preparados com pós nanométricos inicia a temperaturas inferiores a 1000 ºC, mas a cinética de sinterização é dependente da fase formada durante o aquecimento. Os compactos sinterizados apresentam fases distintas dependendo do tempo de sinterização à mesma temperatura. A contribuição relativa das fases formadas na zircônia parcialmente estabilizada para a resistividade elétrica das cerâmicas sinterizados pode ser diferenciada por meio de medidas de espectroscopia de impedância. Resumo em inglês CaO-partially stabilized ZrO2 ceramics were prepared from nanosized powders synthesized by the coprecipitation technique. In order to study the effect of different crystallographic phases on the electrical resistivity, powder compacts were sintered at 1500 ºC for soaking times of 2 h and 3 min. The thermal decomposition of the precursor gel occurs at low temperatures giving rise to a high specific surface area powder material. The densification of powder compacts starts (mais) at temperatures lower than 1000 ºC, although the sintering kinetics depends on the crystallographic phase formed during heating of the compact. The phase assemblage of sintered compacts depends on the soaking time. Impedance spectroscopy measurements allowed for identification of the relative contribution of different phases to the total electrical resistivity of calcia-partially stabilized zirconia ceramics.

Scientific Electronic Library Online (Portuguese)

12

Geofísica elétrica na caracterização da hidrologia subterrânea na região do Aterro Metropolitano Centro, Salvador, Bahia/ Electrical geophysics in the subsurface hydrology characterization around the Salvador's sanitary landfill area, State of Bahia

Cavalcanti, Susana S.; Sato, Hédison K.; Lima, Olivar A. L.
2001-08-01

Resumo em português Dados de sondagens elétricas verticais de resistividade, de polarização induzida (PI), e medidas superficiais de potencial espontâneo (PE), permitiram avaliar as condições hidrológicas subterrâneas na região do novo aterro sanitário de Salvador, Bahia, antes de sua efetiva utilização. A inversão conjunta dos dados de PI-resistividade permitiu diferenciar zonas de maior argilosidade nos arenitos da Formação Barreiras. Permitiu também mapear a topografia do (mais) substrato aqüífero, a conformação do nível do lençol freático e os padrões gerais da circulação subterrânea de água nessa formação. Os dados de PE, obtidos em torno das duas primeiras células já construídas para disposição do lixo, confirmam a orientação geral do fluxo hídrico e definem as principais áreas de recarga e descarga no entorno das células. O quadro hidrológico-petrofísico resultante constitui um referencial útil para checar eventuais danos ambientais futuros relacionados à disposição de lixo urbano na área. Resumo em inglês Resistivity and induced polarization (IP) vertical electrical sounding data, and superficial self-potential (SP) survey, allow to evaluate the underground hydrological conditions around the new Salvador's sanitary landfill. The inversion of the combined IP-resistivity data allows to differentiate zones of large shaliness within the sandstones of Barreiras Formation. They also allow to map the aquifer substratum topography and the water table configuration, as well as to i (mais) nfer the general pattern of the underground natural flow of water. The SP data, acquired around the first two cells already constructed for waste disposal confirm the general underground flow and identified areas of recharge and discharge around the cells. The resulting hydrological-petrophysical picture may be a useful reference frame to check eventual environmental impacts in the future, caused by the waste disposal in the area.

Scientific Electronic Library Online (Portuguese)

13

Investigação dos principais processos de corrosão em estações de energia elétrica do Estado do RS/ Investigation of the main corrosion processes on electrical energy stations of the state of Rio Grande do Sul - Brasil

Rieder, E.S.; Brusamarello, V.; Bianchi, A.L; Balbinot, A.
2009-01-01

Resumo em português Este estudo investigou os principais agentes de corrosão em quatro subestações de energia elétrica do estado do Rio Grande do Sul, três no litoral e uma em Porto Alegre. O objetivo foi determinar as taxas de corrosão de vários materiais metálicos expostos aos agentes agressivos existentes no ambiente das subestações. Foram desenvolvidos experimentos de perda de massa dos materiais expostos em tempo real nas subestações, monitoramento de potencial do solo, dete (mais) rminação da composição química e resistividade do solo, e análise micrográfica e química dos materiais após exposição no sítio de trabalho. Os ensaios de perda de massa foram realizados seguindo as normas ISO (International Organization of Standardization) 8407, 8565 e 9223 a 9227. A resistividade do solo foi determinada pelo método Wenner e as micrografias e constituição química dos produtos de corrosão por microscopia eletrônica de varredura e espectroscopia de energia dispersiva, respectivamente. Resultados mostraram significativa alteração nas massas do aço e do cobre, principalmente nas subestações litorâneas. Embora os agentes corrosivos existam no solo, as altas taxas de corrosão no litoral estão fortemente associadas à maresia. Já para o zinco e o aço galvanizado, a corrosão foi mais expressiva em Porto Alegre, região urbana sem presença de maresia. Os solos de todas as subestações estudadas apresentaram alta resistividade, o que implica em baixa agressividade destes aos materiais metálicos. Com estas conclusões, fica evidente que os procedimentos e precauções em relação à corrosão dos componentes metálicos das subestações expostas a condições extremas de agressividade, como em presença de íons cloreto e particulados sólidos, não podem ser os mesmos que os adotados para os ambientes livres destes componentes. Resumo em inglês This study investigated the main corrosion agents in four electric energy station in the state of Rio Grande do Sul, three on the coast and one in Porto Alegre (capital of Rio Grande do Sul). The objective was to determine the corrosion rates of various metallic materials exposed to the aggressive agents present in the stations atmosphere. Loss mass experiments of the materials exposed in real time in the electric stations, soil potential monitoring, soil resistivity meas (mais) urement, soil chemical analysis, and micrographic and chemical analysis of the materials after exposure in the study sites were performed. The loss mass experiments were performed using the International Organization of Standardization, ISO, 8407, 8565 e 9223 a 9227. The soil resistivity was determined using the Wenner method and the micrographs and chemical analysis of the corrosion products were obtained using scanning electron microscopy and energy dispersive spectroscopy, respectively. Results showed significant change in the mass of steel and cooper, mainly in the stations located on the coast. Although the corrosive agents are present in the soil, the high corrosion rates on the coast were strongly associated with the marine atmosphere. All station soils presented high resistivity, which implies low aggressiveness to metallic materials. With these conclusions, it is evident that the procedures and precautions related to corrosion of the metallic components exposed to conditions of extreme aggressiveness, such as those in the presence of chloride ions and solid particulates, cannot be the same as the ones used for the atmospheres free of these components.

Scientific Electronic Library Online (Portuguese)

14

Efeito da temperatura de calcinação e do teor de dopante nas propriedades físicas da céria-gadolínia preparada pela complexação de cátions com ácido cítrico/ Effect of the calcination temperature and dopant content on the physical properties of ceria-gadolinia prepared by the cation complexation technique

Rocha, R. A.; Muccillo, E. N. S.
2001-12-01

Resumo em português Soluções sólidas de céria-gadolínia foram preparadas pela técnica de complexação de cátions utilizando o ácido cítrico como agente complexante. Os principais objetivos foram avaliar as condições ideais de calcinação para a obtenção de pós nanométricos com elevada sinterabilidade, e verificar o efeito do teor de dopante na densificação e na resistividade elétrica de cerâmicas sinterizadas. Os principais resultados mostram que soluções sólidas cont (mais) endo partículas 99% para sinterização a 1500 ºC. Resumo em inglês Ceria-gadolinia solid solutions were prepared by the cation complexation technique using citric acid as complexant agent. The purposes of this work were to evaluate de calcining profile of the precursor resin in order to obtain nanosized powders with high sinterability; and to verify the effects of dopant content on densification and electrical resistivity of sintered specimens. The main results show that powders with less than 10 nm crystallite size may be obtained at re (mais) latively low temperatures. Gadolinium oxide enhances the densification of pressed specimens reaching a relative density > 99% for the Ce0.8Gd0.2O1.9 composition sintered at 1500 ºC for 3 h.

Scientific Electronic Library Online (Portuguese)

15

Desenvolvimento do pigmento condutor SnO2 -Sb2O3 e sua aplicação em vidrados semicondutores/ Development of a SnO2 -Sb2O3 conductor pigment and its applications in semiconductor glazes

Aguiar, R.; Paskocimas, C. A.; Leite, E. R.; Longo, E.; Maurício, M. R. D.
2004-06-01

Resumo em português Esmaltes semicondutores são utilizados no recobrimento de isoladores elétricos para evitar descargas superficiais nos isoladores, associadas a grandes diferenças de potencial, proporcionando uma melhora no desempenho sob poluição ambiental. Como os vidrados utilizados nas indústrias cerâmicas são isolantes, uma maneira de torná-los semicondutores é adicionando óxidos condutores. Misturou-se ao esmalte porcentagens variadas do pigmento condutor SnO2 dopado com 5 (mais) % de Sb2O3. O esmalte foi aplicado sobre peças de porcelana a verde e queimado a 1250 ºC. Por microscopia eletrônica de varredura verificou-se que a concentração de pigmento na superfície das amostras é baixa e não influencia a condutividade elétrica. Na fratura, a porcentagem de pigmento ficou próxima de 35%. Assim, a superfície ficou com aspecto visual de ótima qualidade. A resistividade elétrica ocorreu pelo interior do vidrado, obtendo-se valores próximos de 10(4) Ohm.m. Resumo em inglês Semiconductor glazes are employed on electrical insulators to avoid surface discharge under conditions of intense electric fields, providing better performance in polluted environments. Semiconductor enamels are of great interest for electrical insulator coatings to avoid surface discharges, related to large potential differences. This enhances the performance of the insulator under polluted environments. Glazes used in ceramic industries are not conductive. The addition (mais) of conductive oxides to the glaze composition results in a semiconductor enamel. Sb2O3-doped SnO2 was mixed with the enamel in different concentrations. The resulting enamel was applied over green porcelain and fired at 1250 ºC. Scanning electron microscopy characterization was performed and it was verified that the pigment concentration on the surface is low and does not affect the electrical conductivity. The pigment concentration on the fracture surface is approximately 35%. The insulator surface presents a high quality visual aspect and low surface roughness. The electrical resistivity is approximately 10(4) Ohm.m and occurs through the bulk of the glaze.

Scientific Electronic Library Online (Portuguese)

16

Localização de fraturas em rochas graníticas, no município de Capão Bonito-SP, Brasil

Souza Júnior, Abad Oliveira; Porsani, Jorge Luís
2002-08-01

Resumo em português Os métodos GPR-Ground Penetrating Radar e Resistividade Elétrica foram utilizados com o objetivo de localizar zonas de fraturas e o topo da rocha sã, numa pedreira de granito ornamental, localizada próxima à cidade de Capão Bonito, Estado de São Paulo-Brasil. Oito perfis de reflexão GPR e 19 sondagens de velocidade WARR-Wide Angle Reflection and Refraction foram adquiridas utilizando-se as antenas de 25, 50, 100 e 200 MHz. Também foram adquiridas duas SEV's-Sonda (mais) gens Elétricas Verticais. As análises dos perfis GPR permitiram localizar fortes refletores inclinados e subhorizontais, provavelmente relacionados com zonas de fraturas preenchidas com água. Além disso, foram identificadas duas zonas sem reflexões rasas que podem estar relacionadas com intrusões de diques de diabásio, e um refletor hiperbólico relacionado com um matacão. A rocha sã foi identificada a 23 m de profundidade. Os resultados obtidos irão auxiliar o projeto da engenharia de minas orientando o avanço na frente de trabalho. Resumo em inglês Ground Penetrating Radar - GPR and Resistivity methods were used with the objective to detect fracture zones and the top of fresh rock, in ornamental granite mine, located near Capão Bonito City, São Paulo State, Brazil. Eight profiles of reflections GPR and 19 WARR's Soundings were acquired using antennas of 25, 50, 100 and 200 MHz. Two vertical electrical sounding were acquired too. Analysis of GPR's profiles allowed to locate stronger dipping and sub horizontal refle (mais) ctors, probably related with the fractures zones filled with water. Besides, were identified two shadow zones that can be related with intrusions of diabase's dike, and one hyperbolic reflector with a boulder. The fresh rock was identified about 23m of depth. The results obtained probably will go help the project of mine engineering looking forward to advancing of work front.

Scientific Electronic Library Online (Portuguese)

17

Detecção de cavidades em arenitos utilizando gravimetria, eletrorresistividade e GPR/ Detection of cavities in sandstone using gravity, resistivity and GPR methods

Dourado, João C.; Malagutti Filho, Walter; Braga, Antônio C.O.; Nava, Noedir
2001-04-01

Resumo em português Este trabalho mostra os resultados obtidos com a realização de ensaios geofísicos na em áreas de lavra de areia, no município de Descalvado, SP. O objetivo dos ensaios é o de detectar cavidades no interior de arenitos, pertencentes às Formações Pirambóia e Botucatu. Estas cavidades formaram-se com o rebaixamento do lençol freático, necessário para as operações de extração da areia. As técnicas geofísicas utilizadas foram: gravimetria, eletrorresistivida (mais) de (caminhamento elétrico dipolo-dipolo) e radar de penetração no solo (GPR). Na primeira etapa dos trabalhos foram utilizados a gravimetria e a eletrorresistividade em uma bancada onde ocorreu um desmoronamento devido ao abatimento do teto de uma cavidade. Os resultados obtidos com estas duas técnicas foram coerentes pois a gravimetria mostrou baixos gravimétricos indicando uma "ausência de massa" na área de influência da cavidade e o caminhamento detectou um esperado aumento de resistividade elétrica nesta mesma área. Na segunda etapa, com a realização dos ensaios de GPR em uma bancada próxima à anterior, foi possível detectar cavidades por meio das feições hiperbólicas detectadas nos radargramas. Resumo em inglês This paper shows the results of geophysical research in areas of sand exploration near the city of Descalvado, SP, Brazil. The main objective of this research is to detect cavities inside sandstones belonging to the Pirambóia and Botucatu Formations in the Parana sedimentary basin. These cavities were indirectly caused by human activity, i.e., the lowering of the water table for the purpose of sand extraction. The geophysical techniques employed were: gravity, resistivit (mais) y (dipole-dipole electrical profiling) and ground penetrating radar (GPR). In the first stage of the work gravity and resistivity surveys were used to indicate where exists voids due to the collapse of the roof of a cavity. The results obtained with these two techniques were coherent because the gravity showed a "mass absence" in the area of influence of the cavity and the dipole-dipole electrical profiling detected an increase of electric resistivity in this same area. In the second stage, the GPR survey detected the same cavities by means of the hyperbolic features that appear in the radargrams.

Scientific Electronic Library Online (Portuguese)

18

Detecção de contaminação de solo por vinhaça através de análise de dados de eletrorresistividade

Cruz, Juliana Igarashi da; Portugal, Rodrigo de Souza; Lucendo, M. Carmen Hernández; Elis, Vagner Roberto; Fachin, Sergio Junior da Silva; Ustra, Andrea T.; Borges, Welitom Rodrigues
2008-12-01

Resumo em português A vinhaça, resíduo gerado na proporção de 13 litros para cada litro de álcool produzido, possui um alto potencial poluidor dos recursos hídricos subterrãneos e superficiais, causa alterações no comportamento do solo e pode gerar problemas de salinização. Este trabalho objetiva avaliar a eficiência do método da eletrorresistividade para a detecção e mapeamento das anomalias causadas pela disposição inadequada de grandes quantidades de vinhaça em um antigo (mais) tanque de infiltração localizado no Assentamento Sepé-Tiarajú, Região de Ribeirão Preto -SP. O trabalho objetiva também caracterizar o tipo de anomalia inerente ao resíduo no local estudado e diagnosticar sua influência dentro e fora dos limites do tanque. Foram executados onze perfis de tomografia elétrica, arranjo dipolo-dipolo radial e espaçamento entre eletrodos de 10 metros e 5 níveis de investigação. Os ensaios geofísicos mostraram que o método da eletrorresistividade é apropriado para mapear as anomalias decorrentes da disposição de grandes quantidades de vinhaça no solo, apontar suas áreas de influência e concluir que a contaminação extrapola os limites do tanque. A influência da vinhaça pode ser caracterizada por baixos valores de resistividade entre 10 Ohm.m e90 Ohm.m, podendo o seu comportamento ser comparado ao do chorume, que também é bastante condutivo. Resumo em inglês The vinasse, awaste produced in the proportion of 13 liters for each liter of alcohol. It has a high potential of polluting groundwater and superficial water resources, changes the soil behaviour and can also develop sanilization problems. This work aims to evaluate the efficiency of the DC-resistivity method in detecting and mapping anomalies caused by inappropriate disposal of vinasse in an inactive infiltration tank located at Sepé-Tiarajú settlement of landless agri (mais) cultural laborers in the Ribeirão Preto region. Besides, as secondary goals, this work aims to characterize the type of anomaly residue as well as to diagnose its influence inside and outside of the limits of the tank. Eleven electrical resistivity tomography profiles were carried out with the dipole-dipole array, 10m of dipoles length and 5 leveis of investigation The geophysical survey enabled us to conclude that the DC-resistivity method is appropriate for mapping the contamination plume caused by intense vinasse disposal and its influence. It enabled also to conclude that the contamination exceeds the tank limits. The vinasse influence can be characterized by low resistivity values between 10 Ohm.m and 90 Ohm.m and its behavior can be compared with the one of the chorume, which is also conductive.

Scientific Electronic Library Online (Portuguese)

19

Aplicação da técnica de caminhamento elétrico em área contaminada por derivados de petróleo

Moreira, César Augusto; Dourado, João Carlos; Braga, Antonio Celso de Oliveira
2006-09-01

Resumo em português Os métodos geofísicos são ferramentas consagradas de investigação do meio físico, amplamente empregadas no diagnóstico e monitoramento de áreas contaminadas, sempre em conjunto com técnicas diretas de investigação, como análises químicas. Dentre estes, a eletrorresistividade é uma das ferramentas mais comumente utilizadas em estudos de contaminantes em solo e água subterrânea, devido ao elevado contraste de propriedades elétricas entre o meio geológico e (mais) os tipos contaminantes freqüentemente encontrados neste meio, essencialmente constituídos por compostos orgânicos e inorgânicos. Estudos geofísicos em áreas impactadas por derivados de petróleo descrevem anomalias tanto de baixa resistividade quanto de elevada resistividade, confirmadas como fase contaminante por meio de análises químicas. Este aparente contradição pode refletir processos de degradação, associado ao tempo de residência de contaminantes no meio, por meio da geração de subprodutos que alteram as propriedades físicas do meio, principalmente pela dissolução mineral por ação de ácidos orgânicos e pela neoformação de minerais de óxidos e hidróxidos de ferro. Atenuação Natural define uma série de processos físicos, químicos e biológicos que permitem a degradação, dispersão e diluição de contaminantes de forma natural, ou seja, livre da intervenção humana. Este trabalho apresenta a aplicação da técnica de caminhamento elétrico em uma área industrial contaminada por benzeno, tolueno, xileno, 1,2 dicloroetano e sais inorgânicos e discute as alterações físicas do meio contaminado por meio dos resultados obtidos, sob a ótica dos processos de atenuação natural em curso na área de estudos. Resumo em inglês Geophysical methods are useful technics of geological investigation, thoroughly employed to diagnosis and monitoring contaminated areas, in conjunction with direct techniques of investigation such as chemical analyses. Among these, electric resistivity is more usually used in studies of contaminants in soil and groundwater, due to the high contrast of electric properties between the soil and the pollutant types frequently found, essentially constituted of composed organic (mais) and inorganic. Geophysical studies in impacted areas by petroleum products may be describe by anomalies of both low resistivity and high resistivities, confirmed as contaminant by chemical analyses. This apparent contradiction can reflect processes of degradation of the contaminants, directly associated with its residence time in the soil, through the generation of by-products that change the physical properties of the soil and groundwater, principally for the mineral dissolution by action of organic acids and by formation of minerals of oxides and hydroxides minerals. Natural attenuation defines a series of physical, chemical and biological processes that allow the degradation, dispersion and dilution of contaminants in a natural form, in other words, free from human intervention. This paper presents the application of electrical profiling technique in a contaminated industrial area for benzene, toluene, xylene, 1,2 dichloroethene and inorganic salts and it discusses the physical alterations of the contaminated soil through the obtained results, under the optics of the Natural Attenuation in course in the area of study.

Scientific Electronic Library Online (Portuguese)

20

Método da eletrorresistividade aplicado no monitoramento temporal da pluma de contaminação em área de disposição de resíduos sólidos urbanos/ Electrical resistivity method applied in the temporal monitoring of the contamination plume in disposal area of urban solid waste

Bortolin, José Ricardo Melges; Malagutti Filho, Walter
2010-12-01

Resumo em português Este trabalho apresenta os resultados do monitoramento temporal da pluma de contaminação do aterro controlado de Rio Claro, São Paulo, por meio do método da eletrorresistividade, que consistiu na comparação dos resultados de várias seções de imageamento elétrico, executados nos mesmo locais, nos anos de 1999 e 2008. Zonas de baixa resistividade, com valores menores ou iguais a 50 Ω.m, foram associadas à contaminação por chorume. Desse modo, foi possível (mais) identificar dois sentidos do fluxo da pluma: (1) em direção ao sul, e (2) em direção ao oeste. Nas seções de 2008, a pluma de contaminação apresentou-se mais extensa e profunda do que em 1999. De forma complementar, as sondagens elétricas verticais aferiram a profundidade do nível freático e o sentido do fluxo d'água, subsidiando a interpretação dos imageamentos. Resumo em inglês This paper shows the results of a periodical monitoring of the contamination plume of a controlled landfill in Rio Claro, São Paulo, Brazil, using electrical resistivity geophysical method. The monitoring consisted on comparing the results of several electrical sections, performed at the same location, in the years of 1999 and 2008. Low resistivity zones, with values lower than or equal to 50 Ω.m, have been associated to contamination by leachate. Thus, it was possi (mais) ble to identify two directions for the contamination flows: (1) toward south, and (2) toward west. In the results of 2008, the contamination plume was more extensive and profound than in 1999. The vertical electrical soundings indicated the water table depth and the water flow directions, helping the interpretation of results of the electrical profiles.

Scientific Electronic Library Online (Portuguese)

21

Produção e caracterização de filmes finos de óxido de zinco intrínsecos e dopados com alumínio e boro/ Production and characterization of zinc oxide thin films intrinsic and doped with aluminum and boron

Dias, Claudio André Chagas Martins; Paes Júnior, Herval Ramos
2006-09-01

Resumo em português Filmes finos de óxido de zinco intrínsecos (ZnO) e dopados com Alumínio (ZnO:Al) e Boro (ZnO:B) foram depositados por spray-pirólise sobre substratos de vidro. Foi estudada a influência de parâmetros como a concentração de dopante, temperatura de substrato (TS) e processamento térmico sob vácuo sobre as propriedades estruturais, óticas e elétricas dos filmes visando sua aplicação como óxido condutor transparente. Foram obtidos valores de resistividade elét (mais) rica de 1, 21 x 10-2 e 6,97x 10-3 W.cm para filmes de ZnO:Al (1% at. - Ts= 550ºC) e ZnO:B (0,5% at. - Ts= 500ºC) tratados termicamente, respectivamente, e uma transmitância ótica de 48%. O cálculo das figuras de mérito correspondentes indicou uma ligeira superioridade do filme ZnO:B. De modo geral, o tratamento térmico provocou uma redução de 3 a 4 ordens de grandeza no valor da resistência de folha dos filmes. A energia de GAP ótico situou-se entre 3,00 e 3,30 eV. Resumo em inglês Intrinsic (ZnO), Al-doped (ZnO:Al) and B-doped (ZnO:B) thin films were deposited by spray-pyrolysis on glass substrates. The influence of parameters such as doping concentration, substrate temperature (Ts) and thermal processing under vacuum on the structural, optical and electrical properties of the films, was studied with the purpose to consider their application as transparent conductive oxides. Electrical resistivity values of 1.21 x 10-2 and 6.97 x 10-3 omega.cm were (mais) obtained for ZnO:Al (1 at.% - Ts = 550°C) and ZnO:B (0,5 at.%. - Ts = 500°C) heat treated films, respectively, and an optical transmittance of 48%. The value of the figure of merit of these films indicated a light superiority of the ZnO:B film. In general, the heat treatment decreases the sheet resistance of the films from 3 to 4 orders of magnitude. The energy of optical GAP varied from 3,00 to 3,30 eV.

Scientific Electronic Library Online (Portuguese)

22

Delimitação do topo de aqüífero na região de Porto Seguro - Bahia através da inversão de sondagens elétricas verticais/ Definition of the aquifer top in the region of Porto Seguro - Bahia from the inversion of vertical electrical sounding data

Monteiro, Alexandre C.; Porsani, Milton J.
2001-12-01

Resumo em português O presente trabalho compreendeu estudos geofísicos conduzidos com o método da eletrorresistividade na região de Porto Seguro (BA), que tiveram o objetivo de localizar o aqüífero mais promissor para a exploração de água subterrânea naquela região. Os trabalhos recobriram uma área de aproximadamente 60km² situada imediatamente ao norte de Porto Seguro. A área pesquisada insere-se num contexto geológico de ambiente sedimentar Terciário (Formação Barreiras) e (mais) Quaternário (cordões litorâneos). Foram realizadas 60 sondagens elétricas verticais (SEVs) utilizando o arranjo Schlumberger. Destas, 14 foram realizadas para reconhecimento regional; 36 localizaram-se dentro da área de interesse e 10 distribuiram-se ao longo de um perfil regional ligando as cidades de Eunápolis e Porto Seguro. Estas últimas foram realizadas com o objetivo de delinear o topo do embasamento cristalino entre aquelas cidades. Para a interpretação quantitativa das SEVs foi desenvolvido um programa Fortran baseado no método de inversão que utiliza a técnica da inversão linearizada com reponderação múltipla dos desvios (ILRMD). Este método foi testado na inversão de SEVs sintéticas e em seguida aplicado para inversão das SEVs obtidas nos trabalhos de campo. Os resultados demonstraram que o método de ILRMD é mais robusto e eficaz comparado ao método de inversão linearizada governado pela norma L² ou L¹. Para auxiliar a interpretação foram utilizados dados disponíveis de perfis litológicos de poços perfurados na região. Utilizando-se as estimativas de espessura e resistividades de subsuperfície, obtidas através das inversões das SEVs, foram construídas seções geoelétricas. A interpretaçcão destas seções permitiu determinar o aqüífero de interesse para a exploração de água subterrânea naquela região. Este é formado predominantemente por arenito saturado com água doce e ocupa a porção centro-norte da área com o topo na profundidade a cerca de 80m e espessura não inferior a 70m. Tal aqüífero representa a melhor opção para a captação de água subterrânea no município de Porto Seguro. Resumo em inglês This paper comprises geophysical studies carried out with the resistivity method in the Porto Seguro region, in the state of Bahia (Brazil). The objective was to find the main aquifer of that region. The work was performed on a area of approximately 60 km² located north of the Porto Seguro city. The studied area has sedimentary units with Tertiary (Formação Barreiras) and Quaternary (coastal shore) ages. Sixty vertical electrical soundings (VES) were performed using th (mais) e Schlumberger array: 14 for regional reconnaissance; 36 for detailed study and 10 in a profile between the cities of Eunápolis and Porto Seguro. The VES in the regional profile were carried out to define the basement topography between these cities. A Fortran program was written for the quantitative interpretation of the VES, based on the method that uses the linearized inversion with multiple weight for the deviations (LIMWD). This proposition was tested on synthetic VES data and then it was used with field data. The results showed that this method is more stable and powerful than the traditional linearized inversion method which uses L¹ and L² fixed norms. The available information about well drilling data of the region was used to aid the interpretation. Geoelectrical sections were drawn from the inverted results of the thickness and resistivity of the layers. The interpretation of these sections provided the definition of the main aquifer for ground water exploitation in this region. This aquifer is confined to saturated sandstone layer in the mid-north portion of the area at about 80 m deep and an average thickness of 70 m. This aquifer represents the best option for ground water exploitation to supply the city of Porto Seguro.

Scientific Electronic Library Online (Portuguese)

23

O método magnetolúrgico aplicado à Bacia do São Francisco, Minas Gerais/ The magnetotelluric method applied in the São Francisco Basin, Minas Gerais

Porsani, Jorge L.; Fontes, Sérgio L.
2001-08-01

Resumo em português Foram realizadas 43 sondagens magnetotelúricas, totalizando oito seções, na parte central da bacia sedimentar do São Francisco, região Norte do estado de Minas Gerais. Este estudo visou mapear a estrutura geoelétrica da bacia. O levantamento foi superposto a 10 linhas sísmicas, cobrindo 11.000 km² de área. O espaçamento entre as sondagens foi irregular e a freqüência utilizada variou de 0,001 até 400 Hz, permitindo investigar até 60 km de profundidade. Os da (mais) dos foram corrigidos do efeito de deslocamento estático através da mediana da resistividade do primeiro condutor. Utilizou-se um invariante do tensor impedância para interpretar a estrutura geoelétrica da bacia. Apresenta-se neste trabalho o resultado de uma seção geoelétrica obtida através de inversão 1D. Foi identificada uma seqüência de horizontes condutivos e resistivos, correspondentes ao pacote sedimentar e o topo do embasamento geoelétrico, que caracterizam a bacia do São Francisco. Além disso, identificou-se uma zona condutiva e outra resistiva a profundidades crustais. Os resultados apresentaram uma boa concordância com os dados sísmicos e gravimétricos, enquanto a concordância com o perfil de eletrorresistividade do poço existente na área de investigação foi apenas razoável. Resumo em inglês Forty-three magnetotelluric (MT) soundings were undertaken along eight profiles at the central portion of the São Francisco Sedimentary Basin, northern region of Minas Gerais State. The study aimed at the mapping of the geoelectrical structure of the basin. The MT profiles were deployed along ten seismic lines covering 11,0000 km² of total area. The MT soundings were irregularly spaced and covered the frequency range from 0.001Hz to 400 Hz, probing the electric structur (mais) e from the surface to a maximum depth of 60 km. The MT data affected by static shift were corrected by fixing the resistivity value (given by the median) of the first observed conductor. The geoelectric interpretation was based on a rotationally invariant impedance response function. We identified a sequence of conductive and resistive layers, which are related to the sedimentary sequence observed in the São Francisco Basin and its crystalline basement. The results show good agreement with seismic and gravimetric data while showing just a fair agreement with available electrical well log information.

Scientific Electronic Library Online (Portuguese)

24

O emprego de métodos geofísicos na fase de investigação confirmatória em cemitérios contaminados/ Application of geophysical methods in the confirmatory investigation phase in contaminated cemeteries

Silva, Robson Willians da Costa; Malagutti Filho, Walter
2009-09-01

Resumo em português Dentro do gerenciamento de áreas contaminadas, a aplicação de métodos geofísicos, em estudos de área contaminada, constitui uma metodologia confirmatória. Este procedimento - mais precisamente o método da eletrorresistividade por meio das técnicas da sondagem elétrica vertical e imageamento elétrico - foi aplicado no cemitério de Vila Rezende, em Piracicaba, São Paulo, para investigar e mapear a contaminação do cemitério por necrochorume. Os resultados ind (mais) icam uma profundidade do nível freático entre 3,1 e 5,1 m, com duas direções de fluxo subterrâneo, uma a SW e outra a SE. Tanto as prováveis plumas de contaminação, que têm as mesmas direções de fluxo subterrâneo, quanto as anomalias condutivas verificadas nas seções geoelétricas confirmam as suspeitas de contaminação na área. Resumo em inglês Inside of the administration of contaminated areas, the application of geophysical methods, in studies of contaminated area, constitutes a confirmatory methodology. This procedure - more precisely the electrical resistivity method through the techniques of the vertical electric sounding and electrical imaging techniques, was applied at Vila Rezendeâ€TMs cemetery, Piracicaba, São Paulo, Brazil, to investigate and to map the contamination of the cemetery for necrochorume (mais) . The results indicate a depth of water table among 3.1 and 5.1 m, with two flow directions, being one to SW and another to SE. So the probable contamination plumes, that have the same directions of underground flow, as for the conductive anomalies verified at the geoelectrics sections confirm the suspicions of contamination in the area.

Scientific Electronic Library Online (Portuguese)

25

Magnetorresistência colossal em La5/8-yPr yCa3/8MnO3/ Magnetoresistance in La5/8-yPr yCa3/8MnO3

Masunaga, S. H.; Jardim, R. F.
2007-09-01

Resumo em português Amostras policristalinas de La5/8-yPr yCa3/8MnO3, 0 0,35 também mostram uma transição para o estado de ordenamento de carga/orbital T OC. Uma análise das (mais) medidas de ro(T, H) sugere a coexistência de pelo menos duas fases distintas nesses materiais: uma ferromagnética-metálica FMM e uma segunda, com ordenamento de carga/orbital e comportamento isolante OCI. Os resultados também permitem concluir que as frações volumétricas dessas fases podem ser manipuladas, alterando-se parâmetros termodinâmicos como T e H. A magnetorresistência MR(T), determinada através das medidas de ro(T, H), foi observada ocorrer em uma larga faixa de temperatura e em todas as amostras pertencentes à série. Amostras ricas em Pr (y > 0,35) revelam um efeito de magnetorresistência colossal amplificado devido à coexistência e competição das FMM e OCI cujas frações volumétricas podem ser alteradas via mudança da temperatura e aplicação de um campo magnético externo. Resumo em inglês Polycrystalline samples of La5/8-yPr yCa3/8MnO3; 0 0.35 a transition to a charge and orbital-ordered state was also observed. The rho(T, H) data analyses suggest the coexistence of at least (mais) two ordered phases in these samples: a ferromagnetic metallic phase FMM and a charge and orbital-ordered insulating COI phase.The data also indicate that the volume fraction of these phases can be changed by the variation of thermodynamic parameters like temperature T and magnetic field H. The magnetoresistance MR(T) determined from rho(T, H) data were observed in a large temperature range for all samples. In addition, samples with y > 0.35 were found to display a pronounced colossal magnetoresistance effect due to a severe competition between FMM and COI coexisting phases.

Scientific Electronic Library Online (Portuguese)

26

Geofísica aplicada ao estudo de fluxos da água no solo/ Geophysics applied to study of water flow in the soil

Morais, Fernando; Bacellar, Luis de Almeida Prado
2010-04-01

Resumo em português A eletrorresistividade vem sendo bastante aplicada em estudos que buscam compreender como se dá o fluxo de água no solo e consequentemente a recarga de aquíferos. O presente trabalho teve por objetivo avaliar a interferência de algumas propriedades físicas do solo na determinação da frente de saturação predita com o uso da eletrorresistividade e comparar como se dá a percolação na zona não-saturada, observando a variação de perfis de resistividade obtidos e (mais) m um intervalo de tempo determinado. Os experimentos foram conduzidos em solos da região sudeste do complexo de rochas do embasamento cristalino (Complexo Bação), no interior do Quadrilátero Ferrífero, centro-sul do Estado de Minas Gerais, Brasil. Foram selecionadas duas áreas que se distinguem pelas características geomorfológicas. A primeira, em encosta com formas côncavas em planta e em perfil, com predomínio de argissolos; a segunda, em encosta com forma convexa em planta e perfil, com predomínio de solos bem desenvolvidos (latossolos). Os resultados mostraram que o método da eletrorresistividade se mostrou eficiente para a delimitação da frente de saturação e avaliação da recarga mesmo em se tratando de diferenças sutis nas propriedades hídricas do solo. Foi possível ainda estabelecer que na feição geomorfológica em forma convexa (nose) a percolação se dá de maneira mais rápida que na de forma côncava (hollow). Resumo em inglês The electrical resistivity is common used in studies that intents to understand as occur the flow of water in soil and consequently as occur the groundwater recharge. The main goal of this paper is to evaluate the interference of some physical properties of the ground in the determination of the front of saturation predicted with the use of the electrical resistivity and to compare as if of the a percolating in the vadose zone, observing the variation of gotten profiles o (mais) f resistivity in an interval of definitive time. Experiments were conducted in soils of southeastern complex crystalline rocks of reliance (Bação complex), within the Quadrilátero Ferrífero, Centro-Southern State of Minas Gerais, Brazil. For this experiment it was chosen two different areas by geomorphologic features. The first one is hollow on the slippery slope, with the predominance of lixisols; the second one is nose on the slippery slope, with well-developed topsoil prevalence (ferralsols). The results showed that the electrical resistivity method proved efficient for the delimitation of saturation and evaluation reloading even when it comes to subtle differences in the properties of soil water. It was also possible to establish that in the nose slope percolation is faster than in the hollow.

Scientific Electronic Library Online (Portuguese)

27

Estruturas geoelétrica e hidroquímica do sistema aquífero cristalino da bacia do alto rio Curaçá, semi-árido da Bahia/ Geoelectrical and hydrochemical structures of the crystalline aquifer system of the high Curaçá river basin, semi-arid of Bahia, Brazil

Lima, Olivar Antonio Lima de
2010-09-01

Resumo em português Neste trabalho se analisa uma estratégia geofísico-hidrogeológica proposta para explorar racionalmente a água subterrânea armazenada nos terrenos cristalinos semi-áridos, como aqueles da bacia do alto rio Curaçá, Bahia. Num estudo integrado, três principais problemas foram considerados e resolvidos. O primeiro envolveu a proposição de um modelo hidrogeológico conceitual para representar o armazenamento e a transmissão de água no sistema aquífero da área. U (mais) sando informações geofísicas aéreas e terrestres com dados geológicos de testemunhos de sondagens, propõe-se um modelo consistindo de: (i) uma cobertura aluvionar e de saprólitos, com cerca de 20 a 30 m de espessura e que se estende, continuamente, ao longo da planície do rio Curaçá e de seus tributários; e (ii) zonas largas e extensas de densos e profundos fraturamentos subverticais, geralmente abertos e que formam faixas com mais de 500 m de largura e profundidades maiores que 300 m, separadas entre si por ombreiras de rocha cristalina mais fechada. O segundo consistiu em aperfeiçoar um procedimento geoelétrico capaz de imagear, com boa resolução espacial, esses complexos reservatórios subterrâneos de água. Assim, um esquema de imageamento bidimensional de IP-resistividade foi realizado através de um adensamento lateral da amostragem geoelétrica por sondagens verticais e de um aumento na profundidade de investigação, usando uma instrumentação mais potente. O terceiro foi pesquisar e explicar os mecanismos e processos responsáveis pela alta salinização da água observada em poços perfurados nesse sistema. Usando um modelo simplificado de fluxo bidimensional estacionário, num aquífero livre, homogêneo e isotrópico, se sugere que a salinização se deve, principalmente, ao quase-contínuo e intenso processo de evapo-transpiração, característico das zonas semi-áridas. Tal processo atua sobre um sistema de circulação hidráulica controlado pela topografia do terreno, o qual se processa em células de diferentes dimensões laterais e profundidades, sendo que é nas mais rasas que se concentram os sais. Resumo em inglês In this work we discuss a geophysical-hydrogeological strategy proposed to explore rationally the groundwater stored in the semi-arid terrains, such as those of the upper Curaçá river basin, Bahia. Three main subjects were considered and solved in this study. The first one was to develop a conceptual geohydrologic model to represent the water storage and transmission within the aquifer zones of the area. Based on surface and aero-geophysical information and on geologica (mais) l data obtained in deep cored mining-wells we propose the model to consist of: (i) a thick layer of alluvial deposits and weathered rocks (saprolites) having up to 30 m thickness, covering almost continuously the Curaçá river plain and those of their tributaries; and (ii) large and wide belts of densely fractured rocks, laterally and vertically alternating with zones of impervious crystalline basement. These belts of open, subvertical fracturing may reach more than 500 m in width and depths larger than 300 m. The second was to optimize a geoelectrical procedure capable of imaging, with good spatial resolution, these complexes underground reservoirs. Thus, a two-dimensional scheme of IP-resistivity imaging was performed with a closely spaced association of deep vertical electrical soundings. The third was to search and explain the mechanisms and processes responsible for the high water salinization in the wells drilled in this system. Based on a simplified model for a steady-state, two-dimensional flow of water in a water-table homogeneous and isotropic aquifer, we suggest this salt concentration process is mainly due to the intense and almost continuous evapo-transpiration, that characterizes the semi-arid lands. This process acts over a hydraulic circulating system controlled by the terrain topography. The circulation cells have different sizes and depth of propagation, the salt accumulation being concentrated in the smaller cells.

Scientific Electronic Library Online (Portuguese)

28

Emprego do método da eletrorresistividade no estudo da contaminação subterrânea do cemitério municipal de Vila Rezende, Piracicaba - SP

Silva, Robson Willians da Costa; MalaguttiFilho, Walter; Moreira, César Augusto
2009-09-01

Resumo em português Neste trabalho são apresentados os resultados da aplicação do método da eletrorresistividade para delimitação de áreas potencialmente impactadas por necrochorume no cemitério municipal de Vila Rezende, Piracicaba - SP. Os resultados indicam uma profundidade do nível freático entre 3,1 e 5,1 m na época de estiagem, com duas direções de fluxo subterrâneo: uma a SW e outra a SE. Indicam ainda condições desfavoráveis, em subsuperfície, para percolação do n (mais) ecrochorume, mas favoráveis ao fenômeno de saponificação dos cadáveres. As prováveis plumas de contaminação têm as mesmas direções do fluxo subterrâneo. A provável pluma a SE se prolonga para fora dos limites do cemitério. A localização das anomalias condutivas e das prováveis plumas de contaminação demonstrou que a contaminação tem ligação com a profundidade do nível freático e com o tempo de sepultamento. O método da eletrorresistividade demonstrou ser um instrumento importante para avaliação da qualidade ambiental em cemitérios. Resumo em inglês This paper presents the results of the application of electrical resistivity method in the delineation of areas potentially impacted by necrochorume in Vila Rezende's municipal cemetery, Piracicaba - SP (Brazil). The results indicate a depth of water table among 3.1 and 5.1 m in drought, with two flow directions: a SW and another to the SE. Also indicate unfavorable conditions in subsurface to percolation of necrochorume but favorable to the corpses phenomenon saponificat (mais) ion. The probable contamination plumes have the same directions of the groundwater flow. The probable plume is prolonged to out of the cemetery. The location of the conductive anomalies and likely contamination plumes demonstrated that the contamination is linked with the depth of water table level and the burial time. The electrical resistivity method has proved to be an important tool for assessing the environmental quality in cemeteries.

Scientific Electronic Library Online (Portuguese)

29

Decomposição de resíduos sólidos domiciliares e variações na resistividade e cargabilidade

Moreira, César Augusto; Braga, Antonio Celso de Oliveira
2009-09-01

Resumo em português A geofísica aplicada em estudos ambientais é uma alternativa viável e promissora diante da demanda crescente por novas técnicas de investigação, essencialmente na caracterização e monitoramento de áreas contaminadas. Este trabalho apresenta os resultados de aplicação dos métodos de Eletrorresistividade e Polarização Induzida, na análise da área de percolação de chorume proveniente de aterro de resíduos sólidos dispostos em valas com datas de fechamento (mais) programado.Os resultados sugerem uma associação entre anomalias de alta cargabilidade em valas de resíduos fechadas recentemente, enquanto que as anomalias de baixa resistividade independem da idade de fechamento das valas. As áreas com alta cargabilidade provavelmente estão relacionadas à precipitação de Ferro, dissolvido por ataque do chorume no solo e nos materiais metálicos presentes nos resíduos. Resumo em inglês The applied geophysics in environmental studies is a viable and promising alternative forward of the crescent demand for new techniques of investigation, essentially in the characterization and monitoring of contaminated areas. This paper presents the results of the application of the Electrical Resistivity and Induced Polarization methods, in analysis of the area of leachate percolation from municipal solid waste landfill, in ditches with dates of programmed closing. The (mais) results suggest an association among high chargeability anomalies and residues ditches closed recently, while the low resistivity anomalies they are independent of the age of closing. The areas with high chargeability are probably related to the precipitation of iron, dissolved for attack of the leachate in soil and metallic materials present in the residues.

Scientific Electronic Library Online (Portuguese)

30

Comportamento elétrico a alta temperatura de termistor cerâmico alfa-Fe2O3 com coeficiente de temperatura negativo/ High temperature electrical behavior of alpha-Fe2O3 ceramic thermistor with negative temperature coefficient

Lanfredi, S.; Grosso, R. L.; Antunes, A. C.; Antunes, S. R. M.; Nobre, M. A. L.
2008-12-01

Resumo em português O comportamento elétrico da cerâmica densa de α-Fe2O3, sintetizada pelo método Pechini, foi investigado por espectroscopia de impedância na faixa de freqüência de 5 Hz a 13 MHz. As medidas foram realizadas entre 298 K e 623 K ao ar. A evolução da resistividade do grão com a temperatura mostra um comportamento característico de termistor com coeficiente de temperatura negativo. A condutividade do grão em função da temperatura obedece a lei de Arrhenius co (mais) m energia de ativação aparente 0,66 eV. A permissividade dielétrica em função da freqüência mostra uma dispersão em freqüências menores que 10 kHz, a qual aumenta com o aumento da temperatura. De forma similar, o parâmetro tangente de perdas (tg δ) exibe uma forte dispersão a baixa freqüência e alta temperatura, em torno de 573 K. Uma diminuição na magnitude das perdas ocorre na região de altas freqüências, acima de 10(4) Hz. Um mecanismo de condução do tipo hopping é discutido. Resumo em inglês The electrical behavior of α-Fe2O3 dense ceramic, synthesized by Pechini method, was investigated by impedance spectroscopy in the frequency range from 5 Hz to 13 MHz. Electrical measurements were carried out from 298 K to 623 K in air. The evolution of the resistivity as a function of temperature shows a thermistor behavior with negative temperature coefficient. The grain conductivity as a function of temperature follows the Arrhenius law exhibiting an apparent acti (mais) vation energy for the electrical conduction process equal to 0.66 eV. The dielectric permittivity as a function of frequency and temperature shows a dispersion phenomenon at frequencies lower than 10 kHz, which increase with temperature increasing. The tangent loss tan δ shows a strong dispersion at low frequency and high temperature, around 573 K. A decrease of the loss magnitude occurs at frequencies > 10(4) Hz. A conduction mechanism of the hopping type is discussed.

Scientific Electronic Library Online (Portuguese)

31

Aplicação de métodos geofísicos no monitoramento de área contaminada sob atenuação natural/ Applications of geophysical methods in monitoring contaminated area under natural attenuation

Moreira, César Augusto; Braga, Antonio Celso de Oliveira
2009-06-01

Resumo em português Estudos geofísicos em áreas impactadas por derivados de petróleo descrevem anomalias tanto de baixa quanto de elevada resistividade, confirmada como fase contaminante por meio de análises químicas. Esta aparente contradição pode refletir processos de degradação, associada ao tempo de residência de contaminantes no meio, por meio da geração de subprodutos que alteram as propriedades físicas do meio, principalmente pela dissolução mineral por ação de ácido (mais) s orgânicos e pela neoformação de minerais de óxidos e hidróxidos de ferro. Este trabalho apresenta resultados da aplicação do método de eletrorresistividade e polarização induzida em uma área industrial contaminada por benzeno, tolueno, xileno, 1,2 dicloroetano e sais inorgânicos, em processo de atenuação natural. Os resultados indicam a neoformação mineral no centro e nas adjacências da área contaminada, conforme sugerem as alterações apontadas nos parâmetros físicos medidos. Resumo em inglês Geophysical studies in impacted areas by petroleum products may be described by anomalies of both low and high resistivity, confirmed as contaminant by chemical analyses. This apparent contradiction can reflect processes of contaminants degradation, directly associated with its residence time in the soil, through the generation of by-products that change the physical properties of the soil and groundwater, principally for the mineral dissolution by action of organic acids (mais) and by neoformation minerals of oxides and hydroxides minerals. This paper presents the application of electrical resistivity and induced polarization methods in a contaminated industrial area for benzene, toluene, xylene, 1,2 dichloroethene and inorganic salts, in natural attenuation process. The results indicated the mineral neoformation in the center and adjacencies of contaminated area, as it suggested the alterations in physical parameters measured.

Scientific Electronic Library Online (Portuguese)

32

Análise integrada de dados de sensoriamento remoto, geologia e geofísica no estudo de aqüífero fraturado, Lindóia - SP

Madrucci, Vanessa; Taioli, Fabio; Araújo, Carlos César de
2005-12-01

Resumo em português Este trabalho apresenta um estudo de detalhe no aqüífero fraturado na região de Lindóia, Estado de São Paulo. A partir do estudo regional de favorabilidade de ocorrência de água subterrânea definiu-se a área de estudo a qual foi mapeada como excelente favorabilidade. O estudo de detalhe consistiu no mapeamento de fraturas em fotografias aéreas (escala 1:25.000) e realização de levantamento geofísico de eletrorresistividade (caminhamento elétrico e sondagem e (mais) létrica vertical). Realizou-se a inversão dos dados geofísicos e a análise integrada desses dados com os dados geológicos de campo, dados de poços, fontes e fraturas mapeadas em fotografias aéreas. Os resultados mostram que foi possível otimizar os trabalhos de campo com a obtenção de resultados satisfatórios em relação à definição de locais mais favoráveis para a locação de poços. Resumo em inglês Detecting groundwater in fractured aquifers is always a difficult task. This paper presents the detailed study of a fractured aquifer in Lindóia region, São Paulo, Brazil. The study area was selected after a regional study analyzing the favorability for occurrence of groundwater which classified the area as being of excellent groundwater favorability. The study consisted on fractures mapping based on aerial photographs (scale 1:25,000) and geoelectrical survey (vertical (mais) electrical sounding and resistivity imaging). The geophysical data was processed, inverted and analyzed by using geological field data, wells data, springs data and fractures mapped using aerial photographs. The results show that it was possible to define favorable locations for the wells and optimize field work.

Scientific Electronic Library Online (Portuguese)