Sample records for currents electric
from WorldWideScience.org

Sample records 1 - 8 shown.



1

Demonstração didática da interação entre correntes elétricas/ Didactic demonstration of the interaction between electric currents

Souza Filho, M.P.; Chaib, J.P.M.C.; Caluzi, J.J.; Assis, A.K.T.
2007-01-01

Resumo em português Apresentamos a primeira experiência crucial de Ampère mostrando a interação entre dois fios metálicos conduzindo correntes elétricas. Discutimos sua importância na história da física. Descrevemos uma reprodução moderna dos procedimentos e observações de Ampère com materiais de baixo custo. Resumo em inglês We present the first crucial experiment by Ampère that shows the interaction of two metallic wires carrying steady currents. We discuss its importance in the history of physics. We also present a modern reproduction of the procedures and observations of Ampère with low cost materials.

Scientific Electronic Library Online (Portuguese)

2

Determinação dos limiares de percepção sensorial e de resposta motora nas diferentes fases do ciclo menstrual/ Determination of sensory perception and motor response thresholds in different phases of the menstrual cycle

Barbosa, MB; Montebelo, MIL; Guirro, ECO
2007-12-01

Resumo em português OBJETIVO: Identificar a variação de percepção sensorial e resposta motora nas diferentes fases do ciclo menstrual (CM). MÉTODO: 30 mulheres com idade entre 18 e 40 anos (23,7 ± 3,60), com índice de massa corporal entre 18,5 e 25kg/m² (21,15 ± 2,32) e CM entre 21-35 dias participaram do estudo. Utilizou-se um gerador de pulso com correntes elétricas pulsadas, freqüência de 50Hz e fases variando em 20 (B20), 50 (B50), 100 (B100), 300 (B300), 500 (B500), 1000 (B1 (mais) 000) e 3000µs (B3000). O limiar de percepção sensorial (LPS) foi identificado como a primeira sensação de corrente ao aumento da intensidade e o limiar de resposta motora (LRM) como a mínima contração muscular detectada. Realizaram-se cinco coletas, sendo uma em cada fase: fase 1- menstrual (F1), fase 2- proliferativa (F2), fase 3- ovulatória (F3), fase 4- lútea (F4) e fase 5- pré-menstrual (F5). A análise dos dados constou do teste de Friedman seguido do teste de Rank, realizados no programa Bioestat 4.0®, com nível de significância de 5%. Resultados: O LPS foi menor na F5 quando comparado às demais fases menstruais, para as correntes B20, B300, B500, B1000, B3000. Para o LRM houve diferença nas correntes B20, B50, B500 e B1000 entre todas as fases com a F5; na corrente B100, entre a F1 e F5; e nas correntes B300 e B3000 entre F1, F2 e F3 com a F5. CONCLUSÕES: O limiar de percepção sensorial e a resposta motora variaram sistematicamente através das fases do CM, influenciando o comportamento sensório-motor. Resumo em inglês OBJECTIVE: To identify the variation of sensory perception and motor response in the different phases of the menstrual cycle. METHOD: Thirty women aged 18 to 40 years old (23.7 ± 3.60), with body mass index between 18.5 and 25kg/m² (21.15 ± 2.32) and menstrual cycle of 21-35 days, participated in this study. A pulse generator was used, with pulsed electric current frequency of 50Hz and variable phases of 20 (L20), 50 (L50), 100 (L100), 300 (L300), 500 (L500), 1000 (L10 (mais) 00) and 3000µs (L3000). The threshold of sensory perception (TSP) was identified as the first sensation of increased current intensity and the threshold of motor response (TMR) as the minimum muscle contraction detected. Five collections were done, at each of the following phases: phase 1- menstrual (P1), phase 2- follicular (P2), phase 3- ovulatory (P3), phase 4- luteal (P4) and phase 5- premenstrual (P5). The data analysis consisted of the Friedman test followed by the Rank test, carried out in the BioStat 4.0® software, with a significance level of 5%. RESULTS: The TSP was lower in P5 than in the other menstrual phases, for the L20, L300, L500, L1000 and L3000 currents. For the TMR, there was difference in the L20, L50, L500 and L1000 currents between P5 and all other phases; in the L100 current, between P1 and P5; and in the L300 and L3000 currents for P1, P2 and P3 versus P5. CONCLUSIONS: The thresholds of sensory perception and motor response varied systematically through the phases of the menstrual cycle, thus influencing motor-sensory behavior.

Scientific Electronic Library Online (Portuguese)

3

Princípios físicos da estimulação magnética transcraniana/ Magnetic stimulation: physical and technical aspects

Martins, Marcos Nogueira
2004-01-01

Resumo em português Este trabalho descreve brevemente os principais aspectos da física e da tecnologia envolvidos no processo de estimulação magnética. Apresenta a lei de indução de Faraday e descreve como um pulso de campo magnético, intenso e rápido, tem condições de gerar campos elétricos localizados, adequados à produção de correntes elétricas em determinados tecidos. Discute-se, também, como a geometria da bobina e o perfil temporal dos pulsos de corrente que a percorrem, são usados para otimizar a distribuição e intensidade dos campos elétricos induzidos. Resumo em inglês This work presents a brief discussion of the physics and technology of magnetic stimulation. From Faraday's law of induction we describe how a fast and intense pulse of magnetic field may produce localized electric fields, suitable to generate electric currents in certain tissues. We discuss how the coil geometry, and the time profile of the pulse of current may be used to optimize the distribution and intensity of the induced electric fields.

Scientific Electronic Library Online (Portuguese)

4

Fulguração como causa de morte em bovinos no Estado do Rio Grande do Sul/ Lightning strike as a cause of death in cattle in Rio Grande do Sul

Watanabe, Tatiane T.N.; Ferreira, Hugo H.; Gomes, Danilo C.; Pedroso, Pedro M.O.; Oliveira, Luiz G.S.; Bandarra, Paulo M.; Antoniassi, Nadia A.B.; Driemeier, David
2010-03-01

Resumo em português Fulguração é a morte de animais pela ação de correntes elétricas atmosféricas ou raios durante tempestades. Quatro bovinos provenientes de dois rebanhos foram encontrados mortos nas proximidades de árvores de Eucalyptus sp. imediatamente após registros de tempestades no Estado do Rio Grande do Sul. Nos locais haviam árvores com linhas de queimadura recente no tronco, cascas parcialmente soltas, além de restos de galhos e folhas espalhados sob as copas das árvo (mais) res. Não foram encontradas lesões macroscópicas e microscópicas significativas, nem indícios de enfermidades tóxicas ou infecciosas. Tais achados sugerem morte súbita por fulguração nos bovinos. Resumo em inglês Lightning strike may cause sporadic deaths of animals that have been exposed to high-voltage electric currents during thunderstorms. Four healthy adult cattle from two herds were found dead next to eucalypt trees immediately after storms in Rio Grande do Sul, Brazil. There were recent burns and loose barks on the trunks of the trees, apart numerous branches and leaves scattered on the ground under the canopy of the trees. No gross or microscopic lesions were observed. In (mais) addition, there was no evidence of any toxic or infectious disease. These findings suggest that lightning strike caused the death of those animals.

Scientific Electronic Library Online (Portuguese)

5

Simulação numérica do crescimento da lentilha de solda obtida pelo processo de soldagem a ponto por resistência elétrica no aço inox AISI 304/ Numerical simulation of nugget growth for resistance spot welding in stainless steel AISI 304

Molenda, Carlos Henrique de Andrade; Paris, Aleir Antônio Fontana de; Limberger, Inácio da Fontoura; Silva, Rogério Brittes da; Oliveira, Leandro Marin de; Righi, Luiz Antônio
2010-12-01

Resumo em português O crescimento das lentilhas de solda obtidas pelo processo de soldagem a ponto por resistência elétrica em chapas de aço inoxidável AISI 304 foi analisado através de simulação numérica com o método de elementos finitos, sendo utilizado para essa finalidade o programa comercial ANSYS. O modelo matemático utilizado considerou: acoplamento entre os campos elétricos e térmicos em regime transiente; a variação das propriedades elétricas e térmicas do aço AISI (mais) 304 com a temperatura e condições de contorno térmicas de convecção. A geometria tridimensional analisada, axissimétrica, permitiu a simplificação para uma geometria bidimensional. Os resultados obtidos com o modelo foram comparados com resultados experimentais apresentados na literatura. Foram consideradas espessuras de chapas de 1, 2 e 3 mm, e diferentes diâmetros de face para os eletrodos. As simulações determinaram os tempos necessários de aplicação de diferentes valores de corrente para obtenção dos diâmetros e penetração das lentilhas de solda recomendados em cada situação. Os resultados mostraram também que com o uso de maiores correntes menos energia é consumida na formação da lentilha de solda. Resumo em inglês The growth of the spot welding nugget in AISI 304 stainless steel sheets was analyzed by numerical simulation with the finite element method, being used for this purpose the commercial code ANSYS. The mathematical model considers: coupling between the electric and thermal fields in transient regimen; temperature dependent thermal and electrical properties of AISI 304 steel; convection thermal boundary condition. The analyzed three-dimensional geometry, axisymmetric, allow (mais) ed the simplification to a two-dimensional geometry. The results of the model were compared with experimental results presented in the literature. Sheets thickness of 1, 2 and 3 mm, and different diameters of electrodes faces were considered. The results allowed determining the necessary current application times for attainment the recommended diameter and penetration of the nugget in each situation. The results also showed that with the use of larger currents the nugget formation consumes less energy.

Scientific Electronic Library Online (Portuguese)

6

Estudo comparativo de métodos para estimativa do carregamento e rendimento de motores elétricos para auditoria energética/ Comparative study for estimation of load and performance of electric motors for energy audit

Campana, Saulo; Oliveira Filho, Delly; Soares, Antônio Alves; Oliveira, Rubens Alves de
2000-01-01

Resumo em português Este artigo investiga a precisão de três métodos indiretos para a determinação do índice de carregamento e rendimento de motores elétricos. Determinou-se o erro da estimativa do índice de carregamento e rendimento de motores elétricos pela média aritmética e geométrica das correntes e pela média aritmética dos fatores de potência. Mostrou-se, também, a importância da determinação do decréscimo do rendimento de motores elétricos, decorrente da variaç� (mais) �o de tensão da rede elétrica. Verificou-se que a estimativa do índice de carregamento e do rendimento dos motores elétricos por meio da medição do fator de potência médio aritmético apresentou resultados com maiores erros percentuais, 24,5% e 2%, respectivamente; já estas estimativas apresentaram, pelos métodos da corrente média aritmética e média geométrica, resultados semelhantes entre si e com erros percentuais significativamente inferiores aos resultados anteriores, ou seja, 6,2% e 1%, respectivamente. Resumo em inglês This article investigates the precision of methods for the load and efficiency estimate of electric motors. The error was determined by the estimate of load and efficiency of electric motors using the arithmetic and geometric average of the currents and the arithmetic average of the power factor in each phase. The importance was shown of the determination of the decrease in the electric motors' performance due to the variation of feeder tension, when the motors' load and (mais) performance evaluation in the load condition is performed. It was verified that the estimate of the electric motors' load and performance by the arithmetic average power factor, presented results with larger errors, that is, 24.5% and 2%, respectively. These estimates by the arithmetic and geometric average current method presented similar results to each other and with percentage errors significantly inferior to the previous results, that is, 6.2% and 1%, respectively.

Scientific Electronic Library Online (Portuguese)

7

Um controlador de corrente de carga para o conversor em matriz trifásico para trifásico e para o inversor de frequência sem capacitor do elo de corrente contínua/ A controller for the three-phase to three-phase matrix converter and for the voltage source three-phase inverter without DC-link capacitor

Oliveira Filho, M. E.; Sguarezi Filho, A. J.; Gazoli, J. R.; Ruppert Filho, E.
2010-10-01

Resumo em português Com o avanço da tecnologia dos dispositivos semicondutores de potência os inversores de frequência atuam de forma importante em toda indústria. O inversor de frequência convencional contém elementos armazenadores de energia no seu elo de corrente contínua. Estes elementos armazenadores de energia são capacitores eletrolíticos e possibilitam manter a tensão do elo de corrente contínua constante. Entretanto, quanto maior sua capacitância maior é a distorção d (mais) a corrente de entrada. Com a substituição do banco de capacitores eletrolíticos por um capacitor de filme, diminui-se a distorção nas correntes de entrada, porém distorções indesejadas aparecem na tensão do elo de corrente contínua e também nas correntes de saída. Estas distorções são compostas por componentes harmônicas de baixas frequências. O conversor em matriz trifásico-trifásico por sua vez, possibilita a transferência direta de energia da entrada (rede) diretamente para a saída (carga) sem a necessidade de elementos armazenadores de energia como acontece no inversor de frequência. Entretando o desbalanceamento das tensões da entrada afetam diretamente a forma de onda das tensões da saída. Dessa maneira, este trabalho propõe um método de controle de corrente do conversor em matriz e do inversor de frequência sem banco de capacitores do elo de corrente contínua com objetivo de compensar o desbalanceamento das tensões de saída do conversor em matriz e compensar também as componentes harmônicas de baixa frequência que aparecem nas correntes de saída do inversor de frequência. O método proposto utiliza um controlador do tipo PI e modulação por vetores espaciais para que a frequência de acionamento das chaves dos conversores seja constante. Resumo em inglês Voltage source three-phase inverter plays an important role in modern industry. The conventional voltage source inverter has a large electrolytic capacitor as energy store element in order to keep the DC-link voltage constant. However, a large electrolytic capacitor increases the input current distortion. Replacing the large electrolytic capacitor by a small film capacitor, the input current quality is improved but the DC-link voltage and the output currents are distorted (mais) by low order harmonic components. The three phase to three phase matrix converter performs electric energy direct transfer from the input to the output with sinusoidal input current although the distortion and the unbalance of the input voltages affects directly the output of the matrix converter. This paper proposes a load current control method to the matrix converter and also to the voltage source inverter in absence of the dc-link capacitor in order to compensate the distortion caused by low order harmonics components in the output currents. The proposed load current control scheme employs just one PI controller and since that the space vector modulation is used in this control, the switching frequency of the converter is kept constant. Theorical foundation, simulations results and experimental results are presented.

Scientific Electronic Library Online (Portuguese)

8

Origem do potencial elétrico espontâneo em rochas cristalinas fraturadas e sua utilização na locação de poços/ Self-potential anomaly generation in fractured crystalline rocks and its use to borehole location

Medeiros, W. E. de; Lima, O. A. L. de
1999-11-01

Resumo em português Medidas de potencial elétrico espontâneo (PE) foram realizadas no interior de poços e na superfície da terra, ao longo de seções transversais, em aqüíferos fissurais em rochas cristalinas do Estado da Bahia. Estas medidas revelam a presença de fortes anomalias de PE relacionadas à movimentação da água subterrânea. Com base em um modelo geométrico-hidráulico simplificado para um aqüífero freático, numa estrutura essencialmente bi-dimensional, e usando as (mais) equações básicas para os acoplamentos de fluxos de fluidos (ou de calor) e de concentração iônica, é mostrado que os efeitos eletrocinéticos desenvolvidos ao longo das paredes das fraturas podem produzir anomalias de PE comparáveis àquelas observadas no campo. Por outro lado, as estimativas obtidas para os acoplamentos associados aos efeitos eletroquímico e termo-elétrico são bem menores do que os estimados para o efeito eletrocinético, o que sugere que este último constitui a fonte dominante das anomalias de PE observadas em zonas fraturadas de rochas cristalinas. Com base neste resultado, foi feita a interpretação integrada de seções de resistividade aparente e perfis de PE de campo. Nesta interpretação, ficou evidenciado que o método de PE pode ser usado como uma técnica geofísica complementar ao método de eletro-resistividade na distinção de áreas com permeabilidade relativamente alta no interior de aqüíferos com porosidade fissural. Resumo em inglês Self-potential electric (SP) measurements made in wells and at the surface along traverses crossing aquifers in fractured crystalline rocks in the state of Bahia, Brazil, revealed the presence of strong anomalies related to groundwater movements. By considering a simple geometric-hydraulic model for a phreatic aquifer, in an essentially 2-D structure, and using basic equations for ionic concentration and fluid (or heat) coupled flows, it was found that electrokinetic effe (mais) cts developed along fracture walls can produce anomalies of amplitude comparable to those observed in the field. Estimates obtained for other coupled processes, such as the electrochemical and the thermo-electric effects, suggest that the electrokinetic effect is the most important component for setting up SP currents in fractured zones of crystalline rocks. Based on this result, a joint interpretation of pseudoresistivity sections and SP profiles was performed and the results show that the SP method can be used as a complementary geophysical technique to the resistivity method, allowing to distinguish areas of relative high permeability within fractured rocks.

Scientific Electronic Library Online (Portuguese)