Sample records for FORMA DE ONDAS (waveforms)
from WorldWideScience.org

Sample records 1 - 20 shown. Select sample records:



1

EFECTO DE LAS FORMAS DE ONDAS DE CORRIENTE PULSANTE EN LA ELECTRODEPOSITACIÓN DE NANOCRISTALES/ EFFECT OF PULSE CURRENT WAVEFORMS IN NANOCRYSTALLYNE ELECTRODEPOSITION

MOLINA, JAROL; HOYOS, BIBIAN
2009-06-01

Resumen en español Se desarrolló un modelo matemático para establecer el efecto que tiene la forma de las ondas de corriente pulsante en el tamaño y dureza de nanocristales electrodepositados. El modelo relaciona de forma directa las variables típicas de las ondas (frecuencia, ciclo de trabajo y corriente pico) con la dureza de los depósitos generados mediante corriente continua y con cuatro tipos de ondas de corriente pulsante: rectangular, rampa ascendente, rampa descendente y triang (mas) ular. Se evaluaron los resultados del modelo para ciclos de trabajo de 20 y 80%, con frecuencias de 50 y 150 Hz y corrientes pico de 4 y 8 kA/m². El modelo predice que pequeños aumentos en el sobrepotencial de concentración incrementan significativamente la velocidad de nucleación, disminuyen el crecimiento de los nanocristales y generan un aumento en la dureza. El aumento del ciclo de trabajo y la frecuencia de las ondas produce un comportamiento cada vez más cercano al producido por la corriente continua, con una disminución en la dureza de los nanocristales. Cualquier modificación en las variables de las ondas, que tenga como consecuencia el incremento de la corriente pico, produce valores de dureza más altos. Resumen en inglés A mathematical model has been developed for describing the effect of pulse current wave forms on size and hardness of electroplated nanocrystals. The model relates in a direct form the typical wave variables (frequency, duty cycle and peak current) with harness of generated deposits by means of direct current and by four pulse current wave forms: rectangular, ramp up, ramp down and triangular. The results of the model were evaluated for duty cycles of 20 and 80%, with fre (mas) quencies of 50 and 150 Hz and peak currents of 4 and 8 kA/m².The model predicts that small increases in the concentration overpotential drives to increase the nucleation rate significantly, diminishing the growth of the nanocrystals and generating a hardness increase. The increase of the duty cycle and the wave’s frequency produces a behavior increasingly close to that produced by direct current, with a diminution in the nanocrystals hardness. Any modification in the waveform variables that increases the peak current produces higher hardness values.

Scientific Electronic Library Online (Spanish)

2

RECTIFICADORES CA/CC TIRISTORIZADOS CON FORMAS DE ONDA DE ALTA CALIDAD/ THYRISTOR-BASED AC/DC RECTIFIERS WITH HIGH-QUALITY WAVEFORMS

Villablanca, Miguel; Cádiz, Carlos; Tapia, Jorge
2010-04-01

Resumen en español En este artículo un método y un aparato son aplicados a distintas configuraciones de rectificadores ca/cc tiristorizados para reducir la distorsión de las corrientes en el lado de C.A. La carga puede ser inductiva o capacitiva. La tecnología consiste en darle una adecuada forma de onda a la corriente en el lado de C.C. a través de dos interruptores de conmutación forzada. Esta forma de onda lograda en la corriente en el lado de C.C. se refleja en la forma de onda de (mas) las corrientes en el lado de C.A., las cuales se transforman en perfectas ondas senoidales. El circuito de control es simple y es también capaz de manejar variaciones rápidas de corriente de carga y fallas en los interruptores de conmutación forzada. La conducción simultánea de los tiristores del puente rectificador es eliminada completamente. La validación experimental de la tecnología es mostrada a través de un prototipo de laboratorio de 400 V, 50 Hz y 30 KVA Resumen en inglés In this paper both a method and apparatus are applied to different configurations of thyristor-based ac/dc rectifiers to reduce the distortion of currents flowing from the ac supply. The load may be either inductive or capacitive. The technology involves an accurate shaping of the dc current by using two self-commutated switches. This dc-current shaping is reflected back into the shaping of the ac input currents, which become pure sine waves. The control circuit is simple (mas) , and also able to deal with both rapid load variations and failures in the self-commutated switches. Furthermore, the overlap conduction of bridge thyristors is eliminated completely. Experimental verification is provided from a 400-V 50-Hz 30-kVA laboratory prototype

Scientific Electronic Library Online (Spanish)

3

Aplicación del método de la impedancia crítica para determinar la fuente armónica dominante en circuitos de media tensión/ Using the critical impedance method for determining the dominant harmonic source in medium voltage circuits

García M., Pável Julián; Rodríguez E., Lucien A.; Rojas, Herbert E.; Ríos, Carlos Alberto
2007-04-01

Resumen en español La automatización en procesos industriales ha dado como resultado la distorsión en las formas de onda de tensiones y corrientes ocasionando contaminación armónica en las redes de distribución. Este artículo presenta la aplicación de una metodología práctica para determinar la fuente armónica dominante en el punto de acople común (PCC) entre el operador de red (OR) y el cliente. La metodología parte del método de la impedancia crítica (CI) y requiere del moni (mas) toreo de las señales de tensión, corriente y ángulos de fase para cada componente armónico y los valores de impedancia de Thevenin del OR y del cliente vistos en el PCC. El método requiere para su aplicación de información aproximada de las impedancias del cliente y el OR y de un análisis matemático sencillo y estructurado basado en el estudio de las mediciones, que lo proyectan como una herramienta simple, coherente y práctica para solucionar el problema de la detección de la fuente armónica dominante en sistemas de distribución. Resumen en inglés Automating industrial processes has led to the distortion of current and voltage waveforms, causing harmonic contamination in distribution networks. This paper shows the application of a practical methodology which determines the dominant harmonic source at the point of common coupling (PCC) between the network operator (NO) and the client. This is known as the critical impedance (CI) method, requiring monitoring voltage, current and phase angle signals for each existing (mas) harmonic component and NO and client Thevenin impedance values seen in PCC. The method needs approximate impedance information to operate and a simple and structured mathematical analysis based on studying the measurements projecting a useful, reliable and practical solution for detecting the dominant harmonic source in distribution systems.

Scientific Electronic Library Online (Spanish)

4

Clasificación de señales electrocardiográficas contaminadas con ruido mediante representaciones tiempofrecuencia/ Electrocardiographic signal classification using time-frequency representations

Mendoza Reyes, Miguel A; Lorenzo Ginori, Juan V; Taboada Crispí, Alberto
2005-09-01

Resumen en español El análisis de señales electrocardiográficas (ECG) constituye un elemento importante en la realización de diferentes tareas de diagnóstico automatizado, mediante algoritmos de computación. Un objetivo importante dentro de este análisis es la clasificación de formas de onda, para lo cual han sido utilizados diferentes algoritmos de procesamiento de la señal ECG en los dominios del tiempo y de la frecuencia. La naturaleza no estacionaria de la señal ECG ha motivad (mas) o también la aplicación de técnicas tales como las Representaciones Tiempo-Frecuencia (RTF). El presente trabajo tiene como objetivos comparar el comportamiento de diferentes RTF en la clasificación de complejos QRS electrocardiográficos en presencia de ruido, e introducir un método de clasificación basado en el empleo de valores complejos para una RTF específica, la Transformada de Fourier Local. Se analizaron comparativamente los resultados de la aplicación del nuevo método con respecto a otro anterior introducido por los autores, también basado en RTF. Se determinó la efectividad del método evaluando el empleo de diferentes medidas de distancia entre los latidos contaminados con ruido y patrones de referencia utilizados para la clasificación. Se logró un desempeño superior durante la clasificación, para los tipos de ruido considerados, al emplear descriptores complejos en el dominio tiempo-frecuencia. Resumen en inglés The analysis of electrocardiographic (ECG) signals constitutes an important element in the completion of different tasks for automated diagnosis, by means of computational algorithms. Classification of waveforms is an important objective within this analysis, for which various ECG processing algorithms in the time and frequency domains have been used. The non-stationary nature of the ECG signal has motivated also the application of techniques such as the time-frequency re (mas) presentations (TFR). The objectives of this work are to compare, different alternatives for the application of TFR to the classification of noisy QRS, and to introduce a classification method based in the use of complex values for a specific TFR, the Short Time Fourier Transform. The results of the application of this method are analyzed in comparison to a previous method introduced by the authors, also based in the use of TFR. The effectiveness of this method to classify noisy beats was determined by evaluating the use of various distance measures between beats contaminated with noise and reference patterns used for classification. A better performance was obtained during classification, for the noise types considered, when complex descriptors in the time-frequency domain were used.

Scientific Electronic Library Online (Spanish)

5

Modelo de Transformador de Distribución Trifásico para Estudios de Máximos de Tensión (Peaks) Ocasionados por Descargas Atmosféricas/ Model of a Three-Phase Transformer for Studies of Voltage Surges (Peaks) due to Lighting Discharges

Kanashiro, A.G; Piantini, A; Burani, G.F
2004-01-01

Resumen en español Este trabajo se presenta una metodología para modelar transformadores de distribución trifásico para el estudio de los máximos (peaks) de tensión transferidos al secundario, en el caso de descargas atmosféricas directas o indirectas. La validación del modelo fue realizada a través de comparaciones entre simulaciones computacionales y resultados de ensayos obtenidos en el laboratorio. Los resultados mostraron que las tensiones transferidas presentadas por el modelo (mas) y por el transformador son mucho más próximas cuando se consideran los impulsos de tensión con formas de onda normalizada (1.2/40m s) y típicas de tensiones inducidas. El modelo es simple y representa razonablemente bien el transformador, permitiendo el análisis de las tensiones transferidas en las redes secundarias Resumen en inglés This paper presents a methodology for modeling three-phase distribution transformers for the analysis of the voltage surges transferred to the secondary networks when direct or indirect lightning discharges occur. The validation of the model was reached through comparisons between computer simulations and results of tests performed in the laboratory. The results showed that the voltages transferred presented by the model and by the transformer are quite similar when the v (mas) oltage impulses with both standard (1.2/50m s) and typical waveforms of induced voltages are considered. The model is simple and represents the transformer reasonably well, permitting the analysis of the voltages transferred in the secondary networks

Scientific Electronic Library Online (Spanish)

6

Usando el PSPICE orientado al analisis de los circuitos del controlador booster instalado en CVG Venalum/ USING THE PSPICE ORIENTED TO CIRCUITS ANALYSIS OF THE BOOSTER CONTROLLER INSTALLED IN CVG VENALUM

Fernández, Herman; Franco, Zulay Egilda
2009-06-01

Resumen en español El artículo muestra la utilidad del simulador de circuitos Pspice para comprender la operación del controlador de la Celda Booster instalado en CVG Venalum. El proceso de reducción de aluminio requiere de una fuente de corriente DC de gran potencia. El equipo de la celda Booster es capaz de alimentar la celda de reducción usando un rectificador de tiristores. El sistema tiene incorporado varias etapas de circuitos analógicos y digitales: las unidades de seguimiento, (mas) un integrador de voltaje, un regulador de corriente, un módulo de disparo, un atenuador de voltaje, un acondicionador de corriente y otros circuitos. Actualmente, la información técnica no es suficiente para comprender los circuitos en estado transitorio. Los ejemplos suministrados de Pspice representan un laboratorio virtual del sistema. Probando las simulaciones, observando las formas de ondas del voltaje, y determinando los componentes de estas señales, el equipo de técnicos tiene una mejor apreciación de los circuitos de la Celda Booster. Cuando es posible, los resultados de las simulaciones son comparados con las ecuaciones desarrolladas. Los resultados de las simulaciones pueden ser usados como soporte técnico durante las operaciones de mantenimiento. Resumen en inglés This paper shows the usefulness of the Pspice circuit simulator to understand the operation of the Booster-Cell controller installed in CVG Venalum. The aluminum reduction process requires of a high power DC current source. The Booster-Cell equipment is able to feed the reduction cell using a thyristor-rectifier. This system has incorporated several stages of analog and digital circuits: the buffer units, a voltage integrator, a current regulator, the gating module, an at (mas) tenuator voltage, a conditioner current amplifier and others circuits. Actually, the technical information not is enough to understand the transient-state response of these circuits. The considered Pspice examples represent a virtual laboratory of the system. Performing the simulations, observing the voltage waveforms, and determining waveforms components, the technical staffs have a better appreciation of Booster-Cell circuits. Whenever is possible, the simulation results are compared with theoretical ones gives by equations developed. The simulation results can be used as technical support during maintenance operations.

Scientific Electronic Library Online (Spanish)

7

Estrategias para la localización relativa de la fuente de huecos de tensión en sistemas de distribución de energía eléctrica/ Strategies for Voltage Sag Source Relative Location in Power Distribution Networks

Barrera Núñez, Víctor Augusto; Berjaga Moliner, Xavier; Ordóñez Plata, Gabriel; Meléndez Frigola, Joaquim
2009-12-01

Resumen en español En este artículo se presentan y comparan dos estrategias para estimar el origen (aguas arriba o aguas abajo) de huecos de tensión registrados en subestaciones de distribución. La primera estrategia se basa en la aplicación de una regla booleana que conjuga impedancias obtenidas antes y durante la perturbación. La segunda estrategia utiliza la forma de onda completa de las tensiones y corrientes trifásicas registradas durante el evento. Las dos estrategias fueron verificadas con huecos de tensión registrados en subestaciones de distribución. Resumen en inglés In this paper two strategies to estimate the origin (upstream or downstream) of voltage sags gathered in distribution substation are presented and compared. The first strategy is based on boolean rule that contains impedances obtained before and during the perturbation. The second strategy uses the three-phase voltage and current complete waveforms gathered during the event. Both strategies were verified with voltage sag events gathered in distribution substations.

Scientific Electronic Library Online (Spanish)

8

Nuevas evidencias de la actividad sísmica del terreno Cuyania en la región de subducción de placa horizontal de Argentina/ New evidence for the seismic activity of the Cuyania terrane in the flat slab subduction region of Argentina

Alvarado, Patricia; Sánchez, Gerardo; Saez, Mauro; Castro de Machuca, Brígida
2010-08-01

Resumen en español El terreno Cuyania situado en la zona andina de trasarco entre 29°Sy 34°S se compone de un sistema de corrimientos y retrocorrimientos del cinturón plegado de Precordillera y más hacia el este por bloques de basamento cristalino de las Sierras Pampeanas Occidentales. A 31°S aproximadamente, la zona se caracteriza por una elevada actividad sísmica que ocurre a niveles de corteza continental (< 35 km de profundidad) y de profundidad intermedia (~100 km). Esta últi (mas) ma define la zona de Wadati-Benioff indicando una geometría de la placa de Nazca subducida en posición horizontal bajo Sudamérica en buena correlación con la localización de la dorsal de Juan Fernández, la cual parece continuar en subducción en dirección hacia el noreste bajo el continente. En este trabajo se presentan los resultados de la inversión del tensor momento sísmico para cinco sismos corticales que ocurrieron en 2008 y 2009 con epicentros en el terreno Cuyania y sus límites. La información obtenida corresponde a estimaciones refinadas de localización sísmica, momento sísmico (M0), magnitud momento (Mw), profundidad focal y parámetros de fallamiento para los mecanismos focales de estos sismos. La caracterización de estas fuentes sísmicas ha sido obtenida a partir del modelizado de formas de ondas sísmicas de bancha ancha completas para las tres componentes registradas por la red local "Sierras pampeanas Experiment using a Multicomponent BRoadband Array" (SIEMBRA). Los sismos estudiados muestran magnitudes Mw entre 3.5 y 5.3, mecanismos focales de fallamiento inverso y profundidades focales entre 5 y 30 km, lo cual es consistente con otras soluciones obtenidas anteriormente para la misma zona con técnicas similares. Esta deformación sísmica está de acuerdo con el régimen de esfuerzo compresivo actual observado dentro de la corteza del terreno Cuyania situada por encima de la placa de Nazca subducida horizontalmente. Las propiedades de la corteza del terreno Cuyania (espesor de ~50 km; alta velocidad de ondas P, alta relación entre las velocidades de ondas P y S y elevada densidad en sus niveles más profundos), del manto superior situado entre la zona de Wadati-Benioff y el Moho y un mayor acoplamiento entre las litósferas continental y oceánica favorecerían la transferencia de esfuerzos desde la zona de contacto de placas a más de 500 km hacia el este, causando una mayor generación de sismos corticales en el terreno Cuyania que en los terrenos adyacentes. Resumen en inglés The Cuyania terrane in the Andean backarc region between 29°S and 34°S consists of the thin-skinned Precordillera fold and thrust belt and of the Western Sierras Pampeanas thick-skinned basement cored uplifts. At about 31°S, the region is highly seismically active at crustal levels (< 35 km depth) and intermediate depths (~100 km). This deeper seismic activity delimitates the Wadati-Benioff zone showing a geometry of the subducted Nazca plate nearly horizontal benea (mas) th South America in good correlation with the location of the Juan Fernandez ridge, which seems to continue its subduction to the northeast beneath the continental plate. In this paper we present the results of the seismic moment tensor inversion forfive crustal earthquakes that occurred in 2008 and 2009 with epicenters in the Cuyania terrane and its boundaries. We provide refined information of the seismic location, seismic moment (M0), moment magnitude (Mw), focal depth and fault parameters of the focal mechanisms for these earthquakes. The seismic source characterization was obtained after modeling the three component full seismic broadband waveforms recorded by the Sierras Pampeanas Experiment using a Multicomponent BRoadband Array (SIEMBRA) local network. The earthquakes show magnitudes Mw between 3.5 and 5.3, dip-slip focal mechanisms and focal depths between 5 and 30 km, which are consistent with previous constraints in the same area using similar inversion techniques. The earthquake deformation is expected according to the compressional stress regime estimated in the crust of the Cuyania terrane over the flat slab subduction segment. The properties of the Cuyania terrane (thick crust of about 50 km thickness; high P-wave velocity; high P- to S-wave velocity ratio and high density in its deeper levels), of the upper mantle between the Wadati-Benioff zone and the Moho, and a stronger coupling between the oceanic and continental lithospheres may favor the transference of stresses from the coupled zone in the west to more extended inland areas located 500 km to the east causing a higher generation of crustal earthquakes in the Cuyania terrane in comparison to adjacent crustal terranes.

Scientific Electronic Library Online (Spanish)

9

Electrodeposición de Níquel Duro con Ondas de Corriente Pulsante Triangulares/ Electroplating of Hard Nickel With Triangular Pulse Current Waveforms

Hoyos, Bibian A; Martínez, Luisa F; Salazar, Álvaro F
2007-01-01

Resumen en español Se estudia el efecto de la frecuencia y la densidad de corriente sobre la dureza en electrodepósitos de níquel obtenidos mediante corrientes pulsantes triangulares y rectangulares y su comparación con los obtenidos empleando corriente directa. Las mediciones de dureza se realizaron según la norma ASTM E384. La descripción de la morfología de los depósitos se realizó mediante un microscopio de barrido electrónico (SEM) según las normas ASTM E112, E3 y E93. Los re (mas) sultados experimentales muestran que a 4 A/dm² la dureza de los depósitos está influida por la forma de onda, produciéndose durezas en el orden rampa descendente > rectangular > rampa ascendente. Para las condiciones exploradas, la mayor dureza se obtiene con onda rectangular a 20 A/dm² y 60 Hz. Para ésta onda de corriente, la dureza disminuye al aumentar el ciclo de trabajo. La dureza tiene un aumento de hasta un 300% cuando se emplea corriente pulsante frente a los valores alcanzados con corriente directa Resumen en inglés In this paper it is studied the frequency and current density effect on hardness of nickel electroplating obtained by means of triangular and rectangular pulse current and their comparison with those obtained using direct current. Hardness measurements were done following the ASTM E384 standards. Morphologic qualitative description of deposits was done using a Scanning Electronic Microcopy (SEM) according with the ASTM E112, E3 and E93 standards. The experimental results (mas) showed that at 4 A/dm² the hardness of deposits is affected by the current waveform, producing hardness in the order: ramp-down > rectangular > ramp-up. For the experimental conditions explored here, the highest value of hardness was obtained at t 20 A/dm2 and 60 Hz. For this current waveform the hardness value diminishes when the duty cycle increases. The hardness increases up to 300% when using pulse current instead on direct current

Scientific Electronic Library Online (Spanish)

10

Waveform Shaping of Sonar Transducers for Improving the Vertical Resolution in Sub-bottom Sediments Profiling

Cobo, Pedro; Ranz Guerra, Carlos; Fernández, Alejandro; Anthony, David K.; Siguero, Manuel
2005-06-01

Digital.CSIC (Spain)

11

Utilización de redes ANFIS y señales de corriente para localización de la zona de falla en sistemas de distribución de energía eléctrica/ Using ANFIS networks and current signals for locating faults in power distribution systems

Mora Flórez, Juan José; Pérez Hernández, Lucas Paúl; Pérez Londoño, Sandra Milena
2006-12-01

Resumen en español El problema de la localización de fallas en sistemas de distribución de energía eléctrica es muy importante debido a los requerimientos de continuidad del servicio, impuestos por las normativas de calidad propias del mercado eléctrico actual. En este artículo se presenta una alternativa de localización de fallas que sólo utiliza las señales de corriente medidas en la subestación de distribución, el conocimiento de la calibración del sistema de protecciones y r (mas) edes neurodifusas ANFIS. A partir de las pruebas realizadas en un sistema de distribución prototipo, se obtienen buenos resultados para la localización de la zona donde se originó la falla. Estos resultados muestran la variación de la precisión del localizador ante el uso de diferentes características o descriptores de la señales de corriente. En el mejor de los casos, el error encontrado es inferior al 1%; pero también se presentan dos alternativas adicionales para las cuales el error es inferior al 4%, lo cual valida plenamente la propuesta aquí presentada. Resumen en inglés Fault location in power distribution systems is very important because of power service continuity requirements, mainly imposed by current electricity market quality standards. A fault location approach is adopted in this paper using current waveforms as measured at electricity substations, knowledge of protection-device settings and ANFIS networks. Good results were obtained from tests carried out in a prototype power distribution system to locate where faults were occur (mas) ring. These results revealed variation in fault-locator precision due to using different current signal characteristics or descriptors. An error lower than 1% was obtained in the best case. Two more alternatives are also presented where errors were lower than 4%; such results validate the approach presented here.

Scientific Electronic Library Online (Spanish)

14

TDR application for automated water level measurement from Mariotte reservoirs in tension disc infiltrometers

Moret Fernández, David; López Sánchez, María Victoria; Arrúe Ugarte, José Luis
2004-09-01

Digital.CSIC (Spain)

16

Sistema de excitación por pulsos para la caracterización de resonadores para atomización

Lozano Fantoba, Manuel; Jordà, Xavier; Chico, E.; Lozano Fantoba, Antonio; Amaveda, H.; Barreras Toledo, Félix
2002-01-01

Digital.CSIC (Spain)

17

Simulating Echo Responses from Arbitrary-Geometry Targets Using Mode Conversion Approach

Buiochi, Flávio; Martínez Graullera, Óscar; Gómez-Ullate Alvear, Luis; Montero de Espinosa Freijo, Francisco
2008-01-01

Digital.CSIC (Spain)

21

Probing and Feeding Behavior of Two Distinct Biotypes of Bemisia tabaci (Homoptera: Aleyrodidae) on Tomato Plant

Jiang, Y-X.; Lei, H.; Collar, J. L.; Martín, B.; Muñiz, M.; Fereres, Alberto
1999-01-01

Digital.CSIC (Spain)

23

PSPICE simulation of transient responses of transducers and spike generators included in E/R ultrasonic systems

Ruiz Toledo, Abelardo; Ramos, Antonio; San Emeterio, José Luis; Sanz Sánchez, Pedro Tomás
2002-09-01

Digital.CSIC (Spain)

27

Nonlinear Dynamics of Semiconductor Lasers with Mutual Optoelectronic Coupling

Tang, Shuo; Vicente, Raúl; Chiang, Margaret; Mirasso, Claudio R.; Liu, Jia-Ming
2004-01-10

Digital.CSIC (Spain)

28

Monochromatic blue light entrains diel activity cycles in the Norway lobster, Nephrops norvegicus (L.) as measured by automated video-image analysis

Aguzzi, Jacopo; Costa, Corrado; Menesatti, Paolo; García, José A.; Chiesa, Juan José; Sardà, Francisco
2009-12-30

Digital.CSIC (Spain)

29

Modelo Matemático de la Nucleación Electroquímica con Ondas de Corriente Pulsante/ Mathematical Model for the Electrochemical Nucleation with Pulse Current Waveforms

Molina, Jarol E; Hoyos, Bibian A
2007-01-01

Resumen en español Se presenta un modelo matemático para describir el sobrepotencial de concentración, la velocidad de nucleación y el tamaño de núcleos formados sobre sustratos metálicos, cuando se emplean cuatro tipos de ondas de corriente pulsante: rectangular, rampa ascendente, rampa descendente y triangular. Para el desarrollo del modelo, se considera que la etapa que controla el proceso es la difusión de especies en la capa limite. El modelo predice que, cuando se emplean ondas (mas) con igual corriente promedio e igual tiempo de aplicación, la rampa descendente produce tiempos de transición más cortos, con mayor aumento en el sobrepotencial de concentración, lo que lleva a mayores velocidades de nucleación con tamaños de núcleos más pequeños. Para el caso de ondas con igual corriente pico y promedio, las ondas rectangular y descendente presentan prácticamente el mismo tiempo de transición, con velocidades de nucleación y tamaño de los depósitos equivalentes. El modelo desarrollado, constituye una herramienta ágil y flexible para la determinación del tamaño y la velocidad de formación de núcleos de electrodepositos y, puede ser extendida para estudiar otro tipo de ondas de corriente Resumen en inglés A mathematical model has been established for the description of concentration overpotential, nucleation rate and nucleus size formed on metallic substrates when four types of pulse current waveforms are used: rectangular, ramp-down, ramp-up and triangular. The mathematical model was developed considering that the species diffusion in the limit layer is the rate determining step of the process. The model predicts that when using wave current with the same current average (mas) and the same time of application, the ramp-down current produces the shortest transition time, with the highest rise of overpotential concentration, this drives to high nucleation rates with small nucleus size. For the case of current wave forms with the same pick and average current, the rectangular and ramp-down waves show practically the same transition time, with equivalent nucleation rate and deposit size

Scientific Electronic Library Online (Spanish)

30

Message Encryption by Phase Modulation of a Chaotic Optical Carrier

Annovazzi-Lodi, Valerio; Benedetti, Mauro; Merlo, Sabina; Pérez, Toni; Colet, Pere; Mirasso, Claudio R.
2007-01-10

Digital.CSIC (Spain)

31

Measurement of soil bulk electrical conductivity in saline soils and solutions using TDR probes partially coated with high-dielectric material

Moret Fernández, David; Lera, F.; Arrúe Ugarte, José Luis; López Sánchez, María Victoria
2009-07-01

Digital.CSIC (Spain)

33

In situ absorption measurement of antinoise devices using pre-determined pulse waveforms

Cobo, Pedro; Fernández, Alejandro; Palacios, R.; Colina, Carlos de la; Siguero, Manuel

8 pages, 6 figures.-- Comunicación presentada en: XXXV Congreso Español de Acústica – TecniAcústica 2004, IV Congreso Iberoamericano de Acústica, IV Congreso Ibérico de Acústica y EAA Symposium "Environmental and Architectural Acoustics" (Guimaraes, 14-17 Sep 2004). | Noise barriers can be character...

DRIVER (Spanish)

34

In situ absorption measurement of antinoise devices using pre-determined pulse waveforms

Cobo, Pedro; Fernández, Alejandro; Palacios, R.; Colina, Carlos de la; Siguero, Manuel
2004-09-01

Digital.CSIC (Spain)

36

Experimental observation of nonlinear self-focusing in the cavitation field

Campos-Pozuelo, Cleofé; Granger, C.; Vanhille, Christian; Dubus, Bertrand
2007-12-01

Digital.CSIC (Spain)

37

Evidences on the transient disruption of spallanzanii (Polychaeta, Sabellidae) fan activity rhythm in laboratory constant darkness

Costa, Corrado; Aguzzi, Jacopo; Chiesa, Juan José; Magnifico, Giuseppe; Cascione, Davide; Rimatori, Valentina; Caprioli, R.
2008-12-01

Digital.CSIC (Spain)

38

Effect of Clock Jitter Error on the Performance Degradation of Multi-bit Continuous-Time ΣΔ Modulators With NRZ DAC

Tortosa, Ramón; Rosa Utrera, José Manuel de la; Rodríguez Vázquez, Angel; Fernández, Francisco V.
2005-11-01

Digital.CSIC (Spain)

39

EFECTO DE ADITIVOS EN LA DUREZA DE LOS DEPOSITOS DE NÍQUEL UTILIZANDO CORRIENTE PULSANTE/ ADDITIVES EFFECT ON NICKEL COATINGS HARDNESS WITH PULSE CURRENT

ARANGO, LUIS; CARMONA, JUAN; VALLEJO, ELKIN; HOYOS, BIBIAN
2006-11-01

Resumen en español Este trabajo comprende el estudio experimental del efecto conjunto de la inclusión de aditivos (sacarina de sodio y cloruro de amonio), y la utilización de una onda de corriente rectangular, en la dureza de níquel electro-depositado sobre cobre usando baños Watts y Sulfamato. Se obtuvieron recubrimientos brillantes y con altas durezas con la utilización de sacarina de sodio. El uso de cloruro de amonio produjo depósitos opacos y no tuvo un efecto significativo sobre (mas) la dureza. Adicionalmente, son mostrados los cambios morfológicos en la superficie de los electro-depósitos con microscopía de barrido de electrones (SEM). Resumen en inglés An experimental research for evaluating the effect of additives inclusion (sodium saccharine and ammonium chloride) and rectangular current waveforms in nickel electroplating on copper substrate using Watts and Sulfamate baths was made. Bright coatings with high hardness were obtained using sodium saccharine; on the other hand, dull deposits and a hardness negligible effect, were found with ammonium chloride. Surface morphology changes were detected by means of Scanning Electron Microscopy (SEM).

Scientific Electronic Library Online (Spanish)

40

Determinación del perfil de humedad del suelo utilizando una sola sonda TDR: el método del nomograma

Moret Fernández, David; Arrúe Ugarte, José Luis; López Sánchez, María Victoria; Gracia Ballarín, Ricardo; Álvaro-Fuentes, Jorge; Salvador, María José
2007-01-01

Digital.CSIC (Spain)

44

Clock Jitter Error in Multi-bit Continuous-Time Sigma-Delta Modulators with Non-Return-to-Zero Feedback Waveform

Tortosa, Ramón; Rosa Utrera, José Manuel de la; Fernández, Francisco V.; Rodríguez Vázquez, Angel
2008-01-01

Digital.CSIC (Spain)

45

Circadian and Ultradian Rhythmicities in Very Premature Neonates Maintained in Incubators

Schimmel, Martin; Waterhouse, J.; Marques, M.D.; Weinert, D.
2002-02-01

Digital.CSIC (Spain)

47

Breaking a secure communication scheme based on the phase synchronization of chaotic systems

Álvarez Marañón, Gonzalo; Montoya Vitini, Fausto; Pastor, Gerardo; Romera, Miguel
2004-05-11

Digital.CSIC (Spain)

48

Análisis de los ruidos respiratorios y sibilancias en fiposis quística/ Breath sound analysis and wheezing in cystic fiposis

Sánchez D, Ignacio; Vizcaya A, Cecilia; García P, Daniela
2003-11-01

Resumen en español Las sibilancias son sonidos musicales que provienen de las vías aéreas obstruidas, que dependen del flujo aéreo, una presión crítica y una distorsión geométrica de la vía aérea. Nuestro objetivo fue caracterizar las sibilancias y el espectro de los ruidos respiratorios en pacientes con Fiposis Quística (FQ), con el propósito de conocer la repercusión acústica de la obstrucción ponquial en este grupo de pacientes. Se estudiaron 14 pacientes (8 niños), de eda (mas) d 14,3 ± 2 años (8 + D.S.), seis niños fueron portadores de la mutación deltaF508/deltaF508. La espirometría basal demostró CVF: 56 ± 15%, VEF1:44 ± 12%, FEF25-75: 40 ± 14% y SaO2: 93,4 + 2%. Los pacientes respiraron a través de un pneumotacómetro con flujos de 0,5 ± 0,05 l/s. Los ruidos respiratorios se grabaron utilizando sensores de contacto en el espacio supraesternal y en la pared torácica correspondiente al lóbulo inferior derecho. Las señales de sonidos se filtraron, amplificaron y se aplicó un análisis de Fourier a los sonidos dentro de la ventana de flujo previamente determinada. Desde el espectro de sonidos analizado, se obtuvo el cálculo de la intensidad con bajas frecuencias (P1= 100-200 Hz) y con altas frecuencias (P2= 400-2 000 Hz). Se midió las frecuencias bajo las cuales el 50% (F50) y 99% (SEF99) se ubicó el espectro de la intensidad entre 100-2 000 Hz. Luego de obtener un registro basal, los pacientes recibieron salbutamol inhalado (200 mg) y 15 minutos después se repitieron las mediciones. Solo en 6/14 pacientes se obtuvo la onda sinusoidal característica de las sibilancias, los otros pacientes presentaron ondas complejas. Hubo un aumento significativo en P1y una disminución en P2, durante la inspiración después de salbutamol (p Resumen en inglés Wheezes are musical sounds caused by obstructed airways and depend on airflow, a critical pressure and a geometrical airway distortion. Objective to characterize wheezing and the lung sound spectra in cystic fiposis (CF). Patient and Methods: 14 patients (8 boys), aged 14.± 2 years, 6 children had deltaF508/deltaF508 mutation. Subjects peathed through a pneumotachograph at flows of 0.5 ± 0.05 l/s. Respiratory sounds were recorded using contact sensors on the supra-stern (mas) al notch and on the thoracic region corresponding to the right lower lobe. Sound signals were low-pass filtered, amplified and Fourier analisis was applied to sounds within the target flow range. From averaged spectra, power at low (100-200 Hz = P1) and high frequencies (400-2 000Hz = P2) were calculated. We measured the frequencies below in which 50% (F50) and 99% (SEF99) of the spectral power between 100-2 000 Hz were contained. After baseline recording, patients received inhaled salbutamol (200 mcg) and 15 minutes later the measurements were repeated. Results:Baseline spirometry was FVC ± 15%, FEV(1)44 ± 12%, FEF25-75: 40 ± 14% and SaO(2)93.4 ± 2%. Only in 6/14 patients we obtained a sinusoidal waveform of a typical wheeze, the others had complex waveforms. There was a significant increase in P1and decrease in P2during inspiration after salbutamol (p

Scientific Electronic Library Online (Spanish)

49

Analysis of Clock Jitter Error in Multibit Continuous-Time ΣΔ modulators with NRZ Feedback Waveform

Tortosa, Ramón; Rosa Utrera, José Manuel de la; Rodríguez Vázquez, Angel; Fernández, Francisco V.
2005-05-01

Digital.CSIC (Spain)

50

An 0.5-μm CMOS analog random access memory chip for TeraOPSspeed multimedia video processing

Carmona, Ricardo; Espejo, Servando; Domínguez Castro, Rafael; Rodríguez Vázquez, Angel; Roska, Tamás; Kozek, Tibor; Chua, Leon O.
1998-09-07

Digital.CSIC (Spain)

51

Alteraciones frecuenciales de la excitación en casos prácticos de control de calidad por pulsos ultrasónicos

Ramos, Antonio; Sanz Sánchez, Pedro Tomás; San Emeterio, José Luis; Cegarra, Manuel
2000-10-01

Digital.CSIC (Spain)

52

A new absolute arrival time data set for Europe

Amaru, M.L.; Spakman, W.; Villaseñor, A.; Sandoval, S.; Kissling, E.
2008-02-01

Digital.CSIC (Spain)

53

A new TDR waveform analysis approach for soil moisture profiling using a single probe

Moret Fernández, David; Arrúe Ugarte, José Luis; López Sánchez, María Victoria; Gracia Ballarín, Ricardo
2006-04-01

Digital.CSIC (Spain)