Sample records for TRANSDUCTORES (transducers)
from WorldWideScience.org

Sample records 1 - 20 shown. Select sample records:



1

Transductores macrosónicos tipo placa vibrante escalonada Fundamentos, desarrollos, estado actual

Gallego Juárez, Juan Antonio; Rodríguez, Germán; Vázquez, F.; Gaete Garretón, Luis; Campos-Pozuelo, Cleofé; Riera, Enrique; Montoya Vitini, Fausto; San Emeterio, José Luis; Ramos, Antonio; Sanz Sánchez, Pedro Tomás; Lázaro, J. C.; Acosta Aparicio, Víctor Manuel; Gálvez, J. C.; Elvira, Luis; Nájera, G.; Blanco Blanco, Alfonso; Andrés Gallego, Eduardo; Navajas, M.
2000-12-01

Digital.CSIC (Spain)

3

Aplicación de transductores de estado-finito a los procesos de unificación de términos/ Application of transducers of state-finite to unification processes of term variants

Galvez, Carmen
2006-12-01

Resumen en español Se presenta una aplicación basada en técnicas de estado-finito a los procesos de unificación de términos en español. Los algoritmos de unificación, o conflación, de términos son procedimientos computacionales utilizados en algunos sistemas de Recuperación de Información (RI) para la reducción de variantes de términos, semánticamente equivalentes, a una forma normalizada. Los programas que realizan habitualmente este proceso se denominan: stemmers y lematizado (mas) res. El objetivo de este trabajo es evaluar el grado de deficiencias y errores de los lematizadores en el proceso de agrupación de los términos a su correspondiente radical. El método utilizado para la construcción del lematizador se ha basado en la implementación de una herramienta lingüística que permite construir diccionarios electrónicos representados internamente en Transductores de Estado-Finito. Los recursos léxicos desarrollados se han aplicado a un corpus de verificación para evaluar el funcionamiento de este tipo de analizadores léxicos. La métrica de evaluación utilizada ha sido una adaptación de las medidas de cobertura y precisión. Los resultados muestran que la principal limitación del proceso de unificación de variantes de término por medio de tecnología de estado-finito es el infra-análisis. Resumen en inglés An approach based on techniques of state-finite has applied to the processes of unification of terms in Spanish. The algorithms of conflation are computational procedures utilized in some Information Retrieval (RI) systems for the unification of term variants, semantically equivalent, to a normalized form. The programs that carry out habitually this process are called: stemmers and lematizadores. The objective of this work is to evaluate the deficiencies and errors of the (mas) lematizadores in the conflation of terms. The method utilized for the construction of the lematizador has been based on the implementation of a linguistic tool that permits to build electronic dictionaries represented internally in Finite-State Transducers (FST). The lexical resources developed have applied to a corpus of verification to evaluate the performance of these lexical parsers. The metric of evaluation utilized has been an adaptation of coverage and precision measures. The results show that the main limitation of unification processes of tem variants through technology of state-finite is the under-analysis.

Scientific Electronic Library Online (Spanish)

4

Desarrollo de Transductores Ultrasónicos de Potencia con Radiadores de Placa para Procesos Industriales en Líquidos

Bazán Sulzberger, Antonio; Gallego Juárez, Juan Antonio; Rodríguez Corral, Germán
2004-09-01

Digital.CSIC (Spain)

7

Comportamiento no lineal de piezocomposites en transductores resonantes de potencia

Albareda, A.; Casals, J. A.; Montero de Espinosa Freijo, Francisco; Kayombo, J. H.
1999-10-01

Digital.CSIC (Spain)

8

Estudio de vibraciones paramétricas y no lineales en transductores ultrasónicos de potencia

Chacón, David; Riera, Enrique

8 pages, 10 figures.-- Comunicación presentada en: XXXV Congreso Español de Acústica – TecniAcústica 2004, IV Congreso Iberoamericano de Acústica, IV Congreso Ibérico de Acústica y EAA Symposium "Environmental and Architectural Acoustics" (Guimaraes, 14-17 Sep 2004). | [EN] High-power ultrasonic dev...

DRIVER (Spanish)

11

Onoma: un conjugador de verbos y neologismos verbales Onoma: a conjugator tool for verbs and verb neologisms

Rello, Luz; Basterrechea, Eduardo

Este artículo presenta el funcionamiento de Onoma, un conjugador en línea que es capaz de conjugar y analizar tanto los verbos existentes como los verbos nuevos en español. El sistema, basado en diferentes módulos y en transductores de estados finitos, se ha evaluado con otros conjugadores en red, a...

DRIVER (Spanish)

12

UNA VISUALIZACIÓN DE UN SISTEMA DE INFERENCIA A TRAVÉS DE TREEBAG/ A VISUALIZATION OF INFERENCE SYSTEM THROUGH TREEBAG

Aguirre, Mauricio; Jeltsch, Eric; Rosales, Gerardo
2007-04-01

Resumen en español En este trabajo se desarrolla un algoritmo de inferencia gramatical, el cual posee como entrada un conjunto finito de árboles y como salida top-down tree generator (td generador), que consiste de una gramática de árbol regular y un conjunto finito de transductores. Se presenta también el sistema de software TreeBag (Tree Based Generador), herramienta útil para la generación y visualización de objetos de todo tipo: grafos, árboles, string, etc Resumen en inglés In this paper, a grammatical inference algorithm is developed with finite sets of sample trees as inputs and top-down tree generator (td generator) consisting of regular tree grammars and a finite sequence of transducers as outputs. A software system called TreeBag (Tree Based Generator) is presented, its aim being allowing the generation and visualization of objects of all kinds such as: graphs, trees, strings, etc

Scientific Electronic Library Online (Spanish)

13

Ultrasonic velocity and attenuation in carbon steel specimens

Buitrago, Brenda; Irausquín, Ignacio; Mendoza, Johnny
2004-04-01

Resumen en español La inspección y evaluación de materiales mediante el método no destructivo ultrasónico se ha convertido en una herramienta muy útil y sensible para determinar las propiedades acústicas de los mismos. En virtud de ello, este estudio ha tenido por objeto la medición de la velocidad ultrasónica longitudinal y la estimación de atenuación ultrasónica para tres muestras de acero al carbono. Esta caracterización ultrasónica se hizo mediante la técnica pulso-eco de (mas) contacto directo utilizando transductores de 0,375” (9,525 mm) de diámetro con frecuencias centrales de 1,5; 2,25; 5; 7,5 y 10 MHz, además de glicerina como medio acoplante. Los resultados mostraron una variación insignificante de la velocidad ultrasónica en el espectro de frecuencia de cada muestra y variaciones significativas de su atenuación. Así mismo se encontraron diferencias de velocidad y atenuación entre las muestras, proporcionales a su concentración de carbono. Resumen en inglés Materials testing and inspection by means of the ultrasonic nondestructive method, has become an useful and sensitive tool to determine its acoustic properties. By virtue of this, the purpose of the following study was to measure the longitudinal ultrasonic velocity and to estimate the ultrasonic attenuation for three carbon steel specimens. This ultrasonic characterization was done by means of the pulse-echo technique using transducers with a diameter of 0.375” (9. (mas) 525 mm) and center frequencies of 1.5, 2.25, 5, 7.5 and 10 MHz, besides glycerin as coupling. Results showed an insignificant change in the frequency spectrum of each specimen and significant changes of its attenuation. Likewise differences in velocity and attenuation were found between the specimens, proportionally to its carbon concentration.

Scientific Electronic Library Online (Spanish)

14

Actividad biológica de la prostaglandina F2 alfa y del metil carboprost en el fundus gástrico aislado de rata

Rojas Martínez, Roberto; Sánchez Sanciñenas, Marlene; Morón Rodríguez, Francisco
1997-08-01

Resumen en español Se comparó la potencia contráctil de una muestra del éster metílico de 15 metil prostaglandina F2 alfa (metil carboprost) (I), producida por la Industria Farmacéutica Cubana, con una muestra comercial de prostaglandina F2 alfa (II), de la firma Chinoin, mediante el ensayo de los "tres puntos". También se comparó la duración de la contracción inducida por dichas muestras utilizando un análisis de regresión lineal de la relajación observada en función del tiemp (mas) o, luego de suprimir el contacto entre la droga y el órgano efector. Se utilizó el fundus gástrico aislado de rata como órgano efector. La actividad contráctil se registró mediante transductores fuerza-desplazamiento. La muestra I presentó una potencia relativa de 164,0 % con respecto a la II, con límites de confianza de 111,2 y 247,8 % (p=0,95; N=7), y mostró un efecto más prolongado en relación con la II. En las tiras contraídas por la muestra I debió transcurrir 6 min y 46 s, luego del lavado, para que la contracción se redujera a la mitad de la respuesta máxima observada (N=7), en tanto que en las tiras contraídas por la II fue de 1 min y 48 s (N= 8). Resumen en inglés The contractil potency of a sample of methylic ester of 15 methyl prostaglandin F2 alpha (methyl carboprost) (I) produced by the Cuban Pharmaceutical Industry, was compared to a commercial sample of prostaglandin F2 alpha (II) from a Chinoin firm through the "three point" assay. The duration of the contraction induced by such samples was also compared using the analysis of linear regression of the relaxation observed in function of time after the supression of contact bet (mas) ween the drug and the effector organ. The gastric fundus isolated from a rat was used as the effector organ. The contractil activity was recorded by strength-displacement transducers. Sample I showed a relative potency of 164.0 % with respect to sample II, with confidence limits of 111.2 and 247.8 % (P = 0.95; N=7) and it also showed a more prolonged effect in relation to sample II. In the strips contracted by sample I the elapsed should have been 6 min and 46 sec after washing, for the contraction to be reduced to a half of the minimun response observed (N=7), while in strips contracted by sample II the time elapsed was 1 min and 48 sec (N=8).

Scientific Electronic Library Online (Spanish)

15

Diagnóstico ecocardiográfico de los tumores primarios del corazón en el feto/ Echocardiographic diagnosis of fetal primary heart tumors

Savío Benavides, Andrés; Oliva Rodríguez, José; García Morejón, Carlos; García Guevara, Carlos; Arencibia Faire, Jacqueline; Ponce Bittar, Jorge
2009-12-01

Resumen en español INTRODUCCIÓN. Se describen las características ecocardiográficas de los tumores cardíacos primarios en el feto y la evolución y complicaciones de éstos, con el propósito de analizar su comportamiento en dos períodos diferentes a lo largo de 20 años. MÉTODOS. El estudio se desarrolló en dos etapas. En la primera se estudiaron 1,884 embarazadas entre las 18 y 22 semanas de gestación, que acudieron a la consulta por distintos factores de riesgo obstétrico. La t� (mas) �cnica utilizada fue la misma empleada internacionalmente, con equipos Combison 320-5 y Aloka 860 con transductores electrónicos de 3,5 y 5 MHz, y Doppler codificado en color, para el estudio de los flujos intracavitarios y los gradientes de presión. RESULTADOS. Se identificaron 6 tumores cardíacos, lo que representó el 0,3 % de los casos examinados. Cinco correspondieron a rabdomiomas, y uno, a un mixoma de la aurícula derecha. La mayoría obstruía los tractos de entrada o salida. Se observó arritmia en un caso. La sensibilidad y especificidad fueron del 100 % y 99,8 %, respectivamente. CONCLUSIONES. Se demuestra la poca frecuencia de los tumores cardíacos en el feto y la importancia de la ecocardiografía por su alta sensibilidad y especificidad. Resumen en inglés INTRODUCTION: Echocardiographic features of fetal primary heart tumors are described, as well as its natural history and its complications to analyze its behavior during two different periods along 20 years. METHODS: Study was developed in two stages. In the first one a total of 1,884 pregnants between 18 and 22 gestational weeks were studied who were seen in consultation due to different obstetric risk factors. The technique applied was similar to that at worldwide using (mas) a equipment Combison 320-5 and Aloka 860 and electronic transducers of 3,5 and 5 MHz, and color coded Doppler to study the intracavitary flux and the pressure gradient. RESULTS: Six cardiac tumors were identified representing the 0,3% of study cases. Five were rhabdomyosarcomas, and one was a right atrium myxoma. Most blockade the inlet and outlet tracts. There was an arrhythmia in a case. Sensibility and specificity rates were of 100% and 99,8%, respectively. CONCLUSIONS: It was shown the poor frequency of fetal cardiac tumors and the significance of echocardiography by its high sensibility and specificity rate.

Scientific Electronic Library Online (Spanish)

16

Presiones medidas en la base de una losa de fondo con juntas paralelas al flujo en un canal/ Measured pressures on the basis of bottom slab with gaps in the flow direction in a channel

Hurtado Orobio, Edwin; del Risco Moreno, Efraín; González Betancourt, Mauricio
2009-03-01

Resumen en español Se estudió si las aristas traseras de las juntas longitudinales de una losa de piso, fija al fondo de un canal con flujo supercrítico, convierten energía cinética en energía de presión en el rango de números de Froude de 2,84 a 10,12. En cada prueba, se midió la presión en 16 puntos de su cara inferior, con transductores piezoresistivos en tres líneas longitudinales: una central con 8 sensores y dos laterales, a lado y lado de la primera, con cuatro sensores cad (mas) a una. De esta forma, se determinó la distribución de las presiones medias debajo de la losa ensayada, similar a las usadas en obras civiles para evitar la acción erosiva de la turbulencia de un flujo supercrítico. El análisis de las presiones medidas muestra que, aún cuando las caras superiores del piso del canal y del bloque protector estén en el mismo plano horizontal, las aristas traseras de las juntas longitudinales transforman energía de velocidad en energía de presión. Así, se ha detectado un factor que interviene en la generación de la fuerza hidrodinámica que levanta revestimientos de diverso tipos de estructuras, hasta ahora ignorado en el estudio de este problema. Resumen en inglés A study was conducted to determine whether the back edges of the longitudinal gaps of a floor tile fixed to the bottom of a canal with a supercritical flow convert kinetic energy into pressure energy using Froude numbers in the range of 2.84 to 10.12. In each test the pressure was measured on 16 points on the bottom surface of the tile with piezo-resistive transducers along three longitudinal lines: one central line with 8 sensors and two lateral lines with 4 sensors each (mas) on either side of the central line. In this manner the distribution of the median pressures under the test tile was determined. The test tile is similar to those used in civil engineering structures for the purpose of avoiding the erosive action of the turbulence of a supercritical flow. The analysis of the measured pressures shows that even when the top surfaces of the canal floor and of the protective block are in the same horizontal plane, the back edges of the longitudinal gaps transform the energy of velocity into pressure energy. In such a way a factor has been identified that intervenes in the production of the hydrodynamic force that lifts revetments of different structures, and that has until now been ignored in the study of this problem.

Scientific Electronic Library Online (Spanish)

17

Diseño de un instrumento para medir la fuerza ejercida sobre el disco de un estabilizador magnético/ DESIGN OF A DEVICE TO MEASURE THE POWER PERFORMED ON A MAGNETIC STABILIZER DISK

Subero, Karla
2008-07-01

Resumen en español Como es bien sabido los helicópteros monorotores se estabilizan en vuelo por medio de un rotor secundario instalado en el extremo de su cola. El estabilizador magnético consiste en un sistema novedoso que funciona por corrientes parásitas inducidas por un campo magnético giratorio que, actuando sobre un disco de material paramagnético, genera el torque de estabilización necesario. Este dispositivo tiene forma circular por lo que puede instalarse debajo del piso del (mas) helicóptero. Eliminando la cola es posible modificar oportunamente la estructura y el aspecto convencional que tienen los helicópteros monorotores. El propósito de este artículo es establecer las bases técnicas y el procedimiento requerido para diseñar e implementar un instrumento que permita mostrar al piloto de la aeronave el par mecánico generado, la velocidad angular del estabilizador y la separación entre campos magnéticos y disco paramagnético. Para lograr el diseño se ha recurrido a las técnicas modernas de diseño electrónico y de desarrollo de microcontroladores. Para la implementación y prueba del equipo se han utilizados transductores de “momento”, de “velocidad angular”, de “distancia” y se han desarrollado los programas computacionales para el uso de microcontroladores PIC. En laboratorio se han montado e instrumentado adecuadamente los circuitos de prueba necesarios para asegurar el buen funcionamiento del instrumento. Los resultados obtenidos han sido satisfactorios, como se concluye al final de este articulo. Resumen en inglés As well known, monorotor helicopter needs a secondary rotor in his tail to stabilize his flight. A magnetic stabilizer is a new device that, by a turning magnetic field, induces eddy currents on a paramagnetic disk that generates the mechanical momentum necessary to stabilize the helicopter. This new device has circular form and may be installed down the flour of airship. Eliminating the tail, the conventional structure and form of monorotor helicopter may be conveniently (mas) modified. The proposal of this paper is to describe the necessary technical bases and the procedure to design and implement a cockpit instruments required by the airship pilot to know the angular velocity, the intensity of mechanical momentum generated by stabilizer and the separation between magnetic field and paramagnetic disk. To design the instrument, modern procedures of electronic design and development of microcontrollers have been used. To implement the equipment and test it, momentum, velocity and distance transducers have been used. Computational program for microcontroller PIC have been developed. In the laboratory, all electronic circuits have been tested with the proper instrumentation. Results have been satisfactory as we conclude to the end of this paper.

Scientific Electronic Library Online (Spanish)

18

Punción con aguja fina guiada por ultrasonido en metástasis axilares de cáncer de mama

Uribe, Jorge R; Hernández, Carlos A; Menolascino, Francisco; Márquez, María E; Rodríguez, Joel E; Istúriz, Linda M; Rodríguez, Ramón E; Uribe, Jorge L
2010-09-01

Resumen en español OBJETIVO: Presentar nuestra experiencia en la utilización de la punción con aguja fina ecoguiada en identificación de metástasis axilares en pacientes con cáncer de mama. MÉTODO: Nuestra experiencia en 399 pacientes, evaluados desde enero de 2007 hasta julio de 2009. El protocolo impone la realización de una punción ecoguiada de cualquier ganglio axilar sea sospechoso o no. Se utilizan equipos de ultrasonido dedicados únicamente para la exploración de la mama, c (mas) on transductores multifrecuenciales, empleo del software del equipo de manera particular al momento de la exploración de la axila, que permite mejorar la imagen ecográfica de esa zona. RESULTADOS: En 55,89 % (223/399) se identificaron ganglios axilares por ultrasonido, y se les practicó la punción con aguja fina a un 51,12 % (114/223) se les identificó una metástasis axilar. En un 41,26 % (92/223) esta punción fue negativa y en un 7,62 % (17/223) no fue concluyente. Se diagnosticó metástasis en 34,61% (9/26) de tumores T1, 46,6 % (42/90) de T2. Cuando el tamaño del tumor fue determinado por ultrasonido, se identificó metástasis axilar en 40,00 % (32/80) de los T1 y 57,8 % (59/102) de los T2. CONCLUSIONES: La experiencia ganada, sumado al adecuado manejo de la tecnología de los equipos de ultrasonido, nos ha permitido identificar con mayor frecuencia los ganglios axilares en estas pacientes. Es importante estudiarlos independiente de su característica morfológica, pues las células metastásicas pueden estar presentes sin ocasionar alteración alguna en su apariencia ecográfica. Resumen en inglés OBJECTIVE: In this work we present our updated experience on the fine needle aspiration puncture in patients with breast cancer. METHOD: Our experience in 399 patients with breast cancer, evaluated from january 2007 through july of 2009. The protocol of this work imposes a puncture ecoguide at any axillaries lymph node, were suspicion or not. Ultrasound equipment is used solely dedicated to the exploration of the breast, transducers multifrecuenciales and use of software (mas) in a particular way when the exploration of the axils needed and to improve the ultrasound image of the area. RESULTS: In 55.89 % of patients (223/399) axillaries lymph nodes were identified for ultrasound and underwent fine needle aspiration puncture. Of the 223 patients 51.12 % (114/223) metastases was identified. 1.26 % (92/223) fine needle puncture was negative in 7.62% (17/223) was suggestive but not conclusive. Regarding clinical tumor size, the metastases diagnosis was 34.61 % (9 / 26) of T1 and 46.6 % (42/90) of T2 tumors. When the tumor size was determined by ultrasound, the axillaries metastases were identified in 40.00 % (32/80) of T1 size tumors and 57.8 % (59/102) of T2. CONCLUSIONS: The gained experience, added to proper management of the ultrasounds equipment, has allowed us to identify more frequently in those patients axillaries lymph nodes. It is important to study the nodes independently of their morphological characteristics, as the metastatic cells may be present without causing any alteration in appearance ultrasonic graphically.

Scientific Electronic Library Online (Spanish)

19

Ultrasonidos extracorpóreos de alta intensidad: alternativa terapéutica del tumor renal/ Extracorporeal high-intensity focused ultrasound: Therapeutic alternative for renal tumors

Caballero, J.M.; Borrat, P.; Paraira, M.; Martí, L.; Ristol, J.
2010-05-01

Resumen en español Objetivos: Es conocida la aplicación de los ultrasonidos focalizados de alta intensidad (HIFU) en el tratamiento de los tumores sólidos dentro de las terapias mínimamente invasivas, habiéndose desarrollado en los últimos años transductores que permiten la aplicación de ultrasonidos desde un foco extracorpóreo. Presentamos una revisión del desarrollo, los principios físicos, el estado actual y la experiencia inicial propia de esta terapia en el tratamiento de los (mas) tumores renales. Material y métodos: Actualmente el HIFU extracorpóreo está siendo utilizado en el tratamiento de tumores, principalmente hepáticos, ginecológicos y óseos, y se ha iniciado su uso en la terapia para las neoplasias renales con buenos resultados. Presentamos una revisión bibliográfica (búsqueda estructurada en la base electrónica MEDLINE online) de los principios físicos de este tratamiento y su acción biológica. Describimos la metodología de tratamiento de los primeros casos de carcinoma renal tratados en nuestro hospital con éxito mediante HIFU. Resultados: Esta terapia ha sido empleada con éxito para tratar tumores sólidos en varios centros de Europa, América y Asia. En nuestro centro tenemos una amplia experiencia en el tratamiento mediante HIFU extracorpóreo de tumores ginecológicos, y ya hemos tratado tumores renales sin complicaciones, si bien el seguimiento es todavía corto. Conclusiones: El uso de esta energía de forma extracorpórea aparece como una nueva opción dentro de las terapias no invasivas del cáncer renal en casos seleccionados, con un escaso índice de complicaciones, aunque hace falta mucho más tiempo de seguimiento para valorar sus resultados desde el punto de vista oncológico. Resumen en inglés Objectives: High intensity focused ultrasound (HIFU) is known to be used for the treatment of solid tumors in minimally invasive procedures. Transducers allowing for application of ultrasound from an extracorporeal focus have recently been developed. A review is provided of the development, physical principles, and current status of this therapy, and our early experience with it for the treatment of renal tumors is reported. Materials and methods: Extracorporeal HIFU is c (mas) urrently being used for the treatment of tumors (mainly hepatic, gynecological, and bone tumors), and has been started to be used for renal tumors with good results. A literature review (structured search in the online MEDLINE electronic base) of the physical principles of this treatment and its biological action is provided. The therapeutic procedure used in the first few patients with renal carcinoma successfully treated with HIFU at our hospital is reported. Results: This therapy has been successfully used to treat solid tumors at several centers in Europe, America, and Asia. Our center has a wide experience in treatment of gynecological tumors using extracorporeal HIFU, and has already treated renal tumors with no complications, although follow-up is still short. Conclusions: Extracorporeal use of this energy appears as a new option among non-invasive therapies for renal cancer in selected cases. A low complication rate has been noted, but much longer follow-up times are required for assessment of oncological results.

Scientific Electronic Library Online (Spanish)

20

Relación entre presión y volumen para la implementación de la técnica in vitro de producción de gases en Medellín, Colombia/ Relationship between pressure and volume for the implementation of the gas production technique, in vitro, in Medellín, Colombia.

Posada, Sandra L; Noguera, Ricardo; Bolívar, Diana
2006-12-01

Resumen en español La técnica de producción de gases es un método in vitro que permite determinar la extensión y la cinética de degradación del alimento mediante el volumen de gas producido durante el proceso fermentativo. La cuantificación de los gases puede realizarse mediante el empleo de transductores que miden la presión originada por los gases acumulados en la parte superior de los frascos de fermentación. El objetivo de este trabajo fue establecer una ecuación de regresión (mas) que relacione presión (P) y volumen de gas (V), para la implementación de la técnica de producción de gases, in vitro, en las condiciones de altura sobre el nivel del mar, del laboratorio de Biotecnología Ruminal (UN, sede Medellín, 1538 msnm). Para este propósito se utilizaron seis forrajes diferentes, que fueron inoculados con líquido ruminal y heces provenientes de vacas Holstein. La presión generada por los gases acumulados en la parte superior de los frascos de incubación fue medida con un transductor de presión conectado a un lector digital. El volumen de gas fue determinado mediante extracción con jeringa hasta el momento en que la presión registrada en el lector fue cero. La ecuación fue obtenida utilizando PROC REG del programa estadístico SAS y correspondió a: V= -0.1375+(5.1385*P)+(0.0777*P2), R2 = 0.99. El establecimiento de esta ecuación es necesario, puesto que la ley general de gases de Boyle y Gay-Lussac no permite estimar el volumen de gas diluido en la fase líquida. De igual manera el volumen de gas acumulado en la parte superior de los frascos varía en función de la presión atmosférica, lo que hace necesario el ajuste. La ecuación obtenida es representativa de las dos fuentes de inóculo y de una amplia gama de sustratos forrajeros con diferente potencial de fermentación. Así se consolida la utilización de esta ecuación en futuros trabajos de investigación. Resumen en inglés The in vitro gas production technique is a method that allows the determination of the extent and kinetics of degradation of food as a function of the gas volume obtained during fermentation. Gas quantification can be done with the use of transducers measuring the pressure originated by the gas in fermentation flasks. The objective of this work was to establish a regression equation that relates gas pressure (P) and volume (V), for the implementation of in vitro gas produ (mas) ction technique, according to the height over the sea level condition of our laboratory, in Medellín, Colombia. For this purpose, six different tupes of forage were inoculated with ruminal liquor and feces from Holstein cows. The pressure generated by the gas accumulated in the upper part of the incubation flasks was measured through a pressure transducer connected to a digital reader. Gas was extracted with a syringe until the pressure registered in the reader was zero. The equation was obtained using PROC REG of the SAS program: V = -0,1375+(5,1385*P)+(0,0777*P2), R² = 0,99. Establishing this equation is necessary because the Boyle and Gay-Lussac´s law doesn’t allow the estimation of the volume of gas diluted in the liquid phase. Similarly, the volume of gas accumulated in the upper part of the flasks varies as a function of the atmospheric pressure, therefore demanding the respective adjustment. The obtained equation is representative for ruminal liquor, feces and a wide range of forages with different fermentation potential. Thus, the equation was standardized for future research.

Scientific Electronic Library Online (Spanish)

21

Expresión génica en pacientes obesos con enfermedad hepática por depósito de grasa/ Gene expression in obese patients with non-alcoholic steatohepatitis

Cayón, A.; Crespo, J.; Guerra, A. R.; Pons-Romero, F.
2008-04-01

Resumen en español La fisiopatología de la enfermedad hepática por depósito de grasa sólo se conoce de forma parcial. En este trabajo hemos analizado la expresión génica intrahepática de citoquinas, quimioquinas, receptores celulares, factores de crecimiento, transductores de señales intracelulares y proteínas de comunicación extracelular en el tejido hepático de sujetos obesos con y sin esteatohepatitis no alcohólica, en un intento de determinar un perfil de expresión génica (mas) asociado a las formas severas de la esteatohepatitis no alcohólica (EHNA). Se analizó un grupo de 38 pacientes obesos con un IMC > 35, que fueron sometidos a cirugía bariátrica. La expresión génica intrahepática se determinó en el tejido hepático dividiendo a los pacientes en tres grupos: a) pacientes obesos sin datos histológicos sugestivos de EHNA (n = 12); b) pacientes con EHNA sin fibrosis (n = 13); y c) pacientes con EHNA y fibrosis (n = 13). Se consideró que existía una sobreexpresión génica cuando la diferencia en la expresión era, al menos, de dos veces con respecto al grupo control. Los resultados se confirmaron mediante PCR en tiempo real. Se detectó una expresión diferencial de 14 genes (10 sobreexpresados y 4 infraexpresados). Los genes sobreexpresados incluyeron prohibitina, TNF, TNF RI (p55), MCSF, R2-TRAIL, TGF-b1, CTGF, FGF, VEGF, BIGH3 y ObRb. La expresión de los genes insulin growth factor-1, insulin growth factor-2, interleuquina-2 y tyrosine-receptor fue menor que en el grupo control. En conclusión: 1. Los pacientes obesos con EHNA sin fibrosis muestran una sobreexpresión de genes proinflamatorios y proapoptóticos. En los pacientes con EHNA y fibrosis, se observa, además, una sobreexpresión de genes profibrogénicos, incluyendo el gen del receptor de la leptina. 2. La expresión de prohibitiva en los pacientes con EHNA, tanto con fibrosis como sin fibrosis, fue superior que en los controles, lo que sugiere una disfunción mitocondrial en los pacientes con EHNA. Resumen en inglés Although the molecular basis for the pathophysiology of non-alcoholic steatohepatitis (NASH) is poorly understood, we evaluate the hepatic gene expression of cytokines, chemokines, cell receptors, growth factors, intracellular transducers and extracellular communication proteins in liver tissue of obese patients (with and without NASH), and we determine the specific intrahepatic gene expression profiles associated with histological severe NASH. Thirty-eight obese patients (mas) with BMI > 35 were analyzed, who underwent bariatric surgery. Biopsy specimen samples were snap-frozen in liquid nitrogen. Hepatic gene expression was determined in liver biopsy specimens from 3 groups: a) obese patients without NASH (n = 12); b) patients with NASH without fibrosis (n = 13); and c) patients with NASH and fibrosis (n = 13). Genes were considered to be expressed differentially in NASH only if there was a greater than 2-fold difference in abundance of mRNA when compared with each of the control group. These results were confirmed by real-time PCR. Fourteen genes were differentially expressed (10 overexpressed and 4 underexpressed) in patients with NASH. Genes that were significantly overexpressed included prohibitin, TNF, TNF RI (p55), MCSF, R2-TRAIL, b1-CTGF, FGF, VEGF, and BIGH3OBR. Insulin growth factor-1, insulin growth factor-2, interleukin-2 and tyrosine-receptor were underexpressed in NASH patients. In conclusion: 1. The obese patients with NASH without fibrosis show an overexpression of proinflammatory and proapoptotic genes. Also, the NASH patients with fibrosis show an overexpression of fibrogenic genes, including the leptin receptor Ob-Rb. 2. The up-regulated gene expression of prohibitin suggests mitochondrial dysfunction in NASH patients.

Scientific Electronic Library Online (Spanish)

22

¿Existe en la constipación idiopática severa un trastorno difuso de la motilidad intestinal?/ Disturbances of small intestinal motility in patients with chronic constipation

Madrid S, Ana María; Defilippi C, Carlos
2006-02-01

Resumen en inglés Background: Studies in patients with chronic severe constipation, suggest the presence of a diffuse motor disorder of the gastrointestinal tract. Aim: To investigate small bowel motor activity in a group of patients with severe constipation. Material and Methods: Forty three patients (age range 13 to 70 years, 40 women) with severe constipation referred to our motility laboratory, where studied. Ten had a previous colectomy. Radiological examinations showed a megacolon in (mas) 30 and dilatation of small intestinal loops in nine; the remaining X rays studies were normal. Small intestinal motility was studied using perfused catheters and external transducers. Results: Ten patients had normal motor recordings. Eight patients showed a neuropathic disorder characterized by a continuous irregular pattern of contractions of normal amplitude, with absence of phase III of the migrating motor complex (MMC). Sixteen presented a normal MMC associated to a decreased amplitude of contractions (Miopatic disorder). Nine showed both types of motor disorders (Mixed pattern). Normal radiological findings were more commonly associated to normal manometric recordings. By contrast, an altered motor activity, mainly of myopathic and mixed type motor disorder, was observed in all patients with dilated small intestinal and colonic loops. Conclusions: The presence of small intestinal motor disorders was a frequent finding in this selected group of patients with chronic constipation

Scientific Electronic Library Online (Spanish)

23

Waveform Shaping of Sonar Transducers for Improving the Vertical Resolution in Sub-bottom Sediments Profiling

Cobo, Pedro; Ranz Guerra, Carlos; Fernández, Alejandro; Anthony, David K.; Siguero, Manuel

Final full-text version of the paper available at SpringerLink: http://dx.doi.org/10.1007/s11001-005-3709-6. | Vertical resolution is of fundamental importance in sonar exploration and is directly related to the duration of the acoustic pulse generated by the transducer. The shorter the radiated pul...

DRIVER (Spanish)

24

Waveform Shaping of Sonar Transducers for Improving the Vertical Resolution in Sub-bottom Sediments Profiling

Cobo, Pedro; Ranz Guerra, Carlos; Fernández, Alejandro; Anthony, David K.; Siguero, Manuel
2005-06-01

Digital.CSIC (Spain)

25

Valor de la manometría intestinal en la patología gastrointestinal/ Small intestinal manometry in gastrointestinal disorders

Madrid S, Ana María; Quera P, Rodrigo; Defilippi C, Carlos
1999-10-01

Resumen en inglés Background: Small intestinal manometry is a relatively simple technique. However, its use is usually limited to very few centers and mainly related to research studies. Aim: To report our experience with small intestinal motility studies in a group of normal controls and patients with symptoms suggesting a gastrointestinal motor disorder. Patients and methods: Seventy three studies were performed in 71 subjects: 18 asymptomatic controls and 55 patients presenting with sym (mas) ptoms characterized by abdominal pain, vomiting, bloating, constipation and diarrhea. In 33 patients the same symptoms remained without diagnosis, in spite of extensive laboratory studies. In 10 of these, dilated small intestinal loops were observed and intestinal pseudoobstruction was suspected. Twenty two additional patients with systemic disorders such as scleroderma, diabetes and previous vagotomies, were studied. Motility was assessed by means of perfused catheters connected to external transducers for a mean lapse of 280 min. Results: An abnormal pattern of small intestinal motility suggesting neuropathic, myopathic or a mixed disorder was observed in 76% of all studied patients, with the exception of patients with scleroderma, in whom only myopathic and mixed alterations were observed. In 82% of patients, the results of manometry were useful for the management of the clinical condition. Conclusions: small intestinal manometry is a relatively simple technique that, when used in selected groups of patients, provides useful information for clinical management

Scientific Electronic Library Online (Spanish)

26

Ultrasound device for improving the solid-liquid separation process in suspensions.

Gallego Juárez, Juan Antonio; Rodríguez, Corral; Elvira Segura, Luis
2006-12-16

Digital.CSIC (Spain)

27

Ultrasonic transduction system for imaging with a low number of transducers located at different planes

Rodríguez, Miguel A.; Ramos, Antonio; San Emeterio, José Luis

Ponencia presentada en el XIX Congreso Internacional de Acústica (ICA2007), Madrid, 2-7 Sep 2007.-- PACS: 43.35Zc. | A new transduction system for obtaining ultrasonic images of flaws in pieces accessible from two external planes, using a very low number of piezoelectric transducers, is analysed. Th...

DRIVER (Spanish)

29

Two-dimensional modelling of multifrequency piezocomposites

Lamberti, N.; Montero de Espinosa Freijo, Francisco; Iula, A.; Carotenuto, R.
2000-01-01

Digital.CSIC (Spain)

30

Two-dimensional Modeling of Multifrequency Composites

Lamberti, N.; Montero de Espinosa Freijo, Francisco; Sánchez, S.; lula, A.; Pappalardo, M.
1995-01-01

Digital.CSIC (Spain)

31

Towards fully integrated wireless impedimetric sensors

Segura-Quijano, Fredy; Sacristán-Riquelme, Jordi; García-Cantón, Jesús; Osés, María Teresa; Baldi Coll, Antonio
2010-04-21

Digital.CSIC (Spain)

32

Time domain analysis of ultrasonic signals for non-invasive temperature estimation

Salido, Ricardo; Bazán, Ivonne; Ramos, Antonio; Vera, Arturo; Leija, Lorenzo
2007-12-01

Digital.CSIC (Spain)

33

The G protein-coupled receptor regulatory kinase GPRK2 participates in Hedgehog signaling in Drosophila

Molnar, Cristina; Holguín, Helena; Mayor Menéndez, Federico; Ruiz-Gómez, Ana; de Celis, Jose F.
2007-05-01

Digital.CSIC (Spain)

35

Spatial patterns of the transient ultrasonic field radiated by a dual-transducer NDE probe

Azbaid, Abdelhalim; Ramos, Antonio; San Emeterio, José Luis; Sanz Sánchez, Pedro Tomás

6 pages, 4 figures.-- PACS nrs.: 43.35, 43.38, 43.20.-- Communication presented at: Forum Acusticum Sevilla 2002 (Sevilla, Spain, 16-20 Sep 2002), comprising: 3rd European Congress on Acoustics; XXXIII Spanish Congress on Acoustics (TecniAcústica 2002); European and Japanese Symposium on Acoustics; ...

DRIVER (Spanish)

36

Spatial patterns of the transient ultrasonic field radiated by a dual-transducer NDE probe

Azbaid, Abdelhalim; Ramos, Antonio; San Emeterio, José Luis; Sanz Sánchez, Pedro Tomás
2002-09-01

Digital.CSIC (Spain)

37

Sound propagation and bubble motion in a cavitating channel

Mettin, Robert; Claussen, Jann-Ohle; Campos-Pozuelo, Cleofé
2007-12-01

Digital.CSIC (Spain)

38

Sistema Automático de Ocho Canales para la Medida de Velocidad de Propagación en Líquidos por Ultrasonidos

Montero de Espinosa Freijo, Francisco; Higuti, R. T.; Curpián Alonso, José
2000-10-01

Digital.CSIC (Spain)

40

Simulating Echo Responses from Arbitrary-Geometry Targets Using Mode Conversion Approach

Buiochi, Flávio; Martínez Graullera, Óscar; Gómez-Ullate Alvear, Luis; Montero de Espinosa Freijo, Francisco
2008-01-01

Digital.CSIC (Spain)

41

Simulación de composites piezoeléctricos

Montero de Espinosa Freijo, Francisco; Rodríguez, F.; Gómez Álvarez-Arenas, Tomás
1998-06-01

Digital.CSIC (Spain)

42

Sand/Cement ratio evaluation on mortar using neural network and ultrasonic transmission inspection

Molero, M.; Hernández, M. G.; Izquierdo, M. A. G.; Fuente, J. V.; Anaya Velayos, José Javier
2009-01-01

Digital.CSIC (Spain)

44

Remote unit for mobile-telephony telemetering for distributed ultrasonic transducers

Rodríguez, Miguel A.; Sanz Sánchez, Pedro Tomás; Zaplana, David; Ramos, Antonio; San Emeterio, José Luis

6 pages, 5 figures.-- PACS nrs.: 43.35, 43.38, 84.40.-- Communication presented at: Forum Acusticum Sevilla 2002 (Sevilla, Spain, 16-20 Sep 2002), comprising: 3rd European Congress on Acoustics; XXXIII Spanish Congress on Acoustics (TecniAcústica 2002); European and Japanese Symposium on Acoustics; ...

DRIVER (Spanish)

45

Remote unit for mobile-telephony telemetering for distributed ultrasonic transducers

Rodríguez, Miguel A.; Sanz Sánchez, Pedro Tomás; Zaplana, David; Ramos, Antonio; San Emeterio, José Luis
2002-09-01

Digital.CSIC (Spain)

46

Ras-Guanine Nucleotide Exchange Factor Sos2 Is Dispensable for Mouse Growth and Development

Esteban, Luis Miguel; Fernández-Medarde, Alberto; López, Eva; Yienger, Kate; Ward, Jerrold M.; Tessarollo, Lino; Santos de Dios, Eugenio; Guerrero Arroyo, María del Carmen
2000-09-01

Digital.CSIC (Spain)

47

Radiating Wideband Sonar Pulses with Resonant Sandwich Transducers by Designing the Driving Voltage Waveform

Cobo Parra, Pedro; Ranz Guerra, Carlos; Siguero Guerra, Manuel

Communication presented at the 17th International Congress on Acoustics, Rome, 2-7 September 2001. | A technique to radiate short length, high resolution, pulses with conventional piezoelectric transducers is described. It consists on designing the driving voltage waveform so that the radiated pulse...

DRIVER (Spanish)

49

Prototype for the use of ultrasound in supercritical media

Riera, Enrique; Blanco Blanco, Alfonso; Acosta Aparicio, Víctor Manuel; Gallego Juárez, Juan Antonio; Blasco Piquer, Miguel; Mulet Pons, Antonio
2007-12-01

Digital.CSIC (Spain)

51

Prevalencia de los diferentes trastornos motores primarios del esófago: Estudio prospectivo de 5.440 casos/ Primary esophageal motor disturbances among patients with esophageal symptoms

Henríquez D, Ana; Csendes J, Attila; Rencoret P, Guillermo; Braghetto M, Ítalo
2007-10-01

Resumen en inglés Background: The esophagus can suffer several motor disturbances of striated or smooth muscle. Aim: To determine the presence of primary motor disturbances of the esophagus among a group of patients with esophageal symptoms. Material and methods: Prospective study of 5,440 patients consulting for heartburn, chest pain or dysphagia, with primary esophageal motor disturbances, studied between 1994 and 2004. AH were subjected to an esophageal manometry with eight perfused cat (mas) heters connected to pressure transducers. Results: Nineteen percent of subjects had a normal esophageal manometry, 60% had unspecific motor disturbances usually associated to gastroesophageal reflux, 13% had a nutcracker esophagus, 5% had diffuse esophageal spasm, 2% had achalasia and 0,3% had an hypertensive sphincter. Conclusions: Primaryesophageal motor disturbances are common among patients with esophageal symptoms. A manometry should be performed to these patients

Scientific Electronic Library Online (Spanish)

52

Power mesurement of airbone ultrasonic transducers

Chinchurreta, Francisco José; Hekkenberg, Rob; Montero de Espinosa Freijo, Francisco

Ponencia presentada en el XIX Congreso Internacional de Acústica (ICA2007), Madrid, 2-7 Sep 2007.-- PACS: 43.58 Vb. | The use of radiation force balances is the standardized method for the measurement of ultrasonic power in water, IEC-EN 61161 Ed1. This paper presents and discusses the application o...

DRIVER (Spanish)

53

Power mesurement of airbone ultrasonic transducers

Chinchurreta, Francisco José; Hekkenberg, Rob; Montero de Espinosa Freijo, Francisco
2007-12-01

Digital.CSIC (Spain)

54

Plasma-activated multi-walled carbon nanotube–polystyrene composite substrates for biosensing

Fernández Sánchez, César; Pellicer, Eva; Orozco, Jahir; Jiménez-Jorquera, Cecilia; Lechuga, Laura M.; Mendoza Gómez, Ernest
2009-08-01

Digital.CSIC (Spain)

55

Piezoelectric transducers for air-coupled operation in the frequency range 0.3-2.5 MHz

Gómez Álvarez-Arenas, Tomás; Montero de Espinosa Freijo, Francisco

6 pages, 4 figures.-- PACS nrs.: 43.38.Ar, 43.38.Fx.-- Communication presented at: Forum Acusticum Sevilla 2002 (Sevilla, Spain, 16-20 Sep 2002), comprising: 3rd European Congress on Acoustics; XXXIII Spanish Congress on Acoustics (TecniAcústica 2002); European and Japanese Symposium on Acoustics; 3...

DRIVER (Spanish)

56

Piezoelectric transducers for air-coupled operation in the frequency range 0.3-2.5 MHz

Gómez Álvarez-Arenas, Tomás; Montero de Espinosa Freijo, Francisco
2002-09-01

Digital.CSIC (Spain)

57

PSPICE simulation of transient responses of transducers and spike generators included in E/R ultrasonic systems

Ruiz Toledo, Abelardo; Ramos, Antonio; San Emeterio, José Luis; Sanz Sánchez, Pedro Tomás

6 pages, 9 figures.-- PACS nrs.: 43.35, 43.38.-- Communication presented at: Forum Acusticum Sevilla 2002 (Sevilla, Spain, 16-20 Sep 2002), comprising: 3rd European Congress on Acoustics; XXXIII Spanish Congress on Acoustics (TecniAcústica 2002); European and Japanese Symposium on Acoustics; 3rd Ibe...

DRIVER (Spanish)

58

PSPICE simulation of transient responses of transducers and spike generators included in E/R ultrasonic systems

Ruiz Toledo, Abelardo; Ramos, Antonio; San Emeterio, José Luis; Sanz Sánchez, Pedro Tomás
2002-09-01

Digital.CSIC (Spain)

59

On Estimating Concrete Porosity by Ulrasonic Non-Destructive Testing

Vergara, L.; Miralles, R.; Gosálbez, J.; Juanes, F. J.; Gómez-Ullate, Luis; Anaya Velayos, José Javier

DRIVER (Spanish)

60

On Estimating Concrete Porosity by Ulrasonic Non-Destructive Testing

Vergara, L.; Miralles, R.; Gosálbez, J.; Juanes, F. J.; Gómez-Ullate Alvear, Luis; Anaya Velayos, José Javier; González Hernández, Margarita; García Izquierdo, Miguel Ángel
2001-09-01

Digital.CSIC (Spain)

61

Novel routes for inter-matrix synthesis and characterization of polymer stabilized metal nanoparticles for molecular recognition devices

Muraviev, Dmitri N.; Macanás, Jorge; Farré Urgell, Marinel.la; Muñoz, María; Alegret, Salvador

10 pages, 7 figures, 1 table.-- Printed version published Oct 25, 2006.-- Issue title: "Eurosensors XIX - The 19th European Conference on Solid-State Transducers" | This paper reports the results obtained by development of novel approaches for inter-matrix synthesis and characterization of polymer s...

DRIVER (Spanish)

62

Novel routes for inter-matrix synthesis and characterization of polymer stabilized metal nanoparticles for molecular recognition devices

Muraviev, Dmitri N.; Macanás, Jorge; Farré Urgell, Marinel.la; Muñoz, María; Alegret, Salvador
2006-05-23

Digital.CSIC (Spain)

63

Non linear down-frequency conversion effects in high intensity Vibration of plate transducers and piezoelectric structures

Alippi, Adriano; Bettucci, Andrea; Biagioni, Angelo; Gallego Juárez, Juan Antonio; Passeri, Daniele

Ponencia presentada en el XIX Congreso Internacional de Acústica (ICA2007), Madrid, 2-7 Sep 2007.-- PACS: 43.55.Cs. | Driving airborne ultrasound plate transducers at high intensity levels is an important point in many industrial applications, that meets with unavoidable limits due to nonlinear moda...

DRIVER (Spanish)

64

Non linear down-frequency conversion effects in high intensity Vibration of plate transducers and piezoelectric structures

Alippi, Adriano; Bettucci, Andrea; Biagioni, Angelo; Gallego Juárez, Juan Antonio; Passeri, Daniele; Riera, Enrique
2007-12-01

Digital.CSIC (Spain)

65

Nanobiosensors based on optoelectronic and nanomechanical transducers for genomic and proteomic applications

Lechuga, Laura M.; Tamayo, Javier; Calle Martín, Ana; Domínguez, Carlos
2006-02-01

Digital.CSIC (Spain)

66

Murine hematopoietic reconstitution after tagging and selection of retrovirally transduced bone marrow cells.

García-Hernández, B.; Castellanos, A.; López, A.; Orfao, A.; Sánchez García, Isidro
2007-01-01

Digital.CSIC (Spain)

67

Multiplexing and transmission of RF signals using an optical fiber

Curpián Alonso, José; Montero de Espinosa Freijo, Francisco; López-Amo, Manuel
2000-03-01

Digital.CSIC (Spain)

68

Multifrequency piezoelectric composites: one-dimensional modeling

Sánchez, S.; Montero de Espinosa Freijo, Francisco; Lamberti, N.

Final full-text version of the paper available at: http://www.sciencedirect.com/science/journal/0041624X. | It has been proposed that multifrequency piezoelectric composites increase the bandwidth of the standard piezocomposite configurations. The geometrical approach consists of the use of piezoele...

DRIVER (Spanish)

69

Multifrequency piezoelectric composites: one-dimensional modeling

Sánchez, S.; Montero de Espinosa Freijo, Francisco; Lamberti, N.
1999-02-01

Digital.CSIC (Spain)

72

Materiales y técnicas para el acoplamiento mecánico óptimo de piezocerámicas en aire

Montero de Espinosa Freijo, Francisco; Gómez Álvarez-Arenas, Tomás
2002-01-01

Digital.CSIC (Spain)

73

Macrosonics: Phenomena, transducers and applications

Gallego Juárez, Juan Antonio

15 pages, 17 figures.-- PACS nrs.: 43.35; 43.25.-- Communication presented at: Forum Acusticum Sevilla 2002 (Sevilla, Spain, 16-20 Sep 2002), comprising: 3rd European Congress on Acoustics; XXXIII Spanish Congress on Acoustics (TecniAcústica 2002); European and Japanese Symposium on Acoustics; 3rd I...

DRIVER (Spanish)

79

La ultrasonografía en reumatología: un antes y un después/ Before and after sonography is applied in rheumatology

Naredo Sánchez, Esperanza
2007-06-01

Resumen en español La ultrasonografía es una técnica diagnóstica y terapéutica de relativamente reciente introducción en reumatología, en vertiginoso desarrollo tecnológico y en pleno auge en cuanto a aplicación clínica e investigación. Su empleo ha sido posterior al de otras especialidades porque los medios técnicos necesarios para obtener imágenes de suficiente calidad del aparato locomotor comenzaron a desarrollarse a finales de los años 80, con la fabricación de las sondas (mas) lineales de alta frecuencia-alta resolución actualmente disponibles. Con la ecografía la deducción diagnóstica clásica se ha hecho más profunda porque esta técnica nos permite ver lo que está ocurriendo debajo de la piel, en los tendones, músculos y articulaciones, sin dañar al paciente. Por ello, es una herramienta idónea en la práctica diaria del reumatólogo ya que se convierte en una extensión de la exploración física en lugar de una exploración complementaria convencional más. La ecografía es una técnica válida y fiable para el estudio de las estructuras periarticulares e intraarticulares implicadas en las enfermedades reumatológicas. Es relativamente económica, inocua, rápida, repetible, dinámica y bien aceptada por el paciente. Se realiza en tiempo real en la misma consulta, permitiendo una correlación inmediata entre los datos clínicos y las imagenes del paciente. Finalmente, una aplicación esencial es la ecografía intervencionista, en la que podemos guiar las punciones diagnósticas y/o terapéuticas del aparato locomotor mediante la visualización del trayecto de las agujas de punción en la pantalla, con lo que conseguimos el alcance preciso y seguro de la lesión. Resumen en inglés Within the last 20 years, the development of high frequency transducers, which have greatly improved musculoskeletal US imaging has led to a widespread use of ultrasonography as a diagnostic and therapeutic technique in rheumatology. Sonography has become a powerful diagnostic and research tool in clinical rheumatology that adds valuable information simultaneously to clinical evaluation. The incorporation of ultrasound to rheumatology has been a logical extension of its e (mas) stablished practice in other specialities such as obstetrics, gynaecology and cardiology. High resolution musculoskeletal ultrasonography is a valid and reliable method for assess-ing periarticular and intraarticular anatomic structures involved in rheumatic disease. Ultrasonography has considerable advantages over other imaging modalities including non invasiveness, speed of performance, relative low cost, ability to scan multiple joints, repeatability and high patient acceptability. Musculoskeletal dynamic examina-tion in real time can be performed routinely, which shows the movement of tendons and muscles and aids the detection of abnormalities. In addition, ultrasound can be used for guidance of musculoskeletal injections and biopsies. Last but not least, rheumatologists can undertake inoffice MSUS, avoiding referral to radiologists and saving time and money.

Scientific Electronic Library Online (Spanish)

80

La ultrasonografía con sondas de alta frecuencia en el estudio de la piel y la uña psoriática/ The use of high-frequency ultrasound in the study of skin and psoriatic nail

Gutiérrez, Marwin; Restrepo, Juan Pablo; Filippucci, Emilio; Grassi, Walter
2009-12-01

Resumen en español Durante los últimos años, el campo de la ultrasonografía ha tenido importantes avances tecnológicos, llegando a desarrollar equipos que producen imágenes de alta calidad con poder de resolución inferior a 0.1 mm y provistos de módulos power Doppler que permiten un detallado estudio morfológico de los tejidos blandos, inclusive la piel. El objetivo de esta viñeta pictórica es demostrar los principales hallazgos ecográficos que se verifican en pacientes con psori (mas) asis utilizando sondas de última generación y técnica power Doppler. En este estudio se tomaron imágenes de 20 pacientes con psoriasis comparándolas con la piel de 10 sujetos sanos. Los resultados muestran una evidencia pictórica de que la ultrasonografía permite un estudio detallado, sea de la uña y de la piel, en pacientes con psoriasis. Resumen en inglés Over the last few years, continuous advances have been made in the field of ultrasonography, developing equipments providing high-quality greyscale imaging with an axial resolution power less than 0.1 mm and very sensitive power Doppler technique. This fact has opened the way to detailed imaging of the superficial tissues, including the skin. This pictorial essay shows the main sonographic findings obtainable with "last generation" high-frequency transducers and power Dop (mas) pler technique in patients with psoriatic disease. Sonographic images shown were selected from an image database collected in 20 patients with definite diagnosis of psoriasis and in 10 healthy subjects. The present report provides pictorial evidence that high resolution greyscale ultrasound and power Doppler technique allow for a detailed morphostructural assessment and a sensitive blood flow evaluation at both skin and nail level in patients with psoriatic disease.

Scientific Electronic Library Online (Spanish)

81

LSPR-based nanobiosensors

Sepúlveda Martínez, Borja; Angelomé, Paula C.; Lechuga, Laura M.; Liz-Marzán, Luis M.
2009-06-01

Digital.CSIC (Spain)

82

Integrated optical transducers for (bio)chemical sensing

Domínguez, Carlos; Rodríguez, José Antonio; Lechuga, Laura M.
2003-01-01

Digital.CSIC (Spain)

83

Industrial requirements in high-power ultrasonic transducers for defoaming

Rodríguez, Germán; Acosta, Víctor M.; Pinto, Alberto; Gallego Juárez, Juan Antonio

Ponencia presentada en el XIX Congreso Internacional de Acústica (ICA2007), Madrid, 2-7 Sep 2007.-- PACS: 43.35.-c. | Airborne stepped-plate focusing transducers have shown to be an efficient tool for breaking foams. The main characteristics of such transducers are their high efficiency and power ca...

DRIVER (Spanish)

84

Industrial requirements in high-power ultrasonic transducers for defoaming

Rodríguez, Germán; Acosta Aparicio, Víctor Manuel; Pinto, Alberto; Gallego Juárez, Juan Antonio
2007-12-01

Digital.CSIC (Spain)

85

Increasing the active surface in random sparse 2D arrays

Martínez Graullera, Óscar; Martín Arguedas, Carlos J.; Octavio Manzanares, Alberto; Godoy, Gregorio; Montero de Espinosa Freijo, Francisco; Gómez-Ullate Alvear, Luis
2008-01-01

Digital.CSIC (Spain)

86

Improving ultrasonic beam characteristics from segmented annular arrays

Martínez Graullera, Óscar; Godoy, Gregorio; Gómez-Ullate Alvear, Luis
2002-09-01

Digital.CSIC (Spain)

87

Functional Inactivation of CXC Chemokine Receptor 4–mediated Responses through SOCS3 Up-regulation

Soriano, Silvia F.; Hernanz-Falcón, Patricia; Rodríguez Frade, José M.; Martín de Ana, Ana; Garzón, Ruth; Carvalho-Pinto, Carla E.; Vila-Coro, Antonio J.; Zaballos, Ángel; Balomenos, Dimitrios; Martínez-Alonso, Carlos; Mellado, Mario
2002-08-01

Digital.CSIC (Spain)

88

Forced Expression of MMP9 Rescues the Loss of Angiogenesis and Abrogates Metastasis of Pancreatic Tumors Triggered by the Absence of Host SPARC

Arnold, Shanna; Mira, Emilia; Muneer, Sabeeha; Korpanty, Grzegorz; Beck, Adam W.; Holloway, Shane E.; Mañes, Santos; Brekken, Rolf A.
2008-04-29

Digital.CSIC (Spain)

90

Experimental observation of nonlinear self-focusing in the cavitation field

Campos-Pozuelo, Cleofé; Granger, C.; Vanhille, Christian; Dubus, Bertrand
2007-12-01

Digital.CSIC (Spain)

91

Experimental evaluation of some narrow-band ultrasonic transducers as therapy applicators

González, G.; Azbaid, Abdelhalim; Leija, L.; Ramos, Antonio; Rami, X.; San Emeterio, José Luis; Moreno, E.

6 pages, 5 figures.-- PACS nrs.: 43.35, 43.38.-- Communication presented at: Forum Acusticum Sevilla 2002 (Sevilla, Spain, 16-20 Sep 2002), comprising: 3rd European Congress on Acoustics; XXXIII Spanish Congress on Acoustics (TecniAcústica 2002); European and Japanese Symposium on Acoustics; 3rd Ibe...

DRIVER (Spanish)

92

Experimental evaluation of some narrow-band ultrasonic transducers as therapy applicators

González, G.; Azbaid, Abdelhalim; Leija, Lorenzo; Ramos, Antonio; Rami, X.; San Emeterio, José Luis; Moreno, E.
2002-09-01

Digital.CSIC (Spain)

93

Estudio experimental de la vibración de composites piezoeléctricos (2-2-2)

Montero de Espinosa Freijo, Francisco; Sánchez, S.
1998-02-01

Digital.CSIC (Spain)

94

Estudio de efectos de asimetría en vibradores ultrasónicos axisimétricos

Chacón, David; Rodríguez Corral, Germán; Riera, Enrique; Gallego Juárez, Juan Antonio

8 pages, 6 figures.-- Comunicación presentada en: XXXV Congreso Español de Acústica – TecniAcústica 2004, IV Congreso Iberoamericano de Acústica, IV Congreso Ibérico de Acústica y EAA Symposium "Environmental and Architectural Acoustics" (Guimaraes, 14-17 Sep 2004). | [EN] The use of high-power ultr...

DRIVER (Spanish)

95

Estudio de efectos de asimetría en vibradores ultrasónicos axisimétricos

Chacón, David; Rodríguez Corral, Germán; Riera, Enrique; Gallego Juárez, Juan Antonio
2004-09-01

Digital.CSIC (Spain)

97

Electrochemical biosensing of pesticide residues based on affinity biocomposite platforms.

Zacco, E.; Galvé, Roger; Marco, María Pilar; Alegret, Salvador; Pividori, María Isabel
2007-03-15

Digital.CSIC (Spain)

98

Electrical and reusable device for reading microrrays

Baldi Coll, Antonio; Fernández Sánchez, César; De la Rica Quesada, Roberto; Bonilla Aguilar, Diana Lissette
2010-01-14

Digital.CSIC (Spain)

99

Electrical and reusable device for reading microarrays

Baldi Coll, Antonio; Fernández Sánchez, César; De la Rica Quesada, Roberto; Bonilla Aguilar, Diana Lissette
2010-03-15

Digital.CSIC (Spain)

100

ESTUDIO DEL MECANISMO DE FALLA DE TERRAPLENES DEBIDO A LA INFILTRACIÓN DE AGUAS LLUVIAS MEDIANTE EL MONITOREO DE PRESIONES DE POROS Y CONTENIDOS DE AGUA/ STUDY OF FAILURE MECHANISM IN EMBANKMENTS INDUCED BY RAINFALL INFILTRATION BY MONITORING PORE WATER PRESSURES AND WATER CONTENTS

GARCÍA, EDWIN; UCHIMURA, TARO
2007-07-01

Resumen en español El presente artículo muestra experimentos realizados utilizando modelos a escala para estudiar el proceso de infiltración en terraplenes sometidos a aguas lluvias. Varios modelos a escala fueron construidos usando un suelo arenoso con alto contenido de finos; para aplicar la lluvia artificial y observar el proceso de infiltración del agua se utilizó un tubo de irrigación. Para monitorear los cambios en succión ocasionados por los ciclos de humedecimiento y secado se (mas) instalaron dentro del suelo varios sensores de presión de poros, contenido de agua y de desplazamiento en diferentes puntos. El cambio de la presión de poros en el tiempo, el contenido de agua y las relaciones entre las mediciones de presión de poros y desplazamientos del suelo son presentados. Este estudio muestra que el movimiento del suelo en un talud está directamente relacionado con el contenido de agua del suelo y las presiones de poros existentes en él, sugiriendo que por medio del monitoreo de estos dos parámetros es posible predecir fallas locales inducidas por infiltración de aguas lluvias en los taludes. Resumen en inglés This paper presents experiments using scale models to study the infiltration process on embankments subjected to rainfall infiltration. Various model embankments were built using a silty sand soil; an irrigation pipe was used to applied artificial rainfall in order to observe the effect of the water infiltration. Pore water pressure, water content and displacements transducers were installed within the scale models at various locations to monitor the changes in suction ca (mas) used during cycles of wetting and drying processes. Pore water pressure histories, water content histories and relations between measurements of pore water pressures and displacements are presented. This study showed that slope movements are directly related to the soil water content and pore water pressures within the slope, suggesting that slope failure caused by rainfall infiltration could be predicted by monitoring these parameters.

Scientific Electronic Library Online (Spanish)

101

Diseño de un dispositivo para la medición de la presión de expansión en suelos arcillosos/ Design of a device for the measurement of the swelling pressure of clayey soils.

Marcial, D; Landaeta, R
2008-04-01

Resumen en español Son bien conocidos los impactos que los suelos arcillosos causan en las vías de comunicación, así como la importancia de la adecuada determinación de sus propiedades para su consideración en el diseño de las mismas. En lo que se refiere a la presión de expansión, su determinación en laboratorio mediante el método edométrico tradicional requiere una dedicación importante del personal técnico a la supervisión del ensayo, por lo que representa un alto costo en (mas) mano de obra calificada. Dada la necesidad de resolver esta situación en el Instituto de Materiales y Modelos Estructurales, se diseño un dispositivo fiable para la medición de la presión de expansión de suelos arcillosos, con mínima intervención del personal técnico. La metodología de trabajo consistió en recopilar información bibliográfica para la concepción del dispositivo experimental, en base al estudio de las ventajas y desventajas de dispositivos existentes. Por otra parte, un estudio experimental mediante ensayos edométricos sobre dos muestras de arcillas, una de alta actividad y la otra de mediana actividad compactada a diferentes densidades, y humedades muy bajas, permite ilustrar la sensibilidad de la presión de expansión a los cambios de densidad. Luego se continúa con la concepción del dispositivo, donde se considera la forma, el material, la selección  sensores de presión y las dimensiones adecuadas. Igualmente, se realiza un modelo numérico mediante el método de elementos finitos, con el objeto de optimizar el espesor de la pared y disminuir razonablemente los costos de producción. Finalmente, se propone un sistema de adquisición de datos como parte del diseño del dispositivo, el cual provee al Instituto de Materiales y Modelos Estructurales de los elementos necesarios para construir un dispositivo confiable para medir la presión de expansión con un mínimo de intervención de personal técnico, reduciendo los costos de ejecución de este tipo de pruebas. Resumen en inglés The damages caused by swelling clays to the roads and highways are well known, also the importance of an adequate characterization of these soils for design purposes. Concerning the measure of swelling pressure in the laboratory, the controlled strain oedometer method consumes a lot of time of technical staff and that represents an important cost. In order to reduce operation costs in the laboratory, a swelling pressure device that requires a minimum of supervision time w (mas) as developed. The methodological work started with a bibliographical review. Thus, the conception of the swelling pressure device was based on the advantages and disadvantages of existing devices. Elsewhere, an experimental work consisting in the characterization of two swelling clays, one of medium activity and other of high activity, permitted to point out the sensibility of the swelling pressure to variation of the dry density. To complete the design of the swelling pressure device, a series of aspects were considered such as shape, dimensions, materials and available stress transducers. Once the shape, the internal dimensions and the material were selected, a numerical model of the device was carried out by finite element techniques in order to optimize the thickness of the walls and reduce production costs. Finally, a data acquisition system is proposed as a part of the device design, completing the necessary elements to build a reliable device to measure swelling pressure with a minimum cost in terms of supervision time.

Scientific Electronic Library Online (Spanish)

102

Development of an electronic pendulum for microinclination recordings

Orejana, M.; Vieira, Ricardo; Toro y Llaca, Carmen de
1981-01-01

Digital.CSIC (Spain)

103

Design and analysis of silicon antiresonant reflecting optical waveguides for evanescent field sensor

Prieto, Francisco; Llobera, Andreu; Jiménez, David; Domínguez, Carlos; Calle Martín, Ana; Lechuga, Laura M.
2000-07-01

Digital.CSIC (Spain)

104

Desarrollo de un Sistema de Secado mediante Lecho Fluido Asistido por Ultrasonidos de Potencia

Fuente, Susana de la; Rodríguez Corral, Germán; Riera, Enrique; Gallego Juárez, Juan Antonio; Mulet Pons, Antonio

8 pages, 8 figures.-- Comunicación presentada en: XXXV Congreso Español de Acústica – TecniAcústica 2004, IV Congreso Iberoamericano de Acústica, IV Congreso Ibérico de Acústica y EAA Symposium "Environmental and Architectural Acoustics" (Guimaraes, 14-17 Sep 2004). | [EN] The application of high po...

DRIVER (Spanish)

105

Desarrollo de un Sistema de Secado mediante Lecho Fluido Asistido por Ultrasonidos de Potencia

Fuente, Susana de la; Rodríguez Corral, Germán; Riera, Enrique; Gallego Juárez, Juan Antonio; Mulet Pons, Antonio
2004-09-01

Digital.CSIC (Spain)

106

Desarrollo de sistemas acústicos para tratamiento de fluidos. Escalamiento de prototipos de laboratorio a sistema industrial

Rodríguez Corral, Germán; Campos-Pozuelo, Cleofé; Acosta Aparicio, Víctor Manuel; Gallego Juárez, Juan Antonio; Vázquez, F.
2000-10-01

Digital.CSIC (Spain)

107

Desarrollo de generadores macrosónicos para aplicaciones industriales en medios gaseosos. Rediseño numérico del elemento radiante por problemas de fatiga

Vázquez, F.; Rodríguez Corral, Germán; Gallego Juárez, Juan Antonio; Acosta Aparicio, Víctor Manuel; Campos-Pozuelo, Cleofé; Riera, Enrique; Andrés Gallego, Eduardo
2000-10-01

Digital.CSIC (Spain)

108

Dependence of the fundamental frequencies of T. E. piezoelectric transducers on intrinsic losses and external loading

San Emeterio, José Luis; Ramos, Antonio

6 pages, 3 figures.-- PACS nr.: 43.38.Fx.-- Communication presented at: Forum Acusticum Sevilla 2002 (Sevilla, Spain, 16-20 Sep 2002), comprising: 3rd European Congress on Acoustics; XXXIII Spanish Congress on Acoustics (TecniAcústica 2002); European and Japanese Symposium on Acoustics; 3rd Iberian ...

DRIVER (Spanish)

111

Comunicaciones presentadas en el IX Symposium Internacional de Mareas Terrestres, Nueva York, 1981.

Vieira, Ricardo; Torroja, J. M.; Toro y Llaca, Carmen de; Sukhwani, P. K.; Orejana, M.; Lambas, F.; Gimenez, E.
1981-01-01

Digital.CSIC (Spain)

112

Computer-assisted translation using finite-state transducers

Civera Saiz, Jorge; Cubel Barea, Elsa María; Lagarda Arroyo, Antonio Luis; Casacuberta Nolla, Francisco; Vidal Ruiz, Enrique

DRIVER (Spanish)

113

Compilation of Constraint-based Contextual Rules for Part-of-Speech Tagging into Finite State Transducers

Graña Gil, Jorge; Andrade Sánchez, Gloria; Vilares Ferro, Jesús

With the aim of removing the residuary errors made by pure stochastic disambiguation models, we put forward a hybrid system in which linguist users introduce high level contextual rules to be applied in combination with a tagger based on a Hidden Markov Model. The design of these rules is inspired i...

DRIVER (Spanish)

115

Circuital modelling in transient regime of ultrasonic transceivers for imaging and detection including non-ideal behaviours

Ruiz Toledo, Abelardo; Ramos, Antonio; San Emeterio, José Luis; Sanz Sánchez, Pedro Tomás
2007-12-01

Digital.CSIC (Spain)

116

Caracterización de un array ultrasónico de anillos segmentados

Montero de Espinosa Freijo, Francisco; Gómez-Ullate Alvear, Luis; Martínez Graullera, Óscar; Akhnak, Mostafa
2000-10-01

Digital.CSIC (Spain)

117

Capability of segmented annular arrays to generate 3-D ultrasonic imaging

Gómez-Ullate Alvear, Luis; Martínez Graullera, Óscar; Akhnak, Mostafa; Montero de Espinosa Freijo, Francisco
2002-09-01

Digital.CSIC (Spain)

119

Au/Fe/Au multilayer transducers for magneto-optic surface plasmon resonance sensing

Regatos, D.; Fariña, D.; Calle Martín, Ana; Cebollada, Alfonso; Sepúlveda Martínez, Borja; Armelles Reig, Gaspar; Lechuga, Laura M.
2010-09-01

Digital.CSIC (Spain)

121

Aplicación de sensores piezoeléctricos cerámicos a la caracterización biomecánica

Moreno Sastoque, Juan Camilo; Ceres Ruíz, Ramón; Calderón Estévez, Leopoldo; Pons Rovira, José Luis; Fernández Lozano, José Francisco; Ochoa, P.; Rocón de Lima, Eduardo
2004-05-01

Digital.CSIC (Spain)

122

Anterograde Transport and Secretion of Brain-Derived Neurotrophic Factor along Sensory Axons Promote Schwann Cell Myelination

Ng, Benjamin K.; Chen, Lian; Mandemakers, Wilhelm; Cosgaya, José Miguel; Chan, Jonah R.
2007-07-11

Digital.CSIC (Spain)

123

Analysis of bisphenol A in natural waters by means of an optical immunosensor

Rodríguez-Mozaz, Sara; López de Alda, Miren; Barceló, Damià
2005-12-06

Digital.CSIC (Spain)

124

Analysis of a time-domain method to compute ultrasonic field through interfaces

Buiochi, Flávio; Martínez Graullera, Óscar; Gómez-Ullate Alvear, Luis; Montero de Espinosa Freijo, Francisco

6 pages, 6 figures.-- PACS nr.: 43.35.Zc.-- Communication presented at: Forum Acusticum Sevilla 2002 (Sevilla, Spain, 16-20 Sep 2002), comprising: 3rd European Congress on Acoustics; XXXIII Spanish Congress on Acoustics (TecniAcústica 2002); European and Japanese Symposium on Acoustics; 3rd Iberian ...

DRIVER (Spanish)

125

Analysis of a time-domain method to compute ultrasonic field through interfaces

Buiochi, Flávio; Martínez Graullera, Óscar; Gómez-Ullate Alvear, Luis; Montero de Espinosa Freijo, Francisco
2002-09-01

Digital.CSIC (Spain)

126

Air-coupled CMUT arrays based on MUMPS

Octavio Manzanares, Alberto; Martínez Graullera, Óscar; Martín Arguedas, Carlos J.; Gómez-Ullate Alvear, Luis

Ponencia presentada en el XIX Congreso Internacional de Acústica (ICA2007), Madrid, 2-7 Sep 2007.-- PACS: 43.38.Hz. | Manufacturing capacitive micromachined ultrasonic transducers (cMUTs) is possible using several low cost standard processes. The multi-user MEMS process (MUMPS) offers this possibili...

DRIVER (Spanish)

127

Air-coupled CMUT arrays based on MUMPS

Octavio Manzanares, Alberto; Martínez Graullera, Óscar; Martín Arguedas, Carlos J.; Gómez-Ullate Alvear, Luis; Montero de Espinosa Freijo, Francisco
2007-12-01

Digital.CSIC (Spain)