Sample records for TENDONES (tendons)
from WorldWideScience.org

Sample records 1 - 18 shown.



1

Anomalous extensor tendons of hand: a case report with clinical importance/ Tendones anómalos del extensor de la mano y su importancia clínica

Paul, Shipra; Das, Srijit
2007-03-01

Resumen en español El músculo extensor de los dedos de la mano se origina a partir del comienzo del extensor común, es decir, del epicóndilo lateral del húmero y termina en cuatro tendones, uno para cada dedo, excepto el pulgar. Este trabajo informa un caso donde el tendón del extensor de los dedos terminaba como cuatro tendones para los dedos índice, medio, anular y meñique, pero mostraba variaciones en el número de tendones para cada dedo. En efecto, se observaron dos tendones en (mas) los dedos anular y meñique. Tal disposición de los tendones del extensor de los dedos puede tener importancia clínica. La presencia de tendones múltiples puede también alterar la cinética alrededor del sitio de inserción a la falange. El conocimiento de la anatomía normal y anormal de los tendones extensores es de utilidad cuando se hacen cirugías como transferencia de tendones e injertos. Resumen en inglés The extensor digitorum muscle of the hand originates from the common extensor origin i.e., from the lateral epicondyle of the humerus and ends in four tendons, one for each digit except for the thumb. This paper reports a case, in which the tendon of the extensor digitorum ended as four tendons to the index, middle, ring and little fingers, but displayed variations in the number of tendons to each finger. Two tendons of extensor digitorum were observed in the ring and the (mas) little finger. Such an arrangement of the tendons of the extensor digitorum may have clinical importance. The presence of multiple tendons may also alter the kinematics around the site of attachment to the phalanx. Knowledge of abnormal and normal anatomy of the extensor tendons, may be helpful while performing graft and tendon transfer operations.

Scientific Electronic Library Online (Spanish)

2

ESTUDIO ANATÓMICO DE LAS INSERCIONES DE LOS MÚSCULOS EXTENSORES RADIALES LARGO Y CORTO DEL CARPO/ ANATOMICAL STUDY OF INSERTIONS OF THE EXTENSOR CARPI RADIALIS LONGUS AND BREVIS

Ferreira Caetano, Mauricio; Manna Albertoni, Walter; Benedito Caetano, Edie; Montaño Pérez, Rodrigo
2004-12-01

Resumen en español En el análisis de los tendones de los músculos extensores radiales largo y corto del carpo, basados en la disección anatómica de 60 miembros superiores de cadáveres adultos de raza blanca y sexo masculino, registramos que las variaciones anatómicas no son muy frecuentes. La presencia de tendones accesorios ocurrió en apenas 3 manos disecadas, todas del músculo extensor radial largo del carpo. La presencia de vínculos tendinosos uniendo los tendones, fue registrad (mas) a en 17 piezas. La presencia de un tendón intermedio uniendo los dos tendones, fue verificada en 4 piezas. La inserción del tendón del músculo extensor radial largo del carpo ocurrió, invariablemente, en el lado radial de la base del segundo metacarpiano y del músculo extensor radial corto en el lado radial de la base del tercer metacarpiano. Basados en nuestras disecciones podemos afirmar que la conformación anatómica normal de los músculos extensores radiales largo y corto del carpo, es la presencia de un cuerpo muscular y un tendón de cada uno de los músculos extensores radiales que son cubiertos por los músculos abdutor largo y extensor corto; pasan por el segundo compartimiento dorsal del puño y se insertan, el músculo extensor radial largo en el lado radial de la base del segundo metacarpiano y el músculo extensor radial corto en el lado radial de la base del tercer metacarpiano, invariablemente Resumen en inglés The aim of this paper was to analyse the anatomical variations of the extensor carpi radialis longusand brevis in sixty male adults cadaver upper limbs. The extensor carpi radialis longus and brevis muscles and tendons had a few anatomical variations, but very important about surgical aspects. The supernumerary tendons were found in 3 hands (all in relation to the extensor carpi radialis longus tendon). The presence of tendinous connections between the two tendons was fou (mas) nd in 17 upper limbs. The presence of an accessory tendon making the union between the tendons of extensor carpi radialis brevis and longus was registered in 4 dissected hands. The insertion of the extensor carpi radialis longus tendon was in the radial side of the base of second metacarpal bone and the extensor carpi radialis brevis in the radial side of the base of third metacarpal bone in all dissected hands. The more common pattern of the extensor carpi radialis longus and brevis was one muscle and one tendon of the extensor carpi radialis longus and brevis, localized in the second dorsal wrist compartment, and with a constant insertion in the radial side of bases of the second and third metacarpal bones

Scientific Electronic Library Online (Spanish)

3

Movilización activa y control farmacológico en los injertos de los flexores de la mano/ Active mobilization and pharmacological control in the grafts of the hand flexors/ Mobilisation active et contrôle pharmacologique dans les greffes des fléchisseurs de la main

MONREAL GONZÁLEZ, RICARDO; MONREAL ACOSTA, PEDRO; GÓMEZ HERNÁNDEZ, DAMIÁN; DÍAZ QUESADA, JUAN M.
1997-12-01

Resumen en español Se exponen los resultados obtenidos en el tratamiento de lesiones de los tendones flexores de la mano ocurridas en la zona II en 7 pacientes (10 dedos) empleando la movilización precoz activa y el control farmacológico de la respuesta inflamatoria y de las adherencias tendinosas con alopurinol. Se obtuvo resultados satisfactorios en 9 dedos. Resumen en inglés The results obtained in the treatment of injuries of the flexor tendons of the hand occurred in zone II in 7 patients (10 fingers) by using the early active mobilization and the pharmacological control of the inflammatory response and of the tendinous adherences with allopurinol are shown. Satisfactory results were obtained in 9 fingers.

Scientific Electronic Library Online (Spanish)

4

MÚSCULOS FLEXORES ACCESORIOS DEL IV Y V DEDOS DEL PIE: VARIACIÓN ANATÓMICA/ FLEXOR ACCESSORIUS MUSCLES TO THE IV AND V FINGERS OF THE FOOT: ANATOMICAL VARIATION

Torrez, Juan Carlos; del Sol, Mariano
2002-01-01

Resumen en español Los músculos supernumerarios intrínsecos del pie, no son frecuentemente nombrados en los textos de anatomía a pesar que ellos pueden eventualmente producir alteraciones en la mecánica articular. Describimos la presencia de dos músculos supernumerarios encontrados en un pie de un cadáver formolizado, de sexo masculino, adulto, disecado en el Curso de Anatomía Funcional del Pie, perteneciente al Programa de Magíster en Ciencias, Mención Morfología de la Universida (mas) d de La Frontera, Chile. Los músculos supernumerarios destinados al IV y V dedo: inferomedial y superolateral, respectivamente, presentaban vientres musculares cortos y tendones de inserción largos, relacionándose ambos en su origen con el nervio plantar medial. Parte de su vientre y de sus tendones se ubicaban entre los músculos cuadrado plantar y flexor corto de los dedos. Estos músculos son similares a algunos relatos de la literatura, sin embargo creemos que su incidencia es relativamente baja en individuos chilenos Resumen en inglés The supernumerary intrinsic muscles of the toe are not frequently mentioned in anatomy texts, although they may eventually produce alterations in the articulated mechanics. We described the presence of two supernumeraries found in a formolized adult dissected male corpse in the Toe Functional Anatomy Course, belonging to the Ms. Sc. in Morphology of the Universidad de La Frontera, Chile. The supernumerary muscle for the 4th and 5th fingers: inferomedial and superolateral, (mas) respectively, presented short muscular belly and tendons of long insertion, relating both in their origin eith the medial plantar nerve. Part of their belly and tendons were located between the flexor digiti minimi muscle and the quadratus plantae muscle. These muscles are similar to some reports of the literature; however, we think their incidence is relatively low in Chilean individuals

Scientific Electronic Library Online (Spanish)

5

Nueva técnica para restablecer la oponencia del pulgar

Alfonso Muñoz, Santiago; Pérez Capdet, Pablo
2002-03-01

Resumen en español Se presenta una nueva técnica quirúrgica para restablecer la oponencia del pulgar en pacientes con síndrome compresivo del túnel del carpo y parálisis de la rama motora del nervio mediano. Se seleccionaron de forma intencionada 10 pacientes con una edad promedio de 53 años, durante el período comprendido de septiembre de 1999 a abril del 2000, con el diagnóstico de síndrome compresivo del túnel del carpo y parálisis de la rama motora del nervio mediano para la (mas) región tenar, a los cuales se les realizaron los procederes siguientes: apertura del ligamento transverso volar del carpo, neurólisis externa del nervio mediano, sinovectomía, tenólisis de los tendones flexores, nueva técnica para restablecer la oponencia del pulgar. De la serie tratada (10 casos), 4 fueron evaluados de excelentes (40 %), 5 de buenos (50 %), 1 regular (10 %) según los criterios de evaluación de Sundararaj y Mani de 1984. Esta nueva técnica quirúrgica para restablecer la oponencia del pulgar, dio como resultados que el 90 % de los casos fueron evaluados de satisfactorio. Resumen en inglés A new surgical technique is presented to reestablish the opposition of the thumb in patients with carpal tunnel syndrome and paralysis of the motor branch of the median nerve. From September, 1999, to April, 2000, 10 patients with an average age of 53 years old and with a diagnosis of carpal tunnel syndrome and paralysis of the motor branch of the median nerve for the thenar region, were intentionally selected. They underwent the following procedures: opening of the volar (mas) transverse ligament of the carpus, external neurolysis of the median nerve, synovectomy, tenolysis of the flexor tendons, and a new technique to reestablish the thumb opposition of the thumb. Of the treated series (10 cases), 4 were evaluated as excellent (40 %), 5 as good (50 %), and 1 as fair (10 %), according to the evaluation criteria of Sundararaj and Mani, from 1984. This new surgical technique to reestablish the opposition of the thumb made possible that 90 % of the cases were evaluated as satisfactory.

Scientific Electronic Library Online (Spanish)

6

Características Anatómicas del Tendón Extensor Accesorio del Dedo Anular, Procedente del Músculo Extensor del Dedo Mínimo/ Anatomical Characteristics of the Accessory Extensor Tendon of the Ring Finger, Originating from the Extensor digiti minimi Muscle

de Mendonça, Rodas, P. M; Rocha, A. C; Buarque de, Gusmão, L; Sousa-Rodrigues, C. F; Olave, E
2006-09-01

Resumen en español El músculo extensor del dedo mínimo es una larga y estrecha lámina muscular que se origina en el epicóndilo lateral del húmero, en el tendón extensor común, insertándose, generalmente, a través de dos cintillas tendinosas, en la expansión extensora del dedo mínimo. A veces, emite un tendón accesorio para el dedo anular.El objetivo del presente estudio fue conocer la incidencia, disposición y trayecto de este tendón accesorio. Se estudiaron 60 piezas de miemb (mas) ros superiores, fijadas en formaldehído al 10 %, correspondientes a cadáveres de individuos brasileños, adultos, de ambos sexos. El tendón accesorio fue encontrado en 7 manos (11,7% de los casos). La presencia de ese tendón tiene importancia funcional y clínico-quirúrgica, pues en casos de lesiones en el dorso de la mano que afecten a los tendones del músculo extensor de los dedos, este tendón accesorio podría establecerse como una forma alternativa en la recuperación del movimiento de la extensión del dedo anular. Los resultados complementarán el conocimiento anatómico del conjunto de tendones que constituyen el dorso de la mano Resumen en inglés The extensor digiti minimi muscle originates from the posterior aspect of the lateral epicondyle of the humerus from a common tendon for the epicondilar muscles. The muscular belly is long and narrow and runs distally until it joins the ulnar side of a tendon over the radiocarpal articulation. Over the dorsum of the hand, this muscle is represented by a double tendon that insert in the extensor apparatus. Sometimes, these tendons give off an accessory tendon for the ring (mas) finger. The objective of this present study was to know the incidence, disposition and course of this accessory tendon. We are study 60 upper limbs from Brazilian adult cadavers of both sexs, fixed in formaldehyde 10%. The accessory tendon of the ring finger was found in 7 hands (11,7% of the cases). The presence of this tendon have functional and surgical importance; in extensor digitorum tendons injuries, this accessory tendon could be an alternative for recuperate the extension movement of the ring finger. Our results will complete the anatomic knowledge over the dorsal tendons of the hand

Scientific Electronic Library Online (Spanish)

7

HIPOPLASIA DEL PULGAR: PRESENTACIÓN CLÍNICA Y RECONSTRUCCIÓN/ Hipoplasia of the thumb: Clinical presentation and reconstruction

Vergara Amador, Enrique M
2008-03-01

Resumen en español Antecedentes. En la génesis de la ausencia parcial o total del pulgar se encuentran factores genéticos, ambientales o una combinación de ambos. Puede hacer parte de un síndrome o encontrarse aisladamente y frecuentemente asociada con problemas de deficiencia longitudinal radial del antebrazo. Objetivo. El propósito de este estudio es mostar la experiencia, el enfoque del tratamiento y los resultados obtenidos desde el punto vista funcional y estético. Material y mé (mas) todos. Es un trabajo observacional descriptivo tipo serie de casos en 22 niños operados con hipoplasia del pulgar y con un seguimiento mínimo de 12 meses (promedio 28 meses). En 15 casos había asociación de displasia radial u otra anomalía entre ellos cuatro pacientes con VATER, y los siete restantes correspondían a hipoplasia del pulgar como única entidad. Se realizó transferencia tendinosa, con apertura de la primera comisura en dos pacientes con hipoplasia tipo II. En tres pacientes, con hipoplasia tipo III A, se realizó apertura de comisura, transferencia del flexor superficial del cuarto dedo para corregir inestabilidad de la articulación MF y oposición del pulgar, y transferencia para extensión del pulgar. En 17 casos se realizó pulgarización del índice. Resultados. Se evaluó la pinza en: no pinzamiento, pinzamiento lateral y pinzamiento de pulpejos; el grado de oposición como buena, leve y no oposición, y el resultado estético según la satisfacción de los padres en malo, regular y bueno. Los cinco niños reconstruidos con transferencias de tendones y apertura de comisura tuvieron buen resultado. En 17 niños con pulgarización tuvimos una necrosis, de los 16 restantes se obtuvo un buen o aceptable resultado. Discusión. No es fácil seguir un buen sistema de medición de los resultados funcionales. Se encontró que una manera práctica de evaluar fueron la pinza, oposición y estética. Previo a las cirugías se requiere descartar alteraciones hematológicas o renales. Pacientes con deficiencia longitudinal del radio tienen peores resultados que los pacientes que tuvieron hipoplasia única del pulgar. En general los resultados fueron buenos y están de acuerdo con los reportes de la literatura donde escriben que el procedimiento ideal para la reconstrucción de un pulgar hipoplásico tipo IIIb, IV y V sigue siendo la pulgarización. Resumen en inglés Background. in the genesis of the partial or total absence of the thumb they are genetic, environmental factors or a combination of both. It is take part of a syndrome or to be isolated and frequently associated with problems of radial longitudinal deficiency of the forearm. Objective. The purpose of this study is mostar the experience, the focus of the processing and the results obtained since the point esthetic and functional view. The most it accepted classification is (mas) the proposal by Blauth that helps to determine the forecast and the processing. Materials and methods. it is a work type series of cases in 22 children with hipoplasia of the thumb, with a minimum of 12 months, (average 28 months). In 15 cases there were association of radial dysplasia or another anomaly among them 4 patients with VATER, and the 7 remaining they corresponded to hipoplasia of the thumb as only entity. We carried out tendon transfer, with opening of the first comisure in 2 patients with hipoplasia type II. In 3 patients, with hipoplasia type III A, one carries out corner opening, transfer of the superficial flexor of the 4 finger to correct instability of the articulation MF and opposition of the thumb, and transfer for extension of the thumb. In 17 cases one carries out pollicization of the index. Results. The outcome was evaluated in: non pinch, lateral pinch and fingertip pinch; the grade of opposition like good, minimal and non opposition, and the aesthetic result according to the satisfaction of the parents in bad, regular and good. The five children reconstructed with transfers of tendons and comisure opening had good result. In 17 children with pollicization one patient had a necrosis, of the 16 remaining a good or acceptable result was obtained. Discussion. It is not easy to follow a good system of measure of the functional results. We find that a practical way to evaluate was the clip, opposition and aesthetics. Previous to the surgeries it is required to evaluate alterations hematological or renal. Patient with longitudinal deficiency of the radius they have worse results that the patients that had unique hypoplastic thumb. In general the results were good and they agree with the reports of the literature where they write that the ideal procedure for the reconstruction of the hypoplastic thumb type IIIb, IV and V continue being the pulgarización.

Scientific Electronic Library Online (Spanish)

8

ASPECTOS ANATÓMICOS Y BIOMÉTRICOS DE LA ARTERIA DORSAL DEL PIE EN HUMANOS/ ANATOMICAL AND BIOMETRIC ASPECTS OF THE DORSALIS PEDIS ARTERY IN HUMANS

Gabrielli, Carla; Braga, Maria Terezinha Teixeira; Olave, Enrique; Froehner Jr, Ilário; Rodrigues, Igor Kunze
2001-12-01

Resumen en español Los pies son partes importantes del cuerpo que están relacionados con descarga del peso, postura bípeda, locomoción y equilibrio. Con el propósito de evitar amputaciones, han sido frecuentes las tentativas de su revascularización a través de puentes arteriales. Debido a que la arteria dorsal del pie (AD) es utilizada como receptora de flujo, fueron estudiadas sus características anatómicas y biométricas. Se utilizaron 30 pies de 15 cadáveres de individuos brasil (mas) eños adultos, de ambos sexos, en su mayoría blancos, pertenecientes al Departamento de Ciencias Morfológicas de la Universidade Federal de Santa Catarina. Las arterias fueron inyectadas con látex neoprene (Artifix L-14) teñido de rojo, disecando el dorso del pie bajo lupa. La AD estuvo presente en 100%; el calibre promedio en su origen fue de 3,16 ± 0,67 mm y a nivel de su terminación de 2,19 ± 0,71 mm. Su longitud promedio fue de 78, 32 ± 13,58 mm. En el 90% de los casos la AD se localizó entre los tendones de los músculos extensores largos del hálux y de los dedos. Su relación con el ramo cutáneo del nervio fibular profundo fue variable, en el 33,3% el ramo fue medial; en el 13,3% el ramo fue lateral y en el 26,7% el ramo cruzó a la arteria, generalmente de medial hacia lateral. En el 10% el ramo no presentó relación con la AD, ya que fue reemplazado por ramos del nervio fibular superficial. En el 16,7% restante fueron observados otros padrones de relación, como la sobreposición del ramo a la arteria. En relación a las ramas colaterales de la AD, dos fue el número más frecuente de arterias tarsales mediales (56,6%), así como también el de las arterias tarsales laterales (60%); la arteria arqueada estuvo presente sólo en 26,7%. La AD tiene características anatómicas compatibles con la realización de puentes arteriales, pero se debe tener cuidado en aquellos casos donde el nervio cruza o se sobrepone a la arteria, para evitar su lesión durante procedimientos quirúrgicos Resumen en inglés The feet are important in the weight support, biped posture, locomotion and equilibrium. The attempts of its revascularization are frequent, through the arterial bypasses, with the purpose of avoid amputations. Due to the dorsalis pedis artery (DP) is used as flow receptor vessel, we study its anatomical and biometrics characteristics. We used (utilized) 30 feet from 15 Brazilian adult cadavers, of both sexes, from the Department of Morphological Sciences of the Universid (mas) ade Federal de Santa Catarina, Brazil. The arteries were injected with neoprene latex (Artifix L14) stained red and the dorsum of foot was dissected under magnification. The DP was present in 100%; the average diameter in its origin was 3.16 ± 0.67 mm and at level of its termination was 2.19 ± 0.71 mm. The DP length was 78.32 ± 13.58 mm. The DP placed between the extensor hallucis longus and extensor digitorum longus tendons in 90% of the cases. Its relationship with the cutaneous branch of the deep fibular nerve was variable: the branch was medial to DP in 33.3%; it was lateral in 13.3% and it crossed superiorly the artery (usually from medial to lateral) in 26.7%. The branch did not related with the DP in 10%, because it was replaced by endings of the superficial fibular nerve. In the remaining 16.7% we observed other relationship patterns, as the overlaying of the branch on the DP. In respect to the DP collateral branches, the most frequent number of medial tarsal arteries was two (56.6%), equal to the lateral tarsal arteries (60%); the arcuate artery was present in only 26.7%. The DP has compatible anatomical characteristics with the arterial bypasses construction, but it must have care in those cases which the nerve crosses the artery or superposes it, to avoid its lesion during of surgical procedures

Scientific Electronic Library Online (Spanish)

9

La ultrasonografía en reumatología: un antes y un después/ Before and after sonography is applied in rheumatology

Naredo Sánchez, Esperanza
2007-06-01

Resumen en español La ultrasonografía es una técnica diagnóstica y terapéutica de relativamente reciente introducción en reumatología, en vertiginoso desarrollo tecnológico y en pleno auge en cuanto a aplicación clínica e investigación. Su empleo ha sido posterior al de otras especialidades porque los medios técnicos necesarios para obtener imágenes de suficiente calidad del aparato locomotor comenzaron a desarrollarse a finales de los años 80, con la fabricación de las sondas (mas) lineales de alta frecuencia-alta resolución actualmente disponibles. Con la ecografía la deducción diagnóstica clásica se ha hecho más profunda porque esta técnica nos permite ver lo que está ocurriendo debajo de la piel, en los tendones, músculos y articulaciones, sin dañar al paciente. Por ello, es una herramienta idónea en la práctica diaria del reumatólogo ya que se convierte en una extensión de la exploración física en lugar de una exploración complementaria convencional más. La ecografía es una técnica válida y fiable para el estudio de las estructuras periarticulares e intraarticulares implicadas en las enfermedades reumatológicas. Es relativamente económica, inocua, rápida, repetible, dinámica y bien aceptada por el paciente. Se realiza en tiempo real en la misma consulta, permitiendo una correlación inmediata entre los datos clínicos y las imagenes del paciente. Finalmente, una aplicación esencial es la ecografía intervencionista, en la que podemos guiar las punciones diagnósticas y/o terapéuticas del aparato locomotor mediante la visualización del trayecto de las agujas de punción en la pantalla, con lo que conseguimos el alcance preciso y seguro de la lesión. Resumen en inglés Within the last 20 years, the development of high frequency transducers, which have greatly improved musculoskeletal US imaging has led to a widespread use of ultrasonography as a diagnostic and therapeutic technique in rheumatology. Sonography has become a powerful diagnostic and research tool in clinical rheumatology that adds valuable information simultaneously to clinical evaluation. The incorporation of ultrasound to rheumatology has been a logical extension of its e (mas) stablished practice in other specialities such as obstetrics, gynaecology and cardiology. High resolution musculoskeletal ultrasonography is a valid and reliable method for assess-ing periarticular and intraarticular anatomic structures involved in rheumatic disease. Ultrasonography has considerable advantages over other imaging modalities including non invasiveness, speed of performance, relative low cost, ability to scan multiple joints, repeatability and high patient acceptability. Musculoskeletal dynamic examina-tion in real time can be performed routinely, which shows the movement of tendons and muscles and aids the detection of abnormalities. In addition, ultrasound can be used for guidance of musculoskeletal injections and biopsies. Last but not least, rheumatologists can undertake inoffice MSUS, avoiding referral to radiologists and saving time and money.

Scientific Electronic Library Online (Spanish)

10

Cambios Morfológicos en la Regeneración del Tendón Calcáneo de Rata (Sprague Dawley) por la Aplicación de Ultrasonido Continuo/ Morphologic Changes of the Regeneration in the Rat's (Sprague Dawley) Calnaeous Tendon by Continous Ultrasound Applications

Schencke, Carolina; del Sol, Mariano
2010-06-01

Resumen en español Las lesiones de los tendones plantean siempre grandes problemas clínicos y terapéuticos, por su importancia funcional y su peculiar cicatrización. El apoyo fisiátrico, específicamente el tratamiento con ultrasonido, ha demostrado ser eficiente en la regeneración del tendón calcáneo. Este trabajo tuvo como objetivo analizar morfológicamente los efectos del uso de ultrasonido continuo en la regeneración post quirúrgica del tendón calcáneo de rata. Se utilizaron (mas) 15 ratas albinas, Sprager Dawle. Luego de 48 horas post tenorrafia se comenzó con una sesión diaria de ultrasonido terapéutico con una intensidad de 1W/cm², frecuencia de 3 MHZ, cabezal de 0,5 cm de ERA, por 30 segundos durante 10 días. Las ratas fueron sacrificadas 48 horas después de terminar las aplicaciones de ultrasonido para la extracción y disección del tendón calcáneo del miembro posterior derecho, mientras que el tendón del miembro posterior izquierdo sirvió de control normal. Para fines de comparación morfológica se trabajó con un grupo de ratas control del tratamiento, en el que se provocó la lesión sin aplicar ultrasonido. Las muestras fueron fijadas en formalina tamponada y teñidas con H.E. Los tendones del grupo experimental se encontraron en un estado de regeneración avanzada, cuyos fibroblastos presentaron características morfológicas propias de una célula activa en la síntesis y secreción de matriz extracelular, con un promedio de fibroblastos similar al obtenido en el tendón normal. A su vez, el tendón del grupo sin tratamiento presentó un estado de regeneración tardío. Las fibras colágenas estaban invadidas por tejido conjuntivo y vasos sanguíneos, con un promedio de fibroblastos que triplica al promedio encontrado en el control normal, lo que determinó que el tendón sin aplicación de ultrasonido se encontrara aún en proceso inflamatorio. Este estudio confirma que el uso de ultrasonido continuo genera una rápida proliferación celular en el tendón lesionado de rata, y en consecuencia, acelera su regeneración Resumen en inglés Tendon injuries always account for major clinical and therapeutic problems, due to their functionalsignificance and unique healing. Physiatrics support, specifically ultrasound treatment, has been shown to be effective in the regeneration of the calcaneal tendon.The objective of this study was to morphologically analyze the effect of the use of continuous ultrasound in the post surgery regeneration of the calcaneal tendon of the rat.Ten albino, Sprager Dawley rats were us (mas) ed. Following 48 hours of post tenorrhaphy, a daily session of therapeutic ultrasound was initiated, with an intensity of 1W/cm², frequency of 3 MHZ, header at 0.5 cm ERA, per 30 seconds for 10 days. The rats were sacrificed 48 hours after completion of the ultrasound treatments, for the extraction and dissection of the calcaneal tendon of the right posterior member, while the left posterior member was used for normal control. For purposes of morphological comparison a group of control rats for the treatment was used, in which the injury was caused without applying the ultrasound.Samples were fixed in buffered formalin and stained with H.E. The tendons of the experimental group were found to be in an advanced stage of regeneration which fibroblasts presented morphological characteristics of an active cell in the synthesis and secretion of the extracellular matrix, with an average of fibroblasts similar to that obtained in the normal tendon. At the same time, the tendon of the control group in the treatment, presented a later regeneration stage. The collagen fibers were infiltrated by conjunctive tissue and blood vessels, with an average of fibroblasts that tripled the average found in the normal control, which determined that the tendon without the ultrasound treatment was still in an inflammatory process. This study confirms that the use of continuous ultrasound generated a rapid cellular proliferation in the injured tendon of the rat, and consequently accelerates its regeneration

Scientific Electronic Library Online (Spanish)

11

Lesiones tendinosas del tobillo en resonancia magnética: análisis retrospectivo en 548 estudios/ Tendinous lesions of the ankle in MRI: retrospective review in 548 exams

Cabrini, Marcelo F.; Docampo, Jorge R.; Nápoli, Augusto; Battezzati, Paola; Martino, Darío C.; Bruno, Claudio H.
2009-03-01

Resumen en español Objetivo: Determinar la prevalencia de las diversas lesiones tendinosas del tobillo y sus características iconográficas típicas en los pacientes sometidos a Resonancia Magnética (RM). Material y métodos: Se efectuó un análisis descriptivo, retrospectivo y de corte transversal, de 548 estudios de RM de tobillo durante un período de 18 meses (entre enero de 2006 y junio de 2007), que contabiliza el total de los exámenes obtenidos en resonadores de campo cerrado en (mas) Diagnóstico por Imágenes Adrogué y en las sedes Hospital Fiorito de Avellaneda y Fundación Científica del Sur. Resultados: Del total de exámenes (n=548), el 40.3% fueron realizados a pacientes de sexo femenino (n=221) y el 59.7% a pacientes de sexo masculino (n=327), con una edad promedio de 47.6 ± 17 años. El 60.5% de los estudios (n=331) no reveló alteraciones en ningún grupo tendinoso del tobillo, mientras que el 39.5% (n=217) demostró la presencia de algún tipo de patología tendinosa. Asimismo, 64 estudios (11.7%) revelaron alteraciones en el tendón tibial posterior; 47 (8.6%) en el tendón de Aquiles; 34 (6.2%) en el tendón peroneo lateral corto; 27 (4.9%) a nivel del tendón del flexor propio del hallux; 26 (4.7%) en el tendón peroneo lateral largo; 10 (1.8%) en el tendón flexor común de los dedos; 6 (1.1%) en el tendón tibial anterior; y 3 (0.5%) en el tendón extensor común de los dedos. Conclusiones: La RM constituye una excelente herramienta en la valoración de las diversas patologías tendinosas debido a su capacidad multiplanar y a su alto contraste tisular. Resumen en inglés Purpose: To determine the prevalence of several tendinous lesions of the ankle, and the MR imaging features that characterize these lesions. Materials and methods: MR images in 548 exams of ankle were retrospectively reviewed. These studies were performed during a 18-months period of time in 3 MR scanners at Hospital Fiorito (Avellaneda), Diagnóstico por Imágenes Adrogué, and Fundación Científica del Sur Avellaneda. Results: The ankle MR images (n=548) were taken fro (mas) m 221 women, and 327 men; median age, 47.6 years. In 60.5% studies (n=331), no pathologic images were identified. Sixty four exams (11.7%) showed some kind of tendon injury in the tibialis posterior tendon, 47 (8.6%) in the Achilles tendon, 34 (6.2%) in the peroneus brevis tendon, 27 (4.9%) in the flexor hallucis longus tendon, and 26 (4.7%) in the peroneus longus tendon. Additional findings included lesions in the flexor digitorum longus tendons (n=10), in the tibialis anterior tendon (n=6), and in the extensor digitorum longus tendons (n=3). Conclusions: The high-quality soft-tissue contrast resolution, noninvasive nature, and multiplanar capabilities of the MR images make it an excellent tool for the detection and evaluation of a variety of tendon disorders in the ankle.

Scientific Electronic Library Online (Spanish)

12

Tenosinovitis flexora piógena de la mano: hallazgos ecográficos/ Pyogenic flexor tenosynovitis of the hand: sonographic findings

Rodríguez, A.; Pérez-Fontán, F. J.; Fernández, P.; Álvarez, A.; Midón, J.; Martelo, F.
2007-09-01

Resumen en español Los autores describen los hallazgos ecográficos en tres pacientes con tenosinovitis flexora piógena (TFP) de la mano. Los hallazgos patológicos encontrados en el Eco-Doppler Color fueron un halo hipoecogénico peritendinoso y una hipervascularización de la vaina sinovial. La Ecografía es un procedimiento no invasivo que permite diagnosticar de manera eficiente y precoz la TFP y permite además realizar un estadiaje preoperatorio siendo una guía útil para planificar (mas) la cirugía en función de la cantidad y localización de la colección purulenta y de la integridad tendinosa. Resumen en inglés The authours describe the sonographic findings in three cases of pyogenic flexor tenosynovitis of the hand. Hipoechogenic peritendinous area and hipervascularization of the synovial sheath revealed as the pathologic findings. In Color Doppler US Ultrasound is a non-invasive procedure that allows to make an accurate and early diagnosis of pyogenic flexor tenosynovitis, it is an useful guide for planning surgery taking account the amount and localization of the purulence and the integrity of the tendons.

Scientific Electronic Library Online (Spanish)

13

Músculo Elevador de la Escápula: Caracterización Macroscópica/ Levator Scapulae Muscle: Macroscopic Characterization

Mardones Valdivieso, Felipe; Rodríguez Torres, Alberto
2006-06-01

Resumen en español Nuevas técnicas y aplicaciones quirúrgicas han impulsado un mayor estudio anatómico del músculo elevador de la escápula. Sin embargo, persisten interrogantes sobre su morfología, las que son de importancia al considerarlo como una herramienta reconstructiva. Se trabajó con 11 cadáveres (ocho masculinos y tres femeninos) con edad promedio de 70 años. Se realizó una disección bilateral por planos de las regiones cervical y escapular en 9 preparados, en 2 casos fu (mas) e unilateral. Fueron analizadas variables macroscópicas como: conformación general, ubicación, origen e inserción, relaciones directas y variaciones. Ubicado en las regiones cervicales posterior y lateral, y escapular, su forma asemeja una cincha, conformado por fascículos musculares hacia su origen y una masa muscular común en su inserción. Observamos un promedio de fascículos por músculo de 3.95 (D.E. ±0.85), con longitudes totales entre 18.3 cm como máximo y 14.9 cm como mínimo. Los fascículos se originaron mediante elementos tendinosos, en promedio 3.9 (D.E. ±0.78), desde las primeras vértebras cervicales. Se comprobó la inserción muscular directa en varios puntos a nivel de la escápula y fascia del músculo serrato anterior. Destacamos además, la presencia de un desdoblamiento de la masa muscular común previo a su inserción escapular. Fueron identificadas, además, relaciones directas con elementos musculares, vasculares, nerviosos y linfáticos en las regiones estudiadas. Finalmente, encontramos variaciones respecto al origen de los fascículos, trayecto de las fibras musculares e inserción. La anatomía del desarrollo del músculo ayuda a entender y explicar varias de las observaciones macroscópicas. Si bien algunas de las características morfológicas (relaciones directas y variaciones) desincentivan su uso, otras (longitud de los fascículos musculares y ubicación topográfica) lo señalan como una buena alternativa en la cirugía reconstructiva de cabeza y cuello Resumen en inglés Recent surgical techniques and applications have prompted a thorough anatomical study of the levator scapulae muscle. However, there are still questions regarding its morphology which are important to consider if it is to be used as a reconstructive tool. In this study, 11 human corpses were used (8 males and 3 females), with an average age of 70 years. We dissected in a step-wise manner both sides of 9 cervical and scapular regions, and in 2 cases, only one side. Differe (mas) nt macroscopic features were analyzed such as: configuration, location, muscle origins and insertions, direct relationships and variations. The muscle was located in the posterior and lateral cervical as well as scapular regions. It resembles a cinch, as it originates from various muscular fascicles and inserts as a common muscular mass. We observed an average of 3.95 (S.D ±0.85) fascicles per muscle, with total lengths in the range between 14.9 c.m. to 18.3 c.m. The fascicles originated from tendons from the cervical vertebrae, with an average of 3.9 (S.D ±0.78) per muscle. Distally, the muscle inserted in various points of the scapulae, as well as the fasciae of the serratus anterior muscle. Just before its insertion, we also observed the splitting of the muscle into 2 flaps. Several vascular, nervous, muscular and lymphatic elements in the cervical and scapular regions were closely related to the levator scapulae muscle. Also, anatomical variations were observed regarding the muscle´s origins, muscle fibers and insertions. The developmental events of the muscle are useful to understand some of the macroscopic observations. Although some of its morphologic features discourage its use (close relationships, variations), others (length of fascicles and location) enlight it as a good alternative in the reconstructive surgery of the head and neck

Scientific Electronic Library Online (Spanish)

14

Xantomatosis cerebrotendínea: Una causa de aumento de volumen bilateral del tendón de Aquiles. Caso clínico/ Cerebrotendinous xanthomatosis: Report of one case

Filippi N, Jorge; Irarrázaval D, Sebastián; Peredo O, Pilar; Mellado T, Patricio
2009-06-01

Resumen en inglés Cerebrotendinous xanthomatosis is an inherited autosomal recessive disease caused by a mutation in the gene for the sterol 27-hydroxylase enzyme, which determines the accumulation of plasmatic cholestanol in various tissues. The natural history of this disease is characterized by chronic diarrhea beginning in childhood, cataract in youth, tendinous xanthomas in adulthood and later progressive neurological dysfunction manifested as dementia, psychiatric disorders, cerebell (mas) ar, pyramidal or extra pyramidal signs or seizures. We report a 39 year-old male with a history of diarrhea during childhood and bilateral cataracts requiring surgery at 20 years of age, who evolves later with psychiatric disorders and bilateral increased volume in Achules tendons. High levels of plasmatic cholestanol and magnetic resonance imaging confirmed the diagnosis of this disease

Scientific Electronic Library Online (Spanish)

15

Lesiones de partes blandas en atletas de alto rendimiento/ Soft tissue lesions in high performance athletes/ Lésions des parties molles chez les athlètes à haute performance

Álvarez Cambras, Rodrigo; Jacobo Núñez, Marlene Elvira; Marrero Riverón, Luis Oscar; Castro Soto del Valle, Antonio
2004-12-01

Resumen en español En el presente trabajo se caracterizan las lesiones de tejidos blandos inducidas por actividades deportivas. Se analizan particularmente entre las lesiones osreomioarticulares, las que se obsertvan con más frecuencia en el campo de la traumatología del deporte en tendones, músculos y ligamentos. Resumen en inglés The present paper characterizes the soft tissue lesions induced by sports activities. A particular analysis was made on osteomioarticular lesions, mainly those more frequently observed in tendons, muscle and ligaments in the field of sport trauma.

Scientific Electronic Library Online (Spanish)

16

Design, implementation, and performance analysis of a Stewart platform-based force sensor

Roure Fernandez, Francisco; Frigola Alcalde, Roger; Ros Giralt, Lluís; Thomas Arroyo, Federico
2006-01-01

Digital.CSIC (Spain)

17

Autosomal recessive cerebellar ataxias

Palau Martínez, Francesc; Espinós, Carmen
2006-11-17

Digital.CSIC (Spain)

18

A wrench-sensitive touch pad based on a parallel structure

Frigola Alcalde, Roger; Ros Giralt, Lluís; Roure Fernandez, Francisco; Thomas Arroyo, Federico
2008-01-01

Digital.CSIC (Spain)