Sample records for FLUJO SUPERCRITICO (supercritical flow)
from WorldWideScience.org

Sample records 1 - 3 shown.



1

Presiones medidas en la base de una losa de fondo con juntas paralelas al flujo en un canal/ Measured pressures on the basis of bottom slab with gaps in the flow direction in a channel

Hurtado Orobio, Edwin; del Risco Moreno, Efraín; González Betancourt, Mauricio
2009-03-01

Resumen en español Se estudió si las aristas traseras de las juntas longitudinales de una losa de piso, fija al fondo de un canal con flujo supercrítico, convierten energía cinética en energía de presión en el rango de números de Froude de 2,84 a 10,12. En cada prueba, se midió la presión en 16 puntos de su cara inferior, con transductores piezoresistivos en tres líneas longitudinales: una central con 8 sensores y dos laterales, a lado y lado de la primera, con cuatro sensores cad (mas) a una. De esta forma, se determinó la distribución de las presiones medias debajo de la losa ensayada, similar a las usadas en obras civiles para evitar la acción erosiva de la turbulencia de un flujo supercrítico. El análisis de las presiones medidas muestra que, aún cuando las caras superiores del piso del canal y del bloque protector estén en el mismo plano horizontal, las aristas traseras de las juntas longitudinales transforman energía de velocidad en energía de presión. Así, se ha detectado un factor que interviene en la generación de la fuerza hidrodinámica que levanta revestimientos de diverso tipos de estructuras, hasta ahora ignorado en el estudio de este problema. Resumen en inglés A study was conducted to determine whether the back edges of the longitudinal gaps of a floor tile fixed to the bottom of a canal with a supercritical flow convert kinetic energy into pressure energy using Froude numbers in the range of 2.84 to 10.12. In each test the pressure was measured on 16 points on the bottom surface of the tile with piezo-resistive transducers along three longitudinal lines: one central line with 8 sensors and two lateral lines with 4 sensors each (mas) on either side of the central line. In this manner the distribution of the median pressures under the test tile was determined. The test tile is similar to those used in civil engineering structures for the purpose of avoiding the erosive action of the turbulence of a supercritical flow. The analysis of the measured pressures shows that even when the top surfaces of the canal floor and of the protective block are in the same horizontal plane, the back edges of the longitudinal gaps transform the energy of velocity into pressure energy. In such a way a factor has been identified that intervenes in the production of the hydrodynamic force that lifts revetments of different structures, and that has until now been ignored in the study of this problem.

Scientific Electronic Library Online (Spanish)

2

Hacia el desarrollo de técnicas analíticas rápidas para la detección de tóxicos y contaminantes en alimentos

Ramos, Lourdes; González, María J.; Fontecha, Javier

La OTRI del Centro Tecnológico Nacional de la Conserva y Alimentación junto con la OTT del Consejo Superior de Investigaciones Científicas, colaboran en el Proyecto AGROCSIC, el cual fue aprobado por el Ministerio de Ciencia y Tecnología y financiado por el Ministerio de Educación y Ciencia. El obje...

DRIVER (Spanish)