Sample records for strength fracture
from WorldWideScience.org

Sample records 1 - 20 shown. Select sample records:



1

Work of fracture of a composite resin: Fracture-toughening mechanisms

Baudín de la Lastra, Carmen; Osorio, Raquel; Toledano, Manuel; Aza Pendas, Salvador de
2008-01-01

Digital.CSIC (Spain)

2

Ultra-high–strength Bainitic Steels

García Mateo, Carlos; García Caballero, Francisca
2005-01-01

Digital.CSIC (Spain)

3

Threshold strength evaluation on an Al2O3–ZrO2 multilayered system

Bermejo, R.; Torres, Y.; Baudín de la Lastra, Carmen; Sánchez-Herencia, A.J.; Pascual, J.
2007-01-01

Digital.CSIC (Spain)

4

Propiedades mecánicas de cerámicos eutécticos Al2O3-ZrO2 (Y2O3) y Al2O3-YAG procesados por solidificación direccional

Salazar, A.; Pastor, J. Y.; Llorca, Javier; Peña Torre, José Ignacio; Francisco, I. de; Oliete, P. B.
2005-07-01

Digital.CSIC (Spain)

5

On the experimental study of the interface between a fiber composite lamina and concrete

Gettu, Ravindra; Cruz, José Sena; Barros, Joaquim A. O.; Santos, António Carlos dos; Bittencourt, Túlio

DRIVER (Spanish)

6

New Cementitious Materials Based on Alkali-Activated Fly Ash: Performance at High Temperatures

Fernández-Jiménez, Ana; Palomo, Angel; Pastor, José Y.; Martín, Antonia
2008-08-26

Digital.CSIC (Spain)

7

Multilayer coatings with improved reliability produced by aqueous electrophoretic deposition

Ferrari Fernández, Begoña; González, Sergio; Moreno, Rodrigo; Baudín, Carmen
2006-01-01

Digital.CSIC (Spain)

8

Mechanical properties and fractographical analysis by laser scanning confocal microscopy (LSCM) of laser textured Bi(Pb)-2212 superconducting materials

Capel, F.; Madre Sediles, María Antonieta; Sotelo Mieg, Andrés Emilio; Mora Alfonso, Mario; Diez, J. C.; López-Cepero, José M.
2006-10-01

Digital.CSIC (Spain)

10

Laser-assisted, crack-free surface melting of large eutectic ceramic bodies

Gurauskis, J.; Lennikov, V.; de la Fuente, G.F.; Merino Rubio, Rosa Isabel
2010-01-01

Digital.CSIC (Spain)

11

LA FALLA DE LA ROCA/ THE FAILURE OF ROCK

N.G.W., COOK
2009-11-01

Resumen en español Aparentemente no se tiene información disponible concerniente al comportamiento inelástico de las rocas fuertes, cuando el sistema comúnmente usado para determinar la resistencia de muestras de roca, llega a ser inestable inmediatamente después que se alcanza el pico de la relación deformación-esfuerzo, y cuando su pendiente alcanza a ser negativa. Se hace un análisis de los cambios de energía asociados con la extensión de fisuras tipo Griffith a tracción y comp (mas) resión, que muestran que el comportamiento inelástico puede ser descrito por el lugar geométrico curvo tipo Griffith. en el plano deformación-esfuerzos. Solamente cuando la pendiente (de ds) de este espacio geométrico es mayor a cero, el material es intrínsecamente frágil y pasible a una fractura espontánea. Cuando de ds es menor a cero, es posible que continúe la extensión de la fisura por fracturación inestable ó falla estable, dependiendo de la cantidad de energía suministrada al material por el sistema de aplicación de carga. El efecto del confinamiento triaxial reduce la pendiente negativa del lugar geométrico tipo Griffith y hace que el material sea más dúctil que cuando éste está bajo mía compresión uniaxial. La actividad micro-sísmica durante el ensayo de muestras de roca puede explicarse asumiendo que la roca es un material heterogéneo con inclusiones elásticas, y analizando la fractura de estas inclusiones en términos a lo expresado arriba. Se presentan datos experimentales obtenidos de ensayos de compresión uniaxial del mármol de Tennessee y el granito de Saint-Cloud y se muestran que están de acuerdo con las predicciones analíticas. Resumen en inglés Vírtually no infomation concerning the non-elastic behavior of hard rock is available. as the systems usually used to determine the strength of rock specimens become unstable as soon as the peak of the strain-stress characteristics is passed and its slope becomes negative. An analysis of the energy changes associated with the extensión of Griffith cracks in tensión and compression is made. which shows that the non-elastic behavior can be described by a curved Griffith (mas) locus in the strain-stress plane. Only when the slope of this locus de ds>0, is a material intrinsically brittle and liable to spontaneous fracture. When dé ds

Scientific Electronic Library Online (Spanish)

12

Influencia de la polimerización adicional en las propiedades de una resina Ormocer®/ Influencie of post-curing in Ormocer® mechanical properties

Gonçalves Mota, E; Mitsuo Silva Oshima, H; Henrique Burnett, L Jr.; Spohr, AM; Nogarett Pibernat de Carvalho, LM
2006-10-01

Resumen en español Los objetivos de este estudio fueron evaluar y comparar la influencia de la polimerización adicional con calor y presión de vapor o calor y nitrógeno presurizado en la resistencia a la compresión, módulo de elasticidad y microdureza Vickers de una resina compuesta Ormocer®;. Para esto, se confeccionaron 45 muestras cilíndricas con 3 mm de diámetro y 6 mm de altura en una matriz de PTFE. La resina compuesta Admira (Voco, Cuxhaven, Germany) fue introducida gradualme (mas) nte y fotopolimerizada por 40 s con el aparato XL-1500 (3M ESPE, St. Paul, MN, EUA). Seguidamente, las muestras fueron almacenadas en un horno a 37ºC por 24 horas y divididas aleatoriamente en tres grupos. Las muestras del grupo I (control) fueron testadas inmediatamente después del período de almacenamiento. En el grupo II, las muestras fueron sometidas a 120ºC bajo presión de vapor de agua por 20 min y, en el grupo III, las muestras fueron polimerizadas adicionalmente a 140°C con presión de 60 lbs. de nitrógeno durante 10 minutos. Inmediatamente, las muestras fueron testadas en una máquina de ensayo universal (Emic DL 2000, São José dos Pinhais, Paraná, Brazil) a 0,5 mm/min hasta que se fracturaron. Los valores de resistencia a la compresión (MPa), módulo de elasticidad (GPa) y microdureza Vickers (VHN) fueron tratados estadísticamente con ANOVA/Tukey (p Resumen en inglés The purposes of this study were evaluate and compare the influence of post-curing with heat and steam pressure or heat and nitrogen pressure in the compressive strength, elastic modulus and Vickers microhardness of an Ormocer®; composite resin. Forty-five cylindrical samples with 3 mm diameter and 6 mm high were manufacture using a PTFE mould. The composite resin Admira (Voco, Cuxhaven, Germany) was inserted incrementally and cured for 40 s with XL-1500 (3M ESPE, St. Pau (mas) l, MN, EUA). After that, the samples were stored in a stove at 37ºC for 24 hours and randomly divided in three groups. The samples of group I (control) were tested just after the stored period. In group II, the samples were submitted to 120ºC with water steam for 20 min, and for group III, the samples was post-cured at 140°C under 60 lbs of nitrogen for 10 min. The samples were tested with universal testing machine (Emic DL 2000, São José dos Pinhais, Paraná, Brazil) at 0.5 mm/min until fracture. Data of compressive strength (MPa), elastic modulus (GPa), and Vickers microhardness (VHN) were statistically evaluated with ANOVA/Tukey (p

Scientific Electronic Library Online (Spanish)

13

High-temperature mechanical behaviour of flaw tolerant alumina–zirconia multilayered ceramics

Bermejo, R.; Sánchez-Herencia, A.J.; Llanes, L.; Baudín de la Lastra, Carmen
2007-01-01

Digital.CSIC (Spain)

14

High-Temperature Tensile Strength of Er2O3-Doped ZrO2 Single Crystals

Pastor, José Y.; Llorca, Javier; Poza, Pedro; Quispe, José J.; Arellano López, A. R. de; Martínez-Fernández, Julián; Sayir, Ali; Orera, Victor M.
2006-04-13

Digital.CSIC (Spain)

15

Fracture toughness, strength and slow crack growth in a ceria stabilized zirconia–alumina nanocomposite for medical applications

Benzaid, Rajaa; Chevalier, Jérôme; Saâdaoui, Malika; Fantozzi, Gilbert; Nawa, Masahiro; Díaz, Luis Antonio

6 pages, 10 figures, 2 tables.-- Printed version published Sep 2008. | Mechanical properties and slow crack growth (SCG) behavior of a 10Ce-TZP/Al2O3 nanocomposite currently developed as a biomaterial are considered. Fracture toughness is determined for sharp, long (double torsion) and short (indent...

DRIVER (Spanish)

16

Fracture toughness, strength and slow crack growth in a ceria stabilized zirconia–alumina nanocomposite for medical applications

Benzaid, Rajaa; Chevalier, Jérôme; Saâdaoui, Malika; Fantozzi, Gilbert; Nawa, Masahiro; Díaz, Luis Antonio; Torrecillas San Millán, Ramón
2008-06-24

Digital.CSIC (Spain)

17

Estudio de la morfología de fractura de un acero inoxidable dúplex envejecido isotérmicamente a 475ºc/ Fracture morphology study of a duplex stainless steel isothermically aged at 475 ºc

Hilders, O.A; Ramos, M; Peña, N.D; Berrío, L; Ichaso, Y A
2007-01-01

Resumen en español Se ha estudiado el proceso de ruptura por tensión a temperatura ambiente en un acero inoxidable dúplex, luego de ser envejecido isotérmicamente a 475 ºC por tiempos comprendidos entre 1 y 120 h. Las superficies de fractura obtenidas fueron estudiadas mediante Microscopía Electrónica de Barrido (MEB) y los perfiles de fractura correspondientes, a través de un Analizador de Imágenes (AI). La Dimensión Fractal de estas superficies fue determinada mediante el Método (mas) de las Islas y relacionada con las propiedades mecánicas del material. Se observó el mecanismo de coalescencia de cavidades en el intervalo de tiempos comprendido entre 1 y 120 h, mientras que únicamente para las muestras tratadas por 120 h, se observó la formación incipiente de grietas secundarias de naturaleza intergranular. La resistencia general del acero se incrementó de forma continua con el tiempo de tratamiento, mientras que la ductilidad disminuyó. Por otra parte, la Dimensión Fractal aumentó desde la condición original (1,09), hasta la condición para 6,5 h (1,30), lo que fue asociado a un aumento de la complejidad de las cavidades en las superficies de fractura. Por el contrario, los valores de la Dimensión Fractal disminuyeron a partir de la condición para 6,5 h de envejecimiento (1,30), hasta la condición correspondiente a 120 h (1,05), cambio atribuido a la presencia de un menor tamaño de cavidad y al inicio de un proceso de agrietamiento secundario intergranular, obteniéndose entonces una menor irregularidad de las superficies de fractura respectivas. Resumen en inglés The tension fracture process at room temperature has been studied in a duplex stainless steel isothermically aged at 475 ºC between 1 and 120 h. The fracture surfaces were studied by means of scanning electron microscopy (SEM) and the fracture profiles by an Image Analyzer (IA). The Fractal Dimension of these surfaces was measured by the Slit Island Method, and their values were related with the mechanical properties. The micro-void coalescence mechanism of fracture was (mas) observed for the aging times ranged between 1 and 120 h, and intergranular microcracks were developed just for the aging condition of 120 h. The strength of the steel continuously increases with the aging time, and the ductility decreases. On the other hand, the Fractal Dimension increases from 1,09 (the as-received condition), to 1,30 (6,5 h of aging), which was related to the increased complexity of the micro-voids on the fracture surfaces. On the other hand, the Fractal Dimension decreases from 1,30 (6,5 h of aging), to 1,05 (120 h of aging). This behaviour was related to a smaller micro-void size, to the initial process of intergranular secondary cracking and to the smaller tortuosity of the corresponding fracture surfaces.

Scientific Electronic Library Online (Spanish)

18

Degradación ambiental de las propiedades mecánicas de fibras monocristallinas de circona dopada con erbia

Orera Clemente, Víctor Manuel; Pastor, J. Y.; Ridruejo, A.; Llorca, Javier; Sayir, Ali
2007-05-01

Digital.CSIC (Spain)

19

Control de la tenacidad de los hormigones reforzados con fibras usando el ensayo de doble punzonamiento (ensayo barcelona)/ Quality control of fiber reinforced concretes by mean of double punshing test (barcelona test)

Carmona Malatesta, Sergio; Aguado de Cea, Antonio; Molins Borrell, Climent; Cabrera Contreras, Manuel
2009-08-01

Resumen en español Tradicionalmente, se utiliza el ensayo de vigas prismáticas sometidas a flexión para caracterizar la resistencia y el comportamiento en el régimen post fisuración del hormigón reforzado con fibras (HRF). Sin embargo, estos ensayos presentan una alta dispersión en sus resultados cuestionando su empleo para el control sistemático del HRF en obras; tienen, además el inconveniente de tratarse de ensayos complejos que requieren de probetas pesadas y de personal de labo (mas) ratorio altamente calificado. Alternativamente, se ha propuesto el uso de otros ensayos normalizados de tracción directa e indirecta para realizar la caracterización de propiedades de los HRF, pero éstos han resultado ser muy complejos de ejecutar, sin obtener grandes mejoras en relación a la alta dispersión de los resultados. Con la finalidad de solucionar esta serie de inconvenientes, se ha propuesto el uso de un ensayo de tracción indirecta basado en una configuración del ensayo de doble punzonamiento, al que se ha denominado "Ensayo Barcelona". Este ensayo requiere de probetas de pequeñas dimensiones, con una alta superficie específica de fractura, permitiendo obtener valores representativos de la resistencia y de la tenacidad del material, con un coeficiente de variación de los resultados inferior al 13%, valor que es considerablemente menor a los alcanzados con otras metodologías experimentales. En este artículo se presentan los resultados de diferentes campañas experimentales, que permiten validar el uso del ensayo Barcelona como una metodología experimental adecuada para la sistemática caracterización del HRF en obras Resumen en inglés Traditionally, flexural testing of prismatic beams is used to characterize the strength and behavior in post - cracking regime of fiber - reinforced concretes (FRC). These tests exhibit a high dispersion in their results, and therefore invalidate the use of such tests for the systematic control of FRCs works. Also, they have the disadvantage of being complex tests, which require heavy specimens and highly qualified staff. The use of other standard tests of direct and indi (mas) rect tensile strength has also been intended, which have proved very complex to implement and also have high dispersion. Aiming to solve this set of problems, an indirect tensile test based on the configuration of double punching test, called the Barcelona test, has been proposed to control tensile behavior of FRC. This test requires smaller specimens, with a high specific surface of fracture, allowing to obtain values representative of strength and toughness of materials, with considerably less dispersion than other experimental methodologies. This paper presents the results of different experimental campaigns, which validate the use of Barcelona test as a suitable methodology to systematic characterization FRC in works

Scientific Electronic Library Online (Spanish)

20

Comportamiento mecánico de materiales cerámicos estructurales | Mechanical behaviour of structural ceramics

Bueno, S.; Baudín de la Lastra, Carmen

[ES] El uso de los materiales cerámicos en aplicaciones estructurales está limitado por la falta de fiabilidad asociada a su comportamiento frágil durante la fractura. Para extender su aplicación se ha propuesto el diseño de microestructuras que presenten tolerancia a los defectos debido a la actuac...

DRIVER (Spanish)

21

Comportamiento mecánico de materiales cerámicos estructurales

Bueno, Salvador; Baudín de la Lastra, Carmen
2007-05-01

Digital.CSIC (Spain)

22

Características mécanicas y microestructurales de materiales compuestos de matriz aluminio reforzados con partículas cerámicas de B 4 C, desarrollados por vía pulvimeta lúrgica.

Gómez Rodríguez, L.; Amigó Borrás, V.; Salvador Moya, M.D.; Busquets Mataix, D.; Martínez Mateos, N.
2003-01-01

Resumen en español Resumen A partir de polvos de aleación de aluminio AA6061, empleada como matriz y polvos cerámicos de carburo de boro (B 4 C), utilizados como refuerzo, se han desarrollado materiales compuestos por vía pulvimetalúrgica, seguida de un proceso de extrusión. Los resultados obtenidos de los ensayos mecánicos muestran un aumento significativo en la resistencia mecánica y en la dureza con el incremento en las fracciones volumétricas del refuerzo empleado, sobre todo pa (mas) ra aquellas muestras tratadas térmicamente, en las cuales, el endurecimiento por precipitación juega también un papel importante. Se comparan los valores de la resistencia máxima de los AMCs reforzados con B 4 C con aquellos reforzados con SiC en los cuales el efecto de las partículas de refuerzo sobre el endurecimiento es bien conocido. Los mecanismos de fractura, la distribución de refuerzos y la unión matriz-refuerzo, entre otros aspectos microestructurales de estos materiales, se han analizado mediante Microscopía Óptica (MO) y Microscopía Electrónica de Barrido (MEB). Resumen en inglés Abstract AA6061 based aluminum matrix composites reinforced with boron carbide (B4C) have been developed by a combined powder metallurgy and extrusion route. Mechanical testing on the composites showed a meaningful increase in hardness and strength as the reinforcement content was increased, both in the as extruded condition and after precipitation heat treatment on the matrix (T6). Ultimate tensile strength values of the B4C composites developed are compared with composi (mas) tes reinforced with SiC and processed in the same way, as in these last one have been extensively researched and the effect of SiC reinforcement on mechanical properties is well known. Finally, fracture mechanisms, reinforcement distribution and matrix - reinforcement interface, among other microstructural aspects in these materials, have been analyzed by means of optical (OM) and scanning electron microscopy (SEM).

Scientific Electronic Library Online (Spanish)

23

Análisis por elementos finitos de alúmina sometida a esfuerzos mecánicos y térmicos

Tomba Martinez, A.G.; Cavalieri, A.L.
2001-01-01

Resumen en inglés Disks of a commercial alumina were fabricated by slip casting, calcination and sintering. The surfaces were machined using SiC papers (120 and 320 grit) and characterized by residual stresses measurements. The mechanical strength was determined in biaxial flexure (ball on discontinuous ring). The specimens were subjected to thermal shock conditions (cooling using a high-velocity air jet) and the critical temperature differential for crack propagation was determined. The t (mas) emperature and stress distributions during air impinging were calculated using a finite element method. The value of the heat transfer coefficient was estimated by fitting the calculated temperature profiles with those measured during each test. The calculated tension for the thermal shock fracture was compared with the mechanical strength, together with the fracture features in each case. The differences were explained on the basis of the calculated stress distributions.

Scientific Electronic Library Online (Spanish)

24

Análisis biostático de las tensiones actuantes en el dentario del oso andino (Tremarctos ornatus), durante la mordedura/ Biostatical analysis of the tensions acting in the jaw of the Andean bear (Tremarctos ornatus) during the bite

DEL MORAL SACHETTI, J. Fernando; ZENTENO CÁRDENAS, Ramiro; LAMEDA CAMACARO, Fátima I.
2009-12-01

Resumen en español El presente estudio tuvo la finalidad de contribuir al conocimiento biológico y biostático del oso andino (Tremarctos ornatus), el cuarto úrsido de mayor tamaño del mundo y el carnívoro más grande viviente del Neotrópico. Se obtuvieron las tensiones máximas que solicitan al dentario durante la mordedura, sus reacciones y comportamiento a los esfuerzos de corte y momentos flexores máximos, a lo largo del vano mandibular. Para ello, se analizaron 3 cráneos complet (mas) os y un dentario provenientes de animales silvestres de Bolivia, utilizando 9 medidas craneanas como descriptores. Las cargas máximas de mordedura se consideraron en los caninos (c) y segundos molares superiores (m2). Se determinaron además la intensidad de las mismas, mediante el cálculo de las tensiones más elevadas alcanzadas en dichas secciones, en función de la Tensión de Rotura (σR = 0,50 kg/mm²). El sistema final propuesto, responde a dos tramos de una estructura hiperestática y su resolución se efectúo mediante el Método de Aproximaciones Sucesivas de Cross. Se encontró que la fuerza máxima de mordedura en el macho es de 246,90 kg siendo 1,34 veces mayor aproximadamente, en los molares. La hembra llega a tener una mordida de 184,96 kg y una intensidad de molienda de 285, 75 kg. El aumento de la intensidad, en más de 80 kg en los molares respecto a los caninos, es directamente proporcional al gran desarrollo del músculo temporal-masetérico; como el diseño estructural óseo en la fosa homónima y la anchura del rostro a nivel molar. Estos caracteres biostáticos denotan la especialización del diseño craneodentario de la especie para soportar grandes cargas; producto de triturar y moler vegetales fibrosos duros en general, y una capacitación singular del macho para la depredación. Lo que lo posibilita al oso andino a tener una dieta variada y oportunista en su nicho ecológico, adaptable a los recursos alimenticios que el medio le ofrezca. Resumen en inglés This study was intended to contribute to the biological and biostatical knowledge of the Andean bear, the fourth bear largest in the world and the largest carnivore living in the Neotropics. Tensions were high, asking the tooth during, their reactions and behavior cutting efforts and maximum flexor moments, along the jaw vain. This will be analyzed 3 complete skulls and a jaw from wild animals of Bolivia, using 9 skull measurements as descriptors. The maximum bite request (mas) s were considered in the canines (c) and second upper molars (m2). It also determined the intensity of them, by calculating of the tensions reached higher in these sections, depending on the Fracture strength (σR = 0.50 kg/mm²). The final system, responds to two portions of a hiperestatical structure and its resolution is achieved through the Moment Distribution Method by Cross. It was found that the maximum bite force in the male is 246.90 kg being 1.34 times higher in the molars. The female, have reached a bite of 184.96 kg and a milling intensity of 285.75 kg. The increased intensity in over 80 kg in the molars on the canines is directly proportional to the great development of the temporalis-masseteric muscle, as the structural design of bone in the masseteric fossa and the width of face at molar. These biostatics characters reflect the design expertise craniodental of the species to withstand major stresses, product of crushing and grinding tough fibrous plants in general and training unique to the male predation. What it enables the Andean bear to have a varied diet and opportunistic in its ecological niche, adaptable to food resources that the environment offered.

Scientific Electronic Library Online (Spanish)

25

Analisis comparativo entre los experimentos mecanicos de cizallamiento y microcizallamiento

Viégas Montenegro, Robinsom; da Cunha Uchôa, Roseanne; Lira Montenegro, Sheila Cristhinne; Lira, Arine; Japiassú, Marcus; Fonseca da Silveira, Márcia; Brito Pereira de Melo, Ângelo
2008-01-01

Resumen en español Esta investigación analizó comparativamente los ensayos mecánicos de cizallamiento y microcizallamiento, a través de una evaluación de resistencia de unión dentina-compósito, utilizando dos técnicas de unión (autocondicionante y condicionamiento ácido total). Las coronas de cuarenta incisivos de bovinos fueron incluidas em tubos de PVC con resina acrílica. Las caras vestibulares fueron desgastadas hasta la exposición de tejido dentinario con hojas de lijar de (mas) carburo de silicio. Para la técnica de cizallamiento se delimito un área de 4mm de diámetro donde fue aplicado el sistema adhesivo de acuerdo con instrucciones del fabricante. Un cilindro de compósito restaurador (Filtek Z250 - 3M ESPE) de 4mm de diámetro y altura de 5mm fue construido en el área. Las muestras para el microcizallamiento fueron confeccionadas utilizando tubos de Tygon con diámetro interno de 0,7 mm y altura de 0,5mm en los cuales el mismo compósito restaurador fue colocado. La carga para ambos experimentos fue realizada a una velocidad de 1.0mm/min con alambre de ortodoncia de 0,3mm de diámetro. Los resultados muestran que para el experimento de cizallamiento el Adper Single Bond presentó valores estadísticamente superiores AL Clearfil SE Bond (p = 0,037). Para el microcizallamiento no hubo diferencias estadísticas (p = 0,780). Los cuerpos de prueba fueron sometidos al análisis de microscopia electrónica de barrido para clasificar el tipo de fractura. En el experimento de cizallamiento, existieron fallas adhesivas, cohesivas y mixtas en dentina para los dos sistemas adhesivos. En el experimento de microcizallamiento, se observó alta prevalencia de fallas adhesivas. Los resultados permitieron concluir que el microcizallamiento se mostró más apropiado para evaluar la resistencia de la unión adhesiva en la interfase compósito/dentina. Resumen en inglés The aim of this study was to evaluate comparatively the methodology of micro-shear and shear bond strength using the two available bonding strategies self etching and total etching techniques. Forty bovine incisors were cut and embedded in PVC tubes with acrylic resin. The buccal surfaces were flattened and exposed with SiC paper. For the shear bond strength test, an area of 4mm in diameter was delimited and the adhesive systems were applied according to the manufacturer' (mas) s instructions. A composite cylinder (Filtek-Z250 - 3M ESPE) of 4mm diameter and 5mm height were built in the area. The samples for microshear were made use of Tygon tubes with 0,7mm in internal diameter in 0,5mm height, using the same composite. Loading were carried out at crosshead speed of 1,0mm/min using an orthodontic wire loop of 0,3mm diameter. The results showed that for shear test the Adper Single Bond presented higher values with statistical significance to Clearfil SE Bond (p=0,037). For the micro-shear test statistical difference was not observed (p=0,780). The samples were submitted to SEM for a fracture pattern classification. For the shear bond test were observed adhesive and dentin cohesive failures for both adhesive systems. For micro-shear bond test were observed a high prevalence of adhesive failures. According to the results it was possible to conclude that micro-shear bond test was more appropriated to evaluate the resistance of bond strength in interface composite/dentin.

Scientific Electronic Library Online (Spanish)