Sample records for espacio refrigerado (space cooling)
from WorldWideScience.org

Sample records 1 - 9 shown.



1

Structure and magnetic properties of RNi2Mn compounds (R=Tb, Dy, Ho, and Er)

Wang, J. L.; Marquina, Clara; Ibarra, M. Ricardo; Wu, G. H.
2006-03-01

Digital.CSIC (Spain)

2

Structural, spectroscopic, and tunable laser properties of Yb3+-doped NaGd(WO4)2

Cascales, Concepcion; Serrano, Maria Dolores; Esteban-Betegon, Fatima; Zaldo, Carlos; Peters, Rigo; Petermann, Klaus; Huber, Guenter; Ackermann, L; Rytz, Daniel; Dupre, C; Rico, Mauricio; Liu, Junhai; Griebner, Uwe; Petrov, Valentin
2006-11-20

Digital.CSIC (Spain)

3

Nonoxidized Al-overcoated Ir bilayers with high reflectance in the extreme ultraviolet above 50 nm

Larruquert, Juan Ignacio; Méndez, José Antonio; Aznárez, José Antonio
2002-05-22

Digital.CSIC (Spain)

4

Metal-insulator transition in Nd1-xEuxNiO3 compounds

Escote, M.T.; Barbeta, V.B.; Jardim, R.F.; Campo, Javier
2006-07-01

Digital.CSIC (Spain)

5

Investigation of the thermotropic behavior of isomer mixtures of diacyl arginine-based surfactants. Comparison of polarized light microscopy, DSC, and SAXS observations

Morán, María del Carmen; Pinazo Gassol, Aurora; Clapés Saborit, Pere; Pérez, L.; Infante, María Rosa; Pons Pons, Ramón
2004-06-22

Digital.CSIC (Spain)

6

Efecto de un sistema de enfriamiento a espacio abierto en la eficiencia productiva de novillos holstein durante el verano

Correa-Calderón, Abelardo; Yáñez, Víctor; Verdugo, Francisco; Pérez, Adolfo; Avendaño, Leonel; González, Víctor Manuel; Ponce, Francisco; Tarazón, Mario
2004-02-01

Resumen en portugués Para avaliar os efeitos de um sistema de esfriamento a espaço aberto no aumento de peso, consumo de alimento e frequência respiratória utilizaram-se 32 novilhos Holstein de 373 kg, distribuídos em dois tratamentos de um projeto ao azar com medições repetidas. Um tratamento foi únicamente sombra na parte central do curral (grupo testemunha; n=16) e um segundo tratamento contou con un sistema de esfriamento a espaço aberto (n=16). Dito sistema consistiu em um leque (mas) com uma hélice de 2,4m de diâmetro produzindo um volume de ar de 1.416 m³/min com uma cobertura de oscilação de 90º. Os aspersores instalados no sistema liberaram uma quantidade de água de 12 l/min. O estudo teve uma duração de 90 dias, registrando-se neste período um índice máximo de temperatura-umidade em uma faixa de 84 a 90. O aumento de peso foi similar (P>0,05) entre o grupo testemunha e o esfriado (1,34 ±0,05 vs 1,41 ±0,05kg/día, respectivamente) assim como o consumo de alimento (9,9 vs 10,5 kg/dia). No entanto, observou-se uma tendência a incrementar a eficiência produtiva e uma redução (P Resumen en español Para evaluar los efectos de un sistema de enfriamiento a espacio abierto en la ganancia de peso, consumo de alimento y frecuencia respiratoria se utilizaron 32 novillos Holstein de 373kg, distribuidos en dos tratamientos de un diseño al azar con mediciones repetidas. Un tratamiento fue únicamente sombra en la parte central del corral (grupo testigo; n=16) y un segundo tratamiento contó con un sistema de enfriamiento a espacio abierto (n=16). Dicho sistema consistió en (mas) un abanico con una hélice de 2,4m de diámetro produciendo un volumen de aire de 1416m³/min con una cobertura de oscilación de 90º. Los aspersores instalados en el sistema liberaron una cantidad de agua de 12l/min. El estudio tuvo una duración de 90 días, registrándose en este período un índice de temperatura-humedad máximo en un rango de 84 a 90. La ganancia de peso fue similar (P>0,05) entre el grupo testigo y el enfriado (1,34 ±0,05 vs 1,41 ±0,05kg/día, respectivamente) así como el consumo de alimento (9,9 vs 10,5kg/día). Sin embargo, se observó una tendencia a incrementar la eficiencia productiva y una reducción (P Resumen en inglés To evaluate the effects of an open space cooling system on weight gain, feed intake and respiration rate, 32 Holstein steers (373kg) were randomly assigned in two treatments, a control group with shade only in the pen (n=16) and a second group with an open space cooling system (n=16). The open space cooling system consisted of a 2.4m diameter blade fan circulating 1416m³/min of air, with oscillation coverage of 90º. The amount of water discharged was 12l/min. The study (mas) was conducted for 90 days with a daily maximal temperature-humidity index (THI) of 84 to 90. There was no difference (P>0.05) in daily weight gain (1.34 ±0.05 vs 1.41 ±0.05kg/day) or feed intake (9.9 vs 10.5kg/day) for control and cooling groups, respectively. However, there was a tendency to increase the productive performance and to reduce the respiration rate (P

Scientific Electronic Library Online (Spanish)

7

Chemical Evolution of the Circumstellar Envelopes of Carbon-rich Post-AGB objects

Herpin, F.; Goicoechea, Javier R.; Pardo Carrión, Juan Ramón; Cernicharo, José
2002-06-11

Digital.CSIC (Spain)

8

Aire Acondicionado Solar, para Conjunto de Viviendas en Mexicali, México/ Solar Air Conditioning for a Housing Compound in Mexicali, Mexico

Luna, Aníbal; Velázquez, Nicolás; Gallegos, Ricardo; Bojorquez, Gonzalo
2008-01-01

Resumen en español El objetivo del presente trabajo es dimensionar y evaluar un sistema de enfriamiento por absorción LiBr-H2O asistido con energía solar y gas natural, para climatizar un conjunto de viviendas en Mexicali, Baja California, México. El análisis de comportamiento horario, diario y mensual en el periodo con mayor demanda de enfriamiento se realiza con el programa TRNSYS 16 y se busca la menor área de captación y la mayor fracción solar. Esto se traduce en el mínimo cost (mas) o de operación e inversión inicial. Se encontró que el sistema genera condiciones del espacio entre confortablemente caliente y confortablemente frío, según la norma ISO 7730 (2005). Esto se logra a partir de 287 m²detubos evacuados, que aportan el 90% de la energía requerida. El sistema es técnicamente factible, ya que cubre la demanda de enfriamiento durante el periodo de verano y requiere un área de colección similar a la disponible en el conjunto de viviendas Resumen en inglés The objective of the present work is to dimension and evaluate an absorption LiBr-H2O cooling system assisted by solar energy and natural gas for air conditioning of a group of housings in Mexicali, Baja California, Mexico. The analysis of the hourly, daily and monthly operating performance in the period with more cooling demand is carried out by mean of TRNSYS 16, and it is seeking the least collection area and the highest solar fraction; that which is translated in the (mas) minimum operation cost and initial investment. It was found that the system generates conditions of the space between comfortably warm and comfortably cold, according to ISO 7730 (2005), with 287 m² of evacuated tubes which contribute 90% of the required energy. The system is technically feasible, since it covers the cooling demand during the summer period and it requires a similar collecting area to the available one in the housing compounds

Scientific Electronic Library Online (Spanish)

9

A raman study of order-disorder phenomena in Zn1−x Mnx Ga2 Se4 compounds

Alonso-Gutiérrez, P.; Sanjuan Álvarez, María Luisa; Morón, M. Carmen
2007-04-01

Digital.CSIC (Spain)