COLECTOR SOLAR CONSTRUIDO MEDIANTE TALADRADO POR FLUENCIA TÉRMICA

Heredia R, Víctor; Tapia L, Juan; Flores C, Camilo; Godoy R, Juan M.; Vergara Díaz, Jorge
2005-08-01

Resumen en español Se diseñó y construyó un sistema de calentamiento de agua residencial, mediante dos colectores solares y un estanque. En el sistema se utilizaron tubos de cobre perforados por taladrado por fluencia térmica (TFT), unidos con soldadura de plata. El sistema funciona por termosifón y se emplea como fluido de calentamiento una mezcla de etilenglicol-agua. El fluido de calentamiento pasa a través de un serpentín de cobre a un estanque de 200 litros. Diariamente se calientan 80 litros de agua a una temperatura máxima de 45º C Resumen en inglés A heating equipment for residential water was built, using two solar collectors and one isolated reservoir. The system uses to copper tubes perforated by thermal flow drilling (TFT), brazing with silver solder. The thermal fluid moves due to the density change of the cold and hot water. It is a mixture of ethyleneglycol-water and the heat is exchanged in the copper serpentine installed in the reservoir of 200 liters. Daily it warms 80 liters of water to 45ºC

Scientific Electronic Library Online (Spanish)

2

EVALUACIÓN DE ALTERNATIVAS PARA CLIMATIZACIÓN DE ESTANQUES CON ENERGÍA SOLAR PARA CULTIVO DE TILAPIA ROJA (Oreochromis sp), LOCALIZADOS EN LA ZONA FRÍA DEL VALLE DEL CAUCA, COLOMBIA/ EVALUATION OF ALTERNATIVES FOR AIR CONDITIONING OF PONDS WITH SOLAR ENERGY FOR CULTIVATION OF RED TILAPIA (Oreochromis sp), LOCATED IN THE COLD AREA OF THE CAUCA VALLEY, COLOMBIA

Borja Gallardo, Francisco Javier; González Salcedo, Luis Octavio; Quintero de Vallejo, Victoria Eugenia
2006-06-01

Resumen en español La investigación fue desarrollada para que la tilapia roja (Oreochromis sp), especie de pez mÁs producida en Colombia, pueda ser explotada en lugares donde las condiciones óptimas para su normal desarrollo no son las adecuadas, como son las regiones altas con temperaturas por debajo de los 24 °C, aplicando metodologías relacionadas con el aprovechamiento de la energía solar. Las técnicas evaluadas fueron: climatización por medio de colectores solares, climatizaci� (mas) �n por medio de manta térmica, climatización por medio de mangueras térmicas y climatización por medio de resistencias eléctricas. Se analizaron factores como funcionalidad, mantenimiento, limitaciones organizativas, espaciales, y costos. Resumen en inglés The research was developed so that the red tilapia (Oreochromis sp), fish species that more taken place in Colombia can be exploited in regions where the good conditions for its normal development are not the appropriate ones as in the high regions with temperatures below the 24 °C, applying methodologies related with the use of the solar energy. The evaluated methodologies were: air conditioning by means of solar collectors, air conditioning by means of thermal blanket, (mas) air conditioning by means of thermal hoses and air conditioning by means of electric resistances. Factors like functionality, maintenance, organizational and space limitations, and costs were analized.

Scientific Electronic Library Online (Spanish)

3

Estudio de la fotodegradación del clorotalonilo usando las técnicas de fenton y fotocatálisis con dióxido de titanio mediante radiación solar/ Chlorothalonil photodegradation study using Fenton and photocathalysis techniques with titanium dioxide by means of solar radiation

Vásquez, Esmeralda; Peñuela, Gustavo; Agudelo, Sergio
2010-02-01

Resumen en español Para el diseño de sistemas de tratamiento de afluentes residuales se requiere determinar el tiempo de degradación de los contaminantes a escala y con dicha información se puede calcular el tiempo de residencia del agua en el tratamiento seleccionado. En los sistemas de tratamiento con colectores solares, el tiempo de fotodegradación del contaminante dependerá de la intensidad de radiación solar, la cual varía con la hora del día y las condiciones ambientales. En e (mas) l presente trabajo mediante un colector solar se evaluó la fotodegradación del plaguicida Clorotalonilo con dióxido de titanio y con el reactivo de Fenton, respectivamente, realizándose los ensayos en la ciudad de Medellín (6º latitud norte y 1570 metros sobre el nivel del mar, msnm). El 95% de la degradación del Clorotalonilo se alcanzó con 500 mg/l de TiO2 y 1,0 mg/l de persulfato de sodio en 4 horas de irradiación solar, con una energía acumulada de 15,1 kJ/l. Igual porcentaje se alcanzó con 10 mg/l de ión Férrico en 18 horas de irradiación solar con una energía acumulada de 38 kJ/l. La cinética de degradación fue de primer orden con ambas técnicas de tratamiento, pero con el dióxido de titanio se obtuvo una mayor constante de degradación y un mayor grado de mineralización (80%) que con el foto-Fenton (72%). La mineralización de los compuestos orgánicos (Clorotalonilo y subproductos de degradación) se comprobó por la desaparición del carbono orgánico total (COT) y la formación de cloruros y nitratos. Se detectaron 6 productos de degradación que a pesar de su baja concentración pueden ser los responsables de la alta toxicidad del efluente final en los bioensayos con Dapnhia pulex. Resumen en inglés For the design of wastewater treatment systems it is required to determine the degradation time of the pollutants to scale, and with said information the residence time of the water in the selected treatment can be calculated. In treatment systems with solar collectors, the photodegradation time of the pollutant will depend on the intensity of the solar radiation, which varies with the time of day, and the environmental conditions. In this research work the photodegradati (mas) on of the pesticide Chlorothalonil with titanium dioxide and with Fenton reactive, respectively, was evaluated using a solar collector. The experiments were carried out in the city of Medellín (6º North latitude, 1570 meters above sea level, m.s.l.). 95% of the Chlorothalonil degradation was reached with 500 mg/l TiO2 and 1,0 mg/l sodium persulfate in 4 h of solar irradiation, with an accumulated energy of 15,1 kJ/l. The same percentage was reached with 10 mg/l ferric ion in 18 hours of solar irradiation with an accumulated energy of 38 kJ/l. The degradation kinetics was first order with both treatment techniques, but a higher degradation constant and a higher mineralization degree (80%) was obtained with titanium dioxide compared with photofenton (72%). The organic compounds mineralization (Chlorothalonil and degradation subproducts) was verified by the disappearance of the total organic carbon (TOC) and the chlorides and nitrates formation. Six degradation products were detected, and in spite of their low concentration, they can be responsible of the high toxicity of the final effluent in the bioassays with Dapnhia pulex.

Scientific Electronic Library Online (Spanish)

4

SIMULACIÓN HORARIA DE UN SISTEMA DE REFRIGERACIÓN COMBINADO EYECTOR-COMPRESIÓN DE VAPOR ASISTIDO POR ENERGÍA SOLAR Y GAS NATURAL/ HOURLY SIMULATION OF A COMBINED EJECTOR-VAPOR COMPRESSION REFRIGERATION SYSTEM ASSISTED BY SOLAR ENERGY AND NATURAL GAS

Vidal, Humberto; Colle, Sergio
2009-04-01

Resumen en español Entre los sistemas de refrigeración movidos térmicamente asistidos por energía solar y gas natural, el sistema de refrigeración con eyector ha recibido especial atención. Este sistema se caracteriza por su simplicidad constructiva, ausencia de partes móviles, operación en bajas temperaturas y bajo costo operacional. Sin embargo, el ciclo de refrigeración por eyector tiene usualmente un bajo coeficiente de desempeño. Una alternativa de solución a este problema lo (mas) constituye el sistema de refrigeración con eyector combinado. La primera etapa está constituida por un ciclo de compresión mecánica de vapor convencional con R134a, mientras que la segunda etapa la constituye un ciclo termo-movido con eyector usando R141b como fluido de trabajo. Colectores de placa plana y un quemador de energía auxiliar entregan calor al ciclo de eyector. Este artículo describe la simulación en base horaria de un sistema de refrigeración combinado eyector-compresión de vapor asistido por energía solar y gas natural. El sistema de refrigeración solar combinado es modelado usando la herramienta de simulación TRNSYS-EES y los datos climáticos de un año típico de Florianópolis, Brasil. Los resultados obtenidos con la modelación computacional desarrollada para este sistema muestran la ventaja del ciclo de refrigeración combinado eyector-compresión de vapor por sobre el ciclo simple con eyector. Finalmente, el modelo computacional desarrollado en este artículo podría ser usado para realizar una optimización termo-económica del sistema en trabajos futuros Resumen en inglés Among the thermally driven cooling systems assisted by solar energy and natural gas, the ejector cooling system has received special attention. This system is an interesting refrigeration technology due to its construction simplicity, absence of moving parts, operation at lower temperatures and a low operational cost. However, the coefficient of performance of ejector cycle is usually low. The double stage ejector cooling cycle assisted by solar energy system appears as a (mas) n attractive solution to this problem. The first stage is performed by a mechanical compression cycle with R-134a as the working fluid, while the second stage is performed by a thermally driven ejector cycle with R-141b. Flat plate collectors and an auxiliary energy burner provide heat to the ejector cycle. This paper describes the hourly simulation of a combined ejector-vapor compression refrigeration system assisted by solar energy and natural gas. The combined solar refrigeration system is modeled using the TRNSYS-EES simulation tool and the typical meteorological year data containing the weather data of Florianópolis Brazil. The results obtained from the computational simulation performed in this system show that the combined ejector-vapor compression cooling cycle is more advantageous than the simple ejector cooling cycle. Finally, the computational model developed in this paper might be used to perform a thermo-economical optimization of the system in future works

Scientific Electronic Library Online (Spanish)

5

Energy and carbon emission savings in Spanish housing air-conditioning using solar driven absorption system

Rodríguez Hidalgo, M.C.; Rodríguez Aumente, P.; Izquierdo Millán, M.; Lecuona Neumann, Antonio; Salgado Manguala, R.
2008-10-01