Sample records for FUENTES DE CALOR (heat sources)
from WorldWideScience.org

Sample records 1 - 17 shown.



1

Evaluación de de la eficacia de los procesos de esterilización de consultorios odontológicos del distrito VI de la provincia de buenos aires, argentina 2006 - 2007, mediante la utilización de indicadores biológicos

Riera, Laura Marisa C; Maiztegui, Julio I; Ambrosio, Ana María; Bottale, Alejandro Javier; Nandín, Lourdes; Fassio, Rubén; Saavedra, María del Carmen; Castellano, Laura; Dowhuszko, Adolfo; Di Fulvio, Silvio; Ceuninck, Amanda
2009-06-01

Resumen en español En un consultorio odontológico, diversas fuentes de posible infección, como saliva, sangre, instrumentos contaminados, etc., pueden ser transmisores de microorganismos tanto a pacientes como al personal odontológico. El objetivo del presente trabajo fue evaluar la eficacia de los procesos de esterilización de los consultorios odontológicos del Distrito VI de la Provincia de Buenos Aires mediante la utilización de Indicadores Biológicos. Participaron del estudio 283 (mas) odontólogos que llevaron a cabo un total de 320 procesos de esterilización por calor seco y 19 por calor húmedo. En base a los resultados obtenidos se observó que el 35 % (112/320) de los procesos de esterilización por calor seco controlados no cumplieron con los requisitos, de los cuales 63 repitieron el control y, 55/63 (87%) resolvieron el problema mediante distintas acciones correctivas. Con respecto a la esterilización por calor húmedo, el 32 % (6/19) de los procesos no cumplieron con los requisitos, en 3 de los 6 positivos se efectuaron correcciones simples obteniéndose resultados satisfactorios. El presente trabajo muestra la importancia para la comunidad, de la implementación de rutina de un sistema de control que permita garantizar la esterilidad de los materiales utilizados en los consultorios odontológicos. Resumen en inglés In a dental office, several infectious sources, such as saliva, blood, contaminated dental instruments, may be vehicles for microorganisms to reach patients and dental proffesionals. In this work the efficacy of the sterilization process performed at dental offices belonging to the VI district of Buenos Aires Province from Argentina was evaluated through the use of Biological Indicators. Two hundred and eigthy three dentists participated of the study performing a total of (mas) 320 dry heat sterilization process and 19 wet heat ones. It was observed that the 35 % (112/320) of the dry heat sterilization process controlled didn't meet the requirements, 63 of which repeated the control and 55 (87%) solved the problem through the adoption of several corrective actions. In relation to wet heat sterilization, the 32 % (6/19) of the process didn't meet the requirements, 3 out of 6 positives overcame the problem after the implementation of corrective actions. These results show the importance for the whole community of a control program implementation in order to guarantee the sterility of the instruments used in the dental practice.

Scientific Electronic Library Online (Spanish)

2

Riesgo químico en el Laboratorio de Análisis del Centro de Estudios de Biotecnología Industrial/ Chemical risk in the analysis laboratory of the Industrial Biotechnology Studies Center

Ábalos Rodríguez, Arelis; Aguilera Rodríguez, Isabel; Pérez Silva, Rosa María
2010-08-01

Resumen en español Se llevó a cabo un ensayo clínico para evaluar el riesgo químico en el laboratorio de análisis del Centro de Estudios de Biotecnología Industrial de la Facultad de Ciencias Naturales de la Universidad de Oriente, con vista a lo cual se identificaron, entre otros aspectos, las características generales del local y de las 20 técnicas establecidas para el análisis de aguas residuales y residuales agroindustriales (11 de estas se aplican 200 veces al año como promedi (mas) o), frecuencia de los análisis, reactivos químicos empleados y su categoría de peligro (fundamentalmente ácidos minerales, álcalis, solventes orgánicos y oxidantes fuertes), así como se evaluaron los riesgos químico-físicos y las medidas laborales de seguridad, incluido el tratamiento de los residuos antes de ser eliminados. Se observó que los analistas están expuestos a fuentes de calor y vapores de solventes y ácidos a través de la piel y el sistema respiratorio, pero en un trienio solo se produjeron 3 accidentes leves y no hubo certificados médicos por enfermedades ocupacionales en este tipo de instalación. Resumen en inglés A clinical trial to evaluate the chemical risk was carried out at the analysis laboratory of the Industrial Biotechnology Studies Center in the Natural Sciences Faculty at Oriente University. For this purpose, aspects such as the general characteristics of the site and of the 20 established techniques for the analysis of waste waters and agroindustrial residual were identified, (11 of these were applied 200 times a year as average), frequency of the analyses, chemical rea (mas) gents used and their danger category (fundamentally mineral acids, alkalis, organic solvents and strong oxidizers), as well as the chemical-physical risks and the security working measures were evaluated, including the treatment of residuals before being eliminated. It was observed that the analysts are exposed to sources of heat and steam of solvents and acids through the skin and the respiratory system, but just 3 mild accidents took place in a triennium, and there were no medical certifications due to occupational diseases in this type of facility.

Scientific Electronic Library Online (Spanish)

3

Numerical study of transverse flow through banks of tubes using curvilinear coordinates

Rojo, Jesús; Rincón, José; Reyes, Miguel
2002-04-01

Resumen en español El objetivo de este trabajo es desarrollar un método numérico para calcular el flujo laminar a través de arreglos de tubos tales como los que se encuentran en los intercambiadores de calor. Para lograr este propósito, se utiliza una malla no-desplazada en coordenadas curvilíneas y las ecuaciones que describen el flujo se resuelven mediante el método de los volúmenes finitos. El procedimiento de solución utiliza las componentes cartesianas de velocidad como variabl (mas) es dependientes y un método similar al SIMPLER para lograr el acoplamiento de los campos de velocidad y de presión. Los términos convectivos se aproximan utilizando un tratamiento de alto orden. El modelo numérico se aplica a varios casos en régimen laminar y los resultados obtenidos se comparan con trabajos experimentales y numéricos de varias fuentes, demostrando que el método es estable y preciso para el rango de números de Reynolds considerados. Resumen en inglés The scope of this work is to develop a numerical method to calculate the laminar flow through tube arrangements such as those in heat exchangers. To achieve this purpose, a non-staggered grid arrangement in curvilinear coordinates is used. The differential equations that describe the flow and heat transfer are transformed and expressed in a conservative form. The discretisation of the governing equations is carried out using the integration by means of the finite volumes (mas) method. The solution procedure uses the Cartesian components of velocity as dependent variables and the SIMPLER method to attain the pressure-velocity field coupling. Convective terms are approximated by using a high order treatment. The numerical model was applied to several cases in laminar regime and the predictions obtained were compared with experimental and numerical works of several bibliographic sources, showing that the method is stable an accurate for the range of Reynolds numbers studied.

Scientific Electronic Library Online (Spanish)

4

Características, propiedades, patogenia y fuentes de exposición del asbesto/ Asbestos: characteristics, properties, pathogenesis and sources of exposure

Abú-Shams, K.; Pascal, I.
2005-01-01

Resumen en español El asbesto es un mineral fibroso conocido desde antiguo, utilizado ampliamente en la industria debido a sus propiedades físicas y químicas que lo hacen muy adecuado para dicho fin. Los tipos de asbesto se clasifican en grupo serpentina y en anfiboles según la configuración curvada o recta de sus fibras. En cuanto a sus propiedades destacan la resistencia al calor, al desgaste, a los álcalis y ácidos y su flexibilidad entre otras características que lo hacen un mate (mas) rial adecuado para ser utilizado como aislante, en la industria textil y en otros muchos campos. Es conocido desde hace años el riesgo patogénico del amianto al permanecer tiempo en el tejido pulmonar, atribuyéndole según los estudios la alteración de la actividad mucociliar del huésped, la activación macrofágica y la liberación de mediadores inflamatorios así como un aumento de su poder oncogénico al asociarse al humo del tabaco e incluso a ciertos virus. Resumen en inglés Asbestos is a fibrous mineral that has been known since ancient times. It is widely used in industry due to its physical and chemical properties which make it highly suitable for this end. Asbestos is classified in two groups - serpentine and amphibole - depending on the curved or straight configuration of their fibres. Outstanding amongst its properties are its resistance to heat, wear, alkalis and acids, and its flexibility, amongst other characteristics, which make it (mas) a suitable material for use as insulation, in industrial textiles and in many other fields. The pathogenic risk of asbestos remaining for a long time in the pulmonary tissue has been known for many years; studies attribute it with alteration of the mucociliary activity of the host, macrophage activation and the freeing of inflammatory mediators as well as an increase in their oncogenic strength on association with tobacco and even some viruses.

Scientific Electronic Library Online (Spanish)

5

¿Hubo infectólogos en la Antigua Roma?/ Were there infections diseases specialists in the Ancient Rome?

Ledermann D, Walter
2010-04-01

Resumen en español Si mal pudo haber infectólogos en la Antigua Roma, hubo al menos intelectuales capaces de agudas observaciones en materia de infecciones, con merecimientos suficientes para postularse como nuestros predecesores: Varrón, Columela y Vitruvio, ninguno de ellos médico. Varrón, en el primero de sus Libros de Agricultura, recomendaba ubicar la casa evitando los pantanos, porque allí crecen ciertos animales, tan diminutos que no se pueden seguir con los ojos y flotan en el (mas) aire y entran al cuerpo por la boca y la nariz causando graves enfermedades. También en un texto de agricultura y en el mismo sentido, Columela dice que una laguna desprende con los calores un vapor pestilencial y produce enjambres espesísimos de insectos, que vienen volando sobre nosotros armados de aguijones dañinos... Vitruvio, el gran arquitecto, se ocupó del agua potable: sus fuentes y sus cualidades, cómo obtenerla y los métodos para probar su calidad. Esta preocupación por la distribución de aguas y disposición de excretas había nacido en el 614 A.C., poco después de la fundación de Roma, con la construcción del primer acueducto, el Aqua Marcia, para alcanzar en tiempos de Trajano (siglo II D.C.) un total de 443 km, con 49.500 metros de arcadas de hasta 32 metros de altura, más 2,4 km de red subterránea. Éstos entregaban 947.200 m³ por día, de los cuales dos tercios eran para uso público y un tercio privado Resumen en inglés The existence of infectious diseases specialists in Ancient Rome is unlikely, but there were at least three authors able of keen observations on infectious matters, with enough merit to be considered our predecessors: Varro, Columella and Vitruvius, none of them physicians. Varro, in his first Book on Agriculture recommended, "Build the houses distant from swamps, because certain minute creatures are bred which cannot be followed with the eyes but which float in the air a (mas) nd enter the body through the mouth and nose, giving rise to severe diseases". Also in a text of agriculture and in the same sense, Columella says "that with heat a swamp releases a pestilential vapor and produces a very dense swarm of insects, which come flying over us armed with harmful stings Vitruvius, the great architect was worried about drinkable water: its sources and properties, how to obtain it and the methods for testing its quality. The concern on its distribution and disposal of sewage started on 614 B.C., little after the foundation of Rome, with the building of the first aqueduct, the Aqua Marcia. This aqueduct in Trajan's times (century II A.D.), reached a total of 443 km, with 49,500 meters of arcades, which were up to 32 meters high, plus 2.4 Km. of an underground net. This system released 947.200 m3 of water per day, two thirds of which were for public use and one third for private customers

Scientific Electronic Library Online (Spanish)

6

Proyecto de construcción en La Pereda de una Planta Piloto de Captura de CO2 por Postcombustión Mediante Ciclos de Carbonatación - Calcinación

Abanades García, Juan Carlos; Zarraga, Eugenio de; Alonso Carreño, Mónica; Hernández Moreno, Ángel S.; Rodríguez Gómez, Nuria
2007-01-01

Digital.CSIC (Spain)

7

Production of bio-fuels by high temperature pyrolysis of sewage sludge using conventional and microwave heating

Domínguez Padilla, Antonio; Menéndez Díaz, José Ángel; Inguanzo Ojeda, Montserrat; Pis Martínez, José Juan

9 pages, 4 figures, 6 tables.-- PMID: 16473008 [PubMed].-- Printed version published Jul 2006. | The pyrolysis of sewage sludge was investigated using microwave and electrical ovens as the sources of heat, and graphite and char as microwave absorbers. The main objective of this work was to maximize ...

DRIVER (Spanish)

8

Mantle plumes: dynamics and geochemical signature

Cebriá, J. M.; López Ruiz, J.; Doblas, M.
2001-01-01

Digital.CSIC (Spain)

9

La temperatura diurna en la aglomeración de Madrid mediante imágenes remotas

López Gómez, Antonio; Palou, Francisco; Moreno Jiménez, Antonio; Fernández García, Felipe
1990-01-01

Digital.CSIC (Spain)

10

Evaluación de propiedades termodinámicas de mezclas etanol-agua (I)/ Evaluation of thermodynamics properties of ethanol-water mixtures (I)

Pérez Ones, Osney; Díaz Rodríguez, Jorge; Zumalacárregui, Lourdes; Gozá León, Osvaldo
2010-03-01

Resumen en español En este trabajo se presentan modelos y algoritmos para el cálculo de propiedades termodinámicas en mezclas de etanol-agua para diferentes presiones. Esto se logra a través de un método rápido y sencillo con un mínimo de información, partiendo de propiedades que se puedan medir experimentalmente. Los modelos para el cálculo de la entalpía, la capacidad calorífica, el calor latente, la entropía y el coeficiente de actividad se obtienen a partir de consideraciones (mas) termodinámicas y ajustes estadísticos. Los valores de entalpías específicas obtenidas con estas ecuaciones se comparan con los reportados en la literatura, mostrándose la bondad de los ajustes. Resumen en inglés In this work, models and algorithms to estimate thermodynamics properties in ethanol-water mixtures are shown for different pressures. This is achieved through a quick and simple method, requiring minimum information, of measurable properties. Models to estimate enthalpy, heat capacity, latent heat, entropy and activity coefficients models are based on thermodynamics principles and statistic methods. Specific enthalpies values obtained are compared with different literature sources, showing satisfactory adjustments.

Scientific Electronic Library Online (Spanish)

11

Energía solar en el subsuelo

Guinea, Domingo; Peña, P.; Guinea, D. M.; Hernández, O.; Villanueva, E.; Martín, D.; García-Alegre, M. C.
2010-03-01

Digital.CSIC (Spain)

12

Determinación del coeficiente global de transferencia de calor en secaderos rotativos de cáscara de limón/ Determination of global heat transfer coefficient in lemon peel rotary dryers

Golato, Marcos A.; Ruiz, Hugo; D`Angelo, Juan F.; Aso, Gustavo; Paz, Dora
2005-12-01

Resumen en español En la bibliografía consultada no se encontraron trabajos de secado de cáscara de limón en secaderos rotativos. Se realizaron ensayos de medición en secaderos rotativos de cáscara de limón en una instalación agroindustrial del noroeste argentino. Se desarrolló un modelo matemático semiempírico mediante la resolución de los balances de materia y energía. Se obtuvo una correlación estadística para la predicción de los coeficientes globales volumétricos de transferencia de calor aparentes para secaderos rotativos de cáscara de limón. Resumen en inglés No papers on lemon peel drying in rotary dryers were actually found in the sources consulted. Measurement tests were carried out in the assessment of rotary dryer systems used to dehydrate lemon peel in an agroindustrial plant of Northwestern Argentina. A semiempirical mathematic model was developed solving mass and energy balances. A statistical correlation for predicting global heat transfer coefficient in rotary dryer lemon peel dehydration was obtained.

Scientific Electronic Library Online (Spanish)

13

Desarrollo de un Sistema de Secado mediante Lecho Fluido Asistido por Ultrasonidos de Potencia

Fuente, Susana de la; Rodríguez Corral, Germán; Riera, Enrique; Gallego Juárez, Juan Antonio; Mulet Pons, Antonio
2004-09-01

Digital.CSIC (Spain)

14

Degradación atmosférica de un recubrimiento de pintura intumescente

Chico, Belén; López Delgado, Aurora; Lobo Recio, M. A.; Fuente, Daniel de la; Castaño, J. G.; López Gómez, Félix Antonio; Morcillo, Manuel
2004-03-01

Digital.CSIC (Spain)

15

Beta-decay total absorption spectroscopy measurements for reactor decay heat calculations

Taín, José Luis; Algora, Alejandro; Jordán Martín, Mª Dolores
2010-03-29

Digital.CSIC (Spain)