Sample records for PERDIDAS DE CALOR (heat losses)
from WorldWideScience.org

Sample records 1 - 20 shown. Select sample records:



1

Simplificaciones en el Cálculo de Columnas de Destilación Alcohólica/ Simplifications for the Evaluation of Alcoholic Distillation Columns

Pérez, Osney; Zumalacárregui, Lourdes; Gozá, Osvaldo
2010-01-01

Resumen en español Se analiza el efecto de algunas simplificaciones en cálculos de columnas de destilación alcohólica, tales como considerar solo etanol y agua en las corrientes involucradas en el proceso y suponer que las pérdidas de calor al medio ambiente son despreciables. Se discute el efecto de la reducción de la cantidad de componentes en el vino, sobre la entalpia de las corrientes de la columna, desde un sistema de nueve componentes hasta el sistema binario etanol+agua. Se uti (mas) lizan tres modelos de evaluación de propiedades demostrando que los resultados no se afectan de manera sensible. Se estimaron las pérdidas de calor al medio ambiente por convección y radiación, tanto en una columna rectificadora como en una repasadora, aisladas térmicamente y sin aislamiento. Se demuestra la validez de las consideraciones utilizando el simulador de procesos HYSYS Resumen en inglés The effect of certain simplifications in calculations of alcoholic distillation columns, such as to consider ethanol and water as the only components and to neglect heat losses is analyzed. The effect of reducing the number of components in the wine, from nine to the binary ethanol+water, over the enthalpy of the streams is discussed. The analysis was done from a nine components solution to the binary system ethanol-water. Three models for estimating the required properti (mas) es were used showing that results are not significantly affected. The effects of heat losses by convection and radiation were estimated on both rectifying and purifying columns for insulated and non insulated cases were evaluated. The paper shows that the simplifications introduced to the HYSYS simulator are correct

Scientific Electronic Library Online (Spanish)

2

Modelo de simulación para estimar el balance calórico de bovinos en pastoreo

Mendoza Martínez, Germán D; Pinos Rodríguez, Juan M; Ricalde Velasco, Raúl; Aranda Ibáñez, Emilio M; Rojo Rubio, Rolando
2003-04-01

Resumen en portugués Desenvolveu-se um modelo determinístico para estimar o intercambio calórico de bovinos no pastoreio em temperaturas maiores à mínima temperatura crítica. Os componentes do modelo incluíram calor metabólico (CM), evaporação (CE), convecção (CV), condução (CD) e radiação. O CM se estimou a partir do consumo de energia metabolizável, pela excreção de uréia e a desaminação da proteína não depositada. As perdas respiratórias foram calculadas com base na (mas) pressão de saturação do vapor do ar inspirado e expirado. O volume respiratório foi estimado com base na temperatura ambiental (TA) e umidade relativa (HR). Considerou-se que as perdas pela pele eram proporcionais às respiratórias em função da TA. As perdas por CV foram calculadas assumindo uma forma cilíndrica do animal, em função da TA e velocidade do vento. As perdas de calor por CD para o solo foram calculadas de acordo ao tempo de pastoreio e de descanso em função à TA e HR. A radiação foi estimada pelas horas luz com uma constante solar de 1200kcal/h/m2/animal/d A principal fonte de ganho de calor foi a radiação (60-70%) seguida pelo calor metabólico (29-39%) com um mínimo ganho por excreção de uréia e desaminação (1%). A principal forma para dissipar o calor foi a evaporação (60%). O calor re-irradiado representou uma dissipação de 30% enquanto que por CV se dissipou o 2%, e 5% por CD. O modelo permite predizer mudanças no intercambio calórico sob diversas condições ambientais. Resumen en español Se desarrolló un modelo determinístico para estimar el intercambio calórico de bovinos en pastoreo en temperaturas mayores a la mínima temperatura crítica. Los componentes del modelo incluyeron calor metabólico (CM), evaporación (CE), convección (CV), conducción (CD) y radiación. El CM se estimó a partir del consumo de energía metabolizable, por la excreción de urea y la desaminación de la proteína no depositada. Las pérdidas respiratorias fueron calculada (mas) s en base a la presión de saturación del vapor del aire inspirado y expirado. El volumen respiratorio fue estimado en base a la temperatura ambiental (TA) y humedad relativa (HR). Se consideró que las pérdidas por piel eran proporcionales a las respiratorias en función de la TA. Las pérdidas por CV fueron calculadas asumiendo una forma cilíndrica del animal, en función de la TA y velocidad del viento. Las pérdidas de calor por CD hacia el piso fueron calculadas de acuerdo al tiempo de pastoreo y de descanso en función a la TA y HR. La radiación fue estimada por las horas luz con una constante solar de 1200kcal/h/m2/animal/d La principal fuente de ganancia de calor fue la radiación (60-70%) seguida por el calor metabólico (29-39%) con una mínima ganancia por excreción de urea y desaminacion (1%). La principal forma para disipar el calor fue la evaporación (60%). El calor re-irradiado representó una disipación del 30% mientras que por CV se disipó el 2%, y 5% por CD. El modelo permite predecir cambios en el intercambio calórico bajo diversas condiciones ambientales. Resumen en inglés A deterministic simulation model was developed to estimate heat exchange in cattle grazing in climates with temperatures over the minimum critical temperature. The model included metabolic heat (MH), evaporation heat loss (EHL), convection (CV), conduction (CD) and radiation. The MH was estimated from metabolizable energy intake, urea excretion and protein deamination. Respiratory heat losses (RHL) were estimated from saturation vapor pressure at body temperature and from (mas) inspired and expired air. Respiratory volume was obtained from ambient temperature (AT) and relative humidity (RH). It was assumed that skin latent heat loss is proportional to with RHL depending on ambient temperature. CH loss were calculated assuming a cylindrical shape of the animal as a function of AT and air velocity. CD heat loss to the floor was estimated according to grazing and resting time depending on AT and RH. Thermal radiant exchange was estimated with the solar constant (1200kcal/h/m2/animal/d). The main heat gain was by radiation (60-70%) followed by MH (29-39%), being minimum the heat associated to nitrogen metabolism (1%). The main mechanism to dissipate heat was by evaporation (60%). Re-irradiated heat contributed with 30% dissipation, whereas CV contributed 2% and CD 5%. The heat balance model can predict heat exchange response under different environmental conditions.

Scientific Electronic Library Online (Spanish)

3

Caracterización de las propiedades del aire húmedo (Sicrometría) del microclima de la hacienda Vegas de la Clara (nordeste antioqueño, Colombia)/ Determination of the states of the humid air (psychrometric) of the microclimate of the Vegas de la Clara farm (nordeste antioqueño, Colombia)

Estrada-Pareja, Mónica M; Márquez-Girón, Sara M; Restrepo-Betancur, Luis F
2007-09-01

Resumen en español Mediante un análisis estadístico descriptivo exploratorio se determinaron las características del aire húmedo (Sicrometría) del microclima de la hacienda Vegas de la Clara (nordeste antioqueño), para lo cual se midieron la presión atmosférica (910.41 kg/cm²), la temperatura ambiente (25 ± 3.264οC), y la humedad relativa (75.4 ± 11.9%), en diferentes momentos del año (periodos de lluvia, época de transición y periodo seco). A partir de los resultados (mas) se construyó la carta Sicrométrica como herramienta para el estudio posterior sobre las pérdidas de calor de los pollos en la etapa de finalización del periodo productivo (publicada en otro artículo de este mismo volumen). Resumen en inglés An exploratory descriptive statistical analysis was applied for determining the characteristics of the humid air (Sicrometría) of the microclimate of Vegas de la Clara farm (northeast antioqueño) were determined, for which the atmospheric pressure (910.41 kg/cm2), ambient temperature (25 ± 3.264ºC), and relative humidity (75.4 ± 11.97%) were measured, at different times of the year (rainy, transition time and dry periods). From these results a psychrometric chart was (mas) constructed and used as a tool for an experimental study focused on the estimation of heat losses in broilers during its finishing period reported elsewhere.

Scientific Electronic Library Online (Spanish)

4

Selección de Turbinas de Gas para Sistemas de Trigeneración/ Gas Turbine Selection for Trigeneration Systems

Picón, M; Teopa, E; Gallegos, A
2005-01-01

Resumen en español En este trabajo se presenta una metodología para el análisis y selección de turbinas de gas en sistemas de trigeneración. Se desarrolla un modelo termodinámico para reproducir el desempeño de turbinas de gas comerciales en condiciones ISO y en las condiciones locales donde se opera. El modelo incluye el análisis de sistemas de refrigeración por compresión. Se desarrolla un caso de estudio donde se realiza la integración térmica del sistema de trigeneración uti (mas) lizando los conceptos básicos del análisis pinch. Una vez integrada la turbina se analiza la operación bajo diferentes escenarios de producción de calor y potencia. Se demuestra que el sistema integrado más eficiente es aquel que proporciona la potencia requerida por el proceso y que minimiza las pérdidas al ambiente Resumen en inglés This work presents a methodology for the analysis and selection of gas turbines in trigeneration systems. A mathematical model was developed for the prediction of the performance of gas turbines under ISO conditions and under the local conditions of turbine operation. The model included the analysis of refrigeration systems by compression. A case study was carried out where a gas turbine was thermally integrated using pinch analysis techniques. The performance of the inte (mas) grated turbine under different scenarios of heat production and power was analyzed. It was demonstrated that the most efficient integrated system was the one that both supplied the process power requirement and minimized the heat losses to the environment

Scientific Electronic Library Online (Spanish)

5

Obtención del Valor Real de las Pérdidas de Difícil Evaluación, Aplicables al Cálculo del Rendimiento de Calderas/ Obtaining the Real Value of Difficult-Evaluation Heat Losses, Applied to the Calculation of Boiler Efficiency

Blanco, Jesús M; Peña, Francisco
2006-01-01

Resumen en español Se presenta un estudio para la obtención del valor real de las pérdidas de difícil evaluación aplicables al cálculo del rendimiento de calderas. A las pérdidas de difícil evaluación se les adjudicó un valor convencional del 1 % sobre el poder calorífico superior del combustible utilizado. El método propuesto permite determinar con exactitud dichas pérdidas y está indicado para cualquier tipo de combustible. Para el estudio, se han seleccionado el gas natural (mas) y el fuel-oil (fuel nº 2 y fuel de bajo índice de azufre respectivamente). El valor convencional del 1% sobre el poder calorífico superior ha sido muy útil para la comparación de rendimientos en calderas como se muestra en este trabajo Resumen en inglés A study to obtain the real value of difficult-evaluation heat losses applied to the calculation of boiler efficiency is presented. A conventional value of 1 % over the gross caloric value of the fuel was assigned to each fuel. The proposed method allows to accurately determining these losses and is suitable for any type of fuel. For the study, both natural gas and fuel-oils (number2 and low sulphur content fuel respectively) were selected. The conventional value of 1% over the gross caloric value has been useful to compare boiler efficiency as demonstrated in this work

Scientific Electronic Library Online (Spanish)

7

Water stress preconditioning to improve drought resistance in young apricot plants

Ruiz Sánchez, Mª Carmen; Domingo Miguel, Rafael; Torrecillas Melendreras, Arturo; Pérez-Pastor, A.
2000-07-28

Digital.CSIC (Spain)

8

Vitamin C, Provitamin A Carotenoids, and Other Carotenoids in High-Pressurized Orange Juice during Refrigerated Storage

Sánchez-Moreno, Concepción; Plaza, Lucía; Ancos, Begoña de; Cano, M. Pilar
2003-01-01

Digital.CSIC (Spain)

9

Using sap flow measurements to quantify water consumption in apricot trees

Nicolás Nicolás, Emilio; Torrecillas Melendreras, Arturo; Alarcón Cabañero, Juan José
2006-09-30

Digital.CSIC (Spain)

10

Thermal conductance measurements of superconducting bi-2212 rods and a bi-2212-based current leadmodule

Natividad, Eva; Castro, Miguel; Burriel, Ramón; Angurel Lambán, Luis Alberto
2006-05-01

Digital.CSIC (Spain)

12

Temporal variability of the anthropogenic CO2 storage in the Irminger Sea

Fernández Pérez, Fíz; Vázquez Rodríguez, Marcos; Louarn, E.; Padín, X. Antonio; Mercier, Herlé; Ríos, Aida F.
2008-12-11

Digital.CSIC (Spain)

13

Selective activation of the developmentally regulated Ha hsp17.6 G1 promoter by heat stress transcription factors

Rojas, Anabel; Almoguera, Concepción; Carranco, Raúl; Klaus-Dieter, Scharf; Jordano, Juan
2002-06-14

Digital.CSIC (Spain)

14

Selección Económica de Cables Teniendo en Cuenta las Pérdidas Térmicas/ Selection of Cable Economy Taking Thermal Losses into Consideration

Toraño, J; Rodríguez, R; Diego, I; López, L.M.
2004-01-01

Resumen en español El objetivo de este artículo es determinar las bases que, de manera simplificada, sirvan de guía para saber cuando es recomendable hacer un análisis económico de una instalación eléctrica teniendo en cuenta las pérdidas térmicas. Ayudándose de una aplicación de software desarrollada para tal fin, se han llevado a cabo un gran número de simulaciones representativas de instalaciones industriales. En cada simulación se partió de la sección obtenida por el cálc (mas) ulo según los tres criterios básicos (caída de voltaje, amperaje y condiciones de cortocircuito) se fue aumentando la sección de cable y se determinó el coste de capital que conllevaba dicho aumento de sección. Por último, dicho coste se comparó con el coste operativo por pérdidas térmicas al utilizar el cable inicial de menor sección. Del estudio se concluye que para potencias medias (aproximadamente 700-800 kW con 4180 V o 75-300 kW con 480 V) dicho análisis económico es muy recomendable Resumen en inglés The objective of this study was to determine as simply as possible the criteria that can serve as a guide for determining when an economic analysis of an electrical installation considering heat losses is required. A large number of simulations representative of industrial installations were carried out using computer software specifically designed for this purpose. Each simulation was begun with a section obtained from calculations made from three basic criteria (voltage (mas) drop, current, and short circuit conditions) and then increasing the cable section to determine the increase of the capital cost caused by the increase in the cable section. Finally, this cost was compared with operational cost due to thermal losses when using the initial cable which was smaller in section. It is concluded from the study that for moderate power (approx. 700-2800 kW in 4180 V or 75-300 kW in 480 V) economic analysis is highly recommended

Scientific Electronic Library Online (Spanish)

15

Sap flow as an indicator of transpiration and the water status of young apricot trees

Alarcón Cabañero, Juan José; Domingo Miguel, Rafael; Green, S. R.; Sánchez-Blanco, María Jesús; Rodríguez, Pedro
2000-01-01

Digital.CSIC (Spain)

16

Nucleación y crecimiento de la fase perovskita en láminas delgadas de Pb0.88La0.08TiO3

Algueró Giménez, Miguel; Calzada Coco, María Lourdes; Pardo Mata, Lorena; Quintana, C.
1998-06-01

Digital.CSIC (Spain)

17

Monitoring land degradation risk using ASTER data: The non-evaporative fraction as an indicator of ecosystem function

García García, Mónica; Oyonarte, Cecilio; Villagarcía, Luis; Contreras, Sergio; Domingo, Francisco; Puigdefábregas, Juan
2008-07-25

Digital.CSIC (Spain)

18

Mineralogical characterization of silica sinters from the El Tatio geothermal field, Chile

García-Vallés, M.; Fernandez-Turiel, J. L.; Gimeno, D.; Saavedra Alonso, Julio; Martínez-Manent, S.
2008-01-01

Digital.CSIC (Spain)

19

Melanin-based color variation in the Bearded Vulture suggests a thermoregulatory function

Margalida, Antoni; Negro Balmaseda, Juan José; Galván, Ismael
2008-11-07

Digital.CSIC (Spain)

20

Mantle plumes: dynamics and geochemical signature

Cebriá, J. M.; López Ruiz, J.; Doblas, M.
2001-01-01

Digital.CSIC (Spain)

21

Loss of function of the HSFA9 seed longevity program

Tejedor-Cano, J.; Prieto-Dapena, P.; Almoguera, Concepción; Carranco, R.; Hiratsu, K; Ohme-Takagi, M.; Jordano, Juan
2010-04-22

Digital.CSIC (Spain)

22

Interaction of Mediterranean water eddies with Sedlo and Seine Seamounts, Subtropical Northeast Atlantic

Bashmachnikov, Igor; Mohn, Christian; Pelegrí, Josep Lluís; Martins, Ana María; Jose, Felix; Machín, Francisco; White, Martin
2009-12-01

Digital.CSIC (Spain)

24

Influence of dimethylpolysiloxane addition to edible oils: dependence on the main variables of the frying process

Jorge, Neuza; Márquez Ruiz, Gloria; Martín-Polvillo, M.; Ruiz Méndez, M.ª Victoria; Dobarganes, M.ª Carmen
1996-04-30

Digital.CSIC (Spain)

25

Gold nanoparticles for selective and remote heating of β-amyloid protein aggregates

Gómez Bastus, Neus; Kogan, Marcelo J.; Amigo, Roger; Grillo-Bosch, Dolors; Araya, Eyleen; Turiel, Antonio; Labarta, Amilcar; Giralt, Ernest; Puntes, Victor F.
2007-09-01

Digital.CSIC (Spain)

26

Espumado por microondas de mezclas de silicato de sodio-ortofosfato cálcico dibásico

Vargas Gutiérrez, G.; Méndez Nonell, J.; Pena Castro, María del Pilar; Pérez, J. C.; Méndez, M.
2002-09-01

Digital.CSIC (Spain)

27

Electronic state characterization of SiOx thin films prepared by evaporation

Barranco Quero, Ángel; Yubero Valencia, Francisco; Espinós Manzorro, Juan Pedro; Groening, P.; González-Elipe, Agustín R.
2005-06-08

Digital.CSIC (Spain)

28

Effects of water stress and night temperature preconditioning on water relations and morphological and anatomical changes of Lotus creticus plants

Bañón, Sebastián; Fernández, J. A.; Franco, J. A.; Torrecillas Melendreras, Arturo; Alarcón Cabañero, Juan José; Sánchez-Blanco, María Jesús
2004-09-10

Digital.CSIC (Spain)

29

Effect of Temperature on the Free Radical Scavenging Capacity of Extracts from Red and White Grape Pomace Peels

Larrauri, José A.; Sánchez-Moreno, Concepción; Saura Calixto, Fulgencio D.
1998-07-01

Digital.CSIC (Spain)

30

Efecto de los cambios microclimáticos sobre la fisiología del maíz durante el riego por aspersión

Martínez-Cob, Antonio; Cavero Campo, José; Aibar, Joaquín; Puig Basa, Miriam
2007-11-01

Digital.CSIC (Spain)

31

Efecto de la temperatura y la humedad relativa en los parámetros productivos y la transferencia de calor en pollos de engorde/ Effect of temperature and relative humidity on the productive behaviour and the transfer of heat in broilers

Estrada-Pareja, Mónica M; Márquez-Girón, Sara M; Restrepo Betancur, Luis F
2007-09-01

Resumen en español Para lograr máximos rendimientos productivos en las explotaciones de pollo de engorde, es imprescindible manejar un entorno adecuado que les proporcione a las aves las condiciones ambientales óptimas. En este trabajo se evaluó el efecto de la temperatura y la humedad relativa en la respuesta productiva y transferencia de calor en pollos de engorde, con el propósito de establecer la zona termo-neutral en el microclima de la hacienda Vegas de la Clara (nordeste antioque (mas) ño, Colombia), para optimizar los modelos de producción. En la primera parte del trabajo, se determinó, mediante un análisis estadístico descriptivo exploratorio el comportamiento térmico de los pollos de la línea Ross en la etapa de cría, midiendo los cambios de temperatura corporal desde el nacimiento (heterotermos con temperatura corporal de 39.741 ± 0.44 ºC), hasta que alcanzaron la condición de endotermos (temperatura corporal: 40.37 ± 0.221 ºC); al finalizar ésta etapa fue determinada la homogeneidad del lote, en cuanto a pesos corporales, con el propósito de obtener uniformidad en las unidades experimentales (pollos) para llevar a cabo la fase experimental correspondiente a la etapa final del periodo productivo. En la fase experimental, se evaluó los efectos de tres diferentes temperaturas (19, 25, y 31 ºC) a una humedad relativa del 75% en la transferencia de calor y en el rendimiento productivo, por medio de consumo de alimento, peso corporal, conversión alimenticia y morbi – mortalidad. Mediante la aplicación de la técnica de MANOVA con contrastes canónicos y un diseño de estructuras completamente aleatorizado se determinó que el mejor comportamiento productivo para el peso corporal y la conversión alimenticia se obtuvo a una temperatura de 19 ºC (p0.05). Resumen en inglés To achieve maximum productive yields in broiler production, it is indispensable to manage an appropriate environment that provides to the birds the good environmental conditions. In this work the effect of temperature and relative humidity in the productive performance and transfer of heat in broilers was evaluated, with the purpose of establishing the thermal comfort zone in the microclimate of Vegas de la Clara farm (Nordeste antioqueño, Colombia), to optimize the prod (mas) uction models. In the first part of the work, the behaviour of breed Ross chickens in the breeding stage was determined by means of an exploratory descriptive statistical analysis, measuring changes of corporal temperature from birth (heterothermos with (corporal temperature of 39.741 ± 0.44 ºC), until the chickens reached the endothermos condition (corporal temperature of 40.37 ± 0.221 ºC); when concluding this stage the homogeneity of the lot was determined, concerning body weight, with the purpose of obtaining uniformity in the experimental units (chickens) to carry out the experimental phase corresponding to the final stage of the productive period. In the experimental phase, the influence of three different temperatures (19, 25 and 31 ºC) with a constant relative humidity of 75% on heat transfer and broiler productive yield as measured by food consumption, body weight, nutritional conversion and morbi–mortality, was evaluated. The results were evaluated by MANOVA with canonical contrasts and a totally randomized design of structures. The best productive behaviour to body weight and nutritional conversion was obtained at a temperature of 19 ºC when compared to the other treatments (p0.05).

Scientific Electronic Library Online (Spanish)

32

EVALUACIÓN DE LAS PÉRDIDAS TÉRMICAS EN CALORIMETRÍA ISOPERIBÓLICA. IMPORTANCIA DE LOS ALREDEDORES EN LA OBTENCIÓN DE CONSTANTES INSTRUMENTALES/ EVALUATION OF THE THERMAL LEAKAGE IN ISOPERIBOLIC CALORIMETRY. IMPORTANCE OF THE ENVIRONS IN THE OBTAINING OF INSTRUMENTAL CONSTANTS

Giraldo G, Liliana; Cubillos, Gloria Ivonne; Moreno P, Juan Carlos
2005-12-01

Resumen en español Para tres unidades calorimétricas con aislamientos en PVC, nailon y metálico se determina la constante de fugas térmicas, K, con valores de 6,50 x 10-3, 6,37 x 10-5 y 2,52 x 10-4 s-1, respectivamente. Se determina la capacidad calorífica del sistema con agua para cada una de las unidades calorimétricas y se obtienen valores para esta constante de 442,1 J °C-1 para la celda con aislamiento en PVC, 206,7 J °C-1 para la celda con aislamiento de nailon y 408,2 J °C-1 (mas) para la celda con aislamiento metálico. Se establece la influencia de la magnitud del efecto térmico en las pérdidas térmicas y en la constante de fugas térmicas, para trabajos eléctricos entre 0,5 y 3,4 kJ. Se determina la entalpía de solución para el sistema propanol-agua, con resultados similares para las tres unidades calorimétricas del orden de 10,7 kJmol-1 . Resumen en inglés For three calorimetric units with isolations in PVC, nylon and metal, the heat leakage constant, K, is determined, giving values of 6.50 x10-3, 6.37 x10-5 and 2.52 x 10-4 s-1 respectively. The heat capacity of the system with water for each one of the calorimetric units was determined and values obtained for this constant are of 442.1 JC-1 for the cell with insulation in PVC, 206.7 JC-1 for the cell with insulation of nylon and 408.2 JC-1 for the cell with metallic insula (mas) tion. The influence of the thermal effect magnitude in the thermal losses and the heat leakage constant, for electrical works between 0.5 and 3.4 kJ is established. Solution enthalpy for the system propanol- water was determined, with similar results for the three calorimetric units of the order of 10.7 kJmol-1.

Scientific Electronic Library Online (Spanish)

33

Costumed of scale inhibitors in oilfield water plant

León, Orietta; Cárdenas, Carmen; Carruyo, Jenny
2002-04-01

Resumen en español El objetivo de este trabajo fue acondicionar el tratamiento químico de inhibidores de incrustación de una planta de aguas de deshidratación del petróleo. En esta agua debe cumplirse que la dureza total a la entrada sea igual a la dureza total de la salida de la planta, para evitar que el depósito de incrustaciones ocasionen: diferimiento de la Producción, problemas con la inyección de agua, disminución de la transferencia de calor, restricción en el flujo (pérdi (mas) das de presión), corrosión por celdas de concentración, trabajos de reacondicionamiento de pozos debido a reducción en la producción, reparación y mantenimiento de los equipos de superficie, consumo de aditivos químicos para la limpieza de los equipos incrustados. Se caracterizó el agua de deshidratación del petróleo que entra a la Planta de Tratamiento resultando incrustante; por lo que se evaluaron diferentes inhibidores de incrustaciones en el laboratorio. Los inhibidores de incrustación fueron divididos para su mejor estudio según su materia activa en: poliacrilatos, fosfonatos, polifosfonatos y mezclas de fosfonatos-poliacrilatos Los inhibidores de incrustación a base de poliacrilato, de polifosfonatos y de mezcla de poliacrilatos y fosfonato, obtuvieron un 100% de eficiencia en el laboratorio. Resumen en inglés The purpose of this work was to condition the chemical treatment, scale inhibitors, of a plant of dehydration of oilfield water. This water must fulfill the condition that the total hardness at the entry will be equal to the total hardness at the exit of the plant, to avoid the scale formation to cause: deferred Production, problems with the water injection, decrease in the heat transference, restriction in the flow (losses of pressure), corrosion by concentration cells, (mas) works of re-conditioning of wells due to production reduction, repairing and maintenance of the surface equipment, chemical additives consumption for cleanlining incrusted equipment. The analysis perfomed demonstrated that the water was scale forming, At the laboratory, several scale inhibitors was evaluated. The scale inhibitors were divided for its study according to its active matter in: polyacrilates, fosfonates, polyfosfonates and a mixture of fosfonates and polyacrilates The scale inhibitors based on polyacrilate, polyfosfonate and a mixture of polyacrilate-fosfonate, obtained a 100% of efficiency in the laboratory for different concentrations.

Scientific Electronic Library Online (Spanish)

34

Contribution of histones H2A and H2B to the folding of nucleosomal DNA

Jordano, Juan; Montero, F.; Palacián, Enrique
1984-01-01

Digital.CSIC (Spain)

35

Contribution of Evapotranspiration Reduction during Sprinkler Irrigation to Application Efficiency

Martínez-Cob, Antonio; Playán Jubillar, Enrique; Zapata Ruiz, Nery; Cavero Campo, José; Medina Pueyo, Eva Teresa; Puig Basa, Miriam
2008-12-01

Digital.CSIC (Spain)

36

Comparison of hydrocarbon gases (C1–C5) production from Carboniferous Donets (Ukraine) and Cretaceous Sabinas (Mexico) coals

Alsaab, D.; Elie, M.; Izart, A.; Sachsenhoferb, R. F.; Privalov, V. A.; Suárez Ruiz, Isabel; Martínez, L.
2008-04-03

Digital.CSIC (Spain)

38

Clean and efficient use of petroleum coke for combustion and power generation

Wang, Jinsheng; Anthony, Edward J.; Abanades García, Juan Carlos
2004-01-22

Digital.CSIC (Spain)

39

Characteristics of high heating rate biomass chars prepared under N2 and CO2 atmospheres

Gómez Borrego, Ángeles; Garavaglia, L.; Kalkreuth, W. D.
2009-01-31

Digital.CSIC (Spain)

40

Cambio microclimático y pérdidas por evaporación y arrastre en riego por aspersión en maíz

Martínez-Cob, Antonio; Aibar, Joaquín; Medina Pueyo, Eva Teresa
2006-05-01

Digital.CSIC (Spain)

41

Ant-nest corrosion of copper tubing in air-conditioning units

Bastidas, D. M.; Cayuela, I.; Bastidas Rull, José María
2006-09-30

Digital.CSIC (Spain)

42

Ant-nest corrosion of copper tubing in air-conditioning

Martínez Bastidas, David; Cayuela, I.; Bastidas Rull, José María
2006-10-30

Digital.CSIC (Spain)