Sample records for CORROSION GALVANICA (galvanic corrosion)
from WorldWideScience.org

Sample records 1 - 10 shown.



1

Evaluación de la corrosión galvánica en amalgamas dentales de alto contenido de cobre por medio de técnicas electroquímicas/ Evaluation of the galvanic corrosion of high copper dental amalgams by means of electrochemical techniques

Castaño Rivera, Patricia; Echavarría Velásquez, Alejandro; Gómez, Gabriel Jaime; Arismendi, Jorge
2008-09-01

Resumen en español En este trabajo se evaluó la corrosión galvánica de tres amalgamas dentales de alto contenido de cobre, una nacional Nu Alloy®dp (New Stetic) y dos importadas Contour®TM (Kerr, USA) y GS-80® (SDI, Australia), interactuando galvánicamente y en un diseño in Vitro con los siguientes materiales metálicos de uso odontológico: Titanio CP, Ti-6Al-4V tipo COC®, IPS d.sign 15 (Ni-Cr-Mo) e IPS d.sign 91® (Au-Pd). Con la técnica electroquímica Amperometría de resisten (mas) cia cero, se midió la evolución de las corrientes galvánicas en el tiempo. También se elaboraron curvas de polarización cíclicas para caracterizar electroquímicamente las amalgamas dentales y medidas del potencial a circuito abierto para analizar la nobleza o actividad de ellas en el medio de estudio. Los ensayos se realizaron por triplicado, en una celda de tres electrodos y utilizando como electrólito la solución fisiológica artificial de Ringer, desaireada y a 37 ± 1°C. De los resultados, se concluyó que en comparación a las amalgamas importadas, la amalgama nacional tiene la misma tendencia a sufrir corrosión galvánica bajo las condiciones de ensayo. Con el método estadístico ANOVA de una sola vía, se comprobó la similitud en el comportamiento electroquímico de las tres amalgamas dentales. Resumen en inglés The galvanic interaction between three high copper dental amalgams with another four dental metallic materials, was evaluated. The dental amalgams were: a national Nu Alloy®dp (New Stetic) and two imported Contour®TM (Kerr, USA) and GS-80® (SDI, Australia). The dental metallic materials were: Titanium CP, Ti-6Al-4V type COC®, IPS d.sign 15® (Ni-Cr-Mo) and IPS d.sign 91® (Au-Pd). The evolution of the galvanic currents with time was measured using a Zero Resistance Am (mas) meter equipment. The dental amalgams were characterized by means of Polarization Cyclical Measurements, and the evolution of the open circuit potentials of the dental amalgams allowed analyzing the nobility or activity of the amalgams in the test mean. The tests were done by triplicate in a three electrode cell and using the artificial physiological solution of Ringer as the electrolyte, the solution was deaerated at 37 ±1°C. Under the test conditions, it is concluded that the home amalgam has the same tendency to undergo galvanic corrosion as comparison to imported amalgams. Using statistical ANOVA method of a single via it was corroborated the same electrochemical behavior of dental amalgams.

Scientific Electronic Library Online (Spanish)

2

Acción galvánica superficial en una matriz de acero al carbono constituida por microceldas con granos de ferrita y perlita/ Surface galvanic action on a carbon steel matrix microcell consisting on ferrite and pearlite grains

León-Bello, F.; Amaya-Malpica, M. G.
2008-04-01

Resumen en español Con el propósito de dilucidar los parámetros de ingeniería que cuantifiquen el efecto de las reacciones electroquímicas de corrosión en el acero al carbono, se propone un modelo termodinámico irreversible para estimar la acción galvánica en una matriz heterogénea y policristalina, formada por granos de ferrita y perlita. El modelo considera un sistema abierto que representa la superficie de la matriz metálica y el electrolito. La acción galvánica a escala micr (mas) oscópica se describe mediante un sistema de ecuaciones que reúne los efectos de la difusión térmica, la codifusión debida a un gradiente de potencial químico y las contribuciones a la producción de entropía debidas al flujo de calor y a la corriente de difusión. La aplicación del modelo requiere validarse con experimentos en los que se obtengan valores adecuados de los coeficientes fenomenológicos. La naturaleza heterogénea del arreglo de los granos en la superficie del acero, corresponde con un mecanismo heterogéneo de la acción galvánica, por lo que los parámetros de ingeniería resultado del análisis son valores medios de las magnitudes de las propiedades extensivas del sistema. Resumen en inglés An irreversible thermodynamics model is proposed to estimate galvanic action on a heterogeneous polycrystalline matrix, made on ferrite and pearlite grains, in order to find engineering parameters to account for the effect of electrochemical reactions due to corrosion processes on carbon steel. The model is based on an open system representing the surface of the metallic matrix and the electrolyte. The galvanic action at microscopic scale is described by a system of equat (mas) ions that meets thermal diffusion and chemical co diffusion effects with entropy production due to both heat and diffusion fluxes. The application of the model requires an experimental validation on which adequate values for the phenomenological coefficients were found. The heterogeneous nature of the grains arrangement on the carbon steel surface corresponds to a heterogeneous mechanism of galvanic action so that the resulting engineering parameters are mean values of the magnitude on the extensive properties of the system.

Scientific Electronic Library Online (Spanish)

3

Protesis parcial fija por la técnica de electrodeposición con oro: relato de caso clínico

Nishioka, Renato Sussumu; Kojima, Alberto Noriyuki; Vásquez, Vanessa Zulema Ccahuana
2007-09-01

Resumen en español Resumen Electrodeposición es la deposición galvánica de la aleación de oro con 99% de pureza (24K) para el uso odontológico, teniendo como principio la electrólisis. Este sistema de electrodeposición permite la confeción de una cofia de oro con una excelente adaptación marginal. Puede ser fabricado con un espesor mínimo de 0,2mm haciendo posible realizar un desgaste menor en la preparación de pilares, y sobre esa fina infraestructura se puede aplicar una capa m (mas) ayor de cerámica optimizando la estética cuando se compara con la fundición de estructuras convencionales. Hace posible la confección de coronas y prótesis parciales fijas. Las coronas metal-cerámicas confeccionadas por la técnica de electrodeposición otorgan una estética satisfactoria, debido a una apariencia mas natural y mejor calidad del color. Adicionalmente presenta características ventajosas como ausencia de corrosión y una excelente biocompatibilidad con los tejidos periodontales.  Este trabajo muestra la confección de coronas metalocerámicas totales hechas con cofias por electrodeposición, teniendo como objetivo presentar una alternativa  en prótesis parcial fija para los profesionales Resumen en inglés SUMMARY Electrodeposition is the galvanic deposition of the gold alloy with 99% of purity (24K) for the dentistry use, having like principle electrolysis. This electrodeposition system allows the preparation of pure gold coping with an excellent marginal fit. It can be made with a minimum thickness of 0,2mm doing possible to make a less teeth reduction, and on that fine infrastructure can be applied to a greater layer of ceramics optimizing the aesthetic when it is compar (mas) ed with the cast conventional copings. It is possible the preparation of unitary and fixed partial prostheses. The metal-ceramics crowns made by the electrodeposition technique present an aesthetic satisfactory, due to a natural appearance and better quality of the color. Additionally, it presents advantageous characteristics as corrosion absence and an excellent biocompatibility with periodontal tissues. This work shows the preparation of complete metal-ceramics crowns made with copings by electrodeposition, having as objective present an alternative in fixed partial prosthetics for the professionals

Scientific Electronic Library Online (Spanish)

4

Sistema y método de evaluación de la protección anticorrosiva de recubrimientos orgánicos

Suay Antón, Julio; García Espallargas, Santiago Juan; Gracenea Zapirain, José Javier; Galván Sierra, Juan Carlos
2010-01-08

Digital.CSIC (Spain)

5

Recubrimiento sol-gel con nanopartículas de titania para la protección de un sustrato y procedimiento para su obtención.

Sánchez Majado, Sagrario; Jiménez Morales, Antonia; Torralba Castelló, José Manuel; Galván Sierra, Juan Carlos
2010-03-11

Digital.CSIC (Spain)

6

Recubrimiento sol-gel con nanopartículas cerámicas para la protección de un sustrato y procedimiento para su obtención

Sánchez Majado, Sagrario; Jiménez Morales, Antonia; Torralba Castelló, José Manuel; Galván Sierra, Juan Carlos
2010-03-11

Digital.CSIC (Spain)