Sample records for INESTABILIDAD DE DERIVA (drift instability)
from WorldWideScience.org

Sample records 1 - 4 shown.



1

Derrumbe del liceo RMC durante el terremoto de Cariaco de 1.997/ Collapse of rmc high-school during the 1997 cariaco earthquake

López, Oscar A; Espinosa, Luis F
2007-07-01

Resumen en español Numerosas escuelas se han derrumbado o dañado en el mundo durante la ocurrencia de terremotos, acabando con la vida de niños y maestros. Venezuela no ha escapado a esta situación y ejemplo de ello fue lo ocurrido en 1.997 en el Estado Sucre cuando un sismo de magnitud Ms=6,8 ocasionó el derrumbe de cuatro edificios escolares, dos de ellas pertenecientes al Liceo Raimundo Martínez Centeno. La falla de la estructura se caracterizó por el colapso de su planta baja, que (mas) dando la losa del primer piso apoyada directamente sobre el suelo. En este trabajo se utilizan técnicas de análisis dinámico no-lineal, basadas en la concentración de daños en secciones críticas de la estructura, a fin de identificar las causas del derrumbe. La presencia de las paredes y de la escalera influencian significativamente las propiedades dinámicas del edificio reduciendo los períodos de vibración. Los valores definidos en este trabajo como derivas de cedencia y derivas últimas de entrepiso a partir de un análisis estático no-lineal resultaron ser buenos estimadores del umbral del daño y del umbral del colapso durante la respuesta dinámica no-lineal, respectivamente. La respuesta dinámica no-lineal ante acelerogramas representativos del movimiento sísmico se caracteriza por una concentración de deformación en el primer entrepiso (planta baja) que excede las derivas tolerables; la inestabilidad se inicia en los pórticos centrales con la falla frágil por cortante de las columnas muy cortas del primer entrepiso, creadas por la presencia de paredes de mampostería adosadas a las columnas y con pequeñas aberturas en la parte superior. El modo den falla resultante de los análisis es congruente con lo observado en sitio. Removiendo las paredes y repitiendo los análisis se observa también una concentración de deformaciones en el primer entrepiso que conduce a la inestabilidad del edificio. El derrumbe de ambos edificios del Liceo puede ser atribuido a la limitada capacidad para resistir carga lateral y para disipar energía, aunado a la presencia de columnas cortas que precipitaron los modos de falla frágil de la estructura, que son características de las edificaciones construidas con las normas antiguas de diseño sismorresistente. Resumen en inglés Several school buildings have collapsed during past earthquakes killing many children and teachers. Venezuela has not been absent from this situation, as was demonstrated in 1997 when an Ms=6.8 earthquake lead to the collapse of four school buildings, two of them belonging to the Raimundo Martínez Centeno High School. The structural failure consisted in the collapse of the first story, leaving the slab of the first floor resting on the ground. Nonlinear dynamic analysis (mas) techniques, based on damage concentration on critical sections of the structure, were used to identify the causes of the collapse. The infill walls and the stairs significantly influence the dynamic properties of the building, reducing the vibration periods. The values defined in this work as yield story drift and ultimate story drift from a nonlinear static analysis (pushover) were found to be good estimators of the damage threshold and the collapse threshold during the dynamic response, respectively. The nonlinear dynamic response to accelerograms representing the seismic motion is characterized by a concentration of deformation at the first story that exceeds the tolerable drift values; the instability is initiated in the central frames due to the shear brittle failure of the short columns at the first story, created by the infill masonry walls inside the frames that had wide openings at the top.The failure mode resulting from the analysis is consistent with the observations at the site. A large deformation at the first story that leads to the collapse of the building is also observed when the infill walls were removed and the analysis was repeated. The collapse of both buildings was the result of the limited capacity to resist lateral loads and to dissipate energy, together with the presence of short columns that precipitated the brittle failure modes of the structure, which are typical of buildings built with old earthquake-resistance design codes.

Scientific Electronic Library Online (Spanish)

2

Drifting instabilities of cavity solitons in vertical-cavity surface-emitting lasers with frequency-selective feedback

Paulau, P. V.; Gomila, D.; Colet, Pere; Matías, Manuel A.; Loiko, N. A.; Firth, W. J.
2009-08-12

Digital.CSIC (Spain)

3

Convective instability induced by two-points nonlocality

Zambrini, Roberta; Papoff, Francesco
2006-01-23

Digital.CSIC (Spain)

4

Class A lasers with injected signal: bifurcation set and Lyapunov-potential function

Mayol, Catalina; Toral, Raúl; Mirasso, Claudio R.; Natiello, Mario A.
2002-07-17

Digital.CSIC (Spain)