Sample records for FACTOR DE DISIPACION (dissipation factor)
from WorldWideScience.org

Sample records 1 - 9 shown.



1

Riesgo sísmico en edificaciones escolares del tipo antiguo II./ Seismic risk in old type ii school buildings.

LEE, CARLOS; ABOU, FIRAS; LÓPEZ, OSCAR A
2007-06-01

Resumen en español Las escuelas del Tipo Antiguo II son edificaciones escolares construidas hace más de 50 años, con normas de diseño menos exigentes a las actuales, similares a las colapsadas en Cariaco durante el Sismo de 1997. No se disponen de planos estructurales ni arquitectónicos de estas edificaciones, así como tampoco de los cálculos utilizados en su diseño. Se presentan resultados preliminares de la evaluación sismorresistente de estas edificaciones, utilizando análisis d (mas) inámicos lineales y técnicas aproximadas de análisis estático no lineal, bajo el marco de las normas venezolanas vigentes. Se realizó una recopilación exhaustiva de las características estructurales y arquitectónicas de las escuelas en varias ciudades del país comprobándose el carácter repetitivo de estas edificaciones. Se desarrollaron planos detallados y un modelo virtual consistente en imágenes y videos digitales de la edificación. Se determinó la respuesta dinámica considerando un factor de reducción congruente con la limitada capacidad de disipación de energía de edificaciones de esa época. La capacidad del edificio a fuerza cortante fue estimada conservadoramente suponiendo un modo de colapso simultáneo de todas las columnas en cada entrepiso, incluyendo los efectos de columna corta que generan las paredes de relleno. La relación demanda elástica/capacidad, la cual suministra una estimación de la demanda global de ductilidad, es del orden de 6,3 al ignorar las paredes excediendo ampliamente el valor admisible de 2, pero se reduce a 1,4 al incluir las paredes. Se concluyóen la necesidad de adecuar estructuralmente estas escuelas, recomendándose alternativas que aprovechen las paredes como elementos sismorresistentes. Resumen en inglés The Old Type II are school buildings that were built more than 50 years ago, designed with less demanding standards than the current ones, similar to those that collapsed in Cariaco during the Earthquake of 1997. The structural and architectural drawings of these constructions are not available, neither the calculations used in their design. Preliminary results of the seismic evaluation of these constructions are presented, using elastic dynamic analysis and approximate t (mas) echniques of inelastic static analysis, under the framework of current Venezuelan standards. An exhaustive compilation of the structural and architectural characteristics of the schools was carried out in several cities of the country, confirming the repetitive character of these buildings. Detailed plans and a virtual model consisting of images and digital videos of the building were developed. The dynamic response was determined considering a reduction factor that is consistent with the limited energy dissipation capacity of constructions of that age. The capacity to shear force was estimated conservatively assuming the simultaneous collapse of all columns of one story, including the short column effects that generate the infill walls. The elastic demands/capacity ratio is approximately equal to 6.3 ignoring the walls, exceeding the acceptable value of 2, but less than this when including the walls. It is concluded that the structure of these schools should be retrofitted. Retrofitting options that take advantage of the infill walls as seismic resistant elements are recommended.

Scientific Electronic Library Online (Spanish)

2

Indicadores de riesgo sísmico en edificios escolares de Venezuela/ indicators of seismic risk in school buildings in Venezuela

López, Oscar A
2009-04-01

Resumen en español Una revisión de los efectos de 26 terremotos ocurridos en el planeta desde 19333 pone en evidencia la elevada vulnerabilidad de las edificaciones escolares que  han provocado la pérdida de miles de vidas. En el caso de Venezuela se identificaron 16 sismos ocurridos en el siglo XX que ocasionaron algún tipo de daño en escuelas. Varios edificios estructuralmente idénticos y pertenecientes a las escuelas tipo denominadas Antiguo I que fueron construidos en la década d (mas) e 1950 en diversos lugares del país, fueron dañados por los sismos de Carúpano (1.974), del Táchira (1.981), del Pilar (1.986) y de Curarigua (1.991).  En particular dos de estos edificios y otros dos pertenecientes al tipo denominado Cajetón que fueron construidos en la década de 1.970-1.980, se derrumbaron durante el sismo de Cariaco de 1.997 causando pérdidas de vidas. El mal comportamiento de estos edificios es atribuido a deficiencias sismorresistentes propias de aquellas edificaciones construidas con las normas de 1.939, 1.947, 1.955 y 1.967, a saber, poca rigidez y resistencia a carga lateral, poca capacidad de disipación de energía y la presencia de columnas cortas que precipitan modos de falla frágil. Se propone una metodología para la determinación de indicadores de riesgo y daño en una población de edificaciones escolares existentes sujeta a movimientos sísmicos. El indicador de riesgo y de daño se cuantifica en términos del cociente demanda/capacidad de desplazamiento, utilizando como información básica la edad y la localización del edificio. El procedimiento presupone que el edificio fue diseñado y construido cumpliendo con la normativa vigente en el momento de su construcción. Al no requerir de planos ni de inspecciones, esta fase puede ser aplicada a una población completa de edificios lo que permitiría posteriormente ordenarlos y seleccionar los de mayor riesgo que pasarían a la siguiente fase de evaluación que sí involucraría una inspección visual. En la metodología propuesta se requiere únicamente conocer tres parámetros de la estructura a efectos de estimar el índice de riesgo y el estado de daño producido; estos parámetros son el período efectivo, la fuerza cortante resistente expresada en forma adimensional como una fracción del peso del edificio y el factor de capacidad dúctil. Se presentan expresiones que permiten estimar la fuerza cortante resistente para un edificio escolar diseñado según las diferentes normas que han tenido vigencia en el país desde el año de 1.939. Se propone también un procedimiento para estimar la aceleración del terreno necesaria para alcanzar cada estado de daño. Un ejemplo de aplicación de la metodología propuesta en un edificio escolar típico pone de manifiesto el riesgo elevado de aquellas escuelas construidas según las normas sismorresistentes más antiguas. Resumen en inglés A revision of the effects of 26 earthquakes that took place in the planet from 1933 points out the high vulnerability of school buildings that have caused the loss of thousands of lives. In the case of Venezuela, 16 earthquakes that took place in the XX century and caused damage in schools were identified. Several buildings that belong to the denominated Old-Type I schools that were constructed in the decade of 1950 in several places of the country, were damaged by the Ca (mas) rúpano (1974), Táchira (1981), El Pilar (1.986) and Curarigua (1991) earthquakes. In particular, two of these buildings and other two that belongs to the denominated Box-Type schools that were constructed in the decade of 1970-1980, collapsed during the Cariaco 1997 earthquake causing loss of lives. The poor behavior of these structures is attributed to earthquake-resistant deficiencies that were typical of buildings constructed with the codes of 1939, 1947, 1955 and 1967, that is to say, low stiffness and resistance to lateral load, low energy dissipation capacity and the presence of short columns that precipitate brittle failure modes. A methodology for the determination of risk and damage indicators in a population of existing school buildings subjected to seismic motion is proposed. The damage and risk indicators are quantified in terms of the ratio between the displacement demand and the displacement capacity, using the age and the location of the building as basic information. The procedure assumes that the building was designed and constructed fulfilling the building code at the moment of its construction. Since this methodology do not require structural planes nor of inspection at the site, it can be applied to a complete population of buildings which would later allow selecting those of greater risk index that would go to the following phase of evaluation involving a visual inspection. In the proposed methodology it is only required to know three parameters in order to determine the risk index and the state of damage; these parameters are the effective period, the resisting base shear force expressed in non-dimensional form as a fraction of the weight of the building, and the factor of ductile capacity. Expressions to estimate the resisting base shear force for school  buildings designed according to the different codes that have been in use in the country from the year of 1939, is presented. A procedure to estimate the peak ground acceleration necessary to reach each damage state is proposed. An example of application of the propose methodology in a typical school building shows the elevated risk of those schools constructed according to the older seismic codes.

Scientific Electronic Library Online (Spanish)

3

El Niño-Oscilación del Sur (ENOS) y los frentes fríos que arriban a la región occidental cubana/ ENSO and cold fronts arrival in Cuban western region

Hernández, Benigno
2002-01-01

Resumen en español RESUMEN. Se analiza el periodo invernal del arribo de frentes desde 1923-24 a 1995-96 existiendo una relación positiva directa en los incrementos del arribo de frentes fríos que penetran por la región occidental de Cuba con años donde ocurren eventos ENOS. Las variables meteorológicas más importantes que acompañan a los frentes como la temperatura del aire, presión atmosférica y lluvia, varían con respecto a su media histórica. La temperatura superficial del ma (mas) r en el golfo de México, es un factor que parece influenciar en un mayor o menor grado el arribo de frentes y la disipación de algunos de ellos cuando atraviesan el mismo. El Análisis de Épocas Superpuestas muestra asociación significativa entre el efecto de los eventos ENOS sobre el aumento en el arribo de frentes fríos a la región occidental de Cuba y algunas variables meteorológicas, por lo que se considera una herramienta estadística apropiada y útil Resumen en inglés Cold front arrivals in winter season is analyzed from 1923-24 to 1995-96 existing a direct positive relationship in the increases of cold fronts in ENSO years in the western region of Cuba. Most important variables in the front's arrivals as air temperature, sea level pressure and rainfall suffer variations with respect to historical average is analyzed. Gulf of Mexico SST is probably factor that seems to influence in a great or smaller fronts arrivals or dissipation of s (mas) ome of then when cross through the Gulf of Mexico. Superposed Epoch Analysis (SEA) offered a significant association degree among ENSO events in the increase of cold fronts arrivals in Cuban western region, for that is considered an appropriate and useful statistical tool

Scientific Electronic Library Online (Spanish)

4

La circulación cerebral en condiciones normales y patológicas VI: el caso del vasoespasmo

Fontana, Horacio; Belziti, Héctor; Buratt, Sebastián
2009-12-01

Resumen en español En la base del cerebro tenemos un sistema arterial de alta velocidad y de gran disipación de energía de la masa circulante por rozamiento (flujo alterado), con vasos colaterales que se benefician de estos fenómenos, con una baja presión, que podría tener importancia en la patología isquémica a este nivel; y una zona distal, a la que la corriente sanguínea llega con menor velocidad y presión, comparativamente con los vasos extracraneanos del mismo calibre. Es posi (mas) ble que el aumento de velocidad en las arterias de la base después de HSA se deba a una disminución de la resistencia periférica, por Suna abolición de la autorregulación. El aumento de velocidad disminuye la presión lateral en las arterias por el principio de la conservación de la energía, lo que a su vez produce disminución pasiva del diámetro de la arteria. Esto hace que el espesor de la pared aumente, aumentando el tono vascular, que disminuye el calibre del vaso, por lo que aumenta la velocidad, generándose un círculo vicioso. Otro factor que puede influir es la presión extravascular (PIC) y los coágulos en el espacio subaracnoideo.Con la autorregulación abolida la isquemia es inminente, favorecida por el aumento de resistencia debido a la disminución del calibre vascular. La hipertensión endocraneana se explica por la hiperemia en los territorios vasodilatados, espontánea o provocada en forma iatrogénica.El trastorno de la microcirculación puede ser estudiado por el tiempo de circulación cerebral, el test de hiperemia transitoria, la prueba de la acetazolamida y la reactividad al aumento de pCO2. La autorregulación abolida precede a la manifestación del vasoespasmo en varios días. Este proceso fisiopatológico mecánico es presentado en forma hipotética, con sus implicancias para el tratamiento. Resumen en inglés The basal brain arteries are a system of high flow velocity and high shear stress and energy dissipation, with collateral vessels that get profit from those facts, with a low pressure, that could have some influence in the ischemic pathology at this level, and a distal zone where the flow arrives with lower energy, comparatively with extracranial vessels of the same calibre. It is possible that the increase of flow velocity at the basal arteries after SAH be a consequence (mas) of a diminished peripheral resistance due to autoregulation abolition. Because of the principle of energy preservation, the increase in velocity diminishes the lateral pressure producing a passive diameter decrease of the artery, increasing the width of the wall, that increases the vascular tone, and tends to decrease the diameter, closing a noid hemorrhage using a transient hyperemic response test of vicious circle. Other factors are the extraluminal pressure and the presence of clots outside the vessel wall. With abolished autorregulation, ischemia is impending, facilitated by the increased resistance opposed by the diminished diameter of the vessels. The intracranial hypertension can be explained by the spotaneous or iatrogenic hyperemia. The microcirculatory trouble proposed can be assessed by the cerebral circulatory time, the transient hyperemia test, the test of acetazolamide and the reactivity to the increase in pCO2. The abolition of autorregulation so displayed, precedes vasospasm for days. This mechanical physiopathological process is presented hypothetically, with its eventual therapeutic consequences.

Scientific Electronic Library Online (Spanish)

5

The ATLAS semiconductor tracker end-cap module

Fleta, Celeste; Martí García, Salvador; Lacasta Llácer, Carlos; Fuster, Juan; Rafí, Joan Marc; García García, Carmen; Stugu, Bjarne; Mellado, B.; Bernabéu, José; García-Navarro, José Enrique; Ullán Comes, Miguel; González González, Francisco; González Sevilla, Sergio; Modesto, Pablo; Campabadal, Francesca; Llosá, Gabriela; Lozano Fantoba, Manuel; Costa, María José; Escobar, Carlos; Pellegrini, Giulio; Rodríguez Oliete, Rosario; Sánchez Martínez, Francisco Javier; Strachko, V.; Civera, José Vicente; Miñano, Mercedes; Oye, O. K.; Sospedra, Luis
2007-02-28

Digital.CSIC (Spain)

6

Photothermal characterization and stability analysis of polymeric dye lasers

Duchowicz, Ricardo; Scaffardi, Lucía B.; Costela González, Ángel; García Moreno, Inmaculada; Sastre Muñoz, Roberto; Acuña Fernandez, Alberto Ulises
2000-01-01

Digital.CSIC (Spain)

7

Photosynthesis and photoprotection responses to water stress in the wild-extinct plant Lysimachia minoricensis

Galmés, Jeroni; Abadía Bayona, Anunciación; Medrano Gil, Hipólito; Flexas, Jaume
2007-01-07

Digital.CSIC (Spain)

8

High-Q dynamic force microscopy in liquid and its application to living cells

Tamayo, Javier; Humphris, A. D. L.; Owen, R. J.; Miles, M. J.
2001-07-01

Digital.CSIC (Spain)