Sample records for COBALTO 70 (cobalt 70)
from WorldWideScience.org

Sample records 1 - 8 shown.



1

Efectos del Cloruro de Cobalto sobre el Epitelio de Unión y Epitelio Reducido del Esmalte del Primer Molar Superior de Rata/ Effects of Cobalt Chloride in Junctional Epithelium and Reduced Enamel Epithelium of the Rat Maxillary First Molar

Felippini, Ana Luiza de C; Lopes, Ruberval Armando; Sala, Miguel Angel; Watanabe, Ii-Sei; Lopes, Túlio Roberto V.P; Issa, João Paulo M; Ribas, José Paulo
2009-12-01

Resumen en español El cobalto es uno de los principales componentes de las aleaciones metálicas fundidas, usadas frecuentemente en odontología. El metal es el constituyente de 45 a 70% de los trabajos protéticos. En virtud de la existencia de evidencias que elementos metálicos pueden causar toxicidad sistémica y local, este trabajo tuvo como objetivo evaluar los efectos del cobalto sobre el epitelio de unión y el epitelio del esmalte del primer molar superior de rata, durante la lacta (mas) ncia. Con esa finalidad fueron usadas ratas con 1 día de vida postnatal, cuyas madres recibieron 300 mg de cloruro de cobalto por litro de agua destilada en el bebedero, durante a la lactancia. Al cabo de 21 días, las crías fueron sacrificadas con sobredosis anestésica. Las cabezas fueron separadas, fijadas en "alfac", descalcificadas e incluidas en parafina. Fueron utilizados cortes frontales seriados teñidos con hematoxilina y eosina. Fueron estimados los siguientes parámetros nucleares: diámetros mayor, menor y geométrico medio, relación entre diámetros, perímetro, área, volumen, relación entre volumen y área, excentricidad, coeficiente de forma e índice de contorno. Mediante métodos estereológicos fueron evaluados: relación núcleo/citoplasma, volumen celular, densidad numérica celular, relación superficie externa/camada basal, espesor de las camadas epiteliales y densidad de superficie. Todos los datos obtenidos fueron sometidos a análisis estadístico mediante la prueba no-paramétrica de Wilcoxon-Mann-Whitney. Los núcleos de los tejidos estudiados mostraron valores menores para diámetros, perímetro, área, volumen y relación volumen/área. Estereológicamente, fue posible observar en el epitelio de unión y en el epitelio reducido del esmalte, células menores con citoplasma más escaso, lo que se refleja en mayor número de células por mm³ de tejido. En este estudio, el cobalto ocasionó un cuadro de atrofia epitelial, sugiriendo una acción directa sobre los epitelios de unión y del esmalte Resumen en inglés Cobalt is one of the main components of cast metal alloys broadly used in dentistry. It is the constituent of 45 to 70% of numerous prosthetic works. There are evidences that metal elements cause systemic and local toxicity. The purpose of the present study was to evaluate the effects of cobalt on the junctional epithelium and reduced enamel epithelium of the first superior molar in rats, during lactation. To do this, 1-day old rats were used, whose mothers received 300mg (mas) of cobalt chloride per liter of distilled water in the drinker, during lactation. After 21 days, the rat pups were killed with an anesthetic overdose. The heads were separated, fixed in "alfac", decalcified and embedded in paraffin. Frontal sections stained with hematoxylin and eosin were employed. Karyometric methods allowed to estimate the following parameters: biggest, smallest and mean diameters, D/d ratio, perimeter, area, volume, volume/area ratio, eccentricity, form coefficient and contour index. Stereologic methods allow to evaluate: cytoplasm/nucleus ratio, cell and cytoplasm volume, cell number density, external surface/basal membrane ratio, thickness of the epithelial layers and surface density. All the collected data were subjected to statistic analysis by the non-parametric Wilcoxon-Mann-Whitney test. The nuclei of the studied tissues showed smaller values after karyometry for: diameters; perimeter, area, volume and volume/area ratio. Stereologically, it was observed, in the junctional epithelium and in the reduced enamel epithelium, smaller cells with scarce cytoplasm, reflected in the greater number of cells per mm3 of tissue. In this study, cobalt caused epithelial atrophy, indicating a direct action on the junctional and enamel epithelium

Scientific Electronic Library Online (Spanish)

2

Desarrollo de un recubrimiento electrolítico estaño-cobalto alternativo mediante la aplicación de técnicas de manipulación de corriente

Rodríguez, Boet; Hernández Santaella, Luisa Teresa; José, Omar
2007-07-01

Resumen en español En el presente trabajo se presenta el desarrollo de un recubrimiento electrolítico Estaño-Cobalto con excelentes propiedades decorativas, aplicando las técnicas de manipulación de corriente, sin baños de elevada toxicidad ambiental. Se determinó que a un pH 8, temperatura de 60ºC, densidad de corriente promedio de 2 A/dm2, densidad de corriente catódica de 14 A/dm2 y un tiempo de encendido de 4 ms y de apagado de 24 ms con un ciclo duty de 14.28% se obtiene la mej (mas) or calidad estética del recubrimiento, la cual está caracterizada por un brillo de 22.8 y una rugosidad media Ra 0.27 μm y Rz 1.9 μm, teniendo un poder nivelante de 70.5% en comparación al sustrato. De igual forma, el electrodepósito presenta una resistencia eléctrica de poro sobre cobre de 2.363 K_.Cm2 y un potencial de corrosión de -323.2 mV. Con la corriente pulso se observó por microscopia electrónica que favorece la nucleación entre pulsos,produciendo depósitos con propiedades superiores a las obtenidas con corriente continua, sin necesidad de aditivos abrillantadores y contaminantes. Mediante el análisis de energía electrodispersiva se pudo establecer para la composición química de los electrodepósitos obtenidos, una relación molar aproximada de Sn-Co en 1:1. Resumen en inglés DEVELOPMENT OF AN ELECTROLYTIC COATING TIN-COBALT ALLOY PLATING ALTERNATIVE BY TECHNIQUES OF CURRENT MODULATION Abstract: To study and evaluate the plating conditions and processes for preparation of tin-cobalt alloys, an alternative coating current modulation technique was used. As a result, it was found that the surface plating is optimal when it was plated under a duty cycle of 14.28%. A peak pulsed current density of 14 A/dm2 is required for an average current density (mas) of 2 A/dm2 with a solution temperature of 50oC at pH 8. The effect of pulsed current plating upon the structure of the deposits from a pyrophosphate baths, without additives, has confirmed an increase in brightness, reduction in grain size and a progressive transition of structure from columnar to lamellar. The use of pulse current plating parameters that result in grain refinement will also lead to a reduction in porosity of the deposits, as compared with constant current plating. Scanning electronic micrographs show that it is possible obtain more uniform tin-cobalt alloys deposits by pulsed plating. The analysis by EDX showed that the composition of the tin-cobalt alloy and the molar ratio was 1: 1.

Scientific Electronic Library Online (Spanish)

3

Metales pesados en suelo urbano como un indicador de la calidad ambiental: ciudad de Chihuahua, México/ Heavy metals in urban land as an indicator of environmental quality: city of Chihuahua, México

Alcalá, Jorge; Sosa, Manuel; Moreno, Myriam; Rodríguez, Juan C.; Quintana, César; Terrazas, César; Rivero, Oved
2009-12-01

Resumen en español El crecimiento de las ciudades ejerce presión sobre el conocimiento de la calidad del suelo y su asociación como factor de contaminación, debido a que su condición trae efectos a la salud humana, principalmente por la concentración de metales pesados. Con el objetivo de determinar las concentraciones de Níquel (Ni), Cobalto (Co), Vanadio (V) y Plomo (Pb) en la ciudad de Chihuahua fueron tomadas muestras de suelo en sitios donde se desarrollan 75 árboles de cinco es (mas) pecies. Los muestreos se realizaron conforme a los usos de suelo Comercial y Servicios, Industria Mixta, Industria Pesada, Residencial modalidades Media-Alta y Residencial Popular durante las temporadas de otoño, primavera y verano. Para determinar las concentraciones de metales fue empleada la Técnica ICP descrita como espectrometría óptica con plasma acoplado inductivamente. Con un modelo ajustado mediante el Minitab® se probaron los efectos de las interacciones de la especie, tipo de uso de suelo y temporada con respecto a las concentraciones de metales pesados en suelos. Las interacciones significativas encontradas fueron entre temporada-tipo de uso de suelo con Ni, Co, V y Pb, además de la temporada-especie con respecto al Vanadio. Se destaca que en el sitio referente al área de la Industria Pesada, el Pb obtuvo una concentración de 1714,70±1,30 mg/kg, rebasando la NOM-147- SEMARNAT/SSA1-2004 que marca como límite 800 mg/kg para este uso de suelo. Se considera necesario este tipo de información para la planeación urbana de la ciudad, así como su impacto en cuanto a salud pública y la mitigación de la contaminación ambiental. Resumen en inglés Growth of cities is putting pressure on soil quality research and its association as a factor of pollution, because its condition leads up effects to human health, mainly by the concentration of heavy metals. In order to determine the concentrations of Nickel (Ni), Cobalt (Co), Vanadium (V) and Lead (Pb) in the city of Chihuahua, soil samples were taken at sites where 75 trees of five species are growing. Samplings were conducted in accordance with the land uses and Comme (mas) rcial and Services, Mixed Industry, Heavy Industry, Middle upper class Residential areas and Low class Residential areas during autumn, spring and summer seasons. In order to determine the concentrations of metals, the technique described as ICP (spectrometer optics inductively coupled plasma) was employed. With a model adjusted through Minitab® the effects of the species, type of land use and season interactions were tested with respect to heavy metal concentration in soils. The significant interactions found were between season-type of land use with Ni, Co, V and Pb in addition to the season-species with respect to Vanadium. It is emphasized that the site in relation to the Heavy Industry area Pb concentration was of 1714,70 mg/kg surpassing the NOM-147-SEMARNAT/SSA1- 2004 which establishes a limit of 800 mg/kg for this land use. This type of information is considered necessary for urban planning of the city, and for its impact in public health and the mitigation of environmental pollution.

Scientific Electronic Library Online (Spanish)

4

Magnetostatic coupling in soft/hard biphase magnetic systems based on amorphous alloys

Torrejón, J.; Kraus, L.; Pirota, K. R.; Badini-Confalonieri, Giovanni Andrea; Vázquez Villalabeitia, Manuel
2007-04-18

Digital.CSIC (Spain)

5

Magnetic properties of ultrathin FexCo(1-x) films on Pt(111)

Moulas, G.; Lehnert, A.; Rusponi, S.; Zabloudil, J.; Etz, C.; Ouazi, S.; Etzkorn, M.; Bencok, Peter; Gambardella, Pietro; Weinberger, P.; Brune, H.
2008-12-17

Digital.CSIC (Spain)

6

Influence of the interfaces on the anisotropic magnetoresistance of Ni/Co multilayers

Lesmes, Felipe; Salcedo, A.; Freijo, J. J.; García, D.; Hernando, Antonio; Prados, C.
1996-10-21

Digital.CSIC (Spain)

7

Finite-sized Heisenberg chains and magnetism of one-dimensional metal systems

Vindigni, A.; Rettori, A.; Pini, M. G.; Carbone, C.; Gambardella, Pietro
2006-02-01

Digital.CSIC (Spain)

8

Experimental evidence of pressure-induced suppression of the cobalt magnetic moment in ErCo2

Ishimatsu, N.; Miyamoto, S.; Maruyama, H.; Chaboy, J.; Laguna-Marco, M. A.; Kawamura, N.
2007-05-01

Digital.CSIC (Spain)