WorldWideScience

Sample records for mwpc wire tension

  1. Development of a portable and fast wire tension measurement system for MWPC construction

    Science.gov (United States)

    Pan, Jing-Hui; Ma, Chang-Li; Gong, Xue-Yu; Sun, Zhi-Jia; Wang, Yan-Feng; Yin, Chen-Yan; Gong, Lei

    2016-09-01

    In a multi-wire proportional chamber detector (MWPC), the anode and signal wires must maintain suitable tension, which is very important for the detector’s stable and accurate performance. As a result, wire tension control and measurement is essential in MWPC construction. A high pressure 3He MWPC detector is to be used as the thermal neutron detector of the multi-functional reflectometer at China Spallation Neutron Source, and in the construction of the detector, we have developed a wire tension measurement system. This system is accurate, portable and time-saving. With it, the wire tension on an anode wire plane has been tested. The measurement results show that the wire tension control techniques used in detector manufacture are reliable. Supported by National Natural Science Foundation of China (A050506), State Key Laboratory of Particle Detection and Electronics and Key Laboratory of China Academy of Engineering Physics (Y490KF40HD)

  2. Development of a portable, fast and contactless wire tension measurement system for MWPC's construction

    CERN Document Server

    Pan, Jing-Hui; Gong, Xue-Yu; Sun, Zhi-Jia; Wang, Yan-Feng; Yin, Chen-Yan; Gong, Lei

    2016-01-01

    In a multi-wire proportional chamber detector(MWPC), the anode and signal wires must maintain suitable tensions, which is very important for making the detector have steady and perfect performance. As a result, wire tension control and measurement is essential in MWPC's construction. The thermal neutron detector of multi-functional reflectometer at China Spallation Neutron Source is designed using a hight pressure $^{3}$He MWPC detector, and in the construction of the detector, we developed a wire tension measurement system. This system is accurate, portable and time-saving. And, the wires' tension on a anode wire plane has been tested with it, the measurement results shown the wire tension control techniques used in detector manufacture is reliable.

  3. P-KTPx: Production and Certification of MWPC for LHCb Muon System at CERN

    CERN Multimedia

    2005-01-01

    - The Large Hadron Collider beauty experiment - Multi Wire Proportional Chambers (MWPC) in the LHCb Muon System - Design Parameters MWPC Production at CERN - Panel Production - Panel Wiring Chamber Certification - Gas Leak Test - Chamber Conditioning - Gas Gain Uniformity Test

  4. Wire ropes tension, endurance, reliability

    CERN Document Server

    Feyrer, Klaus

    2015-01-01

    The main goal of this book is to present the methods used to calculate the most important parameters for ropes, and to explain how they are applied on the basis of numerous sample calculations. The book, based on the most important chapters of the German book DRAHTSEILE, has been updated to reflect the latest developments, with the new edition especially focusing on computational methods for wire ropes. Many new calculations and examples have also been added to facilitate the dimensioning and calculation of mechanical characteristics of wire ropes. This book offers a valuable resource for all those working with wire ropes, including construction engineers, operators and supervisors of machines and installations involving wire ropes.

  5. A high-pressure MWPC detector for crystallography

    DEFF Research Database (Denmark)

    Ortuno-Prados, F.; Bazzano, A.; Berry, A.;

    1999-01-01

    The application of the Multi-Wire Proportional Counter (MWPC) as a potential detector for protein crystallography and other wide-angle diffraction experiments is presented. Electrostatic problems found with our large area MWPC when operated at high pressure are discussed. We suggest that a solution...

  6. Effect of Tension on Friction Coefficient Between Lining and Wire Rope with Low Speed Sliding

    Institute of Scientific and Technical Information of China (English)

    PENG Yu-xing; ZHU Zhen-cai; CHEN Guo-an; CAO Guo-hua

    2007-01-01

    In order to obtain the exact friction coefficient between lining and wire rope, the tension of wire rope is studied as a factor which affects this coefficient. A mechanical model of a wire rope subjected to axial load was established to determine the torque of the wire rope. The contact motion between lining and wire rope was regarded as a screw rotation and the axial force of the lining resulting from the torque of the wire rope was analyzed. Theoretical formulas relating tension of the wire rope and the friction coefficient was obtained. Experiments between lining and wire rope with low sliding speed were carried out with friction tester made by us. Experimental results show that increment of the friction coefficient is proportional to that of the tension of the wire rope with a low sliding speed. The experimental results agree with the theoretical calculation; the errors are less than 6%, which proves the validity of the theoretical model.

  7. K-wire position in tension-band wiring technique affects stability of wires and long-term outcome in surgical treatment of olecranon fractures.

    NARCIS (Netherlands)

    Linden, S.C. van der; Kampen, A. van; Jaarsma, R.L.

    2012-01-01

    BACKGROUND: Tension-band wiring (TBW) has been accepted as the treatment of choice for displaced olecranon fractures. The aim of this study was to examine the effect of K-wire position on instability of the K-wires in relation to local complications and radiological and clinical long-term outcome. M

  8. Delayed migration of K-wire into popliteal fossa used for tension band wiring of patellar fracture

    Institute of Scientific and Technical Information of China (English)

    Sanjay Meena; Hira Lal Nag; Senthil Kumar; Nilesh Barwar; Samarth Mittal; Amit Singla

    2013-01-01

    Breakage of K-wires and stainless steel wires which are used for fracture fixation is not uncommon,but migration is rare.We report a case of migration of broken K-wire used for patella tension band wiring to the popliteal fossa.The broken hardware was removed surgically.We would like to suggest that K-wire and wire fixation used for treatment ofpatellar fractures can migrate into the posterior compartment of the knee and cause clinical symptoms.Close clinical and radiological follow-up after internal fixation to identify the presence of hardware breakage or movement and removal of wires once fracture has united can avert such complications.

  9. Complications and re-operation rate after tension-band wiring of olecranon fractures

    DEFF Research Database (Denmark)

    Romero, J M; Miran, A; Jensen, Claus Hjorth

    2000-01-01

    Tension-band wire fixation of olecranon fractures leads to a high re-operation rate because of the need to remove the metalware. This problem has commonly been thought to be related mainly to the backing-out of the Kirschner wires. A retrospective study was carried out in 55 patients with displaced...... olecranon fractures operated on with the tension-band wiring technique, in whom there was an overall 71.7% re-operation rate. Complications were few and minor in most patients. The main reason for the removal of the metalware was a direct complaint from the patient (in 61.3% of all removals). A literature...

  10. A STUDY ON THE MANAGEMENT OF DISPLACED FRACTURES OF PATELLA USING MODIFIED TENSION BAND WIRING

    Directory of Open Access Journals (Sweden)

    Hari Babu

    2015-10-01

    Full Text Available INTRODUCTION: Patella is an important component of the extensor mechanism of the knee. A patella fracture constitutes 1% of all skeletal fractures resulting from either direct or indirect trauma. Any improper and inadequate treatment would inevitably lead to a disability which would be most perceptibly felt in a country like India, where squatting is important activity in daily life. The goal of treatment is to regain the continuity of the extensor mechanism and congruity of patellofemoral a rticulation so that the normal function of the knee can be restored. Several techniques have been described for internal fixation of fractures of patella. The ideal fixation for the fracture patella is that it should be strong enough to allow early mobiliz ation, reduce posttraumatic stiffness and perhaps help the healing of the articular surface . AIMS: To analyze the functional outcome of displaced transverse fractures of the patella treated by Modified Tension Band Wiring principle (Muller using A. Dutta & S. K. Gupta Scoring System. To extend the application of Modified Tension Band wiring for minimally comminuted fractures of patella and assesses the results. CONCLUSION : The present study shows that modified tension band wiring (Muller is an effective p rocedure in the management of displaced transverse patellar fractures, with excellent to good results. Minimally comminuted patellar fractures also yielded excellent to good results with Modified tension band wiring as an extended application. The results in the present study are comparable to other modifications of Tension Band Wiring principle. The surgery of Modified Tension Band Wiring gives rigid fixation and helps in early mobilization. Regular and scheduled post- operative physiotherapy plays an impor tant role in the functional outcome.

  11. Dual Position Sensitive MWPC for tracking reaction products at VAMOS++

    CERN Document Server

    Vandebrouck, Marine; Rejmund, Maurycy; Fremont, Georges; Pancin, Julien; Navin, Alahari; Michelagnoli, Caterina; Goupil, Johan; Spitaels, Charles; Jacquot, Bertrand

    2015-01-01

    The characteristics and performance of a Dual Position Sensitive Multi-Wire Proportional Counter (DPS-MWPC) used to measure the scattering angle, interaction position on the target and the velocity of reaction products, detected in the VAMOS++ magnetic spectrometer, are reported. The detector consists of a pair of position sensitive low pressure MWPCs and provides both fast timing signals, along with the two-dimensional position coordinates required to define the trajectory of the reaction products. A time-of-flight resolution of 305(11) ps (FWHM) was measured. The measured resolutions (FWHM) were 2.5(3) mrad and 560(70) {\\mu}m for the scattering angle and the interaction point at the target respectively. The subsequent improvement of the Doppler correction of the energy of the gamma-rays, detected in the gamma-ray tracking array AGATA in coincidence with isotopically identified ions in VAMOS++, is also discussed.

  12. [Separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella].

    Science.gov (United States)

    Zhang, J; Jiang, X Y; Huang, X W

    2016-06-18

    To investigate the clinical efficacy and outcomes of two separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella. From January 2013 to January 2015, 15 consecutive patients (mean age 54.5 years) with inferior pole fractures of the patella were retrospectively included in this study. All the patients underwent open reduction and internal fixation by separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire through longitudinal incision, 4.5 d (range: 3.1-5.9 d) after initial injury. A safety check for early knee range of motion was performed before wound closure. The complications including infection, nonunion, loss of fixation and any wire breakage or irritation from implant were recorded. Anteroposterior and lateral views of the knee joint obtained during the follow-up were used to assess bony union based on the time when the fracture line disappeared. At the time of the final outpatient follow up, functional evaluation of the knee joint was conducted by Bostman system. The follow-up time was 13.1 months (range: 12-19 months) after surgery on average, immediate motion without immobilization in all the cases was allowed and there was no case of reduction loss of the fracture and wire breakage. There was no case of irritation from the implant. At the final follow-up, the average range of motion (ROM) arc was 126.7° (range: 115°-140°), the average ROM lag versus contralateral healthy leg was 10.3° (range: 0°-35°). The mean Bostman score at the last follow-up was 28.9 (range: 27-30), and graded excellent in most cases. Two separate vertical wiring is an easy and effective method to reduce the displaced inferior pole fracture of patella. Augmentation of separate vertical wiring with tension band and Kirschner-wire plus cerclage wire in these patients provides enough strength to protected the early exercise of the knee joint and

  13. Horizontal versus vertical orientation of the loop for tension band wiring of transverse patella fractures.

    Science.gov (United States)

    Lee, Sang Ki; Hwang, Yoon Sub; Choy, Won Sik

    2014-03-01

    Conventional operative treatments of patella fractures are frequently associated with implant failure or displacement. Recent biomechanical studies showed that the orientation of the wire loop and the site of the wire twist can affect the fixation strength. The purpose of this study was to compare the clinical outcome of the tension band technique with loops in different orientations and different knot positions. For this retrospective study, 72 patella fractures (71 patients) were fixed with figure-of-eight configurations in combination with 2 K-wires. Patients were divided into 3 groups according to the orientation of tension band construct. A total of 40 patella fractures were placed with figure-of-eight configurations in a vertical orientation either with 1 wire twist (group 1; 16 patella fractures) or with 2 wire twists at the adjacent corners (group 2; 24 patella fractures). Thirty-two patella fractures were placed with figure-of-eight configurations in a horizontal orientation with 2 wire twists at the adjacent corners (group 3). Range of motion, complication rates, and knee scoring scales (Hospital for Special Surgery and Lysholm) were assessed during serial follow-up. Satisfactory reductions were achieved in all groups, but functional results in the early stage were different. Group 3 had better Hospital for Special Surgery and Lysholm scores at 3 months postoperatively; however, at 6 months and 1 year postoperatively, all groups had similar scores. At the 1-year follow-up, all groups achieved acceptable flexion and range of motion. The overall complication rate was lower in the horizontal group (12.5%). Placing the figure-of-eight tension band construct in a horizontal orientation can provide functional benefits in the early stage after patella fractures. Copyright 2014, SLACK Incorporated.

  14. Design of strain tension sensor of steel wire rope used in the coal mine

    Science.gov (United States)

    Zhang, Xin; Jin, Huawei

    2016-01-01

    According to the dynamic tension testing requirements of the multi-rope winder rope, this paper designs the sensor used to measure the tension of steel wire rope directly. The sensor uses the strain shear measuring principle, and has many features with small size, big measuring range, easy to install, don't change the structure of connected devices and so on. Application of the finite element analysis software makes the structure of the sensor optimized, and then enhance the static and dynamic performance of the sensor.

  15. The determination of optimal initial tension in rat coronary artery using wire myography.

    Science.gov (United States)

    Ping, N-N; Cao, L; Xiao, X; Li, S; Cao, Y-X

    2014-01-01

    The aim of the present study was to determine the optimal initial tension, i.e. initial stretch for rat coronary artery when using the multi-wire myograph system. We used the normalization procedure to mimic physiological conditions and to stretch the coronary arterial segments to normalized internal circumference (IC(1)). It is determined the internal circumference when the vessel relaxed under a transmural pressure of 100 mm Hg (IC(100)), and the IC(1) is calculated by multiplying the IC(100) by a factor k. The impact of different factor k on the initial stretch and agonist-induced tension of coronary arteries were investigated. The results showed that the maximal agonist-induced tension was achieved at the factor k value of 0.90 and the initial stretch tension was given 1.16+/-0.04 mN/mm. The most appropriate factor k value was 0.90-0.95 and the most appropriate initial tension was 1.16-1.52 mN/mm. The equilibration time of the coronary artery segments should be at least 1.0 h. In the same optimal initial tension, the agonist-induced tension increased as equilibration time lengthened.

  16. Internal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring

    Directory of Open Access Journals (Sweden)

    Khan I

    2016-07-01

    Full Text Available Aims: To evaluate the effectiveness and safety of anterior tension band wiring technique using two cannulated cancellous screws in patients with transverse (AO34-C1 or transverse with mildly comminuted (AO34-C2 patellar fractures. Materials and Methods: This is a prospective study of 25 patients with transverse fracture or transverse fracture with mildly comminuted patella fractures. All the patients were treated with open reduction and internal fixation using two parallel cannulated screws and 18G stainless steel wire as per the tension band principle. Results: There were eighteen males (72% and seven females (28%. The age group ranged from 24 to 58 years, with mean age of 38 years. The most common mode of injury was fall (72% followed by road traffic accident (20% and violent quadriceps contraction (8%. Transverse fracture was present in 60% and transverse fracture with mild comminution in 40% of patients. Mean time to achieve union was 10.7 weeks (range 8-12 weeks. Mean ROM at three months was 113.8 degree (90-130 and at final follow up this improved to 125.4 degrees (range 100-140. There was one case of knee stiffness and no case of implant failure was observed. Patients were evaluated using Bostman scoring, the mean score at three months being 26.04 which improved to 27.36 at the end of final follow up at one year. Conclusion: Cannulated cancellous screws with anterior tension band wiring is a safe, reliable and reproducible method in management of transverse patellar fractures, with less chances of implant failure and soft tissue irritation.

  17. Migration of a Kirschner wire to the dorsolateral side of the foot following osteosynthesis of a patella fracture with tension band wiring: a case report

    OpenAIRE

    Aydın, Ekrem; Dülgeroğlu, Turan Cihan; Metineren, Hasan

    2016-01-01

    Background Patella fractures represent 1 % of all musculoskeletal system fractures. Fixation of patellar fractures using open reduction and tension band wiring is a commonly used and successful surgical fixation method. Case presentation A 28-year-old male patient from Turkey presented to our clinic with complaints of palpable foreign bodies under the skin on the dorsolateral side of his right foot. Except for the palpable and moving body of about 6 cm length under the skin in his foot, he ha...

  18. Biomedical applications of digital autoradiography with a MWPC

    Energy Technology Data Exchange (ETDEWEB)

    Bellazzini, R.; Betti, G.; Del Guerra, A.; Massai, M.M.; Ragadini, M.; Spandre, G.; Tonelli, G.; Venturi, R.; Zito, F.

    1982-05-01

    A Multiwire Proportional Chamber (MWPC) was used as a ..beta../sup -/ radioactivity detector in biological and medical applications. Two different kinds of experiments were performed: the study of variations in the ability of cell clones to incorporate a radioactive precursor of DNA biosynthesis (/sup 3/H-thymidine) and the regional carbohydrate consumption in myocardial tissue by means of a deposit tracer of glucose metabolism (/sup 3/H-deoxyglucose).

  19. Biomedical applications of digital autoradiography with a MWPC

    Energy Technology Data Exchange (ETDEWEB)

    Bellazzini, R.; Betti, G.; Del Guerra, A.; Massai, M.M.; Ragadini, M.; Spandre, G.; Tonelli, G.; Venturi, R.; Zito, F.

    1982-05-01

    A Multiwire Proportional Chamber (MWPC) was used as a ..beta../sup -/ radioactivity detector in biological and medical applications. Two different kinds of experiments were performed: the study of variations in the ability of cell clones to incorporate a radioactive precursor of DNA biosynthesis (/sup 3/H-thymidine) and the regional carbohydrate consumption in myocardial tissue by means of a deposit tracer of glucose metabolism (/sup 3/H-deoxyglucose).

  20. 多线切割机线张力自适应控制仿真研究%Simulating Adaptive Control over Wire Tension of Multi-wire Saw

    Institute of Scientific and Technical Information of China (English)

    黄洁; 李伟

    2012-01-01

    We establish the mathematical model of a multi-wire tension control system and design an adaptive control algorithm for the control of the wire tension.The adaptive control algorithm uses the NLMS(normalized least mean squares) algorithm to perform the adaptive and dynamic correction of the rotational speed of the multi-wire saw with the rotational speed and angle fed back by the tension control motor so as to control the wire tension more accurately.The Matlab simulation results show that our adaptive control algorithm can accurately control the wire tension of the multi-wire saw.%针对力矩电机张力控制方式的特点,分析和建立了多线切割机张力控制系统的数学模型,并在此基础上,设计了线张力自适应控制算法。该算法通过张力控制电机反馈的转速和转角大小,利用NLMS算法对收/放线电机的转速进行自适应动态修正,提高对主轴电机的线速度跟随精度,最终达到精确控制张力的目的。Matlab仿真结果表明:该控制算法对张力的控制精度高、响应速度快,可以满足多线切割加工对张力控制的要求。

  1. Atraumatic Restoration of Vertical Food Impaction with an Open Contact Using Flowable Composite Resin Aided by Cerclage Wire under Tension.

    Science.gov (United States)

    Li, Quan-Li; Ying Cao, Chris; Xu, Qiang-Jian; Xu, Xiao-Hua; Yin, Jia-Li

    2016-01-01

    To date, treating vertical food impaction with open contact effectively, especially with an atraumatic therapy, remains a challenge. In this study, we developed a simple, atraumatic, and economic therapeutic measure to treat vertical food impaction. The scientific rationale of our therapeutic technique is to restore an intact and firm proximal contact with proper location and form relationships to prevent forceful interproximal wedging of food, which in turn protects interdental papilla. We performed the procedure using flowable composite resin or composite resin cement with the aid of a cerclage wire under tension to rebuild the contact area. The reported method is especially useful for some challenging clinical cases, such as food impaction after crown and inlay on onlay restoration, and some conventional treatment methods, such as contouring the marginal ridge and developmental grooves, are ineffective.

  2. Atraumatic Restoration of Vertical Food Impaction with an Open Contact Using Flowable Composite Resin Aided by Cerclage Wire under Tension

    Directory of Open Access Journals (Sweden)

    Quan-Li Li

    2016-01-01

    Full Text Available To date, treating vertical food impaction with open contact effectively, especially with an atraumatic therapy, remains a challenge. In this study, we developed a simple, atraumatic, and economic therapeutic measure to treat vertical food impaction. The scientific rationale of our therapeutic technique is to restore an intact and firm proximal contact with proper location and form relationships to prevent forceful interproximal wedging of food, which in turn protects interdental papilla. We performed the procedure using flowable composite resin or composite resin cement with the aid of a cerclage wire under tension to rebuild the contact area. The reported method is especially useful for some challenging clinical cases, such as food impaction after crown and inlay on onlay restoration, and some conventional treatment methods, such as contouring the marginal ridge and developmental grooves, are ineffective.

  3. Atraumatic Restoration of Vertical Food Impaction with an Open Contact Using Flowable Composite Resin Aided by Cerclage Wire under Tension

    Science.gov (United States)

    Ying Cao, Chris; Xu, Qiang-Jian; Xu, Xiao-Hua; Yin, Jia-Li

    2016-01-01

    To date, treating vertical food impaction with open contact effectively, especially with an atraumatic therapy, remains a challenge. In this study, we developed a simple, atraumatic, and economic therapeutic measure to treat vertical food impaction. The scientific rationale of our therapeutic technique is to restore an intact and firm proximal contact with proper location and form relationships to prevent forceful interproximal wedging of food, which in turn protects interdental papilla. We performed the procedure using flowable composite resin or composite resin cement with the aid of a cerclage wire under tension to rebuild the contact area. The reported method is especially useful for some challenging clinical cases, such as food impaction after crown and inlay on onlay restoration, and some conventional treatment methods, such as contouring the marginal ridge and developmental grooves, are ineffective. PMID:27579217

  4. Comparison of Tension-Band Wiring With the Cable Pin System in Patella Fractures: A Randomized Prospective Study.

    Science.gov (United States)

    Tian, Qing-xian; Hai, Yong; Du, Xin-ru; Xu, Zi-yu; Lu, Tie; Shan, Lei; Liu, Yang; Zhou, Jun-lin

    2015-12-01

    To compare the outcome of tension-band wiring (TBW) with the cable pin system (CPS) for transverse fractures of the patella. Randomized prospective study. Academic Level I trauma center. From February 2008 to December 2011, 73 consecutive patients with transverse fractures of the patella were prospectively enrolled in this study. The patients were randomly divided into 2 groups: one group was treated using the CPS, and the other group was treated using the modified TBW. The clinical outcome assessment included analyses of the radiographic images, the modified Hospital for Special Surgery scoring system, and complications. The follow-up time ranged from 12 to 29 months. All fractures healed, with a union rate of 100%. The fracture healing time was significantly shorter in the CPS group (8.51 ± 2.59 weeks, n = 34) compared with the TBW group (11.79 ± 3.04 weeks, n = 39). Postoperative complications in the CPS and TBW groups were observed in 1 and 9 patients, respectively, a difference that was statistically significant. The mean Hospital for Special Surgery score for the CPS group (90.53 ± 5.19 points) was significantly higher than that for the TBW group (81.36 ± 12.71 points). The CPS is a viable option for transverse fractures of the patella and is associated with a shorter healing time, fewer complications, and better function than TBW. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  5. Design considerations for a high-spatial-resolution positron camera with dense-drift-space MWPC's

    Science.gov (United States)

    Delguerra, A.; Perez-Mendez, V.; Schwartz, G.; Nelson, W. R.

    1982-10-01

    A multiplane Positron Camera is proposed, made of six MWPC modules arranged to form the lateral surface of a hexagonal prism. Each module (50 x 50 sq cm) has a 2 cm thick lead-glass tube converter on both sides of a MWPC pressurized to 2 atm. Experimental measurements are presented to show how to reduce the parallax error by determining in which of the two converter layers the photon has interacted. The results of a detailed Monte Carlo calculation for the efficiency of this type of converter are shown to be in excellent agreement with the experimental measurements. The expected performance of the Positron Camera is presented: a true coincidence rate of 56,000 counts/s (with an equal accidental coincidence rate and a 30% Compton scatter contamination) and a spatial resolution better than 5.0 mm (FWHM) for a 400 micron Ci pointlike source embedded in a 10 cm radius water phantom.

  6. Test of a MWPC for the LHCb Muon System at the Gamma Irradiation Facility at CERN

    CERN Document Server

    Anelli, M; Felici, G; Forti, C; Lanfranchi, G; Rosellini, R; Santoni, M; Saputi, A; Sarti, A; Sciascia, B; Bocci, V; Chiodi, G; Dané, E; Iacoangeli, F; Martellotti, G; Nobrega, R; Pinci, D; Rinaldi, W; Gatta, M

    2005-01-01

    We present the results of a test on a MWPC, of the region M3R3 of the LHCb Muon System, at the Gamma Irradiation Facility (GIF) at CERN. This was the first test of a chamber equipped with the final front end electronics. The performance of the chamber was studied with an about 100 GeV muon beam varying, by means of filters, the intensity of the photon flux reaching the detector.

  7. Alpha-beta monitoring system based on pair of simultaneous Multi-Wire Proportional Counters

    Science.gov (United States)

    Wengrowicz, U.; Amidan, D.; Orion, I.

    2016-08-01

    A new approach for a simultaneous alpha-beta Multi-wire Proportional Counter (MWPC) is presented. The popular approach for alpha-beta monitoring systems consists of a large area MWPC using noble gas flow such as Argon Methane. This method of measurement is effective but requires large-scale and expensive maintenance due to the needs of gas flow control and periodic replacements. In this work, a pair of simultaneous MWPCs for alpha-beta measuring is presented. The developed detector consists of a sealed gas MWPC sensor for beta particles, behind a free air alpha sensor. This approach allows effective simultaneous detection and discrimination of both alpha and beta radiation without the maintenance cost noble gas flow required for unsealed detectors.

  8. Alpha–beta monitoring system based on pair of simultaneous Multi-Wire Proportional Counters

    Energy Technology Data Exchange (ETDEWEB)

    Wengrowicz, U.; Amidan, D. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel); NRC-Negev, P.O. Box 9001, Beer-Sheva 84190 (Israel); Orion, I. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel)

    2016-08-11

    A new approach for a simultaneous alpha–beta Multi-wire Proportional Counter (MWPC) is presented. The popular approach for alpha–beta monitoring systems consists of a large area MWPC using noble gas flow such as Argon Methane. This method of measurement is effective but requires large-scale and expensive maintenance due to the needs of gas flow control and periodic replacements. In this work, a pair of simultaneous MWPCs for alpha–beta measuring is presented. The developed detector consists of a sealed gas MWPC sensor for beta particles, behind a free air alpha sensor. This approach allows effective simultaneous detection and discrimination of both alpha and beta radiation without the maintenance cost noble gas flow required for unsealed detectors.

  9. Societal costs in displaced transverse olecranon fractures: using decision analysis tools to find the most cost-effective strategy between tension band wiring and locked plating.

    Science.gov (United States)

    Francis, Tittu; Washington, Travis; Srivastava, Karan; Moutzouros, Vasilios; Makhni, Eric C; Hakeos, William

    2017-09-15

    Tension band wiring (TBW) and locked plating are common treatment options for Mayo IIA olecranon fractures. Clinical trials have shown excellent functional outcomes with both techniques. Although TBW implants are significantly less expensive than a locked olecranon plate, TBW often requires an additional operation for implant removal. To choose the most cost-effective treatment strategy, surgeons must understand how implant costs and return to the operating room influence the most cost-effective strategy. This cost-effective analysis study explored the optimal treatment strategies by using decision analysis tools. An expected-value decision tree was constructed to estimate costs based on the 2 implant choices. Values for critical variables, such as implant removal rate, were obtained from the literature. A Monte Carlo simulation consisting of 100,000 trials was used to incorporate variability in medical costs and implant removal rates. Sensitivity analysis and strategy tables were used to show how different variables influence the most cost-effective strategy. TBW was the most cost-effective strategy, with a cost savings of approximately $1300. TBW was also the dominant strategy by being the most cost-effective solution in 63% of the Monte Carlo trials. Sensitivity analysis identified implant costs for plate fixation and surgical costs for implant removal as the most sensitive parameters influencing the cost-effective strategy. Strategy tables showed the most cost-effective solution as 2 parameters vary simultaneously. TBW is the most cost-effective strategy in treating Mayo IIA olecranon fractures despite a higher rate of return to the operating room. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  10. 锚钉结合张力带钢丝治疗髌骨下极骨折%Suture anchors combined with tension band wiring for inferior polar fracture of the patella

    Institute of Scientific and Technical Information of China (English)

    江潮胤; 徐铮宇; 王韬

    2012-01-01

    Objective To observe the result of treatment of inferior polar fracture of the patella with suture anchors and tension band wiring. Methods Thirty-four patients with inferior polar fracture of the patella were treated with suture anchors and tension band wiring in our hospital between March 2008 and September 2009, The fracture and patellar tendon were fixed and repaired with suture anchors. A stainless steel wire was passed through a transverse hole drilled in the proximal part of the patella and tibial tubercle and tightened as a tension band wiring. Results All the patients were followed up for 12-25 months (average, 17 months) and all the fractures were healed Two patients had shown superficial incisional infection and healed through intravenous antibiotic therapy and dressing change. According to the LU Yu-pu's score of knee function, 27 patients were excellent, 6 patients-were good, 1 patient was fair. The excellent and good rate was 97. 1%. Conclusion Suture anchors combined with tension band wiring for inferior polar fracture of the patella can obtain excellent clinical result with few complications.%目的 研究锚钉结合张力带钢丝治疗髌骨下极骨折的疗效.方法 我院于2008年3月至2009年9月采用锚钉结合张力带钢丝方法治疗髌骨下极骨折34例.术中以锚钉固定修补髌骨下极骨折块及髌韧带,并辅以胫骨结节至髌骨中上部的张力带钢丝.结果 34例患者均获12~25个月,平均17个月随访,所有骨折均愈合,2例术后出现局部浅表感染,经换药及相应抗炎治疗后愈合.陆裕朴膝关节功能评定标准评价显示,优27例,良6例,可1例,优良率为97.1%.结论 锚钉结合张力带钢丝治疗髌骨下极骨折固定牢靠,并发症少,效果确切.

  11. Bending Fatigue Damage Behavior of Bearing Wire Rope on Different Pre-tension%承载钢丝绳在不同预张力下的弯曲疲劳损伤研究

    Institute of Scientific and Technical Information of China (English)

    贾小凡; 张德坤

    2011-01-01

    以6×19+FC点接触式钢丝绳为研究对象,研究钢丝绳在不同预张力下的弯曲疲劳损伤行为,考察不同预张力对弯曲疲劳寿命、损伤量值、外层可见断丝数和钢丝之间的微动磨损的影响,探索其疲劳损伤机制.在自制的钢丝绳弯曲疲劳试验机上开展钢丝绳在不同预张力下的弯曲疲劳试验,采用钢丝绳无损检测仪和人工检测方法分别判定不同预张力下钢丝绳的弯曲疲劳寿命,采用光学显微镜和扫描电镜观察分析钢丝绳的疲劳损伤机制.结果表明,钢丝绳的弯曲疲劳寿命随着预张力的增大而减小,其损伤量值和外层可见断丝数随着弯曲疲劳次数的增加而增大,断丝均发生在外层钢丝与弯曲滑轮磨损严重处,断丝长度有集中现象;其疲劳断裂机理表明,钢丝绳内部钢丝之间的微动磨损亦是影响钢丝绳疲劳寿命的重要因素.%The 6Χ 19+FC point contact rope is taken as the research object to study the bending fatigue behavior of the hoisting rope. The influence of the pre-tension to the bending fatigue life, the damage value and the number of the visible broken wires is investigated to explore the fatigue damage mechanism. The effect of the pre-tension on the bending fatigue behavior is tested by the test carried out on the self-made bending fatigue apparatus. Wire rope nondestructive testing instrument and manual inspection are used to detect the bending fatigue life, respectively. Furthermore, the morphologies of the fatigue damaged steel wire surfaces are observed on the optical electron microscope and the S-3000N scanning electron microscope. The results show that, the damage value and the number of the visible broken wires in the outer layer increase with the increase of pre-tension while the bending fatigue life of the wire rope decrease. The broken wires appear at the position of the outer layer where wear seriously with the bending pulleys. Moreover, broken wires appear

  12. The Application of Constant Tension Wire-barrow in Railway Electrification Construction%恒张力放线车在铁路电气化施工中的应用

    Institute of Scientific and Technical Information of China (English)

    郑淑娟

    2014-01-01

    结合高速铁路电气化施工技术要求,介绍了恒张力放线车结构组成、放线流程、安全保证措施,满足高速铁路电气化施工要求。%Connecting with the technical requirements for high-speed railway’s electrification construction, this paper introduces the structural composition, stringing process and safety-ensuring measures of constant tension wire-barrow for meeting the requirements for high-speed railway’s electrification construction.

  13. 克氏针张力牵引法治疗腱性锤状指畸形%Kirschner wire tension traction for the treatment of tendinous mallet finger deformity

    Institute of Scientific and Technical Information of China (English)

    江波; 张勇; 赵家举; 左志诚; 王培吉

    2016-01-01

    Objective To explore the clinical outcomes of treating tendinous mallet finger deformity with Kirschner wire tension traction.Methods From June 2012 to August 2014,27 patients (27 fingers) with a tendinous mallet finger deformity were treated with Kirschner wire tension traction.Postoperatively a small splint was applied only to protect the extruding K-wires and allowed free movement of the proximal interphalangeal joint and metacarpophalangeal joint.At 6 weeks postoperatively,the K-wires and traction sutures were removed.Active and passive distal interphalangeal joint exercises were initiated immediately afterwards.Results Two patients were lost for follow-up.The rest 25 patients were follow-up for 9 to 16 months postoperatively,with an average of 13 months.According to Crawford's evaluation criteria,the results were excellent in 7 cases,good in 15 cases and fair in 3 cases.The overall good-excellent rate was 88%.Conclusion Kirschner wire tension traction is an effective treatment for tendinous mallet finger.The procedure is simple yet corrects the deformity and results in satisfactory joint motion.%目的 探讨克氏针张力牵引法治疗腱性锤状指畸形的临床疗效.方法 自2012年6月至2014年8月,我们对27例腱性锤状指患者应用克氏针张力牵引法治疗,术后夹板保护克氏针尾端,近指间关节及掌指关节正常活动,6周后拆除牵引线、拔除克氏针.结果 术后2例失访,25例获得随访,随访时间为9~ 16个月,平均13个月.按Crawford锤状指疗效评价体系评估:优7例,良15例,可3例,优良率为88%.结论 采用克氏针张力牵引法固定伸肌腱,手术操作简单,可明显纠正锤状指畸形,获得良好的关节活动度,是治疗锤状指畸形较为有效的方法.

  14. Fast readout of the COMPASS RICH CsI-MWPC chambers

    CERN Document Server

    Abbon, P; Deschampbs, H; Kunne, F; Gerasimov, S; Ketzer, B; Konorov, I; Kravtchuk, N; Magnon, A; Neyret, D; Panebianco, S; Paul, S; Rebourgeard, P; Tessaroto, F

    2006-01-01

    A new readout system for CsI-coated MWPCs, used in the COMPASS RICH detector, has been proposed and tested in nominal high-rate conditions. It is based on the APV25-S1 analog sampling chip, and will replace the Gassiplex chip readout used up to now. The APV chip, originally designed for silicon microstrip detectors, is shown to perform well even with “slow” signals from a MWPC, keeping a signal-to-noise ratio of 9. For every trigger the system reads three consecutive in-time samples, thus allowing to extract information on the signal shape and its timing. The effective time window is reduced from ∼3 μs for the Gassiplex to below 400 ns for the APV25-S1 chip, reducing pile-up events at high particle rate. A significant improvement of the signal-to-background ratio by a factor 5–6 with respect to the original readout has been measured in the central region of the RICH detector. Due to its pipelined architecture, the new readout system also considerably reduces the dead time per event, allowing efficien...

  15. Fast readout of the COMPASS RICH CsI-MWPC photon chambers

    Science.gov (United States)

    Abbon, P.; Delagnes, E.; Deschamps, H.; Kunne, F.; Gerasimov, S.; Ketzer, B.; Konorov, I.; Kravtchuk, N.; Magnon, A.; Neyret, D.; Panebianco, S.; Paul, S.; Rebourgeard, P.; Tessaroto, F.

    2006-11-01

    A new readout system for CsI-coated MWPCs, used in the COMPASS RICH detector, has been proposed and tested in nominal high-rate conditions. It is based on the APV25-S1 analog sampling chip, and will replace the Gassiplex chip readout used up to now. The APV chip, originally designed for silicon microstrip detectors, is shown to perform well even with "slow" signals from a MWPC, keeping a signal-to-noise ratio of 9. For every trigger the system reads three consecutive in-time samples, thus allowing to extract information on the signal shape and its timing. The effective time window is reduced from ˜3 μs for the Gassiplex to below 400 ns for the APV25-S1 chip, reducing pile-up events at high particle rate. A significant improvement of the signal-to-background ratio by a factor 5-6 with respect to the original readout has been measured in the central region of the RICH detector. Due to its pipelined architecture, the new readout system also considerably reduces the dead time per event, allowing efficient data taking at higher trigger rate.

  16. Fast readout of the COMPASS RICH CsI-MWPC photon chambers

    Energy Technology Data Exchange (ETDEWEB)

    Abbon, P. [DSM-DAPNIA, CEA Saclay, route de Saclay, F-91191 Gif-sur-Yvette (France); Delagnes, E. [DSM-DAPNIA, CEA Saclay, route de Saclay, F-91191 Gif-sur-Yvette (France); Deschamps, H. [DSM-DAPNIA, CEA Saclay, route de Saclay, F-91191 Gif-sur-Yvette (France); Kunne, F. [DSM-DAPNIA, CEA Saclay, route de Saclay, F-91191 Gif-sur-Yvette (France); Gerasimov, S. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Ketzer, B. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Konorov, I. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Kravtchuk, N. [JINR Dubna, 141980 Dubna (Russian Federation); Magnon, A. [DSM-DAPNIA, CEA Saclay, route de Saclay, F-91191 Gif-sur-Yvette (France); Neyret, D. [DSM-DAPNIA, CEA Saclay, route de Saclay, F-91191 Gif-sur-Yvette (France)]. E-mail: damien.neyret@cern.ch; Panebianco, S. [DSM-DAPNIA, CEA Saclay, route de Saclay, F-91191 Gif-sur-Yvette (France); Paul, S. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Rebourgeard, P. [DSM-DAPNIA, CEA Saclay, route de Saclay, F-91191 Gif-sur-Yvette (France); Tessaroto, F. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy)

    2006-11-01

    A new readout system for CsI-coated MWPCs, used in the COMPASS RICH detector, has been proposed and tested in nominal high-rate conditions. It is based on the APV25-S1 analog sampling chip, and will replace the Gassiplex chip readout used up to now. The APV chip, originally designed for silicon microstrip detectors, is shown to perform well even with 'slow' signals from a MWPC, keeping a signal-to-noise ratio of 9. For every trigger the system reads three consecutive in-time samples, thus allowing to extract information on the signal shape and its timing. The effective time window is reduced from {approx}3 {mu}s for the Gassiplex to below 400 ns for the APV25-S1 chip, reducing pile-up events at high particle rate. A significant improvement of the signal-to-background ratio by a factor 5-6 with respect to the original readout has been measured in the central region of the RICH detector. Due to its pipelined architecture, the new readout system also considerably reduces the dead time per event, allowing efficient data taking at higher trigger rate.

  17. Corrosion Induced Loss of Capacity of Post Tensioned Seven Wire Strand Cable Used in Multistrand Anchor Systems Installed at Corps Projects

    Science.gov (United States)

    2016-12-01

    White, James A. Evans, Richard W. Haskins, and Ernest L. Miller December 2016 Approved for public release; distribution is unlimited. The...Robert M. Ebeling, Barry C. White, James A. Evans, Richard W. Haskins, and Ernest L. Miller Information Technology Laboratory U.S. Army Engineer...2014). .......................... 81 Figure 6.14. Probability-density plot from Darmawan and Stewart (2007) equations for Table 6.7 Wire 2 properties

  18. Front-end Electronics Test for the LHCb Muon Wire Chambers

    CERN Document Server

    Nobrega, R; Carboni, G; Massafferri, A; Santovetti, E

    2007-01-01

    This document describes the apparatus and procedures implemented to test Multi Wire Proportional Chambers (MWPC) after front-end assembly for the LHCb Muon Detector. Results of measurements of key noise parameters are also described. Given a fully equipped chamber, this system is able to diagnose every channel performing an analysis of front-end output drivers’ response and noise rate versus threshold. Besides, it allows to assess if the noise rate at the experiment threshold region is within appropriate limits. Aiming at an automatic, fast and user-friendly system for mass production tests of MWPC, the project has foreseen as well electronic identification of every chamber and front-end board, and data archiving in such a way to make it available to the Experiment Control System (ECS) while in operation.

  19. The influence of a weight-bearing platform on the mechanical behavior of two Ilizarov ring fixators: tensioned wires vs. half-pins

    Directory of Open Access Journals (Sweden)

    Gessmann Jan

    2011-12-01

    Full Text Available Abstract Background A weight-bearing platform applied at the distal end of an Ilizarov external frame allows patients with hindfoot transfixations, foot deformities or plantar skin lesions to bear weight. This leads to an indirect loading of the fracture or osteotomy site. However, the effect on the fracture/osteotomy site's motion or compressive loads is unknown. The aim of this study was to analyze the mechanical effects of a weight-bearing platform on the traditional all-wire, four-ring frame in comparison to a two-ring frame consisting of half-pins. Methods Two frame configurations, with either anatomically positioned wires or half-pins, were analyzed with and without a weight-bearing platform applied underneath the distal ring. Composite tibiae with a mid-diaphyseal osteotomy of 3.5 mm were used in all the experiments. An axial load was applied with the use of a universal test machine (UTS®. Interfragmentary movements, the relative movements of bone fragments and movements between rings were recorded using displacement transducers. Compressive loads at the osteotomy site were recorded with loading cells. Results Indirect loading with a weight-bearing platform altered the force transmission through the osteotomy. Indirect loading of the tibiae decreased the extent of the axial micro-motion by 50% under the applied weight load when compared to direct weight loading (p Conclusions A weight-bearing platform has substantial influence on the biomechanical performance of an Ilizarov external fixator. Half-pins induce greater stiffness to the Ilizarov external fixator and allow the usage of only one ring per bone segment, but shear stresses at the osteotomy under axial loading should be considered. The results allow an estimation of the size and direction of interfragmentary movements based on the extent of weight bearing.

  20. Isolated olecranon fractures in children affected by osteogenesis imperfecta type I treated with single screw or tension band wiring system: Outcomes and pitfalls in relation to bone mineral density.

    Science.gov (United States)

    Persiani, Pietro; Ranaldi, Filippo M; Graci, Jole; De Cristo, Claudia; Zambrano, Anna; D'Eufemia, Patrizia; Martini, Lorena; Villani, Ciro

    2017-05-01

    The purpose of this study is to compare the results of 2 techniques, tension band wiring (TBW) and fixation with screws, in olecranon fractures in children affected with osteogenesis imperfecta (OI) type I. Between 2010 and 2014, 21 olecranon fractures in 18 children with OI (average age: 12 years old) were treated surgically. Ten patients were treated with the screw fixation and 11 with TBW. A total of 65% of olecranon fractures occurred as a result of a spontaneous avulsion of the olecranon during the contraction of the triceps muscle. The average follow-up was 36 months. Among the children treated with 1 screw, 5 patients needed a surgical revision with TBW due to a mobilization of the screw. In this group, the satisfactory results were 50%. In patients treated with TBW, the satisfactory results were 100% of the cases. The average Z-score, the last one recorded in the patients before the trauma, was -2.53 in patients treated with screw fixation and -2.04 in those treated with TBW. TBW represents the safest surgical treatment for patients suffering from OI type I, as it helps to prevent the rigidity of the elbow through an earlier recovery of the range of motion, and there was no loosening of the implant. In analyzing the average Z-score before any fracture, the fixation with screws has an increased risk of failure in combination with low bone mineral density.

  1. Readout of the time signals of the MWPC detector with boron sensitive thermal neutron%新型涂硼热中子 MWPC 探测器的时间信号读出方法

    Institute of Scientific and Technical Information of China (English)

    杨波; 曹平; 孙维佳; 张莹; 安琪; 陈波

    2016-01-01

    The two dimensional sensitive detector based on 1 0 B film is a newly developed thermal neutron detector with the advantages of large sensitive area,good time and position resolution,high n/γ inhibition ability,strong ability of anti-radiation, two-dimensional readout and good resistance to the count rate capability.So it is important to carry out the study of the readout method of the two-dimensional position sensitive neutron detector based on the B neutron transfer layer and MWPC structure.In this paper,a readout board based on delay-line readout method is presented.By measuring the time difference between the arri-ving signals on both sides of delay-line,the original position can be well recovered.By applying a hardwire filter in FPGA,the da-ta rate needs to be transferred can be reduced remarkably.The RMS of the TDC is less than 50 ps.The integral nonlinearity is better than 1.1 LSB,the differential non-linearity is better than 0.5 LSB.The board achieves event rates of 1.3 MHz for periodic signals and the data can be transferred by Gbit ethernet daughter board simultaneously.%基于10 B 薄膜的二维灵敏探测器是新近发展起来的热中子探测器,其灵敏面积大,时间和位置分辨好,n/γ抑制能力高,抗辐射能力强,可二维读出且具有良好的耐计数能力。针对新型的涂硼灵敏热中子多丝正比(MWPC)探测器,在延迟线时间差方法的基础上,提出一种中子击中位置数字信息的读出方法,并设计 NIM 读出插件用以验证该方法对于二维中子探测位置信息的读出能力。测试结果表明,本方法能完成4通道探测器信号的实时测量,其时间测量精度好于50 ps。结合 FPGA 片上系统实时数据控制和处理技术,单插件可支持最高1.3MHz 的探测计数率。

  2. A progressive reduce tension method to fabricate Bradbury-Nielsen gates with uniform tension

    CERN Document Server

    Kai, Ni; Zhou, Yu

    2015-01-01

    Bradbury-Nielsen gates (BNG) which consist of two interleaved and electrically isolated sets of wires can be used to modulate the beams of charged particles, particularly ion beams in mass spectrometry and ion mobility spectrometry. The wires of BNG with uniform tension is critical to make sure the BNG work reliable and robust. In our previous work, we have analyzed the problem of wires tension non-uniform that exists in the traditional sequentially winding methods when the metal wire's elastic modulus is much larger than insulations substrate's and developed a template-based transfer method to solve this problem. In this study, we proposed a progressive reduce tension method which does not need template to fabricate BNG with uniform tension. First input the initial parameters to calculate the final progressive reduce tension sequence (FA(i)) through program; then sequentially adjust the weight set according to FA(i) to construct a BNG with uniform tension wires through a home-built device. Wires tension non-...

  3. Percutaneous AO Kirschner wire plus tension band wire fixation for patella closed transverse fracture%经皮穿刺克氏针加张力带钢丝固定治疗闭合性髌骨横断骨折

    Institute of Scientific and Technical Information of China (English)

    赵斌修; 王坤正

    2007-01-01

    手术方法具有创伤小、恢复快及术区美观等特点,并能允许膝关节早期活动,临床疗效满意.%BACKGROUND: Tension band suture fixation is always used in treating patellar fracture, and its modified method of Kirschner wire plus tension band steel-wire is also widely applied. But because the traditional surgery always causes massive incision and scar formation, it affects the appearance and function of knee joint.OBJECTIVE: To investigate the clinical curative effect of percutaneous puncture plus tension zone steel-wire fixation for the treatment of patella closed transverse fracture.DESIGN: Retrospective analysis:SETTING: Second Hospital of Medical College, Xi'an Jiaotong University.PARTICIPANTS: Twenty-nine patients with closed patellar transverse fracture admitted by Department of Orthopedics,Medical College of Xi'an Jiaotong University were selected from an average age of 36 years old. Only people that were diagnosed by X-ray as closed patellar transverse fracture were enrolled, and the informed consent was obtained from them.jostled until resetting, and then the fractured pieces were clamped by a clavical clamp to fix. Two incisions were made at the upper and lower ends of patella, and two were penetrated from the incision until its tip out of the lower hole of the same Kirschner wire under skin. The soft steel wire was drawn tightly and bended along the tip of Kirschner wire. The three-grading method, and the recovery of patients in 4 years after operation was evaluated according to the composite evaluation means about the knee joint established by Xu et al (pain, movement range of knee joint and reset of the fracture in patellar face. Meanwhile, the postoperative complications were observed.MAIN OUTCOME MEASURES: Wound healing, postoperative functional recovery and complications of patients.cases scored in grade 1, accounted for 93%, 2 cases in grade 2, accounted for 7%, who were recovered after change of means about the knee joint

  4. Development of Intercalated Wire and Cable.

    Science.gov (United States)

    1984-02-01

    size because of longitudinal splitting. Attempts have been made to 2 substitute wire drawing for the swaging (7) but these have been unsuccessful. It...appears that the radial pressure of the swaging may be an essential ingredient to the process and that the longitudinal tension of wire drawing causes...conductivity. It is possible that the high pressures encountered in swaging as opposed to wire drawing , for instance, are a significant factor. High

  5. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  6. wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  7. Analysis of 23 cases of avulsion fractures of posterior cruciate ligament of knee joint treated by tension band wire fixation%张力带钢丝固定治疗膝关节后交叉韧带止点撕脱骨折23例分析

    Institute of Scientific and Technical Information of China (English)

    张朝凯; 吴莉; 丁晶; 刘庆波; 李迎辉; 吴明贵; 俞超

    2013-01-01

    目的 探讨张力带钢丝固定治疗膝关节后交叉韧带止点撕脱骨折的效果.方法 23例膝关节后交叉韧带止点撕脱骨折患者,采用张力带钢丝复位固定,并对关节腔进行修整;采用Lysholm膝关节评分法评价疗效.结果 23例患者随访6个月~2年,22例(95.7%)术后膝关节功能恢复良好,1例老年患者术前即有骨性关节炎,关节间隙狭窄,术后仍有慢性疼痛及曲伸功能障碍.结论 张力带钢丝固定治疗膝关节后交叉韧带止点撕脱骨折简单、经济、有效.%Objective To investigate the outcomes of avulsion fractures of posterior cruciate ligament of knee joint treated by tension band wire fixation. Methods Twenty-three patients with avulsion fractures of posterior cruciate ligament of knee joint were treated with tension band wire fixation, and the outcomes were evaluated by Lysholm knee joint scoring. Results All the patients were followed up for 6 months to 2 years. Favorable function recovery was achieved in 22 (95.7%) patients. The other senior patient suffered from osteoarthritis and narrow joint space before operation, and there still existed chronic pain and flexion-extension dysfunction after operation. Conclusion Treatment of avulsion fractures of posterior cruciate ligament of knee joint by tension band wire fixation is simple, economical and effective.

  8. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  9. 钢丝张力带联合空心拉力螺钉治疗髌骨骨折的临床探析%Clinical Study on Wire Tension Band Combined with Hollow Lag Screw in Treatment of Patellar Fracture

    Institute of Scientific and Technical Information of China (English)

    李久岩

    2015-01-01

    Objective To explore clinical efficacy of wire tension band combined with hol ow lag screw treatment of patel ar fracture. Methods Choose 40 patients with patel ar fracture who are treated in hospital from July 2013 to July 2014 and separate them into study group and control group according to different treatment approaches. Patients in control group are given wire tension band treatment,while patients in study group are given wire tension band combined with hol ow lag screw treatment;and then observe and compare the treatment efficacy of these two groups. Results Compared to control group,patients’recovery time in study group is shorter than that in control group,besides,the treatment efficacy in study group is much higher than that in control group; there is a treatment differential between the two groups,and such a differential has statistic value(P<0.05). Conclusion Wire tension band combined with hol ow lag screw is of efficacy in treatment of patel ar fracture,which is quite worthwhile to be promoted and applied clinical y.%目的:探究钢丝张力带联合空心拉力螺钉治疗髌骨骨折的临床疗效。方法搜集2013年7月~2014年7月我院接收的髌骨骨折40例患者,按照治疗方法不同进行分组。即对照组(钢丝张力带)和实验组(钢丝张力带联合空心拉力螺钉)。观察并比较两组疗效。结果与对照组相比,实验组骨折愈合时间较短,治疗有效率较高,有明显差异,有统计学意义(P<0.05)。结论钢丝张力带联合空心拉力螺钉治疗髌骨骨折的临床疗效显著,可推广。

  10. Patellar ring pins and FiberWire braided polyblend sutures tension band fixation for the treatment of patellar fracture%髌骨针和FiberWire编织缝线张力带联合固定治疗髌骨骨折

    Institute of Scientific and Technical Information of China (English)

    黄奎; 刘克斌

    2013-01-01

    背景:克氏针钢丝张力带是治疗髌骨骨折最常见的方式,但易引起与金属植入物相关的并发症。基于上述原因,有学者开始在张力带固定中应用高强度缝线替代钢丝固定来治疗髌骨骨折。目的:观察髌骨针和FiberWire编织缝线张力带联合固定治疗髌骨骨折的效果。方法:对髌骨针和FiberWire编织缝线张力带固定治疗26例髌骨骨折患者的资料进行回顾性分析,其中男16例,女10例;年龄36-54岁,平均44.6岁。结果与结论:随访6-18个月,平均12个月。所有患者切口均一期愈合。骨折愈合时间为8-16周,平均12周。无骨折移位,无固定松动、断裂或突出于皮下刺激皮肤等并发症发生。按Lysholm&Gil quist 膝关节评分标准评定,优18例,良4例,可4例,优良率85%。结果可见应用髌骨针和FiberWire编织缝线张力带固定治疗髌骨骨折达到了满意的结果,且并发症少。%BACKGROUND:K-wire and steel wire tension band wiring is the most commonly method for the treatment of patel ar fracture. However, there have been many reports of complications related to the mental implants. Based on the reasons above, some scholars begin to replace the steel wire with braided polyester sutures for the treatment of patel ar fracture. OBJECTIVE:To observe the effect of patel ar ring pins and FiberWire braided polyblend sutures tension band fixation for treatment of patel ar fracture. METHODS:We performed a retrospective analysis involving 26 patients with patel ar fracture (16 males, 10 females, at the age of 36-54 years with a mean age of 44.6 years) who were treated with patel ar ring pins and FiberWire braided polyblend sutures tension band fixation. RESULTS AND CONCLUSION:Al the patients were fol owed-up for 6-18 months, average of 12 months. Al patients were primary healing and achieved bone union in 8-16 weeks, averaged in 12 weeks from surgery. There was no fracture fragment

  11. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  12. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  14. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  15. Particle tracking in kaon electroproduction with cathode-charge sampling in multi-wire proportional chambers

    CERN Document Server

    Achenbach, P; Bernauer, J C; Böhm, R; Bosnar, D; Bösz, M; Debenjak, L; Distler, M O; Esser, A; Friščić, I; de la Paz, M Gómez Rodríguez; Makek, M; Merkel, H; Müller, U; Nungesser, L; Pochodzalla, J; Potokar, M; Majos, S Sánchez; Schlimme, B S; Širca, S; Weinriefer, M; 10.1016/j.nima.2011.03.039

    2011-01-01

    Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the background rate in the chambers. One way to determine the track of a charged particle through a multi-wire proportional chamber (MWPC) is the measurement of the charge distribution induced on its cathodes. In practical applications of this read-out method, the algorithm to relate the measured charge distribution to the avalanche position is an important factor for the achievable position resolution and for the track reconstruction efficiency. An algorithm was developed for operating two large-sized MWPCs in a strong background environment with multiple-particle tracks. Resulting efficiencies were determined as a function of the electron beam current and on the signal amplitudes. Because of the different energy-losses of pions, kaons, and protons in the momentum range of the s...

  16. First results of an aging test of a full scale MWPC prototype for the LHCb muon system

    CERN Document Server

    Souvorov, V; Schmidt, B; Riegler, Werner; Kashchuk, A; Hutchcroft, D E

    2003-01-01

    Aging studies for a multi-wire proportional chamber of the LHCb muon system have been performed using the CERN Gamma Irradiation Facility. The irradiated four-gap chamber corresponds to a full-size prototype with 1500 cm**2 sensitive area and has been operated with an Ar/CO //2/CF//4 (40:50:10) gas mixture. A linear charge of 0.25 C/cm for 100 m anode wire length has been accumulated over a period of 6 months, which corresponds to the charge collected in 5 LHCb years. The observed aging effects do not prohibit the use of these chambers in the LHCb experiment.

  17. Clinical Analysis of Tension Band Internal Fixation Screw Combined with Cannulated Titanium Wire Treatment of Patella Fracture%空心加压螺纹钉结合钛丝张力带法内固定治疗髌骨骨折临床探讨

    Institute of Scientific and Technical Information of China (English)

    陈哲

    2015-01-01

    Objective To hol ow compression screw nail combining with titanium wire internal fixation treatment of patel a fracture with tension band method shal be discussed in this paper.Methods Selected from October 2011to October 2014 were 31 cases of patel ar fracture patients,using hol ow compression screw nails with internal fixation with titanium wire tension band method to treatment, the treatment ef ect analysis.Results Al patients were successful y completed surgery,no looseness or breakage implants,knee function and basic returned to normal.Conclusion The treatment in patients with patel ar fracture,hol ow compression screw nails in combination with the use of internal fixation with titanium wire tension band method,fixed ef ect is good,can be as early as possible for knee joint function in patients with postoperative exercise,is a bet er treatment method.%目的对空心加压螺纹钉结合钛丝张力带法内固定治疗髌骨骨折予以探讨。方法选取我院2011年10月~2014年10月收治的31例髌骨骨折患者,采用空心加压螺纹钉结合钛丝张力带法内固定予以治疗,对治疗效果予以分析。结果所有患者均顺利完成手术,植入物无松动或断裂,膝关节功能也基本恢复正常。结论对髌骨骨折患者予以治疗时,空心加压螺纹钉结合钛丝张力带法内固定的运用,固定效果较好,术后患者可以尽早进行膝关节功能锻炼,是一种较好的治疗方法。

  18. Tension Structure

    Science.gov (United States)

    1978-01-01

    The fabric structure pictured is the Campus Center of La Verne College, La Verne, California. Unlike the facilities shown on the preceding pages, it is not air-supported. It is a "tension structure," its multi-coned fabric membrane supported by a network of cables attached to steel columns which function like circus tent poles. The spider-web in the accompanying photo is a computer graph of the tension pattern. The designers, Geiger-Berger Associates PC, of New York City, conducted lengthy computer analysis to determine the the best placement of columns and cables. The firm also served as structural engineering consultant on the Pontiac Silverdome and a number of other large fabric structures. Built by Birdair Structures, Inc., Buffalo, New York, the La Verne Campus Center was the first permanent facility in the United States enclosed by the space-spinoff fabric made of Owens-Corning Beta fiber glass coated with Du Pont Teflon TFE. The flexible design permits rearrangement of the interior to accommodate athletic events, student activities, theatrical productions and other recreational programs. Use of fabric covering reduced building cost 30 percent below conventional construction.

  19. Finite element analysis on the wire breaking rule of 1×7IWS steel wire rope

    Directory of Open Access Journals (Sweden)

    Wenzheng Du

    2017-01-01

    Full Text Available Taking the wire rope of 1×7+IWS structure as the research object, the influences of the number of broken wires on the stress distribution under the same axial load were simulated and analysed, and it also explored the rule of wire breaking of steel wire ropes. Based on the SolidWorks software, the three-dimensional model of the wire rope was established. Importing the model into the ABAQUS, the finite element model of the steel wire rope was established. Firstly 5000 N axial tension was placed on the rope, the stress distribution was simulated and analysed, and the steel wire with the largest stress distribution was found out. Then one steel wire was truncated with the load unchanged, and the finite element simulation was carried out again, and repeated the steps several times. The results show that, with the increase of the number of broken wires, the Von-Mises stress of the wire rope increases sharply, and the stress distribution is concentrated on the rest of the unbroken wires, which brings great challenges to the safety of the wire rope.

  20. Research regarding stiffness optimization of wires used for joints actuation from an elephant's trunk robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-11-01

    Elephant's trunk robotic arms driven by wires and pulley mechanisms have issues with wires stiffness because of the entailed elastic deformations that is causing errors of positioning. Static and dynamic loads from each joint of the robotic arm affect the stiffness of driving wires and precision positioning. The influence of wires elastic deformation on precision positioning decreases with the increasing of wires stiffness by using different pre-tensioning devices. In this paper, we analyze the variation of driving wires stiffness particularly to each wire driven joint. We obtain optimum wires stiffness variation by using an analytical method that highlights the efficiency of pre-tensioning mechanism. The analysis of driving wires stiffness is necessary for taking appropriate optimization measures of robotic arm dynamic behavior and, thus, for decreasing positioning errors of the elephant's trunk robotic arm with inner actuation through wires/cables.

  1. Multi responses optimization of wire EDM process parameters using ...

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology .... considering input parameters peak current, pulse on time, pulse off time & wire tension for En31 tool steel ..... International Journal of Multidisciplinary and Current Research Vol.

  2. Position reconstruction in fission fragment detection using the low pressure MWPC technique for the JLab experiment E02-017

    Energy Technology Data Exchange (ETDEWEB)

    Xi-Yu, Qiu [Lanzhou U.; Tang, Liguang [JLAB; Margaryan, Amur T. [Yerevan; Jin-Zhang, Xu [Lanzhou; Bi-Tao, Hu [Lanzhou; Xi-Meng, Chen [Lanzhou

    2014-07-01

    When a lambda hyperon was embedded in a nucleus, it can form a hypernucleus. The lifetime and its mass dependence of stable hypernuclei provide information about the weak decay of lambda hyperon inside nuclear medium. This work will introduce the Jefferson Lab experiment (E02-017) which aims to study the lifetime of the heavy hypernuclei using a specially developed fission fragment detection technique, a multi-wire proportional chamber operated under low gas pressure (LPMWPC). Presented here are the method and performance of the reconstruction of fission position on the target foil, the separation of target materials at different regions and the comparison and verification with the Mote Carlo simulation.

  3. Material Properties of Wire for the Fabrication of Knotted Fences

    Directory of Open Access Journals (Sweden)

    Dirk J. Pons

    2014-01-01

    Full Text Available This paper describes the materials properties of galvanised fencing wire, as used in the fabrication of knotted wire fences. A range of physical properties are investigated: tensile strength, ductility in tension, Young’s modulus, three-point bending, and bending span. A range of commercially available wire products were tested. The results show that most, but not all, high tensile wire samples met the minimum tensile and ductility requirements. Young’s modulus results failed to provide any meaningful insights into wire quality. Flexural modulus results also failed to provide any insight into wire quality issues, with no statistically significant differences existing between acceptable and problematic wire batches. The implications are that premature fence failures are unlikely to be caused solely by reduced tensile properties. Existing test methods, including tensile strength and ductility, are somewhat incomplete, perhaps even unreliable, as measures of wire quality.

  4. 可调式髌骨爪结合可吸收线与克氏针钢丝张力带修复粉碎性髌骨骨折的比较%Adjustable patella claws and absorbable sutureversus Kirschner wire tension band in the repair of comminuted patellar fractures

    Institute of Scientific and Technical Information of China (English)

    崔海峰

    2015-01-01

    BACKGROUND:High-energy patelar comminuted fracture significantly increased. Single fixation cannot meet the requirement of anatomical repositioning of the patela, multiple-point strong fixation, and early functional exercise. OBJECTIVE:To compare the clinical effect of adjustable patela claws + absorbable suture and Kirschner wire tension band in the repair of comminuted patelar fractures. METHODS: A total of 57 patients with comminuted patela fracture were randomly selected and randomly assigned to two groups. 29 cases received open reduction and adjustable patela claws + absorbable suture fixation. 28 cases received open reduction and Kirschner wire tension band fixation. Operative time, incision length, fracture healing time, postoperative complications and Hospital for Special Surgery knee function scores were compared between the two groups, and then statistical analysis was conducted. RESULTS AND CONCLUSION:No significant difference in incision length and operative time was detected between the adjustable patela claws + absorbable suture group and Kirschner wire tension band group. Significant differences in healing time, incidence of complications and knee function after treatment were observed between the two groups, and above indications were better in the adjustable patela claws + absorbable suture group than in the Kirschner wire tension band group (P < 0.05). These results confirm that compared with the Kirschner wire tension band, adjustable patela claws + absorbable suture in repair of patelar comminuted fracture has some advantages such as short healing time, less postoperative complications, as wel as good functional recovery of knee joint. The fixation is accorded with biomechanical principle of internal fixation, simple to operate, firmly fixed, and has good prospects.%背景:高能量下髌骨粉碎性骨折明显增多,单一的内固定已无法满足髌骨解剖复位、多点坚强固定及早期功能锻炼的要求。目的:比较

  5. Wire Chamber

    CERN Multimedia

    1986-01-01

    Two wire chambers made originally for the R807 Experiment at CERN's Intersecting Storage Rings. In 1986 they were used for the PS 201 experiment (Obelix Experiment) at LEAR, the Low Energy Antiproton Ring. The group of researchers from Turin, using the chambers at that time, changed the acquisition system using for the first time 8 bit (10 bit non linear) analog to digital conversion for incoming signals from the chambers. The acquisition system was controlled by 54 CPU and 80 digital signal processors. The power required for all the electronics was 40 kW. For the period, this system was one of the most powerful on-line apparatus in the world. The Obelix Experiment was closed in 1996. To find more about how a wire chamber works, see the description for object CERN-OBJ-DE-038.

  6. 克氏针张力带与髌骨爪内固定治疗髌骨下极骨折的疗效比较%Effect of Kirschner tension-band wire and memory alloy patellar holder in treating inferior polar fracture of patella

    Institute of Scientific and Technical Information of China (English)

    陈文学; 齐越峰; 谢克波; 郑移兵

    2013-01-01

    Objective To compare the therapeutic effects of Kirschner tension-band wire and memory alloy patellar holder in the treatment of inferior polar fracture of patella.Methods All 92 patients with inferior polar fracture of patella treated with Kirschner tension-band wire or memory alloy patellar holder were selected.Of 92 patients,53 cases suffered Kirschner tension-band wire including 45 cases with comminuted fractures,39 cases underwent memory alloy patellar holder including 35 cases with comminuted fractures.All cases were performed surgical reduction and internal fixation under spinal anesthesia.The results were analyzed based on their surgical duration,fracture healing time,postoperative effects,complication rate and cost of hospitalization.Results Patients were followed up for 6 to 18 months,with an average of (11.5 ± 1.0) months.①) For patients with non-comminuted fracture,there was no significant difference between two groups in terms of surgical duration,fracture healing time,the hospital costs (excluding cost for surgical materials),the incidence rate of complication and postoperative effects (P > 0.05).Patients with patellar holder had a lower rate of complication (P < 0.05).There was significant difference in average total hospital costs between patients with patellar holder and patients with Kirschner tension-band wire [(7148 ± 155)yuan vs (5490 ± 129)yuan,P < 0.01].(②) For patients with comminuted fracture,there was no significant difference in fracture healing time between two groups (P > 0.05),but there was significant difference in terms of the curative effect [100.0% (35/35) vs 91.1% (41/45),P < 0.05].For patients with Kirschner tensionband wire,the surgical duration and rate of complications were significantly higher than those in the other group [(63.6 ± 2.5) min vs(48.3 ± 2.2) min,8.9% (4/45) vs 0.0%,P < 0.05 or P < 0.01].There was a significant difference in average total hospital costs between patients with

  7. Skin tension related to tension reduction sutures.

    Science.gov (United States)

    Hwang, Kun; Kim, Han Joon; Kim, Kyung Yong; Han, Seung Ho; Hwang, Se Jin

    2015-01-01

    The aim of this study was to compare the skin tension of several fascial/subcutaneous tensile reduction sutures. Six upper limbs and 8 lower limbs of 4 fresh cadavers were used. At the deltoid area (10 cm below the palpable acromion) and lateral thigh (midpoint from the palpable greater trochanter to the lateral border of the patella), and within a 3 × 6-cm fusiform area of skin, subcutaneous tissue defects were created. At the midpoint of the defect, a no. 5 silk suture was passed through the dermis at a 5-mm margin of the defect, and the defect was approximated. The initial tension to approximate the margins was measured using a tensiometer.The tension needed to approximate skin without any tension reduction suture (S) was 6.5 ± 4.6 N (Newton). The tensions needed to approximate superficial fascia (SF) and deep fascia (DF) were 7.8 ± 3.4 N and 10.3 ± 5.1 N, respectively. The tension needed to approximate the skin after approximating the SF was 4.1 ± 3.4 N. The tension needed to approximate the skin after approximating the DF was 4.9 ± 4.0 N. The tension reduction effect of approximating the SF was 38.8 ± 16.4% (2.4 ± 1.5 N, P = 0.000 [ANOVA, Scheffé]). The tension reduction effect of approximating the DF was 25.2% ± 21.9% (1.5 ± 1.4 N, P = 0.001 [ANOVA, Scheffé]). The reason for this is thought to be that the SF is located closely to the skin unlike the DF. The results of this study might be a basis for tension reduction sutures.

  8. 30 CFR 75.1003 - Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley...

    Science.gov (United States)

    2010-07-01

    ... wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 75.1003 Section 75.1003... Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. Trolley wires, trolley feeder wires, and bare signal wires shall be insulated...

  9. Cable-Pin系统微创与切开复位克氏针张力带修复髌骨横行骨折:随机对照%Cable-Pin System minimally invasive treatmentversus open reduction and Kirschner wire tension band technology for the repair of transverse patella fractures:a randomized controlled trial

    Institute of Scientific and Technical Information of China (English)

    江永良; 卢春闻; 吴云刚; 吴锦辉; 丁慕晨; 吕润潇; 康凯; 毛宁方

    2015-01-01

    BACKGROUND:Open reduction and Kirschner wire tension band technique has been a traditional surgical method for the treatment of patela fracture. However, there stil exist some complications such as Kirschner wire slippage and breakage. Cable-Pin system is a new fixation device. A series of good clinical results has been achieved in patients with patela fracture using this fixation device through a minimaly invasive way. OBJECTIVE:To compare and investigate the clinical results of minimaly invasive fixation with Cable-Pin system and Kirschner wire tension band technique for patela fracture and the complications. METHODS:Eighty patients with radiology-confirmed transverse displacement of patela participated in this trial, and were randomly divided into two groups. Forty patients underwent a minimaly invasive technique and the others had conventional open surgery using Kirschner wire. At postoperative intervals of 1, 3, 6, 12, and 24 months, pain was measured by Visual Analogue Scale scores, range of motion was measured by goniometry, and knee function was evaluated using the Bostman clinical grading scale. RESULTS AND CONCLUSION: Easement of pain was better in the minimaly invasive surgery group than in the control group at 1 and 3 months after treatment (P < 0.05). Above dominance disappeared at 6 months after treatment. At 3-24 months, the knee flexion training was faster and flexion angle was greater in the minimaly invasive surgery group, and results were significantly better than in the control group (P < 0.05). The incidence of discomfort fixation-induced complications was lower in the minimaly invasive surgery group than in the conventional open surgery group (P < 0.05). These data confirm that after minimaly invasive fixation with Cable-Pin system, pain was noticeably lessened, range of motion of affected knee was great, the recovery of knee function was better, the incidence of complications was reduced, and the repair effect was better than the

  10. Development of rolling mill for rectangular orthodontic wires production

    Directory of Open Access Journals (Sweden)

    G.E. Totten

    2007-09-01

    Full Text Available Purpose: In orthodontic treatments, wires of different metallic alloys are used for alignment, leveling, correction of the molar position, space closing, finish and retention. The purpose of the paper is the characteristics of austenitic stainless steel wires, with a square traverse section, which were produced using a rolling mill built for this purpose, are presented hereDesign/methodology/approach: With respect to finish and retention, these wires are responsible for adequate positioning of the upper teeth on the lower teeth. Wires that are subjected to incisor torque require high resistance and stiffness. For this, wires of rectangular austenitic stainless steel are used due to high modulus of elasticity and good corrosion resistance in the oral environment. Because of the rectangular geometry, wire production requires process development suitable for industrial scale manufacture with geometric characteristics and mechanical properties better adapted to the use conditions.Findings: To obtain wires with such characteristics, a rolling mill was developed for the production of rectangular wires by a rolling process with the objective of reducing cost of the cold drawing process that is currently used which utilize complex and expensive wire-drawing dies. In addition to the rolling process itself, wire deformation, microhardness, tension and bend tests were also performed.Research limitations/implications: A rolling-mill was built that successfully produced dental wires within acceptable tolerances and physical/mechanical properties.These wires exhibited excellent hardness and tensile strength, although slightly less than analogous commercial wires. It is expected that this problem are corrected by using initial wires with a higher hardness, since this property is directly related with the tensile strength.Originality/value: In these tests, wire geometry, surface finish and mechanical properties were successfully adapted for use in orthodontic

  11. Damage Prediction Using Several Types of Macro-scale Damage Models in Different Cold Wire Production Lines

    OpenAIRE

    Cao, Trong-Son; Montmitonnet, Pierre; Bouchard, Pierre-Olivier; Bobadilla, Christian; Vachey, Christophe

    2014-01-01

    International audience; The purpose of the present paper is to show how and to what extent the introduction of refined, shear sensitive models improves on previous ones, based on triaxiality only, for the phenomenological description of ductile damage in bulk cold metal forming processes. Wire-drawing and wire rolling are taken as examples. A set of mechanical tests has been conducted: round bar tension, notched bar tension, plane strain tension, and torsion for pure shear deformation. Both c...

  12. A progressively reduced pretension method to fabricate Bradbury-Nielsen gates with uniform tension

    Science.gov (United States)

    Ni, Kai; Guo, Jingran; Yu, Zhou; Cao, Like; Yu, Quan; Qian, Xiang; Wang, Xiaohao

    2015-11-01

    A Bradbury-Nielsen gate (BNG) is often used to modulate ion beams. It consists of two interleaved and electrically isolated sets of wires with uniform tension, which ideally keep parallel, equidistant, and coplanar over a wide temperature range, making the BNG reliable and robust. We have previously analyzed the non-uniformity problem of wire tensions with sequentially winding method and developed a template-based transfer method to solve this problem. In this paper, we introduced a progressively reduced pretension method, which allows directly and sequentially fixing wires onto the substrate without using a template. Theoretical analysis shows that by applying proper pretension to each wire when fixing it, the final wire tensions of all wires can be uniform. The algorithm and flowchart to calculate the pretension sequence are given, and the fabrication process is introduced in detail. Pretensions are generated by weight combination with a weaving device. A BNG with stainless steel wire and a printed circuit board substrate is constructed with this method. The non-uniformity of the final wire tensions is less than 2.5% in theory. The BNG is successfully employed in our ion mobility spectrometer, and the measured resolution is 33.5 at a gate opening time of 350 μs. Compared to the template-based method, this method is simpler, faster, and more flexible with comparable production quality when manufacturing BNGs with different configurations.

  13. A progressively reduced pretension method to fabricate Bradbury-Nielsen gates with uniform tension

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Kai, E-mail: ni.kai@sz.tsinghua.edu.cn; Guo, Jingran; Yu, Zhou; Cao, Like; Yu, Quan; Qian, Xiang [Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China); Wang, Xiaohao [Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China); State Key Laboratory of Precision Measure Technology and Instruments, Tsinghua University, Beijing 100084 (China)

    2015-11-15

    A Bradbury-Nielsen gate (BNG) is often used to modulate ion beams. It consists of two interleaved and electrically isolated sets of wires with uniform tension, which ideally keep parallel, equidistant, and coplanar over a wide temperature range, making the BNG reliable and robust. We have previously analyzed the non-uniformity problem of wire tensions with sequentially winding method and developed a template-based transfer method to solve this problem. In this paper, we introduced a progressively reduced pretension method, which allows directly and sequentially fixing wires onto the substrate without using a template. Theoretical analysis shows that by applying proper pretension to each wire when fixing it, the final wire tensions of all wires can be uniform. The algorithm and flowchart to calculate the pretension sequence are given, and the fabrication process is introduced in detail. Pretensions are generated by weight combination with a weaving device. A BNG with stainless steel wire and a printed circuit board substrate is constructed with this method. The non-uniformity of the final wire tensions is less than 2.5% in theory. The BNG is successfully employed in our ion mobility spectrometer, and the measured resolution is 33.5 at a gate opening time of 350 μs. Compared to the template-based method, this method is simpler, faster, and more flexible with comparable production quality when manufacturing BNGs with different configurations.

  14. Lignification and tension wood.

    Science.gov (United States)

    Pilate, Gilles; Chabbert, Brigitte; Cathala, Bernard; Yoshinaga, Arata; Leplé, Jean-Charles; Laurans, Françoise; Lapierre, Catherine; Ruel, Katia

    2004-01-01

    Hardwood trees are able to reorient their axes owing to tension wood differentiation. Tension wood is characterised by important ultrastructural modifications, such as the occurrence in a number of species, of an extra secondary wall layer, named gelatinous layer or G-layer, mainly constituted of cellulose microfibrils oriented nearly parallel to the fibre axis. This G-layer appears directly involved in the definition of tension wood mechanical properties. This review gathers the data available in the literature about lignification during tension wood formation. Potential roles for lignin in tension wood formation are inferred from biochemical, anatomical and mechanical studies, from the hypotheses proposed to describe tension wood function and from data coming from new research areas such as functional genomics.

  15. Rotor Embedded with Shape Memory Alloy Wires

    Directory of Open Access Journals (Sweden)

    K. Gupta

    2000-01-01

    Full Text Available In the present analysis, the fundamental natural frequency of a Jeffcott and a two-mass rotor with fibre reinforced composite shaft embedded with shape memory alloy (SMA wires is evaluated by Rayleigh's procedure. The flexibility of rotor supports is taken into account. The effect of three factors, either singly or in combination with each other, on rotor critical speed is studied. The three factors are: (i increase in Young's modulus of SMA (NITINOL wires when activated, (ii tension in wires because of phase recovery stresses, and (iii variation of support stiffness by three times because of activation of SMA in rotor supports. It is shown by numerical examples that substantial variation in rotor critical speeds can be achieved by a combination of these factors which can be effectively used to avoid resonance during rotor coast up/down.

  16. Construction and Assembly of the Wire Planes for the MicroBooNE Time Projection Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Acciarri, R. [Fermilab; Adams, C. [Yale U.; Asaadi, J. [Texas A-M; Danaher, J. [Fermilab; Fleming, B. T. [Yale U.; Gardner, R. [Fermilab; Gollapinni, S. [Kansas State U.; Grosso, R. [Cincinnati U.; Guenette, R. [Oxford U.; Littlejohn, B. R. [IIT, Chicago; Lockwitz, S. [Fermilab; Raaf, J. L. [Fermilab; Soderberg, M. [Syracuse U.; St. John, J. [Cincinnati U.; Strauss, T. [Fermilab; Szelc, A. M. [Manchester U.; Yu, B. [Brookhaven

    2017-03-09

    In this paper we describe how the readout planes for the MicroBooNE Time Projection Chamber were constructed, assembled and installed. We present the individual wire preparation using semi-automatic winding machines and the assembly of wire carrier boards. The details of the wire installation on the detector frame and the tensioning of the wires are given. A strict quality assurance plan ensured the integrity of the readout planes. The different tests performed at all stages of construction and installation provided crucial information to achieve the successful realization of the MicroBooNE wire planes.

  17. Construction and Assembly of the Wire Planes for the MicroBooNE Time Projection Chamber

    CERN Document Server

    Acciarri, R; Asaadi, J; Danaher, J; Fleming, B T; Gardner, R; Gollapinni, S; Grosso, R; Guenette, R; Littlejohn, B R; Lockwitz, S; Raaf, J L; Soderberg, M; John, J St; Strauss, T; Szelc, A M; Yu, B

    2016-01-01

    In this paper we describe how the readout planes for the MicroBooNE Time Projection Chamber were constructed, assembled and installed. We present the individual wire preparation using semi-automatic winding machines and the assembly of wire carrier boards. The details of the wire installation on the detector frame and the tensioning of the wires are given. A strict quality assurance plan ensured the integrity of the readout planes. The different tests performed at all stages of construction and installation provided crucial information to achieve the successful realisation of the MicroBooNE wire planes.

  18. The biomechanical evaluation of polyester as a tension band for the internal fixation of patellar fractures.

    LENUS (Irish Health Repository)

    McGreal, G

    2012-02-03

    We use a braided polyester suture in place of cerclage wire in tension band fixations. The objective of this study was to test the biomechanical properties of this technique. Sixteen cadaveric patellae were fractured and repaired by modified tension band fixation. Eight were fixed using eighteen gauge stainless steel wire as a tension band and eight using braided polyester. All specimens were subjected to tensile testing. Polyester was 75.0% as strong as wire. For dynamic testing, the patellae of seven cadaveric knees were fractured and then fixed with polyester tension bands. These were mounted in a device capable of extending the knees from 90 degrees to neutral against an applied force. None of the fixations failed. Three of the specimens fixed using 18 gauge stainless steel wire were compared with three fixed using polyester over 2000 cycles of knee flexion and extension. Polyester performed as well as wire. We conclude that polyester is an acceptable alternative to wire in tension band fixation.

  19. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  20. Wire harness twisting aid

    Science.gov (United States)

    Casey, E. J.; Commadore, C. C.; Ingles, M. E.

    1980-01-01

    Long wire bundles twist into uniform spiral harnesses with help of simple apparatus. Wires pass through spacers and through hand-held tool with hole for each wire. Ends are attached to low speed bench motor. As motor turns, operator moves hand tool away forming smooth twists in wires between motor and tool. Technique produces harnesses that generate less radio-frequency interference than do irregularly twisted cables.

  1. Pull-pull position control of dual motor wire rope transmission

    Science.gov (United States)

    Guo, Quan; Jiao, Zongxia; Yan, Liang; Yu, Qian; Shang, Yaoxing

    2016-08-01

    Wire rope transmission is very efficient because of the small total moving object mass. The wire rope could only transmit pulling force. Therefore it has to be kept in a tightened state during transmission; in high speed applications the dynamic performance depends on the rope's stiffness, which can be adjusted by the wire rope tension. To improve the system dynamic performance output, this paper proposes a novel pull-pull method based on dual motors connected by wire ropes, for precise, high speed position control applications. The method can regulate target position and wire rope tension simultaneously. Wire ropes remain in a pre-tightening state at all times, which prevents the influence of elasticity and reduces the position tracking error in the changing direction process. Simulations and experiments were conducted; the results indicate that both position precision and superior dynamic performance can be synchronously achieved. The research is relevant to space craft precision pointing instruments.

  2. Development of Rotary Axis For Wire Electrical Discharge Machining (WEDM

    Directory of Open Access Journals (Sweden)

    M. Parthiban, C. Manigandan, G. Muthu Venkadesh, M. Ranjith Kumar

    2013-08-01

    Full Text Available This paper gives an overview of setting up a rotary axis to the existing WEDM machine to investigate the machining parameters in WEDG of harder materials. There are a number of hybrid machining processes (HMPs seeking the combined advantage of EDM and other machining techniques. One such combination is wire electrical discharge grinding (WEDG, which is commonly used for micro-machining of fine and hard rods. WEDG employs a single wire guide to confine the wire tension within the discharge area between the rod and the front edge of the wire and also to minimize the wire vibration. Other advantages of WEDG include the ability to machine hard- to- machine materials with large aspect ratio.

  3. Water Desalination with Wires

    NARCIS (Netherlands)

    Porada, S.; Sales, B.B.; Hamelers, H.V.M.; Biesheuvel, P.M.

    2012-01-01

    We show the significant potential of water desalination using a novel capacitive wire-based technology in which anode/cathode wire pairs are constructed from coating a thin porous carbon electrode layer on top of electrically conducting rods (or wires). By alternately dipping an array of electrode

  4. Design and control of a Nitinol wire actuated rotary servo

    Science.gov (United States)

    Song, G.

    2007-10-01

    This paper presents the design and control of a rotary servo actuated by a shape memory alloy (SMA) wire. A new rotary servo device using Nitinol type of SMA wire is designed and fabricated in this study. This new rotary actuator utilizes a Nitinol wire wound on a threaded non-conductive rotor. One end of the Nitinol wire is fixed to the rotor and the other end is fixed to the supporting base plate. The rotor is connected to a pre-tensioned torsional spring such that two-way rotation can be achieved. Upon heating of the Nitinol wire using electric current, the wire contracts, causing the rotor to rotate, since the other end of the SMA wire is rigidly connected to the base plate. This rotor design is compact and offers a space-saving solution for the use of SMA wire actuators. To actively control the servo, a sliding-mode based robust control approach is used. The sliding-mode based robust control consists of three components: a standard proportional plus derivative (PD) control term, a feedforward term used as a bias current, and a robust term to increase system stability and concurrently control accuracy. Experimental results confirm the functionality of the Nitinol wire actuated rotary servo and show this device can be precisely controlled using the sliding-mode based robust control approach.

  5. Effect of wire shape on wire array discharge

    Energy Technology Data Exchange (ETDEWEB)

    Shimomura, N.; Tanaka, Y.; Yushita, Y.; Nagata, M. [University of Tokushima, Department of Electrical and Electronic Engineering, Tokushima (Japan); Teramoto, Y.; Katsuki, S.; Akiyama, H. [Kumamoto University, Department of Electrical and Computer Engineering, Kumamoto (Japan)

    2001-09-01

    Although considerable investigations have been reported on z-pinches to achieve nuclear fusion, little attention has been given from the point of view of how a wire array consisting of many parallel wires explodes. Instability existing in the wire array discharge has been shown. In this paper, the effect of wire shape in the wire array on unstable behavior of the wire array discharge is represented by numerical analysis. The claws on the wire formed in installation of wire may cause uniform current distribution on wire array. The effect of error of wire diameter in production is computed by Monte Carlo Method. (author)

  6. PS wire chamber

    CERN Multimedia

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  7. Tension chylothorax following pneumonectomy

    Directory of Open Access Journals (Sweden)

    Hemang Yadav

    2015-01-01

    Full Text Available Post-pneumonectomy chylothorax is an uncommon complication following surgery, with an estimated incidence of less than 0.7%. Post-pneumonectomy tension chylothorax, where rapid accumulation of chyle in the post-pneumonectomy space results in hemodynamic compromise, is exceedingly rare, with just 7 cases previously reported. All prior cases of tension chylothorax were managed operatively with decompressive chest tube placement followed by open thoracic duct repair. Our case is the first reported tension chylothorax to be managed conservatively by thoracostomy drainage coupled with a period of parenteral nutrition followed by a medium chain triglyceride-restricted diet.

  8. The design and testing of a wire velocimeter.

    Science.gov (United States)

    Witters, J; Heremans, G; Bohets, W; Stijnen, V; Van Coppenolle, H

    1985-01-01

    The basic principles underlying the design of a velocimeter based on an unwinding wire, for use in athletics research, are discussed. It is shown by theoretical analysis that, in order to avoid runaway effects, the tension on the wire should be either high or low but not of intermediate strength. The low tension regime is shown to be theoretically the most favourable as it combines high accuracy of speed measurements in decelerated motion with insensitivity to resonance oscillations of the wire. Practical considerations concerning the ruggedness of the apparatus, however, favour the high tension regime. A modern apparatus incorporating microprocessors and working with thin nylon wire stretched by a force of the order of 1 N, i.e. in the high tension regime, has been constructed and tested. The test results show that the velocity of decelerated motions (up to decelerations of the order of 10 m s-2) can be faithfully recorded in the velocity range 0-15 m s-1. The relative error for the measurement of constant speed up to 15 m s-1 is about one in a thousand, which is very small and practically unattainable by other methods. An application to the study of the long jump is demonstrated and validated by the use of film analysis.

  9. Tuning a Tetrahertz Wire Laser

    Science.gov (United States)

    Qin, Qi; Williams, Benjamin S.; Kumar, Sushil; Reno, John L.; Hu, Qing

    2009-01-01

    Tunable terahertz lasers are desirable in applications in sensing and spectroscopy because many biochemical species have strong spectral fingerprints at terahertz frequencies. Conventionally, the frequency of a laser is tuned in a similar manner to a stringed musical instrument, in which pitch is varied by changing the length of the string (the longitudinal component of the wave vector) and/ or its tension (the refractive index). However, such methods are difficult to implement in terahertz semiconductor lasers because of their poor outcoupling efficiencies. Here, we demonstrate a novel tuning mechanism based on a unique 'wire laser' device for which the transverse dimension w is much much less than lambda. Placing a movable object close to the wire laser manipulates a large fraction of the waveguided mode propagating outside the cavity, thereby tuning its resonant frequency. Continuous single-mode redshift and blueshift tuning is demonstrated for the same device by using either a dielectric or metallic movable object. In combination, this enables a frequency tuning of approximately equal to 137 GHz (3.6%) from a single laser device at approximately equal to 3.8 THz.

  10. Optic nerve oxygen tension

    DEFF Research Database (Denmark)

    la Cour, M; Kiilgaard, Jens Folke; Eysteinsson, T

    2000-01-01

    To investigate the influence of acute changes in intraocular pressure on the oxygen tension in the vicinity of the optic nerve head under control conditions and after intravenous administration of 500 mg of the carbonic anhydrase inhibitor dorzolamide....

  11. Thermally Insulating, Kinematic Tensioned-Fiber Suspension

    Science.gov (United States)

    Voellmer, George M.

    2004-01-01

    A salt pill and some parts of a thermally insulating, kinematic suspension system that holds the salt pill rigidly in an adiabatic-demagnetization refrigerator (ADR) is presented. "Salt pill" in this context denotes a unit comprising a cylindrical container, a matrix of gold wires in the container, and a cylinder of ferric ammonium alum (a paramagnetic salt) that has been deposited on the wires. The structural members used in this system for both thermal insulation and positioning are aromatic polyamide fibers (Kevlar(R) or equivalent) under tension. This suspension system is designed to satisfy several special requirements to ensure the proper operation of the ADR. These requirements are to (1) maintain the salt pill at a specified position within the cylindrical bore of an electromagnet; (2) prevent vibrations, which would cause dissipation of heat in the salt pill; and (3) minimize the conduction of heat from the electromagnet bore and other neighboring objects to the salt pill; all while (4) protecting the salt pill (which is fragile) against all tensile and bending loads other than those attributable to its own weight. In addition, the system is required to consist of two subsystems -- one for the top end and one for the bottom end of the salt pill -- that can be assembled and tensioned separately from each other and from the salt pill, then later attached to the salt pill.

  12. Uniaxial tension of drying sieves

    Directory of Open Access Journals (Sweden)

    Bojić Nada V.

    2013-01-01

    Full Text Available Although the literature contains numerous studies that have been developed to describe the nonlinear behavior of drying sieves' operation, there are no papers in this which report deeper investigation of the drying sieve behavior when exposed to tension and thermo stabilization. The aim of this paper is to provide insight into the elastoplastic behavior of the thermo stabilized and not stabilized sieves subjected to the tensile force. Within this work both theoretical and experimental investigations were performed. The sieves were joined by using a spiral. In separate experiments tests of wire base and weft of the weave mesh were performed, both for thermo stabilized and not thermo stabilized sieves, sieves joining and the sieve thermo stabilization itself. It was established that the thermo stabilization of sieves provides for stability of sieves' dimensions and that open thermo stabilized drying sieve exhibits better mechanical properties and exploitation characteristics then the sieves joining. [Projekat Ministarstva nauke Republike Srbije, br. ON174004: Micromechanics criteria of damage and fracture and br. TR 32036: Development of software for solving the coupled multi-physical problems

  13. Reversible dilatancy in entangled single-wire materials.

    Science.gov (United States)

    Rodney, David; Gadot, Benjamin; Martinez, Oriol Riu; du Roscoat, Sabine Rolland; Orgéas, Laurent

    2016-01-01

    Designing structures that dilate rapidly in both tension and compression would benefit devices such as smart filters, actuators or fasteners. This property however requires an unusual Poisson ratio, or Poisson function at finite strains, which has to vary with applied strain and exceed the familiar bounds: less than 0 in tension and above 1/2 in compression. Here, by combining mechanical tests and discrete element simulations, we show that a simple three-dimensional architected material, made of a self-entangled single long coiled wire, behaves in between discrete and continuum media, with a large and reversible dilatancy in both tension and compression. This unusual behaviour arises from an interplay between the elongation of the coiled wire and rearrangements due to steric effects, which, unlike in traditional discrete media, are hysteretically reversible when the architecture is made of an elastic fibre.

  14. 30 CFR 77.1802 - Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley...

    Science.gov (United States)

    2010-07-01

    ... wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 77.1802 Section 77.1802... Wires and Trolley Feeder Wires § 77.1802 Insulation of trolley wires, trolley feeder wires and bare..., and bare signal wires shall be adequately guarded: (a) At all points where men are required to work or...

  15. Vibrating wire alignment technique

    CERN Document Server

    Xiao-Long, Wang; lei, Wu; Chun-Hua, Li

    2013-01-01

    Vibrating wire alignment technique is a kind of method which through measuring the spatial distribution of magnetic field to do the alignment and it can achieve very high alignment accuracy. Vibrating wire alignment technique can be applied for magnet fiducialization and accelerator straight section components alignment, it is a necessary supplement for conventional alignment method. This article will systematically expound the international research achievements of vibrating wire alignment technique, including vibrating wire model analysis, system frequency calculation, wire sag calculation and the relation between wire amplitude and magnetic induction intensity. On the basis of model analysis this article will introduce the alignment method which based on magnetic field measurement and the alignment method which based on amplitude and phase measurement. Finally, some basic questions will be discussed and the solutions will be given.

  16. Wire + Arc Additive Manufacturing

    OpenAIRE

    Williams, Stewart W.; Martina, Filomeno; Addison, Adrian C.; Ding, Jialuo; Pardal, Goncalo; Colegrove, Paul A.

    2016-01-01

    Depositing large components (>10 kg) in titanium, aluminium, steel and other metals is possible using Wire + Arc Additive Manufacturing. This technology adopts arc welding tools and wire as feedstock for additive manufacturing purposes. High deposition rates, low material and equipment costs, and good structural integrity make Wire+Arc Additive Manufacturing a suitable candidate for replacing the current method of manufacturing from solid billets or large forgings, especially with regards to ...

  17. Charpak hemispherical wire chamber

    CERN Multimedia

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  18. Photovoltaic Wire Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  19. On-Wire Lithography

    National Research Council Canada - National Science Library

    Lidong Qin; Sungho Park; Ling Huang; Chad A. Mirkin

    2005-01-01

    .... This procedure, termed on-wire lithography, combines advances in template-directed synthesis of nanowires with electrochemical deposition and wet-chemical etching and allows routine fabrication...

  20. 1998 wire development workshop proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development.

  1. Repair of olecranon fractures using fiberWire without metallic implants: report of two cases

    Directory of Open Access Journals (Sweden)

    Okawa Atsushi

    2010-10-01

    Full Text Available Abstract Olecranon fractures are a common injury in fractures. The tension band technique for olecranon fractures yields good clinical outcomes; however, it is associated with significant complications. In many patients, implants irritate overlying soft tissues and cause pain. This is mostly due to protrusion of the proximal ends of the K-wires or by the twisted knots of the metal wire tension band. Below we described 2 cases of olecranon fractures treated with a unique technique using FiberWire without any metallic implants. Technically, the fragment was reduced, and two K-wires were inserted from the dorsal cortex of the distal segment to the tip of the olecranon. K-wire was exchanged for a suture retriever, and 2 strands of FiberWire were retrieved twice. Each of the two FiberWires was manually tensioned and knotted on the posterior surface of the olecranon. Bony unions could be achieved, and patients had no complaint of pain and skin irritation. There was only a small loss of flexion and extension in comparison with that of the contralateral side, and the patient did not feel inconvenienced in his daily life. Using the method described, difficulty due to K-wire or other metallic implants was avoided.

  2. Repair of olecranon fractures using fiberWire without metallic implants: report of two cases

    Science.gov (United States)

    2010-01-01

    Olecranon fractures are a common injury in fractures. The tension band technique for olecranon fractures yields good clinical outcomes; however, it is associated with significant complications. In many patients, implants irritate overlying soft tissues and cause pain. This is mostly due to protrusion of the proximal ends of the K-wires or by the twisted knots of the metal wire tension band. Below we described 2 cases of olecranon fractures treated with a unique technique using FiberWire without any metallic implants. Technically, the fragment was reduced, and two K-wires were inserted from the dorsal cortex of the distal segment to the tip of the olecranon. K-wire was exchanged for a suture retriever, and 2 strands of FiberWire were retrieved twice. Each of the two FiberWires was manually tensioned and knotted on the posterior surface of the olecranon. Bony unions could be achieved, and patients had no complaint of pain and skin irritation. There was only a small loss of flexion and extension in comparison with that of the contralateral side, and the patient did not feel inconvenienced in his daily life. Using the method described, difficulty due to K-wire or other metallic implants was avoided. PMID:20937160

  3. Blood Vessel Tension Tester

    Science.gov (United States)

    1978-01-01

    In the photo, a medical researcher is using a specially designed laboratory apparatus for measuring blood vessel tension. It was designed by Langley Research Center as a service to researchers of Norfolk General Hospital and Eastern Virginia Medical School, Norfolk, Virginia. The investigators are studying how vascular smooth muscle-muscle in the walls of blood vessels-reacts to various stimulants, such as coffee, tea, alcohol or drugs. They sought help from Langley Research Center in devising a method of measuring the tension in blood vessel segments subjected to various stimuli. The task was complicated by the extremely small size of the specimens to be tested, blood vessel "loops" resembling small rubber bands, some only half a millimeter in diameter. Langley's Instrumentation Development Section responded with a miniaturized system whose key components are a "micropositioner" for stretching a length of blood vessel and a strain gage for measuring the smooth muscle tension developed. The micropositioner is a two-pronged holder. The loop of Mood vessel is hooked over the prongs and it is stretched by increasing the distance between the prongs in minute increments, fractions of a millimeter. At each increase, the tension developed is carefully measured. In some experiments, the holder and specimen are lowered into the test tubes shown, which contain a saline solution simulating body fluid; the effect of the compound on developed tension is then measured. The device has functioned well and the investigators say it has saved several months research time.

  4. Miniaturized Linear Wire Ion Trap Mass Analyzer.

    Science.gov (United States)

    Wu, Qinghao; Li, Ailin; Tian, Yuan; Zare, Richard N; Austin, Daniel E

    2016-08-02

    We report a linear ion trap (LIT) in which the electric field is formed by fine wires held under tension and accurately positioned using holes drilled in two end plates made of plastic. The coordinates of the hole positions were optimized in simulation. The stability diagram and mass spectra using boundary ejection were compared between simulation and experiment and good agreement was found. The mass spectra from experiments show peak widths (fwhm) in units of mass-to-charge of around 0.38 Th using a scan rate of 3830 Th/s. The limits of detection are 137 ppbv and 401 ppbv for benzene and toluene, respectively. Different sizes of the wire ion trap can be easily fabricated by drilling holes in scaled positions. Other distinguishing features, such as high ion and photon transmission, low capacitance, high tolerance to mechanical and assembly error, and low weight, are discussed.

  5. Wire Array Photovoltaics

    Science.gov (United States)

    Turner-Evans, Dan

    Over the past five years, the cost of solar panels has dropped drastically and, in concert, the number of installed modules has risen exponentially. However, solar electricity is still more than twice as expensive as electricity from a natural gas plant. Fortunately, wire array solar cells have emerged as a promising technology for further lowering the cost of solar. Si wire array solar cells are formed with a unique, low cost growth method and use 100 times less material than conventional Si cells. The wires can be embedded in a transparent, flexible polymer to create a free-standing array that can be rolled up for easy installation in a variety of form factors. Furthermore, by incorporating multijunctions into the wire morphology, higher efficiencies can be achieved while taking advantage of the unique defect relaxation pathways afforded by the 3D wire geometry. The work in this thesis shepherded Si wires from undoped arrays to flexible, functional large area devices and laid the groundwork for multijunction wire array cells. Fabrication techniques were developed to turn intrinsic Si wires into full p-n junctions and the wires were passivated with a-Si:H and a-SiNx:H. Single wire devices yielded open circuit voltages of 600 mV and efficiencies of 9%. The arrays were then embedded in a polymer and contacted with a transparent, flexible, Ni nanoparticle and Ag nanowire top contact. The contact connected >99% of the wires in parallel and yielded flexible, substrate free solar cells featuring hundreds of thousands of wires. Building on the success of the Si wire arrays, GaP was epitaxially grown on the material to create heterostructures for photoelectrochemistry. These cells were limited by low absorption in the GaP due to its indirect bandgap, and poor current collection due to a diffusion length of only 80 nm. However, GaAsP on SiGe offers a superior combination of materials, and wire architectures based on these semiconductors were investigated for multijunction

  6. Characterization of a mid-sized Li foil multi-wire proportional counter neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Kyle A., E-mail: knelson1@ksu.edu [S.M.A.R.T. Laboratory, Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States); Kusner, Michael R. [Saint-Gobain Crystals, Hiram, OH 44234 (United States); Montag, Benjamin W. [S.M.A.R.T. Laboratory, Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States); Mayhugh, Michael R. [Saint-Gobain Crystals, Hiram, OH 44234 (United States); Schmidt, Aaron J.; Wayant, Clayton D.; Shultis, J. Kenneth; Ugorowski, Philip B.; McGregor, Douglas S. [S.M.A.R.T. Laboratory, Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States)

    2014-10-21

    A 550 cm{sup 2} thermal neutron detector was constructed with five parallel sheets of 75 µm thick {sup 6}Li foil (95% enrichment) spaced 1.63 cm apart. Anode wire banks containing a plurality of anode wires were strung on both sides of each foil, six banks in total. The chamber was backfilled with P-10 proportional gas and over-pressured to 1.1, 1.5, 2.0, and 2.8 atm (111, 151, 202, and 284 kPa). The design was tailored to allow the products from the {sup 6}Li(n,t){sup 4}He reaction to escape both sides of the Li foil simultaneously, thereby, allowing for concurrent measurement in the proportional gas. The measured intrinsic thermal neutron detection efficiency of the detector with normal incident thermal neutrons to the foil sheets was 53.8±0.20%. When the detector was angled (55° from normal) such that a 0.5 cm diameter thermal neutron beam intersected all of the foil layers, the intrinsic thermal neutron detection efficiency increased to 58.6±0.21%. A {sup 252}Cf neutron source positioned at a distance of 2.0 m yielded an absolute neutron detection efficiency of 0.73 cps ng{sup −1}. The gamma-ray rejection ratio (GRR) was 7.67×10{sup –9} as measured from a {sup 60}Co source for an exposure rate of 40 mR hr{sup −1}. Theoretical pulse-height spectra obtained with MCNP6 agreed well with experimental data and allowed pulse-height spectra and discriminator settings to be energy-calibrated. These results demonstrate the potential for the Li foil multi-wire proportional counter (MWPC) as a viable {sup 3}He neutron detector replacement.

  7. Surface Tension of Spacetime

    Science.gov (United States)

    Perko, Howard

    2017-01-01

    Concepts from physical chemistry and more specifically surface tension are introduced to spacetime. Lagrangian equations of motion for membranes of curved spacetime manifold are derived. The equations of motion in spatial directions are dispersion equations and can be rearranged to Schrodinger's equation where Plank's constant is related to membrane elastic modulus. The equation of motion in the time-direction has two immediately recognizable solutions: electromagnetic waves and corpuscles. The corpuscular membrane solution can assume different genus depending on quantized amounts of surface energy. A metric tensor that relates empty flat spacetime to energetic curved spacetime is found that satisfies general relativity. Application of the surface tension to quantum electrodynamics and implications for quantum chromodynamics are discussed. Although much work remains, it is suggested that spacetime surface tension may provide a classical explanation that combines general relativity with field theories in quantum mechanics and atomic particle physics.

  8. The behavior of concrete cylinders confined by shape memory alloy wires

    Science.gov (United States)

    Choi, Eunsoo; Nam, Tae-hyun; Cho, Sung-Chul; Chung, Young-Soo; Park, Taehyo

    2008-12-01

    The purpose of this study was to propose a new method to confine concrete cylinders or reinforced concrete columns using martensitic or austenitic shape memory alloy (SMA) wires. The prestrained martensitic SMA wire was wrapped around a concrete cylinder then heated by a heating jacket. In the process, the confining stress around the cylinder was developed in the SMA wire due to the shape memory effect, which can increase the strength and ductility of the cylinder under axial compressive load. For austenitic shape memory wires, the wires were prestrained as they were wrapped around the concrete cylinders on which post-tensioning stress was generated. In this study, martensitic and austenitic SMA wires of 1.0 mm in diameter were used for the confinement. Recovery tests were conducted on the martensitic wire to assess the recovery stress. Also, a superelastic behavior test was performed for the austenitic wire. The confinement by martensitic SMA wires increased the strength slightly and greatly increased the ductility compared to the strength and ductility of plain concrete cylinders. The austenitic SMA wires showed a similar effect on concrete cylinders to that of the martensitic wires. This study showed the potential of the SMA wire jacketing method to retrofit reinforced concrete columns and protect them from seismic risks.

  9. The Tension Literature.

    Science.gov (United States)

    Frederick, A. B.

    This is a bibliography of literature on the subject of tension. Books, films, and periodicals with a bearing on stress, relaxation, anxiety, and/or methods of controlling stress are listed from the fields of physiology, psychology, and philosophy. New methods such as transcendental meditation and biofeedback are analyzed briefly and criteria are…

  10. Rein tension during canter

    NARCIS (Netherlands)

    Egenvall, Agneta; Eisersiö, Marie; Rhodin, Marie; van Weeren, P.R.; Roepstorff, Lars

    2015-01-01

    Riders generally use reins as a means for communication with the horse. At present, the signalling pattern is poorly understood. The aim of this study was to illustrate and analyse the rein tension patterns in a number of rider/horse combinations across a variety of exercises in the canter gait. Our

  11. Optic nerve oxygen tension

    DEFF Research Database (Denmark)

    Kiilgaard, Jens Folke; Pedersen, D B; Eysteinsson, T

    2004-01-01

    The authors have previously reported that carbonic anhydrase inhibitors such as acetazolamide and dorzolamide raise optic nerve oxygen tension (ONPO(2)) in pigs. The purpose of the present study was to investigate whether timolol, which belongs to another group of glaucoma drugs called beta...

  12. Optic nerve oxygen tension

    DEFF Research Database (Denmark)

    Kiilgaard, Jens Folke; Pedersen, D B; Eysteinsson, T

    2004-01-01

    The authors have previously reported that carbonic anhydrase inhibitors such as acetazolamide and dorzolamide raise optic nerve oxygen tension (ONPO(2)) in pigs. The purpose of the present study was to investigate whether timolol, which belongs to another group of glaucoma drugs called beta block...

  13. STRUCTURAL AND TECHNOLOGICAL ASPECTS OF DECREASE IN WIRE ANNEALING AT A TWIST OF A HIGH-STRENGTH METAL CORD

    Directory of Open Access Journals (Sweden)

    V. Р. Fetisov

    2016-01-01

    Full Text Available Deformation by drawing with the raised share of the squeezing tension and application of additional deformation with small degrees in the line of a drawing camp allow to minimize a wire annealing of a cold-deformed wire during a twist of a highstrength metal cord.

  14. Coulomb string tension, asymptotic string tension, and the gluon chain

    Science.gov (United States)

    Greensite, Jeff; Szczepaniak, Adam P.

    2015-02-01

    We compute, via numerical simulations, the nonperturbative Coulomb potential of pure SU(3) gauge theory in Coulomb gauge. We find that the Coulomb potential scales nicely in accordance with asymptotic freedom, that the Coulomb potential is linear in the infrared, and that the Coulomb string tension is about four times larger than the asymptotic string tension. We explain how it is possible that the asymptotic string tension can be lower than the Coulomb string tension by a factor of four.

  15. Considerations for fault current testing of optical ground wire

    Energy Technology Data Exchange (ETDEWEB)

    Madge, R.C.; Barrett, J.S.; Maruice, C.G. (Ontario Hydro, Toronto, ON (Canada). Research Div.)

    1992-10-01

    Optical Ground Wires (OPGW) are being used more frequently by utilities. However, fault current testing of OPGW has not been fully examined. In this paper, peak component temperatures are measured for both 10 m and 60 m spans. The cable temperature decay time is measured, and is compared against a numerical model of convection and conduction losses. A numerical model is developed to predict the peak cable tension following a hit. This model can be used to establish appropriate initial cable tensions to simulate full-span faults. The issue of dynamic stresses in the form of cable whipping is reviewed. Lastly, various cable termination procedures are tested.

  16. Cavitation during wire brushing

    Science.gov (United States)

    Li, Bo; Zou, Jun; Ji, Chen

    2016-11-01

    In our daily life, brush is often used to scrub the surface of objects, for example, teeth, pots, shoes, pool, etc. And cleaning rust and stripping paint are accomplished using wire brush. Wire brushes also can be used to clean the teeth for large animals, such as horses, crocodiles. By observing brushing process in water, we capture the cavitation phenomenon on the track of moving brush wire. It shows that the cavitation also can affect the surface. In order to take clear and entire pictures of cavity, a simplified model of one stainless steel wire brushing a boss is adopted in our experiment. A transparent organic tank filled with deionized water is used as a view box. And a high speed video camera is used to record the sequences. In experiment, ambient pressure is atmospheric pressure and deionized water temperature is kept at home temperature. An obvious beautiful flabellate cavity zone appears behind the moving steel wire. The fluctuation of pressure near cavity is recorded by a hydrophone. More movies and pictures are used to show the behaviors of cavitation bubble following a restoring wire. Beautiful tracking cavitation bubble cluster is captured and recorded to show.

  17. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  18. Effect of tensile and torsion on GMI in amorphous wire

    Science.gov (United States)

    Blanco, J. M.; Zhukov, A.; Gonzalez, J.

    1999-05-01

    GMI effect, Δ Z/Z = [ Z( H) - Z( Hmax)]/ Z( Hmax) has been measured in (Fe 0.94Co 0.06) 72.5B 15Si 12.5 wire under tensile, σ ten, and torsional, σ tor, stresses. Generally Δ Z/Z( H) dependence has a non-monotonic shape with a maximum at certain axial magnetic field, Hm. Both tension and torsion modify Δ Z/Z( H) dependence. Application of tension results in an increase of Hm with σ ten. Torsional stress dependence of GMI effect has asymmetry with a maximum at torsion angle, φ, around + 12π/m in as-cast wire, when Δ Z/Z is around 250%. An increase of Δ Z/Zm up to 350% and change of Δ Z/Z(φ) dependence towards a nearly symmetric shape have been observed after Joule heating.

  19. Tension optimization of the conductor-and-support cable elements during stranding process

    Directory of Open Access Journals (Sweden)

    I.M. Chayun

    2016-12-01

    Full Text Available Steel lifting ropes, cables and other similar products are rod statically undeterminable prestressed structures. Preliminary deformations of their elements (wires are caused by their manufacturing technology. Wires suffer stretching, bending with torsion in a stage of elastoplastic deformation. In this work the mechanic-mathematical model of residual forces determination in the wires of polymetallic conductor-and-support cable is offered. Aim: The aim of the work is studying of the mechanical and mathematical model defining residual forces in the wires of conductor-and-support cable and also the optimization of parameters of a twist by the criterion of residual forces lack after production process finishing. Materials and methods: The method developed by the authors earlier to the study the strain-stressed state of twisted wire products off-loading from technological internal forces has been applied to assess the impact of the approximate value of the longitudinal stiffness of the product. In this paper, each wire is considered as an element of the product individually. This is necessary to investigate the impact of uneven wire tensions on defects of conductor-and-support cable (out-of-straight in a free state and stripping-down. Results: On the basis of the conducted deformation studies of conductor-and-support cable during off-loading process from twist tension of its elements the dependencies of residual forces on the level and interrelation of elements tension has been determined. The condition of ensuring of zero residual forces in the wires of conductor-and-support cable after production is formulated. It was found that calculated values of residual forces are almost identical when using of the approximate and exact values of longitudinal stiffness of conductor-and-support cable.

  20. Improved wire stiffness with modified connection bolts in Ilizarov external frames: a biomechanical study.

    Science.gov (United States)

    Gessmann, Jan; Jettkant, Birger; Königshausen, Matthias; Schildhauer, Thomas Armin; Seybold, Dominik

    2012-01-01

    Frame stability in Ilizarov external fixators is mainly dependent on the tension of the transosseous wires, which are clamped to the ring by connection bolts. It was the purpose of this biomechanical study to investigate the holding capacity of a modified bolt design featuring a ruffled wire-bolt interface (TrueLok™) and its influence on wire stiffness in comparison with that of classic bolts featuring a smooth, unruffled wire-bolt interface. Six different ring and bolt configurations were tested using a simplified model consisting of a single ring and wire. The holding capacity at two different tightening torques (10 and 14 Nm) of classic cannulated bolts (CB) and slotted bolts (SB) was determined on Ilizarov and Taylor Spatial Frame (TSF™) rings, whereas the modified TrueLok™ CBs and SBs were used with the TrueLok™ rings. The wire stiffness was calculated via a regression analysis of the load-displacement graphs. The modified TrueLok™ bolts demonstrated significantly better slippage resistance than the classic bolts in all configurations and wire stiffness was significantly higher in the TrueLok™ frame set-ups. After maximum loading, all of the wires showed plastic deformation, including constant wire deflection and dent marks at the clamped wire ends. In conclusion, the decrease in wire stiffness can be explained mainly as a result of wire slippage, but plastic deformation and material yielding also contribute. The relatively simple modification made by roughening the wire-bolt interface results in improved holding capacity and wire stiffness. A frame that contains these modified TrueLok™ bolts should provide improved mechanical stiffness.

  1. A simple template-based transfer method to fabricate Bradbury-Nielsen gates with uniform tension for ion mobility spectrometry

    Science.gov (United States)

    Kai, Ni; Jingran, Guo; Guangli, Ou; Yu, Lei; Quan, Yu; Xiang, Qian; Xiaohao, Wang

    2014-08-01

    A Bradbury-Nielsen gate (BNG) consists of two interleaved and electrically isolated sets of wires. It is usually used to gate or modulate ion beams. Uniformly tense wires can remain parallel, equidistant, and coplanar over a wide working temperature range, which is critical to reliable BNG performance. Hence, this study analyzes the non-uniform tension of wires wound using traditional sequential winding methods in which the elastic modulus of the metal wire is much larger than that of the insulation substrate. To address this problem, a simple and reliable template-based transfer method is developed. First, a template with large elastic modulus is used to fabricate a wire mesh with uniform tension. The mesh is then transferred to the substrate. Theoretically, this method reduces the non-uniformity of the tension in wires to less than 2%; therefore, it is used to construct a BNG with stainless steel wire, a stainless steel template, and a printed circuit board substrate. The BNG was installed in our homebuilt ion mobility spectrometer. To confirm that the performance of the BNG meets the requirements of portable ion mobility spectrometry, signal intensity and resolution (approximately 30) were experimentally determined.

  2. A simple template-based transfer method to fabricate Bradbury–Nielsen gates with uniform tension for ion mobility spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kai, Ni, E-mail: ni.kai@sz.tsinghua.edu.cn; Jingran, Guo; Guangli, Ou; Yu, Lei; Quan, Yu; Xiang, Qian; Xiaohao, Wang [Division of Advanced Manufacturing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China)

    2014-08-15

    A Bradbury–Nielsen gate (BNG) consists of two interleaved and electrically isolated sets of wires. It is usually used to gate or modulate ion beams. Uniformly tense wires can remain parallel, equidistant, and coplanar over a wide working temperature range, which is critical to reliable BNG performance. Hence, this study analyzes the non-uniform tension of wires wound using traditional sequential winding methods in which the elastic modulus of the metal wire is much larger than that of the insulation substrate. To address this problem, a simple and reliable template-based transfer method is developed. First, a template with large elastic modulus is used to fabricate a wire mesh with uniform tension. The mesh is then transferred to the substrate. Theoretically, this method reduces the non-uniformity of the tension in wires to less than 2%; therefore, it is used to construct a BNG with stainless steel wire, a stainless steel template, and a printed circuit board substrate. The BNG was installed in our homebuilt ion mobility spectrometer. To confirm that the performance of the BNG meets the requirements of portable ion mobility spectrometry, signal intensity and resolution (approximately 30) were experimentally determined.

  3. Distribution of wire deformation within strands of wire ropes

    Institute of Scientific and Technical Information of China (English)

    MA Jun; GE Shi-rong; ZHANG De-kun

    2008-01-01

    Using ANSYS software, we developed a modeling program for several kinds of wire ropes with metal cores and built a geometric model for the 6x19 IWS wire rope. Through proper grid partitioning, a finite element model for calculating the deformation of wire rope was obtained. Completely constraining one end of the wire rope and applying an axial force to the other end, we established the boundary conditions for solving the model. In addition, we numerically simulated the stress and deformation of the wire, obtaining the deformation distribution of each wire within the wire rope under different laying directions.At the end, a tensile test of the 6x19 IWS wire rope was carried out and the results of simulation and experiment compared.

  4. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  5. Wiring and lighting

    CERN Document Server

    Kitcher, Chris

    2013-01-01

    Wiring and Lighting provides a comprehensive guide to DIY wiring around the home. It sets out the regulations and legal requirements surrounding electrical installation work, giving clear guidelines that will enable the reader to understand what electrical work they are able to carry out, and what the testing and certification requirements are once the work is completed. Topics covered include: Different types of circuits; Types of cables and cable installation under floors and through joists; Isolating, earthing and bonding; Accessory boxes and fixings; Voltage bands; Detailed advice on safe

  6. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  7. Research of 1770 MPa galvanized steel wire for stay cable of domestic bridges

    Institute of Scientific and Technical Information of China (English)

    Ding Feng; Sang Chunming; Zhou Daiyi; Bai Bingdong

    2009-01-01

    This paper focuses on introducing the manufacture technology of 1 770 MPa galvanized steel wires for stay cables applied to domestic bridges. During the development practices of high strength galvanized wire for stay cables used in Sutong Bridge, Baosteel has established three key technologies based on research of manufacture technology and technical innovation. The three key technologies are: "Double Tensioning + limiter die" process, "dominant process + fine adjustment" in integrated optimization technology and "three-level control" in hot dip galvanization. With these key technologies, Baosteet has produced 1 770 MPa galvanized wires for stay cable, which has high tensile strength, low relaxation and good torsion performances.

  8. Fragmentation in Biaxial Tension

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, G H; Archbold, G C; Hurricane, O A; Miller, P L

    2006-06-13

    We have carried out an experiment that places a ductile stainless steel in a state of biaxial tension at a high rate of strain. The loading of the ductile metal spherical cap is performed by the detonation of a high explosive layer with a conforming geometry to expand the metal radially outwards. Simulations of the loading and expansion of the metal predict strain rates that compare well with experimental observations. A high percentage of the HE loaded material was recovered through a soft capture process and characterization of the recovered fragments provided high quality data, including uniform strain prior to failure and fragment size. These data were used with a modified fragmentation model to determine a fragmentation energy.

  9. Tension-filled Governance?

    DEFF Research Database (Denmark)

    Celik, Tim Holst

    Since the crisis-engrossed 1970s, and especially the 1990s, ‘governance’ has become a dominant concern and concept; notably, within particularly political science, a certain diagnosis explicitly or implicitly focused on a shift ‘from government to governance’ has become increasingly popular....... This study examines the governance phenomenon of the post-1970/1990s period from a state-situated and historically informed perspective. Specifically, taking initial analytical departure in an approach of the early 1970s associated with James O’Connor, Jürgen Habermas and Claus Offe focused...... on the statesituated tension-filled functional relationship between legitimation and accumulation, the study both historically and theoretically reworks this approach and reapplies it for the post-1970s/1990s governance period. It asks whether and to what extent governance has served as a distinctive post- 1970s/1990s...

  10. Social and environmental tensions

    DEFF Research Database (Denmark)

    Saito, Moeko; Rutt, Rebecca Leigh; Chhetri, Bir Bahadur Khanal

    2014-01-01

    them, receive payments not only to address inequities but also for resource conservation. Drawing on a case study of a NORAD pilot project in Nepal, this paper investigates how affirmative measures adopted under the project affect different social actors and their perceptions and behaviors in relation......REDD + is a mitigation measure against global climate change that offers payments to developing countries based on the increased volume of forest carbon. It has been argued that affirmative measures should be adopted to ensure that communities, particularly the socially disadvantaged groups among...... to forests. Our case highlights the risk that the mere application of affirmative measures may give rise to difficult social and environmental tensions. Thus, this paper calls for such measures to effectively incorporate local perspectives in their designs and to be reflective, by allowing for regular...

  11. Practical wiring in SI units

    CERN Document Server

    Miller, Henry A

    2013-01-01

    Practical Wiring, Volume 1 is a 13-chapter book that first describes some of the common hand tools used in connection with sheathed wiring. Subsequent chapters discuss the safety in wiring, cables, conductor terminations, insulating sheathed wiring, conductor sizes, and consumer's control equipments. Other chapters center on socket outlets, plugs, lighting subcircuits, lighting accessories, bells, and primary and secondary cells. This book will be very valuable to students involved in this field of interest.

  12. Research on Web Press Tension Control System

    OpenAIRE

    Chen Sheng Jiang; Zhang Chun Feng; Wang Zhong You; Li Qing Lin

    2016-01-01

    Tension control of press is a key and difficult point of the whole machine control. The stand or fall of tension is directly related to the quality of the products. According to the characteristics of the web press tension control, this paper expounds the main factors influencing tension and the purpose of tension control, researches on the tension control principle of web tape, analyzes control rule and control circuit of tension control system, illustrates the advantages of PID control law ...

  13. 3D Wire 2015

    DEFF Research Database (Denmark)

    Jordi, Moréton; F, Escribano; J. L., Farias

    This document is a general report on the implementation of gamification in 3D Wire 2015 event. As the second gamification experience in this event, we have delved deeply in the previous objectives (attracting public areas less frequented exhibition in previous years and enhance networking) and ha......, improves socialization and networking, improves media impact, improves fun factor and improves encouragement of the production team....

  14. One-wire thermocouple

    Science.gov (United States)

    Goodrich, W. D.; Staimach, C. J.

    1977-01-01

    Nickel alloy/constantan device accurately measures surface temperature at precise locations. Device is moderate in cost and simplifies fabrication of highly-instrumented seamless-surface heat-transfer models. Device also applies to metal surfaces if constantan wire has insulative coat.

  15. Fatigue life prediction method for contact wire using maximum local stress

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Seok; Haochuang, Li; Seok, Chang Sung; Koo, Jae Mean [Sungkyunkwan University, Suwon (Korea, Republic of); Lee, Ki Won; Kwon, Sam Young; Cho, Yong Hyeon [Korea Railroad Research Institute, Uiwang (Korea, Republic of)

    2015-01-15

    Railway contact wires supplying electricity to trains are exposed to repeated mechanical strain and stress caused by their own weight and discontinuous contact with a pantograph during train operation. Since the speed of railway transportation has increased continuously, railway industries have recently reported a number of contact wire failures caused by mechanical fatigue fractures instead of normal wear, which has been a more common failure mechanism. To secure the safety and durability of contact wires in environments with increased train speeds, a bending fatigue test on contact wire has been performed. The test equipment is too complicated to evaluate the fatigue characteristics of contact wire. Thus, the axial tension fatigue test was performed for a standard specimen, and the bending fatigue life for the contact wire structure was then predicted using the maximum local stress occurring at the top of the contact wire. Lastly, the tested bending fatigue life of the structure was compared with the fatigue life predicted by the axial tension fatigue test for verification.

  16. Research on Web Press Tension Control System

    Directory of Open Access Journals (Sweden)

    Chen Sheng Jiang

    2016-01-01

    Full Text Available Tension control of press is a key and difficult point of the whole machine control. The stand or fall of tension is directly related to the quality of the products. According to the characteristics of the web press tension control, this paper expounds the main factors influencing tension and the purpose of tension control, researches on the tension control principle of web tape, analyzes control rule and control circuit of tension control system, illustrates the advantages of PID control law adopted in the tension control system, and concludes the influencing factors of paper tape tension control system and the corresponding problems needed to solve in the control.

  17. Longwall AFC chain tension meter

    Energy Technology Data Exchange (ETDEWEB)

    Peter Lugg; Zhiqiang Guan; Bart Pienaar [CRC Mining (Australia)

    2008-02-15

    Evaluation of the downtime statistics of two longwall mines studied as part of the Landmark Automation Project showed that AFC (Armoured Face Conveyor) and BSL (Beam Stage Loader) chain related failures accounted for 27% of all downtime. A chain tension meter was designed, certified Ex ia for use in ERZ0 sections of Australian coal mines and successfully field trialled on a longwall face during production. The dynamic behaviour and unequal sharing of load between the chains were recorded and found to be significant. The changing format of tension distribution around the conveyor as it is loaded was recorded and the implications of the change in the location of the point of minimum tension from tailgate to maingate as the conveyor is unloaded emphasised. The trial was run monitoring AFC chain tensions over a few shifts. The project successfully demonstrated that the measurement of AFC chain tensions on a working face can be achieved reliably.

  18. Social Reproduction and Political Change in The Wire

    DEFF Research Database (Denmark)

    Jensen, Mikkel Bo Brendstrup

    2017-01-01

    This paper examines a core tension in the political television serial The Wire (2002-2008). While several critics have argued that this show is both “bleak” and “systemic” in its portrayal of contemporary society, this paper argues that it is useful to understand these textual elements as building...

  19. Curvature effect on the mechanical behaviour of a martensitic shape-memory-alloy wire for applications in civil engineering

    Science.gov (United States)

    Tran, Hanh; Balandraud, Xavier; Destrebecq, Jean-François

    2015-02-01

    The mechanical response of a bent shape memory alloy (SMA) wire is a key point for the understanding of the process of the creation of confining effects in a wrapped concrete cylinder for example. The objective of the present study is to model the phenomena involved in the bending of a martensitic SMA wire. The mechanism of martensite reorientation is considered in the model, which also takes into account the asymmetry between tension and compression. For validation purposes, experiments were performed on Ni-Ti wires: measurement of residual curvatures after bending release and tensile tests on pre-bent wires. In particular, the analysis shows a variation in axial stiffness as a function of the preliminary curvature. This result shows the necessity of modelling the distributions of the state variables within the wire cross-section for the simulation of confinement processes using SMA wires. It also opens prospects to potential application to the bending of SMA fibres in smart textiles.

  20. Mechanical and Corrosive Properties of Two Magnesium Wires: Mg4Gd and Mg6Ag

    Science.gov (United States)

    Maier, Petra; Szakács, Gabor; Wala, Marcin; Hort, Norbert

    The mechanical and corrosive properties of two Magnesium wires are studied in the field of microhardness, tension-, compression-and 3-point-bending tests, corrosion and its influence on the mechanical properties. Due to recrystallization during their complex forming processes (casting, extrusion, wire drawing), both wires show a fine grained microstructure resulting in high strength and ductility. However, the ductility is mostly evaluated by 3-point bending and compression; due to the notch effect in the clamp area, the maximum tensile strength and elongation under tension cannot be measured. Both alloys show a tensile-compressive yield asymmetry. Even RE-elements are known to reduce this asymmetry, the Mg-Gd alloy shows 100 MPa higher strength in tension than compression. The asymmetry of the Mg-Ag wire is similar. Overall the wires show very high strength and hardness, Mg6Ag slightly higher compared to Mg4Gd. Strong pitting corrosion is found and reduces strongly the tensile and bending strength.

  1. Wired to freedom

    DEFF Research Database (Denmark)

    Jepsen, Kim Sune Karrasch; Bertilsson, Margareta

    2017-01-01

    of cochlear implantations among Danish users in order to shed more light on their social and political implications. We situate cochlear implantation in a framework of new life science advances, politics, and user experiences. Analytically, we draw upon the notion of social imaginary and explore the social...... dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being “wired to freedom” that involves...... new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as “wired to freedom,” we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear...

  2. From Wires to Cosmology

    CERN Document Server

    Amin, Mustafa A

    2015-01-01

    We provide a statistical framework for characterizing stochastic particle production in the early universe via a precise correspondence to current conduction in wires with impurities. Our approach is particularly useful when the microphysics is uncertain and the dynamics are complex, but only coarse-grained information is of interest. We study scenarios with multiple interacting fields and derive the evolution of the particle occupation numbers from a Fokker-Planck equation. At late times, the typical occupation numbers grow exponentially which is the analog of Anderson localization for disordered wires. Some statistical features of the occupation numbers show hints of universality in the limit of a large number of interactions and/or a large number of fields. For test cases, excellent agreement is found between our analytic results and numerical simulations.

  3. Twisting wire scanner

    CERN Document Server

    Gharibyan, V; Krouptchenkov, I; Nölle, D; Tiessen, H; Werner, M; Wittenburg, K

    2012-01-01

    A new type of 'two-in-one' wire scanner is proposed. Recent advances in linear motors' technology make it possible to combine translational and rotational movements. This will allow to scan the beam in two perpendicular directions using a single driving motor and a special fork attached to it. Vertical or horizontal mounting will help to escape problems associated with the 45 deg scanners. Test results of the translational part with linear motors is presented.

  4. Magnetoconductance of quantum wires

    Science.gov (United States)

    Ferreira, Gerson J.; Sammarco, Filipe; Egues, Carlos

    2010-03-01

    At low temperatures the conductance of a quantum wires exhibit characteristic plate-aus due to the quantization of the transverse modes [1]. In the presence of high in-plane magnetic fields these spin-split transverse modes cross. Recently, these crossings were observed experimentally [2] via measurements of the differential conductance as a function of the gate voltage and the in-plane magnetic-field. These show structures described as either anti-crossings or magnetic phase transitions. Motivated by our previous works on magnetotransport in 2DEGs via the Spin Density Functional Theory (SDFT) [3], here we propose a similar model to investigate the magnetoconductance of quantum wires. We use (i) the SDFT via the Kohn-Sham self-consistent scheme within the local spin density approximation to obtain the electronic structure and (ii) the Landauer-Buettiker formalism to calculate the conductance of a quantum wire. Our results show qualitative agreement with the data of Ref. [2]. [1] B. J. van Wees et al., Phys. Rev. Lett. 60, 848 (1988). [2] A. C. Graham et al., Phys. Rev. Lett. 100, 226804 (2008). [3] H. J. P. Freire, and J. C. Egues, Phys. Rev. Lett. 99, 026801 (2007); G. J. Ferreira, and J. Carlos Egues, J. Supercond. Nov. Mag., in press; G. J. Ferreira, H. J. P. Freire, J. Carlos Egues, submitted.

  5. Bond Tension in Tethered Macromolecules.

    Science.gov (United States)

    Sheiko, Sergei S; Panyukov, Sergey; Rubinstein, Michael

    2011-06-14

    The paper presents scaling analysis of mechanical tension generated in densely branched macromolecules tethered to a solid substrate with a short linker. Steric repulsion between branches results in z-fold amplification of tension in the linker, where z is the number of chain-like arms. At large z ~ 100-1000, the generated tension may exceed the strength of covalent bonds and sever the linker. Two types of molecular architectures were considered: polymer stars and polymer "bottlebrushes" tethered to a solid substrate. Depending on the grafting density, one distinguishes the so-called mushroom, loose grafting, and dense grafting regimes. In isolated (mushroom) and loosely tethered bottlebrushes, the linker tension is by a factor of [Formula: see text] smaller than the tension in a tethered star with the same number of arms z. In densely tethered stars, the effect of interchain distance (d) and number of arms (z) on the magnitude of linker tension is given by f ≅ f0z(3/2)(b/d) for stars in a solvent environment and f ≅ f0z(2) (b/d)(2) for dry stars, where b is the Kuhn length and f0 ≅ kBT/b is intrinsic bond tension. These relations are also valid for tethered bottlebrushes with long side chains. However, unlike molecular stars, bottlebrushes demonstrate variation of tension along the backbone f ≅ f0s z(1/2) / d as a function of distance s from the free end of the backbone. In dense brushes [Formula: see text] with z ≅ 1000, the backbone tension increases from f ≅ f0 = 1 pN at the free end of the backbone (s ≅ b) to its maximum f ≅ zf0 ≅ 1 nN at the linker to the substrate (s ≅ zb).

  6. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  7. Giant bullae mimicking tension pneumothorax

    Directory of Open Access Journals (Sweden)

    Ahmet Erbey

    2012-12-01

    Full Text Available Giant bullae may mimic tension pneumothorax radiologicallyso that it may expand completely to hemithorax,increase of radiolucency mediastinal shift, flattening ofdiaphragm and printing on trachea. Sixty one year oldmale patient with giant bullae misdiagnosed as tensionpneumothorax and underwent to tube thoracostomy. Thedifferential diagnosis of giant bullae and tension pneumothoraxmay be confusing. The therapeutic approaches ofthese two radiologically similar entities differ significantly.Thus proper physical assessment and radiological examinationis crucial in the differential diagnosis and computedtomography examination should be performed before theadjustment of therapy. J Clin Exp Invest 2012; 3(4: 548-551Key words: Tension pneumothorax, giant bullae, computedtomography, tube thoracostomy

  8. Tensile test and interface retention forces between wires and composites in lingual fixed retainers.

    Science.gov (United States)

    Paolone, Maria Giacinta; Kaitsas, Roberto; Obach, Patricia; Kaitsas, Vasilios; Benedicenti, Stefano; Sorrenti, Eugenio; Barberi, Fabrizio

    2015-06-01

    In daily orthodontic clinical practice retention is very important, and lingual retainers are part of this challenge. The failure of lingual retainers may be due to many factors. The aim of this study was to assess the retention forces and mechanical behavior of different types of wires matched with different kinds of composites in lingual retainers. A tensile test was performed on cylindrical composite test specimens bonded to orthodontic wires. The specimens were constructed using four different wires: a straight wire (Remanium .016×.022″ Dentaurum), two round twisted wires (Penta One .0215″ Masel, Gold Penta Twisted .0215″ Gold N'braces) and a rectangular braided wire (D-Rect .016×.022″ Ormco); and three composites: two micro-hybrids (Micro-Hybrid Enamel Plus HFO Micerium, and Micro-Hybrid SDR U Dentsply) and a micro-nano-filled composite (Micro-Nano-Filled Transbond LR 3M). The test was performed at a speed of 10mm/min on an Inström device. The wire was fixed with a clamp. The results showed that the bonding between wires and composites in lingual fixed retainers seemed to be lowest for rectangular smooth wires and increased in round twisted and rectangular twisted wires where the bonding was so strong that the maximum tension/bond strength was greater than the ultimate tensile strength of the wire. The highest values were in rectangular twisted wires. Concerning the composites, hybrid composites had the lowest interface bonding values and broke very quickly, while the nano- and micro-composites tolerated stronger forces and displayed higher bonding values. The best results were observed with the golden twisted wire and reached 21.46 MPa with the Transbond composite. With the rectangular braided wire the retention forces were so high that the Enamel Plus composite fractured when the load exceeded 154.6 N/MPa. When the same wire was combined with the Transbond LR either the wire or the composite broke when the force exceeded 240 N. The results of this

  9. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    Science.gov (United States)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  10. Horizon Thermodynamics and Gravitational Tension

    CERN Document Server

    Widom, A; Srivastava, Y N

    2016-01-01

    We consider the thermodynamics of a horizon surface from the viewpoint of the vacuum tension $\\tau =(c^4/4G )$. Numerically, $\\tau \\approx 3.026\\times 10^{43}$ Newton. In order of magnitude, this is the tension that has been proposed for microscopic string models of gravity. However, after decades of hard work on string theory models of gravity, there is no firm scientific evidence that such models of gravity apply empirically. Our purpose is thereby to discuss the gravitational tension in terms of the conventional Einstein general theory of relativity that apparently does explain much and maybe all of presently known experimental gravity data. The central result is that matter on the horizon surface is bound by the entropy-area law by tension in the closely analogous sense that the Wilson action-area law also describes a surface confinement.

  11. THERMAL CONDUCTIVITY OF METALLIC WIRES

    Institute of Scientific and Technical Information of China (English)

    LU XIANG; GU JI-HUA; CHU JUN-HAO

    2001-01-01

    The effect of radial thickness on the thermal conductivity of a free standing wire is investigated. The thermal conductivity is evaluated using the Boltzmann equation. A simple expression for the reduction in conductivity due to the increase of boundary scattering is presented. A comparison is made between the experimental results of indium wires and the theoretical calculations. It is shown that this decrease of conductivity in wires is smaller than that in film where heat flux is perpendicular to the surface.

  12. Subminiature Hot-Wire Probes

    Science.gov (United States)

    Westphal, R. V.; Lemos, F. R.; Ligrani, P. M.

    1989-01-01

    Class of improved subminiature hot-wire flow-measuring probes developed. Smaller sizes yield improved resolution in measurements of practical aerodynamic flows. Probe made in one-wire, two-perpendicular-wire, and three-perpendicular-wire version for measurement of one, two, or all three components of flow. Oriented and positioned on micromanipulator stage and viewed under microscope during fabrication. Tested by taking measurements in constant-pressure turbulent boundary layer. New probes give improved measurements of turbulence quantities near surfaces and anisotropies of flows strongly influence relative errors caused by phenomena related to spatial resolution.

  13. Plasma Formation Around Single Wires

    Science.gov (United States)

    Duselis, Peter U.; Kusse, Bruce R.

    2002-12-01

    At Cornell's Laboratory of Plasma Studies, single wires of various metals were exploded using a ˜250 ns pulser with a rise time of ˜20 A/ns. It was found that the wires first experience a resistive heating phase that lasts 50-80 ns before a rapid collapse of voltage. From that point on, the voltage across the wire was negligible while the current through the wire continued to increase. We attribute this voltage collapse to the formation of plasma about the wire. Further confirmation of this explanation will be presented along with new experimental data describing preliminary spectroscopy results, the expansion rate of the plasma, and current flow along the wire as a function of radius. The resistance of the wire-electrode connection will be shown to significantly affect the energy deposition. Various diagnostics were used to obtain these experiments. Ultraviolet sensitive vacuum photodiodes and a framing camera with an 8 ns shutter were used to detect and measure the width of the visible light emitted by the plasma. A special wire holder was constructed that allowed the transfer of current from the wire to the surrounding plasma to be observed.

  14. Texture development in Galfenol wire

    Science.gov (United States)

    Boesenberg, A. J.; Restorff, J. B.; Wun-Fogle, M.; Sailsbury, H.; Summers, E.

    2013-05-01

    Galfenol (Fe-Ga alloy) wire fabrication provides a low cost alternative to directional solidification methods. This work evaluates the compositional dependence of the wire drawing suitability of Fe-Ga and characterizes the microstructural and magnetic properties of these wires. Wire has been produced with Ga contents between 10 at. % and 17 at. % to allow determination of the ductile to brittle transition (DTBT) in wire manufacture. Published results on chill cast bend specimens indicated that a DTBT occurs at roughly 15 at. % Ga. This DTBT was observed under tensile loading with a corresponding change in fracture behavior from transverse fracture to intergranular fracture. For improved magnetostrictive performance, higher Ga contents are desired, closer to the 17 at. % Ga evaluated in this work. Electron backscattered diffraction B-H loop and resonance measurements as a function of magnetic field (to determine modulus and coupling factor) are presented for as-drawn, furnace, and direct current (DC) annealed wire. Galfenol wire produced via traditional drawing methods is found to have a strong (α) texture parallel to the drawing direction. As-drawn wire was observed to have a lower magnetic permeability and larger hysteresis than DC annealed wire. This is attributed to the presence of a large volume of crystalline defects; such as vacancies and dislocations.

  15. Wiring regulations in brief

    CERN Document Server

    Tricker, Ray

    2012-01-01

    Tired of trawling through the Wiring Regs?Perplexed by Part P?Confused by cables, conductors and circuits?Then look no further! This handy guide provides an on-the-job reference source for Electricians, Designers, Service Engineers, Inspectors, Builders, Students, DIY enthusiastsTopic-based chapters link areas of working practice - such as cables, installations, testing and inspection, special locations - with the specifics of the Regulations themselves. This allows quick and easy identification of the official requirements relating to the situati

  16. WAYS TO INCREASE PLASTIC PROPERTIES OF A WIRE IN THE CONDITIONS OF DRAWING OF HARDWARE PRODUCTION OF JSC «BSW MANAGEMENT COMPANY OF HOLDING «ВМС»

    Directory of Open Access Journals (Sweden)

    S. V. Voytenkov

    2015-01-01

    Full Text Available During production of a wire of high groups of durability the problem of ensuring rather high level of ductility is actual. One of options for the prevention of embrittlement of a wire and as, the consequence, increases of plastic properties is use of the device of stabilization of internal tension in a wire. The guidestraightener device improves redistribution of the stretching tension in wire blankets by means of a sign-variable bend. The device of stabilization of internal tension in a wire finds the increasing practical application in the conditions of drawing shop of JSC BSW-management Company of Holding BMC and shows positive results on decrease in number of attacks on reversible twisting.

  17. Corrosion of Wires on Wooden Wire-Bound Packaging Crates

    Science.gov (United States)

    Samuel L. Zelinka; Stan Lebow

    2015-01-01

    Wire-bound packaging crates are used by the US Army to transport materials. Because these crates may be exposed to harsh environments, they are dip-treated with a wood preservative (biocide treatment). For many years, zinc-naphthenate was the most commonly used preservative for these packaging crates and few corrosion problems with the wires were observed. Recently,...

  18. Primarily nonlinear effects observed in a driven asymmetrical vibrating wire

    Science.gov (United States)

    Hanson, Roger J.; Macomber, H. Kent; Morrison, Andrew C.; Boucher, Matthew A.

    2005-01-01

    The purpose of the work reported here is to further experimentally explore the wide variety of behaviors exhibited by driven vibrating wires, primarily in the nonlinear regime. When the wire is driven near a resonant frequency, it is found that most such behaviors are significantly affected by the splitting of the resonant frequency and by the existence of a ``characteristic'' axis associated with each split frequency. It is shown that frequency splitting decreases with increasing wire tension and can be altered by twisting. Two methods are described for determining the orientation of characteristic axes. Evidence is provided, with a possible explanation, that each axis has the same orientation everywhere along the wire. Frequency response data exhibiting nonlinear generation of transverse motion perpendicular to the driving direction, hysteresis, linear generation of perpendicular motion (sometimes tubular), and generation of motion at harmonics of the driving frequency are exhibited and discussed. Also reported under seemingly unchanging conditions are abrupt large changes in the harmonic content of the motion that sometimes involve large subharmonics and harmonics thereof. Slow transitions from one stable state of vibration to another and quasiperiodic motions are also exhibited. Possible musical significance is discussed. .

  19. Soft magnetic wires

    Science.gov (United States)

    Vázquez, M.

    2001-06-01

    An overview of the present state of the art on the preparation techniques, outstanding magnetic properties and applications of soft magnetic micro and nanowires is presented. Rapid solidification techniques (in-rotating-water quenching and drawing methods) to fabricate amorphous microwires with diameter in the range from 100 down to 1 μm are first described. Electrodeposition is also employed to prepare composite microtubes (magnetic coatings) and to fill porous membranes (diameter of the order of 0.1 μm). Magnetic behaviours of interest are related to the different hysteresis loops of samples: square-shaped loops typical of bistable behaviour, and nearly non-hysteretic loop with well-defined transverse anisotropy field. The role played by magnetic dipolar interactions in the magnetic behaviour of arrays of micro and nanowires is described. A particular analysis is done on the giant magnetoimpedance (GMI) effect in the radio and microwave frequency ranges exhibited by ultrasoft microwires. Finally, a few examples of applications are introduced for magnetostrictive and non-magnetostrictive wires, they are: “magnetoelastic pens”, micromotors; DC current-sensors based on GMI, and sharpened amorphous wire tips in spin polarised scanning tunneling microscopy.

  20. MACHINABILTY OF SLEIPNER COLD WORK STEEL WITH WIRE ELECTRO DISCHARGE MACHINING

    Directory of Open Access Journals (Sweden)

    Iskender OZKUL

    2013-01-01

    Full Text Available Machining techniques in the industry generally, modern processing techniques, that come between wire discharging machine, especially mold, defense, aircraft and aerospace industry, is often used. Processing, which is difficult with conventional manufacturing methods, the complex surface forms, the different material types, hard and is capable of handling high dimensional accuracy and surface roughness [1]. This manufacturing technique were carried on Uddeholm Sleipner cold-work tool steel, variable parameters with On time duration, feed rate, and the current value, as fixed parameters off time duration, voltage, pressure of fluid circulation, velocity of wire, wire tension and wire diameter. Surface roughness of the surface was shown changes as a result of the experimental parameters, diameter and circularity deviation values were studied.

  1. BEPC II wire scanner system

    Institute of Scientific and Technical Information of China (English)

    SUI Yan-Feng; WANG Lin; ZHAO Ying; YUE Jun-Hui; LI Xiao-Ping; CAO Jian-She; MA Li

    2010-01-01

    To monitor the beam profile at the end of the linac non-destructively,a wire scanner as a new diagnostic instrument was designed,manufactured and installed in 2007.Since then,several measurements have been carried out using this device.This paper describes the whole system of the wire scanner and the testing results.

  2. Wire and Packing Tape Sandwiches

    Science.gov (United States)

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  3. Crystallographic Texture Difference Between Center and Sub-Surface of Thin Cold-Drawn Pearlitic Steel Wires

    Science.gov (United States)

    Zhao, Tian-Zhang; Zhang, Guang-Liang; Song, Hong-Wu; Cheng, Ming; Zhang, Shi-Hong

    2014-09-01

    The texture difference between the center and sub-surface of pearlitic steel wires, which were manufactured by continuous cold drawing, was investigated by orientation distribution function based on electron back-scattered diffraction at different drawing passes. A perfect fiber texture parallel to drawing direction develops gradually with drawing strain increasing at the wire center, while at the sub-surface, a quasi fiber texture with the orientation nearly parallel to the circumferential direction is found. This texture at the sub-surface is softer than the perfect fiber texture in tension. The reasons for this texture difference and influences on the wire's mechanical properties are discussed.

  4. Wire metamaterials: physics and applications.

    Science.gov (United States)

    Simovski, Constantin R; Belov, Pavel A; Atrashchenko, Alexander V; Kivshar, Yuri S

    2012-08-16

    The physics and applications of a broad class of artificial electromagnetic materials composed of lattices of aligned metal rods embedded in a dielectric matrix are reviewed. Such structures are here termed wire metamaterials. They appear in various settings and can operate from microwaves to THz and optical frequencies. An important group of these metamaterials is a wire medium possessing extreme optical anisotropy. The study of wire metamaterials has a long history, however, most of their important and useful properties have been revealed and understood only recently, especially in the THz and optical frequency ranges where the wire media correspond to the lattices of microwires and nanowires, respectively. Another group of wire metamaterials are arrays and lattices of nanorods of noble metals whose unusual properties are driven by plasmonic resonances. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. FIRAS wire grid characterization techniques

    Science.gov (United States)

    Barney, Richard D.; Magner, Thomas J.

    1989-01-01

    Characterization techniques used to verify the quality and spectral performance of the large freestanding wire grid polarizing beamsplitters and input/output polarizers used in the Far Infrared Absolute Spectrophotometer (FIRAS) are presented. The clear aperture of these grids is lined with 20.8 micron diameter gold coated tungsten wire, spaced 33 microns apart. The grid characteristics measured throughout fabrication and space flight qualification are the center to center wire spacing and wire plane flatness. Ideally, the wire grids should produce coherent wavefronts with equal reflectance and transmittance properties. When the spacing is inconsistent, these wavefront intensities are unequal, thus decreasing the efficiency of the grids and reducing the output signal of the FIRAS. The magnitude of the output interferogram is also reduced by incoherence in the interfering wave fronts caused by uneven flatness.

  6. Cosmic Strings with Small Tension

    CERN Document Server

    Halyo, Edi

    2009-01-01

    We describe cosmic F--term strings with exponentially small tension which are D3 branes wrapped on deformed $A_3$ singularities. We show that brane instanton effects which can be calculated after a geometric transition give rise to an exponentially small volume for the node on which the D3 branes wrap leading to a string with small tension. We generalize our description to the case of non--Abelian cosmic strings and argue that these strings are stable against monopole--anti monopole pair creation.

  7. Nano-storage wires.

    Science.gov (United States)

    Lee, Dong Jun; Kim, Eunji; Kim, Daesan; Park, Juhun; Hong, Seunghun

    2013-08-27

    We report the development of "nano-storage wires" (NSWs), which can store chemical species and release them at a desired moment via external electrical stimuli. Here, using the electrodeposition process through an anodized aluminum oxide template, we fabricated multisegmented nanowires composed of a polypyrrole segment containing adenosine triphosphate (ATP) molecules, a ferromagnetic nickel segment, and a conductive gold segment. Upon the application of a negative bias voltage, the NSWs released ATP molecules for the control of motor protein activities. Furthermore, NSWs can be printed onto various substrates including flexible or three-dimensional structured substrates by direct writing or magnetic manipulation strategies to build versatile chemical storage devices. Since our strategy provides a means to store and release chemical species in a controlled manner, it should open up various applications such as drug delivery systems and biochips for the controlled release of chemicals.

  8. 切割钢丝用收线机的研制%Development of take-up for saw wire

    Institute of Scientific and Technical Information of China (English)

    张德强

    2013-01-01

    针对切割钢丝在收线过程中随卷径增大出现的张力波动问题,以及排线的恒间距要求,研制出双变频控制收线、伺服器控制排线的收线机.该收线机由张力摆杆装置、排线装置、收卷装置及电气控制系统组成,说明各组成部分的功能及原理,给出整机结构示意图、控制系统框图.收线采用具有卷径计算功能的台达变频器驱动,排线采用台达ASDA-AB伺服器控制,实现了排线间距恒定、收线张力恒定,解决了切割钢丝在收卷过程中张力稳定和排线平整问题.%Take-up with dual frequency conversion control spooling and server control wiring was developed aiming at the tension fluctuation problem occurred with coil diameter increasing of saw wire in spooling process and the constant spacing requirement of winding. The take-up consists of tension of the rocker device, wire laying device, take-up device and electric control system. The function and principle of each component is illustrated, the whole machine structure diagram and control system diagram is given. The take-up is driven by adopting Delta inverter with coil diameter calculation function, wire laying is controlled by adopting Delta ASDA - AB server, the wire laying spacing constant and take-up tension constant are realized, the problem of saw wire tension steady and wire laying neat in coil process is solved.

  9. Robotic patch-stabilizer using wire driven mechanism for minimally invasive fetal surgery.

    Science.gov (United States)

    Zhang, Bo; Kobayashi, Yo; Chiba, Toshio; Fujie, Masakatsu G

    2009-01-01

    The clinical target of this study is intrauterine patch coverage of fetal myelomeningocele. We propose a new surgical robotic system for intrauterine fetal surgery with patch-stabilizer and laser manipulator. The target disease of the fetal surgery is spina bifida or myelomeningocele, which is incomplete closure in the spinal column and one of the common fetal diseases. In the fetal surgery, the collagen patch is supposed to be stabilized onto the fragile fetal tissue during the laser fixation process. In this study, a prototype of the patch-stabilizer using wire driven mechanism has been developed for precise force control on the patch without damaging fetal tissue. The diameter of the patch-stabilizer's shaft is 2.4 mm. The patch-stabilizer including one ball joint and wire driven mechanism is able to bend through 40 degrees. The stabilizing part holds collagen patch with diamond shape mechanism using wire driven. In this paper, we showed that the patch-stabilizer is developed with the stabilizing force control using the tension control of wires. Results of the experiment showed that the tension of driven wires was controlled at 0.3 N to stabilize the collagen patch onto the lesion surface without the damages of fetal tissues and the influence by the amnion liquid.

  10. Plasma chemistry in wire chambers

    Energy Technology Data Exchange (ETDEWEB)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed.

  11. AUTOGENIC THERAPY IN TENSION HEADACHE

    OpenAIRE

    Amruthraj, Brunda; Mishra, H.; Kumaraiah, V.

    1987-01-01

    SUMMARY Ten subjects diagnosed as Psychalgia were taken for study. A multiple baseline design was adapted and clients were subjected to 30 sessions of autogenic training. They were assessed using physiological (EMG and thermal change) and behavioural measures (Visual analogue scale and behavioural symptom checklist). Findings revealed autogenic therapy to be effective in reducing tension headache.

  12. Tension type headaches: a review

    African Journals Online (AJOL)

    23. Epidemiology. A wide variation in the prevalence of tension-type headaches .... intensity tending to be less in the morning, building up after noon, and reducing ... with a change in position or the start of Valsalva-like sneezing. • Associated ...

  13. Abolishing the maximum tension principle

    CERN Document Server

    Dabrowski, Mariusz P

    2015-01-01

    We find the series of example theories for which the relativistic limit of maximum tension $F_{max} = c^2/4G$ represented by the entropic force can be abolished. Among them the varying constants theories, some generalized entropy models applied both for cosmological and black hole horizons as well as some generalized uncertainty principle models.

  14. Abolishing the maximum tension principle

    Directory of Open Access Journals (Sweden)

    Mariusz P. Da̧browski

    2015-09-01

    Full Text Available We find the series of example theories for which the relativistic limit of maximum tension Fmax=c4/4G represented by the entropic force can be abolished. Among them the varying constants theories, some generalized entropy models applied both for cosmological and black hole horizons as well as some generalized uncertainty principle models.

  15. CALCULATION OF TENSION FORCE OF BELT CONVEYOR

    Directory of Open Access Journals (Sweden)

    Ismet Ibishi

    2012-12-01

    Full Text Available In this paper is done the explanation on tension fashion of the belt conveyor which is employed in Kosovo Energy Corporation – KEK, for coal transportation to provide electric power plant. The aim of the paper enables to recognize tension forces not to pass with deformation of belt so that this problem will damage the workingprocess. Work principle is based on initial tension and tension during working process. The fact is known that the tension starts from the carriage on the way to tension mechanization, so forces on the rope passing through pulley there has to dominate the friction coefficient. All this process is related to economy of transportationmechanism.

  16. Influence of Flaws of Wire Rod Surface, Inclusions and Voids on Wire Breaks in Superfine Wire Drawing

    Science.gov (United States)

    Yoshida, Kazunari; Norasethasopon, Somchai; Shinohara, Tetsuo; Ido, Ryuta

    By means of the finite element analysis (FEA), this study analyzed wire breaks that occurred in the drawing fine wires containing flaws on the wire surface, inclusion and void. The deformation behavior of an inclusion was examined, in which the inclusion's location is assumed to be on the center axis of the wire, and the cause of wire breaks and their prevention method were clarified. It was found that an inclusion diameter/wire diameter ratio of 0.4 or higher increases the likelihood of wire breaks occurring. When the inclusion is not assumed to be in the center axis of the wire, it was also found that necking and wire breaks appear more frequently. FEA showed that a flaw grows with each processing step, when a small circumferential flaw is placed on the wire rod surface, and eventually becomes a surface defect, which is called a check mark in practice.

  17. Cavity Mode Related Wire Breaking of the SPS Wire Scanners and Loss Measurements of Wire Materials

    CERN Document Server

    Caspers, Friedhelm; Jensen, E; Koopman, J; Malo, J F; Roncarolo, F

    2003-01-01

    During the SPS high intensity run 2002 with LHC type beam, the breaking of several of the carbon wires in the wire scanners has been observed in their parking position. The observation of large changes in the wire resistivity and thermionic electron emission clearly indicated strong RF heating that was depending on the bunch length. A subsequent analysis in the laboratory, simulating the beam by two probe antennas or by a powered stretched wire, showed two main problems: i) the housing of the wire scanner acts as a cavity with a mode spectrum starting around 350 MHz and high impedance values around 700 MHz; ii) the carbon wire used so far appears to be an excellent RF absorber and thus dissipates a significant part of the beam-induced power. Different wire materials are compared with the classical cavity mode technique for the determination of the complex permittivity in the range of 2-4 GHz. As a resonator a rectangular TE_01n type device is utilized.

  18. Cavity mode related wire breaking of the SPS Wire Scanners and loss measurements of wire materials

    CERN Document Server

    Roncarolo, Federico

    2003-01-01

    During the SPS high intensity run 2002 with LHC type beam, the breaking of several of the carbon wires in the wire scanners has been observed in their parking position. The observation of large changes in the wire resistivity and thermionic electron emission clearly indicated strong RF heating that was depending on the bunch length. A subsequent analysis in the laboratory, simulating the beam by two probe antennas or by a powered stretched wire, showed two main problems: i) the housing of the wire scanner acts as a cavity with a mode spectrum starting around 350MHz and high impedance values around 700 MHz; ii) the carbon wire used so far appears to be an excellent RF absorber and thus dissipates a significant part of the beam-induced power. Different wire materials are compared with the classical cavity mode technique for the determination of the complex permittivity in the range of 2-4 GHz. As a resonator a rectangular TE01n type device is utilized.

  19. "Cut wires grating – single longitudinal wire" planar metastructure to achieve microwave magnetic resonance in a single wire

    OpenAIRE

    G. Kraftmakher; V. Butylkin

    2012-01-01

    Here we present metastructures containing cut-wire grating and a single longitudinal cut-wire orthogonal to grating’s wires. Experimental investigations at microwaves show these structures can provide strong magnetic resonant response of a single nonmagnetic cut-wire in dependence on configuration and sizes in the case when metastructures are oriented along the direction of wave propagation and cut-wires of grating are parallel to the electric field of a plane electromagnetic wave. It is sugg...

  20. Superconducting wires and fractional flux

    Science.gov (United States)

    Sá de Melo, C. A. R.

    1996-05-01

    The quantization of flux quanta in superconductors is revisited and analyzed in a new geometry. The system analyzed is a superconducting wire. The geometry is such that the superconducting wire winds N times around an insulating cylinder and that the wire has its end connected back to its beginning, thus producing an N-loop short circuited solenoid. The winding number N acts as a topological index that controls flux quantization. In this case, fractional flux quanta can be measured through the center of the insulating cylinder, provided that the cylinder radius is small enough. The Little-Parks experiment for an identical geometry is discussed. The period of oscillation of the transition temperature of the wire is found to vary as 1/N in units of flux Φ relative to the flux quantum Φ0. When a SQUID is made in such a geometry the maximal current through the SQUID varies with period Φ0/N.

  1. Wire Jewelry/Black History.

    Science.gov (United States)

    Daniel, Robert A.; Robinson, Charles C.

    1984-01-01

    Described is a project which made the study of Black history more real to fifth graders by having them make wire jewelry, smaller versions of the ornate filigreed ironwork produced by slave blacksmiths. (RM)

  2. Dieless wire drawing with lasers

    Science.gov (United States)

    Liedl, G.; Schuöcker, D.

    2007-06-01

    Thin wires are produced by drawing through nozzle-like tools, so called dies, that suffer from strong wear due to friction. In order to avoid the latter disadvantage the dies can be replaced by a laser beam heating the wire to such extend that the yield strength becomes smaller than the tensile strength and thus the wire is elongated and consequently constricted. To avoid rupture, the wire is cooled down again after the desired reduction of the diameter is reached. A further important advantage of this new process is that only one drawing step with a laser can substitute a large number of mechanical drawing actions, thus making the process much more efficient. Theoretical considerations and experimental investigations prove the feasibility of the latter new laser process and are subject to a description in the actual paper.

  3. 49 CFR 236.74 - Protection of insulated wire; splice in underground wire.

    Science.gov (United States)

    2010-10-01

    ... underground wire. 236.74 Section 236.74 Transportation Other Regulations Relating to Transportation (Continued... wire; splice in underground wire. Insulated wire shall be protected from mechanical injury. The insulation shall not be punctured for test purposes. Splice in underground wire shall have insulation...

  4. 49 CFR 234.241 - Protection of insulated wire; splice in underground wire.

    Science.gov (United States)

    2010-10-01

    ... underground wire. 234.241 Section 234.241 Transportation Other Regulations Relating to Transportation... of insulated wire; splice in underground wire. Insulated wire shall be protected from mechanical injury. The insulation shall not be punctured for test purposes. A splice in underground wire shall have...

  5. Composite conductor containing superconductive wires

    Energy Technology Data Exchange (ETDEWEB)

    Larson, W.L.; Wong, J.

    1974-03-26

    A superconductor cable substitute made by coworking multiple rods of superconductive niobium--titanium or niobium--zirconium alloy with a common copper matrix to extend the copper and rods to form a final elongated product which has superconductive wires distributed in a reduced cross-section copper conductor with a complete metallurgical bond between the normal-conductive copper and the superconductor wires contained therein is described. The superconductor cable can be in the form of a tube.

  6. Method of manufacturing superconductor wire

    Science.gov (United States)

    Motowidlo, Leszek

    2014-09-16

    A method for forming Nb.sub.3Sn superconducting wire is provided. The method employs a powder-in-tube process using a high-tin intermetallic compound, such as MnSn.sub.2, for producing the Nb.sub.3Sn. The use of a high-tin intermetallic compound enables the process to perform hot extrusion without melting the high-tin intermetallic compound. Alternatively, the method may entail drawing the wire without hot extrusion.

  7. Topology Optimized Photonic Wire Splitters

    DEFF Research Database (Denmark)

    Frandsen, Lars Hagedorn; Borel, Peter Ingo; Jensen, Jakob Søndergaard;

    2006-01-01

    Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm.......Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm....

  8. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  9. HTS Wire Development Workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  10. Wire Scanner Motion Control Card

    CERN Document Server

    Forde, S E

    2006-01-01

    Scientists require a certain beam quality produced by the accelerator rings at CERN. The discovery potential of LHC is given by the reachable luminosity at its interaction points. The luminosity is maximized by minimizing the beam size. Therefore an accurate beam size measurement is required for optimizing the luminosity. The wire scanner performs very accurate profile measurements, but as it can not be used at full intensity in the LHC ring, it is used for calibrating other profile monitors. As the current wire scanner system, which is used in the present CERN accelerators, has not been made for the required specification of the LHC, a new design of a wire scanner motion control card is part of the LHC wire scanner project. The main functions of this card are to control the wire scanner motion and to acquire the position of the wire. In case of further upgrades at a later stage, it is required to allow an easy update of the firmware, hence the programmable features of FPGAs will be used for this purpose. The...

  11. Vibrating wires for beam diagnostics

    CERN Document Server

    Arutunian, S G; Wittenburg, Kay

    2015-01-01

    A new approach to the technique of scanning by wires is developed. Novelty of the method is that the wire heating quantity is used as a source of information about the number of interacting particles. To increase the accuracy and sensitivity of measurements the wire heating measurement is regenerated as a change of wire natural oscillations frequency. By the rigid fixing of the wire ends on the base an unprecedented sensitivity of the frequency to the temperature and to the corresponding flux of colliding particles. The range of used frequencies (tens of kHz) and speed of processes of heat transfer limit the speed characteristics of proposed scanning method, however, the high sensitivity make it a perspective one for investigation of beam halo and weak beam scanning. Traditional beam profile monitors generally focus on the beam core and loose sensitivity in the halo region where a large dynamic range of detection is necessary. The scanning by a vibrating wire can be also successfully used in profiling and det...

  12. Connecting to Thermocouples with Fewer Lead Wires

    Science.gov (United States)

    Goldsby, Jon C.

    2003-01-01

    A simple technique has been devised to reduce the number of lead wires needed to connect an array of thermocouples to the instruments (e.g., voltmeters) used to read their output voltages. Because thermocouple wires are usually made of expensive metal alloys, reducing the number of lead wires can effect a considerable reduction in the cost of such an array. Reducing the number of wires also reduces the number of terminals and the amount of space needed to accommodate the wires.

  13. Tensions of Corporate Social Responsibility

    DEFF Research Database (Denmark)

    Strand, Robert

    I engaged with the top management team (TMT) and employees of American Cafes Corporation as an action/intervention researcher in the 20 months immediately following the TMT’s decision to formalize the company’s corporate social responsibility (CSR) activities. This led to the establishment...... CSR agenda is considered, which brings with it a multiplicity of substantively rational ends for which the corporation could pursue. I show the CSR bureaucracy can create a space for reflection in which the multiplicity of substantively rational ends can be considered, negotiated, and selected...... for reflection within the corporation. But I also show tensions can arise from the establishment of the CSR bureaucracy itself. This suggests the CSR bureaucracy itself resides in a tension....

  14. Introducing surface tension to spacetime

    Science.gov (United States)

    Perko, H. A.

    2017-05-01

    Concepts from physical chemistry of surfaces and surface tension are applied to spacetime. More specifically, spacetime is modeled as a spatial fluid continuum bound together by a multi-dimensional membrane of time. A metric tensor that relates empty flat spacetime to energetic curved spacetime is found. Equations of motion for an infinitesimal unit of spacetime are derived. The equation of motion in a time-like direction is a Klein-Gordon type equation. The equations of motion in space-like directions take the form of Schrodinger’s equation where Plank’s constant is related to membrane elastic modulus. Although much work remains, it is suggested that the spacetime surface tension may serve as a mechanical model for many phenomena in quantum mechanics and atomic particle physics.

  15. Robust Tensioned Kevlar Suspension Design

    Science.gov (United States)

    Young, Joseph B.; Naylor, Bret J.; Holmes, Warren A.

    2012-01-01

    One common but challenging problem in cryogenic engineering is to produce a mount that has excellent thermal isolation but is also rigid. Such mounts can be achieved by suspending the load from a network of fibers or strings held in tension. Kevlar fibers are often used for this purpose owing to their high strength and low thermal conductivity. A suite of compact design elements has been developed to improve the reliability of suspension systems made of Kevlar.

  16. Californium Recovery from Palladium Wire

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Jon D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-08-01

    The recovery of 252Cf from palladium-252Cf cermet wires was investigated to determine the feasibility of implementing it into the cermet wire production operation at Oak Ridge National Laboratory’s Radiochemical Engineering Development Center. The dissolution of Pd wire in 8 M HNO3 and trace amounts of HCl was studied at both ambient and elevated temperatures. These studies showed that it took days to dissolve the wire at ambient temperature and only 2 hours at 60°C. Adjusting the ratio of the volume of solvent to the mass of the wire segment showed little change in the kinetics of dissolution, which ranged from 0.176 mL/mg down to 0.019 mL/mg. A successful chromatographic separation of 153Gd, a surrogate for 252Cf, from Pd was demonstrated using AG 50x8 cation exchange resin with a bed volume of 0.5 mL and an internal diameter of 0.8 cm.

  17. Californium Recovery from Palladium Wire

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Jon D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-08-01

    The recovery of 252Cf from palladium-252Cf cermet wires was investigated to determine the feasibility of implementing it into the cermet wire production operation at Oak Ridge National Laboratory’s Radiochemical Engineering Development Center. The dissolution of Pd wire in 8 M HNO3 and trace amounts of HCl was studied at both ambient and elevated temperatures. These studies showed that it took days to dissolve the wire at ambient temperature and only 2 hours at 60°C. Adjusting the ratio of the volume of solvent to the mass of the wire segment showed little change in the kinetics of dissolution, which ranged from 0.176 mL/mg down to 0.019 mL/mg. A successful chromatographic separation of 153Gd, a surrogate for 252Cf, from Pd was demonstrated using AG 50x8 cation exchange resin with a bed volume of 0.5 mL and an internal diameter of 0.8 cm.

  18. Selected properties of GlidCop® sheathed MgB2 wires

    Science.gov (United States)

    Kováč, P.; Melišek, T.; Kopera, L.; Kováč, J.; Hušek, I.

    2012-09-01

    GlidCop® sheathed MgB2 wires containing 1-30 filaments have been manufactured by a powder-in-tube process. Two materials (Nb or Ti) have been used for barriers protecting the filaments against the diffusion of copper. Different deformations (drawing, rolling, rotary swaging and isostatic pressing) have been applied to the 30-filament wires prior to the final heat treatment. Critical current densities, Jc, were measured at low external magnetic fields including the self-field and at temperatures from 4.2 to 20 K by a short pulse currents. This allows a detailed pinning force analysis to be made, which has not been done up to now from the transport current data. The resistance of 1-30 filament wires against axial tensile stress has also been examined at 4.2 K. It was found that filament density influences not only the transport Jc but also the resistance to tension stress. While an increased filament density improves Jc the opposite effect has been found for resistance to axial tension. AC losses measured by a calibration-free technique of non-twisted wires have shown the dominant effect of the filament architecture and critical current densities.

  19. Microstructure and mechanical behavior of an as-drawn MP35N alloy wire

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, M.J.N.V. [School of Engineering, Brown University, Providence, RI 02912 (United States); Reiterer, M.W. [Medtronic Incorporated, Science and Technology, Minneapolis, MN 55432 (United States); Kumar, K.S., E-mail: Sharvan_Kumar@brown.edu [School of Engineering, Brown University, Providence, RI 02912 (United States)

    2014-07-29

    The deformation response of low Ti (<0.1%), MP35N alloy (35% Co–35% Ni–20% Cr–10% Mo, all in wt%) wire with a ∼100 µm diameter was assessed in monotonic and cyclic loading modes. The as-drawn wire exhibited a strong 〈111〉 fiber texture and consisted of a hierarchically twinned microstructure with twins spanning the micrometer to nanometer scale; when deformed in this condition in uniaxial tension at room temperature, high strengths up to 2 GPa, limited tensile ductility of 3% and strain rate sensitivity in the quasi-static regime were noted. The deformed microstructure revealed evidence for slip, twinning and de-twinning, and in the necked region, in the vicinity where fracture had occurred, the fine twins appeared broken down into nanograins. The cyclic response of the as-drawn wire, evaluated using rotary beam bending (R=−1) and in tension–tension fatigue (R=0.3), appeared to be initiation-controlled and sensitive to the presence of extraneous second phase inclusions identified as Al{sub 2}O{sub 3} particles. Cyclically-deformed as{sub -}drawn wire samples displayed extensive de-twinning and multiple twin variants formation.

  20. Axelrod's Model with Surface Tension

    CERN Document Server

    Pace, Bruno

    2012-01-01

    In this work we propose a subtle change in Axelrod's model for the dissemination of culture. The mechanism consists of excluding non-interacting neighbours from the set of neighbours out of which an agent is drawn for potential cultural interactions. Although the alteration proposed does not alter topologically the configuration space, it yields significant qualitative changes, specifically the emergence of surface tension, driving the system in some cases to metastable states. The transient behaviour is considerably richer, and cultural regions have become stable leading to the formation of different spatio-temporal structures. A new metastable "glassy" phase emerges between the globalised phase and the polarised, multicultural phase.

  1. Influence of the skin effect and current risetime on the fragmentation of wires by pulsed currents

    Science.gov (United States)

    Wall, D. P.; Allen, J. E.; Molokov, S.

    2005-07-01

    This study considers the physical phenomenon whereby wires may fragment in the solid state when subject to a sufficiently high pulsed electric current. A mathematical model is constructed within continuum mechanics which considers both Lorentz force and thermal mechanisms for the creation of stress waves in a wire. Previous studies are extended by including the skin effect, that is allowing for the diffusion of current density across the wire, and also investigating the influence of current risetime. Axisymmetric solutions are sought for rigid-lubricated, clamped, and free wire ends. Analytical solutions are obtained for the case of rigid-lubricated wire ends, while for the other cases the governing equations are solved numerically using an application-specific explicit finite-difference scheme, which is staggered in time and space. The inclusion of the skin effect leads to significant qualitative and quantitative differences in results. For example, in some cases we find tension in the longitudinal (τzz) stress component, which experiments suggest to be responsible for the fragmentation process, while the uniform-current model predicts compression. In most cases, the inclusion of the skin effect leads to higher peak tensile τzz stresses. Some understanding of the present results is gained with reference to analytical quasistatic solutions. Stresses generated by the Lorentz force mechanism are found to be more sensitive than those generated by the thermal mechanism to the current risetime. In both cases axial stresses increase with decreasing current risetime. Despite the differences in the results obtained with the inclusion of the skin effect, our results support the broad conclusions of the uniform-current model results; the largest stresses are found at the clamps for a wire with clamped ends, while the largest stresses in a wire with free ends are generated by the thermal mechanism and are located at the center of the wire.

  2. Flexible tension sensor based on poly(l-lactic acid) film with coaxial structure

    Science.gov (United States)

    Yoshida, Mitsunobu; Onishi, Katsuki; Tanimoto, Kazuhiro; Nishikawa, Shigeo

    2017-10-01

    We have developed a tension sensor with a coaxial structure using a narrow slit ribbon made of a uniaxially stretched poly(l-lactic acid) (PLLA) film for application to a wearable device. The tension sensor is produced as follows. We used tinsel wire as the center conductor of the sensor. The tinsel wire consists of a yarn of synthetic fibers arranged at the center, with a spirally wound rolled copper foil ribbon on the side surface. Next, slit ribbons obtained from a uniaxially oriented film of PLLA are wound helically on the side surface of the center conductor in the direction of a left-handed screw, at an angle of 45° to the central axis. The rolled copper foil is used as an outer conductor and covers the yarn without a gap. The prototype of the fabricated tension sensor has good flexibility, since the sensor is in the form of a filament and consists of a highly flexible material. For the 1 mm tension sensor, it was found that for a tension of 1 N, a charge of 14 pC was output. It was also found that the sensor maintained its room-temperature sensitivity up to 60 °C. Compared with an existing coaxial line sensor using poly(vinylidene fluoride) (PVDF), the sensor using PLLA does not exhibit pyroelectricity, meaning that no undesirable voltage is generated when in contact with body heat, which is a significant advantage as wearable sensors. The result has demonstrated the potential application of the PLLA film to wearable devices for detecting heartbeat and respiration.

  3. Update on normal tension glaucoma

    Directory of Open Access Journals (Sweden)

    Jyotiranjan Mallick

    2016-01-01

    Full Text Available Normal tension glaucoma (NTG is labelled when typical glaucomatous disc changes, visual field defects and open anterior chamber angles are associated with intraocular pressure (IOP constantly below 21 mmHg. Chronic low vascular perfusion, Raynaud's phenomenon, migraine, nocturnal systemic hypotension and over-treated systemic hypertension are the main causes of normal tension glaucoma. Goldmann applanation tonometry, gonioscopy, slit lamp biomicroscopy, optical coherence tomography and visual field analysis are the main tools of investigation for the diagnosis of NTG. Management follows the same principles of treatment for other chronic glaucomas: To reduce IOP by a substantial amount, sufficient to prevent disabling visual loss. Treatment is generally aimed to lower IOP by 30% from pre-existing levels to 12-14 mmHg. Betaxolol, brimonidine, prostaglandin analogues, trabeculectomy (in refractory cases, systemic calcium channel blockers (such as nifedipine and 24-hour monitoring of blood pressure are considered in the management of NTG. The present review summarises risk factors, causes, pathogenesis, diagnosis and management of NTG.

  4. Length-tension relationships of small arteries, veins, and lymphatics from the rat mesenteric microcirculation.

    Science.gov (United States)

    Zhang, Rong-Zhen; Gashev, Anatoliy A; Zawieja, David C; Davis, Michael J

    2007-04-01

    The passive and active length-tension relationships of isolated rat mesenteric lymphatics ( approximately 150 microm ID), and adjacent small arteries ( approximately 240 microm) and veins ( approximately 275 microm) were compared under isometric conditions using a wire myograph. About 60% of the lymphatic vessels developed spontaneous contractions in physiological saline solution at nominal preload. To maximally activate smooth muscle, 145 mM K(+) + 5 x 10(-5) M norepinephrine was used for arteries, and 145 mM K(+) + 1 x 10(-6) M substance P was used for lymphatics and veins. In response, arteries exhibited monotonic force development to a plateau level, whereas lymphatics and veins showed biphasic force development, consisting of a transient force peak followed by partial relaxation to a plateau over approximately 5 min. The passive and the active length-tension curves were similar in shape among all three vessels. However, the maximal active tension of arteries (3.4 +/- 0.42 mN/mm) was significantly greater than peak active tension (0.59 +/- 0.04 mN/mm) or plateau tension (0.20 +/- 0.04 mN/mm) in small veins and greater than peak active tension (0.34 +/- 0.02 mN/mm) or plateau tension (0.21 +/- 0.02 mN/mm) in lymphatics. Maximal active medial wall stress was similar between lymphatics and veins but was approximately fivefold higher in small arteries. For lymphatics, the pressure calculated from the optimal preload was significantly higher than that found previously in isobaric studies of isolated lymphatics, suggesting the capacity to operate at higher than normal pressures for increased responsiveness. Our results represent the first mechanical comparisons of arterial, venous, and lymphatic vessels in the same vasculature.

  5. 30 CFR 57.12047 - Guy wires.

    Science.gov (United States)

    2010-07-01

    ... Underground § 57.12047 Guy wires. Guy wires of poles supporting high-voltage transmission lines shall meet the... “Safety Rules for the Installation and Maintenance of Electric Supply and Communication Lines”...

  6. Anode wire aging tests with selected gases

    Energy Technology Data Exchange (ETDEWEB)

    Kadyk, J.; Wise, J.; Hess, D.; Williams, M. (Lawrence Berkeley Lab., CA (United States))

    1990-04-01

    As a continuation of earlier wire aging investigations, additional candidates for wire chamber gas and wire have been tested. These include the gases: argon/ethane, HRS gas, dimethyl ether, carbon dioxide/ethane, and carbon tetrafluoride/isobutane. Wires used were: gold- plated tungsten, Stablohm, Nicotin, and Stainless Steel. Measurements were made of the effects upon wire aging of impurities from plumbing materials or contamination from various types of oil. Attempts were made to induce wire aging by adding measured amounts of oxygen and halogen (methyl chloride) with negative results. In this paper, the possible role of electronegativity in the wire aging process is discussed, and measurements of electronegativity are made with several single carbon Freons, using both an electron capture detector and a wire chamber operating with dimethyl ether.

  7. Evaluation of high temperature stranded hookup wire

    Science.gov (United States)

    Donnelly, J. H.; Moore, H. J., Jr.

    1967-01-01

    Tests are performed on wire and insulation materials to determine selection for electronic space assemblies. Wire characteristics of tensile strength, flexibility, conductivity, and general workability are tested. Knowledge of the advantages and limitations of these materials should prevent overspecification.

  8. TCP/IP Over SpaceWire

    Science.gov (United States)

    Mills, S.; Parkes, S.

    The SpaceWire standard defines a network designed for handling payload data and control information onboard a spacecraft. Among the goals of SpaceWire are re-usability and reliability. The use of network protocols on top of SpaceWire is expected to enhance the already rich re-usability and reliability characteristics of SpaceWire. The Space Systems Research Group at the University of Dundee have developed software to allow data to be sent over SpaceWire using standard network protocols such as TCP/IP, as part of a program of work looking at network protocols for SpaceWire. This paper describes network protocols and their relationship to SpaceWire, introduces software written to allow network protocols to be layered on to SpaceWire, describes the research behind the development of this software, and gives results of some tests and observations made using the software.

  9. Patella fracture fixation with suture and wire: you reap what you sew.

    Science.gov (United States)

    Egol, Kenneth; Howard, Daniel; Monroy, Alexa; Crespo, Alexander; Tejwani, Nirmal; Davidovitch, Roy

    2014-01-01

    Operative fixation of displaced inferior pole patella fractures has now become the standard of care. This study aims to quantify clinical, radiographic and functional outcomes, as well as identify complications in a cohort of patients treated with non-absorbable braided suture fixation for inferior pole patellar fractures. These patients were then compared to a control group of patients treated for mid-pole fractures with K-wires or cannulated screws with tension band wiring. In this IRB approved study, we identified a cohort of patients who were diagnosed and treated surgically for a displaced patella fracture. Demographic, injury, and surgical information were recorded. All patients were treated with a standard surgical technique utilizing non-absorbable braided suture woven through the patellar tendon and placed through drill holes to achieve reduction and fracture fixation. All patients were treated with a similar post-operative protocol and followed up at standard intervals. Data were collected concurrently at follow up visits. For purpose of comparison, we identified a control cohort with middle third patella fractures treated with either k-wires or cannulated screws and tension band technique. Patients were followed by the treating surgeon at regular follow-up intervals. Outcomes included self-reported function and knee range of motion compared to the uninjured side. Forty-nine patients with 49 patella fractures identified retrospectively were treated over 9 years. This cohort consisted of 31 females (63.3%) and 18 males (36.7%) with an average age of 57.1 years (range 26-88 years). Patients had an average BMI of 26.48 (range 19-44.08). Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with mid-pole fractures underwent tension band fixation (K-wire or cannulated screws with tension band). In the suture cohort, one fracture failed open repair (7.6%), which was revised again with sutures and progressed to union. Of the 36

  10. Novel Wiring Technologies for Aerospace Applications

    Science.gov (United States)

    Gibson, Tracy L.; Parrish, Lewis M.

    2014-01-01

    Because wire failure in aerospace vehicles could be catastrophic, smart wiring capabilities have been critical for NASA. Through the years, researchers at Kennedy Space Center (KSC) have developed technologies, expertise, and research facilities to meet this need. In addition to aerospace applications, NASA has applied its knowledge of smart wiring, including self-healing materials, to serve the aviation industry. This webinar will discuss the development efforts of several wiring technologies at KSC and provide insight into both current and future research objectives.

  11. Further Studies Of Hot-Wire Anemometry

    Science.gov (United States)

    Mckenzie, Robert; Logan, Pamela; Bershader, Daniel

    1990-01-01

    Report discusses factors affecting readings of hot-wire anemometer in turbulent supersonic boundary layer. Represents extension of work described in "Hot-Wire Anemometry Versus Laser-Induced Fluorescence" (ARC-11802). Presents theoretical analysis of responses of hot-wire probe to changes in flow; also compares measurements by hot-wire probe with measurements of same flows by laser-induced fluorescence (LIF).

  12. Different mechanical properties in Seldinger guide wires

    Directory of Open Access Journals (Sweden)

    Wolfram Schummer

    2015-01-01

    Full Text Available Background and Aims: Most central venous catheters are placed using Seldinger guide wires. EN ISO 11070 is the guideline for testing guide wire flexing performance and tensile strength, and we can safely assume that guide wires in use meet these requirements. Unfortunately, EN ISO 11070 guidelines do not reflect the clinical requirements and we continue to see mechanical failures and their associated complications. Material and Methods: This in vitro study was performed in an accredited laboratory. With regard to flexing, we: (1 Established the minimum flexing performance needed to meet clinical requirements, (2 developed flexing performance tests which mimic clinical requirement, and (3 evaluated the mechanical properties of various guide wires relative to these requirements. With regard to tensile strength, we used the testing method prescribed in ISO 11070, but did not end the test at 5 Newton (N. We continued until the guide wire was damaged, or we reached maximum tractive force. We then did a wire-to-wire comparison. We examined two basic wire constructions, monofil and core and coil. Results: Tensile strength: All wires tested, except one, met EN ISO 11070 requirements for 5 N tensile strength. The mean of the wire types tested ranged from 15.06 N to 257.76 N. Flexing performance: None of the wires kinked. The monofil had no evidence of bending. Two core/coil wires displayed minor bending (angle 1.5°. All other wires displayed bending angles between 22.5° and 43.0°. Conclusion: We recommend that: (1 Clinicians use guide wires with high-end mechanical properties, (2 EN ISO 11070 incorporate our flexing test into their testing method, raise the flexing requirement to kink-proof, (3 and raise the tensile strength requirement to a minimum of 30 N, and (3 all manufacturers and suppliers be required to display mechanical properties of all guide wire, and guide wire kits sold.

  13. One century of Kirschner wires and Kirschner wire insertion techniques : A historical review

    NARCIS (Netherlands)

    Franssen, Bas B. G. M.; Schuurman, Arnold H.; Van der Molen, Aebele Mink; Kon, Moshe

    2010-01-01

    A century ago, in 1909, Martin Kirschner (1879-942) introduced a smooth pin, presently known as the Kirschner wire (K-wire). The K-wire was initiallly used for skeletal traction and is now currently used for many different goals. The development of the K-wire and its insertion devices were mainly in

  14. Surface tension profiles in vertical soap films

    CERN Document Server

    Adami, N

    2013-01-01

    Surface tension profiles in vertical soap films are experimentally investigated. Measurements are performed introducing deformable elastic objets in the films. The shape adopted by those objects set in the film can be related to the surface tension value at a given vertical position by numerical solving of adapted elasticity equations. We show that the observed dependency of the surface tension versus the vertical position in the soap film can be reproduced by simple modeling taking into account film thickness measurements.

  15. On Surface Tension for Compact Stars

    Indian Academy of Sciences (India)

    R. Sharma; S. D. Maharaj

    2007-06-01

    In an earlier analysis it was demonstrated that general relativity gives higher values of surface tension in strange stars with quark matter than neutron stars. We generate the modified Tolman–Oppenheimer–Volkoff equation to incorporate anisotropic matter and use this to show that pressure anisotropy provides for a wide range of behaviour in the surface tension than is the case with isotropic pressures. In particular, it is possible that anisotropy drastically decreases the value of the surface tension.

  16. Getting "Wired" for McLuhan's Cyberculture.

    Science.gov (United States)

    McMurdo, George

    1995-01-01

    Examines the introduction of the computing magazine, "Wired", into the United Kingdom's (UK) market. Presents conversations with the founder and editorial staff of the UK edition, and discusses the accessibility of "Wired" via the World Wide Web. Describes 10 articles from United States "Wired" back-issues and…

  17. Generalized additional boundary conditions for wire media

    Energy Technology Data Exchange (ETDEWEB)

    Maslovski, Stanislav I; Morgado, Tiago A; Silveirinha, Mario G [Departamento de Engenharia Electrotecnica, Instituto de Telecomunicacoes, Universidade de Coimbra, Polo II, 3030-290 Coimbra (Portugal); Kaipa, Chandra S R; Yakovlev, Alexander B, E-mail: stas@co.it.p [Department of Electrical Engineering, University of Mississippi, University, MS 38677-1848 (United States)

    2010-11-15

    We generalize additional boundary conditions (ABCs) for wire media by including arbitrary wire junctions with impedance loading. Special attention is given to the conditions at the interface of two uniaxial wire media with metallic patches at the junction. The derived ABCs are validated against full-wave numerical simulations.

  18. 75 FR 4584 - Wire Decking From China

    Science.gov (United States)

    2010-01-28

    ... COMMISSION Wire Decking From China AGENCY: United States International Trade Commission. ACTION: Scheduling... retarded, by reason of subsidized and less-than-fair-value imports from China of wire decking, provided for..., producers, or exporters in China of wire decking, and that such ] products are being sold in the...

  19. 49 CFR 393.28 - Wiring systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Wiring systems. 393.28 Section 393.28 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.28 Wiring systems...

  20. HILBERTIAN APPROACH FOR UNIVARIATE SPLINE WITH TENSION

    Institute of Scientific and Technical Information of China (English)

    A.Bouhamidi

    2001-01-01

    In this work,a new approach is proposed for constructing splines with tension.The basic idea is in the use of distributions theory,which allows us to define suitable Hilbert spaces in which the tension spline minimizes some energy functional.Classical orthogonal conditions and characterizations of the spline in terms of a fundamental solution of a differential operator are provided.An explicit representation of the tension spline is given.The tension spline can be computed by solving a linear system.Some numerical examples are given to illustrate this approach.

  1. Surface Tension Calculation of Undercooled Alloys

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Based on the Butler equation and extrapolated thermodynamic data of undercooled alloys from those of liquid stable alloys, a method for surface tension calculation of undercooled alloys is proposed. The surface tensions of liquid stable and undercooled Ni-Cu (xNi=0.42) and Ni-Fe (xNi=0.3 and 0.7) alloys are calculated using STCBE (Surface Tension Calculation based on Butler Equation) program. The agreement between calculated values and experimental data is good enough, and the temperature dependence of the surface tension can be reasonable down to 150-200 K under the liquid temperature of the alloys.

  2. Enhanced Electrical Conductivity in Extruded Single-Wall Carbon Nanotube Wires from Modified Coagulation Parameters and Mechanical Processing.

    Science.gov (United States)

    Bucossi, Andrew R; Cress, Cory D; Schauerman, Christopher M; Rossi, Jamie E; Puchades, Ivan; Landi, Brian J

    2015-12-16

    Single-wall carbon nanotubes (SWCNTs) synthesized via laser vaporization have been dispersed using chlorosulfonic acid (CSA) and extruded under varying coagulation conditions to fabricate multifunctional wires. The use of high purity SWCNT material based upon established purification methods yields wires with highly aligned nanoscale morphology and an over 4× improvement in electrical conductivity over as-produced SWCNT material. A series of eight liquids have been evaluated for use as a coagulant bath, and each coagulant yielded unique wire morphology based on its interaction with the SWCNT-CSA dispersion. In particular, dimethylacetamide as a coagulant bath is shown to fabricate highly uniform SWCNT wires, and acetone coagulant baths result in the highest specific conductivity and tensile strength. A 2× improvement in specific conductivity has been measured for SWCNT wires following tensioning induced both during extrusion via increased coagulant bath depth and during solvent evaporation via mechanical strain, over that of as-extruded wires from shallower coagulant baths. Overall, combination of the optimized coagulation parameters has yielded acid-doped wires with the highest reported room temperature electrical conductivities to date of 4.1-5.0 MS/m and tensile strengths of 210-250 MPa. Such improvements in bulk electrical conductivity can impact the adoption of metal-free, multifunctional SWCNT materials for advanced cabling architectures.

  3. [Tension pneumomediastinum and tension pneumothorax following tracheal perforation during cardiopulmonary resuscitation].

    Science.gov (United States)

    Buschmann, C T; Tsokos, M; Kurz, S D; Kleber, C

    2015-07-01

    Tension pneumothorax can occur at any time during cardiopulmonary resuscitation (CPR) with external cardiac massage and invasive ventilation either from primary or iatrogenic rib fractures with concomitant pleural or parenchymal injury. Airway injury can also cause tension pneumothorax during CPR. This article presents the case of a 41-year-old woman who suffered cardiopulmonary arrest after undergoing elective mandibular surgery. During CPR the upper airway could not be secured by orotracheal intubation due to massive craniofacial soft tissue swelling. A surgical airway was established with obviously unrecognized iatrogenic tracheal perforation and subsequent development of tension pneumomediastinum and tension pneumothorax during ventilation. Neither the tension pneumomediastinum nor the tension pneumothorax were decompressed and accordingly resuscitation efforts remained unsuccessful. This case illustrates the need for a structured approach to resuscitate patients with ventilation problems regarding decompression of tension pneumomediastinum and/or tension pneumothorax during CPR.

  4. The Plastic Tension Field Method

    DEFF Research Database (Denmark)

    Hansen, Thomas

    2005-01-01

    . The emphasis is attached to the presentation of a design method based on the diagonal tension field theory. Also, how to determine the load-carrying capacity of a given steel plate girder with transverse web stiffeners, is briefly presented. The load-carrying capacity may be predicted by applying both...... method. The method is based on the theory of plasticity and is analogous to the so-called diagonal compression field method developed for reinforced concrete beams with transverse stirrups, which is adopted in the common European concrete code (Eurocode 2). Many other theories have been developed......, but the method presented differs from these theories by incorporating the strength of the transverse stiffeners and by the assumption that the tensile bands may pass the transverse stiffeners, which often is observed in tests. Other methods have only dealt with a single web field between two stiffeners...

  5. A Large, Free-Standing Wire Grid for Microwave Variable-delay Polarization Modulation

    Science.gov (United States)

    Voellmer, George

    2008-01-01

    One technique for mapping the polarization signature of the cosmic microwave background uses large, polarizing grids in reflection. We present the system requirements, the fabrication, assembly, and alignment procedures, and the test results for the polarizing grid component of a 50 cm clear aperture, Variable-delay Polarization Modulator (VPM). This grid is being built and tested at the Goddard Space Flight Center as part of the Polarimeter for Observing Inflationary Cosmology at the Reionization Epoch (POINCARE). VPMs modulate the polarized component of a radiation source by splitting the incoming beam into two orthogonal polarization components using a free-standing wire grid. The path length difference between these components is varied with a translating mirror, and then they are recombined. This precision instrumentation technique can be used to encode and demodulate the cosmic microwave background's polarization signature. For the demonstration instrument, 64 micrometer diameter tungsten wires are being assembled into a 200 pm pitch, free-standing wire grid with a 50 cm clear aperture, and an expected overall flatness better than 30 micrometers. A rectangular, aluminum stretching frame holds the wires with sufficient tension to achieve a minimum resonant frequency of 185 Hz, allowing VPM mirror translation frequencies of several Hz. A lightly loaded, flattening ring with a 50 cm inside diameter rests against the wires and brings them into accurate planarity.

  6. Energy Deposition in a Septum Wire

    CERN Document Server

    Ferioli, G; Knaus, P; Koopman, J; CERN. Geneva. SPS and LHC Division

    2001-01-01

    The present note describes a machine development (MD) aimed to confirm experimentally the need for protection of the extraction wire septum ZS in SPS long straight section LSS6 during LHC operation. Single wires identical to the ones mounted on the extraction septum were fixed on a fast wire scanner and put into the beam path. The beam heated the wire until it broke after a measured number of turns. The maximum single shot intensity the septum wires could withstand was thus calculated and compared with simulation results.

  7. Directional growth of polypyrrole and polythiophene wires

    Science.gov (United States)

    Thapa, Prem S.; Yu, Deok Jin; Wicksted, James P.; Hadwiger, Jeffrey A.; Barisci, Joseph N.; Baughman, Ray H.; Flanders, Bret N.

    2009-01-01

    This work establishes an innovative electrochemical approach to the template-free growth of conducting polypyrrole and polythiophene wires along predictable interelectrode paths up to 30 μm in length. These wires have knobby structures with diameters as small as 98 nm. The conductivity of the polypyrrole wires is 0.5±0.3 S cm-1; that of the polythiophene wires is 7.6±0.8 S cm-1. Controlling the growth path enables fabrication of electrode-wire-target assemblies where the target is a biological cell in the interelectrode gap. Such assemblies are of potential use in cell stimulation studies.

  8. Clinical bending of nickel titanium wires

    Directory of Open Access Journals (Sweden)

    Stephen Chain

    2015-01-01

    Full Text Available Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our inventory but also customized the wire according to the treatment.

  9. Impact of Sterilisation and Strain Hardening in Drawing Process on Resistance to Electrochemical Corrosion of Wires Intended in Cardiology

    Directory of Open Access Journals (Sweden)

    Przondziono J.

    2016-03-01

    Full Text Available The study presents results of tests of impact of work hardening in cold drawing process, surface treatment and sterilisation on resistance to electrochemical corrosion of wires made of stainless steel X2CrNiMo 17-12-2 intended for cardiology. Potentiodynamic tests were performed on the ground of registered anodic polarisation curves in artificial plasma solution. Static uniaxial tension test made the ground for determination of strength characteristics of wires and the flow curve. Functions presenting the change of polarisation resistance according to strain applied in drawing process were selected.

  10. Composite wire plasma formation and evolution

    Energy Technology Data Exchange (ETDEWEB)

    Spielman, R.B.

    2000-01-01

    The detailed understanding of the formation and evolution of plasma from rapidly heated metallic wires is a long-standing challenge in the field of plasma physics and in exploding wire engineering. This physical process is made even more complicated if the wire material is composed of a number of individual layers. The authors have successfully developed both optical and x-ray backlighting diagnostics. In particular, the x-ray backlighting technique has demonstrated the capability for quantitative determination of the plasma density over a wide range of densities. This diagnostic capability shows that the process of plasma formation is composed of two separate phases: first, current is passed through a cold wire and the wire is heated ohmically, and, second, the heated wire evolves gases that break down and forms a low-density plasma surrounding the wire.

  11. Microstructure and mechanical behavior of annealed MP35N alloy wire

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, M.J.N.V. [School of Engineering, Brown University, Providence, RI 02912 (United States); Department of Metallurgical Engineering and Materials Science, Indian Institute of Technology Bombay, Powai, Mumbai 400076 (India); Reiterer, M.W. [Medtronic, PLC, USA, Science and Technology, Minneapolis, MN 55432 (United States); Kumar, K.S., E-mail: Sharvan_Kumar@brown.edu [School of Engineering, Brown University, Providence, RI 02912 (United States)

    2015-06-11

    In a previous paper, the microstructure, monotonic, and cyclic response of as-drawn ~100 μm diameter MP35N low-Ti alloy wire were presented and discussed. In this sequel paper, the effects of annealing the same cold-drawn wire on microstructure and mechanical properties are examined. Specifically, segments of the wire were annealed for 1 h at 973 K, 1023 K, 1073 K, 1123 K and 1173 K in a vacuum furnace. The resulting microstructure was characterized by SEM, EBSD and TEM and compared to the as-drawn microstructure. In-situ heating in the TEM of MP35N ribbon in a similarly cold worked condition enabled corroboration of microstructure evolution during annealing. Annealed wires were tested monotonically and cyclically in uniaxial tension at room temperature, the latter using a stress ratio (R) of 0.3. In addition, the annealed wires were tested cyclically at R=−1 using the rotating beam bending fatigue test. Post-deformation structures and fracture surfaces were characterized using TEM and SEM respectively. Annealing the cold drawn wire results in recrystallization and grain growth; the extent is dependent on the annealing temperature. Deformation twin boundaries in the as-drawn structure illustrate faceted bulging and eventually complete elimination, the microstructure evolving into fine equiaxed grains containing coarser annealing twins with no significant change in texture. Yield strength decreases rapidly with recrystallization to almost half the value of the as-drawn condition, but is accompanied by an increase in modulus (by ~25%) and tensile elongation reaching ~30%. Cyclic response by the way of S–N curves is not enhanced by annealing on an absolute stress scale (due to the loss in yield strength) although the annealed wires are cyclically superior when the stress data are normalized by yield stress.

  12. Traumatic tension pneumocephalus: Two case reports

    Directory of Open Access Journals (Sweden)

    Abubaker Al-Aieb

    2017-01-01

    Conclusions: These are two rare cases with posttraumatic tension pneumocephalus treated conservatively with a favorable outcome. Early diagnosis of tension pneumocephalus is a crucial step to facilitate early recovery; however, the associated injuries need attention as they could influence the hospital course.

  13. Tension and robustness in multitasking cellular networks.

    Directory of Open Access Journals (Sweden)

    Jeffrey V Wong

    Full Text Available Cellular networks multitask by exhibiting distinct, context-dependent dynamics. However, network states (parameters that generate a particular dynamic are often sub-optimal for others, defining a source of "tension" between them. Though multitasking is pervasive, it is not clear where tension arises, what consequences it has, and how it is resolved. We developed a generic computational framework to examine the source and consequences of tension between pairs of dynamics exhibited by the well-studied RB-E2F switch regulating cell cycle entry. We found that tension arose from task-dependent shifts in parameters associated with network modules. Although parameter sets common to distinct dynamics did exist, tension reduced both their accessibility and resilience to perturbation, indicating a trade-off between "one-size-fits-all" solutions and robustness. With high tension, robustness can be preserved by dynamic shifting of modules, enabling the network to toggle between tasks, and by increasing network complexity, in this case by gene duplication. We propose that tension is a general constraint on the architecture and operation of multitasking biological networks. To this end, our work provides a framework to quantify the extent of tension between any network dynamics and how it affects network robustness. Such analysis would suggest new ways to interfere with network elements to elucidate the design principles of cellular networks.

  14. Normal-tension glaucoma (Low-tension glaucoma

    Directory of Open Access Journals (Sweden)

    Anderson Douglas

    2011-12-01

    Full Text Available Glaucoma is now considered an abnormal physiology in the optic nerve head that interacts with the level of intraocular pressure (IOP, with the degree and rate of damage depending on the IOP and presumably the degree of abnormal physiology. Diagnosis of normal-tension glaucoma (NTG, defined as glaucoma without a clearly abnormal IOP, depends on recognizing symptoms and signs associated with optic nerve vulnerability, in addition to absence of other explanations for disc abnormality and visual field loss. Among the findings are a halo or crescent of absence of retinal pigment epithelium around the disc, bilateral pre-chiasmal visual field defects, splinter hemorrhages at the disc margin, vascular dysregulation (low blood pressure, cold hands and feet, migraine headache with aura, and the like, or a family history of glaucoma. Possibly relevant, is a history of hemodynamic crisis, arterial obstructive disease, or sleep apnea. Neurological evaluation with imaging is needed only for atypical cases or ones that progress unexpectedly. Management follows the same principle of other chronic glaucomas, to lower the IOP by a substantial amount, enough to prevent disabling visual loss. However, many NTG cases are non-progressive. Therefore, it may often be wisein mild cases to determine whether the case is progressive and the rate of progression before deciding on how aggressivene to be with therapy. Efforts at neuroprotection and improvement in blood flow have not yet been shown effective.

  15. Compound Tension Control of an Optical-Fiber Coil System: A Cyber-Physical System View

    Directory of Open Access Journals (Sweden)

    Zhang Peng

    2014-03-01

    Full Text Available The full-automatic optical-fiber coil winding equipment is a complex electromechanical system which contains signal acquisition, data processing, communications, and motor control. In the complex electromechanical system, the subsystems rely on wired or wireless network technology to complete the real-time perception, coordinate, accurate, and dynamitic control, and information exchange services. The paper points to the full-automatic optical-fiber coil winding equipment with the characteristics of cyber-physical system to research its numerical design. We present a novel compound tension control system based on the experimental platform dSPACE to achieve semiphysical simulation of compound tension control system and examine the functions of control system.

  16. Magnetic Tension of Sunspot Fine Structures

    CERN Document Server

    Venkatakrishnan, P

    2010-01-01

    The equilibrium structure of sunspots depends critically on its magnetic topology and is dominated by magnetic forces. Tension force is one component of the Lorentz force which balances the gradient of magnetic pressure in force-free configurations. We employ the tension term of the Lorentz force to clarify the structure of sunspot features like penumbral filaments, umbral light bridges and outer penumbral fine structures. We compute vertical component of tension term of Lorentz force over two active regions namely NOAA AR 10933 and NOAA AR 10930 observed on 05 January 2007 and 12 December 2006 respectively. The former is a simple while latter is a complex active region with highly sheared polarity inversion line (PIL). The vector magnetograms used are obtained from Hinode(SOT/SP). We find an inhomogeneous distribution of tension with both positive and negative signs in various features of the sunspots. The existence of positive tension at locations of lower field strength and higher inclination is compatible...

  17. Subacute Tension Hemopneumothorax with Novel Electrocardiogram Findings

    Directory of Open Access Journals (Sweden)

    Saks, Mark A

    2010-02-01

    Full Text Available This case report describes a patient with a subacute right-sided tension hemopneumothorax following an occult stab. The patient’s electrocardiogram (ECG, performed as part of a standardized triage process, demonstrated significant abnormalities that misguided initial resuscitation, but resolved following evacuation of the tension hemopneumothorax. Tension pneumothorax is typically regarded as an immediately life-threatening condition that requires emergent management with needle or tube thoracostomy. However, we believe that subacute tension pneumothorax may be a rarely observed clinical phenomenon and may lead to unique ECG findings. We believe that the ECG changes we observed provided an early clue to the eventual diagnosis of a subacute tension pneumothorax and have not been previously described in this setting. . [West J Emerg Med. 2010; 11(1:86-89].

  18. FORMULAS OF TENSION OF CONTINUOUS ROLLING PROCESS

    Institute of Scientific and Technical Information of China (English)

    J.Z. Zhang; X.P. Zhang

    2007-01-01

    The development of computer controlled continuous rolling process calls for a mathematicalexpression that can express the inequality condition of "constant flow". Tension is the link of thecontinuous rolling process. From the condition of dynamic equilibrium, a differential equation oftension is given out. On the basis of the physical rules established from the industrial practice andexperimental studies, the law of volume constancy, the linear relation of forward slip and tension,the state equation of continuous rolling, the formula of dynamic tension, and the formula of statictension have been obtained. These formulae reflect the functional relations between tensions,thickness, roll velocity, and time in the continuous rolling process. It is implied that the continuousrolling process is a gradually steady, controllable, and measurable dynamic system. An assumptionof predicting the thickness of a steel plate using these tension formulae is also put forward.

  19. Preparation of uncladded YBCO wires

    Science.gov (United States)

    Grader, G.; Cadoche, L.; Shter, G.

    1993-04-01

    Wires of YBCO, 1-5 mm in diameter, have been obtained by extrusion of an oxalate derived powder mixed with polyvinyl butyral (PVB) and two phthalate plasticizers. The densification and transport properties of the wires were investigated at various organic loading conditions. For YBCO powder prepared by oxalate coprecipitation and calcined at 930°C, the maximal strength, relative density and Jc were 20MPa, 92% and 400A/cm 2, respectively. Results show that after a 4-hour sintering at 955°C the tensile strength, density, and Jc are all maximized at a binder content of 3-4 wt.%. The loading of up to 10 wt.% dibutyl phthalate (DBP) plasticizer (in the binder) has little effect on the properties. Beyond this loading a drastic drop in Jc is observed. The densification was very poor for sinterings below 950°C, which was reflected by a lower critical current.

  20. Thermoprocessing and wire drawing behaviour of ultra high strength steel wires

    Directory of Open Access Journals (Sweden)

    S.S. Bargujer

    2016-09-01

    Full Text Available The thermo-processing of piano wire rods is carried out in the lead bath. This experimentation is carried out under industrial conditions. The investigation is done to examine the effect of austenitic time, lead bath time and wire diameter on mechanical properties of lead patented wire. The Taguchi technique is adopted for optimization of thermo-processing of hypereutectoid steel wires. The lead patented wire of diameter 7.00 mm is cold drawn in a sequence of conical converging dies. The best pass schedule of lead patented piano wire is obtained by optimizing the ultimate tensile strength and torsion strength of cold drawn wire. The characterization of wire drawing behaviour of lead patented wires is carried out using optical microscopy, scanned electron microscopy and X-ray diffraction analysis techniques.

  1. SpaceWire Satellite Usage

    Science.gov (United States)

    2013-03-01

    Figure 1. SpaceWire Topologies 309 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of...RS422 Hosted Payload data interface Joint  Architeccture  Standards Sandia,  LANL control interface; backplane sRIO, PCIe Common standards for joint

  2. Concept of porous wire anemometer

    Energy Technology Data Exchange (ETDEWEB)

    Afgan, N.H.; Pereira, J.C. [Inst. Superior Tecnico, Lisbon (Portugal); Leontiev, A.I.; Puzach, S.V. [Moscow Technical Univ. (Russian Federation)

    1997-05-01

    The paper presents a new scheme of the anemometer sensing element for the gas mean and fluctuation velocity measurement. The sensing element is a porous tube with gas suction through porous tube wall. The outside surface of the porous tube is at the gas temperature. The analysis, based on the heat balance at steady and unsteady state is performed in order to define the sensitivity and time constant of the porous sensing element. Two cases are considered, namely, the constant current and constant temperature anemometer. Comparison is made with the solid wire anemometer and shown that the proposed porous sensing element can have sensitivity four times higher than the standard hot wire anemometer with the same geometrical dimensions. With the respective selection of the physical properties of the sensing element, it could be possible to obtain higher frequency range of the measurement. Particular attention is devoted to the low gas velocity measurement. It is recognized that the minimum gas velocity to be measured with the solid hot wire anemometer is determined by the local heat transfer coefficient. For the low gas velocity, it was proved that the minimum is around .20 cm/sec. The proposed concept of the sensing element can be used for the very low velocity measurement due to the higher sensitivity obtained by the porous sensing element.

  3. High compressive pre-strains reduce the bending fatigue life of nitinol wire.

    Science.gov (United States)

    Gupta, Shikha; Pelton, Alan R; Weaver, Jason D; Gong, Xiao-Yan; Nagaraja, Srinidhi

    2015-04-01

    Prior to implantation, Nitinol-based transcatheter endovascular devices are subject to a complex thermo-mechanical pre-strain associated with constraint onto a delivery catheter, device sterilization, and final deployment. Though such large thermo-mechanical excursions are known to impact the microstructural and mechanical properties of Nitinol, their effect on fatigue properties is still not well understood. The present study investigated the effects of large thermo-mechanical pre-strains on the fatigue of pseudoelastic Nitinol wire using fully reversed rotary bend fatigue (RBF) experiments. Electropolished Nitinol wires were subjected to a 0%, 8% or 10% bending pre-strain and RBF testing at 0.3-1.5% strain amplitudes for up to 10(8) cycles. The imposition of 8% or 10% bending pre-strain resulted in residual set in the wire. Large pre-strains also significantly reduced the fatigue life of Nitinol wires below 0.8% strain amplitude. While 0% and 8% pre-strain wires exhibited distinct low-cycle and high-cycle fatigue regions, reaching run out at 10(8) cycles at 0.6% and 0.4% strain amplitude, respectively, 10% pre-strain wires continued to fracture at less than 10(5) cycles, even at 0.3% strain amplitude. Furthermore, over 70% fatigue cracks were found to initiate on the compressive pre-strain surface in pre-strained wires. In light of the texture-dependent tension-compression asymmetry in Nitinol, this reduction in fatigue life and preferential crack initiation in pre-strained wires is thought to be attributed to compressive pre-strain-induced plasticity and tensile residual stresses as well as the formation of martensite variants. Despite differences in fatigue life, SEM revealed that the size, shape and morphology of the fatigue fracture surfaces were comparable across the pre-strain levels. Further, the mechanisms underlying fatigue were found to be similar; despite large differences in cycles to failure across strain amplitudes and pre-strain levels, cracks

  4. "Cut wires grating – single longitudinal wire" planar metastructure to achieve microwave magnetic resonance in a single wire

    Directory of Open Access Journals (Sweden)

    G. Kraftmakher

    2012-09-01

    Full Text Available Here we present metastructures containing cut-wire grating and a single longitudinal cut-wire orthogonal to grating’s wires. Experimental investigations at microwaves show these structures can provide strong magnetic resonant response of a single nonmagnetic cut-wire in dependence on configuration and sizes in the case when metastructures are oriented along the direction of wave propagation and cut-wires of grating are parallel to the electric field of a plane electromagnetic wave. It is suggested a concept of magnetic response based on antiparallel resonant currents excited by magnetic field of surface polaritons in many spatial LC-circuits created from cut-wire pairs of a grating and section of longitudinal cut-wire. Three separately observed resonant effects connected with grating, LC-circuits and with longitudinal cut-wire have been identified applying measurements in waveguides, cutoff waveguides and free space. To tune and mark resonance split cut-wires are loaded with varactor diodes.

  5. EFFECTS OF WIRE LAG IN WIRE ELECTRICAL DISCHARGE MACHINING (WEDM

    Directory of Open Access Journals (Sweden)

    S. K. SINHA

    2010-11-01

    Full Text Available WEDM is very useful wherever complex geometry with tight tolerances needs to be generated on hard materials. In view of modern and sophisticated technology readily available these days, the expectation of accuracy in WEDM is ever-increasing, and therefore, techniques for the improvement in WEDM must be developed. The main cause of inaccuracy is wire-lag, the cause and effect of which is described in the present work, along with a technique to obviate the problem in straight cutting. In a subsequent paper, a software approach (since the problem gets too complicated for improvement of accuracy in contour cutting is described.

  6. The surface tension of liquid gallium

    Science.gov (United States)

    Hardy, S. C.

    1985-01-01

    The surface tension of liquid gallium has been measured using the sessile drop technique in an Auger spectrometer. The experimental method is described. The surface tension in mJ/sq m is found to decrease linearly with increasing temperature and may be represented as 708-0.66(T-29.8), where T is the temperature in centigrade. This result is of interest because gallium has been suggested as a model fluid for Marangoni flow experiments. In addition, the surface tension is of technological significance in the processing of compound semiconductors involving gallium.

  7. Surface tension profiles in vertical soap films

    Science.gov (United States)

    Adami, N.; Caps, H.

    2015-01-01

    Surface tension profiles in vertical soap films are experimentally investigated. Measurements are performed by introducing deformable elastic objets in the films. The shape adopted by those objects once set in the film is related to the surface tension value at a given vertical position by numerically solving the adapted elasticity equations. We show that the observed dependency of the surface tension versus the vertical position is predicted by simple modeling that takes into account the mechanical equilibrium of the films coupled to previous thickness measurements.

  8. Computer-aided design of tension structures

    OpenAIRE

    Ong, C.F.

    1992-01-01

    This thesis consists of three parts. Part I (chapters 1-4) gives a review and description of the basis for the numerical modelling of tension structures. The discussion in Part I leads to the conclusion of a need for an interactive design procedure for tension structures which is the subject under consideration in Part II (chapters 5-7). In the design of tension structures, an area which requires special attention is the dynamic response often initiated by the action of a natural wind. In Par...

  9. Electromagnetic Behaviour of Metallic Wire Structures

    CERN Document Server

    Chui, S T

    2013-01-01

    Despite the recent development and interest in the photonics of metallic wire structures, the relatively simple concepts and physics often remain obscured or poorly explained to those who do not specialize in the field. Electromagnetic Behaviour of Metallic Wire Structures provides a clear and coherent guide to understanding these phenomena without excessive numerical calculations.   Including both background material and detailed derivations of the various different formulae applied, Electromagnetic Behaviour of Metallic Wire Structures describes how to extend basic circuit theory relating to voltages, currents, and resistances of metallic wire networks to include situations where the currents are no longer spatially uniform along the wire. This lays a foundation for a deeper understanding of the many new phenomena observed in meta-electromagnetic materials.   Examples of applications are included to support this new approach making Electromagnetic Behaviour of Metallic Wire Structures a comprehensive and ...

  10. Tensile deformation of NiTi wires.

    Science.gov (United States)

    Gall, Ken; Tyber, Jeff; Brice, Valerie; Frick, Carl P; Maier, Hans J; Morgan, Neil

    2005-12-15

    We examine the structure and properties of cold drawn Ti-50.1 at % Ni and Ti-50.9 at % Ni shape memory alloy wires. Wires with both compositions possess a strong fiber texture in the wire drawing direction, a grain size on the order of micrometers, and a high dislocation density. The more Ni rich wires contain fine second phase precipitates, while the wires with lower Ni content are relatively free of precipitates. The wire stress-strain response depends strongly on composition through operant deformation mechanisms, and cannot be explained based solely on measured differences in the transformation temperatures. We provide fundamental connections between the material structure, deformation mechanisms, and resulting stress-strain responses. The results help clarify some inconsistencies and common misconceptions in the literature. Ramifications on materials selection and design for emerging biomedical applications of NiTi shape memory alloys are discussed.

  11. Phosphorus in antique iron music wire.

    Science.gov (United States)

    Goodway, M

    1987-05-22

    Harpsichords and other wire-strung musical instruments were made with longer strings about the beginning of the 17th century. This change required stronger music wire. Although these changes coincided with the introduction of the first mass-produced steel (iron alloyed with carbon), carbon was not found in samples of antique iron harpsichord wire. The wire contained an amount of phosphorus sufficient to have impeded its conversion to steel, and may have been drawn from iron rejected for this purpose. The method used to select pig iron for wire drawing ensured the highest possible phosphorus content at a time when its presence in iron was unsuspected. Phosphorus as an alloying element has had the reputation for making steel brittle when worked cold. Nevertheless, in replicating the antique wire, it was found that lowcarbon iron that contained 0.16 percent phosphorus was easily drawn to appropriate gauges and strengths for restringing antique harpsichords.

  12. Prediction of material removal rate and surface roughness for wire electrical discharge machining of nickel using response surface methodology

    Directory of Open Access Journals (Sweden)

    Thangam Chinnadurai

    2016-12-01

    Full Text Available This study focuses on investigating the effects of process parameters, namely, Peak current (Ip, Pulse on time (Ton, Pulse off time (Toff, Water pressure (Wp, Wire feed rate (Wf, Wire tension (Wt, Servo voltage (Sv and Servo feed setting (Sfs, on the Material Removal Rate (MRR and Surface Roughness (SR for Wire electrical discharge machining (Wire-EDM of nickel using Taguchi method. Response Surface Methodology (RSM is adopted to evolve mathematical relationships between the wire cutting process parameters and the output variables of the weld joint to determine the welding input parameters that lead to the desired optimal wire cutting quality. Besides, using response surface plots, the interaction effects of process parameters on the responses are analyzed and discussed. The statistical software Mini-tab is used to establish the design and to obtain the regression equations. The developed mathematical models are tested by analysis-of-variance (ANOVA method to check their appropriateness and suitability. Finally, a comparison is made between measured and calculated results, which are in good agreement. This indicates that the developed models can predict the responses accurately and precisely within the limits of cutting parameter being used.

  13. Micro X-ray diffraction study of superelastic nickel-titanium orthodontic wires at different temperatures and stresses.

    Science.gov (United States)

    Iijima, M; Ohno, H; Kawashima, I; Endo, K; Brantley, W A; Mizoguchi, I

    2002-04-01

    The phase transformation behavior in three commercial nickel-titanium orthodontic wires having different transformation temperatures was studied by micro X-ray diffraction (micro-XRD). Micro-XRD spectra were obtained at three different included bending angles (135 degrees, 146 degrees and 157 degrees) and three different temperatures (25 degrees C, 37 degrees C and 60 degrees C). The regions analyzed by micro-XRD were within the separate areas of a given wire specimen that experienced only tensile or compressive strain. The intensity ratio (M002/A110) between the 002 peak for martensitic NiTi and the 110 peak for austenitic NiTi was employed as the index to the proportions of the martensite and austenite phases. The ratio of martensite to austenite increased in all three nickel-titanium wires with decreasing included bending angle (greater permanent bending deformation), and was lower within the compression area for all wires at all bending angles than within the tension area. Micro-XRD provides an effective method for quantitative evaluation of the proportions of these two phases in nickel-titanium orthodontic wires, even though considerable preferred crystallographic orientation exists because of the wire drawing process.

  14. The effect of temperature on basal tension and thyroarytenoid muscle contraction in an isolated rat glottis model.

    Science.gov (United States)

    Wang, Hsing-Won; Chu, Yueng-Hsiang; Chao, Pin-Zhir; Lee, Fei-Peng

    2014-10-01

    The pitch of voice is closely related to the vocal fold tension, which is the end result of coordinated movement of the intralaryngeal muscles, and especially the thyroarytenoid muscle. It is known that vocal quality may be affected by surrounding temperature; however, the effect of temperature on vocal fold tension is mostly unknown. Thus, the aim of this study was to evaluate the effect of temperature on isolated rat glottis and thyroarytenoid muscle contraction induced by electrical field stimulation. In vitro isometric tension of the glottis ring from 30 Sprague-Dawley rats was continuously recorded by the tissue bath method. Electrical field stimulation was applied to the glottis ring with two wire electrodes placed parallel to the glottis and connected to a direct-current stimulator. The tension changes of the rat glottis rings that were either untreated or treated with electrical field stimulation were recorded continuously at temperatures from 37 to 7 °C or from 7 to 37 °C. Warming from 7 to 37 °C increased the basal tension of the glottis rings and decreased the electrical field stimulation-induced glottis ring contraction, which was chiefly due to thyroarytenoid muscle contraction. In comparison, cooling from 37 to 7 °C decreased the basal tension and enhanced glottis ring contraction by electrical field stimulation. We concluded that warming increased the basal tension of the glottis in vitro and decreased the amplitude of electrical field stimulation-induced thyroarytenoid muscle contraction. Thus, vocal pitch and the fine tuning of vocal fold tension might be affected by temperature in vivo.

  15. Wire frame to MOVIE. BYU transfer program

    Energy Technology Data Exchange (ETDEWEB)

    Robbins, D.; Byers, L.D.; Benner, M.S.

    1982-12-01

    At SNLA, the primary computer-aided drafting tool is the Applicon Graphics System (AGS). The data base for mechanical parts on the AGS is a wire frame model. This report summarizes a method of adding surface information to the wire frame and passing this information up stream to MOVIE.BYU which is on a VAX computer and is used to produce shaded graphics pictures of the AGS wire frame model on a RAMTEK 9400 display terminal.

  16. Subchannel Analysis of Wire Wrapped SCWR Assembly

    OpenAIRE

    Jianqiang Shan; Henan Wang; Wei Liu; Linxing Song; Xuanxiang Chen; Yang Jiang

    2014-01-01

    Application of wire wrap spacers in SCWR can reduce pressure drop and obtain better mixing capability. As a consequence, the required coolant pumping power is decreased and the coolant temperature profile inside the fuel bundle is flattened which will obviously decrease the peak cladding temperature. The distributed resistance model for wire wrap was developed and implemented in ATHAS subchannel analysis code. The HPLWR wire wrapped assembly was analyzed. The results show that: (1) the assemb...

  17. Nondestructive Evaluation of Aircraft and Spacecraft Wiring

    Science.gov (United States)

    White, John E.; Tucholski, Edward J.; Green, Robert E., Jr.

    2004-01-01

    Spacecraft, and especially aircraft, often fry well past their original design lives and, therefore, the need to develop nondestructive evaluation procedures for inspection of vital structures in these craft is extremely important. One of the more recent problems is the degradation of wiring and wiring insulation. The present paper describes several nondestructive characterization methods which afford the possibility to detect wiring and insulation degradation in-situ prior to major problems with the safety of aircraft and spacecraft.

  18. IEE wiring regulations explained and illustrated

    CERN Document Server

    Scaddan, Brian

    2013-01-01

    The IEE Wiring Regulations Explained and Illustrated, Second Edition discusses the recommendations of the IEE Regulations for the Electrical Equipment of Buildings for the safe selection or erection of wiring installations. The book emphasizes earthing, bonding, protection, and circuit design of electrical wirings. The text reviews the fundamental requirements for safety, earthing systems, the earth fault loop impedance, and supplementary bonding. The book also describes the different types of protection, such as protection against mechanical damage, overcurrent, under voltage (which prevents

  19. Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: The Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL) provides a variety of research, design engineering and prototype fabrication services...

  20. Uniform wire segmentation algorithm of distributed interconnects

    Institute of Scientific and Technical Information of China (English)

    Yin Guoli; Lin Zhenghui

    2007-01-01

    A uniform wire segmentation algorithm for performance optimization of distributed RLC interconnects was proposed in this paper. The optimal wire length for identical segments and buffer size for buffer insertion are obtained through computation and derivation, based on a 2-pole approximation model of distributed RLC interconnect. For typical inductance value and long wires under 180nm technology, experiments show that the uniform wire segmentation technique proposed in the paper can reduce delay by about 27% ~ 56% , while requires 34%~69% less total buffer usage and thus 29% to 58% less power consumption. It is suitable for long RLC interconnect performance optimization.

  1. submitter Dynamical Models of a Wire Scanner

    CERN Document Server

    Barjau, Ana; Dehning, Bernd

    2016-01-01

    The accuracy of the beam profile measurements achievable by the current wire scanners at CERN is limited by the vibrations of their mechanical parts. In particular, the vibrations of the carbon wire represent the major source of wire position uncertainty which limits the beam profile measurement accuracy. In the coming years, due to the Large Hadron Collider (LHC) luminosity upgrade, a wire traveling speed up to 20 $m s^{−1}$ and a position measurement accuracy of the order of 1 μm will be required. A new wire scanner design based on the understanding of the wire vibration origin is therefore needed. We present the models developed to understand the main causes of the wire vibrations observed in an existing wire scanner. The development and tuning of those models are based on measurements and tests performed on that CERN proton synchrotron (PS) scanner. The final model for the (wire + fork) system has six degrees-of-freedom (DOF). The wire equations contain three different excitation terms: inertia...

  2. Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose:The Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL) provides a variety of research, design engineering and prototype fabrication services...

  3. Gold nanoparticle wire and integrated wire array for electronic detection of chemical and biological molecules

    Directory of Open Access Journals (Sweden)

    J. J. Diao

    2011-03-01

    Full Text Available Nanoparticle wire and integrated nanoparticle wire array have been prepared through a green technique: discontinuous vertical evaporation-driven colloidal deposition. The conducting gold nanoparticle wire made by this technique shows ability for the sensitive electronic detection of chemical and biological molecules due to its high surface to volume ratio. Furthermore, we also demonstrate a potential usage of integrated gold nanoparticle wire array for the localized detection.

  4. FE modeling of Cu wire bond process and reliability

    NARCIS (Netherlands)

    Yuan, C.A.; Weltevreden, E.R.; Akker, P. van den; Kregting, R.; Vreugd, J. de; Zhang, G.Q.

    2011-01-01

    Copper based wire bonding technology is widely accepted by electronic packaging industry due to the world-wide cost reduction actions (compared to gold wire bond). However, the mechanical characterization of copper wire differs from the gold wire; hence the new wire bond process setting and new bond

  5. FE modeling of Cu wire bond process and reliability

    NARCIS (Netherlands)

    Yuan, C.A.; Weltevreden, E.R.; Akker, P. van den; Kregting, R.; Vreugd, J. de; Zhang, G.Q.

    2011-01-01

    Copper based wire bonding technology is widely accepted by electronic packaging industry due to the world-wide cost reduction actions (compared to gold wire bond). However, the mechanical characterization of copper wire differs from the gold wire; hence the new wire bond process setting and new bond

  6. Tension-Type and Other Primary Headaches

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2005-12-01

    Full Text Available A review of the literature on tension-type and other “nonmigrainous” primary headaches is presented from Children’s Hospital of the King’s Daughters, Eastern Virginia Medical School, Norfolk, VA.

  7. The Dynamic Surface Tension of Water.

    Science.gov (United States)

    Hauner, Ines M; Deblais, Antoine; Beattie, James K; Kellay, Hamid; Bonn, Daniel

    2017-03-23

    The surface tension of water is an important parameter for many biological or industrial processes, and roughly a factor of 3 higher than that of nonpolar liquids such as oils, which is usually attributed to hydrogen bonding and dipolar interactions. Here we show by studying the formation of water drops that the surface tension of a freshly created water surface is even higher (∼90 mN m(-1)) than under equilibrium conditions (∼72 mN m(-1)) with a relaxation process occurring on a long time scale (∼1 ms). Dynamic adsorption effects of protons or hydroxides may be at the origin of this dynamic surface tension. However, changing the pH does not significantly change the dynamic surface tension. It also seems unlikely that hydrogen bonding or dipole orientation effects play any role at the relatively long time scale probed in the experiments.

  8. Transcutaneous Determination of Arterial Oxygen Tension

    Science.gov (United States)

    Fenner, A.; And Others

    1975-01-01

    Evaluated were two techniques (the conventional method and the new transcutaneous method) of measuring arterial oxygen tension in 20 severely ill preterm and term infants and in 70 healthy infants. (Author/CL)

  9. Psychology--tensions between objectivity and subjectivity.

    Science.gov (United States)

    Klempe, Sven Hroar

    2012-09-01

    The self is often defined in terms of its presentational appearances. This may easily end up in a denial of the internal aspects of the self, which is very often related to a tendency to avoid the tension between the internal and the external, but also between subjectivity and objectivity. In this paper this ambition is regarded in a historical perspective, in which Fichte and Hegel both represent attempts at abolishing the tension, whereas Kant and Kierkegaard represent the opposite. History shows that an eradication of the tension between subjectivity and objectivity implies a deterioration of psychology as well. Thus the conclusion is that psychology is primarily to be defined in terms of the tension between subjectivity and objectivity, which requires an accurate understanding and the inclusion of both of them.

  10. Oxygen tension level and human viral infections.

    Science.gov (United States)

    Morinet, Frédéric; Casetti, Luana; François, Jean-Hugues; Capron, Claude; Pillet, Sylvie

    2013-09-01

    The role of oxygen tension level is a well-known phenomenon that has been studied in oncology and radiotherapy since about 60 years. Oxygen tension may inhibit or stimulate propagation of viruses in vitro as well as in vivo. In turn modulating oxygen metabolism may constitute a novel approach to treat viral infections as an adjuvant therapy. The major transcription factor which regulates oxygen tension level is hypoxia-inducible factor-1 alpha (HIF-1α). Down-regulating the expression of HIF-1α is a possible method in the treatment of chronic viral infection such as human immunodeficiency virus infection, chronic hepatitis B and C viral infections and Kaposi sarcoma in addition to classic chemotherapy. The aim of this review is to supply an updating concerning the influence of oxygen tension level in human viral infections and to evoke possible new therapeutic strategies regarding this environmental condition. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Wired

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    迄今为止,已有45000个项目借助在线捐赠成功完成众筹,金额总计达5亿美元以上。其中绝大部分(据估计为80%)来自Kickstarter网站,这家网站如今几乎成了“众筹”这一术语的代名词。

  12. Tension Hydrothorax Related to Disseminated Endometriosis

    Directory of Open Access Journals (Sweden)

    AnnaKate Deal, MD

    2016-01-01

    Full Text Available We present the case of a 34-year-old woman presenting to the emergency department (ED with dyspnea, cough, and fever. She was found to have a tension hydrothorax and was treated with ultrasound-guided thoracentesis in the ED. Subsequent inpatient evaluation showed the patient had disseminated endometriosis. Tension hydrothorax has not been previously described in the literature as a complication of this disease.

  13. The Tensions of In Situ Visualization.

    Science.gov (United States)

    Moreland, Kenneth

    2016-01-01

    In situ visualization is the coupling of visualization software with a simulation or other data producer to process the data "in memory" before the data are offloaded to a storage system. Although in situ visualization provides superior analysis, it has implementation tradeoffs resulting from conflicts with some traditional expected requirements. Numerous conflicting requirements create tensions that lead to difficult implementation tradeoffs. This article takes a look at the most prevailing tensions of in situ visualization.

  14. THERMO-MECHANICALLY PROCESSED ROLLED WIRE FOR HIGH-STRENGTH ON-BOARD WIRE

    Directory of Open Access Journals (Sweden)

    V. A. Lutsenko

    2011-01-01

    Full Text Available It is shown that at twisting of wire of diameter 1,83 mm, produced by direct wire drawing of thermomechanically processed rolled wire of diameter 5,5 mm of steel 90, metal stratification is completely eliminated at decrease of carbon, manganese and an additional alloying of chrome.

  15. Observation of ultrasonic guided wave propagation behaviours in pre-stressed multi-wire structures.

    Science.gov (United States)

    Liu, Xiucheng; Wu, Bin; Qin, Fei; He, Cunfu; Han, Qiang

    2017-01-01

    Ultrasonic guided wave (UGW) is a promising technique for nondestructive testing of pre-stressed multi-wire structures, such as steel strand and wire rope. The understanding of the propagation behaviours of UGW in these structures is a priority to applications. In the present study, first the properties of the UGW missing frequency band in the pre-stressed seven-wire steel strand is experimentally examined. The high correlation between the observed results and the previously published findings proves the feasibility of the magnetostrictive sensor (MsS) based testing method. The evolution of missing frequency band of UGW in slightly tensioned steel strand is discussed. Two calibration equations representing the relationship between the missing band parameters and the tensile force are given to derive a new tensile force measurement method, which is capable of measuring an incremental of stress of approximately 3MPa. Second, the effects of tensile force on the UGW propagation behaviours in three types of complicated steel wire ropes are alternatively investigated based on the short time Fourier transform (STFT) results of the received direct transmission wave (DTW) signals. The observed inherent missing frequency band of the longitudinal mode UGW in the pre-stressed steel wire rope and its shifting to a higher frequency range as the increases of the applied tensile force are reported for the first time. The influence of applied tensile force on the amplitude of the DTW signal and the unique UGW energy jump behaviour observed in a wire rope of 16.0mm, 6×Fi(29)+IWRC are also investigated, despite the fact that they cannot yet be explained.

  16. Microstructural evolution and deformation behavior of twinning-induced plasticity (TWIP) steel during wire drawing

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Joong-Ki [Graduate Institute of Ferrous Technology, POSTECH, Pohang 790-784 (Korea, Republic of); Steel Products Research Group, Technical Research Laboratories, POSCO, Pohang 790-785 (Korea, Republic of); Yi, Il-Cheol [Graduate Institute of Ferrous Technology, POSTECH, Pohang 790-784 (Korea, Republic of); Son, Il-Heon; Yoo, Jang-Yong [Steel Products Research Group, Technical Research Laboratories, POSCO, Pohang 790-785 (Korea, Republic of); Kim, Byoungkoo [Materials Technology Development Team, DHIC, Changwon 642-792 (Korea, Republic of); Zargaran, A. [Graduate Institute of Ferrous Technology, POSTECH, Pohang 790-784 (Korea, Republic of); Kim, Nack J., E-mail: njkim@postech.ac.kr [Graduate Institute of Ferrous Technology, POSTECH, Pohang 790-784 (Korea, Republic of)

    2015-09-17

    The effect of wire drawing on the microstructural evolution and deformation behavior of Fe–Mn–Al–C twinning-induced plasticity (TWIP) steel has been investigated. The inhomogeneities of the stress state, texture, microstructure, and mechanical properties were clarified over the cross section of drawn wire with the aid of numerical simulation, Schmid factor analysis, and electron backscatter diffraction (EBSD) techniques. The analysis of texture in drawn wire shows that a mixture of <111> and <100> fiber texture was developed with strain; however, the distribution of <111> and <100> fibers was inhomogeneous along the radial direction of wire due to uneven strain distribution and different stress state along the radial direction. It has also been shown that the morphology, volume fraction, and variant system of twins as well as twinning rate were dependent on the imposed stress state. The surface area was subjected to larger strain and more complex stress state involving compression, shear, and tension than the center area, resulting in a larger twin volume fraction and more twin variants in the former than in the latter at all the strain levels. While the surface area was saturated with twins at an early stage of drawing, the center area was not saturated with twins even at fracture, implying that the fracture of wire were initiated at the surface area because of the exhaustion of ductility due to twinning. Based on these results, it is suggested that imposing a uniform strain distribution along the radial direction of wire by the control of processing conditions such as die angle and amount of reduction per pass is necessary to increase the drawing limit of TWIP steel.

  17. Oxygen tension level and human viral infections

    Energy Technology Data Exchange (ETDEWEB)

    Morinet, Frédéric, E-mail: frederic.morinet@sls.aphp.fr [Centre des Innovations Thérapeutiques en Oncologie et Hématologie (CITOH), CHU Saint-Louis, Paris (France); Université Denis Diderot, Sorbonne Paris Cité Paris, Paris (France); Casetti, Luana [Institut Cochin INSERM U1016, Paris (France); François, Jean-Hugues; Capron, Claude [Institut Cochin INSERM U1016, Paris (France); Laboratoire d' Hématologie, Hôpital Ambroise Paré, Boulogne (France); Université de Versailles Saint-Quentin en Yvelynes, Versailles (France); Pillet, Sylvie [Laboratoire de Bactériologie-Virologie-Hygiène, CHU de Saint-Etienne, Saint-Etienne (France); Université de Lyon et Université de Saint-Etienne, Jean Monnet, GIMAP EA3064, F-42023 Saint-Etienne, Lyon (France)

    2013-09-15

    The role of oxygen tension level is a well-known phenomenon that has been studied in oncology and radiotherapy since about 60 years. Oxygen tension may inhibit or stimulate propagation of viruses in vitro as well as in vivo. In turn modulating oxygen metabolism may constitute a novel approach to treat viral infections as an adjuvant therapy. The major transcription factor which regulates oxygen tension level is hypoxia-inducible factor-1 alpha (HIF-1α). Down-regulating the expression of HIF-1α is a possible method in the treatment of chronic viral infection such as human immunodeficiency virus infection, chronic hepatitis B and C viral infections and Kaposi sarcoma in addition to classic chemotherapy. The aim of this review is to supply an updating concerning the influence of oxygen tension level in human viral infections and to evoke possible new therapeutic strategies regarding this environmental condition. - Highlights: • Oxygen tension level regulates viral replication in vitro and possibly in vivo. • Hypoxia-inducible factor 1 (HIF-1α) is the principal factor involved in Oxygen tension level. • HIF-1α upregulates gene expression for example of HIV, JC and Kaposi sarcoma viruses. • In addition to classical chemotherapy inhibition of HIF-1α may constitute a new track to treat human viral infections.

  18. Tension-oriented cell divisions limit anisotropic tissue tension in epithelial spreading during zebrafish epiboly.

    Science.gov (United States)

    Campinho, Pedro; Behrndt, Martin; Ranft, Jonas; Risler, Thomas; Minc, Nicolas; Heisenberg, Carl-Philipp

    2013-12-01

    Epithelial spreading is a common and fundamental aspect of various developmental and disease-related processes such as epithelial closure and wound healing. A key challenge for epithelial tissues undergoing spreading is to increase their surface area without disrupting epithelial integrity. Here we show that orienting cell divisions by tension constitutes an efficient mechanism by which the enveloping cell layer (EVL) releases anisotropic tension while undergoing spreading during zebrafish epiboly. The control of EVL cell-division orientation by tension involves cell elongation and requires myosin II activity to align the mitotic spindle with the main tension axis. We also found that in the absence of tension-oriented cell divisions and in the presence of increased tissue tension, EVL cells undergo ectopic fusions, suggesting that the reduction of tension anisotropy by oriented cell divisions is required to prevent EVL cells from fusing. We conclude that cell-division orientation by tension constitutes a key mechanism for limiting tension anisotropy and thus promoting tissue spreading during EVL epiboly.

  19. Grain-resolved analysis of localized deformation in nickel-titanium wire under tensile load

    Science.gov (United States)

    Sedmák, P.; Pilch, J.; Heller, L.; Kopeček, J.; Wright, J.; Sedlák, P.; Frost, M.; Šittner, P.

    2016-08-01

    The stress-induced martensitic transformation in tensioned nickel-titanium shape-memory alloys proceeds by propagation of macroscopic fronts of localized deformation. We used three-dimensional synchrotron x-ray diffraction to image at micrometer-scale resolution the grain-resolved elastic strains and stresses in austenite around one such front in a prestrained nickel-titanium wire. We found that the local stresses in austenite grains are modified ahead of the nose cone-shaped buried interface where the martensitic transformation begins. Elevated shear stresses at the cone interface explain why the martensitic transformation proceeds in a localized manner. We established the crossover from stresses in individual grains to a continuum macroscopic internal stress field in the wire and rationalized the experimentally observed internal stress field and the topology of the macroscopic front by means of finite element simulations of the localized deformation.

  20. Comparison of optimization techniques for MRR and surface roughness in wire EDM process for gear cutting

    Directory of Open Access Journals (Sweden)

    K.D. Mohapatra

    2016-11-01

    Full Text Available The objective of the present work is to use a suitable method that can optimize the process parameters like pulse on time (TON, pulse off time (TOFF, wire feed rate (WF, wire tension (WT and servo voltage (SV to attain the maximum value of MRR and minimum value of surface roughness during the production of a fine pitch spur gear made of copper. The spur gear has a pressure angle of 20⁰ and pitch circle diameter of 70 mm. The wire has a diameter of 0.25 mm and is made of brass. Experiments were conducted according to Taguchi’s orthogonal array concept with five factors and two levels. Thus, Taguchi quality loss design technique is used to optimize the output responses carried out from the experiments. Another optimization technique i.e. desirability with grey Taguchi technique has been used to optimize the process parameters. Both the optimized results are compared to find out the best combination of MRR and surface roughness. A confirmation test was carried out to identify the significant improvement in the machining performance in case of Taguchi quality loss. Finally, it was concluded that desirability with grey Taguchi technique produced a better result than the Taguchi quality loss technique in case of MRR and Taguchi quality loss gives a better result in case of surface roughness. The quality of the wire after the cutting operation has been presented in the scanning electron microscopy (SEM figure.

  1. Bird on a (live) wire

    Energy Technology Data Exchange (ETDEWEB)

    Farr, M.

    2003-09-30

    Bird mortality as a result of contact with power lines is discussed. U. S. statistics are cited, according to which 174 million birds annually die as a result of contact with power lines, specifically when birds touch two phases of current at the same time. Raptors are particularly vulnerable to power-line electrocution due to their habit of perching on the highest vantage point available as they survey the ground for prey. Hydro lines located in agricultural areas, with bodies of water on one side and fields on the other, also obstruct flight of waterfowl as dusk and dawn when visibility is low. Various solutions designed to minimize the danger to birds are discussed. Among these are: changing the configuration of wires and cross arms to make them more visible to birds in flight and less tempting as perches, and adding simple wire markers such as flags, balloons, and coloured luminescent clips that flap and twirl in the wind. There is no evidence of any coordinated effort to deal with this problem in Ontario. However, a report is being prepared for submission to Environment Canada outlining risks to birds associated with the growing number of wind turbine power generators (negligible compared with power lines and communications towers), and offering suggestions on remedial measures. The Fatal Light Awareness Program (FLAP) also plans to lobby the Canadian Wildlife Service to discuss the possibility of coordinating efforts to monitor, educate about and ultimately reduce this form of bird mortality.

  2. In situ droplet surface tension and viscosity measurements in gas metal arc welding

    Science.gov (United States)

    Bachmann, B.; Siewert, E.; Schein, J.

    2012-05-01

    In this paper, we present an adaptation of a drop oscillation technique that enables in situ measurements of thermophysical properties of an industrial pulsed gas metal arc welding (GMAW) process. Surface tension, viscosity, density and temperature were derived expanding the portfolio of existing methods and previously published measurements of surface tension in pulsed GMAW. Natural oscillations of pure liquid iron droplets are recorded during the material transfer with a high-speed camera. Frame rates up to 30 000 fps were utilized to visualize iron droplet oscillations which were in the low kHz range. Image processing algorithms were employed for edge contour extraction of the droplets and to derive parameters such as oscillation frequencies and damping rates along different dimensions of the droplet. Accurate surface tension measurements were achieved incorporating the effect of temperature on density. These are compared with a second method that has been developed to accurately determine the mass of droplets produced during the GMAW process which enables precise surface tension measurements with accuracies up to 1% and permits the study of thermophysical properties also for metals whose density highly depends on temperature. Thermophysical properties of pure liquid iron droplets formed by a wire with 1.2 mm diameter were investigated in a pulsed GMAW process with a base current of 100 A and a pulse current of 600 A. Surface tension and viscosity of a sample droplet were 1.83 ± 0.02 N m-1 and 2.9 ± 0.3 mPa s, respectively. The corresponding droplet temperature and density are 2040 ± 50 K and 6830 ± 50 kg m-3, respectively.

  3. Thermoprocessing and wire drawing behaviour of ultra high strength steel wires

    OpenAIRE

    Bargujer, S.S.; Singh, Parvinder; Raizada, Vikas

    2016-01-01

    The thermo-processing of piano wire rods is carried out in the lead bath. This experimentation is carried out under industrial conditions. The investigation is done to examine the effect of austenitic time, lead bath time and wire diameter on mechanical properties of lead patented wire. The Taguchi technique is adopted for optimization of thermo-processing of hypereutectoid steel wires. The lead patented wire of diameter 7.00 mm is cold drawn in a sequence of conical converging dies. The best...

  4. REMEDY OF WIRE LAG IN WIRE ELECTRICAL DISCHARGE MACHINING (WEDM

    Directory of Open Access Journals (Sweden)

    S. K. SINHA

    2010-12-01

    Full Text Available WEDM is extensively used these days for generating complex geometries with tight tolerances on difficult-tomachine materials. Therefore, demand for improvement in precision has been ever increasing. The main source of inaccuracy is wire-lag, the cause and effect of which is well-known. Research has been going on to overcome this drawback. So far, the techniques suggested for improvement in accuracy are, in general, based on monitoring the machining process at hardware-level, which is not only tedious but involves extra expenditure also. In the present paper, a software approach for improvement in accuracy is described, which does not require any additional investment on the machine, and still gives very good results.

  5. High Performance Control of Induction Motor for Wire Drawing Machine Based on DSP

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, H.G.; Park, S.G.; Jin, S.O. [Changwon National University (Korea, Republic of); Kwon, Y.J. [IMI Engineering Co. (Korea, Republic of)

    1997-04-01

    This paper describes a high performance fully digital implementation of 15 Kw Induction Motor servo system for WDM(Wire Drawing Machine). On the basis of vector control principle, the system is controlled by a DSP(TMS320C31) and 18254 timer. Space vector modulation is used as the inverter switching strategy. The system is capable to improve the performance on the four quadrant operation for back-pull tension control. The proposed control scheme is verified by laboratory experiment in terms of control action, dynamic response and robustness. (author). 4 refs., 8 figs.

  6. Topological transition in coated wire medium

    CERN Document Server

    Gorlach, Maxim A; Slobozhanyuk, Alexey P; Bogdanov, Andrey A; Belov, Pavel A

    2016-01-01

    We develop a theory of nonlocal homogenization for metamaterial consisting of parallel metallic wires with dielectric coating. It is demonstrated that manipulation of dielectric contrast between wire dielectric shell and host material results in switching of metamaterial dispersion regime from elliptic to the hyperbolic one, i.e. the topological transition takes place. We confirm our theoretical predictions by full-wave numerical simulations.

  7. Kirschner Wire Breakage during Removal Requiring Retrieval

    Directory of Open Access Journals (Sweden)

    Kai Yuen Wong

    2016-01-01

    Full Text Available Kirschner wires (K-wires are widely used for fixation of fractures and dislocations in the hand as they are readily available, reliable, and cost-effective. Complication rates of up to 18% have been reported. However, K-wire breakage during removal is rare. We present one such case illustrating a simple technique for retrieval. A 35-year-old male presented with a distal phalanx fracture of his right middle finger. This open fracture was treated with K-wire fixation. Postoperatively, he developed a pin site infection with associated finger swelling. The K-wire broke during removal with the proximal piece completely retained in his middle phalanx. To minimise risk of osteomyelitis, the K-wire was removed with a novel surgical technique. He had full return of hand function. Intraoperative K-wire breakage has a reported rate of 0.1%. In our case, there was no obvious cause of breakage and the patient denied postoperative trauma. On the other hand, pin site infections are much more common with reported rates of up to 7% in the hand or wrist. K-wire fixation is a simple method for bony stabilisation but can be a demanding procedure with complications often overlooked. It is important to be aware of the potential sequelae.

  8. Flywheel system using wire-wound rotor

    Energy Technology Data Exchange (ETDEWEB)

    Chiao, Edward Young; Bender, Donald Arthur; Means, Andrew E.; Snyder, Philip K.

    2016-06-07

    A flywheel is described having a rotor constructed of wire wound onto a central form. The wire is prestressed, thus mitigating stresses that occur during operation. In another aspect, the flywheel incorporates a low-loss motor using electrically non-conducting permanent magnets.

  9. Microfabricated wire arrays for Z-pinch.

    Energy Technology Data Exchange (ETDEWEB)

    Spahn, Olga Blum; Rowen, Adam M.; Cich, Michael Joseph; Peake, Gregory Merwin; Arrington, Christian L.; Nash, Thomas J.; Klem, John Frederick; Romero, Dustin Heinz

    2008-10-01

    Microfabrication methods have been applied to the fabrication of wire arrays suitable for use in Z. Self-curling GaAs/AlGaAs supports were fabricated as an initial route to make small wire arrays (4mm diameter). A strain relief structure that could be integrated with the wire was designed to allow displacements of the anode/cathode connections in Z. Electroplated gold wire arrays with integrated anode/cathode bus connections were found to be sufficiently robust to allow direct handling. Platinum and copper plating processes were also investigated. A process to fabricate wire arrays on any substrate with wire thickness up to 35 microns was developed. Methods to handle and mount these arrays were developed. Fabrication of wire arrays of 20mm diameter was demonstrated, and the path to 40mm array fabrication is clear. With some final investment to show array mounting into Z hardware, the entire process to produce a microfabricated wire array will have been demonstrated.

  10. WIRED magazine announces rave awards nominees

    CERN Multimedia

    2002-01-01

    WIRED Magazine has anounced the nominees for its fourth annual WIRED Rave Awards, celebrating innovation and the individuals transforming commerce and culture. Jeffrey Hangst of the University of Aarhus has been nominated in the science category, for his work on the ATHENA Experiment, CERN (1/2 page).

  11. Hot-wire anemometer for spirography.

    Science.gov (United States)

    Plakk, P; Liik, P; Kingisepp, P H

    1998-01-01

    The use of a constant temperature hot-wire anemometer flow sensor for spirography is reported. The construction, operating principles and calibration procedure of the apparatus are described, and temperature compensation method is discussed. Frequency response is studied. It is shown that this hot-wire flow transducer satisfies common demands with respect to accuracy, response time and temperature variations.

  12. Transcolonic Migration of Retained Epicardial Pacing Wires

    Directory of Open Access Journals (Sweden)

    Sara Gonzales

    2015-01-01

    Full Text Available Temporary epicardial pacing wires are associated with rare complications. Most of these occur in the chest. Even rarer are complications that occur within the abdomen. We report a case of migrating epicardial pacing wires entering the abdomen and penetrating the transverse colon found incidentally on colonoscopy in an asymptomatic patient.

  13. Oxygen tension affects lubricin expression in chondrocytes.

    Science.gov (United States)

    Hatta, Taku; Kishimoto, Koshi N; Okuno, Hiroshi; Itoi, Eiji

    2014-10-01

    We assessed the effects of oxygen tension on lubricin expression in bovine chondrocytes and cartilage explants and a role for hypoxia-inducible transcription factor (HIF)-1α in regulating lubricin expression was investigated using a murine chondroprogenitor cell line, ATDC5, and bovine chondrocytes isolated from superficial and middle/deep zones of femoral cartilage. ATDC5 cells and bovine chondrocytes were cultured in micromass under different oxygen tensions (21%, 5%, and 1%). ATDC5 cells and middle/deep zone chondrocytes that initially had low lubricin expression levels were also cultured with or without transforming growth factor (TGF)-β1. Quantitative reverse transcription (RT)-PCR was used to determine lubricin and chondrogenic marker gene mRNA levels and immunohistochemistry was used to assess lubricin protein expression. Explant cartilage plugs cultured under different oxygen tensions were also subjected to immunohistological analysis for lubricin. HIF-1α gene silencing was achieved by electroporatic transfer into ATDC5 cells. A low oxygen tension reduced lubricin gene expression levels in bovine superficial chondrocytes, TGF-β1-treated middle/deep zone chondrocytes, and TGF-β1-treated ATDC5 cells. Lubricin expression in explant cartilage was also suppressed under hypoxia. HIF-1α gene silencing in ATDC5 cells attenuated the lubricin expression response to the oxygen tension. These results corroborate with previous studies that the oxygen tension regulates lubricin gene expression and suggest that HIF-1α plays an important role in this regulation. The normal distribution of lubricin in articular cartilage may be due to the hypoxic oxygen environment of cartilage as it is an avascular tissue. An oxygen tension gradient may be a key factor for engineering cartilage tissue with a layered morphology.

  14. Emergency percutaneous needle decompression for tension pneumoperitoneum

    Directory of Open Access Journals (Sweden)

    Körner Markus

    2011-05-01

    Full Text Available Abstract Background Tension pneumoperitoneum as a complication of iatrogenic bowel perforation during endoscopy is a dramatic condition in which intraperitoneal air under pressure causes hemodynamic and ventilatory compromise. Like tension pneumothorax, urgent intervention is required. Immediate surgical decompression though is not always possible due to the limitations of the preclinical management and sometimes to capacity constraints of medical staff and equipment in the clinic. Methods This is a retrospective analysis of cases of pneumoperitoneum and tension pneumoperitoneum due to iatrogenic bowel perforation. All patients admitted to our surgical department between January 2005 and October 2010 were included. Tension pneumoperitoneum was diagnosed in those patients presenting signs of hemodynamic and ventilatory compromise in addition to abdominal distension. Results Between January 2005 and October 2010 eleven patients with iatrogenic bowel perforation were admitted to our surgical department. The mean time between perforation and admission was 36 ± 14 hrs (range 30 min - 130 hrs, between ER admission and begin of the operation 3 hrs and 15 min ± 47 min (range 60 min - 9 hrs. Three out of eleven patients had clinical signs of tension pneumoperitoneum. In those patients emergency percutaneous needle decompression was performed with a 16G venous catheter. This improved significantly the patients' condition (stabilization of vital signs, reducing jugular vein congestion, bridging the time to the start of the operation. Conclusions Hemodynamical and respiratory compromise in addition to abdominal distension shortly after endoscopy are strongly suggestive of tension pneumoperitoneum due to iatrogenic bowel perforation. This is a rare but life threatening condition and it can be managed in a preclinical and clinical setting with emergency percutaneous needle decompression like tension pneumothorax. Emergency percutaneous decompression is no

  15. Exploratory experimental investigations on post-tensioned structural glass beams

    DEFF Research Database (Denmark)

    Louter, C.; Nielsen, Jens Henrik; Belis, J.

    2013-01-01

    This paper discusses two projects on post-tensioned glass beams, performed at EPFL and DTU, respectively. In these projects small scale glass beams (length of 1.5m and 1m) are post-tensioned by means of steel threaded rods tensioned at the beam ends. The purpose of post-tensioning glass beams...

  16. Wire and Cable Cold Bending Test

    Science.gov (United States)

    Colozza, Anthony

    2010-01-01

    One of the factors in assessing the applicability of wire or cable on the lunar surface is its flexibility under extreme cold conditions. Existing wire specifications did not address their mechanical behavior under cold, cryogenic temperature conditions. Therefore tests were performed to provide this information. To assess this characteristic 35 different insulated wire and cable pieces were cold soaked in liquid nitrogen. The segments were then subjected to bending and the force was recorded. Any failure of the insulation or jacketing was also documented for each sample tested. The bending force tests were performed at room temperature to provide a comparison to the change in force needed to bend the samples due to the low temperature conditions. The results from the bending tests were plotted and showed how various types of insulated wire and cable responded to bending under cold conditions. These results were then used to estimate the torque needed to unroll the wire under these low temperature conditions.

  17. Development and Manufacture of Bi-2223 Wires

    Science.gov (United States)

    Kobayashi, Shin-Ichi

    This chapter reviews Ag-sheathed (Bi, Pb)2Sr2Ca2Cu3Ox (Bi-2223) wire made by the powder-in-tube technique (PIT). The currently leading high-temperature superconductors (HTS) wire technology for practical use is Bi-2223 wire, made by the controlled over-pressure (CT-OP) sintering process. The CT-OP process uses pressures up to 30MPa during heat treatment. The technique densifies the Bi-2223 filaments and enhances the uniformity of the electrical and mechanical performance in the Bi-2223 wire. Today, Bi-2223 wires are used in most HTS applications, such as power cables, many kinds of magnets, and motors for ship propulsion and electric vehicles.

  18. Evaluation of cable tension sensors of FAST reflector from the perspective of EMI

    Science.gov (United States)

    Zhu, Ming; Wang, Qiming; Egan, Dennis; Wu, Mingchang; Sun, Xiao

    2016-06-01

    The active reflector of FAST (five-hundred-meter aperture spherical radio telescope) is supported by a ring beam and a cable-net structure, in which nodes are actively controlled to form series of real-time paraboloids. To ensure the security and stability of the supporting structure, tension must be monitored for some typical cables. Considering the stringent requirements in accuracy and long-term stability, magnetic flux sensor, vibrating wire strain gauge and fiber bragg grating strain gauge are screened for the cable tension monitoring of the supporting cable-net. Specifically, receivers of radio telescopes have strict restriction on electro magnetic interference (EMI) or radio frequency interference (RFI). These three types of sensors are evaluated from the view of EMI/RFI. Firstly, these fundamentals are theoretically analyzed. Secondly, typical sensor signals are collected in the time and analyzed in the frequency domain, which shows the characteristic in the frequency domain. Finally, typical sensors are tested in an anechoic chamber to get the EMI levels. Theoretical analysis shows that Fiber Bragg Grating strain gauge itself will not lead to EMI/RFI. According to GJB151A, frequency domain analysis and test results show that for the vibrating wire strain gauge and magnetic flux sensor themselves, testable EMI/RFI levels are typically below the background noise of the anechoic chamber. FAST finally choses these three sensors as the monitoring sensors of its cable tension. The proposed study is also a reference to the monitoring equipment selection of other radio telescopes and large structures.

  19. Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: A biomechanical study.

    Science.gov (United States)

    Dickens, Aaron J; Salas, Christina; Rise, LeRoy; Murray-Krezan, Cristina; Taha, Mahmoud Reda; DeCoster, Thomas A; Gehlert, Rick J

    2015-01-01

    We performed a simple biomechanical study to compare the fixation strength of titanium mesh with traditional tension-band augmentation, which is a standard treatment for transverse patella fractures. We hypothesised that titanium mesh augmentation is not inferior in fixation strength to the standard treatment. Twenty-four synthetic patellae were tested. Twelve were fixed with stainless steel wire and parallel cannulated screws. Twelve were fixed with parallel cannulated screws, augmented with anterior titanium mesh and four screws. A custom test fixture was developed to simulate a knee flexed to 90°. A uniaxial force was applied to the simulated extensor mechanism at this angle. A non-inferiority study design was used to evaluate ultimate force required for failure of each construct as a measure of fixation strength. Stiffness of the bone/implant construct, fracture gap immediately prior to failure, and modes of failure are also reported. The mean difference in force at failure was -23.0 N (95% CI: -123.6 to 77.6N) between mesh and wire constructs, well within the pre-defined non-inferiority margin of -260 N. Mean stiffness of the mesh and wire constructs were 19.42 N/mm (95% CI: 18.57-20.27 N/mm) and 19.49 N/mm (95% CI: 18.64-20.35 N/mm), respectively. Mean gap distance for the mesh constructs immediately prior to failure was 2.11 mm (95% CI: 1.35-2.88 mm) and 3.87 mm (95% CI: 2.60-5.13 mm) for wire constructs. Titanium mesh augmentation is not inferior to tension-band wire augmentation when comparing ultimate force required for failure in this simplified biomechanical model. Results also indicate that stiffness of the two constructs is similar but that the mesh maintains a smaller fracture gap prior to failure. The results of this study indicate that the use of titanium mesh plating augmentation as a low-profile alternative to tension-band wiring for fixation of transverse patella fractures warrants further investigation. Copyright © 2015 Elsevier Ltd. All

  20. Tension Distribution in a Tendon-Driven Robotic Finger

    Science.gov (United States)

    Abdallah, Muhammad E. (Inventor); Platt, Robert (Inventor); Wampler, II, Charles W. (Inventor)

    2013-01-01

    A method is provided for distributing tension among tendons of a tendon-driven finger in a robotic system, wherein the finger characterized by n degrees of freedom and n+1 tendons. The method includes determining a maximum functional tension and a minimum functional tension of each tendon of the finger, and then using a controller to distribute tension among the tendons, such that each tendon is assigned a tension value less than the maximum functional tension and greater than or equal to the minimum functional tension. The method satisfies the minimum functional tension while minimizing the internal tension in the robotic system, and satisfies the maximum functional tension without introducing a coupled disturbance to the joint torques. A robotic system includes a robot having at least one tendon-driven finger characterized by n degrees of freedom and n+1 tendons, and a controller having an algorithm for controlling the tendons as set forth above.

  1. INTERFACIAL DEBONDING OF COATED-FIBER-REINFORCED COMPOSITES UNDER TENSION-TENSION CYCLIC LOADING

    Institute of Scientific and Technical Information of China (English)

    Shi Zhifei; Zhou Limin

    2000-01-01

    A new degradation function of the friction coefficient is used. Based on the double shear-lag model and Paris formula, the interfacial damage of coated fiber-reinforced composites under tension-tension cyclic loading is studied. The effects of strength and thickness of the coating materials on the debond stress, debond rate as well as debond length are simulated.

  2. Transcutaneous oxygen tension in imminent foot gangrene

    DEFF Research Database (Denmark)

    Tønnesen, K H

    1978-01-01

    Transcutaneous oxygen tension at 44 degree C and maximal isotope clearance (90m Tc-pretechnetate + histramine) just proximal to the 1st toe and systolic toe blood pressure (strain gauge) were studied on a tilt table in patients with various degrees of obstructive arteriosclerotic disease. In legs...... the arterioles into the tissue sink and counter current gas shunting. The hypoxia in spite of a positive perfusion pressure up to 50 mmHg explains our experience that ischemic ulcers in feet such low pressures never heal.......Transcutaneous oxygen tension at 44 degree C and maximal isotope clearance (90m Tc-pretechnetate + histramine) just proximal to the 1st toe and systolic toe blood pressure (strain gauge) were studied on a tilt table in patients with various degrees of obstructive arteriosclerotic disease. In legs...... with moderate obstruction, the oxygen tension reached zero at a toe systolic blood pressure of 5--10 mmHg (tilt toe up) and reached arterial oxygen tension at about 50 to 70 mmHg (tilt toe down). In legs withsevere arterial obstruction and ischaemic rest pain, oxygen tension rose from zero not before systolic...

  3. Phonon spectra in quantum wires

    Directory of Open Access Journals (Sweden)

    Ilić Dušan

    2007-01-01

    Full Text Available Green's function method, adjusted to bound crystalline structures, was applied to obtain the phonon dispersion law in quantum wires. The condition of the existence of small mechanical atom movements defining phonon spectra can be found by solving the secular equation. This problem was presented graphically for different boundary parameters. The presence of boundaries, as well as the change of boundary parameters, leads to the appearance of new properties of the layered structure. The most important feature is that, beside the allowed energy zones (which are continuous as in the bulk structure, zones of forbidden states appear. Different values of the boundary parameters lead to the appearance of lower and upper energy gaps, or dispersion branches spreading out of the bulk energy zone. The spectra of phonons in corresponding unbound structures were correlated to those in bound structures.

  4. Influence of constriction, wall tension, smooth muscle activation and cellular deformation on rat resistance artery vasodilator reactivity.

    Science.gov (United States)

    Colton, Ilsley; Mandalà, Maurizio; Morton, Jude; Davidge, Sandra T; Osol, George

    2012-01-01

    This study investigated how vasoconstriction (tone), wall tension, smooth muscle activation, and vascular wall deformation influence resistance artery vasodilator reactivity. Resistance arteries, from two different regional circulations (splanchnic, uterine) and from pregnant and non-pregnant rats, were cannulated and pressurized, or mounted on a wire myograph under isometric conditions prior to being exposed to both endothelium-dependent (acetylcholine, ACh) and -independent (sodium nitroprusside, SNP) vasodilator agonists. A consistent pattern of reduced vasodilator sensitivity was noted as a function of extent of preconstriction for both agonists noted in pressurized arteries. A similar pattern regarding activation was noted in wire-mounted arteries in response to SNP but not ACh. Wall tension proved to be a major determinant of vascular smooth muscle vasodilator reactivity and its normalization reversed this pattern, as more constricted vessels were more sensitive to ACh relaxation without any change in SNP sensitivity, suggesting that endothelial deformation secondary to vasoconstriction augments its vasodilator output. To our knowledge, this is the first study to dissect out the complex interplay between biophysical forces impinging on VSM (pressure, wall tension), the ambient level of tone (vasoconstriction, smooth muscle cell activation), and consequences of cellular (particularly endothelial) deformation secondary to constriction in determining resistance artery vasodilatory reactivity.

  5. Elastic properties and mechanical tension of graphene

    Science.gov (United States)

    Ramírez, R.; Herrero, C. P.

    2017-01-01

    Room-temperature simulations of graphene have been performed as a function of the mechanical tension of the layer. Finite-size effects are accurately reproduced by an acoustic dispersion law for the out-of-plane vibrations that, in the long-wave limit, behaves as ρ ω2=σ k2+κ k4 . The fluctuation tension σ is finite (˜0.1 N/m) even when the external mechanical tension vanishes. Transverse vibrations imply a duplicity in the definition of the elastic constants of the layer, as observables related to the real area of the surface may differ from those related to the in-plane projected area. This duplicity explains the variability of experimental data on the Young modulus of graphene based on electron spectroscopy, interferometric profilometry, and indentation experiments.

  6. Tension Stiffened and Tendon Actuated Manipulator

    Science.gov (United States)

    Doggett, William R. (Inventor); Dorsey, John T. (Inventor); Ganoe, George G. (Inventor); King, Bruce D. (Inventor); Jones, Thomas C. (Inventor); Mercer, Charles D. (Inventor); Corbin, Cole K. (Inventor)

    2015-01-01

    A tension stiffened and tendon actuated manipulator is provided performing robotic-like movements when acquiring a payload. The manipulator design can be adapted for use in-space, lunar or other planetary installations as it is readily configurable for acquiring and precisely manipulating a payload in both a zero-g environment and in an environment with a gravity field. The manipulator includes a plurality of link arms, a hinge connecting adjacent link arms together to allow the adjacent link arms to rotate relative to each other and a cable actuation and tensioning system provided between adjacent link arms. The cable actuation and tensioning system includes a spreader arm and a plurality of driven and non-driven elements attached to the link arms and the spreader arm. At least one cable is routed around the driven and non-driven elements for actuating the hinge.

  7. Cosmological Spacetimes from Negative Tension Brane Backgrounds

    CERN Document Server

    Burgess, C P; Rey, S J; Tasinato, G

    2002-01-01

    We put forward a viable nonsingular cosmology emerging out of negative-tension branes. The cosmology is based on a general class of solutions in Einstein-dilaton-Maxwell theory, presented in {\\tt hep-th/0106120}. We argue that solutions with hyperbolic or planar symmetry describe gravitational interactions due to a pair of negative-tension $q$-branes. These spacetimes are static near each brane, but become time-dependent and expanding at late times -- in some cases asymptotically approaching flat space. We interpret this expansion as being the spacetime's response to the branes presence. The time-dependent regions provide explicit realizations of cosmological spacetimes having past horizons without naked past singularities, and the past horizons are reminiscent of the S-brane solutions. We prove that the singularities in the static regions are repulsive to timelike geodesics, extract a cosmological `bounce' interpretation, compute the explicit charge and tension of the branes, analyse the classical stability ...

  8. Statistical Mechanics of Multilayer Sorption: Surface Tension.

    Science.gov (United States)

    Wexler, Anthony S; Dutcher, Cari S

    2013-05-16

    Mathematical models of surface tension as a function of solute concentration are needed for predicting the behavior of surface processes relevant to the environment, biology, and industry. Current aqueous surface tension-activity models capture either solutions of electrolytes or those of nonelectrolytes, but a single equation has not yet been found that represents both over the full range of compositions. In prior work, we developed an accurate model of the activity-concentration relationship in solutions over the full range of compositions by extending the BET (Brunauer, Emmett, Teller) and GAB (Guggenheim, Anderson, de Boer) isotherms to multiple monolayers of solvent molecules sorbed to solutes. Here, we employ similar statistical mechanical tools to develop a simple equation for the surface tension-activity relationship that differs remarkably from prior formulations in that it (1) works equally well for nonelectrolyte and electrolyte solutes and (2) is accurate over the full range of concentrations from pure solvent to pure solute.

  9. Surface tension effects in breaking wave noise.

    Science.gov (United States)

    Deane, Grant B

    2012-08-01

    The role of surface active materials in the sea surface microlayer on the production of underwater noise by breaking waves is considered. Wave noise is assumed to be generated by bubbles formed within actively breaking whitecaps, driven into breathing mode oscillation at the moment of their formation by non-equilibrium, surface tension forces. Two significant effects associated with surface tension are identified-a reduction in low frequency noise (bubbles by fluid turbulence within the whitecap and a reduction in overall noise level due to a decrease in the excitation amplitude of bubbles associated with reduced surface tension. The impact of the latter effect on the accuracy of Weather Observations Through Ambient Noise estimates of wind speed is assessed and generally found to be less than ±1 m s(-1) for wind speeds less than 10 m s(-1) and typical values of surfactant film pressure within sea slicks.

  10. Fatigue In Tension Perpendicular to the Grain

    DEFF Research Database (Denmark)

    Clorius, Christian Odin; Pedersen, Martin Uhre; Hoffmeyer, Preben;

    2004-01-01

    mechanism and a mechanism connected to damage introduced in the loading sequences. The purpose of the present study is to disentangle the effect of duration of load from the effect of load oscillation in fatigue in tension perpendicular to the grain. Fatigue experiments are made on small specimens...... and on dowel type joints with slotted in steel plates. In series of ten, the small specimens are taken to fatigue failure in uniform tension at square wave shaped load cycles at 0.01 Hz and 0.1 Hz. In arder to test the predictive validity of the result from the small tension specimens, fatigue experiments......Traditionally fatigue resistance is quantified as number of cycles to failure at a given stress level. A previous study by the authors showed that fatigue in compression parallel to the grain is governed partly by duration of load and partly by an effect of loading, i.e. a combination of a creep...

  11. Fatigue in tension perpendicular to the grain

    DEFF Research Database (Denmark)

    Clorius, Christian Odin; Pedersen, Martin Bo Uhre; Hoffmeyer, Preben;

    1999-01-01

    mechanism and a mechanism connected to damage introduce in the loading sequences. The purpose of the present study is to disentangle the effect of duration of load from the effect of load oscillation in fatigue in tension perpendicular to the grain. Fatigue experiments are made on small specimens...... and on dowel type joints with slotted in steel plates. In series of ten, the small specimens are taken to fatigue failure in uniform tension at square wave shaped load cycles at 0.01 Hz and 0.1 Hz. In order to test the predictive validity of the result from the small tension specimens, fatigue experiments......Traditinally fatigue resistance is quantified as number of cycles to failure at a given stress level. A previous study by the authors showed that fatigue in compression parallel to the grain is governed partly by duration of load and partly by an effect of loading, i.e. a combination of a creep...

  12. Experimental study of free abrasive wire sawing by using multi-strands wire

    Institute of Scientific and Technical Information of China (English)

    Yao Chunyan; Wang Jinsheng; Peng Wei; Jin Xin; Chen Shijie

    2013-01-01

    Grains in the slurry can be brought into cutting zone by steel wire with a certain speed to achieve the purpose of removing the workpiece material in the free abrasive wire sawing machining. Because its own of multi-strands characteristics,we use it to replace the steel wire to do slicing experiment. In this paper,multi-strands wire is made by seven metal wires and has many grooves on its surface. Compared with steel wire,it can carry more grains into cutting zone which is conducive to improving the slicing efficiency. We do some comparative slic-ing experiments by applying multi-strands wire (ϕ0.25 mm) and steel wire (ϕ0.25 mm) to cut optical glass (K9). The results show that slicing efficiency and the surface roughness of the workpiece sliced by using multi-strands wire are better than that by using steel wire,but the kerf width of the former is wider than that of the latter in the same experimental conditions.

  13. Surface-tension properties of hyaluronic Acid.

    Science.gov (United States)

    Knepper, P A; Covici, S; Fadel, J R; Mayanil, C S; Ritch, R

    1995-06-01

    The maintenance of flow channels in the trabecular meshwork is dependent, in part, on the patency of the trabecular spaces. Because the amount of hyaluronic acid decreases in the trabecular meshwork of patients with primary open-angle glaucoma, a change in surface tension may be one of the effects of hyaluronic acid on aqueous outflow. The surface-active properties of hyaluronic acid (concentration of 0.156-2.5 mg/ml; molecular weights of 100,000, 500,000, and 4,000,000) in deionized water, Ringer's lactate, Ringer's lactate plus 0.06 mg/ml bovine serum albumin, and mock aqueous solution were tested using the drop volume method. At a hyaluronic acid concentration of 0.312 mg/ml, surface tension decreased; at higher concentrations, a further decrease in surface tension was observed. In the presence of Ringer's lactate, the 100,000-MW hyaluronic acid was more active than the 4,000,000-MW hyaluronic acid. In the presence of Ringer's lactate plus bovine serum albumin or mock aqueous solution, the influence of surface tension of the 100,000-MW hyaluronic acid was moderated: with lower hyaluronic acid concentrations, the decline in surface tension was more than with Ringer's lactate, but with higher hyaluronic acid concentrations, the decline in surface tension was less than with Ringer's lactate. At high concentration, hyaluronic acid behaves like a non-Newtonian fluid, becomes more viscous, and may act to "seal" the trabecular space. The results of this study indicate that hyaluronic acid possesses surface-active properties, which is just one of several properties of hyaluronic acid that may influence aqueous outflow resistance.

  14. Wire recycling for quantum circuit optimization

    Science.gov (United States)

    Paler, Alexandru; Wille, Robert; Devitt, Simon J.

    2016-10-01

    Quantum information processing is expressed using quantum bits (qubits) and quantum gates which are arranged in terms of quantum circuits. Here, each qubit is associated with a quantum circuit wire which is used to conduct the desired operations. Most of the existing quantum circuits allocate a single quantum circuit wire for each qubit and hence introduce significant overhead. In fact, qubits are usually not needed during the entire computation, only between their initialization and measurement. Before and after that, corresponding wires may be used by other qubits. In this work, we propose a solution which exploits this fact in order to optimize the design of quantum circuits with respect to the required wires. To this end, we introduce a representation of the lifetimes of all qubits which is used to analyze the respective need for wires. Based on this analysis, a method is proposed which "recycles" the available wires and, as a result, reduces the size of the resulting circuit. Numerical tests based on established reversible and fault-tolerant quantum circuits confirm that the proposed solution reduces the number of wires by more than 90% compared to unoptimized quantum circuits.

  15. Students' difficulties with tension in massless strings

    Science.gov (United States)

    Flores-García, S.; Alfaro-Avena, L. L.; Chávez-Pierce, J. E.; Luna-González, J.; González-Quezada, M. D.

    2010-12-01

    Many students enrolled in introductory mechanics courses have difficulties with understanding the concept of static equilibrium. Some of these difficulties are related to the concept of force in the context of tension in massless strings. We identify three kinds of misconceptions: Students' beliefs that the angle of the string and proximity to the object are related to the tension. Students also use incorrect compensation arguments to reason about situations where both the angle and proximity change simultaneously. These difficulties were identified during investigations conducted in laboratory and lecture sessions at three universities in the United States and Mexico.

  16. Space Station Freedom secondary power wiring requirements

    Science.gov (United States)

    Sawyer, C. R.

    1994-09-01

    Secondary power is produced by DDCU's (direct current to direct current converter units) and routed to and through secondary power distribution assemblies (SPDA's) to loads or tertiary distribution assemblies. This presentation outlines requirements of Space Station Freedom (SSF) EEE (electrical, electronic, and electromechanical) parts wire and the approved electrical wire and cable. The SSF PDRD (Program Definition and Requirements Document) language problems and resolution are reviewed. The cable routing to and from the SPDA's is presented as diagrams and the wire recommendations and characteristics are given.

  17. Electro-mechanical characterization of MgB2 wires for the Superconducting Link Project at CERN

    Science.gov (United States)

    Konstantopoulou, K.; Ballarino, A.; Gharib, A.; Stimac, A.; Garcia Gonzalez, M.; Perez Fontenla, A. T.; Sugano, M.

    2016-08-01

    In previous years, the R & D program between CERN and Columbus Superconductors SpA led to the development of several configurations of MgB2 wires. The aim was to achieve excellent superconducting properties in high-current MgB2 cables for the HL-LHC upgrade. In addition to good electrical performance, the superconductor shall have good mechanical strength in view of the stresses during operation (Lorenz forces and thermal contraction) and handling (tension and bending) during cabling and installation at room temperature. Thus, the study of the mechanical properties of MgB2 wires is crucial for the cable design and its functional use. In the present work we report on the electro-mechanical characterization of ex situ processed composite MgB2 wires. Tensile tests (critical current versus strain) were carried out at 4.2 K and in a 3 T external field by means of a purpose-built bespoke device to determine the irreversible strain limit of the wire. The minimum bending radius of the wire was calculated taking into account the dependence of the critical current with the strain and it was then used to obtain the minimum twist pitch of MgB2 wires in the cable. Strands extracted from cables having different configurations were tested to quantify the critical current degradation. The Young’s modulus of the composite wire was measured at room temperature. Finally, all measured mechanical parameters will be used to optimize an 18-strand MgB2 cable configuration.

  18. Processing, Structural Characterization and Comparative Studies on Uniaxial Tensile Properties of a New Type of Porous Twisted Wire Material

    Directory of Open Access Journals (Sweden)

    Fei Wu

    2015-08-01

    Full Text Available A self-developed rotary multi-cutter device cuts stainless steel wire ropes into segments to fabricate twisted wires. Stainless steel porous twisted wire materials (PTWMs with a spatial composite intertexture structure are produced by the compaction and subsequent vacuum solid-phase sintering of twisted wires. The stainless steel PTWMs show two types of typical uniaxial tensile failure modes, i.e., a 45° angle fracture mode and an auxetic failure mode (the PTWMs expand along the direction perpendicular to the tension. The effects of the sintering parameters, porosities, wire diameters, and sampling direction on the tensile properties of the PTWMs are carefully investigated. By increasing the sintering temperature from 1130 °C to 1330 °C, the tensile strength of the PTWMs with 70% target porosity increased from 7.7 MPa to 28.6 MPa and the total failure goes down to 50%. When increasing the sintering time from 90 min to 150 min, the tensile strength increases from 12.4 MPa to 19.1 MPa and the total failure elongation drops to 78.6%. The tensile strength of the PTWMs increases from 28.9 MPa to 112.7 MPa with decreasing porosity from 69.5% to 46.0%, and the total failure elongation also increases from 14.8% to 40.7%. The tensile strength and the failure strain of the PTWMs with fine wires are higher than those of the PTWMs with coarse wires under the same porosity. Sampling direction has a small influence on the tensile properties of the PTWMs.

  19. Worldsheet electromagnetism and the superstring tension

    Energy Technology Data Exchange (ETDEWEB)

    Townsend, P.K. (DAMTP, Univ. Cambridge (United Kingdom))

    1992-03-05

    A superstring action, invariant under the symmetries corresponding to a free differential N=1 superalgebra, is constructed. Its worldsheet fields include an electromagnetic gauge potential. Its equations of motion are those of the Green-Schwarz superstring but with the string tension given by the circulation of the worldsheet electric field around the string. (orig.).

  20. Tension Tests On Bored Piles In Sand

    DEFF Research Database (Denmark)

    Krabbenhøft, Sven; Clausen, Johan; Damkilde, Lars

    2006-01-01

    The lengths of the bored piles varied from 2 m to 6 m and all were of a diameter of 140 mm. The piles were tested to failure in tension and the load-displacement relations were recorded. The investigation has shown pronounced differences between the load bearing capacities obtained by different...

  1. Surface tension of evaporating nanofluid droplets

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Ruey-Hung [Univ. of Central Florida, Orlando, FL (United States); Phuoc, Tran X. [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Martello, Donald [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States)

    2011-05-01

    Measurements of nanofluid surface tension were made using the pendant droplet method. Three different types of nanoparticles were used - laponite, silver and Fe2O3 - with de-ionized water (DW) as the base fluid. The reported results focus on the following categories; (1) because some nanoparticles require surfactants to form stable colloids, the individual effects of the surfactant and the particles were investigated; (2) due to evaporation of the pendant droplet, the particle concentration increases, affecting the apparent surface tension; (3) because of the evaporation process, a hysteresis was found where the evaporating droplet can only achieve lower values of surface tension than that of nanofluids at the same prepared concentrations: and (4) the Stefan equation relating the apparent surface tension and heat of evaporation was found to be inapplicable for nanofluids investigated. Comparisons with findings for sessile droplets are also discussed, pointing to additional effects of nanoparticles other than the non-equilibrium evaporation process.

  2. Tension in Chemistry and Its Contents

    Science.gov (United States)

    Hoffmann, Roald

    2015-01-01

    This article makes a case for a positive role of tension in the creative process in chemistry. I begin with an argument that there is an inherent tension in what makes molecules interesting—their positioning along various polar axes. One of these, the age-old differentiation between useful (to society and for personal profit) commercialization and pure understanding of molecules and their reactions is characteristic. The question of whether there are any bad molecules then leads me to ethical concerns in chemistry, and a particular working out of these in interactions of chemists in the Middle East. An analysis is made of the special tensions involved in publishing, especially in citation ethics; chemists publish a lot, so this is situation ethics worked out on a daily basis. I then find in the literature of psychology good evidence for the positive value of moderate stress in stimulating creativity. It is obvious that too much tension leads to distress, and there are some institutional aspects of chemistry that do not come out well here. But all in all, the dynamic middle is alive, and it leads to good new science. PMID:26155730

  3. Regulation of Cellular Tension in Adherent Cells

    Science.gov (United States)

    Oakes, Patrick

    2013-03-01

    Cells generate stress on their surrounding extracellular matrix (ECM) via myosin II motor generated forces which are transmitted through the actin cytoskeleton. The mechanisms in the cell which regulate the magnitude and spatial distribution of these stresses, however, remain unknown. Consistent with previous reports, we find that the total magnitude of traction force exerted on the ECM scales with cell size. Such scaling is observed across numerous cell types and reflects an inherent cellular tension determined by the level of myosin II activity. Surprisingly, while stiffness modulates the cellular spread area, we find this scaling relationship to be independent of ECM stiffness. To identify the biophysical mechanisms regulating the generation of tension, we utilize micro-patterning to isolate cell spread area from cell geometry and to spatially control the distribution of stress on the ECM. We find that traction stress magnitude is dependent on the local curvature of the cell. Changes in cell geometry result in a redistribution of local stresses, but little change in the total stress applied to the ECM. Finally, for a constant geometry, we find that both the total stress and the average stress exerted on the ECM increase with cell area. Together these data suggest that the cell can be modeled as a uniformly contracting mesh, where the magnitude of tension is regulated by the cell spread area, and the distribution of tension is regulated by local geometry.

  4. Study of branes with variable tension

    CERN Document Server

    Aros, Rodrigo

    2016-01-01

    In this work we study a brane world model with variable tension which gives rise to four dimensional cosmologies. The brane worlds obtained correspond to E\\"{o}tv\\"{o}s branes whose (internal) geometry can be casted as either a four dimensional (A)dS$_{4}$ or a standard radiation period cosmology. The matter dominated period is discussed as well.

  5. Normal tension glaucoma and Alzheimer disease

    DEFF Research Database (Denmark)

    Bach-Holm, Daniella; Kessing, Svend Vedel; Mogensen, Ulla

    2012-01-01

    PURPOSE: To investigate whether normal tension glaucoma (NTG) is associated with increased risk of developing dementia/Alzheimer disease (AD). METHODS: A total of 69 patients with NTG were identified in the case note files in the Glaucoma Clinic, University Hospital of Copenhagen (Rigshospitalet...

  6. Tension in Chemistry and Its Contents.

    Science.gov (United States)

    Hoffmann, Roald

    2015-01-01

    This article makes a case for a positive role of tension in the creative process in chemistry. I begin with an argument that there is an inherent tension in what makes molecules interesting--their positioning along various polar axes. One of these, the age-old differentiation between useful (to society and for personal profit) commercialization and pure understanding of molecules and their reactions is characteristic. The question of whether there are any bad molecules then leads me to ethical concerns in chemistry, and a particular working out of these in interactions of chemists in the Middle East. An analysis is made of the special tensions involved in publishing, especially in citation ethics; chemists publish a lot, so this is situation ethics worked out on a daily basis. I then find in the literature of psychology good evidence for the positive value of moderate stress in stimulating creativity. It is obvious that too much tension leads to distress, and there are some institutional aspects of chemistry that do not come out well here. But all in all, the dynamic middle is alive, and it leads to good new science.

  7. Inclusion and Participation: Working with the Tensions

    Directory of Open Access Journals (Sweden)

    Gideon Calder

    2011-12-01

    Full Text Available Democracy is crucially about inclusion: a theory of democracy must account for who is to be included in the democratic process, how, and on what terms. Inclusion, if conceived democratically, is fraught with tensions. This article identifies three such tensions, arising respectively in: (i the inauguration of the democratic public; (ii enabling equal participation; and (iii the relationship between instrumental and non-instrumental accounts of democracy’s value. In each case, I argue, rather than seeking somehow to dissolve or avoid such tensions, theories of democracy should allow us to live with their implications reflexively: to work with them. Such tensions are counter-democratic to the extent that they derail what Nancy Fraser calls “participatory parity,” under which citizens count as “full partners in social interaction.” But the extent to which they do this is not itself dependent on points of paradox in the very idea of inclusion. Such parity relies on complex factors, social and economic, which democratic institutions and procedures will not by themselves address. To achieve full democratic inclusion we must already have addressed such factors; no account of democracy itself, however finely-tuned, will do this.

  8. Dynamic Surface Tensions of Fluorous Surfactant Solutions

    Institute of Scientific and Technical Information of China (English)

    高艳安; 侯万国; 王仲妮; 李干佐; 韩布兴; 张高勇; 吕锋锋

    2005-01-01

    Dynamic surface properties of aqueous solutions of cationic fluorous surfactant CF3CF2CF20(CF(CF3)CF2O)2CF(CF3)CONH(CHE)3N+(C2H5)2CH3I- (abbrev. FC-4 ) were reported. The critical micelle concentration (cmc)(3.6×10-5 mol/L) and equilibdum surface tensions γeq were measured by Krtlss K12 tension apparatus. Dynamic surface tension γ(t) was measured in the range of 15 ms to 200 s using the MBP tensiometer. The surface excess Γ,as a function of concentration, was obtained from equilibrium tensiometry using the Gibbs equation. Data from these experiments were combined to analyze the γ(t) decays according to the asymptotic Ward and Tordai equation.The results show that at the initial adsorption stage, the dynamic surface tension data were all consistent with this diffusion-controlled mechanism, and at the end of the adsorption process, there were some evidences for an adsorption barrier, suggesting a mixed diffusion-controlled adsorption mechanism. Using measured quantities, the barrier strength was estimated as between 25 and 35 kJ/mol at 25℃. The surface pressure plays an important role in contributing to the barrier.

  9. Tension and relaxation in the individual.

    Science.gov (United States)

    Newbury, C R

    1979-06-01

    Increasing materialism in society is resulting in more wide spread nervous tension in all age groups. While some degree of nervous tension is necessary in everyday living, its adverse effects require that we must learn to bring it under control. Total tension is shown to have two components: a controllable element arising from factors in the environment and the inbuilt uncontrollable residue which is basic in the individual temperament. The effects of excessive or uncontrolled stress can be classified as 1) emotional reactions such as neurotic behaviour (anxiety hypochondria, hysteria, phobia, depression obsessions and compulsions) or psychotic behaviour and 2) psychosomatic reactions (nervous asthma, headache, insomnia, heart attack). Nervous energy can be wastefully expended by such factors as loss of temper, wrong attitudes to work, job frustration and marital strains. Relaxation is the only positive way to control undesirable nervous tension and its techniques require to be learned. A number of techniques (progressive relaxation, differential relaxation, hypnosis, the use of biofeedback, Yoga and Transcendental Meditation) are described and their application to dental practice is discussed.

  10. 7 CFR 1755.506 - Aerial wire services

    Science.gov (United States)

    2010-01-01

    ...), Specifications and Drawings for Service Installations at Customer Access Locations. The wire used for aerial... service wire spans. (d) Aerial service wires shall be run in accordance with the construction drawings... aerial service wires at poles shall be as illustrated in construction drawings 503-2 and 504 contained in...

  11. Diamagnetism in wire medium metamaterials: theory and experiment

    CERN Document Server

    Yagupov, Ilya; Kosulnikov, Sergei; Hasan, Mehedi; Iorsh, Ivan; Belov, Pavel

    2015-01-01

    Strong diamagnetic response of wire medium with finite wire radius is reported. Contrary to the previous works where it was assumed that the wire medium exhibits only the electric response, we show that the non-zero magnetic susceptibility has to be taken into account for proper effective medium description of the wire medium. Analytical and numerical results are supported by the experimental measurements.

  12. Modelling aluminium wire bond reliability in high power OMP devices

    NARCIS (Netherlands)

    Kregting, R.; Yuan, C.A.; Xiao, A.; Bruijn, F. de

    2011-01-01

    In a RF power application such as the OMP, the wires are subjected to high current (because of the high power) and high temperature (because of the heat from IC and joule-heating from the wire itself). Moreover, the wire shape is essential to the RF performance. Hence, the aluminium wire is preferre

  13. 47 CFR 76.804 - Disposition of home run wiring.

    Science.gov (United States)

    2010-10-01

    ... in service to subscribers to the extent possible. (b) Unit-by-unit disposition of home run wiring: (1... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of home run wiring. 76.804 Section... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.804 Disposition of home run wiring....

  14. 30 CFR 56.12053 - Circuits powered from trolley wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Circuits powered from trolley wires. 56.12053... § 56.12053 Circuits powered from trolley wires. Ground wires for lighting circuits powered from trolley wires shall be connected securely to the ground-return circuit....

  15. 30 CFR 57.12053 - Circuits powered from trolley wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Circuits powered from trolley wires. 57.12053... Electricity Surface and Underground § 57.12053 Circuits powered from trolley wires. Ground wires for lighting circuits powered from trolley wires shall be connected securely to the ground return circuit. Surface Only...

  16. Tunable permeability of magnetic wires at microwaves

    Science.gov (United States)

    Panina, L. V.; Makhnovskiy, D. P.; Morchenko, A. T.; Kostishin, V. G.

    2015-06-01

    This paper presents the analysis into microwave magnetic properties of magnetic microwires and their composites in the context of applications in wireless sensors and tunable microwave materials. It is demonstrated that the intrinsic permeability of wires has a wide frequency dispersion with relatively large values in the GHz band. In the case of a specific magnetic anisotropy this results in a tunable microwave impedance which could be used for distributed wireless sensing networks in functional composites. The other range of applications is related with developing the artificial magnetic dielectrics with large and tunable permeability. The composites with magnetic wires with a circumferential anisotropy have the effective permeability which differs substantially from unity for a relatively low concentration (less than 10%). This can make it possible to design the wire media with a negative and tunable index of refraction utilising natural magnetic properties of wires.

  17. 30 CFR 56.12047 - Guy wires.

    Science.gov (United States)

    2010-07-01

    ... wires of poles supporting high-voltage transmission lines shall meet the requirements for grounding or... Installation and Maintenance of Electric Supply and Communication Lines” (also referred to as National...

  18. Inelastic Electron Transport in Monoatomic Wires

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jin; CHEN Jing-Zhe; CHEN Qing; REN Shang-Fen; HAN Ru-Shan

    2007-01-01

    @@ Based on non-equilibrium Green's function theory and density functional theory, we investigate the vibrational property and electron-phonon (el-ph) interaction induced inelastic scattering in electron transport through metallic monoatomic wires.

  19. Wire Bonder: Kulicke and Soffa Model 4526

    Data.gov (United States)

    Federal Laboratory Consortium — Description:CORAL Name: Wire BonderNeeds Description.Scientific Opportunities / Applications:Wedge bonderSemi-automatic and manual modesIndependent Z-axis control,...

  20. Beam Profiling through Wire Chambing Tracking

    CERN Document Server

    Nash, W

    2013-01-01

    This note describes the calibration of the Delay Wire Chambers (DWCs) used during test runs of CALICE’s Tungsten Digital Hadron Calorimeter (W-DHCAL) prototype in CERN’s SPS beam line (10 – 300 GeV).

  1. Wire core reactor for nuclear thermal propulsion

    Science.gov (United States)

    Harty, Richard B.; Brengle, Robert G.

    1993-01-01

    Studies have been performed of a compact high-performance nuclear rocket reactor that incorporates a tungsten alloy wire fuel element. This reactor, termed the wire core reactor, can deliver a specific impulse of 1,000 s using an expander cycle and a nozzle expansion ratio of 500 to 1. The core is constructed of layers of 0.8-mm-dia fueled tungsten wires wound over alternate layers of spacer wires, which forms a rugged annular lattice. Hydrogen flow in the core is annular, flowing from inside to outside. In addition to the concepts compact size and good heat transfer, the core has excellent power-flow matching features and can resist vibration and thermal stresses during star-up and shutdown.

  2. Highly stretchable wrinkled gold thin film wires

    Science.gov (United States)

    Kim, Joshua; Park, Sun-Jun; Nguyen, Thao; Chu, Michael; Pegan, Jonathan D.; Khine, Michelle

    2016-02-01

    With the growing prominence of wearable electronic technology, there is a need to improve the mechanical reliability of electronics for more demanding applications. Conductive wires represent a vital component present in all electronics. Unlike traditional planar and rigid electronics, these new wearable electrical components must conform to curvilinear surfaces, stretch with the body, and remain unobtrusive and low profile. In this paper, the piezoresistive response of shrink induced wrinkled gold thin films under strain demonstrates robust conductive performance in excess of 200% strain. Importantly, the wrinkled metallic thin films displayed negligible change in resistance of up to 100% strain. The wrinkled metallic wires exhibited consistent performance after repetitive strain. Importantly, these wrinkled thin films are inexpensive to fabricate and are compatible with roll to roll manufacturing processes. We propose that these wrinkled metal thin film wires are an attractive alternative to conventional wires for wearable applications.

  3. Angular response of hot wire probes

    Science.gov (United States)

    di Mare, L.; Jelly, T. O.; Day, I. J.

    2017-03-01

    A new equation for the convective heat loss from the sensor of a hot-wire probe is derived which accounts for both the potential and the viscous parts of the flow past the prongs. The convective heat loss from the sensor is related to the far-field velocity by an expression containing a term representing the potential flow around the prongs, and a term representing their viscous effect. This latter term is absent in the response equations available in the literature but is essential in representing some features of the observed response of miniature hot-wire probes. The response equation contains only four parameters but it can reproduce, with great accuracy, the behaviour of commonly used single-wire probes. The response equation simplifies the calibration the angular response of rotated slanted hot-wire probes: only standard King’s law parameters and a Reynolds-dependent drag coefficient need to be determined.

  4. Frequency Responses Of Hot-Wire Anemometers

    Science.gov (United States)

    Watmuff, Jonathan H.

    1992-01-01

    Report describes theoretical study of frequency response of constant-temperature hot-wire anemometer, with view toward increasing frequency response while maintaining stable operation in supersonic flow. Effects of various circuit parameters discussed.

  5. Highly stretchable wrinkled gold thin film wires

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joshua, E-mail: joshuk7@uci.edu; Park, Sun-Jun; Nguyen, Thao [Department of Chemical Engineering and Materials Science, University of California, Irvine, California 92697 (United States); Chu, Michael [Department of Biomedical Engineering, University of California, Irvine, California 92697 (United States); Pegan, Jonathan D. [Department of Materials and Manufacturing Technology, University of California, Irvine, California 92697 (United States); Khine, Michelle, E-mail: mkhine@uci.edu [Department of Chemical Engineering and Materials Science, University of California, Irvine, California 92697 (United States); Department of Biomedical Engineering, University of California, Irvine, California 92697 (United States)

    2016-02-08

    With the growing prominence of wearable electronic technology, there is a need to improve the mechanical reliability of electronics for more demanding applications. Conductive wires represent a vital component present in all electronics. Unlike traditional planar and rigid electronics, these new wearable electrical components must conform to curvilinear surfaces, stretch with the body, and remain unobtrusive and low profile. In this paper, the piezoresistive response of shrink induced wrinkled gold thin films under strain demonstrates robust conductive performance in excess of 200% strain. Importantly, the wrinkled metallic thin films displayed negligible change in resistance of up to 100% strain. The wrinkled metallic wires exhibited consistent performance after repetitive strain. Importantly, these wrinkled thin films are inexpensive to fabricate and are compatible with roll to roll manufacturing processes. We propose that these wrinkled metal thin film wires are an attractive alternative to conventional wires for wearable applications.

  6. Refractometric sensor based on silicon photonic wires

    OpenAIRE

    2009-01-01

    We have characterized the refractive index sensing properties of a compact refractometric sensor based on a grated silicon photonic wire. A resolution of $10^{-5}$ in refractive index has been measured.

  7. Audio wiring guide how to wire the most popular audio and video connectors

    CERN Document Server

    Hechtman, John

    2012-01-01

    Whether you're a pro or an amateur, a musician or into multimedia, you can't afford to guess about audio wiring. The Audio Wiring Guide is a comprehensive, easy-to-use guide that explains exactly what you need to know. No matter the size of your wiring project or installation, this handy tool provides you with the essential information you need and the techniques to use it. Using The Audio Wiring Guide is like having an expert at your side. By following the clear, step-by-step directions, you can do professional-level work at a fraction of the cost.

  8. Coating of a steel wire with copper

    Science.gov (United States)

    Vdovin, K. N.; Dubskii, G. A.; Nefed'ev, A. A.; Derevyanko, D. V.

    2016-03-01

    The process of coating of a steel wire with liquid copper at a high speed (>1 m/s) is considered. The results of long-term studies of copperizing under laboratory conditions and electron-microscopic investigation of the copper-steel adhesion are used to develop a mathematical model for coating of a steel wire with copper and to create a commercial setup to implement this process.

  9. Graphene wire medium: Homogenization and application

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Chigrin, Dmitry N.; Lavrinenko, Andrei

    2012-01-01

    In this contribution we analyze numerically the optical properties of the graphene wire medium, which unit cell consists of a stripe of graphene embedded into dielectric. We propose a simple method for retrieval of the isofrequency contour and effective permittivity tensor. As an example...... of the graphene wire medium application we demonstrate a reconfigurable hyperlens for the terahertz subwavelength imaging capable of resolving two sources with separation λ0/5 in the far-field....

  10. A Magnetic Sensor with Amorphous Wire

    Directory of Open Access Journals (Sweden)

    Dongfeng He

    2014-06-01

    Full Text Available Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz. To show the sensitivity and the spatial resolution, the magnetic field of a thousand Japanese yen was scanned with the magnetic sensor.

  11. Note: Improved wire-wound heater.

    Science.gov (United States)

    Steinmann, Ricardo G; Vitoux, Hugo

    2015-01-01

    The authors have measured, at cryogenic temperature, the upper limit of the heat transfer in different configurations of a wire-wound heater. We found that the heat transferred has an upper limit of about 15 W/cm(2) and is dependent on the diameter of the wire. In this paper, we present three ways of increasing the heat transferred by this type of heater and its application in different continuous flow cryostats.

  12. Note: Improved wire-wound heater

    Science.gov (United States)

    Steinmann, Ricardo G.; Vitoux, Hugo

    2015-01-01

    The authors have measured, at cryogenic temperature, the upper limit of the heat transfer in different configurations of a wire-wound heater. We found that the heat transferred has an upper limit of about 15 W/cm2 and is dependent on the diameter of the wire. In this paper, we present three ways of increasing the heat transferred by this type of heater and its application in different continuous flow cryostats.

  13. Tracking with wire chambers at high luminosities

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, G.G. (Indiana Univ., Bloomington, IN (USA) Stanford Linear Accelerator Center, Menlo Park, CA (USA))

    1989-12-01

    Radiation damage and rate limitations impose severe constraints on wire chambers at the SSC. Possible conceptual designs for wire chamber tracking systems that satisfy these constraints are discussed. Computer simulation studies of tracking in such systems are presented. Simulations of events from interesting physics at the SSC, including hits from minimum bias background events, are examined. Results of some preliminary pattern recognition studies are given. 11 refs., 10 figs.

  14. Corrosion of surface defects in fine wires.

    Science.gov (United States)

    Rentler, R M; Greene, N D

    1975-11-01

    Defects were observed on the surfaces of various fine diameter wires commonly used in biomedical applications. These surface irregularities were viewed at high magnifications using a scanning electron microscope which has a much greater depth of field than normal light microscopy. Defects include scratches, pits, and crevices, which are the result of commercial wire drawing practices. Corrosion test results show that imperfections can serve as sites for localized corrosion attack which could lead to premature failures.

  15. Novel use of the "buddy"wire.

    LENUS (Irish Health Repository)

    O'Hare, A

    2008-12-29

    Summary: During interventional procedures the tortuosity of the vasculature hampers catheter stability. The buddy wire may be used to aid and maintain vascular access.We describe a case of acute subarachnoid haemorrhage secondary to dissecting aneurysm of the vertebral artery.We discuss the value of the buddy wire during balloon occlusion of the vertebral artery not as it is typically used, but to actually prevent the balloon repeatedly entering the posterior inferior cerebellar artery during the procedure.

  16. A Magnetic Sensor with Amorphous Wire

    OpenAIRE

    Dongfeng He; Mitsuharu Shiwa

    2014-01-01

    Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz. To show the sensitivity and the spatial resolution, the magnetic field of a thousand Japanese yen was scanned with the magnetic sensor.

  17. Effect of surface tension on self-termination in Au tip fabrication for tip-enhanced Raman spectroscopy

    Science.gov (United States)

    Chaunchaiyakul, Songpol; Yano, Takeshi; Krukowski, Pawel; Kuwahara, Yuji

    2016-09-01

    The effect of surface tension on the fabrication of Au tips was investigated. When using a 12 M HCl aqueous solution, the etching process did not consistently self-terminate after the lower part of the wire dropped, resulting in the poor reproducibility of the tip sharpness. However, using an ethanolic solution of 12 mol/l HCl, a self-terminating etching process was always observed, resulting in the improved reproducibility of sharp tips. We attribute this to the reduced surface compared to that of aqueous HCl. The obtained tips were used in tip-enhanced Raman spectroscopy experiments, in which significant signal enhancement was observed.

  18. Chemistry of radiation damage to wire chambers

    Energy Technology Data Exchange (ETDEWEB)

    Wise, J.

    1992-08-01

    Proportional counters are used to study aspects of radiation damage to wire chambers (wire aging). Principles of low-pressure, rf plasma chemistry are used to predict the plasma chemistry in electron avalanches (1 atm, dc). (1) Aging is studied in CF{sub 4}/iC{sub 4}H{sub 10} gas mixtures. Wire deposits are analyzed by Auger electron spectroscopy. An apparent cathode aging process resulting in loss of gain rather than in a self-sustained current is observed in CF{sub 4}-rich gases. A four-part model considering plasma polymerization of the hydrocarbon, etching of wire deposits by CF{sub 4}, acceleration of deposition processes in strongly etching environments, and reactivity of the wire surface is developed to understand anode wire aging in CF{sub 4}/iC{sub 4}H{sub 10} gases. Practical guidelines suggested by the model are discussed. (2) Data are presented to suggest that trace amounts of Freons do not affect aging rates in either dimethyl ether or Ar/C{sub 2}H{sub 6}. Apparent loss of gain is explained by attachment of primary electrons to a continuously increasing concentration of Freon 11 (CCl{sub 3}F) in the counter gas. An increase in the concentration of Freon 11 in dimethyl ether is caused by a distillation process in the gas supply bottle and is a natural consequence of the unequal volatilities of the two compounds.

  19. Needleless electrospinning with twisted wire spinneret.

    Science.gov (United States)

    Holopainen, Jani; Penttinen, Toni; Santala, Eero; Ritala, Mikko

    2015-01-16

    A needleless electrospinning setup named 'Needleless Twisted Wire Electrospinning' was developed. The polymer solution is electrospun from the surface of a twisted wire set to a high voltage and collected on a cylindrical collector around the wire. Multiple Taylor cones are simultaneously self-formed on the downward flowing solution. The system is robust and simple with no moving parts aside from the syringe pump used to transport the solution to the top of the wire. The structure and process parameters of the setup and the results on the preparation of polyvinyl pyrrolidone (PVP), hydroxyapatite (HA) and bioglass fibers with the setup are presented. PVP fiber sheets with areas of 40 × 120 cm(2) and masses up to 1.15 g were prepared. High production rates of 5.23 g h(-1) and 1.40 g h(-1) were achieved for PVP and HA respectively. The major limiting factor of the setup is drying of the polymer solution on the wire during the electrospinning process which will eventually force to interrupt the process for cleaning of the wire. Possible solutions to this problem and other ways to develop the setup are discussed. The presented system provides a simple way to increase the production rate and area of fiber sheet as compared with the conventional needle electrospinning.

  20. Subchannel Analysis of Wire Wrapped SCWR Assembly

    Directory of Open Access Journals (Sweden)

    Jianqiang Shan

    2014-01-01

    Full Text Available Application of wire wrap spacers in SCWR can reduce pressure drop and obtain better mixing capability. As a consequence, the required coolant pumping power is decreased and the coolant temperature profile inside the fuel bundle is flattened which will obviously decrease the peak cladding temperature. The distributed resistance model for wire wrap was developed and implemented in ATHAS subchannel analysis code. The HPLWR wire wrapped assembly was analyzed. The results show that: (1 the assembly with wire wrap can obtain a more uniform coolant temperature profile than the grid spaced assembly, which will result in a lower peak cladding temperature; (2 the pressure drop in a wire wrapped assembly is less than that in a grid spaced assembly, which can reduce the operating power of pump effectively; (3 the wire wrap pitch has significant effect on the flow in the assembly. Smaller Hwire/Drod will result in stronger cross flow a more uniform coolant temperature profile, and also a higher pressure drop.

  1. A Review of Temporary Cardiac Pacing Wires

    Directory of Open Access Journals (Sweden)

    2007-01-01

    Full Text Available Aims: This review aims to tabulate data from all available studies of temporary cardiac pacing wires. Particular aims were to determine the best route of venous access and find ways to reduce complications. The review set out to see if specialist doctors are better at inserting wires than non-specialist doctors. In addition, a contemporary study of wire insertion has been performed to compare modern practice in the UK with the previous studies.Methods: A literature search produced 15 studies available for inclusion. Over 3700 patients from 1973 to 2004 were included. The data was tabulated and attention was given to the route of venous access, the complication rates and whether a specialist or non-specialist doctor had inserted the wire. Results: Internal jugular veins are associated with lowest complication rates and ease of access. Antecubital fossa veins have the highest complication rates. Complication rates are high, especially infections and failure to secure access. Specialist doctors have lower rates of complications than non-specialist doctors. Elderly patient suffer the highest complication rate. Our study showed comparable results to the previous studies.Conclusions: Internal jugular veins are the preferred route for access followed by subclavian and femoral veins. The right side should be used when possible. The use of antibiotics and ultrasound probes must be contemplated for all wire insertions. Alternatives to wire insertion (especially in the elderly must be seriously considered. Setting up an on-call rota would provide experienced doctors to reduce complication rates.

  2. 75 FR 60480 - In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire...

    Science.gov (United States)

    2010-09-30

    ... COMMISSION In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire... importation, or the sale within the United States after importation of certain bulk welding wire containers, components thereof, and welding wire by reason of infringement of certain claims of United States Patent...

  3. Contractility studies on isolated bovine choroidal small arteries: determination of the active and passive wall tension-internal circumference relation.

    Science.gov (United States)

    Delaey, C; Boussery, K; Van de Voorde, J

    2002-09-01

    Studies on isolated choroidal arteries could help to understand the regulatory mechanisms in the choroidal circulation. The aim of the present study was therefore to assess whether contractility studies on isolated choroidal arteries were feasible and to determine the active and passive wall tension-internal circumference relation of these arteries. This relation is essential for reliable further pharmacodynamic studies on these vessels. Isolated choroidal arteries were mounted on a wire myograph for isometric tension recording. After the vessel was mounted, the L(100) (the circumference of the vessel at a transmural pressure of 100 mmHg) was determined. Then the passive and active wall tension-internal circumference relation of the choroidal vessels was obtained by stepwise increasing the internal circumference. The changes in the internal circumference were expressed as a percentage of L(100). After each increase in circumference, the passive tone (in a calcium free medium), the spontaneous tone (in a Krebs--Ringer bicarbonate solution) and the active tone (in a solution containing K(+) 120 mM and prostaglandin F(2 alpha) 30 microM) was measured. The passive tone of the vessel increased exponentially with the circumference of the vessel. Both the spontaneous tone and the active tone also increased when the vessel was stretched. They peaked when the internal circumference approached 90% of the L(100) and diminished again when the circumference was further increased. The peak value of the active tension curve averaged 2.24+/-0.47 Nm(-1) (n=10). The passive tension was 0.57+/-0.08 Nm(-1) (n=10) at this circumference. The peak value of the spontaneous tension curve averaged 0.37+/-0.08 Nm(-1) (n=10). It can be concluded that in vitro contractility studies on isolated choroidal arteries are feasible. The optimal length or preload of the choroidal arteries is attained when the internal circumference of the artery is set to 90% of the L(100).

  4. The Analysis of the High Speed Wire Drawing Process of High Carbon Steel Wires Under Hydrodynamic Lubrication Conditions

    Directory of Open Access Journals (Sweden)

    Suliga M.

    2015-04-01

    Full Text Available In this work the analysis of the wire drawing process in hydrodynamic dies has been done. The drawing process of φ5.5 mm wire rod to the final wire of φ1.7 mm was conducted in 12 passes, in drawing speed range of 5-25 m/s. For final wires of φ1.7 mm the investigation of topography of wire surface, the amount of lubricant on the wire surface and the pressure of lubricant in hydrodynamic dies were determined. Additionally, in the work selected mechanical properties of the wires have been estimated.

  5. The Analysis of the High Speed Wire Drawing Process of High Carbon Steel Wires Under Hydrodynamic Lubrication Conditions

    OpenAIRE

    Suliga M.

    2015-01-01

    In this work the analysis of the wire drawing process in hydrodynamic dies has been done. The drawing process of φ5.5 mm wire rod to the final wire of φ1.7 mm was conducted in 12 passes, in drawing speed range of 5-25 m/s. For final wires of φ1.7 mm the investigation of topography of wire surface, the amount of lubricant on the wire surface and the pressure of lubricant in hydrodynamic dies were determined. Additionally, in the work selected mechanical properties of the wires have been estima...

  6. A statistical approach to understand the role of inclusions on the fatigue resistance of superelastic Nitinol wire and tubing.

    Science.gov (United States)

    Robertson, Scott W; Launey, Maximilien; Shelley, Oren; Ong, Ich; Vien, Lot; Senthilnathan, Karthike; Saffari, Payman; Schlegel, Scott; Pelton, Alan R

    2015-11-01

    Superelastic wires and diamond-shaped stent surrogates were manufactured from Nitinol rods and tubing, respectively, from five different mill product suppliers - Standard VAR, Standard VIM, Standard VIM+VAR, Process-Optimized VIM+VAR, and High-Purity VAR. High-cycle fatigue tests up to 10(7) cycles were conducted under tension-tension conditions for wires and bending conditions for diamonds. These materials were compared under both testing methods at 37°C with 6% prestrain and 3% mean strain (unloading plateau) with a range of alternating strains. The High-Purity VAR material outperformed all alloys tested with a measured 10(7)-fatigue alternating strain limit of 0.32% for wire and 1.75% for diamonds. Process-Optimized VIM+VAR material was only slightly inferior to the High Purity VAR with a diamond alternating bending strain limit of 1.5%. These two "second generation" Nitinol alloys demonstrated approximately a 2× increase in 10(7)-cycle fatigue strain limit compared to all of the Standard-grade Nitinol alloys (VAR, VIM, and VIM+VAR) that demonstrated virtually indistinguishable fatigue performance. This statistically-significant increase in fatigue resistance in the contemporary alloys is ascribed to smaller inclusions in the Process-Optimized VIM+VAR material, and both smaller and fewer inclusions in the High-Purity VAR Nitinol.

  7. Parametric Instability Analysis of Deepwater Top-Tensioned Risers Considering Variable Tension Along the Length

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jie; TANG Yougang

    2015-01-01

    Parametric instability of a riser is caused by fluctuation of its tension in time due to the heave motion of floating plat-form. Many studies have tackled the problem of parametric instability of a riser with constant tension. However, tension in the riser actually varies linearly from the top to the bottom due to the effect of gravity. This paper presents the parametric instability analysis of deepwater top-tensioned risers (TTR) considering the linearly varying tension along the length. Firstly, the governing equation of transverse motion of TTR under parametric excitation is established. This equation is reduced to a system of ordinary differential equations by using the Galerkin method. Then the parametric instability of TTR for three calculation models are investigated by ap-plying the Floquet theory. The results show that the natural frequencies of TTR with variable tension are evidently reduced, the pa-rametric instability zones are significantly increased and the maximum allowable amplitude of platform heave is much smaller under the same damping; The nodes and antinodes of mode shape are no longer uniformly distributed along the axial direction and the am-plitude also changes with depth, which leads to coupling between the modes. The combination resonance phenomenon occurs as a result of mode coupling, which causes more serious damage.

  8. Static tensioning promotes hamstring tendons force relaxation more reliably than cycling tensioning.

    Science.gov (United States)

    Piedade, Sérgio Rocha; Dal Fabbro, Inácio Maria; Mischan, Martha Maria; Piedade, Cezar; Maffulli, Nicola

    2017-08-01

    Graft elongation might be a major reason for increased anterior laxity after anterior cruciate ligament (ACL) reconstruction. This study analyzed the force relaxation values and their stabilization when single strands of the gracilis and semitendinosus tendons underwent cyclic and static tensioning at 2.5% strain level, and compared the efficiency of static and cyclic tensioning in promoting force relaxation. Eighteen gracilis tendons and 18 semitendinosus tendons from nine male cadavers (mean age: 22.44years) were subjected to 10 in vitro cyclic loads at 2.5% strain level, or to a static load at 2.5% strain level. During cyclic loading, the reduction in force values tended to stabilize after the sixth cyclic load, while, in the case of static loading, this stabilization occurred by the second minute. Comparing static and cyclic loading, the gracilis tendon had similar mechanical responses in both conditions, while the semitendinosus tendon showed greater force relaxation in static compared with cyclic loading. Considering that the semitendinosus tendon is the main component of the hamstring graft, its biomechanical response to loading should guide the tensioning protocol. Therefore, static tensioning seems more effective for promoting force relaxation of the semitendinosus tendon than cyclic tensioning. The gracilis tendon showed a similar mechanical response to either tensioning protocols. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Micro-mechanical properties of 2219 welded joints with twin wire welding

    Institute of Scientific and Technical Information of China (English)

    Xu Wenli; Li Qingfen; Meng Qingguo; Fang Hongyuan; Gao Na

    2006-01-01

    Nanoindentation method was adopted to investigate the distribution regularities of micro-mechanical properties of 2219 twin wire welded joints, thus providing the necessary theoretical basis and guidance for joint strengthening and improvement of welding procedure.Experimental results show that in weld zone, micro-mechanical properties are seriously uneven.Both hardness and elastic modulus distribute as uneven sandwich layers, while micro-mechanical properties in bond area are much more uniform than weld zone;In heat-affected zone of 2219 twin wire welded joint, distribution regularity of hardness is similar to elastic modulus.The average hardness in quenching zone is higher than softening zone, and the average elastic modulus in solid solution zone is slightly higher than softening zone.As far as the whole welded joint is concerned,metal in weld possesses the lowest hardness.For welded specimens without reinforcement, fracture position is the weld when tensioning.While for welded specimens with reinforcement, bond area is the poorest position with joint strength coefficient of 61%.So, it is necessary to strengthen the poor positions-weld and bond area of 2219 twin wire welded joint in order to solve joint weakening of welding this kind of alloy.

  10. Optimization of Process Parameters in Wire Electrical Discharge Machining of MMC: A Review

    Directory of Open Access Journals (Sweden)

    J.M.Pujara

    2015-07-01

    Full Text Available Wire electrical discharge machining (WEDM is a specialized thermal machining process capable of accurately machining parts with varying hardness or complex shapes, which have sharp edges that are very difficult to be machined by the main stream machining processes. This practical technology of the WEDM process is based on the conventional EDM sparking phenomenon utilizing the widely accepted non-contact technique of material removal. Since the introduction of the process, WEDM has evolved from a simple means of making tools and dies to the best alternative of producing micro-scale parts with the highest degree of dimensional accuracy and surface finish quality. Metal matrix composites are advanced materials having high specific strength, good wear resistance, and high thermal expansion coefficient. To achieve this task, machining parameters such as pulse on time, pulse off time, peak current, servo voltage, wire feed, wire tension etc. of this process should be selected such that optimal value of their performance measures like Material Removal Rate (MRR, Surface Roughness (SR, Gap current, Dimensional deviation, etc. can be obtained or improved. In past decades, intensive research work had been carried out by different researchers for improvement and optimization of WEDM performance measures using various optimization techniques like Taguchi, Response Surface Methodology (RSM, Artificial Neural Network (ANN, Genetic Algorithm (GA, etc. This paper also highlights the feasibility of the different control strategies of obtaining the optimal machining conditions. This literature review helps to identify the suitable process parameters and their ranges in machining of metal matrix composites.

  11. Prediction of Material removal rate for Aluminum BIS-24345 Alloy in wire-cut EDM

    Directory of Open Access Journals (Sweden)

    PUJARI SRINIVASA RAO

    2010-12-01

    Full Text Available In the present work, the parametric optimization method using Taguchi’s robust design is proposed for wire-cut electric discharge machining of Aluminum BIS-24345 alloy. In the recent past this material gained dominance, where high strength and/or hardness is required at elevated temperatures. So, experimentation has been done by using Taguchi’s L18 (21x37 orthogonal array. Each experiment was conducted under different conditions of pulse on time, pulse off time, peak current, flushing pressure of dielectric fluid, wire feed rate, wire tension, spark gap voltage and servo feed setting. The response of material removal rate is considered for improving themachining efficiency. Optimal combinations of parameters were obtained by this method. Mathematical and artificial neural network models has been developed relating the machining performance and process parameters. The study shows that the Taguchi’s method is suitable to solve the stated problem with minimum number of trails as compared with a full factorial design.

  12. Rotary-bending fatigue characteristics of medical-grade Nitinol wire.

    Science.gov (United States)

    Pelton, A R; Fino-Decker, J; Vien, L; Bonsignore, C; Saffari, P; Launey, M; Mitchell, M R

    2013-11-01

    The rotary bending fatigue properties of medical-grade Nitinol wires were investigated under conditions of 0.5-10% strain amplitudes to a maximum of 10(7) cycles. The results from this study provide insight into the behavior of Nitinol under fully reversed (εmin/εmax=-1) fatigue conditions for three compositions, two surface conditions and three test temperatures. For pseudoelastic conditions there are four distinct regions of the strain-cycle curves that are related to phases (austenite, stress-induced martensite, and R-Phase) and their respective strain accommodation mechanisms. In contrast, there are only two regions for the strain-cycle curves for thermal martensite. It was further observed that the strain amplitude to achieve 10(7)-cycles increases with both decreasing test temperature and increasing transformation temperature. Fatigue behavior was not, however, strongly influenced by wire surface condition. SEM of the fracture surfaces showed that the fatigue fracture area increased with decreasing strain amplitude. Finite element analysis was used to illustrate strain distributions across the wire as well as to calculate the tension-compression contributions to the rotary bending curves. The results from this investigation are discussed with respect to mechanisms of strain accommodation under cyclic tensile and compressive conditions.

  13. Simulation Analysis of Standard Metal Specimen Tension Experiment by Fem

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>Some standard metal rod-shaped, plate-shaped or pipe-shaped specimens usually are used to be tensioned to acquire the material properties such as tensional ductility, contractibility ratio on breaking section,

  14. Surface and interfacial tension measurement, theory, and applications

    CERN Document Server

    Hartland, Stanley

    2004-01-01

    This edited volume offers complete coverage of the latest theoretical, experimental, and computer-based data as summarized by leading international researchers. It promotes full understanding of the physical phenomena and mechanisms at work in surface and interfacial tensions and gradients, their direct impact on interface shape and movement, and their significance to numerous applications. Assessing methods for the accurate measurement of surface tension, interfacial tension, and contact angles, Surface and Interfacial Tension presents modern simulations of complex interfacial motions, such a

  15. INFLUENCE OF SURFACE DEFECTS, INHERITED FROM ROLLED WIRE, ON QUALITY OF A COLD-DRAWN WIRE

    Directory of Open Access Journals (Sweden)

    A. N. Savenok

    2012-01-01

    Full Text Available Researches of the most often occurred surface defects of rolled wires, their modification at drawing and influence on technological process and quality of cold-drawn wire with regard to working conditions of hardware shops of OAO “BMZ” are  presented.

  16. INFLUENCE OF THE SURFACE DEFECTS INHERITED FROM ROLLED WIRE ON QUALITY OF COLD DRAWN WIRE

    Directory of Open Access Journals (Sweden)

    A. N. Savenok

    2012-01-01

    Full Text Available Researches of the most often occurred surface defects of rolled wires, their modification at drawing and influence on technological process and quality of cold-drawn wire with regard to working conditions of hardware shops of BMZ are presented.

  17. Evolution of cementite morphology in pearlitic steel wire during wet wire drawing

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2010-01-01

    The evolution of the cementite phase during wet wire drawing of a pearlitic steel wire has been followed as a function of strain. Particular attention has been given to a quantitative characterization of changes in the alignment and in the dimensions of the cementite phase. Scanning electron...

  18. STRS SpaceWire FPGA Module

    Science.gov (United States)

    Lux, James P.; Taylor, Gregory H.; Lang, Minh; Stern, Ryan A.

    2011-01-01

    An FPGA module leverages the previous work from Goddard Space Flight Center (GSFC) relating to NASA s Space Telecommunications Radio System (STRS) project. The STRS SpaceWire FPGA Module is written in the Verilog Register Transfer Level (RTL) language, and it encapsulates an unmodified GSFC core (which is written in VHDL). The module has the necessary inputs/outputs (I/Os) and parameters to integrate seamlessly with the SPARC I/O FPGA Interface module (also developed for the STRS operating environment, OE). Software running on the SPARC processor can access the configuration and status registers within the SpaceWire module. This allows software to control and monitor the SpaceWire functions, but it is also used to give software direct access to what is transmitted and received through the link. SpaceWire data characters can be sent/received through the software interface, as well as through the dedicated interface on the GSFC core. Similarly, SpaceWire time codes can be sent/received through the software interface or through a dedicated interface on the core. This innovation is designed for plug-and-play integration in the STRS OE. The SpaceWire module simplifies the interfaces to the GSFC core, and synchronizes all I/O to a single clock. An interrupt output (with optional masking) identifies time-sensitive events within the module. Test modes were added to allow internal loopback of the SpaceWire link and internal loopback of the client-side data interface.

  19. 谈高边坡预应力锚索施工技术%Discussion on the construction technology of high slope prestressed anchor wire

    Institute of Scientific and Technical Information of China (English)

    李东升

    2012-01-01

    Combining with the successful application example of prestressed anchor wire in the high slope management after waste management engineering blasting in the tunnel entrance of new high-speed railway five peak temple in Hangyong,from the prestressed anchor wire drilling,anchor wire entrance,grouting,anchor pier security system,anchor wire tensioning,locking,anchor wire sealing and other construction technology,emphatically introduced the construction technology of prestressed anchor wire strengthening high slope,ensured the stability of the slope,and achieved good results.%结合预应力锚索在新建杭甬高速铁路五峰寺隧道入口处废矿治理工程爆破后遗留的高边坡治理的成功应用实例,从预应力锚索的钻孔、锚索入孔、注浆、锚墩制安、锚索张拉、锁定、封锚等施工工艺入手,重点介绍了预应力锚索加固高边坡的施工技术,保证了边坡的稳定性,取得了良好的效果。

  20. Modelling Tension Stiffening in Reinforced Concrete Structures

    DEFF Research Database (Denmark)

    Christiansen, Morten Bo; Nielsen, Mogens Peter

    1997-01-01

    flexure.In the first model, the yield zone model, it is assumed that the mean crack distance is a descending function of the reinforcement stress in a crack. Furthermore it is assumed that in certain zones between the cracks the concrete is carrying its full effective tensile strength, i.e. the concrete...... with deformations in reinforced concrete disks subjected to pure shear.A physical model for the shear stress-shear strain behaviour of disks, including tension stiffening, is proposed.In the disk model it is assumed that the tensile principal stress in the concrete decreases linearly from the initiation of cracking...... until a certain load level. At any load level the model can predict the shear strains of the disk and the inclination of the crack system. When regarding tension stiffening this latter parameter will be a function of the load level.The model is compared with experimental data, and in the light...

  1. Scaling for interfacial tensions near critical endpoints.

    Science.gov (United States)

    Zinn, Shun-Yong; Fisher, Michael E

    2005-01-01

    Parametric scaling representations are obtained and studied for the asymptotic behavior of interfacial tensions in the full neighborhood of a fluid (or Ising-type) critical endpoint, i.e., as a function both of temperature and of density/order parameter or chemical potential/ordering field. Accurate nonclassical critical exponents and reliable estimates for the universal amplitude ratios are included naturally on the basis of the "extended de Gennes-Fisher" local-functional theory. Serious defects in previous scaling treatments are rectified and complete wetting behavior is represented; however, quantitatively small, but unphysical residual nonanalyticities on the wetting side of the critical isotherm are smoothed out "manually." Comparisons with the limited available observations are presented elsewhere but the theory invites new, searching experiments and simulations, e.g., for the vapor-liquid interfacial tension on the two sides of the critical endpoint isotherm for which an amplitude ratio -3.25+/-0.05 is predicted.

  2. Thermal Analysis of Bending Under Tension Test

    DEFF Research Database (Denmark)

    Ceron, Ermanno; Martins, Paulo A.F.; Bay, Niels

    2014-01-01

    The tribological conditions in deep drawing can be simulated in the Bending Under Tension test to evaluate the performance of new lubricants, tool materials, etc. Deep drawing production with automatic handling runs normally at high rate. This implies considerable heating of the tools, which...... sometimes can cause lubricant film breakdown and galling. In order to replicate the production conditions in bending under tension testing it is thus important to control the tool/workpiece interface temperature. This can be done by pre-heating the tool, but it is essential that the interface temperature...... during testing is similar to the one in the production tool. A universal sheet tribo-tester has been developed, which can run multiple tests automatically from coil. This allows emulating the temperature increase as in production. The present work performs finite element analysis of the evolution...

  3. Separation anxiety: Stress, tension and cytokinesis

    Energy Technology Data Exchange (ETDEWEB)

    Mohan, Krithika [Department of Electrical and Computer Engineering, The Johns Hopkins University, 3400 N. Charles Street, Baltimore, MD 21218 (United States); Iglesias, Pablo A., E-mail: pi@jhu.edu [Department of Electrical and Computer Engineering, The Johns Hopkins University, 3400 N. Charles Street, Baltimore, MD 21218 (United States); Robinson, Douglas N., E-mail: dnr@jhmi.edu [Department of Cell Biology, Johns Hopkins University School of Medicine, 725 N. Wolfe Street, Baltimore, MD 21205 (United States)

    2012-07-15

    Cytokinesis, the physical separation of a mother cell into two daughter cells, progresses through a series of well-defined changes in morphology. These changes involve distinct biochemical and mechanical processes. Here, we review the mechanical features of cells during cytokinesis, discussing both the material properties as well as sources of stresses, both active and passive, which lead to the observed changes in morphology. We also describe a mechanosensory feedback control system that regulates protein localization and shape progression during cytokinesis. -- Highlights: Black-Right-Pointing-Pointer Cytokinesis progresses through three distinct mechanical phases. Black-Right-Pointing-Pointer Cortical tension initially resists deformation of mother cell. Black-Right-Pointing-Pointer Late in cytokinesis, cortical tension provides stress, enabling furrow ingression. Black-Right-Pointing-Pointer A mechanosensory feedback control system regulates cytokinesis.

  4. Bending Under Tension Test with Direct Friction Measurement

    DEFF Research Database (Denmark)

    Andreasen, Jan Lasson; Olsson, David Dam; Chodnikiewicz, K.

    2004-01-01

    A special BUT-transducer has been developed in which friction around the tool radius can be directly measured when drawing a plane sheet strip around a cylindrical tool-pin under constant back tension. The front tension, back tension and torque on the tool-pin are all measured directly, thus enab...

  5. Tensions of Teaching Media Literacy in Teacher Education

    Science.gov (United States)

    Ngomba-Westbrook, Nalova Elaine

    2013-01-01

    This study investigates the tensions a teacher educator faces in facilitating a media literacy teacher education course at the university level. Teaching tensions are conceptualized as a three-tier framework. At the first level, tensions may arise in the selection and application of pedagogies associated with critical and new/21st century…

  6. The effect of multiple bending of wire on the residual stresses of high carbon steel wires

    Directory of Open Access Journals (Sweden)

    R. Kruzel

    2013-01-01

    Full Text Available Steel tire cord, springs and rope wires belong to the group of metal products from which the low residual stresses are required. In this paper the effect of multiple bending of wire on residual stresses of high carbon steel wires has been assessed. It was found that the application of the multi-roller straightening machine in the banding wire process enables to reduce the residual stresses in the drawn wires. It should be also noted that the value of the residual stresses depends on the type of straightener construction. The residual stresses on the basis of stress-strain curve has been determined. It has been stated that the application of seven-rolls straightener gives the best effect of straightening.

  7. Selected developments in laser wire stripping. [cutting insulation from aerospace-type wires and cables

    Science.gov (United States)

    1977-01-01

    The operation of mechanical and thermal strippers and the early development of laser wire strippers are reviewed. NASA sponsored development of laser wire stripping for space shuttle includes bench-type strippers as well as an advanced portable hand-held stripper which incorporates a miniaturized carbon dioxide laser and a rotating optics unit with a gas-jet assist and debris exhaust. Drives and controls girdle the wire and slit the remaining slug without manual assistance. This unit can strip wire sizes 26 through 12 gage. A larger-capacity hand-held unit for wire sizes through 1/0 gage was built using a neodynium-doped yttrium aluminum garnet (Nd:YAG) laser. The hand-held units have a flexible umbilical cable to an accompanying cart that carries the power supply, gas supply, cooling unit, and the controls.

  8. A microprocessor based portable bolt tension monitor

    Science.gov (United States)

    Perey, D. F.

    1991-01-01

    A bolt tension monitor (BTM) which uses ultrasonics and a pulsed phase locked loop circuit to measure load-induced acoustic phase shifts which are independent of friction is described. The BTM makes it possible to measure the load in a bolt that was tightened at some time in the past. This capability to recertify a load after-the-fact will help to insure the integrity of a bolted joint.

  9. 2-rational Cubic Spline Involving Tension Parameters

    Indian Academy of Sciences (India)

    M Shrivastava; J Joseph

    2000-08-01

    In the present paper, 1-piecewise rational cubic spline function involving tension parameters is considered which produces a monotonic interpolant to a given monotonic data set. It is observed that under certain conditions the interpolant preserves the convexity property of the data set. The existence and uniqueness of a 2-rational cubic spline interpolant are established. The error analysis of the spline interpolant is also given.

  10. Tension-induced binding of semiflexible biopolymers

    CERN Document Server

    Benetatos, Panayotis; Zippelius, Annette

    2014-01-01

    We investigate theoretically the effect of polymer tension on the collective behavior of reversibly binding cross-links. For this purpose, we employ a model of two weakly bending wormlike chains aligned in parallel by a tensile force, with a sequence of inter-chain binding sites regularly spaced along the contours. Reversible cross-links attach and detach at the sites with an affinity controlled by a chemical potential. In a mean-field approach, we calculate the free energy of the system and find the emergence of a free-energy barrier which controls the reversible (un)binding. The tension affects the conformational entropy of the chains which competes with the binding energy of the cross-links. This competition gives rise to a sudden increase in the fraction of bound sites as the tension increases. We show that this transition is related to the cross-over between weak and strong localization of a directed polymer in a pinning potential. The cross-over to the strongly bound state can be interpreted as a mechan...

  11. Vibration measurements of a wire scanner - Experimental setup and models

    Science.gov (United States)

    Herranz, Juan; Barjau, Ana; Dehning, Bernd

    2016-03-01

    In the next years the luminosity of the LHC will be significantly increased. This will require a much higher accuracy of beam profile measurement than actually achievable by the current wire scanner. The new performance demands a wire travelling speed up to 20 m s-1 and a position measurement accuracy of the order of 1 μm. The vibrations of the mechanical parts of the system and particularly the vibrations of the thin carbon wire have been identified as the major error sources of wire position uncertainty. Therefore the understanding of the wire vibrations has been given high priority for the design and operation of the new device. This article presents a new strategy to measure the wire vibrations based on the piezoresistive effect of the wire itself. An electronic readout system based on a Wheatstone bridge is used to measure the variation of the carbon wire resistance, which is directly proportional to the wire elongation caused by the oscillations.

  12. 拉丝过程中线振动导致的拉模磨损模拟%Advanced simulation of die wear caused by wire vibrations during wire-drawing process

    Institute of Scientific and Technical Information of China (English)

    LEE Kyung-Hun; LEE Sang-Kon; KIM Byung-Min

    2012-01-01

    考虑到拉丝工艺过程中线振动的影响而建立一个能精确预测磨具磨损的模型.利用该模型研究了线振动的影响、磨损轮廓的变化、振荡的产生.出现在磨具和突起之间的线振动服从偏微分方程,也称波动方程.该方程是一个与拉丝长度、张力、密度和初始线速度有关的函数.用商业Abaqus软件来模拟拉丝工艺过程,并应用Archard磨损模型预测模具磨损.在生产5 t AISI 1010线材的情况下,将预测的磨损与实际的磨损进行对比.磨具是布氏硬度为HB682的碳化钨.考虑了线振动影响的预测结果与实验结果相当一致,表明所建立的模型能够精确预测存在振荡的磨具磨损.%An advanced simulation that considers the effect of wire vibrations was proposed for predicting accurately wear profiles of a die used in a wire-drawing process.The effect of wire vibrations,the changes in the wear profiles,and the generation of ringing during die approach were investigated by this simulation.Wire vibrations occurring between the die and the drum are governed by a partial differential equation called the wave equation,which is a function of the wire length,tension,density,and initial wire velocity.The wire-drawing process was simulated by the commercial code Abaqus FEA,and the die wear profiles were predicted by Archard's wear model.The predicted profiles were compared with measured profiles of a worn drawing die after producing 5 t of AISI 1010 wire; the die was made of tungsten carbide with a Brinell hardness of HB 682.The profiles predicted by considering the effect of wire vibrations are in good agreement with the experimental data,indicating that the advanced simulation can be used to accurately predict the die wear profiles when ringing is observed during die approach.

  13. Integrated Electrical Wire Insulation Repair System

    Science.gov (United States)

    Williams, Martha; Jolley, Scott; Gibson, Tracy; Parks, Steven

    2013-01-01

    An integrated system tool will allow a technician to easily and quickly repair damaged high-performance electrical wire insulation in the field. Low-melt polyimides have been developed that can be processed into thin films that work well in the repair of damaged polyimide or fluoropolymer insulated electrical wiring. Such thin films can be used in wire insulation repairs by affixing a film of this low-melt polyimide to the damaged wire, and heating the film to effect melting, flow, and cure of the film. The resulting repair is robust, lightweight, and small in volume. The heating of this repair film is accomplished with the use of a common electrical soldering tool that has been modified with a special head or tip that can accommodate the size of wire being repaired. This repair method can furthermore be simplified for the repair technician by providing replaceable or disposable soldering tool heads that have repair film already "loaded" and ready for use. The soldering tool heating device can also be equipped with a battery power supply that will allow its use in areas where plug-in current is not available

  14. EVALUATION OF INDUCTANCE WITH ELECTRICAL WIRES

    Directory of Open Access Journals (Sweden)

    V. Kudry

    2016-08-01

    Full Text Available In this paper proved the possibility of developing passive electronic inductive elements based replace metal wire that is wound inductor, the wire is made of electret. The relative permeability of the electret S  10 000, several orders of magnitude greater than the permeability of conventional insulation materials, i < 10, resulting current in the wire acquires properties bias current. The essence of innovation is to replace the source of of magnetic induction flow that pervades the core of the coil. According to the theory of electrodynamics, current bias, in contrast to conduction current, generated no movement of charge along the wire, but the change of the charge in the local volume.Equivalence bias current and conduction current is manifested in the possibility of forming a magnetic field. The flow through magnetic induction coil core regardless of the current it generates, creates voltage at its ends.The paper also shows the numeric characteristics that determine the effective frequency range, specified the reason why electric a wire with і < 10 can not generate magnetic flux through the core and serve as a passive reactive component.

  15. Forgotten Kirschner Wire Causing Severe Hematuria

    Directory of Open Access Journals (Sweden)

    Santosh Kumar

    2014-01-01

    Full Text Available Kirschner wire (K-wire is commonly used in the treatment of hip fracture and its migration into pelvis leading to bladder injury is a very rare complication. Nonremoval of these devices either because of lack of followup or because of prolonged requirement due to disease process is associated with this complication. We report a case of a patient who presented with acute onset severe hematuria with clot retention secondary to perforation of bladder by a migrated K-wire placed earlier, for the treatment of hip fracture. Initial imaging showed its presence in the soft tissues of the pelvis away from the major vascular structures. Patient was taken for emergency laparotomy and wire was removed after cystotomy. Postoperative period was uneventful and patient was discharged in satisfactory condition. K-wires are commonly used in the management of fracture bones and their migration has been reported in the literature although such migration in the intrapelvic region involving bladder is very rare. Early diagnosis and prompt removal of such foreign bodies are required to avert potentially fatal involvement of major structures.

  16. The PS Booster Fast Wire Scanner

    CERN Document Server

    Burger, S; Priestnall, K; Raich, U

    2003-01-01

    The very tight emittance budget for LHC type beams makes precise emittance measurements in the injector complex a necessity. The PS machine uses 2 fast wire scanners per transverse plane for emittance measurement of the circulating beams. In order to ease comparison the same type of wire scanners have been newly installed in the upstream machine, the PS Booster, where each of the 4 rings is equipped with 2 wire scanners measuring the horizontal and vertical profiles. Those wire scanners use new and more modern control and readout electronics featuring dedicated intelligent motor movement controllers, which relieves the very stringent real time constraints due to the very high speed of 20m/s. In order to be able to measure primary beams at the very low injection energy of the Booster (50MeV) secondary emission currents from the wire can be measured as well as secondary particle flows at higher primary particle energies during and after acceleration. The solution adopted for the control of the devices is descri...

  17. Optimal welding of beta titanium orthodontic wires.

    Science.gov (United States)

    Nelson, K R; Burstone, C J; Goldberg, A J

    1987-09-01

    Today the orthodontist is confronted by an array of new orthodontic wire materials that, when applied to appliance design, can vastly increase the flexibility and versatility of therapy. Welded joints, especially for the newer titanium alloy wires, provide a means to extend the useful applications of these materials. The purpose of this study was to determine the optimum settings for electrical resistance welding of various configurations of titanium-molybdenum (TMA) wires. Specimens were of a t-joint configuration and were mechanically tested in torsion to simulate the failure mode most often observed in clinical practice. Variables included wire size, wire orientation, and welding voltage. Results indicated that excellent welds can be obtained with very little loss of strength and ductility in the area of the weld joint. Torsional loads at failure were at least 90% of the unwelded base material. Although a wide range of voltage settings resulted in high-strength welds, typically a narrow range of voltages yielded optimal ductility.

  18. Forgotten Kirschner wire passing across the sigmoid colon.

    Science.gov (United States)

    Matsumoto, Hiroshi; Yo, Shogen; Fukushima, Shinya; Osawa, Motoyasu; Murao, Takahiro; Ishii, Manabu; Fujita, Minoru; Shiotani, Akiko

    2017-04-01

    The Kirschner wire (K-wire) is used in the treatment of hip fractures, and migration of a K-wire into the pelvis with resultant colon injury is a very rare complication. We report a case in which a forgotten K-wire passing across the sigmoid colon was accidentally found by screening colonoscopy in a patient with no abdominal symptoms. Surgery was performed to remove the K-wire. Although the migration of a K-wire is extremely rare, it is important for it to be considered in patients with a history of orthopedic surgery.

  19. Heat-transfer regularities of the anemometric wire

    Science.gov (United States)

    Mikheev, N. I.; Sakhovsky, A. V.; Khairnasov, K. R.; Kratirov, D. V.

    2010-06-01

    Experimental heat-transfer data for a small-diameter hot wire have been obtained and generalized in a wide range of Reynolds numbers typical of hot-wire anemometry. The experiments were carried out using an IRVIS-TA5 digital hot-wire anemometer and standard critical nozzles used for regulating the flow in the test section of the Eiffel chamber in which the hot-wire sensor was installed. Approaches to carrying out hot-wire anemometric measurements without a labor-consuming calibration procedure for the hot-wire sensor are substantiated.

  20. Optimization of the Single Staggered Wire and Tube Heat Exchanger

    OpenAIRE

    Arsana I Made; Susianto; Budhikarjono Kusno; Altway Ali

    2016-01-01

    Wire and tube heat exchanger consists of a coiled tube, and wire is welded on the two sides of it in normal direction of the tube. Generally,wire and tube heat exchanger uses inline wire arrangement between the two sides, whereas in this study, it used staggered wire arrangement that reduces the restriction of convection heat transfer. This study performed the optimization of single staggered wire and tube heat exchanger to increase the capacity and reduce the mass of the heat exchanger. Opti...

  1. Ultrasonic Welding of Wires and Cables

    Science.gov (United States)

    Heinz, Stefan; Wagner, Guntram; Eifler, Dietmar

    2012-03-01

    In the automobile industry, ultrasonic metal welding is an established method. At the Institute of Materials Science and Engineering (WKK) at the University of Kaiserslautern, Germany, systematic investigations of the weldability of Al-wires and flat flexible copper cables were carried out. In the case of Al-wires, joints with cross-sectional area of up to 80 mm2 and tensile shear load of about 3500 N were finally realized. Furthermore, methods to reduce unintentional adherence between the sonotrode coupling face and the Al-wires were developed. To realize FFC joints, ultrasonic spot welding systems and ultrasonic torsion welding systems were used. A central purpose of these investigations is the development of a system to enable welding through the insulation of the FFC without weakening the base material.

  2. Induced voltage in an open wire

    CERN Document Server

    Morawetz, K; Trupp, A

    2015-01-01

    A puzzle arising from Faraday's law is considered and solved concerning the question which voltage is induced in an open wire feeling a time-varying homogeneous magnetic field. The longitudinal electric field contributes 1/3 and the transverse field 2/3 to the induced voltage. The representation of a homogeneous and time-varying magnetic field implies unavoidably a certain symmetry point or line dependent on the geometry of the source. As a consequence the induced voltage of an open wire is found to be the area covered with respect to the symmetry line or point perpendicular to the magnetic field. This in turn allows to find the symmetry points of a magnetic field source by measuring the voltage of an open wire. We present two exactly solvable models for a symmetry point and for a symmetry line. The results are applicable to open circuit problems and for astrophysical applications.

  3. Reusable Hot-Wire Cable Cutter

    Science.gov (United States)

    Pauken, Michael T.; Steinkraus, Joel M.

    2010-01-01

    During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which

  4. Hot-wire anemometry in transonic flow

    Science.gov (United States)

    Horstman, C. C.; Rose, W. C.

    1977-01-01

    The use of hot-wire anemometry for obtaining fluctuating data in transonic flows has been evaluated. From hot-wire heat loss correlations based on previous transonic data, the sensitivity coefficients for velocity, density, and total temperature fluctuations have been calculated for a wide range of test conditions and sensor parameters. For sensor Reynolds number greater than 20 and high sensor overheat ratios, the velocity sensitivity remains independent of Mach number and equal to the density sensitivity. These conditions were verified by comparisons of predicted sensitivities with those from recent direct calibrations in transonic flows. Based on these results, techniques are presented to obtain meaningful measurements of fluctuating velocity, density, and Reynolds shear stress using hot-wire and hot-film anemometers. Example of these measurements are presented for two transonic boundary layers.

  5. Hot wire anemometry in transonic flow

    Science.gov (United States)

    Horstman, C. C.; Rose, W. C.

    1975-01-01

    The use of hot-wire anemometry for obtaining fluctuating data in transonic flows has been evaluated. From hot-wire heat loss correlations based on previous transonic data, the sensitivity coefficients for velocity, density, and total temperature fluctuations have been calculated for a wide range of test conditions and sensor parameters. For sensor Reynolds numbers greater than 20 and high sensor overheat ratios, the velocity sensitivity remains independent of Mach number and equal to the density sensitivity. These conclusions were verified by comparisons of predicted sensitivities with those from recent direct calibrations in transonic flows. Based on these results, techniques are presented to obtain meaningful measurements of fluctuating velocity, density, and Reynolds shear stress using hot-wire and hot-film anemometers. Examples of these measurements are presented for two transonic boundary layers.

  6. A new route to process diamond wires

    Directory of Open Access Journals (Sweden)

    Marcello Filgueira

    2003-06-01

    Full Text Available We propose an original route to process diamond wires, denominated In Situ Technology, whose fabrication involves mechanical conformation processes, such as rotary forging, copper tubes restacking, and thermal treatments, such as sintering and recrystallisation of a bronze 4 wt.% diamond composite. Tensile tests were performed, reaching an ultimate tensile strength (UTS of 230 MPa for the diameter of Æ = 1.84 mm. Scanning electron microscopy showed the diamond crystals distribution along the composite rope during its manufacture, as well as the diamond adhesion to the bronze matrix. Cutting tests were carried out with the processed wire, showing a probable performance 4 times higher than the diamond sawing discs, however its probable performance was about 5 to 8 times less than the conventional diamond wires (pearl system due to the low abrasion resistance of the bronze matrix, and low adhesion between the pair bronze-diamond due to the use of not metallised diamond single crystals.

  7. Emulating Wired Backhaul with Wireless Network Coding

    DEFF Research Database (Denmark)

    Thomsen, Henning; De Carvalho, Elisabeth; Popovski, Petar

    2014-01-01

    of the two-way protocol. The transmit power is set high enough to enable successive decoding at the small cell base station where the downlink data to the user is first decoded and its contribution removed from the received signal followed by the uplink data from the user. The decoding of the second layer......In this paper we address the need for wireless network densification. We propose a solution wherein the wired backhaul employed in heterogeneous cellular networks is replaced with wireless links, while maintaining the rate requirements of the uplink and downlink traffic of each user. The first......, the uplink traffic to the user, remains identical to the one performed in a wired system. In the broadcast phase, the decoding of the downlink traffic can also be guaranteed to remain identical. Hence, our solution claims an emulation of a wired backhaul with wireless network coding with same performance. We...

  8. Mechanical and microstructural characterization of new nickel-free low modulus β-type titanium wires during thermomechanical treatments

    Energy Technology Data Exchange (ETDEWEB)

    Guillem-Martí, J. [Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Metallurgy, Technical University of Catalonia (UPC), ETSEIB, Av. Diagonal 647, 08028 Barcelona (Spain); Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Campus Río Ebro, Edificio I+D Bloque 5, 1a planta, C/ Poeta Mariano Esquillor s/n, 50018 Zaragoza (Spain); Centre for Research in NanoEngineering (CRNE) – UPC, C/Pascual i Vila 15, 08028 Barcelona (Spain); Herranz-Díez, C. [Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Metallurgy, Technical University of Catalonia (UPC), ETSEIB, Av. Diagonal 647, 08028 Barcelona (Spain); Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Campus Río Ebro, Edificio I+D Bloque 5, 1a planta, C/ Poeta Mariano Esquillor s/n, 50018 Zaragoza (Spain); Shaffer, J.E. [Fort Wayne Metals Research Products Corporation, 9609 Ardmore Avenue, 46809 Fort Wayne (United States); Gil, F.J. [Biomaterials, Biomechanics and Tissue Engineering Group, Department of Materials Science and Metallurgy, Technical University of Catalonia (UPC), ETSEIB, Av. Diagonal 647, 08028 Barcelona (Spain); Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Campus Río Ebro, Edificio I+D Bloque 5, 1a planta, C/ Poeta Mariano Esquillor s/n, 50018 Zaragoza (Spain); Centre for Research in NanoEngineering (CRNE) – UPC, C/Pascual i Vila 15, 08028 Barcelona (Spain); and others

    2015-06-11

    NiTi alloy is the only practical shape memory alloy (SMA) in biomedical use because of its excellent mechanical stability and functionality. However, it is estimated that between 4.5% and 28.5% of the population are hypersensitive to nickel metal, with a higher prevalence in females. Therefore, developing nickel-free low modulus β-type titanium alloys showing shape memory or super elastic behavior would have a great interest in the biomaterials field. Homogeneous 127 μm diameter Ti25Hf21Nb wires were produced and compared to straight annealed Ti–50.8 at% Ni (Nitinol) and 90% cold-drawn 316L wires. Microstructural changes taking place during the heat treatment of cold-worked Ti25Hf21Nb wires were investigated. Large plastic deformation during wire drawing and subsequent annealing led to nano-crystallization and amorphization which may contribute to the observed superelasticity. Mechanical properties were characterized using cyclic uniaxial tension and rotary beam fatigue test modes. A modulus of elasticity of less than 60 GPa and axial recoverable strain of greater than 3% were observed with stress hysteresis resembling a reversible stress-induced martensitic transformation at higher temperatures. The new Ti25Hf21Nb alloy is an important candidate for developing Ni-free SMAs in the future.

  9. Toward a general psychological model of tension and suspense

    Directory of Open Access Journals (Sweden)

    Moritz eLehne

    2015-02-01

    Full Text Available Tension and suspense are powerful emotional experiences that occur in a wide variety of contexts (e.g., in music, film, literature, and everyday life. The omnipresence of tension experiences suggests that they build on very basic cognitive and affective mechanisms. However, the psychological underpinnings of tension experiences remain largely unexplained, and tension and suspense are rarely discussed from a general, domain-independent perspective. In this paper, we argue that tension experiences in different contexts (e.g., musical tension or suspense in a movie build on the same underlying psychological processes. We discuss key components of tension experiences and propose a domain-independent model of tension and suspense. According to this model, tension experiences originate from states of conflict, instability, dissonance, or uncertainty that trigger predictive processes directed at future events of emotional significance. We also discuss possible neural mechanisms underlying experiences of tension. The model provides a theoretical framework that can inform future empirical research on tension phenomena.

  10. Temperature effect on DNA molecular wires

    Science.gov (United States)

    Bui, Christopher Minh

    The demand of technology and information today has further pushed the fabrication process of nanotechnology, yet there are limits and obstacles set by the primary laws of physics. Therefore, researchers are pursuing alternative technologies. Deoxyribonucleic acids (DNA) molecular wire is one advantageous option due to its unique characteristics including self-assembly and naturally small; size. This thesis reports the temperature effect on the electrical properties of a double-stranded ?-DNA molecular wire. The data will help expand the DNA wire application and functionality. Thus, the data supports the charge hopping theory on DNA electrical conductivity. Diverse amount of literatures has demonstrated that DNA experiences a biochemical alteration when exposed under different temperature conditions. This change will also cause a change in the electrical properties. In this research, DNA will hang between two gold covered microelectrodes with a distance of 10 to 12 microns. The microelectrodes are fabricated through negative lithography techniques. Then, the samples were exposed to a numerous range of temperature from 25°C to 180°C and went through varying cycles of heating and cooling. The experimental results revealed that the DNA experienced a hysteresis like behavior where the impedance differed between the heating and cooling phase. The impedance of the DNA molecular wire increased when exposed to higher temperature. Furthermore, the impedance stops increasing after a certain amount of heat cycles before the DNA structure failed. The biology and thermodynamics of the DNA wire was analyzed due to the temperature hysteresis effect. The melting temperature and the bond dissociation temperature were evaluated to determine the cause of the impedance trends. The studies and analysis of the temperature effect provided certain insights towards the charge hopping transport mechanism. The thesis concludes with possible applications relating to the temperature effect of

  11. A disposable, coated wire heparin sensor.

    Science.gov (United States)

    Yun, J H; Fu, B; Meyerhoff, M E; Yang, V C

    1994-01-01

    The development of an ion-selective electrode heparin sensor consisting of a specially formulated polymer membrane doped with tridodecylmethylammonium chloride as the heparin complexing agent was recently reported. Because of the simple nature of the membrane technology used, the authors envisioned that the sensor could be configured as a disposable single-use device for rapid clinical or bedside measurement of heparin in a small, discrete sample. To explore this possibility, an inexpensive, disposable heparin sensor was created by dip-coating a copper wire with the specially formulated heparin-sensing polymeric membrane. Coated wire heparin sensors with a broad range of membrane thicknesses, prepared by repeatedly dipping the wire in the membrane solution for various times, were examined. Data show that increasing the membrane thickness of the sensor to a certain degree (more than 10 microns) enhanced the sensor's potentiometric response to heparin, although the time required to achieve 90% of the steady-state potential change was also prolonged. In addition, increasing membrane thickness also magnified the stirring effect on the sensor's response. In undiluted plasma samples, the coated-wire sensor with an optimized membrane thickness yielded a significant (5 to 30 mV) and reproducible response to heparin in a clinically relevant concentration range (0.5 to 12 units/ml, respectively). The clinical utility of the coated wire heparin sensor was shown using the sensor during protamine titration of heparinized plasma to assess the titration end-point. Preliminary results showed that the titration end-points determined by the heparin sensor strongly correlated with those determined by the activated partial thromboplastin time clotting assay. The overall time requirement to complete the titration process using a set of prefabricated coated wire heparin sensors, however, was less than 3 minutes. Further titration studies using undiluted clinical whole blood samples are

  12. The aging of wire chambers filled with dimethyl ether: Wire and construction materials and freon impurities

    Energy Technology Data Exchange (ETDEWEB)

    Jibaly, M.; Majewski, S.; Chrusch, P. Jr.; Wojcik, R. (Florida Univ., Gainesville (USA). Dept. of Physics (USA)); Sauli, F.; Gaudaen, J. (European Organization for Nuclear Research, Geneva (Switzerland). EP-Div. (Switzerland))

    1989-11-10

    This is a complete summary of our study of the aging of different types of wire chambers, with a variety of construction materials and wires, filled with dimethyl ether (DME) of varying degrees of purity. The resistive Nicotin and Stablohm wires were corroded by DME, producing fast aging. The moderately resistive stainless steel wires were able to withstand extended irradiation (up to 1 C/cm) in high-purity DME without any apparent damage; and gold-plated tungsten and molybdenum wires exhibited a comparable behavior. Many construction materials were tested and recommendations are thus reached as to what kinds of materials are safe in building DME-operated wire chambers. Among many different Freon and hydrocarbon impurities detected in DME by means of gas chromatography (GC), Freon-11 was found to be mostly responsible for the aging, even with noncorrosive stainless steel or gold-plated wires. The availability and feasibility of obtaining Freon-free DME is reported as well. (orig.).

  13. Physarum wires: Self-growing self-repairing smart wires made from slime mould

    CERN Document Server

    Adamatzky, Andrew

    2013-01-01

    We report experimental laboratory studies on developing conductive pathways, or wires, using protoplasmic tubes of plasmodium of acellular slime mould Physarum polycephalum. Given two pins to be connected by a wire, we place a piece of slime mould on one pin and an attractant on another pin. Physarum propagates towards the attract and thus connects the pins with a protoplasmic tube. A protoplasmic tube is conductive, can survive substantial over-voltage and can be used to transfer electrical current to lightning and actuating devices. In experiments we show how to route Physarum wires with chemoattractants and electrical fields. We demonstrate that Physarum wire can be grown on almost bare breadboards and on top of electronic circuits. The Physarum wires can be insulated with a silicon oil without loss of functionality. We show that a Physarum wire self-heals: end of a cut wire merge together and restore the conductive pathway in several hours after being cut. Results presented will be used in future designs ...

  14. Principles of intramedullary pin and wire fixation.

    Science.gov (United States)

    Howard, P E

    1991-02-01

    Knowledge and experience in the proper use of IM pins, K-wires, and orthopedic wire is a valuable asset to the veterinarian's ability to successfully repair a variety of long bone fractures. Most long bone fractures are amenable to repair with this form of fixation. When the principles of application are violated or the implants are used when contraindicated, complications often occur. Proper use of these implants results in the successful management of complex fractures to the satisfaction of both the animal owner and the veterinarian (Fig 10).

  15. Temperature Dependent Wire Delay Estimation in Floorplanning

    DEFF Research Database (Denmark)

    Winther, Andreas Thor; Liu, Wei; Nannarelli, Alberto;

    2011-01-01

    Due to large variations in temperature in VLSI circuits and the linear relationship between metal resistance and temperature, the delay through wires of the same length can be different. Traditional thermal aware floorplanning algorithms use wirelength to estimate delay and routability. In this w......Due to large variations in temperature in VLSI circuits and the linear relationship between metal resistance and temperature, the delay through wires of the same length can be different. Traditional thermal aware floorplanning algorithms use wirelength to estimate delay and routability...

  16. CODEX sounding rocket wire grid collimator design

    Science.gov (United States)

    Shipley, Ann; Zeiger, Ben; Rogers, Thomas

    2011-05-01

    CODEX is a sounding rocket payload designed to operate in the soft x-ray (0.1-1.0 kV) regime. The instrument has a 3.25 degree square field of view that uses a one meter long wire grid collimator to create a beam that converges to a line in the focal plane. Wire grid collimator performance is directly correlated to the geometric accuracy of actual grid features and their relative locations. Utilizing a strategic combination of manufacturing and assembly techniques, this design is engineered for precision within the confines of a typical rocket budget. Expected resilience of the collimator under flight conditions is predicted by mechanical analysis.

  17. Laser wire emittance measurement line AT CLIC

    CERN Document Server

    Garcia, H; Blair, G A; Aumeyr, T; Schulte, D; Stulle, F

    2011-01-01

    A precise measurement of the transverse beam size and beam emittances upstream of the final focus is essential for ensuring the full luminosity at future linear colliders. A scheme for the emittance measurements at the RTML line of the CLIC using laser-wire beam profile monitors is described. A lattice of the measurement line is discussed and results of simulations of statistical errors and of their impact on the accuracy of the emittance reconstruction are given. Laser wire systems suitable for CLIC and their main characteristics are discussed.

  18. Results from some anode wire aging tests

    Energy Technology Data Exchange (ETDEWEB)

    Juricic, I.; Kadyk, J.A.

    1986-01-01

    Using twin setups to test anode wire aging in small gas avalanche tubes, a variety of different gas mixtures were tried and other parameters were varied to study their effects upon the gain drop, nomalized to charge transfer: - 1/Q dI/I. This was found to be quite sensitive to the purity of the gases, and also sensitive to the nominal gain and the gas flow rate. The wire surface material can also significantly affect the aging, as can additives, such as ethanol or water vapor. Certain gas mixtures have been found to be consistent with zero aging at the sensitivity level of this technique.

  19. Quantum conductance in silicon quantum wires

    CERN Document Server

    Bagraev, N T; Klyachkin, L E; Malyarenko, A M; Gehlhoff, W; Ivanov, V K; Shelykh, I A

    2002-01-01

    The results of investigations of electron and hole quantum conductance staircase in silicon quantum wires are presented. The characteristics of self-ordering quantum wells of n- and p-types, which from on the silicon (100) surface in the nonequilibrium boron diffusion process, are analyzed. The results of investigations of the quantum conductance as the function of temperature, carrier concentration and modulation degree of silicon quantum wires are given. It is found out, that the quantum conductance of the one-dimensional channels is observed, for the first time, at an elevated temperature (T >= 77 K)

  20. A FLYING WIRE SYSTEM IN THE AGS.

    Energy Technology Data Exchange (ETDEWEB)

    HUANG,H.; BUXTON,W.; MAHLER,G.; MARUSIC,A.; ROSER,T.; SMITH,G.; SYPHERS,M.; WILLIAMS,N.; WITKOVER,R.

    1999-03-29

    As the AGS prepares to serve as the injector for RHIC, monitoring and control of the beam transverse emittance become a major and important topic. Before the installation of the flying wire system, the emittance was measured with ionization profile monitors in the AGS, which require correction for space charge effects. It is desirable to have a second means of measuring profile that is less depend on intensity. A flying wire system has been installed in the AGS recently to perform this task. This paper discusses the hardware and software setup and the capabilities of the system.

  1. EDITORIAL More than a wire More than a wire

    Science.gov (United States)

    Demming, Anna

    2010-10-01

    Nanowires are the natural evolution of the connections in circuits when scaled down to nanometre sizes. On closer inspection, of course, the role of nanowires in developing new technologies is much more than just a current-bearing medium. By sizing the diameters of these objects down to the nanoscale, their properties become increasingly sensitive to factors such as the gas composition, temperature and incident light of their surrounding environment, as well as defects and variations in diameter. What becomes important in modern electronics innovations is not just what is connected, but how. Nanowires had already begun to attract the attention of researchers in the early 1990s as advances in imaging and measurement devices invited researchers to investigate the properties of these one-dimensional structures [1, 2]. This interest has sparked ingenious ways of fabricating nanowires such as the use of a DNA template. A collaboration of researchers at Louisiana Tech University in the US hs provided an overview of various methods to assemble conductive nanowires on a DNA template, including a summary of different approaches to stretching and positioning the templates [3]. Work in this area demonstrates a neat parallel for the role of DNA molecules as the building blocks of life and the foundations of nanoscale device architectures. Scientists at HP Labs in California are using nanowires to shrink the size of logic arrays [4]. One aspect of electronic interconnects that requires particular attention at nanoscale sizes is the effect of defects. The researchers at HP Labs demonstrate that their approach, which they name FPNI (field-programmable nanowire interconnect), is extremely tolerant of the high defect rates likely to be found in these nanoscale structures, and allows reduction in size and power without significantly sacrificing the clock rate. Another issue in scaling down electronics is the trend for an increasing resistivity with decreasing wire width. Researchers

  2. Flow gradient corrections on hot-wire measurements using an X-wire probe

    Science.gov (United States)

    Gooden, J. H. M.; van Lent, M.

    A method has been developed to correct hot-wire measurements by means of a single X-wire probe for the effect of gradients normal to the plane of the wires in the mean flow velocities as well as in the turbulence intensities. Dataprocessing is performed in an iterative way, using the results of measurements with different probe rolling angles, to determine the gradient corrections along the traverse from the previous loop. The method has been applied to measurements in the wake above the trailing edge flap of a wing and it is shown that substantial improvements in the results have been achieved.

  3. Constant-temperature hot-wire anemometer practice in supersonic flows. II - The inclined wire

    Science.gov (United States)

    Smits, A. J.; Muck, K. C.

    1983-01-01

    The performance of a constant-temperature inclined hot-wire in a supersonic flow is critically examined. It is shown that calibration techniques applicable to subsonic flow, such as the cosine cooling law cannot be used when the flow is supersonic. Calibration and measurement procedures appropriate to supersonic flow are suggested, together with the possible limits on their validity. Experimental results for different wires indicate that the sensitivities do not seem to depend on flow direction according to any simple correlation. When the sensitivity exhibits a strong dependence on flow direction, the wire should be discarded to avoid errors due to nonlinear effects.

  4. Tension pneumoperitoneum complicated with tension pneumothorax in a patient with diaphragmatic eventration

    Science.gov (United States)

    Akoglu, Haldun; Coban, Erkan; Guneysel, Ozlem

    2012-01-01

    Tension pneumothorax complicating a pneumoperitoneum is a rare but known entity. However, all previously published articles report an air leak through defects in the diaphragm connecting the pneumoperitoneum and the pneumothorax. Here, the case of a 36-year-old man in whom the pneumoperitoneum acted like a tension pneumothorax because of a congenital eventration of the left diaphragm without penetration is presented. Emergency needle decompression of the abdomen was performed. A gastric ulcer that had passed through the diaphragm to the right lung was diagnosed intraoperatively. Unfortunately, the patient developed a ventricular fibrillation that remained resistant to all resuscitative efforts, and the patient died shortly afterwards. PMID:22604199

  5. Temperature characteristics analysis of HIV partial disconnection wire

    Science.gov (United States)

    Lee, Dae-Dong; Shim, Jae-Myung; Lee, Yu-Sung; Jeong, Yun-Mi; Kim, Young-Dal

    2015-09-01

    Electric fires are caused mainly due to short circuits, overloads, and electric leakage. Of the causes, short circuits are caused by deteriorated insulation, poor contacts, and pressure damage. A partially disconnected wire refers to the status in which the wire section is partially cut, thus reducing the contact area compared to the normal state. Causes of partially disconnected wires, e.g., poor wire contacts and pressure damage, occur mostly in the wiring and in the device's contact area, and they locally increase the resistance, thus triggering thermal changes. Thus, this study simulated damage to a 450/750 V heat-resistant polyvinyl-chloride-insulated (HIV) wire used for preventing electric fires and analyzed the temperature characteristics of normal wires and partially disconnected wires.

  6. Ultrasonic drawing of tungsten wire for incandescent lamps production.

    Science.gov (United States)

    Mordyuk, B N; Mordyuk, V S; Buryak, V V

    2004-04-01

    An influence of ultrasonic treatment (drawing) on structure, high temperature durability, evaporation and creep behaviours of tungsten single crystal and wires were investigated. A relation of tungsten wires properties with dislocation distribution was determined.

  7. Use of miniature, single-wire, sheathed thermocouples

    Science.gov (United States)

    Glawe, G. E.; Holanda, R.; Krause, L. N.

    1977-01-01

    Temperature measurement with small thermocouples is improved by device. Each wire is sheathed separately which increases the interelement insulation by factor of 2 1/2. Each wire in its separate sheath can be brought to junction by independent paths.

  8. STRUCTURE AND CHARACTERISTICS OF PATENTED HIGH-CARBON WIRE

    Directory of Open Access Journals (Sweden)

    A. Ju. Borisenko

    2011-01-01

    Full Text Available The influence of bainite structure on mechanical characteristics of wire of steel 80 after patenting is studied. The quantity and structure state of bainite, providing high complex of mechanical characteristics of high-carbon wire, is determined.

  9. Resistance of a Wire as a Function of Temperature.

    Science.gov (United States)

    Henry, David

    1995-01-01

    Presents a simple experiment that enables students to get a quantitative measure of the relationship between the resistance of a wire and the temperature of the wire allowing the calculation of the temperature coefficient of resistance. (JRH)

  10. Spectroscopic properties of colloidal indium phosphide quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lin-Wang; Wang, Fudong; Yu, Heng; Li, Jingbo; Hang, Qingling; Zemlyanov, Dmitry; Gibbons, Patrick C.; Wang, Lin-Wang; Janes, David B.; Buhro, William E.

    2008-07-11

    Colloidal InP quantum wires are grown by the solution-liquid-solid (SLS) method, and passivated with the traditional quantum dots surfactants 1-hexadecylamine and tri-n-octylphosphine oxide. The size dependence of the band gaps in the wires are determined from the absorption spectra, and compared to other experimental results for InP quantum dots and wires, and to the predictions of theory. The photoluminescence behavior of the wires is also investigated. Efforts to enhance photoluminescence efficiencies through photochemical etching in the presence of HF result only in photochemical thinning or photo-oxidation, without a significant influence on quantum-wire photoluminescence. However, photo-oxidation produces residual dot and rod domains within the wires, which are luminescent. The results establish that the quantum-wire band gaps are weakly influenced by the nature of the surface passivation, and that colloidal quantum wires have intrinsically low photoluminescence efficiencies.

  11. Spectroscopic properties of colloidal indium phosphide quantum wires.

    Science.gov (United States)

    Wang, Fudong; Yu, Heng; Li, Jingbo; Hang, Qingling; Zemlyanov, Dmitry; Gibbons, Patrick C; Wang, Lin-Wang; Janes, David B; Buhro, William E

    2007-11-21

    Colloidal InP quantum wires are grown by the solution-liquid-solid (SLS) method, and passivated with the traditional quantum dots surfactants 1-hexadecylamine and tri-n-octylphosphine oxide. The size dependence of the band gaps in the wires are determined from the absorption spectra, and compared to other experimental results for InP quantum dots and wires, and to the predictions of theory. The photoluminescence behavior of the wires is also investigated. Efforts to enhance photoluminescence efficiencies through photochemical etching in the presence of HF result only in photochemical thinning or photooxidation, without a significant influence on quantum-wire photoluminescence. However, photooxidation produces residual dot and rod domains within the wires, which are luminescent. The results establish that the quantum-wire band gaps are weakly influenced by the nature of the surface passivation and that colloidal quantum wires have intrinsically low photoluminescence efficiencies.

  12. Radiation of relativistic electrons in a periodic wire structure

    Energy Technology Data Exchange (ETDEWEB)

    Soboleva, V.V., E-mail: sobolevaveronica@mail.ru; Naumenko, G.A.; Bleko, V.V.

    2015-07-15

    We present in this work the experimental investigation of the interaction of relativistic electron field with periodic wire structures. We used two types of the targets in experiments: flat wire target and sandwich wire target that represent the right triangular prism. The measurements were done in millimeter wavelength region (10–40 mm) on the relativistic electron beam with energy of 6.2 MeV in far-field zone. We showed that bunched electron beam passing near wire metamaterial prism generates coherent Cherenkov radiation. The experiments with flat wire target were carried out in two geometries. In the first geometry the electron beam passed close to the flat wire target surface. In the second case the electron beam passed through the flat wire structure with generation of a coherent backward transition radiation (CBTR). The comparison of the Cherenkov radiation intensity and BTR intensity from the flat wire target and from the flat conductive target (conventional BTR) was made.

  13. STRUCTURE AND PROPERTIES OF PATENTED HIGH-CARBON WIRE

    Directory of Open Access Journals (Sweden)

    A. Yu. Borisenko

    2012-01-01

    Full Text Available The influence of bainite structure on mechanical characteristics of wire of steel 80 after patenting is studied. The quantity and structure state of bainite, providing high complex of mechanical characteristics of high-carbon wire, is determined.

  14. Development of Stretched wire measurement bench at IDDL, DAVV Indore

    Science.gov (United States)

    Gehlot, Mona; Mishra, G.

    2016-10-01

    A stretched wire magnetic measurement bench is under development at IDDL, DAVV, Indore. In this method a multistrend wire consisting of N turns is stretched inside the undulator to measure the field integrals of the undulators. The wire moved with constant velocity of translation measures the first integral of the undulator field. The cross motion of the wire at the undulator ends measures the second field integral. The measurement accuracy depends on the wire conditions and material properties. In this paper we follow an analytical approach to find the voltage fluctuations due to wire vibrations during the field measurement. It is shown that the voltage fluctuations depend on undulator gap, magnitude of the impulse on the wire. The mass density and the length of the wire also cause sizeable voltage fluctuations. The analytical derived expression is analysed to optimize system parameters for minimum errors during the measurement.

  15. Divergence of the point tension at wetting

    Science.gov (United States)

    Abraham, D. B.; Latrémolière, F.; Upton, P. J.

    1993-07-01

    To determine the behavior of the line-point tension τ^ at the wetting transition, we consider a two-dimensional Ising model with appropriate boundary conditions and investigate suitable definitions of τ^ associated with the junction of an interface tilted with average angle θc and another lying along the substrate. Size-dependent fluctuations in the point of contact require that τ^ be defined through a convolution sum. Hence τ^~=ln(1/θc) as θc-->0 (wetting transition), which can be understood as a consequence of the entropic repulsion of the tilted part of the interface against the substrate.

  16. Surface Tension Driven Convection Experiment Completed

    Science.gov (United States)

    Jacobson, Thomas P.; Sedlak, Deborah A.

    1997-01-01

    The Surface Tension Driven Convection Experiment (STDCE) was designed to study basic fluid mechanics and heat transfer on thermocapillary flows generated by temperature variations along the free surfaces of liquids in microgravity. STDCE first flew on the USML-1 mission in July 1992 and was rebuilt for the USML-2 mission that was launched in October 1995. This was a collaborative project with principal investigators from Case Western Reserve University (CWRU), Professors Simon Ostrach and Yasuhiro Kamotani, along with a team from the NASA Lewis Research Center composed of civil servants and contractors from Aerospace Design & Fabrication, Inc. (ADF), Analex, and NYMA, Inc.

  17. Evaluating the Gradient of the Thin Wire Kernel

    Science.gov (United States)

    Wilton, Donald R.; Champagne, Nathan J.

    2008-01-01

    Recently, a formulation for evaluating the thin wire kernel was developed that employed a change of variable to smooth the kernel integrand, canceling the singularity in the integrand. Hence, the typical expansion of the wire kernel in a series for use in the potential integrals is avoided. The new expression for the kernel is exact and may be used directly to determine the gradient of the wire kernel, which consists of components that are parallel and radial to the wire axis.

  18. Nonlinear theory of a hot-wire anemometer

    Science.gov (United States)

    Betchov, R

    1952-01-01

    A theoretical analysis is presented for the hot-wire anemometer to determine the differences in resistance characteristics as given by King's equation for an infinite wire length and those given by the additional considerations of (a) a finite length of wire with heat loss through its ends and (b) heat loss due to a nonlinear function of the temperature difference between the wire and the air.

  19. Noradrenaline-induced increases in calcium and tension in skeletal muscle conductance and resistance arteries from rats with post-infarction heart failure.

    Science.gov (United States)

    Trautner, Simon; Amtorp, Ole; Boesgaard, Soren; Andersen, Claus B; Galbo, Henrik; Haunsoe, Stig; Sheykhzade, Majid

    2006-05-10

    We tested the hypothesis that arterial reactivity to noradrenaline is augmented in congestive heart failure (CHF), which could contribute to the deleterious changes in peripheral vascular resistance and compliance in this condition. From male Wistar rats with post-infarction CHF and sham-operated rats, skeletal muscle conductance and resistance arteries (mean lumen diameters: 514 and 186 microm) were isolated and mounted on wire myographs, and wall tension was recorded in response to cumulative application of acetylcholine and noradrenaline to the vessel segments. In a subset of experiments, wall tension and cytosolic free calcium ion concentration [Ca(2+)](i) were recorded simultaneously during noradrenaline application, using wire myography and the FURA-2 technique. No significant differences were found in the arterial baseline levels of [Ca(2+)](i) or tension between CHF and sham rats. In the resistance arteries of CHF rats, the noradrenaline-induced increases in [Ca(2+)](i) were significantly enhanced (P=0.003). Despite the augmented [Ca(2+)](i) levels, the tension responses to noradrenaline were unaltered in these arteries. In the conductance arteries, there were no significant differences in noradrenaline-induced [Ca(2+)](i) or tension responses between CHF and control rats. CHF did not alter vascular morphology or change vascular relaxations to acetylcholine in either type of artery. In conclusion, these results do not support the contention that arterial reactivity to noradrenaline is augmented in the skeletal muscle vascular bed in CHF. On the contrary, the unchanged contractile responsiveness in the resistance arteries despite the enhanced levels of [Ca(2+)](i) during noradrenaline application suggests that the contractile function of these vessels is compromised in CHF. Neither vascular remodeling, endothelial dysfunction nor changes in baseline vascular tone could be demonstrated in the skeletal muscle vascular bed of this animal model of heart failure.

  20. Numerical Simulation of Wire-Coating

    DEFF Research Database (Denmark)

    Wapperom, Peter; Hassager, Ole

    1999-01-01

    A finite element program has been used to analyze the wire-coating process of an MDPE melt. The melt is modeled by a nonisothermal Carreau model. The emphasis is on predicting an accurate temperature field. Therefore, it is necessary to include the heat conduction in the metal parts. A comparison...

  1. Welding Wires To Thin Thermocouple Films

    Science.gov (United States)

    Holanda, Raymond; Kim, Walter S.; Danzey, Gerald A.; Pencil, Eric; Wadel, Mary

    1993-01-01

    Parallel-gap resistance welding yields joints surviving temperatures of about 1,000 degrees C. Much faster than thermocompression bonding. Also exceeds conductive-paste bonding and sputtering thin films through porous flame-sprayed insulation on prewelded lead wires. Introduces no foreign material into thermocouple circuit and does not require careful control of thickness of flame-sprayed material.

  2. Phase Slips in Topological Superconductor Wire Devices

    Science.gov (United States)

    Goldberg, Samuel; Bergman, Doron; Pekker, David; Refael, Gil

    2012-02-01

    We make a detailed study of phase slips in topological superconducting wires and devices based on topological wires. We begin by investigating a device composed of a topological superconducting wire connected to a non-topological wire (T-S). In the T-segment only slips of the phase by multiples of 4π are allowed, while in the S-segment slips by 2π are also allowed. We show that near the interface, 2π phase slips are also allowed and we comment on the consequences of such phase slips for the Aharonov-Casher effect. We also consider an implementation of a q-bit consisting of a T-S-T device, where the quantum information is stored in the parity of the two topological segments via the four Majorana modes. We show that the central S-segment of this type of device can support 2π phase-slips which result in the decoherence of the q-bit.

  3. Wire chamber degradation at the Argonne ZGS

    Energy Technology Data Exchange (ETDEWEB)

    Haberichter, W.; Spinka, H.

    1986-01-01

    Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM.

  4. Brain Wiring in the Fourth Dimension.

    Science.gov (United States)

    Wernet, Mathias F; Desplan, Claude

    2015-07-02

    In this issue of Cell, Langen et al. use time-lapse multiphoton microscopy to show how Drosophila photoreceptor growth cones find their targets. Based on the observed dynamics, they develop a simple developmental algorithm recapitulating the highly complex connectivity pattern of these neurons, suggesting a basic framework for establishing wiring specificity.

  5. Studying superconducting Nb3Sn wire

    CERN Multimedia

    AUTHOR|(CDS)2099575

    2015-01-01

    Studying superconducting Nb3Sn wire. From the current experience from LHC and HL-LHC we know that the performance requirements for Nb3Sn conductor for future circular collider are challenging and should exceed that of present state-of-the-art materials.

  6. Tunable permeability of magnetic wires at microwaves

    Energy Technology Data Exchange (ETDEWEB)

    Panina, L.V., E-mail: lpanina@plymouth.ac.uk [National University of Science and Technology, MISiS, Moscow (Russian Federation); Institute for Design Problems in Microelectronics, RAN, Moscow (Russian Federation); Makhnovskiy, D.P. [School of Computing and Mathematics, University of Plymouth (United Kingdom); Morchenko, A.T.; Kostishin, V.G. [National University of Science and Technology, MISiS, Moscow (Russian Federation)

    2015-06-01

    This paper presents the analysis into microwave magnetic properties of magnetic microwires and their composites in the context of applications in wireless sensors and tunable microwave materials. It is demonstrated that the intrinsic permeability of wires has a wide frequency dispersion with relatively large values in the GHz band. In the case of a specific magnetic anisotropy this results in a tunable microwave impedance which could be used for distributed wireless sensing networks in functional composites. The other range of applications is related with developing the artificial magnetic dielectrics with large and tunable permeability. The composites with magnetic wires with a circumferential anisotropy have the effective permeability which differs substantially from unity for a relatively low concentration (less than 10%). This can make it possible to design the wire media with a negative and tunable index of refraction utilising natural magnetic properties of wires. - Highlights: • Applications of magnetic microwires for functional composites and distributed sensor networks are proposed. • Diluted composites with magnetic microwires can demonstrate tunable left-handed properties. • Large microwave permeability combined with a specific magnetic structure lead to a large and sensitive microwave magnetoimpedance. • Microwave magnetoimpedance highly sensitive to temperature is demonstrated.

  7. 77 FR 1504 - Stainless Steel Wire Rod From India

    Science.gov (United States)

    2012-01-10

    ... COMMISSION Stainless Steel Wire Rod From India Determination On the basis of the record \\1\\ developed in the... antidumping duty order on stainless steel wire rod From India would be likely to lead to continuation or... contained in USITC Publication 4300 (January 2012), entitled Stainless Steel Wire Rod From...

  8. Lunar Module Wiring Design Considerations and Failure Modes

    Science.gov (United States)

    Interbartolo, Michael

    2009-01-01

    This slide presentation reviews the considerations for the design of wiring for the Lunar Module. Included are a review of the choice of conductors and insulations, the wire splicing (i.e., crimping, and soldering), the wire connectors, and the fabrication of the wire harnesses. The problems in fabrication include the wires being the wrong length, the damage due to the sharp edges, the requried use of temproary protective covers and inadequate training. The problems in the wire harness installation include damge from sharp eges, work on adjacent harnesses, connector damage, and breaking wires. Engineering suggestions from the Apollo-era in reference to the conductors that are reviewed include: the use of plated conductors, and the use of alloys for stronger wiring. In refernce to insulation, the suggestions from Apollo era include the use of polymer tape-wrap wire insulation due to the light weight, however, other types of modern insulation might be more cost-effective. In reference to wire splices and terminal boards the suggestions from the Apollo Era include the use of crimp splices as superior to solder splices, joining multiple wire to a common point using modular plug-ins might be more reliable, but are heavier than crimp splicing. For connectors, the lessons from the Apollo era indicate that a rear environmental seal that does not require additional potting is preferred, and pins should be crimped or welded to the incoming wires and be removable from the rear of the connector.

  9. Thermal Aware Floorplanning Incorporating Temperature Dependent Wire Delay Estimation

    DEFF Research Database (Denmark)

    Winther, AndreasThor; Liu, Wei; Nannarelli, Alberto

    2015-01-01

    Temperature has a negative impact on metal resistance and thus wire delay. In state-of-the-art VLSI circuits, large thermal gradients usually exist due to the uneven distribution of heat sources. The difference in wire temperature can lead to performance mismatch because wires of the same length ...

  10. Integrating the Gradient of the Thin Wire Kernel

    Science.gov (United States)

    Champagne, Nathan J.; Wilton, Donald R.

    2008-01-01

    A formulation for integrating the gradient of the thin wire kernel is presented. This approach employs a new expression for the gradient of the thin wire kernel derived from a recent technique for numerically evaluating the exact thin wire kernel. This approach should provide essentially arbitrary accuracy and may be used with higher-order elements and basis functions using the procedure described in [4].When the source and observation points are close, the potential integrals over wire segments involving the wire kernel are split into parts to handle the singular behavior of the integrand [1]. The singularity characteristics of the gradient of the wire kernel are different than those of the wire kernel, and the axial and radial components have different singularities. The characteristics of the gradient of the wire kernel are discussed in [2]. To evaluate the near electric and magnetic fields of a wire, the integration of the gradient of the wire kernel needs to be calculated over the source wire. Since the vector bases for current have constant direction on linear wire segments, these integrals reduce to integrals of the form

  11. Low-Inductance Wiring For Parallel Switching Transistors

    Science.gov (United States)

    Veatch, M. S.; Landis, D. M.

    1990-01-01

    Simple configuration for wiring of multiple parallel-connected switching transistors minimizes stray wiring inductance while providing for use of balancing transformers, which equalize currents in transistors. Currents balanced on twisted pairs of wires. Because twisted pairs carry both "hot-side" and return currents, this configuration has relatively low inductance.

  12. 30 CFR 57.12012 - Bare signal wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bare signal wires. 57.12012 Section 57.12012 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... and Underground § 57.12012 Bare signal wires. The potential on bare signal wires accessible to contact...

  13. 30 CFR 56.12012 - Bare signal wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bare signal wires. 56.12012 Section 56.12012 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Bare signal wires. The potential on bare signal wires accessible to contact by persons shall not exceed...

  14. 78 FR 7452 - Steel Wire Garment Hangers From Vietnam; Determinations

    Science.gov (United States)

    2013-02-01

    ... COMMISSION Steel Wire Garment Hangers From Vietnam; Determinations On the basis of the record \\1\\ developed... imports of steel wire garment hangers from Vietnam, provided for in subheading 7326.20.00 of the... countervailing and antidumping duty orders on steel wire garment hangers from Vietnam. Background The...

  15. 77 FR 72884 - Steel Wire Garment Hangers From Taiwan

    Science.gov (United States)

    2012-12-06

    ... COMMISSION Steel Wire Garment Hangers From Taiwan Determination On the basis of the record \\1\\ developed in... the United States is materially injured by reason of imports of steel wire garment hangers from Taiwan... wire garment hangers from Taiwan were dumped within the meaning of 733(b) of the Act (19 U.S.C....

  16. Quantum stability and magic lengths of metal atom wires

    Science.gov (United States)

    Cui, Ping; Choi, Jin-Ho; Lan, Haiping; Cho, Jun-Hyung; Niu, Qian; Yang, Jinlong; Zhang, Zhenyu

    2016-06-01

    Metal atom wires represent an important class of nanomaterials in the development of future electronic devices and other functional applications. Using first-principles calculations within density functional theory, we carry out a systematic study of the quantum stability of freestanding atom wires consisting of prototypical metal elements with s -, s p -, and s d -valence electrons. We explore how the quantum mechanically confined motion and local bonding of the valence electrons in these different wire systems can dictate their overall structural stability and find that the formation energy of essentially all the wires oscillates with respect to their length measured by the number n of atoms contained in the wires, establishing the existence of highly preferred (or magic) lengths. Furthermore, different wire classes exhibit distinctively different oscillatory characteristics and quantum stabilities. Alkali metal wires possessing an unpaired s valence electron per atom exhibit simple damped even-odd oscillations. In contrast, Al and Ga wires containing three s2p1 valence electrons per atom generally display much larger and undamped even-odd energy oscillations due to stronger local bonding of the p orbitals. Among the noble metals, the s -dominant Ag wires behave similarly to the linear alkali metal wires, while Au and Pt wires distinctly prefer to be structurally zigzagged due to strong relativistic effects. These findings are discussed in connection with existing experiments and should also be instrumental in future experimental realization of different metal atom wires in freestanding or supported environments with desirable functionalities.

  17. 77 FR 28404 - Galvanized Steel Wire From China and Mexico

    Science.gov (United States)

    2012-05-14

    ... COMMISSION Galvanized Steel Wire From China and Mexico Determinations On the basis of the record \\1... retarded, by reason of imports from Mexico of galvanized steel wire, provided for in subheadings 7217.20.30... galvanized steel wire from China and Mexico were sold at LTFV within the meaning of 733(b) of the Act (19...

  18. 76 FR 29266 - Galvanized Steel Wire From China and Mexico

    Science.gov (United States)

    2011-05-20

    ... COMMISSION Galvanized Steel Wire From China and Mexico Determinations On the basis of the record \\1... injured by reason of imports from China and Mexico of galvanized steel wire, provided for in subheading... subsidized imports of galvanized steel wire from China and Mexico. Accordingly, effective March 31, 2011,...

  19. A laser-wire system for the International Linear Collider

    Indian Academy of Sciences (India)

    Nicolas Delerue; Sudhir Dixit; Fred Gannaway; David Howell; Myriam Qurshi; Grahame Blair; Stewart Boogert; Gary Boorman; Chafik Driouichi; Lawerence Deacon; Alexander Aryshev; Pavel Karataev; Nobuhiro Terunnuma; Junji urakawa; Axel Brachmann; Joe Frisch; Marc Ross

    2007-12-01

    A new laser-wire has been installed in the extraction line of the ATF at KEK. It aims at demonstrating that laser-wires can be used to measure micrometre scale beam size. In parallel, studies have been made to specify a laser suitable for the ILC laser-wires.

  20. Hot-Wire Probe for Compressible Subsonic Flow

    Science.gov (United States)

    Stainback, P. C.; Johnson, C. B.; Basnett, C. B.

    1985-01-01

    Probe measures velocity, density, and total temperature fluctuations. Three-wire probe used with each wire operating at different overheat ratio. Technique extendable into transonic and low supersonic flow regimes without difficulty except for those problems usually associated with lengthy calibration and possible wire breaking.

  1. Thermal conductivity modeling of circular-wire nanocomposites

    Science.gov (United States)

    Hsieh, Tse-Yang; Yang, Jaw-Yen

    2010-08-01

    A phonon Boltzmann equation solver using multiblock-structured grid system is developed and applied to study transverse thermal transport in silicon-germanium circular-wire nanocomposite (silicon nanowires embedded in germanium host matrix). Past studies usually assume geometric simplification for the circular-wire nanocomposite, so the heat transfer is actually modeled in a square-wire nanocomposite. To demonstrate geometry effect, phonon transport in both the circular-wire and square-wire nanocomposites are investigated with various wire spacings, volume fractions, and dimensions. In ballistic phonon transport, due to the smoothness of circular shape, the circular wire imposes less thermal resistance than the square wire. Nevertheless, in the geometric simplification, the wire spacing of the square-wire nanocomposite is larger than that of the circular-wire nanocomposite. The usual geometric simplification can overestimate the thermal conductivity of the circular-wire nanocomposite. The obtained results can provide essential information for the development of bulk-nanostructured thermoelectric devices.

  2. 21 CFR 872.4880 - Intraosseous fixation screw or wire.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraosseous fixation screw or wire. 872.4880... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4880 Intraosseous fixation screw or wire. (a) Identification. An intraosseous fixation screw or wire is a metal device intended to be...

  3. A Laser-Wire System for the International Linear Collider

    Energy Technology Data Exchange (ETDEWEB)

    Delerue, N.; Dixit, S.; Gannaway, F.; Howell, D.; Qurshi, M.; Blair, G.; Boogert, S.; Boorman, G.; Driouichi, C.; Deacon, L.; Aryshev, A.; Karataev, P.; Terunuma, N.; Urakawa, J.; Brachmann, A.; Frisch, J.; Ross, M.; /Oxford U. /Royal Holloway, U. of London /KEK, Tsukuba /SLAC

    2009-04-30

    A new laser-wire has been installed in the extraction line of the ATF at KEK. It aims at demonstrating that laser-wires can be used to measure micrometre scale beam size. In parallel, studies have been made to specify a laser suitable for the ILC laser-wires.

  4. Corrosion behavior of titanium wires: An in vitro study

    Directory of Open Access Journals (Sweden)

    Thakur Prasad Chaturvedi

    2012-01-01

    Results: The results showed degradation of titanium wires by electrochemical attack when they were placed in the hostile electrolytic environments provided in the experiments. Surface analysis of titanium wires showed pitting and localized attacks on the surface. Pitting corrosion was found in the titanium wires.

  5. THERMO-MECHANICALLY PROCESSED ROLLED WIRE FOR HIGH

    Directory of Open Access Journals (Sweden)

    V. A. Lutsenko

    2012-01-01

    Full Text Available It is shown that at twisting of wire of diameter 1,83 mm, produced by direct wire drawing of thermomechanically processed rolled wire of diameter 5,5 mm of steel 90, metal stratification is completely eliminated at decrease of carbon, manganese and an additional alloying of chrome.

  6. Kirschner Wires : insertion techniques and bone related consequences

    NARCIS (Netherlands)

    Franssen, B.B.G.M.

    2010-01-01

    The Kirschner (K-) wire was first introduced in 1909 by Martin Kirschner. This is a thin unthreaded wire of surgical steel with a diameter of up to three millimeters and a selection of different tips. The use of K-wires is often promoted as a simple technique because of its easy placement, cost-effe

  7. 30 CFR 77.701-3 - Grounding wires; capacity.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity. 77.701-3 Section 77.701-3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... MINES Grounding § 77.701-3 Grounding wires; capacity. Where grounding wires are used to ground...

  8. 24 CFR 3280.814 - Painting of wiring.

    Science.gov (United States)

    2010-04-01

    ... wires, as the color coding may be obliterated by the paint. ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Painting of wiring. 3280.814... Painting of wiring. During painting or staining of the manufactured home, it shall be permitted to...

  9. Percutaneous Kirschner wire (K-wire) fixation for humerus shaft fractures in children: A treatment concept

    OpenAIRE

    2013-01-01

    Background: Fractures of the humeral shaft are uncommon, representing less than 10 percent of all fractures in children. Humeral shaft fractures in children can be treated by immobilisation alone. A small number of fractures are unable to be reduced adequately or maintained in adequate alignment, and these should be treated surgically. In the present study, Kirschner wires (K-wire) were used to achieve a closed intramedullary fixation of humeral shaft fractures. The objective of this study wa...

  10. An interconnecting bus power optimization method combining interconnect wire spacing with wire ordering

    Institute of Scientific and Technical Information of China (English)

    Zhu Zhang-Ming; Hao Bao-Tian; En Yun-Fei; Yang Yin-Tang; Li Yue-Jin

    2011-01-01

    On-chip interconnect buses consume tens of percents of dynamic power in a nanometer scale integrated circuit and they will consume more power with the rapid scaling down of technology size and continuously rising clock frequency,therefore it is meaningful to lower the interconnecting bus power in design. In this paper, a simple yet accurate interconnect parasitic capacitance model is presented first and then, based on this model, a novel interconnecting bus optimization method is proposed. Wire spacing is a process for spacing wires for minimum dynamic power, while wire ordering is a process that searches for wire orders that maximally enhance it. The method, i.e., combining wire spacing with wire ordering, focuses on bus dynamic power optimization with a consideration of bus performance requirements.The optimization method is verified based on various nanometer technology parameters, showing that with 50% slack of routing space, 25.71% and 32.65% of power can be saved on average by the proposed optimization method for a globalbus and an intermediate bus, respectively, under a 65-nm technology node, compared with 21.78% and 27.68% of power saved on average by uniform spacing technology. The proposed method is especially suitable for computer-aided designof nanometer scale on-chip buses.

  11. Forecasting of Corrosion Properties of Steel Wires for Production of Guide Wires for Cardiological Treatment

    Directory of Open Access Journals (Sweden)

    J. Przondziono

    2013-01-01

    Full Text Available The study presents evaluation of the influence of strain in drawing process and of surface modification on resistance to electrochemical corrosion of wires made of stainless steel for production of guide wires used in invasive cardiology. The results of static tensile test enabled us to determine the course of flow curve of wires made of X10CrNi 18-8 steel as well as mathematical form of flow stress function. Resistance to electrochemical corrosion was evaluated on the ground of registered anodic polarisation curves by means of potentiodynamic method. The tests were performed in solution simulating human blood on samples that were electrolytically polished and samples that were polished and then chemically passivated. Exemplary anodic polarisation curves were given. It was proved that with the applied strain, corrosion properties decrease. It was found that chemical passivation improves wire corrosion characteristics. Statistical analysis showed that there is a significant dependence between corrosion properties (polarisation resistance Rp and strain ε applied in drawing process. Functions that present the change Rp=f(ε were selected. The issue is of importance to guide wire manufacturers because application of the suggested methodology will enable us to forecast corrosion characteristics of wire with the required strength drawn with the applied strain.

  12. Research regarding wires elastic deformations influence on joints positioning of a wire-driven robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-08-01

    In this paper, we present the influence of driving wires deformation on positioning precision of joints from an elephant's trunk robotic arm. Robotic arms driven by wires have the joint accuracy largely depending on wires rigidity. The joint moment of resistance causes elastic deformation of wires and it is determined by: manipulated object load, weight loads previous to the analyzed joint and inherent resistance moment of joint. Static load analysis emphasizes the particular wires elastic deformation of each driven joint from an elephant's trunk robotic arm with five degrees of freedom. We consider the case of a constant manipulated load. Errors from each driving system of joints are not part of the closed loop system. Thus, precision positioning depends on wires elastic deformation which is about microns and causes angle deviation of joints about tens of minutes of sexagesimal degrees. The closer the joints to base arm the smaller positioning precision of joint. The obtained results are necessary for further compensation made by electronic corrections in the programming algorithm of the elephant's trunk robotic arm to improve accuracy.

  13. Theoretical and experimental study on surface tension and dynamic surface tension of aqueous lithium bromide and water with additive

    Institute of Scientific and Technical Information of China (English)

    程文龙; 陈则韶; 秋泽淳; 胡芃; 柏木孝夫

    2003-01-01

    The surface tensions of water and aqueous lithium bromide (LiBr) with 2-ethyl-1-hexa- nol (2EH) and 1-octanol were measured using Wilhelmy plate method, and the oscillation of surface tension under the open condition for LiBr solution was observed. The dynamic surface tensions of water and LiBr solution in the presence of the 2EH and 1-octanol vapor were measured in this paper. The results showed that the additives vapor could obviously affect surface tension. For water, the dynamic surface tension was also affected by the mass of the tested liquid; however, for LiBr solution, the dynamic surface tension was not related to the mass of the tested solution. According to the experimental results, the hypothesis that surface tension varies linearly with the surface excess concentration is advanced, which could overcome the limit of Gibbs equation. The equations of surface absorption and desorption are modified, the units of the adsorption coefficient and desorption coefficient are unified; the effects of the liquid and vapor of additive on the surface tension are unified; the theoretical relations of the static surface tension and dynamic surface tension with the relative contents of the liquid and vapor of additive are obtained under the combined actions of them; the theoretical equations are validated by the experiments results.

  14. Tension-type headache: pain, fatigue, tension, and EMG responses to mental activation.

    Science.gov (United States)

    Bansevicius, D; Westgaard, R H; Sjaastad, O M

    1999-06-01

    Twenty patients with tension-type headache (14 chronic and 6 episodic) and 20 group-matched controls were selected for this study. They participated in a 1-hour, complex, two-choice, reaction-time test, as well as 5-minute pretest and 20-minute posttest periods. Subjects reported any pain in the forehead, temples, neck, and shoulders, as well as any feelings of fatigue and tension during the pretest, and every 10 minutes during the test and posttest by visual analog scales. Superficial electromyography was recorded simultaneously from positions representing the frontal and temporal muscles, neck (mostly splenius), and trapezius muscles. The location of pain corresponded to the position of the electrodes, but extended over a larger area. The test provoked pain in the forehead, neck, and shoulders of patients, i.e., pain scores from these regions increased significantly during the test. The pain scores continued to increase posttest. In patients, the EMG response of the trapezius (first 10 minutes of the test) was elevated relative to pretest. In controls, only the frontal muscles showed an EMG test response. Patients showed significantly higher EMG responses than controls in the neck (whole test period) and trapezius (first 10 minutes of the test period). There were significant differences in pain and fatigue scoring between patients and controls in all three periods and in tension scoring posttest. Fatigue correlated with pain, with increasing significance for all locations examined, while tension was mainly associated with the neck pain. The meaning of the variables "tension" and "fatigue" in headache, and their association with recorded muscle activity in various regions is discussed. The EMG response of the trapezius muscle to the test is discussed in comparison with similar responses observed in patients with other pain syndromes.

  15. SPECIFIC FEATURES OF TECHNOLOGY OF MANUFACTURING A ZINC-COATED TUB WIRE FOR MUZZLE (BOTTLE’ HOOD WIRE

    Directory of Open Access Journals (Sweden)

    D. B. Zuev

    2016-01-01

    Full Text Available The paper presents the main technical specifications of galvanized low carbon wire for muzzles (bottle’hood wire, consistent with the exploitation requirements to the wire in the manufacture and use of muzzles. The main criteria when selecting the steel grade and upon selection of the technological processes are given. 

  16. Narrative tension analysis: reader`s and text aspects

    OpenAIRE

    Анна Вениаминовна Лещенко

    2016-01-01

    In this article narrative tension is conceptualized as a complex cognitive and affective phenomenon being analysed in two dimensions: psychological and textological. In the receptive and psychological framework narrative tension is considered as reader`s psychological response to the fictional events of the storyworld. In modern text theory narrative tension is thought as a specific narrative strategy represented by definite narrative structures inducing the particular emotional state of the ...

  17. Narrative tension analysis: reader`s and text aspects

    Directory of Open Access Journals (Sweden)

    Анна Вениаминовна Лещенко

    2016-12-01

    Full Text Available In this article narrative tension is conceptualized as a complex cognitive and affective phenomenon being analysed in two dimensions: psychological and textological. In the receptive and psychological framework narrative tension is considered as reader`s psychological response to the fictional events of the storyworld. In modern text theory narrative tension is thought as a specific narrative strategy represented by definite narrative structures inducing the particular emotional state of the reader

  18. Precision Tension Control System Using Magnetic Particle Clutch

    Institute of Scientific and Technical Information of China (English)

    王春香; 杨汝清; 王永章; 路华

    2004-01-01

    The control of the stability of the filament tension is one of the crucial techniques ensuring the component quality of the composite materials. The open-loop tension control system, with industrial control computer as the core,magnetic particle clutch as the actuator, equipped with compensation technique is researched and manufactured.It can assure the tension control stability of the yarn in filament winding process and increase the control precision of the whole system.

  19. A wire scanning type position monitor for an undulator radiation

    Science.gov (United States)

    Zhang, Xiaowei; Sugiyama, Hiroshi; Ando, Masami; Xia, Shaojian; Shiwaku, Hideaki

    1995-02-01

    A scanning wire position monitor for insertion devices was designed and installed in an x-ray undulator beam line. It consists of a graphite wire, a copper mesh for electric shielding, and a motor-driven linear guide. The wire of the monitor was tested under the undulator radiation thermal load. It has been found that the signal level of the monitor was proportional to the radiation power density on the wire. Even when the wire crossed the beam during the x-ray experiment, no detectable influence on the experiment was observed.

  20. Conductance of a Finite Quantum Wire Connected to Reservoirs

    OpenAIRE

    Liu, Yu-Liang

    1997-01-01

    We study a finite quantum wire connected to external leads, and show that the conductance of the system significantly depends upon the length of the quantum wire and the position of the impurity in it. For a very long quantum wire and the impurity far away from its two ends, the conductance has the same behavior as that for an infinity quantum wire above some very little energy scale. However, for a very short quantum wire, the conductance is independent of the electron-electron interactions ...

  1. Accuracy Of Hot-Wire Anemometry In Supersonic Turbulence

    Science.gov (United States)

    Logan, Pamela; Mckenzie, Robert L.; Bershader, Daniel

    1989-01-01

    Sensitivity of hot-wire probe compared to laser-induced-florescence measurements. Report discusses factors affecting readings of hot-wire anemometer in turbulent supersonic boundary layer. Presents theoretical analysis of responses of hot-wire probe to changes in flow; also compares measurements by hot-wire probe with measurements of same flows by laser-induced fluorescence (LIF). Because LIF provides spatially and temporally resolved data on temperature, density, and pressure, provides independent means to determine responses of hot-wire anemometers to these quantities.

  2. Model of Carbon Wire Heating in Accelerator Beam

    CERN Document Server

    Sapinski, M

    2008-01-01

    A heat flow equation with beam-induced heating and various cooling processes for a carbon wire passing through a particle beam is solved. Due to equation nonlinearity a numerical approach based on discretization of the wire movement is used. Heating of the wire due to the beam-induced electromagnetic field is taken into account. An estimation of the wire sublimation rate is made. The model is tested on SPS, LEP and Tevatron Main Injector data. Results are discussed and conclusions about limits of Wire Scanner operation on LHC beams are drawn.

  3. Size Effect for Normal Strength Concrete in Uniaxial Tension

    Institute of Scientific and Technical Information of China (English)

    李庆斌; 尹玉先

    2004-01-01

    This paper presents a new size effect model for normal strength concrete subjected to uniaxial tension. The model is based on two extremes, sand cement paste in uniaxial tension and a sand-cement-paste/rock interface in uniaxial tension. Uniaxial tension tests with normal strength concrete measuring the tensile strength of normal strength concrete specimens with different geometrical shapes and different ratios of the aggregate size to the characteristic dimension of the concrete specimen show a significant size effect. The theoretical size effect law prediction agrees well with the experimental data.

  4. Bending Under Tension Test with Direct Friction Measurement

    DEFF Research Database (Denmark)

    Andreasen, Jan Lasson; Olsson, David Dam; Chodnikiewicz, K.

    2006-01-01

    A special Bending-Under-Tension (BUT) transducer has been developed in which friction around the tool radius can be directly measured when drawing a plane sheet strip around a cylindrical tool-pin under constant back tension. The front tension, back tension and torque on the tool-pin are all...... measured directly, thus enabling accurate measurement of friction and direct determination of lubricant film breakdown for varying normal pressure, sliding speed, tool radius and tool preheat temperature. The transducer is applied in an experimental investigation focusing on limits of lubrication...... in drawing of stainless steel showing the influence of varying process conditions and the performance of different lubricants....

  5. SpaceWire Plug and Play

    Science.gov (United States)

    Rakow, Glenn; McGuirk, Patrick; Kimmery, Clifford; Jaffe, Paul

    2006-01-01

    The ability to rapidly deploy inexpensive satellites to meet tactical goals has become an important goal for military space systems. In fact, Operationally Responsive Space (ORS) has been in the spotlight at the highest levels. The Office of the Secretary of Defense (OSD) has identified that the critical next step is developing the bus standards and modular interfaces. Historically, satellite components have been constructed based on bus standards and standardized interfaces. However, this has not been done to a degree, which would allow the rapid deployment of a satellite. Advancements in plug-and-play (PnP) technologies for terrestrial applications can serve as a baseline model for a PnP approach for satellite applications. Since SpaceWire (SpW) has become a de facto standard for satellite high-speed (greater than 200Mbp) on-board communications, it has become important for SpW to adapt to this Plug and Play (PnP) environment. Because SpW is simply a bulk transport protocol and lacks built-in PnP features, several changes are required to facilitate PnP with SpW. The first is for Host(s) to figure out what the network looks like, i.e., how pieces of the network, routers and nodes, are connected together; network mapping, and to receive notice of changes to the network. The second is for the components connected to the network to be understood so that they can communicate. The first element, network topology mapping & change of status indication, is being defined (topic of this paper). The second element describing how components are to communicate has been defined by ARFL with the electronic data sheets known as XTEDS. The first element, network mapping, is recent activities performed by Air Force Research Lab (ARFL), Naval Research Lab (NRL), NASA and US industry (Honeywell, Clearwater, FL, and others). This work has resulted in the development of a protocol that will perform the lower level functions of network mapping and Change Of Status (COS) indication

  6. Minimizing RF heating of conducting wires in MRI.

    Science.gov (United States)

    Yeung, Christopher J; Karmarkar, Parag; McVeigh, Elliot R

    2007-11-01

    Performing interventions using long conducting wires in MRI introduces the risk of focal RF heating at the wire tip. Comprehensive EM simulations are combined with carefully measured experimental data to show that method-of-moments EM field modeling coupled with heat transfer modeling can adequately predict RF heating with wires partially inserted into the patient-mimicking phantom. The effects of total wire length, inserted length, wire position in the phantom, phantom position in the scanner, and phantom size are examined. Increasing phantom size can shift a wire's length of maximum tip heating from about a half wave toward a quarter wave. In any event, with wires parallel to the scanner bore, wire tip heating is minimized by keeping the patient and wires as close as possible to the central axis of the scanner bore. At 1.5T, heating is minimized if bare wires are shorter than 0.6 m or between approximately 2.4 m and approximately 3.0 m. Heating is further minimized if wire insertion into phantoms equivalent to most aqueous soft tissues is less than 13 cm or greater than 40 cm (longer for fatty tissues, bone, and lung). The methods demonstrated can be used to estimate the absolute amount of heating in order to set RF power safety thresholds.

  7. Deformation Analysis of Surface Defects in Wire Drawing

    Science.gov (United States)

    Shinohara, Tetsuo; Yoshida, Kazunari

    2004-06-01

    Recently, the high surface quality of drawn wires and rods have been required from the field of automobile and machine. The surface flaw of a drawn wire has big influence on the quality of a product. Using three-dimensional FEA, this study investigates growth of surface defects due to wire drawing when these on wire, wire breaks due to surface defects are common problems in wire drawing. As a cause of a surface flaw, rolling up of a wire rod and the poor handling at the time of conveyance are cited. The authors artificially produced transversal cracks and scratches on the surface of wires, and investigated the growth and disappearance of these cracks during drawing, by three-dimensional FEA and experiments. If drawing out of the wire rod which has a flaw in the wire rod surface is repeated, it will become the check mark which the width of a flaw spreads and is known well in the production site. Furthermore, if drawing out is repeated, the compression stress of the direction of an axis by stress, and will become quite small. However, the crack of the direction of an axis remained and it was shown clearly that quality is affected. Moreover, the influence which the surface treatment of peeling has on a wire rod was also considered.

  8. Solar power wires based on organic photovoltaic materials.

    Science.gov (United States)

    Lee, Michael R; Eckert, Robert D; Forberich, Karen; Dennler, Gilles; Brabec, Christoph J; Gaudiana, Russell A

    2009-04-10

    Organic photovoltaics in a flexible wire format has potential advantages that are described in this paper. A wire format requires long-distance transport of current that can be achieved only with conventional metals, thus eliminating the use of transparent oxide semiconductors. A phase-separated, photovoltaic layer, comprising a conducting polymer and a fullerene derivative, is coated onto a thin metal wire. A second wire, coated with a silver film, serving as the counter electrode, is wrapped around the first wire. Both wires are encased in a transparent polymer cladding. Incident light is focused by the cladding onto to the photovoltaic layer even when it is completely shadowed by the counter electrode. Efficiency values of the wires range from 2.79% to 3.27%.

  9. Metal-wire terahertz time-domain spectroscopy

    Science.gov (United States)

    Walther, Markus; Freeman, Mark R.; Hegmann, Frank A.

    2005-12-01

    Terahertz (THz) pulses propagating on a metal-wire waveguide are used to perform terahertz time-domain spectroscopy of lactose powder dispersed on top of the wire. The THz pulses are generated by a photoconductive switch at one end of the metal wire and are detected at the other end by electro-optic sampling in a ZnTe crystal that can be moved parallel to the axis of the metal wire. A large enhancement in the peak amplitude of the THz signal is observed by contacting the metal wire to one of the electrodes of the photoconductive switch. The propagation characteristics of the THz pulse along the metal wire and near its end are studied. Potential applications of metal-wire terahertz time-domain spectroscopy are discussed.

  10. Investigation of Mechanical Properties of Cryogenically Treated Music Wire

    CERN Document Server

    Heptonstall, A; Robertson, N A

    2015-01-01

    It has been reported that treating music wire (high carbon steel wire) by cooling to cryogenic temperatures can enhance its mechanical properties with particular reference to those properties important for musical performance. We use such wire for suspending many of the optics in Advanced LIGO, the upgrade to LIGO - the Laser Interferometric Gravitational-Wave Observatory. Two properties that particularly interest us are mechanical loss and breaking strength. A decrease in mechanical loss would directly reduce the thermal noise associated with the suspension, thus enhancing the noise performance of mirror suspensions within the detector. An increase in strength could allow thinner wire to be safely used, which would enhance the dilution factor of the suspension, again leading to lower suspension thermal noise. In this article we describe the results of an investigation into some of the mechanical properties of music wire, comparing untreated wire with the same wire which has been cryogenically treated. For th...

  11. Evolving spacetimes with purely radial tension

    Directory of Open Access Journals (Sweden)

    B. Nasre Esfahani

    2000-12-01

    Full Text Available   In this study time-dependent and spherically symmetric solutions of the Einstein field equations in an anisotropic background with a purely radial tension are presented. There exist three classes of solutions,1 An open spacetime with a wormhole at its center. 2 A conical spacetime. 3 A closed spacetime. These inhomogeneous solutions are reduced to FRW spacetimes in matter-dominated era, asymptotically. Therefore, they can be used to describe local inhomogeneities that are not considered in the standard model. For the wormhole solution. it is explicity shown that the considered matter is non-exotic, that is, it does not violate the energy conditions. Also, static solutions are studied. There is only one static solution,a conical spacetime. In this case, the matter satisfies the energy condition critically.

  12. The Curriculum. Conceptual and Practical Tensions

    Directory of Open Access Journals (Sweden)

    Ángel Díaz Barriga

    2003-11-01

    Full Text Available The purpose of this essay is to analyze the formation of two currents in the field of curriculum. These currents, over the last century, were visualized in different ways: one which considers the educational project as linked to a system or an educational institution, a perspective expressed in the various proposals to develop study plans and programs; the other, which links it with concepts like everyday life, curriculum as educational practice and curricular reality, which vindicate what is happening in the educational environment, particularly in the classroom. This paper recognizes a meeting of both currents in the origins of the curriculum field in the early twentieth century; at the same time we analyze its evolution marked by mutual discrediting and ignorance that have generated tensions. It reflects on the need to identify the limitations of each current, but also to recognize their successes.

  13. Shell tension forces propel Dictyostelium slugs forward.

    Science.gov (United States)

    Rieu, Jean-Paul; Delanoë-Ayari, Hélène

    2012-12-01

    The Dictyostelium slug is an excellent model system for studying collective movements, as it is comprised of about 10(5) cells all moving together in the same direction. It still remains unclear how this movement occurs and what the physical mechanisms behind it are. By applying our recently developed 3D traction force microscopy, we propose a simple explanation for slug propulsion. Most of the forces are exerted by the sheath surrounding the slug. This secreted shell is under a rather uniform tension (around 50 mN m(-1)) and will give rise to a tissue under pressure. Finally, we propose that this pressure will naturally push the slug tip forwards if a gradient of shell mechanical properties takes place in the very anterior part of the raised tip.

  14. Biaxial tension on polymer in thermoforming range

    Science.gov (United States)

    Becker, S.; Combeaud, C.; Fournier, F.; Rodriguez, J.; Billon, N.

    2010-06-01

    This paper presents an experimental characterization of mechanical properties of a polyethylene terephtalate (PET) resin classically used in stretch blow moulding process. We have applied on such a material a well established experimental protocol at CEMEF, including new and relevant biaxial tensile tests. The experimental set-up relative to biaxial tension will be presented and described in a first part of the paper. Furthermore, we will focus on the experimental DMTA preliminary tests which are required to estimate the resin sensibility to temperature and strain rate in linear viscoelasticity domain. Finally, we will be interested in the material large strain behaviour: biaxial tensile results are presented and discussed. Finally, such an experimental approach should allow a relevant modelling of polymer physics and mechanics; this point will not be discussed here because of a lack of time.

  15. Biaxial tension on polymer in thermoforming range

    Directory of Open Access Journals (Sweden)

    Billon N.

    2010-06-01

    Full Text Available This paper presents an experimental characterization of mechanical properties of a polyethylene terephtalate (PET resin classically used in stretch blow moulding process. We have applied on such a material a well established experimental protocol at CEMEF, including new and relevant biaxial tensile tests. The experimental set-up relative to biaxial tension will be presented and described in a first part of the paper. Furthermore, we will focus on the experimental DMTA preliminary tests which are required to estimate the resin sensibility to temperature and strain rate in linear viscoelasticity domain. Finally, we will be interested in the material large strain behaviour: biaxial tensile results are presented and discussed. Finally, such an experimental approach should allow a relevant modelling of polymer physics and mechanics; this point will not be discussed here because of a lack of time.

  16. Steady periodic gravity waves with surface tension

    CERN Document Server

    Walsh, Samuel

    2009-01-01

    In this paper we consider two-dimensional, stratified, steady water waves propagating over an impermeable flat bed and with a free surface. The motion is assumed to be driven by capillarity (that is, surface tension) on the surface and a gravitational force acting on the body of the fluid. We prove the existence of global continua of classical solutions that are periodic and traveling. This is accomplished by first constructing a 1-parameter family of laminar flow solutions, $\\mathcal{T}$, then applying bifurcation theory methods to obtain local curves of small amplitude solutions branching from $\\mathcal{T}$ at an eigenvalue of the linearized problem. Each solution curve is then continued globally by means of a degree theoretic theorem in the spirit of Rabinowitz. Finally, we complement the degree theoretic picture by proving an alternate global bifurcation theorem via the analytic continuation method of Dancer.

  17. Shell tension forces propel Dictyostelium slugs forward

    Science.gov (United States)

    Rieu, Jean-Paul; Delanoë-Ayari, Hélène

    2012-12-01

    The Dictyostelium slug is an excellent model system for studying collective movements, as it is comprised of about 105 cells all moving together in the same direction. It still remains unclear how this movement occurs and what the physical mechanisms behind it are. By applying our recently developed 3D traction force microscopy, we propose a simple explanation for slug propulsion. Most of the forces are exerted by the sheath surrounding the slug. This secreted shell is under a rather uniform tension (around 50 mN m-1) and will give rise to a tissue under pressure. Finally, we propose that this pressure will naturally push the slug tip forwards if a gradient of shell mechanical properties takes place in the very anterior part of the raised tip.

  18. Modifying horizon thermodynamics by surface tensions

    CERN Document Server

    Chen, Deyou

    2016-01-01

    The modified first laws of thermodynamics at the black hole horizon and the cosmological horizon of the Schwarzschild de Sitter black hole and the apparent horizon of the Friedmann-Robertson-Walker cosmology are derived by the surface tensions, respectively. The corresponding Smarr relations are obeyed. For the black hole, the cosmological constant is first treated as a fixed constant, and then as a variable associated to the pressure. The law at the apparent horizon takes the same form as that at the cosmological horizon, but is different from that at the black hole horizon. The positive temperatures guarantee the appearance of the worked terms in the modified laws at the cosmological and apparent horizons. While they can disappear at the black hole horizon.

  19. Neurotrophic factors in tension-type headache

    Directory of Open Access Journals (Sweden)

    Renan B. Domingues

    2015-05-01

    Full Text Available Neurotrophic factors (NF are involved in pain regulation and a few studies have suggested that they may play a pathophysiological role in primary headaches. The aim of this study was to investigate NF levels in patients with tension type headache (TTH. We carried out a cross sectional study including 48 TTH patients and 48 age and gender matched controls. Beck Depression and Anxiety Inventories, and Headache Impact Test were recorded. Serum levels of NF were determined by ELISA. There were not significant differences between NF levels between TTH patients and controls. Patients with chronic and episodic TTH had not significant differences in NF levels. The presence of headache at the time of evaluation did not significantly alter the levels of NF. Depression and anxiety scores as well as headache impact did not correlate with NF levels. Our study suggest that the serum levels of NF are not altered in TTH.

  20. Surface tension propulsion of fungal spores.

    Science.gov (United States)

    Noblin, Xavier; Yang, Sylvia; Dumais, Jacques

    2009-09-01

    Most basidiomycete fungi actively eject their spores. The process begins with the condensation of a water droplet at the base of the spore. The fusion of the droplet onto the spore creates a momentum that propels the spore forward. The use of surface tension for spore ejection offers a new paradigm to perform work at small length scales. However, this mechanism of force generation remains poorly understood. To elucidate how fungal spores make effective use of surface tension, we performed a detailed mechanical analysis of the three stages of spore ejection: the transfer of energy from the drop to the spore, the work of fracture required to release the spore from its supporting structure and the kinetic energy of the spore after ejection. High-speed video imaging of spore ejection in Auricularia auricula and Sporobolomyces yeasts revealed that drop coalescence takes place over a short distance ( approximately 5 microm) and energy transfer is completed in less than 4 mus. Based on these observations, we developed an explicit relation for the conversion of surface energy into kinetic energy during the coalescence process. The relation was validated with a simple artificial system and shown to predict the initial spore velocity accurately (predicted velocity: 1.2 m s(-1); observed velocity: 0.8 m s(-1) for A. auricula). Using calibrated microcantilevers, we also demonstrate that the work required to detach the spore from the supporting sterigma represents only a small fraction of the total energy available for spore ejection. Finally, our observations of this unique discharge mechanism reveal a surprising similarity with the mechanics of jumping in animals.