WorldWideScience

Sample records for municipal heat supply

  1. Scenarios for sustainable heat supply and heat savings in municipalities - the case of Helsingør, Denmark

    DEFF Research Database (Denmark)

    Ben Amer-Allam, Sara; Münster, Marie; Petrovic, Stefan

    2017-01-01

    Local climate action is not only a domain of large cities, but also smaller urban areas that increasingly address climate change mitigation in their policy. The Danish municipality of Helsingør can achieve a substantial CO2 emissions reduction by transforming its heat supply and deploying heat...... savings. In this paper, we model the heating system of Helsingør, assess it from a simple socio- and private-economic perspective, develop future scenarios, and conduct an iterative process to derive a cost-optimal mix between district heating, individual heating and heat savings. The results show...... of heating and/or cooling supply for different demand configurations, geographical region and scale....

  2. Optimal supply and demand investments in municipal energy systems

    International Nuclear Information System (INIS)

    Rolfsman, Bjoern

    2004-01-01

    In many municipalities, there are district heating networks, which are quite commonly supplied by combined heat and power plants (CHP). A district heating network contains buildings of different types. In this paper, one such municipal energy system is analysed. In order to provide space heating and domestic hot water, investments could be made on the supply side in power plants, or on the demand side in the buildings, for example in the form of extra wall insulation. The electricity from the CHP plants is supplied to the municipality but can also be sold to the electricity market, and electricity can, of course, also be bought from the market. The variation in price on the spot market over any given day is significant. The need for district heat in the building stock also varies, for example due to climatic conditions. The energy system in the case study is analysed with a mixed integer linear programming model. The model has 3 h time steps in order to reflect diurnal variations, and an entire year is analysed. A case study is presented for the city of Linkoeping in Sweden. On the demand side, the options are: extra wall insulation, extra attic insulation and better types of windows. The building stock is divided into nine categories

  3. Regionalized LCA-based optimization of building energy supply: method and case study for a Swiss municipality.

    Science.gov (United States)

    Saner, Dominik; Vadenbo, Carl; Steubing, Bernhard; Hellweg, Stefanie

    2014-07-01

    This paper presents a regionalized LCA-based multiobjective optimization model of building energy demand and supply for the case of a Swiss municipality for the minimization of greenhouse gas emissions and particulate matter formation. The results show that the environmental improvement potential is very large: in the optimal case, greenhouse gas emissions from energy supply could be reduced by more than 75% and particulate emissions by over 50% in the municipality. This scenario supposes a drastic shift of heat supply systems from a fossil fuel dominated portfolio to a portfolio consisting of mainly heat pump and woodchip incineration systems. In addition to a change in heat supply technologies, roofs, windows and walls would need to be refurbished in more than 65% of the municipality's buildings. The full potential of the environmental impact reductions will hardly be achieved in reality, particularly in the short term, for example, because of financial constraints and social acceptance, which were not taken into account in this study. Nevertheless, the results of the optimization model can help policy makers to identify the most effective measures for improvement at the decision making level, for example, at the building level for refurbishment and selection of heating systems or at the municipal level for designing district heating networks. Therefore, this work represents a starting point for designing effective incentives to reduce the environmental impact of buildings. While the results of the optimization model are specific to the municipality studied, the model could readily be adapted to other regions.

  4. Research of the heat exchanging processes running in the heating and hot water supply loops of the coil heat exchangers

    Directory of Open Access Journals (Sweden)

    Ірина Геннадіївна Шитікова

    2016-11-01

    Full Text Available The fuel-energy complex research has made it possible to disclose a huge power-saving potential in the municipal heat-and-power engineering. Power-and-resource-saving units and systems are becoming extremely urgent because of the power engineering crisis expansion. The self-adjusting heat supply system from the individual heating points with the heat-accumulating units and coil heat exchangers for independent heating and water supply systems has been examined. Coil heat exchangers are used in municipal heating for heat transfer (e.g. geothermal waters for the independent mains of the heating and hot water supply systems. The heat engineering calculation of the heating and accumulating unit with the coil heat exchanger for independent heat supply systems from individual heater was performed and experimental data were received at the experimental industrial unit under the laboratory conditions. The peculiarities of the flows in the intertubular space, their influence on the heat exchange and temperatures of the first and intermediate mains have been shown. It is important to know the processes running inside the apparatus to be able to improve the technical characteristics of the three-loop coil heat exchanger. The task solution will make it possible to save the materials consumption for the three-loop coil heat exchangers in the future

  5. Wind power integration in Aalborg Municipality using compression heat pumps and geothermal absorption heat pumps

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2013-01-01

    -temperature geothermal resources. The analyses have also demonstrated that the municipality will still rely heavily on surrounding areas for electric load balancing assistance. With a departure in a previously elaborated 100% renewable energy scenario, this article investigates how absorption heat pumps (AHP......Aalborg Municipality, Denmark is investigating ways of switching to 100% renewable energy supply over the next 40 years. Analyses so far have demonstrated a potential for such a transition through energy savings, district heating (DH) and the use of locally available biomass, wind power and low......) and compression heat pumps (HP) for the supply of DH impact the integration of wind power. Hourly scenario-analyses made using the EnergyPLAN model reveal a boiler production and electricity excess which is higher with AHPs than with HPs whereas condensing mode power generation is increased by the application...

  6. Strategi for CO2-reduktion i den individuelle varmeforsyning: Strategy for CO2 reduction in the individual heat supply

    OpenAIRE

    Schjerling, Tina Gliese

    2008-01-01

    The project is made in cooperation with Lolland municipality, which has set a series of ambitious goals in relation to reducing the CO2 emissions in the municipality. One of the challenges faced by the municipality in this connection is to achieve a cleaner heat supply. The collective heat supply is almost 100% CO2-neutral, as the district heating plants primarily use CO2-neutral fuel. However, there are a great number of households outside the collective heat supply, which are heated by mean...

  7. 40 CFR 230.50 - Municipal and private water supplies.

    Science.gov (United States)

    2010-07-01

    ... a municipal or private water supply system. (b) Possible loss of values: Discharges can affect the... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Municipal and private water supplies... Potential Effects on Human Use Characteristics § 230.50 Municipal and private water supplies. (a) Municipal...

  8. Heat supply from municipal solid waste incineration plants in Japan: Current situation and future challenges.

    Science.gov (United States)

    Tabata, Tomohiro; Tsai, Peii

    2016-02-01

    The use of waste-to-energy technology as part of a municipal solid waste management strategy could reduce the use of fossil fuels and contribute to prevention of global warming. In this study, we examined current heat and electricity production by incineration plants in Japan for external use. Herein, we discuss specific challenges to the promotion of heat utilisation and future municipal solid waste management strategies. We conducted a questionnaire survey to determine the actual conditions of heat production by incineration plants. From the survey results, information of about 498 incineration plants was extracted. When we investigated the relationship between heat production for external use and population density where incineration plants were located, we found that regions with a population density situation. © The Author(s) 2015.

  9. Master plan study - District heating Sillamaee municipality. Estonia. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The main deficiencies of the district heating system in Sillamae (Estonia) were identified as being inefficiency of the heat and power production plant, which has a very low capacity, lack of means for consumers to control their energy consumption due to the existing constant flow system, pollution from heat and power production based on oil shale, water and heat losses from the network and unclear agreements between the Silmet factory and Sillamae municipality. The available capital for funding is limited. It was investigated where in the system investments would have the greatest effect. A scenario where heat is supplied from individual gas-fired boilers was calculated. A financially viable scenario would be to change from cogeneration of heat and power (CHP) based on oil shale to either individual natural gas supply or peat-fueled heat production. The Sillamae municipality and the Estonian government should agree on a solution for Sillamae. There will be a cash flow problem if the project is implemented. This can be partly solved by introducing a longer loan period. it is expected that there will be no substantial changes in the consumers` heat demand in the `do nothing`scenario, and in other scenarios ca. 520 Tj/p.a. from the Solmet factory, 530 Tj/p.a. from the town and 260 Tj/p.a. as heat losses, totaling 1310 Tj/p.a.. In another scenario - the introduction of natural gas - the town`s heat demand will be 530 Tj/p.a. and there will be no heat losses. More detailed studies of environmental impacts should be undertaken. (ARW)

  10. Master plan study - District heating Sillamaee municipality. Estonia. Final report

    International Nuclear Information System (INIS)

    1997-03-01

    The main deficiencies of the district heating system in Sillamae (Estonia) were identified as being inefficiency of the heat and power production plant, which has a very low capacity, lack of means for consumers to control their energy consumption due to the existing constant flow system, pollution from heat and power production based on oil shale, water and heat losses from the network and unclear agreements between the Silmet factory and Sillamae municipality. The available capital for funding is limited. It was investigated where in the system investments would have the greatest effect. A scenario where heat is supplied from individual gas-fired boilers was calculated. A financially viable scenario would be to change from cogeneration of heat and power (CHP) based on oil shale to either individual natural gas supply or peat-fueled heat production. The Sillamae municipality and the Estonian government should agree on a solution for Sillamae. There will be a cash flow problem if the project is implemented. This can be partly solved by introducing a longer loan period. it is expected that there will be no substantial changes in the consumers' heat demand in the 'do nothing'scenario, and in other scenarios ca. 520 Tj/p.a. from the Solmet factory, 530 Tj/p.a. from the town and 260 Tj/p.a. as heat losses, totaling 1310 Tj/p.a.. In another scenario - the introduction of natural gas - the town's heat demand will be 530 Tj/p.a. and there will be no heat losses. More detailed studies of environmental impacts should be undertaken

  11. Energy supply and urban planning projects: Analysing tensions around district heating provision in a French eco-district

    International Nuclear Information System (INIS)

    Gabillet, Pauline

    2015-01-01

    Through the analysis of energy supply choices, this article explores the way in which energy priorities and their climate-related features are incorporated into urban public policy. These choices must take account of different factors, as is the case with district heating, which is justified as a vehicle of renewable energy while subject to pressure in eco-districts because its techno-economic balances are destabilised by falls in demand. Our study focuses particularly on the city of Metz (France), which has chosen district heating as the primary source for provision for the municipal area and for its first eco-district. We analyse the tensions within these choices, with particular attention to the way in which they are negotiated inside municipal departments and with the local energy operator. This enables us to explore the tensions in defining the scale that governs decisions and the linkages between energy-related and urban priorities. - Highlights: • Analyses of tensions in the choice of energy supplies for eco-districts. •District heating networks can be vehicles of renewable energy. • District heating networks are threatened by drops in energy consumption. • Energy supply issues oppose urban planning and energy policy in municipal departments. • Technical and financial adjustments can be made by the municipality to justify its energy choices

  12. Thermal Efficiency of Cogeneration Units with Multi-Stage Reheating for Russian Municipal Heating Systems

    Directory of Open Access Journals (Sweden)

    Evgeny Lisin

    2016-04-01

    Full Text Available This paper explores the layout of an optimum process for supplying heat to Russian municipal heating systems operating in a market environment. We analyze and compare the standard cogeneration unit design with two-stage reheating of service water coming from controlled extraction locations and layouts that employ three in-line reheaters with heat the supply controlled by a rotary diaphragm and qualitative/quantitative methods (so-called “uncontrolled extraction”. Cogeneration unit designs are benchmarked in terms of their thermal efficiency expressed as a fuel consumption rate. The specific fuel consumption rate on electricity production is viewed as a key parameter of thermal efficiency.

  13. Developing a Procedure for Segmenting Meshed Heat Networks of Heat Supply Systems without Outflows

    Science.gov (United States)

    Tokarev, V. V.

    2018-06-01

    The heat supply systems of cities have, as a rule, a ring structure with the possibility of redistributing the flows. Despite the fact that a ring structure is more reliable than a radial one, the operators of heat networks prefer to use them in normal modes according to the scheme without overflows of the heat carrier between the heat mains. With such a scheme, it is easier to adjust the networks and to detect and locate faults in them. The article proposes a formulation of the heat network segmenting problem. The problem is set in terms of optimization with the heat supply system's excessive hydraulic power used as the optimization criterion. The heat supply system computer model has a hierarchically interconnected multilevel structure. Since iterative calculations are only carried out for the level of trunk heat networks, decomposing the entire system into levels allows the dimensionality of the solved subproblems to be reduced by an order of magnitude. An attempt to solve the problem by fully enumerating possible segmentation versions does not seem to be feasible for systems of really existing sizes. The article suggests a procedure for searching rational segmentation of heat supply networks with limiting the search to versions of dividing the system into segments near the flow convergence nodes with subsequent refining of the solution. The refinement is performed in two stages according to the total excess hydraulic power criterion. At the first stage, the loads are redistributed among the sources. After that, the heat networks are divided into independent fragments, and the possibility of increasing the excess hydraulic power in the obtained fragments is checked by shifting the division places inside a fragment. The proposed procedure has been approbated taking as an example a municipal heat supply system involving six heat mains fed from a common source, 24 loops within the feeding mains plane, and more than 5000 consumers. Application of the proposed

  14. District heating system of Belgrade supplied from the co-generation plant 'Obrenovac' (Yugoslavia)

    International Nuclear Information System (INIS)

    Tomic, P.; Dobric, Z.; Studovic, M.

    2000-01-01

    The paper presents most relevant technical and economic features of the Project called 'System for supplying Belgrade with heat' (SDGB) from the thermal power plant 'Obrenovac', based on domestic coal and reconstruction of condensing power plant for combined generation of electricity and heat for the needs of municipal energy consumption. The system is designed for transport thermal energy, with capacity of 730 MJ/s from the Thermal Power Plant 'Nikola Tesla' / A to the existing heat plant 'Novi Beograd' based on the natural gas. The paper also gives the comparison of most important technical and economic features of 'SDGB' Project with the similar Project of District Heating System for supplying Prague with the thermal energy from Thermal Power Plant Melnik. (Author)

  15. Heat supply to low energy dwellings in district heating areas. Analyses of CO{sub 2} emissions and electricity supply security; Varmeforsyning til lavenergiboliger i omraader med fjernvarmekonsesjon. Analyser av CO{sub 2}-utslipp og forsyningssikkerhet for elektrisitet

    Energy Technology Data Exchange (ETDEWEB)

    Thyholt, Marit

    2006-07-01

    Building low energy dwellings in large development projects is a new situation in Norway. The municipalities have to a little extent analyzed the consequences of this new housing standard with respect to the energy supply to such areas, and how this standard may change the plans for new or extended district heat production. In the provision about the mandatory connection to district heating plants, and the appendant provision related to a heating system that can utilize district heat, the district heat supply and the heat demand are not seen in connection. The objective of this dissertation is to provide the municipalities with a basis for decision making in the processing of applications concerning dispensation from the mandatory connection or the heating system requirement for dwellings with low heat demand. This basis for decision making is based on the national aim of reducing carbon dioxide (CO{sub 2}) emissions and of improving the electricity supply security. This summary provides an abstract from the discussion of the legislation as an incentive or barrier for building low energy dwellings. An abstract from a survey among construction firms concerning the motivation for building low energy dwellings is also included. In addition, the summary provides a comprehensive abstract of the results from the CO{sub 2} emission calculations, and the basis for these calculations. Introductorily a brief background of the national focus on energy savings and increased use of hydronic heating, including district heat, is given.

  16. Cogeneration and District Heating. Best Practices for Municipalities

    International Nuclear Information System (INIS)

    Nuorkivi, A.; Constantinescu, T.

    2005-01-01

    District heating (DH) and cogeneration of heat power (CHP) are well known technologies in the energy business and are often included in municipal policies as well. Some of the major benefits of DH and CHP are less known and the barriers faced by further development of DH and CHP are substantial. The main barriers are institutional. Municipalities can play a powerful role in facilitating local DH and CHP development in order to achieve the economic and environmental benefits of DH and CHP. This report is produced to assist municipalities in promoting efficient and environmental beneficial DH and CHP. The focus of the report is on the economies in transition, where the institutional barriers are acute. The report addresses the issues of organisational framework, price regulation and financing, energy demand, rehabilitation of DH systems and benchmarking of DH and CHP. The municipality may influence the DH development by a number of means. The most important means, discussed in the various chapters of the report, are: (1) City planning impacts on the heat load density. A high density is an important factor for the economics of DH and city planning may promote DH in areas with high density and individual heating modes in the areas with low density; (2) Managing the building stock owned by the municipality to join the DH system and paying for the heating services; (3) Setting strategic goals for the District Heating Enterprise (DHE), which they usually own, regarding the quality and the costs of heating. The DHE shall be given sufficient resources to work towards such goals; (4) Providing guarantees for financing DH rehabilitation and development. The DHE may not have access to commercial credits without municipal guarantees; and, (5) Supporting the DHE management by giving operational independence, supervising the management performance regularly and encouraging the co-operation with other DHEs and equipment manufacturers. Examples provided in the report of

  17. Projecting demand and supply of forest biomass for heating in Norway

    International Nuclear Information System (INIS)

    Tromborg, Erik; Havskjold, Monica; Lislebo, Ole; Rorstad, Per Kristian

    2011-01-01

    This paper assesses the increase in demand and supply for forest biomass for heating in Norway in 2020. By then there is a political aim to double the national production of bioenergy from the level in 2008. The competitiveness of woody biomass in central and district heating is analyzed in a model selecting the least-cost heating technology and scale in municipalities given a set of constraints and under different fuels price scenarios. The supply of forest biomass from roundwood is estimated based on data of forest inventories combined with elasticities regarding price and standing volumes. The supply of biomass from harvesting residues is estimated in an engineering approach based on data from the national forest inventories and roundwood harvest. The results show how the production of bioenergy is affected by changes in energy prices and support schemes for bioenergy. One conclusion from the analyses is that the government target of 14 TWh more bioenergy by 2020 is not likely to be met by current technologies and policy incentives. The contribution of the analysis is the detailed presentation of the heat market potentials and technology choices combined with supply functions for both roundwood and harvesting residues. - Highlights: → This paper accesses the demand and supply for forest biomass for heating in Norway in 2020. → Market share for wood in central and new district heating is analyzed in a cost-minimizing model. → The supply of forest biomass includes wood chips from import, roundwood and harvesting residues. → The production of bioenergy is affected by changes in energy prices and support schemes. → The government target for bioenergy is not met by current technologies and policy incentives.

  18. Geothermal heat-pump systems of heat supply

    International Nuclear Information System (INIS)

    Vasil'ev, G.P.

    2004-01-01

    The data on the multilayer operation of the objects, located in the climatic conditions of the central area of Russia and equipped with the geothermal heat-pumping systems of the heat supply are presented. The results of the analytical studies on evaluating the geothermal heat-pumping systems of the heat supply integration efficiency into the structure of the energy supply system, prevailing in the country, are presented [ru

  19. Application of SAW method for multiple-criteria comparative analysis of the reliability of heat supply organizations

    Science.gov (United States)

    Akhmetova, I. G.; Chichirova, N. D.

    2016-12-01

    Heat supply is the most energy-consuming sector of the economy. Approximately 30% of all used primary fuel-and-energy resources is spent on municipal heat-supply needs. One of the key indicators of activity of heat-supply organizations is the reliability of an energy facility. The reliability index of a heat supply organization is of interest to potential investors for assessing risks when investing in projects. The reliability indices established by the federal legislation are actually reduced to a single numerical factor, which depends on the number of heat-supply outages in connection with disturbances in operation of heat networks and the volume of their resource recovery in the calculation year. This factor is rather subjective and may change in a wide range during several years. A technique is proposed for evaluating the reliability of heat-supply organizations with the use of the simple additive weighting (SAW) method. The technique for integrated-index determination satisfies the following conditions: the reliability level of the evaluated heat-supply system is represented maximum fully and objectively; the information used for the reliability-index evaluation is easily available (is located on the Internet in accordance with demands of data-disclosure standards). For reliability estimation of heat-supply organizations, the following indicators were selected: the wear of equipment of thermal energy sources, the wear of heat networks, the number of outages of supply of thermal energy (heat carrier due to technological disturbances on heat networks per 1 km of heat networks), the number of outages of supply of thermal energy (heat carrier due to technologic disturbances on thermal energy sources per 1 Gcal/h of installed power), the share of expenditures in the cost of thermal energy aimed at recovery of the resource (renewal of fixed assets), coefficient of renewal of fixed assets, and a coefficient of fixed asset retirement. A versatile program is developed

  20. Discussion on Construction Technology of Prestressed Reinforced Concrete Pipeline of Municipal Water Supply and Drainage

    Science.gov (United States)

    Li, Chunyan

    2017-11-01

    Prestressed reinforced concrete pipe has the advantages of good bending resistance, good anti-corrosion, anti-seepage, low price and so on. It is very common in municipal water supply and drainage engineering. This paper mainly explore the analyze the construction technology of the prestressed reinforced concrete pipe in municipal water supply and drainage engineering.

  1. How Danish communal heat planning empowers municipalities and benefits individual consumers

    DEFF Research Database (Denmark)

    Chittum, Anna; Østergaard, Poul Alberg

    2014-01-01

    Danish municipal heat planning empowers municipalities to implement locally appropriate energy solutions that are the best fit for the locality as a whole and the individual consumers served. Supportive policies and actions at the national and local levels have encouraged heat planning that confe...... locations, the practical aspects of power sharing, socio-economic cost–benefit analyses, and communal decision-making may inform approaches to local heat planning around the world....

  2. Remediation System Evaluation, Savage Municipal Water Supply Superfund Site (PDF)

    Science.gov (United States)

    The Savage Municipal Water Supply Superfund Site, located on the western edge of Milford, New Hampshire, consists of a source area and an extended plume that is approximately 6,000 feet long and 2,500 feet wide.

  3. An Exploration of Supply Chain Management Practices in the Central District Municipality

    Science.gov (United States)

    Ambe, I. M.

    2009-01-01

    The main objective of the paper is to explore supply chain management practices in the Central District Municipality, North West province of South Africa, using the grounded theory methodology. Supply chain management was introduced in the South African public sector to alleviate deficiencies related to governance, interpretation and…

  4. A renewable energy scenario for Aalborg Municipality based on low-temperature geothermal heat, wind power and biomass

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg; Mathiesen, Brian Vad; Möller, Bernd

    2010-01-01

    Aalborg Municipality, Denmark, wishes to investigate the possibilities of becoming independent of fossil fuels. This article describes a scenario for supplying Aalborg Municipality’s energy needs through a combination of low-temperature geothermal heat, wind power and biomass. Of particular focus...... in the scenario is how low-temperature geothermal heat may be utilised in district heating (DH) systems. The analyses show that it is possible to cover Aalborg Municipality’s energy needs through the use of locally available sources in combination with significant electricity savings, heat savings, reductions...... in industrial fuel use and savings and fuel-substitutions in the transport sector. With biomass resources being finite, the two marginal energy resources in Aalborg are geothermal heat and wind power. If geothermal heat is utilised more, wind power may be limited and vice versa. The system still relies...

  5. How Danish communal heat planning empowers municipalities and benefits individual consumers

    International Nuclear Information System (INIS)

    Chittum, Anna; Østergaard, Poul Alberg

    2014-01-01

    Danish municipal heat planning empowers municipalities to implement locally appropriate energy solutions that are the best fit for the locality as a whole and the individual consumers served. Supportive policies and actions at the national and local levels have encouraged heat planning that confers significant autonomy to local governments. By examining how power is distributed and shared by different levels of governments in the planning process, this paper investigates how comprehensive energy planning in Denmark has supported the development of highly cost-effective district heating systems. Lessons from the Danish approach to heat planning are considered for their relevance to the United States, where significant technical district heating potential exists, yet remains well outside the typical energy policy discussions. While the specific Danish political context may not be transferable to other locations, the practical aspects of power sharing, socio-economic cost–benefit analyses, and communal decision-making may inform approaches to local heat planning around the world. - Highlights: • Danish district heating has cost-effectively reduced the country's emissions. • Danish heat planning has been critical to the district heating sector's success. • Danish heat planning confers substantial power to municipalities. • Empowering cities offers significant benefits to cities and consumers. • Danish planning practices can be implemented today in the U.S. and other locations

  6. Distribution of aquifers, liquid-waste impoundments, and municipal water-supply sources, Massachusetts

    Science.gov (United States)

    Delaney, David F.; Maevsky, Anthony

    1980-01-01

    Impoundments of liquid waste are potential sources of ground-water contamination in Massachusetts. The map report, at a scale of 1 inch equals 4 miles, shows the idstribution of aquifers and the locations of municipal water-supply sources and known liquid-waste impoundments. Ground water, an important source of municipal water supply, is produced from shallow sand and gravel aquifers that are generally unconfined, less than 200 feet thick, and yield less than 2,000 gallons per minute to individual wells. These aquifers commonly occupy lowlands and stream valleys and are most extensive in eastern Massachusetts. Surface impoundments of liquid waste are commonly located over these aquifers. These impoundments may leak and allow waste to infiltrate underlying aquifers and alter their water quality. (USGS)

  7. Municipal water-based heat pump heating and/or cooling systems: Findings and recommendations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bloomquist, R.G. [Washington, State Univ., Pullman, WA (United States); Wegman, S. [South Dakota Utilities Commission (United States)

    1998-04-01

    The purpose of the present work was to determine if existing heat pump systems based on municipal water systems meet existing water quality standards, to analyze water that has passed through a heat pump or heat exchanger to determine if corrosion products can be detected, to determine residual chlorine levels in municipal waters on the inlet as well as the outlet side of such installations, to analyses for bacterial contaminants and/or regrowth due to the presence of a heat pump or heat exchanger, to develop and suggest criteria for system design and construction, to provide recommendations and specifications for material and fluid selection, and to develop model rules and regulations for the installation, operation, and monitoring of new and existing systems. In addition, the Washington State University (WSU) has evaluated availability of computer models that would allow for water system mapping, water quality modeling and system operation.

  8. Process heat supply requirements on HTGRs

    International Nuclear Information System (INIS)

    Schad, M.K.

    1989-01-01

    Since it has been claimed that the MHTGR is competitive with coal in producing electricity, the MHTGR must be competitive in producing process heat. There is a huge process heat market and there are quite a number of processes where the industrial MHTGR = HTRI could supply the necessary process heat and energy. However, to enhance its introduction on the market and to conquer a reasonable share of the market, the HTRI should fulfill the following major requirements: Unlimited constant and flexible heat supply, no secondary heat transport system at higher temperatures and low radioactive contamination level of the primary helium. Unlimited constant and flexible heat supply could be achieved with smaller HTRIs having heat generation capacities below 100 MW-th. The process heat generated by smaller HTRIs need not be more expensive since the installed necessary heat supply redundancy is smaller and the excess power density lower. The process heat at elevated temperatures generated by a HTRI with a secondary heat transfer system is much more expensive due to the additional investment and operating cost as well as the reduced helium temperature span available. For some processes, the HTRI is not able to cover the total process heat requirement while other processes can consume only part of the heat offered. These limitations could be reduced by using higher core outlet and inlet temperatures or both. Due to the considerably lower heat transfer rates and the resulting larger heat transfer areas in process plants, the diffusion of nuclear activity at elevated temperatures may increase so that a more efficient helium cleaning system may be required. (author). 5 figs, 3 tabs

  9. Upscaling a district heating system based on biogas cogeneration and heat pumps

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; de Wit, Jan B.

    2015-01-01

    The energy supply of the Meppel district Nieuwveense landen is based on biogas cogeneration, district heating, and ground source heat pumps. A centrally located combined heat and power engine (CHP) converts biogas from the municipal wastewater treatment facility into electricity for heat pumps and

  10. Decentralized Heat Supply – Alternative to Centralized One

    OpenAIRE

    V. I. Nazarov; L. A. Tarasevich; А. L. Burov

    2012-01-01

    The paper presents a concrete example that shows comparative characteristics of decentralized and centralized heat supply. It has been shown in the paper that selection of this or that variant of heat supply significantly depends on losses in heat supply networks.

  11. Prevalence of Virulent Escherichia coli Belonging B1 Phylogroup in Municipal Water Supply in Dhaka, Bangladesh

    DEFF Research Database (Denmark)

    Ferdous, Jannataul; Rashid, Ridwan Bin; Tulsiani, Suhella

    isolated from drinking water in Arichpur, a low income area of Dhaka, Bangladesh. The distribution of the phylogroups and virulence genes were investigated in 200 isolates among them 110 isolates were from municipal water supply system and 90 were from household drinking water. Gene profile of virulence.......001. Therefore, it can be inferred municipal water supply was a greater contributor of pathogenic E. coli from the B1 phylogroup. Usually commensals fall in the Phylogroups A and B1. The presence of greater number of virulent B1 phylogroup isolates originating from municipal water supply indicates......Escherichia coli is a commensal organism of the digestive tracts of many vertebrates, including humans. Contamination of drinking water with pathogenic E. coli is a serious public health concern. This study focused on the distribution of phylogenetic groups and virulence gene profile of E. coli...

  12. Ringkøbing-Skjern Energy Atlas for municipal energy planning

    DEFF Research Database (Denmark)

    Petrovic, Stefan; Karlsson, Kenneth Bernard

    2015-01-01

    Ringkøbing-Skjern is Denmark's largest municipality, located in the west part of Central Denmark Region. Its medium-term goal is to achieve 100 % self-sufficiency in renewable energy supply by 2020. To achieve this ambitious goal, future courses of action have been outlined in the municipality......'s energy strategy "Energy2020" and divided into five groups: increasing production from wind, bioenergy and other renewable energy sources, reducing heat demand in buildings and converting transportation sector to renewable energy. The analysis of technical, economic and environmental impacts...... of such a variety of technologies on the municipality's energy system requires highly detailed decision support system. For that purpose, GIS-based energy atlas has been developed for Ringkøbing-Skjern municipality. The data about energy supply and demand, transmission and distribution infrastructure, energy...

  13. Decentralized Heat Supply – Alternative to Centralized One

    Directory of Open Access Journals (Sweden)

    V. I. Nazarov

    2012-01-01

    Full Text Available The paper presents a concrete example that shows comparative characteristics of decentralized and centralized heat supply. It has been shown in the paper that selection of this or that variant of heat supply significantly depends on losses in heat supply networks.

  14. Municipal Development of Anaerobic Digestion/ Combined Heat and Power in Massachusetts

    Science.gov (United States)

    Pike, Brenda

    With a commercial food waste ban going into effect in Massachusetts in October 2014, businesses, institutions, and municipalities are considering alternatives to landfills and incinerators for organic waste. Anaerobic digestion is one such alternative. Similar to composting, but in an environment devoid of oxygen, anaerobic digestion produces byproducts such as methane (which can be burned for heat or electricity) and liquid or solid digestate (which can be used as fertilizer, cattle bedding, and more). Thus, disposal of food waste and other organic materials can become a source of revenue rather than just an expense. Municipalities interested in developing anaerobic digestion/combined heat and power (AD/CHP) facilities have the benefit of desirable options for sites, such as landfill gas facilities and wastewater treatment plants, and potential feedstocks in source-separated residential or municipal food waste or wastewater. This thesis examines the opportunities and challenges for municipal development of AD/CHP facilities in Massachusetts.

  15. Optimization of heat supply systems employing nuclear power plants

    International Nuclear Information System (INIS)

    Urbanek, J.

    1988-01-01

    Decision making on the further development of heat supply systems requires optimization of the parameters. In particular, meeting the demands of peak load ranges is of importance. The heat supply coefficient α and the annual utilization of peak load equipment τ FS have been chosen as the characteristic quantities to describe them. The heat price at the consumer, C V , offers as the optimization criterion. The transport distance, temperature spread of the heating water, and different curves of annual variation of heat consumption on heat supply coefficient and heat price at the consumer. A comparison between heat supply by nuclear power plants and nuclear heating stations verifies the advantage of combined heat and power generation even with longer heat transport distances as compared with local heat supply by nuclear district heating stations based on the criterion of minimum employment of peak load boilers. (author)

  16. High resolution heat atlases for demand and supply mapping

    Directory of Open Access Journals (Sweden)

    Bernd Möller

    2014-02-01

    Full Text Available Significant reductions of heat demand, low-carbon and renewable energy sources, and district heating are key elements in 100% renewable energy systems. Appraisal of district heating along with energy efficient buildings and individual heat supply requires a geographical representation of heat demand, energy efficiency and energy supply. The present paper describes a Heat Atlas built around a spatial database using geographical information systems (GIS. The present atlas allows for per-building calculations of potentials and costs of energy savings, connectivity to existing district heat, and current heat supply and demand. For the entire building mass a conclusive link is established between the built environment and its heat supply. The expansion of district heating; the interconnection of distributed district heating systems; or the question whether to invest in ultra-efficient buildings with individual supply, or in collective heating using renewable energy for heating the current building stock, can be based on improved data.

  17. Local energy supply under national and European law. With special regard to municipal policy opportunities

    International Nuclear Information System (INIS)

    Britz, G.

    1994-01-01

    Conceivably, the erection of a single European energy market for electricity and natural gas as specified in the EC draft guidelines may change the conditions of local energy supply. This thesis therefore investigates which instruments are at the disposal of municipal governments for the realization of energy-political concepts of their own: Rights of way and granting of franchises, establishment of and transfer of tasks to municipal utilities, common carvier duties, and free choice of suppliers by distributors. The handling of franchise payments and treatment of municipal interconnected networks are of considerable importance for the financial situation of communities. The first section deals with the legal issues of local energy supply with regard to national law. The second part deals with the same questions with regard to community law. Furthermore it is considered what would be the consequences of the realization of the two guidelines concerning the single energy market. In the final section the results are compared and the significance of community law for local energy supply is assessed. (orig./HP) [de

  18. Optimum design of a nuclear heat supply

    International Nuclear Information System (INIS)

    Borel, J.P.

    1984-01-01

    This paper presents an economic analysis for the optimum design of a nuclear heat supply to a given district-heating network. First, a general description of the system is given, which includes a nuclear power plant, a heating power plant and a district-heating network. The heating power plant is fed with steam from the nuclear power plant. It is assumed that the heating network is already in operation and that the nuclear power plant was previously designed to supply electricity. Second, a technical definition of the heat production and transportation installations is given. The optimal power of these installations is examined. The main result is a relationship between the network capacity and the level of the nuclear heat supply as a substitute for oil under the best economic conditions. The analysis also presents information for choosing the best operating mode. Finally, the heating power plant is studied in more detail from the energy, technical and economic aspects. (author)

  19. Method and means for heating buildings in a district heating system with waste heat from a thermal power plant

    International Nuclear Information System (INIS)

    Margen, P.H.E.

    1975-01-01

    The waste heat from a thermal power plant is transported through a municipal heating network to a plurality of buildings to be heated. The quantity of heat thus supplied to the buildings is higher than that required for the heating of the buildings. The excess heat is released from the buildings to the atmosphere in the form of hot air

  20. The impact of municipal waste combustion in small heat sources

    Science.gov (United States)

    Vantúch, Martin; Kaduchová, Katarína; Lenhard, Richard

    2016-06-01

    At present there is a tendency to make greater use for heating houses for burning solid fuel, such as pieces of wood, coal, coke, local sources of heat to burn natural gas. This tendency is given both the high price of natural gas as well as the availability of cheaper solid fuel. In many cases, in the context saving heating costs, respectively in the context of the disposal of waste is co-incinerated with municipal solid fuels and wastes of different composition. This co entails increased production emissions such as CO (carbon monoxide), NOx (nitrogen oxides), particulate matter (particulate matter), PM10, HCl (hydrogen chloride), PCDD/F (polychlorinated dibenzodioxins and dibenzofurans), PCBs (polychlorinated biphenyls) and others. The experiment was focused on the emission factors from the combustion of fossil fuels in combination with municipal waste in conventional boilers designed to burn solid fuel.

  1. Hybrid district heating system with heat supply from nuclear source

    International Nuclear Information System (INIS)

    Havelka, Z.; Petrovsky, I.

    1987-01-01

    Several designs are described of heat supply from large remote power sources (e.g., WWER-1000 nuclear power plants with a 1000 MW turbine) to localities where mainly steam distribution networks have been built but only some or none networks for hot water distribution. The benefits of the designs stem from the fact that they do not require the conversion of the local steam distribution system to a hot water system. They are based on heat supply from the nuclear power plant to the consumer area in hot water of a temperature of 150 degC to 200 degC. Part of the hot water heat will be used for the production of low-pressure steam which will be compressed using heat pumps (steam compressors) to achieve the desired steam distribution network specifications. Water of lower temperature can be used in the hot water network. The hot water feeder forms an automatic pressure safety barrier in heat supply of heating or technological steam from a nuclear installation. (Z.M.). 5 figs., 9 refs

  2. High resolution heat atlases for demand and supply mapping

    DEFF Research Database (Denmark)

    Möller, Bernd; Nielsen, Steffen

    2014-01-01

    Significant reductions of heat demand, low-carbon and renewable energy sources, and district heating are key elements in 100% renewable energy systems. Appraisal of district heating along with energy efficient buildings and individual heat supply requires a geographical representation of heat...... demand, energy efficiency and energy supply. The present paper describes a Heat Atlas built around a spatial database using geographical information systems (GIS). The present atlas allows for per-building calculations of potentials and costs of energy savings, connectivity to existing district heat......, and current heat supply and demand. For the entire building mass a conclusive link is established between the built environment and its heat supply. The expansion of district heating; the interconnection of distributed district heating systems; or the question whether to invest in ultra-efficient buildings...

  3. Supply of Prague with heat from a nuclear heat source

    International Nuclear Information System (INIS)

    Poul, F.

    1976-01-01

    The proposals are discussed of supplying Prague, the Czechoslovak Capital, with nuclear reactor-generated heat energy. The proposals meet the requirements of the general urban plan of development. The first nuclear heating plant is to be sited in the Kojetice locality, in the northern Prague suburb. It will be commissioned by 1984 and 1985. It is estimated that the maximum heat output in form of hot water will be 821 MW. By 1995 the construction of the second nuclear heating plant should be started southeast or east of Prague. The connection of these two nuclear plants to the hot water mains together with other conventional heating plants will secure the heat supply for Prague and its new housing estates and industrial works. (Oy)

  4. Small-scale hybrid plant integrated with municipal energy supply system

    International Nuclear Information System (INIS)

    Bakken, B.H.; Fossum, M.; Belsnes, M.M.

    2001-01-01

    This paper describes a research program started in 2001 to optimize environmental impact and cost of a small-scale hybrid plant based on candidate resources, transportation technologies and conversion efficiency, including integration with existing energy distribution systems. Special attention is given to a novel hybrid energy concept fuelled by municipal solid waste. The commercial interest for the model is expected to be more pronounced in remote communities and villages, including communities subject to growing prosperity. To enable optimization of complex energy distribution systems with multiple energy sources and carriers a flexible and robust methodology must be developed. This will enable energy companies and consultants to carry out comprehensive feasibility studies prior to investment, including technological, economic and environmental aspects. Governmental and municipal bodies will be able to pursue scenario studies involving energy systems and their impact on the environment, and measure the consequences of possible regulation regimes on environmental questions. This paper describes the hybrid concept for conversion of municipal solid waste in terms of energy supply, as well as the methodology for optimizing such integrated energy systems. (author)

  5. DEVELOPMENT OF TECHNICAL DECISIONS FOR HEAT SUPPLY WITH TUBULAR GAS HEATERS

    Directory of Open Access Journals (Sweden)

    IRODOV V. F.

    2017-05-01

    Full Text Available Annotation. Problems formulation. The problem that is solved is the development of autonomous heat supply systems that reduce the capital costs of construction and increase the efficiency of the use of energy resources. One of the ways to solve this problem is the use of tubular gas heaters. For this, it is necessary to develop new technical solutions for heat supply with tubular gas heaters, as well as scientific and methodological support for the development, construction and operation of heat supply systems with tubular gas heaters. Analysis of recent research. Preliminary studies of infrared tubular gas heaters are considered, which were used to heat industrial enterprises with sufficiently high premises. The task was to extend the principles of heat supply by means of tubular heaters for heating air, water and heating medium in relatively low rooms. Goal and tasks. To lay out the development of technical solutions for heat supply with tubular gas heaters, which increase the efficiency and reliability of heat supply systems and extend the use of tubular gas heaters in heat supply. Results. Technical solutions for heat supply with tubular gas heaters have made it possible to extend their applications for heating air, water and heating medium in relatively low rooms. Scientific novelty. New technical solutions for heat supply with tubular gas heaters increase the efficiency of using fuel and energy resources at low capital costs. Practical significance. Technical solutions for heat supply using tubular heaters have the potential for wide application in the heat supply of industrial, public and residential facilities. Conclusions. For two decades, new technical solutions for heat supply with tubular gas heaters have been developed, which increase the efficiency and reliability of heat supply systems and can be widely used for autonomous heating.

  6. Prospects for development of heat supply systems in high-rise districts

    Science.gov (United States)

    Zhila, Viktor; Solovyeva, Elena

    2018-03-01

    The article analyzes the main advantages and disadvantages of centralized and decentralized heat supply systems in high-rise districts. The main schemes of centralized heat supply systems are considered. They include centralized heat supply from boiler houses, centralized heat supply from autonomous heat sources, heat supply from roof boiler houses and door-to-door heating supply. For each of these variant, the gas distribution systems are considered and analyzed. These systems vary depending on the heat source location. For each of these systems, technical and economic indicators are taken into account, the analysis of which allows choosing the best option for districts where high-rise buildings predominate.

  7. ON REASONABLE ESTIMATE OF ENERGY PERFORMANCE OF THE RESIDENTIAL BUILDINGS SUSTENANCE WITH CENTRALIZED HEAT-SUPPLY SYSTEM

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2016-01-01

    the period from 2006 to 2013, by virtue of the heat-supply schemes optimization and modernizing the heating systems using valuable (200–300 $US per 1 m though hugely effective preliminary coated pipes, the economy reached 2,7 MIO tons of fuel equivalent. Heat-energy general losses in municipal services of Belarus in March 2014 amounted up 17 %, whilst in 2001 they were at the level of 26 % and in 1990 – more than 30 %. With a glance to multi-staging and multifactorial nature (electricity, heat and water supply of the residential sector energy saving, the reasonable estimate of the residential buildings sustenance energy efficiency should be performed in tons of fuel equivalent in a unit of time.

  8. Future heat supply of our cities. Heating by waste heat

    Energy Technology Data Exchange (ETDEWEB)

    Brachetti, H E [Stadtwerke Hannover A.G. (Germany, F.R.); Technische Univ. Hannover (Germany, F.R.))

    1976-08-01

    The energy-price crisis resulted in structural changes of the complete energy supply and reactivated the question of energy management with respect to the optimum solution of meeting the energy requirements for space heating. Condensation power plants are increasingly replaced by thermal stations, the waste heat of which is used as so-called district heat. Thermal power stations must be situated close to urban areas. The problem of emission of harmful materials can partly be overcome by high-level emission. The main subject of the article, however, is the problem of conducting and distributing the heat. The building costs of heat pipeline systems and the requirements to be met by heat pipelines such as strength, heat insulation and protection against humidity and ground water are investigated.

  9. Optimization of Temperature Schedule Parameters on Heat Supply in Power-and-Heat Supply Systems

    Directory of Open Access Journals (Sweden)

    V. A. Sednin

    2009-01-01

    Full Text Available The paper considers problems concerning optimization of a temperature schedule in the district heating systems with steam-turbine thermal power stations having average initial steam parameters. It has been shown in the paper that upkeeping of an optimum network water temperature permits to increase an energy efficiency of heat supply due to additional systematic saving of fuel. 

  10. Climate change impacts on municipal, mining, and agricultural water supplies in Chile

    Science.gov (United States)

    Daniel G. Neary; Pablo Garcia-Chevesich

    2008-01-01

    Agricultural and municipal water supply interests in Chile rely heavily on streams which flow from the Andes Mountains. The highly productive Copiapo agricultural region, on the southern edge of the Atacama Desert, is a major supplier of fruit and other crops for the Northern American market during winter. This region relies entirely on snow and icemelt streams to...

  11. Prospects of heat supply from Temelin nuclear power plant

    International Nuclear Information System (INIS)

    Kuba, V.

    1987-01-01

    The possibilities are discussed of using the Temelin nuclear power plant for heat supply to a number of localities in the South Bohemian Region, to a distance of up to 34 km. Direct supply of steam and of 150/70 degC or 180/65 degC hot water is envisaged. An alternative solution has also been proposed allowing to supply steam and hot water simultaneously from 180 degC hot water with quantitative regulation. The hot water is made to expand at a pressure of 0.3 to 0.5 MPa and the low-pressure steam is compressed to a pressure of 0.9 to 1.3 MPa. This steam will be supplied to the existing heating system. The possibility was also studied of supplying Prague with heat and 180/65 degC hot water of a thermal output of up to 1,700 MW using a two-pipe heat supply line of 105 to 125 km in length. (B.S.). 2 figs

  12. A Danish Heat Atlas for Supply Strategies and Demand Side Management

    DEFF Research Database (Denmark)

    Möller, Bernd

    The expansion of district heating, the assessment of the impact of heat supply strategies, as well as the analysis of significant heat demand savings require sound decision support at high detail. Data is needed to continuously quantify potentials and costs of measures in the end-use and supply...... heat demand and possible savings. The location of each building relative to heat supply technologies is mapped and used for the assessment of supply strategies by potentials, costs and environmental impact. Both elements can furthermore be used to balance investments in supply with investments...

  13. Mathematical model for calculation of the heat-hydraulic modes of heating points of heat-supplying systems

    Science.gov (United States)

    Shalaginova, Z. I.

    2016-03-01

    The mathematical model and calculation method of the thermal-hydraulic modes of heat points, based on the theory of hydraulic circuits, being developed at the Melentiev Energy Systems Institute are presented. The redundant circuit of the heat point was developed, in which all possible connecting circuits (CC) of the heat engineering equipment and the places of possible installation of control valve were inserted. It allows simulating the operating modes both at central heat points (CHP) and individual heat points (IHP). The configuration of the desired circuit is carried out automatically by removing the unnecessary links. The following circuits connecting the heating systems (HS) are considered: the dependent circuit (direct and through mixing elevator) and independent one (through the heater). The following connecting circuits of the load of hot water supply (HWS) were considered: open CC (direct water pumping from pipelines of heat networks) and a closed CC with connecting the HWS heaters on single-level (serial and parallel) and two-level (sequential and combined) circuits. The following connecting circuits of the ventilation systems (VS) were also considered: dependent circuit and independent one through a common heat exchanger with HS load. In the heat points, water temperature regulators for the hot water supply and ventilation and flow regulators for the heating system, as well as to the inlet as a whole, are possible. According to the accepted decomposition, the model of the heat point is an integral part of the overall heat-hydraulic model of the heat-supplying system having intermediate control stages (CHP and IHP), which allows to consider the operating modes of the heat networks of different levels connected with each other through CHP as well as connected through IHP of consumers with various connecting circuits of local systems of heat consumption: heating, ventilation and hot water supply. The model is implemented in the Angara data

  14. Sustainable heat supply. Status report; Nachhaltige Waermeversorgung. Sachstandsbericht

    Energy Technology Data Exchange (ETDEWEB)

    Strohschein, Jan; Erdmenger, Christoph; Albert, Reihard (and others)

    2007-03-15

    The Federal Environmental Office views sustainable energy supply - of which the heat market is a decisive element - mostly under the aspect of climate protection and emission reduction of climate-relevant gases. If the heat market is to make a contribution here, the heat supply system must be reorganized. This publication of the Federal Environmental Office indicates fields of action in the heat market. The focus is on climate-friendly heat production, e.g. renewable energy sources, cogeneration systems, and higher energy efficiency. The full report can be downloaded from http://www.umweltbundesamt.de/klimaschutz/. (orig./AKB)

  15. A Policy study on stabilization of heating oil supply and demand

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bok Jae [Korea Energy Economics Institute, Euiwang (Korea)

    1999-03-01

    As a principal heating fuel for household and commercial sector, and a heat source fuel for industry, the heating oil shows its great demand intensively during a specific period (wintertime) due to its characteristics. It represents that the fluctuation of heating oil demand throughout the year is very extreme. Therefore, the stable supply of heating oil has been rising as an important task. It is desirable to develop and supply a new type of heating oil compounded of kerosene and gasoline with appropriate ratio for short- and mid-term to have a stable supply and demand of heating oil. For long-term prospect, it is desirable to supply petroleum products mixing gasoline and B-C oil as heating oil when it is equipped with combustion technology of boiler and distribution system. In this case, it is required to have investment on infrastructure for the supply of new heating oil (mixture of gasoline and B-C oil) and a proper preparatory period for the conversion of equipment (such as a boiler). The vitalization of storing oil is essential to stabilize the supply and demand of heating oil. In order to vitalize it, the price of heating oil should be determined by a market function reflecting the seasonal supply and demand circumstances. (author). 101 refs., 5 figs., 83 tabs.

  16. A Direct Heat Exchanger Unit used for Domestic Hot Water Supply in a Single-family House Supplied by Low Energy District Heating

    DEFF Research Database (Denmark)

    Brand, Marek; Thorsen, Jan Eric; Svendsen, Svend

    2010-01-01

    The increasing number of new and renovated buildings with reduced heating requirements will soon make traditional District Heating (DH) systems uneconomic. To keep DH competitive in the future, the heat loss in DH networks needs to be reduced. One option is to reduce the supply temperature of DH...... as much as possible. This requires a review of the behaviour of the whole domestic hot water (DHW) supply system with focus on the user comfort and overall costs. This paper describes some practical approaches to the implementation of this Low Energy District Heating (LEDH) concept. It reports...... on the testing of the dynamic behaviour of an Instantaneous Heat Exchanger Unit(IHEU) designed for DHW heating and space heating in detached family houses supplied by LEDH ensuring an entry-to-substation temperature of 51 °C. We measured the time it takes for the IHEU to produce DHW with a temperature of 42 °C...

  17. The economics of supplying the supplementary heat in a closed loop water source heat pump system

    International Nuclear Information System (INIS)

    Johnson, R.P.; Bartkus, V.E.; Singh, J.B.

    1993-01-01

    The paper describes the details of a research and demonstration project that will be completed in August 1992 at a healthcare facility in northeastern Pennsylvania. The purpose of the project is to compare the economics of several methods of supplying the supplementary heating in a facility served by a closed loop water source heat pump system. The systems being tested include a storage hot water tank with electric resistance heaters and three air source heat pumps that have the ability to supply the same heat during on-peak hours as well as off-peak hours. The paper compares the projected operating costs of the following: (1) Gas boiler supplying the supplementary heat. (2) Stored hot water supplying the supplementary heat which is generated and stored during off-peak hours using resistance heat on PP ampersand L's offpeak rate. (3) Stored hot water supplying the supplementary heat generated during off-peak hours using the air source heat pumps on PP ampersand L's off-peak rate. (4) Hot water generated by the air source heat pumps supplying the supplementary loop heating on PP ampersand L's general service and time-of-day electric rates. It is generally known in the HVAC industry that a closed loop water source heat pump system can provide one of the most efficient means of space conditioning to a building with high internal gains by transferring the excess heat available in one part of the building to another part of the building where it may be needed for heating. The following flow diagram depicts the relationship of the air source heat pumps with the storage tanks and the building closed water loop

  18. Heat supply of the town of Trnava from EBO nuclear plant

    International Nuclear Information System (INIS)

    Kovarik, Z.

    4 variants of central heat supply from the V-2 Bohunice nuclear power plant were considered. Three included the supply of hot water while the fourth envisaged the supply of steam. The variants of hot water supply differed in the proportion of heat supply during load peak, the range being from 75% to 88% to 100%. The system suggested considers hot water with a maximum overpressure of 2.5 MPa and temperature of 150/70 degC, with possible temporary decrease to 130/70 degC. The estimated power of heat exchange stations is 240 MW at a temperature gradient of 150/70 degC and 180 MW at a temperature gradient 130/70 degC. The location, design and control of the heat supply system and the specifications of heat generation facilities are given. (J.P.)

  19. Analysis of trends in the development of cities' heat supply systems

    Science.gov (United States)

    Stennikov, V. A.; Mednikova, E. E.

    2016-09-01

    New challenges—including the modern urban development policy, formation of the market of energy efficient technologies and different types of equipment of a broad power capacity range, tightening requirements to reliability, quality, and economic accessibility of heat supply—enhance the competitiveness of decentralized heat supply. In addition, its spontaneous growth and not always reasonable implementation lead to unjustified expenses, low efficiency, and ecological inconsistency. This proves the relevance of solving the problems of dividing an urban territory into zones of centralized heating (CH) and decentralized heating (DCH) along with their planning and justification, as well as determining a reasonable level of heat supply centralization and concentration of heat sources' power capacity. Solving these problems using the suggested method will allow optimizing the application areas for various types of heat supply and heat sources, justifying the degree of heat power capacity concentration and the extent of the systems as early as at the phase of a detailed urban planning project and then refining them during the design of urban heat supply systems. This will dramatically improve the reasonability of the decisions made and will simplify the procedure of their implementation. For criteria of limiting the extent (radius) of heat supply systems and defining their type, we suggest using standard values—the density of heat load per unit length of the pipeline and per unit area of urban territory. Standard values must be differentiated across the territory of Russia taking into account regional climatic and economic conditions and unique characteristics of heat supply development in cities and towns. The present article continues and develops the statements made in the previous articles created within the framework of the Theory of Hydraulic Circuits and takes into account the current situation and emerging trends in heat supply.

  20. Proposal for a district heat supply system

    International Nuclear Information System (INIS)

    Alefeld, G.

    1976-01-01

    A district heating scheme is proposed which makes it possible to use the waste heat from power stations for the supply of households and industry. The heat is stored by evaporation of ammonia salts or liquids with dissolved salts. Both substances are transported on existing rail- or waterways to heating stations near the consumers, and the heat recovered by reaction of the two components. Then the product of reaction is transported back to the power stations, and reactivated by heat again. Based on a cost estimation, it can be shown that the proposed heat transport with heat trains or ships, at distances up to 100 km, results in heat costs which are to-day already below that of heat from fuel oil. The investment required for the heat transport system is unusually low due to the use of transport ways which already exist. The district heating system is not only favourable in respect of the environment, but actually reduces its present strain, both at the consumer and at the power stations. The technical advantages of the suggested concept, especially the possibility of introducing it in stages, are discussed. The consequences for the national economy regarding the safety of supply and the trade balance, as well as for the public transport undertakings, are obvious, and therefore not included in the paper. (orig.) [de

  1. Use of aqua ammonia solution for long distant heat supply from NPP

    International Nuclear Information System (INIS)

    Stolyarevskij, A.Ya.; Fedotov, I.L.; Verkhivker, G.P.

    1989-01-01

    Feasibility study of aqueous-ammonia heat supply systems is presented in brief. Temperature NPP heat is the energy source. It is shown that application of such systems, using industrial waste heat, is more expedient, than application of traditional two-tube heat supply system. Heat supply system without use of waste heat of a consumer is competitive if distances from a consumer exceed 60 km. Heat transfer coefficient of such systems can achieve 90-92%

  2. Initiative for local district heating. New chances for municipal utilities. Boundary conditions for the heat market; Initiative Nahwaerme. Neue Chancen fuer Stadtwerke. Rahmenbedingungen fuer den Waermemarkt

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Michael [K.Group GmbH, Muenchen (Germany). Bereich Nachhaltige Energieversorgung und Stadtentwicklung

    2009-06-15

    In the regulated market, municipal utilities are forced to find new fields of activity. The heat market offers good chances. For example, local district heating grids can be established, independent power generation can be encouraged, and new services can be offered which may increase customer loyalty. The district heating initiative of the Baden-Wuerttemberg Minister of the Environment was launched early in 2009 with the intention to offer valuable assistance to the municipal utilities. (orig.)

  3. SELECTION OF HEAT SUPPLY SOURCE FOR MOBILE BUILDING STRUCTURE

    Directory of Open Access Journals (Sweden)

    T. I. Dolgikh

    2014-01-01

    Full Text Available The paper proposes a vortex heat generator with energy transformation of the highest  state  of matter motion  into  the  lowest  one  as  a  heat  supply  source  for a mobile object. Energy transformation coefficient indices close or equal to 1 have been obtained as a result of experiments on efficiency of the vortex heat generator. Such results can be explained with the help of the 2nd Bohr quantum postulate. Standard series of certified VTG heat generators has been proposed for heat supply of the mobile object (field hospital.

  4. Target study of heat supply from Northern Moravia nuclear power plant

    International Nuclear Information System (INIS)

    Pospisil, V.

    The construction is envisaged in Northern Moravia of a nuclear power plant near Blahutovice in the Novy Jicin district. Heat produced by the nuclear power plant will only be used for district heating; process heat will be supplied from local steam sources. An example is discussed of the Prerov locality which currently is supplied from the Prerov heating and power plant (230 MW), a heating plant (36 MW) and from local sources (15 NW). The study estimates that a thermal power of 430 MW will be required at a time of the start of heat supplies from the nuclear power plant. All heat supply pipelines will be designed as a two-tube system divided into sections with section pipe fittings. The number and location of pipe fittings will be selected depending on the terrain configuration. Water of the maximum outlet temperature of 150 degC will be used as a coolant. The control of the system for Northern Moravia is briefly described. (J.P.)

  5. Renewable-based heat supply of multi-apartment buildings with varied heat demands

    International Nuclear Information System (INIS)

    Truong, Nguyen Le; Dodoo, Ambrose; Gustavsson, Leif

    2015-01-01

    This study investigates the cost and primary energy use to heat an existing multi-apartment building in Sweden, before and after deep energy efficiency renovation, with different types of renewable-based systems. District heating systems of different scales as well as local heat production based on bioelectric boilers, ground-source bioelectric heat pumps and wood pellet boilers with or without solar heating are considered. The annual energy demand of the building, calculated hour by hour, with and without energy efficiency improvements, are matched against the renewable-based heat supply options by techno-economic modeling to minimize cost for each considered heat supply option. The results show that the availability of heating technologies at the building site and the scale of the building's heat demand influence the cost and the primary energy efficiency of the heating options. District heat from large-scale systems is cost efficient for the building without energy-efficiency improvement, whereas electric heat pumps and wood pellet boilers are more cost efficient when implementing energy-efficiency improvement. However, the cost difference is small between these alternatives and sensitive to the size of building. Large-scale district heating with cogeneration of power is most primary energy efficient while heat pumps and medium-scale district heating are nearly as efficient. - Highlights: • Heating technologies influence costs and primary energy use of a building. • Large-scale district heating with cogeneration of power is primary energy efficient. • Large-scale district heating is cost efficient for buildings with large heat demand. • Heat pumps and pellet boilers are cost competitive in energy-efficient buildings.

  6. Swedish district heating - owners, prices and profitability

    International Nuclear Information System (INIS)

    Andersson, Sofie; Werner, S.

    2001-01-01

    Owners, prices and profitability are examined in this report for 152 Swedish district heating companies during 1999. Only public information available has been used: Prices from a national annual consumer study, energy supplied, lengths of district heating pipes installed, and average prices for energy supplied. These companies are responsible for 96 % of all district heat supplied in Sweden. District heating systems owned by municipalities were responsible for 65 % of all district heat supply, while the share of power companies was 34 %. Other private owners accounted for 1 %. Only 12 % of the board members are women and more than 40 % of the companies have no woman in the board. The prices gathered by the annual consumer study are good estimates of the price level of district heating in Sweden. The average revenues are only 4,1 % lower than the effective average of prices gathered. Price of district heating decrease with size and market share. Use of combined heat and power plants decrease prices slightly. Lower prices with size can mainly be explained by lower energy supply costs. Calculated rates of return in relation to calculated replacement values increase slightly by size and are almost independent of age and market share. The purport of these conclusions is that the district heating companies share the cost reduction from size with their customers, while the whole benefit from high market shares is repaid to the customers. Calculated rates of return vary among the owner groups examined. Lower rates are accepted by municipalities, while power companies have higher rates at the average costs used. Total replacement costs for the 152 companies has been estimated to 89 billion Swedish crowns or 10 billion Euro. Only correlation analyses using one dimension have been used in this study. A higher degree of quality can be obtained by using multi-dimensional analyses

  7. HEAT LOSS FROM HOT WATER SUPPLY LINE IN A RESIDENTIAL BUILDING

    OpenAIRE

    近藤, 修平; 鉾井, 修一

    2011-01-01

    In order to the evaluate heat loss from hot water supply lines in a residential building, hot water demand in a house in Chiba prefecture was measured and analyzed. The following results were obtained. 1. The heat loss of the hot water supply line was about 132kJ for the shower and 110kJ for the bathtub in winter. Since the temperature difference between the inlet and outlet of the hot water supply line is small, the measured heat loss from the hot water supply line sometimes becomes negative...

  8. Life cycle assessment of a commercial rainwater harvesting system compared with a municipal water supply system

    Science.gov (United States)

    Building upon previously published life cycle assessment (LCA) methodologies, we conducted an LCA of a commercial rainwater harvesting (RWH) system and compared it to a municipal water supply (MWS) system adapted to Washington, D.C. Eleven life cycle impact assessment (LCIA) indi...

  9. Report of testing and sampling of municipal supply well PM-4

    International Nuclear Information System (INIS)

    Koch, Richard J.; Longmire, Patrick; Rogers, David B.; Mullen, Ken

    1999-01-01

    During drilling of regional aquifer characterization borehole R-25, located in the western part of Los Alamos National Laboratory (LANL) at Technical Area (TA) 16, groundwater samples were collected from perched zones of saturation and the regional aquifer that contained elevated levels of high explosive (HE) compounds. One of the nearest Los Alamos County municipal supply wells potentially located down gradient from borehole R-25 is PM-4, located on Mesita del Buey at the west end of TA-54. During the winter of 1998 and 1999 the pump in PM-4 had been removed from the well for scheduled maintenance by the Los Alamos County Public Utilities Department (PUD). Because the pump was removed from PM-4, the opportunity existed to enter the well to (1) perform tests to determine where within the regional aquifer groundwater entered the well and (2) collect groundwater samples from the producing zones for analyses to determine if HE contaminants were present in discrete zones within the regional aquifer. The report of the activities that were performed during March 1999 for the testing and sampling of municipal supply well PM-4 is provided. The report provides a description of the field activities associated with the two phases of the project, including (1) the results of the static and dynamic spinner log surveys, and (2) a description of the sampling activities and the field-measured groundwater quality parameters that were obtained during sampling activities. This report also provides the analytical results of the groundwater samples and a brief discussion of the results of the project

  10. Researching of the possibility of using absorption heat exchangers for creating the low return temperature heat supply systems based on CHP generation

    Science.gov (United States)

    Yavorovsky, Y. V.; Malenkov, A. S.; Zhigulina, Y. V.; Romanov, D. O.; Kurzanov, S. Y.

    2017-11-01

    This paper deals with the variant of modernization of the heat point within urban heat supply network in order to create the system of heat and cold supply on its basis, providing the suppliers with heat in cold months and with heat and cold in warm months. However, in cold months in the course of heating system operation, the reverse delivery water temperature is maintained below 40 °C. The analysis of heat and power indicators of the heat and cold supply system under different operating conditions throughout the year was conducted. The possibility to use the existing heat networks for the cold supply needs was estimated. The advantages of the system over the traditional heat supply systems that use Combined Heat and Power (CHP) plant as a heat source as exemplified by heat supply system from CHP with ST-80 turbine were demonstrated.

  11. The potential to supply low temperature district heating to existing building area

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    2013-01-01

    Low-temperature district heating (LTDH) has the advantages as reduced network heat loss, improved quality match between energy supply and energy demand, and increased utilization of low-grade waste heat and renewable energy. The LTDH represents the next generation district heating (DH) system...... to supply existing building areas which are characterized with high heating demand needs to be examined. In this paper, the DH network deliverable capacity to supply LTDH to an existing building area is studied based on building thermal performance and DH network hydraulic performance simulation....

  12. HEAT SUPPLY SYSTEM IMPROVEMENT OF CAMPUS AT UMAN NATIONAL UNIVERSITY OF HORTICULTURE

    Directory of Open Access Journals (Sweden)

    A. F. Golovchuk

    2016-06-01

    Full Text Available Purpose. In modern conditions of energy consumption growth and a rapid increase in energy prices the actual problem is the development and implementation of energy efficiency programs and resource-saving conversion in to a source to provide the needs of industry and municipal power. The paper aims to solve the urgent problem of energy saving and efficient use of fuel-energy ones and heat supply system optimization on the basis of Uman National University of Horticulture (UNUH. Methodology. The work investigated the process of heating and hot water supply in the course of 2007-2015 years. Implementation of current problems of energy saving is grounded on the scientific-practical and efficient assurance of fuel and energy usage. At the same time energy-saving technologies are viewed as a priority direction of the energy sector development, reduction of man-induced impact on the environment and as a way of improving the competitiveness of the national economy. Findings. Statistical data acquisition and analyzing of gas flow and outside air temperature for nine years was carried out. On the basis of this analysis, the problem was identified and specific targets for its solutions were set. Originality. Scientific novelty lies in solving the problem of energy saving and efficient use of fuel resources in Ukraine through the use of a systematic approach, the methodology development of efficient use of different fuels and optimization of local heating operation, applying contemporary automation and control systems. Firstly it was in detail analyzed and conducted the comprehensive assessment of various factors influence on energy conservation. It takes into account the human factor, professionalism and responsibility of the operators of boilers and their superiors, as well as the relevant control services. Practical value. For UNUH campus hybrid use of solid fuel and gas boilers was carried out. Decentralization of the university heating system has been

  13. About opportunities of the sharing of city infrastructure centralized warmly - and water supply

    Science.gov (United States)

    Zamaleev, M. M.; Gubin, I. V.; Sharapov, V. I.

    2017-11-01

    It is shown that joint use of engineering infrastructure of centralized heat and water supply of consumers will be the cost-efficient decision for municipal services of the city. The new technology for regulated heating of drinking water in the condenser of steam turbines of combined heat and power plant is offered. Calculation of energy efficiency from application of new technology is executed.

  14. Municipal responses to the energy challenge: Nysted, Denmark. Innovation and retreat in a rural municipality

    Energy Technology Data Exchange (ETDEWEB)

    Woodward, A E

    1985-01-01

    This case study is one of a series describing the social and organizational processes behind municipal innovation in energy planning, conservation and supply. Nysted in Denmark provides an example of both the potential and the limitations on innovation in energy in a small-town environment. The community sponsored an innovative planning project which has since become a model for Danish community energy inventory studies and planning. Further, many individuals in Nysted adapted their heating or electrical supply systems for the use of renewable fuels, especially wind and straw. The community relied on outside expertise and was confronted with the classic problem of transition and implementation when the consultants left. Nysted amply illustrates the dilemma of small communities faced with modern technological problems and limited technological resources.

  15. Optimal usage of low temperature heat sources to supply district heating by heat pumps

    DEFF Research Database (Denmark)

    Pieper, Henrik; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    This paper presents a theoretical study on the optimal usage of different low temperature heat sources to supply district heating by heat pumps. The study is based on data for the Copenhagen region. The heat sources were prioritized based on the coefficient of performance calculated for each hour...... and the covered demand of each heat source as well as required peak unit capacity. The results showed that heat pumps using different heat sources yield better performance than a heat pump based on a single one. The performance was influenced by the composition of the different heat sources. It was found that 78......% groundwater, 22% seawater and 0% air resulted in highest COP of 3.33 for the given heat demand. Furthermore, the implementation of rule based short term storage made peak units redundant. The variation in base load capacity showed that heat pumps utilizing the analyzed heat sources could perform very...

  16. Waterborne norovirus outbreak in a municipal drinking-water supply in Sweden.

    Science.gov (United States)

    Riera-Montes, M; Brus Sjölander, K; Allestam, G; Hallin, E; Hedlund, K-O; Löfdahl, M

    2011-12-01

    During Easter 2009, almost 200 people resident in a small Swedish village fell ill with gastrointestinal symptoms. We conducted a retrospective cohort study and a molecular investigation in order to identify the source of the outbreak. Residents living in households connected to the public water network were at an increased risk of developing disease (relative risk 4·80, 95% confidence interval 1·68-13·73) compared to those with no connection to the public network. Norovirus genotype GI.3 was identified in stool samples from six patients and in a sample from the public water network. Contamination of one of the wells supplying the public water network was thought to be the source of the outbreak. This is a description of a norovirus outbreak linked to a municipal drinking-water supply in Sweden. Information from epidemiological and molecular investigations is of utmost importance to guide outbreak control measures and to prevent future outbreaks.

  17. Master plan study - District heating Kohtla-Jaerve and Johvi municipalities. Estonia. Final report. Appendices for chapter 9

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The appendices to chapter nine of the final report of the master plan study on district heating in the municipalities of Kohtla-Jarve and Johvi municipalities (Estonia) present extensive data relating to economic, financial and environmental calculations, fuel consumption, energy balance and prices. (ARW)

  18. Internalising external costs of electricity and heat production in a municipal energy system

    International Nuclear Information System (INIS)

    Holmgren, Kristina; Amiri, Shahnaz

    2007-01-01

    Both energy supply and waste treatment give rise to negative effects on the environment, so-called external effects. In this study, monetary values on external costs collected from the EU's ExternE project are used to evaluate inclusion of these costs in comparison with an energy utility perspective including present policy instruments. The studied object is a municipal district heating system with a waste incineration plant as the base supplier of heat. The evaluation concerns fuels used for heat production and total electricity production, for scenarios with external costs included and for a scenario using the present policy instrument. Impacts of assumptions on marginal power producers (coal or natural gas power plants) are investigated, since locally produced electricity is assumed to replace marginal power and thus is credited for the avoided burden. Varying levels of external costs for carbon dioxide emissions are analysed. The method used is an economic optimisation model, MODEST. The conclusion is that present policy instruments are strong incentives for cogeneration, even when external costs are included. Waste is fully utilised in all scenarios. In cases where coal is the marginal power producer, more electricity is produced; when natural gas is the marginal power producer, less is produced. There are several uncertainties in the data for external costs, both methodological and ethical. In the ExternE data, not all environmental impacts are included. For waste incineration, ashes are not included, and another difficulty is how to treat the avoided burden of other waste treatment methods

  19. Dream aim reached: 1300 operational district heating supply connections

    Energy Technology Data Exchange (ETDEWEB)

    Handl, K H

    1988-11-01

    Only four years after the beginning of operation of the first consumer station at Klingnau on October 19, 1984, the Regional District Heating Supply in the Lower Aare Valley (Refuna) can already show 1295 operational district heating connections. There are almost 300 more than one year ago and about 20% more than originally foreseen during this short construction time. As in recent years, the number of consumers has significantly increased during a 'connection boom' in the first autumn weeks. The total heat supply power amounts to 51500 kilowatts. This is 70% of the power foreseen in the final stage. 3 figs., 1 tab.

  20. ENERGY-EFFICIENT REGIMES FOR HEATING-SUPPLY OF THE RESIDENTIAL BUILDINGS

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2015-01-01

    Full Text Available Rise in comfort and inhabitation safety is one of the main requirements of the general maintenance, reconstruction of the old and construction of the new residential houses. One of the essential factors of it is substitution in the household hot-water preparing sources: from the individual domestic gas  water-heaters to  the common  entire-building hot-water supply at the expense of the centralized heat supply. Extremely erratic hot-water daily consumption by tenants leads to the necessity of sharp increase in central heat-supply level during a few hours of the day, which requires a significant increase of the source heat-power. On that score, the authors propose to direct a significant part (up to 50 % of the centralized heating and ventilation heat power-consumption to the hot water preparation during the period of short-term hot water consumption peak.Substitution  of  the  individual  domestic  gas  water-heaters  with  the  common  entirebuilding hot-water supply releases a huge amount of natural gas which can be utilized not only for production of the necessary heat power but as well for electric power producing. This substitution is especially advantageous if heat-power is delivered to the residential area from a НРС where significant part of heat especially in a relatively warm season of the year is thrown out into the air. The content of the article is based on several patents received earlier.

  1. An experimental study on defrosting heat supplies and energy consumptions during a reverse cycle defrost operation for an air source heat pump

    International Nuclear Information System (INIS)

    Dong Jiankai; Deng Shiming; Jiang Yiqiang; Xia Liang; Yao Yang

    2012-01-01

    For a space heating air source heat pump (ASHP) unit, when its outdoor coil surface temperature is below both the air dew point temperature and the freezing point of water, frost will form on its outdoor coil surface. Frosting affects its operational performance and energy efficiency. Therefore, periodic defrosting is necessary. Currently, the most widely used standard defrosting method for ASHP units is reverse cycle defrost. The energy that should have been used for space heating is used to melt frost, vaporize the melted frost off outdoor coil surface and heat ambient air during defrosting. It is therefore necessary to study the sources of heat supplies and the end-uses of the heat supplied during a reverse cycle defrost operation. In this paper, firstly, an experimental setup is described and experimental procedures are detailed. This is followed by reporting the experimental results and the evaluation of defrosting efficiency for the experimental ASHP unit. Finally, an evaluation of defrosting heat supplies and energy consumptions during a revere cycle defrost operation for the experimental ASHP unit is presented. The experimental and evaluation results indicated that the heat supply from indoor air contributed to 71.8% of the total heat supplied for defrosting and 59.4% of the supplied energy was used for melting frost. The maximum defrosting efficiency could be up to 60.1%. - Highlights: ► Heat supply and consumption during reverse cycle defrost was experimentally studied. ► Indoor air contributed to >70% of total heat supply when indoor fan was turned on. ► ∼60% of the supplied energy was used for melting frost. ► Alternate heat supply other than indoor air should be explored.

  2. Monitoring of Hazardous Inorganic Pollutants and Heavy Metals in Potable Water at the Source of Supply and Consumers end of a Tropical Urban Municipality

    International Nuclear Information System (INIS)

    Shah, A. B.; Singh, R. P.

    2016-01-01

    River water is not only an indispensable source for irrigation but also plays a vital role for drinking water supply for most of the urban municipalities. Water from rivers is pumped at specific sites and after treatment at municipal water treatment plants supplied as domestic potable water supply. The present study was undertaken to assess the suitability of Gomti river water at Gaughat being used as the source of water supply for Lucknow city and to evaluate post-treatment potable water quality at the consumer end by monitoring the levels of inorganic pollutants (nitrate, nitrite, ammonium and phosphate) and heavy metals. Municipal water supply at Gaughat showed marked variations in the levels of p H (7.13-8.63) and electrical conductivity (375.66-571.67μS/cm). The amount of nitrate, nitrite, ammonium and phosphate was observed 26.25, 0.082, 6.9 and 1.82 mg/l respectively at Gaughat. Also, the levels of heavy metals in the municipal water source at Gaughat varied significantly for Fe (0.33-1.65 mg/l), Cu (0.077-0.108 mg/l), Cd (0.03-0.052 mg/l), Pb (0.68-0.96 mg/l) and Cr (0.036-0.065 mg/l). Water at the user end was also contaminated as the concentration of analysed inorganic pollutants and heavy metals were correspondingly higher than observed at the source. While comparing potable water at the user end of Lucknow municipality with the BIS (Drinking Water Specifications) and WHO standards for drinking water, the concentration of all studied heavy metals and other inorganic contaminants were much above the permissible levels, thus posing a serious threat to the public health.

  3. District heating in Switzerland: Giving a survey and studying an example case

    Energy Technology Data Exchange (ETDEWEB)

    Kiss, M; Minder, R

    1981-05-01

    Today it is generally accepted that district-heating has essential adventages in areas which are suitable for it - as opposed to the heating mode which is most widely practiced in Switzerland, i.e. individual oil heating. These advantages shall only be pointed out briefly, here, by mentioning the following key words: economy, exploitation of fuel, safety of supply, and enviromental protection. Principally supporting the expansion of existing district-heating installations or the construction of new ones the authors give their view on the subject concerning the contribution to the total supply of heat which reasonably may be attributed to district-heating; they also give their opinion of the plans of a Swiss municipality as to its energy and district-heating supply.

  4. FOLA - the district heat supply project for the Olten-Aarau region

    International Nuclear Information System (INIS)

    Utzinger, E.

    1986-01-01

    The FOLA project envisages supply of nuclear power station heat via pipe lines to communities in the Olten-Aarau region. The project is introduced with reference to environmental and oil saving advantages. Heat from the nuclear power station steam circuit converted via heat exchangers would be transmitted through pressurised hot water pipe line networks to user communities for extraction by heat exchangers at consumer installations. Some network details are discussed. The exact supply area is not yet finalised, but estimated heat loading is about 150 MW. Following further studies a construction and operating company could be formed, and heat delivery could commence in 1989. (H.V.H.)

  5. Estimation of transient heat flux density during the heat supply of a catalytic wall steam methane reformer

    Science.gov (United States)

    Settar, Abdelhakim; Abboudi, Saïd; Madani, Brahim; Nebbali, Rachid

    2018-02-01

    Due to the endothermic nature of the steam methane reforming reaction, the process is often limited by the heat transfer behavior in the reactors. Poor thermal behavior sometimes leads to slow reaction kinetics, which is characterized by the presence of cold spots in the catalytic zones. Within this framework, the present work consists on a numerical investigation, in conjunction with an experimental one, on the one-dimensional heat transfer phenomenon during the heat supply of a catalytic-wall reactor, which is designed for hydrogen production. The studied reactor is inserted in an electric furnace where the heat requirement of the endothermic reaction is supplied by electric heating system. During the heat supply, an unknown heat flux density, received by the reactive flow, is estimated using inverse methods. In the basis of the catalytic-wall reactor model, an experimental setup is engineered in situ to measure the temperature distribution. Then after, the measurements are injected in the numerical heat flux estimation procedure, which is based on the Function Specification Method (FSM). The measured and estimated temperatures are confronted and the heat flux density which crosses the reactor wall is determined.

  6. Heating and Domestic Hot Water Systems in Buildings Supplied by Low-Temperature District Heating

    DEFF Research Database (Denmark)

    Brand, Marek

    solutions simply redirect the bypassed water back to the DH network without additional cooling, but bypassed water can instead be redirected to floor heating in the bathroom to be further cooled and thus reduce heat loss from the DH network while improving comfort for occupants and still ensure fast DHW...... increased risk of Legionella if the DH substation and DHW system are designed for the low-temperature supply conditions. To ensure the fast provision of DHW during non-heating periods, the supply service pipe should be kept warm, preferably with the bypass solution redirecting the bypass flow to bathroom...... temperature. To accord with the literature, the modelling of internal heat gains reflected the improved efficiency of equipment by reduction of value from 5W/m2 to 4.2W/m2, also modelled as intermittent heat gains based on a realistic week schedule. Furthermore, the indoor set-point temperature was increased...

  7. Combined installation of electric and heat supply for climatic conditions of Iraq

    Science.gov (United States)

    Kaisi, Osama Al; Sidenkov, D. V.

    2017-11-01

    Electricity, heating and cooling are the three main components that make up the energy consumption base in residential, commercial and public buildings around the world. Demand for energy and fuel costs are constantly growing. Combined cooling, heating and power generation or trigeneration can be a promising solution to such a problem, providing an efficient, reliable, flexible, competitive and less harmful alternative to existing heat and cold supply systems. In this paper, scheme of the tri-generation plant on non-aqueous working substances is considered as an installation of a locally centralized electro-heat and cold supply of a typical residential house in a hot climate. The scheme of the combined installation of electro-heat (cold) supply consisted of the vapor power plant and heat pump system on low-boiling working substance for local consumers under the climatic conditions of Iraq is presented. The possibility of using different working substances in the thermodynamic cycles of these units, which will provide better efficiency of such tri-generation systems is shown. The calculations of steam turbine cycles and heat pump part on the selected working substances are conducted. It is proposed to use heat exchangers of plate type as the main exchangers in the combined processing. The developed method of thermal-hydraulic calculation of heat exchangers implemented in MathCad, which allows to evaluate the efficiency of plants of this type using the ε - NTU method. For the selected working substances of the steam part the optimal temperature of heat supply to the steam generator is determined. The results of thermodynamic and technical-economic analysis of the application of various working substances in the “organic” Rankine cycle of the steam turbine unit and the heat pump system of the heat and cold supply system are presented.

  8. Current contributions on the technical thermodynamics, power engineering and district heating supply. Special publication; Aktuelle Beitraege zur technischen Thermodynamik, Energietechnik und Fernwaermeversorgung. Sonderveroeffentlichung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-03-15

    Within the special publication under consideration, the German Heat and Power Association (Frankfurt (Main), Federal Republic of Germany) presents the following current contributions on the technical thermodynamics, power engineering and district heating supply: (1) Cellular metallic materials for innovative latent heat accumulator technologies (Jens Meinert); (2) Compressed air storage - technology, chances and problems (Rutger Kretschmer); (3) KWK electricity - Identification and evaluation (Matthias Krause); (4) Investigation of the storage ability of district heating grids and implementation into the optimized planning of heat generators (Sebastian Gross); (5) Autarcic thermal densification to the combined heat and power and cooling production? - A fundamental thermodynamic consideration (Torben Moeller); (6) Modelling of cogeneration power plants - Investigation of the transformation opportunity of existing district heating systems in LowEx grids (Martin Rhein); (7) Discrete building model for the dynamic thermohydraulic simulation of district heating (Dominik Haas); (8) Ventilation and degasification of solar power plants (Karin Ruehling); (9) Integral simulation of district heating with TRNSYS-TUD (Steffen Robbi); (10) Theoretical analyses of return temperatures in building heating networks (Andreas Meinzenbach); (11) Municipal energy efficiency as an important contribution to the reduction of greenhouse gas emissions (Matthias Mischke); (12) Investigation of the latent heat storage system PK 6 for use in air-conditioning installations (Sebastian Pinnau); (13) The role of the thermodynamics in the electromobility (Lars Schinke); (14) Flow and heat transfer in cooling channels with methane (Andre Schlott); (15) Numerical calculations of stoves fired with wooden logs (Ulf Senechal); (16) Supply of thermodynamic substance data for working fluids of power engineering (Hans-Joachim Kretzschmar); (17) Cyclic pipe-ground interaction in solar-thermal heat grids

  9. Use of multilevel modeling for determining optimal parameters of heat supply systems

    Science.gov (United States)

    Stennikov, V. A.; Barakhtenko, E. A.; Sokolov, D. V.

    2017-07-01

    The problem of finding optimal parameters of a heat-supply system (HSS) is in ensuring the required throughput capacity of a heat network by determining pipeline diameters and characteristics and location of pumping stations. Effective methods for solving this problem, i.e., the method of stepwise optimization based on the concept of dynamic programming and the method of multicircuit optimization, were proposed in the context of the hydraulic circuit theory developed at Melentiev Energy Systems Institute (Siberian Branch, Russian Academy of Sciences). These methods enable us to determine optimal parameters of various types of piping systems due to flexible adaptability of the calculation procedure to intricate nonlinear mathematical models describing features of used equipment items and methods of their construction and operation. The new and most significant results achieved in developing methodological support and software for finding optimal parameters of complex heat supply systems are presented: a new procedure for solving the problem based on multilevel decomposition of a heat network model that makes it possible to proceed from the initial problem to a set of interrelated, less cumbersome subproblems with reduced dimensionality; a new algorithm implementing the method of multicircuit optimization and focused on the calculation of a hierarchical model of a heat supply system; the SOSNA software system for determining optimum parameters of intricate heat-supply systems and implementing the developed methodological foundation. The proposed procedure and algorithm enable us to solve engineering problems of finding the optimal parameters of multicircuit heat supply systems having large (real) dimensionality, and are applied in solving urgent problems related to the optimal development and reconstruction of these systems. The developed methodological foundation and software can be used for designing heat supply systems in the Central and the Admiralty regions in

  10. Dynamic Heat Supply Prediction Using Support Vector Regression Optimized by Particle Swarm Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Meiping Wang

    2016-01-01

    Full Text Available We developed an effective intelligent model to predict the dynamic heat supply of heat source. A hybrid forecasting method was proposed based on support vector regression (SVR model-optimized particle swarm optimization (PSO algorithms. Due to the interaction of meteorological conditions and the heating parameters of heating system, it is extremely difficult to forecast dynamic heat supply. Firstly, the correlations among heat supply and related influencing factors in the heating system were analyzed through the correlation analysis of statistical theory. Then, the SVR model was employed to forecast dynamic heat supply. In the model, the input variables were selected based on the correlation analysis and three crucial parameters, including the penalties factor, gamma of the kernel RBF, and insensitive loss function, were optimized by PSO algorithms. The optimized SVR model was compared with the basic SVR, optimized genetic algorithm-SVR (GA-SVR, and artificial neural network (ANN through six groups of experiment data from two heat sources. The results of the correlation coefficient analysis revealed the relationship between the influencing factors and the forecasted heat supply and determined the input variables. The performance of the PSO-SVR model is superior to those of the other three models. The PSO-SVR method is statistically robust and can be applied to practical heating system.

  11. Master plan study - District heating Sillamaee municipality. Estonia. Final report. Appendices for chapter 9

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The appendices to the final report on the master plan study on district heating in the municipality in Estonia, chapter nine, gives data related to general economic assumptions for financial and economic calculations, fuel consumption, financing, prices, fuel consumption. (ARW)

  12. District heating in sequential energy supply

    International Nuclear Information System (INIS)

    Persson, Urban; Werner, Sven

    2012-01-01

    Highlights: ► European excess heat recovery and utilisation by district heat distribution. ► Heat recovery in district heating systems – a structural energy efficiency measure. ► Introduction of new theoretical concepts to express excess heat recovery. ► Fourfold potential for excess heat utilisation in EU27 compared to current levels. ► Large scale excess heat recovery – a collaborative challenge for future Europe. -- Abstract: Increased recovery of excess heat from thermal power generation and industrial processes has great potential to reduce primary energy demands in EU27. In this study, current excess heat utilisation levels by means of district heat distribution are assessed and expressed by concepts such as recovery efficiency, heat recovery rate, and heat utilisation rate. For two chosen excess heat activities, current average EU27 heat recovery levels are compared to currently best Member State practices, whereby future potentials of European excess heat recovery and utilisation are estimated. The principle of sequential energy supply is elaborated to capture the conceptual idea of excess heat recovery in district heating systems as a structural and organisational energy efficiency measure. The general conditions discussed concerning expansion of heat recovery into district heating systems include infrastructure investments in district heating networks, collaboration agreements, maintained value chains, policy support, world market energy prices, allocation of synergy benefits, and local initiatives. The main conclusion from this study is that a future fourfold increase of current EU27 excess heat utilisation by means of district heat distribution to residential and service sectors is conceived as plausible if applying best Member State practice. This estimation is higher than the threefold increase with respect to direct feasible distribution costs estimated by the same authors in a previous study. Hence, no direct barriers appear with

  13. Power supply in future: ecological aspects

    International Nuclear Information System (INIS)

    Hustedt, M.

    2000-01-01

    The most important prerequisites for an ecological supply of energy in the future is the opting out of nuclear energy and the completion of the second and third phase of the socio-ecological tax reform. As a part of our energy will continue to be generated on the basis of fossil fuels in the foreseeable future, it is essential that a radical change takes place in the efficiency of fossil energy engineering. In addition to this, any possible energy-saving potential must be exploited; this includes the new energy-saving law, promoting the modernisation of old buildings and modern energy management (heat insulation, heating engineering, warm water heating etc.). For an ecological power supply the share of renewable energies must be increased to form a major pillar of our power supply. The '100,000-roof' programme of the German federal government and the development programme for near-market renewable energy sources form part of this approach. Energy research should shift its orientation and accelerate the conversion of our power supply: priority should be given to developing energy-saving technologies and renewable energy. Supporting municipalities and public utilities is especially important. This means revising the basic conditions of energy laws so that they assist public utilities to face competition as power utilities. (orig.) [de

  14. Natural gas and local heat supply. Erdgas und Nahwaerme

    Energy Technology Data Exchange (ETDEWEB)

    Berge, W. (Gasversorgungsgesellschaft Filstal mbH (Germany, F.R.) Stadtwerke Goeppingen (Germany, F.R.))

    Local heat supply consists of a thermal power station of a dual-purpose plant, a heat destribution system and the heating systems of the users. A combination of gas heat-pumps, cogeneration plant and gas turbine operated as basic load aggregates is a precondition for the flexible application of energy-saving though investment-intensive technologies. Several existing plants are described in order to explain the structure and functioning of various types of plants. (BWI).

  15. Integration of space heating and hot water supply in low temperature district heating

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Ommen, Torben Schmidt; Markussen, Michael

    2016-01-01

    District heating may supply many consumers efficiently, but the heat loss from the pipes to the ground is a challenge. The heat loss may be lowered by decreasing the network temperatures for which reason low temperature networks are proposed for future district heating. The heating demand...... of the consumers involves both domestic hot water and space heating. Space heating may be provided at low temperature in low energy buildings. Domestic hot water, however, needs sufficient temperatures to avoid growth of legionella. If the network temperature is below the demand temperature, supplementary heating...... is required by the consumer. We study conventional district heating at different temperatures and compare the energy and exergetic efficiency and annual heating cost to solutions that utilize electricity for supplementary heating of domestic hot water in low temperature district heating. This includes direct...

  16. Cold local heating. Agrothermal heat supply of an ecovillage; Kalt Nahwaerme. Agrothermische Waermeversorgung einer Plusenergiesiedlung

    Energy Technology Data Exchange (ETDEWEB)

    Pietruschka, Dirk [Hochschule fuer Technik Stuttgart (Germany). Forschungszentrum fuer Nachhaltige Energietechnik; Kluge, Juergen [Doppelacker GmbH, Petershagen-Eggersdorf (Germany)

    2013-03-01

    An ecovillage with highly efficient residential buildings is arisen in the Swabian community Wuestenrot. The power generation in these residential buildings by means of photovoltaic power plants is greater than the energy consumption. Decentralized heat plants supply thermal energy for the space heating and industrial waste. Central agrothermal collectors provide the necessary low-temperature heat for the effective operation of heat pumps over a so-called cold heat grid.

  17. Development of an innovative heat supply concept for a new housing area

    OpenAIRE

    Schmidt, Dietrich; Schurig, Marlen; Kallert, Anna; Orozaliev, Janybek; Best, Isabelle; Vajen, Klaus; Reul, Oliver; Bennewitz, Jochen; Gerhold, Petra

    2016-01-01

    The energy demand of buildings for heating and cooling is responsible for more than one third of the world's final energy consumption. Therefore the identification of innovative heat supply concepts based on renewable energies is required. The utilization of renewable energies in combination with efficient supply technologies increases the "sustainability" of new housing areas. For the new housing area "Zum Feldlager", located in Kassel (Germany), various supply concepts are investigated. Mai...

  18. Gaseous emissions during concurrent combustion of biomass and non-recyclable municipal solid waste.

    Science.gov (United States)

    Laryea-Goldsmith, René; Oakey, John; Simms, Nigel J

    2011-02-01

    Biomass and municipal solid waste offer sustainable sources of energy; for example to meet heat and electricity demand in the form of combined cooling, heat and power. Combustion of biomass has a lesser impact than solid fossil fuels (e.g. coal) upon gas pollutant emissions, whilst energy recovery from municipal solid waste is a beneficial component of an integrated, sustainable waste management programme. Concurrent combustion of these fuels using a fluidised bed combustor may be a successful method of overcoming some of the disadvantages of biomass (high fuel supply and distribution costs, combustion characteristics) and characteristics of municipal solid waste (heterogeneous content, conflict with materials recycling). It should be considered that combustion of municipal solid waste may be a financially attractive disposal route if a 'gate fee' value exists for accepting waste for combustion, which will reduce the net cost of utilising relatively more expensive biomass fuels. Emissions of nitrogen monoxide and sulphur dioxide for combustion of biomass are suppressed after substitution of biomass for municipal solid waste materials as the input fuel mixture. Interactions between these and other pollutants such as hydrogen chloride, nitrous oxide and carbon monoxide indicate complex, competing reactions occur between intermediates of these compounds to determine final resultant emissions. Fluidised bed concurrent combustion is an appropriate technique to exploit biomass and municipal solid waste resources, without the use of fossil fuels. The addition of municipal solid waste to biomass combustion has the effect of reducing emissions of some gaseous pollutants.

  19. SELECTION OF HEAT SUPPLY SOURCE FOR MOBILE BUILDING STRUCTURE

    OpenAIRE

    T. I. Dolgikh; S. V. Morozov; Yu. P. Orlov; A. B. Reis; A. Yu Yakovlev

    2014-01-01

    The paper proposes a vortex heat generator with energy transformation of the highest  state  of matter motion  into  the  lowest  one  as  a  heat  supply  source  for a mobile object. Energy transformation coefficient indices close or equal to 1 have been obtained as a result of experiments on efficiency of the vortex heat generator. Such results can be explained with the help of the 2nd Bohr quantum postulate. Standard series of certified VTG heat generators has been proposed for heat suppl...

  20. Economic feasibility of heat supply from simple and safe nuclear plants

    International Nuclear Information System (INIS)

    Tian, J.

    2001-01-01

    Use of nuclear energy as a heating source is greatly challenged by the economic factor since the nuclear heating reactors have relative small size and often the lower plant load factor. However, use of very simple reactor could be a possible way to economically supply heat. A deep pool reactor (DPR) has been designed for this purpose. The DPR is a novel design of pool type reactor for heat only supply. The reactor core is put in a deep pool. By only putting light static water pressure on the core coolant, the DPR will be able to meet the temperature requirements of heat supply for district heating. The feature of simplicity and safety of DPR makes a decrease of investment cost compared to other reactors for heating only purposes. According to the economical assessments, the capital investment to build a DPR plant is much less than that of a pressurized reactor with pressure vessels. For the DPR with 120 or 200 MW output, it can bear the economical comparison with a usual coal-fired heating plant. Some special means taken in DPR design make an increase of the burn-up level of spent fuel and a decrease of fuel cost. The feasibility studies of DPR in some cities in China show that heating cost using nuclear energy is only one third of that by coal and only one tenth of that by nature gas. Therefore, the DPR nuclear heating system provides an economically attractive solution to satisfy the demands of district heating without contributing to increasing greenhouse gas emissions

  1. Heat pipes as perspective base elements of heat recovery in heat supply and ventilating systems

    Directory of Open Access Journals (Sweden)

    Matveev Andrey

    2017-01-01

    Full Text Available Thermotechnical characteristics of heat pipes are considered as high-efficient heat-transfer devices, which can provide energy-saving technologies for heat supply and ventilating systems and for different branches of industry. Thermotechnical and working (”performance capability” characteristics of heat pipes are investigated. By ”performance capability” of heat pipes and heat-transfer devices on heat pipes we mean the system state, where it can perform set functions and keep parameter values (thermal power, conductivity, thermal resistance, heat-transfer coefficient, temperature level and differential, etc. within the regulations of standardized specifications. The article presents theoretical and experimental methods of «gaslock» length determination on noncondensable gases during long-lasting tests of ammonia heat pipes made of aluminum shape АS – КRА 7.5 – R1 (alloy АD – 31. The paper gives results of research of thermotechnical characteristics of heat pipes in horizontal and vertical states (separate and as a set part while using different systems of thermal insulation. The obtained results of thermotechnical and resource tests show the advantages of ammonia heat pipes as basic elements for heat exchanger design in heating and ventilation systems.

  2. Gas engine driven freon-free heat supply system complying with multiple fuels (eco-energy city project)

    Energy Technology Data Exchange (ETDEWEB)

    Yagyu, Sumio; Maekawa, Koich; Sugawara, Koich; Hayashida, Masaru; Fujishima, Ichiro; Fukuyama, Yuji; Morikawa, Tomoyuki; Yamato, Tadao; Obata, Norio [Advanced Technology Lab., Kubota Corp., Amagasaki, Hyogo (Japan)

    1999-07-01

    This paper describes recent results at Kubota to develop a gas engine driven freon-free heat supply system. Utilizing a gas mixture which consists of CO and H{sub 2} supplied from a broad area energy utilization network, the system produces four heat sources (263 K, 280 K, 318 K, and 353 K) for air-conditioning, hot water supply, and refrigeration in a single system. It also conforms to fuel systems that utilize methane and hydrogen. This multi-functional heat supply system is composed of an efficient gas engine (methanol gas engine) and a freon-free heat pump (heat-assisted Stirling heat pump). The heat-assisted Stirling heat pump is mainly driven by engine shaft power and is partially assisted by thermal power provided by engine exhaust heat. By proportioning the two energy sources to match the characteristics of the driving engine, the heat pump is supplied with the maximum share of the original energy fueling the engine. Developing the system will establish freon-free thermal utilization system technology that satisfies both wide heat demands and various fuel systems. (orig.)

  3. Utilisation of geothermal energy by the municipal works in Neubrandenburg

    International Nuclear Information System (INIS)

    Jahnke, H.

    1994-01-01

    A long distance energy supply plant has been operated on the basis of geothermal energy in Neubrandenburg since September 1988. At present it is still the largest heat generation plant for the utilisation of low thermal pore storage in Germany. The setup and the function of the plant are explained. After the municipal works of Neubrandenburg took over the plant, it was redesigned in order to give a better guarantee for the supply, to improve the economic efficiency and to minimise the environmental impact. At present long distance energy can be provided at a price of 99,00 DM/Mwh for 2000 utilisation hours per year. (BWI) [de

  4. Comparative ecobalancing accounting of semi-central house heat supply from wood residues

    International Nuclear Information System (INIS)

    Biemann, Kirsten

    2015-01-01

    In 2008 almost 40 percent of the German final energy demand was used for room heating and hot water supply. To decrease environmental burdens and to save fossil resources a restructuring of the heating sector is needed. Therefore legislation enforces higher insulation standards of buildings and a more frequent use of renewable energies as well as heating networks. Wood as a renewable and storable energy source is an attractive fuel. However, it must be used as efficiently as possible because of limited wood supplies. Connecting buildings via a heating network is a good option since bigger heating plants can operate at higher efficiencies than small heaters. However, the higher insulation standards of the buildings often oppose the construction of a heating network, because heating networks work best with high energy demands and low network lengths. Therefore the environmental and economic feasibility of new heating networks needs to be checked beforehand. This thesis explores the environmental burdens of different semi- centralized heating networks using wood residues as fuel. A semi- centralized heating network is a network with no more than 500 customers and a heating plant with less than 5 MWth. While wood residues are used in the base load plant, peak load is covered by a gas heating plant. As a method to analyze the potential environmental burdens of the heat supply a life cycle assessment according to ISO 14040/44 is used. Opposed to former life cycle assessment studies, construction and operation of the network is included in the assessment. Even though the environmental impacts of the semi- centralized heating from wood residues are dominated by the heat supply, an observation of the impacts solely at the heating plant is not sufficient. By varying the boundary conditions of the heating network two main contributors to the environmental impacts are found. In addition to the heat production at the plant the type of the buildings in the settlement has a huge

  5. Design of a low temperature district heating network with supply recirculation

    DEFF Research Database (Denmark)

    Li, Hongwei; Dalla Rosa, Alessandro; Svendsen, Svend

    2010-01-01

    The focus on continuing improving building energy efficiency and reducing building energy consumption brings the key impetus for the development of the new generation district heating (DH) system. In the new generation DH network, the supply and return temperature are designed low in order to sig...... calculates the heat loss in the twin pipe as that in the single pipe. The influence of this simplification on the supply/return water temperature prediction was analyzed by solving the coupled differential energy equations.......-pass system starts to function. The aim of this paper is to investigate the influence of by-pass water on the network return temperature and introduce the concept of supply water recirculation into the network design so that the traditional by-pass system can be avoided. Instead of mixing the by-pass water......The focus on continuing improving building energy efficiency and reducing building energy consumption brings the key impetus for the development of the new generation district heating (DH) system. In the new generation DH network, the supply and return temperature are designed low in order...

  6. Biomass Supply Planning for Combined Heat and Power Plants using Stochastic Programming

    DEFF Research Database (Denmark)

    Guericke, Daniela; Blanco, Ignacio; Morales González, Juan Miguel

    method using stochastic optimization to support the biomass supply planning for combined heat and power plants. Our two-phase approach combines mid-term decisions about biomass supply contracts with the short-term decisions regarding the optimal market participation of the producer to ensure......During the last years, the consumption of biomass to produce power and heat has increased due to the new carbon neutral policies. Nowadays, many district heating systems operate their combined heat and power (CHP) plants using different types of biomass instead of fossil fuel, especially to produce......, and heat demand and electricity prices vary drastically during the planning period. Furthermore, the optimal operation of combined heat and power plants has to consider the existing synergies between the power and heating systems while always fulfilling the heat demand of the system. We propose a solution...

  7. Investigation of a low flow solar heating system for space heating and domestic hot water supply for Aidt Miljø A/S

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1997-01-01

    A low flow solar heating system for space heating and domestic hot water supply from Aidt Miljø A/Swas tested in a laboratory test facility.......A low flow solar heating system for space heating and domestic hot water supply from Aidt Miljø A/Swas tested in a laboratory test facility....

  8. Seon heats with geothermal energy

    International Nuclear Information System (INIS)

    Hawkins, A.C.

    2001-01-01

    This article describes the combined use of ground water for the supply of drinking water for the municipality of Seon, Switzerland and as the basis for a district heating system. The use of the water, pumped up from a depth of 300 meters and exhibiting a temperature of 19.5 o C, as the heat source for heat pumps is described. The history of the project is discussed and figures are given on the district heating system that provides heat for an indoor swimming pool complex, industry and living accommodation in the village. Operational strategies used to make optimum use of tariff structures are described. The role played by local initiative in this innovative project is emphasised

  9. Investigation af a solar heating system for space heating and domestic hot water supply with a high degree of coverage

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1999-01-01

    A solar storage tank for space heating and domestic hot water supply was designed and testet in af laboratory test facility.......A solar storage tank for space heating and domestic hot water supply was designed and testet in af laboratory test facility....

  10. Investigation of a solar heating system for space heating and domestic hot water supply for Sol&Træ A.m.b.a

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1999-01-01

    A solar heating system for space heating and domestic hot water supply from "Sol&Træ A.m.b.a." was tested in a laboratory test facility.......A solar heating system for space heating and domestic hot water supply from "Sol&Træ A.m.b.a." was tested in a laboratory test facility....

  11. Gaseous emissions during concurrent combustion of biomass and non-recyclable municipal solid waste

    Directory of Open Access Journals (Sweden)

    Oakey John

    2011-02-01

    Full Text Available Abstract Background Biomass and municipal solid waste offer sustainable sources of energy; for example to meet heat and electricity demand in the form of combined cooling, heat and power. Combustion of biomass has a lesser impact than solid fossil fuels (e.g. coal upon gas pollutant emissions, whilst energy recovery from municipal solid waste is a beneficial component of an integrated, sustainable waste management programme. Concurrent combustion of these fuels using a fluidised bed combustor may be a successful method of overcoming some of the disadvantages of biomass (high fuel supply and distribution costs, combustion characteristics and characteristics of municipal solid waste (heterogeneous content, conflict with materials recycling. It should be considered that combustion of municipal solid waste may be a financially attractive disposal route if a 'gate fee' value exists for accepting waste for combustion, which will reduce the net cost of utilising relatively more expensive biomass fuels. Results Emissions of nitrogen monoxide and sulphur dioxide for combustion of biomass are suppressed after substitution of biomass for municipal solid waste materials as the input fuel mixture. Interactions between these and other pollutants such as hydrogen chloride, nitrous oxide and carbon monoxide indicate complex, competing reactions occur between intermediates of these compounds to determine final resultant emissions. Conclusions Fluidised bed concurrent combustion is an appropriate technique to exploit biomass and municipal solid waste resources, without the use of fossil fuels. The addition of municipal solid waste to biomass combustion has the effect of reducing emissions of some gaseous pollutants.

  12. Thermal Efficiency of Power Module “Boiler with Solar Collectors as Additional Heat Source” For Combined Heat Supply System

    Directory of Open Access Journals (Sweden)

    Denysova A.E.

    2015-04-01

    Full Text Available The purpose of work is to increase the efficiency of the combined heat supply system with solar collectors as additional thermal generators. In order to optimize the parameters of combined heat supply system the mathematical modeling of thermal processes in multi module solar collectors as additional thermal generators for preheating of the water for boiler have been done. The method of calculation of multi-module solar collectors working with forced circulation for various configurations of hydraulic connection of solar collector modules as the new result of our work have been proposed. The results of numerical simulation of thermal efficiency of solar heat source for boiler of combined heat supply system with the account of design features of the circuit; regime parameters of thermal generators that allow establishing rational conditions of its functioning have been worked out. The conditions of functioning that provide required temperature of heat carrier incoming to boiler and value of flow rate at which the slippage of heat carrier is not possible for different hydraulic circuits of solar modules have been established.

  13. Environment-friendly heat supply with natural refrigerants. Large heat pumps use industrial waste heat and waste water; Umweltschonende Waermeversorgung mit natuerlichen Kaeltemitteln. Grosswaermepumpen nutzen industrielle Abwaerme und Abwaesser

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2011-01-15

    Everywhere, where industrial processes occur or coldness is produced, simultaneously heat is produced. While many private houses use geothermal energy or ambient air for the production of heat, waste water and waste heat prove to be optimal energy sources for the industrial need due to higher output temperatures. By means of large heat pumps the residual heat is used for heating or the supply of hot water for example in local heat supply grids and makes an important contribution to climate protection.

  14. Stochastic Programming for Fuel Supply Planning of Combined Heat and Power Plants

    DEFF Research Database (Denmark)

    Guericke, Daniela; Blanco, Ignacio; Morales González, Juan Miguel

    The consumption of biomass to produce power and heat has increased due to the carbon neutral policies. Combined heat and power (CHP) plants often combine biomass with other fuels, e.g., natural gas. The negotiation process for supply contracts involves many uncertainties due to the long planning...... horizon. The demand for biomass is uncertain, and heat demand and electricity prices vary during the planning period. We propose a method using stochastic optimization to support the biomass and natural gas supply planning for CHP plants including short-term decisions for optimal market participation....

  15. Energy concepts for self-supplying communities based on local and renewable energy sources

    DEFF Research Database (Denmark)

    Petersen, Jens-Phillip

    2016-01-01

    The reduction of GHG emissions in buildings is a focus area of national energy policies, because buildings are responsible for a major share of energy consumption. Policies to increase the share of renewable energies and energy efficiency measures are implemented at local scale. Municipalities...... that virtually allow a heating energy and electricity supply fully based on local, renewable energy resources. The most feasible and cost-efficient variant is the use of local food production waste in a CHP plant feeding a district heating grid. The overall aim is to show that a self-sufficient heat......- and electricity supply of typical urban communities is possible and can be implemented in a cost-efficient way, if the energy planning is done systematically and in coherence with urban planning....

  16. SOME FEATURES OF THE POWER SUPPLY OF RESIDENTIAL BUILDINGS DURING THE HEATING SEASON

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2017-01-01

    Full Text Available A large proportion of consumption of different types of energy by the residential sector, especially in the heating period, makes the energy efficiency of buildings without considering the loss of fuel with a significant reduction in hourly load on the generators, especially at night, already insufficient for real energy savings. Therefore in Belarus, in order to attract the consumer, electricity tariff for heating at night hours (from 11 p.m. to 6.00 a.m. is three times cheaper than at any other time. Significant increase of the electricity consumption of at night could be achieved by using heat accumulators for heating and hot water supply to the residential sector. Particularly effective are water accumulators of heat and accumulators of underfloor heating that enable to use a coolant with a temperature of 40 оC and to increase the useful supply of heat. The use of heat accumulators for daily heating, ventilation and hot water supply of buildings significantly reduces the cost of creating the infrastructure of the territory under construction by eliminating the necessity of running the distribution network of heat or gas supply. The use of the heat accumulators is necessary due to the increase of the time-weighted average outdoor temperature. The mentioned increase in the City of Minsk in the heating season is of about 0.1 °C per year in average, and as for the last 20 years, the increase has led to a reduction of the required heat load on the premises by about 10 %. Research and project work on choosing the most effective options for the arrangement and use the heat accumulators in buildings of the various functions ought to be fulfilled in order to make the application of heat accumulators successful. In this respect civil and power engineers as well as operators should work together so to determine the chronological, technical and economic conditions of charging and use of heat accumulators.

  17. Some features of an economical central heating water supply

    International Nuclear Information System (INIS)

    Glaeser, G.

    1990-01-01

    This paper is concerned with the necessary savings of energy and fuel as well as reduction of pollutant emission in the field of central district heat supply. Results of studies on solving these problems are presented. To provide thermal power based on heating water essential features of the district heating system in the GDR are outlined and advantages, resources and limits of specific solutions quantified. Finally, selected systems are evaluated as to energy and cost expenses, and some conclusions are drawn for future concepts. (author)

  18. National conference on centralized heat supply from heat feeders in selected localities

    International Nuclear Information System (INIS)

    1990-05-01

    The proceedings contain 8 contributions, out of which 5 have been inputted in INIS. These deal with centralized heat supply systems, hydraulic and thermal parameters of the hot water distribution systems, and the feasibility of including nuclear sources into the systems. Treated are both actual systems and calculation models. (B.S.)

  19. Increased system benefit from cogeneration due to cooperation between district heating utility and industry

    Energy Technology Data Exchange (ETDEWEB)

    Danestig, M.; Henning, D. [Division of Energy Systems, Department of Mechanical Engineering, Linkoping Institute of Technology, Linkoping (Sweden)

    2004-07-01

    District heating and steam supply in the town Oernskoeldsvik in northern Sweden is in focus for this study. Low temperature waste heat from pulp manufacturing in the Donisjoe mill is now utilised for district heating production in heat pumps, which dominate district heating supply. Based on this traditional cooperation between the local district heating utility and the pulp industry, the parties discuss a partial outsourcing of the industrial steam supply to the utility, which may enable beneficial system solutions for both actors. The local utility must find a new location for a heating plant because a railway line is being built at the heat pump site. Planning for a new combined heat and power production (CHP) plant has started but its location is uncertain. If the plant can be situated close to the mill it can, besides district heating, produce steam, which can be supplied to adjacent industries. The municipality and its local utility are also considering investing in a waste incineration plant. But is waste incineration suitable for Ornskoeldsvik and how would it interact with cogeneration. Alternative cases have been evaluated with the MODEST energy system optimisation model, which minimises the cost for satisfying district heating and steam demand. The most profitable solution is to invest in a CHP plant and a waste incineration plant. Considering carbon dioxide emissions, the results from applying a local or a global perspective are remarkably different. In the latter case, generated electricity is assumed to replace power from coal condensing plants elsewhere in the North-European power grid. Therefore, minimum global CO{sub 2} emissions are achieved through maximal electricity production in a CHP plant. From this viewpoint, waste incineration should not be introduced because it would obstruct cogeneration. The study is carried out within the program Sustainable municipality run by the Swedish Energy Agency. (orig.)

  20. EFFECTIVENESS ANALYSIS OF CAMPUS HEAT SUPPLY SYSTEM OF DNIPROPETROVSK NATIONAL UNIVERSITY OF RAILWAY TRANSPORT

    Directory of Open Access Journals (Sweden)

    O. M. Pshinko

    2014-03-01

    Full Text Available Purpose. Heat consumption for heating and hot water supply of housing and industrial facilities is an essential part of heat energy consumption. Prerequisite for development of energy saving measures in existing heating systems is their preliminary examination. The investigation results of campus heating system of Dnipropetrovsk National University of Railway Transport named after Academician V. Lazaryan are presented in the article. On the basis of the analysis it is proposed to take the energy saving measures and assess their effectiveness. Methodology. Analysis of the consumption structure of thermal energy for heating domestic and hot water supply was fulfilled. The real costs of heat supply during the calendar year and the normative costs were compared. Findings. The recording expenditures data of thermal energy for heating supply of residential buildings and dormitories in 2012 were analyzed. The comparison of actual performance with specific regulations was performed. This comparison revealed problems, whose solution will help the efficient use of thermal energy. Originality. For the first time the impact of climate conditions, features of schemes and designs of heating systems on the effective use of thermal energy were analyzed. It was studied the contribution of each component. Practical value. Based on the analysis of thermal energy consumption it was developed a list of possible energy saving measures that can be implemented in the system of heat and power facilities. It was evaluated the fuel and energy resources saving.

  1. Nitrogen Gas Heating and Supply System for SST-1 Tokamak

    International Nuclear Information System (INIS)

    Khan, Ziauddin; Pathan, Firozkhan; Paravastu, Yuvakiran; George, Siju; Ramesh, Gattu; Bindu, Hima; Raval, Dilip C.; Thankey, Prashant; Dhanani, Kalpesh; Pradhan, Subrata

    2013-01-01

    Steady State Tokamak (SST-1) vacuum vessel baking as well as baking of the first wall components of SST-1 are essential to plasma physics experiments. Under a refurbishment spectrum of SST-1, the nitrogen gas heating and supply system has been fully refurbished. The SST-1 vacuum vessel consists of ultra-high vacuum (UHV) compatible eight modules and eight sectors. Rectangular baking channels are embedded on each of them. Similarly, the SST-1 plasma facing components (PFC) are comprised of modular graphite diverters and movable graphite based limiters. The nitrogen gas heating and supply system would bake the plasma facing components at 350°C and the SST-1 vacuum vessel at 150°C over an extended duration so as to remove water vapour and other absorbed gases. An efficient PLC based baking facility has been developed and implemented for monitoring and control purposes. This paper presents functional and operational aspects of a SST-1 nitrogen gas heating and supply system. Some of the experimental results obtained during the baking of SST-1 vacuum modules and sectors are also presented here. (fusion engineering)

  2. Conceptual adsorption system of cooling and heating supplied by solar energy

    Directory of Open Access Journals (Sweden)

    Turski Michał

    2016-06-01

    Full Text Available This paper presents the possibility of reducing the demand for nonrenewable primary energy for buildings using a new conceptual adsorption system of cooling and heating supplied by solar energy. Moreover, the aim of this study is to shorten the payback time of investment in the standard adsorption cooling system through its integration with the heating system. Research has been carried out for an energy-efficient medium-sized single-family building with a floor area of 140 m2 and a heat load of 4.2 kW and cold load of 4.41 kW. It has been shown that the use of an adsorption system of cooling and heating supplied by solar energy decreased the demand for nonrenewable primary energy by about 66% compared to the standard building that meets the current requirements.

  3. Master plan study - District heating Kohtla-Jaerve and Johvi municipalities. Estonia. Final report. Appendices for chapter 7

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The appendices to chapter 7 of the master plan study on district heating in the municipalities of Kohtla-Jarve and Johvi (Estonia) present technical data on production units, also with regard to new facilities. (ARW)

  4. Loop heat pipes - highly efficient heat-transfer devices for systems of sun heat supply

    Energy Technology Data Exchange (ETDEWEB)

    Maydanik, Yu. [Ural Branch of the Russian Academy of Sciences, Ekaterinburg (Russian Federation). Inst. of Thermophysics

    2004-07-01

    Loop heat pipes (LHPs) are hermetic heat-transfer devices operating on a closed evaporation-condensation cycle with the use of capillary pressure for pumping the working fluid [1]. In accordance with this, they possess all the main advantages of conventional heat pipes, but, as distinct from the latter, have a considerably higher heat-transfer capacity, especially when operating in the ''antigravity'' regime, when heat is transferred from above downwards. Besides, LHPs possess a higher functional versatility, are adaptable to different operating conditions and provide great scope for various design embodiments. This is achieved at the expense of both the original design of the device and the properties of the wick - a special capillary structure used for the creation of capillary pressure. The LHP schematic diagram is given in Fig. 1. The device contains an evaporator and a condenser - heat exchanger connected by means of smooth-walled pipe-lines with a relatively small diameter intended for separate motion of vapor and liquid. At present loop heat pipes are most extensively employed in thermoregulation systems of spacecrafts. Miniature LHPs are used for cooling electronics and computers. At the same time there exists a considerable potential of using these devices for the recovery of low-grade (waste) heat from different sources, and also in systems of sun heat supply. In the latter case LHPs may serve as an efficient heat-transfer link between a sun collector and a heat accumulator, which has a low thermal resistance and does not consume any additional energy for pumping the working fluid between them. (orig.)

  5. Renewable municipal waste barometer

    International Nuclear Information System (INIS)

    2014-01-01

    In the European Union the production of primary energy from the incineration of municipal waste increased by only 0.7% in 2013 and reached 8.7 million tep (tonnes of oil equivalent). Germany ranks first with the production of 2729 ktep followed by France with 1246 ktep. A positive point is that the sale of heat to heat networks has strongly increased in some countries which means that primary energy is better used. 2 tables give the production of electricity and heat from the incineration of municipal waste in the E.U. member states in 2012 and 2013. Germany ranks first in the 2 tables. The total production of electricity and heat from the incineration of municipal waste in E.U. in 2013 reached 18741 GWh and 2361 tep respectively. A list reviews the most significant companies working in Europe in the sector of waste incineration, 8 companies are listed, 2 are German: EEW, Remondis, 3 are French: SITA (Suez Environment, Veolia and TIRU (EDF), Urbaser is spanish, Gruppo Hera is Italian and AEB-Amsterdan is dutch. (A.C.)

  6. Local energy supply under national and European law. With special regard to municipal policy opportunities. Oertliche Energieversorgung nach nationalem und europaeischem Recht. Unter besonderer Beruecksichtigung kommunaler Gestaltungsmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Britz, G.

    1994-01-01

    Conceivably, the erection of a single European energy market for electricity and natural gas as specified in the EC draft guidelines may change the conditions of local energy supply. This thesis therefore investigates which instruments are at the disposal of municipal governments for the realization of energy-political concepts of their own: Rights of way and granting of franchises, establishment of and transfer of tasks to municipal utilities, common carvier duties, and free choice of suppliers by distributors. The handling of franchise payments and treatment of municipal interconnected networks are of considerable importance for the financial situation of communities. The first section deals with the legal issues of local energy supply with regard to national law. The second part deals with the same questions with regard to community law. Furthermore it is considered what would be the consequences of the realization of the two guidelines concerning the single energy market. In the final section the results are compared and the significance of community law for local energy supply is assessed. (orig./HP)

  7. Current and future prospects for heat recovery from waste in European district heating systems: A literature and data review

    International Nuclear Information System (INIS)

    Persson, Urban; Münster, Marie

    2016-01-01

    Municipal solid waste has seen increasing annual volumes for many decades in contemporary Europe and constitutes, if not properly managed, an environmental problem due to local pollution and greenhouse gas emissions. From an energy perspective, waste is also an alternative fuel for power and heat generation; energy recovery from waste represents an effective measure to reduce landfilling and avoid disposal emissions while simultaneously reducing the equivalent demand for primary energy supply. A key factor for obtaining the full synergetic benefits of this energy recovery is the presence of local heat distribution infrastructures, without which no large-scale recovery and utilisation of excess heat is possible. In this paper, which aims to estimate municipal solid waste volumes available for heat recovery in European district heating systems in 2030, a literature and data review is performed to establish and assess current and future EU (European Union) waste generation and management. Main conclusions are that more heat can be recovered from current Waste-to-Energy facilities operating at low average heat recovery efficiencies, that efficient incineration capacity is geographically concentrated, and that waste available for heat recovery in 2030 is equally determined by total generation volumes by this year as by future EU deployment levels of district heating. - Highlights: • European municipal solid waste time series data analysed from 1995 to 2012. • Review of modelling approaches to assess future European waste generation. • Weather corrected district heat data for EU Member States in 1995 and 2012. • Low average heat recovery efficiency in current European waste incineration. • Future heat recovery efficiencies as determinant as future generation volumes.

  8. Development of an innovative low temperature heat supply concept for a new housing area

    OpenAIRE

    Schmidt, Dietrich; Kallert, Anna; Orozaliev, Janybek; Best, Isabelle; Vajen, Klaus; Reul, Oliver; Bennewitz, Jochen; Gerhold, Petra

    2017-01-01

    The domestic energy demand of buildings is responsible for one third of the world's final energy consumption. To increase the sustainability of new housing areas, the identification of innovative heat supply concepts based on renewable energy sources (RES) is required. For the new housing area “Zum Feldlager” (Kassel, Germany), various supply concepts are studied. Main objective is the development of an innovative and efficient supply concept based on RES and low temperature district heating ...

  9. Investigation of a heat storage for a solar heating system for combined space heating and domestic hot water supply for homeowner´s association "Bakken"

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1998-01-01

    A heat storage for a solar heating system for combined space heating and domestic hot water supply was tested in a laboratory test facility.The heat storage consist of a mantle tank with water for the heating system and of a hot water tank, which by means of thermosyphoning is heated by the water...

  10. Experimental evaluation of radiator control based on primary supply temperature for district heating substations

    International Nuclear Information System (INIS)

    Gustafsson, Jonas; Delsing, Jerker; Deventer, Jan van

    2011-01-01

    Highlights: → We compared a new radiator system control approach with traditional control. → This is an experimental verification of previous simulation results. → We examine changes in delta-T and indoor comfort. → The indoor comfort were not affected by the introduction of alt. radiator control. → The alternative control method can contribute to an increased delta-T. -- Abstract: In this paper, we evaluate whether the primary supply temperature in district heating networks can be used to control radiator systems in buildings connected to district heating; with the purpose of increasing the ΔT. The primary supply temperature in district heating systems can mostly be described as a function of outdoor temperature; similarly, the radiator supply temperature in houses, offices and industries can also be described as a function of outdoor temperature. To calibrate the radiator control system to produce an ideally optimal radiator supply temperature that produces a maximized ΔT across the substation, the relationship between the primary supply temperature and outdoor temperature must be known. However, even if the relation is known there is always a deviation between the expected primary supply temperature and the actual temperature of the received distribution media. This deviation makes the radiator control system incapable of controlling the radiator supply temperature to a point that would generate a maximized ΔT. Published simulation results show that it is possible and advantageous to utilize the primary supply temperature for radiator system control. In this paper, the simulation results are experimentally verified through implementation of the control method in a real district heating substation. The primary supply temperature is measured by the heat-meter and is shared with the radiator control system; thus no additional temperature sensors were needed to perform the experiments. However additional meters were installed for surveillance purposes

  11. Method for reducing excess heat supply experienced in typical Chinese district heating systems by achieving hydraulic balance and improving indoor air temperature control at the building level

    DEFF Research Database (Denmark)

    Zhang, Lipeng; Gudmundsson, Oddgeir; Thorsen, Jan Eric

    2016-01-01

    A common problem with Chinese district heating systems is that they supply more heat than the actual heat demand. The reason for this excess heat supply is the general failure to use control devices to adjust the indoor temperature and flow in the building heating systems in accordance with the a......A common problem with Chinese district heating systems is that they supply more heat than the actual heat demand. The reason for this excess heat supply is the general failure to use control devices to adjust the indoor temperature and flow in the building heating systems in accordance...... with the actual heat demand. This results in 15-30% of the total supplied heat being lost. This paper proposes an integrated approach that aims to reduce the excess heat loss by introducing pre-set thermostatic radiator valves combined with automatic balancing valves. Those devices establish hydraulic balance...... that once the hydraulic balance is achieved and indoor temperatures are controlled with this integrated approach, 17% heat savings and 42.8% pump electricity savings can be achieved. The energy savings will also have a positive environmental effect with seasonal reductions of 11 kg CO2, 0.1 kg SO2, and 0...

  12. Solar heating and hot water system installed at Municipal Building complex, Abbeville, South Carolina

    Science.gov (United States)

    1979-01-01

    Information on the solar energy system installed at the new municipal building for the City of Abbeville, SC is presented, including a description of solar energy system and buildings, lessons learned, and recommendations. The solar space heating system is a direct air heating system. The flat roof collector panel was sized to provide 75% of the heating requirement based on an average day in January. The collectors used are job-built with two layers of filon corrugated fiberglass FRP panels cross lapped make up the cover. The storage consists of a pit filled with washed 3/4 in - 1 1/2 in diameter crushed granite stone. The air handler includes the air handling mechanism, motorized dampers, air circulating blower, sensors, control relays and mode control unit. Solar heating of water is provided only those times when the hot air in the collector is exhausted to the outside.

  13. Analysis of an effective solution to excessive heat supply in a city primary heating network using gas-fired boilers for peak-load compensation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hai-Chao; Jiao, Wen-Ling; Zou, Ping-Hua; Liu, Jing-Cheng [School of Municipal and Environmental Engineering, Harbin Institute of Technology, mail box 2645, 202 Haihe Road, Nangang District, Harbin 150090 (China)

    2010-11-15

    Through investigation of the Dengfeng heating network in the city of Daqing, China, for the 2007-2008 heating season, we found serious problems of excessive heat supply in the primary heating network. Therefore, we propose the application of gas-fired boilers in underperforming heating substations as peak-load heat sources to effectively adapt to the regulation demands of seasonal heat-load fluctuations and reduce the excessive heat supply. First, we calculated the excessive heat supply rates (EHSRs) of five substations using detailed investigative data. We then discussed the feasibility of the proposed scheme providing energy savings from both energetic and exergetic points of view. The results showed that the average EHSR of the five substations between January and March was 20.57% of the gross heat production but consequently reduced to 6.24% with the installation of the gas-fired boilers. Therefore, the combined heating scheme with coal as the basic heat-source and gas-fired boilers as peak-load heat sources is energy-efficient to some extent, although requires the use of natural gas. Meanwhile, the exergy decreased by 10.97%, which indicates that the combined heating scheme effectively reduces the primary energy consumption and pollutant emission of the heating systems. (author)

  14. Hybrid renewable energy system application for electricity and heat supply of a residential building

    Directory of Open Access Journals (Sweden)

    Nakomčić-Smaragdakis Branka B.

    2016-01-01

    Full Text Available Renewable and distributed energy systems could provide a solution to the burning issue of reliable and clean supply of energy, having in mind current state and future predictions for population growth and fossil fuel scarcity. Hybrid renewable energy systems are novelty in Serbia and warrant further detailed research. The aim of this paper is to analyze the application of renewable energy sources(RES for electricity and heat supply of a typical household in Serbia, as well as the cost-effectiveness of the proposed system. The influence of feed-in tariff change on the value of the investment is analyzed. Small, grid-connected hybrid system (for energy supply of a standard household, consisting of geothermal heat pump for heating/cooling, solar photovoltaic panels and small wind turbine for power supply is analyzed as a case study. System analysis was conducted with the help of RETScreen software. Results of techno-economics analysis have shown that investing in geothermal heat pump and photovoltaic panels is cost-effective, while that is not the case with small wind turbine.

  15. Development of hot water supply system for a small district heating reactor

    International Nuclear Information System (INIS)

    Murase, Toshihiko; Narabayashi, Tadashi; Shimazu, Yoichiro

    2007-01-01

    On the earth, there are many environmental problems. For example, rapid increase of world population causes the enormous consumption of fossil fuel and emission of CO 2 into the global air. Now, mankaind faced to deal with these serious problems. One solution for these problems is utilization of nuclear reactors. Currently, about 65% of thermal output of a nuclear reactor is thrown away to the sea or the atmosphere through a turbine condenser. When a hot-water pipeline from a nuclear plant will be constructed, the exhaust heat from nuclear reactor will able to be utilized. Therefore, authors began to study nuclear power plant system for district heating. This reactor is based on a PWR plant. Its thermal output is 10 MWth and its electrical output is 3.4 MW. The nuclear plant supply electricity and heat for 2000 to 3000 houses. The plant aim to supply all the energy for the adjacent pepole's life, for example, heat, electricity and hydrogen for fuel battery car. This total-energy supply system assumed to be built in Northern area such as Hokkaido in Japan. In order to develop an optimum thermal design method for the system, heat transport experiments and thermal-hydraulic calculations were carried out. Using a metal pipe covered with foam-polyurethane thermal insulator, feed-water temperature and return-water temperature was measured to evaluate heat loss. As the result, the heat loss from the hot-water temperature was very little. The thermal-hydraulic calculation method was verified and applied to actual pipeline size calculation. The result of heat loss calculation will be 0.2degC/5 km. considering these results, the best pipe specification was obtained. (author)

  16. Radiation hygienic assessment of centralized heat and hot water supply of Bilibino village from Bilibin central nuclear heating- and power plant

    International Nuclear Information System (INIS)

    Eremin, V.A.; Marej, A.N.; Nechiporenko, N.I.; Rasskazov, A.P.; Sayapin, N.P.; Soldatov, G.E.; Shcherbinin, A.S.

    1983-01-01

    The experience in using an atomic power plant for heat and hot water supply of the village of Bilibino is outlined. Particular attention is given to the population radiation safety. It has been demonstrated that radiation safety of the system is ensured by maintaining fixed pressure levels in the heating media and by the hermetic state of heat exchanges. Water in the heat and hot water supply network meets the requirements for drinking water. Radioactive corrosion products were not detected in the test water. Gamma-radiation dose rate from the surface of heating devices and pipe-lines in the test premises did not exceed the natural background, that is, U.U1-0.025 mrad

  17. SECURE nuclear district heating plant

    International Nuclear Information System (INIS)

    Nilsson; Hannus, M.

    1978-01-01

    The role foreseen for the SECURE (Safe Environmentally Clean Urban REactor) nuclear district heating plant is to provide the baseload heating needs of primarily the larger and medium size urban centers that are outside the range of waste heat supply from conventional nuclear power stations. The rationale of the SECURE concept is that the simplicity in design and the inherent safety advantages due to the use of low temperatures and pressures should make such reactors economically feasible in much smaller unit sizes than nuclear power reactors and should make their urban location possible. It is felt that the present design should be safe enough to make urban underground location possible without restriction according to any criteria based on actual risk evaluation. From the environmental point of view, this is a municipal heat supply plant with negligible pollution. Waste heat is negligible, gaseous radioactivity release is negligible, and there is no liquid radwaste release. Economic comparisons show that the SECURE plant is competitive with current fossil-fueled alternatives. Expected future increase in energy raw material prices will lead to additional energy cost advantages to the SECURE plant

  18. Indicators System Creation For The Energy Efficiency Benchmarking Of Municipal Power System Facilities

    Directory of Open Access Journals (Sweden)

    Davydenko L.V.

    2015-04-01

    Full Text Available The issues of the dataware of the comparative analysis procedure (benchmarking for municipal power system facilities energy efficiency level estimation with a view of the hierarchical structure of the heat supply system are considered. The aim of the paper is the system of indicators formation for characterizing the efficiency of energy usage as on objects on lowest so on highest levels of power systems, proceeding from features of their functioning. Benchmarking methodology allows carrying out the estimation of energy efficiency level on the base of a plurality of parameters without their generalization in one indicator, but requires ensuring their comparability. Using the methodology of available statistical information that did not require deep specification and additional inspection structuring objectives and tasks of energy efficiency estimation problem has been proposed for ensuring the opportunity of benchmarking procedure implementation. This makes it possible to form the subset of indicators that ensure enough specification of the object of study, taking into account the degree of abstraction for every hierarchical level or sub problem. For a comparative analysis of energy using efficiency in municipal power systems at the highest levels of the hierarchy a plurality of indicators of the energy efficiency has been formed. Indicators have been determined with consideration of the structural elements of heat supply systems, but allowing taking into account the efficiency of the initial state of the objects, their functioning, and the questions of energy resources accounting organization. Usage of the proposed indicators provides implementation of energy using efficiency monitoring in the municipal power system and allows getting complete overview of the problem.

  19. Development of objectives for the business operations and real estate management of the municipalities. Kuntien liikelaitostoimintojen ja kiinteistoenhoidon tavoitteellinen kehittaeminen

    Energy Technology Data Exchange (ETDEWEB)

    Kalliomaeki, M [Suomen Kunnallisliitto, Helsinki (Finland)

    1987-01-01

    In 1986 a research project was started dealing with the development of district heating, water supply and sewerage operations and real estate management of the municipalities. It was carried out as a test operation project in three municipalities: Asikkala, Hollola and Laukaa. It aimed at bringing about resources for a continuous development of the operations. The project ended formally by planning objectives for the year 1988. The development work in the test municipalities goes on. An all-inclusive method of development was applied in the project with the objective to combine theory and practice. The purpose was to find practical means of improving the profitability of the municipalities' district heating operations and real estate management under the prevailing conditions. The form of organisation or the accounting systems were not as such objects for the research but it was found that these do affect the profitability of operations, i.a. through the clarity of motivation and clarity of questions to do with responsibility and authority. According to the research, the applied contents- and profit-oriented control of operations improves the preconditions profitable municipal district heating operations and real estate management. However, the present means of control (planning, accounting and follow-up systems) used in the municipal administrations support an input-oriented type of leadership. For this reason, those rules which control i.a. the staff administration, planning practices, profit follow-up practices, accounting systems and the utilisation and functions of data technology should be developed to support a profit-oriented type of control.

  20. Some Problems of the Integration of Heat Pump Technology into a System of Combined Heat and Electricity Production

    Directory of Open Access Journals (Sweden)

    G. Böszörményi

    2001-01-01

    Full Text Available The closure of a part of the municipal combined heat and power (CHP plant of Košice city would result in the loss of 200 MW thermal output within a realtively short period of time. The long term development plan for the Košice district heating system concentrates on solving this problem. Taking into account the extremely high (90 % dependence of Slovakia on imported energy sources and the desirability of reducing the emission of pollutantst the alternative of supplying of 100 MW thermal output from geothermal sources is attractive. However the indices of economic efficiency for this alternative are unsatisfactory. Cogeneration of electricity and heat in a CHP plant, the most efficient way of supplying heat to Košice at the present time. If as planned, geothermal heat is fed directly into the district heating network the efficiency would be greatly reduced. An excellent solution of this problem would be a new conception, preferring the utilization of geothermal heat in support of a combined electricity and heat production process. The efficiency of geothermal energy utilization could be increased through a special heat pump. This paper deals with several aspects of the design of a heat pump to be integrated into the system of the CHP plant.

  1. Various methods of heat supply for a building which is operated periodically during the year

    Science.gov (United States)

    Małetka, Marek; Laska, Marta

    2017-11-01

    Stand-alone buildings operated periodically require heat supply for hot water and heating purposes to be carefully analyzed in terms of the technical capabilities, the energy and financial outlays. The paper presents the analysis of heat supply for hot water purposes and central heating in the stand-alone cloakroom building located in Poland. The analysis is undertaken for different variants of heat delivery for a building from electric heaters, gas boiler and district heating solutions to renewable sources applications, namely solar panels and heat pumps. For each solution, usage of usable, final and primary energy was calculated. Also the financial analysis for investments and energy costs were carried out. This analysis has been done in according to SPBT and NPV method for different levels of building use.

  2. Dual-purpose LWR supplying heat for desalination

    International Nuclear Information System (INIS)

    Waplington, G.; Fitcher, H.

    1977-01-01

    A number of desalination processes are at present in various stages of development but distillation is the only serious choice for a large-scale project. The distillation process temperature requirement is low compared with the temperature of steam normally delivered to the turbine in a power generation plant. This gives the possibility for combining the functions of electricity generation with water distillation. The brine heater of the multi-stage flash distillation plant can be supplied with steam after partial expansion through a turbine. Such an arrangement allows the use of a standard nuclear steam supply system and makes fuller use of the energy output than would either single purpose role. The LWR represents a safe, reliable and economic system, and is easily able to provide heat of a quality adequate for the desalination process. (M.S.)

  3. ANÁLISIS DE LA CADENA DE VALOR HORTOFRUTÍCOLA DEL MUNICIPIO MARIANAO EN LA HABANA, CUBA / FRUITS AND VEGETABLES SUPPLY CHAIN ANALYSIS IN MARIANAO MUNICIPALITY AT HAVANA, CUBA

    Directory of Open Access Journals (Sweden)

    José Antonio Acevedo-Suárez

    2012-04-01

    Full Text Available En Cuba, el funcionamiento de las redes hortofrutícolas se rigen por la estructura del Ministerio de la Agricultura denominada Operación Producción-Acopio-Comercialización, que va desde un Puesto de Dirección Nacional hasta los municipales. De manera que, de la semilla al plato, las futas y vegetales fluyen por redes que reflejan su eficiencia en la disponibilidad en los mercados municipales. El objetivo general que plantea este estudio es analizar la estructura y funcionamiento de la cadena de valor hortofrutícola del municipio Marianao en La Habana, Cuba. La investigación abordará la identificación de eslabones y actores de esta cadena, la evaluación con los Modelos de Referencia de la Logística y Red de Valor y un análisis causa-efecto de los problemas de esta red. El resultado permite identificar la problemática municipal para proponer estrategias de mejoramiento en función de los elementos de las redes de valor.AbstractIn Cuba, the fruits and vegetables supply chain works with the structure established by the Ministry of Agriculture, named Production-Distribution-Sale Operation, which includes national directions to municipal management. So from the plant to the plate, fruits and vegetables flow through chains that reflect their efficiency on the availability in municipality markets. The general objective of this study is to analyze the structure and operation of the fruits and vegetables supply chain in Marianao municipality at Havana, Cuba. This investigation deals with the identification of the different links and members of this supply chain, its evaluation based on the Reference Models of Logistic and Value Chain and a cause-effect analysis about the problems in the above mentioned chain. The results permit to identify the problems of this municipality and to propose strategies in order to improve the situation, based on the elements of the supply chain.

  4. Advanced marine reactor MRX and application to nuclear barge supplying electricity and heat

    International Nuclear Information System (INIS)

    Ishida, Toshihisa; Kusunoki, Tsuyoshi; Odano, Naoteru; Yoritsune, Tsutomu; Fukuhara, Yoshifumi; Ochiai, Masa-aki

    2000-01-01

    The basic design concept of an advanced marine reactor MRX has been established with adoption of several new technologies. The MRX is an integral-type PWR with 100 MWt aimed basically for use of ship propulsion. Adoption of a water-filled containment together with the integral type reactor makes the reactor light-weight and compact greatly. A engineered safety system is a simplified passive system, function of which is confirmed by the safety analysis. The MRX can be applied to an energy supply system of electricity and heat co-generation by installing it on a barge. Concept of a nuclear barge with the MRX of 334 MWt output is presented for use of supplying electricity, fresh water and hot water. Combined system of electric generation and desalination with the RO process can deliver variable output of electricity and fresh water according a demand. Latent heat of the exhausted steam from the turbine can be used effectively to raise the temperature of cold water as heat supply. (author)

  5. Various methods of heat supply for a building which is operated periodically during the year

    Directory of Open Access Journals (Sweden)

    Małetka Marek

    2017-01-01

    Full Text Available Stand-alone buildings operated periodically require heat supply for hot water and heating purposes to be carefully analyzed in terms of the technical capabilities, the energy and financial outlays. The paper presents the analysis of heat supply for hot water purposes and central heating in the stand-alone cloakroom building located in Poland. The analysis is undertaken for different variants of heat delivery for a building from electric heaters, gas boiler and district heating solutions to renewable sources applications, namely solar panels and heat pumps. For each solution, usage of usable, final and primary energy was calculated. Also the financial analysis for investments and energy costs were carried out. This analysis has been done in according to SPBT and NPV method for different levels of building use.

  6. Feasibility study on rehabilitation and improvement of thermal power plants, district heating and heat supply system in Botosani City

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Discussions have been given on the improvement and modification project intended of saving energies and reducing greenhouse gas emission in the Botosani district heating and heat supplying facilities in Romania. Thirty years have elapsed since the building of the Botosani district heating and heat supplying facilities, whereas noticeable energy loss has occurred due to aged deterioration, such as thermal efficiency decrease, performance decrease, and hot water leakage due to piping corrosion. The present project is intended to improve the heat production and power generation facility efficiencies, and reduce the heat loss in heat transportation and distribution to less than 5%. The improvements will be implemented by replacing and rehabilitating the existing boilers, replacing the turbine generators, and replacing the transportation and distribution pipelines and heat exchangers. As a result of the discussions, the present project is estimated to result in annual fuel conservation of 35,820 tons of crude oil equivalent, and annual reduction of the greenhouse gas emission of 110,835 t-CO2. The total amount of the initial investment for the project would be 11.369 billion yen, and the payback period would be 12 years. The project will produce profit of 31.358 billion yen in 20 years, thus the project is financially feasible. (NEDO)

  7. Identifying the optimal supply temperature in district heating networks - A modelling approach

    DEFF Research Database (Denmark)

    Mohammadi, Soma; Bojesen, Carsten

    2014-01-01

    of this study is to develop a model for thermo-hydraulic calculation of low temperature DH system. The modelling is performed with emphasis on transient heat transfer in pipe networks. The pseudo-dynamic approach is adopted to model the District Heating Network [DHN] behaviour which estimates the temperature...... dynamically while the flow and pressure are calculated on the basis of steady state conditions. The implicit finite element method is applied to simulate the transient temperature behaviour in the network. Pipe network heat losses, pressure drop in the network and return temperature to the plant...... are calculated in the developed model. The model will serve eventually as a basis to find out the optimal supply temperature in an existing DHN in later work. The modelling results are used as decision support for existing DHN; proposing possible modifications to operate at optimal supply temperature....

  8. Modelling and multi-scenario analysis for electric heat tracing system combined with low temperature district heating for domestic hot water supply

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    Low temperature district heating (LTDH) is a cost-efficient way of supplying space heating and domestic hot water (DHW) for buildings in urban areas. However, there is concern that the potential hygiene problems (Legionella) might occur if LTDH is implemented, especially for large buildings...... performance on heat loss saving, and it also gave benefits to district heating network by sharing part of the heating load....

  9. Supply of fossil heating and motor fuels

    International Nuclear Information System (INIS)

    Kaegi, W.; Siegrist, S.; Schaefli, M.; Eichenberger, U.

    2003-01-01

    This comprehensive study made for the Swiss Federal Office of Energy (SFOE) within the framework of the Energy Economics Fundamentals research programme examines if it can be guaranteed that Swiss industry can be supplied with fossil fuels for heating and transport purposes over the next few decades. The results of a comprehensive survey of literature on the subject are presented, with a major focus being placed on oil. The study examines both pessimistic and optimistic views and also presents an overview of fossil energy carriers and the possibilities of substituting them. Scenarios and prognoses on the availability of fossil fuels and their reserves for the future are presented. Also, new technologies for exploration and the extraction of fossil fuels are discussed, as are international interdependencies that influence supply. Market and price scenarios are presented that take account of a possible increasing scarcity of fossil fuels. The implications for industry and investment planning are examined

  10. Reduced heat stress in offices in the tropics using solar powered drying of the supply air

    DEFF Research Database (Denmark)

    Gunnarsen, Lars; Santos, A M B

    2002-01-01

    air may facilitate personal cooling by increased evaporation of sweat. Heat acclimatized people with efficient sweating may in particular benefit from this cooling. A prototype solar powered supply system for dried-only air was made. Air from the system was mixed with room air, heated to six different...... content of room air, temperature of supply air and moisture content of supply air was developed based on the experiments. Reduction of moisture content in the supply air by 1.6 g/kg had the same effect as lowering the operative temperature by 1 degree C. The solar-powered system for supplying dry air...... is a low-cost alternative to traditional air conditioning in hot and humid regions....

  11. Optimized district heating supply temperature for large networks; Optimerad framledningstemperatur foer stora fjaerrvaermenaet

    Energy Technology Data Exchange (ETDEWEB)

    Saarinen, Lisa; Boman, Katarina

    2012-02-15

    The supply temperature of the Uppsala district heating network was optimized using a model-based control strategy. Simulation of the network showed that the supply temperature could be decreased by in average 8 deg and the electricity production of the plants supplying the network could be increased with 2.5 % during the period January- April, giving an extra income of 1.2 MSEK due to increased income from electricity sales

  12. Heat production thanks to waste water; Produire de l'energie grace aux eaux usees

    Energy Technology Data Exchange (ETDEWEB)

    Wellstein, J.

    2009-07-01

    The district heating of a large residential compound in Rheinfelden, Switzerland has been refurbished and extended in order to include new buildings and take advantage of the heat from the municipal waste water treatment plant. The initial system was built in 1976 and delivered heat to 3000 people in 1050 housing units, from three natural gas fired boilers with a total power of 3 MW. In 1993, a study supported by the Swiss Federal Office of Energy identified considerable possible energy savings. Some operational measures were implemented immediately. The recent extension of the district heating to a second residential compound in the neighbourhood increased the heat demand by about 50%. In the course of the planning process it was recognized that waste water from the joint municipal treatment plant of Rheinfelden and Magden - a second city located in the vicinity - has to be cooled by 5 K before being rejected into the Rhine River. This water is now used after filtration as the heat source for two big heat pumps (total 2.5 MW; working fluid: ammonia) supplying the refurbished and extended district heating. Peak heat demand is covered by natural gas boilers (total 9 MW) that can operate alone or in parallel with the heat pumps. Provision has been made to later connect another waste heat source to the district heating network: the municipal skating rink and swimming pool sport facility.

  13. Prospects for jointly using solar and wind energy for heat supply and hot water supply to private houses under the conditions of Baku

    International Nuclear Information System (INIS)

    Salamov, O. M.; Aliev, F. F.

    2013-01-01

    This paper analyzes the discovery of the potential for jointly using solar and wind energy for heat supply (HS) and hot water supply (HWS) to a one-family private house located in the Apsheron Peninsula. (authors)

  14. Reuse of waste water: impact on water supply planning

    Energy Technology Data Exchange (ETDEWEB)

    Mangan, G.F. Jr.

    1978-06-01

    As the urban population of the world increases and demands on easily developable water supplies are exceeded, cities have recourse to a range of management alternatives to balance municipal water supply and demand. These alternatives range from doing nothing to modifying either the supply or the demand variable in the supply-demand relationship. The reuse or recycling of urban waste water in many circumstances may be an economically attractive and effective management strategy for extending existing supplies of developed water, for providing additional water where no developable supplies exist and for meeting water quality effluent discharge standards. The relationship among municipal, industrial and agricultural water use and the treatment links which may be required to modify the quality of a municipal waste effluent for either recycling or reuse purposes is described. A procedure is described for analyzing water reuse alternatives within a framework of regional water supply and waste water disposal planning and management.

  15. External costs and taxes in heat supply systems

    International Nuclear Information System (INIS)

    Karlsson, Aasa; Gustavsson, Leif

    2003-01-01

    A systems approach was used to compare different heating systems from a consumer perspective. The whole energy system was considered from natural resources to the required energy services. District heating, electric heat pumps, electric boilers, natural-gas-, oil- or pellet-fired local boilers were considered when supplying heat to a detached house. The district heat production included wood-chip-fired and natural-gas-fired cogeneration plants. Electricity other than cogenerated electricity was produced in wood-chip- and natural-gas-fired stand-alone power plants. The analysis includes four tax scenarios, as well as the external cost of environmental and health damage arising from energy conversion emission based on the ExternE study of the European Commission. The most cost-efficient systems were the natural-gas and oil boiler systems, followed by the heat pump and district heating systems, when the external cost and taxes were excluded. When including the external costs of CO 2 emission, the wood-fuel-based systems were much more cost efficient than the fossil-fuel-based systems, also when CO 2 capture and storage were applied. The external costs are, however, highly uncertain. Taxes steer towards lowering energy use and lowering CO 2 emission if they are levied solely on all the fossil-fuel-related emission and fuel use in the systems. If consumer electricity and heat taxes are used, the taxes have an impact on the total cost, regardless of the fuel used, thereby benefiting fuel-based local heating systems. The heat pump systems were the least affected by taxes, due to their high energy efficiency. The electric boiler systems were the least cost-efficient systems, also when the external cost and taxes were included

  16. Effects of boosting the supply temperature on pipe dimensions of low-energy district heating networks

    DEFF Research Database (Denmark)

    Tol, Hakan; Svendsen, Svend

    2015-01-01

    This paper presents a method for the dimensioning of the low-energy District Heating (DH) piping networks operating with a control philosophy of supplying heat in low-temperature such as 55 °C in supply and 25°C in return regularly while the supply temperature levels are being boosted in cold...... winter periods. The performance of the existing radiators that were formerly sized with over-dimensions was analyzed, its results being used as input data for the performance evaluation of the piping network of the low-energy DH system operating with the control philosophy in question. The optimization...

  17. Flexible and stable heat energy recovery from municipal wastewater treatment plants using a fixed-inverter hybrid heat pump system

    International Nuclear Information System (INIS)

    Chae, Kyu-Jung; Ren, Xianghao

    2016-01-01

    Highlights: • Specially designed fixed-inverter hybrid heat pump system was developed. • Hybrid operation performed better at part loads than single inverter operation. • The applied heat pump can work stably over a wide range of heat load variations. • Heat energy potential of treated effluent was better than influent. • The heat pump’s COP from the field test was 4.06 for heating and 3.64 for cooling. - Abstract: Among many options to improve energy self-sufficiency in sewage treatment plants, heat extraction using a heat pump holds great promise, since wastewater contains considerable amounts of thermal energy. The actual heat energy demand at municipal wastewater treatment plants (WWTPs) varies widely with time; however, the heat pumps typically installed in WWTPs are of the on/off controlled fixed-speed type, thus mostly run intermittently at severe part-load conditions with poor efficiency. To solve this mismatch, a specially designed, fixed-inverter hybrid heat pump system incorporating a fixed-speed compressor and an inverter-driven, variable-speed compressor was developed and tested in a real WWTP. In this hybrid configuration, to improve load response and energy efficiency, the base-heat load was covered by the fixed-speed compressor consuming relatively less energy than the variable-speed type at nominal power, and the remaining varying load was handled by the inverter compressor which exhibits a high load-match function while consuming relatively greater energy. The heat pump system developed reliably extracted heat from the treated effluent as a heat source for heating and cooling purposes throughout the year, and actively responded to the load changes with a high measured coefficient of performance (COP) of 4.06 for heating and 3.64 for cooling. Moreover, this hybrid operation yielded a performance up to 15.04% better on part loads than the single inverter operation, suggesting its effectiveness for improving annual energy saving when

  18. Bio-charcoal production from municipal organic solid wastes

    Science.gov (United States)

    AlKhayat, Z. Q.

    2017-08-01

    The economic and environmental problems of handling the increasingly huge amounts of urban and/or suburban organic municipal solid wastes MSW, from collection to end disposal, in addition to the big fluctuations in power supply and other energy form costs for the various civilian needs, is studied for Baghdad city, the ancient and glamorous capital of Iraq, and a simple control device is suggested, built and tested by carbonizing these dried organic wastes in simple environment friendly bio-reactor in order to produce low pollution potential, economical and local charcoal capsules that might be useful for heating, cooking and other municipal uses. That is in addition to the solve of solid wastes management problem which involves huge human and financial resources and causes many lethal health and environmental problems. Leftovers of different social level residential campuses were collected, classified for organic materials then dried in order to be supplied into the bio-reactor, in which it is burnt and then mixed with small amounts of sugar sucrose that is extracted from Iraqi planted sugar cane, to produce well shaped charcoal capsules. The burning process is smoke free as the closed burner’s exhaust pipe is buried 1m underground hole, in order to use the subsurface soil as natural gas filter. This process has proved an excellent performance of handling about 120kg/day of classified MSW, producing about 80-100 kg of charcoal capsules, by the use of 200 l reactor volume.

  19. Solar heating for a village; Ein Dorf heizt solar

    Energy Technology Data Exchange (ETDEWEB)

    Roepcke, Ina

    2013-07-05

    In Buesingen (administrative district of Konstanz) a solar thermal system with 1091 sqm collector area is put into operation. Together with two wood chip boilers they supply more than 100 private and municipal buildings with regenerative heat. [German] In Buesingen im Landkreis Konstanz ist eine solarthermische Anlage mit 1091 qm Kollektorflaeche in Betrieb gegangen. Zusammen mit zwei Hackschnitzelkesseln versorgt sie ueber 100 private und kommunale Gebaeude mit regenerativer Waerme.

  20. A thermoelectric-conversion power supply system using a strontium heat source of high-level radioactive nuclear waste

    International Nuclear Information System (INIS)

    Chikazawa, Yoshitaka

    2011-01-01

    A thermoelectric-conversion power supply system with radioactive strontium in high-level radioactive waste has been proposed. A combination of Alkali Metal Thermo-Electric Conversion (AMTEC) and a strontium fluoride heat source can provide a compact and long-lived power supply system. A heat source design with strontium fluoride pin bundles with Hastelloy cladding and intermediate copper has been proposed. This design has taken heat transportation into consideration, and, in this regard, the feasibility has been confirmed by a three-dimensional thermal analysis using Star-CD code. This power supply system with an electric output of 1 MW can be arranged in a space of 50 m 2 and approximately 1.1 m height and can be operated for 15 years without refueling. This compact and long-lived power supply is suitable for powering sources for remote places and middle-sized ships. From the viewpoint of geological disposal of high-level waste, the proposed power supply system provides a financial base for strontium-cesium partitioning. That is, a combination of minor-actinide recycling and strontium-cesium partitioning can eliminate a large part of decay heat in high-level waste and thus can save much space for geological disposal. (author)

  1. Changes in municipal energy supply - revision of franchise agreements and change of ownership of networks. Proceedings. Veraenderungen der kommunalen Energieversorgung - Neugestaltung von Konzessionsvertraegen und Netzuebernahme. Tagungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, H. (ed.)

    1991-01-01

    Currently, there is a demand in many communities for information and advice on future forms of local energy supply. The present discussion was triggered by the expiry of many franchise agreements by 1994 (because of the fourth draft bill to amend the restrictive trade practices act), demands to give local government more scope for action in matters of their own power generation (reference: power-and-heat cogeneration), and endeavours on the part of local government to take over power supply also in their enlarged areas after the territorial revision. Mostly, the immediate concern is to conclude new franchise agreements (either with the former or a new utility, at identical or modified conditions) and to take over responsibility for power supply. As these are fundamental local-policy decisions with far-reaching long-term consequences, a thorough analysis is required that should include technic-economic, legal, and energy- and environment-political aspects. The book contains the lectures given at the 17th meeting of the working group 'advising on energy' in Hessen, which took place in Darmstadt on October 1st, 1990 and dealt with the complex of questions 'change of ownership of networks/franchise agreements'. The contributions demonstrate and discuss the various possibilities for framing the terms of supply in their manifold dimensions and repercussions and from different angles. This is to increase the transparency of facts, arguments and opinions regarding a complex and vital sector of municipal energy policy, and to give hints to energy advisers on difficulties and points for decision that will arise and should be taken heed of in all cases where changes of an order-political nature take place. (orig./UA).

  2. Heat plan Denmark 2010. Main report; Varmeplan Danmark 2010. Hovedrapport

    Energy Technology Data Exchange (ETDEWEB)

    Dyrelund, A.; Fafner, K.; Ulbjerg, F. (and others)

    2010-09-15

    Heat Plan Denmark 2010 is an update of Heat Plan Denmark 2008 and confirms how the sector has reduced the CO{sub 2} emission in Denmark since 1980 and how this development can continue in a cost effective way to an almost CO{sub 2} neutral heating sector in 2030. The study is based on an overall least cost evaluation of the best existing technology taking into account the interaction between buildings, district heating and the power system with a large share of wind energy. It provides recommendations to the central administration, to municipalities, to district heating companies and to consumers on how to continue the development of the heating sector in the most cost effective way towards a CO{sub 2} neutral society in a sustainable way, mainly: 1) to increase the market share of District heating from 50 % to 70%; 2) to supply 70% of all new buildings with district heating; 3) to supply 30 % with heat pumps; 4) to encourage end-users to save heat and reduce the return temperature; 5) to use more renewable energy, such as waste to energy with fluegas condensation, biofuel CHP, large scale solar heating, geothermal energy and electric boilers and heat pumps to absorb surplus wind energy. (ln)

  3. Experimental study of the combined utilization of nuclear power heating plants for big towns and industrial complexes

    International Nuclear Information System (INIS)

    Neumann, J.; Barabas, K.

    1977-01-01

    The paper describes a comparison of nuclear power heating plants with an output corresponding to 1000MW(e) with plants of the same output using coal or oil. The economic aspects are compared, both as regards investment and operation costs. The comparison of the environmental aspects is performed on the atmospheric pollution from exhausts and gaseous emission and on the thermal pollutions in hydrosphere and atmosphere. Basic nuclear power plant schemes with two PWRs, each of 1500MW(th), are described. The plant supplies electric power and heat for factories and municipal heating systems (apartments, shops, and other auxiliary municipal facilities). At the same time the basic heat-flow diagram of a nuclear power heating plant is given, together with the relative losses. The study emphasizes the possible utilization of waste heat for heating glasshouses of 200m 2 . The problems of utilizing waste heat, and the needs of a big town and of industrial complexes in the vicinity of the nuclear power heating plant are also considered. (author)

  4. Method for reducing excess heat supply experienced in typical Chinese district heating systems by achieving hydraulic balance and improving indoor air temperature control at the building level

    International Nuclear Information System (INIS)

    Zhang, Lipeng; Gudmundsson, Oddgeir; Thorsen, Jan Eric; Li, Hongwei; Li, Xiaopeng; Svendsen, Svend

    2016-01-01

    A common problem with Chinese district heating systems is that they supply more heat than the actual heat demand. The reason for this excess heat supply is the general failure to use control devices to adjust the indoor temperature and flow in the building heating systems in accordance with the actual heat demand. This results in 15–30% of the total supplied heat being lost. This paper proposes an integrated approach that aims to reduce the excess heat loss by introducing pre-set thermostatic radiator valves combined with automatic balancing valves. Those devices establish hydraulic balance, and stabilize indoor temperatures. The feasibility and the energy consumption reduction of this approach were verified by means of simulation and a field test. By moving the system from centrally planned heat delivery to demand-driven heat delivery, excess heat loss can be significantly reduced. Results show that once the hydraulic balance is achieved and indoor temperatures are controlled with this integrated approach, 17% heat savings and 42.8% pump electricity savings can be achieved. The energy savings will also have a positive environmental effect with seasonal reductions of 11 kg CO_2, 0.1 kg SO_2, and 0.03 kg NO_x per heating square meter for a typical case in Harbin. - Highlights: • Two real cases reflect the temperature and flow control situation of heating systems in China. • Pre-set radiator valves with automatic balancing valves create dynamic hydraulic balance. • IDA-ICE simulation shows 17% heat saving and 48% pump electricity saving. • This approach can improve the comfort level of multi-storey/high-rise residential buildings. • This approach can reduce excess heat supply and bring out positive environmental impacts.

  5. Municipal opportunities

    International Nuclear Information System (INIS)

    Cousens, D.; Chuddy, B.; Gleeson, A.; Leckie, D.; Wahl, K.; McGarry, D.

    1997-01-01

    The panel discussing market opportunities for municipal electric companies was moderated by Markham Mayor Don Cousens. He expressed himself in favour of deregulation and was optimistic about the benefits it will bring to municipal electric utilities and their customers. Barry Chuddy, General Manager of Business Development for TransAlta Energy discussed the advantages of recent cogeneration and district energy for municipal utilities in Ontario and Quebec, and expressed his support for incentive-based regulation based on a level playing field, competitive generation, and a reasonable charge for stranded assets. Toronto City Councillor Dan Leckie described cogeneration and district energy as a tremendous opportunity to reduce the cost of doing business in the city core through local job creation and by keeping money in the local economy. Karl Wahl, General Manager of Hydro Mississauga expressed optimism that the government will move expeditiously toward competition, choice and lower-cost supply. David McGarry, President of Elecsar Engineering of Sarnia spoke about the significant job creating potential that deregulation will bring to the electrical industry. He cited several examples from Ontario and British Columbia

  6. Dual Rate Adaptive Control for an Industrial Heat Supply Process Using Signal Compensation Approach

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Tianyou; Jia, Yao; Wang, Hong; Su, Chun-Yi

    2017-07-09

    The industrial heat supply process (HSP) is a highly nonlinear cascaded process which uses a steam valve opening as its control input, the steam flow-rate as its inner loop output and the supply water temperature as its outer loop output. The relationship between the heat exchange rate and the model parameters, such as steam density, entropy, and fouling correction factor and heat exchange efficiency are unknown and nonlinear. Moreover, these model parameters vary in line with steam pressure, ambient temperature and the residuals caused by the quality variations of the circulation water. When the steam pressure and the ambient temperature are of high values and are subjected to frequent external random disturbances, the supply water temperature and the steam flow-rate would interact with each other and fluctuate a lot. This is also true when the process exhibits unknown characteristic variations of the process dynamics caused by the unexpected changes of the heat exchange residuals. As a result, it is difficult to control the supply water temperature and the rates of changes of steam flow-rate well inside their targeted ranges. In this paper, a novel compensation signal based dual rate adaptive controller is developed by representing the unknown variations of dynamics as unmodeled dynamics. In the proposed controller design, such a compensation signal is constructed and added onto the control signal obtained from the linear deterministic model based feedback control design. Such a compensation signal aims at eliminating the unmodeled dynamics and the rate of changes of the currently sample unmodeled dynamics. A successful industrial application is carried out, where it has been shown that both the supply water temperature and the rate of the changes of the steam flow-rate can be controlled well inside their targeted ranges when the process is subjected to unknown variations of its dynamics.

  7. District heating rehabilitation project in Kaerdla on Hiiumaa, Estonia. Final report

    International Nuclear Information System (INIS)

    1998-03-01

    The main objective of the project has been to assist Kaerdla Municipality with the rehabilitation of their district heating system with Danish technology, and thereby support and make it possible for the Municipality of Kaerdla to develop the district heating sector in Kaerdla and thereby also to reduce emissions of harmful gases to the environment, as well as making a much more rational and energy efficient system. The project would further on demonstrate the use of pre-insulated pipes, which are fully sealed against penetration of water as well as demonstrate the use of compact units as substations including weather compensation control systems for regulation of heat and hot tap water supply for the district heating consumers. Besides the project gives significantly decreases in energy consumption's and in the pollution from the production of energy, the objective of the project was also to put great stress on providing technical assistance to Kaerdla DH company, in order to make them capable in operation and maintenance of the new district heating system, and also to train the local operational staff in operation of the complete district heating system. The project will have a high demonstration value towards other towns in Estonia with similar problems and configurations of their heating systems. (EG)

  8. District heating rehabilitation project in Kaerdla on Hiiumaa, Estonia. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The main objective of the project has been to assist Kaerdla Municipality with the rehabilitation of their district heating system with Danish technology, and thereby support and make it possible for the Municipality of Kaerdla to develop the district heating sector in Kaerdla and thereby also to reduce emissions of harmful gases to the environment, as well as making a much more rational and energy efficient system. The project would further on demonstrate the use of pre-insulated pipes, which are fully sealed against penetration of water as well as demonstrate the use of compact units as substations including weather compensation control systems for regulation of heat and hot tap water supply for the district heating consumers. Besides the project gives significantly decreases in energy consumption`s and in the pollution from the production of energy, the objective of the project was also to put great stress on providing technical assistance to Kaerdla DH company, in order to make them capable in operation and maintenance of the new district heating system, and also to train the local operational staff in operation of the complete district heating system. The project will have a high demonstration value towards other towns in Estonia with similar problems and configurations of their heating systems. (EG)

  9. Estimation of the economical and ecological efficiency of the solar heat supply in Russia

    International Nuclear Information System (INIS)

    Marchenko, O.V.; Solomin, S.V.

    2001-01-01

    One carried out numerical study of application efficiency of solar heat supply systems in the climatic conditions of Russia with regard to their economical competitiveness with organic fuel heat conventional sources and role in reduction of greenhouse gas releases. One defined the regions where (under certain conditions) application of solar energy to generate low-potential heat may be reasonable [ru

  10. Heat supply analysis of steam reforming hydrogen production process in conventional and nuclear

    International Nuclear Information System (INIS)

    Siti Alimah; Djati Hoesen Salimy

    2015-01-01

    Tile analysis of heat energy supply in the production of hydrogen by natural gas steam reforming process has been done. The aim of the study is to compare the energy supply system of conventional and nuclear heat. Methodology used in this study is an assessment of literature and analysis based on the comparisons. The study shows that the heat sources of fossil fuels (natural gas) is able to provide optimum operating conditions of temperature and pressure of 850-900 °C and 2-3 MPa, as well as the heat transfer is dominated by radiation heat transfer, so that the heat flux that can be achieved on the catalyst tube relatively high (50-80 kW/m"2) and provide high thermal efficiency of about 85 %. While in the system with nuclear energy, due to the demands of safety, process operating at less than optimum conditions of temperature and pressure of 800-850 °C and 4.5 MPa, as well as the heat transfer is dominated by convection heat transfer, so that the heat flux that can be achieved catalyst tube is relatively low (1020 kW/m"2) and it provides a low thermal efficiency of about 50 %. Modifications of reformer and heat utilization can increase the heat flux up to 40 kW/m"2 so that the thermal efficiency can reach 78 %. Nevertheless, the application of nuclear energy to hydrogen production with steam reforming process is able to reduce the burning of fossil fuels which has implications for the potential decrease in the rate of CO2 emissions into the environment. (author)

  11. EXPERIENCE OF UTILIZATION OF CAPACITY BANKS AND SCHEMES OF FREQUENCY REGULATION IN MUNICIPAL CENTRALIZED HEATING SYSTEM OF CHISINAU

    Directory of Open Access Journals (Sweden)

    CHERNEI M

    2013-04-01

    Full Text Available The current paper provides a brief summary of the district heating system of the municipality Chisinau, including heat power sources, heat distribution network, production and consumption development over the past two decades and other data. Also, the priority investment projects realized by JSC "Termocom" are being presented. The company had implemented an automated monitoring system for the heat power production, transportation and distribution. For many years, the company used bellows pipes with polyurethane insulation, ball valves and plate heat exchangers. 14 out of 21 district heating boiler stations were upgraded 10 were completely automated having as a result no further need in full-time duty personnel there. The experience gained in the implementation of capacity banks and frequency inverters, summarizing the benefits and achieved results, is also presented in the current paper. It is to be underlined that in 2011 the company achieved decrease in electricity consumption by about 30% in comparison with 2005.

  12. Trends in municipal-well installations and aquifer utilization in southeastern Minnesota, 1880-1980

    Science.gov (United States)

    Woodward, D.G.

    1985-01-01

    Water distributed by municipal systems has been the largest off-stream use of water in southeastern Minnesota for the past 100 years. Water pumped by these systems in 1980 totaled 102.3 billion gallons, with 60.1 billion gallons supplied by ground water. Ground water supplies 294 of the 309 municipal systems in the area.

  13. Ground Source Heat Supply in Moscow Oblast: Temperature Potential and Sustainable Depth of Heat Wells

    Science.gov (United States)

    Vasil'ev, G. P.; Gornov, V. F.; Dmitriev, A. N.; Kolesova, M. V.; Yurchenko, V. A.

    2018-01-01

    The paper is devoted to a problem of increasing the efficiency of low-potential geothermal heat in heat pump systems of residential buildings the Moscow oblast of Russia, including Moscow. Estimates of a natural geothermal potential in the Moscow oblast (based on climatological data for the period from 1982 to 2011) are presented and a "Typical climatic year of natural soil temperature variations for the geoclimatic conditions of the Moscow oblast, including the city of Moscow" is proposed. Numerical simulation of the influence of geothermal energy potential and the depth of heat wells on the efficiency of ground source heat pump systems for the heat supply of residential buildings is carried out. Analysis of the numerical simulation showed that the operation of a heat pump system in a house heating mode under the geoclimatic conditions of the Moscow oblast leads to a temperature drop of the heat-exchange medium circulating through heat wells to 5-6°C by the end of the first 10 years of operation, and the process stabilizes by the 15th year of operation, and further changes in the heat-exchange medium temperature do not any longer significantly affect the temperature of the heat-exchange medium in the heat well. In this case, the exact dependence of the heat-exchange medium temperature drop on the depth is not revealed. Data on the economically expedient heat well depth for the conditions of the Moscow oblast ensuring a net present value for the whole residential building life cycle are presented. It is found that the heat well depth of 60 m can be considered as an endpoint for the Moscow oblast, and a further heat well deepening is economically impractical.

  14. An Analysis of Total Phosphorus Dispersion in Lake Used As a Municipal Water Supply.

    Science.gov (United States)

    Lima, Rômulo C; Mesquita, André L A; Blanco, Claudio J C; Santos, Maria de Lourdes S; Secretan, Yves

    2015-09-01

    In Belém city is located the potable water supply system of its metropolitan area, which includes, in addition to this city, four more municipalities. In this water supply complex is the Água Preta lake, which serves as a reservoir for the water pumped from the Guamá river. Due to the great importance of this lake for this system, several works have been devoted to its study, from the monitoring of the quality of its waters to its hydrodynamic modeling. This paper presents the results obtained by computer simulation of the phosphorus dispersion within this reservoir by the numerical solution of two-dimensional equation of advection-diffusion-reaction by the method θ/SUPG. Comparing these results with data concentration of total phosphorus collected from November 2008 to October 2009 and from satellite photos show that the biggest polluters of the water of this lake are the domestic sewage dumps from the population living in its vicinity. The results obtained indicate the need for more information for more precise quantitative analysis. However, they show that the phosphorus brought by the Guamá river water is consumed in an area adjacent to the canal that carries this water into the lake. Phosphorus deposits in the lake bottom should be monitored to verify their behavior, thus preventing the quality of water maintained therein.

  15. Master plan study - District heating Kohtla-Jaerve and Johvi municipalities. Estonia. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The main deficiencies of the district heating system in Kohtla-Jaerve, Ahtme and Johvi (Estonia) were identified as being: Inefficiency of the heat and power production plants; Lack of means for the consumers to control their consumption of energy due to the existing constant flow system; The environmental impact from heat and power production based on oil shale; Water and heat losses from the network; Low heat intensity in the Johvi area. Investigations indicate that improvement should have first priority at the Kohtla-Jaerve power plant, total investment is estimated at US D 60,3 million, of which US D 48 million are foreign costs. The cash flow will be negative in the first half of the projects lifetime. Estii Energia should be involved in the financing of the project. At the present price level, introduction of variable flow does not significantly improve the financial viability of the project, and the improvement of the district heating system might be carried out at a later stage, when the tariff has found a more stable level and the financial viability will be more significant. Implementation of new boilers in the Kohtla-Jaerve power plant. Circulating Fluidized Bed boilers, as well as electrostatic filters and estimated to reduce the environmental impact considerably. A more in depth study of the environmental impact from utilisation of oil shale should be carried out, also in order to inform possible investors of risk of investing in the oil shale industry. It will be more expensive to supply Johvi as an independent district heating system than if Johvi is supplied from Ahtme. The results arrived at are based on a range of the crucial assumptions that: the price of oil shale is expected to reach 75% of the price of coal, the sales price of electricity from plants is 62% of the consumer price, the exchange rate of the Estonian currency is kept constant to the DEM and that the inflation is Estonia will decline from 21% to 2,3% in 2005. (ARW)

  16. Municipal solid waste generation in municipalities: Quantifying impacts of household structure, commercial waste and domestic fuel

    International Nuclear Information System (INIS)

    Lebersorger, S.; Beigl, P.

    2011-01-01

    Waste management planning requires reliable data concerning waste generation, influencing factors on waste generation and forecasts of waste quantities based on facts. This paper aims at identifying and quantifying differences between different municipalities' municipal solid waste (MSW) collection quantities based on data from waste management and on socio-economic indicators. A large set of 116 indicators from 542 municipalities in the Province of Styria was investigated. The resulting regression model included municipal tax revenue per capita, household size and the percentage of buildings with solid fuel heating systems. The model explains 74.3% of the MSW variation and the model assumptions are met. Other factors such as tourism, home composting or age distribution of the population did not significantly improve the model. According to the model, 21% of MSW collected in Styria was commercial waste and 18% of the generated MSW was burned in domestic heating systems. While the percentage of commercial waste is consistent with literature data, practically no literature data are available for the quantity of MSW burned, which seems to be overestimated by the model. The resulting regression model was used as basis for a waste prognosis model (Beigl and Lebersorger, in preparation).

  17. Study of waste-heat recovery and utilization at the Farmington Municipal Power Plant. Final report, December 1, 1980-June 30, 1981

    Energy Technology Data Exchange (ETDEWEB)

    Leigh, G.G.; Edgel, W.R.; Feldman, K.T. Jr.; Moss, E.J.

    1982-03-01

    An examination was made of the technical and economc feasibility of utilizing waste heat from the Farmington Municipal Power Plant. First, the production cycles of the natural-gas-fired plant were assessed to determine the quantity and quality of recoverable waste heat created by the plant during its operation. Possibilities for utilizing waste heat from the exhaust gases and the cooling water were then reviewed. Hot water systems that can be used to retrieve heat from hot flue gases were investigated; the heated water can then be used for space heating of nearby buildings. The potential use of waste heat to operate a refrigeration plant was also analyzed. The use of discharged cooling water for hydroelectric generation was studied, as well as its application for commercial agricultural and aquaculture enterprises.

  18. LEAP: local environmental action plan. Municipality of Sopishte

    International Nuclear Information System (INIS)

    2004-01-01

    The establishment of the Municipality of Sopishte was preceded by the development of a kind of suburban settlement of Skopje, basically composed of illegally constructed individual houses for living. As a result from economic activities in the Municipality and the impacts from human factor, there are problems related to the disturbance of the quality of the basic environmental quality factors (water, air and soil), as well as threat to biological diversity and natural values and rarities. The Municipality of Sopishte is situated in hilly-mountain area. Significant sources of air pollution have not been recorded (in terms of industrial facilities) caused by the household neglectible air pollution caused by traffic. The Municipality is very poor in water resources. Almost 90% of the Municipality's territory are without river or stream. A potential source of water supply in this area is the river of Patishka, which is currently not used for water supply purposes. The solid waste, generated basically by the households, is not properly disposed (most frequently dumped on illegal dumping sites on the territory of the Municipality) and represents a serious problem making impacts on the quality of the environment. On the basis of the evaluation of identified environmental problems, priority activities required to be undertaken in short and medium term have been set up. Financial constrains have been taken into account in this regard. The proposed Action Plan reflects the observed needs of the population of the Municipality of Sopishte and the perception of the key problems

  19. Typhoon and elevated radon level in a municipal water supply

    International Nuclear Information System (INIS)

    Mao, Cheng-Hsin; Weng, Pao-Shan

    2000-01-01

    The Municipal Water Supply at Hsinchu City is a water treatment plant using poly- aluminum chloride (PAC) for coagulation and then followed by precipitation and filtration. Its capacity is 70,000 m 3 /day. The raw water is drawn from the nearby river. Since the subject of interest is the radon level during typhoon season, the sampling period was from March to December 1999. Commercially available electret was used for water samples taken from the five ponds in the plant. This technique relies on the measurement of radon in air above a water sample enclosed in a sealed vessel. The concentration of airbone radon released from water was determined by means of the electret ion chamber. During the first sampling period there came two typhoons. One is called Magie during June 10-17, and the other called Sam during August 20-26. The first typhoon led to the radon level measured from the water samples as high as 705 Bq/m 3 , while the second caused even higher radon level as high as 772 Bq/m 3 . Similar results were obtained for the second sampling period after August till December 1999. For those measured without typhoon influence, the average radon was lower from the coagulation pond yet without coagulation process during March through August 1999. However, water samples taken from the pond after precipitation did not show similar results in radon level. (author)

  20. Change in heat load profile for typical Danish multi-storey buildings when energy-renovated and supplied with low-temperature district heating

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, Svend

    2013-01-01

    ) supply. When end-use-savings are implemented in buildings concurrent with the application of low-temperature district heating (DH) (supply=55°C, return=25°C) the heat demand profiles for the individual buildings will change. The reduction in peak load is important since it is the dimensioning foundation...... for the future DH-systems and in order to avoid oversized RE-based capacity, a long-term perspective needs to be taken. The results show that it is possible to design the DH-plants based on an average value of the 5 days with highest daily average loads without compromising with indoor thermal comfort. Applying...

  1. Performance of Chilled Beam with Radial Swirl Jet and Diffuse Ceiling Air Supply in Heating Mode

    DEFF Research Database (Denmark)

    Bertheussen, Bård; Mustakallio, Panu; Melikov, Arsen Krikor

    2013-01-01

    ). The room air temperature was kept at 21 °C. Tracer gas was used to simulate pollution from floor and desk. The experimental conditions comprised: 1) night time without heat sources in the room; the room air conditioning system was used to heat up the room; 2) heat load generated by an occupant (simulated...... by dressed thermal manikin) and a laptop; 3) heating by convectors positioned under the window (convectors used alone and convector used together with CSW supplying isothermal air for ventilation). The heat distribution provided by the systems was not effective compare to the distribution provided......The performance of diffuse ceiling air supply and chilled beam with swirl jet (CSW) in heating mode (winter situation) was studied and compared with regard to the generated indoor environment. An office mock-up with one occupant was simulated in a test room (4.5 x 3.95 x 3.5 m3 (L x W x H...

  2. Heating of roads. Heat consumption and heat output as a function of climate, construction, demands on surface conditions and principle of heat supply. Uppvaermning av vaegar

    Energy Technology Data Exchange (ETDEWEB)

    Magnusson, R

    1977-01-01

    In this work analytical formulas for calculation of temperatures in a heated roadbed are given. The heat flux from a heated surface has been studied. The methods for snowclearence on different types of roads have been investigated. The construction work has been studied. The analytical formulas have been evaluated by comparison between calculated temperatures and temperatures measured in field and laboratory. The heat transfer coefficients in those formulas have been developed empirically by tests in laboratory and field. Surfaces with different types of traffic are divided into three classes according to the demands for snow removal. The construction work has been divided into cost elements. This has given a basis for calculating the economic effects of alternative designs. By this work has been developed a method useful on one hand for calculation of the optimum principle of regulation of the supply of heat and on the other hand for the design of the heat installations in the road.

  3. Planning of the district heating system in copenhagen from an economic perspective comparing energy-savings versus fossil-free supply

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, Svend

    geothermal heating plants, may lead to oversized heating plants that are too expensive to build compared to implementing energy savings. Therefore reducing heat demand of existing buildings before investing in supply capacity will save society half the investment, indicating the importance of carrying out......The Danish government has adopted a long-term energy policy of being independent of fossil fuels by 2050, and that the energy supply for buildings should be independent of fossil fuels by 2035. Therefore, urgent action is needed to meet the requirements for the future energy system. One way...... of becoming independent of fossil fuels is to energy upgrade the existing building stock and change the energy supply to renewable energy sources. A sustainable way of providing space heating (SH) and domestic hot water (DHW) to buildings in densely populated areas is through the use of district heating (DH...

  4. Active Power Flow Optimization of Industrial Power Supply with Regard to the Transmission Line Conductor Heating

    Directory of Open Access Journals (Sweden)

    Leyzgold D.Yu.

    2015-04-01

    Full Text Available This article studies the problem of the transmission line conductor heating effect on the active power flows optimization in the local segment of industrial power supply. The purpose is to determine the optimal generation rating of the distributed power sources, in which the power flow values will correspond to the minimum active power losses in the power supply. The timeliness is the need to define the most appropriate rated power values of distributed sources which will be connected to current industrial power supply. Basing on the model of active power flow optimization, authors formulate the description of the nonlinear transportation problem considering the active power losses depending on the transmission line conductor heating. Authors proposed a new approach to the heating model parameters definition based on allowable current loads and nominal parameters of conductors as part of the optimization problem. Analysis of study results showed that, despite the relatively small active power losses reduction to the tune 0,45% due to accounting of the conductors heating effect for the present configuration of power supply, there are significant fluctuations in the required generation rating in nodes of the network to 9,32% within seasonal changes in the outer air temperature. This fact should be taken into account when selecting the optimum power of distributed generation systems, as exemplified by an arbitrary network configuration.

  5. Mobile central heating plant ensures the supply during the power-plant modernization. Planning-safe reconstruction; Mobile Heizzentrale sichert Versorgung waehrend Kraftwerksmodernisierung. Planungssicherer Umbau

    Energy Technology Data Exchange (ETDEWEB)

    Bernhard, Petra [Mobiheat GmbH, Friedberg (Germany). Presse- und Oeffentlichkeitsarbeit

    2012-09-15

    During the comprehensive energetic retrofitting of district heating plants in the spa resort of Badenweiler (Federal Republic of Germany) a mobile 2-MW heating plant from Mobilheat (Ebersberg, Federal Republic of Germany) was used for the heat supply. Thus, the installation of environmental friendly energy supply based on cogeneration plants could be implemented with planning security. This particularly was important because, among other things, the traditional spa resort, the Kurhaus as well as hotels and private customers depend on the heat supply system. These buildings have be supplied with thermal water also in the summer.

  6. PECULIARITIES OF FORMATION OF CORPORATE STRUCTURES IN THE HEAT SUPPLY SYSTEM OF THE REGION

    Directory of Open Access Journals (Sweden)

    Oleg A. Donichev

    2013-01-01

    Full Text Available The article contains the research results of formation and functioning of corporate structures of the regional heat power engineering. A geometrical model of interactions between hierarchy levels of this structure is proposed. The role of the government in an improvement of the effectiveness of the heat supply system of regions is proved.

  7. Municipal management and geo-hydrological aspects of importance in the potable water supply of Lindley

    Directory of Open Access Journals (Sweden)

    Eric Nealer

    2014-07-01

    Full Text Available When the South African Government in 1998 re-demarcated its 283 municipalities so that they completely cover the country in a “wall-to-wall” manner, their main focus was on growing local economies and maintaining the provision of an increased number of diverse and more complex basic municipal services to new geographical areas consisting of millions of citizens who might previously had been neglected. In most of the instances the newly established and merged municipalities were demarcated according to geographical aspects inherited from the previous political dispensation, historical municipal areas and magisterial district farm names. The fact that these municipal government jurisdictions for the purpose of improving co-operative municipal- and integrated water resources management (IWRM, in most instances do not correspond with environmental and physical land features such as the demarcated surface water (rivers drainage regions’ boundaries, could lead to the ineffective, inefficient and non-economic municipal management of water, sanitation and environmental services. The aforementioned is a case with reference to water services management in the Free State Province town of Lindley located in the Vals River catchment and the Nketoana Local Municipality’s area of jurisdiction. An extensive literature review, the use and study of geographic tools such as maps, ortho- photos and information data bases, as well as two field visits to the area, enabled the researchers to identify the essential geographical, geo-hydrological and municipal management aspects of importance for the potable water service providers and managers in the Lindley municipal area. The researchers argue that effective trans-boundary municipal management through simunye-type co-operative governance and IWRM must be facilitated in the Vals River surface water catchment between the respective local- and district municipalities for the benefit of the Lindley, Arlington

  8. The optimization of heat supply centralization on the basis of boiler-rooms

    International Nuclear Information System (INIS)

    Arshakian, D.

    1992-01-01

    In this article the problem of finding of the optimum of heat supply centralization of towns and insutrial districts on the basis of boiler-rooms, using organic and nuclear fuel in the natural-climatic conditions and town-building transitions of Armenia is considered. (orig.) [de

  9. Study on the Development of an Optimal Heat Supply Control Algorithm for Group Energy Apartment Buildings According to the Variation of Outdoor Air Temperature

    Directory of Open Access Journals (Sweden)

    Dong-Kurl Kwak

    2012-05-01

    Full Text Available In the present study, we have developed an optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in a group energy apartment. Heating load variation of a group energy apartment building according to the outdoor air temperature was predicted by a correlation obtained from calorimetry measurements of all households in the apartment building. Supply water temperature and mass flow rate were simultaneously controlled to minimize the heat loss rate through the distribution pipe line. A group heating apartment building located in Hwaseong city, Korea, which has 1473 households, was selected as the object building to test the present heat supply algorithm. Compared to the original heat supply system, the present system adopting the proposed control algorithm reduced the heat loss rate by 10.4%.

  10. Municipal solid waste generation in municipalities: quantifying impacts of household structure, commercial waste and domestic fuel.

    Science.gov (United States)

    Lebersorger, S; Beigl, P

    2011-01-01

    Waste management planning requires reliable data concerning waste generation, influencing factors on waste generation and forecasts of waste quantities based on facts. This paper aims at identifying and quantifying differences between different municipalities' municipal solid waste (MSW) collection quantities based on data from waste management and on socio-economic indicators. A large set of 116 indicators from 542 municipalities in the Province of Styria was investigated. The resulting regression model included municipal tax revenue per capita, household size and the percentage of buildings with solid fuel heating systems. The model explains 74.3% of the MSW variation and the model assumptions are met. Other factors such as tourism, home composting or age distribution of the population did not significantly improve the model. According to the model, 21% of MSW collected in Styria was commercial waste and 18% of the generated MSW was burned in domestic heating systems. While the percentage of commercial waste is consistent with literature data, practically no literature data are available for the quantity of MSW burned, which seems to be overestimated by the model. The resulting regression model was used as basis for a waste prognosis model (Beigl and Lebersorger, in preparation). Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Development of 8 MW Power Supply Based on Pulse Step Modulation Technique for Auxiliary Heating System on HL-2A

    International Nuclear Information System (INIS)

    Xu Weidong; Xuan Weimin; Yao Lieying; Wang Yingqiao

    2012-01-01

    The high voltage power supply (HVPS) based on pulse step modulation (PSM) has already been developed for the auxiliary heating system on HL-2A. This power supply consists of many switch power supplies, and its output voltage can be obtained by modulating their delay time and pulse widths. The PSM topology and control principle are presented in this paper. The simple algorithms for the control system are explained clearly. The switch power supply (SPS) module has been built and the test results show it can meet the requirements of the auxiliary heating system. Now, 112 SPS modules and the whole system have already been developed. Its maximum output is about 72 kV/93 A. The protection time is less than 5 μs. The different outputs of this power supply are used for the electron cyclotron resonant heating (ECRH) system with different duty ratios. The experimental results of the entire system are presented. The results indicate that the whole system can meet the requirements of the auxiliary heating system on HL-2A.

  12. Nitrate distribution and potential attenuation mechanisms of a municipal water supply bedrock aquifer

    International Nuclear Information System (INIS)

    Opazo, Tomás; Aravena, Ramón; Parker, Beth

    2016-01-01

    The Silurian bedrock aquifer constitutes a major aquifer system for groundwater supply across the Ontario province in Canada. The application of natural and industrial fertilizers near urban centers has led to groundwater NO_3"−-N concentrations that sometimes have exceeded the drinking water limit, posing a threat to the usage of groundwater for the human consumption. Therefore, there is a growing interest and concern about how nitrate is being leached, transported and potentially attenuated in bedrock aquifers. This study assesses the local distribution of groundwater NO_3"− in the up-gradient area of two historically impacted municipal wells, called Carter Wells, in the City of Guelph, Canada, in order to evaluate the potential nitrate attenuation mechanisms, using both groundwater geochemical and isotopic analysis ("3H, δ"1"5N-NO_3, δ"1"8O-NO_3, δ"1"8O-SO_4, δ"3"4S-SO_4) and a detailed vertical hydrogeological and geochemical bedrock characterization. The results indicate that probably the main source of nitrate to the Carter Wells is the up-gradient Arkell Research Station (ARS), an agricultural research facility where manure has been historically applied. The overburden and bedrock groundwater with high NO_3 concentrations at the ARS exhibits a manure-related δ"1"5N and δ"1"8O signature, isotopically similar to the high nitrate in the down-gradient groundwater from domestic wells and from the Carter Wells. The nitrate spatial distribution appears to be influenced and controlled by the geology, in which more permeable rock is found in the Guelph Formation which in turn is related to most of the high NO_3"− groundwater. The presence of an underlying low permeability Eramosa Formation favors the development of oxygen-depleted conditions, a key factor for the occurrence of denitrification. Groundwater with low NO_3"−-N concentrations associated with more oxygen-limited conditions and coincident with high SO_4"2"− concentrations are related to more

  13. Supply of domestic hot Water at comfortable temperatures by low-temperature district heating without risk of Legionella

    DEFF Research Database (Denmark)

    Yang, Xiaochen

    disinfection efficacy for Legionella if supplied by LTDH, and inject no additives into the water. Thus, they can be considered as feasible sterilization solutions. In terms of the DHW system design methods, in addition to ensure the safe and hygiene DHW supply, the potential DHW systems should also...... temperature for space heating but lower than LTDH. Therefore, to meet the comfort and hygiene requirements for DHW supply, supplementary heating methods should be combined. However, one obstacle to realize the LTDH/ULTDH is the concern of the violation of the comfort and hygiene requirements of DHW supply....... According to the Danish standard, the supply for DHW should be able to reach 45 °C for the kitchen use and 40 °C for other uses for comfort. Regarding to the hygiene requirements, large DHW system with DHW storage tank and circulation has to use high temperature regime to get rid of Legionella. The storage...

  14. Influencing the central heating technologies installed in homes: The role of social capital in supply chain networks

    International Nuclear Information System (INIS)

    Wade, Faye; Shipworth, Michelle; Hitchings, Russell

    2016-01-01

    The likely installation of, and potential energy savings from, low carbon technologies in domestic buildings is not only dependent on those who fit them, but also the broader supply chains of which they are part. Despite this, the role of supply chain actors has been largely overlooked in strategies seeking to encourage the installation of more sustainable domestic heating technologies. With reference to central heating, this paper responds through an ethnographic analysis of how plumbers' merchants and sales representatives can influence the work of heating installers in the United Kingdom. It applies two dimensions of the concept of ‘social capital’: relational and structural. Relational social capital focuses on the trust, loyalty and reciprocity at play in relations, whilst structural social capital considers how the strength of tie can influence those to whom people turn for advice and support. Together, these ideas demonstrate how relationships amongst these groups can serve to influence product choice and facilitate information exchange. The paper concludes by discussing how these supply chains might be engaged with as a means of encouraging the installation of low carbon domestic technologies. - Highlights: •Ethnography is used to investigate the relationships in heating supply chains. •Social capital is seen to be an important part of these relationships. •These relationships could help in the promotion of low carbon technologies.

  15. Variations of electric power and district heat supply in a city with 300,000 inhabitants; Varianten zur Strom- und Fernwaermeversorgung einer 300 000-Einwohner Stadt

    Energy Technology Data Exchange (ETDEWEB)

    Huevel, B.

    1997-12-31

    After the end of the regulation in 1997 which demanded the use of German coal, the municipal public utility will have several possibilities to substitute its own energy generation. Several variations are compared with each other taking into account technical and economic aspects. The variations are the continued operation of coal fuelled cogeneration power plant, the installation of a gas turbine with waste heat boiler to achieve a combined cycle power generation or the contribution to a large combined cycle power plant of the regional public utility. The comparison ends with the decision for one variation. The electric power and heat supply of the city of Karlsruhe is used as an example for the comparison. (orig./AKF) [Deutsch] Nach dem Auslaufen der Einsatzverpflichtung von deutscher Steinkohle 1997 eroeffnen sich dem kommunalen Versorgungsunternehmen verschiedene Moeglichkeiten, die Eigenerzeugung zu substituieren. Unter technischen und wirtschaftlichen Aspekten werden dazu Varianten gegenuebergestellt, wie Weiterbetrieb eines kohlebefeuerten Heizkraftwerkes mit Importkohle, Installation einer Gasturbine mit Abhitzekessel zur Realisierung eines GuD-Prozesses oder Beteiligung an einer grossen GuD des Regionalversorgers. Die Gegenueberstellung endet mit der Entscheidung fuer eine Variante. Die Strom- und Waermeversorgung der Stadt Karlsruhe wird als Beispiel fuer die Betrachtung verwendet. (orig./AKF)

  16. The small-scale production of hydrogen, with the co-production of electricity and district heat, by means of the gasification of municipal solid waste

    International Nuclear Information System (INIS)

    Hognert, Johannes; Nilsson, Lars

    2016-01-01

    Highlights: • Outline of a process for handling municipal solid waste potentially leading to reduced use of fossil transportation fuels. • The integration of waste gasification into a district heat plant leads to excellent energy efficiency. • Analysis based on actual production data from a district heat plant over the period of one year. • Simulation of a plant with productions of heat, power and gaseous hydrogen. - Abstract: Reducing the use of fossil fuels and increasing the recycling of waste are two important challenges for a sustainable society. Fossil fuels contribute to global warming whilst waste causes the pollution of land, water and air. Alternative fuels and innovative waste management systems are needed to address these issues. In this study a gasification process, fuelled with municipal solid waste, was assumed to be integrated into a heat plant to produce hydrogen, electricity and district heat. A whole system, which includes a gasification reactor, heat plant, steam cycle, pressure swing adsorption, gas turbine and compressors was modelled in Microsoft Excel and an energy balance of the system was solved. Data from the scientific literature were used when setting up the heat and mass balances of the gasification process as well as for assessment of the composition of the syngas. The allocation of energy of the products obtained in the process is 29% hydrogen, 26% electricity and 45% district heat. A significant result of the study is the high energy efficiency (88%) during the cold period of the year when the produced heat in the system is utilized for district heat. The system also shows a competitive energy efficiency (56.5%) all year round.

  17. The ohmic heating power supply for HL-1 tokamak

    International Nuclear Information System (INIS)

    Mingrui, Z.; Jiashun, C.

    1986-01-01

    A combination of capacitor banks, inductor and DC Fly wheel-Generator sets are used as ohmic heating power supply (OHPS) for HL-1, which is the largest tokamak in China. This system can give changeable waveform of current in a simple way, because of the use of protection for capacitor banks by changeable connection in easy way. Since the technology of forced zero current in the commutating breaker and synchronous self-triggering crowbar are used, the smooth conversion between the wave front provided by discharge of the capacitor banks and the flat top sustained by the inductor and flywheel realized. The performance of the system was tested by a dummy load and the system has been used in the HL-1 experiments. It is confirmed that this system is sufficiently available for the ohmic heating and has important effects on the long plasma lasting time on the order of 1 sec

  18. Strengths and weaknesses in the supply of school food resulting from the procurement of family farm produce in a municipality in Brazil.

    Science.gov (United States)

    Soares, Panmela; Martinelli, Suellen Secchi; Melgarejo, Leonardo; Davó-Blanes, Mari Carmen; Cavalli, Suzi Barletto

    2015-06-01

    The objective of this study was to assess compliance with school food programme recommendations for the procurement of family farm produce. This study consists of an exploratory descriptive study utilising a qualitative approach based on semistructured interviews with key informants in a municipality in the State of Santa Catarina in Brazil. Study participants were managers and staff of the school food programme and department of agriculture, and representatives of a farmers' organisation. The produce delivery and demand fulfilment stages of the procurement process were carried out in accordance with the recommendations. However, nonconformities occurred in the elaboration of the public call for proposals, elaboration of the sales proposal, and fulfilment of produce quality standards. It was observed that having a diverse range of suppliers and the exchange of produce by the cooperative with neighbouring municipalities helped to maintain a regular supply of produce. The elaboration of menus contributed to planning agricultural production. However, agricultural production was not mapped before elaborating the menus in this case study and an agricultural reform settlement was left out of the programme. A number of weaknesses in the programme were identified which need to be overcome in order to promote local family farming and improve the quality of school food in the municipality.

  19. Case Studies in Low-Energy District Heating Systems: Determination of Dimensioning Methods for Planning the Future Heating Infrastructure

    DEFF Research Database (Denmark)

    Tol, Hakan; Nielsen, Susanne Balslev; Svendsen, Svend

    suggests a plan for an energy efficient District Heating (DH) system with low operating temperatures, such as 55°C supply and 25°C return; connected to low-energy buildings. Different case studies referring to typical DH planning situations could show the rational basis for the integrated planning...... of the future’s sustainable and energy efficient heating infrastructure. In this paper, a case study which focuses on dimensioning method of piping network of low-energy DH system in a new settlement, located in Roskilde Municipality, Denmark, is presented. In addition to the developed dimensioning method......, results about the optimal network layout and substation type for low-energy DH systems are also pointed out regarding to this case study. A second case study, included in this paper, focuses on technical and economical aspects of replacing natural gas heating system to low-energy DH system in an existing...

  20. Application of ground-to-air heat exchanger for preheating of supply air

    Science.gov (United States)

    Sorokins, Juris; Borodinecs, Anatolijs; Zemitis, Jurgis

    2017-10-01

    This study focuses on assessing the contribution of the passive ground-coupled air heat exchanger system to decreasing the energy consumption of air conditioning and ventilation systems for office buildings in the Latvian climate conditions. The theoretical part of the thesis deals with methods of office building ventilation, supply air preheating and heat recovery as well as particularities of using ground-coupled air heat exchangers, their design parameters and their joint impact on the thermal performance. The engineering project part includes a ventilation system for an office building with an integrated ground-coupled air heat exchanger. By simulating energy consumption of the ventilation system for a duration of one year, the thesis analyzes the contribution of the heat exchanger to the overall energy consumption, which totals 9.53 MWh and 4.02 MWh a year, according to the desired parameters of the indoor climate. The possible alternative heat recovery solutions are investigated to reach by European Regional Development Fund project Nr.1.1.1.1/16/A/048 “NEARLY ZERO ENERGY SOLUTIONS FOR UNCLASSIFIED BUILDINGS”.

  1. Heating entrepreneurship in Finland. Final report

    International Nuclear Information System (INIS)

    Tuomi, S.

    1998-01-01

    The aim of the project was to improve the feasibility of the various forms of heating entrepreneurship and to launch new heating enterprises. The project was carried out by the TTS Institute as part of the national Bioenergy Research Programme. Feasibility was studied both from the viewpoint of the entrepreneurs and of municipalities. Feasibility was improved by developing production chains in the field of heating entrepreneurship and the operability of heating plants. Establishment of new heating enterprises was promoted by producing and disseminating information to potential entrepreneurs and municipalities. The feasibility of heating entrepreneurship was studied at ten enterprises. Information was gathered by resorting to daily bookkeeping and it concerned time usage in the various work stages, fuel consumption and the amount of heat produced. According to the results of the study, the profitability of the enterprises improved with increasing experience. The functional characteristics of heating plants were studied in the light of records maintained of failures and malfunction situations. Research data were also collected by evaluating the technical solutions of heating plants and by interviewing heating entrepreneurs and their customers. The economic impact of heating entrepreneurship from the viewpoint of municipalities was studied by interviewing eight entrepreneurs. All eight heating plants were slightly different. In addition to interviews, additional research data was collected by mailing questionnaires to municipalities. In the light of the responses received, municipalities were satisfied with the operation of the enterprises. Information-dissemination and training events were organised in co-operation with regional development and information organisations. Additionally, alternative ways to realise heating entrepreneurship were demonstrated both at exhibitions and trade fairs as well as at domestic and international seminars. Guiding material on heating

  2. The participation of foreign supply companies in the promotion of solar heating systems

    International Nuclear Information System (INIS)

    Larsen, J.H.; Tveit, D.

    1995-06-01

    The extent of participation on the part of energy supply companies located in Germany, the Netherlands, Brazil and USA in the promotion of solar heating systems is investigated and various promotion projects carried out in these countries are described in detail. (AB)

  3. From electricity to heat: A discourse-analytical policy study of the energy system conversion at national, municipal and household levels

    International Nuclear Information System (INIS)

    Perman, Karin

    2009-01-01

    The aim of this thesis is to analyse how space heating for single-family houses, and energy system conversion has been constructed and discussed at national, municipal and household levels. Political documents have been studied, and interviews have been carried out with politicians, civil servants and householders in the municipality of Falun. In order to study and analyse similarities and differences between these three political levels, the following main questions were asked: In which sense is the use of electrical heating formulated as problematic? How are the causes of these problems presented, and which solutions are suggested? What are the effects of how problems, causes and solutions are constructed? At the national level, the use of electricity produced by nuclear power was considered a problem. Initially the municipality's policy documents present the same problem, but there is a change of focus to the problem of imported electricity produced by fossil fuel, and the resulting emissions. At household level, the problem was often an old and badly functioning space-heating system. But some households did not formulate a problem before they converted. Instead they were influenced by their neighbours and thereby convinced. At all three political levels, there is consensus on the households' responsibility concerning energy transition. While industry tends to be considered incapable of cutting down its energy consumption, households are expected to take the responsibility seriously. Furthermore, within the household, the heating system tends to be constructed as a predominantly male concern. At all three levels, households are perceived as dependant on economical subsidies when taking the decision to convert from electrical heating. Although it is interesting that the interviewed householders only apply this view to others than themselves. They are convinced that other households need subsidies to act in an environmentally correct way. The discourse concerning

  4. Comparative ecobalancing accounting of semi-central house heat supply from wood residues; Vergleichende Oekobilanzierung der semi-zentralen Hauswaermebereitstellung aus Holzreststoffen

    Energy Technology Data Exchange (ETDEWEB)

    Biemann, Kirsten

    2015-07-01

    In 2008 almost 40 percent of the German final energy demand was used for room heating and hot water supply. To decrease environmental burdens and to save fossil resources a restructuring of the heating sector is needed. Therefore legislation enforces higher insulation standards of buildings and a more frequent use of renewable energies as well as heating networks. Wood as a renewable and storable energy source is an attractive fuel. However, it must be used as efficiently as possible because of limited wood supplies. Connecting buildings via a heating network is a good option since bigger heating plants can operate at higher efficiencies than small heaters. However, the higher insulation standards of the buildings often oppose the construction of a heating network, because heating networks work best with high energy demands and low network lengths. Therefore the environmental and economic feasibility of new heating networks needs to be checked beforehand. This thesis explores the environmental burdens of different semi- centralized heating networks using wood residues as fuel. A semi- centralized heating network is a network with no more than 500 customers and a heating plant with less than 5 MWth. While wood residues are used in the base load plant, peak load is covered by a gas heating plant. As a method to analyze the potential environmental burdens of the heat supply a life cycle assessment according to ISO 14040/44 is used. Opposed to former life cycle assessment studies, construction and operation of the network is included in the assessment. Even though the environmental impacts of the semi- centralized heating from wood residues are dominated by the heat supply, an observation of the impacts solely at the heating plant is not sufficient. By varying the boundary conditions of the heating network two main contributors to the environmental impacts are found. In addition to the heat production at the plant the type of the buildings in the settlement has a huge

  5. Control of supply temperature

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, H; Nielsen, T S; Soegaard, H T

    1996-09-01

    For many district heating systems, e.g. the system in Hoeje Taastrup, it is desirable to minimize the supply temperature from the heat production unit(s). Lower supply temperature implies lower costs in connection with the production and distribution of heat. Factors having impact on the heat demand are for instance solar radiation, wind speed, wind direction and a climate independent part, which is a function of the time of the day/week/year. By applying an optimization strategy, which minimizes the supply temperature, it is assumed that optimal economical operation can be obtained by minimizing the supply temperature and thereby the heat losses in the system. The models and methods described in this report take such aspects into account, and can therefore be used as elements in a more efficient minimization of the supply temperature. The theoretical part of this report describes models and methods for optimal on-line control of the supply temperature in district heating systems. Some of the models and methods have been implemented - or are going to be implemented - in the computer program PRESS which is a tool for optimal control of supply temperature and forecasting of heat demand in district heating systems. The principles for using transfer function models are briefly described. The ordinary generalized predictive control (OGPC) method is reviewed, and several extensions of this method are suggested. New controller, which is called the extended generalized predictive controller (XGPC), is described. (EG) 57 refs.

  6. District Heating in Areas with Low Energy Houses

    DEFF Research Database (Denmark)

    Tol, Hakan Ibrahim

    -energy houses involved, together with the idea of utilizing booster pumps in the district heating network and (ii) use of network layouts of either a branched (tree-like) or a looped type. The methods developed were applied in a case study, the data of which was provided by the municipality of Roskilde...... in Denmark. The second case study was aimed at solving another regional energy planning scheme, one concerned with already existing houses, the heat requirements of which were currently being met by use of a natural gas grid or a conventional high-temperature district heating network. The idea considered......This PhD thesis presents a summary of a three-year PhD project involving three case studies, each pertaining to a typical regional Danish energy planning scheme with regard to the extensive use of low-energy district heating systems, operating at temperatures as low as 55°C for supply and 25°C...

  7. Public Water Supply Systems (PWS)

    Data.gov (United States)

    Kansas Data Access and Support Center — This dataset includes boundaries for most public water supply systems (PWS) in Kansas (525 municipalities, 289 rural water districts and 13 public wholesale water...

  8. Use of solar energy for heat supply under conditions of the Socialist Federated Republic of Yugoslavia

    Energy Technology Data Exchange (ETDEWEB)

    Savic, B.

    1981-01-01

    The characteristics of a flat solar energy collector are used to determine the specific heat productivity of the solar unit under meteorological conditions of Belgrade. The evaluation is made with regard for experimental data of year-round operation of hot water supply units and the seasonal use of heating units.

  9. AUTONOMOUS HEAT SUPPLY SYSTEM OF CONSUMERS WITH CONSIDERABLE DIFFERENT THERMAL INERTIA

    Directory of Open Access Journals (Sweden)

    Berzan V.P.

    2012-04-01

    Full Text Available There are examined problems occurring at the adoption of the decentralized heat energy supply system of the group of objects, which contains buildings with thermal inertia differed in thousands of times one from the other. It is studied the influence of water volume of hot-water boiler on greenhouse dynamics. It is conducted the comparison between the use ob biomass and natural gas boilers for such as objects.

  10. Demand control on room level of the supply air temperature in an air heating and ventilation system

    DEFF Research Database (Denmark)

    Polak, Joanna; Afshari, Alireza; Bergsøe, Niels Christian

    2017-01-01

    air heating and ventilation system in a high performance single family house using BSim simulation software. The provision of the desired thermal conditions in different rooms was examined. Results show that the new control strategy can facilitate maintaining of desired temperatures in various rooms......The aim of this study was to investigate a new strategy for control of supply air temperature in an integrated air heating and ventilation system. The new strategy enables demand control of supply air temperature in individual rooms. The study is based on detailed dynamic simulations of a combined....... Moreover, this control strategy enables controlled temperature differentiation between rooms within the house and therefore provides flexibility and better balance in heat delivery. Consequently, the thermal conditions in the building can be improved....

  11. Are more resources always the answer? A supply and demand analysis for public health services in Brazilian municipalities

    Directory of Open Access Journals (Sweden)

    Fabiana Rocha

    2017-01-01

    Full Text Available The aim of this paper is to determine whether it is necessary to increase available resources to local governments or if better use of these funds is sufficient. The paper contributes to the literature by looking both at the supply and demand for public health services. If the demand is estimated correctly, one can compare its expected value to actual health expenditures. Even if actual expenditures are lower than the estimated demand, it is not certain that additional spending is necessary. If the efficiency scores (supply side indicate that local governments can simply “save” resources to make up for the difference, then it is possible to reduce (or bring to zero new resources only by requiring local governments to efficiently manage their expenditures. Since municipalities in Brazil are very heterogeneous, we estimate their efficiency using the metafrontier approach (O’Donnell et al., 2008, while we estimate the demand through an equation derived from the median voter theorem model. Using 2010 data, we find evidence that efficient management of spending is sufficient to meet excess demand for goods and services in the health sector.

  12. Local climate activities in co-operation between municipality, civil society and science shop

    DEFF Research Database (Denmark)

    Jørgensen, Michael Søgaard

    The Science Shop at DTU co-operates with the local municipal administration and the local branch of an environmental NGO about climate change. The co-operation was initiated by a proposal to the Science Shop from the municipal administration. Since the Science Shop requests civil society...... involvement in projects it was proposed to involve the local branch of the environmental NGO. The starting point was topics developed by the administration and the NGO together and announced to students as part of the Science Shop project supply. The focus is climate impact of local activities and strategies...... are initiated and co-ordinated by a group with members from municipal administration, the local NGO and the Science Shop. All projects have involved student projects, but most projects have also contributed to ongoing research activities. The projects up till now have focused on the municipal food supply...

  13. Design of helium-gas supplying facility of out-of-pile demonstration test for HTTR heat utilization system

    Energy Technology Data Exchange (ETDEWEB)

    Hino, Ryutaro; Fujisaki, Katsuo; Kobayashi, Toshiaki [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    1996-09-01

    One of the objectives of the High-Temperature Engineering Test Reactor (HTTR) is to demonstrate effectiveness of high-temperature heat utilization. Prior to connect a heat utilization system to the HTTR, a series of out-of-pile demonstration test is indispensable to improve components` performance, to demonstrate operation, control and safety technologies and to verify analysis codes for design and safety evaluation. After critical review and discussion on the out-of-pile demonstration test, a test facility have been designed. In this report, a helium-gas supplying facility simulated the HTTR system was described in detail, which supplies High-temperature helium-gas of 900degC to a steam reforming facility mocking-up the HTTR heat utilization system. Components of the Helium Engineering Demonstration Loop (HENDEL) were selected to reuse in the helium-gas supplying facility in order to decrease construction cost. Structures and specifications of new components such as a high-temperature heater and a preheater were decided after evaluation of thermal and hydraulic performance and strength. (author)

  14. Influence of different technologies on dynamic pricing in district heating systems: Comparative case studies

    DEFF Research Database (Denmark)

    Dominkovic, Dominik Franjo; Wahlroos, Mikko; Syri, Sanna

    2018-01-01

    District heating markets are often dominated by monopolies in both Denmark and Finland. The same companies, often owned by local municipalities, are usually operating both supplying plants and district heating networks, while the pricing mechanisms are rigid, often agreed upon for one year...... in advance. The mentioned ownership scheme may cause problems, when one tries to gain a third party access in order to deliver excess heat or heat from cheaper heating plants. In this paper, two case studies were carried out to simulate the district heating systems based on dynamic pricing. Case studies were...... carried out for Sønderborg, Denmark and Espoo, Finland. The results showed that dynamic pricing fosters feeding the waste heat into the grid, as dynamic pricing reduced the total primary energy consumption and CO2 emissions in both case studies. In the best scenarios, the weighted average heat price...

  15. Setting technical and economic features regarding nuclear heating plants implementation for heat supply in Romania by the year 2010

    International Nuclear Information System (INIS)

    Romascu, G.; Constantin, L.; Gheorghe, A.; Ciocanescu, M.; Ionescu, M.

    2008-01-01

    This paper presents the world wide preoccupation concerning the implementation of nuclear heating plants for fulfilling the heat demand and the main technical data of the reactors destined to such NHP's. The second part of this paper shows technical and economic aspects related to the implementation of NHP's equipped with nuclear thermal reactor specialized in the exclusive heat supply in Romania at the level of the year 2010. Among these aspects the following are mentioned: - the results of researches and the world wide achievements; - the development and structure of the production and of the thermal electric energy as well as the feasibility for covering the demands for nuclear sources; - the impact on environment of various technologies for the production of thermal energy with conventional fuels comparing with NHP; - the philosophy from economic stand point for the covering part of the NHP heat demand. (authors)

  16. Health improvement of domestic hot tap water supply Gusev, Kaliningrad Region, Russia. Make-up water tank project. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Aagaard, Joergen

    1998-07-01

    This report describes the project `Health Improvement of Domestic Hot Tap Water Supply, Gusev, Kaliningrad, Russia`, which was carried out in the autumn of 1996 and financed by the Danish Environmental Protection Agency, the Danish Energy Agency and Gusev Municipality. The project proposal and application outlined the following objectives: Erection of system so that hot tap water, which is tapped directly from the district heating system, obtains an acceptable quality in health terms; Complete training and education, so that the plant can be operated and maintained by the power station`s staff and rehabilitation projects within supply of domestic water and district heating can be promoted to the greatest possible extent; Systems for heat treatment of make-up water were implemented in less than three months; The project was carried out in close Danish-Russian co-operation from the beginning of engineering to the commissioning and resulted in transfer and demonstration of know-how and technology; Information was recorded on the existing domestic water and heat supply systems as well as on the treatment of sewage, and recommendations for rehabilitation projects were made. Previously, when the temperature in the district heating system was relatively high, a heat treatment apparently took place in the district heating system. However, due to the current poor economic situation there are no means with which to buy the fuel quantities necessary to maintain the previously normal district heating temperature. In the new concept the cold make-up water is heated to >80 deg. C as required by the health authorities before it is led to the district heating return system and subsequently heated to the actual supply temperature of 50-60 deg. C. The energy consumption in the two concepts is approximately the same. A 1,000 m{sup 3} tank with heating coils was erected between the make-up water system and the district heating system. The tank should equalise the daily capacity

  17. European municipalities and the liberalized energy market

    International Nuclear Information System (INIS)

    2002-04-01

    Municipalities are directly affected by the liberalization of the energy markets. Because they all consume or even produce energy, whether it be for their own consumption or to resell it, they often distribute gas, electricity or heat, they plan urban areas and organize the energy networks on their territory, while in addition citizens expect municipalities to inform them and even protect them against the possible excesses of energy salesmen. Elected representatives administrations, local agencies, municipal companies, citizens' associations etc., all have to innovate. This supplement to Energie-Cites INFO is intended to provide you with practical information and further analyses of the liberalization process. (authors)

  18. Methods for assessing the sustainability of integrated municipal waste management and energy supply systems

    Energy Technology Data Exchange (ETDEWEB)

    Luoranen, M.

    2009-07-01

    The general striving to bring down the number of municipal landfills and to increase the reuse and recycling of waste-derived materials across the EU supports the debates concerning the feasibility and rationality of waste management systems. Substantial decrease in the volume and mass of landfill-disposed waste flows can be achieved by directing suitable waste fractions to energy recovery. Global fossil energy supplies are becoming more and more valuable and expensive energy sources for the mankind, and efforts to save fossil fuels have been made. Waste-derived fuels offer one potential partial solution to two different problems. First, waste that cannot be feasibly re-used or recycled is utilized in the energy conversion process according to EU's Waste Hierarchy. Second, fossil fuels can be saved for other purposes than energy, mainly as transport fuels. This thesis presents the principles of assessing the most sustainable system solution for an integrated municipal waste management and energy system. The assessment process includes: Formation of a SISMan (Simple Integrated System Management) model of an integrated system including mass, energy and financial flows, and formation of a MEFLO (Mass, Energy, Financial, Legislational, Other decisionsupport data) decision matrix according to the selected decision criteria, including essential and optional decision criteria. The methods are described and theoretical examples of the utilization of the methods are presented in the thesis. The assessment process involves the selection of different system alternatives (process alternatives for treatment of different waste fractions) and comparison between the alternatives. The first of the two novelty values of the utilization of the presented methods is the perspective selected for the formation of the SISMan model. Normally waste management and energy systems are operated separately according to the targets and principles set for each system. In the thesis the waste

  19. Is Swedish district heating operating on an integrated market? – Differences in pricing, price convergence, and marketing strategy between public and private district heating companies

    International Nuclear Information System (INIS)

    Åberg, M.; Fälting, L.; Forssell, A.

    2016-01-01

    The deregulation of the Swedish electricity market in 1996 made it possible to operate municipal district heating commercially. Until that time district heating had been organized mainly as municipal utilities. After 1996 district heating is instead expected to function on a market. In competitive and integrated markets, prices are expected to be equal, or converging. To find out if district heating operates on an integrated market the differences in price levels, price convergence, price strategy, and business goals, among municipal, private and state owned district heating companies are investigated. Price statistics was used along with results from a questionnaire that was answered by representatives for 109 Swedish district heating companies. The results show that prices among district heating systems do not converge significantly and that variations in prices among municipal systems are larger than among private and state owned systems. Furthermore, despite the fact that district heating is supposed to be commercial, a vast majority of district heating companies apply cost-based pricing and not market pricing. The municipal companies give priority to political goals before financial goals. The conclusion is that a Swedish integrated market for heat has not yet evolved, and some district heating price-controlling mechanism is necessary. - Highlights: • Price statistics and owner type data were used along with results from a questionnaire. • Results show that prices among district heating systems do not converge. • Municipal district heating companies still apply cost-based pricing to a large extent. • District heating companies are not operating on an integrated market for heat. • Some price-controlling mechanism for district heating is necessary.

  20. Study of an electrical heating system with ductless air supply and shape-stabilized PCM for thermal storage

    International Nuclear Information System (INIS)

    Lin, Kunping; Zhang, Yinping; Di, Hongfa; Yang, Rui

    2007-01-01

    A kind of electrical floor heating system with a shape-stabilized phase change material (PCM) which has been studied at Tsinghua University in our previous studies, can provide space heating during the whole day and can be controlled conventionally. However, this is not suitable for office buildings where no space heating is needed at night. The effective control is very important for the heating system in such buildings. In this paper, we studied a kind of new electrical floor heating system with ductless air supply and shape-stabilized PCM for thermal storage in order to overcome the shortcomings of the passive under-floor electric heating system with thermal storage. In this paper, we investigated its thermal performance by experiments and simulation, calculated the effects of various factors and discussed the application feasibility in different climate regions. The results show that the total electrical energy consumption was shifted from the peak period to the off-peak period, which would provide significant economic benefits because of the different day and night electricity tariffs. The system can be designed by choosing PCM with proper melting temperature and be controlled by varying velocity of air supply in different conditions

  1. Energy, economy and exergy evaluations of the solutions for supplying domestic hot water from low-temperature district heating in Denmark

    International Nuclear Information System (INIS)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    Highlights: • Provided domestic hot water configurations for low-temperature district heating. • Various building typologies and district heating supply temperatures were included. • Different scenarios were evaluated from the energy, economy and exergy aspects. • The benefits of lower return temperature to district heating were investigated. - Abstract: District heating in Denmark is going through the transition from 3rd generation (80/40 °C) to 4th generation (50–55 °C/25 °C) systems in preparation for district heating based completely on renewable fuels by 2035. However, concern about Legionella growth and reduced comfort with low-temperature domestic hot water supply may be discouraging the implementation of low-temperature district heating. Aimed at providing possible solutions, this study modelled various proposals for district heating systems with supply temperatures of 65 °C, 50 °C and 35 °C and for two different building topologies. Evaluation models were built to investigate the energy, economy and exergy performances of the proposed domestic hot water systems in various configurations. The configurations of the devised domestic hot water substations were optimised to fit well with both low and ultra-low-temperature district heating and to reduce the return temperature to district heating. The benefits of lower return temperatures were also analysed compared with the current district heating situation. The evaluation results show that the decentralized substation system with instantaneous heat exchanger unit performed better under the 65 °C and 50 °C district heating scenarios, while the individual micro tank solution consumed less energy and cost less in the 35 °C district heating scenario.

  2. Fuel Application Efficiency in Ideal Cycle of Gas Turbine Plant with Isobaric Heat Supply

    Directory of Open Access Journals (Sweden)

    A. P. Nesenchuk

    2013-01-01

    Full Text Available The paper reveals expediency to use in prospect fuels with maximum value  Qнр∑Vi and minimum theoretical burning temperature in order to obtain maximum efficiency of the ideal cycle in GTP with isobaric heat supply.

  3. Characteristic performance of radio-frequency(RF) plasma heating using inverter RF power supplies

    International Nuclear Information System (INIS)

    Imai, Takahiro; Uesugi, Yoshihiko; Takamura, Shuichi; Sawada, Hiroyuki; Hattori, Norifumi

    2000-01-01

    High heat flux plasma are produced by high powe (∼14 kW) ICRF heating using inverter power supplies in the linear divertor simulator NAGDIS-II. The power flow of radiated rf power is investigated by a calorimetric method. Conventional power calculation using antenna voltage and current gives that about 70% of the rf power is radiated into the plasma. But increase of the heat load at the target and anode is about 10% of the rf power. Through this experiment, we find that about half of the rf power is lost at the antenna surface through the formation of rf induced sheath. And about 30% of the power is lost into the vacuum vessel through the charge exchange and elastic collision of ions with neutrals. (author)

  4. District heating rehabilitation project. Viljandi - Estonia. Final report

    International Nuclear Information System (INIS)

    1998-04-01

    The main objective of the project has been to assist Viljandi Municipality with the rehabilitation of their district heating system, and thereby to support the positive development of the district heating system in Viljandi to a more energy efficient and rational system and to achieve a significantly decrease in the pollution from the production of heat energy in Viljandi. The project has also included technical assistance to Viljandi DH company, in order to make them capable of operation and maintaining of the new substations, and also training of the local operational staff for operation of the complete district heating system. Viljandi is a county and is centrally located in Estonia, which makes Viljandi very suitable as recipient for a demonstration project. One important objective was the projects significantly positive environmental impact in reduction of the generated emissions of CO 2 , NO x and SO 2 , as the project includes installation of more efficient energy systems and supply of heat from the 2 existing district heating plants (both are partly fired with wood chips) instead of heating by very old and worn-out coal fired boilers and inexpedient designed substations with the present operational conditions. (EG)

  5. District heating rehabilitation project. Viljandi - Estonia. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    The main objective of the project has been to assist Viljandi Municipality with the rehabilitation of their district heating system, and thereby to support the positive development of the district heating system in Viljandi to a more energy efficient and rational system and to achieve a significantly decrease in the pollution from the production of heat energy in Viljandi. The project has also included technical assistance to Viljandi DH company, in order to make them capable of operation and maintaining of the new substations, and also training of the local operational staff for operation of the complete district heating system. Viljandi is a county and is centrally located in Estonia, which makes Viljandi very suitable as recipient for a demonstration project. One important objective was the projects significantly positive environmental impact in reduction of the generated emissions of CO{sub 2}, NO{sub x} and SO{sub 2}, as the project includes installation of more efficient energy systems and supply of heat from the 2 existing district heating plants (both are partly fired with wood chips) instead of heating by very old and worn-out coal fired boilers and inexpedient designed substations with the present operational conditions. (EG)

  6. Electricity and heat supply of a settlement at different standards of energy efficiency; Strom- und Waermeversorgung einer Siedlung bei unterschiedlichen Energieeffizienz-Standards

    Energy Technology Data Exchange (ETDEWEB)

    Schuberth, Jens; Tschetschorke, Katja

    2013-07-15

    The underlying study analyses the ecologic impact and the economic efficiency of several conventional and innovative heat supply systems to provide a quarter heat for space and water heating and electricity for residential and commercial application and for street lighting. Retrofits of buildings change the ratio of demands for electricity and heat. The demand for heat decreases more than the demand for electricity, and the share of distribution losses in heat grids rises. The question is if it is still economically efficient to build or extend local and long-distance district heating networks. Demands for final and primary energy, greenhouse gas emissions and costs (for operation, energy consumption and investments) of the different systems are compared and rated both in charts and tables. A sensitivity analysis includes increasing energy purchasing costs and assesses the possible economic efficiency of the supply systems in future. Another sensitivity analysis estimates how the climate impact of the supply systems for heat and electricity changes if electricity generation becomes less harmful for climate. Additionally, costs for environmental damage - so-called external costs - are internalised in the analysis of economic efficiency. In an overall rating ecologic and economically efficient systems are recommended.

  7. 100% energy supply coverage with renewable energy. Requirements for its implementation at the global, national and municipal level

    International Nuclear Information System (INIS)

    Rogall, Holger

    2014-01-01

    This book presents itself as a systematic, easily understandable introduction into the requirements for an energy supply based 100% on renewable energy. Its main focus is on the strategic paths that must be followed for this purpose in the realms of business, technology and governmental policy. It highlights the opportunities and impediments on the way, analysing in the process the roles of political, economic and civil society players from the global down to the municipal level. Starting out from the present state of discussion on the German energy transition it investigates the strengths and weak points of efficiency technologies and renewable energies available today and elaborates a strategic path for developing the necessary infrastructure. In awareness of the fact that 100% coverage will not come about from market mechanisms alone it explores the ecological crash barriers that need to be set up in addition. This is followed by chapters on the roles, interests and means of those players who can exert influence on the framing of the relevant political and legal instruments as well as their means of pursuing their interests. The book thus contributes to clarifying the possibilities of and impediments to achieving an energy supply system based 100% on renewable energy.

  8. Using System Dynamics to Explore the Water Supply and Demand Dilemmas of a Small South African Municipality

    NARCIS (Netherlands)

    Clifford Holmes, J.K.; Slinger, J.H.; Musango, J.K.; Brent, A.C.; Palmer, C.G.

    2014-01-01

    This paper explores the challenges faced by small municipalities in providing water services in a developing-world context of increasing urban demand. The paper uses a case study of the Sundays River Valley Municipality (SRVM) in South Africa. The municipality faces multiple dilemmas in reconciling

  9. Heat supply systems using natural gas in the residential sector: The case of the agglomeration of Seoul

    International Nuclear Information System (INIS)

    Park, Hi-Chun; Kim, Hoseok

    2008-01-01

    Combined heat and power (CHP) and district heating (DH) promotion policies are based on the assumption of high energy efficiencies. In the last two decades, however, there has been a big increase in energy efficiencies of combined-cycle gas power plants (CCs) including CHPs and gas-condensing boilers. This study tries to verify the validity of the assumption of high energy efficiency of DH. The experience in the agglomeration of Seoul shows that DH in combination with large modern CHPs is not more energy efficient but substantially more expensive compared to individual gas heating by efficient condensing boilers in combination with CCs. We argue that the Korean government should review its CHP/DH support programs and abandon the so-called heat supply monopoly for DH operators in newly developed residential areas. Such a policy intervention only distorts the space heating market and wastes valuable financial resources. Furthermore, the public should be properly informed on energy efficiency as well as energy- and system-related costs of various heat supply systems. In the light of the present improvements in the performance of gas-condensing boilers and CCs, the validity of the assumption of high energy efficiency of CHP/DH in other countries has to be reviewed

  10. Comparison of ANN (MLP), ANFIS, SVM, and RF models for the online classification of heating value of burning municipal solid waste in circulating fluidized bed incinerators.

    Science.gov (United States)

    You, Haihui; Ma, Zengyi; Tang, Yijun; Wang, Yuelan; Yan, Jianhua; Ni, Mingjiang; Cen, Kefa; Huang, Qunxing

    2017-10-01

    The heating values, particularly lower heating values of burning municipal solid waste are critically important parameters in operating circulating fluidized bed incineration systems. However, the heating values change widely and frequently, while there is no reliable real-time instrument to measure heating values in the process of incinerating municipal solid waste. A rapid, cost-effective, and comparative methodology was proposed to evaluate the heating values of burning MSW online based on prior knowledge, expert experience, and data-mining techniques. First, selecting the input variables of the model by analyzing the operational mechanism of circulating fluidized bed incinerators, and the corresponding heating value was classified into one of nine fuzzy expressions according to expert advice. Development of prediction models by employing four different nonlinear models was undertaken, including a multilayer perceptron neural network, a support vector machine, an adaptive neuro-fuzzy inference system, and a random forest; a series of optimization schemes were implemented simultaneously in order to improve the performance of each model. Finally, a comprehensive comparison study was carried out to evaluate the performance of the models. Results indicate that the adaptive neuro-fuzzy inference system model outperforms the other three models, with the random forest model performing second-best, and the multilayer perceptron model performing at the worst level. A model with sufficient accuracy would contribute adequately to the control of circulating fluidized bed incinerator operation and provide reliable heating value signals for an automatic combustion control system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Dual-purpose light water reactor supplying heat for desalination

    International Nuclear Information System (INIS)

    Waplington, G.; Fichtner, H.

    1978-01-01

    The technical as well as the economic aspects of using a large commercial light water reactor for the production of both electricity and potable water have been examined. For the basis of the study, the multistage flash distillation process was selected, in conjunction with a reactor rated at not less than 2100 MW (thermal). Combined use of a condensing and a back-pressure turbine (the latter matched to distillation plant steam requirements) represents a convenient method for supplying process heat. Overall costs can be fairly allocated to the two products using the ''power credit'' method. A sample economic evaluation indicates highly favorable water costs as compared with more conventional distillation schemes based on fossil fuel

  12. 77 FR 61595 - Northern Illinois Municipal Power; Notice of Filing

    Science.gov (United States)

    2012-10-10

    ... Illinois Municipal Power filed its Revised and Superseding Proposed Revenue Requirement for reactive supply... Reference Room in Washington, DC. There is an ``eSubscription'' link on the web site that enables...

  13. The Polyvalent Heat Supply System for Experimental Building of the Passive Type (area of 300 m2 Based on Renewable and Alternative Energy Sources

    Directory of Open Access Journals (Sweden)

    Basok, B.I.

    2014-11-01

    Full Text Available Results of the development and implementation of heat supply system for experimental building of the passive type are presented, optimal operating conditions are investigated, guidelines for the creation of heat supply systems for passive type buildings are provided.

  14. Research challenges in municipal solid waste logistics management.

    Science.gov (United States)

    Bing, Xiaoyun; Bloemhof, Jacqueline M; Ramos, Tania Rodrigues Pereira; Barbosa-Povoa, Ana Paula; Wong, Chee Yew; van der Vorst, Jack G A J

    2016-02-01

    During the last two decades, EU legislation has put increasing pressure on member countries to achieve specified recycling targets for municipal household waste. These targets can be obtained in various ways choosing collection methods, separation methods, decentral or central logistic systems, etc. This paper compares municipal solid waste (MSW) management practices in various EU countries to identify the characteristics and key issues from a waste management and reverse logistics point of view. Further, we investigate literature on modelling municipal solid waste logistics in general. Comparing issues addressed in literature with the identified issues in practice result in a research agenda for modelling municipal solid waste logistics in Europe. We conclude that waste recycling is a multi-disciplinary problem that needs to be considered at different decision levels simultaneously. A holistic view and taking into account the characteristics of different waste types are necessary when modelling a reverse supply chain for MSW recycling. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Some aspects of radioprotection assurance in radiodiagnostic service activity from Chisinau municipality in 2006-2007

    International Nuclear Information System (INIS)

    Rosca, A.; Stanchevici, V.; Balanel, V.; Danga, V.

    2007-01-01

    Together with the accordance of specialized medical assistance, the population of Chisinau municipality needs the accordance of general radiodiagnostic and interventional qualitative assistance. The permanent multi-institutional supervision offers partial optimization of radioprotection in the Republic Medical and Sanitary Institutions (PMSI) of Chisinau municipality. The qualitative optimization of radioprotection in PMSI of Chisinau municipality can be assured while being supplied with the operation radio diagnostic equipment. (authors)

  16. The prospects for nuclear heating in Hungary

    International Nuclear Information System (INIS)

    Lynch, G.F.; Papp, I.

    1989-09-01

    Hungary supplies only half of its energy requirements from domestic resources and is very dependent upon imports of oil, natural gas and electricity to meet the current demand. In planning to reduce the dependence on imports, nuclear technology is considered an important element in the long-term energy strategy. To this end, an aggressive nuclear electricity generation program is being implemented with four 440 MWe units now operating and two 1000 MWe units committed. However, nuclear technology must be used in other energy sectors if the goal of long-term energy independence is to be achieved. On the demand side, 30% of the primary energy is consumed in the public sector, the major component being residential heating. Of the 3.7 million apartments in Hungary, 500 000 benefit from being connected to municipal district heating systems that use natural gas or oil as the energy base. This is, therefore, another significant energy sector that is amenable to using nuclear technology to substitute for imported oil and natural gas. In assessing alternative nuclear heat sources, a joint study was undertaken between Canada and Hungary to determine the feasibility of using the SLOWPOKE Energy System that has recently been developed. The SLOWPOKE Energy System is a benign nuclear heat source designed to supply 10 thermal megawatts in the form of hot water for local heating systems in buildings and institutions. It uses a combination of inherent safety features, including natural convection circulation and negative reactivity coefficients, and engineered features to ensure an extremely safe system. A SLOWPOKE demonstration heating reactor has been constructed in Canada. The unit started operation in 1987 July and is currently undergoing an extensive test program

  17. Municipal hydraulic planning for energy saving; Planeacion hidraulica municipal para el ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Garcia, Enrique [PTF S.C. Consultores, Leon, Gto. (Mexico)

    1999-07-01

    The efficient handling of the economic and natural resources of the municipalities, is nowadays so much complex, that it requires a formal planning. In the public service of potable water supply, two fundamental approaches are conjugated to consider: the rational use of the water resource and the efficient use of the electrical energy, for its extraction from the underground deep reservoirs. In the paper that is presented, the individual features of the previous matters are described and the positive results in a municipality of the Guanajuato's Low Lands (Bajio ), where already the dual objectives are obtained and that with a more professional municipal hydraulic planning, these will be permanent, with the inherent benefit towards the population. [Spanish] El manejo eficiente de los recursos economicos y naturales de los municipios, es hoy en dia cada vez mas complejo, que requiere una planeacion formal. En el servicio publico de abastecimiento de agua potable, se conjugan dos enfoques primordiales a considerar: el uso racional del recurso agua y la utilizacion eficiente de la energia electrica, para su extraccion de los acuiferos subterraneos profundos. En el trabajo que se presenta, se describen las particularidades de lo anterior y los resultados positivos en un municipio del Bajio guanajuatense, donde ya se logran los objetivos duales y que con una planeacion hidraulica municipal mas profesional, estos seran permanentes, con el beneficio inherente hacia la poblacion.

  18. 76 FR 55449 - Self-Regulatory Organizations; Municipal Securities Rulemaking Board; Notice of Filing of...

    Science.gov (United States)

    2011-09-07

    ... purchasing of supplies. SIFMA noted that it understood why the wording of the gift prohibition for municipal... the Municipal Securities Rulemaking Board Consisting of Amendments to MSRB Rule G-20 (Gifts and... Commission a proposed rule change consisting of proposed amendments to MSRB Rule G-20 (on gifts and...

  19. Development of two-stage compression heat pump for hot water supply in commercial use. Establishment of design method for water and air heat source system; Gyomuyo nidan asshukushiki kyuto heat pump no kaihatsu. Suinetguen oyobi kuki netsugen sytem no sekkei hoho no kakuritsu

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, H; Hashimoto, K; Saikawa, M; Iwatsubo, T; Mimaki, T [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1996-07-01

    The two-stage compression cascade heating heat pump cycle was devised for hot water supply in business use such as hotel and store use which allows hot water supply less in primary energy consumption than gas boilers, and higher in temperature than conventional heat pumps. This cycle heats water in cascade manner by two-stage compression using two compressors in both low- and high-stage refrigerant circuits, and two condensers different in condensation temperature (intermediate heat exchanger and condenser) to achieve higher hot water temperature and higher COP. For cost reduction, the new system design method was established which is possible to cope with conventional compressors such as screw and scroll ones with different theoretical suction volume for every one. System design parameters such as thermal output and COP of hot water supply were largely affected by theoretical suction volume ratio of low- and high-stage compressors dependent on combination of the compressors, and refrigerant condensing temperature in an intermediate heat exchanger as proper parameter. 4 refs., 17 figs., 13 tabs.

  20. MAPPING ECOSYSTEM SERVICES SUPPLY IN MOUNTAIN REGIONS: A CASE STUDY FROM SOUTH TYROL (ITALY

    Directory of Open Access Journals (Sweden)

    U. Schirpke

    2014-04-01

    Full Text Available Mountain regions provide many ecosystem services and spatially explicit assessments have to account for their specific topographic and climatic conditions. Moreover, it is fundamental to understand synergies and trade-offs of multiple ecosystem services. In this study, ecosystem services supply, including forage production, timber production, water supply, carbon sequestration, soil stability, soil quality, and the aesthetic value, was quantified in bio-physical terms on the landscape scale for South Tyrol. Mean ecosystem services values of the 116 municipalities were grouped in 5 clusters. The results indicate that carbon stock is the prevailing ecosystem service of valley municipalities. On contrast, they suffer from water deficit and depend on water supply from high mountain municipalities. Trade-offs can be also found between the aesthetic value on one hand and timber production, carbon sequestration and soil stability on the other hand. The latter are characteristic for municipalities dominated by forest. The resulting maps can support landscape planning, ecosystem management and conservation of biodiversity.

  1. On the way towards smart energy supply in cities: The impact of interconnecting geographically distributed district heating grids on the energy system

    DEFF Research Database (Denmark)

    Dominkovic, D. F.; Bačeković, I.; Sveinbjörnsson, D.

    2017-01-01

    assessed. Moreover, the impact of industrial waste heat on the DH supply was also assessed. In the reference year (2013) two out of four interconnections proved to be economically viable. The results for the future energy system (2029) showed that interconnecting geographically distributed DH grids reduces...... of the future energy supply system with interconnected DH grids and installed industrial waste heat recuperation results in the lowest primary energy demand, emissions and costs. Finally, the benefits of the interconnected DH grid, in terms of system flexibility, CO2 emissions, total costs and energy efficiency...... primary energy supply by 9.5%, CO2 emissions by 11.1% and total system costs by 6.3%. Inclusion of industrial waste heat in the fully interconnected DH grid reduced primary energy supply for an additional 3%, CO2 emissions for an additional 2.2% and total system costs for an additional 1.3%. The case...

  2. Feasibility improvement project of a district heat supply system in Dalian, China

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Investigations and discussions have been given on energy saving possibilities at two medium-sized heat and power supplying plants in the city of Dalian in China. The project will improve the operation methods of the heat and power plants so that the energy cost can be minimized, and attempt to improve the boiler heat efficiency and save the energy by means of heat recovery and utilization. The draft modification plan for energy conservation has planned operation optimization for energy conservation, control of boiler operation under variable pressure, modification of the external boiler heat converter, use of inverters for the large capacity motors for boilers, and recovery of heat from the boiler blow-down water. In the analysis, models were structured from the operation data, and the effects of applying the energy saving measures were derived from simulation. As a result, the energy saving effect was found to be about 13,000 tons at the Chunhai plant and about 7,000 tons at the Pulandian plant annually (converted to oil). The reduction in greenhouse gas emission was found to be about 40,000 tons at the Chunhai plant and about 20,000 tons at the Pulandian plant annually. The number of years for investment payback is about 4.1 years at the Chunhai plant, and about 4.9 years at the Pulandian plant, wherein good profitability can be estimated. (NEDO)

  3. Energy, economy and exergy evaluations of the solutions for supplying domestic hot water from low-temperature district heating in Denmark

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    District heating in Denmark is going through the transition from 3rd generation (80/40 °C) to 4th generation (50-55 °C/25 °C) systems in,preparation for district heating based completely on renewable fuels by 2035. However, concern about Legionella growth and reduced comfort with low......-temperature domestic hot water supply may be discouraging the implementation of low-temperature district heating. Aimed at providing possible solutions, this study modelled various proposals for district heating systems with supply temperatures of 65 °C, 50 °C and 35 °C and for two different building topologies....... Evaluation models were built to investigate the energy, economy and exergy performances of the proposed domestic hot water systems in various configurations. The configurations of the devised domestic hot water substations were optimised to fit well with both low and ultra-low-temperature district heating...

  4. Burnout in a high heat flux boiling system with forced supply of liquid through a plane jet

    International Nuclear Information System (INIS)

    Katto, Yoshiro; Ishii, Kazunori.

    1978-01-01

    As for pool boiling, the non-dimensional formula for the burnout heat flux of a simple, basic boiling system has been obtained. On the other hand, in forced convection boiling, the studies on the burnout in forced flow boiling in a channel have been continued, but the derivation of a non-dimensional formula applicable generally is far away from the realization because the phenomena are too complex. Accordingly, in this study, the result of the experiment on the burnout of a boiling system to which liquid is supplied by the plane jet flowing out of a thin rectangular nozzle installed near the front edge of a rectangular heating surface is reported. The experimental apparatus is described, and the experiment was carried out in the ranges of two jet thicknesses at the nozzle outlet, two incident angles of jet and from 1.5 to 15 m/s of jet velocity. Burnout occurs under the situation of sufficiently developed nuclear boiling. A part of the liquid supplied from a plane jet is blown apart by the vapor blowing out of the nuclear boiling liquid layer covering the heating surface in the nuclear boiling with sufficiently developed high heat flux. However, the nuclear boiling liquid layer itself continues to exist on the heating surface till burnout occurs. Only the entering velocity of the plane jet affects burnout heat flux. (Kako, I.)

  5. Heat planning for fossil-fuel-free district heating areas with extensive end-use heat savings

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, S.

    2014-01-01

    is a theoretical investigation of the district heating system in the Copenhagen area, in which heat conservation is related to the heat supply in buildings from an economic perspective. Supplying the existing building stock from low-temperature energy resources, e.g. geothermal heat, might lead to oversized......The Danish government plans to make the Danish energy system to be completely free of fossil fuels by 2050 and that by 2035 the energy supply for buildings and electricity should be entirely based on renewable energy sources. To become independent from fossil fuels, it is necessary to reduce...... the energy consumption of the existing building stock, increase energy efficiency, and convert the present heat supply from fossil fuels to renewable energy sources. District heating is a sustainable way of providing space heating and domestic hot water to buildings in densely populated areas. This paper...

  6. What is the future potential for imports of combustible municipal waste to countries with extensive district heating hetworks? - A case study of Denmark

    DEFF Research Database (Denmark)

    Pizarro, Amalia Rosa; Münster, Marie; Salvucci, Raffaele

    2015-01-01

    In Europe landfilling is the most widely used method for managing municipal solid waste. By constrart, the northern European waste market is characterized by high capacities from energy recovery plants, mostly incineration in cogeneration facilities. In Denmark, there is an overcapacity of incine...... are described through linking of mathematical models, taking a holistic approach. In the short-term it pays off to import waste, avoiding landfilling; however, in the longer-term, benefits from waste trading will depend on the price of heat markets.......In Europe landfilling is the most widely used method for managing municipal solid waste. By constrart, the northern European waste market is characterized by high capacities from energy recovery plants, mostly incineration in cogeneration facilities. In Denmark, there is an overcapacity...

  7. Drinking water quality of Sukkur municipal corporation

    International Nuclear Information System (INIS)

    Kandhar, I.A.; Ansari, A.K.

    2002-01-01

    SMC (Sukkur Municipal Corporation) supply the (filtered/settled) water for domestic purpose to the consumers, through intermittent water supply, from Phases I to IV. The water supply distribution network is underground and at most places pass parallel to sewerage lines. The grab sampling technique was followed for collecting representative samples. The official US-EPA and standard methods of water analysis have been used for drinking water quality analysis. DR/2000 spectrophotometer has been used for monitoring: Nitrates, Fluorides, Sulfates, Copper, Chromium, Iron and manganese. The trace metals Cr/sup 6/, Fe/sup 2+/ and other contaminants like; Turbidity and TSS (Total Suspended Solids) have been found higher than World Health Organization (WHO-1993) guideline values. (author)

  8. Modeling the Mixing of Components in a Rotary Kiln While Burning Municipal Waste to Ensure Rational Use of Energy

    Directory of Open Access Journals (Sweden)

    Krot O.P.

    2017-08-01

    Full Text Available In Ukraine municipal waste is collected and delivered to a landfill. Municipal waste can be used as fuel to generate additional heat and electricity. The primary advantages of incineration are that waste volumes are reduced by an estimated, and the need for land and landfill space is greatly reduced. The plant has been designed by North–East Scientific Center using a thermocatalytic waste gas purification system with highly efficient dioxins reduction and heat energy recovery system. The technology of waste neutralization includes: a rotary kiln, an afterburner chamber, a new catalytic technologies for the treatment, a heat exchanger for heating combustion air, supply of alkali solution into the gas-escape channel, a carbon fiber adsorption filter. The organization of the right process of waste mixing in the rotary kiln allows increasing the efficiency of combustion, to equalize the combustion temperatures of the components of the waste and the completeness of the burning out of hazardous substances, which reduces the risk of their getting into the ash. The goal of the research is to build an analytical mathematical model of mixing of components in a rotary kiln. The model is based on the mathematical apparatus of Markov chains. The model allows to determine the concentration of the key component in any elementary volume of material circulating in the rotary kiln at any time and to calculate the statistical characteristics of the homogeneity of the mixture. The model will be used to research new designs of the equipment with rotary kilns.

  9. Energy Supply Modelling in Cities, Illustrated Using Data from the Municipality of Sønderborg in Denmark

    DEFF Research Database (Denmark)

    Sveinbjörnsson, Dadi Þorsteinn; Algren, Loui; Bavnhøj Hansen, Anders

    transmission networks is highest within cities, it is useful to focus on city areas when seeking to optimize the system efficiency, economy and integration. We have performed a case study using data from the Danish municipality of Sønderborg, which has the goal of becoming CO2 neutral by 2029. We have...... of fossil fuels for electricity and heat generation by 2035 and at having a fully renewable energy system by 2050. Harmonized national and regional efforts are required in order to meet these goals. As the majority of the demand for energy services is located in cities, and because the density of energy...... in which gas turbines for reserve electricity generation have been displaced by reversible electrolysis/fuel cell systems. The aim of the case study was to identify if and how new energy conversion technologies can be integrated in the future energy system to meet the demand for energy services...

  10. A pilot-scale steam autoclave system for treating municipal solid waste for recovery of renewable organic content: Operational results and energy usage.

    Science.gov (United States)

    Holtman, Kevin M; Bozzi, David V; Franqui-Villanueva, Diana; Offeman, Richard D; Orts, William J

    2016-05-01

    A pilot-scale (1800 kg per batch capacity) autoclave used in this study reduces municipal solid waste to a debris contaminated pulp product that is efficiently separated into its renewable organic content and non-renewable organic content fractions using a rotary trommel screen. The renewable organic content can be recovered at nearly 90% efficiency and the trommel rejects are also much easier to sort for recovery. This study provides the evaluation of autoclave operation, including mass and energy balances for the purpose of integration into organic diversion systems. Several methods of cooking municipal solid waste were explored from indirect oil heating only, a combination of oil and direct steam during the same cooking cycle, and steam only. Gross energy requirements averaged 1290 kJ kg(-1) material in vessel, including the weight of free water and steam added during heating. On average, steam recovery can recoup 43% of the water added and 30% of the energy, supplying on average 40% of steam requirements for the next cook. Steam recycle from one vessel to the next can reduce gross energy requirements to an average of 790 kJ kg(-1). © The Author(s) 2016.

  11. Solar thermal energy / exhaust air heat pump / wood pellet furnace for a sustainable heat supply of low energy buildings in older buildings; Solarthermie / Abluft-Waermepumpe / Pelletofen. Kombisysteme zur nachhaltigen Waermeversorgung von Niedrigenergiehaeusern im Gebaeudebestand

    Energy Technology Data Exchange (ETDEWEB)

    Diefenbach, Nikolaus; Born, Rolf [Institut Wohnen und Umwelt GmbH, Darmstadt (Germany); Staerz, Norbert [Ingenieurbuero inPlan, Pfungstadt (Germany)

    2009-11-13

    The research project under consideration reports on combination systems for a sustainable heat supply for low-energy buildings in older building. For this, a central and decentralized system configuration consisting of solar thermal energy, exhaust air heat pump and wood pellet furnace are presented. Solutions for an interaction of these three heat suppliers in one plant are designated regarding the control strategy. The fundamentals of the computerized simulations for the central and decentralized system are presented. A cost estimate with both variants of the combination system as well as a comparison with conventional energy-saving heat supply systems follow.

  12. Biomass universal district heating systems

    Science.gov (United States)

    Soltero, Victor Manuel; Rodríguez-Artacho, Salvador; Velázquez, Ramón; Chacartegui, Ricardo

    2017-11-01

    In mild climate regions Directive 27/2012 EU application for developing sustainable district heating networks in consolidated urban nucleus is a challenge. In Spain most of the municipalities above 5,000 inhabitants have a reliable natural gas network and individual heating systems at homes. In this work a new heating network paradigm is proposed, the biomass universal heating network in rural areas. This model involves all the economic, legal and technical aspects and interactions between the different agents of the systems: provider company, individual and collective end-users and local and regional administration. The continental region in Spain has 588 municipalities with a population above 1,500 inhabitants close to forest biomass with renewable use. In many of these cases the regulation identifies the ownership of the forest resources use. The universal heating networks are a great opportunity for energy saving of 2,000 GWh, avoiding 2.7 million tons of CO2 emissions and with a global annual savings for end users of 61.8 million of euros. The presented model is easily extrapolated to other small municipalities in Europe. The real application of the model is presented for three municipalities in different locations of Spain where Universal Heating Networks are under development. The analysis show the interest of the integrated model for the three cases with different structural agents and relationships between them. The use of sustainable forest resources, extracted and managed by local companies, strengths circular economy in the region with a potential global economic impact above 200 M€.

  13. 77 FR 47061 - Northern Illinois Municipal Power Agency; Notice of Filing

    Science.gov (United States)

    2012-08-07

    ... Municipal Power Agency filed a Proposed Revenue Requirement for reactive supply service under Midwest... Reference Room in Washington, DC. There is an ``eSubscription'' link on the web site that enables...

  14. Locally Integrated Energy Sectors supported by renewable network management within municipalities

    International Nuclear Information System (INIS)

    Kostevšek, Anja; Petek, Janez; Čuček, Lidija; Klemeš, Jiří Jaromír; Varbanov, Petar Sabev

    2015-01-01

    The decarbonisation of energy systems is one of the important issues of the present energy policies. One of the ways of achieving this is to focus on local energy systems, thus ensuring as much as possible their heat and power self-sufficiency by applying local renewable resource integration and transformation of the renewable energy. Increasing the share of renewables within the local energy balance could be accomplished by using a variety of approaches. One possibility is combining the Locally Integrated Energy Sectors' concept with the novel management and organisation of a renewables-based network. As a first priority, the proposed comprehensive approach focuses on increasing the energy efficiency of municipal heat and power systems using the Locally Integrated Energy Sectors' concept, which is followed by the integration of renewable energy sources with the establishment of a renewable-based network. The proposed approach is illustrated by a case study of district heating based on wood biomass for the municipality Ormož, Slovenia by integrating various end-users from different sectors. - Highlights: • The paper presents a new approach for accelerated inception of RES in municipalities. • LIES with RES network increases energy efficiency and accelerates RES integration. • A demonstration case of district heating on wood biomass within Ormož was performed.

  15. Energy costs and Portland water supply system

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, W.M.; Hawley, R.P.

    1981-10-01

    The changing role of electrical energy on the Portland, Oregon, municipal-water-supply system is presented. Portland's actions in energy conservation include improved operating procedures, pump modifications, and modifications to the water system to eliminate pumping. Portland is implementing a small hydroelectric project at existing water-supply dams to produce an additional source of power for the area. Special precautions in construction and operation are necessary to protect the high quality of the water supply. 2 references, 7 figures.

  16. Town engineers in South Africa before 1910, with reference to water supply

    Directory of Open Access Journals (Sweden)

    Harri Mäki

    2013-07-01

    Full Text Available This article looks at the town engineers in South Africa prior to Union in 1910. It briefly examines the growth in the number of municipalities and town engineers in the country in this period and investigates the background and training of these engineers; why municipalities decided to appoint an engineer; and what kind of appointment processes were followed. Finally the relations between engineers and town councils and the prevailing circumstances at the end of the engineers’ tenures is studied. The article also presents ten specific cases which have reference to the development of water supply. It emerges that most early town engineers received training via apprenticeship for the positions they held, and that there was added pressure from elected councillors in municipalities who were prone to monitor assiduously how officials were spending public money. It is also clear that engineers who did not have earlier municipal experience were bound to have problems in their interaction with town councillors. Keywords: Municipal history, civil engineering, water supply, sanitation, Cape Colony, Natal, Orange Free State, Transvaal Disciplines: History, Engineering, Public Management

  17. The Forest Energy Chain in Tuscany: Economic Feasibility and Environmental Effects of Two Types of Biomass District Heating Plant

    Directory of Open Access Journals (Sweden)

    Claudio Fagarazzi

    2014-09-01

    Full Text Available The purpose of this study was to examine two biomass district heating plants operating in Tuscany, with a specific focus on the ex-post evaluation of their economic and financial feasibility and of their environmental benefits. The former biomass district heating plant supplies only public users (Comunità Montana della Lunigiana, CML: administrative body that coordinates the municipalities located in mountain areas, the latter supplies both public and private users (Municipality of San Romano in Garfagnana. Ex-post investment analysis was performed to check both the consistency of results with the forecasts made in the stage of the project design and on the factors, which may have reduced or jeopardized the estimated economic performance of the investment (ex-ante assessment. The results of the study point out appreciable results only in the case of biomass district heating plants involving private users and fuelled by biomasses sourced from third parties. In this case, the factors that most influence ex-post results include the conditions of the woody biomass local market (market prices, the policies of energy selling prices to private users and the temporal dynamics of private users’ connection. To ensure the consistency of ex-post economic outcome with the expected results it is thus important to: (i have good knowledge of the woody local market; (ii define energy selling prices that should be cheap for private users but consistent with energy production costs and (iii constrain private users beforehand to prevent errors in the plant design and in the preliminary estimate of return on investment. Moreover, the results obtained during the monitoring activities could help in providing information on the effectiveness of the supporting measures adopted and also to orient future choices of policy makers and particularly designers, to identify the most efficient configuration of district heating organization for improving energy and

  18. Energy supply. Energieversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Eickhof, N.

    1983-01-01

    This anthology presents nine papers dealing with the following subjects: 1) international and national aspects of energy supply, 2) regional and local energy supply concepts, and 3) issues of district-heat supply. Each of the nine papers was entered separately.

  19. The situation of district heating, district cooling and energy supply in Hungary

    International Nuclear Information System (INIS)

    Sigmond, Gy.

    2009-01-01

    District heating represents with 650.000 heated dwellings approximately 15% of the Hungarian residential heating market. Since 1990 there is stagnation at the number of connected dwellings because erection of large settlements with prefab buildings has been stopped, and latter ones represent more than 75% of the dwelling heating market. During the same period, residential heat demand shrunk by 33%, because metering of hot water consumption resulted in changing consumer habits, and because of slowly but step by step refurbishment of buildings and heating systems. In Hungary district heating is present in all large and most of the medium size cities, in 92 cities together. Out of them, there is also a single village with a local district heating system, which heats more than 60% of cottages. The capacity os systems is spreading to a large extent. Approximately 36-36% of all heated dwellings are in Budapest and in 10 large cities in the country, while 148 of the total 202 systems have less than 10 MW capacities. In the fuel structure of district heating it is characteristic the overwhelming role of natural gas consumption, which has exceeded 80% already. Only a few numbers of heating power plants are fuelled by crown coal. The use of renewables is growing continuous, but, together with waste and waste energy, it amounts merely 8% of the total fuel use. Oil consumption is negligible. Currently the most promising DH-market is the service sector (public buildings and commercial consumers). DH-companies can sell their surplus supply capacities on the competitive market. Residential market can be preserved only with better legal conditions and with improving of demand side management. The industrial heat market can be gained when the erection of new power plants will be harmonized with industrial development in the frame of territorial planning. District cooling is just at the beginning in Hungary. Many new commercial and office buildings are erected with air conditioning

  20. Effectiveness of price adjustment clauses in district heat supply contracts. Consequences of the 2011 BGH rulings; Wirksamkeit von Preisanpassungsklauseln in Fernwaermelieferungsvertraegen. Konsequenzen der BGH-Urteile 2011

    Energy Technology Data Exchange (ETDEWEB)

    Buedenbender, Ulrich; Gromm, Marcel [TU Dresden (Germany). Lehrstuhl fuer Buergerliches Recht, Energiewirtschaftsrecht und Arbeitsrecht

    2011-07-01

    In 2011, the BGH had to decide for the first time on price adjustment clauses. There were four court rulings on price adjustment clauses in district heat supply contracts, and price adjustment clauses were considered to be ineffective in all cases. This is a trend similar to the rulings on gas supply contracts since 2005. This contribution discusses the consequences of the 2011 BGH rulings for future price adjustment clauses in district heat supply contracts. The contract partners, especially the customers of district heating utilities, must be sure whether a raised supply price will be based on an effective price adjustment clause, or whether it will enable the customer to refuse payment. (orig.)

  1. Submission of the Federation of Canadian Municipalities to the House of Commons Standing Committee on Environment, Parliament of Canada in respect of the Standing Committee's study on global warming

    International Nuclear Information System (INIS)

    Brown, G.; Gilbert, R.; Goulet, D.

    1990-01-01

    The views of an organization representing Canadian municipalities concerning the effects of global warming and climatic change are presented. Overall concerns include the lack of ready availability of information on future climatic changes and the apparent weak leadership of the federal government with regard to environmental matters. Specific concerns on the direct effects of global warming on municipalities include the effects of flooding and drought on public services, a possible deterioration in water supply and quality, increasing risk of fires, immigration from drought-affected areas of the world, diseases relating to the spread of subtropical plants and animals, and changes in regulations concerning the use of energy and the design of buildings. From the municipal perspective, contributions to the prevention of climatic change would have to come from reducing energy use for transportation, such as encouraging greater use of public transit, and reducing energy use in buildings through improved design and installation of district heating/cooling systems

  2. Proposal for the award of a contract for the supply of bake-out heating jackets for the LHC vacuum components

    CERN Document Server

    2006-01-01

    This document concerns the award of a contract for the supply of bake-out heating jackets for the LHC vacuum components. The Finance Committee is invited to agree to the negotiation of a contract with ELTHERM (DE), the lowest bidder, for the supply of heating jackets for a total amount of 711 567 euros (1 120 646 Swiss francs), not subject to revision, with an option for up to 15% additional heating jackets for an additional amount of up to 106 735 euros (168 097 Swiss francs), not subject to revision, bringing the total amount to 818 302 euros (1 288 743 Swiss francs), not subject to revision. The amounts in Swiss francs have been calculated using the present rate of exchange. 2006/68/5/e

  3. Equipment sizing in a coal-fired municipal heating plant modernisation project with support for renewable energy and cogeneration technologies

    International Nuclear Information System (INIS)

    Kalina, Jacek

    2014-01-01

    Highlights: • Sizing of biomass fired cogeneration block is performed for existing heating plant. • Mathematical model for cogeneration block optimisation is presented. • Impact of financial support mechanisms on optimal solution is discussed. • Influence of short term variations of prices and support intensity is presented. • Different design parameters are suggested by economic and technical quality indices. - Abstract: The paper presents results of design parameters optimisation of a wood chips fired steam boiler based heat and power block in a sample project of coal fired municipal heating plant modernisation. The project assumes the conversion of the heating plant into a dual fuel heat and power plant. The problem that is presented is selection of cogeneration block structure and thermodynamic parameters taking into account financial support mechanisms for cogeneration and renewable energy technologies. There are examined energy conversion and financial performances of the project. The results show that without the financial support the project is not profitable although it generates savings of primary energy of fossil fuels. If an administrative incentives are applied the optimal technical solution is different than suggested by energy conversion efficiency or fossil fuel savings. Financial calculations were performed for Polish marked conditions in the years 2011 and 2014 showing the impact of relatively short term variations of prices and support intensity on optimal plant design parameters

  4. Electricity and combined heat and power from municipal solid waste; theoretically optimal investment decision time and emissions trading implications.

    Science.gov (United States)

    Tolis, Athanasios; Rentizelas, Athanasios; Aravossis, Konstantin; Tatsiopoulos, Ilias

    2010-11-01

    Waste management has become a great social concern for modern societies. Landfill emissions have been identified among the major contributors of global warming and climate changes with significant impact in national economies. The energy industry constitutes an additional greenhouse gas emitter, while at the same time it is characterized by significant costs and uncertain fuel prices. The above implications have triggered different policies and measures worldwide to address the management of municipal solid wastes on the one hand and the impacts from energy production on the other. Emerging methods of energy recovery from waste may address both concerns simultaneously. In this work a comparative study of co-generation investments based on municipal solid waste is presented, focusing on the evolution of their economical performance over time. A real-options algorithm has been adopted investigating different options of energy recovery from waste: incineration, gasification and landfill biogas exploitation. The financial contributors are identified and the impact of greenhouse gas trading is analysed in terms of financial yields, considering landfilling as the baseline scenario. The results indicate an advantage of combined heat and power over solely electricity production. Gasification, has failed in some European installations. Incineration on the other hand, proves to be more attractive than the competing alternatives, mainly due to its higher power production efficiency, lower investment costs and lower emission rates. Although these characteristics may not drastically change over time, either immediate or irreversible investment decisions might be reconsidered under the current selling prices of heat, power and CO(2) allowances.

  5. Status of domestic wastewater management in relation to drinking-water supply in two states of India.

    Science.gov (United States)

    Pandey, R A; Kaul, S N

    2000-01-01

    In India, supply of drinking water, treatment and disposal of domestic wastewater including faecal matter are managed by local bodies. The existing status of water supply, characteristics of domestic wastewater, modes of collection, treatment and disposal system for sewage and faecal matter in 82 municipalities and 4 municipal corporations were assessed in the States of Bihar and West Bengal in India. Domestic wastewater in the municipal areas is collected and discharged through open kachha (earthen), pucca (cement-concrete) and natural drains and discharged into water courses or disposed on land. Scavenger carriage system for night soil disposal is in-vogue at several places in the surveyed States. Open defecation by the inhabitants in some of the municipalities also occurs. The existing methods of collection, treatment and disposal of sewage impairs the water quality of different water sources. Techno-economically viable remedial measures for providing basic amenities, namely safe drinking-water supply and proper sanitation to the communities of these two States of India are suggested and discussed.

  6. 43 CFR 404.3 - What is the Reclamation Rural Water Supply Program?

    Science.gov (United States)

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false What is the Reclamation Rural Water Supply... RECLAMATION, DEPARTMENT OF THE INTERIOR RECLAMATION RURAL WATER SUPPLY PROGRAM Overview § 404.3 What is the Reclamation Rural Water Supply Program? This program addresses domestic, municipal, and industrial water...

  7. Electricity supply, district heating and supply of natural- and gas-works gas 1998

    International Nuclear Information System (INIS)

    2000-01-01

    This report is based on information covering enterprises producing, selling and transmitting electrical energy or producing and distributing hot water for district heating. The producers of electricity included in this report have either at least 100 kW in prime movers for electrical generation or at least 400 kW in prime movers and no public distribution. Enterprises are obliged by law to report these data. Data are requested concerning three types of statistical units: power stations, heating plants, and units reporting complete economic information (deliveries, sales value, production costs etc.). Power stations may be regarded as technical units and data are collected on technical equipment, consumption of fuels, production and own consumption of electrical energy. For heating plants data are collected on production and turnover of steam and hot water and on consumption of fuels and electrical energy. At the end of 1998 the installed capacity of generators amounted to 34 389 MW. Hydro-electrical capacity accounted for 48 % of total installed capacity. Compared to 1997 the capacity increased by 55 MW for hydro-electrical power and, decreased by 254 MW for conventional thermal power. Total capacity decreased by 147 MW or 0.4 %. The net production of electrical energy in 1998 amounted to 154 552 GWh, an increase of 6.4 % compared to 1997 The production of hydro-electrical power increased by 8.2 %. Hydro-electrical power accounted for 47 % of total production. Nuclear-power production increased by 6.2 % Conventional thermal-power production decreased by 28.9 %. The consumption of electricity (excl. transmission losses) increased by 0,8 % to 133 096 GWh. By consumption sectors the percentage changes were: in agriculture, etc. -9.9 %; in mining, quarrying and manufacturing +2.2 %; in construction -7.8 %; in electricity, heating, gas and water services -4.6 %; in commerce, real estate, etc. +1.8 %; in transport, storage and communication -2.9 %; in community, social

  8. Electric energy management - basis for a municipal public politics; Gestao da energia eletrica - bases para uma politica publica municipal

    Energy Technology Data Exchange (ETDEWEB)

    Kurahassi, Luiz Fernando

    2006-07-01

    Electricity is an input whose impact on the costs of the municipal public services varies according to the manner it is used and to the way it is obtained from the supplying company. The management of its use results in savings and in greater efficiency and quality of the delivered services - including the public lighting - besides, it softens environmental impacts and develops actions to orientate society towards energy-efficient consumption habits. The public sector has a significant share in the electricity final consumption in Brazil, trending to increase, but a room for consumption reduction and increase in energy efficiency can be seen in the municipalities. The purpose of this thesis is to identify concepts and set parameters that can be the basis of a public policy on electrical power management at the ambit of municipality. This paper reports a series of theoretical studies and empirical researches concerning the efficient use of electrical power in public services in cities of different countries and analyses the results reached from the application of models that successively work in the reality of cities from the Sao Paulo metropolitan area. It concludes that the municipality must play a role much more relevant than being a simple institutional electricity consumer, by proposing the basis for an intervention in the municipal reality. (author)

  9. Integration of biomass fast pyrolysis and precedent feedstock steam drying with a municipal combined heat and power plant

    International Nuclear Information System (INIS)

    Kohl, Thomas; Laukkanen, Timo P.; Järvinen, Mika P.

    2014-01-01

    Biomass fast pyrolysis (BFP) is a promising pre-treatment technology for converting biomass to transport fuel and in the future also for high-grade chemicals. BFP can be integrated with a municipal combined heat and power (CHP) plant. This paper shows the influence of BFP integration on a CHP plant's main parameters and its effect on the energetic and environmental performance of the connected district heating network. The work comprises full- and part-load operation of a CHP plant integrated with BFP and steam drying. It also evaluates different usage alternatives for the BFP products (char and oil). The results show that the integration is possible and strongly beneficial regarding energetic and environmental performance. Offering the possibility to provide lower district heating loads, the operation hours of the plant can be increased by up to 57%. The BFP products should be sold rather than applied for internal use as this increases the district heating network's primary energy efficiency the most. With this integration strategy future CHP plants can provide valuable products at high efficiency and also can help to mitigate global CO 2 emissions. - Highlights: • Part load simulation of a cogeneration plant integrated with biomas fast pyrolysis. • Analysis of energetic and environmental performance. • Assessment of different uses of the pyrolysis products

  10. Reconstruction of Low Pressure Gas Supply System

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2013-01-01

    Full Text Available The current reconstruction of residential areas in large cities especially with the developed heat-supply systems from thermal power stations and reduction of heat consumption for heating due to higher thermal resistance of building enclosing structures requires new technical solutions in respect of gas-supply problems. While making reconstruction of a gas-supply system of the modernized or new buildings in the operating zone of one gas-distribution plant it is necessary to change hot water-supply systems from gas direct-flow water heaters to centralized heat-supply and free gas volumes are to be used for other needs or gas-supply of new buildings with the current external gas distribution network.Selection of additional gas-line sections and points of gas-supply systems pertaining to new and reconstructed buildings for their connection to the current distribution system of gas-supply is to be executed in accordance with the presented methodology.

  11. Adapting to climate change : an introduction for Canadian municipalities

    International Nuclear Information System (INIS)

    Mehdi, B.

    2006-02-01

    Climate change studies have indicated that Canada will experience large shifts in weather patterns in the next few decades due to both natural variations as well as human activities that release greenhouse gases to the atmosphere. According to the Intergovernmental Panel on Climate Change, the world's average surface temperature is expected to increase by 1.4 to 5.8 degrees C over the period 1990-2100. The use of fossils fuels in transportation, manufacturing, heating, cooling, and electricity generation is the biggest source of GHGs such as carbon dioxide, methane, and nitrous oxide. The rest comes from land use activities, such as agriculture and forestry. Total GHG emissions in Canada amounted to 740 megatonnes in 2003. Municipalities are directly and indirectly responsible for almost half of those emissions. This document outlined decision-making processes to help municipal governments make informed decisions and take appropriate mitigative action. Topics of discussion focused on the effect of global warming on public health, agriculture, water, coastline and marine management. Among the impacts of climate change are droughts; diminished and lower quality surface water; a higher incidence of vector-borne diseases; more frequent heat waves with discomfort in urban centres; and, an increase in storm surges in coastal regions. The greatest concerns for most municipalities are intense precipitation, heavy winds, or ice storms. Examples of how 6 Canadian communities are starting to address climate change adaptation were presented in the hope that these examples will help raise awareness of climate change impacts in other communities and provide ideas as to how these challenges might be addressed. The Toronto Heat-Health Alert System, the Greater Vancouver Regional District Stormwater Management Program, the Halifax Regional Municipality ClimateSMART Initiative, Sept-Iles' Shoreline Erosion Program, the City of Iqaluit Sustainable Development strategy and the Tidal

  12. Fluidized-bed incineration plant equipped with waste heat boilers. Developed for mid-size municipalities

    Energy Technology Data Exchange (ETDEWEB)

    Handa, Hitoshi

    1988-01-20

    A fluidized bed incineration plant with a waste heat boiler was installed to dispose wastes in Sakura City on March, 1987 and has waste disposing capacity of 120tons/d. Sands are fluidized in the furnace at 700-800/sup 0/C and wastes are burned completely for a short time. The waste heat boiler is used to utilize waste heat to send steam to aquiculturing farms and hot water to the community plaza and further supplies steam to two 90kW back pressure turbines for driving forced draft fan used for the incineration plant. Harmful gases in waste gas are removed by the harmful gas eliminator to lower HCl to 120ppm or less and K value of SOx to 9.0 or less and then cleaned gas is exhausted through the electostatic precipitator and the chimney. Dust and fly ash are transferred to a reservior through a superior seal tight air transportation system, pelletized and disposed for land fill. Bulk waste disposing capacity is 50 tons/d and harmful wastes, magnetic materials, unburnable and burnable wastes are classified and separated. Separated iron purity is 95% or more. (4 figs, 2 photos)

  13. Survey report of year 2000 version. Feasibility study on energy efficiency/conservation, and environmental improvement of district heat and electricity supply station Radom City

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In order to promote the COP3 joint implementation, discussions were given on the district heat and electricity supply station in Radom City in Poland. Power capacity utilized above a certain level will be generated by cogeneration power plants according to the annual heat supply load patterns, and insufficient capacity will be supplied from the existing hot water boilers during winter when thermal load is high. Daily load variation will be handled by installing auxiliary combustion facilities of 20% of the full capacity. The power plants will be of natural gas burning gas-turbine cogeneration plants, and hot water will be supplied from the modified waste heat boilers. The cogeneration power plants will be capable of taking care of 80% of the annual supply quantity of heat. The heat supply capacity will be 72 MWt including the auxiliary combustion, and the electric power generation capacity will be 35 MWe. Improvement in thermal efficiency to 80% or higher will reduce coal consumption, resulting in saving of 28,117 toe/year after subtracting the increase in natural gas consumption. Reduction in CO2 emission will also be as large as 206,000 tons/year, causing air pollutants to be also reduced. Assuming the facility cost of 4,336 billion yen to be taken care by the Japanese environmental yen loan, the Polish National Fund loan, and the independent fund of the city of Radom, the IRRON investment over the operation period of 30 years is considerably good at 10%. The investment can be recovered in nine years, and the cash flow will have no problems. (NEDO)

  14. Partial costs of global climate change adaptation for the supply of raw industrial and municipal water: a methodology and application

    International Nuclear Information System (INIS)

    Ward, Philip J; Pauw, W Pieter; Brander, Luke M; Aerts, Jeroen C J H; Strzepek, Kenneth M; Hughes, Gordon A

    2010-01-01

    Despite growing recognition of the importance of climate change adaptation, few global estimates of the costs involved are available for the water supply sector. We present a methodology for estimating partial global and regional adaptation costs for raw industrial and domestic water supply, for a limited number of adaptation strategies, and apply the method using results of two climate models. In this paper, adaptation costs are defined as those for providing enough raw water to meet future industrial and municipal water demand, based on country-level demand projections to 2050. We first estimate costs for a baseline scenario excluding climate change, and then additional climate change adaptation costs. Increased demand is assumed to be met through a combination of increased reservoir yield and alternative backstop measures. Under such controversial measures, we project global adaptation costs of $12 bn p.a., with 83-90% in developing countries; the highest costs are in Sub-Saharan Africa. Globally, adaptation costs are low compared to baseline costs ($73 bn p.a.), which supports the notion of mainstreaming climate change adaptation into broader policy aims. The method provides a tool for estimating broad costs at the global and regional scale; such information is of key importance in international negotiations.

  15. Partial costs of global climate change adaptation for the supply of raw industrial and municipal water: a methodology and application

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Philip J; Pauw, W Pieter; Brander, Luke M; Aerts, Jeroen C J H [Institute for Environmental Studies (IVM), VU University Amsterdam (Netherlands); Strzepek, Kenneth M [Joint Program on the Science and Policy of Global Change, Massachusetts Institute of Technology, MA (United States); Hughes, Gordon A, E-mail: philip.ward@ivm.vu.nl [School of Economics, University of Edinburgh (United Kingdom)

    2010-10-15

    Despite growing recognition of the importance of climate change adaptation, few global estimates of the costs involved are available for the water supply sector. We present a methodology for estimating partial global and regional adaptation costs for raw industrial and domestic water supply, for a limited number of adaptation strategies, and apply the method using results of two climate models. In this paper, adaptation costs are defined as those for providing enough raw water to meet future industrial and municipal water demand, based on country-level demand projections to 2050. We first estimate costs for a baseline scenario excluding climate change, and then additional climate change adaptation costs. Increased demand is assumed to be met through a combination of increased reservoir yield and alternative backstop measures. Under such controversial measures, we project global adaptation costs of $12 bn p.a., with 83-90% in developing countries; the highest costs are in Sub-Saharan Africa. Globally, adaptation costs are low compared to baseline costs ($73 bn p.a.), which supports the notion of mainstreaming climate change adaptation into broader policy aims. The method provides a tool for estimating broad costs at the global and regional scale; such information is of key importance in international negotiations.

  16. 77 FR 47060 - Missouri Joint Municipal Electric Utility Commission; Notice of Filing

    Science.gov (United States)

    2012-08-07

    ... Municipal Electric Utility Commission filed a Proposed Revenue Requirement for reactive supply service under... Room in Washington, DC. There is an ``eSubscription'' link on the web site that enables subscribers to...

  17. Energy supply modelling of a low-CO 2 emitting energy system: Case study of a Danish municipality

    DEFF Research Database (Denmark)

    Sveinbjörnsson, Dadi Þorsteinn; Ben Amer-Allam, Sara; Hansen, Anders Bavnhøj

    2017-01-01

    Municipal activities play an important role in national and global CO2-emission reduction efforts, with Nordic countries at the forefront thanks to their energy planning tradition and high penetration of renewable energy sources. In this work, we present a case study of the Danish municipality...... dependent on changes in energy prices.We conclude that in order to achieve their CO2 emission goals in the most energy-efficient, cost-effective and sustainable way, municipalities similar to Sønderborg should compare a wide range of energy system configurations, for example, scenarios with a high degree...

  18. Development of environmentally-friendly high-efficiency energy utilization system. Research on optimum system design technology (Case study report on wide-area energy supply network system in Osaka Prefecture); Osakafu ni okeru koiki energy kyokyu network system no case study hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    A wide-area energy supply network model is fabricated for a region to be re-developed, and the model is assessed from the viewpoints of economy, environmental preservation, and energy conservation. The model is a combination of element technologies being developed under an Eco-Energy City project and some existing technologies. Although a wide-area heat supply system using high-temperature water is superior to district heating systems in energy conservation and environmental friendliness, yet it contains some unsolved problems relating to cost efficiency. The use of a vacuum-insulated tube as the heat supply main is better than the use of a double tube from every point of view. It is noted here that in the study of the Sakai district, the neighborhood of the old Sakai Port, an area in front of Sakai-shi Station of the Nankai Main Line, Nakamozu-Minami district, and Nakamozu-Kita district are defined to be the areas to be supplied with heat. Petroleum company C, glass mill C, and the Sakai Municipal Incineration Plant situated in the bay area are assumed to be the sources of waste heat. It is so set that the high-temperature water is to be transported at 170 degrees C and is to return at 140 degrees C. (NEDO)

  19. Reliability evaluation of power supply and distribution for special heat removal systems in nuclear power stations

    International Nuclear Information System (INIS)

    Jazbec, D.

    1982-01-01

    An example of the power supply and distribution of a Special Emergency Heat Removal System (SEHR) shows how an engineering organization may, with the aid of the analytical method of min-cut sets optimize the system reliability. Herein are given the necessary simple calculation methods. (Auth.)

  20. Development of heat pump technology in eco-energy city project

    Energy Technology Data Exchange (ETDEWEB)

    Omata, Tomio [New Energy Development Organization (Japan); Ogisu, Yoshihiro [Office of Eco-Energy City Project, Energy Conservation Center (Japan)

    1999-07-01

    In the New Sunshine Project conducted by MITI Japan, Eco-Energy City-Project covers the research area of utilization of industrial and municipal waste heat. For the further utilization of waste heat, several research programs are carried out for recovery and conversion of waste heat, transportation and storage of waste heat and final use of rather low temperature heat transported. Various types of heat driven heat pumps are developed in the Eco-Energy City Project. Concept of the Project is to utilize industrial and municipal waste heat for the city where energy demand is increasing. These heat pumps will contribute for the reduction of CO{sub 2} emission. (orig.)

  1. Current and future prospects for heat recovery from waste in European district heating systems: A literature and data review

    DEFF Research Database (Denmark)

    Persson, Urban; Münster, Marie

    2016-01-01

    Municipal solid waste has seen increasing annual volumes for many decades in contemporary Europe and constitutes, if not properly managed, an environmental problem due to local pollution and greenhouse gas emissions. From an energy perspective, waste is also an alternative fuel for power and heat...... to establish and assess current and future EU (European Union) waste generation and management. Main conclusions are that more heat can be recovered from current Waste-to-Energy facilities operating at low average heat recovery efficiencies, that efficient incineration capacity is geographically concentrated...... heat distribution infrastructures, without which no large-scale recovery and utilisation of excess heat is possible. In this paper, which aims to estimate municipal solid waste volumes available for heat recovery in European district heating systems in 2030, a literature and data review is performed...

  2. Economy and development of heating station enterprises managed by forest owners

    International Nuclear Information System (INIS)

    Tuomi, S.

    1997-01-01

    Private heating enterprises are a new form of heat generation for municipalities in Finland. In this type the entrepreneur acquires the fuel and takes care of the operation and monitoring of the heating station. The recompense is paid on the basis of the heat amount produced to avoid problems related to i.e. the energy content and quality of the fuel. The price of heat is typically bound with that of light fuel oil. Agreements based on the price development of district heat and chips are also used. In 1996 there were 36 such heating enterprises in operation in Finland, their total efficiency being 11.5 MW. The aim of the project is to improve the feasibility of various forms of heating enterprises and to start new heating enterprises. The feasibility is studied both from the viewpoint of the entrepreneur and the municipality. The feasibility is improved by developing production chains of heating enterprises and the operability of the heating stations. Establishment of new heating enterprises is promoted by producing and disseminating information to possible entrepreneurs and municipalities. (orig.)

  3. Economy and development of heating station enterprises managed by forest owners

    International Nuclear Information System (INIS)

    Tuomi, S.

    1998-01-01

    Private heating enterprises are a new form of heat generation for municipalities in Finland. In this type the entrepreneur acquires the fuel and takes care of the operation and monitoring of the heating station. The recompense is paid on the basis of the heat amount produced to avoid problems related to i.a. the energy content and quality of the fuel. The price of heat is typically bound with that of light fuel oil. Agreements based on the price development of district heat and chips are also used. In 1997 there were about 50 such heating enterprises in operation in Finland. The aim of the project is to improve the feasibility of various forms of heating enterprises and to start new heating enterprises. The feasibility is studied both from the viewpoint of the entrepreneur and the municipality. The feasibility is improved by developing production chains of heating enterprises and the operability of heating stations. Establishment of new heating enterprises is promoted by producing and disseminating information to possible entrepreneurs and municipalities. (orig.)

  4. Effect of materials mixture on the higher heating value: Case of biomass, biochar and municipal solid waste.

    Science.gov (United States)

    Boumanchar, Imane; Chhiti, Younes; M'hamdi Alaoui, Fatima Ezzahrae; El Ouinani, Amal; Sahibed-Dine, Abdelaziz; Bentiss, Fouad; Jama, Charafeddine; Bensitel, Mohammed

    2017-03-01

    The heating value describes the energy content of any fuel. In this study, this parameter was evaluated for different abundant materials in Morocco (two types of biochar, plastic, synthetic rubber, and cardboard as municipal solid waste (MSW), and various types of biomass). Before the evaluation of their higher heating value (HHV) by a calorimeter device, the thermal behavior of these materials was investigated using thermogravimetric (TGA) and Differential scanning calorimetry (DSC) analyses. The focus of this work is to evaluate the calorific value of each material alone in a first time, then to compare the experimental and theoretical HHV of their mixtures in a second time. The heating value of lignocellulosic materials was between 12.16 and 20.53MJ/kg, 27.39 for biochar 1, 32.60MJ/kg for biochar 2, 37.81 and 38.00MJ/kg for plastic and synthetic rubber respectively and 13.81MJ/kg for cardboard. A significant difference was observed between the measured and estimated HHVs of mixtures. Experimentally, results for a large variety of mixture between biomass/biochar and biomass/MSW have shown that the interaction between biomass and other compounds expressed a synergy of 2.37% for biochar 1 and 6.11% for biochar 2, 1.09% for cardboard, 5.09% for plastic and 5.01% for synthetic rubber. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Integration of biogas in municipal energy planning and supply

    Energy Technology Data Exchange (ETDEWEB)

    Nedergaard, N; Oertenblad, H [Herning Municipal Utilities, Herning (Denmark)

    1997-08-01

    The first biogas plants in Denmark were based on local initiatives and a great deal of idealism. The break through with technically well functioning plants came at the end of the 80`ies. The plants were based on animal manure, and the development came together with the growing environmental demands and the legislation concerning storage capacity and distribution of the manure. This contributed to an increasing interest in joint biogas plants, mainly from the agricultural sector, but also from the industry. Today Denmark has 19 biogas plants in operation, all based on manure co-digested with wastes from the food industry, and 15 farm-scale plants. Only three of the joint plants are owned by a municipality, one plant in Aarhus and two in Herning. (au)

  6. Feasibility and Supply Analysis of U.S. Geothermal District Heating and Cooling System

    Science.gov (United States)

    He, Xiaoning

    Geothermal energy is a globally distributed sustainable energy with the advantages of a stable base load energy production with a high capacity factor and zero SOx, CO, and particulates emissions. It can provide a potential solution to the depletion of fossil fuels and air pollution problems. The geothermal district heating and cooling system is one of the most common applications of geothermal energy, and consists of geothermal wells to provide hot water from a fractured geothermal reservoir, a surface energy distribution system for hot water transmission, and heating/cooling facilities to provide water and space heating as well as air conditioning for residential and commercial buildings. To gain wider recognition for the geothermal district heating and cooling (GDHC) system, the potential to develop such a system was evaluated in the western United States, and in the state of West Virginia. The geothermal resources were categorized into identified hydrothermal resources, undiscovered hydrothermal resources, near hydrothermal enhanced geothermal system (EGS), and deep EGS. Reservoir characteristics of the first three categories were estimated individually, and their thermal potential calculated. A cost model for such a system was developed for technical performance and economic analysis at each geothermally active location. A supply curve for the system was then developed, establishing the quantity and the cost of potential geothermal energy which can be used for the GDHC system. A West Virginia University (WVU) case study was performed to compare the competiveness of a geothermal energy system to the current steam based system. An Aspen Plus model was created to simulate the year-round campus heating and cooling scenario. Five cases of varying water flow rates and temperatures were simulated to find the lowest levelized cost of heat (LCOH) for the WVU case study. The model was then used to derive a levelized cost of heat as a function of the population density

  7. LEAP: local environmental action plan. Municipality of Lipkovo

    International Nuclear Information System (INIS)

    2004-01-01

    This document comprises all geo-environmental problems with adverse on the quality of the overall environment. Based on this, the document contains many scientific and expert statements and facts supported by data, diagrams maps, etc. At the same time, taking into consideration the problems appearing on the territory of Lipkovo Municipality, the environmental problems are by their priority presented as issues of first, second and third degree, requiring most urgent settlement through the leap document for the Municipality of Lipkovo. This is followed by the presentation of priorities and the strategy for elimination of degradation processes and establishment of environmental balance in the space. According to the current data, it seems that this Municipality is faced with numerous environmental problems, beginning with air pollution, water contamination, solid waste disposal, the landfill of the abandoned mine Lojane and the site around the Railroad Station at Tabanovci, supply of drinking water, destruction of forests, expansion of rural settlements over cultivable lands, the issue of space urbanization, unemployment, etc

  8. Feasibility Assessment of Using Power Plant Waste Heat in Large Scale Horticulture Facility Energy Supply Systems

    Directory of Open Access Journals (Sweden)

    Min Gyung Yu

    2016-02-01

    Full Text Available Recently, the Korean government has been carrying out projects to construct several large scale horticulture facilities. However, it is difficult for an energy supply to operate stably and economically with only a conventional fossil fuel boiler system. For this reason, several unused energy sources have become attractive and it was found that power plant waste heat has the greatest potential for application in this scenario. In this study, we performed a feasibility assessment of power plant waste heat as an energy source for horticulture facilities. As a result, it was confirmed that there was a sufficient amount of energy potential for the use of waste heat to supply energy to the assumed area. In Dangjin, an horticultural area of 500 ha could be constructed by utilizing 20% of the energy reserves. In Hadong, a horticulture facility can be set up to be 260 ha with 7.4% of the energy reserves. In Youngdong, an assumed area of 65 ha could be built utilizing about 19% of the energy reserves. Furthermore, the payback period was calculated in order to evaluate the economic feasibility compared with a conventional system. The initial investment costs can be recovered by the approximately 83% reduction in the annual operating costs.

  9. Sources of Water Supply and Water Quality for Local Consumption: The Case Study of Eco-Tourism Village, Suan Luang Sub- District Municipality, Ampawa District, Samut Songkram Province, Thailand

    OpenAIRE

    Paiboon Jeamponk; Tasanee Ponglaa; Patchapon Srisanguan

    2014-01-01

    The aim of this research paper was based on an examination of sources of water supply and water quality for local consumption, conducted at eco- tourism villages of Suan Luang Sub- District Municipality of Amphawa District, Samut Songkram Province. The study incorporated both questionnaire and field work of water testing as the research tool and method. The sample size of 288 households was based on the population of the district, whereas the selected sample water sources were from 60 househo...

  10. Restructuring of the electricity market. New general framework and management strategies for municipalities. Documentation of contributions to the IKU seminar; Strommarkt im Umbruch. Neue Rahmenbedingungen und Strategien fuer Kommunen. Veranstaltungsunterlagen

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, C. (comp.)

    2000-07-01

    The titles of the seven papers presented at the IKU seminar are as follows: 1. The emerging competitive electricity markets - Perspectives for municipalities. - 2. New supply offers and terms and conditions for power procurement of municipalities. - 3. Power procurement and awarding of contracts - legal framework and recommendations for municipalities in designing the tendering procedure in the competitive market environment. - 4. Experience of a municipality in the process of establishing a local pool of buyers. - 5. Experience obtained in defining new tender conditions and specifications for power supply to a municipal undertaking. - 6. Experience of a municipality obtained in negotiations with electricity supply undertakings. - 7. Invitations to tender for energy supply to municipalities - experience of the hessenENERGIE GmbH. (orig./CB) [German] Die Titel der in diesem Dokument abgedruckten sieben Beitraege zum IKU Seminar lauten: 1. Wettbewerb auf den Strommaerkten - Perspektiven fuer Kommunen. - 2. Neue Angebote und neue Konditionen fuer den Strombezug von Kommunen. - 3. Strombezug und Vergaberecht - Rechtlicher Rahmen und Empfehlungen zur Gestaltung der Vergabe bei oeffentlichen Auftraggebern. - 4. Erfahrungen mit der Bildung eines kommunalen Nachfragepools. - 5. Erfahrungen mit der Ausschreibung von Stromlieferungen fuer einen oeffentlichen Auftraggeber. - 6. Erfahrungen einer Kommune aus Verhandlungen ueber den Strombezug mit Versorgungsunternehmen. - 7. Ausschreibung von Energielieferungen fuer Kommunen - Erfahrungen und Angebote der hessenENERGIE GmbH. (orig./CB)

  11. Heat Roadmap Europe

    DEFF Research Database (Denmark)

    Hansen, Kenneth; Connolly, David; Lund, Henrik

    2015-01-01

    The cost of heat savings in buildings increase as more heat savings are achieved due to the state of the building stock and hence, alternatives other than savings typically become more economically feasible at a certain level of heat reductions. It is important to identify when the cost of heat...... savings become more expensive than the cost of sustainable heat supply, so society does not overinvest in heat saving measures. This study first investigates the heat saving potentials for different countries in Europe, along with their associated costs, followed by a comparison with alternative ways...... of supplying sustainable heating. Different heat production options are included in terms of individual and community heating systems. Furthermore, the levelised cost of supplying sustainable heat is estimated for both a single technology and from an energy system perspective. The results are analysed...

  12. Factors associated with inter-municipality differences in dental caries experience among Danish adolescents. An ecological study

    DEFF Research Database (Denmark)

    Ekstrand, K R; Christiansen, M E C; Qvist, V

    2009-01-01

    Ekstrand KR, Christiansen MEC, Qvist V, Ismail A. Factors associated with inter-municipality differences in dental caries experience among Danish adolescents. An ecological study. Community Dent Oral Epidemiol 2009; 00: 000-000. (c) 2009 John Wiley & Sons A/SAbstract - Background: Caries...... in the water supply and DMF-S values diminished in both years at a level above 0.35 ppm. The structured interview disclosed that municipalities with significant improvement in mean DMFS from 1999 to 2004 had established goals and were committed to the prevention of dental caries at the individual level...... on children and adolescents in Denmark has declined significantly over the last 30 years. Our first analysis in 1999, however, disclosed huge inter-municipality disparities in mean DMFS values as well as in prevalence of caries on Danish children; that fluoride in the water supply and the length...

  13. Economy and development of heating station enterprises managed by forest owners

    International Nuclear Information System (INIS)

    Tuomi, S.

    1998-01-01

    Private heating enterprises are a new form of heat generation for municipalities in Finland. In this type the entrepreneur acquires the fuel and takes care of the heating station. The recompense is paid on the basis of the heat amount produced to avoid problems related to i.a. the energy content and the quality of the fuel. The price of heat is typically bound to the price of the light fuel oil. Agreements based on the price development of district heat and chips are also used. In 1997 there were about 50 such enterprises in operation in Finland. The aim of the project is to improve the feasibility of various forms of heating enterprises and to start new heating enterprises. The feasibility is studied both from the viewpoint of the entrepreneur and the municipality. The feasibility is improved by developing production chains of heating enterprises and the operability of heating stations. Establishment of new heating enterprises is promoted by producing and disseminating information to prospective entrepreneurs and municipalities. (orig.) 2 figs., 2 tabs. Bioenergy Research programme

  14. ON THE ISSUE OF RATIONAL ORGANIZATION OF THE TEXTILE AND KNITWEAR ENTERPRISES HEAT AND POWER SUPPLY SYSTEM

    Directory of Open Access Journals (Sweden)

    V. N. Romaniuk

    2016-01-01

    Full Text Available The paper considers organization of the industrial enterprise heat and power supply system (HPSS, to be rational from the structure and flow parameter standpoint. Developing HPSS is one of the main lines of implementing energy-saving potential in volumes complying with dictates of the time on reducing the production cost energy component, which is especially vital for the light industry enterprises of Belarus. To reduce the complexity of the task the authors employ the hierarchical structure of HPSS. With regard to textile and knitwear enterprises, they show the irregularity of energy supply on the one hand, and of energy use on the other. The finishing departments of the specified enterprises ensure their thermo-technological status. It is proverbial that accomplished in terms of energy thermo-technological enterprises should not consume the electric energy produced in condensation electric power plants. Instead, for their production needs, they should use thermal energy and electricity generated in the CHP. At the same time, steam turbine CHPs of low power, and consequently of low initial parameters, cannot provide the required electrical and heat energy flow generation balance. The indicated circumstance among others accounts for prevalence of condensation electric power plants in the scheme of electrogenerating capacities that provide work for the light industry enterprises. And this leads to irregularity of their energy supply. Transition to gas CHPs with required scheme of the energy flow generation is associated primarily with creation of inherent generating sources, which in its turn poses a number of challenges on modification of the thermal treatment schemes of technological flows. The problem is solved in package with developing energy consumption of the finishing department as well as the entire enterprise. The study shows the capability of utilizing low pressure hot water alongside with steam, which paves the way to the recuperative

  15. Experimental evaluation of a heat pump for the water-supply heating of a public swimming pool

    International Nuclear Information System (INIS)

    López, R; Vaca, M; Terres, H; Lizardi, A; Morales, J; Chávez, S

    2017-01-01

    In this work the analysis of the thermodynamic behavior of heat pumps (HP) which supply the energy needed in the public pool at the Aquatic Center of Azcapotzalco was performed. There are 18 installed HP’s but only those needed to provide the energy required are alternately activated. The evaluation was conducted during May and June of 2015. We selected one of the HP to implement temperature and pressure gauges at the inlet and outlet of the compressor. The measurements were made every day at three times, 6:30, 13:00 and 18:00 hours. In a period of 24 hours, 1 000 L evaporated, there was no variation registered overnight, since the pool was covered with plastic to avoid loss of the fluid. The heat pump provided 150 kW to maintain the water temperature at the right level of operation, namely 28 °C. The coefficients of performance (COP) of the HP were 6.39 at 6:30, 7.42 at 13:00 and 7:32 at 18:00 hrs., values which are very close to the one provided by the manufacturer. (paper)

  16. Experimental evaluation of a heat pump for the water-supply heating of a public swimming pool

    Science.gov (United States)

    López, R.; Vaca, M.; Terres, H.; Lizardi, A.; Morales, J.; Chávez, S.

    2017-01-01

    In this work the analysis of the thermodynamic behavior of heat pumps (HP) which supply the energy needed in the public pool at the Aquatic Center of Azcapotzalco was performed. There are 18 installed HP’s but only those needed to provide the energy required are alternately activated. The evaluation was conducted during May and June of 2015. We selected one of the HP to implement temperature and pressure gauges at the inlet and outlet of the compressor. The measurements were made every day at three times, 6:30, 13:00 and 18:00 hours. In a period of 24 hours, 1 000 L evaporated, there was no variation registered overnight, since the pool was covered with plastic to avoid loss of the fluid. The heat pump provided 150 kW to maintain the water temperature at the right level of operation, namely 28 °C. The coefficients of performance (COP) of the HP were 6.39 at 6:30, 7.42 at 13:00 and 7:32 at 18:00 hrs., values which are very close to the one provided by the manufacturer.

  17. Biodrying process: A sustainable technology for treatment of municipal solid waste with high moisture content.

    Science.gov (United States)

    Tom, Asha P; Pawels, Renu; Haridas, Ajit

    2016-03-01

    Municipal solid waste with high moisture content is the major hindrance in the field of waste to energy conversion technologies and here comes the importance of biodrying process. Biodrying is a convective evaporation process, which utilizes the biological heat developed from the aerobic reactions of organic components. The numerous end use possibilities of the output are making the biodrying process versatile, which is possible by achieving the required moisture reduction, volume reduction and bulk density enhancement through the effective utilization of biological heat. In the present case study the detailed research and development of an innovative biodrying reactor has been carried out for the treatment of mixed municipal solid waste with high moisture content. A pilot scale biodrying reactor of capacity 565 cm(3) was designed and set up in the laboratory. The reactor dimensions consisted of an acrylic chamber of 60 cm diameter and 200 cm height, and it was enveloped by an insulation chamber. The insulation chamber was provided to minimise the heat losses through the side walls of the reactor. It simulates the actual condition in scaling up of the reactor, since in bigger scale reactors the heat losses through side walls will be negligible while comparing the volume to surface area ratio. The mixed municipal solid waste with initial moisture content of 61.25% was synthetically prepared in the laboratory and the reactor was fed with 109 kg of this substrate. Aerobic conditions were ensured inside the reactor chamber by providing the air at a constant rate of 40 litre per minute, and the direction of air flow was from the specially designed bottom air chamber to the reactor matrix top. The self heating inside reactor matrix was assumed in the range of 50-60°C during the design stage. Innovative biodrying reactor was found to be efficiently working with the temperature inside the reactor matrix rising to a peak value of 59°C by the fourth day of experiment (the

  18. External control of the public water supply in 29 Brazilian cities

    Directory of Open Access Journals (Sweden)

    Suzely Adas Saliba Moimaz

    2012-02-01

    Full Text Available The fluoridation of public water supplies is considered the most efficient public health measure for dental caries prevention. However, fluoride levels in the public water supply must be kept constant and adequate for the population to gain preventive benefit. The aim of this study was to analyze fluoride levels in the public water supply of 29 Brazilian municipalities during a 48-month period from November 2004 to October 2008. Three collection sites were defined for each source of municipal public water supply. Water samples were collected monthly and analyzed at the Research Laboratory of the Nucleus for Public Health (NEPESCO, Public Health Postgraduate Program, Araçatuba Dental School (UNESP. Of the 6862 samples analyzed, the fluoride levels of 53.5% (n = 3671 were within the recommended parameters, those of 30.4% (n = 2084 were below these parameters, and those of 16.1% (n = 1107 were above recommended values. Samples from the same collection site showed temporal variability in fluoride levels. Variation was also observed among samples from collection sites with different sources within the same municipality. Although 53.5% of the samples contained the recommended fluoride levels, these findings reinforce the importance of monitoring to minimize the risk of dental fluorosis and to achieve the maximum benefit in the prevention of dental caries.

  19. Population growth, accessibility spillovers and persistent borders: Historical growth in West-European municipalities.

    Science.gov (United States)

    Jacobs-Crisioni, Chris; Koomen, Eric

    2017-06-01

    Lack of cross-border transport supply has repeatedly been blamed for the fact that national borders limit spatial interaction and, consequently, the growth of border regions. This study applies an accessibility approach to investigate for most municipalities in ten countries in mainland West Europe if foreign transport supply is lagging behind, and if population growth in these municipalities has been affected by the limits that national borders have imposed on market access. To do so, data describing historical population changes and road networks between 1961 and 2011 have been used. The results show that in the study area, cross-border transport accessibility was not at a disadvantage in 1961 and has since then grown even more than domestic accessibility. However, municipal population growth has depended almost exclusively on domestic market access. Processes of economic international integration in the study area are found to coincide with the growth of cross-border accessibility, but do not have a clear coincidence with the effects of cross-border accessibility on population growth.

  20. Municipal climate protection as a measure for sustainable energy supply under the conditions of globalization and liberalization? An empirical investigation considering the municipal actors and public utility companies; Kommunaler Klimaschutz als Instrument einer nachhaltigen Energieversorgung unter den Bedingungen von Globalisierung und Liberalisierung? Eine empirische Untersuchung unter besonderer Beruecksichtigung der Akteure Kommune und Stadtwerke

    Energy Technology Data Exchange (ETDEWEB)

    Bielitza-Mimjaehner, Ralf

    2007-03-01

    With the background of the threatening global warming that requires a reduction of greenhouse gas emission by 20 % until 2010 und by 80% until 2050 in Germany, t is reasonable to consider local or municipal climate protection activities. A climate protection politics ''from the bottom'' is not only contributing to a real greenhouse gas reduction, but also triggering the stagnant international climate politics and enhances the sustainable development on a local level. Due to this fact amongst others the Enquete commission of the German Bundestag ''sustainable energy supply under the conditions of globalization and liberalization'' identifies the municipal climate protection activities as important part within the mix of measures that will allow the initiation of an alteration of the actual energy system toward a sustainable energy supply in the long-run. The consequences of globalization and liberalization on the municipal level have not yet been discussed or considered by the Enquete commission. This thesis analyses the conditions induced by the globalization and liberalization on the municipal climate protection activities as constituent of a sustainable energy supply. The project is focusing on the municipal actors and the public utility companies as central point of the considerations. [German] Vor dem Hintergrund einer drohenden globalen Erwaermung, die eine Reduktion der klimawirksamen Treibhausgase bundesweit um 20 % bis 2010 und um 80 % bis 2050 noetig macht, sind Klimaschutzaktivitaeten auf einer lokalen oder kommunalen Ebene in mehreren Dimensionen sinnvoll. Den tatsaechlichen, bezifferbaren Reduktionen von CO2, die hier geleistet werden, gesellt sich ein ''vorbildhafter'' Druck auf eine stockende internationale Klimapolitik hinzu, ebenso leistet die ''Klimaschutzpolitik von unten'' einer nachhaltigen Entwicklung der lokalen Ebene durch Lerneffekte Vorschub. Unter anderem aus

  1. Lead isotopes in tap water: implications for Pb sources within a municipal water supply system

    International Nuclear Information System (INIS)

    Cheng Zhongqi; Foland, Kenneth A.

    2005-01-01

    Residential tap waters were investigated to examine the feasibility of using isotopic ratios to identify dominant sources of water Pb in the Columbus (Ohio, USA) municipal supply system. Overall, both the concentrations, which are generally low (0.1-28 μg/L), and isotopic compositions of tap water Pb show wide variations. This contrasts with the situation for a limited number of available service lines, which exhibit only a limited Pb-isotope variation but contain Pb of two very different types with one significantly more radiogenic than the other. Most tap water samples in contact with Pb service lines have Pb-isotope ratios that are different from the pipe Pb. Furthermore, the Pb isotope compositions of sequentially drawn samples in the same residence generally are similar, but those from separate residences are different, implying dominant Pb sources from domestic plumbing. A separate pilot study at two residences without Pb service lines shows isotopic similarity between water and solders in each house, further suggesting that the major Pb sources are domestic in these cases and dominated by Pb from solder joints. Although complicated by the broad range of overall Pb-isotope variations observed and limited by sample availability, the results suggest that Pb isotopes can be used effectively to constrain the sources of Pb in tap waters, especially for individual houses where multiple source candidates can be identified

  2. Comparison of the Performance of Chilled Beam with Swirl Jet and Diffuse Ceiling Air Supply: Impact of Heat Load Distribution

    DEFF Research Database (Denmark)

    Bertheussen, Bård; Mustakallio, Panu; Kosonen, Risto

    2013-01-01

    The impact of heat load strength and positioning on the indoor environment generated by diffuse ceiling air supply and chilled beam with radial swirl jet was studied and compared. An office room with two persons and a meeting room with six persons were simulated in a test room (4.5 x 3.95 x 3.5 m3......) and Category B thermal environment in the meeting room at high heat load of 94 W∙m−2. The air distribution pattern was influenced by the convective flows from the heat sources. The maximum local velocity in the occupied zone was 0.23–0.26 m∙s−1. The diffuse ceiling supply did not ensure complete mixing...... temperature was controlled at 24 °C. The quality of the generated indoor environment as defined in ISO standard 7730 (2005) was assessed based on comprehensive physical measurements. The systems created Category A thermal environment in cooling situations at heat load of 50 W∙m−2 and 78 W∙m−2 (office room...

  3. Effect of discharges from re-channeled rivers and municipal runoff ...

    African Journals Online (AJOL)

    OWNER

    municipal runoff on water quality of Opa reservoir, Ile-. Ife, Southwest ... 2. 1Department of Zoology, Obafemi Awolowo University, Ile-Ife, Nigeria. 2Natural ... water quality parameters that are modified by land uses. (Deacon and ... The reservoir was primarily created to supply potable water to the ... Inter-relationship among.

  4. An autonomous nuclear power plant with integrated nuclear steam supply system designed for electric power and heat supply in remote areas with difficult access

    International Nuclear Information System (INIS)

    Adamovich, L.A.; Grechko, G.I.; Lapin, B.D.; Ulasevich, V.K.; Shishkin, V.A.

    1997-01-01

    The paper contains basic conceptual principles used to develop the technical assignment for an autonomous nuclear power plant with integrated nuclear steam supply system (NSSS) designed to provide heat and electricity for areas which are remote with difficult access. The paper also describes technical procedures and equipment, NPP thermal hydraulic flow chart, steam generator design, safety aspects as well as operational and maintenance procedures. (author)

  5. Mapping of potential heat sources for heat pumps for district heating in Denmark

    International Nuclear Information System (INIS)

    Lund, Rasmus; Persson, Urban

    2016-01-01

    The ambitious policy in Denmark on having a 100% renewable energy supply in 2050 requires radical changes to the energy systems to avoid an extensive and unsustainable use of biomass resources. Currently, wind power is being expanded and the increasing supply of electricity is slowly pushing the CHP (combined heat and power) plants out of operation, reducing the energy efficiency of the DH (district heating) supply. Here, large heat pumps for district heating is a frequently mentioned solution as a flexible demand for electricity and an energy efficient heat producer. The idea is to make heat pump use a low temperature waste or ambient heat source, but it has so far been very unclear which heat sources are actually available for this purpose. In this study eight categories of heat sources are analysed for the case of Denmark and included in a detailed spatial analysis where the identified heat sources are put in relation to the district heating areas and the corresponding demands. The analysis shows that potential heat sources are present near almost all district heating areas and that sea water most likely will have to play a substantial role as a heat source in future energy systems in Denmark. - Highlights: • The availability of heat sources for heat pumps in Denmark are mapped and quantified. • A novel methodology for assessment of low temperature industrial excess heat is presented. • There are heat sources available for 99% of district heating networks in Denmark. • The concentration of heat sources is generally bigger around bigger cities than smaller. • Ambient temperature heat sources will be more needed in district heating of big cities.

  6. Energy utilization: municipal waste incineration. Final report

    Energy Technology Data Exchange (ETDEWEB)

    LaBeck, M.F.

    1981-03-27

    An assessment is made of the technical and economical feasibility of converting municipal waste into useful and useable energy. The concept presented involves retrofitting an existing municipal incinerator with the systems and equipment necessary to produce process steam and electric power. The concept is economically attractive since the cost of necessary waste heat recovery equipment is usually a comparatively small percentage of the cost of the original incinerator installation. Technical data obtained from presently operating incinerators designed specifically for generating energy, documents the technical feasibility and stipulates certain design constraints. The investigation includes a cost summary; description of process and facilities; conceptual design; economic analysis; derivation of costs; itemized estimated costs; design and construction schedule; and some drawings.

  7. Heat planning for fossil-fuel-free district heating areas with extensive end-use heat savings: A case study of the Copenhagen district heating area in Denmark

    International Nuclear Information System (INIS)

    Harrestrup, M.; Svendsen, S.

    2014-01-01

    The Danish government plans to make the Danish energy system to be completely free of fossil fuels by 2050 and that by 2035 the energy supply for buildings and electricity should be entirely based on renewable energy sources. To become independent from fossil fuels, it is necessary to reduce the energy consumption of the existing building stock, increase energy efficiency, and convert the present heat supply from fossil fuels to renewable energy sources. District heating is a sustainable way of providing space heating and domestic hot water to buildings in densely populated areas. This paper is a theoretical investigation of the district heating system in the Copenhagen area, in which heat conservation is related to the heat supply in buildings from an economic perspective. Supplying the existing building stock from low-temperature energy resources, e.g. geothermal heat, might lead to oversized heating plants that are too expensive to build in comparison with the potential energy savings in buildings. Long-term strategies for the existing building stock must ensure that costs are minimized and that investments in energy savings and new heating capacity are optimized and carried out at the right time. - Highlights: • We investigate how much heating consumption needs to be reduced in a district heating area. • We examine fossil-fuel-free supply vs. energy conservations in the building stock. • It is slightly cost-beneficial to invest in energy renovation from today for a societal point of view. • It is economically beneficial for district heating companies to invest in energy renovations from today. • The cost per delivered heat unit is lower when energy renovations are carried out from today

  8. Multicriteria optimization approach to design and operation of district heating supply system over its life cycle

    Science.gov (United States)

    Hirsch, Piotr; Duzinkiewicz, Kazimierz; Grochowski, Michał

    2017-11-01

    District Heating (DH) systems are commonly supplied using local heat sources. Nowadays, modern insulation materials allow for effective and economically viable heat transportation over long distances (over 20 km). In the paper a method for optimized selection of design and operating parameters of long distance Heat Transportation System (HTS) is proposed. The method allows for evaluation of feasibility and effectivity of heat transportation from the considered heat sources. The optimized selection is formulated as multicriteria decision-making problem. The constraints for this problem include a static HTS model, allowing considerations of system life cycle, time variability and spatial topology. Thereby, variation of heat demand and ground temperature within the DH area, insulation and pipe aging and/or terrain elevation profile are taken into account in the decision-making process. The HTS construction costs, pumping power, and heat losses are considered as objective functions. Inner pipe diameter, insulation thickness, temperatures and pumping stations locations are optimized during the decision-making process. Moreover, the variants of pipe-laying e.g. one pipeline with the larger diameter or two with the smaller might be considered during the optimization. The analyzed optimization problem is multicriteria, hybrid and nonlinear. Because of such problem properties, the genetic solver was applied.

  9. EPA RE-Powering America's Lands: Kansas City Municipal Farm Site ₋ Biomass Power Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hunsberger, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mosey, G. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-01-01

    Through the RE-Powering America's Land initiative, the economic and technical feasibility of utilizing biomass at the Kansas City, Missouri, Municipal Farm site, a group of City-owned properties, is explored. The study that none of the technologies we reviewed--biomass heat, power and CHP--are economically viable options for the Municipal Farms site. However, if the site were to be developed around a future central biomass heating or CHP facility, biomass could be a good option for the site.

  10. Electricity supply, district heating and supply of natural and gasworks gas 2011; El-, gas- och fjaerrvaermefoersoerjningen 2011

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-02-15

    Decline in electricity use: The final consumption of electricity in the country (excluding losses) amounted in 2011 to 130.6 TWh. It meant a decline of 3.4 percent compared with the year before. The industry's use grew by 0.9 percent to 53.8 TWh. Household use (permanent housing and second homes) declined to 33.7 TWh (-9.6 percent). While other application within the service sector and public administration declined to 43.0 TWh (-3.2 percent). Increase in electricity generation: Electricity generation increased in 2011. Net production increased by 1.8 percent to 147.5 TWh, compared with the previous year. The largest increase observed for wind power, which rose by 74.2 percent to 6.1 TWh. Water power was virtually unchanged (66.7 TWh). The conventional thermal power dropped to 16.8 TWh, a decline of 11.9 percent. Nuclear power increased by 4.3 percent to 58.0 TWh. Power exchanges with foreign countries gave in 2011 a surplus of 7.2 TWh. Reduced heating supplies: Deliveries of heat to the final use declined in 2011. Delivered-na totaled 48.1 TWh, which represents a decrease of 16.1 percent compared with the year before.

  11. Vulnerability to Urban Heat Island in São Paulo Municipality: An Approach to Support the Mitigation Measures Implementation in Urban Planning

    Directory of Open Access Journals (Sweden)

    Juliana Siqueira-Gay

    2017-10-01

    Full Text Available In the practice of urban and environmental planning, especially in the context of adaptation to environmental changes, there is a demand for studies that integrate social, economic and environmental information of the population and related risk. Particularly in large urban centers, waterproofing and verticalization have the potential to increase local air temperature, triggering the phenomenon of heat islands. Therefore, this phenomenon has side effects such as public health problems, pollution and changes in the air circulation. In view of the risks and consequences of the urban heat islands, this paper aims to analyze the priority areas for implementing measures to mitigate the effects of the urban heat islands phenomenon in São Paulo City (Brazil. A vulnerability index was proposed considering the social and environmental dimensions, relating the capacity of adaptation, sensitivity and exposure to the occurrence of the phenomenon of urban heat islands. Besides that, measures to mitigate the effects associated with heat islands in urban planning were identified. The central regions are critical for exposure and the outskirts, for adaptive capacity and sensitivity, both considered priorities for the implementation of mitigation measures. In addition, strategies such as implementation and conservation of green spaces, preservation of water bodies, urban design change, as well as use of materials with high reflectance are also listed and partially foreseen in the Municipal Strategic Master Plan to mitigate the effects of urban heat island.

  12. District heating versus local heating - Social supportability

    International Nuclear Information System (INIS)

    Matei, Magdalena; Enescu, Diana; Varjoghie, Elena; Radu, Florin; Matei, Lucian

    2004-01-01

    District heating, DH, is an energy source which can provide a cost-effective, environmentally friendly source of heat and power for cities, but only in the case of well running systems, with reasonable technological losses. The benefits of DH system are well known: environmental friendly, energy security, economic and social advantages. DH already covers 60% of heating and hot water needs in transition economies. Today, 70 % of Russian, Latvian and Belarus homes use DH, and heating accounts for one-third of total Russian energy consumption. Yet a large number of DH systems in the region face serious financial, marketing or technical problems because of the policy framework. How can DH issues be best addressed in national and local policy? What can governments do to create the right conditions for the sustainable development of DH while improving service quality? What policies can help capture the economic, environmental and energy security benefits of co-generation and DH? To address these questions, the International Energy Agency (IEA) hosted in 2002 and 2004 conference focusing on the crucial importance of well-designed DH policies, for exchanging information on policy approaches. The conclusions of the conference have shown that 'DH systems can do much to save energy and boost energy security, but stronger policy measures are needed to encourage wise management and investment. With a stronger policy framework, DH systems in formerly socialist countries could save the equivalent of 80 billion cubic meters of natural gas a year through supply side efficiency improvements. This is greater than total annual natural gas consumption in Italy'. More efficient systems will also decrease costs, reducing household bills and making DH competitive on long-term. This paper presents the issues: -Theoretical benefits of the district heating and cooling systems; - Municipal heating in Romania; - Technical and economic problems of DH systems and social supportability; - How

  13. Heat supply from nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Stach, V [Ustav Jaderneho Vyzkumu CSKAE, Rez (Czechoslovakia)

    1978-05-01

    The current state of world power production and consumption is assessed. Prognoses made for the years 1980 to 2000 show that nuclear energy should replace the major part of fossil fuels not only in the production of power but also in the production of heat. In this respect high-temperature reactors are highly prospective. The question is discussed of the technical and economic parameters of dual-purpose heat and power plants. It is, however, necessary to solve problems arising from the safe siting of nuclear heat and power plants and their environmental impacts. The economic benefits of combined power and heat production by such nuclear plants is evident.

  14. Heat supply planning for the ecological housing community Munksøgård

    DEFF Research Database (Denmark)

    Karlsson, Kenneth Bernard; Petrovic, Stefan; Næraa, Rikke

    2016-01-01

    paper compares results from techno-economic energy system analysis, simple private-economic analysis and assessment of externalities related to the heat supply and discusses the differences in conclusions - is the economic optimal solution different from a system or private-economic point of view......? The techno-economic energy system analysis is done using TIMES-DTU model, which optimizes over all sectors in Denmark and all periods until 2050. The result from this model gives the least expensive solution from the overall system point of view. A spreadsheet model has been developed to do the private-economic...

  15. Heat supply planning for the ecological housing community Munksøgård

    DEFF Research Database (Denmark)

    Karlsson, Kenneth Bernard; Petrovic, Stefan; Næraa, Rikke

    2015-01-01

    paper compares results from techno-economic energy system analysis, simple private-economic analysis and assessment of externalities related to the heat supply and discusses the differences in conclusions - is the economic optimal solution different from a system or private-economic point of view......? The techno-economic energy system analysis is done using TIMES-DTU model, which optimizes over all sectors in Denmark and all periods until 2050. The result from this model gives the least expensive solution from the overall system point of view. A spreadsheet model has been developed to do the private-economic...

  16. TEXT poloidal coil systems power supplies

    International Nuclear Information System (INIS)

    Hutchins, S.H.; Brower, D.F.

    1977-01-01

    TEXT is a convertional iron core tokamak which will have a toroidal field of 3.0 Tesla produced by room temperature copper coils and a maximum plasma current pulse of 400 kA induced by a 40 turn Ohmic Heating coil. The major radius is 100 cm and the minor radius of the plasma is 28 cm. The machine is intended for basic research in tokamak plasma physics and atomic physics and is designed primarily to provide a stable hot plasma, extremely good diagnostic access, and reliable operation. The discharge pulse length will be 300 msec and the repetition period 120 seconds. Power for the toroidal field coils and for the ohmic heating supply is provided by a 100 MVA energy storage alternator. The vertical field, horizontal field, fast positioning, and discharge cleaning power supply systems are powered from the Tokamak Laboratory power mains. The ohmic heating power system consists of an SCR controlled premagnetizing supply and commutation circuit, the main ohmic heating capacitor bank to provide plasma breakdown and current rise, and an SCR controlled power supply which sustains plasma current during the 300 ms pulse. The vertical field power system uses a small capacitor bank and an SCR controlled supply. The horizontal field has a reversible SCR controlled supply, and the fast positioning coils are powered by bipolar output transistor controlled supplies. This paper describes the loads, required wave forms, and the specifications for these power supply systems

  17. Study of solar energy utilization for the needs of municipal equipments of the city of Tunis

    Energy Technology Data Exchange (ETDEWEB)

    Cassou, J; Potron, A

    1982-08-01

    This report presents the main ways of utilization of solar energy in Tunisia: hot sanitary water, active solar space heating and bioclimatism. Several municipal installations (municipal showers, kindergartens, sport complexes, townhall...) have been visited and one gives the actions which have been suggested for these ones.

  18. Municipalities as facilitators, regulators and energy consumers for enhancing the dissemination of biogas technology in Denmark

    Directory of Open Access Journals (Sweden)

    Rikke Lybæk

    2015-06-01

    Full Text Available Biogas provides many potential benefits as far as renewable energy production, environmental protection and job creation etc. Insufficient initiatives from government/municipalities however hamper more biogas plants to be established, and hence that the large manure potential, and other types of digestible organic waste materials, are being utilized for energy purposes. By looking at municipalities as energy consumer’s, that constitutes a local market for biogas, as regulator’s, enforcing new requirements and regulations on the biogas sector, and finally as facilitator’s, assisting and helping involved stakeholders, the development of the biogas sector could be enhanced. We suggest to: Slim the documentation needed; Require that a part of the municipal heat are provided by biogas; Identify alternative heat markets for sale of non-upgraded biogas; Map new types of gas boosters, etc. We conclude that the role of municipalities as facilitator’s is the most important support that local governments can provide to support biogas.

  19. Nuclear refinery - advanced energy complex for electricity generation, clean fuel production, and heat supply

    International Nuclear Information System (INIS)

    McDonald, C.F.

    1992-01-01

    In planning for increased U.S. energy users' demand after the year 2000 there are essentially four salient vectors: (1) reduced reliance on imported crude oil; (2) provide a secure supply with stable economics; (3) supply system must be in concert with improved environment goals; and (4) maximum use to be made of indigenous resources. For the last decade of this century the aforementioned will likely be met by increasing utilization of natural gas. Early in the next century, however, in the U.S. and the newly industrializing nations, the ever increasing energy demand will only be met by the combined use of uranium and coal. The proposed nuclear refinery concept is an advanced energy complex that has at its focal point an advanced modular helium reactor (MHR). This nuclear facility, together with a coal feedstock, could contribute towards meeting the needs of the four major energy sectors in the U.S., namely electricity, transportation, industrial heating and chemical feedstock, and space and water heating. Such a nuclear/coal synergistic system would be in concert with improved air quality goals. This paper discusses the major features and multifaceted operation of a nuclear refinery concept, and identifies the enabling technologies needed for such an energy complex to become a reality early in the 21st century. (Author)

  20. The composition, heating value and renewable share of the energy content of mixed municipal solid waste in Finland

    International Nuclear Information System (INIS)

    Horttanainen, M.; Teirasvuo, N.; Kapustina, V.; Hupponen, M.; Luoranen, M.

    2013-01-01

    Highlights: • New experimental data of mixed MSW properties in a Finnish case region. • The share of renewable energy of mixed MSW. • The results were compared with earlier international studies. • The average share of renewable energy was 30% and the average LHVar 19 MJ/kg. • Well operating source separation decreases the renewable energy content of MSW. - Abstract: For the estimation of greenhouse gas emissions from waste incineration it is essential to know the share of the renewable energy content of the combusted waste. The composition and heating value information is generally available, but the renewable energy share or heating values of different fractions of waste have rarely been determined. In this study, data from Finnish studies concerning the composition and energy content of mixed MSW were collected, new experimental data on the compositions, heating values and renewable share of energy were presented and the results were compared to the estimations concluded from earlier international studies. In the town of Lappeenranta in south-eastern Finland, the share of renewable energy ranged between 25% and 34% in the energy content tests implemented for two sample trucks. The heating values of the waste and fractions of plastic waste were high in the samples compared to the earlier studies in Finland. These high values were caused by good source separation and led to a low share of renewable energy content in the waste. The results showed that in mixed municipal solid waste the renewable share of the energy content can be significantly lower than the general assumptions (50–60%) when the source separation of organic waste, paper and cardboard is carried out successfully. The number of samples was however small for making extensive conclusions on the results concerning the heating values and renewable share of energy and additional research is needed for this purpose

  1. The composition, heating value and renewable share of the energy content of mixed municipal solid waste in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Horttanainen, M., E-mail: mika.horttanainen@lut.fi; Teirasvuo, N.; Kapustina, V.; Hupponen, M.; Luoranen, M.

    2013-12-15

    Highlights: • New experimental data of mixed MSW properties in a Finnish case region. • The share of renewable energy of mixed MSW. • The results were compared with earlier international studies. • The average share of renewable energy was 30% and the average LHVar 19 MJ/kg. • Well operating source separation decreases the renewable energy content of MSW. - Abstract: For the estimation of greenhouse gas emissions from waste incineration it is essential to know the share of the renewable energy content of the combusted waste. The composition and heating value information is generally available, but the renewable energy share or heating values of different fractions of waste have rarely been determined. In this study, data from Finnish studies concerning the composition and energy content of mixed MSW were collected, new experimental data on the compositions, heating values and renewable share of energy were presented and the results were compared to the estimations concluded from earlier international studies. In the town of Lappeenranta in south-eastern Finland, the share of renewable energy ranged between 25% and 34% in the energy content tests implemented for two sample trucks. The heating values of the waste and fractions of plastic waste were high in the samples compared to the earlier studies in Finland. These high values were caused by good source separation and led to a low share of renewable energy content in the waste. The results showed that in mixed municipal solid waste the renewable share of the energy content can be significantly lower than the general assumptions (50–60%) when the source separation of organic waste, paper and cardboard is carried out successfully. The number of samples was however small for making extensive conclusions on the results concerning the heating values and renewable share of energy and additional research is needed for this purpose.

  2. Absorption heat pump for a potable water supply in a solar house

    Energy Technology Data Exchange (ETDEWEB)

    Elshamarka, S [Military Technical Coll., Cairo (EG)

    1991-01-01

    Solar houses usually have good potential in arid areas. These areas often suffer from not only a shortage of conventional energy sources, but also of potable water supplies. In this study, a solar air-conditioning system including an absorption heat pump, already in production since the early 1980s, is described for potable water production while performing its air-conditioning duty in a solar house. Compiled weather-conditions of the Hurgada area, on the Red Sea coast of Egypt, were employed for the prediction of the system's productivity, if it were installed in such a locality. An evaluation of the system's feasibility has been conducted. (author).

  3. Heat Roadmap Europe

    DEFF Research Database (Denmark)

    David, Andrei; Mathiesen, Brian Vad; Averfalk, Helge

    2017-01-01

    The Heat Roadmap Europe (HRE) studies estimated a potential increase of the district heating (DH) share to 50% of the entire heat demand by 2050, with approximately 25–30% of it being supplied using large-scale electric heat pumps. This study builds on this potential and aims to document that suc......The Heat Roadmap Europe (HRE) studies estimated a potential increase of the district heating (DH) share to 50% of the entire heat demand by 2050, with approximately 25–30% of it being supplied using large-scale electric heat pumps. This study builds on this potential and aims to document...

  4. Environmental Aspects as Assessment Criteria in Municipal Heat Energy Decisions - Case of Eno Energy Cooperative

    Energy Technology Data Exchange (ETDEWEB)

    Puhakka, Asko [North Karelia Univ. of Applied Sciences, Joensuu (Finland)

    2006-07-15

    The aim of this paper is to provide information whether it is possible to consider the sustainable development perspectives in the decision making of the district energy decision. The new EU-directives concerning public procurements allow the use of environmental aspects as selection criteria. The focus here is on small-scale district heating systems and their fuel-supply chains. The comparable fuels included the analysis are forest chips, heavy fuel oil, light fuel oil and peat. The paper focuses to the concept of the sustainable development and establishes the indicators for ecological-, social- and economical aspects of the district heating. The indicators are utilized in the case study on the Eno Energy Cooperative. The equivalent CO{sub 2} emissions from the production and the combustion of the fuel, the employment impacts of the fuel production and the formation of the price of energy for the consumers are considered. After presenting the sustainable development indicators in the case of Eno Energy Cooperative, the investment models of heat entrepreneurship business are discussed. Finally, we also raise an attention into important aspects to be considered when establishing a local district heating scheme. The indicators used in this presentation show that the use of forest chips in energy production has positive effect through the reduced greenhouse gases. The use of wood in energy production also provides employment opportunities and is more favourable to consumers, because of the steady fuel price when compared to other alternative fuels.

  5. Renewable energy in district heating grids. A realistic perspective?; Erneuerbare Energien in Waermenetzen. Eine realistische Perspektive?

    Energy Technology Data Exchange (ETDEWEB)

    Bruns, Elke [Technische Univ. Berlin (Germany). Inst. fuer Landschaftsarchitektur und Umweltplanung; Futterlieb, Matthias; Ohlhorst, Doerte [Technische Univ. Berlin (Germany). Zentrum Technik und Gesellschaft (ZTG); Wenzel, Bernd [Ingenieurbuero fuer neue Energie (IfnE), Teltow (Germany)

    2012-09-15

    The heating sector holds high potentials for cutting CO{sub 2} emissions by using renewable energy. These potentials can be tapped either by substituting fossil fuels in individual heating units or by using renewable energy in district heating networks, which may be more efficient. This paper asks for the options to increase the share of renewable energy in Germany's district heating infrastructure and for the restrictions that are hampering further development in this field. It critically discusses the relevant technical, political and economic challenges and determinants. District heating networks fuelled by renewable energy are not only competing with fossil fuels in individual heating units. They are also facing the more fundamental question regarding the preconditions for a profitable and worthwhile operation of grid-bound heat supply. The economic viability of heat grids has to be analyzed on a case-by-case basis, since it depends predominantly on individual framework conditions. Those include a decreasing heat demand due to improving energy performance of buildings, competing gas grids already in place and the complex interest structures of the actors involved. The growth rates that were observed in the last years were predominantly achieved in small renewably fuelled district heating networks. Even under favourable framework conditions, there is a need for additional supportive measures to increase the share of renewable energy in district heating grids. This mix of policy instruments should encompass measures to increase the implementation rates of municipal heat utilization concepts, measures to decrease the initial investments needed, as well as public relations to improve the user perception of grid-bound heat supply. However, the options to increase the share of renewable heat in existing large-scale grids are considered to be rather limited. (orig.)

  6. Sustainability analysis. Development of various indicators of sustainability for technical environmental analysis and evaluation of local heat supply networks on the basis of regenerative energies in comparison to fossil energy sources

    International Nuclear Information System (INIS)

    Hehenberger-Risse, Diana

    2013-06-01

    The aim of this thesis is to define indicators to evaluate local heat supply systems based on renewable energy compared to fossil energy reference scenarios. With these indicators a assessment matrix was developed as a planning instrument for the realization of sustainable and energy-efficient local heat supply systems. Further inferences from single projects on regions can be done. In these thesis a method was developed to assess the sustainability of local heat supply systems with the focus on ecology under consideration of economically and social aspects. This method uses a set of indicators composed of Input-, Output-, Efficiency- and Balance indicators. To realize advancement in comparison to present situations, an environmental quality target to advance the environmental impacts of minimum 75% was defined. For the developing and application of the indicators different examples from projects and scenarios of combined heat production from Biomass, Biogas, Solar heat combined with near-surface geothermal storage; geothermal energy and fossil peakload supply were calculated. These scenarios were related to a basis fossil energy scenario. Overall, the two district heating projects Speichersdorf and Mitterteich were compared. In this case, the project Speichersdorf with different coverage areas and decrease heat densities was investigated. The lengths of electrical grid of two areas are 10,828 m and 6,027 m. Those were opposed to the biomass district-heating project Mitterteich with a grid length of 360 m and a higher heat density decrease. Furthermore, a scenario for heat supply was designed and calculated using geothermal plant operating in duplicate to provide heat to the large coverage area for the storage project village. The calculation of the various processes and scenarios was performed with the program GEMIS 4.8 based on the total heat generated (final energy) by the respective supply type. The study examined the main system components; boilers, solar heat

  7. Exergy analysis of biogas production from a municipal solid waste landfill

    DEFF Research Database (Denmark)

    Xydis, George; Nanaki, E.; Koroneos, C.

    2013-01-01

    In the energy area, intensive efforts are being made over the last years to bridge the supply area with renewable energy sources and the demand side with energy conservation. Energy recovery from municipal solid waste landfills can play a contributing role in the solution of problems of both waste...

  8. New CO{sub 2} neutral city area with integrated district heating system of the future in Hoeje Taastrup - Phase 1: Preparation of demonstration. Final report; Denmark; Ny CO{sub 2}-neutral bydel med fremtidens integrerede fjernvarmesystem i Hoeje Taastrup - Fase 1: Forberedelse af demonstration. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Kaarup Olsen, P.; Hummelshoej, R.M. (Cowi A/S (Denmark))

    2011-02-15

    The project has contributed considerably to developing and maturing many climate initiatives in Hoeje Taastrup municipality - including particularly having made an effort to develop and develop the plans for a CO{sub 2}-neutral quarter called 'Vision Gammelsa'. In this context, the project has involved relevant actors in the development of an energy concept for the quarter. The concept was later used as basis for an EU application to the CONCERTO programme, for which Hoeje Taastrup achieved final grant agreement in December 2009. In this way, the municipality obtained funding for a 6-year project 'ECO-Life' which will focus on energy measures in Hedehusene, Floeng and the Gammelsoe region. The project will be carried out in cooperation with a municipality in Lithuania (Birstonas) and Belgium (Kortrijk). In addition, the project supported the development of a climate plan and policy in the municipality. During the life of the project, the council has carried out a wide range of ambitious initiatives which to a great extent stems from the project and in particularly the cooperation that the project has brought along. Based on a preliminary draft proposal for the district, a number of energy concepts have been assessed that can make the district CO{sub 2}-neutral. Primary focus has been on the heat supply. It is recommended to establish a low-temperature heating network, since such a solution provides the best possibility of using surplus heat and renewable energy sources, and in the future, perhaps already in 15 years, district heating from VEKS will be CO{sub 2}-neutral. Three energy efficient and CO{sub 2} efficient district heating solutions have been investigated in more detail: 1) Local low-temperature district heating network with ground heat and solar heat. 2) Low-temperature district heating network based on return heat from the HTF/VEKS system. 3) Low-temperature district heating network with heat driven heat pumps and solar heat. All

  9. District heating in Italy

    International Nuclear Information System (INIS)

    Sacchi, E.

    1998-01-01

    The legislative act establishing the electric monopoly virtually shut out the district heating associated with electricity cogeneration, while other laws, issued to counteract the effects of oil shocks, allowed municipal utilities to do so. Thus, district heating has experienced some development, though well below its possibilities. The article analyses the reasons for this lagging, reports district heating data and projects its forecasts against the Kyoto Protocol objectives [it

  10. Energy recovery from waste incineration: Assessing the importance of district heating networks

    International Nuclear Information System (INIS)

    Fruergaard, T.; Christensen, T.H.; Astrup, T.

    2010-01-01

    Municipal solid waste incineration contributes with 20% of the heat supplied to the more than 400 district heating networks in Denmark. In evaluation of the environmental consequences of this heat production, the typical approach has been to assume that other (fossil) fuels could be saved on a 1:1 basis (e.g. 1 GJ of waste heat delivered substitutes for 1 GJ of coal-based heat). This paper investigates consequences of waste-based heat substitution in two specific Danish district heating networks and the energy-associated interactions between the plants connected to these networks. Despite almost equal electricity and heat efficiencies at the waste incinerators connected to the two district heating networks, the energy and CO 2 accounts showed significantly different results: waste incineration in one network caused a CO 2 saving of 48 kg CO 2 /GJ energy input while in the other network a load of 43 kg CO 2 /GJ. This was caused mainly by differences in operation mode and fuel types of the other heat producing plants attached to the networks. The paper clearly indicates that simple evaluations of waste-to-energy efficiencies at the incinerator are insufficient for assessing the consequences of heat substitution in district heating network systems. The paper also shows that using national averages for heat substitution will not provide a correct answer: local conditions need to be addressed thoroughly otherwise we may fail to assess correctly the heat recovery from waste incineration.

  11. 77 FR 42486 - Intent To Prepare an Integrated Water Supply Storage Reallocation Report; Environmental Impact...

    Science.gov (United States)

    2012-07-19

    ... Water Supply Storage Reallocation Report; Environmental Impact Statement for Missouri River Municipal... Policy Act of 1969 (NEPA), as amended and the 1958 Water Supply Act, as amended, the U.S. Army Corps of... purpose of the study is to determine if changes to the current allocation of storage for M&I water supply...

  12. Water supply diagnosis in the municipality of Cajazeiras, Paraíba State, Brazil

    Directory of Open Access Journals (Sweden)

    José Adalberto da Silva Filho

    2016-04-01

    Full Text Available The water supply is a key factor for the development of the population in a region. The mapping areas that are not supplied with drinking water is an important mechanism, once the vulnerable locations are identified, which leads to establish policies and programs to mitigate the problem. Thus, this paper aims at examining areas that present vulnerability in access to water in the municipality of Cajazeiras, Paraíba State, Brazil. In order to carry this research out, data from the Brazilian Institute of Geography and Statistics were analyzed. The results indicate a disproportion in access to water between rural and urban areas, with the first being very vulnerable to contamination factors. It is necessary environmental education programs for sustainable water use, the development of technologies to ensure good quality water and the well being of the people, by the high risk of water-related diseases caused by the contamination that may occur in capture, transport and storage of water. Diagnóstico do abastecimento de água no município de Cajazeiras – PB, BrasilResumo: O abastecimento de água é um fator determinante para o desenvolvimento da população em uma região. O mapeamento de zonas que não são abastecidos com água potável é um mecanismo importante, uma vez que são identificadas as localidades que apresentam vulnerabilidade, sendo assim possível estabelecer políticas e programas que amenizem a problemática. Dessa forma, o presente trabalho tem por objetivo analisar as zonas que apresentam vulnerabilidade no acesso à água no município de Cajazeiras - PB, por meio de dados obtidos junto ao Instituto Brasileiro de Geografia e Estatística. Os resultados indicam uma desproporcionalidade no acesso à água entre as zonas rurais e urbanas, sendo a primeira muito vulnerável a fatores de contaminação. Dessa forma, faz-se necessário programas de educação ambiental para o uso sustentável da água, como também o

  13. Plans for promoting district energy-saving visions for City of Wakkanai; Wakkanai-shi chiiki sho energy vision suishin keikakusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    The district energy-saving visions and promotion plans therefor are drawn for City of Wakkanai, to promote energy saving and abatement of gas emissions which cause global warming. The conception of the energy-saving introduction project includes introduction of co-generation systems in the facilities of pivotal functions in the city center, and energy-saving systems in a municipal heated pool and public hot spring facilities. The facilities of pivotal functions in the city, e.g., the municipal office buildings, municipal hospital and all-around culture center of the city are supplied with heat in a centralized manner from the energy center, and the energy-saving effect is expected when co-generation systems are introduced in the energy center. The study results indicate that introduction of the co-generation systems in the energy center has a potential energy-saving effect of 2,400Gcal/y. The energy-saving effects are also analyzed for each of the municipal office buildings, municipal hospital, all-around culture center, municipal heated pool and public hot spring facilities, including those potentially realized by improving illumination and air supply/discharge facilities. (NEDO)

  14. Types, risks and market of municipal bonds

    Directory of Open Access Journals (Sweden)

    Grujić Miloš

    2012-01-01

    Full Text Available Municipal bonds are issued by cities, municipalities or other local communities in order to quickly raise funds to cover current budget deficits, finish infrastructure projects for production and distribution of thermal energy, improve water supply, road construction, sports and recreation centers, schools or to fund such projects on more favorable terms than to borrow from banks. In this manner, necessary conditions are created for faster development of the real sector. The aim of this study is to evaluate the importance, possibilities and effects of the bond issue in the Republika Srpska aimed at securing funding for and development of local communities. Good examples that local government bonds enhance community development include capital markets in countries that have made the transition from the socialist system design, similar to the market of the Republika Srpska, like the Polish, Slovakian, Hungarian and Croatian markets. Issues of municipal bonds in the Republika Srpska succeeded mostly due to the workings of Investment-Development Bank of RS. However, it certainly shows that further high-quality municipal bonds could attract more interest from various institutional investors, especially mutual funds and insurance companies, and investors who are more risk-averse will be able to familiarize and inform themselves with the functioning of capital markets. In this manner, our capital market would confirm its essential role and thus become a generator of overall economic development of the Republika Srpska because it would enable more efficient collection and allocation of capital resources.

  15. Water supply impacts of nuclear fall

    International Nuclear Information System (INIS)

    Hobbs, B.F.; Luo, Y.; Maciejowski, M.E.; Chester, C.V.

    1989-01-01

    “Nuclear winter,” more properly called “nuclear fall,” could be caused by injection of large amounts of dust into the atmosphere. Besides causing a decrease in temperature, it could be accompanied by “nuclear drought,” a catastrophic decrease in precipitation. Dry land agriculture would then be impossible, and municipal, industrial, and irrigation water supplies would be diminished. It has been argued that nuclear winter/fall poses a much greater threat to human survival than do fall out or the direct impacts of a conflict. However, this does not appear to be true, at least for the U.S. Even under the unprecedented drought that could result from nuclear fall, water supplies would be available for many essential activities. For the most part, ground water supplies would be relatively invulnerable to nuclear drought, and adequate surface supplies would be available for potable uses. This assumes that conveyance facilities and power supplies survive a conflict largely intact or can be repaired

  16. Municipal energy audit: a practical guide to the identification of energy expenditures

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    This publication was designed to provide small- to medium-sized Canadian municipalities with a ready-to-use, practical guide to indentify energy consumption and costs in all those operations that normally fall under the control of municipal governments. The manual was based on 7 pilot audits conducted in Ottawa, Ontario, Montague and Summerside, Prince Edward Island, Granby, Quebec, Victoria, British Columbia, St. John, New Brunswick, and Winnipeg, Manitoba, from which summaries of energy consumption patterns were drawn. Audit analysis is explained for such municipal responsibilities as street lighting, water supply, sewage disposal, public transit, police and fire protection services, garbage collection and disposal, snow and ice control and road maintenance in general, with figures presented from the survey results. A description of the audit method and worksheet forms are also included. 3 figs., 33 tabs.

  17. Determination of Ground Heat Exchangers Temperature Field in Geothermal Heat Pumps

    Science.gov (United States)

    Zhurmilova, I.; Shtym, A.

    2017-11-01

    For the heating and cooling supply of buildings and constructions geothermal heat pumps using low-potential ground energy are applied by means of ground exchangers. The process of heat transfer in a system of ground exchangers is a phenomenon of complex heat transfer. The paper presents a mathematical modeling of heat exchange processes, the temperature fields are built which are necessary for the determination of the ground array that ensures an adequate supply of low potential energy excluding the freezing of soil around the pipes in the ground heat exchangers and guaranteeing a reliable operation of geothermal heat pumps.

  18. FY1999 Meeting of The Society of Heating, Air-Conditioning and Sanitary Engineering of Japan. Hot water supply system; 1999 nendo gakujutsu koenkai gaiyo. Kyuto

    Energy Technology Data Exchange (ETDEWEB)

    Oze, H. [Toyo University, Tokyo (Japan)

    1999-12-05

    G-5 and 6 measure and investigate actual state of use of hot water supply systems in dormitories used by persons living alone without their families and by unmarried persons to collect fundamental data. G-5 considers how hot water is used, by making a questionnaire survey on the subject houses, and identifies the consumption trend of heat, water and hot water in the hot water supply systems as a whole. G-6 selected eleven houses from among the houses discussed in the previous report to identify the trend of use of hot water by each house. Also, quantity of hot water used in every day of the week is estimated. G-7 discusses methods for estimating water temperatures at faucets of water pipes from the water sources. This is intended to raise the accuracy of tap water temperature conversion coefficient by districts used for calculating estimated heat quantity as a parameter 'hot water supply energy consumption coefficient' to evaluate energy saving performance of a hot water supply facility. G-8 performs numerical simulations changing different parameters in the hot water supply piping system by using a heat loss calculation model for the existing household hot water supply piping. It executes evaluation on energy conservation performance of each model. G-9 estimates efficiency of instantaneous household gas hot water supply devices, not only on thermal efficiency of devices during steady state combustion, but also on non-steady state such as start-up, and discusses methods to derive actual efficiency by using calculations. (translated by NEDO)

  19. Impact of small-scale storage systems on the photovoltaic penetration potential at the municipal scale

    Science.gov (United States)

    Ramirez Camargo, Luis; Dorner, Wolfgang

    2016-04-01

    municipality using a series of indicators. These indicators include: a) the total photovoltaic installed capacity, b) the total storage installed capacity, c) the output variability, d) the total unfulfilled demand, e) total excess energy, f) total properly supplied energy, g) the loss of power supply probability, h) the amount of hours of supply higher than the highest demand in a year, i) the number of hours, when supply is 1.5. times higher than the highest demand in a year, and j) the additional storage energy capacity and power required to store all excess energy generated by the photovoltaic installations. The comparison of the proposed indicators serves to quantify the contribution that household-sized small-scale storage systems would make to the energy balance of the studied municipality. Increased installed energy storage capacity allows a higher roof-top photovoltaic share and improves energy utilization, variability and reliability indicators. The proposed methodology serves also to determine the amount of storage capacity with the highest positive impact on the local energy balance.

  20. Design of serially connected district heating heat pumps utilising a geothermal heat source

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    The design of two heat pumps (HP), connected in series, was investigated for operation in the district heating (DH) network of the Greater Copenhagen area, Denmark. The installation was dimensioned to supply 7.2 MW of heat at a temperature of 85 °C. The heat pumps utilise a geothermal heat source...

  1. Establishing an environmental profile of water supply in South Africa

    CSIR Research Space (South Africa)

    Brent, AC

    2006-11-01

    Full Text Available -losses in the supply system must receive attention, especially in the municipal-controlled part. Water quality impacts are also important, although through supporting processes, and specifically electricity generation. The boosting requirements attribute most...

  2. Optimal planning for the sustainable utilization of municipal solid waste

    Energy Technology Data Exchange (ETDEWEB)

    Santibañez-Aguilar, José Ezequiel [Chemical Engineering Department, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán 58060 (Mexico); Ponce-Ortega, José María, E-mail: jmponce@umich.mx [Chemical Engineering Department, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán 58060 (Mexico); Betzabe González-Campos, J. [Institute of Chemical and Biological Researches, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán 58060 (Mexico); Serna-González, Medardo [Chemical Engineering Department, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán 58060 (Mexico); El-Halwagi, Mahmoud M. [Chemical Engineering Department, Texas A and M University, College Station, TX 77843 (United States); Adjunct Faculty at the Chemical and Materials Engineering Department, Faculty of Engineering, King Abdulaziz University, P.O. Box 80204, Jeddah 21589 (Saudi Arabia)

    2013-12-15

    Highlights: • An optimization approach for the sustainable management of municipal solid waste is proposed. • The proposed model optimizes the entire supply chain network of a distributed system. • A case study for the sustainable waste management in the central-west part of Mexico is presented. • Results shows different interesting solutions for the case study presented. - Abstract: The increasing generation of municipal solid waste (MSW) is a major problem particularly for large urban areas with insufficient landfill capacities and inefficient waste management systems. Several options associated to the supply chain for implementing a MSW management system are available, however to determine the optimal solution several technical, economic, environmental and social aspects must be considered. Therefore, this paper proposes a mathematical programming model for the optimal planning of the supply chain associated to the MSW management system to maximize the economic benefit while accounting for technical and environmental issues. The optimization model simultaneously selects the processing technologies and their location, the distribution of wastes from cities as well as the distribution of products to markets. The problem was formulated as a multi-objective mixed-integer linear programing problem to maximize the profit of the supply chain and the amount of recycled wastes, where the results are showed through Pareto curves that tradeoff economic and environmental aspects. The proposed approach is applied to a case study for the west-central part of Mexico to consider the integration of MSW from several cities to yield useful products. The results show that an integrated utilization of MSW can provide economic, environmental and social benefits.

  3. Optimal planning for the sustainable utilization of municipal solid waste

    International Nuclear Information System (INIS)

    Santibañez-Aguilar, José Ezequiel; Ponce-Ortega, José María; Betzabe González-Campos, J.; Serna-González, Medardo; El-Halwagi, Mahmoud M.

    2013-01-01

    Highlights: • An optimization approach for the sustainable management of municipal solid waste is proposed. • The proposed model optimizes the entire supply chain network of a distributed system. • A case study for the sustainable waste management in the central-west part of Mexico is presented. • Results shows different interesting solutions for the case study presented. - Abstract: The increasing generation of municipal solid waste (MSW) is a major problem particularly for large urban areas with insufficient landfill capacities and inefficient waste management systems. Several options associated to the supply chain for implementing a MSW management system are available, however to determine the optimal solution several technical, economic, environmental and social aspects must be considered. Therefore, this paper proposes a mathematical programming model for the optimal planning of the supply chain associated to the MSW management system to maximize the economic benefit while accounting for technical and environmental issues. The optimization model simultaneously selects the processing technologies and their location, the distribution of wastes from cities as well as the distribution of products to markets. The problem was formulated as a multi-objective mixed-integer linear programing problem to maximize the profit of the supply chain and the amount of recycled wastes, where the results are showed through Pareto curves that tradeoff economic and environmental aspects. The proposed approach is applied to a case study for the west-central part of Mexico to consider the integration of MSW from several cities to yield useful products. The results show that an integrated utilization of MSW can provide economic, environmental and social benefits

  4. HEAT PUMP USING SUBSOIL WATERS AS LOW TEMPERATURE HEAT SOURCE

    Directory of Open Access Journals (Sweden)

    Denysova Alla

    2015-08-01

    Full Text Available One of the basic directions of perfection of heat supply systems is the tendency of transition to the low-temperature heating systems based on application of heat pump installations. We consider heat supply system with heat pump installations using subsoil waters. Numerical simulation of thermal processes in the elements of a single-stage and double-stage heat pump systems has been worked out. Values of depths of wells and their quantity, necessary for effective operation of the offered installations, and values of capacity of electric water pumps for subsoil waters unit are calculated. Capacity of compressor electric drive and coefficient of performance of heat pump for the conditions of the city of Odessa are presented.

  5. Energy supply between state, local government, and economy. Energieversorgung zwischen Staat, Gemeinde und Wirtschaft

    Energy Technology Data Exchange (ETDEWEB)

    Loewer, W.

    1989-01-01

    The central theme in the current discussion about the decentralization of the structures of energy supply in the Federal Republic of Germany and about the possibilities for implementing the reform on the basis of the valid law is a competency of the local government for energy provision by virtue of its 'general responsibility' or its 'tasks as a caterer for basic needs' (Daseinsvorsorge). The question raised thereby in relation to constitutional law, municipal economy law and energy law are thoroughly studied and answered in the book. It deals with the complexes 'catering for basic needs', 'public task', and 'decentralization' in the energy-political discussion, giving selected examples; with basic traits of the development of electric power supply as a many-sided system of energy provision; with the competency of the national or local government for ensuring electric power supply based on its being a 'caterer for basic needs', or electric power supply, being a public task; and with electric power supply as a municipal task. (orig.).

  6. Solar-Biomass hybrid system for process heat supply in medium scale hotels in Sri Lanka

    OpenAIRE

    Abeywardana, Asela M.A.J.

    2016-01-01

    This study aimed at evaluating and demonstrating the feasibility of using Concentrated Solar Thermal technology combined with biomass energy technology as a hybrid renewable energy system to supply the process heat requirements in small scale industries in Sri Lanka. Particularly, the focus was to apply the concept to the expanding hotel industry, for covering the thermal energy demand of a medium scale hotel. Solar modules utilize the rooftop area of the building to a valuable application. L...

  7. Trans-Americas leads the way into municipal textile recycling

    Energy Technology Data Exchange (ETDEWEB)

    Ridgley, H.

    1998-08-01

    Most textile waste in the US still goes to the landfill--an estimated 6.6 million tons each year. But thanks to the efforts of textile recycles--such as Trans-Americas Textile Recycling CO. (Brooklyn, NY)--another 1.25 million tons gets salvaged for reuse overseas or as a feedstock for the wiping and fiber industries, according to the Council for Textile Recycling. In an era where global population levels are increasing the demand for textile waste from the Western world and municipalities are struggling to reach their waste diversion goals, boosting textile recovery rates makes sense. And it`s a waste that can be easily incorporated into existing municipal curbside or drop-off recycling programs. Since 1942, when the company first opened its doors in Brooklyn, NY, it purchased textile discards from charities. While those discards still make up the majority of Trans-Americas` supply, in the last two years, the company also began purchasing post-consumer material from municipalities. Textiles are definitely going to be an increasingly important part of recycling, as states look to meet their mandates.

  8. LeBreton Flats district heating: Institutional issues

    Energy Technology Data Exchange (ETDEWEB)

    Gerow, L.B.; Bernstein, H.

    1981-12-01

    Despite the growing popularity in Europe of district heating as an alternative to conventional systems, a number of institutional barriers blocked the road to its successful implementation in Canada. These hurdles include questions of ownership, operation/administration, consumer accountability, financial arrangements, and general consumer acceptance of a new technology. In deciding on ownership, the major issues were legal. Provincial laws to be complied with included The Municipal Franchises Act, The Public Utilities Act, The Municipal Act and The Ontario Municipal Board Act. The operation and administration of the project were also beset with legal complications. The relevant laws were The Boilers and Pressure Vessels Act, and The Environmental Assessment Act. How to charge individual users (consumer accountability) raised a number of technical problems including metering and rate-setting for hot water distribution, and heat borrowing between units. The report recommends that groups planning to implement district heating are advised to allow plenty of lead time for obtaining approvals and franchising arrangements so as not to jeopardize construction schedules. 3 refs.

  9. Survey of minipower plant for municipal solid waste firing

    International Nuclear Information System (INIS)

    Merkkiniemi, R.; Hyoety, P.; Saiha, E.

    1999-01-01

    Dumping of municipal waste to disposal areas has caused environmental problems, and this has led to more sophisticated disposal systems and high prices. That and a general demand to reduce the quantity of waste require new solutions, and a question has been arisen whether combustion could be used to treat waste. This project is concentrating to bum waste in a small-scale power plant. The background is one 10-MW pilot in Tampere city based on smelting furnace and a 0.3-MW pyrolyse furnace. The results of these from the viewpoint of operation and effluent were satisfactory and the burning process used is in line with the latest regulations. The second aspect is the economy of waste handling. The minipower plant is designed for reasonable small municipalities, abt 20 000 inhabitants or 1 - 20 MW heat input. According to several feasibility studies this method is the cheapest way to handle waste. A local heat demand is used to support the economy. The prices of products, heat and power, and cost are of the same level as the market prices. Thus, we expect a economical and environmentally safe operation with the minipower plant and it will also give a hint to solve a higher capacity demand of one unit. (orig.)

  10. Oxygen demand for the stabilization of the organic fraction of municipal solid waste in passively aerated bioreactors

    International Nuclear Information System (INIS)

    Kasinski, Slawomir; Wojnowska-Baryla, Irena

    2014-01-01

    Highlights: • The use of an passively aerated reactor enables effective stabilization of OFMSW. • Convective air flow does not inhibit the aerobic stabilization of waste. • The use of an passively aerated reactor reduces the heat loss due to convection. • The volume of supplied air exceeds 1.7–2.88 times the microorganisms demand. - Abstract: Conventional aerobic waste treatment technologies require the use of aeration devices that actively transport air through the stabilized waste mass, which greatly increases operating costs. In addition, improperly operated active aeration systems, may have the adverse effect of cooling the stabilized biomass. Because active aeration can be a limiting factor for the stabilization process, passive aeration can be equally effective and less expensive. Unfortunately, there are few reports documenting the use of passive aeration systems in municipal waste stabilization. There have been doubts raised as to whether a passive aeration system provides enough oxygen to the organic matter mineralization processes. In this paper, the effectiveness of aeration during aerobic stabilization of four different organic fractions of municipal waste in a reactor with an integrated passive ventilation system and leachate recirculation was analyzed. For the study, four fractions separated by a rotary screen were chosen. Despite the high temperatures in the reactor, the air flow rate was below 0.016 m 3 /h. Using Darcy’s equation, theoretical values of the air flow rate were estimated, depending on the intensity of microbial metabolism and the amount of oxygen required for the oxidation of organic compounds. Calculations showed that the volume of supplied air exceeded the microorganisms demand for oxidation and endogenous activity by 1.7–2.88-fold

  11. Cob biomass supply for combined heat and power and biofuel in the north central USA

    International Nuclear Information System (INIS)

    Schmer, Marty R.; Dose, Heather L.

    2014-01-01

    Corn (Zea mays L.) cobs are being evaluated as a potential bioenergy feedstock for combined heat and power generation (CHP) and conversion into a biofuel. The objective of this study was to determine corn cob availability in north central United States (Minnesota, North Dakota, and South Dakota) using existing corn grain ethanol plants as a proxy for possible future co-located cellulosic ethanol plants. Cob production estimates averaged 6.04 Tg and 8.87 Tg using a 40 km radius area and 80 km radius area, respectively, from existing corn grain ethanol plants. The use of CHP from cobs reduces overall GHG emissions by 60%–65% from existing dry mill ethanol plants. An integrated biorefinery further reduces corn grain ethanol GHG emissions with estimated ranges from 13.9 g CO 2  equiv MJ −1 to 17.4 g CO 2  equiv MJ −1 . Significant radius area overlap (53% overlap for 40 km radius and 86% overlap for 80 km radius) exists for cob availability between current corn grain ethanol plants in this region suggesting possible cob supply constraints for a mature biofuel industry. A multi-feedstock approach will likely be required to meet multiple end user renewable energy requirements for the north central United States. Economic and feedstock logistics models need to account for possible supply constraints under a mature biofuel industry. - Highlights: • Corn cob biomass was estimated for the north central United States region. • Cobs were evaluated for combined heat and power generation and bioethanol. • Co-located ethanol plants showed a reduction in greenhouse gas emissions. • Biomass supply constraints may occur under a mature cellulosic ethanol scenario

  12. Integrated multiscale simulation of combined heat and power based district heating system

    International Nuclear Information System (INIS)

    Li, Peifeng; Nord, Natasa; Ertesvåg, Ivar Ståle; Ge, Zhihua; Yang, Zhiping; Yang, Yongping

    2015-01-01

    Highlights: • Simulation of power plant, district heating network and heat users in detail and integrated. • Coupled calculation and analysis of the heat and pressure losses of the district heating network. • District heating is not preferable for very low heat load due to relatively high heat loss. • Lower design supply temperatures of the district heating network give higher system efficiency. - Abstract: Many studies have been carried out separately on combined heat and power and district heating. However, little work has been done considering the heat source, the district heating network and the heat users simultaneously, especially when it comes to the heating system with large-scale combined heat and power plant. For the purpose of energy conservation, it is very important to know well the system performance of the integrated heating system from the very primary fuel input to the terminal heat users. This paper set up a model of 300 MW electric power rated air-cooled combined heat and power plant using Ebsilon software, which was validated according to the design data from the turbine manufacturer. Then, the model of heating network and heat users were developed based on the fundamental theories of fluid mechanics and heat transfer. Finally the combined heat and power based district heating system was obtained and the system performances within multiscale scope of the system were analyzed using the developed Ebsilon model. Topics with regard to the heat loss, the pressure drop, the pump power consumption and the supply temperatures of the district heating network were discussed. Besides, the operational issues of the integrated system were also researched. Several useful conclusions were drawn. It was found that a lower design primary supply temperature of the district heating network would give a higher seasonal energy efficiency of the integrated system throughout the whole heating season. Moreover, it was not always right to relate low design

  13. Heat supply concept for trade. Vol. 3. Environmentally friendly and energy-saving heat supply for public institutions by private operator models (phase 1). Final report. Vol. 2; Waermelieferungskonzept des Handwerks. Bd. 3. Umweltfreundliche und energiesparende Waermeversorgung oeffentlicher Einrichtungen durch private Betreibermodelle (Phase 1). Abschlussbericht. Berichtsband 2

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, J [ed.; Biermann, J; Locke, R; Meyer, K

    1991-01-01

    Volume 2 of this report indicates two goals: (3): Development and implementation of concrete heat supply models for public facilities in Berlin; (4): Development of models for cooperation between the heat utility and Berlin trade enterprises. (HW) [Deutsch] Der Berichtsband 2 weist 2 Teilziele auf: Teilziel 3: Erarbeitung und Gestaltung konkreter Waermelieferungsmodelle fuer oeffenliche Einrichtungen in Berlin; Teilziel 4: Gestaltung von Kooperationsmoeglichkeiten zwischen Waermeversorgungsgesellschaft und Handwerksbetrieben in Berlin. (HW)

  14. Condensing and water supplying systems in an atomic power plant

    International Nuclear Information System (INIS)

    Shinmura, Akira.

    1975-01-01

    Object: To reduce heat loss and eliminate accumulation of drain in water supplying and heating units in an atomic power plant by providing a direct contact type drain cooler between a gland-exhauster vapor condenser and a condensing and de-salting means, the drain from each water supplying and heating unit being collected in said cooler for heating the condensed water. Structure: Condensed water from a condenser is fed by a low pressure condensing pump through an air ejector and gland-exhauster vapor condenser to the direct-contact type drain cooler and is condensed in each water supply heater. Next, it is heated by drain fed through a drain level adjuster valve and an orifice and then forced by a medium pressure condenser pump into the condensing and de-salting means. It is then supplied by a high pressure condensing pump into the successive water supply heater. (Kamimura, M.)

  15. Integration of Space Heating and Hot Water Supply in Low Temperature District Heating

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Ommen, Torben Schmidt; Markussen, Michael

    2014-01-01

    pipes, where the water is at the highest temperature. The heat loss may be lowered by decreasing the temperatures in the network for which reason low temperature networks are proposed as a low loss solution for future district heating. However, the heating demand of the consumers involve both domestic......District heating makes it possible to provide heat for many consumers in an efficient manner. In particular, district heating based on combined heat and power production is highly efficient. One disadvantage of district heating is that there is a significant heat loss from the pipes...... to the surrounding ground. In larger networks involving both transmission and distribution systems, the heat loss is most significant from the distribution network. An estimate is that about 80-90 % of the heat loss occurs in the distribution system. In addition, the heat loss is naturally highest from the forward...

  16. Economy and development of heating station enterprises managed by forest owners; Metsaenomistajien laempoeyrittaemisen talous ja kehittaeminen

    Energy Technology Data Exchange (ETDEWEB)

    Tuomi, S [Work Efficiency Inst., Rajamaeki (Finland)

    1997-12-01

    Private heating enterprises are a new form of heat generation for municipalities in Finland. In this type the entrepreneur acquires the fuel and takes care of the operation and monitoring of the heating station. The recompense is paid on the basis of the heat amount produced to avoid problems related to i.e. the energy content and quality of the fuel. The price of heat is typically bound with that of light fuel oil. Agreements based on the price development of district heat and chips are also used. In 1996 there were 36 such heating enterprises in operation in Finland, their total efficiency being 11.5 MW. The aim of the project is to improve the feasibility of various forms of heating enterprises and to start new heating enterprises. The feasibility is studied both from the viewpoint of the entrepreneur and the municipality. The feasibility is improved by developing production chains of heating enterprises and the operability of the heating stations. Establishment of new heating enterprises is promoted by producing and disseminating information to possible entrepreneurs and municipalities. (orig.)

  17. Cooling and heating facility for nuclear power plant

    International Nuclear Information System (INIS)

    Kakuta, Atsuro

    1994-01-01

    The present invention concerns a cooling and heating facility for a nuclear power plant. Namely, a cooling water supply system supplies cooling water prepared by a refrigerator for cooling the inside of the plant. A warm water supply system supplies warm water having its temperature elevated by using an exhausted heat from a reactor water cleanup system. The facility comprises a heat pump-type refrigerator disposed in a cold water supply system for producing cold water and warm water, and warm water pipelines for connecting the refrigerator and the warm water supply system. With such a constitution, when the exhaust heat from the reactor water cleanup system can not be used, warm water prepared by the heat pump type refrigerator is supplied to the warm water supply system by way of the warm water pipelines. Accordingly, when the exhaust heat from the reactor water cleanup system can not be used such as upon inspection of the plant, a portion of the refrigerators in a not-operated state can be used for heating. Supply of boiler steams in the plant is no more necessary or extremely reduced. (I.S.)

  18. Localizing Climate Information for Municipal Planning in the Central U.S.

    Science.gov (United States)

    Shulski, M.; Umphlett, N.; Abdel-Monem, T.; Tang, Z.; Uhlarik, F.

    2017-12-01

    The impacts of projected climate change are an ongoing concern for municipalities. Planning at the local level often involves investigations of multiple hazards on decadal timescales. Of particular interest to cities are implications of too much or too little water, snow storms, heat waves, and freeze/thaw cycles on infrastructure, health, energy demands and water quality and availability. A two-year project led by the University of Nebraska - Lincoln has brought together scientist and stakeholder for the purpose of informing municipal planning and climate adaptation for 12 cities in the lower Missouri River Basin states (IA, NE, KS, MO). City-specific climate reports have been developed with municipal input to aid local planning efforts. Surveys to assess municipal climate data usage were distributed to all cities with a population greater than 5,000 in the four-state region. In addition, planning efforts for 18 municipalities have been evaluated for nearly 20 cities in the region to investigate local hazard mitigation, emergency, and comprehensive plans. This presentation will outline key outcomes of the project and discuss decision support tools developed in co-production with city planners.

  19. The State of Water and Wastewater Management in the Municipalities of the Polesie National Park

    Directory of Open Access Journals (Sweden)

    Krzysztof Jóżwiakowski

    2017-11-01

    Full Text Available The aim of the work is to present the current state of water and wastewater management in the municipalities where the Polesie National Park (PNP is located. The PNP is situated in Lublin Voivodeship, in the area of six municipalities: Sosnowica, Hańsk, Urszulin, Stary Brus, Wierzbica and Ludwin. The data used in this paper, were obtained on the basis of the surveys conducted in these municipalities in 2016 by the Department of Environmental Engineering and Geodesy of the University of Life Sciences in Lublin. In the analyzed communes, there was a very large disproportion between the usage of sewerage and the water supply network. It has been shown that 79.1% of the inhabitants living in the afore-mentioned communes used the water supply network and only 22.5% of them used sewerage. In the discussed communities there are 9 collective, mechanical and biological wastewater treatment plants with a capacity of over 5 m3d-1. On the farms located in the scattered areas, which are not connected to the sewerage, wastewater is discharged mainly to the septic tanks. In four out of the six analyzed municipalities, there were 2345 septic tanks registered. Domestic sewage from some farms is purified in household wastewater treatment plants (395 pieces. The plants with the drainage systems are prevalent (84.9%, which may contribute to the groundwater quality degradation. In order to protect the natural environment within the communes that form the PNP, it is necessary to undertake the actions that will contribute to the improvement of the current state of water and wastewater management. While solving the existing problems related to water supply and wastewater treatment, it is strongly required to adhere to the principle of sustainable development and use highly effective systems in order to ensure that the ecological effects are appropriate.

  20. Ultraviolet disinfection of treated municipal wastewaters

    Energy Technology Data Exchange (ETDEWEB)

    Vander Laan, H; Cairns, B

    1993-12-31

    A wastewater disinfection system developed by a Canadian company, Trojan Technologies Inc., was discussed. Disinfection for pathogen reduction prior to discharge of treated municipal wastewater back into rivers and lakes has been either ignored or treated by the use of chemicals. In 1979 the first pilot ultraviolet (UV) wastewater disinfection system was established. Since then, over 500 municipal UV installations have been commissioned. The largest installation can process 212 million gallons of water per day. The advantages of UV as a disinfectant are: (1) It is more effective than chlorine. (2) There are no mutagenic/carcinogenic byproducts formed with UV. (3) No toxic chemical residuals are discharged. (4) UV is safe to both the operators and the public. (5) It is cost effective. Europe has not been as active in wastewater disinfection as has North America. One result of the absence of wastewater disinfection in Europe is that the Rhine River, for example, carries 50 million salmonella per second. Disinfection of wastewater effluents is, of course, indispensable in protecting our drinking water supply. 2 figs.

  1. Computer control of the high-voltage power supply for the DIII-D electron cyclotron heating system

    International Nuclear Information System (INIS)

    Clow, D.D.; Kellman, D.H.

    1992-01-01

    This paper reports on the DIII-D Electron Cyclotron Heating (ECH) high voltage power supply which is controlled by a computer. Operational control is input via keyboard and mouse, and computer/power supply interfact is accomplished with a Computer Assisted Monitoring and Control (CAMAC) system. User-friendly tools allow the design and layout of simulated control panels on the computer screen. Panel controls and indicators can be changed, added or deleted, and simple editing of user-specific processes can quickly modify control and fault logic. Databases can be defined, and control panel functions are easily referred to various data channels. User-specific processes are written and linked using Fortran, to manage control and data acquisition through CAMAC. The resulting control system has significant advantages over the hardware it emulates: changes in logic, layout, and function are quickly and easily incorporated; data storage, retrieval, and processing are flexible and simply accomplished; physical components subject to wear and degradation are minimized. In addition, the system can be expanded to multiplex control of several power supplies, each with its own database, through a single computer console

  2. A municipal guide to least cost utility planning

    International Nuclear Information System (INIS)

    1992-03-01

    The recent track record of ''traditional'' electricity planning, which entails selection of supply side resources to meet forecasted demand, has not been good. There are numerous examples of utilities incorrectly forecasting demand and over-building generating capacity while others underestimated growth and have had to cut demand and find alternate power sources to avoid outages. A potential solution to this problem is the continuing development of Least Cost Utility Plannning (LCUP). Regulatory commissions, consumer advocates and utilities are increasingly relying an LCUP as the most responsible way to avoid construction of new capacity and alleviate anticipated shortages caused by cancellation of construction projects, load growth, or natural replacement of aging capacity. The purpose of this report is to provide municipalities a starting point for evaluating their servicing utilities or states' least cost plan. This was accomplished by: Identifying key issues in LCUP; reviewing examples of the collaborative and classic approaches to LCUP in Illinois, California, New York State and Michigan; cataloging municipal authorities and strategies which can influence or support LCUP activities. Results of the project indicate that through a basic understanding of LCUP processes and issues, municipalities will be in a better position to influence plans or, if necessary, intervene in regulatory proceedings where plans are adopted. Constraints to municipal involvement in LCUP include statutory limitations, resource constraints, and a lack of knowledge of indirect authorities that support the LCUP process

  3. A municipal guide to least cost utility planning

    Energy Technology Data Exchange (ETDEWEB)

    1992-03-01

    The recent track record of ``traditional`` electricity planning, which entails selection of supply side resources to meet forecasted demand, has not been good. There are numerous examples of utilities incorrectly forecasting demand and over-building generating capacity while others underestimated growth and have had to cut demand and find alternate power sources to avoid outages. A potential solution to this problem is the continuing development of Least Cost Utility Plannning (LCUP). Regulatory commissions, consumer advocates and utilities are increasingly relying an LCUP as the most responsible way to avoid construction of new capacity and alleviate anticipated shortages caused by cancellation of construction projects, load growth, or natural replacement of aging capacity. The purpose of this report is to provide municipalities a starting point for evaluating their servicing utilities or states` least cost plan. This was accomplished by: Identifying key issues in LCUP; reviewing examples of the collaborative and classic approaches to LCUP in Illinois, California, New York State and Michigan; cataloging municipal authorities and strategies which can influence or support LCUP activities. Results of the project indicate that through a basic understanding of LCUP processes and issues, municipalities will be in a better position to influence plans or, if necessary, intervene in regulatory proceedings where plans are adopted. Constraints to municipal involvement in LCUP include statutory limitations, resource constraints, and a lack of knowledge of indirect authorities that support the LCUP process.

  4. A municipal guide to least cost utility planning

    Energy Technology Data Exchange (ETDEWEB)

    1992-03-01

    The recent track record of traditional'' electricity planning, which entails selection of supply side resources to meet forecasted demand, has not been good. There are numerous examples of utilities incorrectly forecasting demand and over-building generating capacity while others underestimated growth and have had to cut demand and find alternate power sources to avoid outages. A potential solution to this problem is the continuing development of Least Cost Utility Plannning (LCUP). Regulatory commissions, consumer advocates and utilities are increasingly relying an LCUP as the most responsible way to avoid construction of new capacity and alleviate anticipated shortages caused by cancellation of construction projects, load growth, or natural replacement of aging capacity. The purpose of this report is to provide municipalities a starting point for evaluating their servicing utilities or states' least cost plan. This was accomplished by: Identifying key issues in LCUP; reviewing examples of the collaborative and classic approaches to LCUP in Illinois, California, New York State and Michigan; cataloging municipal authorities and strategies which can influence or support LCUP activities. Results of the project indicate that through a basic understanding of LCUP processes and issues, municipalities will be in a better position to influence plans or, if necessary, intervene in regulatory proceedings where plans are adopted. Constraints to municipal involvement in LCUP include statutory limitations, resource constraints, and a lack of knowledge of indirect authorities that support the LCUP process.

  5. A portable backup power supply to assure extended decay heat removal during natural phenomena-induced station blackout

    International Nuclear Information System (INIS)

    Proctor, L.D.; Merryman, L.D.; Sallee, W.E.

    1989-01-01

    The High Flux Isotope Reactor (HFIR) is a light water cooled and moderated flux-trap type research reactor located at Oak Ridge National Laboratory (ORNL). Coolant circulation following reactor shutdown is provided by the primary coolant pumps. DC-powered pony motors drive these pumps at a reduced flow rate following shutdown of the normal ac-powered motors. Forced circulation decay heat removal is required for several hours to preclude core damage following shutdown. Recent analyses identified a potential vulnerability due to a natural phenomena-induced station blackout. Neither the offsire power supply nor the onsite emergency diesel generators are designed to withstand the effects of seismic events or tornadoes. It could not be assured that the capacity of the dedicated batteries provided as a backup power supply for the primary coolant pump pony motors is adequate to provide forced circulation cooling for the required time following such events. A portable backup power supply added to the plant to address this potential vulnerability is described

  6. Energy and exergy analysis of low temperature district heating network

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    2012-01-01

    is designed to supply heating for 30 low energy detached residential houses. The network operational supply/return temperature is set as 55 °C/25 °C, which is in line with a pilot project carried out in Denmark. Two types of in-house substations are analyzed to supply the consumer domestic hot water demand...... energy/exergy losses and increase the quality match between the consumer heating demand and the district heating supply.......Low temperature district heating with reduced network supply and return temperature provides better match of the low quality building heating demand and the low quality heating supply from waste heat or renewable energy. In this paper, a hypothetical low temperature district heating network...

  7. Ohmic heating coil power supply using thyristor circuit breaker in a thermonuclear fusion device

    International Nuclear Information System (INIS)

    Tani, Keiji; Shimada, Ryuichi; Tamura, Sanae; Yabuno, Kohei; Koseki, Shoichiro.

    1982-01-01

    In a large scale Tokamak thermonuclear fusion device such as the critical plasma testing facility (JT60) presently under construction, mechanical breakers such as vacuum and air breakers are mostly used for interrupting DC heavy current which is supplied to the ohmic heating coils of inductive energy accumulation method. The practical use of the DC breakers employing thyristors has just been started because the history of thyristor development is short and thristors are still expensive, in spite of the advantages. In this paper, the circuit is investigated in which the excellent high speed controllability of thyristors is fully utilized, while the economy is taken into accout, and the experiment carried out with a unit model is described. It was found that a thyristor switch, which was constructed by connecting the high speed thyristors of peak off-state voltage rating 2,000 V and mean current rating 500 A in direct parallel, was able to interrupt 12.7 kA current in the power supply circuit of ohmic heating coils developed this time. In addition, the switch configuration was able to be greatly simplified. When the multistage raising of plasma current is required, the raise can be performed with a single thyristor breaker because it can make high speed control. Therefore, the capacity of the breaker can be doubly and drastically reduced. Also, if current unbalance might occur between thyristor switch units, it gives no problem since the time of reverse voltage after current interruption dispersed smaller as current increased. (Wakatsuki, Y.)

  8. Sustainable energy supply for mushroom cultivation. Application of underground energy storage. Application of a heat pump for heat production. Feasibility study; Duurzame energievoorziening paddestoelen kwekerij. toepassing van energieopslag in de bodem. Toepassing van warmtepomp voor warmteopwekking. Een haalbaarheidsstudie

    Energy Technology Data Exchange (ETDEWEB)

    Koel, J.J. [EBS-Adviseurs, Veenendaal (Netherlands)

    2001-02-26

    The results of a feasibility study on the use of heat and cold storage and the use of an electric heat pump for the energy supply of a mushroom cultivation business (Verbruggen paddestoelen in Erp, Netherlands) are presented.

  9. Exploitation of the geothermal potentials for the heat supply of the capital city; Erschliessung des geothermischen Potenzials fuer die Waermeversorgung der Hauptstadt

    Energy Technology Data Exchange (ETDEWEB)

    Bredel-Schuermann, Stefan [Berliner Gaswerke (GASAG)-AG, Berlin (Germany); Stiller, Manfred; Bauer, Klaus; Ryberg, Trond; Spalek, Angela; Huenges, Ernst [GeoForschungsZentrum Potsdam (Germany)

    2011-10-15

    Renewable energy sources currently are applied for the heat supply of Berlin only to 2%. The supply concept for the CO{sub 2} neutral city quarter at the Gasometer Schoeneberg provides for use of deep geothermal energy. An annual gross heat demand of nearly 7,000 MWh as well as a cooling requirement of nearly 5,000 MWh are expected for the site with scientific institutions, offices and restaurants.With the support of the GFZ German Research Centre for Geosciences (Potsdam, Federal Republic of Germany), the project partners GASAG Berliner Gaswerke Aktiengesellschaft (Berlin, Federal Republic of Germany) and EUREF AG (Berlin, Federal Republic of Germany) have performed first measurements in order to explore the geothermal potential of the capital city.

  10. Conversion to biofuel based heating systems - local environmental effects

    International Nuclear Information System (INIS)

    Jonsson, Anna

    2003-01-01

    One of the most serious environmental problems today is the global warming, i.e.climate changes caused by emissions of greenhouse gases. The greenhouse gases originate from combustion of fossil fuels and changes the atmospheric composition. As a result of the climate change, the Swedish government has decided to make a changeover of the Swedish energy system. This involves an increase of the supply of electricity and heating from renewable energy sources and a decrease in the amount electricity used for heating, as well as a more efficient use of the existing electricity system. Today, a rather large amount electricity is used for heating in Sweden. Furthermore, nuclear power will be phased out by the year 2010 in Sweden. Bio fuels are a renewable energy source and a conceivable alternative to the use of fossil fuels. Therefore, an increase of bio fuels will be seen the coming years. Bio fuels have a lot of environmental advantages, mainly for the global environment, but might also cause negative impacts such as depletion of the soils where the biomass is grown and local deterioration of the air quality where the bio fuels are combusted. These negative impacts are a result of the use of wrong techniques and a lack of knowledge and these factors have to be improved if the increase of the use of bio fuels is to be made effectively. The aim of this master thesis is to evaluate the possibilities for heating with bio fuel based systems in housing areas in the municipalities of Trollhaettan, Ulricehamn and Goetene in Vaestra Goetalands County in the South West of Sweden and to investigate which environmental and health effects are caused by the conversion of heating systems. The objective is to use the case studies as examples on preferable bio fuel based heating systems in different areas, and to what environmental impact this conversion of heating systems might cause. The housing areas for this study have been chosen on the basis of present heating system, one area

  11. Heat Roadmap Europe

    DEFF Research Database (Denmark)

    Connolly, David; Lund, Henrik; Mathiesen, Brian Vad

    2014-01-01

    compared to 1990 levels. None of these scenarios involve the large-scale implementation of district heating, but instead they focus on the electrification of the heating sector (primarily using heat pumps) and/or the large-scale implementation of electricity and heat savings. In this paper, the potential...... for district heating in the EU between now and 2050 is identified, based on extensive and detailed mapping of the EU heat demand and various supply options. Subsequently, a new ‘district heating plus heat savings’ scenario is technically and economically assessed from an energy systems perspective. The results...... indicate that with district heating, the EU energy system will be able to achieve the same reductions in primary energy supply and carbon dioxide emissions as the existing alternatives proposed. However, with district heating these goals can be achieved at a lower cost, with heating and cooling costs...

  12. The electrohydraulic balance of the solar heat storage with autonomous power supply

    Directory of Open Access Journals (Sweden)

    M. K. Marahtanov

    2014-01-01

    Full Text Available The introduction of the paper emphasizes an increasingly important role of alternative power sources nowadays. At the same time, a solar collector (suntrap is one of the most frequent techniques to use the solar energy. It is an absorber that picks up solar radiation and heats a heat carrier circulating in the close loop. Then the heat is transferred to the heat accumulator that is integrated in the hot-tap water system (HWS.The paper presents a prospective circuit of the solar collector. It differs from the traditional one because, in addition to absorbing panel, it uses photoconverters to generate electric power for the circulating pump. The advantage of this system is that for operation such a solar energy converter has no need in external power sources, i.e. it is autonomous. The need to calculate the essential thermo-physical parameters that ensure no-break system operation was stated as a main objective of the work.The suggested circuit has a photocell panel to convert solar radiation into dc voltage of 12 V. In case of a lack of the solar energy an accumulator battery can be used for feeding. To ensure the no-break supply of power an adaptor is offered.To calculate a density distribution of solar radiation a sine law is offered depending on the time of day and geographical locality. This dependence was used to obtain the expressions for calculating the water temperature in boiler over daytime.Further, the calculations have been done for the operating conditions under which an efficient heat exchange will be provided with the minimum consumption of electric power for the heat carrier circulation in the first loop. For this purpose, a pump power was calculated depending on consumption and hydraulic losses of head in the pipeline. As a minimum required consumption the value has been chosen at which a laminar flow regime changes to the turbulent one because of the most efficient heat exchange being both in collector and in heat accumulator

  13. Fiscal 1976 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system; 1976 nendo taiyonetsu reidanbo kyuto system no kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-03-01

    This report describes the fiscal 1974-76 research result on solar cooling/heating and hot water supply systems. Research was made on survey and analysis of current R and D states, system analysis, energy impact analysis, installation sites of solar collectors, diffusion policy, profitability, and performance evaluation method. Main research results obtained are as follows. The effect of solar cooling/heating and hot water supply on the Japanese energy demand in 2000 is estimated to be 13% for residences and 5% for the other buildings. Environment pollution derived from solar cooling/heating is extremely less than that from conventional energy quantitatively. The facility cost is estimated to be probably 27,000yen/m{sup 2} in collector cost, and nearly 100,000yen/t in heat storage tank cost. As design data for solar cooling/heating systems, the estimation method of heat collection for every solar radiation rank, performance comparison of honeycomb type collectors, and various data for air heat collection systems are presented. (NEDO)

  14. Estimation of efficiency of the heat supply system based on a boiler house and a wind turbine in the northern environment

    Science.gov (United States)

    Bezhan, A. V.; Minin, V. A.

    2017-03-01

    This article describes a methodological approach to defining indoor air temperature in buildings heated by a power supply unit consisting of a boiler house and a wind-driven power plant (WDPP). We discuss a heating option for a residential building in the windy conditions of Murmansk city. We proved that, during the periods of strong wind, a WDPP can partially or fully satisfy the heat demand and sometimes even create a surplus of energy. During low wind weather, almost all loads are handled by the boiler house. We considered a possibility to accumulate the surplus energy obtained from a WDPP during strong wind by increasing the temperature in the whole building up to 25°C and further using the accumulated heat during the lowwind period when indoor air temperature may fall below 20°C. This allows saving organic fuel in the boiler house. We demonstrated how indoor air temperature in the building may change throughout the year when using the surplus energy from the WDPP due to thermal storage capacitance of the building. We also provided the results of study, showing favorable energy-related effects of using a WDPP along with the boiler house. It was determined that engaging a WDPP in fulfilling the diagram of heating loads promotes the decrease in the boiler house's contribution to heat supply by 30 to 50%, and using the surplus energy from the WDPP and thermal storage capacitance of the building allows reducing the contribution of the boiler house by 5-15% more in certain months.

  15. An experimental study of the enhanced heating capacity of an electric heat pump (EHP) using the heat recovered from a gas engine generator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Cheol Min; Chang, Se Dong [HAC R and D Laboratory, LG Electronics, 327-23 Gasan-Dong, Geumcheon-gu, Seoul 153-802 (Korea); Lee, Jaekeun; Hwang, Yujin [School of Mechanical Engineering, Pusan National University, San 30, Changjeon-Dong, Keumjeong-Ku, Busan 609-735 (Korea)

    2009-11-15

    This paper is concerned with the effect of recovered heat on the heating capacity of an Electric Heat Pump (EHP), which is supplied with electric power and recovered heat from a gas engine generator system. Two methods of supplying recovery heat are examined: (i) to the refrigerant with the discharge line heat exchanger (HEX), and (ii) to the refrigerant of the evaporator with the sub-evaporator. Heating capacity, input power and coefficient of performance (COP) were investigated and compared for each heat recovery method. Conclusively, we found that the second method was most reasonable to recover wasted heat and increased system COP by 215%. (author)

  16. Conflict nuclear power. Theses for current supply with and without nuclear power

    International Nuclear Information System (INIS)

    Schwarz, E.

    2007-01-01

    requires new participants such as industrial companies, industrial concerns, municipalities and private people. In order to progress the development of the renewable energies, the renewable energy law must remain unchanged for longer time. One of the most efficient technologies for the reduction of carbon dioxide is the simultaneous generation of power and heat by means of combined heat and power generation. The demand to dispense with coal and to use natural gas instead of coal, ha a wrong idea about the delivery risks and price risks of the gas supply and increases the dependence from imports. The technology of the separation and storage of carbon dioxide is not necessary, in order to reach a reduction of the carbon dioxide from 80 % to the year 2050. Due to the environmental sequences and climatic sequences connected with the power generation electricity should be used rationally. The change of the German national economy requires the dismantling of unnecessary current consumption, the development of the combined heat and power generation and the development of renewable energies

  17. Resource recovery from municipal solid waste by mechanical heat treatment: An opportunity

    Science.gov (United States)

    Kamaruddin, Mohamad Anuar; Yusoff, Mohd Suffian; Ibrahim, Nurazim; Zawawi, Mohd Hafiz

    2017-04-01

    Municipal solid waste (MSW) stream in Malaysia consists of 50 to 60 % of food wastes. In general, food wastes are commingled in nature and very difficult to be managed in sustainable manner due to high moisture content. Consequently, by dumping food wastes together with inert wastes to the landfill as final disposal destination incurs large space area and reducing the lifespan of landfill. Therefore, certain fraction of the MSW as such; food wastes (FW) can be diverted from total disposal at the landfill that can improve landfill lifespan and environmental conservation. This study aims to determine the resource characteristics of FW extracted from USM cafeteria by means of mechanical heat treatment in the presence of autoclaving technology. Sampling of FW were conducted by collecting FW samples from disposal storage at designated area within USM campus. FW characteristics was performed prior and autoclaving process. The results have demonstrated that bones fraction was the highest followed by vegetable and rice with 39, 27 and 10%, respectively. Meanwhile, based on autoclaving technique, moisture content of the FW (fresh waste) were able to be reduced ranging from 65-85% to 59-69% (treated waste). Meanwhile, chemical characteristics of treated FW results in pH, TOC, TKN, C/N ratio, TP, and TK 5.12, 27,6%, 1.6%, 17.3%, 0.9% and 0.36%. The results revealed that autoclaving technology is a promising approach for MSW diversion that can be transformed into useful byproducts such as fertilizer, RDF and recyclable items.

  18. Special considerations on operating a fuel cell power plant using natural gas with marginal heating value

    Energy Technology Data Exchange (ETDEWEB)

    Moses, L. Ng; Chien-Liang Lin [Industrial Technology Research Institute, Taiwan (China); Ya-Tang Cheng [Power Research Institute, Taiwan (China)

    1996-12-31

    In realizing new power generation technologies in Taiwan, a phosphoric acid fuel cell power plant (model PC2513, ONSI Corporation) has been installed in the premises of the Power Research Institute of the Taiwan Power Company in Taipei County of Taiwan. The pipeline gas supplying to the site of this power plant has a high percentage of carbon dioxide and thus a slightly lower heating value than that specified by the manufacturer. Because of the lowering of heating value of input gas, the highest Output power from the power plant is understandably less than the rated power of 200 kW designed. Further, the transient response of the power plant as interrupted from the Grid is also affected. Since this gas is also the pipeline gas supplying to the heavily populated Taipei Municipal area, it is conceivable that the success of the operations of fuel cells using this fuel is of vital importance to the promotion of the use of this power generation technology in Taiwan. Hence, experiments were set up to assess the feasibility of this fuel cell power plant using the existing pipeline gas in this part of Taiwan where fuel cells would most likely find useful.

  19. Designing a Municipality

    DEFF Research Database (Denmark)

    Jungersen, Ulrik; Hansen, Poul H. Kyvsgård

    2014-01-01

    Can a municipality be designed? The municipality Kolding in the southern part of Denmark asked this question. The idea emerged as a response to a recognized need for new ways of branding and developing the municipality. It is an ongoing process that was kicked off in 2012 and this paper is theref......Can a municipality be designed? The municipality Kolding in the southern part of Denmark asked this question. The idea emerged as a response to a recognized need for new ways of branding and developing the municipality. It is an ongoing process that was kicked off in 2012 and this paper...... is therefore focusing primarily on the process of changing the perception of how to organize development in a municipality. The most important elements in transforming the whole development setup are described. Finally, a short case describing one of the significant results is included....

  20. Energy in the focus. Potentials and challenges of the municipal water management and wastewater management; Energie im Fokus. Potenziale und Herausforderungen der kommunalen Wasser- und Abwasserwirtschaft

    Energy Technology Data Exchange (ETDEWEB)

    Benz, Philipp [EWE Wasser GmbH, Oldenburg (Germany); Blotenberg, Ute [Muenchner Stadtentwaesserung, Muenchen (Germany); Eimer, Bernhard [Berliner Wasserbetriebe AoeR, Berlin (Germany)] [and others

    2012-11-15

    The supply of water and the sewage disposal are energy-intensive tasks of the municipal general interest. The brochure under consideration is the result of the VKU working group ''Energy efficiency in the water management''. Municipal companies exploit the present potentials of energy efficiency by means of a purely technical maintenance continuously and target-oriented. With this, the water suppliers and sewerage providers document their intention to optimise the plant operation continuously and to increase the yield of the internal energy without legal target values. An implementation in superordinated municipal energy concepts may be useful as long as the core task drinking water supply and sewage disposal have priority.

  1. ACCOUNTING FOR NONUNIFORMITY OF WATER CONSUMPTION IN THE EXHAUST AIR HEAT RECLAMATION SYSTEMS FOR HOT WATER SUPPLY

    Directory of Open Access Journals (Sweden)

    Samarin Oleg Dmitrievich

    2017-03-01

    Full Text Available This article is devoted to assessment of the influence of variation of daily hot water consumption on the predicted energy effect by using heat recovery of exhaust air in typical exhaust ventilation systems of the most commonly used flat buildings during their switch to the mechanical induction for the pre-heating of water for hot water supply. It outlines the general principle of the organization of this method of energy saving and presents the basic equations of heat transfer in the heat exchanger. The article proposes a simplified method of accounting for changes in the heat transfer coefficient of air-to-water heat exchanger with fluctuations of water demand using existing dependencies for this coefficient from the rate flow of heating and heated fluid through the device. It presents observations to identify the parameters of the real changes of water consumption during the day with the main quantitative characteristics of normally distributed random variables. Calculation of thermal efficiency of the heat exchange equipment using dimensionless parameters through the number of heat transfer under the optimal opposing scheme of fluid motion is completed under conditions of variable water flow rate for the type residential building of the П3-1/16 series using the Monte Carlo method for numerical modeling of stochastic processes. The estimation of the influence of fluctuation of the current water consumption on the instantaneous thermal efficiency factor of the heat exchanger and the total energy consumption of the building is given, and it is shown that the error of said calculation using average daily parameters is within the margin of usual engineering calculation.

  2. Heating a school by means of waste heat from an ice hall

    International Nuclear Information System (INIS)

    2001-01-01

    As the first building in Norway, Gimle school in Halden can be heated by means of a special combination system that gives up waste heat from a nearby ice hall and earth heat. This system will reduce the expenses of the municipality with the equivalent of USD 30 000 per year, or 618 000 kWh. 308 000 kWh comes from the refrigeration plant of the ice hall and 310 000 kWh from the ground. Although the system is both environmentally friendly end energy conserving, financial state support has been refused

  3. Managed groundwater development for water-supply security in Sub ...

    African Journals Online (AJOL)

    What is the scope for promoting much increased groundwater use for irrigated agriculture, and how might the investment risks be reduced and sustainable outcomes ensured? • How can the demand to expand urban groundwater use, for both further supplementing municipal water-supply systems and for direct in situ water ...

  4. Industrial water supply for the Kursk TETs-1 heating and electric power plant with the ecological safety of the River Seim taken into account

    International Nuclear Information System (INIS)

    Kyakk, V. A.

    2009-01-01

    The Kursk TETs-1 heating and electric power plant is discussed as an illustration of preventing thermal contamination of its water supply (River Seim) by circulating water. An effective water supply system is taken to be one for which the overheating of the water at a monitoring site (near the outlet location) does not exceed an approved level for the water use conditions. The required cooling capacity of a spray pond for circulating and flow-through water supplies is determined.

  5. Feasibility of geothermal heat use in the San Bernardino Municipal Wastewater Treatment Plant. Final report, September 1980-June 1981

    Energy Technology Data Exchange (ETDEWEB)

    Racine, W.C.; Larson, T.C.; Stewart, C.A.; Wessel, H.B.

    1981-06-01

    A system was developed for utilizing nearby low temperature geothermal energy to heat two high-rate primary anaerobic digesters at the San Bernardino Wastewater Treatment Plant. The geothermal fluid would replace the methane currently burned to fuel the digesters. A summary of the work accomplished on the feasibility study is presented. The design and operation of the facility are examined and potentially viable applications selected for additional study. Results of these investigations and system descriptions and equipment specifications for utilizing geothermal energy in the selected processes are presented. The economic analyses conducted on the six engineering design cases are discussed. The environmental setting of the project and an analysis of the environmental impacts that will result from construction and operation of the geothermal heating system are discussed. A Resource Development Plan describes the steps that the San Bernardino Municipal Water Department could follow in order to utilize the resource. A preliminary well program and rough cost estimates for the production and injection wells also are included. The Water Department is provided with a program and schedule for implementing a geothermal system to serve the wastewater treatment plant. Regulatory, financial, and legal issues that will impact the project are presented in the Appendix. An outline of a Public Awareness Program is included.

  6. Comparative study for endenergy supply with nuclear district heating and with nuclear long distance energy

    International Nuclear Information System (INIS)

    Dietrich, G.

    1975-07-01

    The future energy supply of the Federal Republic of Germany will be orientated to secure energy carriers. Moreover economical energy consumption and environmental protection will be a force for an increased application of district heating and nuclear long distance energy. The technics of generation, transport and distribution of the two energy carriers will be discussed, besides a short review of application areas and potentials. The cost comparisons by models show that there are special advantages for both systems. Nevertheless the conclusions from the study can be to favour nuclear long distance energy because of its wide application range in the whole heat market. But there is also the competition with combined heat and power generation on fossil basis, as practised in many industrial companies. As a result of a regional analysis of the area Aachen-Moenchengladbach-Koeln, the cost advantages of the nuclear long distance energy as a parameter of current prices are confirmed. Nuclear long distance energy, in combination with the high temperature reactor and a developed technic of catalysts up to temperatures of 900 K, is an energy source which will be independant of regional necessities, secure, non pollutant and economic. (orig.) [de

  7. Realisation of a small hydro power plant in the water supply of the Gudo municipality; Realizzazione di una microcentrale idroelettrica sulla condotta di adduzione tra le sorgenti Valle del Cugnolo e il serbatoio Sasso Grande - Studio di fattibilita

    Energy Technology Data Exchange (ETDEWEB)

    Mutti, M.

    2008-12-15

    This report for the Swiss Federal Office of Energy (SFOE) presents the feasibility study for the renewal of the drinking-water supply of the Gudo Municipality, Switzerland, including a new micro-scale power plant at the entrance of the main water reservoir. The water quantities available are listed. The investment cost is evaluated. The major cost arises from the replacement of the main pipe connecting the remote spring to the water reservoir by a penstock following a new lie. The project is technically feasible, but economically not. However, considering the age and actual status of the water supply, the authorities will anyway soon have to take adequate measures.

  8. Organic school meals in three Danish municipalities

    DEFF Research Database (Denmark)

    He, Chen; Mikkelsen, Bent Egberg

    In order to prevent children and young people from becoming obese, healthier eating patterns are urgent. Organic school meals may be an effective strategy to provide healthy food to children. The purpose of this study was to take a closer look into the current status of organic school meal systems...... in Denmark, by conducting a case study of three municipalities in the Zealand region that have the most developed models for school meals service in this country. These municipalities have for some years introduced organic food for sale in their primary schools, with three quite different approaches....... Copenhagen has established a large central kitchen, producing partly organic food that is heated and sold in tuck shops at the schools. Roskilde cooperates with an organic catering company, delivering food to be sold in school canteens. Gladsaxe has part-time employed staff preparing and selling food at each...

  9. Technologies for building integrated energy supply; Teknologier for bygningsintegreret energiforsyning

    Energy Technology Data Exchange (ETDEWEB)

    Katic, I.

    2011-07-15

    The current report is part of the deliverables from the project ''Building Integrated Energy Supply'' supported by the Danish Energy Authority R and D program. It describes a range of technologies for individual supply of heat and/or electricity to dwellings with respect to their stage of development and possible application in the near future. Energy supply of buildings is becoming more and more complex, partly as a result of increasing demands for comfort, efficiency and reduced emissions, partly as a result of rising oil prices and improved competitiveness of alternative energy sources. The days where ordinary boilers were the dominant source of individual supply of dwellings are becoming past these years. The challenge of the new range of technologies lies to a high extent in the fluctuating nature of their energy conversion and their interaction with the supply grids for heat and electricity. There is thus an increasing demand to understand the nature of the different supply technologies, besides a regular update of their economical key figures. The technologies briefly described in this study are: Solar heating, passive solar energy, biofuel boilers, heat pumps, micro CHP, solar photovoltaic and energy storage systems. The selected technologies are all assessed to play an important role in future's mix of supply technologies in Denmark, especially heat pumps and solar. (Author)

  10. Municipal Bonds in Developing Countries. Case Study: Municipality of Stip, Republic of Macedonia

    Directory of Open Access Journals (Sweden)

    Marija GOGOVA SAMONIKOV

    2017-06-01

    Full Text Available The developing countries, especially in the Balkans, barely use the municipal bonds as an alternative way of financing their activities. This paper is part of the project “The municipal bonds as an alternative source of financing municipals activities and the effective management of funds, with a special emphasis to the Municipality of Stip, R. Macedonia”. The paper has an important impact, according to both academic and practical perspective. It combines the experts’ academic analysis with the municipals potential in order to facilitate a successful municipal bond emission that would support the local economic growth. The purpose of this paper is to investigate the ability and willingness of the Municipality of Stip to issue municipal bonds. The main hypothesis states that the Municipality of Stip is able to issue a municipal bond as an alternative way of financing its investment activities. The research includes the classical SWOT analysis regarding the Municipality of Stip and continues with a statistical analysis based on correlation and regression relationships within the accounts of the Municipality’s annual reports. The methodological framework is based on quantitative research methods (correlations and regression methods which result in acceptance of the main hypothesis in the paper - the municipal bonds as an alternative source for funding municipal’s activities are justified, especially if the funds are associated with a specific revenue-generating project. The findings would serve as a basis for the municipal bonds prospect, which would be the ultimate goal of combining the academic knowledge with the practical potential of the Municipality of Stip. The conclusions reveal that this would be the first municipal bond emission in the Republic of Macedonia. However, this fact can serve as an advantage in the market in terms of introducing financial instrument innovation. This paper suggests that the usage of municipal bonds is

  11. Computer control of the high-voltage power supply for the DIII-D Electron Cyclotron Heating system

    International Nuclear Information System (INIS)

    Clow, D.D.; Kellman, D.H.

    1991-10-01

    The D3-D Electron Cyclotron Heating (ECH) high voltage power supply is controlled by a computer. Operational control is input via keyboard and mouse, and computer/power supply interface is accomplished with a Computer Assisted Monitoring and Control (CAMAC) system. User-friendly tools allow the design and layout of simulated control panels on the computer screen. Panel controls and indicators can be changed, added or deleted, and simple editing of user-specific processes can quickly modify control and fault logic. Databases can be defined, and control panel functions are easily referred to various data channels. User-specific processes are written and linked using Fortran, to manage control and data acquisition through CAMAC. The resulting control system has significant advantages over the hardware it emulates: changes in logic, layout, and function are quickly and easily incorporated; data storage, retrieval, and processing are flexible and simply accomplished, physical components subject to wear and degradation are minimized. In addition, the system can be expanded to multiplex control of several power supplied, each with its own database, through a single computer and console. 5 refs., 4 figs., 1 tab

  12. Development of advanced heat pump (2). Prelimirary test of two-stage compression heat pump. Koseino onreinetsu kyokyu heat pump system no kaihatsu. Dai 2 ho 2dan attsusyuku system shisakuki no yobi jikken kekka

    Energy Technology Data Exchange (ETDEWEB)

    Iwatsubo, Tetsushiro; Saikawa, Michinori; Hamamatsu, Teruhide

    1988-03-01

    A heat pump driven by electricity is one of the excellent electricity utilization systems and is promoted to be widely used. An advanced heat pump has been investigated to enlarge its applications in the field of hot water supply for domestic use which will be competitive with city gas and air conditioning in large scale buildings. An experimental unit with two-stage compression system was designed, which has the multi-function of air conditioning and hot water supply, and the trial system was fabricated. In the design, followings were considered; cooperative operations of two compressors by inverter driving, the temperature conditions of both the air for the air conditioning and the heat source, additional setting of the intermediate heat exchanger. The test operation was carried out with checking the start up procedure, the control sequence and so on. The probability of five operation modes: cooling, heating, hot water supply, cooling/hot water supply, and heating/hot water supply, were confirmed. In the mode of heating/hot water supply the hot water temperature was increased to 65/sup 0/C, the excellent performance in hot water supply was demonstrated. (21 figs, 8 tabs, 1 photo, 5 refs)

  13. Power supply in future: ecological aspects; Kuenftige Stromversorgung: Oekologische Aspekte

    Energy Technology Data Exchange (ETDEWEB)

    Hustedt, M.

    2000-06-01

    The most important prerequisites for an ecological supply of energy in the future is the opting out of nuclear energy and the completion of the second and third phase of the socio-ecological tax reform. As a part of our energy will continue to be generated on the basis of fossil fuels in the foreseeable future, it is essential that a radical change takes place in the efficiency of fossil energy engineering. In addition to this, any possible energy-saving potential must be exploited; this includes the new energy-saving law, promoting the modernisation of old buildings and modern energy management (heat insulation, heating engineering, warm water heating etc.). For an ecological power supply the share of renewable energies must be increased to form a major pillar of our power supply. The '100,000-roof' programme of the German federal government and the development programme for near-market renewable energy sources form part of this approach. Energy research should shift its orientation and accelerate the conversion of our power supply: priority should be given to developing energy-saving technologies and renewable energy. Supporting municipalities and public utilities is especially important. This means revising the basic conditions of energy laws so that they assist public utilities to face competition as power utilities. (orig.) [German] Wichtigste Voraussetzung fuer eine kuenftige oekologische Stromversorgung sind der Ausstieg aus der Atomenergie sowie die Vollendung der zweiten und dritten Stufe der oekologisch-sozialen Steuerreform. Da in absehbarer Zeit ein Teil der Energieerzeugung weiterhin auf Basis fossiler Energietraeger erfolgen wird, ist eine Effizienzrevolution bei den fossilen Energietechnologien notwendig. Darueber hinaus muessen die erschliessbaren Energieeinsparpotentiale genutzt werden; dazu gehoeren die neue Energiesparverordnung, die Foerderung der Altbausanierung sowie ein modernes Energiemanagement (Waermedaemmung

  14. Remunicipalisation and Foundation of Municipal Utilities in the German Energy Sector: Details about Newly Established Enterprises

    Directory of Open Access Journals (Sweden)

    Oliver Wagner

    2017-09-01

    Full Text Available Since the majority of network concession contracts in Germany were set to expire some time between 2005 and 2016, a window of opportunity arose in which to rebuild and remunicipalise the local energy supply. As a result, 72 new local power companies were established in Germany within the space of just seven years (between early 2005 and late 2012. This paper provides an introduction to the topic of establishing municipal utilities in Germany. The findings were identified on the basis of the comprehensive screening of all newly established municipal utilities in Germany. Our analysis provides information about regional concentration, the size of municipalities, the legal forms of the newly founded municipal public utilities and the role of strategic partnerships. The key findings are that remunicipalisation is not a question of size and that knowledge gaps may be closed by entering into close strategic partnerships.

  15. Load Management in District Heating Operation

    OpenAIRE

    Li, Hongwei; Wang, Stephen Jia

    2015-01-01

    Smooth operation of district heating system will avoid installation of expensive peak heat boilers, improve plant partial load performance, increase the system redundancy for further network expansion and improve its resilience to ensuresecurity of supply during severe heating seasons. The peak heating load can be reduced through building demand side management. The building thermal mass can be used to shift the heating supply under the circumstance withoutjeopardizing the consumer thermal co...

  16. Environmental impact of emissions from incineration plants in comparison to typical heating systems

    Science.gov (United States)

    Wielgosiński, Grzegorz; Namiecińska, Olga; Czerwińska, Justyna

    2018-01-01

    In recent years, five modern municipal waste incineration plants have been built in Poland. Next ones are being constructed and at the same time building of several others is being considered. Despite positive experience with the operation of the existing installations, each project of building a new incinerator raises a lot of emotions and social protests. The main argument against construction of an incineration plant is the emission of pollutants. The work compares emissions from municipal waste incineration plants with those from typical heating plants: in the first part, for comparison large heating plants equipped with pulverized coal-fired boilers (OP-140), stoker-fired boilers (three OR-32 boilers) or gas blocks with heat output of about 100 MW have been selected, while the second part compares WR-10 and WR-25 stoker-fired boilers most popular in our heating industry with thermal treatment systems for municipal waste or refuse-derived-fuel (RDF) with similar heat output. Both absolute emission and impact - immission of pollutants in vicinity of the plant were analyzed.

  17. Environmental impact of emissions from incineration plants in comparison to typical heating systems

    Directory of Open Access Journals (Sweden)

    Wielgosiński Grzegorz

    2018-01-01

    Full Text Available In recent years, five modern municipal waste incineration plants have been built in Poland. Next ones are being constructed and at the same time building of several others is being considered. Despite positive experience with the operation of the existing installations, each project of building a new incinerator raises a lot of emotions and social protests. The main argument against construction of an incineration plant is the emission of pollutants. The work compares emissions from municipal waste incineration plants with those from typical heating plants: in the first part, for comparison large heating plants equipped with pulverized coal-fired boilers (OP-140, stoker-fired boilers (three OR-32 boilers or gas blocks with heat output of about 100 MW have been selected, while the second part compares WR-10 and WR-25 stoker-fired boilers most popular in our heating industry with thermal treatment systems for municipal waste or refuse-derived-fuel (RDF with similar heat output. Both absolute emission and impact - immission of pollutants in vicinity of the plant were analyzed.

  18. Sami-speaking municipalities and a control group's access to somatic specialist health care (SHC): a retrospective study on general practitioners’ referrals

    Science.gov (United States)

    Norum, Jan; Nieder, Carsten

    2012-01-01

    Objectives The Sami people constitute the indigenous people in northern Norway. The objective of this study was to clarify whether they have a similar supply of somatic specialist health care (SHC) as others. Methods The referrals from general practitioners (GPs) in the primary health care (PHC) in the administration area of the Sami language law (8 municipalities) were matched with a control group of 11 municipalities. Population data was accessed from Statistics Norway and the time period 2007–2010 was analysed. The main outcome was the number of referrals per 1,000 inhabitants according to age group, gender and place of living. Results 504,292 referrals in northern Norway were indentified and the Sami and control group constituted 23,093 and 22,541 referrals, respectively. The major findings were a similar referral ratio (RR) (1.14 and 1.17) (p =0.624) and women more commonly referred (female/male ratio 1.45 and 1.41) in both groups. GPs in both groups were loyal to their local hospital trust. Conclusion Inhabitants in Sami-speaking municipalities in northern Norway have a similar supply of SHC services as controls. Inter-municipal variation was significant in both groups. PMID:22456052

  19. Sami-speaking municipalities and a control group's access to somatic specialist health care (SHC): a retrospective study on general practitioners' referrals.

    Science.gov (United States)

    Norum, Jan; Nieder, Carsten

    2012-03-19

    The Sami people constitute the indigenous people in northern Norway. The objective of this study was to clarify whether they have a similar supply of somatic specialist health care (SHC) as others. The referrals from general practitioners (GPs) in the primary health care (PHC) in the administration area of the Sami language law (8 municipalities) were matched with a control group of 11 municipalities. Population data was accessed from Statistics Norway and the time period 2007-2010 was analysed. The main outcome was the number of referrals per 1,000 inhabitants according to age group, gender and place of living. 504,292 referrals in northern Norway were indentified and the Sami and control group constituted 23,093 and 22,541 referrals, respectively. The major findings were a similar referral ratio (RR) (1.14 and 1.17) (p = 0.624) and women more commonly referred (female/male ratio 1.45 and 1.41) in both groups. GPs in both groups were loyal to their local hospital trust. Inhabitants in Sami-speaking municipalities in northern Norway have a similar supply of SHC services as controls. Inter-municipal variation was significant in both groups.

  20. TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    A. E. Denysova

    2017-09-01

    Full Text Available The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources have essential shortcomings: low power, ecological and economic efficiencies, that can be eliminated by using alternative methods of power supply, like the considered one: low-temperature natural heat of ground waters of on the basis of heat pump installations application. The heat supply system considered provides an effective use of two stages heat pump installation operating as heat source at ground waters during the lowest ambient temperature period. Proposed is a calculation method of heat pump installations on the basis of groundwater energy. Calculated are the values of electric energy consumption by the compressors’ drive, and the heat supply system transformation coefficient µ for a low-potential source of heat from ground waters allowing to estimate high efficiency of two stages heat pump installations.

  1. Fiscal 1999 basic research on promotion of joint implementation. Comprehensive feasibility study on efficiency improvement project for heat generation facilities and heat supply networks for district heating at districts in Moscow region, the Russian Federation (2 model districts within the region)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    For the purpose of conserving energy and reducing greenhouse gas, a survey is conducted for district heating facilities of the Khimki district and Voskresensk district in Moscow and for their heat supply networks. Four boilers existing at the Khimki district are all to be replaced by natural gas turbine centralized cogeneration plants, and four boilers existing at the Voskresensk district are all to be replaced by natural gas turbine cogeneration facilities. These projects are designated as Case 1 and Case 2, different from each other in terms of power generation capability and heat supply scale. As for investment, a total of 267-million dollars will be necessary for Case 1, and 208-million dollars for Case 2. As for energy conservation, energy will be saved by approximately 2.8-million tons in total in terms of oil in Case 1, and approximately 2-million tons in terms of oil in Case 2. As for greenhouse gas reduction, there will be a reduction of approximately 6.8-million tons in terms of CO2 in Case 1, and a reduction of approximately 4.9-million tons in terms of CO2 in Case 2. (NEDO)

  2. Municipal responses to the energy challenge: Metz, France and Saarbruecken, FRG

    Energy Technology Data Exchange (ETDEWEB)

    Woodward, A E

    1987-01-01

    This paper is one of a series investigating the social and organizational dynamics of municipal innovation in energy planning, conservation and supply. Germany and France offer strikingly different pre-conditions for local energy innovation. Germany, with its decentralized federal structure, provides a lot of leeway for local innovations, but little in the way of economic spurs, relying on the workings of the market system. France's highly centralized system can provide the latest information and national investment programs to spark local activities, but its centralized structure may also frustrate local initiative. This case study focuses on two communities who were among the front-runners in community energy innovation in France and West-Germany: Metz and Saarbruecken. Both share strong mayor systems and municipal utilities, two factors which provide the freedom and the power to quickly change energy approach. The impetus for change came from the political sphere. In a conclucing chapter, both cases are compared and contrasted. The two cases illuminate the possibilities and constraints of politically motivated energy innovation in municipalities.

  3. Water supply at Los Alamos during 1996. Progress report

    International Nuclear Information System (INIS)

    McLin, S.G.; Purtymun, W.D.; Maes, M.N.; Longmire, P.A.

    1997-12-01

    Production of potable municipal water supplies during 1996 totaled about 1,368.1 million gallons from wells in the Guaje, Pajarito, and Otowi well fields. There was no water used from either the spring gallery in Water Canyon or from Guaje Reservoir during 1996. About 2.6 million gallons of water from Los Alamos Reservoir was used for lawn irrigation. The total water usage in 1996 was about 1,370.7 million gallons, or about 131 gallons per day per person living in Los Alamos County. Groundwater pumpage was up about 12.0 million gallons in 1996 compared with the pumpage in 1995. This report fulfills requirements specified in US Department of Energy (DOE) Order 5400.1 (Groundwater Protection Management Program), which requires the Los Alamos National Laboratory (LANL) to monitor and document groundwater conditions below Pajarito Plateau and to protect the regional aquifer from contamination associated with Laboratory operations. Furthermore, this report also fulfills special conditions by providing information on hydrologic characteristics of the regional aquifer, including operating conditions of the municipal water supply system

  4. Heat networks in France in 2014. Heat networks: which price for the consumer?

    International Nuclear Information System (INIS)

    Reynaud, Didier; Gong, Zheng; Moreau, Sylvain; Bottin, Anne; Reperant, Patricia

    2016-04-01

    A first document publishes and comments various statistics regarding heat networks in France in 2014: distribution in terms of quantity of supplied heat, main urban units, distribution in terms of urban unit size and in terms of community type (land, isolated town, outskirts, centre town). It also indicates the types, percentages and evolution of energies consumed in these heat networks, the shares of fossil and renewable energies, and the distribution of networks in terms of energy type. Some regional data are briefly commented (energy shares in each region, number of primary housing connected to an urban heating network). This publication also indicates methodological aspects and the definitions of the main components and characteristics of a heat network. Notably based on some of these data, the second document comments the price of heat supplied in these heat networks in 2014 as these prices are not regulated and depend on agreements between clients and providers. These prices are analysed in terms of linear thermal density, of heat quantity supplied by delivery point, of sector (industry, housing, office building), of rate of renewable energy, and of operator status (public service delegation or private ownership)

  5. Heat pumps: heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Pielke, R

    1976-01-01

    The author firstly explains in a general manner the functioning of the heat pump. Following a brief look at the future heat demand and the possibilities of covering it, the various methods of obtaining energy (making use of solar energy, ground heat, and others) and the practical applications (office heating, swimming pool heating etc.) are explained. The author still sees considerable difficulties in using the heat pump at present on a large scale. Firstly there is not enough maintenance personnel available, secondly the electricity supply undertakings cannot provide the necessary electricity on a wide basis without considerable investments. Other possibilities to save energy or to use waste energy are at present easier and more economical to realize. Recuperative and regenerative systems are described.

  6. Local authority leading the way in bioenergy

    International Nuclear Information System (INIS)

    Oertenblad, H.

    2005-01-01

    EnergiGruppen Jylland is a modern supply company owned by the municipality of Herning, a medium-sized municipality situated in the centre of Jutland. EnergiGruppen aims at being a visible actor on the energy market. EnergiGruppen Jylland is founded in the beginning of the last century distributing water and electricity, and in 1950 the group extended the service to distributing heat as well. Within the last 10 years, the utilities have carried out a massive extension of the collective heat supply not only to the city of Herning, but also to the neighbouring villages. The extension is based on renewable energy sources

  7. Energetic retrofitting of industrial heat supply systems. Possibilities of enhancing the efficiency and energy conservation at large combustion engineering plants; Energetische Modernisierung industrieller Waermeversorgungssysteme. Moeglichkeiten der Effizienzsteigerung und der Energieeinsparung an grossen feuerungstechnischen Anlagen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-12-15

    In the contribution under consideration, the Deutsche Energie-Agentur GmbH (Berlin, Federal Republic of Germany) reports on an energetic modernization of industrial heat supply systems. Possibilities of an enhancement of the energetic efficiency and energy conservation at large combustion engineering plants are described. After an introduction to this theme, the author of this contribution provides an overview of the optimization of heat supply systems, and reports on the following aspects: Optimisation of the heat demand; energy efficient heat generation; heat recovery; energy efficient conversion technology and generation technology; associate partners for more energy efficiency in industry and commerce; best practice examples.

  8. Non-composted municipal solid waste byproduct influences soil and plant nutrients five years after soil reclamation

    Science.gov (United States)

    Concerns for the mounting supply of municipal solid waste being generated combined with decreasing landfill space have compelled military installations to evaluate alternative methods for disposal. One approach to reduce landfilling is the use of a new garbage-processing technology that sterilizes a...

  9. USING REGIONAL RENEWABLE ENERGY RESOURSES FOR HEATING SUPPLY SYSTEMS

    Directory of Open Access Journals (Sweden)

    O. M. Pshinko

    2017-02-01

    Full Text Available Purpose. The study analyzed the possibility and conditions for the effective operation of heating systems during the transition of the heat-generating capacity to biofuels energy. The straw of cereal crops, which are prevailing in Dnipro region, is used for this. The main purpose is scientific calculation of opportunities and cost of specific measures for such a transition. As an example it was taken the boiler-room of campus at Dnipropetrovsk National University of Railway Transport named after Academician V. Lazaryan (DNURT that consumes natural gas. Methodology. The work analyses the legislative base of Ukraine, which promotes the using of renewable energy sources as fuel, as well as the incentive mechanisms for the development of this trend. The paper identifies opportunities of Prydniprovsk region to ensure straw supply for the boiler-room. Cost parameters of cargo transportation on the territory of Ukraine in 2016, which depend on the distance and the size of the trucks, are analysed. These indicators, as well as indicators related to its purchase, are considered together with energy potential of using the straw as fuel. Findings. With existing in Ukraine (as of 2016 the grain yielding capacity in the agriculture and cost indicators in the field of transportations, the transition of capacity share to biofuel is sufficiently profitable. The thermal power unit cost can be reduced fourfold. Originality. For the first time it is proposed to use the new integrated approaches to assess the cost of thermal power unit boiler with its transition to the use of renewable energy sources. The authors also proposed a new logistics delivery of these sources to the place of their application. From a technical and cost points of view it was determined the optimal order of capacity transfer for new renewable sources of energy in a given region depending on the structure of areas under crops and their productivity. Originality. The introduction of the

  10. Municipal energy and climate policy in a liberalized energy market

    International Nuclear Information System (INIS)

    Burger, H.

    2001-05-01

    Due to the ongoing process of liberalisation, Dutch municipal energy policy is undergoing significant changes. The probable privatisation of energy companies, the change from what used to be 'their' local energy company to what will become an energy company, results in a need for local administrations to build up energy knowledge, end-use information and financial resources that 'their' energy companies used to share but, because of operating in a competitive market, are now more reluctant to do so. On the other hand offers privatisation and the selling of shares the possibility for some local governments to collect a significant sum of money which can be addressed to energy policy. This process of growing responsibility of local administrations for their own energy policy coincides with the structural change of the nature of the energy supply in the Netherlands. The change towards a more decentralised energy supply results in more energy systems (e.g. PV and wind) coming under the influence of local regulations. Municipal governments will have to act more like actors in a complex policy network, playing different roles at different times in different situations, often stimulating and regulating at the same time. The growing popularity of platforms like energy agencies, bringing together parties like the local government, energy companies and commercial- and housing associations are examples hereof. In this report, another new role for local governments resulting from the liberalisation process is highlighted: the role of energy consumer. It is estimated that the aggregated electricity demand resulting from activities under direct municipal responsibility (e.g. municipal dwellings, traffic lights, public lighting) amounts to a fairly large share of the market. Due to the public interests vested in the local administrations, it is expected that an important part of this demand is demand for green electricity. Also, local governments can use the energy markets to act

  11. The problems and development potential of revenue autonomy in Estonian municipalities. Kohalike omavalitsuste tuluautonoomia probleemid ja arenguvõimalused Eestis

    Directory of Open Access Journals (Sweden)

    Janno Reiljan

    2013-01-01

    Full Text Available In a regionally heterogeneous country like Estonia, it is a difficult task to create a local government revenue structure that guarantees even supply of public services across the entire country and, at the same time, revenue autonomy for the municipalities. In the theoretical part of the current article the suitability of different sources of own revenues are analysed in the context of Estonian municipalities. The empirical part of the article compares the financing principles of Estonian municipalities with other EU countries. Finally, the proportions of different own sources of revenues in the budgets of Estonian local governments are examined and suggestions are made for changing the current system

  12. Balancing the supply mix to meet tomorrow's energy needs

    International Nuclear Information System (INIS)

    Wiggin, M.

    2004-01-01

    This presentation emphasized the need to balance the power supply mix to ensure future energy needs. A balanced supply includes generation supply options that include renewable energy sources, natural gas, oil or coal. The role of combined heat and power (CHP) and district energy in this supply mix is considered to be a potential generation solution. The challenge facing Ontario's Independent Electricity Market Operator (IMO) is to balance supply and demand, phase out coal, promote renewables, diminish demand and determine the new role for natural gas. A graph by the National Energy Board depicting Canada's energy future and scenarios for supply and demand to 2025 indicates that gas yields from the Western Canada Sedimentary Basin are declining. It is expected that with growing demands for natural gas, prices will remain high and there will be a need for new generation capacity. The viable options for energy supply include a re-examination of the district energy advantage through industrial waste heat, biomass and other renewables, and the integration of industrial and community energy systems. Other options include the continued recognition of distributed generation in the form of combined heat and power. 4 figs

  13. Heating plant privatization stagnates

    International Nuclear Information System (INIS)

    Janoska, J.; Benka, M.; Sobinkovic, B.; Haluza, I.

    2005-01-01

    The state has been talking about privatization of 6 municipal heating plants since 2001. The tenders were to start last year. But nothing has happened and the future is uncertain. The city councils would prefer to receive, if not 100%, then at least a majority stake in the heating plants free of charge. But the Cabinet has decided to sell 51% to investors. The privatization agency - the National Property Fund (FNM) is preparing a proposal to increase the stake offered for sale to 67%. According to information provided by the FNM the sale will begin after Cabinet approval. The Fund intends to apply the same model to the sale of all the heating plants. Last year, a major German company Verbundnetz Gas declared its interest in purchasing large municipal heating plants in Slovakia. But it has been waiting for a response ever since. The French company - Dalkia, which has 10-years' experience of doing business in Slovakia, is interested in all the heating plants to be offered for sale. The Austrian company - Stefe is not new to the business either, it is interested mainly in the regions where it has already established itself - Central and Eastern Slovakia. Strategic investors expect financial groups to show interest too. The Penta Group has not hid its ambitions - it has already privatised a company which represents the key to the future development of heat management in Bratislava - Paroplynovy cyklus. Whereas Penta is not new to the heat production business another financial group - Slavia Capital is still surveying the sector. Should it not succeed, it plans several projects that would allow it to take a stake in the sector

  14. Heat pump heating with heat pumps driven by combustion engines or turbines

    Energy Technology Data Exchange (ETDEWEB)

    Hein, K

    1977-01-27

    The heat pump described is driven by a gas Otto cycle engine, or a gas- or light- or heavy-oil fired Diesel engine. The claim refers to the use of waste heat of the engines by feeding into the input circuit of the heat pump. In addition, a drive by an electrical motor-generator or power production can be selected at times of peak load in the electrical supply network.

  15. Appreciation analysis for power supply companies; Wertsteigerungsanalyse fuer Energieversorgungsunternehmen

    Energy Technology Data Exchange (ETDEWEB)

    Muche, T. [Hochschule Zittau/Goerlitz (Germany)

    2007-08-15

    In view of the probable future consolidation in the energy economy with municipal undertakings increasingly becoming subject to takeovers and participations issues of shareholder value are a matter of growing interest for power supply companies. Amongst other advantages, having a high shareholder value guards against unwanted takeovers. However, it is not enough for companies merely to know their shareholder value; they must rather have their entire operative and strategic planning and control instruments geared to it. This forms the background to a pilot project at Goerlitz/Zittau University which was dedicated to an analysis of the shareholder value of municipal undertakings on the basis of year-end financial and capital market data.

  16. Longevity characteristics of flat solar water-heating collectors in hot-water-supply systems. Part 1. Procedure for calculating collector thermal output

    International Nuclear Information System (INIS)

    Avezova, N.R.; Ruziev, O. S.; Suleimanov, Sh. I.; Avezov, R. R.; Vakhidov, A.

    2013-01-01

    A procedure for calculating longevity indices (daily and monthly variations and, hence, annual thermal output) of flat solar water-heating collectors, amount of conditional fuel saved per year by using solar energy, and cost of solar fuel and thermal energy generated in hot-water-supply systems is described. (authors)

  17. Pumped two-phase heat transfer loop

    Science.gov (United States)

    Edelstein, Fred

    1988-01-01

    A pumped loop two-phase heat transfer system, operating at a nearly constant temperature throughout, includes several independently operating grooved capillary heat exchanger plates supplied with working fluid through independent flow modulation valves connected to a liquid supply line, a vapor line for collecting vapor from the heat exchangers, a condenser between the vapor and the liquid lines, and a fluid circulating pump between the condenser and the heat exchangers.

  18. Flexible, pre-insulated pipelines for heat and water supply. Systems with integrated quality and service; Flexible, vorgedaemmte Rohrsysteme fuer die Versorgungstechnik. Gesamtsysteme mit Qualitaet und Service

    Energy Technology Data Exchange (ETDEWEB)

    Hetzel, Michaela [Uponor Central Europe, Hassfurt (Germany). Unternehmenskommunikation

    2010-10-15

    Flexible pipes are suited for heat distribution, cooling water and freshwater transport. Uponor uses a modified, cross-linked polythene for insulation. The material is flexible, ageing-resistant, and will reduce the heat loss. Pipes are supplied to the construction site within two days, cut to measure and with all required parts. (orig.)

  19. Energy and exergy analysis of low temperature district heating network

    International Nuclear Information System (INIS)

    Li, Hongwei; Svendsen, Svend

    2012-01-01

    Low temperature district heating with reduced network supply and return temperature provides better match of the low quality building heating demand and the low quality heating supply from waste heat or renewable energy. In this paper, a hypothetical low temperature district heating network is designed to supply heating for 30 low energy detached residential houses. The network operational supply/return temperature is set as 55 °C/25 °C, which is in line with a pilot project carried out in Denmark. Two types of in-house substations are analyzed to supply the consumer domestic hot water demand. The space heating demand is supplied through floor heating in the bathroom and low temperature radiators in the rest of rooms. The network thermal and hydraulic conditions are simulated under steady state. A district heating network design and simulation code is developed to incorporate the network optimization procedure and the network simultaneous factor. Through the simulation, the overall system energy and exergy efficiencies are calculated and the exergy losses for the major district heating system components are identified. Based on the results, suggestions are given to further reduce the system energy/exergy losses and increase the quality match between the consumer heating demand and the district heating supply. -- Highlights: ► Exergy and energy analysis for low and medium temperature district heating systems. ► Different district heating network dimensioning methods are analyzed. ► Major exergy losses are identified in the district heating network and the in-house substations. ► Advantages to apply low temperature district heating are highlighted through exergy analysis. ► The influence of thermal by-pass on system exergy/energy performance is analyzed.

  20. Power/heat production from biomass in Finland - Two modern Finnish examples

    International Nuclear Information System (INIS)

    Aeijaelae, M.

    1997-01-01

    According to this conference paper, Finland is a leading country in the utilization of biomass fuels for power and heat production. One reason is that peat and wood are the only indigenous fuels available in Finland. Other reasons are the strong forest industry and the widely adopted combined heat and power (CHP) production. CHP production is typical of process industry and municipal district heating. The most common boiler type in modern CHP plants is the fluidized bed type. District heating is the cheapest heating in municipalities with a few thousand inhabitants. Electric heating dominates in sparsely populated regions. CHP becomes attractive for populations of more than ten thousand. Two examples are described: (1) Rauhalahti Power Plant produces 140 MW of district heat, 65 MW of industrial steam and 87 MW of electricity. (2) Kuusamo Power Plant produces 6.1 MW electric energy and 17.6 MW district heat; its unique feature is the utilization of the bed mixing dryer for drying of the fuel prior to combustion, this dryer being the first of its kind in the world. 1 figure

  1. Feasibility analysis of municipal solid waste mass burning in the Region of East Macedonia--Thrace in Greece.

    Science.gov (United States)

    Athanasiou, C J; Tsalkidis, D A; Kalogirou, E; Voudrias, E A

    2015-06-01

    The present work conducts a preliminary techno-economic feasibility study for a single municipal solid waste mass burning to an electricity plant for the total municipal solid waste potential of the Region of Eastern Macedonia - Thrace, in Greece. For a certain applied and highly efficient technology and an installed capacity of 400,000 t of municipal solid waste per year, the available electrical power to grid would be approximately 260 GWh per year (overall plant efficiency 20.5% of the lower heating value). The investment for such a plant was estimated at €200m. Taking into account that 37.9% of the municipal solid waste lower heating value can be attributed to their renewable fractions, and Greek Law 3851/2010, which transposes Directive 2009/28/EC for Renewable Energy Sources, the price of the generated electricity was calculated at €53.19/MWhe. Under these conditions, the economic feasibility of such an investment depends crucially on the imposed gate fees. Thus, in the gate fee range of 50-110 € t(-1), the internal rate of return increases from 5% to above 15%, whereas the corresponding pay-out time periods decrease from 11 to about 4 years. © The Author(s) 2015.

  2. Towards a Future of District Heating Systems with Low-Temperature Operation together with Non-Fossil Fuel Heat Sources

    DEFF Research Database (Denmark)

    Tol, Hakan; Dinçer, Ibrahim; Svendsen, Svend

    2012-01-01

    This study focused on investigation of non-fossil fuel heat sources to be supplied to low-energy district heating systems operating in low temperature such as 55 C and 25 C in terms of, respectively, supply and return. Vast variety of heat sources classed in categories such as fossil fuel...

  3. Improving the performance of district heating systems by utilization of local heat boosters

    DEFF Research Database (Denmark)

    Falcone, A.; Dominkovic, D. F.; Pedersen, A. S.

    was to evaluate the possibilities to lower the forward temperature of the heat supply in order to reduce the heat losses of the system. Booster heat pumps are introduced to increase the water temperature close to the final users. A Matlab model was developed to simulate the state of the case study DH network...... was set to minimize the system heat losses. * Corresponding author 0303-1 1 This goal was achieved by lowering the forward temperature to 40°C and relying on the installed heat pumps to boost the water temperature to the admissible value needed for the domestic hot water preparation. Depending......District Heating (DH) plays an important role into the Danish energy green transition towards the future sustainable energy systems. The new, 4 th generation district heating network, the so called Low Temperature District Heating (LTDH), tends to lower the supply temperature of the heat down to 40...

  4. Simulation of hybrid ground-coupled heat pump with domestic hot water heating systems using HVACSIM+

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Ping; Yang, Hongxing [Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong (China); Spitler, Jeffrey D. [School of Mechanical Engineering, Oklahoma State University (United States); Fang, Zhaohong [Ground Source Heat Pump Research Center, Shandong University of Architecture and Engineering, Jinan (China)

    2008-07-01

    A hybrid ground-coupled heat pump (HGCHP) with domestic hot water (DHW) supply system has been proposed in this paper for space cooling/heating and DHW supply for residential buildings in hot-climate areas. A simulation model for this hybrid system is established within the HVACSIM+ environment. A sample system, applied for a small residential apartment located in Hong Kong, is hourly simulated in a typical meteorological year. The conventional GCHP system and an electric heater for DHW supply are also modeled and simulated on an hourly basis within the HVACSIM+ for comparison purpose. The results obtained from this case study show that the HGCHP system can effectively alleviate the imbalanced loads of the ground heat exchanger (GHE) and can offer almost 95% DHW demand. The energy saving for DHW heating is about 70% compared with an electric heater. This proposed scheme, i.e. the HGCHP with DHW supply, is suitable to residential buildings in hot-climate areas, such as in Hong Kong. (author)

  5. LEAP: local environmental action plan. Municipality of Dolneni

    International Nuclear Information System (INIS)

    2004-01-01

    The Municipality of Dolneni is situated in the northern part of the Pelagonia Valley, at about 600 meters above the sea level. It is surrounded on three sides (north, northeast, east and northwest) by the mountain massifs of Dautica, Babuna and Busova Planina. The assesment of the state of the environment in the Municipality of Dolneni presented in this document is based on several principles, including, before all, human health, as well as impacts from human activities on urban and natural environment, social and economic development, etc. The impacts from environmental pollution on human health in the Municipality of Dolneni are evident. Major problem is the lack of sewerage system to collect wastewater and absence of organized landfill(s) for solid waste disposal. In addition, the improper drinking water supply in most of the settlements contributes to the increased human health risk in the Municipality. The absence of urban planning has lead to developments and uncontrolled use of natural resources that cause degradation of the environment and consequently decrease in quality of living for the population. The above problems affect the quality of living conditions and human health both directly and indirectly. In recent years, incidence of epidemics of communicable hepatitis was recovered (Debreste, Desovo), and there is a concern for a high risk of appearance of intestinal and other infectious diseases. There are no indicators of the soil quality of surface running water resources with regard to pollution. In any case, on the basis of the manner of land use and specific human activities on the territory of the Municipality, as well as on the basis of the above mentioned solid waste and waste water related problems, it may be concluded that these resources are in a rather poor condition. Other aspects of determining the quality of the environment (atmosphere, noise, natural ecosystems and biodiversity in general) are not under serious human pressure at present

  6. Survival and multiplication of Legionella pneumophila in municipal drinking water systems.

    Science.gov (United States)

    States, S J; Conley, L F; Kuchta, J M; Oleck, B M; Lipovich, M J; Wolford, R S; Wadowsky, R M; McNamara, A M; Sykora, J L; Keleti, G

    1987-05-01

    Studies were conducted to investigate the survival and multiplication of Legionella spp. in public drinking water supplies. An attempt was made, over a period of several years, to isolate legionellae from a municipal system. Sampling sites included the river water supply, treatment plant, finished water reservoir system, mains, and distribution taps. Despite the use of several isolation techniques, Legionella spp. could not be detected in any of the samples other than those collected from the river. It was hypothesized that this was due to the maintenance of a chlorine residual throughout the system. To investigate the potential for Legionella growth, additional water samples, collected from throughout the system, were dechlorinated, pasteurized, and inoculated with Legionella pneumophila. Subsequent growth indicated that many of these samples, especially those collected from areas affected by an accumulation of algal materials, exhibited a much greater ability to support Legionella multiplication than did river water prior to treatment. Chemical analyses were also performed on these samples. Correlation of chemical data and experimental growth results indicated that the chemical environment significantly affects the ability of the water to support multiplication, with turbidity, organic carbon, and certain metals being of particular importance. These studies indicate that the potential exists for Legionella growth within municipal systems and support the hypothesis that public water supplies may contaminate the plumbing systems of hospitals and other large buildings. The results also suggest that useful methods to control this contamination include adequate treatment plant filtration, maintenance of a chlorine residual throughout the treatment and distribution network, and effective covering of open reservoirs.

  7. Experimental investigation and feasibility analysis on a capillary radiant heating system based on solar and air source heat pump dual heat source

    International Nuclear Information System (INIS)

    Zhao, M.; Gu, Z.L.; Kang, W.B.; Liu, X.; Zhang, L.Y.; Jin, L.W.; Zhang, Q.L.

    2017-01-01

    Graphical abstract: (a) Vertical temperature gradient in Case 3, (b) PMV and PPD of the test room in Case 3, (c) operating time of SPCTS and ASHP systems in Case 3 and (d) the proportion of SPCTS operating time. - Highlights: • A capillary heating system based on solar and air source heat pump was developed. • Influence of supply water temperature on solar energy saving rate was investigated. • Heating performance and thermal comfort of capillary heating system were analyzed. • Low temperature heating with capillary is suitable for solar heating system. - Abstract: Due to sustainable development, solar energy has drawn much attention and been widely applied in buildings. However, the application of solar energy is limited because of its instability, intermittency and low energy density in winter. In order to use low density and instable solar energy source for heating and improve the utilization efficiency of solar energy, a solar phase change thermal storage (SPCTS) heating system using a radiant-capillary-terminal (RCT) to effectively match the low temperature hot water, a phase change thermal storage (PCTS) to store and continuously utilize the solar energy, and an air source heat pump (ASHP) as an alternate energy, was proposed and set up in this research. Series of experiments were conducted to obtain the relation between the solar radiation utilization rate and the heating supply temperatures, and to evaluate the performance of the RCT module and the indoor thermal environment of the system for its practical application in a residential building in the north-western City of Xi’an, China. The results show that energy saving of the solar heating system can be significantly improved by reducing the supplied water temperature, and the supplied water temperature of the RCT would be no more than 35 °C. The capillary radiation heating can adopt a lower water temperature and create a good thermal comfort environment as well. These results may lead to the

  8. Assessment of heavy metals in the industrial effluents, tube-wells and municipal supplied water of Dehradun, India.

    Science.gov (United States)

    Kulshrestha, Shail; Awasthi, Alok; Dabral, S K

    2013-07-01

    The bio-geochemical cycles of metals involve the lands, rivers, oceans and the atmosphere. Although a large number of metals are introduced to the water bodies during their mining and extraction processes and geochemical weathering of rocks, but the role of domestic and industrial wastes is predominant and of much concern. Increased industrial activities has increased the incidence of percolation of toxic metal ions to the soil and water bodies and presently their presence in ecosystem, have reached to an alarming level that environmentalists are finding it difficult to enforce control measures. Human activities and large number of small and big industrial units are increasingly discharging deleterious metals present in the effluents and wastes, to the environment and aquatic systems and have contaminated heavily even the ground water. The toxic metals have a great tendency of bioaccumulation through which they enter the food chain system and ultimately affect adversely the life on this planet Earth in various ways. Further, due to contamination of irrigation system by the harmful Chemicals and toxic metals, the farm products, vegetables, fruits, potable water and even milk is not spared. This paper describes the assessment of the heavy metal concentration in various industrial effluents of the surrounding area. Various physico-chemical characteristics of the effluents collected from various sites are also reported. To assess the status of ground water quality, water samples from four tube wells of different localities of the area and four drinking water samples supplied by Municipal Distribution System were also analyzed.

  9. Sami-speaking municipalities and a control group's access to somatic specialist health care (SHC: a retrospective study on general practitioners’ referrals

    Directory of Open Access Journals (Sweden)

    Jan Norum

    2012-03-01

    Full Text Available Objectives: The Sami people constitute the indigenous people in northern Norway. The objective of this study was to clarify whether they have a similar supply of somatic specialist health care (SHC as others. Methods: The referrals from general practitioners (GPs in the primary health care (PHC in the administration area of the Sami language law (8 municipalities were matched with a control group of 11 municipalities. Population data was accessed from Statistics Norway and the time period 2007–2010 was analysed. The main outcome was the number of referrals per 1,000 inhabitants according to age group, gender and place of living. Results: 504,292 referrals in northern Norway were indentified and the Sami and control group constituted 23,093 and 22,541 referrals, respectively. The major findings were a similar referral ratio (RR (1.14 and 1.17 (p = 0.624 and women more commonly referred (female/male ratio 1.45 and 1.41 in both groups. GPs in both groups were loyal to their local hospital trust. Conclusion: Inhabitants in Sami-speaking municipalities in northern Norway have a similar supply of SHC services as controls. Inter-municipal variation was significant in both groups.

  10. Heat Roadmap Europe: Identifying strategic heat synergy regions

    International Nuclear Information System (INIS)

    Persson, U.; Möller, B.; Werner, S.

    2014-01-01

    This study presents a methodology to assess annual excess heat volumes from fuel combustion activities in energy and industry sector facilities based on carbon dioxide emission data. The aim is to determine regional balances of excess heat relative heat demands for all third level administrative regions in the European Union (EU) and to identify strategic regions suitable for large-scale implementation of district heating. The approach is motivated since the efficiency of current supply structures to meet building heat demands, mainly characterised by direct use of primary energy sources, is low and improvable. District heating is conceived as an urban supply side energy efficiency measure employable to enhance energy system efficiency by increased excess heat recoveries; hereby reducing primary energy demands by fuel substitution. However, the importance of heat has long been underestimated in EU decarbonisation strategies and local heat synergies have often been overlooked in energy models used for such scenarios. Study results indicate that 46% of all excess heat in EU27, corresponding to 31% of total building heat demands, is located within identified strategic regions. Still, a realisation of these rich opportunities will require higher recognition of the heat sector in future EU energy policy. - Highlights: • EU27 energy and industry sector heat recycling resources are mapped and quantified. • Target regions for large-scale implementation of district heating are identified. • 46% of total EU27 excess heat volume is seized in 63 strategic heat synergy regions. • Large urban zones have lead roles to play in transition to sustainability in Europe. • Higher recognition of heat sector is needed in future EU energy policy for realisation

  11. Industrial waste heat for district heating

    International Nuclear Information System (INIS)

    Heitner, K.L.; Brooks, P.P.

    1982-01-01

    Presents 2 bounding evaluations of industrial waste heat availability. Surveys waste heat from 29 major industry groups at the 2-digit level in Standard Industrial Codes (SIC). Explains that waste heat availability in each industry was related to regional product sales, in order to estimate regional waste heat availability. Evaluates 4 selected industries at the 4-digit SIC level. Finds that industrial waste heat represents a significant energy resource in several urban areas, including Chicago and Los Angeles, where it could supply all of these areas residential heating and cooling load. Points out that there is a strong need to evaluate the available waste heat for more industries at the 4-digit level. Urges further studies to identify other useful industrial waste heat sources as well as potential waste heat users

  12. Properties of municipal solid waste incineration ashes with respect to their separation temperature

    Czech Academy of Sciences Publication Activity Database

    Keppert, M.; Pavlík, Z.; Tydlitát, V.; Volfová, P.; Švarcová, Silvie; Šyc, Michal; Černý, R.

    2012-01-01

    Roč. 30, č. 10 (2012), s. 1041-1048 ISSN 0734-242X Institutional support: RVO:61388980 ; RVO:67985858 Keywords : bottom ash * fly ash * municipal solid waste incinerator * pozzolanic activity * hydration heat * separation temperature * building industry Subject RIV: CA - Inorganic Chemistry Impact factor: 1.047, year: 2012

  13. Solid state modulator for klystron power supply XFEL TDS INJ

    Science.gov (United States)

    Zavadtsev, A. A.; Zavadtsev, D. A.; Zybin, D. A.; Churanov, D. V.; Shemarykin, P. V.

    2016-09-01

    The transverse deflecting system XFEL TDS INJ for European X-ray Free Electron Laser includes power supply for the CPI VKS-8262HS klystron. It has been designed for pulse high-voltage, cathode heating, solenoid and klystron ion pump. The klystron power supply includes solid state modulator, pulse transformer, controlled power supply for cathode heating and commercial power supplies for solenoid and ion pump. Main parameters of the modulator are 110 kV of peak voltage, 72 A peak current, and pulse length up to 6 μs. The klystron power supply has been developed, designed, manufactured, tuned, tested and installed in the XFEL building. All designed parameters are satisfied.

  14. Line voltage distortions due to operation of the power supply devices required for plasma heating and magnetic field generation in the W7X thermonuclear fusion experiment

    International Nuclear Information System (INIS)

    Werner, F.

    1997-03-01

    The operation of the W7-X plasma heating devices requires high voltage DC power supplies with a total electrical power of 40 MVA. For this purpose twelve-pulse AC/DC converters are projected. These converters enforce a non sinusoidal line current, whose harmonics are causing corresponding line voltage distortions. To evaluate the extent of these distortions, the reaction of the harmonic currents on the AC line, is investigated by numerical network analysis. This is done for both, the 20 kV-junction point of the converters and the 110 kV-line terminal of the electricity supply company. Furthermore the design of LC series-resonant circuits, projected for power factor correction and damping of the harmonic content of the line voltage, has been verified. The additional operation of the 1.5 MVA magnet power supplies also contributes, even though to a much smaller extent, to the line voltage distortion. The influence of these twelve-pulse AC/DC converters was investigated too. The numerical calculations have been done with the aid of the network simulation program 'Pspice'. In an equivalent circuit the transmission line network and the transformers are represented by their inductances respectively equivalent inductances. The rectifier units are simulated by a number of current sources, producing the current harmonics in amplitude, frequency and phase. The harmonics amplitudes of the plasma heating power supplies are frequency and phase. The harmonics amplitudes of the plasma heating power supplies are measured values given by the manufacturer. For the magnet power supplies, the harmonics are derived from the theoretical step like I(t) current shape by Fourier series decomposition. Due to the action of the LC circuits the achieved characteristic voltage quality values are far below the permissible values corresponding to the recommendations of VDE 0160. (orig.) [de

  15. Municipal consultation key to understanding haul road maintenance agreements for Saskatchewan rural municipalities

    International Nuclear Information System (INIS)

    Leibel, R.E.A.

    1998-01-01

    Current municipal perspectives regarding the oil and gas industry in Saskatchewan were described. Municipal jurisdiction and authority regarding road development and heavy haul road maintenance agreements were defined. Based on actual work experience, collaborative working relationships between the oil and gas industry and the municipal sector is well worth some industry time and effort since it will result in cost savings for the industry. In general, rural municipalities receive very limited tax benefits to recapture the costs of road reconstruction and maintenance caused by heavy industry traffic. Road servicing costs can be recaptured only if companies respect the weight limits, hauling regulations and road bans. On the whole, municipalities in Saskatchewan are favourably disposed towards the oil and gas industry, and have done well in the past to accommodate industry's needs. It is not unreasonable therefore to expect that industry show sensitivity to the impact of its activities on the local municipality, and does its level best to be on good terms with the municipalities through early two-way communication. Text of some relevant acts of the Legislature respecting the powers and authorities of rural municipalities are appended

  16. Heat extraction from turbines of Czechoslovak nuclear power plants for district heating

    International Nuclear Information System (INIS)

    Drahy, J.

    1985-01-01

    Two design are described of SKODA extraction turbines for Czechoslovak nuclear power plants with WWER-440 and WWER-1000 reactors. 220 MW steam turbines were originally designed as pure condensation turbines with uncontrolled steam extraction. Optimal ways are now being sought for their use for heating hot water for district heating. For district heating of the town of Trnava, the nuclear power plant at Jaslovske Bohunice will provide a two-step heating of water from 70 to 120 degC with a heat supply of 60 MW th from one turbine unit. The ratio of obtained heat power to lost electric power is 5.08. Investigations showed the possibility of extracting 85 MW th of heat from uncontrolled steam extraction, this at three-step water heating from 60 to 145 degC, the ratio of gained and lost power being 7.14. Information is presented on the SKODA 220 MW turbine with steam extraction for heat supply purposes and on the 1000 MW turbine with 893 MW th heat extraction. The specifications of both types are given. (Pu)

  17. Performance of Space Heating in a Modern Energy System

    DEFF Research Database (Denmark)

    Elmegaard, Brian

    2011-01-01

    In the paper we study the performance of a number of heat supply technologies. The background of the study is the changes in the Danish energy systems over the last three decades which have caused integration of large shares of combined heat and power (CHP), renewable fuels and wind power....... These changes mean that there is a significant integration of electricity and heat supply in the system and that several technologies may be beneficial. In particular, heat pumps are under consideration and are often considered to be renewable energy. We study how to distribute fuel and emissions to the heat...... supply. We find that heat supply is low-efficient seen from an exergy viewpoint, between 1% and 26% utilization. As exergy is a quantification of primary energy, we conclude that far better utilization of primary energy is possible. We also find that combined heat and power and domestic heat pumps...

  18. Co-operatives as heating entrepreneurs

    International Nuclear Information System (INIS)

    Honkasalo, M.

    2000-01-01

    The objective of heating entrepreneurship functioning in the form of a co operative is to make the use of the wood chips competitive primarily through district heating of municipal centres. When compared with the conventional heating mode the reliability of chip delivery and the remuneration paid to the co-operative for attending to the running of the heating centres are considered to be the competitive advantages. The system has proven to be a working one; one indication of this is its growing application in the country. In the spring of the year 2000 there were 26 chip-based energy co-operative active in Finland. The first time that the use of bioenergy underwent a powerful rise was in the 1970s as a consequence of the oilcrises. Subsequently the enthusiasm shown to this energy form subsided. Then in the early 1990s, biofuels once again became a subject of interest mainly due to environmental issues, the restructuring of rural areas and silvicultural reasons. With the past decades' experiences forming the basis, the development needs associated with the use of bioenergy were in fresh memory and they were addressed on a wide font. Boiler technology related to solid fuels evolved rapidly and the least successful manufacturers had been eliminated by the recession. In the case of co-operative heating entrepreneurship, the commonest form neither the district heating centre nor the system of heat-transfer pipes belong to co-operative society. The co-operative is responsible only for the delivery of the fuel and for looking after the heating plant. Remuneration is generally based on the amount of energy leaving the district heating plant. Thus the heat dissipated at the heating plant is the co-operative's problem and the heat dissipated during transfer are the energy buyer's problem. The investor in the equipments usually the local municipality or an energy utility. In some cases the co-operative owns the equipments well, in which case it is correct to speak of

  19. Decreasing of energy consumption for space heating in existing residential buildings; Combined geothermal and gas district heating systems

    International Nuclear Information System (INIS)

    Rosca, Marcel

    2000-01-01

    The City of Oradea, Romania, has a population of about 230 000 inhabitants. Almost 70% of the total heat demand, including industrial, is supplied by a classical East European type district heating system. The heat is supplied by two low grade coal fired co-generation power plants. The oldest distribution networks and substitutions, as well as one power plant, are 35 years old and require renovation or even reconstruction. The geothermal reservoir located under the city supplies at present 2,2% of the total heat demand. By generalizing the reinjection, the production can be increased to supply about 8% of the total heat demand, without any significant reservoir pressure or temperature decline over 25 years. Another potential energy source is natural gas, a main transport pipeline running close to the city. Two possible scenarios are envisaged to replace the low grade coal by natural gas and geothermal energy as heat sources for Oradea. In one scenario, the geothermal energy supplies the heat for tap water heating and the base load for space heating in a limited number of substations, with peak load being produced by natural gas fired boilers. In the other scenario, the geothermal energy is only used for tap water heating. In both scenarios, all substations are converted into heat plants, natural gas being the main energy source. The technical, economic, and environmental assessment of the two proposed scenarios are compared with each other, as well as with the existing district heating system. Two other possible options, namely to renovate and convert the existing co-generation power plants to natural gas fired boilers or to gas turbines, are only briefly discussed, being considered unrealistic, at least for the short and medium term future. (Author)

  20. Heat exchanger

    Science.gov (United States)

    Wolowodiuk, Walter

    1976-01-06

    A heat exchanger of the straight tube type in which different rates of thermal expansion between the straight tubes and the supply pipes furnishing fluid to those tubes do not result in tube failures. The supply pipes each contain a section which is of helical configuration.

  1. High voltage power supplies for ITER RF heating and current drive systems

    International Nuclear Information System (INIS)

    Gassmann, T.; Arambhadiya, B.; Beaumont, B.; Baruah, U.K.; Bonicelli, T.; Darbos, C.; Purohit, D.; Decamps, H.; Albajar, F.; Gandini, F.; Henderson, M.; Kazarian, F.; Lamalle, P.U.; Omori, T.; Parmar, D.; Patel, A.; Rathi, D.; Singh, N.P.

    2011-01-01

    The RF heating and current drive (H and CD) systems to be installed for the ITER fusion machine are the electron cyclotron (EC), ion cyclotron (IC) and, although not in the first phase of the project, lower hybrid (LH). These systems require high voltage, high current power supplies (HVPS) in CW operation. These HVPS should deliver around 50 MW electrical power to each of the RF H and CD systems with stringent requirements in terms of accuracy, voltage ripple, response time, turn off time and fault energy. The PSM (Pulse Step Modulation) technology has demonstrated over the past 20 years its ability to fulfill these requirements in many industrial facilities and other fusion reactors and has therefore been chosen as reference design for the IC and EC HVPS systems. This paper describes the technical specifications, including interfaces, the resulting constraints on the design, the conceptual design proposed for ITER EC and IC HVPS systems and the current status.

  2. Load Management in District Heating Operation

    DEFF Research Database (Denmark)

    Li, Hongwei; Wang, Stephen Jia

    2015-01-01

    Smooth operation of district heating system will avoid installation of expensive peak heat boilers, improve plant partial load performance, increase the system redundancy for further network expansion and improve its resilience to ensure security of supply during severe heating seasons. The peak...... heating load can be reduced through building demand side management. The building thermal mass can be used to shift the heating supply under the circumstance without jeopardizing the consumer thermal comfort. In this paper, the multi-agent framework is applied to a simplified building dynamic model...

  3. Technical and economic working domains of industrial heat pumps: Part 2 - ammonia-water hybrid absorption-compression heat pumps

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2015-01-01

    The ammonia-water hybrid absorption-compression heat pump (HACHP) has been proposed as a relevant technology for industrial heat supply, especially for high sink temperatures and high temperature glides in the sink and source. This is due to the reduced vapour pressure and the non-isothermal phase...... change of the zeotropic mixture, ammonia-water. To evaluate to which extent these advantages can be translated into feasible heat pump solutions, the working domain of the HACHP is investigated based on technical and economic constraints. The HACHP working domain is compared to that of the best available...... vapour compression heat pump with natural working fluids. This shows that the HACHP increases the temperature lifts and heat supply temperatures that are feasible to produce with a heat pump. The HACHP is shown to be capable of delivering heat supply temperatures as high as 150 °C and temperature lifts...

  4. Technical and Economic Working Domains of Industrial Heat Pumps: Part 2 - Ammonia-Water Hybrid Absorption-Compression Heat Pumps

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2014-01-01

    The ammonia-water hybrid absorption-compression heat pump (HACHP) is a relevant technology for industrial heat supply, especially for high sink temperatures and high temperature glides in the sink and source. This is due to the reduced vapour pressure and the non-isothermal phase change...... of the zeotropic mixture, ammonia-water. To evaluate to which extent these advantages can be translated into feasible heat pump solutions, the working domain of the HACHP is investigated based on technical and economic constraints. The HACHP working domain is compared to that of the best possible vapour...... compression heat pump with natural working fluids. This shows that the HACHP increases the temperature lifts and heat supply temperatures that are feasible to produce with a heat pump. The HACHP is shown to be capable of delivering heat supply temperatures as high as 140 XC and temperature lifts up to 60 K...

  5. Heat Energy Markets: Trends of Spatial Organization

    Directory of Open Access Journals (Sweden)

    Olga Valeryevna Dyomina

    2016-12-01

    Full Text Available The author reviews competing forms of heat supply. It is shown that in Finland, Denmark, China and Russia the dominant form of heat supply is district heating system; in the United States and Canada the dominant form of heat supply is individual one. Using the countries’ data the author allocates 4 models of heat energy markets. The analysis is based on combinations of the following characteristics: the type of market, the orientation of market, the stage of market development, forms of state support of district heating systems and the approach to pricing. The results identified the failure of the current model of heat energy market in Russia (noncompetitive, manufacturer-oriented and evolved market with massive state support of its district heating system. The ‘target’ model of heat energy market in Russia is a model of noncompetitive, customer-oriented and evolved market with no state support of its district heating system. However, the ‘target’ model takes into account spatial heterogeneity of local heat energy markets in Russia only technically

  6. Arsenic in public water supplies and cardiovascular mortality in Spain

    International Nuclear Information System (INIS)

    Medrano, Ma Jose; Boix, Raquel; Pastor-Barriuso, Roberto; Palau, Margarita; Damian, Javier; Ramis, Rebeca; Barrio, Jose Luis del; Navas-Acien, Ana

    2010-01-01

    Background: High-chronic arsenic exposure in drinking water is associated with increased cardiovascular disease risk. At low-chronic levels, as those present in Spain, evidence is scarce. In this ecological study, we evaluated the association of municipal drinking water arsenic concentrations during the period 1998-2002 with cardiovascular mortality in the population of Spain. Methods: Arsenic concentrations in drinking water were available for 1721 municipalities, covering 24.8 million people. Standardized mortality ratios (SMRs) for cardiovascular (361,750 deaths), coronary (113,000 deaths), and cerebrovascular (103,590 deaths) disease were analyzed for the period 1999-2003. Two-level hierarchical Poisson models were used to evaluate the association of municipal drinking water arsenic concentrations with mortality adjusting for social determinants, cardiovascular risk factors, diet, and water characteristics at municipal or provincial level in 651 municipalities (200,376 cardiovascular deaths) with complete covariate information. Results: Mean municipal drinking water arsenic concentrations ranged from 10 μg/L. Compared to municipalities with arsenic concentrations 10 μg/L, respectively (P-value for trend 0.032). The corresponding figures were 5.2% (0.8% to 9.8%) and 1.5% (-4.5% to 7.9%) for coronary heart disease mortality, and 0.3% (-4.1% to 4.9%) and 1.7% (-4.9% to 8.8%) for cerebrovascular disease mortality. Conclusions: In this ecological study, elevated low-to-moderate arsenic concentrations in drinking water were associated with increased cardiovascular mortality at the municipal level. Prospective cohort studies with individual measures of arsenic exposure, standardized cardiovascular outcomes, and adequate adjustment for confounders are needed to confirm these ecological findings. Our study, however, reinforces the need to implement arsenic remediation treatments in water supply systems above the World Health Organization safety standard of 10 μg/L.

  7. Co-Combustion of Municipal Sewage Sludge and Hard Coal on Fluidized Bed Boiler WF-6

    Directory of Open Access Journals (Sweden)

    Rajczyk Rafał

    2014-12-01

    Full Text Available According to data of the Central Statistical Office, the amount of sludge produced in municipal wastewater treatment plants in 2010 amounted to 526000 Mg d.m. The forecast of municipal sewage sludge amount in 2015 according to KPGO2014 will reach 642400 Mg d.m. and is expected to increase in subsequent years. Significant amounts of sludge will create problems due to its utilization. In order to solve this problem the use of thermal methods for sludge utilization is expected. According to the National Waste Management Plan nearly 30% of sewage sludge mass should be thermally utilized by 2022. The article presents the results of co-combustion of coal and municipal sewage sludge in a bubbling fluidized bed boiler made by SEFAKO and located in the Municipal Heating Company in Morag. Four tests of hard coal and sewage sludge co-combustion have been conducted. Boiler performance, emissions and ash quality were investigated.

  8. Estimation of low-potential heat recuperation efficiency of smoke fumes in a condensation heat utilizer under various operation conditions of a boiler and a heating system

    Science.gov (United States)

    Ionkin, I. L.; Ragutkin, A. V.; Luning, B.; Zaichenko, M. N.

    2016-06-01

    For enhancement of the natural gas utilization efficiency in boilers, condensation heat utilizers of low-potential heat, which are constructed based on a contact heat exchanger, can be applied. A schematic of the contact heat exchanger with a humidifier for preheating and humidifying of air supplied in the boiler for combustion is given. Additional low-potential heat in this scheme is utilized for heating of the return delivery water supplied from a heating system. Preheating and humidifying of air supplied for combustion make it possible to use the condensation utilizer for heating of a heat-transfer agent to temperature exceeding the dewpoint temperature of water vapors contained in combustion products. The decision to mount the condensation heat utilizer on the boiler was taken based on the preliminary estimation of the additionally obtained heat. The operation efficiency of the condensation heat utilizer is determined by its structure and operation conditions of the boiler and the heating system. The software was developed for the thermal design of the condensation heat utilizer equipped by the humidifier. Computation investigations of its operation are carried out as a function of various operation parameters of the boiler and the heating system (temperature of the return delivery water and smoke fumes, air excess, air temperature at the inlet and outlet of the condensation heat utilizer, heating and humidifying of air in the humidifier, and portion of the circulating water). The heat recuperation efficiency is estimated for various operation conditions of the boiler and the condensation heat utilizer. Recommendations on the most effective application of the condensation heat utilizer are developed.

  9. Balancing the organic load and light supply in symbiotic microalgal–bacterial biofilm reactors treating synthetic municipal wastewater

    NARCIS (Netherlands)

    Boelee, N.C.; Temmink, B.G.; Janssen, M.; Buisman, C.J.N.; Wijffels, R.H.

    2014-01-01

    Symbiotic microalgal–bacterial biofilms can be very attractive for municipal wastewater treatment. Microalgae remove nitrogen and phosphorus and simultaneously produce the oxygen that is required for the aerobic, heterotrophic degradation of organic pollutants. For the application of these biofilms

  10. Heat exchanger

    International Nuclear Information System (INIS)

    Wolowodiuk, W.

    1976-01-01

    A heat exchanger of the straight tube type is described in which different rates of thermal expansion between the straight tubes and the supply pipes furnishing fluid to those tubes do not result in tube failures. The supply pipes each contain a section which is of helical configuration

  11. Simulation of gas supply and consumption during heating season; Simulacija opskrbe potrosaca plinom tijekom ogrjevne sezone

    Energy Technology Data Exchange (ETDEWEB)

    Oklopcic, Z [INA-Naftaplin, Zagreb (Croatia)

    1997-12-31

    In this paper stochastic simulation model of gas supply and consumption during heating season is described. The simulation of gas supply is based on constant import and domestic production and varying production of underground storage which depends on current needs and quantity of gas in the storage. The basis for consumption simulation is the stochastic relationship between gas consumption and mean daily air temperature and type of the day, expressed in the form of linear regression model. Mean daily air temperatures, as one of basic causes of daily gas consumption variations, are simulated, on the basis of statistical characteristics and own air temperature measurements, as a first order autoregression model. By using the developed simulation model the statistical characteristics (expectation, standard deviation) of daily gas consumption and the difference between maximum possible daily supply and consumption (delivery safety margin) are derived for all days in the season. The definition of gas delivery safety is given and critical delivery probabilities for all days in the season and different safety margins are determined. Also, statistical characteristics of critical delivery duration depending on gas reserves status for underground storage is predicted. Predicted gas storage delivery rate is compared against predicted requirements, and on the basis of this comparison possible bottlenecks in gas delivery to consumers and course of future actions are indicated. (author). 3 tabs., 10 figs., 6 refs.

  12. Air Emission Reduction Benefits of Biogas Electricity Generation at Municipal Wastewater Treatment Plants.

    Science.gov (United States)

    Gingerich, Daniel B; Mauter, Meagan S

    2018-02-06

    Conventional processes for municipal wastewater treatment facilities are energy and materially intensive. This work quantifies the air emission implications of energy consumption, chemical use, and direct pollutant release at municipal wastewater treatment facilities across the U.S. and assesses the potential to avoid these damages by generating electricity and heat from the combustion of biogas produced during anaerobic sludge digestion. We find that embedded and on-site air emissions from municipal wastewater treatment imposed human health, environmental, and climate (HEC) damages on the order of $1.63 billion USD in 2012, with 85% of these damages attributed to the estimated consumption of 19 500 GWh of electricity by treatment processes annually, or 0.53% of the US electricity demand. An additional 11.8 million tons of biogenic CO 2 are directly emitted by wastewater treatment and sludge digestion processes currently installed at plants. Retrofitting existing wastewater treatment facilities with anaerobic sludge digestion for biogas production and biogas-fueled heat and electricity generation has the potential to reduce HEC damages by up to 24.9% relative to baseline emissions. Retrofitting only large plants (>5 MGD), where biogas generation is more likely to be economically viable, would generate HEC benefits of $254 annually. These findings reinforce the importance of accounting for use-phase embedded air emissions and spatially resolved marginal damage estimates when designing sustainable infrastructure systems.

  13. Municipal solid waste disposal in Portugal

    International Nuclear Information System (INIS)

    Magrinho, Alexandre; Didelet, Filipe; Semiao, Viriato

    2006-01-01

    In recent years municipal solid waste (MSW) disposal has been one of the most important environmental problems for all of the Portuguese regions. The basic principles of MSW management in Portugal are: (1) prevention or reduction, (2) reuse, (3) recovery (e.g., recycling, incineration with heat recovery), and (4) polluter-pay principle. A brief history of legislative trends in waste management is provided herein as background for current waste management and recycling activities. The paper also presents and discusses the municipal solid waste management in Portugal and is based primarily on a national inquiry carried out in 2003 and directed to the MSW management entities. Additionally, the MSW responsibility and management structure in Portugal is presented, together with the present situation of production, collection, recycling, treatment and elimination of MSW. Results showed that 96% of MSW was collected mixed (4% was separately collected) and that 68% was disposed of in landfill, 21% was incinerated at waste-to-energy plants, 8% was treated at organic waste recovery plants and 3% was delivered to sorting. The average generation rate of MSW was 1.32 kg/capita/day

  14. Effect of the Cedar River on the quality of the ground-water supply for Cedar Rapids, Iowa

    Science.gov (United States)

    Schulmeyer, P.M.

    1995-01-01

    The Surface Water Treatment Rule under the 1986 Amendment to the Safe Drinking Water Act requires that public-water supplies be evaluated for susceptibility to surface-water effects. The alluvial aquifer adjacent to the Cedar River is evaluated for biogenic material and monitored for selected water-quality properties and constituents to determine the effect of surface water on the water supply for the City of Cedar Rapids, Iowa. Results from monitoring of selected water-quality properties and constituents showed an inverse relation to river stage or discharge. Water-quality properties and constituents of the alluvial aquifer changed as water flowed from the river to the municipal well as a result of drawdown. The values of specific conductance, pH, temperature, and dissolved oxygen at observation well CRM-4 and municipal well Seminole 10 generally follow the trends of values for the Cedar River. Values at observation well CRM-3 and the municipal water-treatment plant showed very little correlation with values from the river. The traveltime of water through the aquifer could be an indication of the susceptibility of the alluvial aquifer to surface-water effects. Estimated traveltimes from the Cedar River to municipal well Seminole 10 ranged from 7 to 17 days.

  15. Transforming the energy system: Why municipalities strive for energy self-sufficiency

    International Nuclear Information System (INIS)

    Engelken, Maximilian; Römer, Benedikt; Drescher, Marcus; Welpe, Isabell

    2016-01-01

    Despite evidence that a rising number of municipalities in Germany are striving for energy self-sufficiency, there is little understanding of the driving factors behind this development. We investigate economic, ecological, social and energy system related factors that drive municipalities to strive for energy self-sufficiency with a focus on electricity supply. The empirical data for this study is based on insights generated through expert interviews (N =19) with mayors, energy experts and scientists as well as a quantitative study among mayors and energy officers (N =109) of German municipalities. Results show that environmental awareness, tax revenues and greater independence from private utilities are positively related to the mayors’ attitude towards the realization of energy self-sufficiency. Furthermore, citizens, the political environment, the mayor's political power, and his/her financial resources are relevant factors for a municipality striving for energy self-sufficiency. Policymakers need to decide whether or not to support mayors in this development. For suitable policy interventions, the results suggest the importance of an integrated approach that considers a combination of identified factors. Finally, we propose a morphological box to structure different aspects of energy self-sufficiency and categorize the present study. - Highlights: • Municipalities striving for energy self-sufficiency can play a key role in the transition of the energy system. • Tax revenues and environmental awareness main drivers behind mayors’ attitude towards energy self-sufficiency. • Citizens and the political environment main influencers of mayors striving for energy self-sufficiency. • 19 expert interviews analyzed for the framework of the study based on the theory of planned behavior (TPB). • 109 mayors and energy officers participated in the quantitative main survey.

  16. Geothermal Power Supply Systems around the World and in Russia: State of the Art and Future Prospects

    Science.gov (United States)

    Butuzov, V. A.; Amerkhanov, R. A.; Grigorash, O. V.

    2018-05-01

    Solar and geothermal energy systems are shown to have received the widest use among all kinds of renewable sources of energy for heat supply purposes around the world. The power capacities and amounts of thermal energy generated by solar and geothermal heat supply systems around the world are presented by way of comparison. The thermal power capacity of solar heat supply systems installed around the world as of 2015 totaled 268.1 GW, and the thermal energy generated by them amounted to 225 TW h/year. The thermal power capacity of geothermal heat supply systems installed around the world totaled 70.3 GW, and the thermal energy generated by them amounted to 163 TW h/year. Information on the geothermal heat supply systems in the leading countries around the world based on the data reported at the World Geothermal Congress held in 2015 is presented. It is shown that China, with the installed thermal power capacities of its geothermal heat supply stations totaling 17.87 GW and the amount of thermal energy generated per annum equal to 48.435 TW h/year, is the world's leader in this respect. The structures of geothermal heat supply systems by the kinds of heat consumption used around the world are presented. The systems equipped with geothermal heat pumps accounted for 70.95% in the total installed capacity and for 55.3% in the total amount of generated heat. For systems that do not use heat pumps, those serving for pools account for the largest share amounting to 44.74% in installed capacity and to 45.43% in generated heat. A total of 2218 geothermal wells with the total length equal to 9534 km (with 38.7% of them for heat supply purposes) were drilled in 42 countries in the period from 2010 to 2014. In Russia, geothermal heat supply systems are in operation mainly in Dagestan, in Krasnodar krai, and in Kamchatka. The majority of these systems have been made without breaking the stream after the well outlet. A cyclic control arrangement is also used. The combined

  17. A transition perspective on alternatives to coal in Chinese district heating

    Directory of Open Access Journals (Sweden)

    Jingjing Zhang

    2015-06-01

    Full Text Available China accounts for half of the world’s annual coal consumption. Coal is the primary energy source for heating in urban areas, particularly in northern China. This causes significant challenges for urban air quality problems in China and greenhouse gases emissions. Urban district heating (DH systems penetration is very high in northern China. It supplies space heating to more than 80% of urban buildings in the area. Unlike the electricity and transportation sectors, the heating sector has received little attention from policy makers and researchers in China, DH systems are an enabling infrastructure which facilitates energy efficiency improvements and the use of renewable energy sources. This study explores the dynamics and possibility to expand alternative energy sources (natural gas, biomass, direct geothermal heat, ground-source heat pump, municipal waste heat, industrial waste heat for DH in China. We apply an analytical framework largely based on the multi-level perspective in socio-technical transitions theory, in which transitions are interpreted as the result of the functioning of niche, regime and landscape elements, and interactions between them. The study provides an integrated picture of the socio-technical structure and functioning of DH in China. The results show that an energy transition in Chinese DH systems has barely started. The system is characterised by stability of the coal-based DH regime, while a number of alternative niches are struggling to emerge. Among these, natural gas is the most successful example. However, at local level different niches present opportunities in terms of physical availability, economic viability and technical capacity to address changes in landscape pressures. A sustainable heat roadmap based on integrated energy planning and policy attention at the national level could be developed as one mechanism for instigating a much needed energy transition in DH in China.

  18. Project financing consequences on cogeneration: industrial plant and municipal utility co-operation in Sweden

    International Nuclear Information System (INIS)

    Sundberg, Gunnel; Sjoedin, J.Joergen

    2003-01-01

    The liberalisation of the European electricity market influences investment decisions in combined heat and power plants. Energy companies modify their business strategies and their criteria for investments in power generation capacity. In this paper, the gains from a co-operation between a paper mill and municipal utility are studied. We find that a widened system boundary, including both the industrial plant and the district heating company, increases cost-effectiveness by 7-11%, compared to a situation with two separately optimised systems. Furthermore, optimal investments are strongly influenced by the actors' different required returns. With a relatively low required rate of return on energy investments, typical for a municipally owned utility, the most profitable investment is a wood chips-fuelled cogeneration plant. With a higher rate of return on capital, typical for a competitive industry, the optimal investment is mainly a heat-only steam boiler. Finally, some general influences on required rate of return caused by electricity market deregulation are observed. Whilst tending to increase companies' required returns, deregulation may, besides extending the outlet for locally generated electricity, also obstruct long-term high-cost investments such as cogeneration based on conventional technology

  19. Reactor waste heat utilization and district heating reactors. Nuclear district heating in Sweden - Regional reject heat utilization schemes and small heat-only reactors

    International Nuclear Information System (INIS)

    Hannerz, K.; Larsson, Y.; Margen, P.

    1977-01-01

    A brief review is given of the current status of district heating in Sweden. In future, district heating schemes will become increasingly interesting as a means of utilizing heat from nuclear reactors. Present recommendations in Sweden are that large reactors should not be located closer than about 20 km from large population centres. Reject heat from such reactors is cheap at source. To minimize the cost of long distance hot water transmission large heat rates must be transmitted. Only areas with large populations can meet this requirement. The three areas of main interest are Malmoe/Lund/Helsingborg housing close to 0.5 million; Greater Stockholm housing 1 to 1.5 million and Greater Gothenburg housing about 0.5 million people. There is an active proposal that the Malmoe/Lund/Helsingborg region would be served by a third nuclear unit at Barsebaeck, located about 20 km from Malmoe/Lund and supplying 950 MW of base load heat. Preliminary proposals for Stockholm involve a 2000 MW heat supply; proposals for Gothenburg are more tentative. The paper describes progress on these proposals and their technology. It also outlines technology under development to increase the economic range of large scale heat transport and to make distribution economic even for low heat-density family housing estates. Regions apart from the few major urban areas mentioned above require the adoption of a different approach. To this end the development of a small, simple low-temperature reactor for heat-only production suitable for urban location has been started in Sweden in close contact with Finland. Some results of the work in progress are presented, with emphasis on the safety requirements. An outline is given in the paper as to how problems of regional heat planning and institutional and legislative issues are being approached

  20. Combined Heat and Power Dispatch Considering Heat Storage of Both Buildings and Pipelines in District Heating System for Wind Power Integration

    Directory of Open Access Journals (Sweden)

    Ping Li

    2017-06-01

    Full Text Available The strong coupling between electric power and heat supply highly restricts the electric power generation range of combined heat and power (CHP units during heating seasons. This makes the system operational flexibility very low, which leads to heavy wind power curtailment, especially in the region with a high percentage of CHP units and abundant wind power energy such as northeastern China. The heat storage capacity of pipelines and buildings of the district heating system (DHS, which already exist in the urban infrastructures, can be exploited to realize the power and heat decoupling without any additional investment. We formulate a combined heat and power dispatch model considering both the pipelines’ dynamic thermal performance (PDTP and the buildings’ thermal inertia (BTI, abbreviated as the CPB-CHPD model, emphasizing the coordinating operation between the electric power and district heating systems to break the strong coupling without impacting end users’ heat supply quality. Simulation results demonstrate that the proposed CPB-CHPD model has much better synergic benefits than the model considering only PDTP or BTI on wind power integration and total operation cost savings.

  1. European municipalities and the liberalized energy market; Les municipalites europeennes et le marche liberalise de l'energie

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-04-01

    Municipalities are directly affected by the liberalization of the energy markets. Because they all consume or even produce energy, whether it be for their own consumption or to resell it, they often distribute gas, electricity or heat, they plan urban areas and organize the energy networks on their territory, while in addition citizens expect municipalities to inform them and even protect them against the possible excesses of energy salesmen. Elected representatives administrations, local agencies, municipal companies, citizens' associations etc., all have to innovate. This supplement to Energie-Cites INFO is intended to provide you with practical information and further analyses of the liberalization process. (authors)

  2. Can Britain afford to waste municipal waste and continue to make an unjustified contribution to the greenhouse effect?

    International Nuclear Information System (INIS)

    Lees, Byrom.

    1993-01-01

    In 1990, three papers were published relating to the emission of methane from municipal waste on landfill sites. They were by Munday, Lees and Manley. This report compares the data used in the above three reports published in 1990 and assesses the reasons for the different conclusions. Taking into account the most accurate assessment of methane emission from landfill sites and the latest information on the quantity of municipal waste being sent to landfill, suggestions are made of actions which could be taken in Britain to reduce the major contribution to the greenhouse effect of landfill gas and to utilise the potential heat in municipal waste, thus conserving fossil fuels. (author)

  3. Concept for urban heating systems using co-generation; Conception de systemes de chauffage urbain pour la cogeneration. Phase I: application au quartier des Morasses (Martigny) de la methode de conception des reseaux de chauffage urbain developpe au LENI. Rapport final

    Energy Technology Data Exchange (ETDEWEB)

    Cherix, G. [Centre de competence en urbistique CREM, Martigny (Switzerland); Weber, C. [Swiss Federal Institute of Technology (EPFL), Laboratoire d' energetique industrielle (LENI), Lausanne (Switzerland)

    2006-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) reviews the work done in the first phase of a project concerning the concept for a district heating system in Martigny, Switzerland. This work was carried out by the Centre for Municipal and Energy Research CREM in Martigny, Switzerland, and the Laboratory for Industrial Energy LENI at the Swiss Federal Institute of Technology in Lausanne. Software developed at the LENI is introduced and its use for the determination of the necessary configuration and modes of operation of a district heating system in Martigny is discussed. The situation in the Morasses district of Martigny and the promising results obtained are looked at. These can lead to the optimisation of heating supply in other such areas.

  4. Process and technological aspects of municipal solid waste gasification. A review

    International Nuclear Information System (INIS)

    Arena, Umberto

    2012-01-01

    Highlights: ► Critical assessment of the main commercially available MSW gasifiers. ► Detailed discussion of the basic features of gasification process. ► Description of configurations of gasification-based waste-to-energy units. ► Environmental performance analysis, on the basis of independent sources data. - Abstract: The paper proposes a critical assessment of municipal solid waste gasification today, starting from basic aspects of the process (process types and steps, operating and performance parameters) and arriving to a comparative analysis of the reactors (fixed bed, fluidized bed, entrained bed, vertical shaft, moving grate furnace, rotary kiln, plasma reactor) as well as of the possible plant configurations (heat gasifier and power gasifier) and the environmental performances of the main commercially available gasifiers for municipal solid wastes. The analysis indicates that gasification is a technically viable option for the solid waste conversion, including residual waste from separate collection of municipal solid waste. It is able to meet existing emission limits and can have a remarkable effect on reduction of landfill disposal option.

  5. Exergy and Energy Analysis of Low Temperature District Heating Network

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    is in line with a pilot project that is carrying out in Denmark with network supply/return temperature at 55oC/25 oC. The consumer domestic hot water (DHW) demand is supplied with a special designed district heating (DH) storage tank. The space heating (SH) demand is supplied with a low temperature radiator......Low temperature district heating (LTDH) with reduced network supply and return temperature provides better match of the low quality building thermal demand and the low quality waste heat supply. In this paper, an exemplary LTDH network was designed for 30 low energy demand residential houses, which....... The network thermal and hydraulic conditions were simulated under steady state with an in-house district heating network design and simulation code. Through simulation, the overall system energetic and exergetic efficiencies were calculated and the exergy losses for the major district heating system...

  6. Communal energy law. An outline. 2. ed.; Kommunales Energierecht. Darstellung

    Energy Technology Data Exchange (ETDEWEB)

    Henneke, Hans-Guenter; Ritgen, Klaus

    2013-08-01

    Ensuring a reliable, reasonably priced, environmentally friendly energy supply area-wide belongs to the most important public services that cities, administrative districts and municipalities are required to provide. In preparation of its second edition the present publication was thoroughly revised to do justice to the numerous legislative changes attending the energy turnaround. It presents the wide array of legal instruments at the disposal of municipalities for fulfilling their important duties in matters relating to the energy supply. It discusses the requirements of communal economic law as well as the constitutional and energy economy related framework conditions governing the energy supply. The concession contract, one of the most important instruments in the area of energy supply, has been given a chapter of its own. In regard to another of its focal topics the publication explains how municipal planning autonomy, especially in the area of land use planning, can help municipalities implement energy policies according to their own ideas. The publication concludes with a discussion of topics concerning municipalities as energy consumers, namely energy-related environmental law, the requirements of the Renewable Energy Heat Law and laws on energy saving.

  7. Municipal solid waste (MSW) as a renewable source of energy: current and future practices in China.

    Science.gov (United States)

    Cheng, Hefa; Hu, Yuanan

    2010-06-01

    With rapid economic growth and massive urbanization, China faces the problem of municipal solid waste (MSW) disposal and the pressing need for development of alternative energy. Waste-to-energy (WTE) incineration, which recovers energy from discarded MSW and produces electricity and/or steam for heating, is recognized as a renewable source of energy and is playing an increasingly important role in MSW management in China. This article provides an overview of the WTE industry, discusses the major challenges in expanding WTE incineration in China, namely, high capital and operational costs, equipment corrosion, air pollutant emissions, and fly ash disposal. A perspective on MSW as a renewable energy source in China is also presented. Currently, only approximately 13% of MSW generated in China is disposed in WTE facilities. With the significant benefits of environmental quality, the reduction of greenhouse gas (GHG) emissions, and government policies and financial incentives as a renewable energy source, WTE incineration industry is expected to experience significant growth in the coming decade and make greater contribution to supplying renewable energy in China. Copyright 2010 Elsevier Ltd. All rights reserved.

  8. Improved Economic Performance of Municipal Solid Waste Combustion Plants by Model Based Combustion Control

    NARCIS (Netherlands)

    Leskens, M.

    2013-01-01

    The combustion of municipal solid waste (MSW) is used for its inertisation, reduction of its volume and the conversion of its energy content into heat and/or electricity. Operation and control of modern large scale MSW combustion (MSWC) plants is determined by economic and environmental objectives

  9. Robust Water Supply Infrastructure Development Pathways: What, When and Where Matters the Most? (INVITED)

    Science.gov (United States)

    Reed, Patrick; Zeff, Harrison; Characklis, Gregory

    2017-04-01

    Water supply adaptation frameworks that seek robustness must adaptively trigger actions that are contextually appropriate to emerging system observations and avoid long term high regret lock-ins. As an example, emerging water scarcity concerns in southeastern United States are associated with several deeply uncertain factors, including rapid population growth, limited coordination across adjacent municipalities and the increasing risks for sustained regional droughts. Managing these uncertainties will require that regional water utilities identify regionally coordinated, scarcity-mitigating infrastructure development pathways that trigger time appropriate actions. Mistakes can lead to water shortages, overbuilt stranded assets and possibly financial failures. This presentation uses the Research Triangle area of North Carolina to illustrate the key concerns and challenges that emerged when helping Raleigh, Durham, Cary and Chapel Hill develop their long term water supply infrastructure pathways through 2060. This example shows how the region's water utilities' long term infrastructure pathways are strongly shaped by their short term conservation policies (i.e., reacting to evolving demands) and their ability to consider regional water transfers (i.e., reacting to supply imbalances). Cooperatively developed, shared investments across the four municipalities expand their capacity to use short term transfers to better manage severe droughts with fewer investments in irreversible infrastructure options. Cooperative pathways are also important for avoiding regional robustness conflicts, where one party benefits strongly at the expense of one or more the others. A significant innovation of this work is the exploitation of weekly and annual dynamic risk-of-failure action triggers that exploit evolving feedbacks between co-evolving human demands and regional supplies. These dynamic action triggers provide high levels of adaptivity, tailor actions to their specific context

  10. Projected configuration of a coal-fired district heating source on the basis of comparative technical-economical optimization analysis

    Directory of Open Access Journals (Sweden)

    Tańczuk Mariusz

    2017-01-01

    Full Text Available District heating technologies should be efficient, effective and environmentally friendly. The majority of the communal heating systems in Poland produce district hot water in coal-fired boilers. A large number of them are considerably worn out, low-efficient in the summer time and will not comply with forthcoming regulations. One of the possible solution for such plants is repowering with new CHP systems or new boilers fuelled with fuels alternative to coal. Optimisation analysis of the target configuration of municipal heat generating plant is analysed in the paper. The work concerns repowering the existing conventional heat generating plant according to eight different scenarios of the plant configuration meeting technical and environmental requirements forecasted for the year of 2035. The maximum demand for heat of the system supplied by the plant is 185 MW. Taking into account different technical configurations on one side, and different energy and fuel prices on the other side, the comparative cost-benefits analysis of the assumed scenarios has been made. The basic economical index NPV (net present value has been derived for each analysed scenario and the results have been compared and discussed. It was also claimed that the scenario with CHP based on ICE engines is optimal.

  11. Projected configuration of a coal-fired district heating source on the basis of comparative technical-economical optimization analysis

    Science.gov (United States)

    Tańczuk, Mariusz; Radziewicz, Wojciech; Olszewski, Eligiusz; Skorek, Janusz

    2017-10-01

    District heating technologies should be efficient, effective and environmentally friendly. The majority of the communal heating systems in Poland produce district hot water in coal-fired boilers. A large number of them are considerably worn out, low-efficient in the summer time and will not comply with forthcoming regulations. One of the possible solution for such plants is repowering with new CHP systems or new boilers fuelled with fuels alternative to coal. Optimisation analysis of the target configuration of municipal heat generating plant is analysed in the paper. The work concerns repowering the existing conventional heat generating plant according to eight different scenarios of the plant configuration meeting technical and environmental requirements forecasted for the year of 2035. The maximum demand for heat of the system supplied by the plant is 185 MW. Taking into account different technical configurations on one side, and different energy and fuel prices on the other side, the comparative cost-benefits analysis of the assumed scenarios has been made. The basic economical index NPV (net present value) has been derived for each analysed scenario and the results have been compared and discussed. It was also claimed that the scenario with CHP based on ICE engines is optimal.

  12. The Impact on Wind Power Integration from Geothermal Absorption

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2012-01-01

    and lowtemperature geothermal resources. The analyses have also demonstrated that the municipality will still rely heavily on surrounding areas for electric load balancing assistance. With a departure in a previously elaborated 100% renewable energy scenario, this paper investigates how absorption heat pumps (AHP......Aalborg Municipality, Denmark is investigating ways of switching to 100 % renewable energy supply over the next 40 years. Analyses so far have demonstrated a potential for such a transition through energy savings, district heating (DH) and the use of locally available biomass, wind power......) and compression heat pumps (HP) for the supply of DH impact the integration of wind power. Hourly scenarioanalyses made using the EnergyPLAN model reveal a boiler production and electricity excess which is higher with AHPs than with HPs whereas condensing mode power generation is increased by the application...

  13. GENERALIZATION, FORMULATION AND HEAT CONTENTS OF SIMULATED MSW WITH HIGH MOISTURE CONTENT

    Directory of Open Access Journals (Sweden)

    A. JOHARI

    2012-12-01

    Full Text Available This paper presents a generalization technique for the formulation of simulated municipal solid waste. This technique is used for the elimination of the inconsistency in the municipal solid waste (MSW characteristics due to its heterogeneous nature. The compositions of simulated municipal solid waste were formulated from four major municipal waste streams components in Malaysia namely paper, plastic, food and yard waste. The technique produced four simplified waste generalization categories with composition of paper (19%, plastic (25%, food (27% and green waste (29% respectively. Comparative study was conducted for proximate analysis for the determination of volatile matter, fixed carbon and ash content. Ultimate analysis was performed for carbon and hydrogen content. The heat content for simulated and actual municipal solid waste showed good agreement. The moisture content of the simulated municipal solid waste and actual municipal solid waste were established at 52.34% and 61.71% respectively. Overall results were considered to be representative of the actual compositions of municipal solid waste in Malaysia.

  14. Carbon Footprint Analysis of Municipalities – Evidence from Greece

    Directory of Open Access Journals (Sweden)

    K. Angelakoglou

    2015-11-01

    Full Text Available The economical crisis that hit Greece after 2009, significantly affected its energy consumption profile due to the increased price of domestic heating oil and gasoline. The specific study aims at the quantification of the carbon dioxide emissions in municipal level due to energy and fuel consumption. Three different municipalities in North Greece (Kavala, Alexandroupolis and Drama were assessed with the application of three different carbon footprint estimation approaches in each one of them, including two life cycle assessment methods. Results ranged from 511,799 to 571,000, 435,250 to 489,000 and 355,207 to 398,000 tons CO2 and tons CO2-eq. for Kavala, Alexandroupolis and Drama respectively. The analysis per energy type indicated the electrical energy consumption as the key factor affecting the results due to the relatively high CO2 emission coefficient of the electricity produced in Greece. The analysis per sector indicated that a percentage of nearly 75% of the total carbon footprint is assigned to the building sector whereas the private and commercial transport is accountable for the rest. Municipal activities (buildings, facilities, lighting and fleet contributed to a small percentage to the total carbon footprint (approx. 3-8%.

  15. Energy saving type area hot water supply system using heat of hot waste water from the sludge center as hot source for hot water; New energy rokko airando CITY. Surajjisenta karano onhaisuinetsu wo kyuyuyo netsugen ni riyosuru sho energy gata chiiki onsui kyokyu system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    Heat source of area hot water supply system in Rokko island City (man-made island) is heat of combustion at the sludge center (sludge incineration plant) in this island. Dehydrated sludge cakes (230ton/day) brought from seven sewage disposal plants in Kobe City is combusted (850degC) in the fluid bed hearth. Combustion gas washed in the scrubber, hot waste water after the washing give heat into heat transfer water in the first heat exchanger. Temperature being 64degC in summer and about 50degC in winter, this heat transfer water is sent into the second heat exchanger at every condominium building throughout the pipe line system circulating in the area. At each home, gas heater and hot water supply devices fitted, additional combustion is not necessary in summer but is used according to demand in other seasons. This hot water supply service has been carried out since 1988 and at present has been used by 3600 homes. Amount of supplying hot water being about 3000cu.m/day, saving is calculated roughly as 60% of gas for hot water supply. Fee for this system is 1500/yen/month uniformly for each home. 14 figs.

  16. The Energy, Greenhouse Gas Emissions, and Cost Implications of Municipal Water Supply & Wastewater Treatment

    Science.gov (United States)

    Rodriguez-Winter, Thelma

    All man-made structures and materials have a design life. Across the United States there is a common theme for our water and wastewater treatment facilities and infrastructure. The design life of many of our mid 20 th century water and wastewater infrastructures in the United States have reached or are reaching life expectancy limits (ASCE, 2010). To compound the financial crisis of keeping up with the degradation, meeting and exceeding quality standards has never been more important in order to protect local fresh water supplies. This thesis analyzes the energy consumption of a municipal water and wastewater treatment system from a Lake Erie intake through potable treatment and back through wastewater treatment then discharge. The system boundary for this thesis includes onsite energy consumed by the treatment system and distribution/reclamation system as well as the energy consumed by the manufacturing of treatment chemicals applied during the study periods. By analyzing energy consumption, subsequent implications from greenhouse gas emissions and financial expenditures were quantified. Through the segregation of treatment and distribution processes from non-process energy consumption, such as heating, lighting, and air handling, this study identified that the potable water treatment system consumed an annual average of 2.42E+08 kBtu, spent 5,812,144 for treatment and distribution, and emitted 28,793 metric tons of CO2 equivalent emissions. Likewise, the wastewater treatment system consumed an annual average of 2.45E+08 kBtu, spent 3,331,961 for reclamation and treatment, and emitted 43,780 metric tons of CO2 equivalent emissions. The area with the highest energy usage, financial expenditure, and greenhouse gas emissions for the potable treatment facility and distribution system was from the manufacturing of the treatment chemicals, 1.10E+08 kBtu, 3.7 million, and 17,844 metric tons of CO2 equivalent, respectively. Of the onsite energy (1.4E-03 kWh per gallon

  17. Effective by combination. Biogas plant Niederweiler supplies two heating grids, directly exploits its electric power commercially and also supplies the balancing energy; Effektiv durch Kombinieren. Biogasanlage Niederweiler versorgt zwei Waermenetze, vermarktet ihren Strom direkt und stellt jetzt auch Regelenergie zur Verfuegung

    Energy Technology Data Exchange (ETDEWEB)

    Lennartz, Marc Wilhelm

    2013-07-01

    In the Eifel (Federal Republic of Germany) an agricultural consortium took over the heat supply of a hotel complex with a satellite cogeneration plant. Thus, the capacity for flexible power feed was set free.

  18. Organic school meals in three Danish municipalities

    DEFF Research Database (Denmark)

    He, Chen

    In order to prevent children and young people from becoming overweight or obese, it is imperative to promote healthier eating patterns. So it is necessary to develop and implement effective strategies that can influence the eating and lifestyle habits of young people. Healthy school meal programme...... is considered to be an effective strategy to promote such changes and increasingly such strategies become embedded organic supply polices and strategies that pursue environmental goals. The purpose of this paper is to take a closer look into the current status of the organic school meal programme in Denmark....... Three municipalities which are involved in the organic school meal programme are chosen as the study subjects....

  19. Esco in Danish municipalities

    DEFF Research Database (Denmark)

    Jensen, Jesper Ole; Hansen, Jesper Rohr; Nielsen, Susanne Balslev

    2012-01-01

    Purpose: The aim of this paper is to discuss the possible benefits of involving Energy Service Companies (ESCO) in realising energy savings in municipalities, and how ESCO projects can be formulated very differently in the various municipalities, according to building volume, use of technologies......, energy savings, type of collaboration etc. Background: Since 2008, several Danish municipalities have started energy retrofitting of municipal buildings, based on contracts with Energy Service Companies. In spite of the strong growth of ESCOs, there is also widespread scepticism about ESCO, as many...... approaches are being used in Danish municipalities, which we label the basic, the integrated and the strategic ESCO approaches. The three approaches include different ambitions, technologies, economies and innovation potentials. Whereas the basic approach implies a ‘traditional’ guarantee-based model...

  20. Realisation of a small hydro power plant in the new water reservoir of the water supply of the San Abbondio municipality; Realizzazione di una microcentrale nel nuovo serbatoio dell'acquedotto del comune di S. Abbondio. Progetto definitivo nuovo serbatoio. Progetto di massima e studio varianti microcentrale

    Energy Technology Data Exchange (ETDEWEB)

    Conti, M.

    2008-12-15

    This report for the Swiss Federal Office of Energy (SFOE) presents the construction project of a new water reservoir including a micro-scale hydro power plant in the drinking-water supply of the municipality of San Abbondio, Switzerland. Following the development of residential areas a new water reservoir located at higher elevation is needed. A former preliminary study had demonstrated the feasibility of a micro-scale hydro power plant in the water supply. The adaptation of the plant design to the new situation is described. Investment cost is estimated and several variants are compared. Recommendations are given to the authorities.

  1. Adaptive municipal electronic forms

    NARCIS (Netherlands)

    Kuiper, Pieternel; van Dijk, Elisabeth M.A.G.; Bondarouk, Tatiana; Ruel, Hubertus Johannes Maria; Guiderdoni-Jourdain, Karine; Oiry, Ewan

    Adaptation of electronic forms (e-forms) seems to be a step forward to reduce the burden for people who fill in forms. Municipalities more and more offer e-forms online that can be used by citizens to request a municipal product or service or by municipal employees to place a request on behalf of a

  2. Organisation of municipal gas supply; Organisation einer kommunalen Gasversorgung. Theoretische und praktische Betrachtungen

    Energy Technology Data Exchange (ETDEWEB)

    Wolters, T.

    2000-07-01

    A safe supply of gas requires more than technically secure facilities and components. A structured and suitable organisation of the company's set-up and proceeding is necessary as well. In a diploma thesis, which was honored by the DVGW, theses aspects were treated as well in theory as well as in examples. Finally, a proposel for a gas supply company was developed which offered to translate into practice the results of the thesis. The thesis discusses issues of maintaining gas supply facilities and issues of the faultclearing service as well as aspects of the worker's protection laws. (orig.) [German] Eine sichere Gasversorgung verlangt mehr als technisch sichere Anlagen und Komponenten. Hierzu ist auch besonders eine planvolle und angemessene Aufbauorganisation und Ablauforganisation des Unternehmens notwendig. In einer vom DVGW ausgezeichneten Diplomarbeit wurden diese Aspekte theoretisch und an Beispielen erarbeitet, um letztlich einem Gasversorgungsunternehmen einen konkreten Vorschlag fuer die Umsetzung des Erarbeiteten zu unterbreiten. Fragen der Instandhaltung von Gasversorgungsanlagen und des Entstoerdienstes finden ebenso Beachtung wie die Umsetzung von Forderungen aus der Arbeitsschutzgesetzgebung. (orig.)

  3. Including solar energy in the local heat supply of the Goettingen city works; Einbindung von Sonnenenergie in die Nahwaermeversorgung der Stadtwerke Goettingen AG

    Energy Technology Data Exchange (ETDEWEB)

    Tepe, R. [ISFH - Institut fuer Solarenergieforschung Hameln-Emmerthal GmbH, Emmerthal (Germany); Schreitmueller, K.R. [ISFH - Institut fuer Solarenergieforschung Hameln-Emmerthal GmbH, Emmerthal (Germany); Vanoli, K. [ISFH - Institut fuer Solarenergieforschung Hameln-Emmerthal GmbH, Emmerthal (Germany)

    1996-11-01

    The research project `Solar local heat Goettingen` was started in 1992 in which, by including a 785 m{sup 2} flat collector plant in the return of the local heat supply of the Goettingen City Works; the potential of the combined system of solar plant and conventional heat supply system is to be proved. The size of the collector plant and inclusion in an existing local heat network promised an advantageous combination due to appreciably lower investment costs (lower collector installation costs) and savings in system technique, reduced operating costs, and higher income due to favourable operating conditions with even low collector operating temperatures and reduced piping losses. In parallel with this system, the Goettingen City Works installed an air collector plant which is used to preheat the combustion air taken to the conventional burners. (orig./HW) [Deutsch] Es entstand im Jahr 1992 das Forschungsvorhaben `Solare Nahwaerme Goettingen`, in dem durch die Einbindung einer 785 m{sup 2} grossen Flachkollektoranlage in den Ruecklauf der Nahwaermeversorgung der Stadtwerke Goettingen AG das Potential der Systemkombination Solaranlage und konventionelle Waermeversorgungssystem nachgewiesen werden sollte. Die Groesse der Kollektoranlage sowie die Einbindung in ein bestehendes Nahwaermenetz versprachen eine vorteilhafte Kombination aufgrund - deutlich geringerer Investionskosten (geringe Kollektorinstallationskosten sowie Einsparungen bei der Systemtechnik); - reduzierter Betriebskosten; - hoher Ertraege durch guenstige Betriebsbedingungen wie gleichbleibend niedriger Kollektorbetriebstemperaturen und reduzierter Leitungsverluste. Parallel zu diesem System installierten die Stadtwerke Goettingen AG eine Luftkollektoranlage, die der Vorwaermung der den konventionellen Brennern zugefuehrten Verbrennungsluft dient. (orig./HW)

  4. Heat contracting - a contribution to climate protection, security of supply and competition; Waerme-Contracting - ein Beitrag zu Klimaschutz, Versorgungssicherheit und Wettbewerb

    Energy Technology Data Exchange (ETDEWEB)

    Quint, R.P. [GASAG WaermeService GmbH, Berlin (Germany)

    2007-08-15

    Contracting is an important trump card when it comes to containing the climate change and improving the security of supply - and a promising business field besides. This is an option that should be used more widely considering the ambitious energy efficiency improvement targets of the European Union and Germany, which are set at 20% and 50% percent over the year 1990, respectively. It is moreover an option that pays off. German tenancy law is in urgent need of a reform to make heat contracting more popular. Furthermore, the modernisation of heating systems through contracting should be placed on a level with modernisation effected by the landlord.

  5. Licensing fees in the district heating industry; Gestattungsentgelte in der Fernwaermewirtschaft

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Norman [Jena Univ. (Germany)

    2009-10-15

    By means of licensing agreements municipalities grant the right to the district heating suppliers to use their properties with or without fees for the construction of district heating pipelines. Contrary to the power industry or gas industry, this type of contract is not regulated by special legal and price-legal regulations. Often an uncertainty exists whether and in which amount the municipalities may require a return for the right of utilization. In particular, this is valid if municipalities make the extension of discontinued licensing agreements dependent on the agreement of higher license fees. The general review under consideration reports on any legal limits of the amount of the licence fees. At the same time, a reference to licence fees in the power sector and gas sector is performed. In addition, the author reports on the law historical and law political background of license fees.

  6. Performance of ultra low temperature district heating systems with utility plant and booster heat pumps

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Thorsen, Jan Eric; Markussen, Wiebke Brix

    2017-01-01

    The optimal integration of booster heat pumps in ultra low temperature district heating (ULTDH) was investigated and compared to the performance of low temperature district heating. Two possible heat production technologies for the DH networks were analysed, namely extraction combined heat...... temperature and the heat consumption profile. For reference conditions, the optimal return of ULTDH varies between 21 °C and 27 °C. When using a central HP to supply the DH system, the resulting coefficient of system performance (COSP) was in the range of 3.9 (-) to 4.7 (-) for equipment with realistic...... component efficiencies and effectiveness, when including the relevant parameters such as DH system pressure and heat losses. By using ULTDH with booster HPs, performance improvements of 12% for the reference calculations case were found, if the system was supplied by central HPs. Opposite results were found...

  7. Microwave heating type evaporator

    International Nuclear Information System (INIS)

    Taura, Masazumi; Nishi, Akio; Morimoto, Takashi; Izumi, Jun; Tamura, Kazuo; Morooka, Akihiko.

    1987-01-01

    Purpose: To prevent evaporization stills against corrosion due to radioactive liquid wastes. Constitution: Microwaves are supplied from a microwave generator by way of a wave guide tube and through a microwave permeation window to the inside of an evaporatization still. A matching device is attached to the wave guide tube for transmitting the microwaves in order to match the impedance. When the microwaves are supplied to the inside of the evaporization still, radioactive liquid wastes supplied from a liquid feed port by way of a spray tower to the inside of the evaporization still is heated and evaporated by the induction heating of the microwaves. (Seki, T.)

  8. Solar-heated municipal swimming pools, a case study: Dade County, Florida

    Science.gov (United States)

    Levin, M.

    1981-09-01

    The installation of a solar energy system to heat the water in the swimming pool in one of Dade County, Florida's major parks is described. The mechanics of solar heated swimming pools are explained. The solar heating system consists of 216 unglazed polypropylene tube collectors, a differential thermostat, and the distribution system. The systems performance and economics as well as future plants are discussed.

  9. Resource Prospects of Municipal Solid Wastes Generatedin the Ga East Municipal Assembly of Ghana

    OpenAIRE

    Benedicta Abiti; Susanne Hartard; Heike B. Bradl; Davar Pishva; John Kojo Ahiakpa

    2017-01-01

    Background. Municipal solid wastes management has recently become an important public health concern. Municipal solid wastes are a major source of raw materials that could be used for resource recovery for diverse applications. Objectives. The present study aimed to determine the composition of municipal solid waste and recoverable resources from the waste of the Ga East Municipal Assembly (GEMA) in the Greater Accra region of Ghana. Methods. An exploratory approach was used to collect ...

  10. A local heating system using wood fuel from farms

    International Nuclear Information System (INIS)

    Kiukaanniemi, E.; Kurvinen, T.

    1998-01-01

    This report is a part of the a project on sustainable biomass utilization chains. The project belongs to a larger group of studies on northern biomass utilization by the Thule Institute and the University of Oulu. A cooperative energy society working in the municipality of Perho (3400 inhabitants) in Finland has been studied in this report. The cooperative energy society delivers energy which is generated from wood chips to the Perho municipality. Generated energy has a competitive price compared with fuel oils. In addition, harvesting, chipping and transporting give the members of the society an extra income. Members need not to make any investments in new equipment in order to work in the co-operative society because the machinery needed is the same as the one they use for other forestry activities. The price of the energy generated by wood chips is bound to the price of alternative fuels. There is a 5 MW district heating plant in Perho municipality containing a 1.4 MW solid fuel fired boiler with grate and 1.6 MW and 2.0 MW oil fired boilers. An investment in a heating plant containing a solid fuel fired boiler is often many times greater than that of one containing an oil fired boiler. There are many advantages which are hard to evaluate in generating energy from wood fuel. E.g. employment, increased income from taxes, an increase in the cash flow in the municipality and the advantages for forest growth. When undersized trees are removed from a forest stand, the remaining trees will grow better. The advantage of forestry is, however, hard to evaluate in cash terms. There has been an estimate that the advantage is 50-100 FIM/ha/a when compared to the yield of unthinned pine forest. Studies have shown that the money paid for energy in the area may be recycled several times in purchasing products and services in the area. In Perho municipality, it has been estimated that over half million FIM of extra cash has been generated and invested in the area by the

  11. Waste Sites - Municipal Waste Operations

    Data.gov (United States)

    NSGIC Education | GIS Inventory — A Municipal Waste Operation is a DEP primary facility type related to the Waste Management Municipal Waste Program. The sub-facility types related to Municipal Waste...

  12. Nuclear district heating. 1. Process heat reactors and transmission and distribution networks

    International Nuclear Information System (INIS)

    Caizergues, R.

    1979-01-01

    Three kinds of production station are considered: joint electricity and heat-producing stations, heat-producing stations with CAS reactors and heat-producing stations with Thermos reactors. The thermal energy supply possibilities of these stations, the cost price of this energy and the cost price per therm produced by the district heating source and conveyed to the user are studied [fr

  13. Arsenic in public water supplies and cardiovascular mortality in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Medrano, Ma Jose, E-mail: pmedrano@isciii.es [Centro Nacional de Epidemiologia, Instituto de Salud Carlos III, Sinesio Delgado 6, 28029 Madrid (Spain); Boix, Raquel; Pastor-Barriuso, Roberto [Centro Nacional de Epidemiologia, Instituto de Salud Carlos III, Sinesio Delgado 6, 28029 Madrid (Spain); Palau, Margarita [Subdireccion General de Sanidad Ambiental y Salud Laboral, Direccion General de Salud Publica y Sanidad Exterior, Ministerio de Sanidad y Politica Social, Madrid (Spain); Damian, Javier [Centro Nacional de Epidemiologia, Instituto de Salud Carlos III, Sinesio Delgado 6, 28029 Madrid (Spain); Ramis, Rebeca [Centro Nacional de Epidemiologia, Instituto de Salud Carlos III, Sinesio Delgado 6, 28029 Madrid (Spain); CIBER en Epidemiologia y Salud Publica (CIBERESP), Madrid (Spain); Barrio, Jose Luis del [Departamento de Salud Publica, Universidad Rey Juan Carlos, Madrid (Spain); Navas-Acien, Ana [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD (United States); Department of Epidemiology, Welch Center for Prevention, Epidemiology and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD (United States)

    2010-07-15

    water were associated with increased cardiovascular mortality at the municipal level. Prospective cohort studies with individual measures of arsenic exposure, standardized cardiovascular outcomes, and adequate adjustment for confounders are needed to confirm these ecological findings. Our study, however, reinforces the need to implement arsenic remediation treatments in water supply systems above the World Health Organization safety standard of 10 {mu}g/L.

  14. Control system of power supply for resistance welding machine

    Directory of Open Access Journals (Sweden)

    Світлана Костянтинівна Поднебенна

    2017-06-01

    Full Text Available This article describes the existing methods of heat energy stabilizing, which are realized in thyristor power supplies for resistance welding machines. The advantages and features of thyristor power supplies have been described. A control system of power supply for resistance welding machine with stabilization of heat energy in a welding spot has been developed. Measurements are performed in primary winding of a welding transformer. Weld spot heating energy is calculated as the difference between the energy, consumed from the mains, and the energy losses in the primary and secondary circuits of the welding transformer as well as the energy losses in the transformer core. Algorithms of digital signal processing of the developed control system are described in the article. All measurements and calculations are preformed automatically in real-time. Input signals to the control system are: transformer primary voltage and current, temperature of the welding circuit. The designed control system ensures control of the welding heat energy and is not influenced by the supply voltage and impedance changes caused by insertion of the ferromagnetic mass in the welding circuit, the temperature change during the welding process. The developed control system for resistance welding machine makes it possible to improve the quality of welded joints, increase the efficiency of the resistance welding machine

  15. Disinfection of municipal water using solar radiation: an economical approach for rural dwellers in the coastal region of Karachi

    International Nuclear Information System (INIS)

    Ahmed, M.F.; Saleem, M.

    2010-01-01

    At present acquiring safe drinking water in rural or remote areas of Pakistan is a challenging task for dwellers. Coast line of Karachi is a sporadic habitat of villages not having access to safe drinking water. Many incidents of waterborne diseases have been reported in that area and attributed to contaminated municipal water supply. Solution of the problem is disinfection however, general methods of water disinfection such as boiling, UV-lamp, ozonation and chemical additive are costly or require skilled manpower. Present study investigates the solar disinfection method to treat municipal water supply at Karachi Institute of Power Engineering (KINPOE) located at the coastal belt of Karachi. Effect of exposure time, bottle material and turbidity of water on the process performance was evaluated. Model indicator bacteria total coliform (TC) was used to evaluate the solar disinfection process. Study revealed that in order to disinfect the municipal water, samples should be filled in PET transparent bottles, having turbidity below 23 NTU, and expose to solar radiation in the study area at least for one hour. Study shows that solar disinfection may provide safe drinking water meeting national and international water quality standards at minimum cost and effort in sunshine rich areas and not having access to other water purification systems. (author)

  16. Influence of short heat pulses on the helium boiling heat transfer rate

    International Nuclear Information System (INIS)

    Andreev, V.K.; Deev, V.I.; Savin, A.N.; Kutsenko, K.V.

    1987-01-01

    Investigation results on heat transfer in the process of helium boiling on a heated wall under conditions of pulsed heat effect are described. Results of the given study point to one of possible ways of heat exchange intensification in boiling helium by supplying short heat pulse to the heater. Even short-time noncontrolled or incidental increase in the heater capacity during experiment with boiling helium can result in a considerable disagreement of experimental data on heat transfer

  17. Research on Comprehensive Evaluation Method for Heating Project Based on Analytic Hierarchy Processing

    Science.gov (United States)

    Han, Shenchao; Yang, Yanchun; Liu, Yude; Zhang, Peng; Li, Siwei

    2018-01-01

    It is effective to reduce haze in winter by changing the distributed heat supply system. Thus, the studies on comprehensive index system and scientific evaluation method of distributed heat supply project are essential. Firstly, research the influence factors of heating modes, and an index system with multiple dimension including economic, environmental, risk and flexibility was built and all indexes were quantified. Secondly, a comprehensive evaluation method based on AHP was put forward to analyze the proposed multiple and comprehensive index system. Lastly, the case study suggested that supplying heat with electricity has great advantage and promotional value. The comprehensive index system of distributed heating supply project and evaluation method in this paper can evaluate distributed heat supply project effectively and provide scientific support for choosing the distributed heating project.

  18. An analysis of Water Supply Heat Pump's Capability of Energy Storage and Energy Saving Using Electricity%水源热泵系统蓄能节能的可行性

    Institute of Scientific and Technical Information of China (English)

    吴薇; 张小松

    2002-01-01

    In this paper, the characteristic of water supply heat pump (WLHP) is introduced. The thermal performanceand effect of energy saving that can be used to heating and cooling at the same time (the distinctive working mode) is em-phasized. A new idea of heat input using wave trough electricity instead of boilers is brought up, the effect and significance ofthis new method is discussed.

  19. Fiscal 1974 Sunshine Project result report. Research on solar cooling/heating and hot water supply system; 1974 nendo taiyonetsu reidanbo kyuto system no kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-03-01

    This report describes the fiscal 1974 research result on solar cooling/heating and hot water supply system. This 3- year project from fiscal 1974 to 1976 aims to predict the share of solar energy in future cooling/heating and hot water supply energy demand, and develop simulation technology. The project surveys and analyzes current domestic and overseas development states, and studies various systems to obtain characteristics of every system, pursuit an optimum implementation, and establish a diffusion plan. Future energy consumptions and prices are predicted in relation to energy saving, and the utilization impact of solar energy is analyzed. Study is also made on diffusion plan, profitability and performance evaluation method. Among these schedules, in fiscal 1974 based on the survey and analysis on previous domestic and overseas development states, features and problems were arranged every system and application. The basic study on system simulation, and rough feasibility study on solar heat systems by conventional technique were carried out. The basic data on performance evaluation standards were also prepared. (NEDO)

  20. Using Water Transfers to Manage Supply Risk

    Science.gov (United States)

    Characklis, G. W.

    2007-12-01

    Most cities currently rely on water supplies with sufficient capacity to meet demand under almost all conditions. However, the rising costs of water supply development make the maintenance of infrequently used excess capacity increasingly expensive, and more utilities are considering the use of water transfers as a means of more cost effectively meeting demand under drought conditions. Transfers can take place between utilities, as well as different user groups (e.g., municipal and agricultural), and can involve both treated and untreated water. In cases where both the "buyer" and "seller" draw water from the same supply, contractual agreements alone can facilitate a transfer, but in other cases new infrastructure (e.g., pipelines) will be required. Developing and valuing transfer agreements and/or infrastructure investments requires probabilistic supply/demand analyses that incorporate elements of both hydrology and economics. The complexity of these analyses increases as more sophisticated types of agreements (e. g., options) are considered, and as utilities begin to consider how to integrate transfers into long-term planning efforts involving a more diversified portfolio of supply assets. This discussion will revolve around the methods used to develop minimum (expected) cost portfolios of supply assets that meet specified reliability goals. Two different case studies, one in both the eastern and western U.S., will be described with attention to: the role that transfers can play in reducing average supply costs; tradeoffs between costs and supply reliability, and; the effects of different transfer agreement types on the infrastructure capacity required to complete the transfers. Results will provide insights into the cost savings potential of more flexible water supply strategies.