WorldWideScience

Sample records for municipal heat supply

  1. Scenarios for sustainable heat supply and heat savings in municipalities - the case of Helsingør, Denmark

    DEFF Research Database (Denmark)

    Ben Amer-Allam, Sara; Münster, Marie; Petrovic, Stefan

    2017-01-01

    Local climate action is not only a domain of large cities, but also smaller urban areas that increasingly address climate change mitigation in their policy. The Danish municipality of Helsingør can achieve a substantial CO2 emissions reduction by transforming its heat supply and deploying heat...... savings. In this paper, we model the heating system of Helsingør, assess it from a simple socio- and private-economic perspective, develop future scenarios, and conduct an iterative process to derive a cost-optimal mix between district heating, individual heating and heat savings. The results show...... of heating and/or cooling supply for different demand configurations, geographical region and scale....

  2. Heat supply from municipal solid waste incineration plants in Japan: Current situation and future challenges.

    Science.gov (United States)

    Tabata, Tomohiro; Tsai, Peii

    2016-02-01

    The use of waste-to-energy technology as part of a municipal solid waste management strategy could reduce the use of fossil fuels and contribute to prevention of global warming. In this study, we examined current heat and electricity production by incineration plants in Japan for external use. Herein, we discuss specific challenges to the promotion of heat utilisation and future municipal solid waste management strategies. We conducted a questionnaire survey to determine the actual conditions of heat production by incineration plants. From the survey results, information of about 498 incineration plants was extracted. When we investigated the relationship between heat production for external use and population density where incineration plants were located, we found that regions with a population density situation. © The Author(s) 2015.

  3. 40 CFR 230.50 - Municipal and private water supplies.

    Science.gov (United States)

    2010-07-01

    ... a municipal or private water supply system. (b) Possible loss of values: Discharges can affect the... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Municipal and private water supplies... Potential Effects on Human Use Characteristics § 230.50 Municipal and private water supplies. (a) Municipal...

  4. Optimal supply and demand investments in municipal energy systems

    International Nuclear Information System (INIS)

    Rolfsman, Bjoern

    2004-01-01

    In many municipalities, there are district heating networks, which are quite commonly supplied by combined heat and power plants (CHP). A district heating network contains buildings of different types. In this paper, one such municipal energy system is analysed. In order to provide space heating and domestic hot water, investments could be made on the supply side in power plants, or on the demand side in the buildings, for example in the form of extra wall insulation. The electricity from the CHP plants is supplied to the municipality but can also be sold to the electricity market, and electricity can, of course, also be bought from the market. The variation in price on the spot market over any given day is significant. The need for district heat in the building stock also varies, for example due to climatic conditions. The energy system in the case study is analysed with a mixed integer linear programming model. The model has 3 h time steps in order to reflect diurnal variations, and an entire year is analysed. A case study is presented for the city of Linkoeping in Sweden. On the demand side, the options are: extra wall insulation, extra attic insulation and better types of windows. The building stock is divided into nine categories

  5. Remediation System Evaluation, Savage Municipal Water Supply Superfund Site (PDF)

    Science.gov (United States)

    The Savage Municipal Water Supply Superfund Site, located on the western edge of Milford, New Hampshire, consists of a source area and an extended plume that is approximately 6,000 feet long and 2,500 feet wide.

  6. Master plan study - District heating Sillamaee municipality. Estonia. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The main deficiencies of the district heating system in Sillamae (Estonia) were identified as being inefficiency of the heat and power production plant, which has a very low capacity, lack of means for consumers to control their energy consumption due to the existing constant flow system, pollution from heat and power production based on oil shale, water and heat losses from the network and unclear agreements between the Silmet factory and Sillamae municipality. The available capital for funding is limited. It was investigated where in the system investments would have the greatest effect. A scenario where heat is supplied from individual gas-fired boilers was calculated. A financially viable scenario would be to change from cogeneration of heat and power (CHP) based on oil shale to either individual natural gas supply or peat-fueled heat production. The Sillamae municipality and the Estonian government should agree on a solution for Sillamae. There will be a cash flow problem if the project is implemented. This can be partly solved by introducing a longer loan period. it is expected that there will be no substantial changes in the consumers` heat demand in the `do nothing`scenario, and in other scenarios ca. 520 Tj/p.a. from the Solmet factory, 530 Tj/p.a. from the town and 260 Tj/p.a. as heat losses, totaling 1310 Tj/p.a.. In another scenario - the introduction of natural gas - the town`s heat demand will be 530 Tj/p.a. and there will be no heat losses. More detailed studies of environmental impacts should be undertaken. (ARW)

  7. Master plan study - District heating Sillamaee municipality. Estonia. Final report

    International Nuclear Information System (INIS)

    1997-03-01

    The main deficiencies of the district heating system in Sillamae (Estonia) were identified as being inefficiency of the heat and power production plant, which has a very low capacity, lack of means for consumers to control their energy consumption due to the existing constant flow system, pollution from heat and power production based on oil shale, water and heat losses from the network and unclear agreements between the Silmet factory and Sillamae municipality. The available capital for funding is limited. It was investigated where in the system investments would have the greatest effect. A scenario where heat is supplied from individual gas-fired boilers was calculated. A financially viable scenario would be to change from cogeneration of heat and power (CHP) based on oil shale to either individual natural gas supply or peat-fueled heat production. The Sillamae municipality and the Estonian government should agree on a solution for Sillamae. There will be a cash flow problem if the project is implemented. This can be partly solved by introducing a longer loan period. it is expected that there will be no substantial changes in the consumers' heat demand in the 'do nothing'scenario, and in other scenarios ca. 520 Tj/p.a. from the Solmet factory, 530 Tj/p.a. from the town and 260 Tj/p.a. as heat losses, totaling 1310 Tj/p.a.. In another scenario - the introduction of natural gas - the town's heat demand will be 530 Tj/p.a. and there will be no heat losses. More detailed studies of environmental impacts should be undertaken

  8. Wind power integration in Aalborg Municipality using compression heat pumps and geothermal absorption heat pumps

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2013-01-01

    -temperature geothermal resources. The analyses have also demonstrated that the municipality will still rely heavily on surrounding areas for electric load balancing assistance. With a departure in a previously elaborated 100% renewable energy scenario, this article investigates how absorption heat pumps (AHP......Aalborg Municipality, Denmark is investigating ways of switching to 100% renewable energy supply over the next 40 years. Analyses so far have demonstrated a potential for such a transition through energy savings, district heating (DH) and the use of locally available biomass, wind power and low......) and compression heat pumps (HP) for the supply of DH impact the integration of wind power. Hourly scenario-analyses made using the EnergyPLAN model reveal a boiler production and electricity excess which is higher with AHPs than with HPs whereas condensing mode power generation is increased by the application...

  9. Research of the heat exchanging processes running in the heating and hot water supply loops of the coil heat exchangers

    Directory of Open Access Journals (Sweden)

    Ірина Геннадіївна Шитікова

    2016-11-01

    Full Text Available The fuel-energy complex research has made it possible to disclose a huge power-saving potential in the municipal heat-and-power engineering. Power-and-resource-saving units and systems are becoming extremely urgent because of the power engineering crisis expansion. The self-adjusting heat supply system from the individual heating points with the heat-accumulating units and coil heat exchangers for independent heating and water supply systems has been examined. Coil heat exchangers are used in municipal heating for heat transfer (e.g. geothermal waters for the independent mains of the heating and hot water supply systems. The heat engineering calculation of the heating and accumulating unit with the coil heat exchanger for independent heat supply systems from individual heater was performed and experimental data were received at the experimental industrial unit under the laboratory conditions. The peculiarities of the flows in the intertubular space, their influence on the heat exchange and temperatures of the first and intermediate mains have been shown. It is important to know the processes running inside the apparatus to be able to improve the technical characteristics of the three-loop coil heat exchanger. The task solution will make it possible to save the materials consumption for the three-loop coil heat exchangers in the future

  10. Regionalized LCA-based optimization of building energy supply: method and case study for a Swiss municipality.

    Science.gov (United States)

    Saner, Dominik; Vadenbo, Carl; Steubing, Bernhard; Hellweg, Stefanie

    2014-07-01

    This paper presents a regionalized LCA-based multiobjective optimization model of building energy demand and supply for the case of a Swiss municipality for the minimization of greenhouse gas emissions and particulate matter formation. The results show that the environmental improvement potential is very large: in the optimal case, greenhouse gas emissions from energy supply could be reduced by more than 75% and particulate emissions by over 50% in the municipality. This scenario supposes a drastic shift of heat supply systems from a fossil fuel dominated portfolio to a portfolio consisting of mainly heat pump and woodchip incineration systems. In addition to a change in heat supply technologies, roofs, windows and walls would need to be refurbished in more than 65% of the municipality's buildings. The full potential of the environmental impact reductions will hardly be achieved in reality, particularly in the short term, for example, because of financial constraints and social acceptance, which were not taken into account in this study. Nevertheless, the results of the optimization model can help policy makers to identify the most effective measures for improvement at the decision making level, for example, at the building level for refurbishment and selection of heating systems or at the municipal level for designing district heating networks. Therefore, this work represents a starting point for designing effective incentives to reduce the environmental impact of buildings. While the results of the optimization model are specific to the municipality studied, the model could readily be adapted to other regions.

  11. Future heat supply of our cities. Heating by waste heat

    Energy Technology Data Exchange (ETDEWEB)

    Brachetti, H E [Stadtwerke Hannover A.G. (Germany, F.R.); Technische Univ. Hannover (Germany, F.R.))

    1976-08-01

    The energy-price crisis resulted in structural changes of the complete energy supply and reactivated the question of energy management with respect to the optimum solution of meeting the energy requirements for space heating. Condensation power plants are increasingly replaced by thermal stations, the waste heat of which is used as so-called district heat. Thermal power stations must be situated close to urban areas. The problem of emission of harmful materials can partly be overcome by high-level emission. The main subject of the article, however, is the problem of conducting and distributing the heat. The building costs of heat pipeline systems and the requirements to be met by heat pipelines such as strength, heat insulation and protection against humidity and ground water are investigated.

  12. Strategi for CO2-reduktion i den individuelle varmeforsyning: Strategy for CO2 reduction in the individual heat supply

    OpenAIRE

    Schjerling, Tina Gliese

    2008-01-01

    The project is made in cooperation with Lolland municipality, which has set a series of ambitious goals in relation to reducing the CO2 emissions in the municipality. One of the challenges faced by the municipality in this connection is to achieve a cleaner heat supply. The collective heat supply is almost 100% CO2-neutral, as the district heating plants primarily use CO2-neutral fuel. However, there are a great number of households outside the collective heat supply, which are heated by mean...

  13. Geothermal heat-pump systems of heat supply

    International Nuclear Information System (INIS)

    Vasil'ev, G.P.

    2004-01-01

    The data on the multilayer operation of the objects, located in the climatic conditions of the central area of Russia and equipped with the geothermal heat-pumping systems of the heat supply are presented. The results of the analytical studies on evaluating the geothermal heat-pumping systems of the heat supply integration efficiency into the structure of the energy supply system, prevailing in the country, are presented [ru

  14. Optimum design of a nuclear heat supply

    International Nuclear Information System (INIS)

    Borel, J.P.

    1984-01-01

    This paper presents an economic analysis for the optimum design of a nuclear heat supply to a given district-heating network. First, a general description of the system is given, which includes a nuclear power plant, a heating power plant and a district-heating network. The heating power plant is fed with steam from the nuclear power plant. It is assumed that the heating network is already in operation and that the nuclear power plant was previously designed to supply electricity. Second, a technical definition of the heat production and transportation installations is given. The optimal power of these installations is examined. The main result is a relationship between the network capacity and the level of the nuclear heat supply as a substitute for oil under the best economic conditions. The analysis also presents information for choosing the best operating mode. Finally, the heating power plant is studied in more detail from the energy, technical and economic aspects. (author)

  15. Thermal Efficiency of Cogeneration Units with Multi-Stage Reheating for Russian Municipal Heating Systems

    Directory of Open Access Journals (Sweden)

    Evgeny Lisin

    2016-04-01

    Full Text Available This paper explores the layout of an optimum process for supplying heat to Russian municipal heating systems operating in a market environment. We analyze and compare the standard cogeneration unit design with two-stage reheating of service water coming from controlled extraction locations and layouts that employ three in-line reheaters with heat the supply controlled by a rotary diaphragm and qualitative/quantitative methods (so-called “uncontrolled extraction”. Cogeneration unit designs are benchmarked in terms of their thermal efficiency expressed as a fuel consumption rate. The specific fuel consumption rate on electricity production is viewed as a key parameter of thermal efficiency.

  16. Process heat supply requirements on HTGRs

    International Nuclear Information System (INIS)

    Schad, M.K.

    1989-01-01

    Since it has been claimed that the MHTGR is competitive with coal in producing electricity, the MHTGR must be competitive in producing process heat. There is a huge process heat market and there are quite a number of processes where the industrial MHTGR = HTRI could supply the necessary process heat and energy. However, to enhance its introduction on the market and to conquer a reasonable share of the market, the HTRI should fulfill the following major requirements: Unlimited constant and flexible heat supply, no secondary heat transport system at higher temperatures and low radioactive contamination level of the primary helium. Unlimited constant and flexible heat supply could be achieved with smaller HTRIs having heat generation capacities below 100 MW-th. The process heat generated by smaller HTRIs need not be more expensive since the installed necessary heat supply redundancy is smaller and the excess power density lower. The process heat at elevated temperatures generated by a HTRI with a secondary heat transfer system is much more expensive due to the additional investment and operating cost as well as the reduced helium temperature span available. For some processes, the HTRI is not able to cover the total process heat requirement while other processes can consume only part of the heat offered. These limitations could be reduced by using higher core outlet and inlet temperatures or both. Due to the considerably lower heat transfer rates and the resulting larger heat transfer areas in process plants, the diffusion of nuclear activity at elevated temperatures may increase so that a more efficient helium cleaning system may be required. (author). 5 figs, 3 tabs

  17. Discussion on Construction Technology of Prestressed Reinforced Concrete Pipeline of Municipal Water Supply and Drainage

    Science.gov (United States)

    Li, Chunyan

    2017-11-01

    Prestressed reinforced concrete pipe has the advantages of good bending resistance, good anti-corrosion, anti-seepage, low price and so on. It is very common in municipal water supply and drainage engineering. This paper mainly explore the analyze the construction technology of the prestressed reinforced concrete pipe in municipal water supply and drainage engineering.

  18. District heating in sequential energy supply

    International Nuclear Information System (INIS)

    Persson, Urban; Werner, Sven

    2012-01-01

    Highlights: ► European excess heat recovery and utilisation by district heat distribution. ► Heat recovery in district heating systems – a structural energy efficiency measure. ► Introduction of new theoretical concepts to express excess heat recovery. ► Fourfold potential for excess heat utilisation in EU27 compared to current levels. ► Large scale excess heat recovery – a collaborative challenge for future Europe. -- Abstract: Increased recovery of excess heat from thermal power generation and industrial processes has great potential to reduce primary energy demands in EU27. In this study, current excess heat utilisation levels by means of district heat distribution are assessed and expressed by concepts such as recovery efficiency, heat recovery rate, and heat utilisation rate. For two chosen excess heat activities, current average EU27 heat recovery levels are compared to currently best Member State practices, whereby future potentials of European excess heat recovery and utilisation are estimated. The principle of sequential energy supply is elaborated to capture the conceptual idea of excess heat recovery in district heating systems as a structural and organisational energy efficiency measure. The general conditions discussed concerning expansion of heat recovery into district heating systems include infrastructure investments in district heating networks, collaboration agreements, maintained value chains, policy support, world market energy prices, allocation of synergy benefits, and local initiatives. The main conclusion from this study is that a future fourfold increase of current EU27 excess heat utilisation by means of district heat distribution to residential and service sectors is conceived as plausible if applying best Member State practice. This estimation is higher than the threefold increase with respect to direct feasible distribution costs estimated by the same authors in a previous study. Hence, no direct barriers appear with

  19. Proposal for a district heat supply system

    International Nuclear Information System (INIS)

    Alefeld, G.

    1976-01-01

    A district heating scheme is proposed which makes it possible to use the waste heat from power stations for the supply of households and industry. The heat is stored by evaporation of ammonia salts or liquids with dissolved salts. Both substances are transported on existing rail- or waterways to heating stations near the consumers, and the heat recovered by reaction of the two components. Then the product of reaction is transported back to the power stations, and reactivated by heat again. Based on a cost estimation, it can be shown that the proposed heat transport with heat trains or ships, at distances up to 100 km, results in heat costs which are to-day already below that of heat from fuel oil. The investment required for the heat transport system is unusually low due to the use of transport ways which already exist. The district heating system is not only favourable in respect of the environment, but actually reduces its present strain, both at the consumer and at the power stations. The technical advantages of the suggested concept, especially the possibility of introducing it in stages, are discussed. The consequences for the national economy regarding the safety of supply and the trade balance, as well as for the public transport undertakings, are obvious, and therefore not included in the paper. (orig.) [de

  20. Cogeneration and District Heating. Best Practices for Municipalities

    International Nuclear Information System (INIS)

    Nuorkivi, A.; Constantinescu, T.

    2005-01-01

    District heating (DH) and cogeneration of heat power (CHP) are well known technologies in the energy business and are often included in municipal policies as well. Some of the major benefits of DH and CHP are less known and the barriers faced by further development of DH and CHP are substantial. The main barriers are institutional. Municipalities can play a powerful role in facilitating local DH and CHP development in order to achieve the economic and environmental benefits of DH and CHP. This report is produced to assist municipalities in promoting efficient and environmental beneficial DH and CHP. The focus of the report is on the economies in transition, where the institutional barriers are acute. The report addresses the issues of organisational framework, price regulation and financing, energy demand, rehabilitation of DH systems and benchmarking of DH and CHP. The municipality may influence the DH development by a number of means. The most important means, discussed in the various chapters of the report, are: (1) City planning impacts on the heat load density. A high density is an important factor for the economics of DH and city planning may promote DH in areas with high density and individual heating modes in the areas with low density; (2) Managing the building stock owned by the municipality to join the DH system and paying for the heating services; (3) Setting strategic goals for the District Heating Enterprise (DHE), which they usually own, regarding the quality and the costs of heating. The DHE shall be given sufficient resources to work towards such goals; (4) Providing guarantees for financing DH rehabilitation and development. The DHE may not have access to commercial credits without municipal guarantees; and, (5) Supporting the DHE management by giving operational independence, supervising the management performance regularly and encouraging the co-operation with other DHEs and equipment manufacturers. Examples provided in the report of

  1. Typhoon and elevated radon level in a municipal water supply

    International Nuclear Information System (INIS)

    Mao, Cheng-Hsin; Weng, Pao-Shan

    2000-01-01

    The Municipal Water Supply at Hsinchu City is a water treatment plant using poly- aluminum chloride (PAC) for coagulation and then followed by precipitation and filtration. Its capacity is 70,000 m 3 /day. The raw water is drawn from the nearby river. Since the subject of interest is the radon level during typhoon season, the sampling period was from March to December 1999. Commercially available electret was used for water samples taken from the five ponds in the plant. This technique relies on the measurement of radon in air above a water sample enclosed in a sealed vessel. The concentration of airbone radon released from water was determined by means of the electret ion chamber. During the first sampling period there came two typhoons. One is called Magie during June 10-17, and the other called Sam during August 20-26. The first typhoon led to the radon level measured from the water samples as high as 705 Bq/m 3 , while the second caused even higher radon level as high as 772 Bq/m 3 . Similar results were obtained for the second sampling period after August till December 1999. For those measured without typhoon influence, the average radon was lower from the coagulation pond yet without coagulation process during March through August 1999. However, water samples taken from the pond after precipitation did not show similar results in radon level. (author)

  2. Supply of Prague with heat from a nuclear heat source

    International Nuclear Information System (INIS)

    Poul, F.

    1976-01-01

    The proposals are discussed of supplying Prague, the Czechoslovak Capital, with nuclear reactor-generated heat energy. The proposals meet the requirements of the general urban plan of development. The first nuclear heating plant is to be sited in the Kojetice locality, in the northern Prague suburb. It will be commissioned by 1984 and 1985. It is estimated that the maximum heat output in form of hot water will be 821 MW. By 1995 the construction of the second nuclear heating plant should be started southeast or east of Prague. The connection of these two nuclear plants to the hot water mains together with other conventional heating plants will secure the heat supply for Prague and its new housing estates and industrial works. (Oy)

  3. The impact of municipal waste combustion in small heat sources

    Science.gov (United States)

    Vantúch, Martin; Kaduchová, Katarína; Lenhard, Richard

    2016-06-01

    At present there is a tendency to make greater use for heating houses for burning solid fuel, such as pieces of wood, coal, coke, local sources of heat to burn natural gas. This tendency is given both the high price of natural gas as well as the availability of cheaper solid fuel. In many cases, in the context saving heating costs, respectively in the context of the disposal of waste is co-incinerated with municipal solid fuels and wastes of different composition. This co entails increased production emissions such as CO (carbon monoxide), NOx (nitrogen oxides), particulate matter (particulate matter), PM10, HCl (hydrogen chloride), PCDD/F (polychlorinated dibenzodioxins and dibenzofurans), PCBs (polychlorinated biphenyls) and others. The experiment was focused on the emission factors from the combustion of fossil fuels in combination with municipal waste in conventional boilers designed to burn solid fuel.

  4. Developing a Procedure for Segmenting Meshed Heat Networks of Heat Supply Systems without Outflows

    Science.gov (United States)

    Tokarev, V. V.

    2018-06-01

    The heat supply systems of cities have, as a rule, a ring structure with the possibility of redistributing the flows. Despite the fact that a ring structure is more reliable than a radial one, the operators of heat networks prefer to use them in normal modes according to the scheme without overflows of the heat carrier between the heat mains. With such a scheme, it is easier to adjust the networks and to detect and locate faults in them. The article proposes a formulation of the heat network segmenting problem. The problem is set in terms of optimization with the heat supply system's excessive hydraulic power used as the optimization criterion. The heat supply system computer model has a hierarchically interconnected multilevel structure. Since iterative calculations are only carried out for the level of trunk heat networks, decomposing the entire system into levels allows the dimensionality of the solved subproblems to be reduced by an order of magnitude. An attempt to solve the problem by fully enumerating possible segmentation versions does not seem to be feasible for systems of really existing sizes. The article suggests a procedure for searching rational segmentation of heat supply networks with limiting the search to versions of dividing the system into segments near the flow convergence nodes with subsequent refining of the solution. The refinement is performed in two stages according to the total excess hydraulic power criterion. At the first stage, the loads are redistributed among the sources. After that, the heat networks are divided into independent fragments, and the possibility of increasing the excess hydraulic power in the obtained fragments is checked by shifting the division places inside a fragment. The proposed procedure has been approbated taking as an example a municipal heat supply system involving six heat mains fed from a common source, 24 loops within the feeding mains plane, and more than 5000 consumers. Application of the proposed

  5. Hybrid district heating system with heat supply from nuclear source

    International Nuclear Information System (INIS)

    Havelka, Z.; Petrovsky, I.

    1987-01-01

    Several designs are described of heat supply from large remote power sources (e.g., WWER-1000 nuclear power plants with a 1000 MW turbine) to localities where mainly steam distribution networks have been built but only some or none networks for hot water distribution. The benefits of the designs stem from the fact that they do not require the conversion of the local steam distribution system to a hot water system. They are based on heat supply from the nuclear power plant to the consumer area in hot water of a temperature of 150 degC to 200 degC. Part of the hot water heat will be used for the production of low-pressure steam which will be compressed using heat pumps (steam compressors) to achieve the desired steam distribution network specifications. Water of lower temperature can be used in the hot water network. The hot water feeder forms an automatic pressure safety barrier in heat supply of heating or technological steam from a nuclear installation. (Z.M.). 5 figs., 9 refs

  6. Optimization of Temperature Schedule Parameters on Heat Supply in Power-and-Heat Supply Systems

    Directory of Open Access Journals (Sweden)

    V. A. Sednin

    2009-01-01

    Full Text Available The paper considers problems concerning optimization of a temperature schedule in the district heating systems with steam-turbine thermal power stations having average initial steam parameters. It has been shown in the paper that upkeeping of an optimum network water temperature permits to increase an energy efficiency of heat supply due to additional systematic saving of fuel. 

  7. An Exploration of Supply Chain Management Practices in the Central District Municipality

    Science.gov (United States)

    Ambe, I. M.

    2009-01-01

    The main objective of the paper is to explore supply chain management practices in the Central District Municipality, North West province of South Africa, using the grounded theory methodology. Supply chain management was introduced in the South African public sector to alleviate deficiencies related to governance, interpretation and…

  8. High resolution heat atlases for demand and supply mapping

    Directory of Open Access Journals (Sweden)

    Bernd Möller

    2014-02-01

    Full Text Available Significant reductions of heat demand, low-carbon and renewable energy sources, and district heating are key elements in 100% renewable energy systems. Appraisal of district heating along with energy efficient buildings and individual heat supply requires a geographical representation of heat demand, energy efficiency and energy supply. The present paper describes a Heat Atlas built around a spatial database using geographical information systems (GIS. The present atlas allows for per-building calculations of potentials and costs of energy savings, connectivity to existing district heat, and current heat supply and demand. For the entire building mass a conclusive link is established between the built environment and its heat supply. The expansion of district heating; the interconnection of distributed district heating systems; or the question whether to invest in ultra-efficient buildings with individual supply, or in collective heating using renewable energy for heating the current building stock, can be based on improved data.

  9. Optimization of heat supply systems employing nuclear power plants

    International Nuclear Information System (INIS)

    Urbanek, J.

    1988-01-01

    Decision making on the further development of heat supply systems requires optimization of the parameters. In particular, meeting the demands of peak load ranges is of importance. The heat supply coefficient α and the annual utilization of peak load equipment τ FS have been chosen as the characteristic quantities to describe them. The heat price at the consumer, C V , offers as the optimization criterion. The transport distance, temperature spread of the heating water, and different curves of annual variation of heat consumption on heat supply coefficient and heat price at the consumer. A comparison between heat supply by nuclear power plants and nuclear heating stations verifies the advantage of combined heat and power generation even with longer heat transport distances as compared with local heat supply by nuclear district heating stations based on the criterion of minimum employment of peak load boilers. (author)

  10. Decentralized Heat Supply – Alternative to Centralized One

    OpenAIRE

    V. I. Nazarov; L. A. Tarasevich; А. L. Burov

    2012-01-01

    The paper presents a concrete example that shows comparative characteristics of decentralized and centralized heat supply. It has been shown in the paper that selection of this or that variant of heat supply significantly depends on losses in heat supply networks.

  11. Decentralized Heat Supply – Alternative to Centralized One

    Directory of Open Access Journals (Sweden)

    V. I. Nazarov

    2012-01-01

    Full Text Available The paper presents a concrete example that shows comparative characteristics of decentralized and centralized heat supply. It has been shown in the paper that selection of this or that variant of heat supply significantly depends on losses in heat supply networks.

  12. Supply of fossil heating and motor fuels

    International Nuclear Information System (INIS)

    Kaegi, W.; Siegrist, S.; Schaefli, M.; Eichenberger, U.

    2003-01-01

    This comprehensive study made for the Swiss Federal Office of Energy (SFOE) within the framework of the Energy Economics Fundamentals research programme examines if it can be guaranteed that Swiss industry can be supplied with fossil fuels for heating and transport purposes over the next few decades. The results of a comprehensive survey of literature on the subject are presented, with a major focus being placed on oil. The study examines both pessimistic and optimistic views and also presents an overview of fossil energy carriers and the possibilities of substituting them. Scenarios and prognoses on the availability of fossil fuels and their reserves for the future are presented. Also, new technologies for exploration and the extraction of fossil fuels are discussed, as are international interdependencies that influence supply. Market and price scenarios are presented that take account of a possible increasing scarcity of fossil fuels. The implications for industry and investment planning are examined

  13. Prevalence of Virulent Escherichia coli Belonging B1 Phylogroup in Municipal Water Supply in Dhaka, Bangladesh

    DEFF Research Database (Denmark)

    Ferdous, Jannataul; Rashid, Ridwan Bin; Tulsiani, Suhella

    isolated from drinking water in Arichpur, a low income area of Dhaka, Bangladesh. The distribution of the phylogroups and virulence genes were investigated in 200 isolates among them 110 isolates were from municipal water supply system and 90 were from household drinking water. Gene profile of virulence.......001. Therefore, it can be inferred municipal water supply was a greater contributor of pathogenic E. coli from the B1 phylogroup. Usually commensals fall in the Phylogroups A and B1. The presence of greater number of virulent B1 phylogroup isolates originating from municipal water supply indicates......Escherichia coli is a commensal organism of the digestive tracts of many vertebrates, including humans. Contamination of drinking water with pathogenic E. coli is a serious public health concern. This study focused on the distribution of phylogenetic groups and virulence gene profile of E. coli...

  14. High resolution heat atlases for demand and supply mapping

    DEFF Research Database (Denmark)

    Möller, Bernd; Nielsen, Steffen

    2014-01-01

    Significant reductions of heat demand, low-carbon and renewable energy sources, and district heating are key elements in 100% renewable energy systems. Appraisal of district heating along with energy efficient buildings and individual heat supply requires a geographical representation of heat...... demand, energy efficiency and energy supply. The present paper describes a Heat Atlas built around a spatial database using geographical information systems (GIS). The present atlas allows for per-building calculations of potentials and costs of energy savings, connectivity to existing district heat......, and current heat supply and demand. For the entire building mass a conclusive link is established between the built environment and its heat supply. The expansion of district heating; the interconnection of distributed district heating systems; or the question whether to invest in ultra-efficient buildings...

  15. Integration of biogas in municipal energy planning and supply

    Energy Technology Data Exchange (ETDEWEB)

    Nedergaard, N; Oertenblad, H [Herning Municipal Utilities, Herning (Denmark)

    1997-08-01

    The first biogas plants in Denmark were based on local initiatives and a great deal of idealism. The break through with technically well functioning plants came at the end of the 80`ies. The plants were based on animal manure, and the development came together with the growing environmental demands and the legislation concerning storage capacity and distribution of the manure. This contributed to an increasing interest in joint biogas plants, mainly from the agricultural sector, but also from the industry. Today Denmark has 19 biogas plants in operation, all based on manure co-digested with wastes from the food industry, and 15 farm-scale plants. Only three of the joint plants are owned by a municipality, one plant in Aarhus and two in Herning. (au)

  16. Optimal usage of low temperature heat sources to supply district heating by heat pumps

    DEFF Research Database (Denmark)

    Pieper, Henrik; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    This paper presents a theoretical study on the optimal usage of different low temperature heat sources to supply district heating by heat pumps. The study is based on data for the Copenhagen region. The heat sources were prioritized based on the coefficient of performance calculated for each hour...... and the covered demand of each heat source as well as required peak unit capacity. The results showed that heat pumps using different heat sources yield better performance than a heat pump based on a single one. The performance was influenced by the composition of the different heat sources. It was found that 78......% groundwater, 22% seawater and 0% air resulted in highest COP of 3.33 for the given heat demand. Furthermore, the implementation of rule based short term storage made peak units redundant. The variation in base load capacity showed that heat pumps utilizing the analyzed heat sources could perform very...

  17. Climate change impacts on municipal, mining, and agricultural water supplies in Chile

    Science.gov (United States)

    Daniel G. Neary; Pablo Garcia-Chevesich

    2008-01-01

    Agricultural and municipal water supply interests in Chile rely heavily on streams which flow from the Andes Mountains. The highly productive Copiapo agricultural region, on the southern edge of the Atacama Desert, is a major supplier of fruit and other crops for the Northern American market during winter. This region relies entirely on snow and icemelt streams to...

  18. Life cycle assessment of a commercial rainwater harvesting system compared with a municipal water supply system

    Science.gov (United States)

    Building upon previously published life cycle assessment (LCA) methodologies, we conducted an LCA of a commercial rainwater harvesting (RWH) system and compared it to a municipal water supply (MWS) system adapted to Washington, D.C. Eleven life cycle impact assessment (LCIA) indi...

  19. Microbiology of aquatic environments: Characterizations of the microbiotas of municipal water supplies, the International Space Station Internal Active Thermal Control System's heat transport fluid, and US Space Shuttle drinking water

    Science.gov (United States)

    Bernardini, James Nicholas, III

    Influenza A viruses were used to verify positive microarray hybridizations by quantitative polymerase chain reaction (PCR), reverse transcriptase PCR, and conventional PCR. Experiments were performed using municipal drinking water, IATCS fluids, and Shuttle drinking water. Thus, this dissertation describes what we believe is the first molecular analysis of the IATCS bacterial ecology and the first use and validation of a microarray-based assay for the detection of viral genetic signatures within drinking waters.

  20. District heating system of Belgrade supplied from the co-generation plant 'Obrenovac' (Yugoslavia)

    International Nuclear Information System (INIS)

    Tomic, P.; Dobric, Z.; Studovic, M.

    2000-01-01

    The paper presents most relevant technical and economic features of the Project called 'System for supplying Belgrade with heat' (SDGB) from the thermal power plant 'Obrenovac', based on domestic coal and reconstruction of condensing power plant for combined generation of electricity and heat for the needs of municipal energy consumption. The system is designed for transport thermal energy, with capacity of 730 MJ/s from the Thermal Power Plant 'Nikola Tesla' / A to the existing heat plant 'Novi Beograd' based on the natural gas. The paper also gives the comparison of most important technical and economic features of 'SDGB' Project with the similar Project of District Heating System for supplying Prague with the thermal energy from Thermal Power Plant Melnik. (Author)

  1. A renewable energy scenario for Aalborg Municipality based on low-temperature geothermal heat, wind power and biomass

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg; Mathiesen, Brian Vad; Möller, Bernd

    2010-01-01

    Aalborg Municipality, Denmark, wishes to investigate the possibilities of becoming independent of fossil fuels. This article describes a scenario for supplying Aalborg Municipality’s energy needs through a combination of low-temperature geothermal heat, wind power and biomass. Of particular focus...... in the scenario is how low-temperature geothermal heat may be utilised in district heating (DH) systems. The analyses show that it is possible to cover Aalborg Municipality’s energy needs through the use of locally available sources in combination with significant electricity savings, heat savings, reductions...... in industrial fuel use and savings and fuel-substitutions in the transport sector. With biomass resources being finite, the two marginal energy resources in Aalborg are geothermal heat and wind power. If geothermal heat is utilised more, wind power may be limited and vice versa. The system still relies...

  2. Distribution of aquifers, liquid-waste impoundments, and municipal water-supply sources, Massachusetts

    Science.gov (United States)

    Delaney, David F.; Maevsky, Anthony

    1980-01-01

    Impoundments of liquid waste are potential sources of ground-water contamination in Massachusetts. The map report, at a scale of 1 inch equals 4 miles, shows the idstribution of aquifers and the locations of municipal water-supply sources and known liquid-waste impoundments. Ground water, an important source of municipal water supply, is produced from shallow sand and gravel aquifers that are generally unconfined, less than 200 feet thick, and yield less than 2,000 gallons per minute to individual wells. These aquifers commonly occupy lowlands and stream valleys and are most extensive in eastern Massachusetts. Surface impoundments of liquid waste are commonly located over these aquifers. These impoundments may leak and allow waste to infiltrate underlying aquifers and alter their water quality. (USGS)

  3. How Danish communal heat planning empowers municipalities and benefits individual consumers

    DEFF Research Database (Denmark)

    Chittum, Anna; Østergaard, Poul Alberg

    2014-01-01

    Danish municipal heat planning empowers municipalities to implement locally appropriate energy solutions that are the best fit for the locality as a whole and the individual consumers served. Supportive policies and actions at the national and local levels have encouraged heat planning that confe...... locations, the practical aspects of power sharing, socio-economic cost–benefit analyses, and communal decision-making may inform approaches to local heat planning around the world....

  4. Local energy supply under national and European law. With special regard to municipal policy opportunities

    International Nuclear Information System (INIS)

    Britz, G.

    1994-01-01

    Conceivably, the erection of a single European energy market for electricity and natural gas as specified in the EC draft guidelines may change the conditions of local energy supply. This thesis therefore investigates which instruments are at the disposal of municipal governments for the realization of energy-political concepts of their own: Rights of way and granting of franchises, establishment of and transfer of tasks to municipal utilities, common carvier duties, and free choice of suppliers by distributors. The handling of franchise payments and treatment of municipal interconnected networks are of considerable importance for the financial situation of communities. The first section deals with the legal issues of local energy supply with regard to national law. The second part deals with the same questions with regard to community law. Furthermore it is considered what would be the consequences of the realization of the two guidelines concerning the single energy market. In the final section the results are compared and the significance of community law for local energy supply is assessed. (orig./HP) [de

  5. Heat supply to low energy dwellings in district heating areas. Analyses of CO{sub 2} emissions and electricity supply security; Varmeforsyning til lavenergiboliger i omraader med fjernvarmekonsesjon. Analyser av CO{sub 2}-utslipp og forsyningssikkerhet for elektrisitet

    Energy Technology Data Exchange (ETDEWEB)

    Thyholt, Marit

    2006-07-01

    Building low energy dwellings in large development projects is a new situation in Norway. The municipalities have to a little extent analyzed the consequences of this new housing standard with respect to the energy supply to such areas, and how this standard may change the plans for new or extended district heat production. In the provision about the mandatory connection to district heating plants, and the appendant provision related to a heating system that can utilize district heat, the district heat supply and the heat demand are not seen in connection. The objective of this dissertation is to provide the municipalities with a basis for decision making in the processing of applications concerning dispensation from the mandatory connection or the heating system requirement for dwellings with low heat demand. This basis for decision making is based on the national aim of reducing carbon dioxide (CO{sub 2}) emissions and of improving the electricity supply security. This summary provides an abstract from the discussion of the legislation as an incentive or barrier for building low energy dwellings. An abstract from a survey among construction firms concerning the motivation for building low energy dwellings is also included. In addition, the summary provides a comprehensive abstract of the results from the CO{sub 2} emission calculations, and the basis for these calculations. Introductorily a brief background of the national focus on energy savings and increased use of hydronic heating, including district heat, is given.

  6. Sustainable heat supply. Status report; Nachhaltige Waermeversorgung. Sachstandsbericht

    Energy Technology Data Exchange (ETDEWEB)

    Strohschein, Jan; Erdmenger, Christoph; Albert, Reihard (and others)

    2007-03-15

    The Federal Environmental Office views sustainable energy supply - of which the heat market is a decisive element - mostly under the aspect of climate protection and emission reduction of climate-relevant gases. If the heat market is to make a contribution here, the heat supply system must be reorganized. This publication of the Federal Environmental Office indicates fields of action in the heat market. The focus is on climate-friendly heat production, e.g. renewable energy sources, cogeneration systems, and higher energy efficiency. The full report can be downloaded from http://www.umweltbundesamt.de/klimaschutz/. (orig./AKB)

  7. Heat pipes as perspective base elements of heat recovery in heat supply and ventilating systems

    Directory of Open Access Journals (Sweden)

    Matveev Andrey

    2017-01-01

    Full Text Available Thermotechnical characteristics of heat pipes are considered as high-efficient heat-transfer devices, which can provide energy-saving technologies for heat supply and ventilating systems and for different branches of industry. Thermotechnical and working (”performance capability” characteristics of heat pipes are investigated. By ”performance capability” of heat pipes and heat-transfer devices on heat pipes we mean the system state, where it can perform set functions and keep parameter values (thermal power, conductivity, thermal resistance, heat-transfer coefficient, temperature level and differential, etc. within the regulations of standardized specifications. The article presents theoretical and experimental methods of «gaslock» length determination on noncondensable gases during long-lasting tests of ammonia heat pipes made of aluminum shape АS – КRА 7.5 – R1 (alloy АD – 31. The paper gives results of research of thermotechnical characteristics of heat pipes in horizontal and vertical states (separate and as a set part while using different systems of thermal insulation. The obtained results of thermotechnical and resource tests show the advantages of ammonia heat pipes as basic elements for heat exchanger design in heating and ventilation systems.

  8. Energy supply and urban planning projects: Analysing tensions around district heating provision in a French eco-district

    International Nuclear Information System (INIS)

    Gabillet, Pauline

    2015-01-01

    Through the analysis of energy supply choices, this article explores the way in which energy priorities and their climate-related features are incorporated into urban public policy. These choices must take account of different factors, as is the case with district heating, which is justified as a vehicle of renewable energy while subject to pressure in eco-districts because its techno-economic balances are destabilised by falls in demand. Our study focuses particularly on the city of Metz (France), which has chosen district heating as the primary source for provision for the municipal area and for its first eco-district. We analyse the tensions within these choices, with particular attention to the way in which they are negotiated inside municipal departments and with the local energy operator. This enables us to explore the tensions in defining the scale that governs decisions and the linkages between energy-related and urban priorities. - Highlights: • Analyses of tensions in the choice of energy supplies for eco-districts. •District heating networks can be vehicles of renewable energy. • District heating networks are threatened by drops in energy consumption. • Energy supply issues oppose urban planning and energy policy in municipal departments. • Technical and financial adjustments can be made by the municipality to justify its energy choices

  9. Heat supply from nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Stach, V [Ustav Jaderneho Vyzkumu CSKAE, Rez (Czechoslovakia)

    1978-05-01

    The current state of world power production and consumption is assessed. Prognoses made for the years 1980 to 2000 show that nuclear energy should replace the major part of fossil fuels not only in the production of power but also in the production of heat. In this respect high-temperature reactors are highly prospective. The question is discussed of the technical and economic parameters of dual-purpose heat and power plants. It is, however, necessary to solve problems arising from the safe siting of nuclear heat and power plants and their environmental impacts. The economic benefits of combined power and heat production by such nuclear plants is evident.

  10. Master plan study - District heating Sillamaee municipality. Estonia. Final report. Appendices for chapter 9

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The appendices to the final report on the master plan study on district heating in the municipality in Estonia, chapter nine, gives data related to general economic assumptions for financial and economic calculations, fuel consumption, financing, prices, fuel consumption. (ARW)

  11. Natural gas and local heat supply. Erdgas und Nahwaerme

    Energy Technology Data Exchange (ETDEWEB)

    Berge, W. (Gasversorgungsgesellschaft Filstal mbH (Germany, F.R.) Stadtwerke Goeppingen (Germany, F.R.))

    Local heat supply consists of a thermal power station of a dual-purpose plant, a heat destribution system and the heating systems of the users. A combination of gas heat-pumps, cogeneration plant and gas turbine operated as basic load aggregates is a precondition for the flexible application of energy-saving though investment-intensive technologies. Several existing plants are described in order to explain the structure and functioning of various types of plants. (BWI).

  12. Internalising external costs of electricity and heat production in a municipal energy system

    International Nuclear Information System (INIS)

    Holmgren, Kristina; Amiri, Shahnaz

    2007-01-01

    Both energy supply and waste treatment give rise to negative effects on the environment, so-called external effects. In this study, monetary values on external costs collected from the EU's ExternE project are used to evaluate inclusion of these costs in comparison with an energy utility perspective including present policy instruments. The studied object is a municipal district heating system with a waste incineration plant as the base supplier of heat. The evaluation concerns fuels used for heat production and total electricity production, for scenarios with external costs included and for a scenario using the present policy instrument. Impacts of assumptions on marginal power producers (coal or natural gas power plants) are investigated, since locally produced electricity is assumed to replace marginal power and thus is credited for the avoided burden. Varying levels of external costs for carbon dioxide emissions are analysed. The method used is an economic optimisation model, MODEST. The conclusion is that present policy instruments are strong incentives for cogeneration, even when external costs are included. Waste is fully utilised in all scenarios. In cases where coal is the marginal power producer, more electricity is produced; when natural gas is the marginal power producer, less is produced. There are several uncertainties in the data for external costs, both methodological and ethical. In the ExternE data, not all environmental impacts are included. For waste incineration, ashes are not included, and another difficulty is how to treat the avoided burden of other waste treatment methods

  13. Projecting demand and supply of forest biomass for heating in Norway

    International Nuclear Information System (INIS)

    Tromborg, Erik; Havskjold, Monica; Lislebo, Ole; Rorstad, Per Kristian

    2011-01-01

    This paper assesses the increase in demand and supply for forest biomass for heating in Norway in 2020. By then there is a political aim to double the national production of bioenergy from the level in 2008. The competitiveness of woody biomass in central and district heating is analyzed in a model selecting the least-cost heating technology and scale in municipalities given a set of constraints and under different fuels price scenarios. The supply of forest biomass from roundwood is estimated based on data of forest inventories combined with elasticities regarding price and standing volumes. The supply of biomass from harvesting residues is estimated in an engineering approach based on data from the national forest inventories and roundwood harvest. The results show how the production of bioenergy is affected by changes in energy prices and support schemes for bioenergy. One conclusion from the analyses is that the government target of 14 TWh more bioenergy by 2020 is not likely to be met by current technologies and policy incentives. The contribution of the analysis is the detailed presentation of the heat market potentials and technology choices combined with supply functions for both roundwood and harvesting residues. - Highlights: → This paper accesses the demand and supply for forest biomass for heating in Norway in 2020. → Market share for wood in central and new district heating is analyzed in a cost-minimizing model. → The supply of forest biomass includes wood chips from import, roundwood and harvesting residues. → The production of bioenergy is affected by changes in energy prices and support schemes. → The government target for bioenergy is not met by current technologies and policy incentives.

  14. Application of SAW method for multiple-criteria comparative analysis of the reliability of heat supply organizations

    Science.gov (United States)

    Akhmetova, I. G.; Chichirova, N. D.

    2016-12-01

    Heat supply is the most energy-consuming sector of the economy. Approximately 30% of all used primary fuel-and-energy resources is spent on municipal heat-supply needs. One of the key indicators of activity of heat-supply organizations is the reliability of an energy facility. The reliability index of a heat supply organization is of interest to potential investors for assessing risks when investing in projects. The reliability indices established by the federal legislation are actually reduced to a single numerical factor, which depends on the number of heat-supply outages in connection with disturbances in operation of heat networks and the volume of their resource recovery in the calculation year. This factor is rather subjective and may change in a wide range during several years. A technique is proposed for evaluating the reliability of heat-supply organizations with the use of the simple additive weighting (SAW) method. The technique for integrated-index determination satisfies the following conditions: the reliability level of the evaluated heat-supply system is represented maximum fully and objectively; the information used for the reliability-index evaluation is easily available (is located on the Internet in accordance with demands of data-disclosure standards). For reliability estimation of heat-supply organizations, the following indicators were selected: the wear of equipment of thermal energy sources, the wear of heat networks, the number of outages of supply of thermal energy (heat carrier due to technological disturbances on heat networks per 1 km of heat networks), the number of outages of supply of thermal energy (heat carrier due to technologic disturbances on thermal energy sources per 1 Gcal/h of installed power), the share of expenditures in the cost of thermal energy aimed at recovery of the resource (renewal of fixed assets), coefficient of renewal of fixed assets, and a coefficient of fixed asset retirement. A versatile program is developed

  15. SELECTION OF HEAT SUPPLY SOURCE FOR MOBILE BUILDING STRUCTURE

    OpenAIRE

    T. I. Dolgikh; S. V. Morozov; Yu. P. Orlov; A. B. Reis; A. Yu Yakovlev

    2014-01-01

    The paper proposes a vortex heat generator with energy transformation of the highest  state  of matter motion  into  the  lowest  one  as  a  heat  supply  source  for a mobile object. Energy transformation coefficient indices close or equal to 1 have been obtained as a result of experiments on efficiency of the vortex heat generator. Such results can be explained with the help of the 2nd Bohr quantum postulate. Standard series of certified VTG heat generators has been proposed for heat suppl...

  16. Small-scale hybrid plant integrated with municipal energy supply system

    International Nuclear Information System (INIS)

    Bakken, B.H.; Fossum, M.; Belsnes, M.M.

    2001-01-01

    This paper describes a research program started in 2001 to optimize environmental impact and cost of a small-scale hybrid plant based on candidate resources, transportation technologies and conversion efficiency, including integration with existing energy distribution systems. Special attention is given to a novel hybrid energy concept fuelled by municipal solid waste. The commercial interest for the model is expected to be more pronounced in remote communities and villages, including communities subject to growing prosperity. To enable optimization of complex energy distribution systems with multiple energy sources and carriers a flexible and robust methodology must be developed. This will enable energy companies and consultants to carry out comprehensive feasibility studies prior to investment, including technological, economic and environmental aspects. Governmental and municipal bodies will be able to pursue scenario studies involving energy systems and their impact on the environment, and measure the consequences of possible regulation regimes on environmental questions. This paper describes the hybrid concept for conversion of municipal solid waste in terms of energy supply, as well as the methodology for optimizing such integrated energy systems. (author)

  17. Dream aim reached: 1300 operational district heating supply connections

    Energy Technology Data Exchange (ETDEWEB)

    Handl, K H

    1988-11-01

    Only four years after the beginning of operation of the first consumer station at Klingnau on October 19, 1984, the Regional District Heating Supply in the Lower Aare Valley (Refuna) can already show 1295 operational district heating connections. There are almost 300 more than one year ago and about 20% more than originally foreseen during this short construction time. As in recent years, the number of consumers has significantly increased during a 'connection boom' in the first autumn weeks. The total heat supply power amounts to 51500 kilowatts. This is 70% of the power foreseen in the final stage. 3 figs., 1 tab.

  18. Waterborne norovirus outbreak in a municipal drinking-water supply in Sweden.

    Science.gov (United States)

    Riera-Montes, M; Brus Sjölander, K; Allestam, G; Hallin, E; Hedlund, K-O; Löfdahl, M

    2011-12-01

    During Easter 2009, almost 200 people resident in a small Swedish village fell ill with gastrointestinal symptoms. We conducted a retrospective cohort study and a molecular investigation in order to identify the source of the outbreak. Residents living in households connected to the public water network were at an increased risk of developing disease (relative risk 4·80, 95% confidence interval 1·68-13·73) compared to those with no connection to the public network. Norovirus genotype GI.3 was identified in stool samples from six patients and in a sample from the public water network. Contamination of one of the wells supplying the public water network was thought to be the source of the outbreak. This is a description of a norovirus outbreak linked to a municipal drinking-water supply in Sweden. Information from epidemiological and molecular investigations is of utmost importance to guide outbreak control measures and to prevent future outbreaks.

  19. Loop heat pipes - highly efficient heat-transfer devices for systems of sun heat supply

    Energy Technology Data Exchange (ETDEWEB)

    Maydanik, Yu. [Ural Branch of the Russian Academy of Sciences, Ekaterinburg (Russian Federation). Inst. of Thermophysics

    2004-07-01

    Loop heat pipes (LHPs) are hermetic heat-transfer devices operating on a closed evaporation-condensation cycle with the use of capillary pressure for pumping the working fluid [1]. In accordance with this, they possess all the main advantages of conventional heat pipes, but, as distinct from the latter, have a considerably higher heat-transfer capacity, especially when operating in the ''antigravity'' regime, when heat is transferred from above downwards. Besides, LHPs possess a higher functional versatility, are adaptable to different operating conditions and provide great scope for various design embodiments. This is achieved at the expense of both the original design of the device and the properties of the wick - a special capillary structure used for the creation of capillary pressure. The LHP schematic diagram is given in Fig. 1. The device contains an evaporator and a condenser - heat exchanger connected by means of smooth-walled pipe-lines with a relatively small diameter intended for separate motion of vapor and liquid. At present loop heat pipes are most extensively employed in thermoregulation systems of spacecrafts. Miniature LHPs are used for cooling electronics and computers. At the same time there exists a considerable potential of using these devices for the recovery of low-grade (waste) heat from different sources, and also in systems of sun heat supply. In the latter case LHPs may serve as an efficient heat-transfer link between a sun collector and a heat accumulator, which has a low thermal resistance and does not consume any additional energy for pumping the working fluid between them. (orig.)

  20. Prospects of heat supply from Temelin nuclear power plant

    International Nuclear Information System (INIS)

    Kuba, V.

    1987-01-01

    The possibilities are discussed of using the Temelin nuclear power plant for heat supply to a number of localities in the South Bohemian Region, to a distance of up to 34 km. Direct supply of steam and of 150/70 degC or 180/65 degC hot water is envisaged. An alternative solution has also been proposed allowing to supply steam and hot water simultaneously from 180 degC hot water with quantitative regulation. The hot water is made to expand at a pressure of 0.3 to 0.5 MPa and the low-pressure steam is compressed to a pressure of 0.9 to 1.3 MPa. This steam will be supplied to the existing heating system. The possibility was also studied of supplying Prague with heat and 180/65 degC hot water of a thermal output of up to 1,700 MW using a two-pipe heat supply line of 105 to 125 km in length. (B.S.). 2 figs

  1. SELECTION OF HEAT SUPPLY SOURCE FOR MOBILE BUILDING STRUCTURE

    Directory of Open Access Journals (Sweden)

    T. I. Dolgikh

    2014-01-01

    Full Text Available The paper proposes a vortex heat generator with energy transformation of the highest  state  of matter motion  into  the  lowest  one  as  a  heat  supply  source  for a mobile object. Energy transformation coefficient indices close or equal to 1 have been obtained as a result of experiments on efficiency of the vortex heat generator. Such results can be explained with the help of the 2nd Bohr quantum postulate. Standard series of certified VTG heat generators has been proposed for heat supply of the mobile object (field hospital.

  2. Municipal Development of Anaerobic Digestion/ Combined Heat and Power in Massachusetts

    Science.gov (United States)

    Pike, Brenda

    With a commercial food waste ban going into effect in Massachusetts in October 2014, businesses, institutions, and municipalities are considering alternatives to landfills and incinerators for organic waste. Anaerobic digestion is one such alternative. Similar to composting, but in an environment devoid of oxygen, anaerobic digestion produces byproducts such as methane (which can be burned for heat or electricity) and liquid or solid digestate (which can be used as fertilizer, cattle bedding, and more). Thus, disposal of food waste and other organic materials can become a source of revenue rather than just an expense. Municipalities interested in developing anaerobic digestion/combined heat and power (AD/CHP) facilities have the benefit of desirable options for sites, such as landfill gas facilities and wastewater treatment plants, and potential feedstocks in source-separated residential or municipal food waste or wastewater. This thesis examines the opportunities and challenges for municipal development of AD/CHP facilities in Massachusetts.

  3. Cold local heating. Agrothermal heat supply of an ecovillage; Kalt Nahwaerme. Agrothermische Waermeversorgung einer Plusenergiesiedlung

    Energy Technology Data Exchange (ETDEWEB)

    Pietruschka, Dirk [Hochschule fuer Technik Stuttgart (Germany). Forschungszentrum fuer Nachhaltige Energietechnik; Kluge, Juergen [Doppelacker GmbH, Petershagen-Eggersdorf (Germany)

    2013-03-01

    An ecovillage with highly efficient residential buildings is arisen in the Swabian community Wuestenrot. The power generation in these residential buildings by means of photovoltaic power plants is greater than the energy consumption. Decentralized heat plants supply thermal energy for the space heating and industrial waste. Central agrothermal collectors provide the necessary low-temperature heat for the effective operation of heat pumps over a so-called cold heat grid.

  4. How Danish communal heat planning empowers municipalities and benefits individual consumers

    International Nuclear Information System (INIS)

    Chittum, Anna; Østergaard, Poul Alberg

    2014-01-01

    Danish municipal heat planning empowers municipalities to implement locally appropriate energy solutions that are the best fit for the locality as a whole and the individual consumers served. Supportive policies and actions at the national and local levels have encouraged heat planning that confers significant autonomy to local governments. By examining how power is distributed and shared by different levels of governments in the planning process, this paper investigates how comprehensive energy planning in Denmark has supported the development of highly cost-effective district heating systems. Lessons from the Danish approach to heat planning are considered for their relevance to the United States, where significant technical district heating potential exists, yet remains well outside the typical energy policy discussions. While the specific Danish political context may not be transferable to other locations, the practical aspects of power sharing, socio-economic cost–benefit analyses, and communal decision-making may inform approaches to local heat planning around the world. - Highlights: • Danish district heating has cost-effectively reduced the country's emissions. • Danish heat planning has been critical to the district heating sector's success. • Danish heat planning confers substantial power to municipalities. • Empowering cities offers significant benefits to cities and consumers. • Danish planning practices can be implemented today in the U.S. and other locations

  5. The economics of supplying the supplementary heat in a closed loop water source heat pump system

    International Nuclear Information System (INIS)

    Johnson, R.P.; Bartkus, V.E.; Singh, J.B.

    1993-01-01

    The paper describes the details of a research and demonstration project that will be completed in August 1992 at a healthcare facility in northeastern Pennsylvania. The purpose of the project is to compare the economics of several methods of supplying the supplementary heating in a facility served by a closed loop water source heat pump system. The systems being tested include a storage hot water tank with electric resistance heaters and three air source heat pumps that have the ability to supply the same heat during on-peak hours as well as off-peak hours. The paper compares the projected operating costs of the following: (1) Gas boiler supplying the supplementary heat. (2) Stored hot water supplying the supplementary heat which is generated and stored during off-peak hours using resistance heat on PP ampersand L's offpeak rate. (3) Stored hot water supplying the supplementary heat generated during off-peak hours using the air source heat pumps on PP ampersand L's off-peak rate. (4) Hot water generated by the air source heat pumps supplying the supplementary loop heating on PP ampersand L's general service and time-of-day electric rates. It is generally known in the HVAC industry that a closed loop water source heat pump system can provide one of the most efficient means of space conditioning to a building with high internal gains by transferring the excess heat available in one part of the building to another part of the building where it may be needed for heating. The following flow diagram depicts the relationship of the air source heat pumps with the storage tanks and the building closed water loop

  6. Municipal water-based heat pump heating and/or cooling systems: Findings and recommendations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bloomquist, R.G. [Washington, State Univ., Pullman, WA (United States); Wegman, S. [South Dakota Utilities Commission (United States)

    1998-04-01

    The purpose of the present work was to determine if existing heat pump systems based on municipal water systems meet existing water quality standards, to analyze water that has passed through a heat pump or heat exchanger to determine if corrosion products can be detected, to determine residual chlorine levels in municipal waters on the inlet as well as the outlet side of such installations, to analyses for bacterial contaminants and/or regrowth due to the presence of a heat pump or heat exchanger, to develop and suggest criteria for system design and construction, to provide recommendations and specifications for material and fluid selection, and to develop model rules and regulations for the installation, operation, and monitoring of new and existing systems. In addition, the Washington State University (WSU) has evaluated availability of computer models that would allow for water system mapping, water quality modeling and system operation.

  7. Integration of space heating and hot water supply in low temperature district heating

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Ommen, Torben Schmidt; Markussen, Michael

    2016-01-01

    District heating may supply many consumers efficiently, but the heat loss from the pipes to the ground is a challenge. The heat loss may be lowered by decreasing the network temperatures for which reason low temperature networks are proposed for future district heating. The heating demand...... of the consumers involves both domestic hot water and space heating. Space heating may be provided at low temperature in low energy buildings. Domestic hot water, however, needs sufficient temperatures to avoid growth of legionella. If the network temperature is below the demand temperature, supplementary heating...... is required by the consumer. We study conventional district heating at different temperatures and compare the energy and exergetic efficiency and annual heating cost to solutions that utilize electricity for supplementary heating of domestic hot water in low temperature district heating. This includes direct...

  8. Prospects for development of heat supply systems in high-rise districts

    Science.gov (United States)

    Zhila, Viktor; Solovyeva, Elena

    2018-03-01

    The article analyzes the main advantages and disadvantages of centralized and decentralized heat supply systems in high-rise districts. The main schemes of centralized heat supply systems are considered. They include centralized heat supply from boiler houses, centralized heat supply from autonomous heat sources, heat supply from roof boiler houses and door-to-door heating supply. For each of these variant, the gas distribution systems are considered and analyzed. These systems vary depending on the heat source location. For each of these systems, technical and economic indicators are taken into account, the analysis of which allows choosing the best option for districts where high-rise buildings predominate.

  9. Report of testing and sampling of municipal supply well PM-4

    International Nuclear Information System (INIS)

    Koch, Richard J.; Longmire, Patrick; Rogers, David B.; Mullen, Ken

    1999-01-01

    During drilling of regional aquifer characterization borehole R-25, located in the western part of Los Alamos National Laboratory (LANL) at Technical Area (TA) 16, groundwater samples were collected from perched zones of saturation and the regional aquifer that contained elevated levels of high explosive (HE) compounds. One of the nearest Los Alamos County municipal supply wells potentially located down gradient from borehole R-25 is PM-4, located on Mesita del Buey at the west end of TA-54. During the winter of 1998 and 1999 the pump in PM-4 had been removed from the well for scheduled maintenance by the Los Alamos County Public Utilities Department (PUD). Because the pump was removed from PM-4, the opportunity existed to enter the well to (1) perform tests to determine where within the regional aquifer groundwater entered the well and (2) collect groundwater samples from the producing zones for analyses to determine if HE contaminants were present in discrete zones within the regional aquifer. The report of the activities that were performed during March 1999 for the testing and sampling of municipal supply well PM-4 is provided. The report provides a description of the field activities associated with the two phases of the project, including (1) the results of the static and dynamic spinner log surveys, and (2) a description of the sampling activities and the field-measured groundwater quality parameters that were obtained during sampling activities. This report also provides the analytical results of the groundwater samples and a brief discussion of the results of the project

  10. Some features of an economical central heating water supply

    International Nuclear Information System (INIS)

    Glaeser, G.

    1990-01-01

    This paper is concerned with the necessary savings of energy and fuel as well as reduction of pollutant emission in the field of central district heat supply. Results of studies on solving these problems are presented. To provide thermal power based on heating water essential features of the district heating system in the GDR are outlined and advantages, resources and limits of specific solutions quantified. Finally, selected systems are evaluated as to energy and cost expenses, and some conclusions are drawn for future concepts. (author)

  11. An Analysis of Total Phosphorus Dispersion in Lake Used As a Municipal Water Supply.

    Science.gov (United States)

    Lima, Rômulo C; Mesquita, André L A; Blanco, Claudio J C; Santos, Maria de Lourdes S; Secretan, Yves

    2015-09-01

    In Belém city is located the potable water supply system of its metropolitan area, which includes, in addition to this city, four more municipalities. In this water supply complex is the Água Preta lake, which serves as a reservoir for the water pumped from the Guamá river. Due to the great importance of this lake for this system, several works have been devoted to its study, from the monitoring of the quality of its waters to its hydrodynamic modeling. This paper presents the results obtained by computer simulation of the phosphorus dispersion within this reservoir by the numerical solution of two-dimensional equation of advection-diffusion-reaction by the method θ/SUPG. Comparing these results with data concentration of total phosphorus collected from November 2008 to October 2009 and from satellite photos show that the biggest polluters of the water of this lake are the domestic sewage dumps from the population living in its vicinity. The results obtained indicate the need for more information for more precise quantitative analysis. However, they show that the phosphorus brought by the Guamá river water is consumed in an area adjacent to the canal that carries this water into the lake. Phosphorus deposits in the lake bottom should be monitored to verify their behavior, thus preventing the quality of water maintained therein.

  12. Renewable-based heat supply of multi-apartment buildings with varied heat demands

    International Nuclear Information System (INIS)

    Truong, Nguyen Le; Dodoo, Ambrose; Gustavsson, Leif

    2015-01-01

    This study investigates the cost and primary energy use to heat an existing multi-apartment building in Sweden, before and after deep energy efficiency renovation, with different types of renewable-based systems. District heating systems of different scales as well as local heat production based on bioelectric boilers, ground-source bioelectric heat pumps and wood pellet boilers with or without solar heating are considered. The annual energy demand of the building, calculated hour by hour, with and without energy efficiency improvements, are matched against the renewable-based heat supply options by techno-economic modeling to minimize cost for each considered heat supply option. The results show that the availability of heating technologies at the building site and the scale of the building's heat demand influence the cost and the primary energy efficiency of the heating options. District heat from large-scale systems is cost efficient for the building without energy-efficiency improvement, whereas electric heat pumps and wood pellet boilers are more cost efficient when implementing energy-efficiency improvement. However, the cost difference is small between these alternatives and sensitive to the size of building. Large-scale district heating with cogeneration of power is most primary energy efficient while heat pumps and medium-scale district heating are nearly as efficient. - Highlights: • Heating technologies influence costs and primary energy use of a building. • Large-scale district heating with cogeneration of power is primary energy efficient. • Large-scale district heating is cost efficient for buildings with large heat demand. • Heat pumps and pellet boilers are cost competitive in energy-efficient buildings.

  13. Use of aqua ammonia solution for long distant heat supply from NPP

    International Nuclear Information System (INIS)

    Stolyarevskij, A.Ya.; Fedotov, I.L.; Verkhivker, G.P.

    1989-01-01

    Feasibility study of aqueous-ammonia heat supply systems is presented in brief. Temperature NPP heat is the energy source. It is shown that application of such systems, using industrial waste heat, is more expedient, than application of traditional two-tube heat supply system. Heat supply system without use of waste heat of a consumer is competitive if distances from a consumer exceed 60 km. Heat transfer coefficient of such systems can achieve 90-92%

  14. The Energy, Greenhouse Gas Emissions, and Cost Implications of Municipal Water Supply & Wastewater Treatment

    Science.gov (United States)

    Rodriguez-Winter, Thelma

    All man-made structures and materials have a design life. Across the United States there is a common theme for our water and wastewater treatment facilities and infrastructure. The design life of many of our mid 20 th century water and wastewater infrastructures in the United States have reached or are reaching life expectancy limits (ASCE, 2010). To compound the financial crisis of keeping up with the degradation, meeting and exceeding quality standards has never been more important in order to protect local fresh water supplies. This thesis analyzes the energy consumption of a municipal water and wastewater treatment system from a Lake Erie intake through potable treatment and back through wastewater treatment then discharge. The system boundary for this thesis includes onsite energy consumed by the treatment system and distribution/reclamation system as well as the energy consumed by the manufacturing of treatment chemicals applied during the study periods. By analyzing energy consumption, subsequent implications from greenhouse gas emissions and financial expenditures were quantified. Through the segregation of treatment and distribution processes from non-process energy consumption, such as heating, lighting, and air handling, this study identified that the potable water treatment system consumed an annual average of 2.42E+08 kBtu, spent 5,812,144 for treatment and distribution, and emitted 28,793 metric tons of CO2 equivalent emissions. Likewise, the wastewater treatment system consumed an annual average of 2.45E+08 kBtu, spent 3,331,961 for reclamation and treatment, and emitted 43,780 metric tons of CO2 equivalent emissions. The area with the highest energy usage, financial expenditure, and greenhouse gas emissions for the potable treatment facility and distribution system was from the manufacturing of the treatment chemicals, 1.10E+08 kBtu, 3.7 million, and 17,844 metric tons of CO2 equivalent, respectively. Of the onsite energy (1.4E-03 kWh per gallon

  15. External costs and taxes in heat supply systems

    International Nuclear Information System (INIS)

    Karlsson, Aasa; Gustavsson, Leif

    2003-01-01

    A systems approach was used to compare different heating systems from a consumer perspective. The whole energy system was considered from natural resources to the required energy services. District heating, electric heat pumps, electric boilers, natural-gas-, oil- or pellet-fired local boilers were considered when supplying heat to a detached house. The district heat production included wood-chip-fired and natural-gas-fired cogeneration plants. Electricity other than cogenerated electricity was produced in wood-chip- and natural-gas-fired stand-alone power plants. The analysis includes four tax scenarios, as well as the external cost of environmental and health damage arising from energy conversion emission based on the ExternE study of the European Commission. The most cost-efficient systems were the natural-gas and oil boiler systems, followed by the heat pump and district heating systems, when the external cost and taxes were excluded. When including the external costs of CO 2 emission, the wood-fuel-based systems were much more cost efficient than the fossil-fuel-based systems, also when CO 2 capture and storage were applied. The external costs are, however, highly uncertain. Taxes steer towards lowering energy use and lowering CO 2 emission if they are levied solely on all the fossil-fuel-related emission and fuel use in the systems. If consumer electricity and heat taxes are used, the taxes have an impact on the total cost, regardless of the fuel used, thereby benefiting fuel-based local heating systems. The heat pump systems were the least affected by taxes, due to their high energy efficiency. The electric boiler systems were the least cost-efficient systems, also when the external cost and taxes were included

  16. Nitrogen Gas Heating and Supply System for SST-1 Tokamak

    International Nuclear Information System (INIS)

    Khan, Ziauddin; Pathan, Firozkhan; Paravastu, Yuvakiran; George, Siju; Ramesh, Gattu; Bindu, Hima; Raval, Dilip C.; Thankey, Prashant; Dhanani, Kalpesh; Pradhan, Subrata

    2013-01-01

    Steady State Tokamak (SST-1) vacuum vessel baking as well as baking of the first wall components of SST-1 are essential to plasma physics experiments. Under a refurbishment spectrum of SST-1, the nitrogen gas heating and supply system has been fully refurbished. The SST-1 vacuum vessel consists of ultra-high vacuum (UHV) compatible eight modules and eight sectors. Rectangular baking channels are embedded on each of them. Similarly, the SST-1 plasma facing components (PFC) are comprised of modular graphite diverters and movable graphite based limiters. The nitrogen gas heating and supply system would bake the plasma facing components at 350°C and the SST-1 vacuum vessel at 150°C over an extended duration so as to remove water vapour and other absorbed gases. An efficient PLC based baking facility has been developed and implemented for monitoring and control purposes. This paper presents functional and operational aspects of a SST-1 nitrogen gas heating and supply system. Some of the experimental results obtained during the baking of SST-1 vacuum modules and sectors are also presented here. (fusion engineering)

  17. Nitrate distribution and potential attenuation mechanisms of a municipal water supply bedrock aquifer

    International Nuclear Information System (INIS)

    Opazo, Tomás; Aravena, Ramón; Parker, Beth

    2016-01-01

    The Silurian bedrock aquifer constitutes a major aquifer system for groundwater supply across the Ontario province in Canada. The application of natural and industrial fertilizers near urban centers has led to groundwater NO_3"−-N concentrations that sometimes have exceeded the drinking water limit, posing a threat to the usage of groundwater for the human consumption. Therefore, there is a growing interest and concern about how nitrate is being leached, transported and potentially attenuated in bedrock aquifers. This study assesses the local distribution of groundwater NO_3"− in the up-gradient area of two historically impacted municipal wells, called Carter Wells, in the City of Guelph, Canada, in order to evaluate the potential nitrate attenuation mechanisms, using both groundwater geochemical and isotopic analysis ("3H, δ"1"5N-NO_3, δ"1"8O-NO_3, δ"1"8O-SO_4, δ"3"4S-SO_4) and a detailed vertical hydrogeological and geochemical bedrock characterization. The results indicate that probably the main source of nitrate to the Carter Wells is the up-gradient Arkell Research Station (ARS), an agricultural research facility where manure has been historically applied. The overburden and bedrock groundwater with high NO_3 concentrations at the ARS exhibits a manure-related δ"1"5N and δ"1"8O signature, isotopically similar to the high nitrate in the down-gradient groundwater from domestic wells and from the Carter Wells. The nitrate spatial distribution appears to be influenced and controlled by the geology, in which more permeable rock is found in the Guelph Formation which in turn is related to most of the high NO_3"− groundwater. The presence of an underlying low permeability Eramosa Formation favors the development of oxygen-depleted conditions, a key factor for the occurrence of denitrification. Groundwater with low NO_3"−-N concentrations associated with more oxygen-limited conditions and coincident with high SO_4"2"− concentrations are related to more

  18. Heating and Domestic Hot Water Systems in Buildings Supplied by Low-Temperature District Heating

    DEFF Research Database (Denmark)

    Brand, Marek

    solutions simply redirect the bypassed water back to the DH network without additional cooling, but bypassed water can instead be redirected to floor heating in the bathroom to be further cooled and thus reduce heat loss from the DH network while improving comfort for occupants and still ensure fast DHW...... increased risk of Legionella if the DH substation and DHW system are designed for the low-temperature supply conditions. To ensure the fast provision of DHW during non-heating periods, the supply service pipe should be kept warm, preferably with the bypass solution redirecting the bypass flow to bathroom...... temperature. To accord with the literature, the modelling of internal heat gains reflected the improved efficiency of equipment by reduction of value from 5W/m2 to 4.2W/m2, also modelled as intermittent heat gains based on a realistic week schedule. Furthermore, the indoor set-point temperature was increased...

  19. Lead isotopes in tap water: implications for Pb sources within a municipal water supply system

    International Nuclear Information System (INIS)

    Cheng Zhongqi; Foland, Kenneth A.

    2005-01-01

    Residential tap waters were investigated to examine the feasibility of using isotopic ratios to identify dominant sources of water Pb in the Columbus (Ohio, USA) municipal supply system. Overall, both the concentrations, which are generally low (0.1-28 μg/L), and isotopic compositions of tap water Pb show wide variations. This contrasts with the situation for a limited number of available service lines, which exhibit only a limited Pb-isotope variation but contain Pb of two very different types with one significantly more radiogenic than the other. Most tap water samples in contact with Pb service lines have Pb-isotope ratios that are different from the pipe Pb. Furthermore, the Pb isotope compositions of sequentially drawn samples in the same residence generally are similar, but those from separate residences are different, implying dominant Pb sources from domestic plumbing. A separate pilot study at two residences without Pb service lines shows isotopic similarity between water and solders in each house, further suggesting that the major Pb sources are domestic in these cases and dominated by Pb from solder joints. Although complicated by the broad range of overall Pb-isotope variations observed and limited by sample availability, the results suggest that Pb isotopes can be used effectively to constrain the sources of Pb in tap waters, especially for individual houses where multiple source candidates can be identified

  20. Initiative for local district heating. New chances for municipal utilities. Boundary conditions for the heat market; Initiative Nahwaerme. Neue Chancen fuer Stadtwerke. Rahmenbedingungen fuer den Waermemarkt

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Michael [K.Group GmbH, Muenchen (Germany). Bereich Nachhaltige Energieversorgung und Stadtentwicklung

    2009-06-15

    In the regulated market, municipal utilities are forced to find new fields of activity. The heat market offers good chances. For example, local district heating grids can be established, independent power generation can be encouraged, and new services can be offered which may increase customer loyalty. The district heating initiative of the Baden-Wuerttemberg Minister of the Environment was launched early in 2009 with the intention to offer valuable assistance to the municipal utilities. (orig.)

  1. DEVELOPMENT OF TECHNICAL DECISIONS FOR HEAT SUPPLY WITH TUBULAR GAS HEATERS

    Directory of Open Access Journals (Sweden)

    IRODOV V. F.

    2017-05-01

    Full Text Available Annotation. Problems formulation. The problem that is solved is the development of autonomous heat supply systems that reduce the capital costs of construction and increase the efficiency of the use of energy resources. One of the ways to solve this problem is the use of tubular gas heaters. For this, it is necessary to develop new technical solutions for heat supply with tubular gas heaters, as well as scientific and methodological support for the development, construction and operation of heat supply systems with tubular gas heaters. Analysis of recent research. Preliminary studies of infrared tubular gas heaters are considered, which were used to heat industrial enterprises with sufficiently high premises. The task was to extend the principles of heat supply by means of tubular heaters for heating air, water and heating medium in relatively low rooms. Goal and tasks. To lay out the development of technical solutions for heat supply with tubular gas heaters, which increase the efficiency and reliability of heat supply systems and extend the use of tubular gas heaters in heat supply. Results. Technical solutions for heat supply with tubular gas heaters have made it possible to extend their applications for heating air, water and heating medium in relatively low rooms. Scientific novelty. New technical solutions for heat supply with tubular gas heaters increase the efficiency of using fuel and energy resources at low capital costs. Practical significance. Technical solutions for heat supply using tubular heaters have the potential for wide application in the heat supply of industrial, public and residential facilities. Conclusions. For two decades, new technical solutions for heat supply with tubular gas heaters have been developed, which increase the efficiency and reliability of heat supply systems and can be widely used for autonomous heating.

  2. Mathematical model for calculation of the heat-hydraulic modes of heating points of heat-supplying systems

    Science.gov (United States)

    Shalaginova, Z. I.

    2016-03-01

    The mathematical model and calculation method of the thermal-hydraulic modes of heat points, based on the theory of hydraulic circuits, being developed at the Melentiev Energy Systems Institute are presented. The redundant circuit of the heat point was developed, in which all possible connecting circuits (CC) of the heat engineering equipment and the places of possible installation of control valve were inserted. It allows simulating the operating modes both at central heat points (CHP) and individual heat points (IHP). The configuration of the desired circuit is carried out automatically by removing the unnecessary links. The following circuits connecting the heating systems (HS) are considered: the dependent circuit (direct and through mixing elevator) and independent one (through the heater). The following connecting circuits of the load of hot water supply (HWS) were considered: open CC (direct water pumping from pipelines of heat networks) and a closed CC with connecting the HWS heaters on single-level (serial and parallel) and two-level (sequential and combined) circuits. The following connecting circuits of the ventilation systems (VS) were also considered: dependent circuit and independent one through a common heat exchanger with HS load. In the heat points, water temperature regulators for the hot water supply and ventilation and flow regulators for the heating system, as well as to the inlet as a whole, are possible. According to the accepted decomposition, the model of the heat point is an integral part of the overall heat-hydraulic model of the heat-supplying system having intermediate control stages (CHP and IHP), which allows to consider the operating modes of the heat networks of different levels connected with each other through CHP as well as connected through IHP of consumers with various connecting circuits of local systems of heat consumption: heating, ventilation and hot water supply. The model is implemented in the Angara data

  3. Master plan study - District heating Kohtla-Jaerve and Johvi municipalities. Estonia. Final report. Appendices for chapter 9

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The appendices to chapter nine of the final report of the master plan study on district heating in the municipalities of Kohtla-Jarve and Johvi municipalities (Estonia) present extensive data relating to economic, financial and environmental calculations, fuel consumption, energy balance and prices. (ARW)

  4. Municipal management and geo-hydrological aspects of importance in the potable water supply of Lindley

    Directory of Open Access Journals (Sweden)

    Eric Nealer

    2014-07-01

    Full Text Available When the South African Government in 1998 re-demarcated its 283 municipalities so that they completely cover the country in a “wall-to-wall” manner, their main focus was on growing local economies and maintaining the provision of an increased number of diverse and more complex basic municipal services to new geographical areas consisting of millions of citizens who might previously had been neglected. In most of the instances the newly established and merged municipalities were demarcated according to geographical aspects inherited from the previous political dispensation, historical municipal areas and magisterial district farm names. The fact that these municipal government jurisdictions for the purpose of improving co-operative municipal- and integrated water resources management (IWRM, in most instances do not correspond with environmental and physical land features such as the demarcated surface water (rivers drainage regions’ boundaries, could lead to the ineffective, inefficient and non-economic municipal management of water, sanitation and environmental services. The aforementioned is a case with reference to water services management in the Free State Province town of Lindley located in the Vals River catchment and the Nketoana Local Municipality’s area of jurisdiction. An extensive literature review, the use and study of geographic tools such as maps, ortho- photos and information data bases, as well as two field visits to the area, enabled the researchers to identify the essential geographical, geo-hydrological and municipal management aspects of importance for the potable water service providers and managers in the Lindley municipal area. The researchers argue that effective trans-boundary municipal management through simunye-type co-operative governance and IWRM must be facilitated in the Vals River surface water catchment between the respective local- and district municipalities for the benefit of the Lindley, Arlington

  5. Dual-purpose LWR supplying heat for desalination

    International Nuclear Information System (INIS)

    Waplington, G.; Fitcher, H.

    1977-01-01

    A number of desalination processes are at present in various stages of development but distillation is the only serious choice for a large-scale project. The distillation process temperature requirement is low compared with the temperature of steam normally delivered to the turbine in a power generation plant. This gives the possibility for combining the functions of electricity generation with water distillation. The brine heater of the multi-stage flash distillation plant can be supplied with steam after partial expansion through a turbine. Such an arrangement allows the use of a standard nuclear steam supply system and makes fuller use of the energy output than would either single purpose role. The LWR represents a safe, reliable and economic system, and is easily able to provide heat of a quality adequate for the desalination process. (M.S.)

  6. Ground Source Heat Supply in Moscow Oblast: Temperature Potential and Sustainable Depth of Heat Wells

    Science.gov (United States)

    Vasil'ev, G. P.; Gornov, V. F.; Dmitriev, A. N.; Kolesova, M. V.; Yurchenko, V. A.

    2018-01-01

    The paper is devoted to a problem of increasing the efficiency of low-potential geothermal heat in heat pump systems of residential buildings the Moscow oblast of Russia, including Moscow. Estimates of a natural geothermal potential in the Moscow oblast (based on climatological data for the period from 1982 to 2011) are presented and a "Typical climatic year of natural soil temperature variations for the geoclimatic conditions of the Moscow oblast, including the city of Moscow" is proposed. Numerical simulation of the influence of geothermal energy potential and the depth of heat wells on the efficiency of ground source heat pump systems for the heat supply of residential buildings is carried out. Analysis of the numerical simulation showed that the operation of a heat pump system in a house heating mode under the geoclimatic conditions of the Moscow oblast leads to a temperature drop of the heat-exchange medium circulating through heat wells to 5-6°C by the end of the first 10 years of operation, and the process stabilizes by the 15th year of operation, and further changes in the heat-exchange medium temperature do not any longer significantly affect the temperature of the heat-exchange medium in the heat well. In this case, the exact dependence of the heat-exchange medium temperature drop on the depth is not revealed. Data on the economically expedient heat well depth for the conditions of the Moscow oblast ensuring a net present value for the whole residential building life cycle are presented. It is found that the heat well depth of 60 m can be considered as an endpoint for the Moscow oblast, and a further heat well deepening is economically impractical.

  7. Methods for assessing the sustainability of integrated municipal waste management and energy supply systems

    Energy Technology Data Exchange (ETDEWEB)

    Luoranen, M.

    2009-07-01

    The general striving to bring down the number of municipal landfills and to increase the reuse and recycling of waste-derived materials across the EU supports the debates concerning the feasibility and rationality of waste management systems. Substantial decrease in the volume and mass of landfill-disposed waste flows can be achieved by directing suitable waste fractions to energy recovery. Global fossil energy supplies are becoming more and more valuable and expensive energy sources for the mankind, and efforts to save fossil fuels have been made. Waste-derived fuels offer one potential partial solution to two different problems. First, waste that cannot be feasibly re-used or recycled is utilized in the energy conversion process according to EU's Waste Hierarchy. Second, fossil fuels can be saved for other purposes than energy, mainly as transport fuels. This thesis presents the principles of assessing the most sustainable system solution for an integrated municipal waste management and energy system. The assessment process includes: Formation of a SISMan (Simple Integrated System Management) model of an integrated system including mass, energy and financial flows, and formation of a MEFLO (Mass, Energy, Financial, Legislational, Other decisionsupport data) decision matrix according to the selected decision criteria, including essential and optional decision criteria. The methods are described and theoretical examples of the utilization of the methods are presented in the thesis. The assessment process involves the selection of different system alternatives (process alternatives for treatment of different waste fractions) and comparison between the alternatives. The first of the two novelty values of the utilization of the presented methods is the perspective selected for the formation of the SISMan model. Normally waste management and energy systems are operated separately according to the targets and principles set for each system. In the thesis the waste

  8. The ohmic heating power supply for HL-1 tokamak

    International Nuclear Information System (INIS)

    Mingrui, Z.; Jiashun, C.

    1986-01-01

    A combination of capacitor banks, inductor and DC Fly wheel-Generator sets are used as ohmic heating power supply (OHPS) for HL-1, which is the largest tokamak in China. This system can give changeable waveform of current in a simple way, because of the use of protection for capacitor banks by changeable connection in easy way. Since the technology of forced zero current in the commutating breaker and synchronous self-triggering crowbar are used, the smooth conversion between the wave front provided by discharge of the capacitor banks and the flat top sustained by the inductor and flywheel realized. The performance of the system was tested by a dummy load and the system has been used in the HL-1 experiments. It is confirmed that this system is sufficiently available for the ohmic heating and has important effects on the long plasma lasting time on the order of 1 sec

  9. Master plan study - District heating Kohtla-Jaerve and Johvi municipalities. Estonia. Final report. Appendices for chapter 7

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The appendices to chapter 7 of the master plan study on district heating in the municipalities of Kohtla-Jarve and Johvi (Estonia) present technical data on production units, also with regard to new facilities. (ARW)

  10. Flexible and stable heat energy recovery from municipal wastewater treatment plants using a fixed-inverter hybrid heat pump system

    International Nuclear Information System (INIS)

    Chae, Kyu-Jung; Ren, Xianghao

    2016-01-01

    Highlights: • Specially designed fixed-inverter hybrid heat pump system was developed. • Hybrid operation performed better at part loads than single inverter operation. • The applied heat pump can work stably over a wide range of heat load variations. • Heat energy potential of treated effluent was better than influent. • The heat pump’s COP from the field test was 4.06 for heating and 3.64 for cooling. - Abstract: Among many options to improve energy self-sufficiency in sewage treatment plants, heat extraction using a heat pump holds great promise, since wastewater contains considerable amounts of thermal energy. The actual heat energy demand at municipal wastewater treatment plants (WWTPs) varies widely with time; however, the heat pumps typically installed in WWTPs are of the on/off controlled fixed-speed type, thus mostly run intermittently at severe part-load conditions with poor efficiency. To solve this mismatch, a specially designed, fixed-inverter hybrid heat pump system incorporating a fixed-speed compressor and an inverter-driven, variable-speed compressor was developed and tested in a real WWTP. In this hybrid configuration, to improve load response and energy efficiency, the base-heat load was covered by the fixed-speed compressor consuming relatively less energy than the variable-speed type at nominal power, and the remaining varying load was handled by the inverter compressor which exhibits a high load-match function while consuming relatively greater energy. The heat pump system developed reliably extracted heat from the treated effluent as a heat source for heating and cooling purposes throughout the year, and actively responded to the load changes with a high measured coefficient of performance (COP) of 4.06 for heating and 3.64 for cooling. Moreover, this hybrid operation yielded a performance up to 15.04% better on part loads than the single inverter operation, suggesting its effectiveness for improving annual energy saving when

  11. A Danish Heat Atlas for Supply Strategies and Demand Side Management

    DEFF Research Database (Denmark)

    Möller, Bernd

    The expansion of district heating, the assessment of the impact of heat supply strategies, as well as the analysis of significant heat demand savings require sound decision support at high detail. Data is needed to continuously quantify potentials and costs of measures in the end-use and supply...... heat demand and possible savings. The location of each building relative to heat supply technologies is mapped and used for the assessment of supply strategies by potentials, costs and environmental impact. Both elements can furthermore be used to balance investments in supply with investments...

  12. National conference on centralized heat supply from heat feeders in selected localities

    International Nuclear Information System (INIS)

    1990-05-01

    The proceedings contain 8 contributions, out of which 5 have been inputted in INIS. These deal with centralized heat supply systems, hydraulic and thermal parameters of the hot water distribution systems, and the feasibility of including nuclear sources into the systems. Treated are both actual systems and calculation models. (B.S.)

  13. Solar heating and hot water system installed at Municipal Building complex, Abbeville, South Carolina

    Science.gov (United States)

    1979-01-01

    Information on the solar energy system installed at the new municipal building for the City of Abbeville, SC is presented, including a description of solar energy system and buildings, lessons learned, and recommendations. The solar space heating system is a direct air heating system. The flat roof collector panel was sized to provide 75% of the heating requirement based on an average day in January. The collectors used are job-built with two layers of filon corrugated fiberglass FRP panels cross lapped make up the cover. The storage consists of a pit filled with washed 3/4 in - 1 1/2 in diameter crushed granite stone. The air handler includes the air handling mechanism, motorized dampers, air circulating blower, sensors, control relays and mode control unit. Solar heating of water is provided only those times when the hot air in the collector is exhausted to the outside.

  14. Investigation of a heat storage for a solar heating system for combined space heating and domestic hot water supply for homeowner´s association "Bakken"

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1998-01-01

    A heat storage for a solar heating system for combined space heating and domestic hot water supply was tested in a laboratory test facility.The heat storage consist of a mantle tank with water for the heating system and of a hot water tank, which by means of thermosyphoning is heated by the water...

  15. Water supply diagnosis in the municipality of Cajazeiras, Paraíba State, Brazil

    Directory of Open Access Journals (Sweden)

    José Adalberto da Silva Filho

    2016-04-01

    Full Text Available The water supply is a key factor for the development of the population in a region. The mapping areas that are not supplied with drinking water is an important mechanism, once the vulnerable locations are identified, which leads to establish policies and programs to mitigate the problem. Thus, this paper aims at examining areas that present vulnerability in access to water in the municipality of Cajazeiras, Paraíba State, Brazil. In order to carry this research out, data from the Brazilian Institute of Geography and Statistics were analyzed. The results indicate a disproportion in access to water between rural and urban areas, with the first being very vulnerable to contamination factors. It is necessary environmental education programs for sustainable water use, the development of technologies to ensure good quality water and the well being of the people, by the high risk of water-related diseases caused by the contamination that may occur in capture, transport and storage of water. Diagnóstico do abastecimento de água no município de Cajazeiras – PB, BrasilResumo: O abastecimento de água é um fator determinante para o desenvolvimento da população em uma região. O mapeamento de zonas que não são abastecidos com água potável é um mecanismo importante, uma vez que são identificadas as localidades que apresentam vulnerabilidade, sendo assim possível estabelecer políticas e programas que amenizem a problemática. Dessa forma, o presente trabalho tem por objetivo analisar as zonas que apresentam vulnerabilidade no acesso à água no município de Cajazeiras - PB, por meio de dados obtidos junto ao Instituto Brasileiro de Geografia e Estatística. Os resultados indicam uma desproporcionalidade no acesso à água entre as zonas rurais e urbanas, sendo a primeira muito vulnerável a fatores de contaminação. Dessa forma, faz-se necessário programas de educação ambiental para o uso sustentável da água, como também o

  16. A Direct Heat Exchanger Unit used for Domestic Hot Water Supply in a Single-family House Supplied by Low Energy District Heating

    DEFF Research Database (Denmark)

    Brand, Marek; Thorsen, Jan Eric; Svendsen, Svend

    2010-01-01

    The increasing number of new and renovated buildings with reduced heating requirements will soon make traditional District Heating (DH) systems uneconomic. To keep DH competitive in the future, the heat loss in DH networks needs to be reduced. One option is to reduce the supply temperature of DH...... as much as possible. This requires a review of the behaviour of the whole domestic hot water (DHW) supply system with focus on the user comfort and overall costs. This paper describes some practical approaches to the implementation of this Low Energy District Heating (LEDH) concept. It reports...... on the testing of the dynamic behaviour of an Instantaneous Heat Exchanger Unit(IHEU) designed for DHW heating and space heating in detached family houses supplied by LEDH ensuring an entry-to-substation temperature of 51 °C. We measured the time it takes for the IHEU to produce DHW with a temperature of 42 °C...

  17. Dual-purpose light water reactor supplying heat for desalination

    International Nuclear Information System (INIS)

    Waplington, G.; Fichtner, H.

    1978-01-01

    The technical as well as the economic aspects of using a large commercial light water reactor for the production of both electricity and potable water have been examined. For the basis of the study, the multistage flash distillation process was selected, in conjunction with a reactor rated at not less than 2100 MW (thermal). Combined use of a condensing and a back-pressure turbine (the latter matched to distillation plant steam requirements) represents a convenient method for supplying process heat. Overall costs can be fairly allocated to the two products using the ''power credit'' method. A sample economic evaluation indicates highly favorable water costs as compared with more conventional distillation schemes based on fossil fuel

  18. Investigation af a solar heating system for space heating and domestic hot water supply with a high degree of coverage

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1999-01-01

    A solar storage tank for space heating and domestic hot water supply was designed and testet in af laboratory test facility.......A solar storage tank for space heating and domestic hot water supply was designed and testet in af laboratory test facility....

  19. ON REASONABLE ESTIMATE OF ENERGY PERFORMANCE OF THE RESIDENTIAL BUILDINGS SUSTENANCE WITH CENTRALIZED HEAT-SUPPLY SYSTEM

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2016-01-01

    the period from 2006 to 2013, by virtue of the heat-supply schemes optimization and modernizing the heating systems using valuable (200–300 $US per 1 m though hugely effective preliminary coated pipes, the economy reached 2,7 MIO tons of fuel equivalent. Heat-energy general losses in municipal services of Belarus in March 2014 amounted up 17 %, whilst in 2001 they were at the level of 26 % and in 1990 – more than 30 %. With a glance to multi-staging and multifactorial nature (electricity, heat and water supply of the residential sector energy saving, the reasonable estimate of the residential buildings sustenance energy efficiency should be performed in tons of fuel equivalent in a unit of time.

  20. HEAT SUPPLY SYSTEM IMPROVEMENT OF CAMPUS AT UMAN NATIONAL UNIVERSITY OF HORTICULTURE

    Directory of Open Access Journals (Sweden)

    A. F. Golovchuk

    2016-06-01

    Full Text Available Purpose. In modern conditions of energy consumption growth and a rapid increase in energy prices the actual problem is the development and implementation of energy efficiency programs and resource-saving conversion in to a source to provide the needs of industry and municipal power. The paper aims to solve the urgent problem of energy saving and efficient use of fuel-energy ones and heat supply system optimization on the basis of Uman National University of Horticulture (UNUH. Methodology. The work investigated the process of heating and hot water supply in the course of 2007-2015 years. Implementation of current problems of energy saving is grounded on the scientific-practical and efficient assurance of fuel and energy usage. At the same time energy-saving technologies are viewed as a priority direction of the energy sector development, reduction of man-induced impact on the environment and as a way of improving the competitiveness of the national economy. Findings. Statistical data acquisition and analyzing of gas flow and outside air temperature for nine years was carried out. On the basis of this analysis, the problem was identified and specific targets for its solutions were set. Originality. Scientific novelty lies in solving the problem of energy saving and efficient use of fuel resources in Ukraine through the use of a systematic approach, the methodology development of efficient use of different fuels and optimization of local heating operation, applying contemporary automation and control systems. Firstly it was in detail analyzed and conducted the comprehensive assessment of various factors influence on energy conservation. It takes into account the human factor, professionalism and responsibility of the operators of boilers and their superiors, as well as the relevant control services. Practical value. For UNUH campus hybrid use of solid fuel and gas boilers was carried out. Decentralization of the university heating system has been

  1. A Policy study on stabilization of heating oil supply and demand

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bok Jae [Korea Energy Economics Institute, Euiwang (Korea)

    1999-03-01

    As a principal heating fuel for household and commercial sector, and a heat source fuel for industry, the heating oil shows its great demand intensively during a specific period (wintertime) due to its characteristics. It represents that the fluctuation of heating oil demand throughout the year is very extreme. Therefore, the stable supply of heating oil has been rising as an important task. It is desirable to develop and supply a new type of heating oil compounded of kerosene and gasoline with appropriate ratio for short- and mid-term to have a stable supply and demand of heating oil. For long-term prospect, it is desirable to supply petroleum products mixing gasoline and B-C oil as heating oil when it is equipped with combustion technology of boiler and distribution system. In this case, it is required to have investment on infrastructure for the supply of new heating oil (mixture of gasoline and B-C oil) and a proper preparatory period for the conversion of equipment (such as a boiler). The vitalization of storing oil is essential to stabilize the supply and demand of heating oil. In order to vitalize it, the price of heating oil should be determined by a market function reflecting the seasonal supply and demand circumstances. (author). 101 refs., 5 figs., 83 tabs.

  2. The potential to supply low temperature district heating to existing building area

    DEFF Research Database (Denmark)

    Li, Hongwei; Svendsen, Svend

    2013-01-01

    Low-temperature district heating (LTDH) has the advantages as reduced network heat loss, improved quality match between energy supply and energy demand, and increased utilization of low-grade waste heat and renewable energy. The LTDH represents the next generation district heating (DH) system...... to supply existing building areas which are characterized with high heating demand needs to be examined. In this paper, the DH network deliverable capacity to supply LTDH to an existing building area is studied based on building thermal performance and DH network hydraulic performance simulation....

  3. Heat supply of the town of Trnava from EBO nuclear plant

    International Nuclear Information System (INIS)

    Kovarik, Z.

    4 variants of central heat supply from the V-2 Bohunice nuclear power plant were considered. Three included the supply of hot water while the fourth envisaged the supply of steam. The variants of hot water supply differed in the proportion of heat supply during load peak, the range being from 75% to 88% to 100%. The system suggested considers hot water with a maximum overpressure of 2.5 MPa and temperature of 150/70 degC, with possible temporary decrease to 130/70 degC. The estimated power of heat exchange stations is 240 MW at a temperature gradient of 150/70 degC and 180 MW at a temperature gradient 130/70 degC. The location, design and control of the heat supply system and the specifications of heat generation facilities are given. (J.P.)

  4. Water governance challenges for rural supply: A case study of two local municipalities in South Africa

    CSIR Research Space (South Africa)

    Nkuna, ZW

    2012-05-01

    Full Text Available . W Nkuna Student Number: 10544403 Supervisor: Prof. C J dew. Rautenbach Department: Geography, Geo-informatics and Meteorology, University of Pretoria ABSTRACT In South Africa water is regarded as constitutional right and government has therefore... the water needs of rural communities. Issues such as poverty, water resources challenges and lack of capacity and skills at municipalities create problems which leave rural communities with no alternative but to rely on unsafe water sources for their water...

  5. Changes in municipal energy supply - revision of franchise agreements and change of ownership of networks. Proceedings. Veraenderungen der kommunalen Energieversorgung - Neugestaltung von Konzessionsvertraegen und Netzuebernahme. Tagungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, H. (ed.)

    1991-01-01

    Currently, there is a demand in many communities for information and advice on future forms of local energy supply. The present discussion was triggered by the expiry of many franchise agreements by 1994 (because of the fourth draft bill to amend the restrictive trade practices act), demands to give local government more scope for action in matters of their own power generation (reference: power-and-heat cogeneration), and endeavours on the part of local government to take over power supply also in their enlarged areas after the territorial revision. Mostly, the immediate concern is to conclude new franchise agreements (either with the former or a new utility, at identical or modified conditions) and to take over responsibility for power supply. As these are fundamental local-policy decisions with far-reaching long-term consequences, a thorough analysis is required that should include technic-economic, legal, and energy- and environment-political aspects. The book contains the lectures given at the 17th meeting of the working group 'advising on energy' in Hessen, which took place in Darmstadt on October 1st, 1990 and dealt with the complex of questions 'change of ownership of networks/franchise agreements'. The contributions demonstrate and discuss the various possibilities for framing the terms of supply in their manifold dimensions and repercussions and from different angles. This is to increase the transparency of facts, arguments and opinions regarding a complex and vital sector of municipal energy policy, and to give hints to energy advisers on difficulties and points for decision that will arise and should be taken heed of in all cases where changes of an order-political nature take place. (orig./UA).

  6. Electricity supply, district heating and supply of natural- and gas-works gas 1998

    International Nuclear Information System (INIS)

    2000-01-01

    This report is based on information covering enterprises producing, selling and transmitting electrical energy or producing and distributing hot water for district heating. The producers of electricity included in this report have either at least 100 kW in prime movers for electrical generation or at least 400 kW in prime movers and no public distribution. Enterprises are obliged by law to report these data. Data are requested concerning three types of statistical units: power stations, heating plants, and units reporting complete economic information (deliveries, sales value, production costs etc.). Power stations may be regarded as technical units and data are collected on technical equipment, consumption of fuels, production and own consumption of electrical energy. For heating plants data are collected on production and turnover of steam and hot water and on consumption of fuels and electrical energy. At the end of 1998 the installed capacity of generators amounted to 34 389 MW. Hydro-electrical capacity accounted for 48 % of total installed capacity. Compared to 1997 the capacity increased by 55 MW for hydro-electrical power and, decreased by 254 MW for conventional thermal power. Total capacity decreased by 147 MW or 0.4 %. The net production of electrical energy in 1998 amounted to 154 552 GWh, an increase of 6.4 % compared to 1997 The production of hydro-electrical power increased by 8.2 %. Hydro-electrical power accounted for 47 % of total production. Nuclear-power production increased by 6.2 % Conventional thermal-power production decreased by 28.9 %. The consumption of electricity (excl. transmission losses) increased by 0,8 % to 133 096 GWh. By consumption sectors the percentage changes were: in agriculture, etc. -9.9 %; in mining, quarrying and manufacturing +2.2 %; in construction -7.8 %; in electricity, heating, gas and water services -4.6 %; in commerce, real estate, etc. +1.8 %; in transport, storage and communication -2.9 %; in community, social

  7. Researching of the possibility of using absorption heat exchangers for creating the low return temperature heat supply systems based on CHP generation

    Science.gov (United States)

    Yavorovsky, Y. V.; Malenkov, A. S.; Zhigulina, Y. V.; Romanov, D. O.; Kurzanov, S. Y.

    2017-11-01

    This paper deals with the variant of modernization of the heat point within urban heat supply network in order to create the system of heat and cold supply on its basis, providing the suppliers with heat in cold months and with heat and cold in warm months. However, in cold months in the course of heating system operation, the reverse delivery water temperature is maintained below 40 °C. The analysis of heat and power indicators of the heat and cold supply system under different operating conditions throughout the year was conducted. The possibility to use the existing heat networks for the cold supply needs was estimated. The advantages of the system over the traditional heat supply systems that use Combined Heat and Power (CHP) plant as a heat source as exemplified by heat supply system from CHP with ST-80 turbine were demonstrated.

  8. FOLA - the district heat supply project for the Olten-Aarau region

    International Nuclear Information System (INIS)

    Utzinger, E.

    1986-01-01

    The FOLA project envisages supply of nuclear power station heat via pipe lines to communities in the Olten-Aarau region. The project is introduced with reference to environmental and oil saving advantages. Heat from the nuclear power station steam circuit converted via heat exchangers would be transmitted through pressurised hot water pipe line networks to user communities for extraction by heat exchangers at consumer installations. Some network details are discussed. The exact supply area is not yet finalised, but estimated heat loading is about 150 MW. Following further studies a construction and operating company could be formed, and heat delivery could commence in 1989. (H.V.H.)

  9. HEAT LOSS FROM HOT WATER SUPPLY LINE IN A RESIDENTIAL BUILDING

    OpenAIRE

    近藤, 修平; 鉾井, 修一

    2011-01-01

    In order to the evaluate heat loss from hot water supply lines in a residential building, hot water demand in a house in Chiba prefecture was measured and analyzed. The following results were obtained. 1. The heat loss of the hot water supply line was about 132kJ for the shower and 110kJ for the bathtub in winter. Since the temperature difference between the inlet and outlet of the hot water supply line is small, the measured heat loss from the hot water supply line sometimes becomes negative...

  10. Fundamentals about the development of the electricity supply in Germany. Challenges to a municipal power company

    International Nuclear Information System (INIS)

    Graf, Dietrich

    2016-01-01

    The roles of the different types of operators are described and particularly pointed out the duties of a municipal system operator to various examples. The implementation of the energy transition will require a fundamental change in behaviour of the customers. The possibilities of the network operator will be essentially limited to the stimulation of this change in behaviour through information and transparency. Attention is drawn to the unique, publicly accessible portal that the production and consumption situation in Hamburg is transparent in real time showing at district level.

  11. USING REGIONAL RENEWABLE ENERGY RESOURSES FOR HEATING SUPPLY SYSTEMS

    Directory of Open Access Journals (Sweden)

    O. M. Pshinko

    2017-02-01

    Full Text Available Purpose. The study analyzed the possibility and conditions for the effective operation of heating systems during the transition of the heat-generating capacity to biofuels energy. The straw of cereal crops, which are prevailing in Dnipro region, is used for this. The main purpose is scientific calculation of opportunities and cost of specific measures for such a transition. As an example it was taken the boiler-room of campus at Dnipropetrovsk National University of Railway Transport named after Academician V. Lazaryan (DNURT that consumes natural gas. Methodology. The work analyses the legislative base of Ukraine, which promotes the using of renewable energy sources as fuel, as well as the incentive mechanisms for the development of this trend. The paper identifies opportunities of Prydniprovsk region to ensure straw supply for the boiler-room. Cost parameters of cargo transportation on the territory of Ukraine in 2016, which depend on the distance and the size of the trucks, are analysed. These indicators, as well as indicators related to its purchase, are considered together with energy potential of using the straw as fuel. Findings. With existing in Ukraine (as of 2016 the grain yielding capacity in the agriculture and cost indicators in the field of transportations, the transition of capacity share to biofuel is sufficiently profitable. The thermal power unit cost can be reduced fourfold. Originality. For the first time it is proposed to use the new integrated approaches to assess the cost of thermal power unit boiler with its transition to the use of renewable energy sources. The authors also proposed a new logistics delivery of these sources to the place of their application. From a technical and cost points of view it was determined the optimal order of capacity transfer for new renewable sources of energy in a given region depending on the structure of areas under crops and their productivity. Originality. The introduction of the

  12. Development of an innovative low temperature heat supply concept for a new housing area

    OpenAIRE

    Schmidt, Dietrich; Kallert, Anna; Orozaliev, Janybek; Best, Isabelle; Vajen, Klaus; Reul, Oliver; Bennewitz, Jochen; Gerhold, Petra

    2017-01-01

    The domestic energy demand of buildings is responsible for one third of the world's final energy consumption. To increase the sustainability of new housing areas, the identification of innovative heat supply concepts based on renewable energy sources (RES) is required. For the new housing area “Zum Feldlager” (Kassel, Germany), various supply concepts are studied. Main objective is the development of an innovative and efficient supply concept based on RES and low temperature district heating ...

  13. Development of an innovative heat supply concept for a new housing area

    OpenAIRE

    Schmidt, Dietrich; Schurig, Marlen; Kallert, Anna; Orozaliev, Janybek; Best, Isabelle; Vajen, Klaus; Reul, Oliver; Bennewitz, Jochen; Gerhold, Petra

    2016-01-01

    The energy demand of buildings for heating and cooling is responsible for more than one third of the world's final energy consumption. Therefore the identification of innovative heat supply concepts based on renewable energies is required. The utilization of renewable energies in combination with efficient supply technologies increases the "sustainability" of new housing areas. For the new housing area "Zum Feldlager", located in Kassel (Germany), various supply concepts are investigated. Mai...

  14. Analysis of trends in the development of cities' heat supply systems

    Science.gov (United States)

    Stennikov, V. A.; Mednikova, E. E.

    2016-09-01

    New challenges—including the modern urban development policy, formation of the market of energy efficient technologies and different types of equipment of a broad power capacity range, tightening requirements to reliability, quality, and economic accessibility of heat supply—enhance the competitiveness of decentralized heat supply. In addition, its spontaneous growth and not always reasonable implementation lead to unjustified expenses, low efficiency, and ecological inconsistency. This proves the relevance of solving the problems of dividing an urban territory into zones of centralized heating (CH) and decentralized heating (DCH) along with their planning and justification, as well as determining a reasonable level of heat supply centralization and concentration of heat sources' power capacity. Solving these problems using the suggested method will allow optimizing the application areas for various types of heat supply and heat sources, justifying the degree of heat power capacity concentration and the extent of the systems as early as at the phase of a detailed urban planning project and then refining them during the design of urban heat supply systems. This will dramatically improve the reasonability of the decisions made and will simplify the procedure of their implementation. For criteria of limiting the extent (radius) of heat supply systems and defining their type, we suggest using standard values—the density of heat load per unit length of the pipeline and per unit area of urban territory. Standard values must be differentiated across the territory of Russia taking into account regional climatic and economic conditions and unique characteristics of heat supply development in cities and towns. The present article continues and develops the statements made in the previous articles created within the framework of the Theory of Hydraulic Circuits and takes into account the current situation and emerging trends in heat supply.

  15. Dynamic Heat Supply Prediction Using Support Vector Regression Optimized by Particle Swarm Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Meiping Wang

    2016-01-01

    Full Text Available We developed an effective intelligent model to predict the dynamic heat supply of heat source. A hybrid forecasting method was proposed based on support vector regression (SVR model-optimized particle swarm optimization (PSO algorithms. Due to the interaction of meteorological conditions and the heating parameters of heating system, it is extremely difficult to forecast dynamic heat supply. Firstly, the correlations among heat supply and related influencing factors in the heating system were analyzed through the correlation analysis of statistical theory. Then, the SVR model was employed to forecast dynamic heat supply. In the model, the input variables were selected based on the correlation analysis and three crucial parameters, including the penalties factor, gamma of the kernel RBF, and insensitive loss function, were optimized by PSO algorithms. The optimized SVR model was compared with the basic SVR, optimized genetic algorithm-SVR (GA-SVR, and artificial neural network (ANN through six groups of experiment data from two heat sources. The results of the correlation coefficient analysis revealed the relationship between the influencing factors and the forecasted heat supply and determined the input variables. The performance of the PSO-SVR model is superior to those of the other three models. The PSO-SVR method is statistically robust and can be applied to practical heating system.

  16. Possibility of Heat Pump Use in Hot Water Supply Systems

    Directory of Open Access Journals (Sweden)

    Tatyana Babak

    2016-09-01

    The results of this work may be used for in Total Site methodology development allowing heat recovery for district heating needs of both new designs and as retrofits to existing sites to ensure fast, widespread and cost-efficient industrial deployment. It leads to carbon footprint reduction and energy efficiency improvement of regions with heating and cooling demands during winter and summer seasons.

  17. Drought and Water Supply. Implications of the Massachusetts Experience for Municipal Planning.

    Science.gov (United States)

    Russell, Clifford S.; And Others

    This book uses the 1962-66 Massachusetts drought data as a base of information to build a planning model of water resources that is of interest to students and professionals involved with water management. Using a demand-supply ratio to measure the relative inadequacy of a given water system, the authors then project demand into the drought period…

  18. The Challenges of Supply Chain in the Gold Mining Sector of Obuasi Municipality of Ghana

    Directory of Open Access Journals (Sweden)

    Ernest Kwaku Agyei

    2013-10-01

    Full Text Available Gold mining industry represents an important source of socio-economic development in most economies. Ghana has had its fair share of the benefits the mining sector brings by way of direct revenue generation and job creation. In spite of this significant contribution from gold mining, the sector appears to be facing various forms of challenges. This study aims at assessing the supply chain challenges facing the gold mining operations in Obuasi and its environs in the Ashanti region of Ghana. A combination of qualitative and quantitative methods with case study strategy was used in the study. Primary data was collected from field survey through questionnaires, semi-structured interviews and observation. The data was analysed using quantitative and qualitative approaches. The major supply chain challenges found to be facing the mining sector in Obuasi include supply of low quality products, unreliable or variable lead times, non-availability of local firms of international standard, fluctuation in Gold prices on the international market, high transportation cost and violence and sporadic attack from the communities. It is recommended that the mining firms should involve their key and strategic suppliers in product designs and development of specifications. Also, improving upon information sharing and building trust and transparency and developing the capacities of their key suppliers to improve the performances of the entire supply chain could also deal with delays and quality related supplies. Finally the Ministry of Energy, the Environmental Protection Agency and other institutions should collaborate with the mining firms to deal with issues of environmental pollution and matters of perceived inadequate compensation to community members whose farm lands get destroyed by the mining activities to address any unhealthy conflicts between the mining firms and the communities.

  19. Estimation of the economical and ecological efficiency of the solar heat supply in Russia

    International Nuclear Information System (INIS)

    Marchenko, O.V.; Solomin, S.V.

    2001-01-01

    One carried out numerical study of application efficiency of solar heat supply systems in the climatic conditions of Russia with regard to their economical competitiveness with organic fuel heat conventional sources and role in reduction of greenhouse gas releases. One defined the regions where (under certain conditions) application of solar energy to generate low-potential heat may be reasonable [ru

  20. Heating of roads. Heat consumption and heat output as a function of climate, construction, demands on surface conditions and principle of heat supply. Uppvaermning av vaegar

    Energy Technology Data Exchange (ETDEWEB)

    Magnusson, R

    1977-01-01

    In this work analytical formulas for calculation of temperatures in a heated roadbed are given. The heat flux from a heated surface has been studied. The methods for snowclearence on different types of roads have been investigated. The construction work has been studied. The analytical formulas have been evaluated by comparison between calculated temperatures and temperatures measured in field and laboratory. The heat transfer coefficients in those formulas have been developed empirically by tests in laboratory and field. Surfaces with different types of traffic are divided into three classes according to the demands for snow removal. The construction work has been divided into cost elements. This has given a basis for calculating the economic effects of alternative designs. By this work has been developed a method useful on one hand for calculation of the optimum principle of regulation of the supply of heat and on the other hand for the design of the heat installations in the road.

  1. Energy Supply Modelling in Cities, Illustrated Using Data from the Municipality of Sønderborg in Denmark

    DEFF Research Database (Denmark)

    Sveinbjörnsson, Dadi Þorsteinn; Algren, Loui; Bavnhøj Hansen, Anders

    transmission networks is highest within cities, it is useful to focus on city areas when seeking to optimize the system efficiency, economy and integration. We have performed a case study using data from the Danish municipality of Sønderborg, which has the goal of becoming CO2 neutral by 2029. We have...... of fossil fuels for electricity and heat generation by 2035 and at having a fully renewable energy system by 2050. Harmonized national and regional efforts are required in order to meet these goals. As the majority of the demand for energy services is located in cities, and because the density of energy...... in which gas turbines for reserve electricity generation have been displaced by reversible electrolysis/fuel cell systems. The aim of the case study was to identify if and how new energy conversion technologies can be integrated in the future energy system to meet the demand for energy services...

  2. Yeasts and filamentous fungi in bottled mineral water and tap water from municipal supplies

    Directory of Open Access Journals (Sweden)

    Mirian Ueda Yamaguchi

    2007-01-01

    Full Text Available The main objective of this study was to analyse the occurrence of yeasts and filamentous fungi in drinking water as well as to investigate their correlation with the indicator bacteria of faecal pollution. Yeasts were detected in 36.6% and 11.6% of the bottled mineral on water dispensers and tap water samples from municipal system, respectively. Twenty-one (35.0% of bottled mineral water and two (3.3% of tap water samples were positive for filamentous fungi. For bottled mineral water 12 (20.0% of 60 samples were positive for total coliform, compared with 3(5.0%out of 60 samples from tap water. The mineral water from dispensers was more contaminated than tap water. Strains belonging to the genera Candida identified to the species level were C. parapsilosis, C. glabrata and C. albicans. Thus, bottled mineral water from water dispensers and tap water could be considered a possible transmission route for filamentous fungi and yeasts, and could constitute a potential health hazard, mainly to immunocompromised indivuals.O principal objetivo do presente estudo foi avaliar a prevalência de leveduras e fungos filamentosos em água potável, bem como investigar suas correlações com bactérias indicadoras de contaminação fecal. Leveduras foram detectadas em 36,6% e 11,6% das amostras de água mineral de garrafão em dispensadores de água e água de torneira do sistema municipal, respectivamente. Vinte e uma (35,5% das amostras de água mineral de garrafão e duas (3,3% das amostras de água de torneira foram positivas para fungos filamentosos. Para água mineral de garrafão, 12 (20.0% das 60 amostras foram positivas para coliforme total, comparado com 3 (5.0% das 60 amostras de água de torneira. A água coletada de garrafões de água mineral dos dispensadores foi marcadamente mais contaminada que as amostras de água de torneira. Candida spp identificadas ao nível de espécie foram C. parapsilosis, C. glabrata e C. albicans. Como está sendo

  3. THE OCCURANCE OF ALUMINIUM IN MUNICIPAL TREATED WATER SUPPLY OF SOUTH EAST AREA OF IRAN

    OpenAIRE

    K.Imandel; D.D. Farhud; A.Derakhtian

    1994-01-01

    In recent years, a potential connection between human intake of aluminum and Alzheimer’s disease has drawn attention to the aluminum concentration in drinking water. It is therefore of interest to investigate the aluminum concentration m drinking water, produced under different circumstances. A random selection of 152 water samples were taken by the supply source including ground, surface and a combination of both for determination of aluminum concentration in the type of water (raw, finished...

  4. Organisation of municipal gas supply; Organisation einer kommunalen Gasversorgung. Theoretische und praktische Betrachtungen

    Energy Technology Data Exchange (ETDEWEB)

    Wolters, T.

    2000-07-01

    A safe supply of gas requires more than technically secure facilities and components. A structured and suitable organisation of the company's set-up and proceeding is necessary as well. In a diploma thesis, which was honored by the DVGW, theses aspects were treated as well in theory as well as in examples. Finally, a proposel for a gas supply company was developed which offered to translate into practice the results of the thesis. The thesis discusses issues of maintaining gas supply facilities and issues of the faultclearing service as well as aspects of the worker's protection laws. (orig.) [German] Eine sichere Gasversorgung verlangt mehr als technisch sichere Anlagen und Komponenten. Hierzu ist auch besonders eine planvolle und angemessene Aufbauorganisation und Ablauforganisation des Unternehmens notwendig. In einer vom DVGW ausgezeichneten Diplomarbeit wurden diese Aspekte theoretisch und an Beispielen erarbeitet, um letztlich einem Gasversorgungsunternehmen einen konkreten Vorschlag fuer die Umsetzung des Erarbeiteten zu unterbreiten. Fragen der Instandhaltung von Gasversorgungsanlagen und des Entstoerdienstes finden ebenso Beachtung wie die Umsetzung von Forderungen aus der Arbeitsschutzgesetzgebung. (orig.)

  5. Are more resources always the answer? A supply and demand analysis for public health services in Brazilian municipalities

    Directory of Open Access Journals (Sweden)

    Fabiana Rocha

    2017-01-01

    Full Text Available The aim of this paper is to determine whether it is necessary to increase available resources to local governments or if better use of these funds is sufficient. The paper contributes to the literature by looking both at the supply and demand for public health services. If the demand is estimated correctly, one can compare its expected value to actual health expenditures. Even if actual expenditures are lower than the estimated demand, it is not certain that additional spending is necessary. If the efficiency scores (supply side indicate that local governments can simply “save” resources to make up for the difference, then it is possible to reduce (or bring to zero new resources only by requiring local governments to efficiently manage their expenditures. Since municipalities in Brazil are very heterogeneous, we estimate their efficiency using the metafrontier approach (O’Donnell et al., 2008, while we estimate the demand through an equation derived from the median voter theorem model. Using 2010 data, we find evidence that efficient management of spending is sufficient to meet excess demand for goods and services in the health sector.

  6. 100% energy supply coverage with renewable energy. Requirements for its implementation at the global, national and municipal level

    International Nuclear Information System (INIS)

    Rogall, Holger

    2014-01-01

    This book presents itself as a systematic, easily understandable introduction into the requirements for an energy supply based 100% on renewable energy. Its main focus is on the strategic paths that must be followed for this purpose in the realms of business, technology and governmental policy. It highlights the opportunities and impediments on the way, analysing in the process the roles of political, economic and civil society players from the global down to the municipal level. Starting out from the present state of discussion on the German energy transition it investigates the strengths and weak points of efficiency technologies and renewable energies available today and elaborates a strategic path for developing the necessary infrastructure. In awareness of the fact that 100% coverage will not come about from market mechanisms alone it explores the ecological crash barriers that need to be set up in addition. This is followed by chapters on the roles, interests and means of those players who can exert influence on the framing of the relevant political and legal instruments as well as their means of pursuing their interests. The book thus contributes to clarifying the possibilities of and impediments to achieving an energy supply system based 100% on renewable energy.

  7. Partial costs of global climate change adaptation for the supply of raw industrial and municipal water: a methodology and application

    International Nuclear Information System (INIS)

    Ward, Philip J; Pauw, W Pieter; Brander, Luke M; Aerts, Jeroen C J H; Strzepek, Kenneth M; Hughes, Gordon A

    2010-01-01

    Despite growing recognition of the importance of climate change adaptation, few global estimates of the costs involved are available for the water supply sector. We present a methodology for estimating partial global and regional adaptation costs for raw industrial and domestic water supply, for a limited number of adaptation strategies, and apply the method using results of two climate models. In this paper, adaptation costs are defined as those for providing enough raw water to meet future industrial and municipal water demand, based on country-level demand projections to 2050. We first estimate costs for a baseline scenario excluding climate change, and then additional climate change adaptation costs. Increased demand is assumed to be met through a combination of increased reservoir yield and alternative backstop measures. Under such controversial measures, we project global adaptation costs of $12 bn p.a., with 83-90% in developing countries; the highest costs are in Sub-Saharan Africa. Globally, adaptation costs are low compared to baseline costs ($73 bn p.a.), which supports the notion of mainstreaming climate change adaptation into broader policy aims. The method provides a tool for estimating broad costs at the global and regional scale; such information is of key importance in international negotiations.

  8. Partial costs of global climate change adaptation for the supply of raw industrial and municipal water: a methodology and application

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Philip J; Pauw, W Pieter; Brander, Luke M; Aerts, Jeroen C J H [Institute for Environmental Studies (IVM), VU University Amsterdam (Netherlands); Strzepek, Kenneth M [Joint Program on the Science and Policy of Global Change, Massachusetts Institute of Technology, MA (United States); Hughes, Gordon A, E-mail: philip.ward@ivm.vu.nl [School of Economics, University of Edinburgh (United Kingdom)

    2010-10-15

    Despite growing recognition of the importance of climate change adaptation, few global estimates of the costs involved are available for the water supply sector. We present a methodology for estimating partial global and regional adaptation costs for raw industrial and domestic water supply, for a limited number of adaptation strategies, and apply the method using results of two climate models. In this paper, adaptation costs are defined as those for providing enough raw water to meet future industrial and municipal water demand, based on country-level demand projections to 2050. We first estimate costs for a baseline scenario excluding climate change, and then additional climate change adaptation costs. Increased demand is assumed to be met through a combination of increased reservoir yield and alternative backstop measures. Under such controversial measures, we project global adaptation costs of $12 bn p.a., with 83-90% in developing countries; the highest costs are in Sub-Saharan Africa. Globally, adaptation costs are low compared to baseline costs ($73 bn p.a.), which supports the notion of mainstreaming climate change adaptation into broader policy aims. The method provides a tool for estimating broad costs at the global and regional scale; such information is of key importance in international negotiations.

  9. Biomass Supply Planning for Combined Heat and Power Plants using Stochastic Programming

    DEFF Research Database (Denmark)

    Guericke, Daniela; Blanco, Ignacio; Morales González, Juan Miguel

    method using stochastic optimization to support the biomass supply planning for combined heat and power plants. Our two-phase approach combines mid-term decisions about biomass supply contracts with the short-term decisions regarding the optimal market participation of the producer to ensure......During the last years, the consumption of biomass to produce power and heat has increased due to the new carbon neutral policies. Nowadays, many district heating systems operate their combined heat and power (CHP) plants using different types of biomass instead of fossil fuel, especially to produce......, and heat demand and electricity prices vary drastically during the planning period. Furthermore, the optimal operation of combined heat and power plants has to consider the existing synergies between the power and heating systems while always fulfilling the heat demand of the system. We propose a solution...

  10. Method and means for heating buildings in a district heating system with waste heat from a thermal power plant

    International Nuclear Information System (INIS)

    Margen, P.H.E.

    1975-01-01

    The waste heat from a thermal power plant is transported through a municipal heating network to a plurality of buildings to be heated. The quantity of heat thus supplied to the buildings is higher than that required for the heating of the buildings. The excess heat is released from the buildings to the atmosphere in the form of hot air

  11. Master plan study - District heating Kohtla-Jaerve and Johvi municipalities. Estonia. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The main deficiencies of the district heating system in Kohtla-Jaerve, Ahtme and Johvi (Estonia) were identified as being: Inefficiency of the heat and power production plants; Lack of means for the consumers to control their consumption of energy due to the existing constant flow system; The environmental impact from heat and power production based on oil shale; Water and heat losses from the network; Low heat intensity in the Johvi area. Investigations indicate that improvement should have first priority at the Kohtla-Jaerve power plant, total investment is estimated at US D 60,3 million, of which US D 48 million are foreign costs. The cash flow will be negative in the first half of the projects lifetime. Estii Energia should be involved in the financing of the project. At the present price level, introduction of variable flow does not significantly improve the financial viability of the project, and the improvement of the district heating system might be carried out at a later stage, when the tariff has found a more stable level and the financial viability will be more significant. Implementation of new boilers in the Kohtla-Jaerve power plant. Circulating Fluidized Bed boilers, as well as electrostatic filters and estimated to reduce the environmental impact considerably. A more in depth study of the environmental impact from utilisation of oil shale should be carried out, also in order to inform possible investors of risk of investing in the oil shale industry. It will be more expensive to supply Johvi as an independent district heating system than if Johvi is supplied from Ahtme. The results arrived at are based on a range of the crucial assumptions that: the price of oil shale is expected to reach 75% of the price of coal, the sales price of electricity from plants is 62% of the consumer price, the exchange rate of the Estonian currency is kept constant to the DEM and that the inflation is Estonia will decline from 21% to 2,3% in 2005. (ARW)

  12. SOME FEATURES OF THE POWER SUPPLY OF RESIDENTIAL BUILDINGS DURING THE HEATING SEASON

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2017-01-01

    Full Text Available A large proportion of consumption of different types of energy by the residential sector, especially in the heating period, makes the energy efficiency of buildings without considering the loss of fuel with a significant reduction in hourly load on the generators, especially at night, already insufficient for real energy savings. Therefore in Belarus, in order to attract the consumer, electricity tariff for heating at night hours (from 11 p.m. to 6.00 a.m. is three times cheaper than at any other time. Significant increase of the electricity consumption of at night could be achieved by using heat accumulators for heating and hot water supply to the residential sector. Particularly effective are water accumulators of heat and accumulators of underfloor heating that enable to use a coolant with a temperature of 40 оC and to increase the useful supply of heat. The use of heat accumulators for daily heating, ventilation and hot water supply of buildings significantly reduces the cost of creating the infrastructure of the territory under construction by eliminating the necessity of running the distribution network of heat or gas supply. The use of the heat accumulators is necessary due to the increase of the time-weighted average outdoor temperature. The mentioned increase in the City of Minsk in the heating season is of about 0.1 °C per year in average, and as for the last 20 years, the increase has led to a reduction of the required heat load on the premises by about 10 %. Research and project work on choosing the most effective options for the arrangement and use the heat accumulators in buildings of the various functions ought to be fulfilled in order to make the application of heat accumulators successful. In this respect civil and power engineers as well as operators should work together so to determine the chronological, technical and economic conditions of charging and use of heat accumulators.

  13. Estimation of transient heat flux density during the heat supply of a catalytic wall steam methane reformer

    Science.gov (United States)

    Settar, Abdelhakim; Abboudi, Saïd; Madani, Brahim; Nebbali, Rachid

    2018-02-01

    Due to the endothermic nature of the steam methane reforming reaction, the process is often limited by the heat transfer behavior in the reactors. Poor thermal behavior sometimes leads to slow reaction kinetics, which is characterized by the presence of cold spots in the catalytic zones. Within this framework, the present work consists on a numerical investigation, in conjunction with an experimental one, on the one-dimensional heat transfer phenomenon during the heat supply of a catalytic-wall reactor, which is designed for hydrogen production. The studied reactor is inserted in an electric furnace where the heat requirement of the endothermic reaction is supplied by electric heating system. During the heat supply, an unknown heat flux density, received by the reactive flow, is estimated using inverse methods. In the basis of the catalytic-wall reactor model, an experimental setup is engineered in situ to measure the temperature distribution. Then after, the measurements are injected in the numerical heat flux estimation procedure, which is based on the Function Specification Method (FSM). The measured and estimated temperatures are confronted and the heat flux density which crosses the reactor wall is determined.

  14. Monitoring of Hazardous Inorganic Pollutants and Heavy Metals in Potable Water at the Source of Supply and Consumers end of a Tropical Urban Municipality

    International Nuclear Information System (INIS)

    Shah, A. B.; Singh, R. P.

    2016-01-01

    River water is not only an indispensable source for irrigation but also plays a vital role for drinking water supply for most of the urban municipalities. Water from rivers is pumped at specific sites and after treatment at municipal water treatment plants supplied as domestic potable water supply. The present study was undertaken to assess the suitability of Gomti river water at Gaughat being used as the source of water supply for Lucknow city and to evaluate post-treatment potable water quality at the consumer end by monitoring the levels of inorganic pollutants (nitrate, nitrite, ammonium and phosphate) and heavy metals. Municipal water supply at Gaughat showed marked variations in the levels of p H (7.13-8.63) and electrical conductivity (375.66-571.67μS/cm). The amount of nitrate, nitrite, ammonium and phosphate was observed 26.25, 0.082, 6.9 and 1.82 mg/l respectively at Gaughat. Also, the levels of heavy metals in the municipal water source at Gaughat varied significantly for Fe (0.33-1.65 mg/l), Cu (0.077-0.108 mg/l), Cd (0.03-0.052 mg/l), Pb (0.68-0.96 mg/l) and Cr (0.036-0.065 mg/l). Water at the user end was also contaminated as the concentration of analysed inorganic pollutants and heavy metals were correspondingly higher than observed at the source. While comparing potable water at the user end of Lucknow municipality with the BIS (Drinking Water Specifications) and WHO standards for drinking water, the concentration of all studied heavy metals and other inorganic contaminants were much above the permissible levels, thus posing a serious threat to the public health.

  15. EFFECTIVENESS ANALYSIS OF CAMPUS HEAT SUPPLY SYSTEM OF DNIPROPETROVSK NATIONAL UNIVERSITY OF RAILWAY TRANSPORT

    Directory of Open Access Journals (Sweden)

    O. M. Pshinko

    2014-03-01

    Full Text Available Purpose. Heat consumption for heating and hot water supply of housing and industrial facilities is an essential part of heat energy consumption. Prerequisite for development of energy saving measures in existing heating systems is their preliminary examination. The investigation results of campus heating system of Dnipropetrovsk National University of Railway Transport named after Academician V. Lazaryan are presented in the article. On the basis of the analysis it is proposed to take the energy saving measures and assess their effectiveness. Methodology. Analysis of the consumption structure of thermal energy for heating domestic and hot water supply was fulfilled. The real costs of heat supply during the calendar year and the normative costs were compared. Findings. The recording expenditures data of thermal energy for heating supply of residential buildings and dormitories in 2012 were analyzed. The comparison of actual performance with specific regulations was performed. This comparison revealed problems, whose solution will help the efficient use of thermal energy. Originality. For the first time the impact of climate conditions, features of schemes and designs of heating systems on the effective use of thermal energy were analyzed. It was studied the contribution of each component. Practical value. Based on the analysis of thermal energy consumption it was developed a list of possible energy saving measures that can be implemented in the system of heat and power facilities. It was evaluated the fuel and energy resources saving.

  16. Environmental Aspects as Assessment Criteria in Municipal Heat Energy Decisions - Case of Eno Energy Cooperative

    Energy Technology Data Exchange (ETDEWEB)

    Puhakka, Asko [North Karelia Univ. of Applied Sciences, Joensuu (Finland)

    2006-07-15

    The aim of this paper is to provide information whether it is possible to consider the sustainable development perspectives in the decision making of the district energy decision. The new EU-directives concerning public procurements allow the use of environmental aspects as selection criteria. The focus here is on small-scale district heating systems and their fuel-supply chains. The comparable fuels included the analysis are forest chips, heavy fuel oil, light fuel oil and peat. The paper focuses to the concept of the sustainable development and establishes the indicators for ecological-, social- and economical aspects of the district heating. The indicators are utilized in the case study on the Eno Energy Cooperative. The equivalent CO{sub 2} emissions from the production and the combustion of the fuel, the employment impacts of the fuel production and the formation of the price of energy for the consumers are considered. After presenting the sustainable development indicators in the case of Eno Energy Cooperative, the investment models of heat entrepreneurship business are discussed. Finally, we also raise an attention into important aspects to be considered when establishing a local district heating scheme. The indicators used in this presentation show that the use of forest chips in energy production has positive effect through the reduced greenhouse gases. The use of wood in energy production also provides employment opportunities and is more favourable to consumers, because of the steady fuel price when compared to other alternative fuels.

  17. Prospects for jointly using solar and wind energy for heat supply and hot water supply to private houses under the conditions of Baku

    International Nuclear Information System (INIS)

    Salamov, O. M.; Aliev, F. F.

    2013-01-01

    This paper analyzes the discovery of the potential for jointly using solar and wind energy for heat supply (HS) and hot water supply (HWS) to a one-family private house located in the Apsheron Peninsula. (authors)

  18. EXPERIENCE OF UTILIZATION OF CAPACITY BANKS AND SCHEMES OF FREQUENCY REGULATION IN MUNICIPAL CENTRALIZED HEATING SYSTEM OF CHISINAU

    Directory of Open Access Journals (Sweden)

    CHERNEI M

    2013-04-01

    Full Text Available The current paper provides a brief summary of the district heating system of the municipality Chisinau, including heat power sources, heat distribution network, production and consumption development over the past two decades and other data. Also, the priority investment projects realized by JSC "Termocom" are being presented. The company had implemented an automated monitoring system for the heat power production, transportation and distribution. For many years, the company used bellows pipes with polyurethane insulation, ball valves and plate heat exchangers. 14 out of 21 district heating boiler stations were upgraded 10 were completely automated having as a result no further need in full-time duty personnel there. The experience gained in the implementation of capacity banks and frequency inverters, summarizing the benefits and achieved results, is also presented in the current paper. It is to be underlined that in 2011 the company achieved decrease in electricity consumption by about 30% in comparison with 2005.

  19. Investigation of a solar heating system for space heating and domestic hot water supply for Sol&Træ A.m.b.a

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1999-01-01

    A solar heating system for space heating and domestic hot water supply from "Sol&Træ A.m.b.a." was tested in a laboratory test facility.......A solar heating system for space heating and domestic hot water supply from "Sol&Træ A.m.b.a." was tested in a laboratory test facility....

  20. Investigation of a low flow solar heating system for space heating and domestic hot water supply for Aidt Miljø A/S

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1997-01-01

    A low flow solar heating system for space heating and domestic hot water supply from Aidt Miljø A/Swas tested in a laboratory test facility.......A low flow solar heating system for space heating and domestic hot water supply from Aidt Miljø A/Swas tested in a laboratory test facility....

  1. Using System Dynamics to Explore the Water Supply and Demand Dilemmas of a Small South African Municipality

    NARCIS (Netherlands)

    Clifford Holmes, J.K.; Slinger, J.H.; Musango, J.K.; Brent, A.C.; Palmer, C.G.

    2014-01-01

    This paper explores the challenges faced by small municipalities in providing water services in a developing-world context of increasing urban demand. The paper uses a case study of the Sundays River Valley Municipality (SRVM) in South Africa. The municipality faces multiple dilemmas in reconciling

  2. A multi-echelon supply chain model for municipal solid waste management system

    International Nuclear Information System (INIS)

    Zhang, Yimei; Huang, Guo He; He, Li

    2014-01-01

    In this paper, a multi-echelon multi-period solid waste management system (MSWM) was developed by inoculating with multi-echelon supply chain. Waste managers, suppliers, industries and distributors could be engaged in joint strategic planning and operational execution. The principal of MSWM system is interactive planning of transportation and inventory for each organization in waste collection, delivery and disposal. An efficient inventory management plan for MSWM would lead to optimized productivity levels under available capacities (e.g., transportation and operational capacities). The applicability of the proposed system was illustrated by a case with three cities, one distribution and two waste disposal facilities. Solutions of the decision variable values under different significant levels indicate a consistent trend. With an increased significant level, the total generated waste would be decreased, and the total transported waste through distribution center to waste to energy and landfill would be decreased as well

  3. A multi-echelon supply chain model for municipal solid waste management system

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yimei, E-mail: yimei.zhang1@gmail.com [Energy and Environmental Research Academy, North China Electric Power University, Beijing 102206 (China); Huang, Guo He [Environmental Systems Engineering Program, Faculty of Engineering and Applied Science, University of Regina, Regina, Saskatchewan S4S 0A2 (Canada); He, Li [Energy and Environmental Research Academy, North China Electric Power University, Beijing 102206 (China)

    2014-02-15

    In this paper, a multi-echelon multi-period solid waste management system (MSWM) was developed by inoculating with multi-echelon supply chain. Waste managers, suppliers, industries and distributors could be engaged in joint strategic planning and operational execution. The principal of MSWM system is interactive planning of transportation and inventory for each organization in waste collection, delivery and disposal. An efficient inventory management plan for MSWM would lead to optimized productivity levels under available capacities (e.g., transportation and operational capacities). The applicability of the proposed system was illustrated by a case with three cities, one distribution and two waste disposal facilities. Solutions of the decision variable values under different significant levels indicate a consistent trend. With an increased significant level, the total generated waste would be decreased, and the total transported waste through distribution center to waste to energy and landfill would be decreased as well.

  4. A multi-echelon supply chain model for municipal solid waste management system.

    Science.gov (United States)

    Zhang, Yimei; Huang, Guo He; He, Li

    2014-02-01

    In this paper, a multi-echelon multi-period solid waste management system (MSWM) was developed by inoculating with multi-echelon supply chain. Waste managers, suppliers, industries and distributors could be engaged in joint strategic planning and operational execution. The principal of MSWM system is interactive planning of transportation and inventory for each organization in waste collection, delivery and disposal. An efficient inventory management plan for MSWM would lead to optimized productivity levels under available capacities (e.g., transportation and operational capacities). The applicability of the proposed system was illustrated by a case with three cities, one distribution and two waste disposal facilities. Solutions of the decision variable values under different significant levels indicate a consistent trend. With an increased significant level, the total generated waste would be decreased, and the total transported waste through distribution center to waste to energy and landfill would be decreased as well. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Various methods of heat supply for a building which is operated periodically during the year

    Science.gov (United States)

    Małetka, Marek; Laska, Marta

    2017-11-01

    Stand-alone buildings operated periodically require heat supply for hot water and heating purposes to be carefully analyzed in terms of the technical capabilities, the energy and financial outlays. The paper presents the analysis of heat supply for hot water purposes and central heating in the stand-alone cloakroom building located in Poland. The analysis is undertaken for different variants of heat delivery for a building from electric heaters, gas boiler and district heating solutions to renewable sources applications, namely solar panels and heat pumps. For each solution, usage of usable, final and primary energy was calculated. Also the financial analysis for investments and energy costs were carried out. This analysis has been done in according to SPBT and NPV method for different levels of building use.

  6. Various methods of heat supply for a building which is operated periodically during the year

    Directory of Open Access Journals (Sweden)

    Małetka Marek

    2017-01-01

    Full Text Available Stand-alone buildings operated periodically require heat supply for hot water and heating purposes to be carefully analyzed in terms of the technical capabilities, the energy and financial outlays. The paper presents the analysis of heat supply for hot water purposes and central heating in the stand-alone cloakroom building located in Poland. The analysis is undertaken for different variants of heat delivery for a building from electric heaters, gas boiler and district heating solutions to renewable sources applications, namely solar panels and heat pumps. For each solution, usage of usable, final and primary energy was calculated. Also the financial analysis for investments and energy costs were carried out. This analysis has been done in according to SPBT and NPV method for different levels of building use.

  7. Multipurpose nuclear process heat for energy supply in Brazil

    International Nuclear Information System (INIS)

    Hansen, U.; Inden, P.; Oesterwind, D.; Hukai, R.Y.; Pessine, R.T.; Pieroni, R.R.; Visoni, E.

    1978-11-01

    The industrialized nations require 75% of the energy as heat and it is likely that developing countries in the course of industrialization will show a comparable energy consumption structure. The High Temperature Reactor (HTR) allows the utilization of nuclear energy at high temperatures as process heat. In the Federal Republic of Germany (FRG) the development in the relevant technical areas is well advanced and warrants investigation as a matter for transfer to Brazil. In Brazil nuclear process heat finds possible applications in steel making, shale oil extraction, petroleum refining, and in the more distant future coal gasification with distribution networks. Based on growth forecasts for these industries a theoretical potential market of 38-53 GW (th) can be identified. At present nuclear process heat is marginally more expensive than conventional fossil technologies but the anticipated development is expected to add an economic incentive to the emerging necessity of providing a sound energy base in the developing countries. (author)

  8. Current contributions on the technical thermodynamics, power engineering and district heating supply. Special publication; Aktuelle Beitraege zur technischen Thermodynamik, Energietechnik und Fernwaermeversorgung. Sonderveroeffentlichung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-03-15

    Within the special publication under consideration, the German Heat and Power Association (Frankfurt (Main), Federal Republic of Germany) presents the following current contributions on the technical thermodynamics, power engineering and district heating supply: (1) Cellular metallic materials for innovative latent heat accumulator technologies (Jens Meinert); (2) Compressed air storage - technology, chances and problems (Rutger Kretschmer); (3) KWK electricity - Identification and evaluation (Matthias Krause); (4) Investigation of the storage ability of district heating grids and implementation into the optimized planning of heat generators (Sebastian Gross); (5) Autarcic thermal densification to the combined heat and power and cooling production? - A fundamental thermodynamic consideration (Torben Moeller); (6) Modelling of cogeneration power plants - Investigation of the transformation opportunity of existing district heating systems in LowEx grids (Martin Rhein); (7) Discrete building model for the dynamic thermohydraulic simulation of district heating (Dominik Haas); (8) Ventilation and degasification of solar power plants (Karin Ruehling); (9) Integral simulation of district heating with TRNSYS-TUD (Steffen Robbi); (10) Theoretical analyses of return temperatures in building heating networks (Andreas Meinzenbach); (11) Municipal energy efficiency as an important contribution to the reduction of greenhouse gas emissions (Matthias Mischke); (12) Investigation of the latent heat storage system PK 6 for use in air-conditioning installations (Sebastian Pinnau); (13) The role of the thermodynamics in the electromobility (Lars Schinke); (14) Flow and heat transfer in cooling channels with methane (Andre Schlott); (15) Numerical calculations of stoves fired with wooden logs (Ulf Senechal); (16) Supply of thermodynamic substance data for working fluids of power engineering (Hans-Joachim Kretzschmar); (17) Cyclic pipe-ground interaction in solar-thermal heat grids

  9. Optimized district heating supply temperature for large networks; Optimerad framledningstemperatur foer stora fjaerrvaermenaet

    Energy Technology Data Exchange (ETDEWEB)

    Saarinen, Lisa; Boman, Katarina

    2012-02-15

    The supply temperature of the Uppsala district heating network was optimized using a model-based control strategy. Simulation of the network showed that the supply temperature could be decreased by in average 8 deg and the electricity production of the plants supplying the network could be increased with 2.5 % during the period January- April, giving an extra income of 1.2 MSEK due to increased income from electricity sales

  10. Combined installation of electric and heat supply for climatic conditions of Iraq

    Science.gov (United States)

    Kaisi, Osama Al; Sidenkov, D. V.

    2017-11-01

    Electricity, heating and cooling are the three main components that make up the energy consumption base in residential, commercial and public buildings around the world. Demand for energy and fuel costs are constantly growing. Combined cooling, heating and power generation or trigeneration can be a promising solution to such a problem, providing an efficient, reliable, flexible, competitive and less harmful alternative to existing heat and cold supply systems. In this paper, scheme of the tri-generation plant on non-aqueous working substances is considered as an installation of a locally centralized electro-heat and cold supply of a typical residential house in a hot climate. The scheme of the combined installation of electro-heat (cold) supply consisted of the vapor power plant and heat pump system on low-boiling working substance for local consumers under the climatic conditions of Iraq is presented. The possibility of using different working substances in the thermodynamic cycles of these units, which will provide better efficiency of such tri-generation systems is shown. The calculations of steam turbine cycles and heat pump part on the selected working substances are conducted. It is proposed to use heat exchangers of plate type as the main exchangers in the combined processing. The developed method of thermal-hydraulic calculation of heat exchangers implemented in MathCad, which allows to evaluate the efficiency of plants of this type using the ε - NTU method. For the selected working substances of the steam part the optimal temperature of heat supply to the steam generator is determined. The results of thermodynamic and technical-economic analysis of the application of various working substances in the “organic” Rankine cycle of the steam turbine unit and the heat pump system of the heat and cold supply system are presented.

  11. Fluidized-bed incineration plant equipped with waste heat boilers. Developed for mid-size municipalities

    Energy Technology Data Exchange (ETDEWEB)

    Handa, Hitoshi

    1988-01-20

    A fluidized bed incineration plant with a waste heat boiler was installed to dispose wastes in Sakura City on March, 1987 and has waste disposing capacity of 120tons/d. Sands are fluidized in the furnace at 700-800/sup 0/C and wastes are burned completely for a short time. The waste heat boiler is used to utilize waste heat to send steam to aquiculturing farms and hot water to the community plaza and further supplies steam to two 90kW back pressure turbines for driving forced draft fan used for the incineration plant. Harmful gases in waste gas are removed by the harmful gas eliminator to lower HCl to 120ppm or less and K value of SOx to 9.0 or less and then cleaned gas is exhausted through the electostatic precipitator and the chimney. Dust and fly ash are transferred to a reservior through a superior seal tight air transportation system, pelletized and disposed for land fill. Bulk waste disposing capacity is 50 tons/d and harmful wastes, magnetic materials, unburnable and burnable wastes are classified and separated. Separated iron purity is 95% or more. (4 figs, 2 photos)

  12. Effects of boosting the supply temperature on pipe dimensions of low-energy district heating networks

    DEFF Research Database (Denmark)

    Tol, Hakan; Svendsen, Svend

    2015-01-01

    This paper presents a method for the dimensioning of the low-energy District Heating (DH) piping networks operating with a control philosophy of supplying heat in low-temperature such as 55 °C in supply and 25°C in return regularly while the supply temperature levels are being boosted in cold...... winter periods. The performance of the existing radiators that were formerly sized with over-dimensions was analyzed, its results being used as input data for the performance evaluation of the piping network of the low-energy DH system operating with the control philosophy in question. The optimization...

  13. PECULIARITIES OF FORMATION OF CORPORATE STRUCTURES IN THE HEAT SUPPLY SYSTEM OF THE REGION

    Directory of Open Access Journals (Sweden)

    Oleg A. Donichev

    2013-01-01

    Full Text Available The article contains the research results of formation and functioning of corporate structures of the regional heat power engineering. A geometrical model of interactions between hierarchy levels of this structure is proposed. The role of the government in an improvement of the effectiveness of the heat supply system of regions is proved.

  14. Use of solar energy for heat supply under conditions of the Socialist Federated Republic of Yugoslavia

    Energy Technology Data Exchange (ETDEWEB)

    Savic, B.

    1981-01-01

    The characteristics of a flat solar energy collector are used to determine the specific heat productivity of the solar unit under meteorological conditions of Belgrade. The evaluation is made with regard for experimental data of year-round operation of hot water supply units and the seasonal use of heating units.

  15. Assessment of heavy metals in the industrial effluents, tube-wells and municipal supplied water of Dehradun, India.

    Science.gov (United States)

    Kulshrestha, Shail; Awasthi, Alok; Dabral, S K

    2013-07-01

    The bio-geochemical cycles of metals involve the lands, rivers, oceans and the atmosphere. Although a large number of metals are introduced to the water bodies during their mining and extraction processes and geochemical weathering of rocks, but the role of domestic and industrial wastes is predominant and of much concern. Increased industrial activities has increased the incidence of percolation of toxic metal ions to the soil and water bodies and presently their presence in ecosystem, have reached to an alarming level that environmentalists are finding it difficult to enforce control measures. Human activities and large number of small and big industrial units are increasingly discharging deleterious metals present in the effluents and wastes, to the environment and aquatic systems and have contaminated heavily even the ground water. The toxic metals have a great tendency of bioaccumulation through which they enter the food chain system and ultimately affect adversely the life on this planet Earth in various ways. Further, due to contamination of irrigation system by the harmful Chemicals and toxic metals, the farm products, vegetables, fruits, potable water and even milk is not spared. This paper describes the assessment of the heavy metal concentration in various industrial effluents of the surrounding area. Various physico-chemical characteristics of the effluents collected from various sites are also reported. To assess the status of ground water quality, water samples from four tube wells of different localities of the area and four drinking water samples supplied by Municipal Distribution System were also analyzed.

  16. Performance of Chilled Beam with Radial Swirl Jet and Diffuse Ceiling Air Supply in Heating Mode

    DEFF Research Database (Denmark)

    Bertheussen, Bård; Mustakallio, Panu; Melikov, Arsen Krikor

    2013-01-01

    ). The room air temperature was kept at 21 °C. Tracer gas was used to simulate pollution from floor and desk. The experimental conditions comprised: 1) night time without heat sources in the room; the room air conditioning system was used to heat up the room; 2) heat load generated by an occupant (simulated...... by dressed thermal manikin) and a laptop; 3) heating by convectors positioned under the window (convectors used alone and convector used together with CSW supplying isothermal air for ventilation). The heat distribution provided by the systems was not effective compare to the distribution provided......The performance of diffuse ceiling air supply and chilled beam with swirl jet (CSW) in heating mode (winter situation) was studied and compared with regard to the generated indoor environment. An office mock-up with one occupant was simulated in a test room (4.5 x 3.95 x 3.5 m3 (L x W x H...

  17. PV Thermal systems: PV panels supplying renewable electricity and heat

    NARCIS (Netherlands)

    Helden, van W.G.J.; Zolingen, van R.J.C.; Zondag, H.A.

    2004-01-01

    With PV Thermal panels sunlight is converted into electricity and heat simultaneously. Per unit area the total efficiency of a PVT panel is higher than the sum of the efficiencies of separate PV panels and solar thermal collectors. During the last 20 years research into PVT techniques and concepts

  18. Comparative ecobalancing accounting of semi-central house heat supply from wood residues

    International Nuclear Information System (INIS)

    Biemann, Kirsten

    2015-01-01

    In 2008 almost 40 percent of the German final energy demand was used for room heating and hot water supply. To decrease environmental burdens and to save fossil resources a restructuring of the heating sector is needed. Therefore legislation enforces higher insulation standards of buildings and a more frequent use of renewable energies as well as heating networks. Wood as a renewable and storable energy source is an attractive fuel. However, it must be used as efficiently as possible because of limited wood supplies. Connecting buildings via a heating network is a good option since bigger heating plants can operate at higher efficiencies than small heaters. However, the higher insulation standards of the buildings often oppose the construction of a heating network, because heating networks work best with high energy demands and low network lengths. Therefore the environmental and economic feasibility of new heating networks needs to be checked beforehand. This thesis explores the environmental burdens of different semi- centralized heating networks using wood residues as fuel. A semi- centralized heating network is a network with no more than 500 customers and a heating plant with less than 5 MWth. While wood residues are used in the base load plant, peak load is covered by a gas heating plant. As a method to analyze the potential environmental burdens of the heat supply a life cycle assessment according to ISO 14040/44 is used. Opposed to former life cycle assessment studies, construction and operation of the network is included in the assessment. Even though the environmental impacts of the semi- centralized heating from wood residues are dominated by the heat supply, an observation of the impacts solely at the heating plant is not sufficient. By varying the boundary conditions of the heating network two main contributors to the environmental impacts are found. In addition to the heat production at the plant the type of the buildings in the settlement has a huge

  19. Stochastic Programming for Fuel Supply Planning of Combined Heat and Power Plants

    DEFF Research Database (Denmark)

    Guericke, Daniela; Blanco, Ignacio; Morales González, Juan Miguel

    The consumption of biomass to produce power and heat has increased due to the carbon neutral policies. Combined heat and power (CHP) plants often combine biomass with other fuels, e.g., natural gas. The negotiation process for supply contracts involves many uncertainties due to the long planning...... horizon. The demand for biomass is uncertain, and heat demand and electricity prices vary during the planning period. We propose a method using stochastic optimization to support the biomass and natural gas supply planning for CHP plants including short-term decisions for optimal market participation....

  20. Integration of Space Heating and Hot Water Supply in Low Temperature District Heating

    DEFF Research Database (Denmark)

    Elmegaard, Brian; Ommen, Torben Schmidt; Markussen, Michael

    2014-01-01

    pipes, where the water is at the highest temperature. The heat loss may be lowered by decreasing the temperatures in the network for which reason low temperature networks are proposed as a low loss solution for future district heating. However, the heating demand of the consumers involve both domestic......District heating makes it possible to provide heat for many consumers in an efficient manner. In particular, district heating based on combined heat and power production is highly efficient. One disadvantage of district heating is that there is a significant heat loss from the pipes...... to the surrounding ground. In larger networks involving both transmission and distribution systems, the heat loss is most significant from the distribution network. An estimate is that about 80-90 % of the heat loss occurs in the distribution system. In addition, the heat loss is naturally highest from the forward...

  1. Reduced heat stress in offices in the tropics using solar powered drying of the supply air

    DEFF Research Database (Denmark)

    Gunnarsen, Lars; Santos, A M B

    2002-01-01

    air may facilitate personal cooling by increased evaporation of sweat. Heat acclimatized people with efficient sweating may in particular benefit from this cooling. A prototype solar powered supply system for dried-only air was made. Air from the system was mixed with room air, heated to six different...... content of room air, temperature of supply air and moisture content of supply air was developed based on the experiments. Reduction of moisture content in the supply air by 1.6 g/kg had the same effect as lowering the operative temperature by 1 degree C. The solar-powered system for supplying dry air...... is a low-cost alternative to traditional air conditioning in hot and humid regions....

  2. Use of multilevel modeling for determining optimal parameters of heat supply systems

    Science.gov (United States)

    Stennikov, V. A.; Barakhtenko, E. A.; Sokolov, D. V.

    2017-07-01

    The problem of finding optimal parameters of a heat-supply system (HSS) is in ensuring the required throughput capacity of a heat network by determining pipeline diameters and characteristics and location of pumping stations. Effective methods for solving this problem, i.e., the method of stepwise optimization based on the concept of dynamic programming and the method of multicircuit optimization, were proposed in the context of the hydraulic circuit theory developed at Melentiev Energy Systems Institute (Siberian Branch, Russian Academy of Sciences). These methods enable us to determine optimal parameters of various types of piping systems due to flexible adaptability of the calculation procedure to intricate nonlinear mathematical models describing features of used equipment items and methods of their construction and operation. The new and most significant results achieved in developing methodological support and software for finding optimal parameters of complex heat supply systems are presented: a new procedure for solving the problem based on multilevel decomposition of a heat network model that makes it possible to proceed from the initial problem to a set of interrelated, less cumbersome subproblems with reduced dimensionality; a new algorithm implementing the method of multicircuit optimization and focused on the calculation of a hierarchical model of a heat supply system; the SOSNA software system for determining optimum parameters of intricate heat-supply systems and implementing the developed methodological foundation. The proposed procedure and algorithm enable us to solve engineering problems of finding the optimal parameters of multicircuit heat supply systems having large (real) dimensionality, and are applied in solving urgent problems related to the optimal development and reconstruction of these systems. The developed methodological foundation and software can be used for designing heat supply systems in the Central and the Admiralty regions in

  3. Target study of heat supply from Northern Moravia nuclear power plant

    International Nuclear Information System (INIS)

    Pospisil, V.

    The construction is envisaged in Northern Moravia of a nuclear power plant near Blahutovice in the Novy Jicin district. Heat produced by the nuclear power plant will only be used for district heating; process heat will be supplied from local steam sources. An example is discussed of the Prerov locality which currently is supplied from the Prerov heating and power plant (230 MW), a heating plant (36 MW) and from local sources (15 NW). The study estimates that a thermal power of 430 MW will be required at a time of the start of heat supplies from the nuclear power plant. All heat supply pipelines will be designed as a two-tube system divided into sections with section pipe fittings. The number and location of pipe fittings will be selected depending on the terrain configuration. Water of the maximum outlet temperature of 150 degC will be used as a coolant. The control of the system for Northern Moravia is briefly described. (J.P.)

  4. Thermal Efficiency of Power Module “Boiler with Solar Collectors as Additional Heat Source” For Combined Heat Supply System

    Directory of Open Access Journals (Sweden)

    Denysova A.E.

    2015-04-01

    Full Text Available The purpose of work is to increase the efficiency of the combined heat supply system with solar collectors as additional thermal generators. In order to optimize the parameters of combined heat supply system the mathematical modeling of thermal processes in multi module solar collectors as additional thermal generators for preheating of the water for boiler have been done. The method of calculation of multi-module solar collectors working with forced circulation for various configurations of hydraulic connection of solar collector modules as the new result of our work have been proposed. The results of numerical simulation of thermal efficiency of solar heat source for boiler of combined heat supply system with the account of design features of the circuit; regime parameters of thermal generators that allow establishing rational conditions of its functioning have been worked out. The conditions of functioning that provide required temperature of heat carrier incoming to boiler and value of flow rate at which the slippage of heat carrier is not possible for different hydraulic circuits of solar modules have been established.

  5. Feasibility study on rehabilitation and improvement of thermal power plants, district heating and heat supply system in Botosani City

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Discussions have been given on the improvement and modification project intended of saving energies and reducing greenhouse gas emission in the Botosani district heating and heat supplying facilities in Romania. Thirty years have elapsed since the building of the Botosani district heating and heat supplying facilities, whereas noticeable energy loss has occurred due to aged deterioration, such as thermal efficiency decrease, performance decrease, and hot water leakage due to piping corrosion. The present project is intended to improve the heat production and power generation facility efficiencies, and reduce the heat loss in heat transportation and distribution to less than 5%. The improvements will be implemented by replacing and rehabilitating the existing boilers, replacing the turbine generators, and replacing the transportation and distribution pipelines and heat exchangers. As a result of the discussions, the present project is estimated to result in annual fuel conservation of 35,820 tons of crude oil equivalent, and annual reduction of the greenhouse gas emission of 110,835 t-CO2. The total amount of the initial investment for the project would be 11.369 billion yen, and the payback period would be 12 years. The project will produce profit of 31.358 billion yen in 20 years, thus the project is financially feasible. (NEDO)

  6. Resource recovery from municipal solid waste by mechanical heat treatment: An opportunity

    Science.gov (United States)

    Kamaruddin, Mohamad Anuar; Yusoff, Mohd Suffian; Ibrahim, Nurazim; Zawawi, Mohd Hafiz

    2017-04-01

    Municipal solid waste (MSW) stream in Malaysia consists of 50 to 60 % of food wastes. In general, food wastes are commingled in nature and very difficult to be managed in sustainable manner due to high moisture content. Consequently, by dumping food wastes together with inert wastes to the landfill as final disposal destination incurs large space area and reducing the lifespan of landfill. Therefore, certain fraction of the MSW as such; food wastes (FW) can be diverted from total disposal at the landfill that can improve landfill lifespan and environmental conservation. This study aims to determine the resource characteristics of FW extracted from USM cafeteria by means of mechanical heat treatment in the presence of autoclaving technology. Sampling of FW were conducted by collecting FW samples from disposal storage at designated area within USM campus. FW characteristics was performed prior and autoclaving process. The results have demonstrated that bones fraction was the highest followed by vegetable and rice with 39, 27 and 10%, respectively. Meanwhile, based on autoclaving technique, moisture content of the FW (fresh waste) were able to be reduced ranging from 65-85% to 59-69% (treated waste). Meanwhile, chemical characteristics of treated FW results in pH, TOC, TKN, C/N ratio, TP, and TK 5.12, 27,6%, 1.6%, 17.3%, 0.9% and 0.36%. The results revealed that autoclaving technology is a promising approach for MSW diversion that can be transformed into useful byproducts such as fertilizer, RDF and recyclable items.

  7. Local energy supply under national and European law. With special regard to municipal policy opportunities. Oertliche Energieversorgung nach nationalem und europaeischem Recht. Unter besonderer Beruecksichtigung kommunaler Gestaltungsmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Britz, G.

    1994-01-01

    Conceivably, the erection of a single European energy market for electricity and natural gas as specified in the EC draft guidelines may change the conditions of local energy supply. This thesis therefore investigates which instruments are at the disposal of municipal governments for the realization of energy-political concepts of their own: Rights of way and granting of franchises, establishment of and transfer of tasks to municipal utilities, common carvier duties, and free choice of suppliers by distributors. The handling of franchise payments and treatment of municipal interconnected networks are of considerable importance for the financial situation of communities. The first section deals with the legal issues of local energy supply with regard to national law. The second part deals with the same questions with regard to community law. Furthermore it is considered what would be the consequences of the realization of the two guidelines concerning the single energy market. In the final section the results are compared and the significance of community law for local energy supply is assessed. (orig./HP)

  8. Economic feasibility of heat supply from simple and safe nuclear plants

    International Nuclear Information System (INIS)

    Tian, J.

    2001-01-01

    Use of nuclear energy as a heating source is greatly challenged by the economic factor since the nuclear heating reactors have relative small size and often the lower plant load factor. However, use of very simple reactor could be a possible way to economically supply heat. A deep pool reactor (DPR) has been designed for this purpose. The DPR is a novel design of pool type reactor for heat only supply. The reactor core is put in a deep pool. By only putting light static water pressure on the core coolant, the DPR will be able to meet the temperature requirements of heat supply for district heating. The feature of simplicity and safety of DPR makes a decrease of investment cost compared to other reactors for heating only purposes. According to the economical assessments, the capital investment to build a DPR plant is much less than that of a pressurized reactor with pressure vessels. For the DPR with 120 or 200 MW output, it can bear the economical comparison with a usual coal-fired heating plant. Some special means taken in DPR design make an increase of the burn-up level of spent fuel and a decrease of fuel cost. The feasibility studies of DPR in some cities in China show that heating cost using nuclear energy is only one third of that by coal and only one tenth of that by nature gas. Therefore, the DPR nuclear heating system provides an economically attractive solution to satisfy the demands of district heating without contributing to increasing greenhouse gas emissions

  9. Experimental evaluation of radiator control based on primary supply temperature for district heating substations

    International Nuclear Information System (INIS)

    Gustafsson, Jonas; Delsing, Jerker; Deventer, Jan van

    2011-01-01

    Highlights: → We compared a new radiator system control approach with traditional control. → This is an experimental verification of previous simulation results. → We examine changes in delta-T and indoor comfort. → The indoor comfort were not affected by the introduction of alt. radiator control. → The alternative control method can contribute to an increased delta-T. -- Abstract: In this paper, we evaluate whether the primary supply temperature in district heating networks can be used to control radiator systems in buildings connected to district heating; with the purpose of increasing the ΔT. The primary supply temperature in district heating systems can mostly be described as a function of outdoor temperature; similarly, the radiator supply temperature in houses, offices and industries can also be described as a function of outdoor temperature. To calibrate the radiator control system to produce an ideally optimal radiator supply temperature that produces a maximized ΔT across the substation, the relationship between the primary supply temperature and outdoor temperature must be known. However, even if the relation is known there is always a deviation between the expected primary supply temperature and the actual temperature of the received distribution media. This deviation makes the radiator control system incapable of controlling the radiator supply temperature to a point that would generate a maximized ΔT. Published simulation results show that it is possible and advantageous to utilize the primary supply temperature for radiator system control. In this paper, the simulation results are experimentally verified through implementation of the control method in a real district heating substation. The primary supply temperature is measured by the heat-meter and is shared with the radiator control system; thus no additional temperature sensors were needed to perform the experiments. However additional meters were installed for surveillance purposes

  10. Environment-friendly heat supply with natural refrigerants. Large heat pumps use industrial waste heat and waste water; Umweltschonende Waermeversorgung mit natuerlichen Kaeltemitteln. Grosswaermepumpen nutzen industrielle Abwaerme und Abwaesser

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2011-01-15

    Everywhere, where industrial processes occur or coldness is produced, simultaneously heat is produced. While many private houses use geothermal energy or ambient air for the production of heat, waste water and waste heat prove to be optimal energy sources for the industrial need due to higher output temperatures. By means of large heat pumps the residual heat is used for heating or the supply of hot water for example in local heat supply grids and makes an important contribution to climate protection.

  11. Conceptual adsorption system of cooling and heating supplied by solar energy

    Directory of Open Access Journals (Sweden)

    Turski Michał

    2016-06-01

    Full Text Available This paper presents the possibility of reducing the demand for nonrenewable primary energy for buildings using a new conceptual adsorption system of cooling and heating supplied by solar energy. Moreover, the aim of this study is to shorten the payback time of investment in the standard adsorption cooling system through its integration with the heating system. Research has been carried out for an energy-efficient medium-sized single-family building with a floor area of 140 m2 and a heat load of 4.2 kW and cold load of 4.41 kW. It has been shown that the use of an adsorption system of cooling and heating supplied by solar energy decreased the demand for nonrenewable primary energy by about 66% compared to the standard building that meets the current requirements.

  12. Energy supply modelling of a low-CO 2 emitting energy system: Case study of a Danish municipality

    DEFF Research Database (Denmark)

    Sveinbjörnsson, Dadi Þorsteinn; Ben Amer-Allam, Sara; Hansen, Anders Bavnhøj

    2017-01-01

    Municipal activities play an important role in national and global CO2-emission reduction efforts, with Nordic countries at the forefront thanks to their energy planning tradition and high penetration of renewable energy sources. In this work, we present a case study of the Danish municipality...... dependent on changes in energy prices.We conclude that in order to achieve their CO2 emission goals in the most energy-efficient, cost-effective and sustainable way, municipalities similar to Sønderborg should compare a wide range of energy system configurations, for example, scenarios with a high degree...

  13. ENERGY-EFFICIENT REGIMES FOR HEATING-SUPPLY OF THE RESIDENTIAL BUILDINGS

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2015-01-01

    Full Text Available Rise in comfort and inhabitation safety is one of the main requirements of the general maintenance, reconstruction of the old and construction of the new residential houses. One of the essential factors of it is substitution in the household hot-water preparing sources: from the individual domestic gas  water-heaters to  the common  entire-building hot-water supply at the expense of the centralized heat supply. Extremely erratic hot-water daily consumption by tenants leads to the necessity of sharp increase in central heat-supply level during a few hours of the day, which requires a significant increase of the source heat-power. On that score, the authors propose to direct a significant part (up to 50 % of the centralized heating and ventilation heat power-consumption to the hot water preparation during the period of short-term hot water consumption peak.Substitution  of  the  individual  domestic  gas  water-heaters  with  the  common  entirebuilding hot-water supply releases a huge amount of natural gas which can be utilized not only for production of the necessary heat power but as well for electric power producing. This substitution is especially advantageous if heat-power is delivered to the residential area from a НРС where significant part of heat especially in a relatively warm season of the year is thrown out into the air. The content of the article is based on several patents received earlier.

  14. Setting technical and economic features regarding nuclear heating plants implementation for heat supply in Romania by the year 2010

    International Nuclear Information System (INIS)

    Romascu, G.; Constantin, L.; Gheorghe, A.; Ciocanescu, M.; Ionescu, M.

    2008-01-01

    This paper presents the world wide preoccupation concerning the implementation of nuclear heating plants for fulfilling the heat demand and the main technical data of the reactors destined to such NHP's. The second part of this paper shows technical and economic aspects related to the implementation of NHP's equipped with nuclear thermal reactor specialized in the exclusive heat supply in Romania at the level of the year 2010. Among these aspects the following are mentioned: - the results of researches and the world wide achievements; - the development and structure of the production and of the thermal electric energy as well as the feasibility for covering the demands for nuclear sources; - the impact on environment of various technologies for the production of thermal energy with conventional fuels comparing with NHP; - the philosophy from economic stand point for the covering part of the NHP heat demand. (authors)

  15. Balancing the organic load and light supply in symbiotic microalgal–bacterial biofilm reactors treating synthetic municipal wastewater

    NARCIS (Netherlands)

    Boelee, N.C.; Temmink, B.G.; Janssen, M.; Buisman, C.J.N.; Wijffels, R.H.

    2014-01-01

    Symbiotic microalgal–bacterial biofilms can be very attractive for municipal wastewater treatment. Microalgae remove nitrogen and phosphorus and simultaneously produce the oxygen that is required for the aerobic, heterotrophic degradation of organic pollutants. For the application of these biofilms

  16. Method for reducing excess heat supply experienced in typical Chinese district heating systems by achieving hydraulic balance and improving indoor air temperature control at the building level

    DEFF Research Database (Denmark)

    Zhang, Lipeng; Gudmundsson, Oddgeir; Thorsen, Jan Eric

    2016-01-01

    A common problem with Chinese district heating systems is that they supply more heat than the actual heat demand. The reason for this excess heat supply is the general failure to use control devices to adjust the indoor temperature and flow in the building heating systems in accordance with the a......A common problem with Chinese district heating systems is that they supply more heat than the actual heat demand. The reason for this excess heat supply is the general failure to use control devices to adjust the indoor temperature and flow in the building heating systems in accordance...... with the actual heat demand. This results in 15-30% of the total supplied heat being lost. This paper proposes an integrated approach that aims to reduce the excess heat loss by introducing pre-set thermostatic radiator valves combined with automatic balancing valves. Those devices establish hydraulic balance...... that once the hydraulic balance is achieved and indoor temperatures are controlled with this integrated approach, 17% heat savings and 42.8% pump electricity savings can be achieved. The energy savings will also have a positive environmental effect with seasonal reductions of 11 kg CO2, 0.1 kg SO2, and 0...

  17. An experimental study on defrosting heat supplies and energy consumptions during a reverse cycle defrost operation for an air source heat pump

    International Nuclear Information System (INIS)

    Dong Jiankai; Deng Shiming; Jiang Yiqiang; Xia Liang; Yao Yang

    2012-01-01

    For a space heating air source heat pump (ASHP) unit, when its outdoor coil surface temperature is below both the air dew point temperature and the freezing point of water, frost will form on its outdoor coil surface. Frosting affects its operational performance and energy efficiency. Therefore, periodic defrosting is necessary. Currently, the most widely used standard defrosting method for ASHP units is reverse cycle defrost. The energy that should have been used for space heating is used to melt frost, vaporize the melted frost off outdoor coil surface and heat ambient air during defrosting. It is therefore necessary to study the sources of heat supplies and the end-uses of the heat supplied during a reverse cycle defrost operation. In this paper, firstly, an experimental setup is described and experimental procedures are detailed. This is followed by reporting the experimental results and the evaluation of defrosting efficiency for the experimental ASHP unit. Finally, an evaluation of defrosting heat supplies and energy consumptions during a revere cycle defrost operation for the experimental ASHP unit is presented. The experimental and evaluation results indicated that the heat supply from indoor air contributed to 71.8% of the total heat supplied for defrosting and 59.4% of the supplied energy was used for melting frost. The maximum defrosting efficiency could be up to 60.1%. - Highlights: ► Heat supply and consumption during reverse cycle defrost was experimentally studied. ► Indoor air contributed to >70% of total heat supply when indoor fan was turned on. ► ∼60% of the supplied energy was used for melting frost. ► Alternate heat supply other than indoor air should be explored.

  18. Hybrid renewable energy system application for electricity and heat supply of a residential building

    Directory of Open Access Journals (Sweden)

    Nakomčić-Smaragdakis Branka B.

    2016-01-01

    Full Text Available Renewable and distributed energy systems could provide a solution to the burning issue of reliable and clean supply of energy, having in mind current state and future predictions for population growth and fossil fuel scarcity. Hybrid renewable energy systems are novelty in Serbia and warrant further detailed research. The aim of this paper is to analyze the application of renewable energy sources(RES for electricity and heat supply of a typical household in Serbia, as well as the cost-effectiveness of the proposed system. The influence of feed-in tariff change on the value of the investment is analyzed. Small, grid-connected hybrid system (for energy supply of a standard household, consisting of geothermal heat pump for heating/cooling, solar photovoltaic panels and small wind turbine for power supply is analyzed as a case study. System analysis was conducted with the help of RETScreen software. Results of techno-economics analysis have shown that investing in geothermal heat pump and photovoltaic panels is cost-effective, while that is not the case with small wind turbine.

  19. Fuel Application Efficiency in Ideal Cycle of Gas Turbine Plant with Isobaric Heat Supply

    Directory of Open Access Journals (Sweden)

    A. P. Nesenchuk

    2013-01-01

    Full Text Available The paper reveals expediency to use in prospect fuels with maximum value  Qнр∑Vi and minimum theoretical burning temperature in order to obtain maximum efficiency of the ideal cycle in GTP with isobaric heat supply.

  20. The optimization of heat supply centralization on the basis of boiler-rooms

    International Nuclear Information System (INIS)

    Arshakian, D.

    1992-01-01

    In this article the problem of finding of the optimum of heat supply centralization of towns and insutrial districts on the basis of boiler-rooms, using organic and nuclear fuel in the natural-climatic conditions and town-building transitions of Armenia is considered. (orig.) [de

  1. Reliability evaluation of power supply and distribution for special heat removal systems in nuclear power stations

    International Nuclear Information System (INIS)

    Jazbec, D.

    1982-01-01

    An example of the power supply and distribution of a Special Emergency Heat Removal System (SEHR) shows how an engineering organization may, with the aid of the analytical method of min-cut sets optimize the system reliability. Herein are given the necessary simple calculation methods. (Auth.)

  2. The participation of foreign supply companies in the promotion of solar heating systems

    International Nuclear Information System (INIS)

    Larsen, J.H.; Tveit, D.

    1995-06-01

    The extent of participation on the part of energy supply companies located in Germany, the Netherlands, Brazil and USA in the promotion of solar heating systems is investigated and various promotion projects carried out in these countries are described in detail. (AB)

  3. Active Power Flow Optimization of Industrial Power Supply with Regard to the Transmission Line Conductor Heating

    Directory of Open Access Journals (Sweden)

    Leyzgold D.Yu.

    2015-04-01

    Full Text Available This article studies the problem of the transmission line conductor heating effect on the active power flows optimization in the local segment of industrial power supply. The purpose is to determine the optimal generation rating of the distributed power sources, in which the power flow values will correspond to the minimum active power losses in the power supply. The timeliness is the need to define the most appropriate rated power values of distributed sources which will be connected to current industrial power supply. Basing on the model of active power flow optimization, authors formulate the description of the nonlinear transportation problem considering the active power losses depending on the transmission line conductor heating. Authors proposed a new approach to the heating model parameters definition based on allowable current loads and nominal parameters of conductors as part of the optimization problem. Analysis of study results showed that, despite the relatively small active power losses reduction to the tune 0,45% due to accounting of the conductors heating effect for the present configuration of power supply, there are significant fluctuations in the required generation rating in nodes of the network to 9,32% within seasonal changes in the outer air temperature. This fact should be taken into account when selecting the optimum power of distributed generation systems, as exemplified by an arbitrary network configuration.

  4. Heat supply analysis of steam reforming hydrogen production process in conventional and nuclear

    International Nuclear Information System (INIS)

    Siti Alimah; Djati Hoesen Salimy

    2015-01-01

    Tile analysis of heat energy supply in the production of hydrogen by natural gas steam reforming process has been done. The aim of the study is to compare the energy supply system of conventional and nuclear heat. Methodology used in this study is an assessment of literature and analysis based on the comparisons. The study shows that the heat sources of fossil fuels (natural gas) is able to provide optimum operating conditions of temperature and pressure of 850-900 °C and 2-3 MPa, as well as the heat transfer is dominated by radiation heat transfer, so that the heat flux that can be achieved on the catalyst tube relatively high (50-80 kW/m"2) and provide high thermal efficiency of about 85 %. While in the system with nuclear energy, due to the demands of safety, process operating at less than optimum conditions of temperature and pressure of 800-850 °C and 4.5 MPa, as well as the heat transfer is dominated by convection heat transfer, so that the heat flux that can be achieved catalyst tube is relatively low (1020 kW/m"2) and it provides a low thermal efficiency of about 50 %. Modifications of reformer and heat utilization can increase the heat flux up to 40 kW/m"2 so that the thermal efficiency can reach 78 %. Nevertheless, the application of nuclear energy to hydrogen production with steam reforming process is able to reduce the burning of fossil fuels which has implications for the potential decrease in the rate of CO2 emissions into the environment. (author)

  5. Electricity supply, district heating and supply of natural and gasworks gas 1999

    International Nuclear Information System (INIS)

    2001-01-01

    Total domestic use of electricity (including transmission losses) was 143.3 TWh in 1999. This represents a decrease of 0.5 per cent compared to 1998. Usage in the household sector fell by 1.5 per cent to 34.3 TWh (including second homes). In contrast, the industry sector (manufacturing industry, mining and quarrying) increased its usage by 1.1 per cent to 55.3 TWh. Deliveries of steam and hot water for district heating were 43.7 TWh, unchanged compared to 1998. Total net production of electricity decreased in 1999 by 2.5 per cent compared to 1998 and amounted to 150.8 TWh. Hydroelectric production decreased by 4.0 per cent to 70.9 TWh. The production of conventional thermal power also fell, by 5.6 per cent to 9.4 TWh. Nuclear power contributed 70.2 TWh, almost the same as the previous year. Wind power, however, increased its production by 16.2 per cent to 358 GWh. Imports of electricity increased by 0.4 TWh to 8.5 TWh, but exports decreased by 0.9 TWh to 15.9 TWh. Total deliveries of natural gas to final consumers diminished somewhat in 1999 and amounted to 854 million m 3 (equivalent to 9226 GWh). Deliveries of natural gas substitutes (air/liquefied petroleum gas mix) decreased by 5 per cent to 26 million m 3 . The mean price of natural gas rose by approximately 6 per cent compared to 1998. Deliveries of gas-works gas fell in 1999 by 0.6 million m 3 to 109.2 million m 3 . The mean price was about 11 per cent higher than in the preceding year

  6. Development of hot water supply system for a small district heating reactor

    International Nuclear Information System (INIS)

    Murase, Toshihiko; Narabayashi, Tadashi; Shimazu, Yoichiro

    2007-01-01

    On the earth, there are many environmental problems. For example, rapid increase of world population causes the enormous consumption of fossil fuel and emission of CO 2 into the global air. Now, mankaind faced to deal with these serious problems. One solution for these problems is utilization of nuclear reactors. Currently, about 65% of thermal output of a nuclear reactor is thrown away to the sea or the atmosphere through a turbine condenser. When a hot-water pipeline from a nuclear plant will be constructed, the exhaust heat from nuclear reactor will able to be utilized. Therefore, authors began to study nuclear power plant system for district heating. This reactor is based on a PWR plant. Its thermal output is 10 MWth and its electrical output is 3.4 MW. The nuclear plant supply electricity and heat for 2000 to 3000 houses. The plant aim to supply all the energy for the adjacent pepole's life, for example, heat, electricity and hydrogen for fuel battery car. This total-energy supply system assumed to be built in Northern area such as Hokkaido in Japan. In order to develop an optimum thermal design method for the system, heat transport experiments and thermal-hydraulic calculations were carried out. Using a metal pipe covered with foam-polyurethane thermal insulator, feed-water temperature and return-water temperature was measured to evaluate heat loss. As the result, the heat loss from the hot-water temperature was very little. The thermal-hydraulic calculation method was verified and applied to actual pipeline size calculation. The result of heat loss calculation will be 0.2degC/5 km. considering these results, the best pipe specification was obtained. (author)

  7. Identifying the optimal supply temperature in district heating networks - A modelling approach

    DEFF Research Database (Denmark)

    Mohammadi, Soma; Bojesen, Carsten

    2014-01-01

    of this study is to develop a model for thermo-hydraulic calculation of low temperature DH system. The modelling is performed with emphasis on transient heat transfer in pipe networks. The pseudo-dynamic approach is adopted to model the District Heating Network [DHN] behaviour which estimates the temperature...... dynamically while the flow and pressure are calculated on the basis of steady state conditions. The implicit finite element method is applied to simulate the transient temperature behaviour in the network. Pipe network heat losses, pressure drop in the network and return temperature to the plant...... are calculated in the developed model. The model will serve eventually as a basis to find out the optimal supply temperature in an existing DHN in later work. The modelling results are used as decision support for existing DHN; proposing possible modifications to operate at optimal supply temperature....

  8. The occurrence of Aeromonas spp. in the bottled mineral water, well water and tap water from the municipal supplies

    Directory of Open Access Journals (Sweden)

    Denise de Oliveira Scoaris

    2008-10-01

    Full Text Available The aim of this work was to study the occurrence of Aeromonas sp in the bottled mineral water, well water and tap water from the municipal supplies. Positive samples were found for Aeromonas spp. 12.7% from the mineral water, 8.3% from the artesian water and 6.5% from the tap water. The recovery of Aeromonas spp. was significantly higher in the bottled mineral and artesian water than in the tap water from municipal supplies. The occurrence of the Aeromonas spp. did not correlate significantly with the contamination indicator bacteria (i.e. total coliforms in the artesian water samples. However, a significant correlation was found between Aeromonas spp. and total coliforms in the both mineral water and tap water samples. The presence or absence of a correlation between the indicator bacteria and Aeromonas could reflect the occasional appearance of the pathogen in the drinking water and the different rates of survival and recovery of these agents compared with those fecal indicators. The finding that 41.6, 14.8 and 9.0 % of the artesian water, bottled mineral water and tap water, respectively, sampled in the current study failed to meet the Brazilian standard for total coliforms in the drinking water should therefore be of concern.A porcentagem de amostras positivas para Aeromonas foi de 12.7% para água mineral, 8.3% para água de poço artesiano e 6.5% para água do sistema público de abastecimento. O isolamento de Aeromonas spp. foi significativamente maior em água mineral e água de poço artesiano do que em água do sistema público. A ocorrência de Aeromonas spp. não teve correlação significativa com os indicadores de contaminação tradicionalmente utilizados (coliformes totais em amostras de água de poço artesiano. No entanto, esta correlação foi positiva e significativa em água mineral e água do sistema público. A presença ou ausência de correlação entre bactérias indicadoras e a presença de Aeromonas pode refletir o

  9. Equipment sizing in a coal-fired municipal heating plant modernisation project with support for renewable energy and cogeneration technologies

    International Nuclear Information System (INIS)

    Kalina, Jacek

    2014-01-01

    Highlights: • Sizing of biomass fired cogeneration block is performed for existing heating plant. • Mathematical model for cogeneration block optimisation is presented. • Impact of financial support mechanisms on optimal solution is discussed. • Influence of short term variations of prices and support intensity is presented. • Different design parameters are suggested by economic and technical quality indices. - Abstract: The paper presents results of design parameters optimisation of a wood chips fired steam boiler based heat and power block in a sample project of coal fired municipal heating plant modernisation. The project assumes the conversion of the heating plant into a dual fuel heat and power plant. The problem that is presented is selection of cogeneration block structure and thermodynamic parameters taking into account financial support mechanisms for cogeneration and renewable energy technologies. There are examined energy conversion and financial performances of the project. The results show that without the financial support the project is not profitable although it generates savings of primary energy of fossil fuels. If an administrative incentives are applied the optimal technical solution is different than suggested by energy conversion efficiency or fossil fuel savings. Financial calculations were performed for Polish marked conditions in the years 2011 and 2014 showing the impact of relatively short term variations of prices and support intensity on optimal plant design parameters

  10. Electricity and combined heat and power from municipal solid waste; theoretically optimal investment decision time and emissions trading implications.

    Science.gov (United States)

    Tolis, Athanasios; Rentizelas, Athanasios; Aravossis, Konstantin; Tatsiopoulos, Ilias

    2010-11-01

    Waste management has become a great social concern for modern societies. Landfill emissions have been identified among the major contributors of global warming and climate changes with significant impact in national economies. The energy industry constitutes an additional greenhouse gas emitter, while at the same time it is characterized by significant costs and uncertain fuel prices. The above implications have triggered different policies and measures worldwide to address the management of municipal solid wastes on the one hand and the impacts from energy production on the other. Emerging methods of energy recovery from waste may address both concerns simultaneously. In this work a comparative study of co-generation investments based on municipal solid waste is presented, focusing on the evolution of their economical performance over time. A real-options algorithm has been adopted investigating different options of energy recovery from waste: incineration, gasification and landfill biogas exploitation. The financial contributors are identified and the impact of greenhouse gas trading is analysed in terms of financial yields, considering landfilling as the baseline scenario. The results indicate an advantage of combined heat and power over solely electricity production. Gasification, has failed in some European installations. Incineration on the other hand, proves to be more attractive than the competing alternatives, mainly due to its higher power production efficiency, lower investment costs and lower emission rates. Although these characteristics may not drastically change over time, either immediate or irreversible investment decisions might be reconsidered under the current selling prices of heat, power and CO(2) allowances.

  11. Design of a low temperature district heating network with supply recirculation

    DEFF Research Database (Denmark)

    Li, Hongwei; Dalla Rosa, Alessandro; Svendsen, Svend

    2010-01-01

    The focus on continuing improving building energy efficiency and reducing building energy consumption brings the key impetus for the development of the new generation district heating (DH) system. In the new generation DH network, the supply and return temperature are designed low in order to sig...... calculates the heat loss in the twin pipe as that in the single pipe. The influence of this simplification on the supply/return water temperature prediction was analyzed by solving the coupled differential energy equations.......-pass system starts to function. The aim of this paper is to investigate the influence of by-pass water on the network return temperature and introduce the concept of supply water recirculation into the network design so that the traditional by-pass system can be avoided. Instead of mixing the by-pass water......The focus on continuing improving building energy efficiency and reducing building energy consumption brings the key impetus for the development of the new generation district heating (DH) system. In the new generation DH network, the supply and return temperature are designed low in order...

  12. Dual Rate Adaptive Control for an Industrial Heat Supply Process Using Signal Compensation Approach

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Tianyou; Jia, Yao; Wang, Hong; Su, Chun-Yi

    2017-07-09

    The industrial heat supply process (HSP) is a highly nonlinear cascaded process which uses a steam valve opening as its control input, the steam flow-rate as its inner loop output and the supply water temperature as its outer loop output. The relationship between the heat exchange rate and the model parameters, such as steam density, entropy, and fouling correction factor and heat exchange efficiency are unknown and nonlinear. Moreover, these model parameters vary in line with steam pressure, ambient temperature and the residuals caused by the quality variations of the circulation water. When the steam pressure and the ambient temperature are of high values and are subjected to frequent external random disturbances, the supply water temperature and the steam flow-rate would interact with each other and fluctuate a lot. This is also true when the process exhibits unknown characteristic variations of the process dynamics caused by the unexpected changes of the heat exchange residuals. As a result, it is difficult to control the supply water temperature and the rates of changes of steam flow-rate well inside their targeted ranges. In this paper, a novel compensation signal based dual rate adaptive controller is developed by representing the unknown variations of dynamics as unmodeled dynamics. In the proposed controller design, such a compensation signal is constructed and added onto the control signal obtained from the linear deterministic model based feedback control design. Such a compensation signal aims at eliminating the unmodeled dynamics and the rate of changes of the currently sample unmodeled dynamics. A successful industrial application is carried out, where it has been shown that both the supply water temperature and the rate of the changes of the steam flow-rate can be controlled well inside their targeted ranges when the process is subjected to unknown variations of its dynamics.

  13. Solar-heated municipal swimming pools, a case study: Dade County, Florida

    Science.gov (United States)

    Levin, M.

    1981-09-01

    The installation of a solar energy system to heat the water in the swimming pool in one of Dade County, Florida's major parks is described. The mechanics of solar heated swimming pools are explained. The solar heating system consists of 216 unglazed polypropylene tube collectors, a differential thermostat, and the distribution system. The systems performance and economics as well as future plants are discussed.

  14. Modelling and multi-scenario analysis for electric heat tracing system combined with low temperature district heating for domestic hot water supply

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    Low temperature district heating (LTDH) is a cost-efficient way of supplying space heating and domestic hot water (DHW) for buildings in urban areas. However, there is concern that the potential hygiene problems (Legionella) might occur if LTDH is implemented, especially for large buildings...... performance on heat loss saving, and it also gave benefits to district heating network by sharing part of the heating load....

  15. Multicriteria optimization approach to design and operation of district heating supply system over its life cycle

    Science.gov (United States)

    Hirsch, Piotr; Duzinkiewicz, Kazimierz; Grochowski, Michał

    2017-11-01

    District Heating (DH) systems are commonly supplied using local heat sources. Nowadays, modern insulation materials allow for effective and economically viable heat transportation over long distances (over 20 km). In the paper a method for optimized selection of design and operating parameters of long distance Heat Transportation System (HTS) is proposed. The method allows for evaluation of feasibility and effectivity of heat transportation from the considered heat sources. The optimized selection is formulated as multicriteria decision-making problem. The constraints for this problem include a static HTS model, allowing considerations of system life cycle, time variability and spatial topology. Thereby, variation of heat demand and ground temperature within the DH area, insulation and pipe aging and/or terrain elevation profile are taken into account in the decision-making process. The HTS construction costs, pumping power, and heat losses are considered as objective functions. Inner pipe diameter, insulation thickness, temperatures and pumping stations locations are optimized during the decision-making process. Moreover, the variants of pipe-laying e.g. one pipeline with the larger diameter or two with the smaller might be considered during the optimization. The analyzed optimization problem is multicriteria, hybrid and nonlinear. Because of such problem properties, the genetic solver was applied.

  16. Analysis of an effective solution to excessive heat supply in a city primary heating network using gas-fired boilers for peak-load compensation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hai-Chao; Jiao, Wen-Ling; Zou, Ping-Hua; Liu, Jing-Cheng [School of Municipal and Environmental Engineering, Harbin Institute of Technology, mail box 2645, 202 Haihe Road, Nangang District, Harbin 150090 (China)

    2010-11-15

    Through investigation of the Dengfeng heating network in the city of Daqing, China, for the 2007-2008 heating season, we found serious problems of excessive heat supply in the primary heating network. Therefore, we propose the application of gas-fired boilers in underperforming heating substations as peak-load heat sources to effectively adapt to the regulation demands of seasonal heat-load fluctuations and reduce the excessive heat supply. First, we calculated the excessive heat supply rates (EHSRs) of five substations using detailed investigative data. We then discussed the feasibility of the proposed scheme providing energy savings from both energetic and exergetic points of view. The results showed that the average EHSR of the five substations between January and March was 20.57% of the gross heat production but consequently reduced to 6.24% with the installation of the gas-fired boilers. Therefore, the combined heating scheme with coal as the basic heat-source and gas-fired boilers as peak-load heat sources is energy-efficient to some extent, although requires the use of natural gas. Meanwhile, the exergy decreased by 10.97%, which indicates that the combined heating scheme effectively reduces the primary energy consumption and pollutant emission of the heating systems. (author)

  17. Urban forests' potential to supply marketable carbon emission offsets: a survey of municipal governments in the United States

    Science.gov (United States)

    Neelam C. Poudyal; Jacek P. Siry; J. M. Bowker

    2010-01-01

    This study assesses the motivation, willingness, and technical as well as managerial capacities of U.S. cities to store carbon and sell carbon offsets. Based on a national survey of urban foresters, arborists, and other officials responsible for urban forest management within U.S. municipal governments, results indicate that local governments are interested in selling...

  18. Strengths and weaknesses in the supply of school food resulting from the procurement of family farm produce in a municipality in Brazil.

    Science.gov (United States)

    Soares, Panmela; Martinelli, Suellen Secchi; Melgarejo, Leonardo; Davó-Blanes, Mari Carmen; Cavalli, Suzi Barletto

    2015-06-01

    The objective of this study was to assess compliance with school food programme recommendations for the procurement of family farm produce. This study consists of an exploratory descriptive study utilising a qualitative approach based on semistructured interviews with key informants in a municipality in the State of Santa Catarina in Brazil. Study participants were managers and staff of the school food programme and department of agriculture, and representatives of a farmers' organisation. The produce delivery and demand fulfilment stages of the procurement process were carried out in accordance with the recommendations. However, nonconformities occurred in the elaboration of the public call for proposals, elaboration of the sales proposal, and fulfilment of produce quality standards. It was observed that having a diverse range of suppliers and the exchange of produce by the cooperative with neighbouring municipalities helped to maintain a regular supply of produce. The elaboration of menus contributed to planning agricultural production. However, agricultural production was not mapped before elaborating the menus in this case study and an agricultural reform settlement was left out of the programme. A number of weaknesses in the programme were identified which need to be overcome in order to promote local family farming and improve the quality of school food in the municipality.

  19. Electricity supply, district heating and supply of natural and gasworks gas 2011; El-, gas- och fjaerrvaermefoersoerjningen 2011

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-02-15

    Decline in electricity use: The final consumption of electricity in the country (excluding losses) amounted in 2011 to 130.6 TWh. It meant a decline of 3.4 percent compared with the year before. The industry's use grew by 0.9 percent to 53.8 TWh. Household use (permanent housing and second homes) declined to 33.7 TWh (-9.6 percent). While other application within the service sector and public administration declined to 43.0 TWh (-3.2 percent). Increase in electricity generation: Electricity generation increased in 2011. Net production increased by 1.8 percent to 147.5 TWh, compared with the previous year. The largest increase observed for wind power, which rose by 74.2 percent to 6.1 TWh. Water power was virtually unchanged (66.7 TWh). The conventional thermal power dropped to 16.8 TWh, a decline of 11.9 percent. Nuclear power increased by 4.3 percent to 58.0 TWh. Power exchanges with foreign countries gave in 2011 a surplus of 7.2 TWh. Reduced heating supplies: Deliveries of heat to the final use declined in 2011. Delivered-na totaled 48.1 TWh, which represents a decrease of 16.1 percent compared with the year before.

  20. Integration of biomass fast pyrolysis and precedent feedstock steam drying with a municipal combined heat and power plant

    International Nuclear Information System (INIS)

    Kohl, Thomas; Laukkanen, Timo P.; Järvinen, Mika P.

    2014-01-01

    Biomass fast pyrolysis (BFP) is a promising pre-treatment technology for converting biomass to transport fuel and in the future also for high-grade chemicals. BFP can be integrated with a municipal combined heat and power (CHP) plant. This paper shows the influence of BFP integration on a CHP plant's main parameters and its effect on the energetic and environmental performance of the connected district heating network. The work comprises full- and part-load operation of a CHP plant integrated with BFP and steam drying. It also evaluates different usage alternatives for the BFP products (char and oil). The results show that the integration is possible and strongly beneficial regarding energetic and environmental performance. Offering the possibility to provide lower district heating loads, the operation hours of the plant can be increased by up to 57%. The BFP products should be sold rather than applied for internal use as this increases the district heating network's primary energy efficiency the most. With this integration strategy future CHP plants can provide valuable products at high efficiency and also can help to mitigate global CO 2 emissions. - Highlights: • Part load simulation of a cogeneration plant integrated with biomas fast pyrolysis. • Analysis of energetic and environmental performance. • Assessment of different uses of the pyrolysis products

  1. Upscaling a district heating system based on biogas cogeneration and heat pumps

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; de Wit, Jan B.

    2015-01-01

    The energy supply of the Meppel district Nieuwveense landen is based on biogas cogeneration, district heating, and ground source heat pumps. A centrally located combined heat and power engine (CHP) converts biogas from the municipal wastewater treatment facility into electricity for heat pumps and

  2. Gas engine driven freon-free heat supply system complying with multiple fuels (eco-energy city project)

    Energy Technology Data Exchange (ETDEWEB)

    Yagyu, Sumio; Maekawa, Koich; Sugawara, Koich; Hayashida, Masaru; Fujishima, Ichiro; Fukuyama, Yuji; Morikawa, Tomoyuki; Yamato, Tadao; Obata, Norio [Advanced Technology Lab., Kubota Corp., Amagasaki, Hyogo (Japan)

    1999-07-01

    This paper describes recent results at Kubota to develop a gas engine driven freon-free heat supply system. Utilizing a gas mixture which consists of CO and H{sub 2} supplied from a broad area energy utilization network, the system produces four heat sources (263 K, 280 K, 318 K, and 353 K) for air-conditioning, hot water supply, and refrigeration in a single system. It also conforms to fuel systems that utilize methane and hydrogen. This multi-functional heat supply system is composed of an efficient gas engine (methanol gas engine) and a freon-free heat pump (heat-assisted Stirling heat pump). The heat-assisted Stirling heat pump is mainly driven by engine shaft power and is partially assisted by thermal power provided by engine exhaust heat. By proportioning the two energy sources to match the characteristics of the driving engine, the heat pump is supplied with the maximum share of the original energy fueling the engine. Developing the system will establish freon-free thermal utilization system technology that satisfies both wide heat demands and various fuel systems. (orig.)

  3. Solar-Biomass hybrid system for process heat supply in medium scale hotels in Sri Lanka

    OpenAIRE

    Abeywardana, Asela M.A.J.

    2016-01-01

    This study aimed at evaluating and demonstrating the feasibility of using Concentrated Solar Thermal technology combined with biomass energy technology as a hybrid renewable energy system to supply the process heat requirements in small scale industries in Sri Lanka. Particularly, the focus was to apply the concept to the expanding hotel industry, for covering the thermal energy demand of a medium scale hotel. Solar modules utilize the rooftop area of the building to a valuable application. L...

  4. AUTONOMOUS HEAT SUPPLY SYSTEM OF CONSUMERS WITH CONSIDERABLE DIFFERENT THERMAL INERTIA

    Directory of Open Access Journals (Sweden)

    Berzan V.P.

    2012-04-01

    Full Text Available There are examined problems occurring at the adoption of the decentralized heat energy supply system of the group of objects, which contains buildings with thermal inertia differed in thousands of times one from the other. It is studied the influence of water volume of hot-water boiler on greenhouse dynamics. It is conducted the comparison between the use ob biomass and natural gas boilers for such as objects.

  5. Advanced marine reactor MRX and application to nuclear barge supplying electricity and heat

    International Nuclear Information System (INIS)

    Ishida, Toshihisa; Kusunoki, Tsuyoshi; Odano, Naoteru; Yoritsune, Tsutomu; Fukuhara, Yoshifumi; Ochiai, Masa-aki

    2000-01-01

    The basic design concept of an advanced marine reactor MRX has been established with adoption of several new technologies. The MRX is an integral-type PWR with 100 MWt aimed basically for use of ship propulsion. Adoption of a water-filled containment together with the integral type reactor makes the reactor light-weight and compact greatly. A engineered safety system is a simplified passive system, function of which is confirmed by the safety analysis. The MRX can be applied to an energy supply system of electricity and heat co-generation by installing it on a barge. Concept of a nuclear barge with the MRX of 334 MWt output is presented for use of supplying electricity, fresh water and hot water. Combined system of electric generation and desalination with the RO process can deliver variable output of electricity and fresh water according a demand. Latent heat of the exhausted steam from the turbine can be used effectively to raise the temperature of cold water as heat supply. (author)

  6. Bio energy heating plant heats municipal buildings in Nord-Odal; Bioenergisentral varmer kommunale bygg i Nord-Odal

    Energy Technology Data Exchange (ETDEWEB)

    2008-07-01

    When Nord-Odal planned to build a new nursing home, they wanted to find a more environmental friendly heating system than based on oil and electricity. Several energy consultants evaluated the task. But when all consultants concluded there would be no cost benefit in this task, local experts looked into it - and because they got a long term agreement, it was possible to finance a local bio energy heat plant. (AG)

  7. Partial costs of global climate change adaptation for the supply of raw industrial and municipal water: a methodology and application

    NARCIS (Netherlands)

    Ward, P.J.; Strzepek, K.; Pauw, W.P.; Brander, L.M.; Hughes, G.; Aerts, J.C.J.M.

    2010-01-01

    Despite growing recognition of the importance of climate change adaptation, few global estimates of the costs involved are available for the water supply sector. We present a methodology for estimating partial global and regional adaptation costs for raw industrial and domestic water supply, for a

  8. The situation of district heating, district cooling and energy supply in Hungary

    International Nuclear Information System (INIS)

    Sigmond, Gy.

    2009-01-01

    District heating represents with 650.000 heated dwellings approximately 15% of the Hungarian residential heating market. Since 1990 there is stagnation at the number of connected dwellings because erection of large settlements with prefab buildings has been stopped, and latter ones represent more than 75% of the dwelling heating market. During the same period, residential heat demand shrunk by 33%, because metering of hot water consumption resulted in changing consumer habits, and because of slowly but step by step refurbishment of buildings and heating systems. In Hungary district heating is present in all large and most of the medium size cities, in 92 cities together. Out of them, there is also a single village with a local district heating system, which heats more than 60% of cottages. The capacity os systems is spreading to a large extent. Approximately 36-36% of all heated dwellings are in Budapest and in 10 large cities in the country, while 148 of the total 202 systems have less than 10 MW capacities. In the fuel structure of district heating it is characteristic the overwhelming role of natural gas consumption, which has exceeded 80% already. Only a few numbers of heating power plants are fuelled by crown coal. The use of renewables is growing continuous, but, together with waste and waste energy, it amounts merely 8% of the total fuel use. Oil consumption is negligible. Currently the most promising DH-market is the service sector (public buildings and commercial consumers). DH-companies can sell their surplus supply capacities on the competitive market. Residential market can be preserved only with better legal conditions and with improving of demand side management. The industrial heat market can be gained when the erection of new power plants will be harmonized with industrial development in the frame of territorial planning. District cooling is just at the beginning in Hungary. Many new commercial and office buildings are erected with air conditioning

  9. Effect of materials mixture on the higher heating value: Case of biomass, biochar and municipal solid waste.

    Science.gov (United States)

    Boumanchar, Imane; Chhiti, Younes; M'hamdi Alaoui, Fatima Ezzahrae; El Ouinani, Amal; Sahibed-Dine, Abdelaziz; Bentiss, Fouad; Jama, Charafeddine; Bensitel, Mohammed

    2017-03-01

    The heating value describes the energy content of any fuel. In this study, this parameter was evaluated for different abundant materials in Morocco (two types of biochar, plastic, synthetic rubber, and cardboard as municipal solid waste (MSW), and various types of biomass). Before the evaluation of their higher heating value (HHV) by a calorimeter device, the thermal behavior of these materials was investigated using thermogravimetric (TGA) and Differential scanning calorimetry (DSC) analyses. The focus of this work is to evaluate the calorific value of each material alone in a first time, then to compare the experimental and theoretical HHV of their mixtures in a second time. The heating value of lignocellulosic materials was between 12.16 and 20.53MJ/kg, 27.39 for biochar 1, 32.60MJ/kg for biochar 2, 37.81 and 38.00MJ/kg for plastic and synthetic rubber respectively and 13.81MJ/kg for cardboard. A significant difference was observed between the measured and estimated HHVs of mixtures. Experimentally, results for a large variety of mixture between biomass/biochar and biomass/MSW have shown that the interaction between biomass and other compounds expressed a synergy of 2.37% for biochar 1 and 6.11% for biochar 2, 1.09% for cardboard, 5.09% for plastic and 5.01% for synthetic rubber. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Characteristic performance of radio-frequency(RF) plasma heating using inverter RF power supplies

    International Nuclear Information System (INIS)

    Imai, Takahiro; Uesugi, Yoshihiko; Takamura, Shuichi; Sawada, Hiroyuki; Hattori, Norifumi

    2000-01-01

    High heat flux plasma are produced by high powe (∼14 kW) ICRF heating using inverter power supplies in the linear divertor simulator NAGDIS-II. The power flow of radiated rf power is investigated by a calorimetric method. Conventional power calculation using antenna voltage and current gives that about 70% of the rf power is radiated into the plasma. But increase of the heat load at the target and anode is about 10% of the rf power. Through this experiment, we find that about half of the rf power is lost at the antenna surface through the formation of rf induced sheath. And about 30% of the power is lost into the vacuum vessel through the charge exchange and elastic collision of ions with neutrals. (author)

  11. Method for reducing excess heat supply experienced in typical Chinese district heating systems by achieving hydraulic balance and improving indoor air temperature control at the building level

    International Nuclear Information System (INIS)

    Zhang, Lipeng; Gudmundsson, Oddgeir; Thorsen, Jan Eric; Li, Hongwei; Li, Xiaopeng; Svendsen, Svend

    2016-01-01

    A common problem with Chinese district heating systems is that they supply more heat than the actual heat demand. The reason for this excess heat supply is the general failure to use control devices to adjust the indoor temperature and flow in the building heating systems in accordance with the actual heat demand. This results in 15–30% of the total supplied heat being lost. This paper proposes an integrated approach that aims to reduce the excess heat loss by introducing pre-set thermostatic radiator valves combined with automatic balancing valves. Those devices establish hydraulic balance, and stabilize indoor temperatures. The feasibility and the energy consumption reduction of this approach were verified by means of simulation and a field test. By moving the system from centrally planned heat delivery to demand-driven heat delivery, excess heat loss can be significantly reduced. Results show that once the hydraulic balance is achieved and indoor temperatures are controlled with this integrated approach, 17% heat savings and 42.8% pump electricity savings can be achieved. The energy savings will also have a positive environmental effect with seasonal reductions of 11 kg CO_2, 0.1 kg SO_2, and 0.03 kg NO_x per heating square meter for a typical case in Harbin. - Highlights: • Two real cases reflect the temperature and flow control situation of heating systems in China. • Pre-set radiator valves with automatic balancing valves create dynamic hydraulic balance. • IDA-ICE simulation shows 17% heat saving and 48% pump electricity saving. • This approach can improve the comfort level of multi-storey/high-rise residential buildings. • This approach can reduce excess heat supply and bring out positive environmental impacts.

  12. The composition, heating value and renewable share of the energy content of mixed municipal solid waste in Finland

    International Nuclear Information System (INIS)

    Horttanainen, M.; Teirasvuo, N.; Kapustina, V.; Hupponen, M.; Luoranen, M.

    2013-01-01

    Highlights: • New experimental data of mixed MSW properties in a Finnish case region. • The share of renewable energy of mixed MSW. • The results were compared with earlier international studies. • The average share of renewable energy was 30% and the average LHVar 19 MJ/kg. • Well operating source separation decreases the renewable energy content of MSW. - Abstract: For the estimation of greenhouse gas emissions from waste incineration it is essential to know the share of the renewable energy content of the combusted waste. The composition and heating value information is generally available, but the renewable energy share or heating values of different fractions of waste have rarely been determined. In this study, data from Finnish studies concerning the composition and energy content of mixed MSW were collected, new experimental data on the compositions, heating values and renewable share of energy were presented and the results were compared to the estimations concluded from earlier international studies. In the town of Lappeenranta in south-eastern Finland, the share of renewable energy ranged between 25% and 34% in the energy content tests implemented for two sample trucks. The heating values of the waste and fractions of plastic waste were high in the samples compared to the earlier studies in Finland. These high values were caused by good source separation and led to a low share of renewable energy content in the waste. The results showed that in mixed municipal solid waste the renewable share of the energy content can be significantly lower than the general assumptions (50–60%) when the source separation of organic waste, paper and cardboard is carried out successfully. The number of samples was however small for making extensive conclusions on the results concerning the heating values and renewable share of energy and additional research is needed for this purpose

  13. The composition, heating value and renewable share of the energy content of mixed municipal solid waste in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Horttanainen, M., E-mail: mika.horttanainen@lut.fi; Teirasvuo, N.; Kapustina, V.; Hupponen, M.; Luoranen, M.

    2013-12-15

    Highlights: • New experimental data of mixed MSW properties in a Finnish case region. • The share of renewable energy of mixed MSW. • The results were compared with earlier international studies. • The average share of renewable energy was 30% and the average LHVar 19 MJ/kg. • Well operating source separation decreases the renewable energy content of MSW. - Abstract: For the estimation of greenhouse gas emissions from waste incineration it is essential to know the share of the renewable energy content of the combusted waste. The composition and heating value information is generally available, but the renewable energy share or heating values of different fractions of waste have rarely been determined. In this study, data from Finnish studies concerning the composition and energy content of mixed MSW were collected, new experimental data on the compositions, heating values and renewable share of energy were presented and the results were compared to the estimations concluded from earlier international studies. In the town of Lappeenranta in south-eastern Finland, the share of renewable energy ranged between 25% and 34% in the energy content tests implemented for two sample trucks. The heating values of the waste and fractions of plastic waste were high in the samples compared to the earlier studies in Finland. These high values were caused by good source separation and led to a low share of renewable energy content in the waste. The results showed that in mixed municipal solid waste the renewable share of the energy content can be significantly lower than the general assumptions (50–60%) when the source separation of organic waste, paper and cardboard is carried out successfully. The number of samples was however small for making extensive conclusions on the results concerning the heating values and renewable share of energy and additional research is needed for this purpose.

  14. Feasibility improvement project of a district heat supply system in Dalian, China

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Investigations and discussions have been given on energy saving possibilities at two medium-sized heat and power supplying plants in the city of Dalian in China. The project will improve the operation methods of the heat and power plants so that the energy cost can be minimized, and attempt to improve the boiler heat efficiency and save the energy by means of heat recovery and utilization. The draft modification plan for energy conservation has planned operation optimization for energy conservation, control of boiler operation under variable pressure, modification of the external boiler heat converter, use of inverters for the large capacity motors for boilers, and recovery of heat from the boiler blow-down water. In the analysis, models were structured from the operation data, and the effects of applying the energy saving measures were derived from simulation. As a result, the energy saving effect was found to be about 13,000 tons at the Chunhai plant and about 7,000 tons at the Pulandian plant annually (converted to oil). The reduction in greenhouse gas emission was found to be about 40,000 tons at the Chunhai plant and about 20,000 tons at the Pulandian plant annually. The number of years for investment payback is about 4.1 years at the Chunhai plant, and about 4.9 years at the Pulandian plant, wherein good profitability can be estimated. (NEDO)

  15. Application of ground-to-air heat exchanger for preheating of supply air

    Science.gov (United States)

    Sorokins, Juris; Borodinecs, Anatolijs; Zemitis, Jurgis

    2017-10-01

    This study focuses on assessing the contribution of the passive ground-coupled air heat exchanger system to decreasing the energy consumption of air conditioning and ventilation systems for office buildings in the Latvian climate conditions. The theoretical part of the thesis deals with methods of office building ventilation, supply air preheating and heat recovery as well as particularities of using ground-coupled air heat exchangers, their design parameters and their joint impact on the thermal performance. The engineering project part includes a ventilation system for an office building with an integrated ground-coupled air heat exchanger. By simulating energy consumption of the ventilation system for a duration of one year, the thesis analyzes the contribution of the heat exchanger to the overall energy consumption, which totals 9.53 MWh and 4.02 MWh a year, according to the desired parameters of the indoor climate. The possible alternative heat recovery solutions are investigated to reach by European Regional Development Fund project Nr.1.1.1.1/16/A/048 “NEARLY ZERO ENERGY SOLUTIONS FOR UNCLASSIFIED BUILDINGS”.

  16. Feasibility Assessment of Using Power Plant Waste Heat in Large Scale Horticulture Facility Energy Supply Systems

    Directory of Open Access Journals (Sweden)

    Min Gyung Yu

    2016-02-01

    Full Text Available Recently, the Korean government has been carrying out projects to construct several large scale horticulture facilities. However, it is difficult for an energy supply to operate stably and economically with only a conventional fossil fuel boiler system. For this reason, several unused energy sources have become attractive and it was found that power plant waste heat has the greatest potential for application in this scenario. In this study, we performed a feasibility assessment of power plant waste heat as an energy source for horticulture facilities. As a result, it was confirmed that there was a sufficient amount of energy potential for the use of waste heat to supply energy to the assumed area. In Dangjin, an horticultural area of 500 ha could be constructed by utilizing 20% of the energy reserves. In Hadong, a horticulture facility can be set up to be 260 ha with 7.4% of the energy reserves. In Youngdong, an assumed area of 65 ha could be built utilizing about 19% of the energy reserves. Furthermore, the payback period was calculated in order to evaluate the economic feasibility compared with a conventional system. The initial investment costs can be recovered by the approximately 83% reduction in the annual operating costs.

  17. Study of waste-heat recovery and utilization at the Farmington Municipal Power Plant. Final report, December 1, 1980-June 30, 1981

    Energy Technology Data Exchange (ETDEWEB)

    Leigh, G.G.; Edgel, W.R.; Feldman, K.T. Jr.; Moss, E.J.

    1982-03-01

    An examination was made of the technical and economc feasibility of utilizing waste heat from the Farmington Municipal Power Plant. First, the production cycles of the natural-gas-fired plant were assessed to determine the quantity and quality of recoverable waste heat created by the plant during its operation. Possibilities for utilizing waste heat from the exhaust gases and the cooling water were then reviewed. Hot water systems that can be used to retrieve heat from hot flue gases were investigated; the heated water can then be used for space heating of nearby buildings. The potential use of waste heat to operate a refrigeration plant was also analyzed. The use of discharged cooling water for hydroelectric generation was studied, as well as its application for commercial agricultural and aquaculture enterprises.

  18. Feasibility of geothermal heat use in the San Bernardino Municipal Wastewater Treatment Plant. Final report, September 1980-June 1981

    Energy Technology Data Exchange (ETDEWEB)

    Racine, W.C.; Larson, T.C.; Stewart, C.A.; Wessel, H.B.

    1981-06-01

    A system was developed for utilizing nearby low temperature geothermal energy to heat two high-rate primary anaerobic digesters at the San Bernardino Wastewater Treatment Plant. The geothermal fluid would replace the methane currently burned to fuel the digesters. A summary of the work accomplished on the feasibility study is presented. The design and operation of the facility are examined and potentially viable applications selected for additional study. Results of these investigations and system descriptions and equipment specifications for utilizing geothermal energy in the selected processes are presented. The economic analyses conducted on the six engineering design cases are discussed. The environmental setting of the project and an analysis of the environmental impacts that will result from construction and operation of the geothermal heating system are discussed. A Resource Development Plan describes the steps that the San Bernardino Municipal Water Department could follow in order to utilize the resource. A preliminary well program and rough cost estimates for the production and injection wells also are included. The Water Department is provided with a program and schedule for implementing a geothermal system to serve the wastewater treatment plant. Regulatory, financial, and legal issues that will impact the project are presented in the Appendix. An outline of a Public Awareness Program is included.

  19. Absorption heat pump for a potable water supply in a solar house

    Energy Technology Data Exchange (ETDEWEB)

    Elshamarka, S [Military Technical Coll., Cairo (EG)

    1991-01-01

    Solar houses usually have good potential in arid areas. These areas often suffer from not only a shortage of conventional energy sources, but also of potable water supplies. In this study, a solar air-conditioning system including an absorption heat pump, already in production since the early 1980s, is described for potable water production while performing its air-conditioning duty in a solar house. Compiled weather-conditions of the Hurgada area, on the Red Sea coast of Egypt, were employed for the prediction of the system's productivity, if it were installed in such a locality. An evaluation of the system's feasibility has been conducted. (author).

  20. Heat supply planning for the ecological housing community Munksøgård

    DEFF Research Database (Denmark)

    Karlsson, Kenneth Bernard; Petrovic, Stefan; Næraa, Rikke

    2016-01-01

    paper compares results from techno-economic energy system analysis, simple private-economic analysis and assessment of externalities related to the heat supply and discusses the differences in conclusions - is the economic optimal solution different from a system or private-economic point of view......? The techno-economic energy system analysis is done using TIMES-DTU model, which optimizes over all sectors in Denmark and all periods until 2050. The result from this model gives the least expensive solution from the overall system point of view. A spreadsheet model has been developed to do the private-economic...

  1. Heat supply planning for the ecological housing community Munksøgård

    DEFF Research Database (Denmark)

    Karlsson, Kenneth Bernard; Petrovic, Stefan; Næraa, Rikke

    2015-01-01

    paper compares results from techno-economic energy system analysis, simple private-economic analysis and assessment of externalities related to the heat supply and discusses the differences in conclusions - is the economic optimal solution different from a system or private-economic point of view......? The techno-economic energy system analysis is done using TIMES-DTU model, which optimizes over all sectors in Denmark and all periods until 2050. The result from this model gives the least expensive solution from the overall system point of view. A spreadsheet model has been developed to do the private-economic...

  2. Experimental evaluation of a heat pump for the water-supply heating of a public swimming pool

    International Nuclear Information System (INIS)

    López, R; Vaca, M; Terres, H; Lizardi, A; Morales, J; Chávez, S

    2017-01-01

    In this work the analysis of the thermodynamic behavior of heat pumps (HP) which supply the energy needed in the public pool at the Aquatic Center of Azcapotzalco was performed. There are 18 installed HP’s but only those needed to provide the energy required are alternately activated. The evaluation was conducted during May and June of 2015. We selected one of the HP to implement temperature and pressure gauges at the inlet and outlet of the compressor. The measurements were made every day at three times, 6:30, 13:00 and 18:00 hours. In a period of 24 hours, 1 000 L evaporated, there was no variation registered overnight, since the pool was covered with plastic to avoid loss of the fluid. The heat pump provided 150 kW to maintain the water temperature at the right level of operation, namely 28 °C. The coefficients of performance (COP) of the HP were 6.39 at 6:30, 7.42 at 13:00 and 7:32 at 18:00 hrs., values which are very close to the one provided by the manufacturer. (paper)

  3. Experimental evaluation of a heat pump for the water-supply heating of a public swimming pool

    Science.gov (United States)

    López, R.; Vaca, M.; Terres, H.; Lizardi, A.; Morales, J.; Chávez, S.

    2017-01-01

    In this work the analysis of the thermodynamic behavior of heat pumps (HP) which supply the energy needed in the public pool at the Aquatic Center of Azcapotzalco was performed. There are 18 installed HP’s but only those needed to provide the energy required are alternately activated. The evaluation was conducted during May and June of 2015. We selected one of the HP to implement temperature and pressure gauges at the inlet and outlet of the compressor. The measurements were made every day at three times, 6:30, 13:00 and 18:00 hours. In a period of 24 hours, 1 000 L evaporated, there was no variation registered overnight, since the pool was covered with plastic to avoid loss of the fluid. The heat pump provided 150 kW to maintain the water temperature at the right level of operation, namely 28 °C. The coefficients of performance (COP) of the HP were 6.39 at 6:30, 7.42 at 13:00 and 7:32 at 18:00 hrs., values which are very close to the one provided by the manufacturer.

  4. Nuclear refinery - advanced energy complex for electricity generation, clean fuel production, and heat supply

    International Nuclear Information System (INIS)

    McDonald, C.F.

    1992-01-01

    In planning for increased U.S. energy users' demand after the year 2000 there are essentially four salient vectors: (1) reduced reliance on imported crude oil; (2) provide a secure supply with stable economics; (3) supply system must be in concert with improved environment goals; and (4) maximum use to be made of indigenous resources. For the last decade of this century the aforementioned will likely be met by increasing utilization of natural gas. Early in the next century, however, in the U.S. and the newly industrializing nations, the ever increasing energy demand will only be met by the combined use of uranium and coal. The proposed nuclear refinery concept is an advanced energy complex that has at its focal point an advanced modular helium reactor (MHR). This nuclear facility, together with a coal feedstock, could contribute towards meeting the needs of the four major energy sectors in the U.S., namely electricity, transportation, industrial heating and chemical feedstock, and space and water heating. Such a nuclear/coal synergistic system would be in concert with improved air quality goals. This paper discusses the major features and multifaceted operation of a nuclear refinery concept, and identifies the enabling technologies needed for such an energy complex to become a reality early in the 21st century. (Author)

  5. Ohmic heating coil power supply using thyristor circuit breaker in a thermonuclear fusion device

    International Nuclear Information System (INIS)

    Tani, Keiji; Shimada, Ryuichi; Tamura, Sanae; Yabuno, Kohei; Koseki, Shoichiro.

    1982-01-01

    In a large scale Tokamak thermonuclear fusion device such as the critical plasma testing facility (JT60) presently under construction, mechanical breakers such as vacuum and air breakers are mostly used for interrupting DC heavy current which is supplied to the ohmic heating coils of inductive energy accumulation method. The practical use of the DC breakers employing thyristors has just been started because the history of thyristor development is short and thristors are still expensive, in spite of the advantages. In this paper, the circuit is investigated in which the excellent high speed controllability of thyristors is fully utilized, while the economy is taken into accout, and the experiment carried out with a unit model is described. It was found that a thyristor switch, which was constructed by connecting the high speed thyristors of peak off-state voltage rating 2,000 V and mean current rating 500 A in direct parallel, was able to interrupt 12.7 kA current in the power supply circuit of ohmic heating coils developed this time. In addition, the switch configuration was able to be greatly simplified. When the multistage raising of plasma current is required, the raise can be performed with a single thyristor breaker because it can make high speed control. Therefore, the capacity of the breaker can be doubly and drastically reduced. Also, if current unbalance might occur between thyristor switch units, it gives no problem since the time of reverse voltage after current interruption dispersed smaller as current increased. (Wakatsuki, Y.)

  6. Simulation of gas supply and consumption during heating season; Simulacija opskrbe potrosaca plinom tijekom ogrjevne sezone

    Energy Technology Data Exchange (ETDEWEB)

    Oklopcic, Z [INA-Naftaplin, Zagreb (Croatia)

    1997-12-31

    In this paper stochastic simulation model of gas supply and consumption during heating season is described. The simulation of gas supply is based on constant import and domestic production and varying production of underground storage which depends on current needs and quantity of gas in the storage. The basis for consumption simulation is the stochastic relationship between gas consumption and mean daily air temperature and type of the day, expressed in the form of linear regression model. Mean daily air temperatures, as one of basic causes of daily gas consumption variations, are simulated, on the basis of statistical characteristics and own air temperature measurements, as a first order autoregression model. By using the developed simulation model the statistical characteristics (expectation, standard deviation) of daily gas consumption and the difference between maximum possible daily supply and consumption (delivery safety margin) are derived for all days in the season. The definition of gas delivery safety is given and critical delivery probabilities for all days in the season and different safety margins are determined. Also, statistical characteristics of critical delivery duration depending on gas reserves status for underground storage is predicted. Predicted gas storage delivery rate is compared against predicted requirements, and on the basis of this comparison possible bottlenecks in gas delivery to consumers and course of future actions are indicated. (author). 3 tabs., 10 figs., 6 refs.

  7. Cob biomass supply for combined heat and power and biofuel in the north central USA

    International Nuclear Information System (INIS)

    Schmer, Marty R.; Dose, Heather L.

    2014-01-01

    Corn (Zea mays L.) cobs are being evaluated as a potential bioenergy feedstock for combined heat and power generation (CHP) and conversion into a biofuel. The objective of this study was to determine corn cob availability in north central United States (Minnesota, North Dakota, and South Dakota) using existing corn grain ethanol plants as a proxy for possible future co-located cellulosic ethanol plants. Cob production estimates averaged 6.04 Tg and 8.87 Tg using a 40 km radius area and 80 km radius area, respectively, from existing corn grain ethanol plants. The use of CHP from cobs reduces overall GHG emissions by 60%–65% from existing dry mill ethanol plants. An integrated biorefinery further reduces corn grain ethanol GHG emissions with estimated ranges from 13.9 g CO 2  equiv MJ −1 to 17.4 g CO 2  equiv MJ −1 . Significant radius area overlap (53% overlap for 40 km radius and 86% overlap for 80 km radius) exists for cob availability between current corn grain ethanol plants in this region suggesting possible cob supply constraints for a mature biofuel industry. A multi-feedstock approach will likely be required to meet multiple end user renewable energy requirements for the north central United States. Economic and feedstock logistics models need to account for possible supply constraints under a mature biofuel industry. - Highlights: • Corn cob biomass was estimated for the north central United States region. • Cobs were evaluated for combined heat and power generation and bioethanol. • Co-located ethanol plants showed a reduction in greenhouse gas emissions. • Biomass supply constraints may occur under a mature cellulosic ethanol scenario

  8. Comparison of ANN (MLP), ANFIS, SVM, and RF models for the online classification of heating value of burning municipal solid waste in circulating fluidized bed incinerators.

    Science.gov (United States)

    You, Haihui; Ma, Zengyi; Tang, Yijun; Wang, Yuelan; Yan, Jianhua; Ni, Mingjiang; Cen, Kefa; Huang, Qunxing

    2017-10-01

    The heating values, particularly lower heating values of burning municipal solid waste are critically important parameters in operating circulating fluidized bed incineration systems. However, the heating values change widely and frequently, while there is no reliable real-time instrument to measure heating values in the process of incinerating municipal solid waste. A rapid, cost-effective, and comparative methodology was proposed to evaluate the heating values of burning MSW online based on prior knowledge, expert experience, and data-mining techniques. First, selecting the input variables of the model by analyzing the operational mechanism of circulating fluidized bed incinerators, and the corresponding heating value was classified into one of nine fuzzy expressions according to expert advice. Development of prediction models by employing four different nonlinear models was undertaken, including a multilayer perceptron neural network, a support vector machine, an adaptive neuro-fuzzy inference system, and a random forest; a series of optimization schemes were implemented simultaneously in order to improve the performance of each model. Finally, a comprehensive comparison study was carried out to evaluate the performance of the models. Results indicate that the adaptive neuro-fuzzy inference system model outperforms the other three models, with the random forest model performing second-best, and the multilayer perceptron model performing at the worst level. A model with sufficient accuracy would contribute adequately to the control of circulating fluidized bed incinerator operation and provide reliable heating value signals for an automatic combustion control system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Supply of domestic hot Water at comfortable temperatures by low-temperature district heating without risk of Legionella

    DEFF Research Database (Denmark)

    Yang, Xiaochen

    disinfection efficacy for Legionella if supplied by LTDH, and inject no additives into the water. Thus, they can be considered as feasible sterilization solutions. In terms of the DHW system design methods, in addition to ensure the safe and hygiene DHW supply, the potential DHW systems should also...... temperature for space heating but lower than LTDH. Therefore, to meet the comfort and hygiene requirements for DHW supply, supplementary heating methods should be combined. However, one obstacle to realize the LTDH/ULTDH is the concern of the violation of the comfort and hygiene requirements of DHW supply....... According to the Danish standard, the supply for DHW should be able to reach 45 °C for the kitchen use and 40 °C for other uses for comfort. Regarding to the hygiene requirements, large DHW system with DHW storage tank and circulation has to use high temperature regime to get rid of Legionella. The storage...

  10. Radiation hygienic assessment of centralized heat and hot water supply of Bilibino village from Bilibin central nuclear heating- and power plant

    International Nuclear Information System (INIS)

    Eremin, V.A.; Marej, A.N.; Nechiporenko, N.I.; Rasskazov, A.P.; Sayapin, N.P.; Soldatov, G.E.; Shcherbinin, A.S.

    1983-01-01

    The experience in using an atomic power plant for heat and hot water supply of the village of Bilibino is outlined. Particular attention is given to the population radiation safety. It has been demonstrated that radiation safety of the system is ensured by maintaining fixed pressure levels in the heating media and by the hermetic state of heat exchanges. Water in the heat and hot water supply network meets the requirements for drinking water. Radioactive corrosion products were not detected in the test water. Gamma-radiation dose rate from the surface of heating devices and pipe-lines in the test premises did not exceed the natural background, that is, U.U1-0.025 mrad

  11. Comparative study for endenergy supply with nuclear district heating and with nuclear long distance energy

    International Nuclear Information System (INIS)

    Dietrich, G.

    1975-07-01

    The future energy supply of the Federal Republic of Germany will be orientated to secure energy carriers. Moreover economical energy consumption and environmental protection will be a force for an increased application of district heating and nuclear long distance energy. The technics of generation, transport and distribution of the two energy carriers will be discussed, besides a short review of application areas and potentials. The cost comparisons by models show that there are special advantages for both systems. Nevertheless the conclusions from the study can be to favour nuclear long distance energy because of its wide application range in the whole heat market. But there is also the competition with combined heat and power generation on fossil basis, as practised in many industrial companies. As a result of a regional analysis of the area Aachen-Moenchengladbach-Koeln, the cost advantages of the nuclear long distance energy as a parameter of current prices are confirmed. Nuclear long distance energy, in combination with the high temperature reactor and a developed technic of catalysts up to temperatures of 900 K, is an energy source which will be independant of regional necessities, secure, non pollutant and economic. (orig.) [de

  12. The electrohydraulic balance of the solar heat storage with autonomous power supply

    Directory of Open Access Journals (Sweden)

    M. K. Marahtanov

    2014-01-01

    Full Text Available The introduction of the paper emphasizes an increasingly important role of alternative power sources nowadays. At the same time, a solar collector (suntrap is one of the most frequent techniques to use the solar energy. It is an absorber that picks up solar radiation and heats a heat carrier circulating in the close loop. Then the heat is transferred to the heat accumulator that is integrated in the hot-tap water system (HWS.The paper presents a prospective circuit of the solar collector. It differs from the traditional one because, in addition to absorbing panel, it uses photoconverters to generate electric power for the circulating pump. The advantage of this system is that for operation such a solar energy converter has no need in external power sources, i.e. it is autonomous. The need to calculate the essential thermo-physical parameters that ensure no-break system operation was stated as a main objective of the work.The suggested circuit has a photocell panel to convert solar radiation into dc voltage of 12 V. In case of a lack of the solar energy an accumulator battery can be used for feeding. To ensure the no-break supply of power an adaptor is offered.To calculate a density distribution of solar radiation a sine law is offered depending on the time of day and geographical locality. This dependence was used to obtain the expressions for calculating the water temperature in boiler over daytime.Further, the calculations have been done for the operating conditions under which an efficient heat exchange will be provided with the minimum consumption of electric power for the heat carrier circulation in the first loop. For this purpose, a pump power was calculated depending on consumption and hydraulic losses of head in the pipeline. As a minimum required consumption the value has been chosen at which a laminar flow regime changes to the turbulent one because of the most efficient heat exchange being both in collector and in heat accumulator

  13. About opportunities of the sharing of city infrastructure centralized warmly - and water supply

    Science.gov (United States)

    Zamaleev, M. M.; Gubin, I. V.; Sharapov, V. I.

    2017-11-01

    It is shown that joint use of engineering infrastructure of centralized heat and water supply of consumers will be the cost-efficient decision for municipal services of the city. The new technology for regulated heating of drinking water in the condenser of steam turbines of combined heat and power plant is offered. Calculation of energy efficiency from application of new technology is executed.

  14. Feasibility and Supply Analysis of U.S. Geothermal District Heating and Cooling System

    Science.gov (United States)

    He, Xiaoning

    Geothermal energy is a globally distributed sustainable energy with the advantages of a stable base load energy production with a high capacity factor and zero SOx, CO, and particulates emissions. It can provide a potential solution to the depletion of fossil fuels and air pollution problems. The geothermal district heating and cooling system is one of the most common applications of geothermal energy, and consists of geothermal wells to provide hot water from a fractured geothermal reservoir, a surface energy distribution system for hot water transmission, and heating/cooling facilities to provide water and space heating as well as air conditioning for residential and commercial buildings. To gain wider recognition for the geothermal district heating and cooling (GDHC) system, the potential to develop such a system was evaluated in the western United States, and in the state of West Virginia. The geothermal resources were categorized into identified hydrothermal resources, undiscovered hydrothermal resources, near hydrothermal enhanced geothermal system (EGS), and deep EGS. Reservoir characteristics of the first three categories were estimated individually, and their thermal potential calculated. A cost model for such a system was developed for technical performance and economic analysis at each geothermally active location. A supply curve for the system was then developed, establishing the quantity and the cost of potential geothermal energy which can be used for the GDHC system. A West Virginia University (WVU) case study was performed to compare the competiveness of a geothermal energy system to the current steam based system. An Aspen Plus model was created to simulate the year-round campus heating and cooling scenario. Five cases of varying water flow rates and temperatures were simulated to find the lowest levelized cost of heat (LCOH) for the WVU case study. The model was then used to derive a levelized cost of heat as a function of the population density

  15. The small-scale production of hydrogen, with the co-production of electricity and district heat, by means of the gasification of municipal solid waste

    International Nuclear Information System (INIS)

    Hognert, Johannes; Nilsson, Lars

    2016-01-01

    Highlights: • Outline of a process for handling municipal solid waste potentially leading to reduced use of fossil transportation fuels. • The integration of waste gasification into a district heat plant leads to excellent energy efficiency. • Analysis based on actual production data from a district heat plant over the period of one year. • Simulation of a plant with productions of heat, power and gaseous hydrogen. - Abstract: Reducing the use of fossil fuels and increasing the recycling of waste are two important challenges for a sustainable society. Fossil fuels contribute to global warming whilst waste causes the pollution of land, water and air. Alternative fuels and innovative waste management systems are needed to address these issues. In this study a gasification process, fuelled with municipal solid waste, was assumed to be integrated into a heat plant to produce hydrogen, electricity and district heat. A whole system, which includes a gasification reactor, heat plant, steam cycle, pressure swing adsorption, gas turbine and compressors was modelled in Microsoft Excel and an energy balance of the system was solved. Data from the scientific literature were used when setting up the heat and mass balances of the gasification process as well as for assessment of the composition of the syngas. The allocation of energy of the products obtained in the process is 29% hydrogen, 26% electricity and 45% district heat. A significant result of the study is the high energy efficiency (88%) during the cold period of the year when the produced heat in the system is utilized for district heat. The system also shows a competitive energy efficiency (56.5%) all year round.

  16. Municipal opportunities

    International Nuclear Information System (INIS)

    Cousens, D.; Chuddy, B.; Gleeson, A.; Leckie, D.; Wahl, K.; McGarry, D.

    1997-01-01

    The panel discussing market opportunities for municipal electric companies was moderated by Markham Mayor Don Cousens. He expressed himself in favour of deregulation and was optimistic about the benefits it will bring to municipal electric utilities and their customers. Barry Chuddy, General Manager of Business Development for TransAlta Energy discussed the advantages of recent cogeneration and district energy for municipal utilities in Ontario and Quebec, and expressed his support for incentive-based regulation based on a level playing field, competitive generation, and a reasonable charge for stranded assets. Toronto City Councillor Dan Leckie described cogeneration and district energy as a tremendous opportunity to reduce the cost of doing business in the city core through local job creation and by keeping money in the local economy. Karl Wahl, General Manager of Hydro Mississauga expressed optimism that the government will move expeditiously toward competition, choice and lower-cost supply. David McGarry, President of Elecsar Engineering of Sarnia spoke about the significant job creating potential that deregulation will bring to the electrical industry. He cited several examples from Ontario and British Columbia

  17. High voltage power supplies for ITER RF heating and current drive systems

    International Nuclear Information System (INIS)

    Gassmann, T.; Arambhadiya, B.; Beaumont, B.; Baruah, U.K.; Bonicelli, T.; Darbos, C.; Purohit, D.; Decamps, H.; Albajar, F.; Gandini, F.; Henderson, M.; Kazarian, F.; Lamalle, P.U.; Omori, T.; Parmar, D.; Patel, A.; Rathi, D.; Singh, N.P.

    2011-01-01

    The RF heating and current drive (H and CD) systems to be installed for the ITER fusion machine are the electron cyclotron (EC), ion cyclotron (IC) and, although not in the first phase of the project, lower hybrid (LH). These systems require high voltage, high current power supplies (HVPS) in CW operation. These HVPS should deliver around 50 MW electrical power to each of the RF H and CD systems with stringent requirements in terms of accuracy, voltage ripple, response time, turn off time and fault energy. The PSM (Pulse Step Modulation) technology has demonstrated over the past 20 years its ability to fulfill these requirements in many industrial facilities and other fusion reactors and has therefore been chosen as reference design for the IC and EC HVPS systems. This paper describes the technical specifications, including interfaces, the resulting constraints on the design, the conceptual design proposed for ITER EC and IC HVPS systems and the current status.

  18. Variations of electric power and district heat supply in a city with 300,000 inhabitants; Varianten zur Strom- und Fernwaermeversorgung einer 300 000-Einwohner Stadt

    Energy Technology Data Exchange (ETDEWEB)

    Huevel, B.

    1997-12-31

    After the end of the regulation in 1997 which demanded the use of German coal, the municipal public utility will have several possibilities to substitute its own energy generation. Several variations are compared with each other taking into account technical and economic aspects. The variations are the continued operation of coal fuelled cogeneration power plant, the installation of a gas turbine with waste heat boiler to achieve a combined cycle power generation or the contribution to a large combined cycle power plant of the regional public utility. The comparison ends with the decision for one variation. The electric power and heat supply of the city of Karlsruhe is used as an example for the comparison. (orig./AKF) [Deutsch] Nach dem Auslaufen der Einsatzverpflichtung von deutscher Steinkohle 1997 eroeffnen sich dem kommunalen Versorgungsunternehmen verschiedene Moeglichkeiten, die Eigenerzeugung zu substituieren. Unter technischen und wirtschaftlichen Aspekten werden dazu Varianten gegenuebergestellt, wie Weiterbetrieb eines kohlebefeuerten Heizkraftwerkes mit Importkohle, Installation einer Gasturbine mit Abhitzekessel zur Realisierung eines GuD-Prozesses oder Beteiligung an einer grossen GuD des Regionalversorgers. Die Gegenueberstellung endet mit der Entscheidung fuer eine Variante. Die Strom- und Waermeversorgung der Stadt Karlsruhe wird als Beispiel fuer die Betrachtung verwendet. (orig./AKF)

  19. Change in heat load profile for typical Danish multi-storey buildings when energy-renovated and supplied with low-temperature district heating

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, Svend

    2013-01-01

    ) supply. When end-use-savings are implemented in buildings concurrent with the application of low-temperature district heating (DH) (supply=55°C, return=25°C) the heat demand profiles for the individual buildings will change. The reduction in peak load is important since it is the dimensioning foundation...... for the future DH-systems and in order to avoid oversized RE-based capacity, a long-term perspective needs to be taken. The results show that it is possible to design the DH-plants based on an average value of the 5 days with highest daily average loads without compromising with indoor thermal comfort. Applying...

  20. An autonomous nuclear power plant with integrated nuclear steam supply system designed for electric power and heat supply in remote areas with difficult access

    International Nuclear Information System (INIS)

    Adamovich, L.A.; Grechko, G.I.; Lapin, B.D.; Ulasevich, V.K.; Shishkin, V.A.

    1997-01-01

    The paper contains basic conceptual principles used to develop the technical assignment for an autonomous nuclear power plant with integrated nuclear steam supply system (NSSS) designed to provide heat and electricity for areas which are remote with difficult access. The paper also describes technical procedures and equipment, NPP thermal hydraulic flow chart, steam generator design, safety aspects as well as operational and maintenance procedures. (author)

  1. Ringkøbing-Skjern Energy Atlas for municipal energy planning

    DEFF Research Database (Denmark)

    Petrovic, Stefan; Karlsson, Kenneth Bernard

    2015-01-01

    Ringkøbing-Skjern is Denmark's largest municipality, located in the west part of Central Denmark Region. Its medium-term goal is to achieve 100 % self-sufficiency in renewable energy supply by 2020. To achieve this ambitious goal, future courses of action have been outlined in the municipality......'s energy strategy "Energy2020" and divided into five groups: increasing production from wind, bioenergy and other renewable energy sources, reducing heat demand in buildings and converting transportation sector to renewable energy. The analysis of technical, economic and environmental impacts...... of such a variety of technologies on the municipality's energy system requires highly detailed decision support system. For that purpose, GIS-based energy atlas has been developed for Ringkøbing-Skjern municipality. The data about energy supply and demand, transmission and distribution infrastructure, energy...

  2. Development of 8 MW Power Supply Based on Pulse Step Modulation Technique for Auxiliary Heating System on HL-2A

    International Nuclear Information System (INIS)

    Xu Weidong; Xuan Weimin; Yao Lieying; Wang Yingqiao

    2012-01-01

    The high voltage power supply (HVPS) based on pulse step modulation (PSM) has already been developed for the auxiliary heating system on HL-2A. This power supply consists of many switch power supplies, and its output voltage can be obtained by modulating their delay time and pulse widths. The PSM topology and control principle are presented in this paper. The simple algorithms for the control system are explained clearly. The switch power supply (SPS) module has been built and the test results show it can meet the requirements of the auxiliary heating system. Now, 112 SPS modules and the whole system have already been developed. Its maximum output is about 72 kV/93 A. The protection time is less than 5 μs. The different outputs of this power supply are used for the electron cyclotron resonant heating (ECRH) system with different duty ratios. The experimental results of the entire system are presented. The results indicate that the whole system can meet the requirements of the auxiliary heating system on HL-2A.

  3. A thermoelectric-conversion power supply system using a strontium heat source of high-level radioactive nuclear waste

    International Nuclear Information System (INIS)

    Chikazawa, Yoshitaka

    2011-01-01

    A thermoelectric-conversion power supply system with radioactive strontium in high-level radioactive waste has been proposed. A combination of Alkali Metal Thermo-Electric Conversion (AMTEC) and a strontium fluoride heat source can provide a compact and long-lived power supply system. A heat source design with strontium fluoride pin bundles with Hastelloy cladding and intermediate copper has been proposed. This design has taken heat transportation into consideration, and, in this regard, the feasibility has been confirmed by a three-dimensional thermal analysis using Star-CD code. This power supply system with an electric output of 1 MW can be arranged in a space of 50 m 2 and approximately 1.1 m height and can be operated for 15 years without refueling. This compact and long-lived power supply is suitable for powering sources for remote places and middle-sized ships. From the viewpoint of geological disposal of high-level waste, the proposed power supply system provides a financial base for strontium-cesium partitioning. That is, a combination of minor-actinide recycling and strontium-cesium partitioning can eliminate a large part of decay heat in high-level waste and thus can save much space for geological disposal. (author)

  4. Evaluation of a novel automated water analyzer for continuous monitoring of toxicity and chemical parameters in municipal water supply.

    Science.gov (United States)

    Bodini, Sergio F; Malizia, Marzio; Tortelli, Annalisa; Sanfilippo, Luca; Zhou, Xingpeng; Arosio, Roberta; Bernasconi, Marzia; Di Lucia, Stefano; Manenti, Angela; Moscetta, Pompeo

    2018-08-15

    A novel tool, the DAMTA analyzer (Device for Analytical Monitoring and Toxicity Assessment), designed for fully automated toxicity measurements based on luminescent bacteria as well as for concomitant determination of chemical parameters, was developed and field-tested. The instrument is a robotic water analyzer equipped with a luminometer and a spectrophotometer, integrated on a thermostated reaction plate which contains a movable carousel with 80 cuvettes. Acute toxicity is measured on-line using a wild type Photobacterium phosphoreum strain with measurable bioluminescence and unaltered sensitivity to toxicants lasting up to ten days. The EC50 values of reference compounds tested were consistent with A. fischeri and P. phosphoreum international standards and comparable to previously published data. Concurrently, a laboratory trial demonstrated the feasibility of use of the analyzer for the determination of nutrients and metals in parallel to the toxicity measurements. In a prolonged test, the system was installed only in toxicity mode at the premises of the World Fair "Expo Milano-2015″, a high security site to ensure the quality of the supplied drinking water. The monitoring program lasted for six months during which ca. 2400 toxicity tests were carried out; the results indicated a mean non-toxic outcome of -5.5 ± 6.2%. In order to warrant the system's robustness in detecting toxic substances, Zn was measured daily with highly reproducible inhibition results, 70.8 ± 13.6%. These results assure that this novel toxicity monitor can be used as an early warning system for protection of drinking water sources from emergencies involving low probability/high impact contamination events in source water or treated water. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Mobile central heating plant ensures the supply during the power-plant modernization. Planning-safe reconstruction; Mobile Heizzentrale sichert Versorgung waehrend Kraftwerksmodernisierung. Planungssicherer Umbau

    Energy Technology Data Exchange (ETDEWEB)

    Bernhard, Petra [Mobiheat GmbH, Friedberg (Germany). Presse- und Oeffentlichkeitsarbeit

    2012-09-15

    During the comprehensive energetic retrofitting of district heating plants in the spa resort of Badenweiler (Federal Republic of Germany) a mobile 2-MW heating plant from Mobilheat (Ebersberg, Federal Republic of Germany) was used for the heat supply. Thus, the installation of environmental friendly energy supply based on cogeneration plants could be implemented with planning security. This particularly was important because, among other things, the traditional spa resort, the Kurhaus as well as hotels and private customers depend on the heat supply system. These buildings have be supplied with thermal water also in the summer.

  6. Study on the Development of an Optimal Heat Supply Control Algorithm for Group Energy Apartment Buildings According to the Variation of Outdoor Air Temperature

    Directory of Open Access Journals (Sweden)

    Dong-Kurl Kwak

    2012-05-01

    Full Text Available In the present study, we have developed an optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in a group energy apartment. Heating load variation of a group energy apartment building according to the outdoor air temperature was predicted by a correlation obtained from calorimetry measurements of all households in the apartment building. Supply water temperature and mass flow rate were simultaneously controlled to minimize the heat loss rate through the distribution pipe line. A group heating apartment building located in Hwaseong city, Korea, which has 1473 households, was selected as the object building to test the present heat supply algorithm. Compared to the original heat supply system, the present system adopting the proposed control algorithm reduced the heat loss rate by 10.4%.

  7. What is the future potential for imports of combustible municipal waste to countries with extensive district heating hetworks? - A case study of Denmark

    DEFF Research Database (Denmark)

    Pizarro, Amalia Rosa; Münster, Marie; Salvucci, Raffaele

    2015-01-01

    In Europe landfilling is the most widely used method for managing municipal solid waste. By constrart, the northern European waste market is characterized by high capacities from energy recovery plants, mostly incineration in cogeneration facilities. In Denmark, there is an overcapacity of incine...... are described through linking of mathematical models, taking a holistic approach. In the short-term it pays off to import waste, avoiding landfilling; however, in the longer-term, benefits from waste trading will depend on the price of heat markets.......In Europe landfilling is the most widely used method for managing municipal solid waste. By constrart, the northern European waste market is characterized by high capacities from energy recovery plants, mostly incineration in cogeneration facilities. In Denmark, there is an overcapacity...

  8. Influencing the central heating technologies installed in homes: The role of social capital in supply chain networks

    International Nuclear Information System (INIS)

    Wade, Faye; Shipworth, Michelle; Hitchings, Russell

    2016-01-01

    The likely installation of, and potential energy savings from, low carbon technologies in domestic buildings is not only dependent on those who fit them, but also the broader supply chains of which they are part. Despite this, the role of supply chain actors has been largely overlooked in strategies seeking to encourage the installation of more sustainable domestic heating technologies. With reference to central heating, this paper responds through an ethnographic analysis of how plumbers' merchants and sales representatives can influence the work of heating installers in the United Kingdom. It applies two dimensions of the concept of ‘social capital’: relational and structural. Relational social capital focuses on the trust, loyalty and reciprocity at play in relations, whilst structural social capital considers how the strength of tie can influence those to whom people turn for advice and support. Together, these ideas demonstrate how relationships amongst these groups can serve to influence product choice and facilitate information exchange. The paper concludes by discussing how these supply chains might be engaged with as a means of encouraging the installation of low carbon domestic technologies. - Highlights: •Ethnography is used to investigate the relationships in heating supply chains. •Social capital is seen to be an important part of these relationships. •These relationships could help in the promotion of low carbon technologies.

  9. Exergoeconomic optimization of an ammonia–water hybrid absorption–compression heat pump for heat supply in a spraydrying facility

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars

    2015-01-01

    Spray-drying facilities are among the most energy intensive industrial processes. Using a heat pump to recover waste heat and replace gas combustion has the potential to attain both economic and emissions savings. In the case examined a drying gas of ambient air is heated to 200 C yielding a heat...... load of 6.1 MW. The exhaust air from the drying process is 80 C. The implementation of anammonia–water hybrid absorption–compression heat pump to partly cover the heat load is investigated. A thermodynamic analysis is applied to determine optimal circulation ratios for a number of ammonia mass...... fractions and heat pump loads. An exergo economic optimization is applied to minimize the lifetime cost of the system. Technological limitations are imposed to constrain the solution to commercial components. The best possible implementation is identified in terms of heat load, ammonia mass fraction...

  10. Sources of Water Supply and Water Quality for Local Consumption: The Case Study of Eco-Tourism Village, Suan Luang Sub- District Municipality, Ampawa District, Samut Songkram Province, Thailand

    OpenAIRE

    Paiboon Jeamponk; Tasanee Ponglaa; Patchapon Srisanguan

    2014-01-01

    The aim of this research paper was based on an examination of sources of water supply and water quality for local consumption, conducted at eco- tourism villages of Suan Luang Sub- District Municipality of Amphawa District, Samut Songkram Province. The study incorporated both questionnaire and field work of water testing as the research tool and method. The sample size of 288 households was based on the population of the district, whereas the selected sample water sources were from 60 househo...

  11. Integration of Building energy and energy supply simulations for low-energy district heating supply to energy-efficient buildings

    DEFF Research Database (Denmark)

    Dalla Rosa, Alessandro

    2012-01-01

    The future will demand implementation of C02 neutral communities, the consequences being a far more complex design of the whole energy system, since the future energy infrastructures will be dynamic and climate responsive systems. Software able to work with such level of complexity is at present...... a missing link in the development. In this paper is demonstrated how a link between a dynamic Building Simulation Programme (BSP) and a simulation program for District Heating (DH) networks can give important information during the design phase. By using a BSP it is possible to analyze the influence...... of the human behaviour regarding the building and link the results to the simulation program for DH networks. The results show that human behaviour can lead to 50% higher heating demand and 60% higher peak loads than expected according to reference values in standardized calculation of energy demand...

  12. Demand control on room level of the supply air temperature in an air heating and ventilation system

    DEFF Research Database (Denmark)

    Polak, Joanna; Afshari, Alireza; Bergsøe, Niels Christian

    2017-01-01

    air heating and ventilation system in a high performance single family house using BSim simulation software. The provision of the desired thermal conditions in different rooms was examined. Results show that the new control strategy can facilitate maintaining of desired temperatures in various rooms......The aim of this study was to investigate a new strategy for control of supply air temperature in an integrated air heating and ventilation system. The new strategy enables demand control of supply air temperature in individual rooms. The study is based on detailed dynamic simulations of a combined....... Moreover, this control strategy enables controlled temperature differentiation between rooms within the house and therefore provides flexibility and better balance in heat delivery. Consequently, the thermal conditions in the building can be improved....

  13. Realisation of a small hydro power plant in the water supply of the Gudo municipality; Realizzazione di una microcentrale idroelettrica sulla condotta di adduzione tra le sorgenti Valle del Cugnolo e il serbatoio Sasso Grande - Studio di fattibilita

    Energy Technology Data Exchange (ETDEWEB)

    Mutti, M.

    2008-12-15

    This report for the Swiss Federal Office of Energy (SFOE) presents the feasibility study for the renewal of the drinking-water supply of the Gudo Municipality, Switzerland, including a new micro-scale power plant at the entrance of the main water reservoir. The water quantities available are listed. The investment cost is evaluated. The major cost arises from the replacement of the main pipe connecting the remote spring to the water reservoir by a penstock following a new lie. The project is technically feasible, but economically not. However, considering the age and actual status of the water supply, the authorities will anyway soon have to take adequate measures.

  14. Exergoeconomic optimization of an ammonia-water hybrid heat pump for heat supply in a spray drying facility

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Markussen, Wiebke Brix; Reinholdt, Lars

    2014-01-01

    Spray drying facilities are among the most energy intensive industrial processes. Using a heat pump to recover waste heat and replace gas combustion has the potential to attain both economic and emissions savings. In the case examined a drying gas of ambient air is heated to 200 XC. The inlet flow...... rate is 100,000 m3/h which yields a heat load of 6.1 MW. The exhaust air from the drying process is 80 XC. The implementation of an ammonia-water hybrid absorption-compression heat pump to partly cover the heat load is investigated. A thermodynamic analysis is applied to determine optimal circulation...... ratios for a number of ammonia mass fractions and heat pump loads. An exergoeconomic optimization is applied to minimize the lifetime cost of the system. Technological limitations are applied to constrain the solution to commercial components. The best possible implementation is identified in terms...

  15. Sustainable energy supply for mushroom cultivation. Application of underground energy storage. Application of a heat pump for heat production. Feasibility study; Duurzame energievoorziening paddestoelen kwekerij. toepassing van energieopslag in de bodem. Toepassing van warmtepomp voor warmteopwekking. Een haalbaarheidsstudie

    Energy Technology Data Exchange (ETDEWEB)

    Koel, J.J. [EBS-Adviseurs, Veenendaal (Netherlands)

    2001-02-26

    The results of a feasibility study on the use of heat and cold storage and the use of an electric heat pump for the energy supply of a mushroom cultivation business (Verbruggen paddestoelen in Erp, Netherlands) are presented.

  16. Use of Nitrogen-15 Isotope Method in Soils and Ground Water to Determine Potential Nitrogen Sources Affecting a Municipal Water Supply in Kansas, USA

    Science.gov (United States)

    Townsend, M. A.; Macko, S. A.

    2004-12-01

    Nitrate-N concentrations have increased to greater than 10 mg/L in a municipal water supply in western Kansas from 1995 to 2002. A study was done by the Kansas Geological Survey using the nitrogen-15 natural abundance isotope method to determine potential sources for the increasing nitrate concentrations. Preliminary results of the isotope analyses on water samples suggest that animal waste and/or denitrification enrichment has affected the water supply. Soil samples from areas near the wells that were not treated with manure show a general increase of nitrogen-15 signature (+9 to +15 \\permil) to a depth of 5 m. Soils are silt loams with measurable carbonate (0.8 to 2 % by weight) in the profile, which may permit volatilization enrichment to occur in the soil profile. Wells in the area range from 11 to 20 m in alluvial deposits with depth to water at approximately 9 m). Nitrate-N values range from 8 to 26 mg/L. Nitrogen-15 values range from (+17 to +28 \\permil) with no obvious source of animal waste near the well sites. There are potential nearby long-term sources of animal waste - an abandoned sewage treatment plant and an agricultural testing farm. One well has a reducing chemistry with a nitrate value of 0.9 mg/L and a nitrogen-15 value of +17 \\permil suggesting that alluvial sediment variation also has an impact on the water quality in the study area. The other wells show values of nitrate and nitrogen-15 that are much greater than the associated soils. The use of nitrogen-15 alone permited limited evaluation of sources of nitrate to ground water particularly in areas with carbonate in the soils. Use of oxygen-18 on nitrate will permit the delineation of the processes affecting the nitrogen in the soil profile and determination of the probable sources and the processes that have affected the nitrogen in the ground water. Final results of the nitrogen-15 and oxygen-18 analyses will be presented.

  17. Intersex and alterations in reproductive development of a cichlid, Tilapia guineensis, from a municipal domestic water supply lake (Eleyele) in Southwestern Nigeria

    International Nuclear Information System (INIS)

    Adeogun, Aina O.; Ibor, Oju R.; Adeduntan, Sherifat D.; Arukwe, Augustine

    2016-01-01

    11-KT and GSI. These relationships suggest feminization and masculinization of male and female fish, respectively. - Highlights: • Occurrence and severity of intersex in Nigerian aquatic environment • Positive correlation between plasma hormone levels, Vtg and GSI. • Biomarker of endocrine disruption in tropical fish • PCBs burden in fish muscle and sediment from a municipal water supply lake • Possible health consequences of environmental contamination

  18. Intersex and alterations in reproductive development of a cichlid, Tilapia guineensis, from a municipal domestic water supply lake (Eleyele) in Southwestern Nigeria

    Energy Technology Data Exchange (ETDEWEB)

    Adeogun, Aina O.; Ibor, Oju R.; Adeduntan, Sherifat D. [Department of Zoology, University of Ibadan, Ibadan (Nigeria); Arukwe, Augustine, E-mail: arukwe@bio.ntnu.no [Department of Biology, Norwegian University of Science and Technology (NTNU), Høgskoleringen 5, N-7491 Trondheim (Norway)

    2016-01-15

    11-KT and GSI. These relationships suggest feminization and masculinization of male and female fish, respectively. - Highlights: • Occurrence and severity of intersex in Nigerian aquatic environment • Positive correlation between plasma hormone levels, Vtg and GSI. • Biomarker of endocrine disruption in tropical fish • PCBs burden in fish muscle and sediment from a municipal water supply lake • Possible health consequences of environmental contamination.

  19. Burnout in a high heat flux boiling system with forced supply of liquid through a plane jet

    International Nuclear Information System (INIS)

    Katto, Yoshiro; Ishii, Kazunori.

    1978-01-01

    As for pool boiling, the non-dimensional formula for the burnout heat flux of a simple, basic boiling system has been obtained. On the other hand, in forced convection boiling, the studies on the burnout in forced flow boiling in a channel have been continued, but the derivation of a non-dimensional formula applicable generally is far away from the realization because the phenomena are too complex. Accordingly, in this study, the result of the experiment on the burnout of a boiling system to which liquid is supplied by the plane jet flowing out of a thin rectangular nozzle installed near the front edge of a rectangular heating surface is reported. The experimental apparatus is described, and the experiment was carried out in the ranges of two jet thicknesses at the nozzle outlet, two incident angles of jet and from 1.5 to 15 m/s of jet velocity. Burnout occurs under the situation of sufficiently developed nuclear boiling. A part of the liquid supplied from a plane jet is blown apart by the vapor blowing out of the nuclear boiling liquid layer covering the heating surface in the nuclear boiling with sufficiently developed high heat flux. However, the nuclear boiling liquid layer itself continues to exist on the heating surface till burnout occurs. Only the entering velocity of the plane jet affects burnout heat flux. (Kako, I.)

  20. Heat supply systems using natural gas in the residential sector: The case of the agglomeration of Seoul

    International Nuclear Information System (INIS)

    Park, Hi-Chun; Kim, Hoseok

    2008-01-01

    Combined heat and power (CHP) and district heating (DH) promotion policies are based on the assumption of high energy efficiencies. In the last two decades, however, there has been a big increase in energy efficiencies of combined-cycle gas power plants (CCs) including CHPs and gas-condensing boilers. This study tries to verify the validity of the assumption of high energy efficiency of DH. The experience in the agglomeration of Seoul shows that DH in combination with large modern CHPs is not more energy efficient but substantially more expensive compared to individual gas heating by efficient condensing boilers in combination with CCs. We argue that the Korean government should review its CHP/DH support programs and abandon the so-called heat supply monopoly for DH operators in newly developed residential areas. Such a policy intervention only distorts the space heating market and wastes valuable financial resources. Furthermore, the public should be properly informed on energy efficiency as well as energy- and system-related costs of various heat supply systems. In the light of the present improvements in the performance of gas-condensing boilers and CCs, the validity of the assumption of high energy efficiency of CHP/DH in other countries has to be reviewed

  1. Study of an electrical heating system with ductless air supply and shape-stabilized PCM for thermal storage

    International Nuclear Information System (INIS)

    Lin, Kunping; Zhang, Yinping; Di, Hongfa; Yang, Rui

    2007-01-01

    A kind of electrical floor heating system with a shape-stabilized phase change material (PCM) which has been studied at Tsinghua University in our previous studies, can provide space heating during the whole day and can be controlled conventionally. However, this is not suitable for office buildings where no space heating is needed at night. The effective control is very important for the heating system in such buildings. In this paper, we studied a kind of new electrical floor heating system with ductless air supply and shape-stabilized PCM for thermal storage in order to overcome the shortcomings of the passive under-floor electric heating system with thermal storage. In this paper, we investigated its thermal performance by experiments and simulation, calculated the effects of various factors and discussed the application feasibility in different climate regions. The results show that the total electrical energy consumption was shifted from the peak period to the off-peak period, which would provide significant economic benefits because of the different day and night electricity tariffs. The system can be designed by choosing PCM with proper melting temperature and be controlled by varying velocity of air supply in different conditions

  2. The Polyvalent Heat Supply System for Experimental Building of the Passive Type (area of 300 m2 Based on Renewable and Alternative Energy Sources

    Directory of Open Access Journals (Sweden)

    Basok, B.I.

    2014-11-01

    Full Text Available Results of the development and implementation of heat supply system for experimental building of the passive type are presented, optimal operating conditions are investigated, guidelines for the creation of heat supply systems for passive type buildings are provided.

  3. Effectiveness of price adjustment clauses in district heat supply contracts. Consequences of the 2011 BGH rulings; Wirksamkeit von Preisanpassungsklauseln in Fernwaermelieferungsvertraegen. Konsequenzen der BGH-Urteile 2011

    Energy Technology Data Exchange (ETDEWEB)

    Buedenbender, Ulrich; Gromm, Marcel [TU Dresden (Germany). Lehrstuhl fuer Buergerliches Recht, Energiewirtschaftsrecht und Arbeitsrecht

    2011-07-01

    In 2011, the BGH had to decide for the first time on price adjustment clauses. There were four court rulings on price adjustment clauses in district heat supply contracts, and price adjustment clauses were considered to be ineffective in all cases. This is a trend similar to the rulings on gas supply contracts since 2005. This contribution discusses the consequences of the 2011 BGH rulings for future price adjustment clauses in district heat supply contracts. The contract partners, especially the customers of district heating utilities, must be sure whether a raised supply price will be based on an effective price adjustment clause, or whether it will enable the customer to refuse payment. (orig.)

  4. Vulnerability to Urban Heat Island in São Paulo Municipality: An Approach to Support the Mitigation Measures Implementation in Urban Planning

    Directory of Open Access Journals (Sweden)

    Juliana Siqueira-Gay

    2017-10-01

    Full Text Available In the practice of urban and environmental planning, especially in the context of adaptation to environmental changes, there is a demand for studies that integrate social, economic and environmental information of the population and related risk. Particularly in large urban centers, waterproofing and verticalization have the potential to increase local air temperature, triggering the phenomenon of heat islands. Therefore, this phenomenon has side effects such as public health problems, pollution and changes in the air circulation. In view of the risks and consequences of the urban heat islands, this paper aims to analyze the priority areas for implementing measures to mitigate the effects of the urban heat islands phenomenon in São Paulo City (Brazil. A vulnerability index was proposed considering the social and environmental dimensions, relating the capacity of adaptation, sensitivity and exposure to the occurrence of the phenomenon of urban heat islands. Besides that, measures to mitigate the effects associated with heat islands in urban planning were identified. The central regions are critical for exposure and the outskirts, for adaptive capacity and sensitivity, both considered priorities for the implementation of mitigation measures. In addition, strategies such as implementation and conservation of green spaces, preservation of water bodies, urban design change, as well as use of materials with high reflectance are also listed and partially foreseen in the Municipal Strategic Master Plan to mitigate the effects of urban heat island.

  5. From electricity to heat: A discourse-analytical policy study of the energy system conversion at national, municipal and household levels

    International Nuclear Information System (INIS)

    Perman, Karin

    2009-01-01

    The aim of this thesis is to analyse how space heating for single-family houses, and energy system conversion has been constructed and discussed at national, municipal and household levels. Political documents have been studied, and interviews have been carried out with politicians, civil servants and householders in the municipality of Falun. In order to study and analyse similarities and differences between these three political levels, the following main questions were asked: In which sense is the use of electrical heating formulated as problematic? How are the causes of these problems presented, and which solutions are suggested? What are the effects of how problems, causes and solutions are constructed? At the national level, the use of electricity produced by nuclear power was considered a problem. Initially the municipality's policy documents present the same problem, but there is a change of focus to the problem of imported electricity produced by fossil fuel, and the resulting emissions. At household level, the problem was often an old and badly functioning space-heating system. But some households did not formulate a problem before they converted. Instead they were influenced by their neighbours and thereby convinced. At all three political levels, there is consensus on the households' responsibility concerning energy transition. While industry tends to be considered incapable of cutting down its energy consumption, households are expected to take the responsibility seriously. Furthermore, within the household, the heating system tends to be constructed as a predominantly male concern. At all three levels, households are perceived as dependant on economical subsidies when taking the decision to convert from electrical heating. Although it is interesting that the interviewed householders only apply this view to others than themselves. They are convinced that other households need subsidies to act in an environmentally correct way. The discourse concerning

  6. ACCOUNTING FOR NONUNIFORMITY OF WATER CONSUMPTION IN THE EXHAUST AIR HEAT RECLAMATION SYSTEMS FOR HOT WATER SUPPLY

    Directory of Open Access Journals (Sweden)

    Samarin Oleg Dmitrievich

    2017-03-01

    Full Text Available This article is devoted to assessment of the influence of variation of daily hot water consumption on the predicted energy effect by using heat recovery of exhaust air in typical exhaust ventilation systems of the most commonly used flat buildings during their switch to the mechanical induction for the pre-heating of water for hot water supply. It outlines the general principle of the organization of this method of energy saving and presents the basic equations of heat transfer in the heat exchanger. The article proposes a simplified method of accounting for changes in the heat transfer coefficient of air-to-water heat exchanger with fluctuations of water demand using existing dependencies for this coefficient from the rate flow of heating and heated fluid through the device. It presents observations to identify the parameters of the real changes of water consumption during the day with the main quantitative characteristics of normally distributed random variables. Calculation of thermal efficiency of the heat exchange equipment using dimensionless parameters through the number of heat transfer under the optimal opposing scheme of fluid motion is completed under conditions of variable water flow rate for the type residential building of the П3-1/16 series using the Monte Carlo method for numerical modeling of stochastic processes. The estimation of the influence of fluctuation of the current water consumption on the instantaneous thermal efficiency factor of the heat exchanger and the total energy consumption of the building is given, and it is shown that the error of said calculation using average daily parameters is within the margin of usual engineering calculation.

  7. Investigation of ammonia/water hybrid absorption/compression heat pumps for heat supply temperatures above 100 °C

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Reinholdt, Lars; Markussen, Wiebke Brix

    2014-01-01

    The hybrid absorption/compression heat pump (HACHP) using ammonia-water as working fluid is a promising technology for development of a high temperature industrial heat pump. This is due to two properties inherent to the use of zeotropic mixtures: non-isothermal phase change and reduced vapour...... using these components. A technically and economically feasible solution is defined as one that satisfies constraints on the coefficient of performance (COP), low and high pressure, compressor discharge temperature and volumetric heat capacity. The ammonia mass fraction of the rich solution...

  8. ANÁLISIS DE LA CADENA DE VALOR HORTOFRUTÍCOLA DEL MUNICIPIO MARIANAO EN LA HABANA, CUBA / FRUITS AND VEGETABLES SUPPLY CHAIN ANALYSIS IN MARIANAO MUNICIPALITY AT HAVANA, CUBA

    Directory of Open Access Journals (Sweden)

    José Antonio Acevedo-Suárez

    2012-04-01

    Full Text Available En Cuba, el funcionamiento de las redes hortofrutícolas se rigen por la estructura del Ministerio de la Agricultura denominada Operación Producción-Acopio-Comercialización, que va desde un Puesto de Dirección Nacional hasta los municipales. De manera que, de la semilla al plato, las futas y vegetales fluyen por redes que reflejan su eficiencia en la disponibilidad en los mercados municipales. El objetivo general que plantea este estudio es analizar la estructura y funcionamiento de la cadena de valor hortofrutícola del municipio Marianao en La Habana, Cuba. La investigación abordará la identificación de eslabones y actores de esta cadena, la evaluación con los Modelos de Referencia de la Logística y Red de Valor y un análisis causa-efecto de los problemas de esta red. El resultado permite identificar la problemática municipal para proponer estrategias de mejoramiento en función de los elementos de las redes de valor.AbstractIn Cuba, the fruits and vegetables supply chain works with the structure established by the Ministry of Agriculture, named Production-Distribution-Sale Operation, which includes national directions to municipal management. So from the plant to the plate, fruits and vegetables flow through chains that reflect their efficiency on the availability in municipality markets. The general objective of this study is to analyze the structure and operation of the fruits and vegetables supply chain in Marianao municipality at Havana, Cuba. This investigation deals with the identification of the different links and members of this supply chain, its evaluation based on the Reference Models of Logistic and Value Chain and a cause-effect analysis about the problems in the above mentioned chain. The results permit to identify the problems of this municipality and to propose strategies in order to improve the situation, based on the elements of the supply chain.

  9. Design of helium-gas supplying facility of out-of-pile demonstration test for HTTR heat utilization system

    Energy Technology Data Exchange (ETDEWEB)

    Hino, Ryutaro; Fujisaki, Katsuo; Kobayashi, Toshiaki [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    1996-09-01

    One of the objectives of the High-Temperature Engineering Test Reactor (HTTR) is to demonstrate effectiveness of high-temperature heat utilization. Prior to connect a heat utilization system to the HTTR, a series of out-of-pile demonstration test is indispensable to improve components` performance, to demonstrate operation, control and safety technologies and to verify analysis codes for design and safety evaluation. After critical review and discussion on the out-of-pile demonstration test, a test facility have been designed. In this report, a helium-gas supplying facility simulated the HTTR system was described in detail, which supplies High-temperature helium-gas of 900degC to a steam reforming facility mocking-up the HTTR heat utilization system. Components of the Helium Engineering Demonstration Loop (HENDEL) were selected to reuse in the helium-gas supplying facility in order to decrease construction cost. Structures and specifications of new components such as a high-temperature heater and a preheater were decided after evaluation of thermal and hydraulic performance and strength. (author)

  10. The municipal platform for the generation of heat and power. Possibilities and limits; Die kommunale Erzeugungsplattform. Moeglichkeiten und Grenzen

    Energy Technology Data Exchange (ETDEWEB)

    Sigel, Ulrich [STEAG Energy Sevices GmbH, Essen (Germany)

    2013-04-01

    An important part of STEAG's corporate strategy under the new majority shareholder Stadtwerke-Konsortium Rhein-Ruhr is to establish STEAG as the leading municipal ''Generating, Trading and Service Platform'' in Germany. Based on the experience of cooperation with more than 100 municipal companies and a 75-year history of energy-solutions for industrial customers, a wide range of products and services for a close collaboration with the German ''Stadtwerke'' was developed. The framework of the ''energy turnaround'' in Germany influences these partnerships and provides momentum as well as limitations for the cooperation.

  11. ENERGY SUPPLY OF COMMERTIAL GREENHOUSE WITH THE GAS DRIVEN HEAT PUMP part II

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2013-12-01

    Full Text Available In this article a scheme of connection of heat exchanger for utilization of heat of flue gases to evaporator is proposed. In proposed scheme is ensured the minimum power of ventilator for air’s feeding to the evaporator of heat pump and compensation of pulsations of temperature of flue gases and pressure of ventilator. It is shown how to optimize parameters of heat exchanger in conditions of minimum of dissipation of energy with utilization of value of entransy. It is elaborated a scheme of coordinated control system of hydraulic transmissions, that transfers power on compressor of heat pump and electrical generator.

  12. Economic feasibility of heat supply from nuclear power plants in the United States

    International Nuclear Information System (INIS)

    Roe, K.K.; Oliker, I.

    1987-01-01

    Nuclear energy is regarded as competitive for urban district heating applications. Hot water heat transoport systems of up to 50 miles are feasible for heat loads over 1500 MWt, and heat load density of over 130 MWt/mi 2 is most suitable for nuclear applications. An incremental approach and a nuclear plant design provision for future heat extraction are recommended. Nuclear district heating technology status is discussed, particularly turbine design. Results of a study for retrofitting a major existing nuclear power plant to cogeneration operation are presented. The study indicates that for transmission distances up to 20 miles it is economical to generate and transport between 600 and 1200 MWt of district heat (author)

  13. Comparison of the Performance of Chilled Beam with Swirl Jet and Diffuse Ceiling Air Supply: Impact of Heat Load Distribution

    DEFF Research Database (Denmark)

    Bertheussen, Bård; Mustakallio, Panu; Kosonen, Risto

    2013-01-01

    The impact of heat load strength and positioning on the indoor environment generated by diffuse ceiling air supply and chilled beam with radial swirl jet was studied and compared. An office room with two persons and a meeting room with six persons were simulated in a test room (4.5 x 3.95 x 3.5 m3......) and Category B thermal environment in the meeting room at high heat load of 94 W∙m−2. The air distribution pattern was influenced by the convective flows from the heat sources. The maximum local velocity in the occupied zone was 0.23–0.26 m∙s−1. The diffuse ceiling supply did not ensure complete mixing...... temperature was controlled at 24 °C. The quality of the generated indoor environment as defined in ISO standard 7730 (2005) was assessed based on comprehensive physical measurements. The systems created Category A thermal environment in cooling situations at heat load of 50 W∙m−2 and 78 W∙m−2 (office room...

  14. A new tool of decentralized power supply. Micro-cogeneration unit for heat and power supply; Neuer Spielball der dezentralen Energieversorgung. Mikro-Waermekraftkopplung liefert Strom und Waerme

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-07-01

    Small fuel cell heating systems have renewed interest in decentralized power supply. The Dutch company EnAtEc recently announced their intention of presenting a micro-cogeneration unit ({mu}WK) at this year's ISH. The unit is a combination of a gas-fuelled high-efficiency boiler and a free-piston Stirling engine. With 1 kW{sub el} and 6 - 24 kW{sub th} it is suited for single-family dwellings. [German] Kleine Brennstoffzellenheizgeraete haben eine rege Diskussion um die dezentrale Energieversorgung entfacht. Juengst ueberraschte die niederlaendische Firma EnAtEc mit der Ankuendigung, zur ISH eine ''Mikro-Waermekraftkopplung'' ({mu}WK) vorzustellen. Das Geraet kombiniert einen Gas-Brennwertkessel mit einer Freikolben-Stirlingmaschine. Mit Leistungen von 1 kW{sub el} und 6 bis 24 kW{sub th} zielt die {mu}WK auf Einfamilienhaushalte. (orig.)

  15. The EDP data base as a marketing instrument in the supply industry. Methods and experiences in natural gas customer acquisition of the Munich municipal utilities

    International Nuclear Information System (INIS)

    Wind, F.; Disser, U.

    1994-01-01

    The natural gas marketing concept of the Munich municipal utilities describes the aims and objectives for the acquisition of new customers beyond the year 2000. One target is to extend the grids into new areas but also activate natural gas clients in densely populated areas. The marketing strategies concentrate on extensive advice and consulting co-ordinated by the customer service representatives with the support of electronic data processing. The following report shows how modern database systems were integrated into marketing activities by the Munich municipal utility company and describes the strategies selected in new areas and areas with a high customer population. (orig.) [de

  16. Below and above boiling point comparison of microwave irradiation and conductive heating for municipal sludge digestion under identical heating/cooling profiles.

    Science.gov (United States)

    Hosseini Koupaie, E; Eskicioglu, C

    2015-01-01

    This research provides a comprehensive comparison between microwave (MW) and conductive heating (CH) sludge pretreatments under identical heating/cooling profiles at below and above boiling point temperatures. Previous comparison studies were constrained to an uncontrolled or a single heating rate due to lack of a CH equipment simulating MW under identical thermal profiles. In this research, a novel custom-built pressure-sealed vessel which could simulate MW pretreatment under identical heating/cooling profiles was used for CH pretreatment. No statistically significant difference was proven between MW and CH pretreatments in terms of sludge solubilization, anaerobic biogas yield and organics biodegradation rate (p-value>0.05), while statistically significant effects of temperature and heating rate were observed (p-value<0.05). These results explain the contradictory results of previous studies in which only the final temperature (not heating/cooling rates) was controlled. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Municipal climate protection as a measure for sustainable energy supply under the conditions of globalization and liberalization? An empirical investigation considering the municipal actors and public utility companies; Kommunaler Klimaschutz als Instrument einer nachhaltigen Energieversorgung unter den Bedingungen von Globalisierung und Liberalisierung? Eine empirische Untersuchung unter besonderer Beruecksichtigung der Akteure Kommune und Stadtwerke

    Energy Technology Data Exchange (ETDEWEB)

    Bielitza-Mimjaehner, Ralf

    2007-03-01

    With the background of the threatening global warming that requires a reduction of greenhouse gas emission by 20 % until 2010 und by 80% until 2050 in Germany, t is reasonable to consider local or municipal climate protection activities. A climate protection politics ''from the bottom'' is not only contributing to a real greenhouse gas reduction, but also triggering the stagnant international climate politics and enhances the sustainable development on a local level. Due to this fact amongst others the Enquete commission of the German Bundestag ''sustainable energy supply under the conditions of globalization and liberalization'' identifies the municipal climate protection activities as important part within the mix of measures that will allow the initiation of an alteration of the actual energy system toward a sustainable energy supply in the long-run. The consequences of globalization and liberalization on the municipal level have not yet been discussed or considered by the Enquete commission. This thesis analyses the conditions induced by the globalization and liberalization on the municipal climate protection activities as constituent of a sustainable energy supply. The project is focusing on the municipal actors and the public utility companies as central point of the considerations. [German] Vor dem Hintergrund einer drohenden globalen Erwaermung, die eine Reduktion der klimawirksamen Treibhausgase bundesweit um 20 % bis 2010 und um 80 % bis 2050 noetig macht, sind Klimaschutzaktivitaeten auf einer lokalen oder kommunalen Ebene in mehreren Dimensionen sinnvoll. Den tatsaechlichen, bezifferbaren Reduktionen von CO2, die hier geleistet werden, gesellt sich ein ''vorbildhafter'' Druck auf eine stockende internationale Klimapolitik hinzu, ebenso leistet die ''Klimaschutzpolitik von unten'' einer nachhaltigen Entwicklung der lokalen Ebene durch Lerneffekte Vorschub. Unter anderem aus

  18. Utilisation of geothermal energy by the municipal works in Neubrandenburg

    International Nuclear Information System (INIS)

    Jahnke, H.

    1994-01-01

    A long distance energy supply plant has been operated on the basis of geothermal energy in Neubrandenburg since September 1988. At present it is still the largest heat generation plant for the utilisation of low thermal pore storage in Germany. The setup and the function of the plant are explained. After the municipal works of Neubrandenburg took over the plant, it was redesigned in order to give a better guarantee for the supply, to improve the economic efficiency and to minimise the environmental impact. At present long distance energy can be provided at a price of 99,00 DM/Mwh for 2000 utilisation hours per year. (BWI) [de

  19. Open loop control of filament heating power supply for large volume plasma device

    Energy Technology Data Exchange (ETDEWEB)

    Sugandhi, R., E-mail: ritesh@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat 382428 (India); Homi Bhabha National Institute, Mumbai 400094 (India); Srivastava, P.K.; Sanyasi, A.K. [Homi Bhabha National Institute, Mumbai 400094 (India); Srivastav, Prabhakar [Institute for Plasma Research, Gandhinagar, Gujarat 382428 (India); Homi Bhabha National Institute, Mumbai 400094 (India); Awasthi, L.M., E-mail: kushagra.lalit@gmail.com [Institute for Plasma Research, Gandhinagar, Gujarat 382428 (India); Homi Bhabha National Institute, Mumbai 400094 (India); Mattoo, S.K. [Homi Bhabha National Institute, Mumbai 400094 (India)

    2017-02-15

    A power supply (20 V, 10 kA) for powering the filamentary cathode has been procured, interfaced and integrated with the centralized control system of Large Volume Plasma Device (LVPD). Software interface has been developed on the standard Modbus RTU communication protocol. It facilitates the dashboard for configuration, on line status monitoring, alarm management, data acquisition, synchronization and controls. It has been tested for stable operation of the power supply for the operational capabilities. The paper highlights the motivation, interface description, implementation and results obtained.

  20. Open loop control of filament heating power supply for large volume plasma device

    International Nuclear Information System (INIS)

    Sugandhi, R.; Srivastava, P.K.; Sanyasi, A.K.; Srivastav, Prabhakar; Awasthi, L.M.; Mattoo, S.K.

    2017-01-01

    A power supply (20 V, 10 kA) for powering the filamentary cathode has been procured, interfaced and integrated with the centralized control system of Large Volume Plasma Device (LVPD). Software interface has been developed on the standard Modbus RTU communication protocol. It facilitates the dashboard for configuration, on line status monitoring, alarm management, data acquisition, synchronization and controls. It has been tested for stable operation of the power supply for the operational capabilities. The paper highlights the motivation, interface description, implementation and results obtained.

  1. Heating and dehydration of grain and cereals at a combined energy supply

    Directory of Open Access Journals (Sweden)

    Sergey Zverev

    2018-02-01

    Full Text Available The paper dwells on the development of experimental dependencies of heating and dehydration of grain and cereals when varying the irradiance, ambient temperature in the heat treatment zone and the initial moisture content of product, and the development of the mathematical models for heating and dehydration of some grains and cereals. The grain was heated on the laboratory equipment with quartz halogen linear infrared emitters. The irradiance on the working surface in the treatment zone was determined by calculation using a specially developed program. The ambient temperature was determined by a thermocouple thermometer placed in a ceramic tube. The grain temperature was estimated as average by weight by a thermocouple thermometer after its transfer into a thermally insulated container. The following dependencies have been obtained: 1 - Temperature dependence of the heating time for different heating modes and initial moisture content. 2 - Dependence of moisture content on the heating time under different conditions and initial moisture content. 3 - Dependence of moisture content on a temperature under different conditions and constant initial humidity. The models of the heat-moisture exchange and dehydration processes have been created, and the model parameters K0 and KT of the temperature dependence of some grains have been identified, as well as their dependence on moisture content and treatment modes has been evaluated. It has been established that this model describes adequately the process of dehydration to an extent limited by the upper temperature value of grain not much more than 100 ºС. Within not limited to the upper temperature value of grain not much more than 100 ºС. From the presented graphs and earlier obtained results for barley and millet, it can be assumed that the model describes adequately experimental data on the small-sized (3 - 5 mm objects.

  2. Planning of the district heating system in copenhagen from an economic perspective comparing energy-savings versus fossil-free supply

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, Svend

    geothermal heating plants, may lead to oversized heating plants that are too expensive to build compared to implementing energy savings. Therefore reducing heat demand of existing buildings before investing in supply capacity will save society half the investment, indicating the importance of carrying out......The Danish government has adopted a long-term energy policy of being independent of fossil fuels by 2050, and that the energy supply for buildings should be independent of fossil fuels by 2035. Therefore, urgent action is needed to meet the requirements for the future energy system. One way...... of becoming independent of fossil fuels is to energy upgrade the existing building stock and change the energy supply to renewable energy sources. A sustainable way of providing space heating (SH) and domestic hot water (DHW) to buildings in densely populated areas is through the use of district heating (DH...

  3. Industrial water supply for the Kursk TETs-1 heating and electric power plant with the ecological safety of the River Seim taken into account

    International Nuclear Information System (INIS)

    Kyakk, V. A.

    2009-01-01

    The Kursk TETs-1 heating and electric power plant is discussed as an illustration of preventing thermal contamination of its water supply (River Seim) by circulating water. An effective water supply system is taken to be one for which the overheating of the water at a monitoring site (near the outlet location) does not exceed an approved level for the water use conditions. The required cooling capacity of a spray pond for circulating and flow-through water supplies is determined.

  4. ON THE ISSUE OF RATIONAL ORGANIZATION OF THE TEXTILE AND KNITWEAR ENTERPRISES HEAT AND POWER SUPPLY SYSTEM

    Directory of Open Access Journals (Sweden)

    V. N. Romaniuk

    2016-01-01

    Full Text Available The paper considers organization of the industrial enterprise heat and power supply system (HPSS, to be rational from the structure and flow parameter standpoint. Developing HPSS is one of the main lines of implementing energy-saving potential in volumes complying with dictates of the time on reducing the production cost energy component, which is especially vital for the light industry enterprises of Belarus. To reduce the complexity of the task the authors employ the hierarchical structure of HPSS. With regard to textile and knitwear enterprises, they show the irregularity of energy supply on the one hand, and of energy use on the other. The finishing departments of the specified enterprises ensure their thermo-technological status. It is proverbial that accomplished in terms of energy thermo-technological enterprises should not consume the electric energy produced in condensation electric power plants. Instead, for their production needs, they should use thermal energy and electricity generated in the CHP. At the same time, steam turbine CHPs of low power, and consequently of low initial parameters, cannot provide the required electrical and heat energy flow generation balance. The indicated circumstance among others accounts for prevalence of condensation electric power plants in the scheme of electrogenerating capacities that provide work for the light industry enterprises. And this leads to irregularity of their energy supply. Transition to gas CHPs with required scheme of the energy flow generation is associated primarily with creation of inherent generating sources, which in its turn poses a number of challenges on modification of the thermal treatment schemes of technological flows. The problem is solved in package with developing energy consumption of the finishing department as well as the entire enterprise. The study shows the capability of utilizing low pressure hot water alongside with steam, which paves the way to the recuperative

  5. Solar thermal energy / exhaust air heat pump / wood pellet furnace for a sustainable heat supply of low energy buildings in older buildings; Solarthermie / Abluft-Waermepumpe / Pelletofen. Kombisysteme zur nachhaltigen Waermeversorgung von Niedrigenergiehaeusern im Gebaeudebestand

    Energy Technology Data Exchange (ETDEWEB)

    Diefenbach, Nikolaus; Born, Rolf [Institut Wohnen und Umwelt GmbH, Darmstadt (Germany); Staerz, Norbert [Ingenieurbuero inPlan, Pfungstadt (Germany)

    2009-11-13

    The research project under consideration reports on combination systems for a sustainable heat supply for low-energy buildings in older building. For this, a central and decentralized system configuration consisting of solar thermal energy, exhaust air heat pump and wood pellet furnace are presented. Solutions for an interaction of these three heat suppliers in one plant are designated regarding the control strategy. The fundamentals of the computerized simulations for the central and decentralized system are presented. A cost estimate with both variants of the combination system as well as a comparison with conventional energy-saving heat supply systems follow.

  6. A multipurpose pollution-free high temperature heat supply system for 21st century service

    International Nuclear Information System (INIS)

    McDonald, C.F.

    1996-01-01

    In the 21st century, increasing environmental concerns, together with decreasing fossil fuel resources, will result in a gradual transition in the power industry to the use of nuclear energy on a global scale. The demand for energy to meet growing populations and the needs of industry, transportation, and the heating market, will be based on the increasing use of electricity and hydrogen, these being produced, first by fission and later by fusion reactors. The realization of this scenario will be the deployment of a high temperature reactor (HTR), which together with a heat transport loop constitutes a nuclear heat source (NHS). The initial large-scale use of the NHS will likely be for nuclear process heat, namely the fossil-free production of hydrogen by thermochemical water splitting. The same NHS will also be used for the high efficiency generation of electricity using an indirect cycle helium gas turbine. An important stepping stone towards this goal will be the operation of a high temperature test reactor (HTTR) currently under construction in Japan. This will pave the way for introduction of the HTR for hydrogen production and electricity generation around the year 2020. This paper puts into perspective technological aspects of a futuristic, pollution free, high temperature nuclear heat source

  7. Hydrogen production by water-splitting using heat supplied by a high-temperature reactor

    International Nuclear Information System (INIS)

    Courvoisier, P.; Rastoin, J.; Titiliette, Z.

    1976-01-01

    Some aspects of the use of heat of nuclear origin for the production of hydrogen by water-splitting are considered. General notions pertaining to the yield of chemical cycles are discussed and the heat balance corresponding to two specific processes is evaluated. The possibilities of high temperature reactors, with respect to the coolant temperature levels, are examined from the standpoint of core design and technology of some components. Furthermore, subject to a judicious selection of their characteristics, these reactors can lead to excellent use of nuclear fuel. The coupling of the nuclear reactor with the chemical plant by means of a secondary helium circuit gives rise to the design of an intermediate heat exchanger, which is an important component of the overall installation. (orig.) [de

  8. Flexible, pre-insulated pipelines for heat and water supply. Systems with integrated quality and service; Flexible, vorgedaemmte Rohrsysteme fuer die Versorgungstechnik. Gesamtsysteme mit Qualitaet und Service

    Energy Technology Data Exchange (ETDEWEB)

    Hetzel, Michaela [Uponor Central Europe, Hassfurt (Germany). Unternehmenskommunikation

    2010-10-15

    Flexible pipes are suited for heat distribution, cooling water and freshwater transport. Uponor uses a modified, cross-linked polythene for insulation. The material is flexible, ageing-resistant, and will reduce the heat loss. Pipes are supplied to the construction site within two days, cut to measure and with all required parts. (orig.)

  9. Gaseous emissions during concurrent combustion of biomass and non-recyclable municipal solid waste

    Directory of Open Access Journals (Sweden)

    Oakey John

    2011-02-01

    Full Text Available Abstract Background Biomass and municipal solid waste offer sustainable sources of energy; for example to meet heat and electricity demand in the form of combined cooling, heat and power. Combustion of biomass has a lesser impact than solid fossil fuels (e.g. coal upon gas pollutant emissions, whilst energy recovery from municipal solid waste is a beneficial component of an integrated, sustainable waste management programme. Concurrent combustion of these fuels using a fluidised bed combustor may be a successful method of overcoming some of the disadvantages of biomass (high fuel supply and distribution costs, combustion characteristics and characteristics of municipal solid waste (heterogeneous content, conflict with materials recycling. It should be considered that combustion of municipal solid waste may be a financially attractive disposal route if a 'gate fee' value exists for accepting waste for combustion, which will reduce the net cost of utilising relatively more expensive biomass fuels. Results Emissions of nitrogen monoxide and sulphur dioxide for combustion of biomass are suppressed after substitution of biomass for municipal solid waste materials as the input fuel mixture. Interactions between these and other pollutants such as hydrogen chloride, nitrous oxide and carbon monoxide indicate complex, competing reactions occur between intermediates of these compounds to determine final resultant emissions. Conclusions Fluidised bed concurrent combustion is an appropriate technique to exploit biomass and municipal solid waste resources, without the use of fossil fuels. The addition of municipal solid waste to biomass combustion has the effect of reducing emissions of some gaseous pollutants.

  10. Gaseous emissions during concurrent combustion of biomass and non-recyclable municipal solid waste.

    Science.gov (United States)

    Laryea-Goldsmith, René; Oakey, John; Simms, Nigel J

    2011-02-01

    Biomass and municipal solid waste offer sustainable sources of energy; for example to meet heat and electricity demand in the form of combined cooling, heat and power. Combustion of biomass has a lesser impact than solid fossil fuels (e.g. coal) upon gas pollutant emissions, whilst energy recovery from municipal solid waste is a beneficial component of an integrated, sustainable waste management programme. Concurrent combustion of these fuels using a fluidised bed combustor may be a successful method of overcoming some of the disadvantages of biomass (high fuel supply and distribution costs, combustion characteristics) and characteristics of municipal solid waste (heterogeneous content, conflict with materials recycling). It should be considered that combustion of municipal solid waste may be a financially attractive disposal route if a 'gate fee' value exists for accepting waste for combustion, which will reduce the net cost of utilising relatively more expensive biomass fuels. Emissions of nitrogen monoxide and sulphur dioxide for combustion of biomass are suppressed after substitution of biomass for municipal solid waste materials as the input fuel mixture. Interactions between these and other pollutants such as hydrogen chloride, nitrous oxide and carbon monoxide indicate complex, competing reactions occur between intermediates of these compounds to determine final resultant emissions. Fluidised bed concurrent combustion is an appropriate technique to exploit biomass and municipal solid waste resources, without the use of fossil fuels. The addition of municipal solid waste to biomass combustion has the effect of reducing emissions of some gaseous pollutants.

  11. On the way towards smart energy supply in cities: The impact of interconnecting geographically distributed district heating grids on the energy system

    DEFF Research Database (Denmark)

    Dominkovic, D. F.; Bačeković, I.; Sveinbjörnsson, D.

    2017-01-01

    assessed. Moreover, the impact of industrial waste heat on the DH supply was also assessed. In the reference year (2013) two out of four interconnections proved to be economically viable. The results for the future energy system (2029) showed that interconnecting geographically distributed DH grids reduces...... of the future energy supply system with interconnected DH grids and installed industrial waste heat recuperation results in the lowest primary energy demand, emissions and costs. Finally, the benefits of the interconnected DH grid, in terms of system flexibility, CO2 emissions, total costs and energy efficiency...... primary energy supply by 9.5%, CO2 emissions by 11.1% and total system costs by 6.3%. Inclusion of industrial waste heat in the fully interconnected DH grid reduced primary energy supply for an additional 3%, CO2 emissions for an additional 2.2% and total system costs for an additional 1.3%. The case...

  12. Computer control of the high-voltage power supply for the DIII-D electron cyclotron heating system

    International Nuclear Information System (INIS)

    Clow, D.D.; Kellman, D.H.

    1992-01-01

    This paper reports on the DIII-D Electron Cyclotron Heating (ECH) high voltage power supply which is controlled by a computer. Operational control is input via keyboard and mouse, and computer/power supply interfact is accomplished with a Computer Assisted Monitoring and Control (CAMAC) system. User-friendly tools allow the design and layout of simulated control panels on the computer screen. Panel controls and indicators can be changed, added or deleted, and simple editing of user-specific processes can quickly modify control and fault logic. Databases can be defined, and control panel functions are easily referred to various data channels. User-specific processes are written and linked using Fortran, to manage control and data acquisition through CAMAC. The resulting control system has significant advantages over the hardware it emulates: changes in logic, layout, and function are quickly and easily incorporated; data storage, retrieval, and processing are flexible and simply accomplished; physical components subject to wear and degradation are minimized. In addition, the system can be expanded to multiplex control of several power supplies, each with its own database, through a single computer console

  13. Computer control of the high-voltage power supply for the DIII-D Electron Cyclotron Heating system

    International Nuclear Information System (INIS)

    Clow, D.D.; Kellman, D.H.

    1991-10-01

    The D3-D Electron Cyclotron Heating (ECH) high voltage power supply is controlled by a computer. Operational control is input via keyboard and mouse, and computer/power supply interface is accomplished with a Computer Assisted Monitoring and Control (CAMAC) system. User-friendly tools allow the design and layout of simulated control panels on the computer screen. Panel controls and indicators can be changed, added or deleted, and simple editing of user-specific processes can quickly modify control and fault logic. Databases can be defined, and control panel functions are easily referred to various data channels. User-specific processes are written and linked using Fortran, to manage control and data acquisition through CAMAC. The resulting control system has significant advantages over the hardware it emulates: changes in logic, layout, and function are quickly and easily incorporated; data storage, retrieval, and processing are flexible and simply accomplished, physical components subject to wear and degradation are minimized. In addition, the system can be expanded to multiplex control of several power supplied, each with its own database, through a single computer and console. 5 refs., 4 figs., 1 tab

  14. A portable backup power supply to assure extended decay heat removal during natural phenomena-induced station blackout

    International Nuclear Information System (INIS)

    Proctor, L.D.; Merryman, L.D.; Sallee, W.E.

    1989-01-01

    The High Flux Isotope Reactor (HFIR) is a light water cooled and moderated flux-trap type research reactor located at Oak Ridge National Laboratory (ORNL). Coolant circulation following reactor shutdown is provided by the primary coolant pumps. DC-powered pony motors drive these pumps at a reduced flow rate following shutdown of the normal ac-powered motors. Forced circulation decay heat removal is required for several hours to preclude core damage following shutdown. Recent analyses identified a potential vulnerability due to a natural phenomena-induced station blackout. Neither the offsire power supply nor the onsite emergency diesel generators are designed to withstand the effects of seismic events or tornadoes. It could not be assured that the capacity of the dedicated batteries provided as a backup power supply for the primary coolant pump pony motors is adequate to provide forced circulation cooling for the required time following such events. A portable backup power supply added to the plant to address this potential vulnerability is described

  15. Comparative ecobalancing accounting of semi-central house heat supply from wood residues; Vergleichende Oekobilanzierung der semi-zentralen Hauswaermebereitstellung aus Holzreststoffen

    Energy Technology Data Exchange (ETDEWEB)

    Biemann, Kirsten

    2015-07-01

    In 2008 almost 40 percent of the German final energy demand was used for room heating and hot water supply. To decrease environmental burdens and to save fossil resources a restructuring of the heating sector is needed. Therefore legislation enforces higher insulation standards of buildings and a more frequent use of renewable energies as well as heating networks. Wood as a renewable and storable energy source is an attractive fuel. However, it must be used as efficiently as possible because of limited wood supplies. Connecting buildings via a heating network is a good option since bigger heating plants can operate at higher efficiencies than small heaters. However, the higher insulation standards of the buildings often oppose the construction of a heating network, because heating networks work best with high energy demands and low network lengths. Therefore the environmental and economic feasibility of new heating networks needs to be checked beforehand. This thesis explores the environmental burdens of different semi- centralized heating networks using wood residues as fuel. A semi- centralized heating network is a network with no more than 500 customers and a heating plant with less than 5 MWth. While wood residues are used in the base load plant, peak load is covered by a gas heating plant. As a method to analyze the potential environmental burdens of the heat supply a life cycle assessment according to ISO 14040/44 is used. Opposed to former life cycle assessment studies, construction and operation of the network is included in the assessment. Even though the environmental impacts of the semi- centralized heating from wood residues are dominated by the heat supply, an observation of the impacts solely at the heating plant is not sufficient. By varying the boundary conditions of the heating network two main contributors to the environmental impacts are found. In addition to the heat production at the plant the type of the buildings in the settlement has a huge

  16. Feasibility of geothermal heat use in the San Bernardino Municipal Wastewater Treatment Plant. Final report, September 1980-June 1981

    Energy Technology Data Exchange (ETDEWEB)

    Racine, W.C.; Larson, T.C.; Stewart, C.A.; Wessel, H.B.

    1981-06-01

    The results of the feasibility study for utilizing low temperature geothermal heat in the City of San Bernardino Wastewater Treatment Plant are summarized. The study is presented in terms of preliminary engineering design, economic analysis, institutional issues, environmental impacts, resource development, and system implementation.

  17. Supply of wood fuel from small-scale woodlands for small-scale heating

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    This report summarises the findings of a study aimed at stimulating a market for wood fuels. A desk study of harvesting in existing small woodland was conducted, and thirteen case studies covering early broadleaved thinnings, mixed broadleaved coppice, and crownwood, scrub and residues were examined to obtain information on woodland types, wood fuel supply, and combustion equipment. Details are given of the measurement of moisture content of woodchips and stacked roundwood, wood volume and green density, harvesting options, crop and site variables, and production and costs of wood fuels. Usage of wood fuels, and the drying of small roundwood was considered. (UK)

  18. Renovation and rehabilitation of Didi Digomi District Heat Supply Plant (No.48) in Tbilisi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    An investigational study was conducted on the project for energy conservation and reduction in greenhouse effect gas emission at the existing district heating plant in Tbilisi City, Georgia. In the project, the following are conducted for the district heating plants in the Didi-Digomi section and Saburtalo section: renewal/higher efficiency of boiler equipment, adoption of cogeneration using gas turbine, improvement of hot water pipeline and improvement of equipment at heat users. As a result of the study, one plan for cogeneration of 2 units x 6MW class in each section was good in terms of economical efficiency and expenses vs. effects, and the other plan for cogeneration of 17 units (8 units and 9 units) x 6MW class was good in terms of the generated output and regional needs. The amount of energy conservation to be made by the former plan totaled 22,678 toe/y in both sections. The amount of greenhouse effect gas reduction is 70,170 t-CO2/y. The internal earning rate is 1.707% in the Didi-Digomi section and 2.249% in the Saburtalo section. The project profit is lower than the initial investment cost, and therefore, it is necessary to consider the profit from the CO2 emission right. (NEDO)

  19. Development of a direct expansion solar assisted heat pump for hot water supply

    International Nuclear Information System (INIS)

    Abdesselam Hamloui; Ong, K.S.; Than Cheok Fah; Masjuki Hassan

    2000-01-01

    Experimental investigations were conducted on the direct expansion solar assisted Heat Pump (DESAHP). Refrigerant R-22 was expanded in the solar collector which also acted as the evaporator in a conventional vapor compression refrigerating machine. The experiments were conducted under conditions of high and low solar radiation, with evaporator completely shaded from the sun, and at night. System thermal performance was determined by measuring refrigerant flow rate, temperature and pressure at numerous points in the system. The results showed that 227-l of water could be heated from 3O degree to 55 degree C in about 105 minutes. Higher water temperatures were obtained during hot sunny days. The coefficient of performance of heating, COP h , ranged from 11 to 4.7, depending upon operating conditions. The total saving of electric energy during hot sunny days was about 460 %. It means that for 1 kWh of electrical input to the system, we achieve 4.6 kWh. This percentage decreases as the evaporator temperature decreases and is a function of solar energy input. (Author)

  20. Fundamentals about the development of the electricity supply in Germany. Challenges to a municipal power company; Grundsaetzliches zur Entwicklung der Stromversorgung in Deutschland. Herausforderungen an einen staedtischen Stromnetzbetreiber

    Energy Technology Data Exchange (ETDEWEB)

    Graf, Dietrich

    2016-08-01

    The roles of the different types of operators are described and particularly pointed out the duties of a municipal system operator to various examples. The implementation of the energy transition will require a fundamental change in behaviour of the customers. The possibilities of the network operator will be essentially limited to the stimulation of this change in behaviour through information and transparency. Attention is drawn to the unique, publicly accessible portal that the production and consumption situation in Hamburg is transparent in real time showing at district level.

  1. Perceptions of informal settlement residents on water supply and sanitation : the case of Boiketlong in Emfuleni Local Municipality / Cornelius Tsotang Musa

    OpenAIRE

    Musa, Cornelius Tsotang

    2014-01-01

    Informal settlements in South Africa face common challenges of inadequate services delivery or none. The basic services which most informal settlement residents need for survival are water supply and sanitation. The state of affairs in informal settlements with regard to water supply and sanitation is that the infrastructure for such services is of poor quality, and requires urgent improvement in order to meet international standards. In many informal settlements people still travel long d...

  2. Energy, economy and exergy evaluations of the solutions for supplying domestic hot water from low-temperature district heating in Denmark

    International Nuclear Information System (INIS)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    Highlights: • Provided domestic hot water configurations for low-temperature district heating. • Various building typologies and district heating supply temperatures were included. • Different scenarios were evaluated from the energy, economy and exergy aspects. • The benefits of lower return temperature to district heating were investigated. - Abstract: District heating in Denmark is going through the transition from 3rd generation (80/40 °C) to 4th generation (50–55 °C/25 °C) systems in preparation for district heating based completely on renewable fuels by 2035. However, concern about Legionella growth and reduced comfort with low-temperature domestic hot water supply may be discouraging the implementation of low-temperature district heating. Aimed at providing possible solutions, this study modelled various proposals for district heating systems with supply temperatures of 65 °C, 50 °C and 35 °C and for two different building topologies. Evaluation models were built to investigate the energy, economy and exergy performances of the proposed domestic hot water systems in various configurations. The configurations of the devised domestic hot water substations were optimised to fit well with both low and ultra-low-temperature district heating and to reduce the return temperature to district heating. The benefits of lower return temperatures were also analysed compared with the current district heating situation. The evaluation results show that the decentralized substation system with instantaneous heat exchanger unit performed better under the 65 °C and 50 °C district heating scenarios, while the individual micro tank solution consumed less energy and cost less in the 35 °C district heating scenario.

  3. Energy, economy and exergy evaluations of the solutions for supplying domestic hot water from low-temperature district heating in Denmark

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    District heating in Denmark is going through the transition from 3rd generation (80/40 °C) to 4th generation (50-55 °C/25 °C) systems in,preparation for district heating based completely on renewable fuels by 2035. However, concern about Legionella growth and reduced comfort with low......-temperature domestic hot water supply may be discouraging the implementation of low-temperature district heating. Aimed at providing possible solutions, this study modelled various proposals for district heating systems with supply temperatures of 65 °C, 50 °C and 35 °C and for two different building topologies....... Evaluation models were built to investigate the energy, economy and exergy performances of the proposed domestic hot water systems in various configurations. The configurations of the devised domestic hot water substations were optimised to fit well with both low and ultra-low-temperature district heating...

  4. Electricity and heat supply of a settlement at different standards of energy efficiency; Strom- und Waermeversorgung einer Siedlung bei unterschiedlichen Energieeffizienz-Standards

    Energy Technology Data Exchange (ETDEWEB)

    Schuberth, Jens; Tschetschorke, Katja

    2013-07-15

    The underlying study analyses the ecologic impact and the economic efficiency of several conventional and innovative heat supply systems to provide a quarter heat for space and water heating and electricity for residential and commercial application and for street lighting. Retrofits of buildings change the ratio of demands for electricity and heat. The demand for heat decreases more than the demand for electricity, and the share of distribution losses in heat grids rises. The question is if it is still economically efficient to build or extend local and long-distance district heating networks. Demands for final and primary energy, greenhouse gas emissions and costs (for operation, energy consumption and investments) of the different systems are compared and rated both in charts and tables. A sensitivity analysis includes increasing energy purchasing costs and assesses the possible economic efficiency of the supply systems in future. Another sensitivity analysis estimates how the climate impact of the supply systems for heat and electricity changes if electricity generation becomes less harmful for climate. Additionally, costs for environmental damage - so-called external costs - are internalised in the analysis of economic efficiency. In an overall rating ecologic and economically efficient systems are recommended.

  5. Development and Evaluation of Control System for Microgrid Supplying Heat and Electricity

    Science.gov (United States)

    Kojima, Yasuhiro; Koshio, Masanobu; Nakamura, Shizuka

    Photovoltaic (PV) and Wind Turbine (WT) generation systems are expected to offer solutions to reduce green house gases and become more widely used in the future. However, the chief technical drawback of using these kinds of weather-dependent generators is the difficulty of forecasting their output, which can have negative impacts on commercial grids if a large number of them are introduced. Thus, this problem may hinder the wider application of PV and WT generation systems. The Regional Power Grid with Renewable Energy Resources Project was launched to seek a solution to this problem. The scope of the project is to develop, operate, and evaluate a Dispersed Renewable Energy Supply System with the ability to adapt the total energy output in response to changes in weather and demand. Such a system would reduce the impact that PV and WT generation systems have on commercial grids and allow the interconnection of more Dispersed Energy Resources (DER). In other words, the main objective of this project is to demonstrate an integrated energy management system, or a type of microgrid [1], as a new way of introducing DERs. The system has been in operation since October 2005 and will continue operation until March 2008. Through the project period, the data on power quality, system efficiency, operation cost, and environmental burden will be gathered and a cost-benefit analysis of the system will be undertaken. In this paper, firstly we introduce the concept of microgrid for reducing negative impact of natural energy, and secondly illustrate the structure of electric and thermal supply control system for Microgrid, especially for the Hachinohe demonstration project. The control system consists of four stages; weekly operation planning, economic dispatching control, tie-line control and local frequency control. And finally demonstration results and evaluation results are shown.

  6. Heat transfer models for predicting Salmonella enteritidis in shell eggs through supply chain distribution.

    Science.gov (United States)

    Almonacid, S; Simpson, R; Teixeira, A

    2007-11-01

    Egg and egg preparations are important vehicles for Salmonella enteritidis infections. The influence of time-temperature becomes important when the presence of this organism is found in commercial shell eggs. A computer-aided mathematical model was validated to estimate surface and interior temperature of shell eggs under variable ambient and refrigerated storage temperature. A risk assessment of S. enteritidis based on the use of this model, coupled with S. enteritidis kinetics, has already been reported in a companion paper published earlier in JFS. The model considered the actual geometry and composition of shell eggs and was solved by numerical techniques (finite differences and finite elements). Parameters of interest such as local (h) and global (U) heat transfer coefficient, thermal conductivity, and apparent volumetric specific heat were estimated by an inverse procedure from experimental temperature measurement. In order to assess the error in predicting microbial population growth, theoretical and experimental temperatures were applied to a S. enteritidis growth model taken from the literature. Errors between values of microbial population growth calculated from model predicted compared with experimentally measured temperatures were satisfactorily low: 1.1% and 0.8% for the finite difference and finite element model, respectively.

  7. Improving the efficiency of heat supply systems on the basis of plants operating on organic Rankine cycle

    Science.gov (United States)

    Solomin, I. N.; Daminov, A. Z.; Sadykov, R. A.

    2017-11-01

    Results of experimental and analytical studies of the plant main element - plant turbomachine (turbo-expander) operating on organic Rankine cycle were obtained for facilities of the heat supply systems of small-scale power generation. At simultaneous mathematical modeling and experimental studies it was found that the best working medium to be used in the turbomachines of these plants is Freon R245fa which has the most suitable calorimetric properties to be used in the cycle. The mathematical model of gas flow in the turbomachine was developed. The main engineering dependencies to calculate the optimal design parameters of the turbomachine were obtained. The engineering problems of providing the minimum axial size of the turbomachine impeller were solved and the main design elements were unified.

  8. Renewable municipal waste barometer

    International Nuclear Information System (INIS)

    2014-01-01

    In the European Union the production of primary energy from the incineration of municipal waste increased by only 0.7% in 2013 and reached 8.7 million tep (tonnes of oil equivalent). Germany ranks first with the production of 2729 ktep followed by France with 1246 ktep. A positive point is that the sale of heat to heat networks has strongly increased in some countries which means that primary energy is better used. 2 tables give the production of electricity and heat from the incineration of municipal waste in the E.U. member states in 2012 and 2013. Germany ranks first in the 2 tables. The total production of electricity and heat from the incineration of municipal waste in E.U. in 2013 reached 18741 GWh and 2361 tep respectively. A list reviews the most significant companies working in Europe in the sector of waste incineration, 8 companies are listed, 2 are German: EEW, Remondis, 3 are French: SITA (Suez Environment, Veolia and TIRU (EDF), Urbaser is spanish, Gruppo Hera is Italian and AEB-Amsterdan is dutch. (A.C.)

  9. Comparative study of ageing, heat treatment and accelerated carbonation for stabilization of municipal solid waste incineration bottom ash in view of reducing regulated heavy metal/metalloid leaching.

    Science.gov (United States)

    Santos, Rafael M; Mertens, Gilles; Salman, Muhammad; Cizer, Özlem; Van Gerven, Tom

    2013-10-15

    This study compared the performance of four different approaches for stabilization of regulated heavy metal and metalloid leaching from municipal solid waste incineration bottom ash (MSWI-BA): (i) short term (three months) heap ageing, (ii) heat treatment, (iii) accelerated moist carbonation, and (iv) accelerated pressurized slurry carbonation. Two distinct types of MSWI-BA were tested in this study: one originating from a moving-grate furnace incineration operation treating exclusively household refuse (sample B), and another originating from a fluid-bed furnace incineration operation that treats a mixture of household and light industrial wastes (sample F). The most abundant elements in the ashes were Si (20-27 wt.%) and Ca (16-19 wt.%), followed by significant quantities of Fe, Al, Na, S, K, Mg, Ti, and Cl. The main crystalline substances present in the fresh ashes were Quartz, Calcite, Apatite, Anhydrite and Gehlenite, while the amorphous fraction ranged from 56 to 73 wt.%. The leaching values of all samples were compared to the Flemish (NEN 7343) and the Walloon (DIN 38414) regulations from Belgium. Batch leaching of the fresh ashes at natural pH showed that seven elements exceeded at least one regulatory limit (Ba, Cr, Cu, Mo, Pb, Se and Zn), and that both ashes had excess basicity (pH > 12). Accelerated carbonation achieved significant reduction in ash basicity (9.3-9.9); lower than ageing (10.5-12.2) and heat treatment (11.1-12.1). For sample B, there was little distinction between the leaching results of ageing and accelerated carbonation with respect to regulatory limits; however carbonation achieved comparatively lower leaching levels. Heat treatment was especially detrimental to the leaching of Cr. For sample F, ageing was ineffective and heat treatment had marginally better results, while accelerated carbonation delivered the most effective performance, with slurry carbonation meeting all DIN limits. Slurry carbonation was deemed the most

  10. Chemical and physical properties of cyclone fly ash from the grate-fired boiler incinerating forest residues at a small municipal district heating plant (6MW).

    Science.gov (United States)

    Pöykiö, R; Rönkkömäki, H; Nurmesniemi, H; Perämäki, P; Popov, K; Välimäki, I; Tuomi, T

    2009-03-15

    In Finland, the new limit values for maximal allowable heavy metal concentrations for materials used as an earth construction agent came into force in July 2006. These limit values are applied if ash is utilized, e.g. in roads, cycling paths, pavements, car parks, sport fields, etc. In this study we have determined the most important chemical and physical properties of the cyclone fly ash originating from the grate-fired boiler incinerating forest residues (i.e. wood chips, sawdust and bark) at a small municipal district heating plant (6 MW), Northern Finland. This study clearly shows that elements are enriched in cyclone fly ash, since the total element concentrations in the cyclone fly ash were within 0.2-10 times higher than those in the bottom ash. The total concentrations of Cd (25 mg kg(-1); d.w.), Zn (3630 mg kg(-1); d.w.), Ba (4260 mg kg(-1); d.w.) and Hg (1.7 mg kg(-1); d.w.) exceeded the limit values, and therefore the cyclone fly ash cannot be used as an earth construction agent. According to the leached amounts of Cr (38 mg kg(-1); d.w.), Zn (51 mg kg(-1); d.w.) and sulphate (50,000 mg kg(-1); d.w.), the cyclone fly ash is classified as a hazardous waste, and it has to be deposited in a hazardous waste landfill.

  11. SOLID FUEL OF HYDROCARBON, WOOD AND AGRICULTURAL WASTE FOR LOCAL HEAT SUPPLY SYSTEMS

    Directory of Open Access Journals (Sweden)

    B. M. Khroustalev

    2017-01-01

    Full Text Available In Belarus oil refining and oil producing industries are paid close attention. On the background of the active maintaining the level of oil processing and volume of oil extraction in our country and in the countries of the Eurasian Economic Union there is a steady formation of hydrocarbon-containing waste; therefore recycling of the latter is an urgent task to improve the competitiveness of production. The most cost-effective way of using hydrocarbon waste is the conversion of it into power resources. In this case it is possible to obtain significant power-saving and economic effect of the combined use of a hydrocarbon, wood, agricultural and other combustible waste, meanwhile improving the ecological situation at the sites of waste storage and creating a solid fuel with the necessary energy and specified physical-and-chemical properties. A comprehensive solution of a recycling problem makes it possible to use as energy resources a lot of waste that has not found application in other technologies, to produce alternative multi-component fuel which structure meets environmental and energy requirement for local heating systems. In addition, the implementation of such technology will make it possible to reduce power consumption of enterprises of various kinds that consume fuel and will also increase the share of local fuels in the energy balance of a particular region.

  12. Municipal responses to the energy challenge: Nysted, Denmark. Innovation and retreat in a rural municipality

    Energy Technology Data Exchange (ETDEWEB)

    Woodward, A E

    1985-01-01

    This case study is one of a series describing the social and organizational processes behind municipal innovation in energy planning, conservation and supply. Nysted in Denmark provides an example of both the potential and the limitations on innovation in energy in a small-town environment. The community sponsored an innovative planning project which has since become a model for Danish community energy inventory studies and planning. Further, many individuals in Nysted adapted their heating or electrical supply systems for the use of renewable fuels, especially wind and straw. The community relied on outside expertise and was confronted with the classic problem of transition and implementation when the consultants left. Nysted amply illustrates the dilemma of small communities faced with modern technological problems and limited technological resources.

  13. Survey report of year 2000 version. Feasibility study on energy efficiency/conservation, and environmental improvement of district heat and electricity supply station Radom City

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In order to promote the COP3 joint implementation, discussions were given on the district heat and electricity supply station in Radom City in Poland. Power capacity utilized above a certain level will be generated by cogeneration power plants according to the annual heat supply load patterns, and insufficient capacity will be supplied from the existing hot water boilers during winter when thermal load is high. Daily load variation will be handled by installing auxiliary combustion facilities of 20% of the full capacity. The power plants will be of natural gas burning gas-turbine cogeneration plants, and hot water will be supplied from the modified waste heat boilers. The cogeneration power plants will be capable of taking care of 80% of the annual supply quantity of heat. The heat supply capacity will be 72 MWt including the auxiliary combustion, and the electric power generation capacity will be 35 MWe. Improvement in thermal efficiency to 80% or higher will reduce coal consumption, resulting in saving of 28,117 toe/year after subtracting the increase in natural gas consumption. Reduction in CO2 emission will also be as large as 206,000 tons/year, causing air pollutants to be also reduced. Assuming the facility cost of 4,336 billion yen to be taken care by the Japanese environmental yen loan, the Polish National Fund loan, and the independent fund of the city of Radom, the IRRON investment over the operation period of 30 years is considerably good at 10%. The investment can be recovered in nine years, and the cash flow will have no problems. (NEDO)

  14. 100% energy supply coverage with renewable energy. Requirements for its implementation at the global, national and municipal level; 100%-Versorgung mit erneuerbaren Energien. Bedingungen fuer eine globale, nationale und kommunale Umsetzung

    Energy Technology Data Exchange (ETDEWEB)

    Rogall, Holger

    2014-07-01

    This book presents itself as a systematic, easily understandable introduction into the requirements for an energy supply based 100% on renewable energy. Its main focus is on the strategic paths that must be followed for this purpose in the realms of business, technology and governmental policy. It highlights the opportunities and impediments on the way, analysing in the process the roles of political, economic and civil society players from the global down to the municipal level. Starting out from the present state of discussion on the German energy transition it investigates the strengths and weak points of efficiency technologies and renewable energies available today and elaborates a strategic path for developing the necessary infrastructure. In awareness of the fact that 100% coverage will not come about from market mechanisms alone it explores the ecological crash barriers that need to be set up in addition. This is followed by chapters on the roles, interests and means of those players who can exert influence on the framing of the relevant political and legal instruments as well as their means of pursuing their interests. The book thus contributes to clarifying the possibilities of and impediments to achieving an energy supply system based 100% on renewable energy.

  15. Longevity characteristics of flat solar water-heating collectors in hot-water-supply systems. Part 1. Procedure for calculating collector thermal output

    International Nuclear Information System (INIS)

    Avezova, N.R.; Ruziev, O. S.; Suleimanov, Sh. I.; Avezov, R. R.; Vakhidov, A.

    2013-01-01

    A procedure for calculating longevity indices (daily and monthly variations and, hence, annual thermal output) of flat solar water-heating collectors, amount of conditional fuel saved per year by using solar energy, and cost of solar fuel and thermal energy generated in hot-water-supply systems is described. (authors)

  16. FY1999 Meeting of The Society of Heating, Air-Conditioning and Sanitary Engineering of Japan. Hot water supply system; 1999 nendo gakujutsu koenkai gaiyo. Kyuto

    Energy Technology Data Exchange (ETDEWEB)

    Oze, H. [Toyo University, Tokyo (Japan)

    1999-12-05

    G-5 and 6 measure and investigate actual state of use of hot water supply systems in dormitories used by persons living alone without their families and by unmarried persons to collect fundamental data. G-5 considers how hot water is used, by making a questionnaire survey on the subject houses, and identifies the consumption trend of heat, water and hot water in the hot water supply systems as a whole. G-6 selected eleven houses from among the houses discussed in the previous report to identify the trend of use of hot water by each house. Also, quantity of hot water used in every day of the week is estimated. G-7 discusses methods for estimating water temperatures at faucets of water pipes from the water sources. This is intended to raise the accuracy of tap water temperature conversion coefficient by districts used for calculating estimated heat quantity as a parameter 'hot water supply energy consumption coefficient' to evaluate energy saving performance of a hot water supply facility. G-8 performs numerical simulations changing different parameters in the hot water supply piping system by using a heat loss calculation model for the existing household hot water supply piping. It executes evaluation on energy conservation performance of each model. G-9 estimates efficiency of instantaneous household gas hot water supply devices, not only on thermal efficiency of devices during steady state combustion, but also on non-steady state such as start-up, and discusses methods to derive actual efficiency by using calculations. (translated by NEDO)

  17. Proposal for the award of a contract for the supply of bake-out heating jackets for the LHC vacuum components

    CERN Document Server

    2006-01-01

    This document concerns the award of a contract for the supply of bake-out heating jackets for the LHC vacuum components. The Finance Committee is invited to agree to the negotiation of a contract with ELTHERM (DE), the lowest bidder, for the supply of heating jackets for a total amount of 711 567 euros (1 120 646 Swiss francs), not subject to revision, with an option for up to 15% additional heating jackets for an additional amount of up to 106 735 euros (168 097 Swiss francs), not subject to revision, bringing the total amount to 818 302 euros (1 288 743 Swiss francs), not subject to revision. The amounts in Swiss francs have been calculated using the present rate of exchange. 2006/68/5/e

  18. Line voltage distortions due to operation of the power supply devices required for plasma heating and magnetic field generation in the W7X thermonuclear fusion experiment

    International Nuclear Information System (INIS)

    Werner, F.

    1997-03-01

    The operation of the W7-X plasma heating devices requires high voltage DC power supplies with a total electrical power of 40 MVA. For this purpose twelve-pulse AC/DC converters are projected. These converters enforce a non sinusoidal line current, whose harmonics are causing corresponding line voltage distortions. To evaluate the extent of these distortions, the reaction of the harmonic currents on the AC line, is investigated by numerical network analysis. This is done for both, the 20 kV-junction point of the converters and the 110 kV-line terminal of the electricity supply company. Furthermore the design of LC series-resonant circuits, projected for power factor correction and damping of the harmonic content of the line voltage, has been verified. The additional operation of the 1.5 MVA magnet power supplies also contributes, even though to a much smaller extent, to the line voltage distortion. The influence of these twelve-pulse AC/DC converters was investigated too. The numerical calculations have been done with the aid of the network simulation program 'Pspice'. In an equivalent circuit the transmission line network and the transformers are represented by their inductances respectively equivalent inductances. The rectifier units are simulated by a number of current sources, producing the current harmonics in amplitude, frequency and phase. The harmonics amplitudes of the plasma heating power supplies are frequency and phase. The harmonics amplitudes of the plasma heating power supplies are measured values given by the manufacturer. For the magnet power supplies, the harmonics are derived from the theoretical step like I(t) current shape by Fourier series decomposition. Due to the action of the LC circuits the achieved characteristic voltage quality values are far below the permissible values corresponding to the recommendations of VDE 0160. (orig.) [de

  19. Swedish district heating - owners, prices and profitability

    International Nuclear Information System (INIS)

    Andersson, Sofie; Werner, S.

    2001-01-01

    Owners, prices and profitability are examined in this report for 152 Swedish district heating companies during 1999. Only public information available has been used: Prices from a national annual consumer study, energy supplied, lengths of district heating pipes installed, and average prices for energy supplied. These companies are responsible for 96 % of all district heat supplied in Sweden. District heating systems owned by municipalities were responsible for 65 % of all district heat supply, while the share of power companies was 34 %. Other private owners accounted for 1 %. Only 12 % of the board members are women and more than 40 % of the companies have no woman in the board. The prices gathered by the annual consumer study are good estimates of the price level of district heating in Sweden. The average revenues are only 4,1 % lower than the effective average of prices gathered. Price of district heating decrease with size and market share. Use of combined heat and power plants decrease prices slightly. Lower prices with size can mainly be explained by lower energy supply costs. Calculated rates of return in relation to calculated replacement values increase slightly by size and are almost independent of age and market share. The purport of these conclusions is that the district heating companies share the cost reduction from size with their customers, while the whole benefit from high market shares is repaid to the customers. Calculated rates of return vary among the owner groups examined. Lower rates are accepted by municipalities, while power companies have higher rates at the average costs used. Total replacement costs for the 152 companies has been estimated to 89 billion Swedish crowns or 10 billion Euro. Only correlation analyses using one dimension have been used in this study. A higher degree of quality can be obtained by using multi-dimensional analyses

  20. Changes in heat load profile of typical Danish multi-storey buildings when energy-renovated and supplied with low-temperature district heating

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, Svend

    2013-01-01

    end-use savings are implemented in buildings concurrent with the application of low-temperature district heating (LTDH), the heat profiles of the buildings will change. Reducing peak loads is important, since this is the dimensioning foundation for future district heating systems. To avoid oversized...

  1. MULTI-HEAT SOURCE SOLAR HEAT PUMP HEAT SUPPLY SYSTEM AND PERFORMANCE SIMULATION%复合热源太阳能热泵供热系统及其性能模拟

    Institute of Scientific and Technical Information of China (English)

    杨磊; 张小松

    2011-01-01

    提出了一种复合热源太阳能热泵供热系统,通过阀门切换,可根据不同的天气状况改变运行模式,以空气和太阳辐射作为热源制取供暖用水.针对所设计的lOkw供热系统,建立了系统的数学模型,对热泵串联集热器(SC+HP)及集热器串联热泵(HP+SC)两种运行模式下的循环性能进行了计算机模拟分析,并计算了系统的全年运行状况.从模拟结果可以看出,在模拟进水温度区间内,HP+SC模式下热泵COP较高,最高比SC+HP模式高2.58%;而SC+HP模式集热器热性能较好,总热效率更高,最高比HP+SC模式高2.62%.%A compound solar heat pump heat supply system was presented. The system can make heating water from air source and solar radiation by valve switching, based on different weather conditions. A numerical model for a l0kW heating utilizing was established. The circulation performances of solar collector with heat pump( SC + HP) and heat pump with solar collector( Hp + SC) operation modes were simulated. The all year round operation status was also caculated.The results have shown that the COP of HP + SC mode is at most 2.58 % higher than SC + HP mode in simulation water temperature range. But the latter has a better collector thermal performance and overall thermal efficiency is at most 2.62 % higher than the former.

  2. Seon heats with geothermal energy

    International Nuclear Information System (INIS)

    Hawkins, A.C.

    2001-01-01

    This article describes the combined use of ground water for the supply of drinking water for the municipality of Seon, Switzerland and as the basis for a district heating system. The use of the water, pumped up from a depth of 300 meters and exhibiting a temperature of 19.5 o C, as the heat source for heat pumps is described. The history of the project is discussed and figures are given on the district heating system that provides heat for an indoor swimming pool complex, industry and living accommodation in the village. Operational strategies used to make optimum use of tariff structures are described. The role played by local initiative in this innovative project is emphasised

  3. Heat contracting - a contribution to climate protection, security of supply and competition; Waerme-Contracting - ein Beitrag zu Klimaschutz, Versorgungssicherheit und Wettbewerb

    Energy Technology Data Exchange (ETDEWEB)

    Quint, R.P. [GASAG WaermeService GmbH, Berlin (Germany)

    2007-08-15

    Contracting is an important trump card when it comes to containing the climate change and improving the security of supply - and a promising business field besides. This is an option that should be used more widely considering the ambitious energy efficiency improvement targets of the European Union and Germany, which are set at 20% and 50% percent over the year 1990, respectively. It is moreover an option that pays off. German tenancy law is in urgent need of a reform to make heat contracting more popular. Furthermore, the modernisation of heating systems through contracting should be placed on a level with modernisation effected by the landlord.

  4. Exploitation of the geothermal potentials for the heat supply of the capital city; Erschliessung des geothermischen Potenzials fuer die Waermeversorgung der Hauptstadt

    Energy Technology Data Exchange (ETDEWEB)

    Bredel-Schuermann, Stefan [Berliner Gaswerke (GASAG)-AG, Berlin (Germany); Stiller, Manfred; Bauer, Klaus; Ryberg, Trond; Spalek, Angela; Huenges, Ernst [GeoForschungsZentrum Potsdam (Germany)

    2011-10-15

    Renewable energy sources currently are applied for the heat supply of Berlin only to 2%. The supply concept for the CO{sub 2} neutral city quarter at the Gasometer Schoeneberg provides for use of deep geothermal energy. An annual gross heat demand of nearly 7,000 MWh as well as a cooling requirement of nearly 5,000 MWh are expected for the site with scientific institutions, offices and restaurants.With the support of the GFZ German Research Centre for Geosciences (Potsdam, Federal Republic of Germany), the project partners GASAG Berliner Gaswerke Aktiengesellschaft (Berlin, Federal Republic of Germany) and EUREF AG (Berlin, Federal Republic of Germany) have performed first measurements in order to explore the geothermal potential of the capital city.

  5. Theoretical overview of heating power and necessary heating supply temperatures in typical Danish single-family houses from the 1900s

    DEFF Research Database (Denmark)

    Østergaard, Dorte Skaarup; Svendsen, Svend

    2016-01-01

    in typical Danish single-family houses constructed in the 1900s. The study provides a simplified theoretical overview of typical building constructions and standards for the calculation of design heat loss and design heating power in Denmark in the 1900s. The heating power and heating demand in six typical...... Danish single-family houses constructed in the 1900s were estimated based on simple steady-state calculations. We found that the radiators in existing single-family houses should not necessarilrbe expected to be over-dimensioned compared to current design heat loss. However, there is considerable...... potential for using low-temperature space heating in existing single-family houses in typical operation conditions. Older houses were not always found to require higher heating system temperatures than newer houses. We found that when these houses have gone through reasonable energy renovations, most...

  6. Heat supply concept for trade. Vol. 3. Environmentally friendly and energy-saving heat supply for public institutions by private operator models (phase 1). Final report. Vol. 2; Waermelieferungskonzept des Handwerks. Bd. 3. Umweltfreundliche und energiesparende Waermeversorgung oeffentlicher Einrichtungen durch private Betreibermodelle (Phase 1). Abschlussbericht. Berichtsband 2

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, J [ed.; Biermann, J; Locke, R; Meyer, K

    1991-01-01

    Volume 2 of this report indicates two goals: (3): Development and implementation of concrete heat supply models for public facilities in Berlin; (4): Development of models for cooperation between the heat utility and Berlin trade enterprises. (HW) [Deutsch] Der Berichtsband 2 weist 2 Teilziele auf: Teilziel 3: Erarbeitung und Gestaltung konkreter Waermelieferungsmodelle fuer oeffenliche Einrichtungen in Berlin; Teilziel 4: Gestaltung von Kooperationsmoeglichkeiten zwischen Waermeversorgungsgesellschaft und Handwerksbetrieben in Berlin. (HW)

  7. An overview of the photovoltaic, wind power, solar water heating and small-scale hydropower supply industries in South Africa up to 1994/95

    International Nuclear Information System (INIS)

    Stassen, G.; Holm, D.

    1997-01-01

    This paper contains a broad overview of the South African photovoltaic, solar water heating, wind power and small-scale hydropower industries. Against the general lack of a comprehensive national database on renewable energy supply and demand, this overview attempts to provide general background information on these commercial industries, market trends, local sales figures, export volumes and installed capacity estimates. It also identifies the industry's major constraints, as well as their future outlook. (author). 12 refs., 13 tabs., 4 figs

  8. Energetic retrofitting of industrial heat supply systems. Possibilities of enhancing the efficiency and energy conservation at large combustion engineering plants; Energetische Modernisierung industrieller Waermeversorgungssysteme. Moeglichkeiten der Effizienzsteigerung und der Energieeinsparung an grossen feuerungstechnischen Anlagen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-12-15

    In the contribution under consideration, the Deutsche Energie-Agentur GmbH (Berlin, Federal Republic of Germany) reports on an energetic modernization of industrial heat supply systems. Possibilities of an enhancement of the energetic efficiency and energy conservation at large combustion engineering plants are described. After an introduction to this theme, the author of this contribution provides an overview of the optimization of heat supply systems, and reports on the following aspects: Optimisation of the heat demand; energy efficient heat generation; heat recovery; energy efficient conversion technology and generation technology; associate partners for more energy efficiency in industry and commerce; best practice examples.

  9. Power supply in future: ecological aspects

    International Nuclear Information System (INIS)

    Hustedt, M.

    2000-01-01

    The most important prerequisites for an ecological supply of energy in the future is the opting out of nuclear energy and the completion of the second and third phase of the socio-ecological tax reform. As a part of our energy will continue to be generated on the basis of fossil fuels in the foreseeable future, it is essential that a radical change takes place in the efficiency of fossil energy engineering. In addition to this, any possible energy-saving potential must be exploited; this includes the new energy-saving law, promoting the modernisation of old buildings and modern energy management (heat insulation, heating engineering, warm water heating etc.). For an ecological power supply the share of renewable energies must be increased to form a major pillar of our power supply. The '100,000-roof' programme of the German federal government and the development programme for near-market renewable energy sources form part of this approach. Energy research should shift its orientation and accelerate the conversion of our power supply: priority should be given to developing energy-saving technologies and renewable energy. Supporting municipalities and public utilities is especially important. This means revising the basic conditions of energy laws so that they assist public utilities to face competition as power utilities. (orig.) [de

  10. Public Water Supply Systems (PWS)

    Data.gov (United States)

    Kansas Data Access and Support Center — This dataset includes boundaries for most public water supply systems (PWS) in Kansas (525 municipalities, 289 rural water districts and 13 public wholesale water...

  11. Increasing RES Penetration and Security of Energy Supply by Use of Energy Storages and Heat Pumps in Croatian Energy System

    DEFF Research Database (Denmark)

    Krajačić, Goran; Mathiesen, Brian Vad; Duić, Neven

    2010-01-01

    electricity, heat and transport demands, and including renewable energy, power plants, and combined heat and power production (CHP) for district heating. Using the 2007 energy system the wind power share is increased by two energy storage options: Pumped hydro and heat pumps in combination with heat storages....... The results show that such options can enable an increased penetration of wind power. Using pumped hydro storage (PHS) may increase wind power penetration from 0.5 TWh, for existing PHS installations and up to 6 TWh for very large installations. Using large heat pumps and heat storages in combination...... with specific regulation of power system could additionally increase wind penetration for 0.37 TWh. Hence, with the current technologies installed in the Croatian energy system the installed pumped hydro-plant may facilitate more than 10% wind power in the electricity system. Large-scale integration of wind...

  12. Including solar energy in the local heat supply of the Goettingen city works; Einbindung von Sonnenenergie in die Nahwaermeversorgung der Stadtwerke Goettingen AG

    Energy Technology Data Exchange (ETDEWEB)

    Tepe, R. [ISFH - Institut fuer Solarenergieforschung Hameln-Emmerthal GmbH, Emmerthal (Germany); Schreitmueller, K.R. [ISFH - Institut fuer Solarenergieforschung Hameln-Emmerthal GmbH, Emmerthal (Germany); Vanoli, K. [ISFH - Institut fuer Solarenergieforschung Hameln-Emmerthal GmbH, Emmerthal (Germany)

    1996-11-01

    The research project `Solar local heat Goettingen` was started in 1992 in which, by including a 785 m{sup 2} flat collector plant in the return of the local heat supply of the Goettingen City Works; the potential of the combined system of solar plant and conventional heat supply system is to be proved. The size of the collector plant and inclusion in an existing local heat network promised an advantageous combination due to appreciably lower investment costs (lower collector installation costs) and savings in system technique, reduced operating costs, and higher income due to favourable operating conditions with even low collector operating temperatures and reduced piping losses. In parallel with this system, the Goettingen City Works installed an air collector plant which is used to preheat the combustion air taken to the conventional burners. (orig./HW) [Deutsch] Es entstand im Jahr 1992 das Forschungsvorhaben `Solare Nahwaerme Goettingen`, in dem durch die Einbindung einer 785 m{sup 2} grossen Flachkollektoranlage in den Ruecklauf der Nahwaermeversorgung der Stadtwerke Goettingen AG das Potential der Systemkombination Solaranlage und konventionelle Waermeversorgungssystem nachgewiesen werden sollte. Die Groesse der Kollektoranlage sowie die Einbindung in ein bestehendes Nahwaermenetz versprachen eine vorteilhafte Kombination aufgrund - deutlich geringerer Investionskosten (geringe Kollektorinstallationskosten sowie Einsparungen bei der Systemtechnik); - reduzierter Betriebskosten; - hoher Ertraege durch guenstige Betriebsbedingungen wie gleichbleibend niedriger Kollektorbetriebstemperaturen und reduzierter Leitungsverluste. Parallel zu diesem System installierten die Stadtwerke Goettingen AG eine Luftkollektoranlage, die der Vorwaermung der den konventionellen Brennern zugefuehrten Verbrennungsluft dient. (orig./HW)

  13. Realisation of a small hydro power plant in the new water reservoir of the water supply of the San Abbondio municipality; Realizzazione di una microcentrale nel nuovo serbatoio dell'acquedotto del comune di S. Abbondio. Progetto definitivo nuovo serbatoio. Progetto di massima e studio varianti microcentrale

    Energy Technology Data Exchange (ETDEWEB)

    Conti, M.

    2008-12-15

    This report for the Swiss Federal Office of Energy (SFOE) presents the construction project of a new water reservoir including a micro-scale hydro power plant in the drinking-water supply of the municipality of San Abbondio, Switzerland. Following the development of residential areas a new water reservoir located at higher elevation is needed. A former preliminary study had demonstrated the feasibility of a micro-scale hydro power plant in the water supply. The adaptation of the plant design to the new situation is described. Investment cost is estimated and several variants are compared. Recommendations are given to the authorities.

  14. District heating in Switzerland: Giving a survey and studying an example case

    Energy Technology Data Exchange (ETDEWEB)

    Kiss, M; Minder, R

    1981-05-01

    Today it is generally accepted that district-heating has essential adventages in areas which are suitable for it - as opposed to the heating mode which is most widely practiced in Switzerland, i.e. individual oil heating. These advantages shall only be pointed out briefly, here, by mentioning the following key words: economy, exploitation of fuel, safety of supply, and enviromental protection. Principally supporting the expansion of existing district-heating installations or the construction of new ones the authors give their view on the subject concerning the contribution to the total supply of heat which reasonably may be attributed to district-heating; they also give their opinion of the plans of a Swiss municipality as to its energy and district-heating supply.

  15. Techno-economic analysis of using corn stover to supply heat and power to a corn ethanol plant - Part 2: Cost of heat and power generation systems

    International Nuclear Information System (INIS)

    Mani, S.; Sokhansanj, S.; Tagore, S.; Turhollow, A.F.

    2010-01-01

    This paper presents a techno-economic analysis of corn stover fired process heating (PH) and the combined heat and power (CHP) generation systems for a typical corn ethanol plant (ethanol production capacity of 170 dam 3 ). Discounted cash flow method was used to estimate both the capital and operating costs of each system and compared with the existing natural gas fired heating system. Environmental impact assessment of using corn stover, coal and natural gas in the heat and/or power generation systems was also evaluated. Coal fired process heating (PH) system had the lowest annual operating cost due to the low fuel cost, but had the highest environmental and human toxicity impacts. The proposed combined heat and power (CHP) generation system required about 137 Gg of corn stover to generate 9.5 MW of electricity and 52.3 MW of process heat with an overall CHP efficiency of 83.3%. Stover fired CHP system would generate an annual savings of 3.6 M$ with an payback period of 6 y. Economics of the coal fired CHP system was very attractive compared to the stover fired CHP system due to lower fuel cost. But the greenhouse gas emissions per Mg of fuel for the coal fired CHP system was 32 times higher than that of stover fired CHP system. Corn stover fired heat and power generation system for a corn ethanol plant can improve the net energy balance and add environmental benefits to the corn to ethanol biorefinery.

  16. Estimation of efficiency of the heat supply system based on a boiler house and a wind turbine in the northern environment

    Science.gov (United States)

    Bezhan, A. V.; Minin, V. A.

    2017-03-01

    This article describes a methodological approach to defining indoor air temperature in buildings heated by a power supply unit consisting of a boiler house and a wind-driven power plant (WDPP). We discuss a heating option for a residential building in the windy conditions of Murmansk city. We proved that, during the periods of strong wind, a WDPP can partially or fully satisfy the heat demand and sometimes even create a surplus of energy. During low wind weather, almost all loads are handled by the boiler house. We considered a possibility to accumulate the surplus energy obtained from a WDPP during strong wind by increasing the temperature in the whole building up to 25°C and further using the accumulated heat during the lowwind period when indoor air temperature may fall below 20°C. This allows saving organic fuel in the boiler house. We demonstrated how indoor air temperature in the building may change throughout the year when using the surplus energy from the WDPP due to thermal storage capacitance of the building. We also provided the results of study, showing favorable energy-related effects of using a WDPP along with the boiler house. It was determined that engaging a WDPP in fulfilling the diagram of heating loads promotes the decrease in the boiler house's contribution to heat supply by 30 to 50%, and using the surplus energy from the WDPP and thermal storage capacitance of the building allows reducing the contribution of the boiler house by 5-15% more in certain months.

  17. MATHEMATICAL MODELING OF HEAT EXCHANGE IN DIRECT FLAT CHANNELS AND DIRECT ROUND PIPES WITH ROUGH WALLS UNDER THE SYMMETRIC HEAT SUPPLY

    Directory of Open Access Journals (Sweden)

    I E. Lobanov

    2017-01-01

    Full Text Available Objectives. The aim of present work was to carry out mathematical modelling of heat transfer with symmetrical heating in flat channels and round pipes with rough walls.Methods. The calculation was carried out using the L'Hôpital-Bernoulli's method. The solution of the problem of intensified heat transfer in a round tube with rough walls was obtained using the Lyon's integral.Results. Different from existing theories, a methodology of theoretical computational heat transfer determination for flat rough channels and round pipes with rough walls is developed on the basis of the principle of full viscosity superposition in a turbulent boundary layer. The analysis of the calculated heat transfer and hydroresistivity values for flat rough channels and round rough pipes shows that the increase in heat transfer is always less than the corresponding increase in hydraulic resistance, which is a disadvantage as compared to channels with turbulators, with all else being equal. The results of calculating the heat transfer for channels with rough walls in an extended range of determinant parameters, which differ significantly from the corresponding data for the channels with turbulators, determine the level of heat exchange intensification.Conclusion. An increase in the calculated values of the relative average heat transfer Nu/NuGL for flat rough channels and rough pipes with very high values of the relative roughness is significantly contributed by both an increase in the relative roughness height and an increase in the Reynolds number Re. In comparison with empirical dependencies, the main advantage of solutions for averaged heat transfer in rough flat channels and round pipes under symmetrical thermal load obtained according to the developed theory is that they allow the calculation of heat exchange in rough pipes to be made in the case of large and very large relative heights of roughness protrusions, including large Reynolds numbers, typical for pipes

  18. Solar Energy Gain and Space-Heating Energy Supply Analyses for Solid-Wall Dwelling Retrofitted with the Experimentally Achievable U-value of Novel Triple Vacuum Glazing

    Directory of Open Access Journals (Sweden)

    Saim Memon

    2017-06-01

    Full Text Available A considerable effort is devoted to devising retrofit solutions for reducing space-heating energy in the domestic sector. Existing UK solid-wall dwellings, which have both heritage values and historic fabric, are being improved but they tend to have meagre thermal performance, partly, due to the heat-loss through glazings. This paper takes comparative analyses approach to envisage space-heating supply required in order to maintain thermal comfort temperatures and attainable solar energy gains to households with the retrofit of an experimentally achievable thermal performance of the fabricated sample of triple vacuum glazing to a UK solid-wall dwelling. 3D dynamic thermal models (timely regimes of heating, occupancy, ventilation and internal heat gains of an externally-insulated solid-wall detached dwelling with a range of existing glazing types along with triple vacuum glazings are modelled. A dramatic decrease of space-heating load and moderate increase of solar gains are resulted with the dwelling of newly achievable triple vacuum glazings (having centre-of-pane U-value of 0.33 Wm-2K-1 compared to conventional glazing types. The space-heating annual cost of single glazed dwellings was minimised to 15.31% (≈USD 90.7 with the retrofit of triple-vacuum glazings. An influence of total heat-loss through the fabric of solid-wall dwelling was analysed with steady-state calculations which indicates a fall of 10.23 % with triple vacuum glazings compared to single glazings.

  19. Fiscal 1974 Sunshine Project result report. Research on solar cooling/heating and hot water supply system; 1974 nendo taiyonetsu reidanbo kyuto system no kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-03-01

    This report describes the fiscal 1974 research result on solar cooling/heating and hot water supply system. This 3- year project from fiscal 1974 to 1976 aims to predict the share of solar energy in future cooling/heating and hot water supply energy demand, and develop simulation technology. The project surveys and analyzes current domestic and overseas development states, and studies various systems to obtain characteristics of every system, pursuit an optimum implementation, and establish a diffusion plan. Future energy consumptions and prices are predicted in relation to energy saving, and the utilization impact of solar energy is analyzed. Study is also made on diffusion plan, profitability and performance evaluation method. Among these schedules, in fiscal 1974 based on the survey and analysis on previous domestic and overseas development states, features and problems were arranged every system and application. The basic study on system simulation, and rough feasibility study on solar heat systems by conventional technique were carried out. The basic data on performance evaluation standards were also prepared. (NEDO)

  20. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

    CERN Document Server

    2012-01-01

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

  1. Communal energy management. Integrated heat supply systems for buildings owned by the city of Altenburg; Kommunales Energiemanagement. Waermeverbundsysteme der Gebaeudeleittechnik der Stadt Altenburg

    Energy Technology Data Exchange (ETDEWEB)

    Paul, A.

    1999-03-01

    The city of Altenburg intended to reduce the investment, energy and operating cost of administrative buildings and schools. Apart from economically efficient power supply, emission reduction was another declared goal. This was achieved by integrated heat supply system and a centralized DDC facility management system. The solution combines high availability with user-friendliness, and the systems reflect the latest state of the art. [Deutsch] Die Stadt Altenburg suchte Wege, die Investitions-, Energie- und Betriebskosten fuer Verwaltungsgebaeude und Schulen zu senken. Neben der wirtschaftlichen Waermeversorgung war ein weiteres Ziel, die hohen Emissionswerte, besonders im inneren Stadtgebiet zu mindern. Die realisierten Waermeverbundsysteme und die zentrale DDC-Gebaeudeleittechnik der Stadt Altenburg gewaehrleisten dies. Die Loesung sichert ausserdem eine hohe Versorgungssicherheit mit Anwendungskomfort. Die Anpassung der Systeme an den jeweiligen Stand der Umweltanforderung und der Technik sind sehr gut gegeben. (orig./MSK)

  2. Design of energy-efficient buildings using interaction between Building Simulation Programme and Energy Supply Simulations for District Heating

    DEFF Research Database (Denmark)

    Christensen, Jørgen Erik; Dalla Rosa, Alessandro; Nagla, Inese

    potential of the energy saving in the society it is very important to address the decisive involvement of the end-users. The human behaviour is the factor that affects the most the energy use in low-energy buildings and should be included in energy simulations. The results can then be linked to programs...... the implementation of C02 neutral communities. A link between a dynamic energy simulation program for buildings and a simulation program for district heating networks is demonstrated. The results of the investigation give an example of how to analyze a community and make recommendations for applying the low...... in a cost-effective way in areas with linear heat densities down to 0.20 MWh/(m.year). Even in cases where the user behaviour is not optimal, the system is able to deliver heat to each customer. The low-energy district heating concept could be strategic for reaching ambitious energy and climate targets...

  3. Effective by combination. Biogas plant Niederweiler supplies two heating grids, directly exploits its electric power commercially and also supplies the balancing energy; Effektiv durch Kombinieren. Biogasanlage Niederweiler versorgt zwei Waermenetze, vermarktet ihren Strom direkt und stellt jetzt auch Regelenergie zur Verfuegung

    Energy Technology Data Exchange (ETDEWEB)

    Lennartz, Marc Wilhelm

    2013-07-01

    In the Eifel (Federal Republic of Germany) an agricultural consortium took over the heat supply of a hotel complex with a satellite cogeneration plant. Thus, the capacity for flexible power feed was set free.

  4. Experience gained in the process of the variable mass heat flow control implemented in the district heat supply system of the city of Gyor

    Energy Technology Data Exchange (ETDEWEB)

    Nagy, F.; Milanovich, L.; Lelek, J.; Kekk, I. [District Heating LTD. of Gyor (Hungary)

    1996-11-01

    The district heating system of the city of Gyor is fed from a hot water boiler plant. The total heat demand for 23,000 residential homes and several public facilities is 260 MW. The variable mass flow control was implemented in 1991 through 1992. Design, preparatory job and the majority of implementation was carried out without external involvement. The paper presents historical background and brief project presentation which is followed by comparative presentation of the variable mass flow control and constant mass flow control. This comparative survey has been conducted on the basis of operating data for 1993 and those for 1988. In the conclusion the gained experience is summarized.

  5. Projecting phase terminated, implementation coming soon. Environment-friendly heat supply at Ruhpolding sports center; Projekt ausgereift - Betreiber gesucht.. Oekologische Waermeversorgung des Ruhpoldinger Sport- und Freizeitzentrums

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2000-02-01

    When the public indoor swimming pool at Ruhpolding was modernized, the community took the chance to convert the whole sports and recreation center (indoor and outdoor swimming pools, skating rink and multi-purpose hall) as well as the school buildings to district heat supply from a biomass-fuelled heating power station. Apart from the financial savings, this solution also reduces exhaust emissions and makes this recreation area mor attractive. [German] Mit der Sanierung und Erweiterung des Wellenhallenbades bietet sich der Gemeinde Ruhpolding die Gelegenheit, die Waermeversorgung des Sport- und Freizeitzentrums (Wellenhallenbad, Freibad, Eissporthalle und Mehrzweckhalle) und der Schulgebaeude von der Einzelversorgung mit Oelkesseln auf die Nahwaermeversorgung mittels Biomasse-Heizwerk umzustellen. Das bringt der Gemeinde nicht nur finanzielle Vorteile, sondern entlastet das Kurgebiet erheblich von schaedlichen Abgasen und erhoeht damit die Attraktivitaet des Erholungsortes. (orig.)

  6. Heat production thanks to waste water; Produire de l'energie grace aux eaux usees

    Energy Technology Data Exchange (ETDEWEB)

    Wellstein, J.

    2009-07-01

    The district heating of a large residential compound in Rheinfelden, Switzerland has been refurbished and extended in order to include new buildings and take advantage of the heat from the municipal waste water treatment plant. The initial system was built in 1976 and delivered heat to 3000 people in 1050 housing units, from three natural gas fired boilers with a total power of 3 MW. In 1993, a study supported by the Swiss Federal Office of Energy identified considerable possible energy savings. Some operational measures were implemented immediately. The recent extension of the district heating to a second residential compound in the neighbourhood increased the heat demand by about 50%. In the course of the planning process it was recognized that waste water from the joint municipal treatment plant of Rheinfelden and Magden - a second city located in the vicinity - has to be cooled by 5 K before being rejected into the Rhine River. This water is now used after filtration as the heat source for two big heat pumps (total 2.5 MW; working fluid: ammonia) supplying the refurbished and extended district heating. Peak heat demand is covered by natural gas boilers (total 9 MW) that can operate alone or in parallel with the heat pumps. Provision has been made to later connect another waste heat source to the district heating network: the municipal skating rink and swimming pool sport facility.

  7. Study of the Effect of Heat Supply on the Hydrodynamics of the Flow and Heat Transfer in Capillary Elements of Mixing Heads Jet Thrusters

    Science.gov (United States)

    Nigodjuk, V. E.; Sulinov, A. V.

    2018-01-01

    The article presents the results of experimental studies of hydrodynamics and those of loobman single-phase and two-phase flows in capillary nozzle elements propellant thrusters and the proposed method of their calculation. An experimental study was performed in capillaries with a sharp entrance edge of the internal diameter of 0.16 and 0.33 mm and a relative length 188 and 161, respectively, in pouring distilled water and acetone in the following range of parameters Reynolds number Re = (0,3 ... 10) · 103, Prandtl number Pr = (2 ... 10), pressure p = (0,1 ... 0,3) MPa, the heat flux q = (0...2)×106 W/m2, the difference of temperature under-heating of liquid Δtn = (5 ... 80)K. The dependences for calculation of single phase boundaries, the undeveloped and the developed surface of the bubble and film key singing of subcooled liquid. It is shown theoretically and experimentally confirmed the virtual absence of areas of undeveloped nucleate boiling in laminar flow. The dependence for calculation of hydraulic resistance and heat transfer in the investigated areas of current. It is shown that in the region of nucleate boiling surface in the flow in capillary tubes, influence of the formed vapor phase on the hydrodynamics and heat transfer substantially higher than in larger diameter pipes.

  8. Development of two-stage compression heat pump for hot water supply in commercial use. Research of compatibility with alternative refrigerant, HFC-134a; Gyomuyo nidan asshukushiki kyuto heat pump no kaihatsu. Daitai reibai HFC-134a no tekiyosei kensho

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, K.; Hasegawa, H.; Saikawa, M.; Iwatsubo, T.; Mimaki, T. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1996-03-01

    Performance of two-stage compression and cascade heating heat pump cycle was evaluated in the case using alternative refrigerant, HFC-134a, instead of CFC-12 through calculations and experiments. Heat source and heat load temperature conditions of CFC-12, HFC-134a, and HCFC-22 were calculated. As a result, this cycle provided equivalent coefficient of performance to use of CFC-12 and HCFC-22. Especially for HFC-134a, discharge gas temperature from compressor was much lower than that of the others, which prevented the heat decomposition of refrigerant. It was found that HFC-134a was suitable refrigerant for high temperature output equipment like this cycle. To grasp the possibility of hot water supply at 65 {degree}C and behavior of lubricating oil which can not be obtained only from calculations, applicability of HFC-134a was investigated. Experiments were conducted using a small test apparatus with electric input of 2 kW. As a result, satisfactory performance was obtained for each evaluation item. Applicability of HFC-134a to the two-stage compression cycle was confirmed. 9 refs., 21 figs., 16 tabs.

  9. Energy supply. Energieversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Eickhof, N.

    1983-01-01

    This anthology presents nine papers dealing with the following subjects: 1) international and national aspects of energy supply, 2) regional and local energy supply concepts, and 3) issues of district-heat supply. Each of the nine papers was entered separately.

  10. Co-flow anode/cathode supply heat exchanger for a solid-oxide fuel cell assembly

    Science.gov (United States)

    Haltiner, Jr., Karl J.; Kelly, Sean M.

    2005-11-22

    In a solid-oxide fuel cell assembly, a co-flow heat exchanger is provided in the flow paths of the reformate gas and the cathode air ahead of the fuel cell stack, the reformate gas being on one side of the exchanger and the cathode air being on the other. The reformate gas is at a substantially higher temperature than is desired in the stack, and the cathode gas is substantially cooler than desired. In the co-flow heat exchanger, the temperatures of the reformate and cathode streams converge to nearly the same temperature at the outlet of the exchanger. Preferably, the heat exchanger is formed within an integrated component manifold (ICM) for a solid-oxide fuel cell assembly.

  11. Bio-charcoal production from municipal organic solid wastes

    Science.gov (United States)

    AlKhayat, Z. Q.

    2017-08-01

    The economic and environmental problems of handling the increasingly huge amounts of urban and/or suburban organic municipal solid wastes MSW, from collection to end disposal, in addition to the big fluctuations in power supply and other energy form costs for the various civilian needs, is studied for Baghdad city, the ancient and glamorous capital of Iraq, and a simple control device is suggested, built and tested by carbonizing these dried organic wastes in simple environment friendly bio-reactor in order to produce low pollution potential, economical and local charcoal capsules that might be useful for heating, cooking and other municipal uses. That is in addition to the solve of solid wastes management problem which involves huge human and financial resources and causes many lethal health and environmental problems. Leftovers of different social level residential campuses were collected, classified for organic materials then dried in order to be supplied into the bio-reactor, in which it is burnt and then mixed with small amounts of sugar sucrose that is extracted from Iraqi planted sugar cane, to produce well shaped charcoal capsules. The burning process is smoke free as the closed burner’s exhaust pipe is buried 1m underground hole, in order to use the subsurface soil as natural gas filter. This process has proved an excellent performance of handling about 120kg/day of classified MSW, producing about 80-100 kg of charcoal capsules, by the use of 200 l reactor volume.

  12. Heat supply concept for trade. Vol. 3. Environmentally friendly and energy-saving heat supply for public institutions by private operator models (phase 1). Final report. Vol. 1; Waermelieferungskonzept des Handwerks. Bd. 3. Umweltfreundliche und energiesparende Waermeversorgung oeffentlicher Einrichtungen durch private Betreibermodelle (Phase 1). Abschlussbericht. Berichtsband 1

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, J [ed.; Biermann, J; Koehler, U; Locke, R; Meyer, K

    1993-12-31

    Volume 1 of the report indicates two goals: (1): Investigation of the boundary conditions for heat supply models, using the example of the states of Berlin (West) and Niedersachsen. (2): Investigation of the available potential in Berlin (West). (HW) [Deutsch] Der Berichtsband 1 weist 2 Teilziele auf: Teilziel 1: Untersuchung der Rahmenbedingungen fuer Waermelieferungsmodelle am Beispiel des Stadtstaates Berlin (West) und des Flaechenstaates Niedersachsen. Teilziel 2: Potentialermittlung in Berlin (West). (HW)

  13. A New Reliability Analysis Model of the Chegongzhuang Heat-Supplying Tunnel Structure Considering the Coupling of Pipeline Thrust and Thermal Effect

    Directory of Open Access Journals (Sweden)

    Jiawen Zhang

    2018-02-01

    Full Text Available Based on the operating Chegongzhuang heat-supplying tunnel in Beijing, the reliability of its lining structure under the action of large thrust and thermal effect is studied. According to the characteristics of a heat-supplying tunnel service, a three-dimensional numerical analysis model was established based on the mechanical tests on the in-situ specimens. The stress and strain of the tunnel structure were obtained before and after the operation. Compared with the field monitoring data, the rationality of the model was verified. After extracting the internal force of the lining structure, the improved method of subset simulation was proposed as the performance function to calculate the reliability of the main control section of the tunnel. In contrast to the traditional calculation method, the analytic relationship between the sample numbers in the subset simulation method and Monte Carlo method was given. The results indicate that the lining structure is greatly influenced by coupling in the range of six meters from the fixed brackets, especially the tunnel floor. The improved subset simulation method can greatly save computation time and improve computational efficiency under the premise of ensuring the accuracy of calculation. It is suitable for the reliability calculation of tunnel engineering, because “the lower the probability, the more efficient the calculation.”

  14. Geothermal use of the Wiesbaden thermal water with high minerals content for heat base load supply of the town hall and affiliated buildings. Geothermische Nutzung des hochmineralisierten Wiesbadener Thermalwassers fuer die Grundlastwaermedeckung des Rathauses und angeschlossener Baulichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Riedle, K.

    1991-10-01

    Within the framework of the large-scale renovation of the spa center Wiesbaden also heat base load supply of all heat consumers is realized with extracted thermal energy. As the thermal water has a high mineral content a delivery method has to be used, which avoids incrustations in form of calcareous sediments, sulphur sludges and iron ochre as well as the escape of the well gas CO{sub 2} and the diffusion of atmospheric oxygene that has an oxidative effect. For this purpose a closed system is used with which the water is drawn off, delivered, stored and distributed. In the second part of the report the heat supply system of the town hall is presented which consists of a direct heat exchange system of thermal water, of residual thermal heat utilization with heat pumps, a cogeneration system as well as of gas boilers to cover peak loads. (BWI).

  15. An analysis of Water Supply Heat Pump's Capability of Energy Storage and Energy Saving Using Electricity%水源热泵系统蓄能节能的可行性

    Institute of Scientific and Technical Information of China (English)

    吴薇; 张小松

    2002-01-01

    In this paper, the characteristic of water supply heat pump (WLHP) is introduced. The thermal performanceand effect of energy saving that can be used to heating and cooling at the same time (the distinctive working mode) is em-phasized. A new idea of heat input using wave trough electricity instead of boilers is brought up, the effect and significance ofthis new method is discussed.

  16. European municipalities and the liberalized energy market

    International Nuclear Information System (INIS)

    2002-04-01

    Municipalities are directly affected by the liberalization of the energy markets. Because they all consume or even produce energy, whether it be for their own consumption or to resell it, they often distribute gas, electricity or heat, they plan urban areas and organize the energy networks on their territory, while in addition citizens expect municipalities to inform them and even protect them against the possible excesses of energy salesmen. Elected representatives administrations, local agencies, municipal companies, citizens' associations etc., all have to innovate. This supplement to Energie-Cites INFO is intended to provide you with practical information and further analyses of the liberalization process. (authors)

  17. Control of supply temperature

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, H; Nielsen, T S; Soegaard, H T

    1996-09-01

    For many district heating systems, e.g. the system in Hoeje Taastrup, it is desirable to minimize the supply temperature from the heat production unit(s). Lower supply temperature implies lower costs in connection with the production and distribution of heat. Factors having impact on the heat demand are for instance solar radiation, wind speed, wind direction and a climate independent part, which is a function of the time of the day/week/year. By applying an optimization strategy, which minimizes the supply temperature, it is assumed that optimal economical operation can be obtained by minimizing the supply temperature and thereby the heat losses in the system. The models and methods described in this report take such aspects into account, and can therefore be used as elements in a more efficient minimization of the supply temperature. The theoretical part of this report describes models and methods for optimal on-line control of the supply temperature in district heating systems. Some of the models and methods have been implemented - or are going to be implemented - in the computer program PRESS which is a tool for optimal control of supply temperature and forecasting of heat demand in district heating systems. The principles for using transfer function models are briefly described. The ordinary generalized predictive control (OGPC) method is reviewed, and several extensions of this method are suggested. New controller, which is called the extended generalized predictive controller (XGPC), is described. (EG) 57 refs.

  18. Development of two-stage compression heat pump for hot water supply in commercial use. Establishment of design method for water and air heat source system; Gyomuyo nidan asshukushiki kyuto heat pump no kaihatsu. Suinetguen oyobi kuki netsugen sytem no sekkei hoho no kakuritsu

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, H; Hashimoto, K; Saikawa, M; Iwatsubo, T; Mimaki, T [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1996-07-01

    The two-stage compression cascade heating heat pump cycle was devised for hot water supply in business use such as hotel and store use which allows hot water supply less in primary energy consumption than gas boilers, and higher in temperature than conventional heat pumps. This cycle heats water in cascade manner by two-stage compression using two compressors in both low- and high-stage refrigerant circuits, and two condensers different in condensation temperature (intermediate heat exchanger and condenser) to achieve higher hot water temperature and higher COP. For cost reduction, the new system design method was established which is possible to cope with conventional compressors such as screw and scroll ones with different theoretical suction volume for every one. System design parameters such as thermal output and COP of hot water supply were largely affected by theoretical suction volume ratio of low- and high-stage compressors dependent on combination of the compressors, and refrigerant condensing temperature in an intermediate heat exchanger as proper parameter. 4 refs., 17 figs., 13 tabs.

  19. Effect of supply air temperature on air distribution in a room with radiant heating and mechanical ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Zhao, Jianing; Fang, Lei

    2017-01-01

    and the horizontal distribution of containment concentration in the breathing zone were measured as the supply air temperature ranged from 15.0°C (59°F)to 19.0°C (66.2°F). The results showed that the vertical air temperature differences were less than 0.3°C (32.5°F) with FH+MV or CH+MV and between 1.9°C (35.4°F...

  20. Diagnostic information system dynamics in the evaluation of machine learning algorithms for the supervision of energy efficiency of district heating-supplied buildings

    International Nuclear Information System (INIS)

    Kiluk, Sebastian

    2017-01-01

    Highlights: • Energy efficiency classification sustainability benefits from knowledge prediction. • Diagnostic classification can be validated with its dynamics and current data. • Diagnostic classification dynamics provides novelty extraction for knowledge update. • Data mining comparison can be performed with knowledge dynamics and uncertainty. • Diagnostic information refinement benefits form comparing classifiers dynamics. - Abstract: Modern ways of exploring the diagnostic knowledge provided by data mining and machine learning raise some concern about the ways of evaluating the quality of output knowledge, usually represented by information systems. Especially in district heating, the stationarity of efficiency models, and thus the relevance of diagnostic classification system, cannot be ensured due to the impact of social, economic or technological changes, which are hard to identify or predict. Therefore, data mining and machine learning have become an attractive strategy for automatically and continuously absorbing such dynamics. This paper presents a new method of evaluation and comparison of diagnostic information systems gathered algorithmically in district heating efficiency supervision based on exploring the evolution of information system and analyzing its dynamic features. The process of data mining and knowledge discovery was applied to the data acquired from district heating substations’ energy meters to provide the automated discovery of diagnostic knowledge base necessary for the efficiency supervision of district heating-supplied buildings. The implemented algorithm consists of several steps of processing the billing data, including preparation, segmentation, aggregation and knowledge discovery stage, where classes of abstract models representing energy efficiency constitute an information system representing diagnostic knowledge about the energy efficiency of buildings favorably operating under similar climate conditions and

  1. Detailed feasibility study of a small-hydro power plant in Zerni on the municipal drinking water supply; Etude detaillee de faisabilite pour l'installation d'une petite centrale sur l'adduction d'eau potable de Zerni - Rapport final

    Energy Technology Data Exchange (ETDEWEB)

    Reul, B. [MHyLab, Montcherand (Switzerland); Perruchoud, A. [SierreEnergie SA, Sierre (Switzerland)

    2009-02-15

    This report for the Swiss Federal Office of Energy (SFOE) takes a look at a project for the realisation of a small hydro-power plant on the municipal drinking water supply of the city of Sierre, Switzerland. The installation is to be made at the site of a new reservoir in Zerni. The report presents details on the hydrological data and the dimensioning of the installation. The hydrological installations and the turbine foreseen are described and discussed, as are the applicable water regulations. The electricity production expected is discussed, as is the economic viability of the project.

  2. Solar heating for a village; Ein Dorf heizt solar

    Energy Technology Data Exchange (ETDEWEB)

    Roepcke, Ina

    2013-07-05

    In Buesingen (administrative district of Konstanz) a solar thermal system with 1091 sqm collector area is put into operation. Together with two wood chip boilers they supply more than 100 private and municipal buildings with regenerative heat. [German] In Buesingen im Landkreis Konstanz ist eine solarthermische Anlage mit 1091 qm Kollektorflaeche in Betrieb gegangen. Zusammen mit zwei Hackschnitzelkesseln versorgt sie ueber 100 private und kommunale Gebaeude mit regenerativer Waerme.

  3. Indicadores epidemiológicos aplicáveis a estudos sobre a associação entre saneamento e saúde de base municipal Epidemiological indicators applied to studies about association between water supply and sanitation and health based on data at municipal level

    Directory of Open Access Journals (Sweden)

    Silvano Silvério da Costa

    2005-06-01

    programs, as well as for identification of priorities, rational planning and funding of water supply and sanitation projects. The present paper is part of a broader study on the selection of sanitary indicators to be used as "sentinel indicators" for prevention and control of diseases associated to water and sanitation. In this context, this paper presents a brief literature review, descriptive statistics of some epidemiological indicators collected from municipalities of 4 Brazilian States, as well as a discussion on the applicability of these indicators in studies of this nature. Among the epidemiological indicators evaluated, infant mortality, diarrhoea mortality in children under 5 years old and the diarrhoea morbidity in children under 5 years old based on data from the Brazilian Monitoring of Acute Diarrhoeal Disease program seem to be the more adequate.

  4. Development of objectives for the business operations and real estate management of the municipalities. Kuntien liikelaitostoimintojen ja kiinteistoenhoidon tavoitteellinen kehittaeminen

    Energy Technology Data Exchange (ETDEWEB)

    Kalliomaeki, M [Suomen Kunnallisliitto, Helsinki (Finland)

    1987-01-01

    In 1986 a research project was started dealing with the development of district heating, water supply and sewerage operations and real estate management of the municipalities. It was carried out as a test operation project in three municipalities: Asikkala, Hollola and Laukaa. It aimed at bringing about resources for a continuous development of the operations. The project ended formally by planning objectives for the year 1988. The development work in the test municipalities goes on. An all-inclusive method of development was applied in the project with the objective to combine theory and practice. The purpose was to find practical means of improving the profitability of the municipalities' district heating operations and real estate management under the prevailing conditions. The form of organisation or the accounting systems were not as such objects for the research but it was found that these do affect the profitability of operations, i.a. through the clarity of motivation and clarity of questions to do with responsibility and authority. According to the research, the applied contents- and profit-oriented control of operations improves the preconditions profitable municipal district heating operations and real estate management. However, the present means of control (planning, accounting and follow-up systems) used in the municipal administrations support an input-oriented type of leadership. For this reason, those rules which control i.a. the staff administration, planning practices, profit follow-up practices, accounting systems and the utilisation and functions of data technology should be developed to support a profit-oriented type of control.

  5. Allegheny County Municipal Boundaries

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — This dataset demarcates the municipal boundaries in Allegheny County. Data was created to portray the boundaries of the 130 Municipalities in Allegheny County the...

  6. 77 FR 61595 - Northern Illinois Municipal Power; Notice of Filing

    Science.gov (United States)

    2012-10-10

    ... Illinois Municipal Power filed its Revised and Superseding Proposed Revenue Requirement for reactive supply... Reference Room in Washington, DC. There is an ``eSubscription'' link on the web site that enables...

  7. SPICE modelling of a coupled piezoelectric-bimetal heat engine for autonomous Wireless Sensor Nodes (WSN) power supply

    Energy Technology Data Exchange (ETDEWEB)

    Boughaleb, J; Monfray, S; Vine, G; Arnaud, A; Puscasu, O; Maitre, C; Trochut, S; Hasbani, F; Di Gilio, T; Heinrich, V; Urard, P; Grasset, J C; Boeuf, F; Skotnicki, T [STMicroelectronics, 850 rue Jean Monet – 38920 Crolles (France); Cottinet, P J; Guyomar, D [LGEF, INSA Lyon, 8 rue de la Physique – 69621 Villeurbanne Cedex (France); Boisseau, S; Duret, A B [CEA-LETI, 17 rue des Martyrs – 38054 Grenoble Cedex 9 (France); Quenard, S [CEA-LITEN, 17 rue des Martyrs – 38054 Grenoble Cedex 9 (France)

    2014-11-27

    This paper deals with an electrical modelling and optimization of a thermal energy harvester dedicated to power autonomous systems. Such devices based on bimetal strips and piezoceramics turn thermal gradients into electricity by a two-step conversion mechanism. This work focuses first on a demonstration of a ST-WSN (GreenNet demonstration platform) supplied by the harvester to validate, for the first time, the harvesters viability. That demonstration focuses attention on the need for an optimized power management circuit for piezoelectric generators able to reach output voltages up to 20 V. The work deals then with the proposal of an equivalent lumped element model of the piezoelectric transducer with its SPICE implementation to enable the optimization of a dedicated power management circuit based on the Pulsed Synchronous Charge Extractor (PSCE). Simulations using the SPICE model and the power management circuit lead to an increased extracted power by 144%.

  8. SPICE modelling of a coupled piezoelectric-bimetal heat engine for autonomous Wireless Sensor Nodes (WSN) power supply

    International Nuclear Information System (INIS)

    Boughaleb, J; Monfray, S; Vine, G; Arnaud, A; Puscasu, O; Maitre, C; Trochut, S; Hasbani, F; Di Gilio, T; Heinrich, V; Urard, P; Grasset, J C; Boeuf, F; Skotnicki, T; Cottinet, P J; Guyomar, D; Boisseau, S; Duret, A B; Quenard, S

    2014-01-01

    This paper deals with an electrical modelling and optimization of a thermal energy harvester dedicated to power autonomous systems. Such devices based on bimetal strips and piezoceramics turn thermal gradients into electricity by a two-step conversion mechanism. This work focuses first on a demonstration of a ST-WSN (GreenNet demonstration platform) supplied by the harvester to validate, for the first time, the harvesters viability. That demonstration focuses attention on the need for an optimized power management circuit for piezoelectric generators able to reach output voltages up to 20 V. The work deals then with the proposal of an equivalent lumped element model of the piezoelectric transducer with its SPICE implementation to enable the optimization of a dedicated power management circuit based on the Pulsed Synchronous Charge Extractor (PSCE). Simulations using the SPICE model and the power management circuit lead to an increased extracted power by 144%

  9. SPICE modelling of a coupled piezoelectric-bimetal heat engine for autonomous Wireless Sensor Nodes (WSN) power supply

    Science.gov (United States)

    Boughaleb, J.; Monfray, S.; Vine, G.; Cottinet, P. J.; Arnaud, A.; Boisseau, S.; Duret, A. B.; Quenard, S.; Puscasu, O.; Maitre, C.; Trochut, S.; Hasbani, F.; Di Gilio, T.; Heinrich, V.; Urard, P.; Grasset, J. C.; Boeuf, F.; Guyomar, D.; Skotnicki, T.

    2014-11-01

    This paper deals with an electrical modelling and optimization of a thermal energy harvester dedicated to power autonomous systems. Such devices based on bimetal strips and piezoceramics turn thermal gradients into electricity by a two-step conversion mechanism. This work focuses first on a demonstration of a ST-WSN (GreenNet demonstration platform) supplied by the harvester to validate, for the first time, the harvesters viability. That demonstration focuses attention on the need for an optimized power management circuit for piezoelectric generators able to reach output voltages up to 20 V. The work deals then with the proposal of an equivalent lumped element model of the piezoelectric transducer with its SPICE implementation to enable the optimization of a dedicated power management circuit based on the Pulsed Synchronous Charge Extractor (PSCE). Simulations using the SPICE model and the power management circuit lead to an increased extracted power by 144%.

  10. 130 kV 130 A High voltage switching mode power supply for neutral beam plasma heating: design issues

    International Nuclear Information System (INIS)

    Ganuza, D.; Del Rio, J.M.; Garcia, I.; Garcia, F.; Garcia de Madinabeitia, P.; Perez, A.; Zabaleta, J.R.

    2003-01-01

    The company JEMA has designed and manufactured two High Voltage Switching Mode Power Supplies (HVSMPS), rated at 130 kV dc and 130 A, each of which will feed the accelerator grids of two Positive Ion Neutral Injector (PINI) loads, to be installed at the Joint European Torus (EFDA-JET facility located at Culham, UK). The solution designed by JEMA includes two matching transformers which adapt the 36 kV of the JET AC power distribution network to the required 670 V at the secondary side. Additionally, such transformers provide a 30 deg.phase shift which is required by a 30000 A 12 pulse thyristor rectifier. The obtained and stabilised 650 V feed 120 IGBT invertors, which operate at 2778 Hz with modulated square waveform. Each invertor feeds a High Insulation High Frequency Transformer. The 120 transformers corresponding to one power supply are arranged in three oil filled tanks and provide the main insulation from the low voltage to the high voltage side. The square waveform obtained at the secondary of each transformer is rectified by means of a diode bridge. The connection in series of the 120 diode bridges provides the required 130 kV d.c. at the output. In order to protect the load, a redundant solid state crowbar has been designed. Such short circuiting device is composed of 26 Light Triggered Thyristors (LTTs), connected in series. Electrical simulations have been carried out in order to ensure that the system complies with the requirements of high accuracy and adequate protection of the load. The critical design of the High Voltage-High Frequency Transformers has also required electrostatic simulations of the electric field distribution

  11. A fluidized bed furnace fired with biomass waste to supply heat for a spray dryer in a plant producing floortiles

    Energy Technology Data Exchange (ETDEWEB)

    Gulyurtlu, I.; Andre, R.; Mendes, J.; Monteiro, A.; Cabrita, I. [Instituto Nacional de Engenharia e Tecnologia Industrial, Lisboa (Portugal)

    1993-12-31

    This project has been implemented at a factory producing floortiles for domestic use. The project consists of a fluidized bed combustion system burning coal or wood or a mixture of both to produce hot combustion gases to provide heat for spray drying process. The system was designed by INETI for a maximum output of 8 MW thermal energy and all the engineering calculations were carried out to dimension the furnace to provide this amount of heat. Shallow bed concept was used for complete burning of the biomass particles which contained volatiles up to 75% by weight. The sand bed was used as a flame stabilizer for the combustion of volatiles. The combustion of volatiles in the freeboard was mainly controlled by mixing ashes and other impurities. The combustion temperature had to be maintained in the range 700--800{degrees}C to achieve combustion efficiencies of 85% or more. The combustion efficiency (1) did not increase substantially above 90% of excess air although levels of up to 120% were used during combustion and (2) was found to increase through air staging in the order of 20 to 25%, by simply adding 45 to 55% of the air required to the freeboard zone. No SO{sub 2} was observed in flue gases when burning only biomass but there was some NO{sub x} formed and the level of conversion of fuel-N to NO{sub x} was found to be about 25--30%.

  12. Preliminary safety analysis of a PBMR supplying process heat to a co-located ethylene production plant

    International Nuclear Information System (INIS)

    Scarlat, Raluca O.; Cisneros, Anselmo T.; Koutchesfahani, Tawni; Hong, Rada; Peterson, Per F.

    2012-01-01

    This paper considers the safety analysis and licensing approach for co-locating a pebble bed modular reactor (PBMR) to provide process heat to an ethylene production unit. The PBMR is an advanced nuclear reactor design that provides 400 MW of thermal energy. Ethylene production is an energy intensive process that utilizes large gas furnaces to provide the heat for the process. Coupling a PBMR with an ethylene production plant would open a new market for nuclear power, and would provide the chemical industry with a cleaner power source, helping to achieve the Clean Air Act standards, and eliminating the 0.5 ton of CO 2 emissions per ton of produced ethylene. Our analysis uses the Chevron Phillips chemical plant in Sweeney, TX as a prototypical site. The plant has four ethylene production trains, with a total power consumption of 2.4 GW, for an ethylene output of 3.7 million tons per year, 4% of the global ethylene production capacity. This paper proposes replacement of the gas furnaces by low-emission PBMR modules, and presents the safety concerns and risk mitigation and management options for this coupled system. Two coupling design options are proposed, and the necessary changes to the design basis events and severe accidents for the PBMR licensing application are discussed. A joint effort between the chemical and the nuclear entities to optimize the coupling design, establish preventive maintenance procedures, and develop emergency response plans for both of the units is recommended.

  13. Preliminary safety analysis of a PBMR supplying process heat to a co-located ethylene production plant

    Energy Technology Data Exchange (ETDEWEB)

    Scarlat, Raluca O., E-mail: rscarlat@nuc.berkeley.edu [University of California Berkeley, Nuclear Engineering, 4118 Etcheverry Hall, Berkeley, CA 94720 (United States); Cisneros, Anselmo T. [University of California Berkeley, Nuclear Engineering, 4118 Etcheverry Hall, Berkeley, CA 94720 (United States); Koutchesfahani, Tawni [University of California, Chemical and Biomolecular Engineering, 201 Gilman Hall, Berkeley, CA 94720 (United States); Hong, Rada; Peterson, Per F. [University of California Berkeley, Nuclear Engineering, 4118 Etcheverry Hall, Berkeley, CA 94720 (United States)

    2012-10-15

    This paper considers the safety analysis and licensing approach for co-locating a pebble bed modular reactor (PBMR) to provide process heat to an ethylene production unit. The PBMR is an advanced nuclear reactor design that provides 400 MW of thermal energy. Ethylene production is an energy intensive process that utilizes large gas furnaces to provide the heat for the process. Coupling a PBMR with an ethylene production plant would open a new market for nuclear power, and would provide the chemical industry with a cleaner power source, helping to achieve the Clean Air Act standards, and eliminating the 0.5 ton of CO{sub 2} emissions per ton of produced ethylene. Our analysis uses the Chevron Phillips chemical plant in Sweeney, TX as a prototypical site. The plant has four ethylene production trains, with a total power consumption of 2.4 GW, for an ethylene output of 3.7 million tons per year, 4% of the global ethylene production capacity. This paper proposes replacement of the gas furnaces by low-emission PBMR modules, and presents the safety concerns and risk mitigation and management options for this coupled system. Two coupling design options are proposed, and the necessary changes to the design basis events and severe accidents for the PBMR licensing application are discussed. A joint effort between the chemical and the nuclear entities to optimize the coupling design, establish preventive maintenance procedures, and develop emergency response plans for both of the units is recommended.

  14. Adaptive municipal electronic forms

    NARCIS (Netherlands)

    Kuiper, Pieternel; van Dijk, Elisabeth M.A.G.; Bondarouk, Tatiana; Ruel, Hubertus Johannes Maria; Guiderdoni-Jourdain, Karine; Oiry, Ewan

    Adaptation of electronic forms (e-forms) seems to be a step forward to reduce the burden for people who fill in forms. Municipalities more and more offer e-forms online that can be used by citizens to request a municipal product or service or by municipal employees to place a request on behalf of a

  15. Heat plan Denmark 2010. Main report; Varmeplan Danmark 2010. Hovedrapport

    Energy Technology Data Exchange (ETDEWEB)

    Dyrelund, A.; Fafner, K.; Ulbjerg, F. (and others)

    2010-09-15

    Heat Plan Denmark 2010 is an update of Heat Plan Denmark 2008 and confirms how the sector has reduced the CO{sub 2} emission in Denmark since 1980 and how this development can continue in a cost effective way to an almost CO{sub 2} neutral heating sector in 2030. The study is based on an overall least cost evaluation of the best existing technology taking into account the interaction between buildings, district heating and the power system with a large share of wind energy. It provides recommendations to the central administration, to municipalities, to district heating companies and to consumers on how to continue the development of the heating sector in the most cost effective way towards a CO{sub 2} neutral society in a sustainable way, mainly: 1) to increase the market share of District heating from 50 % to 70%; 2) to supply 70% of all new buildings with district heating; 3) to supply 30 % with heat pumps; 4) to encourage end-users to save heat and reduce the return temperature; 5) to use more renewable energy, such as waste to energy with fluegas condensation, biofuel CHP, large scale solar heating, geothermal energy and electric boilers and heat pumps to absorb surplus wind energy. (ln)

  16. Conceptual design of pulsed high voltage and high precision power supply for a cyclotron auto-resonance maser (CARM) for plasma heating

    International Nuclear Information System (INIS)

    Zito, Pietro; Maffia, Giuseppe; Lampasi, Alessandro

    2015-01-01

    Highlights: • ENEA started a project to develop a cyclotron auto-resonance maser (CARM). • This facility requires an advanced pulsed high voltage power supply (HVPS). • The conceptual design answers to the performances requested for CARM HVPS. • The pulse transformer parameters were estimated according to IEEE standards. • PWM PID-based controller has been optimized to follow very fast rectangular pulses. - Abstract: Due to the high electron temperature during the plasma burning, both a higher power (>1 MW) and a higher frequency (up to 300 GHz) are required for plasma heating in future fusion experiments like DEMO. For this task, ENEA started a project to develop a cyclotron auto-resonance maser (CARM) able to produce an electron radiation in synchronism with the electromagnetic field and to transfer the electron beam kinetic energy to the plasma. This facility requires an advanced pulsed high voltage power supply (HVPS) with the following technical characteristics: variable output voltage up to 700 kV; variable pulse length in the range 5–50 μs; overshoot < 2%; rise time < 1 μs; voltage accuracy (including drop, ripple and stability) <0.1%. This paper describes the conceptual design and the technical solutions adopted to achieve the performance requested for the CARM HVPS.

  17. Investigation of the feasibility of the solar-/geothermally-assisted heat supply system Gesotherm S; Untersuchung der Durchfuehrbarkeit des solar-/ geothermisch gestuetzten Waermeversorgungssystems Gesotherm S

    Energy Technology Data Exchange (ETDEWEB)

    Liebisch, H. [EKT Energie und Kommunal-Technologie GmbH, Berlin (Germany)

    1998-12-31

    The project has been running since 1st March 1998 and is supposed to investigate the technical feasibility and economic efficiency of the Gesotherm S heat supply system in the residential area Berlin-Biesdorf/Habichtshorst (1,000 flats). Main points of investigation are: proof of feasibility and geothermal analysis of the deep pit; analysis of storage possibilities and technical synergies of combined solar-geothermal operation; determination of the regenerative supply ratio; calculation of economic efficiency; estimation of cost-saving potentials. The whole system is simulated for these studies. A new simulation model was developed for the pit. Simulations are based on the SMILE-simulation environment developed by the Technical University of Berlin. First estimates indicate costs of DM 200 per MWh without subsidies. (orig.) [Deutsch] Mit dem seit 1. Maerz 1998 laufenden Vorhaben soll die technische Realisierbarkeit und wirtschaftliche Attraktivitaet des Waermeversorgungssystems Gesotherm S am Beispiel der Nahwaermeversorgung eines Wohngebietes (ca. 1.000 WE) in Berlin-Biesdorf/Habichtshorst umfassend untersucht werden. Schwerpunkte der Untersuchung: - Machbarkeitsnachweis und geothermische Analyse der Tiefensonde - Analyse der Speichermoeglichkeiten und der technischen Synergieeffekte des solar-/geothermischen Kombinationsbetriebes - Ermittlung der regenerativen Deckungsrate - Berechnung der Wirtschaftlichkeit - Abschaetzung der Kostensenkungspotentiale. Fuer die Untersuchung wird das Gesamtsystem simuliert. Speziell fuer die Tiefensonde wird ein neues Simulationsmodell entwickelt. Basis ist die, an der TU-Berlin entwickelte, Simulationsumgebung SMILE. Erste Abschaetzungen ergaben Waermekosten ohne Subventionen von unter 200 DM/MWh. (orig.)

  18. Conceptual design of pulsed high voltage and high precision power supply for a cyclotron auto-resonance maser (CARM) for plasma heating

    Energy Technology Data Exchange (ETDEWEB)

    Zito, Pietro, E-mail: pietro.zito@enea.it; Maffia, Giuseppe; Lampasi, Alessandro

    2015-10-15

    Highlights: • ENEA started a project to develop a cyclotron auto-resonance maser (CARM). • This facility requires an advanced pulsed high voltage power supply (HVPS). • The conceptual design answers to the performances requested for CARM HVPS. • The pulse transformer parameters were estimated according to IEEE standards. • PWM PID-based controller has been optimized to follow very fast rectangular pulses. - Abstract: Due to the high electron temperature during the plasma burning, both a higher power (>1 MW) and a higher frequency (up to 300 GHz) are required for plasma heating in future fusion experiments like DEMO. For this task, ENEA started a project to develop a cyclotron auto-resonance maser (CARM) able to produce an electron radiation in synchronism with the electromagnetic field and to transfer the electron beam kinetic energy to the plasma. This facility requires an advanced pulsed high voltage power supply (HVPS) with the following technical characteristics: variable output voltage up to 700 kV; variable pulse length in the range 5–50 μs; overshoot < 2%; rise time < 1 μs; voltage accuracy (including drop, ripple and stability) <0.1%. This paper describes the conceptual design and the technical solutions adopted to achieve the performance requested for the CARM HVPS.

  19. Estimation of energetic efficiency of heat supply in front of the aircraft at supersonic accelerated flight. Part II. Mathematical model of the trajectory boost part and computational results

    Science.gov (United States)

    Latypov, A. F.

    2009-03-01

    The fuel economy was estimated at boost trajectory of aerospace plane during energy supply to the free stream. Initial and final velocities of the flight were given. A model of planning flight above cold air in infinite isobaric thermal wake was used. The comparison of fuel consumption was done at optimal trajectories. The calculations were done using a combined power plant consisting of ramjet and liquid-propellant engine. An exergy model was constructed in the first part of the paper for estimating the ramjet thrust and specific impulse. To estimate the aerodynamic drag of aircraft a quadratic dependence on aerodynamic lift is used. The energy for flow heating is obtained at the sacrifice of an equivalent decrease of exergy of combustion products. The dependencies are obtained for increasing the range coefficient of cruise flight at different Mach numbers. In the second part of the paper, a mathematical model is presented for the boost part of the flight trajectory of the flying vehicle and computational results for reducing the fuel expenses at the boost trajectory at a given value of the energy supplied in front of the aircraft.

  20. SECURE nuclear district heating plant

    International Nuclear Information System (INIS)

    Nilsson; Hannus, M.

    1978-01-01

    The role foreseen for the SECURE (Safe Environmentally Clean Urban REactor) nuclear district heating plant is to provide the baseload heating needs of primarily the larger and medium size urban centers that are outside the range of waste heat supply from conventional nuclear power stations. The rationale of the SECURE concept is that the simplicity in design and the inherent safety advantages due to the use of low temperatures and pressures should make such reactors economically feasible in much smaller unit sizes than nuclear power reactors and should make their urban location possible. It is felt that the present design should be safe enough to make urban underground location possible without restriction according to any criteria based on actual risk evaluation. From the environmental point of view, this is a municipal heat supply plant with negligible pollution. Waste heat is negligible, gaseous radioactivity release is negligible, and there is no liquid radwaste release. Economic comparisons show that the SECURE plant is competitive with current fossil-fueled alternatives. Expected future increase in energy raw material prices will lead to additional energy cost advantages to the SECURE plant

  1. Designing a Municipality

    DEFF Research Database (Denmark)

    Jungersen, Ulrik; Hansen, Poul H. Kyvsgård

    2014-01-01

    Can a municipality be designed? The municipality Kolding in the southern part of Denmark asked this question. The idea emerged as a response to a recognized need for new ways of branding and developing the municipality. It is an ongoing process that was kicked off in 2012 and this paper is theref......Can a municipality be designed? The municipality Kolding in the southern part of Denmark asked this question. The idea emerged as a response to a recognized need for new ways of branding and developing the municipality. It is an ongoing process that was kicked off in 2012 and this paper...... is therefore focusing primarily on the process of changing the perception of how to organize development in a municipality. The most important elements in transforming the whole development setup are described. Finally, a short case describing one of the significant results is included....

  2. IMPROVEMENT OF SYSTEMS OF TECHNICAL WATER SUPPLY WITH COOLING TOWERS FOR HEAT POWER PLANTS TECHNICAL AND ECONOMIC INDICATORS PERFECTION. Part 2

    Directory of Open Access Journals (Sweden)

    Yu. A. Zenovich-Leshkevich-Olpinskiy

    2016-01-01

    Full Text Available The method of calculation of economic efficiency that can be universal and is suitable for feasibility study of modernization of irrigation and water distribution system of cooling towers has been developed. The method takes into account the effect of lower pressure exhaust steam in the condenser by lowering the temperature of the cooling water outlet of a cooling tower that aims at improvement of technical and economic indicators of heat power plants. The practical results of the modernization of irrigation and water distribution system of a cooling tower are presented. As a result, the application of new irrigation and water distribution systems of cooling towers will make it possible to increase the cooling efficiency by more than 4 оС and, therefore, to obtain the fuel savings by improving the vacuum in the turbine condensers. In addition, the available capacity of CHP in the summer period is increased. The results of the work, the experience of modernization of irrigation and water distribution systems of the Gomel CHP-2 cooling towers system, as well as the and methods of calculating of its efficiency can be disseminated for upgrading similar facilities at the power plants of the Belarusian energy system. Some measures are prosed to improve recycling systems, cooling towers and their structures; such measures might significantly improve the reliability and efficiency of technical water supply systems of heat power plants.

  3. Planning and constructional instruments that support an energy-efficient supply of heat; Planungs- und Bauinstrumente zugunsten einer energieeffizienten Waermeversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Renaud, P.; Bonnet, C. [Planair SA, Bureau d' ingenieurs SIA, La Sagne (Switzerland); Hoesli, B.; Wuethrich, M. [Hesse und Schwarze und Partner, Buero fuer Raumplanung AG, Zuerich (Switzerland); Gerheuser, F. W. [Polis, Politikberatung und Sozialforschung, Brugg (Switzerland)

    2004-07-01

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) and the Cantons of Basel-Stadt, Berne, Geneva and Zurich presents the results of a study that examined how regulations in the planning and construction areas can be used to support the saving of energy, its efficient use and how the proportion of renewable sources of energy can be increased. Topics discussed include dense building, passive energy generation, obligatory refurbishing of existing building with high energy consumption, use of the 'Minergie' low energy-consumption standard for new and refurbished buildings, aid for energy refurbishment, co-ordination of the use of district heating, definition of intensive-farming areas, development of energy concepts with restrictions on energy consumption and carbon dioxide production as well as aids for negotiation and the development of target agreements. The report suggests an order of priority in which the measures should be considered and makes suggestions for action to be taken in various areas.

  4. Current and future prospects for heat recovery from waste in European district heating systems: A literature and data review

    International Nuclear Information System (INIS)

    Persson, Urban; Münster, Marie

    2016-01-01

    Municipal solid waste has seen increasing annual volumes for many decades in contemporary Europe and constitutes, if not properly managed, an environmental problem due to local pollution and greenhouse gas emissions. From an energy perspective, waste is also an alternative fuel for power and heat generation; energy recovery from waste represents an effective measure to reduce landfilling and avoid disposal emissions while simultaneously reducing the equivalent demand for primary energy supply. A key factor for obtaining the full synergetic benefits of this energy recovery is the presence of local heat distribution infrastructures, without which no large-scale recovery and utilisation of excess heat is possible. In this paper, which aims to estimate municipal solid waste volumes available for heat recovery in European district heating systems in 2030, a literature and data review is performed to establish and assess current and future EU (European Union) waste generation and management. Main conclusions are that more heat can be recovered from current Waste-to-Energy facilities operating at low average heat recovery efficiencies, that efficient incineration capacity is geographically concentrated, and that waste available for heat recovery in 2030 is equally determined by total generation volumes by this year as by future EU deployment levels of district heating. - Highlights: • European municipal solid waste time series data analysed from 1995 to 2012. • Review of modelling approaches to assess future European waste generation. • Weather corrected district heat data for EU Member States in 1995 and 2012. • Low average heat recovery efficiency in current European waste incineration. • Future heat recovery efficiencies as determinant as future generation volumes.

  5. Paths to bioenergy villages. A guideline for a independent supply of heat and electricity based on biomass in rural area. 3. ed.; Wege zum Bioenergiedorf. Leitfaden fuer eine eigenstaendige Waerme- und Stromversrogung auf Basis von Biomasse im laendlichen Raum

    Energy Technology Data Exchange (ETDEWEB)

    Ruppert, Hans; Eigner-Thiel, Swantje; Girschner, Walter; Karpenstein-Machan, Marianne; Roland, Folker; Ruwisch, Volker; Sauer, Benedikt; Schmuck, Peter

    2010-12-15

    Bioenergy villages are one component for the sustainable energy supply in rural areas. The guideline under consideration is intended to encourage people in villages to switch their heat supply and electricity supply on the bases of biomass. The focus of this process-oriented guideline is on: (1) A presentation of the social feasibility, especially the involvement, motivation and encouragement of the population; (2) The presentation of concepts for a nature-friendly cultivation of the required biomass; (3) The treatment of economic and legal issues from the perspective of the people involved.

  6. District heating versus local heating - Social supportability

    International Nuclear Information System (INIS)

    Matei, Magdalena; Enescu, Diana; Varjoghie, Elena; Radu, Florin; Matei, Lucian

    2004-01-01

    District heating, DH, is an energy source which can provide a cost-effective, environmentally friendly source of heat and power for cities, but only in the case of well running systems, with reasonable technological losses. The benefits of DH system are well known: environmental friendly, energy security, economic and social advantages. DH already covers 60% of heating and hot water needs in transition economies. Today, 70 % of Russian, Latvian and Belarus homes use DH, and heating accounts for one-third of total Russian energy consumption. Yet a large number of DH systems in the region face serious financial, marketing or technical problems because of the policy framework. How can DH issues be best addressed in national and local policy? What can governments do to create the right conditions for the sustainable development of DH while improving service quality? What policies can help capture the economic, environmental and energy security benefits of co-generation and DH? To address these questions, the International Energy Agency (IEA) hosted in 2002 and 2004 conference focusing on the crucial importance of well-designed DH policies, for exchanging information on policy approaches. The conclusions of the conference have shown that 'DH systems can do much to save energy and boost energy security, but stronger policy measures are needed to encourage wise management and investment. With a stronger policy framework, DH systems in formerly socialist countries could save the equivalent of 80 billion cubic meters of natural gas a year through supply side efficiency improvements. This is greater than total annual natural gas consumption in Italy'. More efficient systems will also decrease costs, reducing household bills and making DH competitive on long-term. This paper presents the issues: -Theoretical benefits of the district heating and cooling systems; - Municipal heating in Romania; - Technical and economic problems of DH systems and social supportability; - How

  7. Trends in municipal-well installations and aquifer utilization in southeastern Minnesota, 1880-1980

    Science.gov (United States)

    Woodward, D.G.

    1985-01-01

    Water distributed by municipal systems has been the largest off-stream use of water in southeastern Minnesota for the past 100 years. Water pumped by these systems in 1980 totaled 102.3 billion gallons, with 60.1 billion gallons supplied by ground water. Ground water supplies 294 of the 309 municipal systems in the area.

  8. Energy concepts for self-supplying communities based on local and renewable energy sources

    DEFF Research Database (Denmark)

    Petersen, Jens-Phillip

    2016-01-01

    The reduction of GHG emissions in buildings is a focus area of national energy policies, because buildings are responsible for a major share of energy consumption. Policies to increase the share of renewable energies and energy efficiency measures are implemented at local scale. Municipalities...... that virtually allow a heating energy and electricity supply fully based on local, renewable energy resources. The most feasible and cost-efficient variant is the use of local food production waste in a CHP plant feeding a district heating grid. The overall aim is to show that a self-sufficient heat......- and electricity supply of typical urban communities is possible and can be implemented in a cost-efficient way, if the energy planning is done systematically and in coherence with urban planning....

  9. Influence of different technologies on dynamic pricing in district heating systems: Comparative case studies

    DEFF Research Database (Denmark)

    Dominkovic, Dominik Franjo; Wahlroos, Mikko; Syri, Sanna

    2018-01-01

    District heating markets are often dominated by monopolies in both Denmark and Finland. The same companies, often owned by local municipalities, are usually operating both supplying plants and district heating networks, while the pricing mechanisms are rigid, often agreed upon for one year...... in advance. The mentioned ownership scheme may cause problems, when one tries to gain a third party access in order to deliver excess heat or heat from cheaper heating plants. In this paper, two case studies were carried out to simulate the district heating systems based on dynamic pricing. Case studies were...... carried out for Sønderborg, Denmark and Espoo, Finland. The results showed that dynamic pricing fosters feeding the waste heat into the grid, as dynamic pricing reduced the total primary energy consumption and CO2 emissions in both case studies. In the best scenarios, the weighted average heat price...

  10. Report on survey for environment harmonizing type energy community project for Chubu International Airport. District heat supply facilities using large-scale cogeneration systems; Chubu kokusai kuko kankyo chowagata energy community jigyo chosa hokokusho. Daikibo cogeneration chiiki netsu kyokyu shisetsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The Chubu International Airport is positioned as a hub airport scheduled to start its use in the early part of the 21st century, to which introduction of large-scale cogeneration systems was discussed. Structuring an energy supply system conscious of the 21st century is intended, that is friendly to the environment, is attached with importance on the economy, and has high reliability and safety. The systems have cogeneration capacity from 4,500 to 6,000 kW, and utilize high-pressure waste heat from the cogeneration system as the heat source. The system uses the high pressure waste heat, stored heat, and gas at the same time to achieve high economic performance brought about by heat storage and the best energy source mix, while attempting cascade utilization of the heat. Considerations were given to suppress the environmental and energy load on the district as low as possible for the coexistence with the district, and to build framework and coordination to return the merits to the district. Subsidy introduction also has a great effect to assure the economic performance. The optimal specific construction of the system was found in combining the utilization of energy generated from temperature difference in sea water as a heat source system, the topping system utilizing the high pressure waste heat available in the system, high-efficiency heat pumps, and the heat storing system utilizing electric power available at late night. (NEDO)

  11. Increased system benefit from cogeneration due to cooperation between district heating utility and industry

    Energy Technology Data Exchange (ETDEWEB)

    Danestig, M.; Henning, D. [Division of Energy Systems, Department of Mechanical Engineering, Linkoping Institute of Technology, Linkoping (Sweden)

    2004-07-01

    District heating and steam supply in the town Oernskoeldsvik in northern Sweden is in focus for this study. Low temperature waste heat from pulp manufacturing in the Donisjoe mill is now utilised for district heating production in heat pumps, which dominate district heating supply. Based on this traditional cooperation between the local district heating utility and the pulp industry, the parties discuss a partial outsourcing of the industrial steam supply to the utility, which may enable beneficial system solutions for both actors. The local utility must find a new location for a heating plant because a railway line is being built at the heat pump site. Planning for a new combined heat and power production (CHP) plant has started but its location is uncertain. If the plant can be situated close to the mill it can, besides district heating, produce steam, which can be supplied to adjacent industries. The municipality and its local utility are also considering investing in a waste incineration plant. But is waste incineration suitable for Ornskoeldsvik and how would it interact with cogeneration. Alternative cases have been evaluated with the MODEST energy system optimisation model, which minimises the cost for satisfying district heating and steam demand. The most profitable solution is to invest in a CHP plant and a waste incineration plant. Considering carbon dioxide emissions, the results from applying a local or a global perspective are remarkably different. In the latter case, generated electricity is assumed to replace power from coal condensing plants elsewhere in the North-European power grid. Therefore, minimum global CO{sub 2} emissions are achieved through maximal electricity production in a CHP plant. From this viewpoint, waste incineration should not be introduced because it would obstruct cogeneration. The study is carried out within the program Sustainable municipality run by the Swedish Energy Agency. (orig.)

  12. Fiscal 1976 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system; 1976 nendo taiyonetsu reidanbo kyuto system no kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-03-01

    This report describes the fiscal 1974-76 research result on solar cooling/heating and hot water supply systems. Research was made on survey and analysis of current R and D states, system analysis, energy impact analysis, installation sites of solar collectors, diffusion policy, profitability, and performance evaluation method. Main research results obtained are as follows. The effect of solar cooling/heating and hot water supply on the Japanese energy demand in 2000 is estimated to be 13% for residences and 5% for the other buildings. Environment pollution derived from solar cooling/heating is extremely less than that from conventional energy quantitatively. The facility cost is estimated to be probably 27,000yen/m{sup 2} in collector cost, and nearly 100,000yen/t in heat storage tank cost. As design data for solar cooling/heating systems, the estimation method of heat collection for every solar radiation rank, performance comparison of honeycomb type collectors, and various data for air heat collection systems are presented. (NEDO)

  13. Desempenho dos diferentes modelos institucionais de prestação dos serviços públicos de abastecimento de água: uma avaliação comparativa no conjunto dos municípios brasileiros Performance of different institutional management public models for water supply provision: a comparative analysis in Brazilian municipalities

    Directory of Open Access Journals (Sweden)

    Pedro Gasparini Barbosa Heller

    2012-09-01

    Full Text Available Este artigo desenvolve uma avaliação comparativa entre os modelos de prestação de serviços públicos de abastecimento de água vigentes no País. De forma bastante abrangente, o estudo compara os serviços de praticamente todos os municípios brasileiros, por meio da aplicação de métodos estatísticos de variância não paramétrica. Nessa avaliação, os serviços foram agrupados a partir da seguinte classificação: prestados sob a forma de administração direta; prestados sob a forma de administração indireta (autarquias municipais; empresas privadas; e modelos regionais. O ano base do estudo foi 2008, tendo sido empregados dados secundários obtidos a partir da Pesquisa Nacional de Saneamento Básico. Foi criado um conjunto de indicadores de desempenho, referente aos aspectos operacionais e gerenciais dos serviços. Os resultados indicam diferenças significativas entre os modelos avaliados.This paper presents a comparative assessment of the different institutional public models for water supply provision in Brazil. In an encompassing way, the study compares services of almost all Brazilian municipalities, by a nonparametric analysis of variance. For this assessment, services were grouped according to the following classification: managed by the municipality; managed by a municipal autarchy; private companies; and regional models. The base year of the study was 2008, and secondary data from the National Survey of Basic Sanitation were used. A set of performance indicators, related to operational and management aspects of services, was created. The results indicate significant differences between the evaluated models.

  14. Sustainability analysis. Development of various indicators of sustainability for technical environmental analysis and evaluation of local heat supply networks on the basis of regenerative energies in comparison to fossil energy sources

    International Nuclear Information System (INIS)

    Hehenberger-Risse, Diana

    2013-06-01

    The aim of this thesis is to define indicators to evaluate local heat supply systems based on renewable energy compared to fossil energy reference scenarios. With these indicators a assessment matrix was developed as a planning instrument for the realization of sustainable and energy-efficient local heat supply systems. Further inferences from single projects on regions can be done. In these thesis a method was developed to assess the sustainability of local heat supply systems with the focus on ecology under consideration of economically and social aspects. This method uses a set of indicators composed of Input-, Output-, Efficiency- and Balance indicators. To realize advancement in comparison to present situations, an environmental quality target to advance the environmental impacts of minimum 75% was defined. For the developing and application of the indicators different examples from projects and scenarios of combined heat production from Biomass, Biogas, Solar heat combined with near-surface geothermal storage; geothermal energy and fossil peakload supply were calculated. These scenarios were related to a basis fossil energy scenario. Overall, the two district heating projects Speichersdorf and Mitterteich were compared. In this case, the project Speichersdorf with different coverage areas and decrease heat densities was investigated. The lengths of electrical grid of two areas are 10,828 m and 6,027 m. Those were opposed to the biomass district-heating project Mitterteich with a grid length of 360 m and a higher heat density decrease. Furthermore, a scenario for heat supply was designed and calculated using geothermal plant operating in duplicate to provide heat to the large coverage area for the storage project village. The calculation of the various processes and scenarios was performed with the program GEMIS 4.8 based on the total heat generated (final energy) by the respective supply type. The study examined the main system components; boilers, solar heat

  15. Some Problems of the Integration of Heat Pump Technology into a System of Combined Heat and Electricity Production

    Directory of Open Access Journals (Sweden)

    G. Böszörményi

    2001-01-01

    Full Text Available The closure of a part of the municipal combined heat and power (CHP plant of Košice city would result in the loss of 200 MW thermal output within a realtively short period of time. The long term development plan for the Košice district heating system concentrates on solving this problem. Taking into account the extremely high (90 % dependence of Slovakia on imported energy sources and the desirability of reducing the emission of pollutantst the alternative of supplying of 100 MW thermal output from geothermal sources is attractive. However the indices of economic efficiency for this alternative are unsatisfactory. Cogeneration of electricity and heat in a CHP plant, the most efficient way of supplying heat to Košice at the present time. If as planned, geothermal heat is fed directly into the district heating network the efficiency would be greatly reduced. An excellent solution of this problem would be a new conception, preferring the utilization of geothermal heat in support of a combined electricity and heat production process. The efficiency of geothermal energy utilization could be increased through a special heat pump. This paper deals with several aspects of the design of a heat pump to be integrated into the system of the CHP plant.

  16. Heat pumps: heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Pielke, R

    1976-01-01

    The author firstly explains in a general manner the functioning of the heat pump. Following a brief look at the future heat demand and the possibilities of covering it, the various methods of obtaining energy (making use of solar energy, ground heat, and others) and the practical applications (office heating, swimming pool heating etc.) are explained. The author still sees considerable difficulties in using the heat pump at present on a large scale. Firstly there is not enough maintenance personnel available, secondly the electricity supply undertakings cannot provide the necessary electricity on a wide basis without considerable investments. Other possibilities to save energy or to use waste energy are at present easier and more economical to realize. Recuperative and regenerative systems are described.

  17. Waste Sites - Municipal Waste Operations

    Data.gov (United States)

    NSGIC Education | GIS Inventory — A Municipal Waste Operation is a DEP primary facility type related to the Waste Management Municipal Waste Program. The sub-facility types related to Municipal Waste...

  18. Esco in Danish municipalities

    DEFF Research Database (Denmark)

    Jensen, Jesper Ole; Hansen, Jesper Rohr; Nielsen, Susanne Balslev

    2012-01-01

    Purpose: The aim of this paper is to discuss the possible benefits of involving Energy Service Companies (ESCO) in realising energy savings in municipalities, and how ESCO projects can be formulated very differently in the various municipalities, according to building volume, use of technologies......, energy savings, type of collaboration etc. Background: Since 2008, several Danish municipalities have started energy retrofitting of municipal buildings, based on contracts with Energy Service Companies. In spite of the strong growth of ESCOs, there is also widespread scepticism about ESCO, as many...... approaches are being used in Danish municipalities, which we label the basic, the integrated and the strategic ESCO approaches. The three approaches include different ambitions, technologies, economies and innovation potentials. Whereas the basic approach implies a ‘traditional’ guarantee-based model...

  19. Indicators System Creation For The Energy Efficiency Benchmarking Of Municipal Power System Facilities

    Directory of Open Access Journals (Sweden)

    Davydenko L.V.

    2015-04-01

    Full Text Available The issues of the dataware of the comparative analysis procedure (benchmarking for municipal power system facilities energy efficiency level estimation with a view of the hierarchical structure of the heat supply system are considered. The aim of the paper is the system of indicators formation for characterizing the efficiency of energy usage as on objects on lowest so on highest levels of power systems, proceeding from features of their functioning. Benchmarking methodology allows carrying out the estimation of energy efficiency level on the base of a plurality of parameters without their generalization in one indicator, but requires ensuring their comparability. Using the methodology of available statistical information that did not require deep specification and additional inspection structuring objectives and tasks of energy efficiency estimation problem has been proposed for ensuring the opportunity of benchmarking procedure implementation. This makes it possible to form the subset of indicators that ensure enough specification of the object of study, taking into account the degree of abstraction for every hierarchical level or sub problem. For a comparative analysis of energy using efficiency in municipal power systems at the highest levels of the hierarchy a plurality of indicators of the energy efficiency has been formed. Indicators have been determined with consideration of the structural elements of heat supply systems, but allowing taking into account the efficiency of the initial state of the objects, their functioning, and the questions of energy resources accounting organization. Usage of the proposed indicators provides implementation of energy using efficiency monitoring in the municipal power system and allows getting complete overview of the problem.

  20. Steam supply for the Principality of Liechtenstein. Process heat for industrial applications; Dampflieferung fuer das Fuerstentum Liechtenstein. Prozesswaerme fuer die Industrie

    Energy Technology Data Exchange (ETDEWEB)

    Dokter, Ernst [VfA Buchs fuer Kraft-Waerme-Kopplung und das Ferndampfsystem, Buchs (Switzerland)

    2009-07-15

    Switzerland is leading the world in thermal waste management. There are 29 incinerators (KVA - Kehrichtverbrennungsanlagen) with a capacity of 3.7 million t.p.a. They are operated by industrial or municipal owners and by the Verein fuer Abfallentsorgung Buchs SG. (orig.)

  1. Fiscal 1999 basic research on promotion of joint implementation. Comprehensive feasibility study on efficiency improvement project for heat generation facilities and heat supply networks for district heating at districts in Moscow region, the Russian Federation (2 model districts within the region)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    For the purpose of conserving energy and reducing greenhouse gas, a survey is conducted for district heating facilities of the Khimki district and Voskresensk district in Moscow and for their heat supply networks. Four boilers existing at the Khimki district are all to be replaced by natural gas turbine centralized cogeneration plants, and four boilers existing at the Voskresensk district are all to be replaced by natural gas turbine cogeneration facilities. These projects are designated as Case 1 and Case 2, different from each other in terms of power generation capability and heat supply scale. As for investment, a total of 267-million dollars will be necessary for Case 1, and 208-million dollars for Case 2. As for energy conservation, energy will be saved by approximately 2.8-million tons in total in terms of oil in Case 1, and approximately 2-million tons in terms of oil in Case 2. As for greenhouse gas reduction, there will be a reduction of approximately 6.8-million tons in terms of CO2 in Case 1, and a reduction of approximately 4.9-million tons in terms of CO2 in Case 2. (NEDO)

  2. The Design of Hot Water Supply System of Solar Energy and Air Source Heat Pump%太阳能+空气源热泵的热水供应系统设计

    Institute of Scientific and Technical Information of China (English)

    卢春萍

    2015-01-01

    太阳能集中热水系统受到天气的影响难以全天候运行,需要设置辅助加热装置。以广州市宾馆热水供应为例,对太阳能空气源热泵的热水系统进行设计,包括空气源热泵热水机组选型计算、太阳能集热管面积计算、储热水箱的确定、集热循环水泵的确定。%Influenced by weather condition,it is difficult to run for hot water supply system of solar en-ergy all the time,and the auxiliary heating device need setting.Taking hot water supply in a hotel of Guangzhou city as an example in this paper,the heat pump system of solar energy and air source was designed,including the calculation of equipment selection of the air source heat pump, the calculation of the collector area,the determination of the heat storage tank,and the determina-tion of the circulating pump of the heat collection.

  3. Basic investigation on promotion of joint implementation in fiscal 2000. Investigations on modification and improvement project for Potoshani district heating and heat supplying facilities in Romania; 2000 nendo kyodo jisshi nado suishin kiso chosa hokokusho. Romania koku Potoshani chiiki danbo netsukyokyu setsubi no kaishu oyobi kaizen keikaku chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Discussions have been given on the improvement and modification project intended of saving energies and reducing greenhouse gas emission in the Potoshani district heating and heat supplying facilities in Romania. Thirty years have elapsed since the building of the Potoshani district heating and heat supplying facilities, whereas noticeable energy loss has occurred due to aged deterioration, such as thermal efficiency decrease, performance decrease, and hot water leakage due to piping corrosion. The present project is intended to improve the heat production and power generation facility efficiencies, and reduce the heat loss in heat transportation and distribution to less than 5%. The improvements will be implemented by replacing and rehabilitating the existing boilers, replacing the turbine generators, and replacing the transportation and distribution pipelines and heat exchangers. As a result of the discussions, the present project is estimated to result in annual fuel conservation of 35,820 tons of crude oil equivalent, and annual reduction of the greenhouse gas emission of 110,835 t-CO2. The total amount of the initial investment for the project would be 11.369 billion yen, and the payback period would be 12 years. The project will produce profit of 31.358 billion yen in 20 years, thus the project is financially feasible. (NEDO)

  4. LEAP: local environmental action plan. Municipality of Sopishte

    International Nuclear Information System (INIS)

    2004-01-01

    The establishment of the Municipality of Sopishte was preceded by the development of a kind of suburban settlement of Skopje, basically composed of illegally constructed individual houses for living. As a result from economic activities in the Municipality and the impacts from human factor, there are problems related to the disturbance of the quality of the basic environmental quality factors (water, air and soil), as well as threat to biological diversity and natural values and rarities. The Municipality of Sopishte is situated in hilly-mountain area. Significant sources of air pollution have not been recorded (in terms of industrial facilities) caused by the household neglectible air pollution caused by traffic. The Municipality is very poor in water resources. Almost 90% of the Municipality's territory are without river or stream. A potential source of water supply in this area is the river of Patishka, which is currently not used for water supply purposes. The solid waste, generated basically by the households, is not properly disposed (most frequently dumped on illegal dumping sites on the territory of the Municipality) and represents a serious problem making impacts on the quality of the environment. On the basis of the evaluation of identified environmental problems, priority activities required to be undertaken in short and medium term have been set up. Financial constrains have been taken into account in this regard. The proposed Action Plan reflects the observed needs of the population of the Municipality of Sopishte and the perception of the key problems

  5. Heat exchanger

    Science.gov (United States)

    Wolowodiuk, Walter

    1976-01-06

    A heat exchanger of the straight tube type in which different rates of thermal expansion between the straight tubes and the supply pipes furnishing fluid to those tubes do not result in tube failures. The supply pipes each contain a section which is of helical configuration.

  6. Heat exchanger

    International Nuclear Information System (INIS)

    Wolowodiuk, W.

    1976-01-01

    A heat exchanger of the straight tube type is described in which different rates of thermal expansion between the straight tubes and the supply pipes furnishing fluid to those tubes do not result in tube failures. The supply pipes each contain a section which is of helical configuration

  7. Esco in Danish municipalities

    DEFF Research Database (Denmark)

    Jensen, Jesper Ole; Hansen, Jesper Rohr; Nielsen, Susanne Balslev

    2011-01-01

    Purpose: The aim of this paper is to discuss the possible benefits of involving Energy Service Companies (ESCO) in realising energy savings in municipalities, and how ESCO projects can be formulated very differently in the various municipalities, according to building volume, use of technologies...... municipalities see an in-house approach as a better alternative. Approach (Theory/Methodology): Our research is based on literature studies and on qualitative interviews with Danish municipalities carrying out ESCO projects, as well as with ESCO providers. Results: Our studies suggest that different ESCO......, with relatively few buildings, energy retrofitting and low investments, the integrative and strategic approach include a higher degree of partnership, a more ambitious building renovation approach, and more innovative understandings of facilities management. We also compare ESCO with energy retrofitting as an in...

  8. Municipal Building Energy Usage

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — This data set contains energy use data from 2009-2014 for 139 municipally operated buildings. Metrics include: Site & Source EUI, annual electricity, natural...

  9. Application of elements of systems for solar heating and hot water supply in medical planning modules and submodules; Prilagane na elementi na sistemi za slynchevo otoplenie i dostavyane na topla voda v meditsinski planirovychni moduli i podmoduli

    Energy Technology Data Exchange (ETDEWEB)

    Aleksandrova, L. [Civil Engineering Higher School, Sofia (Bulgaria)

    2011-07-01

    Here is reviewed the application of some characteristic elements of well-known innovative solutions of systems for solar heating and hot water supply in buildings - in medical modules and submodules in extreme situations - natural disaster, industrial average or military conflict. Also are given exemplary schemes of situation of the characteristic elements of the planning schemes of selected modules in accordance with the dimensions of the refrigeration chambers. (author)

  10. Submission of the Federation of Canadian Municipalities to the House of Commons Standing Committee on Environment, Parliament of Canada in respect of the Standing Committee's study on global warming

    International Nuclear Information System (INIS)

    Brown, G.; Gilbert, R.; Goulet, D.

    1990-01-01

    The views of an organization representing Canadian municipalities concerning the effects of global warming and climatic change are presented. Overall concerns include the lack of ready availability of information on future climatic changes and the apparent weak leadership of the federal government with regard to environmental matters. Specific concerns on the direct effects of global warming on municipalities include the effects of flooding and drought on public services, a possible deterioration in water supply and quality, increasing risk of fires, immigration from drought-affected areas of the world, diseases relating to the spread of subtropical plants and animals, and changes in regulations concerning the use of energy and the design of buildings. From the municipal perspective, contributions to the prevention of climatic change would have to come from reducing energy use for transportation, such as encouraging greater use of public transit, and reducing energy use in buildings through improved design and installation of district heating/cooling systems

  11. Modeling the Mixing of Components in a Rotary Kiln While Burning Municipal Waste to Ensure Rational Use of Energy

    Directory of Open Access Journals (Sweden)

    Krot O.P.

    2017-08-01

    Full Text Available In Ukraine municipal waste is collected and delivered to a landfill. Municipal waste can be used as fuel to generate additional heat and electricity. The primary advantages of incineration are that waste volumes are reduced by an estimated, and the need for land and landfill space is greatly reduced. The plant has been designed by North–East Scientific Center using a thermocatalytic waste gas purification system with highly efficient dioxins reduction and heat energy recovery system. The technology of waste neutralization includes: a rotary kiln, an afterburner chamber, a new catalytic technologies for the treatment, a heat exchanger for heating combustion air, supply of alkali solution into the gas-escape channel, a carbon fiber adsorption filter. The organization of the right process of waste mixing in the rotary kiln allows increasing the efficiency of combustion, to equalize the combustion temperatures of the components of the waste and the completeness of the burning out of hazardous substances, which reduces the risk of their getting into the ash. The goal of the research is to build an analytical mathematical model of mixing of components in a rotary kiln. The model is based on the mathematical apparatus of Markov chains. The model allows to determine the concentration of the key component in any elementary volume of material circulating in the rotary kiln at any time and to calculate the statistical characteristics of the homogeneity of the mixture. The model will be used to research new designs of the equipment with rotary kilns.

  12. Reuse of waste water: impact on water supply planning

    Energy Technology Data Exchange (ETDEWEB)

    Mangan, G.F. Jr.

    1978-06-01

    As the urban population of the world increases and demands on easily developable water supplies are exceeded, cities have recourse to a range of management alternatives to balance municipal water supply and demand. These alternatives range from doing nothing to modifying either the supply or the demand variable in the supply-demand relationship. The reuse or recycling of urban waste water in many circumstances may be an economically attractive and effective management strategy for extending existing supplies of developed water, for providing additional water where no developable supplies exist and for meeting water quality effluent discharge standards. The relationship among municipal, industrial and agricultural water use and the treatment links which may be required to modify the quality of a municipal waste effluent for either recycling or reuse purposes is described. A procedure is described for analyzing water reuse alternatives within a framework of regional water supply and waste water disposal planning and management.

  13. The energy-effective redesign of district heat supply for the city of Eisenach; Energiewirtschaftliche Neugestaltung der Fernwaermeversorgung fuer die Stadt Eisenach

    Energy Technology Data Exchange (ETDEWEB)

    Stich, J. [Eproplan GmbH, Stuttgart (Germany)

    1996-09-01

    The present contribution describes the optimal heat generation for the district heat area ``North`` of the city of Eisenach and economic redesign of this district heat network. The district heat network is operated by the public utility of Eisenach (Eisenacher Versorgungs-Betriebe GmbH (EVB)), which also runs the heating station, that used to be fuelled with coal. (orig./GL) [Deutsch] Der vorliegende Beitrag befasst sich mit der optimalen Waermeerzeugung fuer das Fernwaerme-Versorgungsgebiet `Nord` der Stadt Eisenach und mit der wirtschaftlichen Umgestaltung dieses Fernwaermenetzes. Das Fernwaermenetz wird durch die Eisenacher Versorgungs-Betriebe GmbH (EVB) betrieben, wie auch das ehemalige kohlegefeuerte Heizwerk. (orig./GL)

  14. The bioenergy village. Prerequisites and consequences of an independent heat supply and power supply by biomass for the agriculture, ecology and lifestyle culture in the rural area; Das Bioenergiedorf. Voraussetzungen und Folgen einer eigenstaendigen Waerme- und Stromversorgung durch Biomasse fuer Landwirtschaft, Oekologie und Lebenskultur im laendlichen Raum

    Energy Technology Data Exchange (ETDEWEB)

    Ruppert, Hans [Goettingen Univ. (Germany). Geowissenschaftliches Zentrum; Goettingen Univ. (Germany). Interdisziplinaeres Zentrum fuer Nachhaltige Entwicklung; Schmuck, Peter (eds.) [Goettingen Univ. (Germany). Interdisziplinaeres Zentrum fuer Nachhaltige Entwicklung; UMC Potsdam (Germany). Inst. fuer Nachhaltigkeit und Umweltpolitik

    2010-07-01

    The transformation of the power supply and heat supply in the bioenergy village Juende (Federal Republic of Germany) on the basis of the energy source biomass was completed in the autumn 2005. Within this flagship project it could be shown that new ways are passable if the persons concerned design the new concepts. The contribution under consideration reports on the results of the final phase of this project describing the socio-economic and ecologic impacts of the implementation of the energy supply on the biomass in Juende. Within this part of project the disciplines crop science, soil science, geosciences, economy, psychology and sociology interact. The most important results of the single disciplines are presented in this final report.

  15. Representative of the municipality

    International Nuclear Information System (INIS)

    Castellnou Barcelo, J.

    2007-01-01

    Full text of publication follows. The decommissioning of the Vandellos-I nuclear power plant was a big challenge for the host community of Vandellos i l'Hospitalet de l'Infant and the close-by region. Closing down of the facility resulted in a rise of unemployment and a decrease of municipal income. The public was concerned with three issues: safety, transparency and information about the decommissioning, and economic future. Therefore, from the very beginning, municipal governments entered into negotiations with ENRESA on socio-economic benefits, including local employment in dismantling activities, and other types of financial and non-financial compensation. The ADE business association, i.e. a network of business organisations was created that guided the allotment of work to local firms. To satisfy public demand, local municipalities focused on the triad of safety, dialogue and local development, considered the three 'pillars of trust'. A Municipal Monitoring Commission was created, made up of representatives of affected municipalities, the regional government, the ADE business association, trade unions, the local university, the NPP management and ENRESA to monitor the dismantling process and regularly inform the local public. Items that were handled by this Commission included: - Work process monitoring. - Workers. - Materials Control. - Conventional and radioactive or contaminated waste management. - Emanation waste management (liquid and gas) - Safety (training and accidents). - Surveillance (radiological and environmental: dust, noise). - Effects. - Fulfillment of agreed conditions. A number of communication tools and channels were used, e.g., public information meetings, an information centre, the municipal magazine, the municipal radio station, and meetings with representatives of the local press. Particularly innovative was the idea to ask academics from the University of Tarragona to help with 'translating' technical information into language that could

  16. Price control in contracts of heat supply. May no more index be used in automatic price escalator clauses?; Preiskontrolle in Waermeliefervertraegen.. Darf in automatischen Preisgleitklauseln kein Index mehr genutzt werden?

    Energy Technology Data Exchange (ETDEWEB)

    Legler, Dirk [Guenther Heidel Wollenteit Hack Goldmann, Hamburg (Germany)

    2010-03-15

    Automatic price escalator clauses using a price index are AGB legally permissible in heat supply contracts. The fact that such price indices necessarily compound and orient themselves only at its own development of delivery costs is so long innocuous since the selection of these indices essentially can be justified on the basis of objective criteria. However, if the heat supplier as a user of the AGB uses no indices, but passes its costs of acquisition in its price escalator clause simply to 100 %, this evenly can be inadmissible according to paragraph 24 sect. 3, sentence 1 of AVB district heating regulation. This is valid if such a 'servile' passing signifies a neglect of conditions on the market.

  17. Types, risks and market of municipal bonds

    Directory of Open Access Journals (Sweden)

    Grujić Miloš

    2012-01-01

    Full Text Available Municipal bonds are issued by cities, municipalities or other local communities in order to quickly raise funds to cover current budget deficits, finish infrastructure projects for production and distribution of thermal energy, improve water supply, road construction, sports and recreation centers, schools or to fund such projects on more favorable terms than to borrow from banks. In this manner, necessary conditions are created for faster development of the real sector. The aim of this study is to evaluate the importance, possibilities and effects of the bond issue in the Republika Srpska aimed at securing funding for and development of local communities. Good examples that local government bonds enhance community development include capital markets in countries that have made the transition from the socialist system design, similar to the market of the Republika Srpska, like the Polish, Slovakian, Hungarian and Croatian markets. Issues of municipal bonds in the Republika Srpska succeeded mostly due to the workings of Investment-Development Bank of RS. However, it certainly shows that further high-quality municipal bonds could attract more interest from various institutional investors, especially mutual funds and insurance companies, and investors who are more risk-averse will be able to familiarize and inform themselves with the functioning of capital markets. In this manner, our capital market would confirm its essential role and thus become a generator of overall economic development of the Republika Srpska because it would enable more efficient collection and allocation of capital resources.

  18. Some aspects of radioprotection assurance in radiodiagnostic service activity from Chisinau municipality in 2006-2007

    International Nuclear Information System (INIS)

    Rosca, A.; Stanchevici, V.; Balanel, V.; Danga, V.

    2007-01-01

    Together with the accordance of specialized medical assistance, the population of Chisinau municipality needs the accordance of general radiodiagnostic and interventional qualitative assistance. The permanent multi-institutional supervision offers partial optimization of radioprotection in the Republic Medical and Sanitary Institutions (PMSI) of Chisinau municipality. The qualitative optimization of radioprotection in PMSI of Chisinau municipality can be assured while being supplied with the operation radio diagnostic equipment. (authors)

  19. Energy, economy and exergy evaluations of the solutions for supplying domestic hot water from low-temperature district heating in Denmark

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    . Evaluation models were built to investigate the energy, economy and exergy performances of the proposed domestic hot water systems in various configurations. The configurations of the devised domestic hot water substations were optimised to fit well with both low and ultra-low-temperature district heating...... °C and 50 °C district heating scenarios, while the individual micro tank solution consumed less energy and cost less in the 35 °C district heating scenario....

  20. ESCO in Danish municipalities

    DEFF Research Database (Denmark)

    Jensen, Jesper Ole; Hansen, Jesper Rohr; Nielsen, Susanne Balslev

    2013-01-01

    development with international ESCO experience as well as refer to public innovation literature. Combined with empirical case studies on ESCO contracting, we discuss factors and conditions that influence decisions on ESCO, the flexibility of ESCO contracts and whether it implies an innovative process...... mainly been used in the industry so far, but in recent years more and more municipalities have taken up ESCO initiatives, in order to retrofit existing public buildings, and to make them more energy efficient. ESCO is in many ways a new way of collaboration for Danish municipalities, and therefore...... in municipalities ESCOs have received much attention in different Danish energy-.efficiency policies, where ESCOs are often described as a promising way to achieve energy savings in existing housing and to overcome barriers encountered by other attempts at energy savings. Instead of assessing ESCO only...

  1. Municipal energy managers

    International Nuclear Information System (INIS)

    2004-01-01

    On 1 and 2 July, municipal energy managers from all over Europe met in Stuttgart, Germany. On these two days, more the 150 participants form 22 countries listened to presentations, took part in excursions to cutting-edge energy conservation projects in Stuttgart and, above all, participated in a broad array of workshops presented by experts firmly grounded in local practice. 27 experts drawn from 11 European countries showcased their projects and imparted their experience. The event has been accompanied by an exhibition of companies and service providers offering energy-conservation products and planning services. The first workshop dealt with energy management in Europe and examples from different active municipalities; the second one with energy management in Germany and best practice in the leading cities; the third one with non-municipal and European projects. (A.L.B.)

  2. Energy recovery from waste incineration: Assessing the importance of district heating networks

    International Nuclear Information System (INIS)

    Fruergaard, T.; Christensen, T.H.; Astrup, T.

    2010-01-01

    Municipal solid waste incineration contributes with 20% of the heat supplied to the more than 400 district heating networks in Denmark. In evaluation of the environmental consequences of this heat production, the typical approach has been to assume that other (fossil) fuels could be saved on a 1:1 basis (e.g. 1 GJ of waste heat delivered substitutes for 1 GJ of coal-based heat). This paper investigates consequences of waste-based heat substitution in two specific Danish district heating networks and the energy-associated interactions between the plants connected to these networks. Despite almost equal electricity and heat efficiencies at the waste incinerators connected to the two district heating networks, the energy and CO 2 accounts showed significantly different results: waste incineration in one network caused a CO 2 saving of 48 kg CO 2 /GJ energy input while in the other network a load of 43 kg CO 2 /GJ. This was caused mainly by differences in operation mode and fuel types of the other heat producing plants attached to the networks. The paper clearly indicates that simple evaluations of waste-to-energy efficiencies at the incinerator are insufficient for assessing the consequences of heat substitution in district heating network systems. The paper also shows that using national averages for heat substitution will not provide a correct answer: local conditions need to be addressed thoroughly otherwise we may fail to assess correctly the heat recovery from waste incineration.

  3. Drinking water quality of Sukkur municipal corporation

    International Nuclear Information System (INIS)

    Kandhar, I.A.; Ansari, A.K.

    2002-01-01

    SMC (Sukkur Municipal Corporation) supply the (filtered/settled) water for domestic purpose to the consumers, through intermittent water supply, from Phases I to IV. The water supply distribution network is underground and at most places pass parallel to sewerage lines. The grab sampling technique was followed for collecting representative samples. The official US-EPA and standard methods of water analysis have been used for drinking water quality analysis. DR/2000 spectrophotometer has been used for monitoring: Nitrates, Fluorides, Sulfates, Copper, Chromium, Iron and manganese. The trace metals Cr/sup 6/, Fe/sup 2+/ and other contaminants like; Turbidity and TSS (Total Suspended Solids) have been found higher than World Health Organization (WHO-1993) guideline values. (author)

  4. Heat Roadmap Europe

    DEFF Research Database (Denmark)

    David, Andrei; Mathiesen, Brian Vad; Averfalk, Helge

    2017-01-01

    The Heat Roadmap Europe (HRE) studies estimated a potential increase of the district heating (DH) share to 50% of the entire heat demand by 2050, with approximately 25–30% of it being supplied using large-scale electric heat pumps. This study builds on this potential and aims to document that suc......The Heat Roadmap Europe (HRE) studies estimated a potential increase of the district heating (DH) share to 50% of the entire heat demand by 2050, with approximately 25–30% of it being supplied using large-scale electric heat pumps. This study builds on this potential and aims to document...

  5. 76 FR 55449 - Self-Regulatory Organizations; Municipal Securities Rulemaking Board; Notice of Filing of...

    Science.gov (United States)

    2011-09-07

    ... purchasing of supplies. SIFMA noted that it understood why the wording of the gift prohibition for municipal... the Municipal Securities Rulemaking Board Consisting of Amendments to MSRB Rule G-20 (Gifts and... Commission a proposed rule change consisting of proposed amendments to MSRB Rule G-20 (on gifts and...

  6. Heat Roadmap Europe

    DEFF Research Database (Denmark)

    Hansen, Kenneth; Connolly, David; Lund, Henrik

    2015-01-01

    The cost of heat savings in buildings increase as more heat savings are achieved due to the state of the building stock and hence, alternatives other than savings typically become more economically feasible at a certain level of heat reductions. It is important to identify when the cost of heat...... savings become more expensive than the cost of sustainable heat supply, so society does not overinvest in heat saving measures. This study first investigates the heat saving potentials for different countries in Europe, along with their associated costs, followed by a comparison with alternative ways...... of supplying sustainable heating. Different heat production options are included in terms of individual and community heating systems. Furthermore, the levelised cost of supplying sustainable heat is estimated for both a single technology and from an energy system perspective. The results are analysed...

  7. Establishing an environmental profile of water supply in South Africa

    CSIR Research Space (South Africa)

    Brent, AC

    2006-11-01

    Full Text Available -losses in the supply system must receive attention, especially in the municipal-controlled part. Water quality impacts are also important, although through supporting processes, and specifically electricity generation. The boosting requirements attribute most...

  8. 77 FR 47061 - Northern Illinois Municipal Power Agency; Notice of Filing

    Science.gov (United States)

    2012-08-07

    ... Municipal Power Agency filed a Proposed Revenue Requirement for reactive supply service under Midwest... Reference Room in Washington, DC. There is an ``eSubscription'' link on the web site that enables...

  9. 77 FR 47060 - Missouri Joint Municipal Electric Utility Commission; Notice of Filing

    Science.gov (United States)

    2012-08-07

    ... Municipal Electric Utility Commission filed a Proposed Revenue Requirement for reactive supply service under... Room in Washington, DC. There is an ``eSubscription'' link on the web site that enables subscribers to...

  10. Research challenges in municipal solid waste logistics management.

    Science.gov (United States)

    Bing, Xiaoyun; Bloemhof, Jacqueline M; Ramos, Tania Rodrigues Pereira; Barbosa-Povoa, Ana Paula; Wong, Chee Yew; van der Vorst, Jack G A J

    2016-02-01

    During the last two decades, EU legislation has put increasing pressure on member countries to achieve specified recycling targets for municipal household waste. These targets can be obtained in various ways choosing collection methods, separation methods, decentral or central logistic systems, etc. This paper compares municipal solid waste (MSW) management practices in various EU countries to identify the characteristics and key issues from a waste management and reverse logistics point of view. Further, we investigate literature on modelling municipal solid waste logistics in general. Comparing issues addressed in literature with the identified issues in practice result in a research agenda for modelling municipal solid waste logistics in Europe. We conclude that waste recycling is a multi-disciplinary problem that needs to be considered at different decision levels simultaneously. A holistic view and taking into account the characteristics of different waste types are necessary when modelling a reverse supply chain for MSW recycling. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Measurements for municipalities 2007

    NARCIS (Netherlands)

    B. Kuhry; J.J.J. Jonker; with participation of M. Ras

    2007-01-01

    Original title: Maten voor gemeenten 2007. Measurements for municipalities 2007 presents a national picture of the performance delivered by local authorities and the costs of doing so. The analyses relate to the period 2000-2005. This is the fifth time this quantitative and integrated picture

  12. Measurements for municipalities 2006

    NARCIS (Netherlands)

    B. Kuhry; J.J.J. Jonker; with cooperation of Bureau Zenc

    2006-01-01

    Original title: Maten voor gemeenten 2006. Measurements for municipalities 2006 (Maten voor gemeenten 2006) presents a national picture of the performance delivered by local authorities and the costs of doing so. The analyses relate to the period 1999-2004. This is the fourth time

  13. Measurements for municipalities 2012

    NARCIS (Netherlands)

    Evert Pommer; Ingrid Ooms; Ab van der Torre; Saskia Jansen

    2012-01-01

    Original title: Maten voor gemeenten 2012 Local authorities in the Netherlands are playing an ever more important role in the delivery of services to citizens, as more and more tasks are transferred from central to local government. Dutch municipalities spent a combined total of 56 billion

  14. A study of a desuperheater heat recovery system complete with a reversibly used water cooling tower (RUWCT) for hot water supply

    Science.gov (United States)

    Tan, Kunxiong

    Recovering heat rejected from the condenser in a refrigeration system to generate service hot water for buildings is commonly seen in both tropics and subtropics. This study included a critical literature review on heat recovery from air-conditioning/refrigeration systems, with particular emphasis on the direct condenser heat recovery and its related mathematical simulation models. The review identified many applications of desuperheaters to small-scaled residential air-conditioning or heat pump units. The heat and mass transfer characteristics of a RUWCT have been studied in detail, which is based on the theory of direct contact heat and mass transfer between moist air and water. The thesis reports on the differences in the heat and mass transfer process that takes place in a RUWCT, a standard water cooling tower and a spray room. A corrective factor that accounts for the change of chilled water mass flow rate is incorporated into the theoretical analysis of a RUWCT. The algorithms developed from the theoretical analysis are capable of predicting the heat exchange capacity of a RUWCT at any operating conditions. This theoretical analysis is the first of its kind. Extensive field experimental work on the heat and mass transfer characteristics of a RUWCT has been carried out in a hotel building in Haikou, Hainan province of China, where the RUWCT is installed. Results from the experimental work indicate that the theoretical analysis can represent the heat and mass transfer characteristics in a RUWCT with an acceptable accuracy. A numerical analysis for a RUWCT is undertaken to determine both air and water states at intermediate horizontal sections along the tower height. Field experimental data confirm that the predicted air and water conditions at the tower inlet and outlet are of acceptable accuracy. A steady-state mathematical model is developed to simulate the operational performance of a water chiller plant complete with a desuperheater heat recovery system and

  15. Fiscal 1974 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for existing detached houses); 1974 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. Kison kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-05-28

    This report describes the fiscal 1974 research result on solar cooling/heating and hot water supply systems for existing detached houses. The program for calculating heat collection rates was prepared by integrating peripheral conditions and every calculation step of heat collection rate, mean value, accumulated value and changes caused by disturbance. The cooling/heating load calculation program was also prepared for unsteady dynamic thermal analysis of houses. Another program was prepared for hot water supply load because of a large difference in life pattern. The profitability and energy conservation of 644 systems different in heat source, heat discharge, heat collection, heat storage, auxiliary heat source and equipment were evaluated by heat balance calculation program. Survey and study were also made on various heat engines such as heat pump, absorption refrigerator and Rankine cycle engine. Based on the survey result on existing technology for plane collectors, the optimum design method of collectors were established through various characteristic tests. Some kinds of suitable fusion latent heat type heat media were selected, and their operation stabilities were studied. (NEDO)

  16. Municipal solid waste generation in municipalities: quantifying impacts of household structure, commercial waste and domestic fuel.

    Science.gov (United States)

    Lebersorger, S; Beigl, P

    2011-01-01

    Waste management planning requires reliable data concerning waste generation, influencing factors on waste generation and forecasts of waste quantities based on facts. This paper aims at identifying and quantifying differences between different municipalities' municipal solid waste (MSW) collection quantities based on data from waste management and on socio-economic indicators. A large set of 116 indicators from 542 municipalities in the Province of Styria was investigated. The resulting regression model included municipal tax revenue per capita, household size and the percentage of buildings with solid fuel heating systems. The model explains 74.3% of the MSW variation and the model assumptions are met. Other factors such as tourism, home composting or age distribution of the population did not significantly improve the model. According to the model, 21% of MSW collected in Styria was commercial waste and 18% of the generated MSW was burned in domestic heating systems. While the percentage of commercial waste is consistent with literature data, practically no literature data are available for the quantity of MSW burned, which seems to be overestimated by the model. The resulting regression model was used as basis for a waste prognosis model (Beigl and Lebersorger, in preparation). Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Municipal solid waste generation in municipalities: Quantifying impacts of household structure, commercial waste and domestic fuel

    International Nuclear Information System (INIS)

    Lebersorger, S.; Beigl, P.

    2011-01-01

    Waste management planning requires reliable data concerning waste generation, influencing factors on waste generation and forecasts of waste quantities based on facts. This paper aims at identifying and quantifying differences between different municipalities' municipal solid waste (MSW) collection quantities based on data from waste management and on socio-economic indicators. A large set of 116 indicators from 542 municipalities in the Province of Styria was investigated. The resulting regression model included municipal tax revenue per capita, household size and the percentage of buildings with solid fuel heating systems. The model explains 74.3% of the MSW variation and the model assumptions are met. Other factors such as tourism, home composting or age distribution of the population did not significantly improve the model. According to the model, 21% of MSW collected in Styria was commercial waste and 18% of the generated MSW was burned in domestic heating systems. While the percentage of commercial waste is consistent with literature data, practically no literature data are available for the quantity of MSW burned, which seems to be overestimated by the model. The resulting regression model was used as basis for a waste prognosis model (Beigl and Lebersorger, in preparation).

  18. Application of multi-criteria decision-making model for choice of the optimal solution for meeting heat demand in the centralized supply system in Belgrade

    International Nuclear Information System (INIS)

    Grujić, Miodrag; Ivezić, Dejan; Živković, Marija

    2014-01-01

    The expected growth of living standard, number of inhabitants and development of technology, industry and agriculture will cause a significant increase of energy consumption in cities. Three scenarios of energy sector development until 2030 and corresponding energy consumption for the city of Belgrade are analyzed in this paper. These scenarios consider different level of economic development, investments in energy sector, substitution of fossil fuels, introduction of renewable energy sources and implementation of energy efficiency measures. The proposed model for selection of optimal district heating system compares different options for fulfilling expected new heat demand through eight criteria for each scenario. Proposed options are combination of different energy sources and technologies for their use. The criteria weights are set according to Serbian economy and energy position. The criteria include financial aspects, environmental impact and availability of energy. Multi-criteria method ELECTRE (ELimination Et Choix Traduisant la REalite) is used as a tool for obtaining the optimal option. It is concluded that combination of CHP (combined heat and power) plant and centralized use of geothermal energy is optimal choice in the optimistic scenario. In the pessimistic and business as usual scenario the optimal option is combination of new gas boilers and centralized use of geothermal energy. - Highlights: • Three scenarios for meeting new heat demand are developed and assessed. • Constructing CHP (combined heat and power) is desirable in case of significant electricity price growth. • In all scenarios the chosen option includes using geothermal energy for heating

  19. Criterion for selection of quasi-equilibrium and quasi-frozen flows of chemically reacting mixture N2O4 reversible 2NO2reversible 2NO+O2 with heat isobaric supply (removal)

    International Nuclear Information System (INIS)

    Kostik, G.Eh.; Shiryaeva, N.M.

    1979-01-01

    Is suggested the criterion of quasi-equilibrium and quasi-frozen flows with isobaric heat supply (removal), including the basic external factors, which affect on the kinetics of chemical process. This criterion is the complex [g/Fq], where g is the coolant rate, F is the channel cross-section, q is the heat flow. Estimated formulae for quasi-equilibrium [g/Fq]sub(e) and quasi-frozen [g/Fq]sub(f) flows are obtained. The states of deviation from equilibrium and frozen conditions in linear region are considered, are listed graphical dependences lg[g/Fq]sub(e), lg[g/Fq]sub(el), lg[g/Fq]sub(f), lg[g/Eq]sub(fl), as functions of equilibrium parameter Tsub(e), pressure and frozen coordinate of epsilonsub(2f) reaction. This graphs give the possibility to estimate rapidly and obviously the flow character of chemically reacting coolant

  20. Energy saving type area hot water supply system using heat of hot waste water from the sludge center as hot source for hot water; New energy rokko airando CITY. Surajjisenta karano onhaisuinetsu wo kyuyuyo netsugen ni riyosuru sho energy gata chiiki onsui kyokyu system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    Heat source of area hot water supply system in Rokko island City (man-made island) is heat of combustion at the sludge center (sludge incineration plant) in this island. Dehydrated sludge cakes (230ton/day) brought from seven sewage disposal plants in Kobe City is combusted (850degC) in the fluid bed hearth. Combustion gas washed in the scrubber, hot waste water after the washing give heat into heat transfer water in the first heat exchanger. Temperature being 64degC in summer and about 50degC in winter, this heat transfer water is sent into the second heat exchanger at every condominium building throughout the pipe line system circulating in the area. At each home, gas heater and hot water supply devices fitted, additional combustion is not necessary in summer but is used according to demand in other seasons. This hot water supply service has been carried out since 1988 and at present has been used by 3600 homes. Amount of supplying hot water being about 3000cu.m/day, saving is calculated roughly as 60% of gas for hot water supply. Fee for this system is 1500/yen/month uniformly for each home. 14 figs.

  1. District heating in Italy

    International Nuclear Information System (INIS)

    Sacchi, E.

    1998-01-01

    The legislative act establishing the electric monopoly virtually shut out the district heating associated with electricity cogeneration, while other laws, issued to counteract the effects of oil shocks, allowed municipal utilities to do so. Thus, district heating has experienced some development, though well below its possibilities. The article analyses the reasons for this lagging, reports district heating data and projects its forecasts against the Kyoto Protocol objectives [it

  2. Organic school meals in three Danish municipalities

    DEFF Research Database (Denmark)

    He, Chen

    In order to prevent children and young people from becoming overweight or obese, it is imperative to promote healthier eating patterns. So it is necessary to develop and implement effective strategies that can influence the eating and lifestyle habits of young people. Healthy school meal programme...... is considered to be an effective strategy to promote such changes and increasingly such strategies become embedded organic supply polices and strategies that pursue environmental goals. The purpose of this paper is to take a closer look into the current status of the organic school meal programme in Denmark....... Three municipalities which are involved in the organic school meal programme are chosen as the study subjects....

  3. Energy utilization: municipal waste incineration. Final report

    Energy Technology Data Exchange (ETDEWEB)

    LaBeck, M.F.

    1981-03-27

    An assessment is made of the technical and economical feasibility of converting municipal waste into useful and useable energy. The concept presented involves retrofitting an existing municipal incinerator with the systems and equipment necessary to produce process steam and electric power. The concept is economically attractive since the cost of necessary waste heat recovery equipment is usually a comparatively small percentage of the cost of the original incinerator installation. Technical data obtained from presently operating incinerators designed specifically for generating energy, documents the technical feasibility and stipulates certain design constraints. The investigation includes a cost summary; description of process and facilities; conceptual design; economic analysis; derivation of costs; itemized estimated costs; design and construction schedule; and some drawings.

  4. Organic school meals in three Danish municipalities

    DEFF Research Database (Denmark)

    He, Chen; Mikkelsen, Bent Egberg

    In order to prevent children and young people from becoming obese, healthier eating patterns are urgent. Organic school meals may be an effective strategy to provide healthy food to children. The purpose of this study was to take a closer look into the current status of organic school meal systems...... in Denmark, by conducting a case study of three municipalities in the Zealand region that have the most developed models for school meals service in this country. These municipalities have for some years introduced organic food for sale in their primary schools, with three quite different approaches....... Copenhagen has established a large central kitchen, producing partly organic food that is heated and sold in tuck shops at the schools. Roskilde cooperates with an organic catering company, delivering food to be sold in school canteens. Gladsaxe has part-time employed staff preparing and selling food at each...

  5. Case Studies in Low-Energy District Heating Systems: Determination of Dimensioning Methods for Planning the Future Heating Infrastructure

    DEFF Research Database (Denmark)

    Tol, Hakan; Nielsen, Susanne Balslev; Svendsen, Svend

    suggests a plan for an energy efficient District Heating (DH) system with low operating temperatures, such as 55°C supply and 25°C return; connected to low-energy buildings. Different case studies referring to typical DH planning situations could show the rational basis for the integrated planning...... of the future’s sustainable and energy efficient heating infrastructure. In this paper, a case study which focuses on dimensioning method of piping network of low-energy DH system in a new settlement, located in Roskilde Municipality, Denmark, is presented. In addition to the developed dimensioning method......, results about the optimal network layout and substation type for low-energy DH systems are also pointed out regarding to this case study. A second case study, included in this paper, focuses on technical and economical aspects of replacing natural gas heating system to low-energy DH system in an existing...

  6. Experimental study of the combined utilization of nuclear power heating plants for big towns and industrial complexes

    International Nuclear Information System (INIS)

    Neumann, J.; Barabas, K.

    1977-01-01

    The paper describes a comparison of nuclear power heating plants with an output corresponding to 1000MW(e) with plants of the same output using coal or oil. The economic aspects are compared, both as regards investment and operation costs. The comparison of the environmental aspects is performed on the atmospheric pollution from exhausts and gaseous emission and on the thermal pollutions in hydrosphere and atmosphere. Basic nuclear power plant schemes with two PWRs, each of 1500MW(th), are described. The plant supplies electric power and heat for factories and municipal heating systems (apartments, shops, and other auxiliary municipal facilities). At the same time the basic heat-flow diagram of a nuclear power heating plant is given, together with the relative losses. The study emphasizes the possible utilization of waste heat for heating glasshouses of 200m 2 . The problems of utilizing waste heat, and the needs of a big town and of industrial complexes in the vicinity of the nuclear power heating plant are also considered. (author)

  7. Municipal Solid Waste Resources

    Energy Technology Data Exchange (ETDEWEB)

    None

    2016-06-01

    Municipal solid waste (MSW) is a source of biomass material that can be utilized for bioenergy production with minimal additional inputs. MSW resources include mixed commercial and residential garbage such as yard trimmings, paper and paperboard, plastics, rubber, leather, textiles, and food wastes. Waste resources such as landfill gas, mill residues, and waste grease are already being utilized for cost-effective renewable energy generation. MSW for bioenergy also represents an opportunity to divert greater volumes of residential and commercial waste from landfills.

  8. Mercado municipal Can Vidalet

    OpenAIRE

    Romero Francisco, Jorge

    2006-01-01

    La intención del nuevo mercado municipal de Can Vidalet es crear un escenario en sombra, envuelto por una piel permeable; una "cesta" dentro de la cual se produce una actividad comercial. La topografía del lugar permite establecer un esquema comercial en sección, situando el mercado tradicional en cota superior y el nuevo uso comercial en planta baja, a nivel de plaza pública.

  9. Use of hydrogeothermal energy to support traditional heat supply systems; Nutzung der Energie von geothermalen Gewaessern zur Unterstuetzung der traditionellen Waermeversorgungssysteme

    Energy Technology Data Exchange (ETDEWEB)

    Kabat, M; Nowak, W; Sobanski, R [Technische Univ., Szczecin (Poland)

    1997-12-01

    In the Szczecin Region, there are considerable resources of geothermal waters with temperatures from about 30 to 120 C. The authors present in their paper, on the example of selected urban centres, a possibility of utilising geothermal energy for modernisation of traditional heating systems. Among others, the idea of using geothermal energy in combination with conventional heat and power plants has been discussed and the geothermal heating system in Pyrzyce commissioned in February 1996 has been presented. (orig.) [Deutsch] In der Woiwodschaft-Szczecin sind betraechtliche Vorraete der geothermalen Gewaesser mit den Temperaturen von 30 bis ca. 120 C vorhanden. Im vorliegenden Referat stellen die Autoren am Beispiel einiger staedtischer Gebiete die Moeglichkeit, die geothermale Energie zur Modernisierung der traditionellen Waermeversorgungssysteme zu nutzen. Unter anderem wurde das Nutzungskonzept der geothermalen Waermequelle gekopplelt mit konventionellen Heizkraftwerken beschrieben und das im Februar 1996 in Betrieb genommene geothermale Waermeversorgungssysteme in Pyrzyce praesentiert. (orig.)

  10. Laboratory stand for examination of the operational thermal parameters of polyvalent system for heating, cooling and domestic hot water supply using renewable energy sources

    International Nuclear Information System (INIS)

    Zlateva, Merima

    2014-01-01

    The report presents the structure of an universal laboratory stand for determine the operating parameters of a polyvalent system for utilization of renewable energy sources. The system is a combination of three modules using different technologies for renewable sources – solar energy, atmospheric air and biomass, incorporated in a common heat accumulator. The structural scheme permits the possibility to use the stand in different operating modes, to demonstrate the feasibility of using any one of the renewable energy sources both individually and in various combinations. The author express gratitude to the partners of the companies Robert Bosch Bulgaria Ltd, Ahi Carrier Bulgaria and Eratermtotal, with whose generous support is build the stand. Key words: Renewable energy sources (RES), Heating with RES, Biomass, Air to Water Heat pumps

  11. AGFW. Main report of the district heat supply 1996; AGFW. Hauptbericht der Fernwaermeversorgung 1996. Technische Daten zur Fernwaermeversorgung in Deutschland 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-01

    A total of 232 district heating companies participated in the main report of district heating 1996. See the table for the distribution of corporate data per federal state (orig.) [Deutsch] Die in Tafeln 1 bis 15 ausgewiesenen Zahlen beziehen sich auf Angaben, die von der AGFW direkt bei den Unternehmen erhoben wurden. Seit 1995 werden die Angaben, die im Ostteil von Berlin erhoben wurden, dem Bundesland Berlin mit der Kennziffer 11 zugeordnet. Die AGFW bedankt sich bei den Unternehmen fuer die gute Zusammenarbeit (orig.)

  12. District heating rehabilitation project in Kaerdla on Hiiumaa, Estonia. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The main objective of the project has been to assist Kaerdla Municipality with the rehabilitation of their district heating system with Danish technology, and thereby support and make it possible for the Municipality of Kaerdla to develop the district heating sector in Kaerdla and thereby also to reduce emissions of harmful gases to the environment, as well as making a much more rational and energy efficient system. The project would further on demonstrate the use of pre-insulated pipes, which are fully sealed against penetration of water as well as demonstrate the use of compact units as substations including weather compensation control systems for regulation of heat and hot tap water supply for the district heating consumers. Besides the project gives significantly decreases in energy consumption`s and in the pollution from the production of energy, the objective of the project was also to put great stress on providing technical assistance to Kaerdla DH company, in order to make them capable in operation and maintenance of the new district heating system, and also to train the local operational staff in operation of the complete district heating system. The project will have a high demonstration value towards other towns in Estonia with similar problems and configurations of their heating systems. (EG)

  13. District heating rehabilitation project in Kaerdla on Hiiumaa, Estonia. Final report

    International Nuclear Information System (INIS)

    1998-03-01

    The main objective of the project has been to assist Kaerdla Municipality with the rehabilitation of their district heating system with Danish technology, and thereby support and make it possible for the Municipality of Kaerdla to develop the district heating sector in Kaerdla and thereby also to reduce emissions of harmful gases to the environment, as well as making a much more rational and energy efficient system. The project would further on demonstrate the use of pre-insulated pipes, which are fully sealed against penetration of water as well as demonstrate the use of compact units as substations including weather compensation control systems for regulation of heat and hot tap water supply for the district heating consumers. Besides the project gives significantly decreases in energy consumption's and in the pollution from the production of energy, the objective of the project was also to put great stress on providing technical assistance to Kaerdla DH company, in order to make them capable in operation and maintenance of the new district heating system, and also to train the local operational staff in operation of the complete district heating system. The project will have a high demonstration value towards other towns in Estonia with similar problems and configurations of their heating systems. (EG)

  14. Heat supply and climate protection in housing associations. State of the art, perspective demands, action alternatives; Waermeversorgung und Klimaschutz in Wohnungsunternehmen. Aktueller Stand, Perspektivische Anforderungen, Handlungsalternativen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-04-15

    In recent years, problems of energy supply and climate change in the housing association increasingly gain a higher importance. These problems are a central issue in dealing with demands arising from changing demographics, increasing prices for energy and new statutory provisions for environmental protection among other things. According to this situation, this brochure provides information, ideas, experiences and proposals such as an efficient integration and permanent placement of energy and climate change into the apartment management.

  15. Municipal hydraulic planning for energy saving; Planeacion hidraulica municipal para el ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Garcia, Enrique [PTF S.C. Consultores, Leon, Gto. (Mexico)

    1999-07-01

    The efficient handling of the economic and natural resources of the municipalities, is nowadays so much complex, that it requires a formal planning. In the public service of potable water supply, two fundamental approaches are conjugated to consider: the rational use of the water resource and the efficient use of the electrical energy, for its extraction from the underground deep reservoirs. In the paper that is presented, the individual features of the previous matters are described and the positive results in a municipality of the Guanajuato's Low Lands (Bajio ), where already the dual objectives are obtained and that with a more professional municipal hydraulic planning, these will be permanent, with the inherent benefit towards the population. [Spanish] El manejo eficiente de los recursos economicos y naturales de los municipios, es hoy en dia cada vez mas complejo, que requiere una planeacion formal. En el servicio publico de abastecimiento de agua potable, se conjugan dos enfoques primordiales a considerar: el uso racional del recurso agua y la utilizacion eficiente de la energia electrica, para su extraccion de los acuiferos subterraneos profundos. En el trabajo que se presenta, se describen las particularidades de lo anterior y los resultados positivos en un municipio del Bajio guanajuatense, donde ya se logran los objetivos duales y que con una planeacion hidraulica municipal mas profesional, estos seran permanentes, con el beneficio inherente hacia la poblacion.

  16. Study of solar energy utilization for the needs of municipal equipments of the city of Tunis

    Energy Technology Data Exchange (ETDEWEB)

    Cassou, J; Potron, A

    1982-08-01

    This report presents the main ways of utilization of solar energy in Tunisia: hot sanitary water, active solar space heating and bioclimatism. Several municipal installations (municipal showers, kindergartens, sport complexes, townhall...) have been visited and one gives the actions which have been suggested for these ones.

  17. Thermal construction unit activation with supply air gains significance. Ceilings cooling - supply air heating - more than 50 % energy conservation; Thermische Bauteilaktivierung mit Zuluft gewinnt an Bedeutung. Decke kuehlen - Zuluft erwaermen - mehr als 50% Energie einsparen

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Wolfgang

    2009-05-15

    In the year 2001, in Stuttgart (Federal Republic of Germany) the first office building was established which uses a thermal construction unit activation with air as cooling agent. Today, the system ''Concret-cool'' already is installed in more than 40 buildings. Computations show that due to the room heating by means of internally finned ventilation pipes embedded in concrete more than 50 % less energy in comparison to comparable systems can be used. In his Green Building project ''Skyline Tower'' in Munich (Federal Republic of Germany), also star architect Helmut Jahn uses the know-how of the manufacturer of ventilation systems from Stuttgart. As one of the first multi-storied buildings in Munich, ''Skyline Tower'' with its 23 floors was prized with the pre-certificate of the German quality seal ''sustainable building ''in gold.

  18. Desempenho tecnológico dos serviços de abastecimento de água e esgotamento sanitário em quatro municípios de Minas Gerais: uma análise comparativa Technological performance of water supply and sanitation services in four municipalities in Minas Gerais, Brazil: a comparative analysis

    Directory of Open Access Journals (Sweden)

    Pedro Gasparini Barbosa Heller

    2009-03-01

    Full Text Available Indicadores tecnológicos representam uma importante forma de avaliar a quantidade e a qualidade dos serviços de saneamento prestados à população. Com essa perspectiva, o artigo apresenta metodologia quali-quantitativa, visando à comparação do desempenho tecnológico de serviços de água e esgotos. O modelo é constituído por indicadores de desempenho que, combinados por meio de análise multicritério (modelo TOPSIS, propiciam uma hierarquização da qualidade tecnológica dos serviços. Aplica-se a metodologia aos municípios de Itabirito, Ouro Preto, Nova Lima e Vespasiano (Minas Gerais. Buscando explorar as particularidades do desempenho de cada serviço, os resultados permitem identificar diferenças tecnológicas significativas entre eles, reveladas nos aspectos de cobertura por redes, controle de perdas, qualidade da água, estações de tratamento, tarifas, entre outros.Technological indicators are important tools for the assessment of quantity and quality of the environmental sanitation services provided for the population. From this perspective, this paper presents a quali-quantitative methodology intending to compare technological performance of water supply and sanitation services. The method consists of performance indicators that, combined trough a multicriterion model (TOPSIS, enable the hierarchization of the technological quality of services. The model is applied at the municipalities of Itabirito, Ouro Preto, Nova Lima and Vespasiano (Minas Gerais, Brazil. Exploring particularities of each service performance, the results suggest significant technological differences between the services, based on aspects of coverage, water loss control, water quality, treatment plants, tariffs, etc.

  19. Heat Roadmap Europe

    DEFF Research Database (Denmark)

    Connolly, David; Lund, Henrik; Mathiesen, Brian Vad

    2014-01-01

    compared to 1990 levels. None of these scenarios involve the large-scale implementation of district heating, but instead they focus on the electrification of the heating sector (primarily using heat pumps) and/or the large-scale implementation of electricity and heat savings. In this paper, the potential...... for district heating in the EU between now and 2050 is identified, based on extensive and detailed mapping of the EU heat demand and various supply options. Subsequently, a new ‘district heating plus heat savings’ scenario is technically and economically assessed from an energy systems perspective. The results...... indicate that with district heating, the EU energy system will be able to achieve the same reductions in primary energy supply and carbon dioxide emissions as the existing alternatives proposed. However, with district heating these goals can be achieved at a lower cost, with heating and cooling costs...

  20. Investigation of the foreign market for commercial wood gasification systems for the production of cogenerated heat and electricity, especially for the purpose of the establishment of a plant at Herning municipal works; Undersoegelse af det udenlandske marked for kommercielle traeforgasningsanlaeg til kraftvarmeproduktion, specielt med henblik paa opfoerelse af et anlaeg hos Herning Kommunale Vaerker

    Energy Technology Data Exchange (ETDEWEB)

    1992-07-01

    The local authorities at Herning (Denmark) wished to be able to offer the local inhabitants heat supply from a district heating plant based on local energy resources. The projects consists of an investigation of the markets abroad (represented by 64 institutions and firms) for a gasification technology that could be used in relation to locally produced wood fuels. The efficiency of the gasifier and demands on the type of fuel was also considered. Detailed reports and evaluations of the design and techniques offered are presented in relation to visits to relevant firms in England, France, Holland and Germany. (AB)

  1. The prospects for nuclear heating in Hungary

    International Nuclear Information System (INIS)

    Lynch, G.F.; Papp, I.

    1989-09-01

    Hungary supplies only half of its energy requirements from domestic resources and is very dependent upon imports of oil, natural gas and electricity to meet the current demand. In planning to reduce the dependence on imports, nuclear technology is considered an important element in the long-term energy strategy. To this end, an aggressive nuclear electricity generation program is being implemented with four 440 MWe units now operating and two 1000 MWe units committed. However, nuclear technology must be used in other energy sectors if the goal of long-term energy independence is to be achieved. On the demand side, 30% of the primary energy is consumed in the public sector, the major component being residential heating. Of the 3.7 million apartments in Hungary, 500 000 benefit from being connected to municipal district heating systems that use natural gas or oil as the energy base. This is, therefore, another significant energy sector that is amenable to using nuclear technology to substitute for imported oil and natural gas. In assessing alternative nuclear heat sources, a joint study was undertaken between Canada and Hungary to determine the feasibility of using the SLOWPOKE Energy System that has recently been developed. The SLOWPOKE Energy System is a benign nuclear heat source designed to supply 10 thermal megawatts in the form of hot water for local heating systems in buildings and institutions. It uses a combination of inherent safety features, including natural convection circulation and negative reactivity coefficients, and engineered features to ensure an extremely safe system. A SLOWPOKE demonstration heating reactor has been constructed in Canada. The unit started operation in 1987 July and is currently undergoing an extensive test program

  2. Multi-criteria assessment of technologies for electricity and heat supply; Multikriterielle Bewertung von Technologien zur Bereitstellung von Strom und Waerme

    Energy Technology Data Exchange (ETDEWEB)

    Oberschmidt, Julia

    2010-08-26

    The present thesis deals with how decisions concerning the future energy supply can be effectively, transparently and comprehensibly supported, against the backdrop of sometimes conflicting objectives. The relevance of the question is first of all explained in the context of important framework conditions for decisions in the energy sector. Subsequently, the most significant technology paths which already contribute to today''s energy supply or represent potential future options are shown. However, none of these options alone can meet the demands for a cost-effective, environmentally friendly and reliable energy supply. Rather, their strengths and weaknesses should be carefully weighed against each other in the light of the specific framework conditions. This gives rise to the need for a multi-criteria decision-making support tool, in order to be able to evaluate energy technologies while simultaneously comparing and considering several objectives. An in-depth analysis of known applications of multi-attribute methods in the energy sector shows that methods for multi-attribute decision aiding are already established in the energy industry and energy policy. Weaknesses of known applications lie primarily in the fact that in many cases technological change has not yet been adequately addressed. Therefore, in the present thesis a multi-criteria method is developed which allows established and innovative technologies to be systematically compared, together with the consideration of criteria weighting depending on different technology cycle phases. The proposed method is implemented in a decision support system (DSS), which is validated using two case studies. In the first case study, alternative energy supply concepts for a bio-energy village are compared. In the second case study, technologies for stationary electricity storage are compared. The results show that criteria weightings depending on varying technology cyclephases produce different results than from an

  3. Multi-criteria assessment of technologies for electricity and heat supply; Multikriterielle Bewertung von Technologien zur Bereitstellung von Strom und Waerme

    Energy Technology Data Exchange (ETDEWEB)

    Oberschmidt, Julia

    2010-08-26

    The present thesis deals with how decisions concerning the future energy supply can be effectively, transparently and comprehensibly supported, against the backdrop of sometimes conflicting objectives. The relevance of the question is first of all explained in the context of important framework conditions for decisions in the energy sector. Subsequently, the most significant technology paths which already contribute to today''s energy supply or represent potential future options are shown. However, none of these options alone can meet the demands for a cost-effective, environmentally friendly and reliable energy supply. Rather, their strengths and weaknesses should be carefully weighed against each other in the light of the specific framework conditions. This gives rise to the need for a multi-criteria decision-making support tool, in order to be able to evaluate energy technologies while simultaneously comparing and considering several objectives. An in-depth analysis of known applications of multi-attribute methods in the energy sector shows that methods for multi-attribute decision aiding are already established in the energy industry and energy policy. Weaknesses of known applications lie primarily in the fact that in many cases technological change has not yet been adequately addressed. Therefore, in the present thesis a multi-criteria method is developed which allows established and innovative technologies to be systematically compared, together with the consideration of criteria weighting depending on different technology cycle phases. The proposed method is implemented in a decision support system (DSS), which is validated using two case studies. In the first case study, alternative energy supply concepts for a bio-energy village are compared. In the second case study, technologies for stationary electricity storage are compared. The results show that criteria weightings depending on varying technology cyclephases produce different results than

  4. Strategic Supply

    National Research Council Canada - National Science Library

    Alexander, Kelly; Cole, Heather; Cural, Ahmet; Daugherty, Darryl; Howard, Russell; Keane, Thomas; Louie, K. Y; McNeely, Rosa; Mordente, Patrick; Petrillo, Robert

    2006-01-01

    ...; but rather, as an enabler across all industries. Therefore, this industry study looked at Strategic Supply as an integrated process performed by industries to obtain comparative and competitive advantage in the global marketplace...

  5. Strategic Supply

    National Research Council Canada - National Science Library

    Alexander, Kelly; Cole, Heather; Cural, Ahmet; Daugherty, Darryl; Howard, Russell; Keane, Thomas; Louie, K. Y; McNeely, Rosa; Mordente, Patrick; Petrillo, Robert

    2006-01-01

    .... The Council of Supply Chain Management Professionals (CSCMP) has defined SCM as,"...encompassing the planning and management of all activities involved in sourcing and procurement, conversion, and all Logistics Management activities...

  6. Towards a more sustainable heat supply for the built environment in 2050; Naar een duurzamere warmtevoorziening van de gebouwde omgeving in 2050

    Energy Technology Data Exchange (ETDEWEB)

    Van den Wijngaart, R.A.; Folkert, R.J.M.; Elzenga, H.E.

    2012-04-15

    To curb the CO2 emission of the built environment, a combination of building and environment oriented measures is most efficient. Together, they can reduce the CO2 emission with 15 to 30 per cent. This has financial benefits and leads to larger CO2 reduction in 2050 compared to measures focusing on buildings alone such as insulation or more efficient heating or on environment oriented measures (such as waste heat, geothermal or thermal energy storage) [Dutch] Om de CO2-uitstoot van de gebouwde omgeving te beperken, is een combinatie van gebouw- en gebiedsmaatregelen het meest efficient. Samen kunnen ze voor 15 tot 30 procent minder CO2-uitstoot zorgen. Het is financieel voordelig en levert in 2050 een grotere CO2-reductie op dan het nemen van alleen gebouwmaatregelen zoals isolatie of efficientere verwarmingsinstallaties of alleen gebiedsmaatregelen (zoals restwarmte, geothermie of warmte-koudeopslag)

  7. Innovation Management in Swedish Municipalities

    OpenAIRE

    Wihlman, Thomas; Hoppe, Magnus; Wihlman, Ulla; Sandmark, Hélène

    2016-01-01

    Research on public sector innovation is still limited, and increased knowledge of innovation processes is needed. This article is a based on a study of the implementation of innovation policies in Swedish municipalities, and gives a first-hand, empirical view of some of the complexities of innovation in the public sector. The study took place in four municipalities in central Sweden. The municipalities varied in size and organisational forms. Interviews and policy documents were used for data...

  8. Water supply

    International Nuclear Information System (INIS)

    Peterson, F.L.

    1986-01-01

    Options and methodologies for the development of fresh water supplies on Bikini Atoll are much the same as those practiced in the rest of the Marshall Islands and for that matter, most atolls in the central Pacific Ocean Basin. That is, rainfall distribution on Bikini produces a distinct wet season, lasting from about May through November, with the remaining months being generally dry. As a result, fresh water from surface catchments tends to be plentiful during the wet season? but is usually scarce during the dry months, and alternative sources such as groundwater must be utilized during this time. On Bikini the problems of fresh water supply are somewhat more difficult than for most Marshall Island atolls because rainfall is only about half the Marshall Island's average. Tus water supply is a critical factor limiting the carrying capacity of Bikini Atoll. To address this problem BARC has undertaken a study of the Bikini Atoll water supply. Te primary objectives of this work are to determine: (1) alternatives available for fresh water supply, 2 the amounts, location and quality of available supplies and 3 optimal development methods. The study planned for one's year duration, has been underway only since the summer of 1985 and is thus not yet fully completed. However, work done to date, which is presented in this report of preliminary findings, provides a reasonably accurate picture of Bikini's fresh water supplies and the various options available for their development. The work remaining to be completed will mainly add refinements to the water supply picture presented in the sections to follow

  9. Physical and chemical parameter correlations with technical and technological characteristics of heating systems and the presence of Legionella spp. in the hot water supply.

    Science.gov (United States)

    Rakić, Anita; Štambuk-Giljanović, Nives

    2016-02-01

    The purpose of this study was to evaluate the prevalence of Legionella spp. and compare the quality of hot water between four facilities for accommodation located in Southern Croatia (the Split-Dalmatian County). The research included data collection on the technical and technological characteristics in the period from 2009 to 2012. The survey included a type of construction material for the distribution and internal networks, heating system water heater type, and water consumption. Changes in water quality were monitored by determination of the physical and chemical parameters (temperature, pH, free chlorine residual concentrations, iron, zinc, copper and manganese) in the samples, as well as the presence and concentration of bacteria Legionella spp. The temperature is an important factor for the development of biofilms, and it is in negative correlation with the appearance of Legionella spp. Positive correlations between the Fe and Zn concentrations and Legionella spp. were established, while the inhibitory effect of a higher Cu concentration on the Legionella spp. concentration was proven. Legionella spp. were identified in 38/126 (30.2%) of the water samples from the heating system with zinc-coated pipes, as well as in 78/299 (26.1%) of the samples from systems with plastic pipes. A similar number of Legionella spp. positive samples were established regardless of the type of the water heating system (central or independent). The study confirms the necessity of regular microbial contamination monitoring of the drinking water distribution systems (DWDSs).

  10. trace element determination in municipal water supply of Damaturu

    African Journals Online (AJOL)

    DR. AMINU

    been attributed to human interference, proliferation of industries, and recent ... to chickens for disease management. Similarly, pig ... depends mainly on underground water resources which are .... G.G. (2004). General Chemistry 7th Edition.

  11. Thermodynamic, ecological and economic aspects of the use of the gas turbine for heat supply to the stripping process in a supercritical CHP plant integrated with a carbon capture installation

    International Nuclear Information System (INIS)

    Bartela, Łukasz; Skorek-Osikowska, Anna; Kotowicz, Janusz

    2014-01-01

    Highlights: • Variants of integration of CHP plant with CCS and gas turbine unit were analyzed. • The simulations of operation of plants under changing load were realized. • Conditions of competitiveness for all solutions were identified. • Integration can be profitable if prices of allowance will reach values >60 €/MgCO 2 . - Abstract: This paper presents the results of thermodynamic and economic analyses for eight variants of a combined heat and power (CHP) plant fuelled with coal working under supercritical steam parameters and integrated with a CO 2 capture installation and a gas turbine system. The motivation behind using a gas turbine in the system was to generate steam to supply heat for the stripping process that occurs in the separation installation to regenerate the sorbent. Additional analyses were conducted for the reference case, a CHP unit in which the CO 2 separation process was not conducted, to enable an economic evaluation of the integration of a CHP unit with a CO 2 separation installation according to the variants proposed. The break-even price of electricity and avoided emission costs were used to evaluate the respective solutions. In this paper, the results of the sensitivity analysis of the economic evaluation indicators in terms of the change in the annual operation time, price of emission allowance and heat demand rate for the realization of the stripping process for all cases are presented

  12. Intersectoriality in Danish municipalities

    DEFF Research Database (Denmark)

    Heering Holt, Ditte; Frohlich, Katherine L; Tjørnhøj-Thomsen, Tine

    2017-01-01

    healthier practices into various settings, e.g. creating healthy school environments for increased physical activity and healthy eating. While other more overarching interventions on the health impacts of broader welfare policies (e.g. education policy) tend to be neglected. The interventions hereby neglect...... the intersectoral policy process legitimates certain practices in the setting of Danish municipal health promotion and the potential impact this can have for long-term, sustainable healthy public policy. Based on ethnographic fieldwork, we show how the intention of intersectoriality produces a strong concern...

  13. Renewable energy in district heating grids. A realistic perspective?; Erneuerbare Energien in Waermenetzen. Eine realistische Perspektive?

    Energy Technology Data Exchange (ETDEWEB)

    Bruns, Elke [Technische Univ. Berlin (Germany). Inst. fuer Landschaftsarchitektur und Umweltplanung; Futterlieb, Matthias; Ohlhorst, Doerte [Technische Univ. Berlin (Germany). Zentrum Technik und Gesellschaft (ZTG); Wenzel, Bernd [Ingenieurbuero fuer neue Energie (IfnE), Teltow (Germany)

    2012-09-15

    The heating sector holds high potentials for cutting CO{sub 2} emissions by using renewable energy. These potentials can be tapped either by substituting fossil fuels in individual heating units or by using renewable energy in district heating networks, which may be more efficient. This paper asks for the options to increase the share of renewable energy in Germany's district heating infrastructure and for the restrictions that are hampering further development in this field. It critically discusses the relevant technical, political and economic challenges and determinants. District heating networks fuelled by renewable energy are not only competing with fossil fuels in individual heating units. They are also facing the more fundamental question regarding the preconditions for a profitable and worthwhile operation of grid-bound heat supply. The economic viability of heat grids has to be analyzed on a case-by-case basis, since it depends predominantly on individual framework conditions. Those include a decreasing heat demand due to improving energy performance of buildings, competing gas grids already in place and the complex interest structures of the actors involved. The growth rates that were observed in the last years were predominantly achieved in small renewably fuelled district heating networks. Even under favourable framework conditions, there is a need for additional supportive measures to increase the share of renewable energy in district heating grids. This mix of policy instruments should encompass measures to increase the implementation rates of municipal heat utilization concepts, measures to decrease the initial investments needed, as well as public relations to improve the user perception of grid-bound heat supply. However, the options to increase the share of renewable heat in existing large-scale grids are considered to be rather limited. (orig.)

  14. Income generation in the supply chain of acai in the design of electric energy supply in isolated communities in the municipality of Manacapuru, AM; Geracao de renda na cadeia produtiva do acai em projeto de abastecimento de energia eletrica em comunidades isoladas no Municipio de Manacapuru-AM

    Energy Technology Data Exchange (ETDEWEB)

    Bacellar, Atlas A; Souza, Rubem C.R.; Xavier, Diogo J.C.; Seye, Omar; Bacellar, Atlas A; Santos, Eyde C.S.; Freitas, Katriana T. [Universidade Federal do Amazonas (CDEAM/UFAM), Manaus, AM (Brazil). Centro de Desenvolvimento Energetico Amazonico], Email: abacellar@ufam.edu.br

    2006-07-01

    Efforts endeavored by the State aiming to universalize the electricity use in Brazil, PRODEEM and Programa Luz Para Todos are examples of it, had have as result high insolvency or interruption. The aim of this work is to analyze the potentialities of increasing incomes in communities at the city of Manacapuru - AM, assisted by the research project 'Model of electric power Businesses in Isolated Communities at the Amazon region'- NERAM, under the responsibility of CDEAM of Federal University of Amazonas - UFAM, starting from acai supply chain. The strategy is to implement an industry of acai's pulps with the objectives of adding value to the fruit and to use the pits as biomass to generate power. Cooperative as a legal model of enterprise was adopted in order to be responsible for the industry with the participation of the families that work with the fruit and the community in general. The cooperative plant idealized was based on the report of a socioeconomic research applied at the communities. Three methods were used to analyze the investment: Uniform Annual Value Equivalent, Liquid Present Value and Ratio of Internal Return. The results demonstrated the enterprise's viability since obeying the following premises: 50 tons of minimum production of acai per month; R$ 2.50 as a minimum pulp's sale price; and 0.60 kg of pulp for 1 kg of fruit as minimum productivity, which will create nine new puts of work, warranty of acai's fruit sale, income's increasing for the cooperative and incentive to catch the fruit. (author)

  15. Local business models for district heat production; Kaukolaemmoen paikalliset liiketoimintamallit

    Energy Technology Data Exchange (ETDEWEB)

    Hakala, L.; Pesola, A.; Vanhanen, J.

    2012-12-15

    Local district heating business, outside large urban centers, is a profitable business in Finland, which can be practiced with several different business models. In addition to the traditional, local district heating business, local district heat production can be also based on franchising business model, on integrated service model or on different types of cooperation models, either between a local district heat producer and industrial site providing surplus heat or between a local district heat producer and a larger district heating company. Locally available wood energy is currently utilized effectively in the traditional district heating business model, in which a local entrepreneur produces heat to consumers in the local area. The franchising model is a more advanced version of the traditional district heating entrepreneurship. In this model, franchisor funds part of the investments, as well as offers centralized maintenance and fuel supply, for example. In the integrated service model, the local district heat producer offers also energy efficiency services and other value-added services, which are based on either the local district heat suppliers or his partner's expertise. In the cooperation model with industrial site, the local district heating business is based on the utilization of the surplus heat from the industrial site. In some cases, profitable operating model approach may be a district heating company outsourcing operations of one or more heating plants to a local entrepreneur. It can be concluded that all business models for district heat production (traditional district heat business model, franchising, integrated service model, cooperative model) discussed in this report can be profitable in Finnish conditions, as well for the local heat producer as for the municipality - and, above all, they produce cost-competitive heat for the end-user. All the models were seen as viable and interesting and having possibilities for expansion Finland

  16. District heating rehabilitation project. Viljandi - Estonia. Final report

    International Nuclear Information System (INIS)

    1998-04-01

    The main objective of the project has been to assist Viljandi Municipality with the rehabilitation of their district heating system, and thereby to support the positive development of the district heating system in Viljandi to a more energy efficient and rational system and to achieve a significantly decrease in the pollution from the production of heat energy in Viljandi. The project has also included technical assistance to Viljandi DH company, in order to make them capable of operation and maintaining of the new substations, and also training of the local operational staff for operation of the complete district heating system. Viljandi is a county and is centrally located in Estonia, which makes Viljandi very suitable as recipient for a demonstration project. One important objective was the projects significantly positive environmental impact in reduction of the generated emissions of CO 2 , NO x and SO 2 , as the project includes installation of more efficient energy systems and supply of heat from the 2 existing district heating plants (both are partly fired with wood chips) instead of heating by very old and worn-out coal fired boilers and inexpedient designed substations with the present operational conditions. (EG)

  17. District heating rehabilitation project. Viljandi - Estonia. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    The main objective of the project has been to assist Viljandi Municipality with the rehabilitation of their district heating system, and thereby to support the positive development of the district heating system in Viljandi to a more energy efficient and rational system and to achieve a significantly decrease in the pollution from the production of heat energy in Viljandi. The project has also included technical assistance to Viljandi DH company, in order to make them capable of operation and maintaining of the new substations, and also training of the local operational staff for operation of the complete district heating system. Viljandi is a county and is centrally located in Estonia, which makes Viljandi very suitable as recipient for a demonstration project. One important objective was the projects significantly positive environmental impact in reduction of the generated emissions of CO{sub 2}, NO{sub x} and SO{sub 2}, as the project includes installation of more efficient energy systems and supply of heat from the 2 existing district heating plants (both are partly fired with wood chips) instead of heating by very old and worn-out coal fired boilers and inexpedient designed substations with the present operational conditions. (EG)

  18. Energy costs and Portland water supply system

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, W.M.; Hawley, R.P.

    1981-10-01

    The changing role of electrical energy on the Portland, Oregon, municipal-water-supply system is presented. Portland's actions in energy conservation include improved operating procedures, pump modifications, and modifications to the water system to eliminate pumping. Portland is implementing a small hydroelectric project at existing water-supply dams to produce an additional source of power for the area. Special precautions in construction and operation are necessary to protect the high quality of the water supply. 2 references, 7 figures.

  19. Income generation in the supply chain of acai in the design of electric energy supply in isolated communities in the municipality of Manacapuru, AM; Geracao de renda na cadeia produtiva do acai em projeto de abastecimento de energia eletrica em comunidades isoladas no Municipio de Manacapuru-AM

    Energy Technology Data Exchange (ETDEWEB)

    Bacellar, Atlas A.; Souza, Rubem C.R.; Xavier, Diogo J.C.; Seye, Omar; Bacellar, Atlas A.; Santos, Eyde C.S.; Freitas, Katriana T. [Universidade Federal do Amazonas (CDEAM/UFAM), Manaus, AM (Brazil). Centro de Desenvolvimento Energetico Amazonico], Email: abacellar@ufam.edu.br

    2006-07-01

    Efforts endeavored by the State aiming to universalize the electricity use in Brazil, PRODEEM and Programa Luz Para Todos are examples of it, had have as result high insolvency or interruption. The aim of this work is to analyze the potentialities of increasing incomes in communities at the city of Manacapuru - AM, assisted by the research project 'Model of electric power Businesses in Isolated Communities at the Amazon region'- NERAM, under the responsibility of CDEAM of Federal University of Amazonas - UFAM, starting from acai supply chain. The strategy is to implement an industry of acai's pulps with the objectives of adding value to the fruit and to use the pits as biomass to generate power. Cooperative as a legal model of enterprise was adopted in order to be responsible for the industry with the participation of the families that work with the fruit and the community in general. The cooperative plant idealized was based on the report of a socioeconomic research applied at the communities. Three methods were used to analyze the investment: Uniform Annual Value Equivalent, Liquid Present Value and Ratio of Internal Return. The results demonstrated the enterprise's viability since obeying the following premises: 50 tons of minimum production of acai per month; R$ 2.50 as a minimum pulp's sale price; and 0.60 kg of pulp for 1 kg of fruit as minimum productivity, which will create nine new puts of work, warranty of acai's fruit sale, income's increasing for the cooperative and incentive to catch the fruit. (author)

  20. Local democracy in large municipalities

    DEFF Research Database (Denmark)

    Thuesen, Annette Aagaard

    2017-01-01

    Municipal amalgamations in Denmark in 2007 led to concern for local rural democracy, as the number of politicians from rural areas dropped after the reform. To preserve rural democracy, local councils at the village level were established in some municipalities, and they have begun to prepare local...

  1. Adaptive Municipal e-forms

    NARCIS (Netherlands)

    Kuiper, P.M.; van Dijk, Elisabeth M.A.G.; Boerma, A.K.; Weibelzahl, S.; Cristea, A.

    2006-01-01

    Adaptation of electronic forms seems to be a step forward to reduce the burden for people who fill in forms. Municipalities more and more offer eforms online that can be used to request a municipal product or service. To create adaptive e-forms that satisfy the need of end-users, involvement of

  2. Study on Municipal Energy Companies

    International Nuclear Information System (INIS)

    2009-07-01

    This is a summarizing overview of the local, renewable energy initiatives that are grouped under the heading of 'municipal energy company'. A municipal energy company (or sustainable energy company) is a local energy company that initiates, coordinates and/or manages sustainable energy projects with the primary objective of realizing the climate objectives. [nl

  3. Health improvement of domestic hot tap water supply Gusev, Kaliningrad Region, Russia. Make-up water tank project. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Aagaard, Joergen

    1998-07-01

    This report describes the project `Health Improvement of Domestic Hot Tap Water Supply, Gusev, Kaliningrad, Russia`, which was carried out in the autumn of 1996 and financed by the Danish Environmental Protection Agency, the Danish Energy Agency and Gusev Municipality. The project proposal and application outlined the following objectives: Erection of system so that hot tap water, which is tapped directly from the district heating system, obtains an acceptable quality in health terms; Complete training and education, so that the plant can be operated and maintained by the power station`s staff and rehabilitation projects within supply of domestic water and district heating can be promoted to the greatest possible extent; Systems for heat treatment of make-up water were implemented in less than three months; The project was carried out in close Danish-Russian co-operation from the beginning of engineering to the commissioning and resulted in transfer and demonstration of know-how and technology; Information was recorded on the existing domestic water and heat supply systems as well as on the treatment of sewage, and recommendations for rehabilitation projects were made. Previously, when the temperature in the district heating system was relatively high, a heat treatment apparently took place in the district heating system. However, due to the current poor economic situation there are no means with which to buy the fuel quantities necessary to maintain the previously normal district heating temperature. In the new concept the cold make-up water is heated to >80 deg. C as required by the health authorities before it is led to the district heating return system and subsequently heated to the actual supply temperature of 50-60 deg. C. The energy consumption in the two concepts is approximately the same. A 1,000 m{sup 3} tank with heating coils was erected between the make-up water system and the district heating system. The tank should equalise the daily capacity

  4. Firewood supply

    International Nuclear Information System (INIS)

    Kaufmann, G.

    1992-01-01

    The use of wood shavings as a heating material in Switzerland is promoted. The processing possibilities of wood used for this purpose and its efficiency are discussed. Concrete proposals are put forward. figs., refs., 23 tabs

  5. Techno-economic study of a distributed hybrid renewable energy system supplying electrical power and heat for a rural house in China

    Science.gov (United States)

    Yuan, Jindou; Xu, Jinliang; Wang, Yaodong

    2018-03-01

    Energy saving and emission reduction have become targets for modern society due to the potential energy crisis and the threat of climate change. A distributed hybrid renewable energy system (HRES) consists of photovoltaic (PV) arrays, a wood-syngas combined heat and power generator (CHP) and back-up batteries is designed to power a typical semi-detached rural house in China which aims to meet the energy demand of a house and to reduce greenhouse gas emissions from the use of fossil fuels. Based on the annual load information of the house and the local meteorological data including solar radiation, air temperature, etc., a system model is set up using HOMER software and is used to simulate all practical configurations to carry out technical and economic evaluations. The performance of the whole HRES system and each component under different configurations are evaluated. The optimized configuration of the system is found

  6. The Potential of Combined Heat and Power Generation, Wind Power Generation and Load Management Techniques for Cost Reduction in Small Electricity Supply Systems.

    Science.gov (United States)

    Bass, Jeremy Hugh

    Available from UMI in association with The British Library. Requires signed TDF. An evaluation is made of the potential fuel and financial savings possible when a small, autonomous diesel system sized to meet the demands of an individual, domestic consumer is adapted to include: (1) combined heat and power (CHP) generation, (2) wind turbine generation, (3) direct load control. The potential of these three areas is investigated by means of time-step simulation modelling on a microcomputer. Models are used to evaluate performance and a Net Present Value analysis used to assess costs. A cost/benefit analysis then enables those areas, or combination of areas, that facilitate and greatest savings to be identified. The modelling work is supported by experience gained from the following: (1) field study of the Lundy Island wind/diesel system, (2) laboratory testing of a small diesel generator set, (3) study of a diesel based CHP unit, (4) study of a diesel based direct load control system, (5) statistical analysis of data obtained from the long-term monitoring of a large number of individual household's electricity consumption. Rather than consider the consumer's electrical demand in isolation, a more flexible approach is adopted, with consumer demand being regarded as the sum of primarily two components: a small, electricity demand for essential services and a large, reschedulable demand for heating/cooling. The results of the study indicate that: (1) operating a diesel set in a CHP mode is the best strategy for both financial and fuel savings. A simple retrofit enables overall conversion efficiencies to be increased from 25% to 60%, or greater, at little cost. (2) wind turbine generation in association with direct load control is a most effective combination. (3) a combination of both the above areas enables greatest overall financial savings, in favourable winds resulting in unit energy costs around 20% of those of diesel only operation.

  7. Alternatives for power supply to natural-gas export compressors combined with heat production evaluated with respect to exergy utilization and CO2 emissions

    International Nuclear Information System (INIS)

    Woelneberg, Pia W.; Ertesvaag, Ivar S.

    2008-01-01

    The supply of process steam in combination with power for natural-gas export compressors was investigated using exergy analysis. The existing system with three 12.32 MW direct drive gas turbines each with a HRSG delivering 19.2 kg/s high-pressure steam was compared with an alternative where the gas turbines were replaced with new turbines. The exergy efficiencies were 46.7% and 48.6%, respectively, for the two cases. A second alternative with electric motors and a new CHP was investigated in three variants, all with some surplus electricity production. All variants gave higher exergy efficiencies than the other alternatives, from 51.5% to 53.6%. A third alternative with electric motors, stand-alone boilers and purchase of electricity was also analyzed, considering different origins of the electricity. This alternative gave the lowest exergy efficiencies, from 37.1% to 41.4% for different variants. In accordance with the exergy utilization, the CO 2 emissions per unit of exergy delivered were the lowest for the second alternative, while the total emissions were the highest for the third alternative. However, the domestic emissions, important in relation to international CO 2 agreements, were shown to be the lowest for the stand-alone boiler in combination with imported electricity. (author)

  8. Design of serially connected district heating heat pumps utilising a geothermal heat source

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    The design of two heat pumps (HP), connected in series, was investigated for operation in the district heating (DH) network of the Greater Copenhagen area, Denmark. The installation was dimensioned to supply 7.2 MW of heat at a temperature of 85 °C. The heat pumps utilise a geothermal heat source...

  9. Managing municipal infrastructure assets

    CSIR Research Space (South Africa)

    Wall, K

    2006-01-01

    Full Text Available into the legislative, regulatory, institutional, financial, technological, human resources and other changes that are no doubt required. Part of this national strategy must be a skills plan to ensure the long-term supply of technically trained human resources....

  10. Simplified mathematical model for heat supply and removal with allowance for chemical reaction kinetics in the N2O4 reversible 2NO2 reversible 2NO + O2 system

    International Nuclear Information System (INIS)

    Shiryaeva, N.M.

    1977-01-01

    The processes of heat supply and removal with chemical reactions proceeding in the circuit are usually described by a set of nonlinear ordinary differential equations. Considering a non-equilibrium state of a chemically reacting gas relative to equilibrium, to which the nonequilibrium system approaches according to a certain process and applying the Tailor series expansion near this equilibrium point, a set of differential equations can be reduced to one differential and some algebraic equations. The analysis shows that of the differential equation obtained can be quasilinearized, and then the linear differential equation can be solved. On the basis of the analytical solutions obtained the calculations of flow parameters have been performed for the cases of cooling and heating the dissociating coolant in channels of a constant cross-section at various pressures. The calculation results are in a satisfactory agreement with the numerical solution of a set of differential equations performed on the ''Minsk-22'' computer. The solution may be applied to calculate isobaric processes in thermodynamic cycles, where the N 2 O 4 coolant is used

  11. Fiscal 1974 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for large buildings); 1974 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu. Ogata kenchikubutsuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-05-28

    Large buildings such as government office building, private office building and gymnasium are consuming a huge amount of fossil fuel as energy for cooling/heating and hot water supply. The final target of this project is a use of solar heat as energy for such systems in place of fossil fuel. The fiscal 1974 target of this project is as follows. The main part of the computation program was developed for system analysis on the whole thermal system composed of building structure, thermal load, and cooling and heating equipment. The small experimental thermal equipment and artificial light source were prepared to clarify the mechanism of solar heat collectors experimentally. As the first step of innovative refrigerator development, the small trial experimental equipment was prepared to clarify heat transfer characteristics for coolant recycling, and to develop an ideal structure heat exchanger possible to reduce the temperature difference between heating medium and heated liquid. Prior to development of a heat storage equipment, basic study was made on heat storage materials, heat insulation methods and characteristics of heat storage tanks. (NEDO)

  12. Conversion to biofuel based heating systems - local environmental effects

    International Nuclear Information System (INIS)

    Jonsson, Anna

    2003-01-01

    One of the most serious environmental problems today is the global warming, i.e.climate changes caused by emissions of greenhouse gases. The greenhouse gases originate from combustion of fossil fuels and changes the atmospheric composition. As a result of the climate change, the Swedish government has decided to make a changeover of the Swedish energy system. This involves an increase of the supply of electricity and heating from renewable energy sources and a decrease in the amount electricity used for heating, as well as a more efficient use of the existing electricity system. Today, a rather large amount electricity is used for heating in Sweden. Furthermore, nuclear power will be phased out by the year 2010 in Sweden. Bio fuels are a renewable energy source and a conceivable alternative to the use of fossil fuels. Therefore, an increase of bio fuels will be seen the coming years. Bio fuels have a lot of environmental advantages, mainly for the global environment, but might also cause negative impacts such as depletion of the soils where the biomass is grown and local deterioration of the air quality where the bio fuels are combusted. These negative impacts are a result of the use of wrong techniques and a lack of knowledge and these factors have to be improved if the increase of the use of bio fuels is to be made effectively. The aim of this master thesis is to evaluate the possibilities for heating with bio fuel based systems in housing areas in the municipalities of Trollhaettan, Ulricehamn and Goetene in Vaestra Goetalands County in the South West of Sweden and to investigate which environmental and health effects are caused by the conversion of heating systems. The objective is to use the case studies as examples on preferable bio fuel based heating systems in different areas, and to what environmental impact this conversion of heating systems might cause. The housing areas for this study have been chosen on the basis of present heating system, one area

  13. Local climate activities in co-operation between municipality, civil society and science shop

    DEFF Research Database (Denmark)

    Jørgensen, Michael Søgaard

    The Science Shop at DTU co-operates with the local municipal administration and the local branch of an environmental NGO about climate change. The co-operation was initiated by a proposal to the Science Shop from the municipal administration. Since the Science Shop requests civil society...... involvement in projects it was proposed to involve the local branch of the environmental NGO. The starting point was topics developed by the administration and the NGO together and announced to students as part of the Science Shop project supply. The focus is climate impact of local activities and strategies...... are initiated and co-ordinated by a group with members from municipal administration, the local NGO and the Science Shop. All projects have involved student projects, but most projects have also contributed to ongoing research activities. The projects up till now have focused on the municipal food supply...

  14. Cianobactérias em mananciais utilizados por sistemas autônomos de abastecimento de água e esgoto (saae de municípios da Zona Mata Sul de Pernambuco| Cyanobacteria in water sources used for autonomous systems of water supply and sewerage (saae in municipalities of the Forest Zone South of Pernambuco

    Directory of Open Access Journals (Sweden)

    Catarina Paula da Silva Ramos

    2016-02-01

    the alteration of organoleptic properties causing changes in taste and odor of water supply. In addition, this phenomenon produces toxins that can generate consequences for human health. In Brazil, this problem is worsening, and the possibility of cyanotoxin presence has become chronic. This study aimed to present a diagnosis and evaluate the results of analysis of cyanobacterial samples from waters of public supply in municipalities of the forest zone south of Pernambuco monitored by Autonomous Services of Water and Sewage (SAAEs. The study was conducted from November 2011 to December 2014 in the Water Quality Laboratory FUNASA (PE. The results showed the presence of 29 species belonging to 13 families and three subclasses. These included cyanobacteria’s genres producing cyanotoxins, such as Planktothrix, Cylindrospermopsis, alongside others, despite the quantitative analysis being within the limits established by law (99% of the analyzed samples. Furthermore, the study showed the importance of monitoring cyanobacteria in water sources of Pernambuco in order to mitigate potential problems inherent to the enviroment and human and animal health.

  15. Electric energy management - basis for a municipal public politics; Gestao da energia eletrica - bases para uma politica publica municipal

    Energy Technology Data Exchange (ETDEWEB)

    Kurahassi, Luiz Fernando

    2006-07-01

    Electricity is an input whose impact on the costs of the municipal public services varies according to the manner it is used and to the way it is obtained from the supplying company. The management of its use results in savings and in greater efficiency and quality of the delivered services - including the public lighting - besides, it softens environmental impacts and develops actions to orientate society towards energy-efficient consumption habits. The public sector has a significant share in the electricity final consumption in Brazil, trending to increase, but a room for consumption reduction and increase in energy efficiency can be seen in the municipalities. The purpose of this thesis is to identify concepts and set parameters that can be the basis of a public policy on electrical power management at the ambit of municipality. This paper reports a series of theoretical studies and empirical researches concerning the efficient use of electrical power in public services in cities of different countries and analyses the results reached from the application of models that successively work in the reality of cities from the Sao Paulo metropolitan area. It concludes that the municipality must play a role much more relevant than being a simple institutional electricity consumer, by proposing the basis for an intervention in the municipal reality. (author)

  16. Transforming your Municipal Electric Utility

    International Nuclear Information System (INIS)

    Harper, P.

    1999-01-01

    A series of overhead viewgraphs accompanied this presentation which focused on what municipalities should and can do to prepare for a competitive energy market in Ontario. Particular attention was given to business strategies, restructuring and transformation of the Municipal Electric Utilities (MEU). Issues and questions regarding ownership were also discussed. Each municipality will have to decide what is the most appropriate governance and organizational structure for their MEU. It was noted that one of the most contentious areas is refinancing and rate structures. Issues regarding merger or partnering options were also discussed. 1 tab

  17. Strategic Supply

    Science.gov (United States)

    2006-01-01

    leaders as Sears, Limited Brands, DHL, Circuit City, Cingular, Nestle and IKEA (Manugistics, 2006). The Strategic Supply Chain Industry Study Group...inventory turns have increased. Other global customers have also reaped the benefits of the Manugistics software. IKEA , Sweden’s retail icon...turned to Manugistics after a mid-1990s ERP implementation failed to fix their forecasting problems, which gave way to fluctuating inventory levels. IKEA

  18. Teleconnected food supply shocks

    Science.gov (United States)

    Bren d'Amour, Christopher; Wenz, Leonie; Kalkuhl, Matthias; Steckel, Jan Christoph; Creutzig, Felix

    2016-03-01

    The 2008-2010 food crisis might have been a harbinger of fundamental climate-induced food crises with geopolitical implications. Heat-wave-induced yield losses in Russia and resulting export restrictions led to increases in market prices for wheat across the Middle East, likely contributing to the Arab Spring. With ongoing climate change, temperatures and temperature variability will rise, leading to higher uncertainty in yields for major nutritional crops. Here we investigate which countries are most vulnerable to teleconnected supply-shocks, i.e. where diets strongly rely on the import of wheat, maize, or rice, and where a large share of the population is living in poverty. We find that the Middle East is most sensitive to teleconnected supply shocks in wheat, Central America to supply shocks in maize, and Western Africa to supply shocks in rice. Weighing with poverty levels, Sub-Saharan Africa is most affected. Altogether, a simultaneous 10% reduction in exports of wheat, rice, and maize would reduce caloric intake of 55 million people living in poverty by about 5%. Export bans in major producing regions would put up to 200 million people below the poverty line at risk, 90% of which live in Sub-Saharan Africa. Our results suggest that a region-specific combination of national increases in agricultural productivity and diversification of trade partners and diets can effectively decrease future food security risks.

  19. District heating

    International Nuclear Information System (INIS)

    Hansen, L.

    1993-01-01

    The environmental risks and uncertainties of a high-energy future are disturbing and give rise to several reservations concerning the use of fossil fuels. A number of technologies will help to reduce atmospheric pollution. In Denmark special importance is attached to the following: Energy conservation. Efficient energy conversion. Renewable energy sources. District heating, combined production of heat and power. Many agree that district heating (DH), produced by the traditional heat-only plant, and combined heat and power (CHP) have enormous potential when considering thermal efficiency and lowered environmental impacts: The basic technology of each is proven, it would be relatively simple to satisfy a substantial part of the energy demand, and their high efficiencies mean reduced pollution including greenhouse gas emissions. This is especially important in high population density areas - the obviously preferred sites for such energy generation. Compared with individual heating DH can provide a community with an operationally efficient and most often also an economically competitive heat supply. This is particularly true under the circumstances where the DH system is supplied from CHP plants. Their use results in very substantial improvements in overall efficiency. Further environmental improvements arise from the reduced air pollution obtainable in reasonably large CHP plants equipped with flue gas cleaning to remove particles, sulphur dioxide, and nitrogen acids. As a consequence of these considerations, DH plays an important role in fulfilling the space and water heating demand in many countries. This is especially the case in Denmark where this technology is utilised to a very great extent. Indeed, DH is one of the reasons why Denmark has relatively good air quality in the cities. (au)

  20. Ultraviolet disinfection of treated municipal wastewaters

    Energy Technology Data Exchange (ETDEWEB)

    Vander Laan, H; Cairns, B

    1993-12-31

    A wastewater disinfection system developed by a Canadian company, Trojan Technologies Inc., was discussed. Disinfection for pathogen reduction prior to discharge of treated municipal wastewater back into rivers and lakes has been either ignored or treated by the use of chemicals. In 1979 the first pilot ultraviolet (UV) wastewater disinfection system was established. Since then, over 500 municipal UV installations have been commissioned. The largest installation can process 212 million gallons of water per day. The advantages of UV as a disinfectant are: (1) It is more effective than chlorine. (2) There are no mutagenic/carcinogenic byproducts formed with UV. (3) No toxic chemical residuals are discharged. (4) UV is safe to both the operators and the public. (5) It is cost effective. Europe has not been as active in wastewater disinfection as has North America. One result of the absence of wastewater disinfection in Europe is that the Rhine River, for example, carries 50 million salmonella per second. Disinfection of wastewater effluents is, of course, indispensable in protecting our drinking water supply. 2 figs.